Sample records for complex implant case

  1. An evidence-based concept of implant dentistry. Utilization of short and narrow platform implants.

    PubMed

    Ruiz, Jose-Luis

    2012-09-01

    As a profession, we must remember that tooth replacement is not a luxury; it is often a necessity for health reasons. Although bone augmentation and CBCT and expensive surgical guides are often indicated for complex cases, they are being overused. Simple or straightforward implant cases, when there is sufficient natural bone for narrow or shorter implant, can be predictable performed by well-trained GPs and other trained specialists. Complex cases requiring bone augmentation and other complexities as described herein, should be referred to a surgical specialist. Implant courses and curricula have to be based on the level of complexity of implant surgery that each clinician wishes to provide to his or her patients. Using a "logical approach" to implant dentistry keeps cases simple or straightforward, and more accessible to patients by the correct use of narrow and shorter implants.

  2. Low-Cost 3D Printing Orbital Implant Templates in Secondary Orbital Reconstructions.

    PubMed

    Callahan, Alison B; Campbell, Ashley A; Petris, Carisa; Kazim, Michael

    Despite its increasing use in craniofacial reconstructions, three-dimensional (3D) printing of customized orbital implants has not been widely adopted. Limitations include the cost of 3D printers able to print in a biocompatible material suitable for implantation in the orbit and the breadth of available implant materials. The authors report the technique of low-cost 3D printing of orbital implant templates used in complex, often secondary, orbital reconstructions. A retrospective case series of 5 orbital reconstructions utilizing a technique of 3D printed orbital implant templates is presented. Each patient's Digital Imaging and Communications in Medicine data were uploaded and processed to create 3D renderings upon which a customized implant was designed and sent electronically to printers open for student use at our affiliated institutions. The mock implants were sterilized and used intraoperatively as a stencil and mold. The final implant material was chosen by the surgeons based on the requirements of the case. Five orbital reconstructions were performed with this technique: 3 tumor reconstructions and 2 orbital fractures. Four of the 5 cases were secondary reconstructions. Molded Medpor Titan (Stryker, Kalamazoo, MI) implants were used in 4 cases and titanium mesh in 1 case. The stenciled and molded implants were adjusted no more than 2 times before anchored in place (mean 1). No case underwent further revision. The technique and cases presented demonstrate 1) the feasibility and accessibility of low-cost, independent use of 3D printing technology to fashion patient-specific implants in orbital reconstructions, 2) the ability to apply this technology to the surgeon's preference of any routinely implantable material, and 3) the utility of this technique in complex, secondary reconstructions.

  3. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.

    PubMed

    Merıç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; özden, Ahmet Utku

    2011-11-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone around the implants supporting cantilever fixed partial dentures (CFPDs) as well as in the implant-abutment complex and superstructures. The three-dimensional finite element method was selected to evaluate the stress distribution. CFPDs which was supported by microthread collar structured (MCS) and non-microthread collar structured (NMCS) implants was modeled; 300 N vertical, 150 N oblique and 60 N horizontal forces were applied to the models separately. The stress values in the bone, implant-abutment complex and superstructures were calculated. In the MCS model, higher stresses were located in the cortical bone and implant-abutment complex in the case of vertical load while decreased stresses in cortical bone and implant-abutment complex were noted within horizontal and oblique loading. In the case of vertical load, decreased stresses have been noted in cancellous bone and framework. Upon horizontal and oblique loading, a MCS model had higher stress in cancellous bone and framework than the NMCS model. Higher von Mises stresses have been noted in veneering material for NMCS models. It has been concluded that stress distribution in implant-supported CFPDs correlated with the macro design of the implant collar and the direction of applied force.

  4. The utility of 3D printing for surgical planning and patient-specific implant design for complex spinal pathologies: case report.

    PubMed

    Mobbs, Ralph J; Coughlan, Marc; Thompson, Robert; Sutterlin, Chester E; Phan, Kevin

    2017-04-01

    OBJECTIVE There has been a recent renewed interest in the use and potential applications of 3D printing in the assistance of surgical planning and the development of personalized prostheses. There have been few reports on the use of 3D printing for implants designed to be used in complex spinal surgery. METHODS The authors report 2 cases in which 3D printing was used for surgical planning as a preoperative mold, and for a custom-designed titanium prosthesis: one patient with a C-1/C-2 chordoma who underwent tumor resection and vertebral reconstruction, and another patient with a custom-designed titanium anterior fusion cage for an unusual congenital spinal deformity. RESULTS In both presented cases, the custom-designed and custom-built implants were easily slotted into position, which facilitated the surgery and shortened the procedure time, avoiding further complex reconstruction such as harvesting rib or fibular grafts and fashioning these grafts intraoperatively to fit the defect. Radiological follow-up for both cases demonstrated successful fusion at 9 and 12 months, respectively. CONCLUSIONS These cases demonstrate the feasibility of the use of 3D modeling and printing to develop personalized prostheses and can ease the difficulty of complex spinal surgery. Possible future directions of research include the combination of 3D-printed implants and biologics, as well as the development of bioceramic composites and custom implants for load-bearing purposes.

  5. Multidisciplinary Approach in the Management of a Complex Case: Implant-Prosthetic Rehabilitation of a Periodontal Smoking Patient with Partial Edentulism, Malocclusion, and Aesthetic Diseases

    PubMed Central

    Di Francesco, Fabrizio; De Marco, Gennaro; Scognamiglio, Fabio; Aruta, Valeria; Itro, Angelo

    2017-01-01

    Complex periprosthetic cases are considered as challenges by clinicians. Clinical and radiographic parameters should be considered separately to make the right choice between an endodontically or periodontally compromised treated tooth and implant. Therefore, in order to decide whether the tooth is safe or not, data that have to be collected are specific parameters of both the patient and the clinician. In addition, the presence of periodontal, prosthetic, and orthodontic diseases requires patients to be set in multidisciplinary approach. The aim of this case report is to describe how the multidisciplinary approach could be the best way to manage difficult cases of implant-prosthetic rehabilitation. How to rehabilitate with fixed prosthesis on natural teeth and dental implants a smoker patient who presents with active periodontitis, multiple edentulous areas, dental malocclusion, and severe aesthetic problems was also described. PMID:28421148

  6. [One-stage reconstruction of zygomatico-orbital complex with the use of implants of different origin].

    PubMed

    Menabde, G T; Gvenetadze, Z V; Atskvereli, L Sh

    2009-03-01

    Reconstruction of zygomatico-orbital complex remains as one of the troublesome and topical problems at steady posttraumatic deformations and fresh traumas of the mentioned region. The present work provides analysis of our own experience of surgical treatment of patients suffering from posttraumatic deformations and defects of zygomatico-orbital complex. The work was based on the results of examination and treatment of 33 patients who underwent an operation during the period from 2003 to 2008 years. Of 33, 21 patients were operated due to fresh traumas of the zygomatico-orbital region, and 12 - due to steady posttraumatic deformations of the mentioned region. Of 33 clinical cases, 19 patients underwent reconstruction of zygomatico-orbital complex with the use of implant. In 11 cases implants were perforated titanic plates, in 6 cases - bone cement (Surgical Simplex P), and in 2 cases - combination of titanic plates with bone cement. The results of our investigations have shown that one-stage reconstruction of zygomatico-orbital complex with the use of titanic plates and bone cement liquidates functional and cosmetic disorders. It has been suggested that the use of elaborated complex approaches in treatment of posttraumatic deformations and fresh traumas of zygomatico-orbital region is reasonable and acceptable.

  7. Surgical Management of Complex Lower-Extremity Trauma With a Long Hindfoot Fusion Nail: A Case Report.

    PubMed

    Jain, Nickul S; Lopez, Gregory D; Bederman, S Samuel; Wirth, Garrett A; Scolaro, John A

    2016-08-01

    High-energy injuries can result in complete or partial loss of the talus. Ipsilateral fractures to the lower limb increase the complexity of surgical management, and treatment is guided by previous case reports of similar injuries. A case of complex lower-extremity trauma with extruded and missing talar body and ipsilateral type IIIB open tibia fracture is presented. Surgical limb reconstruction and salvage was performed successfully with a single orthopaedic implant in a manner not described previously in the literature. The purpose of this case report is to present the novel use of a single orthopaedic implant for treatment of a complex, open traumatic injury. Previous case reports in the literature have described the management of complete or partial talar loss. We describe the novel use of a long hindfoot fusion nail and staged bone grafting to achieve tibiocalcaneal arthrodesis for the treatment of complex lower-extremity trauma. Therapeutic, Level IV: Case study. © 2015 The Author(s).

  8. Mucopolysaccharide complexes in the fibrous tissue surrounding hydrophilic polymers in subcutaneous implantation.

    PubMed

    Sprincl, L; Terescenko, T L; Kálal, J; Lipatova, T E; Kopecek, J; Pchakadze, G A

    1976-01-01

    The biocompatibility of three types of hydrophilic poly-(glycol methacrylate) gels--homogeneous, microporous and macroporous--was investigated in an experimental subcutaneous implantation. The occurrence of mucopolysaccharide complexes formed by both hyaluronic acid and chondroitine sulphates was examined in the fibrous tissue which surrounds the implant and penetrates into it in the case of a macroporous polymer. In an early stage of investigation hyaluronic acid prevails, but with proceeding collagenization the chondroitine sulphate part becomes predominant.

  9. Angulated Dental Implants in Posterior Maxilla FEA and Experimental Verification.

    PubMed

    Hamed, Hamed A; Marzook, Hamdy A; Ghoneem, Nahed E; El-Anwar, Mohamed I

    2018-02-15

    This study aimed to evaluate the effect of different implant angulations in posterior maxilla on stress distribution by finite element analysis and verify its results experimentally. Two simplified models were prepared for an implant placed vertically and tilted 25° piercing the maxillary sinus. Geometric models' components were prepared by Autodesk Inventor then assembled in ANSYS for finite element analysis. The results of finite element analysis were verified against experimental trials results which were statistically analysed using student t-test (level of significance p < 0.05). Implant - abutment complex absorbed the load energy in case of vertical implant better than the case of angulated one. That was reflected on cortical bone stress, while both cases showed stress levels within the physiological limits. Comparing results between FEA and experiment trials showed full agreement. It was found that the tilted implant by 25° can be utilised in the posterior region maxilla for replacing maxillary first molar avoiding sinus penetration. The implant-bone interface and peri-implant bones received the highest Von Mises stress. Implant - bone interface with angulated implant received about 66% more stresses than the straight one.

  10. Express implant in Urrets-Zavalia syndrome after descemet's stripping automated endothelial keratoplasty.

    PubMed

    Muñoz-Morales, A; del Trigo-Zamora, J R; Sánchez-Vicente, J L; Lozano-Bernal, O; Luchena-López, R

    2015-10-01

    The first case is described on a patient with Urrets-Zavalía syndrome after Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) in whom an ExPRESS implant was used. The ExPRESS implant is a useful tool for complex cases of post-surgical glaucoma where patients need to avoid post-operative inflammation and risks (corneal transplant patients). It is also very useful in cases with a high risk of fibrosis due to previous interventions. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  11. Angulated Dental Implants in Posterior Maxilla FEA and Experimental Verification

    PubMed Central

    Hamed, Hamed A.; Marzook, Hamdy A.; Ghoneem, Nahed E.; El–Anwar, Mohamed I.

    2018-01-01

    AIM: This study aimed to evaluate the effect of different implant angulations in posterior maxilla on stress distribution by finite element analysis and verify its results experimentally. METHODS: Two simplified models were prepared for an implant placed vertically and tilted 25° piercing the maxillary sinus. Geometric models’ components were prepared by Autodesk Inventor then assembled in ANSYS for finite element analysis. The results of finite element analysis were verified against experimental trials results which were statistically analysed using student t-test (level of significance p < 0.05). RESULTS: Implant - abutment complex absorbed the load energy in case of vertical implant better than the case of angulated one. That was reflected on cortical bone stress, while both cases showed stress levels within the physiological limits. Comparing results between FEA and experiment trials showed full agreement. CONCLUSION: It was found that the tilted implant by 25° can be utilised in the posterior region maxilla for replacing maxillary first molar avoiding sinus penetration. The implant-bone interface and peri-implant bones received the highest Von Mises stress. Implant - bone interface with angulated implant received about 66% more stresses than the straight one. PMID:29531612

  12. Computer-assisted innovations in craniofacial surgery.

    PubMed

    Rudman, Kelli; Hoekzema, Craig; Rhee, John

    2011-08-01

    Reconstructive surgery for complex craniofacial defects challenges even the most experienced surgeons. Preoperative reconstructive planning requires consideration of both functional and aesthetic properties of the mandible, orbit, and midface. Technological innovations allow for computer-assisted preoperative planning, computer-aided manufacturing of patient-specific implants (PSIs), and computer-assisted intraoperative navigation. Although many case reports discuss computer-assisted preoperative planning and creation of custom implants, a general overview of computer-assisted innovations is not readily available. This article reviews innovations in computer-assisted reconstructive surgery including anatomic considerations when using PSIs, technologies available for preoperative planning, work flow and process of obtaining a PSI, and implant materials available for PSIs. A case example follows illustrating the use of this technology in the reconstruction of an orbital-frontal-temporal defect with a PSI. Computer-assisted reconstruction of complex craniofacial defects provides the reconstructive surgeon with innovative options for challenging reconstructive cases. As technology advances, applications of computer-assisted reconstruction will continue to expand. © Thieme Medical Publishers.

  13. Anterior knee symptoms after S-ROM hinge implantation.

    PubMed

    Deehan, David J; Gangadharan, Rajkumar; Malviya, Ajay; Sutherland, Alasdair; Holland, James P

    2014-01-01

    To evaluate the performance of a canal filling hinge device for complex knee arthroplasty. Thirty-seven (4 primary hinge implantation and 33 revision cases) patients who had undergone arthroplasty with the S-ROM third generation hinge device for a combination of massive bone loss or ligamentous insufficiency were prospectively examined with a minimum of 5-year follow-up. Median age at surgery was 72 years (range: 43 to 87 years). Principal indications included aseptic loosening or massive osteolysis (24 cases), infection (8 cases) and periprosthetic fracture (4 cases). All patients exhibited either grade 2 (N = 12) or grade 3 (N = 25) AORI bone loss or a grade 3 medial ligament deficiency. One patient experienced implant failure (71 months), and one patient suffered late deep infection (36 months). Mean WOMAC score improved from 27 to 62. Four patients required patellar resurfacing for persistent pain. The 5-year survivorship was 86%. While the S-ROM device may offer satisfactory medium term outcome for complex end stage knee disease, we report a high rate of debilitating anterior knee symptoms.

  14. Complex functional and epithetic rehabilitation after ablation of recurrent retroauricular basal cell carcinoma – a case study

    PubMed Central

    Reich, Waldemar; Exner, Anika; Winter, Eileen; Al-Nawas, Bilal; Eckert, Alexander Walter

    2017-01-01

    The reconstruction of extended defects of the concha poses a complex challenge for plastic surgeons. In cases of subtotal ablation, an alternative method designed especially for elderly oncological patients consists of epithetic rehabilitation. However, inserting an implant-retained concha epithesis proves challenging in patients with antecedents of deep resections involving the mastoid process. In the present case study, we report on the long-term treatment course (2009–2017) of a 79-year-old male patient suffering from a recurrent basal cell carcinoma of the retroauricular region. Following tumor resection, along with lateral mastoidectomy, reconstruction, and adjuvant radiotherapy, functional and esthetic deficits primarily due to peripheral facial nerve palsy were successfully managed using a multistep procedure. The procedure was completed by inserting an implant-retained concha epithesis, resulting in improved quality of life. Due to prior lateral mastoidectomy, ultra-short implants (4 mm) were inserted, partially at atypical positions. For maintaining healthy periimplant soft tissue, aftercare comprised cold plasma treatment. This oncologic case demonstrates the therapeutic necessity of using a broad spectrum of reconstructive procedures, along with their limitations, in a critical anatomic region. Specific features include the presentation of a workflow using ultra-short implants in a compromised mastoid region. Surgeons should consider alternative implant positions in the event of any compromised mastoid process. A particular emphasis has been put on meticulous aftercare to preserve healthy periimplant soft tissues. PMID:29423354

  15. Advanced Implant-Prosthetic Rehabilitation: How to Obtain a Correct Restoration of Both Functions and Aesthetics in Patients with Complex Combined Dental and Maxillofacial Trauma: A Case Report and Topical Review of the Literature.

    PubMed

    Figliuzzi, M M; Giudice, A; Fortunato, L

    2017-01-01

    Aim . This study aims to explain the main steps that characterize the implant-prosthetic rehabilitation in complex combined dental and maxillofacial trauma. Material and Methods . A 20-year-old patient reported an extensive facial trauma which also involved the alveolar process of the maxillary bone. The patient reported a maxillofacial fracture and the loss of teeth 1.3, 1.2, 1.1, and 2.1. A "Le Fort" type 2 fracture was also reported, with the malar bone involvement. After reduction and containment of bone fractures, through appropriate mounting plates, appropriate functional and aesthetic rehabilitation of the patient were replaced thanks to a temporary removable prosthesis. After 6 months, the patient performed numerous clinical investigations, aimed at a proper planning of implant-prosthetic rehabilitation of the upper dental arch. Conclusion . With the planning of the case, as well as respecting the surrounding biological structures, the surgery of implants can be carried out with the most appropriate procedure. Lastly, new dental implants with highly bioactive surfaces have been developed, providing an excellent and rapid bone integration.

  16. Adjusting dento-alveolar morphology with orthodontic mini-implants (miniscrews). A clinical case report.

    PubMed

    Bratu, Cristina Dana; Pop, R V; Pop, Silvia-Izabella; Bratu, Em A

    2011-01-01

    Mini-implants are increasingly popular for creating skeletal anchorage in clinical orthodontics. The aim of this article is to present and discuss the clinical uses, benefits and drawbacks of the miniscrew implants used to reorder and adjust the dento-alveolar morphology of the overerupted maxillary molars. The loss of the lower premolars and molars very often leads to overeruption of the opposing maxillary teeth, combined with insufficient space for prosthetic restorations. The available treatment options are either a significant reduction of the maxillary teeth, often associated with endodontic treatment, or a complex orthodontic treatment. In the previous years, different cases of orthodontic intrusion with mini-implants were described. In this report, the authors describe a case of a young patient who needed a maxillary molar intrusion in order to get sufficient prosthetic space for an implant supported fixed restoration in the third quadrant. This treatment type preserved maximum tooth structures and allowed a successful mandibular restoration.

  17. Short Implants: New Horizon in Implant Dentistry.

    PubMed

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  18. Short Implants: New Horizon in Implant Dentistry

    PubMed Central

    Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-01-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration. PMID:27790598

  19. Simultaneous correction of post-traumatic aphakia and aniridia with the use of artificial iris and IOL implantation.

    PubMed

    Forlini, Cesare; Forlini, Matteo; Rejdak, Robert; Prokopiuk, Agata; Levkina, Oxana; Bratu, Adriana; Rossini, Paolo; Cagampang, Perfecto R; Cavallini, Gian Maria

    2013-03-01

    Combined post-traumatic aniridia and aphakia demand extensive and complex reconstructive surgery. We present our approach for simultaneous correction of this surgical situation with the use of the ArtificialIris (Dr. Schmidt Intraocularlinsen GmbH, Germany) with a foldable acrylic IOL Lentis L-313 (Oculentis, GmbH, Germany) sutured to its surface. The novelty (our first operation was on June 2010) of this surgical technique is based on the combined use of foldable (with closed haptics) IOL and Artificialiris to correct post-traumatic aniridia and aphakia. Four consecutive cases of combined post-traumatic lesions of iris and lens, corrected with complex device ArtificialIris and foldable IOL. In two cases, the compound implant was sutured to the sclera in sulcus during the penetrating keratoplasty; in another case, it was positioned through a corneal incision of about 5.0 mm with transscleral fixation, and in one patient with preserved capsular support and possibility of IOL in-the-bag implantation the ArtificialIris was placed in sulcus sutureless through a clear corneal tunnel. Maximal follow-up was 6 months. The complex device was placed firmly fixed within the sulcus, including in the eye implanted without sutures, and showed a stable and centered position without any tilt or torque. Management of post-traumatic aniridia combined with aphakia by haptic fixation of a foldable acrylic IOL on a foldable iris prosthesis appears to be a promising approach which gives the surgeon the possibility to correct a complex lesion with one procedure, which is less traumatic and faster. Existence of foldable materials, both iris and IOL, permits relatively small corneal incisions (4.0-5.0 mm). Moreover, the custom-tailored iris prosthesis gives a perfect aesthetic result.

  20. Craniofacial Prosthetic Reconstruction Using Polymethyl Methacrylate Implant: A Case Report.

    PubMed

    Simon, Paul; Mohan, Jayashree; Selvaraj, Sunantha; Saravanan, B S; Pari, Parikodaiarasan

    2014-12-01

    Large cranial defects of complex geometric shapes are challenging to reconstruct. The cranial implants has to be fabricated prior to the cranioplastic surgery. The ideal material for cranial implant has to be inert, light weight, easy to fit and adaptable to the defect, offering the best aesthetic and functional results. Here is a clinical case report of a patient who was operated for osteomyelitis in the parieto-temporal region. The defect was reconstructed with heat cure polymethylmethacrylate (PMMA). Operative closure of the defect was facilitated with ligature titanium wires with minimal prosthesis contouring. The heat cure PMMA cranial implant is a safe, easy and economic alternative with great adaptability to cranial vault defects. The cosmetic results in this patient was excellent. No post-operative complications occurred.

  1. Evolution of design considerations in complex craniofacial reconstruction using patient-specific implants.

    PubMed

    Peel, Sean; Bhatia, Satyajeet; Eggbeer, Dominic; Morris, Daniel S; Hayhurst, Caroline

    2017-06-01

    Previously published evidence has established major clinical benefits from using computer-aided design, computer-aided manufacturing, and additive manufacturing to produce patient-specific devices. These include cutting guides, drilling guides, positioning guides, and implants. However, custom devices produced using these methods are still not in routine use, particularly by the UK National Health Service. Oft-cited reasons for this slow uptake include the following: a higher up-front cost than conventionally fabricated devices, material-choice uncertainty, and a lack of long-term follow-up due to their relatively recent introduction. This article identifies a further gap in current knowledge - that of design rules, or key specification considerations for complex computer-aided design/computer-aided manufacturing/additive manufacturing devices. This research begins to address the gap by combining a detailed review of the literature with first-hand experience of interdisciplinary collaboration on five craniofacial patient case studies. In each patient case, bony lesions in the orbito-temporal region were segmented, excised, and reconstructed in the virtual environment. Three cases translated these digital plans into theatre via polymer surgical guides. Four cases utilised additive manufacturing to fabricate titanium implants. One implant was machined from polyether ether ketone. From the literature, articles with relevant abstracts were analysed to extract design considerations. In all, 19 frequently recurring design considerations were extracted from previous publications. Nine new design considerations were extracted from the case studies - on the basis of subjective clinical evaluation. These were synthesised to produce a design considerations framework to assist clinicians with prescribing and design engineers with modelling. Promising avenues for further research are proposed.

  2. Modality and risk management for orthodontic extrusion procedures in interdisciplinary treatment for generating proper bone and tissue contours for the planned implant: a case report.

    PubMed

    Maeda, Sachiko; Sasaki, Takeshi

    2015-12-01

    In adult interdisciplinary treatments with using dental implants, limited orthodontic treatment, especially orthodontic extrusion (OE), offers many benefits by both correcting teeth alignment and by contributing to the regeneration of periodontal tissues. However, orthodontic procedures carry some risks and unpredictabilities that might compromise tooth and/or periodontal tissue health. Especially in complex cases, it is difficult to decide which orthodontic treatment modalities should be combined, in what sequences they should be applied, and what their force systems and treatment times are.To achieve optimum results, some cases require two or more OEs to the same site being carried out at different times while taking the treatment effects into consideration. Such staged OE offers minimum intervention and maximum efficiency. In this case report, OE was first applied for orthodontic extraction. After bone regeneration followed by an implant placement and another surgical operation, a second OE was applied to align the inclination of an adjacent tooth. As a result, a predictable prognosis of implants as well as greatly improved esthetics and periodontal tissue health were achieved.

  3. Real-World Bioresorbable Vascular Scaffold Experience Compared With Second-Generation Metallic Drug-Eluting Stents in Complex Coronary Lesions.

    PubMed

    Okamoto, Naotaka; Ueda, Hiroshi; Yoshimura, Takahiro; Chamaria, Surbhi; Bhatheja, Samit; Vengrenyuk, Yuliya; Rabiei, Samaneh; Barrientos, Yonandy; Kapur, Vishal; Barman, Nitin; Sweeny, Joseph; Baber, Usman; Mehran, Roxana; Sharma, Samin K; Kini, Annapoorna S

    2018-04-15

    The aim of the study was to compare the acute outcomes of Absorb bioresorbable vascular scaffolds (BVS) and second-generation drug-eluting stent (DES) implantation in routine clinical practice. There is a paucity of data regarding BVS use in a real-world patient population. The study population comprised 40 consecutive patients who underwent percutaneous coronary intervention (PCI) with BVS implantation at a tertiary-care center in New York, New York between July and December of 2016. An optimal implantation technique including adequate lesion preparation, mandatory postdilation, and optical coherence tomography (OCT) imaging was used in all cases. De novo lesions treated with BVS were compared to lesions treated with DES matched by OCT calcium arc, scaffold/stent size, use of atherectomy device, and lesion postdilation. Acute lumen gain, minimal device area, malapposition, eccentricity, and symmetry index were assessed using OCT. We analyzed OCT images of 40 BVS cases and 40 matching DES cases from 35 and 40 patients, respectively. Compared to the DES group, the BVS group demonstrated similar acute lumen gain, minimal scaffold/stent area, eccentricity index, and symmetry index after PCI. There were fewer malapposed struts detected after BVS implantation; however, malapposition distance and length were not different between the groups. BVS implantation in a real-world patient population with optimal implantation technique resulted in similar stent expansion and better strut apposition compared to DES implantation.

  4. Biomechanical comparison of two different collar structured implants supporting 3-unit fixed partial denture: a 3-D FEM study.

    PubMed

    Meriç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; Ozden, Ahmet Utku

    2012-01-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone as well as in the fixture-abutment complex, in the framework and in the veneering material of 3-unit fixed partial denture (FPD). The 3-dimensional finite element analysis method was selected to evaluate the stress distribution in the system composed of 3-unit FPD supported by two different dental implant systems with two distinct collar geometries; microthread collar structure (MCS) and non-microthread collar structure (NMCS). In separate load cases, 300 N vertical, 150 N oblique and 60 N horizontal, forces were utilized to simulate the multidirectional chewing forces. Tensile and compressive stress values in the cortical and cancellous bone and von Mises stresses in the fixture-abutment complex, in the framework and veneering material, were simulated as a body and investigated separately. In the cortical bone lower stress values were found in the MCS model, when compared with NMCS. In the cancellous bone, lower stress values were observed in the NMCS model when compared with MCS. In the implant-abutment complex, highest von Mises stress values were noted in the NMCS model; however, in the framework and veneering material, highest stress values were calculated in MCS model. MCS implants when compared with NMCS implants supporting 3-unit FPDs decrease the stress values in the cortical bone and implant-abutment complex. The results of the present study will be evaluated as a base for our ongoing FEA studies focused on stress distribution around the microthread and non-microthread collar geometries with various prosthesis design.

  5. [Fatal complications following the implantation of artificial lense (author's transl)].

    PubMed

    Hamburg, A; Winkelman, J E

    1979-08-01

    The number of cataract operations with implantation of artificial lenses has been increasing in recent years. However, there is hardly any information available concerning possible serious consequences. While there are detailed reports on histopathological findings following conventional cataract operations, fatal complications of this technically complex intervention are only mentioned occasionally. There were 9 cases with serious complications in our polyclinic in 1976, and this report deals with the histopathological findings in 6 enucleated eyes. The authors warn against ill-considered decisions to perform a lens implantation.

  6. Numerical verification of two-component dental implant in the context of fatigue life for various load cases.

    PubMed

    Szajek, Krzysztof; Wierszycki, Marcin

    2016-01-01

    Dental implant designing is a complex process which considers many limitations both biological and mechanical in nature. In earlier studies, a complete procedure for improvement of two-component dental implant was proposed. However, the optimization tasks carried out required assumption on representative load case, which raised doubts on optimality for the other load cases. This paper deals with verification of the optimal design in context of fatigue life and its main goal is to answer the question if the assumed load scenario (solely horizontal occlusal load) leads to the design which is also "safe" for oblique occlussal loads regardless the angle from an implant axis. The verification is carried out with series of finite element analyses for wide spectrum of physiologically justified loads. The design of experiment methodology with full factorial technique is utilized. All computations are done in Abaqus suite. The maximal Mises stress and normalized effective stress amplitude for various load cases are discussed and compared with the assumed "safe" limit (equivalent of fatigue life for 5e6 cycles). The obtained results proof that coronial-appical load component should be taken into consideration in the two component dental implant when fatigue life is optimized. However, its influence in the analyzed case is small and does not change the fact that the fatigue life improvement is observed for all components within whole range of analyzed loads.

  7. Sound Source Localization and Speech Understanding in Complex Listening Environments by Single-sided Deaf Listeners After Cochlear Implantation.

    PubMed

    Zeitler, Daniel M; Dorman, Michael F; Natale, Sarah J; Loiselle, Louise; Yost, William A; Gifford, Rene H

    2015-09-01

    To assess improvements in sound source localization and speech understanding in complex listening environments after unilateral cochlear implantation for single-sided deafness (SSD). Nonrandomized, open, prospective case series. Tertiary referral center. Nine subjects with a unilateral cochlear implant (CI) for SSD (SSD-CI) were tested. Reference groups for the task of sound source localization included young (n = 45) and older (n = 12) normal-hearing (NH) subjects and 27 bilateral CI (BCI) subjects. Unilateral cochlear implantation. Sound source localization was tested with 13 loudspeakers in a 180 arc in front of the subject. Speech understanding was tested with the subject seated in an 8-loudspeaker sound system arrayed in a 360-degree pattern. Directionally appropriate noise, originally recorded in a restaurant, was played from each loudspeaker. Speech understanding in noise was tested using the Azbio sentence test and sound source localization quantified using root mean square error. All CI subjects showed poorer-than-normal sound source localization. SSD-CI subjects showed a bimodal distribution of scores: six subjects had scores near the mean of those obtained by BCI subjects, whereas three had scores just outside the 95th percentile of NH listeners. Speech understanding improved significantly in the restaurant environment when the signal was presented to the side of the CI. Cochlear implantation for SSD can offer improved speech understanding in complex listening environments and improved sound source localization in both children and adults. On tasks of sound source localization, SSD-CI patients typically perform as well as BCI patients and, in some cases, achieve scores at the upper boundary of normal performance.

  8. Utility of 3D printed temporal bones in pre-surgical planning for complex BoneBridge cases.

    PubMed

    Mukherjee, Payal; Cheng, Kai; Flanagan, Sean; Greenberg, Simon

    2017-08-01

    With the advent of single-sided hearing loss increasingly being treated with cochlear implantation, bone conduction implants are reserved for cases of conductive and mixed hearing loss with greater complexity. The BoneBridge (BB, MED-EL, Innsbruck, Austria) is an active fully implantable device with no attenuation of sound energy through soft tissue. However, the floating mass transducer (FMT) part of the device is very bulky, which limits insertion in complicated ears. In this study, 3D printed temporal bones of patients were used to study its utility in preoperative planning on complicated cases. Computed tomography (CT) scans of 16 ears were used to 3D print their temporal bones. Three otologists graded the use of routine preoperative planning provided by MED-EL and that of operating on the 3D printed bone of the patient. Data were collated to assess the advantage and disadvantage of the technology. There was a statistically significant benefit in using 3D printed temporal bones to plan surgery for difficult cases of BoneBridge surgery compared to the current standard. Surgeons preferred to have the printed bones in theatre to plan their drill sites and make the transition of the planning to the patient's operation more precise. 3D printing is an innovative use of technology in the use of preoperative planning for complex ear surgery. Surgical planning can be done on the patient's own anatomy which may help to decrease operating time, reduce cost, increase surgical precision and thus reduce complications.

  9. Immediate Placement of Ultrawide-Diameter Implants in Molar Sockets: Description of a Recommended Technique.

    PubMed

    Hattingh, André C; De Bruyn, Hugo; Ackermann, Andrew; Vandeweghe, Stefan

    Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with much larger socket dimensions, make it amenable to the use of ultrawide-diameter dental implants. This article describes a practical, sequenced technique that can be used predictably for immediate implant placement in maxillary and mandibular first molar sockets, using a dry skull model for clarification. This detailed description is based on the experience of more than 580 clinical cases over a 10-year period.

  10. Implant support for removable partial overdentures: a case report.

    PubMed

    Halterman, S M; Rivers, J A; Keith, J D; Nelson, D R

    1999-01-01

    Functional stability and the preservation of remaining alveolar bone are primary, and often elusive, goals when restoring the partially edentulous arch. The incorporation of dental implants for the partial support of removable prostheses offers a practical adjunct in the fulfillment of these objectives. Planning for complex courses of treatment that include dental implants requires close coordination between the surgeon and the restorative dentist. Decisions that deal with type, location, size, number of implant fixtures, and design of the prosthesis are critical. All of these areas must be discussed and established as acceptable to the patient and each clinician before the initiation of treatment. In this report, we present a course of patient treatment in which a removable partial denture is supported by natural remaining teeth in conjunction with osseointegrated implants.

  11. Resident and young physician experience with complex cataract surgery and new cataract and refractive technology: Results of the ASCRS 2016 Young Eye Surgeons survey.

    PubMed

    Schallhorn, Julie M; Ciralsky, Jessica B; Yeu, Elizabeth

    2017-05-01

    A survey was offered to attendees of the 2016 annual meeting of the American Society of Cataract and Refractive Surgery (ASCRS) as well as online to ASCRS members. Of the 429 self-identified surgeons in training or those with fewer than 5 years in practice, 83% had performed complex cataract surgery using iris expansion devices or capsular tension rings (63%) and 70% had implanted a toric intraocular lens (IOL). A minority of respondents had performed laser-assisted cataract surgery (27%) or implanted presbyopia-correcting IOLs (39%), and only half (50%) had performed laser vision correction (LVC). Comfort with complex cataract and IOL procedures improved with increasing number of cases performed until greater than 10 cases. From this we can conclude that young surgeons have adequate exposure to complex cataracts but lack experience in refractive surgery and new IOL technology. Reported surgeon confidence improved with increased experience and exposure. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Camouflage of a high-angle skeletal Class II open-bite malocclusion in an adult after mini-implant failure during treatment.

    PubMed

    Franzotti Sant'Anna, Eduardo; Carneiro da Cunha, Amanda; Paludo Brunetto, Daniel; Franzotti Sant'Anna, Claudia

    2017-03-01

    The treatment of skeletal anterior open-bite malocclusion requires complex orthodontic planning that considers its multifactorial etiology, treatment limitations, and high relapse rates. This case report illustrates a successful treatment approach for a skeletal high-angle Class II malocclusion in an adult with a severe open bite. The treatment consisted of a high-pull headgear therapy after mini-implants failure during fixed orthodontic therapy. Adequate esthetics and function were achieved. Despite its low probability, the unexpected event of mini-implant loosening during complex treatments should be considered. Therefore, classic orthodontic mechanics should be established, especially when treating patients for whom invasive procedures such as miniplates or orthognathic surgery are not available options. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  13. Case acceptance: no random acts allowed.

    PubMed

    McAnally, James

    2009-12-01

    Consider implementing a case acceptance system in your office to fully utilize your hard-earned clinical skills, and to experience the professional rewards that come with serving more patients at a higher level. Doctors who are willing to commit the time and resources necessary to improving case acceptance will increase the number of implant cases entering the treatment phase--cases that run the gamut of complexity and support fees commensurate with their skills!

  14. Prospective study on cranioplasty with individual carbon fiber reinforced polymer (CFRP) implants produced by means of stereolithography.

    PubMed

    Wurm, Gabriele; Tomancok, Berndt; Holl, Kurt; Trenkler, Johannes

    2004-12-01

    The aim of this study was to evaluate the value of carbon fiber reinforced polymer (CFRP) cranial implants produced by means of 3-dimensional (3D) stereolithography (SL) and template modeling for reconstructions of complex or extensive cranial defects. A series of 41 cranioplasties with individual CFRP implants was performed in 37 patients between April 1996 and November 2002. Only patients with complex and/or large cranial defects were included, most of them having extended scarring or dural calcification and poor quality of the overlying soft-tissue cover after infection or multiple preceding operations. Involvement of frontal sinus, a known risk factor for complications after cranioplasty, was the case in 21 patients (51.2%). A computer-based 3D model of the skull with the bony defect was generated by means of stereolithography after acquisition, evaluation and transfer of the patient's helical computed tomography (CT) data. A wax template of the defect that was used to design the individual prosthesis-shape was invested in dental stone. Then, the cranial implant was fabricated out of CFRP by loosen mold. Reconstruction of defects measuring up to 17 x 9 cm was performed. The intra-operative fit of the implants was excellent in 36 (87.8%), good in 1 (2.4%), and fair in 4 (9.8%) of the cases. Problems of implant fit occurred because of extended scarring and poor quality of soft-tissue cover. Adverse reactions were observed in 5 patients (1 subdural, 1 subcutaneous hematoma, 2 infections, 1 allergic reaction). Excellent contours and a solid stable reconstruction have been maintained in 30 out of 35 remaining plates (mean follow-up 3.6 years). No adverse effects concerning postoperative imaging, the accuracy of electroencephalograms and radiation therapy have been observed. The authors believe that this relatively new technique represents an advance in the management of complex and large cranial defects, but seems less suitable for simple defects because of cost-intensive techniques. Because of the high mechanical strength, biocompatibility, innovative design, and especially radiolucency, CFRP implants should, however, be considered in smaller defects if further imaging investigations or irradiation therapies are necessary.

  15. Low pacemaker incidence with continuous-sutured valves: a retrospective analysis.

    PubMed

    Niclauss, Lars; Delay, Dominique; Pfister, Raymond; Colombier, Sebastien; Kirsch, Matthias; Prêtre, René

    2017-06-01

    Background Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p < 0.001), complex prosthetic endocarditis ( p = 0.01), and complex redo ( p < 0.001) were associated with permanent pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation.

  16. 3D Printed, Customized Cranial Implant for Surgical Planning

    NASA Astrophysics Data System (ADS)

    Bogu, Venkata Phanindra; Ravi Kumar, Yennam; Asit Kumar, Khanra

    2018-06-01

    The main objective of the present work is to model cranial implant and printed in FDM machine (printer model used: mojo). Actually this is peculiar case and the skull has been damaged in frontal, parietal and temporal regions and a small portion of frontal region damaged away from saggital plane, complexity is to fill this frontal region with proper curvature. The Patient CT-data (Number of slices was 381 and thickness of each slice is 0.488 mm) was processed in mimics14.1 software, mimics file was sent to 3-matic software and calculated thickness of skull at different sections where cranial implant is needed then corrected the edges of cranial implant to overcome CSF (cerebrospinal fluid) leakage and proper fitting. Finally the implant average thickness is decided as 2.5 mm and printed in FDM machine with ABS plastic.

