Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-10
...] Medicare Program; Section 3113: The Treatment of Certain Complex Diagnostic Laboratory Tests Demonstration... code under the Treatment of Certain Complex Diagnostic Laboratory Tests Demonstration. The deadline for... interested parties of an opportunity to participate in the Treatment of Certain Complex Diagnostic Laboratory...
42 CFR 493.833 - Condition: Diagnostic immunology.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Diagnostic immunology. 493.833 Section 493.833 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... for Laboratories Performing Tests of Moderate Complexity (including the Subcategory), High Complexity...
42 CFR 493.833 - Condition: Diagnostic immunology.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Diagnostic immunology. 493.833 Section 493.833 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... for Laboratories Performing Tests of Moderate Complexity (including the Subcategory), High Complexity...
Clinical Laboratories – Production Factories or Specialized Diagnostic Centers
Tóth, Judit
2016-01-01
Since a large proportion of medical decisions are based on laboratory results, clinical laboratories should meet the increasing demand of clinicians and their patients. Huge central laboratories may process over 10 million tests annually; they act as production factories, measuring emergency and routine tests with sufficient speed and accuracy. At the same time, they also serve as specialized diagnostic centers where well-trained experts analyze and interpret special test results. It is essential to improve and constantly monitor this complex laboratory service, by several methods. Sample transport by pneumatic tube system, use of an advanced laboratory information system and point-of-care testing may result in decreased total turnaround time. The optimization of test ordering may result in a faster and more cost-effective laboratory service. Autovalidation can save time for laboratory specialists, when the analysis of more complex results requires their attention. Small teams of experts responsible for special diagnostic work, and their interpretative reporting according to predetermined principles, may help to minimize subjectivity of these special reports. Although laboratory investigations have become so diversely developed in the past decades, it is essential that the laboratory can provide accurate results relatively quickly, and that laboratory specialists can support the diagnosis and monitoring of patients by adequate interpretation of esoteric laboratory methods. PMID:27683528
Modeling Complex Workflow in Molecular Diagnostics
Gomah, Mohamed E.; Turley, James P.; Lu, Huimin; Jones, Dan
2010-01-01
One of the hurdles to achieving personalized medicine has been implementing the laboratory processes for performing and reporting complex molecular tests. The rapidly changing test rosters and complex analysis platforms in molecular diagnostics have meant that many clinical laboratories still use labor-intensive manual processing and testing without the level of automation seen in high-volume chemistry and hematology testing. We provide here a discussion of design requirements and the results of implementation of a suite of lab management tools that incorporate the many elements required for use of molecular diagnostics in personalized medicine, particularly in cancer. These applications provide the functionality required for sample accessioning and tracking, material generation, and testing that are particular to the evolving needs of individualized molecular diagnostics. On implementation, the applications described here resulted in improvements in the turn-around time for reporting of more complex molecular test sets, and significant changes in the workflow. Therefore, careful mapping of workflow can permit design of software applications that simplify even the complex demands of specialized molecular testing. By incorporating design features for order review, software tools can permit a more personalized approach to sample handling and test selection without compromising efficiency. PMID:20007844
Payne, Deborah A; Baluchova, Katarina; Peoc'h, Katell H; van Schaik, Ron H N; Chan, K C Allen; Maekawa, Masato; Mamotte, Cyril; Russomando, Graciela; Rousseau, François; Ahmad-Nejad, Parviz
2017-04-01
Multiple organizations produce guidance documents that provide opportunities to harmonize quality practices for diagnostic testing. The International Organization for Standardization ISO 15189 standard addresses requirements for quality in management and technical aspects of the clinical laboratory. One technical aspect addresses the complexities of the pre-examination phase prior to diagnostic testing. The Committee for Molecular Diagnostics of the International Federation for Clinical Chemistry and Laboratory Medicine (also known as, IFCC C-MD) conducted a survey of international molecular laboratories and determined ISO 15189 to be the most referenced guidance document. In this review, the IFCC C-MD provides case-based examples illustrating the value of select pre-examination processes as these processes relate to molecular diagnostic testing. Case-based examples in infectious disease, oncology, inherited disease and pharmacogenomics address the utility of: 1) providing information to patients and users, 2) designing requisition forms, 3) obtaining informed consent and 4) maintaining sample integrity prior to testing. The pre-examination phase requires extensive and consistent communication between the laboratory, the healthcare provider and the end user. The clinical vignettes presented in this paper illustrate the value of applying select ISO 15189 recommendations for general laboratory to the more specialized area of Molecular Diagnostics. Copyright © 2016 Elsevier B.V. All rights reserved.
[Lab-on-a-chip systems in the point-of-care diagnostics].
Szabó, Barnabás; Borbíró, András; Fürjes, Péter
2015-12-27
The need in modern medicine for near-patient diagnostics being able to accelerate therapeutic decisions and possibly replacing laboratory measurements is significantly growing. Reliable and cost-effective bioanalytical measurement systems are required which - acting as a micro-laboratory - contain integrated biomolecular recognition, sensing, signal processing and complex microfluidic sample preparation modules. These micro- and nanofabricated Lab-on-a-chip systems open new perspectives in the diagnostic supply chain, since they are able even for quantitative, high-precision and immediate analysis of special disease specific molecular markers or their combinations from a single drop of sample. Accordingly, crucial requirements regarding the instruments and the analytical methods are the high selectivity, extremely low detection limit, short response time and integrability into the healthcare information networks. All these features can make the hierarchical examination chain shorten, and revolutionize laboratory diagnostics, evolving a brand new situation in therapeutic intervention.
Costa, Pedro; Botelho, Ana; Couto, Isabel; Viveiros, Miguel; Inácio, João
2014-01-01
Nucleic acid testing (NAT) designate any molecular approach used for the detection, identification, and characterization of pathogenic microorganisms, enabling the rapid, specific, and sensitive diagnostic of infectious diseases, such as tuberculosis. These assays have been widely used since the 90s of the last century in human clinical laboratories and, subsequently, also in veterinary diagnostics. Most NAT strategies are based in the polymerase chain reaction (PCR) and its several enhancements and variations. From the conventional PCR, real-time PCR and its combinations, isothermal DNA amplification, to the nanotechnologies, here we review how the NAT assays have been applied to decipher if and which member of the Mycobacterium tuberculosis complex is present in a clinical sample. Recent advances in DNA sequencing also brought new challenges and have made possible to generate rapidly and at a low cost, large amounts of sequence data. This revolution with the high-throughput sequencing (HTS) technologies makes whole genome sequencing (WGS) and metagenomics the trendiest NAT strategies, today. The ranking of NAT techniques in the field of clinical diagnostics is rising, and we provide a SWOT (Strengths, Weaknesses, Opportunities, and Threats) analysis with our view of the use of molecular diagnostics for detecting tuberculosis in veterinary laboratories, notwithstanding the gold standard being still the classical culture of the agent. The complementary use of both classical and molecular diagnostics approaches is recommended to speed the diagnostic, enabling a fast decision by competent authorities and rapid tackling of the disease. PMID:25988157
Costa, Pedro; Botelho, Ana; Couto, Isabel; Viveiros, Miguel; Inácio, João
2014-01-01
Nucleic acid testing (NAT) designate any molecular approach used for the detection, identification, and characterization of pathogenic microorganisms, enabling the rapid, specific, and sensitive diagnostic of infectious diseases, such as tuberculosis. These assays have been widely used since the 90s of the last century in human clinical laboratories and, subsequently, also in veterinary diagnostics. Most NAT strategies are based in the polymerase chain reaction (PCR) and its several enhancements and variations. From the conventional PCR, real-time PCR and its combinations, isothermal DNA amplification, to the nanotechnologies, here we review how the NAT assays have been applied to decipher if and which member of the Mycobacterium tuberculosis complex is present in a clinical sample. Recent advances in DNA sequencing also brought new challenges and have made possible to generate rapidly and at a low cost, large amounts of sequence data. This revolution with the high-throughput sequencing (HTS) technologies makes whole genome sequencing (WGS) and metagenomics the trendiest NAT strategies, today. The ranking of NAT techniques in the field of clinical diagnostics is rising, and we provide a SWOT (Strengths, Weaknesses, Opportunities, and Threats) analysis with our view of the use of molecular diagnostics for detecting tuberculosis in veterinary laboratories, notwithstanding the gold standard being still the classical culture of the agent. The complementary use of both classical and molecular diagnostics approaches is recommended to speed the diagnostic, enabling a fast decision by competent authorities and rapid tackling of the disease.
Ren, Guomin; Krawetz, Roman
2015-01-01
The data explosion in the last decade is revolutionizing diagnostics research and the healthcare industry, offering both opportunities and challenges. These high-throughput "omics" techniques have generated more scientific data in the last few years than in the entire history of mankind. Here we present a brief summary of how "big data" have influenced early diagnosis of complex diseases. We will also review some of the most commonly used "omics" techniques and their applications in diagnostics. Finally, we will discuss the issues brought by these new techniques when translating laboratory discoveries to clinical practice.
Bertolaccini, Maria Laura; Amengual, Olga; Andreoli, Laura; Atsumi, Tatsuya; Chighizola, Cecilia B; Forastiero, Ricardo; de Groot, Philip; Lakos, Gabriella; Lambert, Marc; Meroni, Pierluigi; Ortel, Thomas L; Petri, Michelle; Rahman, Anisur; Roubey, Robert; Sciascia, Savino; Snyder, Melissa; Tebo, Anne E; Tincani, Angela; Willis, Rohan
2014-09-01
Current classification criteria for definite Antiphospholipid Syndrome (APS) require the use of three laboratory assays to detect antiphospholipid antibodies (aCL, anti-β2GPI and LA) in the presence of at least one of the two major clinical manifestations (i.e. thrombosis or pregnancy morbidity) of the syndrome. However, several other autoantibodies shown to be directed to other proteins or their complex with phospholipids have been proposed to be relevant to APS but their clinical utility and their diagnostic value remains elusive. This report summarizes the findings, conclusions and recommendations of the "APS Task Force 3-Laboratory Diagnostics and Trends" meeting that took place during the 14th International Congress on Antiphospholipid Antibodies (APLA 2013, September 18-21, Rio de Janeiro, RJ, Brazil). Copyright © 2014 Elsevier B.V. All rights reserved.
Rösner, Stephan; Gehlweiler, Kevin; Küsters, Uta; Kolbert, Mathias; Hübner, Kirsten; Pfennigwerth, Niels; Mack, Dietrich
2018-01-01
Multidrug-resistant Gram-negative bacilli (MDR-GNB) producing carbapenemases are increasing at an alarming speed. Rapid confirmation of carbapenemase type will be an important diagnostic step in clinical microbiology laboratories not only to reduce the risk of transmissions but also for optimising antibiotic therapy in the future. We compared diagnostic reliability of two commercially available molecular assays (Check-Direct CPE vs. AID line probe assay) for detection and typing of carbapenemase genes in 80 well-characterized isolates of MDR-GNB. Respective strains were isolated in various clinical specimens at our clinical microbiology laboratory. The reference standard included confirmation of carbapenemase-production at the molecular level at the German National Reference Laboratory for Multidrug-resistant Gram-negative bacteria (Ruhr-University Bochum, Germany). 53 Enterobacteriaceae and 27 members of the A. baumannii-complex were used in this study. The tested assays appeared highly reliable to confirm carbapenemase-producing Enterobacteriaceae (CPE) with respective sensitivities of 97.7%, but are currently unsuitable for analysis of members of the A. baumannii-complex. Both assays are easy to perform and rapid tools for confirmation and typing of the most common carbapenemase genes in Enterobacteriaceae. Implementation should be possible for any clinical microbiology laboratory with Check-Direct CPE being easier to handle and having less technological requirements.
Pankhurst, Louise J; del Ojo Elias, Carlos; Votintseva, Antonina A; Walker, Timothy M; Cole, Kevin; Davies, Jim; Fermont, Jilles M; Gascoyne-Binzi, Deborah M; Kohl, Thomas A; Kong, Clare; Lemaitre, Nadine; Niemann, Stefan; Paul, John; Rogers, Thomas R; Roycroft, Emma; Smith, E Grace; Supply, Philip; Tang, Patrick; Wilcox, Mark H; Wordsworth, Sarah; Wyllie, David; Xu, Li; Crook, Derrick W
2016-01-01
Summary Background Slow and cumbersome laboratory diagnostics for Mycobacterium tuberculosis complex (MTBC) risk delayed treatment and poor patient outcomes. Whole-genome sequencing (WGS) could potentially provide a rapid and comprehensive diagnostic solution. In this prospective study, we compare real-time WGS with routine MTBC diagnostic workflows. Methods We compared sequencing mycobacteria from all newly positive liquid cultures with routine laboratory diagnostic workflows across eight laboratories in Europe and North America for diagnostic accuracy, processing times, and cost between Sept 6, 2013, and April 14, 2014. We sequenced specimens once using local Illumina MiSeq platforms and processed data centrally using a semi-automated bioinformatics pipeline. We identified species or complex using gene presence or absence, predicted drug susceptibilities from resistance-conferring mutations identified from reference-mapped MTBC genomes, and calculated genetic distance to previously sequenced UK MTBC isolates to detect outbreaks. WGS data processing and analysis was done by staff masked to routine reference laboratory and clinical results. We also did a microcosting analysis to assess the financial viability of WGS-based diagnostics. Findings Compared with routine results, WGS predicted species with 93% (95% CI 90–96; 322 of 345 specimens; 356 mycobacteria specimens submitted) accuracy and drug susceptibility also with 93% (91–95; 628 of 672 specimens; 168 MTBC specimens identified) accuracy, with one sequencing attempt. WGS linked 15 (16% [95% CI 10–26]) of 91 UK patients to an outbreak. WGS diagnosed a case of multidrug-resistant tuberculosis before routine diagnosis was completed and discovered a new multidrug-resistant tuberculosis cluster. Full WGS diagnostics could be generated in a median of 9 days (IQR 6–10), a median of 21 days (IQR 14–32) faster than final reference laboratory reports were produced (median of 31 days [IQR 21–44]), at a cost of £481 per culture-positive specimen, whereas routine diagnosis costs £518, equating to a WGS-based diagnosis cost that is 7% cheaper annually than are present diagnostic workflows. Interpretation We have shown that WGS has a scalable, rapid turnaround, and is a financially feasible method for full MTBC diagnostics. Continued improvements to mycobacterial processing, bioinformatics, and analysis will improve the accuracy, speed, and scope of WGS-based diagnosis. Funding National Institute for Health Research, Department of Health, Wellcome Trust, British Colombia Centre for Disease Control Foundation for Population and Public Health, Department of Clinical Microbiology, Trinity College Dublin. PMID:26669893
Sawford, Kate; Vollman, Ardene Robinson; Stephen, Craig
2013-01-01
The animal and public health communities need to address the challenge posed by zoonotic emerging infectious diseases. To minimize the impacts of future events, animal disease surveillance will need to enable prompt event detection and response. Diagnostic laboratory-based surveillance systems targeting domestic animals depend in large part on private veterinarians to submit samples from cases to a laboratory. In contexts where pre-diagnostic laboratory surveillance systems have been implemented, this group of veterinarians is often asked to input data. This scenario holds true in Alberta where private cattle veterinarians have been asked to participate in the Alberta Veterinary Surveillance Network-Veterinary Practice Surveillance, a platform to which pre-diagnostic disease and non-disease case data are submitted. Consequently, understanding the factors that influence these veterinarians to submit cases to a laboratory and the complex of factors that affect their participation in surveillance programs is foundational to interpreting disease patterns reported by laboratories and engaging veterinarians in surveillance. A focused ethnographic study was conducted with ten cattle veterinarians in Alberta. Individual in-depth interviews with participants were recorded and transcribed to enable thematic analysis. Laboratory submissions were biased toward outbreaks of unknown cause, cases with unusual mortality rates, and issues with potential herd-level implications. Decreasing cattle value and government support for laboratory testing have contributed to fewer submissions over time. Participants were willing participants in surveillance, though government support and collaboration were necessary. Changes in the beef industry and veterinary profession, as well as cattle producers themselves, present both challenges and opportunities in surveillance. PMID:23741397
[Laboratory diagnostics of urogenital clamidiosis].
Churakov, A A; Kulichenko, A N; Kzakova, E S; Serebrianik, N E; Suvorov, A P; Kutyrev, V V; Glybochko, P V
2005-02-01
Laboratory diagnostic tools of urogenital clamidiosis--PCR, ELISA (IgG and IgM) and direct immunofluorescence (DIF)--were comparatively analyzed. The positive PCR result was checked by another PCR test with a different primer; 5 false positive responses were registered (specificity 99.6%). As against PCR, the sensitivity of ELISA made 53%, its specificity -75.5%, the diagnostic value of positive result -58%, the diagnostic value of negative result -71.6% and the diagnostics accuracy -66.7%. The respective DIF parameters were as follows: 36%, 90%, 81.5%, 54.2% and 60.9%. A high rate of detection (above 90%) of the conditionally pathogenic microflora associated with Chlamydia trachomatis (above 110 microbe cells/ml) was pointed out. Hardnerelli and ureaplasms were more often found in female smears, staphylococci and enterococci--in male sperm. It is underlined as important to hold complex examinations for Chlamidia (PCR, ELISA and DIC as an additional test) combined with bacteriological quantification of the conditionally pathogenic microflora and determination of its resistance to antibiotics.
Point of care investigations in pediatric care to improve health care in rural areas.
Walia, Kamini
2013-07-01
The good quality laboratory services in developing countries are often limited to major urban centers. As a result, many commercially available high-quality diagnostic tests for infectious diseases are neither accessible nor affordable to patients in the rural areas. Health facilities in rural areas are compromised and this limits the usability and performance of the best medical diagnostic technologies in rural areas as they are designed for air-conditioned laboratories, refrigerated storage of chemicals, a constant supply of calibrators and reagents, stable electrical power, highly trained personnel and rapid transportation of samples. The advent of new technologies have allowed miniaturization and integration of complex functions, which has made it possible for sophisticated diagnostic tools to move out of the developed-world laboratory in the form of a "point of care"(POC) tests. Many diagnostic tests are being developed using these platforms. However, the challenge is to develop diagnostics which are inexpensive, rugged and well suited to the medical and social contexts of the developing world and do not compromise on accuracy and reliability. The already available POC tests which are reliable and affordable, like for HIV infection, malaria, syphilis, and some neglected tropical diseases, and POC tests being developed for other diseases if correctly used and effectively regulated after rigorous evaluation, have the potential to make a difference in clinical management and improve surveillance. In order to use these tests effectively they would need to be supported by technically competent manpower, availability of good-quality reagents, and healthcare providers who value and are able to interpret laboratory results to guide treatment; and a system for timely communication between the laboratory and the healthcare provider. Strengthening the laboratories at the rural level can enable utilization of these diagnostics for improving the diagnosis and management of infectious diseases among children which require prompt treatment and thus, considerably reduce morbidity and mortality among the pediatric age group.
The main challenges that remain in applying high-throughput sequencing to clinical diagnostics.
Loeffelholz, Michael; Fofanov, Yuriy
2015-01-01
Over the last 10 years, the quality, price and availability of high-throughput sequencing instruments have improved to the point that this technology may be close to becoming a routine tool in the diagnostic microbiology laboratory. Two groups of challenges, however, have to be resolved in order to move this powerful research technology into routine use in the clinical microbiology laboratory. The computational/bioinformatics challenges include data storage cost and privacy concerns, requiring analysis to be performed without access to cloud storage or expensive computational infrastructure. The logistical challenges include interpretation of complex results and acceptance and understanding of the advantages and limitations of this technology by the medical community. This article focuses on the approaches to address these challenges, such as file formats, algorithms, data collection, reporting and good laboratory practices.
Laboratory Diagnosis of Tuberculosis in Resource-Poor Countries: Challenges and Opportunities
Parsons, Linda M.; Somoskövi, Ákos; Gutierrez, Cristina; Lee, Evan; Paramasivan, C. N.; Abimiku, Alash'le; Spector, Steven; Roscigno, Giorgio; Nkengasong, John
2011-01-01
Summary: With an estimated 9.4 million new cases globally, tuberculosis (TB) continues to be a major public health concern. Eighty percent of all cases worldwide occur in 22 high-burden, mainly resource-poor settings. This devastating impact of tuberculosis on vulnerable populations is also driven by its deadly synergy with HIV. Therefore, building capacity and enhancing universal access to rapid and accurate laboratory diagnostics are necessary to control TB and HIV-TB coinfections in resource-limited countries. The present review describes several new and established methods as well as the issues and challenges associated with implementing quality tuberculosis laboratory services in such countries. Recently, the WHO has endorsed some of these novel methods, and they have been made available at discounted prices for procurement by the public health sector of high-burden countries. In addition, international and national laboratory partners and donors are currently evaluating other new diagnostics that will allow further and more rapid testing in point-of-care settings. While some techniques are simple, others have complex requirements, and therefore, it is important to carefully determine how to link these new tests and incorporate them within a country's national diagnostic algorithm. Finally, the successful implementation of these methods is dependent on key partnerships in the international laboratory community and ensuring that adequate quality assurance programs are inherent in each country's laboratory network. PMID:21482728
Designing high speed diagnostics
NASA Astrophysics Data System (ADS)
Veliz Carrillo, Gerardo; Martinez, Adam; Mula, Swathi; Prestridge, Kathy; Extreme Fluids Team Team
2017-11-01
Timing and firing for shock-driven flows is complex because of jitter in the shock tube mechanical drivers. Consequently, experiments require dynamic triggering of diagnostics from pressure transducers. We explain the design process and criteria for setting up re-shock experiments at the Los Alamos Vertical Shock Tube facility, and the requirements for particle image velocimetry and planar laser induced fluorescence measurements necessary for calculating Richtmeyer-Meshkov variable density turbulent statistics. Dynamic triggering of diagnostics allows for further investigation of the development of the Richtemeyer-Meshkov instability at both initial shock and re-shock. Thanks to the Los Alamos National Laboratory for funding our project.
42 CFR 414.508 - Payment for a new clinical diagnostic laboratory test.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 3 2010-10-01 2010-10-01 false Payment for a new clinical diagnostic laboratory... SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.508 Payment for a new clinical diagnostic laboratory test. For a new clinical diagnostic laboratory test that is assigned a new or...
42 CFR 414.508 - Payment for a new clinical diagnostic laboratory test.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 3 2011-10-01 2011-10-01 false Payment for a new clinical diagnostic laboratory... SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.508 Payment for a new clinical diagnostic laboratory test. For a new clinical diagnostic laboratory test that is assigned a new or...
Project management: importance for diagnostic laboratories.
Croxatto, A; Greub, G
2017-07-01
The need for diagnostic laboratories to improve both quality and productivity alongside personnel shortages incite laboratory managers to constantly optimize laboratory workflows, organization, and technology. These continuous modifications of the laboratories should be conducted using efficient project and change management approaches to maximize the opportunities for successful completion of the project. This review aims at presenting a general overview of project management with an emphasis on selected critical aspects. Conventional project management tools and models, such as HERMES, described in the literature, associated personal experience, and educational courses on management have been used to illustrate this review. This review presents general guidelines of project management and highlights their importance for microbiology diagnostic laboratories. As an example, some critical aspects of project management will be illustrated with a project of automation, as experienced at the laboratories of bacteriology and hygiene of the University Hospital of Lausanne. It is important to define clearly beforehand the objective of a project, its perimeter, its costs, and its time frame including precise duration estimates of each step. Then, a project management plan including explanations and descriptions on how to manage, execute, and control the project is necessary to continuously monitor the progression of a project to achieve its defined goals. Moreover, a thorough risk analysis with contingency and mitigation measures should be performed at each phase of a project to minimize the impact of project failures. The increasing complexities of modern laboratories mean clinical microbiologists must use several management tools including project and change management to improve the outcome of major projects and activities. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Significance and integration of molecular diagnostics in the framework of veterinary practice.
Aranaz, Alicia
2015-01-01
The field of molecular diagnostics in veterinary practice is rapidly evolving. An array of molecular techniques of different complexity is available to facilitate the fast and specific diagnosis of animal diseases. The choice for the adequate technique is dependent on the mission and attributions of the laboratory and requires both a knowledge of the molecular biology basis and of its limitations. The ability to quickly detect pathogens and their characteristics would allow for precise decision-making and target measures such as prophylaxis, appropriate therapy, and biosafety plans to control disease outbreaks. In practice, taking benefit of the huge amount of data that can be obtained using molecular techniques highlights the need of collaboration between veterinarians in the laboratory and practitioners.
Bonar, Roslyn; Favaloro, Emmanuel; Zebeljan, Diane; Rosenfeld, David; Kershaw, Geoff; Mohammed, Soma; Marsden, Katherine; Hertzberg, Mark
2012-04-01
Laboratory identification of lupus anticoagulants (LA), an important component of the clinical diagnosis of the autoimmune disorder antiphospholipid syndrome (APS), is challenged by the heterogeneity of tests available, the diagnostic and laboratory approach undertaken, and the heterogeneity of the autoantibodies present. : To assess the laboratory approach for investigation of LA, as well as the utility of various tests and test approaches, given a difficult clinical scenario in which LA might or might not be present. Ninety-three participants in the Royal College of Pathologists of Australasia (RCPA) Haematology Quality Assurance Program (QAP) were sent 4 mL of a complex but strongly positive LA sample blinded to the nature of the abnormality. Seventy-three (79%) participants returned results and in most cases diagnostic interpretations. The laboratory approach to LA investigation of this sample was quite varied: 34.7% of participants concluded the sample was LA negative, with 91.7% of these performing dilute Russell viper venom time (dRVVT) testing without mixing, whereas 43.5% of participants identified a strong LA, with 96.7% of these having performed mixing studies. Most laboratories reporting negative LA instead identified the false presence of specific factor inhibitors against a variety of factors, including II, V and VIII. For this difficult challenge, performance of non-mixing dRVVT was associated with a high false negative LA rate. (C) 2012 Royal College of Pathologists of Australasia.
Senior Laboratory Animal Technician | Center for Cancer Research
PROGRAM DESCRIPTION The Laboratory Animal Sciences Program (LASP) provides exceptional quality animal care and technical support services for animal research performed at the National Cancer Institute at the Frederick National Laboratory for Cancer Research. LASP executes this mission by providing a broad spectrum of state-of-the-art technologies and services that are focused on the design, generation, characterization and application of genetically engineered and biological animal models of human disease, which are aimed at the development of targeted diagnostics and therapies. LASP contributes to advancing human health, developing new treatments, and improving existing treatments for cancer and other diseases while ensuring safe and humane treatment of animals. KEY ROLES/RESPONSIBILITIES The Senior Laboratory Animal Technician will be responsible for: Daily tasks associated with the care, breeding and treatment of research animals for experimental purposes Management of rodent breeding colonies consisting of multiple, genetically complex strains and associated record keeping and database management Colony management procedures including: tail clipping, animal identification, weaning Data entry consistent with complex colony management Collection of routine diagnostic samples Coordinating shipment of live animals and specimens Performing rodent experimental procedures including basic necropsy and blood collection Observation and recording of physical signs of animal health Knowledge of safe working practices using chemical carcinogen and biological hazards Work schedule may include weekend and holiday hours This position is in support of the Center for Cancer Research (CCR).
Evaluation of GenoType NTM-DR Assay for Identification of Mycobacterium chimaera.
Mok, Simone; Rogers, Thomas R; Fitzgibbon, Margaret
2017-06-01
Identification of species within the Mycobacterium avium complex (MAC) is difficult, and most current diagnostic laboratory tests cannot distinguish between species included in the complex. Differentiation of species within the MAC is important, as Mycobacterium chimaera has recently emerged as a major cause of invasive cardiovascular infections following open heart surgery. A new commercial diagnostic assay, GenoType NTM-DR ver. 1.0, is intended to differentiate between three species within the MAC, namely, Mycobacterium avium , Mycobacterium intracellulare , and Mycobacterium chimaera In this study, we investigated an archival collection of 173 MAC isolates using 16S rRNA and 16S-23S internal transcribed spacer (ITS) gene sequencing, and GenoType NTM-DR was evaluated for identifying M. chimaera and other species belonging to the MAC. Species identification of 157/173 (91%) isolates with the GenoType NTM-DR assay was in agreement with 16S rRNA and 16S-23S ITS gene sequencing results. Misidentification occurred with 16 isolates which belonged to four species included in the MAC that are rarely encountered in clinical specimens. Despite some limitations of this assay, GenoType NTM-DR had 100% specificity for identifying M. chimaera This novel assay will enable diagnostic laboratories to differentiate species belonging to the Mycobacterium avium complex and to accurately identify M. chimaera It can produce rapid results and is also more cost efficient than gene sequencing methods. Copyright © 2017 American Society for Microbiology.
USDA-ARS?s Scientific Manuscript database
Periodic monitoring of poultry flocks in the United States via molecular diagnostic methods has revealed a number of potential enteric viral pathogens in continuous circulation in turkeys and chickens. Recently, numerous enteric samples collected from turkey flocks in the southeastern United States ...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-05
... access to care, quality of care, health outcomes, and expenditures. DATES: Supporting information to... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare & Medicaid Services [CMS-5058-N... Tests Demonstration. The Demonstration is mandated by section 3113 of the Affordable Care Act. This...
Harper, Jason C.; Carson, Bryan D.; Bachand, George D.; ...
2015-07-14
Despite significant progress in development of bioanalytical devices cost, complexity, access to reagents and lack of infrastructure have prevented use of these technologies in resource-limited regions. To provide a sustainable tool in the global effort to combat infectious diseases the diagnostic device must be low cost, simple to operate and read, robust, and have sensitivity and specificity comparable to laboratory analysis. Thus, in this mini-review we describe recent work using laser machined plastic laminates to produce diagnostic devices that are capable of a wide variety of bioanalytical measurements and show great promise towards future use in low-resource environments.
Optical control and diagnostics sensors for gas turbine machinery
NASA Astrophysics Data System (ADS)
Trolinger, James D.; Jenkins, Thomas P.; Heeg, Bauke
2012-10-01
There exists a vast range of optical techniques that have been under development for solving complex measurement problems related to gas-turbine machinery and phenomena. For instance, several optical techniques are ideally suited for studying fundamental combustion phenomena in laboratory environments. Yet other techniques hold significant promise for use as either on-line gas turbine control sensors, or as health monitoring diagnostics sensors. In this paper, we briefly summarize these and discuss, in more detail, some of the latter class of techniques, including phosphor thermometry, hyperspectral imaging and low coherence interferometry, which are particularly suited for control and diagnostics sensing on hot section components with ceramic thermal barrier coatings (TBCs).
Tyrrell, Frances; Stafford, Cortney; Yakrus, Mitchell; Youngblood, Monica; Hill, Andrew; Johnston, Stephanie
We investigated data from US public health laboratories funded through the Centers for Disease Control and Prevention's Tuberculosis Elimination and Laboratory Cooperative Agreement to document trends and challenges in meeting national objectives in tuberculosis (TB) laboratory diagnoses. We examined data on workload and turnaround time from public health laboratories' progress reports during 2009-2013. We reviewed methodologies, laboratory roles, and progress toward rapid detection of Mycobacterium tuberculosis complex through nucleic acid amplification (NAA) testing. We compared selected data with TB surveillance reports to estimate public health laboratories' contribution to national diagnostic services. During the study period, culture and drug susceptibility tests decreased, but NAA testing increased. Public health laboratories achieved turnaround time benchmarks for drug susceptibility tests at lower levels than for acid-fast bacilli smear and identification from culture. NAA positivity in laboratories among surveillance-reported culture-positive TB cases increased from 26.6% (2355 of 8876) in 2009 to 40.0% (2948 of 7358) in 2013. Public health laboratories provided an estimated 50.9% (4285 of 8413 in 2010) to 57.2% (4210 of 7358 in 2013) of culture testing and 88.3% (6822 of 7727 in 2011) to 94.4% (6845 of 7250 in 2012) of drug susceptibility tests for all US TB cases. Public health laboratories contribute substantially to TB diagnoses in the United States. Although testing volumes mostly decreased, the increase in NAA testing indicates continued progress in rapid M tuberculosis complex detection.
Zanatta, Lucia; Valori, Laura; Cappelletto, Eleonora; Pozzebon, Maria Elena; Pavan, Elisabetta; Dei Tos, Angelo Paolo; Merkle, Dennis
2015-02-01
In the modern molecular diagnostic laboratory, cost considerations are of paramount importance. Automation of complex molecular assays not only allows a laboratory to accommodate higher test volumes and throughput but also has a considerable impact on the cost of testing from the perspective of reagent costs, as well as hands-on time for skilled laboratory personnel. The following study tracked the cost of labor (hands-on time) and reagents for fluorescence in situ hybridization (FISH) testing in a routine, high-volume pathology and cytogenetics laboratory in Treviso, Italy, over a 2-y period (2011-2013). The laboratory automated FISH testing with the VP 2000 Processor, a deparaffinization, pretreatment, and special staining instrument produced by Abbott Molecular, and compared hands-on time and reagent costs to manual FISH testing. The results indicated significant cost and time saving when automating FISH with VP 2000 when more than six FISH tests were run per week. At 12 FISH assays per week, an approximate total cost reduction of 55% was observed. When running 46 FISH specimens per week, the cost saving increased to 89% versus manual testing. The results demonstrate that the VP 2000 processor can significantly reduce the cost of FISH testing in diagnostic laboratories. © 2014 Society for Laboratory Automation and Screening.
Code of Federal Regulations, 2010 CFR
2010-10-01
... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical diagnostic laboratory test...
Code of Federal Regulations, 2011 CFR
2011-10-01
... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical diagnostic laboratory test...
Savel'eva, I V; Khatsukov, K X; Savel'eva, E I; Moskvitina, S I; Kovalev, D A; Savel'ev, V N; Kulichenko, A N; Antonenko, A D; Babenyshev, B V
2015-01-01
Improvement of laboratory diagnostics of cholera taking into the account appearance of hybrid variants of cholera vibrio El Tor biovar in the 1990s. Phenotypic and molecular-genetic properties of typical toxigenic (151 strains) and hybrid (102 strains) variants of El Tor biovar cholera vibrios, isolated in the Caucuses in 1970-1990 and 1993-1998, respectively, were studied. Toxigenicity gene DNA fragments, inherent to El Tor biovars or classic, were detected by using a reagent kit "Genes of Vibrio cholerae variant ctxB-rstR-rstC, REF" developed by us. Reagent kit "Genes of V. cholerae variant ctxB-rstR-rstC, REF" is proposed to be used for laboratory diagnostics of cholera during study of material from humans or environmental objects and for identification of V. cholerae 01 on genome level in PCR-analysis as a necessary addition to the classic scheme of bacteriological analysis. Laboratory diagnostics of cholera due to genetically altered (hybrid) variants of cholera vibrio El Tor biovar is based on a complex study of material from humans and environmental objects by routine bacteriologic and PCR-analysis methods with the aim of detection of gene DNA fragments in the studied material, that determine biovar (classic or El Tor), identification of V. cholerae O1 strains with differentiation of El Tor vibrios into typical and altered, as well as determination of enterotoxin, produced by the specific cholera vibrio strain (by the presence ctxB(El) or ctxB(Cl) gene DNA fragment, coding biosynthesis of CT-2 or CT-1, respectively).
Code of Federal Regulations, 2010 CFR
2010-10-01
... for a new clinical diagnostic laboratory test. 414.509 Section 414.509 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.509 Reconsideration of basis for and amount of payment for a new clinical diagnostic laboratory...
Miller, J Michael; Astles, Rex; Baszler, Timothy; Chapin, Kimberle; Carey, Roberta; Garcia, Lynne; Gray, Larry; Larone, Davise; Pentella, Michael; Pollock, Anne; Shapiro, Daniel S; Weirich, Elizabeth; Wiedbrauk, Danny
2012-01-06
Prevention of injuries and occupational infections in U.S. laboratories has been a concern for many years. CDC and the National Institutes of Health addressed the topic in their publication Biosafety in Microbiological and Biomedical Laboratories, now in its 5th edition (BMBL-5). BMBL-5, however, was not designed to address the day-to-day operations of diagnostic laboratories in human and animal medicine. In 2008, CDC convened a Blue Ribbon Panel of laboratory representatives from a variety of agencies, laboratory organizations, and facilities to review laboratory biosafety in diagnostic laboratories. The members of this panel recommended that biosafety guidelines be developed to address the unique operational needs of the diagnostic laboratory community and that they be science based and made available broadly. These guidelines promote a culture of safety and include recommendations that supplement BMBL-5 by addressing the unique needs of the diagnostic laboratory. They are not requirements but recommendations that represent current science and sound judgment that can foster a safe working environment for all laboratorians. Throughout these guidelines, quality laboratory science is reinforced by a common-sense approach to biosafety in day-to-day activities. Because many of the same diagnostic techniques are used in human and animal diagnostic laboratories, the text is presented with this in mind. All functions of the human and animal diagnostic laboratory--microbiology, chemistry, hematology, and pathology with autopsy and necropsy guidance--are addressed. A specific section for veterinary diagnostic laboratories addresses the veterinary issues not shared by other human laboratory departments. Recommendations for all laboratories include use of Class IIA2 biological safety cabinets that are inspected annually; frequent hand washing; use of appropriate disinfectants, including 1:10 dilutions of household bleach; dependence on risk assessments for many activities; development of written safety protocols that address the risks of chemicals in the laboratory; the need for negative airflow into the laboratory; areas of the laboratory in which use of gloves is optional or is recommended; and the national need for a central site for surveillance and nonpunitive reporting of laboratory incidents/exposures, injuries, and infections.
The Evolving Role of Companion Diagnostics for Breast Cancer in an Era of Next-Generation Omics.
Rosenbaum, Jason N; Weisman, Paul
2017-10-01
A companion diagnostic is a test for a specific biomarker-approved by the United States Food and Drug Administration-qualifying a patient to receive a specific, associated therapy. As interest has grown in precision medicine over the past decade, the principle of companion diagnostics has gained increasing purchase among laboratory professionals, clinicians, regulators, and even patients. The evolution of the biomarkers used to stratify and treat breast cancer illustrates the history of companion diagnostics and provides a lens through which to examine potential challenges. As new targeted therapies and corresponding biomarkers accumulate, algorithms for diagnosis and treatment necessarily become lengthier and more complex. To accommodate future needs of breast cancer patients, the companion diagnostic model will continue to adapt and evolve. Copyright © 2017 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
[The organization of scientific innovative laboratory complex of modern technologies].
Totskaia, E G; Rozhnova, O M; Mamonova, E V
2013-01-01
The article discusses the actual issues of scientific innovative activity during the realization of principles of private-public partnership. The experience of development of model of scientific innovative complex is presented The possibilities to implement research achievements and their application in the area of cell technologies, technologies of regenerative medicine, biochip technologies are demonstrated. The opportunities to provide high level of diagnostic and treatment in practical health care increase of accessibility and quality of medical care and population health promotion are discussed.
Biosafety principles and practices for the veterinary diagnostic laboratory.
Kozlovac, Joseph; Schmitt, Beverly
2015-01-01
Good biosafety and biocontainment programs and practices are critical components of the successful operation of any veterinary diagnostic laboratory. In this chapter we provide information and guidance on critical biosafety management program elements, facility requirements, protective equipment, and procedures necessary to ensure that the laboratory worker and the environment are adequately protected in the challenging work environment of the veterinary diagnostic laboratory in general and provide specific guidance for those laboratories employing molecular diagnostic techniques.
Anismus: the cause of constipation? Results of investigation and treatment.
Duthie, G S; Bartolo, D C
1992-01-01
Anismus, or failure of the somatic sphincter apparatus to relax at defecation, has been implicated as a major contributor to the problem of obstructed defecation. Current diagnostic methods depend on laboratory measurements of attempted defecation and the most complex, dynamic proctography has been the mainstay of diagnosis. Using a new computerized ambulatory method of recording sphincter function in these patients at home, we report an 80% reduction in our diagnostic rate suggesting that conventional tests fail to accurately diagnose this condition, probably because they poorly represent the natural physiology of defecation. Treatment of this distressing condition is more complex and a variety of surgical and pharmacological measures have failed. Biofeedback retraining of anorectal function of these patients has been very successful and represents the management of choice.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-04
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-82,379] Abbott Laboratories... February 22, 2013, applicable to workers of Abbott Laboratories, Diagnostic--Hematology division, including... Clara, California location of Abbott Laboratories, Diagnostic--Hematology Division. The Department has...
Coping with parvovirus infections in mice: health surveillance and control.
Janus, Lydia M; Bleich, Andre
2012-01-01
Parvoviruses of mice, minute virus of mice (MVM) and mouse parvovirus (MPV), are challenging pathogens to eradicate from laboratory animal facilities. Due to the impediment on rodent-based research, recent studies have focused on the assessment of re-derivation techniques and parvoviral potential to induce persistent infections. Summarizing recent data, this review gives an overview on studies associated with parvoviral impact on research, diagnostic methods, parvoviral persistence and re-derivation techniques, demonstrating the complex nature of parvovirus infection in mice and unfolding the challenge of controlling parvovirus infections in laboratory animal facilities.
Halligan, E; Edgeworth, J; Bisnauthsing, K; Bible, J; Cliff, P; Aarons, E; Klein, J; Patel, A; Goldenberg, S
2014-08-01
Laboratory diagnosis and clinical management of inpatients with diarrhoea is complex and time consuming. Tests are often requested sequentially and undertaken in different laboratories. This causes prolonged unnecessary presumptive isolation of patients, because most cases are non-infectious. A molecular multiplex test (Luminex(®) Gastrointestinal Pathogen Panel (GPP)) was compared with conventional testing over 8 months to determine diagnostic accuracy, turnaround times, laboratory costs, use of isolation facilities and user acceptability. A total of 262 (12%) patients had a pathogen detected by conventional methods compared with 483 (22.1%) by GPP. Most additional cases were detected in patients developing symptoms in the first 4 days of admission. Additional cases were detected because of presumed improved diagnostic sensitivity but also because clinicians had not requested the correct pathogen. Turnaround time (41.8 h) was faster than bacterial culture (66.5 h) and parasite investigation (66.5 h) but slower than conventional testing for Clostridium difficile (17.3 h) and viruses (27 h). The test could allow simplified requesting by clinicians and a consolidated laboratory workflow, reducing the overall number of specimens received by the laboratory. A total of 154 isolation days were saved at an estimated cost of £30 800. Consumables and labour were estimated at £150 641 compared with £63 431 for conventional testing. Multiplex molecular testing using a panel of targets allowed enhanced detection and a consolidated laboratory workflow. This is likely to be of greater benefit to cases that present within the first 4 days of hospital admission. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.
Biologics industry challenges for developing diagnostic tests for the National Veterinary Stockpile.
Hardham, J M; Lamichhane, C M
2013-01-01
Veterinary diagnostic products generated ~$3 billion US dollars in global sales in 2010. This industry is poised to undergo tremendous changes in the next decade as technological advances move diagnostic products from the traditional laboratory-based and handheld immunologic assays towards highly technical, point of care devices with increased sensitivity, specificity, and complexity. Despite these opportunities for advancing diagnostic products, the industry continues to face numerous challenges in developing diagnostic products for emerging and foreign animal diseases. Because of the need to deliver a return on the investment, research and development dollars continue to be focused on infectious diseases that have a negative impact on current domestic herd health, production systems, or companion animal health. Overcoming the administrative, legal, fiscal, and technological barriers to provide veterinary diagnostic products for the National Veterinary Stockpile will reduce the threat of natural or intentional spread of foreign diseases and increase the security of the food supply in the US.
Obstacles in the diagnostics and therapy of heparin-induced thrombocytopenia.
Antonijević, Nebojsa M; Radovanović, Nebojsa; Obradović, Slobodan; Vucelić, Dragica; Stojanović, Bojan; Miković, Danijela; Kovac, Mirjana; Kocica, Tina; Tadić, Svetlana; Antonijević, Irina; Drasković, Snezana; Djordjević, Valentina; Calija, Branko; Perunicić, Jovan; Vasiljević, Zorana
2010-01-01
An immune-mediated, severe, acquired prothrombotic disorder, heparin-induced thrombocytopenia type II (HIT II) occurs in 0.5-5% of patients exposed to unfractionated heparin longer than 5-7 days. Arterial and venous thromboses are induced by HIT II in about 35-50% of patients. Typical death rate for HIT is about 29%, while 21% of HIT patients result in amputation of a limb. The trend towards the occurrence of HIT due to the administration of low molecular weight heparins (LMWH) taking ever conspicuous place in the standard venous thromboembolism (VTE) prophylaxis has been more frequently observed recently. It is considered that LMWH may cause HIT II in about 0.25-1%. The need for further modification of HIPA assays with LMWH has been imposed in the HIT laboratory diagnostics, heretofore overburdened with complexity. There are several constantly opposing problems arising in HIT laboratory diagnostics, one of which is that in a certain number of patients immunologic assays detect nonpathogenic antibodies (mainly IgM or IgA heparin-PF4 antibodies) while, on the other hand, the occurrence of HIT pathogenetically mediated by minor antigens (neutrophil-activating peptide 2 or interleukin 8) may be neglected in certain cases. The following factors play an important role in the interpretation of each laboratory HIT assays performed: 1. correlation with HIT clinical probability test, the best known of which is 4T'score, 2. the interpretation of the laboratory findings dependent on the time of the thrombocytopenia onset, as well as 3. the sensitivity and specificity of each test respectively. The HIT diagnostics in the presence of other comorbid states which may also induce thrombocytopenia, more precisely known as pseudo HIT (cancer, sepsis, disseminated intravascular coagulation, pulmonary embolism, antiphospholipid syndrome, etc), represents a specific clinical problem.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-27
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-75,201] Abbott Laboratories..., applicable to workers of Abbott Laboratories, Diagnostics Division, including on-site leased workers from... (clerical) were employed on-site at the Irving, Texas location of Abbott Laboratories, Diagnostics Division...
Kuna, Andrea Tešija; Đerek, Lovorka; Kozmar, Ana; Drvar, Vedrana
2016-10-15
With the trend of increasing incidence of autoimmune diseases, laboratories are faced with exponential growth of the requests for tests relating the diagnosis of these diseases. Unfortunately, the lack of laboratory personnel experienced in this specific discipline of laboratory diagnostic, as well as an unawareness of a method limitation often results in confusion for clinicians. The aim was to gain insight into number and type of Croatian laboratories that perform humoral diagnostics with the final goal to improve and harmonize laboratory diagnostics of autoimmune diseases in Croatia. In order to get insight into current laboratory practice two questionnaires, consisting of 42 questions in total, were created. Surveys were conducted using SurveyMonkey application and were sent to 88 medical biochemistry laboratories in Croatia for the first survey. Out of 33 laboratories that declared to perform diagnostic from the scope, 19 were selected for the second survey based on the tests they pleaded to perform. The survey comprised questions regarding autoantibody hallmarks of systemic autoimmune diseases while regarding organ-specific autoimmune diseases was limited to diseases of liver, gastrointestinal and nervous system. Response rate was high with 80 / 88 (91%) laboratories which answered the first questionnaire, and 19 / 19 (1.0) for the second questionnaire. Obtained results of surveys indicate high heterogeneity in the performance of autoantibody testing among laboratories in Croatia. Results indicate the need of creating recommendations and algorithms in order to harmonize the approach to laboratory diagnostics of autoimmune diseases in Croatia.
Molecular Diagnostics of Fusion and Laboratory Plasmas
NASA Astrophysics Data System (ADS)
Fantz, U.
2005-05-01
The presence of molecules in the cold scrape-off layer of fusion experiments and industrial plasmas requires an understanding of the molecular dynamics in these low temperature plasmas. Suitable diagnostic methods can provide an insight in molecular processes in the plasma volume as well as for plasma surface interactions. A very simple but powerful technique is the molecular emission spectroscopy. Spectra are obtained easily, whereas interpretation might be very complex and relies on the availability of atomic and molecular data. Examples are given for hydrogen plasmas and plasmas with hydrocarbons which both are of importance in industrial applications as well as in fusion experiments.
The laboratory diagnosis of bacterial vaginosis
Money, Deborah
2005-01-01
Bacterial vaginosis (BV) is an extremely common health problem for women. In addition to the troublesome symptoms often associated with a disruption in the balance of vaginal flora, BV is associated with adverse gynecological and pregnancy outcomes. Although not technically a sexually transmitted infection, BV is a sexually associated condition. Diagnostic tests include real-time clinical/microbiological diagnosis, and the current gold standard, the standardized evaluation of morphotypes on Gram stain analysis. The inappropriate use of vaginal culture can be misleading. Future developments into molecular-based diagnostics will be important to further understand this complex endogenous flora disruption. PMID:18159532
Interpretation of diagnostic data: 5. How to do it with simple maths.
1983-11-01
The use of simple maths with the likelihood ratio strategy fits in nicely with our clinical views. By making the most out of the entire range of diagnostic test results (i.e., several levels, each with its own likelihood ratio, rather than a single cut-off point and a single ratio) and by permitting us to keep track of the likelihood that a patient has the target disorder at each point along the diagnostic sequence, this strategy allows us to place patients at an extremely high or an extremely low likelihood of disease. Thus, the numbers of patients with ultimately false-positive results (who suffer the slings of labelling and the arrows of needless therapy) and of those with ultimately false-negative results (who therefore miss their chance for diagnosis and, possibly, efficacious therapy) will be dramatically reduced. The following guidelines will be useful in interpreting signs, symptoms and laboratory tests with the likelihood ratio strategy: Seek out, and demand from the clinical or laboratory experts who ought to know, the likelihood ratios for key symptoms and signs, and several levels (rather than just the positive and negative results) of diagnostic test results. Identify, when feasible, the logical sequence of diagnostic tests. Estimate the pretest probability of disease for the patient, and, using either the nomogram or the conversion formulas, apply the likelihood ratio that corresponds to the first diagnostic test result. While remembering that the resulting post-test probability or odds from the first test becomes the pretest probability or odds for the next diagnostic test, repeat the process for all the pertinent symptoms, signs and laboratory studies that pertain to the target disorder. However, these combinations may not be independent, and convergent diagnostic tests, if treated as independent, will combine to overestimate the final post-test probability of disease. You are now far more sophisticated in interpreting diagnostic tests than most of your teachers. In the last part of our series we will show you some rather complex strategies that combine diagnosis and therapy, quantify our as yet nonquantified ideas about use, and require the use of at least a hand calculator.
Interpretation of diagnostic data: 5. How to do it with simple maths.
1983-01-01
The use of simple maths with the likelihood ratio strategy fits in nicely with our clinical views. By making the most out of the entire range of diagnostic test results (i.e., several levels, each with its own likelihood ratio, rather than a single cut-off point and a single ratio) and by permitting us to keep track of the likelihood that a patient has the target disorder at each point along the diagnostic sequence, this strategy allows us to place patients at an extremely high or an extremely low likelihood of disease. Thus, the numbers of patients with ultimately false-positive results (who suffer the slings of labelling and the arrows of needless therapy) and of those with ultimately false-negative results (who therefore miss their chance for diagnosis and, possibly, efficacious therapy) will be dramatically reduced. The following guidelines will be useful in interpreting signs, symptoms and laboratory tests with the likelihood ratio strategy: Seek out, and demand from the clinical or laboratory experts who ought to know, the likelihood ratios for key symptoms and signs, and several levels (rather than just the positive and negative results) of diagnostic test results. Identify, when feasible, the logical sequence of diagnostic tests. Estimate the pretest probability of disease for the patient, and, using either the nomogram or the conversion formulas, apply the likelihood ratio that corresponds to the first diagnostic test result. While remembering that the resulting post-test probability or odds from the first test becomes the pretest probability or odds for the next diagnostic test, repeat the process for all the pertinent symptoms, signs and laboratory studies that pertain to the target disorder. However, these combinations may not be independent, and convergent diagnostic tests, if treated as independent, will combine to overestimate the final post-test probability of disease. You are now far more sophisticated in interpreting diagnostic tests than most of your teachers. In the last part of our series we will show you some rather complex strategies that combine diagnosis and therapy, quantify our as yet nonquantified ideas about use, and require the use of at least a hand calculator. PMID:6671182
Tazawa, Yoshiaki
2016-01-01
On July 1st, 2013, the Ministry of Health, Labor and Welfare (MHLW) issued an official notification regarding the co-development of companion diagnostics (CDx) with a drug which requires any exclusive diagnostic test or medical device to predict efficacy or adverse reactions to the drug. The main frame and contents in the MHLW's notification are quite similar to the summaries in the final guidance issued by the US Food and Drug Administration (FDA) on August 6th, 2014 Guidance for Industry and Food and Drug Administration Staff (In Vitro Companion Diagnostic Devices, [2014] ), and these recommend industries to develop, study and submit CDx and the corresponding drug contemporaneously as much as possible. Following the MHLW's notification, the Pharmaceutical and Medical Device Agency (PMDA) notified on December 26th, 2013, "the technical guidance for co-development of CDx and the drug" that mentioned the regulatory requirements for clinical trial of the drug and CDx as well as analytical validity of CDx required for the trials. These official notifications from the Ministry and the Agency may be useful for pharmaceutical and diagnostics makers to understand how they should co-develop and validate CDx for clinical trials and regulatory submission. However, since the most anticipated technologies such as the next generation sequencer (NGS) are more complex and its medical risks could be high level, the existing regulatory system focusing on only diagnostics reagents and devices that are developed and manufactured by in vitro diagnostics (IVD) makers may be no longer suitable for the characteristics of CDx for the future.As an increase of clinical needs for multiple biomarkers assay by DNA sequencer, on November 19th, 2013, the FDA cleared 510 K for NGS and its universal kit. On October 3rd, 2014, moreover, the agency notified two drafts of guidance (Anticipated Details of the Draft Guidance for Industry, Food and Drug Administration Staff, and Clinical Laboratory in Framework for Regulatory Oversight of Laboratory Developed Tests (LDTs), [2014]; Anticipated Details of the Draft Guidance for Industry, Food and Drug Administration Staff, and Clinical Laboratory in FDA Notification and Medical Device Reporting for Laboratory Developed Tests (LDT), [2014]) for oversight of laboratory developed tests (LDTs) with medium or high medical risks. These FDA's strategic decisions and new regulatory frameworks may allow the clinical laboratories to develop and perform more easily NGS-based CDx under the certification of Clinical Laboratory Improvement Amendments (CLIA). However, neither law nor regulated quality management system similar to the CLIA exists in Japan. To effectively validate LDTs and NGS for medical practice, Japan should learn more the current regulatory changes and initiatives in the US, as well as to reform the regulatory frameworks and create any regulated quality management system for clinical laboratory testing to be reimbursed.
A Model-based Health Monitoring and Diagnostic System for the UH-60 Helicopter. Appendix D
NASA Technical Reports Server (NTRS)
Patterson-Hine, Ann; Hindson, William; Sanderfer, Dwight; Deb, Somnath; Domagala, Chuck
2001-01-01
Model-based reasoning techniques hold much promise in providing comprehensive monitoring and diagnostics capabilities for complex systems. We are exploring the use of one of these techniques, which utilizes multi-signal modeling and the TEAMS-RT real-time diagnostic engine, on the UH-60 Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) flight research aircraft. We focus on the engine and transmission systems, and acquire sensor data across the 1553 bus as well as by direct analog-to-digital conversion from sensors to the QHuMS (Qualtech health and usage monitoring system) computer. The QHuMS computer uses commercially available components and is rack-mounted in the RASCAL facility. A multi-signal model of the transmission and engine subsystems enables studies of system testability and analysis of the degree of fault isolation available with various instrumentation suites. The model and examples of these analyses will be described and the data architectures enumerated. Flight tests of this system will validate the data architecture and provide real-time flight profiles to be further analyzed in the laboratory.
Nikolaev, N S; Nazarova, V V; Dobrovol'skaia, N Iu; Orlova, A V; Pchelova, N N
2014-10-01
The article presents experience of clinical diagnostic laboratory of the Federal Center of traumatology, orthopedics and endoprosthesis replacement of Minzdrav of Russia (Cheboksary) in the area of quality management of medical laboratory services on the basis of evaluation of efficacy and effectiveness of processes. The factors effecting quality of functioning of clinical diagnostic laboratory are indicated. The criteria and indicators of efficacy of work of employees of clinical diagnostic laboratory are presented.
ERIC Educational Resources Information Center
Seaton, Vaughn A.
1980-01-01
The veterinary diagnostic laboratory's prime role has been diagnosis and/or laboratory findings to assist a diagnosis. Interpretation and evaluation and more involvement with decision-making in monitoring groups of animals and their health status are seen as future roles for diagnostic laboratories. (MLW)
Taylor, Sara; Bennett, Katie M; Deignan, Joshua L; Hendrix, Ericka C; Orton, Susan M; Verma, Shalini; Schutzbank, Ted E
2014-05-01
Molecular diagnostics is a rapidly growing specialty in the clinical laboratory assessment of pathology. Educational programs in medical laboratory science and specialized programs in molecular diagnostics must address the training of clinical scientists in molecular diagnostics, but the educational curriculum for this field is not well defined. Moreover, our understanding of underlying genetic contributions to specific diseases and the technologies used in molecular diagnostics laboratories change rapidly, challenging providers of training programs in molecular diagnostics to keep their curriculum current and relevant. In this article, we provide curriculum recommendations to molecular diagnostics training providers at both the baccalaureate and master's level of education. We base our recommendations on several factors. First, we considered National Accrediting Agency for Clinical Laboratory Sciences guidelines for accreditation of molecular diagnostics programs, because educational programs in clinical laboratory science should obtain its accreditation. Second, the guidelines of several of the best known certifying agencies for clinical laboratory scientists were incorporated into our recommendations. Finally, we relied on feedback from current employers of molecular diagnostics scientists, regarding the skills and knowledge that they believe are essential for clinical scientists who will be performing molecular testing in their laboratories. We have compiled these data into recommendations for a molecular diagnostics curriculum at both the baccalaureate and master's level of education. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...
Kuna, Andrea Tešija; Đerek, Lovorka; Kozmar, Ana; Drvar, Vedrana
2016-01-01
Introduction With the trend of increasing incidence of autoimmune diseases, laboratories are faced with exponential growth of the requests for tests relating the diagnosis of these diseases. Unfortunately, the lack of laboratory personnel experienced in this specific discipline of laboratory diagnostic, as well as an unawareness of a method limitation often results in confusion for clinicians. The aim was to gain insight into number and type of Croatian laboratories that perform humoral diagnostics with the final goal to improve and harmonize laboratory diagnostics of autoimmune diseases in Croatia. Materials and methods In order to get insight into current laboratory practice two questionnaires, consisting of 42 questions in total, were created. Surveys were conducted using SurveyMonkey application and were sent to 88 medical biochemistry laboratories in Croatia for the first survey. Out of 33 laboratories that declared to perform diagnostic from the scope, 19 were selected for the second survey based on the tests they pleaded to perform. The survey comprised questions regarding autoantibody hallmarks of systemic autoimmune diseases while regarding organ-specific autoimmune diseases was limited to diseases of liver, gastrointestinal and nervous system. Results Response rate was high with 80 / 88 (91%) laboratories which answered the first questionnaire, and 19 / 19 (1.0) for the second questionnaire. Obtained results of surveys indicate high heterogeneity in the performance of autoantibody testing among laboratories in Croatia. Conclusions Results indicate the need of creating recommendations and algorithms in order to harmonize the approach to laboratory diagnostics of autoimmune diseases in Croatia. PMID:27812306
Chen, J H K; She, K K K; Kwong, T-C; Wong, O-Y; Siu, G K H; Leung, C-C; Chang, K-C; Tam, C-M; Ho, P-L; Cheng, V C C; Yuen, K-Y; Yam, W-C
2015-09-01
The automated high-throughput Abbott RealTime MTB real-time PCR assay has been recently launched for Mycobacterium tuberculosis complex (MTBC) clinical diagnosis. This study would like to evaluate its performance. We first compared its diagnostic performance with the Roche Cobas TaqMan MTB assay on 214 clinical respiratory specimens. Prospective analysis of a total 520 specimens was then performed to further evaluate the Abbott assay. The Abbott assay showed a lower limit of detection at 22.5 AFB/ml, which was more sensitive than the Cobas assay (167.5 AFB/ml). The two assays demonstrated a significant difference in diagnostic performance (McNemar's test; P = 0.0034), in which the Abbott assay presented significantly higher area under curve (AUC) than the Cobas assay (1.000 vs 0.880; P = 0.0002). The Abbott assay demonstrated extremely low PCR inhibition on clinical respiratory specimens. The automated Abbott assay required only very short manual handling time (0.5 h), which could help to improve the laboratory management. In the prospective analysis, the overall estimates for sensitivity and specificity of the Abbott assay were both 100 % among smear-positive specimens, whereas the smear-negative specimens were 96.7 and 96.1 %, respectively. No cross-reactivity with non-tuberculosis mycobacterial species was observed. The superiority in sensitivity of the Abbott assay for detecting MTBC in smear-negative specimens could further minimize the risk in MTBC false-negative detection. The new Abbott RealTime MTB assay has good diagnostic performance which can be a useful diagnostic tool for rapid MTBC detection in clinical laboratories.
Zhang, Michael Y.; Keel, Siobán B.; Walsh, Tom; Lee, Ming K.; Gulsuner, Suleyman; Watts, Amanda C.; Pritchard, Colin C.; Salipante, Stephen J.; Jeng, Michael R.; Hofmann, Inga; Williams, David A.; Fleming, Mark D.; Abkowitz, Janis L.; King, Mary-Claire; Shimamura, Akiko
2015-01-01
Accurate and timely diagnosis of inherited bone marrow failure and inherited myelodysplastic syndromes is essential to guide clinical management. Distinguishing inherited from acquired bone marrow failure/myelodysplastic syndrome poses a significant clinical challenge. At present, diagnostic genetic testing for inherited bone marrow failure/myelodysplastic syndrome is performed gene-by-gene, guided by clinical and laboratory evaluation. We hypothesized that standard clinically-directed genetic testing misses patients with cryptic or atypical presentations of inherited bone marrow failure/myelodysplastic syndrome. In order to screen simultaneously for mutations of all classes in bone marrow failure/myelodysplastic syndrome genes, we developed and validated a panel of 85 genes for targeted capture and multiplexed massively parallel sequencing. In patients with clinical diagnoses of Fanconi anemia, genomic analysis resolved subtype assignment, including those of patients with inconclusive complementation test results. Eight out of 71 patients with idiopathic bone marrow failure or myelodysplastic syndrome were found to harbor damaging germline mutations in GATA2, RUNX1, DKC1, or LIG4. All 8 of these patients lacked classical clinical stigmata or laboratory findings of these syndromes and only 4 had a family history suggestive of inherited disease. These results reflect the extensive genetic heterogeneity and phenotypic complexity of bone marrow failure/myelodysplastic syndrome phenotypes. This study supports the integration of broad unbiased genetic screening into the diagnostic workup of children and young adults with bone marrow failure and myelodysplastic syndromes. PMID:25239263
Current insights into the laboratory diagnosis of HIT.
Bakchoul, T; Zöllner, H; Greinacher, A
2014-06-01
Heparin-induced thrombocytopenia (HIT) is an adverse drug reaction and prothrombotic disorder caused by immunization against platelet factor 4 (PF4) after complex formation with heparin or other polyanions. After antibody binding to PF4/heparin complexes, HIT antibodies are capable of intravascular platelet activation by cross-linking Fc gamma receptor IIa (FcγRIIa) on the platelet surface leading to a platelet count decrease and/or thrombosis. In contrast to most other immune-mediated disorders, the currently available laboratory tests for anti-PF4/heparin antibodies show a high sensitivity also for clinically irrelevant antibodies. This makes the diagnosis of HIT challenging and bears the risk to substantially overdiagnose HIT. The strength of the antigen assays for HIT is in ruling out HIT when the test is negative. Functional assays have a higher specificity for clinically relevant antibodies, but they are restricted to specialized laboratories. Currently, a Bayesian approach combining the clinical likelihood estimation for HIT with laboratory tests is the most appropriate approach to diagnose HIT. In this review, we give an overview on currently available diagnostic procedures and discuss their limitations. © 2014 John Wiley & Sons Ltd.
Monitoring and investigating natural disease by veterinary pathologists in diagnostic laboratories.
O'Toole, D
2010-01-01
Many emerging diseases in animals are initially recognized by diagnostic pathologists in animal health laboratories using routine laboratory submissions, in conjunction with clinical veterinarians and wildlife biologists. Familiar recent examples are chronic wasting disease, bovine spongiform encephalopathy, West Nile encephalomyelitis in North America, and postweaning multisystemic wasting syndrome in pigs. The recognition of new diseases in animals requires that the curiosity of diagnosticians be articulated with the capacity of animal health laboratories to create effective diagnostic teams, solicit additional cases from the field at minimal cost to clients, and develop relationships with basic researchers. Bovine neosporosis is used as an example to illustrate how a disease investigation triggered by routine clinical accessions can have international ramifications. Between the late 1980s and 1995, diagnosticians with California's animal health laboratory system identified neosporosis as a cause of reproductive wastage in cattle, characterized the lesions, isolated the agent, defined routes of transmission, met Koch's postulates, and developed diagnostic assays. Diagnostic pathologists catalyzed the process. The neosporosis investigation in California suggests useful attributes of veterinary diagnostic laboratories that pursue emerging diseases identified through routine laboratory accessions.
76 FR 61153 - Robert Raymond Reppy, D.O.; Decision and Order
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-03
... diagnostic and laboratory tests consistent with good medical care,'' ``[f]ormulate[] a therapeutic plan... examination and appropriate diagnostic and laboratory testing.'' Id. In May 2000, the Louisiana State Board of..., examination, physical examination and appropriate diagnostic and laboratory testing; Discussing with the...
The Development of a Post-Baccalaureate Certificate Program in Molecular Diagnostics
Williams, Gail S.; Brown, Judith D.; Keagle, Martha B.
2000-01-01
A post-baccalaureate certificate program in diagnostic molecular sciences was created in 1995 by the Diagnostic Genetic Sciences Program in the School of Allied Health at the University of Connecticut. The required on-campus lecture and laboratory courses include basic laboratory techniques, health care issues, cell biology, immunology, human genetics, research, management, and molecular diagnostic techniques and laboratory in molecular diagnostics. These courses precede a 6-month, full-time practicum at an affiliated full-service molecular laboratory. The practicum includes amplification and blotting methods, a research project, and a choice of specialized electives including DNA sequencing, mutagenesis, in situ hybridization methods, or molecular diagnostic applications in microbiology. Graduates of the program are immediately eligible to sit for the National Credentialing Agency examination in molecular biology to obtain the credential Clinical Laboratory Specialist in Molecular Biology (CLSp(MB). This description of the University of Connecticut program may assist other laboratory science programs in creating similar curricula. PMID:11232107
Code of Federal Regulations, 2013 CFR
2013-10-01
... in the 80000 series of the Current Procedural Terminology published by the American Medical... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...
Interpretation of diagnostic data: 6. How to do it with more complex maths.
1983-11-15
We have now shown you how to use decision analysis in making those rare, tough diagnostic decisions that are not soluble through other, easier routes. In summary, to "use more complex maths" the following steps will be useful: Create a decision tree or map of all the pertinent courses of action and their consequences. Assign probabilities to the branches of each chance node. Assign utilities to each of the potential outcomes shown on the decision tree. Combine the probabilities and utilities for each node on the decision tree. Pick the decision that leads to the highest expected utility. Test your decision for its sensitivity to clinically sensible changes in probabilities and utilities. That concludes this series of clinical epidemiology rounds. You've come a long way from "doing it with pictures" and are now able to extract most of the diagnostic information that can be provided from signs, symptoms and laboratory investigations. We would appreciate learning whether you have found this series useful and how we can do a better job of presenting these and other elements of "the science of the art of medicine".
Chin, Ephrem L H; da Silva, Cristina; Hegde, Madhuri
2013-02-19
Detecting mutations in disease genes by full gene sequence analysis is common in clinical diagnostic laboratories. Sanger dideoxy terminator sequencing allows for rapid development and implementation of sequencing assays in the clinical laboratory, but it has limited throughput, and due to cost constraints, only allows analysis of one or at most a few genes in a patient. Next-generation sequencing (NGS), on the other hand, has evolved rapidly, although to date it has mainly been used for large-scale genome sequencing projects and is beginning to be used in the clinical diagnostic testing. One advantage of NGS is that many genes can be analyzed easily at the same time, allowing for mutation detection when there are many possible causative genes for a specific phenotype. In addition, regions of a gene typically not tested for mutations, like deep intronic and promoter mutations, can also be detected. Here we use 20 previously characterized Sanger-sequenced positive controls in disease-causing genes to demonstrate the utility of NGS in a clinical setting using standard PCR based amplification to assess the analytical sensitivity and specificity of the technology for detecting all previously characterized changes (mutations and benign SNPs). The positive controls chosen for validation range from simple substitution mutations to complex deletion and insertion mutations occurring in autosomal dominant and recessive disorders. The NGS data was 100% concordant with the Sanger sequencing data identifying all 119 previously identified changes in the 20 samples. We have demonstrated that NGS technology is ready to be deployed in clinical laboratories. However, NGS and associated technologies are evolving, and clinical laboratories will need to invest significantly in staff and infrastructure to build the necessary foundation for success.
Gray, J W; Milner, P J; Edwards, E H; Daniels, J P; Khan, K S
2012-07-01
Point-of-care testing (POCT) is one of the fastest growing sectors of laboratory diagnostics. Most tests in routine use are haematology or biochemistry tests that are of low complexity. Microbiology POCT has been constrained by a lack of tests that are both accurate and of low complexity. We describe our experience of the practical issues around using more complex POCT for detection of Group B streptococci (GBS) in swabs from labouring women. We evaluated two tests for their feasibility in POCT: an optical immune assay (Biostar OIA Strep B, Inverness Medical, Princetown, NJ) and a PCR (IDI-Strep B, Cepheid, Sunnyvale, CA), which have been categorised as being of moderate and high complexity, respectively. A total of 12 unqualified midwifery assistants (MA) were trained to undertake testing on the delivery suite. A systematic approach to the introduction and management of POC testing was used. Modelling showed that the probability of test results being available within a clinically useful timescale was high. However, in the clinical setting, we found it impossible to maintain reliable availability of trained testers. Implementation of more complex POC testing is technically feasible, but it is expensive, and may be difficult to achieve in a busy delivery suite.
Antimicrobial susceptibility testing by Australian veterinary diagnostic laboratories.
