Sample records for complete positive operator-valued

  1. Absolute continuity for operator valued completely positive maps on C∗-algebras

    NASA Astrophysics Data System (ADS)

    Gheondea, Aurelian; Kavruk, Ali Şamil

    2009-02-01

    Motivated by applicability to quantum operations, quantum information, and quantum probability, we investigate the notion of absolute continuity for operator valued completely positive maps on C∗-algebras, previously introduced by Parthasarathy [in Athens Conference on Applied Probability and Time Series Analysis I (Springer-Verlag, Berlin, 1996), pp. 34-54]. We obtain an intrinsic definition of absolute continuity, we show that the Lebesgue decomposition defined by Parthasarathy is the maximal one among all other Lebesgue-type decompositions and that this maximal Lebesgue decomposition does not depend on the jointly dominating completely positive map, we obtain more flexible formulas for calculating the maximal Lebesgue decomposition, and we point out the nonuniqueness of the Lebesgue decomposition as well as a sufficient condition for uniqueness. In addition, we consider Radon-Nikodym derivatives for absolutely continuous completely positive maps that, in general, are unbounded positive self-adjoint operators affiliated to a certain von Neumann algebra, and we obtain a spectral approximation by bounded Radon-Nikodym derivatives. An application to the existence of the infimum of two completely positive maps is indicated, and formulas in terms of Choi's matrices for the Lebesgue decomposition of completely positive maps in matrix algebras are obtained.

  2. Two new constructions of approximately SIC-POVMs from multiplicative characters

    NASA Astrophysics Data System (ADS)

    Luo, Gaojun; Cao, Xiwang

    2017-12-01

    In quantum information theory, symmetric informationally complete positive operator-valued measures (SIC-POVMs) are relevant to quantum state tomography [8], quantum cryptography [15], and foundational studies [16]. In general, it is hard to construct SIC-POVMs and only a few classes of them existed, as we know. Moreover, we do not know whether there exists an infinite class of them. Many researchers tried to construct approximately symmetric informationally complete positive operator-valued measures (ASIC-POVMs). In this paper, we propose two new constructions of ASIC-POVMs for prime power dimensions only by using multiplicative characters over finite fields.

  3. Algebraic function operator expectation value based quantum eigenstate determination: A case of twisted or bent Hamiltonian, or, a spatially univariate quantum system on a curved space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baykara, N. A.

    Recent studies on quantum evolutionary problems in Demiralp’s group have arrived at a stage where the construction of an expectation value formula for a given algebraic function operator depending on only position operator becomes possible. It has also been shown that this formula turns into an algebraic recursion amongst some finite number of consecutive elements in a set of expectation values of an appropriately chosen basis set over the natural number powers of the position operator as long as the function under consideration and the system Hamiltonian are both autonomous. This recursion corresponds to a denumerable infinite number of algebraicmore » equations whose solutions can or can not be obtained analytically. This idea is not completely original. There are many recursive relations amongst the expectation values of the natural number powers of position operator. However, those recursions may not be always efficient to get the system energy values and especially the eigenstate wavefunctions. The present approach is somehow improved and generalized form of those expansions. We focus on this issue for a specific system where the Hamiltonian is defined on the coordinate of a curved space instead of the Cartesian one.« less

  4. Quantum Strategies and Local Operations

    NASA Astrophysics Data System (ADS)

    Gutoski, Gus

    2010-02-01

    This thesis is divided into two parts. In Part I we introduce a new formalism for quantum strategies, which specify the actions of one party in any multi-party interaction involving the exchange of multiple quantum messages among the parties. This formalism associates with each strategy a single positive semidefinite operator acting only upon the tensor product of the input and output message spaces for the strategy. We establish three fundamental properties of this new representation for quantum strategies and we list several applications, including a quantum version of von Neumann's celebrated 1928 Min-Max Theorem for zero-sum games and an efficient algorithm for computing the value of such a game. In Part II we establish several properties of a class of quantum operations that can be implemented locally with shared quantum entanglement or classical randomness. In particular, we establish the existence of a ball of local operations with shared randomness lying within the space spanned by the no-signaling operations and centred at the completely noisy channel. The existence of this ball is employed to prove that the weak membership problem for local operations with shared entanglement is strongly NP-hard. We also provide characterizations of local operations in terms of linear functionals that are positive and "completely" positive on a certain cone of Hermitian operators, under a natural notion of complete positivity appropriate to that cone. We end the thesis with a discussion of the properties of no-signaling quantum operations.

  5. Phase-space representations of symmetric informationally complete positive-operator-valued-measure fiducial states

    NASA Astrophysics Data System (ADS)

    Saraceno, Marcos; Ermann, Leonardo; Cormick, Cecilia

    2017-03-01

    The problem of finding symmetric informationally complete positive-operator-valued-measures (SIC-POVMs) has been solved numerically for all dimensions d up to 67 [A. J. Scott and M. Grassl, J. Math. Phys. 51, 042203 (2010), 10.1063/1.3374022], but a general proof of existence is still lacking. For each dimension, it was shown that it is possible to find a SIC-POVM that is generated from a fiducial state upon application of the operators of the Heisenberg-Weyl group. We draw on the numerically determined fiducial states to study their phase-space features, as displayed by the characteristic function and the Wigner, Bargmann, and Husimi representations, adapted to a Hilbert space of finite dimension. We analyze the phase-space localization of fiducial states, and observe that the SIC-POVM condition is equivalent to a maximal delocalization property. Finally, we explore the consequences in phase space of the conjectured Zauner symmetry. In particular, we construct a Hermitian operator commuting with this symmetry that leads to a representation of fiducial states in terms of eigenfunctions with definite semiclassical features.

  6. On approximately symmetric informationally complete positive operator-valued measures and related systems of quantum states

    NASA Astrophysics Data System (ADS)

    Klappenecker, Andreas; Rötteler, Martin; Shparlinski, Igor E.; Winterhof, Arne

    2005-08-01

    We address the problem of constructing positive operator-valued measures (POVMs) in finite dimension n consisting of n2 operators of rank one which have an inner product close to uniform. This is motivated by the related question of constructing symmetric informationally complete POVMs (SIC-POVMs) for which the inner products are perfectly uniform. However, SIC-POVMs are notoriously hard to construct and, despite some success of constructing them numerically, there is no analytic construction known. We present two constructions of approximate versions of SIC-POVMs, where a small deviation from uniformity of the inner products is allowed. The first construction is based on selecting vectors from a maximal collection of mutually unbiased bases and works whenever the dimension of the system is a prime power. The second construction is based on perturbing the matrix elements of a subset of mutually unbiased bases. Moreover, we construct vector systems in Cn which are almost orthogonal and which might turn out to be useful for quantum computation. Our constructions are based on results of analytic number theory.

  7. Operating characteristics of depression and anxiety disorder phenotype dimensions and trait neuroticism: a theoretical examination of the fear and distress disorders from the Netherlands study of depression and anxiety.

    PubMed

    Tully, Phillip J; Wardenaar, Klaas J; Penninx, Brenda W J H

    2015-03-15

    The receiver operating characteristics (ROC) of anhedonic depression and anxious arousal to detect the distress- (major depression, dysthymia, generalized anxiety disorder) and fear-disorder clusters (i.e. panic disorder, agoraphobia, social phobia) have not been reported in a large sample. A sample of 2981 persons underwent structured psychiatric interview; n=652 were without lifetime depression and anxiety disorder history. Participants also completed a neuroticism scale (Revised NEO Five Factor Inventory [NEO-FFI]), and the 30-item short adaptation of the Mood and Anxiety Symptoms Questionnaire (MASQ-D30) measuring anhedonic depression, anxious arousal and general distress. Maximal sensitivity and specificity was determined by the Youden Index and the area-under-the-curve (AUC) in ROC analysis. A total of 2624 completed all measures (age M=42.4 years±13.1, 1760 females [67.1%]), including 1060 (40.4%) persons who met criteria for a distress-disorder, and 973 (37.1%) who met criteria for a fear-disorder. The general distress dimension provided the highest ROC values in the detection of the distress-disorders (AUC=.814, sensitivity=71.95%, specificity=76.34%, positive predictive value=67.33, negative predictive value=80.07). None of the measures provided suitable operating characteristics in the detection of the fear-disorders with specificity values <75%. Over sampling of depression and anxiety disorders may lead to inflated positive- and negative predictive values. The MASQ-D30 general distress dimension showed clinically suitable operating characteristics in the detection of distress-disorders. Neither neuroticism nor the MASQ-D30 dimensions provided suitable operating characteristics in the detection of the fear-disorders. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Experimental scheme for qubit and qutrit symmetric informationally complete positive operator-valued measurements using multiport devices

    NASA Astrophysics Data System (ADS)

    Tabia, Gelo Noel M.

    2012-12-01

    It is crucial for various quantum information processing tasks that the state of a quantum system can be determined reliably and efficiently from general quantum measurements. One important class of measurements for this purpose is symmetric informationally complete positive operator-valued measurements (SIC-POVMs). SIC-POVMs have the advantage of providing an unbiased estimator for the quantum state with the minimal number of outcomes needed for full tomography. By virtue of Naimark's dilation theorem, any POVM can always be realized with a suitable coupling between the system and an auxiliary system and by performing a projective measurement on the joint system. In practice, finding the appropriate coupling is rather nontrivial. Here we propose an experimental design for directly implementing SIC-POVMs using multiport devices and path-encoded qubits and qutrits, the utility of which has recently been demonstrated by several experimental groups around the world. Furthermore, we describe how these multiports can be attained in practice with an integrated photonic system composed of nested linear optical elements.

  9. Value of water-soluble contrast (meglumine amidotrizoate) in the diagnosis and management of small bowel obstruction.

    PubMed

    Al Salamah, Saleh Moh'd Al; Fahim, Fraz; Mirza, Shaukat Mahmood

    2006-07-01

    The object of the present study was to determine the effectiveness of a water-soluble contrast follow-through study for differentiating complete from incomplete small bowel obstruction (SBO) and for predicting the need for surgery. This prospective study was conducted at Riyadh Medical Complex, Saudi Arabia and spanned 2 years. All adult patients admitted with SBO were included, except those with obstructed hernias, peritonitis, or postabdominal irradiation. The initial resuscitation meglumine amidotrizoate (Gastrografin) follow-though was performed and was considered positive for complete obstruction if the contrast failed to reach the colon as shown on the 24-hour film. Patients were operated on only if they developed signs of strangulation or failed to improve within 48 hours. Our study group consisted of 73 patients, 48 (65.7%) of whom were male. The mean age was 35.70+/-12.65 years. In 60 (82.2%) patients, contrast reached the ascending colon within 24 hours, giving a definitive diagnosis of incomplete obstruction; among these 60 cases, 49 (81.7%) resolved on conservative management. The other 13 (17.8%) patients were diagnosed as having a complete obstruction; 4 (30.8%) of them were treated conservatively, and 9 (69.2%) underwent surgery. Therefore the sensitivity, specificity, positive predictive value, and negative predictive value for meglumine amidotrizoate follow-through as an indicator for operative treatment of SBO were 45.0, 92.5, 81.7, and 69.2, respectively. The P value using Fisher's exact test was 0.0006. We can confidently diagnose complete and incomplete SBO and differentiate one from the other. This accurate diagnosis indicates a high chance of success with conservative management for incomplete obstruction but does not always correlate with the need for surgical intervention.

  10. Optimal quantum observables

    NASA Astrophysics Data System (ADS)

    Haapasalo, Erkka; Pellonpää, Juha-Pekka

    2017-12-01

    Various forms of optimality for quantum observables described as normalized positive-operator-valued measures (POVMs) are studied in this paper. We give characterizations for observables that determine the values of the measured quantity with probabilistic certainty or a state of the system before or after the measurement. We investigate observables that are free from noise caused by classical post-processing, mixing, or pre-processing of quantum nature. Especially, a complete characterization of pre-processing and post-processing clean observables is given, and necessary and sufficient conditions are imposed on informationally complete POVMs within the set of pure states. We also discuss joint and sequential measurements of optimal quantum observables.

  11. Combination fracturing/gravel-packing completion technique on the Amberjack, Mississippi Canyon 109 field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hannah, R.R.; Park, E.I.; Porter, D.A.

    1994-11-01

    This paper describes a one-step fracturing/gravel-pack (frac-and-pack) completion procedure conducted on the BP Exploration Amberjack platform beginning in early 1992. This platform is 35 miles southwest of Venice, LA. The first four completions on this platform had an average positive skin values of 21. The goal of the frac-and-pack procedure was to reduce these skins to nearly zero. In total, 24 frac-and-pack operations were performed. Details of the fracture design, prefracture testing, fracture design and execution, and production response and a continuing optimization program are discussed. The fractures were performed with the screens in place with the gravel pack aftermore » the fracturing operation. The treatments were designed for the tip screenout technique to create wide fractures and to provide proppant loadings exceeding 8 lbm/ft. This paper presents the trend of the declining skin values, along with a discussion of time-dependent skins. The changes in fluids, breakers, and proppants are also presented. The average skin on 14 frac-and-pack completions was 5.3. The average skin on the final eight completions was 0.2.« less

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finkelstein, J.

    I construct a positive-operator-valued measure (POVM) which has 2d rank-1 elements and which is informationally complete for generic pure states in d dimensions, thus confirming a conjecture made by Flammia, Silberfarb, and Caves (e-print quant-ph/0404137). I show that if a rank-1 POVM is required to be informationally complete for all pure states in d dimensions, it must have at least 3d-2 elements. I also show that, in a POVM which is informationally complete for all pure states in d dimensions, for any vector there must be at least 2d-1 POVM elements which do not annihilate that vector.

  13. Improved separability criteria via some classes of measurements

    NASA Astrophysics Data System (ADS)

    Shen, Shu-Qian; Li, Ming; Li-Jost, Xianqing; Fei, Shao-Ming

    2018-05-01

    The entanglement detection via local measurements can be experimentally implemented. Based on mutually unbiased measurements and general symmetric informationally complete positive-operator-valued measures, we present separability criteria for bipartite quantum states, which, by theoretical analysis, are stronger than the related existing criteria via these measurements. Two detailed examples are supplemented to show the efficiency of the presented separability criteria.

  14. Fibonacci-Lucas SIC-POVMs

    NASA Astrophysics Data System (ADS)

    Grassl, Markus; Scott, Andrew J.

    2017-12-01

    We present a conjectured family of symmetric informationally complete positive operator valued measures which have an additional symmetry group whose size is growing with the dimension. The symmetry group is related to Fibonacci numbers, while the dimension is related to Lucas numbers. The conjecture is supported by exact solutions for dimensions d = 4, 8, 19, 48, 124, and 323 as well as a numerical solution for dimension d = 844.

  15. Measuring Non-Market Values for Hydropower Production and Water Storage on the Colorado River: A White Paper Investigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lowry, Thomas Stephen; Chermak, Janie M.; Brookshire, David S.

    This study presents a conceptual framework for capturing the spatial and temporal aspects of non-market dimensions of value (DOV) and how they vary as the result of policy changes for hydropower generation and developed water uses. The foundation of this project is a literature review that reveals that focused, sector specific valuations are no longer adequate if the goal is to provide decision makers with a complete understanding of their decisions. Rather, estimates of non-market values for informing decisions regarding dam operations and/or other water management alternatives must consider the entire spectrum of market and non-market values, and the tradeoffsmore » (both positive and negative) between those values over time and space, while considering shifting preferences in an uncertain environment. This document describes the history and reasoning for these conclusions and presents a conceptual framework for understanding non-market values as a function of changes to hydropower operations and water resources management.« less

  16. Minimally invasive positioning robot system of femoral neck hollow screw implants based on x-ray error correction

    NASA Astrophysics Data System (ADS)

    Zou, Yunpeng; Xu, Ying; Hu, Lei; Guo, Na; Wang, Lifeng

    2017-01-01

    Aiming the high failure rate, the high radiation quantity and the poor positioning accuracy of femoral neck traditional surgery, this article develops a set of new positioning robot system of femoral neck hollow screw implants based on X-rays error correction, which bases on the study of x-rays perspective principle and the Motion Principle of 6 DOF(degree of freedom) series robot UR(Universal Robots). Compared with Computer Assisted Navigation System, this system owns better positioning accuracy and more simple operation. In addition, without extra Equipment of Visual Tracking, this system can reduce a lot of cost. During the surgery, Doctor can plan the operation path and the pose of mark needle according to the positive and lateral X-rays images of patients. Then they can calculate the pixel ratio according to the ratio of the actual length of mark line and the length on image. After that, they can calculate the amount of exercise of UR Robot according to the relative position between operation path and guide pin and the fixed relationship between guide pin and UR robot. Then, they can control UR to drive the positioning guide pin to the operation path. At this point, check the positioning guide pin and the planning path is coincident, if not, repeat the previous steps, until the positioning guide pin and the planning path coincide which will eventually complete the positioning operation. Moreover, to verify the positioning accuracy, this paper make an errors analysis aiming to thirty cases of the experimental model of bone. The result shows that the motion accuracy of the UR Robot is 0.15mm and the Integral error precision is within 0.8mm. To verify the clinical feasibility of this system, this article analysis on three cases of the clinical experiment. In the whole process of positioning, the X-rays irradiation time is 2-3s, the number of perspective is 3-5 and the whole positioning time is 7-10min. The result shows that this system can complete accurately femoral neck positioning surgery. Meanwhile, it can greatly reduce the X-rays radiation of medical staff and patients. To summarize, it has a significant value in clinical application.

  17. Non-operative management is superior to surgical stabilization in spine injury patients with complete neurological deficits: A perspective study from a developing world country, Pakistan

    PubMed Central

    Shamim, Muhammad Shahzad; Ali, Syed Faizan; Enam, Syed Ather

    2011-01-01

    Background: Surgical stabilization of injured spine in patients with complete spinal cord injury is a common practice despite the lack of strong evidence supporting it. The aim of this study is to compare clinical outcomes and cost-effectiveness of surgical stabilization versus conservative management of spinal injury in patients with complete deficits, essentially from a developing country's point of view. Methods: A detailed analysis of patients with traumatic spine injury and complete deficits admitted at the Aga Khan University Hospital, Pakistan, from January 2004 till January 2010 was carried out. All patients presenting within 14 days of injury were divided in two groups, those who underwent stabilization procedures and those who were managed non-operatively. The two groups were compared with the endpoints being time to rehabilitation, length of hospital stay, 30 day morbidity/mortality, cost of treatment, and status at follow up. Results: Fifty-four patients fulfilled the inclusion criteria and half of these were operated. On comparing endpoints, patients in the operative group took longer time to rehabilitation (P-value = 0.002); had longer hospital stay (P-value = 0.006) which included longer length of stay in special care unit (P-value = 0.002) as well as intensive care unit (P-value = 0.004); and were associated with more complications, especially those related to infections (P-value = 0.002). The mean cost of treatment was also significantly higher in the operative group (USD 6,500) as compared to non-operative group (USD 1490) (P-value < 0.001). Conclusion: We recommend that patients with complete SCI should be managed non-operatively with a provision of surgery only if their rehabilitation is impeded due to pain or deformity. PMID:22145085

  18. Non-operative management is superior to surgical stabilization in spine injury patients with complete neurological deficits: A perspective study from a developing world country, Pakistan.

    PubMed

    Shamim, Muhammad Shahzad; Ali, Syed Faizan; Enam, Syed Ather

    2011-01-01

    Surgical stabilization of injured spine in patients with complete spinal cord injury is a common practice despite the lack of strong evidence supporting it. The aim of this study is to compare clinical outcomes and cost-effectiveness of surgical stabilization versus conservative management of spinal injury in patients with complete deficits, essentially from a developing country's point of view. A detailed analysis of patients with traumatic spine injury and complete deficits admitted at the Aga Khan University Hospital, Pakistan, from January 2004 till January 2010 was carried out. All patients presenting within 14 days of injury were divided in two groups, those who underwent stabilization procedures and those who were managed non-operatively. The two groups were compared with the endpoints being time to rehabilitation, length of hospital stay, 30 day morbidity/mortality, cost of treatment, and status at follow up. Fifty-four patients fulfilled the inclusion criteria and half of these were operated. On comparing endpoints, patients in the operative group took longer time to rehabilitation (P-value = 0.002); had longer hospital stay (P-value = 0.006) which included longer length of stay in special care unit (P-value = 0.002) as well as intensive care unit (P-value = 0.004); and were associated with more complications, especially those related to infections (P-value = 0.002). The mean cost of treatment was also significantly higher in the operative group (USD 6,500) as compared to non-operative group (USD 1490) (P-value < 0.001). We recommend that patients with complete SCI should be managed non-operatively with a provision of surgery only if their rehabilitation is impeded due to pain or deformity.

  19. Recovery of shoulder strength and proprioception after open surgery for recurrent anterior instability: a comparison of two surgical techniques.

    PubMed

    Rokito, Andrew S; Birdzell, Maureen Gallagher; Cuomo, Frances; Di Paola, Matthew J; Zuckerman, Joseph D

    2010-06-01

    Previous studies have documented a decrease in proprioceptive capacity in the unstable shoulder. The degree to which surgical approach affects recovery of strength and proprioception is unknown. The recovery of strength and proprioception after open surgery for recurrent anterior glenohumeral instability was compared for 2 surgical procedures. A prospective analysis of 55 consecutive patients with posttraumatic unilateral recurrent anterior glenohumeral instability was performed. Thirty patients (group 1) underwent an open inferior capsular shift with detachment of the subscapularis, and 25 (group 2) underwent an anterior capsulolabral reconstruction. Mean preoperative proprioception and strength values were significantly lower for the affected shoulders in both groups. At 6 months after surgery, there were no significant differences for mean strength and proprioception values between the unaffected and operative sides for group 2 patients. In group 1 patients, however, there were still significant deficits in mean position sense and strength values. Complete restoration of proprioception and strength, however, was evident by 12 months in group 1. This study demonstrates that there are significant deficits in both strength and proprioception in patients with posttraumatic, recurrent anterior glenohumeral instability. Although both are completely restored by 1 year after surgery, a subscapularis-splitting approach allows for complete recovery of strength and position sense as early as 6 months postoperatively. Detachment of the subscapularis delays recovery of strength and position sense for up to 12 months after surgery. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  20. A classification of open Gaussian dynamics

    NASA Astrophysics Data System (ADS)

    Grimmer, Daniel; Brown, Eric; Kempf, Achim; Mann, Robert B.; Martín-Martínez, Eduardo

    2018-06-01

    We introduce a classification scheme for the generators of bosonic open Gaussian dynamics, providing instructive diagrams description for each type of dynamics. Using this classification, we discuss the consequences of imposing complete positivity on Gaussian dynamics. In particular, we show that non-symplectic operations must be active to allow for complete positivity. In addition, non-symplectic operations can, in fact, conserve the volume of phase space only if the restriction of complete positivity is lifted. We then discuss the implications for the relationship between information and energy flows in open quantum mechanics.

  1. Spectrally Encoded Confocal Microscopy (SECM) for Diagnosing of Breast Cancer in Excision and Margin Specimens

    PubMed Central

    Brachtel, Elena F.; Johnson, Nicole B.; Huck, Amelia E.; Rice-Stitt, Travis L.; Vangel, Mark G.; Smith, Barbara L.; Tearney, Guillermo J.; Kang, Dongkyun

    2016-01-01

    A large percentage of breast cancer patients treated with breast conserving surgery need to undergo multiple surgeries due to positive margins found during post-operative margin assessment. Carcinomas could be removed completely during the initial surgery and additional surgery avoided if positive margins can be determined intra-operatively. Spectrally-encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technology that has a potential to rapidly image the entire surgical margin at sub-cellular resolution and accurately determine margin status intra-operatively. In this paper, in order to test feasibility of using SECM for intra-operative margin assessment, we have evaluated the diagnostic accuracy of SECM for detecting various types of breast cancers. Forty-six surgically-removed breast specimens were imaged with a SECM system. Side-by-side comparison between SECM and histologic images showed that SECM images can visualize key histomorphologic patterns of normal/benign and malignant breast tissues. Small (500 µm × 500 µm) spatially-registered SECM and histologic images (n=124 for each) were diagnosed independently by three pathologists with expertise in breast pathology. Diagnostic accuracy of SECM for determining malignant tissues was high, average sensitivity of 0.91, specificity of 0.93, positive predictive value of 0.95, and negative predictive value of 0.87. Intra-observer agreement and inter-observer agreement for SECM were also high, 0.87 and 0.84, respectively. Results from this study suggest that SECM may be developed into an intra-operative margin assessment tool for guiding breast cancer excisions. PMID:26779830

  2. Heisenberg's uncertainty principle for simultaneous measurement of positive-operator-valued measures

    NASA Astrophysics Data System (ADS)

    Miyadera, Takayuki; Imai, Hideki

    2008-11-01

    A limitation on simultaneous measurement of two arbitrary positive-operator-valued measures is discussed. In general, simultaneous measurement of two noncommutative observables is only approximately possible. Following Werner’s formulation, we introduce a distance between observables to quantify an accuracy of measurement. We derive an inequality that relates the achievable accuracy with noncommutativity between two observables. As a byproduct a necessary condition for two positive-operator-valued measures to be simultaneously measurable is obtained.

  3. Causal localizations in relativistic quantum mechanics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castrigiano, Domenico P. L., E-mail: castrig@ma.tum.de; Leiseifer, Andreas D., E-mail: andreas.leiseifer@tum.de

    2015-07-15

    Causal localizations describe the position of quantum systems moving not faster than light. They are constructed for the systems with finite spinor dimension. At the center of interest are the massive relativistic systems. For every positive mass, there is the sequence of Dirac tensor-localizations, which provides a complete set of inequivalent irreducible causal localizations. They obey the principle of special relativity and are fully Poincaré covariant. The boosters are determined by the causal position operator and the other Poincaré generators. The localization with minimal spinor dimension is the Dirac localization. Thus, the Dirac equation is derived here as a meremore » consequence of the principle of causality. Moreover, the higher tensor-localizations, not known so far, follow from Dirac’s localization by a simple construction. The probability of localization for positive energy states results to be described by causal positive operator valued (PO-) localizations, which are the traces of the causal localizations on the subspaces of positive energy. These causal Poincaré covariant PO-localizations for every irreducible massive relativistic system were, all the more, not known before. They are shown to be separated. Hence, the positive energy systems can be localized within every open region by a suitable preparation as accurately as desired. Finally, the attempt is made to provide an interpretation of the PO-localization operators within the frame of conventional quantum mechanics attributing an important role to the negative energy states.« less

  4. Causal localizations in relativistic quantum mechanics

    NASA Astrophysics Data System (ADS)

    Castrigiano, Domenico P. L.; Leiseifer, Andreas D.

    2015-07-01

    Causal localizations describe the position of quantum systems moving not faster than light. They are constructed for the systems with finite spinor dimension. At the center of interest are the massive relativistic systems. For every positive mass, there is the sequence of Dirac tensor-localizations, which provides a complete set of inequivalent irreducible causal localizations. They obey the principle of special relativity and are fully Poincaré covariant. The boosters are determined by the causal position operator and the other Poincaré generators. The localization with minimal spinor dimension is the Dirac localization. Thus, the Dirac equation is derived here as a mere consequence of the principle of causality. Moreover, the higher tensor-localizations, not known so far, follow from Dirac's localization by a simple construction. The probability of localization for positive energy states results to be described by causal positive operator valued (PO-) localizations, which are the traces of the causal localizations on the subspaces of positive energy. These causal Poincaré covariant PO-localizations for every irreducible massive relativistic system were, all the more, not known before. They are shown to be separated. Hence, the positive energy systems can be localized within every open region by a suitable preparation as accurately as desired. Finally, the attempt is made to provide an interpretation of the PO-localization operators within the frame of conventional quantum mechanics attributing an important role to the negative energy states.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demkowicz-Dobrzanski, Rafal; Lewenstein, Maciej; Institut fuer Theoretische Physik, Universitaet Hannover, D-30167 Hannover

    We solve the problem of the optimal cloning of pure entangled two-qubit states with a fixed degree of entanglement using local operations and classical communication. We show that, amazingly, classical communication between the parties can improve the fidelity of local cloning if and only if the initial entanglement is higher than a certain critical value. It is completely useless for weakly entangled states. We also show that bound entangled states with positive partial transpose are not useful as a resource to improve the best local cloning fidelity.

  6. Effect of Hilbert space truncation on Anderson localization

    NASA Astrophysics Data System (ADS)

    Krishna, Akshay; Bhatt, R. N.

    2018-05-01

    The 1D Anderson model possesses a completely localized spectrum of eigenstates for all values of the disorder. We consider the effect of projecting the Hamiltonian to a truncated Hilbert space, destroying time-reversal symmetry. We analyze the ensuing eigenstates using different measures such as inverse participation ratio and sample-averaged moments of the position operator. In addition, we examine amplitude fluctuations in detail to detect the possibility of multifractal behavior (characteristic of mobility edges) that may arise as a result of the truncation procedure.

  7. Stillwater Hybrid Geo-Solar Power Plant Optimization Analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wendt, Daniel S.; Mines, Gregory L.; Turchi, Craig S.

    2015-09-02

    The Stillwater Power Plant is the first hybrid plant in the world able to bring together a medium-enthalpy geothermal unit with solar thermal and solar photovoltaic systems. Solar field and power plant models have been developed to predict the performance of the Stillwater geothermal / solar-thermal hybrid power plant. The models have been validated using operational data from the Stillwater plant. A preliminary effort to optimize performance of the Stillwater hybrid plant using optical characterization of the solar field has been completed. The Stillwater solar field optical characterization involved measurement of mirror reflectance, mirror slope error, and receiver position error.more » The measurements indicate that the solar field may generate 9% less energy than the design value if an appropriate tracking offset is not employed. A perfect tracking offset algorithm may be able to boost the solar field performance by about 15%. The validated Stillwater hybrid plant models were used to evaluate hybrid plant operating strategies including turbine IGV position optimization, ACC fan speed and turbine IGV position optimization, turbine inlet entropy control using optimization of multiple process variables, and mixed working fluid substitution. The hybrid plant models predict that each of these operating strategies could increase net power generation relative to the baseline Stillwater hybrid plant operations.« less

  8. Ergonomic comparison of operating a built-in touch-pad pointing device and a trackball mouse on posture and muscle activity.

    PubMed

    Lee, Tzu-Hsien

    2005-12-01

    This study examined the effects of operating a built-in touch-pad pointing device and a trackball mouse on participants' completion times, hand positions during operation, postural angles, and muscle activities. 8 young men were asked to perform a cursor travel task on a notebook computer using both 60- and 80-cm high table conditions. Analysis showed that the trackball mouse significantly decreased completion times. Participants selected a hand position farther from the table edge and larger elbow angle for the trackball mouse than for the built-in touch-pad pointing device. Participants' neck, thoracic, and arm angles, or splenius capitis, trapezius, deltoid, and erector spinae muscle activities were not significantly affected by the devices, but table height significantly affected participants' completion times, hand positions, and postural angles.

  9. Quantum channels irreducibly covariant with respect to the finite group generated by the Weyl operators

    NASA Astrophysics Data System (ADS)

    Siudzińska, Katarzyna; Chruściński, Dariusz

    2018-03-01

    In matrix algebras, we introduce a class of linear maps that are irreducibly covariant with respect to the finite group generated by the Weyl operators. In particular, we analyze the irreducibly covariant quantum channels, that is, the completely positive and trace-preserving linear maps. Interestingly, imposing additional symmetries leads to the so-called generalized Pauli channels, which were recently considered in the context of the non-Markovian quantum evolution. Finally, we provide examples of irreducibly covariant positive but not necessarily completely positive maps.

  10. Ambulatory measurement of the scapulohumeral rhythm: intra- and inter-operator agreement of a protocol based on inertial and magnetic sensors.

    PubMed

    Parel, I; Cutti, A G; Fiumana, G; Porcellini, G; Verni, G; Accardo, A P

    2012-04-01

    To measure the scapulohumeral rhythm (SHR) in outpatient settings, the motion analysis protocol named ISEO (INAIL Shoulder and Elbow Outpatient protocol) was developed, based on inertial and magnetic sensors. To complete the sensor-to-segment calibration, ISEO requires the involvement of an operator for sensor placement and for positioning the patient's arm in a predefined posture. Since this can affect the measure, this study aimed at quantifying ISEO intra- and inter-operator agreement. Forty subjects were considered, together with two operators, A and B. Three measurement sessions were completed for each subject: two by A and one by B. In each session, the humerus and scapula rotations were measured during sagittal and scapular plane elevation movements. ISEO intra- and inter-operator agreement were assessed by computing, between sessions, the: (1) similarity of the scapulohumeral patterns through the Coefficient of Multiple Correlation (CMC(2)), both considering and excluding the difference of the initial value of the scapula rotations between two sessions (inter-session offset); (2) 95% Smallest Detectable Difference (SDD(95)) in scapula range of motion. Results for CMC(2) showed that the intra- and inter-operator agreement is acceptable (median≥0.85, lower-whisker ≥ 0.75) for most of the scapula rotations, independently from the movement and the inter-session offset. The only exception is the agreement for scapula protraction-retraction and for scapula medio-lateral rotation during abduction (inter-operator), which is acceptable only if the inter-session offset is removed. SDD(95) values ranged from 4.4° to 8.6° for the inter-operator and between 4.9° and 8.5° for the intra-operator agreement. In conclusion, ISEO presents a high intra- and inter-operator agreement, particularly with the scapula inter-session offset removed. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Fluctuation removal around spectral and temporal constancy limits via use of an extended space expectation value weight function for singular quantum systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalay, Berfin; Demiralp, Metin

    2015-03-10

    This work is a new extension to our a very recent work whose paper will appear in the proceedings of a very recent international conference. What we have done in the previous work is the use of a weight operator to suppress the singularities causing nonexistence of some of temporal Maclaurin expansion coefficients. The weight operator has been constructed in such a way that certain number of expectation values of position operator’s first positive integer powers with and without the chosen weight operator match. Therein this match has not been considered for the momentum operator’s corresponding power expectation values andmore » a finite linear combination of the spatial variable’s first reciprocal powers has been used in the construction of the weight operator. Here, that approach is extended to the case where matches for both position and momentum operators are considered and the weight operator involves finite linear combinations of the spatial variable’s both positive integer powers and their reciprocals.« less

  12. Pure state `really' informationally complete with rank-1 POVM

    NASA Astrophysics Data System (ADS)

    Wang, Yu; Shang, Yun

    2018-03-01

    What is the minimal number of elements in a rank-1 positive operator-valued measure (POVM) which can uniquely determine any pure state in d-dimensional Hilbert space H_d? The known result is that the number is no less than 3d-2. We show that this lower bound is not tight except for d=2 or 4. Then we give an upper bound 4d-3. For d=2, many rank-1 POVMs with four elements can determine any pure states in H_2. For d=3, we show eight is the minimal number by construction. For d=4, the minimal number is in the set of {10,11,12,13}. We show that if this number is greater than 10, an unsettled open problem can be solved that three orthonormal bases cannot distinguish all pure states in H_4. For any dimension d, we construct d+2k-2 adaptive rank-1 positive operators for the reconstruction of any unknown pure state in H_d, where 1≤ k ≤ d.

  13. Intra-Operative Frozen Sections for Ovarian Tumors – A Tertiary Center Experience

    PubMed Central

    Arshad, Nur Zaiti Md; Ng, Beng Kwang; Paiman, Noor Asmaliza Md; Mahdy, Zaleha Abdullah; Noor, Rushdan Mohd

    2018-01-01

    Background: Accuracy of diagnosis with intra-operative frozen sections is extremely important in the evaluation of ovarian tumors so that appropriate surgical procedures can be selected. Study design: All patients who with intra-operative frozen sections for ovarian masses in a tertiary center over nine years from June 2008 until April 2017 were reviewed. Frozen section diagnosis and final histopathological reports were compared. Main outcome measures: Sensitivity, specificity, positive and negative predictive values of intra-operative frozen section as compared to final histopathological results for ovarian tumors. Results: A total of 92 cases were recruited for final evaluation. The frozen section diagnoses were comparable with the final histopathological reports in 83.7% of cases. The sensitivity, specificity, positive predictive value and negative predictive value for benign and malignant ovarian tumors were 95.6%, 85.1%, 86.0% and 95.2% and 69.2%, 100%, 100% and 89.2% respectively. For borderline ovarian tumors, the sensitivity and specificity were 76.2% and 88.7%, respectively; the positive predictive value was 66.7% and the negative predictive value was 92.7%. Conclusion: The accuracy of intra-operative frozen section diagnoses for ovarian tumors is high and this approach remains a reliable option in assessing ovarian masses intra-operatively. PMID:29373916

  14. Evaluating sedimentation problems in activated sludge treatment plants operating at complete sludge retention time.

    PubMed

    Amanatidou, Elisavet; Samiotis, Georgios; Trikoilidou, Eleni; Pekridis, George; Taousanidis, Nikolaos

    2015-02-01

    Zero net sludge growth can be achieved by complete retention of solids in activated sludge wastewater treatment, especially in high strength and biodegradable wastewaters. When increasing the solids retention time, MLSS and MLVSS concentrations reach a plateau phase and observed growth yields values tend to zero (Yobs ≈ 0). In this work, in order to evaluate sedimentation problems arised due to high MLSS concentrations and complete sludge retention operational conditions, two identical innovative slaughterhouse wastewater treatment plants were studied. Measurements of wastewaters' quality characteristics, treatment plant's operational conditions, sludge microscopic analysis and state point analysis were conducted. Results have shown that low COD/Nitrogen ratios increase sludge bulking and flotation phenomena due to accidental denitrification in clarifiers. High return activated sludge rate is essential in complete retention systems as it reduces sludge condensation and hydraulic retention time in the clarifiers. Under certain operational conditions sludge loading rates can greatly exceed literature limit values. The presented methodology is a useful tool for estimation of sedimentation problems encountered in activated sludge wastewater treatment plants with complete retention time. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Validation of the Hospital Anxiety and Depression Scale in patients with epilepsy.

    PubMed

    Wiglusz, Mariusz S; Landowski, Jerzy; Michalak, Lidia; Cubała, Wiesław J

    2016-05-01

    Despite the fact that depressive disorders are the most common comorbidities among patients with epilepsy (PWEs), they often go unrecognized and untreated. The availability of validated screening instruments to detect depression in PWEs is limited. The aim of the present study was to validate the Hospital Anxiety and Depression Scale (HADS) in adult PWEs. A consecutive group of 118 outpatient PWEs was invited to participate in the study. Ninety-six patients met inclusion criteria, completed HADS, and were examined by a trained psychiatrist using Structured Clinical Interview (SCID-I) for DSM-IV-TR. Receiver operating characteristic (ROC) curves were used to determine the optimal threshold scores for the HADS depression subscale (HADS-D). Receiver operating characteristic analyses showed areas under the curve at approximately 84%. For diagnoses of MDD, the HADS-D demonstrated the best psychometric properties for a cutoff score ≥7 with sensitivity of 90.5%, specificity of 70.7%, positive predictive value of 46.3%, and negative predictive value of 96.4%. In the case of the group with 'any depressive disorder', the HADS-D optimum cutoff score was ≥6 with sensitivity of 82.5%, specificity of 73.2%, positive predictive value of 68.8%, and negative predictive value of 85.4%. The HADS-D proved to be a valid and reliable psychometric instrument in terms of screening for depressive disorders in PWEs. In the epilepsy setting, HADS-D maintains adequate sensitivity, acceptable specificity, and high NPV but low PPV for diagnosing MDD with an optimum cutoff score ≥7. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. The utility of the Edmonton Symptom Assessment System in screening for anxiety and depression.

    PubMed

    Bagha, S M; Macedo, A; Jacks, L M; Lo, C; Zimmermann, C; Rodin, G; Li, M

    2013-01-01

    The Edmonton Symptom Assessment System (ESAS) is a common screening tool in cancer, although its validity for distress screening is unproven. Here, screening performance of the ESAS anxiety (ESAS-A) and depression (ESAS-D) items were validated against the anxiety [Generalised Anxiety Disorder-7 (GAD-7)] and depression [Patient Health Questionnaire-9 (PHQ-9)] subscales of the PHQ. A total of 1215 cancer patients completed the Distress Assessment and Response Tool (DART), a computerised distress screening instrument. Spearman's rank correlation coefficients and receiver operating characteristic curve analyses were used to evaluate the ability of ESAS-A and ESAS-D to identify moderate distress (GAD-7/PHQ-9 ≥ 10). Spearman's rank correlation coefficients comparing ESAS-A and ESAS-D with GAD-7 and PHQ-9 were 0.74 and 0.72 respectively. Areas under the receiver operating characteristic curves were 0.89 and 0.88 for anxiety and depression respectively. A cut-off of ≥3 on ESAS-A demonstrated a sensitivity of 0.91, specificity of 0.68, positive predictive value of 0.34 and negative predictive value of 0.97. A cut-off of ≥2 on the ESAS-D demonstrated a sensitivity of 0.86, specificity of 0.72, positive predictive value of 0.46 and negative predictive value of 0.95. High sensitivities of ESAS-A and ESAS-D at certain cut-offs suggest they have use in ruling-out distress. However, their low specificities indicate secondary screening is needed to rule-in anxiety or depression for case-finding. © 2012 Blackwell Publishing Ltd.

  17. Major results from the first plasma campaign of the Wendelstein 7-X stellarator

    DOE PAGES

    Wolf, R. C.; Ali, A.; Alonso, A.; ...

    2017-07-27

    Here, after completing the main construction phase of Wendelstein 7-X (W7-X) and successfully commissioning the device, first plasma operation started at the end of 2015. Integral commissioning of plasma start-up and operation using electron cyclotron resonance heating (ECRH) and an extensive set of plasma diagnostics have been completed, allowing initial physics studies during the first operational campaign. Both in helium and hydrogen, plasma breakdown was easily achieved. Gaining experience with plasma vessel conditioning, discharge lengths could be extended gradually. Eventually, discharges lasted up to 6 s, reaching an injected energy of 4 MJ, which is twice the limit originally agreedmore » for the limiter configuration employed during the first operational campaign. At power levels of 4 MW central electron densities reached 3 × 10 19 m –3, central electron temperatures reached values of 7 keV and ion temperatures reached just above 2 keV. Important physics studies during this first operational phase include a first assessment of power balance and energy confinement, ECRH power deposition experiments, 2nd harmonic O-mode ECRH using multi-pass absorption, and current drive experiments using electron cyclotron current drive. As in many plasma discharges the electron temperature exceeds the ion temperature significantly, these plasmas are governed by core electron root confinement showing a strong positive electric field in the plasma centre.« less

  18. Major results from the first plasma campaign of the Wendelstein 7-X stellarator

    NASA Astrophysics Data System (ADS)

    Wolf, R. C.; Ali, A.; Alonso, A.; Baldzuhn, J.; Beidler, C.; Beurskens, M.; Biedermann, C.; Bosch, H.-S.; Bozhenkov, S.; Brakel, R.; Dinklage, A.; Feng, Y.; Fuchert, G.; Geiger, J.; Grulke, O.; Helander, P.; Hirsch, M.; Höfel, U.; Jakubowski, M.; Knauer, J.; Kocsis, G.; König, R.; Kornejew, P.; Krämer-Flecken, A.; Krychowiak, M.; Landreman, M.; Langenberg, A.; Laqua, H. P.; Lazerson, S.; Maaßberg, H.; Marsen, S.; Marushchenko, M.; Moseev, D.; Niemann, H.; Pablant, N.; Pasch, E.; Rahbarnia, K.; Schlisio, G.; Stange, T.; Pedersen, T. Sunn; Svensson, J.; Szepesi, T.; Trimino Mora, H.; Turkin, Y.; Wauters, T.; Weir, G.; Wenzel, U.; Windisch, T.; Wurden, G.; Zhang, D.; Abramovic, I.; Äkäslompolo, S.; Aleynikov, P.; Aleynikova, K.; Alzbutas, R.; Anda, G.; Andreeva, T.; Ascasibar, E.; Assmann, J.; Baek, S.-G.; Banduch, M.; Barbui, T.; Barlak, M.; Baumann, K.; Behr, W.; Benndorf, A.; Bertuch, O.; Biel, W.; Birus, D.; Blackwell, B.; Blanco, E.; Blatzheim, M.; Bluhm, T.; Böckenhoff, D.; Bolgert, P.; Borchardt, M.; Borsuk, V.; Boscary, J.; Böttger, L.-G.; Brand, H.; Brandt, Ch.; Bräuer, T.; Braune, H.; Brezinsek, S.; Brunner, K.-J.; Brünner, B.; Burhenn, R.; Buttenschön, B.; Bykov, V.; Calvo, I.; Cannas, B.; Cappa, A.; Carls, A.; Carraro, L.; Carvalho, B.; Castejon, F.; Charl, A.; Chernyshev, F.; Cianciosa, M.; Citarella, R.; Ciupiński, Ł.; Claps, G.; Cole, M.; Cole, M. J.; Cordella, F.; Cseh, G.; Czarnecka, A.; Czermak, A.; Czerski, K.; Czerwinski, M.; Czymek, G.; da Molin, A.; da Silva, A.; Dammertz, G.; Danielson, J.; de la Pena, A.; Degenkolbe, S.; Denner, P.; Dhard, D. P.; Dostal, M.; Drevlak, M.; Drewelow, P.; Drews, Ph.; Dudek, A.; Dundulis, G.; Durodie, F.; van Eeten, P.; Effenberg, F.; Ehrke, G.; Endler, M.; Ennis, D.; Erckmann, E.; Esteban, H.; Estrada, T.; Fahrenkamp, N.; Feist, J.-H.; Fellinger, J.; Fernandes, H.; Fietz, W. H.; Figacz, W.; Fontdecaba, J.; Ford, O.; Fornal, T.; Frerichs, H.; Freund, A.; Führer, M.; Funaba, T.; Galkowski, A.; Gantenbein, G.; Gao, Y.; García Regaña, J.; Garcia-Munoz, M.; Gates, D.; Gawlik, G.; Geiger, B.; Giannella, V.; Gierse, N.; Gogoleva, A.; Goncalves, B.; Goriaev, A.; Gradic, D.; Grahl, M.; Green, J.; Grosman, A.; Grote, H.; Gruca, M.; Guerard, C.; Haiduk, L.; Han, X.; Harberts, F.; Harris, J. H.; Hartfuß, H.-J.; Hartmann, D.; Hathiramani, D.; Hein, B.; Heinemann, B.; Heitzenroeder, P.; Henneberg, S.; Hennig, C.; Hernandez Sanchez, J.; Hidalgo, C.; Hölbe, H.; Hollfeld, K. P.; Hölting, A.; Höschen, D.; Houry, M.; Howard, J.; Huang, X.; Huber, M.; Huber, V.; Hunger, H.; Ida, K.; Ilkei, T.; Illy, S.; Israeli, B.; Ivanov, A.; Jablonski, S.; Jagielski, J.; Jelonnek, J.; Jenzsch, H.; Junghans, P.; Kacmarczyk, J.; Kaliatka, T.; Kallmeyer, J.-P.; Kamionka, U.; Karalevicius, R.; Kasahara, H.; Kasparek, W.; Kenmochi, N.; Keunecke, M.; Khilchenko, A.; Kinna, D.; Kleiber, R.; Klinger, T.; Knaup, M.; Kobarg, Th.; Köchl, F.; Kolesnichenko, Y.; Könies, A.; Köppen, M.; Koshurinov, J.; Koslowski, R.; Köster, F.; Koziol, R.; Krämer, M.; Krampitz, R.; Kraszewsk, P.; Krawczyk, N.; Kremeyer, T.; Krings, Th.; Krom, J.; Krzesinski, G.; Ksiazek, I.; Kubkowska, M.; Kühner, G.; Kurki-Suonio, T.; Kwak, S.; Lang, R.; Langish, S.; Laqua, H.; Laube, R.; Lechte, C.; Lennartz, M.; Leonhardt, W.; Lewerentz, L.; Liang, Y.; Linsmeier, Ch.; Liu, S.; Lobsien, J.-F.; Loesser, D.; Loizu Cisquella, J.; Lore, J.; Lorenz, A.; Losert, M.; Lubyako, L.; Lücke, A.; Lumsdaine, A.; Lutsenko, V.; Majano-Brown, J.; Marchuk, O.; Mardenfeld, M.; Marek, P.; Massidda, S.; Masuzaki, S.; Maurer, D.; McCarthy, K.; McNeely, P.; Meier, A.; Mellein, D.; Mendelevitch, B.; Mertens, Ph.; Mikkelsen, D.; Mishchenko, O.; Missal, B.; Mittelstaedt, J.; Mizuuchi, T.; Mollen, A.; Moncada, V.; Mönnich, T.; Morizaki, T.; Munk, R.; Murakami, S.; Musielok, F.; Náfrádi, G.; Nagel, M.; Naujoks, D.; Neilson, H.; Neubauer, O.; Neuner, U.; Ngo, T.; Nocentini, R.; Nührenberg, C.; Nührenberg, J.; Obermayer, S.; Offermanns, G.; Ogawa, K.; Ongena, J.; Oosterbeek, J. W.; Orozco, G.; Otte, M.; Pacios Rodriguez, L.; Pan, W.; Panadero, N.; Panadero Alvarez, N.; Panin, A.; Papenfuß, D.; Paqay, S.; Pavone, A.; Pawelec, E.; Pelka, G.; Peng, X.; Perseo, V.; Peterson, B.; Pieper, A.; Pilopp, D.; Pingel, S.; Pisano, F.; Plaum, B.; Plunk, G.; Povilaitis, M.; Preinhaelter, J.; Proll, J.; Puiatti, M.-E.; Sitjes, A. Puig; Purps, F.; Rack, M.; Récsei, S.; Reiman, A.; Reiter, D.; Remppel, F.; Renard, S.; Riedl, R.; Riemann, J.; Rimkevicius, S.; Riße, K.; Rodatos, A.; Röhlinger, H.; Romé, M.; Rong, P.; Roscher, H.-J.; Roth, B.; Rudischhauser, L.; Rummel, K.; Rummel, T.; Runov, A.; Rust, N.; Ryc, L.; Ryosuke, S.; Sakamoto, R.; Samartsev, A.; Sanchez, M.; Sano, F.; Satake, S.; Satheeswaran, G.; Schacht, J.; Schauer, F.; Scherer, T.; Schlaich, A.; Schlüter, K.-H.; Schmitt, J.; Schmitz, H.; Schmitz, O.; Schmuck, S.; Schneider, M.; Schneider, W.; Scholz, M.; Scholz, P.; Schrittwieser, R.; Schröder, M.; Schröder, T.; Schroeder, R.; Schumacher, H.; Schweer, B.; Shanahan, B.; Shikhovtsev, I. V.; Sibilia, M.; Sinha, P.; Sipliä, S.; Skodzik, J.; Slaby, C.; Smith, H.; Spiess, W.; Spong, D. A.; Spring, A.; Stadler, R.; Standley, B.; Stephey, L.; Stoneking, M.; Stridde, U.; Sulek, Z.; Surko, C.; Suzuki, Y.; Szabó, V.; Szabolics, T.; Szökefalvi-Nagy, Z.; Tamura, N.; Terra, A.; Terry, J.; Thomas, J.; Thomsen, H.; Thumm, M.; von Thun, C. P.; Timmermann, D.; Titus, P.; Toi, K.; Travere, J. M.; Traverso, P.; Tretter, J.; Tsuchiya, H.; Tsujimura, T.; Tulipán, S.; Turnyanskiy, M.; Unterberg, B.; Urban, J.; Urbonavicius, E.; Vakulchyk, I.; Valet, S.; van Millingen, B.; Vela, L.; Velasco, J.-L.; Vergote, M.; Vervier, M.; Vianello, N.; Viebke, H.; Vilbrandt, R.; Vorkörper, A.; Wadle, S.; Wagner, F.; Wang, E.; Wang, N.; Warmer, F.; Wegener, L.; Weggen, J.; Wei, Y.; Wendorf, J.; Werner, A.; Wiegel, B.; Wilde, F.; Winkler, E.; Winters, V.; Wolf, S.; Wolowski, J.; Wright, A.; Xanthopoulos, P.; Yamada, H.; Yamada, I.; Yasuhara, R.; Yokoyama, M.; Zajac, J.; Zarnstorff, M.; Zeitler, A.; Zhang, H.; Zhu, J.; Zilker, M.; Zimbal, A.; Zocco, A.; Zoletnik, S.; Zuin, M.

    2017-10-01

    After completing the main construction phase of Wendelstein 7-X (W7-X) and successfully commissioning the device, first plasma operation started at the end of 2015. Integral commissioning of plasma start-up and operation using electron cyclotron resonance heating (ECRH) and an extensive set of plasma diagnostics have been completed, allowing initial physics studies during the first operational campaign. Both in helium and hydrogen, plasma breakdown was easily achieved. Gaining experience with plasma vessel conditioning, discharge lengths could be extended gradually. Eventually, discharges lasted up to 6 s, reaching an injected energy of 4 MJ, which is twice the limit originally agreed for the limiter configuration employed during the first operational campaign. At power levels of 4 MW central electron densities reached 3  ×  1019 m-3, central electron temperatures reached values of 7 keV and ion temperatures reached just above 2 keV. Important physics studies during this first operational phase include a first assessment of power balance and energy confinement, ECRH power deposition experiments, 2nd harmonic O-mode ECRH using multi-pass absorption, and current drive experiments using electron cyclotron current drive. As in many plasma discharges the electron temperature exceeds the ion temperature significantly, these plasmas are governed by core electron root confinement showing a strong positive electric field in the plasma centre.

  19. Major results from the first plasma campaign of the Wendelstein 7-X stellarator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolf, R. C.; Ali, A.; Alonso, A.

    Here, after completing the main construction phase of Wendelstein 7-X (W7-X) and successfully commissioning the device, first plasma operation started at the end of 2015. Integral commissioning of plasma start-up and operation using electron cyclotron resonance heating (ECRH) and an extensive set of plasma diagnostics have been completed, allowing initial physics studies during the first operational campaign. Both in helium and hydrogen, plasma breakdown was easily achieved. Gaining experience with plasma vessel conditioning, discharge lengths could be extended gradually. Eventually, discharges lasted up to 6 s, reaching an injected energy of 4 MJ, which is twice the limit originally agreedmore » for the limiter configuration employed during the first operational campaign. At power levels of 4 MW central electron densities reached 3 × 10 19 m –3, central electron temperatures reached values of 7 keV and ion temperatures reached just above 2 keV. Important physics studies during this first operational phase include a first assessment of power balance and energy confinement, ECRH power deposition experiments, 2nd harmonic O-mode ECRH using multi-pass absorption, and current drive experiments using electron cyclotron current drive. As in many plasma discharges the electron temperature exceeds the ion temperature significantly, these plasmas are governed by core electron root confinement showing a strong positive electric field in the plasma centre.« less

  20. Graduate Student Project: Employer Operations Management Analysis

    ERIC Educational Resources Information Center

    Fish, Lynn A.

    2008-01-01

    Part-time graduate students at an Association to Advance Collegiate Schools of Business-accredited college complete a unique project by applying operations management concepts to their current employer. More than 92% of 368 graduates indicated that this experiential project was a positive learning experience, and results show a positive impact on…

  1. Efficacy of the alcohol use disorders identification test as a screening tool for hazardous alcohol intake and related disorders in primary care: a validity study.

    PubMed Central

    Piccinelli, M.; Tessari, E.; Bortolomasi, M.; Piasere, O.; Semenzin, M.; Garzotto, N.; Tansella, M.

    1997-01-01

    OBJECTIVE: To determine the properties of the alcohol use disorders identification test in screening primary care attenders for alcohol problems. DESIGN: A validity study among consecutive primary care attenders aged 18-65 years. Every third subject completed the alcohol use disorders identification test (a 10 item self report questionnaire on alcohol intake and related problems) and was interviewed by an investigator with the composite international diagnostic interview alcohol use module (a standardised interview for the independent assessment of alcohol intake and related disorders). SETTING: 10 primary care clinics in Verona, north eastern Italy. PATIENTS: 500 subjects were approached and 482 (96.4%) completed evaluation. RESULTS: When the alcohol use disorders identification test was used to detect subjects with alcohol problems the area under the receiver operating characteristic curve was 0.95. The cut off score of 5 was associated with a sensitivity of 0.84, a specificity of 0.90, and a positive predictive value of 0.60. The screening ability of the total score derived from summing the responses to the five items minimising the probability of misclassification between subjects with and without alcohol problems provided an area under the receiver operating characteristic curve of 0.93. A score of 5 or more on the five items was associated with a sensitivity of 0.79, a specificity of 0.95, and a positive predictive value of 0.73. CONCLUSIONS: The alcohol use disorders identification test performs well in detecting subjects with formal alcohol disorders and those with hazardous alcohol intake. Using five of the 10 items on the questionnaire gives reasonable accuracy, and these are recommended as questions of choice to screen patients for alcohol problems. PMID:9040389

  2. Apparatus and method for grounding compressed fuel fueling operator

    DOEpatents

    Cohen, Joseph Perry; Farese, David John; Xu, Jianguo

    2002-06-11

    A safety system for grounding an operator at a fueling station prior to removing a fuel fill nozzle from a fuel tank upon completion of a fuel filling operation is provided which includes a fuel tank port in communication with the fuel tank for receiving and retaining the nozzle during the fuel filling operation and a grounding device adjacent to the fuel tank port which includes a grounding switch having a contact member that receives physical contact by the operator and where physical contact of the contact member activates the grounding switch. A releasable interlock is included that provides a lock position wherein the nozzle is locked into the port upon insertion of the nozzle into the port and a release position wherein the nozzle is releasable from the port upon completion of the fuel filling operation and after physical contact of the contact member is accomplished.

  3. Model simulation of the Manasquan water-supply system in Monmouth County, New Jersey

    USGS Publications Warehouse

    Chang, Ming; Tasker, Gary D.; Nieswand, Steven

    2001-01-01

    Model simulation of the Manasquan Water Supply System in Monmouth County, New Jersey, was completed using historic hydrologic data to evaluate the effects of operational and withdrawal alternatives on the Manasquan reservoir and pumping system. Changes in the system operations can be simulated with the model using precipitation forecasts. The Manasquan Reservoir system model operates by using daily streamflow values, which were reconstructed from historical U.S. Geological Survey streamflow-gaging station records. The model is able to run in two modes--General Risk analysis Model (GRAM) and Position Analysis Model (POSA). The GRAM simulation procedure uses reconstructed historical streamflow records to provide probability estimates of certain events, such as reservoir storage levels declining below a specific level, when given an assumed set of operating rules and withdrawal rates. POSA can be used to forecast the likelihood of specified outcomes, such as streamflows falling below statutory passing flows, associated with a specific working plan for the water-supply system over a period of months. The user can manipulate the model and generate graphs and tables of streamflows and storage, for example. This model can be used as a management tool to facilitate the development of drought warning and drought emergency rule curves and safe yield values for the water-supply system.

  4. Screening for Binge Eating Disorders Using the Patient Health Questionnaire in a Community Sample

    PubMed Central

    Striegel-Moore, Ruth H.; Perrin, Nancy; DeBar, Lynn; Wilson, G. Terence; Rosselli, Francine; Kraemer, Helena C.

    2009-01-01

    Objective To examine the operating characteristics of the Patient Health Questionnaire eating disorder module (PHQ-ED) for identifying bulimia nervosa/binge eating disorder (BN/BED) or recurrent binge eating (RBE) in a community sample, and to compare true positive (TP) versus false positive (FP) cases on clinical validators. Method 259 screen positive individuals and a random sample of 89 screen negative cases completed a diagnostic interview. Sensitivity, specificity, and Positive Predictive Value (PPV) were calculated. TP and FP cases were compared using t-tests and Chi-Square tests. Results The PHQ-ED had high sensitivity (100%) and specificity (92%) for detecting BN/BED or RBE, but PPV was low (15% or 19%). TP and FP cases did not differ significantly on frequency of subjective bulimic episodes, objective overeating, restraint, on BMI, and on self-rated health. Conclusions The PHQ-ED is recommended for use in large populations only in conjunction with follow-up questions to rule out cases without objective bulimic episodes. PMID:19424976

  5. Evaluation of median nerve T2 signal changes in patients with surgically treated carpal tunnel syndrome.

    PubMed

    Samanci, Yavuz; Karagöz, Yeşim; Yaman, Mehmet; Atçı, İbrahim Burak; Emre, Ufuk; Kılıçkesmez, Nuri Özgür; Çelik, Suat Erol

    2016-11-01

    To determine the accuracy of median nerve T2 evaluation and its relation with Boston Questionnaire (BQ) and nerve conduction studies (NCSs) in pre-operative and post-operative carpal tunnel syndrome (CTS) patients in comparison with healthy volunteers. Twenty-three CTS patients and 24 healthy volunteers underwent NCSs, median nerve T2 evaluation and self-administered BQ. Pre-operative and 1st year post-operative median nerve T2 values and cross-sectional areas (CSAs) were compared both within pre-operative and post-operative CTS groups, and with healthy volunteers. The relationship between MRI findings and BQ and NCSs was analyzed. The ROC curve analysis was used for determining the accuracy. The comparison of pre-operative and post-operative T2 values and CSAs revealed statistically significant improvements in the post-operative patient group (p<0.001 for all parameters). There were positive correlations between T2 values at all levels and BQ values, and positive and negative correlations were also found regarding T2 values and NCS findings in CTS patients. The receiver operating characteristic curve analysis for defined cut-off levels of median nerve T2 values in hands with severe CTS yielded excellent accuracy at all levels. However, this accuracy could not be demonstrated in hands with mild CTS. This study is the first to analyze T2 values in both pre-operative and post-operative CTS patients. The presence of increased T2 values in CTS patients compared to controls and excellent accuracy in hands with severe CTS indicates T2 signal changes related to CTS pathophysiology and possible utilization of T2 signal evaluation in hands with severe CTS. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Validity of Alcohol Use Disorder Identification Test-Korean Revised Version for Screening Alcohol Use Disorder according to Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition Criteria.

    PubMed

    Chang, Jung Wei; Kim, Jong Sung; Jung, Jin Gyu; Kim, Sung Soo; Yoon, Seok Joon; Jang, Hak Sun

    2016-11-01

    The Alcohol Use Disorder Identification Test (AUDIT) has been widely used to identify alcohol use disorder (AUD). This study evaluated the validity of the AUDIT-Korean revised version (AUDIT-KR) for screening AUD according to Diagnostic and Statistical Manual of Mental Disorders, fifth edition (DSM-5) criteria. This research was conducted with 443 subjects who visited the Chungnam National University Hospital for a comprehensive medical examination. All subjects completed the demographic questionnaire and AUDIT-KR without assistance. Subjects were divided into two groups according to DSM-5 criteria: an AUD group, which included patients that fit the criteria for AUD (120 males and 21 females), and a non-AUD group, which included 146 males and 156 females that did not meet AUD criteria. The appropriate cut-off values, sensitivity, specificity, and positive and negative predictive values of the AUDIT-KR were evaluated. The mean±standard deviation AUDIT-KR scores were 10.32±7.48 points in males and 3.23±4.42 points in females. The area under the receiver operating characteristic curve (95% confidence interval, CI) of the AUDIT-KR for identifying AUD was 0.884 (0.840-0.920) in males and 0.962 (0.923-0.985) in females. The optimal cut-off value of the AUDIT-KR was 10 points for males (sensitivity, 81.90%; specificity, 81.33%; positive predictive value, 77.2%; negative predictive value, 85.3%) and 5 points for females (sensitivity, 100.00%; specificity, 88.54%; positive predictive value, 52.6%; negative predictive value, 100.0%). The AUDIT-KR has high reliability and validity for identifying AUD according to DSM-5 criteria.

  7. Complete denture tooth arrangement technology driven by a reconfigurable rule.

    PubMed

    Dai, Ning; Yu, Xiaoling; Fan, Qilei; Yuan, Fulai; Liu, Lele; Sun, Yuchun

    2018-01-01

    The conventional technique for the fabrication of complete dentures is complex, with a long fabrication process and difficult-to-control restoration quality. In recent years, digital complete denture design has become a research focus. Digital complete denture tooth arrangement is a challenging issue that is difficult to efficiently implement under the constraints of complex tooth arrangement rules and the patient's individualized functional aesthetics. The present study proposes a complete denture automatic tooth arrangement method driven by a reconfigurable rule; it uses four typical operators, including a position operator, a scaling operator, a posture operator, and a contact operator, to establish the constraint mapping association between the teeth and the constraint set of the individual patient. By using the process reorganization of different constraint operators, this method can flexibly implement different clinical tooth arrangement rules. When combined with a virtual occlusion algorithm based on progressive iterative Laplacian deformation, the proposed method can achieve automatic and individual tooth arrangement. Finally, the experimental results verify that the proposed method is flexible and efficient.

  8. A Universal Graph Plotting Routine.

    ERIC Educational Resources Information Center

    Bogart, Theodore F., Jr.

    1984-01-01

    Presents a programing subroutine which will create a graphical plot that occupies any number of columns specified by user and will run with versions of BASIC programming language. Illustrations of the subroutine's ability to operate successfully for three possibilities (negative values, positive values, and both positive and negative values) are…

  9. Bilirubin nomogram for prediction of significant hyperbilirubinemia in north Indian neonates.

    PubMed

    Pathak, Umesh; Chawla, Deepak; Kaur, Saranjit; Jain, Suksham

    2013-04-01

    (i) To construct hour-specific serum total bilirubin (STB) nomogram in neonates born at =35 weeks of gestation; (ii)To evaluate efficacy of pre-discharge bilirubin measurement in predicting hyperbilirubinemia needing treatment. Diagnostic test performance in a prospective cohort study. Teaching hospital in Northern India. Healthy neonates with gestation =35 weeks or birth weight =2000 g. Serum total bilirubin was measured in all enrolled neonates at 24 ± 6, 72-96 and 96-144 h of postnatal age and when indicated clinically. Neonates were followed up during hospital stay and after discharge till completion of 7th postnatal day. Key outcome was significant hyperbilirubinemia (SHB) defined as need of phototherapy based on modified American Academy of Pediatrics (AAP) guidelines. In neonates born at 38 or more weeks of gestation middle line and in neonates born at 37 or less completed weeks of gestation, lower line of phototherapy thresholds were used to initiate phototherapy. For construction of nomogram, STB values were clubbed in six-hour epochs (age ± 3 hours) for postnatal age up to 48 h and twelve-hour epochs (age ± 6 hours) for age beyond 48 h. Predictive ability of the nomogram was assessed by calculating sensitivity, specificity, positive predictive value, negative predictive value and likelihood ratio, by plotting receiver-operating characteristics (ROC) curve and calculating c-statistic. 997 neonates (birth weight: 2627 ± 536 g, gestation: 37.8 ± 1.5 weeks) were enrolled, of which 931 completed followup. Among enrolled neonates 344 (34.5%) were low birth weight. Rate of exclusive breastfeeding during hospital stay was more than 80%. Bilirubin nomogram was constructed using 40th, 75th and 95th percentile values of hour-specific bilirubin. Pre-discharge STB of =95th percentile was assigned to be in high-risk zone, between 75th and 94th centile in upper-intermediate risk zone, between 40th and 74th centile in lower-intermediate risk zone and below 40th percentile in low-risk zone. Among 49 neonates with pre-discharge STB in high risk zone. 34 developed SHB (positive predictive value: 69.4%, sensitivity: 17.1%, positive likelihood ratio: 8.26). Among 342 neonates with pre-discharge STB in low risk zone, 32 developed PHB (negative predictive value: 90.6% and specificity: 42.5%, positive likelihood ratio: 0.37). Area under curve for this risk assessment strategy was 0.73. Hour-specific bilirubin nomogram and STB measurement can be used for predicting subsequent need of phototherapy. Further studies are needed to validate performance of risk demarcation zones defined in this hour-specific bilirubin nomogram.

  10. Scopolamine Effects Under a Titrating-Delayed-Nonmatching-to-Position Procedure

    ERIC Educational Resources Information Center

    Porritt, M.; Poling, A.

    2008-01-01

    In a study of working memory, the performance of rats under titrating-delayed-nonmatching- to-position (TDNMTP) procedures was examined. Overall accuracy and the number of trials completed were inversely related to titration value, whereas the highest delay attained was directly related to titration value. When given intraperitoneally,…

  11. Gigapixel surface imaging of radical prostatectomy specimens for comprehensive detection of cancer-positive surgical margins using structured illumination microscopy

    PubMed Central

    Wang, Mei; Tulman, David B.; Sholl, Andrew B.; Kimbrell, Hillary Z.; Mandava, Sree H.; Elfer, Katherine N.; Luethy, Samuel; Maddox, Michael M.; Lai, Weil; Lee, Benjamin R.; Brown, J. Quincy

    2016-01-01

    Achieving cancer-free surgical margins in oncologic surgery is critical to reduce the need for additional adjuvant treatments and minimize tumor recurrence; however, there is a delicate balance between completeness of tumor removal and preservation of adjacent tissues critical for normal post-operative function. We sought to establish the feasibility of video-rate structured illumination microscopy (VR-SIM) of the intact removed tumor surface as a practical and non-destructive alternative to intra-operative frozen section pathology, using prostate cancer as an initial target. We present the first images of the intact human prostate surface obtained with pathologically-relevant contrast and subcellular detail, obtained in 24 radical prostatectomy specimens immediately after excision. We demonstrate that it is feasible to routinely image the full prostate circumference, generating gigapixel panorama images of the surface that are readily interpreted by pathologists. VR-SIM confirmed detection of positive surgical margins in 3 out of 4 prostates with pathology-confirmed adenocarcinoma at the circumferential surgical margin, and furthermore detected extensive residual cancer at the circumferential margin in a case post-operatively classified by histopathology as having negative surgical margins. Our results suggest that the increased surface coverage of VR-SIM could also provide added value for detection and characterization of positive surgical margins over traditional histopathology. PMID:27257084

  12. Experimental realization of generalized qubit measurements based on quantum walks

    NASA Astrophysics Data System (ADS)

    Zhao, Yuan-yuan; Yu, Neng-kun; Kurzyński, Paweł; Xiang, Guo-yong; Li, Chuan-Feng; Guo, Guang-Can

    2015-04-01

    We report an experimental implementation of a single-qubit generalized measurement scenario, the positive-operator valued measure (POVM), based on a quantum walk model. The qubit is encoded in a single-photon polarization. The photon performs a quantum walk on an array of optical elements, where the polarization-dependent translation is performed via birefringent beam displacers and a change of the polarization is implemented with the help of wave plates. We implement: (i) trine POVM, i.e., the POVM elements uniformly distributed on an equatorial plane of the Bloch sphere; (ii) symmetric-informationally-complete (SIC) POVM; and (iii) unambiguous discrimination of two nonorthogonal qubit states.

  13. Can the Hospital Anxiety and Depression (HAD) Scale be used on Chinese elderly in general practice?

    PubMed

    Lam, C L; Pan, P C; Chan, A W; Chan, S Y; Munro, C

    1995-06-01

    A study was carried out in a general practice in Hong Kong to find out if the Hospital Anxiety and Depression (HAD) Scale could be used to detect psychological problems in Chinese elderly. The HAD Scale was translated into Cantonese and administered by an interviewer to 298 Chinese aged 60 or above before their doctor consultations. The acceptance rate of the Scale was 96% and each interview took only 5-10 min to complete. All 298 elderly understood and completed the HAD Scale. Validation of the results of the HAD Scale by the Clinical Interview Schedule (CIS) was done on a random sample of 100 elderly. Relative operating characteristic (ROC) analysis showed that the optimal cut-off points of the HAD Scale was a depression score of 6 and an anxiety score of 3. The sensitivity was 80%, specificity was 90%, OMR (overall misclassification rate) was 12%, positive predictive value was 67% and negative predictive value was 95%. Thirty-six per cent of the elderly had scores above these cut-off points. More females than males had high anxiety scores. Nearly half of those with positive HAD scores were not known to have any psychological illness. The HAD Scale has great potential to be used as a screening instrument for psychological illnesses in Cantonese-speaking Chinese elderly all over the world.

  14. Utility of Adjunctive Digital Subtraction Venography for the Treatment of Saphenous Vein Insufficiency.

    PubMed

    Varcoe, Ramon L; Thomas, Shannon D; Bourke, Victor; Rübesamen, Nicole M K; Lennox, Andrew F

    2017-04-01

    To report the use of adjunctive venography for the treatment of superficial venous reflux. Two hundred consecutive patients (mean age 60.9 years, range 33-86; 128 women) with chronic venous disease underwent saphenous or perforator vein ablation in 268 limbs (305 venous trunks) guided by adjunctive venography and fluoroscopy in addition to ultrasound between October 2010 and May 2016. Intraprocedural venograms were independently evaluated by 2 vascular specialists to identify the presence of venous anomalies and the need for fluoroscopy-guided maneuvers to successfully complete venous ablation. Intraprocedural venography results were compared with preoperative venous duplex scan reports to ascertain if the duplex study could be of value in identifying preoperatively any anatomical variants that may pose a technical challenge to the operator. In this cohort, 542 venograms (2.0/limb) were performed with a mean duration of 4.9±9.1 minutes (range 1-48). Two thirds of patients (132, 66%) had anomalies or abnormalities within the target vein; more than a third (88, 44%) required an endovascular maneuver to successfully complete the ablation and 17% (34) of cases were impossible to complete without adjunctive fluoroscopic guidance. Per-patient comparison of intraprocedural venography with preoperative venous duplex reports identified 21 (11%) patients with abnormalities detected on ultrasound (23 anomalies) compared with 123 (64%) on venography (193 anomalies). This gave ultrasound a 17.1% sensitivity, 100% specificity and positive predictive value, and 40.7% negative predictive value. Venography is a valuable addition to ultrasound to facilitate complete ablation of insufficient saphenous veins in selected patients with complex anatomy.

  15. Completeness of breast cancer operative reports in a community care setting.

    PubMed

    Eng, Jordan Lang; Baliski, Christopher Ronald; McGahan, Colleen; Cai, Eric

    2017-10-01

    The narrative operative report represents the traditional means by which breast cancer surgery has been documented. Previous work has established that omissions occur in narrative operative reports produced in an academic setting. The goal of this study was to determine the completeness of breast cancer narrative operative reports produced in a community care setting and to explore the effect of a surgeon's case volume and years in practice on the completeness of these reports. A standardized retrospective review of operative reports produced over a consecutive 2 year period was performed using a set of procedure-specific elements identified through a review of the relevant literature and work done locally. 772 operative reports were reviewed. 45% of all elements were completely documented. A small positive trend was observed between case volume and completeness while a small negative trend was observed between years in practice and completeness. The dictated narrative report inadequately documents breast cancer surgery irrespective of the recording surgeon's volume or experience. An intervention, such as the implementation of synoptic reporting, should be considered in an effort to maximize the utility of the breast cancer operative report. Copyright © 2017. Published by Elsevier Ltd.