  17. 3D Printed, Customized Cranial Implant for Surgical Planning

    NASA Astrophysics Data System (ADS)

    Bogu, Venkata Phanindra; Ravi Kumar, Yennam; Asit Kumar, Khanra

    2016-06-01

    The main objective of the present work is to model cranial implant and printed in FDM machine (printer model used: mojo). Actually this is peculiar case and the skull has been damaged in frontal, parietal and temporal regions and a small portion of frontal region damaged away from saggital plane, complexity is to fill this frontal region with proper curvature. The Patient CT-data (Number of slices was 381 and thickness of each slice is 0.488 mm) was processed in mimics14.1 software, mimics file was sent to 3-matic software and calculated thickness of skull at different sections where cranial implant is needed then corrected the edges of cranial implant to overcome CSF (cerebrospinal fluid) leakage and proper fitting. Finally the implant average thickness is decided as 2.5 mm and printed in FDM machine with ABS plastic.

  18. Numerical FEM modeling in dental implantology

    NASA Astrophysics Data System (ADS)

    Roateşi, Iulia; Roateşi, Simona

    2016-06-01

    This paper is devoted to a numerical approach of the stress and displacement calculation of a system made up of dental implant, ceramic crown and surrounding bone. This is the simulation of a clinical situation involving both biological - the bone tissue, and non-biological - the implant and the crown, materials. On the other hand this problem deals with quite fine technical structure details - the threads, tapers, etc with a great impact in masticatory force transmission. Modeling the contact between the implant and the bone tissue is important to a proper bone-implant interface model and implant design. The authors proposed a three-dimensional numerical model to assess the biomechanical behaviour of this complex structure in order to evaluate its stability by determining the risk zones. A comparison between this numerical analysis and clinical cases is performed and a good agreement is obtained.

  19. Is The Periapical lesion a Risk For Periimplantitis? (A review)

    PubMed Central

    Esfahrood, Z. Rezaei; Kadkhodazadeh, M.; Amid, R.; Rokn, AR.

    2012-01-01

    Conventional implant dentistry has been limited to healed edentulous ridges with adequate bone. Predictable success rates resulted in using dental implants in compromised situations such as insertion into old infected sites or near to pathological areas. There is significant data about marginal bone loss and lack of osseointegration around the neck of implants. However, the data about peri apical implant bone loss is really rare. An electronic search was carried in PubMed regarding articles in the time period from 1980 to 2011. Subsequent manual search was performed included all animal and human case series and clinical trials. Reported success rates and treatment options were calculated in a systematic manner. There is conflicted data showing a relatively accepted success of implantation immediately after removal of infection directly or indirectly in contact with the apical portion of the implants. However, some complications may happen that must be managed. The available data about the periapical implant pathologies is relatively inadequate. However, concluded data represents some clinical comments in order to reduce the complexities. PMID:23066482

  20. Is The Periapical lesion a Risk For Periimplantitis? (A review).

    PubMed

    Esfahrood, Z Rezaei; Kadkhodazadeh, M; Amid, R; Rokn, Ar

    2012-01-01

    Conventional implant dentistry has been limited to healed edentulous ridges with adequate bone. Predictable success rates resulted in using dental implants in compromised situations such as insertion into old infected sites or near to pathological areas. There is significant data about marginal bone loss and lack of osseointegration around the neck of implants. However, the data about peri apical implant bone loss is really rare.An electronic search was carried in PubMed regarding articles in the time period from 1980 to 2011. Subsequent manual search was performed included all animal and human case series and clinical trials. Reported success rates and treatment options were calculated in a systematic manner.There is conflicted data showing a relatively accepted success of implantation immediately after removal of infection directly or indirectly in contact with the apical portion of the implants. However, some complications may happen that must be managed.The available data about the periapical implant pathologies is relatively inadequate. However, concluded data represents some clinical comments in order to reduce the complexities.

  1. Improving surgical results in complex nerve anatomy during implantation of selective upper airway stimulation.

    PubMed

    Zhu, Zhaojun; Hofauer, Benedikt; Heiser, Clemens

    2018-06-01

    The following report presents a case of two late embedded hypoglossus branches during implantation of an upper airway stimulation device that caused a mixed activation of the tongue when included in the stimulation cuff. In the end, correct cuff placement could be achieved by careful examination of the hypoglossal nerve anatomy, precise nerve dissection, tongue motion analysis and intraoperative nerve monitoring. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. [Rehabilitation of a periodontally compromised dentition with implant-supported zirconia bridges. Case report].

    PubMed

    Balmer, Sacha; Mericske-Stern, Regina

    2009-01-01

    Clinical aspects of reconstruction with fix prosthesis and dental implants in a patient with a history of periodontitis is shown. A successful stabilization and rehabilitation of the periodontally involved dentition can be achieved with tooth-worn crown and bridge reconstructions. From a functional and aesthetic point of view the result may not be satisfying due to mobility and overlength of the teeth and open approximal spaces. Today, dentist and patient have often to weigh if teeth shall be maintained or replaced by dental implants. Thereby, both must be aware of the fact that in complex cases long-term success and aesthetic outcome may be difficult to predict. An intense discussion with the patient on his expectations, invasive treatment, risks with regard to biologic and prosthetic aspects is mandatory and must be based on the best scientific evidence available. The present case report shows different considerations and describes a radical solution which meets the patient's needs and is based on modern CAD-CAM technology.

  3. [Dental implantation and soft tissue augmentation after ridge preservation in a molar site: a case report].

    PubMed

    Zhao, L P; Zhan, Y L; Hu, W J; Wang, H J; Wei, Y P; Zhen, M; Xu, T; Liu, Y S

    2016-12-18

    For ideal implant rehabilitation, an adequate bone volume, optical implant position, and stable and healthy soft tissue are required. The reduction of alveolar bone and changes in its morphology subsequent to tooth extraction will result in insufficient amount of bone and adversely affect the ability to optimally place dental implants in edentulous sites. Preservation of alveolar bone volume through ridge preservation has been demonstrated to reduce the vertical and horizontal contraction of the alveolar bone crest after tooth extraction and reduce the need for additional bone augmentation procedures during implant placement. In this case, a patient presented with a mandible molar of severe periodontal disease, the tooth was removed as atraumatically as possible and the graft material of Bio-Oss was loosely placed in the alveolar socket without condensation and covered with Bio-Gide to reconstruct the defects of the alveolar ridge. Six months later, there were sufficient height and width of the alveolar ridge for the dental implant, avoiding the need of additional bone augmentation and reducing the complexity and unpredictability of the implant surgery. Soft tissue defects, such as gingival and connective tissue, played crucial roles in long-term implant success. Peri-implant plastic surgery facilitated development of healthy peri-implant structure able to withstand occlusal forces and mucogingival stress. Six months after the implant surgery, the keratinized gingiva was absent in the buccal of the implant and the vestibular groove was a little shallow. The free gingival graft technique was used to solve the vestibulum oris groove supersulcus and the absence of keratinized gingiva around the implant. The deepening of vestibular groove and broadening of keratinized gingiva were conducive to the long-term health and stability of the tissue surrounding the implant. Implant installation and prosthetic restoration showed favorable outcome after six months.

  4. Inappropriate Implantable Cardioverter-Defibrillator Shock from QRS Double Counting in the Setting of Hyperkalemia.

    PubMed

    Dadlani, Akash; Dukes, Jonathan W; Badhwar, Nitish

    2016-03-01

    This case shows the complexity of arrhythmia management in patients with implantable cardioverter-defibrillators (ICDs) who present with hyperkalemia. In order to prevent inappropriate ICD shock, consideration should be given to the suspension of ICD therapies while intensive care treatment of extreme electrolyte derangements is being pursued. Patients in these setting should be closely monitored until their electrocardiograms have normalized, after which the device can safely be reactivated. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Predictability of short implants (< 10 mm) as a treatment option for the rehabilitation of atrophic maxillae. A systematic review

    PubMed Central

    García-Sala-Bonmatí, Fernando; Martínez-González, Amparo; García-Dalmau, Carlos; Mañes-Ferrer, José-Félix; Brotons-Oliver, Alejandro

    2016-01-01

    Background Short implants (< 10 mm) are one of the treatment options available in cases of limited vertical bone. A purpose of this paper is to evaluate the predictability of short implants as an alternative to technically molthough such implants are now widely used, there is controversy regarding their clinical reliability. There complex treatments in patients with atrophic maxillae, based on a systematic review of the literature and the analysis of the implant survival rates, changes in peri-implant bone level, and associated complications. It is postulated that short implants offer clinical results similar to those of longer implants. Material and Methods A Medline-PubMed search was made covering the period between January 2004 and December 2014 (both included). Studies in English published in indexed journals, involving at least 20 implants and with a follow-up period of at least 12 months were considered. A manual search in four high impact journals was also conducted. Results A total of 37 studies meeting the inclusion criteria were included in this review. 9792 implants placed in over 5000 patients were analyzed. Conclusions Based on the results of this review, short implants are seen to offer clinical results in terms of survival, bone loss and complications similar to those of longer implants. Key words:Survival rate, clinical results, dental implants, oral implants, short implants, short lengt PMID:26946199

  6. Dislocation and spontaneous reduction of the femoral implant against the femoral neck in an infected metal on metal hip resurfacing with complex collection.

    PubMed

    Tins, Bernhard

    2011-07-01

    Metal on metal resurfacing hip implants are known to have complications unique to this type of implant. The case presented adds a further previously not described complication, the dislocation and spontaneous reduction of the pin of the femoral component against the femoral neck. The radiographic and CT findings are demonstrated. The dislocation was aided by bone loss due to an infection with a large periarticular collection. Periarticular collections in hip resurfacings are often due to a hypersensitivity type reaction to metal debris. However in the case presented it was due to infection. MRI was not able to discern the infection from a sterile collection. CT demonstrated bone loss and periosteal reaction suggestive of infection. In addition calcification of the pseudocapsule was seen, this is not a recognized feature of sterile collections. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  7. Scanning electron microscopy (SEM) and X-ray dispersive spectrometry evaluation of direct laser metal sintering surface and human bone interface: a case series.

    PubMed

    Mangano, Carlo; Piattelli, Adriano; Raspanti, Mario; Mangano, Francesco; Cassoni, Alessandra; Iezzi, Giovanna; Shibli, Jamil Awad

    2011-01-01

    Recent studies have shown that direct laser metal sintering (DLMS) produces structures with complex geometry and consequently that allow better osteoconductive properties. The aim of this patient report was to evaluate the early bone response to DLMS implant surface retrieved from human jaws. Four experimental DLMS implants were inserted in the posterior mandible of four patients during conventional dental implant surgery. After 8 weeks, the micro-implants and the surrounding tissue were removed and prepared for scanning electron microscopy (SEM) and histomorphometric analysis to evaluate the bone-implant interface. The SEM and EDX evaluations showed a newly formed tissue composed of calcium and phosphorus. The bone-to-implant contact presented a mean of 60.5 ± 11.6%. Within the limits of this patient report, data suggest that the DLMS surfaces presented a close contact with the human bone after a healing period of 8 weeks.

  8. Surface characteristics of clinically used dental implant screws

    NASA Astrophysics Data System (ADS)

    Han, Myung-Ju; Choe, Han-Cheol; Chung, Chae-Heon

    2005-12-01

    Surface alteration of implant screws after function may be associated with mechanicalffailure. This type of metal fatigue appears to be the most common cause of structural failure. The purpose of this study was to evaluate surface alteration of implant screws after function through an examination of used and unused implant screws via scanning electron microscopy (SEM). In this study, abutment screws (Steri-oss, 3i, USA), gold retaining screws (3i, USA), and titanium retaining screws (3i, USA) were retrieved from patients, New, unused abutment, and retaining screws were prepared for a control group. Each of the old, used screws was retrieved with a screwdriver. The retrieved implant complex of a Steri-oss system was also prepared for this study. SEM investigation and energy dispersive spectroscopy (EDS) analysis of the abutment and retaining screws were then performed, as well as SEM investigation of a cross-sectioned sample of the retrieved implant complex in the case of new, unused implant screws, as-manufactured circumferential grooves were regularly examined and screw threads were sharply maintained. Before ultrasonic cleansing of old, used implant screws, there was a large amount of debris accumulation and corrosion products. After ultrasonic cleansing of old, used implant screws, circumferential grooves were examined were found to be randomly deepened and scratching increased. Also, dull screw fhreads were observed. More surface alterations after function were observed in titanium screws than in gold screws. Furthermore, more surface alteration was observed when the screws were retrieved with a driver than without a driver. These surface alterations after function may result in screw instability. Regular cleansing and exchange of screws is therefore recommended. We also recommend the use of gold screws over titanium screws, and careful manipulation of the driver.

  9. Facial and occlusal esthetic improvements of an adult skeletal Class III malocclusion using surgical, orthodontic, and implant treatment

    PubMed Central

    de Almeida Cardoso, Mauricio; de Avila, Erica Dorigatti; Guedes, Fabio Pinto; Battilani Filho, Valter Antonio Ban; Capelozza Filho, Leopoldino; Correa, Marcio Aurelio; Nary Filho, Hugo

    2016-01-01

    The aim of this clinical report is to describe the complex treatment of an adult Class III malocclusion patient who was disappointed with the outcome of a previous oral rehabilitation. Interdisciplinary treatment planning was performed with a primary indication for implant removal because of marginal bone loss and gingival recession, followed by orthodontic and surgical procedures to correct the esthetics and skeletal malocclusion. The comprehensive treatment approach included: (1) implant removal in the area of the central incisors; (2) combined orthodontic decompensation with mesial displacement and forced extrusion of the lateral incisors; (3) extraction of the lateral incisors and placement of new implants corresponding to the central incisors, which received provisional crowns; (4) orthognathic surgery for maxillary advancement to improve occlusal and facial relationships; and finally, (5) orthodontic refinement followed by definitive prosthetic rehabilitation of the maxillary central incisors and reshaping of the adjacent teeth. At the three-year follow-up, clinical and radiographic examinations showed successful replacement of the central incisors and improved skeletal and esthetic appearances. Moreover, a Class II molar relationship was obtained with an ideal overbite, overjet, and intercuspation. In conclusion, we report the successful esthetic anterior rehabilitation of a complex case in which interdisciplinary treatment planning improved facial harmony, provided gingival architecture with sufficient width and thickness, and improved smile esthetics, resulting in enhanced patient comfort and satisfaction. This clinical case report might be useful to improve facial esthetics and occlusion in patients with dentoalveolar and skeletal defects. PMID:26877982

  10. [Breast reconstruction: autologous tissue versus implant].

    PubMed

    Plogmeier, K; Handstein, S; Schneider, W

    1998-01-01

    Modified radical mastectomy remains the standard for treatment of breast cancer. Women faced with the diagnosis of breast cancer often find it difficult to cope with the arousing emotions. Fear of death or cancer recurrence and a perceived loss of femininity often coexists with the desire for a return to normality and wholeness. For women seeking breast reconstruction various techniques have been developed. Two different ways for breast reconstruction have become a standard. One way is the reconstruction by tissue expansion or transposing locally available tissue with the use of implants. The other way is the reconstruction of the breast without using any implants with the Latissimus dorsi flap or the TRAM flap. We performed 291 breast reconstructions. In 125 women available tissue and an implant was used. The Latissimus dorsi flap was used in 57 cases and 109 TRAM flaps either pedicled or as a microvascular flap were performed. Using expanders we found a perforation of the device in 2 cases. After using implants there were capsular contracture in 2 cases and in 1 case we had an infection. Using autologous tissue we had 2 partial flap necrosis, 4 hematomas, and 4 prolonged healings. There was no complete flap necrosis. Breast reconstruction using autologous tissue i.e. the TRAM flap is supposed to be a standard technique. Microsurgical transplantation of the TRAM flap shows almost no morbidity of the donor site area. Autologous tissue follows the changes of the body like weight gain or reduction to a certain extend and shows neither capsular contracture nor other implant associated side effects. Women get the impression that the TRAM flap is like soft tissue to the touch and not like a foreign body. The aesthetic results were in all cases superior sometimes needing minor secondary correction and mostly shaping of the nippel-areola complex. All patients were pleased with the result.

  11. Cardiac pacemaker battery discharge after external electrical cardioversion for broad QRS Complex Tachycardia.

    PubMed

    Annamaria, Martino; Andrea, Scapigliati; Michela, Casella; Tommaso, Sanna; Gemma, Pelargonio; Antonio, Dello Russo; Roberto, Zamparelli; Stefano, De Paulis; Fulvio, Bellocci; Rocco, Schiavello

    2008-08-01

    External electrical cardioversion or defibrillation may be necessary in patients with implanted cardiac pacemaker (PM) or implantable cardioverter defibrillator (ICD). Sudden discharge of high electrical energy employed in direct current (DC) transthoracic countershock may damage the PM/ICD system resulting in a series of possible device malfunctions. For this reason, when defibrillation or cardioversion must be attempted in a patient with a PM or ICD, some precautions should be taken, particularly in PM dependent patients, in order to prevent damage to the device. We report the case of a 76-year-old woman with a dual chamber PM implanted in the right subclavicular region, who received two consecutive transthoracic DC shocks to treat haemodynamically unstable broad QRS complex tachycardia after cardiac surgery performed with a standard sternotomic approach. Because of the sternal wound and thoracic drainage tubes together with the severe clinical compromise, the anterior paddle was positioned near the pulse generator. At the following PM test, a complete battery discharge was detected.

  12. Dental implants in medically complex patients-a retrospective study.

    PubMed

    Manor, Yifat; Simon, Roy; Haim, Doron; Garfunkel, Adi; Moses, Ofer

    2017-03-01

    Dental implant insertion for oral rehabilitation is a worldwide procedure for healthy and medically compromised patients. The impact of systemic disease risks on the outcome of implant therapy is unclear, since there are few if any published randomized controlled trials (RCTs). The objective of this study is to investigate the rate of complications and failures following dental implantation in medically compromised patients in order to elucidate risk factors and prevent them. A retrospective cohort study was conducted from patient files treated with dental implantation between the years 2008-2014. The study group consisted of medically complex patients while the control group consisted of healthy patients. Preoperative, intraoperative, and post operative clinical details were retrieved from patients' files. The survival rate and the success rate of the dental implants were evaluated clinically and radiographically. A total of 204 patients (1003 dental implants) were included in the research, in the study group, 93 patients with 528 dental implants and in the control group, 111 patients with 475 dental implants. No significant differences were found between the groups regarding implant failures or complications. The failure rate of dental implants among the patients was 11.8 % in the study group and 16.2 % in the control group (P = 0.04). It was found that patients with a higher number of implants (mean 6.8) had failures compared with patients with a lower number of implants (mean 4.2) regardless of their health status (P < 0.01). We found a similar rate of failure and complications of dental implantation in medically complex patients and in healthy patients. Medically complex patients can undergo dental implantation. There are similar rates of complications and failures of dental implants in medically complex patients and in healthy patients.

  13. Reconstruction of Thoracic Spine Using a Personalized 3D-Printed Vertebral Body in Adolescent with T9 Primary Bone Tumor.

    PubMed

    Choy, Wen Jie; Mobbs, Ralph J; Wilcox, Ben; Phan, Steven; Phan, Kevin; Sutterlin, Chester E

    2017-09-01

    Neurosurgery and spine surgery have the potential to benefit from the use of 3-dimensional printing (3DP) technology due to complex anatomic considerations and the delicate nature of surrounding structures. We report a procedure that uses a 3D-printed titanium T9 vertebral body implant post T9 vertebrectomy for a primary bone tumor. A 14-year-old female presented with progressive kyphoscoliosis and a pathologic fracture of the T9 vertebra with sagittal and coronal deformity due to a destructive primary bone tumor. Surgical resection and reconstruction was performed in combination with a 3D-printed, patient-specific implant. Custom design features included porous titanium end plates, corrective angulation of the implant to restore sagittal balance, and pedicle screw holes in the 3D implant to assist with insertion of the device. In addition, attachment of the anterior column construct to the posterior pedicle screw construct was possible due to the customized features of the patient-specific implant. An advantage of 3DP is the ability to manufacture patient-specific implants, as in the current case example. Additionally, the use of 3DP has been able to reduce operative time significantly. Surgical procedures can be preplanned using 3DP patient-specific models. Surgeons can train before performing complex procedures, which enhances their presurgical planning in order to maximize patient outcomes. When considering implants and prostheses, the use of 3DP allows a superior anatomic fit for the patient, with the potential to improve restoration of anatomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Long-term Survival of Straumann Dental Implants with TPS Surfaces: A Retrospective Study with a Follow-up of 12 to 23 Years.

    PubMed

    Becker, Stephan T; Beck-Broichsitter, Benedicta E; Rossmann, Christian M; Behrens, Eleonore; Jochens, Arne; Wiltfang, Jörg

    2016-06-01

    The aim of this study was to evaluate the long-term dental implant survival rates of Straumann dental implants in a university hospital environment over 12 to 23 years. A total of 388 Straumann dental implants with titanium-sprayed surfaces (TPS) were inserted in 92 patients between 1988 and 1999 in the Department of Oral and Maxillofacial Surgery of the University Hospital Schleswig-Holstein in Kiel, and they were reevaluated with standardized clinical and radiological exams. Kaplan-Meier analyses were performed for individual factors. Cox proportional hazard regression analysis was used to detect the factors influencing long-term implant failure. The long-term implant survival rate was 88.03% after an observation time of 12.2 to 23.5 years. Cox regression revealed statistically significant influences of the International Team for Implantology (ITI) implantation type (p = .00354) and tobacco smoking (p = .01264) on implant failure. A proportion 82.8% of the patients with implant losses had a medical history of periodontitis. Peri-implantitis was diagnosed in 9.7% of the remaining implants in the long-term survey. This study emphasized the long-term rehabilitation capabilities of Straumann dental implants in complex cases. The survival rates after several years constitute important information for patients, as well as for clinicians, in deciding about different concepts of tooth replacement. Patient-related and technical factors - determined before implant placement - could help to predict the risk of implant loss. © 2015 Wiley Periodicals, Inc.

  15. Autologous chondrocyte implantation for cartilage injury treatment in Chiang Mai University Hospital: a case report.

    PubMed

    Wongtriratanachai, Prasit; Pruksakorn, Dumnoensun; Pothacharoen, Peraphan; Nimkingratana, Puwapong; Pattamapaspong, Nuttaya; Phornphutkul, Chanakarn; Setsitthakun, Sasiwariya; Fongsatitkul, Ladda; Phrompaet, Sureeporn

    2013-11-01

    Autologous chondrocyte implantation (ACI) has become one of the standard procedures for articular cartilage defect treatment. This technique provides a promising result. However the procedural process requires an approach of several steps from multidisciplinary teams. Although the success of this procedure has been reported from Srinakharinvirot University since 2007, the application of ACI is still limited in Thailand due to the complexity of processes and stringent quality control. This report is to present the first case of the cartilage defect treatment using the first generation-ACI under Chiang Mai University's (CMU) own facility and Ethics Committee. This paper also reviews the process of biotechnology procedures, patient selection, surgical, and rehabilitation techniques. The success of the first case is an important milestone for the further development of the CMU Human Translational Research Laboratory in near future.

  16. Evaluation of the Alteration of Occlusal Distribution in Unilateral Free-End and Intermediate Missing Cases.

    PubMed

    Kon, Kazuhiro; Shiota, Makoto; Sakuyama, Aoi; Ozeki, Maho; Kozuma, Wataru; Kawakami, Sawako; Kasugai, Shohei

    2017-02-01

    The present study aimed to evaluate the effect of implant prostheses on the occlusal force and area as well as the distribution of occlusal loading in unilateral free-end and intermediate missing cases. Fourteen healthy subjects (7 free-end missing cases in the first and second molars and 7 intermediate missing cases in the first molar region) were included. Six months after the implant prosthesis was placed, an occlusal evaluation was performed with or without the implant superstructure by using Dental Prescale film and an occluder device. In free-end missing cases, the total occlusal force and area, implant-side occlusal force and area, and implant-side occlusal force and area of the residual natural teeth were significantly affected by the implant prostheses. In intermediate missing cases, the implant-side occlusal force of the residual natural teeth was significantly affected by the implant prostheses. In free-end missing cases, the proportions of implant-side occlusal force, non-implant-side occlusal force, and implant-side occlusal force of the residual natural teeth relative to the total occlusal force were significantly affected by the implant prostheses. In the intermediate missing cases, the proportion of the implant-side occlusal force of the residual natural teeth relative to the total occlusal force was significantly affected by the implant prostheses. The proportion of the occlusal area was also significantly affected. In free-end missing cases, implant prostheses significantly increased the occlusal force and area, which resulted in the proper occlusal distribution. In intermediate missing cases, an implant prosthesis may only improve the same-side occlusal loading of the natural teeth.

  17. A Case Series of Rapid Prototyping and Intraoperative Imaging in Orbital Reconstruction

    PubMed Central

    Lim, Christopher G.T.; Campbell, Duncan I.; Cook, Nicholas; Erasmus, Jason

    2014-01-01

    In Christchurch Hospital, rapid prototyping (RP) and intraoperative imaging are the standard of care in orbital trauma and has been used since February 2013. RP allows the fabrication of an anatomical model to visualize complex anatomical structures which is dimensionally accurate and cost effective. This assists diagnosis, planning, and preoperative implant adaptation for orbital reconstruction. Intraoperative imaging involves a computed tomography scan during surgery to evaluate surgical implants and restored anatomy and allows the clinician to correct errors in implant positioning that may occur during the same procedure. This article aims to demonstrate the potential clinical and cost saving benefits when both these technologies are used in orbital reconstruction which minimize the need for revision surgery. PMID:26000080

  18. A case series of rapid prototyping and intraoperative imaging in orbital reconstruction.

    PubMed

    Lim, Christopher G T; Campbell, Duncan I; Cook, Nicholas; Erasmus, Jason

    2015-06-01

    In Christchurch Hospital, rapid prototyping (RP) and intraoperative imaging are the standard of care in orbital trauma and has been used since February 2013. RP allows the fabrication of an anatomical model to visualize complex anatomical structures which is dimensionally accurate and cost effective. This assists diagnosis, planning, and preoperative implant adaptation for orbital reconstruction. Intraoperative imaging involves a computed tomography scan during surgery to evaluate surgical implants and restored anatomy and allows the clinician to correct errors in implant positioning that may occur during the same procedure. This article aims to demonstrate the potential clinical and cost saving benefits when both these technologies are used in orbital reconstruction which minimize the need for revision surgery.

  19. Dental implant imaging: TeraRecon's Dental 3D Cone Beam Computed Tomography System.

    PubMed

    Garg, Arun K

    2007-06-01

    Early in the development of implant technology, conventional dental imaging techniques were limited for evaluating the patient for implant surgery. During the treatment-planning phase, the recipient bed is routinely assessed by visual examination and palpation, as well as by periapical and panoramic radiology. These two imaging modalities provide a two-dimensional image of the mesiodistal and occlusoapical dimensions of the edentulous regions where the implants might be placed. When adequate occlusoapical bone height is available for endosteal implants, the buccolingual width and angulation of the available bone are the most important criteria for implant selection and success. However, neither buccolingual width nor angulation can be visualized on most traditional radiographs. Although clinical examination and traditional radiographs may be adequate for patients with wide residual ridges that exhibit sufficient bone crestal to the mandibular nerve and maxillary sinus, these methods do not allow for the precise measurement of the buccolingual dimension of the bone or assessment of the location of unanticipated undercuts. Because of these concerns, it is necessary to view the recipient site in a plane through the arch of the maxilla or mandible in the region of the proposed implants. Implant surgeons soon recognized that, for the optimum placement of implants, cross-sectional views of the maxilla and mandible are the ideal means for providing necessary preoperative information. For complex cases where multiple implants are required or where anatomical measurements are crucial, but also increasingly for more routine cases, more and more clinicians are recommending CT scan imaging procedure such as that offered by TeraRecon's Dental CBCT system. Because of its ability to reconstruct a fully three-dimensional model of the maxilla and mandible, CBCT provides a highly sophisticated format for precisely defining the jaw structure and locating critical anatomic structures. CBCT scans, in conjunction with software that renders immediate treatment plans using the most real and accurate information, provide the most precise radiographic modality currently available for the evaluation of patients for oral implants.

  20. Aesthetic Rehabilitation of a Complicated Crown-Root Fracture of the Maxillary Incisor: Combination of Orthodontic and Implant Treatment

    PubMed Central

    de Avila, Érica Dorigatti; de Molon, Rafael Scaf; Cardoso, Mauricio de Almeida; Capelozza Filho, Leopoldino; Campos Velo, Marilia Mattar de Amoêdo; Mollo, Francisco de Assis; Borelli Barros, Luiz Antonio

    2014-01-01

    The aim of this paper is to present a complex rehabilitation, of fractured tooth, with implants in anterior region considering the orthodontics extrusion to clinical success. At 7 years old, the patient fractured the maxillary left central incisor and the dentist did a crown with the fragment. Twenty years later, the patient was referred to a dental clinic for orthodontic treatment, with the chief complaint related to an accentuated deep bite, and a professional started an orthodontic treatment. After sixteen months of orthodontic treatment, tooth 21 fractured. The treatment plan included an orthodontic extrusion of tooth 21 and implant placement. This case has been followed up and the clinical and radiographic examinations show excellence esthetic results and satisfaction of patient. The forced extrusion can be a viable treatment option in the management of crown root fracture of an anterior tooth to gain bone in a vertical direction. This case emphasizes that to achieve the esthetic result a multidisciplinary approach is necessary. PMID:24872900

  1. Chronic post-operative iris prosthesis endophthalmitis in a patient with traumatic aniridia: a case report.

    PubMed

    Firl, Kevin C; Montezuma, Sandra R

    2016-11-09

    Post-operative endophthalmitis is a serious complication of intraocular surgery which may present acutely or chronically. Chronic post-operative endophthalmitis is characterized by decreased visual acuity, mild pain, and low-grade uveitis several weeks or months after intraocular surgery which may be responsive to corticosteroids, but recur upon tapering. Low virulence organisms such as Propionibacterium acnes are the most common culprit organisms, and treatment most often consists of both intravitreal antibiotic injections and surgery. Aniridia is a condition defined by total or partial loss of the iris and leads to decreased visual quality marked by glare and photophobia. Treatment of complex or severe cases of traumatic aniridia in which surgical repair is difficult may consist of implantation of iris prostheses, devices designed to reduce symptoms of aniridia. Though chronic, post-operative endophthalmitis has been associated with most intraocular surgeries including intraocular lens implantation after cataract removal, it has never been described in a patient with an iris prosthesis. In this case report, we describe the case of a 49 year old, male construction worker with traumatic aniridia who experienced chronic, recurrent low-grade intraocular inflammation and irritation for months after implantation of the Ophtec 311 prosthetic iris. Symptoms and signs of inflammation improved temporarily with sub-Tenon's capsule triamcinolone injections. Ultimately after more than 2 post-operative years, the iris prosthesis was explanted, and intravitreal cultures showed P. acnes growth after 5 days. Intravitreal antibiotics treated the infection successfully. To our knowledge, this is the first reported case of chronic, post-operative endophthalmitis in a patient with an iris prosthesis. Chronic, post-operative endophthalmitis may be a difficult to identify in the context of traumatic aniridia and iris prosthesis implantation due to other potential etiologies of chronic intraocular inflammation such as implant-induced chafing. Clinicians should suspect chronic, post-operative endophthalmitis in any case of recurrent, low-grade intraocular inflammation.

  2. Minimally invasive surgical implantation of left ventricular epicardial leads for ventricular resynchronization using video-assisted thoracoscopy.

    PubMed

    Fernández, Angel L; García-Bengochea, José B; Ledo, Ramiro; Vega, Marino; Amaro, Antonio; Alvarez, Julián; Rubio, José; Sierra, Juan; Sánchez, Daniel

    2004-04-01

    Cardiac resynchronization via left ventricular or biventricular pacing is an option for selected patients with ventricular systolic dysfunction and widened QRS complex. Stimulation through a coronary vein is the technique of choice for left ventricular pacing, but this approach results in a failure rate of approximately 8%. We describe our initial experience with minimally invasive surgical implantation of left ventricular epicardial leads using video-assisted thoracoscopy. A total of 14 patients with congestive heart failure, NYHA functional class 3.2 (0.6) and mean ejection fraction 22.9 (6.8)% were included in this study. Left bundle branch block, QRS complex >140 ms and abnormal septal motion were observed in all cases. Epicardial leads were implanted on the left ventricular free wall under general anesthesia using video-assisted thoracoscopic surgery. Lead implantation was successful in 13 patients. Conversion to a small thoracotomy was necessary in one patient. All patients were extubated in the operating room. None of the patients died during their hospital stay. Follow-up showed reversal of ventricular asynchrony and significant improvement in ejection fraction and functional class. Minimally invasive surgery for ventricular resynchronization using video-assisted thoracoscopy in selected patients is a safe procedure that makes it possible to choose the best site for lead implantation and provides adequate short- and medium-term stimulation.

  3. Perioprosthetic and Implant-Supported Rehabilitation of Complex Cases: Clinical Management and Timing Strategy.

    PubMed

    Landi, Luca; Piccinelli, Stefano; Raia, Roberto; Marinotti, Fabio; Manicone, Paolo Francesco

    2016-01-01

    Treatment of complex perioprosthetic cases is one of the clinical challenges of everyday practice. Only a complete and thorough diagnostic setup may allow the clinician to formulate a realistic prognosis to select the abutments to support prosthetic rehabilitation. Clinical, radiographic, or laboratory parameters used separately are useless to correctly assign a reliable prognosis to single teeth except in the case of a clearly hopeless tooth. Therefore, it is crucial to gather the greatest quantity of data to determine the role that every single element can play in the prosthetic rehabilitation of the case. The following report deals with the management of a multidisciplinary periodontally compromised case in which a treatment strategy and chronology were designed to reach clinical predictability while reducing the duration of the therapy.

  4. Inferences and metaphoric comprehension in unilaterally implanted children with adequate formal oral language performance.

    PubMed

    Nicastri, Maria; Filipo, Roberto; Ruoppolo, Giovanni; Viccaro, Marika; Dincer, Hilal; Guerzoni, Letizia; Cuda, Domenico; Bosco, Ersilia; Prosperini, Luca; Mancini, Patrizia

    2014-05-01

    To assess skills in inferences during conversations and in metaphors comprehension of unilaterally cochlear implanted children with adequate abilities at the formal language tests, comparing them with well-matched hearing peers; to verify the influence of age of implantation on overall skills. The study was designed as a matched case-control study. 31 deaf children, unilateral cochlear implant users, with normal linguistic competence at formal language tests were compared with 31 normal hearing matched peers. Inferences and metaphor comprehension skills were assessed through the Implicit Meaning Comprehension, Situations and Metaphors subtests of the Italian Standardized Battery of "Pragmatic Language Skills MEDEA". Differences between patient and control groups were tested by the Mann-Whitney U test. Correlations between age at implantation and time of implant use with each subtest were investigated by the Spearman rank correlation coefficient. No significant differences between the two groups were found in inferencing skills (p=0.24 and p=0.011 respectively for Situations and Implicit Meaning Comprehension). Regarding figurative language, unilaterally cochlear implanted children performed significantly below their normal hearing peers in Verbal Metaphor comprehension (p=0.001). Performances were related to age at implantation, but not with time of implant use. Unilaterally cochlear implanted children with normal language level showed responses similar to NH children in discourse inferences, but not in figurative language comprehension. Metaphors still remains a challenge for unilateral implant users and above all when they have not any reference, as demonstrated by the significant difference in verbal rather than figurative metaphors comprehension. Older age at implantation was related to worse performance for all items. These aspects, until now less investigated, had to receive more attention to deeply understand specific mechanisms involved and possible effects of different levels of figurative language complexity (presence or absence of contextual input, degree of transparency and syntactic frozenness). New insight is needed to orient programs in early intervention settings in considering and adequately responding to all these complex communicative need of children with hearing loss. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. An economic evaluation of maxillary implant overdentures based on six vs. four implants.

    PubMed

    Listl, Stefan; Fischer, Leonhard; Giannakopoulos, Nikolaos Nikitas

    2014-08-18

    The purpose of the present study was to assess the value for money achieved by bar-retained implant overdentures based on six implants compared with four implants as treatment alternatives for the edentulous maxilla. A Markov decision tree model was constructed and populated with parameter estimates for implant and denture failure as well as patient-centred health outcomes as available from recent literature. The decision scenario was modelled within a ten year time horizon and relied on cost reimbursement regulations of the German health care system. The cost-effectiveness threshold was identified above which the six-implant solution is preferable over the four-implant solution. Uncertainties regarding input parameters were incorporated via one-way and probabilistic sensitivity analysis based on Monte-Carlo simulation. Within a base case scenario of average treatment complexity, the cost-effectiveness threshold was identified to be 17,564 € per year of denture satisfaction gained above of which the alternative with six implants is preferable over treatment including four implants. Sensitivity analysis yielded that, depending on the specification of model input parameters such as patients' denture satisfaction, the respective cost-effectiveness threshold varies substantially. The results of the present study suggest that bar-retained maxillary overdentures based on six implants provide better patient satisfaction than bar-retained overdentures based on four implants but are considerably more expensive. Final judgements about value for money require more comprehensive clinical evidence including patient-centred health outcomes.

  6. An economic evaluation of maxillary implant overdentures based on six vs. four implants

    PubMed Central

    2014-01-01

    Background The purpose of the present study was to assess the value for money achieved by bar-retained implant overdentures based on six implants compared with four implants as treatment alternatives for the edentulous maxilla. Methods A Markov decision tree model was constructed and populated with parameter estimates for implant and denture failure as well as patient-centred health outcomes as available from recent literature. The decision scenario was modelled within a ten year time horizon and relied on cost reimbursement regulations of the German health care system. The cost-effectiveness threshold was identified above which the six-implant solution is preferable over the four-implant solution. Uncertainties regarding input parameters were incorporated via one-way and probabilistic sensitivity analysis based on Monte-Carlo simulation. Results Within a base case scenario of average treatment complexity, the cost-effectiveness threshold was identified to be 17,564 € per year of denture satisfaction gained above of which the alternative with six implants is preferable over treatment including four implants. Sensitivity analysis yielded that, depending on the specification of model input parameters such as patients’ denture satisfaction, the respective cost-effectiveness threshold varies substantially. Conclusions The results of the present study suggest that bar-retained maxillary overdentures based on six implants provide better patient satisfaction than bar-retained overdentures based on four implants but are considerably more expensive. Final judgements about value for money require more comprehensive clinical evidence including patient-centred health outcomes. PMID:25135370

  7. An Anatomical Study of Maxillary-Zygomatic Complex Using Three-Dimensional Computerized Tomography-Based Zygomatic Implantation

    PubMed Central

    Zhao, Shijie; Liu, Hui; Sun, Zhipeng; Wang, Jianwei

    2017-01-01

    Objective To obtain anatomical data of maxillary-zygomatic complex based on simulating the zygomatic implantation using cadaver heads and three-dimensional computerized tomography (3D-CT). Methods Simulating zygomatic implantation was performed using seven cadaver heads and 3D-CT images from forty-eight adults. After measuring the maxillary-zygomatic complex, we analyzed the position between the implantation path and the maxillary sinus cavity as well as the distance between the implantation path and the zygomatic nerve. Results The distance from the starting point to the endpoint of the implant was 56.85 ± 5.35 mm in cadaver heads and 58.15 ± 7.37 mm in 3D-CT images. For the most common implantation path (80.20%), the implant went through the maxillary sinus cavity completely. The projecting points of the implant axis (IA) on the surface of zygoma were mainly located in the region of frontal process of zygomatic bone close to the lateral orbital wall. The distances between IA and zygomatic nerve in 53 sides were shorter than 2 mm. Conclusion The simulating zygomatic implantation on cadaver skulls and 3D-CT imaging provided useful anatomical data of the maxillary-zygomatic complex. It is necessary to take care to avoid the zygomatic nerve injury during implantation, because it frequently appears on the route of implantation. PMID:29376077

  8. [Clinical and ossification outcome of custom-made hydroxyapatite prothese for large skull defect].