Hardefeldt, L Y; Marenda, M; Crabb, H; Stevenson, M A; Gilkerson, J R; Billman-Jacobe, H; Browning, G F
2018-04-01
The national strategy for tackling antimicrobial resistance highlights the need for antimicrobial stewardship in veterinary practice and for surveillance of antimicrobial susceptibility in veterinary pathogens. Diagnostic laboratories have an important role in facilitating both of these processes, but it is unclear whether data from veterinary diagnostic laboratories are similar enough to allow for compilation and if there is consistent promotion of appropriate antimicrobial use embedded in the approaches of different laboratories to susceptibility testing. A cross-sectional study of antimicrobial susceptibility testing and reporting procedures by Australian veterinary diagnostic laboratories was conducted in 2017 using an online questionnaire. All 18 veterinary diagnostic laboratories in Australia completed the questionnaire. Kirby-Bauer disc diffusion was the method predominantly used for antimicrobial susceptibility testing and was used to evaluate 86% of all isolates, although two different protocols were used across the 18 laboratories (CLSI 15/18, CDS 3/18). Minimum inhibitory concentrations were never reported by 61% of laboratories. Common isolates were consistently reported on across all species, except for gram-negative isolates in pigs, for which there was some variation in the approach to reporting. There was considerable diversity in the panels of antimicrobials used for susceptibility testing on common isolates and no consistency was apparent between laboratories for any bacterial species. We recommend that nationally agreed and consistent antimicrobial panels for routine susceptibility testing should be developed and a uniform set of guidelines should be adopted by veterinary diagnostic laboratories in Australia. © 2018 Australian Veterinary Association.
van Dorp, Sofie M; Notermans, Daan W; Alblas, Jeroen; Gastmeier, Petra; Mentula, Silja; Nagy, Elisabeth; Spigaglia, Patrizia; Ivanova, Katiusha; Fitzpatrick, Fidelma; Barbut, Frédéric; Morris, Trefor; Wilcox, Mark H; Kinross, Pete; Suetens, Carl; Kuijper, Ed J
2016-07-21
Suboptimal laboratory diagnostics for Clostridium difficile infection (CDI) impedes its surveillance and control across Europe. We evaluated changes in local laboratory CDI diagnostics and changes in national diagnostic and typing capacity for CDI during the European C. difficile Infection Surveillance Network (ECDIS-Net) project, through cross-sectional surveys in 33 European countries in 2011 and 2014. In 2011, 126 (61%) of a convenience sample of 206 laboratories in 31 countries completed a survey on local diagnostics. In 2014, 84 (67%) of these 126 laboratories in 26 countries completed a follow-up survey. Among laboratories that participated in both surveys, use of CDI diagnostics deemed 'optimal' or 'acceptable' increased from 19% to 46% and from 10% to 15%, respectively (p < 0.001). The survey of national capacity was completed by national coordinators of 31 and 32 countries in 2011 and 2014, respectively. Capacity for any C. difficile typing method increased from 22/31 countries in 2011 to 26/32 countries in 2014; for PCR ribotyping from 20/31 countries to 23/32 countries, and specifically for capillary PCR ribotyping from 7/31 countries to 16/32 countries. While our study indicates improved diagnostic capability and national capacity for capillary PCR ribotyping across European laboratories between 2011 and 2014, increased use of 'optimal' diagnostics should be promoted. This article is copyright of The Authors, 2016.
Zenina, L P; Godkov, M A
2013-08-01
The article presents the experience of implementation of system of quality management into the practice of multi-field laboratory of emergency medical care hospital. The analysis of laboratory errors is applied and the modes of their prevention are demonstrated. The ratings of department of laboratory diagnostic of the N. V. Sklifosofskiy research institute of emergency care in the program EQAS (USA) Monthly Clinical Chemistry from 2007 are presented. The implementation of the system of quality management of laboratory analysis into department of laboratory diagnostic made it possible to support physicians of clinical departments with reliable information. The confidence of clinicians to received results increased. The effectiveness of laboratory diagnostic increased due to lowering costs of analysis without negative impact to quality of curative process.
Jacobsen, Sonja; Patel, Pranav; Schmidt-Chanasit, Jonas; Leparc-Goffart, Isabelle; Teichmann, Anette; Zeller, Herve; Niedrig, Matthias
2016-03-01
Since the re-emergence of Chikungunya virus (CHIKV) in Reunion in 2005 and the recent outbreak in the Caribbean islands with an expansion to the Americas the CHIK diagnostic became very important. We evaluate the performance of laboratories regarding molecular and serological diagnostic of CHIK worldwide. A panel of 12 samples for molecular and 13 samples for serology were provided to 60 laboratories in 40 countries for evaluating the sensitivity and specificity of molecular and serology testing. The panel for molecular diagnostic testing was analysed by 56 laboratories returning 60 data sets of results whereas the 56 and 60 data sets were returned for IgG and IgM diagnostic from the participating laboratories. Twenty-three from 60 data sets performed optimal, 7 acceptable and 30 sets of results require improvement. From 50 data sets only one laboratory shows an optimal performance for IgM detection, followed by 9 data sets with acceptable and the rest need for improvement. From 46 IgG serology data sets 20 provide an optimal, 2 an acceptable and 24 require improvement performance. The evaluation of some of the diagnostic performances allows linking the quality of results to the in-house methods or commercial assays used. The external quality assurance for CHIK diagnostics provides a good overview on the laboratory performance regarding sensitivity and specificity for the molecular and serology diagnostic required for the quick and reliable analysis of suspected CHIK patients. Nearly half of the laboratories have to improve their diagnostic profile to achieve a better performance. Copyright © 2016 Z. Published by Elsevier B.V. All rights reserved.
Lee, Roy E; Henricks, Walter H; Sirintrapun, Sahussapont J
2016-03-01
Molecular diagnostic testing presents new challenges to information management that are yet to be sufficiently addressed by currently available information systems for the molecular laboratory. These challenges relate to unique aspects of molecular genetic testing: molecular test ordering, informed consent issues, diverse specimen types that encompass the full breadth of specimens handled by traditional anatomic and clinical pathology information systems, data structures and data elements specific to molecular testing, varied testing workflows and protocols, diverse instrument outputs, unique needs and requirements of molecular test reporting, and nuances related to the dissemination of molecular pathology test reports. By satisfactorily addressing these needs in molecular test data management, a laboratory information system designed for the unique needs of molecular diagnostics presents a compelling reason to migrate away from the current paper and spreadsheet information management that many molecular laboratories currently use. This paper reviews the issues and challenges of information management in the molecular diagnostics laboratory.
Benchmarking in pathology: development of an activity-based costing model.
Burnett, Leslie; Wilson, Roger; Pfeffer, Sally; Lowry, John
2012-12-01
Benchmarking in Pathology (BiP) allows pathology laboratories to determine the unit cost of all laboratory tests and procedures, and also provides organisational productivity indices allowing comparisons of performance with other BiP participants. We describe 14 years of progressive enhancement to a BiP program, including the implementation of 'avoidable costs' as the accounting basis for allocation of costs rather than previous approaches using 'total costs'. A hierarchical tree-structured activity-based costing model distributes 'avoidable costs' attributable to the pathology activities component of a pathology laboratory operation. The hierarchical tree model permits costs to be allocated across multiple laboratory sites and organisational structures. This has enabled benchmarking on a number of levels, including test profiles and non-testing related workload activities. The development of methods for dealing with variable cost inputs, allocation of indirect costs using imputation techniques, panels of tests, and blood-bank record keeping, have been successfully integrated into the costing model. A variety of laboratory management reports are produced, including the 'cost per test' of each pathology 'test' output. Benchmarking comparisons may be undertaken at any and all of the 'cost per test' and 'cost per Benchmarking Complexity Unit' level, 'discipline/department' (sub-specialty) level, or overall laboratory/site and organisational levels. We have completed development of a national BiP program. An activity-based costing methodology based on avoidable costs overcomes many problems of previous benchmarking studies based on total costs. The use of benchmarking complexity adjustment permits correction for varying test-mix and diagnostic complexity between laboratories. Use of iterative communication strategies with program participants can overcome many obstacles and lead to innovations.
The capacity of diagnostic laboratories in Kenya for detecting infectious diseases.
Slotved, H-C; Yatich, Kennedy K; Sam, Shem Otoi; Ndhine, Edwardina Otieno
2017-01-01
The aim of this study is to present data of the diagnostic capacity of Kenyan laboratories to diagnose a number of human pathogens. The study is based on the data obtained from a biosecurity survey conducted in Kenya in 2014/2015 and data from the Statistical Abstract of Kenya for 2015. The biosecurity survey has previously been published; however, the survey also included information on laboratory capacity to handle a number of pathogens, which have not been published. Data were retrieved from the survey on 86 laboratory facilities. The data include information from relevant categories such as training laboratories, human diagnostic laboratories, veterinary diagnostic laboratories, and research laboratories. The disease incidence in Kenya ranges widely from malaria and diarrhea with an incidence rate of around 10.000 per year to diseases such as cholera and yellow fever with an incidence rate of 1 per year or less for all age groups. The data showed that diseases with the highest number of diagnostic facilities were mainly malaria-, HIV-, tuberculosis-, and diarrhea-related infectious diseases. The study generally shows that the laboratory facilities have the capacity of detecting the infectious diseases with the highest incidence rates. Furthermore, it seems that the number of facilities able to detect a particular disease is related to the incidence rate of the disease.
Breakpoint structure of the Anopheles gambiae 2Rb chromosomal inversion.
Lobo, Neil F; Sangaré, Djibril M; Regier, Allison A; Reidenbach, Kyanne R; Bretz, David A; Sharakhova, Maria V; Emrich, Scott J; Traore, Sekou F; Costantini, Carlo; Besansky, Nora J; Collins, Frank H
2010-10-25
Alternative arrangements of chromosome 2 inversions in Anopheles gambiae are important sources of population structure, and are associated with adaptation to environmental heterogeneity. The forces responsible for their origin and maintenance are incompletely understood. Molecular characterization of inversion breakpoints provides insight into how they arose, and provides the basis for development of molecular karyotyping methods useful in future studies. Sequence comparison of regions near the cytological breakpoints of 2Rb allowed the molecular delineation of breakpoint boundaries. Comparisons were made between the standard 2R+b arrangement in the An. gambiae PEST reference genome and the inverted 2Rb arrangements in the An. gambiae M and S genome assemblies. Sequence differences between alternative 2Rb arrangements were exploited in the design of a PCR diagnostic assay, which was evaluated against the known chromosomal banding pattern of laboratory colonies and field-collected samples from Mali and Cameroon. The breakpoints of the 7.55 Mb 2Rb inversion are flanked by extensive runs of the same short (72 bp) tandemly organized sequence, which was likely responsible for chromosomal breakage and rearrangement. Application of the molecular diagnostic assay suggested that 2Rb has a single common origin in An. gambiae and its sibling species, Anopheles arabiensis, and also that the standard arrangement (2R+b) may have arisen twice through breakpoint reuse. The molecular diagnostic was reliable when applied to laboratory colonies, but its accuracy was lower in natural populations. The complex repetitive sequence flanking the 2Rb breakpoint region may be prone to structural and sequence-level instability. The 2Rb molecular diagnostic has immediate application in studies based on laboratory colonies, but its usefulness in natural populations awaits development of complementary molecular tools.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) or § 414.509(a)(3) that the basis for payment for a new test will be gapfilling, CMS posts interim... for a new clinical diagnostic laboratory test. 414.509 Section 414.509 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests...
Aarsand, Aasne K; Villanger, Jørild H; Støle, Egil; Deybach, Jean-Charles; Marsden, Joanne; To-Figueras, Jordi; Badminton, Mike; Elder, George H; Sandberg, Sverre
2011-11-01
The porphyrias are a group of rare metabolic disorders whose diagnosis depends on identification of specific patterns of porphyrin precursor and porphyrin accumulation in urine, blood, and feces. Diagnostic tests for porphyria are performed by specialized laboratories in many countries. Data regarding the analytical and diagnostic performance of these laboratories are scarce. We distributed 5 sets of multispecimen samples from different porphyria patients accompanied by clinical case histories to 18-21 European specialist porphyria laboratories/centers as part of a European Porphyria Network organized external analytical and postanalytical quality assessment (EQA) program. The laboratories stated which analyses they would normally have performed given the case histories and reported results of all porphyria-related analyses available, interpretative comments, and diagnoses. Reported diagnostic strategies initially showed considerable diversity, but the number of laboratories applying adequate diagnostic strategies increased during the study period. We found an average interlaboratory CV of 50% (range 12%-152%) for analytes in absolute concentrations. Result normalization by forming ratios to the upper reference limits did not reduce this variation. Sixty-five percent of reported results were within biological variation-based analytical quality specifications. Clinical interpretation of the obtained analytical results was accurate, and most laboratories established the correct diagnosis in all distributions. Based on a case-based EQA scheme, variations were apparent in analytical and diagnostic performance between European specialist porphyria laboratories. Our findings reinforce the use of EQA schemes as an essential tool to assess both analytical and diagnostic processes and thereby to improve patient care in rare diseases.
Jia, Tingting; Zhang, Lei; Wang, Guojing; Zhang, Rui; Zhang, Kuo; Lin, Guigao; Xie, Jiehong; Wang, Lunan; Li, Jinming
2015-01-01
In recent years, nucleic acid tests for detection of measles virus RNA have been widely applied in laboratories belonging to the measles surveillance system of China. An external quality assessment program was established by the National Center for Clinical Laboratories to evaluate the performance of nucleic acid tests for measles virus. The external quality assessment panel, which consisted of 10 specimens, was prepared using armored RNAs, complex of noninfectious MS2 bacteriophage coat proteins encapsulated RNA of measles virus, as measles virus surrogate controls. Conserved sequences amplified from a circulating measles virus strain or from a vaccine strain were encapsulated into these armored RNAs. Forty-one participating laboratories from 15 provinces, municipalities, or autonomous regions that currently conduct molecular detection of measles virus enrolled in the external quality assessment program, including 40 measles surveillance system laboratories and one diagnostic reagent manufacturer. Forty laboratories used commercial reverse transcription-quantitative PCR kits, with only one laboratory applying a conventional PCR method developed in-house. The results indicated that most of the participants (38/41, 92.7%) were able to accurately detect the panel with 100% sensitivity and 100% specificity. Although a wide range of commercially available kits for nucleic acid extraction and reverse transcription polymerase chain reaction were used by the participants, only two false-negative results and one false-positive result were generated; these were generated by three separate laboratories. Both false-negative results were obtained with tests performed on specimens with the lowest concentration (1.2 × 104 genomic equivalents/mL). In addition, all 18 participants from Beijing achieved 100% sensitivity and 100% specificity. Overall, we conclude that the majority of the laboratories evaluated have reliable diagnostic capacities for the detection of measles virus. PMID:26244795
Zhang, Dong; Sun, Yu; Jia, Tingting; Zhang, Lei; Wang, Guojing; Zhang, Rui; Zhang, Kuo; Lin, Guigao; Xie, Jiehong; Wang, Lunan; Li, Jinming
2015-01-01
In recent years, nucleic acid tests for detection of measles virus RNA have been widely applied in laboratories belonging to the measles surveillance system of China. An external quality assessment program was established by the National Center for Clinical Laboratories to evaluate the performance of nucleic acid tests for measles virus. The external quality assessment panel, which consisted of 10 specimens, was prepared using armored RNAs, complex of noninfectious MS2 bacteriophage coat proteins encapsulated RNA of measles virus, as measles virus surrogate controls. Conserved sequences amplified from a circulating measles virus strain or from a vaccine strain were encapsulated into these armored RNAs. Forty-one participating laboratories from 15 provinces, municipalities, or autonomous regions that currently conduct molecular detection of measles virus enrolled in the external quality assessment program, including 40 measles surveillance system laboratories and one diagnostic reagent manufacturer. Forty laboratories used commercial reverse transcription-quantitative PCR kits, with only one laboratory applying a conventional PCR method developed in-house. The results indicated that most of the participants (38/41, 92.7%) were able to accurately detect the panel with 100% sensitivity and 100% specificity. Although a wide range of commercially available kits for nucleic acid extraction and reverse transcription polymerase chain reaction were used by the participants, only two false-negative results and one false-positive result were generated; these were generated by three separate laboratories. Both false-negative results were obtained with tests performed on specimens with the lowest concentration (1.2 × 104 genomic equivalents/mL). In addition, all 18 participants from Beijing achieved 100% sensitivity and 100% specificity. Overall, we conclude that the majority of the laboratories evaluated have reliable diagnostic capacities for the detection of measles virus.
[Coagulation Monitoring and Bleeding Management in Cardiac Surgery].
Bein, Berthold; Schiewe, Robert
2018-05-01
The transfusion of allogeneic blood products is associated with increased morbidity and mortality. An impaired hemostasis is frequently found in patients undergoing cardiac surgery and may in turn cause bleeding and transfusions. A goal directed coagulation management addressing the often complex coagulation disorders needs sophisticated diagnostics. This may improve both patients' outcome and costs. Recent data suggest that coagulation management based on a rational algorithm is more effective than traditional therapy based on conventional laboratory variables such as PT and INR. Platelet inhibitors, cumarins, direct oral anticoagulants and heparin need different diagnostic and therapeutic approaches. An algorithm specifically developed for use during cardiac surgery is presented. Georg Thieme Verlag KG Stuttgart · New York.
Yee, JoAnn L.; Vandeford, Thomas H.; Didier, Elizabeth S.; Gray, Stanton; Lewis, Anne; Roberts, Jeffrey; Taylor, Kerry; Bohm, Rudolf P.
2016-01-01
Specific Pathogen Free (SPF) macaques provide valuable animal models for biomedical research. In 1989 the National Center for Research Resources (now Office of Research Infrastructure Programs ORIP) of the National Institutes of Health initiated experimental research contracts to establish and maintain SPF colonies. The derivation and maintenance of SPF macaque colonies is a complex undertaking requiring knowledge of the biology of the agents for exclusion and normal physiology and behavior of macaques, application of the latest diagnostic technology, facilities management, and animal husbandry. This review provides information on the biology of the four viral agents targeted for exclusion in ORIP SPF macaque colonies, describes current state-of-the-art viral diagnostic algorithms, presents data from proficiency testing of diagnostic assays between laboratories at institutions participating in the ORIP SPF program, and outlines management strategies for maintaining the integrity of SPF colonies using results of diagnostic testing as a guide to decision making. PMID:26932456
van Kampen, Sanne C.; Oskam, Linda; Tuijn, Coosje J.; Klatser, Paul R.
2012-01-01
Background Successful integration of new diagnostics in national tuberculosis (TB) control programs, also called ‘retooling’, is highly dependent on operational aspects related to test availability, accessibility and affordability. This survey aimed to find out whether recommendations to use new diagnostics lead to successful retooling in high TB endemic countries, using immunochromatographic tests (ICTs) for TB culture speciation as a case study. ICTs are recommended to accurately confirm the presence of bacteria of the Mycobacterium tuberculosis complex in liquid culture isolates. Methods and Findings Questionnaires were sent to national TB reference laboratories (NRLs) in 42 high TB endemic countries to address their access to information on ICT implementation, logistics related to availability, accessibility and affordability of ICTs, and testing algorithms. Results from 16 responding countries indicated that half of the NRLs were aware of the contents of WHO guidance documents on liquid culture and ICT implementation, as well as their eligibility for a negotiated pricing agreement for ICT procurement. No major issues with availability and accessibility of ICTs were raised. When asked about testing algorithms, ICTs were not used as stand-alone or first test for TB culture identification as recommended by WHO. Conclusions The low response rate was a limitation of this survey and together with NRLs managers' unawareness of global guidance, suggests a lack of effective communication between partners of the global laboratory network and NRLs. TB tests could become more affordable to high TB endemic countries, if the possibility to negotiate lower prices for commercial products is communicated to them more successfully. NRLs need additional guidance to identify where available technologies can be most usefully implemented and in what order, taking into account long-term laboratory strategies. PMID:22937050
Code of Federal Regulations, 2013 CFR
2013-10-01
...) or § 414.509(a)(3) that the basis for payment for a new test will be gapfilling, CMS posts interim... for a new clinical diagnostic laboratory test. 414.509 Section 414.509 Public Health CENTERS FOR... Laboratory Tests § 414.509 Reconsideration of basis for and amount of payment for a new clinical diagnostic...
Samson, Lasse L; Pape-Haugaard, Louise; Meltzer, Michelle C; Fuchs, Martin; Schønheyder, Henrik C; Hejlesen, Ole
2016-03-18
User mobility is an important aspect of the development of clinical information systems for health care professionals. Mobile phones and tablet computers have obtained widespread use by health care professionals, offering an opportunity for supporting the access to patient information through specialized applications (apps) while supporting the mobility of the users. The use of apps for mobile phones and tablet computers may support workflow of complex tasks, for example, molecular-based diagnostic tests in clinical microbiology. Multiplex Blood Culture Test (MuxBCT) is a molecular-based diagnostic test used for rapid identification of pathogens in positive blood cultures. To facilitate the workflow of the MuxBCT, a specialized tablet computer app was developed as an accessory to the diagnostic test. The app aims to reduce the complexity of the test by step-by-step guidance of microscopy and to assist users in reaching an exact bacterial or fungal diagnosis based on blood specimen observations and controls. Additionally, the app allows for entry of test results, and communication thereof to the laboratory information system (LIS). The objective of the study was to describe the design considerations of the MuxBCT app and the results of a preliminary usability evaluation. The MuxBCT tablet app was developed and set up for use in a clinical microbiology laboratory. A near-live simulation study was conducted in the clinical microbiology laboratory to evaluate the usability of the MuxBCT app. The study was designed to achieve a high degree of realism as participants carried out a scenario representing the context of use for the MuxBCT app. As the MuxBCT was under development, the scenario involved the use of molecular blood culture tests similar to the MuxBCT for identification of microorganisms from positive blood culture samples. The study participants were observed, and their interactions with the app were recorded. After the study, the participants were debriefed to clarify observations. Four medical laboratory technicians, for example, representative of end users of the app, participated in the clinical simulation study. Using the MuxBCT app, the study participants successfully identified and reported all microorganisms from the positive blood cultures examined. Three of the four participants reported that they found the app useful, while one study participant reported that she would prefer to make notes on paper and later enter them into the LIS. The preliminary usability evaluation results indicate that use of the MuxBCT tablet app can facilitate the workflow of the MuxBCT diagnostic test.
Basic haemoglobinopathy diagnostics in Dutch laboratories; providing an informative test result.
Kaufmann, J O; Smit, J W; Huisman, W; Idema, R N; Bakker, E; Giordano, P C
2013-08-01
After a first survey in 2001, the Dutch Association of Hematological Laboratory Research (VHL) advised its members to adopt a basic protocol for haemoglobinopathy carrier detection and to provide genetic information with all positive results to allow health-care professionals to inform carriers about potential genetic risks. This article reports on the compliance with these recommendations and their consequences. Clinical chemists of all 106 Dutch laboratories were invited to answer a survey on patient population, diagnostic techniques used, (self-reported) knowledge, use and effect of the additional information. The average increase in diagnostic output was over 60% and the recommended basic protocol was applied by 65% of the laboratories. Over 84% of the laboratories reported to be aware of the additional recommendations and 77% to be using them. Most laboratories with limited diagnostic requests were still sending their cases to other laboratories and included the genetic information received from these laboratories in their diagnostic reports. The effect of information on subsequent 'family analysis' was estimated to be between 26 and 50%. The present study shows an increase in diagnostic potential for haemoglobinopathy over the last decade, especially in the larger cities. Low 'family testing' rates were mostly found in areas with lower carrier prevalence or associated with local reluctance to pass the information to carriers. In spite of a dramatic improvement, too many carriers are still not informed because of lack of awareness among health-care providers and more education is needed. © 2012 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Bezruchko, Konstantin; Davidov, Albert
2009-01-01
In the given article scientific and technical complex for modeling, researching and testing of rocket-space vehicles' power installations which was created in Power Source Laboratory of National Aerospace University "KhAI" is described. This scientific and technical complex gives the opportunity to replace the full-sized tests on model tests and to reduce financial and temporary inputs at modeling, researching and testing of rocket-space vehicles' power installations. Using the given complex it is possible to solve the problems of designing and researching of rocket-space vehicles' power installations efficiently, and also to provide experimental researches of physical processes and tests of solar and chemical batteries of rocket-space complexes and space vehicles. Scientific and technical complex also allows providing accelerated tests, diagnostics, life-time control and restoring of chemical accumulators for rocket-space vehicles' power supply systems.
Rahmadane, Ibnu; Certoma, Andrea F; Peck, Grantley R; Fitria, Yul; Payne, Jean; Colling, Axel; Shiell, Brian J; Beddome, Gary; Wilson, Susanne; Yu, Meng; Morrissy, Chris; Michalski, Wojtek P; Bingham, John; Gardner, Ian A; Allen, John D
2017-11-01
Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT), which is considered the reference (gold standard) test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller's stain test, SST). This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD) test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE)-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST (median = 0.562). Proficiency testing using a panel of 6 coded samples distributed to 16 laboratories showed that the RIAD test had good reproducibility with an overall agreement of 97%. This study describes the successful development, characterisation and use of a novel RIAD test and its fitness for purpose as a screening test for use in provincial Indonesian veterinary laboratories.
Shrivastava, Kamal; Garima, Kushal; Narang, Anshika; Bhattacharyya, Kausik; Vishnoi, Ekta; Singh, Roshan Kumar; Chaudhry, Anil; Prasad, Rajendra; Bose, Mridula; Varma-Basil, Mandira
2017-03-01
We explored the efficiency of Rv1458c, the gene encoding a putative ABC drug transporter specific for the Mycobacterium tuberculosis complex (MTBC), as a diagnostic marker. A 190 bp region of Rv1458c and a 300 bp region of hsp65 were targeted in a novel duplex PCR assay and the results were compared with those for PCR restriction analysis(PRA) using the restriction enzymes NruI and BamHI. Species identification of a subset of the isolates (n=50) was confirmed by sequencing. Clinical isolates of M. tuberculosis (n=426) obtained from clinically suspected patients of pulmonary tuberculosis and mycobacterial (n=13) and non-mycobacterial (n=8) reference strains were included in the study. The duplex PCR assay correctly identified 320/426 isolates as MTBC and 106/426 isolates as non-tuberculous mycobacteria(NTM). The test was 100 % specific and sensitive when compared with NruI/BamHI PCR restriction analysis and highlighted the use of Rv1458c as a diagnostic marker for MTBC. The duplex PCR assay could be developed for use as a screening test to identify MTBC in clinical specimens in peripheral laboratories with limited resources.
Kusters, Elske; Kerkhoffs, Jean-Louis H; van Rossum, André P
2014-01-01
The thalassaemias are characterised by quantitative aberrations in the production of the globin chains that make up haemoglobin, and are a subgroup of the haemoglobinopathies. In this LabQuiz we show how thalassaemia carrier status can be indicated in the results of regular laboratory tests, and discuss the laboratory diagnostics that can confirm or rule out thalassaemia. In these two cases we will present a man of Moroccan descent, and two brothers of Filipino descent, all with anaemia and microcytosis. We show it is possible to differentiate between iron-deficiency anaemia and thalassaemia carrier status on the basis of a complete blood count and measurement of ferritin levels, and which laboratory diagnostics can be subsequently performed in order to confirm a suspicion of thalassaemia. The background section discusses the properties and pitfalls of routine laboratory diagnostics for the thalassaemias, and thalassaemia diagnostics in the Dutch newborn screening programme.
National NIF Diagnostic Program Fiscal Year 2002 Second Quarter Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacGowan, B
Since October 2001 the development of the facility diagnostics for NIF has been funded by the NIF Director through the National NIF Diagnostic Program (NNDP). The current emphasis of the NNDP is on diagnostics for the early NIF quad scheduled to be available for experiment commissioning in FY03. During the past six months the NNDP has set in place processes for funding diagnostics, developing requirements for diagnostics, design reviews and monthly status reporting. Those processes are described in an interim management plan for diagnostics (''National NIF Diagnostic Program Interim Plan'', NIF-0081315, April 2002) and a draft Program Execution Plan (''Programmore » Execution Plan for the National NlF Diagnostic Program'', NIF-0072083, October 2001) and documents cited therein. Work has been funded at Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Naval Research Laboratory (NRL), Sandia National Laboratories (SNL), Bechtel Nevada at Los Alamos and Santa Barbara. There are no major technical risks with the early diagnostics. The main concerns relate to integration of the diagnostics into the facility, all such issues are being worked. This report is organized to show the schedule and budget status and a summary of Change Control Board actions for the past six months. The following sections then provide short descriptions of the status of each diagnostic. Where design reviews or requirements documents are cited, the documents are available on the Diagnostics file server or on request.« less
[Human coronavirus infections: importance and diagnosis].
Vabret, A; Brouard, J; Petitjean, J; Eugene-Ruellan, G; Freymuth, F
1998-11-14
POORLY-KNOWN VIRUS: Coronaviruses, so named because of their sun-ray-like aspect, were discovered in the sixties. The biology of these RNA viruses is complex and poorly understood. KNOWN PATHOGENS: Coronaviruses are known pathogens in veterinary medicine, causing disease states in several domestic species. In human medicine, they can cause benign respiratory infections, but few laboratories include coronaviruses in their routine diagnostic tests. SUSPECTED PATHOGENS: There is some data in the literature suggesting coronaviruses might be implicated in more severe diseases including multiple sclerosis, necrotizing enterocolitis, and lower respiratory tract infections, particularly in infants. IMPROVING DIAGNOSTIC METHODS: Due to the lack of reliable and sensitive diagnostic techniques, it is impossible to date to correctly assess the medical impact of these ubiquitous and endemic viruses. Molecular biology techniques enabling detection of human coronavirus infections should be applied to verifying the suspected implication of these viruses in diverse disease states.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zafar, A., E-mail: zafara@ornl.gov; Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830; Martin, E. H.
2016-11-15
An electron density diagnostic (≥10{sup 10} cm{sup −3}) capable of high temporal (ms) and spatial (mm) resolution is currently under development at Oak Ridge National Laboratory. The diagnostic is based on measuring the Stark broadened, Doppler-free spectral line profile of the n = 6–2 hydrogen Balmer series transition. The profile is then fit to a fully quantum mechanical model including the appropriate electric and magnetic field operators. The quasi-static approach used to calculate the Doppler-free spectral line profile is outlined here and the results from the model are presented for H-δ spectra for electron densities of 10{sup 10}–10{sup 13} cm{supmore » −3}. The profile shows complex behavior due to the interaction between the magnetic substates of the atom.« less
The role of flow cytometry in companion animal diagnostic medicine.
Tarrant, Jacqueline M
2005-11-01
Flow cytometry is a powerful tool for characterising the composition of complex cell populations. The accuracy and precision of this technology for describing and enumerating cells exceeds traditional methods. The number of diagnostic veterinary laboratories with access to a dedicated machine is increasing, and there is the potential to offer a clinical flow cytometry service. The improved availability of monoclonal antibodies (mAb) to cell markers expressed by the leukocytes of companion animals, permits the implementation of comprehensive mAb panels suitable for diagnosis of lympho- and myeloproliferative disease. Reticulated erythrocyte and platelet quantification, antiglobulin assays for immune-mediated cytopenias, lymphocyte subset analysis, and immunophenotyping of lymphoma and leukemia, have been validated for companion animal samples on the flow cytometer. It is now timely to consider the role of flow cytometry in diagnostic practice, and the requirement for quality assurance and standardization of testing procedures.
Swaminathan, Rajeswari; Huang, Yungui; Miller, Katherine; Pastore, Matthew; Hashimoto, Sayaka; Jacobson, Theodora; Mouhlas, Danielle; Lin, Simon
2018-01-01
The adoption rate of genome sequencing for clinical diagnostics has been steadily increasing leading to the possibility of improvement in diagnostic yields. Although laboratories generate a summary clinical report, sharing raw genomic data with healthcare providers is equally important, both for secondary research studies as well as for a deeper analysis of the data itself, as seen by the efforts from organizations such as American College of Medical Genetics and Genomics and Global Alliance for Genomics and Health. Here, we aim to describe the existing protocol of genomic data sharing between a certified clinical laboratory and a healthcare provider and highlight some of the lessons learned. This study tracked and subsequently evaluated the data transfer workflow for 19 patients, all of whom consented to be part of this research study and visited the genetics clinic at a tertiary pediatric hospital between April 2016 to December 2016. Two of the most noticeable elements observed through this study are the manual validation steps and the discrepancies in patient identifiers used by a clinical lab vs. healthcare provider. Both of these add complexity to the transfer process as well as make it more susceptible to errors. The results from this study highlight some of the critical changes that need to be made in order to improve genomic data sharing workflows between healthcare providers and clinical sequencing laboratories. PMID:29515625
76 FR 76736 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-08
... Project Survey of Rapid Influenza Diagnostic Test (RIDT) Practices in Laboratories-NEW--the Office of...). Background and Brief Description The Survey of Rapid Influenza Diagnostic Testing Practices in Laboratories is a national systematic study investigating rapid influenza diagnostic testing practices in clinical...
Purcell, Maureen K.; Getchell, Rodman G.; McClure, Carol A.; Weber, S.E.; Garver, Kyle A.
2011-01-01
Real-time, or quantitative, polymerase chain reaction (qPCR) is quickly supplanting other molecular methods for detecting the nucleic acids of human and other animal pathogens owing to the speed and robustness of the technology. As the aquatic animal health community moves toward implementing national diagnostic testing schemes, it will need to evaluate how qPCR technology should be employed. This review outlines the basic principles of qPCR technology, considerations for assay development, standards and controls, assay performance, diagnostic validation, implementation in the diagnostic laboratory, and quality assurance and control measures. These factors are fundamental for ensuring the validity of qPCR assay results obtained in the diagnostic laboratory setting.
Wound Healing Finally Enters the Age of Molecular Diagnostic Medicine
Tatum, Owatha L.; Dowd, Scot E.
2012-01-01
Background Many wounds are difficult to heal because of the large, complex community of microbes present within the wound. The Problem Classical laboratory culture methods do not provide an accurate picture of the microbial interactions or representation of microorganisms within a wound. There is an inherent bias in diagnosis based upon classical culture stemming from the ability of certain organisms to thrive in culture while others are underrepresented or fail to be identified in culture altogether. Chronic wounds also contain polymicrobial infections existing as a cooperative community that is resistant to antibiotic therapy. Basic/Clinical Science Advances New methods in molecular diagnostic medicine allow the identification of nearly all organisms present in a wound irrespective of the ability of these organisms to be grown in culture. Advances in DNA analyses allow absolute identification of microorganisms from very small clinical specimens. These new methods also provide a quantitative representation of all microorganisms contributing to these polymicrobial infections. Clinical Care Relevance Technological advances in laboratory diagnostics can significantly shorten the time required to heal chronic wounds. Identification of the genetic signatures of organisms present within a wound allows clinicians to identify and treat the primary organisms responsible for nonhealing wounds. Conclusion Advanced genetic technologies targeting the specific needs of wound care patients are now accessible to all wound care clinicians. PMID:24527290
Clonality Testing in Veterinary Medicine: A Review With Diagnostic Guidelines.
Keller, S M; Vernau, W; Moore, P F
2016-07-01
The accurate distinction of reactive and neoplastic lymphoid proliferations can present challenges. Given the different prognoses and treatment strategies, a correct diagnosis is crucial. Molecular clonality assays assess rearranged lymphocyte antigen receptor gene diversity and can help differentiate reactive from neoplastic lymphoid proliferations. Molecular clonality assays are commonly used to assess atypical, mixed, or mature lymphoid proliferations; small tissue fragments that lack architecture; and fluid samples. In addition, clonality testing can be utilized to track neoplastic clones over time or across anatomic sites. Molecular clonality assays are not stand-alone tests but useful adjuncts that follow clinical, morphologic, and immunophenotypic assessment. Even though clonality testing provides valuable information in a variety of situations, the complexities and pitfalls of this method, as well as its dependency on the experience of the interpreter, are often understated. In addition, a lack of standardized terminology, laboratory practices, and interpretational guidelines hinders the reproducibility of clonality testing across laboratories in veterinary medicine. The objectives of this review are twofold. First, the review is intended to familiarize the diagnostic pathologist or interested clinician with the concepts, potential pitfalls, and limitations of clonality testing. Second, the review strives to provide a basis for future harmonization of clonality testing in veterinary medicine by providing diagnostic guidelines. © The Author(s) 2016.
Lewis, Suzanna M.; Lansley, Amber; Fraser, Sara; Shieber, Clare; Shah, Sonal; Semper, Amanda; Bailey, Daniel; Busuttil, Jason; Evans, Liz; Carroll, Miles W.; Silman, Nigel J.; Brooks, Tim; Shallcross, Jane A.
2017-01-01
As part of the UK response to the 2013–2016 Ebola virus disease (EVD) epidemic in West Africa, Public Health England (PHE) were tasked with establishing three field Ebola virus (EBOV) diagnostic laboratories in Sierra Leone by the UK Department for International Development (DFID). These provided diagnostic support to the Ebola Treatment Centre (ETC) facilities located in Kerry Town, Makeni and Port Loko. The Novel and Dangerous Pathogens (NADP) Training group at PHE, Porton Down, designed and implemented a pre-deployment Ebola diagnostic laboratory training programme for UK volunteer scientists being deployed to the PHE EVD laboratories. Here, we describe the training, workflow and capabilities of these field laboratories for use in response to disease epidemics and in epidemiological surveillance. We discuss the training outcomes, the laboratory outputs, lessons learned and the legacy value of the support provided. We hope this information will assist in the recruitment and training of staff for future responses and in the design and implementation of rapid deployment diagnostic field laboratories for future outbreaks of high consequence pathogens. This article is part of the themed issue ‘The 2013–2016 West African Ebola epidemic: data, decision-making and disease control’. PMID:28396470
Intelligent diagnosis of jaundice with dynamic uncertain causality graph model.
Hao, Shao-Rui; Geng, Shi-Chao; Fan, Lin-Xiao; Chen, Jia-Jia; Zhang, Qin; Li, Lan-Juan
2017-05-01
Jaundice is a common and complex clinical symptom potentially occurring in hepatology, general surgery, pediatrics, infectious diseases, gynecology, and obstetrics, and it is fairly difficult to distinguish the cause of jaundice in clinical practice, especially for general practitioners in less developed regions. With collaboration between physicians and artificial intelligence engineers, a comprehensive knowledge base relevant to jaundice was created based on demographic information, symptoms, physical signs, laboratory tests, imaging diagnosis, medical histories, and risk factors. Then a diagnostic modeling and reasoning system using the dynamic uncertain causality graph was proposed. A modularized modeling scheme was presented to reduce the complexity of model construction, providing multiple perspectives and arbitrary granularity for disease causality representations. A "chaining" inference algorithm and weighted logic operation mechanism were employed to guarantee the exactness and efficiency of diagnostic reasoning under situations of incomplete and uncertain information. Moreover, the causal interactions among diseases and symptoms intuitively demonstrated the reasoning process in a graphical manner. Verification was performed using 203 randomly pooled clinical cases, and the accuracy was 99.01% and 84.73%, respectively, with or without laboratory tests in the model. The solutions were more explicable and convincing than common methods such as Bayesian Networks, further increasing the objectivity of clinical decision-making. The promising results indicated that our model could be potentially used in intelligent diagnosis and help decrease public health expenditure.
Intelligent diagnosis of jaundice with dynamic uncertain causality graph model*
Hao, Shao-rui; Geng, Shi-chao; Fan, Lin-xiao; Chen, Jia-jia; Zhang, Qin; Li, Lan-juan
2017-01-01
Jaundice is a common and complex clinical symptom potentially occurring in hepatology, general surgery, pediatrics, infectious diseases, gynecology, and obstetrics, and it is fairly difficult to distinguish the cause of jaundice in clinical practice, especially for general practitioners in less developed regions. With collaboration between physicians and artificial intelligence engineers, a comprehensive knowledge base relevant to jaundice was created based on demographic information, symptoms, physical signs, laboratory tests, imaging diagnosis, medical histories, and risk factors. Then a diagnostic modeling and reasoning system using the dynamic uncertain causality graph was proposed. A modularized modeling scheme was presented to reduce the complexity of model construction, providing multiple perspectives and arbitrary granularity for disease causality representations. A “chaining” inference algorithm and weighted logic operation mechanism were employed to guarantee the exactness and efficiency of diagnostic reasoning under situations of incomplete and uncertain information. Moreover, the causal interactions among diseases and symptoms intuitively demonstrated the reasoning process in a graphical manner. Verification was performed using 203 randomly pooled clinical cases, and the accuracy was 99.01% and 84.73%, respectively, with or without laboratory tests in the model. The solutions were more explicable and convincing than common methods such as Bayesian Networks, further increasing the objectivity of clinical decision-making. The promising results indicated that our model could be potentially used in intelligent diagnosis and help decrease public health expenditure. PMID:28471111
Vasson, Aurélie; Leroux, Céline; Orhant, Lucie; Boimard, Mathieu; Toussaint, Aurélie; Leroy, Chrystel; Commere, Virginie; Ghiotti, Tiffany; Deburgrave, Nathalie; Saillour, Yoann; Atlan, Isabelle; Fouveaut, Corinne; Beldjord, Cherif; Valleix, Sophie; Leturcq, France; Dodé, Catherine; Bienvenu, Thierry; Chelly, Jamel; Cossée, Mireille
2013-01-01
The frequency of disease-related large rearrangements (referred to as copy-number mutations, CNMs) varies among genes, and search for these mutations has an important place in diagnostic strategies. In recent years, CGH method using custom-designed high-density oligonucleotide-based arrays allowed the development of a powerful tool for detection of alterations at the level of exons and made it possible to provide flexibility through the possibility of modeling chips. The aim of our study was to test custom-designed oligonucleotide CGH array in a diagnostic laboratory setting that analyses several genes involved in various genetic diseases, and to compare it with conventional strategies. To this end, we designed a 12-plex CGH array (135k; 135 000 probes/subarray) (Roche Nimblegen) with exonic and intronic oligonucleotide probes covering 26 genes routinely analyzed in the laboratory. We tested control samples with known CNMs and patients for whom genetic causes underlying their disorders were unknown. The contribution of this technique is undeniable. Indeed, it appeared reproducible, reliable and sensitive enough to detect heterozygous single-exon deletions or duplications, complex rearrangements and somatic mosaicism. In addition, it improves reliability of CNM detection and allows determination of boundaries precisely enough to direct targeted sequencing of breakpoints. All of these points, associated with the possibility of a simultaneous analysis of several genes and scalability ‘homemade' make it a valuable tool as a new diagnostic approach of CNMs. PMID:23340513
Condell, Orla; Wasunna, Christine; Kpaka, Jonathan; Zwizwai, Ruth; Nuha, Mahmood; Fallah, Mosoka; Freeman, Maxwell; Harris, Victoria; Miller, Mark; Baller, April; Massaquoi, Moses; Katawera, Victoria; Saindon, John; Bemah, Philip; Hamblion, Esther; Castle, Evelyn; Williams, Desmond; Gasasira, Alex; Nyenswah, Tolbert
2018-01-01
The 2014–16 Ebola Virus Disease (EVD) outbreak in West Africa highlighted the necessity for readily available, accurate and rapid diagnostics. The magnitude of the outbreak and the re-emergence of clusters of EVD cases following the declaration of interrupted transmission in Liberia, reinforced the need for sustained diagnostics to support surveillance and emergency preparedness. We describe implementation of the Xpert Ebola Assay, a rapid molecular diagnostic test run on the GeneXpert platform, at a mobile laboratory in Liberia and the subsequent impact on EVD outbreak response, case management and laboratory system strengthening. During the period of operation, site coordination, management and operational capacity was supported through a successful collaboration between Ministry of Health (MoH), World Health Organization (WHO) and international partners. A team of Liberian laboratory technicians were trained to conduct EVD diagnostics and the laboratory had capacity to test 64–100 blood specimens per day. Establishment of the laboratory significantly increased the daily testing capacity for EVD in Liberia, from 180 to 250 specimens at a time when the effectiveness of the surveillance system was threatened by insufficient diagnostic capacity. During the 18 months of operation, the laboratory tested a total of 9,063 blood specimens, including 21 EVD positives from six confirmed cases during two outbreaks. Following clearance of the significant backlog of untested EVD specimens in November 2015, a new cluster of EVD cases was detected at the laboratory. Collaboration between surveillance and laboratory coordination teams during this and a later outbreak in March 2016, facilitated timely and targeted response interventions. Specimens taken from cases during both outbreaks were analysed at the laboratory with results informing clinical management of patients and discharge decisions. The GeneXpert platform is easy to use, has relatively low running costs and can be integrated into other national diagnostic algorithms. The technology has on average a 2-hour sample-to-result time and allows for single specimen testing to overcome potential delays of batching. This model of a mobile laboratory equipped with Xpert Ebola test, staffed by local laboratory technicians, could serve to strengthen outbreak preparedness and response for future outbreaks of EVD in Liberia and the region. PMID:29304039
Raftery, Philomena; Condell, Orla; Wasunna, Christine; Kpaka, Jonathan; Zwizwai, Ruth; Nuha, Mahmood; Fallah, Mosoka; Freeman, Maxwell; Harris, Victoria; Miller, Mark; Baller, April; Massaquoi, Moses; Katawera, Victoria; Saindon, John; Bemah, Philip; Hamblion, Esther; Castle, Evelyn; Williams, Desmond; Gasasira, Alex; Nyenswah, Tolbert
2018-01-01
The 2014-16 Ebola Virus Disease (EVD) outbreak in West Africa highlighted the necessity for readily available, accurate and rapid diagnostics. The magnitude of the outbreak and the re-emergence of clusters of EVD cases following the declaration of interrupted transmission in Liberia, reinforced the need for sustained diagnostics to support surveillance and emergency preparedness. We describe implementation of the Xpert Ebola Assay, a rapid molecular diagnostic test run on the GeneXpert platform, at a mobile laboratory in Liberia and the subsequent impact on EVD outbreak response, case management and laboratory system strengthening. During the period of operation, site coordination, management and operational capacity was supported through a successful collaboration between Ministry of Health (MoH), World Health Organization (WHO) and international partners. A team of Liberian laboratory technicians were trained to conduct EVD diagnostics and the laboratory had capacity to test 64-100 blood specimens per day. Establishment of the laboratory significantly increased the daily testing capacity for EVD in Liberia, from 180 to 250 specimens at a time when the effectiveness of the surveillance system was threatened by insufficient diagnostic capacity. During the 18 months of operation, the laboratory tested a total of 9,063 blood specimens, including 21 EVD positives from six confirmed cases during two outbreaks. Following clearance of the significant backlog of untested EVD specimens in November 2015, a new cluster of EVD cases was detected at the laboratory. Collaboration between surveillance and laboratory coordination teams during this and a later outbreak in March 2016, facilitated timely and targeted response interventions. Specimens taken from cases during both outbreaks were analysed at the laboratory with results informing clinical management of patients and discharge decisions. The GeneXpert platform is easy to use, has relatively low running costs and can be integrated into other national diagnostic algorithms. The technology has on average a 2-hour sample-to-result time and allows for single specimen testing to overcome potential delays of batching. This model of a mobile laboratory equipped with Xpert Ebola test, staffed by local laboratory technicians, could serve to strengthen outbreak preparedness and response for future outbreaks of EVD in Liberia and the region.
Computerized provider order entry in the clinical laboratory
Baron, Jason M.; Dighe, Anand S.
2011-01-01
Clinicians have traditionally ordered laboratory tests using paper-based orders and requisitions. However, paper orders are becoming increasingly incompatible with the complexities, challenges, and resource constraints of our modern healthcare systems and are being replaced by electronic order entry systems. Electronic systems that allow direct provider input of diagnostic testing or medication orders into a computer system are known as Computerized Provider Order Entry (CPOE) systems. Adoption of laboratory CPOE systems may offer institutions many benefits, including reduced test turnaround time, improved test utilization, and better adherence to practice guidelines. In this review, we outline the functionality of various CPOE implementations, review the reported benefits, and discuss strategies for using CPOE to improve the test ordering process. Further, we discuss barriers to the implementation of CPOE systems that have prevented their more widespread adoption. PMID:21886891
Dequeker, Els; Stuhrmann, Manfred; Morris, Michael A; Casals, Teresa; Castellani, Carlo; Claustres, Mireille; Cuppens, Harry; des Georges, Marie; Ferec, Claude; Macek, Milan; Pignatti, Pier-Franco; Scheffer, Hans; Schwartz, Marianne; Witt, Michal; Schwarz, Martin; Girodon, Emmanuelle
2009-01-01
The increasing number of laboratories offering molecular genetic analysis of the CFTR gene and the growing use of commercial kits strengthen the need for an update of previous best practice guidelines (published in 2000). The importance of organizing regional or national laboratory networks, to provide both primary and comprehensive CFTR mutation screening, is stressed. Current guidelines focus on strategies for dealing with increasingly complex situations of CFTR testing. Diagnostic flow charts now include testing in CFTR-related disorders and in fetal bowel anomalies. Emphasis is also placed on the need to consider ethnic or geographic origins of patients and individuals, on basic principles of risk calculation and on the importance of providing accurate laboratory reports. Finally, classification of CFTR mutations is reviewed, with regard to their relevance to pathogenicity and to genetic counselling.
The Correlated Lecture Laboratory Series in Diagnostic Radiological Physics.
ERIC Educational Resources Information Center
Lamel, David A.; And Others
This series in diagnostic radiological physics has been designed to provide the physics background requisite for the proper conduct of medical diagnostic x-ray examinations. The basic goal of the series is to bridge physics theory and radiological practice, achieved by combining pertinent lecture material with laboratory exercises that illustrate…
Diagnostic trends in Clostridium difficile detection in Finnish microbiology laboratories.
Könönen, Eija; Rasinperä, Marja; Virolainen, Anni; Mentula, Silja; Lyytikäinen, Outi
2009-12-01
Due to increased interest directed to Clostridium difficile-associated infections, a questionnaire survey of laboratory diagnostics of toxin-producing C. difficile was conducted in Finland in June 2006. Different aspects pertaining to C. difficile diagnosis, such as requests and criteria used for testing, methods used for its detection, yearly changes in diagnostics since 1996, and the total number of investigations positive for C. difficile in 2005, were asked in the questionnaire, which was sent to 32 clinical microbiology laboratories, including all hospital-affiliated and the relevant private clinical microbiology laboratories in Finland. The situation was updated by phone and email correspondence in September 2008. In June 2006, 28 (88%) laboratories responded to the questionnaire survey; 24 of them reported routinely testing requested stool specimens for C. difficile. Main laboratory methods included toxin detection (21/24; 88%) and/or anaerobic culture (19/24; 79%). In June 2006, 18 (86%) of the 21 laboratories detecting toxins directly from feces, from the isolate, or both used methods for both toxin A (TcdA) and B (TcdB), whereas only one laboratory did so in 1996. By September 2008, all of the 23 laboratories performing diagnostics for C. difficile used methods for both TcdA and TcdB. In 2006, the number of specimens processed per 100,000 population varied remarkably between different hospital districts. In conclusion, culturing C. difficile is common and there has been a favorable shift in toxin detection practice in Finnish clinical microbiology laboratories. However, the variability in diagnostic activity reported in 2006 creates a challenge for national monitoring of the epidemiology of C. difficile and related diseases.
78 FR 60245 - Privacy Act Systems of Records; LabWare Laboratory Information Management System
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-01
... Services Laboratories (NVSL). Diagnostic testing provides official test results for animal imports, exports.... Diagnostic testing is also done in connection with suspected foreign animal disease investigations and... of Records; LabWare Laboratory Information Management System AGENCY: Animal and Plant Health...
Dorizzi, R M; Maconi, M; Giavarina, D; Loza, G; Aman, M; Moreira, J; Bisoffi, Z; Gennuso, C
2009-10-01
The adoption of Evidence Based Laboratory Medicine (EBLM) has been hampered until today by the lack of effective tools. The SIMeL EBLM e-Thesaurus (on-line Repertoire of the diagnostic effectiveness of the laboratory, radiology and cardiology test) provides a useful support to clinical laboratory professionals and to clinicians for the interpretation of the diagnostic tests. The e-Thesaurus is an application developed using Microsoft Active Server Pages technology and carried out with Web Server Microsoft Internet Information Server and is available at the SIMeL website using a browser running JavaScript scripts (Internet Explorer is recommended). It contains a database (in Italian, English and Spanish) of the sensitivity and specificity (including the 95% confidence interval), the positive and negative likelihood ratios, the Diagnostic Odds Ratio and the Number Needed to Diagnose of more than 2000 diagnostic (most laboratory but also cardiology and radiology) tests. The e-Thesaurus improves the previous SIMeL paper and CD Thesaurus; its main features are a three languages search and a continuous and an easy updating capability.
Quality systems in veterinary diagnostics laboratories.
de Branco, Freitas Maia L M
2007-01-01
Quality assurance of services provided by veterinary diagnostics laboratories is a fundamental element promoted by international animal health organizations to establish trust, confidence and transparency needed for the trade of animals and their products at domestic and international levels. It requires, among other things, trained personnel, consistent and rigorous methodology, choice of suitable methods as well as appropriate calibration and traceability procedures. An important part of laboratory quality management is addressed by ISO/IEC 17025, which aims to facilitate cooperation among laboratories and their associated parties by assuring the generation of credible and consistent information derived from analytical results. Currently, according to OIE recommendation, veterinary diagnostics laboratories are only subject to voluntary compliance with standard ISO/IEC 17025; however, it is proposed here that OIE reference laboratories and collaboration centres strongly consider its adoption.
Clinical pathologist in Korea--training program and its roles in laboratories.
Cho, Han-Ik; Lee, Kap No; Park, Jong-Woo; Park, Hyosoon; Kwak, Yun Sik
2002-01-01
A rapid development of practice of laboratory medicine in Korea owes its success to the clinical pathologists (CP), who have played a role of a pathfinder for laboratories. The Korean CP postgraduate education (residency) program is unique in that it is exclusively for laboratory medicine. The training program for clinical pathologists includes diagnostic hematology, diagnostic immunology, clinical microbiology, clinical chemistry, blood bank, diagnostic genetics, informatics and laboratory management. The program has produced a strong group of about 600 laboratory physicians, officially clinical pathologists since 1963. Most of Korean clinical pathologists work as laboratory directors, directors of university hospital laboratories or teaching faculty members in medical schools. The roles of clinical pathologists are laboratory management, interpretation of laboratory test results, clinical consulting services to clinicians and patients, ordering secondary tests after reviews of requested test results and utilization management. The clinical pathologists have developed clinical laboratories to be a main contributor for improved medical practice. During the last 40 years under the turbulent healthcare system, clinical pathologists have significantly contributed to safeguard the laboratory interests. The education program and the role of clinical pathologists are described.
Moro, Marilyn; Westover, M Brandon; Kelly, Jessica; Bianchi, Matt T
2016-03-01
Obstructive sleep apnea (OSA) is associated with increased morbidity and mortality, and treatment with positive airway pressure (PAP) is cost-effective. However, the optimal diagnostic strategy remains a subject of debate. Prior modeling studies have not consistently supported the widely held assumption that home sleep testing (HST) is cost-effective. We modeled four strategies: (1) treat no one; (2) treat everyone empirically; (3) treat those testing positive during in-laboratory polysomnography (PSG) via in-laboratory titration; and (4) treat those testing positive during HST with auto-PAP. The population was assumed to lack independent reasons for in-laboratory PSG (such as insomnia, periodic limb movements in sleep, complex apnea). We considered the third-party payer perspective, via both standard (quality-adjusted) and pure cost methods. The preferred strategy depended on three key factors: pretest probability of OSA, cost of untreated OSA, and time horizon. At low prevalence and low cost of untreated OSA, the treat no one strategy was favored, whereas empiric treatment was favored for high prevalence and high cost of untreated OSA. In-laboratory backup for failures in the at-home strategy increased the preference for the at-home strategy. Without laboratory backup in the at-home arm, the in-laboratory strategy was increasingly preferred at longer time horizons. Using a model framework that captures a broad range of clinical possibilities, the optimal diagnostic approach to uncomplicated OSA depends on pretest probability, cost of untreated OSA, and time horizon. Estimating each of these critical factors remains a challenge warranting further investigation. © 2016 American Academy of Sleep Medicine.
External quality assessment of dengue and chikungunya diagnostics in the Asia Pacific region, 2015
Soh, Li Ting; Squires, Raynal C; Tan, Li Kiang; Pok, Kwoon Yong; Yang, HuiTing; Liew, Christina; Shah, Aparna Singh; Aaskov, John; Abubakar, Sazaly; Hasabe, Futoshi; Ng, Lee Ching
2016-01-01
Objective To conduct an external quality assessment (EQA) of dengue and chikungunya diagnostics among national-level public health laboratories in the Asia Pacific region following the first round of EQA for dengue diagnostics in 2013. Methods Twenty-four national-level public health laboratories performed routine diagnostic assays on a proficiency testing panel consisting of two modules. Module A contained serum samples spiked with cultured dengue virus (DENV) or chikungunya virus (CHIKV) for the detection of nucleic acid and DENV non-structural protein 1 (NS1) antigen. Module B contained human serum samples for the detection of anti-DENV antibodies. Results Among 20 laboratories testing Module A, 17 (85%) correctly detected DENV RNA by reverse transcription polymerase chain reaction (RT–PCR), 18 (90%) correctly determined serotype and 19 (95%) correctly identified CHIKV by RT–PCR. Ten of 15 (66.7%) laboratories performing NS1 antigen assays obtained the correct results. In Module B, 18/23 (78.3%) and 20/20 (100%) of laboratories correctly detected anti-DENV IgM and IgG, respectively. Detection of acute/recent DENV infection by both molecular (RT–PCR) and serological methods (IgM) was available in 19/24 (79.2%) participating laboratories. Discussion Accurate laboratory testing is a critical component of dengue and chikungunya surveillance and control. This second round of EQA reveals good proficiency in molecular and serological diagnostics of these diseases in the Asia Pacific region. Further comprehensive diagnostic testing, including testing for Zika virus, should comprise future iterations of the EQA. PMID:27508088
Human rabies in India: an audit from a rabies diagnostic laboratory.
Mani, Reeta Subramaniam; Anand, Ashwini Manoor; Madhusudana, Shampur Narayan
2016-04-01
Rabies, an acute progressive encephalomyelitis, continues to be a serious public health problem in India and many other countries in Asia and Africa. The low level of commitment to rabies control is partly attributable to challenges in laboratory diagnosis and lack of adequate surveillance to indicate the disease burden. A laboratory audit of human rabies cases was undertaken to disseminate information on the clinical, demographic, prophylactic and most importantly the laboratory diagnostic aspects of rabies. A retrospective analysis of all clinically suspected human rabies cases, whose samples were received at a rabies diagnostic laboratory in South India in the last 3 years, was performed. Clinical and demographic details of patients were obtained. The clinical samples included cerebrospinal fluid (CSF), serum, saliva and nuchal skin biopsy collected antemortem, and brain tissue obtained post-mortem. Various laboratory tests were performed for diagnosis. Clinical samples from 128 patients with suspected rabies, from 11 states in India, were received for diagnostic confirmation. About 94% of the victims reported dog-bites, more than a third of them were children and most of the victims did not receive adequate post-exposure prophylaxis. Antemortem confirmation of rabies by a combination of laboratory diagnostic assays (detection of viral RNA in CSF, skin and saliva, and neutralising antibodies in CSF) could be achieved in 40.6% cases. Increasing awareness about adequate post-exposure prophylaxis, additional rabies diagnostic facilities, and enhanced human and animal rabies surveillance to indicate the true disease burden are essential to control this fatal disease. © 2016 John Wiley & Sons Ltd.
Investigation of inner aerodynamics of the four-vortex furnace model
NASA Astrophysics Data System (ADS)
Anufriev, I. S.; Shadrin, E. Yu; Sharypov, O. V.
2018-03-01
The internal aerodynamics of a perspective vortex furnace chamber of a pulverized coal boiler with a diagonal arrangement of burners is studied using the non-contact optical method of flow diagnostics. The results of laser Doppler anemometry, characterizing the complex spatial structure of a swirling flow in an isothermal laboratory model of the furnace device, are presented. The velocity distribution in the vortex chamber volume is obtained, and the flow structure in the form of four conjugate closed vortices with curved axes is visualized.
Kolobukhina, L V; L'vov, D K; Butenko, A M; Kuznetsov, A A; Galkina, I V
1989-10-01
To study the role of viruses of the California encephalitis virus complex (the family Bunyaviridae) in infectious pathology, 187 fever patients admitted to the Clinical Infectious Hospital in May-September 1986 were examined. In 10 of these patients the neutralization test revealed the presence of diagnostically significant changes in neutralizing antibodies (neutralization indices), which was indicative of the role played by Tahyna virus or other related viruses belonging to the California encephalitis virus complex in the etiology of the diseases. The analysis of the clinical picture showed that in all patients the disease took an acute course in its initial stage, starting with shivering and characterized by high fever, headache, pronounced toxicosis, the possibility of the formation of intracerebral hypertension and pneumonia.
Pok, Kwoon Yong; Squires, Raynal C; Tan, Li Kiang; Takasaki, Tomohiko; Abubakar, Sazaly; Hasebe, Futoshi; Partridge, Jeffrey; Lee, Chin Kei; Lo, Janice; Aaskov, John; Ng, Lee Ching; Konings, Frank
2015-01-01
Accurate laboratory testing is a critical component of dengue surveillance and control. The objective of this programme was to assess dengue diagnostic proficiency among national-level public health laboratories in the World Health Organization (WHO) Western Pacific Region. Nineteen national-level public health laboratories performed routine dengue diagnostic assays on a proficiency testing panel consisting of two modules: one containing commercial serum samples spiked with cultured dengue viruses for the detection of nucleic acid and non-structural protein 1 (NS1) (Module A) and one containing human serum samples for the detection of anti-dengue virus antibodies (Module B). A review of logistics arrangements was also conducted. All 16 laboratories testing Module A performed reverse transcriptase polymerase chain reaction (RT-PCR) for both RNA and serotype detection. Of these, 15 had correct results for RNA detection and all 16 correctly serotyped the viruses. All nine laboratories performing NS1 antigen detection obtained the correct results. Sixteen of the 18 laboratories using IgM assays in Module B obtained the correct results as did the 13 laboratories that performed IgG assays. Detection of ongoing/recent dengue virus infection by both molecular (RT-PCR) and serological methods (IgM) was available in 15/19 participating laboratories. This first round of external quality assessment of dengue diagnostics was successfully conducted in national-level public health laboratories in the WHO Western Pacific Region, revealing good proficiency in both molecular and serological testing. Further comprehensive diagnostic testing for dengue virus and other priority pathogens in the Region will be assessed during future rounds.
Molecular diagnostics of periodontitis.
Korona-Głowniak, Izabela; Siwiec, Radosław; Berger, Marcin; Malm, Anna; Szymańska, Jolanta
2017-01-28
The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host's health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridization) come increasingly into use. On the basis of a literature review, the following methods are presented: polymerase chain reaction (PCR), real-time polymerase chain reaction (real-time PCR), 16S rRNA-encoding gene sequencing, checkerboard and reverse-capture checkerboard hybridization, microarrays, denaturing gradient gel electrophoresis (DGGE), temperature gradient gel electrophoresis (TGGE), as well as terminal restriction fragment length polymorphism (TRFLP) and next generation sequencing (NGS). The advantages and drawbacks of each method in the examination of periopathogens are indicated. The techniques listed above allow fast detection of even small quantities of pathogen present in diagnostic material and prove particularly useful to detect microorganisms that are difficult or impossible to grow in a laboratory.
Dixit, Chandra K.; Kadimisetty, Karteek; Otieno, Brunah A.; Tang, Chi; Malla, Spundana; Krause, Colleen E.; Rusling, James F.
2015-01-01
Early detection and reliable diagnostics are keys to effectively design cancer therapies with better prognoses. Simultaneous detection of panels of biomarker proteins holds great promise as a general tool for reliable cancer diagnostics. A major challenge in designing such a panel is to decide upon a coherent group of biomarkers which have higher specificity for a given type of cancer. The second big challenge is to develop test devices to measure these biomarkers quantitatively with high sensitivity and specificity, such that there are no interferences from the complex serum or tissue matrices. Lastly, integrating all these tests into a technology that doesn’t require exclusive training to operate, and can be used at point-of-care (POC) is another potential bottleneck in futuristic cancer diagnostics. In this article, we review electrochemistry-based tools and technologies developed and/or used in our laboratories to construct low-cost microfluidic protein arrays for highly sensitive detection of the panel of cancer-specific biomarkers with high specificity and at the same time have the potential to be translated into a POC. PMID:26525998
Dixit, Chandra K; Kadimisetty, Karteek; Otieno, Brunah A; Tang, Chi; Malla, Spundana; Krause, Colleen E; Rusling, James F
2016-01-21
Early detection and reliable diagnostics are keys to effectively design cancer therapies with better prognoses. The simultaneous detection of panels of biomarker proteins holds great promise as a general tool for reliable cancer diagnostics. A major challenge in designing such a panel is to decide upon a coherent group of biomarkers which have higher specificity for a given type of cancer. The second big challenge is to develop test devices to measure these biomarkers quantitatively with high sensitivity and specificity, such that there are no interferences from the complex serum or tissue matrices. Lastly, integrating all these tests into a technology that does not require exclusive training to operate, and can be used at point-of-care (POC) is another potential bottleneck in futuristic cancer diagnostics. In this article, we review electrochemistry-based tools and technologies developed and/or used in our laboratories to construct low-cost microfluidic protein arrays for the highly sensitive detection of a panel of cancer-specific biomarkers with high specificity which at the same time has the potential to be translated into POC applications.
The role of diagnostic laboratories in support of animal disease surveillance systems.
Zepeda, C
2007-01-01
Diagnostic laboratories are an essential component of animal disease surveillance systems. To understand the occurrence of disease in populations, surveillance systems rely on random or targeted surveys using three approaches: clinical, serological and virological surveillance. Clinical surveillance is the basis for early detection of disease and is usually centered on the detection of syndromes and clinical findings requiring confirmation by diagnostic laboratories. Although most of the tests applied usually perform to an acceptable standard, several have not been properly validated in terms of their diagnostic sensitivity and specificity. Sensitivity and specificity estimates can vary according to local conditions and, ideally, should be determined by national laboratories where the tests are to be applied. The importance of sensitivity and specificity estimates in the design and interpretation of statistically based surveys and risk analysis is fundamental to establish appropriate disease control and prevention strategies. The World Organisation for Animal Health's (OIE) network of reference laboratories acts as centers of expertise for the diagnosis of OIE listed diseases and have a role in promoting the validation of OIE prescribed tests for international trade. This paper discusses the importance of the epidemiological evaluation of diagnostic tests and the role of the OIE Reference Laboratories and Collaborating Centres in this process.
Lacbawan, Felicitas L; Weck, Karen E; Kant, Jeffrey A; Feldman, Gerald L; Schrijver, Iris
2012-01-01
The number of clinical laboratories introducing various molecular tests to their existing test menu is continuously increasing. Prior to offering a US Food and Drug Administration-approved test, it is necessary that performance characteristics of the test, as claimed by the company, are verified before the assay is implemented in a clinical laboratory. To provide an example of the verification of a specific qualitative in vitro diagnostic test: cystic fibrosis carrier testing using the Luminex liquid bead array (Luminex Molecular Diagnostics, Inc, Toronto, Ontario). The approach used by an individual laboratory for verification of a US Food and Drug Administration-approved assay is described. Specific verification data are provided to highlight the stepwise verification approach undertaken by a clinical diagnostic laboratory. Protocols for verification of in vitro diagnostic assays may vary between laboratories. However, all laboratories must verify several specific performance specifications prior to implementation of such assays for clinical use. We provide an example of an approach used for verifying performance of an assay for cystic fibrosis carrier screening.
Spectroscopic diagnostics of organic chemistry in the protostellar environment
NASA Technical Reports Server (NTRS)
Charnley, S. B.; Ehrenfreund, P.; Kuan, Y. J.
2001-01-01
A combination of astronomical observations, laboratory studies, and theoretical modelling is necessary to determine the organic chemistry of dense molecular clouds. We present spectroscopic evidence for the composition and evolution of organic molecules in protostellar environments. The principal reaction pathways to complex molecule formation by catalysis on dust grains and by reactions in the interstellar gas are described. Protostellar cores, where warming of dust has induced evaporation of icy grain mantles, are excellent sites in which to study the interaction between gas phase and grain-surface chemistries. We investigate the link between organics that are observed as direct products of grain surface reactions and those which are formed by secondary gas phase reactions of evaporated surface products. Theory predicts observable correlations between specific interstellar molecules, and also which new organics are viable for detection. We discuss recent infrared observations obtained with the Infrared Space Observatory, laboratory studies of organic molecules, theories of molecule formation, and summarise recent radioastronomical searches for various complex molecules such as ethers, azaheterocyclic compounds, and amino acids.
Pape-Haugaard, Louise; Meltzer, Michelle C; Fuchs, Martin; Schønheyder, Henrik C; Hejlesen, Ole
2016-01-01
Background User mobility is an important aspect of the development of clinical information systems for health care professionals. Mobile phones and tablet computers have obtained widespread use by health care professionals, offering an opportunity for supporting the access to patient information through specialized applications (apps) while supporting the mobility of the users. The use of apps for mobile phones and tablet computers may support workflow of complex tasks, for example, molecular-based diagnostic tests in clinical microbiology. Multiplex Blood Culture Test (MuxBCT) is a molecular-based diagnostic test used for rapid identification of pathogens in positive blood cultures. To facilitate the workflow of the MuxBCT, a specialized tablet computer app was developed as an accessory to the diagnostic test. The app aims to reduce the complexity of the test by step-by-step guidance of microscopy and to assist users in reaching an exact bacterial or fungal diagnosis based on blood specimen observations and controls. Additionally, the app allows for entry of test results, and communication thereof to the laboratory information system (LIS). Objective The objective of the study was to describe the design considerations of the MuxBCT app and the results of a preliminary usability evaluation. Methods The MuxBCT tablet app was developed and set up for use in a clinical microbiology laboratory. A near-live simulation study was conducted in the clinical microbiology laboratory to evaluate the usability of the MuxBCT app. The study was designed to achieve a high degree of realism as participants carried out a scenario representing the context of use for the MuxBCT app. As the MuxBCT was under development, the scenario involved the use of molecular blood culture tests similar to the MuxBCT for identification of microorganisms from positive blood culture samples. The study participants were observed, and their interactions with the app were recorded. After the study, the participants were debriefed to clarify observations. Results Four medical laboratory technicians, for example, representative of end users of the app, participated in the clinical simulation study. Using the MuxBCT app, the study participants successfully identified and reported all microorganisms from the positive blood cultures examined. Three of the four participants reported that they found the app useful, while one study participant reported that she would prefer to make notes on paper and later enter them into the LIS. Conclusions The preliminary usability evaluation results indicate that use of the MuxBCT tablet app can facilitate the workflow of the MuxBCT diagnostic test. PMID:26993432
[Complex diagnostic of cognitive impairment].
Emelin, A Yu; Lobzin, V Yu
2017-01-01
In this article, the authors discussed the various aspects of pre-dementia stages of cognitive impairment, predominantly of neurodegenerative etiology. The modern conception of the pathophysiology of initial stages of cognitive impairment, the potential for lifetime pathological markers of amyloidosis and neurodegeneration are discussed. The authors proposed to use the concept of 'early signs of cognitive impairment'. The algorithm of the complex early diagnosis of cognitive impairment as well as the opportunities and prospects of clinical, neuropsychological, neuroimaging and laboratory examination methods are presented. The data on main diseases characterized by cognitive impairment and prospects for the use of new highly informative methods for early and differential diagnosis of Alzheimer's disease and vascular cognitive impairment are discussed.