  16. Extended space expectation values of position related operators for hydrogen-like quantum system evolutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalay, Berfin; Demiralp, Metin

    2014-10-06

    The expectation value definitions over an extended space from the considered Hilbert space of the system under consideration is given in another paper of the second author in this symposium. There, in that paper, the conceptuality rather than specification is emphasized on. This work uses that conceptuality to investigate the time evolutions of the position related operators' expectation values not in its standard meaning but rather in a new version of the definition over not the original Hilbert space but in the space obtained by extensions via introducing the images of the given initial wave packet under the positive integermore » powers of the system Hamiltonian. These images may not be residing in the same space of the initial wave packet when certain singularities appear in the structure of the system Hamiltonian. This may break down the existence of the integrals in the definitions of the expectation values. The cure is the use of basis functions in the abovementioned extended space and the sandwiching of the target operator whose expectation value is under questioning by an appropriately chosen operator guaranteeing the existence of the relevant integrals. Work specifically focuses on the hydrogen-like quantum systems whose Hamiltonians contain a polar singularity at the origin.« less

  17. Evaluation of a completely robotized neurosurgical operating microscope.

    PubMed

    Kantelhardt, Sven R; Finke, Markus; Schweikard, Achim; Giese, Alf

    2013-01-01

    Operating microscopes are essential for most neurosurgical procedures. Modern robot-assisted controls offer new possibilities, combining the advantages of conventional and automated systems. We evaluated the prototype of a completely robotized operating microscope with an integrated optical coherence tomography module. A standard operating microscope was fitted with motors and control instruments, with the manual control mode and balance preserved. In the robot mode, the microscope was steered by a remote control that could be fixed to a surgical instrument. External encoders and accelerometers tracked microscope movements. The microscope was additionally fitted with an optical coherence tomography-scanning module. The robotized microscope was tested on model systems. It could be freely positioned, without forcing the surgeon to take the hands from the instruments or avert the eyes from the oculars. Positioning error was about 1 mm, and vibration faded in 1 second. Tracking of microscope movements, combined with an autofocus function, allowed determination of the focus position within the 3-dimensional space. This constituted a second loop of navigation independent from conventional infrared reflector-based techniques. In the robot mode, automated optical coherence tomography scanning of large surface areas was feasible. The prototype of a robotized optical coherence tomography-integrated operating microscope combines the advantages of a conventional manually controlled operating microscope with a remote-controlled positioning aid and a self-navigating microscope system that performs automated positioning tasks such as surface scans. This demonstrates that, in the future, operating microscopes may be used to acquire intraoperative spatial data, volume changes, and structural data of brain or brain tumor tissue.

  18. Quantum incompatibility of channels with general outcome operator algebras

    NASA Astrophysics Data System (ADS)

    Kuramochi, Yui

    2018-04-01

    A pair of quantum channels is said to be incompatible if they cannot be realized as marginals of a single channel. This paper addresses the general structure of the incompatibility of completely positive channels with a fixed quantum input space and with general outcome operator algebras. We define a compatibility relation for such channels by identifying the composite outcome space as the maximal (projective) C*-tensor product of outcome algebras. We show theorems that characterize this compatibility relation in terms of the concatenation and conjugation of channels, generalizing the recent result for channels with quantum outcome spaces. These results are applied to the positive operator valued measures (POVMs) by identifying each of them with the corresponding quantum-classical (QC) channel. We also give a characterization of the maximality of a POVM with respect to the post-processing preorder in terms of the conjugate channel of the QC channel. We consider another definition of compatibility of normal channels by identifying the composite outcome space with the normal tensor product of the outcome von Neumann algebras. We prove that for a given normal channel, the class of normally compatible channels is upper bounded by a special class of channels called tensor conjugate channels. We show the inequivalence of the C*- and normal compatibility relations for QC channels, which originates from the possibility and impossibility of copying operations for commutative von Neumann algebras in C*- and normal compatibility relations, respectively.

  19. A comparison of cognitive skills between completes and dropouts in a college physics course

    NASA Astrophysics Data System (ADS)

    Hudson, H. T.

    Separate tests of mathematics skills, proportions and translations between words, and mathematical expression given the first week of class were correlated with performance for students who completed a college physics course (completes) and students who dropped the course (drops). None of the measures used discriminated between completes and drops as groups. However, the correlations between score on the test of math skills and on both of the measures involving mathematical reasoning (proportions, and translations) were dramatically different for the two groups. For the completes, these correlations were slightly negative, but not significant. For the drops, the correlation was positive and signficant at the p < 0.01 level. This suggests the possibility that the students who complete the course tend to have independent cognitive skills for the mechanical mathematical operations and for questions requiring some degree of reasoning, while, in contrast, the same skills for students at high risk for dropping overlap significantly. The study also found that when students are given the results of mathematics skills tests in a diagnostic mode, with feedback on specific areas of weakness and time to remediate with self study, the correlation between mathematics and physics is lower than previously reported values.Received: 2 April 1985

  20. College Women's Value Orientations toward Family, Career, and Graduate School.

    ERIC Educational Resources Information Center

    Battle, Ann; Wigfield, Allan

    2003-01-01

    Scales assessing intention to attend graduate school and family/career values were completed by 216 college women. Multiple regression analyses demonstrated that components of task value (intrinsic-attainment, utility, cost) predicted graduate study intentions. Strong career orientation was positively related to the valuing of graduate education.…

  1. Irreversibility of Asymptotic Entanglement Manipulation Under Quantum Operations Completely Preserving Positivity of Partial Transpose.

    PubMed

    Wang, Xin; Duan, Runyao

    2017-11-03

    We demonstrate the irreversibility of asymptotic entanglement manipulation under quantum operations that completely preserve the positivity of partial transpose (PPT), resolving a major open problem in quantum information theory. Our key tool is a new efficiently computable additive lower bound for the asymptotic relative entropy of entanglement with respect to PPT states, which can be used to evaluate the entanglement cost under local operations and classical communication (LOCC). We find that for any rank-two mixed state supporting on the 3⊗3 antisymmetric subspace, the amount of distillable entanglement by PPT operations is strictly smaller than one entanglement bit (ebit) while its entanglement cost under PPT operations is exactly one ebit. As a by-product, we find that for this class of states, both the Rains's bound and its regularization are strictly less than the asymptotic relative entropy of entanglement. So, in general, there is no unique entanglement measure for the manipulation of entanglement by PPT operations. We further show a computable sufficient condition for the irreversibility of entanglement distillation by LOCC (or PPT) operations.

  2. Hemoglobin A1c can be helpful in predicting progression to diabetes after Whipple procedure.

    PubMed

    Hamilton, Lisa; Jeyarajah, D Rohan

    2007-01-01

    Normoglycemic patients undergoing pancreaticoduodenectomy (Whipple procedure) often inquire whether they will be diabetic postoperatively. There is limited information on this issue. We therefore looked at a more subtle measurement of long-term glycemic control, hemoglobin A1c (HgbA1c), as a prognostic tool in predicting progression to diabetes post Whipple. A retrospective review over a 6-year period of all patients undergoing Whipple procedures at a single institution was conducted. In all, 27 patients had no prior history of diabetes, complete follow-up, and measured preoperative HgbA1c values. Postoperative diabetes was defined as the need for oral hypoglycemic agents or insulin. These charts were analyzed for progression to diabetes after Whipple. Of the 27 patients, 10 were considered to have postoperative diabetes. The average preoperative HgbA1c value for these patients was 6.3+/-0.66. This was statistically different from the 17 patients without postoperative diabetes (average HgbA1c 5.2+/-0.39, p<0.001). The positive predictive value, negative predictive value, sensitivity, and specificity were 82%, 94%, 90%, and 88%, respectively. This study demonstrates that progression to diabetes is very unlikely after Whipple operation if the preoperative HgbA1c value is in the normal range. The apparent utility of HgbA1c in predicting postoperative diabetes in this small study suggests that this laboratory test may be very helpful in counseling patients for Whipple operation.

  3. Diagnostic Performance of Ultrasonography for Pediatric Appendicitis: A Night and Day Difference?

    PubMed

    Mangona, Kate Louise M; Guillerman, R Paul; Mangona, Victor S; Carpenter, Jennifer; Zhang, Wei; Lopez, Monica; Orth, Robert C

    2017-12-01

    For imaging pediatric appendicitis, ultrasonography (US) is preferred because of its lack of ionizing radiation, but is limited by operator dependence. This study investigates the US diagnostic performance during night shifts covered by radiology trainees compared to day shifts covered by attending radiologists. Appy-Scores (1 = completely visualized normal appendix; 2 = partially visualized normal appendix; 3 = nonvisualized appendix with no inflammatory changes in the expected region of the appendix; 4 = equivocal; 5a = nonperforated appendicitis; 5b = perforated appendicitis) from 2935 US examinations (2161:774, day-to-night) from July 2013 to 2014 were correlated with the intraoperative diagnoses and the clinical follow-up. The diagnostic performance of trainees and attendings was compared with Fisher exact test. Interobserver agreement was measured by Cohen kappa coefficient. Appendicitis prevalence was 25.3% (day) and 22.5% (night). Sensitivity, specificity, accuracy, negative predictive value, and positive predictive vale were 94.0%, 93.7%, 93.8%, 97.9%, and 83.4% during the day and 92.0%, 91.2%, 91.3%, 97.5%, and 75.2% at night. Specificity (P = .048) and positive predictive value (P = .011) differed, with more false positives at night (7%) than during the day (4.7%). Trainee and attending agreement was high (k = 0.995), with Appy-Scores of 1, 4, and 5a most frequently discordant. US has a high diagnostic performance and interobserver agreement for pediatric appendicitis when interpreted by radiology trainees during night shifts or attending radiologists during day shifts. However, lower specificity and positive predictive value at night warrants a thorough trainee education to avoid false-positive examinations. Published by Elsevier Inc.

  4. Identifying messaging completion in a parallel computer by checking for change in message received and transmitted count at each node

    DOEpatents

    Archer, Charles J [Rochester, MN; Hardwick, Camesha R [Fayetteville, NC; McCarthy, Patrick J [Rochester, MN; Wallenfelt, Brian P [Eden Prairie, MN

    2009-06-23

    Methods, parallel computers, and products are provided for identifying messaging completion on a parallel computer. The parallel computer includes a plurality of compute nodes, the compute nodes coupled for data communications by at least two independent data communications networks including a binary tree data communications network optimal for collective operations that organizes the nodes as a tree and a torus data communications network optimal for point to point operations that organizes the nodes as a torus. Embodiments include reading all counters at each node of the torus data communications network; calculating at each node a current node value in dependence upon the values read from the counters at each node; and determining for all nodes whether the current node value for each node is the same as a previously calculated node value for each node. If the current node is the same as the previously calculated node value for all nodes of the torus data communications network, embodiments include determining that messaging is complete and if the current node is not the same as the previously calculated node value for all nodes of the torus data communications network, embodiments include determining that messaging is currently incomplete.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalay, Berfin; Demiralp, Metin

    This proceedings paper aims to show the efficiency of an expectation value identity for a given algebraic function operator which is assumed to be depending pn only position operator. We show that this expectation value formula becomes enabled to determine the eigenstates of the quantum system Hamiltonian as long as it is autonomous and an appropriate basis set in position operator is used. This approach produces a denumerable infinite recursion which may be considered as revisited but at the same time generalized form of the recursions over the natural number powers of the position operator. The content of this shortmore » paper is devoted not only to the formulation of the new method but also to show that this novel approach is capable of catching the eigenvalues and eigenfunctions for Hydrogen-like systems, beyond that, it can give a hand to us to reveal the wavefunction structure. So it has also somehow a confirmative nature.« less

  6. Cold Test Operation of the German VEK Vitrification Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fleisch, J.; Schwaab, E.; Weishaupt, M.

    2008-07-01

    In 2007 the German High-Level Liquid Waste (HLLW) Vitrification plant VEK (Verglasungseinrichtung Karlsruhe) has passed a three months integral cold test operation as final step before entering the hot phase. The overall performance of the vitrification process equipment with a liquid-fed ceramic glass melter as main component proved to be completely in line with the requirements of the regulatory body. The retention efficiency of main radioactive-bearing elements across melter and wet off-gas treatment system exceeded the design values distinctly. The strategy to produce a specified waste glass could be successfully demonstrated. The results of the cold test operation allow enteringmore » the next step of hot commissioning, i.e. processing of approximately 2 m{sup 3} of diluted HLLW. In summary: An important step of the VEK vitrification plant towards hot operation has been the performance of the cold test operation from April to July 2007. This first integral operation was carried out under boundary conditions and rules established for radioactive operation. Operation and process control were carried out following the procedure as documented in the licensed operational manuals. The function of the process technology and the safe operation could be demonstrated. No severe problems were encountered. Based on the positive results of the cold test, application of the license for hot operation has been initiated and is expected in the near future. (authors)« less

  7. [Comparative study of proximal femoral shortening after the third generation of Gamma nail versus proximal femoral nail anti-rotation in treatment of intertrochanteric fracture].

    PubMed

    Hou, Yu; Yao, Qi; Zhang, Gen'ai; Ding, Lixiang

    2018-03-01

    To explore the difference of the proximal femoral shortening (PFS) between the third generation of Gamma nail (TGN) and the proximal femoral nail anti-rotation (PFNA) in treating intertrochanteric fracture of femur. The clinical data of 158 patients with intertrochanteric fracture of femur who were treated with TGN internal fixation or PFNA internal fixation between January 2014 and December 2015 were retrospectively analysed. The patients were divided into TGN group (69 cases) and PFNA group (89 cases) according to surgical operation. There was no significant difference in gender, age, bone mineral density, causes of injury, AO/Association for the Study of Internal Fixation (AO/ASIF) classification, accompanied disease, and the time from injury to operation between 2 groups ( P >0.05). The result of fracture reduction was divided into 3 types: positive medial cortex support, neutral position cortex support, and negative medial cortex support according to the method of Chang et al . At 18 months postoperatively, bilateral hip anteroposterior X-ray films were taken to measure horizontal PFS values (marked as X), vertical PFS values (marked as Y), and calculate the total PFS values (marked as Z). The PFS values were divided into 4 grades according to the criteria (≤1.0 mm, 1.0-4.9 mm, 5.0-9.9 mm, and ≥10.0 mm), and the constituent ratio was calculated and compared between 2 groups. The X, Y, and Z values and the collodiaphyseal angles of 2 groups at 18 months postoperatively were compared. The X, Y, and Z values of 2 groups of patients with failed fixation and normal healing within 18 months after operation were recorded and compared. The X, Y, and Z values of 2 groups of the patients with different cortex support types were also compared. There were 34 cases of positive medial cortex support, 30 cases of neutral position cortex support, and 5 cases of negative medial cortex support in TGN group, and there were 45, 33, and 11 cases in PFNA group respectively, showing no significant difference between 2 groups ( Z =-1.06, P =0.29). All patients were followed up 18 months after operation. At 18 months after operation, the constituent ratios of PFS values (X, Y, Z) had significant differences between 2 groups ( P <0.05). The patients of shortening of 1.0-4.9 mm and 5.0-9.9 mm were obviously more in TGN group than in PFNA group; the patients of shortening of ≥10.0 mm were obviously more in PFNA group than in TGN group. There were significant differences in X, Y, and Z values between 2 groups ( P <0.05), but no significant difference of the collodiaphysial angle was found between 2 groups ( t =0.47, P =0.64). Six cases of internal fixation failed in TGN group and PFNA group respectively within 3 months after operation, and there was no significant difference of X, Y, and Z values between failed fixation and normal healing patients within 2 groups ( P >0.05). When the reposition effect was the positive medial cortex support, the X, Y, and Z values were significantly lower in TGN group than in PFNA group ( P <0.05); but no significant difference was found between 2 groups when the reposition effect was the neutral position cortex support or negative medial cortex support ( P >0.05). At 18 months after operation, the X, Y, and Z values of the negative medial cortex support patients were significantly higher than those of the positive medial cortex support or the neutral position cortex support patients within 2 groups ( P <0.05). PFS is a common complication of the intertrochanteric fracture of the femur after internal fixation. During operation, the selection of internal fixation should be based on the results of intraoperative reduction. TGN should be applied to reduce PFS if positive medial cortex support happened.

  8. Evaluation of the influence of blood glucose level on oral candidal colonization in complete denture wearers with Type-II Diabetes Mellitus: An in vivo Study.

    PubMed

    Ganapathy, Dhanraj Muthuveera; Joseph, Sajeesh; Ariga, Padma; Selvaraj, Anand

    2013-01-01

    Candidal colonization in complete denture wearers is a commonly encountered condition that worsens in the presence of untreated Diabetes Mellitus. The aim of this study was to evaluate the correlation between oral candidiasis in denture-bearing mucosa and elevated blood glucose levels in complete denture wearers and to evaluate the effect of oral hypoglycemic drug therapy in controlling oral candidal colonization in denture-bearing mucosa of complete denture wearers with Type II Diabetes Mellitus. This prospective observational study involved the participation of 15 complete denture wearers with Type II Diabetes Mellitus. The sample collection was made prior and after oral hypoglycaemic drug intervention, by swabbing the rugal surfaces of palatal mucosa, cultured and the density of the candidal colony formed was analyzed and interpreted as colony forming units (CFU) per mL. The candidal samples CFU and corresponding pre- and post-prandial blood glucose levels were estimated, analyzed and compared using Karl Pearson correlation analysis and paired t-test (α = 0.05). The Karl Pearson correlation analysis showed that there was a positive correlation between the blood glucose levels (PPS and FBS) and the candidal colonization (CFU) (P < 0.05). The mean values of all the variables were analyzed using the paired t-test. There was significant reduction in the mean values of blood glucose levels (P < 0.001) and the mean values of the CFU (P < 0.001) following oral hypoglycemic drug therapy. Positive correlation was observed between oral candidiasis in complete denture-bearing mucosa and elevated blood glucose levels and oral hypoglycemic drug therapy has a positive effect in controlling oral candidal colonization in complete denture wearers with Type II Diabetes Mellitus.

  9. Quantum Tasks with Non-maximally Quantum Channels via Positive Operator-Valued Measurement

    NASA Astrophysics Data System (ADS)

    Peng, Jia-Yin; Luo, Ming-Xing; Mo, Zhi-Wen

    2013-01-01

    By using a proper positive operator-valued measure (POVM), we present two new schemes for probabilistic transmission with non-maximally four-particle cluster states. In the first scheme, we demonstrate that two non-maximally four-particle cluster states can be used to realize probabilistically sharing an unknown three-particle GHZ-type state within either distant agent's place. In the second protocol, we demonstrate that a non-maximally four-particle cluster state can be used to teleport an arbitrary unknown multi-particle state in a probabilistic manner with appropriate unitary operations and POVM. Moreover the total success probability of these two schemes are also worked out.

  10. A characterization of positive linear maps and criteria of entanglement for quantum states

    NASA Astrophysics Data System (ADS)

    Hou, Jinchuan

    2010-09-01

    Let H and K be (finite- or infinite-dimensional) complex Hilbert spaces. A characterization of positive completely bounded normal linear maps from {\\mathcal B}(H) into {\\mathcal B}(K) is given, which particularly gives a characterization of positive elementary operators including all positive linear maps between matrix algebras. This characterization is then applied to give a representation of quantum channels (operations) between infinite-dimensional systems. A necessary and sufficient criterion of separability is given which shows that a state ρ on HotimesK is separable if and only if (ΦotimesI)ρ >= 0 for all positive finite-rank elementary operators Φ. Examples of NCP and indecomposable positive linear maps are given and are used to recognize some entangled states that cannot be recognized by the PPT criterion and the realignment criterion.

  11. Welfare effects of reduced milk production associated with Johne's disease on Johne's-positive versus Johne's-negative dairy operations.

    PubMed

    Losinger, Willard C

    2006-08-01

    An examination of the economic impacts of reduced milk production associated with Johne's disease on Johne's-positive and Johne's-negative dairy operations indicated that, if Johne's disease had not existed in US dairy cows in 1996, then the economic surplus of Johne's-negative operations would have been $600 million+/-$530 million lower, while the economic surplus of Johne's-positive operations would have been higher by $28 million+/-$79 million, which was not significantly different from zero. The data available for projecting changes in surplus were not sufficiently precise to allow an exact statement on whether Johne's-positive operations would have been better or worse off economically, in terms of the value received for producing more milk if they had not been affected by Johne's disease. The changes in producer surplus, based upon eliminating specific epidemiological risk factors for Johne's disease, were disaggregated between Johne's-positive dairy operations exposed to the risk factor and all other US dairy operations. Eliminating the risk factor of having any cows not born on the operation would have had a significant positive effect on the economic surplus of Johne's-positive operations that had any cows not born on the operation.

  12. Position and Disposition: The Contextual Development of Human Values

    ERIC Educational Resources Information Center

    Longest, Kyle C.; Hitlin, Steven; Vaisey, Stephen

    2013-01-01

    Research on the importance of values often focuses primarily on one domain of social predictors (e.g., economic) or limits its scope to a single dimension of values. We conduct a simultaneous analysis of a wide range of theoretically important social influences and a more complete range of individuals' value orientations, focusing both on value…

  13. Renal cell carcinoma with venous extension: prediction of inferior vena cava wall invasion by MRI.

    PubMed

    Adams, Lisa C; Ralla, Bernhard; Bender, Yi-Na Y; Bressem, Keno; Hamm, Bernd; Busch, Jonas; Fuller, Florian; Makowski, Marcus R

    2018-05-03

    Renal cell carcinoma (RCC) are accompanied by inferior vena cava (IVC) thrombus in up to 10% of the cases, with surgical resection remaining the only curative option. In case of IVC wall invasion, the operative procedure is more challenging and may even require IVC resection. This study aims to determine the diagnostic performance of contrast-enhanced magnetic resonance imaging (MRI) for the assessment of wall invasion by IVC thrombus in patients with RCC, validated with intraoperative findings. Data were collected on 81 patients with RCC and IVC thrombus, who received a radical nephrectomy and vena cava thrombectomy between February 2008 and November 2017. Forty eight patients met the inclusion criteria. Sensitivity and specificity as well as the positive and negative predictive values were calculated for preoperative MRI, based on the assessments of the two readers for visual wall invasion. Furthermore, a logistic regression model was used to determine if there was an association between intraoperative wall adherence and IVC diameter. Complete occlusion of the IVC lumen or vessel breach could reliably assess IVC wall invasion with a sensitivity of 92.3% (95%-CI: 0.75-0.99) and a specificity of 86.4% (95%-CI: 0.65-0.97) (Fisher-test: p-value< 0.001). The positive predictive value (PPV) was 88.9% (95%-CI: 0.71-0.98) and the negative predictive value reached 90.5% (95%-CI: 0.70-0.99). There was an excellent interobserver agreement for determining IVC wall invasion with a kappa coefficient of 0.90 (95%CI: 0.79-1.00). The present study indicates that standard preoperative MR imaging can be used to reliably assess IVC wall invasion, evaluating morphologic features such as the complete occlusion of the IVC lumen or vessel breach. Increases in IVC diameter are associated with a higher probability of IVC wall invasion.

  14. Predictive value of the korean academy of family medicine in-training examination for certifying examination.

    PubMed

    Cho, Jung-Jin; Kim, Ji-Yong

    2011-09-01

    In-training examination (ITE) is a cognitive examination similar to the written test, but it is different from the Clinical Practice Examination of the Korean Academy of Family Medicine (KAFM) Certification Examination (CE). The objective of this is to estimate the positive predictive value of the KAFM-ITE for identifying residents at risk for poor performance on the three types of KAFM-CE. 372 residents who completed the KAFM-CE in 2011 were included. We compared the mean KAFM-CE scores with ITE experience. We evaluated the correlation and the positive predictive value (PPV) of ITE for the multiple choice question (MCQ) scores of 1st written test & 2nd slide examination, the total clinical practice examination scores, and the total sum of 2nd test. 275 out of 372 residents completed ITE. Those who completed ITE had significantly higher MCQ scores of 1st written test than those who did not. The correlation of ITE scores with 1st written MCQ (0.627) was found to be the highest among the other kinds of CE. The PPV of the ITE score for 1st written MCQ scores was 0.672. The PPV of the ITE score ranged from 0.376 to 0.502. The score of the KAFM ITE has acceptable positive predictive value that could be used as a part of comprehensive evaluation system for residents in cognitive field.

  15. Recommendations for UAS Crew Ratings. Pilot Ratings and Authorization Requirements for UAS

    NASA Technical Reports Server (NTRS)

    2005-01-01

    This position paper is intended to recommend the minimum certificate and rating requirements for a pilot to operate an Unmanned Aircraft System (UAS) in the National Airspace System. The paper will recommend the minimum requirements based on the Knowledge, Skills, and Abilities (KSA) required of a UAS pilot and show how those compare to the KSAs required by regulation for manned-aircraft pilots. The paper will provide substantiation based on studies conducted using analyses, simulation and flight experience. The paper is not yet complete; only initial working material is included. The material provided describes the body of work completed thus far and the plan for remaining tasks to complete the recommendation. The HSI Pilot KSA document provides an analysis of the knowledge, skills, and abilities required for UAS operation in the NAS. It is the source document used for the position paper.

  16. The Effect of the Position of an Item within a Test on the Item Difficulty Value.

    ERIC Educational Resources Information Center

    Rubin, Lois S.; Mott, David E. W.

    An investigation of the effect on the difficulty value of an item due to position placement within a test was made. Using a 60-item operational test comprised of 5 subtests, 60 items were placed as experimental items on a number of spiralled test forms in three different positions (first, middle, last) within the subtest composed of like items.…

  17. The Keck keyword layer

    NASA Technical Reports Server (NTRS)

    Conrad, A. R.; Lupton, W. F.

    1992-01-01

    Each Keck instrument presents a consistent software view to the user interface programmer. The view consists of a small library of functions, which are identical for all instruments, and a large set of keywords, that vary from instrument to instrument. All knowledge of the underlying task structure is hidden from the application programmer by the keyword layer. Image capture software uses the same function library to collect data for the image header. Because the image capture software and the instrument control software are built on top of the same keyword layer, a given observation can be 'replayed' by extracting keyword-value pairs from the image header and passing them back to the control system. The keyword layer features non-blocking as well as blocking I/O. A non-blocking keyword write operation (such as setting a filter position) specifies a callback to be invoked when the operation is complete. A non-blocking keyword read operation specifies a callback to be invoked whenever the keyword changes state. The keyword-callback style meshes well with the widget-callback style commonly used in X window programs. The first keyword library was built for the two Keck optical instruments. More recently, keyword libraries have been developed for the infrared instruments and for telescope control. Although the underlying mechanisms used for inter-process communication by each of these systems vary widely (Lick MUSIC, Sun RPC, and direct socket I/O, respectively), a basic user interface has been written that can be used with any of these systems. Since the keyword libraries are bound to user interface programs dynamically at run time, only a single set of user interface executables is needed. For example, the same program, 'xshow', can be used to display continuously the telescope's position, the time left in an instrument's exposure, or both values simultaneously. Less generic tools that operate on specific keywords, for example an X display that controls optical instrument exposures, have also been written using the keyword layer.

  18. Sentinel lymph node biopsy in cutaneous head and neck melanoma.

    PubMed

    Evrard, D; Routier, E; Mateus, C; Tomasic, G; Lombroso, J; Kolb, F; Robert, C; Moya-Plana, A

    2018-05-01

    Sentinel lymph node biopsy (SLNB) is now a standard of care for cutaneous melanoma, but it is still controversial for cutaneous head and neck melanoma (CHNM). This study aims to confirm the feasibility, accuracy and low morbidity of SLNB in CHNM and evaluate its prognostic value. A monocentric and retrospective study on patients with CHNM treated in our tertiary care center (Gustave Roussy) between January 2008 and December 2012 was performed. The feasibility, morbidity and prognostic value of this technique were analysed. One hundred and twenty-four consecutive patients were included. SLNB was realized in 97.6% of the cases. No significant post-operative morbidity was observed. Nineteen percents of patients had a positive SN while only 14.3% of complete lymph node dissections (CLND) had additional nodal metastasis. The risk of recurrence after positive SN was significantly higher (69.2 vs 30.8%, p = 0.043). The false omission rate was low with 7.1%. Overall survival and disease-free survival were better in the negative SN group (82 vs 49%, p < 0.001 and 69.3 vs 41.8%, p = 0.0131). The risk of recurrence was significantly higher in the positive SN group (p = 0.043) and when primary tumour was ulcerated (p = 0.031). Only the mitotic rate of the primary tumour was associated with SN positivity (p = 0.049). As in other sites, SLNB status is a strong prognostic factor with comparable false omission rate and no superior morbidity.

  19. The Stroke Assessment of Fall Risk (SAFR): predictive validity in inpatient stroke rehabilitation.

    PubMed

    Breisinger, Terry P; Skidmore, Elizabeth R; Niyonkuru, Christian; Terhorst, Lauren; Campbell, Grace B

    2014-12-01

    To evaluate relative accuracy of a newly developed Stroke Assessment of Fall Risk (SAFR) for classifying fallers and non-fallers, compared with a health system fall risk screening tool, the Fall Harm Risk Screen. Prospective quality improvement study conducted at an inpatient stroke rehabilitation unit at a large urban university hospital. Patients admitted for inpatient stroke rehabilitation (N = 419) with imaging or clinical evidence of ischemic or hemorrhagic stroke, between 1 August 2009 and 31 July 2010. Not applicable. Sensitivity, specificity, and area under the curve for Receiver Operating Characteristic Curves of both scales' classifications, based on fall risk score completed upon admission to inpatient stroke rehabilitation. A total of 68 (16%) participants fell at least once. The SAFR was significantly more accurate than the Fall Harm Risk Screen (p < 0.001), with area under the curve of 0.73, positive predictive value of 0.29, and negative predictive value of 0.94. For the Fall Harm Risk Screen, area under the curve was 0.56, positive predictive value was 0.19, and negative predictive value was 0.86. Sensitivity and specificity of the SAFR (0.78 and 0.63, respectively) was higher than the Fall Harm Risk Screen (0.57 and 0.48, respectively). An evidence-derived, population-specific fall risk assessment may more accurately predict fallers than a general fall risk screen for stroke rehabilitation patients. While the SAFR improves upon the accuracy of a general assessment tool, additional refinement may be warranted. © The Author(s) 2014.

  20. Failure of conservative treatment with Gastrografin® for adhesive small bowel obstruction after colorectal surgery.

    PubMed

    Miquel, Jordi; Biondo, Sebastiano; Kreisler, Esther; Uribe, Catalina; Trenti, Loris

    2017-07-01

    The aim of this study was to identify risk factors related with failure of conservative management of adhesive small bowel obstruction (ASBO) in patients with previous colorectal surgery. Patients admitted with the diagnosis of ASBO after previous colorectal resection, were included. All patients underwent administration of Gastrografin®. Abdominal radiography was done after 24 h, to confirm the presence of contrast in colon (incomplete obstruction) or not (complete obstruction). Several factors were investigated to study their relationship with the failure of conservative management. Failure of conservative management was considered when emergency operation was needed to solve ASBO. Incomplete obstruction was observed in 174 episodes (93.0%) while in 13 (7.0%) was complete. One hundred seventy-one ASBO episodes (91.4%) responded successfully to nonoperative treatment and 16 (8.6%) required emergency surgery. Five patients needed bowel resection. Results on the diagnostic test with Gastrografin® showed a sensitivity of 75%, specificity of 99%, positive predictive value 92%, and negative predictive value 98%. Age over 75 years was the only predictive factor for failure of conservative management. The median waiting time from the radiologic confirmation of complete obstruction to surgery was higher in patients requiring bowel resection when compared to those who did not need resection. The use of Gastrografin® in ASBO after colorectal resection is a safe and useful tool for the indication of conservative management. Age over 75 years is a predictive factor for need of surgery. Surgery should be performed no later than the following 24 h of confirmed complete obstruction.

  1. Cytokines as a predictor of clinical response following hip arthroscopy: minimum 2-year follow-up.

    PubMed

    Shapiro, Lauren M; Safran, Marc R; Maloney, William J; Goodman, Stuart B; Huddleston, James I; Bellino, Michael J; Scuderi, Gaetano J; Abrams, Geoffrey D

    2016-08-01

    Hip arthroscopy in patients with osteoarthritis has been shown to have suboptimal outcomes. Elevated cytokine concentrations in hip synovial fluid have previously been shown to be associated with cartilage pathology. The purpose of this study was to determine whether a relationship exists between hip synovial fluid cytokine concentration and clinical outcomes at a minimum of 2 years following hip arthroscopy. Seventeen patients without radiographic evidence of osteoarthritis had synovial fluid aspirated at time of portal establishment during hip arthroscopy. Analytes included fibronectin-aggrecan complex as well as a multiplex cytokine array. Patients completed the modified Harris Hip Score, Western Ontario and McMaster Universities Arthritis Index and the International Hip Outcomes Tool pre-operatively and at a minimum of 2 years following surgery. Pre and post-operative scores were compared with a paired t-test, and the association between cytokine values and clinical outcome scores was performed with Pearson's correlation coefficient with an alpha value of 0.05 set as significant. Sixteen of seventeen patients completed 2-year follow-up questionnaires (94%). There was a significant increase in pre-operative to post-operative score for each clinical outcome measure. No statistically significant correlation was seen between any of the intra-operative cytokine values and either the 2-year follow-up scores or the change from pre-operative to final follow-up outcome values. No statistically significant associations were seen between hip synovial fluid cytokine concentrations and 2-year follow-up clinical outcome assessment scores for those undergoing hip arthroscopy.

  2. Radiance, polarization, and ellipticity of the radiation in the earth's atmosphere

    NASA Technical Reports Server (NTRS)

    Hitzfelder, S. J.; Plass, G. N.; Kattawar, G. W.

    1976-01-01

    The complete radiation field including polarization is calculated for a model of the real atmosphere by the matrix operator method. The radiance, direction and amount of polarization, and ellipticity are obtained at the top and bottom of the atmosphere for three values of the surface albedo (0; 0.15 0.90) and five solar zenith angles. Scattering and absorption by molecules (including ozone) and by aerosols are taken into account together with the variation of the number density of these substances with height. All results are calculated for both a normal aerosol number and a distribution which is one-third of the normal amount at all heights. The calculated values show general qualitative agreement with the available experimental measurements. The position of the neutral points of the polarization in the principal plane is a sensitive indicator of the characteristics of the aerosol particles in the atmosphere, since it depends on the sign and value of the single scattered polarization for scattering angles around 20 deg and 160 deg for transmitted and reflected photons respectively.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spickermann, Thomas

    There are opportunities for advancement within the team. Operators advance by: (1) Becoming fully qualified - following the LANSCE Accelerator Operator Training Manual, Operator trainees go through 5 levels of qualification, from Radiation Security System to Experimental Area Operator. Must obtain Knowledge and Performance checkouts by an OSS or AOSS, and an End-of-Card checkout by the team leader or RSS engineer (level I). Program was inspired by US NAVY qualification program for nuclear reactor operators. Time to complete: 2-2.5 years. (2) Fully qualified operators are eligible to apply for vacant (OSS)/AOSS positions; and (3) Alternatively, experienced operators can sign upmore » for the voluntary Senior Operator Qualification Program. They must demonstrate in-depth knowledge of all areas of the accelerator complex. Time to complete is 2-3 years (Minimum 4 years from fully qualified). Eligible for promotion to level between qualified operator and AOSS.« less

  4. Prediction of Neonatal Hyperbilirubinemia Using 1st Day Serum Bilirubin Levels.

    PubMed

    Spoorthi, S M; Dandinavar, Siddappa F; Ratageri, Vinod H; Wari, Prakash K

    2018-02-15

    The study was conducted on Full term neonates with birth weight > 2.5 kg born in KIMS, Hubballi with an objective to determine the first day Total Serum Bilirubin (TSB) value so as to predict subsequent development of significant hyperbilirubinemia in term neonates. All enrolled neonates were sampled for TSB and blood group on Day 1 at 20 ± 4 h and then followed up clinically by Kramer's rule and when the clinical jaundice by Kramer's rule was >10 mg/dl, TSB levels were repeated. A total of 180 newborns were enrolled for the study and 165 babies completed the study. Out of these, 17(10.3%) babies had significant hyperbilirubinemia by day 5 of life. Using Receiver Operating Characteristic (ROC) Curve, a cut off TSB value of 6.15 mg/dl was determined with sensitivity of 82.4%, specificity of 81.8%, positive predictive value of 32.8%, negative predictive value 97.6%. In term neonates, the first day total bilirubin level at 20 ± 4 h of life <6.15 predicts the low risk of subsequent significant hyperbilirubinemia with high probability.

  5. Electromyographic evaluation of masseter and anterior temporalis muscles in rest position of edentulous patients with temporomandibular disorders, before and after using complete dentures with sliding plates.

    PubMed

    Zuccolotto, Maria Cristina Candelas; Vitti, Mathias; Nóbilo, Krunislave Antônio; Regalo, Simone Cecílio Hallak; Siéssere, Selma; Bataglion, César

    2007-06-01

    This study was performed with the purpose of investigating electromyographic (EMG) activity of the anterior temporalis and masseter muscles in edentulous individuals with temporomandibular disorder (TMD), before and after using sliding plates on complete dentures in the mandibular rest position. Edentulous patients may present TMD, which is characterised by pain in temporomandibular joints, masticatory and neck muscles, uncoordinated and limited mandible movements, joint sounds and an altered occlusal relationship. It is imperative to offer treatment in order to re-establish stomatognathic system structures before submitting the individual to any definitive restorative treatment. The patients were edentulous for at least 10 years. EMG recordings were made before the insertion of the dentures (0 months) and also after using the sliding plates at the fourth month, 9th month and 12th month, using computerised electromyography K6-I/ EMG Light Channel Surface. EMG evaluations of the muscles were performed under the following clinical conditions: rest position with dentures (R1), rest position without dentures (R2), rest position with dentures post-activity (chewing) (R3), rest position without dentures post-activity (chewing) (R4). All patients obtained remission of muscular fatigue and reduced pain in stomatognathic system structures. Temporalis muscle showed significant increase in EMG activity compared with initial values (p < 0.01). Masseter muscles showed significantly lower mean values (p < 0.01) compared with initial values. The sliding plates allowed the process of neuromuscular deprogramming, contributing to muscular balance of the masticatory system, and are therefore indicated to be used before the fabrication of definitive complete dentures in patients with TMD.

  6. 30 CFR 70.220 - Status change reports.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... to all miners expected to wear a CPDM. The training shall be completed prior to a miner wearing a... cutting machine. On the cutting machine operator or on the cutting machine within 36 inches inby the normal working position; (2) Conventional section blasting off the solid. On the loading machine operator...

  7. Learning curve for laparoscopic Heller myotomy and Dor fundoplication for achalasia

    PubMed Central

    Omura, Nobuo; Tsuboi, Kazuto; Hoshino, Masato; Yamamoto, Seryung; Akimoto, Shunsuke; Masuda, Takahiro; Kashiwagi, Hideyuki; Yanaga, Katsuhiko

    2017-01-01

    Purpose Although laparoscopic Heller myotomy and Dor fundoplication (LHD) is widely performed to address achalasia, little is known about the learning curve for this technique. We assessed the learning curve for performing LHD. Methods Of the 514 cases with LHD performed between August 1994 and March 2016, the surgical outcomes of 463 cases were evaluated after excluding 50 cases with reduced port surgery and one case with the simultaneous performance of laparoscopic distal partial gastrectomy. A receiver operating characteristic (ROC) curve analysis was used to identify the cut-off value for the number of surgical experiences necessary to become proficient with LHD, which was defined as the completion of the learning curve. Results We defined the completion of the learning curve when the following 3 conditions were satisfied. 1) The operation time was less than 165 minutes. 2) There was no blood loss. 3) There was no intraoperative complication. In order to establish the appropriate number of surgical experiences required to complete the learning curve, the cut-off value was evaluated by using a ROC curve (AUC 0.717, p < 0.001). Finally, we identified the cut-off value as 16 surgical cases (sensitivity 0.706, specificity 0.646). Conclusion Learning curve seems to complete after performing 16 cases. PMID:28686640

  8. Learning curve for laparoscopic Heller myotomy and Dor fundoplication for achalasia.

    PubMed

    Yano, Fumiaki; Omura, Nobuo; Tsuboi, Kazuto; Hoshino, Masato; Yamamoto, Seryung; Akimoto, Shunsuke; Masuda, Takahiro; Kashiwagi, Hideyuki; Yanaga, Katsuhiko

    2017-01-01

    Although laparoscopic Heller myotomy and Dor fundoplication (LHD) is widely performed to address achalasia, little is known about the learning curve for this technique. We assessed the learning curve for performing LHD. Of the 514 cases with LHD performed between August 1994 and March 2016, the surgical outcomes of 463 cases were evaluated after excluding 50 cases with reduced port surgery and one case with the simultaneous performance of laparoscopic distal partial gastrectomy. A receiver operating characteristic (ROC) curve analysis was used to identify the cut-off value for the number of surgical experiences necessary to become proficient with LHD, which was defined as the completion of the learning curve. We defined the completion of the learning curve when the following 3 conditions were satisfied. 1) The operation time was less than 165 minutes. 2) There was no blood loss. 3) There was no intraoperative complication. In order to establish the appropriate number of surgical experiences required to complete the learning curve, the cut-off value was evaluated by using a ROC curve (AUC 0.717, p < 0.001). Finally, we identified the cut-off value as 16 surgical cases (sensitivity 0.706, specificity 0.646). Learning curve seems to complete after performing 16 cases.

  9. Executing a gather operation on a parallel computer

    DOEpatents

    Archer, Charles J [Rochester, MN; Ratterman, Joseph D [Rochester, MN

    2012-03-20

    Methods, apparatus, and computer program products are disclosed for executing a gather operation on a parallel computer according to embodiments of the present invention. Embodiments include configuring, by the logical root, a result buffer or the logical root, the result buffer having positions, each position corresponding to a ranked node in the operational group and for storing contribution data gathered from that ranked node. Embodiments also include repeatedly for each position in the result buffer: determining, by each compute node of an operational group, whether the current position in the result buffer corresponds with the rank of the compute node, if the current position in the result buffer corresponds with the rank of the compute node, contributing, by that compute node, the compute node's contribution data, if the current position in the result buffer does not correspond with the rank of the compute node, contributing, by that compute node, a value of zero for the contribution data, and storing, by the logical root in the current position in the result buffer, results of a bitwise OR operation of all the contribution data by all compute nodes of the operational group for the current position, the results received through the global combining network.

  10. Predictive Value of the Korean Academy of Family Medicine In-Training Examination for Certifying Examination

    PubMed Central

    Kim, Ji-Yong

    2011-01-01

    Background In-training examination (ITE) is a cognitive examination similar to the written test, but it is different from the Clinical Practice Examination of the Korean Academy of Family Medicine (KAFM) Certification Examination (CE). The objective of this is to estimate the positive predictive value of the KAFM-ITE for identifying residents at risk for poor performance on the three types of KAFM-CE. Methods 372 residents who completed the KAFM-CE in 2011 were included. We compared the mean KAFM-CE scores with ITE experience. We evaluated the correlation and the positive predictive value (PPV) of ITE for the multiple choice question (MCQ) scores of 1st written test & 2nd slide examination, the total clinical practice examination scores, and the total sum of 2nd test. Results 275 out of 372 residents completed ITE. Those who completed ITE had significantly higher MCQ scores of 1st written test than those who did not. The correlation of ITE scores with 1st written MCQ (0.627) was found to be the highest among the other kinds of CE. The PPV of the ITE score for 1st written MCQ scores was 0.672. The PPV of the ITE score ranged from 0.376 to 0.502. Conclusion The score of the KAFM ITE has acceptable positive predictive value that could be used as a part of comprehensive evaluation system for residents in cognitive field. PMID:22745873

  11. The Relationship between Earned Value Management Metrics and Customer Satisfaction

    ERIC Educational Resources Information Center

    Plumer, David R.

    2010-01-01

    Information Technology (IT) products have a high rate of failure. Only 25% of IT projects were completed within budget and schedule, and 15% of completed projects were not operational. Researchers have not investigated the success of project management systems from the perspective of customer satisfaction. In this quantitative study, levels of…

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Müller-Hermes, Alexander, E-mail: muellerh@ma.tum.de; Wolf, Michael M., E-mail: m.wolf@tum.de; Reeb, David, E-mail: reeb.qit@gmail.com

    We investigate linear maps between matrix algebras that remain positive under tensor powers, i.e., under tensoring with n copies of themselves. Completely positive and completely co-positive maps are trivial examples of this kind. We show that for every n ∈ ℕ, there exist non-trivial maps with this property and that for two-dimensional Hilbert spaces there is no non-trivial map for which this holds for all n. For higher dimensions, we reduce the existence question of such non-trivial “tensor-stable positive maps” to a one-parameter family of maps and show that an affirmative answer would imply the existence of non-positive partial transposemore » bound entanglement. As an application, we show that any tensor-stable positive map that is not completely positive yields an upper bound on the quantum channel capacity, which for the transposition map gives the well-known cb-norm bound. We, furthermore, show that the latter is an upper bound even for the local operations and classical communications-assisted quantum capacity, and that moreover it is a strong converse rate for this task.« less

  13. Flow Meter

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Hedland Flow Meters manufactures a complete line of flow meters used in industrial operations to monitor the flow of oil, water or other liquids, air and other compressed gases, including caustics or corrosive liquids/gases. The company produces more than 1,000 types of flow meters featuring rugged construction, simplicity of installation and the ability to operate in any position.

  14. Work motivation among healthcare professionals.

    PubMed

    Kjellström, Sofia; Avby, Gunilla; Areskoug-Josefsson, Kristina; Andersson Gäre, Boel; Andersson Bäck, Monica

    2017-06-19

    Purpose The purpose of this paper is to explore work motivation among professionals at well-functioning primary healthcare centers subject to a national healthcare reform which include financial incentives. Design/methodology/approach Five primary healthcare centers in Sweden were purposively selected for being well-operated and representing public/private and small/large units. In total, 43 interviews were completed with different medical professions and qualitative deductive content analysis was conducted. Findings Work motivation exists for professionals when their individual goals are aligned with the organizational goals and the design of the reform. The centers' positive management was due to a unique combination of factors, such as clear direction of goals, a culture of non-hierarchical collaboration, and systematic quality improvement work. The financial incentives need to be translated in terms of quality patient care to provide clear direction for the professionals. Social processes where professionals work together as cohesive groups, and provided space for quality improvement work is pivotal in addressing how alignment is created. Practical implications Leaders need to consistently translate and integrate reforms with the professionals' drives and values. This is done by encouraging participation through teamwork, time for structured reflection, and quality improvement work. Social implications The design of the reforms and leadership are essential preconditions for work motivation. Originality/value The study offers a more complete picture of how reforms are managed at primary healthcare centers, as different medical professionals are included. The value also consists of showing how a range of aspects combine for primary healthcare professionals to successfully manage external reforms.

  15. Risk score for first-screening of prevalent undiagnosed chronic kidney disease in Peru: the CRONICAS-CKD risk score.

    PubMed

    Carrillo-Larco, Rodrigo M; Miranda, J Jaime; Gilman, Robert H; Medina-Lezama, Josefina; Chirinos-Pacheco, Julio A; Muñoz-Retamozo, Paola V; Smeeth, Liam; Checkley, William; Bernabe-Ortiz, Antonio

    2017-11-29

    Chronic Kidney Disease (CKD) represents a great burden for the patient and the health system, particularly if diagnosed at late stages. Consequently, tools to identify patients at high risk of having CKD are needed, particularly in limited-resources settings where laboratory facilities are scarce. This study aimed to develop a risk score for prevalent undiagnosed CKD using data from four settings in Peru: a complete risk score including all associated risk factors and another excluding laboratory-based variables. Cross-sectional study. We used two population-based studies: one for developing and internal validation (CRONICAS), and another (PREVENCION) for external validation. Risk factors included clinical- and laboratory-based variables, among others: sex, age, hypertension and obesity; and lipid profile, anemia and glucose metabolism. The outcome was undiagnosed CKD: eGFR < 60 ml/min/1.73m 2 . We tested the performance of the risk scores using the area under the receiver operating characteristic (ROC) curve, sensitivity, specificity, positive/negative predictive values and positive/negative likelihood ratios. Participants in both studies averaged 57.7 years old, and over 50% were females. Age, hypertension and anemia were strongly associated with undiagnosed CKD. In the external validation, at a cut-off point of 2, the complete and laboratory-free risk scores performed similarly well with a ROC area of 76.2% and 76.0%, respectively (P = 0.784). The best assessment parameter of these risk scores was their negative predictive value: 99.1% and 99.0% for the complete and laboratory-free, respectively. The developed risk scores showed a moderate performance as a screening test. People with a score of ≥ 2 points should undergo further testing to rule out CKD. Using the laboratory-free risk score is a practical approach in developing countries where laboratories are not readily available and undiagnosed CKD has significant morbidity and mortality.

  16. Neural network based automatic limit prediction and avoidance system and method

    NASA Technical Reports Server (NTRS)

    Calise, Anthony J. (Inventor); Prasad, Jonnalagadda V. R. (Inventor); Horn, Joseph F. (Inventor)

    2001-01-01

    A method for performance envelope boundary cueing for a vehicle control system comprises the steps of formulating a prediction system for a neural network and training the neural network to predict values of limited parameters as a function of current control positions and current vehicle operating conditions. The method further comprises the steps of applying the neural network to the control system of the vehicle, where the vehicle has capability for measuring current control positions and current vehicle operating conditions. The neural network generates a map of current control positions and vehicle operating conditions versus the limited parameters in a pre-determined vehicle operating condition. The method estimates critical control deflections from the current control positions required to drive the vehicle to a performance envelope boundary. Finally, the method comprises the steps of communicating the critical control deflection to the vehicle control system; and driving the vehicle control system to provide a tactile cue to an operator of the vehicle as the control positions approach the critical control deflections.

  17. Protocol for fermionic positive-operator-valued measures

    NASA Astrophysics Data System (ADS)

    Arvidsson-Shukur, D. R. M.; Lepage, H. V.; Owen, E. T.; Ferrus, T.; Barnes, C. H. W.

    2017-11-01

    In this paper we present a protocol for the implementation of a positive-operator-valued measure (POVM) on massive fermionic qubits. We present methods for implementing nondispersive qubit transport, spin rotations, and spin polarizing beam-splitter operations. Our scheme attains linear opticslike control of the spatial extent of the qubits by considering ground-state electrons trapped in the minima of surface acoustic waves in semiconductor heterostructures. Furthermore, we numerically simulate a high-fidelity POVM that carries out Procrustean entanglement distillation in the framework of our scheme, using experimentally realistic potentials. Our protocol can be applied not only to pure ensembles with particle pairs of known identical entanglement, but also to realistic ensembles of particle pairs with a distribution of entanglement entropies. This paper provides an experimentally realizable design for future quantum technologies.

  18. A general framework for complete positivity

    NASA Astrophysics Data System (ADS)

    Dominy, Jason M.; Shabani, Alireza; Lidar, Daniel A.

    2016-01-01

    Complete positivity of quantum dynamics is often viewed as a litmus test for physicality; yet, it is well known that correlated initial states need not give rise to completely positive evolutions. This observation spurred numerous investigations over the past two decades attempting to identify necessary and sufficient conditions for complete positivity. Here, we describe a complete and consistent mathematical framework for the discussion and analysis of complete positivity for correlated initial states of open quantum systems. This formalism is built upon a few simple axioms and is sufficiently general to contain all prior methodologies going back to Pechakas (Phys Rev Lett 73:1060-1062, 1994). The key observation is that initial system-bath states with the same reduced state on the system must evolve under all admissible unitary operators to system-bath states with the same reduced state on the system, in order to ensure that the induced dynamical maps on the system are well defined. Once this consistency condition is imposed, related concepts such as the assignment map and the dynamical maps are uniquely defined. In general, the dynamical maps may not be applied to arbitrary system states, but only to those in an appropriately defined physical domain. We show that the constrained nature of the problem gives rise to not one but three inequivalent types of complete positivity. Using this framework, we elucidate the limitations of recent attempts to provide conditions for complete positivity using quantum discord and the quantum data processing inequality. In particular, we correct the claim made by two of us (Shabani and Lidar in Phys Rev Lett 102:100402-100404, 2009) that vanishing discord is necessary for complete positivity, and explain that it is valid only for a particular class of initial states. The problem remains open, and may require fresh perspectives and new mathematical tools. The formalism presented herein may be one step in that direction.

  19. Early pregnancy angiogenic markers and spontaneous abortion: an Odense Child Cohort study.

    PubMed

    Andersen, Louise B; Dechend, Ralf; Karumanchi, S Ananth; Nielsen, Jan; Joergensen, Jan S; Jensen, Tina K; Christesen, Henrik T

    2016-11-01

    Spontaneous abortion is the most commonly observed adverse pregnancy outcome. The angiogenic factors soluble Fms-like kinase 1 and placental growth factor are critical for normal pregnancy and may be associated to spontaneous abortion. We investigated the association between maternal serum concentrations of soluble Fms-like kinase 1 and placental growth factor, and subsequent spontaneous abortion. In the prospective observational Odense Child Cohort, 1676 pregnant women donated serum in early pregnancy, gestational week <22 (median 83 days of gestation, interquartile range 71-103). Concentrations of soluble Fms-like kinase 1 and placental growth factor were determined with novel automated assays. Spontaneous abortion was defined as complete or incomplete spontaneous abortion, missed abortion, or blighted ovum <22+0 gestational weeks, and the prevalence was 3.52% (59 cases). The time-dependent effect of maternal serum concentrations of soluble Fms-like kinase 1 and placental growth factor on subsequent late first-trimester or second-trimester spontaneous abortion (n = 59) was evaluated using a Cox proportional hazards regression model, adjusting for body mass index, parity, season of blood sampling, and age. Furthermore, receiver operating characteristics were employed to identify predictive values and optimal cut-off values. In the adjusted Cox regression analysis, increasing continuous concentrations of both soluble Fms-like kinase 1 and placental growth factor were significantly associated with a decreased hazard ratio for spontaneous abortion: soluble Fms-like kinase 1, 0.996 (95% confidence interval, 0.995-0.997), and placental growth factor, 0.89 (95% confidence interval, 0.86-0.93). When analyzed by receiver operating characteristic cut-offs, women with soluble Fms-like kinase 1 <742 pg/mL had an odds ratio for spontaneous abortion of 12.1 (95% confidence interval, 6.64-22.2), positive predictive value of 11.70%, negative predictive value of 98.90%, positive likelihood ratio of 3.64 (3.07-4.32), and negative likelihood ratio of 0.30 (0.19-0.48). For placental growth factor <19.7 pg/mL, odds ratio was 13.2 (7.09-24.4), positive predictive value was 11.80%, negative predictive value was 99.0%, positive likelihood ratio was 3.68 (3.12-4.34), and negative likelihood ratio was 0.28 (0.17-0.45). In the sensitivity analysis of 54 spontaneous abortions matched 1:4 to controls on gestational age at blood sampling, the highest area under the curve was seen for soluble Fms-like kinase 1 in prediction of first-trimester spontaneous abortion, 0.898 (0.834-0.962), and at the optimum cut-off of 725 pg/mL, negative predictive value was 51.4%, positive predictive value was 94.6%, positive likelihood ratio was 4.04 (2.57-6.35), and negative likelihood ratio was 0.22 (0.09-0.54). A strong, novel prospective association was identified between lower concentrations of soluble Fms-like kinase 1 and placental growth factor measured in early pregnancy and spontaneous abortion. A soluble Fms-like kinase 1 cut-off <742 pg/mL in maternal serum was optimal to stratify women at high vs low risk of spontaneous abortion. The cause and effect of angiogenic factor alterations in spontaneous abortions remain to be elucidated. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Preoperative Serum Thyrotropin to Thyroglobulin Ratio Is Effective for Thyroid Nodule Evaluation in Euthyroid Patients.

    PubMed

    Wang, Lina; Li, Hao; Yang, Zhongyuan; Guo, Zhuming; Zhang, Quan

    2015-07-01

    This study was designed to assess the efficiency of the serum thyrotropin to thyroglobulin ratio for thyroid nodule evaluation in euthyroid patients. Cross-sectional study. Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China. Retrospective analysis was performed for 400 previously untreated cases presenting with thyroid nodules. Thyroid function was tested with commercially available radioimmunoassays. The receiver operating characteristic curves were constructed to determine cutoff values. The efficacy of the thyrotropin:thyroglobulin ratio and thyroid-stimulating hormone for thyroid nodule evaluation was evaluated in terms of sensitivity, specificity, positive predictive value, positive likelihood ratio, negative likelihood ratio, and odds ratio. In receiver operating characteristic curve analysis, the area under the curve was 0.746 for the thyrotropin:thyroglobulin ratio and 0.659 for thyroid-stimulating hormone. With a cutoff point value of 24.97 IU/g for the thyrotropin:thyroglobulin ratio, the sensitivity, specificity, positive predictive value, positive likelihood ratio, and negative likelihood ratio were 78.9%, 60.8%, 75.5%, 2.01, and 0.35, respectively. The odds ratio for the thyrotropin:thyroglobulin ratio indicating malignancy was 5.80. With a cutoff point value of 1.525 µIU/mL for thyroid-stimulating hormone, the sensitivity, specificity, positive predictive value, positive likelihood ratio, and negative likelihood ratio were 74.0%, 53.2%, 70.8%, 1.58, and 0.49, respectively. The odds ratio indicating malignancy for thyroid-stimulating hormone was 3.23. Increasing preoperative serum thyrotropin:thyroglobulin ratio is a risk factor for thyroid carcinoma, and the correlation of the thyrotropin:thyroglobulin ratio to malignancy is higher than that for serum thyroid-stimulating hormone. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  1. Probabilistic Teleportation of an Arbitrary Two-Qubit State via Positive Operator-Valued Measurement with Multi Parties

    NASA Astrophysics Data System (ADS)

    Shi, Lei; Wei, Jia-Hua; Li, Yun-Xia; Ma, Li-Hua; Xue, Yang; Luo, Jun-Wen

    2017-04-01

    We propose a novel scheme to probabilistically transmit an arbitrary unknown two-qubit quantum state via Positive Operator-Valued Measurement with the help of two partially entangled states. In this scheme, the teleportation with two senders and two receives can be realized when the information of non-maximally entangled states is only available for the senders. Furthermore, the concrete implementation processes of this proposal are presented, meanwhile the classical communication cost and the successful probability of our scheme are calculated. Supported by the National Natural Science Foundation of China under Grant Nos. 60974037, 61134008, 11074307, and 61273202

  2. Minimal sufficient positive-operator valued measure on a separable Hilbert space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuramochi, Yui, E-mail: kuramochi.yui.22c@st.kyoto-u.ac.jp

    We introduce a concept of a minimal sufficient positive-operator valued measure (POVM), which is the least redundant POVM among the POVMs that have the equivalent information about the measured quantum system. Assuming the system Hilbert space to be separable, we show that for a given POVM, a sufficient statistic called a Lehmann-Scheffé-Bahadur statistic induces a minimal sufficient POVM. We also show that every POVM has an equivalent minimal sufficient POVM and that such a minimal sufficient POVM is unique up to relabeling neglecting null sets. We apply these results to discrete POVMs and information conservation conditions proposed by the author.

  3. Implementation of generalized quantum measurements for unambiguous discrimination of multiple non-orthogonal coherent states.

    PubMed

    Becerra, F E; Fan, J; Migdall, A

    2013-01-01

    Generalized quantum measurements implemented to allow for measurement outcomes termed inconclusive can perform perfect discrimination of non-orthogonal states, a task which is impossible using only measurements with definitive outcomes. Here we demonstrate such generalized quantum measurements for unambiguous discrimination of four non-orthogonal coherent states and obtain their quantum mechanical description, the positive-operator valued measure. For practical realizations of this positive-operator valued measure, where noise and realistic imperfections prevent perfect unambiguous discrimination, we show that our experimental implementation outperforms any ideal standard-quantum-limited measurement performing the same non-ideal unambiguous state discrimination task for coherent states with low mean photon numbers.

  4. Acute effects of caffeine on several operant behaviors in rhesus monkeys.

    PubMed

    Buffalo, E A; Gillam, M P; Allen, R R; Paule, M G

    1993-11-01

    The acute effects of 1,3-trimethylxanthine (caffeine) were assessed using an operant test battery (OTB) of complex food-reinforced tasks that are thought to depend upon relatively specific brain functions, such as motivation to work for food (progressive ratio, PR), learning (incremental repeated acquisition, IRA), color and position discrimination (conditioned position responding, CPR), time estimation (temporal response differentiation, TRD), and short-term memory and attention (delayed matching-to-sample, DMTS). Endpoints included response rates (RR), accuracies (ACC), and percent task completed (PTC). Caffeine sulfate (0.175-20.0 mg/kg, IV), given 15 min pretesting, produced significant dose-dependent decreases in TRD percent task completed and accuracy at doses > or = 5.6 mg/kg. Caffeine produced no systematic effects on either DMTS or PR responding, but low doses tended to enhance performance in both IRA and CPR tasks. Thus, in monkeys, performance of an operant task designed to model time estimation is more sensitive to the disruptive effects of caffeine than is performance of the other tasks in the OTB.

  5. Risk factors influencing the early outcome results after laparoscopic repair of perforated duodenal ulcer and their predictive value.

    PubMed

    Lunevicius, Raimundas; Morkevicius, Matas

    2005-09-01

    Clear patient selection criteria and indications for laparoscopic repair of perforated duodenal ulcers are necessary. The aims of our study are to report the early outcome results after operation and to define the predictive values of risk factors influencing conversion rate and genesis of suture leakage. Sixty nonrandomly selected patients operated on laparoscopically in a tertiary care academic center between October 1996 and May 2004 for perforated duodenal ulcers were retrospectively analyzed. The primary outcome measures included the duration of symptoms, shock, underlying medical illness, ulcer size, age, Boey score, and the collective predictive value of these variables for conversion and suture leakage rates. Laparoscopic repair was completed in 46 patients (76.7%). Fourteen patients (23.3%) underwent conversion to open repair. Eight patients (13.3%) had postoperative complications. Suture leakage was confirmed in four patients (6.7%). Hospital stay was 7.8+/-5.3 days. There was no mortality. Patients with an ulcer perforation size of >8 mm had a significantly increased risk for conversion to open repair (p<0.05): positive predictive value (PPV) 75%, sensitivity 27%, specificity 98%, and negative predictive value (NPV) 85%. The significance of ulcer perforation size was confirmed by a stepwise logistic regression test (p=0.0201). All patients who developed suture leakage had acute symptoms for >9 h preoperatively (p<0.001): PPV 31%, specificity 84%, sensitivity 100%, and NPV 100%. Conversions happened with surgeons whose previous experience involved 1.8+/-2.3 cases compared to 3.9+/-2.9 cases in successful laparoscopic repair (p=0.039, t test). Ulcer perforation size of >8 mm is a significant risk factor influencing the conversion rate. An increase in the suture leakage rate is predicted by delayed presentation of >9 h.

  6. Project W-314 acceptance test report HNF-4643 for HNF-4642 241-AN-A valve pit manifold valves and position indication for project W-314

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    HAMMERS, J.S.

    1999-09-22

    The purpose of the test was to verify that the AN Tank Farm Manifold Valves can be manually manipulated to the required operating position and that the electrical and visual indications accurately reflect that position. Physical locking devices were also verified to function. The Acceptance Test Procedure HNF-4642, 241-AN-A Valve Pit Manifold Valves and Position Indication was conducted between 23 June and 10 August 1999 at the 200E AN Tank Farm. The test has no open test exceptions. The test was conducted prior to final engineering ''as built'' activities being completed, this had an impact on the procedure and testmore » results, ECN 653752 was written to correct the mismatch between the procedure and actual field conditions. P&ID H-14-100941 was changed via ECN-W-314-4C-120. All components, identified in the procedure, were not found to be labeled and identified as written in the procedure, temporary tags were used for operational identification. A retest of valve ANA-WT-V 318 was required because it was removed from its installed position and modified after testing was completed.« less

  7. Probing finite coarse-grained virtual Feynman histories with sequential weak values

    NASA Astrophysics Data System (ADS)

    Georgiev, Danko; Cohen, Eliahu

    2018-05-01

    Feynman's sum-over-histories formulation of quantum mechanics has been considered a useful calculational tool in which virtual Feynman histories entering into a coherent quantum superposition cannot be individually measured. Here we show that sequential weak values, inferred by consecutive weak measurements of projectors, allow direct experimental probing of individual virtual Feynman histories, thereby revealing the exact nature of quantum interference of coherently superposed histories. Because the total sum of sequential weak values of multitime projection operators for a complete set of orthogonal quantum histories is unity, complete sets of weak values could be interpreted in agreement with the standard quantum mechanical picture. We also elucidate the relationship between sequential weak values of quantum histories with different coarse graining in time and establish the incompatibility of weak values for nonorthogonal quantum histories in history Hilbert space. Bridging theory and experiment, the presented results may enhance our understanding of both weak values and quantum histories.

  8. Quantum thermodynamics of general quantum processes.

    PubMed

    Binder, Felix; Vinjanampathy, Sai; Modi, Kavan; Goold, John

    2015-03-01

    Accurately describing work extraction from a quantum system is a central objective for the extension of thermodynamics to individual quantum systems. The concepts of work and heat are surprisingly subtle when generalizations are made to arbitrary quantum states. We formulate an operational thermodynamics suitable for application to an open quantum system undergoing quantum evolution under a general quantum process by which we mean a completely positive and trace-preserving map. We derive an operational first law of thermodynamics for such processes and show consistency with the second law. We show that heat, from the first law, is positive when the input state of the map majorizes the output state. Moreover, the change in entropy is also positive for the same majorization condition. This makes a strong connection between the two operational laws of thermodynamics.

  9. Localized chromophobe renal cell carcinoma: preoperative imaging judgment and laparoscopic simple enucleation for treatment.

    PubMed

    Ren, Wenbiao; Xue, Bichen; Qu, Jiandong; Liu, Longfei; Li, Chao; Zu, Xiongbing

    2018-04-30

    To evaluate the preoperative imaging manifestation and therapeutic effect of laparoscopic simple enucleation (SE) for localized chromophobe renal cell carcinoma (chRCC). Clinical data of 36 patients who underwent laparoscopic SE of localized chRCC at our institute were retrospectively analyzed. All patients underwent preoperative renal protocol CT (unenhanced, arterial, venous, and delayed images). CT scan characteristics were evaluated. After intraoperative occlusion of the renal artery, the tumor was free bluntly along the pseudocapsule and enucleated totally. The patients were followed up regularly after the operation. Mean tumor diameter was 3.9±1.0 cm, 80% of tumors were homogeneous and all the tumors had complete pseudocapsule. The attenuation values were slightly lower than normal renal cortex and degree of enhancement of the tumors were significantly lower than normal renal cortex. Mean operation time was 104.3±18.2 min. Mean warm ischemia time (WIT) was 21.3±3.5 min. Mean blood loss was 78.6±25.4 mL. No positive surgical margin was identified. Mean postoperative hospital stay was 5.3±1.5 d. Hematuria occurred in 3 patients and all disappeared within 3 days. After a mean follow-up of 32.1±20.6 months, no patient had local recurrence or metastatic progression. Localized chRCCs have a great propensity for homogeneity and complete pseudocapsule. The attenuation values were slightly lower than normal renal cortex and small degree of enhancement. Laparoscopic SE is a safe and effective treatment for localized chRCC. The oncological results were satisfactory. Copyright® by the International Brazilian Journal of Urology.

  10. Convergence of moment expansions for expectation values with embedded random matrix ensembles and quantum chaos

    NASA Astrophysics Data System (ADS)

    Kota, V. K. B.

    2003-07-01

    Smoothed forms for expectation values < K> E of positive definite operators K follow from the K-density moments either directly or in many other ways each giving a series expansion (involving polynomials in E). In large spectroscopic spaces one has to partition the many particle spaces into subspaces. Partitioning leads to new expansions for expectation values. It is shown that all the expansions converge to compact forms depending on the nature of the operator K and the operation of embedded random matrix ensembles and quantum chaos in many particle spaces. Explicit results are given for occupancies < ni> E, spin-cutoff factors < JZ2> E and strength sums < O†O> E, where O is a one-body transition operator.

  11. Comparison of Three-Dimensional Planning-Assisted and Conventional Acetabular Cup Positioning in Total Hip Arthroplasty: A Randomized Controlled Trial.

    PubMed

    Sariali, Elhadi; Boukhelifa, Nadia; Catonne, Yves; Pascal Moussellard, Hugues

    2016-01-20

    Malpositioning of the acetabular cup during total hip arthroplasty increases the risk of dislocation, edge-loading, squeaking, early wear, and loosening. We hypothesized that the use of three-dimensional (3-D) visualization tools to identify the planned cup position relative to the acetabular edge intraoperatively would increase the accuracy of cup orientation. The purpose of this study was to compare 3-D planning-assisted implantation and freehand insertion of the acetabular cup. This was a prospective randomized controlled study of two groups of twenty-eight patients each. In the first group, cup positioning was guided by 3-D views of the cup within the acetabulum obtained during 3-D preoperative planning. In the control group, the cup was placed freehand. All of the patients were operated on by the same surgeon, through a minimally invasive direct anterior approach with the patient in the supine position. Cup anteversion and abduction angles were measured on 3-D computed tomography (CT) reconstructions. The main evaluation criterion was the percentage of outliers according to the Lewinnek safe zone. Operative time did not differ between the two groups. The cup anteversion was more accurate in the 3-D planning group (mean difference from the planned angle [and standard deviation], -2.7° ± 5.4°) compared with the freehand-placement group (6.6° ± 9.5°). According to the Lewinnek safe zone, overall, the percentage of outliers was lower in the 3-D planning group (21%; six patients) than in the control group (46%; thirteen patients). According to the Callanan safe zone, the percentage of outliers was also lower in the 3-D planning group (25% versus 64%). Although cup abduction was also restored with greater accuracy in the 3-D planning group, on the basis of the Lewinnek safe zone, the percentage of abduction outliers was comparable between groups, with fewer high-abduction values, but more low-abduction values, in the 3-D planning group. Preoperative 3-D planning increased the accuracy of anteversion restoration and reduced the percentage of outliers without increasing the operative time. In this study, the same advantage could not be demonstrated for abduction. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  12. Development and validation of a parent-report measure for detection of cognitive delay in infancy.

    PubMed

    Schafer, Graham; Genesoni, Lucia; Boden, Greg; Doll, Helen; Jones, Rosamond A K; Gray, Ron; Adams, Eleri; Jefferson, Ros

    2014-12-01

    To develop a brief, parent-completed instrument (ERIC - Early Report by Infant Caregivers) for detection of cognitive delay in 10- to 24-month-olds born preterm, or of low birthweight, or with perinatal complications, and to establish ERIC's diagnostic properties. Scores for ERIC were collected from the parents of 317 children meeting ≥inclusion criterion (birthweight <1500 g, gestational age <34 completed weeks, 5 min Apgar score <7, or presence of hypoxic-ischaemic encephalopathy) and no exclusion criteria. Children were assessed using a criterion score of below 80 on the Bayley Scales of Infant and Toddler Development-III cognitive scale. Items were retained according to their individual associations with delay. Sensitivity, specificity, and positive and negative predictive values were estimated and a truncated ERIC was developed for use in children <14 months old. ERIC correctly detected developmental delay in 17 out of 18 children in the sample, with 94.4% sensitivity, 76.9% specificity, 19.8% positive predictive value, 99.6% negative predictive value, 4.09 likelihood ratio positive, and 0.07 likelihood ratio negative. ERIC has potential value as a quickly administered diagnostic instrument for the absence of early cognitive delay in 10- to 24-month-old preterm infants and as a screen for cognitive delay. © 2014 Mac Keith Press.

  13. Bidirectional associations between valued activities and adolescent positive adjustment in a longitudinal study: positive mood as a mediator.

    PubMed

    DesRoches, Andrea; Willoughby, Teena

    2014-02-01

    Although activity involvement has been linked to positive youth development, the value that adolescents place on these activities (i.e., how much they enjoy the activities, find them important, and spend time on them) has received less attention. The purpose of the present study was to examine the bidirectional longitudinal association between engagement in valued activities and adolescent positive adjustment (optimism, purpose in life, and self-esteem), as well as investigate a possible underlying mechanism for this link. High school students (N = 2,270, 48.7% female) from Ontario, Canada completed questionnaires annually in grades 10, 11, and 12. Auto-regressive cross-lagged path analyses were conducted over time, controlling for gender, parental education, and academic grades. Greater engagement in valued activities predicted higher optimism, purpose, and self-esteem over time. Importantly, the results did not support an alternate hypothesis of selection effects, in that adolescents who were better adjusted were not more likely than their peers to engage in valued activities over time. We also found that the longitudinal associations between valued activities and positive adjustment may be due partly to an underlying effect of increased positive mood. Thus, engagement in valued activities appears to be important for adolescent positive adjustment, and may help to foster thriving. Communities, educators, and parents should actively support and encourage adolescents to develop valued activities, and seek to ensure that there are ample opportunities and resources available for them to do so.

  14. Serum uric acid levels correlate with benign paroxysmal positional vertigo.

    PubMed

    Celikbilek, A; Gencer, Z K; Saydam, L; Zararsiz, G; Tanik, N; Ozkiris, M

    2014-01-01

    Benign paroxysmal positional vertigo (BPPV) is a frequently encountered condition that can severely affect the quality of life. In this study, we aimed to assess the possible relations between serum uric acid (SUA) levels and BPPV. Fifty patients with BPPV, and 40 age- and sex-matched control subjects were enrolled in the study. All the patients and controls underwent a complete audio-vestibular test battery including the Dix-Hallpike maneuver and supine roll test for posterior semicircular canal (PSC) and horizontal semicircular canal, respectively. Routine hematological and biochemical analyses were performed in both groups. In the BPPV group, measurements of SUA levels were repeated 1 month after the vertigo attack. The lipid profiles and SUA levels were higher in patients with BPPV than detected in controls (P < 0.05 and P < 0.001, respectively). Albumin and SUA values were independently associated with BPPV in multiple logistic regression models (P < 0.05 and P < 0.001, respectively). A cutoff value of 4 for SUA level with a sensitivity of 0.72 (0.58-0.84) and a specificity of 0.60 (0.43-0.75) was obtained in the receiver operating characteristic analyses. There was a significant decrement in SUA level 1 month after the vertigo attack compared with the values obtained during the attack (P < 0.001). Among the most involved type of BPPV (PSC BPPV), the right side was affected in 26 patients (57.8%) and the left side in 19 patients (42.2%). SUA levels did not differ statistically in patients with PSC BPPV for either the right or left sides (P > 0.05). Elevated SUA is positively correlated with BPPV, requiring further efforts to clarify the exact mechanism. © 2013 The Author(s) European Journal of Neurology © 2013 EFNS.

  15. Diagnostic capability of scanning laser polarimetry with variable cornea compensator in Indian patients with early primary open-angle glaucoma.

    PubMed

    Parikh, Rajul S; Parikh, Shefali R; Kumar, Rajesh S; Prabakaran, S; Babu, J Gansesh; Thomas, Ravi

    2008-07-01

    To evaluate the diagnostic ability of scanning laser polarimetry (GDx variable corneal compensator [VCC]) for early glaucoma in Asian Indian eyes. Cross-sectional observational study. Two groups of patients (early glaucoma and normal) who satisfied the inclusion and exclusion criteria were included. Early glaucoma was diagnosed in presence of open angles, characteristic glaucomatous optic disc changes correlating with the visual field (VF) on automated perimetry (VF defect fulfilling at least 2 of 3 Anderson and Patella's criteria with mean deviation >or= -6 decibels). Normal subjects had visual acuity >or= 20/30 and intraocular pressure < 22 mmHg, with a normal optic disc and fields and no ocular abnormality. All patients underwent complete ophthalmic evaluation, including VF examination (24-2/30-2 Swedish interactive threshold algorithm standard program) and imaging with GDx VCC. Sensitivity, specificity, positive predictive value and negative predictive value, area under the receiving operating characteristic curve, and likelihood ratios (LRs) were calculated for various GDx VCC parameters. Seventy-four eyes (74 patients) with early glaucoma and 104 eyes (104 normal subjects) were enrolled. TSNIT Std Dev (temporal-superior-nasal-inferior-temporal standard deviation) had the best combination of sensitivity and specificity-61.3 and 95.2, respectively-followed by nerve fiber index score > 50 (sensitivity, 52.7%; specificity, 99%). Nerve fiber index score > 50 had positive and negative predictive values of 74.3% and 97.6%, respectively, for an assumed glaucoma prevalence of 5%. Nerve fiber index score > 50 had a positive LR (+LR) of 54.8 for early glaucoma. GDx VCC has moderate sensitivity, with high specificity, in the diagnosis of early glaucoma. The high +LR for the nerve fiber index score can provide valuable diagnostic information for individual patients.