    PubMed

    Hardy, H; Tollard, E; Derrey, S; Delcampe, P; Péron, J-M; Fréger, P; Proust, F

    2012-02-01

    Cranioplasty is an everyday concern in neurosurgery, especially in decompressive craniectomy cases. Our surgical team uses custom-made hydroxyapatite implants for large and/or complex defects. Eight patients had a custom-made prosthesis. Each of them has been reviewed by an independent observer. Each patient described his feeling of satisfaction, using a questionnaire, graduated from "A" (really satisfied) to "D" (unsatisfied). Each of them also underwent a CT-scan (helicoidal acquisition, 0.6mm thick for multiplanar reconstruction) to evaluate qualitatively the ossification graduated from "0" (no ossification) to "5" (continuous ossification). Maximal under-prosthetic bone thickness, intra-prosthetic calcic density were also reported. Supervision delay was 43.7 months [6-99 months], average defect surface was 85.5 cm(2) [27.6-137.6 cm(2)], the craniectomy etiologies were intracranial hypertension (seven patients) and calvarial invasion (one patient). Implant tolerance was reparted in "A" score (50%) and "B" score (50%). Concerning ossification, six patients (75%) had a score of "2" or less and two patients had a score of "3" or "4". Hydroxyapatite custom-made implants for cranioplasty appear to be ideal for good aesthetic and tolerance results, but their ossification is hardly analyzed due to the prosthesis density higher than the bone's density. This is why we recommend them for children and in cases of complex defects such as pterion location. Copyright © 2011. Published by Elsevier Masson SAS.

  9. Custom-made, root-analogue direct laser metal forming implant: a case report.

    PubMed

    Mangano, Francesco Guido; Cirotti, Bruno; Sammons, Rachel Lilian; Mangano, Carlo

    2012-11-01

    In the last few years, the application of digital technology in dentistry has become widespread with the introduction of cone beam computed tomography (CBCT) scan technology, and considerable progress has been made in the development of computer-aided design/ computer-aided manufacturing (CAD/CAM) techniques, including direct laser metal forming (DLMF). DLMF is a technology which allows solids with complex geometry to be produced by annealing metal powder microparticles in a focused laser beam, according to a computer-generated three-dimensional (3D) model. For dental implants, the fabrication process involves the laser-induced fusion of titanium microparticles, in order to build, layer by layer, the desired object. At present, the combined use of CBCT 3D data and CAD/CAM technology makes it possible to manufacture custom-made, root-analogue implants (RAI) with sufficient precision. This report demonstrates the successful clinical use of a custom-made, root-analogue DLMF implant. CBCT images of a non-restorable right maxillary first premolar were acquired and transformed into a 3D model. From this model, a custom-made, root-analogue DLMF implant was fabricated. Immediately after tooth extraction, the RAI with a pre-operatively designed abutment was placed in the extraction socket and restored with a single crown. At the 1-year follow-up examination, the RAI showed a good functional and aesthetic integration. The introduction of DLMF technology signals the start of a new revolutionary era for implant dentistry as its immense potential for producing highly complex macro- and microstructures is receiving vast interest in different medical fields.

  10. Resolution of Metallic Biliary Stent Allergic Reaction After Partial Stent Removal in a Patient with Nickel Sensitivity.

    PubMed

    Esparaz, Anthony M; Ahmed, Muneeb

    2017-07-01

    Local and systemic reactions to implanted metallic devices, particularly to those containing nickel, are well documented. Metal ions are released due to exposure of the metal to blood, proteins, other body fluids, and sheer mechanical stress. Metal ions then complex with native proteins and become antigens, which can elicit hypersensitivity reactions. Another case report depicts a specific allergic complication (early stent occlusion) related to metallic biliary stent implantation. We present a case of allergic symptoms, associated with eating, in a patient who developed nickel sensitivity after biliary metal stent placement confirmed by allergic skin testing to the same metallic biliary stent placed one year earlier. Symptoms resolved following partial removal of the non-epithelialized portion of the biliary stent.

  11. Orthodontic treatment of a complex open-bite malocclusion with temporary anchorage devices: a case report.

    PubMed

    Waldman, Alexander B

    2010-08-01

    Orthodontic temporary anchorage devices provide a novel alternative to orthognathic surgery for the treatment of severe anterior open-bite malocclusions. These implantable devices provide skeletal anchorage for maxillary molar intrusion, allowing for mandibular autorotation and subsequent open-bite closure. This case demonstrates step-by-step treatment of a 41-year-old woman with a severe open-bite malocclusion. Detailed orthodontic mechanics are described at every stage of treatment.

  12. Diagnosis of anaplastic large cell lymphoma on late peri-implant breast seroma: Management of cytological sample by an integrated approach.

    PubMed

    Ronchi, A; Montella, M; Argenzio, V; Lucia, A; De Renzo, A; Alfano, R; Franco, R; Cozzolino, I

    2018-04-06

    Peri-implant breast seroma is a late clinical presentation of reconstructive surgery or augmentation mammoplasty with breast implants. Pre-operative cytological evaluation of the peri-implant breast seroma is a common clinical approach, showing mainly an inflammatory reaction or more rarely a breast implant-associated anaplastic large cell lymphoma. Herein, we reported the role of cytology in the evaluation of peri-implant breast seroma and its critical pre-operative implications. Eight cases of peri-implant breast seroma from files at Luigi Vanvitelli University were identified between January and December 2017. In all cases, seroma was aspirated; cytospins were performed and stained by Papanicolaou stain; finally, in all cases, a cell block was obtained for immunocytochemical evaluation and, in one case, for FISH to detect ALK1-gene translocation. The median age of patients was 48 years and the mean time between the implant placement and the occurrence of peri-implant breast seroma was 18 months. Microscopic examination showed breast implant-associated anaplastic large cell lymphoma in one case, aspecific inflammatory reaction in six cases and silicon-associated reaction in one case. Peri-implant breast seroma may be caused by several pathological conditions with different clinical behaviour. A proper cytological approach to peri-implant breast seroma allows a correct differential diagnosis between inflammatory conditions and breast implant-associated anaplastic large cell lymphoma and an appropriate management of the patient. © 2018 John Wiley & Sons Ltd.

  13. Preload, Coefficient of Friction, and Thread Friction in an Implant-Abutment-Screw Complex.

    PubMed

    Wentaschek, Stefan; Tomalla, Sven; Schmidtmann, Irene; Lehmann, Karl Martin

    To examine the screw preload, coefficient of friction (COF), and tightening torque needed to overcome the thread friction of an implant-abutment-screw complex. In a customized load frame, 25 new implant-abutment-screw complexes including uncoated titanium alloy screws were torqued and untorqued 10 times each, applying 25 Ncm. Mean preload values decreased significantly from 209.8 N to 129.5 N according to the number of repetitions. The overall COF increased correspondingly. There was no comparable trend for the thread friction component. These results suggest that the application of a used implant-abutment-screw complex may be unfavorable for obtaining optimal screw preload.

  14. Implantation, removal and replacement of subretinal electronic implants for restoration of vision in patients with retinitis pigmentosa.

    PubMed

    Gekeler, Katrin; Bartz-Schmidt, Karl Ulrich; Sachs, Helmut; MacLaren, Robert E; Stingl, Katarina; Zrenner, Eberhart; Gekeler, Florian

    2018-05-01

    The purpose of this review is to provide an update on the efforts to restore vision through subretinal implants in patients with degenerative retinal diseases. In addition to the current technique and its latest improvements, it will focus on the surgical technique of implantation as well as explantation and reimplantation. The durability of the current subretinal implant RETINA IMPLANT Alpha AMS has increased substantially compared with the predecessor model RETINA IMPLANT Alpha IMS. According to validated examinations in the laboratory, a median lifetime of 4.7 years will be reached in clinical use; in similar examinations, the previous model has reached only 8 months. Visual function has slightly increased. The surgical technique for subretinal implants is complex and demanding for ophthalmic surgeons, as it is multifaceted and combines novel surgical steps in areas, which are not commonly entered such as the suprachoroidal and the subretinal space. The surgical approach for implantation has matured considerably and has led to successful implantation in 64 patient cases. Surgical challenges are now mainly encountered with the exact subfoveal positioning of the device. The explantation procedure is relatively straight-forward because the implant can be withdrawn in a reverse direction along the already existent subretinal path. Reimplantations, however, are more challenging because some degree of scar tissue may exist along the path of the chip and around the scleral trapdoor. Nevertheless, reimplantations have now been carried out successfully in four patients. The new RETINA IMPLANT Alpha AMS shows significantly improved durability compared with the predecessor model RETINA IMPLANT Alpha IMS. The subretinal implant offers excellent visual results but requires experienced surgeons. Explantation of devices is straight-forward, and reimplantations are challenging but have been successful in four patients.

  15. Kinematic and fatigue biomechanics of an interpositional facet arthroplasty device.

    PubMed

    Dahl, Michael C; Freeman, Andrew L

    2016-04-01

    Although approximately 30% of chronic lumbar pain can be attributed to the facets, limited surgical options exist for patients. Interpositional facet arthroplasty (IFA) is a novel treatment for lumbar facetogenic pain designed to provide patients who gain insufficient relief from medical interventional treatment options with long-term relief, filling a void in the facet pain treatment continuum. This study aimed to quantify the effect of IFA on segmental range of motion (ROM) compared with the intact state, and to observe device position and condition after 10,000 cycles of worst-case loading. In situ biomechanical analysis of the lumbar spine following implantation of a novel IFA device was carried out. Twelve cadaveric functional spinal units (L2-L3 and L5-S1) were tested in 7.5 Nm flexion-extension, lateral bending, and torsion while intact and following device implantation. Additionally, specimens underwent 10,000 cycles of worst-case complex loading and were testing in ROM again. Load-displacement and fluoroscopic data were analyzed to determine ROM and to evaluate device position during cyclic testing. Devices and facets were evaluated post testing. Institutional support for implant evaluation was received by Zyga Technology. Range of motion post implantation decreased versus intact, and then was restored post cyclic-testing. Of the tested devices, 6.5% displayed slight movement (0.5-2 mm), all from tight L2-L3 facet joints with misplaced devices or insufficient cartilage. No damage was observed on the devices, and wear patterns were primarily linear. The results from this in situ cadaveric biomechanics and cyclic fatigue study demonstrate that a low-profile, conformable IFA device can maintain position and facet functionality post implantation and through 10,000 complex loading cycles. In vivo conditions were not accounted for in this model, which may affect implant behavior not predictable via a biomechanical study. However, these data along with published 1-year clinical results suggest that IFA may be a valid treatment option in patients with chronic lumbar zygapophysial pain who have exhausted medical interventional options. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  16. The effects of familiarity and complexity on appraisal of complex songs by cochlear implant recipients and normal hearing adults.

    PubMed

    Gfeller, Kate; Christ, Aaron; Knutson, John; Witt, Shelley; Mehr, Maureen

    2003-01-01

    The purposes of this study were (a) to develop a test of complex song appraisal that would be suitable for use with adults who use a cochlear implant (assistive hearing device) and (b) to compare the appraisal ratings (liking) of complex songs by adults who use cochlear implants (n = 66) with a comparison group of adults with normal hearing (n = 36). The article describes the development of a computerized test for appraisal, with emphasis on its theoretical basis and the process for item selection of naturalistic stimuli. The appraisal test was administered to the 2 groups to determine the effects of prior song familiarity and subjective complexity on complex song appraisal. Comparison of the 2 groups indicates that the implant users rate 2 of 3 musical genres (country western, pop) as significantly more complex than do normal hearing adults, and give significantly less positive ratings to classical music than do normal hearing adults. Appraisal responses of implant recipients were examined in relation to hearing history, age, performance on speech perception and cognitive tests, and musical background.

  17. Effect of the order of He{sup +} and H{sup +} ion co-implantation on damage generation and thermal evolution of complexes, platelets, and blisters in silicon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daghbouj, N.; Faculté des Sciences de Monastir, Université de Monastir, Monastir; Cherkashin, N., E-mail: nikolay.cherkashin@cemes.fr

    2016-04-07

    Hydrogen and helium co-implantation is nowadays used to efficiently transfer thin Si layers and fabricate silicon on insulator wafers for the microelectronic industry. The synergy between the two implants which is reflected through the dramatic reduction of the total fluence needed to fracture silicon has been reported to be strongly influenced by the implantation order. Contradictory conclusions on the mechanisms involved in the formation and thermal evolution of defects and complexes have been drawn. In this work, we have experimentally studied in detail the characteristics of Si samples co-implanted with He and H, comparing the defects which are formed followingmore » each implantation and after annealing. We show that the second implant always ballistically destroys the stable defects and complexes formed after the first implant and that the redistribution of these point defects among new complexes drives the final difference observed in the samples after annealing. When H is implanted first, He precipitates in the form of nano-bubbles and agglomerates within H-related platelets and nano-cracks. When He is implanted first, the whole He fluence is ultimately used to pressurize H-related platelets which quickly evolve into micro-cracks and surface blisters. We provide detailed scenarios describing the atomic mechanisms involved during and after co-implantation and annealing which well-explain our results and the reasons for the apparent contradictions reported at the state of the art.« less

  18. A Retrospective Analysis of Ruptured Breast Implants

    PubMed Central

    Baek, Woo Yeol; Lew, Dae Hyun

    2014-01-01

    Background Rupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants. Methods We performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone), duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management. Results Forty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case), microfat graft (2 case), removal only (14 case), and follow-up loss (17 case). Conclusions Saline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs. PMID:25396188

  19. Integration of an Axcelis Optima HD Single Wafer High Current Implanter for p- and n-S/D Implants in an Existing Batch Implanter Production Line

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmeide, Matthias; Kontratenko, Serguei; Krimbacher, Bernhard

    2008-11-03

    This paper is focused on the integration and qualification of an Axcelis Optima HD single wafer high current spot beam implanter in an existing 200 mm production line with different types of Axcelis batch implanters for high current applications. Both the design of the beamline and the beam shape are comparable between single wafer and batch high current spot beam implanters. In contrast to the single wafer high current ribbon beam implanter, energy contamination is not a concern for the considered spot beam tool because the drift mode can be used down to energies in the 2 keV region. Themore » most important difference between single wafer and batch high current implanters is the significantly higher dose rate and, therefore, the higher damage rate for the single wafer tool due to the different scanning architecture. The results of the integration of high dose implantations, mainly for p- and n-S/D formation, for DRAM 110 nm without pre-amorphization implantation (PAI), CMOS Logic from around 250 nm down to 90 nm without and with PAI, are presented and discussed. Dopant concentration profile analysis using SIMS was performed for different technologies and implantation conditions. The impurity activation was measured using sheet resistance and in some cases spreading resistance technique was applied. The amorphous layer thickness was measured using TEM. Finally, device data are presented in combination with dose, energy and beam current variations. The results have shown that the integration of implantation processes into crystalline structure without PAI is more complex and time consuming than implantations into amorphous layer where the damage difference due to the different dose rates is negligible.« less

  20. Management of dental implant fractures. A case history.

    PubMed

    Al Quran, Firas A M; Rashan, Bashar A; Al-Dwairi, Ziad N

    2009-01-01

    The widespread use of endosseous osseointegrated implants to replace missing natural teeth increases the chances of implant complications and failures, despite the high initial success rate reported in the literature. Implant fracture is one possible complication that results in ultimate failure of the dental implant. Such a complication poses a management crisis even for the most experienced clinician. This article reports on a case of implant fracture, its possible causes, and how the case was managed.

  1. Inadvertent defibrillator lead placement into the left ventricle after MitraClip implantation: A case report.

    PubMed

    Santarpia, Giuseppe; Passafaro, Francesco; Pasceri, Eugenia; Mongiardo, Annalisa; Curcio, Antonio; Indolfi, Ciro

    2018-05-01

    Inadvertent pacemaker/defibrillator lead placement into the left ventricle is an unusual cardiac device-related complication and its diagnosis is not always easy and often misunderstood. Thromboembolic events are frequently associated with this procedural complication. Percutaneous lead extraction should be performed when diagnosis is made early after device implantation while long-life oral anticoagulation is a wise option when the diagnosis is delayed and the lead is not removed. A 65-year-old man affected by dilated cardiomyopathy, previously treated with a percutaneous mitral valve repair, with 2 MitraClip devices, and later with dual chamber cardioverter/defibrillator implantation, returned in outpatient clinics 2 months after discharge for deterioration of dyspnea; transthoracic echocardiography revealed that the shock lead had been accidentally placed in the apex of the left ventricle. The unintentional lead malposition through the iatrogenic atrial septal defect and its presence into the mitral valve orifice, together with the 2 clip devices implanted, generated an acceleration of transvalvular diastolic flow, determining a moderate stenosis of the mitral valve, as well as promoting a worsening of the degree of valvular regurgitation. Oral anticoagulation therapy was started and a mechanical lead extraction was percutaneously performed. A new defibrillator lead was later appropriately positioned in the apex of the right ventricle. The patient was discharged 3 days after intervention and the follow-up, performed 1 month after discharge, was uneventful. Complex interventional procedures and implantation of multiple devices can increase procedural troubles and the risk of mechanical complications related to pacemaker/defibrillator implantation. Careful observation of the QRS complex morphology on the electrocardiogram (ECG), during paced rhythm, and the achievement of the echocardiographic examination, in the postprocedural phase, allow an early diagnosis of lead malposition.

  2. [3D bioprinting of cartilage: challenges concerning the reconstruction of a burned ear].

    PubMed

    Visscher, Dafydd O; Bos, Ernst J; van Zuijlen, Paul P M

    2015-01-01

    Reconstruction of a severely maimed ear is a major challenge. The ear is highly flexible yet tough, and has a very complex three-dimensional shape. Reconstruction of a patient's burned ear is even more complex due to surrounding tissue damage. Not only does this hamper reconstruction options, it also increases the likelihood of issues when using synthetic implant materials. In such cases, rib cartilage is the preferred option, but this tissue has practical limitations too. For these reasons, tissue engineering and 3D bioprinting may have the potential to create personalized cartilage implants for burns patients. However, 3D bioprinting is a tool to facilitate the reconstruction, and not by itself the Holy Grail. The clinical application of this technique is still at a very early stage. Nevertheless, we expect that 3D bioprinting can be utilised for facial reconstruction following burns come 2020.

  3. Displacement of a dental implant into the maxillary sinus after internal sinus floor elevation: report of a case and review of literature.

    PubMed

    Ding, Xiaojun; Wang, Qing; Guo, Xuehua; Yu, Youcheng

    2015-01-01

    Dental implant placement in the posterior maxilla may be complicated by implant migration into the maxillary sinus. To report the clinical and radiological characteristics of a patient who experienced dental implant displacement into the maxillary sinus following sinus floor elevation, and to compare our findings with those of other published reports of the displacement of dental implants. Implant placement and maxillary sinus elevation were performed simultaneously. The location of the displaced implant was monitored for 8 years, until the ectopic implant was surgically removed using the lateral window approach. The contributing factors, treatment modality, and clinical outcome for our patient were compared with those of patients reported in the literature. The clinical characteristics of our case were similar to those of patients with displaced implants who were also asymptomatic for long periods. The clinical outcome of our case was consistent with that of patients who underwent similar surgeries. Transnasal endoscopic removal of an ectopic implant may be suitable in cases in which the ectopic implant is accessible. Transoral direct approaches are adequate in most cases in which endoscopic approaches may be confounded. The bony-window transoral technique may allow the removal of large implants.

  4. Floor-of-Mouth Hematoma Following Dental Implant Placement: Literature Review and Case Presentation.

    PubMed

    Law, Catherine; Alam, Peyman; Borumandi, Farzad

    2017-11-01

    The authors provide a structured review of reported cases of floor-of-mouth hematoma during or after dental implantation and frequent causes and management and present a related case. An online search of the medical literature was conducted from 1990 through 2016. The following search terms were used: floor of mouth hematoma, sublingual hematoma, dental implant hematoma, implant in mandible, and complication of dental implant. Abstracts were screened for relevance to the aims of the review. Relevant reports in the English language were included and referenced. The articles were reviewed for patient demographics, implant location, coagulopathy, pre- or postoperative imaging, airway management, treatment of the hematoma, and management of the offending implant. The literature search identified 25 reported cases. Hemorrhage was caused by perforation of the lingual cortex in 84% of cases (n = 21). Airway obstruction resulted in emergency intubation or tracheostomy in 68% of patients (n = 17). Most cases (n = 18; 72%) required surgical management in the hospital setting. Management of the offending implant was reported inconsistently. Of 17 reported cases, 5 implants had to be removed, 9 remained in situ, and in 3 cases implant placement was abandoned. Only 1 case involved preoperative 3-dimensional (3D) imaging before implant insertion. The authors report on an additional case with a serious floor-of-mouth hematoma that required immediate surgical evacuation and hemostasis. Serious complications, such as floor-of-mouth hematoma after dental implant insertion, can occur, which could be life-threatening. Preoperative 3D imaging helps to visualize the individual mandibular shape, which could decrease the incidence of serious complications. If injury to vessels of the floor of the mouth cannot be confidently excluded, then further assessment and treatment are recommended before the patient is discharged. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Hydroxyapatite ocular implant and non-integrated implants in eviscerated patients

    PubMed Central

    Gradinaru, S; Popescu, V; Leasu, C; Pricopie, S; Yasin, S; Ciuluvica, R; Ungureanu, E

    2015-01-01

    Introduction: This study compares the outcomes and complications of hydroxyapatite ocular implant and non-integrated ocular implants following evisceration. Materials and Methods: This is a retrospective study of 90 patients who underwent evisceration for different ocular affections, in the Ophthalmology Department of the University Emergency Hospital Bucharest, between January 2009 and December 2013. The outcomes measured were conjunctival dehiscence, socket infection, implant exposure and extrusion rate. Results: Forty-three patients had the hydroxyapatite implant (coralline–Integrated Ocular Implants, USA or synthetic–FCI, France) and forty-seven received non-integrated ocular implants (24 acrylic and 23 silicone). Five cases of socket infection, thirteen cases of extrusion and two cases of conjunctival dehiscence were encountered. Conclusions: There was a higher rate of conjunctival dehiscence with hydroxyapatite ocular implant, but implant extrusion and socket infection were found in non-integrated ocular implants. PMID:25914747

  6. Complex radial folds versus subtle signs of intracapsular rupture of breast implants: MR findings with surgical correlation.

    PubMed

    Soo, M S; Kornguth, P J; Walsh, R; Elenberger, C D; Georgiade, G S

    1996-06-01

    Detection of intracapsular rupture of silicone breast prostheses using MR imaging is often performed by identifying the "linguine sign" [1]. The linguine sign is easily differentiated from simple radial folds that are seen in intact implants. However, more subtle signs of intracapsular rupture, including undulating subcapsular lines and the "teardrop sign," are less often recognized [2-5] and may prove difficult for the less experienced radiologist to differentiate from complex radial folds of intact implants. In this essay, we illustrate the MR imaging findings of complex radial folds in intact implants and compare them with findings of incomplete shell collapse in ruptured implants in a surgically confirmed series of explanted silicone breast prostheses.

  7. Nummular Eczema of Breast: A Potential Dermatologic Complication after Mastectomy and Subsequent Breast Reconstruction

    PubMed Central

    Iwahira, Yoshiko; Nagasao, Tomohisa; Shimizu, Yusuke; Kuwata, Kumiko; Tanaka, Yoshio

    2015-01-01

    Purposes. The present paper reports clinical cases where nummular eczema developed during the course of breast reconstruction by means of implantation and evaluates the occurrence patterns and ratios of this complication. Methods. 1662 patients undergoing breast reconstruction were reviewed. Patients who developed nummular eczema during the treatment were selected, and a survey was conducted on these patients regarding three items: (1) the stage of the treatment at which nummular eczema developed; (2) time required for the lesion to heal; (3) location of the lesion on the reconstructed breast(s). Furthermore, histopathological examination was conducted to elucidate the etiology of the lesion. Results. 48 patients (2.89%) developed nummular eczema. The timing of onset varied among these patients, with lesions developing after the placement of tissue expanders for 22 patients (45.8%); after the tissue expanders were replaced with silicone implants for 12 patients (25%); and after nipple-areola complex reconstruction for 14 patients (29.2%). Nummular eczema developed both in periwound regions (20 cases: 41.7%) and in nonperiwound regions (32 cases: 66.7%). Histopathological examination showed epidermal acanthosis, psoriasiform patterns, and reduction of sebaceous glands. Conclusions. Surgeons should recognize that nummular eczema is a potential complication of breast reconstruction with tissue expanders and silicone implants. PMID:26380109

  8. Novel Solution for Massive Glenoid Defects in Shoulder Arthroplasty: A Patient-Specific Glenoid Vault Reconstruction System.

    PubMed

    Dines, David M; Gulotta, Lawrence; Craig, Edward V; Dines, Joshua S

    Complex glenoid deformities present the most difficult challenges in shoulder arthroplasty. These deformities may be caused by severe degenerative or congenital deformity, posttraumatic anatomy, tumor, or, in most cases, bone loss after glenoid failure in anatomical total shoulder arthroplasty. Methods of treating severe bone loss have included inlay and onlay bone-graft options with augmented fixation and, in severe cases, salvage hemiarthroplasty with limited goal expectations. Unfortunately, none of these methods has provided consistently satisfactory reproducible results. In fact, each has had high rates of failure and complications. Borrowing from hip and knee arthroplasty surgeons' experience in using CAD/CAM (computer-aided design/computer-aided manufacturing) patient-specific implants to fill significant bony defects, Dr. D. M. Dines developed a glenoid vault reconstruction system (VRS) in conjunction with the Comprehensive Shoulder Arthroplasty System (Zimmer Biomet) to treat severe glenoid bone deficiency. The VRS is patient-specific; each case involves making a preoperative plan based on 3-dimensional reconstruction of a 2-dimensional computed tomography scan. The patient-specific implant and instrumentation that are created are used to reconstruct the deformed glenoid in an anatomical position without the need for additional bone graft. In this article, we describe the implant and its indications, technical aspects of production, and surgical technique.

  9. Relationship between oral cancer and implants: clinical cases and systematic literature review

    PubMed Central

    López-López, José; Roselló-Llabrés, Xavier; Rodríguez-Argueta, Oscar-Francisco; Chimenos-Küstner, Eduardo

    2012-01-01

    The use of implants for oral rehabilitation of edentulous spaces has recently been on the increase, which has also led to an increase in complications such as peri-implant inflammation or periimplantitis. Chronic inflammation is a risk factor for developing oral squamous cell carcinoma (OSCC). Objectives: To review the literature of cases that associate implant placement with the development of oral cancer. Study design: We present two clinical cases and a systematic review of literature published on the relationship between oral cancer and implants. Results: We found 13 articles published between the years 1996 and 2009, referencing 18 cases in which the osseointegrated implants are associated with oral squamous cell carcinoma. Of those, 6 articles were excluded because they did not meet the inclusion criteria. Of the 18 cases reported, only 7 cases did not present a previous history of oral cancer or cancer in other parts of the body. Conclusions: Based on the review of these cases, a clear cause-effect relationship cannot be established, although it can be deduced that there is a possibility that implant treatment may constitute an irritant and/or inflammatory cofactor which contributes to the formation and/or development of OSCC. Key words: Cancer, oral cancer, dental implants, oral squamous cell carcinoma, dental implants complications. PMID:21743414

  10. [Custom-made implant for complex facial reconstruction: A case of total replacement of temporo-mandibular joint, zygomatic arch and malar bone].

    PubMed

    Guillier, D; Moris, V; See, L-A; Girodon, M; Wajszczak, B-L; Zwetyenga, N

    2017-02-01

    Total prosthetic replacement of the temporo-mandibular joint (TMJ) has become a common procedure, but it is usually limited to the TMJ itself. We report about one case of complex prosthetic joint reconstruction extending to the neighbouring bony structures. A 57-year-old patient, operated several times for a cranio-facial fibrous dysplasia, presented with a recurring TMJ ankylosis and a complexe latero-facial bone loss on the right side. We performed a reconstruction procedure including the TMJ, the zygomatic arch and the malar bone by mean of custom made composite prosthesis (chrome-cobalt-molybdenum-titanium and polyethylene). Five years postoperatively, mouth opening, nutrition, pain and oral hygiene were significantly improved. Nowadays technical possibilities allow for complex facial alloplastic reconstructions with good medium term results. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. Realization of Complex Onsets by Pediatric Users of Cochlear Implants

    ERIC Educational Resources Information Center

    Chin, Steven B.

    2006-01-01

    This study examined variations in English complex onset realizations by children who use cochlear implants. Data consisted of 227 productions of two-segment onset clusters from 12 children. In general, onset cluster realizations of children with cochlear implants did not differ markedly from those reported for children with normal hearing: null…

  12. Children with Cochlear Implants and Complex Needs: A Review of Outcome Research and Psychological Practice

    ERIC Educational Resources Information Center

    Edwards, Lindsay C.

    2007-01-01

    In recent years, the number of children receiving cochlear implants who have significant disabilities in addition to their deafness has increased substantially. However, in comparison with the extensive literature on speech, language, and communication outcomes following pediatric implantation in children without complex needs, the available…

  13. Human implantation: the last barrier in assisted reproduction technologies?

    PubMed

    Edwards, Robert G

    2006-12-01

    Implantation processes are highly complex involving the actions of numerous hormones, immunoglobulins, cytokines and other factors in the endometrium. They are also essential matters for the success of assisted reproduction. The nature of early embryonic development is of equal significance. It involves ovarian follicle growth, ovulation, fertilization and preimplantation growth. These processes are affected by imbalanced chromosomal constitutions or slow developmental periods. Post-implantation death is also a significant factor in cases of placental insufficiency or recurrent abortion. Clearly, many of these matters can significantly affect birth rates. This review is concerned primarily with the oocyte, the early embryo and its chromosomal anomalies, and the nature of factors involved in implantation. These are clearly among the most important features in determining successful embryonic and fetal growth. Successive sections cover the endocrine stimulation of follicle growth in mice and humans, growth of human embryos in vitro, their apposition and attachment to the uterus, factors involved in embryo attachment to uterine epithelium and later stages of implantation, and understanding the gene control of polarities and other aspects of preimplantation embryo differentiation. New aspects of knowledge include the use of human oocyte maturation in vitro as an approach to simpler forms of IVF, and new concepts in developmental genetics.

  14. Cutaneous and systemic hypersensitivity reactions to metallic implants.

    PubMed

    Basko-Plluska, Juliana L; Thyssen, Jacob P; Schalock, Peter C

    2011-01-01

    Cutaneous reactions to metal implants, orthopedic or otherwise, are well documented in the literature. The first case of a dermatitis reaction over a stainless steel fracture plate was described in 1966. Most skin reactions are eczematous and allergic in nature, although urticarial, bullous, and vasculitic eruptions may occur. Also, more complex immune reactions may develop around the implants, resulting in pain, inflammation, and loosening. Nickel, cobalt, and chromium are the three most common metals that elicit both cutaneous and extracutaneous allergic reactions from chronic internal exposure. However, other metal ions as well as bone cement components can cause such hypersensitivity reactions. To complicate things, patients may also develop delayed-type hypersensitivity reactions to metals (ie, in-stent restenosis, prosthesis loosening, inflammation, pain, or allergic contact dermatitis) following the insertion of intravascular stents, dental implants, cardiac pacemakers, or implanted gynecologic devices. Despite repeated attempts by researchers and clinicians to further understand this difficult area of medicine, the association between metal sensitivity and cutaneous allergic reactions remains to be fully understood. This review provides an update of the current knowledge in this field and should be valuable to health care providers who manage patients with conditions related to this field.

  15. Implementing Capsule Representation in a Total Hip Dislocation Finite Element Model

    PubMed Central

    Stewart, Kristofer J; Pedersen, Douglas R; Callaghan, John J; Brown, Thomas D

    2004-01-01

    Previously validated hardware-only finite element models of THA dislocation have clarified how various component design and surgical placement variables contribute to resisting the propensity for implant dislocation. This body of work has now been enhanced with the incorporation of experimentally based capsule representation, and with anatomic bone structures. The current form of this finite element model provides for large deformation multi-body contact (including capsule wrap-around on bone and/or implant), large displacement interfacial sliding, and large deformation (hyperelastic) capsule representation. In addition, the modular nature of this model now allows for rapid incorporation of current or future total hip implant designs, accepts complex multi-axial physiologic motion inputs, and outputs case-specific component/bone/soft-tissue impingement events. This soft-tissue-augmented finite element model is being used to investigate the performance of various implant designs for a range of clinically-representative soft tissue integrities and surgical techniques. Preliminary results show that capsule enhancement makes a substantial difference in stability, compared to an otherwise identical hardware-only model. This model is intended to help put implant design and surgical technique decisions on a firmer scientific basis, in terms of reducing the likelihood of dislocation. PMID:15296198

  16. Observation of enhanced infrared absorption in silicon supersaturated with gold by pulsed laser melting of nanometer-thick gold films

    NASA Astrophysics Data System (ADS)

    Chow, Philippe K.; Yang, Wenjie; Hudspeth, Quentin; Lim, Shao Qi; Williams, Jim S.; Warrender, Jeffrey M.

    2018-04-01

    We demonstrate that pulsed laser melting (PLM) of thin 1, 5, and 10 nm-thick vapor-deposited gold layers on silicon enhances its room-temperature sub-band gap infrared absorption, as in the case of ion-implanted and PLM-treated silicon. The former approach offers reduced fabrication complexity and avoids implantation-induced lattice damage compared to ion implantation and pulsed laser melting, while exhibiting comparable optical absorptance. We additionally observed strong broadband absorptance enhancement in PLM samples made using 5- and 10-nm-thick gold layers. Raman spectroscopy and Rutherford backscattering analysis indicate that such an enhancement could be explained by absorption by a metastable, disordered and gold-rich surface layer. The sheet resistance and the diode electrical characteristics further elucidate the role of gold-supersaturation in silicon, revealing the promise for future silicon-based infrared device applications.

  17. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates.

    PubMed

    Nickenig, Hans-Joachim; Eitner, Stephan

    2007-01-01

    We assessed the reliability of implant placement after virtual planning of implant positions using cone-beam CT data and surgical guide templates. A total of 102 patients (250 implants, 55.4% mandibular; mean patient age, 40.4 years) who had undergone implant treatment therapy in an armed forces dental clinic (Cologne, Germany) between July 1, 2005 and December 1, 2005. They were treated with a system that allows transfer of virtual planning to surgical guide templates. Only in eight cases the surgical guides were not used because a delayed implant placement was necessary. In four posterior mandibular cases, handling was limited because of reduced interocclusal distance, requiring 50% shortening of the drill guides. The predictability of implant size was high: only one implant was changed to a smaller diameter (because of insufficient bone). In all cases, critical anatomical structures were protected and no complications were detected in postoperative panoramic radiographs. In 58.1% (147) of the 250 implants, a flapless surgery plan was realized. Implant placement after virtual planning of implant positions using cone beam CT data and surgical templates can be reliable for preoperative assessment of implant size, position, and anatomical complications. It is also indicative of cases amenable to flapless surgery.

  18. Combined Soft and Hard Tissue Peri-Implant Plastic Surgery Techniques to Enhance Implant Rehabilitation: A Case Report

    PubMed Central

    Baltacıoğlu, Esra; Korkmaz, Fatih Mehmet; Bağış, Nilsun; Aydın, Güven; Yuva, Pınar; Korkmaz, Yavuz Tolga; Bağış, Bora

    2014-01-01

    This case report presents an implant-aided prosthetic treatment in which peri-implant plastic surgery techniques were applied in combination to satisfactorily attain functional aesthetic expectations. Peri-implant plastic surgery enables the successful reconstruction and restoration of the balance between soft and hard tissues and allows the option of implant-aided fixed prosthetic rehabilitation. PMID:25489351

  19. Surface modification of biomedical and dental implants and the processes of inflammation, wound healing and bone formation.

    PubMed

    Stanford, Clark M

    2010-01-25

    Bone adaptation or integration of an implant is characterized by a series of biological reactions that start with bone turnover at the interface (a process of localized necrosis), followed by rapid repair. The wound healing response is guided by a complex activation of macrophages leading to tissue turnover and new osteoblast differentiation on the implant surface. The complex role of implant surface topography and impact on healing response plays a role in biological criteria that can guide the design and development of future tissue-implant surface interfaces.

  20. Lumbar lateral shift in a patient with interspinous device implantation: a case report.

    PubMed

    Peterson, Seth; Hodges, Cheri

    2016-09-01

    Lumbar lateral shift (LLS) is a common clinical observation but has rarely been described in a patient with a history of lumbar surgery. The purpose of the current case report was to describe the use of the McKenzie Method of Mechanical Diagnosis and Therapy (MDT) in the multi-modal treatment of a patient with an LLS and a history of multiple surgical procedures in the lumbar spine, including interspinous process device (IPD) implantation. A 72-year-old female with chronic low back pain (LBP) and a surgical history in the lumbar spine was referred to physical therapy for radiating leg pain and presented with a right LLS. Her chief complaints included sitting for long periods, vacuuming and ascending stairs into her home. The patient was treated during eight visits over 30 days. Treatment interventions included manual shift correction, self-correction and management, joint mobilisation below the level of IPD implantation ,neurophysiology education, and development of a home exercise programme. At discharge, her leg pain was resolved and all goals had been met. The patient reported maintenance of gains at 6-month follow-up. Utilisation of the MDT approach, including LLS correction, produced positive outcomes in a complex patient with previous IPD implantation. Future research should investigate treatment and outcomes after invasive spinal procedures in similar patient populations to better inform clinical management. 4.

  1. Clavicle anatomical osteosynthesis plate breakage - failure analysis report based on patient morphological parameters.

    PubMed

    Marinescu, Rodica; Antoniac, Vasile Iulian; Stoia, Dan Ioan; Lăptoiu, Dan Constantin

    2017-01-01

    Clavicle fracture reported incidence is about 5% of fractures in adult; among them, those located in the middle third of the shaft represent more than 80% from the total of cases. Due to the special morphological and biomechanical constraints of the clavicle, several methods for restoring morphological integrity in these fractures are described, including conservative, non-surgical treatment. The last 10 years of clinical studies in the field have favored the surgical treatment for selected cases; several osteosynthesis implants are in use - mostly anatomical plates with specific advantages and documented complications. A failed anatomical clavicle plate was explanted and analyzed after a protocol using stereomicroscopy, scanning electron microscopy and energy dispersive spectrometry. Based on the computed tomography (CT) scan determination of patient morphological parameters, a finite elements analysis of the failure scenario was completed. The failure analysis has proved that the plate breakage had occurred in the point of maximal elastic stress and minor deformation. The clinical implication is that no hole should remain free of screw during clavicle plate fixation and the implant should be chosen based on patient morphological parameters. In comminuted clavicle fracture, anatomic bridging with locked plate technique may lead to implant failure due to increase of the stress in the midshaft area. Thorough knowledge of anatomy and morphology of complex bones like the clavicle is necessary. Modern osteosynthesis anatomical implants are still to be improved.