A plasma deflagration accelerator as a platform for laboratory astrophysics
NASA Astrophysics Data System (ADS)
Underwood, Thomas C.; Loebner, Keith T. K.; Cappelli, Mark A.
2017-06-01
The replication of astrophysical flows in the laboratory is critical for isolating particular phenomena and dynamics that appear in complex, highly-coupled natural systems. In particular, plasma jets are observed in astrophysical contexts at a variety of scales, typically at high magnetic Reynolds number and driven by internal currents. In this paper, we present detailed measurements of the plasma parameters within deflagration-produced plasma jets, the scaling of these parameters against both machine operating conditions and the corresponding astrophysical phenomena. Using optical and spectroscopic diagnostics, including Schlieren cinematography, we demonstrate the production of current-driven plasma jets of ∼100 km/s and magnetic Reynolds numbers of ∼100, and discuss the dynamics of their acceleration into vacuum. The results of this study will contribute to the reproduction of various types of astrophysical jets in the laboratory and indicate the ability to further probe active research areas such as jet collimation, stability, and interaction.
Manca, Claudia; Hill, Carol; Hujer, Andrea M; Patel, Robin; Evans, Scott R; Bonomo, Robert A; Kreiswirth, Barry N
2017-03-15
The Antibacterial Resistance Leadership Group (ARLG) Laboratory Center (LC) leads the evaluation, development, and implementation of laboratory-based research by providing scientific leadership and supporting standard/specialized laboratory services. The LC has developed a physical biorepository and a virtual biorepository. The physical biorepository contains bacterial isolates from ARLG-funded studies located in a centralized laboratory and they are available to ARLG investigators. The Web-based virtual biorepository strain catalogue includes well-characterized gram-positive and gram-negative bacterial strains published by ARLG investigators. The LC, in collaboration with the ARLG Leadership and Operations Center, developed procedures for review and approval of strain requests, guidance during the selection process, and for shipping strains from the distributing laboratories to the requesting investigators. ARLG strains and scientific and/or technical guidance have been provided to basic research laboratories and diagnostic companies for research and development, facilitating collaboration between diagnostic companies and the ARLG Master Protocol for Evaluating Multiple Infection Diagnostics (MASTERMIND) initiative for evaluation of multiple diagnostic devices from a single patient sampling event. In addition, the LC has completed several laboratory-based studies designed to help evaluate new rapid molecular diagnostics by developing, testing, and applying a MASTERMIND approach using purified bacterial strains. In collaboration with the ARLG's Statistical and Data Management Center (SDMC), the LC has developed novel analytical strategies that integrate microbiologic and genetic data for improved and accurate identification of antimicrobial resistance. These novel approaches will aid in the design of future ARLG studies and help correlate pathogenic markers with clinical outcomes. The LC's accomplishments are the result of a successful collaboration with the ARLG's Leadership and Operations Center, Diagnostics and Devices Committee, and SDMC. This interactive approach has been pivotal for the success of LC projects. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Ambrose, H. E.; Granerod, J.; Clewley, J. P.; Davies, N. W. S.; Keir, G.; Cunningham, R.; Zuckerman, M.; Mutton, K. J.; Ward, K. N.; Ijaz, S.; Crowcroft, N. S.; Brown, D. W. G.
2011-01-01
The laboratory diagnostic strategy used to determine the etiology of encephalitis in 203 patients is reported. An etiological diagnosis was made by first-line laboratory testing for 111 (55%) patients. Subsequent testing, based on individual case reviews, resulted in 17 (8%) further diagnoses, of which 12 (71%) were immune-mediated and 5 (29%) were due to infection. Seventy-five cases were of unknown etiology. Sixteen (8%) of 203 samples were found to be associated with either N-methyl-d-aspartate receptor or voltage-gated potassium channel complex antibodies. The most common viral causes identified were herpes simplex virus (HSV) (19%) and varicella-zoster virus (5%), while the most important bacterial cause was Mycobacterium tuberculosis (5%). The diagnostic value of testing cerebrospinal fluid (CSF) for antibody was assessed using 139 samples from 99 patients, and antibody was detected in 46 samples from 37 patients. Samples collected at 14 to 28 days were more likely to be positive than samples taken 0 to 6 days postadmission. Three PCR-negative HSV cases were diagnosed by the presence of virus-specific antibody in the central nervous system (CNS). It was not possible to make an etiological diagnosis for one-third of the cases; these were therefore considered to be due to unknown causes. Delayed sampling did not contribute to these cases. Twenty percent of the patients with infections with an unknown etiology showed evidence of localized immune activation within the CNS, but no novel viral DNA or RNA sequences were found. We conclude that a good standard of clinical investigation and thorough first-line laboratory testing allows the diagnosis of most cases of infectious encephalitis; testing for CSF antibodies allows further cases to be diagnosed. It is important that testing for immune-mediated causes also be included in a diagnostic algorithm. PMID:21865429
Targeted Re-Sequencing Emulsion PCR Panel for Myopathies: Results in 94 Cases.
Punetha, Jaya; Kesari, Akanchha; Uapinyoying, Prech; Giri, Mamta; Clarke, Nigel F; Waddell, Leigh B; North, Kathryn N; Ghaoui, Roula; O'Grady, Gina L; Oates, Emily C; Sandaradura, Sarah A; Bönnemann, Carsten G; Donkervoort, Sandra; Plotz, Paul H; Smith, Edward C; Tesi-Rocha, Carolina; Bertorini, Tulio E; Tarnopolsky, Mark A; Reitter, Bernd; Hausmanowa-Petrusewicz, Irena; Hoffman, Eric P
2016-05-27
Molecular diagnostics in the genetic myopathies often requires testing of the largest and most complex transcript units in the human genome (DMD, TTN, NEB). Iteratively targeting single genes for sequencing has traditionally entailed high costs and long turnaround times. Exome sequencing has begun to supplant single targeted genes, but there are concerns regarding coverage and needed depth of the very large and complex genes that frequently cause myopathies. To evaluate efficiency of next-generation sequencing technologies to provide molecular diagnostics for patients with previously undiagnosed myopathies. We tested a targeted re-sequencing approach, using a 45 gene emulsion PCR myopathy panel, with subsequent sequencing on the Illumina platform in 94 undiagnosed patients. We compared the targeted re-sequencing approach to exome sequencing for 10 of these patients studied. We detected likely pathogenic mutations in 33 out of 94 patients with a molecular diagnostic rate of approximately 35%. The remaining patients showed variants of unknown significance (35/94 patients) or no mutations detected in the 45 genes tested (26/94 patients). Mutation detection rates for targeted re-sequencing vs. whole exome were similar in both methods; however exome sequencing showed better distribution of reads and fewer exon dropouts. Given that costs of highly parallel re-sequencing and whole exome sequencing are similar, and that exome sequencing now takes considerably less laboratory processing time than targeted re-sequencing, we recommend exome sequencing as the standard approach for molecular diagnostics of myopathies.
Suhanic, West; Crandall, Ian; Pennefather, Peter
2009-07-17
Deficits in clinical microbiology infrastructure exacerbate global infectious disease burdens. This paper examines how commodity computation, communication, and measurement products combined with open-source analysis and communication applications can be incorporated into laboratory medicine microbiology protocols. Those commodity components are all now sourceable globally. An informatics model is presented for guiding the use of low-cost commodity components and free software in the assembly of clinically useful and usable telemicrobiology workstations. The model incorporates two general principles: 1) collaborative diagnostics, where free and open communication and networking applications are used to link distributed collaborators for reciprocal assistance in organizing and interpreting digital diagnostic data; and 2) commodity engineering, which leverages globally available consumer electronics and open-source informatics applications, to build generic open systems that measure needed information in ways substantially equivalent to more complex proprietary systems. Routine microscopic examination of Giemsa and fluorescently stained blood smears for diagnosing malaria is used as an example to validate the model. The model is used as a constraint-based guide for the design, assembly, and testing of a functioning, open, and commoditized telemicroscopy system that supports distributed acquisition, exploration, analysis, interpretation, and reporting of digital microscopy images of stained malarial blood smears while also supporting remote diagnostic tracking, quality assessment and diagnostic process development. The open telemicroscopy workstation design and use-process described here can address clinical microbiology infrastructure deficits in an economically sound and sustainable manner. It can boost capacity to deal with comprehensive measurement of disease and care outcomes in individuals and groups in a distributed and collaborative fashion. The workstation enables local control over the creation and use of diagnostic data, while allowing for remote collaborative support of diagnostic data interpretation and tracking. It can enable global pooling of malaria disease information and the development of open, participatory, and adaptable laboratory medicine practices. The informatic model highlights how the larger issue of access to generic commoditized measurement, information processing, and communication technology in both high- and low-income countries can enable diagnostic services that are much less expensive, but substantially equivalent to those currently in use in high-income countries.
Alirol, Emilie; Horie, Ninon Seiko; Barbé, Barbara; Lejon, Veerle; Verdonck, Kristien; Gillet, Philippe; Jacobs, Jan; Büscher, Philippe; Kanal, Basudha; Bhattarai, Narayan Raj; El Safi, Sayda; Phe, Thong; Lim, Kruy; Leng, Long; Lutumba, Pascal; Mukendi, Deby; Bottieau, Emmanuel; Boelaert, Marleen; Rijal, Suman; Chappuis, François
2016-11-01
In resource-limited settings, the scarcity of skilled personnel and adequate laboratory facilities makes the differential diagnosis of fevers complex [1-5]. Febrile illnesses are diagnosed clinically in most rural centers, and both Rapid Diagnostic Tests (RDTs) and clinical algorithms can be valuable aids to health workers and facilitate therapeutic decisions [6,7]. The persistent fever syndrome targeted by NIDIAG is defined as presence of fever for at least one week. The NIDIAG clinical research consortium focused on potentially severe and treatable infections and therefore targeted the following conditions as differential diagnosis of persistent fever: visceral leishmaniasis (VL), human African trypanosomiasis (HAT), enteric (typhoid and paratyphoid) fever, brucellosis, melioidosis, leptospirosis, malaria, tuberculosis, amoebic liver abscess, relapsing fever, HIV/AIDS, rickettsiosis, and other infectious diseases (e.g., pneumonia). From January 2013 to October 2014, a prospective clinical phase III diagnostic accuracy study was conducted in one site in Cambodia, two sites in Nepal, two sites in Democratic Republic of the Congo (DRC), and one site in Sudan (clinicaltrials.gov no. NCT01766830). The study objectives were to (1) determine the prevalence of the target diseases in patients presenting with persistent fever, (2) assess the predictive value of clinical and first-line laboratory features, and (3) assess the diagnostic accuracy of several RDTs for the diagnosis of the different target conditions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false User fees for other veterinary... FEES USER FEES § 130.17 User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or at authorized sites. (a) User fees for veterinary diagnostics tests performed at the...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for other veterinary... FEES USER FEES § 130.17 User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or at authorized sites. (a) User fees for veterinary diagnostics tests performed at the...
Multiplex method for initial complex testing of antibodies to blood transmitted diseases agents.
Poltavchenko, Alexander G; Nechitaylo, Oleg V; Filatov, Pavel V; Ersh, Anna V; Gureyev, Vadim N
2016-10-01
Initial screening of donors and population at high risk of infection with blood transmitted diseases involves a number of analyses using monospesific diagnostic systems, and therefore is expensive labor- and time-consuming process. The goal of this work is to construct a multiplex test enabling to carry out rapid initial complex testing at a low price. The paper describes a kit making it possible to detect simultaneously antibodies to six agents of the most significant blood transmitted diseases: HIV virus, hepatitis B and C viruses, cytomegalovirus, T. pallidum and T. gondii in blood products. The kit comprises multiplex dot-immunoassay based on plane protein arrays (immune chips) using colloidal gold conjugates and silver development. It provides an opportunity to carry out complex analysis within 70min at room temperature, and there is no need of well-qualified personnel. We compared laboratory findings of the kit with monospecific kits for ELISA produced by two Russian commercial companies. Dot-assay results correlate well with data obtained using commercial kits for ELISA. Furthermore, multiplex analysis is quicker and cheaper in comparison with ELISA and can be carried out in non-laboratory conditions. The kit for multiplex dot-immunoassay of antibodies to blood transmitted agents can significantly simplify initial complex testing. Copyright © 2016 Elsevier B.V. All rights reserved.
Rapid molecular assays for detection of tuberculosis.
Eddabra, Rkia; Ait Benhassou, Hassan
2018-01-01
Tuberculosis (TB) is an infectious disease that remains an important public health problem at the global level. It is one of the main causes of morbidity and mortality, due to the emergence of antibiotic resistant Mycobacterium strains and HIV co-infection. Over the past decade, important progress has been made for better control of the disease. While microscopy and culture continue to be indispensible for laboratory diagnosis of tuberculosis, the range of several molecular diagnostic tests, including the nucleic acid amplification test (NAAT) and whole-genome sequencing (WGS), have expanded tremendously. They are becoming more accessible not only for detection and identification of Mycobacterium tuberculosis complex in clinical specimens, but now extend to diagnosing multi-drug resistant strains. Molecular diagnostic tests provide timely results useful for high-quality patient care, low contamination risk, and ease of performance and speed. This review focuses on the current diagnostic tests in use, including emerging technologies used for detection of tuberculosis in clinical specimens. The sensitivity and specificity of these tests have also been taken into consideration.
NAIMA as a solution for future GMO diagnostics challenges.
Dobnik, David; Morisset, Dany; Gruden, Kristina
2010-03-01
In the field of genetically modified organism (GMO) diagnostics, real-time PCR has been the method of choice for target detection and quantification in most laboratories. Despite its numerous advantages, however, the lack of a true multiplexing option may render real-time PCR less practical in the face of future GMO detection challenges such as the multiplicity and increasing complexity of new transgenic events, as well as the repeated occurrence of unauthorized GMOs on the market. In this context, we recently reported the development of a novel multiplex quantitative DNA-based target amplification method, named NASBA implemented microarray analysis (NAIMA), which is suitable for sensitive, specific and quantitative detection of GMOs on a microarray. In this article, the performance of NAIMA is compared with that of real-time PCR, the focus being their performances in view of the upcoming challenge to detect/quantify an increasing number of possible GMOs at a sustainable cost and affordable staff effort. Finally, we present our conclusions concerning the applicability of NAIMA for future use in GMO diagnostics.
Laboratory activities involving transmissible spongiform encephalopathy causing agents
Leunda, Amaya; Van Vaerenbergh, Bernadette; Baldo, Aline; Roels, Stefan; Herman, Philippe
2013-01-01
Since the appearance in 1986 of epidemic of bovine spongiform encephalopathy (BSE), a new form of neurological disease in cattle which also affected human beings, many diagnostic and research activities have been performed to develop detection and therapeutic tools. A lot of progress was made in better identifying, understanding and controlling the spread of the disease by appropriate monitoring and control programs in European countries. This paper reviews the recent knowledge on pathogenesis, transmission and persistence outside the host of prion, the causative agent of transmissible spongiform encephalopathies (TSE) in mammals with a particular focus on risk (re)assessment and management of biosafety measures to be implemented in diagnostic and research laboratories in Belgium. Also, in response to the need of an increasing number of European diagnostic laboratories stopping TSE diagnosis due to a decreasing number of TSE cases reported in the last years, decontamination procedures and a protocol for decommissioning TSE diagnostic laboratories is proposed. PMID:24055928
van Asten, Liselotte; van der Lubben, Mariken; van den Wijngaard, Cees; van Pelt, Wilfrid; Verheij, Robert; Jacobi, Andre; Overduin, Pieter; Meijer, Adam; Luijt, Dirk; Claas, Eric; Hermans, Mirjam; Melchers, Willem; Rossen, John; Schuurman, Rob; Wolffs, Petra; Boucher, Charles; Bouchier, Charles; Schirm, Jurjen; Kroes, Louis; Leenders, Sander; Galama, Joep; Peeters, Marcel; van Loon, Anton; Stobberingh, Ellen; Schutten, Martin; Koopmans, Marion
2009-07-01
Experience with a highly pathogenic avian influenza outbreak in the Netherlands (2003) illustrated that the diagnostic demand for respiratory viruses at different biosafety levels (including BSL3), can increase unexpectedly and dramatically. We describe the measures taken since, aimed at strengthening national laboratory surge capacity and improving preparedness for dealing with diagnostic demand during outbreaks of (emerging) respiratory virus infections, including pandemic influenza virus. Academic and peripheral medical-microbiological laboratories collaborated to determine minimal laboratory requirements for the identification of viruses in the early stages of a pandemic or a large outbreak of avian influenza virus. Next, an enhanced collaborative national network of outbreak assistance laboratories (OAL) was set up. An inventory was made of the maximum diagnostic throughput that this network can deliver in a period of intensified demand. For an estimate of the potential magnitude of this surge demand, historical counts were calculated from hospital- and physician-based registries of patients presenting with respiratory symptoms. Number of respiratory physician-visits ranged from 140,000 to 615,000 per month and hospitalizations ranged from 3000 to 11,500 per month. The established OAL-network provides rapid diagnostic response with agreed quality requirements and a maximum throughput capacity of 1275 samples/day (38,000 per month), assuming other routine diagnostic work needs to be maintained. Thus surge demand for diagnostics for hospitalized cases (if not distinguishable from other respiratory illness) could be handled by the OAL network. Assessing etiology of community acquired acute respiratory infection however, may rapidly exceed the capacity of the network. Therefore algorithms are needed for triaging for laboratory diagnostics; currently this is not addressed in pandemic preparedness plans.
Brzozowski, Amanda K; Silk, Benjamin J; Berkelman, Ruth L; Loveys, Deborah A; Caliendo, Angela M
2012-01-01
Although clinical microbiology testing facilitates both public health surveillance of infectious diseases and patient care, research on testing patterns is scant. We surveyed hospital laboratories in Georgia to assess their diagnostic testing practices. Using e-mail, all directors of hospital laboratories in Georgia were invited to participate. The survey focused on timing and location of diagnostic testing in 2006 for 6 reportable diseases: giardiasis, legionellosis, meningococcal disease, pertussis, Rocky Mountain spotted fever, and West Nile virus disease. Of 141 laboratories, 62 (44%) responded to the survey. Hospitals varied widely in their use of diagnostic testing in 2006, with 95.1% testing for meningococcal disease, but only 66.1% and 63.3% testing for legionellosis and West Nile virus disease, respectively. Most laboratories (91%) performed gram stain/culture to diagnose meningococcal disease in-house and 23% performed ova and parasite panels for giardiasis were conducted in-house. Fewer than 11% of laboratories performed in-house testing for the remaining diseases. Laboratories affiliated with small hospitals (≤100 beds) were more likely to send specimens for outside testing compared with laboratories associated with large hospitals (>250 beds). Median turnaround time for ova and parasite panel testing for giardiasis was significantly shorter for in-house testing (1.0 days) than within-system (2.25 days) or outside laboratory (3.0 days) testing (P = .0003). No laboratories reported in-house testing for meningococcal disease, pertussis, or Rocky Mountain spotted fever using polymerase chain reaction. Many hospitals did not order diagnostic tests for important infectious diseases during 2006, even for relatively common diseases. In addition, hospital laboratories were unlikely to perform diagnostic testing in-house; sending specimens to an outside laboratory may result in substantial delays in receiving results. These unsettling findings have adverse implications for both patient care and public health surveillance; they indicate an immediate need to study nationally the use and timeliness of clinical microbiologic testing.
Assessment of biosafety precautions in Khartoum state diagnostic laboratories, Sudan.
Elduma, Adel Hussein
2012-01-01
This study was conducted to evaluate the biosafety precautions that applied by diagnostic laboratories in Khartoum state, 2009. A total number of 190 laboratories were surveyed about their compliance with standard biosafety precautions. These laboratories included 51 (27%) laboratories from government, 75 (39%) from private sectors and 64 (34%) laboratories belong to organization providing health care services. The study found that 32 (16.8%) of laboratories appointed biosafety officers. Only, ten (5.2%) participated in training about response to fire emergency, and 28 (14.7%) reported the laboratory accident occurred during work. 45 (23.7%) laboratories had a written standard operation procedures (SOPs), and 35 (18.4%) had written procedures for the lean-up of spills. Moreover, biosafety cabinet was found in 11 (5.8%) laboratories, autoclave in 28 (14.7%) and incinerator in only two (1.1%) laboratories. Sharp disposable containers were found in 84 (44.2%). Fire alarm system was found in 2 (1.1%) laboratories, fire extinguisher in 39 (20.5%) laboratories, and fire emergency exit found in 14 (7.4%) laboratories. Furthermore, 19 (10%) laboratories had a hepatitis B virus vaccination programme, 5 (6.2%) applied BCG vaccine, and 2 (1.1%0) vaccinated the staff against influenza. The study concluded that the standards biosafety precautions adopted by the diagnostic laboratories in Khartoum state was very low. Further, the laboratory personnel awareness towards biosafety principles implementation was very low too.
Truszczyński, M J
1998-08-01
Veterinary laboratories which deal with infectious diseases form three groups according to the tasks for which they are responsible. The first group includes central or national veterinary laboratories, national or international reference laboratories, high-security laboratories, district regional or state veterinary diagnostic laboratories. The major role of these laboratories is to assist national Veterinary Services in diagnosing infectious animal diseases. The second group comprises laboratories that produce veterinary diagnostic kits and those that produce veterinary vaccines. The third group is composed of veterinary research laboratories, which generally concentrate on basic research and do not contribute directly to the diagnosis and control of infectious animal diseases. The author describes the objectives of each of the three groups of laboratories.
Laboratory automation in clinical bacteriology: what system to choose?
Croxatto, A; Prod'hom, G; Faverjon, F; Rochais, Y; Greub, G
2016-03-01
Automation was introduced many years ago in several diagnostic disciplines such as chemistry, haematology and molecular biology. The first laboratory automation system for clinical bacteriology was released in 2006, and it rapidly proved its value by increasing productivity, allowing a continuous increase in sample volumes despite limited budgets and personnel shortages. Today, two major manufacturers, BD Kiestra and Copan, are commercializing partial or complete laboratory automation systems for bacteriology. The laboratory automation systems are rapidly evolving to provide improved hardware and software solutions to optimize laboratory efficiency. However, the complex parameters of the laboratory and automation systems must be considered to determine the best system for each given laboratory. We address several topics on laboratory automation that may help clinical bacteriologists to understand the particularities and operative modalities of the different systems. We present (a) a comparison of the engineering and technical features of the various elements composing the two different automated systems currently available, (b) the system workflows of partial and complete laboratory automation, which define the basis for laboratory reorganization required to optimize system efficiency, (c) the concept of digital imaging and telebacteriology, (d) the connectivity of laboratory automation to the laboratory information system, (e) the general advantages and disadvantages as well as the expected impacts provided by laboratory automation and (f) the laboratory data required to conduct a workflow assessment to determine the best configuration of an automated system for the laboratory activities and specificities. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Laboratory diagnostics of chronic kidney disease in Croatia: state of the art
Honović, Lorena; Matica, Jasminka; Knežević, Branka; Vojak, Sanela Šimić
2015-01-01
Introduction Early identification and management of chronic kidney disease (CKD) is highly cost-effective and can reduce the risk of kidney failure progression and cardiovascular disease. In 2014, the Joint Croatian Working Group (JCWG) for laboratory diagnostic of CKD on the behalf of Croatian society of medical biochemistry and laboratory medicine (CSMBLM) and Croatian chamber of medical biochemists (CCMB) conducted a survey across Croatian medical-biochemistry laboratories to assess the current practice in this area of laboratory medicine. The aim of this study was to present the data collected through the survey and to give insight about laboratory diagnostics of chronic kidney disease in Croatia. Materials and methods An invitation to participate in the survey was sent to all Croatian medical-biochemistry laboratories (N = 196). The questionnaire was designed in a form of questions and statements, with possible multiple answers, comprising 24 questions. Results The response rate was 80/196 (40.8%). 39 answers were from primary medical-biochemistry laboratories. 31/78 (0.40) laboratories measure creatinine with non-standardized method (uncompensated Jaffe method). 58/78 (0.74) of laboratories that measure creatinine do not report eGFR values. Similar number of laboratories (58/80, 0.73) do not measure urine albumin or protein. Conclusions There is a large heterogeneity among Croatian laboratories regarding measuring methods, reporting units and reference intervals (cut-off values), both for creatinine and urine albumin or protein. The two key prerequisites for CKD screening, automatic reporting of eGFR and albuminuria or proteinuria assessment, are not implemented nationwide. There is a need for harmonization in laboratory diagnostics of CKD in Croatia. PMID:25672470
Alexander, C L; Currie, S; Pollock, K; Smith-Palmer, A; Jones, B L
2017-06-01
Giardia duodenalis and Cryptosporidium species are protozoan parasites capable of causing gastrointestinal disease in humans and animals through the ingestion of infective faeces. Whereas Cryptosporidium species can be acquired locally or through foreign travel, there is the mis-conception that giardiasis is considered to be largely travel-associated, which results in differences in laboratory testing algorithms. In order to determine the level of variation in testing criteria and detection methods between diagnostic laboratories for both pathogens across Scotland, an audit was performed. Twenty Scottish diagnostic microbiology laboratories were invited to participate with questions on sample acceptance criteria, testing methods, testing rates and future plans for pathogen detection. Reponses were received from 19 of the 20 laboratories representing each of the 14 territorial Health Boards. Detection methods varied between laboratories with the majority performing microscopy, one using a lateral flow immunochromatographic antigen assay, another using a manually washed plate-based enzyme immunoassay (EIA) and one laboratory trialling a plate-based EIA automated with an EIA plate washer. Whereas all laboratories except one screened every stool for Cryptosporidium species, an important finding was that significant variation in the testing algorithm for detecting Giardia was noted with only four laboratories testing all diagnostic stools. The most common criteria were 'travel history' (11 laboratories) and/or 'when requested' (14 laboratories). Despite only a small proportion of stools being examined in 15 laboratories for Giardia (2%-18% of the total number of stools submitted), of interest is the finding that a higher positivity rate was observed for Giardia than Cryptosporidium in 10 of these 15 laboratories. These findings highlight that the underreporting of Giardia in Scotland is likely based on current selection and testing algorithms.
District, state or regional veterinary diagnostic laboratories.
Gosser, H S; Morehouse, L G
1998-08-01
The district, regional or state laboratory is the local laboratory to which veterinarian practitioners usually submit samples, and consequently these laboratories are usually the first to observe a suspected disease problem. In most countries, these laboratories are under the jurisdiction of the State or region in which they are located. In the United States of America (USA), most veterinary diagnostic laboratories are State-associated and operate under the aegis of either the State Department of Agriculture or a university. The national laboratory provides reference assistance to the State laboratories. In the USA, the national Laboratory (the National Veterinary Services Laboratories) acts as a consultant to confirm difficult diagnoses and administer performance tests for State-associated laboratories. District, state or regional laboratories need to share information regarding technological advances in diagnostic procedures. This need was met in the USA by the formation of the American Association of Veterinary Laboratory Diagnosticians (AAVLD) in the late 1950s. Another requirement of district, state or regional diagnostic laboratories is a method to confirm quality assurance, which was fulfilled in the USA by an accreditation programme established through the AAVLD. The Accreditation Committee evaluates laboratories (on request) in terms of organisation, personnel, physical facilities and equipment, records, finance and budget. Those laboratories which meet the standards as established in the 'Essential Requirements for Accreditation' are given accreditation status, which indicates that they have the expertise and facilities to perform tests on food-producing animals for shipment in national or international commerce and on companion, laboratory or zoo animals. While confidentiality of test records is most important, it is becoming necessary to release certain types of animal disease test information if a country is to participate in the exportation of animals and animal products. As district, state and regional laboratories operate under many different administrative entities (i.e., universities, State governments and the Federal government), various checks at different administrative levels provide safeguards and reduce the possibility of faulty disease reporting.
Sá, Luísa; Teixeira, Andreia Sofia Costa; Tavares, Fernando; Costa-Santos, Cristina; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto Pinto; Santos, Paulo
2017-01-01
Objectives To characterise the test ordering pattern in Northern Portugal and to investigate the influence of context-related factors, analysing the test ordered at the level of geographical groups of family physicians and at the level of different healthcare organisations. Design Cross-sectional study. Setting Northern Primary Health Care, Portugal. Participants Records about diagnostic and laboratory tests ordered from 2035 family physicians working at the Northern Regional Health Administration, who served approximately 3.5 million Portuguese patients, in 2014. Outcomes To determine the 20 most ordered diagnostic and laboratory tests in the Northern Regional Health Administration; to identify the presence and extent of variations in the 20 most ordered diagnostic and laboratory tests between the Groups of Primary Care Centres and between health units; and to study factors that may explain these variations. Results The 20 most ordered diagnostic and laboratory tests almost entirely comprise laboratory tests and account for 70.9% of the total tests requested. We can trace a major pattern of test ordering for haemogram, glucose, lipid profile, creatinine and urinalysis. There was a significant difference (P<0.001) in test orders for all tests between Groups of Primary Care Centres and for all tests, except glycated haemoglobin (P=0.06), between health units. Generally, the Personalised Healthcare Units ordered more than Family Health Units. Conclusions The results from this study show that the most commonly ordered tests in Portugal are laboratory tests, that there is a tendency for overtesting and that there is a large variability in diagnostic and laboratory test ordering in different geographical and organisational Portuguese primary care practices, suggesting that there may be considerable potential for the rationalisation of test ordering. The existence of Family Health Units seems to be a strong determinant in decreasing test ordering by Portuguese family physicians. Approaches to ensuring more rational testing are needed. PMID:29146654
Hölzel, W; Baumgarten, R; Fiedler, H; Zimmermann, S
1985-12-01
The optimal utilization of the knowledge and possibilities of pathological and clinical biochemistry presumes a close cooperation between it and the clinical specialties. The common working team of the GDR Society of Internal Medicine and the GDR Society for Clinical Chemistry and Laboratory Diagnostics makes theses of the central points of the cooperation in care, education, further education and postgraduate study and in research a subject for discussion. As essential tasks in the process of medical care are regarded the balance of the examination programme standing at the disposal, the establishment of diagnostic programmes, the establishment of organisational measures, the ascertainment of a use according to indication, the guarantee of the representance of examination material, the control of plausibility and the interpretation of test results. Since the realization of the tasks to a large extent depends on the cooperation of the specialities in education, further education and postgraduate study during the further education the clinician should become acquainted with the possibilities, the limits and the prerequisites for the performance of laboratory diagnostic investigations, the clinical biochemist with the problems of medical care and the value of the laboratory diagnosis in the total process of the treatment. In the field of research the result is a necessary cooperation in the clarification of patho-biochemical mechanisms, in the search for suitable laboratory diagnostic parameters for diagnostics and control of the course as well as in the statement of the validity of laboratory diagnostic parameters and parameter combinations taking into consideration the factors expenses, benefit and risk as well as further diagnostic possibilities.
Implementation of HIV and Tuberculosis Diagnostics: The Importance of Context
Dominique, Joyelle K.; Ortiz-Osorno, Alberto A.; Fitzgibbon, Joseph; Gnanashanmugam, Devasena; Gilpin, Christopher; Tucker, Timothy; Peel, Sheila; Peter, Trevor; Kim, Peter; Smith, Steven
2015-01-01
Background. Novel diagnostics have been widely applied across human immunodeficiency virus (HIV) and tuberculosis prevention and treatment programs. To achieve the greatest impact, HIV and tuberculosis diagnostic programs must carefully plan and implement within the context of a specific healthcare system and the laboratory capacity. Methods. A workshop was convened in Cape Town in September 2014. Participants included experts from laboratory and clinical practices, officials from ministries of health, and representatives from industry. Results. The article summarizes best practices, challenges, and lessons learned from implementation experiences across sub-Saharan Africa for (1) building laboratory programs within the context of a healthcare system; (2) utilizing experience of clinicians and healthcare partners in planning and implementing the right diagnostic; and (3) evaluating the effects of new diagnostics on the healthcare system and on patient health outcomes. Conclusions. The successful implementation of HIV and tuberculosis diagnostics in resource-limited settings relies on careful consideration of each specific context. PMID:26409272
Laser micromachining of biofactory-on-a-chip devices
NASA Astrophysics Data System (ADS)
Burt, Julian P.; Goater, Andrew D.; Hayden, Christopher J.; Tame, John A.
2002-06-01
Excimer laser micromachining provides a flexible means for the manufacture and rapid prototyping of miniaturized systems such as Biofactory-on-a-Chip devices. Biofactories are miniaturized diagnostic devices capable of characterizing, manipulating, separating and sorting suspension of particles such as biological cells. Such systems operate by exploiting the electrical properties of microparticles and controlling particle movement in AC non- uniform stationary and moving electric fields. Applications of Biofactory devices are diverse and include, among others, the healthcare, pharmaceutical, chemical processing, environmental monitoring and food diagnostic markets. To achieve such characterization and separation, Biofactory devices employ laboratory-on-a-chip type components such as complex multilayer microelectrode arrays, microfluidic channels, manifold systems and on-chip detection systems. Here we discuss the manufacturing requirements of Biofactory devices and describe the use of different excimer laser micromachined methods both in stand-alone processes and also in conjunction with conventional fabrication processes such as photolithography and thermal molding. Particular attention is given to the production of large area multilayer microelectrode arrays and the manufacture of complex cross-section microfluidic channel systems for use in simple distribution and device interfacing.
Lillis, Lorraine; Lehman, Dara A.; Siverson, Joshua B.; Weis, Julie; Cantera, Jason; Parker, Mathew; Piepenburg, Olaf; Overbaugh, Julie; Boyle, David S.
2016-01-01
A low complexity diagnostic test that rapidly and reliably detects HIV infection in infants at the point of care could facilitate early treatment, improving outcomes. However, many infant HIV diagnostics can only be performed in laboratory settings. Recombinase polymerase amplification (RPA) is an isothermal amplification technology that can rapidly amplify proviral DNA from multiple subtypes of HIV-1 in under twenty minutes without complex equipment. In this study we added reverse transcription (RT) to RPA to allow detection of both HIV-1 RNA and DNA. We show that this RT-RPA HIV-1 assay has a limit of detection of 10 to 30 copies of an exact sequence matched DNA or RNA, respectively. In addition, at 100 copies of RNA or DNA, the assay detected 171 of 175 (97.7 %) sequence variants that represent all the major subtypes and recombinant forms of HIV-1 Groups M and O. This data suggests that the application of RT-RPA for the combined detection of HIV-1 viral RNA and proviral DNA may prove a highly sensitive tool for rapid and accurate diagnosis of infant HIV. PMID:26821087
Lippi, Giuseppe; Plebani, Mario; Favaloro, Emmanuel J
2015-04-01
The reality of laboratory diagnostics as a whole, and hemostasis testing in particular, is evolving under new paradigms of efficiency. The driving forces of health care and laboratory diagnostics in the third millennium are mainly represented by macro- and microeconomics. In a world with limited resources, shattered by an unprecedented economic crisis, laboratory diagnostics is undergoing a substantial reorganization, with emergence of new models under the imperative of terms, such as bedside testing, consolidation, and networking. The paradigms under which these changes are being developed include a variety of environment, preanalytical, technological, professional, and health-care aspects. The maintenance of continued quality is indeed the major challenge to be faced in the foreseeable future. In fact, some challenges prepotently emerge during a consolidation process, which basically involve delayed testing, centrifugation, transportation, and stability of the specimens, as well as the potential mismatch of sample matrix. This article is aimed to provide an overview of the current economic scenario of laboratory diagnostics and discuss the changing face of hemostasis testing in modern laboratories, providing a synthetic overview about potential drawbacks of actualized solutions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Onishenko, G G; Popova, A Iu; Bragina, I V; Kuz'kin, B P; Ezhlova, E B; Demina, Iu V; Gus'kov, A S; Ivanov, G E; Chikina, L V; Klindukhova, V P; Grechanaia, T V; Tesheva, S Ch; Kulichenko, A N; Efremenko, D B; Manin, E A; Kuznetsova, I V; Parkhomenko, V V; Kulichenko, O A; Rafeenko, G K; Shcherbina, L I; Zavora, D L; Briukhanov, A F; Eldinova, V E; Iunicheva, Iu V; Derliatko, S K; Komarov, N S
2015-01-01
The experience of the organization and functioning of the laboratory network during the XXII Olympic Winter Games and XI Paralympic Winter Games of 2014 in Sochi is considered. Efforts to establish an effective system of laboratory support, the order of work and interaction of diagnostic laboratories involved in diseases control of population during the Olympic Games are analyzed.
Readership survey. A big welcome for Diagnostics in Africa.
Chinnock, P
1994-09-01
Targeted to physicians, Africa Health is circulated free to 5600 readers in 23 African countries. Diagnostics in Africa (DIA) is a young publication included as a supplement of Africa Health aimed at laboratory personnel. Readers of DIA were surveyed in the first two issues to find out what they thought of the supplement, how it could be improved, and which problems they currently faced in their work. 98 questionnaires were returned from twelve African countries. 46% of respondents were qualified in laboratory science and 41% were physicians; the others were unqualified laboratory staff and other medical personnel. 73% responded that DIA was very useful and 27% useful, with 80% finding the articles of appropriate depth and complexity. Respondents would like to read about clinical chemistry, histopathology/histology, immunology, management issues, serology, and education/professional development, and would particularly enjoy material in the form of readers' letters and quizzes. Readers responded variously that they were regularly exposed to either Medicine Digest, Dialogue on Diarrhea, Postgraduate Doctor, Labmedica, Lancet, International Diabetes Digest, New England Journal of Medicine, British Medical Journal, or ARI News. Problems typically faced in their work include lack of resources, problems related to HIV testing/screening, poor access to literature, problems with professional development, and difficulty understanding the theory and practice of Western blot tests. These findings confirm assessments of the situation in Africa's medical labs which led to the launching of DIA.
Robinson, P A; Epperson, W B
2013-05-11
Diagnostic sampling of farm animals by private veterinary practitioners can be an important contributing factor towards the discovery of emerging and exotic diseases. This focus group study of farm animal practitioners in Northern Ireland investigated their use and expectations of diagnostic veterinary laboratories, and elicited their opinions on the role of the private practitioner in veterinary surveillance and the protection of rural public health. The veterinarians were enthusiastic users of diagnostic laboratories, and regarded their own role in surveillance as pivotal. They attached great importance to their veterinary public health duties, and called for more collaboration with their medical general practitioner counterparts. The findings of this research can be used to guide future development of veterinary diagnostic services; provide further insights into the mechanics of scanning surveillance; and measure progress towards a 'One Health' approach between veterinarians and physicians in one geographical region of the UK.
Djangirova, T V; Shabalova, I P; Pronichev, A N; Polyakov, E V
2015-08-01
The article considers application of technology of analysis of cytological slides in external quality control of clinical diagnostic laboratories. The advantages of virtual slides are demonstrated against other applied technologies of external evaluation of quality i.e. slide plate and digital micro-photography. The conditions of formation of virtual slides for external evaluation of quality of clinical diagnostic laboratories. The technology of their application is described. The success of practical application of considered technology in the Federal system of external evaluation of quality is emphasized.
Integration of Diagnostic Microbiology in a Model of Total Laboratory Automation.
Da Rin, Giorgio; Zoppelletto, Maira; Lippi, Giuseppe
2016-02-01
Although automation has become widely utilized in certain areas of diagnostic testing, its adoption in diagnostic microbiology has proceeded much more slowly. To describe our real-world experience of integrating an automated instrument for diagnostic microbiology (Walk-Away Specimen Processor, WASPLab) within a model of total laboratory automation (TLA). The implementation process was divided into 2 phases. The former period, lasting approximately 6 weeks, entailed the installation of the WASPLab processor to operate as a stand-alone instrumentation, whereas the latter, lasting approximately 2 weeks, involved physical connection of the WASPLab with the automation. Using the WASPLab instrument in conjunction with the TLA model, we obtained a time savings equivalent to the work of 1.2 full-time laboratory technicians for diagnostic microbiology. The connection of WASPLab to TLA allowed its management by a generalist or clinical chemistry technician, with no need for microbiology skills on the part of either worker. Hence, diagnostic microbiology could be performed by the staff that is already using the TLA, extending their activities to include processing urgent clinical chemistry and hematology specimens. The time to result was also substantially improved. According to our experience, using the WASPLab instrument as part of a TLA in diagnostic microbiology holds great promise for optimizing laboratory workflow and improving the quality of testing. © American Society for Clinical Pathology, 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
78 FR 20112 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-03
...-related information. The respondents would be clinical laboratory supervisors, nurses, and other.../60 300 Supervisors. Influenza Diagnostic Test Practices in Clinical Laboratories. Nurses Survey of... this notice. Proposed Project Survey of Rapid Influenza Diagnostic Test (RIDT) Practices in Clinical...
Experimental evidence of multimaterial jet formation with lasers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nicolaie, Ph.; Stenz, C.; Tikhonchuk, V.
2010-11-15
Laser-produced multimaterial jets have been investigated at the Prague Asterix Laser System laser [K. Jungwirth et al., Phys. Plasmas 8, 2495 (2001)]. The method of jet production is based on the laser-plasma ablation process and proved to be easy to set up and robust. The possibility of multimaterial laboratory jet production is demonstrated and complex hydrodynamic flows in the jet body are obtained. Two complementary diagnostics in the optical ray and x-ray ranges provide detailed information about jet characteristics. The latter are in agreement with estimates and two-dimensional radiation hydrodynamic simulation results. The experiment provides a proof of principle thatmore » a velocity field could be produced and controlled in the jet body. It opens a possibility of astrophysical jet structure modeling in laboratory.« less
NASA Technical Reports Server (NTRS)
Horvitz, Eric; Ruokangas, Corinne; Srinivas, Sampath; Barry, Matthew
1993-01-01
We describe a collaborative research and development effort between the Palo Alto Laboratory of the Rockwell Science Center, Rockwell Space Operations Company, and the Propulsion Systems Section of NASA JSC to design computational tools that can manage the complexity of information displayed to human operators in high-stakes, time-critical decision contexts. We shall review an application from NASA Mission Control and describe how we integrated a probabilistic diagnostic model and a time-dependent utility model, with techniques for managing the complexity of computer displays. Then, we shall describe the behavior of VPROP, a system constructed to demonstrate promising display-management techniques. Finally, we shall describe our current research directions on the Vista 2 follow-on project.
Sá, Luísa; Costa-Santos, Cristina; Teixeira, Andreia; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto; Santos, Paulo; Martins, Carlos
2015-01-01
Background Physicians’ ability to make cost-effective decisions has been shown to be affected by their knowledge of health care costs. This study assessed whether Portuguese family physicians are aware of the costs of the most frequently prescribed diagnostic and laboratory tests. Methods A cross-sectional study was conducted in a representative sample of Portuguese family physicians, using computer-assisted telephone interviews for data collection. A Likert scale was used to assess physician’s level of agreement with four statements about health care costs. Family physicians were also asked to estimate the costs of diagnostic and laboratory tests. Each physician’s cost estimate was compared with the true cost and the absolute error was calculated. Results One-quarter (24%; 95% confidence interval: 23%–25%) of all cost estimates were accurate to within 25% of the true cost, with 55% (95% IC: 53–56) overestimating and 21% (95% IC: 20–22) underestimating the true actual cost. The majority (76%) of family physicians thought they did not have or were uncertain as to whether they had adequate knowledge of diagnostic and laboratory test costs, and only 7% reported receiving adequate education. The majority of the family physicians (82%) said that they had adequate access to information about the diagnostic and laboratory test costs. Thirty-three percent thought that costs did not influence their decision to order tests, while 27% were uncertain. Conclusions Portuguese family physicians have limited awareness of diagnostic and laboratory test costs, and our results demonstrate a need for improved education in this area. Further research should focus on identifying whether interventions in cost knowledge actually change ordering behavior, in identifying optimal methods to disseminate cost information, and on improving the cost-effectiveness of care. PMID:26356625
External Quality Assessment beyond the analytical phase: an Australian perspective.
Badrick, Tony; Gay, Stephanie; McCaughey, Euan J; Georgiou, Andrew
2017-02-15
External Quality Assessment (EQA) is the verification, on a recurring basis, that laboratory results conform to expectations for the quality required for patient care. It is now widely recognised that both the pre- and post-laboratory phase of testing, termed the diagnostic phases, are a significant source of laboratory errors. These errors have a direct impact on both the effectiveness of the laboratory and patient safety. Despite this, Australian laboratories tend to be focussed on very narrow concepts of EQA, primarily surrounding test accuracy, with little in the way of EQA programs for the diagnostic phases. There is a wide range of possibilities for the development of EQA for the diagnostic phases in Australia, such as the utilisation of scenarios and health informatics. Such programs can also be supported through advances in health information and communications technology, including electronic test ordering and clinical decision support systems. While the development of such programs will require consultation and support from the referring doctors, and their format will need careful construction to ensure that the data collected is de-identified and provides education as well as useful and informative data, we believe that there is high value in the development of such programs. Therefore, it is our opinion that all pathology laboratories should strive to be involved in an EQA program in the diagnostic phases to both monitor the diagnostic process and to identify, learn from and reduce errors and near misses in these phases in a timely fashion.
External Quality Assessment beyond the analytical phase: an Australian perspective
Gay, Stephanie; McCaughey, Euan J.; Georgiou, Andrew
2017-01-01
External Quality Assessment (EQA) is the verification, on a recurring basis, that laboratory results conform to expectations for the quality required for patient care. It is now widely recognised that both the pre- and post-laboratory phase of testing, termed the diagnostic phases, are a significant source of laboratory errors. These errors have a direct impact on both the effectiveness of the laboratory and patient safety. Despite this, Australian laboratories tend to be focussed on very narrow concepts of EQA, primarily surrounding test accuracy, with little in the way of EQA programs for the diagnostic phases. There is a wide range of possibilities for the development of EQA for the diagnostic phases in Australia, such as the utilisation of scenarios and health informatics. Such programs can also be supported through advances in health information and communications technology, including electronic test ordering and clinical decision support systems. While the development of such programs will require consultation and support from the referring doctors, and their format will need careful construction to ensure that the data collected is de-identified and provides education as well as useful and informative data, we believe that there is high value in the development of such programs. Therefore, it is our opinion that all pathology laboratories should strive to be involved in an EQA program in the diagnostic phases to both monitor the diagnostic process and to identify, learn from and reduce errors and near misses in these phases in a timely fashion. PMID:28392728
Beaver, Julia A.; Tzou, Abraham; Blumenthal, Gideon M.; McKee, Amy E.; Kim, Geoffrey; Pazdur, Richard; Philip, Reena
2016-01-01
As technologies evolve, and diagnostics move from detection of single biomarkers toward complex signatures, an increase in the clinical use and regulatory submission of complex signatures is anticipated. However, to date, no complex signatures have been approved as companion diagnostics. In this article, we will describe the potential benefit of complex signatures and their unique regulatory challenges including analytical performance validation, complex signature simulation, and clinical performance evaluation. We also will review the potential regulatory pathways for clearance, approval, or acceptance of complex signatures by the U.S. Food and Drug Administration (FDA). These regulatory pathways include regulations applicable to in vitro diagnostic devices, including companion diagnostic devices, the potential for labeling as a complementary diagnostic, and the biomarker qualification program. PMID:27993967
Assessment of biosafety precautions in Khartoum state diagnostic laboratories, Sudan
Elduma, Adel Hussein
2012-01-01
Background This study was conducted to evaluate the biosafety precautions that applied by diagnostic laboratories in Khartoum state, 2009. Methods A total number of 190 laboratories were surveyed about their compliance with standard biosafety precautions. These laboratories included 51 (27%) laboratories from government, 75 (39%) from private sectors and 64 (34%) laboratories belong to organization providing health care services. Results The study found that 32 (16.8%) of laboratories appointed biosafety officers. Only, ten (5.2%) participated in training about response to fire emergency, and 28 (14.7%) reported the laboratory accident occurred during work. 45 (23.7%) laboratories had a written standard operation procedures (SOPs), and 35 (18.4%) had written procedures for the lean-up of spills. Moreover, biosafety cabinet was found in 11 (5.8%) laboratories, autoclave in 28 (14.7%) and incinerator in only two (1.1%) laboratories. Sharp disposable containers were found in 84 (44.2%). Fire alarm system was found in 2 (1.1%) laboratories, fire extinguisher in 39 (20.5%) laboratories, and fire emergency exit found in 14 (7.4%) laboratories. Furthermore, 19 (10%) laboratories had a hepatitis B virus vaccination programme, 5 (6.2%) applied BCG vaccine, and 2 (1.1%0) vaccinated the staff against influenza. Conclusion The study concluded that the standards biosafety precautions adopted by the diagnostic laboratories in Khartoum state was very low. Further, the laboratory personnel awareness towards biosafety principles implementation was very low too. PMID:22514753
O'Daniel, Julianne M; McLaughlin, Heather M; Amendola, Laura M; Bale, Sherri J; Berg, Jonathan S; Bick, David; Bowling, Kevin M; Chao, Elizabeth C; Chung, Wendy K; Conlin, Laura K; Cooper, Gregory M; Das, Soma; Deignan, Joshua L; Dorschner, Michael O; Evans, James P; Ghazani, Arezou A; Goddard, Katrina A; Gornick, Michele; Farwell Hagman, Kelly D; Hambuch, Tina; Hegde, Madhuri; Hindorff, Lucia A; Holm, Ingrid A; Jarvik, Gail P; Knight Johnson, Amy; Mighion, Lindsey; Morra, Massimo; Plon, Sharon E; Punj, Sumit; Richards, C Sue; Santani, Avni; Shirts, Brian H; Spinner, Nancy B; Tang, Sha; Weck, Karen E; Wolf, Susan M; Yang, Yaping; Rehm, Heidi L
2017-05-01
While the diagnostic success of genomic sequencing expands, the complexity of this testing should not be overlooked. Numerous laboratory processes are required to support the identification, interpretation, and reporting of clinically significant variants. This study aimed to examine the workflow and reporting procedures among US laboratories to highlight shared practices and identify areas in need of standardization. Surveys and follow-up interviews were conducted with laboratories offering exome and/or genome sequencing to support a research program or for routine clinical services. The 73-item survey elicited multiple choice and free-text responses that were later clarified with phone interviews. Twenty-one laboratories participated. Practices highly concordant across all groups included consent documentation, multiperson case review, and enabling patient opt-out of incidental or secondary findings analysis. Noted divergence included use of phenotypic data to inform case analysis and interpretation and reporting of case-specific quality metrics and methods. Few laboratory policies detailed procedures for data reanalysis, data sharing, or patient access to data. This study provides an overview of practices and policies of experienced exome and genome sequencing laboratories. The results enable broader consideration of which practices are becoming standard approaches, where divergence remains, and areas of development in best practice guidelines that may be helpful.Genet Med advance online publication 03 Novemeber 2016.
Portable Diagnostics and Rapid Germination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dunn, Zachary Spencer
In the Bioenergy and Defense Department of Sandia National Laboratories, characterization of the BaDx (Bacillus anthracis diagnostic cartridge) was performed and rapid germination chemistry was investigated. BaDx was tested with complex sample matrixes inoculated with Bacillus anthracis, and the trials proved that BaDx will detect Bacillus anthracis in a variety of the medium, such as dirt, serum, blood, milk, and horse fluids. The dimensions of the device were altered to accommodate an E. coli or Listeria lateral flow immunoassay, and using a laser printer, BaDx devices were manufactured to identify E. coli and Listeria. Initial testing with E. coli versionsmore » of BaDx indicate that the device will be viable as a portable diagnostic cartridge. The device would be more effective with faster bacteria germination; hence studies were performed the use of rapid germination chemistry. Trials with calcium dipicolinic acid displayed increased cell germination, as shown by control studies using a microplate reader. Upon lyophilization the rapid germination chemistry failed to change growth patterns, indicating that the calcium dipicolinic acid was not solubilized under the conditions tested. Although incompatible with the portable diagnostic device, the experiments proved that the rapid germination chemistry was effective in increasing cell germination.« less
Diagnosis of inflammatory bowel disease: Potential role of molecular biometrics.
M'Koma, Amosy E
2014-11-27
Accurate diagnosis of predominantly colonic inflammatory bowel disease (IBD) is not possible in 30% of patients. For decades, scientists have worked to find a solution to improve diagnostic accuracy for IBD, encompassing Crohn's colitis and ulcerative colitis. Evaluating protein patterns in surgical pathology colectomy specimens of colonic mucosal and submucosal compartments, individually, has potential for diagnostic medicine by identifying integrally independent, phenotype-specific cellular and molecular characteristics. Mass spectrometry (MS) and imaging (I) MS are analytical technologies that directly measure molecular species in clinical specimens, contributing to the in-depth understanding of biological molecules. The biometric-system complexity and functional diversity is well suited to proteomic and diagnostic studies. The direct analysis of cells and tissues by Matrix-Assisted-Laser Desorption/Ionization (MALDI) MS/IMS has relevant medical diagnostic potential. MALDI-MS/IMS detection generates molecular signatures obtained from specific cell types within tissue sections. Herein discussed is a perspective on the use of MALDI-MS/IMS and bioinformatics technologies for detection of molecular-biometric patterns and identification of differentiating proteins. I also discuss a perspective on the global challenge of transferring technologies to clinical laboratories dealing with IBD issues. The significance of serologic-immunometric advances is also discussed.
Diagnosis of inflammatory bowel disease: Potential role of molecular biometrics
M’Koma, Amosy E
2014-01-01
Accurate diagnosis of predominantly colonic inflammatory bowel disease (IBD) is not possible in 30% of patients. For decades, scientists have worked to find a solution to improve diagnostic accuracy for IBD, encompassing Crohn’s colitis and ulcerative colitis. Evaluating protein patterns in surgical pathology colectomy specimens of colonic mucosal and submucosal compartments, individually, has potential for diagnostic medicine by identifying integrally independent, phenotype-specific cellular and molecular characteristics. Mass spectrometry (MS) and imaging (I) MS are analytical technologies that directly measure molecular species in clinical specimens, contributing to the in-depth understanding of biological molecules. The biometric-system complexity and functional diversity is well suited to proteomic and diagnostic studies. The direct analysis of cells and tissues by Matrix-Assisted-Laser Desorption/Ionization (MALDI) MS/IMS has relevant medical diagnostic potential. MALDI-MS/IMS detection generates molecular signatures obtained from specific cell types within tissue sections. Herein discussed is a perspective on the use of MALDI-MS/IMS and bioinformatics technologies for detection of molecular-biometric patterns and identification of differentiating proteins. I also discuss a perspective on the global challenge of transferring technologies to clinical laboratories dealing with IBD issues. The significance of serologic-immunometric advances is also discussed. PMID:25429322
Biljak, Vanja Radišić; Honović, Lorena; Matica, Jasminka; Krešić, Branka; Vojak, Sanela Šimić
2017-01-01
Chronic kidney disease (CKD) is a common clinical condition with significant adverse consequences for the patient and it is recognized as a significant public health problem. The role of laboratory medicine in diagnosis and management of CKD is of great importance: the diagnosis and staging are based on estimation of glomerular filtration rate (eGFR) and assessment of albuminuria (or proteinuria). Therefore, the joint working group of the Croatian society of medical biochemistry and laboratory medicine and Croatian chamber of medical biochemists for laboratory diagnostics in CKD issued this national recommendation regarding laboratory diagnostics of CKD. Key factors for laboratories implementing the national guidelines for the diagnosis and management of CKD are: 1. Ensure good communication between laboratory professionals and clinicians, such as nephrologists or specialists in general/family medicine, 2. Ensure all patients are provided with the same availability of laboratory diagnostics, 3. Ensure creatinine assays are traceable to isotope dilution mass spectrometry (IDMS) method and have minimal bias and acceptable imprecision, 4. Select the appropriate GFR estimating formula. Recommended equation is the 2009 Chronic Kidney Disease Epidemiology Collaboration (CKD – EPI) equation, 5. In reporting the key laboratory tests (creatinine, eGFR, urine albumin-to-creatinine ratio, urine protein-to-creatinine ratio) use the appropriate reporting units, 6. Provide adequate information on limitations of creatinine measurement. The manuscript has been organized to identify critical points in laboratory tests used in basic laboratory diagnostics of CKD and is based on the Kidney Disease: Improving Global Outcomes (KDIGO) 2012 Clinical Practice Guideline for the Evaluation and Management of Chronic Kidney Disease. PMID:28392738
Deans, Zandra C; Costa, Jose Luis; Cree, Ian; Dequeker, Els; Edsjö, Anders; Henderson, Shirley; Hummel, Michael; Ligtenberg, Marjolijn Jl; Loddo, Marco; Machado, Jose Carlos; Marchetti, Antonio; Marquis, Katherine; Mason, Joanne; Normanno, Nicola; Rouleau, Etienne; Schuuring, Ed; Snelson, Keeda-Marie; Thunnissen, Erik; Tops, Bastiaan; Williams, Gareth; van Krieken, Han; Hall, Jacqueline A
2017-01-01
The clinical demand for mutation detection within multiple genes from a single tumour sample requires molecular diagnostic laboratories to develop rapid, high-throughput, highly sensitive, accurate and parallel testing within tight budget constraints. To meet this demand, many laboratories employ next-generation sequencing (NGS) based on small amplicons. Building on existing publications and general guidance for the clinical use of NGS and learnings from germline testing, the following guidelines establish consensus standards for somatic diagnostic testing, specifically for identifying and reporting mutations in solid tumours. These guidelines cover the testing strategy, implementation of testing within clinical service, sample requirements, data analysis and reporting of results. In conjunction with appropriate staff training and international standards for laboratory testing, these consensus standards for the use of NGS in molecular pathology of solid tumours will assist laboratories in implementing NGS in clinical services.
Cheng, Chee Leong; Azhar, Rafay; Sng, Shi Hui Adeline; Chua, Yong Quan; Hwang, Jacqueline Siok Gek; Chin, Jennifer Poi Fun; Seah, Waih Khuen; Loke, Janel Chui Ling; Ang, Roy Hang Leng; Tan, Puay Hoon
2016-09-01
As digital pathology (DP) and whole slide imaging (WSI) technology advance and mature, there is an increasing drive to incorporate DP into the diagnostic environment. However, integration of DP into the diagnostic laboratory is a non-trivial task and filled with unexpected challenges unlike standalone implementations. We share our journey of implementing DP in the diagnostic laboratory setting, highlighting seven key guiding principles that drive the progression through implementation into deployment and beyond. The DP implementation with laboratory information system integration was completed in 8 months, including validation of the solution for diagnostic use in accordance with College of American Pathologists guidelines. We also conducted prospective validation via paired delivery of glass slides and WSI to our pathologists postdeployment. Common themes in our guiding principles included emphasis on workflow and being comprehensive in the approach, looking beyond pathologist user champions and expanding into an extended project team involving laboratory technicians, clerical/data room staff and archival staff. Concordance between glass slides and WSI ranged from 93% to 100% among various applications on validation. We also provided equal opportunities for every pathologist throughout the department to be competent and confident with DP through prospective validation, with overall concordance of 96% compared with glass slides, allowing appreciation of the advantages and limitations of WSI, hence enabling the use of DP as a useful diagnostic modality. Smooth integration of DP into the diagnostic laboratory is possible with careful planning, discipline and a systematic approach adhering to our guiding principles. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Molecular diagnostics for low resource settings
NASA Astrophysics Data System (ADS)
Weigl, Bernhard H.
2010-03-01
As traditional high quality diagnostic laboratories are not widely available or affordable in developing country health care settings, microfluidics-based point-of-care diagnostics may be able to address the need to perform complex assays in under-resourced areas. Many instrument-based as well as non-instrumented microfluidic prototype diagnostics are currently being developed. In addition to various engineering challenges, the greatest remaining issue is the search for truly low-cost disposable manufacturing methods. Diagnostics for global health, and specifically microfluidics and molecular-based low resource diagnostics, have become a very active research area over the last five years, thanks in part to new funding that became available from the Bill and Melinda Gates Foundation, the National Institutes of Health, and other sources. This has led to a number of interesting prototype devices that are now in advanced development or clinical validation. These devices include disposables and instruments that perform multiplexed PCR-based lab-on-a-chips for enteric, febrile, and vaginal diseases, as well as immunoassays for diseases such as malaria, HIV, and various sexually transmitted diseases. More recently, instrument-free diagnostic disposables based on isothermal nucleic acid amplification have been developed as well. Regardless of platform, however, the search for truly low-cost manufacturing methods that would result in cost of goods per disposable of around US1/unit at volume remains a big challenge. This talk will give an overview over existing platform development efforts as well as present some original research in this area at PATH.
Argonne Collaborative Center for Energy Storage Science (ACCESS)
Analysis and Diagnostics Laboratory (EADL) Post- Test Facility Access Proven Capabilities Argonne has Analysis, Modeling and Prototyping (CAMP) Electrochemical Analysis and Diagnostics Laboratory (EADL) Post -Test Facility Argonne User Facilities Industries Transportation Consumer Electronics Defense Electric
Mögling, Ramona; Zeller, Hervé; Revez, Joana; Koopmans, Marion; Reusken, Chantal
2017-01-01
With international travel, Zika virus (ZIKV) is introduced to Europe regularly. A country's ability to robustly detect ZIKV introduction and local transmission is important to minimise the risk for a ZIKV outbreak. Therefore, sufficient expertise and diagnostic capacity and capability are required in European laboratories. To assess the capacity, quality, operational specifics (guidelines and algorithms), technical and interpretation issues and other possible difficulties that were related to ZIKV diagnostics in European countries, a questionnaire was conducted among national reference laboratories in 30 countries in the European Union/European Economic Area (EU/EEA) in May 2016. While the coverage and capacity of ZIKV diagnostics in the EU/EEA national reference laboratories were found to be adequate, the assessment of the quality and needs indicated several crucial points of improvement that will need support at national and EU/EEA level to improve ZIKV preparedness, response and EU/EEA ZIKV surveillance activities. PMID:28920574
Laboratory development and testing of spacecraft diagnostics
NASA Astrophysics Data System (ADS)
Amatucci, William; Tejero, Erik; Blackwell, Dave; Walker, Dave; Gatling, George; Enloe, Lon; Gillman, Eric
2017-10-01
The Naval Research Laboratory's Space Chamber experiment is a large-scale laboratory device dedicated to the creation of large-volume plasmas with parameters scaled to realistic space plasmas. Such devices make valuable contributions to the investigation of space plasma phenomena under controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. However, in addition to investigations such as plasma wave and instability studies, such devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this talk, we will describe how the laboratory simulation of space plasmas made this development path possible. Work sponsored by the US Naval Research Laboratory Base Program.
Wildlife specimen collection, preservation, and shipment
White, C. LeAnn; Dusek, Robert J.; Franson, J. Christian; Friend, Milton; Gibbs, Samantha E.J.; Wild, Margaret A.
2015-01-01
Prior to collecting samples, it is important to determine the capabilities and submission criteria of the laboratory receiving the samples. Some laboratories may specialize in a limited number of tests, be equipped to accept only certain types of tissues (instead of entire carcasses), or specialize in particular species or group of animals (e.g., reptiles, birds, mammals). Diagnostic laboratories have specific requirements regarding preparation, labeling, and shipping of samples. Adherence to these requirements helps ensure the usefulness of any submitted specimens. Although laboratories may vary in the cost and turnaround times for diagnostic tests, some laboratories may be able to prioritize samples and accommodate accelerated time frames if communicated at the time of submission. Keeping a prepacked kit with basic carcass-collection supplies, including a paper copy of the specimen history form (available for download from the Web sites of most diagnostic laboratories), in the office or vehicle will decrease the chances of forgetting an essential item and decrease response time for arriving at an event.
Lumbreras-Lacarra, Blanca; Ramos-Rincón, José Manuel; Hernández-Aguado, Ildefonso
2004-03-01
The application of epidemiologic principles to clinical diagnosis has been less developed than in other clinical areas. Knowledge of the main flaws affecting diagnostic laboratory test research is the first step for improving its quality. We assessed the methodologic aspects of articles on laboratory tests. We included articles that estimated indexes of diagnostic accuracy (sensitivity and specificity) and were published in Clinical Chemistry or Clinical Chemistry and Laboratory Medicine in 1996, 2001, and 2002. Clinical Chemistry has paid special attention to this field of research since 1996 by publishing recommendations, checklists, and reviews. Articles were identified through electronic searches in Medline. The strategy combined the Mesh term "sensitivity and specificity" (exploded) with the text words "specificity", "false negative", and "accuracy". We examined adherence to seven methodologic criteria used in the study by Reid et al. (JAMA1995;274:645-51) of papers published in general medical journals. Three observers evaluated each article independently. Seventy-nine articles fulfilled the inclusion criteria. The percentage of studies that satisfied each criterion improved from 1996 to 2002. Substantial improvement was observed in reporting of the statistical uncertainty of indices of diagnostic accuracy, in criteria based on clinical information from the study population (spectrum composition), and in avoidance of workup bias. Analytical reproducibility was reported frequently (68%), whereas information about indeterminate results was rarely provided. The mean number of methodologic criteria satisfied showed a statistically significant increase over the 3 years in Clinical Chemistry but not in Clinical Chemistry and Laboratory Medicine. The methodologic quality of the articles on diagnostic test research published in Clinical Chemistry and Clinical Chemistry and Laboratory Medicine is comparable to the quality observed in the best general medical journals. The methodologic aspects that most need improvement are those linked to the clinical information of the populations studied. Editorial actions aimed to increase the quality of reporting of diagnostic studies could have a relevant positive effect, as shown by the improvement observed in Clinical Chemistry.
Magnusson, Bertil; Ossowicki, Haakan; Rienitz, Olaf; Theodorsson, Elvar
2012-05-01
Healthcare laboratories are increasingly joining into larger laboratory organizations encompassing several physical laboratories. This caters for important new opportunities for re-defining the concept of a 'laboratory' to encompass all laboratories and measurement methods measuring the same measurand for a population of patients. In order to make measurement results, comparable bias should be minimized or eliminated and measurement uncertainty properly evaluated for all methods used for a particular patient population. The measurement as well as diagnostic uncertainty can be evaluated from internal and external quality control results using GUM principles. In this paper the uncertainty evaluations are described in detail using only two main components, within-laboratory reproducibility and uncertainty of the bias component according to a Nordtest guideline. The evaluation is exemplified for the determination of creatinine in serum for a conglomerate of laboratories both expressed in absolute units (μmol/L) and relative (%). An expanded measurement uncertainty of 12 μmol/L associated with concentrations of creatinine below 120 μmol/L and of 10% associated with concentrations above 120 μmol/L was estimated. The diagnostic uncertainty encompasses both measurement uncertainty and biological variation, and can be estimated for a single value and for a difference. This diagnostic uncertainty for the difference for two samples from the same patient was determined to be 14 μmol/L associated with concentrations of creatinine below 100 μmol/L and 14 % associated with concentrations above 100 μmol/L.
Bartlett, John M S; Campbell, Fiona M; Ibrahim, Merdol; Thomas, Jeremy; Wencyk, Pete; Ellis, Ian; Kay, Elaine; Connolly, Yvonne; O'Grady, Anthony; Barnett, Sarah; Starczynski, Jane; Cunningham, Paul; Miller, Keith
2010-02-01
To assess a new HER2 fluorescence in situ hybridization (FISH) test and report on multicentre intrasite and intersite variation. HER2 results were scored from 45 breast cancers in eight laboratories using the Kreatech Poseidon HER2 FISH probe (Kreatech Diagnostics, Amsterdam, the Netherlands). Overall, 80.9% of cores were successfully analysed. Mean intrasite variation for HER2 ratio assessment was low (4.74%). Intersite variation in ratio was in line with previous reports (11.9+/-0.8%) for both reference and non-reference laboratories; only one laboratory displayed significantly higher intersite variation (P=0.009) than the remaining seven laboratories. The overall incidence of misclassification of cores was <1.3%, demonstrating an excellent level of concordance (>98.7%) across all eight laboratories, irrespective of whether they were 'reference' or 'routine diagnostic' laboratories. The Kreatech Poseidon HER2 FISH test is robust and reproducible. Highly quantitatively reproducible FISH results were obtained from eight 'diagnostic' and 'reference' laboratories; however, continued quality assessments are essential to good performance.
Code of Federal Regulations, 2014 CFR
2014-10-01
.... Nonphysician practitioners (that is, clinical nurse specialists, clinical psychologists, clinical social... that do not involve the use of contrast media; and (iii) Diagnostic mammograms if the approved portable...
Autoimmune diagnostics: the technology, the strategy and the clinical governance.
Bizzaro, Nicola; Tozzoli, Renato; Villalta, Danilo
2015-02-01
In recent years, there has been a profound change in autoimmune diagnostics. From long, tiring and inaccurate manual methods, the art of diagnostics has turned to modern, rapid and automated technology. New antibody tests have been developed, and almost all autoimmune diseases now have some specific diagnostic markers. The current need to make the most of available economic and human resources has led to the production of diagnostic algorithms and guidelines designated for optimal strategic use of the tests and to increase the diagnostic appropriateness. An important role in this scenario was assumed by the laboratory autoimmunologist, whose task is not only to govern the analytical phase, but also to help clinicians in correctly choosing the most suitable test for each clinical situation and provide consultancy support. In this review, we summarize recent advances in technology, describe the diagnostic strategies and highlight the current role of the laboratory autoimmunologist in the clinical governance of autoimmune diagnostics.
Implementation of HIV and Tuberculosis Diagnostics: The Importance of Context.
Dominique, Joyelle K; Ortiz-Osorno, Alberto A; Fitzgibbon, Joseph; Gnanashanmugam, Devasena; Gilpin, Christopher; Tucker, Timothy; Peel, Sheila; Peter, Trevor; Kim, Peter; Smith, Steven
2015-10-15
Novel diagnostics have been widely applied across human immunodeficiency virus (HIV) and tuberculosis prevention and treatment programs. To achieve the greatest impact, HIV and tuberculosis diagnostic programs must carefully plan and implement within the context of a specific healthcare system and the laboratory capacity. A workshop was convened in Cape Town in September 2014. Participants included experts from laboratory and clinical practices, officials from ministries of health, and representatives from industry. The article summarizes best practices, challenges, and lessons learned from implementation experiences across sub-Saharan Africa for (1) building laboratory programs within the context of a healthcare system; (2) utilizing experience of clinicians and healthcare partners in planning and implementing the right diagnostic; and (3) evaluating the effects of new diagnostics on the healthcare system and on patient health outcomes. The successful implementation of HIV and tuberculosis diagnostics in resource-limited settings relies on careful consideration of each specific context. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Evaluation of the Illumigene Malaria LAMP: A Robust Molecular Diagnostic Tool for Malaria Parasites
Lucchi, Naomi W.; Gaye, Marie; Diallo, Mammadou Alpha; Goldman, Ira F.; Ljolje, Dragan; Deme, Awa Bineta; Badiane, Aida; Ndiaye, Yaye Die; Barnwell, John W.; Udhayakumar, Venkatachalam; Ndiaye, Daouda
2016-01-01
Isothermal nucleic acid amplification assays such as the loop mediated isothermal amplification (LAMP), are well suited for field use as they do not require thermal cyclers to amplify the DNA. To further facilitate the use of LAMP assays in remote settings, simpler sample preparation methods and lyophilized reagents are required. The performance of a commercial malaria LAMP assay (Illumigene Malaria LAMP) was evaluated using two sample preparation workflows (simple filtration prep (SFP)) and gravity-driven filtration prep (GFP)) and pre-dispensed lyophilized reagents. Laboratory and clinical samples were tested in a field laboratory in Senegal and the results independently confirmed in a reference laboratory in the U.S.A. The Illumigene Malaria LAMP assay was easily implemented in the clinical laboratory and gave similar results to a real-time PCR reference test with limits of detection of ≤2.0 parasites/μl depending on the sample preparation method used. This assay reliably detected Plasmodium sp. parasites in a simple low-tech format, providing a much needed alternative to the more complex molecular tests for malaria diagnosis. PMID:27827432
The new medical-industrial complex.