  16. ROCView: prototype software for data collection in jackknife alternative free-response receiver operating characteristic analysis

    PubMed Central

    Thompson, J; Hogg, P; Thompson, S; Manning, D; Szczepura, K

    2012-01-01

    ROCView has been developed as an image display and response capture (IDRC) solution to image display and consistent recording of reader responses in relation to the free-response receiver operating characteristic paradigm. A web-based solution to IDRC for observer response studies allows observations to be completed from any location, assuming that display performance and viewing conditions are consistent with the study being completed. The simplistic functionality of the software allows observations to be completed without supervision. ROCView can display images from multiple modalities, in a randomised order if required. Following registration, observers are prompted to begin their image evaluation. All data are recorded via mouse clicks, one to localise (mark) and one to score confidence (rate) using either an ordinal or continuous rating scale. Up to nine “mark-rating” pairs can be made per image. Unmarked images are given a default score of zero. Upon completion of the study, both true-positive and false-positive reports can be downloaded and adapted for analysis. ROCView has the potential to be a useful tool in the assessment of modality performance difference for a range of imaging methods. PMID:22573294

  17. Youth Development Outcomes of the Camp Experience: Evidence for Multidimensional Growth

    ERIC Educational Resources Information Center

    Thurber, Christopher A.; Scanlin, Marge M.; Scheuler, Leslie; Henderson, Karla A.

    2007-01-01

    Three thousand, three hundred and ninety-five families, whose child attended one of 80 different day or resident summer camps for at least one week, completed customized questionnaires that measured growth from precamp to postcamp in four domains: Positive Identity, Social Skills, Physical & Thinking Skills, and Positive Values & Spirituality.…

  18. PROPERTY APPRAISAL PROVIDES CONTROL, INSURANCE BASIS, AND VALUE ESTIMATE.

    ERIC Educational Resources Information Center

    THOMSON, JACK

    A COMPLETE PROPERTY APPRAISAL SERVES AS A BASIS FOR CONTROL, INSURANCE AND VALUE ESTIMATE. A PROFESSIONAL APPRAISAL FIRM SHOULD PERFORM THIS FUNCTION BECAUSE (1) IT IS FAMILIAR WITH PROPER METHODS, (2) IT CAN PREPARE THE REPORT WITH MINIMUM CONFUSION AND INTERRRUPTION OF THE COLLEGE OPERATION, (3) USE OF ITS PRICING LIBRARY REDUCES TIME NEEDED AND…

  19. Simultaneous qubit-loss-free fusion of three multiple W states

    NASA Astrophysics Data System (ADS)

    Wang, Meiyu; Hao, Quanzhi; Yan, Fengli; Gao, Ting

    2018-05-01

    Qubit-loss-free fusion for two W states introduced by Li K et al (2016 Phys. Rev. A 94 062315) clearly increases the final size of the obtained W state and greatly reduces the number of fusion steps to achieve a W state of a target size. Motivated by this idea, we propose a qubit-loss-free fusion scheme for fusing three polarization entangled W states simultaneously. The elements of a two-outcome positive-operator valued measurement and the appropriate joint unitary operation for realizing a positive-operator valued measurement measurement are given. As an example, with the assistance of weak cross-Kerr nonlinearities, an optical setup for fusing three W states is proposed. We analyze the success probability of the scheme and the resource cost of the present scheme, as compared to previous work.

  20. Hospital leadership perspectives on the contributions of Ronald McDonald Houses. Results from an international survey.

    PubMed

    Lantz, Paula M; Rubin, Nicole; Mauery, D Richard

    2015-01-01

    The purpose of this paper is to describe an international survey of hospital executives and administrators' perspectives on the contributions of their affiliation with a Ronald McDonald House (RMH) as an example of accommodation in family-centered care to the hospital's mission, operations and patient experience. RMHs worldwide provided the names and e-mail addresses of the people holding key leadership positions in their main hospital partner, who in turn were invited to complete an internet-based survey (530 participants; response rate of 54.5 percent). Hospital leaders reported very positive opinions about the contributions of their RMHs affiliation to their ability to serve seriously ill children and their families. This included such important outcomes as increasing family integrity and family participation in care decisions; and decreasing psychosocial stress and hospital social work resource burdens associated with lodging, food, transportation and sibling support. Hospital chief executive offices (CEOs) and medical directors reported very strong and positive opinions regarding the value-added of their RMHs affiliation in many areas, including enhanced marketing of hospital specialty services and reduced length of stay. Survey response bias is a limitation, although the results are still useful in terms of identifying multiple ways in which RMHs are perceived as contributing to hospitals' operations and provision of family-centered care. Overall, the results suggest that, internationally, hospital leaders believe that RMHs play a key and valued role in their provision of family-centered care to seriously ill children and their families. Family accommodation is more than the simple provision of lodging and plays an integral role how hospitals approach family-centered care. This international study contributes to the general literature on the role of family accommodation in hospitals' provision of family-centered care and the specific and very sparse literature on RMHs in particular.

  1. 40 CFR 265.1081 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... complete contact with it) inside a tank that has a fixed roof. Liquid-mounted seal means a foam or liquid... fluctuations. A safety device is designed to remain in a closed position during normal operations and open only...

  2. 40 CFR 265.1081 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... complete contact with it) inside a tank that has a fixed roof. Liquid-mounted seal means a foam or liquid... fluctuations. A safety device is designed to remain in a closed position during normal operations and open only...

  3. 40 CFR 265.1081 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... complete contact with it) inside a tank that has a fixed roof. Liquid-mounted seal means a foam or liquid... fluctuations. A safety device is designed to remain in a closed position during normal operations and open only...

  4. 40 CFR 265.1081 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... complete contact with it) inside a tank that has a fixed roof. Liquid-mounted seal means a foam or liquid... fluctuations. A safety device is designed to remain in a closed position during normal operations and open only...

  5. 40 CFR 265.1081 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... complete contact with it) inside a tank that has a fixed roof. Liquid-mounted seal means a foam or liquid... fluctuations. A safety device is designed to remain in a closed position during normal operations and open only...

  6. Agreement between pre-operative and intra-operative bacteriological samples in 85 chronic peri-prosthetic infections.

    PubMed

    Matter-Parrat, V; Ronde-Oustau, C; Boéri, C; Gaudias, J; Jenny, J-Y

    2017-04-01

    Whether pre-operative microbiological sampling contributes to the management of chronic peri-prosthetic infection remains controversial. We assessed agreement between the results of pre-operative and intra-operative samples in patients undergoing single-stage prosthesis exchange to treat chronic peri-prosthetic infection. Agreement between pre-operative and intra-operative samples exceeds 75% in patients undergoing single-stage exchange of a hip or knee prosthesis to treat chronic peri-prosthetic infection. This single-centre retrospective study included 85 single-stage prosthesis exchange procedures in 82 patients with chronic peri-prosthetic infection at the hip or knee. Agreement between pre-operative and intra-operative sample results was evaluated. Changes to the initial antibiotic regimen made based on the intra-operative sample results were recorded. Of 149 pre-operative samples, 109 yielded positive cultures, in 75/85 cases. Of 452 intra-operative samples, 354 yielded positive cultures, in 85/85 cases. Agreement was complete in 54 (63%) cases and partial in 9 (11%) cases; there was no agreement in the remaining 22 (26%) cases. The complete agreement rate was significantly lower than 75% (P=0.01). The initial antibiotic regimen was inadequate in a single case. Pre-operative sampling may contribute to the diagnosis of peri-prosthetic infection but is neither necessary nor sufficient to confirm the diagnosis and identify the causative agent. The spectrum of the initial antibiotic regimen cannot be safely narrowed based on the pre-operative sample results. We suggest the routine prescription of a probabilistic broad-spectrum antibiotic regimen immediately after the prosthesis exchange, even when a pathogen was identified before surgery. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. New constructions of approximately SIC-POVMs via difference sets

    NASA Astrophysics Data System (ADS)

    Luo, Gaojun; Cao, Xiwang

    2018-04-01

    In quantum information theory, symmetric informationally complete positive operator-valued measures (SIC-POVMs) are related to quantum state tomography (Caves et al., 2004), quantum cryptography (Fuchs and Sasaki, 2003) [1], and foundational studies (Fuchs, 2002) [2]. However, constructing SIC-POVMs is notoriously hard. Although some SIC-POVMs have been constructed numerically, there does not exist an infinite class of them. In this paper, we propose two constructions of approximately SIC-POVMs, where a small deviation from uniformity of the inner products is allowed. We employ difference sets to present the first construction and the dimension of the approximately SIC-POVMs is q + 1, where q is a prime power. Notably, the dimension of this framework is new. The second construction is based on partial geometric difference sets and works whenever the dimension of the framework is a prime power.

  8. SIC-POVMS and MUBS: Geometrical Relationships in Prime Dimension

    NASA Astrophysics Data System (ADS)

    Appleby, D. M.

    2009-03-01

    The paper concerns Weyl-Heisenberg covariant SIC-POVMs (symmetric informationally complete positive operator valued measures) and full sets of MUBs (mutually unbiased bases) in prime dimension. When represented as vectors in generalized Bloch space a SIC-POVM forms a d2-1 dimensional regular simplex (d being the Hilbert space dimension). By contrast, the generalized Bloch vectors representing a full set of MUBs form d+1 mutually orthogonal d-1 dimensional regular simplices. In this paper we show that, in the Weyl-Heisenberg case, there are some simple geometrical relationships between the single SIC-POVM simplex and the d+1 MUB simplices. We go on to give geometrical interpretations of the minimum uncertainty states introduced by Wootters and Sussman, and by Appleby, Dang and Fuchs, and of the fiduciality condition given by Appleby, Dang and Fuchs.

  9. Positive Traits Linked to Less Pain through Lower Pain Catastrophizing

    PubMed Central

    Hood, Anna; Pulvers, Kim; Carrillo, Janet; Merchant, Gina; Thomas, Marie

    2011-01-01

    The present study examined the association between positive traits, pain catastrophizing, and pain perceptions. We hypothesized that pain catastrophizing would mediate the relationship between positive traits and pain. First, participants (n = 114) completed the Trait Hope Scale, the Life Orientation Test- Revised, and the Pain Catastrophizing Scale. Participants then completed the experimental pain stimulus, a cold pressor task, by submerging their hand in a circulating water bath (0º Celsius) for as long as tolerable. Immediately following the task, participants completed the Short-Form McGill Pain Questionnaire (MPQ-SF). Pearson correlation found associations between hope and pain catastrophizing (r = −.41, p < .01) and MPQ-SF scores (r = −.20, p < .05). Optimism was significantly associated with pain catastrophizing (r = −.44, p < .01) and MPQ-SF scores (r = −.19, p < .05). Bootstrapping, a non-parametric resampling procedure, tested for mediation and supported our hypothesis that pain catastrophizing mediated the relationship between positive traits and MPQ-SF pain report. To our knowledge, this investigation is the first to establish that the protective link between positive traits and experimental pain operates through lower pain catastrophizing. PMID:22199416

  10. Time-dependent middle ear pressure changes under general anaesthesia in children: N2O-O2 mixture versus air-oxygen mixture.

    PubMed

    Apan, A; Muluk, N Bayar; Güler, S; Budak, B

    2013-01-01

    The aim of this study was to investigate the effects of N2O-O2 mixture (Inspired O2 30%) on middle ear pressure (MEP) in children compared with the effects of an air-oxygen mixture (Inspired O2 50%). The study included thirty child patients who underwent general anaesthesia for different reasons, with the exception of ENT problems and ear interventions. They were randomly divided into two groups. Group 1 (15 children: 10 male and 5 female) received a N2O-O2 mixture (Inspired O2 30%); and group 2 (15 children: 10 male and 5 female) were given an air-oxygen mixture (Inspired O2 50%). MEP was measured using a portable impedance analyser before the operation (PreO),10 minutes after intubation (10AEn), 30 minutes after intubation (30AEn), 10 minutes before extubation (10BEx), 15 minutes after the operation (PO15), 30 minutes after the operation (PO30), 1 hour after the operation (PO1h) and 6 hours after the operation (PO6h). The pressure and compliance values were the same in groups 1 and 2. The pressure-time graphs for the two groups were different: in Group 2, MEP rose quickly at 10AEn and positive pressure values were seen in the middle ear. MEP then fell rapidly until the end of the surgery and lower and negative pressures (Mean -50 daPa) were observed at PO6h. In Group 1, MEP was elevated at 10AEn and positive pressure was found (but not as high as in Group 2). MEP then fell more slowly. In other words, positive pressure in the middle ear persisted longer and the middle ear was subjected to positive pressure and nitrogen over a longer period. Separate analyses were made in Groups 1 and 2 of pressure differences and of compliance values at eight measurement points using the Friedman test. Differences in pressure values were found to be statistically significant in both Group 1 (p = 0.000) and Group 2 (p = 0.000). In Group 1, all the 10AEn and 30AEn values were significantly higher than the PreO, PO30, PO1h and PO6h values. The 10BEx value was significantly higher than the PreO and PO1h values. The PO15 value was significantly higher than the PreO value. In Group 2, the PO6h value was significantly lower than the 10BEx, 10AEn and 30AEn values. The PO1h value was significantly lower than the 30AEn values. The MEP values increased in Group 1 in younger and taller children and in children receiving anaesthesia for shorter periods. MEP values increased in Group 2 in younger and taller children, and in heavier children. MEP values fell with the length of anaesthesia. In brief anaesthesia, nitrogen was not removed from the middle ear quickly in Group 1: middle ear pressure values were higher. The nitrous oxide remained in the middle ear longer and so the possibility of ear toxicity may increase. In Group 2, 50% O2 was rapidly absorbed and removed from the middle ear and so middle ear pressure was not as high. It may be concluded that air-oxygen mixture (Inspired O2 50%) anaesthesia should be recommended as being more reliable in tympanoplasties and other middle ear interventions than a N2O-O2 mixture (Inspired O2 30%).

  11. Evaluation of a radiation protection cabin for invasive electrophysiological procedures.

    PubMed

    Dragusin, Octavian; Weerasooriya, Rukshen; Jaïs, Pierre; Hocini, Mélèze; Ector, Joris; Takahashi, Yoshihide; Haïssaguerre, Michel; Bosmans, Hilde; Heidbüchel, Hein

    2007-01-01

    Complex invasive electrophysiological procedures may result in high cumulative operator radiation exposure. Classical protection with lead aprons results in discomfort while radioprotection is still incomplete. This study evaluated the usefulness of a radiation protection cabin (RPC) that completely surrounds the operator. The evaluation was performed independently in two electrophysiology laboratories (E1-Leuven, Belgium; E2-Bordeaux, France), comparing operator radiation exposure using the RPC vs. a 0.5 mm lead-equivalent apron (total of 135 procedures). E1 used thermoluminiscent dosimeters (TLDs) placed at 16 positions in and out of the RPC and nine positions in and out of the apron. E2 used more sensitive electronic personal dosimeters (EPD), placed at waist and neck. The sensitivity thresholds of the TLDs and EPDs were 10-20 microSv and 1-1.5 microSv, respectively. All procedures could be performed unimpeded with the RPC. Median TLD dose values outside protected areas were in the range of 57-452 microSv, whereas doses under the apron or inside the RPC were all at the background radiation level, irrespective of procedure and fluoroscopy duration and of radiation energy delivered. In addition, the RPC was protecting the entire body (except the hands), whereas lead apron protection is incomplete. Also with the more sensitive EPDs, the radiation dose within the RPC was at the sensitivity threshold/background level (1.3+/-0.6 microSv). Again, radiation to the head was significantly lower within the RPC (1.9+/-1.2 microSv) than with the apron (102+/-23 microSv, P<0.001). The use of the RPC allows performing catheter ablation procedures without compromising catheter manipulation, and with negligible radiation exposure for the operator.

  12. Clinical impacts of oral gastrografin follow-through in adhesive small bowel obstruction (SBO).

    PubMed

    Farid, Mohammed; Fikry, Amir; El Nakeeb, Ayman; Fouda, Elyamani; Elmetwally, Tito; Yousef, Mohammed; Omar, Waleed

    2010-08-01

    Many studies have shown that gastrografin can be used for diagnosis of adhesive small bowel obstruction (ASBO) and for assessing the need for surgical intervention. However, several studies have reported conflicting results. Therefore, the aim of this study is to assess the diagnostic and therapeutic effect of gastrografin in ASBO. Altogether, 110 patients with ASBO were randomized into control and gastrografin groups. In the gastrografin group, 100 mL of the dye was administered through a nasogastric tube. Obstruction was considered complete if the contrast failed to reach the colon on the 24-h film. Patients with gastrografin in the colon within 24 h after dye administration were considered as partially obstructed, and were submitted to nonoperative treatment. The patients were operated on if they developed signs of strangulation or failed to improve within 48 h. The overall operative rate was 14.5% in gastrografin group versus 34.5% in control group, P=0.04. The time from admission to resolution of symptoms was significantly lower in gastrografin group (19.5 versus 42.6 h, P=0.001), and the length of hospital stay was shorter in gastrografin group (3.8 versus 6.9 d 0.002), and in nonoperative patients (3.1 versus 5.1 days). Sensitivity, specificity, positive predictive value, and negative predictive value for gastrografin follow-through as an indicator for operative treatment of ASBO were 87.5%, 100%, 100 % , and 97.9%, respectively. Oral gastrografin helps in the management of ASBO. Oral gastrografin is safe and reduces the operative rate and time of resolution as well as hospital stay. Copyright 2010 Elsevier Inc. All rights reserved.

  13. Children's motivation in elementary physical education: an expectancy-value model of achievement choice.

    PubMed

    Xiang, Ping; McBride, Ron; Guan, Jianmin; Solmon, Melinda

    2003-03-01

    This study examined children's motivation in elementary physical education within an expectancy-value model developed by Eccles and her colleagues. Four hundred fourteen students in second and fourth grades completed questionnaires assessing their expectancy-related beliefs, subjective task values, and intention for future participation in physical education. Results indicated that expectancy-related beliefs and subjective task values were clearly distinguishable from one another across physical education and throwing. The two constructs were related to each other positively. Children's intention for future participation in physical education was positively associated with their subjective task values and/or expectancy-related beliefs. Younger children had higher motivation for learning in physical education than older children. Gender differences emerged and the findings provided empirical evidence supporting the validity of the expectancy-value model in elementary physical education.

  14. Correlation of skin test results and specific immunoglobulin E blood levels with nasal provocation testing for house-dust mite allergies.

    PubMed

    Haxel, Boris R; Huppertz, Tilman; Boessert, Patrick; Bast, Florian; Fruth, Kai

    2016-01-01

    Allergen-specific immunotherapy for house-dust mite (HDM) allergies is associated with lower success rates when compared with similar treatments for other inhalant allergens, such as grass or birch. One reason might be the greater difficulty in diagnosing patients with assumed HDM allergies because symptoms occur perennially and may differ from those of a conventional allergic rhinitis. The aim of the study was to compare the different methods of diagnosis in patients with assumed HDM allergy. We performed a retrospective analysis of nasal provocation tests (NPT) from patients (n = 161) evaluated for Dermatophagoides pteronyssinus (n = 127) and Dermatophagoides farinae (n = 104) allergies, and compared the results with other allergen testing methods (skin-prick test [SPT], intracutaneous test, and allergen specific immunoglobulin E levels [sIgE] to detect sensitization). Receiver operating characteristic curves were used for the analyses and the areas under the curve were calculated. For D. pteronyssinus and D. farinae, 86 and 70 complete data files, respectively, were available. For both tested HDMs, the results of the receiver operating characteristic curves showed a significant correlation for SPT and sIgE, with the results of the NPT (area under the curve, 0.742 to 0.763) but not for the intracutaneous test. In patients with a positive SPT (≥3 mm), an allergy was confirmed by the NPT in 69% of cases for D. pteronyssinus and 71% for D. farinae. A positive sIgE result (ImmunoCAP class of ≥2) was verified by the NPT in 69% of cases (D. pteronyssinus) and 70% (D. farinae). The predictability value for a positive NPT result is best for SPT and sIgE. Nevertheless, even if the results of both test systems are combined, the positive predictive value that was achieved was only 0.77 for D. pteronyssinus and 0.69 for D. farinae. Therefore, in patients eligible for immunotherapy for HDM, an NPT should be performed before the start of the therapy to verify a clinically relevant allergy.

  15. Well development by jetting using coiled tubing and simultaneous pumping.

    PubMed

    Rosberg, Jan-Erik; Bjelm, Leif

    2009-01-01

    During flow testing of a deep, 1927-m, gravel packed screen completed well, it became apparent that well development was needed to increase productivity. A hydrojetting system using coiled tubing in combination with simultaneous pumping was developed and tested and found to be successful. To verify whether the jetting improved the well, the results of a pumping test conducted before and after the jetting operation are compared. In addition, flowmeter logging and hydraulic properties obtained from pumping tests conducted during the jetting operation were also used to verify the improvements. Hydrojetting in combination with simultaneous pumping proved to be an effective cleaning method. After 100 min of pumping, around 110 m less drawdown and 15 L/s higher average flow rate were obtained compared to the values before the jetting operation. The skin factor was positive before the jetting operation and negative thereafter, thus providing additional evidence of improvements of the well. The flowmeter data also confirmed the improvements and were valuable in optimizing the jetting operation. It was also found, from the short-term pumping tests conducted during the jetting operation, that the Hantush-Jacob method for leaky confined aquifers is a valuable indicator of the well development. The combination of methods used for the well development in this case can easily be applied on other deep well projects to obtain a controlled and time-efficient well development. Copyright © 2009 The Author(s). Journal Compilation © 2009 National Ground Water Association.

  16. Systems and methods for thermal imaging technique for measuring mixing of fluids

    DOEpatents

    Booten, Charles; Tomerlin, Jeff; Winkler, Jon

    2016-06-14

    Systems and methods for thermal imaging for measuring mixing of fluids are provided. In one embodiment, a method for measuring mixing of gaseous fluids using thermal imaging comprises: positioning a thermal test medium parallel to a direction gaseous fluid flow from an outlet vent of a momentum source, wherein when the source is operating, the fluid flows across a surface of the medium; obtaining an ambient temperature value from a baseline thermal image of the surface; obtaining at least one operational thermal image of the surface when the fluid is flowing from the outlet vent across the surface, wherein the fluid has a temperature different than the ambient temperature; and calculating at least one temperature-difference fraction associated with at least a first position on the surface based on a difference between temperature measurements obtained from the at least one operational thermal image and the ambient temperature value.

  17. Radiation in the earth's atmosphere: its radiance, polarization, and ellipticity.

    PubMed

    Hitzfelder, S J; Plass, G N; Kattawar, G W

    1976-10-01

    The complete radiation field including polarization is calculated by the matrix operator method for a model of the real atmosphere. The radiance, direction and amount of polarization, and ellipticity are obtained at the top and bottom of the atmosphere for three values of the surface albedo (0, 0.15, 0.90) and five solar zenith angles. Scattering and absorption by molecules (including ozone) and by aerosols are taken into account together with the variation of the number density of these substances with height. All results are calculated for both a normal aerosol number and a distribution that is one-third of the normal amount at all heights. The calculated values show general qualitative agreement with the available experimental measurements. The position of the neutral points of the polarization in the principal plane is a sensitive indicator of the characteristics of the aerosol particles in the atmosphere, since it depends on the sign and value of the single scattered polarization for scattering angles around 20 degrees and 160 degrees for transmitted and reflected photons, respectively. This, in turn, depends on the index of refraction and size distribution of the aerosols. The neutral point position does not depend appreciably on the surface albedo and, over a considerable range, depends little on the solar zenith angle. The value of the maximum polarization in the principal plane depends on the aerosol amount, surface albedo, and solar zenith angle. It could be used to measure the aerosol amount. The details of the ellipticity curves are similar to those for scattering from pure aerosol layers and, thus, are little modified by the Rayleigh scattering. Aerosols could be identified by their characteristic ellipticity curves.

  18. GPS-PWV Estimation and Analysis for CGPS Sites Operating in Mexico

    NASA Astrophysics Data System (ADS)

    Gutierrez, O.; Vazquez, G. E.; Bennett, R. A.; Adams, D. K.

    2014-12-01

    Eighty permanent Global Positioning System (GPS) tracking stations that belong to several networks spanning Mexico intended for diverse purposes and applications were used to estimate precipitable water vapor (PWV) using measurement series covering the period of 2000-2014. We extracted the GPS-PWV from the ionosphere-free double-difference carrier phase observations, processed using the GAMIT software. The GPS data were processed with a 30 s sampling rate, 15-degree cutoff angle, and precise GPS orbits disseminated by IGS. The time-varying part of the zenith wet delay was estimated using the Global Mapping Function (GMF), while the constant part is evaluated using the Neil tropospheric model. The data reduction to compute the zenith wet delay follows the step piecewise linear strategy, which is subsequently transformed to PWV estimated every 2-hr. Although there exist previous isolated studies for estimating PWV in Mexico, this study is an attempt to perform a more complete and comprehensive analysis of PWV estimation throughout the Mexican territory. Our resulting GPS-based PWV were compared to available PWV values for 30 stations that operate in Mexico and report the PWV to Suominet. This comparison revealed differences of 1 to 2 mm between the GPS-PWV solution and the PWV reported by Suominet. Accurate values of GPS-PWV will help enhance Mexico ability to investigate water vapor advection, convective and frontal rainfall and long-term climate variability.

  19. Predicting Likelihood of Having Four or More Positive Nodes in Patient With Sentinel Lymph Node-Positive Breast Cancer: A Nomogram Validation Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unal, Bulent; Gur, Akif Serhat; Beriwal, Sushil

    2009-11-15

    Purpose: Katz suggested a nomogram for predicting having four or more positive nodes in sentinel lymph node (SLN)-positive breast cancer patients. The findings from this formula might influence adjuvant radiotherapy decisions. Our goal was to validate the accuracy of the Katz nomogram. Methods and Materials: We reviewed the records of 309 patients with breast cancer who had undergone completion axillary lymph node dissection. The factors associated with the likelihood of having four or more positive axillary nodes were evaluated in patients with one to three positive SLNs. The nomogram developed by Katz was applied to our data set. The areamore » under the curve of the corresponding receiver operating characteristics curve was calculated for the nomogram. Results: Of the 309 patients, 80 (25.9%) had four or more positive axillary lymph nodes. On multivariate analysis, the number of positive SLNs (p < .0001), overall metastasis size (p = .019), primary tumor size (p = .0001), and extracapsular extension (p = .01) were significant factors predicting for four or more positive nodes. For patients with <5% probability, 90.3% had fewer than four positive nodes and 9.7% had four or more positive nodes. The negative predictive value was 91.7%, and sensitivity was 80%. The nomogram was accurate and discriminating (area under the curve, .801). Conclusion: The probability of four or more involved nodes is significantly greater in patients who have an increased number of positive SLNs, increased overall metastasis size, increased tumor size, and extracapsular extension. The Katz nomogram was validated in our patients. This nomogram will be helpful to clinicians making adjuvant treatment recommendations to their patients.« less

  20. Propulsion Technology Lifecycle Operational Analysis

    NASA Technical Reports Server (NTRS)

    Robinson, John W.; Rhodes, Russell E.

    2010-01-01

    The paper presents the results of a focused effort performed by the members of the Space Propulsion Synergy Team (SPST) Functional Requirements Sub-team to develop propulsion data to support Advanced Technology Lifecycle Analysis System (ATLAS). This is a spreadsheet application to analyze the impact of technology decisions at a system-of-systems level. Results are summarized in an Excel workbook we call the Technology Tool Box (TTB). The TTB provides data for technology performance, operations, and programmatic parameters in the form of a library of technical information to support analysis tools and/or models. The lifecycle of technologies can be analyzed from this data and particularly useful for system operations involving long running missions. The propulsion technologies in this paper are listed against Chemical Rocket Engines in a Work Breakdown Structure (WBS) format. The overall effort involved establishing four elements: (1) A general purpose Functional System Breakdown Structure (FSBS). (2) Operational Requirements for Rocket Engines. (3) Technology Metric Values associated with Operating Systems (4) Work Breakdown Structure (WBS) of Chemical Rocket Engines The list of Chemical Rocket Engines identified in the WBS is by no means complete. It is planned to update the TTB with a more complete list of available Chemical Rocket Engines for United States (US) engines and add the Foreign rocket engines to the WBS which are available to NASA and the Aerospace Industry. The Operational Technology Metric Values were derived by the SPST Sub-team in the form of the TTB and establishes a database for users to help evaluate and establish the technology level of each Chemical Rocket Engine in the database. The Technology Metric Values will serve as a guide to help determine which rocket engine to invest technology money in for future development.

  1. USAF Inorganic Coating Successes

    DTIC Science & Technology

    2012-08-01

    Sodium dichromate solution, 50 parts per million Benchmark Permanganate Seal Candidate 1 Low Nickel Seal (with a hot water seal) Candidate 2A Low...requested by OO-ALC • Continue assisting OO-ALC with implementing permanganate sealer – Received approval from Engineering Review Board (ERB...to use the permanganate seal for Type II anodizing operations • Position OO-ALC for a completely Cr-free surface finishing operation – Anodizing

  2. The influence of a Classroom Model of Scientific Scholarship on Four Girls' Trajectories of Identification with Science

    NASA Astrophysics Data System (ADS)

    Cook, Melissa Sunshine

    This study examines the teacher's role in shaping the identity construction resources available in a classroom and the ways in which individual students take up, modify, and appropriate those resources to construct themselves as scientists through interaction with their teacher and peers. Drawing on frameworks of identity construction and social positioning, I propose that the locally-negotiated classroom-level cultural model of what it means to be a "good" science student forms the arena in which students construct a sense of their own competence at, affiliation with, and interest in science. The setting for this study was a 6th grade science class at a progressive urban elementary school whose population roughly represents the ethnic and socioeconomic diversity of the state of California. The teacher was an experienced science and math teacher interested in social justice and inquiry teaching. Drawing from naturalistic observations, video and artifact analysis, survey data, and repeated interviews with students and the teacher, I demonstrated what it meant to be a "good" science student in this particular cultural community by analyzing what was required, reinforced, and rewarded in this classroom. Next, I traced the influence of this particular classroom's conception of what it meant to be good at science on the trajectories of identification with science of four 6th grade girls selected to represent a variety of stances towards science, levels of classroom participation, and personal backgrounds. Scientific scholarship in this class had two parts: values related to science as a discipline, and a more generic set of school-related values one might see in any classroom. Different meanings of and values for science were indexed in the everyday activities of the classroom: science as a language for describing the natural world, science as a set of rhetorical values, science as an adult social community, and science as a place for mess and explosions. Among school-related values, participation, cooperation, and completing work were most important. Individual students leveraged different aspects of the local cultural model of scientific scholarship to construct themselves as competent participants in the science classroom. This study extends and complicates current analyses of classroom norms by showing that to understand identity construction, we must do more than identify a list of norms operating in a classroom---we must map the relationships between norms. This analysis demonstrates how broader discourses, in this case about schooling and science, infiltrated the classroom and influenced the meaning and operation of classroom norms and individual students' efforts to position themselves in relation to the classroom model of a good student. Finally, these findings show the value in examining recognition from three interrelated lenses: self-narratives, other-narratives, and observational accounts of positioning.

  3. Hold Firm: Gifted Learners Value Standing One's Ground in Disagreements with a Friend

    ERIC Educational Resources Information Center

    Chichekian, Tanya; Shore, Bruce M.

    2017-01-01

    Seventy-four students in three different Grade 9 classrooms of high-performing learners from the same suburban, comprehensive secondary school, completed a questionnaire focused on their preferences for a friend to stand by his or her position in case of a disagreement, to maintain their own position themselves, and to modify their own stance.…

  4. A New Wideband, Fully Steerable, Decametric Array at Clark Lake

    NASA Technical Reports Server (NTRS)

    Erickson, W. C.; Fisher, J. R.

    1974-01-01

    A fully steerable, decametric array for radio astronomy is under construction at the Clark Lake Radio Observatory near Borrego Springs, California. This array will be a T of 720 conical spiral antennas (teepee-shaped antennas, hence the array is called the TPT), 3.0 km by 1.8 km capable of operating between 15 and 125 MHz. Both its operating frequency and beam position will be adjustable in less than one millisecond, and the TPT will provide a 49-element picture around the central beam position for extended source observations. Considerable experience was gained in the operation of completed portions of the array, and successful operation of the final array is assured. The results are described of the tests which were conducted with the conical spirals, and the planned electronics and data processing systems are described.

  5. Performance of magnetic resonance imaging in the evaluation of first-time and reoperative primary hyperparathyroidism.

    PubMed

    Kluijfhout, Wouter P; Venkatesh, Shriya; Beninato, Toni; Vriens, Menno R; Duh, Quan-Yang; Wilson, David M; Hope, Thomas A; Suh, Insoo

    2016-09-01

    Preoperative imaging in patients with primary hyperparathyroidism and a previous parathyroid operation is essential; however, performance of conventional imaging is poor in this subgroup. Magnetic resonance imaging appears to be a good alternative, though overall evidence remains scarce. We retrospectively investigated the performance of magnetic resonance imaging in patients with and without a previous parathyroid operation, with a separate comparison for dynamic gadolinium-enhanced magnetic resonance imaging. All patients undergoing magnetic resonance imaging prior to parathyroidectomy for primary hyperparathyroidism (first time or recurrent) between January 2000 and August 2015 at a high-volume, tertiary care, referral center for endocrine operations were included. We compared the sensitivity and positive predictive value of magnetic resonance imaging with conventional ultrasound and sestamibi on a per-lesion level. A total of 3,450 patients underwent parathyroidectomy, of which 84 patients with recurrent (n = 10) or persistent (n = 74) disease and 41 patients with a primary operation were included. Magnetic resonance imaging had a sensitivity and positive predictive value of 79.9% and 84.7%, respectively, and performance was good in both patients with and without a previous parathyroid operation. Adding magnetic resonance imaging to the combination of ultrasound and sestamibi resulted in a significant increase in sensitivity from 75.2% to 91.5%. Dynamic magnetic resonance imaging produced excellent results in the reoperative group, with sensitivity and a positive predictive value of 90.1%. Technologic advances have enabled faster and more accurate magnetic resonance imaging protocols, making magnetic resonance imaging an excellent alternative modality without associated ionizing radiation. Our study shows that the sensitivity of multimodality imaging for parathyroid adenomas improved significantly with the use of conventional and dynamic magnetic resonance imaging, even in the case of recurrent or persistent disease. Published by Elsevier Inc.

  6. Public transit design for smart growth : using choice experiments to quantify tradeoffs, values and funding implications.

    DOT National Transportation Integrated Search

    2011-03-01

    Studying public perception of public transportation and the environment in which it operates is crucial to understanding the symbiotic relationship : between transportation and the built environment. This report documents research completed to quanti...

  7. Does a robotic scrub nurse improve economy of movements?

    NASA Astrophysics Data System (ADS)

    Wachs, Juan P.; Jacob, Mithun; Li, Yu-Ting; Akingba, George

    2012-02-01

    Objective: Robotic assistance during surgery has been shown to be a useful resource to both augment the surgical skills of the surgeon through tele-operation, and to assist the surgeon handling the surgical instruments to the surgeon, similar to a surgical tech. We evaluated the performance and effect of a gesture driven surgical robotic nurse in the context of economy of movements, during an abdominal incision and closure exercise with a simulator. Methods: A longitudinal midline incision (100 mm) was performed on the simulated abdominal wall to enter the peritoneal cavity without damaging the internal organs. The wound was then closed using a blunt needle ensuring that no tissue is caught up by the suture material. All the instruments required to complete this task were delivered by a robotic surgical manipulator directly to the surgeon. The instruments were requested through voice and gesture recognition. The robotic system used a low end range sensor camera to extract the hand poses and for recognizing the gestures. The instruments were delivered to the vicinity of the patient, at chest height and at a reachable distance to the surgeon. Task performance measures for each of three abdominal incision and closure exercises were measured and compared to a human scrub nurse instrument delivery action. Picking instrument position variance, completion time and trajectory of the hand were recorded for further analysis. Results: The variance of the position of the robotic tip when delivering the surgical instrument is compared to the same position when a human delivers the instrument. The variance was found to be 88.86% smaller compared to the human delivery group. The mean task completion time to complete the surgical exercise was 162.7+/- 10.1 secs for the human assistant and 191.6+/- 3.3 secs (P<.01) when using the robotic standard display group. Conclusion: Multimodal robotic scrub nurse assistant improves the surgical procedure by reducing the number of movements (lower variance in the picking position). The variance of the picking point is closely related to the concept of economy of movements in the operating room. Improving the effectiveness of the operating room can potentially enhance the safety of surgical interventions without affecting the performance time.

  8. Imaging System for Vaginal Surgery.

    PubMed

    Taylor, G Bernard; Myers, Erinn M

    2015-12-01

    The vaginal surgeon is challenged with performing complex procedures within a surgical field of limited light and exposure. The video telescopic operating microscope is an illumination and imaging system that provides visualization during open surgical procedures with a limited field of view. The imaging system is positioned within the surgical field and then secured to the operating room table with a maneuverable holding arm. A high-definition camera and Xenon light source allow transmission of the magnified image to a high-definition monitor in the operating room. The monitor screen is positioned above the patient for the surgeon and assistants to view real time throughout the operation. The video telescopic operating microscope system was used to provide surgical illumination and magnification during total vaginal hysterectomy and salpingectomy, midurethral sling, and release of vaginal scar procedures. All procedures were completed without complications. The video telescopic operating microscope provided illumination of the vaginal operative field and display of the magnified image onto high-definition monitors in the operating room for the surgeon and staff to simultaneously view the procedures. The video telescopic operating microscope provides high-definition display, magnification, and illumination during vaginal surgery.

  9. Flight and Operational Medicine Clinic (FOMC) Task Process Mapping

    DTIC Science & Technology

    2014-03-01

    technicians, nurses, and physician assistants to accomplish the majority of the tasks; physician level tasks are few and primarily involve application of...condition 31, 37, 81? Complete evaluation Present 469 within 5 days of positive pregnancy test Is condition duty/fitness? NO End Process YES Send to ...info to Health IT Ancillary exam module provides requirements/ sends info to Health IT (Audiology, Optometry, Dental , Mental Health) Operational

  10. Optimal waist circumference cutoff value for defining the metabolic syndrome in postmenopausal Latin American women.

    PubMed

    Blümel, Juan E; Legorreta, Deborah; Chedraui, Peter; Ayala, Felix; Bencosme, Ascanio; Danckers, Luis; Lange, Diego; Espinoza, Maria T; Gomez, Gustavo; Grandia, Elena; Izaguirre, Humberto; Manriquez, Valentin; Martino, Mabel; Navarro, Daysi; Ojeda, Eliana; Onatra, William; Pozzo, Estela; Prada, Mariela; Royer, Monique; Saavedra, Javier M; Sayegh, Fabiana; Tserotas, Konstantinos; Vallejo, Maria S; Zuñiga, Cristina

    2012-04-01

    The aim of this study was to determine an optimal waist circumference (WC) cutoff value for defining the metabolic syndrome (METS) in postmenopausal Latin American women. A total of 3,965 postmenopausal women (age, 45-64 y), with self-reported good health, attending routine consultation at 12 gynecological centers in major Latin American cities were included in this cross-sectional study. Modified guidelines of the US National Cholesterol Education Program, Adult Treatment Panel III were used to assess METS risk factors. Receiver operator characteristic curve analysis was used to obtain an optimal WC cutoff value best predicting at least two other METS components. Optimal cutoff values were calculated by plotting the true-positive rate (sensitivity) against the false-positive rate (1 - specificity). In addition, total accuracy, distance to receiver operator characteristic curve, and the Youden Index were calculated. Of the participants, 51.6% (n = 2,047) were identified as having two or more nonadipose METS risk components (excluding a positive WC component). These women were older, had more years since menopause onset, used hormone therapy less frequently, and had higher body mass indices than women with fewer metabolic risk factors. The optimal WC cutoff value best predicting at least two other METS components was determined to be 88 cm, equal to that defined by the Adult Treatment Panel III. A WC cutoff value of 88 cm is optimal for defining METS in this postmenopausal Latin American series.

  11. Fatty liver index and hepatic steatosis index for prediction of non-alcoholic fatty liver disease in type 1 diabetes.

    PubMed

    Sviklāne, Laura; Olmane, Evija; Dzērve, Zane; Kupčs, Kārlis; Pīrāgs, Valdis; Sokolovska, Jeļizaveta

    2018-01-01

    Little is known about the diagnostic value of hepatic steatosis index (HSI) and fatty liver index (FLI), as well as their link to metabolic syndrome in type 1 diabetes mellitus. We have screened the effectiveness of FLI and HSI in an observational pilot study of 40 patients with type 1 diabetes. FLI and HSI were calculated for 201 patients with type 1 diabetes. Forty patients with FLI/HSI values corresponding to different risk of liver steatosis were invited for liver magnetic resonance study. In-phase/opposed-phase technique of magnetic resonance was used. Accuracy of indices was assessed from the area under the receiver operating characteristic curve. Twelve (30.0%) patients had liver steatosis. For FLI, sensitivity was 90%; specificity, 74%; positive likelihood ratio, 3.46; negative likelihood ratio, 0.14; positive predictive value, 0.64; and negative predictive value, 0.93. For HSI, sensitivity was 86%; specificity, 66%; positive likelihood ratio, 1.95; negative likelihood ratio, 0.21; positive predictive value, 0.50; and negative predictive value, 0.92. Area under the receiver operating characteristic curve for FLI was 0.86 (95% confidence interval [0.72; 0.99]); for HSI 0.75 [0.58; 0.91]. Liver fat correlated with liver enzymes, waist circumference, triglycerides, and C-reactive protein. FLI correlated with C-reactive protein, liver enzymes, and blood pressure. HSI correlated with waist circumference and C-reactive protein. FLI ≥ 60 and HSI ≥ 36 were significantly associated with metabolic syndrome and nephropathy. The tested indices, especially FLI, can serve as surrogate markers for liver fat content and metabolic syndrome in type 1 diabetes. © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  12. Resilient Control and Intrusion Detection for SCADA Systems

    DTIC Science & Technology

    2014-05-01

    Control. McGraw-Hill, 1996. [89] L. Greenemeier. Robots arrive at fukushima nuclear site with unclear mission. Scientific American, 2011. [90] M. Grimes...security engineering task. SCADA systems are hard real-time systems [251] because the completion of an operation after its deadline is considered useless and...that the attacker, after gaining unauthenticated access, could change the operator display values so that when an alarm actually goes off, the human

  13. Extended space expectation values in quantum dynamical system evolutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demiralp, Metin

    2014-10-06

    The time variant power series expansion for the expectation value of a given quantum dynamical operator is well-known and well-investigated issue in quantum dynamics. However, depending on the operator and Hamiltonian singularities this expansion either may not exist or may not converge for all time instances except the beginning of the evolution. This work focuses on this issue and seeks certain cures for the negativities. We work in the extended space obtained by adding all images of the initial wave function under the system Hamiltonian’s positive integer powers. This requires the introduction of certain appropriately defined weight operators. The resultingmore » better convergence in the temporal power series urges us to call the new defined entities “extended space expectation values” even though they are constructed over certain weight operators and are somehow pseudo expectation values.« less

  14. Factor Analysis of a Questionnaire Used for Developing an Operational Philosophy for Habilitation Facilities.

    ERIC Educational Resources Information Center

    Meadows, Denis; Tehan, Gerry

    1985-01-01

    Value questionnaires were developed and completed by 358 staff of activity therapy centers, which provide vocational and social training to disabled adults. Factor loadings of the questionnaire, designed to explore attitudes toward habilitation are reported. (CL)

  15. The effects of taboo-related distraction on driving performance.

    PubMed

    Chan, Michelle; Madan, Christopher R; Singhal, Anthony

    2016-07-01

    Roadside billboards containing negative and positive emotional content have been shown to influence driving performance, however, the impact of highly arousing taboo information is unknown. Taboo information more reliably evokes emotional arousal and can lead to greater attentional capture due to its inherent 'shock value.' The objective of the present study was to examine driver distraction associated with four types of information presented on roadside billboards: highly arousing taboo words, moderately arousing positive and negative words, and non-arousing neutral words. Participants viewed blocks of taboo, positive, negative and neutral words presented on roadside billboards while operating a driving simulator. They also responded to target (household-related) words by pressing a button on the steering wheel. At the end of the session, a surprise recall task was completed for all the words they saw while driving. Results showed that taboo words captured the most attention as revealed by better memory recall compared to all the other word types. Interestingly, taboo words were associated with better lane control compared to the other word types. We suggest that taboo-related arousal can enhance attentional focus during a complex task like simulated driving. That is, in a highly arousing situation, attention is selectively narrowed to the road ahead, resulting in better lane control. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. A RANDOM-SCAN DISPLAY OF PREDICTED SATELLITE POSITIONS.

    DTIC Science & Technology

    With the completion of the NRL evaluation of the experimental model of the Satellite Position Prediction and Display equipment ( SPAD ), efforts were...directed toward the design of an operational version of SPAD . Possible design and equipment configurations were proposed which would lead to a...substantial savings in cost and reduced equipment complexity. These designs involve the displaying of the SPAD information by means of a random scanning of

  17. Effects of Prone Position and Positive End-Expiratory Pressure on Noninvasive Estimators of ICP: A Pilot Study.

    PubMed

    Robba, Chiara; Bragazzi, Nicola Luigi; Bertuccio, Alessandro; Cardim, Danilo; Donnelly, Joseph; Sekhon, Mypinder; Lavinio, Andrea; Duane, Derek; Burnstein, Rowan; Matta, Basil; Bacigaluppi, Susanna; Lattuada, Marco; Czosnyka, Marek

    2017-07-01

    Prone positioning and positive end-expiratory pressure can improve pulmonary gas exchange and respiratory mechanics. However, they may be associated with the development of intracranial hypertension. Intracranial pressure (ICP) can be noninvasively estimated from the sonographic measurement of the optic nerve sheath diameter (ONSD) and from the transcranial Doppler analysis of the pulsatility (ICPPI) and the diastolic component (ICPFVd) of the velocity waveform. The effect of the prone positioning and positive end-expiratory pressure on ONSD, ICPFVd, and ICPPI was assessed in a prospective study of 30 patients undergoing spine surgery. One-way repeated measures analysis of variance, fixed-effect multivariate regression models, and receiver operating characteristic analyses were used to analyze numerical data. The mean values of ONSD, ICPFVd, and ICPPI significantly increased after change from supine to prone position. Receiver operating characteristic analyses demonstrated that, among the noninvasive methods, the mean ONSD measure had the greatest area under the curve signifying it is the most effective in distinguishing a hypothetical change in ICP between supine and prone positioning (0.86±0.034 [0.79 to 0.92]). A cutoff of 0.43 cm was found to be a best separator of ONSD value between supine and prone with a specificity of 75.0 and a sensitivity of 86.7. Noninvasive ICP estimation may be useful in patients at risk of developing intracranial hypertension who require prone positioning.

  18. Differential diagnosis of benign and malignant breast masses using diffusion-weighted magnetic resonance imaging.

    PubMed

    Min, Qinghua; Shao, Kangwei; Zhai, Lulan; Liu, Wei; Zhu, Caisong; Yuan, Lixin; Yang, Jun

    2015-02-07

    Diffusion-weighted magnetic resonance imaging (DW-MRI) is different from conventional diagnostic methods and has the potential to delineate the microscopic anatomy of a target tissue or organ. The purpose of our study was to evaluate the value of DW-MRI in the diagnosis of benign and malignant breast masses, which would help the clinical surgeon to decide the scope and pattern of operation. A total of 52 female patients with palpable solid breast masses received breast MRI scans using routine sequences, dynamic contrast-enhanced imaging, and diffusion-weighted echo-planar imaging at b values of 400, 600, and 800 s/mm(2), respectively. Two regions of interest (ROIs) were plotted, with a smaller ROI for the highest signal and a larger ROI for the overall lesion. Apparent diffusion coefficient (ADC) values were calculated at three different b values for all detectable lesions and from two different ROIs. The sensitivity, specificity, positive predictive value, and positive likelihood ratio of DW-MRI were determined for comparison with histological results. A total of 49 (49/52, 94.2%) lesions were detected using DW-MRI, including 20 benign lesions (two lesions detected in the same patient) and 29 malignant lesions. Benign lesion had a higher mean ADC value than their malignant counterparts, regardless of b value. According to the receiver operating characteristic (ROC) curve, the smaller-range ROI was more effective in differentiation between benign and malignant lesions. The area under the ROC curve was the largest at a b value of 800 s/mm(2). With a threshold ADC value at 1.23 × 10(-3) mm(2)/s, DW-MRI achieved a sensitivity of 82.8%, specificity of 90.0%, positive predictive value of 92.3%, and positive likelihood ratio of 8.3 for differentiating benign and malignant lesions. DW-MRI is an accurate diagnostic tool for differentiation between benign and malignant breast lesions, with an optimal b value of 800 s/mm(2). A smaller-range ROI focusing on the highest signal has a better differential value.

  19. Branchial cleft anomalies: accuracy of pre-operative diagnosis, clinical presentation and management.

    PubMed

    Guldfred, L-A; Philipsen, B B; Siim, C

    2012-06-01

    To examine the accuracy of the pre-operative diagnosis of branchial cleft anomalies, and also to describe their occurrence, clinical presentation and management. Retrospective review of the records of patients diagnosed with a branchial cleft anomaly between 1997 and 2006. One hundred and twenty-six patients were included. Pre-operative diagnosis had a positive predictive value of 0.856 (95 per cent confidence interval, 0.771-0.918) and a sensitivity of 0.944 (95 per cent confidence interval, 0.869-0.979). These patients' demographic data, investigations, findings and management are presented, along with a possible strategy for dealing with solitary cystic masses in the neck. As pre-operative diagnosis has a positive predictive value of 86 per cent, cystic lesions in the neck should be presumed to be carcinomatous until proven otherwise. Branchial fistulae and sinuses seem to be a disease of childhood, while branchial cysts occur mainly in adults. Branchial cleft anomalies are equally frequent in men and women, and equally distributed on the left and right side of the neck.

  20. Method of improving a digital image

    NASA Technical Reports Server (NTRS)

    Jobson, Daniel J. (Inventor); Woodell, Glenn A. (Inventor); Rahman, Zia-ur (Inventor)

    1999-01-01

    A method of improving a digital image is provided. The image is initially represented by digital data indexed to represent positions on a display. The digital data is indicative of an intensity value I.sub.i (x,y) for each position (x,y) in each i-th spectral band. The intensity value for each position in each i-th spectral band is adjusted to generate an adjusted intensity value for each position in each i-th spectral band in accordance with ##EQU1## where S is the number of unique spectral bands included in said digital data, W.sub.n is a weighting factor and * denotes the convolution operator. Each surround function F.sub.n (x,y) is uniquely scaled to improve an aspect of the digital image, e.g., dynamic range compression, color constancy, and lightness rendition. The adjusted intensity value for each position in each i-th spectral band is filtered with a common function and then presented to a display device. For color images, a novel color restoration step is added to give the image true-to-life color that closely matches human observation.

  1. Relationship Between Operating Room Teamwork, Contextual Factors, and Safety Checklist Performance.

    PubMed

    Singer, Sara J; Molina, George; Li, Zhonghe; Jiang, Wei; Nurudeen, Suliat; Kite, Julia G; Edmondson, Lizabeth; Foster, Richard; Haynes, Alex B; Berry, William R

    2016-10-01

    Studies show that using surgical safety checklists (SSCs) reduces complications. Many believe SSCs accomplish this by enhancing teamwork, but evidence is limited. Our study sought to relate teamwork to checklist performance, understand how they relate, and determine conditions that affect this relationship. Using 2 validated tools for observing and coaching operating room teams, we evaluated the association between checklist performance with surgeon buy-in and 4 domains of surgical teamwork: clinical leadership, communication, coordination, and respect. Hospital staff in 10 South Carolina hospitals observed 207 procedures between April 2011 and January 2013. We calculated levels of checklist performance, buy-in, and measures of teamwork, and evaluated their relationship, controlling for patient and case characteristics. Few teams completed most or all SSC items. Teams more often completed items considered procedural "checks" than conversation "prompts." Surgeon buy-in, clinical leadership, communication, a summary measure of teamwork overall, and observers' teamwork ratings positively related to overall checklist completion (multivariable model estimates from 0.04, p < 0.05 for communication to 0.17, p < 0.01 for surgeon buy-in). All measures of teamwork and surgeon buy-in related positively to completing more conversation prompts; none related significantly to procedural checks (estimates from 0.10, p < 0.01 for communication to 0.27, p < 0.001 for surgeon buy-in). Patient age was significantly associated with completing the checklist and prompts (p < 0.05); only case duration was positively associated with performing more checks (p < 0.10). Surgeon buy-in and surgical teamwork characterized by shared clinical leadership, open communication, active coordination, and mutual respect were critical in prompting case-related conversations, but not in completing procedural checks. Findings highlight the importance of surgeon engagement and high-quality, consistent teamwork for promoting checklist use and ensuring a safe surgical environment. Copyright © 2016 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Performance study of the application of Artificial Neural Networks to the completion and prediction of data retrieved by underwater sensors.

    PubMed

    Baladrón, Carlos; Aguiar, Javier M; Calavia, Lorena; Carro, Belén; Sánchez-Esguevillas, Antonio; Hernández, Luis

    2012-01-01

    This paper presents a proposal for an Artificial Neural Network (ANN)-based architecture for completion and prediction of data retrieved by underwater sensors. Due to the specific conditions under which these sensors operate, it is not uncommon for them to fail, and maintenance operations are difficult and costly. Therefore, completion and prediction of the missing data can greatly improve the quality of the underwater datasets. A performance study using real data is presented to validate the approach, concluding that the proposed architecture is able to provide very low errors. The numbers show as well that the solution is especially suitable for cases where large portions of data are missing, while in situations where the missing values are isolated the improvement over other simple interpolation methods is limited.

  3. 43 CFR 404.39 - What factors will Reclamation consider in evaluating my capability to pay 25 percent or more of...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and depreciation, maintenance and repair); (6) Cash flow from operating activities (positive value... financial obligations; (9) Collateral/equity as appropriate; (10) Cash flows from capital and related financing activities (negative value from principle paid on bonds and interest payments); (11) Net cash flow...

  4. 43 CFR 404.39 - What factors will Reclamation consider in evaluating my capability to pay 25 percent or more of...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... and depreciation, maintenance and repair); (6) Cash flow from operating activities (positive value... financial obligations; (9) Collateral/equity as appropriate; (10) Cash flows from capital and related financing activities (negative value from principle paid on bonds and interest payments); (11) Net cash flow...

  5. 43 CFR 404.39 - What factors will Reclamation consider in evaluating my capability to pay 25 percent or more of...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... and depreciation, maintenance and repair); (6) Cash flow from operating activities (positive value... financial obligations; (9) Collateral/equity as appropriate; (10) Cash flows from capital and related financing activities (negative value from principle paid on bonds and interest payments); (11) Net cash flow...

  6. 43 CFR 404.39 - What factors will Reclamation consider in evaluating my capability to pay 25 percent or more of...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and depreciation, maintenance and repair); (6) Cash flow from operating activities (positive value... financial obligations; (9) Collateral/equity as appropriate; (10) Cash flows from capital and related financing activities (negative value from principle paid on bonds and interest payments); (11) Net cash flow...

  7. Recalculation of regional and detailed gravity database from Slovak Republic and qualitative interpretation of new generation Bouguer anomaly map

    NASA Astrophysics Data System (ADS)

    Pasteka, Roman; Zahorec, Pavol; Mikuska, Jan; Szalaiova, Viktoria; Papco, Juraj; Krajnak, Martin; Kusnirak, David; Panisova, Jaroslava; Vajda, Peter; Bielik, Miroslav

    2014-05-01

    In this contribution results of the running project "Bouguer anomalies of new generation and the gravimetrical model of Western Carpathians (APVV-0194-10)" are presented. The existing homogenized regional database (212478 points) was enlarged by approximately 107 500 archive detailed gravity measurements. These added gravity values were measured since the year 1976 to the present, therefore they need to be unified and reprocessed. The improved positions of more than 8500 measured points were acquired by digitizing of archive maps (we recognized some local errors within particular data sets). Besides the local errors (due to the wrong positions, heights or gravity of measured points) we have found some areas of systematic errors probably due to the gravity measurement or processing errors. Some of them were confirmed and consequently corrected by field measurements within the frame of current project. Special attention is paid to the recalculation of the terrain corrections - we have used a new developed software as well as the latest version of digital terrain model of Slovakia DMR-3. Main improvement of the new terrain corrections evaluation algorithm is the possibility to calculate it in the real gravimeter position and involving of 3D polyhedral bodies approximation (accepting the spherical approximation of Earth's curvature). We have realized several tests by means of the introduction of non-standard distant relief effects introduction. A new complete Bouguer anomalies map was constructed and transformed by means of higher derivatives operators (tilt derivatives, TDX, theta-derivatives and the new TDXAS transformation), using the regularization approach. A new interesting regional lineament of probably neotectonic character was recognized in the new map of complete Bouguer anomalies and it was confirmed also by realized in-situ field measurements.

  8. Value of amino-terminal pro B-natriuretic peptide in diagnosing Kawasaki disease.

    PubMed

    McNeal-Davidson, Ariane; Fournier, Anne; Spigelblatt, Linda; Saint-Cyr, Claire; Mir, Thomas S; Nir, Amiram; Dallaire, Frédéric; Cousineau, Jocelyne; Delvin, Edgard; Dahdah, Nagib

    2012-10-01

    The aim of the present study was to investigate the diagnostic value of the N-terminal B-type natriuretic peptide (NT-proBNP) in acute Kawasaki disease (KD) given that the clinical criteria and the current basic laboratory tests lack the necessary specificity for accurate diagnosis. Basic biological tests and serum NT-proBNP levels obtained from acute KD patients were compared to that of febrile controls. NT-proBNP was considered abnormal based on the following definitions: above a cut-off determined on receiver operator characteristic (ROC) analysis, above the upper limit for age, or above 2 SD calculated from healthy children. Analyses were also performed for KD cases with complete or incomplete criteria combined and separately. There were 81 patients and 49 controls aged 3.60 ± 2.77 versus 4.25 ± 3.88 years (P= 0.69). ROC analysis yielded significant area under the curve for NT-proBNP. The sensitivity, specificity, positive and negative predictive values were 70.4-88.9%, 69.4-91.8%, 82.8-93.4%, and 65.2-79.1%. The odds ratios based on NT-proBNP definitions varied between 18.13 (95% confidence interval [CI]: 7.21-45.57), 20.82 (95%CI: 8.18-53.0), and 26.71 (95%CI: 8.64-82.57; P < 0.001). Results were reproducible for cases with complete or incomplete criteria separately. NT-proBNP is a reliable marker for the diagnosis of KD. Prospective clinical studies with emphasis on NT-proBNP in a diagnostic algorithm are needed. © 2012 The Authors. Pediatrics International © 2012 Japan Pediatric Society.

  9. Beam position monitoring system at CESR

    NASA Astrophysics Data System (ADS)

    Billing, M. G.; Bergan, W. F.; Forster, M. J.; Meller, R. E.; Rendina, M. C.; Rider, N. T.; Sagan, D. C.; Shanks, J.; Sikora, J. P.; Stedinger, M. G.; Strohman, C. R.; Palmer, M. A.; Holtzapple, R. L.

    2017-09-01

    The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the specific topics that were targeted for the initial phase of operation of the storage ring in this mode, labeled CESRTA (CESR as a Test Accelerator), included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CESRTA occurred over a several year period and is described elsewhere. As a part of this conversion the CESR beam position monitoring (CBPM) system was completely upgraded to provide the needed instrumental capabilities for these studies. This paper describes the new CBPM system hardware, its function and representative measurements performed by the upgraded system.

  10. [Treatment outcomes for tuberculosis patients in FBIH during 1998-2003].

    PubMed

    Ustamujić, Aida; Dizdarević, Zehra; Zutić, Hasan

    2007-01-01

    To evaluate treatment outcome data for all new pulmonary sputum smear positive cases and treatment outcome data for all new pulmonary culture positive cases. To evaluate re-treatment outcome data for all retreated pulmonary sputum smear positive Tb cases and re-treatment outcome data for all retreated pulmonary culture positive TB cases,in FB&H, in the period 1998-2003. Achieving WHO aims of 85% success on new found TB cases. Retrospective cohort analysis for new pulmonary smear positive cases, new pulmonary culture positive cases. Retrospective cohort analysis for retreated pulmonary smear-positive cases; retreated pulmonary culture positive cases, registered in FB&H in the period 1998-2003. A recording and reporting system used standardized registers according to WHO. Results are presented in four tables and four graphs. Middle rate of success (cured or completed treatment) was 84%, middle value of failed (5%), defaulted (5%) and transferred (2%). Results of success in newfound TB cases are achiived according to WHO aims (85-90,7%). Success NTP in control of TB is concern on ability to hold high rate of cured or completed treatment.

  11. 40 CFR Table 2 to Subpart Uuuu of... - Operating Limits

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... values established during the compliance demonstration. 7. carbon absorber maintain the regeneration frequency, total regeneration adsorber stream mass or volumetric flow during carbon bed regeneration, and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s...

  12. 40 CFR Table 2 to Subpart Uuuu of... - Operating Limits

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... values established during the compliance demonstration. 7. carbon absorber maintain the regeneration frequency, total regeneration adsorber stream mass or volumetric flow during carbon bed regeneration, and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s...

  13. 40 CFR Table 2 to Subpart Uuuu of... - Operating Limits

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... values established during the compliance demonstration. 7. carbon absorber maintain the regeneration frequency, total regeneration adsorber stream mass or volumetric flow during carbon bed regeneration, and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s...

  14. Is it necessary to remove the seminal vesicles completely at radical prostatectomy? decision curve analysis of European Society of Urologic Oncology criteria.

    PubMed

    Secin, Fernando P; Bianco, Fernando J; Cronin, Angel; Eastham, James A; Scardino, Peter T; Guillonneau, Bertrand; Vickers, Andrew J

    2009-02-01

    A publication on behalf of the European Society of Urological Oncology questioned the need for removing the seminal vesicles during radical prostatectomy in patients with prostate specific antigen less than 10 ng/ml except when biopsy Gleason score is greater than 6 or there are greater than 50% positive biopsy cores. We applied the European Society of Urological Oncology algorithm to an independent data set to determine its predictive value. Data on 1,406 men who underwent radical prostatectomy and seminal vesicle removal between 1998 and 2004 were analyzed. Patients with and without seminal vesicle invasion were classified as positive or negative according to the European Society of Urological Oncology algorithm. Of 90 cases with seminal vesicle invasion 81 (6.4%) were positive for 90% sensitivity, while 656 of 1,316 without seminal vesicle invasion were negative for 50% specificity. The negative predictive value was 98.6%. In decision analytic terms if the loss in health when seminal vesicles are invaded and not completely removed is considered at least 75 times greater than when removing them unnecessarily, the algorithm proposed by the European Society of Urological Oncology should not be used. Whether to use the European Society of Urological Oncology algorithm depends not only on its accuracy, but also on the relative clinical consequences of false-positive and false-negative results. Our threshold of 75 is an intermediate value that is difficult to interpret, given uncertainties about the benefit of seminal vesicle sparing and harm associated with untreated seminal vesicle invasion. We recommend more formal decision analysis to determine the clinical value of the European Society of Urological Oncology algorithm.

  15. Treatment of Periodontal Disease with an Octenidine-based Antiseptic in HIV-positive Patients.

    PubMed

    Gušić, I; Medić, D; Radovanović Kanjuh, M; Ðurić, M; Brkić, S; Turkulov, V; Predin, T; Mirnić, J

    2016-05-01

    To evaluate the effects of a periodontal therapy with subsequent application of an octenidine (OCT)-based antiseptic in HIV-positive patients receiving highly active antiretroviral therapy. HIV-positive patients with a clinically diagnosed periodontal disease were randomly divided into two groups (n = 30/group). Both groups initially received a periodontal therapy. Patients in the OCT group additionally used an OCT-based mouthwash. Subgingival plaque samples and periodontal indices were analysed prior to treatment onset as well as one and 3 months post-treatment. Periodontal therapy has resulted in a significant decrease in the values of all periodontal indices one and 3 months following the therapy completion (P = 0.000). The effects of the two applied therapeutic protocols differed significantly in terms of the variation in the PBI (F = 4.617; P = 0.017) and the PD (F = 3.203; P = 0.044) value. In the patients in the OCT group, a more pronounced decrease in the PBI and PD was noted at 1-month follow-up as well as a greater increase in the PD value 3 months upon treatment completion. In the OCT group, no more atypical microorganisms were detectable 1 month post-treatment, while in the control group they were found in 34.5% of patients. The periodontal therapy bears good results in HIV-positive patients. Additional administration of OCT contributes to the significant decline in the PBI and DS values and eliminates atypical microorganisms within 1 month post-treatment. However, more favourable results were not noted in the OCT group at the 3-month assessment. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Organizing OPNAV (1970-2009). Revision 2

    DTIC Science & Technology

    2010-01-01

    Naval Operations, (N4) Deputy Chief of Naval Operations, (N8) Director, Navy Staff Commander, Fleet Forces Command President , Naval War College... President , Naval Postgraduate School Subj: STUDY "ORGANIZING OPNAV, 1970-2009" Encl: (1) copy "Organizing OPNAV, 1970-2009" 1. The Naval History and...office. Completion of this study is timed to coincide with the upcoming 100th anniversary of the 1915 creation of the position of CNO by President

  17. Operation of GRETINA at NSCL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherrill, Bradley; Gade, Alexandra

    This proposal funded the continued operation of the Gamma-ray Energy tracking Array GRETINA as a user device at the National Superconducting Cyclotron Laboratory (NSCL) at Michigan State University. This was a continuation and covered the operation from January 1, 2017 to December 31, 2017. Twenty-three experiments were completed with GRETINA at NSCL. GRETINA was installed at the reaction target position of the high-resolution, large-acceptance S800 spectrograph and the program started on October 15, 2017. The campaign capitalized on the opportunities provided by NSCL’s energetic rare isotope beams produced by projectile fragmentation.

  18. Transoral robotic surgery in the seated position: Rethinking our operative approach.

    PubMed

    Moore, Eric J; Van Abel, Kathryn M; Olsen, Kerry D

    2017-01-01

    Transoral surgery (TOS) is commonly performed in a supine patient with an oral retractor. Paradoxically, this strategy can create difficulty with visualizing and accessing pathology at the base of tongue, inferior pharynx, and larynx. We investigate the feasibility of TOS with the patient in the seated position. Pilot study. TOS utilizing the da Vinci Robotic Surgical Xi and Si systems (Intuitive Surgical, Sunnyvale, CA) was performed on a fresh cadaver placed in both the traditional supine position and the seated position. Transoral robotic surgery (TORS) in the seated position was then performed on two patients for a supraglottic laryngectomy and a hypopharyngeal carcinoma resection. Visualization of the entire upper aerodigestive tract was possible in the cadaver and two patients in the seated position. The Si was superior for docking, instrumentation, and assistant access. The minimum operating table height is critical for successful access. Advantages of this position included increased posterior airway/operative space by approximately 2 cm, ability to manipulate the surgical field (nonrigid retraction), and improved visualization. Surgical procedures were completed in comparable times compared with standard TORS procedures. There were no complications related to seated TORS. TORS in the seated position was both safe and effective in this pilot study. It allows the surgeon to optimally operate in the inferior pharynx and larynx without the limitation of line of site access and visualization. A paradigm shift in patient positioning during TOS may allow improved surgical access and even greater patient candidacy. Further clinical investigation into this technique is warranted. NA Laryngoscope, 127:122-126, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  19. Training and retaining community pharmacy leaders: Career pathways after completing a PGY1 community pharmacy residency affiliated with a large supermarket chain.

    PubMed

    Hohmeier, Kenneth C; Borja-Hart, Nancy; Cooper, Maureen; Kirby, James; Fisher, Cindy

    To determine pharmacist career paths and resident perceptions after completion of a PGY1 community pharmacy residency with a national supermarket pharmacy chain. Cross-sectional nationwide survey. Overall, 65% (n = 24) of residents who responded accepted a position with Kroger immediately after graduation. When asked about the degree of value the residency had on obtaining the resident's ideal position, 29 (76%) reported that it was "very valuable" and the remaining 9 (24%) reported that it was "somewhat valuable." Positions that these pharmacists held immediately after residency completion were: clinical pharmacist (clinical coordinators, patient care specialists, or patient care managers; 54%), staff pharmacist (21%), split/mixed (mixed clinical and staffing components; 21%), and pharmacy manager (4%). Residency trained pharmacists were retained by the pharmacy chain where they practiced, and the majority of those pharmacists held split or full-time clinical pharmacist roles within the chain supermarket pharmacy. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  20. Build your own low-cost seismic/bathymetric recorder annotator

    USGS Publications Warehouse

    Robinson, W.

    1994-01-01

    An inexpensive programmable annotator, completely compatible with at least three models of widely used graphic recorders (Raytheon LSR-1811, Raytheon LSR-1807 M, and EDO 550) has been developed to automatically write event marks and print up to sixteen numbers on the paper record. Event mark and character printout intervals, character height and character position are all selectable with front panel switches. Operation is completely compatible with recorders running in either continuous or start-stop mode. ?? 1994.

  1. Design and Operation of the Synthesis Gas Generator System for Reformed Propane and Glycerin Combustion

    NASA Astrophysics Data System (ADS)

    Pickett, Derek Kyle

    Due to an increased interest in sustainable energy, biodiesel has become much more widely used in the last several years. Glycerin, one major waste component in biodiesel production, can be converted into a hydrogen rich synthesis gas to be used in an engine generator to recover energy from the biodiesel production process. This thesis contains information detailing the production, testing, and analysis of a unique synthesis generator rig at the University of Kansas. Chapter 2 gives a complete background of all major components, as well as how they are operated. In addition to component descriptions, methods for operating the system on pure propane, reformed propane, reformed glycerin along with the methodology of data acquisition is described. This chapter will serve as a complete operating manual for future students to continue research on the project. Chapter 3 details the literature review that was completed to better understand fuel reforming of propane and glycerin. This chapter also describes the numerical model produced to estimate the species produced during reformation activities. The model was applied to propane reformation in a proof of concept and calibration test before moving to glycerin reformation and its subsequent combustion. Chapter 4 first describes the efforts to apply the numerical model to glycerin using the calibration tools from propane reformation. It then discusses catalytic material preparation and glycerin reformation tests. Gas chromatography analysis of the reformer effluent was completed to compare to theoretical values from the numerical model. Finally, combustion of reformed glycerin was completed for power generation. Tests were completed to compare emissions from syngas combustion and propane combustion.

  2. Emergency deployable core catcher

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosewell, M.P.

    An emergency melt down core catcher apparatus for a nuclear reactor having a retrofitable eutectic solute holding vessel connected to a core containment vessel with particle transferring fluid and particles or granules of solid eutectic solute materials contained therein and transferable by automatically operated valve means to transport and position the solid eutectic solute material in a position below the core to catch and react with any partial or complete melt down of the fuel core.

  3. [Diagnostic value of a predictive model for complete ruptures of the rotator cuff associated to subacromial impingement].

    PubMed

    Águila-Ledesma, I R; Córdova-Fonseca, J L; Medina-Pontaza, O; Núñez-Gómez, D A; Calvache-García, C; Pérez-Atanasio, J M; Torres-González, R

    2017-01-01

    Pathology related to the rotator cuff remains among the most prevalent musculoskeletal diseases. There is an increasing need for imaging studies (MRI, US, arthroscopy) to test the diagnostic performance of the medical history and physical examination. To prove the diagnostic value of a clinical-radiographic predictive model to find complete ruptures of the rotator cuff. Descriptive, observational, prospective, transversal and analytical study. Fifty-five patients with preoperative shoulder pain were evaluated with 13 predictive variables: age > 50 years, nocturnal pain, muscle weakness, clinical signs of Neer, Hawkins, Jobe, external rotation lag (ERLS), belly-press, bear hug, and lift-off, radiographic measurement of subacromial space, acromial index and critical shoulder angle. Sensitivity, specificity, and positive and negative predictive values were measured in each variable, comparing the results of each one against the postoperative findings. Of the 55 patients evaluated, 42 had a complete rupture of the rotator cuff in the postoperative period. The eight variables with a higher diagnostic value were selected and a ROC curve was performed, providing an area under the curve of 0.88. This predictive model uses eight variables (age > 50 years, nocturnal pain, muscle weakness, Jobe, Hawkins, ERLS, subacromial space ≤ 6 mm, and critical shoulder angle > 35°), which together add the predictive value of 0.88 (AUC) to diagnose complete ruptures of the supraspinatus tendon.

  4. Routine intraoperative completion angiography after coronary artery bypass grafting and 1-stop hybrid revascularization results from a fully integrated hybrid catheterization laboratory/operating room.

    PubMed

    Zhao, David X; Leacche, Marzia; Balaguer, Jorge M; Boudoulas, Konstantinos D; Damp, Julie A; Greelish, James P; Byrne, John G; Ahmad, Rashid M; Ball, Stephen K; Cleator, John H; Deegan, Robert J; Eagle, Susan S; Fong, Pete P; Fredi, Joseph L; Hoff, Steven J; Jennings, Henry S; McPherson, John A; Piana, Robert N; Pretorius, Mias; Robbins, Mark A; Slosky, David A; Thompson, Annemarie

    2009-01-20

    This study sought to report our experience with a routine completion angiogram after coronary artery bypass surgery (CABG) and simultaneous (1-stop) percutaneous coronary intervention (PCI) at the time of CABG performed in the hybrid catheterization laboratory/operating room. The value of a routine completion angiogram after CABG and 1-stop hybrid CABG/PCI remains unresolved. Between April 2005 and July 2007, 366 consecutive patients underwent CABG surgery, with (n = 112) or without (n = 254) concomitant 1-stop PCI (hybrid), all with completion angiography before chest closure. Among the 112 1-stop hybrid CABG/PCI patients, 67 (60%) underwent a planned hybrid procedure based on pre-operative assessment, whereas 45 (40%) underwent open-chest PCI (unplanned hybrid) based on intraoperative findings. Among the 796 CABG grafts (345 left internal mammary artery, 12 right internal mammary artery/radial, and 439 veins), 97 (12%) angiographic defects were identified. Defects were repaired with either a minor adjustment of the graft (n = 22, 2.8%), with intraoperative open-chest PCI (unplanned hybrid, n = 48, 6%) or with traditional surgical revision (n = 27, 3.4%). Hybrid patients had clinical outcomes similar to standard CABG patients. Routine completion angiography detected 12% of grafts with important angiographic defects. One-stop hybrid coronary revascularization is reasonable, safe, and feasible. Combining the tools of the catheterization laboratory and operating room greatly enhances the options available to the surgeon and cardiologist for patients with complex coronary artery disease.