  2. Anaplastic large cell lymphoma and breast implants: five Australian cases.

    PubMed

    Taylor, Kim O; Webster, Howard R; Prince, H Miles

    2012-04-01

    There has never been a convincing association between breast implants and breast malignancy. A total of 42 cases of non-Hodgkin's lymphoma of the breast associated with implant capsules have been reported. The majority of the patients have anaplastic large cell lymphoma of T-cell origin. These lymphoma types have less frequently been observed in women without implants. The senior author (H.R.W.) diagnosed and treated two women with anaplastic large cell lymphoma in a short period of time. After this, the authors were contacted by other surgeons in Australia who had treated similar cases. The authors report five new cases of anaplastic large cell lymphoma associated with breast implants. There is an apparent spectrum of disease, with some cases pursuing an aggressive clinical course, although most have experienced a good prognosis. Both saline and silicone implants are implicated. All implant shells were textured. Textured surface implants only became widely used in the 1990s and therefore were not significantly represented in the large cohort studies of breast implant safety undertaken in the early 1990s. The diagnosis of anaplastic large cell lymphoma in the breast needs to be considered in patients, particularly those presenting with a periprosthetic seroma 6 months or more after breast implant insertion. Risk, V.

  3. Cadaveric feasibility study of da Vinci Si-assisted cochlear implant with augmented visual navigation for otologic surgery.

    PubMed

    Liu, Wen P; Azizian, Mahdi; Sorger, Jonathan; Taylor, Russell H; Reilly, Brian K; Cleary, Kevin; Preciado, Diego

    2014-03-01

    To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the surgeon's confidence, as well as surgical safety, efficiency, and precision by filtering tremor. The integration of augmented reality may be valuable for surgeons dealing with complex cases of congenital anatomic abnormality, for revision cochlear implant with distorted anatomy and poorly pneumatized mastoids, and as a method of interactive teaching. Further research into the cost-benefit ratio of da Vinci Si-assisted otologic surgery, as well as refinements of the proposed workflow, are required before considering clinical studies.

  4. Orbital implant exposure treatment with porcine dermal collagen patching.

    PubMed

    Alwitry, A; Burns, S J; Abercrombie, L C

    2006-09-01

    To present a small case series of orbital implant exposures treated with porcine dermal collagen (Permacol, Tissue Science Laboratories PLC, Aldershot, Hants, UK) patching. A retrospective chart review of three cases of orbital implant exposure treated with Permacol patching. Three cases were identified. There were 4 operative episodes of Permacol patching (one socket had two attempts at permacol patching). In all 4 cases the patch rapidly failed and melted away leaving behind the orbital implant exposure. All 3 patients required implant removal. Orbital implant exposure remains a major long-term complication of evisceration and enucleation procedures. On the basis of our experience, we would not recommend using Permacol as a non-autologous material for covering exposed Medpor (Medpor, Porex Surgical, Atlanta, Georgia, USA) orbital implants. Further study is required to fully assess the safety and efficacy profile of Permacol in socket surgery.

  5. Prosthetic management of malpositioned implant using custom cast abutment

    PubMed Central

    Chatterjee, Aishwarya; Ragher, Mallikarjuna; Patil, Sanket; Chatterjee, Debopriya; Dandekeri, Savita; Prabhu, Vishnu

    2015-01-01

    Two cases are reported with malpositioned implants. Both the implants were placed 6–7 months back. They had osseointegrated well with the surrounding bone. However, they presented severe facial inclination. Case I was restored with custom cast abutment with an auto polymerizing acrylic gingival veneer. Case II was restored with custom cast UCLA type plastic implant abutment. Ceramic was directly fired on the custom cast abutments. The dual treatment strategy resulted in functional and esthetic restorations despite facial malposition of the implants. PMID:26538957

  6. Prophylactic Antibiotics for Enucleation and Evisceration: A Retrospective Study and Systematic Literature Review.

    PubMed

    Pariseau, Brett; Fox, Barry; Dutton, Jonathan J

    To report surgical site infection (SSI) rates of eviscerations and enucleations with implants performed without perioperative intravenous (IV) antibiotics or postoperative oral antibiotics, and to give SSI prevention recommendations. A single-center retrospective chart review was performed after obtaining institutional review board approval. Charts were found by Current Procedural Terminology codes. Demographics, surgical indication, procedure, implant, antibiotic use, and postoperative course were recorded. SSIs occurring within 30 days after surgery were reviewed and postoperative infection rates were determined. Four hundred eighty-one cases from January 1999 to December 2015 were analyzed. There were 102 eviscerations with implants, 314 enucleations with implants, 23 enucleations without implants, 23 implant exchanges, 15 implants placed secondarily after enucleation, and 4 implant removals. Seventy cases (14.6%) were given perioperative IV antibiotics, and in this group one periorbital infection occurred unrelated to orbital surgery (1.4%). Of the 411 cases (85.4%) not given perioperative IV antibiotics, 1 of 87 eviscerations with implants developed an SSI (1.1%), 2 of 273 enucleations with implants developed SSIs (0.7%), and none of the 13 enucleations without implants developed SSIs. To our knowledge, this is the first published case series reporting SSI rates of enucleations and eviscerations with implants performed without perioperative IV antibiotics or postoperative oral antibiotics. With infection rates comparing favorably to other case series where antibiotics were given, the routine use of perioperative IV antibiotics and postoperative oral antibiotics for enucleations and eviscerations may not be indicated.

  7. Correction of a malpositioned endosseous implant by a segmental osteotomy: a case report.

    PubMed

    Raghoebar, Gerry M; Visser, Anita; Vissink, Arjan

    2005-01-01

    A mandibular overdenture supported by 2 or 4 endosseous implants has been proven to be a reliable treatment modality for patients suffering from conventional denture problems. However, fabrication of an implant-retained mesostructure to support an overdenture is not possible in all cases. Malpositioning of implants is a common cause of failure in such cases. A case is presented in which a ball attachment caused pain and severe swelling of the floor of the mouth because of the lingual inclination of an endosseous implant. The lingual inclination of the implant was corrected by a segmental osteotomy. Six weeks later, prosthodontic treatment began, and the resultant overdenture supported by a Dolder bar was quite acceptable for the patient.

  8. Elective implantation of covered stents for coarctation and recoarctation in adolescents and adults.

    PubMed

    Alcibar, Juan; Blanco, Roberto; Fernandez, Luis; Arriola, Josune; Garcia, Koldobika; Peña, Natividad; Inguanzo, Ramón; Voces, Roberto; Castellanos, Enrique; Montes, Pedro M

    2013-06-01

    Stent implantation is an effective therapy for aortic coarctation and recoarctation. However, in adolescents and adults, aortic wall rupture and dissection can occur, as well as aneurysms during follow-up. In order to reduce these complications, we electively implant covered stents. Since 2005, we have performed the procedure using femoral access in 17 patients (2 adolescents and 15 adults), 16 electively and 1 as a rescue procedure. We used the Mullins technique in all cases, implanting a NuMED(®) covered stent. Good stent apposition was achieved in all 17 procedures; 8 patients required a distal flare. Gradient was reduced from 40 (16) mmHg to 2 (2) mmHg (P<.001) and lumen diameter increased from 4 (2) mm to 19 (3) mm (P<.001). Two exceptional cases are discussed: one patient with aortic wall rupture who underwent a rescue procedure using a stent within a covered stent and another patient with total obstruction and intercostal aneurysm in whom the outcome was fatal at 48 h postprocedure (autopsy is shown). Four-year clinical follow-up included Doppler echocardiography; an additional imaging technique was required in 13 patients. All patients recovered well and there were no complications. Covered stents are effective in treating coarctation and recoarctation in adolescents and adults, are the treatment of choice in patients with complex anatomy, and must be available in the operating room as a rescue device when implanting a conventional stent. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  9. Determining factors for implant referral rates.

    PubMed

    Levin, Roger P

    2002-01-01

    The research findings indicate that the field of implant dentistry will only grow at a moderately low level unless certain changes are made. Findings indicated that the effort by the implant companies has been nothing short of dramatic, and yet almost 60% of restorative doctors do not participate annually in any implant case. There was no clear indication that younger restorative doctors will significantly increase the number of implant referrals, as their overall implant education has not dramatically differed from those dentists who graduated in earlier years. Once the research was completed, it became obvious to Levin Group that the driving force behind implant referral growth will be implant surgeons, because of their one-to-one relationship with restorative doctors. The Levin Group Implant Management and Marketing Consulting Program is based on approaching restorative doctors in several different levels, starting with awareness all the way through to case facilitation and long-term tracking and communication. Finally, a continuing marketing/education effort needs to be consistently in place with effective materials, not only to create a high level of awareness, but also to motivate restorative doctors to refer cases and then work through the case with the implant surgeon to a satisfactory completion for the restorative doctor, implant surgeon, and patient. While the surgical insertion of implants may seem to carry a high-profit margin relative to the restoration of implants, the truth is that the restoration of implants usually provides a 40% higher profit margin for the restorative doctor than traditional dental services. One of the key issues is that referring doctors have not necessarily learned how to set fees and present cases with regard to implant dentistry. The key factor here is to ensure that the patient understands that implant services involve higher fees than traditional services, because of the necessarily higher levels of experience, education, and cost associated with implant dentistry. It is also important to emphasize to patients that the quality of life far outweighs the differential in fees.

  10. [Pre-operation evaluation and intra-operation management of cochlear implantation].

    PubMed

    Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning

    2004-10-01

    To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.

  11. The dynamic natures of implant loading.

    PubMed

    Wang, Rui-Feng; Kang, Byungsik; Lang, Lisa A; Razzoog, Michael E

    2009-06-01

    A fundamental problem in fully understanding the dynamic nature of implant loading is the confusion that exists regarding the torque load delivered to the implant complex, the initial force transformation/stress/strain developed within the system during the implant complex assembly, and how the clamping forces at the interfaces and the preload stress impact the implant prior to any external loading. The purpose of this study was to create an accurately dimensioned finite element model with spiral threads and threaded bores included in the implant complex, positioned in a bone model, and to determine the magnitude and distribution of the force transformation/stress/strain patterns developed in the modeled implant system and bone and, thus, provide the foundational data for the study of the dynamic loading of dental implants prior to any external loading. An implant (Brånemark Mark III), abutment (CeraOne), abutment screw (Unigrip), and the bone surrounding the implant were modeled using HyperMesh software. The threaded interfaces between screw/implant and implant/bone were designed as a spiral thread helix assigned with specific coefficient of friction values. Assembly simulation using ABAQUS and LS-DYNA was accomplished by applying a 32-Ncm horizontal torque load on the abutment screw (Step 1), then decreasing the torque load to 0 Ncm to simulate the wrench removal (Step 2). The postscript data were collected and reviewed by HyperMesh. A regression analysis was used to depict the relationships between the torque load and the mechanical parameters. During the 32-Ncm tightening sequence, the abutment screw elongated 13.3 mum. The tightening torque generated a 554-N clamping force at the abutment/implant interface and a 522-N preload. The von Mises stress values were 248 MPa in the abutment at the abutment-implant interface, 765 MPa at the top of the screw shaft, 694 MPa at the bottom of the screw shaft, 1365 MPa in the top screw thread, and 21 MPa in the bone at the top of the implant-bone interface. This study also identified various characteristic isosurface stress patterns. The maximum stress magnitude to complete the von Mises stress joint pattern in the present model was 107 MPa during screw tightening, and was reduced to 104 MPa with removal of the wrench. Various specific stress patterns were identified within all elements of the implant complex during the assembly simulation. During the torque moment application, the abutment screw was elongated, and every 1.0-mum elongation of the screw was equivalent to a 47.9-N increase of the preload in the implant complex. The ideal index to determine the preload amount was the contact force at the interface between the screw threads and the threaded screw bore. The isosurface mode identified various characteristic stress patterns developed within the implant complex at the various interfaces during the assembly simulation. These patterns are the (1) spiral and ying-yang pattern of the XY stress, (2) spring, cap, clamping, and preload pattern of the ZZ stress, and (3) bone holding and joint pattern of the von Mises stress.

  12. Cranioplasty with individual carbon fibre reinforced polymere (CFRP) medical grade implants based on CAD/CAM technique.

    PubMed

    Saringer, W; Nöbauer-Huhmann, I; Knosp, E

    2002-11-01

    The authors present a new method for the reconstruction of large or complex-formed cranial bone defects using prefabricated, computer-generated, individual CFRP (carbon fibre reinforced plastics) medical grade implants. CFRP is a composite material containing carbon fibres embedded in an epoxy resin matrix. It is radiolucent, heat-resistant, extremely strong and light (its weight is 20% that of steel), has a modulus of elasticity close to that of bone, and an established biocompatibility. The utilisation of a CAD/CAM (computer aided design/computer aided manufacture) technique based on digitised computed tomography (CT) data, with stereolithographic modelling as intermediate step, enabled the production of individual, prefabricated CFRP medical grade implants with an arithmetical maximum aberration in extension of less than +/-0.25 mm. Between 1995 and February 2002, 29 patients (15 men and 14 women; mean age, 39.9 years; range, 16 to 67 years) underwent cranioplasty with CFRP medical grade implants at the neurosurgical department of the University of Vienna. Twenty-four patients were repaired secondarily (delayed cranioplasty) while 5 were repaired immediately following craniectomy (single stage cranioplasty). All cases were assessed for the accuracy of the intra-operative fit of the implant, restoration of the natural skull contour and aesthetics and adverse symptoms. The intra-operative fit was excellent in 93.1% and good in 6.9% of the implants. In two cases minor adjustments of the bony margin of the defect were required. The operating time for insertion ranged from 16 to 38 minutes, median 21 minutes. Postoperatively, 86.2% of the patients graded the restoration of their natural skull shape and symmetry as excellent while 13.8% termed it good. In one patient a non-space occupying subdural hygroma was found at the follow-up, but required no intervention. Two patients experienced atrophy of the frontal portion of the temporal muscle while one patient had a transient palsy of the frontal branch of the facial nerve. Over the mean follow-up period of 3.3 years (range, 0.08 to 6.8 years), there were no adverse reactions and no plate had to be removed. Individual, prefabricated CFRP medical grade implants may be considered as an alternative to conventionally utilised materials for cranioplasty, in particular in the challenging group of patients with extensive cranial defects or more complex-formed defects of the fronto-orbital or temporo-zygomatic region, guaranteeing short operating times and excellent functional and aesthetic results, which justifies the expense of their production.

  13. A trabecular metal implant 4 months after placement: clinical-histologic case report.

    PubMed

    Spinato, Sergio; Zaffe, Davide; Felice, Pietro; Checchi, Luigi; Wang, Hom-Lay

    2014-02-01

    The aim of this case report was to histologically evaluate the behavior of a trabecular metal (TM) implant composed of titanium and spatial 3-dimensional tantalum (Ta) trabeculae. This study is the first human histologic case report of this implant. A TM implant was placed in a 54-year-old woman exhibiting moderate chronic periodontitis. After periodontal treatment, the implant was inserted under favorable clinical conditions. Patient was not seen for 4 months because of unrelated breast reduction surgery. At the surgical reopening, periimplant inflammation affecting the coronal third of the implant was observed 4 months after implant placement. With patient's consent, the implant was removed for histologic analysis. Histology highlighted a greater amount of bone in close contact with Ta trabeculae than titanium surfaces. The finding of bone formation around the Ta trabeculae suggests that trabecular metal material promotes bone ingrowth for secondary implant stability. Additional evidence is needed to confirm this observation.

  14. Carbon and metal-carbon implantations into tool steels for improved tribological performance

    NASA Astrophysics Data System (ADS)

    Hirvonen, J.-P.; Harskamp, F.; Torri, P.; Willers, H.; Fusari, A.; Gibson, N.; Haupt, J.

    1997-05-01

    The high-fluence implantation of carbon and dual implantations of metal-metalloid pairs into steels with different microstructures are briefly reviewed. A previously unexamined system, the implantation of Si and C into two kinds of tool steels, M3 and D2, have been studied in terms of microstructure and tribological performance. In both cases ion implantation transfers a surface into an amorphous layer. However, the tribological behavior of these two materials differs remarkably: in the case of ion-implanted M3 a reduction of wear in a steel pin is observed even at high pin loads, whereas in the case of ion-implanted D2 the beneficial effects of ion implantation were limited to the lowest pin load. The importance of an initial phase at the onset of sliding is emphasized and a number of peculiarities observed in ion-implanted M3 steel are discussed.

  15. Dental rehabilitation using an implant-carrying plate system in a severely resorbed edentulous maxilla: a case report.

    PubMed

    Kurita, Hiroshi; Sakai, Hironori; Uehara, Shinobu; Kurashina, Kenji

    2008-01-01

    This clinical article describes a case of dental rehabilitation using an implant-carrying plate system (EPITEC) for a patient with severely resorbed edentulous maxilla and microstomia. In this case, the presence of microstomia prevented bone augmentation procedures through an intraoral approach. Treatment using 2 endosseous implants inserted in the canine regions and an implant-supported overdenture was planned. However, endosseous implants were not feasible on the right side because of insufficient available bone volume. An implant-carrying plate system was then utilized on the right side. Four months later, an implant-supported ball-attachment overdenture was fabricated. At the 2-year follow-up, the clinical course remained uneventful, and the patient remained satisfied with the treatment.

  16. A prospective study on silicone breast implants and the silicone-related symptom complex.

    PubMed

    Contant, C M E; Swaak, A J G; Obdeijn, A I M; van der Holt, B; Tjong Joe Wai, R; van Geel, A N; Eggermont, A M M

    2002-06-01

    This cohort study prospectively evaluated the prevalence of the silicone-related symptom complex (SRSC) in relation to antinuclear antibodies (ANA) and magnetic resonance imaging (MRI) of silicone breast implants (SBI) 1 year after implantation. A total of 57 women undergoing mastectomy followed by immediate breast reconstruction (IBR) and SBI between March 1995 and March 1997 at the University Hospital Rotterdam/Daniel den Hoed Cancer Centre, were prospectively evaluated. Just before and 1 year after IBR the sera of these women were tested for the presence of ANA and they were screened for the prevalence of SRSC-related symptoms by questionnaire. All prostheses were evaluated by MRI 1 month and 1 year after IBR. Just before operation 11% of the women had a Sjögren score of more than 2, whereas 30% had such a score 1 year after IBR ( P = 0.01). One year postoperatively women had significantly more RA/Raynaud-related complaints: 21% preoperatively versus 40% 1 year after IBR ( P = 0.03). Within the undefined complaints-related group 19% had a score of 2 or more preoperatively and 33% 1 year after IBR ( P = 0.09). There were no new cases of ANA positivity 1 year after IBR. The linguine sign was seen by MRI in three implants: one 1 month after IBR and two 1 year after IBR. There was no relation to changes in SRSC expression and these MRI findings. In conclusion, 1 year after SBI implantation women had more SRSC-related complaints, especially Sjögren's and RA/Raynaud's. Moreover there was no correlation between elevated SRSC expression and changes in the presence of ANA or changes in MRI of the SBI 1 year after IBR.

  17. Hydroxyapatite-coated magnesium implants with improved in vitro and in vivo biocorrosion, biocompatibility, and bone response.

    PubMed

    Kim, Sae-Mi; Jo, Ji-Hoon; Lee, Sung-Mi; Kang, Min-Ho; Kim, Hyoun-Ee; Estrin, Yuri; Lee, Jong-Ho; Lee, Jung-Woo; Koh, Young-Hag

    2014-02-01

    Magnesium and its alloys are candidate materials for biodegradable implants; however, excessively rapid corrosion behavior restricts their practical uses in biological systems. For such applications, surface modification is essential, and the use of anticorrosion coatings is considered as a promising avenue. In this study, we coated Mg with hydroxyapatite (HA) in an aqueous solution containing calcium and phosphate sources to improve its in vitro and in vivo biocorrosion resistance, biocompatibility and bone response. A layer of needle-shaped HA crystals was created uniformly on the Mg substrate even when the Mg sample had a complex shape of a screw. In addition, a dense HA-stratum between this layer and the Mg substrate was formed. This HA-coating layer remarkably reduced the corrosion rate of the Mg tested in a simulated body fluid. Moreover, the biological response, including cell attachment, proliferation and differentiation, of the HA-coated samples was enhanced considerably compared to samples without a coating layer. The preliminary in vivo experiments also showed that the biocorrosion of the Mg implant was significantly retarded by HA coating, which resulted in good mechanical stability. In addition, in the case of the HA-coated implants, biodegradation was mitigated, particularly over the first 6 weeks of implantation. This considerably promoted bone growth at the interface between the implant and bone. These results confirmed that HA-coated Mg is a promising material for biomedical implant applications. © 2013 Wiley Periodicals, Inc.

  18. Breast implant capsule-associated squamous cell carcinoma: a report of 2 cases.

    PubMed

    Olsen, Daniel L; Keeney, Gary L; Chen, Beiyun; Visscher, Daniel W; Carter, Jodi M

    2017-09-01

    The use of prosthetic implants for breast augmentation has become commonplace. Although implants do not increase the risk of conventional mammary carcinoma, they are rarely associated with anaplastic large cell lymphoma. We report 2 cases of breast implant capsule-associated squamous cell carcinoma with poor clinical outcomes. Both patients (56-year-old woman and 81-year-old woman) had long-standing implants (>25 years) and presented with acute unilateral breast enlargement. In both cases, squamous cell carcinoma arose in (focally dysplastic) squamous epithelium-lined breast implant capsules and widely invaded surrounding breast parenchyma or chest wall. Neither patient had evidence of a primary mammary carcinoma or squamous cell carcinoma at any other anatomic site. Within 1 year, one patient developed extensive, treatment-refractory, locoregional soft tissue metastasis, and the second patient developed hepatic and soft tissue metastases and died of disease. There are 2 prior reported cases of implant-associated squamous cell carcinoma in the plastic surgery literature; one provides no pathologic staging or outcome information, and the second case was a capsule-confined squamous cell carcinoma. Together, all 4 cases share notable commonalities: the patients had long-standing breast implants and presented with acute unilateral breast pain and enlargement secondary to tumors arising on the posterior aspect of squamous epithelialized implant capsules. Because of both its rarity and its unusual clinical presentation, implant capsule-associated squamous cell carcinoma may be underrecognized. The aggressive behavior of the tumors in this series underscores the importance of excluding malignancy in patients with long-standing breast implants who present with acute unilateral breast pain and enlargement. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Customized silicone implant for the correction of acquired and congenital chest wall deformities: A valuable option with pectus excavatum.

    PubMed

    Soccorso, Giampiero; Parikh, Dakshesh H; Worrollo, Steve

    2015-07-01

    Surgical remodeling and correction of congenital and acquired chest wall deformities (CWD) is undertaken many times for cosmesis. Although reportedly minimally invasive, commonly used Nuss procedure for correction of pectus excavatum (PE) is not without complications. Nuss procedure is also not suitable for complex deformities and Poland syndrome cases. Insertion of custom-made silicone implants for the reconstruction of defects has been adopted from adult plastic reconstructive surgery as primary repair of CWD or rescue procedure for recurrence of PE after recurrence or residual deformity. We present our experience with CWD reconstruction in children with customized silicone prosthesis made from a surgically implantable liquid silicone rubber (NuSil MED-4805, Ca). Since 2006 we treated 26 patients with CWD: six were children (age <17years, median 14.6) with PE. Implants were custom made for each patient's chest. The implants were inserted under general anesthesia. Postoperatively all patients were fully satisfied with the cosmetic result and subjective patient satisfaction remained excellent at follow-up in all the children. Only one child developed postoperative complications (seroma). Customized silicone implant for PE in the pediatric age is an alternative therapeutic method, as primary or rescue treatment, with equally good cosmetic outcome, fewer significant complications, less postoperative pain and a faster recovery. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Use of mini dental implants in ectodermal dysplasia children: follow-up of three cases.

    PubMed

    Sfeir, E; Nassif, N; Moukarzel, C

    2014-07-01

    Ectodermal dysplasia is a hereditary genodermatosis characterised by a congenital defect of ectodermal structures, causing tooth malformations and anomalies. Implantology has become accepted in these subjects. However cases are often complicated by a reduction in the size of the alveolar process, making the insertion of conventional implants difficult without bone grafting. The reduced diameter of mini-implants and their ease of insertion provide an interesting solution in supporting removable or fixed prosthesis. The purpose of this paper is to report the follow-up of three cases of children (11-12 year- old) with ectodermal dysplasia in which mini-implants were used to support the prostheses. In the first case, two mini-implants were inserted into the anterior part of the mandible for stabilising a removable denture (2 years follow-up). In the other two cases, mini- implants were inserted in the maxilla and mandible to replace missing front teeth with fixed prostheses. Patients were called for follow- up every 6 months: in the sencod case follow-up lasted 4 years in the mandible and 2 years in the maxilla; in the third case, 2 years in the maxilla and 1 year in the mandible. The use of mini-implants in children with ectodermal dysplasia can enhance aesthetics, and functional and psychosocial development.

  1. Immediate Implants: Clinical Guidelines for Esthetic Outcomes

    PubMed Central

    Javaid, Mohammad A.; Khurshid, Zohaib; Zafar, Muhammad S.; Najeeb, Shariq

    2016-01-01

    Research has shown that tooth loss results in morphological changes in alveolar ridge that may influence the subsequent implant placement. Immediate implant placement was introduced as a possible means to limit bone resorption and reduce the number of surgical procedures following tooth extraction. Histological and clinical evidence from human clinical studies showing efficacy of immediate implants has come to light over the last decade or so. However, immediate implant placement is a challenging surgical procedure and requires proper case selection and surgical technique. Furthermore, there appears to be a lack of clinical guidelines for immediate implant placement case selection. Therefore, the aim of this mini-review is to analyze critical evidence from human studies in order to establish clinical guidelines which may help clinicians in case selection when considering immediate implant placement protocol. PMID:29563463

  2. [The use of Foley catheter in reconstructive procedures involving the middle third of the facial skeleton].

    PubMed

    Medvedev, Yu A; Petruk, P S; Shamanaeva, L S; Volkova, V A; Davidov, A R

    2016-01-01

    The aim of this study was to improve the efficiency of surgical treatment of patients with fractures involving zygomatico-orbital complex and maxillary sinus through the use of Foley catheter. 352 patients with fractures of the middle third of the facial skeleton were treated at the Departments of Oral & Maxillofacial Surgery in Novokuznetsk Institute and I.M. Sechenov First MSMU. All patients underwent open reduction and osteosynthesis using extramedullary titanium mini-plates and NiTi mini-clamps. In the cases with large bone defects additional reconstructive techniques were used such as replantation of bone fragments and endoprosthesis with NiTi implants. For the purpose of drainage and retention Foley catheter was placed in the cavity of the maxillary sinus after the surgical procedure. We obtained good and satisfactory results in the majority of clinical cases. The use of Foley catheter was found to be very effective for the post-operative drainage and hemostasis of the maxillary sinus and in cases involving the use of fixation implant in the reconstructive surgeries in the middle third of the face.

  3. PIP breast implant removal: a study of 828 cases.

    PubMed

    Oulharj, S; Pauchot, J; Tropet, Y

    2014-03-01

    In March, 2010, the French Health Products Safety Agency suspended the sale of prefilled silicone breast implants manufactured by Poly Implants Prosthèse Prothese (PIP) because of a high failure rate and the use of an inappropriate silicone gel that did not comply with CE marking. These findings led to an international medical crisis. In France, 30,000 female patients had PIP implants. In our Department, 1150 PIP breast implants had been implanted in 630 patients since 2001. A retrospective study was conducted to define the rupture rate of these implants and the complications that arise. The women included in the study underwent implant removal from May 2010 to September 2012 for preventive or curative reasons. Data were collected from medical records that included: results of clinical examination, breast ultrasound before removal, rates of implant rupture, results of biopsy of periprosthetic capsule and pericapsule tissue and postoperative complications. A total of 828 PIP breast implants were removed in 455 patients. The rate of ruptured implants was 7.73% (64/828), corresponding to 11.6% of patients. A periprosthetic effusion was associated with rupture in 44% of cases. Breast ultrasound indicated a rupture for 87 implants; 32% were true positives and 3% were false negatives. Periprosthetic capsule biopsy demonstrated the presence of a foreign body, which seemed to be silicone, in 26% of cases and the presence of inflammation in 13% of cases. No siliconoma-type lesion was identified in the pericapsular tissue at biopsy. A total of 14 implants presented perspiration at removal. A statistically significant difference was found between the rates of rupture for texturised implants as compared to the smooth-surfaced implants. There were eight post-revisional-surgery complications (1%) and three cases of breast adenocarcinoma. The preventive explantation of PIP breast implants is justified given the high failure rate (7.73%) and given patients' exposure to silicone gel that did not comply with CE standards in the absence of rupture, through the early perspiration of implants. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    PubMed Central

    2011-01-01

    Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast) and preoperative (radiographic template) models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology. PMID:21338504

  5. Spinal cord stimulation for FBSS and CRPS: A review of 80 cases with on-table trial of stimulation.

    PubMed

    Gopal, Hari; Fitzgerald, Joseph; McCrory, Connail

    2016-01-01

    Spinal cord stimulation (SCS) is used for the treatment of chronic neuropathic pain, a notoriously difficult condition to treat. Failed Back Surgery Syndrome (FBSS) and Complex Regional Pain syndrome (CRPS) remain the strongest indications. Funding remains a difficult issue and the use of trial of stimulation is the traditional method of ensuring best outcomes from implantation. A retrospective and consecutive review of 80 cases of spinal cord stimulation for patients with a diagnosis of FBSS and CRPS having undergone prior comprehensive medical management and interventional treatment with no sustained benefit. Trial of stimulation was performed on-table and if acceptable coverage was achieved, the case proceeded to full implantation. The mean patient age was 50.08 years (range 28-80 years). At 12 months follow-up, thirty two patients (40%) no longer required analgesic medication. Thirty patients (37.5%) reported their pain was manageable with first line analgesics. Fourteen (17.5%) reported their pain was manageable first line analgesic and occasional tramadol or codeine. Four (5%) reported that their pain was manageable with NSAID's, paracetamol, amitriptyline, and regular codeine or tramadol. Seventeen out of eighty patients (21.25%) were unemployed before SCS implant, and at 12 months follow up eight of these patients (47.05%) had returned to work. There was no infective complications or explants. Two patients (2.53%) required one lead revision, which was successful. SCS is the most effective treatment for FBSS and CRPS, which is proven resistant to medical management. On-table trial and implantation is easy to perform with good success rate and low morbidity and if successful will reduce complication rates, especially infection.

  6. Porous and nonporous orbital implants for treating the anophthalmic socket: A meta-analysis of case series studies.

    PubMed

    Schellini, Silvana; Jorge, Eliane; Sousa, Roberta; Burroughs, John; El-Dib, Regina

    2016-01-01

    To assess the efficacy and safety of porous and nonporous implants for management of the anophthalmic socket. Case series meta-analysis was conducted with no language restriction, including studies from: PUBMED, EMBASE and LILACS. Study eligibility criteria were case series design with more than 20 cases reported, use of porous and/or nonporous orbital implants, anophthalmic socket and, treatment success defined as no implant exposure or extrusion. Complications rates from each included study were quantified. Proportional meta-analysis was performed on both outcomes with a random-effects model and the 95% confidential intervals were calculated. A total of 35 case series studies with a total of 3,805 patients were included in the meta-analysis. There are no studies comparing porous and nonporous implants in the anophthalmic socket treatment. There was no statistically significant difference between porous polyethylene (PP) and hydroxyapatite (HA) on implant exposure: 0.026 (0.012-0.045) vs 0.054 (0.041-0.070), respectively and, neither on implant extrusion: 0.0042 (0.0008-0.010) vs. 0.018 (0.004-0.042), respectively. However, there was a significant difference supporting the use of PP when compared to bioceramic implant: 0.026 (0.012 -0.045) vs. 0.12 (0.06-0.20), respectively, on implant exposure. PP implants showed lower chance of exposure than bioceramic implant for anophthalmic socket reconstruction, although we cannot rule out the possibility of heterogeneity bias due to the nature and level of evidence of the included studies. Clinical trials are necessary to expand the knowledge of porous and nonporous orbital implants in the anophthalmic socket management.

  7. Rotational Flap to Enhance Buccal Gingival Thickness and Implant Emergence Profile in the Esthetic Zone: Two Cases Reports

    PubMed Central

    AL-Juboori, Mohammed Jasim

    2017-01-01

    Objective: Many techniques have been developed to enhance the gingival thickness, gingival level and emergence profile around the implant in the esthetic zone. Introduction: In this study, a buccal rotational flap was used to improve the implant site in the esthetic zone and increase gingival tissue thickness. Methods: Two cases involved the use of a rotational flap during second-stage implant surgery, one case involved the use of a temporary crown with a healing abutment, and another case involved the use of a healing abutment. Result: The cases were followed up until the final crown was placed. The implant site was improved in 2 cases; the gingival thickness increased, the gingival level was enhanced and the emergence profile was developed. Conclusion: Many factors affect the results of a rotational flap; some factors are surgical, while others are prosthetic, biological and anatomical. PMID:28839477

  8. Clinical outcomes of totally implantable venous access port placement via the axillary vein in patients with head and neck malignancy.

    PubMed

    Hong, Sun; Seo, Tae-Seok; Song, Myung Gyu; Seol, Hae-Young; Suh, Sang Il; Ryoo, In-Seon

    2018-06-01

    To evaluate the clinical outcomes and complications of totally implantable venous access port implantation via the axillary vein in patients with head and neck malignancy. A total of 176 totally implantable venous access ports were placed via the axillary vein in 171 patients with head and neck malignancy between May 2012 and June 2015. The patients included 133 men and 38 women, and the mean age was 58.8 years (range: 19-84 years). Medical records were retrospectively reviewed. This study included a total of 93,237 totally implantable venous access port catheter-days (median 478 catheter-days, range: 13-1380 catheter-days). Of the 176 implanted totally implantable venous access port, complications developed in nine cases (5.1%), with the overall incidence of 0.097 events/1000 catheter-days. The complications were three central line-associated blood-stream infection cases, one case of keloid scar at the needling access site, and five cases of central vein stenosis or thrombosis on neck computed tomography images. The 133 cases for which neck computed tomography images were available had a total of 59,777 totally implantable venous access port catheter-days (median 399 catheter-days, range: 38-1207 catheter-days). On neck computed tomography evaluation, the incidence of central vein stenosis or thrombosis was 0.083 events/1000 catheter-days. Thrombosis developed in four cases, yielding an incidence of 0.067 events/1000 catheter-days. All four patients presented with thrombus in the axillary or subclavian vein. Stenosis occurred in one case yielding an incidence of 0.017 events/1000 catheter-days. One case was catheter-related brachiocephalic vein stenosis, and the other case was subclavian vein stenosis due to extrinsic compression by tumor progression. Of the nine complication cases, six underwent port removal. These data indicate that totally implantable venous access port implantation via the axillary vein in patients with head and neck malignancy is safe and feasible, with a low axillary vein access-related complication rate.

  9. Sequential Bilateral Cochlear Implantation in a Patient with Bilateral Meniere’s Disease

    PubMed Central

    Holden, Laura K.; Neely, J. Gail; Gotter, Brenda D.; Mispagel, Karen M.; Firszt, Jill B.

    2012-01-01

    This case study describes a 45 year old female with bilateral, profound sensorineural hearing loss due to Meniere’s disease. She received her first cochlear implant in the right ear in 2008 and the second cochlear implant in the left ear in 2010. The case study examines the enhancement to speech recognition, particularly in noise, provided by bilateral cochlear implants. Speech recognition tests were administered prior to obtaining the second implant and at a number of test intervals following activation of the second device. Speech recognition in quiet and noise as well as localization abilities were assessed in several conditions to determine bilateral benefit and performance differences between ears. The results of the speech recognition testing indicated a substantial improvement in the patient’s ability to understand speech in noise and her ability to localize sound when using bilateral cochlear implants compared to using a unilateral implant or an implant and a hearing aid. In addition, the patient reported considerable improvement in her ability to communicate in daily life when using bilateral implants versus a unilateral implant. This case suggests that cochlear implantation is a viable option for patients who have lost their hearing to Meniere’s disease even when a number of medical treatments and surgical interventions have been performed to control vertigo. In the case presented, bilateral cochlear implantation was necessary for this patient to communicate successfully at home and at work. PMID:22463939

  10. Complications leading to surgical revision in implantable cardioverter defibrillator patients: comparison of patients with single-chamber, dual-chamber, and biventricular devices.

    PubMed

    Duray, Gabor Z; Schmitt, Joern; Cicek-Hartvig, Sule; Hohnloser, Stefan H; Israel, Carsten W

    2009-03-01

    Implantable cardioverter defibrillator (ICD) technology has become more complex, particularly with respect to biventricular resynchronization devices. The incidence of hardware-related complications in single (SC)-, dual (DC)-, and triple (BiV)-chamber devices requiring surgical revision has not been investigated systematically. We analysed data from consecutive ICD recipients implanted between January 2000 and December 2007 with respect to the need of surgical re-intervention for device- or lead-related complications. Generator exchanges due to normal battery depletion were not considered. From 816 patients (81% male, 69% ischaemic cardiomyopathy, 48% secondary prevention ICDs) followed for 31 +/- 24 months (2118 cumulative patient-years), 98 patients underwent 110 revisions (5.2% per patient-year). Complications included lead-related revision procedures in 81 cases and generator-related problems in 29 cases. The annual incidence of surgical revision due to complications was 11.8% in BiV compared with 4.9% in SC and 4.1% in DC patients (P = 0.002). This higher revision rate was mainly caused by lead-related complications. Implantation of a BiV system was an independent risk factor of the need for surgical revision (relative risk 2.37, 95% confidence interval 1.38-4.04). Even with long-lasting operator experience, complications requiring surgical revision remain a clinically important problem of ICD therapy. The incidence of complications is significantly higher in BiV resynchronization devices than in SC and DC systems.