Relman, A S
1980-10-23
The most important health-care development of the day is the recent, relatively unheralded rise of a huge new industry that supplies health-care services for profit. Proprietary hospitals and nursing homes, diagnostic laboratories, home-care and emergency-room services, hemodialysis, and a wide variety of other services produced a gross income to this industry last year of about $35 billion to +40 billion. This new "medical-industrial complex" may be more efficient than its nonprofit competition, but it creates the problems of overuse and fragmentation of services, overemphasis on technology, and "cream-skimming," and it may also exercise undue influence on national health policy. In this medical market, physicians must act as discerning purchasing agents for their patients and therefore should have no conflicting financial interests. Closer attention from the public and the profession, and careful study, are necessary to ensure that the "medical-industrial complex" puts the interest of the public before those of its stockholders.
Moro, Marilyn; Westover, M. Brandon; Kelly, Jessica; Bianchi, Matt T.
2016-01-01
Study Objectives: Obstructive sleep apnea (OSA) is associated with increased morbidity and mortality, and treatment with positive airway pressure (PAP) is cost-effective. However, the optimal diagnostic strategy remains a subject of debate. Prior modeling studies have not consistently supported the widely held assumption that home sleep testing (HST) is cost-effective. Methods: We modeled four strategies: (1) treat no one; (2) treat everyone empirically; (3) treat those testing positive during in-laboratory polysomnography (PSG) via in-laboratory titration; and (4) treat those testing positive during HST with auto-PAP. The population was assumed to lack independent reasons for in-laboratory PSG (such as insomnia, periodic limb movements in sleep, complex apnea). We considered the third-party payer perspective, via both standard (quality-adjusted) and pure cost methods. Results: The preferred strategy depended on three key factors: pretest probability of OSA, cost of untreated OSA, and time horizon. At low prevalence and low cost of untreated OSA, the treat no one strategy was favored, whereas empiric treatment was favored for high prevalence and high cost of untreated OSA. In-laboratory backup for failures in the at-home strategy increased the preference for the at-home strategy. Without laboratory backup in the at-home arm, the in-laboratory strategy was increasingly preferred at longer time horizons. Conclusion: Using a model framework that captures a broad range of clinical possibilities, the optimal diagnostic approach to uncomplicated OSA depends on pretest probability, cost of untreated OSA, and time horizon. Estimating each of these critical factors remains a challenge warranting further investigation. Citation: Moro M, Westover MB, Kelly J, Bianchi MT. Decision modeling in sleep apnea: the critical roles of pretest probability, cost of untreated obstructive sleep apnea, and time horizon. J Clin Sleep Med 2016;12(3):409–418. PMID:26518699
Lianidou, Evi; Ahmad-Nejad, Parviz; Ferreira-Gonzalez, Andrea; Izuhara, Kenji; Cremonesi, Laura; Schroeder, Maria-Eugenia; Richter, Karin; Ferrari, Maurizio; Neumaier, Michael
2014-09-25
Molecular techniques are becoming commonplace in the diagnostic laboratory. Their applications influence all major phases of laboratory medicine including predisposition/genetic risk, primary diagnosis, therapy stratification and prognosis. Readily available laboratory hardware and wetware (i.e. consumables and reagents) foster rapid dissemination to countries that are just establishing molecular testing programs. Appropriate skill levels extending beyond the technical procedure are required for analytical and diagnostic proficiency that is mandatory in molecular genetic testing. An international committee (C-CMBC) of the International Federation for Clinical Chemistry (IFCC) was established to disseminate skills in molecular genetic testing in member countries embarking on the respective techniques. We report the ten-year experience with different teaching and workshop formats for beginners in molecular diagnostics. Copyright © 2014 Elsevier B.V. All rights reserved.
How clinicians should use the diagnostic laboratory in a changing medical world.
Lundberg, G D
1999-02-01
In developed countries, clinicians are faced with a plethora of diagnostic tests to apply to patients to guide their clinical management. The quality, effectiveness, and efficiency of patient care should be foremost in the clinician's mind. Laboratory directors should make every effort to guide clinicians in appropriate laboratory test ordering, interpretation, and resulting actions. Medicine, being at its center a moral enterprise grounded in a covenant of trust, and laboratory medicine being a subset of medicine, must first care and advocate for the patient, and consider clinical outcomes as most important.
Roles of laboratories and laboratory systems in effective tuberculosis programmes.
Ridderhof, John C; van Deun, Armand; Kam, Kai Man; Narayanan, P R; Aziz, Mohamed Abdul
2007-05-01
Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB.
Laboratory Diagnosis of Echinococcus spp. in Human Patients and Infected Animals.
Siles-Lucas, M; Casulli, A; Conraths, F J; Müller, N
2017-01-01
Among the species composing the genus Echinococcus, four species are of human clinical interest. The most prevalent species are Echinococcus granulosus and Echinococcus multilocularis, followed by Echinococcus vogeli and Echinococcus oligarthrus. The first two species cause cystic echinococcosis (CE) and alveolar echinococcosis (AE) respectively. Both diseases have a complex clinical management, in which laboratory diagnosis could be an adjunctive to the imaging techniques. To date, several approaches have been described for the laboratory diagnosis and followup of CE and AE, including antibody, antigen and cytokine detection. All of these approaches are far from being optimal as adjunctive diagnosis particularly for CE, since they do not reach enough sensitivity and/or specificity. A combination of several methods (e.g., antibody and antigen detection) or of several (recombinant) antigens could improve the performance of the adjunctive laboratory methods, although the complexity of echinococcosis and heterogeneity of clinical cases make necessary a deep understanding of the host-parasite relationships and the parasite phenotype at different developmental stages to reach the best diagnostic tool and to make it accepted in clinical practice. Standardization approaches and a deep understanding of the performance of each of the available antigens in the diagnosis of echinococcosis for the different clinical pictures are also needed. The detection of the parasite in definitive hosts is also reviewed in this chapter. Finally, the different methods for the detection of parasite DNA in different analytes and matrices are also reviewed. Copyright © 2017 Elsevier Ltd. All rights reserved.
Tempestilli, Massimo; Pucci, Luigia; Notari, Stefania; Di Caro, Antonino; Castilletti, Concetta; Rivelli, Maria Rosaria; Agrati, Chiara; Pucillo, Leopoldo Paolo
2015-11-01
Ebola virus, an enveloped virus, is the cause of the largest and most complex Ebola virus disease (EVD) outbreak in West Africa. Blood or body fluids of an infected person may represent a biohazard to laboratory workers. Laboratory tests of virus containing specimens should be conducted in referral centres at biosafety level 4, but based on the severity of clinical symptoms, basic laboratories might be required to execute urgent tests for patients suspected of EVD. The aim of this work was to compare the analytical performances of laboratory tests when Triton X-100, a chemical agent able to inactivate other enveloped viruses, was added to specimens. Results of clinical chemistry, coagulation and haematology parameters on samples before and after the addition of 0.1% (final concentration) of Triton X-100 and 1 h of incubation at room temperature were compared. Overall, results showed very good agreement by all statistical analyses. Triton X-100 at 0.1% did not significantly affect the results for the majority of the analytes tested. Triton X-100 at 0.1% can be used to reduce the biohazard in performing laboratory tests on samples from patients with EVD without affecting clinical decisions.
Prucha, Miroslav; Bellingan, Geoff; Zazula, Roman
2015-02-02
Sepsis is the most frequent cause of death in non-coronary intensive care units (ICUs). In the past 10 years, progress has been made in the early identification of septic patients and in their treatment and these improvements in support and therapy mean that the mortality is gradually decreasing but it still remains unacceptably high. Leaving clinical diagnosis aside, the laboratory diagnostics represent a complex range of investigations that can place significant demands on the system given the speed of response required. There are hundreds of biomarkers which could be potentially used for diagnosis and prognosis in septic patients. The main attributes of successful markers would be high sensitivity, specificity, possibility of bed-side monitoring, and financial accessibility. Only a fraction is used in routine clinical practice because many lack sufficient sensitivity or specificity. The following review gives a short overview of the current epidemiology of sepsis, its pathogenesis and state-of-the-art knowledge on the use of specific biochemical, hematological and immunological parameters in its diagnostics. Prospective approaches towards discovery of new diagnostic biomarkers have been shortly mentioned. Copyright © 2014 Elsevier B.V. All rights reserved.
Schroeder, Lee F; Elbireer, Ali; Jackson, J Brooks; Amukele, Timothy K
2015-01-01
Diagnostic laboratory tests are routinely defined in terms of their sensitivity, specificity, and ease of use. But the actual clinical impact of a diagnostic test also depends on its availability and price. This is especially true in resource-limited settings such as sub-Saharan Africa. We present a first-of-its-kind report of diagnostic test types, availability, and prices in Kampala, Uganda. Test types (identity) and availability were based on menus and volumes obtained from clinical laboratories in late 2011 in Kampala using a standard questionnaire. As a measure of test availability, we used the Availability Index (AI). AI is the combined daily testing volumes of laboratories offering a given test, divided by the combined daily testing volumes of all laboratories in Kampala. Test prices were based on a sampling of prices collected in person and via telephone surveys in 2015. Test volumes and menus were obtained for 95% (907/954) of laboratories in Kampala city. These 907 laboratories offered 100 different test types. The ten most commonly offered tests in decreasing order were Malaria, HCG, HIV serology, Syphilis, Typhoid, Urinalysis, Brucellosis, Stool Analysis, Glucose, and ABO/Rh. In terms of AI, the 100 tests clustered into three groups: high (12 tests), moderate (33 tests), and minimal (55 tests) availability. 50% and 36% of overall availability was provided through private and public laboratories, respectively. Point-of-care laboratories contributed 35% to the AI of high availability tests, but only 6% to the AI of the other tests. The mean price of the most commonly offered test types was $2.62 (range $1.83-$3.46). One hundred different laboratory test types were in use in Kampala in late 2011. Both public and private laboratories were critical to test availability. The tests offered in point-of-care laboratories tended to be the most available tests. Prices of the most common tests ranged from $1.83-$3.46.
Sibley, Christopher D; Peirano, Gisele; Church, Deirdre L
2012-04-01
Clinical microbiology laboratories worldwide have historically relied on phenotypic methods (i.e., culture and biochemical tests) for detection, identification and characterization of virulence traits (e.g., antibiotic resistance genes, toxins) of human pathogens. However, limitations to implementation of molecular methods for human infectious diseases testing are being rapidly overcome allowing for the clinical evaluation and implementation of diverse technologies with expanding diagnostic capabilities. The advantages and limitation of molecular techniques including real-time polymerase chain reaction, partial or whole genome sequencing, molecular typing, microarrays, broad-range PCR and multiplexing will be discussed. Finally, terminal restriction fragment length polymorphism (T-RFLP) and deep sequencing are introduced as technologies at the clinical interface with the potential to dramatically enhance our ability to diagnose infectious diseases and better define the epidemiology and microbial ecology of a wide range of complex infections. Copyright © 2012 Elsevier B.V. All rights reserved.
Droplet-based Biosensing for Lab-on-a-Chip, Open Microfluidics Platforms
Dak, Piyush; Ebrahimi, Aida; Swaminathan, Vikhram; Duarte-Guevara, Carlos; Bashir, Rashid; Alam, Muhammad A.
2016-01-01
Low cost, portable sensors can transform health care by bringing easily available diagnostic devices to low and middle income population, particularly in developing countries. Sample preparation, analyte handling and labeling are primary cost concerns for traditional lab-based diagnostic systems. Lab-on-a-chip (LoC) platforms based on droplet-based microfluidics promise to integrate and automate these complex and expensive laboratory procedures onto a single chip; the cost will be further reduced if label-free biosensors could be integrated onto the LoC platforms. Here, we review some recent developments of label-free, droplet-based biosensors, compatible with “open” digital microfluidic systems. These low-cost droplet-based biosensors overcome some of the fundamental limitations of the classical sensors, enabling timely diagnosis. We identify the key challenges that must be addressed to make these sensors commercially viable and summarize a number of promising research directions. PMID:27089377
NASA Astrophysics Data System (ADS)
Yoo, Jongsoo; Jara-Almonte, J.; Majeski, S.; Frank, S.; Ji, H.; Yamada, M.
2016-10-01
FLARE (Facility for Laboratory Reconnection Experiments) will be operated as a flexible user facility, and so a complete set of research diagnostics is under development, including magnetic probe arrays, Langmuir probes, Mach probes, spectroscopic probes, and a laser interferometer. In order to accommodate the various requirements of users, large-scale (1 m), variable resolution (0.5-4 cm) magnetic probes have been designed, and are currently being prototyped. Moreover, a fully fiber-coupled laser interferometer has been designed to measure the line-integrated electron density. This fiber-coupled interferometer system will reduce the complexity of alignment processes and minimize maintenance of the system. Finally, improvements to the electrostatic probes and spectroscopic probes currently used in the Magnetic Reconnection Experiment (MRX) are discussed. The specifications of other subsystems, such as integrators and digitizers, are also presented. This work is supported by DoE Contract No. DE-AC0209CH11466.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tecza, J.
1998-06-01
'Safe and efficient clean up of hazardous and radioactive waste sites throughout the DOE complex will require extensive use of robots. This research effort focuses on developing Monitoring and Diagnostic (M and D) methods for robots that will provide early detection, isolation, and tracking of impending faults before they result in serious failure. The utility and effectiveness of applying M and D methods to hydraulic robots has never been proven. The present research program is utilizing seeded faults in a laboratory test rig that is representative of an existing hydraulically-powered remediation robot. This report summarizes activity conducted in the firstmore » 9 months of the project. The research team has analyzed the Rosie Mobile Worksystem as a representative hydraulic robot, developed a test rig for implanted fault testing, developed a test plan and agenda, and established methods for acquiring and analyzing the test data.'« less
Seely, John Curtis; Frazier, Kendall S
2015-06-01
Renal tubule lesions often prove troublesome for toxicologic pathologists because of the diverse nature and interrelated cell types within the kidney and the presence of spontaneous lesions with overlapping morphologies similar to those induced by renal toxicants. Although there are a number of guidance documents available citing straightforward diagnostic criteria of tubule lesions for the pathologist to refer to, most are presented without further advice on the when to or to the why and the why not of diagnosing one lesion over another. Documents presenting diagnostic perspectives and recommendations derived from an author's experience are limited since guidance documents are generally based on descriptive observations. In this Regulatory Forum opinion piece, the authors attempt to dispel confusing renal tubule lesion terminology in laboratory animal species by suggesting histological advice on the recognition and interpretation of these complex entities. © 2015 by The Author(s).
Droplet-based Biosensing for Lab-on-a-Chip, Open Microfluidics Platforms.
Dak, Piyush; Ebrahimi, Aida; Swaminathan, Vikhram; Duarte-Guevara, Carlos; Bashir, Rashid; Alam, Muhammad A
2016-04-14
Low cost, portable sensors can transform health care by bringing easily available diagnostic devices to low and middle income population, particularly in developing countries. Sample preparation, analyte handling and labeling are primary cost concerns for traditional lab-based diagnostic systems. Lab-on-a-chip (LoC) platforms based on droplet-based microfluidics promise to integrate and automate these complex and expensive laboratory procedures onto a single chip; the cost will be further reduced if label-free biosensors could be integrated onto the LoC platforms. Here, we review some recent developments of label-free, droplet-based biosensors, compatible with "open" digital microfluidic systems. These low-cost droplet-based biosensors overcome some of the fundamental limitations of the classical sensors, enabling timely diagnosis. We identify the key challenges that must be addressed to make these sensors commercially viable and summarize a number of promising research directions.
Brennan, Marie-Luise; Schrijver, Iris
2016-01-01
Cystic fibrosis (CF) is an autosomal recessive disease with significant associated morbidity and mortality. It is now appreciated that the broad phenotypic CF spectrum is not explained by obvious genotype-phenotype correlations, suggesting that CF transmembrane conductance regulator (CFTR)-related disease may occur because of multiple additive effects. These contributing effects include complex CFTR alleles, modifier genes, mutations in alternative genes that produce CF-like phenotypes, epigenetic factors, and environmental influences. Most patients in the United States are now diagnosed through newborn screening and use of molecular testing methods. We review the molecular testing approaches and laboratory guidelines for carrier screening, prenatal testing, newborn screening, and clinical diagnostic testing, as well as recent developments in CF treatment, and reasons for the lack of a molecular diagnosis in some patients. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Iredell, Jon; Thomas, Lee; Espedido, Björn
2006-12-01
The greatest impact of microbiology data on clinical care is in the critically ill. Unfortunately, this is also the area in which microbiology laboratories are most often non-contributive. Attempts to move to rapid, culture-independent diagnostics are driven by the need to expedite urgent results. This is difficult in Gram-negative infection because of the complexity of the antibiotic resistance phenotype. Here, we discuss resistance to modern beta-lactams as a case in point. Recent outbreaks of transmissible carbapenem resistance among Gram-negative enteric pathogens in Sydney and Melbourne serve to illustrate the pitfalls of traditional phenotypical approaches. A better understanding of the epidemiology and mosaic nature of antibiotic resistance elements in the microflora is needed for us to move forward.
Landi, Luca; Piccinelli, Stefano; Raia, Roberto; Marinotti, Fabio; Manicone, Paolo Francesco
2016-01-01
Treatment of complex perioprosthetic cases is one of the clinical challenges of everyday practice. Only a complete and thorough diagnostic setup may allow the clinician to formulate a realistic prognosis to select the abutments to support prosthetic rehabilitation. Clinical, radiographic, or laboratory parameters used separately are useless to correctly assign a reliable prognosis to single teeth except in the case of a clearly hopeless tooth. Therefore, it is crucial to gather the greatest quantity of data to determine the role that every single element can play in the prosthetic rehabilitation of the case. The following report deals with the management of a multidisciplinary periodontally compromised case in which a treatment strategy and chronology were designed to reach clinical predictability while reducing the duration of the therapy.
CLINICAL APPROACH TO THE DIAGNOSTIC EVALUATION OF HERDITARY AND ACQUIRED NEUROMUSCULAR DISEASES
McDonald, Craig M.
2012-01-01
SYNOPSIS In the context of a neuromuscular disease diagnostic evaluation, the clinician still must be able to obtain a relevant patient and family history and perform focused general, musculoskeletal, neurologic and functional physical examinations to direct further diagnostic evaluations. Laboratory studies for hereditary neuromuscular diseases include relevant molecular genetic studies. The EMG and nerve conduction studies remain an extension of the physical examination and help to guide further diagnostic studies such as molecular genetic studies, and muscle and nerve biopsies. All diagnostic information needs to be interpreted not in isolation, but within the context of relevant historical information, family history, physical examination findings, and laboratory data, electrophysiologic findings, pathologic findings, and molecular genetic findings if obtained. PMID:22938875
Effect of Accreditation on Accuracy of Diagnostic Tests in Medical Laboratories.
Jang, Mi Ae; Yoon, Young Ahn; Song, Junghan; Kim, Jeong Ho; Min, Won Ki; Lee, Ji Sung; Lee, Yong Wha; Lee, You Kyoung
2017-05-01
Medical laboratories play a central role in health care. Many laboratories are taking a more focused and stringent approach to quality system management. In Korea, laboratory standardization efforts undertaken by the Korean Laboratory Accreditation Program (KLAP) and the Korean External Quality Assessment Scheme (KEQAS) may have facilitated an improvement in laboratory performance, but there are no fundamental studies demonstrating that laboratory standardization is effective. We analyzed the results of the KEQAS to identify significant differences between laboratories with or without KLAP and to determine the impact of laboratory standardization on the accuracy of diagnostic tests. We analyzed KEQAS participant data on clinical chemistry tests such as albumin, ALT, AST, and glucose from 2010 to 2013. As a statistical parameter to assess performance bias between laboratories, we compared 4-yr variance index score (VIS) between the two groups with or without KLAP. Compared with the group without KLAP, the group with KLAP exhibited significantly lower geometric means of 4-yr VIS for all clinical chemistry tests (P<0.0001); this difference justified a high level of confidence in standardized services provided by accredited laboratories. Confidence intervals for the mean of each test in the two groups (accredited and non-accredited) did not overlap, suggesting that the means of the groups are significantly different. These results confirmed that practice standardization is strongly associated with the accuracy of test results. Our study emphasizes the necessity of establishing a system for standardization of diagnostic testing. © The Korean Society for Laboratory Medicine
LPA or GeneXpert in the diagnosis of multidrug-resistant tuberculosis.
Mindru, Roxana; Spinu, Victor; Popescu, Oana
2016-01-01
Facing a constant increase of multidrug-resistant tuberculosis (MDR-TB), there is large need for routine use of new diagnostic tests, based on molecular techniques that allow both a rapid diagnosis for TB complex and rapid identification of resistance mutations. The resistances are due to genetic factors: accumulation of changes within the genome structure, acquisition or loss of genes, spontaneous mutations in chromosomal genes, and changes that induce selection of resistant strains during a suboptimal treatment. The bacteriology laboratory plays a crucial role in the making of the diagnosis, monitoring and preventing TB transmission. World Health Organization offers consistent recommendations in favour of use of Xpert MTB/RIF, GeneXpert platform, as initial diagnostic test in adults and children suspected of TB, because it can simultaneously determine the presence of Mycobacterium tuberculosis and the Rifampicin resistance, which is a surrogate marker of MDR strains. The very high sensibility and specificity, also in the smear negative samples, as well as the short time needed for the results, make Xpert MTB/RIF a valuable tool in the fight against TB. Other recommended tests are: LPA, which identifies M. Tuberculosis complex, the Rifancim and Isoniazid resistance; MTBDR plus or, for second line anti-TB drugs, the MTBDRsl.
Lillis, Lorraine; Lehman, Dara A; Siverson, Joshua B; Weis, Julie; Cantera, Jason; Parker, Mathew; Piepenburg, Olaf; Overbaugh, Julie; Boyle, David S
2016-04-01
A low complexity diagnostic test that rapidly and reliably detects HIV infection in infants at the point of care could facilitate early treatment, improving outcomes. However, many infant HIV diagnostics can only be performed in laboratory settings. Recombinase polymerase amplification (RPA) is an isothermal amplification technology that can rapidly amplify proviral DNA from multiple subtypes of HIV-1 in under twenty minutes without complex equipment. In this study we added reverse transcription (RT) to RPA to allow detection of both HIV-1 RNA and DNA. We show that this RT-RPA HIV-1 assay has a limit of detection of 10-30 copies of an exact sequence matched DNA or RNA, respectively. In addition, at 100 copies of RNA or DNA, the assay detected 171 of 175 (97.7%) sequence variants that represent all the major subtypes and recombinant forms of HIV-1 Groups M and O. This data suggests that the application of RT-RPA for the combined detection of HIV-1 viral RNA and proviral DNA may prove a highly sensitive tool for rapid and accurate diagnosis of infant HIV. Copyright © 2016 Elsevier B.V. All rights reserved.
De Clercq, K; Goris, N; Barnett, P V; MacKay, D K
2008-01-01
The last decade international trade in animals and animal products was liberated and confidence in this global trade can increase only if appropriate control measures are applied. As foot-and-mouth disease (FMD) diagnostics will play an essential role in this respect, the Food and Agriculture Organization European Commission for the Control of Foot-and-Mouth Disease (EUFMD) co-ordinates, in collaboration with the European Commission, several programmes to increase the quality of FMD diagnostics. A quality assurance (QA) system is deemed essential for laboratories involved in certifying absence of FMDV or antibodies against the virus. Therefore, laboratories are encouraged to validate their diagnostic tests fully and to install a continuous quality control (QC) monitoring system. Knowledge of performance characteristics of diagnostics is essential to interpret results correctly and to calculate sample rates in regional surveillance campaigns. Different aspects of QA/QC of classical and new FMD virological and serological diagnostics are discussed in respect to the EU FMD directive (2003/85/EC). We recommended accepting trade certificates only from laboratories participating in international proficiency testing on a regular basis.
[TRAUMATIC INTRAORGANIC HEPATIC AND SPLENIC HEMATOMAS].
Timerbulatov, V M; Khalikov, A A; Timerbulatov, Sh V; Verzakova, I V; Amirova, A M; Smyr, R A
2015-01-01
An analysis of application results of complex research methods of diagnostics of intraorganic hepatic and splenic hematomas was made. At the same time, options of these methods were used for determination of prescription of injury. The ultrasound, CT, MR-imaging, videolaparoscopy, angiography, Doppler ultrasonics, impedometry, biochemical, laboratory and cytological study of punctate sample from hematomas were applied for this purpose in 33 patients. According to authors, an evolution of hematomas happened in 3 stages, each of this stage was characterized by specified data associated with investigation results. The staging procedure of hematomas or their evolution allowed setting the prescription of injury.
Evaluation of the enterovirus laboratory surveillance system in Denmark, 2010 to 2013.
Condell, Orla; Midgley, Sofie; Christiansen, Claus Bohn; Chen, Ming; Chen Nielsen, Xiaohui; Ellermann-Eriksen, Svend; Mølvadgaard, Mette; Schønning, Kristian; Vermedal Hoegh, Silje; Andersen, Peter Henrik; Voldstedlund, Marianne; Fischer, Thea Kølsen
2016-05-05
The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus-transmission in a timely manner. We evaluate the national EV laboratory surveillance, to generate recommendations for system strengthening. The system was analysed for completeness of viral typing analysis and clinical information and timeliness of specimen collection, laboratory results and reporting of clinical information. Of 23,720 specimens screened, 2,202 (9.3%) were EV-positive. Submission of cerebrospinal fluid and faecal specimens from primary diagnostic laboratories was 79.5% complete (845/1,063), and varied by laboratory and patient age. EV genotypes were determined in 68.5% (979/1,430) of laboratory-confirmed cases, clinical information was available for 63.1% (903/1,430). Primary diagnostic results were available after a median of 1.4 days, typing results after 17 days, detailed clinical information after 33 days. The large number of samples typed demonstrated continued monitoring of EV-circulation in Denmark. The system could be strengthened by increasing the collection of supplementary faecal specimens, improving communication with primary diagnostic laboratories, adapting the laboratory typing methodology and collecting clinical information with electronic forms.
Naicker, Serisha D; Govender, Nevashan; Patel, Jaymati; Zietsman, Inge L; Wadula, Jeannette; Coovadia, Yacoob; Kularatne, Ranmini; Seetharam, Sharona; Govender, Nelesh P
2016-11-01
From February 2009 through August 2010, we compared species-level identification of bloodstream Candida isolates and susceptibility to fluconazole, voriconazole, and caspofungin between diagnostic and reference South African laboratories during national surveillance for candidemia. Diagnostic laboratories identified isolates to genus/species level and performed antifungal susceptibility testing, as indicated. At a reference laboratory, viable Candida isolates were identified to species-level using automated systems, biochemical tests, or DNA sequencing; broth dilution susceptibility testing was performed. Categorical agreement (CA) was calculated for susceptibility results of isolates with concordant species identification. Overall, 2172 incident cases were detected, 773 (36%) by surveillance audit. The Vitek 2 YST system (bioMérieux Inc, Marcy l'Etoile, France) was used for identification (360/863, 42%) and susceptibility testing (198/473, 42%) of a large proportion of isolates. For the five most common species (n = 1181), species-level identification was identical in the majority of cases (Candida albicans: 98% (507/517); Candida parapsilosis: 92% (450/488); Candida glabrata: 89% (89/100); Candida tropicalis: 91% (49/54), and Candida krusei: 86% (19/22)). However, diagnostic laboratories were significantly less likely to correctly identify Candida species other than C. albicans versus C. albicans (607/664, 91% vs. 507/517, 98%; P < .001). Susceptibility data were compared for isolates belonging to the five most common species and fluconazole, voriconazole, and caspofungin in 860, 580, and 99 cases, respectively. Diagnostic laboratories significantly under-reported fluconazole resistance in C. parapsilosis (225/393, 57% vs. 239/393, 61%; P < .001) but over-reported fluconazole non-susceptibility in C. albicans (36/362, 10% vs. 3/362, 0.8%; P < .001). Diagnostic laboratories were less likely to correctly identify Candida species other than C. albicans, under-reported fluconazole resistance for C. parapsilosis and over-reported fluconazole resistance for C. albicans. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
[Evaluation of quality of HIV diagnostic procedures in Poland].
Parczewski, Miłosz; Madaliński, Kazimierz; Leszczyszyn-Pynka, Magdalena; Boroń-Kaczmarska, Anna
2010-01-01
The aim of this work was quality assessment of HIV diagnostic procedures in Poland, including human and technical resources as well as laboratory practice. Sixty questionnaires were distributed among diagnostic centers to obtain qualitative data. Basing on the survey data serological control using coded panels of HIV-1/2 samples was performed. Thirty-one filled questionnaires were received (50.8%). Surveyed laboratories perform from 350 to 5500 serological screening tests per year. In most of laboratories fourth generation assays are available, while Blood Donation Centers screen the blood both with serological assays and by HIV-RNA detection. Sanitary and Epidemiological Stations and academic laboratories hold the ISO/IEC 17025 or IS0 9001:2001 accreditation, five of the surveyed centers participate in Labquality assurance and two in Quality Control in Molecular Diagnostics programs. Data of control serological testing were received from 21 centers. In the quality control assessment 194 analyses were performed with 91 true negative, 2 false negative, 96 true positive and 5 false positive results. False negative rate of % and false positive rate of 5.2% was noted for this study. Currently, virtually no guidelines related to the HIV-diagnostics quality assurance and control in Poland are in delineated. Development of the national unified quality control system, basing on the central institution is highly desirable. National certification within the frames of the quality control and assurance program should be mandatory for all the diagnostic labs, and aim at improvement of reliability of the result distributed among clinicians and patients.
DRG Watchdog highlights new financial dimensions of laboratory diagnostics.
2003-01-01
As nebulous as the details of the German diagnosis-oriented case reimbursement rate (G-DRGs) might be, one thing is obvious: rapid and accurate diagnostics will be vital in future to the reimbursement of standard cases that reflect the actual outlay. The laboratory that up to now has always been categorized as a potential for savings, now becomes a source of revenue for hospitals. A study initiated by the VDGH provides evidence for this (Clinical Laboratory 2002, 48, 327).
Effect of Accreditation on Accuracy of Diagnostic Tests in Medical Laboratories
Jang, Mi-Ae; Yoon, Young Ahn; Song, Junghan; Kim, Jeong-Ho; Min, Won-Ki; Lee, Ji Sung
2017-01-01
Background Medical laboratories play a central role in health care. Many laboratories are taking a more focused and stringent approach to quality system management. In Korea, laboratory standardization efforts undertaken by the Korean Laboratory Accreditation Program (KLAP) and the Korean External Quality Assessment Scheme (KEQAS) may have facilitated an improvement in laboratory performance, but there are no fundamental studies demonstrating that laboratory standardization is effective. We analyzed the results of the KEQAS to identify significant differences between laboratories with or without KLAP and to determine the impact of laboratory standardization on the accuracy of diagnostic tests. Methods We analyzed KEQAS participant data on clinical chemistry tests such as albumin, ALT, AST, and glucose from 2010 to 2013. As a statistical parameter to assess performance bias between laboratories, we compared 4-yr variance index score (VIS) between the two groups with or without KLAP. Results Compared with the group without KLAP, the group with KLAP exhibited significantly lower geometric means of 4-yr VIS for all clinical chemistry tests (P<0.0001); this difference justified a high level of confidence in standardized services provided by accredited laboratories. Confidence intervals for the mean of each test in the two groups (accredited and non-accredited) did not overlap, suggesting that the means of the groups are significantly different. Conclusions These results confirmed that practice standardization is strongly associated with the accuracy of test results. Our study emphasizes the necessity of establishing a system for standardization of diagnostic testing. PMID:28224767
Friedman, B A
2001-08-01
Major forces are now reshaping all businesses on a global basis, including the healthcare and clinical laboratory industries. One of the major forces at work is information technology (IT), which now provides the opportunity to create a new economic and business model for the clinical laboratory industry based on the creation of an integrated vertical meta-network, referred to here as the "total laboratory solution" (TLS). Participants at the most basic level of such a network would include a hospital-based laboratory, a reference laboratory, a laboratory information system/application service provider/laboratory portal vendor, an in vitro diagnostic manufacturer, and a pharmaceutical/biotechnology manufacturer. It is suggested that each of these participants would add value to the network primarily in its area of core competency. Subvariants of such a network have evolved over recent years, but a TLS comprising all or most of these participants does not exist at this time. Although the TLS, enabled by IT and closely akin to the various e-businesses that are now taking shape, offers many advantages from a theoretical perspective over the current laboratory business model, its success will depend largely on (a) market forces, (b) how the collaborative networks are organized and managed, and (c) whether the network can offer healthcare organizations higher quality testing services at lower cost. If the concept is successful, new demands will be placed on hospital-based laboratory professionals to shift the range of professional services that they offer toward clinical consulting, integration of laboratory information from multiple sources, and laboratory information management. These information management and integration tasks can only increase in complexity in the future as new genomic and proteomics testing modalities are developed and come on-line in clinical laboratories.
Medical microbiology: laboratory diagnosis of invasive pneumococcal disease.
Werno, Anja M; Murdoch, David R
2008-03-15
The laboratory diagnosis of invasive pneumococcal disease (IPD) continues to rely on culture-based methods that have been used for many decades. The most significant recent developments have occurred with antigen detection assays, whereas the role of nucleic acid amplification tests has yet to be fully clarified. Despite developments in laboratory diagnostics, a microbiological diagnosis is still not made in most cases of IPD, particularly for pneumococcal pneumonia. The limitations of existing diagnostic tests impact the ability to obtain accurate IPD burden data and to assess the effectiveness of control measures, such as vaccination, in addition to the ability to diagnose IPD in individual patients. There is an urgent need for improved diagnostic tests for pneumococcal disease--especially tests that are suitable for use in underresourced countries.
Liang, Xiao; Chigerwe, Munashe; Hietala, Sharon K; Crossley, Beate M
2014-06-01
In order to improve the analytic quality of respiratory specimens collected from cattle for nucleic acid-based diagnosis, a study was undertaken to verify realtime PCR efficiency of specimens collected and stabilized on FTA Cards™, filter paper which is treated chemically. Nucleic acids collected using FTA Cards without the need for a cold-chain or special liquid media handling provided realtime PCR results consistent (96.8% agreement, kappa 0.923 [95% CI=0.89-0.96]) with the same specimens collected using traditional viral transport media and shipped on ice using the U.S. Department of Transportation mandated liquid handling requirements. Nucleic acid stabilization on FTA Cards was evaluated over a temperature range (-27 °C to +46 °C) for up to 14 days to mimic environmental conditions for diagnostic sample handling between collection and processing in a routine veterinary laboratory. No significant difference (P≥0.05) was observed in realtime PCR cycle threshold values over the temperature range and time storage conditions for Bovine Viral Diarrhea virus, Bovine Respiratory Syncytial virus, Bovine Coronavirus, and Bovine Herpesvirus I. The four viruses evaluated in the study are associated with Bovine Respiratory Disease Complex where improvements in ease and reliability of specimen collection and shipping would enhance the diagnostic quality of specimens collected in the field, and ultimately improve diagnostic efficiency. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Rigamonti, D.; Giacomelli, L.; Gorini, G.; Nocente, M.; Rebai, M.; Tardocchi, M.; Angelone, M.; Batistoni, P.; Cufar, A.; Ghani, Z.; Jednorog, S.; Klix, A.; Laszynska, E.; Loreti, S.; Pillon, M.; Popovichev, S.; Roberts, N.; Thomas, D.; Contributors, JET
2018-04-01
An accurate calibration of the JET neutron diagnostics with a 14 MeV neutron generator was performed in the first half of 2017 in order to provide a reliable measurement of the fusion power during the next JET deuterium-tritium (DT) campaign. In order to meet the target accuracy, the chosen neutron generator has been fully characterized at the Neutron Metrology Laboratory of the National Physical Laboratory (NPL), Teddington, United Kingdom. The present paper describes the measurements of the neutron energy spectra obtained using a high-resolution single-crystal diamond detector (SCD). The measurements, together with a new neutron source routine ‘ad hoc’ developed for the MCNP code, allowed the complex features of the neutron energy spectra resulting from the mixed D/T beam ions interacting with the T/D target nuclei to be resolved for the first time. From the spectral analysis a quantitative estimation of the beam ion composition has been made. The unprecedented intrinsic energy resolution (<1% full width at half maximum (FWHM) at 14 MeV) of diamond detectors opens up new prospects for diagnosing DT plasmas, such as, for instance, the possibility to study non-classical slowing down of the beam ions by neutron spectroscopy on ITER.
Clinical application of high throughput molecular screening techniques for pharmacogenomics
Wiita, Arun P; Schrijver, Iris
2011-01-01
Genetic analysis is one of the fastest-growing areas of clinical diagnostics. Fortunately, as our knowledge of clinically relevant genetic variants rapidly expands, so does our ability to detect these variants in patient samples. Increasing demand for genetic information may necessitate the use of high throughput diagnostic methods as part of clinically validated testing. Here we provide a general overview of our current and near-future abilities to perform large-scale genetic testing in the clinical laboratory. First we review in detail molecular methods used for high throughput mutation detection, including techniques able to monitor thousands of genetic variants for a single patient or to genotype a single genetic variant for thousands of patients simultaneously. These methods are analyzed in the context of pharmacogenomic testing in the clinical laboratories, with a focus on tests that are currently validated as well as those that hold strong promise for widespread clinical application in the near future. We further discuss the unique economic and clinical challenges posed by pharmacogenomic markers. Our ability to detect genetic variants frequently outstrips our ability to accurately interpret them in a clinical context, carrying implications both for test development and introduction into patient management algorithms. These complexities must be taken into account prior to the introduction of any pharmacogenomic biomarker into routine clinical testing. PMID:23226057
Ishengoma, D R S; Rwegoshora, R T; Mdira, K Y; Kamugisha, M L; Anga, E O; Bygbjerg, I C; Rønn, A M; Magesa, S M
2009-07-01
Although critical for good case management and the monitoring of health interventions, the health-laboratory services in sub-Saharan Africa are grossly compromised by poor infrastructures and a lack of trained personnel, essential reagents and other supplies. The availability and quality of diagnostic services in 37 health laboratories in three districts of the Tanga region of Tanzania have recently been assessed. The results of the survey, which involved interviews with health workers, observations and a documentary review, revealed that malaria accounted for >50% of admissions and out-patient visits. Most (92%) of the laboratories were carrying out malaria diagnosis and 89% were measuring haemoglobin concentrations but only one (3%) was conducting culture and sensitivity tests, and those only on urine and pus samples. Only 14 (17%) of the 84 people found working in the visited laboratories were laboratory technologists with a diploma certificate or higher qualification. Sixteen (43%) of the study laboratories each had five or fewer types of equipment and only seven (19%) had more than 11 types each. Although 11 (30%) of the laboratories reported that they conducted internal quality control, none had standard operating procedures (SOP) on display or evidence of such quality assurance. Although malaria was the main health problem, diagnostic services for malaria and other diseases were inadequate and of poor quality because of the limited human resources, poor equipment and shortage of supplies. If the health services in Tanga are not to be overwhelmed by the progressively increasing burden of HIV/AIDS, malaria, tuberculosis and other emerging and re-emerging diseases, more funding and appropriate policies to improve the availability and quality of the area's diagnostic services will clearly be required.
Ishengoma, Deus S; Kamugisha, Mathias L; Rutta, Acleus S M; Kagaruki, Gibson B; Kilale, Andrew M; Kahwa, Amos; Kamugisha, Erasmus; Baraka, Vito; Mandara, Celine I; Materu, Godlisten S; Massaga, Julius J; Magesa, Stephen M; Lemnge, Martha M; Mboera, Leonard E G
2017-01-23
Roll-out and implementation of antiretroviral therapy (ART) necessitated many countries in Sub-Saharan Africa to strengthen their national health laboratory systems (NHLSs) to provide high quality HIV diagnostic and supportive services. This study was conducted to assess the performance of health laboratories in provision of HIV diagnostic and supportive services in eight districts (from four regions of Iringa, Mtwara, Tabora and Tanga), after nine years of implementation of HIV/AIDS care and treatment plan in Tanzania. In this cross-sectional study, checklists and observations were utilized to collect information from health facilities (HFs) with care and treatment centres (CTCs) for HIV/AIDS patients; on availability of laboratories, CTCs, laboratory personnel, equipment and reagents. A checklist was also used to collect information on implementation of quality assurance (QA) systems at all levels of the NHLS in the study areas. The four regions had 354 HFs (13 hospitals, 41 Health Centres (HCs) and 300 dispensaries); whereby all hospitals had laboratories and 11 had CTCs while 97.5 and 61.0% of HCs had both laboratories and CTCs, respectively. Of the dispensaries, 36.0 and 15.0% had laboratories and CTCs (mainly in urban areas). Thirty nine HFs (12 hospitals, 21 HCs and six dispensaries) were assessed and 56.4% were located in urban areas. The assessed HFs had 199 laboratory staff of different cadres (laboratory assistants = 35.7%; technicians =32.7%; attendants = 22.6%; and others = 9.1%); with >61% of the staff and 72.3% of the technicians working in urban areas. All laboratories were using rapid diagnostic tests for HIV testing. Over 74% of the laboratories were performing internal quality control and 51.4% were participating in external QA programmes. Regional and district laboratories had all key equipment and harmonization was maintained for Fluorescence-Activated Cell Sorting (FACS) machines. Most of the biochemical (58.0%) and haematological analysers (74.1%) were available in urban areas. Although >81% of the equipment were functional with no mechanical faulty, 62.6% had not been serviced in the past three years. Diagnostic and supportive services for HIV were available in most of the HCs and hospitals while few dispensaries were providing the services. Due to limitations such as shortage of staff, serving of equipment and participation in QA programmes, the NHLS should be strengthened to ensure adequate human resource, implementation of QA and sustainable preventive maintenance services of equipment.
Smith, Michael T.; Wickwire, Emerson M.; Grace, Edward G.; Edwards, Robert R.; Buenaver, Luis F.; Peterson, Stephen; Klick, Brendan; Haythornthwaite, Jennifer A.
2009-01-01
Study Objectives: We characterized sleep disorder rates in temporomandibular joint disorder (TMD) and evaluated possible associations between sleep disorders and laboratory measures of pain sensitivity. Design: Research diagnostic examinations were conducted, followed by two consecutive overnight polysomnographic studies with morning and evening assessments of pain threshold. Setting: Orofacial pain clinic and inpatient sleep research facility Participants: Fifty-three patients meeting research diagnostic criteria for myofascial TMD. Interventions: N/A Measurements and Results: We determined sleep disorder diagnostic rates and conducted algometric measures of pressure pain threshold on the masseter and forearm. Heat pain threshold was measured on the forearm; 75% met self-report criteria for sleep bruxism, but only 17% met PSG criteria for active sleep bruxism. Two or more sleep disorders were diagnosed in 43% of patients. Insomnia disorder (36%) and sleep apnea (28.4%) demonstrated the highest frequencies. Primary insomnia (PI) (26%) comprised the largest subcategory of insomnia. Even after controlling for multiple potential confounds, PI was associated with reduced mechanical and thermal pain thresholds at all sites (P < 0.05). Conversely, the respiratory disturbance index was associated with increased mechanical pain thresholds on the forearm (P < 0.05). Conclusions: High rates of PI and sleep apnea highlight the need to refer TMD patients complaining of sleep disturbance for polysomnographic evaluation. The association of PI and hyperalgesia at a non-orofacial site suggests that PI may be linked with central sensitivity and could play an etiologic role in idiopathic pain disorders. The association between sleep disordered breathing and hypoalgesia requires further study and may provide novel insight into the complex interactions between sleep and pain-regulatory processes. Citation: Smith MT; Wickwire EM; Grace EG; Edwards RR; Buenaver LF; Peterson S; Klick B; Haythornthwaite JA. Sleep disorders and their association with laboratory pain sensitivity in temporomandibular joint disorder. SLEEP 2009;32(6):779–790. PMID:19544755
42 CFR 414.510 - Laboratory date of service for clinical laboratory and pathology specimens.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 3 2010-10-01 2010-10-01 false Laboratory date of service for clinical laboratory... AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.510 Laboratory date of service for clinical laboratory and pathology specimens. The date of service for either a...
Barreto, Leonardo Bruno Paz Ferreira; Lourenço, Maria Cristina da Silva; Rolla, Valéria Cavalcanti; Veloso, Valdiléia Gonçalves; Huf, Gisele
2014-01-01
To compare the accuracy of the amplified Mycobacterium tuberculosis direct (AMTD) test with reference methods for the laboratory diagnosis of tuberculosis in HIV-infected patients. This was a study of diagnostic accuracy comparing AMTD test results with those obtained by culture on Löwenstein-Jensen (LJ) medium and by the BACTEC Mycobacteria Growth Indicator Tube 960 (BACTEC MGIT 960) system in respiratory samples analyzed at the Bioassay and Bacteriology Laboratory of the Oswaldo Cruz Foundation Evandro Chagas Clinical Research Institute in the city of Rio de Janeiro, Brazil. We analyzed respiratory samples collected from 118 patients, of whom 88 (74.4%) were male. The mean age was 36.6 ± 10.6 years. Using the AMTD test, the BACTEC MGIT 960 system, and LJ culture, we identified M. tuberculosis complex in 31.0%, 29.7%, and 27.1% of the samples, respectively. In comparison with LJ culture, the AMTD test had a sensitivity, specificity, positive predictive value, and negative predictive value of 87.5%, 89.4%, 75.7%, and 95.0%, respectively, for LJ culture, whereas, in comparison with the BACTEC MGIT 960 system, it showed values of 88.6%, 92.4%, 83.8%, and 94.8%, respectively. The AMTD test showed good sensitivity and specificity in the population studied, enabling the laboratory detection of M. tuberculosis complex in paucibacillary respiratory specimens.
Maroney, Justin; Khan, Saba; Powell, Wayne; Klein, Lloyd W
2013-01-01
We seek to assess the per-operator volume of diagnostic catheterizations and percutaneous coronary interventions (PCI) among US cardiologists, and its implication for future manpower needs in the catheterization laboratory. The number of annual Medicare PCIs peaked in 2004 and has trended downward since, however the total number of catheterization laboratories nationwide has increased. It is unknown whether these trends have resulted in a dilution of per-operator volumes, and whether the current supply of interventional cardiologists is appropriate to meet future needs. We analyzed the Centers for Medicare and Medicaid Services 2008 Medicare 5% sample file, and extracted the total number of Medicare fee-for-service (Medicare FFS) diagnostic catheterizations and PCIs performed in 2008. We then determined per-physician procedure volumes using National Provider Identifier numbers. There were 1,198,610 Medicare FFS diagnostic catheterizations performed by 11,029 diagnostic cardiologists, and there were 378,372 Medicare FFS PCIs performed by 6,443 interventional cardiologists in 2008. The data reveal a marked difference in the 2008 distribution of diagnostic catheterizations and PCIs among operators. Just over 10% of diagnostic catheterizations were performed by operators performing 40 or fewer Medicare FFS diagnostic catheterizations, contrasted with almost 30% of PCIs performed by operators with 40 of fewer Medicare FFS PCIs. A significant majority of interventional cardiologists (61%) performed 40 or fewer Medicare FFS PCIs in 2008. There is a high percentage of low-volume operators performing PCI, raising questions regarding annual volume recommendations for procedural skill maintenance, and the future manpower requirements in the catheterization laboratory. Copyright © 2012 Wiley Periodicals, Inc.
Point-of-Care Diagnostics for Niche Applications
Cummins, Brian M.; Ligler, Frances S.; Walker, Glenn M.
2016-01-01
Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. PMID:26837054
Roles of laboratories and laboratory systems in effective tuberculosis programmes
van Deun, Armand; Kam, Kai Man; Narayanan, PR; Aziz, Mohamed Abdul
2007-01-01
Abstract Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories’ functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB. PMID:17639219
Plasmakristall-4: A microgravity complex plasma facility on the way to launch
NASA Astrophysics Data System (ADS)
Pustylnik, Mikhail; Thomas, Hubertus; Fortov, Vladimir; Thoma, Markus; Lipaev, Andrey; Morfill, Gregor; Molotkov, Vladimir; Usachev, Alexander; Zobnin, Andrey; Tarantik, Karl; Albrecht, Sebastian; Deysenroth, Christian; Rau, Christian; Mitic, Slobodan; Nosenko, Vladimir; Fink, Martin; Prof
Complex plasmas, a special case of dusty plasmas, are one of the most interesting physical objects to be studied under microgravity conditions. A way from dusty plasmas to complex plasmas was revealed when strong coupling phenomena in the dust subsystem were first theoretically predicted and then observed under ground laboratory conditions. Complex plasmas are, therefore, dusty plasmas, which are prepared intentionally to study generic phenomena of condensed matter physics. Complex plasmas have several advantages in this respect: Real-time, virtually undamped dynamics of the system can be resolved on the kinetic level, i.e. on the level of single microparticles. Under ground laboratory conditions the microparticles are strongly affected by the gravitational force, which has to be compensated by strong electrostatic forces. Therefore, the volume occupied by the microparticles is limited to sheath region. This makes formation of uniform 3D structures under ground condition almost impossible. Microgravity is therefore essential for studying 3D complex plasma systems. The next lab for complex plasma research under mug-conditions will be PK-4, a joint Russian-European project. The special feature of PK-4 (with respect to its predecessor PK-3 Plus on the ISS) is that it will allow to study the fluid phenomena. Geometry of the plasma chamber (a glass tube with the working part of about 200 mm long and 30 mm diameter) implies presence of micropaticle flows along its axis. A custom-made power supply will create either a DC or polarity-switched discharge inside the chamber filled with either neon or argon. In the DC mode the negatively-charged microparticles will drift opposite to the electric field. Polarity switching can be done with up to several kHz frequency, which will allow the discharge to change polarity, whereas heavy microparticles will be insensitive to such fast variations of the electric field. In this way, microparticles will be trapped inside the plasma chamber. For the diagnostics of the microparticles, two CCD cameras and an illumination laser sheet are available. Cameras and the laser focal plane are movable along the plasma chamber and cover almost the entire working area. Moving the laser sheet and cameras across the plasma chamber axis will allow to obtain information on the 3D structure of the microparticle clouds. Background plasma may be monitored by the so-called plasma glow camera, which produces three kaleidoscopic images of the plasma. Two of these images are filtered for two neon spectral lines and the third one represents the integral glow. Also, a spectrometer whose receiving optics is movable together with the cameras is available as a diagnostic means. Several microparticles manipulation techniques are implemented in PK-4, starting from simple discharge current modulation to using a powerful infrared laser exerting radiation pressure on microparticles. The experiment is going to be conducted on board of the International Space Station. The launch is scheduled to October 2014. Even before being launched into orbit, the PK-4 project already delivered lots of interesting scientific results, obtained in ground laboratory and parabolic flight experiments and numerical simulations. First of all, the kinetic model of the discharge was built and the discharge parameters, such as electron density and temperature, number density of metastable atoms were measured. Diagnostic methods are being further developed to be used on orbit. Then, the microscopic properties of the microparticles (i.e. their charge and forces acting on them) were determined using dynamic methods. Size dynamics (growth and etching) of microparticles in PK-4 discharges were studied. Collective plasma phenomena (such as e.g. dust-acoustic) waves were investigated. And, finally, the interdisciplinary experiments, making a link between the PK-4 plasmas and real condensed matter were conducted. Such phenomenon as electrorheology was successfully modelled with PK-4 complex plasmas in a parabolic flight. A review of the results and a roadmap for future orbital operations will be presented in this contribution.
Kubo, Shoji; Takemura, Shigekazu; Sakata, Chikaharu; Urata, Yorihisa; Nishioka, Takayoshi; Nozawa, Akinori; Kinoshita, Masahiko; Hamano, Genya; Nakanuma, Yasuni; Endo, Ginji
2014-01-01
A cholangiocarcinoma outbreak among workers of an offset color proof-printing department in a printing company was recently reported. It is important to understand the clinical course leading to occupational cholangiocarcinoma development for investigation of the carcinogenesis process and for surveillance and early detection. We evaluated the changes in laboratory test results and diagnostic imaging presentation before the detection of cholangiocarcinoma. We investigated the changes in laboratory test results and diagnostic imaging presentation before the detection of cholangiocarcinoma in 2 patients because the data were available. Results The clinical courses observed in the 2 participating patients showed persistent elevation of serum γ-glutamyl transpeptidase levels with or without elevated serum levels of alanine aminotransferase and/or aspartate aminotransferase before cholangiocarcinoma detection. Dilatation of the bile ducts without tumor-induced stenosis was observed several years before cholangiocarcinoma detection and progressed gradually in both patients. The serum concentration of carbohydrate 19-9 also increased prior to cholangiocarcinoma detection in both patients. Eventually, observation of stenosis of the bile duct and a space-occupying lesion strongly suggested cholangiocarcinoma. Pathological examination of the resected specimens showed chronic bile duct injury and neoplastic lesions, such as "biliary intraepithelial neoplasia" and "intraductal papillary neoplasm of the bile duct" in various sites of the bile ducts, particularly in the dilated bile ducts. The changes in laboratory test results and diagnostic imaging might be related to the development of cholangiocarcinoma. It is important to monitor diagnostic imaging presentation and laboratory test results in workers with extended exposure to organic solvents.
Alcalá, L; Reigadas, E; Marín, M; Martín, A; Catalán, P; Bouza, E
2015-08-01
A multicenter study of Clostridium difficile infection (CDI) performed during 2008 in Spain revealed that two of every three episodes went undiagnosed or were misdiagnosed owing to nonsensitive diagnostic tests or lack of clinical suspicion and request. Since then, efforts have been made to improve the diagnostic tests used by laboratories and to increase the awareness of this disease among both clinicians and microbiologists. Our objective was to evaluate the impact of these efforts by assessing the current magnitude of underdiagnosis of CDI in Spain using two point-prevalence studies performed on one day each in January and July of 2013. A total of 111 Spanish laboratories selected all unformed stool specimens received for microbiological diagnosis on these days, and toxigenic culture was performed at a central reference laboratory. Toxigenic isolates were characterized both pheno- and genotypically. The reference laboratory detected 103 episodes of CDI in patients aged 2 years or more. Half (50.5 %) of the episodes were not diagnosed in the participating laboratories, owing to insensitive diagnostic tests (15.5 %) or the lack of clinical suspicion and request (35.0 %). The main ribotypes were 014, 078/126, 001/072, and 106. Ribotype 027 caused 2.9 % of all cases. Despite all the interventions undertaken, CDI remains a highly neglected disease because of the lack of sensitive diagnostic tests in some institutions and, especially, the absence of clinical suspicion, mainly in patients with community-associated CDI. Toxigenic C. difficile should be routinely sought in unformed stools sent for microbiological diagnosis, regardless of their origin.
Chindamporn, Ariya; Chakrabarti, Arunaloke; Li, Ruoyu; Sun, Pei-Lun; Tan, Ban-Hock; Chua, Mitzi; Wahyuningsih, Retno; Patel, Atul; Liu, Zhengyin; Chen, Yee-Chun; Chayakulkeeree, Methee
2018-06-01
An online survey of mycology laboratories in seven Asian countries was conducted to assess the status, competence, and services available. Country representatives from the Asia Fungal Working Group (AFWG) contacted as many laboratories performing mycology diagnosis as possible in their respective countries, requesting that the laboratory heads complete the online survey. In total, 241 laboratories responded, including 71 in China, 104 in India, 11 in Indonesia, 26 in the Philippines, four in Singapore, 18 in Taiwan, and seven in Thailand. Overall, 129/241 (53.5%) surveyed mycology laboratories operate as separate designated mycology laboratories, 75/241 (31.1%) conduct regular formal staff training, 103/241 (42.7%) are accredited, and 88/157 (56.1%) participate in external quality assurance scheme (EQAS) programs. Microscopy and culture methods are available in nearly all laboratories, although few perform DNA sequencing (37/219; 16.9%) or use matrix-assisted laser desorption/ionization time-of-flight mass spectroscopy (MALDI-TOF MS) (27/219; 12.3%) for isolate identification. Antifungal susceptibility testing is performed in 142/241 (58.9%) laboratories, mainly for yeasts. The most commonly performed nonculture diagnostic is cryptococcal antigen testing (66 laboratories), followed by galactomannan testing (55), polymerase chain reaction (PCR) diagnosis (37), and beta-D-glucan testing (24). Therapeutic drug monitoring is conducted in 21 laboratories. There is almost no access to advanced diagnostic tests, like galactomannan, β-D-glucan, and PCR, in the surveyed laboratories in Indonesia, the Philippines, and Thailand. These results highlight the need for development of quality laboratories, accreditation and training of manpower in existing laboratories, and access to advanced non-culture-based diagnostic tests to facilitate the diagnosis of fungal infections in Asia.
NASA Astrophysics Data System (ADS)
Belov, M. Ye.; Shayko-Shaykovskiy, O. G.; Makhrova, Ye. G.; Kramar, V. M.; Oleksuik, I. S.
2018-01-01
We represent here the theoretical justifications, block scheme and experimental sample of a new automated complex "Thermodyn" for remote contactless diagnostics of inflammatory processes of the surfaces and in subcutaneous areas of human body. Also we described here the methods and results of diagnostic measurements, and results of practical applications of this complex.
Electricity-free amplification and detection for molecular point-of-care diagnosis of HIV-1.
Singleton, Jered; Osborn, Jennifer L; Lillis, Lorraine; Hawkins, Kenneth; Guelig, Dylan; Price, Will; Johns, Rachel; Ebels, Kelly; Boyle, David; Weigl, Bernhard; LaBarre, Paul
2014-01-01
In resource-limited settings, the lack of decentralized molecular diagnostic testing and sparse access to centralized medical facilities can present a critical barrier to timely diagnosis, treatment, and subsequent control and elimination of infectious diseases. Isothermal nucleic acid amplification methods, including reverse transcription loop-mediated isothermal amplification (RT-LAMP), are well-suited for decentralized point-of-care molecular testing in minimal infrastructure laboratories since they significantly reduce the complexity of equipment and power requirements. Despite reduced complexity, however, there is still a need for a constant heat source to enable isothermal nucleic acid amplification. This requirement poses significant challenges for laboratories in developing countries where electricity is often unreliable or unavailable. To address this need, we previously developed a low-cost, electricity-free heater using an exothermic reaction thermally coupled with a phase change material. This heater achieved acceptable performance, but exhibited considerable variability. Furthermore, as an enabling technology, the heater was an incomplete diagnostic solution. Here we describe a more precise, affordable, and robust heater design with thermal standard deviation <0.5°C at operating temperature, a cost of approximately US$.06 per test for heater reaction materials, and an ambient temperature operating range from 16°C to 30°C. We also pair the heater with nucleic acid lateral flow (NALF)-detection for a visual readout. To further illustrate the utility of the electricity-free heater and NALF-detection platform, we demonstrate sensitive and repeatable detection of HIV-1 with a ß-actin positive internal amplification control from processed sample to result in less than 80 minutes. Together, these elements are building blocks for an electricity-free platform capable of isothermal amplification and detection of a variety of pathogens.
Electricity-Free Amplification and Detection for Molecular Point-of-Care Diagnosis of HIV-1
Singleton, Jered; Osborn, Jennifer L.; Lillis, Lorraine; Hawkins, Kenneth; Guelig, Dylan; Price, Will; Johns, Rachel; Ebels, Kelly; Boyle, David; Weigl, Bernhard; LaBarre, Paul
2014-01-01
In resource-limited settings, the lack of decentralized molecular diagnostic testing and sparse access to centralized medical facilities can present a critical barrier to timely diagnosis, treatment, and subsequent control and elimination of infectious diseases. Isothermal nucleic acid amplification methods, including reverse transcription loop-mediated isothermal amplification (RT-LAMP), are well-suited for decentralized point-of-care molecular testing in minimal infrastructure laboratories since they significantly reduce the complexity of equipment and power requirements. Despite reduced complexity, however, there is still a need for a constant heat source to enable isothermal nucleic acid amplification. This requirement poses significant challenges for laboratories in developing countries where electricity is often unreliable or unavailable. To address this need, we previously developed a low-cost, electricity-free heater using an exothermic reaction thermally coupled with a phase change material. This heater achieved acceptable performance, but exhibited considerable variability. Furthermore, as an enabling technology, the heater was an incomplete diagnostic solution. Here we describe a more precise, affordable, and robust heater design with thermal standard deviation <0.5°C at operating temperature, a cost of approximately US$.06 per test for heater reaction materials, and an ambient temperature operating range from 16°C to 30°C. We also pair the heater with nucleic acid lateral flow (NALF)-detection for a visual readout. To further illustrate the utility of the electricity-free heater and NALF-detection platform, we demonstrate sensitive and repeatable detection of HIV-1 with a ß-actin positive internal amplification control from processed sample to result in less than 80 minutes. Together, these elements are building blocks for an electricity-free platform capable of isothermal amplification and detection of a variety of pathogens. PMID:25426953
Building Cross-Country Networks for Laboratory Capacity and Improvement.
Schneidman, Miriam; Matu, Martin; Nkengasong, John; Githui, Willie; Kalyesubula-Kibuuka, Simeon; Silva, Kelly Araujo
2018-03-01
Laboratory networks are vital to well-functioning public health systems and disease control efforts. Cross-country laboratory networks play a critical role in supporting epidemiologic surveillance, accelerating disease outbreak response, and tracking drug resistance. The East Africa Public Health Laboratory Network was established to bolster diagnostic and disease surveillance capacity. The network supports the introduction of regional quality standards; facilitates the rollout and evaluation of new diagnostic tools; and serves as a platform for training, research, and knowledge sharing. Participating facilities benefitted from state-of-the art investments, capacity building, and mentorship; conducted multicountry research studies; and contributed to disease outbreak response. Copyright © 2017 Elsevier Inc. All rights reserved.
[Mathematical model of technical equipment of a clinical-diagnostic laboratory].
Bukin, S I; Busygin, D V; Tilevich, M E
1990-01-01
The paper is concerned with the problems of technical equipment of standard clinico-diagnostic laboratories (CDL) in this country. The authors suggest a mathematic model that may minimize expenditures for laboratory studies. The model enables the following problems to be solved: to issue scientifically-based recommendations for technical equipment of CDL; to validate the medico-technical requirements for newly devised items; to select the optimum types of uniform items; to define optimal technical decisions at the stage of the design; to determine the lab assistant's labour productivity and the cost of some investigations; to compute the medical laboratory engineering requirement for treatment and prophylactic institutions of this country.
Grolla, A; Jones, S; Kobinger, G; Sprecher, A; Girard, G; Yao, M; Roth, C; Artsob, H; Feldmann, H; Strong, J E
2012-09-01
The mobile laboratory provides a safe, rapid and flexible platform to provide effective diagnosis of Ebola virus as well as additional differential diagnostic agents in remote settings of equatorial Africa. During the 2007 Democratic Republic of Congo outbreak of Ebola-Zaire, the mobile laboratory was set up in two different locations by two separate teams within a day of equipment arriving in each location. The first location was in Mweka where our laboratory took over the diagnostic laboratory space of the local hospital, whereas the second location, approximately 50 km south near Kampungu at the epicentre of the outbreak, required local labour to fabricate a tent structure as a suitable pre-existing structure was not available. In both settings, the laboratory was able to quickly set up, providing accurate and efficient molecular diagnostics (within 3 h of receiving samples) for 67 individuals, including four cases of Ebola, seven cases of Shigella and 13 cases of malaria. This rapid turn-around time provides an important role in the support of patient management and epidemiological surveillance. © 2012 Blackwell Verlag GmbH.
Thelaus, Johanna; Lindberg, Anna; Thisted Lambertz, Susanne; Byström, Mona; Forsman, Mats; Lindmark, Hans; Knutsson, Rickard; Båverud, Viveca; Bråve, Andreas; Jureen, Pontus; Lundin Zumpe, Annelie; Melefors, Öjar
The Swedish Forum for Biopreparedness Diagnostics (FBD) is a network that fosters collaboration among the 4 agencies with responsibility for the laboratory diagnostics of high-consequence pathogens, covering animal health and feed safety, food safety, public health and biodefense, and security. The aim of the network is to strengthen capabilities and capacities for diagnostics at the national biosafety level-3 (BSL-3) laboratories to improve Sweden's biopreparedness, in line with recommendations from the EU and WHO. Since forming in 2007, the FBD network has contributed to the harmonization of diagnostic methods, equipment, quality assurance protocols, and biosafety practices among the national BSL-3 laboratories. Lessons learned from the network include: (1) conducting joint projects with activities such as method development and validation, ring trials, exercises, and audits has helped to build trust and improve communication among participating agencies; (2) rotating the presidency of the network steering committee has fostered trust and commitment from all agencies involved; and (3) planning for the implementation of project outcomes is important to maintain gained competencies in the agencies over time. Contacts have now been established with national agencies of the other Nordic countries, with an aim to expanding the collaboration, broadening the network, finding synergies in new areas, strengthening the ability to share resources, and consolidating long-term financing in the context of harmonized European biopreparedness.
Lindberg, Anna; Thisted Lambertz, Susanne; Byström, Mona; Forsman, Mats; Lindmark, Hans; Knutsson, Rickard; Båverud, Viveca; Bråve, Andreas; Jureen, Pontus; Lundin Zumpe, Annelie; Melefors, Öjar
2017-01-01
The Swedish Forum for Biopreparedness Diagnostics (FBD) is a network that fosters collaboration among the 4 agencies with responsibility for the laboratory diagnostics of high-consequence pathogens, covering animal health and feed safety, food safety, public health and biodefense, and security. The aim of the network is to strengthen capabilities and capacities for diagnostics at the national biosafety level-3 (BSL-3) laboratories to improve Sweden's biopreparedness, in line with recommendations from the EU and WHO. Since forming in 2007, the FBD network has contributed to the harmonization of diagnostic methods, equipment, quality assurance protocols, and biosafety practices among the national BSL-3 laboratories. Lessons learned from the network include: (1) conducting joint projects with activities such as method development and validation, ring trials, exercises, and audits has helped to build trust and improve communication among participating agencies; (2) rotating the presidency of the network steering committee has fostered trust and commitment from all agencies involved; and (3) planning for the implementation of project outcomes is important to maintain gained competencies in the agencies over time. Contacts have now been established with national agencies of the other Nordic countries, with an aim to expanding the collaboration, broadening the network, finding synergies in new areas, strengthening the ability to share resources, and consolidating long-term financing in the context of harmonized European biopreparedness. PMID:28805472
Nikolac, Nora; Šupak-Smolčić, Vesna; Šimundić, Ana-Maria; Ćelap, Ivana
2013-01-01
Phlebotomy is one of the most complex medical procedures in the diagnosis, management and treatment of patients in healthcare. Since laboratory test results are the basis for a large proportion (60–80%) of medical decisions, any error in the phlebotomy process could have serious consequences. In order to minimize the possibility of errors, phlebotomy procedures should be standardised, well-documented and written instructions should be available at every workstation. Croatia is one of the few European countries that have national guidelines for phlebotomy, besides the universally used CLSI (Clinical Laboratory Standards Institute) H3-A6 Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; approved Standard-Sixth Edition (CLSI, 2007) and WHO (World Health Organization) guidelines on drawing blood: best practices in phlebotomy (WHO, 2010). However, the growing body of evidence in importance of preanalytical phase management resulted in a need for evidence based revision and expansion of existing recommendations. The Croatian Society for Medical Biochemistry and Laboratory Medicine, Working Group for the Preanalytical Phase issued this recommendation. This document is based on the CLSI guideline H3-A6, with significant differences and additional information. PMID:24266294
Nikolac, Nora; Supak-Smolcić, Vesna; Simundić, Ana-Maria; Celap, Ivana
2013-01-01
Phlebotomy is one of the most complex medical procedures in the diagnosis, management and treatment of patients in healthcare. Since laboratory test results are the basis for a large proportion (60-80%) of medical decisions, any error in the phlebotomy process could have serious consequences. In order to minimize the possibility of errors, phlebotomy procedures should be standardised, well-documented and written instructions should be available at every workstation. Croatia is one of the few European countries that have national guidelines for phlebotomy, besides the universally used CLSI (Clinical Laboratory Standards Institute) H3-A6 Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; approved Standard-Sixth Edition (CLSI, 2007) and WHO (World Health Organization) guidelines on drawing blood: best practices in phlebotomy (WHO, 2010). However, the growing body of evidence in importance of preanalytical phase management resulted in a need for evidence based revision and expansion of existing recommendations. The Croatian Society for Medical Biochemistry and Laboratory Medicine, Working Group for the Preanalytical Phase issued this recommendation. This document is based on the CLSI guideline H3-A6, with significant differences and additional information.
[Medical microbiology laboratories in Dutch hospitals: essential for safe patient care].
Bonten, M J M
2008-12-06
The Netherlands Health Care Inspectorate investigated the quality of medical microbiology laboratories in Dutch hospitals. By and large the laboratories fulfilled the requirements for appropriate care, although some processes were unsatisfactory and some were insufficiently formalised. In the Netherlands, laboratories for medical microbiology are integrated within hospitals and medical microbiologists are responsible for the diagnostic processes as well as for co-treatment of patients, infection prevention and research. This integrated model contrasts to the more industrialised model in many other countries, where such laboratories are physically distinct from hospitals with a strong focus on diagnostics. The Inspectorate also concludes that the current position of medical microbiology in Dutch hospitals is necessary for patient safety and that outsourcing of these facilities is considered unacceptable.
42 CFR 414.510 - Laboratory date of service for clinical laboratory and pathology specimens.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 3 2011-10-01 2011-10-01 false Laboratory date of service for clinical laboratory and pathology specimens. 414.510 Section 414.510 Public Health CENTERS FOR MEDICARE & MEDICAID... AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.510 Laboratory...
Clinically expedient reporting of rapid diagnostic test information.
Doern, G V
1986-03-01
With the development of rapid diagnostic tests in the clinical microbiology laboratory has come an awareness of the importance of rapid results reporting. Clearly, the potential clinical impact of rapid diagnostic tests is dependent on expeditious reporting. Traditional manual reporting systems are encumbered by the necessity of transcription of test information onto hard copy reports and then the subsequent distribution of such reports into the hands of the user. Laboratory computers when linked directly to CRTs located in nursing stations, ambulatory clinics, or physician's offices, both inside and outside of the hospital, permit essentially instantaneous transfer of test results from the laboratory to the clinician. Computer-assisted results reporting, while representing a significant advance over manual reporting systems is not, however, without problems. Concerns include validation of test information, authorization of users with access to test information, mechanical integrity, and cost. These issues notwithstanding, computerized results reporting will undoubtedly play a central role in optimizing the clinical impact of rapid diagnostic tests.