  5. An effective PSO-based memetic algorithm for flow shop scheduling.

    PubMed

    Liu, Bo; Wang, Ling; Jin, Yi-Hui

    2007-02-01

    This paper proposes an effective particle swarm optimization (PSO)-based memetic algorithm (MA) for the permutation flow shop scheduling problem (PFSSP) with the objective to minimize the maximum completion time, which is a typical non-deterministic polynomial-time (NP) hard combinatorial optimization problem. In the proposed PSO-based MA (PSOMA), both PSO-based searching operators and some special local searching operators are designed to balance the exploration and exploitation abilities. In particular, the PSOMA applies the evolutionary searching mechanism of PSO, which is characterized by individual improvement, population cooperation, and competition to effectively perform exploration. On the other hand, the PSOMA utilizes several adaptive local searches to perform exploitation. First, to make PSO suitable for solving PFSSP, a ranked-order value rule based on random key representation is presented to convert the continuous position values of particles to job permutations. Second, to generate an initial swarm with certain quality and diversity, the famous Nawaz-Enscore-Ham (NEH) heuristic is incorporated into the initialization of population. Third, to balance the exploration and exploitation abilities, after the standard PSO-based searching operation, a new local search technique named NEH_1 insertion is probabilistically applied to some good particles selected by using a roulette wheel mechanism with a specified probability. Fourth, to enrich the searching behaviors and to avoid premature convergence, a simulated annealing (SA)-based local search with multiple different neighborhoods is designed and incorporated into the PSOMA. Meanwhile, an effective adaptive meta-Lamarckian learning strategy is employed to decide which neighborhood to be used in SA-based local search. Finally, to further enhance the exploitation ability, a pairwise-based local search is applied after the SA-based search. Simulation results based on benchmarks demonstrate the effectiveness of the PSOMA. Additionally, the effects of some parameters on optimization performances are also discussed.

  6. 33 CFR 157.12f - Workshop functional test requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12f Workshop functional test requirements... the specific design of equipment. A completed workshop certificate including the delivery test... several ppm values on all measurement scales when operated on an oil appropriate for the application of...

  7. 33 CFR 157.12f - Workshop functional test requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12f Workshop functional test requirements... the specific design of equipment. A completed workshop certificate including the delivery test... several ppm values on all measurement scales when operated on an oil appropriate for the application of...

  8. 23 CFR 627.5 - Applicable projects.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 23 Highways 1 2013-04-01 2013-04-01 false Applicable projects. 627.5 Section 627.5 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND TRAFFIC OPERATIONS VALUE ENGINEERING § 627.5 Applicable projects. (a) A VE analysis shall be conducted prior to the completion of final...

  9. 23 CFR 627.5 - Applicable projects.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 23 Highways 1 2014-04-01 2014-04-01 false Applicable projects. 627.5 Section 627.5 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND TRAFFIC OPERATIONS VALUE ENGINEERING § 627.5 Applicable projects. (a) A VE analysis shall be conducted prior to the completion of final...

  10. Alternative Fuels Data Center: Maps and Data

    Science.gov Websites

    vehicles with unidentified fuel types. Data consists of registered vehicles in operation in the United fuel types with small populations, such as methanol and hydrogen vehicles. See relative vehicle completed a conversion. "undefined" values are vehicles with unidentified fuel types. Data

  11. On set-valued functionals: Multivariate risk measures and Aumann integrals

    NASA Astrophysics Data System (ADS)

    Ararat, Cagin

    In this dissertation, multivariate risk measures for random vectors and Aumann integrals of set-valued functions are studied. Both are set-valued functionals with values in a complete lattice of subsets of Rm. Multivariate risk measures are considered in a general d-asset financial market with trading opportunities in discrete time. Specifically, the following features of the market are incorporated in the evaluation of multivariate risk: convex transaction costs modeled by solvency regions, intermediate trading constraints modeled by convex random sets, and the requirement of liquidation into the first m ≤ d of the assets. It is assumed that the investor has a "pure" multivariate risk measure R on the space of m-dimensional random vectors which represents her risk attitude towards the assets but does not take into account the frictions of the market. Then, the investor with a d-dimensional position minimizes the set-valued functional R over all m-dimensional positions that she can reach by trading in the market subject to the frictions described above. The resulting functional Rmar on the space of d-dimensional random vectors is another multivariate risk measure, called the market-extension of R. A dual representation for R mar that decomposes the effects of R and the frictions of the market is proved. Next, multivariate risk measures are studied in a utility-based framework. It is assumed that the investor has a complete risk preference towards each individual asset, which can be represented by a von Neumann-Morgenstern utility function. Then, an incomplete preference is considered for multivariate positions which is represented by the vector of the individual utility functions. Under this structure, multivariate shortfall and divergence risk measures are defined as the optimal values of set minimization problems. The dual relationship between the two classes of multivariate risk measures is constructed via a recent Lagrange duality for set optimization. In particular, it is shown that a shortfall risk measure can be written as an intersection over a family of divergence risk measures indexed by a scalarization parameter. Examples include the multivariate versions of the entropic risk measure and the average value at risk. In the second part, Aumann integrals of set-valued functions on a measurable space are viewed as set-valued functionals and a Daniell-Stone type characterization theorem is proved for such functionals. More precisely, it is shown that a functional that maps measurable set-valued functions into a certain complete lattice of subsets of Rm can be written as the Aumann integral with respect to a measure if and only if the functional is (1) additive and (2) positively homogeneous, (3) it preserves decreasing limits, (4) it maps halfspace-valued functions to halfspaces, and (5) it maps shifted cone-valued functions to shifted cones. While the first three properties already exist in the classical Daniell-Stone theorem for the Lebesgue integral, the last two properties are peculiar to the set-valued framework and they suffice to complement the first three properties to identify a set-valued functional as the Aumann integral with respect to a measure.

  12. Effects of complete water fasting and regeneration diet on kidney function, oxidative stress and antioxidants.

    PubMed

    Mojto, V; Gvozdjakova, A; Kucharska, J; Rausova, Z; Vancova, O; Valuch, J

    2018-01-01

    The aim of the study was to observe the influence of 11-days complete water fasting (WF) and regeneration diet (RD) on renal function, body weight, blood pressure and oxidative stress. Therapeutic WF is considered a healing method. Ten volunteers drank only water for 11 days, followed by RD for the next 11 days. Data on body weight, blood pressure, kidney functions, antioxidants, lipid peroxidation, cholesterols, triacylglycerols and selected biochemical parameters were obtained. WF increased uric acid and creatinine and decreased glomerular filtration rate. After RD, the parameters were comparable to baseline values. Urea was not affected. Lipid peroxidation (TBARS) decreased and maintained stable after RD. Fasting decreased α-tocopherol and increased γ-tocopherol, no significant changes were found after RD. Coenzyme Q10 decreased after RD. HDL-cholesterol decreased in WF. Total- and LDL-cholesterol decreased after RD. Other biochemical parameters were within the range of reference values. The effect of the complete fasting on kidney function was manifested by hyperuricemia. Renal function was slightly decreased, however maintained within the reference values. After RD, it returned to baseline values. The positive effect of the complete water fasting was in the reduction of oxidative stress, body weight and blood pressure (Tab. 3, Ref. 25).

  13. Positioning the Learning Asset Portfolio as a Key Component in an Organization's Enterprise Risk Management Strategy

    ERIC Educational Resources Information Center

    McAliney, Peter J.

    2009-01-01

    This article presents a process for valuing a portfolio of learning assets used by line executives across industries to value traditional business assets. Embedded within the context of enterprise risk management, this strategic asset allocation process is presented step by step, providing readers the operational considerations to implement this…

  14. Influence of the vibro-acoustic sensor position on cavitation detection in a Kaplan turbine

    NASA Astrophysics Data System (ADS)

    Schmidt, H.; Kirschner, O.; Riedelbauch, S.; Necker, J.; Kopf, E.; Rieg, M.; Arantes, G.; Wessiak, M.; Mayrhuber, J.

    2014-03-01

    Hydraulic turbines can be operated close to the limits of the operating range to meet the demand of the grid. When operated close to the limits, the risk increases that cavitation phenomena may occur at the runner and / or at the guide vanes of the turbine. Cavitation in a hydraulic turbine can cause material erosion on the runner and other turbine parts and reduce the durability of the machine leading to required outage time and related repair costs. Therefore it is important to get reliable information about the appearance of cavitation during prototype operation. In this experimental investigation the high frequency acoustic emissions and vibrations were measured at 20 operating points with different cavitation behaviour at different positions in a large prototype Kaplan turbine. The main goal was a comparison of the measured signals at different sensor positions to identify the sensitivity of the location for cavitation detection. The measured signals were analysed statistically and specific values were derived. Based on the measured signals, it is possible to confirm the cavitation limit of the examined turbine. The result of the investigation shows that the position of the sensors has a significant influence on the detection of cavitation.

  15. Sign changes in sums of the Liouville function

    NASA Astrophysics Data System (ADS)

    Borwein, Peter; Ferguson, Ron; Mossinghoff, Michael J.

    2008-09-01

    The Liouville function λ(n) is the completely multiplicative function whose value is -1 at each prime. We develop some algorithms for computing the sum T(n)Dsum_{kD1}^n λ(k)/k , and use these methods to determine the smallest positive integer n where T(n)<0 . This answers a question originating in some work of Turan, who linked the behavior of T(n) to questions about the Riemann zeta function. We also study the problem of evaluating Polya's sum L(n)Dsum_{kD1}^nλ(k) , and we determine some new local extrema for this function, including some new positive values.

  16. Happiness increases verbal and spatial working memory capacity where sadness does not: Emotion, working memory and executive control.

    PubMed

    Storbeck, Justin; Maswood, Raeya

    2016-08-01

    The effects of emotion on working memory and executive control are often studied in isolation. Positive mood enhances verbal and impairs spatial working memory, whereas negative mood enhances spatial and impairs verbal working memory. Moreover, positive mood enhances executive control, whereas negative mood has little influence. We examined how emotion influences verbal and spatial working memory capacity, which requires executive control to coordinate between holding information in working memory and completing a secondary task. We predicted that positive mood would improve both verbal and spatial working memory capacity because of its influence on executive control. Positive, negative and neutral moods were induced followed by completing a verbal (Experiment 1) or spatial (Experiment 2) working memory operation span task to assess working memory capacity. Positive mood enhanced working memory capacity irrespective of the working memory domain, whereas negative mood had no influence on performance. Thus, positive mood was more successful holding information in working memory while processing task-irrelevant information, suggesting that the influence mood has on executive control supersedes the independent effects mood has on domain-specific working memory.

  17. Equivalence of qubit-environment entanglement and discord generation via pure dephasing interactions and the resulting consequences

    NASA Astrophysics Data System (ADS)

    Roszak, Katarzyna; Cywiński, Łukasz

    2018-01-01

    We find that when a qubit initialized in a pure state experiences pure dephasing due to interaction with an environment, separable qubit-environment states generated during the evolution also have zero quantum discord with respect to the environment. What follows is that the set of separable states which can be reached during the evolution has zero volume, and hence, such effects as sudden death of qubit-environment entanglement are very unlikely. In the case of the discord with respect to the qubit, a vast majority of qubit-environment separable states is discordant, but in specific situations zero-discord states are possible. This is conceptually important since there is a connection between the discordance with respect to a given subsystem and the possibility of describing the evolution of this subsystem using completely positive maps. Finally, we use the formalism to find an exemplary evolution of an entangled state of two qubits that is completely positive, and occurs solely due to interaction of only one of the qubits with its environment (so one could guess that it corresponds to a local operation, since it is local in a physical sense), but which nevertheless causes the enhancement of entanglement between the qubits. While this simply means that the considered evolution is completely positive, but does not belong to local operations and classical communication, it shows how much caution has to be exercised when identifying evolution channels that belong to that class.

  18. Pre- and post-operative evaluations of eight dogs following right nephrectomy due to Dioctophyma renale.

    PubMed

    Mesquita, L R; Rahal, S C; Faria, L G; Takahira, R K; Rocha, N S; Mamprim, M J; Oliveira, H S

    2014-01-01

    Dioctophyma renale is a large nematode distributed worldwide that may cause progressive and severe destruction of renal parenchyma. The present study aimed to evaluate pre- and post-operatively dogs submitted to right nephrectomy due to D. renale and to assess the histopathological damage of the removed kidney. Eight crossbred dogs, aged from 12 to 48 months that were unilaterally nephrectomized due to the presence of D. renale were evaluated. Physical examination, urinalysis, complete blood count, serum biochemistry, and abdominal ultrasound were performed immediately before and one month after nephrectomy. The nephrectomized right kidneys were submitted to macroscopic and microscopic evaluations. Urinalysis preoperatively detected occult blood in all dogs and D. renale eggs in five cases. Complete blood count showed all parameters within the reference range, except one dog post-operatively. Serum biochemistry performed before and after surgery verified that urea, creatinine and sodium were within the reference range values in all dogs. Other findings varied among the dogs. The length and arterial resistive index mean values of the left kidney were similar pre- and post-operatively. Thus, the inconsiderable change in laboratory findings pre- and post-operatively was attributable to compensation by left kidney function for the removed abnormal right kidney. Right kidney histology revealed chronic nephropathy due to D. renale. Imaging diagnosis should be performed on dogs suspected as carrying the disease or on those from an enzootic area since the laboratory findings are not specific except eggs in the urine.

  19. Control of Smart Building Using Advanced SCADA

    NASA Astrophysics Data System (ADS)

    Samuel, Vivin Thomas

    For complete control of the building, a proper SCADA implementation and the optimization strategy has to be build. For better communication and efficiency a proper channel between the Communication protocol and SCADA has to be designed. This paper concentrate mainly between the communication protocol, and the SCADA implementation, for a better optimization and energy savings is derived to large scale industrial buildings. The communication channel used in order to completely control the building remotely from a distant place. For an efficient result we consider the temperature values and the power ratings of the equipment so that while controlling the equipment, we are setting a threshold values for FDD technique implementation. Building management system became a vital source for any building to maintain it and for safety purpose. Smart buildings, refers to various distinct features, where the complete automation system, office building controls, data center controls. ELC's are used to communicate the load values of the building to the remote server from a far location with the help of an Ethernet communication channel. Based on the demand fluctuation and the peak voltage, the loads operate differently increasing the consumption rate thus results in the increase in the annual consumption bill. In modern days, saving energy and reducing the consumption bill is most essential for any building for a better and long operation. The equipment - monitored regularly and optimization strategy is implemented for cost reduction automation system. Thus results in the reduction of annual cost reduction and load lifetime increase.

  20. Initial conditions for critical Higgs inflation

    NASA Astrophysics Data System (ADS)

    Salvio, Alberto

    2018-05-01

    It has been pointed out that a large non-minimal coupling ξ between the Higgs and the Ricci scalar can source higher derivative operators, which may change the predictions of Higgs inflation. A variant, called critical Higgs inflation, employs the near-criticality of the top mass to introduce an inflection point in the potential and lower drastically the value of ξ. We here study whether critical Higgs inflation can occur even if the pre-inflationary initial conditions do not satisfy the slow-roll behavior (retaining translation and rotation symmetries). A positive answer is found: inflation turns out to be an attractor and therefore no fine-tuning of the initial conditions is necessary. A very large initial Higgs time-derivative (as compared to the potential energy density) is compensated by a moderate increase in the initial field value. These conclusions are reached by solving the exact Higgs equation without using the slow-roll approximation. This also allows us to consistently treat the inflection point, where the standard slow-roll approximation breaks down. Here we make use of an approach that is independent of the UV completion of gravity, by taking initial conditions that always involve sub-planckian energies.

  1. Well-posedness of nonlocal parabolic differential problems with dependent operators.

    PubMed

    Ashyralyev, Allaberen; Hanalyev, Asker

    2014-01-01

    The nonlocal boundary value problem for the parabolic differential equation v'(t) + A(t)v(t) = f(t) (0 ≤ t ≤ T), v(0) = v(λ) + φ, 0 < λ ≤ T in an arbitrary Banach space E with the dependent linear positive operator A(t) is investigated. The well-posedness of this problem is established in Banach spaces C 0 (β,γ) (E α-β ) of all E α-β -valued continuous functions φ(t) on [0, T] satisfying a Hölder condition with a weight (t + τ)(γ). New Schauder type exact estimates in Hölder norms for the solution of two nonlocal boundary value problems for parabolic equations with dependent coefficients are established.

  2. Sonographic evaluation of the fetal spine position and success rate of manual rotation of the fetus in occiput posterior position: A randomized controlled trial.

    PubMed

    Masturzo, Bianca; Farina, Antonio; Attamante, Lorenza; Piazzese, Annalisa; Rolfo, Alessandro; Gaglioti, Pietro; Todros, Tullia

    2017-10-01

    To evaluate whether sonographic (US) diagnosis of the fetal spine position could increase the success rate of manual rotation of the fetal occiput (MRFO) in second-stage arrest in persistent occiput posterior position (OPP). In this randomized controlled parallel single-center trial, 58 nulliparous in second-stage arrest of labor with fetus in cephalic presentation and OPP diagnosed by US were randomly assigned to group A where the fetal spine position was not known by the operator or to group B where the operator knew it. The main outcome was the success of MRFO in the two groups. Secondary outcomes were perineal injuries, blood loss, duration of expulsive period, and neonatal APGAR at 5 minutes. A priori knowledge of the spine position improves the success of the MRFO (41.4% group A versus 82.8% group B, p value < 0.001), the percentage of spontaneous deliveries (27.6% group A versus 69% group B, p value = 0.01), and maternal outcome (intact perineum and blood loss). No differences were detected on the neonatal side. MRFO is a safe and useful procedure that should be performed in second-stage arrest in OPP. A better performance was observed when supported by the US knowledge of the spine position. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:472-476, 2017. © 2017 Wiley Periodicals, Inc.

  3. How valuable is P-wave dispersion in the determination of carboxyhemoglobin levels?

    PubMed

    Sener, M T; Anci, Y; Kalkan, K; Kir, M Z; Emet, M

    2014-05-01

    To determine whether or not wave/interval dispersions in electrocardiography (ECG) are increased, and to define whether wave and interval dispersions are correlated with carboxyhemoglobin (COHb) levels. ECG, complete blood count, and biochemical parameters were taken from 87 patients with carbon monoxide (CO) poisoning as well as 90 control patients with similar age, gender, and body mass index distribution. COHb levels were recorded in CO-poisoning patients. The COHb levels and the relationships with ECG parameters were studied. Pmax, Pmin, Pd, PRmax, PRmin, PRd, QTmax, QTmin, QTd, cQTmax, cQTmin, cQTd, Tmax, Tmin, and Td in ECG were higher in intoxicated patients than the control group (p < 0.05 for all). Pearson's correlation analyses showed moderately significant positive correlations between COHb level and Pmax (r = 0.224; p = 0.037) and Pd (r = 0.222; p = 0.039). The receiver-operator characteristic (ROC) curve showed that a Pd value of 38 ms determined by ECG separates patients with a COHb ≥ 20% with area under the ROC curve of 0.78 (95%CI = 0.71-0.83), a sensitivity of 67.9% (95%CI = 59.4-75.6), a specificity of 95% (95%CI = 83.0-99.2], a positive predictive value of 97.9% (95%CI = 92.5-99.7), and a negative predictive value of 46.3% (95%CI = 35.3-57.7.) A significant increase in wave/interval dispersions in the ECG of CO-poisoning patients compared with controls may show that not only a part is affected but both atrium and the ventricles as a whole are affected by hypoxic ischemia. When COHb levels of the patients are unavailable, P dispersion on ECG may show CO poisoning level of the patient.

  4. Enough positive rate of paraspinal mapping and diffusion tensor imaging with levels which should be decompressed in lumbar spinal stenosis.

    PubMed

    Chen, Hua-Biao; Zhong, Zhi-Wei; Li, Chun-Sheng; Bai, Bo

    2016-07-01

    In lumbar spinal stenosis, correlating symptoms and physical examination findings with decompression levels based on common imaging is not reliable. Paraspinal mapping (PM) and diffusion tensor imaging (DTI) may be possible to prevent the false positive occurrences with MRI and show clear benefits to reduce the decompression levels of lumbar spinal stenosis than conventional magnetic resonance imaging (MRI) + neurogenic examination (NE). However, they must have enough positive rate with levels which should be decompressed at first. The study aimed to confirm that the positive of DTI and PM is enough in levels which should be decompressed in lumbar spinal stenosis. The study analyzed the positive of DTI and PM as well as compared the preoperation scores to the postoperation scores, which were assessed preoperatively and at 2 weeks, 3 months 6 months, and 12 months postoperatively. 96 patients underwent the single level decompression surgery. The positive rate among PM, DTI, and (PM or DTI) was 76%, 98%, 100%, respectively. All post-operative Oswestry Disability Index (ODI), visual analog scale for back pain (VAS-BP) and visual analog scale for leg pain (VAS-LP) scores at 2 weeks postoperatively were measured improvement than the preoperative ODI, VAS-BP and VAS-LP scores with statistically significance (p-value = 0.000, p-value = 0.000, p-value = 0.000, respectively). In degenetive lumbar spinal stenosis, the positive rate of (DTI or PM) is enough in levels which should be decompressed, thence using the PM and DTI to determine decompression levels will not miss the level which should be operated. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  5. 47 CFR 15.251 - Operation within the bands 2.9-3.26 GHz, 3.267-3.332 GHz, 3.339-3.3458 GHz, and 3.358-3.6 GHz.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... exceed 3000 microvolts/meter/MHz at 3 meters in any direction. Further, an AVIS, when in its operating position, shall not produce a field strength greater than 400 microvolts/meter/MHz at 3 meters in any... maximum of 100 microvolts/meter/MHz at 3 meters, measured from 30 MHz to 20 GHz for the complete system...

  6. Anhedonia reflects impairment in making relative value judgments between positive and neutral stimuli in schizophrenia.

    PubMed

    Strauss, Gregory P; Visser, Katherine Frost; Keller, William R; Gold, James M; Buchanan, Robert W

    2018-02-27

    Anhedonia (i.e., diminished capacity to experience pleasure) has traditionally been viewed as a core symptom of schizophrenia (SZ). However, modern laboratory-based studies suggest that this definition may be incorrect, as hedonic capacity may be intact. Alternative conceptualizations have proposed that anhedonia may reflect an impairment in generating mental representations of affective value that are needed to guide decision-making and initiate motivated behavior. The current study evaluated this hypothesis in 42 outpatients with SZ and 19 healthy controls (CN) who completed two tasks: (a) an emotional experience task that required them to indicate how positive, negative, and calm/excited they felt in response to a single emotional or neutral photograph; (b) a relative value judgment task where they selected which of 2 photographs they preferred. Results indicated that SZ and CN reported similar levels of positive emotion and arousal in response to emotional and neutral stimuli; however, SZ reported higher negative affect for neutral and pleasant stimuli than CN. In the relative value judgment task, CN displayed clear preference for stimuli differing in valence; however, SZ showed less distinct preferences for positive over neutral stimuli. Findings suggest that although in-the-moment experiences of positive emotion to singular stimuli may be intact in SZ, the ability to make relative value judgments that are needed to guide decision-making is impaired. Original conceptualizations of anhedonia as a diminished capacity for pleasure in SZ may be inaccurate; anhedonia may more accurately reflect a deficit in relative value judgment that results from impaired value representation. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. 40 CFR Table 6 to Subpart Uuuu of... - Continuous Compliance With Operating Limits

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... 7. carbon absorber maintain the regeneration frequency, total regeneration stream mass or volumetric flow during carbon bed regeneration and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s)) for each regeneration cycle within the values established...

  8. 40 CFR Table 6 to Subpart Uuuu of... - Continuous Compliance With Operating Limits

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... 7. carbon absorber maintain the regeneration frequency, total regeneration stream mass or volumetric flow during carbon bed regeneration and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s)) for each regeneration cycle within the values established...

  9. 40 CFR Table 6 to Subpart Uuuu of... - Continuous Compliance With Operating Limits

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... 7. carbon absorber maintain the regeneration frequency, total regeneration stream mass or volumetric flow during carbon bed regeneration and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s)) for each regeneration cycle within the values established...

  10. 40 CFR Table 6 to Subpart Uuuu of... - Continuous Compliance With Operating Limits

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... 7. carbon absorber maintain the regeneration frequency, total regeneration stream mass or volumetric flow during carbon bed regeneration and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s)) for each regeneration cycle within the values established...

  11. 40 CFR Table 6 to Subpart Uuuu of... - Continuous Compliance With Operating Limits

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... 7. carbon absorber maintain the regeneration frequency, total regeneration stream mass or volumetric flow during carbon bed regeneration and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s)) for each regeneration cycle within the values established...

  12. Effectiveness of computer-aided diagnosis (CADx) of breast pathology using immunohistochemistry results of core needle biopsy samples for synaptophysin, oestrogen receptor and CK14/p63 for classification of epithelial proliferative lesions of the breast.

    PubMed

    Maeda, Ichiro; Kubota, Manabu; Ohta, Jiro; Shinno, Kimika; Tajima, Shinya; Ariizumi, Yasushi; Doi, Masatomo; Oana, Yoshiyasu; Kanemaki, Yoshihide; Tsugawa, Koichiro; Ueno, Takahiko; Takagi, Masayuki

    2017-12-01

    The aim of this study was to develop a computer-aided diagnosis (CADx) system for identifying breast pathology. Two sets of 100 consecutive core needle biopsy (CNB) specimens were collected for test and validation studies. All 200 CNB specimens were stained with antibodies targeting oestrogen receptor (ER), synaptophysin and CK14/p63. All stained slides were scanned in a whole-slide imaging system and photographed. The photographs were analysed using software to identify the proportions of tumour cells that were positive and negative for each marker. In the test study, the cut-off values for synaptophysin (negative and positive) and CK14/p63 (negative and positive) were decided using receiver operating characteristic (ROC) analysis. For ER analysis, samples were divided into groups with <10% positive or >10% positive cells and decided using receiver operating characteristic (ROC) analysis. Finally, these two groups categorised as ER-low, ER-intermediate (non-low and non-high) and ER-high groups. In the validation study, the second set of immunohistochemical slides were analysed using these cut-off values. The cut-off values for synaptophysin, <10% ER positive, >10% ER positive and CK14/p63 were 0.14%, 2.17%, 77.93% and 18.66%, respectively. The positive predictive value for malignancy (PPV) was 100% for synaptophysin-positive/ER-high/(CK14/p63)-any or synaptophysin-positive/ER-low/(CK14/p63)-any. The PPV was 25% for synaptophysin-positive/ER-intermediate/(CK14/p63)-positive. For synaptophysin-negative/(CK14/p63)-negative, the PPVs for ER-low, ER-intermediate and ER-high were 100%, 80.0% and 95.8%, respectively. The PPV was 4.5% for synaptophysin-negative/ER-intermediate/(CK14/p63)-positive. The CADx system was able to analyse sufficient data for all types of epithelial proliferative lesions of the breast including invasive breast cancer. This system may be useful for pathological diagnosis of breast CNB in routine investigations. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radtke, M.A.

    This paper will chronicle the activity at Wisconsin Public Service Corporation (WPSC) that resulted in the complete migration of a traditional, late 1970`s vintage, Energy Management System (EMS). The new environment includes networked microcomputers, minicomputers, and the corporate mainframe, and provides on-line access to employees outside the energy control center and some WPSC customers. In the late 1980`s, WPSC was forecasting an EMS computer upgrade or replacement to address both capacity and technology needs. Reasoning that access to diverse computing resources would best position the company to accommodate the uncertain needs of the energy industry in the 90`s, WPSC chosemore » to investigate an in-place migration to a network of computers, able to support heterogeneous hardware and operating systems. The system was developed in a modular fashion, with individual modules being deployed as soon as they were completed. The functional and technical specification was continuously enhanced as operating experience was gained from each operational module. With the migration off the original EMS computers complete, the networked system called DEMAXX (Distributed Energy Management Architecture with eXtensive eXpandability) has exceeded expectations in the areas of: cost, performance, flexibility, and reliability.« less

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radtke, M.A.

    This paper will chronicle the activity at Wisconsin Public Service Corporation (WPSC) that resulted in the complete migration of a traditional, late 1970`s vintage, Energy management System (EMS). The new environment includes networked microcomputers, minicomputers, and the corporate mainframe, and provides on-line access to employees outside the energy control center and some WPSC customers. In the late 1980`s, WPSC was forecasting an EMS computer upgrade or replacement to address both capacity and technology needs. Reasoning that access to diverse computing resources would best position the company to accommodate the uncertain needs of the energy industry in the 90`s, WPSC chosemore » to investigate an in-place migration to a network of computers, able to support heterogeneous hardware and operating systems. The system was developed in a modular fashion, with individual modules being deployed as soon as they were completed. The functional and technical specification was continuously enhanced as operating experience was gained from each operational module. With the migration of the original EMS computers complete, the networked system called DEMAXX (Distributed Energy Management Architecture with eXtensive eXpandability) has exceeded expectations in the areas of: cost, performance, flexibility, and reliability.« less

  15. Value of the pinnal-pedal reflex in the diagnosis of canine scabies.

    PubMed

    Mueller, R S; Bettenay, S V; Shipstone, M

    2001-05-19

    The potential value of the pinnal-pedal scratch reflex as an aid to diagnosing canine scabies was assessed in 588 dogs with skin disease. The reflex was assessed by vigorously rubbing the tip of one earflap on to the base of the ear for five seconds, and it was considered positive if the ipsilateral hind leg made a scratching movement. A diagnosis of scabies was based on the dog's history, a physical examination and either positive skin scrapings or the complete resolution of pruritus and dermatitis after treatment with ivermectin or milbemycin, with no relapse for at least 12 months. Scabies was diagnosed in 55 of the dogs, allergic skin disease in 463, and 70 had other miscellaneous skin diseases. There was a positive pinnal-pedal scratch reflex in 45 (82 per cent) of the 55 dogs with scabies. Forty (73 per cent) of the dogs with scabies had pinnal dermatitis, and 36 (90 per cent) of these had a positive pinnal-pedal scratch reflex. There was a positive pinnal-pedal scratch reflex in 33 (6.2 per cent) of the other 533 dogs. On the basis of these results, the specificity of testing for scabies by the pinnal-pedal scratch reflex was 93.8 per cent, and the sensitivity was 81.8 per cent The test's positive predictive value was 0.57 and its negative predictive value was 0.98.

  16. "In our stories": The perspectives of women living with HIV on an evidence-based group intervention.

    PubMed

    Dale, Sannisha K; Grimes, Tiffany; Miller, Lauren; Ursillo, Alyssa; Drainoni, Mari-Lynn

    2017-07-01

    A qualitative study among women living with HIV assessed the aspects of an evidence-based intervention targeting HIV transmission risk reduction (Women Involved in Life Learning from Other Women [WiLLOW]) that women valued and how their lives were impacted. Thirty-one women (80.6% African American) completed interviews. Women valued the personal stories and positive group dynamics (i.e. safety, trust, openness, getting feedback, bonding, and socializing). As a result of WiLLOW, women embraced a strong woman image, joined groups, changed behaviors, accepted their HIV status, became optimistic, and spoke up/advocated in their relationships and communities. Interventions for HIV-positive women may benefit from incorporating the sharing of stories in their curricula and factors that build positive group dynamics.

  17. The influence of newborn early literacy intervention programs in three canadian provinces.

    PubMed

    Letourneau, Nicole; Whitty, Pam; Watson, Barry; Phillips, Jennifer; Joschko, Justin; Gillis, Doris

    2015-01-01

    Low levels of literacy in early childhood can have lasting effects on children's educational and intellectual development. Many countries have implemented newborn literacy programs designed to teach parents pre-literacy promoting activities to share with their children. We conducted 2 quasi-experimental studies using 1) a pre-test/post-test design and 2) a non-equivalent control group design to examine the effect of newborn literacy programs on parents' self-reported literacy intentions/behaviors, values toward literacy, and parent-child interactions. Parents were recruited from 3 provinces, 2 with newborn literacy programs (intervention) and 1 without (control). Parents in the intervention group completed prenatal and postnatal (after participation in program) questionnaires. Parents in the control group completed 1 questionnaire. Questionnaires were designed to capture parents' literacy intentions (prenatal), behaviors (postnatal), values, and parent-child interactions (postnatal). A total of 98 parents were included in study one and 174 were included in study two. Parents' self-reported prenatal intentions and values were higher than their postnatal behaviors and values. Parents in the intervention group exhibited higher literacy behaviors and values and greater enjoyment reading to their children than parents in the control group, though they also reported reading to their children less frequently. Parents in the intervention group had significantly higher Positive Interactive scores than controls. Overall, we found participation in newborn literacy programs positively impacted parenting behaviors and attitudes. Lower postnatal within-group scores (intentions and values versus behaviors and values) may have been the result of participants' high expectations. Given our findings, we recommend that these programs continue.

  18. General Procedure for Protective Cooling and Equipment Evaluations Relative to Heat and Cold Stress

    DTIC Science & Technology

    2008-09-01

    climatic chamber housing the manikin. The most widely accepted test procedures for the operation of a TM are published by the American Society for...describes measurement of the clo value of a complete clothing ensemble. It requires a TM surface temperature of 35ºC and a climatic chamber controlled...Clothing Using a Sweating Manikin” (1) measures the im of a complete clothing ensemble. It requires a TM surface temperature of 35ºC and a climatic

  19. Operational Evaluation of VEGGIE Food Production System in the Habitat Demonstration Unit

    NASA Technical Reports Server (NTRS)

    Stutte, Gary W.; Newsham, Gerard; Morrow, Robert M.; Wheeler, Raymond M.

    2011-01-01

    The 2010 Desert Research and Technology Studies (DRATS) of the VEGGIE Food Production System in the Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) was the first operational evaluation of salad crop production technology in a NASA analog test. A systematic evaluation of rooting media and nutrient delivery systems were evaluated for three lettuce cultivars that have shown promise as candidates for a surface based food production system. The VEGGIE nutrient delivery system worked well, was able to be maintained by multiple operators with a minimum of training, and supported excellent lettuce growth for the duration of the test. A Hazard Analysis and Critical Control Point (HACCP) evaluation was performed using ProSan(tm) as sanitation agent prior to consumption was approved, and the crew was allowed to consume the lettuce grown using the VEGGIE light cap and gravity based nutrient delivery system at the completion of the 14-day DRAT field test. The DRAT field test validated the crew operations; Growth of all lettuce cultivars was excellent. The operational DRAT field testing in the HDU identified light quality issues related to morphology and pigment development that will need to be addressed through additional testing. Feedback from the crew, ground support personnel, and human factors leads was uniformly positive on the psychological value of having the crop production system in the excursion module. A number of areas have been identified for future work, to minimize the "footprint" of the Food Production system through creative use of unused wall and floor space in the unit.

  20. Operation Evaluation of the VEGGIE Food Production System in the Habitat Demonstration Unit

    NASA Technical Reports Server (NTRS)

    Stutte, Gary W.; Newsham, Gerard; Morrow, Robert M.; Wheeler, Raymond M.

    2011-01-01

    The 2010 Desert Research and Technology Studies (DRATS) of the VEGGIE Food Production System in the Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) was the first operational evaluation of salad crop production technology in a NASA analog test. A systematic evaluation of rooting media and nutrient delivery systems were evaluated for three lettuce cultivars that have shown promise as candidates for a surface based food production system. The VEGGIE nutrient delivery system worked well, was able to be maintained by multiple operators with a minimum of training, and supported excellent lettuce growth for the duration of the test. A Hazard Analysis and Critical Control Point (HACCP) evaluation was performed using ProSantm as sanitation agent prior to consumption was approved, and the crew was allowed to consume the lettuce grown using the VEGGIE light cap and gravity based nutrient delivery system at the completion of the 14-day DRAT field test. The DRAT field test validated the crew operations; Growth of all lettuce cultivars was excellent. The operational DRAT field testing in the HDU identified light quality issues related to morphology and pigment development that will need to be addressed through additional testing. Feedback from the crew, ground support personnel, and human factors leads was uniformly positive on the psychological value of having the crop production system in the excursion module. A number of areas have been identified for future work, to minimize the "footprint" of the Food Production system through creative use of unused wall and floor space in the unit.

  1. A new intuitionistic fuzzy rule-based decision-making system for an operating system process scheduler.

    PubMed

    Butt, Muhammad Arif; Akram, Muhammad

    2016-01-01

    We present a new intuitionistic fuzzy rule-based decision-making system based on intuitionistic fuzzy sets for a process scheduler of a batch operating system. Our proposed intuitionistic fuzzy scheduling algorithm, inputs the nice value and burst time of all available processes in the ready queue, intuitionistically fuzzify the input values, triggers appropriate rules of our intuitionistic fuzzy inference engine and finally calculates the dynamic priority (dp) of all the processes in the ready queue. Once the dp of every process is calculated the ready queue is sorted in decreasing order of dp of every process. The process with maximum dp value is sent to the central processing unit for execution. Finally, we show complete working of our algorithm on two different data sets and give comparisons with some standard non-preemptive process schedulers.

  2. Designing quantum information processing via structural physical approximation.

    PubMed

    Bae, Joonwoo

    2017-10-01

    In quantum information processing it may be possible to have efficient computation and secure communication beyond the limitations of classical systems. In a fundamental point of view, however, evolution of quantum systems by the laws of quantum mechanics is more restrictive than classical systems, identified to a specific form of dynamics, that is, unitary transformations and, consequently, positive and completely positive maps to subsystems. This also characterizes classes of disallowed transformations on quantum systems, among which positive but not completely maps are of particular interest as they characterize entangled states, a general resource in quantum information processing. Structural physical approximation offers a systematic way of approximating those non-physical maps, positive but not completely positive maps, with quantum channels. Since it has been proposed as a method of detecting entangled states, it has stimulated fundamental problems on classifications of positive maps and the structure of Hermitian operators and quantum states, as well as on quantum measurement such as quantum design in quantum information theory. It has developed efficient and feasible methods of directly detecting entangled states in practice, for which proof-of-principle experimental demonstrations have also been performed with photonic qubit states. Here, we present a comprehensive review on quantum information processing with structural physical approximations and the related progress. The review mainly focuses on properties of structural physical approximations and their applications toward practical information applications.

  3. Designing quantum information processing via structural physical approximation

    NASA Astrophysics Data System (ADS)

    Bae, Joonwoo

    2017-10-01

    In quantum information processing it may be possible to have efficient computation and secure communication beyond the limitations of classical systems. In a fundamental point of view, however, evolution of quantum systems by the laws of quantum mechanics is more restrictive than classical systems, identified to a specific form of dynamics, that is, unitary transformations and, consequently, positive and completely positive maps to subsystems. This also characterizes classes of disallowed transformations on quantum systems, among which positive but not completely maps are of particular interest as they characterize entangled states, a general resource in quantum information processing. Structural physical approximation offers a systematic way of approximating those non-physical maps, positive but not completely positive maps, with quantum channels. Since it has been proposed as a method of detecting entangled states, it has stimulated fundamental problems on classifications of positive maps and the structure of Hermitian operators and quantum states, as well as on quantum measurement such as quantum design in quantum information theory. It has developed efficient and feasible methods of directly detecting entangled states in practice, for which proof-of-principle experimental demonstrations have also been performed with photonic qubit states. Here, we present a comprehensive review on quantum information processing with structural physical approximations and the related progress. The review mainly focuses on properties of structural physical approximations and their applications toward practical information applications.

  4. 40 CFR 1065.340 - Diluted exhaust flow (CVS) calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-open position. (6) Operate the PDP for at least 3 min to stabilize the system. Continue operating the PDP and record the mean values of at least 30 seconds of sampled data of each of the following... the PDP, p in. (8) Repeat the steps in paragraphs (e)(6) and (7) of this section to record data at a...

  5. The Relationship between Patron-Dependence, Communication and Development: A Look into Social Integration and Socio-Economic Control.

    ERIC Educational Resources Information Center

    Quesada, Gustavo M.

    Personal interviews were conducted in July, 1967, with 315 farm operators in rural Brazil where the local extension service had been in operation for more than four years. Patron-dependence (PD) was described as the subscription to a value system, according to the individual's position in the status structure, which produces dependency at…

  6. Displaying Force and Torque of A Manipulator

    NASA Technical Reports Server (NTRS)

    Bejczy, A. K.; Dotson, R. S.; Primus, H. C.

    1984-01-01

    Display combines bar charts, vector diagrams, and numerical values to inform operator of forces and torques exerted by end effector of manipulator. On voice or keyboard command, eight-channel strip-chart recorder traces force and torque components and claw position of raw measurements from eight strain gage sensors in end effector. Especially helpful when operator's view of end effector is obscured.

  7. Langley Full-Scale Tunnel Investigation of a 1/3-Scale Model of the Chance Vought XF5U-1 Airplane

    NASA Technical Reports Server (NTRS)

    Lange, Roy H.; Cocke, Bennie W., Jr.; Proterra, Anthony J.

    1946-01-01

    The results of an investigation of a 1/3-scale model of the Chance Vought XF5U-1 airplane in the Langley full-scale tunnel are presented in this report. The maximum lift and stalling characteristics of several model configurations, the longitudinal stability characteristics of the model, and the effectiveness of the control surfaces were determined with the propellers removed. The propulsive characteristics, the effect of propeller operation on the lift, and the static thrust of the model propellers were determined at several propeller-blade angles. The results with the propellers removed showed that the maximum lift coefficient of the complete model configuration was only 0.97 was compared with the value of 1.31 for the model configuration in which the engine-air ducts and canopy are removed. The model with the propellers removed (normal center-of-gravity position) has a positive static margin, stick fixed, varying from 5 to 13 percent of the mean aerodynamic chord throughout the unstalled range of lift coefficients. The unit horizontal tail is sufficiently powerful to trim the airplane with the propellers removed throughout the unstalled range of lift coefficients. The peak propulsive efficiencies for beta = 20 degrees and beta = 30 degrees were increased 7 percent at C(sub L) congruent to 0.67 and 20 percent at C(sub L) congruent to 0.74, respectively, with the propellers rotating upward in the center than with the propellers rotating downward in the center. Indications are that the minimum forward-flight speed of the airplane for full-power operation at sea level will be about 90 miles per hour. Decreasing the weight and increasing the power reduced this value of minimum speed and there were no indications from the results of a lower limit to the minimum speed.

  8. Launch vehicle tracking enhancement through Global Positioning System Metric Tracking

    NASA Astrophysics Data System (ADS)

    Moore, T. C.; Li, Hanchu; Gray, T.; Doran, A.

    United Launch Alliance (ULA) initiated operational flights of both the Atlas V and Delta IV launch vehicle families in 2002. The Atlas V and Delta IV launch vehicles were developed jointly with the US Air Force (USAF) as part of the Evolved Expendable Launch Vehicle (EELV) program. Both Launch Vehicle (LV) families have provided 100% mission success since their respective inaugural launches and demonstrated launch capability from both Vandenberg Air Force Base (VAFB) on the Western Test Range and Cape Canaveral Air Force Station (CCAFS) on the Eastern Test Range. However, the current EELV fleet communications, tracking, & control architecture & technology, which date back to the origins of the space launch business, require support by a large and high cost ground footprint. The USAF has embarked on an initiative known as Future Flight Safety System (FFSS) that will significantly reduce Test Range Operations and Maintenance (O& M) cost by closing facilities and decommissioning ground assets. In support of the FFSS, a Global Positioning System Metric Tracking (GPS MT) System based on the Global Positioning System (GPS) satellite constellation has been developed for EELV which will allow both Ranges to divest some of their radar assets. The Air Force, ULA and Space Vector have flown the first 2 Atlas Certification vehicles demonstrating the successful operation of the GPS MT System. The first Atlas V certification flight was completed in February 2012 from CCAFS, the second Atlas V certification flight from VAFB was completed in September 2012 and the third certification flight on a Delta IV was completed October 2012 from CCAFS. The GPS MT System will provide precise LV position, velocity and timing information that can replace ground radar tracking resource functionality. The GPS MT system will provide an independent position/velocity S-Band telemetry downlink to support the current man-in-the-loop ground-based commanded destruct of an anomalous flight- The system utilizes a 50 channel digital receiver capable of navigating in high dynamic environments and high altitudes fed by antennas mounted diametrically opposed on the second stage airframe skin. To enhance cost effectiveness, the GPS MT System design implemented existing commercial parts and common environmental and interface requirements for both EELVs. The EELV GPS MT System design is complete, successfully qualified and has demonstrated that the system performs as simulated. This paper summarizes the current development status, system cost comparison, and performance capabilities of the EELV GPS MT System.

  9. Accuracy of a Digital Impression System Based on Active Triangulation Technology With Blue Light for Implants: Effect of Clinically Relevant Parameters.

    PubMed

    Giménez, Beatriz; Özcan, Mutlu; Martínez-Rus, Francisco; Pradíes, Guillermo

    2015-10-01

    To evaluate the accuracy of a digital impression system considering clinical parameters. A master model with 6 implants (27, 25, 22, 12, 15, and 17) was fitted with polyether ether ketone scan bodies. Implant no. 25 was placed with 30° mesial angulation and no. 15 with 30° distal angulation in relation to the vertical plane (y axis). Implant no. 22 was placed at 2 mm and no. 12 placed 4 mm below the gingiva. Experienced (n = 2) and inexperienced (n = 2) operators performed the scanning (CEREC system). Measurements involved 5 distances (27-25, 27-22, 27-12, 27-15, 27-17). Measurements with coordinated measuring machine of the master model acted as the true values. The experience of the operator affected the accuracy. Operator 3 (inexperienced) performed better than the rest. Angulation and implant depth did not affect the accuracy results. The position of the camera affected the accuracy of the system. The first scanned quadrant had significantly smaller error, -17 ± 26.3 μm, than the second quadrant, -116 ± 103 μm. Digital impressions with CEREC Bluecam system can be a feasible alternative for challenging cases where angulation and depth of the implants are present. The accuracy of the CEREC system for the first scanned quadrant is high, and it decreases when completing a full arch.

  10. 3-D sonography for diagnosis of disk dislocation of the temporomandibular joint compared with MRI.

    PubMed

    Landes, Constantin A; Goral, Wojciech A; Sader, Robert; Mack, Martin G

    2006-05-01

    This study determines the value of three-dimensional (3-D) sonography for the assessment of disk dislocation of the temporomandibular joint (TMJ). Sixty-eight patients (i.e.,136 TMJ) with clinical dysfunction were examined by 272 sonographic 3-D scans. An 8- to 12.5-MHz transducer, angulated by step-motor, was used after picking a volume box on 2-D scan; magnetic resonance imaging followed immediately. Every TMJ was scrutinized in closed- and open-mouth position for normal or dislocated disk position. Fifty-three patients had complete data sets, i.e., 106 TMJ, 212 examinations. Sonographic examination took 5 min, with 74% specificity (62% closed-mouth; 85% open-mouth); sensitivity 53% (62/43%); accuracy 70% (62/77%); positive predictive value 49% (57/41%); and negative predictive value 77% (67/86%). This study encourages more research on the diagnostic capacity of 3-D TMJ sonography, with the advantage of multidimensional joint visualization. Although fair in specificity and negative predictive value, sensitivity and accuracy may ameliorate with future higher-sound frequency, real-time 3-D viewing and automated image analysis.

  11. ISS Operations Cost Reductions Through Automation of Real-Time Planning Tasks

    NASA Technical Reports Server (NTRS)

    Hall, Timothy A.; Clancey, William J.; McDonald, Aaron; Toschlog, Jason; Tucker, Tyson; Khan, Ahmed; Madrid, Steven (Eric)

    2011-01-01

    In 2007 the Johnson Space Center s Mission Operations Directorate (MOD) management team challenged their organizations to find ways to reduce the cost of operations for supporting the International Space Station (ISS) in the Mission Control Center (MCC). Each MOD organization was asked to define and execute projects that would help them attain cost reductions by 2012. The MOD Operations Division Flight Planning Branch responded to this challenge by launching several software automation projects that would allow them to greatly improve console operations and reduce ISS console staffing and intern reduce operating costs. These tasks ranged from improving the management and integration mission plan changes, to automating the uploading and downloading of information to and from the ISS and the associated ground complex tasks that required multiple decision points. The software solutions leveraged several different technologies including customized web applications and implementation of industry standard web services architecture; as well as engaging a previously TRL 4-5 technology developed by Ames Research Center (ARC) that utilized an intelligent agent-based system to manage and automate file traffic flow, archive data, and generate console logs. These projects to date have allowed the MOD Operations organization to remove one full time (7 x 24 x 365) ISS console position in 2010; with the goal of eliminating a second full time ISS console support position by 2012. The team will also reduce one long range planning console position by 2014. When complete, these Flight Planning Branch projects will account for the elimination of 3 console positions and a reduction in staffing of 11 engineering personnel (EP) for ISS.

  12. The viewpoint-specific failure of modern 3D displays in laparoscopic surgery.

    PubMed

    Sakata, Shinichiro; Grove, Philip M; Hill, Andrew; Watson, Marcus O; Stevenson, Andrew R L

    2016-11-01

    Surgeons conventionally assume the optimal viewing position during 3D laparoscopic surgery and may not be aware of the potential hazards to team members positioned across different suboptimal viewing positions. The first aim of this study was to map the viewing positions within a standard operating theatre where individuals may experience visual ghosting (i.e. double vision images) from crosstalk. The second aim was to characterize the standard viewing positions adopted by instrument nurses and surgical assistants during laparoscopic pelvic surgery and report the associated levels of visual ghosting and discomfort. In experiment 1, 15 participants viewed a laparoscopic 3D display from 176 different viewing positions around the screen. In experiment 2, 12 participants (randomly assigned to four clinically relevant viewing positions) viewed laparoscopic suturing in a simulation laboratory. In both experiments, we measured the intensity of visual ghosting. In experiment 2, participants also completed the Simulator Sickness Questionnaire. We mapped locations within the dimensions of a standard operating theatre at which visual ghosting may result during 3D laparoscopy. Head height relative to the bottom of the image and large horizontal eccentricities away from the surface normal were important contributors to high levels of visual ghosting. Conventional viewing positions adopted by instrument nurses yielded high levels of visual ghosting and severe discomfort. The conventional viewing positions adopted by surgical team members during laparoscopic pelvic operations are suboptimal for viewing 3D laparoscopic displays, and even short periods of viewing can yield high levels of discomfort.

  13. Automated simultaneous measurement of the δ(13) C and δ(2) H values of methane and the δ(13) C and δ(18) O values of carbon dioxide in flask air samples using a new multi cryo-trap/gas chromatography/isotope ratio mass spectrometry system.

    PubMed

    Brand, Willi A; Rothe, Michael; Sperlich, Peter; Strube, Martin; Wendeberg, Magnus

    2016-07-15

    The isotopic composition of greenhouse gases helps to constrain global budgets and to study sink and source processes. We present a new system for high-precision stable isotope measurements of carbon, hydrogen and oxygen in atmospheric methane and carbon dioxide. The design is intended for analyzing flask air samples from existing sampling programs without the need for extra sample air for methane analysis. CO2 and CH4 isotopes are measured simultaneously using two isotope ratio mass spectrometers, one for the analysis of δ(13) C and δ(18) O values and the second one for δ(2) H values. The inlet carousel delivers air from 16 sample positions (glass flasks 1-5 L and high-pressure cylinders). Three 10-port valves take aliquots from the sample stream. CH4 from 100-mL air aliquots is preconcentrated in 0.8-mL sample loops using a new cryo-trap system. A precisely calibrated working reference air is used in parallel with the sample according to the Principle of Identical Treatment. It takes about 36 hours for a fully calibrated analysis of a complete carousel including extractions of four working reference and one quality control reference air. Long-term precision values, as obtained from the quality control reference gas since 2012, account for 0.04 ‰ (δ(13) C values of CO2 ), 0.07 ‰ (δ(18) O values of CO2 ), 0.11 ‰ (δ(13) C values of CH4 ) and 1.0 ‰ (δ(2) H values of CH4 ). Within a single day, the system exhibits a typical methane δ(13) C standard deviation (1σ) of 0.06 ‰ for 10 repeated measurements. The system has been in routine operation at the MPI-BGC since 2012. Consistency of the data and compatibility with results from other laboratories at a high precision level are of utmost importance. A high sample throughput and reliability of operation are important achievements of the presented system to cope with the large number of air samples to be analyzed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Does self-administered vaginal misoprostol result in cervical ripening in postmenopausal women after 14 days of pre-treatment with estradiol? Trial protocol for a randomised, placebo-controlled sequential trial.

    PubMed

    Oppegaard, K S; Lieng, M; Berg, A; Istre, O; Qvigstad, E; Nesheim, B-I

    2008-06-01

    To compare the impact of 1000 micrograms of self-administered vaginal misoprostol versus self-administered vaginal placebo on preoperative cervical ripening after pre-treatment with estradiol vaginal tablets at home in postmenopausal women prior to day-care operative hysteroscopy. Randomised double-blind placebo-controlled sequential trial. The boundaries for the sequential trial were calculated on the primary outcomes of a difference of cervical dilatation > or = 1 millimetre, with the assumption of a type 1 error of 0.05 and a power of 0.95. Norwegian university teaching hospital. Postmenopausal women referred for day-care operative hysteroscopy. The women were randomised to either 1000 micrograms of self-administered vaginal misoprostol or self-administered vaginal placebo the evening before day-care operative hysteroscopy. All women had administered a 25-microgram vaginal estradiol tablet daily for 14 days prior to the operation. Preoperative cervical dilatation (difference between misoprostol and placebo group, primary outcome), difference in dilatation before and after administration of misoprostol or placebo, number of women who achieve a preoperative cervical dilatation > or = 5 millimetres, acceptability, complications and side effects (secondary outcomes). Intra-operative findings and distribution of cervical dilatation in the two treatment groups: values are given as median (range) or n (%). Difference in dilatation before and after administration of misoprostol and placebo: values are given as median (range) of intraindividual differences. Percentage of women who achieve a cervical dilatation of > or = 5 mm, percentage of women who were difficult to dilate. Acceptability in the two treatment groups: values are given as completely acceptable n (%), fairly acceptable n (%), fairly unacceptable n (%), completely unacceptable n (%). Pain in the two treatment groups: pain was measured with a visual analogue scale ranging from 0 (no pain) to 10 (unbearable pain): values are given as median (range). Occurrence of side effects in the two treatment groups. Values are given as n (%). Complications given as n (%). No pharmaceutical company was involved in this study. A research grant from the regional research board of Northern Norway has been awarded to finance Dr K.S.O.'s leave from Hammerfest hospital as well as travel expenses between Hammerfest and Oslo, and research courses. The research grant from Prof B.I.N. (Helse Øst) funded the purchase of estradiol tablets, the manufacturing costs of misoprostol and placebo capsules from the hospital pharmacy, as well as the costs incurred for preparing the randomisation schedule and distribution of containers containing capsules to hospital. Prof B.I.N.'s research grant also funded insurance for the study participants. Estimated completion date 31 December 2008.

  15. Advisory Algorithm for Scheduling Open Sectors, Operating Positions, and Workstations

    NASA Technical Reports Server (NTRS)

    Bloem, Michael; Drew, Michael; Lai, Chok Fung; Bilimoria, Karl D.

    2012-01-01

    Air traffic controller supervisors configure available sector, operating position, and work-station resources to safely and efficiently control air traffic in a region of airspace. In this paper, an algorithm for assisting supervisors with this task is described and demonstrated on two sample problem instances. The algorithm produces configuration schedule advisories that minimize a cost. The cost is a weighted sum of two competing costs: one penalizing mismatches between configurations and predicted air traffic demand and another penalizing the effort associated with changing configurations. The problem considered by the algorithm is a shortest path problem that is solved with a dynamic programming value iteration algorithm. The cost function contains numerous parameters. Default values for most of these are suggested based on descriptions of air traffic control procedures and subject-matter expert feedback. The parameter determining the relative importance of the two competing costs is tuned by comparing historical configurations with corresponding algorithm advisories. Two sample problem instances for which appropriate configuration advisories are obvious were designed to illustrate characteristics of the algorithm. Results demonstrate how the algorithm suggests advisories that appropriately utilize changes in airspace configurations and changes in the number of operating positions allocated to each open sector. The results also demonstrate how the advisories suggest appropriate times for configuration changes.

  16. Value of the Gastroesophageal Reflux Disease Questionnaire (GerdQ) in predicting the proton pump inhibitor response in coronary artery disease patients with gastroesophageal reflux-related chest pain.

    PubMed

    He, S; Liu, Y; Chen, Y; Tang, Y; Xu, J; Tang, C

    2016-05-01

    Chest pain experienced by patients with coronary artery disease can be partly due to gastroesophageal reflux-induced chest pain (GERP). Empirical proton pump inhibitor (PPI) therapy has been recommended as an initial clinical approach for treating GERP. However, PPI use may lead to some health problems. The Gastroesophageal Reflux Disease Questionnaire (GerdQ) may represent a noninvasive and cost-effective approach for avoiding PPI misuse and for identifying the appropriate patients for the PPI trial test. The aim of this pilot study was to prospectively evaluate the association between GerdQ scores and PPI response in patients with coronary artery disease (CAD) and GERP to determine whether the GerdQ predicts the PPI response in patients with CAD and GERP and to further validate the clinical application value of the GerdQ. A total of 154 consecutive patients with potential GERP were recruited to complete a GerdQ with subsequent PPI therapy. Based on the PPI trial result, patients were divided into a PPI-positive response group and a PPI-negative response group. The difference in the GerdQ scores between the two groups was assessed. The receiver operating characteristic (ROC) curve of GerdQ score was drawn according to the PPI response as the gold standard. The ability of GerdQ to predict the PPI response was assessed. A total of 96 patients completed the entire study; 62 patients (64.6%) were assigned to the PPI-positive response group, and 34 patients (35.4%) to the PPI-negative response group. The GerdQ score of the PPI-positive response group (8.11 ± 3.315) was significantly higher than that of the PPI-negative response group (4.41 ± 2.743), and the difference was statistically significant (t = 5.863, P = 0.000). The ROC curve was drawn according to a PPI response assessment result with a score above 2 as the gold standard. The area under curve was 0.806. When the critical value of GerdQ score was 7.5, Youden index was up to 0.514, the diagnostic sensitivity was 0.661, and the diagnostic specificity was 0.853. A GerdQ score greater than 7.5 better predicts the response to the PPI trial therapy. There is a strong association between the GerdQ score and the response to PPI therapy. Higher GerdQ scores were predictive of a positive PPI response in CAD patients with GERP. The GerdQ may be a reasonable screening tool for GERP in patients with CAD who are prepared to accept PPI therapy. © 2015 International Society for Diseases of the Esophagus.

  17. Guided mass spectrum labelling in atom probe tomography.

    PubMed

    Haley, D; Choi, P; Raabe, D

    2015-12-01

    Atom probe tomography (APT) is a valuable near-atomic scale imaging technique, which yields mass spectrographic data. Experimental correctness can often pivot on the identification of peaks within a dataset, this is a manual process where subjectivity and errors can arise. The limitations of manual procedures complicate APT experiments for the operator and furthermore are a barrier to technique standardisation. In this work we explore the capabilities of computer-guided ranging to aid identification and analysis of mass spectra. We propose a fully robust algorithm for enumeration of the possible identities of detected peak positions, which assists labelling. Furthermore, a simple ranking scheme is developed to allow for evaluation of the likelihood of each possible identity being the likely assignment from the enumerated set. We demonstrate a simple, yet complete work-chain that allows for the conversion of mass-spectra to fully identified APT spectra, with the goal of minimising identification errors, and the inter-operator variance within APT experiments. This work chain is compared to current procedures via experimental trials with different APT operators, to determine the relative effectiveness and precision of the two approaches. It is found that there is little loss of precision (and occasionally gain) when participants are given computer assistance. We find that in either case, inter-operator precision for ranging varies between 0 and 2 "significant figures" (2σ confidence in the first n digits of the reported value) when reporting compositions. Intra-operator precision is weakly tested and found to vary between 1 and 3 significant figures, depending upon species composition levels. Finally it is suggested that inconsistencies in inter-operator peak labelling may be the largest source of scatter when reporting composition data in APT. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Augmented reality in a tumor resection model.

    PubMed

    Chauvet, Pauline; Collins, Toby; Debize, Clement; Novais-Gameiro, Lorraine; Pereira, Bruno; Bartoli, Adrien; Canis, Michel; Bourdel, Nicolas

    2018-03-01

    Augmented Reality (AR) guidance is a technology that allows a surgeon to see sub-surface structures, by overlaying pre-operative imaging data on a live laparoscopic video. Our objectives were to evaluate a state-of-the-art AR guidance system in a tumor surgical resection model, comparing the accuracy of the resection with and without the system. Our system has three phases. Phase 1: using the MRI images, the kidney's and pseudotumor's surfaces are segmented to construct a 3D model. Phase 2: the intra-operative 3D model of the kidney is computed. Phase 3: the pre-operative and intra-operative models are registered, and the laparoscopic view is augmented with the pre-operative data. We performed a prospective experimental study on ex vivo porcine kidneys. Alginate was injected into the parenchyma to create pseudotumors measuring 4-10 mm. The kidneys were then analyzed by MRI. Next, the kidneys were placed into pelvictrainers, and the pseudotumors were laparoscopically resected. The AR guidance system allows the surgeon to see tumors and margins using classical laparoscopic instruments, and a classical screen. The resection margins were measured microscopically to evaluate the accuracy of resection. Ninety tumors were segmented: 28 were used to optimize the AR software, and 62 were used to randomly compare surgical resection: 29 tumors were resected using AR and 33 without AR. The analysis of our pathological results showed 4 failures (tumor with positive margins) (13.8%) in the AR group, and 10 (30.3%) in the Non-AR group. There was no complete miss in the AR group, while there were 4 complete misses in the non-AR group. In total, 14 (42.4%) tumors were completely missed or had a positive margin in the non-AR group. Our AR system enhances the accuracy of surgical resection, particularly for small tumors. Crucial information such as resection margins and vascularization could also be displayed.

  19. Optimal ergonomics for laparoscopic surgery in minimally invasive surgery suites: a review and guidelines.

    PubMed

    van Det, M J; Meijerink, W J H J; Hoff, C; Totté, E R; Pierie, J P E N

    2009-06-01

    With minimally invasive surgery (MIS), a man-machine environment was brought into the operating room, which created mental and physical challenges for the operating team. The science of ergonomics analyzes these challenges and formulates guidelines for creating a work environment that is safe and comfortable for its operators while effectiveness and efficiency of the process are maintained. This review aimed to formulate the ergonomic challenges related to monitor positioning in MIS. Background and guidelines are formulated for optimal ergonomic monitor positioning within the possibilities of the modern MIS suite, using multiple monitors suspended from the ceiling. All evidence-based experimental ergonomic studies conducted in the fields of laparoscopic surgery and applied ergonomics for other professions working with a display were identified by PubMed searches and selected for quality and applicability. Data from ergonomic studies were evaluated in terms of effectiveness and efficiency as well as comfort and safety aspects. Recommendations for individual monitor positioning are formulated to create a personal balance between these two ergonomic aspects. Misalignment in the eye-hand-target axis because of limited freedom in monitor positioning is recognized as an important ergonomic drawback during MIS. Realignment of the eye-hand-target axis improves personal values of comfort and safety as well as procedural values of effectiveness and efficiency. Monitor position is an important ergonomic factor during MIS. In the horizontal plain, the monitor should be straight in front of each person and aligned with the forearm-instrument motor axis to avoid axial rotation of the spine. In the sagittal plain, the monitor should be positioned lower than eye level to avoid neck extension.

  20. A Study of Discharge Coefficient in Bileaflet Valves

    DTIC Science & Technology

    2001-10-25

    Granados J. Garcia MA. Luque I. Concha M. “Conservative operation for mitral stenosis with densely fibrosed or partially calcified valves. An eight...for aortic valves, whereas a lower value (around 0.7) has been proposed for valves mounted in the mitralic position, on account of the larger upstream...section; in the mitral position, then, a valve will have a smaller discharge coefficient (or Aeff/A ratio) than in the aortic position. Using dC =1

  1. Support for Afghanistan’s Justice Sector: State Department Programs Need Better Management and Stronger Oversight

    DTIC Science & Technology

    2014-01-01

    note that the uraJt report down played the D value or fNL ’s deployment (in Novemher 2012) of the MctaSt’orm business process managemen t .sysl.em...effectiveness of the project operations under t he terms of this agreement . At the termination of the project a completion report shall be issued as an...including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215

  2. Supervisory Control Information Management Research (SCIMR) Studies: Study of Hotkey Operation Relative to Touch Commands in Utility Tasks (SHORTCUT)

    DTIC Science & Technology

    2011-08-01

    Index (NASA TLX) to assess perceived workload. Following completion of both trials, the N and spiral mazes, participants were asked open-ended...applied to get a valid notion of the possibilities multi-touch can afford. Another manner by which to assess the value of multi-touch would be to...Service, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302, and to the Office of

  3. Intermediate coronary revascularization using the Deltastream blood pump: results from an experimental study.

    PubMed

    Litmathe, J; Hansen, E; Feindt, P; Kurt, M; Boeken, U; Gams, E

    2009-01-01

    Myocardial revascularization using a complete heart-lung machine may involve many problems, as do complete off-pump attempts. Thus, it was the aim of this study to evaluate the effects of intermediate on-pump/off-pump myocardial revascularization using the miniaturized Deltastream blood pump, on ischemia and hemolysis, in comparison with standard myocardial revascularization. In a group of 8 mini-pigs, combined on-pump/off-pump myocardial revascularization was performed using the Deltastream blood pump as beating-heart support for the on-pump part of the operation (group A). Seven other animals served as controls and underwent standard myocardial revascularization with the same device as integrated pump of a complete heart-lung machine (group B). Blood samples for blood gas metabolism, creatine kinase (CK), troponin I, lactate dehydrogenase (LDH), and hydroxybutyrate dehydrogenase (HBDH) were taken before and after the entire operation. Comparing the baseline values, the increase of CK was more pronounced in group B than in group A (176.4-/+41.2 to 279.7-/+29 U/L vs. 274-/+142.7 to 288.1-/+118.6 U/L, respectively; p=0.0006). Increase of troponin I was significantly higher in group B than in group A (1-/+0.3 to 2.9-/+1 ng/mL vs. 1.1-/+0.9 to 3-/+3.8 ng/mL, respectively; p=0.002). LDH increase was also more pronounced in group B (231.7-/+54.3 to 299.9-/+39.8 U/L vs. 274.9-/+59.7 to 263.8-/+57.9 U/L, respectively; p=0.01). HBDH values increased significantly in group B after the operation (group A: 215.9-/+34.7 to 200-/+39.2 U/L vs. group B: 195.4-/+41.7 to 274.9-/+51.6 U/L; p=0.02). Hemodynamic measures and LDH values under luxation (group A: 1.9-/+0.6 U/L; B: 3.5-/+1 U/L,p=0.001) were also superior in the study group. The current set-up might be superior to conventional extracorporeal circulation and thus be an alternative for high-risk candidates to avoid the adverse events of a complete heart-lung machine, when they are scheduled for complete myocardial revascularization.

  4. Classical Information Storage in an n-Level Quantum System

    NASA Astrophysics Data System (ADS)

    Frenkel, Péter E.; Weiner, Mihály

    2015-12-01

    A game is played by a team of two—say Alice and Bob—in which the value of a random variable x is revealed to Alice only, who cannot freely communicate with Bob. Instead, she is given a quantum n-level system, respectively a classical n-state system, which she can put in possession of Bob in any state she wishes. We evaluate how successfully they managed to store and recover the value of x by requiring Bob to specify a value z and giving a reward of value f ( x, z) to the team. We show that whatever the probability distribution of x and the reward function f are, when using a quantum n-level system, the maximum expected reward obtainable with the best possible team strategy is equal to that obtainable with the use of a classical n-state system. The proof relies on mixed discriminants of positive matrices and—perhaps surprisingly—an application of the Supply-Demand Theorem for bipartite graphs. As a corollary, we get an infinite set of new, dimension dependent inequalities regarding positive operator valued measures and density operators on complex n-space. As a further corollary, we see that the greatest value, with respect to a given distribution of x, of the mutual information I ( x; z) that is obtainable using an n-level quantum system equals the analogous maximum for a classical n-state system.

  5. Value as a parameter to consider in operational strategies for CSP plants

    NASA Astrophysics Data System (ADS)

    de Meyer, Oelof; Dinter, Frank; Govender, Saneshan

    2017-06-01

    This paper introduced a value parameter to consider when analyzing operational strategies for CSP plants. The electric system in South Africa, used as case study, is severely constrained with an influx of renewables in the early phase of deployment. The energy demand curve for the system is analyzed showing the total wind and solar photovoltaic contributions for winter and summer. Due to the intermittent nature and meteorological operating conditions of wind and solar photovoltaic plants, the value of CSP plants within the electric system is introduced. Analyzing CSP plants based on the value parameter alone will remain only a philosophical view. Currently there is no quantifiable measure to translate the philosophical view or subjective value and it solely remains the position of the stakeholder. By introducing three other parameters, Cost, Plant and System to a holistic representation of the Operating Strategies of generation plants, the Value parameter can be translated into a quantifiable measure. Utilizing the country's current procurement program as case study, CSP operating under the various PPA within the Bid Windows are analyzed. The Value Cost Plant System diagram developed is used to quantify the value parameter. This paper concluded that no value is obtained from CSP plants operating under the Bid Window 1 & 2 Power Purchase Agreement. However, by recognizing the dispatchability potential of CSP plants in Bid Window 3 & 3.5, the value of CSP in the electric system can be quantified utilizing Value Added Relationship VCPS-diagram. Similarly ancillary services to the system were analyzed. One of the relationships that have not yet been explored within the industry is an interdependent relationship. It was emphasized that the cost and value structure is shared between the plant and system. Although this relationship is functional when the plant and system belongs to the same entity, additional value is achieved by marginalizing the cost structure. A tradeoff between the plant performance indicators and system operations are achieved. CSP plants have demonstrated its capabilities by adapting to various operating strategies. With adequate storage capabilities and appropriate system boundary conditions in place, CSP plants offer solutions as base-load generation plants, peaking plants, intermittent generation and ancillary services to the system. Depending on the electric system structure, the value obtained from CSP plants are quantifiable under the right boundary conditions. An interdependent relationship between the plant and system attains the most value in operating strategies for CSP.

  6. Late-developing infection following posterior fusion for adolescent idiopathic scoliosis.

    PubMed

    Di Silvestre, Mario; Bakaloudis, Georgios; Lolli, Francesco; Giacomini, Stefano

    2011-05-01

    This study is a retrospective case series review of patients with adolescent idiopathic scoliosis (AIS) who were revised more than 1 year after the index procedure, due to a late-developing deep wound infection, to determine onset, bacteriology, possible influence of implant alloy (titanium vs. stainless-steel) and treatment outcome of patients. From a total of 540 patients who underwent posterior-only fusion for AIS from 1993 through 2005 at our institution, 15 cases (2.77%) were revised due to a late-developing post-operative infection: there were six males and nine females, with an average age at initial surgery of 15.8 years (range 12-18). Late infections occurred at a mean of 70 months (15-95) after the index procedure. The implant alloy used was a stainless-steel instrumentation in 11 patients (4.56% of 241) and a titanium one in 4 patients (1.33% of 299): there was an higher incidence of late infections in stainless-steel alloy group of patients (P < 0.0001). Complete removal of instrumentation was performed in nine patients, obtaining in all cases wound healing and no symptoms of infection, at a minimum 3 years follow-up. In the other six patients, presenting less severe clinical signs of infections, an attempt to save/replace the previous instrumentation was performed, but a complete instrumentation removal had to be performed 11.6 months later (range 3-24) for the persistence or recurrence of infection: all patients healed uneventfully at a minimum 3 years follow-up. Intraoperative cultures were obtained in all 15 cases, being positive in 13 cases (S. epidermidis in 5 patients, S. aureus in 3, Propionibacterium acnes in 1, Serratia marcescens in 1, Propionibacterium acnes + S. epidermidis in 1, S. aureus + S. epidermidis in 1 and coagulase-negative Staphylococci in 1). None presented at latest follow-up scoliosis progression: there was no statistically significant difference between final and pre-operative revision surgery values (P = 0.17). In conclusion, treatment of late-developing post-operative infection in AIS surgery required complete removal of the implant, continuous drain and adequate antibiotic therapy based on intraoperative swab antibiogram. Titanium alloy instrumentations resulted less subject to late post-operative infections, when compared to stainless-steel ones (P < 0.0001).

  7. Evolution of seismicity in relation to fluid injection in the North-Western part of The Geysers geothermal field

    NASA Astrophysics Data System (ADS)

    Leptokaropoulos, Konstantinos; Staszek, Monika; Lasocki, Stanisław; Martínez-Garzón, Patricia; Kwiatek, Grzegorz

    2018-02-01

    The Geysers geothermal field located in California, USA, is the largest geothermal site in the world, operating since the 1960s. We here investigate and quantify the correlation between temporal seismicity evolution and variation of the injection data by examination of time-series through specified statistical tools (binomial test to investigate significant rate changes, cross correlation between seismic and injection data, b-value variation analysis). To do so, we utilize seismicity and operational data associated with two injection wells (Prati-9 and Prati-29) which cover a time period of approximately 7 yr (from November 2007 to August 2014). The seismicity is found to be significantly positively correlated with the injection rate. The maximum correlation occurs with a seismic response delay of ˜2 weeks, following injection operations. Those results are very stable even after considering hypocentral uncertainties, by applying a vertical shift of the events foci up to 300 m. Our analysis indicates also time variations of b-value, which exhibits significant positive correlation with injection rates.

  8. 3D Surgical Simulation

    PubMed Central

    Cevidanes, Lucia; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael

    2009-01-01

    This paper discusses the development of methods for computer-aided jaw surgery. Computer-aided jaw surgery allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery (CAS) system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3D surface models from Cone-beam CT (CBCT), dynamic cephalometry, semi-automatic mirroring, interactive cutting of bone and bony segment repositioning. A virtual setup can be used to manufacture positioning splints for intra-operative guidance. The system provides further intra-operative assistance with the help of a computer display showing jaw positions and 3D positioning guides updated in real-time during the surgical procedure. The CAS system aids in dealing with complex cases with benefits for the patient, with surgical practice, and for orthodontic finishing. Advanced software tools for diagnosis and treatment planning allow preparation of detailed operative plans, osteotomy repositioning, bone reconstructions, surgical resident training and assessing the difficulties of the surgical procedures prior to the surgery. CAS has the potential to make the elaboration of the surgical plan a more flexible process, increase the level of detail and accuracy of the plan, yield higher operative precision and control, and enhance documentation of cases. Supported by NIDCR DE017727, and DE018962 PMID:20816308

  9. Small business employers' views on hiring individuals with mental illness.

    PubMed

    Hand, Carri; Tryssenaar, Joyce

    2006-01-01

    This study investigated the beliefs of small business employers regarding hiring individuals with mental illness. Fifty-eight participants completed mail-in questionnaires concerning beliefs and willingness to hire persons with mental illness. Employers were most concerned regarding the social and emotional skills of individuals with mental illness. Those employers who reported positive beliefs, had positive interactions with individuals with mental illness, or operated in public/social services, stated greater willingness to hire a person with mental illness. Methods to decrease stigma are discussed.

  10. Positioning of the patient during shoulder surgery: an inexpensive, safe and easy technique.

    PubMed

    Van Tongel, Alexander; Hardeman, François; Karelse, Anne; de Wilde, Lieven

    2013-01-01

    The knowledge of shoulder pathology has improved tremendously in the last decades, and shoulder surgery is increasingly performed because of new treatment options and better operative results. Nowadays most surgical shoulder procedures are performed in the sitting or semi-sitting (beach chair) position. Stability of the patient and the ability to flex, extend and rotate the shoulder during surgery are crucial to improve exposure of the surgical field and lower the risk of perioperative complications. We developed an easy, safe and inexpensive surgical set-up providing a very good posterior, superior and anterior access to the shoulder in the sitting or semi-sitting position. In this technique, the patient is placed supine with the head at the foot end of the table and the body positioned slightly eccentrically with the back being supported by the leg plate contralateral to the operative side, avoiding any contact with the scapula of the operative side. A neck support is attached on an extra bar at the contralateral side and accommodated to the patient's lordosis. Next, the leg plate on the operative side is removed, and the head and the body are secured to the table with adhesive dressing. This way a stable positioning of the patient is obtained during the whole procedure, and the shoulder girdle is completely free. The set-up can accommodate patients of different stature and weight without the need to adapt the technique. This position also gives the possibility to provide an excellent radiographic view of the shoulder during operative fracture treatment. Our technique further allows a significant reduction in costs. A surgical table, extra bar, additional arm support and neck support are usually available and can be used in different settings, without the need for a specific shoulder table.