  11. The interference of electronic implants in low frequency electromagnetic fields.

    PubMed

    Silny, J

    2003-04-01

    Electronic implants such as cardiac pacemakers or nerve stimulators can be impaired in different ways by amplitude-modulated and even continuous electric or magnetic fields of strong field intensities. For the implant bearer, possible consequences of a temporary electromagnetic interference may range from a harmless impairment of his well-being to a perilous predicament. Electromagnetic interferences in all types of implants cannot be covered here due to their various locations in the body and their different sensing systems. Therefore, this presentation focuses exemplarily on the most frequently used implant, the cardiac pacemaker. In case of an electromagnetic interference the cardiac pacemaker reacts by switching to inhibition mode or to fast asynchronous pacing. At a higher disturbance voltage on the input of the pacemaker, a regular asynchronous pacing is likely to arise. In particular, the first-named interference could be highly dangerous for the pacemaker patient. The interference threshold of cardiac pacemakers depends in a complex way on a number of different factors such as: electromagnetic immunity and adjustment of the pacemaker, the composition of the applied low-frequency fields (only electric or magnetic fields or combinations of both), their frequencies and modulations, the type of pacemaker system (bipolar, unipolar) and its location in the body, as well as the body size and orientation in the field, and last but not least, certain physiological conditions of the patient (e.g. inhalation, exhalation). In extensive laboratory studies we have investigated the interference mechanisms in more than 100 cardiac pacemakers (older types as well as current models) and the resulting worst-case conditions for pacemaker patients in low-frequency electric and magnetic fields. The verification of these results in different practical everyday-life situations, e.g. in the fields of high-voltage overhead lines or those of electronic article surveillance systems is currently in progress. In case of the vertically-oriented electric 50 Hz fields preliminary results show that per 1 kV/m unimpaired electrical field strength (rms) an interference voltage of about 400 microVpp as worst-case could occur at the input of a unipolar ventricularly controlled, left-pectorally implanted cardiac pacemaker. Thus, already a field strength above ca. 5 kV/m could cause an interference with an implanted pacemaker. The magnetic fields induces an electric disturbance voltage at the input of the pacemaker. The body and the pacemaker system compose several induction loops, whose induced voltages rates add or subtract. The effective area of one representing inductive loop ranges from 100 to 221 cm2. For the unfavourable left-pectorally implantated and atrially-controlled pacemaker with a low interference threshold, the interference threshold ranges between 552 and 16 microT (rms) for magnetic fields at frequencies between 10 and 250 Hz. On this basis the occurrence of interferences with implanted pacemakers is possible in everyday-life situations. But experiments demonstrate a low probability of interference of cardiac pacemakers in practical situations. This apparent contradiction can be explained by a very small band of inhibition in most pacemakers and, in comparison with the worst-case, deviating conditions.

  12. Failing left ventricle to ascending aorta conduit-Hybrid implantation of a melody valve and NuMed covered stent.

    PubMed

    Gössl, Mario; Johnson, Jonathan N; Hagler, Donald J

    2014-04-01

    We present the case of a 36-year-old woman with increasing shortness of breath, a new 3/4 diastolic murmur, and a complex history of LV outflow tract obstruction. She has undergone multiple surgeries including the replacement of her old LV apex to ascending aorta conduit with a 20-mm Gore-Tex tube graft, addition of a 24-mm homograft sutured between the conduit and the LV apex, and insertion of a 21-mm Freestyle porcine valve conduit between the Gore-Tex tube graft and allograft at age 23. The current assessment showed a failing Freestyle conduit prosthesis leading to left heart decompensation. Due to substantial surgical risk, the patient underwent successful implantation of a Melody valve into the Gore-Tex tube and exclusion of the failing Freestyle bioprosthesis with a NuMed CP stent in a hybrid procedure. The case nicely illustrates the collaborative potential of cardiovascular surgeons and interventional cardiologists in the new arena of a hybrid operating room. Complex hybrid procedures like the current one, especially those including percutaneous placements of valves, offer therapeutic options for patients that are otherwise too high risk for conventional open heart surgery. Copyright © 2013 Wiley Periodicals, Inc.

  13. Sporotrichin Skin Test for the Diagnosis of Sporotrichosis.

    PubMed

    Bonifaz, Alexandro; Toriello, Conchita; Araiza, Javier; Ramírez-Soto, Max C; Tirado-Sánchez, Andrés

    2018-05-09

    Sporotrichosis is the most common implantation mycosis caused by several species of the Sporothrix schenckii complex. The gold standard for diagnosis is concerned with the isolation of the fungus; although, fresh examinations, staining, and biopsies are also helpful for this purpose. The sporotrichin is an antigenic complex comprised of a peptide-rhamnomannan, which is relevant with respect to pathogenic fungi; it is primarily used for serological and skin testing. We present a study regarding the use of sporotrichin as a diagnostic aid for cutaneous sporotrichosis. Furthermore, 138 cases with suspicion of sporotrichosis were included, 55 of which were proven through cultures. Moreover, out of these 55 cases, 52 (94.5%) tested positive for sporotrichin, while the negative cases corresponded to the disseminated cutaneous forms. We observed a sensitivity of 94.5% and a specificity of 95.2%. We consider that the use of sporotrichin as a skin test helps us as an auxiliary diagnosis before a positive sample culture.

  14. Early bone anchorage to micro- and nano-topographically complex implant surfaces in hyperglycemia.

    PubMed

    Ajami, Elnaz; Bell, Spencer; Liddell, Robert S; Davies, John E

    2016-07-15

    The aim of this work was to investigate the effect of implant surface design on early bone anchorage in the presence of hyperglycemia. 108 Wistar rats were separated into euglycemic (EG) controls and STZ-treated hyperglycemic (HG) groups, and received bilateral femoral custom rectangular implants of two surface topographies: grit blasted (GB) and grit-blast with a superimposed calcium phosphate nanotopography (GB-DCD). The peri-implant bone was subjected to a tensile disruption test 5, 7, and 9days post-operatively (n=28/time point); the force was measured; and the residual peri-implant bone was observed by scanning electron microscopy (SEM). Disruption forces at 5days were not significantly different from zero for the GB implants (p=0.24) in either metabolic group; but were for GB+DCD implants in both metabolic groups (p<0.001). Contact osteogenesis was greater on GB-DCD than the GB surface. The nano-and micro-surfaced implants showed significantly different disruption forces at all time points (e.g. >15N and <5N respectively at 9days). Such differences were not seen within the GB implants, as all values were very low (<5N). Even in hyperglycemia the GB-DCD surface outperformed the GB surfaces in both metabolic groups. Significantly, SEM of peri-implant bone showed compromised intra-fibrillar collagen mineralization in hyperglycemia, while inter-fibrillar and cement line mineralization remained unaffected. Enhanced bone anchorage to the implant surfaces was observed on the nanotopographically complex surface independent of metabolic group. The compromised intra-fibrillar mineralization observed provides a mechanism by which early bone mineralization is affected in hyperglycemia. It is generally accepted that the hyperglycemia associated with diabetes mellitus compromises bone quality, although the mechanism by which this occurs is unknown. Uncontrolled hyperglycemia is therefore a contra-indication for bone implant placement. It is also known that nano-topographically complex implant surfaces accelerate early peri-implant healing. In this report we show that, in our experimental model, nano-topographically complex surfaces can mitigate the compromised bone healing seen in hyperglycemia. Importantly, we also provide a mechanistic explanation for compromised bone quality in hyperglycemia. We show that intra-fibrillar collagen mineralization is compromised in hyperglycemia, but that interfibrillar and cement line mineralization, remain unaffected. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  15. Initial experience of subcutaneous implantable cardioverter defibrillators in Singapore: a case series and review of the literature

    PubMed Central

    Lim, Tien Siang Eric; Tan, Boon Yew; Ho, Kah Leng; Lim, Chuh Yih Paul; Teo, Wee Siong; Ching, Chi-Keong

    2015-01-01

    Transvenous implantable cardioverter defibrillators are a type of implantable cardiac device. They are effective at reducing total and arrhythmic mortality in patients at risk of sudden cardiac death. Subcutaneous implantable cardioverter defibrillators (S-ICDs) are a new alternative that avoids the disadvantages of transvenous lead placement. In this case series, we report on the initial feasibility and safety of S-ICD implantation in Singapore. PMID:26512151

  16. Initial experience of subcutaneous implantable cardioverter defibrillators in Singapore: a case series and review of the literature.

    PubMed

    Lim, Tien Siang Eric; Tan, Boon Yew; Ho, Kah Leng; Lim, Chuh Yih Paul; Teo, Wee Siong; Ching, Chi-Keong

    2015-10-01

    Transvenous implantable cardioverter defibrillators are a type of implantable cardiac device. They are effective at reducing total and arrhythmic mortality in patients at risk of sudden cardiac death. Subcutaneous implantable cardioverter defibrillators (S-ICDs) are a new alternative that avoids the disadvantages of transvenous lead placement. In this case series, we report on the initial feasibility and safety of S-ICD implantation in Singapore.

  17. Experimental identification of nitrogen-vacancy complexes in nitrogen implanted silicon

    NASA Astrophysics Data System (ADS)

    Adam, Lahir Shaik; Law, Mark E.; Szpala, Stanislaw; Simpson, P. J.; Lawther, Derek; Dokumaci, Omer; Hegde, Suri

    2001-07-01

    Nitrogen implantation is commonly used in multigate oxide thickness processing for mixed signal complementary metal-oxide-semiconductor and System on a Chip technologies. Current experiments and diffusion models indicate that upon annealing, implanted nitrogen diffuses towards the surface. The mechanism proposed for nitrogen diffusion is the formation of nitrogen-vacancy complexes in silicon, as indicated by ab initio studies by J. S. Nelson, P. A. Schultz, and A. F. Wright [Appl. Phys. Lett. 73, 247 (1998)]. However, to date, there does not exist any experimental evidence of nitrogen-vacancy formation in silicon. This letter provides experimental evidence through positron annihilation spectroscopy that nitrogen-vacancy complexes indeed form in nitrogen implanted silicon, and compares the experimental results to the ab initio studies, providing qualitative support for the same.

  18. Intraoperative Comparison of Anatomical versus Round Implants in Breast Augmentation: A Randomized Controlled Trial.

    PubMed

    Hidalgo, David A; Weinstein, Andrew L

    2017-03-01

    The purpose of this randomized controlled trial was to determine whether anatomical implants are aesthetically superior to round implants in breast augmentation. Seventy-five patients undergoing primary breast augmentation had a round silicone implant of optimal volume, projection, and diameter placed in one breast and an anatomical silicone device of similar volume and optimal shape placed in the other. After intraoperative photographs were taken, the anatomical device was replaced by a round implant to complete the procedure. A survey designed to measure breast aesthetics was administered to 10 plastic surgeon and 10 lay reviewers for blind evaluation of the 75 cases. No observable difference in breast aesthetics between anatomical and round implants was reported by plastic surgeons in 43.6 percent or by lay individuals in 29.2 percent of cases. When a difference was perceived, neither plastic surgeons nor lay individuals preferred the anatomical side more often than the round side. Plastic surgeons judged the anatomical side superior in 51.1 percent of cases and the round side superior in 48.9 percent of cases (p = 0.496). Lay individuals judged the anatomical side superior in 46.7 percent of cases and the round side superior in 53.3 percent (p = 0.140). Plastic surgeons identified implant shape correctly in only 26.5 percent of cases. This study provides high-level evidence supporting no aesthetic superiority of anatomical over round implants. Given that anatomical implants have important and unique disadvantages, a lack of proven aesthetic superiority argues against their continued use in breast augmentation. Therapeutic, I.

  19. Ross filter pairs for metal artefact reduction in x-ray tomography: a case study based on imaging and segmentation of metallic implants

    NASA Astrophysics Data System (ADS)

    Arhatari, Benedicta D.; Abbey, Brian

    2018-01-01

    Ross filter pairs have recently been demonstrated as a highly effective means of producing quasi-monoenergetic beams from polychromatic X-ray sources. They have found applications in both X-ray spectroscopy and for elemental separation in X-ray computed tomography (XCT). Here we explore whether they could be applied to the problem of metal artefact reduction (MAR) for applications in medical imaging. Metal artefacts are a common problem in X-ray imaging of metal implants embedded in bone and soft tissue. A number of data post-processing approaches to MAR have been proposed in the literature, however these can be time-consuming and sometimes have limited efficacy. Here we describe and demonstrate an alternative approach based on beam conditioning using Ross filter pairs. This approach obviates the need for any complex post-processing of the data and enables MAR and segmentation from the surrounding tissue by exploiting the absorption edge contrast of the implant.

  20. Linked shoulder replacement: current design problems and a new design proposal.

    PubMed

    Mohammed, Ali Abdullah; Frostick, Simon Peter

    2016-04-01

    Totally constrained shoulder replacement with linked components is one of the surgical options in post-tumor resection shoulder reconstruction or in complex shoulder revision operations. In this paper, we intend to shed light on such an implant design, which provides a linked constrained connection between the humeral head and the glenoid, and to show some immediate postoperative complications, implant progression to decrease the chances of implant mechanical postinsertion failure, and a new design proposal. In our center, we use the linked prosthesis in complex revision situations; however, there have been some complications, which could be attributed mainly to the engineering and the implant design, and hence potentially avoidable by making a different design to cover for those mechanical issues. Two such complications are described in this paper. Early revisions after linked shoulder replacement implantation were needed in two occasions due to implant disconnection: one of them was due to dislodgement from the native glenoid, and the second one was due to the disengagement of the ringlet which secures the linkage mechanism between the humeral head and the implanted glenoid shell. There is a need for a more stable design construct to avoid the reported complications that needed early revision surgeries. The new design proposed is an attempt to help providing a better and more stable implant to decrease the chances of revision in those complex situations where the patient already had many major operations, and working to increase the durability of the implant is crucial.

  1. A Novel Treatment Decision Tree and Literature Review of Retrograde Peri-Implantitis.

    PubMed

    Sarmast, Nima D; Wang, Howard H; Soldatos, Nikolaos K; Angelov, Nikola; Dorn, Samuel; Yukna, Raymond; Iacono, Vincent J

    2016-12-01

    Although retrograde peri-implantitis (RPI) is not a common sequela of dental implant surgery, its prevalence has been reported in the literature to be 0.26%. Incidence of RPI is reported to increase to 7.8% when teeth adjacent to the implant site have a previous history of root canal therapy, and it is correlated with distance between implant and adjacent tooth and/or with time from endodontic treatment of adjacent tooth to implant placement. Minimum 2 mm space between implant and adjacent tooth is needed to decrease incidence of apical RPI, with minimum 4 weeks between completion of endodontic treatment and actual implant placement. The purpose of this study is to compile all available treatment modalities and to provide a decision tree as a general guide for clinicians to aid in diagnosis and treatment of RPI. Literature search was performed for articles published in English on the topic of RPI. Articles selected were case reports with study populations ranging from 1 to 32 patients. Any case report or clinical trial that attempted to treat or rescue an implant diagnosed with RPI was included. Predominant diagnostic presentation of a lesion was presence of sinus tract at buccal or facial abscess of apical portion of implant, and subsequent periapical radiographs taken demonstrated a radiolucent lesion. On the basis of case reports analyzed, RPI was diagnosed between 1 week and 4 years after implant placement. Twelve of 20 studies reported that RPI lesions were diagnosed within 6 months after implant placement. A step-by-step decision tree is provided to allow clinicians to triage and properly manage cases of RPI on the basis of recommendations and successful treatments provided in analyzed case reports. It is divided between symptomatic and asymptomatic implants and adjacent teeth with vital and necrotic pulps. Most common etiology of apical RPI is endodontic infection from neighboring teeth, which was diagnosed within 6 months after implant placement. Most common findings, radiographically and clinically, are lesions around implant apex and sinus tract. A small number of implants did not improve with treatment. Decision tree provides a path to diagnose and treat lesions to facilitate their management. Further studies are needed to focus on histologic data around periapical microbiota to establish specific etiology and differential diagnoses compared with marginal peri-implantitis and other implant-related conditions.

  2. A rare, late complication after automated implantable cardioverter-defibrillator placement.

    PubMed

    Shapiro, Michael; Hanon, Sam; Schweitzer, Paul

    2004-10-01

    This article describes an interesting case of automated implantable cardioverter defibrillator (AICD) extrusion fifteen months after implantation. The case report is followed by a discussion of the causes and treatment of skin erosion following pacemaker/AICD insertion.

  3. Considerations for Pediatric Cochlear Implant Recipients With Unilateral or Asymmetric Hearing Loss: Assessment, Device Fitting, and Habilitation.

    PubMed

    Greaver, Laura; Eskridge, Hannah; Teagle, Holly F B

    2017-06-13

    The purpose of this clinical report is to present case studies of children who are nontraditional candidates for cochlear implantation because they have significant residual hearing in 1 ear and to describe outcomes and considerations for their audiological management and habilitation. Case information is presented for 5 children with profound hearing loss in 1 ear and normal or mild-to-moderate hearing loss in the opposite ear and who have undergone unilateral cochlear implantation. Pre- and postoperative assessments were performed per typical clinic routines with modifications described. Postimplant habilitation was customized for each recipient using a combination of traditional methods, newer technologies, and commercial materials. The 5 children included in this report are consistent users of their cochlear implants and demonstrate speech recognition in the implanted ear when isolated from the better hearing ear. Candidacy criteria for cochlear implantation are evolving. Children with single-sided deafness or asymmetric hearing loss who have traditionally not been considered candidates for cochlear implantation should be evaluated on a case-by-case basis. Audiological management of these recipients is not vastly different compared with children who are traditional cochlear implant recipients. Assessment and habilitation techniques must be modified to isolate the implanted ear to obtain accurate results and to provide meaningful therapeutic intervention.

  4. Lymphomas Associated with Breast Implants: A Review of the Literature.

    PubMed

    Rupani, Asha; Frame, James D; Kamel, Dia

    2015-07-01

    Recently there have been concerns raised about anaplastic large cell lymphoma (ALCL) associated with breast implants. The main aim of this article was to review and analyze the published literature specifically for hematopoietic malignancies associated with breast implants and postulate a hypothesis for their etiology and pathogenesis. The PubMed database was searched using key words "lymphoma" and "breast implants" for published papers and abstracts on implant-associated hematopoietic malignancies. The authors found 83 published cases reported of lymphomas associated with breast implants in the medical literature. The reported cases involved various subtypes of lymphomas and the majority were ALCL, of which 66 were confirmed as ALK negative; however there was no association with any particular type of implant. The more aggressive cases and reported low death rate appeared to be related to the presence of breast masses at the time of presentation rather than effusion. The remaining reports were occasional case reports of T-cell lymphoma, follicular lymphoma, marginal zone B-cell lymphoma, primary effusion lymphoma and lymphoplasmacytic lymphoma. Considering the many thousands of women that have breast implants every year; the compiled data show that there is a very small risk of developing lymphoma. Increased awareness of association between implants and ALCL is needed globally and prospective patients considering breast implants should be fully informed of the risk. As the behavior of ALCL in these cases was indolent as compared with other primary breast lymphomas, it could suggest an abnormal reactive process. 3 © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  5. Immediate Functional Loading of One-Piece Zirconia Implants in a Full-Arch Maxillary Restoration: A Five-Year Case Report.

    PubMed

    Peter, Burghard

    Immediate loading has proven to be a predictable modality for restorations with titanium dental implants. An increasing number of articles indicate that zirconia implants might osseointegrate to a similar extent in this context. This 5-year case report describes an outpatient maxillary restoration with eight immediately loaded zirconia implants. Implantation followed extensive bone augmentation. At the 5-year follow-up, all implants were still well osseointegrated clinically and radiologically. No major bone loss or peri-implantitis had occurred in spite of temporary insufficient patient compliance. More research and studies are needed to confirm these results.

  6. PIP breast implants: rupture rate and correlation with breast cancer

    PubMed Central

    MOSCHETTA, M.; TELEGRAFO, M.; CORNACCHIA, I.; VINCENTI, L.; RANIERI, V.; CIRILLI, A.; RELLA, L.; IANORA, A.A. STABILE; ANGELELLI, G.

    2014-01-01

    Aim To evaluate the incidence of Poly Implant Prosthése (PIP) rupture as assessed by magnetic resonance imaging (MRI), the prevalence of the detected signs and the potential correlation with breast carcinoma. Patients and methods 67 patients with silicone breast implants and clinical indications for breast MRI were evaluated for a total of 125 implants: 40 (32%) PIP in 21 patients and 85 non-PIP in 46 patients (68%), the latest considered as control group. A 1.5-T MR imaging device was used in order to assess implant integrity with dedicated sequences and in 6 cases a dynamic study was performed for characterizing breast lesions. Two radiologists with more than 5 years’ experience in the field of MRI evaluated in consensus all MR images searching for the presence of clear signs of intra or extra-capsular implant rupture. Results 20/40 (50%) PIP implants presented signs of intra-capsular rupture: linguine sign in 20 cases (100%), tear-drop sign in 6 (30%). In 12/20 cases (60%), MRI signs of extra-capsular rupture were detected. In the control group, an intra-capsular rupture was diagnosed in 12/85 cases (14%) associated with extra-capsular one in 5/12 cases (42%). Among the six cases with suspected breast lesions, in 2/21 patients with PIP implants (10%) a breast carcinoma was diagnosed (mucinous carcinoma, n=1; invasive ductal carcinoma, n=1). In 4/46 patients (9%) with non-PIP implants, an invasive ductal carcinoma was diagnosed. Conclusion The rupture rate of PIP breast implants is significantly higher than non-PIP (50% vs 14%). MRI represents the most accurate imaging tool for evaluating breast prostheses and the linguine sign is the most common MRI sign to be searched. The incidence of breast carcinoma does not significantly differ between the PIP and non-PIP implants and a direct correlation with breast cancer can not been demonstrated. PMID:25644728

  7. PIP breast implants: rupture rate and correlation with breast cancer.

    PubMed

    Moschetta, M; Telegrafo, M; Cornacchia, I; Vincenti, L; Ranieri, V; Cirili, A; Rella, L; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To evaluate the incidence of Poly Implant Prosthése (PIP) rupture as assessed by magnetic resonance imaging (MRI), the prevalence of the detected signs and the potential correlation with breast carcinoma. 67 patients with silicone breast implants and clinical indications for breast MRI were evaluated for a total of 125 implants: 40 (32%) PIP in 21 patients and 85 non-PIP in 46 patients (68%), the latest considered as control group. A 1.5-T MR imaging device was used in order to assess implant integrity with dedicated sequences and in 6 cases a dynamic study was performed for characterizing breast lesions. Two radiologists with more than 5 years' experience in the field of MRI evaluated in consensus all MR images searching for the presence of clear signs of intra or extra-capsular implant rupture. 20/40 (50%) PIP implants presented signs of intra-capsular rupture: linguine sign in 20 cases (100%), tear-drop sign in 6 (30%). In 12/20 cases (60%), MRI signs of extra-capsular rupture were detected. In the control group, an intra-capsular rupture was diagnosed in 12/85 cases (14%) associated with extra-capsular one in 5/12 cases (42%). Among the six cases with suspected breast lesions, in 2/21 patients with PIP implants (10%) a breast carcinoma was diagnosed (mucinous carcinoma, n=1; invasive ductal carcinoma, n=1). In 4/46 patients (9%) with non-PIP implants, an invasive ductal carcinoma was diagnosed. The rupture rate of PIP breast implants is significantly higher than non-PIP (50% vs 14%). MRI represents the most accurate imaging tool for evaluating breast prostheses and the linguine sign is the most common MRI sign to be searched. The incidence of breast carcinoma does not significantly differ between the PIP and non-PIP implants and a direct correlation with breast cancer can not been demonstrated.

  8. Management of complications of cosmetic iris implants in a phakic eye: a case report and literature review.

    PubMed

    Bore, Millicent; Choudhari, Nikhil; Chaurasia, Sunita

    2018-03-21

    To report the intricacies of managing complications that arose out of cosmetic iris implants (BrightOcular) placement. Interventional case report. A thirty-year-old gentleman presented with complaint of progressive loss of vision after having cosmetic iris implant surgery to change his eye colour. He then developed raised intraocular pressures and had a right eye trabeculectomy conducted with the implants in situ. Subsequently, he had implant removal surgery because of persistent implant-associated complications. The vision was impaired due to progressive corneal oedema and glaucoma. Various considerations were taken while planning for surgical intervention because of the extensive structural damage to the anterior segment of the eye. This case report highlights that cosmetic iris implants are dangerous intraocular devices and management of the associated complications is also challenging. As these devices cause irreversible structural and functional damage, their use should be discouraged in normal eyes.

  9. Electrical properties and dielectric spectroscopy of Ar{sup +} implanted polycarbonate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chawla, Mahak, E-mail: mahak.chawla@gmail.com; Shekhawat, Nidhi; Aggarwal, Sanjeev

    2015-05-15

    The aim of the present paper is to study the effect of argon ion implantation on electrical and dielectric properties of polycarbonate. Specimens were implanted with 130 keV Ar{sup +} ions in the fluence ranging from 1×10{sup 14} to 1×10{sup 16} ions cm{sup −2}. The beam current used was ∼0.40 µA cm{sup −2}. The electrical conduction behaviour of virgin and Ar{sup +} implanted polycarbonate specimens have been studied through current-voltage (I-V characteristic) measurements. It has been observed that after implantation conductivity increases with increasing ion fluence. The dielectric spectroscopy of these specimens has been done in the frequency range of 100 kHz-100 MHz.more » Relaxation processes were studied by Cole-Cole plot of complex permittivity (real part of complex permittivity, ε′ vs. imaginary part of complex permittivity, ε″). The Cole-Cole plots have also been used to determine static dielectric constant (ε{sub s}), optical dielectric constant (ε{sub ∞}), spreading factor (α), average relaxation time (τ{sub 0}) and molecular relaxation time (τ). The dielectric behaviour has been found to be significantly affected due to Ar{sup +} implantation. The possible correlation between this behaviour and the changes induced by the implantation has been discussed.« less

  10. Risk factors for explantation due to infection after sacral neuromodulation: a multicenter retrospective case-control study.

    PubMed

    Myer, Emily N B; Petrikovets, Andrey; Slocum, Paul D; Lee, Toy Gee; Carter-Brooks, Charelle M; Noor, Nabila; Carlos, Daniela M; Wu, Emily; Van Eck, Kathryn; Fashokun, Tola B; Yurteri-Kaplan, Ladin; Chen, Chi Chiung Grace

    2018-04-07

    Sacral neuromodulation is an effective therapy for overactive bladder, urinary retention, and fecal incontinence. Infection after sacral neurostimulation is costly and burdensome. Determining optimal perioperative management strategies to reduce the risk of infection is important to reduce this burden. We sought to identify risk factors associated with sacral neurostimulator infection requiring explantation, to estimate the incidence of infection requiring explantation, and identify associated microbial pathogens. This is a multicenter retrospective case-control study of sacral neuromodulation procedures completed from Jan. 1, 2004, through Dec. 31, 2014. We identified all sacral neuromodulation implantable pulse generator implants as well as explants due to infection at 8 participating institutions. Cases were patients who required implantable pulse generator explantation for infection during the review period. Cases were included if age ≥18 years old, follow-up data were available ≥30 days after implantable pulse generator implant, and the implant was performed at the institution performing the explant. Two controls were matched to each case. These controls were the patients who had an implantable pulse generator implanted by the same surgeon immediately preceding and immediately following the identified case who met inclusion criteria. Controls were included if age ≥18 years old, no infection after implantable pulse generator implant, follow-up data were available ≥180 days after implant, and no explant for any reason <180 days from implant. Controls may have had an explant for reasons other than infection at >180 days after implant. Fisher exact test (for categorical variables) and Student t test (for continuous variables) were used to test the strength of the association between infection and patient and surgery characteristics. Significant variables were then considered in a multivariable logistic regression model to determine risk factors independently associated with infection. Over a 10-year period at 8 academic institutions, 1930 sacral neuromodulator implants were performed by 17 surgeons. In all, 38 cases requiring device explant for infection and 72 corresponding controls were identified. The incidence of infection requiring explant was 1.97%. Hematoma formation (13% cases, 0% controls; P = .004) and pocket depth of ≥3 cm (21% cases, 0% controls; P = .031) were independently associated with an increased risk of infection requiring explant. On multivariable regression analysis controlling for significant variables, both hematoma formation (P = .006) and pocket depth ≥3 cm (P = .020, odds ratio 3.26; 95% confidence interval, 1.20-8.89) remained significantly associated with infection requiring explant. Of the 38 cases requiring explant, 32 had cultures collected and 24 had positive cultures. All 5 cases with a hematoma had a positive culture (100%). Of the 4 cases with a pocket depth ≥3 cm, 2 had positive cultures, 1 had negative cultures, and 1 had a missing culture result. The most common organism identified was methicillin-resistant Staphylococcus aureus (38%). Infection after sacral neuromodulation requiring device explant is low. The most common infectious pathogen identified was methicillin-resistant S aureus. Demographic and health characteristics did not predict risk of explant due to infection, however, having a postoperative hematoma or a deep pocket ≥3 cm significantly increased the risk of explant due to infection. These findings highlight the importance of meticulous hemostasis as well as ensuring the pocket depth is <3 cm at the time of device implant. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Impact of crestal and subcrestal implant placement in peri-implant bone: A prospective comparative study

    PubMed Central

    Pellicer-Chover, Hilario; Peñarrocha-Diago, María; Peñarrocha-Oltra, David; Gomar-Vercher, Sonia; Agustín-Panadero, Rubén

    2016-01-01

    Background To assess the influence of the crestal or subcrestal placement of implants upon peri-implant bone loss over 12 months of follow-up. Material and Methods Twenty-six patients with a single hopeless tooth were recruited in the Oral Surgery Unit (Valencia University, Valencia, Spain). The patients were randomized into two treatment groups: group A (implants placed at crestal level) or group B (implants placed at subcrestal level). Control visits were conducted by a trained clinician at the time of implant placement and 12 months after loading. A previously established standard protocol was used to compile general data on all patients (sex and age, implant length and diameter, and brushing frequency). Implant success rate, peri-implant bone loss and the treatment of the exposed implant surface were studied. The level of statistical significance was defined as 5% (α=0.05). Results Twenty-three patients (8 males and 15 females, mean age 49.8±11.6 years, range 28-75 years) were included in the final data analyses, while three were excluded. All the included subjects were nonsmokers with a brushing frequency of up to twice a day in 85.7% of the cases. The 23 implants comprised 10 crestal implants and 13 subcrestal implants. After implant placement, the mean bone position with respect to the implant platform in group A was 0.0 mm versus 2.16±0.88 mm in group B. After 12 months of follow-up, the mean bone positions were -0.06±1.11 mm and 0.95±1.50 mm, respectively - this representing a bone loss of 0.06±1.11 mm in the case of the crestal implants and of 1.22±1.06 mm in the case of the subcrestal implants (p=0.014). Four crestal implants and 5 subcrestal implants presented peri-implant bone levels below the platform, leaving a mean exposed treated surface of 1.13 mm and 0.57 mm, respectively. The implant osseointegration success rate at 12 months was 100% in both groups. Conclusions Within the limitations of this study, bone loss was found to be greater in the case of the subcrestal implants, though from the clinical perspective these implants presented bone levels above the implant platform after 12 months of follow-up. Key words:Immediate implants, tooth extraction, dental implants, single-tooth, crestal bone, placement level. PMID:26615504

  12. Trabeculectomy with Ex-PRESS implant versus Ahmed glaucoma valve implantation-a comparative study

    PubMed Central

    Waisbourd, Michael; Fischer, Naomi; Shalev, Hadas; Spierer, Oriel; Ben Artsi, Elad; Rachmiel, Rony; Shemesh, Gabi; Kurtz, Shimon

    2016-01-01

    AIM To compare the surgical outcomes of trabeculectomy with Ex-PRESS implant and Ahmed glaucoma valve (AGV) implantation. METHODS Patients who underwent trabeculectomy with Ex-PRESS implants or AGV implantation separately were included in this retrospective chart review. Main outcome measures were surgical failure and complications. Failure was defined as intraocular pressure (IOP) >21 mm Hg or <5 mm Hg on two consecutive visits after 3mo, reoperation for glaucoma, or loss of light perception. Eyes that had not failed were considered as complete success if they did not required supplemental medical therapy. RESULTS A total of 64 eyes from 57 patients were included: 31 eyes in the Ex-PRESS group and 33 eyes in the AGV group. The mean follow-up time was 2.6±1.1y and 3.3±1.6y, respectively. Patients in the AGV group had significantly higher baseline mean IOP (P=0.005), lower baseline mean visual acuity (VA) (P=0.02), and higher proportion of patients with history of previous trabeculectomy (P<0.0001). Crude failure rates were 16.1%, n=5/31 in the Ex-PRESS group and 24.2%, n=8/33 in the AGV group. The cumulative proportion of failure was similar between the groups, P=0.696. The proportion of eyes that experienced postoperative complications was 32.3% in the Ex-PRESS group and 60.1% in the AGV group (P=0.0229). CONCLUSION Trabeculectomy with Ex-PRESS implant and AGV implantation had comparable failure rates. The AGV group had more post-operative complications, but also included more complex cases with higher baseline mean IOP, worse baseline mean VA, and more previous glaucoma surgeries. Therefore, the results are limited to the cohort included in this study. PMID:27803857

  13. In vivo evaluation of a novel nanocomposite porous 3D scaffold in a rabbit model: histological analysis

    PubMed Central

    Mahmood, Saffanah Khuder; Razak, Intan-Shameha Abdul; Ghaji, Mustafa Saddam; Yusof, Loqman Mohamed; Mahmood, Zaid Khudhur; Rameli, Mohd Adha Bin P; Zakaria, Zuki Abu Bakar

    2017-01-01

    The healing of load-bearing segmental defects in long bones is a challenge due to the complex nature of the weight that affects the bone part and due to bending, shearing, axial, and torsional forces. An innovative porous 3D scaffolds implant of CaCO3 aragonite nanocomposite derived from cockle shell was advanced for substitute bone solely for load-bearing cases. The biomechanical characteristics of such materials were designed to withstand cortical bone strength. In promoting bone growth to the implant material, an ideal surface permeability was formed by means of freeze drying and by adding copolymers to the materials. The properties of coating and copolymers supplement were also assessed for bone-implant connection resolutions. To examine the properties of the material in advanced biological system, an experimental trial in an animal model was carried out. Critical sized defect of bone was created in rabbit’s radial bone to assess the material for a load-bearing application with a short and extended period assessment with histological evaluation of the incorporated implanted material to the bone of the host. Trials in animal models proved that the material has the capability of enduring load-bearing conditions for long-term use devoid of breaking or generating stress that affects the host bone. Histological examination further confirmed the improved integration of the implanted materials to the host bone with profound bone development into and also above the implanted scaffold, which was attained with negligible reaction of the tissues to a foreign implanted material. PMID:29238193

  14. Solving intraocular lens-related pigment dispersion syndrome with repositioning of primary sulcus implanted single-piece IOL in the capsular bag.

    PubMed

    Kohnen, Thomas; Kook, Daniel

    2009-08-01

    We describe 2 cases of pigment dispersion syndrome (PDS) after uneventful phacoemulsification and implantation of a posterior chamber single-piece intraocular lens (IOL) with a sharp-edge design. In both cases, several days after IOL implantation, marked pigment dispersion was seen on the iris and in the trabecular meshwork, associated with an elevation in intraocular pressure (IOP). Thorough examination showed that the implanted IOL was in the ciliary sulcus. After surgical repositioning of both IOLs in the capsular bag, the pigment dispersion regressed and the IOP returned to normal limits. The 2 cases suggest that particularly in PDS patients, an IOL with an anterior sharp-edge design should be implanted in the capsular bag. Implantation in the ciliary sulcus should be avoided.

  15. Etonogestrel implant migration to the vasculature, chest wall, and distant body sites: cases from a pharmacovigilance database.

    PubMed

    Kang, Sarah; Niak, Ali; Gada, Neha; Brinker, Allen; Jones, S Christopher

    2017-12-01

    To describe clinical outcomes of etonogestrel implant patients with migration to the vasculature, chest wall and other distant body sites spontaneously reported to the US Food and Drug Administration Adverse Event Reporting System (FAERS) database. We performed a standardized Medical Dictionary for Regulatory Activities (MedDRA) query in the FAERS database (through November 15, 2015), with reports coded with one or more MedDRA preferred terms that indicate complications with device placement or migration of the device from the original site of insertion to the vasculature, chest wall and other distant body sites. We excluded any cases previously described in the medical literature. We identified 38 cases of pronounced etonogestrel implant migration. Migration locations included the lung/pulmonary artery (n=9), chest wall (n=1), vasculature at locations other than the lung/pulmonary artery (n=14) and extravascular migrations (n=14) to other body sites (e.g., the axilla and clavicle/neck line/shoulder). The majority of cases were asymptomatic and detected when the patient desired implant removal; however, seven cases reported symptoms such as pain, discomfort and dyspnea in association with implant migration. Three cases also describe pulmonary fibrosis and skin reactions as a result of implant migration to the vasculature, chest wall and other distant body sites. Sixteen cases reported surgical removal in an operating room setting. Our FAERS case series demonstrates etonogestrel implant migration to the vasculature, chest wall and other body sites distant from the site of original insertion. As noted by the sponsor in current prescribing information, a key determinant in the risk for etonogestrel contraceptive implant migration appears to be improper insertion technique. Although migration of etonogestrel implants to the vasculature is rare, awareness of migration and education on proper insertion technique may reduce the risk. Published by Elsevier Inc.

  16. [Treatment of enophthalmos after severe malar-maxillary complex fracture with titanium mesh and high density polyethylene (Medpor)].

    PubMed

    Zhao, Yan-feng; Lu, Ping; Zhou, Xiao-nan; Qu, Chang-feng

    2010-03-01

    To study the surgical management of enophthalmos after severe malar maxillary complex fracture. The X-ray and CT examination were performed before operation to diagnose the orbital fracture and intraorbital tissue displacement. The fractured orbital rim was repositioned intraoperatively, followed by implantation of shaped titanium mesh to rebuild the orbital floor. The Medpor was inserted above the titanium mesh to correct the enophthalmos. From Sept. 2007 to Jan. 2009, 6 cases of enophthalmos after severe malar-maxillary complex fracture were treated. The enophthalmos was corrected or improved obviously in all the patients. The enophthalmos after severe malar-maxillary complex fracture can be corrected or obviously improved. Shaped titanium mesh can be used to rebuild the orbital floor with the Medpor to reconstruct the intraorbital tissue volume.

  17. Sapphire implant based neuro-complex for deep-lying brain tumors phototheranostics

    NASA Astrophysics Data System (ADS)

    Sharova, A. S.; Maklygina, YU S.; Yusubalieva, G. M.; Shikunova, I. A.; Kurlov, V. N.; Loschenov, V. B.

    2018-01-01

    The neuro-complex as a combination of sapphire implant optical port and osteoplastic biomaterial "Collapan" as an Aluminum phthalocyanine nanoform photosensitizer (PS) depot was developed within the framework of this study. The main goals of such neuro-complex are to provide direct access of laser radiation to the brain tissue depth and to transfer PS directly to the pathological tissue location that will allow multiple optical phototheranostics of the deep-lying tumor region without repeated surgical intervention. The developed complex spectral-optical properties research was carried out by photodiagnostics method using the model sample: a brain tissue phantom. The optical transparency of sapphire implant allows obtaining a fluorescent signal with high accuracy, comparable to direct measurement "in contact" with the tissue.

  18. Three-Dimensional Implant Positioning with a Piezosurgery Implant Site Preparation Technique and an Intraoral Surgical Navigation System: Case Report.

    PubMed

    Pellegrino, Gerardo; Taraschi, Valerio; Vercellotti, Tomaso; Ben-Nissan, Besim; Marchetti, Claudio

    This case report describes new implant site preparation techniques joining the benefits of using an intraoral navigation system to optimize three-dimensional implant site positioning in combination with an ultrasonic osteotomy. A report of five patients is presented, and the implant positions as planned in the navigation software with the postoperative scan image were compared. The preliminary results are useful, although further clinical studies with larger populations are needed to confirm these findings.