The cobas® 6800/8800 System: a new era of automation in molecular diagnostics.
Cobb, Bryan; Simon, Christian O; Stramer, Susan L; Body, Barbara; Mitchell, P Shawn; Reisch, Natasa; Stevens, Wendy; Carmona, Sergio; Katz, Louis; Will, Stephen; Liesenfeld, Oliver
2017-02-01
Molecular diagnostics is a key component of laboratory medicine. Here, the authors review key triggers of ever-increasing automation in nucleic acid amplification testing (NAAT) with a focus on specific automated Polymerase Chain Reaction (PCR) testing and platforms such as the recently launched cobas® 6800 and cobas® 8800 Systems. The benefits of such automation for different stakeholders including patients, clinicians, laboratory personnel, hospital administrators, payers, and manufacturers are described. Areas Covered: The authors describe how molecular diagnostics has achieved total laboratory automation over time, rivaling clinical chemistry to significantly improve testing efficiency. Finally, the authors discuss how advances in automation decrease the development time for new tests enabling clinicians to more readily provide test results. Expert Commentary: The advancements described enable complete diagnostic solutions whereby specific test results can be combined with relevant patient data sets to allow healthcare providers to deliver comprehensive clinical recommendations in multiple fields ranging from infectious disease to outbreak management and blood safety solutions.
Abdad, Mohammad Yazid; Squires, Raynal C; Cognat, Sebastien; Oxenford, Christopher John
2017-01-01
Arboviruses continue to pose serious public health threats in the World Health Organization (WHO) Western Pacific Region. As such, laboratories need to be equipped for their accurate detection. In 2011, to ensure test proficiency, the WHO Regional Office for the Western Pacific piloted an external quality assessment (EQA) programme for arbovirus diagnostics. By 2016, it had grown into a global programme with participation of 96 laboratories worldwide, including 25 laboratories from 19 countries, territories and areas in the Region. The test performance of the 25 laboratories in the Region in 2016 was high with 23 (92%) reporting correct results in all specimens for dengue and chikungunya viruses. For Zika virus, 18 (72%) of the 25 laboratories reported correct results in all specimens, while seven (28%) demonstrated at least one error. When comparing iterations of this EQA programme in the Region between 2013 and 2016, the number of participating laboratories increased from 18 to 25. The first round only included dengue virus, while the latest round additionally included chikungunya, Zika and yellow fever viruses. Proficiency for molecular detection of dengue virus remained high (83–94%) over the four-year period. The observed proficiency for arbovirus diagnostics between 2013 and 2016 is an indicator of laboratory quality improvement in the Region. PMID:29051839
Quality in the molecular microbiology laboratory.
Wallace, Paul S; MacKay, William G
2013-01-01
In the clinical microbiology laboratory advances in nucleic acid detection, quantification, and sequence analysis have led to considerable improvements in the diagnosis, management, and monitoring of infectious diseases. Molecular diagnostic methods are routinely used to make clinical decisions based on when and how to treat a patient as well as monitor the effectiveness of a therapeutic regime and identify any potential drug resistant strains that may impact on the long term patient treatment program. Therefore, confidence in the reliability of the result provided by the laboratory service to the clinician is essential for patient treatment. Hence, suitable quality assurance and quality control measures are important to ensure that the laboratory methods and service meet the necessary regulatory requirements both at the national and international level. In essence, the modern clinical microbiology laboratory ensures the appropriateness of its services through a quality management system that monitors all aspects of the laboratory service pre- and post-analytical-from patient sample receipt to reporting of results, from checking and upholding staff competency within the laboratory to identifying areas for quality improvements within the service offered. For most European based clinical microbiology laboratories this means following the common International Standard Organization (ISO9001) framework and ISO15189 which sets out the quality management requirements for the medical laboratory (BS EN ISO 15189 (2003) Medical laboratories-particular requirements for quality and competence. British Standards Institute, Bristol, UK). In the United States clinical laboratories performing human diagnostic tests are regulated by the Centers for Medicare and Medicaid Services (CMS) following the requirements within the Clinical Laboratory Improvement Amendments document 1988 (CLIA-88). This chapter focuses on the key quality assurance and quality control requirements within the modern microbiology laboratory providing molecular diagnostics.
Ruaño, Gualberto; Kocherla, Mohan; Graydon, James S; Holford, Theodore R; Makowski, Gregory S; Goethe, John W
2016-05-01
We describe a population genetic approach to compare samples interpreted with expert calling (EC) versus automated calling (AC) for CYP2D6 haplotyping. The analysis represents 4812 haplotype calls based on signal data generated by the Luminex xMap analyzers from 2406 patients referred to a high-complexity molecular diagnostics laboratory for CYP450 testing. DNA was extracted from buccal swabs. We compared the results of expert calls (EC) and automated calls (AC) with regard to haplotype number and frequency. The ratio of EC to AC was 1:3. Haplotype frequencies from EC and AC samples were convergent across haplotypes, and their distribution was not statistically different between the groups. Most duplications required EC, as only expansions with homozygous or hemizygous haplotypes could be automatedly called. High-complexity laboratories can offer equivalent interpretation to automated calling for non-expanded CYP2D6 loci, and superior interpretation for duplications. We have validated scientific expert calling specified by scoring rules as standard operating procedure integrated with an automated calling algorithm. The integration of EC with AC is a practical strategy for CYP2D6 clinical haplotyping. Copyright © 2016 Elsevier B.V. All rights reserved.
Clark, Andrew E; Kaleta, Erin J; Arora, Amit; Wolk, Donna M
2013-07-01
Within the past decade, clinical microbiology laboratories experienced revolutionary changes in the way in which microorganisms are identified, moving away from slow, traditional microbial identification algorithms toward rapid molecular methods and mass spectrometry (MS). Historically, MS was clinically utilized as a high-complexity method adapted for protein-centered analysis of samples in chemistry and hematology laboratories. Today, matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) MS is adapted for use in microbiology laboratories, where it serves as a paradigm-shifting, rapid, and robust method for accurate microbial identification. Multiple instrument platforms, marketed by well-established manufacturers, are beginning to displace automated phenotypic identification instruments and in some cases genetic sequence-based identification practices. This review summarizes the current position of MALDI-TOF MS in clinical research and in diagnostic clinical microbiology laboratories and serves as a primer to examine the "nuts and bolts" of MALDI-TOF MS, highlighting research associated with sample preparation, spectral analysis, and accuracy. Currently available MALDI-TOF MS hardware and software platforms that support the use of MALDI-TOF with direct and precultured specimens and integration of the technology into the laboratory workflow are also discussed. Finally, this review closes with a prospective view of the future of MALDI-TOF MS in the clinical microbiology laboratory to accelerate diagnosis and microbial identification to improve patient care.
Clark, Andrew E.; Kaleta, Erin J.; Arora, Amit
2013-01-01
SUMMARY Within the past decade, clinical microbiology laboratories experienced revolutionary changes in the way in which microorganisms are identified, moving away from slow, traditional microbial identification algorithms toward rapid molecular methods and mass spectrometry (MS). Historically, MS was clinically utilized as a high-complexity method adapted for protein-centered analysis of samples in chemistry and hematology laboratories. Today, matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) MS is adapted for use in microbiology laboratories, where it serves as a paradigm-shifting, rapid, and robust method for accurate microbial identification. Multiple instrument platforms, marketed by well-established manufacturers, are beginning to displace automated phenotypic identification instruments and in some cases genetic sequence-based identification practices. This review summarizes the current position of MALDI-TOF MS in clinical research and in diagnostic clinical microbiology laboratories and serves as a primer to examine the “nuts and bolts” of MALDI-TOF MS, highlighting research associated with sample preparation, spectral analysis, and accuracy. Currently available MALDI-TOF MS hardware and software platforms that support the use of MALDI-TOF with direct and precultured specimens and integration of the technology into the laboratory workflow are also discussed. Finally, this review closes with a prospective view of the future of MALDI-TOF MS in the clinical microbiology laboratory to accelerate diagnosis and microbial identification to improve patient care. PMID:23824373
42 CFR 419.2 - Basis of payment.
Code of Federal Regulations, 2012 CFR
2012-10-01
... prospective payment system establishes a national payment rate, standardized for geographic wage differences...) Capital-related costs; (9) Implantable items used in connection with diagnostic X-ray tests, diagnostic laboratory tests, and other diagnostic tests; (10) Durable medical equipment that is implantable; (11...
Particles and microfluidics merged: perspectives of highly sensitive diagnostic detection
Bale, Shyam Sundhar; Bhushan, Abhinav; Shen, Keyue; Seker, Erkin; Polyak, Boris
2014-01-01
There is a growing need for diagnostic technologies that provide laboratories with solutions that improve quality, enhance laboratory system productivity, and provide accurate detection of a broad range of infectious diseases and cancers. Recent advances in micro- and nanoscience and engineering, in particular in the areas of particles and microfluidic technologies, have advanced the “lab-on-a-chip” concept towards the development of a new generation of point-of-care diagnostic devices that could significantly enhance test sensitivity and speed. In this review, we will discuss many of the recent advances in microfluidics and particle technologies with an eye towards merging these two technologies for application in medical diagnostics. Although the potential diagnostic applications are virtually unlimited, the most important applications are foreseen in the areas of biomarker research, cancer diagnosis, and detection of infectious microorganisms. PMID:25378716
Concordance in diagnostic testing for respiratory pathogens of bighorn sheep
Walsh, Daniel P.; Cassirer, E. Frances; Bonds, Michael D.; Brown, Daniel R.; Edwards, William H.; Weiser, Glen C.; Drew, Mark L.; Briggs, Robert E.; Fox, Karen A.; Miller, Michael W.; Shanthalingam, Sudarvili; Srikumaran, Subramaniam; Besser, Thomas E.
2016-01-01
Reliable diagnostic tests are essential for disease investigation and management. This is particularly true for diseases of free-ranging wildlife where sampling is logistically difficult precluding retesting. Clinical assays for wildlife diseases frequently vary among laboratories because of lack of appropriate standardized commercial kits. Results of diagnostic testing may also be called into question when investigators report different etiologies for disease outbreaks, despite similar clinical and pathologic findings. To evaluate reliability of diagnostic testing for respiratory pathogens of bighorn sheep (Ovis canadensis), we conducted a series of ring tests across 6 laboratories routinely involved in detection of Mycoplasma ovipneumoniae, Pasteurellaceae, lktA (the Pasteurellaceae gene encoding leukotoxin), and 3 reference laboratories. Consistency of results for replicate samples within laboratories was high (median agreement = 1.0). Agreement between laboratories was high for polymerase chain reaction (PCR) detection of M. ovipneumoniae and culture isolation of Mannheimia spp. and Bibersteinia trehalosi(median agreement = 0.89–0.95, Kappa = 0.65–0.74), and lower for PCR detection of Mannheimiaspp. lktA (median agreement = 0.58, Kappa = 0.12). Most errors on defined status samples were false negatives, suggesting test sensitivity was a greater problem than specificity. However, tests for M. haemolytica and lktA yielded some false positive results. Despite differences in testing protocols, median agreement among laboratories and correct classification of controls for most agents was ≥0.80, meeting or exceeding the standard required by federal proficiency testing programs. This information is valuable for interpreting test results, laboratory quality assessments, and advancing diagnosis of respiratory disease in wild sheep. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.
Metagenomics: The Next Culture-Independent Game Changer
Forbes, Jessica D.; Knox, Natalie C.; Ronholm, Jennifer; Pagotto, Franco; Reimer, Aleisha
2017-01-01
A trend towards the abandonment of obtaining pure culture isolates in frontline laboratories is at a crossroads with the ability of public health agencies to perform their basic mandate of foodborne disease surveillance and response. The implementation of culture-independent diagnostic tests (CIDTs) including nucleic acid and antigen-based assays for acute gastroenteritis is leaving public health agencies without laboratory evidence to link clinical cases to each other and to food or environmental substances. This limits the efficacy of public health epidemiology and surveillance as well as outbreak detection and investigation. Foodborne outbreaks have the potential to remain undetected or have insufficient evidence to support source attribution and may inadvertently increase the incidence of foodborne diseases. Next-generation sequencing of pure culture isolates in clinical microbiology laboratories has the potential to revolutionize the fields of food safety and public health. Metagenomics and other ‘omics’ disciplines could provide the solution to a cultureless future in clinical microbiology, food safety and public health. Data mining of information obtained from metagenomics assays can be particularly useful for the identification of clinical causative agents or foodborne contamination, detection of AMR and/or virulence factors, in addition to providing high-resolution subtyping data. Thus, metagenomics assays may provide a universal test for clinical diagnostics, foodborne pathogen detection, subtyping and investigation. This information has the potential to reform the field of enteric disease diagnostics and surveillance and also infectious diseases as a whole. The aim of this review will be to present the current state of CIDTs in diagnostic and public health laboratories as they relate to foodborne illness and food safety. Moreover, we will also discuss the diagnostic and subtyping utility and concomitant bias limitations of metagenomics and comparable detection techniques in clinical microbiology, food and public health laboratories. Early advances in the discipline of metagenomics, however, have indicated noteworthy challenges. Through forthcoming improvements in sequencing technology and analytical pipelines among others, we anticipate that within the next decade, detection and characterization of pathogens via metagenomics-based workflows will be implemented in routine usage in diagnostic and public health laboratories. PMID:28725217
Validation of Metagenomic Next-Generation Sequencing Tests for Universal Pathogen Detection.
Schlaberg, Robert; Chiu, Charles Y; Miller, Steve; Procop, Gary W; Weinstock, George
2017-06-01
- Metagenomic sequencing can be used for detection of any pathogens using unbiased, shotgun next-generation sequencing (NGS), without the need for sequence-specific amplification. Proof-of-concept has been demonstrated in infectious disease outbreaks of unknown causes and in patients with suspected infections but negative results for conventional tests. Metagenomic NGS tests hold great promise to improve infectious disease diagnostics, especially in immunocompromised and critically ill patients. - To discuss challenges and provide example solutions for validating metagenomic pathogen detection tests in clinical laboratories. A summary of current regulatory requirements, largely based on prior guidance for NGS testing in constitutional genetics and oncology, is provided. - Examples from 2 separate validation studies are provided for steps from assay design, and validation of wet bench and bioinformatics protocols, to quality control and assurance. - Although laboratory and data analysis workflows are still complex, metagenomic NGS tests for infectious diseases are increasingly being validated in clinical laboratories. Many parallels exist to NGS tests in other fields. Nevertheless, specimen preparation, rapidly evolving data analysis algorithms, and incomplete reference sequence databases are idiosyncratic to the field of microbiology and often overlooked.
NASA Astrophysics Data System (ADS)
Borecki, M.; Prus, P.; Korwin-Pawlowski, M. L.; Rychlik, A.; Kozubel, W.
2017-08-01
Modern rims and wheels are tested at the design and production stages. Tests can be performed in laboratory conditions and on the ride. In the laboratory, complex and costly equipment is used, as for example wheel balancers and impact testers. Modern wheel balancers are equipped with electronic and electro-mechanical units that enable touch-less measurement of dimensions, including precision measurement of radial and lateral wheel run-out, automatic positioning and application of the counterweights, and vehicle wheel set monitoring - tread wear, drift angles and run-out unbalance. Those tests are performed by on-wheel axis measurements with laser distance meters. The impact tester enables dropping of weights from a defined height onto a wheel. Test criteria are the loss of pressure of the tire and generation of cracks in the wheel without direct impact of the falling weights. In the present paper, a set up composed of three accelerometers, a temperature sensor and a pressure sensor is examined as the base of a wheel tester. The sensor set-up configuration, on-line diagnostic and signal transmission are discussed.
Abbott, Daniel W; Friedman, Kenneth D; Karafin, Matthew S
2016-12-01
Thrombotic thrombocytopenic purpura (TTP) is a microangiopathic hemolytic anemia that requires emergent treatment with plasma exchange and is one of the most important conditions for which apheresis service professionals are consulted. Careful interpretation of initial laboratory values and the peripheral blood smear is a critical first step to determining the need for plasma exchange because other conditions can show deceptively similar red cell morphology, and ADAMTS13 levels are often not rapidly available. We report a case of a patient who was initially diagnosed with TTP and treated with plasma exchange based on preliminary laboratory data and a peripheral blood smear that contained bizarre microcytic red blood cells presumed to be schistocytes. The peripheral blood smear was later interpreted by the hematopathologist to be inconsistent with TTP, and further workup led to a diagnosis of severe vitamin B12 deficiency secondary to pernicious anemia. This case highlights the diagnostic complexity of thrombotic microangiopathies and the importance of a critical evaluation of the blood smear and presenting laboratory data when there is a concern for TTP. Copyright © 2016 Elsevier Ltd. All rights reserved.
The clinical chemistry and immunology of long-duration space missions.
Wu, A H; Taylor, G R; Graham, G A; McKinley, B A
1993-01-01
Clinical laboratory diagnostic capabilities are needed to guide health and medical care of astronauts during long-duration space missions. Clinical laboratory diagnostics, as defined for medical care on Earth, offers a model for space capabilities. Interpretation of laboratory results for health and medical care of humans in space requires knowledge of specific physiological adaptations that occur, primarily because of the absence of gravity, and how these adaptations affect reference values. Limited data from American and Russian missions have indicated shifts of intra- and extracellular fluids and electrolytes, changes in hormone concentrations related to fluid shifts and stresses of the missions, reductions in bone and muscle mass, and a blunting of the cellular immune response. These changes could increase susceptibility to space-related illness or injury during a mission and after return to Earth. We review physiological adaptations and the risk of medical problems that occur during space missions. We describe the need for laboratory diagnostics as a part of health and medical care in space, and how this capability might be delivered.
Tembuyser, Lien; Dequeker, Elisabeth M C
2016-01-01
Quality assurance is an indispensable element in a molecular diagnostic laboratory. The ultimate goal is to warrant patient safety. Several risks that can compromise high quality procedures are at stake, from sample collection to the test performed by the laboratory, the reporting of test results to clinicians, and the organization of effective external quality assessment schemes. Quality assurance should therefore be safeguarded at each level and should imply a holistic multidisciplinary approach. This review aims to provide an overview of good quality assurance practices and discusses certain risks and recommendations to promote and improve quality assurance for both diagnostic laboratories and for external quality assessment providers. The number of molecular targets is continuously rising, and new technologies are evolving. As this poses challenges for clinical implementation and increases the demand for external quality assessment, the formation of an international association for improving quality assurance in molecular pathology is called for.
Evidence of clinical utility: an unmet need in molecular diagnostics for patients with cancer.
Parkinson, David R; McCormack, Robert T; Keating, Susan M; Gutman, Steven I; Hamilton, Stanley R; Mansfield, Elizabeth A; Piper, Margaret A; Deverka, Patricia; Frueh, Felix W; Jessup, J Milburn; McShane, Lisa M; Tunis, Sean R; Sigman, Caroline C; Kelloff, Gary J
2014-03-15
This article defines and describes best practices for the academic and business community to generate evidence of clinical utility for cancer molecular diagnostic assays. Beyond analytical and clinical validation, successful demonstration of clinical utility involves developing sufficient evidence to demonstrate that a diagnostic test results in an improvement in patient outcomes. This discussion is complementary to theoretical frameworks described in previously published guidance and literature reports by the U.S. Food and Drug Administration, Centers for Disease Control and Prevention, Institute of Medicine, and Center for Medical Technology Policy, among others. These reports are comprehensive and specifically clarify appropriate clinical use, adoption, and payer reimbursement for assay manufacturers, as well as Clinical Laboratory Improvement Amendments-certified laboratories, including those that develop assays (laboratory developed tests). Practical criteria and steps for establishing clinical utility are crucial to subsequent decisions for reimbursement without which high-performing molecular diagnostics will have limited availability to patients with cancer and fail to translate scientific advances into high-quality and cost-effective cancer care. See all articles in this CCR Focus section, "The Precision Medicine Conundrum: Approaches to Companion Diagnostic Co-development." ©2014 AACR.
Recent advances in tuberculosis diagnostics in resource-limited settings.
Seki, Mitsuko; Kim, Chang-Ki; Hayakawa, Satoshi; Mitarai, Satoshi
2018-04-19
Smear-negative and drug-resistant cases of tuberculosis (TB) disease necessitate the development of new diagnostic methods, especially in resource-limited settings. To improve the current TB situations, sensitive and specific TB point-of-care tests (POCTs) should be developed. This review addresses the current status of TB, novel diagnostic methodologies for TB, and the impact of those new diagnostics on TB control in such situations. Moreover, the perspective of TB management based on laboratory examinations is described. Smear microscopy with sputum samples is the only laboratory examination available in many resource-limited settings and is still used globally. Several nucleic acid amplification tests (NATs) have been developed. The World Health Organization (WHO) endorsed novel diagnostics based on NATs and updated their definition of a bacteriologically confirmed case requiring the biological specimen to be positive by smear microscopy, culture, or the WHO-recommended rapid diagnostic protocols. The use of new diagnostics increased the number of bacteriologically confirmed TB cases. Novel diagnostics are now available, but their sensitivity is still lower than that of conventional liquid culture method. To address the increasing incidence of TB, more resources including novel diagnostics as POCTs with higher sensitivity must be allocated to healthcare systems.
Point-of-care diagnostics for niche applications.
Cummins, Brian M; Ligler, Frances S; Walker, Glenn M
2016-01-01
Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. Copyright © 2016 Elsevier Inc. All rights reserved.
Diagnosing Appendicitis: Evidence-Based Review of the Diagnostic Approach in 2014
Shogilev, Daniel J.; Duus, Nicolaj; Odom, Stephen R.; Shapiro, Nathan I.
2014-01-01
Introduction Acute appendicitis is the most common abdominal emergency requiring emergency surgery. However, the diagnosis is often challenging and the decision to operate, observe or further work-up a patient is often unclear. The utility of clinical scoring systems (namely the Alvarado score), laboratory markers, and the development of novel markers in the diagnosis of appendicitis remains controversial. This article presents an update on the diagnostic approach to appendicitis through an evidence-based review. Methods We performed a broad Medline search of radiological imaging, the Alvarado score, common laboratory markers, and novel markers in patients with suspected appendicitis. Results Computed tomography (CT) is the most accurate mode of imaging for suspected cases of appendicitis, but the associated increase in radiation exposure is problematic. The Alvarado score is a clinical scoring system that is used to predict the likelihood of appendicitis based on signs, symptoms and laboratory data. It can help risk stratify patients with suspected appendicitis and potentially decrease the use of CT imaging in patients with certain Alvarado scores. White blood cell (WBC), C-reactive protein (CRP), granulocyte count and proportion of polymorphonuclear (PMN) cells are frequently elevated in patients with appendicitis, but are insufficient on their own as a diagnostic modality. When multiple markers are used in combination their diagnostic utility is greatly increased. Several novel markers have been proposed to aid in the diagnosis of appendicitis; however, while promising, most are only in the preliminary stages of being studied. Conclusion While CT is the most accurate mode of imaging in suspected appendicitis, the accompanying radiation is a concern. Ultrasound may help in the diagnosis while decreasing the need for CT in certain circumstances. The Alvarado Score has good diagnostic utility at specific cutoff points. Laboratory markers have very limited diagnostic utility on their own but show promise when used in combination. Further studies are warranted for laboratory markers in combination and to validate potential novel markers. PMID:25493136
Glucose-6-phosphate dehydrogenase laboratory assay: How, when, and why?
Minucci, Angelo; Giardina, Bruno; Zuppi, Cecilia; Capoluongo, Ettore
2009-01-01
Glucose 6-phosphate dehydrogenase (G6PD) deficiency is the most common defect of red blood cells. Although some different laboratory techniques or methods are employed for the biochemical screening, a strict relationship between biochemists, clinicians, and molecular biologists is necessary for a definitive diagnosis. This article represents an overview on the current laboratory tests finalized to the screening or to the definitive diagnosis of G6PD-deficiency, underlying the problems regarding the biochemical and molecular identification of heterozygote females other than those regarding the standardization of the clinical and laboratory diagnostic procedures. Finally, this review is aimed to give a flow-chart for the complete diagnostic approach of G6PD-deficiency.
Laboratory Spectroscopy of Astrophysically-Relevant Materials: Developing Dust as a Diagnostic
NASA Technical Reports Server (NTRS)
Rinehart, Stephen A.
2010-01-01
Over forty years ago, observations in the new field of infrared astronomy showed a broad spectral feature at 10 microns; the feature was quickly associated with the presence of silicate-rich dust. Since that time, improvements in infrared astronomy have led to the discovery of a plethora of additional spectral features attributable to dust. By combining these observations with spectroscopic data acquired in the laboratory, astronomers have a diagnostic tool that can be used to explore underlying astronomical phenomena. As the laboratory data improves, so does our ability to interpret the astronomical observations. Here, we discuss some recent progress in laboratory spectroscopy and attempt to identify future research directions.
South African Ebola diagnostic response in Sierra Leone: A modular high biosafety field laboratory
Jansen van Vuren, Petrus; Meier, Gunther H.; le Roux, Chantel; Conteh, Ousman S.; Kemp, Alan; Fourie, Cardia; Naidoo, Prabha; Naicker, Serisha; Ohaebosim, Phumza; Storm, Nadia; Hellferscee, Orienka; Ming Sun, Lisa K.; Mogodi, Busisiwe; Prabdial-Sing, Nishi; du Plessis, Desiree; Greyling, Deidre; Loubser, Shayne; Goosen, Mark; McCulloch, Stewart D.; Scott, Terence P.; Moerdyk, Alexandra; Dlamini, Wesley; Konneh, Kelfala; Kamara, Idrissa L.; Sowa, Dauda; Sorie, Samuel; Kargbo, Brima; Madhi, Shabir A.
2017-01-01
Background In August 2014, the National Institute for Communicable Diseases (NICD) in South Africa established a modular high-biosafety field Ebola diagnostic laboratory (SA FEDL) near Freetown, Sierra Leone in response to the rapidly increasing number of Ebola virus disease (EVD) cases. Methods and findings The SA FEDL operated in the Western Area of Sierra Leone, which remained a “hotspot” of the EVD epidemic for months. The FEDL was the only diagnostic capacity available to respond to the overwhelming demand for rapid EVD laboratory diagnosis for several weeks in the initial stages of the EVD crisis in the capital of Sierra Leone. Furthermore, the NICD set out to establish local capacity amongst Sierra Leonean nationals in all aspects of the FEDL functions from the outset. This led to the successful hand-over of the FEDL to the Sierra Leone Ministry of Health and Sanitation in March 2015. Between 25 August 2014 and 22 June 2016, the laboratory tested 11,250 specimens mostly from the Western Urban and Western Rural regions of Sierra Leone, of which 2,379 (21.14%) tested positive for Ebola virus RNA. Conclusions The bio-safety standards and the portability of the SA FEDL, offered a cost-effective and practical alternative for the rapid deployment of a field-operated high biocontainment facility. The SA FEDL teams demonstrated that it is highly beneficial to train the national staff in the course of formidable disease outbreak and accomplished their full integration into all operational and diagnostic aspects of the laboratory. This initiative contributed to the international efforts in bringing the EVD outbreak under control in Sierra Leone, as well as capacitating local African scientists and technologists to respond to diagnostic needs that might be required in future outbreaks of highly contagious pathogens. PMID:28628619
South African Ebola diagnostic response in Sierra Leone: A modular high biosafety field laboratory.
Paweska, Janusz T; Jansen van Vuren, Petrus; Meier, Gunther H; le Roux, Chantel; Conteh, Ousman S; Kemp, Alan; Fourie, Cardia; Naidoo, Prabha; Naicker, Serisha; Ohaebosim, Phumza; Storm, Nadia; Hellferscee, Orienka; Ming Sun, Lisa K; Mogodi, Busisiwe; Prabdial-Sing, Nishi; du Plessis, Desiree; Greyling, Deidre; Loubser, Shayne; Goosen, Mark; McCulloch, Stewart D; Scott, Terence P; Moerdyk, Alexandra; Dlamini, Wesley; Konneh, Kelfala; Kamara, Idrissa L; Sowa, Dauda; Sorie, Samuel; Kargbo, Brima; Madhi, Shabir A
2017-06-01
In August 2014, the National Institute for Communicable Diseases (NICD) in South Africa established a modular high-biosafety field Ebola diagnostic laboratory (SA FEDL) near Freetown, Sierra Leone in response to the rapidly increasing number of Ebola virus disease (EVD) cases. The SA FEDL operated in the Western Area of Sierra Leone, which remained a "hotspot" of the EVD epidemic for months. The FEDL was the only diagnostic capacity available to respond to the overwhelming demand for rapid EVD laboratory diagnosis for several weeks in the initial stages of the EVD crisis in the capital of Sierra Leone. Furthermore, the NICD set out to establish local capacity amongst Sierra Leonean nationals in all aspects of the FEDL functions from the outset. This led to the successful hand-over of the FEDL to the Sierra Leone Ministry of Health and Sanitation in March 2015. Between 25 August 2014 and 22 June 2016, the laboratory tested 11,250 specimens mostly from the Western Urban and Western Rural regions of Sierra Leone, of which 2,379 (21.14%) tested positive for Ebola virus RNA. The bio-safety standards and the portability of the SA FEDL, offered a cost-effective and practical alternative for the rapid deployment of a field-operated high biocontainment facility. The SA FEDL teams demonstrated that it is highly beneficial to train the national staff in the course of formidable disease outbreak and accomplished their full integration into all operational and diagnostic aspects of the laboratory. This initiative contributed to the international efforts in bringing the EVD outbreak under control in Sierra Leone, as well as capacitating local African scientists and technologists to respond to diagnostic needs that might be required in future outbreaks of highly contagious pathogens.
[The current clinical laboratory in the public health system and medical science: a lecture].
Men'shikov, V V
2011-11-01
The analytic and diagnostic possibilities of current clinical laboratories are discussed. The roles of laboratory information in the formation of new research directions are characterized. The proposals on the development of economic basics of the development of laboratory medicine.
Vola, Ambra; Tamarozzi, Francesca; Noordin, Rahmah; Yunus, Muhammad Hafiznur; Khanbabaie, Sam; De Silvestri, Annalisa; Brunetti, Enrico; Mariconti, Mara
2018-04-14
Rapid diagnostic tests for cystic echinococcosis (CE) are convenient to support ultrasound diagnosis in uncertain cases, especially in resource-limited settings. We found comparable diagnostic performances of the experimental Hyd Rapid Test and the commercial VIRapid HYDATIDOSIS Test, used in our diagnostic laboratory, using samples from well-characterized hepatic CE cases. Copyright © 2018 Elsevier Inc. All rights reserved.
42 CFR 419.2 - Basis of payment.
Code of Federal Regulations, 2013 CFR
2013-10-01
... prospective payment system establishes a national payment rate, standardized for geographic wage differences... X-ray tests, diagnostic laboratory tests, and other diagnostic tests; (10) Durable medical equipment...
Zachar, Erin K; Burgess, Hilary J; Wobeser, Bruce K
2016-06-01
Fine-needle aspiration (FNA) is commonly used to diagnose skin disease in companion animals, but its use in horses appears to be infrequent. Equine veterinarians in western Canada were surveyed to determine their opinions about FNA and 15 years of diagnostic submissions were used to compare the perceived to actual value of FNA in the diagnosis of skin disease in horses. Practitioners viewed FNA as quick, easy, economical, and minimally invasive. However, most veterinarians rarely chose to use FNA due to a perception that sample quality and diagnostic yield were poor and there was a narrow range of diseases the technique could diagnose. Analysis of the FNA cytology samples from a veterinary diagnostic laboratory showed a wide variety of equine skin disease conditions, but the frequency of non-diagnostic results was significantly higher in equine submissions compared to those from dogs and cats.
Schlaberg, Robert; Mitchell, Michael J; Taggart, Edward W; She, Rosemary C
2012-01-01
US Food and Drug Administration (FDA)-approved diagnostic tests based on molecular genetic technologies are becoming available for an increasing number of microbial pathogens. Advances in technology and lower costs have moved molecular diagnostic tests formerly performed for research purposes only into much wider use in clinical microbiology laboratories. To provide an example of laboratory studies performed to verify the performance of an FDA-approved assay for the detection of Clostridium difficile cytotoxin B compared with the manufacturer's performance standards. We describe the process and protocols used by a laboratory for verification of an FDA-approved assay, assess data from the verification studies, and implement the assay after verification. Performance data from the verification studies conducted by the laboratory were consistent with the manufacturer's performance standards and the assay was implemented into the laboratory's test menu. Verification studies are required for FDA-approved diagnostic assays prior to use in patient care. Laboratories should develop a standardized approach to verification studies that can be adapted and applied to different types of assays. We describe the verification of an FDA-approved real-time polymerase chain reaction assay for the detection of a toxin gene in a bacterial pathogen.
Giordano, P C
2013-10-01
The consistent multi-ethnic migrations of the last decades have considerably changed the epidemiology of the hemoglobinopathies. Healthy carriers of these conditions are present today in many nonendemic parts of the world, and severely affected children are now born where these diseases were previously rare or unknown. Improving the competence in carrier diagnostics at the laboratory level is one of the first concerns when introducing management and primary prevention of the severe conditions in nonendemic areas. This review describes how and when carriers should be correctly diagnosed and informed. The essential technologies needed for basic carrier diagnostics in different situations are summarized in some detail, and interpretation of the results and a number of related problems are discussed. The role of the hematology laboratory is essential, particularly in nonendemic areas where the first line of health care is often insufficiently aware of hemoglobinopathy management. Carriers living in nonendemic areas can be appropriately diagnosed and informed regarding genetic risk and prevention by well-organized laboratories. Both basic and specialized diagnostics are needed for the correct treatment for the anemic carriers, for primary prevention in couples at risk and for state-of-the art care of severely affected patients. © 2012 John Wiley & Sons Ltd.
Federal Register 2010, 2011, 2012, 2013, 2014
2015-08-03
...] Promoting Semantic Interoperability of Laboratory Data; Public Workshop; Request for Comments AGENCY: Food... workshop entitled ``FDA/CDC/NLM Workshop on Promoting Semantic Interoperability of Laboratory Data.'' The... to promoting the semantic interoperability of laboratory data between in vitro diagnostic devices and...
Nash, Kevin A.; Wallace, Richard J.
2012-01-01
Summary: Within the past 10 years, treatment and diagnostic guidelines for nontuberculous mycobacteria have been recommended by the American Thoracic Society (ATS) and the Infectious Diseases Society of America (IDSA). Moreover, the Clinical and Laboratory Standards Institute (CLSI) has published and recently (in 2011) updated recommendations including suggested antimicrobial and susceptibility breakpoints. The CLSI has also recommended the broth microdilution method as the gold standard for laboratories performing antimicrobial susceptibility testing of nontuberculous mycobacteria. This article reviews the laboratory, diagnostic, and treatment guidelines together with established and probable drug resistance mechanisms of the nontuberculous mycobacteria. PMID:22763637
Laboratory Diagnosis of Congenital Toxoplasmosis
Pomares, Christelle
2016-01-01
Recent studies have demonstrated that screening and treatment for toxoplasmosis during gestation result in a decrease of vertical transmission and clinical sequelae. Early treatment was associated with improved outcomes. Thus, laboratory methods should aim for early identification of infants with congenital toxoplasmosis (CT). Diagnostic approaches should include, at least, detection of Toxoplasma IgG, IgM, and IgA and a comprehensive review of maternal history, including the gestational age at which the mother was infected and treatment. Here, we review laboratory methods for the diagnosis of CT, with emphasis on serological tools. A diagnostic algorithm that takes into account maternal history is presented. PMID:27147724
Ekawati, Lenny L; Herdiana, Herdiana; Sumiwi, Maria E; Barussanah, Cut; Ainun, Cut; Sabri, Sabri; Maulana, Teuku; Rahmadyani, Rahmadyani; Maneh, Cut; Yani, Muhammad; Valenti, Paola; Elyazar, Iqbal R F; Hawley, William A
2015-06-11
The Health Office of Aceh aims to eliminate malaria from Aceh Province, Indonesia by 2015. Malaria was formerly common in Aceh (population 4.5 million), but has declined dramatically in recent years consequent to post-tsunami control efforts. Successful elimination will depend upon rapid and accurate diagnosis and case follow-up at community level. A prerequisite to this is widespread coverage of high quality malaria diagnosis. This study describes the results of a comprehensive assessment of the malaria diagnostic capacity in Aceh as the province moves towards malaria elimination. The study was conducted in 23 districts in Aceh from October 2010 to July 2011. Six types of questionnaires were used to collect data on competency of microscopists and laboratory capacity. Standardized slides were used to evaluate the proficiency of all microscopists. In addition, site visits to 17 primary health centres (PHC) assessed diagnostic practice and logistics capacity. Five hundred and seventy four malaria microscopists have been officially registered and assigned to duty in the 23 districts in Aceh Province. They work in 345 laboratories, predominantly in PHCs (69 %) and hospitals (25 %). Three laboratories were evaluated as adequate for all 30 elements, while 29 laboratories were adequate for less than five of 30 elements. Standardized proficiency tests showed that 413 microscopists were at basic (in training) level, with 10 advanced and 9 reference level. No microscopist achieved expert level. Neither the province nor any of Aceh's districts has a standardized inventory and logistics database for malaria diagnostics, nor did any of the surveyed laboratories operate a quality assurance programme for either microscopy or rapid diagnostic tests. The study highlights the importance of careful assessment of diagnostic capacity when embarking upon a large-scale malaria elimination programme. Aceh's laboratories have minimal infrastructure with nearly all microscopists still in training. On the positive side, a large workforce of microscopists has been assigned to laboratories with the needed equipment. Aceh will need to embark on a large-scale comprehensive quality assurance scheme if it is to achieve malaria elimination.
Diagnostic microbiology in veterinary dermatology: present and future.
Guardabassi, Luca; Damborg, Peter; Stamm, Ivonne; Kopp, Peter A; Broens, Els M; Toutain, Pierre-Louis
2017-02-01
The microbiology laboratory can be perceived as a service provider rather than an integral part of the healthcare team. The aim of this review is to discuss the current challenges of providing a state-of-the-art diagnostic veterinary microbiology service including the identification (ID) and antimicrobial susceptibility testing (AST) of key pathogens in veterinary dermatology. The Study Group for Veterinary Microbiology (ESGVM) of the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) identified scientific, technological, educational and regulatory issues impacting the predictive value of AST and the quality of the service offered by microbiology laboratories. The advent of mass spectrometry has significantly reduced the time required for ID of key pathogens such as Staphylococcus pseudintermedius. However, the turnaround time for validated AST methods has remained unchanged for many years. Beyond scientific and technological constraints, AST methods are not harmonized and clinical breakpoints for some antimicrobial drugs are either missing or inadequate. Small laboratories, including in-clinic laboratories, are usually not adequately equipped to run up-to-date clinical microbiologic diagnostic tests. ESGVM recommends the use of laboratories employing mass spectrometry for ID and broth micro-dilution for AST, and offering assistance by expert microbiologists on pre- and post-analytical issues. Setting general standards for veterinary clinical microbiology, promoting antimicrobial stewardship, and the development of new, validated and rapid diagnostic methods, especially for AST, are among the missions of ESGVM. © 2017 The Authors. Veterinary Dermatology published by John Wiley & Sons Ltd on behalf of the ESVD and ACVD.
Montoya, Pablo J.; Lukehart, Sheila A.; Brentlinger, Paula E.; Blanco, Ana J.; Floriano, Florencia; Sairosse, Josefa; Gloyd, Stephen
2006-01-01
OBJECTIVE: Programmes to control syphilis in developing countries are hampered by a lack of laboratory services, delayed diagnosis, and doubts about current screening methods. We aimed to compare the diagnostic accuracy of an immunochromatographic strip (ICS) test and the rapid plasma reagin (RPR) test with the combined gold standard (RPR, Treponema pallidum haemagglutination assay and direct immunofluorescence stain done at a reference laboratory) for the detection of syphilis in pregnancy. METHODS: We included test results from 4789 women attending their first antenatal visit at one of six health facilities in Sofala Province, central Mozambique. We compared diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of ICS and RPR done at the health facilities and ICS performed at the reference laboratory. We also made subgroup comparisons by human immunodeficiency virus (HIV) and malaria status. FINDINGS: For active syphilis, the sensitivity of the ICS was 95.3% at the reference laboratory, and 84.1% at the health facility. The sensitivity of the RPR at the health facility was 70.7%. Specificity and positive and negative predictive values showed a similar pattern. The ICS outperformed RPR in all comparisons (P<0.001). CONCLUSION: The diagnostic accuracy of the ICS compared favourably with that of the gold standard. The use of the ICS in Mozambique and similar settings may improve the diagnosis of syphilis in health facilities, both with and without laboratories. PMID:16501726
Introduction of the Bethesda System to Mainland China with a Web-based tutorial.
Yuan, Qin; Chang, Alexander Russell; Ng, Ho Keung
2003-01-01
To validate the use of a Web-based tutorial to introduce the Bethesda System (TBS) to Mainland Chinese laboratories. Digitized color images of the diagnostic features in 20 Pap smears were displayed on a Web page. Participants were asked to give each smear a diagnosis using the reporting nomenclature employed in their laboratory or one that was familiar to them. This was followed by teaching images of each smear accompanied by text in English and Chinese that highlighted important features for making a diagnosis using TBS. Participants then reviewed the 20 original Pap smears and rendered a diagnosis using TBS. Pathologists and cytotechnologists at 17 laboratories located in 10 cities completed the exercise. The average diagnostic accuracy for the 20 Pap smears before and after the tutorial was 76% and 88%, respectively. Web-based tutorials can be used for disseminating cytologic information to widely dispersed laboratories in China and help enhance the practice of cytology, currently an underutilized diagnostic technique. However, such difficulties as lack of Internet connections in the laboratory, outdated computers and a lack of interest in cytology need to be overcome to ensure success.
2013-01-01
Background Human leukocyte antigen matching at allelic resolution is proven clinically significant in hematopoietic stem cell transplantation, lowering the risk of graft-versus-host disease and mortality. However, due to the ever growing HLA allele database, tissue typing laboratories face substantial challenges. In light of the complexity and the high degree of allelic diversity, it has become increasingly difficult to define the classical transplantation antigens at high-resolution by using well-tried methods. Thus, next-generation sequencing is entering into diagnostic laboratories at the perfect time and serving as a promising tool to overcome intrinsic HLA typing problems. Therefore, we have developed and validated a scalable automated HLA class I and class II typing approach suitable for diagnostic use. Results A validation panel of 173 clinical and proficiency testing samples was analysed, demonstrating 100% concordance to the reference method. From a total of 1,273 loci we were able to generate 1,241 (97.3%) initial successful typings. The mean ambiguity reduction for the analysed loci was 93.5%. Allele assignment including intronic sequences showed an improved resolution (99.2%) of non-expressed HLA alleles. Conclusion We provide a powerful HLA typing protocol offering a short turnaround time of only two days, a fully integrated workflow and most importantly a high degree of typing reliability. The presented automated assay is flexible and can be scaled by specific primer compilations and the use of different 454 sequencing systems. The workflow was successfully validated according to the policies of the European Federation for Immunogenetics. Next-generation sequencing seems to become one of the new methods in the field of Histocompatibility. PMID:23557197
Tohyama, K
2018-05-01
The Japanese Society for Laboratory Hematology (JSLH) was launched in 2000 and has been developed by a mutual collaboration of hematologists, medical technologists, and the companies involved in hematological laboratory testing. The aim of JSLH is the progress and development of laboratory hematology by academic conferences, periodic publication of academic journal, training and education (in the meeting, the journal, or the website), promotion of the standardization of laboratory hematology, and certification of the laboratory hematology specialists. Among 3 specialized committees organized for the standardization of laboratory hematology, the standardization committee on blood cell morphology has been dealing with the various projects on peripheral/bone marrow blood cells and normal/abnormal morphology. Another independent organization, the Japanese National Research Group on idiopathic bone marrow failure syndromes (BMF), has raised the importance of the dysplasia of myelodysplastic syndromes (MDS) and has been conducting the prospective registration, central review, and follow-up study of MDS. This group recently proposed the grading system for diagnostic accuracy of MDS, and the detailed procedure of morphological diagnosis of MDS is presented in the specialized color atlas with typical photographs of various dysplasia. JSLH has also approved the grading system for diagnostic accuracy of MDS and adopted this standardized diagnostic system to the educational item for certification of the laboratory hematology specialists, aiming at a nationwidely expanding morphological evaluation of myelodysplasia. Further and significant progress in the standardization of blood cell morphology will be expected in Japan through the activity of JSLH. © 2018 John Wiley & Sons Ltd.
Efficacy of a Virtual Teaching Assistant in an Open Laboratory Environment for Electric Circuits
ERIC Educational Resources Information Center
Saleheen, Firdous; Wang, Zicong; Picone, Joseph; Butz, Brian P.; Won, Chang-Hee
2018-01-01
In order to provide an on-demand, open electrical engineering laboratory, we developed an innovative software-based Virtual Open Laboratory Teaching Assistant (VOLTA). This web-based virtual assistant provides laboratory instructions, equipment usage videos, circuit simulation assistance, and hardware implementation diagnostics. VOLTA allows…
Udager, Aaron M; Alva, Ajjai; Mehra, Rohit
2014-01-01
The idea that detailed knowledge of molecular oncogenesis will drive diagnostic, prognostic, and therapeutic clinical decision making in an increasingly multidisciplinary practice of oncologic care has been anticipated for many years. With the recent rapid advancement in our understanding of the molecular underpinnings of genitourinary malignancies, this concept is now starting to take shape in the fields of prostate, kidney, bladder, testicular, and penile cancer. Such breakthroughs necessitate the development of robust clinical-grade assays that can be quickly made available for patients to facilitate diagnosis in challenging cases, risk-stratify patients for subsequent clinical management, select the appropriate targeted therapy from among increasingly diverse and numerous options, and enroll patients in advanced clinical trials. This rapid translation of basic and clinical cancer research requires a streamlined, multidisciplinary approach to clinical assay development, termed here the molecular diagnostics service line laboratory. In this review, we summarize the current state and explore the future of molecular diagnostics in genitourinary oncology to conceptualize a genitourinary service line laboratory at a tertiary clinical institution.
Wong, Joyce Y P; Chin, David; Fung, Henry; Li, Ann; Wong, Marcus M S; Kwok, Henry K H
2014-01-01
Upper limb musculoskeletal complaints are common among certain health professionals. We report two cases, both involving technicians working in a diagnostic tuberculosis laboratory in Hong Kong. A work process evaluation suggest that the need to repeatedly open and close small bottles, as well as to work for prolonged periods of time in confined areas, could be related to the workers' clinical presentation. The cases are also compatible with the diagnosis of repetitive strain injury (RSI) of the upper limb, but this term is not commonly used nowadays because of various definitional issues. A review of the various diagnostic issues in RSI is presented.
Laboratory hemostasis: milestones in Clinical Chemistry and Laboratory Medicine.
Lippi, Giuseppe; Favaloro, Emmanuel J
2013-01-01
Hemostasis is a delicate, dynamic and intricate system, in which pro- and anti-coagulant forces cooperate for either maintaining blood fluidity under normal conditions, or else will prompt blood clot generation to limit the bleeding when the integrity of blood vessels is jeopardized. Excessive prevalence of anticoagulant forces leads to hemorrhage, whereas excessive activation of procoagulant forces triggers excessive coagulation and thrombosis. The hemostasis laboratory performs a variety of first, second and third line tests, and plays a pivotal role in diagnostic and monitoring of most hemostasis disturbances. Since the leading targets of Clinical Chemistry and Laboratory Medicine include promotion of progress in fundamental and applied research, along with publication of guidelines and recommendations in laboratory diagnostics, this journal is an ideal source of information on current developments in the laboratory technology of hemostasis, and this article is aimed to celebrate some of the most important and popular articles ever published by the journal in the filed of laboratory hemostasis.
Hong, Na; Li, Dingcheng; Yu, Yue; Xiu, Qiongying; Liu, Hongfang; Jiang, Guoqian
2016-10-01
Constructing standard and computable clinical diagnostic criteria is an important but challenging research field in the clinical informatics community. The Quality Data Model (QDM) is emerging as a promising information model for standardizing clinical diagnostic criteria. To develop and evaluate automated methods for converting textual clinical diagnostic criteria in a structured format using QDM. We used a clinical Natural Language Processing (NLP) tool known as cTAKES to detect sentences and annotate events in diagnostic criteria. We developed a rule-based approach for assigning the QDM datatype(s) to an individual criterion, whereas we invoked a machine learning algorithm based on the Conditional Random Fields (CRFs) for annotating attributes belonging to each particular QDM datatype. We manually developed an annotated corpus as the gold standard and used standard measures (precision, recall and f-measure) for the performance evaluation. We harvested 267 individual criteria with the datatypes of Symptom and Laboratory Test from 63 textual diagnostic criteria. We manually annotated attributes and values in 142 individual Laboratory Test criteria. The average performance of our rule-based approach was 0.84 of precision, 0.86 of recall, and 0.85 of f-measure; the performance of CRFs-based classification was 0.95 of precision, 0.88 of recall and 0.91 of f-measure. We also implemented a web-based tool that automatically translates textual Laboratory Test criteria into the QDM XML template format. The results indicated that our approaches leveraging cTAKES and CRFs are effective in facilitating diagnostic criteria annotation and classification. Our NLP-based computational framework is a feasible and useful solution in developing diagnostic criteria representation and computerization. Copyright © 2016 Elsevier Inc. All rights reserved.
Requirements for diagnosis of malaria at different levels of the laboratory network in Africa.
Long, Earl G
2009-06-01
The rapid increase of resistance to cheap, reliable antimalarials, the increasing cost of effective drugs, and the low specificity of clinical diagnosis has increased the need for more reliable diagnostic methods for malaria. The most commonly used and most reliable remains microscopic examination of stained blood smears, but this technique requires skilled personnel, precision instruments, and ideally a source of electricity. Microscopy has the advantage of enabling the examiner to identify the species, stage, and density of an infection. An alternative to microscopy is the rapid diagnostic test (RDT), which uses a labeled monoclonal antibody to detect circulating parasitic antigens. This test is most commonly used to detect Plasmodium falciparum infections and is available in a plastic cassette format. Both microscopy and RDTs should be available at all levels of laboratory service in endemic areas, but in peripheral laboratories with minimally trained staff, the RDT may be a more practical diagnostic method.
Benefits and challenges of molecular diagnostics for childhood tuberculosis.
Gutierrez, Cristina
2016-12-01
Expanding tuberculosis (TB)-diagnostic services, including access to rapid tests, is a World Health Organization (WHO) strategy to accelerate progress toward ending TB. Faster and more sensitive molecular tests capable of diagnosing TB and drug-resistant TB have the technical capacity to address limitations associated with smears and cultures by increasing accuracy and shortening turnaround times as compared with those of these conventional laboratory methods. Nucleic acid amplification assays used to detect and analyze Mycobacterium tuberculosis (MTB)-complex nucleic acids can be used directly on specimens from patients suspected of having TB. Recently, several commercial molecular tests were developed to detect MTB and determine the drug resistance (DR) based on detection of specific genetic mutations conferring resistance. The first to be endorsed by the WHO was molecular line-probe assay technology. This test uses polymerase chain reaction (PCR) and reverse-hybridization methods to rapidly identify MTB and DR-related mutations simultaneously. More recently, the WHO endorsed Xpert MTB/RIF, Cepheid Inc, CA, USA, a fully automated assay used for TB diagnosis that relies upon PCR techniques for detection of TB and rifampicin resistance-related mutations. Other promising molecular TB assays for simplifying PCR-based testing protocols and increasing their accuracy are under development and evaluation. Although we lack a practical gold standard for the diagnosis of childhood TB, its bacteriological confirmation is always recommended to be sought whenever possible prior to a diagnostic decision being made. Conventional diagnostic laboratory TB tests are less efficient for children as compared with adults, because sufficient sputum samples are more difficult to collect from infants and young children, and their disease is often paucibacillary, resulting in smear-negative disease. These inherent challenges associated with childhood TB are due to immunological- and pathophysiological-response differences relative to those observed in adults. Several recent meta-analyses showed low sensitivity estimates of PCR-based TB assays for paucibacillary forms of TB (extrapulmonary TB and smear-negative pulmonary disease), which represent the vast majority of childhood TB cases. Despite the lack of evidence regarding use of the rapid molecular assays to identify TB and detect DR in children, and due to the clinical nature of childhood TB, TB-expert groups recommend including rapid methods for TB identification and DR detection in diagnostic algorithms for children suspected of both smear-positive and -negative pulmonary or extrapulmonary TB, both with or without human immunodeficiency virus (HIV)-coinfection, when combined with standard methods (including clinical, microbiological, and radiological assessment) for diagnosing active TB and conventional DR. Since 2011, the WHO has specifically recommended use of the Xpert MTB/RIF test as an initial diagnostic tool for children with suspected HIV-associated TB or multidrug-resistant TB based on successful treatment data related to adults. Implementation of the rapid molecular assays for rapid detection of TB and DR should occur in laboratories with proven capability to run molecular tests and where quality control systems are implemented. Molecular approaches should be more largely tested in children, given their status as the group in whom the diagnostic dilemma is most pronounced. These tests should also be included in specific childhood TB diagnostic algorithms adapted to the local/national context in combination with other strategies for improving diagnostics, including more effective specimen collection. Copyright © 2016.
Nolte, Thomas; Brander-Weber, Patricia; Dangler, Charles; Deschl, Ulrich; Elwell, Michael R; Greaves, Peter; Hailey, Richard; Leach, Michael W; Pandiri, Arun R; Rogers, Arlin; Shackelford, Cynthia C; Spencer, Andrew; Tanaka, Takuji; Ward, Jerrold M
2016-01-01
The INHAND (International Harmonization of Nomenclature and Diagnostic Criteria for Lesions in Rats and Mice) project is a joint initiative of the Societies of Toxicologic Pathology from Europe (ESTP), Great Britain (BSTP), Japan (JSTP), and North America (STP) to develop an internationally accepted nomenclature and diagnostic criteria for nonproliferative and proliferative lesions in laboratory animals. The purpose of this publication is to provide a standardized nomenclature and diagnostic criteria for classifying lesions in the digestive system including the salivary glands and the exocrine pancreas of laboratory rats and mice. Most lesions are illustrated by color photomicrographs. The standardized nomenclature, the diagnostic criteria, and the photomicrographs are also available electronically on the Internet (http://www.goreni.org/). Sources of material included histopathology databases from government, academia, and industrial laboratories throughout the world. Content includes spontaneous and age related lesions as well as lesions induced by exposure to test items. Relevant infectious and parasitic lesions are included as well. A widely accepted and utilized international harmonization of nomenclature and diagnostic criteria for the digestive system will decrease misunderstandings among regulatory and scientific research organizations in different countries and provide a common language to increase and enrich international exchanges of information among toxicologists and pathologists.
Nolte, Thomas; Brander-Weber, Patricia; Dangler, Charles; Deschl, Ulrich; Elwell, Michael R.; Greaves, Peter; Hailey, Richard; Leach, Michael W.; Pandiri, Arun R.; Rogers, Arlin; Shackelford, Cynthia C.; Spencer, Andrew; Tanaka, Takuji; Ward, Jerrold M.
2016-01-01
The INHAND (International Harmonization of Nomenclature and Diagnostic Criteria for Lesions in Rats and Mice) project is a joint initiative of the Societies of Toxicologic Pathology from Europe (ESTP), Great Britain (BSTP), Japan (JSTP), and North America (STP) to develop an internationally accepted nomenclature and diagnostic criteria for nonproliferative and proliferative lesions in laboratory animals. The purpose of this publication is to provide a standardized nomenclature and diagnostic criteria for classifying lesions in the digestive system including the salivary glands and the exocrine pancreas of laboratory rats and mice. Most lesions are illustrated by color photomicrographs. The standardized nomenclature, the diagnostic criteria, and the photomicrographs are also available electronically on the Internet (http://www.goreni.org/). Sources of material included histopathology databases from government, academia, and industrial laboratories throughout the world. Content includes spontaneous and age related lesions as well as lesions induced by exposure to test items. Relevant infectious and parasitic lesions are included as well. A widely accepted and utilized international harmonization of nomenclature and diagnostic criteria for the digestive system will decrease misunderstandings among regulatory and scientific research organizations in different countries and provide a common language to increase and enrich international exchanges of information among toxicologists and pathologists. PMID:26973378
Model Based Inference for Wire Chafe Diagnostics
NASA Technical Reports Server (NTRS)
Schuet, Stefan R.; Wheeler, Kevin R.; Timucin, Dogan A.; Wysocki, Philip F.; Kowalski, Marc Edward
2009-01-01
Presentation for Aging Aircraft conference covering chafing fault diagnostics using Time Domain Reflectometry. Laboratory setup and experimental methods are presented, along with initial results that summarize fault modeling and detection capabilities.
Magnetic Levitation Coupled with Portable Imaging and Analysis for Disease Diagnostics.
Knowlton, Stephanie M; Yenilmez, Bekir; Amin, Reza; Tasoglu, Savas
2017-02-19
Currently, many clinical diagnostic procedures are complex, costly, inefficient, and inaccessible to a large population in the world. The requirements for specialized equipment and trained personnel require that many diagnostic tests be performed at remote, centralized clinical laboratories. Magnetic levitation is a simple yet powerful technique and can be applied to levitate cells, which are suspended in a paramagnetic solution and placed in a magnetic field, at a position determined by equilibrium between a magnetic force and a buoyancy force. Here, we present a versatile platform technology designed for point-of-care diagnostics which uses magnetic levitation coupled to microscopic imaging and automated analysis to determine the density distribution of a patient's cells as a useful diagnostic indicator. We present two platforms operating on this principle: (i) a smartphone-compatible version of the technology, where the built-in smartphone camera is used to image cells in the magnetic field and a smartphone application processes the images and to measures the density distribution of the cells and (ii) a self-contained version where a camera board is used to capture images and an embedded processing unit with attached thin-film-transistor (TFT) screen measures and displays the results. Demonstrated applications include: (i) measuring the altered distribution of a cell population with a disease phenotype compared to a healthy phenotype, which is applied to sickle cell disease diagnosis, and (ii) separation of different cell types based on their characteristic densities, which is applied to separate white blood cells from red blood cells for white blood cell cytometry. These applications, as well as future extensions of the essential density-based measurements enabled by this portable, user-friendly platform technology, will significantly enhance disease diagnostic capabilities at the point of care.
Aziz, Nazneen; Zhao, Qin; Bry, Lynn; Driscoll, Denise K; Funke, Birgit; Gibson, Jane S; Grody, Wayne W; Hegde, Madhuri R; Hoeltge, Gerald A; Leonard, Debra G B; Merker, Jason D; Nagarajan, Rakesh; Palicki, Linda A; Robetorye, Ryan S; Schrijver, Iris; Weck, Karen E; Voelkerding, Karl V
2015-04-01
The higher throughput and lower per-base cost of next-generation sequencing (NGS) as compared to Sanger sequencing has led to its rapid adoption in clinical testing. The number of laboratories offering NGS-based tests has also grown considerably in the past few years, despite the fact that specific Clinical Laboratory Improvement Amendments of 1988/College of American Pathologists (CAP) laboratory standards had not yet been developed to regulate this technology. To develop a checklist for clinical testing using NGS technology that sets standards for the analytic wet bench process and for bioinformatics or "dry bench" analyses. As NGS-based clinical tests are new to diagnostic testing and are of much greater complexity than traditional Sanger sequencing-based tests, there is an urgent need to develop new regulatory standards for laboratories offering these tests. To develop the necessary regulatory framework for NGS and to facilitate appropriate adoption of this technology for clinical testing, CAP formed a committee in 2011, the NGS Work Group, to deliberate upon the contents to be included in the checklist. Results . -A total of 18 laboratory accreditation checklist requirements for the analytic wet bench process and bioinformatics analysis processes have been included within CAP's molecular pathology checklist (MOL). This report describes the important issues considered by the CAP committee during the development of the new checklist requirements, which address documentation, validation, quality assurance, confirmatory testing, exception logs, monitoring of upgrades, variant interpretation and reporting, incidental findings, data storage, version traceability, and data transfer confidentiality.
Laboratory simulation of space plasma phenomena*
NASA Astrophysics Data System (ADS)
Amatucci, B.; Tejero, E. M.; Ganguli, G.; Blackwell, D.; Enloe, C. L.; Gillman, E.; Walker, D.; Gatling, G.
2017-12-01
Laboratory devices, such as the Naval Research Laboratory's Space Physics Simulation Chamber, are large-scale experiments dedicated to the creation of large-volume plasmas with parameters realistically scaled to those found in various regions of the near-Earth space plasma environment. Such devices make valuable contributions to the understanding of space plasmas by investigating phenomena under carefully controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. By working in collaboration with in situ experimentalists to create realistic conditions scaled to those found during the observations of interest, the microphysics responsible for the observed events can be investigated in detail not possible in space. To date, numerous investigations of phenomena such as plasma waves, wave-particle interactions, and particle energization have been successfully performed in the laboratory. In addition to investigations such as plasma wave and instability studies, the laboratory devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this presentation, we will describe several examples of the laboratory investigation of space plasma waves and instabilities and diagnostic development. *This work supported by the NRL Base Program.
Williamson, Julie A; Tornquist, Susan J
2014-01-01
There is a huge unmet need for veterinary diagnostic laboratory services in developing nations such as Liberia. One way of bridging the service gap is for visiting experts to provide veterinary laboratory training to technicians in a central location in a short-course format. An intensive 1-week training workshop was organized for 18 student and faculty participants from the College of Agriculture and Integrated Development Studies (CAIDS) at Cuttington University in rural central Liberia. The training was designed and delivered by the non-governmental organization Veterinarians Without Borders US and funded through a Farmer-to-Farmer grant provided by the United States Agency for International Development. Although at the start of training none of the students had any veterinary laboratory experience, by the end of the course over 80% of the students were able to discuss appropriate care and use of a microscope and name at least three important components of laboratory record keeping; over 60% were able to describe how to make and stain a blood smear and how to perform a passive fecal flotation; and over 30% were able to describe what a packed cell volume is and how it is measured and name at least three criteria for classifying bacteria. The intensive training workshop greatly improved the knowledge of trainees about veterinary diagnostic laboratory techniques. The training provided initial skills to students and faculty who are awaiting the arrival of additional grant-funded laboratory equipment to continue their training.
Langlois, Michel R; Wallemacq, Pierre
2009-01-01
To face the economic pressures arising from the current socio-economic conjuncture, hospital laboratories are endangered by an increasing trend towards the outsourcing of clinical laboratory tests to external (mega-) laboratories. This should allow hospitals to meet their economic requirements, but with an increased risk of loss of medical quality and, mid- to long-term, loss of cost effectiveness of healthcare at the national level. To anticipate current developments (economical and technological) that inevitably will affect the future of laboratory medicine, hospital laboratories should be proactive and enhance efficiency, reduce costs by consolidation, integrate into regional networks, and form alliances or partnerships. To create additional value, the core competency of laboratory professionals must be refocused to provide medical knowledge services (consultative support to clinicians) related to in vitro diagnostic testing. To integrate cost-efficiency with medical quality, implementation of a matricial organization - operational vs. biomedical level - could be an interesting approach. This integrated structure should create total quality of laboratory testing, managing the entire medical diagnostic cycle from the pre-preanalytical to post-postanalytical phase.
Gilbert, G L
2015-08-01
If routine laboratory safety precautions are followed, the risk of laboratory-acquired infection from handling specimens from patients with Ebolavirus disease (EVD) is very low, especially in the early 'dry' stage of disease. In Australia, border screening to identify travellers returning from EVD-affected west African countries during the 2014-2015 outbreak has made it unlikely that specimens from patients with unrecognised EVD would be sent to a routine diagnostic laboratory. Australian public health and diagnostic laboratories associated with hospitals designated for the care of patients with EVD have developed stringent safety precautions for EVD diagnostic and other tests likely to be required for supportive care of the sickest (and most infectious) patients with EVD, including as wide a range of point-of-care tests as possible. However, it is important that the stringent requirements for packaging, transport and testing of specimens that might contain Ebolavirus--which is a tier 1 security sensitive biology agent--do not delay the diagnosis and appropriate management of other potentially serious but treatable infectious diseases, which are far more likely causes of a febrile illness in people returning from west Africa. If necessary, urgent haematology, biochemistry and microbiological tests can be performed safely, whilst awaiting the results of EVD tests, in a PC-2 laboratory with appropriate precautions including: use of recommended personal protective equipment (PPE) for laboratory staff; handling any unsealed specimens in a class 1 or II biosafety cabinet; using only centrifuges with sealed rotors; and safe disposal or decontamination of all used equipment and laboratory waste.
Laboratory Diagnosis of Congenital Toxoplasmosis.
Pomares, Christelle; Montoya, Jose G
2016-10-01
Recent studies have demonstrated that screening and treatment for toxoplasmosis during gestation result in a decrease of vertical transmission and clinical sequelae. Early treatment was associated with improved outcomes. Thus, laboratory methods should aim for early identification of infants with congenital toxoplasmosis (CT). Diagnostic approaches should include, at least, detection of Toxoplasma IgG, IgM, and IgA and a comprehensive review of maternal history, including the gestational age at which the mother was infected and treatment. Here, we review laboratory methods for the diagnosis of CT, with emphasis on serological tools. A diagnostic algorithm that takes into account maternal history is presented. Copyright © 2016 Pomares and Montoya.
Mussap, Michele
2014-01-01
The rapid escalation in health care costs has led to the idea to deliver better care at lower costs, reshaping the responsibilities of the health care system to achieve the goal of creating value for the patient. The pressure for fiscal containment and the progressive reduction in available health care resources originated very short term strategies consisting of abrupt reductions in expenditure, specifically in the provision of clinical pathology laboratory medicine services. However, the impact of laboratory test results on diagnostic and therapeutic interventions has increased enormously in the past decade, due to advances in personalized medicine and to the strictly correlated requirement to use new biomarkers with increasing sensitivity and specificity in clinical practice. In order to create savings by delivering better care there is the need to invest financial resources in purchasing high technology and new sophisticated tests and to promote the expertise of clinical pathologists and laboratory medicine professionals. This approach to creating value in patient health care is more productive and sustainable ethically, morally and economically as a long-term strategy. It can be successfully achieved by applying defined rules that make public-private cooperation clearer, skipping incompatible solutions such as transforming clinical laboratories to 'industrially productive premises', outsourcing laboratory medicine services and using central acquisition of diagnostic systems. © 2013.
Bottom-up or top-down: unit cost estimation of tuberculosis diagnostic tests in India.
Rupert, S; Vassall, A; Raizada, N; Khaparde, S D; Boehme, C; Salhotra, V S; Sachdeva, K S; Nair, S A; Hoog, A H Van't
2017-04-01
Of 18 sites that participated in an implementation study of the Xpert® MTB/RIF assay in India, we selected five microscopy centres and two reference laboratories. To obtain unit costs of diagnostic tests for tuberculosis (TB) and drug-resistant TB. Laboratories were purposely selected to capture regional variations and different laboratory types. Both bottom-up and the top-down methods were used to estimate unit costs. At the microscopy centres, mean bottom-up unit costs were respectively US$0.83 (range US$0.60-US$1.10) and US$12.29 (US$11.61-US$12.89) for sputum smear microscopy and Xpert. At the reference laboratories, mean unit costs were US$1.69 for the decontamination procedure, US$9.83 for a solid culture, US$11.06 for a liquid culture, US$29.88 for a drug susceptibility test, and US$18.18 for a line-probe assay. Top-down mean unit cost estimates were higher for all tests, and for sputum smear microscopy and Xpert these increased to respectively US$1.51 and US$13.58. The difference between bottom-up and top-down estimates was greatest for tests performed at the reference laboratories. These unit costs for TB diagnostics can be used to estimate resource requirements and cost-effectiveness in India, taking into account geographical location, laboratory type and capacity utilisation.
X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... Chernecky CC, Berger BJ. Radiography of skull, chest, and cervical spine - diagnostic. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. ...
Delfiner, Matthew S; Martinez, Luis R; Pavia, Charles S
2016-01-01
Laboratory diagnostic tests have an essential role in patient care, and the increasing number of medical and health professions schools focusing on teaching laboratory medicine to pre-clinical students reflects this importance. However, data validating the pedagogical methods that best influence students' comprehension and interpretation of diagnostic tests have not been well described. The Gram stain is a simple yet significant and frequently used diagnostic test in the clinical setting that helps classify bacteria into two major groups, Gram positive and negative, based on their cell wall structure. We used this technique to assess which educational strategies may improve students' learning and competency in medical diagnostic techniques. Hence, in this randomized controlled study, we compared the effectiveness of several educational strategies (e.g. workshop, discussion, or lecture) in first year medical students' competency in comprehension and interpretation of the Gram stain procedure. We demonstrated that a hands-on practical workshop significantly enhances students' competency in memorization and overall comprehension of the technique. Interestingly, most students irrespective of their cohort showed difficulty in answering Gram stain-related analytical questions, suggesting that more emphasis should be allocated by the instructors to clearly explain the interpretation of the diagnostic test results to students in medical and health professional schools. This proof of principle study highlights the need of practical experiences on laboratory medical techniques during pre-clinical training to facilitate future medical doctors' and healthcare professionals' basic understanding and competency in diagnostic testing for better patient care.
20 CFR 220.113 - Symptoms, signs, and laboratory findings.
Code of Federal Regulations, 2011 CFR
2011-04-01
... are medically demonstrable phenomena which indicate specific abnormalities of behavior, affect... psychological phenomena which can be shown by the use of medically acceptable laboratory diagnostic techniques...
Diagnostics for a waste processing plasma arc furnace (invited) (abstract)a)
NASA Astrophysics Data System (ADS)
Woskov, P. P.
1995-01-01
Maintaining the quality of our environment has become an important goal of society. As part of this goal new technologies are being sought to clean up hazardous waste sites and to treat ongoing waste streams. A 1 MW pilot scale dc graphite electrode plasma arc furnace (Mark II) has been constructed at MIT under a joint program among Pacific Northwest Laboratory (PNL), MIT, and Electro-Pyrolysis, Inc. (EPI)c) for the remediation of buried wastes in the DOE complex. A key part of this program is the development of new and improved diagnostics to study, monitor, and control the entire waste remediation process for the optimization of this technology and to safeguard the environment. Continuous, real time diagnostics are needed for a variety of the waste process parameters. These parameters include internal furnace temperatures, slag fill levels, trace metals content in the off-gas stream, off-gas molecular content, feed and slag characterization, and off-gas particulate size, density, and velocity distributions. Diagnostics are currently being tested at MIT for the first three parameters. An active millimeter-wave radiometer with a novel, rotatable graphite waveguide/mirror antenna system has been implemented on Mark II for the measurement of surface emission and emissivity which can be used to determine internal furnace temperatures and fill levels. A microwave torch plasma is being evaluated for use as a excitation source in the furnace off-gas stream for continuous atomic emission spectroscopy of trace metals. These diagnostics should find applicability not only to waste remediation, but also to other high temperature processes such as incinerators, power plants, and steel plants.