  11. Effect of processing on nutritive values of milk protein.

    PubMed

    Borad, Sanket G; Kumar, Anuj; Singh, Ashish K

    2017-11-22

    Milk is an essential source of nutritionally excellent quality protein in human, particularly in vegan diet. Before consumption, milk is invariably processed depending upon final product requirement. This processing may alter the nutritive value of protein in a significant manner. The processing operations like thermal treatment, chemical treatment, biochemical processing, physical treatments, nonconventional treatments, etc. may exert positive or negative influence on nutritional quality of milk proteins. On one side, processing enhances the nutritive and therapeutic values of protein while on other side intermediate or end products generated during protein reactions may cause toxicity and/or antigenicity upon consumption at elevated level. The review discusses the changes occurring in nutritive quality of milk proteins under the influence of various processing operations.

  12. Audio-Visual Equipment Depreciation. RDU-75-07.

    ERIC Educational Resources Information Center

    Drake, Miriam A.; Baker, Martha

    A study was conducted at Purdue University to gather operational and budgetary planning data for the Libraries and Audiovisual Center. The objectives were: (1) to complete a current inventory of equipment including year of purchase, costs, and salvage value; (2) to determine useful life data for general classes of equipment; and (3) to determine…

  13. 40 CFR 98.255 - Procedures for estimating missing data.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Procedures for estimating missing data... estimating missing data. A complete record of all measured parameters used in the GHG emissions calculations... during unit operation or if a required fuel sample is not taken), a substitute data value for the missing...

  14. 40 CFR 98.85 - Procedures for estimating missing data.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 21 2011-07-01 2011-07-01 false Procedures for estimating missing data... missing data. A complete record of all measured parameters used in the GHG emissions calculations in § 98... substitute data value for the missing parameter shall be used in the calculations. The owner or operator must...

  15. 40 CFR 98.85 - Procedures for estimating missing data.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 22 2012-07-01 2012-07-01 false Procedures for estimating missing data... missing data. A complete record of all measured parameters used in the GHG emissions calculations in § 98... substitute data value for the missing parameter shall be used in the calculations. The owner or operator must...

  16. 40 CFR 98.85 - Procedures for estimating missing data.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Procedures for estimating missing data... missing data. A complete record of all measured parameters used in the GHG emissions calculations in § 98... substitute data value for the missing parameter shall be used in the calculations. The owner or operator must...

  17. 40 CFR 98.85 - Procedures for estimating missing data.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Procedures for estimating missing data... missing data. A complete record of all measured parameters used in the GHG emissions calculations in § 98... substitute data value for the missing parameter shall be used in the calculations. The owner or operator must...

  18. 40 CFR 98.255 - Procedures for estimating missing data.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Procedures for estimating missing data... estimating missing data. A complete record of all measured parameters used in the GHG emissions calculations... during unit operation or if a required fuel sample is not taken), a substitute data value for the missing...

  19. 40 CFR 98.255 - Procedures for estimating missing data.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 21 2011-07-01 2011-07-01 false Procedures for estimating missing data... estimating missing data. A complete record of all measured parameters used in the GHG emissions calculations... during unit operation or if a required fuel sample is not taken), a substitute data value for the missing...

  20. 40 CFR 98.255 - Procedures for estimating missing data.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Procedures for estimating missing data... estimating missing data. A complete record of all measured parameters used in the GHG emissions calculations... during unit operation or if a required fuel sample is not taken), a substitute data value for the missing...

  1. 40 CFR 98.255 - Procedures for estimating missing data.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 22 2012-07-01 2012-07-01 false Procedures for estimating missing data... estimating missing data. A complete record of all measured parameters used in the GHG emissions calculations... during unit operation or if a required fuel sample is not taken), a substitute data value for the missing...

  2. CRP in acute appendicitis--is it a necessary investigation?

    PubMed

    Amalesh, T; Shankar, M; Shankar, R

    2004-01-01

    Appendectomy is one of the commonest procedures in surgery. In spite of various investigations used to improve the accuracy of diagnosis, the rate of normal appendices removed is still about 15-30%. Many studies have investigated the role of C-reactive protein (CRP) in acute appendicitis, but with conflicting results. In a prospective, double blind study, blood for the measurement of serum C-reactive protein was collected pre-operatively from 192 children before going to the operating theatre for appendectomy. The histopathology was grouped into positive (acute appendicitis) and negative (normal appendix) and this was correlated with CRP values. CRP was normal in 14 out of 33 negative explorations (normal appendix on histopathology). The specificity and sensitivity of serum CRP was 42% and 91% respectively. The predictive value of a positive (raised CRP) and negative (normal CRP) test is 88% and 48% respectively. We conclude that neither raised nor normal CRP value is helpful in the diagnosis of acute appendicitis. CRP is not a good tool for helping the surgeon make the diagnosis of appendicitis and it should not be measured in suspected appendicitis.

  3. Method and system for controlling a permanent magnet machine

    DOEpatents

    Walters, James E.

    2003-05-20

    Method and system for controlling the start of a permanent magnet machine are provided. The method allows to assign a parameter value indicative of an estimated initial rotor position of the machine. The method further allows to energize the machine with a level of current being sufficiently high to start rotor motion in a desired direction in the event the initial rotor position estimate is sufficiently close to the actual rotor position of the machine. A sensing action allows to sense whether any incremental changes in rotor position occur in response to the energizing action. In the event no changes in rotor position are sensed, the method allows to incrementally adjust the estimated rotor position by a first set of angular values until changes in rotor position are sensed. In the event changes in rotor position are sensed, the method allows to provide a rotor alignment signal as rotor motion continues. The alignment signal allows to align the estimated rotor position relative to the actual rotor position. This alignment action allows for operating the machine over a wide speed range.

  4. Diver Relative UUV Navigation for Joint Human-Robot Operations

    DTIC Science & Technology

    2013-09-01

    loop response: (10) where Kej is the gain that scales the position error to force . Substituting the measured values for ζ and ων as well as the...Underwater Vehicle; Tethered ; Hovering; Autonomous Underwater Vehicle; Joint human-robot operations; dynamic, uncertain environments 15. NUMBER OF PAGES...4   Figure 3.   The SeaBotix vLBV300 tethered AUV platform (left), and the planar vectored thruster

  5. Orientation based on nursing diagnoses. Old concepts in today's practice.

    PubMed

    Anderson, L K; Vincent, N

    1991-10-01

    Although many operating room orientation programs contain content necessary to meet accrediting guidelines, very few tie the nursing process to the content. Our orientation is structured within a nursing framework (ie, Dr Gordon's "Eleven Functional Health Patterns") and emphasizes nursing diagnoses, theory, and clinical competencies. Although the new orientation program has been in effect for only two years, we feel the following list reflects the positive outcomes so far: decreased staff turnover (ie, one nurse out of 26 full-time equivalents in 18 months), increased success in recruiting nurses into the operating room (ie, multiple applicants as positions open), new nurses demonstrate comfort with basic perioperative nursing practice with-in six months, and nurses who did not complete new orientation program are requesting all or portions of the content. By using this plan, essential aspects of perioperative practice are consistent with hospital-wide nursing practice, practice standards for the operating room, and accrediting standards.

  6. Interview with Janet Woodcock.

    PubMed

    Woodcock, Janet

    2010-09-01

    Dr Janet Woodcock is the Director of the US FDA's Center for Drug Evaluation and Research. Dr Woodcock has held various positions within the FDA's Office of the Commissioner from October 2003 until 1 April 2008, as Deputy Commissioner and Chief Medical Officer, Deputy Commissioner for Operations and Chief Operating Officer and Director of the Critical Path Programs. She oversaw scientific and medical regulatory operations for the FDA. Dr Woodcock served as Director of the Center for Drug Evaluation and Research at the FDA from 1994 to 2005. She previously served in other positions at the FDA, including Director of the Office of Therapeutics Research and Review and Acting Deputy Director of the Center for Biologics Evaluation and Research. Dr Woodcock received her MD from Northwestern Medical School (IL, USA), and completed further training and held teaching appointments at the Pennsylvania State University (PA, USA) and the University of California in San Francisco (CA, USA). She joined the FDA in 1986.

  7. Outlier Removal in Model-Based Missing Value Imputation for Medical Datasets.

    PubMed

    Huang, Min-Wei; Lin, Wei-Chao; Tsai, Chih-Fong

    2018-01-01

    Many real-world medical datasets contain some proportion of missing (attribute) values. In general, missing value imputation can be performed to solve this problem, which is to provide estimations for the missing values by a reasoning process based on the (complete) observed data. However, if the observed data contain some noisy information or outliers, the estimations of the missing values may not be reliable or may even be quite different from the real values. The aim of this paper is to examine whether a combination of instance selection from the observed data and missing value imputation offers better performance than performing missing value imputation alone. In particular, three instance selection algorithms, DROP3, GA, and IB3, and three imputation algorithms, KNNI, MLP, and SVM, are used in order to find out the best combination. The experimental results show that that performing instance selection can have a positive impact on missing value imputation over the numerical data type of medical datasets, and specific combinations of instance selection and imputation methods can improve the imputation results over the mixed data type of medical datasets. However, instance selection does not have a definitely positive impact on the imputation result for categorical medical datasets.

  8. Discrete Radon transform has an exact, fast inverse and generalizes to operations other than sums along lines

    PubMed Central

    Press, William H.

    2006-01-01

    Götz, Druckmüller, and, independently, Brady have defined a discrete Radon transform (DRT) that sums an image's pixel values along a set of aptly chosen discrete lines, complete in slope and intercept. The transform is fast, O(N2log N) for an N × N image; it uses only addition, not multiplication or interpolation, and it admits a fast, exact algorithm for the adjoint operation, namely backprojection. This paper shows that the transform additionally has a fast, exact (although iterative) inverse. The inverse reproduces to machine accuracy the pixel-by-pixel values of the original image from its DRT, without artifacts or a finite point-spread function. Fourier or fast Fourier transform methods are not used. The inverse can also be calculated from sampled sinograms and is well conditioned in the presence of noise. Also introduced are generalizations of the DRT that combine pixel values along lines by operations other than addition. For example, there is a fast transform that calculates median values along all discrete lines and is able to detect linear features at low signal-to-noise ratios in the presence of pointlike clutter features of arbitrarily large amplitude. PMID:17159155

  9. Discrete Radon transform has an exact, fast inverse and generalizes to operations other than sums along lines.

    PubMed

    Press, William H

    2006-12-19

    Götz, Druckmüller, and, independently, Brady have defined a discrete Radon transform (DRT) that sums an image's pixel values along a set of aptly chosen discrete lines, complete in slope and intercept. The transform is fast, O(N2log N) for an N x N image; it uses only addition, not multiplication or interpolation, and it admits a fast, exact algorithm for the adjoint operation, namely backprojection. This paper shows that the transform additionally has a fast, exact (although iterative) inverse. The inverse reproduces to machine accuracy the pixel-by-pixel values of the original image from its DRT, without artifacts or a finite point-spread function. Fourier or fast Fourier transform methods are not used. The inverse can also be calculated from sampled sinograms and is well conditioned in the presence of noise. Also introduced are generalizations of the DRT that combine pixel values along lines by operations other than addition. For example, there is a fast transform that calculates median values along all discrete lines and is able to detect linear features at low signal-to-noise ratios in the presence of pointlike clutter features of arbitrarily large amplitude.

  10. Operating characteristics of six response distortion indicators for the personality assessment inventory.

    PubMed

    Morey, L C; Lanier, V W

    1998-09-01

    The characteristics of six different indicators of response distortion on the Personality Assessment Inventory (PAI; Morey, 1991) were evaluated by having college students complete the PAI under positive impression management, malingering, and honest responding conditions. The six indicators were the PAI Positive Impression (PIM) and Negative Impression (NIM) scales, the Malingering and Defensiveness Indexes, and two discriminant functions, one developed by Cashel and the other by Rogers. Protocols of students asked to malinger were compared with those of actual clinical patients, while protocols of students asked to manage their impression in a positive direction were compared with those of students asked to respond honestly. Comparisons between groups were accomplished through the examination of effect sizes and receiver operating characteristic (ROC) curves. All six indicators demonstrated the ability to distinguish between actual and feigned responding. The Rogers function was particularly effective in identifying malingering. The Cashel function was less effective than other measures in identifying positive impression management, although it appears to also have promise as an indicator of malingering.

  11. Flexible roof drill for low coal. Volume 2. Phase III and Phase IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shoup, N.H.

    1977-09-01

    Design specifications were developed for a flexible drilling and bolting system. The system configuration is based on the use of the Galis dual-boom roof drill as a vehicle for the drilling/bolting system. The WSU Flex-drill drivehead is mounted on the Galis drill boom and the Galis parts are modified to accommodate the revised system. The flexible drillhead supports a bolt bender/inserter designed by Bendix Corporation and is integrated into the system operation. A supplemental bolt thruster was designed to complete insertion of the roof bolt following operation and removal of the Bendix bender from the bolt shank. The complete cyclemore » of drilling a 1-3/8-in. diameter bolt hole, bending a roof bolt into the hole, thrusting the bolt head and washer to the roof surface, and final torquing of the bolt is manually controlled by the operator located in the new position behind the bolting line. The new operating position is beneath newly bolted roof in a safer location in back of the stab jack ad roof jacks positioning the drill boom and drivehead. The Flex-drill/bolting system prototype was constructed from both purchased components and parts specially fabricated in the shops for this design. This unit was assembled and test-operated with appropriate support equipment in a laboratory test stand. Numerous test holes were drilled in blocks of concrete at feed rates of 5 ft/min with drill rotation speeds of 360 rpm. The drill feeds uniformly and cuts smoothly with no difficulty in collection of dust or clogging of the drill bit. The holes drilled were straight, as evidence by passage of a 1-1/4-in. diameter bar full depth into the hole with no binding or evidence of curvature. The flexible drill is capable of drilling 8-ft-deep roof bolt holes in low coal 36 in. in height.« less

  12. Academic motivation, self-concept, engagement, and performance in high school: key processes from a longitudinal perspective.

    PubMed

    Green, Jasmine; Liem, Gregory Arief D; Martin, Andrew J; Colmar, Susan; Marsh, Herbert W; McInerney, Dennis

    2012-10-01

    The study tested three theoretically/conceptually hypothesized longitudinal models of academic processes leading to academic performance. Based on a longitudinal sample of 1866 high-school students across two consecutive years of high school (Time 1 and Time 2), the model with the most superior heuristic value demonstrated: (a) academic motivation and self-concept positively predicted attitudes toward school; (b) attitudes toward school positively predicted class participation and homework completion and negatively predicted absenteeism; and (c) class participation and homework completion positively predicted test performance whilst absenteeism negatively predicted test performance. Taken together, these findings provide support for the relevance of the self-system model and, particularly, the importance of examining the dynamic relationships amongst engagement factors of the model. The study highlights implications for educational and psychological theory, measurement, and intervention. Copyright © 2012 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  13. Cognitive Aids for Role Definition (CARD) to improve interprofessional team crisis resource management: An exploratory study.

    PubMed

    Renna, Tania Di; Crooks, Simone; Pigford, Ashlee-Ann; Clarkin, Chantalle; Fraser, Amy B; Bunting, Alexandra C; Bould, M Dylan; Boet, Sylvain

    2016-09-01

    This study aimed to assess the perceived value of the Cognitive Aids for Role Definition (CARD) protocol for simulated intraoperative cardiac arrests. Sixteen interprofessional operating room teams completed three consecutive simulated intraoperative cardiac arrest scenarios: current standard, no CARD; CARD, no CARD teaching; and CARD, didactic teaching. Each team participated in a focus group interview immediately following the third scenario; data were transcribed verbatim and qualitatively analysed. After 6 months, participants formed eight new teams randomised to two groups (CARD or no CARD) and completed a retention intraoperative cardiac arrest simulation scenario. All simulation sessions were video recorded and expert raters assessed team performance. Qualitative analysis of the 16 focus group interviews revealed 3 thematic dimensions: role definition in crisis management; logistical issues; and the "real life" applicability of CARD. Members of the interprofessional team perceived CARD very positively. Exploratory quantitative analysis found no significant differences in team performance with or without CARD (p > 0.05). In conclusion, qualitative data suggest that the CARD protocol clarifies roles and team coordination during interprofessional crisis management and has the potential to improve the team performance. The concept of a self-organising team with defined roles is promising for patient safety.

  14. Tomography of quantum detectors

    NASA Astrophysics Data System (ADS)

    Lundeen, J. S.; Feito, A.; Coldenstrodt-Ronge, H.; Pregnell, K. L.; Silberhorn, Ch.; Ralph, T. C.; Eisert, J.; Plenio, M. B.; Walmsley, I. A.

    2009-01-01

    Measurement connects the world of quantum phenomena to the world of classical events. It has both a passive role-in observing quantum systems-and an active one, in preparing quantum states and controlling them. In view of the central status of measurement in quantum mechanics, it is surprising that there is no general recipe for designing a detector that measures a given observable. Compounding this, the characterization of existing detectors is typically based on partial calibrations or elaborate models. Thus, experimental specification (that is, tomography) of a detector is of fundamental and practical importance. Here, we present the realization of quantum detector tomography. We identify the positive-operator-valued measure describing the detector, with no ancillary assumptions. This result completes the triad, state, process and detector tomography, required to fully specify an experiment. We characterize an avalanche photodiode and a photon-number-resolving detector capable of detecting up to eight photons. This creates a new set of tools for accurately detecting and preparing non-classical light.

  15. Use of day 1 early morning cortisol to predict the need for glucocorticoid replacement after pituitary surgery.

    PubMed

    Bondugulapati, L N Rao; Campbell, Christopher; Chowdhury, Sharmistha Roy; Goetz, Pablo; Davies, J Stephen; Rees, D Aled; Hayhurst, Caroline

    2016-01-01

    Assessment of adrenal reserve in patients who have undergone pituitary surgery is crucial. However, there is no clear consensus with regards to the type and timing of the test that should be used in the immediate post-operative period. Recently, there has been increased interest in measuring post-operative cortisol levels. We present our data utilising day 1 post-operative early morning cortisol as a tool to assess adrenal reserve in steroid-naive patients. A retrospective analysis of endoscopic pituitary surgery undertaken over a 2-year period. 82 patients underwent 84 surgeries in total. Patients who were already on glucocorticoids pre-operatively and patients with Cushing's disease, pituitary apoplexy and those without follow-up data were excluded, leaving a study group of 44 patients with 45 operations. A 9am day 1 post-operative cortisol value of > 400 nmol/L was taken as an indicator of adequate adrenal reserve. All the patients were reassessed at 6 weeks with a standard short synacthen test (SST) using 250 micrograms of intravenous synacthen. 22 out of 45 patients had a cortisol value of > 400 nmol/L on day 1 post-operatively and were discharged without glucocorticoid supplementation. Of these, only 2 patients subsequently failed the SST when reassessed at 6-8 weeks. The remaining 23 patients had a cortisol value of < 400 nmol/L on day 1 post-operatively and were discharged on hydrocortisone 10 mg twice daily. At 6-8 weeks, nine continued to show suboptimal stimulated cortisol levels whereas the remaining fourteen patients showed adequate adrenal reserve. The 9 am cortisol value had high specificity (81.8%) and positive predictive value (90.9%) for integrity of the HPA axis. Sensitivity was 58.8% and negative predictive value was 39.1%. A day 1 post-operative early morning cortisol is a useful tool to predict adrenal reserve post-pituitary surgery, enabling clinicians to avoid unnecessary blanket glucocorticoid replacement.

  16. Fail-fixed servovalve with positive fluid feedback

    NASA Technical Reports Server (NTRS)

    Kast, Howard B. (Inventor)

    1984-01-01

    The servovalve includes a primary jet of fluid. A variable control signal is adapted to vary the angular position of the primary jet from its maximum recovery position. A first fluid path is adapted to supply fluid to a servopiston at a variable pressure determined at least in part by the control signal. A second fluid path is adapted to receive a predetermined portion of the primary jet fluid when the control signal reaches a predetermined value. The second fluid path terminates in the vicinity of the primary jet and is adapted to direct a secondary jet of fluid at the primary jet to deflect the primary jet toward the input orifice of the second fluid path. The resultant positive fluid feedback in the second fluid path causes the primary jet to latch in a first angular position relative to the maximum recovery position when the control signal reaches a predetermined value. The servovalve may further include a means to discharge the fluid and a means to block the first fluid path to the servopiston when the control signal falls below a second predetermined value. A method of operating a fail-fixed servovalve is also described.

  17. Sniffing position combined with mouth opening improves facemask ventilation in children with adenotonsillar hypertrophy.

    PubMed

    Cuvas, O; Dikmen, B; Yucel, F

    2011-05-01

    This study evaluates the influence of sniffing position combined with mouth opening on the effectiveness of facemask ventilation in paralyzed pediatric patients undergoing adenotonsillectomy during sevoflurane-N(2)O anesthesia. After Institutional Ethics Committee approval, 40 children 5-11 years of age who were scheduled for an elective adenotonsillectomy operation were enrolled in this prospective randomized study. After routine monitoring and pre-oxygenation, anesthesia was induced with sevoflurane 8% in a mixture of 50% N(2)O-O(2). Three minutes after the administration of vecuronium, the sequence of the positions was randomized. Three positions were applied during facemask ventilation: Position CN (closed mouth - neutral head and neck position), position CS (closed mouth-sniffing position) and position OS (opened mouth-sniffing position). Volume-controlled ventilation was started. Peak inspiratory pressure (PIP), tidal volume (V(T)), expired tidal volume (V(Texp)) and end-tidal CO(2) pressure were recorded. The percent of leakage was calculated. The primary endpoint of this study was the expired tidal volume (V(Texp)). There was a statistically significant difference among the three positions for V(Texp) and PIP values. The OS resulted in higher V(Texp) values when compared with CN (P=0.022). The OS was significantly better than the other two positions, resulting in lower PIP values (P<0.001 and P=0.004, for CN and CS, respectively). The OS also resulted in less leakage during facemask ventilation when compared with CN and CS. Sniffing position combined with mouth opening improves V(Texp) and PIP values during facemask ventilation during sevoflurane-N(2)O anesthesia in paralyzed pediatric patients with adenotonsillar hypertrophy.

  18. Effective field theory of integrating out sfermions in the MSSM: Complete one-loop analysis

    NASA Astrophysics Data System (ADS)

    Huo, Ran

    2018-04-01

    We apply the covariant derivative expansion of the Coleman-Weinberg potential to the sfermion sector in the minimal supersymmetric standard model, matching it to the relevant dimension-6 operators in the standard model effective field theory at one-loop level. Emphasis is paid to nondegenerate large soft supersymmetry breaking mass squares, and the most general analytical Wilson coefficients are obtained for all pure bosonic dimension-6 operators. In addition to the non-logarithmic contributions, they generally have another logarithmic contributions. Various numerical results are shown, in particular the constraints in the large Xt branch reproducing the 125 GeV Higgs mass can be pushed to high values to almost completely probe the low stop mass region at the future FCC-ee experiment, even given the Higgs mass calculation uncertainty.

  19. The range and valence of a real Smirnov function

    NASA Astrophysics Data System (ADS)

    Ferguson, Timothy; Ross, William T.

    2018-02-01

    We give a complete description of the possible ranges of real Smirnov functions (quotients of two bounded analytic functions on the open unit disk where the denominator is outer and such that the radial boundary values are real almost everywhere on the unit circle). Our techniques use the theory of unbounded symmetric Toeplitz operators, some general theory of unbounded symmetric operators, classical Hardy spaces, and an application of the uniformization theorem. In addition, we completely characterize the possible valences for these real Smirnov functions when the valence is finite. To do so we construct Riemann surfaces we call disk trees by welding together copies of the unit disk and its complement in the Riemann sphere. We also make use of certain trees we call valence trees that mirror the structure of disk trees.

  20. Keep your eyes open: dispositional vigilance moderates the relationship between operational police stress and stress symptoms.

    PubMed

    Kubiak, Jeanette; Krick, Annika; Egloff, Boris

    2017-09-01

    Vigilant coping is characterized by a deep processing of threat-related information. In many cases, vigilant coping increases stress symptoms, whereas avoidant coping decreases negative affect. However, vigilance may be beneficial when stress-eliciting situations involve a risk of injury or escalation as is usually the case in police operations. We investigated the roles of vigilance and cognitive avoidance in police operations in a cross-sectional survey. The participants were 137 students (104 men, M age  = 28.54, SD = 8.04) from the Federal University of Applied Administrative Sciences; 76 of them were already police officers (work experience: M = 12.59 years), and 61 were police officer candidates who had completed a 3- to 6-month police internship. Participants completed a paper-and-pencil survey and reported their operational stress, dispositional vigilance and cognitive avoidance in police operations, and stress symptoms. We found that vigilance was negatively associated with stress symptoms and moderated the relationship between operational stress and stress symptoms. Cognitive avoidance, on the other hand, just missed the level of statistical significance in our test of whether it was positively associated with stress symptoms. Our findings demonstrate that vigilance may protect against the negative consequences of stress in police operations.

  1. Outcome following sentinel lymph node biopsy-guided decisions in breast cancer patients with conversion from positive to negative axillary lymph nodes after neoadjuvant chemotherapy.

    PubMed

    Kang, Young-Joon; Han, Wonshik; Park, Soojin; You, Ji Young; Yi, Ha Woo; Park, Sungmin; Nam, Sanggeun; Kim, Joo Heung; Yun, Keong Won; Kim, Hee Jeong; Ahn, Sei Hyun; Park, Seho; Lee, Jeong Eon; Lee, Eun Sook; Noh, Dong-Young; Lee, Jong Won

    2017-11-01

    Many breast cancer patients with positive axillary lymph nodes achieve complete node remission after neoadjuvant chemotherapy. The usefulness of sentinel lymph node biopsy in this situation is uncertain. This study evaluated the outcomes of sentinel biopsy-guided decisions in patients who had conversion of axillary nodes from clinically positive to negative following neoadjuvant chemotherapy. We reviewed the records of 1247 patients from five hospitals in Korea who had breast cancer with clinically axillary lymph node-positive status and negative conversion after neoadjuvant chemotherapy, between 2005 and 2012. Patients who underwent axillary operations with sentinel biopsy-guided decisions (Group A) were compared with patients who underwent complete axillary lymph node dissection without sentinel lymph node biopsy (Group B). Axillary node recurrence and distant recurrence-free survival were compared. There were 428 cases in Group A and 819 in Group B. Kaplan-Meier analysis showed that recurrence-free survivals were not significantly different between Groups A and B (4-year axillary recurrence-free survival: 97.8 vs. 99.0%; p = 0.148). Multivariate analysis also indicated the two groups had no significant difference in axillary and distant recurrence-free survival. For breast cancer patients who had clinical conversion of axillary lymph nodes from positive to negative following neoadjuvant chemotherapy, sentinel biopsy-guided axillary surgery, and axillary lymph node dissection without sentinel lymph node biopsy had similar rates of recurrence. Thus, sentinel biopsy-guided axillary operation in breast cancer patients who have clinically axillary lymph node positive to negative conversion following neoadjuvant chemotherapy is a useful strategy.

  2. Predictive model of outcome of targeted nodal assessment in colorectal cancer.

    PubMed

    Nissan, Aviram; Protic, Mladjan; Bilchik, Anton; Eberhardt, John; Peoples, George E; Stojadinovic, Alexander

    2010-02-01

    Improvement in staging accuracy is the principal aim of targeted nodal assessment in colorectal carcinoma. Technical factors independently predictive of false negative (FN) sentinel lymph node (SLN) mapping should be identified to facilitate operative decision making. To define independent predictors of FN SLN mapping and to develop a predictive model that could support surgical decisions. Data was analyzed from 2 completed prospective clinical trials involving 278 patients with colorectal carcinoma undergoing SLN mapping. Clinical outcome of interest was FN SLN(s), defined as one(s) with no apparent tumor cells in the presence of non-SLN metastases. To assess the independent predictive effect of a covariate for a nominal response (FN SLN), a logistic regression model was constructed and parameters estimated using maximum likelihood. A probabilistic Bayesian model was also trained and cross validated using 10-fold train-and-test sets to predict FN SLN mapping. Area under the curve (AUC) from receiver operating characteristics curves of these predictions was calculated to determine the predictive value of the model. Number of SLNs (<3; P = 0.03) and tumor-replaced nodes (P < 0.01) independently predicted FN SLN. Cross validation of the model created with Bayesian Network Analysis effectively predicted FN SLN (area under the curve = 0.84-0.86). The positive and negative predictive values of the model are 83% and 97%, respectively. This study supports a minimum threshold of 3 nodes for targeted nodal assessment in colorectal cancer, and establishes sufficient basis to conclude that SLN mapping and biopsy cannot be justified in the presence of clinically apparent tumor-replaced nodes.

  3. Laparoscopy-assisted sigmoid resection.

    PubMed

    Fowler, D L; White, S A

    1991-09-01

    Laparoscopic cholecystectomy has been widely accepted, and because of its many benefits, other intra-abdominal operations are now being done laparoscopically. We felt the next step in the evolution of laparoscopic surgery could be bowel resection. This paper presents two cases of laparoscopic sigmoid resection and a detailed description of the technique. Included in the technique is the use of prototype endoscopic stapling devices to divide the mesentery and bowel. The two most difficult technical decisions involved the methods for specimen removal and for completing the anastomosis. The specimen was removed through a muscle splitting incision in the left lower quadrant, positioned as a mirror image of a standard appendectomy incision. The anvil of the CEEA (end-to-end) stapler was also position in the proximal colon through this incision; the anastomosis was completed with the CEEA stapler.

  4. Occupational exposure assessment of magnetic fields generated by induction heating equipment-the role of spatial averaging.

    PubMed

    Kos, Bor; Valič, Blaž; Kotnik, Tadej; Gajšek, Peter

    2012-10-07

    Induction heating equipment is a source of strong and nonhomogeneous magnetic fields, which can exceed occupational reference levels. We investigated a case of an induction tempering tunnel furnace. Measurements of the emitted magnetic flux density (B) were performed during its operation and used to validate a numerical model of the furnace. This model was used to compute the values of B and the induced in situ electric field (E) for 15 different body positions relative to the source. For each body position, the computed B values were used to determine their maximum and average values, using six spatial averaging schemes (9-285 averaging points) and two averaging algorithms (arithmetic mean and quadratic mean). Maximum and average B values were compared to the ICNIRP reference level, and E values to the ICNIRP basic restriction. Our results show that in nonhomogeneous fields, the maximum B is an overly conservative predictor of overexposure, as it yields many false positives. The average B yielded fewer false positives, but as the number of averaging points increased, false negatives emerged. The most reliable averaging schemes were obtained for averaging over the torso with quadratic averaging, with no false negatives even for the maximum number of averaging points investigated.

  5. Comparison between presepsin and procalcitonin in early diagnosis of neonatal sepsis.

    PubMed

    Iskandar, Agustin; Arthamin, Maimun Z; Indriana, Kristin; Anshory, Muhammad; Hur, Mina; Di Somma, Salvatore

    2018-05-09

    Neonatal sepsis remains worldwide one of the leading causes of morbidity and mortality in both term and preterm infants. Lower mortality rates are related to timely diagnostic evaluation and prompt initiation of empiric antibiotic therapy. Blood culture, as gold standard examination for sepsis, has several limitations for early diagnosis, so that sepsis biomarkers could play an important role in this regard. This study was aimed to compare the value of the two biomarkers presepsin and procalcitonin in early diagnosis of neonatal sepsis. This was a prospective cross-sectional study performed, in Saiful Anwar General Hospital Malang, Indonesia, in 51 neonates that fulfill the criteria of systemic inflammatory response syndrome (SIRS) with blood culture as diagnostic gold standard for sepsis. At reviewer operating characteristic (ROC) curve analyses, using a presepsin cutoff of 706,5 pg/mL, the obtained area under the curve (AUCs) were: sensitivity = 85.7%, specificity = 68.8%, positive predictive value = 85.7%, negative predictive value = 68.8%, positive likelihood ratio = 2.75, negative likelihood ratio = 0.21, and accuracy = 80.4%. On the other hand, with a procalcitonin cutoff value of 161.33 pg/mL the obtained AUCs showed: sensitivity = 68.6%, specificity = 62.5%, positive predictive value = 80%, negative predictive value = 47.6%, positive likelihood ratio = 1.83, the odds ratio negative = 0.5, and accuracy = 66.7%. In early diagnosis of neonatal sepsis, compared with procalcitonin, presepsin seems to provide better early diagnostic value with consequent possible faster therapeutical decision making and possible positive impact on outcome of neonates.

  6. [Exposure to whole-body vibration of forklift truck operators in dockyards--actual exposure in Japan and evaluation by EN 13059].

    PubMed

    Tsujimura, Hiroji; Taoda, Kazushi; Nishiyama, Katsuo

    2006-09-01

    Low-back disorders are well documented as occupational hazards among forklift truck operators. The potential risk factors that may lead to low-back pain include exposure to whole-body vibration (WBV). In Europe, test methods were developed to evaluate WBV in industrial trucks, and the European Standard which defines the methods has been published. We measured the vibrations of forklift trucks operated in the Hanshin harbour area adopting procedures based on the CEN test and report the evaluation results. If the WBV magnitudes of the ride on forklift trucks in the workplace were less than or comparable to those in the CEN test, the CEN test could be considered useful for the risk assessment of forklift truck operators exposed to WBV. In order to verify the applicability of the CEN test to the evaluation of WBV exposure in the field, we conducted measurements of the WBV of four forklift trucks for 19 d. The trucks had already been examined by the CEN test. The truck velocity, driver position (sitting or not), and gear lever position were also measured, and video footage was obtained for the study. The results indicate that the vertical WBV magnitudes of the four forklift trucks were below the CEN test values. No dominant WBV direction was observed on any of the measurement days. The Health value (obtained by combining the values determined from the vibration in orthogonal coordinates) was comparable to that from the CEN test for one truck. The values for the other three trucks were lower. The data obtained for three forklift trucks were analyzed in each operating condition. The vertical WBV magnitudes and Health values for the three trucks were below the CEN test values when the trucks were travelling forwards with a load. The WBV in the anterior-posterior direction had the largest adverse effect on the human body of the three orthogonal directions when the trucks were used for loading and unloading. The results suggest the CEN test can be applied to the evaluation of exposure to WBV from forklift trucks operating in the vicinity of the Hanshin harbour. It was observed that the anterior-posterior WBV is considerable, mostly through exposure occurring in the lifting mode. However, the CEN test is based on the travelling mode, and further WBV measurements under real working conditions with exact descriptions of detailed work situations and operating conditions are required.

  7. Clinical values of AFP, GPC3 mRNA in peripheral blood for prediction of hepatocellular carcinoma recurrence following OLT: AFP, GPC3 mRNA for prediction of HCC.

    PubMed

    Wang, Yuliang; Shen, Zhongyang; Zhu, Zhijun; Han, Ruifa; Huai, Mingsheng

    2011-03-01

    Hepatocellular carcinoma (HCC) is one of the most common malignancies worldwide. Annually, about 200,000 patients died of HCC in China. Liver transplantation (LT) holds great theoretical appeal in treating HCC. However, the high recurrence rate after transplantation is the most important limiting factor for long-term survival. To assess the value of alpha-fetoprotein (AFP) messenger RNA (mRNA), Glypican-3 (GPC3) mRNA-expressing cells in the peripheral blood (PB) for prediction of HCC recurrence following orthotopic liver transplantation (OLT). 29 patients with HCC who underwent OLT with a minimum clinical follow-up of 12 months were included in this retrospective study. We detected AFP mRNA, GPC3 mRNA-expressing cells in the PB by TaqMan real-time reverse transcriptase-polymerase chain reaction (RT-PCR), pre-, intra- and post-operatively. The early recurrence of patients was evaluated. 8 (28%), 15 (52%), and 9 (31%) patients had AFP mRNA detected pre-, intra-, and post-operatively, respectively. With 12 months of follow-up, HCC recurred in 7 (24%) patients. Univariate analysis revealed that positive pre- and post-operative AFP mRNA, TNM stage as well as vascular invasion were significant predictors for the HCC recurrence. Multivariate analysis revealed that being positive for AFP mRNA pre-operatively remained a significant risk factor for HCC recurrence after OLT. GPC3 mRNA was expressed in all PB samples. There was no significant difference in the expression levels of GPC3 mRNA between the HCC and control groups. There were no significant differences in GPC3 mRNA expression values between those patients with and without tumor recurrence. The pre-operative detection of circulating AFP mRNA-expressing cells could be a useful predictor for HCC recurrence following OLT. GPC3 mRNA-expressing cells in PB seem to have no diagnostic value.

  8. A double-blinded, prospective study to define antigenemia and quantitative real-time polymerase chain reaction cutoffs to start preemptive therapy in low-risk, seropositive, renal transplanted recipients.

    PubMed

    David-Neto, Elias; Triboni, Ana H K; Paula, Flavio J; Vilas Boas, Lucy S; Machado, Clarisse M; Agena, Fabiana; Latif, Acram Z A; Alencar, Cecília S; Pierrotti, Ligia C; Nahas, William C; Caiaffa-Filho, Helio H; Pannuti, Claudio S

    2014-11-27

    Cytomegalovirus (CMV) disease occurs in 16% to 20% of low-risk, CMV-positive renal transplant recipients. The cutoffs for quantitative real-time polymerase chain reaction (qPCR) or phosphoprotein (pp65) antigenemia (pp65emia) for starting preemptive therapy have not been well established. We measured qPCR and pp65emia weekly from day 7 to day 120 after transplantation, in anti-CMV immunoglobulin G–positive donor and recipient pairs. Patients and physicians were blinded to the test results. Suspicion of CMV disease led to the order of new tests. In asymptomatic viremic patients, the highest pp65emia and qPCR values were used, whereas we considered the last value before diagnosis in those with CMV disease. We collected a total of 1,481 blood samples from 102 adult patients. Seventeen patients developed CMV disease, 54 presented at least one episode of viremia that cleared spontaneously, and 31 never presented viremia. Five patients developed CMV disease after the end of the study period. The median (95% confidence interval) pp65emia and qPCR values were higher before CMV disease than during asymptomatic viremia (6 [9–82] vs. 3 [1–14] cells/10(6) cells; P<0.001 and 3,080 [1,263–15,605] vs. 258 [258–1,679] copies/mL; P=0.008, respectively). The receiver operating characteristic curve showed that pp65emia 4 cells/10(6) cells or greater showed a sensitivity and specificity to predict CMV disease of 69% and 81%, respectively (area, 0.769; P=0.001), with a positive predictive value of 37% and a negative predictive value of 93%. For qPCR 2,000 copies/mL or higher, the positive predictive value and negative predictive value were 57% and 91%, respectively (receiver operating characteristic area, 0.782; P=0.000). With these cutoffs, both methods are appropriate for detecting CMV disease.

  9. Accuracy of a digital impression system based on parallel confocal laser technology for implants with consideration of operator experience and implant angulation and depth.

    PubMed

    Giménez, Beatriz; Özcan, Mutlu; Martínez-Rus, Francisco; Pradíes, Guillermo

    2014-01-01

    To evaluate the accuracy of a digital impression system based on parallel confocal red laser technology, taking into consideration clinical parameters such as operator experience and angulation and depth of implants. A maxillary master model with six implants (located bilaterally in the second molar, second premolar, and lateral incisor positions) was fitted with six polyether ether ketone scan bodies. One second premolar implant was placed with 30 degrees of mesial angulation; the opposite implant was positioned with 30 degrees of distal angulation. The lateral incisor implants were placed 2 or 4 mm subgingivally. Two experienced and two inexperienced operators performed intraoral scanning. Five different interimplant distances were then measured. The files obtained from the scans were imported with reverse-engineering software. Measurements were then made with a coordinate measurement machine, with values from the master model used as reference values. The deviations from the actual values were then calculated. The differences between experienced and inexperienced operators and the effects of different implant angulations and depths were compared statistically. Overall, operator 3 obtained significantly less accurate results. The angulated implants did not significantly influence accuracy compared to the parallel implants. Differences were found in the amount of error in the different quadrants. The second scanned quadrant had significantly worse results than the first scanned quadrant. Impressions of the implants placed at the tissue level were less accurate than implants placed 2 and 4 mm subgingivally. The operator affected the accuracy of measurements, but the performance of the operator was not necessarily dependent on experience. Angulated implants did not decrease the accuracy of the digital impression system tested. The scanned distance affected the predictability of the accuracy of the scanner, and the error increased with the increased length of the scanned section.

  10. The learning curve in robotic distal pancreatectomy.

    PubMed

    Napoli, Niccolò; Kauffmann, Emanuele F; Perrone, Vittorio Grazio; Miccoli, Mario; Brozzetti, Stefania; Boggi, Ugo

    2015-09-01

    No data are available on the learning curve in robotic distal pancreatectomy (RADP). The learning curve in RADP was assessed in 55 consecutive patients using the cumulative sum method, based on operative time. Data were extracted from a prospectively maintained database and analyzed retrospectively considering all events occurring within 90 days of surgery. No operation was converted to laparoscopic or open surgery and no patient died. Post-operative complications occurred in 34 patients (61.8%), being of Clavien-Dindo grade I-II in 32 patients (58.1%), including pancreatic fistula in 29 patients (52.7%). No grade C pancreatic fistula occurred. Four patients received blood transfusions (7.2%), three were readmitted (5.4%) and one required repeat surgery (1.8%). Based on the reduction of operative times (421.1 ± 20.5 vs 248.9 ± 9.3 min; p < 0.0001), completion of the learning curve was achieved after ten operations. Operative time of the first 10 operations was associated with a positive slope (0.47 + 1.78* case number; R (2) 0.97; p < 0.0001*), while that of the following 45 procedures showed a negative slope (23.52 - 0.39* case number; R (2) 0.97; p < 0.0001*). After completion of the learning curve, more patients had a malignant histology (0 vs 35.6%; p = 0.002), accounting for both higher lymph node yields (11.1 ± 12.2 vs 20.9 ± 18.5) (p = 0.04) and lower rate of spleen preservation (90 vs 55.6%) (p = 0.04). RADP was safely feasible in selected patients and the learning curve was completed after ten operations. Improvement in clinical outcome was not demonstrated, probably because of the limited occurrence of outcome comparators.

  11. Classicality condition on a system observable in a quantum measurement and a relative-entropy conservation law

    NASA Astrophysics Data System (ADS)

    Kuramochi, Yui; Ueda, Masahito

    2015-03-01

    We consider the information flow on a system observable X corresponding to a positive-operator-valued measure under a quantum measurement process Y described by a completely positive instrument from the viewpoint of the relative entropy. We establish a sufficient condition for the relative-entropy conservation law which states that the average decrease in the relative entropy of the system observable X equals the relative entropy of the measurement outcome of Y , i.e., the information gain due to measurement. This sufficient condition is interpreted as an assumption of classicality in the sense that there exists a sufficient statistic in a joint successive measurement of Y followed by X such that the probability distribution of the statistic coincides with that of a single measurement of X for the premeasurement state. We show that in the case when X is a discrete projection-valued measure and Y is discrete, the classicality condition is equivalent to the relative-entropy conservation for arbitrary states. The general theory on the relative-entropy conservation is applied to typical quantum measurement models, namely, quantum nondemolition measurement, destructive sharp measurements on two-level systems, a photon counting, a quantum counting, homodyne and heterodyne measurements. These examples except for the nondemolition and photon-counting measurements do not satisfy the known Shannon-entropy conservation law proposed by Ban [M. Ban, J. Phys. A: Math. Gen. 32, 1643 (1999), 10.1088/0305-4470/32/9/012], implying that our approach based on the relative entropy is applicable to a wider class of quantum measurements.

  12. The first full orbit of η Carinae seen by Fermi

    DOE PAGES

    Reitberger, Klaus; Reimer, A.; Reimer, O.; ...

    2015-05-08

    The binary system η Carinae has completed its first 5.54 y orbit since the beginning of science operation of the Fermi Large Area Telescope (LAT). We are now able to investigate the high-energy γ-ray source at the position of η Carinae over its full orbital period. By this, we can address and confirm earlier predictions for temporal and spectral variability. Here, newer versions of the LAT datasets, instrument response functions and background models allow for a more accurate analysis. Therefore it is important to re-evaluate the previously analyzed time period along with the new data to further constrain location, spectralmore » shape, and flux time history of the γ-ray source. As a result, we confirm earlier predictions of increasing flux values above 10 GeV toward the next periastron passage. For the most recent part of the data sample, flux values as high as those before the first periastron passage in 2008 are recorded. A comparison of spectral energy distributions around periastron and apastron passages reveals strong variation in the high-energy band. This is due to a second spectral component that is present only around periastron. In conclusion, improved spatial consistency with the γ-ray source at the position of η Carinae along with the confirmation of temporal variability above 10 GeV in conjunction with the orbital period strengthens the argument for unambiguous source identification. Spectral variability provides additional constraints for future modeling of the particle acceleration and γ-ray emission in colliding-wind binary systems.« less

  13. Naval Classical Thinkers and Operational Art

    DTIC Science & Technology

    2009-01-01

    Principles and Practice of Military Operations on Land, published in 1911, did not attract as much attention as his previous two major works...thinker. He failed, for example, to consider factors such as social and cultural conditions in the rise of sea power; the rise of the English middle...three key ideas: the inherent value of a strategic central or interior position, the principle of concentration, and the close relationship between

  14. Development of a supervisory skills course for hospital pharmacy workplaces.

    PubMed

    Woloschuk, Donna M M; Raymond, Colette B

    2010-07-01

    Many Canadian hospital pharmacies are experiencing difficulties recruiting supervisory personnel. It was expected that, through a "learning-by-doing" course, pharmacy staff would learn to apply basic skills in the day-to-day supervision of pharmacy operations and human resources and to apply the principles of supervisory documentation. A supervisory skills course targeted to pharmacy staff members was developed and implemented by the pharmacy department of a large urban health region. The course was initially offered to practising pharmacy technicians. The course design emphasized a constructivist framework incorporating authentic learning and reflective practice during seminars, with experiential and self-directed learning in the workplace. Preceptors assisted learners to achieve the course goals. Learners and preceptors provided feedback about hours spent (as the course progressed) and about their satisfaction with the course itself (at the end of the course). Learners and preceptors completed a post-program evaluation 2 months after completing the course to help in the assessment of the transfer of learning (lasting impact) associated with the course. Overall performance in the course was assessed on a pass/fail basis. Eighteen pharmacy technicians were admitted to the program, but one withdrew because of a job change. All learners successfully completed the course. Two months after the course, learners and preceptors described enhanced organization, time management, leadership, communication, and conflict-resolution skills on the part of learners, as well as their increased confidence, maturity, and ability to supervise staff. Learners' evaluations revealed a broadened perspective of pharmacy. The preceptors valued the enhancement of learners' skills and their increased enthusiasm. At the time of writing, 6 of the participants had secured supervisory positions. Creating formal instruction that engages pharmacy staff to pursue management positions is challenging. Instructional design grounded in constructivist theory and incorporating authentic learning experiences and reflection resulted in high learner satisfaction with learning outcomes.

  15. Development of a Supervisory Skills Course for Hospital Pharmacy Workplaces

    PubMed Central

    Woloschuk, Donna M M; Raymond, Colette B

    2010-01-01

    Background and Objective: Many Canadian hospital pharmacies are experiencing difficulties recruiting supervisory personnel. It was expected that, through a “learning-by-doing” course, pharmacy staff would learn to apply basic skills in the day-to-day supervision of pharmacy operations and human resources and to apply the principles of supervisory documentation. Methods: A supervisory skills course targeted to pharmacy staff members was developed and implemented by the pharmacy department of a large urban health region. The course was initially offered to practising pharmacy technicians. The course design emphasized a constructivist framework incorporating authentic learning and reflective practice during seminars, with experiential and self-directed learning in the workplace. Preceptors assisted learners to achieve the course goals. Learners and preceptors provided feedback about hours spent (as the course progressed) and about their satisfaction with the course itself (at the end of the course). Learners and preceptors completed a post-program evaluation 2 months after completing the course to help in the assessment of the transfer of learning (lasting impact) associated with the course. Overall performance in the course was assessed on a pass/fail basis. Results: Eighteen pharmacy technicians were admitted to the program, but one withdrew because of a job change. All learners successfully completed the course. Two months after the course, learners and preceptors described enhanced organization, time management, leadership, communication, and conflict-resolution skills on the part of learners, as well as their increased confidence, maturity, and ability to supervise staff. Learners’ evaluations revealed a broadened perspective of pharmacy. The preceptors valued the enhancement of learners’ skills and their increased enthusiasm. At the time of writing, 6 of the participants had secured supervisory positions. Conclusion: Creating formal instruction that engages pharmacy staff to pursue management positions is challenging. Instructional design grounded in constructivist theory and incorporating authentic learning experiences and reflection resulted in high learner satisfaction with learning outcomes. PMID:22478992

  16. Role of imprint cytology in intra operative diagnosis of thyroid lesions.

    PubMed

    Anila, K R; Krishna, G

    2014-07-01

    Intra-operative imprint cytology is an important diagnostic modality in the diagnosis of thyroid lesions. A correct intra-operative diagnosis helps eliminate the need for second surgery. To study diagnostic accuracy of imprint cytology and to compare the imprint cytology results with that of the corresponding paraffin section diagnosis in thyroidectomy cases. This is a prospective study of 84 patients who have undergone thyroidectomies over a period of one year at the Department of Surgery, Thiruvananthapuram, Kerala, India. The intraoperative imprint cytology smears were stained by Papanicolaou method. The imprint cytology interpretation was later compared with the paraffin section diagnosis. Of the 84 patients using haematoxylin and eosin stained histopathology sections as the gold standard, the diagnostic sensitivity of imprint cytology was 75% and specificity was 100%. Positive predictive value was 100%. Negative predictive value was 98.74%. Imprint cytology has high sensitivity and specificity in diagnosing lesions of the thyroid. The problems faced were in diagnosing follicular carcinomas and differentiating low grade lymphoma from lymphocytic thyroiditis. Imprint cytology is a simple, reliable diagnostic technique. It has high sensitivity and specificity in intra-operative diagnosis of lesions of thyroid. In spite of the advent of newer diagnostic modalities like frozen sections, imprint cytology still holds its unique position in the current perspective.

  17. Promoting Independence through Assistive Technology: Evaluating Audio Recorders to Support Grocery Shopping

    ERIC Educational Resources Information Center

    Bouck, Emily C.; Satsangi, Rajiv; Bartlett, Whitney; Weng, Pei-Lin

    2012-01-01

    In light of a positive research base regarding technology-based self-operating prompting systems (e.g., iPods), yet a concern about the sustainability of such technologies after a research project is completed, this study sought to explore the effectiveness and efficiency of an audio recorder, a low-cost, more commonly accessible technology to…

  18. Noninvasive prediction of shunt operation outcome in idiopathic normal pressure hydrocephalus

    PubMed Central

    Aoki, Yasunori; Kazui, Hiroaki; Tanaka, Toshihisa; Ishii, Ryouhei; Wada, Tamiki; Ikeda, Shunichiro; Hata, Masahiro; Canuet, Leonides; Katsimichas, Themistoklis; Musha, Toshimitsu; Matsuzaki, Haruyasu; Imajo, Kaoru; Kanemoto, Hideki; Yoshida, Tetsuhiko; Nomura, Keiko; Yoshiyama, Kenji; Iwase, Masao; Takeda, Masatoshi

    2015-01-01

    Idiopathic normal pressure hydrocephalus (iNPH) is a syndrome characterized by gait disturbance, cognitive deterioration and urinary incontinence in elderly individuals. These symptoms can be improved by shunt operation in some but not all patients. Therefore, discovering predictive factors for the surgical outcome is of great clinical importance. We used normalized power variance (NPV) of electroencephalography (EEG) waves, a sensitive measure of the instability of cortical electrical activity, and found significantly higher NPV in beta frequency band at the right fronto-temporo-occipital electrodes (Fp2, T4 and O2) in shunt responders compared to non-responders. By utilizing these differences, we were able to correctly identify responders and non-responders to shunt operation with a positive predictive value of 80% and a negative predictive value of 88%. Our findings indicate that NPV can be useful in noninvasively predicting the clinical outcome of shunt operation in patients with iNPH. PMID:25585705

  19. Minimizing distortion and internal forces in truss structures by simulated annealing

    NASA Technical Reports Server (NTRS)

    Kincaid, Rex K.

    1989-01-01

    Inaccuracies in the length of members and the diameters of joints of large truss reflector backup structures may produce unacceptable levels of surface distortion and member forces. However, if the member lengths and joint diameters can be measured accurately it is possible to configure the members and joints so that root-mean-square (rms) surface error and/or rms member forces is minimized. Following Greene and Haftka (1989) it is assumed that the force vector f is linearly proportional to the member length errors e(sub M) of dimension NMEMB (the number of members) and joint errors e(sub J) of dimension NJOINT (the number of joints), and that the best-fit displacement vector d is a linear function of f. Let NNODES denote the number of positions on the surface of the truss where error influences are measured. The solution of the problem is discussed. To classify, this problem was compared to a similar combinatorial optimization problem. In particular, when only the member length errors are considered, minimizing d(sup 2)(sub rms) is equivalent to the quadratic assignment problem. The quadratic assignment problem is a well known NP-complete problem in operations research literature. Hence minimizing d(sup 2)(sub rms) is is also an NP-complete problem. The focus of the research is the development of a simulated annealing algorithm to reduce d(sup 2)(sub rms). The plausibility of this technique is its recent success on a variety of NP-complete combinatorial optimization problems including the quadratic assignment problem. A physical analogy for simulated annealing is the way liquids freeze and crystallize. All computational experiments were done on a MicroVAX. The two interchange heuristic is very fast but produces widely varying results. The two and three interchange heuristic provides less variability in the final objective function values but runs much more slowly. Simulated annealing produced the best objective function values for every starting configuration and was faster than the two and three interchange heuristic.

  20. Induced simplified neutrosophic correlated aggregation operators for multi-criteria group decision-making

    NASA Astrophysics Data System (ADS)

    Şahin, Rıdvan; Zhang, Hong-yu

    2018-03-01

    Induced Choquet integral is a powerful tool to deal with imprecise or uncertain nature. This study proposes a combination process of the induced Choquet integral and neutrosophic information. We first give the operational properties of simplified neutrosophic numbers (SNNs). Then, we develop some new information aggregation operators, including an induced simplified neutrosophic correlated averaging (I-SNCA) operator and an induced simplified neutrosophic correlated geometric (I-SNCG) operator. These operators not only consider the importance of elements or their ordered positions, but also take into account the interactions phenomena among decision criteria or their ordered positions under multiple decision-makers. Moreover, we present a detailed analysis of I-SNCA and I-SNCG operators, including the properties of idempotency, commutativity and monotonicity, and study the relationships among the proposed operators and existing simplified neutrosophic aggregation operators. In order to handle the multi-criteria group decision-making (MCGDM) situations where the weights of criteria and decision-makers usually correlative and the criterion values are considered as SNNs, an approach is established based on I-SNCA operator. Finally, a numerical example is presented to demonstrate the proposed approach and to verify its effectiveness and practicality.

  1. Dexterous programmable robot and control system

    NASA Astrophysics Data System (ADS)

    Engler, Charles D., Jr.

    1995-09-01

    An anatomically correct, humanlike, mechanical arm and hand is provided that an operator can control to perform with the dexterity and compliance of a human hand. Being humanlike and robotic enhances the device's control and gripper dexterity. Control of the movement of the arm and hand is performed or guided by a 'teach glove' worn by the operator. As he or she performs some hand manipulation, a controller stores signals from sensors on the exoskeleton. The sensors monitor the operator's finger-joint movement positions. These values are later translated into actuator control signals for servomotors, eventually duplicating the operator's movement.

  2. Commissioning and quality assurance of an integrated system for patient positioning and setup verification in particle therapy.

    PubMed

    Pella, A; Riboldi, M; Tagaste, B; Bianculli, D; Desplanques, M; Fontana, G; Cerveri, P; Seregni, M; Fattori, G; Orecchia, R; Baroni, G

    2014-08-01

    In an increasing number of clinical indications, radiotherapy with accelerated particles shows relevant advantages when compared with high energy X-ray irradiation. However, due to the finite range of ions, particle therapy can be severely compromised by setup errors and geometric uncertainties. The purpose of this work is to describe the commissioning and the design of the quality assurance procedures for patient positioning and setup verification systems at the Italian National Center for Oncological Hadrontherapy (CNAO). The accuracy of systems installed in CNAO and devoted to patient positioning and setup verification have been assessed using a laser tracking device. The accuracy in calibration and image based setup verification relying on in room X-ray imaging system was also quantified. Quality assurance tests to check the integration among all patient setup systems were designed, and records of daily QA tests since the start of clinical operation (2011) are presented. The overall accuracy of the patient positioning system and the patient verification system motion was proved to be below 0.5 mm under all the examined conditions, with median values below the 0.3 mm threshold. Image based registration in phantom studies exhibited sub-millimetric accuracy in setup verification at both cranial and extra-cranial sites. The calibration residuals of the OTS were found consistent with the expectations, with peak values below 0.3 mm. Quality assurance tests, daily performed before clinical operation, confirm adequate integration and sub-millimetric setup accuracy. Robotic patient positioning was successfully integrated with optical tracking and stereoscopic X-ray verification for patient setup in particle therapy. Sub-millimetric setup accuracy was achieved and consistently verified in daily clinical operation.

  3. Precision Joining Center

    NASA Astrophysics Data System (ADS)

    Powell, J. W.; Westphal, D. A.

    1991-08-01

    A workshop to obtain input from industry on the establishment of the Precision Joining Center (PJC) was held on July 10-12, 1991. The PJC is a center for training Joining Technologists in advanced joining techniques and concepts in order to promote the competitiveness of U.S. industry. The center will be established as part of the DOE Defense Programs Technology Commercialization Initiative, and operated by EG&G Rocky Flats in cooperation with the American Welding Society and the Colorado School of Mines Center for Welding and Joining Research. The overall objectives of the workshop were to validate the need for a Joining Technologists to fill the gap between the welding operator and the welding engineer, and to assure that the PJC will train individuals to satisfy that need. The consensus of the workshop participants was that the Joining Technologist is a necessary position in industry, and is currently used, with some variation, by many companies. It was agreed that the PJC core curriculum, as presented, would produce a Joining Technologist of value to industries that use precision joining techniques. The advantage of the PJC would be to train the Joining Technologist much more quickly and more completely. The proposed emphasis of the PJC curriculum on equipment intensive and hands-on training was judged to be essential.

  4. An investigation of new toxicity test method performance in validation studies: 1. Toxicity test methods that have predictive capacity no greater than chance.

    PubMed

    Bruner, L H; Carr, G J; Harbell, J W; Curren, R D

    2002-06-01

    An approach commonly used to measure new toxicity test method (NTM) performance in validation studies is to divide toxicity results into positive and negative classifications, and the identify true positive (TP), true negative (TN), false positive (FP) and false negative (FN) results. After this step is completed, the contingent probability statistics (CPS), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) are calculated. Although these statistics are widely used and often the only statistics used to assess the performance of toxicity test methods, there is little specific guidance in the validation literature on what values for these statistics indicate adequate performance. The purpose of this study was to begin developing data-based answers to this question by characterizing the CPS obtained from an NTM whose data have a completely random association with a reference test method (RTM). Determining the CPS of this worst-case scenario is useful because it provides a lower baseline from which the performance of an NTM can be judged in future validation studies. It also provides an indication of relationships in the CPS that help identify random or near-random relationships in the data. The results from this study of randomly associated tests show that the values obtained for the statistics vary significantly depending on the cut-offs chosen, that high values can be obtained for individual statistics, and that the different measures cannot be considered independently when evaluating the performance of an NTM. When the association between results of an NTM and RTM is random the sum of the complementary pairs of statistics (sensitivity + specificity, NPV + PPV) is approximately 1, and the prevalence (i.e., the proportion of toxic chemicals in the population of chemicals) and PPV are equal. Given that combinations of high sensitivity-low specificity or low specificity-high sensitivity (i.e., the sum of the sensitivity and specificity equal to approximately 1) indicate lack of predictive capacity, an NTM having these performance characteristics should be considered no better for predicting toxicity than by chance alone.

  5. AFLOW-SYM: platform for the complete, automatic and self-consistent symmetry analysis of crystals.

    PubMed

    Hicks, David; Oses, Corey; Gossett, Eric; Gomez, Geena; Taylor, Richard H; Toher, Cormac; Mehl, Michael J; Levy, Ohad; Curtarolo, Stefano

    2018-05-01

    Determination of the symmetry profile of structures is a persistent challenge in materials science. Results often vary amongst standard packages, hindering autonomous materials development by requiring continuous user attention and educated guesses. This article presents a robust procedure for evaluating the complete suite of symmetry properties, featuring various representations for the point, factor and space groups, site symmetries and Wyckoff positions. The protocol determines a system-specific mapping tolerance that yields symmetry operations entirely commensurate with fundamental crystallographic principles. The self-consistent tolerance characterizes the effective spatial resolution of the reported atomic positions. The approach is compared with the most used programs and is successfully validated against the space-group information provided for over 54 000 entries in the Inorganic Crystal Structure Database (ICSD). Subsequently, a complete symmetry analysis is applied to all 1.7+ million entries of the AFLOW data repository. The AFLOW-SYM package has been implemented in, and made available for, public use through the automated ab initio framework AFLOW.

  6. Trace Elements and Oxygen Isotope Zoning of the Sidewinder Skarn

    NASA Astrophysics Data System (ADS)

    Draper, C.; Gevedon, M. L.; Barnes, J.; Lackey, J. S.; Jiang, H.; Lee, C. T.

    2016-12-01

    Skarns of the Verde Antique Quarry and White Horse Mountain areas of the Sidewinder Range give insight into the paleohydrothermal systems operating in the California's Jurassic arc in the Southwestern Mojave Desert. Garnet from these skarns is iron rich: Xand= 55-100. Laser fluorination measurements show oxygen isotope (δ18O) compositions of garnet crystals and crystals domains have large ranges: -3.1‰ to +4.4‰ and -8.9‰ to +3.4‰, respectively. In general, the garnet cores have more negative δ18O values than rims, although oscillations are present. Negative values have been interpreted as influx of meteoric fluid and positive values as increased magmatic input. Here we report major and trace element concentrations for 17 core to rim Sidewinder garnet transects. REEs concentrations are low in all crystals, with total REE concentrations ranging from 0.710 ppm to 33.7 ppm, values that are lower than Cretaceous skarn garnets in the Sierra Nevada in the White Chief and Empire Mt skarns. Such low concentrations are likely due to the higher fraction of meteoric fluids during formation of the Sidewinder skarns. REE concentrations decrease from core to rim (REE core average=12.2ppm, REE rim average=7.21ppm). This is slightly more pronounced in the LREEs than in the HREEs (LaN/YbN core average= 10.9; rim average= 9.73, normalized to Chondrite). X­and tends to decrease core to rim in the Verde Antique skarn, whereas, Xand of the White Horse skarn does not correlate with distance from core. A large positive Eu anomaly (Eu/Eu* = 3­-30) in garnet from both skarns suggests oxidizing fluid conditions. Oxygen isotope data from garnet in these same skarns show periods of time with increased proportion of magmatic derived fluids in the total fluid budget. However, there is no corresponding widespread increase in total REE concentrations. Other studies of skarns from the western Sierra Nevadan arc (White Chief and Empire Mountain) observe complete decoupling of d18O values and trace element compositions. Future modeling should consider modal abundance of fluid soluble minerals in cooling and altering plutons to probe the REE budget.

  7. Values and love styles in Turkey and Great Britain: an intercultural and intracultural comparison.

    PubMed

    Sanrı, Çağla; Goodwin, Robin

    2013-01-01

    Little previous research has examined the relationship between values and love styles, and none has done so across cultures or intracultural regions. This research was the first attempt to explore the correlation between individual-level values and love styles, and examined both within- and between-cultural variations in love styles. In this study 224 participants from Turkey and Britain, from urban or rural locations, completed the Portrait Values Questionnaire and the Love Attitudes Scale measure of love styles. Pancultural analyses demonstrated significant correlations between certain value dimensions and love styles. In particular, agape (selfless love) was positively correlated with self-transcendence, ludus (game-playing love) was positively correlated with self-enhancement, and pragma (realistic love) was positively correlated with conservation. The inclusion of location and nationality and their interactions with values in the multiple regression analyses significantly increased the variance explained by values for five of the six love styles. Multivariate analyses indicated that ludus, storge, mania, and pragma were all significantly higher among Turkish respondents; pragma, mania, and agape all higher amongst rural respondents. Eros was highest among rural British respondents; storge, pragma, and agape highest among rural Turks. When these culture effects were explored, conservation significantly mediated the relationship between the groups of more conservative rural Turks (versus other participants) and both pragmatic and storgic love styles. Findings are discussed in the light of disparities in values and relationship styles within cultures, and the need to include both intracultural and intercultural variations in cross cultural research.

  8. Changing health behaviors to improve health outcomes after angioplasty: a randomized trial of net present value versus future value risk communication.

    PubMed

    Charlson, M E; Peterson, J C; Boutin-Foster, C; Briggs, W M; Ogedegbe, G G; McCulloch, C E; Hollenberg, J; Wong, C; Allegrante, J P

    2008-10-01

    Patients who have undergone angioplasty experience difficulty modifying at-risk behaviors for subsequent cardiac events. The purpose of this study was to test whether an innovative approach to framing of risk, based on 'net present value' economic theory, would be more effective in behavioral intervention than the standard 'future value approach' in reducing cardiovascular morbidity and mortality following angioplasty. At baseline, all patients completed a health assessment, received an individualized risk profile and selected risk factors for modification. The intervention randomized patients into two varying methods for illustrating positive effects of behavior change. For the experimental group, each selected risk factor was assigned a numeric biologic age (the net present value) that approximated the relative potential to improve current health status and quality of life when modifying that risk factor. In the control group, risk reduction was framed as the value of preventing future health problems. Ninety-four percent of patients completed 2-year follow-up. There was no difference between the rates of death, stroke, myocardial infarction, Class II-IV angina or severe ischemia (on non-invasive testing) between the net present value group and the future value group. Our results show that a net present risk communication intervention did not result in significant differences in health outcomes.

  9. Two-axis antenna positioning mechanism

    NASA Technical Reports Server (NTRS)

    Herald, Michelle; Wai, Leilani C.

    1994-01-01

    The two-axis antenna positioning mechanism (TAAPM) is used to position three Ku-band and one C-band spot antennas on the INTELSAT 7 (I-7) spacecraft, which is a commercial telecommunications satellite purchased and operated by INTELSAT, an international consortium. The first I-7 was successfully launched on 22 Oct. 1993 from French Guiana on an Ariane launch vehicle. The TAAPM's on the first I-7 satellite successfully completed their in-orbit functional testing. The TAAPM was an entirely new design for Space Systems/Loral. This paper will describe the spacecraft/system requirements and application of the TAAPM and present the technical findings of TAAPM qualification and protoflight testing.

  10. Noise generated by a propeller in a wake

    NASA Technical Reports Server (NTRS)

    Block, P. J. W.

    1984-01-01

    Propeller performance and noise were measured on two model scale propellers operating in an anechoic flow environment with and without a wake. Wake thickness of one and three propeller chords were generated by an airfoil which spanned the full diameter of the propeller. Noise measurements were made in the relative near field of the propeller at three streamwise and three azimuthal positions. The data show that as much as 10 dB increase in the OASPL results when a wake is introduced into an operating propeller. Performance data are also presented for completeness.

  11. On a Lagrange-Hamilton formalism describing position and momentum uncertainties

    NASA Technical Reports Server (NTRS)

    Schuch, Dieter

    1993-01-01

    According to Heisenberg's uncertainty relation, in quantum mechanics it is not possible to determine, simultaneously, exact values for the position and the momentum of a material system. Calculating the mean value of the Hamiltonian operator with the aid of exact analytic Gaussian wave packet solutions, these uncertainties cause an energy contribution additional to the classical energy of the system. For the harmonic oscillator, e.g., this nonclassical energy represents the ground state energy. It will be shown that this additional energy contribution can be considered as a Hamiltonian function, if it is written in appropriate variables. With the help of the usual Lagrange-Hamilton formalism known from classical particle mechanics, but now considering this new Hamiltonian function, it is possible to obtain the equations of motion for position and momentum uncertainties.

  12. Control method for turbocharged diesel engines having exhaust gas recirculation

    DOEpatents

    Kolmanovsky, Ilya V.; Jankovic, Mrdjan J; Jankovic, Miroslava

    2000-03-14

    A method of controlling the airflow into a compression ignition engine having an EGR and a VGT. The control strategy includes the steps of generating desired EGR and VGT turbine mass flow rates as a function of the desired and measured compressor mass airflow values and exhaust manifold pressure values. The desired compressor mass airflow and exhaust manifold pressure values are generated as a function of the operator-requested fueling rate and engine speed. The EGR and VGT turbine mass flow rates are then inverted to corresponding EGR and VGT actuator positions to achieve the desired compressor mass airflow rate and exhaust manifold pressure. The control strategy also includes a method of estimating the intake manifold pressure used in generating the EGR valve and VGT turbine positions.

  13. The MER Mossbauer Spectrometers: 40 Months of Operation on the Martian Surface

    NASA Technical Reports Server (NTRS)

    Fleischer, Iris; Rodionov, D.; Schroeder, C.; Morris, R.; Yen, A.; Ming, D.; McCoy, T.; Mittlefehldt, D.; Gellert, R.; Cohen, B.; hide

    2007-01-01

    The primary MER objectives have been successfully completed. The total integration time of all MB measurements exceeds the duration of the primary 90-sols-mission for Spirit's MB spectrometer, and approaches this value for Opportunity's MB spectrometer. Both MB spectrometers continue to accumulate valuable scientific data after three years of operation (data is available for download [13]) The identification of aqueous minerals such as goethite in Gusev crater and jarosite at Meridiani Planum by the MER Mossbauer spectrometers is strong evidence for past water activity at the two landing sites.

  14. Invariant measure of the one-loop quantum gravitational backreaction on inflation

    NASA Astrophysics Data System (ADS)

    Miao, S. P.; Tsamis, N. C.; Woodard, R. P.

    2017-06-01

    We use dimensional regularization in pure quantum gravity on a de Sitter background to evaluate the one-loop expectation value of an invariant operator which gives the local expansion rate. We show that the renormalization of this nonlocal composite operator can be accomplished using the counterterms of a simple local theory of gravity plus matter, at least at one-loop order. This renormalization completely absorbs the one-loop correction, which accords with the prediction that the lowest secular backreaction should be a two-loop effect.

  15. TU-FG-201-09: Predicting Accelerator Dysfunction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Able, C; Nguyen, C; Baydush, A

    Purpose: To develop an integrated statistical process control (SPC) framework using digital performance and component data accumulated within the accelerator system that can detect dysfunction prior to unscheduled downtime. Methods: Seven digital accelerators were monitored for twelve to 18 months. The accelerators were operated in a ‘run to failure mode’ with the individual institutions determining when service would be initiated. Institutions were required to submit detailed service reports. Trajectory and text log files resulting from a robust daily VMAT QA delivery were decoded and evaluated using Individual and Moving Range (I/MR) control charts. The SPC evaluation was presented in amore » customized dashboard interface that allows the user to review 525 monitored parameters (480 MLC parameters). Chart limits were calculated using a hybrid technique that includes the standard SPC 3σ limits and an empirical factor based on the parameter/system specification. The individual (I) grand mean values and control limit ranges of the I/MR charts of all accelerators were compared using statistical (ranked analysis of variance (ANOVA)) and graphical analyses to determine consistency of operating parameters. Results: When an alarm or warning was directly connected to field service, process control charts predicted dysfunction consistently on beam generation related parameters (BGP)– RF Driver Voltage, Gun Grid Voltage, and Forward Power (W); beam uniformity parameters – angle and position steering coil currents; and Gantry position accuracy parameter: cross correlation max-value. Control charts for individual MLC – cross correlation max-value/position detected 50% to 60% of MLCs serviced prior to dysfunction or failure. In general, non-random changes were detected 5 to 80 days prior to a service intervention. The ANOVA comparison of BGP determined that each accelerator parameter operated at a distinct value. Conclusion: The SPC framework shows promise. Long term monitoring coordinated with service will be required to definitively determine the effectiveness of the model. Varian Medical System, Inc. provided funding in support of the research presented.« less

  16. Safety by design: effects of operating room floor marking on the position of surgical devices to promote clean air flow compliance and minimise infection risks.

    PubMed

    de Korne, Dirk F; van Wijngaarden, Jeroen D H; van Rooij, Jeroen; Wauben, Linda S G L; Hiddema, U Frans; Klazinga, Niek S

    2012-09-01

    To evaluate the use of floor marking on the positioning of surgical devices within the clean air flow in an operating room (OR) to minimise infection risk. Laminar flow clean air systems are important in preventing infection in ORs but, for optimal results, surgical devices must be correctly positioned. The authors evaluated floor marking in four ORs at an eye hospital using time series analysis. Through observations during 829 surgeries over a 20-month period, the positions of surgical devices were determined. Eight semistructured interviews with surgical staff were conducted to assess user experiences and team dynamics. Before marking, the instrument table was positioned completely within the laminar flow in only 6.1% of the cases. This increased to 36.1% and finally 53.8%. Mayo stands were increasingly positioned within the laminar flow: from 74.2% to 84.7%. The surgical lamp decreasingly obstructed flow: from 41.8% to 28.7%. At T3 (20 months), however, in 48.6% of the applicable cases the lamp was positioned in the flow again. Discussions and site visits between airside operators and surgical staff resulted in increasing awareness of specific risk areas in the OR. OR floor markings facilitated and stimulated safety awareness and resulted in significantly increased compliance with the positioning of surgical devices in the clean air flow. Safety and quality approaches in hospital care, therefore, should include a human factors approach that focuses on system design in addition to teaching clinical and non-technical skills.

  17. Performance characteristics of broth-only cultures after revision total joint arthroplasty.

    PubMed

    Smith, Eric B; Cai, Jenny; Wynne, Rachael; Maltenfort, Mitchell; Good, Robert P

    2014-11-01

    Surgeons frequently obtain intraoperative cultures at the time of revision total joint arthroplasty. The use of broth or liquid medium before applying the sample to the agar medium may be associated with contamination and false-positive cultures; however, the degree to which this is the case is not known. We (1) calculated the performance characteristics of broth-only cultures (sensitivity, specificity, positive predictive value, and negative predictive value) and (2) characterized the organisms identified in broth to determine whether a specific organism showed increased proclivity for true-positive periprosthetic joint infection (PJI). A single-institution retrospective chart review was performed on 257 revision total joint arthroplasties from 2009 through 2010. One hundred ninety (74%) had cultures for review. All culture results, as well as treatment, if any, were documented and patients were followed for a minimum of 1 year for evidence of PJI. Cultures were measured as either positive from the broth only or broth negative. The true diagnosis of infection was determined by the Musculoskeletal Infection Society criteria during the preoperative workup or postoperatively at 1 year for purposes of calculating the performance characteristics of the broth-only culture. The sensitivity, specificity, positive predictive value, and negative predictive value were 19%, 88%, 13%, and 92%, respectively. The most common organism identified was coagulase-negative Staphylococcus (16 of 24 cases, 67%). Coagulase-negative Staphylococcus was present in all three true-positive cases; however, it was also found in 13 of the false-positive cases. The broth-only positive cultures showed poor sensitivity and positive predictive value but good specificity and negative predictive value. The good specificity indicates that it can help to rule in the presence of PJI; however, the poor sensitivity makes broth-only culture an unreliable screening test. We recommend that broth-only culture results be carefully scrutinized and decisions on the diagnosis and treatment of infection should be based specifically on the Musculoskeletal Infection Society criteria. Level IV, diagnostic study. See Instructions for Authors for a complete description of levels of evidence.