  19. Anaplastic large cell lymphoma (ALCL) and breast implants: breaking down the evidence.

    PubMed

    Ye, Xuan; Shokrollahi, Kayvan; Rozen, Warren M; Conyers, Rachel; Wright, Penny; Kenner, Lukas; Turner, Suzanne D; Whitaker, Iain S

    2014-01-01

    Systemic anaplastic large cell lymphoma (ALCL) is a distinct disease classification provisionally sub-divided into ALCL, Anaplastic Lymphoma Kinase (ALK)(+) and ALCL, ALK(-) entities. More recently, another category of ALCL has been increasingly reported in the literature and is associated with the presence of breast implants. A comprehensive review of the 71 reported cases of breast implant associated ALCL (iALCL) is presented indicating the apparent risk factors and main characteristics of this rare cancer. The average patient is 50 years of age and most cases present in the capsule surrounding the implant as part of the periprosthetic fluid or the capsule itself on average at 10 years post-surgery suggesting that iALCL is a late complication. The absolute risk is low ranging from 1:500,000 to 1:3,000,000 patients with breast implants per year. The majority of cases are ALK-negative, yet are associated with silicone-coated implants suggestive of the mechanism of tumorigenesis which is discussed in relation to chronic inflammation, immunogenicity of the implants and sub-clinical infection. In particular, capsulotomy alone seems to be sufficient for the treatment of many cases suggesting the implants provide the biological stimulus whereas others require further treatment including chemo- and radiotherapy although reported cases remain too low to recommend a therapeutic approach. However, CD30-based therapeutics might be a future option. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Intraosseous venous malformation of the zygomatico-orbital complex. Case report and literature review with focus on confusions in vascular lesion terms.

    PubMed

    Fábián, Zoltán; Szabó, György; Petrovan, Cecilia; Horváth, Karin Ursula; Babicsák, Botond; Hüttl, Kálmán; Németh, Zsolt; Bogdán, Sándor

    2018-06-01

    Intraosseous vascular malformations (VascM) of the facial skeleton are rare entities, raising difficulties even today in their treatment. We present a case for zygomatic intraosseous venous malformation of traumatic etiology with growth dynamics presentation and a multidisciplinary treatment approach, with intravascular embolization surgical ablation and primary reconstructruction using a titanium patient-specific implant (PSI), and a review of the literature for intraosseous vascular lesions of the facial skeleton focusing on the diagnostic syntagms used by the involved medical personnel, to shed light on the confusions over these terms.

  1. A new custom made bioceramic implant for the repair of large and complex craniofacial bone defects.

    PubMed

    Brie, Joël; Chartier, Thierry; Chaput, Christophe; Delage, Cyrille; Pradeau, Benjamin; Caire, François; Boncoeur, Marie-Paule; Moreau, Jean-Jacques

    2013-07-01

    Neurosurgery and Maxillofacial Surgery Departments of Limoges University Hospital Centre have developed a new concept of a custom made ceramic implant in hydroxyapatite (HA) for the reconstruction of large and complex craniofacial bone defects (more than 25 cm(2)). The manufacturing process of the implants used a stereolithography technique that produces implants with three-dimensional shapes derived directly from the scan file of the patient's skull without moulding or machining. Eight patients received 8 implants between 2005 and 2008. The surgical procedure is simple and fast. The post-operative follow-up was 12 months. No major complications (infection or fracture of the implant) were observed. The cosmetic result was considered satisfactory by both patients and surgeons. These new implants are well suited for reconstruction of large craniofacial bone defects (greater than 25 cm(2)) in adults and children over 8 years. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Sirviendo a los estudiantes sordos que tienen Los implantes cocleares. Hoja de consejos de PEPNet (Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet)

    ERIC Educational Resources Information Center

    Clark, Catherine

    2010-01-01

    This version of "Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet," written in Spanish, describes how cochlear implants (CIs) work. CIs are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of…

  3. Hypnosis as a Valuable Tool for Surgical Procedures in the Oral and Maxillofacial Area.

    PubMed

    Montenegro, Gil; Alves, Luiza; Zaninotto, Ana Luiza; Falcão, Denise Pinheiro; de Amorim, Rivadávio Fernandes Batista

    2017-04-01

    Hypnosis is a valuable tool in the management of patients who undergo surgical procedures in the maxillofacial complex, particularly in reducing and eliminating pain during surgery and aiding patients who have dental fear and are allergic to anesthesia. This case report demonstrates the efficacy of hypnosis in mitigating anxiety, bleeding, and pain during dental surgery without anesthesia during implant placement of tooth 14, the upper left first molar.

  4. Four years survival and marginal bone loss of implants in patients with Down syndrome and cerebral palsy.

    PubMed

    Corcuera-Flores, José Ramón; López-Giménez, Julián; López-Jiménez, Julián; López-Giménez, Ana; Silvestre-Rangil, Javier; Machuca-Portillo, Guillermo

    2017-06-01

    To evaluate implant survival rate and marginal bone loss (MBL) after 4 years in patients with Down syndrome and cerebral palsy, compared with a healthy control group. The case group comprises 102 implants in 19 patients (71 cerebral palsy, 21 Down syndrome), and the control group comprises 70 implants in 22 healthy patients. One implant per patient was selected (n = 41 implants) to take clustering effects into account. MBL was measured using two panoramic radiographs (after surgery and 4 years later). Lagervall-Jansson's Index was used. Statistics used are chi-squared test and Haberman's post hoc test. p Value is significant at <0.05. MBL was significantly higher in the cases in all samples (p < 0.001) and when one implant was selected per patient (p < 0.05). More implants were lost in the cases (p < 0.01), especially those with a higher MBL (p < 0.01). MBL (p < 0.05) and implant loss (p < 0.01) increased with age in the cases. The three-unit fixed dental prosthesis (FDP) showed higher MBL (p < 0.05). Down syndrome had a higher MBL than cerebral palsy (entire sample p < 0.0001, one implant per patient p < 0.05). All patients with Down syndrome saw some damage to bone support (entire sample p < 0.0001; one implant per patient p < 0.05). Implant loss occurred only in Down syndrome (p < 0.00001). MBL and implant loss 4 years after placement are higher in neuropsychiatric disabilities. Down syndrome has a higher risk of MBL and implant loss; therefore, special precautions should be taken when deciding on treatment for these patients. As a consequence of this pilot study, professionals should be very cautious in placing implants in patients with Down syndrome.

  5. Surgical management of fractured orthodontic mini- implant- a case report.

    PubMed

    Desai, Manthan; Jain, Anoop; Sumra, Nida

    2015-01-01

    The idea of absolute anchorage has always been an elusive goal for clinicians. Orthodontic mini-implants or temporary anchorage devices allow tooth movements previously thought to be impossible or difficult. Although extensive literature exists on use of temporary anchorage devices, their failures have been hardly focused upon, especially implant fracture. The following case report describes successful management of fractured orthodontic mini-implant.

  6. Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet

    ERIC Educational Resources Information Center

    Searls, J. Matt, Comp.

    2010-01-01

    Cochlear implants (CIs) are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of individuals with significant permanent hearing loss. Cochlear implants may not be suitable for everyone. They are designed to provide…

  7. Multiblock High Order Large Eddy Simulation of Powered Fontan Hemodynamics: Towards Computational Surgery

    PubMed Central

    Delorme, Yann T.; Rodefeld, Mark D.; Frankel, Steven H.

    2016-01-01

    Children born with only one functional ventricle must typically undergo a series of three surgeries to obtain the so-called Fontan circulation in which the blood coming from the body passively flows from the Vena Cavae (VCs) to the Pulmonary Arteries (PAs) through the Total Cavopulmonary Connection (TCPC). The circulation is inherently inefficient due to the lack of a subpulmonary ventricle. Survivors face the risk of circulatory sequelae and eventual failure for the duration of their lives. Current efforts are focused on improving the outcomes of Fontan palliation, either passively by optimizing the TCPC, or actively by using mechanical support. We are working on a chronic implant that would be placed at the junction of the TCPC, and would provide the necessary pressure augmentation to re-establish a circulation that recapitulates a normal two-ventricle circulation. This implant is based on the Von Karman viscous pump and consists of a vaned impeller that rotates inside the TCPC. To evaluate the performance of such a device, and to study the flow features induced by the presence of the pump, Computational Fluid Dynamics (CFD) is used. CFD has become an important tool to understand hemodynamics owing to the possibility of simulating quickly a large number of designs and flow conditions without any harm for patients. The transitional and unsteady nature of the flow can make accurate simulations challenging. We developed and in-house high order Large Eddy Simulation (LES) solver coupled to a recent Immersed Boundary Method (IBM) to handle complex geometries. Multiblock capability is added to the solver to allow for efficient simulations of complex patient specific geometries. Blood simulations are performed in a complex patient specific TCPC geometry. In this study, simulations without mechanical assist are performed, as well as after virtual implantation of the temporary and chronic implants being developed. Instantaneous flow structures, hepatic factor distribution, and statistical data are presented for all three cases. PMID:28649147

  8. A new spiral dental implant: a tool for oral rehabilitation of difficult cases

    PubMed Central

    BALAN, I.; CALCATERRA, R.; LAURITANO, D.; GRECCHI, E.; CARINCI, F.

    2017-01-01

    SUMMARY Spiral dental implant (SDI) is an implant with a conical internal helix that confers the characteristic of self-drilling, self-tapping, and self-bone condensing. These proprieties offer better control during insertion of SDI giving a high primary stabilization, even in poor quality bone. A shorter diameter of SDI results in reduced drilling during insertion and consequently less trauma and minimal bone loss. To address the research purpose, the investigators designed a retrospective cohort study. The study population was composed of 25 patients, 11 males and 14 females that have been treated by Dr. Balan with 187 SDI positioned in mandible and into maxilla bone. The implants were placed during the years 2013 to 2014 in Dr. Balan clinic. All patients underwent the same surgical protocol. Several variables are investigated: demographic (age and gender), anatomic (upper/lower jaws and tooth site), implant (length and diameter and type) variables, edentulism (partial or total), and comorbid status of health (i.e.: hypothyroidism, parodontitis, hypertension, diabetes, presence of cancer, heart disease, hepatitis and rheumatologic disease). Pearson Chi-Square test was used to investigate variables and p < 0.05 was considered statistically significant. Statistically it has been shown that females have a higher possibility of unsuccessful respect of male, with a “p value” of 0.014. Another important impact factor for success of implant insertion has been represented by concomitants pathologies: cancer represents the most negative high factor risk with a percentage of unsuccessful of 50%, followed by heart disease (15%), and diabetes (3.7%). SDIs are reliable tools for difficult cases of oral rehabilitation. They have a higher success and survival rate, which means stable results over time. No differences were detected among SDI lengths, implant/crown ratio. In addition, the insertion of SDIs in banked bone can be performed without adverse effects. Finally, flapless and computer tomography-planned surgery does not significantly increase the clinical outcome of SDIs in complex rehabilitation. Cancer represents the most important variable to consider when a patient wants to do oral rehabilitation because of its high risk of unsuccessful. PMID:29285328

  9. A new spiral dental implant: a tool for oral rehabilitation of difficult cases.

    PubMed

    Balan, I; Calcaterra, R; Lauritano, D; Grecchi, E; Carinci, F

    2017-01-01

    Spiral dental implant (SDI) is an implant with a conical internal helix that confers the characteristic of self-drilling, self-tapping, and self-bone condensing. These proprieties offer better control during insertion of SDI giving a high primary stabilization, even in poor quality bone. A shorter diameter of SDI results in reduced drilling during insertion and consequently less trauma and minimal bone loss. To address the research purpose, the investigators designed a retrospective cohort study. The study population was composed of 25 patients, 11 males and 14 females that have been treated by Dr. Balan with 187 SDI positioned in mandible and into maxilla bone. The implants were placed during the years 2013 to 2014 in Dr. Balan clinic. All patients underwent the same surgical protocol. Several variables are investigated: demographic (age and gender), anatomic (upper/lower jaws and tooth site), implant (length and diameter and type) variables, edentulism (partial or total), and comorbid status of health (i.e.: hypothyroidism, parodontitis, hypertension, diabetes, presence of cancer, heart disease, hepatitis and rheumatologic disease). Pearson Chi-Square test was used to investigate variables and p < 0.05 was considered statistically significant. Statistically it has been shown that females have a higher possibility of unsuccessful respect of male, with a "p value" of 0.014. Another important impact factor for success of implant insertion has been represented by concomitants pathologies: cancer represents the most negative high factor risk with a percentage of unsuccessful of 50%, followed by heart disease (15%), and diabetes (3.7%). SDIs are reliable tools for difficult cases of oral rehabilitation. They have a higher success and survival rate, which means stable results over time. No differences were detected among SDI lengths, implant/crown ratio. In addition, the insertion of SDIs in banked bone can be performed without adverse effects. Finally, flapless and computer tomography-planned surgery does not significantly increase the clinical outcome of SDIs in complex rehabilitation. Cancer represents the most important variable to consider when a patient wants to do oral rehabilitation because of its high risk of unsuccessful.

  10. Three-Dimensional Nonlinear Finite Element Analysis and Microcomputed Tomography Evaluation of Microgap Formation in a Dental Implant Under Oblique Loading.

    PubMed

    Jörn, Daniela; Kohorst, Philipp; Besdo, Silke; Borchers, Lothar; Stiesch, Meike

    2016-01-01

    Since bacterial leakage along the implant-abutment interface may be responsible for peri-implant infections, a realistic estimation of the interface gap width during function is important for risk assessment. The purpose of this study was to compare two methods for investigating microgap formation in a loaded dental implant, namely, microcomputed tomography (micro-CT) and three-dimensional (3D) nonlinear finite element analysis (FEA); additionally, stresses to be expected during loading were also evaluated by FEA. An implant-abutment complex was inspected for microgaps between the abutment and implant in a micro-CT scanner under an oblique load of 200 N. A numerical model of the situation was constructed; boundary conditions and external load were defined according to the experiment. The model was refined stepwise until its load-displacement behavior corresponded sufficiently to data from previous load experiments. FEA of the final, validated model was used to determine microgap widths. These were compared with the widths as measured in micro-CT inspection. Finally, stress distributions were evaluated in selected regions. No microgaps wider than 13 μm could be detected by micro-CT for the loaded implant. FEA revealed gap widths up to 10 μm between the implant and abutment at the side of load application. Furthermore, FEA predicted plastic deformation in a limited area at the implant collar. FEA proved to be an adequate method for studying microgap formation in dental implant-abutment complexes. FEA is not limited in gap width resolution as are radiologic techniques and can also provide insight into stress distributions within the loaded complex.

  11. Maintenance of class III trifurcated molars versus implant placement in regenerated extraction sockets: long-term results of 2 cases.

    PubMed

    Zafiropoulos, Gregory-George K; di Prisco, Manuela Occipite; Deli, Giorgio; Hoffmann, Oliver

    2011-03-01

    Studies to date have reached differing conclusions regarding the long-term prognosis of teeth with class III furcation involvement. Replacement of such teeth with implants could be an alternative. This report compares the treatment outcomes of 2 cases with similar disease progression: 1 treated by implant therapy and 1 maintained with nonsurgical periodontal treatment. Two patients with advanced chronic periodontitis and class III furcation involvement of all molars were treated. Case 1 received a conservative periodontal and antibiotic treatment, followed by 15 years of maintenance. In case 2, the molars were extracted and replaced with implants, and the implants were observed for 7 years. Clinical attachment level (CAL), probing attachment level (PAL), bleeding on probing, plaque index, and periodontal pathogens were recorded. Despite good compliance of case 1, periodontal pathogens were not eliminated and tissue destruction was not halted. The PAL outcomes of case 2 improved over time; mean PAL loss reached 0.35 mm/y in the first 3 years and then decreased to 0.01 mm/y. While CAL outcomes did not change in case 2, case 1 showed increased CAL loss after 8 years. Based on the limited findings of this case report, extraction of molars with class III furcation involvement and subsequent implant placement may render a better predictability of treatment outcomes than nonsurgical periodontal therapy in the cases of infection with periodontal pathogens.

  12. Complications and results of subdural grid electrode implantation in epilepsy surgery.

    PubMed

    Lee, W S; Lee, J K; Lee, S A; Kang, J K; Ko, T S

    2000-11-01

    We assessed the risk of delayed subdural hematoma and other complications associated with subdural grid implantation. Forty-nine patients underwent subdural grid implantation with/without subdural strips or depth electrodes from January 1994 to August 1998. To identify the risk associated with subdural grid implantation, a retrospective review of all patients' medical records and radiological studies was performed. The major complications of 50 subdural grid electrode implantations were as follows: four cases (7.8%) of delayed subdural hematoma at the site of the subdural grid, requiring emergency operation; two cases (3.9%) of infection; one case (2.0%) of epidural hematoma; and one case (2.0%) of brain swelling. After subdural hematoma removal, the electrodes were left in place. CCTV monitoring and cortical stimulation studies were continued thereafter. No delayed subdural hematoma has occurred since routine placement of subdural drains was begun. In our experience the worst complication of subdural grid implantation has been delayed subdural hematoma. Placement of subdural drains and close observation may be helpful to prevent this serious complication.

  13. [Cochlear implantation in patients with Waardenburg syndrome type II].

    PubMed

    Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian

    2010-05-01

    To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.

  14. A case of brugada syndrome presenting with ventricular fibrillation storm and prominent early repolarization.

    PubMed

    Iizuka, Chifumi; Sato, Masahito; Kitazawa, Hitoshi; Ikeda, Yoshio; Okabe, Masaaki; Kugiyama, Kiyotaka; Aizawa, Yoshifusa

    2016-01-01

    A 21-year-old man developed ventricular fibrillation (VF) while drinking alcohol and was admitted to our hospital. An electrocardiogram (ECG) on admission revealed remarkably prominent slurs on the terminal part of QRS complexes in the left precordial leads and a coved type ST elevation at higher intercostal spaces. After hypothermia therapy, he underwent implantation of an implantable cardioverter-defibrillator (ICD). Standard twelve-lead follow-up ECGs revealed early repolarization pattern and an intermittent coved type ST elevation. When the coved type ST elevation appeared, the early repolarization pattern in the inferior and left precordial leads was attenuated. Prominent early repolarization pattern was the most likely trigger of the VF storm in this Brugada patient. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Immediate loading of titanium hexed screw-type implants in the edentulous patient: case report.

    PubMed

    Calvo, M P; Muller, E; Garg, A K

    2000-01-01

    Histologic and histomorphometric studies in both animals and humans have shown that more rapid and greater bone-to-implant contact can be achieved with implants that incorporate certain surface characteristics compared with the original machined-surface implants. Such findings are significant because various implant designs may allow the fixtures to sufficiently resist functional loading sooner than originally thought. The case report presented here indicates that immediate loading of hexed titanium screw-type implants in the anterior mandible can lead to successful osseointegration and clinical outcome. The number of implants placed, their distribution, and the type of rigid connection are critical considerations for immediate loading. A bone height that can accommodate dental implants > or = 10 mm long is recommended. Biomechanically, the implants to be immediately loaded must be stable and resistant to macromovement to ensure good osseointegration.

  16. [Correction of aphakia with the implantation of the retropupillary iris clip intraocular artificial lens].

    PubMed

    Szabó, Antal; Papp, András; Borbándy, Ágnes; D Géhl, Zsuzsanna; Nagy, Zoltán Zsolt; Resch, Miklós

    2017-01-01

    The correction of aphakia might be a challenge for the surgeon. The aim of this study is to describe the authors' experience with the implantation of the retropupillary iris clip intraocular lens. Patients between January 2014 and December 2015 were included in the retrospective study. Retropupillary implantation of iris clip intraocular lens VRSA 54 (AMO Advanced Medical Optics, USA) was performed in all cases. The minimum follow up period was three months. The stability of the intraocular lens and the intraoperative and postoperative complications and the visual acuity were evaluated. During this time period 11 cases (1 female, 10 males) were included in the study. The mean age at the time of the implantation was 57.7 years (between 25-74 years). In 4 cases the iris clip lens was implanted during the first intervention, in 7 cases during the secondary procedure. In all cases the lens was fixated onto the iris posteriorly. The best corrected visual acuity before the iris clip implantation was 0.43 (0.1-1.0) and postoperatively at the time of the follow up 0.49 (0.04-1.0). With the use of the retropupillary implanted iris clip intraocular lens all of the patients could have been rehabilitated without major complications. Orv. Hetil., 2017, 158(1), 20-24.

  17. Treatment of Severely Resorbed Maxilla Due to Peri-Implantitis by Guided Bone Regeneration Using a Customized Allogenic Bone Block: A Case Report

    PubMed Central

    Blume, Oliver; Hoffmann, Lisa; Donkiewicz, Phil; Wenisch, Sabine; Back, Michael; Franke, Jörg; Schnettler, Reinhard

    2017-01-01

    The objective of this case report is to introduce a customized CAD/CAM freeze-dried bone allograft (FDBA) block for its use in Guided Bone Regeneration (GBR) procedures for severely deficient maxillary bones. Additionally, a special newly developed remote incision technique is presented to avoid wound dehiscence. The results show optimal integration behavior of the FDBA block after six months and the formation of new vital bone. Thus, the results of the present case report confirm the use of the customized CAD/CAM bone block for augmentation of complex defects in the maxillary aesthetic zone as a successful treatment concept. PMID:29065477

  18. Treatment of Severely Resorbed Maxilla Due to Peri-Implantitis by Guided Bone Regeneration Using a Customized Allogenic Bone Block: A Case Report.

    PubMed

    Blume, Oliver; Hoffmann, Lisa; Donkiewicz, Phil; Wenisch, Sabine; Back, Michael; Franke, Jörg; Schnettler, Reinhard; Barbeck, Mike

    2017-10-21

    The objective of this case report is to introduce a customized CAD/CAM freeze-dried bone allograft (FDBA) block for its use in Guided Bone Regeneration (GBR) procedures for severely deficient maxillary bones. Additionally, a special newly developed remote incision technique is presented to avoid wound dehiscence. The results show optimal integration behavior of the FDBA block after six months and the formation of new vital bone. Thus, the results of the present case report confirm the use of the customized CAD/CAM bone block for augmentation of complex defects in the maxillary aesthetic zone as a successful treatment concept.

  19. Biomechanics and strain mapping in bone as related to immediately-loaded dental implants

    PubMed Central

    Du, Jing; Lee, Jihyun; Jang, Andrew; Gu, Allen; Hossaini-Zadeh, Mehran; Prevost, Richard; Curtis, Don; Ho, Sunita

    2015-01-01

    The effects of alveolar bone socket geometry and bone-implant contact on implant biomechanics, and resulting strain distributions in bone were investigated. Following extraction of lateral incisors on a cadaver mandible, immediate implants were placed and bone-implant contact area, stability and bone strain were measured. In situ biomechanical testing coupled with micro X-ray microscope (μ-XRM) illustrated less stiff bone-implant complexes (701-822 N/mm) compared with bone-periodontal ligament (PDL)-tooth complexes (791-913 N/mm). X-ray tomograms illustrated that the cause of reduced stiffness was due to reduced and limited bone-implant contact. Heterogeneous elemental composition of bone was identified by using energy dispersive X-ray spectroscopy (EDS). The novel aspect of this study was the application of a new experimental mechanics method, that is, digital volume correlation, which allowed mapping of strains in volumes of alveolar bone in contact with a loaded implant. The identified surface and subsurface strain concentrations were a manifestation of load transferred to bone through bone-implant contact based on bone-implant geometry, quality of bone, implant placement, and implant design. 3D strain mapping indicated that strain concentrations are not exclusive to the bone-implant contact regions, but also extend into bone not directly in contact with the implant. The implications of the observed strain concentrations are discussed in the context of mechanobiology. Although a plausible explanation of surgical complications for immediate implant treatment is provided, extrapolation of results is only warranted by future systematic studies on more cadaver specimens and/or in vivo small scale animal models. PMID:26162549

  20. Ultrasonic implant site preparation using piezosurgery: a multicenter case series study analyzing 3,579 implants with a 1- to 3-year follow-up.

    PubMed

    Vercellotti, Tomaso; Stacchi, Claudio; Russo, Crescenzo; Rebaudi, Alberto; Vincenzi, Giampaolo; Pratella, Umberto; Baldi, Domenico; Mozzati, Marco; Monagheddu, Chiara; Sentineri, Rosario; Cuneo, Tommaso; Di Alberti, Luca; Carossa, Stefano; Schierano, Gianmario

    2014-01-01

    This multicenter case series introduces an innovative ultrasonic implant site preparation (UISP) technique as an alternative to the use of traditional rotary instruments. A total of 3,579 implants were inserted in 1,885 subjects, and the sites were prepared using a specific ultrasonic device with a 1- to 3-year follow-up. No surgical complications related to the UISP protocol were reported for any of the implant sites. Seventy-eight implants (59 maxillary, 19 mandibular) failed within 5 months of insertion, for an overall osseointegration percentage of 97.82% (97.14% maxilla, 98.75% mandible). Three maxillary implants failed after 3 years of loading, with an overall implant survival rate of 97.74% (96.99% maxilla, 98.75% mandible).

  1. R&D on dental implants breakage

    NASA Astrophysics Data System (ADS)

    Croitoru, Sorin Mihai; Popovici, Ion Alexandru

    2017-09-01

    Most used dental implants for human dental prostheses are of two steps type: first step means implantation and, after several months healing and osseointegration, second step is prosthesis fixture. For sure, dental implants and prostheses are meant to last for a lifetime. Still, there are unfortunate cases when dental implants break. This paper studies two steps dental implants breakage and proposes a set of instruments for replacement and restoration of the broken implant. First part of the paper sets the input data of the study: structure of the studied two steps dental implants based on two Romanian patents and values of the loading forces found in practice and specialty papers. In the second part of the paper, using DEFORM 2D™ FEM simulation software, worst case scenarios of loading dental implants are studied in order to determine which zones and components of the dental implant set are affected (broken). Last part of the paper is dedicated to design and presentation of a set for extracting and cutting tools used to restore the broken implant set.

  2. [Clinical use of beta-tricalcium phosphate ceramics with patient's own bone in maxillary elevation with osteotome].

    PubMed

    Chen, Lu; Zhou, Wen-qing; Wu, Yan-ping; Lu, Jing-hua

    2011-06-01

    To evaluate the clinical value of using the patient's autogenous bone mixed with beta-tricalcium phosphate ceramics(β-TCP) for maxillary sinus lift with simultaneous implantation. Patients with loss of posterior teeth and bone height of maxillary sinus floor between 4-10mm underwent internal sinus floor elevation, the proportion of bone to β-TCP was 1:1 and the mixture was inserted into the sinus floor. All cases had simultaneously placed ITI implants.The final crown fabrication was taken 4-6 months after implanting. Twenty-one implants were inserted in 16 cases, the mean increase height was 4.2mm(2-6mm). There was clinical complaint of maxillary sinus inflammation in 1 case within 2 weeks, but the symptoms disappeared after antibiotic therapy. The remaining of 20 implants had no obvious complications. All implants had loaded for 32 months and were stable and well osseointegration on X-ray film. Maxillary sinus elevation with simultaneous implantation is an easy procedure. Implants can be stable for a long time.

  3. Breast fibromatosis associated with breast implants.

    PubMed

    Seo, Yoon Nae; Park, Young Mi; Yoon, Hye Kyoung; Lee, Sun Joo; Choo, Hye Jung; Ryu, Ji Hwa

    2015-09-01

    Fibromatosis refers to an extra-abdominal desmoid tumor or aggressive fibromatosis. Breast fibromatosis can develop in association with the capsule around a breast implant, although reports of cases of fibromatosis associated with breast implants are rare. As the demand for breast augmentation has increased, it is important to understand the diseases associated with breast implants. In the present report, we describe a case of breast fibromatosis that developed adjacent to a breast implant and demonstrated a relatively well-defined border even though it invaded the surrounding structures. We also explore the specific imaging features for diagnosing breast fibromatosis in association with implants by reviewing previous literature.

  4. Challenges to validation of a complex nonsterile medical device tray.

    PubMed

    Prince, Daniel; Mastej, Jozef; Hoverman, Isabel; Chatterjee, Raja; Easton, Diana; Behzad, Daniela

    2014-01-01

    Validation by steam sterilization of reusable medical devices requires careful attention to many parameters that directly influence whether or not complete sterilization occurs. Complex implant/instrument tray systems have a variety of configurations and components. Geobacillus stearothermophilus biological indicators (BIs) are used in overkill cycles to to simulate worst case conditions and are intended to provide substantial sterilization assurance. Survival of G. stearothermophilus spores was linked to steam access and size of load in the chamber. By a small and reproducible margin, it was determined that placement of the trays in a rigid container into minimally loaded chambers were more difficult to completely sterilize than maximally loaded chambers.

  5. Color Analysis of Periimplant Soft Tissues Focusing on Implant System: A Case Series.

    PubMed

    Varoni, Elena M; Moltrasio, Giuseppe; Gargano, Marco; Ludwig, Nicola; Lodi, Giovanni; Scaringi, Riccardo

    2017-04-01

    To assess the impact of implant system on color harmonization of periimplant mucosa. In this case series, color of periimplant mucosa was compared with color of natural tooth gingiva. Seventeen intercanine implants were analyzed (11 bone level [BL], 6 tissue level [TL] implants). Colorimetric data, at 2, 4, and 6 mm from gingival margin, were collected through fiber optics reflectance spectroscopy, and color differences calculated as ΔE. Dentists, dental students, and lay people, in blind, performed an additional visual color analysis on clinical images. Independently from implant system, the color of periimplant mucosa was significantly different from gingiva (ΔE = 8.2 ± 0.7), resulting darker at L* comparison (P ≤ 0.05). TL periimplant mucosa showed higher ΔE than BL (9.0 ± 1.0 vs 6.6 ± 0.8, respectively; P ≤ 0.05). Observers correctly identified where the implant was placed in about half of the cases, with no significant difference between implant systems. Within the limitations of this study, the color of periimplant soft tissues appears different from gingiva, at spectroscopic analysis. Color discrepancy results higher in the presence of TL implants than in BL implants, although the difference may not be clinically significant.

  6. Complex pattern of colon cancer recurrence including a kidney metastasis: A case report

    PubMed Central

    Waleczek, Helfried; Wente, Moritz N; Kozianka, Jürgen

    2005-01-01

    We report a case of a 77-year-old female with a local recurrence of cancer after right hemicolectomy which infiltrated the pancreatic head affording pancrea-toduodenectomy, who developed 3 years later recurrent tumor masses localized in the mesentery of the jejunum and in the lower pole of the left kidney. Partial nephrectomy and a segment resection of the small bowel were performed. Histological examination of both specimens revealed a necrotic metastasis of the primary carcinoma of the colon. Although intraluminal implantation of colon cancer cells in the renal pelvic mucosa from ureteric metastasis has been described, metastasis of a colorectal cancer in the kidney parenchyma is extremely rare and can be treated in an organ preserving manner. A complex pattern of colon cancer recurrence with unusual and rare sites of metastasis is reported. PMID:16222759

  7. [Navigated implantation of total knee endoprostheses--a comparative study with conventional instrumentation].

    PubMed

    Jenny, J Y; Boeri, C

    2001-01-01

    A navigation system should improve the quality of a total knee prosthesis implantation in comparison to the classical, surgeon-controlled operative technique. The authors have implanted 40 knee total prostheses with an optical infrared navigation system (Orthopilot AESCULAP, Tuttlingen--group A). The quality of implantation was studied on postoperative long leg AP and lateral X-rays, and compared to a control group of 40 computer-paired total knee prostheses o the same model (Search Prosthesis, AESCULAP, Tuttlingen) implanted with a classical, surgeon-controlled technique (group B). An optimal mechanical femorotibial angle (3 degrees valgus to 3 degrees varus) was obtained by 33 cases in group A and 31 cases in group B (p > 0.05). Better results were seen for the coronal and sagittal orientation of both tibial and femoral components in group A. Globally, 26 cases of the group A and 12 cases of the group B were implanted in an optimal manner for all studied criteria (p < 0.01). The used navigation system allows a significant improvement of the quality of implantation of a knee total prosthesis in comparison to a classical, surgeon-controlled instrumentation. Long-term outcome could be consequently improved.

  8. Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases.

    PubMed

    Ricciardi, Benjamin F; Nocon, Allina A; Jerabek, Seth A; Wilner, Gabrielle; Kaplowitz, Elianna; Goldring, Steven R; Purdue, P Edward; Perino, Giorgio

    2016-01-01

    Adverse local tissue reaction (ALTR), characterized by a heterogeneous cellular inflammatory infiltrate and the presence of corrosion products in the periprosthetic soft tissues, has been recognized as a mechanism of failure in total hip replacement (THA). Different histological subtypes may have unique needs for longitudinal clinical follow-up and complication rates after revision arthroplasty. The purpose of this study was to describe the histological patterns observed in the periprosthetic tissue of failed THA in three different implant classes due to ALTR and their association with clinical features of implant failure. Consecutive patients presenting with ALTR from three major hip implant classes (N = 285 cases) were identified from our prospective Osteolysis Tissue Database and Repository. Clinical characteristics including age, sex, BMI, length of implantation, and serum metal ion levels were recorded. Retrieved synovial tissue morphology was graded using light microscopy. Clinical characteristics and features of synovial tissue analysis were compared between the three implant classes. Histological patterns of ALTR identified from our observations and the literature were used to classify each case. The association between implant class and histological patterns was compared. Our histological analysis demonstrates that ALTR encompasses three main histological patterns: 1) macrophage predominant, 2) mixed lymphocytic and macrophagic with or without features of associated with hypersensitivity/allergy or response to particle toxicity (eosinophils/mast cells and/or lymphocytic germinal centers), and 3) predominant sarcoid-like granulomas. Implant classification was associated with histological pattern of failure, and the macrophagic predominant pattern was more common in implants with metal-on-metal bearing surfaces (MoM HRA and MoM LHTHA groups). Duration of implantation and composition of periprosthetic cellular infiltrates was significantly different amongst the three implant types examined suggesting that histopathological features of ALTR may explain the variability of clinical implant performance in these cases. ALTR encompasses a diverse range of histological patterns, which are reflective of both the implant configuration independent of manufacturer and clinical features such as duration of implantation. The macrophagic predominant pattern and its mechanism of implant failure represent an important subgroup of ALTR which could become more prominent with increased length of implantation.

  9. The right not to hear: the ethics of parental refusal of hearing rehabilitation.

    PubMed

    Byrd, Serena; Shuman, Andrew G; Kileny, Sharon; Kileny, Paul R

    2011-08-01

    To explore the ethics of parental refusal of auditory-oral hearing rehabilitation. Case study with medical ethical discussion and review. Two young brothers present with severe-to-profound congenital sensorineural hearing loss. The parents, both of whom have normal hearing and work as sign language interpreters, have decided to raise their children with American Sign Language as their only form of communication. They have chosen not to pursue cochlear implantation nor support the use of hearing aids. This case raises significant questions concerning whether hearing rehabilitation should be mandated, and if there are circumstances in which parental preferences should be questioned or overridden with regard to this issue. In addition, legal concerns may be raised regarding the possible need to file a report with Child Protective Services. Although similar cases involving the Deaf community have historically favored parental rights to forego hearing rehabilitation with either cochlear implantation or hearing aids, we explore whether conclusions should be different because the parents in this case are not hearing impaired. The ethics of parental rights to refuse hearing rehabilitation are complex and strikingly context-dependent. A comprehensive appreciation of the medical, practical, and legal issues is crucial prior to intervening in such challenging situations. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  10. The Right Not To Hear: The Ethics of Parental Refusal of Hearing Rehabilitation

    PubMed Central

    Byrd, Serena; Shuman, Andrew G.; Kileny, Sharon; Kileny, Paul R.

    2015-01-01

    Objective To explore the ethics of parental refusal of auditory-oral hearing rehabilitation. Study Design Case study with medical ethical discussion and review. Methods Two young brothers present with severe-to-profound congenital sensorineural hearing loss. The parents, both of whom have normal hearing and work as sign language interpreters, have decided to raise their children with American Sign Language as their only form of communication. They have chosen not to pursue cochlear implantation nor support the use of hearing aids. Discussion This case raises significant questions concerning whether hearing rehabilitation should be mandated, and if there are circumstances in which parental preferences should be questioned or overridden with regard to this issue. In addition, legal concerns may be raised regarding the possible need to file a report with child protective services. Although similar cases involving the Deaf community have historically favored parental rights to forego hearing rehabilitation with either cochlear implantation or hearing aids, we explore whether conclusions should be different because the parents in this case are not hearing impaired. Conclusions The ethics of parental rights to refuse hearing augmentation are complex and strikingly context-dependent. A comprehensive appreciation of the medical, practical and legal issues is crucial prior to intervening in such challenging situations. PMID:21792972

  11. Inferolateral migration of hydrogel orbital implants in microphthalmia.

    PubMed

    Tao, Jeremiah P; LeBoyer, Russell M; Hetzler, Kathy; Ng, John D; Nunery, William R

    2010-01-01

    Hydrogel spheres may be useful in treating orbital hypoplasia associated with congenital microphthalmia. The authors describe migration associated with the use of these devices. The authors retrospectively reviewed 5 cases in which a hydrogel orbital expander (Osmed) was implanted to treat orbital hypoplasia in pediatric patients with congenital microphthalmia (with or without previous surgery). In all 5 cases, a lateral orbitotomy, conjunctiva-sparing approach was used to insert the hydrogel spheres. Two cases involved previously unoperated orbits; 3 patients had prior orbit or socket surgery. Inferolateral movement outside the desired central, deep orbital position occurred in all 5 cases. Four of 5 cases required further procedures to achieve an adequate orbital implant position. Inferolateral migration may occur with hydrogel spheres implanted via a lateral orbitotomy approach in microphthalmia.

  12. A subperiosteal maxillary implant causing severe osteolysis.

    PubMed

    Maï, Nguyen Tan; Jean-Baptiste, Caruhel; Hossein, Khonsari Roman

    2018-06-22

    Subperiosteal implant denture therapy was initially introduced in 1942 in Sweden and was then used worldwide for the treatment of fully edentulous maxillary or mandibular arches with advanced bone atrophy. Most authors describe decent success rates for mandibular subperiosteal implants in cases with major bone atrophy but follow-up studies for maxillary subperiosteal implants are not available. Here, we report a case of severe maxillary osteolysis secondary to the placement of a subperiosteal in-house implant. Subperiosteal implants are rarely used today but patients still carrying these devices with severe complications can be challenging to manage. New technical advances, including the use of surgical planification and additive manufacturing, may lead to a new interest in subperiosteal implants. Copyright © 2018. Published by Elsevier Masson SAS.

  13. Management of Broken Dental Implant Abutment in a Patient with Bruxism: A Rare Case Report and Review of Literature.

    PubMed

    Al-Almaie, Saad

    2017-01-01

    This rare case report describes prosthodontic complications resulting from a dental implant was placed surgically more distally in the area of the missing mandibular first molar with a cantilever effect and a crest width of >12 mm in a 59-year-old patient who had a history of bruxism. Fracture of abutment is a common complication in implant was placed in area with high occlusal forces. Inability to remove the broken abutment may most often end up in discarding the implant. Adding one more dental implant mesially to the previously placed implant, improvisation of technique to remove the broken abutment without sacrificing the osseointegrated dental implant, fabrication with cemented custom-made abutment to replace the broken abutment for the first implant, and the use of the two implants to replace a single molar restoration proved reliable and logical treatment solutions to avoid these prosthodontic complications.

  14. Cardiac implantable electronic device infection due to Mycobacterium species: a case report and review of the literature.