Diagnosis of Ebola Virus Disease: Past, Present, and Future
Brooks, Tim J. G.
2016-01-01
SUMMARY Laboratory diagnosis of Ebola virus disease plays a critical role in outbreak response efforts; however, establishing safe and expeditious testing strategies for this high-biosafety-level pathogen in resource-poor environments remains extremely challenging. Since the discovery of Ebola virus in 1976 via traditional viral culture techniques and electron microscopy, diagnostic methodologies have trended toward faster, more accurate molecular assays. Importantly, technological advances have been paired with increasing efforts to support decentralized diagnostic testing capacity that can be deployed at or near the point of patient care. The unprecedented scope of the 2014-2015 West Africa Ebola epidemic spurred tremendous innovation in this arena, and a variety of new diagnostic platforms that have the potential both to immediately improve ongoing surveillance efforts in West Africa and to transform future outbreak responses have reached the field. In this review, we describe the evolution of Ebola virus disease diagnostic testing and efforts to deploy field diagnostic laboratories in prior outbreaks. We then explore the diagnostic challenges pervading the 2014-2015 epidemic and provide a comprehensive examination of novel diagnostic tests that are likely to address some of these challenges moving forward. PMID:27413095
Recent Progress and Future Plans for Fusion Plasma Synthetic Diagnostics Platform
NASA Astrophysics Data System (ADS)
Shi, Lei; Kramer, Gerrit; Tang, William; Tobias, Benjamin; Valeo, Ernest; Churchill, Randy; Hausammann, Loic
2015-11-01
The Fusion Plasma Synthetic Diagnostics Platform (FPSDP) is a Python package developed at the Princeton Plasma Physics Laboratory. It is dedicated to providing an integrated programmable environment for applying a modern ensemble of synthetic diagnostics to the experimental validation of fusion plasma simulation codes. The FPSDP will allow physicists to directly compare key laboratory measurements to simulation results. This enables deeper understanding of experimental data, more realistic validation of simulation codes, quantitative assessment of existing diagnostics, and new capabilities for the design and optimization of future diagnostics. The Fusion Plasma Synthetic Diagnostics Platform now has data interfaces for the GTS and XGC-1 global particle-in-cell simulation codes with synthetic diagnostic modules including: (i) 2D and 3D Reflectometry; (ii) Beam Emission Spectroscopy; and (iii) 1D Electron Cyclotron Emission. Results will be reported on the delivery of interfaces for the global electromagnetic PIC code GTC, the extended MHD M3D-C1 code, and the electromagnetic hybrid NOVAK eigenmode code. Progress toward development of a more comprehensive 2D Electron Cyclotron Emission module will also be discussed. This work is supported by DOE contract #DEAC02-09CH11466.
Stevens, Richard C.; Soelberg, Scott D.; Near, Steve; Furlong, Clement E.
2011-01-01
Saliva provides a useful and non-invasive alternative to blood for many biomedical diagnostic assays. The level of the hormone cortisol in blood and saliva is related to the level of stress. We present here the development of a portable surface plasmon resonance (SPR) biosensor system for detection of cortisol in saliva. Cortisol-specific monoclonal antibodies were used to develop a competition assay with a 6-channel portable SPR biosensor designed in our laboratory. The detection limit of cortisol in laboratory buffers was 0.36 ng/ml (1.0 nM). An in-line filter based on diffusion through a hollow fiber hydrophilic membrane served to separate small molecules from the complex macromolecular matrix of saliva prior to introduction to the sensor surface. The filtering flow cell provided in-line separation of small molecules from salivary mucins and other large molecules with only a 29% reduction of signal compared with direct flow of the same concentration of analyte over the sensor surface. A standard curve for detection of cortisol in saliva was generated with a detection limit of 1.0 ng/ml (3.6 nM), sufficiently sensitive for clinical use. The system will also be useful for a wide range of applications where small molecular weight analytes are found in complex matrices. PMID:18656950
Application of imaging spectrometer data to the Kings-Kaweah ophiolite melange
NASA Technical Reports Server (NTRS)
Mustard, John F.; Pieters, Carle M.
1988-01-01
The Kings-Kaweah ophiolite melange in east-central California is thought to be an obducted oceanic fracture zone and provides the rare opportunity to examine in detail the complex nature of this type of terrain. It is anticipated that the distribution and abundance of components in the melange can be used to determine the relative importance of geologic processes responsible for the formation of fracture zone crust. Laboratory reflectance spectra of field samples indicate that the melange components have distinct, diagnostic absorptions at visible to near-infrared wavelengths. The spatial and spectral resolution of AVIRIS is ideally suited for addressing important scientific questions concerning the Kings-Kaweah ophiolite melange and fracture zones in general.
Britton, Sumudu; Cheng, Qin; McCarthy, James S
2016-02-16
As malaria transmission continues to decrease, an increasing number of countries will enter pre-elimination and elimination. To interrupt transmission, changes in control strategies are likely to require more accurate identification of all carriers of Plasmodium parasites, both symptomatic and asymptomatic, using diagnostic tools that are highly sensitive, high throughput and with fast turnaround times preferably performed in local health service settings. Currently available immunochromatographic lateral flow rapid diagnostic tests and field microscopy are unlikely to consistently detect infections at parasite densities less than 100 parasites/µL making them insufficiently sensitive for detecting all carriers. Molecular diagnostic platforms, such as PCR and LAMP, are currently available in reference laboratories, but at a cost both financially and in turnaround time. This review describes the recent progress in developing molecular diagnostic tools in terms of their capacity for high throughput and potential for performance in non-reference laboratories for malaria elimination.
2016-01-01
It is important to consider the role of diagnostics and the critical need for quality diagnostics services in resource-limited settings. Accurate diagnostic tests play a key role in patient management and the prevention and control of most infectious diseases. As countries plan for implementation of HIV early infant diagnosis and viral load point-of-care testing, the London School of Hygiene & Tropical Medicine has worked with countries and partners with an interest in external quality assurance to support quality point-of-care testing on the continent. Through a series of collaborative consultations and workshops, the London School of Hygiene & Tropical Medicine has gathered lessons learned, tools, and resources and developed quality assurance models that will support point-of-care testing. The London School of Hygiene & Tropical Medicine is committed to the continued advancement of laboratory diagnostics in Africa and quality laboratory services and point-of-care testing. PMID:28879132
Information engineering for molecular diagnostics.
Sorace, J. M.; Ritondo, M.; Canfield, K.
1994-01-01
Clinical laboratories are beginning to apply the recent advances in molecular biology to the testing of patient samples. The emerging field of Molecular Diagnostics will require a new Molecular Diagnostics Laboratory Information System which handles the data types, samples and test methods found in this field. The system must be very flexible in regards to supporting ad-hoc queries. The requirements which are shaping the developments in this field are reviewed and a data model developed. Several queries which demonstrate the data models ability to support the information needs of this area have been developed and run. These results demonstrate the ability of the purposed data model to meet the current and projected needs of this rapidly expanding field. PMID:7949937
Food and Drug Administration Regulation of in Vitro Diagnostic Devices
Mansfield, Elizabeth; O’Leary, Timothy J.; Gutman, Steven I.
2005-01-01
The Food and Drug Administration regulates the sale and distribution of laboratory devices under a statutory and regulatory framework that is unfamiliar to most clinical laboratory scientists. In this article we briefly describe the criteria that are used to classify and review in vitro diagnostic devices. We discuss the similarities and differences between devices that are not subject to premarket review, and those that are required to undergo either a premarket application or premarket notification [510(k)] pathway. We then discuss the methods that the Food and Drug Administration uses to assess the performance of in vitro diagnostic devices in the marketplace as a component of the total life cycle approach to medical device regulation. PMID:15681468
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-04
...] Notice of Request for Approval of an Information Collection; National Veterinary Services Laboratories... collection associated with the National Veterinary Services Laboratories animal health diagnostic system...: For information on request forms associated with the National Veterinary Services Laboratories animal...
NASA Astrophysics Data System (ADS)
Rogatkin, Dmitrii A.; Tchernyi, Vladimir V.
2003-07-01
The optical noninvasive diagnostic systems are now widely applied and investigated in different areas of medicine. One of the such techniques is the noninvasive spectrophotometry, the complex diagnostic technique consisting on elastic scattering spectroscopy, absorption spectroscopy, fluorescent diagnostics, photoplethismography, etc. Today a lot of real optical diagnostic systems indicate the technical parameters and physical data only as a result of the diagnostic procedure. But, it is clear that for the medical staff the more convenient medical information is needed. This presentation lights the general way for development a diagnostic system"s software, which can produce the full processing of the diagnostic data from a physical to a medical level. It is shown, that this process is a multilevel (3-level) procedure and the main diagnostic result for noninvasive spectrophotometry methods, the biochemical and morphological composition of the tested tissues, arises in it on a second level of calculations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allendorf, Mark D.; Stavila, Vitalie; Klebanoff, Leonard E.
2017-07-01
The Sandia HyMARC team continued its development of new synthetic, modeling, and diagnostic tools that are providing new insights into all major classes of storage materials, ranging from relatively simple systems such as PdHx and MgH2, to exceptionally complex ones, such as the metal borohydrides, as well as materials thought to be very well-understood, such as Ti-doped NaAlH4. This unprecedented suite of capabilities, capable of probing all relevant length scales within storage materials, is already having a significant impact, as they are now being used by both Seedling projects and collaborators at other laboratories within HyMARC. We expect this impactmore » to grow as new Seedling projects begin and through collaborations with other scientists outside HyMARC. In the coming year, Sandia efforts will focus on the highest impact problems, in coordination with the other HyMARC National Laboratory partners, to provide the foundational science necessary to accelerate the discovery of new hydrogen storage materials.« less
NASA Astrophysics Data System (ADS)
Bader, D. C.
2015-12-01
The Accelerated Climate Modeling for Energy (ACME) Project is concluding its first year. Supported by the Office of Science in the U.S. Department of Energy (DOE), its vision is to be "an ongoing, state-of-the-science Earth system modeling, modeling simulation and prediction project that optimizes the use of DOE laboratory resources to meet the science needs of the nation and the mission needs of DOE." Included in the "laboratory resources," is a large investment in computational, network and information technologies that will be utilized to both build better and more accurate climate models and broadly disseminate the data they generate. Current model diagnostic analysis and data dissemination technologies will not scale to the size of the simulations and the complexity of the models envisioned by ACME and other top tier international modeling centers. In this talk, the ACME Workflow component plans to meet these future needs will be described and early implementation examples will be highlighted.
Missed diagnostic opportunities within South Africa's early infant diagnosis program, 2010-2015.
Haeri Mazanderani, Ahmad; Moyo, Faith; Sherman, Gayle G
2017-01-01
Samples submitted for HIV PCR testing that fail to yield a positive or negative result represent missed diagnostic opportunities. We describe HIV PCR test rejections and indeterminate results, and the associated delay in diagnosis, within South Africa's early infant diagnosis (EID) program from 2010 to 2015. HIV PCR test data from January 2010 to December 2015 were extracted from the National Health Laboratory Service Corporate Data Warehouse, a central data repository of all registered test-sets within the public health sector in South Africa, by laboratory number, result, date, facility, and testing laboratory. Samples that failed to yield either a positive or negative result were categorized according to the rejection code on the laboratory information system, and descriptive analysis performed using Microsoft Excel. Delay in diagnosis was calculated for patients who had a missed diagnostic opportunity registered between January 2013 and December 2015 by means of a patient linking-algorithm employing demographic details. Between 2010 and 2015, 2 178 582 samples were registered for HIV PCR testing of which 6.2% (n = 134 339) failed to yield either a positive or negative result, decreasing proportionally from 7.0% (n = 20 556) in 2010 to 4.4% (n = 21 388) in 2015 (p<0.001). Amongst 76 972 coded missed diagnostic opportunities, 49 585 (64.4%) were a result of pre-analytical error and 27 387 (35.6%) analytical error. Amongst 49 694 patients searched for follow-up results, 16 895 (34.0%) had at least one subsequent HIV PCR test registered after a median of 29 days (IQR: 13-57), of which 8.4% tested positive compared with 3.6% of all samples submitted for the same period. Routine laboratory data provides the opportunity for near real-time surveillance and quality improvement within the EID program. Delay in diagnosis and wastage of resources associated with missed diagnostic opportunities must be addressed and infants actively followed-up as South Africa works towards elimination of mother-to-child transmission.
Laboratory automation: trajectory, technology, and tactics.
Markin, R S; Whalen, S A
2000-05-01
Laboratory automation is in its infancy, following a path parallel to the development of laboratory information systems in the late 1970s and early 1980s. Changes on the horizon in healthcare and clinical laboratory service that affect the delivery of laboratory results include the increasing age of the population in North America, the implementation of the Balanced Budget Act (1997), and the creation of disease management companies. Major technology drivers include outcomes optimization and phenotypically targeted drugs. Constant cost pressures in the clinical laboratory have forced diagnostic manufacturers into less than optimal profitability states. Laboratory automation can be a tool for the improvement of laboratory services and may decrease costs. The key to improvement of laboratory services is implementation of the correct automation technology. The design of this technology should be driven by required functionality. Automation design issues should be centered on the understanding of the laboratory and its relationship to healthcare delivery and the business and operational processes in the clinical laboratory. Automation design philosophy has evolved from a hardware-based approach to a software-based approach. Process control software to support repeat testing, reflex testing, and transportation management, and overall computer-integrated manufacturing approaches to laboratory automation implementation are rapidly expanding areas. It is clear that hardware and software are functionally interdependent and that the interface between the laboratory automation system and the laboratory information system is a key component. The cost-effectiveness of automation solutions suggested by vendors, however, has been difficult to evaluate because the number of automation installations are few and the precision with which operational data have been collected to determine payback is suboptimal. The trend in automation has moved from total laboratory automation to a modular approach, from a hardware-driven system to process control, from a one-of-a-kind novelty toward a standardized product, and from an in vitro diagnostics novelty to a marketing tool. Multiple vendors are present in the marketplace, many of whom are in vitro diagnostics manufacturers providing an automation solution coupled with their instruments, whereas others are focused automation companies. Automation technology continues to advance, acceptance continues to climb, and payback and cost justification methods are developing.
Taremwa, Ivan Mugisha; Ampaire, Lucas; Iramiot, Jacob; Muhwezi, Obed; Matte, Aloysius; Itabangi, Herbert; Mbabazi, Hope; Atwebembeire, Jeninah; Kamwine, Monicah; Katawera, Victoria; Mbalibulha, Yona; Orikiriza, Patrick; Boum, Yap
2017-01-01
While the laboratory represents more than 70% of clinical diagnosis and patient management, access to reliable and quality laboratory diagnostics in sub-Saharan Africa remains a challenge. To gain knowledge and suggest evidence based interventions towards laboratory improvement in Southwestern Uganda, we assessed the baseline laboratory quality standards in three medical and research laboratories in Southwestern Uganda. We conducted a cross sectional survey from October, 2013 to April, 2014. Selected laboratories, including one private research, one private for profit and one public laboratory, were assessed using the WHO AFRO_SLIPTA checklist and baseline scores were determined. The three laboratories assessed met basic facility requirements, had trained personnel, and safety measures in place. Sample reception was properly designed and executed with a well designated chain of custody. All laboratories had sufficient equipment for the nature of work they were involved in. However, we found that standard operating procedures were incomplete in all three laboratories, lack of quality audit schemes by two laboratories and only one laboratory enrolled into external quality assurance schemes. The SLIPTA scores were one star for the research laboratory and no star for both the public and private-for-profit laboratories. While most of the laboratory systems were in place, the low scores obtained by the assessed laboratories reflect the need for improvement to reach standards of quality assured diagnostics in the region. Therefore, routine mentorship and regional supportive supervision are necessary to increase the quality of laboratory services.
Cepický, P; Malina, J; Líbalová, Z; Kuzelová, M
2005-05-01
The evaluation of combined and miscellaneous vulvovaginal infections incidence and their treatment with combined vaginal products containing nifuratel and nystatin. Prospective study. Gynecologic outpatient department LEVRET, Prague; Laboratories of Microbiology AescuLab, Prague. 70 consecutive patients were examined with complaint of vaginal fluor and/or pruritus. We established macroscopic features of fluor, pH, amine test and mounts stained with Giemsa and Gram. We qualified the cases with more diagnostic criteria (mycosis, lactobacillosis, anaerobic vaginosis, aerobic vaginitis) as combined infection, those with no diagnostic criteria as miscellaneous. We treated all patients with vaginal tablets nystatin + nifuratel (Macmiror complex). We prescribed clotrimazol cream, if pruritus was present. We evaluated withdrawals of symptoms and relapses during 3 months after treatment. Combined infection was found in 21 patients from 70 (30%). The most frequent combination was that of mycosis and aerobic vaginitis (13/70, 18.6%) or mycosis and anaerobic vaginosis (4/70, 5.7%); 11 patients fulfilled criteria of no diagnosis. We concluded them as "miscelaneous". The treatment was successful in all cases, 10 women relapsed in 3 months. Combined vaginal infection findings are present very often (30%), likewise miscellaneous ones (15%) occur. The treatment of these women in successful with vaginal tablets with nystatin + nifuratel.
Hirschfeldova, Katerina; Florianova, Martina; Kebrdlova, Vera; Urbanova, Marketa; Stekrova, Jitka
2017-02-01
Heterozygous aberrations of SHOX gene have been reported to be responsible for Léri-Weill dyschondrosteosis (LWD) and small portion of idiopathic short stature. The study was established to assess effectiveness of using phenotype 'scoring form' in patients indicated for SHOX gene defect analysis. The submitted study is based on a retrospective group of 352 unrelated patients enrolled as a part of the routine diagnostic practice and analyzed for aberrations affecting the SHOX gene. All participants were scanned for deletion/duplication within the main pseudoautosomal region (PAR1) using the multiplex ligation-dependent probe amplification (MLPA) method. The phenotype 'scoring form' is used in our laboratory practice to preselect patients for subsequent mutation analysis of SHOX gene-coding sequences. The overall detection rate was 11.1% but there was a significant increase in frequency of SHOX gene defect positive with increasing achieved score (P<0.0001). The most frequent aberration was a causal deletion within PAR1. In three probands, MLPA analysis indicated a more complex rearrangement. Madelung deformity or co-occurrence of disproportionate short stature, short forearm and muscular hypertrophy had represented the most potent markers to determine the likelihood of SHOX gene defect detection. We conclude that appliance of phenotype 'scoring form' had saved excessive sample analysis and enabled effective routine diagnostic testing.
Upgrade to the control system of the reflectometry diagnostic of ASDEX upgrade
NASA Astrophysics Data System (ADS)
Graça, S.; Santos, J.; Manso, M. E.
2004-10-01
The broadband frequency modulation-continuous wave microwave/millimeter wave reflectometer of ASDEX upgrade tokamak (Institut für Plasma Physik (IPP), Garching, Germany) developed by Centro de Fusão Nuclear (Lisboa, Portugal) with the collaboration of IPP, is a complex system with 13 channels (O and X modes) and two types of operation modes (swept and fixed frequency). The control system that ensures remote operation of the diagnostic incorporates VME and CAMAC bus based acquisition/timing systems. Microprocessor input/output boards are used to control and monitor the microwave circuitry and associated electronic devices. The implementation of the control system is based on an object-oriented client/server model: a centralized server manages the hardware and receives input from remote clients. Communication is handled through transmission control protocol/internet protocol sockets. Here we describe recent upgrades of the control system aiming to: (i) accommodate new channels; (ii) adapt to the heterogeneity of computing platforms and operating systems; and (iii) overcome remote access restrictions. Platform and operating system independence was achieved by redesigning the graphical user interface in JAVA. As secure shell is the standard remote access protocol adopted in major fusion laboratories, secure shell tunneling was implemented to allow remote operation of the diagnostic through the existing firewalls.
Proteomics boosts translational and clinical microbiology.
Del Chierico, F; Petrucca, A; Vernocchi, P; Bracaglia, G; Fiscarelli, E; Bernaschi, P; Muraca, M; Urbani, A; Putignani, L
2014-01-31
The application of proteomics to translational and clinical microbiology is one of the most advanced frontiers in the management and control of infectious diseases and in the understanding of complex microbial systems within human fluids and districts. This new approach aims at providing, by dedicated bioinformatic pipelines, a thorough description of pathogen proteomes and their interactions within the context of human host ecosystems, revolutionizing the vision of infectious diseases in biomedicine and approaching new viewpoints in both diagnostic and clinical management of the patient. Indeed, in the last few years, many laboratories have matured a series of advanced proteomic applications, aiming at providing individual proteome charts of pathogens, with respect to their morph and/or cell life stages, antimicrobial or antimycotic resistance profiling, epidemiological dispersion. Herein, we aim at reviewing the current state-of-the-art on proteomic protocols designed and set-up for translational and diagnostic microbiological purposes, from axenic pathogens' characterization to microbiota ecosystems' full description. The final goal is to describe applications of the most common MALDI-TOF MS platforms to advanced diagnostic issues related to emerging infections, increasing of fastidious bacteria, and generation of patient-tailored phylotypes. This article is part of a Special Issue entitled: Trends in Microbial Proteomics. © 2013. Published by Elsevier B.V. All rights reserved.
Libman, M. D.; Gyorkos, T. W.; Kokoskin, E.; MacLean, J. D.
2008-01-01
Stool microscopy as performed in clinical parasitology laboratories is a complex procedure with subjective interpretation. Quality assurance (QA) programs often emphasize proficiency testing as an assessment tool. We describe a result reproducibility assessment tool, which can form part of a broader QA program, and which is based on the blinded resubmission of selected clinical samples, using concordance between the reports of the initial and resubmitted specimen as an indicator. Specimens preserved in sodium acetate-acetic acid-formalin can be stored for several months for use in such a program. The presence of multiple protozoa in one specimen does not affect concordance. Some dilution of specimens occurs in this process, and this may explain poor concordance when specimens with low protozoal concentrations are resubmitted. Evaluation of this tool in a large parasitology laboratory revealed concordance rates for pathogenic protozoa (Entamoeba histolytica/Entamoeba dispar, Giardia lamblia, and Dientamoeba fragilis) of about 80%, which may be considered for use as a benchmark value. We also used this tool to demonstrate that when pairs of specimens from one patient are pooled to create a single specimen, concordance between the results of the individual and pooled specimens is high. PMID:18448690
The perceived and actual diagnostic utility of veterinary cytological samples.
Skeldon, N; Dewhurst, E
2009-04-01
To establish the proportion of cytology samples sent to a commercial veterinary laboratory that yields diagnostically useful information in the context of current use and perceptions of cytology. Nine hundred and forty-five cytology submissions were retrospectively collected and categorised according to diagnostic utility. A survey into the use and perceptions of cytology was distributed at the British Small Animal Veterinary Association Congress 2008. A specific diagnosis was reached in 23.1 per cent of samples and a cytological diagnosis in 35.3 per cent. 22.4 per cent of samples yielded some useful information, but 19.2 per cent were unacceptable. Seventy-four participants in the survey took an average of 3.9 cytological samples per week, of which they examined 27.0 per cent in-house only, 21.6 per cent in-house before sending to an external laboratory and 51.4 per cent were sent externally without prior examination. "To obtain a definitive diagnosis" was the principal reason cited for performing cytology. Results suggest that cytology is underused and may be applied in an inappropriate context in the UK. It is hoped that illustrating the diagnostic outcome of samples received by a commercial laboratory will encourage increased, appropriate use of cytology.
Complex interferometry potential in case of sufficiently stable diagnostic system
NASA Astrophysics Data System (ADS)
Kalal, M.
2016-06-01
Classical interferometry is one of the key methods among active optical diagnostics. Its more advanced version, which allows recording and subsequent reconstruction of up to three sets of data using just one data object —a complex interferogram—was developed in the past and became known as complex interferometry. Employing this diagnostics, not only the usual phase shift, but also the amplitude of the probing beam as well as the fringe contrast (leading directly to the phase shift time derivative) can be reconstructed simultaneously from such a complex interferogram. In this paper it will be demonstrated that even in the case of a not particularly good diagnostic beam quality these three quantities can be reconstructed with a high degree of accuracy provided both the diagnostic beam as well as the corresponding optical line feature a reasonable stability. Such stability requirement is important as in an ideal case four shots need to be gradually recorded (one by one): the signal complex interferogram, the reference interferogram as well as the intensity structures of the signal and reference part of the diagnostic beam. Two examples of complex interferograms obtained in experiments will be analyzed: the laser produced plasma (spark in the air) and the high pressure gas jet. A general ray-tracing based iterative algorithm will be outlined in order to increase a precision of the index of refraction spatial profile taking into account refraction effects (omitted in the Abel inversion) and employing the original reconstructed phase shift and amplitude.
Adaptation of LASCA method for diagnostics of malignant tumours in laboratory animals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ul'yanov, S S; Laskavyi, V N; Glova, Alina B
The LASCA method is adapted for diagnostics of malignant neoplasms in laboratory animals. Tumours are studied in mice of Balb/c inbred line after inoculation of cells of syngeneic myeloma cell line Sp.2/0 Ag.8. The appropriateness of using the tLASCA method in tumour investigations is substantiated; its advantages in comparison with the sLASCA method are demonstrated. It is found that the most informative characteristic, indicating the presence of a tumour, is the fractal dimension of LASCA images.
Autoimmune liver serology: current diagnostic and clinical challenges.
Bogdanos, Dimitrios-P; Invernizzi, Pietro; Mackay, Ian-R; Vergani, Diego
2008-06-07
Liver-related autoantibodies are crucial for the correct diagnosis and classification of autoimmune liver diseases (AiLD), namely autoimmune hepatitis types 1 and 2 (AIH-1 and 2), primary biliary cirrhosis (PBC), and the sclerosing cholangitis variants in adults and children. AIH-1 is specified by anti-nuclear antibody (ANA) and smooth muscle antibody (SMA). AIH-2 is specified by antibody to liver kidney microsomal antigen type-1 (anti-LKM1) and anti-liver cytosol type 1 (anti-LC1). SMA, ANA and anti-LKM antibodies can be present in de-novo AIH following liver transplantation. PBC is specified by antimitochondrial antibodies (AMA) reacting with enzymes of the 2-oxo-acid dehydrogenase complexes (chiefly pyruvate dehydrogenase complex E2 subunit) and disease-specific ANA mainly reacting with nuclear pore gp210 and nuclear body sp100. Sclerosing cholangitis presents as at least two variants, first the classical primary sclerosing cholangitis (PSC) mostly affecting adult men wherein the only (and non-specific) reactivity is an atypical perinuclear antineutrophil cytoplasmic antibody (p-ANCA), also termed perinuclear anti-neutrophil nuclear antibodies (p-ANNA) and second the childhood disease called autoimmune sclerosing cholangitis (ASC) with serological features resembling those of type 1 AIH. Liver diagnostic serology is a fast-expanding area of investigation as new purified and recombinant autoantigens, and automated technologies such as ELISAs and bead assays, become available to complement (or even compete with) traditional immunofluorescence procedures. We survey for the first time global trends in quality assurance impacting as it does on (1) manufacturers/purveyors of kits and reagents, (2) diagnostic service laboratories that fulfill clinicians' requirements, and (3) the end-user, the physician providing patient care, who must properly interpret test results in the overall clinical context.
Autoimmune liver serology: Current diagnostic and clinical challenges
Bogdanos, Dimitrios P; Invernizzi, Pietro; Mackay, Ian R; Vergani, Diego
2008-01-01
Liver-related autoantibodies are crucial for the correct diagnosis and classification of autoimmune liver diseases (AiLD), namely autoimmune hepatitis types 1 and 2 (AIH-1 and 2), primary biliary cirrhosis (PBC), and the sclerosing cholangitis variants in adults and children. AIH-1 is specified by anti-nuclear antibody (ANA) and smooth muscle antibody (SMA). AIH-2 is specified by antibody to liver kidney microsomal antigen type-1 (anti-LKM1) and anti-liver cytosol type 1 (anti-LC1). SMA, ANA and anti-LKM antibodies can be present in de-novo AIH following liver transplantation. PBC is specified by antimitochondrial antibodies (AMA) reacting with enzymes of the 2-oxo-acid dehydrogenase complexes (chiefly pyruvate dehydrogenase complex E2 subunit) and disease-specific ANA mainly reacting with nuclear pore gp210 and nuclear body sp100. Sclerosing cholangitis presents as at least two variants, first the classical primary sclerosing cholangitis (PSC) mostly affecting adult men wherein the only (and non-specific) reactivity is an atypical perinuclear antineutrophil cytoplasmic antibody (p-ANCA), also termed perinuclear anti-neutrophil nuclear antibodies (p-ANNA) and second the childhood disease called autoimmune sclerosing cholangitis (ASC) with serological features resembling those of type 1 AIH. Liver diagnostic serology is a fast-expanding area of investigation as new purified and recombinant autoantigens, and automated technologies such as ELISAs and bead assays, become available to complement (or even compete with) traditional immunofluorescence procedures. We survey for the first time global trends in quality assurance impacting as it does on (1) manufacturers/purveyors of kits and reagents, (2) diagnostic service laboratories that fulfill clinicians’ requirements, and (3) the end-user, the physician providing patient care, who must properly interpret test results in the overall clinical context. PMID:18528935
Antigen-Bound and Free β-Amyloid Autoantibodies in Serum of Healthy Adults
Leirer, Vera Maria; von Arnim, Christine A. F.; Elbert, Thomas; Przybylski, Michael; Kolassa, Iris-Tatjana; Manea, Marilena
2012-01-01
Physiological β-amyloid autoantibodies (Aβ-autoantibodies) are currently investigated as potential diagnostic and therapeutic tools for Alzheimer’s disease (AD). In previous studies, their determination in serum and cerebrospinal fluid (CSF) using indirect ELISA has provided controversial results, which may be due to the presence of preformed Aβ antigen-antibody immune complexes. Based on the epitope specificity of the Aβ-autoantibodies, recently elucidated in our laboratory, we developed (a) a sandwich ELISA for the determination of circulating Aβ-IgG immune complexes and (b) an indirect ELISA for the determination of free Aβ-autoantibodies. This methodology was applied to the analysis of serum samples from healthy individuals within the age range of 18 to 89 years. Neuropsychological examination of the participants in this study indicated non-pathological, age-related cognitive decline, revealed especially by tests of visual memory and executive function, as well as speed-related tasks. The ELISA serum determinations showed significantly higher levels of Aβ-IgG immune complexes compared to free Aβ-autoantibodies, while no correlation with age or cognitive performance of the participants was found. PMID:22973459
Dalley, C; Basarir, H; Wright, J G; Fernando, M; Pearson, D; Ward, S E; Thokula, P; Krishnankutty, A; Wilson, G; Dalton, A; Talley, P; Barnett, D; Hughes, D; Porter, N R; Reilly, J T; Snowden, J A
2015-04-01
Specialist Integrated Haematological Malignancy Diagnostic Services (SIHMDS) were introduced as a standard of care within the UK National Health Service to reduce diagnostic error and improve clinical outcomes. Two broad models of service delivery have become established: 'co-located' services operating from a single-site and 'networked' services, with geographically separated laboratories linked by common management and information systems. Detailed systematic cost analysis has never been published on any established SIHMDS model. We used Activity Based Costing (ABC) to construct a cost model for our regional 'networked' SIHMDS covering a two-million population based on activity in 2011. Overall estimated annual running costs were £1 056 260 per annum (£733 400 excluding consultant costs), with individual running costs for diagnosis, staging, disease monitoring and end of treatment assessment components of £723 138, £55 302, £184 152 and £94 134 per annum, respectively. The cost distribution by department was 28.5% for haematology, 29.5% for histopathology and 42% for genetics laboratories. Costs of the diagnostic pathways varied considerably; pathways for myelodysplastic syndromes and lymphoma were the most expensive and the pathways for essential thrombocythaemia and polycythaemia vera being the least. ABC analysis enables estimation of running costs of a SIHMDS model comprised of 'networked' laboratories. Similar cost analyses for other SIHMDS models covering varying populations are warranted to optimise quality and cost-effectiveness in delivery of modern haemato-oncology diagnostic services in the UK as well as internationally. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Practical issues in implementing whole-genome-sequencing in routine diagnostic microbiology.
Rossen, J W A; Friedrich, A W; Moran-Gilad, J
2018-04-01
Next generation sequencing (NGS) is increasingly being used in clinical microbiology. Like every new technology adopted in microbiology, the integration of NGS into clinical and routine workflows must be carefully managed. To review the practical aspects of implementing bacterial whole genome sequencing (WGS) in routine diagnostic laboratories. Review of the literature and expert opinion. In this review, we discuss when and how to integrate whole genome sequencing (WGS) in the routine workflow of the clinical laboratory. In addition, as the microbiology laboratories have to adhere to various national and international regulations and criteria for their accreditation, we deliberate on quality control issues for using WGS in microbiology, including the importance of proficiency testing. Furthermore, the current and future place of this technology in the diagnostic hierarchy of microbiology is described as well as the necessity of maintaining backwards compatibility with already established methods. Finally, we speculate on the question of whether WGS can entirely replace routine microbiology in the future and the tension between the fact that most sequencers are designed to process multiple samples in parallel whereas for optimal diagnosis a one-by-one processing of the samples is preferred. Special reference is made to the cost and turnaround time of WGS in diagnostic laboratories. Further development is required to improve the workflow for WGS, in particular to shorten the turnaround time, reduce costs, and streamline downstream data analyses. Only when these processes reach maturity will reliance on WGS for routine patient management and infection control management become feasible, enabling the transformation of clinical microbiology into a genome-based and personalized diagnostic field. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
2012-01-01
Background Resource-limited tropical countries are home to numerous infectious pathogens of both human and zoonotic origin. A capability for early detection to allow rapid outbreak containment and prevent spread to non-endemic regions is severely impaired by inadequate diagnostic laboratory capacity, the absence of a “cold chain” and the lack of highly trained personnel. Building up detection capacity in these countries by direct replication of the systems existing in developed countries is not a feasible approach and instead requires “leapfrogging” to the deployment of the newest diagnostic systems that do not have the infrastructure requirements of systems used in developed countries. Methods A laboratory for molecular diagnostics of infectious agents was established in Bo, Sierra Leone with a hybrid solar/diesel/battery system to ensure stable power supply and a satellite modem to enable efficient communication. An array of room temperature stabilization and refrigeration technologies for reliable transport and storage of reagents and biological samples were also tested to ensure sustainable laboratory supplies for diagnostic assays. Results The laboratory demonstrated its operational proficiency by conducting an investigation of a suspected avian influenza outbreak at a commercial poultry farm at Bo using broad range resequencing microarrays and real time RT-PCR. The results of the investigation excluded influenza viruses as a possible cause of the outbreak and indicated a link between the outbreak and the presence of Klebsiella pneumoniae. Conclusions This study demonstrated that by application of a carefully selected set of technologies and sufficient personnel training, it is feasible to deploy and effectively use a broad-range infectious pathogen detection technology in a severely resource-limited setting. PMID:22759725
Hazardous Waste Cleanup: Ortho-Clinical Diagnostics, Raritan, New Jersey
Ortho-Clinical Diagnostics (OCD) is an administration and manufacturing facility located at 1001 U.S. Route 202 North in Raritan Borough, Somerset County, New Jersey. The facility manufactures hospital and laboratory reagents used primarily for blood
Painful Shoulder in Swimmers: A Diagnostic Challenge.
ERIC Educational Resources Information Center
McMaster, William C.
1986-01-01
This article discusses the incidence, diagnosis, and treatment of painful shoulder in swimmers, including: regional problems that can cause shoulder pain; physical, clinical, and laboratory tests for diagnostic use; and approaches to management of the problem. (Author/CB)
Metabolomics for laboratory diagnostics.
Bujak, Renata; Struck-Lewicka, Wiktoria; Markuszewski, Michał J; Kaliszan, Roman
2015-09-10
Metabolomics is an emerging approach in a systems biology field. Due to continuous development in advanced analytical techniques and in bioinformatics, metabolomics has been extensively applied as a novel, holistic diagnostic tool in clinical and biomedical studies. Metabolome's measurement, as a chemical reflection of a current phenotype of a particular biological system, is nowadays frequently implemented to understand pathophysiological processes involved in disease progression as well as to search for new diagnostic or prognostic biomarkers of various organism's disorders. In this review, we discussed the research strategies and analytical platforms commonly applied in the metabolomics studies. The applications of the metabolomics in laboratory diagnostics in the last 5 years were also reviewed according to the type of biological sample used in the metabolome's analysis. We also discussed some limitations and further improvements which should be considered taking in mind potential applications of metabolomic research and practice. Copyright © 2014 Elsevier B.V. All rights reserved.
Soft x-ray power diagnostic improvements at the Omega Laser Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorce, C.; Schein, J.; Weber, F.
2006-10-15
Soft x-ray power diagnostics are essential for evaluating high temperature laser plasma experiments. The Dante soft x-ray spectrometer, a core diagnostic for radiation flux and temperature measurements of Hohlraums, installed on the Omega Laser Facility at the Laboratory for Laser Energetics has recently undergone a series of upgrades. Work performed at Brookhaven National Laboratory for the development of the National Ignition Facility (NIF) Dante spectrometer enables the Omega Dante to offer a total of 18 absolutely calibrated channels in the energy range from 50 eV to 20 keV. This feature provides Dante with the capability to measure higher, NIF relevant,more » radiation temperatures with increased accuracy including a differentiation of higher energy radiation such as the Au M and L bands. Diagnostic monitoring using experimental data from directly driven Au spherical shots is discussed.« less
Status and test report on the LANL-Boeing APLE/HPO flying-wire beam-profile monitor. Status report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilke, M.; Barlow, D.; Fortgang, C.
1994-07-01
The High-Power Oscillator (HPO) demonstration of the Average Power Laser Experiment (APLE) is a collaboration by Los Alamos National Laboratory and Boeing to demonstrate a 10 kW average power, 10 {mu}m free electron laser (FEL). As part of the collaboration, Los Alamos National Laboratory (LANL) is responsible for many of the electron beam diagnostics in the linac, transport, and laser sections. Because of the high duty factor and power of the electron beam, special diagnostics are required. This report describes the flying wire diagnostic required to monitor the beam profile during high-power, high-duty operation. The authors describe the diagnostic andmore » prototype tests on the Los Alamos APLE Prototype Experiment (APEX) FEL. They also describe the current status of the flying wires being built for APLE.« less
Vinuesa, Víctor; Borrás, Rafael; Briones, María Luisa; Clari, María Ángeles; Cresencio, Vicenta; Giménez, Estela; Muñoz, Carmen; Oltra, Rosa; Servera, Emilio; Scheelje, Talia; Tornero, Carlos; Navarro, David
2018-05-01
The potential impact of routine real-time PCR testing of respiratory specimens from patients with presumptive tuberculosis in terms of diagnostic accuracy and time to tuberculosis treatment inception in low-prevalence settings remains largely unexplored. We conducted a prospective intervention cohort study. Respiratory specimens from 1,020 patients were examined by acid-fast bacillus smear microscopy, tested by a real-time Mycobacterium tuberculosis complex PCR assay (Abbott RealTi me MTB PCR), and cultured in mycobacterial media. Seventeen patients tested positive by PCR (5 were acid-fast bacillus smear positive and 12 acid-fast bacillus smear negative), and Mycobacterium tuberculosis was recovered from cultures for 12 of them. Patients testing positive by PCR and negative by culture ( n = 5) were treated and deemed to have responded to antituberculosis therapy. There were no PCR-negative/culture-positive cases, and none of the patients testing positive for nontuberculous mycobacteria ( n = 20) yielded a positive PCR result. The data indicated that routine testing of respiratory specimens from patients with presumptive tuberculosis by the RealTi me MTB PCR assay improves the tuberculosis diagnostic yield and may reduce the time to antituberculosis treatment initiation. On the basis of our data, we propose a novel mycobacterial laboratory algorithm for tuberculosis diagnosis. Copyright © 2018 American Society for Microbiology.
... eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; 2013:878-880. Klemm ... Diagnosis and Management by Laboratory Methods . 23rd ed. St Louis, MO: Elsevier; 2017:chap 15. Kliegman RM, ...
Recommendations for accreditation of laboratories in molecular biology of hematologic malignancies.
Flandrin-Gresta, Pascale; Cornillet, Pascale; Hayette, Sandrine; Gachard, Nathalie; Tondeur, Sylvie; Mauté, Carole; Cayuela, Jean-Michel
2015-01-01
Over recent years, the development of molecular biology techniques has improved the hematological diseases diagnostic and follow-up. Consequently, these techniques are largely used in the biological screening of these diseases; therefore the Hemato-oncology molecular diagnostics laboratories must be actively involved in the accreditation process according the ISO 15189 standard. The French group of molecular biologists (GBMHM) provides requirements for the implementation of quality assurance for the medical molecular laboratories. This guideline states the recommendations for the pre-analytical, analytical (methods validation procedures, quality controls, reagents), and post-analytical conditions. In addition, herein we state a strategy for the internal quality control management. These recommendations will be regularly updated.
Interpreting the Laboratory Reports for Vit D.
Sarmah, Devajit; Sharma, Booloo
2014-09-01
Importance for Vit D estimation has increased in the recent years due to its link to various diseases. Measurements of Vit D by different diagnostic laboratories is however not uniform. There is variation pertaining to assay methodology and also variation in the measurement of different metabolites of Vit D. There are also various confounders which influence Vit D assays and which in most instances are overlooked. Also a matter of concern regarding Vit D assays is the lack of assay standardisation. These factors contribute to the variation in the reports generated by the diagnostic laboratories. Therefore interpretation of Vit D reports needs proper understanding of these interfering factors and further reports need to be correlated substantially with the clinical findings.
Antonelli, Giorgia; Padoan, Andrea; Aita, Ada; Sciacovelli, Laura; Plebani, Mario
2017-08-28
Background The International Standard ISO 15189 is recognized as a valuable guide in ensuring high quality clinical laboratory services and promoting the harmonization of accreditation programmes in laboratory medicine. Examination procedures must be verified in order to guarantee that their performance characteristics are congruent with the intended scope of the test. The aim of the present study was to propose a practice model for implementing procedures employed for the verification of validated examination procedures already used for at least 2 years in our laboratory, in agreement with the ISO 15189 requirement at the Section 5.5.1.2. Methods In order to identify the operative procedure to be used, approved documents were identified, together with the definition of performance characteristics to be evaluated for the different methods; the examination procedures used in laboratory were analyzed and checked for performance specifications reported by manufacturers. Then, operative flow charts were identified to compare the laboratory performance characteristics with those declared by manufacturers. Results The choice of performance characteristics for verification was based on approved documents used as guidance, and the specific purpose tests undertaken, a consideration being made of: imprecision and trueness for quantitative methods; diagnostic accuracy for qualitative methods; imprecision together with diagnostic accuracy for semi-quantitative methods. Conclusions The described approach, balancing technological possibilities, risks and costs and assuring the compliance of the fundamental component of result accuracy, appears promising as an easily applicable and flexible procedure helping laboratories to comply with the ISO 15189 requirements.
Laboratory Response to Ebola - West Africa and United States.
Sealy, Tara K; Erickson, Bobbie R; Taboy, Céline H; Ströher, Ute; Towner, Jonathan S; Andrews, Sharon E; Rose, Laura E; Weirich, Elizabeth; Lowe, Luis; Klena, John D; Spiropoulou, Christina F; Rayfield, Mark A; Bird, Brian H
2016-07-08
The 2014-2016 Ebola virus disease (Ebola) epidemic in West Africa highlighted the need to maintain organized laboratory systems or networks that can be effectively reorganized to implement new diagnostic strategies and laboratory services in response to large-scale events. Although previous Ebola outbreaks enabled establishment of critical laboratory practice safeguards and diagnostic procedures, this Ebola outbreak in West Africa highlighted the need for planning and preparedness activities that are better adapted to emerging pathogens or to pathogens that have attracted little commercial interest. The crisis underscored the need for better mechanisms to streamline development and evaluation of new diagnostic assays, transfer of material and specimens between countries and organizations, and improved processes for rapidly deploying health workers with specific laboratory expertise. The challenges and events of the outbreak forced laboratorians to examine not only the comprehensive capacities of existing national laboratory systems to recognize and respond to events, but also their sustainability over time and the mechanisms that need to be pre-established to ensure effective response. Critical to this assessment was the recognition of how response activities (i.e., infrastructure support, logistics, and workforce supplementation) can be used or repurposed to support the strengthening of national laboratory systems during the postevent transition to capacity building and recovery. This report compares CDC's domestic and international laboratory response engagements and lessons learned that can improve future responses in support of the International Health Regulations and Global Health Security Agenda initiatives.The activities summarized in this report would not have been possible without collaboration with many U.S. and international partners (http://www.cdc.gov/vhf/ebola/outbreaks/2014-west-africa/partners.html).
Jacobsen, Sonja; Patel, Pranav; Rieger, Toni; Eickmann, Markus; Becker, Stephan; Günther, Stephan; Naidoo, Dhamari; Schrick, Livia; Keeren, Kathrin; Targosz, Angelina; Teichmann, Anette; Formenty, Pierre; Niedrig, Matthias
2017-01-01
During the recent Ebola outbreak in West Africa several international mobile laboratories were deployed to the mainly affected countries Guinea, Sierra Leone and Liberia to provide ebolavirus diagnostic capacity. Additionally, imported cases and small outbreaks in other countries required global preparedness for Ebola diagnostics. Detection of viral RNA by reverse transcription polymerase chain reaction has proven effective for diagnosis of ebolavirus disease and several assays are available. However, reliability of these assays is largely unknown and requires serious evaluation. Therefore, a proficiency test panel of 11 samples was generated and distributed on a global scale. Panels were analyzed by 83 expert laboratories and 106 data sets were returned. From these 78 results were rated optimal and 3 acceptable, 25 indicated need for improvement. While performance of the laboratories deployed to West Africa was superior to the overall performance there was no significant difference between the different assays applied. PMID:28459810
Ellerbrok, Heinz; Jacobsen, Sonja; Patel, Pranav; Rieger, Toni; Eickmann, Markus; Becker, Stephan; Günther, Stephan; Naidoo, Dhamari; Schrick, Livia; Keeren, Kathrin; Targosz, Angelina; Teichmann, Anette; Formenty, Pierre; Niedrig, Matthias
2017-05-01
During the recent Ebola outbreak in West Africa several international mobile laboratories were deployed to the mainly affected countries Guinea, Sierra Leone and Liberia to provide ebolavirus diagnostic capacity. Additionally, imported cases and small outbreaks in other countries required global preparedness for Ebola diagnostics. Detection of viral RNA by reverse transcription polymerase chain reaction has proven effective for diagnosis of ebolavirus disease and several assays are available. However, reliability of these assays is largely unknown and requires serious evaluation. Therefore, a proficiency test panel of 11 samples was generated and distributed on a global scale. Panels were analyzed by 83 expert laboratories and 106 data sets were returned. From these 78 results were rated optimal and 3 acceptable, 25 indicated need for improvement. While performance of the laboratories deployed to West Africa was superior to the overall performance there was no significant difference between the different assays applied.
New Mexico Small Business Assistance (NMSBA) September 2016 Advisory Council Update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larkin, Ariana Kayla
This is an update on two projects headed by Los Alamos National Laboratory and Sandia National Laboratories. The two projects are: The Electrochemical Based Gas Analyzer for Automotive Diagnostic and Maximizing the Production of High Value and High Demand Guar Gum on Marginal Lands in New Mexico. The Electrochemical Based Gas Analyzer for Automotive Diagnostic NMSBA leveraged project is made up of Albuquerque companies, Automotive Test Solutions, Inc. (ATS), ATS Mobile Diagnostics and Thoma Technologies and Los Alamos small business, VI Control Systems, to develop a new sensor system for the automotive industry. The Guar Gum NMSBA Leveraged Project beganmore » in January 2016 with the goal to develop biotechnology to enable a genetic modification of prairie cordgrass, a renewable feedstock for bioenergy and bio-manufacturing. In the long term, the companies hope to use the technology to bio-manufacture high value products in the stem of the plant. This document describes the laboratories' cooperation with small businesses on these projects.« less
Glass-Kaastra, Shiona K.; Pearl, David L.; Reid-Smith, Richard J.; McEwen, Beverly; Slavic, Durda; McEwen, Scott A.; Fairles, Jim
2014-01-01
Antimicrobial susceptibility data on Escherichia coli F4, Pasteurella multocida, and Streptococcus suis isolates from Ontario swine (January 1998 to October 2010) were acquired from a comprehensive diagnostic veterinary laboratory in Ontario, Canada. In relation to the possible development of a surveillance system for antimicrobial resistance, data were assessed for ease of management, completeness, consistency, and applicability for temporal and spatial statistical analyses. Limited farm location data precluded spatial analyses and missing demographic data limited their use as predictors within multivariable statistical models. Changes in the standard panel of antimicrobials used for susceptibility testing reduced the number of antimicrobials available for temporal analyses. Data consistency and quality could improve over time in this and similar diagnostic laboratory settings by encouraging complete reporting with sample submission and by modifying database systems to limit free-text data entry. These changes could make more statistical methods available for disease surveillance and cluster detection. PMID:24688133
Glass-Kaastra, Shiona K; Pearl, David L; Reid-Smith, Richard J; McEwen, Beverly; Slavic, Durda; McEwen, Scott A; Fairles, Jim
2014-04-01
Antimicrobial susceptibility data on Escherichia coli F4, Pasteurella multocida, and Streptococcus suis isolates from Ontario swine (January 1998 to October 2010) were acquired from a comprehensive diagnostic veterinary laboratory in Ontario, Canada. In relation to the possible development of a surveillance system for antimicrobial resistance, data were assessed for ease of management, completeness, consistency, and applicability for temporal and spatial statistical analyses. Limited farm location data precluded spatial analyses and missing demographic data limited their use as predictors within multivariable statistical models. Changes in the standard panel of antimicrobials used for susceptibility testing reduced the number of antimicrobials available for temporal analyses. Data consistency and quality could improve over time in this and similar diagnostic laboratory settings by encouraging complete reporting with sample submission and by modifying database systems to limit free-text data entry. These changes could make more statistical methods available for disease surveillance and cluster detection.
Point-of-care diagnostics: extending the laboratory network to reach the last mile.
Drain, Paul K; Rousseau, Christine
2017-03-01
More point-of-care (POC) diagnostic tests are becoming available for HIV diagnosis and treatment in resource-limited settings. These novel technologies have the potential to foster decentralized HIV care and treatment for the benefit of clinical laboratories, HIV clinics, and HIV-infected patients. There continue to be many business, technological, and operational challenges that limit product development and regulatory approval, which limits products available for the required operational and cost-effectiveness studies and delays policy adoption and implementation. Although the rapid HIV diagnostic test has been widely successful, the pathways for POC CD4 cell count and HIV viral load assay analyzers have been more challenging. We describe significant hurdles for product development, approval, and implementation, which include the business case, technical development, clinical impact, and integrating laboratory and clinical networks. The objective of this review is to highlight the obstacles for developing and implementing appropriate strategies for POC HIV testing assays to improve the clinical services for HIV-infected patients in resource-limited settings.
Screening and syndromic approaches to identify gonorrhea and chlamydial infection among women.
Sloan, N L; Winikoff, B; Haberland, N; Coggins, C; Elias, C
2000-03-01
The standard diagnostic tools to identify sexually transmitted infections are often expensive and have laboratory and infrastructure requirements that make them unavailable to family planning and primary health-care clinics in developing countries. Therefore, inexpensive, accessible tools that rely on symptoms, signs, and/or risk factors have been developed to identify and treat reproductive tract infections without the need for laboratory diagnostics. Studies were reviewed that used standard diagnostic tests to identify gonorrhea and cervical chlamydial infection among women and that provided adequate information about the usefulness of the tools for screening. Aggregation of the studies' results suggest that risk factors, algorithms, and risk scoring for syndromic management are poor indicators of gonorrhea and chlamydial infection in samples of both low and high prevalence and, consequently, are not effective mechanisms with which to identify or manage these conditions. The development and evaluation of other approaches to identify gonorrhea and chlamydial infections, including inexpensive and simple laboratory screening tools, periodic universal treatment, and other alternatives must be given priority.
Ciardo, Diana E; Lucke, Katja; Imhof, Alex; Bloemberg, Guido V; Böttger, Erik C
2010-08-01
The implementation of internal transcribed spacer (ITS) sequencing for routine identification of molds in the diagnostic mycology laboratory was analyzed in a 5-year study. All mold isolates (n = 6,900) recovered in our laboratory from 2005 to 2009 were included in this study. According to a defined work flow, which in addition to troublesome phenotypic identification takes clinical relevance into account, 233 isolates were subjected to ITS sequence analysis. Sequencing resulted in successful identification for 78.6% of the analyzed isolates (57.1% at species level, 21.5% at genus level). In comparison, extended in-depth phenotypic characterization of the isolates subjected to sequencing achieved taxonomic assignment for 47.6% of these, with a mere 13.3% at species level. Optimization of DNA extraction further improved the efficacy of molecular identification. This study is the first of its kind to testify to the systematic implementation of sequence-based identification procedures in the routine workup of mold isolates in the diagnostic mycology laboratory.
Miniature Time-of-Flight Mass Spectrometer
NASA Technical Reports Server (NTRS)
Potember, Richard S.
1999-01-01
Major advances must occur to protect astronauts from prolonged periods in near-zero gravity and high radiation associated with extended space travel. The dangers of living in space must be thoroughly understood and methods developed to reverse those effects that cannot be avoided. Six of the seven research teams established by the National Space Biomedical Research Institute (NSBRI) are studying biomedical factors for prolonged space travel to deliver effective countermeasures. To develop effective countermeasures, each of these teams require identification of and quantitation of complex pharmacological, hormonal, and growth factor compounds (biomarkers) in humans and in experimental animals to develop an in-depth knowledge of the physiological changes associated with space travel. At present, identification of each biomarker requires a separate protocol. Many of these procedures are complicated and the identification of each biomarker requires a separate protocol and associated laboratory equipment. To carry all of this equipment and chemicals on a spacecraft would require a complex clinical laboratory; and it would occupy much of the astronauts time. What is needed is a small, efficient, broadband medical diagnostic instrument to rapidly identify important biomarkers for human space exploration. The Miniature Time-Of- Flight Mass Spectrometer Project in the Technology Development Team is developing a small, high resolution, time-of-flight mass spectrometer (TOFMS) to quantitatively measure biomarkers for human space exploration. Virtues of the JHU/APL TOFMS technologies reside in the promise for a small (less than one cubic ft), lightweight (less than 5 kg), low-power (less than 50 watts), rugged device that can be used continuously with advanced signal processing diagnostics. To date, the JHU/APL program has demonstrated mass capability from under 100 to beyond 10,000 atomic mass units (amu) in a very small, low power prototype for biological analysis. Further, the electronic nature of the TOFMS output makes it ideal for rapid telemetry to earth for in-depth analysis by ground support teams.
Antidiuretic hormone blood test
... eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; 2013:146. Guber HA, ... Diagnosis and Management by Laboratory Methods . 23rd ed. St Louis, MO: Elsevier; 2017:chap 24. Oh MS, ...
... eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; 2013:654-655. Fagoaga ... Diagnosis and Management by Laboratory Methods . 23rd ed. St Louis, MO: Elsevier; 2017:chap 49. Inman RD. ...
Kerényi, Adrienne; Beke Debreceni, Ildikó; Oláh, Zsolt; Ilonczai, Péter; Bereczky, Zsuzsanna; Nagy, Béla; Muszbek, László; Kappelmayer, János
2017-09-01
Heparin-induced thrombocytopenia (HIT) is a severe side effect of heparin treatment caused by platelet activating IgG antibodies generated against the platelet factor 4 (PF4)-heparin complex. Thrombocytopenia and thrombosis are the leading clinical symptoms of HIT. The clinical pretest probability of HIT was evaluated by the 4T score system. Laboratory testing of HIT was performed by immunological detection of antibodies against PF4-heparin complex (EIA) and two functional assays. Heparin-dependent activation of donor platelets by patient plasma was detected by flow cytometry. Increased binding of Annexin-V to platelets and elevated number of platelet-derived microparticles (PMP) were the indicators of platelet activation. EIA for IgG isotype HIT antibodies was performed in 405 suspected HIT patients. Based on negative EIA results, HIT was excluded in 365 (90%) of cases. In 40 patients with positive EIA test result functional tests were performed. Platelet activating antibodies were detected in 17 cases by Annexin V binding. PMP count analysis provided nearly identical results. The probability of a positive flow cytometric assay result was higher in patients with elevated antibody titer. 71% of patients with positive EIA and functional assay had thrombosis. EIA is an important first line laboratory test in the diagnosis of HIT; however, HIT must be confirmed by a functional test. Annexin V binding and PMP assays using flow cytometry are functional HIT tests convenient in a clinical diagnostic laboratory. The positive results of functional assays may predict the onset of thrombosis. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.
Messacar, Kevin; Parker, Sarah K; Todd, James K; Dominguez, Samuel R
2017-03-01
New rapid molecular diagnostic technologies for infectious diseases enable expedited accurate microbiological diagnoses. However, diagnostic stewardship and antimicrobial stewardship are necessary to ensure that these technologies conserve, rather than consume, additional health care resources and optimally affect patient care. Diagnostic stewardship is needed to implement appropriate tests for the clinical setting and to direct testing toward appropriate patients. Antimicrobial stewardship is needed to ensure prompt appropriate clinical action to translate faster diagnostic test results in the laboratory into improved outcomes at the bedside. This minireview outlines the roles of diagnostic stewardship and antimicrobial stewardship in the implementation of rapid molecular infectious disease diagnostics. Copyright © 2017 American Society for Microbiology.
Initial Public Health Laboratory Response After Hurricane Maria - Puerto Rico, 2017.
Concepción-Acevedo, Jeniffer; Patel, Anita; Luna-Pinto, Carolina; Peña, Rafael González; Cuevas Ruiz, Rosa Ivette; Arbolay, Héctor Rivera; Toro, Mayra; Deseda, Carmen; De Jesus, Victor R; Ribot, Efrain; Gonzalez, Jennifer-Quiñones; Rao, Gouthami; De Leon Salazar, Alfonsina; Ansbro, Marisela; White, Brunilís B; Hardy, Margaret C; Georgi, Joaudimir Castro; Stinnett, Rita; Mercante, Alexandra M; Lowe, David; Martin, Haley; Starks, Angela; Metchock, Beverly; Johnston, Stephanie; Dalton, Tracy; Joglar, Olga; Stafford, Cortney; Youngblood, Monica; Klein, Katherine; Lindstrom, Stephen; Berman, LaShondra; Galloway, Renee; Schafer, Ilana J; Walke, Henry; Stoddard, Robyn; Connelly, Robin; McCaffery, Elaine; Rowlinson, Marie-Claire; Soroka, Stephen; Tranquillo, Darin T; Gaynor, Anne; Mangal, Chris; Wroblewski, Kelly; Muehlenbachs, Atis; Salerno, Reynolds M; Lozier, Matthew; Sunshine, Brittany; Shapiro, Craig; Rose, Dale; Funk, Renee; Pillai, Satish K; O'Neill, Eduardo
2018-03-23
Hurricane Maria made landfall in Puerto Rico on September 20, 2017, causing major damage to infrastructure and severely limiting access to potable water, electric power, transportation, and communications. Public services that were affected included operations of the Puerto Rico Department of Health (PRDOH), which provides critical laboratory testing and surveillance for diseases and other health hazards. PRDOH requested assistance from CDC for the restoration of laboratory infrastructure, surveillance capacity, and diagnostic testing for selected priority diseases, including influenza, rabies, leptospirosis, salmonellosis, and tuberculosis. PRDOH, CDC, and the Association of Public Health Laboratories (APHL) collaborated to conduct rapid needs assessments and, with assistance from the CDC Foundation, implement a temporary transport system for shipping samples from Puerto Rico to the continental United States for surveillance and diagnostic and confirmatory testing. This report describes the initial laboratory emergency response and engagement efforts among federal, state, and nongovernmental partners to reestablish public health laboratory services severely affected by Hurricane Maria. The implementation of a sample transport system allowed Puerto Rico to reinitiate priority infectious disease surveillance and laboratory testing for patient and public health interventions, while awaiting the rebuilding and reinstatement of PRDOH laboratory services.
Dekmezian, Mhair; Beal, Stacy G; Damashek, Mary Jane; Benavides, Raul; Dhiman, Neelam
2015-04-01
Successful performance and execution of rapid diagnostics in a clinical laboratory hinges heavily on careful validation, accurate and timely communication of results, and real-time quality monitoring. Laboratories must develop strategies to integrate diagnostics with stewardship and evidence-based clinical practice guidelines. We present a collaborative SUCCESS model for execution and monitoring of rapid sepsis diagnostics to facilitate timely treatment. Six months after execution of the Verigene Gram-Positive Blood Culture (BC-GP) and the AdvanDx PNA-FISH assays, data were collected on 579 and 28 episodes of bacteremia and fungemia, respectively. Clinical testing was executed using a SUCCESS model comprising the following components: stewardship, utilization of resources, core strategies, concierge services, education, support, and surveillance. Stewardship needs were identified by evaluating the specialty services benefiting from new testing. Utilization of resources was optimized by reviewing current treatment strategies and antibiogram and formulary options. Core strategies consisted of input from infectious disease leadership, pharmacy, and laboratory staff. Concierge services included automated Micro-eUpdate and physician-friendly actionable reports. Education modules were user-specific, and support was provided through a dedicated 24/7 microbiology hotline. Surveillance was performed by daily audit by the director. Using the SUCCESS model, the turnaround time for the detailed report with actionable guidelines to the physician was ∼3 hours from the time of culture positivity. The overall correlation between rapid methods and culture was 94% (546/579). Discrepant results were predominantly contaminants such as a coagulase-negative staphylococci or viridans streptococci in mixed cultures. SUCCESS is a cost-effective and easily adaptable model for clinical laboratories with limited stewardship resources.
Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L
2008-11-01
Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.
Vallée, Isabelle; Macé, Pauline; Forbes, Lorry; Scandrett, Brad; Durand, Benoit; Gajadhar, Alvin; Boireau, Pascal
2007-07-01
Routine diagnosis of animal trichinellosis for food safety and trade relies on a method of artificial digestion to free Trichinella muscle larvae from meat for subsequent identification by microscopy. As part of a quality control system, the French National Reference Laboratory (NRL) initiated ring trials to determine the sensitivity of the test performed in the 72 routine diagnostic laboratories in France. A method was devised to obtain calibrated meat samples containing known numbers of capsules with Trichinella spiralis muscle larvae. This method was based on an incomplete artificial digestion of Trichinella-infected mice carcasses to allow the collection of intact Trichinella capsules. Capsules were placed into a meatball of 100 +/- 2 g of pork and horsemeat to produce proficiency samples. Three categories of samples were prepared: small (3 to 5 capsules), medium (7 to 10), and large (12 to 15). The sensitivity was expressed as the percentage of muscle larvae recovered from each proficiency sample. Reproducibility was tested with ring trials organized between two NRLs (France and Canada), and a reference sensitivity of 84.9% was established. National ring trials were then organized in France, with the 72 routine diagnostic laboratories each receiving four proficiency samples per session. After five sessions, an improvement in the digest test sensitivity was observed. Results at the fifth session indicated sensitivities of 78.60% +/- 23.70%, 81.19% +/- 19.59%, and 80.52% +/- 14.71% muscle larvae for small, medium, and large samples, respectively. This study supports the use of proficiency samples to accurately evaluate the performance of routine diagnostic laboratories that conduct digestion tests for animal trichinellosis diagnosis.
OIE Collaborating Centre for Biorisk Management Strategic Plan.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brass, Van Hildren
Due to efforts by individual nations and the international community to monitor and control natural occurring outbreaks of animal and zoonotic diseases, any number and variety of select agents and especially dangerous pathogens can be found at diagnostic laboratories around the world. Diagnostic testing is a crucial aspect of disease surveillance, but the organized collection and testing of diagnostic samples from the animal and human population at laboratories has created a repository of disease agents and toxins that could cause serious harm if released or acquired by nefarious means. The delicate balance between public health disease surveillance and the managementmore » of biorisks at facilities utilized in surveillance is a necessary goal of veterinary public health.« less
A review of current and future molecular diagnostic tests for use in the microbiology laboratory.
Jannes, Geert; De Vos, Daniel
2006-01-01
Nucleic acid-based diagnostics gradually are replacing or complementing culture-based, biochemical, and immunological assays in routine microbiology laboratories. Similar to conventional tests, the first-generation deoxyribonucleic acid assays determined only a single analyte. Recent improvements in detection technologies have paved the way for the development of multiparameter assays using macroarrays or micro-arrays, while the introduction of closed-tube real-time polymerase chain reaction systems has resulted in the development of rapid microbial diagnostics with a reduced contamination risk. The use of these new molecular technologies is not restricted to detection and identification of microbial pathogens but also can be used for genotyping, allowing one to determine antibiotic resistance or to perform microbial fingerprinting.
Space Laboratory on a Table Top: A Next Generative ECLSS design and diagnostic tool
NASA Technical Reports Server (NTRS)
Ramachandran, N.
2005-01-01
This paper describes the development plan for a comprehensive research and diagnostic tool for aspects of advanced life support systems in space-based laboratories. Specifically it aims to build a high fidelity tabletop model that can be used for the purpose of risk mitigation, failure mode analysis, contamination tracking, and testing reliability. We envision a comprehensive approach involving experimental work coupled with numerical simulation to develop this diagnostic tool. It envisions a 10% scale transparent model of a space platform such as the International Space Station that operates with water or a specific matched index of refraction liquid as the working fluid. This allows the scaling of a 10 ft x 10 ft x 10 ft room with air flow to 1 ft x 1 ft x 1 ft tabletop model with water/liquid flow. Dynamic similitude for this length scale dictates model velocities to be 67% of full-scale and thereby the time scale of the model to represent 15% of the full- scale system; meaning identical processes in the model are completed in 15% of the full- scale-time. The use of an index matching fluid (fluid that matches the refractive index of cast acrylic, the model material) allows making the entire model (with complex internal geometry) transparent and hence conducive to non-intrusive optical diagnostics. So using such a system one can test environment control parameters such as core flows (axial flows), cross flows (from registers and diffusers), potential problem areas such as flow short circuits, inadequate oxygen content, build up of other gases beyond desirable levels, test mixing processes within the system at local nodes or compartments and assess the overall system performance. The system allows quantitative measurements of contaminants introduced in the system and allows testing and optimizing the tracking process and removal of contaminants. The envisaged system will be modular and hence flexible for quick configuration change and subsequent testing. The data and inferences from the tests will allow for improvements in the development and design of next generation life support systems and configurations. Preliminary experimental and modeling work in this area will be presented. This involves testing of a single inlet-exit model with detailed 3-D flow visualization and quantitative diagnostics and computational modeling of the system.
McDonald, William C; Banerji, Nilanjana; McDonald, Kelsey N; Ho, Bridget; Macias, Virgilia; Kajdacsy-Balla, Andre
2017-01-01
-Pituitary adenoma classification is complex, and diagnostic strategies vary greatly from laboratory to laboratory. No optimal diagnostic algorithm has been defined. -To develop a panel of immunohistochemical (IHC) stains that provides the optimal combination of cost, accuracy, and ease of use. -We examined 136 pituitary adenomas with stains of steroidogenic factor 1 (SF-1), Pit-1, anterior pituitary hormones, cytokeratin CAM5.2, and α subunit of human chorionic gonadotropin. Immunohistochemical staining was scored using the Allred system. Adenomas were assigned to a gold standard class based on IHC results and available clinical and serologic information. Correlation and cluster analyses were used to develop an algorithm for parsimoniously classifying adenomas. -The algorithm entailed a 1- or 2-step process: (1) a screening step consisting of IHC stains for SF-1, Pit-1, and adrenocorticotropic hormone; and (2) when screening IHC pattern and clinical history were not clearly gonadotrophic (SF-1 positive only), corticotrophic (adrenocorticotropic hormone positive only), or IHC null cell (negative-screening IHC), we subsequently used IHC for prolactin, growth hormone, thyroid-stimulating hormone, and cytokeratin CAM5.2. -Comparison between diagnoses generated by our algorithm and the gold standard diagnoses showed excellent agreement. When compared with a commonly used panel using 6 IHC for anterior pituitary hormones plus IHC for a low-molecular-weight cytokeratin in certain tumors, our algorithm uses approximately one-third fewer IHC stains and detects gonadotroph adenomas with greater sensitivity.
Point-of-care technologies for molecular diagnostics using a drop of blood.
Song, Yujun; Huang, Yu-Yen; Liu, Xuewu; Zhang, Xiaojing; Ferrari, Mauro; Qin, Lidong
2014-03-01
Molecular diagnostics is crucial for prevention, identification, and treatment of disease. Traditional technologies for molecular diagnostics using blood are limited to laboratory use because they rely on sample purification and sophisticated instruments, are labor and time intensive, expensive, and require highly trained operators. This review discusses the frontiers of point-of-care (POC) diagnostic technologies using a drop of blood obtained from a finger prick. These technologies, including emerging biotechnologies, nanotechnologies, and microfluidics, hold the potential for rapid, accurate, and inexpensive disease diagnostics. Copyright © 2014 Elsevier Ltd. All rights reserved.
Molecular diagnostics: the changing culture of medical microbiology.
Bullman, Susan; Lucey, Brigid; Sleator, Roy D
2012-01-01
Diagnostic molecular biology is arguably the fastest growing area in current laboratory-based medicine. Growth of the so called 'omics' technologies has, over the last decade, led to a gradual migration away from the 'one test, one pathogen' paradigm, toward multiplex approaches to infectious disease diagnosis, which have led to significant improvements in clinical diagnostics and ultimately improved patient care.
Goller, K V; Dill, V; Madi, M; Martin, P; Van der Stede, Y; Vandenberge, V; Haas, B; Van Borm, S; Koenen, F; Kasanga, C J; Ndusilo, N; Beer, M; Liu, L; Mioulet, V; Armson, B; King, D P; Fowler, V L
2018-04-01
Highly contagious transboundary animal diseases such as foot-and-mouth disease (FMD) are major threats to the productivity of farm animals. To limit the impact of outbreaks and to take efficient steps towards a timely control and eradication of the disease, rapid and reliable diagnostic systems are of utmost importance. Confirmatory diagnostic assays are typically performed by experienced operators in specialized laboratories, and access to this capability is often limited in the developing countries with the highest disease burden. Advances in molecular technologies allow implementation of modern and reliable techniques for quick and simple pathogen detection either in basic laboratories or even at the pen-side. Here, we report on a study to evaluate a fully automated cartridge-based real-time RT-PCR diagnostic system (Enigma MiniLab ® ) for the detection of FMD virus (FMDV). The modular system integrates both nucleic acid extraction and downstream real-time RT-PCR (rRT-PCR). The analytical sensitivity of this assay was determined using serially diluted culture grown FMDV, and the performance of the assay was evaluated using a selected range of FMDV positive and negative clinical samples of bovine, porcine and ovine origin. The robustness of the assay was evaluated in an international inter-laboratory proficiency test and by deployment into an African laboratory. It was demonstrated that the system is easy to use and can detect FMDV with high sensitivity and specificity, roughly on par with standard laboratory methods. This cartridge-based automated real-time RT-PCR system for the detection of FMDV represents a reliable and easy to use diagnostic tool for the early and rapid disease detection of acutely infected animals even in remote areas. This type of system could be easily deployed for routine surveillance within endemic regions such as Africa or could alternatively be used in the developed world. © 2017 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.