  18. On a true value of risk

    NASA Astrophysics Data System (ADS)

    Kozine, Igor

    2018-04-01

    The paper suggests looking on probabilistic risk quantities and concepts through the prism of accepting one of the views: whether a true value of risk exists or not. It is argued that discussions until now have been primarily focused on closely related topics that are different from the topic of the current paper. The paper examines operational consequences of adhering to each of the views and contrasts them. It is demonstrated that operational differences on how and what probabilistic measures can be assessed and how they can be interpreted appear tangible. In particular, this concerns prediction intervals, the use of Byes rule, models of complete ignorance, hierarchical models of uncertainty, assignment of probabilities over possibility space and interpretation of derived probabilistic measures. Behavioural implications of favouring the either view are also briefly described.

  19. Individual values, learning routines and academic procrastination.

    PubMed

    Dietz, Franziska; Hofer, Manfred; Fries, Stefan

    2007-12-01

    Academic procrastination, the tendency to postpone learning activities, is regarded as a consequence of postmodern values that are prominent in post-industrialized societies. When students strive for leisure goals and have no structured routines for academic tasks, delaying strenuous learning activities becomes probable. The model tested in this study posits that postmodern value orientations are positively related to procrastination and to a lack of daily routines concerning the performance of academic activities. In contrast, modern values are negatively related to procrastination and positively to learning routines. Academic procrastination, in-turn, should be associated with the tendency to prefer leisure activities to schoolwork in case of conflicts between these two life domains. Seven hundred and four students from 6th and 8th grade with a mean age of 13.5 years participated in the study. The sample included students from all tracks of the German educational system. Students completed a questionnaire containing two value prototypes as well as scales on learning routines and procrastination. Decisions in motivational conflicts were measured using two vignettes. Results from structural equation modelling supported the proposed model for the whole sample as well as for each school track. A planned course of the day can prevent procrastination and foster decisions for academic tasks in case of conflicts. Students' learning takes place within a societal context and reflects the values held in the respective culture.

  20. Improving the Quality of Oral and Maxillofacial Surgical Notes in an Indian Public Sector Hospital in Accordance with the Royal College of Surgeons Guidelines: A Completed Audit Loop Study.

    PubMed

    Krishnan, B; Prasad, G Arun; Madhan, B

    2016-09-01

    Proper and adequate documentation in operation notes is a basic tool of clinical practice with medical and legal implications. An audit was done to ascertain if oral and maxillofacial surgery operative notes in an Indian public sector hospital adhered to the guidelines published by the Royal College of Surgeons England. Fifty randomly selected operative notes were evaluated against the guidelines by RCS England with regards to the essential generic components of an operation note. Additional criteria relevant to oral and Maxillofacial Surgery were also evaluated. Changes were introduced in the form of Oral and Maxillofacial Surgery specific consent forms, diagram sheets and a computerized operation note proforma containing all essential and additional criteria along with prefilled template of operative findings. Re-audit of 50 randomly selected operation notes was performed after a 6 month period. In the 1st audit cycle, excellent documentation ranging from 94 to 100 % was seen in 9 essential criteria. Unsatisfactory documentation was observed in criteria like assistant name, date of surgery. Most consent forms contained abbreviations and some did not provide all details. Additional criteria specific to Oral and Maxillofacial Surgery scored poorly. In the 2nd Audit for loop completion, excellent documentation was seen in almost all essential and additional criteria. Mean percentage of data point inclusion improved from 84.6 to 98.4 % (0.001< P value <0.005). The use of abbreviations was seen in only 6 notes. Regular audits are now considered a mandatory quality improvement process that seeks to improve patient care and outcomes. To the best of our knowledge, this is the first completed audit on operation notes documentation in Oral and Maxillofacial Surgery from India. The introduction of a computerized operation note proforma showed excellent improvement in operation note documentation. Surgeons can follow the RCS guidelines to ensure standardization of operation notes.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herberger, Sarah M.; Boring, Ronald L.

    Abstract Objectives: This paper discusses the differences between classical human reliability analysis (HRA) dependence and the full spectrum of probabilistic dependence. Positive influence suggests an error increases the likelihood of subsequent errors or success increases the likelihood of subsequent success. Currently the typical method for dependence in HRA implements the Technique for Human Error Rate Prediction (THERP) positive dependence equations. This assumes that the dependence between two human failure events varies at discrete levels between zero and complete dependence (as defined by THERP). Dependence in THERP does not consistently span dependence values between 0 and 1. In contrast, probabilistic dependencemore » employs Bayes Law, and addresses a continuous range of dependence. Methods: Using the laws of probability, complete dependence and maximum positive dependence do not always agree. Maximum dependence is when two events overlap to their fullest amount. Maximum negative dependence is the smallest amount that two events can overlap. When the minimum probability of two events overlapping is less than independence, negative dependence occurs. For example, negative dependence is when an operator fails to actuate Pump A, thereby increasing his or her chance of actuating Pump B. The initial error actually increases the chance of subsequent success. Results: Comparing THERP and probability theory yields different results in certain scenarios; with the latter addressing negative dependence. Given that most human failure events are rare, the minimum overlap is typically 0. And when the second event is smaller than the first event the max dependence is less than 1, as defined by Bayes Law. As such alternative dependence equations are provided along with a look-up table defining the maximum and maximum negative dependence given the probability of two events. Conclusions: THERP dependence has been used ubiquitously for decades, and has provided approximations of the dependencies between two events. Since its inception, computational abilities have increased exponentially, and alternative approaches that follow the laws of probability dependence need to be implemented. These new approaches need to consider negative dependence and identify when THERP output is not appropriate.« less

  2. Ultrasonographic Evaluation of Cervical Lymph Nodes in Thyroid Cancer.

    PubMed

    Machado, Maria Regina Marrocos; Tavares, Marcos Roberto; Buchpiguel, Carlos Alberto; Chammas, Maria Cristina

    2017-02-01

    Objective To determine what ultrasonographic features can identify metastatic cervical lymph nodes, both preoperatively and in recurrences after complete thyroidectomy. Study Design Prospective. Setting Outpatient clinic, Department of Head and Neck Surgery, School of Medicine, University of São Paulo, Brazil. Subjects and Methods A total of 1976 lymph nodes were evaluated in 118 patients submitted to total thyroidectomy with or without cervical lymph node dissection. All the patients were examined by cervical ultrasonography, preoperatively and/or postoperatively. The following factors were assessed: number, size, shape, margins, presence of fatty hilum, cortex, echotexture, echogenicity, presence of microcalcification, presence of necrosis, and type of vascularity. The specificity, sensitivity, positive predictive value, and negative predictive value of each variable were calculated. Univariate and multivariate logistic regression analyses were conducted. A receiver operator characteristic (ROC) curve was plotted to determine the best cutoff value for the number of variables to discriminate malignant lymph nodes. Results Significant differences were found between metastatic and benign lymph nodes with regard to all of the variables evaluated ( P < .05). Logistic regression analysis revealed that size and echogenicity were the best combination of altered variables (odds ratio, 40.080 and 7.288, respectively) in discriminating malignancy. The ROC curve analysis showed that 4 was the best cutoff value for the number of altered variables to discriminate malignant lymph nodes, with a combined specificity of 85.7%, sensitivity of 96.4%, and efficiency of 91.0%. Conclusion Greater diagnostic accuracy was achieved by associating the ultrasonographic variables assessed rather than by considering them individually.

  3. Individual Traits, Personal Values, and Conflict Resolution in an Isolated, Confined, Extreme Environment.

    PubMed

    Corneliussen, Jesper G; Leon, Gloria R; Kjærgaard, Anders; Fink, Birgit A; Venables, Noah C

    2017-06-01

    The study of personality traits, personal values, and the emergence of conflicts within groups performing in an isolated, confined, and extreme environment (ICE) may provide insights helpful for the composition and support of space crews for long duration missions. Studied pre/post and over the 2-yr period of the investigation were 10 Danish military personnel deployed to stations in Greenland on a 26-mo staggered rotation. Subjects completed the NEO PI-R, Triarchic Psychopathy Measure, and Portrait Values Questionnaire, and participated in structured interviews. During deployment, questionnaires were completed biweekly and a cognitive function test once a month. Personality findings indicated a generally well-adjusted group, above average in positive personality traits [Conscientiousness T-score = 59.4 (11.41); Agreeableness T-score = 54.4 (9.36)] and boldness. Personal values of benevolence and self-direction were highly rated. The decision when to "pick sides" and intervene during disagreements between group members was viewed as an important component of conflict resolution. There were no changes in positive/negative affect or cognitive function over the annual light/dark cycle. The personal values of group members appear highly compatible for living in a small group ICE environment for an extended period. Disagreements between group members impact the functioning of the entire group, particularly in regard to decisions whether to support one of the individuals or let the argument run its course. Extended training in strategies for conflict resolution are needed in planning for future long duration missions to avoid fault lines forming within the group.Corneliussen JG, Leon GR, Kjærgaard A, Fink BA, Venables NC. Individual traits, personal values, and conflict resolution in an isolated, confined, extreme environment. Aerosp Med Hum Perform. 2017; 88(6):535-543.

  4. Transverse occiput position: Using manual Rotation to aid Normal birth and improve delivery OUTcomes (TURN-OUT): A study protocol for a randomised controlled trial.

    PubMed

    de Vries, Bradley; Phipps, Hala; Kuah, Sabrina; Pardey, John; Ludlow, Joanne; Bisits, Andrew; Park, Felicity; Kowalski, David; Hyett, Jon A

    2015-08-18

    Fetal occiput transverse position in the form of deep transverse arrest has long been associated with caesarean section and instrumental vaginal delivery. Occiput transverse position incidentally found in the second stage of labour is also associated with operative delivery in high risk cohorts. There is evidence from cohort studies that prophylactic manual rotation reduces the caesarean section rate. This is a protocol for a double blind, multicentre, randomised, controlled clinical trial to define whether this intervention decreases the operative delivery (caesarean section, forceps or vacuum delivery) rate. Eligible participants will be ≥37 weeks pregnant, with a singleton pregnancy, and a cephalic presentation in the occiput transverse position on transabdominal ultrasound early in the second stage of labour. Based on a background risk of operative delivery of 49%, for a reduction to 35%, an alpha value of 0.05 and a beta value of 0.2, 416 participants will need to be enrolled. Participants will be randomised to either prophylactic manual rotation or a sham procedure. The primary outcome will be operative delivery. Secondary outcomes will be caesarean section, significant maternal mortality and morbidity, and significant perinatal mortality and morbidity. Analysis will be on an intention-to-treat basis. Primary and secondary outcomes will be compared using a chi-squared test. A logistic regression for the primary outcome will be undertaken to account for potential confounders. This study has been approved by the Ethics Review Committee (RPAH Zone) of the Sydney Local Health District, Sydney, Australia, (protocol number: X110410). This trial addresses an important clinical question concerning a commonly used procedure which has the potential to reduce operative delivery and its associated complications. Some issues discussed in the protocol include methods of assessing risk of bias due to inadequate masking of a procedural interventions, variations in intervention efficacy due to operator experience and the recruitment difficulties associated with intrapartum studies. This trial was registered with the Australian New Zealand Clinical Trials Registry (identifier: ACTRN12613000005752 ) on 4 January 2013.

  5. Positive displacement compounding of a heavy duty diesel engine

    NASA Technical Reports Server (NTRS)

    Sekar, R.; Kamo, R.

    1983-01-01

    A helical screw type positive displacement (PD) compressor and expander was considered as an alternative to the turbocharger and the power turbine in the Cummins advanced turbocompound engine. The Institute of Gas Technology (IGT) completed the design, layout, and performance prediction of the PD machines. The results indicate that a screw compressor-expander system is feasible up to at least 750 HP, dry operation of the rotors is feasible, cost and producibility are uncertain, and the system will yield about 4% improvement in brake specific fuel consumption (BSFC) over the advanced turbocompound engine.

  6. The Italian version of the 92-item Prodromal Questionnaire: Concurrent validity with the SIPS and factor analysis in a sample of 258 outpatients aged 11-36years.

    PubMed

    Kotzalidis, Georgios D; Solfanelli, Andrea; Piacentino, Daria; Savoja, Valeria; Fiori Nastro, Paolo; Curto, Martina; Lindau, Juliana Fortes; Masillo, Alice; Brandizzi, Martina; Fagioli, Francesca; Raballo, Andrea; Gebhardt, Eva; Preti, Antonio; D'Alema, Marco; Fucci, Maria Rosa; Miletto, Roberto; Andropoli, Daniela; Leccisi, Donato; Girardi, Paolo; Loewy, Rachel L; Schultze-Lutter, Frauke

    2017-11-01

    Current early screeners for psychosis-risk states have still to prove ability in identifying at-risk individuals. Among screeners, the 92-item Prodromal Questionnaire (PQ-92) is often used. We aimed to assess the validity of its Italian translation in a large Italian adolescent and young adult help-seeking sample. We included all individuals aged 12-36years seeking help at psychiatric mental health services in a large semirural Roman area (534,600 population) who accepted to participate. Participants completed the Italian version of the PQ-92 and were subsequently assessed with the Structured Interview of Prodromal/Psychosis-Risk Syndromes (SIPS). We examined diagnostic accuracy (sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios) and content, concurrent, and convergent validity between PQ-92 and SIPS using Cronbach's alpha, Cohen's kappa, and Spearman's rho, respectively. We tested the validity of adopted cut-offs through Receiver Operating Characteristic (ROC) curves plotted against SIPS diagnoses and the instrument's factor-structure through Principal Component Analysis. PQ-92 showed high internal consistency, acceptable diagnostic accuracy and concurrent validity, and excellent convergent validity. ROC analyses pointed to scores of 18 on the Positive subscale and 36 on the total PQ-92 as best cut-offs. The Scree-test identified a four-factor solution as fitting best. Psychometric properties of Italian PQ-92 were satisfactory. Optimal cut-offs were confirmed at ≥18 on the positive subscale, but at ≥36 on the total scale was able to identify more SIPS-positive cases. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Prediction of Response to Neoadjuvant Chemotherapy and Radiation Therapy with Baseline and Restaging 18F-FDG PET Imaging Biomarkers in Patients with Esophageal Cancer.

    PubMed

    Beukinga, Roelof J; Hulshoff, Jan Binne; Mul, Véronique E M; Noordzij, Walter; Kats-Ugurlu, Gursah; Slart, Riemer H J A; Plukker, John T M

    2018-06-01

    Purpose To assess the value of baseline and restaging fluorine 18 ( 18 F) fluorodeoxyglucose (FDG) positron emission tomography (PET) radiomics in predicting pathologic complete response to neoadjuvant chemotherapy and radiation therapy (NCRT) in patients with locally advanced esophageal cancer. Materials and Methods In this retrospective study, 73 patients with histologic analysis-confirmed T1/N1-3/M0 or T2-4a/N0-3/M0 esophageal cancer were treated with NCRT followed by surgery (Chemoradiotherapy for Esophageal Cancer followed by Surgery Study regimen) between October 2014 and August 2017. Clinical variables and radiomic features from baseline and restaging 18 F-FDG PET were selected by univariable logistic regression and least absolute shrinkage and selection operator. The selected variables were used to fit a multivariable logistic regression model, which was internally validated by using bootstrap resampling with 20 000 replicates. The performance of this model was compared with reference prediction models composed of maximum standardized uptake value metrics, clinical variables, and maximum standardized uptake value at baseline NCRT radiomic features. Outcome was defined as complete versus incomplete pathologic response (tumor regression grade 1 vs 2-5 according to the Mandard classification). Results Pathologic response was complete in 16 patients (21.9%) and incomplete in 57 patients (78.1%). A prediction model combining clinical T-stage and restaging NCRT (post-NCRT) joint maximum (quantifying image orderliness) yielded an optimism-corrected area under the receiver operating characteristics curve of 0.81. Post-NCRT joint maximum was replaceable with five other redundant post-NCRT radiomic features that provided equal model performance. All reference prediction models exhibited substantially lower discriminatory accuracy. Conclusion The combination of clinical T-staging and quantitative assessment of post-NCRT 18 F-FDG PET orderliness (joint maximum) provided high discriminatory accuracy in predicting pathologic complete response in patients with esophageal cancer. © RSNA, 2018 Online supplemental material is available for this article.

  8. LONG-TERM PERFORMANCE OF SOLID OXIDE STACKS WITH ELECTRODE-SUPPORTED CELLS OPERATING IN THE STEAM ELECTROLYSIS MODE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. E. O'Brien; R. C. O'Brien; X. Zhang

    2011-11-01

    Performance characterization and durability testing have been completed on two five-cell high-temperature electrolysis stacks constructed with advanced cell and stack technologies. The solid oxide cells incorporate a negative-electrode-supported multi-layer design with nickel-zirconia cermet negative electrodes, thin-film yttria-stabilized zirconia electrolytes, and multi-layer lanthanum ferrite-based positive electrodes. The per-cell active area is 100 cm2. The stack is internally manifolded with compliant mica-glass seals. Treated metallic interconnects with integral flow channels separate the cells. Stack compression is accomplished by means of a custom spring-loaded test fixture. Initial stack performance characterization was determined through a series of DC potential sweeps in both fuel cellmore » and electrolysis modes of operation. Results of these sweeps indicated very good initial performance, with area-specific resistance values less than 0.5 ?.cm2. Long-term durability testing was performed with A test duration of 1000 hours. Overall performance degradation was less than 10% over the 1000-hour period. Final stack performance characterization was again determined by a series of DC potential sweeps at the same flow conditions as the initial sweeps in both electrolysis and fuel cell modes of operation. A final sweep in the fuel cell mode indicated a power density of 0.356 W/cm2, with average per-cell voltage of 0.71 V at a current of 50 A.« less

  9. Cultural value orientation and authoritarian parenting as parameters of bullying and victimization at school.

    PubMed

    Georgiou, Stelios N; Fousiani, Kyriaki; Michaelides, Michalis; Stavrinides, Panayiotis

    2013-01-01

    The purpose of the present study was to examine the existing association between cultural value orientation, authoritarian parenting, and bullying and victimization at school. The participants (N = 231) were early adolescents, randomly selected from 11 different schools in urban and rural areas of Cyprus. Participants completed self reports measuring cultural value orientation, authoritarian parenting, bullying, and victimization. These instruments were the following: the cultural value scale (CVS), the parental authority questionnaire (PAQ), and the revised bullying and victimization questionnaire (BVQ-R). Structural equation modeling (SEM) was used to examine mediation effects. It was found that vertical individualism acted as a mediator between authoritarian parenting and bullying. Statistically significant positive correlations were found between authoritarian parenting and the vertical dimensions of both cultural value orientations (individualism and collectivism), but not with the horizontal dimensions of either cultural orientation. Further, authoritarian parenting was also positively associated with bullying and victimization at school. The main contribution of the present study is the finding that vertical individualism significantly mediates the relationship between authoritarian parental style and bullying propensity.

  10. Cesium and Rubidium Frequency Standards Status and Performance on the GPS Program

    NASA Technical Reports Server (NTRS)

    VanMelle, M. J.

    1996-01-01

    This paper is an update of the on-orbit operational performance of the frequency standards on the last Block 1 Navstar satellite (GPS-10), the complete Block 2 Navstar satellites (GPS-13 to 21) and the Block 2A Navstar (GPS-22 to 40) satellites. Since the status of the GPS constellation is now at full operational capability (FOC), a minimum of twenty-four satellites are in position with all the necessary tests successfully completed. The evolution of frequency standards on board the GPS vehicles will be presented with corresponding results. Various methods and techniques will be presented to show on-orbit life time, down time, state of health telemetry, on-orbit trending and characterization of all the frequency standards. Other topics such as reliability, stability, clock quirks and idiosyncrasies of each vehicle will be covered.

  11. Normal form decomposition for Gaussian-to-Gaussian superoperators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Palma, Giacomo; INFN, Pisa; Mari, Andrea

    2015-05-15

    In this paper, we explore the set of linear maps sending the set of quantum Gaussian states into itself. These maps are in general not positive, a feature which can be exploited as a test to check whether a given quantum state belongs to the convex hull of Gaussian states (if one of the considered maps sends it into a non-positive operator, the above state is certified not to belong to the set). Generalizing a result known to be valid under the assumption of complete positivity, we provide a characterization of these Gaussian-to-Gaussian (not necessarily positive) superoperators in terms ofmore » their action on the characteristic function of the inputs. For the special case of one-mode mappings, we also show that any Gaussian-to-Gaussian superoperator can be expressed as a concatenation of a phase-space dilatation, followed by the action of a completely positive Gaussian channel, possibly composed with a transposition. While a similar decomposition is shown to fail in the multi-mode scenario, we prove that it still holds at least under the further hypothesis of homogeneous action on the covariance matrix.« less

  12. Academic stress and positive affect: Asian value and self-worth contingency as moderators among Chinese international students.

    PubMed

    Liao, Kelly Yu-Hsin; Wei, Meifen

    2014-01-01

    The theoretical model proposed by Berry and colleagues (Berry, 1997; Berry, Kim, Minde, & Mok, 1987) highlights the importance of identifying moderators in the acculturation process. Accordingly, the current study examined the Asian cultural value of family recognition through achievement (FRTA) and contingency of self-worth on academic competence (CSW-AC) as moderators in the association between academic stress and positive affect among Chinese international students. A total of 370 Chinese international students completed online surveys. Results from a hierarchical regression indicated that while academic stress was negatively associated with positive affect, FRTA was positively associated with positive affect. In other words, those with high academic stress reported a lower level of positive affect. However, individuals who endorsed high levels of FRTA reported a higher level of positive affect. In addition, results also revealed a significant interaction between academic stress and CSW-AC on positive affect. Thus, the study's finding supported the moderator role of CSW-AC. Simple effect analyses were conducted to examine the significant interaction. The results showed that higher levels of CSW-AC strengthened the negative association between academic stress and positive affect but lower levels of CSW-AC did not. Future research directions and implications are discussed.

  13. Creating an environment for patient safety and teamwork training in the operating theatre: A quasi-experimental study.

    PubMed

    Wallin, Carl-Johan; Kalman, Sigridur; Sandelin, Annika; Färnert, May-Lena; Dahlstrand, Ursula; Jylli, Leena

    2015-03-01

    Positive safety and a teamwork climate in the training environment may be a precursor for successful teamwork training. This pilot project aimed to implement and test whether a new interdisciplinary and team-based approach would result in a positive training climate in the operating theatre. A 3-day educational module for training the complete surgical team of specialist nursing students and residents in safe teamwork skills in an authentic operative theatre, named Co-Op, was implemented in a university hospital. Participants' (n=22) perceptions of the 'safety climate' and the 'teamwork climate', together with their 'readiness for inter-professional learning', were measured to examine if the Co-Op module produced a positive training environment compared with the perceptions of a control group (n=11) attending the conventional curriculum. The participants' perceptions of 'safety climate' and 'teamwork climate' and their 'readiness for inter-professional learning' scores were significantly higher following the Co-Op module compared with their perceptions following the conventional curriculum, and compared with the control group's perceptions following the conventional curriculum. The Co-Op module improved 'safety climate' and 'teamwork climate' in the operating theatre, which suggests that a deliberate and designed educational intervention can shape a learning environment as a model for the establishment of a safety culture.

  14. Stability effects of singularities in force-controlled robotic assist devices

    NASA Astrophysics Data System (ADS)

    Luecke, Greg R.

    2002-02-01

    Force feedback is being used as an interface between humans and material handling equipment to provide an intuitive method to control large and bulky payloads. Powered actuation in the lift assist device compensates for the inertial characteristics of the manipulator and the payload to provide effortless control and handling of manufacturing parts, components, and assemblies. The use of these Intelligent Assist Devices (IAD) is being explored to prevent worker injury, enhance material handling performance, and increase productivity in the workplace. The IAD also provides the capability to shape and control motion in the workspace during routine operations. Virtual barriers can be developed to protect fixed objects in the workspace, and regions can be programmed that attract the work piece to a certain position and orientation. However, the robot is still under complete control of the human operator, with the trajectory being determined and commanded using the judgment of the operator to complete a given task. In many cases, the IAD is built in a configuration that may have singular points inside the workspace. These singularities can cause problems when the unstructured trajectory commands from the human cause interaction between the IAD and the virtual walls and fixtures at positions close to these singularities. The research presented here explores the stability effects of the interactions between the powered manipulator and the virtual surfaces when controlled by the operator. Because of the flexible nature of the human decisions determining the real time work piece paths, manipulator singularities that occur in conjunction with the virtual surfaces raise stability issues in the performance around these singularities. We examine these stability issues in the context of a particular IAD configuration, and present analytic results for the performance and stability of these systems in response to the real-time trajectory modification of the human operator.

  15. Predictive value and construct validity of the work functioning screener-healthcare (WFS-H).

    PubMed

    Boezeman, Edwin J; Nieuwenhuijsen, Karen; Sluiter, Judith K

    2016-05-25

    To test the predictive value and convergent construct validity of a 6-item work functioning screener (WFS-H). Healthcare workers (249 nurses) completed a questionnaire containing the work functioning screener (WFS-H) and a work functioning instrument (NWFQ) measuring the following: cognitive aspects of task execution and general incidents, avoidance behavior, conflicts and irritation with colleagues, impaired contact with patients and their family, and level of energy and motivation. Productivity and mental health were also measured. Negative and positive predictive values, AUC values, and sensitivity and specificity were calculated to examine the predictive value of the screener. Correlation analysis was used to examine the construct validity. The screener had good predictive value, since the results showed that a negative screener score is a strong indicator of work functioning not hindered by mental health problems (negative predictive values: 94%-98%; positive predictive values: 21%-36%; AUC:.64-.82; sensitivity: 42%-76%; and specificity 85%-87%). The screener has good construct validity due to moderate, but significant (p<.001), associations with productivity (r=.51), mental health (r=.48), and distress (r=.47). The screener (WFS-H) had good predictive value and good construct validity. Its score offers occupational health professionals a helpful preliminary insight into the work functioning of healthcare workers.

  16. Interrelation and independence of positive and negative psychological constructs in predicting general treatment adherence in coronary artery patients - Results from the THORESCI study.

    PubMed

    van Montfort, Eveline; Denollet, Johan; Widdershoven, Jos; Kupper, Nina

    2016-09-01

    In cardiac patients, positive psychological factors have been associated with improved medical and psychological outcomes. The current study examined the interrelation between and independence of multiple positive and negative psychological constructs. Furthermore, the potential added predictive value of positive psychological functioning regarding the prediction of patients' treatment adherence and participation in cardiac rehabilitation (CR) was investigated. 409 percutaneous coronary intervention (PCI) patients were included (mean age = 65.6 ± 9.5; 78% male). Self-report questionnaires were administered one month post-PCI. Positive psychological constructs included positive affect (GMS) and optimism (LOT-R); negative constructs were depression (PHQ-9, BDI), anxiety (GAD-7) and negative affect (GMS). Six months post-PCI self-reported general adherence (MOS) and CR participation were determined. Factor Analysis (Oblimin rotation) revealed two components (r = − 0.56), reflecting positive and negative psychological constructs. Linear regression analyses showed that in unadjusted analyses both optimism and positive affect were associated with better general treatment adherence at six months (p < 0.05). In adjusted analyses, optimism's predictive values remained, independent of sex, age, PCI indication, depression and anxiety. Univariate logistic regression analysis showed that in patients with a cardiac history, positive affect was significantly associated with CR participation. After controlling for multiple covariates, this relation was no longer significant. Positive and negative constructs should be considered as two distinct dimensions. Positive psychological constructs (i.e. optimism) may be of incremental value to negative psychological constructs in predicting patients' treatment adherence. A more complete view of a patients' psychological functioning will open new avenues for treatment. Additional research is needed to investigate the relationship between positive psychological factors and other cardiac outcomes, such as cardiac events and mortality.

  17. Otto Skorzeny and the Real Conduct of Unternehmen Eiche and Unternehmen Panzerfaust

    DTIC Science & Technology

    2017-12-01

    for Skorzeny and his men. These psychological operations had positive effects; American troops who protected General Eisenhower became increasingly on...edge, and American troops as a whole became agitated when numerous American Prisoners of War were claimed to be Germans or German agents.168...Skorzeny as “the most dangerous man in Europe.”1 The Austrian SS-Obersturmbannführer successfully led several high -value-target special operations for

  18. Single Crystal Diamond Beam Position Monitors with Radiofrequency Electronic Readout

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solar, B.; Graafsma, H.; Potdevin, G.

    2010-06-23

    Over the energy range 5{approx}30 keV a suitably contacted, thin ({approx}100 {mu}m) diamond plate can be operated in situ as a continuous monitor of X-ray beam intensity and position as the diamond absorbs only a small percentage of the incident beam. Single crystal diamond is a completely homogeneous material showing fast (ns), spatially uniform signal response and negligible (

  19. A multicenter, prospective, randomized comparison of a novel signal transmission capsule endoscope to an existing capsule endoscope.

    PubMed

    Choi, Eric H; Mergener, Klaus; Semrad, Carol; Fisher, Laurel; Cave, David R; Dodig, Milan; Burke, Carol; Leighton, Jonathan A; Kastenberg, David; Simpson, Peter; Sul, James; Bhattacharya, Kanishka; Charles, Roger; Gerson, Lauren; Weber, Luke; Eisen, Glenn; Reidel, Warren; Vargo, John J; Wakim-Fleming, Jamile; Lo, Simon K

    2013-08-01

    MiroCam, a capsule endoscope, uses a novel transmission technology, electric-field propagation, which uses the human body as a conduction medium for data transmission. To compare the ability of the MiroCam (MC) and PillCam (PC) to identify sources of obscure GI bleeding (OGIB). Prospective, multicenter, comparative study. Six academic hospitals. A total of 105 patients with OGIB. Patients ingested both the MC and PC capsules sequentially in a randomized fashion. Concordance of rates in identifying a source of OGIB, operational times, and rates of complete small-bowel examination. Data analysis resulted in 43 (48%) "abnormal" cases identifying a source of OGIB by either capsule. Twenty-four cases (55.8%) were positive by both capsules. There was negative agreement in 46 of 58 cases (79.3%). The κ index was 0.547 (χ(2) = 1.32; P = .36). In 12 cases, MC positively identified a source that was not seen on PC, whereas in 7 cases, PC positively identified a source that was not seen on MC. MC had a 5.6% higher rate of detecting small-bowel lesions (P = .54). MC captured images at 3 frames per second for 11.1 hours, and PC captured images at 2 frames per second for 7.8 hours (P < .0001). Complete small-bowel examination was achieved in 93.3% for MC and 84.3% for PC (P = .10). Readers were not blinded to the particular capsule they were reading. A positive diagnostic finding for OGIB was identified by either capsule in 48% of cases. The concordance rate between the 2 capsules was comparable to that of prior studies in identifying sources of small-bowel bleeding. The longer operational time of the MC may result in higher rates of complete small-bowel examination, which may, in turn, translate into a higher rate of detecting small-bowel lesions. ( NCT00878982.). Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  20. Examining the Perceptions of Parental Involvement in Schools: Implications for Changing Roles for School Leaders from the Voices of the Community

    ERIC Educational Resources Information Center

    Jojola, Tracia Keri

    2011-01-01

    Research studies have demonstrated that effective parental involvement correlates with positive academic success. This study sought to gain more insight into the perceptions of parents and caregivers of Navajo children enrolled in a K-12 tribally controlled, public, charter, or Bureau of Indian Education (BIE) operated schools. By completing a…

  1. Update Study of the Financial Condition of Independent Higher Education in the Commonwealth of Pennsylvania.

    ERIC Educational Resources Information Center

    Commission for Independent Colleges and Universities, Harrisburg, PA.

    A study completed in Winter 1971 report on the financial condition of institutions affiliated with the Commission for Independent Colleges and Universities (CICU). Its analysis showed a steady deterioration of financial operating results from a positive $10 million to a negative $1 million. The purpose of the present study was to: (1) measure the…

  2. Field trial of applicability of lot quality assurance sampling survey method for rapid assessment of prevalence of active trachoma.

    PubMed Central

    Myatt, Mark; Limburg, Hans; Minassian, Darwin; Katyola, Damson

    2003-01-01

    OBJECTIVE: To test the applicability of lot quality assurance sampling (LQAS) for the rapid assessment of the prevalence of active trachoma. METHODS: Prevalence of active trachoma in six communities was found by examining all children aged 2-5 years. Trial surveys were conducted in these communities. A sampling plan appropriate for classifying communities with prevalences < or =20% and > or =40% was applied to the survey data. Operating characteristic and average sample number curves were plotted, and screening test indices were calculated. The ability of LQAS to provide a three-class classification system was investigated. FINDINGS: Ninety-six trial surveys were conducted. All communities with prevalences < or =20% and > or =40% were identified correctly. The method discriminated between communities with prevalences < or =30% and >30%, with sensitivity of 98% (95% confidence interval (CI)=88.2-99.9%), specificity of 84.4% (CI=69.9-93.0%), positive predictive value of 87.7% (CI=75.7-94.5%), negative predictive value of 97.4% (CI=84.9-99.9%), and accuracy of 91.7% (CI=83.8-96.1%). Agreement between the three prevalence classes and survey classifications was 84.4% (CI=75.2-90.7%). The time needed to complete the surveys was consistent with the need to complete a survey in one day. CONCLUSION: Lot quality assurance sampling provides a method of classifying communities according to the prevalence of active trachoma. It merits serious consideration as a replacement for the assessment of the prevalence of active trachoma with the currently used trachoma rapid assessment method. It may be extended to provide a multi-class classification method. PMID:14997240

  3. Vanguard/PLACE experiment system design and test plan

    NASA Technical Reports Server (NTRS)

    Taylor, R. E.

    1973-01-01

    A system design and test plan are described for operational evaluation of the NASA-Goddard position location and aircraft communications equipment (PLACE), at C band (4/6GHz), using NASA's ship, the USNS Vanguard, and the ATS 3 and ATS 5 synchronous satellites. The Sea Test phase, extending from March 29, 1973 to April 15, 1973 was successfully completed; the principal objectives of the experiment were achieved. Typical PLACE-computed, position-location data is shown for the Vanguard. Position location and voice-quality measurements were excellent; ship position was determined within 2 nmi; high-quality, 2-way voice transmissions resulted as determined from audience participation, intelligibility and articulation-index analysis. A C band/L band satellite trilateration experiment is discussed.

  4. A Survey on Evaluation Practices in Teaching and Learning Centres

    ERIC Educational Resources Information Center

    Kolomitro, Klodiana; Anstey, Lauren M.

    2017-01-01

    There is general consensus that teaching and learning centres have a positive impact on promoting and supporting a culture that values teaching and learning, yet there is limited evidence on how centres evaluate their work. For this purpose, a survey was developed and administered to the directors of 88 Canadian centres; 46 of which completed the…

  5. Textural features of 18F-FDG PET after two cycles of neoadjuvant chemotherapy can predict pCR in patients with locally advanced breast cancer.

    PubMed

    Cheng, Lin; Zhang, Jianping; Wang, Yujie; Xu, Xiaoli; Zhang, Yongping; Zhang, Yingjian; Liu, Guangyu; Cheng, Jingyi

    2017-08-01

    This study was designed to evaluate the utility of textural features for predicting pathological complete response (pCR) to neoadjuvant chemotherapy (NAC). Sixty-one consecutive patients with locally advanced breast cancer underwent 18 F-FDG PET/CT scanning at baseline and after the second course of NAC. Changes to imaging parameters [maximum standardized uptake value (SUV max ), metabolic tumor volume (MTV), total lesion glycolysis (TLG)] and textural features (entropy, coarseness, skewness) between the 2 scans were measured by two independent radiologists. Pathological responses were reviewed by one pathologist, and the significance of the predictive value of each parameter was analyzed using a Chi-squared test. Receiver operating characteristic curve analysis was used to compare the area under the curve (AUC) for each parameter. pCR was observed more often in patients with HER2-positive tumors (22 patients) than in patients with HER2-negative tumors (5 patients) (71.0 vs. 16.7%, p < 0.001). ∆ %SUV max , ∆ %entropy and ∆ %coarseness were significantly useful for differentiating pCR from non-pCR in the HER2-negative group, and the AUCs for these parameters were 0.928, 0.808 and 0.800, respectively (p = 0.003, 0.032 and 0.037). In the HER2-positive group, ∆ %SUV max and ∆ %skewness were moderately useful for predicting pCR, and the respective AUCs were 0.747 and 0.758 (p = 0.033 and 0.026). Although there was no significant difference in the AUCs between groups for these parameters, an additional 3/22 patients in the HER2-positive group with pCR were identified when ∆ %skewness and ∆ %SUV max were considered together (p = 0.031). The absolute values for each parameter before NAC and after 2 cycles cannot predict pCR in our patients. Neither ∆ %MTV nor ∆ %TLG was efficiently predictive of pCR in any group. The early changes in the textural features of 18 F-FDG PET images after two cycles of NAC are predictive of pCR in both HER2-negative and HER2-positive patients; this evidence warrants confirmation by further research.

  6. Educational Gaming for Pharmacy Students - Design and Evaluation of a Diabetes-themed Escape Room.

    PubMed

    Eukel, Heidi N; Frenzel, Jeanne E; Cernusca, Dan

    2017-09-01

    Objective. To design an educational game that will increase third-year professional pharmacy students' knowledge of diabetes mellitus disease management and to evaluate their perceived value of the game. Methods. Faculty members created an innovative educational game, the diabetes escape room. An authentic escape room gaming environment was established through the use of a locked room, an escape time limit, and game rules within which student teams completed complex puzzles focused on diabetes disease management. To evaluate the impact, students completed a pre-test and post-test to measure the knowledge they've gained and a perception survey to identify moderating factors that could help instructors improve the game's effectiveness and utility. Results. Students showed statistically significant increases in knowledge after completion of the game. A one-sample t -test indicated that students' mean perception was statistically significantly higher than the mean value of the evaluation scale. This statically significant result proved that this gaming act offers a potential instructional benefit beyond its novelty. Conclusion. The diabetes escape room proved to be a valuable educational game that increased students' knowledge of diabetes mellitus disease management and showed a positive perceived overall value by student participants.

  7. The 6-item Kessler psychological distress scale to survey serious mental illness among Chinese undergraduates: Psychometric properties and prevalence estimate.

    PubMed

    Kang, Yu-kun; Guo, Wan-jun; Xu, Hao; Chen, Yue-hui; Li, Xiao-jing; Tan, Zheng-ping; Li, Na; Gesang, Ze-Ren; Wang, Ying-mei; Liu, Chang-bo; Luo, Ying; Feng, Jia; Xu, Qiu-jie; Lee, Sing; Li, Tao

    2015-11-01

    To evaluate the psychometric properties of the 6-item Kessler psychological distress scale (K6) in screening for serious mental illness (SMI) among undergraduates in a major comprehensive university in China. The K6 was self-completed by 8289 randomly sampled participants. A group of them (n=222) were re-assessed using K6 and interviewed using the Chinese version of Composite International Diagnostic Interview 3.1 (CIDI-3.1). The test-retest reliability of the K6 scale was 0.79, the Cronbach's alpha was 0.84, and its area under the receiver operating curve (AUC) for diagnosing CIDI-3.1 SMI was 0.85 (95% CI=0.80-0.90). For the optimal cut-off of K6 (12/13), the sensitivity (SEN), specificity (SPE), positive predictive value (PPV), negative predictive value (NPV), and classification accuracy (AC) were 0.83, 0.79, 0.60, 0.93, and 0.80, respectively. The 12-month prevalence of SMI was estimated as 3.97% using this optimal cut-off. Binary logistic regression analysis (including gender, ethnicity, grade, number of siblings and family residency location) showed that only family residency location in rural areas compared to urban areas was significantly associated with more SMI. This study documented the value of using the K6 for detecting SMI in Chinese undergraduate populations and supported its cross-cultural reliability and validity. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Simulation and Analysis of Electric Field for the Disconnector Switch Incomplete Opening Position Based on 220kV GIS

    NASA Astrophysics Data System (ADS)

    Wang, Feifeng; Huang, Huimin; Su, Yi; Yan, Dandan; Lu, Yufeng; Xia, Xiaofei; Yang, Jian

    2018-05-01

    It has accounted for a large proportion of GIS equipment defects, which cause the disconnector switches to incomplete open-close position. Once opening operation is not in place, it will arouse continuous arcing between contacts to reduce insulation strength. Otherwise, the intense heat give rise to burn the contact, which has a severe effect on the safe operation of power grid. This paper analyzes some typical defection cases about the opening operation incomplete for disconnector switches of GIS. The COMSOL Multiphysics is applied to verify the influence on electric field distribution. The results show that moving contact out shield is 20 mm, the electric field distribution of the moving contact surface is uneven, and the maximum electric field value can reach 9.74 kV/mm.

  9. Methods to Improve Sustainability of a Large Academic Biorepository

    PubMed Central

    Wiehagen, Luke T.; Schumacher, Philip E.; Dhir, Rajiv

    2017-01-01

    This article discusses the evolution of the University of Pittsburgh (UPitt) Health Sciences Tissue Bank (HSTB) operation and how it has successfully positioned itself, manages to sustain its value, and remains viable in today's research landscape. We describe the various components of our biobanking operation, which are valued by our researchers, thus leading to sustainability for our biorepository. Operating within the infrastructure of a large academic university, we have access to the most cutting-edge database resources for collecting, tracking, and annotating thousands of specimens. We are constantly improving upon our ability to provide real-time longitudinal follow-up data for our collections, thus providing researchers with valuable, highly annotated research specimens. We believe the combination of all that is described within this article helps to create a biobank that will remain sustainable well into the future. PMID:27860489

  10. Considerations for NSLS-II Synchrotron Radiation Protection When Operating Damping Wigglers at Low Machine Energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seletskiy, S.; Podobedov, B.

    2015-12-30

    The NSLS-II storage ring vacuum chamber, including frontends (FE) and beamlines (BL), is protected from possible damage from synchrotron radiation (SR) emitted from insertion devices (IDs) by a dedicated active interlock system (AIS). The system monitors electron beam position and angle and triggers a beam dump if the beam orbit is outside of the active interlock envelope (AIE). The AIE was calculated under the assumptions of 3 GeV beam energy and ID gaps set to their minimum operating values (i.e. “fully closed”). Recently it was proposed to perform machine studies that would ramp the stored beam energy significantly below themore » nominal operational value of 3 GeV. These studies may potentially include the use of NSLS-II damping wigglers (DWs) for electron beam emittance reduction and control.« less

  11. Wire Rope Failure on the Guppy Winch

    NASA Technical Reports Server (NTRS)

    Figert, John

    2016-01-01

    On January 6, 2016 at El Paso, the Guppy winch motor was changed. After completion of the operational checks, the load bar was being reinstalled on the cargo pallet when the motor control FORWARD relay failed in the energized position. The pallet was pinned at all locations (each pin has a load capacity of 16,000 lbs.) while the winch was running. The wire rope snapped before aircraft power could be removed. After disassembly, the fractured wire rope was shipped to ES4 lab for further characterization of the wire rope portion of the failure. The system was being operated without a clear understanding of the system capability and function. The proximate cause was the failure of the K48 -Forward Winch Control Relay in the energized position, which allowed the motor to continuously run without command from the hand controller, and operation of the winch system with both controllers connected to the system. This prevented the emergency stop feature on the hand controller from functioning as designed. An electrical checkout engineering work instruction was completed and identified the failed relay and confirmed the emergency stop only paused the system when the STOP button on both connected hand controllers were depressed simultaneously. The winch system incorporates a torque limiting clutch. It is suspected that the clutch did not slip and the motor did not stall or overload the current limiter. Aircraft Engineering is looking at how to change the procedures to provide a checkout of the clutch and set to a slip torque limit appropriate to support operations.

  12. Point-of-care ultrasound versus auscultation in determining the position of double-lumen tube

    PubMed Central

    Hu, Wei-Cai; Xu, Lei; Zhang, Quan; Wei, Li; Zhang, Wei

    2018-01-01

    Abstract This study was designed to assess the accuracy of point-of-care ultrasound in determining the position of double-lumen tubes (DLTs). A total of 103 patients who required DLT intubation were enrolled into the study. After DLTs were tracheal intubated in the supine position, an auscultation researcher and ultrasound researcher were sequentially invited in the operating room to conduct their evaluation of the DLT. After the end of their evaluation, fiberscope researchers (FRs) were invited in the operating room to evaluate the position of DLT using a fiberscope. After the patients were changed to the lateral position, the same evaluation process was repeated. These 3 researchers were blind to each other when they made their conclusions. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were obtained by statistical analysis. When left DLTs (LDLTs) were used, the accuracy of ultrasound (84.2% [72.1%, 92.5%]) was higher than the accuracy of auscultation (59.7% [45.8%, 72.4%]) (P < .01). When right DLTs (RDLTs) were used, the accuracy of ultrasound (89.1% [76.4%, 96.4%]) was higher than the accuracy of auscultation (67.4% [52.0%, 80.5%]) (P < .01). When LDLTs were used in the lateral position, the accuracy of ultrasound (75.4% [62.2%, 85.9%]) was higher than the accuracy of auscultation (54.4% [40.7%, 67.6%]) (P < .05). When RDLT were used, the accuracy of ultrasound (73.9% [58.9%, 85.7%]) was higher than the accuracy of auscultation (47.8% [32.9%, 63.1%]) (P < .05). Assessment via point-of-care ultrasound is superior to auscultation in determining the position of DLTs. PMID:29595696

  13. Point-of-care ultrasound versus auscultation in determining the position of double-lumen tube.

    PubMed

    Hu, Wei-Cai; Xu, Lei; Zhang, Quan; Wei, Li; Zhang, Wei

    2018-03-01

    This study was designed to assess the accuracy of point-of-care ultrasound in determining the position of double-lumen tubes (DLTs).A total of 103 patients who required DLT intubation were enrolled into the study. After DLTs were tracheal intubated in the supine position, an auscultation researcher and ultrasound researcher were sequentially invited in the operating room to conduct their evaluation of the DLT. After the end of their evaluation, fiberscope researchers (FRs) were invited in the operating room to evaluate the position of DLT using a fiberscope. After the patients were changed to the lateral position, the same evaluation process was repeated. These 3 researchers were blind to each other when they made their conclusions. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were obtained by statistical analysis.When left DLTs (LDLTs) were used, the accuracy of ultrasound (84.2% [72.1%, 92.5%]) was higher than the accuracy of auscultation (59.7% [45.8%, 72.4%]) (P < .01). When right DLTs (RDLTs) were used, the accuracy of ultrasound (89.1% [76.4%, 96.4%]) was higher than the accuracy of auscultation (67.4% [52.0%, 80.5%]) (P < .01). When LDLTs were used in the lateral position, the accuracy of ultrasound (75.4% [62.2%, 85.9%]) was higher than the accuracy of auscultation (54.4% [40.7%, 67.6%]) (P < .05). When RDLT were used, the accuracy of ultrasound (73.9% [58.9%, 85.7%]) was higher than the accuracy of auscultation (47.8% [32.9%, 63.1%]) (P < .05).Assessment via point-of-care ultrasound is superior to auscultation in determining the position of DLTs.

  14. Robot Position Sensor Fault Tolerance

    NASA Technical Reports Server (NTRS)

    Aldridge, Hal A.

    1997-01-01

    Robot systems in critical applications, such as those in space and nuclear environments, must be able to operate during component failure to complete important tasks. One failure mode that has received little attention is the failure of joint position sensors. Current fault tolerant designs require the addition of directly redundant position sensors which can affect joint design. A new method is proposed that utilizes analytical redundancy to allow for continued operation during joint position sensor failure. Joint torque sensors are used with a virtual passive torque controller to make the robot joint stable without position feedback and improve position tracking performance in the presence of unknown link dynamics and end-effector loading. Two Cartesian accelerometer based methods are proposed to determine the position of the joint. The joint specific position determination method utilizes two triaxial accelerometers attached to the link driven by the joint with the failed position sensor. The joint specific method is not computationally complex and the position error is bounded. The system wide position determination method utilizes accelerometers distributed on different robot links and the end-effector to determine the position of sets of multiple joints. The system wide method requires fewer accelerometers than the joint specific method to make all joint position sensors fault tolerant but is more computationally complex and has lower convergence properties. Experiments were conducted on a laboratory manipulator. Both position determination methods were shown to track the actual position satisfactorily. A controller using the position determination methods and the virtual passive torque controller was able to servo the joints to a desired position during position sensor failure.

  15. Experts opinion on the use of normative data for functional capacity evaluation in occupational and rehabilitation medicine and disability claims.

    PubMed

    Soer, Remko; Reneman, Michiel F; Frings-Dresen, Monique H W; Kuijer, P Paul; Kuijer, P Paul F M

    2014-12-01

    Application of normative values for functional capacity evaluation (FCE) is controversial for the assessment of clients for work ability. The objective of this study was to study when clinicians and researchers consider normative values of FCE useful or of no use for their purposes. A focus group meeting was organized among 43 FCE experts working in insurance, occupational and/or rehabilitation medicine from eight countries during the first international FCE research meeting on October 25th, 2012 in the Netherlands. Participants were asked to rate to which degree they agree or disagree with a statement concerning their position toward normative values for FCE on a 10 cm VAS ranging from 0 (completely disagree) to 100 (completely agree) at T0 and T1. Arguments for aspects that are useful and of no use for normative values were systematically collected during the meeting and afterwards independently clustered by two researchers in higher order topics. Baseline opinion of participants on their position toward normative values was 49 ± 29 points. After the meeting, mean VAS was 55 ± 23 (p = 0.07), indicating that participants did not significantly change their opinion toward normative values. Based on arguments provided by the experts, seven higher order topics were constructed namely 'Comparison with job demands or treatment goals'; 'Comparison with co-workers physical ability'; 'Sincerity of effort'; 'Validity for work ability and return to work'; 'Experience of referrer with assessment method'; 'Clinimetrics compared to alternative assessment methods or reference values'; and 'Ease of use for clinician and stakeholders'. Although experts state useful aspects for the use of normative values of FCE for these assessments, it may also lead to over-interpretation of results, leading to dualistic statements concerning work ability, with potential harmful consequences for work ability of patients.

  16. Completion of the Design of the Top End Optical Assembly for ATST

    NASA Astrophysics Data System (ADS)

    Canzian, Blaise; Barentine, J.

    2013-01-01

    L-3 Integrated Optical Systems (IOS) Division has been selected by the National Solar Observatory (NSO) to make the Top End Optical Assembly (TEOA) for the 4-meter Advanced Technology Solar Telescope (ATST) to operate at Haleakala, Maui. ATST will perform to a very high optical performance level in a difficult operational environment. The TEOA (including a 0.65-meter silicon carbide secondary mirror and support, mirror thermal management system, mirror positioning and fast tip-tilt system, field stop with thermally managed heat dump, Lyot stop, safety interlock and control system, and support frame) operates in the “hot spot” at the prime focus of the ATST, presenting unusual challenges. L-3 IOS has passed Critical Design Review of the TEOA. In this paper, we describe L-3 IOS success meeting technical challenges, including our solutions for optic fabrication, opto-mechanical positioning, rejected and stray light control, wavefront tip-tilt compensation, and thermal management and control.

  17. Interview with Janet Woodcock: progress on the FDA's critical path initiative.

    PubMed

    Woodcock, Janet

    2009-12-01

    Janet Woodcock is the Director of the US FDA's Center for Drug Evaluation and Research. Dr Woodcock has held various positions within the FDA's Office of the Commissioner from October 2003 until 1 April, 2008, as Deputy Commissioner and Chief Medical Officer, Deputy Commissioner for Operations and Chief Operating Officer and Director of the Critical Path Programs. She oversaw scientific and medical regulatory operations for the FDA. Dr Woodcock served as Director of the Center for Drug Evaluation and Research at the FDA from 1994 to 2005. She previously served in other positions at the FDA including Director of the Office of Therapeutics Research and Review and Acting Deputy Director of the Center for Biologics Evaluation and Research. Dr Woodcock received her MD from Northwestern Medical School (IL, USA), and completed further training and held teaching appointments at the Pennsylvania State University (PA, USA)and the University of California in San Francisco (CA, USA). She joined the FDA in 1986.

  18. Automated classification of seismic sources in a large database: a comparison of Random Forests and Deep Neural Networks.

    NASA Astrophysics Data System (ADS)

    Hibert, Clement; Stumpf, André; Provost, Floriane; Malet, Jean-Philippe

    2017-04-01

    In the past decades, the increasing quality of seismic sensors and capability to transfer remotely large quantity of data led to a fast densification of local, regional and global seismic networks for near real-time monitoring of crustal and surface processes. This technological advance permits the use of seismology to document geological and natural/anthropogenic processes (volcanoes, ice-calving, landslides, snow and rock avalanches, geothermal fields), but also led to an ever-growing quantity of seismic data. This wealth of seismic data makes the construction of complete seismicity catalogs, which include earthquakes but also other sources of seismic waves, more challenging and very time-consuming as this critical pre-processing stage is classically done by human operators and because hundreds of thousands of seismic signals have to be processed. To overcome this issue, the development of automatic methods for the processing of continuous seismic data appears to be a necessity. The classification algorithm should satisfy the need of a method that is robust, precise and versatile enough to be deployed to monitor the seismicity in very different contexts. In this study, we evaluate the ability of machine learning algorithms for the analysis of seismic sources at the Piton de la Fournaise volcano being Random Forest and Deep Neural Network classifiers. We gather a catalog of more than 20,000 events, belonging to 8 classes of seismic sources. We define 60 attributes, based on the waveform, the frequency content and the polarization of the seismic waves, to parameterize the seismic signals recorded. We show that both algorithms provide similar positive classification rates, with values exceeding 90% of the events. When trained with a sufficient number of events, the rate of positive identification can reach 99%. These very high rates of positive identification open the perspective of an operational implementation of these algorithms for near-real time monitoring of mass movements and other environmental sources at the local, regional and even global scale.

  19. Kraus Operators for a Pair of Interacting Qubits: a Case Study

    NASA Astrophysics Data System (ADS)

    Arsenijević, M.; Jeknić-Dugić, J.; Dugić, M.

    2018-04-01

    The Kraus form of the completely positive dynamical maps is appealing from the mathematical and the point of the diverse applications of the open quantum systems theory. Unfortunately, the Kraus operators are poorly known for the two-qubit processes. In this paper, we derive the Kraus operators for a pair of interacting qubits, while the strength of the interaction is arbitrary. One of the qubits is subjected to the x-projection spin measurement. The obtained results are applied to calculate the dynamics of the entanglement in the qubits system. We obtain the loss of the correlations in the finite time interval; the stronger the inter-qubit interaction, the longer lasting entanglement in the system.

  20. Kraus Operators for a Pair of Interacting Qubits: a Case Study

    NASA Astrophysics Data System (ADS)

    Arsenijević, M.; Jeknić-Dugić, J.; Dugić, M.

    2018-06-01

    The Kraus form of the completely positive dynamical maps is appealing from the mathematical and the point of the diverse applications of the open quantum systems theory. Unfortunately, the Kraus operators are poorly known for the two-qubit processes. In this paper, we derive the Kraus operators for a pair of interacting qubits, while the strength of the interaction is arbitrary. One of the qubits is subjected to the x-projection spin measurement. The obtained results are applied to calculate the dynamics of the entanglement in the qubits system. We obtain the loss of the correlations in the finite time interval; the stronger the inter-qubit interaction, the longer lasting entanglement in the system.

  1. OCCUPATIONAL EXPOSURE OF NMR SPECTROMETRISTS TO STATIC AND RADIOFREQUENCY FIELDS.

    PubMed

    Berlana, Tania; Úbeda, Alejandro

    2017-12-01

    Occupational exposure to static and radiofrequency fields emitted by nuclear magnetic resonance spectrometers was assessed through systematic field metering during operation of 19 devices in nine research centers. Whereas no measurable levels of radiofrequency radiation were registered outside the spectrometers, significant exposure to static field was detected, with maximum values recorded at the user's hand (B = 683.00 mT) and head-thorax (B = 135.70 mT) during spectrometer manipulation. All values were well below the exposure limits set by the European standard for workers protection against the effects of acute field exposure only. As for potential effects of chronic exposure, waiting for more complete knowledge, adoption of technical and operational strategies for exposure minimizing is advisable. In this respect, the data revealed that compared with standard magnetic shielding, ultrashield technology allows a 20-65-fold reduction of the field strength received by the operator. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Modelling Concentrating Solar Power with Thermal Energy Storage for Integration Studies (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hummon, M.; Jorgenson, J.; Denholm, P.

    2013-10-01

    Concentrating solar power with thermal energy storage (CSP-TES) can provide multiple benefits to the grid, including low marginal cost energy and the ability to levelize load, provide operating reserves, and provide firm capacity. It is challenging to properly value the integration of CSP because of the complicated nature of this technology. Unlike completely dispatchable fossil sources, CSP is a limited energy resource, depending on the hourly and daily supply of solar energy. To optimize the use of this limited energy, CSP-TES must be implemented in a production cost model with multiple decision variables for the operation of the CSP-TES plant.more » We develop and implement a CSP-TES plant in a production cost model that accurately characterizes the three main components of the plant: solar field, storage tank, and power block. We show the effect of various modelling simplifications on the value of CSP, including: scheduled versus optimized dispatch from the storage tank and energy-only operation versus co-optimization with ancillary services.« less

  3. Modelling Concentrating Solar Power with Thermal Energy Storage for Integration Studies: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hummon, M.; Denholm, P.; Jorgenson, J.

    2013-10-01

    Concentrating solar power with thermal energy storage (CSP-TES) can provide multiple benefits to the grid, including low marginal cost energy and the ability to levelize load, provide operating reserves, and provide firm capacity. It is challenging to properly value the integration of CSP because of the complicated nature of this technology. Unlike completely dispatchable fossil sources, CSP is a limited energy resource, depending on the hourly and daily supply of solar energy. To optimize the use of this limited energy, CSP-TES must be implemented in a production cost model with multiple decision variables for the operation of the CSP-TES plant.more » We develop and implement a CSP-TES plant in a production cost model that accurately characterizes the three main components of the plant: solar field, storage tank, and power block. We show the effect of various modelling simplifications on the value of CSP, including: scheduled versus optimized dispatch from the storage tank and energy-only operation versus co-optimization with ancillary services.« less

  4. Composite operators in the hopping parameter expansion in the free quark model

    NASA Astrophysics Data System (ADS)

    Kunszt, Z.

    1983-11-01

    I have calculated hopping parameter series of meson and baryon propagators up to O(K32) in the Wilson formulation of the free quark model. The position of branch point singularities has been found with the help of Padé approximants. The values of the position of the singularities in K agreed with the exact values within 1-2% in case of mesons and 4-5% in case of baryons. It is argued that in QCD at the cross-over region the systematic errors of the method must be even smaller. Part of this work has been done while the author was visiting the Rutherford and Appleton Laboratories, UK.

  5. Post-operative monitoring of free muscle transfers by Laser Doppler Imaging: A prospective study.

    PubMed

    Tschumi, Christian; Seyed Jafari, S Morteza; Rothenberger, Jens; Van de Ville, Dimitri; Keel, Marius; Krause, Fabian; Shafighi, Maziar

    2015-10-01

    Despite different existing methods, monitoring of free muscle transfer is still challenging. In the current study we evaluated our clinical setting regarding monitoring of such tissues, using a recent microcirculation-imaging camera (EasyLDI) as an additional tool for detection of perfusion incompetency. This study was performed on seven patients with soft tissue defect, who underwent reconstruction with free gracilis muscle. Beside standard monitoring protocol (clinical assessment, temperature strips, and surface Doppler), hourly EasyLDI monitoring was performed for 48 hours. Thereby a baseline value (raised flap but connected to its vascular bundle) and an ischaemia perfusion value (completely resected flap) were measured at the same point. The mean age of the patients, mean baseline value, ischaemia value perfusion were 48.00 ± 13.42 years, 49.31 ± 17.33 arbitrary perfusion units (APU), 9.87 ± 4.22 APU, respectively. The LDI measured values in six free muscle transfers were compatible with hourly standard monitoring protocol, and normalized LDI values significantly increased during time (P < 0.001, r = 0.412). One of the flaps required a return to theatre 17 hours after the operation, where an unsalvageable flap loss was detected. All normalized LDI values of this flap were under the ischaemia perfusion level and the trend was significantly descending during time (P < 0.001, r = -0.870). Due to the capability of early detection of perfusion incompetency, LDI may be recommended as an additional post-operative monitoring device for free muscle flaps, for early detection of suspected failing flaps and for validation of other methods. © 2015 Wiley Periodicals, Inc.

  6. Benefit of Complete State Monitoring For GPS Realtime Applications With Geo++ Gnsmart

    NASA Astrophysics Data System (ADS)

    Wübbena, G.; Schmitz, M.; Bagge, A.

    Today, the demand for precise positioning at the cm-level in realtime is worldwide growing. An indication for this is the number of operational RTK network installa- tions, which use permanent reference station networks to derive corrections for dis- tance dependent GPS errors and to supply corrections to RTK users in realtime. Gen- erally, the inter-station distances in RTK networks are selected at several tens of km in range and operational installations cover areas of up to 50000 km x km. However, the separation of the permanent reference stations can be increased to sev- eral hundred km, while a correct modeling of all error components is applied. Such networks can be termed as sparse RTK networks, which cover larger areas with a reduced number of stations. The undifferenced GPS observable is best suited for this task estimating the complete state of a permanent GPS network in a dynamic recursive Kalman filter. A rigorous adjustment of all simultaneous reference station data is re- quired. The sparse network design essentially supports the state estimation through its large spatial extension. The benefit of the approach and its state modeling of all GPS error components is a successful ambiguity resolution in realtime over long distances. The above concepts are implemented in the operational GNSMART (GNSS State Monitoring and Representation Technique) software of Geo++. It performs a state monitoring of all error components at the mm-level, because for RTK networks this accuracy is required to sufficiently represent the distance dependent errors for kine- matic applications. One key issue of the modeling is the estimation of clocks and hard- ware delays in the undifferenced approach. This pre-requisite subsequently allows for the precise separation and modeling of all other error components. Generally most of the estimated parameters are considered as nuisance parameters with respect to pure positioning tasks. As the complete state vector of GPS errors is available in a GPS realtime network, additional information besides position can be derived e.g. regional precise satellite clocks, orbits, total ionospheric electron content, tropospheric water vapor distribution, and also dynamic reference station movements. The models of GNSMART are designed to work with regional, continental or even global data. Results from GNSMART realtime networks with inter-station distances of several hundred km are presented to demonstrate the benefits of the operational implemented concepts.

  7. Quantitative Value of Aldosterone-Renin Ratio for Detection of Aldosterone-Producing Adenoma: The Aldosterone-Renin Ratio for Primary Aldosteronism (AQUARR) Study.

    PubMed

    Maiolino, Giuseppe; Rossitto, Giacomo; Bisogni, Valeria; Cesari, Maurizio; Seccia, Teresa Maria; Plebani, Mario; Rossi, Gian Paolo

    2017-05-21

    Current guidelines recommend use of the aldosterone-renin ratio (ARR) for the case detection of primary aldosteronism followed by confirmatory tests to exclude false-positive results from further diagnostic workup. We investigated the hypothesis that this could be unnecessary in patients with a high ARR value if the quantitative information carried by the ARR is taken into due consideration. We interrogated 2 large data sets of prospectively collected patients studied with the same predefined protocol, which included the captopril challenge test. We used an unambiguous diagnosis of aldosterone-producing adenoma as reference index. We also assessed whether the post-captopril ARR and plasma aldosterone concentration fall furnished a diagnostic gain over baseline ARR values. We found that the false-positive rate fell exponentially, and, conversely, the specificity increased with rising ARR values. At receiver operating characteristics curves and diagnostic odds ratio analysis, the high baseline ARR values implied very high positive likelihood ratio and diagnostic odds ratio values. The baseline and post-captopril ARR showed similar diagnostic accuracy (area under the receiver operating characteristics curve) in both the exploratory and validation cohorts, indicating lack of diagnostic gain with this confirmatory test (between-area under the curve difference, 0.005; 95% CI, -0.031 to 0.040; P =0.7 for comparison, and 0.05; 95% CI, -0.061 to 0.064; P =0.051 for comparison, respectively). These results indicate that the ARR conveys key quantitative information that, if properly used, can simplify the diagnostic workup, resulting in saving of money and resources. This can offer the chance of diagnosis and ensuing adrenalectomy to a larger number of hypertensive patients, ultimately resulting in better control of blood pressure. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  8. Large angle magnetic suspension test fixture

    NASA Technical Reports Server (NTRS)

    Britcher, Colin P.

    1993-01-01

    Progress made under the subject grant in the period from 1 Nov. 1992 to 31 May 1993 is presented. The research involves the continued development of the Large Angle Magnetic Suspension Test Fixture (LAMSTF) and also the recommissioning of an additional piece of exisiting hardware. During the period in question, the initial configuration of LAMSTF was completed and made routinely and reliably operational. A digital phase advance controller was completed and documented. The goal of a controlled 360 deg rotation was achieved. Work started on the recommissioning of the Annular Suspension and Pointing System (ASPS). Work completed during the report period included: modeling; position sensing; controller; support of the Second International Symposium on Magnetic Suspension Technology; and recommissioning of the Annular Suspension and Pointing System.

  9. Effects of positive end-expiratory pressure on arthroscopic shoulder surgery under general anesthesia.

    PubMed

    Ersoy, Ayşın; Çakırgöz, Mensure; Ervatan, Zekeriya; Kıran, Özlem; Türkmen, Aygen; Esenyel, Cem Zeki

    2016-01-01

    Our study is a prospective, randomized study on patients undergoing arthroscopic shoulder surgery in the beach-chair position to evaluate the effects of positive end-expiratory pressure (PEEP) on hemodynamic stability, providing a bloodless surgical field and surgical satisfaction. Fifty patients were divided into two groups. Group I (n=25) had zero end-expiratory pressure (ZEEP) administered under general anesthesia, and group II (n=25) had +5 PEEP administered. During surgery, intraarticular hemorrhage and surgical satisfaction were evaluated on a scale of 0-10. During surgery, at the 5th, 30th, 60th, and 90th minutes and at the end of surgery, heart rate, mean arterial pressure (MAP), and positive inspiratory pressure were recorded. At the end of the surgery, the amount of bleeding and duration of the operation were recorded. In group I, the duration of operation and amount of bleeding were found to be significantly greater than those in group II (p<0.05). The surgical satisfaction score and clarity of the surgical field were found to be significantly lower in group I than in group II (p<0.05). MAP values in group I were significantly lower than those in group II. The SPO² values in group I were significantly lower than those in group II. Adding PEEP to the ventilation parameters of arthroscopic shoulder surgery in the beach-chair position reduces the amount of hemorrhage in the surgical field and thus increases surgical satisfaction without requiring the creation of controlled hypotension.

  10. Value of stress ultrasound for the diagnosis of chronic ankle instability compared to manual anterior drawer test, stress radiography, magnetic resonance imaging, and arthroscopy.

    PubMed

    Cho, Jae Ho; Lee, Doo Hyung; Song, Hyung Keun; Bang, Joon Young; Lee, Kyung Tai; Park, Young Uk

    2016-04-01

    Clinicians frequently diagnose chronic ankle instability using the manual anterior drawer test and stress radiography. However, both examinations can yield incorrect results and do not reveal the extent of ankle instability. Stress ultrasound has been reported to be a new diagnostic tool for the diagnosis of chronic ankle instability. The purpose of this study was to assess the diagnostic value of stress ultrasound for chronic ankle instability compared to the manual anterior drawer test, stress radiography, magnetic resonance imaging (MRI), and arthroscopy. Twenty-eight consecutive patients who underwent ankle arthroscopy and subsequent modified Broström repair for treatment of chronic ankle instability were included. The arthroscopic findings were used as the reference standard. A standardized physical examination (manual anterior drawer test), stress radiography, MRI, and stress ultrasound were performed to assess the anterior talofibular ligament (ATFL) prior to operation. Ultrasound images were taken in the resting position and the maximal anterior drawer position. Grade 3 lateral instability was verified arthroscopically in all 28 cases with a clinical diagnosis (100%). Twenty-two cases showed grade III instability on the manual anterior drawer test (78.6%). Twenty-four cases displayed anterior translation exceeding 5 mm on stress radiography (86%), and talar tilt angle exceeded 15° in three cases (11 %). Nineteen cases displayed a partial chronic tear (change in thickness or signal intensity), and nine cases displayed complete tear on MRI (100%). Lax and wavy ATFL was evident on stress ultrasound in all cases (100 %). The mean value of the ATFL length was 2.8 ± 0.3 cm for the stressed condition and 2.1 ± 0.2 cm for the resting condition (p < 0.001). Stress ultrasound may be useful for the diagnosis of chronic ankle instability in addition to the manual anterior drawer test and stress radiography. III.

  11. A comparative analysis of salivary factors and maxillary denture retention in different arch forms: An in vivo study.

    PubMed

    Shekhar, Abhishek; Das, Samiran; Bhattacharyya, Jayanta; Goel, Preeti; Majumdar, Sayan; Ghosh, Soumitra

    2018-01-01

    This study aims to find the effect of change in different salivary factors before and after complete denture insertion and to measure the maxillary denture retention in different arch forms. Thirty completely edentulous individuals (10 each of square, tapered, and ovoid arch form of maxilla) belonging to the age group of 40-70 years were selected. Salivary factors (flow, density, pH, viscosity, and total protein) were evaluated before and after denture insertion. Retention of maxillary denture was measured in all the different arch forms. Student's independent sample's t -test was applied. The correlation was analyzed by Pearson's correlation analysis. While mean flow rate and pH of saliva increased, mean viscosity, total protein, and density of saliva decreased after maxillary complete denture insertion. A positive correlation was found between retention and total maxillary basal surface area. Retention value was found to be greatest in square type and least in tapered type. Complete denture acts as a mechanical stimulant thus increasing flow rate and pH immediately after complete denture insertion. Density, total protein, and viscosity of saliva decreased after complete denture insertion which may be due to increase in water content of saliva. The retention of maxillary complete denture does not seem to depend on the rate of change of the salivary factors, before and after complete denture insertion. Total basal surface area and maxillary denture retention values were highest in square arch form and least in tapered arch form.

  12. Empirical analysis on future-cash arbitrage risk with portfolio VaR

    NASA Astrophysics Data System (ADS)

    Chen, Rongda; Li, Cong; Wang, Weijin; Wang, Ze

    2014-03-01

    This paper constructs the positive arbitrage position by alternating the spot index with Chinese Exchange Traded Fund (ETF) portfolio and estimating the arbitrage-free interval of futures with the latest trade data. Then, an improved Delta-normal method was used, which replaces the simple linear correlation coefficient with tail dependence correlation coefficient, to measure VaR (Value-at-risk) of the arbitrage position. Analysis of VaR implies that the risk of future-cash arbitrage is less than that of investing completely in either futures or spot market. Then according to the compositional VaR and the marginal VaR, we should increase the futures position and decrease the spot position appropriately to minimize the VaR, which can minimize risk subject to certain revenues.

  13. Dynamical insurance models with investment: Constrained singular problems for integrodifferential equations

    NASA Astrophysics Data System (ADS)

    Belkina, T. A.; Konyukhova, N. B.; Kurochkin, S. V.

    2016-01-01

    Previous and new results are used to compare two mathematical insurance models with identical insurance company strategies in a financial market, namely, when the entire current surplus or its constant fraction is invested in risky assets (stocks), while the rest of the surplus is invested in a risk-free asset (bank account). Model I is the classical Cramér-Lundberg risk model with an exponential claim size distribution. Model II is a modification of the classical risk model (risk process with stochastic premiums) with exponential distributions of claim and premium sizes. For the survival probability of an insurance company over infinite time (as a function of its initial surplus), there arise singular problems for second-order linear integrodifferential equations (IDEs) defined on a semiinfinite interval and having nonintegrable singularities at zero: model I leads to a singular constrained initial value problem for an IDE with a Volterra integral operator, while II model leads to a more complicated nonlocal constrained problem for an IDE with a non-Volterra integral operator. A brief overview of previous results for these two problems depending on several positive parameters is given, and new results are presented. Additional results are concerned with the formulation, analysis, and numerical study of "degenerate" problems for both models, i.e., problems in which some of the IDE parameters vanish; moreover, passages to the limit with respect to the parameters through which we proceed from the original problems to the degenerate ones are singular for small and/or large argument values. Such problems are of mathematical and practical interest in themselves. Along with insurance models without investment, they describe the case of surplus completely invested in risk-free assets, as well as some noninsurance models of surplus dynamics, for example, charity-type models.

  14. A prospective cohort study on the clinical utility of second trimester mean arterial blood pressure in the prediction of late-onset preeclampsia among Nigerian women.

    PubMed

    Udenze, I C; Arikawe, A P; Makwe, C C; Olowoselu, O F

    2017-06-01

    Early detection of preeclampsia will help reduce the morbidities and mortalities associated with the disorder. Late-onset preeclampsia was the predominant presentation in this cohort. The search for biomarkers for predicting preeclampsia is still ongoing. Mean arterial blood pressure (MABP), which has the advantage of presenting a single cutoff value compared with the use of systolic and diastolic blood pressure measurements, merits evaluation. The study aims to evaluate the clinical utility of second trimester MABP in the prediction of preeclampsia. This was a prospective cohort study of 155 normotensive, nonproteinuric pregnant women without prior history of gestational hypertension. The women were booked patients attending the antenatal clinic at the Lagos University Teaching Hospital and were all in their second trimesters of pregnancy. The outcome measures were systolic blood pressure, diastolic blood pressure, and MABP. The end point of the study was the development of preeclampsia. The diagnosis of preeclampsia was made by the attending obstetrician. The data were analyzed using the IBM SPSS statistical software. Statistical significance was set at P < 0.05. One hundred and fifty-five pregnant women participated in the study. Eleven (7.1%) of the women developed preeclampsia after 34 weeks gestation and 144 (92.9%) had normal pregnancy. The mean gestational age at the time of assessment was 18.88 ± 3.15 weeks with a range of 14 weeks to 27 completed weeks. There was a statistically significant increase in the systolic blood pressure, diastolic blood pressure, and MABP values in the group of women who later developed preeclampsia, P = 0.005, 0.001, and <0.001, respectively. At a false-positive rate of 10%, MABP value of 88.33 mmHg predicted preeclampsia with a specificity of 90% and a sensitivity of 45.5%, P <0.05. The area under the receiver-operative characteristics curve (AUC) was 0.732 (95% confidence interval, 0.544-0.919, P = 0.011). The negative predictive value (NPV) was 88.88% and the positive predictive value (PPV) was 45.45%, P < 0.05. At an MABP cutoff of 88.33 mmHg, preeclampsia was predicted with a relative risk of 4.44 and a positive likelihood ratio of 6.46, P < 0.05. With an AUC of 0.732, MABP performed moderately (considering that excellent performance has an AUC of 1.0) in the prediction of late-onset preeclampsia in Nigerian women. Its high NPV suggests a strong ability to rule out preeclampsia and help to appropriate management.

  15. Prevalence, cause, and location of palatal fistula in operated complete unilateral cleft lip and palate: retrospective study.