    PubMed

    Al-Ghamdi, Bandar; Widaa, Hassan El; Shahid, Maie Al; Aladmawi, Mohammed; Alotaibi, Jawaher; Sanei, Aly Al; Halim, Magid

    2016-08-24

    Infection of cardiac implantable electronic devices is a serious cardiovascular disease and it is associated with a high mortality. Mycobacterium species may rarely cause cardiac implantable electronic devices infection. We are reporting a case of miliary tuberculosis in an Arab patient with dilated cardiomyopathy and a cardiac resynchronization therapy-defibrillator device that was complicated with infection of his cardiac resynchronization therapy-defibrillator device. To our knowledge, this is the third case in the literature with such a presentation and all patients died during the course of treatment. This underscores the importance of early diagnosis and management. We also performed a literature review of reported cases of cardiac implantable electronic devices infection related to Mycobacterium species. Cardiac implantable electronic devices infection due to Mycobacterium species is an uncommon but a well-known entity. Early diagnosis and prompt management may result in a better outcome.

  15. Endoscopic management of complications of self-expandable metal stents for treatment of malignant esophageal stenosis and tracheoesophageal fistulas.

    PubMed

    Bor, Renáta; Fábián, Anna; Bálint, Anita; Farkas, Klaudia; Szűcs, Mónika; Milassin, Ágnes; Czakó, László; Rutka, Mariann; Molnár, Tamás; Szepes, Zoltán

    2017-08-01

    Self-expandable metal stent (SEMS) implantation may rapidly improve the symptoms of malignant esophageal stenosis and tracheoesophageal fistulas (TEF). However, dysphagia often returns subsequently and repeated endoscopic intervention may be necessary. The aims of the study were to identify the risk factors of complications, and the frequency and efficacy of repeated endoscopic interventions; and to provide technical recommendations on appropriate stent selection. We analyzed retrospectively the clinical data of 212 patients with locally advanced esophageal cancer who underwent SEMS implantation. A total of 238 SEMS implantations were performed with 99.06% technical success and 1.26% procedure-related deaths in the enrolled 212 cases. Complications occurred in 84 patients (39.62%) and in 55 cases (25.94%) repeated endoscopic procedures were required. Early reintervention 24-48 h after the stent implantations was necessary due to stent migration (12 cases), arrhythmia (2 cases), intolerable retrosternal pain (1 case) and dyspnea (1 case). An average of 1.98 repeated gastroscopies (range 1-6; median 2), 13.58 weeks (range 1.5-48; median 11) after the stent implantation were performed during the follow-up period: 37 stent repositions, 23 restent implantations, 15 endoscopic esophageal dilations and 7 stent removals. In 48 cases (87.3%) oral feeding of patients was made possible by endoscopic interventions. In a quarter of SEMS implantations, complications occur that can be successfully managed by endoscopic interventions. Our experiences have shown that individualized stent choice may substantially reduce the complications rate and make repeated endoscopic interventions easier.

  16. Immediate loading of four implants (BTLock®) in the maxilla and provisional restoration with guide-surgery (SimPlant, Materialise®): case report

    PubMed Central

    SPINELLI, D.; DE VICO, G.; SCHIAVETTI, R.; BONINO, M.; POZZI, A.; BOLLERO, P.; BARLATTANI, A.

    2010-01-01

    SUMMARY The severe atrophy of the jaws are a challenging therapeutic problem, since the increase in bone is necessary to allow the placement of a sufficient number of implants. Combining immediate functionalization with the concept of guided surgery they combine the advantages offered by the innovative surgical and prosthetic implant technique (All-on-Four®) with those of computer-assisted planning in cases of severe bone atrophy. The method used in this case report, combines these two concepts in a surgical and prosthetic protocol safe and effective for the immediate function of 4 implants to support a fixed prosthesis in completely edentulous subjects. The integration of technology with immediate function with the concept of computer-guided surgery for implant placement and rehabilitation of completely edentulous jaws is now a predictable treatment modality with implant survival comparable to the traditional protocols. PMID:23285381

  17. Clinical significance of interleukin-1 genotype in smoking patients as a predictor of peri-implantitis: A case-control study

    PubMed Central

    García-Delaney, Cristina; Sánchez-Garcés, Maria-Ángeles; Sánchez-Torres, Alba; Gay-Escoda, Cosme

    2015-01-01

    Background Interleukin-1 (IL-1) is a proinflammatory cytokine that plays an important role in the pathogenesis of periodontitis, and so it might be useful to detect high-risk cases of peri-implantitis. It has been reported that IL-1 polymorphisms and smoking habit have a synergic effect, increasing the incidence of peri-implantitis. The aim of the present study was to evaluate the relationship between IL-1 gene polymorphisms and peri-implantitis in smoking patients. Material and Methods A case-control study was performed in 27 patients with peri-implantitis and 27 patients with healthy implants. All patients included were smokers. IL-1A-C889T, IL-1B+C3953T and IL-1RN+T2018C were identified by polymerase chain reaction (PCR) amplification in order to establish a relation between these variables and the presence of peri-implantitis. A bivariate analysis was performed and odds-ratio (OR) were calculated. Results The incidence of peri-implantitis was significantly higher in patients with previous history of periodontitis (p=0.024; OR=10.9). Both groups were similar regarding IL-1A-C889T, IL-1B+C3953T and IL-1RN+T2018C genotypes. No increased risk in heavy smokers with IL-1 polymorphism was found. Conclusions IL-1 genotypes do not seem to be good predictors of peri-implantitis in the great majority of smoking patients. Furthermore, no synergic effect was found between IL-1 genotypes and heavy smokers. Patients with a previous history of periodontitis were more prone to peri-implantitis. Key words:Peri-implantitis, interleukin-1 genotype positive, case-control study, smoking. PMID:26449434

  18. Cochlear Implant: the complexity involved in the decision making process by the family.

    PubMed

    Vieira, Sheila de Souza; Bevilacqua, Maria Cecília; Ferreira, Noeli Marchioro Liston Andrade; Dupas, Giselle

    2014-01-01

    to understand the meanings the family attributes to the phases of the decision-making process on a cochlear implant for their child. qualitative research, using Symbolic Interactionism and Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semistructured interview. Nine families participated in the study (32 participants). knowledge deficit, difficulties to contextualize benefits and risks and fear are some factors that make this process difficult. Experiences deriving from interactions with health professionals, other cochlear implant users and their relatives strengthen decision making in favor of the implant. deciding on whether or not to have the implant involves a complex process, in which the family needs to weigh gains and losses, experience feelings of accountability and guilt, besides overcoming the risk aversion. Hence, this demands cautious preparation and knowledge from the professionals involved in this intervention.

  19. Multifractal spectrum and lacunarity as measures of complexity of osseointegration.

    PubMed

    de Souza Santos, Daniel; Dos Santos, Leonardo Cavalcanti Bezerra; de Albuquerque Tavares Carvalho, Alessandra; Leão, Jair Carneiro; Delrieux, Claudio; Stosic, Tatijana; Stosic, Borko

    2016-07-01

    The goal of this study is to contribute to a better quantitative description of the early stages of osseointegration, by application of fractal, multifractal, and lacunarity analysis. Fractal, multifractal, and lacunarity analysis are performed on scanning electron microscopy (SEM) images of titanium implants that were first subjected to different treatment combinations of i) sand blasting, ii) acid etching, and iii) exposition to calcium phosphate, and were then submersed in a simulated body fluid (SBF) for 30 days. All the three numerical techniques are applied to the implant SEM images before and after SBF immersion, in order to provide a comprehensive set of common quantitative descriptors. It is found that implants subjected to different physicochemical treatments before submersion in SBF exhibit a rather similar level of complexity, while the great variety of crystal forms after SBF submersion reveals rather different quantitative measures (reflecting complexity), for different treatments. In particular, it is found that acid treatment, in most combinations with the other considered treatments, leads to a higher fractal dimension (more uniform distribution of crystals), lower lacunarity (lesser variation in gap sizes), and narrowing of the multifractal spectrum (smaller fluctuations on different scales). The current quantitative description has shown the capacity to capture the main features of complex images of implant surfaces, for several different treatments. Such quantitative description should provide a fundamental tool for future large scale systematic studies, considering the large variety of possible implant treatments and their combinations. Quantitative description of early stages of osseointegration on titanium implants with different treatments should help develop a better understanding of this phenomenon, in general, and provide basis for further systematic experimental studies. Clinical practice should benefit from such studies in the long term, by more ready access to implants of higher quality.

  20. Bone-anchored titanium implants for auricular rehabilitation: case report and review of literature.

    PubMed

    Gumieiro, Emne Hammoud; Dib, Luciano Lauria; Jahn, Ricardo Schmitutz; Santos Junior, João Ferreira dos; Nannmark, Ulf; Granström, Gösta; Abrahão, Márcio

    2009-01-01

    Osseointegrated implants have acquired an important role in the prosthetic rehabilitation of patients with craniofacial defects. The main indications are lack of local tissue for autogenous reconstruction, previous reconstruction failure and selection of this technique by the patient. This paper presents a clinical case and discusses indications and advantages of the osseointegrated implant technique for retention of auricular prostheses. Case report, Universidade Federal de São Paulo (UNIFESP). A female patient received three auricular implants after surgical resection of a hemangioma in her left ear. The time taken for osseointegration of the temporal bone was three months. After fabrication of the implant-retained auricular prosthesis, the patient was monitored for 12 months. The clinical parameters evaluated showed good postoperative healing, healthy peri-implant tissue, good hygiene and no loss of implants. Good hygiene combined with thin and immobile peri-implant soft tissues resulted in minimal complications. Craniofacial implant integration appears to be site-dependent; increasing age affects osseointegration in the temporal bone. The frequency of adverse skin reactions in peri-implant tissues is generally low. The surgical technique for rehabilitation using implant-retained auricular prostheses seems to be simple. It is associated with low rates of adverse skin reactions and long-term complications. Prostheses anchored by osseointegrated implants seem to provide better retention than do prostheses supported on spectacle frames, less risk of discoloration through the use of adhesives and better esthetic results than do prostheses anchored in the surgical cavity.

  1. Changes in pelvic organ prolapse mesh mechanical properties following implantation in rats.

    PubMed

    Ulrich, Daniela; Edwards, Sharon L; Alexander, David L J; Rosamilia, Anna; Werkmeister, Jerome A; Gargett, Caroline E; Letouzey, Vincent

    2016-02-01

    Pelvic organ prolapse (POP) is a multifactorial disease that manifests as the herniation of the pelvic organs into the vagina. Surgical methods for prolapse repair involve the use of a synthetic polypropylene mesh. The use of this mesh has led to significantly higher anatomical success rates compared with native tissue repairs, and therefore, despite recent warnings by the Food and Drug Administration regarding the use of vaginal mesh, the number of POP mesh surgeries has increased over the last few years. However, mesh implantation is associated with higher postsurgery complications, including pain and erosion, with higher consecutive rates of reoperation when placed vaginally. Little is known on how the mechanical properties of the implanted mesh itself change in vivo. It is assumed that the mechanical properties of these meshes remain unchanged, with any differences in mechanical properties of the formed mesh-tissue complex attributed to the attached tissue alone. It is likely that any changes in mesh mechanical properties that do occur in vivo will have an impact on the biomechanical properties of the formed mesh-tissue complex. The objective of the study was to assess changes in the multiaxial mechanical properties of synthetic clinical prolapse meshes implanted abdominally for up to 90 days, using a rat model. Another objective of the study was to assess the biomechanical properties of the formed mesh-tissue complex following implantation. Three nondegradable polypropylene clinical synthetic mesh types for prolapse repair (Gynemesh PS, Polyform Lite, and Restorelle) and a partially degradable polypropylene/polyglecaprone mesh (UltraPro) were mechanically assessed before and after implantation (n = 5/ mesh type) in Sprague Dawley rats for 30 (Gynemesh PS, Polyform Lite, and Restorelle) and 90 (UltraPro and Polyform Lite) days. Stiffness and permanent extension following cyclic loading, and breaking load, of the preimplanted mesh types, explanted mesh-tissue complexes, and explanted meshes were assessed using a multi-axial (ball-burst) method. The 4 clinical meshes varied from each other in weight, thickness, porosity, and pore size and showed significant differences in stiffness and breaking load before implantation. Following 30 days of implantation, the mechanical properties of some mesh types altered, with significant decreases in mesh stiffness and breaking load, and increased permanent extension. After 90 days these changes were more obvious, with significant decreases in stiffness and breaking load and increased permanent extension. Similar biomechanical properties of formed mesh-tissue complexes were observed for mesh types of different preimplant stiffness and structure after 90 days implantation. This is the first study to report on intrinsic changes in the mechanical properties of implanted meshes and how these changes have an impact on the estimated tissue contribution of the formed mesh-tissue complex. Decreased mesh stiffness, strength, and increased permanent extension following 90 days of implantation increase the biomechanical contribution of the attached tissue of the formed mesh-tissue complex more than previously thought. This needs to be considered when using meshes for prolapse repair. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  2. Current aspects in reconstructive surgery for nasal cavity and paranasal sinus cancer

    NASA Astrophysics Data System (ADS)

    Shtin, V. I.; Novikov, V. A.; Gjunter, V. E.; Choinzonov, E. L.; Ryabova, A. I.; Sirkashev, V. A.; Surkova, P. V.; Vasilev, R. V.; Menkova, E. N.

    2017-09-01

    Tumors of the nasal cavity and paranasal sinuses present a challenge to treat them. A combination of surgery and radiation therapy can improve treatment outcomes in 49-56% [1, 2] of the patients with locally advanced nasal cavity and paranasal sinus cancer. The midface reconstruction poses a formidable challenge to the reconstructive surgeon due to the region's complex skeletal and soft-tissue anatomy. The rehabilitation program including the reconstruction of the resected orbital walls using the porous and mesh implants from titanium nickelid (TiNi) was developed at the Cancer Research institute jointly with the Research Institute of Medical Materials. The technique was proven effective, allowing the natural position of the eye and visual function to be preserved in 90% [1-3] of the patients. A long period of reparative processes and risk of developing inflammation in the implant area, as well as the need to decrease length of surgery, contributed to the development of a novel approach to repairing the midface bone structures using the implant based on the microporous wire and TiNi mesh. Eighteen patients with nasal cavity and paranasal sinus cancer were treated using the combined thin implants. The novel technique allowed the time of the implant installation to be reduced to 5-10 min. The structure of the implant contributed to prevention of inflammatory processes in 97% [1, 2] of cases. Thus, the natural position of the eyeball and visual function were preserved in 100% [1, 3, 4] of patients. The use of the TiNi implants in reconstructive surgery for patients with nasal cavity and paranasal sinus cancer led to reduced time of surgery and rehabilitation, increased level of social adaptation of patients and improved cosmetic and functional results.

  3. Implant salvage in breast reconstruction with severe peri-prosthetic infection.

    PubMed

    Meybodi, Farid; Sedaghat, Negin; French, James; Keighley, Caitlin; Mitchell, David; Elder, Elisabeth

    2017-12-01

    Although treatment of mild peri-prosthetic infection in implant-based breast reconstruction results in high rates of resolution, successful management of severe peri-prosthetic infection remains a significant challenge. In this case series, a protocol utilizing a novel dressing - negative pressure wound therapy with instillation (NPWTi) - for the management of severe peri-prosthetic infection in breast reconstruction patients is described. This is an operative technique involving: (i) explantation of the breast prosthesis and application of the NPWTi dressing to the implant pocket; (ii) change of the NPWTi dressing; (iii) intraoperative fluid/tissue cultures; and (iv) reimplantation of the breast prosthesis when cultures yield no growth. This protocol was utilized in six cases of severe peri-prosthetic infection in five patients with immediate breast reconstruction for breast cancer or risk-reducing surgery. Cultures of fluid/tissue grew typical and/or unusual organisms. Only one case did not yield an organism. The hospital length of stay upon completion of the protocol ranged from 7-16 days (mean, 12 days). Successful implant salvage was achieved in five of six cases. The protocol was aborted in one case to allow for completion of adjuvant chemotherapy. Early findings from this case series suggest that in cases of severe peri-prosthetic infection this novel operative protocol may result in successful implant salvage for breast reconstruction patients. Further studies are needed to more fully elaborate the role of NPWTi to achieve implant salvage in challenging cases of peri-prosthetic infection. © 2015 Royal Australasian College of Surgeons.

  4. Diagnostic performance of swab PCR as an alternative to tissue culture methods for diagnosing infections associated with fracture fixation devices.

    PubMed

    Omar, Mohamed; Suero, Eduardo M; Liodakis, Emmanouil; Reichling, Moritz; Guenther, Daniel; Decker, Sebastian; Stiesch, Meike; Krettek, Christian; Eberhard, Jörg

    2016-07-01

    Molecular procedures could potentially improve diagnoses of orthopaedic implant-related infections, but are not yet clinically implemented. Analysis of sonication fluid shows the highest sensitivity for diagnosing implant infections in cases of revision surgery with implant removal. However, there remains controversy regarding the best method for obtaining specimens in cases of revision surgery with implant retention. Tissue culture is the most common diagnostic method for pathogen identification in such cases. Here we aimed to assess the diagnostic performance of swab PCR analysis compared to tissue culture from patients undergoing revision surgery of fracture fixation devices. We prospectively investigated 62 consecutive subjects who underwent revision surgery of fracture fixation devices during a two-year period. Tissue samples were collected for cultures, and swabs from the implant surface were obtained for 16S rRNA PCR analysis. Subjects were classified as having an implant-related infection if (1) they presented with a sinus tract or open wound in communication with the implant; or (2) purulence was encountered intraoperatively; or (3) two out of three tissue cultures tested positive for the presence of the same pathogen. Tissue culture and swab PCR results from the subjects were used to calculate the sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), and area under the ROC curve (AUC) for identifying an orthopaedic implant-related infection. Orthopaedic implant-related infections were detected in 51 subjects. Tissue culture identified infections in 47 cases, and swab PCR in 35 cases. Among the 11 aseptic cases, tissue culture was positive in 2 cases and swab PCR in 4 cases. Tissue culture showed a significantly higher area under the ROC curve for diagnosing infection (AUC=0.89; 95% CI, 0.67-0.96) compared to swab PCR (AUC=0.66; 95% CI, 0.46-0.80) (p=0.033). Compared to swab PCR, tissue culture showed better performance for diagnosing orthopaedic implant-related infection. Although molecular methods are expected to yield higher diagnostic accuracy than cultures, it appears that the method of obtaining specimens plays an important role. Improved methods of specimen collection are required before swab PCR can become a reliable alternative to tissue-consumptive methods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Implant failure and history of failed endodontic treatment: A retrospective case-control study.

    PubMed

    Chatzopoulos, Georgios S; Wolff, Larry F

    2017-11-01

    Residual bacterial biofilm and/or bacteria in planktonic form may be survived in the bone following an extraction of an infected tooth that was endodontically treated unsuccessfully Failed endodontic treatment may be associated with failure of implants to osseointegrate in the same sites. Therefore, the aim of this retrospective case-control study is to examine the risk of implant failure in previous failed endodontic sites. This retrospective case-control study is based on 94 dental records of implants placed at the University of Minnesota School of Dentistry. Dental records of patients who received an implant in sites with previously failed endodontic therapy in the dental school were identified from the electronic database, while control subjects were obtained from the same pool of patients with the requirement to have received an implant in a site that was not endodontically treated. The mean age of the population was 62.89±14.17 years with 57.4% of the sample being females and 42.6% of them being males. In regards to the socio-economic status and dental insurance, 84.0% of this population was classified as low socio-economic status and 68.1% had dental insurance. Tobacco use was self-reported by 9.6% and hypercholesterolemia was the most prevalent systemic medical condition. Dental implant failure was identified in two of the included records (2.1%), both of which were placed in sites with a history of failed endodontic treatment. Within the limitations of this retrospective case-control study, further investigation with a larger population group into implant failure of sites that previously had unsuccessful endodontic treatment would be warranted. Implant failure may be associated with a history of failed endodontic treatment. Key words: Implantology, endodontics, osseointegration, treatment outcome, case-control study.

  6. Biomechanical optimization of implant diameter and length for immediate loading: a nonlinear finite element analysis.

    PubMed

    Kong, Liang; Gu, Zexu; Li, Tao; Wu, Junjie; Hu, Kaijin; Liu, Yanpu; Zhou, Hongzhi; Liu, Baolin

    2009-01-01

    A nonlinear finite element method was applied to examine the effects of implant diameter and length on the maximum von Mises stresses in the jaw, and to evaluate the maximum displacement of the implant-abutment complex in immediate-loading models. The implant diameter (D) ranged from 3.0 to 5.0 mm and implant length (L) ranged from 6.0 to 16.0 mm. The results showed that the maximum von Mises stress in cortical bone was decreased by 65.8% under a buccolingual load with an increase in D. In cancellous bone, it was decreased by 71.5% under an axial load with an increase in L. The maximum displacement in the implant-abutment complex decreased by 64.8% under a buccolingual load with an increase in D. The implant was found to be more sensitive to L than to D under axial loads, while D played a more important role in enhancing its stability under buccolingual loads. When D exceeded 4.0 mm and L exceeded 11.0 mm, both minimum stress and displacement were obtained. Therefore, these dimensions were the optimal biomechanical selections for immediate-loading implants in type B/2 bone.

  7. Unique presentation of Twiddler’s syndrome

    PubMed Central

    Parikh, Valay; Barsoum, Emad A; Morcus, Rewais; Azab, Basem; Lafferty, James; Kohn, Jeffrey

    2013-01-01

    We present a rare case of Twiddler’s syndrome diagnosed in an asymptomatic patient on a routine follow up. This case reiterates the need for frequent monitoring of the implanted device. In addition, it was detected 4 years after implantation of an automatic implantable cardioverter defibrillator. This late representation is extremely uncommon. PMID:23802049

  8. Oral Cancer around Dental Implants Appearing in Patients with\\without a History of Oral or Systemic Malignancy: a Systematic Review.

    PubMed

    Pinchasov, Ginnady; Haimov, Haim; Druseikaite, Monika; Pinchasov, Daniel; Astramskaite, Inesa; Sarikov, Rafael; Juodzbalys, Gintaras

    2017-01-01

    The purpose of this article is to systematically review the circumstance of oral cancer around osseointegrated dental implants. An electronic literature search was conducted through the MEDLINE (PubMed) and EMBASE databases. The search was restricted for articles published during the last 21 years from January 1996 to April 2017 and articles were limited to English language. A total of 35 articles were reviewed, and 19 of the most relevant articles that are suitable to the criteria were selected. Case reports were analysed when oral cancer was present in patients with dental implants. Finally, the present data included 28 patients. A direct link between dental implants and oral cancer was not found. It was observed that there were no significant differences in number of incidences of oral cancer between patients with history of malignancy and those without. More research should be made to document such cases. It was noticed that in many cases oral cancer around dental implant present itself as peri-implantitis, correct differential diagnosis is essential in such cases.

  9. Treatment of Implant Exposure due to Skin Necroses after Skin Sparing Mastectomy: Initial Experiences Using a Not Selective Random Epigastric Flap.

    PubMed

    Echazarreta-Gallego, Estíbaliz; Pola-Bandrés, Guillermo; Arribas-Del Amo, María Dolores; Gil-Romea, Ismael; Sousa-Domínguez, Ramón; Güemes-Sánchez, Antonio

    2017-10-01

    Breast prostheses exposure is probably the most devastating complication after a skin sparing mastectomy (SSM) and implant-based, one-stage, breast reconstruction. This complication may occur in the immediate post-operative period or in the weeks and even months after the procedure. In most cases, the cause is poor skin coverage of the implant due to skin necrosis. Eight consecutive cases of implant exposure (or risk of exposure) due to skin necrosis in SSM patients over a period of 5 years, all patients were treated using a random epigastric rotation flap, executed by the same medical team. A random epigastric flap (island or conventional rotation flap) was used to cover the skin defect. All the patients completed the procedure and all prostheses were saved; there were no cases of flap necrosis or infection. Cases of skin necrosis after SSM and immediate implant reconstruction, in which the implant is at risk of exposure, can be successfully treated with a random epigastric rotation flap.

  10. Intraindividual variation in core microbiota in peri-implantitis and periodontitis

    PubMed Central

    Maruyama, Noriko; Maruyama, Fumito; Takeuchi, Yasuo; Aikawa, Chihiro; Izumi, Yuichi; Nakagawa, Ichiro

    2014-01-01

    The oral microbiota change dramatically with each part of the oral cavity, even within the same mouth. Nevertheless, the microbiota associated with peri-implantitis and periodontitis have been considered the same. To improve our knowledge of the different communities of complex oral microbiota, we compared the microbial features between peri-implantitis and periodontitis in 20 patients with both diseases. Although the clinical symptoms of peri-implantitis were similar to those of periodontitis, the core microbiota of the diseases differed. Correlation analysis revealed the specific microbial co-occurrence patterns and found some of the species were associated with the clinical parameters in a disease-specific manner. The proportion of Prevotella nigrescens was significantly higher in peri-implantitis than in periodontitis, while the proportions of Peptostreptococcaceae sp. and Desulfomicrobium orale were significantly higher in periodontitis than in peri-implantitis. The severity of the peri-implantitis was also species-associated, including with an uncultured Treponema sp. that correlated to 4 clinical parameters. These results indicate that peri-implantitis and periodontitis are both polymicrobial infections with different causative pathogens. Our study provides a framework for the ecologically different bacterial communities between peri-implantitis and periodontitis, and it will be useful for further studies to understand the complex microbiota and pathogenic mechanisms of oral polymicrobial diseases. PMID:25308100

  11. Identification of vacancy-oxygen complexes in oxygen-implanted silicon probed with slow positrons

    NASA Astrophysics Data System (ADS)

    Fujinami, M.; Miyagoe, T.; Sawada, T.; Suzuki, R.; Ohdaira, T.; Akahane, T.

    2004-04-01

    Defects and their annealing behavior for low (2×1015/cm2) and high (1.7×1018/cm2) doses of 180 keV oxygen-implanted silicon have been investigated by the coincidence Doppler broadening (CDB) and lifetime measurements in variable-energy positron annihilation spectroscopy. In the low-dose sample, divacancies are induced throughout the entire implantation region. In the vacancy-oxygen coexisting region (300-500 nm depths), by raising the annealing temperature to 600 °C, vacancy-oxygen VxOy complexes with one vacant site are formed and, simultaneously, the migration of oxygen begins to takes place. In the vacancy-rich region (-200 nm depths), the evolution of simple vacancy clusters to V4 is mainly observed below 600 °C. From CDB and lifetime measurements, it has been proven that after annealing at 800 °C, the VxOy complexes are formed throughout the implanted region and they contain four vacant sites and a high ratio of y to x. On the other hand, high-dose implantation at 550 °C produces the VxOy complexes with a lifetime of a 430 ps in the near-surface region (less than 200 nm deep) and annealing at 1100 °C leads to the highest ratio of y to x. These complexes cannot be annealed out even by annealing at 1350 °C, and their structure is found to be very similar to that for the electron-irradiated amorphous SiO2.

  12. Correction of irregular and induced regular corneal astigmatism with toric IOL after posterior segment surgery: a case series.

    PubMed

    Kolozsvári, Bence L; Losonczy, Gergely; Pásztor, Dorottya; Fodor, Mariann

    2017-01-13

    Toric intraocular lens (IOL) implantation can be an effective method for correcting corneal astigmatism in patients with vitreoretinal diseases and cataract. Our purpose is to report the outcome of toric IOL implantation in two cases - a patient with scleral-buckle-induced regular corneal astigmatism and a patient with keratoconus following pars plana vitrectomy. As far as we are aware, there are no reported cases of toric IOL implantation in a vitrectomized eye with keratoconus nor of toric IOL implantation in patients with scleral-buckle-induced regular corneal astigmatism. Two patients with myopia and high corneal astigmatism underwent cataract operation with toric IOL implantation after posterior segment surgery. Myopia and high astigmatism (>2.5 diopter) were caused by previous scleral buckling in one case and by keratoconus in the other case. Pre- and postoperative examinations during the follow-up of included uncorrected and spectacle corrected distance visual acuity (UCDVA/CDVA), automated kerato-refractometry (Topcon), Pentacam HR, IOL Master (Zeiss) axial length measurements and fundus optical coherence tomography (Zeiss). One year postoperatively, the UCDVA and CDVA were 20/25 and 20/20 in both cases, respectively. The absolute residual refractive astigmatism was 1.0 and 0.75 Diopters, respectively. The IOL rotation was within 3° in both eyes, therefore IOL repositioning was not necessary. Complications were not observed in our cases. These cases demonstrate that toric IOL implantation is a predictable and safe method for the correction of high corneal astigmatism in complicated cases with different origins. Irregular corneal astigmatism in keratoconus or scleral-buckle-induced regular astigmatisms can be equally well corrected with the use of toric IOL during cataract surgery. Previous scleral buckling or pars plana vitrectomy seem to have no impact on the success of the toric IOL implantation, even in keratoconus. IOL rotational stability and refractive predictability in patients with a previous vitreoretinal surgery can be as good as in uncomplicated cases.

  13. Corneal toxicity after Ozurdex(®) migration into anterior chamber.

    PubMed

    Bernal, L; Estévez, B

    2016-06-01

    To describe a case of corneal toxicity after migration of a dexamethasone implant into the anterior chamber. A 62-year-old man with aphakia and a history of vitrectomy received a dexamethasone implant for a refractory Irvine-Gass syndrome. Thirty days later, the implant migrated into the anterior chamber causing endothelial contact with secondary corneal oedema that justified the removal of the implant without resolution of the oedema. Clinical tolerability to dislocated implant is poor in cases with pre-existing corneal oedema, and because of this, it must be removed early. In cases of aphakia and vitrectomy, the increased risk of Ozurdex(®) dislocation justifies performing a prior endothelial count. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  14. Telescopic crowns as attachments for implant supported restorations: a case series.

    PubMed

    Hoffmann, Oliver; Beaumont, Christian; Tatakis, Dimitris N; Zafiropoulos, Gregory-George

    2006-01-01

    The use of dental implants to support mandibular or maxillary overdentures is a widely used treatment modality. Advantages are an increase in retention, an increase in chewing ability, and easy access for oral hygiene procedures. While telescopic and conical crowns have been used for decades to connect natural teeth to overdentures, not many cases have been reported in the literature of telescopic crowns placed on implants to support overdentures. This article describes 7 patients with overdentures supported by telescopic crowns who received 65 implants (ITI Straumann). The cases presented in this report have been in function for up to 4.5 years. During that time no adverse events were reported. The use of telescopic crowns as attachments for implant-supported overdentures may be a viable treatment option.

  15. Human Histologic Evidence of Reosseointegration Around an Implant Affected with Peri-implantitis Following Decontamination with Sterile Saline and Antiseptics: A Case History Report.

    PubMed

    Fletcher, Paul; Deluiz, Daniel; Tinoco, Eduardo Mb; Ricci, John L; Tarnow, Dennis P; Tinoco, Justine Monnerat

    The treatment of peri-implant disease is one of the most controversial topics in implant dentistry. The multifactorial etiology and the myriad proposed techniques for managing the problem make successful decontamination of an implant surface affected by peri-implantitis one of the more unpredictable challenges dental practitioners have to face. This article presents the first known published case report demonstrating human histologic evidence of reosseointegration using a plastic curette for mechanical debridement and dilute sodium hypochlorite, hydrogen peroxide, and sterile saline for chemical detoxification. Guided bone regeneration in the infrabony component of the peri-implantitis lesion was accomplished using calcium sulfate and bovine bone as grafting materials and a porcine collagen barrier for connective tissue and epithelial exclusion.

  16. Simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome.

    PubMed

    Alsanosi, A A

    2015-09-01

    To report a rare case of simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome. Case report. A five-month-old boy with Usher syndrome and congenital profound bilateral deafness underwent simultaneous bilateral cochlear implantation. The decision to perform implantation in such a young child was based on his having a supportive family and the desire to foster his audiological development before his vision deteriorated. The subject experienced easily resolvable intra- and post-operative adverse events, and was first fitted with an externally worn audio processor four weeks after implantation. At 14 months of age, his audiological development was age-appropriate. Simultaneous bilateral cochlear implantation is possible, and even advisable, in children as young as five months old when performed by an experienced implantation team.

  17. Success and High Predictability of Intraorally Welded Titanium Bar in the Immediate Loading Implants

    PubMed Central

    Fogli, Vaniel; Camerini, Michele; Carinci, Francesco

    2014-01-01

    The implants failure may be caused by micromotion and stress exerted on implants during the phase of bone healing. This concept is especially true in case of implants placed in atrophic ridges. So the primary stabilization and fixation of implants are an important goal that can also allow immediate loading and oral rehabilitation on the same day of surgery. This goal may be achieved thanks to the technique of welding titanium bars on implant abutments. In fact, the procedure can be performed directly in the mouth eliminating possibility of errors or distortions due to impression. This paper describes a case report and the most recent data about long-term success and high predictability of intraorally welded titanium bar in immediate loading implants. PMID:24963419

  18. Correction of Large Oro-antral Communications From Previously Failed Implant Treatment: Reconstruction of Hard and Soft Tissues.

    PubMed

    Petrungaro, Paul S; Gonzalez, Santiago; Villegas, Carlos

    2018-02-01

    As dental implants become more popular for the treatment of partial and total edentulism and treatment of "terminal dentitions," techniques for the management of the atrophic posterior maxillae continue to evolve. Although dental implants carry a high success rate long term, attention must be given to the growing numbers of revisions or retreatment of cases that have had previous dental implant treatment and/or advanced bone replacement procedures that, due to either poor patient compliance, iatrogenic error, or poor quality of the pre-existing alveolar and/or soft tissues, have led to large osseous defects, possibly with deficient soft-tissue volume. In the posterior maxillae, where the poorest quality of bone in the oral cavity exists, achieving regeneration of the alveolar bone and adequate volume of soft tissue remains a complex procedure. This is made even more difficult when dealing with loss of dental implants previously placed, aggressive bone reduction required in various implant procedures, and/or residual sinus infections precluding proper closure of the oral wound margins. The purpose of this article is to outline a technique for the total closure of large oro-antral communications, with underlying osseous defects greater than 15 mm in width and 30 mm in length, for which multiple previous attempts at closure had failed, to achieve not only the reconstruction of adequate volume and quality of soft tissues in the area of the previous fistula, but also total regeneration of the osseous structures in the area of the large void.

  19. The side effects and complications of percutaneous iodine-125 seeds implantation under CT-guide for patients with advanced pancreatic cancer.

    PubMed

    Lv, Wei-Fu; Lu, Dong; Xiao, Jing-Kun; Mukhiya, Gauri; Tan, Zhong-Xiao; Cheng, De-Lei; Zhou, Chun-Ze; Zhang, Xing-Min; Zhang, Zheng-Feng; Hou, Chang-Long

    2017-12-01

    The present study investigates the side effects and complications of computed tomography (CT)-guided percutaneous iodine-125 (I-125) seeds implantation for advanced pancreatic cancer. The clinical data were retrospectively analyzed for patients treated with implantation of I-125 seeds under CT-guide in our hospital from May 2010 to April 2015. The side effects and complications were collected and their possible reasons were analyzed. A total of 78 patients were enrolled. The side effects were categorized as fever in 29 cases (37.18%), abdominal pain in 26 cases (33.33%), nausea and vomiting in 9 cases (11.54%), diarrhea in 5 cases (6.41%), and constipation in 4 cases (5.13%). Complications were composed of pancreatitis in 9 cases (11.54%), infection in 5 cases (6.41%), seed migration in 2 cases (2.56%), intestinal perforation in 1 case (1.28%), and intestinal obstruction in 1 case. The incidence of complication was 23.08% (18/78). The difference in incidence of complication was statistically significant between patients implanted with ≤27 seeds and those with >27 seeds (P = .032). The side effects and complications frequently occur in implantation of I-125 seeds for patients with advanced pancreatic cancer. More concern should be given to the patients treated by this technique. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  20. Live birth in a woman with recurrent implantation failure and adenomyosis following transfer of refrozen-warmed embryos.

    PubMed

    Safari, Somayyeh; Faramarzi, Azita; Agha-Rahimi, Azam; Khalili, Mohammad Ali

    2016-09-01

    The aim was to report a healthy live birth using re-vitrified-warmed cleavage-stage embryos derived from supernumerary warmed embryos after frozen embryo transfer (ET) in a patient with recurrent implantation failure (RIF). The case was a 39-year-old female with a history of polycystic ovarian syndrome and adenomyosis, along with RIF. After ovarian hyperstimulation, 33 cumulus-oocyte complexes were retrieved and fertilized with conventional in vitro fertilization and intracytoplasmic sperm injection. Because of the risk of ovarian hyperstimulation syndrome, 16 grade B and C embryos were vitrified. After 3 and 6 months, 3 and 4 B-C warmed embryos were transferred to the uterus, respectively. However, implantation did not take place. Ten months later, four embryos were warmed, two grade B 8-cell embryos were transferred, and two embryos were re-vitrified. One year later, the two re-vitrified cleavage-stage embryos were warmed, which resulted in a successful live birth. This finding showed that following first warming, it is feasible to refreeze supernumerary warmed embryos for subsequent ET in patients with a history of RIF.

  1. Case studies on local orthodontic traction by minis-implants before implant rehabilitation

    PubMed Central

    Shen, Pei; Xu, Wei-Feng; Ma, Zhi-Gui; Zhang, Shan-Yong; Zhang, Ying

    2015-01-01

    Objective: Dentition defect with malocclusion is a common occurrence in the clinical work. To restore proper occlusion, preprosthetic corrections of these malposed teeth are often indispensible. The use of orthodontic mini-implants as temporary anchorage devices provides a plausible treatment for those patients with local problems. The aim of this study was to present two cases using local orthodontic traction in conjunction with mini-implants to provide necessary conditions for implant rehabilitation in three dimensional space. Clinical consideration: Two cases who had dentition defect with malocclusion were included in the present study. As both of them rejected crown reduction or orthodontics treatment, local orthodontic traction by mini-implants was used to restore normal space for implant rehabilitation in three dimensions. Careful mechanics analysis and personalized mechanical device were under consideration. The results showed that the biological responses of the corrected teeth and the surrounding bony structures appeared normal and acceptable. Moreover the patients achieved an ideal local occlusion with a short treatment time. Conclusion: In conclusion local orthodontic traction by mini-implants was a less-invasive and short-term method with favorable effects and less necessary occlusal adjustments. PMID:26221389

  2. Cochlear implantation in children with Jervell and Lange-Nielsen syndrome - a cautionary tale.

    PubMed

    Broomfield, Stephen J; Bruce, Iain A; Henderson, Lise; Ramsden, Richard T; Green, Kevin M J

    2012-08-01

    Jervell and Lange-Nielsen (JLN) syndrome is a rare cause of congenital profound hearing loss associated with a prolonged QT interval on the electrocardiogram. Children presenting for cochlear implantation with this condition may be asymptomatic but are at risk of sudden death. SCREENING AND SUBSEQUENT: careful management is therefore required to ensure a successful outcome. We present our experience of cochlear implantation in children with JLN syndrome, including two who died unexpectedly, and suggest a protocol for management of such cases. Clinical presentation Four cases of cochlear implantation in JLN syndrome are described. None had any previous cardiological family history. Two were diagnosed pre-operatively but, despite appropriate management under a cardiologist, died from cardiac arrest; the first in the perioperative period following reimplantation for infection, and the second unrelated to his cochlear implant surgery. The other two patients were diagnosed only subsequent to their implantation and continue to use their implants successfully. These cases highlight the variation in presentation of JLN syndrome, and the spectrum of disease severity that exists. Our protocol stresses the importance of careful assessment and counselling of parents by an experienced implant team.