Mezzano, Diego; Quiroga, Teresa; Pereira, Jaime
2009-03-01
The major advances from research on platelet molecular and cell biology, physiology, and pathophysiology over the past decades have not been adequately translated to clinical laboratory diagnosis. Hereditary platelet function disorders (PFDs) are at least as prevalent in the general population as von Willebrand disease (VWD) although PFDs tend not be as well recognized or evaluated. Clinical mucous and skin bleeding in patients with PFDs is prototypic of primary hemostasis disorders, and the bleeding pattern is not distinguishable from that of other primary hemostasis disorders such as VWD. However, different treatment needs, between these discrete disorders, make a precise diagnosis mandatory. Currently, clinicians receive reliable laboratory reports when testing patients with severe PFDs, such as Glanzmann thrombasthenia and Bernard-Soulier syndrome, due to the distinctive laboratory defects that these disorders present, together with the availability of differential diagnostic tests. This is not the case for the majority of PFDs generically classified as "platelet secretion disorders," which are a heterogeneous group of "mild bleeding disorders," for which there are not universally accepted diagnostic criteria. An important reason for robust diagnostic tests is the high proportion (more than 50% in some reports) of patients with unequivocal bleeding who have no precise diagnosis established after a complete laboratory workup. It is paradoxical that the current "gold standard" test for PFD diagnosis, light transmission aggregometry (LTA), has not been standardized after more than four decades of worldwide clinical use. This review describes current diagnostic assays for PFD in a clinical hemostasis laboratory, relating these with current knowledge on platelet function and pathophysiology. Special emphasis will be given to LTA and platelet secretion tests, as well as to the reasons why sensitive tests are needed to explore the lesser known participation of platelets in blood clotting and fibrinolytic processes.
Hunsperger, Elizabeth A.; Yoksan, Sutee; Buchy, Philippe; Nguyen, Vinh Chau; Sekaran, Shamala Devi; Enria, Delia A.; Vazquez, Susana; Cartozian, Elizabeth; Pelegrino, Jose L.; Artsob, Harvey; Guzman, Maria G.; Olliaro, Piero; Zwang, Julien; Guillerm, Martine; Kliks, Susie; Halstead, Scott; Peeling, Rosanna W.; Margolis, Harold S.
2014-01-01
Commercially available diagnostic test kits for detection of dengue virus (DENV) non-structural protein 1 (NS1) and anti-DENV IgM were evaluated for their sensitivity and specificity and other performance characteristics by a diagnostic laboratory network developed by World Health Organization (WHO), the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR) and the Pediatric Dengue Vaccine Initiative (PDVI). Each network laboratory contributed characterized serum specimens for the panels used in the evaluation. Microplate enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT formats) were represented by the kits. Each ELISA was evaluated by 2 laboratories and RDTs were evaluated by at least 3 laboratories. The reference tests for IgM anti-DENV were laboratory developed assays produced by the Armed Forces Research Institute for Medical Science (AFRIMS) and the Centers for Disease Control and Prevention (CDC), and the NS1 reference test was reverse transcriptase polymerase chain reaction (RT-PCR). Results were analyzed to determine sensitivity, specificity, inter-laboratory and inter-reader agreement, lot-to-lot variation and ease-of-use. NS1 ELISA sensitivity was 60–75% and specificity 71–80%; NS1 RDT sensitivity was 38–71% and specificity 76–80%; the IgM anti-DENV RDTs sensitivity was 30–96%, with a specificity of 86–92%, and IgM anti-DENV ELISA sensitivity was 96–98% and specificity 78–91%. NS1 tests were generally more sensitive in specimens from the acute phase of dengue and in primary DENV infection, whereas IgM anti-DENV tests were less sensitive in secondary DENV infections. The reproducibility of the NS1 RDTs ranged from 92-99% and the IgM anti-DENV RDTs from 88–94%. PMID:25330157
Ciocchini, Andrés E.; Rey Serantes, Diego A.; Melli, Luciano J.; Iwashkiw, Jeremy A.; Deodato, Bettina; Wallach, Jorge; Feldman, Mario F.; Ugalde, Juan E.; Comerci, Diego J.
2013-01-01
Brucellosis is a highly contagious zoonosis and still a major human health problem in endemic areas of the world. Although several diagnostic tools are available, most of them are difficult to implement especially in developing countries where complex health facilities are limited. Taking advantage of the identical structure and composition of the Brucella spp. and Yersinia enterocolitica O:9 O-polysaccharide, we explored the application of a recombinant Y. enterocolitica O:9-polysaccharide-protein conjugate (OAg-AcrA) as a novel antigen for diagnosis of human brucellosis. We have developed and validated an indirect immunoassay using OAg-AcrA coupled to magnetic beads. OAg-AcrA was produced and purified with high yields in Y. enterocolitica O:9 cells co-expressing the oligosaccharyltransferase PglB and the protein acceptor AcrA of Campylobacter jejuni without the need for culturing Brucella. Expression of PglB and AcrA in Y. enterocolitica resulted in the transfer of the host O-polysaccharide from its lipid carrier to AcrA. To validate the assay and determine the cutoff values, a receiver-operating characteristic analysis was performed using a panel of characterized serum samples obtained from healthy individuals and patients of different clinical groups. Our results indicate that, using this assay, it is possible to detect infection caused by the three main human brucellosis agents (B. abortus, B. melitensis and B. suis) and select different cutoff points to adjust sensitivity and specificity levels as needed. A cutoff value of 13.20% gave a sensitivity of 100% and a specificity of 98.57%, and a cutoff value of 16.15% resulted in a test sensitivity and specificity of 93.48% and 100%, respectively. The high diagnostic accuracy, low cost, reduced assay time and simplicity of this new glycoconjugate-magnetic beads assay makes it an attractive diagnostic tool for using not only in clinics and brucellosis reference laboratories but also in locations with limited laboratory infrastructure and/or minimally trained community health workers. PMID:23459192
Katti, Kattesh V.; Berning, Douglas E.; Volkert, Wynn A.; Ketring, Alan R.
1998-01-01
A complex and method for making same for use as a diagnostic or therapeutic pharmaceutical includes a ligand comprising at least one hydroxyalkyl phosphine donor group bound to a gold atom to form a gold-ligand complex that is stable in aqueous solutions containing oxygen, serum and other body fluids.
Katti, K.V.; Berning, D.E.; Volkert, W.A.; Ketring, A.R.
1998-12-01
A complex and method for making a diagnostic or therapeutic pharmaceutical includes a ligand comprising at least one hydroxyalkyl phosphine donor group bound to a gold atom to form a gold-ligand complex that is stable in aqueous solutions containing oxygen, serum and other body fluids. 20 figs.
Kimmel, April D.; Losina, Elena; Freedberg, Kenneth A.; Goldie, Sue J.
2006-01-01
We conducted a systematic review on the performance of diagnostic tests for clinical and laboratory monitoring of HIV-infected adults in developing countries. Diagnostic test information collected from computerized databases, bibliographies and the Internet were categorized as clinical (non-laboratory patient information), immunologic (information from immunologic laboratory tests), or virologic (information from virologic laboratory tests). Of the 51 studies selected for the review 28 assessed immunologic tests, 12 virologic tests and seven clinical and immunologic tests. Methods of performance evaluation were primarily sensitivity and specificity for the clinical category and correlation coefficients for immunologic and virologic categories. In the clinical category, the majority of test performance measures was reported as >70% sensitive and >65% specific. In the immunologic category, correlation coefficients ranged from r=0.54 to r=0.99 for different CD4 count enumeration techniques, while correlation for CD4 and total lymphocyte counts was between r=0.23 and r=0.74. In the virologic category, correlation coefficients for different human immunodeficiency virus (HIV) ribonucleic acid (RNA) quantification techniques ranged from r=0.54 to r=0.90. Future research requires consensus on designing studies, and collecting and reporting data useful for decision-makers. We recommend classifying information into clinically relevant categories, using a consistent definition of disease across studies and providing measures of both association and accuracy. PMID:16878233
Korošec, Peter; Šilar, Mira; Eržen, Renato; Čelesnik, Nina; Bajrović, Nissera; Zidarn, Mihaela; Košnik, Mitja
2013-01-01
Previous reports suggest the usefulness of basophil activation testing (BAT) in Hymenoptera-allergic patients with negative venom-specific IgE antibodies. We sought to evaluate the diagnostic utility of this testing in a routine clinical laboratory setting. Twenty-one patients with anaphylactic reactions to Hymenoptera sting (median grade III) and negative venom-specific IgE were routinely and prospectively tested with BAT. We were able to diagnose 81% (17 of 21) of patients with BAT and 57% (12 of 21) with intradermal skin testing. Three wasp venom-allergic patients showed IgE positivity to rVes v 5. Four patients (19%) were negative for all tests. In the case of double-positive BAT, the culprit insect correlated with the venom that induced a significantly higher basophil response. BAT allows the identification of severe Hymenoptera-allergic patients with negative specific IgE and skin tests. The routine use of this cellular test should facilitate prescription of venom immunotherapy in complex cases with inconclusive diagnostic results. Copyright © 2013 S. Karger AG, Basel.
[Mobile stroke unit for prehospital stroke treatment].
Walter, S; Grunwald, I Q; Fassbender, K
2016-01-01
The management of acute stroke patients suffers from several major problems in the daily clinical routine. In order to achieve optimal treatment a complex diagnostic work-up and rapid initiation of therapy are necessary; however, most patients arrive at hospital too late for any type of acute stroke treatment, although all forms of treatment are highly time-dependent according to the generally accepted "time is brain" concept. Recently, two randomized clinical trials demonstrated the feasibility of prehospital stroke diagnostic work-up and treatment. This was accomplished by use of a specialized ambulance, equipped with computed tomography for multimodal imaging and a point-of-care laboratory system. In both trials the results demonstrated a clear superiority of the prehospital treatment group with a significant reduction of treatment times, significantly increased number of patients treated within the first 60 min after symptom onset and an optimized triage to the correct target hospital. Currently, mobile stroke units are in operation in various countries and should lead to an improvement in stroke treatment; nevertheless, intensive research is still needed to analyze the best framework settings for prehospital stroke management.
Wilke, Russell A; Berg, Richard L; Peissig, Peggy; Kitchner, Terrie; Sijercic, Bozana; McCarty, Catherine A; McCarty, Daniel J
2007-03-01
Diabetes mellitus is a rapidly increasing and costly public health problem. Large studies are needed to understand the complex gene-environment interactions that lead to diabetes and its complications. The Marshfield Clinic Personalized Medicine Research Project (PMRP) represents one of the largest population-based DNA biobanks in the United States. As part of an effort to begin phenotyping common diseases within the PMRP, we now report on the construction of a diabetes case-finding algorithm using electronic medical record data from adult subjects aged > or =50 years living in one of the target PMRP ZIP codes. Based upon diabetic diagnostic codes alone, we observed a false positive case rate ranging from 3.0% (in subjects with the highest glycosylated hemoglobin values) to 44.4% (in subjects with the lowest glycosylated hemoglobin values). We therefore developed an improved case finding algorithm that utilizes diabetic diagnostic codes in combination with clinical laboratory data and medication history. This algorithm yielded an estimated prevalence of 24.2% for diabetes mellitus in adult subjects aged > or =50 years.
Concordance in diagnostic testing for respiratory pathogens of Bighorn Sheep
USDA-ARS?s Scientific Manuscript database
Reliable diagnostic tests are essential for disease investigation and management. This is particularly true for diseases of free-ranging wildlife where sampling is logistically difficult precluding retesting. Clinical assays for wildlife diseases frequently vary among laboratories because of lack ...
Clinical laboratory: bigger is not always better.
Plebani, Mario
2018-06-27
Laboratory services around the world are undergoing substantial consolidation and changes through mechanisms ranging from mergers, acquisitions and outsourcing, primarily based on expectations to improve efficiency, increasing volumes and reducing the cost per test. However, the relationship between volume and costs is not linear and numerous variables influence the end cost per test. In particular, the relationship between volumes and costs does not span the entire platter of clinical laboratories: high costs are associated with low volumes up to a threshold of 1 million test per year. Over this threshold, there is no linear association between volumes and costs, as laboratory organization rather than test volume more significantly affects the final costs. Currently, data on laboratory errors and associated diagnostic errors and risk for patient harm emphasize the need for a paradigmatic shift: from a focus on volumes and efficiency to a patient-centered vision restoring the nature of laboratory services as an integral part of the diagnostic and therapy process. Process and outcome quality indicators are effective tools to measure and improve laboratory services, by stimulating a competition based on intra- and extra-analytical performance specifications, intermediate outcomes and customer satisfaction. Rather than competing with economic value, clinical laboratories should adopt a strategy based on a set of harmonized quality indicators and performance specifications, active laboratory stewardship, and improved patient safety.
Molecular diagnostic methods for invasive fungal disease: the horizon draws nearer?
Halliday, C L; Kidd, S E; Sorrell, T C; Chen, S C-A
2015-04-01
Rapid, accurate diagnostic laboratory tests are needed to improve clinical outcomes of invasive fungal disease (IFD). Traditional direct microscopy, culture and histological techniques constitute the 'gold standard' against which newer tests are judged. Molecular diagnostic methods, whether broad-range or fungal-specific, have great potential to enhance sensitivity and speed of IFD diagnosis, but have varying specificities. The use of PCR-based assays, DNA sequencing, and other molecular methods including those incorporating proteomic approaches such as matrix-assisted laser desorption ionisation-time of flight mass spectroscopy (MALDI-TOF MS) have shown promising results. These are used mainly to complement conventional methods since they require standardisation before widespread implementation can be recommended. None are incorporated into diagnostic criteria for defining IFD. Commercial assays may assist standardisation. This review provides an update of molecular-based diagnostic approaches applicable to biological specimens and fungal cultures in microbiology laboratories. We focus on the most common pathogens, Candida and Aspergillus, and the mucormycetes. The position of molecular-based approaches in the detection of azole and echinocandin antifungal resistance is also discussed.
Talbot-Lau x-ray interferometry for high energy density plasma diagnostic.
Stutman, D; Finkenthal, M
2011-11-01
High resolution density diagnostics are difficult in high energy density laboratory plasmas (HEDLP) experiments due to the scarcity of probes that can penetrate above solid density plasmas. Hard x-rays are one possible probe for such dense plasmas. We study the possibility of applying an x-ray method recently developed for medical imaging, differential phase-contrast with Talbot-Lau interferometers, for the diagnostic of electron density and small-scale hydrodynamic instabilities in HEDLP experiments. The Talbot method uses micro-periodic gratings to measure the refraction and ultra-small angle scatter of x-rays through an object and is attractive for HEDLP diagnostic due to its capability to work with incoherent and polychromatic x-ray sources such as the laser driven backlighters used for HEDLP radiography. Our paper studies the potential of the Talbot method for HEDLP diagnostic, its adaptation to the HEDLP environment, and its extension of high x-ray energy using micro-periodic mirrors. The analysis is illustrated with experimental results obtained using a laboratory Talbot interferometer. © 2011 American Institute of Physics
[The National Reference Centres and Reference Laboratories. Importance and tasks].
Laude, G; Ammon, A
2005-09-01
Since 1995, the German Federal Ministry for Health and Social Security funds National Reference Centres (NRC) for the laboratory surveillance of important pathogens and syndromes. Which pathogens or syndromes are selected to be covered by a NRC depends on their epidemiological relevance, the special diagnostic tools, problems with antimicrobial resistance and necessary infection control measures. Currently, there are 15 NRC, which are appointed for a period of 3 years (currently from January 2005 through December 2007). Towards the end of their appointment all NRC are evaluated by a group of specialists. The assessment of their achievements is guided by a catalogue of tasks for the NRC. In addition to the NRC, a total of 50 laboratories are appointed which provide specialist expertise for additional pathogens in order to have a broad range of pathogens for which specialist laboratories are available. Their predominant task is to give advice and support for special diagnostic problems. Both NRC and the specialist laboratories are important parts of the network for infectious disease epidemiology.
42 CFR 493.25 - Laboratories performing tests of high complexity.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 5 2011-10-01 2011-10-01 false Laboratories performing tests of high complexity. 493.25 Section 493.25 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND....25 Laboratories performing tests of high complexity. (a) A laboratory must obtain a certificate for...
42 CFR 493.25 - Laboratories performing tests of high complexity.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 5 2010-10-01 2010-10-01 false Laboratories performing tests of high complexity. 493.25 Section 493.25 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND....25 Laboratories performing tests of high complexity. (a) A laboratory must obtain a certificate for...
Ebola Laboratory Response at the Eternal Love Winning Africa Campus, Monrovia, Liberia, 2014–2015
de Wit, Emmie; Rosenke, Kyle; Fischer, Robert J.; Marzi, Andrea; Prescott, Joseph; Bushmaker, Trenton; van Doremalen, Neeltje; Emery, Shannon L.; Falzarano, Darryl; Feldmann, Friederike; Groseth, Allison; Hoenen, Thomas; Juma, Bonventure; McNally, Kristin L.; Ochieng, Melvin; Omballa, Victor; Onyango, Clayton O.; Owuor, Collins; Rowe, Thomas; Safronetz, David; Self, Joshua; Williamson, Brandi N.; Zemtsova, Galina; Grolla, Allen; Kobinger, Gary; Rayfield, Mark; Ströher, Ute; Strong, James E.; Best, Sonja M.; Ebihara, Hideki; Zoon, Kathryn C.; Nichol, Stuart T.; Nyenswah, Tolbert G.; Bolay, Fatorma K.; Massaquoi, Moses; Feldmann, Heinz; Fields, Barry
2016-01-01
West Africa experienced the first epidemic of Ebola virus infection, with by far the greatest number of cases in Guinea, Sierra Leone, and Liberia. The unprecedented epidemic triggered an unparalleled response, including the deployment of multiple Ebola treatment units and mobile/field diagnostic laboratories. The National Institute of Allergy and Infectious Diseases and the Centers for Disease Control and Prevention deployed a joint laboratory to Monrovia, Liberia, in August 2014 to support the newly founded Ebola treatment unit at the Eternal Love Winning Africa (ELWA) campus. The laboratory operated initially out of a tent structure but quickly moved into a fixed-wall building owing to severe weather conditions, the need for increased security, and the high sample volume. Until May 2015, when the laboratory closed, the site handled close to 6000 clinical specimens for Ebola virus diagnosis and supported the medical staff in case patient management. Laboratory operation and safety, as well as Ebola virus diagnostic assays, are described and discussed; in addition, lessons learned for future deployments are reviewed. PMID:27333914
Wanja, Elizabeth; Achilla, Rachel; Obare, Peter; Adeny, Rose; Moseti, Caroline; Otieno, Victor; Morang'a, Collins; Murigi, Ephantus; Nyamuni, John; Monthei, Derek R; Ogutu, Bernhards; Buff, Ann M
2017-05-25
One objective of the Kenya National Malaria Strategy 2009-2017 is scaling access to prompt diagnosis and effective treatment. In 2013, a quality assurance (QA) pilot was implemented to improve accuracy of malaria diagnostics at selected health facilities in low-transmission counties of Kenya. Trends in malaria diagnostic and QA indicator performance during the pilot are described. From June to December 2013, 28 QA officers provided on-the-job training and mentoring for malaria microscopy, malaria rapid diagnostic tests and laboratory QA/quality control (QC) practices over four 1-day visits at 83 health facilities. QA officers observed and recorded laboratory conditions and practices and cross-checked blood slides for malaria parasite presence, and a portion of cross-checked slides were confirmed by reference laboratories. Eighty (96%) facilities completed the pilot. Among 315 personnel at pilot initiation, 13% (n = 40) reported malaria diagnostics training within the previous 12 months. Slide positivity ranged from 3 to 7%. Compared to the reference laboratory, microscopy sensitivity ranged from 53 to 96% and positive predictive value from 39 to 53% for facility staff and from 60 to 96% and 52 to 80%, respectively, for QA officers. Compared to reference, specificity ranged from 88 to 98% and negative predictive value from 98 to 99% for health-facility personnel and from 93 to 99% and 99%, respectively, for QA officers. The kappa value ranged from 0.48-0.66 for facility staff and 0.57-0.84 for QA officers compared to reference. The only significant test performance improvement observed for facility staff was for specificity from 88% (95% CI 85-90%) to 98% (95% CI 97-99%). QA/QC practices, including use of positive-control slides, internal and external slide cross-checking and recording of QA/QC activities, all increased significantly across the pilot (p < 0.001). Reference material availability also increased significantly; availability of six microscopy job aids and seven microscopy standard operating procedures increased by a mean of 32 percentage points (p < 0.001) and 38 percentage points (p < 0.001), respectively. Significant gains were observed in malaria QA/QC practices over the pilot. However, these advances did not translate into improved accuracy of malaria diagnostic performance perhaps because of the limited duration of the QA pilot implementation.
NASA Astrophysics Data System (ADS)
Smolyanskaya, O. A.; Kravtsenyuk, O. V.; Panchenko, A. V.; Odlyanitskiy, E. L.; Guillet, J. P.; Cherkasova, O. P.; Khodzitsky, M. K.
2017-12-01
In the course of in vitro studies of blood of laboratory animals with progressing Ehrlich carcinoma, we have revealed the change of the blood plasma optical properties in the THz range, which can be used for developing the express diagnostics of the presence of oncological diseases. An applied software package is elaborated that allows the phantoms of biological samples having a complex structure to be numerically simulated and the parameters of the electromagnetic wave reflected from these samples in the THz frequency range to be calculated. Presented at the Fundamentals of Laser Micro- and Nanotechnologies (FLAMN-16) International Symposium (Pushkin, Leningrad oblast, 27 June to 1 July 2016).
Teaching pediatric laboratory medicine to pathology residents.
Pysher, Theodore J; Bach, Philip R; Geaghan, Sharon M; Hamilton, Marilyn S; Laposata, Michael; Lockitch, Gillian; Brugnara, Carlo; Coffin, Cheryl M; Pasquali, Marzia; Rinaldo, Piero; Roberts, William L; Rutledge, Joe C; Ashwood, Edward R; Blaylock, Robert C; Campos, Joseph M; Goldsmith, Barbara; Jones, Patricia M; Lim, Megan; Meikle, A Wayne; Perkins, Sherrie L; Perry, Deborah A; Petti, Cathy A; Rogers, Beverly B; Steele, Paul E; Weiss, Ronald L; Woods, Gail
2006-07-01
Laboratory data are essential to the medical care of fetuses, infants, children, and adolescents. However, the performance and interpretation of laboratory tests on specimens from these patients, which may constitute a significant component of the workload in general hospitals and integrated health care systems as well as specialized perinatal or pediatric centers, present unique challenges to the clinical pathologist and the laboratory. Therefore, pathology residents should receive training in pediatric laboratory medicine. Children's Health Improvement through Laboratory Diagnostics, a group of pathologists and laboratory scientists with interest and expertise in pediatric laboratory medicine, convened a task force to develop a list of curriculum topics, key resources, and training experiences in pediatric laboratory medicine for trainees in anatomic and clinical pathology or straight clinical pathology residency programs and in pediatric pathology fellowship programs. Based on the experiences of 11 training programs, we have compiled a comprehensive list of pediatric topics in the areas of clinical chemistry, endocrinology, hematology, urinalysis, coagulation medicine, transfusion medicine, immunology, microbiology and virology, biochemical genetics, cytogenetics and molecular diagnostics, point of care testing, and laboratory management. This report also includes recommendations for training experiences and a list of key texts and other resources in pediatric laboratory medicine. Clinical pathologists should be trained to meet the laboratory medicine needs of pediatric patients and to assist the clinicians caring for these patients with the selection and interpretation of laboratory studies. This review helps program directors tailor their curricula to more effectively provide this training.
Clinical Laboratory Values as Early Indicators of Ebola Virus Infection in Nonhuman Primates.
Reisler, Ronald B; Yu, Chenggang; Donofrio, Michael J; Warren, Travis K; Wells, Jay B; Stuthman, Kelly S; Garza, Nicole L; Vantongeren, Sean A; Donnelly, Ginger C; Kane, Christopher D; Kortepeter, Mark G; Bavari, Sina; Cardile, Anthony P
2017-08-01
The Ebola virus (EBOV) outbreak in West Africa during 2013-2016 demonstrated the need to improve Ebola virus disease (EVD) diagnostics and standards of care. This retrospective study compared laboratory values and clinical features of 3 nonhuman primate models of lethal EVD to assess associations with improved survival time. In addition, the study identified laboratory values useful as predictors of survival, surrogates for EBOV viral loads, and triggers for initiation of therapeutic interventions in these nonhuman primate models. Furthermore, the data support that, in nonhuman primates, the Makona strain of EBOV may be less virulent than the Kikwit strain of EBOV. The applicability of these findings as potential diagnostic and management tools for EVD in humans warrants further investigation.
The clinical and laboratory correlates of an increased urinary 5-hydroxyindoleacetic acid.
Tormey, W. P.; FitzGerald, R. J.
1995-01-01
Over a five-and-a-half-year period, there were 298 laboratory requests for urinary 5-hydroxyindoleacetic acid (5-HIAA). The clinical and laboratory associations of the 24 patients in which there were 43 urinary 5-HIAA 24-h collection results greater than the laboratory upper reference limit are detailed. Four were confirmed carcinoid tumours and two were phaeochromocytomas. Flushing was a prominent symptom in 46% and diarrhoea or altered bowel habit in 37%. Associated with the raised urinary 5-HIAA values were increased levels of 4-hydroxy-3-methoxymandelic acid and homovanillic acid in 14.3% and 21%, respectively, of those collections where the metabolites were requested. Diagnostic imaging was performed in 57%. While the specificity was 88%, 5-HIAA is relatively insensitive in the diagnosis of carcinoid tumours and a more widespread use of diagnostic imaging including isotope scanning with labelled metaiodo-benzylguanidine, vasoactive intestinal peptide and octreotide is suggested. PMID:7479466
Moore, Andrew; Nelson, Christina; Molins, Claudia; Mead, Paul; Schriefer, Martin
2016-07-01
In the United States, Lyme disease is caused by Borrelia burgdorferi and transmitted to humans by blacklegged ticks. Patients with an erythema migrans lesion and epidemiologic risk can receive a diagnosis without laboratory testing. For all other patients, laboratory testing is necessary to confirm the diagnosis, but proper interpretation depends on symptoms and timing of illness. The recommended laboratory test in the United States is 2-tiered serologic analysis consisting of an enzyme-linked immunoassay or immunofluorescence assay, followed by reflexive immunoblotting. Sensitivity of 2-tiered testing is low (30%-40%) during early infection while the antibody response is developing (window period). For disseminated Lyme disease, sensitivity is 70%-100%. Specificity is high (>95%) during all stages of disease. Use of other diagnostic tests for Lyme disease is limited. We review the rationale behind current US testing guidelines, appropriate use and interpretation of tests, and recent developments in Lyme disease diagnostics.
Collection, transport and general processing of clinical specimens in Microbiology laboratory.
Sánchez-Romero, M Isabel; García-Lechuz Moya, Juan Manuel; González López, Juan José; Orta Mira, Nieves
2018-02-06
The interpretation and the accuracy of the microbiological results still depend to a great extent on the quality of the samples and their processing within the Microbiology laboratory. The type of specimen, the appropriate time to obtain the sample, the way of sampling, the storage and transport are critical points in the diagnostic process. The availability of new laboratory techniques for unusual pathogens, makes necessary the review and update of all the steps involved in the processing of the samples. Nowadays, the laboratory automation and the availability of rapid techniques allow the precision and turn-around time necessary to help the clinicians in the decision making. In order to be efficient, it is very important to obtain clinical information to use the best diagnostic tools. Copyright © 2018 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Economic challenges associated with tuberculosis diagnostic development
Hanrahan, Colleen F.; Shah, Maunank
2015-01-01
Tuberculosis remains a global health crisis in part due to underdiagnosis. Technological innovations are needed to improve diagnostic test accuracy and reduce the reliance on expensive laboratory infrastructure. However, there are significant economic challenges impeding the development and implementation of new diagnostics. The aim of this piece is to examine the current state of TB diagnostics, outline the unmet needs for new tests, and detail the economic challenges associated with development of new tests from the perspective of developers, policy makers and implementers. PMID:24766367
Economic challenges associated with tuberculosis diagnostic development.
Hanrahan, Colleen F; Shah, Maunank
2014-08-01
Tuberculosis remains a global health crisis in part due to underdiagnosis. Technological innovations are needed to improve diagnostic test accuracy and reduce the reliance on expensive laboratory infrastructure. However, there are significant economic challenges impeding the development and implementation of new diagnostics. The aim of this piece is to examine the current state of TB diagnostics, outline the unmet needs for new tests, and detail the economic challenges associated with development of new tests from the perspective of developers, policy makers and implementers.
The Spallation Neutron Source accelerator system design
NASA Astrophysics Data System (ADS)
Henderson, S.; Abraham, W.; Aleksandrov, A.; Allen, C.; Alonso, J.; Anderson, D.; Arenius, D.; Arthur, T.; Assadi, S.; Ayers, J.; Bach, P.; Badea, V.; Battle, R.; Beebe-Wang, J.; Bergmann, B.; Bernardin, J.; Bhatia, T.; Billen, J.; Birke, T.; Bjorklund, E.; Blaskiewicz, M.; Blind, B.; Blokland, W.; Bookwalter, V.; Borovina, D.; Bowling, S.; Bradley, J.; Brantley, C.; Brennan, J.; Brodowski, J.; Brown, S.; Brown, R.; Bruce, D.; Bultman, N.; Cameron, P.; Campisi, I.; Casagrande, F.; Catalan-Lasheras, N.; Champion, M.; Champion, M.; Chen, Z.; Cheng, D.; Cho, Y.; Christensen, K.; Chu, C.; Cleaves, J.; Connolly, R.; Cote, T.; Cousineau, S.; Crandall, K.; Creel, J.; Crofford, M.; Cull, P.; Cutler, R.; Dabney, R.; Dalesio, L.; Daly, E.; Damm, R.; Danilov, V.; Davino, D.; Davis, K.; Dawson, C.; Day, L.; Deibele, C.; Delayen, J.; DeLong, J.; Demello, A.; DeVan, W.; Digennaro, R.; Dixon, K.; Dodson, G.; Doleans, M.; Doolittle, L.; Doss, J.; Drury, M.; Elliot, T.; Ellis, S.; Error, J.; Fazekas, J.; Fedotov, A.; Feng, P.; Fischer, J.; Fox, W.; Fuja, R.; Funk, W.; Galambos, J.; Ganni, V.; Garnett, R.; Geng, X.; Gentzlinger, R.; Giannella, M.; Gibson, P.; Gillis, R.; Gioia, J.; Gordon, J.; Gough, R.; Greer, J.; Gregory, W.; Gribble, R.; Grice, W.; Gurd, D.; Gurd, P.; Guthrie, A.; Hahn, H.; Hardek, T.; Hardekopf, R.; Harrison, J.; Hatfield, D.; He, P.; Hechler, M.; Heistermann, F.; Helus, S.; Hiatt, T.; Hicks, S.; Hill, J.; Hill, J.; Hoff, L.; Hoff, M.; Hogan, J.; Holding, M.; Holik, P.; Holmes, J.; Holtkamp, N.; Hovater, C.; Howell, M.; Hseuh, H.; Huhn, A.; Hunter, T.; Ilg, T.; Jackson, J.; Jain, A.; Jason, A.; Jeon, D.; Johnson, G.; Jones, A.; Joseph, S.; Justice, A.; Kang, Y.; Kasemir, K.; Keller, R.; Kersevan, R.; Kerstiens, D.; Kesselman, M.; Kim, S.; Kneisel, P.; Kravchuk, L.; Kuneli, T.; Kurennoy, S.; Kustom, R.; Kwon, S.; Ladd, P.; Lambiase, R.; Lee, Y. Y.; Leitner, M.; Leung, K.-N.; Lewis, S.; Liaw, C.; Lionberger, C.; Lo, C. C.; Long, C.; Ludewig, H.; Ludvig, J.; Luft, P.; Lynch, M.; Ma, H.; MacGill, R.; Macha, K.; Madre, B.; Mahler, G.; Mahoney, K.; Maines, J.; Mammosser, J.; Mann, T.; Marneris, I.; Marroquin, P.; Martineau, R.; Matsumoto, K.; McCarthy, M.; McChesney, C.; McGahern, W.; McGehee, P.; Meng, W.; Merz, B.; Meyer, R.; Meyer, R.; Miller, B.; Mitchell, R.; Mize, J.; Monroy, M.; Munro, J.; Murdoch, G.; Musson, J.; Nath, S.; Nelson, R.; Nelson, R.; O`Hara, J.; Olsen, D.; Oren, W.; Oshatz, D.; Owens, T.; Pai, C.; Papaphilippou, I.; Patterson, N.; Patterson, J.; Pearson, C.; Pelaia, T.; Pieck, M.; Piller, C.; Plawski, T.; Plum, M.; Pogge, J.; Power, J.; Powers, T.; Preble, J.; Prokop, M.; Pruyn, J.; Purcell, D.; Rank, J.; Raparia, D.; Ratti, A.; Reass, W.; Reece, K.; Rees, D.; Regan, A.; Regis, M.; Reijonen, J.; Rej, D.; Richards, D.; Richied, D.; Rode, C.; Rodriguez, W.; Rodriguez, M.; Rohlev, A.; Rose, C.; Roseberry, T.; Rowton, L.; Roybal, W.; Rust, K.; Salazer, G.; Sandberg, J.; Saunders, J.; Schenkel, T.; Schneider, W.; Schrage, D.; Schubert, J.; Severino, F.; Shafer, R.; Shea, T.; Shishlo, A.; Shoaee, H.; Sibley, C.; Sims, J.; Smee, S.; Smith, J.; Smith, K.; Spitz, R.; Staples, J.; Stein, P.; Stettler, M.; Stirbet, M.; Stockli, M.; Stone, W.; Stout, D.; Stovall, J.; Strelo, W.; Strong, H.; Sundelin, R.; Syversrud, D.; Szajbler, M.; Takeda, H.; Tallerico, P.; Tang, J.; Tanke, E.; Tepikian, S.; Thomae, R.; Thompson, D.; Thomson, D.; Thuot, M.; Treml, C.; Tsoupas, N.; Tuozzolo, J.; Tuzel, W.; Vassioutchenko, A.; Virostek, S.; Wallig, J.; Wanderer, P.; Wang, Y.; Wang, J. G.; Wangler, T.; Warren, D.; Wei, J.; Weiss, D.; Welton, R.; Weng, J.; Weng, W.-T.; Wezensky, M.; White, M.; Whitlatch, T.; Williams, D.; Williams, E.; Wilson, K.; Wiseman, M.; Wood, R.; Wright, P.; Wu, A.; Ybarrolaza, N.; Young, K.; Young, L.; Yourd, R.; Zachoszcz, A.; Zaltsman, A.; Zhang, S.; Zhang, W.; Zhang, Y.; Zhukov, A.
2014-11-01
The Spallation Neutron Source (SNS) was designed and constructed by a collaboration of six U.S. Department of Energy national laboratories. The SNS accelerator system consists of a 1 GeV linear accelerator and an accumulator ring providing 1.4 MW of proton beam power in microsecond-long beam pulses to a liquid mercury target for neutron production. The accelerator complex consists of a front-end negative hydrogen-ion injector system, an 87 MeV drift tube linear accelerator, a 186 MeV side-coupled linear accelerator, a 1 GeV superconducting linear accelerator, a 248-m circumference accumulator ring and associated beam transport lines. The accelerator complex is supported by ~100 high-power RF power systems, a 2 K cryogenic plant, ~400 DC and pulsed power supply systems, ~400 beam diagnostic devices and a distributed control system handling ~100,000 I/O signals. The beam dynamics design of the SNS accelerator is presented, as is the engineering design of the major accelerator subsystems.
Culka, Adam; Baštová, Markéta; Bašta, Petr; Kuntoš, Jaroslav
2016-01-01
A miniature lightweight portable Raman spectrometer and a palm-sized device allow for fast and unambiguous detection of common gemstones mounted in complex jewels. Here, complex religious artefacts and the Ring Monstrance from the Loreto treasury (Prague, Czech Republic; eighteenth century) were investigated. These discriminations are based on the very good correspondence of the wavenumbers of the strongest Raman bands of the minerals. Very short laser illumination times and efficient collection of scattered light were sufficient to obtain strong diagnostic Raman signals. The following minerals were documented: quartz and its varieties, beryl varieties (emerald), corundum varieties (sapphire), garnets (almandine, grossular), diamond as well as aragonite in pearls. Miniature Raman spectrometers can be recommended for common gemmological work as well as for mineralogical investigations of jewels and cultural heritage objects whenever the antiquities cannot be transported to a laboratory. This article is part of the themed issue ‘Raman spectroscopy in art and archaeology’. PMID:27799426
Jehlička, Jan; Culka, Adam; Baštová, Markéta; Bašta, Petr; Kuntoš, Jaroslav
2016-12-13
A miniature lightweight portable Raman spectrometer and a palm-sized device allow for fast and unambiguous detection of common gemstones mounted in complex jewels. Here, complex religious artefacts and the Ring Monstrance from the Loreto treasury (Prague, Czech Republic; eighteenth century) were investigated. These discriminations are based on the very good correspondence of the wavenumbers of the strongest Raman bands of the minerals. Very short laser illumination times and efficient collection of scattered light were sufficient to obtain strong diagnostic Raman signals. The following minerals were documented: quartz and its varieties, beryl varieties (emerald), corundum varieties (sapphire), garnets (almandine, grossular), diamond as well as aragonite in pearls. Miniature Raman spectrometers can be recommended for common gemmological work as well as for mineralogical investigations of jewels and cultural heritage objects whenever the antiquities cannot be transported to a laboratory.This article is part of the themed issue 'Raman spectroscopy in art and archaeology'. © 2016 The Author(s).
Breast Cancer Diagnostic System Final Report CRADA No. TC02098.0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rubenchik, A. M.; DaSilva, L. B.
This was a collaborative effort between Lawrence Livermore National Security, LLC (formerly The Regents of the University of California)/Lawrence Liver more National Laboratory (LLNL) and BioTelligent, Inc. together with a Russian Institution (BioFil, Ltd.), to develop a new system ( diagnostic device, operating procedures, algorithms and software) to accurately distinguish between benign and malignant breast tissue (Breast Cancer Diagnostic System, BCDS).
Tularemia without lesions in grey tree squirrels: A diagnostic challenge
USDA-ARS?s Scientific Manuscript database
Fifteen cases of Francisella tularenesis infection (tularemia) were identified in western grey (Sciurus griseus) and eastern grey (Sciurus carolinesis) squirrels submitted to the Washington Animal Disease Diagnostic Laboratory between 2008 and 2011. All of the squirrels originated in Washington stat...
Laboratory medicine: challenges and opportunities.
Bossuyt, Xavier; Verweire, Kurt; Blanckaert, Norbert
2007-10-01
Technologic innovations have substantially improved the productivity of clinical laboratories, but the services provided by clinical laboratories are increasingly becoming commoditized. We reflect on how current developments may affect the future of laboratory medicine and how to deal with these changes. We argue that to be prepared for the future, clinical laboratories should enhance efficiency and reduce costs by forming alliances and networks; consolidating, integrating, or outsourcing; and more importantly, create additional value by providing knowledge services related to in vitro diagnostics.
Sawford, Kate; Vollman, Ardene Robinson; Stephen, Craig
2012-01-01
The global public health community is facing the challenge of emerging infectious diseases. Historically, the majority of these diseases have arisen from animal populations at lower latitudes where many nations experience marked resource constraints. In order to minimize the impact of future events, surveillance of animal populations will need to enable prompt event detection and response. Many surveillance systems targeting animals rely on veterinarians to submit cases to a diagnostic laboratory or input clinical case data. Therefore understanding veterinarians’ decision-making process that guides laboratory case submission and their perceptions of infectious disease surveillance is foundational to interpreting disease patterns reported by laboratories and engaging veterinarians in surveillance initiatives. A focused ethnographic study was conducted with twelve field veterinary surgeons that participated in a mobile phone-based surveillance pilot project in Sri Lanka. Each participant agreed to an individual in-depth interview that was recorded and later transcribed to enable thematic analysis of the interview content. Results found that field veterinarians in Sri Lanka infrequently submit cases to laboratories – so infrequently that common case selection principles could not be described. Field veterinarians in Sri Lanka have a diagnostic process that operates independently of laboratories. Participants indicated a willingness to take part in surveillance initiatives, though they highlighted a need for incentives that satisfy a range of motivations that vary among field veterinarians. This study has implications for the future of animal health surveillance, including interpretation of disease patterns reported, system design and implementation, and engagement of data providers. PMID:23133542
2010-01-01
Background Abnormal results of diagnostic laboratory tests can be difficult to interpret when disease probability is very low. Although most physicians generally do not use Bayesian calculations to interpret abnormal results, their estimates of pretest disease probability and reasons for ordering diagnostic tests may - in a more implicit manner - influence test interpretation and further management. A better understanding of this influence may help to improve test interpretation and management. Therefore, the objective of this study was to examine the influence of physicians' pretest disease probability estimates, and their reasons for ordering diagnostic tests, on test result interpretation, posttest probability estimates and further management. Methods Prospective study among 87 primary care physicians in the Netherlands who each ordered laboratory tests for 25 patients. They recorded their reasons for ordering the tests (to exclude or confirm disease or to reassure patients) and their pretest disease probability estimates. Upon receiving the results they recorded how they interpreted the tests, their posttest probability estimates and further management. Logistic regression was used to analyse whether the pretest probability and the reasons for ordering tests influenced the interpretation, the posttest probability estimates and the decisions on further management. Results The physicians ordered tests for diagnostic purposes for 1253 patients; 742 patients had an abnormal result (64%). Physicians' pretest probability estimates and their reasons for ordering diagnostic tests influenced test interpretation, posttest probability estimates and further management. Abnormal results of tests ordered for reasons of reassurance were significantly more likely to be interpreted as normal (65.8%) compared to tests ordered to confirm a diagnosis or exclude a disease (27.7% and 50.9%, respectively). The odds for abnormal results to be interpreted as normal were much lower when the physician estimated a high pretest disease probability, compared to a low pretest probability estimate (OR = 0.18, 95% CI = 0.07-0.52, p < 0.001). Conclusions Interpretation and management of abnormal test results were strongly influenced by physicians' estimation of pretest disease probability and by the reason for ordering the test. By relating abnormal laboratory results to their pretest expectations, physicians may seek a balance between over- and under-reacting to laboratory test results. PMID:20158908
Houben, Paul H H; van der Weijden, Trudy; Winkens, Bjorn; Winkens, Ron A G; Grol, Richard P T M
2010-02-16
Abnormal results of diagnostic laboratory tests can be difficult to interpret when disease probability is very low. Although most physicians generally do not use Bayesian calculations to interpret abnormal results, their estimates of pretest disease probability and reasons for ordering diagnostic tests may--in a more implicit manner--influence test interpretation and further management. A better understanding of this influence may help to improve test interpretation and management. Therefore, the objective of this study was to examine the influence of physicians' pretest disease probability estimates, and their reasons for ordering diagnostic tests, on test result interpretation, posttest probability estimates and further management. Prospective study among 87 primary care physicians in the Netherlands who each ordered laboratory tests for 25 patients. They recorded their reasons for ordering the tests (to exclude or confirm disease or to reassure patients) and their pretest disease probability estimates. Upon receiving the results they recorded how they interpreted the tests, their posttest probability estimates and further management. Logistic regression was used to analyse whether the pretest probability and the reasons for ordering tests influenced the interpretation, the posttest probability estimates and the decisions on further management. The physicians ordered tests for diagnostic purposes for 1253 patients; 742 patients had an abnormal result (64%). Physicians' pretest probability estimates and their reasons for ordering diagnostic tests influenced test interpretation, posttest probability estimates and further management. Abnormal results of tests ordered for reasons of reassurance were significantly more likely to be interpreted as normal (65.8%) compared to tests ordered to confirm a diagnosis or exclude a disease (27.7% and 50.9%, respectively). The odds for abnormal results to be interpreted as normal were much lower when the physician estimated a high pretest disease probability, compared to a low pretest probability estimate (OR = 0.18, 95% CI = 0.07-0.52, p < 0.001). Interpretation and management of abnormal test results were strongly influenced by physicians' estimation of pretest disease probability and by the reason for ordering the test. By relating abnormal laboratory results to their pretest expectations, physicians may seek a balance between over- and under-reacting to laboratory test results.
Denlinger, David S; Creswell, Joseph A; Anderson, J Laine; Reese, Conor K; Bernhardt, Scott A
2016-04-15
Insecticide resistance to synthetic chemical insecticides is a worldwide concern in phlebotomine sand flies (Diptera: Psychodidae), the vectors of Leishmania spp. parasites. The CDC bottle bioassay assesses resistance by testing populations against verified diagnostic doses and diagnostic times for an insecticide, but the assay has been used limitedly with sand flies. The objective of this study was to determine diagnostic doses and diagnostic times for laboratory Lutzomyia longipalpis (Lutz & Nieva) and Phlebotomus papatasi (Scopoli) to ten insecticides, including pyrethroids, organophosphates, carbamates, and DDT, that are used worldwide to control vectors. Bioassays were conducted in 1,000-ml glass bottles each containing 10-25 sand flies from laboratory colonies of L. longipalpis or P. papatasi. Four pyrethroids, three organophosphates, two carbamates and one organochlorine, were evaluated. A series of concentrations were tested for each insecticide, and four replicates were conducted for each concentration. Diagnostic doses were determined only during the exposure bioassay for the organophosphates and carbamates. For the pyrethroids and DDT, diagnostic doses were determined for both the exposure bioassay and after a 24-hour recovery period. Both species are highly susceptible to the carbamates as their diagnostic doses are under 7.0 μg/ml. Both species are also highly susceptible to DDT during the exposure assay as their diagnostic doses are 7.5 μg/ml, yet their diagnostic doses for the 24-h recovery period are 650.0 μg/ml for Lu. longipalpis and 470.0 μg/ml for P. papatasi. Diagnostic doses and diagnostic times can now be incorporated into vector management programs that use the CDC bottle bioassay to assess insecticide resistance in field populations of Lu. longipalpis and P. papatasi. These findings provide initial starting points for determining diagnostic doses and diagnostic times for other sand fly vector species and wild populations using the CDC bottle bioassay.
[Advances of Molecular Diagnostic Techniques Application in Clinical Diagnosis.
Ying, Bin-Wu
2016-11-01
Over the past 20 years,clinical molecular diagnostic technology has made rapid development,and became the most promising field in clinical laboratory medicine.In particular,with the development of genomics,clinical molecular diagnostic methods will reveal the nature of clinical diseases in a deeper level,thus guiding the clinical diagnosis and treatments.Many molecular diagnostic projects have been routinely applied in clinical works.This paper reviews the advances on application of clinical diagnostic techniques in infectious disease,tumor and genetic disorders,including nucleic acid amplification,biochip,next-generation sequencing,and automation molecular system,and so on.
42 CFR 493.1264 - Standard: Parasitology.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Systems § 493.1264 Standard: Parasitology. (a) The laboratory must have available a reference collection... these references in the laboratory for appropriate comparison with diagnostic specimens. (b) The...
Diagnostic Laboratory and the Molecular Pathology Laboratory. Johns Hopkins Genomics is staffed with clinical molecular geneticists, bioinformaticists, statistical geneticists, clinical geneticists and molecular shape Claes, Peter et al, Nature Genetics, 2018 February GAME-ON & OncoArray: An International
Robinson, James C; Whaley, Christopher; Brown, Timothy T
2016-09-01
Prices for laboratory and other clinical services vary widely. Employers and insurers increasingly are adopting "reference pricing" policies to create incentives for patients to select lower-priced facilities. To measure the association between implementation of reference pricing and patient choice of laboratory, test prices, patient out-of-pocket spending, and insurer spending. We conducted an observational study of changes in laboratory pricing and selection by employees of a large national grocery firm (n = 30 415) before and after the firm implemented a reference pricing policy for laboratory services and compared the findings with changes over the same period for policy holders of a large national insurer that did not implement reference pricing (n = 181 831). The grocery firm established a maximum payment limit at the 60th percentile of the distribution of prices for each laboratory test in each region. Employees were provided with data on prices at all laboratories through a mobile digital platform. Patients selecting a laboratory that charged more than the payment limit were required to pay the full difference themselves. A total of 2.13 million claims were analyzed for 285 types of in vitro diagnostic tests between 2010 and 2013. Patient choice of laboratory, price paid per test, patient out-of-pocket costs, and employer spending. Compared with trends in prices paid by insurance policy holders not subject to reference pricing, and after adjusting for characteristics of tests and patients, implementation of reference pricing was associated with a 31.9% reduction (95% CI, 20.6%-41.6%) in average price paid per test by the third year of the program. In these 3 years, total spending on laboratory tests declined by $2.57 million (95% CI, $1.59-$3.35 million). Out-of-pocket costs by patients declined by $1.05 million (95% CI, $0.73-$1.37 million). Spending by the employer declined by $1.70 million (95% CI, $0.92-$2.48 million). When combined with access to price information, reference pricing was associated with patient choice of lower-cost laboratories and reductions in prices and payments by both employer and employees.
Williams, K; Sinclair, C; McEwan, R; Fleet, K; Balasegaram, S; Manuel, R
2014-07-01
Planning for the London 2012 Olympic and Paralympic Games at the Public Health Laboratory London was based on the requirement to meet potential increased demand with scalable capacity. The aim of this study was to determine the impact on demand for microbiology gastrointestinal diagnostic services during the Games period. Retrospective cross-sectional time-series data analysis was used to assess the number of gastrointestinal specimens received in the laboratory and the number of positive results. There was no increase in the number of gastrointestinal specimens received during the Games period, thus the Games had no impact on demand for microbiology gastrointestinal diagnostic services at the laboratory. There was a decrease in the number of public health specimens received for culture [incidence rate ratio = 0.34, 95% confidence interval (CI) = 0.13-0.86, P = 0.02] and a decrease in the number of culture positive community specimens (odds ratio = 0.59, 95 % CI = 0.40-0.85, P = 0.005), suggesting a decrease in gastrointestinal illness during the Games period. As previous planning assumptions were not based on actual specimen activity, the results of this study may modify the extent of additional planning for microbiological services required for mass gatherings. © 2014 The Authors.
Olszynko-Gryn, Jesse
2014-01-01
The Aschheim–Zondek reaction is generally regarded as the first reliable hormone test for pregnancy and as a major product of the ‘heroic age’ of reproductive endocrinology. Invented in Berlin in the late 1920s, by the mid 1930s a diagnostic laboratory in Edinburgh was performing thousands of tests every year for doctors around Britain. In her classic history of antenatal care, sociologist Ann Oakley claimed that the Aschheim–Zondek test launched a ‘modern era’ of obstetric knowledge, which asserted its superiority over that of pregnant women. This article reconsiders Oakley’s claim by examining how pregnancy testing worked in practice. It explains the British adoption of the test in terms less of the medicalisation of pregnancy than of clinicians’ increasing general reliance on laboratory services for differential diagnosis. Crucially, the Aschheim–Zondek reaction was a test not directly for the fetus, but for placental tissue. It was used, less as a yes-or-no test for ordinary pregnancy, than as a versatile diagnostic tool for the early detection of malignant tumours and hormonal deficiencies believed to cause miscarriage. This test was as much a product of oncology and the little-explored world of laboratory services as of reproductive medicine. PMID:24388014
Huang, Qing; Fu, Wei-Ling; You, Jian-Ping; Mao, Qing
2016-10-01
Ebola virus disease (EVD), caused by Ebola virus (EBOV), is a potent acute infectious disease with a high case-fatality rate. Etiological and serological EBOV detection methods, including techniques that involve the detection of the viral genome, virus-specific antigens and anti-virus antibodies, are standard laboratory diagnostic tests that facilitate confirmation or exclusion of EBOV infection. In addition, routine blood tests, liver and kidney function tests, electrolytes and coagulation tests and other diagnostic examinations are important for the clinical diagnosis and treatment of EVD. Because of the viral load in body fluids and secretions from EVD patients, all body fluids are highly contagious. As a result, biosafety control measures during the collection, transport and testing of clinical specimens obtained from individuals scheduled to undergo EBOV infection testing (including suspected, probable and confirmed cases) are crucial. This report has been generated following extensive work experience in the China Ebola Treatment Center (ETC) in Liberia and incorporates important information pertaining to relevant diagnostic standards, clinical significance, operational procedures, safety controls and other issues related to laboratory testing of EVD. Relevant opinions and suggestions are presented in this report to provide contextual awareness associated with the development of standards and/or guidelines related to EVD laboratory testing.
National Ignition Facility: Experimental plan
NASA Astrophysics Data System (ADS)
1994-05-01
As part of the Conceptual Design Report (CDR) for the National Ignition Facility (NIF), scientists from Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Sandia National Laboratory (SNL), the University of Rochester's Laboratory for Laser Energetics (UR/LLE), and EG&G formed an NIF Target Diagnostics Working Group. The purpose of the Target Diagnostics Working Group is to prepare conceptual designs of target diagnostics for inclusion in the facility CDR and to determine how these specifications impact the CDR. To accomplish this, a subgroup has directed its efforts at constructing an approximate experimental plan for the ignition campaign of the NIF CDR. The results of this effort are contained in this document, the Experimental Plan for achieving fusion ignition in the NIF. This group initially concentrated on the flow-down requirements of the experimental campaign leading to ignition, which will dominate the initial efforts of the NIF. It is envisaged, however, that before ignition, there will be parallel campaigns supporting weapons physics, weapons effects, and other research. This plan was developed by analyzing the sequence of activities required to finally fire the laser at the level of power and precision necessary to achieve the conditions of an ignition hohlraum target, and to then use our experience in activating and running Nova experiments to estimate the rate of completing these activities.
SODI-COLLOID (Selectable Optical Diagnostics Instrument - Colloid)
2011-10-17
ISS029-E-027431 (17 Oct. 2011) --- In the International Space Station?s Destiny laboratory, Japan Aerospace Exploration Agency astronaut Satoshi Furukawa, Expedition 29 flight engineer, activates the Microgravity Science Glovebox (MSG) in preparation for work with the Selectable Optical Diagnostics Instrument ? Colloid (SODI-COLLOID) hardware.
SODI-COLLOID (Selectable Optical Diagnostics Instrument - Colloid)
2011-10-17
ISS029-E-027435 (17 Oct. 2011) --- In the International Space Station?s Destiny laboratory, Japan Aerospace Exploration Agency astronaut Satoshi Furukawa, Expedition 29 flight engineer, activates the Microgravity Science Glovebox (MSG) in preparation for work with the Selectable Optical Diagnostics Instrument ? Colloid (SODI-COLLOID) hardware.
Michaud, Ginette Y
2005-01-01
In the field of clinical laboratory medicine, standardization is aimed at increasing the trueness and reliability of measured values. Standardization relies on the use of written standards, reference measurement procedures and reference materials. These are important tools for the design and validation of new tests, and for establishing the metrological traceability of diagnostic assays. Their use supports the translation of research technologies into new diagnostic assays and leads to more rapid advances in science and medicine, as well as improvements in the quality of patient care. The various standardization tools are described, as are the procedures by which written standards, reference procedures and reference materials are developed. Recent efforts to develop standards for use in the field of molecular diagnostics are discussed. The recognition of standardization tools by the FDA and other regulatory authorities is noted as evidence of their important role in ensuring the safety and performance of in vitro diagnostic devices.
Approximation algorithms for a genetic diagnostics problem.
Kosaraju, S R; Schäffer, A A; Biesecker, L G
1998-01-01
We define and study a combinatorial problem called WEIGHTED DIAGNOSTIC COVER (WDC) that models the use of a laboratory technique called genotyping in the diagnosis of an important class of chromosomal aberrations. An optimal solution to WDC would enable us to define a genetic assay that maximizes the diagnostic power for a specified cost of laboratory work. We develop approximation algorithms for WDC by making use of the well-known problem SET COVER for which the greedy heuristic has been extensively studied. We prove worst-case performance bounds on the greedy heuristic for WDC and for another heuristic we call directional greedy. We implemented both heuristics. We also implemented a local search heuristic that takes the solutions obtained by greedy and dir-greedy and applies swaps until they are locally optimal. We report their performance on a real data set that is representative of the options that a clinical geneticist faces for the real diagnostic problem. Many open problems related to WDC remain, both of theoretical interest and practical importance.
Advances and challenges in biosensor-based diagnosis of infectious diseases
Sin, Mandy LY; Mach, Kathleen E; Wong, Pak Kin; Liao, Joseph C
2014-01-01
Rapid diagnosis of infectious diseases and timely initiation of appropriate treatment are critical determinants that promote optimal clinical outcomes and general public health. Conventional in vitro diagnostics for infectious diseases are time-consuming and require centralized laboratories, experienced personnel and bulky equipment. Recent advances in biosensor technologies have potential to deliver point-of-care diagnostics that match or surpass conventional standards in regards to time, accuracy and cost. Broadly classified as either label-free or labeled, modern biosensors exploit micro- and nanofabrication technologies and diverse sensing strategies including optical, electrical and mechanical transducers. Despite clinical need, translation of biosensors from research laboratories to clinical applications has remained limited to a few notable examples, such as the glucose sensor. Challenges to be overcome include sample preparation, matrix effects and system integration. We review the advances of biosensors for infectious disease diagnostics and discuss the critical challenges that need to be overcome in order to implement integrated diagnostic biosensors in real world settings. PMID:24524681
Fukushi, Shuetsu; Tani, Hideki; Yoshikawa, Tomoki; Saijo, Masayuki; Morikawa, Shigeru
2012-10-12
The family Arenaviridae, genus Arenavirus, consists of two phylogenetically independent groups: Old World (OW) and New World (NW) complexes. The Lassa and Lujo viruses in the OW complex and the Guanarito, Junin, Machupo, Sabia, and Chapare viruses in the NW complex cause viral hemorrhagic fever (VHF) in humans, leading to serious public health concerns. These viruses are also considered potential bioterrorism agents. Therefore, it is of great importance to detect these pathogens rapidly and specifically in order to minimize the risk and scale of arenavirus outbreaks. However, these arenaviruses are classified as BSL-4 pathogens, thus making it difficult to develop diagnostic techniques for these virus infections in institutes without BSL-4 facilities. To overcome these difficulties, antibody detection systems in the form of an enzyme-linked immunosorbent assay (ELISA) and an indirect immunofluorescence assay were developed using recombinant nucleoproteins (rNPs) derived from these viruses. Furthermore, several antigen-detection assays were developed. For example, novel monoclonal antibodies (mAbs) to the rNPs of Lassa and Junin viruses were generated. Sandwich antigen-capture (Ag-capture) ELISAs using these mAbs as capture antibodies were developed and confirmed to be sensitive and specific for detecting the respective arenavirus NPs. These rNP-based assays were proposed to be useful not only for an etiological diagnosis of VHFs, but also for seroepidemiological studies on VHFs. We recently developed arenavirus neutralization assays using vesicular stomatitis virus (VSV)-based pseudotypes bearing arenavirus recombinant glycoproteins. The goal of this article is to review the recent advances in developing laboratory diagnostic assays based on recombinant viral proteins for the diagnosis of VHFs and epidemiological studies on the VHFs caused by arenaviruses.
The Roadmap: Future Opportunities for Bioengagement in the MENA Region
2013-12-01
research to improving biosafety and biosecurity training of laboratory staff, enhancing physical security of research and diagnostic facilities, and...enhancing laboratory and institutional capacity to address biological risks according to international standards ; or building scientific capacity...outbreaks. BEP often supports scientific exchanges to enhance laboratory biosafety and biosecurity training; it could enrich its efforts by
NASA Astrophysics Data System (ADS)
Krupka, M.; Kalal, M.; Dostal, J.; Dudzak, R.; Juha, L.
2017-08-01
Classical interferometry became widely used method of active optical diagnostics. Its more advanced version, allowing reconstruction of three sets of data from just one especially designed interferogram (so called complex interferogram) was developed in the past and became known as complex interferometry. Along with the phase shift, which can be also retrieved using classical interferometry, the amplitude modifications of the probing part of the diagnostic beam caused by the object under study (to be called the signal amplitude) as well as the contrast of the interference fringes can be retrieved using the complex interferometry approach. In order to partially compensate for errors in the reconstruction due to imperfections in the diagnostic beam intensity structure as well as for errors caused by a non-ideal optical setup of the interferometer itself (including the quality of its optical components), a reference interferogram can be put to a good use. This method of interferogram analysis of experimental data has been successfully implemented in practice. However, in majority of interferometer setups (especially in the case of the ones employing the wavefront division) the probe and the reference part of the diagnostic beam would feature different intensity distributions over their respective cross sections. This introduces additional error into the reconstruction of the signal amplitude and the fringe contrast, which cannot be resolved using the reference interferogram only. In order to deal with this error it was found that additional separately recorded images of the intensity distribution of the probe and the reference part of the diagnostic beam (with no signal present) are needed. For the best results a sufficient shot-to-shot stability of the whole diagnostic system is required. In this paper, efficiency of the complex interferometry approach for obtaining the highest possible accuracy of the signal amplitude reconstruction is verified using the computer generated complex and reference interferograms containing artificially introduced intensity variations in the probe and the reference part of the diagnostic beam. These sets of data are subsequently analyzed and the errors of the signal amplitude reconstruction are evaluated.
Polish Code of Ethics of a Medical Laboratory Specialist
2014-01-01
Along with the development of medicine, increasingly significant role has been played by the laboratory diagnostics. For over ten years the profession of the medical laboratory specialist has been regarded in Poland as the autonomous medical profession and has enjoyed a status of one of public trust. The process of education of medical laboratory specialists consists of a five-year degree in laboratory medicine, offered at Medical Universities, and of a five-year Vocational Specialization in one of the fields of laboratory medicine such as clinical biochemistry, medical microbiology, medical laboratory toxicology, medical laboratory cytomorphology and medical laboratory transfusiology. An important component of medical laboratory specialists’ identity is awareness of inherited ethos obtained from bygone generations of workers in this particular profession and the need to continue its further development. An expression of this awareness is among others Polish Code of Ethics of a Medical Laboratory Specialist (CEMLS) containing a set of values and a moral standpoint characteristic of this type of professional environment. Presenting the ethos of the medical laboratory specialist is a purpose of this article. Authors focus on the role CEMLS plays in areas of professional ethics and law. Next, they reconstruct the Polish model of ethos of medical diagnostic laboratory personnel. An overall picture consists of a presentation of the general moral principles concerning execution of this profession and rules of conduct in relations with the patient, own professional environment and the rest of the society. Polish model of ethical conduct, which is rooted in Hippocratic medical tradition, harmonizes with the ethos of medical laboratory specialists of other European countries and the world. PMID:27683468
Polish Code of Ethics of a Medical Laboratory Specialist.
Elżbieta, Puacz; Waldemar, Glusiec; Barbara, Madej-Czerwonka
2014-09-01
Along with the development of medicine, increasingly significant role has been played by the laboratory diagnostics. For over ten years the profession of the medical laboratory specialist has been regarded in Poland as the autonomous medical profession and has enjoyed a status of one of public trust. The process of education of medical laboratory specialists consists of a five-year degree in laboratory medicine, offered at Medical Universities, and of a five-year Vocational Specialization in one of the fields of laboratory medicine such as clinical biochemistry, medical microbiology, medical laboratory toxicology, medical laboratory cytomorphology and medical laboratory transfusiology. An important component of medical laboratory specialists' identity is awareness of inherited ethos obtained from bygone generations of workers in this particular profession and the need to continue its further development. An expression of this awareness is among others Polish Code of Ethics of a Medical Laboratory Specialist (CEMLS) containing a set of values and a moral standpoint characteristic of this type of professional environment. Presenting the ethos of the medical laboratory specialist is a purpose of this article. Authors focus on the role CEMLS plays in areas of professional ethics and law. Next, they reconstruct the Polish model of ethos of medical diagnostic laboratory personnel. An overall picture consists of a presentation of the general moral principles concerning execution of this profession and rules of conduct in relations with the patient, own professional environment and the rest of the society. Polish model of ethical conduct, which is rooted in Hippocratic medical tradition, harmonizes with the ethos of medical laboratory specialists of other European countries and the world.
Current methods of laboratory diagnosis of Chlamydia trachomatis infections.
Black, C M
1997-01-01
Infections caused by Chlamydia trachomatis are probably the most common sexually transmitted diseases in the United States. Commonly unrecognized and often inadequately treated, chlamydial infections can ascend the reproductive tract and cause pelvic inflammatory disease, which often results in the devastating consequences of infertility, ectopic pregnancy, or chronic pelvic pain. C. trachomatis infections are also known to increase the risk for human immunodeficiency virus infection. The obligate intracellular life cycle of C. trachomatis has traditionally required laboratory diagnostic tests that are technically demanding, labor-intensive, expensive, and difficult to access. In spite of these historical challenges, however, laboratory diagnosis of C. trachomatis has been a rapidly advancing area in which there is presently a wide array of commercial diagnostic technologies, costs, manufacturers. This review describes and compares the diagnostic methods for C. trachomatis infection that are currently approved for use in the United States, including the newest DNA amplification technologies which are yet to be licensed for commercial use. Issues to consider in selecting a test for purposes of screening versus diagnosis based on prevalence, performance, legal, social, and cost issues are also discussed. PMID:8993862
Application of the MALDI Biotyper to clinical microbiology: progress and potential.
Kostrzewa, Markus
2018-03-01
The introduction of the MALDI Biotyper in laboratories substantially changed microbiology practice, this has been called a revolution. The system accelerated diagnostic while costs were reduced and accuracy was increased. In just a few years MALDI-TOF MS became the first-line identification tool for microorganisms. Ten years after its introduction, more than 2000 MALDI Biotyper systems are installed in laboratories which are performing routine diagnostic, and the number is still increasing. Areas covered: This article summarises changes in clinical microbiology introduced by the MALDI Biotyper and its effects, as it has been published in peer reviewed articles found in PubMed. Further, the potential of novel developments to increase the value of the system is described. Expert commentary: The MALDI Biotyper has significantly improved clinical microbiology in the area of microorganism identification. Now new developments and applications, e.g. for typing and resistance testing, might further increase its value in clinical microbiology. The systems might get the central diagnostic analyser which is getting integrated into the widely automated microbiology laboratories of the future.
Ciardo, Diana E.; Lucke, Katja; Imhof, Alex; Bloemberg, Guido V.; Böttger, Erik C.
2010-01-01
The implementation of internal transcribed spacer (ITS) sequencing for routine identification of molds in the diagnostic mycology laboratory was analyzed in a 5-year study. All mold isolates (n = 6,900) recovered in our laboratory from 2005 to 2009 were included in this study. According to a defined work flow, which in addition to troublesome phenotypic identification takes clinical relevance into account, 233 isolates were subjected to ITS sequence analysis. Sequencing resulted in successful identification for 78.6% of the analyzed isolates (57.1% at species level, 21.5% at genus level). In comparison, extended in-depth phenotypic characterization of the isolates subjected to sequencing achieved taxonomic assignment for 47.6% of these, with a mere 13.3% at species level. Optimization of DNA extraction further improved the efficacy of molecular identification. This study is the first of its kind to testify to the systematic implementation of sequence-based identification procedures in the routine workup of mold isolates in the diagnostic mycology laboratory. PMID:20573873
Translational health economics: The key to accountable adoption of in vitro diagnostic technologies.
Price, Christopher P; Wolstenholme, Jane; McGinley, Patrick; St John, Andrew
2018-02-01
Adoption of new technologies, including diagnostic tests, is often considered not to deliver the expected return on investment. The reasons for this poor link between expectation and outcome include lack of evidence, variation in use of the technology, and an inability of the health system to manage the balance between investment and disinvestment associated with the change in care pathway. The challenges lie in the complex nature of healthcare provision where the investment is likely to be made in the jurisdiction of one stakeholder while the benefits (as well as dis-benefits) accrue to the other stakeholders. A prime example is found in the field of laboratory medicine and the use of diagnostic tests. The current economic tools employed in healthcare are primarily used to make policy and strategic decisions, particularly across health systems, and in purchaser and provider domains. These tools primarily involve cost effectiveness and budget impact analyses, both of which have been applied in health technology assessment of diagnostic technologies. However, they lack the granularity to translate findings down to the financial management and operational decision making at the provider department level. We propose an approach to translational health economics based on information derived from service line management and time-driven activity-based costing, identifying the resource utilisation for each of the units involved in the delivery of a care pathway, before and after adoption of new technology. This will inform investment and disinvestment decisions, along with identifying where the benefits, and dis-benefits, can be achieved for all stakeholders.
A Biosecurity Survey in Kenya, November 2014 to February 2015.
Ndhine, Edwardina Otieno; Slotved, Hans-Christian; Osoro, Eric Mogaka; Olsen, Katja N; Rugutt, Moses; Wanjohi, Cathryn W; Mwanda, Walter; Kinyagia, Benson Mburu; Steenhard, Nina R; Hansen, John-Erik Stig
2016-01-01
A biosecurity survey was performed to gather information on the biosecurity level and laboratory capacity in Kenya for the purpose of providing information outlining relevant components for biosecurity legislation, biosecurity implementation, and enforcement of biosecurity measures in Kenya. This survey is, to the authors' knowledge, the first to be published from an African country. A total of 86 facilities with laboratories covering relevant categories, such as training laboratories, human diagnostic laboratories, veterinary diagnostic laboratories, and research laboratories, were selected to participate in the survey. Each facility was visited by a survey team and staff were asked to answer 29 groups of questions from a questionnaire. The survey showed that Kenyan laboratory facilities contain biological agents of biosecurity concern. The restrictions for these agents were found to be limited for several of the facilities, in that many laboratory facilities and storage units were open for access by either students or staff who had no need of access to the laboratory. The survey showed a great deal of confusion in the terms biosecurity and biosafety and a generally limited biosecurity awareness among laboratory personnel. The survey showed that the security of biological agents of biosecurity concern in many facilities does not meet the international requirements. The authors recommend developing a legal framework in Kenya for effective controls, including national biosecurity regulations, guidelines, and procedures, thereby reducing the risk that a Kenyan laboratory would be the source of a future biological attack.
National and international veterinary reference laboratories for infectious diseases.
Edwards, S; Alexander, D
1998-08-01
Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.
76 FR 33303 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-08
... comments should be received within 60 days of this notice. Proposed Project Survey of Rapid Influenza... Description The Survey of Rapid Influenza Diagnostic Testing Practices in Clinical Laboratories is a national systematic study investigating rapid influenza diagnostic testing practices in clinical [[Page 33304...
When BVD doesn't look like BVD
USDA-ARS?s Scientific Manuscript database
Due to the sheer number of different clinical presentations existing under the BVD umbrella, diagnosing BVD based on clinical signs is not advisable. Thus diagnosis relies upon testing of samples in diagnostic laboratories. In the US, most of the diagnostic effort has been focused on identifying a...