    PubMed

    de Agostino Biella Passos, Vivian; de Carvalho Carrara, Cleide Felício; da Silva Dalben, Gisele; Costa, Beatriz; Gomide, Marcia Ribeiro

    2014-03-01

    To evaluate the prevalence of fistulas after palate repair and analyze their location and association with possible causal factors. Retrospective analysis of patient records and evaluation of preoperative initial photographs. Tertiary craniofacial center. Five hundred eighty-nine individuals with complete unilateral cleft lip and palate that underwent palate repair at the age of 12 to 36 months by the von Langenbeck technique, in a single stage, by the plastic surgery team of the hospital, from January 2003 to July 2007. The cleft width was visually classified by a single examiner as narrow, regular, or wide. The following regions of the palate were considered for the location: anterior, medium, transition (between hard and soft palate), and soft palate. Descriptive statistics and analysis of association between the occurrence of fistula and the different parameters were evaluated. Palatal fistulas were observed in 27% of the sample, with a greater proportion at the anterior region (37.11%). The chi-square statistical test revealed statistically significant association (P ≤ .05) between the fistulas and initial cleft width (P = .0003), intraoperative problems (P = .0037), and postoperative problems (P = .00002). The prevalence of palatal fistula was similar to mean values reported in the literature. Analysis of causal factors showed a positive association between palatal fistulas with wide and regular initial cleft width and intraoperative and postoperative problems. The anterior region presented the greatest occurrence of fistulas.

  16. Effectiveness of Unmanned Surface Vehicles in Anti-submarine Warfare with the Goal of Protecting a High Value Unit

    DTIC Science & Technology

    2015-06-01

    headquarters Services , Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302, and...are positioned on the outer ASW screen to protect an HVU from submarine attacks. This baseline scenario provides a standardized benchmark on current...are positioned on the outer ASW screen to protect an HVU from submarine attacks. This baseline scenario provides us a standardized benchmark . In the

  17. A Balanced Scorecard With Strategy Map: Measuring the Value of a Nursing Sabbatical.

    PubMed

    Embree, Jennifer L; Swenty, Constance F; Schaar, Gina

    2015-01-01

    Seasoned nurses frequently resign from their positions due to burnout. An innovative idea that could support nurse retention is nurse sabbaticals. Balanced scorecards with strategy maps can display financial benefit, positive customer experience, and operational and human capital development required to initiate and sustain a professional nurse sabbatical. A balanced scorecard with strategy map is an effective tool that demonstrates connection between the organizational mission and the outcomes of a nurse sabbatical program.

  18. System Administrator for LCS Development Sets

    NASA Technical Reports Server (NTRS)

    Garcia, Aaron

    2013-01-01

    The Spaceport Command and Control System Project is creating a Checkout and Control System that will eventually launch the next generation of vehicles from Kennedy Space Center. KSC has a large set of Development and Operational equipment already deployed in several facilities, including the Launch Control Center, which requires support. The position of System Administrator will complete tasks across multiple platforms (Linux/Windows), many of them virtual. The Hardware Branch of the Control and Data Systems Division at the Kennedy Space Center uses system administrators for a variety of tasks. The position of system administrator comes with many responsibilities which include maintaining computer systems, repair or set up hardware, install software, create backups and recover drive images are a sample of jobs which one must complete. Other duties may include working with clients in person or over the phone and resolving their computer system needs. Training is a major part of learning how an organization functions and operates. Taking that into consideration, NASA is no exception. Training on how to better protect the NASA computer infrastructure will be a topic to learn, followed by NASA work polices. Attending meetings and discussing progress will be expected. A system administrator will have an account with root access. Root access gives a user full access to a computer system and or network. System admins can remove critical system files and recover files using a tape backup. Problem solving will be an important skill to develop in order to complete the many tasks.

  19. Horizontal technology helps spark Louisiana`s Austin chalk trend

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koen, A.D.

    1996-04-29

    A handful of companies paced by some of the most active operators in the US are pressing the limits of horizontal technology to ramp up Cretaceous Austin chalk exploration and development (E and D) across Louisiana. Companies find applications in Louisiana for lessons learned drilling horizontal wells to produce chalk intervals in Texas in Giddings, Pearsall, and Brookeland fields. Continuing advances in horizontal well technology are helping operators deal with deeper, hotter reservoirs in more complex geological settings that typify the chalk in Louisiana. Better horizontal drilling, completion, formation evaluation, and stimulation techniques have enabled operators to produce oil andmore » gas from formations previously thought to be uneconomical. Most of the improved capabilities stem from better horizontal tools. Horizontal drilling breakthroughs include dual powered mud motors and retrievable whipstocks, key links in the ability to drill wells with more than one horizontal lateral. Better geosteering tools have enabled operators to maintain horizontal wellbores in desired intervals by signaling bit positions downhole while drilling. This paper reviews the technology and provides a historical perspective on the various drilling programs which have been completed in this trend. It also makes predictions on future drilling successes.« less

  20. The Application of Voltage Transformer Simulator in Electrical Test Training

    NASA Astrophysics Data System (ADS)

    Li, Nan; Zhang, Jun; Chai, Ziqi; Wang, Jingpeng; Yang, Baowei

    2018-02-01

    The voltage transformer test is an important means to monitor its operating state. The accuracy and reliability of the test data is directly related to the test skill level of the operator. However, the risk of test instruments damage, equipment being tested damage and electric shock in operator is caused by improper operation when training the transformer test. In this paper, a simulation device of voltage transformer is set up, and a simulation model is built for the most common 500kV capacitor voltage transformer (CVT), the simulation model can realize several test items of CVT by combing with teaching guidance platform, simulation instrument, complete set of system software and auxiliary equipment in Changchun. Many successful applications show that the simulation device has good practical value and wide application prospect.

  1. Evaluation of predictive capacities of biomarkers based on research synthesis.

    PubMed

    Hattori, Satoshi; Zhou, Xiao-Hua

    2016-11-10

    The objective of diagnostic studies or prognostic studies is to evaluate and compare predictive capacities of biomarkers. Suppose we are interested in evaluation and comparison of predictive capacities of continuous biomarkers for a binary outcome based on research synthesis. In analysis of each study, subjects are often classified into two groups of the high-expression and low-expression groups according to a cut-off value, and statistical analysis is based on a 2 × 2 table defined by the response and the high expression or low expression of the biomarker. Because the cut-off is study specific, it is difficult to interpret a combined summary measure such as an odds ratio based on the standard meta-analysis techniques. The summary receiver operating characteristic curve is a useful method for meta-analysis of diagnostic studies in the presence of heterogeneity of cut-off values to examine discriminative capacities of biomarkers. We develop a method to estimate positive or negative predictive curves, which are alternative to the receiver operating characteristic curve based on information reported in published papers of each study. These predictive curves provide a useful graphical presentation of pairs of positive and negative predictive values and allow us to compare predictive capacities of biomarkers of different scales in the presence of heterogeneity in cut-off values among studies. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. The influence of prototype fidelity and aesthetics of design in usability tests: effects on user behaviour, subjective evaluation and emotion.

    PubMed

    Sauer, Juergen; Sonderegger, Andreas

    2009-07-01

    An empirical study examined the impact of prototype fidelity on user behaviour, subjective user evaluation and emotion. The independent factors of prototype fidelity (paper prototype, computer prototype, fully operational appliance) and aesthetics of design (high vs. moderate) were varied in a between-subjects design. The 60 participants of the experiment were asked to complete two typical tasks of mobile phone usage: sending a text message and suppressing a phone number. Both performance data and a number of subjective measures were recorded. The results suggested that task completion time may be overestimated when a computer prototype is being used. Furthermore, users appeared to compensate for deficiencies in aesthetic design by overrating the aesthetic qualities of reduced fidelity prototypes. Finally, user emotions were more positively affected by the operation of the more attractive mobile phone than by the less appealing one.

  3. Working with Value: Industry-Specific Approaches to Workforce Development. A Synthesis of Findings.

    ERIC Educational Resources Information Center

    Rademacher, Ida, Ed.

    Multi-year applied research studied operations and outcomes of six employment initiatives that developed industry-based approaches to workforce development. Findings from the longitudinal survey of 732 individuals indicated participants in sectoral programs improved their position within local labor markets; increased wages, hours worked, and…

  4. Behavioral Treatment of Hysterical Coughing and Mutism: A Case Study

    ERIC Educational Resources Information Center

    Munford, Paul R.; And Others

    1976-01-01

    This case study demonstrates the value of conceptualizing functional somatic disorders as operants. The subject, an adolescent girl, diagnosed as having a "hysterical neurosis," manifested the symptoms of incessant coughing and mutism. The cough and mutism were treated by extinction and shaping, respectively. Positive results were obtained.…

  5. The insertional torque of a pedicle screw has a positive correlation with bone mineral density in posterior lumbar pedicle screw fixation.

    PubMed

    Lee, J H; Lee, J-H; Park, J W; Shin, Y H

    2012-01-01

    In patients with osteoporosis there is always a strong possibility that pedicle screws will loosen. This makes it difficult to select the appropriate osteoporotic patient for a spinal fusion. The purpose of this study was to determine the correlation between bone mineral density (BMD) and the magnitude of torque required to insert a pedicle screw. To accomplish this, 181 patients with degenerative disease of the lumbar spine were studied prospectively. Each underwent dual-energy x-ray absorptiometry (DEXA) and intra-operative measurement of the torque required to insert each pedicle screw. The levels of torque generated in patients with osteoporosis and osteopenia were significantly lower than those achieved in normal patients. Positive correlations were observed between BMD and T-value at the instrumented lumbar vertebrae, mean BMD and mean T-value of the lumbar vertebrae, and mean BMD and mean T-value of the proximal femur. The predictive torque (Nm) generated during pedicle screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar vertebrae)], as measured by linear regression analysis. The positive correlation between BMD and the maximum torque required to insert a pedicle screw suggests that pre-operative assessment of BMD may be useful in determining the ultimate strength of fixation of a device, as well as the number of levels that need to be fixed with pedicle screws in patients who are suspected of having osteoporosis.

  6. Technical Suitability and Static Stability of Sungkur Fishing Boats for Fish and Shrimp Catching

    NASA Astrophysics Data System (ADS)

    Rusmilyansari; Rosadi, E.; Iriansyah

    2017-10-01

    Sungkur fishing gear is operated actively on one the side of fishing boat, which requires technical suitability and fishing gear stability to ensure success in fish catching. This is a case study which aimed to analyze some technical issues related to the boat, boat’s hydrostatic parameters, and the boat’s stability. The data were collected though observation, measuring the boat to obtain the offset table. The data were analyzed numerically and descriptively. The data were processed with technical formula, Microsoft Office’s Excel software, graphic display, minitab, statistical data processing, and maxsurf program. The research results showed that: (1) the sungkur fishing boat dimensional ratio L/B (6.47 - 7.00); L/D (10.90 - 11.20) and B/D (1.60 - 1.668) is within the range value of Indonesian fishing boats suitable to operate the fishing gear by towing or dragging. However, during fish catching operation, there have been problems in a hydrodynamic force due to the fishing gear movement, which affect the fish catching efficiency. (2) The boat’s coefficient of fineness is in the fine type shape; the displacement on each waterline has increased; the loads of the boat are getting larger following the increase of waterline from one to five; this is also shown from the increasing midship area value. Ton per centimeter immersion to change wl 1 by 1 cm needs 0.04 tons of weight. (3) Sungkur fishing boat have a good static stability, which is proven by the positive value of angle of maximum GZ by 79.1 - 83.6. In other words, the boat has the ability to return to its original position after tilting; however, stability dynamics happens because fishing gear operation are located on just one side of boat.

  7. Patient Centered Outcomes Assessment of Retreatment and Endodontic Microsurgery Using CBCT Volumetric Analysis

    DTIC Science & Technology

    2018-11-09

    Retreatment and EMS were completed using a dental operating microscope (Zeiss OPMJ PROergo) and contemporary materials and techniques. Retreatrnent...paralleling technique and external cone positioning device (XCP) using size 2 digital sensors (Kodak RVG 6100). A dental x-ray machine (Planmeca...EMS and retreatment were calculated. Examiners used MiPACS dental enterprise viewer (LEAD Technologies Inc, Charlotte, NC) to interpret randomized

  8. Soldier Performance in a Moving Command Vehicle Under Manned, Teleoperated, and Teleoperated Cruise Control Modes Under Day and Night Conditions

    DTIC Science & Technology

    2013-05-01

    official Department of the Army position unless so designated by other authorized documents. Citation of manufacturer’s or trade names does not... designed to examine these modes of operation, comparing the subjective workload, stress, and motion sickness as well as course completion time...8  3.5  Design and Analysis ........................................................................................................9

  9. Convergence of damped inertial dynamics governed by regularized maximally monotone operators

    NASA Astrophysics Data System (ADS)

    Attouch, Hedy; Cabot, Alexandre

    2018-06-01

    In a Hilbert space setting, we study the asymptotic behavior, as time t goes to infinity, of the trajectories of a second-order differential equation governed by the Yosida regularization of a maximally monotone operator with time-varying positive index λ (t). The dissipative and convergence properties are attached to the presence of a viscous damping term with positive coefficient γ (t). A suitable tuning of the parameters γ (t) and λ (t) makes it possible to prove the weak convergence of the trajectories towards zeros of the operator. When the operator is the subdifferential of a closed convex proper function, we estimate the rate of convergence of the values. These results are in line with the recent articles by Attouch-Cabot [3], and Attouch-Peypouquet [8]. In this last paper, the authors considered the case γ (t) = α/t, which is naturally linked to Nesterov's accelerated method. We unify, and often improve the results already present in the literature.

  10. Time operators in stroboscopic wave-packet basis and the time scales in tunneling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bokes, P.

    2011-03-15

    We demonstrate that the time operator that measures the time of arrival of a quantum particle into a chosen state can be defined as a self-adjoint quantum-mechanical operator using periodic boundary conditions and applied to wave functions in energy representation. The time becomes quantized into discrete eigenvalues; and the eigenstates of the time operator, i.e., the stroboscopic wave packets introduced recently [Phys. Rev. Lett. 101, 046402 (2008)], form an orthogonal system of states. The formalism provides simple physical interpretation of the time-measurement process and direct construction of normalized, positive definite probability distribution for the quantized values of the arrival time.more » The average value of the time is equal to the phase time but in general depends on the choice of zero time eigenstate, whereas the uncertainty of the average is related to the traversal time and is independent of this choice. The general formalism is applied to a particle tunneling through a resonant tunneling barrier in one dimension.« less

  11. Engaging in Work Even When It Is Meaningless: Positive Affective Disposition and Meaningful Work Interact in Relation to Work Engagement

    ERIC Educational Resources Information Center

    Steger, Michael F.; Littman-Ovadia, Hadassah; Miller, Michal; Menger, Lauren; Rothmann, Sebastiaan

    2013-01-01

    The central aim of the present study was to assess the predictive value of affective disposition and meaningful work on employee engagement. Specifically, it was proposed that meaningful work moderates the relationship between affective disposition and engagement. Questionnaires were completed by 252 white-collar employees, working in a variety of…

  12. What's the Best Course? Evidence from Alumni on the Value of Business Presentations Preparation

    ERIC Educational Resources Information Center

    Marcel, Mary

    2015-01-01

    Developing effective presentation skills is a core competence skill for business communicators. Self-report data from a survey of 1,610 2- to 12-year business alumni show that 37.1% present monthly and 27.9% present weekly in their current positions. Alumni who completed a general public speaking course, or both managerial communication and a…

  13. Wigner tomography of multispin quantum states

    NASA Astrophysics Data System (ADS)

    Leiner, David; Zeier, Robert; Glaser, Steffen J.

    2017-12-01

    We study the tomography of multispin quantum states in the context of finite-dimensional Wigner representations. An arbitrary operator can be completely characterized and visualized using multiple shapes assembled from linear combinations of spherical harmonics [A. Garon, R. Zeier, and S. J. Glaser, Phys. Rev. A 91, 042122 (2015), 10.1103/PhysRevA.91.042122]. We develop a general methodology to experimentally recover these shapes by measuring expectation values of rotated axial spherical tensor operators and provide an interpretation in terms of fictitious multipole potentials. Our approach is experimentally demonstrated for quantum systems consisting of up to three spins using nuclear magnetic resonance spectroscopy.

  14. Implementation of an adaptive controller for the startup and steady-state running of a biomethanation process operated in the CSTR mode.

    PubMed

    Renard, P; Van Breusegem, V; Nguyen, M T; Naveau, H; Nyns, E J

    1991-10-20

    An adaptive control algorithm has been implemented on a biomethanation process to maintain propionate concentration, a stable variable, at a given low value, by steering the dilution rate. It was thereby expected to ensure the stability of the process during the startup and during steady-state running with an acceptable performance. The methane pilot reactor was operated in the completely mixed, once-through mode and computer-controlled during 161 days. The results yielded the real-life validation of the adaptive control algorithm, and documented the stability and acceptable performance expected.

  15. Respiratory protective device design using control system techniques

    NASA Technical Reports Server (NTRS)

    Burgess, W. A.; Yankovich, D.

    1972-01-01

    The feasibility of a control system analysis approach to provide a design base for respiratory protective devices is considered. A system design approach requires that all functions and components of the system be mathematically identified in a model of the RPD. The mathematical notations describe the operation of the components as closely as possible. The individual component mathematical descriptions are then combined to describe the complete RPD. Finally, analysis of the mathematical notation by control system theory is used to derive compensating component values that force the system to operate in a stable and predictable manner.

  16. Screening for attention-deficit/hyperactivity disorder in borderline personality disorder.

    PubMed

    Weibel, Sébastien; Nicastro, Rosetta; Prada, Paco; Cole, Pierre; Rüfenacht, Eva; Pham, Eléonore; Dayer, Alexandre; Perroud, Nader

    2018-01-15

    A valid screening instrument is needed to detect attention-deficit/hyperactivity disorder (ADHD) in treatment-seeking borderline personality disorder (BPD) patients. We aimed to test the performance of the widely-used Adult ADHD Self-Report Scale v1.1 screener (ASRS-v1.1). 317 BPD subjects were systematically assessed for comorbid ADHD and completed the ASRS-v1.1. 79 BPD patients also completed the Wender Utah Rating Scale (WURS-25). The prevalence of adult ADHD was of 32.4%. The overall positive predictive value of the ASRS-v1.1 was of 38.5%, the negative predictive value 77.0%, the sensitivity 72.8%, and the specificity 43.9%. Combining WURS-25 and ASRS-v1.1 improved sensitivity to 81.8% and specificity to 59.6%. Cross-sectional study on treatment-seeking patients. We found a high prevalence of ADHD using structured interviews. The ASRS-v1.1 was not a sensitive screener for identifying possible ADHD cases in a BPD population, with a high number of false positives. When combined with the WURS-25, it offered improved screening. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Application value of different transformation zone types and its genetic relationship with high-risk HPV type in diagnosis and therapy of cervical disease.

    PubMed

    Chen, Yan; Zhou, Jia-De

    2015-01-01

    This study aims to discuss the influence of different types of transformation zone (TZ) on positive surgical margin of loop electrosurgical excision procedure (LEEP) and the significance of infection of different genetic high-risk HPV for cervical intraepithelial neoplasm. The clinical data of patients who had CIN2+ and received LEEP during January to December 2013 was investigated. The conditions of positive surgical margin of patients of different transformation zone (type I, II, III) were analyzed. The clinical high-risk types of HPV were divided into three groups, including A5/6, A7 and A9, compared with the pathological conditions of pre-operation and post-operation of the patients in respective group. The results indicated that type III transformation zone is more likely to cause positive cutting margin. For CIN2+ patients, sensitivity and specificity are 0.89% and 79.56% in group A5/6, and negative and positive predicted value (NPV, PPV) are 40% and 5%. The sensitivity, specificity, NPV, PPV in group A7 is 12.5%, 44.08%, 29.49% and 21.21%, respectively. The sensitivity, specificity, NPV, PPV in group A9 is 88.99%, 87.09%, 85.26%, 81.51%, respectively. Transformation zone type was correlated positively with positive cutting margin percentage (r = 0.8732, P < 0.05). Compared with type I, type II and III transformation zone is more likely to cause pathological upgrades. In conclusion, different types of transformation zone and high-risk HPV have clinical significance in causing positive cutting margin of surgery and disease extent.

  18. The CURB65 pneumonia severity score outperforms generic sepsis and early warning scores in predicting mortality in community‐acquired pneumonia

    PubMed Central

    Barlow, Gavin; Nathwani, Dilip; Davey, Peter

    2007-01-01

    Background The performance of CURB65 in predicting mortality in community‐acquired pneumonia (CAP) has been tested in two large observational studies. However, it has not been tested against generic sepsis and early warning scores, which are increasingly being advocated for identification of high‐risk patients in acute medical wards. Method A retrospective analysis was performed of data prospectively collected for a CAP quality improvement study. The ability to stratify mortality and performance characteristics (sensitivity, specificity, positive predictive value, negative predictive value and area under the receiver operating curve) were calculated for stratifications of CURB65, CRB65, the systemic inflammatory response syndrome (SIRS) criteria and the standardised early warning score (SEWS). Results 419 patients were included in the main analysis with a median age of 74 years (men = 47%). CURB65 and CRB65 stratified mortality in a more clinically useful way and had more favourable operating characteristics than SIRS or SEWS; for example, mortality in low‐risk patients was 2% when defined by CURB65, but 9% when defined by SEWS and 11–17% when defined by variations of the SIRS criteria. The sensitivity, specificity, positive predictive value and negative predictive value of CURB65 was 71%, 69%, 35% and 91%, respectively, compared with 62%, 73%, 35% and 89% for the best performing version of SIRS and 52%, 67%, 27% and 86% for SEWS. CURB65 had the greatest area under the receiver operating curve (0.78 v 0.73 for CRB65, 0.68 for SIRS and 0.64 for SEWS). Conclusions CURB65 should not be supplanted by SIRS or SEWS for initial prognostic assessment in CAP. Further research to identify better generic prognostic tools is required. PMID:16928720

  19. Mapping an operator's perception of a parameter space

    NASA Technical Reports Server (NTRS)

    Pew, R. W.; Jagacinski, R. J.

    1972-01-01

    Operators monitored the output of two versions of the crossover model having a common random input. Their task was to make discrete, real-time adjustments of the parameters k and tau of one of the models to make its output time history converge to that of the other, fixed model. A plot was obtained of the direction of parameter change as a function of position in the (tau, k) parameter space relative to the nominal value. The plot has a great deal of structure and serves as one form of representation of the operator's perception of the parameter space.

  20. Differentiation between microcystin contaminated and uncontaminated fish by determination of unconjugated MCs using an ELISA anti-Adda test based on receiver-operating characteristic curves threshold values: application to Tinca tinca from natural ponds.

    PubMed

    Moreno, Isabel María; Herrador, M Ángeles; Atencio, Loyda; Puerto, María; González, A Gustavo; Cameán, Ana María

    2011-02-01

    The aim of this study was to evaluate whether the enzyme-linked immunosorbent assay (ELISA) anti-Adda technique could be used to monitor free microcystins (MCs) in biological samples from fish naturally exposed to toxic cyanobacteria by using receiver operating characteristic (ROC) curve software to establish an optimal cut-off value for MCs. The cut-off value determined by ROC curve analysis in tench (Tinca tinca) exposed to MCs under laboratory conditions by ROC curve analysis was 5.90-μg MCs/kg tissue dry weight (d.w.) with a sensitivity of 93.3%. This value was applied in fish samples from natural ponds (Extremadura, Spain) in order to asses its potential MCs bioaccumulation by classifying samples as either true positive (TP), false positive (FP), true negative (TN), or false negative (FN). In this work, it has been demonstrated that toxic cyanobacteria, mainly Microcystis aeruginosa, Aphanizomenon issatchenkoi, and Anabaena spiroides, were present in two of these ponds, Barruecos de Abajo (BDown) and Barruecos de Arriba (BUp). The MCs levels were detected in waters from both ponds with an anti-MC-LR ELISA immunoassay and were of similar values (between 3.8-6.5-μg MC-LR equivalent/L in BDown pond and 4.8-6.0-μg MC-LR equivalent/L in BUp). The MCs cut-off values were applied in livers from fish collected from these two ponds using the ELISA anti-Adda technique. A total of 83% of samples from BDown pond and only 42% from BUp were TP with values of free MCs higher than 8.8-μg MCs/kg tissue (d.w.). Copyright © 2009 Wiley Periodicals, Inc.

  1. Experimental Robot Position Sensor Fault Tolerance Using Accelerometers and Joint Torque Sensors

    NASA Technical Reports Server (NTRS)

    Aldridge, Hal A.; Juang, Jer-Nan

    1997-01-01

    Robot systems in critical applications, such as those in space and nuclear environments, must be able to operate during component failure to complete important tasks. One failure mode that has received little attention is the failure of joint position sensors. Current fault tolerant designs require the addition of directly redundant position sensors which can affect joint design. The proposed method uses joint torque sensors found in most existing advanced robot designs along with easily locatable, lightweight accelerometers to provide a joint position sensor fault recovery mode. This mode uses the torque sensors along with a virtual passive control law for stability and accelerometers for joint position information. Two methods for conversion from Cartesian acceleration to joint position based on robot kinematics, not integration, are presented. The fault tolerant control method was tested on several joints of a laboratory robot. The controllers performed well with noisy, biased data and a model with uncertain parameters.

  2. Does pre-operative breast magnetic resonance imaging in addition to mammography and breast ultrasonography change the operative management of breast carcinoma?

    PubMed

    Lim, Hye In; Choi, Jae Hyuck; Yang, Jung-Hyun; Han, Boo-Kyung; Lee, Jeong Eon; Lee, Se-Kyung; Kim, Wan Wook; Kim, Sangmin; Kim, Jee Soo; Kim, Jung-Han; Choe, Jun-Ho; Cho, Eun Yoon; Kang, Seok Seon; Shin, Jung Hee; Ko, Eun Young; Kim, Sang Wook; Nam, Seok Jin

    2010-01-01

    Magnetic resonance imaging (MRI) has been used for the local staging of breast cancer, especially to determine the extent of multiple lesions and to identify occult malignancies. The aim of this study was to evaluate the effect of pre-operative MRI on the surgical treatment of breast cancer. Between January 2006 and May 2007, 535 newly diagnosed breast cancer patients who planned to undergo breast conserving surgery had clinical examinations, bilateral mammography, breast ultrasonography, and breast MRI. The radiologic findings and clinicopathologic data were reviewed retrospectively. Ninety-eight (18.3%) patients had additional lesions, shown as suspicious lesions on breast MRI, but not detected with conventional methods. Eighty-four (15.7%) of these patients had a change in surgical treatment plans based on the MRI results. Forty-seven (8.8%) of the 84 patients had additional malignancies;the other 37 patients (6.9%) had benign lesions. The positive predictive value for MRI-based surgery was 56.0% (47 of 84 patients). During the period of study, the use of pre-operative MRI was increased with time (OR 1.20; 95% CI 1.16-1.23; P < 0.001), but the mastectomy rate did not change significantly (OR 0.98; 95% CI 0.95-1.00; P = 0.059). Multiple factors were analyzed to identify the patients more likely to undergo appropriate and complete surgery based on the additional findings of the pre-operative MRI, but the results were not statistically significant. This research suggests that a pre-operative MRI can potentially lower the rate of incompletely excised malignancies by identifying additional occult cancer prior to surgery and does not lead to an increase in the mastectomy rate; however, because some benign lesions are indistinguishable from suspicious or malignant lesions, excessive surgical procedures are unnecessarily performed in a significant portion of patients. In the future, the criteria for the use of MRI in local staging of breast cancer should be established.

  3. Electrolytic cell stack with molten electrolyte migration control

    DOEpatents

    Kunz, H. Russell; Guthrie, Robin J.; Katz, Murray

    1988-08-02

    An electrolytic cell stack includes inactive electrolyte reservoirs at the upper and lower end portions thereof. The reservoirs are separated from the stack of the complete cells by impermeable, electrically conductive separators. Reservoirs at the negative end are initially low in electrolyte and the reservoirs at the positive end are high in electrolyte fill. During stack operation electrolyte migration from the positive to the negative end will be offset by the inactive reservoir capacity. In combination with the inactive reservoirs, a sealing member of high porosity and low electrolyte retention is employed to limit the electrolyte migration rate.

  4. Electrolytic cell stack with molten electrolyte migration control

    DOEpatents

    Kunz, H.R.; Guthrie, R.J.; Katz, M.

    1987-03-17

    An electrolytic cell stack includes inactive electrolyte reservoirs at the upper and lower end portions thereof. The reservoirs are separated from the stack of the complete cells by impermeable, electrically conductive separators. Reservoirs at the negative end are initially low in electrolyte and the reservoirs at the positive end are high in electrolyte fill. During stack operation electrolyte migration from the positive to the negative end will be offset by the inactive reservoir capacity. In combination with the inactive reservoirs, a sealing member of high porosity and low electrolyte retention is employed to limit the electrolyte migration rate. 5 figs.

  5. Surface Development and Test Facility (SDTF) New R&D Simulator for Airport Operations

    NASA Technical Reports Server (NTRS)

    Dorighi, Nancy S.

    1997-01-01

    A new simulator, the Surface Development and Test Facility (SDTF) is under construction at the NASA Ames Research Center in Mountain View, California. Jointly funded by the FAA (Federal Aviation Administration) and NASA, the SDTF will be a testbed for airport surface automation technologies of the future. The SDTF will be operational in the third quarter of 1998. The SDTF will combine a virtual tower with simulated ground operations to allow evaluation of new technologies for safety, effectiveness, reliability, and cost benefit. The full-scale level V tower will provide a seamless 360 degree high resolution out-the-window view, and a full complement of ATC (air traffic control) controller positions. The imaging system will be generated by two fully-configured Silicon Graphics Onyx Infinite Reality computers, and will support surface movement of up to 200 aircraft and ground vehicles. The controller positions, displays and consoles can be completely reconfigured to match the unique layout of any individual airport tower. Dedicated areas will accommodate pseudo-airport ramp controllers, pseudo-airport operators, and pseudo-pilots. Up to 33 total personnel positions will be able to participate in simultaneous operational scenarios. A realistic voice communication infrastructure will emulate the intercom and telephone communications of a real airport tower. Multi-channel audio and video recording and a sophisticated data acquisition system will support a wide variety of research and development areas, such as evaluation of automation tools for surface operations, human factors studies, integration of terminal area and airport technologies, and studies of potential airport physical and procedural modifications.

  6. Trainees do not negatively impact the institutional learning curve for robotic prostatectomy as characterized by operative time, estimated blood loss, and positive surgical margin rate.

    PubMed

    Schroeck, Florian R; de Sousa, Chiquita A Palha; Kalman, Ross A; Kalia, Maitri S; Pierre, Sean A; Haleblian, George E; Sun, Leon; Moul, Judd W; Albala, David M

    2008-04-01

    We evaluated the learning curves and perioperative outcomes of an experienced laparoscopic surgeon and his trainees to assess our structured teaching program. We retrieved 383 patients undergoing robot-assisted laparoscopic prostatectomy (RALP) from our database. Trainees completed a structured teaching program and were categorized as early (days 0 to 232), mid (days 566 to 797), and late (days 825 to 1218) according to the time period in which they were working with the mentor. We compared operative times, estimated blood loss (EBL), and positive surgical margin (PSM) rates between the trainees and the mentor (Mann-Whitney and Chi-square test). Association of EBL, body mass index (BMI), and prostate weight with operative time was evaluated in multivariate linear regression analysis. Median operative times of the early, mid, and late trainees (258, 220, and 200 minutes) significantly decreased and were similar to the corresponding senior surgeon's (254, 242, and 180 minutes). Operative times decreased with lower BMI, EBL, and prostate weight (P = 0.006, P <0.001, and P <0.001, respectively). Overall, EBL (150 mL vs. 150 mL, P = 0.215) and PSM rates (20% vs. 18.6%, P = 0.741) did not differ between the mentor and the trainees. A structured teaching program for RALP is effective and trainees are able to adopt the increased efficiency and skills of their mentor. Lower BMI, EBL, and prostate weight were associated with shorter operative times. Trainees performing the procedure did not negatively affect EBL and positive surgical margin rate.

  7. Comparative study between cytotoxicity and flowcytometry crossmatches before and after renal transplantation.

    PubMed

    Abdel Rahman, Afaf S; Fahim, Nehal M A; El Sayed, Abeer A; El Hady, Soha A R; Ahmad, Yasser S

    2005-01-01

    Renal transplantation, in most countries, is based on human leukocyte antigen (HLA) matching of the donor kidney with the recipient. Traditional human leukocyte antigen matching is based on defining human leukocyte antigen specificities by antibodies utilizing cytotoxicity crossmatch techniques. Newer techniques have emerged, which challenge the accuracy of serological typing and crossmatching. We compared the results of the standard complement-dependent cytotoxicity crossmatch (CDCXM) with the anti-human globulin augmented cytotoxicity (AHG-CDC), and Flowcytometry crossmatch (FCXM) for the detection of anti-HLA antibodies in 150 pre-transplant patients. The development of post-transplantation sensitization was screened utilizing these three techniques within two weeks post-operative and correlated with rejection episodes. Comparison between the results of CDCXM and AHG-CDC in 150 recipients, revealed no significant correlation (P>0.05). When comparing these results with that of FCXM in 50 recipients a significant correlation was shown (P<0.05). Relative to CDCXM, the sensitivity of AHG-CDC was 100%, specificity 97.4%, positive predictive value 92.3%, and negative predictive value 100%. On the other hand, the sensitivity of FCXM was 100%, specificity 76.3%, positive predictive value 57.1%, and negative predictive value 100%. According to the results of CDCXM, AHG-CDC, and FCXM, no difference was detected between pre- and posttransplant anti-HLA sensitization within two weeks after the operation. Patients with negative cytotoxicity crossmatch (CDCXM and AHG-CDC) and positive FCXM may have an increased risk of early graft loss and may represent a relative contraindication to transplantation. Given the important theoretical advantages of FCXM over the CDC XM, further testing of the clinical relevance is warranted.

  8. Comparison of Arterial Oxygenation Following Head-Down and Head-Up Laparoscopic Surgery.

    PubMed

    Imani, Farsad; Shirani Amniyeh, Fatemeh; Bastan Hagh, Ehsan; Khajavi, Mohammad Reza; Samimi, Saghar; Yousefshahi, Fardin

    2017-12-01

    Regarding the role of gas entry in abdomen and cardiorespiratory effects, the ability of anesthesiologists would be challenged in laparoscopic surgeries. Considering few studies in this area and the relevance of the subject, this study was performed to compare the arterial oxygen alterations before operation in comparison with after surgery between laparoscopic cholecystectomy and ovarian cystectomy. In this prospective cohort, 70 consecutive women aged from 20 to 60 years who were candidate for laparoscopic cholecystectomy (n = 35) and ovarian cystectomy (n = 35) with reverse (20 degrees) and direct (30 degrees) Trendelenburg positions, respectively, with ASA class I or II were enrolled. After intubation and before operation, for the first time, the arterial blood gas from radial artery in supine position was obtained for laboratory assessment. Then, the second blood sample was collected from radial artery in supine position and sent to the lab to be assessed with the same device after 30 minutes from surgery termination. The measured variables from arterial blood gas were arterial partial pressure of oxygen (PaO 2 ) and Oxygen saturation (SpO 2 ) alterations. Total PaO 2 was higher in the first measurement. The higher values of PaO 2 in cholecystectomy (upward) than in ovarian cystectomy (downward) were not significant in univariate (P = 0.060) and multivariate analysis (P = 0.654). Furthermore, higher values of SpO 2 in cholecystectomy (upward) than in ovarian cystectomy (downward) were not significant in univariate (P = 0.412) and multivariate analysis (P = 0.984). In general, based on the results of this study, the values of PaO 2 in cholecystectomy (upward) were not significantly higher than the values in cystectomy (downward) in laparoscopic surgeries when measured 30 minutes after surgery.

  9. Comparison of Arterial Oxygenation Following Head-Down and Head-Up Laparoscopic Surgery

    PubMed Central

    Imani, Farsad; Shirani Amniyeh, Fatemeh; Bastan Hagh, Ehsan; Khajavi, Mohammad Reza; Samimi, Saghar; Yousefshahi, Fardin

    2017-01-01

    Background Regarding the role of gas entry in abdomen and cardiorespiratory effects, the ability of anesthesiologists would be challenged in laparoscopic surgeries. Considering few studies in this area and the relevance of the subject, this study was performed to compare the arterial oxygen alterations before operation in comparison with after surgery between laparoscopic cholecystectomy and ovarian cystectomy. Methods In this prospective cohort, 70 consecutive women aged from 20 to 60 years who were candidate for laparoscopic cholecystectomy (n = 35) and ovarian cystectomy (n = 35) with reverse (20 degrees) and direct (30 degrees) Trendelenburg positions, respectively, with ASA class I or II were enrolled. After intubation and before operation, for the first time, the arterial blood gas from radial artery in supine position was obtained for laboratory assessment. Then, the second blood sample was collected from radial artery in supine position and sent to the lab to be assessed with the same device after 30 minutes from surgery termination. The measured variables from arterial blood gas were arterial partial pressure of oxygen (PaO2) and Oxygen saturation (SpO2) alterations. Results Total PaO2 was higher in the first measurement. The higher values of PaO2 in cholecystectomy (upward) than in ovarian cystectomy (downward) were not significant in univariate (P = 0.060) and multivariate analysis (P = 0.654). Furthermore, higher values of SpO2 in cholecystectomy (upward) than in ovarian cystectomy (downward) were not significant in univariate (P = 0.412) and multivariate analysis (P = 0.984). Conclusions In general, based on the results of this study, the values of PaO2 in cholecystectomy (upward) were not significantly higher than the values in cystectomy (downward) in laparoscopic surgeries when measured 30 minutes after surgery. PMID:29696125

  10. Unipolar Terminal-Attractor Based Neural Associative Memory with Adaptive Threshold

    NASA Technical Reports Server (NTRS)

    Liu, Hua-Kuang (Inventor); Barhen, Jacob (Inventor); Farhat, Nabil H. (Inventor); Wu, Chwan-Hwa (Inventor)

    1996-01-01

    A unipolar terminal-attractor based neural associative memory (TABAM) system with adaptive threshold for perfect convergence is presented. By adaptively setting the threshold values for the dynamic iteration for the unipolar binary neuron states with terminal-attractors for the purpose of reducing the spurious states in a Hopfield neural network for associative memory and using the inner-product approach, perfect convergence and correct retrieval is achieved. Simulation is completed with a small number of stored states (M) and a small number of neurons (N) but a large M/N ratio. An experiment with optical exclusive-OR logic operation using LCTV SLMs shows the feasibility of optoelectronic implementation of the models. A complete inner-product TABAM is implemented using a PC for calculation of adaptive threshold values to achieve a unipolar TABAM (UIT) in the case where there is no crosstalk, and a crosstalk model (CRIT) in the case where crosstalk corrupts the desired state.

  11. Unipolar terminal-attractor based neural associative memory with adaptive threshold

    NASA Technical Reports Server (NTRS)

    Liu, Hua-Kuang (Inventor); Barhen, Jacob (Inventor); Farhat, Nabil H. (Inventor); Wu, Chwan-Hwa (Inventor)

    1993-01-01

    A unipolar terminal-attractor based neural associative memory (TABAM) system with adaptive threshold for perfect convergence is presented. By adaptively setting the threshold values for the dynamic iteration for the unipolar binary neuron states with terminal-attractors for the purpose of reducing the spurious states in a Hopfield neural network for associative memory and using the inner product approach, perfect convergence and correct retrieval is achieved. Simulation is completed with a small number of stored states (M) and a small number of neurons (N) but a large M/N ratio. An experiment with optical exclusive-OR logic operation using LCTV SLMs shows the feasibility of optoelectronic implementation of the models. A complete inner-product TABAM is implemented using a PC for calculation of adaptive threshold values to achieve a unipolar TABAM (UIT) in the case where there is no crosstalk, and a crosstalk model (CRIT) in the case where crosstalk corrupts the desired state.

  12. Information recall using relative spike timing in a spiking neural network.

    PubMed

    Sterne, Philip

    2012-08-01

    We present a neural network that is capable of completing and correcting a spiking pattern given only a partial, noisy version. It operates in continuous time and represents information using the relative timing of individual spikes. The network is capable of correcting and recalling multiple patterns simultaneously. We analyze the network's performance in terms of information recall. We explore two measures of the capacity of the network: one that values the accurate recall of individual spike times and another that values only the presence or absence of complete patterns. Both measures of information are found to scale linearly in both the number of neurons and the period of the patterns, suggesting these are natural measures of network information. We show a smooth transition from encodings that provide precise spike times to flexible encodings that can encode many scenes. This makes it plausible that many diverse tasks could be learned with such an encoding.

  13. Spine surgeon's kinematics during discectomy, part II: operating table height and visualization methods, including microscope.

    PubMed

    Park, Jeong Yoon; Kim, Kyung Hyun; Kuh, Sung Uk; Chin, Dong Kyu; Kim, Keun Su; Cho, Yong Eun

    2014-05-01

    Surgeon spine angle during surgery was studied ergonomically and the kinematics of the surgeon's spine was related with musculoskeletal fatigue and pain. Spine angles varied depending on operation table height and visualization method, and in a previous paper we showed that the use of a loupe and a table height at the midpoint between the umbilicus and the sternum are optimal for reducing musculoskeletal loading. However, no studies have previously included a microscope as a possible visualization method. The objective of this study is to assess differences in surgeon spine angles depending on operating table height and visualization method, including microscope. We enrolled 18 experienced spine surgeons for this study, who each performed a discectomy using a spine surgery simulator. Three different methods were used to visualize the surgical field (naked eye, loupe, microscope) and three different operating table heights (anterior superior iliac spine, umbilicus, the midpoint between the umbilicus and the sternum) were studied. Whole spine angles were compared for three different views during the discectomy simulation: midline, ipsilateral, and contralateral. A 16-camera optoelectronic motion analysis system was used, and 16 markers were placed from the head to the pelvis. Lumbar lordosis, thoracic kyphosis, cervical lordosis, and occipital angle were compared between the different operating table heights and visualization methods as well as a natural standing position. Whole spine angles differed significantly depending on visualization method. All parameters were closer to natural standing values when discectomy was performed with a microscope, and there were no differences between the naked eye and the loupe. Whole spine angles were also found to differ from the natural standing position depending on operating table height, and became closer to natural standing position values as the operating table height increased, independent of the visualization method. When using a microscope, lumbar lordosis, thoracic kyphosis, and cervical lordosis showed no differences according to table heights above the umbilicus. This study suggests that the use of a microscope and a table height above the umbilicus are optimal for reducing surgeon musculoskeletal fatigue.

  14. [The "Würzburg T". A concept for optimization of early multiple trauma care in the emergency department].

    PubMed

    Kuhnigk, H; Steinhübel, B; Keil, T; Roewer, N

    2004-07-01

    Anaesthesia management, radiological diagnostic and the concept of damage control surgery should be combined in the resuscitation room. Defined clinical targets and their realisation are a CT-scan and complete damage control surgery in the shock room. Furthermore minimised patient transfer and positioning with continuous access to the head, upper parts of the body and anaesthesia machine should be realised during diagnostic procedures. Based on a carbon-slide fixed on a turntable and innovative alignment of diagnostic devices, a three phase treatment algorithm has been established. Phase A includes primary survey, anaesthetic management and ultrasound examination. Following a turn of the table conventional x-ray diagnostic is assessed in phase B. Tracks for the slide enable immediate transfer to a spiral CT-scan without additional patient positioning (phase C). Following complete CT-scan rearrangement of the table to phase A facilitates immediate damage control surgery. To accelerate device operation and treatment the integrated anaesthesia workstation is ceiling-mounted and manoeuvres close to the patient. This concept realizes complete diagnostic procedures and damage control surgery without time consuming patient transfer or rearrangement.

  15. Quality of diagnosis and monitoring of tuberculosis in Northern Ethiopia: medical records-based retrospective study.

    PubMed

    Mala, George; Spigt, Mark G; Gidding, Luc G; Blanco, Roman; Dinant, Geert-Jan

    2015-10-01

    To determine quality of diagnosis and monitoring of treatment response of patients with smear-negative pulmonary tuberculosis (TB) compared with smear-positive cases in Ethiopia. A retrospective analysis of medical records of newly diagnosed pulmonary TB cases that were registered for taking anti-TB medication and had completed treatment between 2010 and 2012. We evaluated the percentage of cases that were managed according to the International Standards of Tuberculosis Care (ISTC) and compared smear-negative with smear-positive cases. We analysed 1168 cases of which 742 (64%) were sputum smear-negative cases. Chest radiography examination at diagnosis and microbiological testing at the end of the intensive phase of treatment was performed in a smaller proportion than in smear-positive TB cases (70% vs. 79%, P value <0.001) and (70% vs. 95%, P value <0.001), respectively. Clinical actions recommended in the ISTC are of greatest importance in minimising pitfalls in care of smear-negative TB yet were performed less often in smear-negative than smear-positive TB cases. © The Author(s) 2015.

  16. Applied Meteorology Unit (AMU)

    NASA Technical Reports Server (NTRS)

    Bauman, William; Lambert, Winifred; Case, Jonathan; Short, David; Barrett, Joe

    2006-01-01

    Develop climatologies of gridded CG lightning densities and frequencies of occurrence for the Melbourne, FL National Weather Service (NWS MLB) county warning area. These grids are used to create a first-guess field for the lightning threat index map that is available on the NWS MLB NASA KSCIKT website. Forecasters previously created this map from scratch. Having the climatologies as a background field will increase consistency between forecasters and decrease their workload. Delivered all files containing the lightning climatologies, the data, and the code used to create the climatologies to NWS MLB. Completed and distributed a final memorandum describing how the climatologies were created. All the files were installed on the NWS MLB computer system, and then the code was compiled and tested to ensure that it worked properly on their operating system. The climatologies and their descriptions are posted on the NWS MLB website. Forecasting Low-Level Convergent Bands Under Southeast Flow Provide guidance to operational personnel that will help improve their forecasts of cloud bands under large-scale southeast flow. When these bands occur, they can lead to cloud, rain, and thunderstorm occurrences that adversely affect launch, landing, and ground operations at Kennedy Space Center/Cape Canaveral Air Force Station (KSC/CCAFS). Completed the first draft of the final report. The conclusions from this task indicated low-level wind speed and direction, low-level high pressure ridge position, east coast sea breeze front activity and upper-level jet streak position have the greatest influence on convergent band formation and movement during southeasterly flow.

  17. The Invisible Wound: Moral Injury and Its Impact on the Health of Operation Enduring Freedom/Operation Iraqi Freedom Veterans.

    PubMed

    Yan, Grace W

    2016-05-01

    Many veterans are now returning from Operation Enduring Freedom and Operation Iraqi Freedom (OEF/OIF) deployments with physical and mental health problems. However, there are few studies that examine the impact of moral injury on both physical and mental well-being. This study examines the impact of moral injury on self-reported general physical health, general mental health, post-traumatic stress disorder symptoms, and depression symptoms. Cross-sectional data were collected at as part of a pilot study at the New Jersey Veteran Affairs. 100 OEF/OIF veterans recruited at the New Jersey Veteran Affairs completed the paper questionnaire. We found that moral injury and combat experiences positively predicted post-traumatic stress disorder scores. Seeing the aftermath of battle and moral injury were negatively associated with mental well-being and positively associated with depression. Physical health status was negatively associated with depression. Spirituality and moral injury were negatively associated with physical health, whereas age was positively associated with physical health. Moral injury plays an important role in both physical and mental health outcomes for OEF/OIF veterans, but it is often not addressed in health care. These results underline the need for an approach to veterans' health care that includes discussion of existential and moral issues since they may impact health outcomes for many service members. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  18. Basic Values, Career Orientations, and Career Anchors: Empirical Investigation of Relationships

    PubMed Central

    Abessolo, Marc; Rossier, Jérôme; Hirschi, Andreas

    2017-01-01

    In today's dynamic and uncertain career context, values play an important role for career choice and lifelong career self-management. Values are desirable goals that are sought by individuals to satisfy their needs and are important for understanding career orientations in terms of protean and boundaryless career orientations and career anchors. However, how career orientations or career anchors fit into a well-established and supported model and into the structure of basic human values remains an important and under-investigated question. The aim of this study was to use Schwartz's model of structural values to empirically explore the relationships and structural correspondences among basic values, career orientations, and career anchors. A heterogeneous sample of 238 employees from French-speaking Switzerland (Mage = 35.60, SD = 13.03) completed the Portrait Values Questionnaire (PVQ5X), the Protean and Boundaryless Career Attitudes Scales (PCAS, BCAS), and the Career Orientation Inventory (COI) via an anonymous and confidential survey questionnaire. The results showed that it was possible to meaningfully position both career orientations and career anchors in Schwartz's values structure. The protean and boundaryless career orientations were positively related to Schwartz's basic values that emphasized openness to change and career anchors meaningfully followed the motivational continuum of these basic values. Overall, the overlap among the basic values, career orientations, and career anchors appeared relatively important, suggesting that these basic values, orientations, and anchors should be considered simultaneously to understand and address the factors and processes underlying individuals' career choices and paths. PMID:28955275

  19. Basic Values, Career Orientations, and Career Anchors: Empirical Investigation of Relationships.

    PubMed

    Abessolo, Marc; Rossier, Jérôme; Hirschi, Andreas

    2017-01-01

    In today's dynamic and uncertain career context, values play an important role for career choice and lifelong career self-management. Values are desirable goals that are sought by individuals to satisfy their needs and are important for understanding career orientations in terms of protean and boundaryless career orientations and career anchors. However, how career orientations or career anchors fit into a well-established and supported model and into the structure of basic human values remains an important and under-investigated question. The aim of this study was to use Schwartz's model of structural values to empirically explore the relationships and structural correspondences among basic values, career orientations, and career anchors. A heterogeneous sample of 238 employees from French-speaking Switzerland (Mage = 35.60, SD = 13.03) completed the Portrait Values Questionnaire (PVQ5X), the Protean and Boundaryless Career Attitudes Scales (PCAS, BCAS), and the Career Orientation Inventory (COI) via an anonymous and confidential survey questionnaire. The results showed that it was possible to meaningfully position both career orientations and career anchors in Schwartz's values structure. The protean and boundaryless career orientations were positively related to Schwartz's basic values that emphasized openness to change and career anchors meaningfully followed the motivational continuum of these basic values. Overall, the overlap among the basic values, career orientations, and career anchors appeared relatively important, suggesting that these basic values, orientations, and anchors should be considered simultaneously to understand and address the factors and processes underlying individuals' career choices and paths.

  20. The existence of semiregular solutions to elliptic spectral problems with discontinuous nonlinearities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pavlenko, V N; Potapov, D K

    2015-09-30

    This paper is concerned with the existence of semiregular solutions to the Dirichlet problem for an equation of elliptic type with discontinuous nonlinearity and when the differential operator is not assumed to be formally self-adjoint. Theorems on the existence of semiregular (positive and negative) solutions for the problem under consideration are given, and a principle of upper and lower solutions giving the existence of semiregular solutions is established. For positive values of the spectral parameter, elliptic spectral problems with discontinuous nonlinearities are shown to have nontrivial semiregular (positive and negative) solutions. Bibliography: 32 titles.

  1. Quantum Image Processing and Its Application to Edge Detection: Theory and Experiment

    NASA Astrophysics Data System (ADS)

    Yao, Xi-Wei; Wang, Hengyan; Liao, Zeyang; Chen, Ming-Cheng; Pan, Jian; Li, Jun; Zhang, Kechao; Lin, Xingcheng; Wang, Zhehui; Luo, Zhihuang; Zheng, Wenqiang; Li, Jianzhong; Zhao, Meisheng; Peng, Xinhua; Suter, Dieter

    2017-07-01

    Processing of digital images is continuously gaining in volume and relevance, with concomitant demands on data storage, transmission, and processing power. Encoding the image information in quantum-mechanical systems instead of classical ones and replacing classical with quantum information processing may alleviate some of these challenges. By encoding and processing the image information in quantum-mechanical systems, we here demonstrate the framework of quantum image processing, where a pure quantum state encodes the image information: we encode the pixel values in the probability amplitudes and the pixel positions in the computational basis states. Our quantum image representation reduces the required number of qubits compared to existing implementations, and we present image processing algorithms that provide exponential speed-up over their classical counterparts. For the commonly used task of detecting the edge of an image, we propose and implement a quantum algorithm that completes the task with only one single-qubit operation, independent of the size of the image. This demonstrates the potential of quantum image processing for highly efficient image and video processing in the big data era.

  2. Personal Care Participation Assessment and Resource Tool: Clinical utility for inpatient rehabilitation.

    PubMed

    Darzins, Susan W; Imms, Christine; Stefano, Marilyn Di; Radia-George, Camilla A

    2016-10-01

    Evidence supports validity of the Personal Care Participation Assessment and Resource Tool (PC-PART), but clinical utility remains unverified. This study aimed to investigate occupational therapists' perceptions about the PC-PART's clinical utility for inpatient rehabilitation. Using mixed methods, occupational therapists who had used the PC-PART as part of a research study in an inpatient rehabilitation setting completed a questionnaire ( n = 9) and participated in a focus group ( n = 6) to explore their perspectives about its clinical utility. Quantitative data were summarized and qualitative data analyzed using inductive thematic analysis. Quantitative data highlighted both positive and negative aspects of the PC-PART's clinical utility. Five themes emerged from the qualitative data: nature of information gathered; familiarity with the instrument; perceived time and effort; item phrasing, interpretation, and presentation; and external influences on clinical use. The PC-PART was perceived to support gathering of clinically useful information, helpful to intervention and discharge planning. Recommendations for improving some item phrasing, operational definitions, and instructions were identified. Although standardized assessments were valued, use in routine practice was challenging, requiring a knowledge translation strategy.

  3. Does exposure to simulated patient cases improve accuracy of clinicians' predictive value estimates of diagnostic test results? A within-subjects experiment at St Michael's Hospital, Toronto, Canada.

    PubMed

    Armstrong, Bonnie; Spaniol, Julia; Persaud, Nav

    2018-02-13

    Clinicians often overestimate the probability of a disease given a positive test result (positive predictive value; PPV) and the probability of no disease given a negative test result (negative predictive value; NPV). The purpose of this study was to investigate whether experiencing simulated patient cases (ie, an 'experience format') would promote more accurate PPV and NPV estimates compared with a numerical format. Participants were presented with information about three diagnostic tests for the same fictitious disease and were asked to estimate the PPV and NPV of each test. Tests varied with respect to sensitivity and specificity. Information about each test was presented once in the numerical format and once in the experience format. The study used a 2 (format: numerical vs experience) × 3 (diagnostic test: gold standard vs low sensitivity vs low specificity) within-subjects design. The study was completed online, via Qualtrics (Provo, Utah, USA). 50 physicians (12 clinicians and 38 residents) from the Department of Family and Community Medicine at St Michael's Hospital in Toronto, Canada, completed the study. All participants had completed at least 1 year of residency. Estimation accuracy was quantified by the mean absolute error (MAE; absolute difference between estimate and true predictive value). PPV estimation errors were larger in the numerical format (MAE=32.6%, 95% CI 26.8% to 38.4%) compared with the experience format (MAE=15.9%, 95% CI 11.8% to 20.0%, d =0.697, P<0.001). Likewise, NPV estimation errors were larger in the numerical format (MAE=24.4%, 95% CI 14.5% to 34.3%) than in the experience format (MAE=11.0%, 95% CI 6.5% to 15.5%, d =0.303, P=0.015). Exposure to simulated patient cases promotes accurate estimation of predictive values in clinicians. This finding carries implications for diagnostic training and practice. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Clinician Suspicion of an Alcohol Problem: An Observational Study From the AAFP National Research Network

    PubMed Central

    Vinson, Daniel C.; Turner, Barbara J.; MSED; Manning, Brian K.; Galliher, James M.

    2013-01-01

    PURPOSE In clinical practice, detection of alcohol problems often relies on clinician suspicion instead of using a screening instrument. We assessed the sensitivity, specificity, and predictive values of clinician suspicion compared with screening-detected alcohol problems in patients. METHODS We undertook a cross-sectional study of 94 primary care clinicians’ office visits. Brief questionnaires were completed separately after a visit by both clinicians and eligible patients. The patient’s anonymous exit questionnaire screened for hazardous drinking based on the Alcohol Use Disorders Identification Test-Consumption (AUDIT-C) and for harmful drinking (alcohol abuse or dependence) based on 2 questions from the Diagnostic and Statistical Manual of Mental Disorders. After the visit, clinicians responded to the question, “Does this patient have problems with alcohol?” with answer options including “yes, hazardous drinking” and “yes, alcohol abuse or dependence.” Analyses assessed the associations between patients’ responses to screening questions and clinician’s suspicions. RESULTS Of 2,518 patients with an office visit, 2,173 were eligible, and 1,699 (78%) completed the exit questionnaire. One hundred seventy-one (10.1%) patients had a positive screening test for hazardous drinking (an AUDIT-C score of 5 or greater) and 64 (3.8%) for harmful drinking. Clinicians suspected alcohol problems in 81 patients (hazardous drinking in 37, harmful drinking in 40, and both in 4). The sensitivity of clinician suspicion of either hazardous or harmful drinking was 27% and the specificity was 98%. Positive and negative predictive values were 62% and 92%, respectively. CONCLUSION Clinician suspicion of alcohol problems had poor sensitivity but high specificity for identifying patients who had a positive screening test for alcohol problems. These data support the routine use of a screening tool to supplement clinicians’ suspicions, which already provide reasonable positive predictive value. PMID:23319506

  5. Daily Stress, Coping, and Negative and Positive Affect in Depression: Complex Trigger and Maintenance Patterns.

    PubMed

    Dunkley, David M; Lewkowski, Maxim; Lee, Ihno A; Preacher, Kristopher J; Zuroff, David C; Berg, Jody-Lynn; Foley, J Elizabeth; Myhr, Gail; Westreich, Ruta

    2017-05-01

    Major depressive disorder is characterized by emotional dysfunction, but mood states in daily life are not well understood. This study examined complex explanatory models of daily stress and coping mechanisms that trigger and maintain daily negative affect and (lower) positive affect in depression. Sixty-three depressed patients completed perfectionism measures, and then completed daily questionnaires of stress appraisals, coping, and affect for 7 consecutive days. Multilevel structural equation modeling (MSEM) demonstrated that, across many stressors, when the typical individual with depression perceives more criticism than usual, he/she uses more avoidant coping and experiences higher event stress than usual, and this is connected to daily increases in negative affect as well as decreases in positive affect. In parallel, results showed that perceived control, less avoidant coping, and problem-focused coping commonly operate together when daily positive affect increases. MSEM also showed that avoidant coping tendencies and ongoing stress, in combination, explain why people with depression and higher self-critical perfectionism maintain daily negative affect and lower positive affect. These findings advance a richer and more detailed understanding of specific stress and coping patterns to target in order to more effectively accomplish the two predominant therapy goals of decreasing patients' distress and strengthening resilience. Copyright © 2016. Published by Elsevier Ltd.

  6. More screen operation than calling: the results of observing cyclists' behaviour while using mobile phones.

    PubMed

    de Waard, Dick; Westerhuis, Frank; Lewis-Evans, Ben

    2015-03-01

    Operating a mobile telephone while riding a bicycle is fairly common practice in the Netherlands, yet it is unknown if this use is stable or increasing. As such, whether the prevalence of mobile phone use while cycling has changed over the past five years was studied via on-road observation. In addition the impact of mobile phone use on lateral position, i.e. distance from the front wheel to the curb, was also examined to see if it compared to the results seen in previous experimental studies. Bicyclists were observed at six different locations and their behaviour was scored. It was found that compared to five years ago the use of mobile phones while cycling has changed, not in frequency, but in how cyclists were operating their phones. As found in 2008, three percent of the bicyclists were observed to be operating a phone, but a shift from calling (0.7% of cyclists observed) to operating (typing, texting, 2.3% of cyclists) was found. In 2008 nearly the complete opposite usage was observed: 2.2% of the cyclists were calling and 0.6% was texting. Another finding was that effects on lateral position were similar to those seen in experimental studies in that cyclists using a phone maintained a cycling position which was further away from the curb. It was also found that when at an intersection, cyclist's operating their phone made less head movements to the right than cyclists who were just cycling. This shift from calling to screen operation, when combined with the finding related to reduced head movements at intersections, is worrying and potentially dangerous. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Self-evaluation on Motion Adaptation for Service Robots

    NASA Astrophysics Data System (ADS)

    Funabora, Yuki; Yano, Yoshikazu; Doki, Shinji; Okuma, Shigeru

    We suggest self motion evaluation method to adapt to environmental changes for service robots. Several motions such as walking, dancing, demonstration and so on are described with time series patterns. These motions are optimized with the architecture of the robot and under certain surrounding environment. Under unknown operating environment, robots cannot accomplish their tasks. We propose autonomous motion generation techniques based on heuristic search with histories of internal sensor values. New motion patterns are explored under unknown operating environment based on self-evaluation. Robot has some prepared motions which realize the tasks under the designed environment. Internal sensor values observed under the designed environment with prepared motions show the interaction results with the environment. Self-evaluation is composed of difference of internal sensor values between designed environment and unknown operating environment. Proposed method modifies the motions to synchronize the interaction results on both environment. New motion patterns are generated to maximize self-evaluation function without external information, such as run length, global position of robot, human observation and so on. Experimental results show that the possibility to adapt autonomously patterned motions to environmental changes.

  8. Work climate, work values and professional commitment as predictors of job satisfaction in nurses.

    PubMed

    Caricati, Luca; Sala, Rachele La; Marletta, Giuseppe; Pelosi, Giulia; Ampollini, Monica; Fabbri, Anna; Ricchi, Alba; Scardino, Marcello; Artioli, Giovanna; Mancini, Tiziana

    2014-11-01

    To investigate the effect of some psychosocial variables on nurses' job satisfaction. Nurses' job satisfaction is one of the most important factors in determining individuals' intention to stay or leave a health-care organisation. Literature shows a predictive role of work climate, professional commitment and work values on job satisfaction, but their conjoint effect has rarely been considered. A cross-sectional questionnaire survey was adopted. Participants were hospital nurses and data were collected in 2011. Professional commitment and work climate positively predicted nurses' job satisfaction. The effect of intrinsic vs. extrinsic work value orientation on job satisfaction was completely mediated by professional commitment. Nurses' job satisfaction is influenced by both contextual and personal variables, in particular work climate and professional commitment. According to a more recent theoretical framework, work climate, work values and professional commitment interact with each other in determining nurses' job satisfaction. Nursing management must be careful to keep the context of work tuned to individuals' attitude and vice versa. Improving the work climate can have a positive effect on job satisfaction, but its effect may be enhanced by favouring strong professional commitment and by promoting intrinsic more than extrinsic work values. © 2013 John Wiley & Sons Ltd.

  9. Performance and Accuracy of Lightweight and Low-Cost GPS Data Loggers According to Antenna Positions, Fix Intervals, Habitats and Animal Movements

    PubMed Central

    Forin-Wiart, Marie-Amélie; Hubert, Pauline; Sirguey, Pascal; Poulle, Marie-Lazarine

    2015-01-01

    Recently developed low-cost Global Positioning System (GPS) data loggers are promising tools for wildlife research because of their affordability for low-budget projects and ability to simultaneously track a greater number of individuals compared with expensive built-in wildlife GPS. However, the reliability of these devices must be carefully examined because they were not developed to track wildlife. This study aimed to assess the performance and accuracy of commercially available GPS data loggers for the first time using the same methods applied to test built-in wildlife GPS. The effects of antenna position, fix interval and habitat on the fix-success rate (FSR) and location error (LE) of CatLog data loggers were investigated in stationary tests, whereas the effects of animal movements on these errors were investigated in motion tests. The units operated well and presented consistent performance and accuracy over time in stationary tests, and the FSR was good for all antenna positions and fix intervals. However, the LE was affected by the GPS antenna and fix interval. Furthermore, completely or partially obstructed habitats reduced the FSR by up to 80% in households and increased the LE. Movement across habitats had no effect on the FSR, whereas forest habitat influenced the LE. Finally, the mean FSR (0.90 ± 0.26) and LE (15.4 ± 10.1 m) values from low-cost GPS data loggers were comparable to those of built-in wildlife GPS collars (71.6% of fixes with LE < 10 m for motion tests), thus confirming their suitability for use in wildlife studies. PMID:26086958

  10. Astronomical Methods in Aerial Navigation

    NASA Technical Reports Server (NTRS)

    Beij, K Hilding

    1925-01-01

    The astronomical method of determining position is universally used in marine navigation and may also be of service in aerial navigation. The practical application of the method, however, must be modified and adapted to conform to the requirements of aviation. Much of this work of adaptation has already been accomplished, but being scattered through various technical journals in a number of languages, is not readily available. This report is for the purpose of collecting under one cover such previous work as appears to be of value to the aerial navigator, comparing instruments and methods, indicating the best practice, and suggesting future developments. The various methods of determining position and their application and value are outlined, and a brief resume of the theory of the astronomical method is given. Observation instruments are described in detail. A complete discussion of the reduction of observations follows, including a rapid method of finding position from the altitudes of two stars. Maps and map cases are briefly considered. A bibliography of the subject is appended.

  11. The Value of Humans in the Operational River Forecasting Enterprise

    NASA Astrophysics Data System (ADS)

    Pagano, T. C.

    2012-04-01

    The extent of human control over operational river forecasts, such as by adjusting model inputs and outputs, varies from nearly completely automated systems to those where forecasts are generated after discussion among a group of experts. Historical and realtime data availability, the complexity of hydrologic processes, forecast user needs, and forecasting institution support/resource availability (e.g. computing power, money for model maintenance) influence the character and effectiveness of operational forecasting systems. Automated data quality algorithms, if used at all, are typically very basic (e.g. checks for impossible values); substantial human effort is devoted to cleaning up forcing data using subjective methods. Similarly, although it is an active research topic, nearly all operational forecasting systems struggle to make quantitative use of Numerical Weather Prediction model-based precipitation forecasts, instead relying on the assessment of meteorologists. Conversely, while there is a strong tradition in meteorology of making raw model outputs available to forecast users via the Internet, this is rarely done in hydrology; Operational river forecasters express concerns about exposing users to raw guidance, due to the potential for misinterpretation and misuse. However, this limits the ability of users to build their confidence in operational products through their own value-added analyses. Forecasting agencies also struggle with provenance (i.e. documenting the production process and archiving the pieces that went into creating a forecast) although this is necessary for quantifying the benefits of human involvement in forecasting and diagnosing weak links in the forecasting chain. In hydrology, the space between model outputs and final operational products is nearly unstudied by the academic community, although some studies exist in other fields such as meteorology.

  12. High-resolution room temperature and jet-cooled spectroscopic investigation of 15NH3 in the ν1+ν3 band region (1.51 μm)

    NASA Astrophysics Data System (ADS)

    Földes, T.; Vanfleteren, T.; Rizopoulos, A.; Herman, M.; Vander Auwera, J.; Softley, T. P.; Di Lonardo, G.; Fusina, L.

    2016-08-01

    Spectra of 99% isotopically pure 15NH3 were recorded using cavity ring-down (CRD, 6567-6639 cm-1) and Fourier transform (FT, 6350-6985 cm-1) spectroscopy under jet cooled and room temperature conditions, respectively. Measured line positions on both data sets improve on literature values, in particular by one order of magnitude for the ν1+ν3 band. A room temperature list of line positions, with approximate line intensities, is provided, much more complete and precise than presently available. Line broadening effects in the CRD spectrum allowed lines with J‧‧‧- values between 0 and 3 to be identified. Ground state combination differences were used to refine the assignments, further assisted by intensity ratios between the two data sets. Reliable values for J, K and inversion symmetry of the ground state vibrational levels, as well as further information on a/s doublets could be obtained, updating and extending literature assignments.

  13. Study on relationship of performance shaping factor in human error probability with prevalent stress of PUSPATI TRIGA reactor operators

    NASA Astrophysics Data System (ADS)

    Rahim, Ahmad Nabil Bin Ab; Mohamed, Faizal; Farid, Mohd Fairus Abdul; Fazli Zakaria, Mohd; Sangau Ligam, Alfred; Ramli, Nurhayati Binti

    2018-01-01

    Human factor can be affected by prevalence stress measured using Depression, Anxiety and Stress Scale (DASS). From the respondents feedback can be summarized that the main factor causes the highest prevalence stress is due to the working conditions that require operators to handle critical situation and make a prompt critical decisions. The relationship between the prevalence stress and performance shaping factors found that PSFFitness and PSFWork Process showed positive Pearson’s Correlation with the score of .763 and .826 while the level of significance, p = .028 and p = .012. These positive correlations with good significant values between prevalence stress and human performance shaping factor (PSF) related to fitness, work processes and procedures. The higher the stress level of the respondents, the higher the score of selected for the PSFs. This is due to the higher levels of stress lead to deteriorating physical health and cognitive also worsened. In addition, the lack of understanding in the work procedures can also be a factor that causes a growing stress. The higher these values will lead to the higher the probabilities of human error occur. Thus, monitoring the level of stress among operators RTP is important to ensure the safety of RTP.

  14. The position of a standard optical computer mouse affects cardiorespiratory responses during the operation of a computer under time constraints.

    PubMed

    Sako, Shunji; Sugiura, Hiromichi; Tanoue, Hironori; Kojima, Makoto; Kono, Mitsunobu; Inaba, Ryoichi

    2014-08-01

    This study investigated the association between task-induced stress and fatigue by examining the cardiovascular responses of subjects using different mouse positions while operating a computer under time constraints. The study was participated by 16 young, healthy men and examined the use of optical mouse devices affixed to laptop computers. Two mouse positions were investigated: (1) the distal position (DP), in which the subjects place their forearms on the desk accompanied by the abduction and flexion of their shoulder joints, and (2) the proximal position (PP), in which the subjects place only their wrists on the desk without using an armrest. The subjects continued each task for 16 min. We assessed differences in several characteristics according to mouse position, including expired gas values, autonomic nerve activities (based on cardiorespiratory responses), operating efficiencies (based on word counts), and fatigue levels (based on the visual analog scale - VAS). Oxygen consumption (VO(2)), the ratio of inspiration time to respiration time (T(i)/T(total)), respiratory rate (RR), minute ventilation (VE), and the ratio of expiration to inspiration (Te/T(i)) were significantly lower when the participants were performing the task in the DP than those obtained in the PP. Tidal volume (VT), carbon dioxide output rates (VCO(2)/VE), and oxygen extraction fractions (VO(2)/VE) were significantly higher for the DP than they were for the PP. No significant difference in VAS was observed between the positions; however, as the task progressed, autonomic nerve activities were lower and operating efficiencies were significantly higher for the DP than they were for the PP. Our results suggest that the DP has fewer effects on cardiorespiratory functions, causes lower levels of sympathetic nerve activity and mental stress, and produces a higher total workload than the PP. This suggests that the DP is preferable to the PP when operating a computer.

  15. Toward brain-computer interface based wheelchair control utilizing tactually-evoked event-related potentials

    PubMed Central

    2014-01-01

    Background People with severe disabilities, e.g. due to neurodegenerative disease, depend on technology that allows for accurate wheelchair control. For those who cannot operate a wheelchair with a joystick, brain-computer interfaces (BCI) may offer a valuable option. Technology depending on visual or auditory input may not be feasible as these modalities are dedicated to processing of environmental stimuli (e.g. recognition of obstacles, ambient noise). Herein we thus validated the feasibility of a BCI based on tactually-evoked event-related potentials (ERP) for wheelchair control. Furthermore, we investigated use of a dynamic stopping method to improve speed of the tactile BCI system. Methods Positions of four tactile stimulators represented navigation directions (left thigh: move left; right thigh: move right; abdomen: move forward; lower neck: move backward) and N = 15 participants delivered navigation commands by focusing their attention on the desired tactile stimulus in an oddball-paradigm. Results Participants navigated a virtual wheelchair through a building and eleven participants successfully completed the task of reaching 4 checkpoints in the building. The virtual wheelchair was equipped with simulated shared-control sensors (collision avoidance), yet these sensors were rarely needed. Conclusion We conclude that most participants achieved tactile ERP-BCI control sufficient to reliably operate a wheelchair and dynamic stopping was of high value for tactile ERP classification. Finally, this paper discusses feasibility of tactile ERPs for BCI based wheelchair control. PMID:24428900

  16. [Evaluation of performance of five bioinformatics software for the prediction of missense mutations].

    PubMed

    Chen, Qianting; Dai, Congling; Zhang, Qianjun; Du, Juan; Li, Wen

    2016-10-01

    To study the prediction performance evaluation with five kinds of bioinformatics software (SIFT, PolyPhen2, MutationTaster, Provean, MutationAssessor). From own database for genetic mutations collected over the past five years, Chinese literature database, Human Gene Mutation Database, and dbSNP, 121 missense mutations confirmed by functional studies, and 121 missense mutations suspected to be pathogenic by pedigree analysis were used as positive gold standard, while 242 missense mutations with minor allele frequency (MAF)>5% in dominant hereditary diseases were used as negative gold standard. The selected mutations were predicted with the five software. Based on the results, the performance of the five software was evaluated for their sensitivity, specificity, positive predict value, false positive rate, negative predict value, false negative rate, false discovery rate, accuracy, and receiver operating characteristic curve (ROC). In terms of sensitivity, negative predictive value and false negative rate, the rank was MutationTaster, PolyPhen2, Provean, SIFT, and MutationAssessor. For specificity and false positive rate, the rank was MutationTaster, Provean, MutationAssessor, SIFT, and PolyPhen2. For positive predict value and false discovery rate, the rank was MutationTaster, Provean, MutationAssessor, PolyPhen2, and SIFT. For area under the ROC curve (AUC) and accuracy, the rank was MutationTaster, Provean, PolyPhen2, MutationAssessor, and SIFT. The prediction performance of software may be different when using different parameters. Among the five software, MutationTaster has the best prediction performance.

  17. Usefulness of Two Aspergillus PCR Assays and Aspergillus Galactomannan and β-d-Glucan Testing of Bronchoalveolar Lavage Fluid for Diagnosis of Chronic Pulmonary Aspergillosis

    PubMed Central

    Urabe, Naohisa; Sano, Go; Suzuki, Junko; Hebisawa, Akira; Nakamura, Yasuhiko; Koyama, Kazuya; Ishii, Yoshikazu; Tateda, Kazuhiro; Homma, Sakae

    2017-01-01

    ABSTRACT We evaluated the usefulness of an Aspergillus galactomannan (GM) test, a β-d-glucan (βDG) test, and two different Aspergillus PCR assays of bronchoalveolar lavage fluid (BALF) samples for the diagnosis of chronic pulmonary aspergillosis (CPA). BALF samples from 30 patients with and 120 patients without CPA were collected. We calculated the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each test individually and in combination with other tests. The optical density index values, as determined by receiver operating characteristic analysis, for the diagnosis of CPA were 0.5 and 100 for GM and βDG testing of BALF, respectively. The sensitivity and specificity of the GM test, βDG test, and PCR assays 1 and 2 were 77.8% and 90.0%, 77.8% and 72.5%, 86.7% and 84.2%, and 66.7% and 94.2%, respectively. A comparison of the PCR assays showed that PCR assay 1 had a better sensitivity, a better negative predictive value, and a better negative likelihood ratio and PCR assay 2 had a better specificity, a better positive predictive value, and a better positive likelihood ratio. The combination of the GM and βDG tests had the highest diagnostic odds ratio. The combination of the GM and βDG tests on BALF was more useful than any single test for diagnosing CPA. PMID:28330887

  18. Severe community-acquired pneumonia. Assessment of severity criteria.

    PubMed

    Ewig, S; Ruiz, M; Mensa, J; Marcos, M A; Martinez, J A; Arancibia, F; Niederman, M S; Torres, A

    1998-10-01

    The purpose of the study was to validate the criteria used in the guidelines of the American Thoracic Society (ATS) for severe community-acquired pneumonia (CAP). Severe pneumonia was defined as admission to the intensive care unit (ICU). Overall 331 nonsevere (84%) and 64 severe cases (16%) of CAP were prospectively studied. Mortality was 19 of 395 (5%) and 19 of 64 (30%), respectively. Single severity criteria as well as the ATS definition of severe pneumonia were assessed calculating the operative indices. A modified prediction rule including minor (baseline) and major (baseline or evolutionary) criteria was derived. Single minor criteria at admission had a low sensitivity and positive predictive value. Defining severe pneumonia according to the ATS guidelines had a high sensitivity (98%). However, specificity and positive predictive value were low (32% and 24%, respectively). A modified prediction rule (presence of two or three minor criteria [systolic blood pressure < 90 mm Hg, multilobar involvement, PaO2/FIO2 < 250] or one of two major criteria [requirement of mechanical ventilation, presence of septic shock]) had a sensitivity of 78%, a specificity of 94%, a positive predictive value of 75%, and a negative predictive value of 95%. The ATS definition of severe pneumonia was highly sensitive but insufficiently specific and had a low positive predictive value. Our suggested modified rule had a more balanced performance and, if validated in an independent population, may represent a more accurate definition of severe CAP.

  19. Traditional Chinese medicine and the positive correlation with homeostatic evolution of human being: based on medical perspective.

    PubMed

    Wang, Jie-Hua

    2012-08-01

    Adaptation is an eternal theme of biological evolution. The paper aims at exploring the conception of positive correlation between traditional Chinese medicine (TCM) and human homeostatic evolution based on medical perspective. Discussions mainly involve TCM conforming to natural laws and natural evolution of life, spontaneous harmonization of yin and yang and operating system of human self-healing, modern human immunology and human endogenous immune function in TCM, self-homeostasis of human micro-ecological state and balance mechanism on regulating base in TCM, as well as adaptation-eternal theme of biological evolution and safeguarding adaptability-value of TCM. In perspective of medicine, theory and practice of TCM are in positive correlation with human homeostatic evolution, and what TCM tries to maintain is human intrinsic adaptive capability to disease and nature. Therefore, it is the core value of TCM, which is to be further studied, explored, realized and known to the world.

  20. [Predictive value and sensibility of hospital discharge system (PMSI) compared to cancer registries for thyroïd cancer (1999-2000)].

    PubMed

    Carré, N; Uhry, Z; Velten, M; Trétarre, B; Schvartz, C; Molinié, F; Maarouf, N; Langlois, C; Grosclaude, P; Colonna, M

    2006-09-01

    Cancer registries have a complete recording of new cancer cases occurring among residents of a specific geographic area. In France, they cover only 13% of the population. For thyroid cancer, where incidence rate is highly variable according to the district conversely to mortality, national incidence estimates are not accurate. A nationwide database, such as hospital discharge system, could improve this estimate but its positive predictive value and sensibility should be evaluated. The positive predictive value and the sensitivity for thyroid cancer case ascertainment (ICD-10) of the national hospital discharge system in 1999 and 2000 were estimated using the cancer registries database of 10 French districts as gold standard. The linkage of the two databases required transmission of nominative information from the health facilities of the study. From the registries database, a logistic regression analysis was carried out to identify factors related to being missed by the hospital discharge system. Among the 973 standardized discharge charts selected from the hospital discharge system, 866 were considered as true positive cases, and 107 as false positive. Forty five of the latter group were prevalent cases. The predictive positive value was 89% (95% confidence interval (CI): 87-91%) and did not differ according to the district (p=0,80). According to the cancer registries, 322 thyroid cancer cases diagnosed in 1999 or 2000 were missed by the hospital discharge system. Thus, the sensitivity of this latter system was 73% (70-76%) and varied significantly from 62% to 85% across districts (p<0.001) and according to the type of health facility (p<0.01). Predictive positive value of the French hospital discharge system for ascertainment of thyroid cancer cases is high and stable across districts. Sensitivity is lower and varies significantly according to the type of health facility and across districts, which limits the interest of this database for a national estimate of thyroid cancer incidence rate.

  1. Twenty-four hour intraocular pressure monitoring with the SENSIMED Triggerfish contact lens: effect of body posture during sleep.

    PubMed

    Beltran-Agulló, Laura; Buys, Yvonne M; Jahan, Farzana; Shapiro, Colin M; Flanagan, John G; Cheng, Jason; Trope, Graham E

    2017-10-01

    To determine the difference in relative intraocular pressure (IOP) measured by the SENSIMED Triggerfish (TF) contact lens in flat compared with 30° head-up sleeping positions in patients with progressive primary open-angle glaucoma or normotensive glaucoma, based on recent or recurrent disc haemorrhage. Prospective, randomised, cross-over, open-label comparative study. IOP was monitored for 24 hours using TF on two separate sessions. Patients were randomly assigned to sleep flat one night and 30° head-up the other. Outputs in arbitrary units were obtained. Sleep and wake periods were defined as 22:00-6:00 and 8:00-22:00, respectively. Mean TF values during sleep and wake periods and wake-sleep and sleep-wake slopes were calculated for each session. TF output signals were compared between positions. Twelve subjects completed the study. Significant mean positive slopes were noted during the sleep period for both positions (p<0.01). No significant differences in the TF mean values were observed between positions (p=0.51). Six (54%) subjects had mean TF values significantly higher during the flat supine session, while four (36%) subjects had higher values during the head-up session. A significant increase in Goldmann IOP (p=0.001) and TF (p=0.02) measurements were observed after 24 hours of TF wear ('drift phenomenon'). Sleep position affects IOP as measured by TF in some patients with progressive glaucoma. The upward drift in TF output detected in >50% of the subjects requires further investigation to establish whether the increased output values over time are an artefact induced by the TF or a real change in IOP. NCT01351779. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. Key results from the first plasma operation phase and outlook for future performance in Wendelstein 7-X

    PubMed Central

    Dinklage, Andreas; Turkin, Yuriy; Bozhenkov, Sergey; Geiger, Joachim; Fuchert, Golo; Bosch, Hans-Stephan; Rahbarnia, Kian; Thomsen, Henning; Neuner, Ulrich; Klinger, Thomas; Langenberg, Andreas; Trimiño Mora, Humberto; Kornejew, Petra; Hirsch, Matthias; Pablant, Novimir

    2017-01-01

    The first physics operation phase on the stellarator experiment Wendelstein 7-X was successfully completed in March 2016 after about 10 weeks of operation. Experiments in this phase were conducted with five graphite limiters as the primary plasma-facing components. Overall, the results were beyond the expectations published shortly before the start of operation [Sunn Pedersen et al., Nucl. Fusion 55, 126001 (2015)] both with respect to parameters reached and with respect to physics themes addressed. We report here on some of the most important plasma experiments that were conducted. The importance of electric fields on global confinement will be discussed, and the obtained results will be compared and contrasted with results from other devices, quantified in terms of the fusion triple product. Expected values for the triple product in future operation phases will also be described and put into a broader fusion perspective. PMID:29104420

  3. Development of Live-working Robot for Power Transmission Lines

    NASA Astrophysics Data System (ADS)

    Yan, Yu; Liu, Xiaqing; Ren, Chengxian; Li, Jinliang; Li, Hui

    2017-07-01

    Dream-I, the first reconfigurable live-working robot for power transmission lines successfully developed in China, has the functions of autonomous walking on lines and accurately positioning. This paper firstly described operation task and object of the robot; then designed a general platform, an insulator replacement end and a drainage plate bolt fastening end of the robot, presented a control system of the robot, and performed simulation analysis on operation plan of the robot; and finally completed electrical field withstand voltage tests in a high voltage hall as well as online test and trial on actual lines. Experimental results show that by replacing ends of manipulators, the robot can fulfill operation tasks of live replacement of suspension insulators and live drainage plate bolt fastening.

  4. Welding apparatus and methods for using ultrasonic sensing

    DOEpatents

    McJunkin, Timothy R.; Johnson, John A.; Larsen, Eric D.; Smartt, Herschel B.

    2006-08-22

    A welding apparatus using ultrasonic sensing is described and which includes a movable welder having a selectively adjustable welding head for forming a partially completed weld in a weld seam defined between adjoining metal substrates; an ultrasonic assembly borne by the moveable welder and which is operable to generate an ultrasonic signal which is directed toward the partially completed weld, and is further reflected from same; and a controller electrically coupled with the ultrasonic assembly and controllably coupled with the welding head, and wherein the controller receives information regarding the ultrasonic signal and in response to the information optimally positions the welding head relative to the weld seam.

  5. ASD-1000: High-resolution, high-temperature acetylene spectroscopic databank

    NASA Astrophysics Data System (ADS)

    Lyulin, O. M.; Perevalov, V. I.

    2017-11-01

    We present a high-resolution, high-temperature version of the Acetylene Spectroscopic Databank called ASD-1000. The databank contains the line parameters (position, intensity, Einstein coefficient for spontaneous emission, term value of the lower states, self- and air-broadening coefficients, temperature dependence exponents of the self- and air-broadening coefficients) of the principal isotopologue of C2H2. The reference temperature for line intensity is 296 K and the intensity cutoff is 10-27 cm-1/(molecule cm-2) at 1000 K. The databank has 33,890,981 entries and covers the 3-10,000 cm-1 spectral range. The databank is based on the global modeling of the line positions and intensities performed within the framework of the method of effective operators. The parameters of the effective Hamiltonian and the effective dipole moment operator have been fitted to the observed values of the line positions and intensities collected from the literature. The broadening coefficients as well as their temperature dependence exponents were calculated using the empirical equations. The databank is useful for studying high-temperature radiative properties of C2H2. ASD-1000 is freely accessible via the Internet site of V.E. Zuev Institute of Atmospheric Optics SB RAS ftp://ftp.iao.ru/pub/ASD1000/.

  6. Prospective in-patient cohort study of moves between levels of therapeutic security: the DUNDRUM-1 triage security, DUNDRUM-3 programme completion and DUNDRUM-4 recovery scales and the HCR-20.

    PubMed

    Davoren, Mary; O'Dwyer, Sarah; Abidin, Zareena; Naughton, Leena; Gibbons, Olivia; Doyle, Elaine; McDonnell, Kim; Monks, Stephen; Kennedy, Harry G

    2012-07-13

    We examined whether new structured professional judgment instruments for assessing need for therapeutic security, treatment completion and recovery in forensic settings were related to moves from higher to lower levels of therapeutic security and added anything to assessment of risk. This was a prospective naturalistic twelve month observational study of a cohort of patients in a forensic hospital placed according to their need for therapeutic security along a pathway of moves from high to progressively less secure units in preparation for discharge. Patients were assessed using the DUNDRUM-1 triage security scale, the DUNDRUM-3 programme completion scale and the DUNDRUM-4 recovery scale and assessments of risk of violence, self harm and suicide, symptom severity and global function. Patients were subsequently observed for positive moves to less secure units and negative moves to more secure units. There were 86 male patients at baseline with mean follow-up 0.9 years, 11 positive and 9 negative moves. For positive moves, logistic regression indicated that along with location at baseline, the DUNDRUM-1, HCR-20 dynamic and PANSS general symptom scores were associated with subsequent positive moves. The receiver operating characteristic was significant for the DUNDRUM-1 while ANOVA co-varying for both location at baseline and HCR-20 dynamic score was significant for DUNDRUM-1. For negative moves, logistic regression showed DUNDRUM-1 and HCR-20 dynamic scores were associated with subsequent negative moves, along with DUNDRUM-3 and PANSS negative symptoms in some models. The receiver operating characteristic was significant for the DUNDRUM-4 recovery and HCR-20 dynamic scores with DUNDRUM-1, DUNDRUM-3, PANSS general and GAF marginal. ANOVA co-varying for both location at baseline and HCR-20 dynamic scores showed only DUNDRUM-1 and PANSS negative symptoms associated with subsequent negative moves. Clinicians appear to decide moves based on combinations of current and imminent (dynamic) risk measured by HCR-20 dynamic score and historical seriousness of risk as measured by need for therapeutic security (DUNDRUM-1) in keeping with Scott's formulation of risk and seriousness. The DUNDRUM-3 programme completion and DUNDRUM-4 recovery scales have utility as dynamic measures that can off-set perceived 'dangerousness'.

  7. Prospective in-patient cohort study of moves between levels of therapeutic security: the DUNDRUM-1 triage security, DUNDRUM-3 programme completion and DUNDRUM-4 recovery scales and the HCR-20

    PubMed Central

    2012-01-01

    Background We examined whether new structured professional judgment instruments for assessing need for therapeutic security, treatment completion and recovery in forensic settings were related to moves from higher to lower levels of therapeutic security and added anything to assessment of risk. Methods This was a prospective naturalistic twelve month observational study of a cohort of patients in a forensic hospital placed according to their need for therapeutic security along a pathway of moves from high to progressively less secure units in preparation for discharge. Patients were assessed using the DUNDRUM-1 triage security scale, the DUNDRUM-3 programme completion scale and the DUNDRUM-4 recovery scale and assessments of risk of violence, self harm and suicide, symptom severity and global function. Patients were subsequently observed for positive moves to less secure units and negative moves to more secure units. Results There were 86 male patients at baseline with mean follow-up 0.9 years, 11 positive and 9 negative moves. For positive moves, logistic regression indicated that along with location at baseline, the DUNDRUM-1, HCR-20 dynamic and PANSS general symptom scores were associated with subsequent positive moves. The receiver operating characteristic was significant for the DUNDRUM-1 while ANOVA co-varying for both location at baseline and HCR-20 dynamic score was significant for DUNDRUM-1. For negative moves, logistic regression showed DUNDRUM-1 and HCR-20 dynamic scores were associated with subsequent negative moves, along with DUNDRUM-3 and PANSS negative symptoms in some models. The receiver operating characteristic was significant for the DUNDRUM-4 recovery and HCR-20 dynamic scores with DUNDRUM-1, DUNDRUM-3, PANSS general and GAF marginal. ANOVA co-varying for both location at baseline and HCR-20 dynamic scores showed only DUNDRUM-1 and PANSS negative symptoms associated with subsequent negative moves. Conclusions Clinicians appear to decide moves based on combinations of current and imminent (dynamic) risk measured by HCR-20 dynamic score and historical seriousness of risk as measured by need for therapeutic security (DUNDRUM-1) in keeping with Scott's formulation of risk and seriousness. The DUNDRUM-3 programme completion and DUNDRUM-4 recovery scales have utility as dynamic measures that can off-set perceived 'dangerousness'. PMID:22794187

  8. Diagnostic value of contrast-enhanced ultrasound in thyroid nodules with calcification.

    PubMed

    Jiang, Jue; Shang, Xu; Wang, Hua; Xu, Yong-Bo; Gao, Ya; Zhou, Qi

    2015-03-01

    The aim of this study was to investigate the diagnostic values of conventional ultrasound and contrast-enhanced ultrasound (CEUS) in benign and malignant thyroid nodules with calcification. Conventional ultrasound and CEUS were performed in 122 patients with thyroid nodules with calcification. The thyroid nodules were characterized as benign or malignant by pathological diagnosis. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate of the two imaging methods were determined. The area under the receiver operating characteristics curve (AUC) was used to assess the diagnostic values of the two imaging methods. In 122 cases of thyroid nodules with calcification, 73 benign nodules and 49 malignant nodules were verified by pathological diagnosis. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate of conventional ultrasound were 50%, 77%, 59%, 69%, and 66%, respectively, and those of CEUS were 90%, 92%, 88%, 93%, and 91%, respectively. There were significant differences between the two imaging methods. AUCs of conventional ultrasound and CEUS were 0.628 ± 0.052 and 0.908 ± 0.031, suggesting low and high diagnostic values, respectively. CEUS has high diagnostic values, being significantly greater than those of conventional ultrasound, in differential diagnosis of benign and malignant thyroid nodules with calcification. Copyright © 2014. Published by Elsevier Taiwan.

  9. Value of gastrografin in adhesive small bowel obstruction after unsuccessful conservative treatment: a prospective evaluation.

    PubMed

    Choi, Hok-Kwok; Law, Wai-Lun; Ho, Judy-Wai-Chu; Chu, Kin-Wah

    2005-06-28

    Gastrografin is a hyperosmolar water-soluble contrast medium. Besides its predictive value for the need for operative treatment, a potential therapeutic role of this agent in adhesive small bowel obstruction has been suggested. This study aimed at evaluating the effectiveness of gastrografin in adhesive small bowel obstruction when conservative treatment failed. Patients with adhesive small bowel obstruction were given trial conservative treatment unless there was fear of bowel strangulation. Those responded in the initial 48 h had conservative treatment continued. Patients who showed no improvement in the initial 48 h were given 100 mL of gastrografin through nasogastric tube followed by serial abdominal radiographs. Patients with the contrast appeared in large bowel within 24 h were regarded as having partial obstruction and conservative treatment was continued. Patients in which the contrast failed to reach large bowel within 24 h were considered to have complete obstruction and laparotomy was performed. Two hundred and twelve patients with 245 episodes of adhesive obstruction were included. Fifteen patients were operated on soon after admission due to fear of strangulation. One hundred and eighty-six episodes of obstruction showed improvement in the initial 48 h and conservative treatment was continued. Two patients had subsequent operations because of persistent obstruction. Forty-four episodes of obstruction showed no improvement within 48 h and gastrografin was administered. Seven patients underwent complete obstruction surgery. Partial obstruction was demonstrated in 37 other cases, obstruction resolved subsequently in all of them except one patient who required laparotomy because of persistent obstruction. The overall operative rate in this study was 10%. There was no complication that could be attributed to the use of gastrografin. The use of gastrografin in adhesive small bowel obstruction after unsuccessful conservative treatment is safe and reduces the need for surgical intervention.

  10. Joy and happiness: a simultaneous and evolutionary concept analysis.

    PubMed

    Cottrell, Laura

    2016-07-01

    To report a simultaneous and evolutionary analysis of the concepts of joy and long-term happiness. Joy and happiness are underrepresented in the nursing literature, though negative concepts are well represented. When mentioned in the literature, neither joy nor happiness is adequately defined, explained, or clearly understood. To promote further investigation of these concepts in nursing and to explore their relationship with health and healing, conceptual clarity is an essential first step. Concept analysis. The following databases were searched, without time restrictions, for articles in English: Academic Search Complete, Anthropology Plus; ATLA Religious Database with ATLASerials; Cumulative Index of Nursing and Allied Health Literature (CINAHL); Education Research Complete; Humanities International Complete; Psych EXTRA; and SocINDEX with Full Text. The final sample size consists of 61 articles and one book, published between 1978-2014. An adapted combination of Rodgers' Evolutionary Model and Haase et al.'s Simultaneous Concept Analysis (SCA) method. Though both are positive concepts, joy and happiness have significant differences. Attributes of joy describe a spontaneous, sudden and transient concept associated with connection, awareness, and freedom. Attributes of happiness describe a pursued, long-lasting, stable mental state associated with virtue and self-control. Further exploration of joy and happiness is necessary to ascertain their relationship with health and their value to nursing practice and theory development. Nurses are encouraged to consider the value of positive concepts to all areas of nursing. © 2016 John Wiley & Sons Ltd.

  11. Complete Transversal Disc Fracture in a Björk-Shiley Delrin Mitral Valve Prosthesis 43 Years After Implantation.

    PubMed

    González-Santos, Jose María; Arnáiz-García, María Elena; Dalmau-Sorlí, María José; Sastre-Rincón, Jose Alfonso; Hernández-Hernández, Jesús; Pérez-Losada, María Elena; Sagredo-Meneses, Víctor; López-Rodríguez, Javier

    2016-10-01

    A patient who underwent previous implantation of a mitral valve replacement with a Björk-Shiley Delrin (BSD) mitral valve prosthesis during infancy was admitted to our institution 43 years later after an episode of syncope and cardiac arrest. Under extreme hemodynamic instability, a mitral valve prosthetic dysfunction causing massive mitral regurgitation was identified. The patient underwent an emergent cardiac operation, and a complete disc fracture with partial disc migration was found. Exceptional cases of mechanical prosthetic heart valve fracture exist. We report the first case of complete transversal disc rupture of a BSD mitral valve prosthesis after the longest period of implantation ever reported in that position. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Perceived Maternal Parenting Styles, Cultural Values, and Prosocial Tendencies Among Mexican American Youth.

    PubMed

    Davis, Alexandra N; Carlo, Gustavo; Knight, George P

    2015-01-01

    The present study aimed to extend research on parenting and positive development of Latino youth. Participants were 207 Mexican American adolescents (M age = 10.9 years, SD = 0.83 years; 50% girls) who completed measures of their parents' supportive and firm parenting, their own endorsement of respect and traditional gender role values, and their tendency to engage in six forms of prosocial behaviors. Maternal nativity was also considered as an initial predictor of parenting, adolescents' cultural values, and adolescents' prosocial behaviors. Overall, the results demonstrated that maternal nativity was associated with traditional gender roles and specific forms of prosocial behaviors. Parenting dimensions were differentially associated with respect and traditional gender role values and prosocial behaviors. Cultural values, in turn, were associated with multiple forms of prosocial behaviors. Gender differences in the processes were also explored.

  13. Assessing Breast Cancer Risk with an Artificial Neural Network

    PubMed

    Sepandi, Mojtaba; Taghdir, Maryam; Rezaianzadeh, Abbas; Rahimikazerooni, Salar

    2018-04-25

    Objectives: Radiologists face uncertainty in making decisions based on their judgment of breast cancer risk. Artificial intelligence and machine learning techniques have been widely applied in detection/recognition of cancer. This study aimed to establish a model to aid radiologists in breast cancer risk estimation. This incorporated imaging methods and fine needle aspiration biopsy (FNAB) for cyto-pathological diagnosis. Methods: An artificial neural network (ANN) technique was used on a retrospectively collected dataset including mammographic results, risk factors, and clinical findings to accurately predict the probability of breast cancer in individual patients. Area under the receiver-operating characteristic curve (AUC), accuracy, sensitivity, specificity, and positive and negative predictive values were used to evaluate discriminative performance. Result: The network incorporating the selected features performed best (AUC = 0.955). Sensitivity and specificity of the ANN were respectively calculated as 0.82 and 0.90. In addition, negative and positive predictive values were respectively computed as 0.90 and 0.80. Conclusion: ANN has potential applications as a decision-support tool to help underperforming practitioners to improve the positive predictive value of biopsy recommendations. Creative Commons Attribution License

  14. Predictive value of bacterial analysis of laparotomy wounds.

    PubMed

    Minutolo, Mario; Blandino, Giovanna; Arena, Manuel; Licciardello, Alessio; Di Stefano, Biagio; Lanteri, Raffaele; Puleo, Stefano; Licata, Antonio; Minutolo, Vincenzo

    2014-01-01

    Despite improvements in antibiotic prophylaxis, surgical site infections represent the most common postoperative complication with important clinical consequences for patients. The hypothesis that a bacterial analysis of the surgical wound in the operating room could predict the likelihood of developing a clinical infection, and might allow a tailored and preemptive approach, aimed to reduce the consequences of an infection, seems appealing. We would like to present a prospective study on the predictive value of the bacterial analysis of laparotomy wounds. Seventy eight prospective patients undergoing surgery were included in the study. To evaluate the risk factors associated with increased rate of wound infection, we performed a bacterial analysis of the wound. 48 patients out of 78 (61%) had positive cultures. 23 patients out of 32 patients (72%) who didn't receive antibiotic prophylaxis were positive to the wound culture whereas 25 patients out of 46 patients (54%) grew positive cultures in the group of patients that received antibiotic prophylaxis. None of the 30 patients with negative cultures developed clinical infection. Only 6 patients out of 48 patients who had positive cultures (12.5%) developed wound infection. Clinical infection occurred in 5 patients who had gram-negative contamination of the wound. No clinical infection occurred in patients who had gram-positive contamination. Wound cultures and their positivity are predictive tools to identify the patients that are at risk to develop wound infection. The positive predictive value of the bacterial analysis of the wound was 12.5%. Abdominal surgery, Bacterial analysis, Wound infection.

  15. 40 CFR 63.5995 - What are my monitoring installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... paragraphs (a) and (b)(1) through (8) of this section. (1) Locate the temperature sensor in a position that provides a representative temperature. (2) For a non-cryogenic temperature range, use a temperature sensor... value, whichever is larger. (3) For a cryogenic temperature range, use a temperature sensor with a...

  16. 46 CFR 56.50-15 - Steam and exhaust piping.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... stress for the material shall not exceed that corresponding to the saturated steam temperature at drum... normal rated operating condition. In both cases, the value of allowable stress shall be selected using a... hot water for heating systems may not exceed 375 °F. (i) Where positive shutoff valves are fitted in...

  17. 40 CFR 63.2269 - What are my monitoring installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Locate the temperature sensor in a position that provides a representative temperature. (2) Use a temperature sensor with a minimum accuracy of 4 °F or 0.75 percent of the temperature value, whichever is... manufacturer's owners manual. Following the electronic calibration, you must conduct a temperature sensor...

  18. 40 CFR 63.4768 - What are the requirements for continuous parameter monitoring system installation, operation, and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Locate the temperature sensor in a position that provides a representative temperature. (ii) Use a temperature sensor with a measurement sensitivity of 4 degrees Fahrenheit or 0.75 percent of the temperature value, whichever is larger. (iii) Shield the temperature sensor system from electromagnetic interference...

  19. 40 CFR 63.4768 - What are the requirements for continuous parameter monitoring system installation, operation, and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Locate the temperature sensor in a position that provides a representative temperature. (ii) Use a temperature sensor with a measurement sensitivity of 4 degrees Fahrenheit or 0.75 percent of the temperature value, whichever is larger. (iii) Shield the temperature sensor system from electromagnetic interference...

  20. 40 CFR 63.2269 - What are my monitoring installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Locate the temperature sensor in a position that provides a representative temperature. (2) Use a temperature sensor with a minimum accuracy of 4 °F or 0.75 percent of the temperature value, whichever is... manufacturer's owners manual. Following the electronic calibration, you must conduct a temperature sensor...

  1. 40 CFR 63.2269 - What are my monitoring installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Locate the temperature sensor in a position that provides a representative temperature. (2) Use a temperature sensor with a minimum accuracy of 4 °F or 0.75 percent of the temperature value, whichever is... manufacturer's owners manual. Following the electronic calibration, you must conduct a temperature sensor...

  2. Inducing the Einstein action in QCD-like theories

    NASA Astrophysics Data System (ADS)

    Donoghue, John F.; Menezes, Gabriel

    2018-03-01

    We evaluate the induced value of Newton's constant which would arise in QCD. The ingredients are modern lattice results, perturbation theory and the operator product expansion. The resulting shift in the Planck mass is positive. A scaled-up version of such a theory may be part of a quantum field theory treatment of gravity.

  3. Controlling Costs. Managing Resources Module. Operational Management Programme. Second Edition.

    ERIC Educational Resources Information Center

    Hayter, Roy

    This self-study unit focuses on managing resources--materials, equipment, personnel, money, energy, time, and information. The material is designed primarily for those in a supervisory or junior management position working within their company's policies and systems. The unit may be of value to the small business proprietor, as an introduction to…

  4. The cost of conversion in robotic and laparoscopic colorectal surgery.

    PubMed

    Cleary, Robert K; Mullard, Andrew J; Ferraro, Jane; Regenbogen, Scott E

    2018-03-01

    Conversion from minimally invasive to open colorectal surgery remains common and costly. Robotic colorectal surgery is associated with lower rates of conversion than laparoscopy, but institutions and payers remain concerned about equipment and implementation costs. Recognizing that reimbursement reform and bundled payments expand perspectives on cost to include the entire surgical episode, we evaluated the role of minimally invasive conversion in total payments. This is an observational study from a linked data registry including clinical data from the Michigan Surgical Quality Collaborative and payment data from the Michigan Value Collaborative between July 2012 and April 2015. We evaluated colorectal resections initiated with open and minimally invasive approaches, and compared reported risk-adjusted and price-standardized 30-day episode payments and their components. We identified 1061 open, 1604 laparoscopic, and 275 robotic colorectal resections. Adjusted episode payments were significantly higher for open operations than for minimally invasive procedures completed without conversion ($19,489 vs. $15,518, p < 0.001). The conversion rate was significantly higher with laparoscopic than robotic operations (15.1 vs. 7.6%, p < 0.001). Adjusted episode payments for minimally invasive operations converted to open were significantly higher than for those completed by minimally invasive approaches ($18,098 vs. $15,518, p < 0.001). Payments for operations completed robotically were greater than those completed laparoscopically ($16,949 vs. $15,250, p < 0.001), but the difference was substantially decreased when conversion to open cases was included ($16,939 vs. $15,699, p = 0.041). Episode payments for open colorectal surgery exceed both laparoscopic and robotic minimally invasive options. Conversion to open surgery significantly increases the payments associated with minimally invasive colorectal surgery. Because conversion rates in robotic colorectal operations are half of those in laparoscopy, the excess expenditures attributable to robotics are attenuated by consideration of the cost of conversions.

  5. Evaluation of an interlaced triple procedure: penetrating keratoplasty, extracapsular cataract extraction, and nonopen-sky intraocular lens implantation.

    PubMed

    Yang, Shuo; Wang, Bin; Zhang, Yangyang; Zhai, Hualei; Wang, Junyi; Wang, Shuang; Xie, Lixin

    2017-09-01

    To evaluate an interlaced triple procedure that involved penetrating keratoplasty (PKP), extracapsular cataract extraction (ECCE) using diathermy capsulotomy, and nonopen-sky intraocular lens (IOL) implantation.This retrospective study involved data from 34 patients who were diagnosed with severe corneal opacities and cataracts. These patients were divided into an interlaced procedure group (21 patients) and a traditional procedure group (13 patients). In the interlaced group, the method of continuous curvilinear capsulorhexis (CCC) was completed via diathermy capsulotomy. The donor corneal button was sutured at 8 positions (at equal intervals) using 10-0 nylon sutures, and the IOL was inserted into the capsular bag using a closed anterior chamber approach at the 10:30 to 12 o'clock positions between the sutures. In the traditional group, CCC was completed using side-port capsular forceps, and the IOL was implanted using an open anterior chamber approach.In the interlaced group, the CCC, open-sky, and total operation times were significantly shorter than in the traditional group (P < .05). Neither the best-corrected visual acuity (BCVA) nor corneal endothelial cell density was significantly different between the groups at 1 and 6 months after the operation.This interlaced triple procedure for the treatment of corneal diseases with cataracts appears to be feasible and practical.

  6. Coulomb branch operators and mirror symmetry in three dimensions

    NASA Astrophysics Data System (ADS)

    Dedushenko, Mykola; Fan, Yale; Pufu, Silviu S.; Yacoby, Ran

    2018-04-01

    We develop new techniques for computing exact correlation functions of a class of local operators, including certain monopole operators, in three-dimensional N=4 abelian gauge theories that have superconformal infrared limits. These operators are position-dependent linear combinations of Coulomb branch operators. They form a one-dimensional topological sector that encodes a deformation quantization of the Coulomb branch chiral ring, and their correlation functions completely fix the ( n ≤ 3)-point functions of all half-BPS Coulomb branch operators. Using these results, we provide new derivations of the conformal dimension of half-BPS monopole operators as well as new and detailed tests of mirror symmetry. Our main approach involves supersymmetric localization on a hemisphere HS 3 with half-BPS boundary conditions, where operator insertions within the hemisphere are represented by certain shift operators acting on the HS 3 wavefunction. By gluing a pair of such wavefunctions, we obtain correlators on S 3 with an arbitrary number of operator insertions. Finally, we show that our results can be recovered by dimensionally reducing the Schur index of 4D N=2 theories decorated by BPS 't Hooft-Wilson loops.

  7. Liver enzymes and blood metabolites in a population of free-ranging red deer (Cervus elaphus) naturally infected with Fascioloides magna.

    PubMed

    Severin, K; Mašek, T; Janicki, Z; Konjević, D; Slavica, A; Marinculić, A; Martinković, F; Vengušt, G; Džaja, P

    2012-06-01

    We investigated the effects of Fascioloides magna infection on the serum biochemistry values of the naturally infected red deer population in eastern Croatia. The investigation was performed on 47 red deer with F. magna infection confirmed patho-anatomically in 27 animals (57.4%). Fibrous capsules and migratory lesions were found in 14 deer while only fibrous capsules without migratory lesions were found in 13 deer. In 13 deer both immature and mature flukes were found, in 5 deer only immature flukes were found and in 9 deer only mature flukes were found. Fascioloides magna infected deer with fibrous capsules and migratory lesions had significantly higher values for lactate dehydrogenase (LDH), glutamate dehydrogenase (GLDH) and globulin, and lower values for albumin/globulin ratio and glucose compared to uninfected deer. Fascioloides magna infected deer with fibrous capsules without the presence of migratory lesions had higher values for alanine aminotransferase (ALT) and globulin, and lower values for albumin/globulin ratio and glucose, than the uninfected deer. The number of immature flukes was positively correlated with values of aspartate aminotransferase (AST), γ-glutamyltransferase (GGT), LDH, GLDH, urea and triglycerides. The number of migratory lesions was positively correlated with GGT, GLDH, globulin and urea values. The creatinine value was positively correlated with the number of mature flukes. The trial showed that F. magna infection causes significant changes in serum biochemistry. Moreover, these changes do not completely resemble changes following F. hepatica infection. Further investigation of changes in liver enzymes and other serum metabolites in controlled, experimentally induced fascioloidosis in red deer is needed to better understand the pathogenesis of F. magna.

  8. Review of the role of sentinel node biopsy in cutaneous head and neck melanoma.

    PubMed

    Roy, Jennifer M; Whitfield, Robert J; Gill, P Grantley

    2016-05-01

    Sentinel node biopsy (SNB) is recommended for selected melanoma patients in many parts of the world. This review examines the evidence surrounding the accuracy and prognostic value of SNB and completion neck dissection in head and neck melanoma. Sentinel nodes were identified in an average of 94.7% of head and neck cases compared with 95.3-100% in all melanoma cases. More false-negative sentinel nodes were found in head and neck cases. A positive sentinel node was associated with both lower disease-free survival (53.4 versus 83.2%) and overall survival (40 versus 84%). We conclude that SNB should be offered to all patients with intermediate and high-risk melanomas in the head and neck area. To date, evidence does not exist to demonstrate the safety of avoiding completion lymph node dissection in sentinel node-positive patients with head and neck melanoma. © 2015 Royal Australasian College of Surgeons.

  9. What You Don't Know Can Hurt You: Missing Data and Partial Credit Model Estimates

    PubMed Central

    Thomas, Sarah L.; Schmidt, Karen M.; Erbacher, Monica K.; Bergeman, Cindy S.

    2017-01-01

    The authors investigated the effect of Missing Completely at Random (MCAR) item responses on partial credit model (PCM) parameter estimates in a longitudinal study of Positive Affect. Participants were 307 adults from the older cohort of the Notre Dame Study of Health and Well-Being (Bergeman and Deboeck, 2014) who completed questionnaires including Positive Affect items for 56 days. Additional missing responses were introduced to the data, randomly replacing 20%, 50%, and 70% of the responses on each item and each day with missing values, in addition to the existing missing data. Results indicated that item locations and person trait level measures diverged from the original estimates as the level of degradation from induced missing data increased. In addition, standard errors of these estimates increased with the level of degradation. Thus, MCAR data does damage the quality and precision of PCM estimates. PMID:26784376

  10. Using Tablet Computers with Elementary School Students with Special Needs: The Practices and Perceptions of Special Education Teachers and Teacher Assistants

    ERIC Educational Resources Information Center

    Johnson, Genevieve Marie

    2013-01-01

    Twelve special education teachers and teacher assistants who have instructional experience using iPads with children with special needs completed a survey that queried their practices and perceptions. In general, teachers and assistants were extremely positive about the value of iPads for children with special needs, particularly for children with…

  11. Adsorption and leaching behaviour of bispyribac-sodium in soils.

    PubMed

    Singh, Neera; Singh, S B

    2015-01-01

    Adsorption-desorption of the herbicide bispyribac-sodium was studied in four Indian soil types. Bispyribac-sodium was poorly adsorbed in the four soils and adsorption decreased with an increase in the herbicide concentration in solution. Freundlich adsorption coefficient (Kf) values for bispyribac-sodium ranged between 0.37 and 0.87. Slope (1/n) values varied from 0.2 to 0.31 suggesting that bispyribac-sodium adsorption was highly dependent on its initial concentration in solution. Bispyribac-sodium adsorption showed a positive correlation with soil pH (r = 0.809) and clay content (r = 0.699) while no correlation was observed with the organic carbon (r = 0.063) content. Sorbed herbicide was completely desorbed during a single desorption step suggesting that the herbicide was bound by weak adsorptive forces. Leaching studies of herbicide in soil 1 packed column indicated complete loss of soil applied herbicide under a simulated rainfall equivalent to 162 mm.

  12. Sweet taste liking is associated with impulsive behaviors in humans

    PubMed Central

    Weafer, Jessica; Burkhardt, Anne; de Wit, Harriet

    2014-01-01

    Evidence from both human and animal studies suggests that sensitivity to rewarding stimuli is positively associated with impulsive behaviors, including both impulsive decision making and inhibitory control. The current study examined associations between the hedonic value of a sweet taste and two forms of impulsivity (impulsive choice and impulsive action) in healthy young adults (N = 100). Participants completed a sweet taste test in which they rated their liking of various sweetness concentrations. Subjects also completed measures of impulsive choice (delay discounting), and impulsive action (go/no-go task). Subjects who discounted more steeply (i.e., greater impulsive choice) liked the high sweetness concentration solutions more. By contrast, sweet liking was not related to impulsive action. These findings indicate that impulsive choice may be associated with heightened sensitivity to the hedonic value of a rewarding stimulus, and that these constructs might share common underlying neurobiological mechanisms. PMID:24987343

  13. Object detection with a multistatic array using singular value decomposition

    DOEpatents

    Hallquist, Aaron T.; Chambers, David H.

    2014-07-01

    A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across a surface and that travels down the surface. The detection system converts the return signals from a time domain to a frequency domain, resulting in frequency return signals. The detection system then performs a singular value decomposition for each frequency to identify singular values for each frequency. The detection system then detects the presence of a subsurface object based on a comparison of the identified singular values to expected singular values when no subsurface object is present.

  14. Delay banking for air traffic management

    NASA Technical Reports Server (NTRS)

    Green, Steven M. (Inventor)

    2007-01-01

    A method and associated system for time delay banking for aircraft arrival time, aircraft departure time and/or en route flight position. The delay credit value for a given flight may decrease with passage of time and may be transferred to or traded with other flights having the same or a different user (airline owner or operator). The delay credit value for a given aircraft flight depends upon an initial delay credit value, which is determined by a central system and depends upon one or more other flight characteristics. Optionally, the delay credit value decreases with passage of time. Optionally, a transaction cost is assessed against a delay credit value that is used on behalf of another flight with the same user or is traded with a different user.

  15. Diagnostic accuracy of bedside swallow evaluation versus videofluoroscopy to assess dysphagia in individuals with tetraplegia.

    PubMed

    Shem, Kazuko L; Castillo, Kathleen; Wong, Sandra Lynn; Chang, James; Kao, Ming-Chih; Kolakowsky-Hayner, Stephanie A

    2012-04-01

    To assess the accuracy of bedside swallow evaluation (BSE) compared with videofluorosopic swallow study (VFSS) in diagnosing dysphagia in individuals with tetraplegia due to spinal cord injury (SCI). A prospective diagnostic accuracy study according to STAndards for the Reporting of Diagnostic accuracy studies (STARD) criteria. A county hospital with acute inpatient SCI unit. Thirty-nine subjects with SCI and tetraplegia were enrolled. All of the subjects underwent BSE, and 26 subjects completed the VFSS. Individuals with SCI underwent a BSE followed by a VFSS within 72 hours of the BSE. The subjects were diagnosed as having dysphagia if they had positive findings in either BSE or VFSS. Sensitivity, specificity, and positive and negative predictive values were calculated by using VFSS as the criterion standard. Fifteen subjects (38%) were diagnosed as having dysphagia based on the BSE results. Among the subjects who completed the VFSS, 11 were diagnosed with dysphagia (42%) and 4 were diagnosed with aspiration (10%). Of the 26 subjects who completed both BSE and VFSS, only 1 subject was diagnosed differently compared with BSE (3.8%). Different diet recommendations were made in 4 cases after VFSS versus BSE. Different liquid recommendations were made in 8 cases after VFSS versus BSE. Sensitivity of BSE was 100% (95% confidence interval [CI], 71.5%-100%), specificity was 93.3% (95% CI, 68.1%-99.8%). A positive predictive value of BSE was 91.7% (95% CI, 61.5%-100%), and the negative predictive value was 100% (95% CI, 76.8%-100%). Dysphagia is present in approximately 38% of individuals with acute tetraplegia. Because only one of the 21 subjects was diagnosed differently based on VFSS, we believe that BSE is an appropriate screening tool for dysphagia for individuals with cervical SCI. However, VFSS provided additional information on diet and liquid recommendations, so there appears to be an important clinical role for the VFSS. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  16. Alaskan refiner raced against winter to relocate vacuum unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gdula, L.M.; Wentworth, J.A.

    In late November 1994, San Antonio-based Tesoro Petroleum Corp. and Litwin Engineers and Constructors Inc. completed the relocation and refurbishment of a $25 million vacuum unit at Tesoro`s 72,000 b/d Kenai refinery. The addition of the vacuum distillation unit is a critical component in Tesoro`s market-driven strategy to enhance operating profits by maximizing production of higher-margin products such as gasoline and jet fuel. With its new vacuum distillation unit, Tesoro has reduced production of lower-value residual fuel oil while recovering more lighter, high-value material. The paper discusses the economic and strategic merits of purchasing and relocating an existing vacuum unit,more » the project schedule, new equipment, dismantling and transport, installation, tie-ins and start-up, products, operating changes, corrosion concerns, off gas, steam generation, design changes, environmental issues, reporting requirements, and accomplishments.« less

  17. Building a world-class A/P function: how UPMC went paperless.

    PubMed

    DeLuca, Michael; Smith, Corey

    2010-03-01

    UPMC engaged people, processes, and technology to move its A/P function from a highly manual, paper-based operation to a completely automated process. UPMC's CFO hired a chief supply chain officer to develop a strategic plan, and UPMC named a value analysis team to gain clinician buy-in. UPMC automated A/P by enabling receipt of electronic invoices. UPMC streamlined its processes for invoices.

  18. Intrinsic Remediation Engineering Evaluation/Cost Analysis for Car Care Center at Bolling Air Force Base, Washington, DC

    DTIC Science & Technology

    1997-01-01

    supplemented using established literature values for similar aquifer materials . The groundwater sampling activities and analytical results from both...subsurface materials recovered. Observed soil classification types compared very favorably to the soil classifications determined by the CPT tests. 0 2.1.5...other similar substances were handled in a manner consistent with accepted safety procedures and standard operating practices. Well completion materials

  19. Archaeological Investigations on the San Antonio Terrace, Vandenberg Air Force Base, California, in Connection with MX Facilities Construction. Appendix II. Historical Overview of the Study Area.

    DTIC Science & Technology

    1984-01-01

    who took on the values of the Mexican culture. Yet, as opportunities expanded under American rule, he displayed entrepreneurship and the know-how that...completed it extended 250 feet out into the ocean (Deeds B-280; 0-542). Lompoc Landing operated under a franchise granted by the County Board of

  20. Contingent use of fetal fibronectin testing and cervical length measurement in women with preterm labour.

    PubMed

    Audibert, François; Fortin, Suzanne; Delvin, Edgard; Djemli, Anissa; Brunet, Suzanne; Dubé, Johanne; Fraser, William D

    2010-04-01

    To evaluate the contingent use of fetal fibronectin (fFN) testing and cervical length (CL) measurement to predict preterm delivery, and to validate the use of phosphorylated IGFBP-1 as a predictor of preterm delivery. We recruited 71 women with a clinical diagnosis of preterm labour between 24 and 34 weeks, and tested for the presence of fFN and IGFBP-1 in the cervicovaginal secretions of all women immediately before CL measurement. Among the 66 women with complete outcome, four were excluded from the final analysis as two had assessment for fFN but no CL measurement, and another two had CL measured but no screening for fFN. Among 62 women with complete results, the mean gestational age at recruitment was 29.4 +/- 2.5 weeks. Six women (9.6%) delivered within two weeks of assessment, and 14 (22.5%) delivered before 34 weeks. A positive fFN test resulted in a sensitivity of 83%, a specificity of 84%, a positive predictive value of 36%, and a negative predictive value of 98% for delivery within two weeks; for CL < 25 mm, these figures were 50%, 52%, 10%, and 91%, respectively, and for a positive IGFBP-1, they were 17%, 93%, 20%, and 91%, respectively. A policy of contingent use of fFN (in which the test was assumed to be positive if CL < or = 15 mm, and fFN was only measured if the CL was between 16 and 30 mm) gave sensitivity, specificity, positive and negative predictive values of 80%, 61%, 17%, and 97%, respectively for delivery within two weeks. Using this contingent use protocol, only one third of women needed fFN screening after CL measurement. In this study, IGFBP-1 screening did not predict preterm delivery and fFN screening provided the best predictive capacity. A policy of contingent use of testing for fFN after CL measurement, or contingent use of CL measurement after fFN screening (depending on available resources) is a promising approach to limit use of resources.

  1. Pioneer unmanned air vehicle accomplishments during Operation Desert Storm

    NASA Astrophysics Data System (ADS)

    Christner, James H.

    1991-12-01

    This paper will describe the accomplishments and lessons learned of the Pioneer Unmanned Air Vehicle (UAV) during Operations Desert Shield and Desert Storm. The Pioneer UAV has been deployed with three branches of the U.S. military (USA, USN, and USMC) for the past four years. Although the system has compiled over 6,000 flight hours, the recent conflict in the Gulf is the first opportunity to demonstrate its true value in a combat scenario. In a relatively short time (42 days), 307 flights and 1,011 flight hours were completed on Operation Desert Storm. This, coupled with the accuracy of various weapons systems that Pioneer observed/cued for, resulted in timely target engagements. This paper will chronicle the Pioneer deployment and accomplishments on Operations Desert Shield and Desert Storm. Various employment methods, tactics, doctrine, and lessons learned will be presented.

  2. Hydrologic Tests at Characterization Wells R-9i, R-13, R-19, R-22, and R-31, Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    S.G.McLin; W.J. Stone

    2004-06-01

    Hydrologic information is essential for environmental efforts at Los Alamos National Laboratory. Testing at new characterization wells being drilled to the regional aquifer (''R wells'') to improve the conceptual hydrogeologic model of the Pajarito Plateau is providing such information. Field tests were conducted on various zones of saturation penetrated by the R wells to collect data needed for determining hydraulic properties. This document provides details of the design and execution of testing as well as an analysis of data for five new wells: R-9i, R-13, R-19, R-22, and R-31. One well (R-13) was evaluated by a pumping test and themore » rest (R-9i, R-19, R-22, and R-31) were evaluated by injection tests. Characterization well R-9i is located in Los Alamos Canyon approximately 0.3 mi west of the Route 4/Route 502 intersection. It was completed at a depth of 322 ft below ground surface (bgs) in March 2000. This well was constructed with two screens positioned below the regional water table. Both screens were tested. Screen 1 is completed at about 189-200 ft bgs in fractured basalt, and screen 2 is completed at about 270-280 ft bgs in massive basalt. Specific capacity analysis of the screen 1 data suggests that the fractured basalt has a transmissivity (T) of 589 ft{sup 2}/day and corresponds to a hydraulic conductivity (K) of 7.1 ft/day based on a saturated thickness of 83 ft. The injection test data from the massive basalt near screen 2 were analyzed by the Bouwer-Rice slug test methodology and suggest that K is 0.11 ft/day, corresponding to a T of about 2.8 ft{sup 2}/day based on a saturated thickness of 25 ft. Characterization well R-13 is located in Mortandad Canyon just west of the eastern Laboratory boundary. It was completed at a depth of 1029 ft bgs in February 2002. This well was constructed with one 60-ft long screen positioned about 125 ft below the regional water table. This screen is completed at about 958-1019 ft bgs and straddles the geologic contact between the Puye fanglomerate and unassigned pumiceous units. The specific capacity analysis of a 12 minute pumping test indicates that the Puye fanglomerates near the R-13 screen have a T of 5269 ft{sup 2}/day and correspond to a hydraulic conductivity (K) of 17.6 ft/day based on a saturated thickness of 300 ft. Characterization well R-19 is located east of firing site IJ in Technical Area (TA) 36 on the mesa between Three-mile and Potrillo Canyons. It was completed at a depth of 1885 ft bgs in April 2000. This well was constructed with two screens positioned above the regional water table and five screens positioned below the regional water table. Only the bottom two screens were tested. Screen 6 is completed at about 1727-1734 ft bgs in Puye fanglomerate, and screen 7 is completed at about 1832-1849 ft bgs in Puye fanglomerate. Specific capacity analysis of the screen 6 data suggests that T is about 6923 ft{sup 2}/day and corresponds to a K of 18.6 ft/day based on a saturated thickness of 373 ft. Specific capacity analysis of the screen 7 data suggests that T is about 8179 ft{sup 2}/day and corresponds to a K of 22.0 ft/day based on a saturated thickness of 373 ft. Characterization well R-22 is located on Mesita del Buey between Canada del Buey and Pajarito Canyons immediately east of Material Disposal Area (MDA) G in TA-54. It was completed at a depth of 1489 ft bgs in October 2000. This well was constructed with five screens positioned at or below the regional water table; however, only screens 2-5 were tested. Screen 1 is completed at the regional water table at about 872-914 ft bgs in Cerros del Rio basalt. Screen 2 is completed at about 947-989 ft bgs in Cerros del Rio basalt. Screen 3 is completed at about 1272-1279 ft bgs in Puye fanglomerate. Screen 4 is completed at about 1378-1452 ft bgs in older basalt. Screen 5 is completed at about 1447-1452 ft bgs in older fanglomerate. Bouwer-Rice analyses of the injection-test recovery data suggest K values of 0.04, 0.32, 0.54, and 0.27 ft/day for screens 2, 3, 4, and 5, respectively. These values correspond to T values of 2.8, 15.8, 26.5, and 11.6 ft{sup 2}/day, respectively, for screens 2, 3, 4, and 5. These analyses are based on saturated thicknesses of 69.5 ft, 49.4 ft, 49.0 ft, and 43.0 ft, respectively. Characterization well R-31 is located at TA-39 in the north fork of lower Ancho Canyon. It was completed at a depth of 1103 ft bgs in April 2000. This well was constructed with one screen positioned above the regional water table, and four screens position at or below the regional water table.« less

  3. Mate call as reward: Acoustic communication signals can acquire positive reinforcing values during adulthood in female zebra finches (Taeniopygia guttata).

    PubMed

    Hernandez, Alexandra M; Perez, Emilie C; Mulard, Hervé; Mathevon, Nicolas; Vignal, Clémentine

    2016-02-01

    Social stimuli can have rewarding properties and promote learning. In birds, conspecific vocalizations like song can act as a reinforcer, and specific song variants can acquire particular rewarding values during early life exposure. Here we ask if, during adulthood, an acoustic signal simpler and shorter than song can become a reward for a female songbird because of its particular social value. Using an operant choice apparatus, we showed that female zebra finches display a preferential response toward their mate's calls. This reinforcing value of mate's calls could be involved in the maintenance of the monogamous pair-bond of the zebra finch. (c) 2016 APA, all rights reserved).

  4. Position dependent mass Schroedinger equation and isospectral potentials: Intertwining operator approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Midya, Bikashkali; Roy, B.; Roychoudhury, R.

    2010-02-15

    Here, we have studied first- and second-order intertwining approaches to generate isospectral partner potentials of position dependent (effective) mass Schroedinger equation. The second-order intertwiner is constructed directly by taking it as second-order linear differential operator with position dependent coefficients, and the system of equations arising from the intertwining relationship is solved for the coefficients by taking an ansatz. A complete scheme for obtaining general solution is obtained, which is valid for any arbitrary potential and mass function. The proposed technique allows us to generate isospectral potentials with the following spectral modifications: (i) to add new bound state(s), (ii) to removemore » bound state(s), and (iii) to leave the spectrum unaffected. To explain our findings with the help of an illustration, we have used point canonical transformation to obtain the general solution of the position dependent mass Schrodinger equation corresponding to a potential and mass function. It is shown that our results are consistent with the formulation of type A N-fold supersymmetry [T. Tanaka, J. Phys. A 39, 219 (2006); A. Gonzalez-Lopez and T. Tanaka, J. Phys. A 39, 3715 (2006)] for the particular cases N=1 and N=2, respectively.« less

  5. Water, ice, and meteorological measurements at South Cascade Glacier, Washington, 1986-1991 balance years

    USGS Publications Warehouse

    Krimmel, Robert M.

    2000-01-01

    Mass balance and climate variables are reported for South Cascade Glacier, Washington, for the years 1986-91. These variables include air temperature, precipitation, water runoff, snow accumulation, snow and ice melt terminus position, surface level, and ice speed. Data are reduced to daily and monthly values where appropriate. The glacier-averaged values of spring snow accumulation and fall net balance given in this report differ from previous results because amore complete analysis is made. Snow accumulation values for the1986-91 period ranged from 3.54 (water equivalent) meters in 1991 to2.04 meters in 1987. Net balance values ranged from 0.07 meters in1991 to -2.06 meters in 1987. The glacier became much smaller during the 1986-91 period and retreated a cumulative 50 meters.

  6. Three-dimensional surgical simulation.

    PubMed

    Cevidanes, Lucia H C; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael

    2010-09-01

    In this article, we discuss the development of methods for computer-aided jaw surgery, which allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3-dimensional surface models from cone-beam computed tomography, dynamic cephalometry, semiautomatic mirroring, interactive cutting of bone, and bony segment repositioning. A virtual setup can be used to manufacture positioning splints for intraoperative guidance. The system provides further intraoperative assistance with a computer display showing jaw positions and 3-dimensional positioning guides updated in real time during the surgical procedure. The computer-aided surgery system aids in dealing with complex cases with benefits for the patient, with surgical practice, and for orthodontic finishing. Advanced software tools for diagnosis and treatment planning allow preparation of detailed operative plans, osteotomy repositioning, bone reconstructions, surgical resident training, and assessing the difficulties of the surgical procedures before the surgery. Computer-aided surgery can make the elaboration of the surgical plan a more flexible process, increase the level of detail and accuracy of the plan, yield higher operative precision and control, and enhance documentation of cases. 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  7. Real option valuation of a decremental regulation service provided by electricity storage.

    PubMed

    Szabó, Dávid Zoltán; Martyr, Randall

    2017-08-13

    This paper is a quantitative study of a reserve contract for real-time balancing of a power system. Under this contract, the owner of a storage device, such as a battery, helps smooth fluctuations in electricity demand and supply by using the device to increase electricity consumption. The battery owner must be able to provide immediate physical cover, and should therefore have sufficient storage available in the battery before entering the contract. Accordingly, the following problem can be formulated for the battery owner: determine the optimal time to enter the contract and, if necessary, the optimal time to discharge electricity before entering the contract. This problem is formulated as one of optimal stopping, and is solved explicitly in terms of the model parameters and instantaneous values of the power system imbalance. The optimal operational strategies thus obtained ensure that the battery owner has positive expected economic profit from the contract. Furthermore, they provide explicit conditions under which the optimal discharge time is consistent with the overall objective of power system balancing. This paper also carries out a preliminary investigation of the 'lifetime value' aggregated from an infinite sequence of these balancing reserve contracts. This lifetime value, which can be viewed as a single project valuation of the battery, is shown to be positive and bounded. Therefore, in the long run such reserve contracts can be beneficial to commercial operators of electricity storage, while reducing some of the financial and operational risks in power system balancing.This article is part of the themed issue 'Energy management: flexibility, risk and optimization'. © 2017 The Author(s).

  8. Sensitivity and specificity of subacute computerized neurocognitive testing and symptom evaluation in predicting outcomes after sports-related concussion.

    PubMed

    Lau, Brian C; Collins, Michael W; Lovell, Mark R

    2011-06-01

    Concussions affect an estimated 136 000 high school athletes yearly. Computerized neurocognitive testing has been shown to be appropriately sensitive and specific in diagnosing concussions, but no studies have assessed its utility to predict length of recovery. Determining prognosis during subacute recovery after sports concussion will help clinicians more confidently address return-to-play and academic decisions. To quantify the prognostic ability of computerized neurocognitive testing in combination with symptoms during the subacute recovery phase from sports-related concussion. Cohort study (prognosis); Level of evidence, 2. In sum, 108 male high school football athletes completed a computer-based neurocognitive test battery within 2.23 days of injury and were followed until returned to play as set by international guidelines. Athletes were grouped into protracted recovery (>14 days; n = 50) or short-recovery (≤14 days; n = 58). Separate discriminant function analyses were performed using total symptom score on Post-Concussion Symptom Scale, symptom clusters (migraine, cognitive, sleep, neuropsychiatric), and Immediate Postconcussion Assessment and Cognitive Testing neurocognitive scores (verbal memory, visual memory, reaction time, processing speed). Multiple discriminant function analyses revealed that the combination of 4 symptom clusters and 4 neurocognitive composite scores had the highest sensitivity (65.22%), specificity (80.36%), positive predictive value (73.17%), and negative predictive value (73.80%) in predicting protracted recovery. Discriminant function analyses of total symptoms on the Post-Concussion Symptom Scale alone had a sensitivity of 40.81%; specificity, 79.31%; positive predictive value, 62.50%; and negative predictive value, 61.33%. The 4 symptom clusters alone discriminant function analyses had a sensitivity of 46.94%; specificity, 77.20%; positive predictive value, 63.90%; and negative predictive value, 62.86%. Discriminant function analyses of the 4 computerized neurocognitive scores alone had a sensitivity of 53.20%; specificity, 75.44%; positive predictive value, 64.10%; and negative predictive value, 66.15%. The use of computerized neurocognitive testing in conjunction with symptom clusters results improves sensitivity, specificity, positive predictive value, and negative predictive value of predicting protracted recovery compared with each used alone. There is also a net increase in sensitivity of 24.41% when using neurocognitive testing and symptom clusters together compared with using total symptoms on Post-Concussion Symptom Scale alone.

  9. The Perception and Costs of the Interview Process for Plastic Surgery Residency Programs: Can the Process Be Streamlined?

    PubMed

    Susarla, Srinivas M; Swanson, Edward W; Slezak, Sheri; Lifchez, Scott D; Redett, Richard J

    2017-01-01

    The purpose of this study was to assess applicant perceptions and costs associated with the interview process for plastic surgery residency positions. This was a cross-sectional survey of applicants to the integrated- and independent-track residencies at the authors' institution. All applicants who were interviewed were invited to complete a Web-based survey on costs and perceptions of various components of the interview process. Descriptive and bivariate statistics were computed to compare applicants to the two program tracks. Fifty-three applicants were interviewed for residency positions; 48 completed a survey (90.5 percent response rate). Thirty-four applicants were candidates for the integrated program; 16 applicants were candidates for the independent program. The program spent $2763 per applicant interviewed; 63 percent of applicants spent more than $5000 on the interview process. More than 70 percent of applicants missed more than 7 days of work to attend interviews. Independent applicants felt less strongly that interviews were critical to the selection process and placed less value on physically visiting the hospital and direct, in-person interaction. Applicants placed little value on program informational talks. Applicants who had experience with virtual interviews felt more positively about the format of a video interview relative to those who did not. The residency interview process is resource intensive for programs and applicants. Removing informational talks may improve the process. Making physical tours and in-person interviews optional are other alternatives that merit future study.

  10. Predictive genetic testing for the identification of high-risk groups: a simulation study on the impact of predictive ability

    PubMed Central

    2011-01-01

    Background Genetic risk models could potentially be useful in identifying high-risk groups for the prevention of complex diseases. We investigated the performance of this risk stratification strategy by examining epidemiological parameters that impact the predictive ability of risk models. Methods We assessed sensitivity, specificity, and positive and negative predictive value for all possible risk thresholds that can define high-risk groups and investigated how these measures depend on the frequency of disease in the population, the frequency of the high-risk group, and the discriminative accuracy of the risk model, as assessed by the area under the receiver-operating characteristic curve (AUC). In a simulation study, we modeled genetic risk scores of 50 genes with equal odds ratios and genotype frequencies, and varied the odds ratios and the disease frequency across scenarios. We also performed a simulation of age-related macular degeneration risk prediction based on published odds ratios and frequencies for six genetic risk variants. Results We show that when the frequency of the high-risk group was lower than the disease frequency, positive predictive value increased with the AUC but sensitivity remained low. When the frequency of the high-risk group was higher than the disease frequency, sensitivity was high but positive predictive value remained low. When both frequencies were equal, both positive predictive value and sensitivity increased with increasing AUC, but higher AUC was needed to maximize both measures. Conclusions The performance of risk stratification is strongly determined by the frequency of the high-risk group relative to the frequency of disease in the population. The identification of high-risk groups with appreciable combinations of sensitivity and positive predictive value requires higher AUC. PMID:21797996

  11. Carotid artery B-mode ultrasound image segmentation based on morphology, geometry and gradient direction

    NASA Astrophysics Data System (ADS)

    Sunarya, I. Made Gede; Yuniarno, Eko Mulyanto; Purnomo, Mauridhi Hery; Sardjono, Tri Arief; Sunu, Ismoyo; Purnama, I. Ketut Eddy

    2017-06-01

    Carotid Artery (CA) is one of the vital organs in the human body. CA features that can be used are position, size and volume. Position feature can used to determine the preliminary initialization of the tracking. Examination of the CA features can use Ultrasound. Ultrasound imaging can be operated dependently by an skilled operator, hence there could be some differences in the images result obtained by two or more different operators. This can affect the process of determining of CA. To reduce the level of subjectivity among operators, it can determine the position of the CA automatically. In this study, the proposed method is to segment CA in B-Mode Ultrasound Image based on morphology, geometry and gradient direction. This study consists of three steps, the data collection, preprocessing and artery segmentation. The data used in this study were taken directly by the researchers and taken from the Brno university's signal processing lab database. Each data set contains 100 carotid artery B-Mode ultrasound image. Artery is modeled using ellipse with center c, major axis a and minor axis b. The proposed method has a high value on each data set, 97% (data set 1), 73 % (data set 2), 87% (data set 3). This segmentation results will then be used in the process of tracking the CA.

  12. [Hygienic Inspections of Ventilation Systems Under Resting Conditions (According to DIN 1946-4:1999-03) - A Retrospective Assessment].

    PubMed

    Friedrich, Lena; Boeckelmann, Irina

    2018-01-11

    Hygienic and microbiologically sterile air quality is essential for successful guideline-based work in operating theatres. To ensure clean air and to reduce contamination during surgery, ventilation systems are indispensable. Ventilation systems should be especially designed to keep the number of particles and germs under statutory limits. Therefore, they must be operated to recognised standards of good practice and be periodically inspected and maintained. The objective of this study was to prove, through the analysis of observation outside surgery time (rest condition), the effects of ventilation systems on air quality in a medical facility. Measurements were taken in 34 operating theatres annually over a period of ten years outside surgery time (resting condition) but with the air ventilation system operating under full load. 29 operating theatres were provided with laminar air flow and five theatres with turbulent air flow systems. In each operating theatre, air cleanliness was analysed by measuring the amount of airborne particles and airborne germs. Measuring points were determined 10 mm beneath the supply-air ceiling in the centre of the operating theatre and at one position outside the supply-air ceiling. The number of airborne particles at the supply-air ceiling was between 0/m³ and 4,441/m³ of air and, as such, the limiting factor was never exceeded. However, airborne germ measurements of between 0 CFU/m³ and 200 CFU/m³ (CFU: colony forming units) demonstrated that the limiting factor for this criterion was exceeded in 10.9% of occasions. In general, the values in the middle of the room were higher than at the supply-air ceiling. There were significant differences (p < 0.001) between the values at the supply-air ceiling, the surgery table and the values outside the supply-air ceiling. The results show the positive impact of ventilation systems on the air cleanliness in operating theatres. However, laminar airflow systems seem to create cleaner air than conventional ventilation systems. The size of the supply-air ceiling plays an important role in the prevention of the contamination of the staff, the surgical field, the instrument table and the patient. However, the effect on surgical site infections has not been verified. Improved measuring methods should be considered. Georg Thieme Verlag KG Stuttgart · New York.

  13. Hawking effects as a noisy quantum channel

    NASA Astrophysics Data System (ADS)

    Ahn, Doyeol

    2018-01-01

    In this work, we have shown that the evolution of the bipartite entangled state near the black hole with the Hawking radiation can be described by a noisy quantum channel, having a complete positive map with an "operator sum representation." The entanglement fidelity is obtained in analytic form from the "operator sum representation." The bipartite entangled state becomes bipartite mixed Gaussian state as the black hole evaporates. By comparing negativity and entanglement monotone with the analytical form of the entanglement fidelity, we found that the negativity and the entanglement monotone for s = 1/2 provide the upper and the lower bounds of the entanglement fidelity, respectively.

  14. Medical chart validation of an algorithm for identifying multiple sclerosis relapse in healthcare claims.

    PubMed

    Chastek, Benjamin J; Oleen-Burkey, Merrikay; Lopez-Bresnahan, Maria V

    2010-01-01

    Relapse is a common measure of disease activity in relapsing-remitting multiple sclerosis (MS). The objective of this study was to test the content validity of an operational algorithm for detecting relapse in claims data. A claims-based relapse detection algorithm was tested by comparing its detection rate over a 1-year period with relapses identified based on medical chart review. According to the algorithm, MS patients in a US healthcare claims database who had either (1) a primary claim for MS during hospitalization or (2) a corticosteroid claim following a MS-related outpatient visit were designated as having a relapse. Patient charts were examined for explicit indication of relapse or care suggestive of relapse. Positive and negative predictive values were calculated. Medical charts were reviewed for 300 MS patients, half of whom had a relapse according to the algorithm. The claims-based criteria correctly classified 67.3% of patients with relapses (positive predictive value) and 70.0% of patients without relapses (negative predictive value; kappa 0.373: p < 0.001). Alternative algorithms did not improve on the predictive value of the operational algorithm. Limitations of the algorithm include lack of differentiation between relapsing-remitting MS and other types, and that it does not incorporate measures of function and disability. The claims-based algorithm appeared to successfully detect moderate-to-severe MS relapse. This validated definition can be applied to future claims-based MS studies.

  15. Linkage of microbial kinetics and bacterial community structure of MBR and hybrid MBBR-MBR systems to treat salinity-amended urban wastewater.

    PubMed

    Rodriguez-Sanchez, Alejandro; Leyva-Diaz, Juan Carlos; Gonzalez-Martinez, Alejandro; Poyatos, Jose Manuel

    2017-11-01

    Three pilot-scale bioreactors were started up and operated under salinity-amended urban wastewater feeding. The bioreactors were configured as membrane bioreactor and two different hybrid, moving bed biofilm reactor-membrane bioreactor and operated with a hydraulic retention time of 9.5 h, a solid residence time of 11.75 days and a total solids concentration of 2500 mg L -1 . The three systems showed excellent performance in suspended solids, BOD 5 , and COD removal (values of 96-100%, 97-99%, and 88-90%, respectively), but poor nitrogen removal (values of 20-30%). The bacterial community structure during the start-up phase and the stabilization phase were different, as showed by β-diversity analyses. The differences between aerobic and anoxic biomass-and between suspended and attached biomass-were higher at the start-up phase than at the stabilization phase. The start-up phase showed high abundances of Chiayiivirga (mean values around 3-12% relative abundance) and Luteimonas (5-8%), but in the stabilization phase, the domination belonged to Thermomonas (3-14%), Nitrobacter (3-7%), Ottowia (3-11.5%), and Comamonas (2-6%), among others. Multivariate redundancy analyses showed that Thermomonas and Nitrosomonas were positively correlated with fast autotrophic kinetics, while Caulobacter and Ottowia were positively correlated with fast heterotrophic kinetics. Nitrobacter, Rhodanobacter, and Comamonas were positively correlated with fast autotrophic and heterotrophic kinetics. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:1483-1495, 2017. © 2017 American Institute of Chemical Engineers.

  16. Relative reward effects on operant behavior: Incentive contrast, induction and variety effects

    PubMed Central

    Webber, E.S.; Chambers, N. E.; Kostek, J.A.; Mankin, D.E; Cromwell, H.C.

    2015-01-01

    Comparing different rewards automatically produces dynamic relative outcome effects on behavior. Each new outcome exposure is to an updated version evaluated relative to alternatives. Relative reward effects include incentive contrast, positive induction and variety effects. The present study utilized a novel behavioral design to examine relative reward effects on a chain of operant behavior using auditory cues. Incentive contrast is the most often examined effect and focuses on increases or decreases in behavioral performance after value upshifts (positive) or downshifts (negative) relative to another outcome. We examined the impact of comparing two reward outcomes in a repeated measures design with three sessions: a single outcome and a mixed outcome and a final single outcome session. Relative reward effects should be apparent when comparing trials for the identical outcome between the single and mixed session types. An auditory cue triggered a series of operant responses (nosepoke-leverpress-food retrieval), and we measured possible contrast effects for different reward magnitude combinations. We found positive contrast for trials with the greatest magnitude differential but positive induction or variety effects in other combinations. This behavioral task could be useful for analyzing environmental or neurobiological factors involved in reward comparisons, decision-making and choice during instrumental, goal-directed action. PMID:25979604

  17. On the Power of Abstract Interpretation

    NASA Technical Reports Server (NTRS)

    Reddy, Uday S.; Kamin, Samuel N.

    1991-01-01

    Increasingly sophisticated applications of static analysis place increased burden on the reliability of the analysis techniques. Often, the failure of the analysis technique to detect some information my mean that the time or space complexity of the generated code would be altered. Thus, it is important to precisely characterize the power of static analysis techniques. We follow the approach of Selur et. al. who studied the power of strictness analysis techniques. Their result can be summarized by saying 'strictness analysis is perfect up to variations in constants.' In other words, strictness analysis is as good as it could be, short of actually distinguishing between concrete values. We use this approach to characterize a broad class of analysis techniques based on abstract interpretation including, but not limited to, strictness analysis. For the first-order case, we consider abstract interpretations where the abstract domain for data values is totally ordered. This condition is satisfied by Mycroft's strictness analysis that of Sekar et. al. and Wadler's analysis of list-strictness. For such abstract interpretations, we show that the analysis is complete in the sense that, short of actually distinguishing between concrete values with the same abstraction, it gives the best possible information. We further generalize these results to typed lambda calculus with pairs and higher-order functions. Note that products and function spaces over totally ordered domains are not totally ordered. In fact, the notion of completeness used in the first-order case fails if product domains or function spaces are added. We formulate a weaker notion of completeness based on observability of values. Two values (including pairs and functions) are considered indistinguishable if their observable components are indistinguishable. We show that abstract interpretation of typed lambda calculus programs is complete up to this notion of indistinguishability. We use denotationally-oriented arguments instead of the detailed operational arguments used by Selur et. al.. Hence, our proofs are much simpler. They should be useful for further future improvements.

  18. Actual change and inaccurate recall contribute to posttraumatic growth following radiotherapy.

    PubMed

    Ransom, Sean; Sheldon, Kennon M; Jacobsen, Paul B

    2008-10-01

    People with cancer often report that they experience personal growth as a result of the disease, but such reports have unclear validity. Some suggest such growth results from Rogers's (1951) hypothesized organismic valuing process (OVP), an innate tendency for people to gravitate toward well-being; others suggest this growth may be a positive illusion resulting from temporal self-comparisons. To test these conceptualizations, the authors examined 83 individuals with Stages 0-III breast or prostate cancer. Patients completed measures of positive attributes and personal life goals before radiotherapy (Time 1) and after radiotherapy (Time 2). At Time 2, participants also attempted to recreate their Time 1 responses and completed a posttraumatic growth (PTG) measure. PTG was significantly related with actual increases (but not perceived increases) in the relative importance of intrinsic goals versus extrinsic goals and with perceived increases (but not actual increases) in positive attributes. These measures were unrelated to one another and thus explained unique variance in PTG. Data suggest that both actual change processes related to the OVP and biases in autobiographic recall may independently contribute to PTG reports. (c) 2008 APA, all rights reserved.

  19. q-bosons and the q-analogue quantized field

    NASA Technical Reports Server (NTRS)

    Nelson, Charles A.

    1995-01-01

    The q-analogue coherent states are used to identify physical signatures for the presence of a 1-analogue quantized radiation field in the q-CS classical limits where the absolute value of z is large. In this quantum-optics-like limit, the fractional uncertainties of most physical quantities (momentum, position, amplitude, phase) which characterize the quantum field are O(1). They only vanish as O(1/absolute value of z) when q = 1. However, for the number operator, N, and the N-Hamiltonian for a free q-boson gas, H(sub N) = h(omega)(N + 1/2), the fractional uncertainties do still approach zero. A signature for q-boson counting statistics is that (Delta N)(exp 2)/ (N) approaches 0 as the absolute value of z approaches infinity. Except for its O(1) fractional uncertainty, the q-generalization of the Hermitian phase operator of Pegg and Barnett, phi(sub q), still exhibits normal classical behavior. The standard number-phase uncertainty-relation, Delta(N) Delta phi(sub q) = 1/2, and the approximate commutation relation, (N, phi(sub q)) = i, still hold for the single-mode q-analogue quantized field. So, N and phi(sub q) are almost canonically conjugate operators in the q-CS classical limit. The q-analogue CS's minimize this uncertainty relation for moderate (absolute value of z)(exp 2).

  20. Evolving Self View and Body Image Concerns in Female Post-Operative Bariatric Surgery Patients.

    PubMed

    Perdue, Tamara O; Schreier, Ann; Swanson, Melvin; Neil, Janice; Carels, Robert

    2018-05-18

    This research study explores the experience of post-operative bariatric surgery patients as they adjust to diminished weight and differentiates that adjustment from the more general concept of body image. Bariatric surgery is an effective way to reduce weight and co-morbidities associated with obesity. Complete success requires that patients must adjust psychologically as they lose weight. If this does not occur, bariatric patients may experience a 'mind-body lag' in which the patient's internal body image lags behind the external changes. Hermans' Dialogical Self Theory of 'I-positions' is a foundation with which to understand this problem. Descriptive correlational study of post-operative bariatric patients explored the concept of 'I-obese' and 'I-ex-obese' in an effort to quantify previous qualitative findings and develop a survey questionnaire. Bariatric patients (N=55) between 18-30 month post-operative completed one hour interviews. Cluster analysis and Chi-square analysis compared mean scores and explored the prevalence of 'I-positions' and body image concerns in the participants. Cluster analysis of the survey data identified participants as falling into either 'I-obese', 'I-ex-obese' or 'mixed I-obese' categories. There were significantly higher body image concerns in the 'I-obese' participants than those identified as 'I-ex-obese'. The majority of female participants reported high body image concerns. There was no significant association with weight loss percentage. This research establishes a connection in this study sample of women who experience body image concerns and prolonged 'I-obese' identification 18 to 30 months after their bariatric surgery. To date, the primary measure of bariatric surgery success has focused almost exclusively on the amount of weight lost. Implementing psychological as well as physiological care however, may be the key to full recovery and long-term success. Practitioners can use this new information to plan effective pre- and post-operative psychological preparation and support. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

Top