Clinical chemistry through Clinical Chemistry: a journal timeline.
Rej, Robert
2004-12-01
The establishment of the modern discipline of clinical chemistry was concurrent with the foundation of the journal Clinical Chemistry and that of the American Association for Clinical Chemistry in the late 1940s and early 1950s. To mark the 50th volume of this Journal, I chronicle and highlight scientific milestones, and those within the discipline, as documented in the pages of Clinical Chemistry. Amazing progress has been made in the field of laboratory diagnostics over these five decades, in many cases paralleling-as well as being bolstered by-the rapid pace in the development of computer technologies. Specific areas of laboratory medicine particularly well represented in Clinical Chemistry include lipids, endocrinology, protein markers, quality of laboratory measurements, molecular diagnostics, and general advances in methodology and instrumentation.
Mu, Wenbo; Lu, Hsiao-Mei; Chen, Jefferey; Li, Shuwei; Elliott, Aaron M
2016-11-01
Next-generation sequencing (NGS) has rapidly replaced Sanger sequencing as the method of choice for diagnostic gene-panel testing. For hereditary-cancer testing, the technical sensitivity and specificity of the assay are paramount as clinicians use results to make important clinical management and treatment decisions. There is significant debate within the diagnostics community regarding the necessity of confirming NGS variant calls by Sanger sequencing, considering that numerous laboratories report having 100% specificity from the NGS data alone. Here we report our results from 20,000 hereditary-cancer NGS panels spanning 47 genes, in which all 7845 nonpolymorphic variants were Sanger- sequenced. Of these, 98.7% were concordant between NGS and Sanger sequencing and 1.3% were identified as NGS false-positives, located mainly in complex genomic regions (A/T-rich regions, G/C-rich regions, homopolymer stretches, and pseudogene regions). Simulating a false-positive rate of zero by adjusting the variant-calling quality-score thresholds decreased the sensitivity of the assay from 100% to 97.8%, resulting in the missed detection of 176 Sanger-confirmed variants, the majority in complex genomic regions (n = 114) and mosaic mutations (n = 7). The data illustrate the importance of setting quality thresholds for panel testing only after thousands of samples have been processed and the necessity of Sanger confirmation of NGS variants to maintain the highest possible sensitivity. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
[The characteristics of medical technologies in emergency medical care hospital].
Murakhovskiĭ, A G; Babenko, A I; Bravve, Iu I; Tataurova, E A
2013-01-01
The article analyzes the implementation of major 12 diagnostic and 17 treatment technologies applied during medical care of patients with 12 key nosology forms of diseases in departments of the emergency medical care hospital No 2 of Omsk. It is established that key groups of technologies in the implementation of diagnostic process are the laboratory clinical diagnostic analyses and common diagnostic activities at reception into hospital and corresponding departments. The percentage of this kind of activities is about 78.3% of all diagnostic technologies. During the realization of treatment process the priority technologies are common curative and rehabilitation activities, intensive therapy activities and clinical diagnostic monitoring activities. All of them consist 80.1% of all curative technologies.
de Almeida, Isabela N.; de Assis Figueredo, Lida J.; Soares, Valéria M.; Vater, Maria C.; Alves, Suely; da Silva Carvalho, Wânia; Kritski, Afrânio L.; de Miranda, Silvana S.
2017-01-01
At a global level, with the increase in healthcare costs, there is a need to assess the economic impact of the incorporation of new technologies in different health disorders in different countries. There is scarce information regarding costs incurred with the use of current or new diagnostic tests for tuberculosis or from the vantage point of their incorporation within the healthcare systems of high-burden countries. The present study aimed to assess the mean cost and the activity based cost of the laboratory diagnosis for tuberculosis by means of conventional techniques and from the Detect TB®LabTest molecular test kit in a general high-complexity hospital of the public health system in Brazil. Cost analysis was performed by means of primary data, collected in the Mycobacteria and Molecular Biology Laboratory in 2013. The mean cost and activity based cost were, respectively, U$10.06/U$5.61 for centrifuged bacilloscopy by Ziehl Neelsen (ZN) and Auramine (AU); U$7.42/U$4.15 for direct bacilloscopy by ZN; U$27.38/U$16.50 for culture in a Loweinstein-Jensen solid medium; and U$115.74/U$73.46 for the Detect TB®LabTest Kit. The calculation of the ABC should be used in making decisions by administrators to be the best method of assessing the costs of conventional techniques and molecular method for providing the real value of the tests. So it is need to calculate the ABC, and not of the mean cost, in various scenarios before incorporating new technologies in health institutions. PMID:28261194
Bone sialoprotein in laboratory diagnostic work-up of osteoarthritis.
Lis, Kinga
2008-01-01
Changes in osteoarthritis joint appear in the articular cartilage, synovium and in subchondral bone. It is necessary to find, apart from markers of cartilage destruction, a sensitive and specific biochemical marker which would reflect the metabolism as well as degradation of subchondral bone. Bone sialoprotein is mostly synthesized in osseous tissue found directly under the surface of joint cartilage. As a result, it is being increasingly perceived as a valuable marker of the metabolism rate of this layer of bone. Bone sialoprotein seems to be of use as a marker for subchondral bone degradation rate in laboratory diagnostic work-up of osteoarthritis.
Laboratory Diagnosis of Infective Endocarditis
Liesman, Rachael M.; Pritt, Bobbi S.; Maleszewski, Joseph J.
2017-01-01
ABSTRACT Infective endocarditis is life-threatening; identification of the underlying etiology informs optimized individual patient management. Changing epidemiology, advances in blood culture techniques, and new diagnostics guide the application of laboratory testing for diagnosis of endocarditis. Blood cultures remain the standard test for microbial diagnosis, with directed serological testing (i.e., Q fever serology, Bartonella serology) in culture-negative cases. Histopathology and molecular diagnostics (e.g., 16S rRNA gene PCR/sequencing, Tropheryma whipplei PCR) may be applied to resected valves to aid in diagnosis. Herein, we summarize recent knowledge in this area and propose a microbiologic and pathological algorithm for endocarditis diagnosis. PMID:28659319
A laboratory system for element specific hyperspectral X-ray imaging.
Jacques, Simon D M; Egan, Christopher K; Wilson, Matthew D; Veale, Matthew C; Seller, Paul; Cernik, Robert J
2013-02-21
X-ray tomography is a ubiquitous tool used, for example, in medical diagnosis, explosives detection or to check structural integrity of complex engineered components. Conventional tomographic images are formed by measuring many transmitted X-rays and later mathematically reconstructing the object, however the structural and chemical information carried by scattered X-rays of different wavelengths is not utilised in any way. We show how a very simple; laboratory-based; high energy X-ray system can capture these scattered X-rays to deliver 3D images with structural or chemical information in each voxel. This type of imaging can be used to separate and identify chemical species in bulk objects with no special sample preparation. We demonstrate the capability of hyperspectral imaging by examining an electronic device where we can clearly distinguish the atomic composition of the circuit board components in both fluorescence and transmission geometries. We are not only able to obtain attenuation contrast but also to image chemical variations in the object, potentially opening up a very wide range of applications from security to medical diagnostics.
Synergisms between microbial pathogens in plant disease complexes: a growing trend
Lamichhane, Jay Ram; Venturi, Vittorio
2015-01-01
Plant diseases are often thought to be caused by one species or even by a specific strain. Microbes in nature, however, mostly occur as part of complex communities and this has been noted since the time of van Leeuwenhoek. Interestingly, most laboratory studies focus on single microbial strains grown in pure culture; we were therefore unaware of possible interspecies and/or inter-kingdom interactions of pathogenic microbes in the wild. In human and animal infections, it is now being recognized that many diseases are the result of multispecies synergistic interactions. This increases the complexity of the disease and has to be taken into consideration in the development of more effective control measures. On the other hand, there are only a few reports of synergistic pathogen–pathogen interactions in plant diseases and the mechanisms of interactions are currently unknown. Here we review some of these reports of synergism between different plant pathogens and their possible implications in crop health. Finally, we briefly highlight the recent technological advances in diagnostics as these are beginning to provide important insights into the microbial communities associated with complex plant diseases. These examples of synergistic interactions of plant pathogens that lead to disease complexes might prove to be more common than expected and understanding the underlying mechanisms might have important implications in plant disease epidemiology and management. PMID:26074945
Evaluating a mobile application for improving clinical laboratory test ordering and diagnosis.
Meyer, Ashley N D; Thompson, Pamela J; Khanna, Arushi; Desai, Samir; Mathews, Benji K; Yousef, Elham; Kusnoor, Anita V; Singh, Hardeep
2018-04-20
Mobile applications for improving diagnostic decision making often lack clinical evaluation. We evaluated if a mobile application improves generalist physicians' appropriate laboratory test ordering and diagnosis decisions and assessed if physicians perceive it as useful for learning. In an experimental, vignette study, physicians diagnosed 8 patient vignettes with normal prothrombin times (PT) and abnormal partial thromboplastin times (PTT). Physicians made test ordering and diagnosis decisions for 4 vignettes using each resource: a mobile app, PTT Advisor, developed by the Centers for Disease Control and Prevention (CDC)'s Clinical Laboratory Integration into Healthcare Collaborative (CLIHC); and usual clinical decision support. Then, physicians answered questions regarding their perceptions of the app's usefulness for diagnostic decision making and learning using a modified Kirkpatrick Training Evaluation Framework. Data from 368 vignettes solved by 46 physicians at 7 US health care institutions show advantages for using PTT Advisor over usual clinical decision support on test ordering and diagnostic decision accuracy (82.6 vs 70.2% correct; P < .001), confidence in decisions (7.5 vs 6.3 out of 10; P < .001), and vignette completion time (3:02 vs 3:53 min.; P = .06). Physicians reported positive perceptions of the app's potential for improved clinical decision making, and recommended it be used to address broader diagnostic challenges. A mobile app, PTT Advisor, may contribute to better test ordering and diagnosis, serve as a learning tool for diagnostic evaluation of certain clinical disorders, and improve patient outcomes. Similar methods could be useful for evaluating apps aimed at improving testing and diagnosis for other conditions.
Ogouyèmi-Hounto, A; Kinde-Gazard, D; Keke, C; Gonçalves, E; Alapini, N; Adjovi, F; Adisso, L; Bossou, C; Denon, Y V; Massougbodji, A
2013-02-01
The aim of the study was to determine the accuracy of a rapid diagnostic test (SD Bioline Malaria Ag P.f/ Pan®) and fluorescent microscopy (CyScope®) in confirming presumptive malaria diagnosis in Cotonou. Thick blood smear was used as the reference technique for comparison. Testing was conducted on persons between the ages of 6 months and 70 years at two hospitals from June to October 2010. If malaria was suspected in the sample by the nurse based on clinical findings and sent to laboratory for confirmation, one thick smear, one rapid diagnostic test and one slide for the fluorescent microscopy were performed. All tests were read in hospital laboratories involved with the quality control of thick blood smear in the parasitology laboratory of National University Hospital of Cotonou. A total of 354 patients with clinical diagnosis of malaria were included. Malaria prevalence determined by thick smear, rapid diagnostic test and fluorescent microscopy was 22.8%, 25.4%, and 25.1% respectively. The sensitivity, specificity, positive and negative predictive values compared to the thick smears were 96.3, 95.6, 86.7, and 98.9% for rapid diagnostic test; and 97.5, 96.7, 89.8, and 99.27% for fluorescent microscopy. With these performances, these tests meet acceptability standards recommended by WHO for rapid tests (sensitivity > 95%). These two methods have advantages for the confirmation of malaria diagnosis in peripheral health structures that lack the resources to conduct diagnosis confirmation by the thick blood smear.
Viral Hemorrhagic Fever Diagnostics
Racsa, Lori D.; Kraft, Colleen S.; Olinger, Gene G.; Hensley, Lisa E.
2016-01-01
There are 4 families of viruses that cause viral hemorrhagic fever (VHF), including Filoviridae. Ebola virus is one virus within the family Filoviridae and the cause of the current outbreak of VHF in West Africa. VHF-endemic areas are found throughout the world, yet traditional diagnosis of VHF has been performed in large reference laboratories centered in Europe and the United States. The large amount of capital needed, as well as highly trained and skilled personnel, has limited the availability of diagnostics in endemic areas except in conjunction with governmental and nongovernmental entities. However, rapid diagnosis of VHF is essential to efforts that will limit outbreaks. In addition, increased global travel suggests VHF diagnoses may be made outside of the endemic areas. Thus, understanding how to diagnose VHF is imperative for laboratories worldwide. This article reviews traditional and current diagnostic modalities for VHF. PMID:26354968
Tuberculous otitis media: a significant diagnostic challenge.
Vaamonde, Pedro; Castro, Crisanto; García-Soto, Nicolas; Labella, Torcuato; Lozano, Ascensión
2004-06-01
This study was undertaken to revise the diagnostic characteristics of tuberculous otitis media (TOM), a disorder that is often diagnosed late, leading to delay in specific treatment. Retrospective study of a longitudinal series of 10 TOM patients over a 7-year period at an institutional referral center. Most patients showed intractable otorrhea, moderately severe hearing loss, and necrotic eardrums with granulation tissue and single perforations. Multiple perforations, facial palsy, and cervical adenopathies were rare (<10% of patients). CT generally showed soft tissue involvement of the middle ear without bone erosion. The most effective laboratory test microbiological culture of exudate (diagnostic efficacy 71%). Specific antibiotic treatment was effective in all cases. The diagnosis of TOM remains a significant challenge for otorhinolaryngologists. If there are strong clinical grounds for suspicion, standard laboratory tests for tuberculosis should be repeated even if initially negative.
A real-time PCR diagnostic method for detection of Naegleria fowleri.
Madarová, Lucia; Trnková, Katarína; Feiková, Sona; Klement, Cyril; Obernauerová, Margita
2010-09-01
Naegleria fowleri is a free-living amoeba that can cause primary amoebic meningoencephalitis (PAM). While, traditional methods for diagnosing PAM still rely on culture, more current laboratory diagnoses exist based on conventional PCR methods; however, only a few real-time PCR processes have been described as yet. Here, we describe a real-time PCR-based diagnostic method using hybridization fluorescent labelled probes, with a LightCycler instrument and accompanying software (Roche), targeting the Naegleria fowleriMp2Cl5 gene sequence. Using this method, no cross reactivity with other tested epidemiologically relevant prokaryotic and eukaryotic organisms was found. The reaction detection limit was 1 copy of the Mp2Cl5 DNA sequence. This assay could become useful in the rapid laboratory diagnostic assessment of the presence or absence of Naegleria fowleri. Copyright 2009 Elsevier Inc. All rights reserved.
42 CFR 493.1441 - Condition: Laboratories performing high complexity testing; laboratory director.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; laboratory director. 493.1441 Section 493.1441 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...
42 CFR 493.1441 - Condition: Laboratories performing high complexity testing; laboratory director.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; laboratory director. 493.1441 Section 493.1441 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...
Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application.
Gong, Max M; Sinton, David
2017-06-28
Infectious diseases are a major global health issue. Diagnosis is a critical first step in effectively managing their spread. Paper-based microfluidic diagnostics first emerged in 2007 as a low-cost alternative to conventional laboratory testing, with the goal of improving accessibility to medical diagnostics in developing countries. In this review, we examine the advances in paper-based microfluidic diagnostics for medical diagnosis in the context of global health from 2007 to 2016. The theory of fluid transport in paper is first presented. The next section examines the strategies that have been employed to control fluid and analyte transport in paper-based assays. Tasks such as mixing, timing, and sequential fluid delivery have been achieved in paper and have enabled analytical capabilities comparable to those of conventional laboratory methods. The following section examines paper-based sample processing and analysis. The most impactful advancement here has been the translation of nucleic acid analysis to a paper-based format. Smartphone-based analysis is another exciting development with potential for wide dissemination. The last core section of the review highlights emerging health applications, such as male fertility testing and wearable diagnostics. We conclude the review with the future outlook, remaining challenges, and emerging opportunities.
Ronald, L A; Ling, D I; FitzGerald, J M; Schwartzman, K; Bartlett-Esquilant, G; Boivin, J-F; Benedetti, A; Menzies, D
2017-05-01
An increasing number of studies are using health administrative databases for tuberculosis (TB) research. However, there are limitations to using such databases for identifying patients with TB. To summarise validated methods for identifying TB in health administrative databases. We conducted a systematic literature search in two databases (Ovid Medline and Embase, January 1980-January 2016). We limited the search to diagnostic accuracy studies assessing algorithms derived from drug prescription, International Classification of Diseases (ICD) diagnostic code and/or laboratory data for identifying patients with TB in health administrative databases. The search identified 2413 unique citations. Of the 40 full-text articles reviewed, we included 14 in our review. Algorithms and diagnostic accuracy outcomes to identify TB varied widely across studies, with positive predictive value ranging from 1.3% to 100% and sensitivity ranging from 20% to 100%. Diagnostic accuracy measures of algorithms using out-patient, in-patient and/or laboratory data to identify patients with TB in health administrative databases vary widely across studies. Use solely of ICD diagnostic codes to identify TB, particularly when using out-patient records, is likely to lead to incorrect estimates of case numbers, given the current limitations of ICD systems in coding TB.
Leers, M P G; Keuren, J F W; Oosterhuis, W P
2010-12-01
In patients with inflammatory conditions, diagnosing classic iron deficiency or anemia of chronic disease is challenging. In this study, we assessed the diagnostic value of the so-called Thomas'-plot [soluble transferrin receptor (sTfR)/log ferritin (sTfr/log Ferr) and the reticulocyte hemoglobin equivalent (Ret-HE)] in the anemia work up of patients referred by general practitioners. During July 2008-March 2009, 337 consecutive patients were included because of lowered Hb values. The laboratory results of the first 133 consecutive patients were used to determine the cut-off values for the diagnostic plot. The laboratory results of these patients were assessed and interpreted independently by two investigators, blinded from sTfR/log Ferr and Ret-HE values. The following 204 patients were used to test the plot in practice. In 32% of the first 133 patients, no indication of the cause of anemia could be found. However, when using the diagnostic plot in the following 204 patients, this fraction decreased to 14%. The 'Thomas'-plot is of diagnostic value for distinguishing functional iron deficiency from classic iron deficiency in a patient population referred by general practitioners. © 2010 Blackwell Publishing Ltd.
Adoption of Lean Principles in a High-Volume Molecular Diagnostic Microbiology Laboratory
Mitchell, P. Shawn; Mandrekar, Jayawant N.
2014-01-01
Clinical laboratories are constantly facing challenges to do more with less, enhance quality, improve test turnaround time, and reduce operational expenses. Experience with adopting and applying lean concepts and tools used extensively in the manufacturing industry is described for a high-volume clinical molecular microbiology laboratory, illustrating how operational success and benefits can be achieved. PMID:24829247
Cost challenges for laboratory medicine automation in Africa.
Tanyanyiwa, Donald Moshen
2010-01-01
Automation in laboratory medicine is inevitable and the only way forward especially in Africa where the staff turnover is high due to migration of experienced staff to Europe and America. Described here are the common issues that laboratory Managers and Directors encounter when upgrading, replacing analytical systems as well as daily running of diagnostic laboratories. The rapid advancement driven by the first world where research facilities, resources and expertise are available has seen changes in the both the hardware and software utilised by analyzers every two to three years. The downside is that in the process of replacing/phasing out old analysers, the first world countries in some cases donate them to second and third world countries as refurbished analysers. Problems in obtaining spares ensue since the production of new analysers results in reduced production or even of old spares. Unavailability or delayed availability of spares results in suspension of diagnostic service by the recipient laboratory. In some areas costly modifications to the analysers or the location/building have had to done to suite local (African) conditions, hence the need for Laboratory managers to understand fully the analysers' operational requirements before purchasing or accepting donations.
Godfrey, Catherine C.; Michelow, Pamela M.; Godard, Mandana; Sahasrabuddhe, Vikrant V.; Darden, Janice; Firnhaber, Cynthia S.; Wetherall, Neal T.; Bremer, James; Coombs, Robert W.; Wilkin, Timothy
2014-01-01
Objectives To evaluate an external quality assurance (EQA) program for the laboratory diagnosis of human papillomavirus (HPV) disease that was established to improve international research capability within the Division of AIDS at the National Institute of Allergy and Infectious Disease–supported Adult AIDS Clinical Trials Group network. Methods A three-component EQA scheme was devised comprising assessments of diagnostic accuracy of cytotechnologists and pathologists using available EQA packages, review of quality and accuracy of clinical slides from local sites by an outside expert, and HPV DNA detection using the commercially available HPV test kit. Results Seven laboratories and 17 pathologists in Africa, India, and South America participated. EQA scores were suboptimal for standard packages in three of seven laboratories. There was good agreement between the local laboratory and the central reader 70% of the time (90% confidence interval, 42%-98%). Performance on the College of American Pathologists’ HPV DNA testing panel was successful in all laboratories tested. Conclusions The prequalifying EQA round identified correctable issues that will improve the laboratory diagnosis of HPV related cervical disease at the international sites and will provide a mechanism for ongoing education and continuous quality improvement. PMID:24225757
Background: Laboratory reports of mycobacteria isolation and identification are created during the clinical diagnostic process to differentiate Mycobacterium tuberculosis from nontuberculous mycobacteria (NTM). NTM isolation rates are expected to exceed rates of true NTM infectio...
Dogs have been studied for many years as a medical diagnostic tool to detect a pre-clinical disease state by sniffing emissions directly from a human or an in vitro biological sample. Some of the studies report high sensitivity and specificity in blinded case-control studies. How...
ERIC Educational Resources Information Center
Clark, Sherri; Smith, Geoffrey Battle
2004-01-01
Outbreak! is an online, interactive educational game that helps students and teachers learn and evaluate clinical microbiology skills. When the game was used in introductory microbiology laboratories, qualitative evaluation by students showed very positive responses and increased learning. Outbreak! allows students to design diagnostic tests and…
Molecular diagnosis of α-thalassemia in a multiethnic population.
Gilad, Oded; Shemer, Orna Steinberg; Dgany, Orly; Krasnov, Tanya; Nevo, Michal; Noy-Lotan, Sharon; Rabinowicz, Ron; Amitai, Nofar; Ben-Dor, Shifra; Yaniv, Isaac; Yacobovich, Joanne; Tamary, Hannah
2017-06-01
α-Thalassemia, one of the most common genetic diseases, is caused by deletions or point mutations affecting one to four α-globin genes. Molecular diagnosis is important to prevent the most severe forms of the disease. However, the diagnosis of α-thalassemia is complex due to a high variability of the genetic defects involved, with over 250 described mutations. We summarize herein the findings of genetic analyses of DNA samples referred to our laboratory for the molecular diagnosis of α-thalassemia, along with a detailed clinical description. We utilized a diagnostic algorithm including Gap-PCR, to detect known deletions, followed by sequencing of the α-globin gene, to identify known and novel point mutations, and multiplex ligation-dependent probe amplification (MLPA) for the diagnosis of rare or novel deletions. α-Thalassemia was diagnosed in 662 of 975 samples referred to our laboratory. Most commonly found were deletions (75.3%, including two novel deletions previously described by us); point mutations comprised 25.4% of the cases, including five novel mutations. Our population included mostly Jews (of Ashkenazi and Sephardic origin) and Muslim Arabs, who presented with a higher rate of point mutations and hemoglobin H disease. Overall, we detected 53 different genotype combinations causing a spectrum of clinical phenotypes, from asymptomatic to severe anemia. Our work constitutes the largest group of patients with α-thalassemia originating in the Mediterranean whose clinical characteristics and molecular basis have been determined. We suggest a diagnostic algorithm that leads to an accurate molecular diagnosis in multiethnic populations. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Griffiths, Rebecca L M; El-Shanawany, Tariq; Jolles, Stephen R A; Selwood, Clive; Heaps, Adrian G; Carne, Emily M; Williams, Paul E
2017-01-01
Allergy is diagnosed from typical symptoms, and tests are performed to incriminate the suspected precipitant. Skin prick tests (SPTs) are commonly performed, inexpensive, and give immediate results. Laboratory tests (ImmunoCAP) for serum allergen-specific IgE antibodies are usually performed more selectively. The immuno-solid phase allergen chip (ISAC) enables testing for specific IgE against multiple allergen components in a multiplex assay. We retrospectively analysed clinic letters, case notes, and laboratory results of 118 patients attending the National Adult Allergy Service at the University Hospital of Wales who presented diagnostic difficulty, to evaluate which testing strategy (SPT, ImmunoCAP, or ISAC) was the most appropriate to use to confirm the diagnosis in these complex patients, evaluated in a "real-life" clinical service setting. In patients with nut allergy, the detection rates of SPTs (56%) and ISAC (65%) were lower than those of ImmunoCAP (71%). ISAC had a higher detection rate (88%) than ImmunoCAP (69%) or SPT (33%) in the diagnosis of oral allergy syndrome. ImmunoCAP test results identified all 9 patients with anaphylaxis due to wheat allergy (100%), whereas ISAC was positive in only 6 of these 9 (67%). In this difficult diagnostic group, the ImmunoCAP test should be the preferred single test for possible allergy to nuts, wheat, other specific foods, and anaphylaxis of any cause. In these conditions, SPT and ISAC tests give comparable results. The most useful single test for oral allergy syndrome is ISAC, and SPT should be the preferred test for latex allergy. © 2017 S. Karger AG, Basel.
Giordano, P C; Plancke, A; Van Meir, C A; Janssen, C A H; Kok, P J M J; Van Rooijen-Nijdam, I H; Tanis, B C; van Huisseling, J C M; Versteegh, F G A
2006-08-01
We have offered, for the first time in The Netherlands, carrier diagnostics for hemoglobinopathies (HbP) to early pregnant women. The aim of this study was to establish whether carrier analysis would be welcome by the public and feasible at the outpatient level. One hundred and thirty-nine randomly selected women were informed and offered basic carrier diagnostics at the first pregnancy control. Carrier diagnostics was accepted by 136 women (97.8%). The population consisted of 31% of recent immigrants and 69% of native Dutch. One carrier of HbS and one of beta-thalassemia were found, both among the group of the recent immigrants. In both cases, partners were tested excluding a couple at risk. In addition, five carriers of alpha(+)-thalassemia were diagnosed at the molecular level, one of them in the native Dutch population. Basic carrier analysis was done both at the Hospital Laboratory and at the Reference Laboratory. No discrepancies were found. This pilot study shows that (1) as predicted the prevalence of risk-related HbP and of alpha(+)-thalassemia is high in the immigrant population. (2) The compliance with carrier analysis in both native Dutch and immigrants is virtually total and (3) carrier diagnosis in early pregnancy and partner analysis in Hospital Laboratories is possible and is an effective tool for primary prevention of HbP in The Netherlands.
Using the arthroscopic surgery skill evaluation tool as a pass-fail examination.
Koehler, Ryan J; Nicandri, Gregg T
2013-12-04
Examination of arthroscopic skill requires evaluation tools that are valid and reliable with clear criteria for passing. The Arthroscopic Surgery Skill Evaluation Tool was developed as a video-based assessment of technical skill with criteria for passing established by a panel of experts. The purpose of this study was to test the validity and reliability of the Arthroscopic Surgery Skill Evaluation Tool as a pass-fail examination of arthroscopic skill. Twenty-eight residents and two sports medicine faculty members were recorded performing diagnostic knee arthroscopy on a left and right cadaveric specimen in our arthroscopic skills laboratory. Procedure videos were evaluated with use of the Arthroscopic Surgery Skill Evaluation Tool by two raters blind to subject identity. Subjects were considered to pass the Arthroscopic Surgery Skill Evaluation Tool when they attained scores of ≥ 3 on all eight assessment domains. The raters agreed on a pass-fail rating for fifty-five of sixty videos rated with an interclass correlation coefficient value of 0.83. Ten of thirty participants were assigned passing scores by both raters for both diagnostic arthroscopies performed in the laboratory. Receiver operating characteristic analysis demonstrated that logging more than eighty arthroscopic cases or performing more than thirty-five arthroscopic knee cases was predictive of attaining a passing Arthroscopic Surgery Skill Evaluation Tool score on both procedures performed in the laboratory. The Arthroscopic Surgery Skill Evaluation Tool is valid and reliable as a pass-fail examination of diagnostic arthroscopy of the knee in the simulation laboratory. This study demonstrates that the Arthroscopic Surgery Skill Evaluation Tool may be a useful tool for pass-fail examination of diagnostic arthroscopy of the knee in the simulation laboratory. Further study is necessary to determine whether the Arthroscopic Surgery Skill Evaluation Tool can be used for the assessment of multiple arthroscopic procedures and whether it can be used to evaluate arthroscopic procedures performed in the operating room.
Submillimeter Spectroscopic Study of Semiconductor Processing Plasmas
NASA Astrophysics Data System (ADS)
Helal, Yaser H.
Plasmas used for manufacturing processes of semiconductor devices are complex and challenging to characterize. The development and improvement of plasma processes and models rely on feedback from experimental measurements. Current diagnostic methods are not capable of measuring absolute densities of plasma species with high resolution without altering the plasma, or without input from other measurements. At pressures below 100 mTorr, spectroscopic measurements of rotational transitions in the submillimeter/terahertz (SMM) spectral region are narrow enough in relation to the sparsity of spectral lines that absolute specificity of measurement is possible. The frequency resolution of SMM sources is such that spectral absorption features can be fully resolved. Processing plasmas are a similar pressure and temperature to the environment used to study astrophysical species in the SMM spectral region. Many of the molecular neutrals, radicals, and ions present in processing plasmas have been studied in the laboratory and their absorption spectra have been cataloged or are in the literature for the purpose of astrophysical study. Recent developments in SMM devices have made its technology commercially available for applications outside of specialized laboratories. The methods developed over several decades in the SMM spectral region for these laboratory studies are directly applicable for diagnostic measurements in the semiconductor manufacturing industry. In this work, a continuous wave, intensity calibrated SMM absorption spectrometer was developed as a remote sensor of gas and plasma species. A major advantage of intensity calibrated rotational absorption spectroscopy is its ability to determine absolute concentrations and temperatures of plasma species from first principles without altering the plasma environment. An important part of this work was the design of the optical components which couple 500 - 750 GHz radiation through a commercial inductively coupled plasma chamber. The measurement of transmission spectra was simultaneously fit for background and absorption signal. The measured absorption signal was used to calculate absolute densities and temperatures of polar species. Measurements of molecular species were demonstrated for inductively coupled plasmas.
Nonanalytic Laboratory Automation: A Quarter Century of Progress.
Hawker, Charles D
2017-06-01
Clinical laboratory automation has blossomed since the 1989 AACC meeting, at which Dr. Masahide Sasaki first showed a western audience what his laboratory had implemented. Many diagnostics and other vendors are now offering a variety of automated options for laboratories of all sizes. Replacing manual processing and handling procedures with automation was embraced by the laboratory community because of the obvious benefits of labor savings and improvement in turnaround time and quality. Automation was also embraced by the diagnostics vendors who saw automation as a means of incorporating the analyzers purchased by their customers into larger systems in which the benefits of automation were integrated to the analyzers.This report reviews the options that are available to laboratory customers. These options include so called task-targeted automation-modules that range from single function devices that automate single tasks (e.g., decapping or aliquoting) to multifunction workstations that incorporate several of the functions of a laboratory sample processing department. The options also include total laboratory automation systems that use conveyors to link sample processing functions to analyzers and often include postanalytical features such as refrigerated storage and sample retrieval.Most importantly, this report reviews a recommended process for evaluating the need for new automation and for identifying the specific requirements of a laboratory and developing solutions that can meet those requirements. The report also discusses some of the practical considerations facing a laboratory in a new implementation and reviews the concept of machine vision to replace human inspections. © 2017 American Association for Clinical Chemistry.
NASA Astrophysics Data System (ADS)
Shevchik, S. A.; Meerovich, Gennadii A.; Budzinskaya, M. V.; Ermakova, N. A.; Kharnas, Sergey S.; Loschenov, Victor B.
2004-06-01
A laser-spectroscopy complex was developed for fluorescent diagnostics and photodynamic therapy of age related macula degeneration using the Russian photosensitizer Photosense. The complex is based on slit lamp which was additionally equipped with an optical adapter, and the video adapter allows to combine the procedure of photodynamic therapy and the control of its carrying in the frame work of one procedure. The sensitivity and spatial resolution of the complex were investigated using a special test object. The availability of the developed complex and Photosense itself was examined on experimental animals.
Code of Federal Regulations, 2010 CFR
2010-10-01
... complexity testing; clinical consultant. 493.1415 Section 493.1415 Public Health CENTERS FOR MEDICARE... § 493.1415 Condition: Laboratories performing moderate complexity testing; clinical consultant. The laboratory must have a clinical consultant who meets the qualification requirements of § 493.1417 of this...
Lee, Mi-Kyung; Kim, Sinyoung; Kim, Mi-Na; Kweon, Oh Joo; Lim, Yong Kwan; Ki, Chang-Seok; Kim, Jae-Seok; Seong, Moon-Woo; Sung, Heungsup; Yong, Dongeun; Lee, Hyukmin; Choi, Jong-Rak; Kim, Jeong-Ho
2016-03-01
It is crucial to understand the current status of clinical laboratory practices for the largest outbreak of Middle East respiratory syndrome coronavirus (MERS-CoV) infections in the Republic of Korea to be well prepared for future emerging infectious diseases. We conducted a survey of 49 clinical laboratories in medical institutions and referral medical laboratories. A short questionnaire to survey clinical laboratory practices relating to MERS-CoV diagnostic testing was sent by email to the directors and clinical pathologists in charge of the clinical laboratories performing MERS-CoV testing. The survey focused on testing volume, reporting of results, resources, and laboratory safety. A total of 40 clinical laboratories responded to the survey. A total of 27,009 MERS-CoV real-time reverse transcription PCR (rRT-PCR) tests were performed. Most of the specimens were sputum (73.5%). The median turnaround time (TAT) was 5.29 hr (first and third quartile, 4.11 and 7.48 hr) in 26 medical institutions. The median TAT of more than a half of the laboratories (57.7%) was less than 6 hr. Many laboratories were able to perform tests throughout the whole week. Laboratory biosafety preparedness included class II biosafety cabinets (100%); separated pre-PCR, PCR, and post-PCR rooms (88.6%); negative pressure pretreatment rooms (48.6%); and negative pressure sputum collection rooms (20.0%). Clinical laboratories were able to quickly expand their diagnostic capacity in response to the 2015 MERS-CoV outbreak. Our results show that clinical laboratories play an important role in the maintenance and enhancement of laboratory response in preparation for future emerging infections.
Lee, Mi-Kyung; Kim, Sinyoung; Kim, Mi-Na; Kweon, Oh Joo; Lim, Yong Kwan; Ki, Chang-Seok; Kim, Jae-Seok; Seong, Moon-Woo; Sung, Heungsup; Yong, Dongeun; Lee, Hyukmin; Choi, Jong-Rak
2016-01-01
Background It is crucial to understand the current status of clinical laboratory practices for the largest outbreak of Middle East respiratory syndrome coronavirus (MERS-CoV) infections in the Republic of Korea to be well prepared for future emerging infectious diseases. Methods We conducted a survey of 49 clinical laboratories in medical institutions and referral medical laboratories. A short questionnaire to survey clinical laboratory practices relating to MERS-CoV diagnostic testing was sent by email to the directors and clinical pathologists in charge of the clinical laboratories performing MERS-CoV testing. The survey focused on testing volume, reporting of results, resources, and laboratory safety. Results A total of 40 clinical laboratories responded to the survey. A total of 27,009 MERS-CoV real-time reverse transcription PCR (rRT-PCR) tests were performed. Most of the specimens were sputum (73.5%). The median turnaround time (TAT) was 5.29 hr (first and third quartile, 4.11 and 7.48 hr) in 26 medical institutions. The median TAT of more than a half of the laboratories (57.7%) was less than 6 hr. Many laboratories were able to perform tests throughout the whole week. Laboratory biosafety preparedness included class II biosafety cabinets (100%); separated pre-PCR, PCR, and post-PCR rooms (88.6%); negative pressure pretreatment rooms (48.6%); and negative pressure sputum collection rooms (20.0%). Conclusions Clinical laboratories were able to quickly expand their diagnostic capacity in response to the 2015 MERS-CoV outbreak. Our results show that clinical laboratories play an important role in the maintenance and enhancement of laboratory response in preparation for future emerging infections. PMID:26709263
Raven, Stijn; Hautvast, Jeannine; Steenbergen, Jim van; Akkermans, Reinier; Weykamp, Cas; Smits, Francis; Hoebe, Christian; Vossen, Ann
2017-02-01
Post-vaccination testing after hepatitis B vaccination is indispensable to evaluate long-term immunological protection. Using a threshold level of antibodies against hepatitis B surface antigen (anti-HBs) to define serological protection, implies reproducible and valid measurements of different diagnostic assays. In this study we assess the performance of currently used anti-HBs assays. In 2013, 45 laboratories participated in an external quality assessment program using pooled anti-HBs serum samples around the cutoff values 10IU/l and 100IU/l. Laboratories used either Axsym (Abbott Laboratories), Architect (Abbott Laboratories), Access (Beckman-Coulter), ADVIA Centaur anti-HBs2 (Siemens Healthcare Diagnostics), Elecsys, Modular or Cobas (Roche Diagnostics) or Vidas Total Quick (Biomerieux) for anti-HBs titre quantification. We analysed covariance using mixed-model repeated measures. To assess sensitivity/specificity and agreement, a true positive or true negative result was defined as an anti-HBs titre respectively above or below the cutoff value by ≥4 of 6 assays. Different anti-HBs assays were associated with statistically significant (P<0.05) differences in anti-HBs titres in all dilutions. Sensitivity and specificity ranged respectively from 64%-100% and 95%-100%. Agreement between assays around an anti-HBs titre cutoff value of 10IU/l ranged from 93%-100% and was 44% for a cutoff value of 100IU/l. Around a cutoff value of 10IU/l use of the Access assay may result in false-negative results. Concerning the cutoff value of 100IU/l, a sample being classified below or above this cutoff relied heavily on the specific assay used, with both the Architect and the Access resulting in false-negative results. Copyright © 2016 Elsevier B.V. All rights reserved.
Current and emerging techniques for antibiotic susceptibility tests.
Syal, Karan; Mo, Manni; Yu, Hui; Iriya, Rafael; Jing, Wenwen; Guodong, Sui; Wang, Shaopeng; Grys, Thomas E; Haydel, Shelley E; Tao, Nongjian
2017-01-01
Infectious diseases caused by bacterial pathogens are a worldwide burden. Serious bacterial infection-related complications, such as sepsis, affect over a million people every year with mortality rates ranging from 30% to 50%. Crucial clinical microbiology laboratory responsibilities associated with patient management and treatment include isolating and identifying the causative bacterium and performing antibiotic susceptibility tests (ASTs), which are labor-intensive, complex, imprecise, and slow (taking days, depending on the growth rate of the pathogen). Considering the life-threatening condition of a septic patient and the increasing prevalence of antibiotic-resistant bacteria in hospitals, rapid and automated diagnostic tools are needed. This review summarizes the existing commercial AST methods and discusses some of the promising emerging AST tools that will empower humans to win the evolutionary war between microbial genes and human wits.
NASA Technical Reports Server (NTRS)
Otugen, M. Volkan; Popovic, Svetozar
1996-01-01
Ongoing research in Rayleigh scattering diagnostics for variable density low speed flow applications and for supersonic flow measurements are described. During the past several years, the focus has been on the development and use of a Nd:YAG-based Rayleigh scattering system with improved signal-to-noise characteristics and with applicability to complex, confined flows. This activity serves other research projects in the Aerodynamics Laboratory which require the non-contact, accurate, time-frozen measurement of gas density, pressure, and temperature (each separately), in a fairly wide dynamic range of each parameter. Recently, with the acquisition of a new seed-injected Nd:YAG laser, effort also has been directed to the development of a high-speed velocity probe based on a spectrally resolved Rayleigh scattering technique.
Current and emerging techniques for antibiotic susceptibility tests
Syal, Karan; Mo, Manni; Yu, Hui; Iriya, Rafael; Jing, Wenwen; Guodong, Sui; Wang, Shaopeng; Grys, Thomas E.; Haydel, Shelley E.; Tao, Nongjian
2017-01-01
Infectious diseases caused by bacterial pathogens are a worldwide burden. Serious bacterial infection-related complications, such as sepsis, affect over a million people every year with mortality rates ranging from 30% to 50%. Crucial clinical microbiology laboratory responsibilities associated with patient management and treatment include isolating and identifying the causative bacterium and performing antibiotic susceptibility tests (ASTs), which are labor-intensive, complex, imprecise, and slow (taking days, depending on the growth rate of the pathogen). Considering the life-threatening condition of a septic patient and the increasing prevalence of antibiotic-resistant bacteria in hospitals, rapid and automated diagnostic tools are needed. This review summarizes the existing commercial AST methods and discusses some of the promising emerging AST tools that will empower humans to win the evolutionary war between microbial genes and human wits. PMID:28638468
Good Laboratory Practices of Materials Testing at NASA White Sands Test Facility
NASA Technical Reports Server (NTRS)
Hirsch, David; Williams, James H.
2005-01-01
An approach to good laboratory practices of materials testing at NASA White Sands Test Facility is presented. The contents include: 1) Current approach; 2) Data analysis; and 3) Improvements sought by WSTF to enhance the diagnostic capability of existing methods.
77 FR 41188 - Clinical Laboratory Improvement Advisory Committee (CLIAC)
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-12
... technological advances, such as new test methods and the electronic transmission of laboratory information... potential need for educational materials and resources for sites that test under a Provider-performed Microscopy Certificate; and the increased use of culture-independent microbiology diagnostics and the impact...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-22
... Laboratory Improvement Amendments Categorization AGENCY: Food and Drug Administration, HHS. ACTION: Notice... for Clinical Laboratory Improvement Amendments of 1998 (CLIA) categorization of in vitro diagnostic... techniques, when appropriate, and other forms of information technology. Requests for CLIA Categorization--42...
Machinery Diagnostic Feature Extraction and Fusion Techniques Using Diverse Sources
2001-04-05
laboratories AMTEC Corporation P.O. Box 077777 500 Wynn Drive, Suite 314 Huntsville, AL 35807-7777 Huntsville, AL 35816-3429 chongchanlee(~hnt.wvlelabs.com...for helicopters. Other distinguished features of JAHUMS system developed by AMTEC Corporation and Wyle Laboratories Incorporated are their data
Moore, Andrew; Nelson, Christina; Molins, Claudia; Mead, Paul
2016-01-01
In the United States, Lyme disease is caused by Borrelia burgdorferi and transmitted to humans by blacklegged ticks. Patients with an erythema migrans lesion and epidemiologic risk can receive a diagnosis without laboratory testing. For all other patients, laboratory testing is necessary to confirm the diagnosis, but proper interpretation depends on symptoms and timing of illness. The recommended laboratory test in the United States is 2-tiered serologic analysis consisting of an enzyme-linked immunoassay or immunofluorescence assay, followed by reflexive immunoblotting. Sensitivity of 2-tiered testing is low (30%–40%) during early infection while the antibody response is developing (window period). For disseminated Lyme disease, sensitivity is 70%–100%. Specificity is high (>95%) during all stages of disease. Use of other diagnostic tests for Lyme disease is limited. We review the rationale behind current US testing guidelines, appropriate use and interpretation of tests, and recent developments in Lyme disease diagnostics. PMID:27314832
Munro, Sarah A; Lund, Steven P; Pine, P Scott; Binder, Hans; Clevert, Djork-Arné; Conesa, Ana; Dopazo, Joaquin; Fasold, Mario; Hochreiter, Sepp; Hong, Huixiao; Jafari, Nadereh; Kreil, David P; Łabaj, Paweł P; Li, Sheng; Liao, Yang; Lin, Simon M; Meehan, Joseph; Mason, Christopher E; Santoyo-Lopez, Javier; Setterquist, Robert A; Shi, Leming; Shi, Wei; Smyth, Gordon K; Stralis-Pavese, Nancy; Su, Zhenqiang; Tong, Weida; Wang, Charles; Wang, Jian; Xu, Joshua; Ye, Zhan; Yang, Yong; Yu, Ying; Salit, Marc
2014-09-25
There is a critical need for standard approaches to assess, report and compare the technical performance of genome-scale differential gene expression experiments. Here we assess technical performance with a proposed standard 'dashboard' of metrics derived from analysis of external spike-in RNA control ratio mixtures. These control ratio mixtures with defined abundance ratios enable assessment of diagnostic performance of differentially expressed transcript lists, limit of detection of ratio (LODR) estimates and expression ratio variability and measurement bias. The performance metrics suite is applicable to analysis of a typical experiment, and here we also apply these metrics to evaluate technical performance among laboratories. An interlaboratory study using identical samples shared among 12 laboratories with three different measurement processes demonstrates generally consistent diagnostic power across 11 laboratories. Ratio measurement variability and bias are also comparable among laboratories for the same measurement process. We observe different biases for measurement processes using different mRNA-enrichment protocols.
Karnpean, Rossarin; Fucharoen, Goonnapa; Pansuwan, Anupong; Changtrakul, Duangrudee; Fucharoen, Supan
2013-06-01
No external quality assessment program for hemoglobin (Hb) analysis in the prevention and control of thalassemia has been established in Thailand. To improve the first line provisional diagnostics, the first proficiency testing (PT) program has been established. External Hb controls prepared at our center were sent to Hb analysis laboratories all over the country. Three cycles per year were performed in 2010 and 2011. In each cycle, two control samples with corresponding hematological parameters, designated as husband and his pregnant wife were supplied for Hb analysis. Each member analyzed the control samples in their routine practices. The results of Hb analysis, laboratory interpretation and risk assessment of the expected fetus for severe thalassemia diseases targeted for prevention and control were entered into the report form and sent back to our center. Participants reports were analyzed and classified into four different quality groups; Excellent (when all the three parameters are correct), Good (correct Hb analysis and interpretation but incorrect risk assessment), Fair (correct Hb analysis but incorrect interpretation and risk assessment) and Needs improvement (incorrect Hb analysis). It was found that most participants could report correct Hb types and quantifications but some misinterpretations and risk assessments were noted. These were clearly seen when control samples with more complexity were supplied. These results indicate a further improvement is required in the laboratory interpretation and knowledge of the laboratory diagnosis of thalassemia. The established system should facilitate the prevention and control program of thalassemia in the region.
Machine learning in laboratory medicine: waiting for the flood?
Cabitza, Federico; Banfi, Giuseppe
2018-03-28
This review focuses on machine learning and on how methods and models combining data analytics and artificial intelligence have been applied to laboratory medicine so far. Although still in its infancy, the potential for applying machine learning to laboratory data for both diagnostic and prognostic purposes deserves more attention by the readership of this journal, as well as by physician-scientists who will want to take advantage of this new computer-based support in pathology and laboratory medicine.
Compounding diagnostic delays: a qualitative study of point-of-care testing in South Africa.
Engel, Nora; Davids, Malika; Blankvoort, Nadine; Pai, Nitika Pant; Dheda, Keertan; Pai, Madhukar
2015-04-01
Successful point-of-care (POC) testing (completion of test-and-treat cycle in one patient encounter) has immense potential to reduce diagnostic and treatment delays, and improve patient and public health outcomes. We explored what tests are done and how in public/private, rural/urban hospitals and clinics in South Africa and whether they can ensure successful POC testing. This qualitative research study examined POC testing across major diseases in Cape Town, Durban and Eastern Cape. We conducted 101 semi-structured interviews and seven focus group discussions with doctors, nurses, community health workers, patients, laboratory technicians, policymakers, hospital managers and diagnostic manufacturers. In South Africa, diagnostics are characterised by a centralised system. Most tests conducted on the spot can be made to work successfully as POC tests. The majority of public/private clinics and smaller hospitals send samples via couriers to centralised laboratories and retrieve results the same way, via internet, fax or phone. The main challenge to POC testing lies in transporting samples and results, while delays risk patient loss from diagnostic/treatment pathways. Strategies to deal with associated delays create new problems, such as artificially prolonged turnaround times, strains on human resources and quality of testing, compounding additional diagnostic and treatment delays. For POC testing to succeed, particular characteristics of diagnostic ecosystems and adaptations of professional practices to overcome associated challenges must be taken into account. © 2014 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Smith, B.
2015-12-01
In 2014, eight Department of Energy (DOE) national laboratories, four academic institutions, one company, and the National Centre for Atmospheric Research combined forces in a project called Accelerated Climate Modeling for Energy (ACME) with the goal to speed Earth system model development for climate and energy. Over the planned 10-year span, the project will conduct simulations and modeling on DOE's most powerful high-performance computing systems at Oak Ridge, Argonne, and Lawrence Berkeley Leadership Compute Facilities. A key component of the ACME project is the development of an interactive test bed for the advanced Earth system model. Its execution infrastructure will accelerate model development and testing cycles. The ACME Workflow Group is leading the efforts to automate labor-intensive tasks, provide intelligent support for complex tasks and reduce duplication of effort through collaboration support. As part of this new workflow environment, we have created a diagnostic, metric, and intercomparison Python framework, called UVCMetrics, to aid in the testing-to-production execution of the ACME model. The framework exploits similarities among different diagnostics to compactly support diagnosis of new models. It presently focuses on atmosphere and land but is designed to support ocean and sea ice model components as well. This framework is built on top of the existing open-source software framework known as the Ultrascale Visualization Climate Data Analysis Tools (UV-CDAT). Because of its flexible framework design, scientists and modelers now can generate thousands of possible diagnostic outputs. These diagnostics can compare model runs, compare model vs. observation, or simply verify a model is physically realistic. Additional diagnostics are easily integrated into the framework, and our users have already added several. Diagnostics can be generated, viewed, and manipulated from the UV-CDAT graphical user interface, Python command line scripts and programs, and web browsers. The framework is designed to be scalable to large datasets, yet easy to use and familiar to scientists using previous tools. Integration in the ACME overall user interface facilitates data publication, further analysis, and quick feedback to model developers and scientists making component or coupled model runs.
Samoĭlovich, E O; Semeĭko, G V; Ermolovich, M A; Svirchevskaia, E Iu
2010-01-01
To summarize data on laboratory diagnostics of prenatal and postnatal rubella and molecular monitoring of rubella virus circulation in Belarus obtained during implementation of rubella elimination program. Serum samples from 2314 persons were tested on the presence of IgM to rubella virus and measles virus (in case of negative result on rubella) using respective enzyme immunoassays. Virological testing using RT-PCR as well as genotyping on the basis of E1 gene fragment sequencing were also performed. Two viruses isolated in Belarus were set as reference strains of genotypes 1G and 1h. Implementation of laboratory diagnostics allowed to differentiate cases of rubella from other exanthematous infections, significantly increase the number of laboratory-confirmed cases among all reported cases, and show presence of endemic circulation of rubella virus strains of 3 different genotypes (1G, 1E, and 1h) in Belarus (2004-2006). In 2006, when relatively high incidence of rubella was reported in the country (24.39 per 100,000 population), the risk of congenital rubella syndrome was not less than 9 per 100,000 births. Conducted in October 2005-May 2006 additional rounds of immunization against rubella (>1 million people were vaccinated) decreased incidence to single cases. Obtained data show achievability of indigenous rubella elemination by 2010. Revealed genetic diversity of rubella virus strains allowed to update the International classification of wild rubella viruses.
Standard Mutation Nomenclature in Molecular Diagnostics
Ogino, Shuji; Gulley, Margaret L.; den Dunnen, Johan T.; Wilson, Robert B.
2007-01-01
To translate basic research findings into clinical practice, it is essential that information about mutations and variations in the human genome are communicated easily and unequivocally. Unfortunately, there has been much confusion regarding the description of genetic sequence variants. This is largely because research articles that first report novel sequence variants do not often use standard nomenclature, and the final genomic sequence is compiled over many separate entries. In this article, we discuss issues crucial to clear communication, using examples of genes that are commonly assayed in clinical laboratories. Although molecular diagnostics is a dynamic field, this should not inhibit the need for and movement toward consensus nomenclature for accurate reporting among laboratories. Our aim is to alert laboratory scientists and other health care professionals to the important issues and provide a foundation for further discussions that will ultimately lead to solutions. PMID:17251329
NASA Technical Reports Server (NTRS)
Murphy, Gerald B.; Lonngren, Karl E.
1986-01-01
The discoveries and experiments of the Plasma Diagnostic Package (PDP) on the OSS 1 and Spacelab 2 missions are reviewed, these results are compared with those of other space and laboratory experiments, and the implications for the understanding of large body interactions in a low Earth orbit (LEO) plasma environment are discussed. First a brief review of the PDP investigation, its instrumentation and experiments is presented. Next a summary of PDP results along with a comparison of those results with similar space or laboratory experiments is given. Last of all the implications of these results in terms of understanding fundamental physical processes that take place with large bodies in LEO is discussed and experiments to deal with these vital questions are suggested.
Changing needs, opportunities and constraints for the 21st century microbiology laboratory.
Van Eldere, J
2005-04-01
Clinical microbiologists and microbiology laboratories are experiencing changes due to evolving views on 'healthcare delivery' as an economic activity, due to changes in the medical environment and the demographics of the workforce, and technical evolution. Cost-effectiveness of laboratory procedures has been achieved through consolidation and integration of laboratories. Consolidation offers economy of scale and reduction in numbers of on-site staff, but also leads to separation of microbiologists from their clinical colleagues. Integration puts different laboratory disciplines under a single management, and leads to reorganisation of laboratories along common work-lines. Cost-savings combined with on-site availability of laboratories are achieved at the expense of a reduction in the influence of microbiologists in the daily running of the laboratory. Medically, there is growing emphasis on evidence-based diagnostics. Because of time-delays inherent in culturing, microbiology through rapid testing is mandatory. There is an increasing shortage in Europe and the USA of trained microbiology laboratory technicians and microbiologists. This reinforces the trend towards more automation and integration. Technological advances, particularly in molecular diagnostics, offer the possibility of rapid reporting and improvement of the impact of clinical microbiology on patient management. Molecular tests, however, fit perfectly the concept of an integrated laboratory and may further loosen the link between microbiologist and microbiology tests. The challenge for clinical microbiology will be to use new techniques to improve its cost-effectiveness and impact on infectious disease management. The future organisation of microbiology laboratories must support this but is itself of secondary importance. The training of future microbiologist must prepare them for this changing environment.
Interinstitutional review of slides for forensic pathology: types of inconsistencies.
Ersoy, Gokhan; Akyildiz, Elif Ulker; Korkmaz, Gulay; Albek, Emre
2010-09-01
Because of the specific structure of forensic medicine in Turkey, reexamination of histopathologic specimens is a frequent practice. The aim of the present study is the assessment of microscopic diagnostic consistency in forensic pathology between different laboratories. Reports of the Council of Forensic Medicine between 2001 and 2004 were examined, and 150 cases with second pathologic examination were found. Results of histopathologic reports from peripheral laboratories were compared with those made by the Council pathologists with regard to diagnostic consistency. Consistency was assessed in 3 groups and 1 subgroup. Group 1, consistent and minor inconsistency; includes a major consistency subgroup. Group 2, major inconsistency, is the second diagnosis which is lethal; group 3, major inconsistency, is the first diagnosis which is lethal. The lung was found to be the organ with the highest frequency of diagnostic major inconsistency (group 2 and 3) and major consistency. Bronchopneumonia was the most common diagnosis. The brain had the highest frequency of intercenter diagnostic overall consistency (90.2%, group 1). Myocardial infarction was the diagnosis most frequently rejected on reevaluation (group 3). In conclusion, forensic pathology requires different experience than surgical ones. In cases of discrepancy between the anamnesis of the lethal event and pathologic findings, reevaluation of specimen is mandatory to avoid any diagnostic errors. Quality assurance systems with all include internal and external control mechanisms will improve the diagnostic reliability.
Grunow, Roland; Ippolito, G; Jacob, D; Sauer, U; Rohleder, A; Di Caro, A; Iacovino, R
2014-01-01
Quality assurance exercises and networking on the detection of highly infectious pathogens (QUANDHIP) is a joint action initiative set up in 2011 that has successfully unified the primary objectives of the European Network on Highly Pathogenic Bacteria (ENHPB) and of P4-laboratories (ENP4-Lab) both of which aimed to improve the efficiency, effectiveness, and response capabilities of laboratories directed at protecting the health of European citizens against high consequence bacteria and viruses of significant public health concern. Both networks have established a common collaborative consortium of 37 nationally and internationally recognized institutions with laboratory facilities from 22 European countries. The specific objectives and achievements include the initiation and establishment of a recognized and acceptable quality assurance scheme, including practical external quality assurance exercises, comprising living agents, that aims to improve laboratory performance, accuracy, and detection capabilities in support of patient management and public health responses; recognized training schemes for diagnostics and handling of highly pathogenic agents; international repositories comprising highly pathogenic bacteria and viruses for the development of standardized reference material; a standardized and transparent Biosafety and Biosecurity strategy protecting healthcare personnel and the community in dealing with high consequence pathogens; the design and organization of response capabilities dealing with cross-border events with highly infectious pathogens including the consideration of diagnostic capabilities of individual European laboratories. The project tackled several sensitive issues regarding Biosafety, Biosecurity and "dual use" concerns. The article will give an overview of the project outcomes and discuss the assessment of potential "dual use" issues.
Discrepancies in reporting the CAG repeat lengths for Huntington's disease
Quarrell, Oliver W; Handley, Olivia; O'Donovan, Kirsty; Dumoulin, Christine; Ramos-Arroyo, Maria; Biunno, Ida; Bauer, Peter; Kline, Margaret; Landwehrmeyer, G Bernhard
2012-01-01
Huntington's disease results from a CAG repeat expansion within the Huntingtin gene; this is measured routinely in diagnostic laboratories. The European Huntington's Disease Network REGISTRY project centrally measures CAG repeat lengths on fresh samples; these were compared with the original results from 121 laboratories across 15 countries. We report on 1326 duplicate results; a discrepancy in reporting the upper allele occurred in 51% of cases, this reduced to 13.3% and 9.7% when we applied acceptable measurement errors proposed by the American College of Medical Genetics and the Draft European Best Practice Guidelines, respectively. Duplicate results were available for 1250 lower alleles; discrepancies occurred in 40% of cases. Clinically significant discrepancies occurred in 4.0% of cases with a potential unexplained misdiagnosis rate of 0.3%. There was considerable variation in the discrepancy rate among 10 of the countries participating in this study. Out of 1326 samples, 348 were re-analysed by an accredited diagnostic laboratory, based in Germany, with concordance rates of 93% and 94% for the upper and lower alleles, respectively. This became 100% if the acceptable measurement errors were applied. The central laboratory correctly reported allele sizes for six standard reference samples, blind to the known result. Our study differs from external quality assessment (EQA) schemes in that these are duplicate results obtained from a large sample of patients across the whole diagnostic range. We strongly recommend that laboratories state an error rate for their measurement on the report, participate in EQA schemes and use reference materials regularly to adjust their own internal standards. PMID:21811303
Grolla, Allen; Jones, Steven M.; Fernando, Lisa; Strong, James E.; Ströher, Ute; Möller, Peggy; Paweska, Janusz T.; Burt, Felicity; Pablo Palma, Pedro; Sprecher, Armand; Formenty, Pierre; Roth, Cathy; Feldmann, Heinz
2011-01-01
Background Marburg virus (MARV), a zoonotic pathogen causing severe hemorrhagic fever in man, has emerged in Angola resulting in the largest outbreak of Marburg hemorrhagic fever (MHF) with the highest case fatality rate to date. Methodology/Principal Findings A mobile laboratory unit (MLU) was deployed as part of the World Health Organization outbreak response. Utilizing quantitative real-time PCR assays, this laboratory provided specific MARV diagnostics in Uige, the epicentre of the outbreak. The MLU operated over a period of 88 days and tested 620 specimens from 388 individuals. Specimens included mainly oral swabs and EDTA blood. Following establishing on site, the MLU operation allowed a diagnostic response in <4 hours from sample receiving. Most cases were found among females in the child-bearing age and in children less than five years of age. The outbreak had a high number of paediatric cases and breastfeeding may have been a factor in MARV transmission as indicated by the epidemiology and MARV positive breast milk specimens. Oral swabs were a useful alternative specimen source to whole blood/serum allowing testing of patients in circumstances of resistance to invasive procedures but limited diagnostic testing to molecular approaches. There was a high concordance in test results between the MLU and the reference laboratory in Luanda operated by the US Centers for Disease Control and Prevention. Conclusions/Significance The MLU was an important outbreak response asset providing support in patient management and epidemiological surveillance. Field laboratory capacity should be expanded and made an essential part of any future outbreak investigation. PMID:21629730
International External Quality Assurance for Laboratory Diagnosis of Diphtheria ▿
Neal, S. E.; Efstratiou, A.
2009-01-01
The diphtheria surveillance network (DIPNET) encompassing National Diphtheria Reference Centers from 25 European countries is a Dedicated Surveillance Network recognized by the European Commission. A key DIPNET objective is the quality assessment of microbiological procedures for diphtheria across the European Union and beyond. A detailed questionnaire on the level of reference laboratory services and an external quality assessment (EQA) panel comprising six simulated throat specimens were sent to 34 centers. Twenty-three centers are designated National Diphtheria Reference Centers, with the laboratory in the United Kingdom being the only WHO Collaborating Centre. A variety of screening and identification tests were used, including the cysteinase test (20/34 centers), pyrazinamidase test (17/34 centers), and commercial kits (25/34 centers). The classic Elek test for toxigenicity testing is mostly used (28/34 centers), with variations in serum sources and antitoxin concentrations. Many laboratories reported problems obtaining Elek reagents or media. Only six centers produced acceptable results for all six specimens. Overall, 21% of identification and 13% of toxigenicity reports were unacceptable. Many centers could not isolate the target organism, and most found difficulties with the specimens that contained Corynebacterium striatum as a commensal contaminant. Nineteen centers generated either false-positive or negative toxigenic results, which may have caused inappropriate medical management. The discrepancies in this diphtheria diagnostics EQA alarmingly reflect the urgent need to improve laboratory performance in diphtheria diagnostics in Europe, standardize feasible and robust microbiological methods, and build awareness among public health authorities. Therefore, DIPNET recommends that regular workshops and EQA distributions for diphtheria diagnostics should be supported and maintained. PMID:19828749
Grunow, Roland; Ippolito, G.; Jacob, D.; Sauer, U.; Rohleder, A.; Di Caro, A.; Iacovino, R.
2014-01-01
Quality assurance exercises and networking on the detection of highly infectious pathogens (QUANDHIP) is a joint action initiative set up in 2011 that has successfully unified the primary objectives of the European Network on Highly Pathogenic Bacteria (ENHPB) and of P4-laboratories (ENP4-Lab) both of which aimed to improve the efficiency, effectiveness, and response capabilities of laboratories directed at protecting the health of European citizens against high consequence bacteria and viruses of significant public health concern. Both networks have established a common collaborative consortium of 37 nationally and internationally recognized institutions with laboratory facilities from 22 European countries. The specific objectives and achievements include the initiation and establishment of a recognized and acceptable quality assurance scheme, including practical external quality assurance exercises, comprising living agents, that aims to improve laboratory performance, accuracy, and detection capabilities in support of patient management and public health responses; recognized training schemes for diagnostics and handling of highly pathogenic agents; international repositories comprising highly pathogenic bacteria and viruses for the development of standardized reference material; a standardized and transparent Biosafety and Biosecurity strategy protecting healthcare personnel and the community in dealing with high consequence pathogens; the design and organization of response capabilities dealing with cross-border events with highly infectious pathogens including the consideration of diagnostic capabilities of individual European laboratories. The project tackled several sensitive issues regarding Biosafety, Biosecurity and “dual use” concerns. The article will give an overview of the project outcomes and discuss the assessment of potential “dual use” issues. PMID:25426479
Update on diagnostics for Phytophthora ramorum
Philip Berger
2006-01-01
Diagnostics used by the U.S. Department of Agriculture (USDA), to determine absence or presence of Phytophthora ramorum in plant samples, are based on a combination of tests and depend on collaboration with external laboratories. The system currently in place attempts to maximize limited resources and at the same time provide the most scientifically...
External Quality Assessment for Zika Virus Molecular Diagnostic Testing, Brazil.
Fischer, Carlo; Pedroso, Celia; Mendrone, Alfredo; Bispo de Filippis, Ana Maria; Vallinoto, Antonio Carlos Rosário; Ribeiro, Bergmann Morais; Durigon, Edison Luiz; Marques, Ernesto T A; Campos, Gubio S; Viana, Isabelle F T; Levi, José Eduardo; Scarpelli, Luciano Cesar; Nogueira, Mauricio Lacerda; Bastos, Michele de Souza; Souza, Nathalia C Santiago; Khouri, Ricardo; Lira, Sanny; Komninakis, Shirley Vasconcelos; Baronti, Cécile; Charrel, Rémi N; Kümmerer, Beate M; Drosten, Christian; Brites, Carlos; de Lamballerie, Xavier; Niedrig, Matthias; Netto, Eduardo Martins; Drexler, Jan Felix
2018-05-01
We conducted an external quality assessment of Zika virus molecular diagnostic tests in Brazil using a new Zika virus standard. Of 15 laboratories, 73% showed limited sensitivity and specificity. Viral load estimates varied significantly. Continuous quality assurance is needed to adequately estimate risk for Zika virus-associated disease and determine patient care.
An Interview with Medical Diagnostics Scientist Bernhard Weigl
ERIC Educational Resources Information Center
Sullivan, Megan
2010-01-01
Medical diagnostics help us evaluate a range of disorders, such as cancer and infectious diseases. In the United States and other developed countries, doctors have access to advanced equipment and laboratories that provide reliable diagnoses. As a result, when we are sick, we feel confident that we will get the treatment we need. Unfortunately,…
Molecular Methods and Platforms for Infectious Diseases Testing
Emmadi, Rajyasree; Boonyaratanakornkit, Jerry B.; Selvarangan, Rangaraj; Shyamala, Venkatakrishna; Zimmer, Barbara L.; Williams, Laurina; Bryant, Bonita; Schutzbank, Ted; Schoonmaker, Michele M.; Amos Wilson, Jean A.; Hall, Leslie; Pancholi, Preeti; Bernard, Kathryn
2011-01-01
The superior sensitivity and specificity associated with the use of molecular assays has greatly improved the field of infectious disease diagnostics by providing clinicians with results that are both accurate and rapidly obtained. Herein, we review molecularly based infectious disease diagnostic tests that are Food and Drug Administration approved or cleared and commercially available in the United States as of December 31, 2010. We describe specific assays and their performance, as stated in the Food and Drug Administration's Summary of Safety and Effectiveness Data or the Office of In Vitro Diagnostic Device Evaluation and Safety's decision summaries, product inserts, or peer-reviewed literature. We summarize indications for testing, limitations, and challenges related to implementation in a clinical laboratory setting for a wide variety of common pathogens. The information presented in this review will be particularly useful for laboratories that plan to implement or expand their molecular offerings in the near term. PMID:21871973
2013-01-01
An HIV-1 diagnostic laboratory was established in the Academic Medical Center (AMC) of the University of Amsterdam after the discovery of human immunodeficiency virus (HIV) as the cause of the acquired immunodeficiency syndrome (AIDS). The first AIDS patients were diagnosed here in 1981 and since 1983 we have tested the samples of 50992 patients using a variety of assays that greatly improved over the years. We will describe some of the basic results from this diagnostic laboratory and then focus on the spin-off in terms of the development of novel virus assays to detect super-infections and ultra-sensitive assays to measure the intracellular HIV-1 RNA load. We also review several original research findings in the field of HIV-1 virology that stem from initial observations made in the diagnostic unit. This includes the study of genetic defects in the HIV-1 genome and time trends of the replication fitness over 30 years of viral evolution, but also the description of novel HIV-1 variants in difficult-to-diagnose clinical specimen. PMID:23985078
van der Kuyl, Antoinette C; Bakker, Margreet; Jurriaans, Suzanne; Back, Nicole K T; Pasternak, Alexander O; Cornelissen, Marion; Berkhout, Ben
2013-08-28
An HIV-1 diagnostic laboratory was established in the Academic Medical Center (AMC) of the University of Amsterdam after the discovery of human immunodeficiency virus (HIV) as the cause of the acquired immunodeficiency syndrome (AIDS). The first AIDS patients were diagnosed here in 1981 and since 1983 we have tested the samples of 50992 patients using a variety of assays that greatly improved over the years. We will describe some of the basic results from this diagnostic laboratory and then focus on the spin-off in terms of the development of novel virus assays to detect super-infections and ultra-sensitive assays to measure the intracellular HIV-1 RNA load. We also review several original research findings in the field of HIV-1 virology that stem from initial observations made in the diagnostic unit. This includes the study of genetic defects in the HIV-1 genome and time trends of the replication fitness over 30 years of viral evolution, but also the description of novel HIV-1 variants in difficult-to-diagnose clinical specimen.
Strategies in Ebola virus disease (EVD) diagnostics at the point of care.
Coarsey, Chad T; Esiobu, Nwadiuto; Narayanan, Ramswamy; Pavlovic, Mirjana; Shafiee, Hadi; Asghar, Waseem
2017-11-01
Ebola virus disease (EVD) is a devastating, highly infectious illness with a high mortality rate. The disease is endemic to regions of Central and West Africa, where there is limited laboratory infrastructure and trained staff. The recent 2014 West African EVD outbreak has been unprecedented in case numbers and fatalities, and has proven that such regional outbreaks can become a potential threat to global public health, as it became the source for the subsequent transmission events in Spain and the USA. The urgent need for rapid and affordable means of detecting Ebola is crucial to control the spread of EVD and prevent devastating fatalities. Current diagnostic techniques include molecular diagnostics and other serological and antigen detection assays; which can be time-consuming, laboratory-based, often require trained personnel and specialized equipment. In this review, we discuss the various Ebola detection techniques currently in use, and highlight the potential future directions pertinent to the development and adoption of novel point-of-care diagnostic tools. Finally, a case is made for the need to develop novel microfluidic technologies and versatile rapid detection platforms for early detection of EVD.
Lutz, Barry; Liang, Tinny; Fu, Elain; Ramachandran, Sujatha; Kauffman, Peter; Yager, Paul
2013-07-21
Lateral flow tests (LFTs) are an ingenious format for rapid and easy-to-use diagnostics, but they are fundamentally limited to assay chemistries that can be reduced to a single chemical step. In contrast, most laboratory diagnostic assays rely on multiple timed steps carried out by a human or a machine. Here, we use dissolvable sugar applied to paper to create programmable flow delays and present a paper network topology that uses these time delays to program automated multi-step fluidic protocols. Solutions of sucrose at different concentrations (10-70% of saturation) were added to paper strips and dried to create fluidic time delays spanning minutes to nearly an hour. A simple folding card format employing sugar delays was shown to automate a four-step fluidic process initiated by a single user activation step (folding the card); this device was used to perform a signal-amplified sandwich immunoassay for a diagnostic biomarker for malaria. The cards are capable of automating multi-step assay protocols normally used in laboratories, but in a rapid, low-cost, and easy-to-use format.