  3. In vivo confocal microscopic investigation of the cornea after autologous implantation of lenticules obtained through small incision lenticule extraction for treatment of hyperopia.

    PubMed

    Li, Meiyan; Li, Meng; Sun, Ling; Han, Tian; Ding, Lan; Xiang, Jun; Zhou, Xingtao

    2018-01-01

    To investigate re-innervation in the implanted lenticule, as well as changes to the cornea, after correcting hyperopia with an autologous implantation of a lenticule obtained through small incision lenticule extraction (SMILE). This study retrospectively analysed re-innervation in the implanted lenticule, as well as microscopic morphological changes in the corneal architecture of the recipient cornea in five patients (with myopia in one eye and hyperopia in the contralateral eye) who received SMILE in the myopic eye and femtosecond laser in situ keratomileusis (FS-LASIK) combined with lenticule implantation in the contralateral hyperopic eye. Re-innervation in the implanted lenticule, as well as microscopic morphological changes in corneal architecture, were evaluated by in vivo confocal microscopy. One patient was examined at postoperative week six, two were examined at postoperative month two, one was examined at postoperative month nine, and one was examined at postoperative month 12. Partial subbasal nerve fibre regeneration was detected in two patients (Case 4 who was examined at postoperative month nine and Case 5 who was examined at postoperative month 12). Regenerated and branched nerve fibres were detected in the implanted lenticule in Case 5 who was examined at postoperative month 12. Both the anterior and posterior interfaces showed an absence or decrease of keratocytes and the presence of small particles of various brightnesses. Keratocytes in the implanted lenticule presented abnormal morphology in size and shape after surgery in all treated eyes, but showed partial morphological recovery in two patients (Case 4 who was examined at postoperative month nine and Case 5 who was examined at postoperative month 12). These preliminary findings suggest that nerve fibres will regenerate into the implanted lenticule after autologous lenticule implantation. Keratocytes in lenticules demonstrated a gradual return to a normal morphology. © 2017 Optometry Australia.

  4. Analysis of 30 breast implant rupture cases.

    PubMed

    Tark, Kwan Chul; Jeong, Hii Sun; Roh, Tae Suk; Choi, Jong Woo

    2005-01-01

    Breast implants used for augmentation mammoplasty or breast reconstruction could rupture from various causes such as trauma or spontaneous failure. The objectives of this study were to investigate the relationships between the causes of implant rupture and the degree of capsular contracture, and then to evaluate the relative efficacies of specific signs on magnetic resonance imaging (MRI) known to be beneficial for diagnosing the rupture. A retrospective review identified patients with prosthetic implant rupture or impending rupture treated by the senior author. The 30 cases of implant rupture available for review were classified into two groups: intracapsular and extracapsular ruptures. The 30 cases of breast implant ruptures were analyzed with respect to the clinical symptoms and signs, the causes of rupture, the degree of capsular contracture, and therapeutic plans. Among the 30 cases, 14 patients who had undergone MRI during the diagnostic period were analyzed with respect to the relationships between MRI readings and operative findings. Spontaneous rupture of membranes was most common (80%), followed by failure because of trauma (7%) and valve or implant base (4%). The symptoms during implant rupture were contour deformity, palpated mass-like lesions, pain, and focal inflammation. According to the analysis of specific MRI signs, the sensitivity and specificity of the linguine sign were 87% and 100%, respectively, for intracapsular rupture. For extracapsular rupture, the sensitivity and specificity of the linguine sign were, respectively, 67% and 75%. The sensitivity and specificity of the rat-tail sign and tear drop sign were 14% and 50%, respectively. Breast implant rupture was correlated with the degree of capsular contracture in our study. Among the various specific MRI signs used in diagnosing the rupture, the linguine sign was reliable and had a high sensitivity and specificity, especially in cases of intracapsular rupture. On the other hand, the rat-tail and tear drop signs were nonspecific signs for diagnosing the rupture of breast implant.

  5. [Clinical experiences after implantation of various lens types in silicon oil tamponade].

    PubMed

    Effert, R; Lommatzsch, A; Wessing, A

    1996-06-01

    A tamponade of the vitreous space with silicone oil will obligatory lead to cataract after 6 to 12 months. Today it is easily possible, to implant an artificial lense in silicone oil filled eyes. However the combination of an artificial lense and silicone oil will lead to a strong inflammation in the anterior segment of the eye. 22 pseudophacic patients with silicone oil tamponade were examined 2 to 6 months after the operation. In 12 patients simple artificial lenses were implanted, in 10 patients heparin modified lenses were implanted. In 10 cases the lens was implanted followed by the insufflation of silicone oil in the vitreous cavity, in 2 cases a lens was implanted in a silicone oil filled eye and the silicon oil was not removed. In 8 cases the implantation of the artificial lens has been performed some months to years before the insufflation of the silicone oil. The indication for the silicon oil tamponade was a PVR retinal detachment in all cases. The following parameters were examined: Reaction of the pupil to light, pupil round or oval in miosis, examination of the fundus peripherie possible after mydriasis, fixation of the iris with parts of the capsula or with the anterior surface of the lens? In addition in 12 cases the postoperative refraction was compared with the results of the biometry, which was performed before the operation. In the cases with a simple lens in about 50% an incomplete miosis or an oval pupil because of fixation of the iris with parts of the capsula or with the anterior surface of the lense could be observed. In the cases with heparin modified lenses these complications could be observed in 20%. In all cases a strong opacification of the capsula was seen. In 8 of 12 cases with combined procedure a small hyperopia was measured, in 4 cases a large deviation was measured. The implantation of an artificial lens in silicone oil filled eyes is an alternative to the aphacic status with an Ando Iridectomy. Obviously heparin modified lenses have advantages in these cases. Because of the strong cataract formation we suggest to remove the anterior and the posterior capsula in the first operative session and to implant the haptics of the lens into the sulcus. Because of the high rate of complications generally first a stable retina condition should be reached before the implanation of an artificial lens is performed.

  6. Successful implant placement in a Case of Florid Cemento-osseous Dysplasia: a case report and literature review.

    PubMed

    Esfahanizadeh, Nasrin; Yousefi, Hila

    2018-02-06

    Florid cemento-osseus dysplasia (FCOD) has been described as a reactive process in which normal bone is replaced by fibrous connective tissues and cementum-like materials. Radiographically it appears as dense, lobulated masses, often occurring bilaterally with symmetric involvement. In this case report a successful implant placement has been reported in a 62-year-old Caucasian woman with a chief complaint of mandibular partial edentulous. Radiographic images showed the bilateral radio-opaque lesions in edentulous regions of mandible, and mandibular anterior teeth alike. All mandibular teeth were vital and no root resorption was detected. The findings of X-ray images were attributable to FCOD. A highly conservative step-by-step two-stage implant surgery was performed. After 6 months the implants loaded with fixed prosthesis. 2, 4,6,12 and 18 months after the surgery radiographic images were taken, which revealed an optimal functional rehabilitation and complete integration of implants. This report confirms that treating the edentulous area near the FCOD lesions could be planned, if conservative and step-by-step implant placement been considered. To the best of our knowledge, a case of FCOD with successful implant placement has not been reported previously. More studies in more patients are needed to confirm results of such a therapeutic modality.

  7. Risk of lymphoma in women with breast implants: analysis of clinical studies.

    PubMed

    Largent, Joan; Oefelein, Michael; Kaplan, Hilton M; Okerson, Ted; Boyle, Peter

    2012-05-01

    Large studies suggest that the overall rate of lymphoma in women with breast implants is no greater than in the general population; clinical reports suggest an association between breast implants and the rare non-Hodgkin lymphoma, anaplastic large cell lymphoma (ALCL). Observed cases of lymphoma reported in Allergan-sponsored breast implant clinical studies were compared with expected cases on the basis of the incidence of lymphoma among women in the National Cancer Institute's Surveillance Epidemiology and End Results program, using standardized incidence ratios (SIRs) and 95% confidence intervals (CIs). In clinical studies, there were 28 observed cases of lymphoma among 89 382 patients and 204 682 person-years of follow-up compared with 43 expected cases [SIR: 28/43=0.65 (95% CI: 0.43-0.94), P=0.02]. SIRs were calculated stratifying by baseline cancer history: women without prior cancer [SIR: 17/24=0.70 (95% CI: 0.41-1.13), P=0.17] and women with prior cancer [SIR: 11/14=0.79 (95% CI: 0.39-1.41), P=0.52]. SIRs were calculated by implant shell type: textured shell implants [SIR: 16/23=0.70 (95% CI: 0.40-1.13), P=0.16] and smooth shell implants [SIR: 12/19=0.63 (95% CI: 0.33-1.10), P=0.12]. Surveillance Epidemiology and End Results reported 12 cases of primary breast ALCL in women between 1996 and 2007 without a history of cancer, for an average annual incidence of 4.28 (95% CI: 3.51-5.05)/100 million women in the US - these women may or may not have breast implants. In clinical studies, three ALCL cases were reported in women with breast implants and a history of breast cancer, yielding a crude incidence rate of 1.46 (95% CI: 0.30-4.3)/100 000 person-years. Large clinical studies, based on over 200 000 person-years of follow-up, suggest no evidence of an increased risk of lymphoma among women who have received breast implants.

  8. Cochlear Implant: the complexity involved in the decision making process by the family1

    PubMed Central

    Vieira, Sheila de Souza; Bevilacqua, Maria Cecília; Ferreira, Noeli Marchioro Liston Andrade; Dupas, Giselle

    2014-01-01

    Objective to understand the meanings the family attributes to the phases of the decision-making process on a cochlear implant for their child. Method qualitative research, using Symbolic Interactionism and Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semistructured interview. Nine families participated in the study (32 participants). Results knowledge deficit, difficulties to contextualize benefits and risks and fear are some factors that make this process difficult. Experiences deriving from interactions with health professionals, other cochlear implant users and their relatives strengthen decision making in favor of the implant. Conclusion deciding on whether or not to have the implant involves a complex process, in which the family needs to weigh gains and losses, experience feelings of accountability and guilt, besides overcoming the risk aversion. Hence, this demands cautious preparation and knowledge from the professionals involved in this intervention. PMID:25029052

  9. Using stereophotogrammetric technology for obtaining intraoral digital impressions of implants.

    PubMed

    Pradíes, Guillermo; Ferreiroa, Alberto; Özcan, Mutlu; Giménez, Beatriz; Martínez-Rus, Francisco

    2014-04-01

    The procedure for making impressions of multiple implants continues to be a challenge, despite the various techniques proposed to date. The authors' objective in this case report is to describe a novel digital impression method for multiple implants involving the use of stereophotogrammetric technology. The authors present three cases of patients who had multiple implants in which the impressions were obtained with this technology. Initially, a stereo camera with an infrared flash detects the position of special flag abutments screwed into the implants. This process is based on registering the x, y and z coordinates of each implant and the distances between them. This information is converted into a stereolithographic (STL) file. To add the soft-tissue information, the user must obtain another STL file by using an intraoral or extraoral scanner. In the first case presented, this information was acquired from the plaster model with an extraoral scanner; in the second case, from a Digital Imaging and Communication in Medicine (DICOM) file of the plaster model obtained with cone-beam computed tomography; and in the third case, through an intraoral digital impression with a confocal scanner. In the three cases, the frameworks manufactured from this technique showed a correct clinical passive fit. At follow-up appointments held six, 12 and 24 months after insertion of the prosthesis, no complications were reported. Stereophotogrammetric technology is a viable, accurate and easy technique for making multiple implant impressions. Clinicians can use stereophotogrammetric technology to acquire reliable digital master models as a first step in producing frameworks with a correct passive fit.

  10. Poly Implant Prothèse (PIP) incidence of rupture: a retrospective MR analysis in 64 patients.

    PubMed

    Scotto di Santolo, Mariella; Cusati, Bianca; Ragozzino, Alfonso; Dell'Aprovitola, Nicoletta; Acquaviva, Alessandra; Altiero, Michele; Accurso, Antonello; Riccardi, Albina; Imbriaco, Massimo

    2014-12-01

    The purpose of this retrospective study was to describe the magnetic resonance imaging (MRI) features of Poly Implant Prothèse (PIP) hydrogel implants in a group of 64 patients and to assess the incidence of rupture, compared to other clinical trials. In this double-center study, we retrospectively reviewed the data sets of 64 consecutive patients (mean age, 43±9 years, age range, 27-65 years), who underwent breast MRI examinations, between January 2008 and October 2013, with suspected implant rupture on the basis of clinical assessment or after conventional imaging examination (either mammography or ultrasound). All patients had undergone breast operation with bilateral textured cohesive gel PIP implant insertion for aesthetic reasons. The mean time after operation was 8 years (range, 6-14 years). No patients reported history of direct trauma to their implants. At the time of clinical examination, 41 patients were asymptomatic, 16 complained of breast tenderness and 7 had clinical evidence of rupture. Normal findings were observed in 15 patients. In 26 patients there were signs of mild collapse, with associated not significant peri-capsular fluid collections and no evidence of implant rupture; in 23 patients there was suggestion of implant rupture, according to breast MRI leading to an indication for surgery. In particular, 14 patients showed intra-capsular rupture, with associated evidence of the linguine sign in all cases; the keyhole sign and the droplet signs were observed in 6 cases. In 9 patients there was evidence of extra-capsular rupture, with presence of axillary collections (siliconomas) in 7 cases and peri-prosthetic and mediastinal cavity siliconomas, in 5 cases. The results of this double center retrospective study, confirm the higher incidence (36%) of prosthesis rupture observed with the PIP implants, compared to other breast implants.

  11. Speech Understanding in Complex Listening Environments by Listeners Fit with Cochlear Implants

    ERIC Educational Resources Information Center

    Dorman, Michael F.; Gifford, Rene H.

    2017-01-01

    Purpose: The aim of this article is to summarize recent published and unpublished research from our 2 laboratories on improving speech understanding in complex listening environments by listeners fit with cochlear implants (CIs). Method: CI listeners were tested in 2 listening environments. One was a simulation of a restaurant with multiple,…

  12. Validation of the Common Objects Token (COT) Test for Children with Cochlear Implants

    ERIC Educational Resources Information Center

    Anderson, Ilona; Martin, Jane; Costa, Anne; Jamieson, Lyn; Bailey, Elspeth; Plant, Geoff; Pitterl, Markus

    2005-01-01

    Changes in selection criteria have meant that children are being provided with cochlear implants (CI) at increasingly younger ages. However, there is a paucity of measures that are appropriate for testing complex listening skills--most tests are too cognitively complex for such young children. The Common Objects Token (COT) Test was developed as a…

  13. Impurity-defect complexes in non-implanted aluminum

    NASA Astrophysics Data System (ADS)

    Pedersen, F. T.; Grann, H.; Weyer, G.

    1986-02-01

    The formation of impurity-defect complexes in ion-implanted aluminum has been studied in the temperature interval 100 400K. Radioactive119In isotopes have been implanted. Mössbauer spectra have been measured for the 24 keV γ-radiation emitted after the decay to119Sn. The spectra could be analysed satisfactorily with two lines, one of which is known to be due to substitutional Sn. A second line, which has a higher isomer shift and lower Debye temperature, is tentatively assigned to vacancy-associated Sn, formed by trapping of thermally mobile (multi-)vacancies. Comparison to similar DPAC experiments suggests that cubic Sn-V4 complexes are formed. Some indication (˜15%) for an athermal formation of impurity defects below 175K is obtained.

  14. Assessment of Myeloperoxidase and Nitric Levels around Dental Implants and Natural Teeth as a Marker of Inflammation: A Comparative Study.

    PubMed

    Kulkarni, Gayithri H; Jadhav, Prashant; Kulkarni, Kiran; Shinde, Sachin V; Patil, Yojana B; Kumar, Manish

    2016-11-01

    Dental implants form the mainstay of dental treatment involving rehabilitation of missing teeth. One of the major concerns for the clinicians doing dental implants is the postsurgical failure of dental implants. Success of dental implants is dependent upon the skills of the surgeon and the amount and quality of the bone remaining at the edentulous area where dental implant has to be placed. Myeloperoxidase (MPO) and nitrites are few of the enzymes and molecules which are said to be altered in inflammation. However, their exact role in the inflammatory processes around natural tooth and dental implant is still unclear. Hence we comparatively evaluated the levels of MPO and nitrites in the areas around the dental implants and natural teeth. The present study comprises 42 patients who underwent prosthetic rehabilitation by dental implants from 2011 to 2014. Depth of probing value (DP), score of plaque index (SPI), gingival index (GI), and index of gingival bleeding time (GBT) were evaluated for the assessment of the periimplant soft tissue changes. Assessment of inflammation around the dental implant surface and around natural tooth was done based on the readings of these parameters. For the measurement of the MPO levels, spectrophotometric MPO assay was used. All the results were analyzed by Statistical Package for the Social Sciences (SPSS) software. The mean plaque index values were 1.56 and 0.97 in periodontitis cases of natural teeth and inflamed cases of dental implants respectively. While comparing mean plaque index, mean probing depth, and mean gingival bleeding index in between the two groups, significant difference was obtained. Mean MPO concentration in periodontitis and gingivitis cases in natural teeth were 0.683 and 0.875 U/μL, while in inflamed dental implant cases, the mean value was 0.622 U/μL. While comparing the total MPO levels, total nitrite levels, and total nitrite concentration in between two study groups, significant difference was obtained. On comparing the healthy and periodontitis cases in natural teeth, significant difference was obtained. In the inflammatory processes occurring around dental implant and natural teeth, MPO and NO make some amount of significant contribution. The present study enforces on the role of MPO and nitrite as diagnostic and prognostic marker.

  15. [Polyethylene disease].

    PubMed

    Sosna, A; Radonský, T; Pokorný, D; Veigl, D; Horák, Z; Jahoda, D

    2003-01-01

    The experience obtained during revision surgery and findings of polyethylene granulomas in surrounding tissues of replacement as well as marked differences in the viability of implants resulted in the study of polyethylene disease and its basic mechanisms producing the development of osteoaggressive granulomas. We investigated the morphology of particles and their number in tissues surrounding the implant. The aim of our study was to develop a method for the detection of polyethylene particles in tissues, to identify different types of wear and to assess factors that may influence the viability of joint arthroplasty in general. Every revizion of joint arthroplasty performed during the last five years was evaluated in terms of the presence of polyethylene granules and the viability state of articular polyethylene inserts. A total of 55 samples were taken from tissues around loosened endoprostheses. The location of each sample was exactly determined. A technique was developed to identify wear particles and to visualize them after all organic structures of a polyethylene granuloma were dissolved with nitrogenic acid. The viability of articular polyethylene implants showed extreme differences in relation to different periods of manufacture and probably also to different methods of sterilization. Articular inserts sterilized with formaldehyde (the method used at the beginning of arthroplasty in our country) showed the highest viability and the lowest wear. The polyethylene particles present in tissues surrounding the implant were characterized in terms of morphology and size. The comparison of literature data and our results has revealed that there are many unknown facts about the quality and structure of polyethylene. The method of sterilization also appears to play a role. Because the issue is complex, we were not able to identify all factors leading, in some cases, to an early and unexpected failure of the implant and we consider further investigation to be necessary. Polyethylene disease is an important factor limiting the viability of joint arthroplasty. It results from a complex interaction of polyethylene particles arising by wear with surrounding tissues. The particles, less than 0.5 micron in size, are phagocytized by macrophages and, by complex mechanism of expression of inflammation mediators, they result in the inhibition of osteogenesis and activation of osteoclastic processes. The previous methods of sterilization with formaldehyde vapors apparently reduced wear influenced the resistance of polyethylene to wear to a lesser degree. A method was developed to detect these particles and to characterize their morphology in the tissues of a polyethylene granuloma.

  16. Reconstruction of the Upper Cervical Spine Using a Personalized 3D-Printed Vertebral Body in an Adolescent With Ewing Sarcoma.

    PubMed

    Xu, Nanfang; Wei, Feng; Liu, Xiaoguang; Jiang, Liang; Cai, Hong; Li, Zihe; Yu, Miao; Wu, Fengliang; Liu, Zhongjun

    2016-01-01

    Case report. To describe a three-dimensional (3D) printed axial vertebral body used in upper cervical spine reconstruction after a C2 Ewing sarcoma resection in an adolescent boy. Ewing sarcoma is a malignant musculoskeletal neoplasm with a peak incidence in adolescents. Cervical spine as the primary site of the tumor has been related to a worse prognosis. Tumor resection is particularly challenging in the atlantoaxial region due to complexity of the anatomy, necessity for extensive resection according to oncological principles, and a lack of specialized implants for reconstruction. 3D printing refers to a process where 3D objects are created through successive layering of material under computer control. Although this technology potentially enables accurate fabrication of patient-specific orthopedic implants, literature on its utilization in this regard is rare. A 12-year-old boy with a C2 Ewing sarcoma underwent a staged spondylectomy. Wide resection of the posterior elements was first performed. Two weeks later, a high anterior retropharyngeal approach was taken to remove the remains of the C2 vertebra. A customized artificial vertebral body fabricated according to a computer model using titanium alloy powder was inserted to replace the defect between C1 and C3. The microstructure of the implant was optimized for better biomechanical stability and enhanced bone healing. Patient had an uneventful recovery and began to ambulate on postoperative day 7. Adjuvant treatment commenced 3 weeks after the surgery. He was tumor-free at the 1-year follow-up. Computed tomography studies revealed evidence of implant osseointegration and no subsidence or displacement of the construct. This is a case example on the concept of personalized precision medicine in a surgical setting and demonstrates how 3D-printed, patient-specific implants may bring individualized solutions to rare problems wherein restoration of the specific anatomy of each patient is a key prognostic factor.

  17. A residual granuloma in association with a dental implant.

    PubMed

    McCracken, Michael S; Chavali, Ramakiran V; Al-Naief, Nasser Said; Eleazer, Paul D

    2012-04-01

    At times, dental implants are placed into sites with a history of periapical pathology. Sometimes the infection is active, and other times the tooth may have been extracted years before implant placement. In either case, the possibility exists for long-term residual cysts or infections that can negatively impact the prognosis of the implant. In this case report, an implant is placed into a healed mandibular ridge several months after extraction of the tooth. A radiolucency was noted on routine radiographic examination 2 years later. Surgical inspection and histology revealed a periapical granuloma with acute and chronic inflammatory cells. After surgical curettage of the site, the patient healed without complication. Implants may develop apical pathology as a result of a preexisting long-term residual infection.

  18. Women with silicone breast implants and autoimmune inflammatory syndrome induced by adjuvants: description of three patients and a critical review of the literature.

    PubMed

    Pavlov-Dolijanovic, Slavica; Vujasinovic Stupar, Nada

    2017-08-01

    Silicone has been widely used in the manufacture of medical implants. It is well tolerated in most cases. However, in this paper we report the cases of three women who developed autoimmune/inflammatory syndrome induced by adjuvants (ASIA syndrome), namely with silicone breast implants. The symptoms in these cases include arthralgia, arthritis, myalgia, sleep disturbances, the appearance of autoantibodies, miscarriage, Raynaud's phenomenon, and involvement of autoimmune diseases (scleroderma and undifferentiated connective tissue diseases). In one patient, breast implants were removed, but no improvement was seen after the removal. The remaining two patients received the updated information about their condition, and they decided not to remove the implants. In conclusion, earlier reports that silicone is biologically relatively inert have recently been challenged with the description of ASIA syndrome.

  19. Long-term amnioinfusion through a subcutaneously implanted amniotic fluid replacement port system for treatment of PPROM in humans.

    PubMed

    Tchirikov, Michael; Steetskamp, Joscha; Hohmann, Manfred; Koelbl, Heinz

    2010-09-01

    To introduce a novel method for the treatment of PPROM (preterm premature rupture of membranes) using continuous amnioinfusion via a subcutaneously implanted port system. After development and testing since 2001 in a fetal sheep model, the port system has been successfully implanted in two humans with PPROM. In the first case, the subcutaneous port system was implanted during the 23rd week of gestation in a 39-year-old 5th-gravida with PPROM since the 18th week of gestation; in the second case, the port system was implanted during the 24th week of gestation in a 27-year-old 3rd gravida with PPROM since the 21st week of gestation. After port implantation, 100ml/h saline solution was infused intermittently into the amniotic cavity. The whole course of treatment was supported by tocolysis. In the cases presented, gestation was terminated by cesarean section, in one case in the 29th week of gestation, and in the other case in the 30th week. The newborns showed no signs of lung hypoplasia and were successfully extubated on the 1st or 2nd day after delivery. Six months later the children did not exhibit any deviation from the normal development. Long-term amnioinfusion via a subcutaneously implanted port system could be used in humans with PPROM for prolongation of pregnancy and to avoid lung hypoplasia. Prospective randomized studies are ongoing. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  20. Cochlear implantation in Waardenburg syndrome: The Indian scenario.

    PubMed

    Deka, Ramesh Chandra; Sikka, Kapil; Chaturvedy, Gaurav; Singh, Chirom Amit; Venkat Karthikeyan, C; Kumar, Rakesh; Agarwal, Shivani

    2010-10-01

    Children with Waardenburg syndrome (WS) exhibiting normal inner ear anatomy, like those included in our cohort, derive significant benefit from cochlear implantation and results are comparable to those reported for the general population of implanted children. The patient population of WS accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with WS who have undergone cochlear implantation. On retrospective chart review, there were four cases with WS who underwent cochlear implantation. These cases were assessed for age at implantation, clinical and radiological features, operative and perioperative course, and performance outcomes. Auditory perception and speech production ability were evaluated using categories of auditory performance (CAP), meaningful auditory integration scales (MAIS), and speech intelligibility rating (SIR) during the follow-up period. In this group of children with WS, with a minimum follow-up of 12 months, the CAP score ranged from 3 to 5, MAIS from 25 to 30, and SIR was 3. These scores are comparable with those of other cochlear implantees.

  1. Vertical fixation with fibrin glue-assisted secondary posterior chamber intraocular lens implantation in a case of surgical aphakia

    PubMed Central

    Ladi, Jeevan S; Shah, Nitant A

    2013-01-01

    We report the first case of vertical fixation by fibrin glue-assisted secondary posterior chamber intraocular lens implantation in a case of surgical aphakia. Advantages of vertical fixation are discussed. PMID:23514650

  2. Mandibular molar uprighting using mini-implants: different approaches for different clinical cases--two case reports.

    PubMed

    Derton, Nicola; Perini, Alessandro; Mutinelli, Sabrina; Gracco, Antonio

    2012-01-01

    To detail two different clinical protocols and case studies using mini-implant anchorage developed to respond to certain clinical conditions. Two clinical protocols are described to upright mesially tilted mandibular molars. In the first protocol, a single mini-implant is inserted distally to the molar to be uprighted, and an elastic traction chain is applied to the tooth. In the second clinical approach, two mini-implants are inserted mesially. A screw-suspended TMA sectional archwire is applied (Derton-Perini technique). Two cases, descriptive of the two different treatment protocols, are described. In the first case, the mandibular right second premolar was missing and the adjacent first molar needed to be uprighted. A single screw was inserted distally to the first molar, and an elastic chain was applied. In the second case, the mandibular left second molar was missing and the third molar needed to be uprighted. Two mini-implants were inserted mesially and a fully screw-supported sectional archwire was used to upright and bodily mesialize the third molar. Both uprighting approaches uprighted the molar axis without loss of anchorage. The two approaches to mandibular molar uprighting, developed as rational responses to different clinical cases, were both found to be effective.

  3. A simple procedure for retrieval of a cement-retained implant-supported crown: a case report.

    PubMed

    Buzayan, Muaiyed Mahmoud; Mahmood, Wan Adida; Yunus, Norsiah Binti

    2014-02-01

    Retrieval of cement-retained implant prostheses can be more demanding than retrieval of screw-retained prostheses. This case report describes a simple and predictable procedure to locate the abutment screw access openings of cementretained implant-supported crowns in cases of fractured ceramic veneer. A conventional periapical radiography image was captured using a digital camera, transferred to a computer, and manipulated using Microsoft Word document software to estimate the location of the abutment screw access.

  4. [Technical feasibility of the implantation of a monorail stent system into the renal arteries without pre-dilatation].

    PubMed

    Neumann, C; Gschwendtner, M; Karnel, F; Mair, J; Dorffner, G; Dorffner, R

    2005-01-01

    To evaluate the technical feasibility of the implantation of the monorail RX Herculink system into the renal arteries without pre-dilatation. Forty-two patients (mean age 71 years) from four centers with a total of 44 renal artery stenoses underwent implantation of the RX Herculink stent. The mean grade of the stenosis was 83.8 %, the mean length 7.5 mm. The stenoses were ostial in 38 cases and in immediate proximity to the ostium in 6 cases. The mean follow-up-period was 57 weeks (24 - 176 weeks). In 42 cases, the implantation was successful without pre-dilatation. In 2 cases, pre-dilatation was carried out. In none of the cases, detachment of the stent from the balloon was observed. In one stenosis with a length of 17 mm, implantation of two stents was performed. In 9 cases, post-dilatation with a larger balloon or higher balloon pressure was necessary. Residual stenoses exceeding 30 % were not observed. Two patients developed local bleeding at the puncture site. During the follow-up, restenoses were observed in 5 stents after 26 to 126 weeks, which necessitated a second intervention in 3 cases (PTA in 2 cases, re-stenting in 1 case). The primary patency rate after 6 and 12 months was 0.92 +/- 0.056 according to Kaplan-Meier, the secondary patency rate after 6 and 12 months was 1.0 +/- 0.0. Implantation of the RX Herculink stent system into the renal arteries without pre-dilatation is technically feasible and safe. Even without pre-dilatation, the stent-system can be advanced through the stenosis without detachment. The complication rate is low. Our clinical results are comparable to previous studies.

  5. Electroencephalographic evoked pain response is suppressed by spinal cord stimulation in complex regional pain syndrome: a case report.

    PubMed

    Hylands-White, Nicholas; Duarte, Rui V; Beeson, Paul; Mayhew, Stephen D; Raphael, Jon H

    2016-12-01

    Pain is a subjective response that limits assessment. The purpose of this case report was to explore how the objectivity of the electroencephalographic response to thermal stimuli would be affected by concurrent spinal cord stimulation. A patient had been implanted with a spinal cord stimulator for the management of complex regional pain syndrome of both hands for 8 years. Following ethical approval and written informed consent we induced thermal stimuli using the Medoc PATHWAY Pain & Sensory Evaluation System on the right hand of the patient with the spinal cord stimulator switched off and with the spinal cord stimulator switched on. The patient reported a clinically significant reduction in thermal induced pain using the numerical rating scale (71.4 % reduction) with spinal cord stimulator switched on. Analysis of electroencephalogram recordings indicated the occurrence of contact heat evoked potentials (N2-P2) with spinal cord stimulator off, but not with spinal cord stimulator on. This case report suggests that thermal pain can be reduced in complex regional pain syndrome patients with the use of spinal cord stimulation and offers objective validation of the reported outcomes with this treatment.

  6. A Case of Successful Surgical Repair for Pectus Arcuatum Using Chondrosternoplasty

    PubMed Central

    Kim, Sang Yoon; Park, Samina; Kim, Eung Rae; Park, In Kyu; Kim, Young Tae; Kang, Chang Hyun

    2016-01-01

    Pectus arcuatum is a rare complex chest wall deformity. A 31-year-old female presented with a severely protruding upper sternum combined with a concave lower sternum. We planned a modified Ravitch-type operation. Through vertical mid-sternal incision, chondrectomies were performed from the second to fifth costal cartilages, saving the perichondrium. Horizontal osteotomy was performed in a wedge shape on the most protruding point, and followed by an additional partial osteotomy at the most concaved point. The harvested wedge-shape bone fragments were minced and re-implanted to the latter osteotomy site. The osteotomized sternum was fixed with multiple wirings. With chondrosternoplasty, a complex chest wall deformity can be corrected successfully. PMID:27298803

  7. A Case of Successful Surgical Repair for Pectus Arcuatum Using Chondrosternoplasty.

    PubMed

    Kim, Sang Yoon; Park, Samina; Kim, Eung Rae; Park, In Kyu; Kim, Young Tae; Kang, Chang Hyun

    2016-06-01

    Pectus arcuatum is a rare complex chest wall deformity. A 31-year-old female presented with a severely protruding upper sternum combined with a concave lower sternum. We planned a modified Ravitch-type operation. Through vertical mid-sternal incision, chondrectomies were performed from the second to fifth costal cartilages, saving the perichondrium. Horizontal osteotomy was performed in a wedge shape on the most protruding point, and followed by an additional partial osteotomy at the most concaved point. The harvested wedge-shape bone fragments were minced and re-implanted to the latter osteotomy site. The osteotomized sternum was fixed with multiple wirings. With chondrosternoplasty, a complex chest wall deformity can be corrected successfully.

  8. Cutaneous Disseminated and Extracutaneous Sporotrichosis: Current Status of a Complex Disease

    PubMed Central

    Bonifaz, Alexandro; Tirado-Sánchez, Andrés

    2017-01-01

    Sporotrichosis is an implantation or inoculation mycosis caused by species of Sporothrix schenckii complex; its main manifestations are limited to skin; however, cutaneous-disseminated, disseminated (visceral) and extracutaneous variants of sporotrichosis can be associated with immunosuppression, including HIV-AIDS, chronic alcoholism or more virulent strains. The most common extracutaneous form of sporotrichosis includes pulmonary, osteoarticular and meningeal. The laboratory diagnosis requires observing yeast forms and isolating the fungus; the two main causative agents are Sporothrix schenckii (ss) and Sporothrix brasiliensis. Antibody levels and species recognition by Polimerase Chain Reaction using biological samples or cultures are also useful. The treatment of choice for most cases is amphotericin B and subsequent itraconazole for maintenance therapy. PMID:29371525

  9. Cutaneous Disseminated and Extracutaneous Sporotrichosis: Current Status of a Complex Disease.

    PubMed

    Bonifaz, Alexandro; Tirado-Sánchez, Andrés

    2017-02-10

    Sporotrichosis is an implantation or inoculation mycosis caused by species of Sporothrix schenckii complex; its main manifestations are limited to skin; however, cutaneous-disseminated, disseminated (visceral) and extracutaneous variants of sporotrichosis can be associated with immunosuppression, including HIV-AIDS, chronic alcoholism or more virulent strains. The most common extracutaneous form of sporotrichosis includes pulmonary, osteoarticular and meningeal. The laboratory diagnosis requires observing yeast forms and isolating the fungus; the two main causative agents are Sporothrix schenckii ( ss ) and Sporothrix brasiliensis . Antibody levels and species recognition by Polimerase Chain Reaction using biological samples or cultures are also useful. The treatment of choice for most cases is amphotericin B and subsequent itraconazole for maintenance therapy.

  10. Implantation of VVI pacemaker in a patient with dextrocardia, persistent left superior vena cava, and sick sinus syndrome

    PubMed Central

    Guo, Gongliang; Yang, Lili; Wu, Jinyi; Sun, Liqun

    2017-01-01

    Abstract Background: Dextrocardia, or right-lying heart, is an uncommon congenital heart disease in which the apex of the heart is located on the right side of chest. Persistent left superior vena cava (PLSVA) is a rare venous anomaly that is often associated with the abnormalities of cardiac transduction system. A case with combination of dextrocardia, persistent left superior vena cava, and sick sinus syndrome has not been reported. Methods: We used different techniques including cardiac color Doppler echocardiography, 24-hour Holter monitoring, and abdominal ultrasound to make a diagnosis and treated the patient by implanting a VVI pacemaker. Results: A 50-year-old woman was admitted with a syncope. Angiography of the right atrium and superior vena cava, echocardiography, electrocardiography, and abdominal ultrasound revealed the presence of the combination of mirror image dextrocardia, PLSVA, and sick sinus syndrome. The complex structural anomalies presented great technical challenges for interventional treatments. After thorough examination and understanding of the structural anatomy and anomalies of the superior and inferior vena cava and cardiac chambers, we successfully treated this patient by implanting a VVI pacemaker. Conclusion: Physicians must be aware of the complexity of the morphological and anatomical structures of dextrocardia accompanying PLSVC. Given that the diagnosis of situs inversus was performed at a relatively advanced age, it is therefore important to make such a correct diagnosis followed by appropriate therapeutic intervention. PMID:28151908

  11. Artificial urinary sphincter implantation: an important component of complex surgery for urinary tract reconstruction in patients with refractory urinary incontinence.

    PubMed

    Zhang, Fan; Liao, Limin

    2018-01-08

    We review our outcomes and experience of artificial urinary sphincter implantation for patients with refractory urinary incontinence from different causes. Between April 2002 and May 2017, a total of 32 patients (median age, 40.8 years) with urinary incontinence had undergone artificial urinary sphincter placement during urinary tract reconstruction. Eighteen patients (56.3%) were urethral injuries associated urinary incontinence, 9 (28.1%) had neurogenic urinary incontinence and 5 (15.6%) were post-prostatectomy incontinence. Necessary surgeries were conducted before artificial urinary sphincter placement as staged procedures, including urethral strictures incision, sphincterotomy, and augmentation cystoplasty. The mean follow-up time was 39 months. At the latest visit, 25 patients (78.1%) maintained the original artificial urinary sphincter. Four patients (12.5%) had artificial urinary sphincter revisions. Explantations were performed in three patients. Twenty-four patients were socially continent, leading to the overall success rate as 75%. The complication rate was 28.1%; including infections (n = 4), erosions (n = 4), and mechanical failure (n = 1). The impact of urinary incontinence on the quality of life measured by the visual analogue scale dropped from 7.0 ± 1.2 to 2.2 ± 1.5 (P <0.001). The primary sources for artificial urinary sphincter implantation in our center are unique, and the procedure is an effective treatment as a part of urinary tract reconstruction in complicated urinary incontinence cases with complex etiology.

  12. Breast Implants and the Risk of Anaplastic Large-Cell Lymphoma in the Breast.

    PubMed

    de Boer, Mintsje; van Leeuwen, Flora E; Hauptmann, Michael; Overbeek, Lucy I H; de Boer, Jan Paul; Hijmering, Nathalie J; Sernee, Arthur; Klazen, Caroline A H; Lobbes, Marc B I; van der Hulst, René R W J; Rakhorst, Hinne A; de Jong, Daphne

    2018-03-01

    Breast implants are among the most commonly used medical devices. Since 2008, the number of women with breast implants diagnosed with anaplastic large-cell lymphoma in the breast (breast-ALCL) has increased, and several reports have suggested an association between breast implants and risk of breast-ALCL. However, relative and absolute risks of breast-ALCL in women with implants are still unknown, precluding evidence-based counseling about implants. To determine relative and absolute risks of breast-ALCL in women with breast implants. Through the population-based nationwide Dutch pathology registry we identified all patients diagnosed with primary non-Hodgkin lymphoma in the breast between 1990 and 2016 and retrieved clinical data, including breast implant status, from the treating physicians. We estimated the odds ratio (OR) of ALCL associated with breast implants in a case-control design, comparing implant prevalence between women with breast-ALCL and women with other types of breast lymphoma. Cumulative risk of breast-ALCL was derived from the age-specific prevalence of breast implants in Dutch women, estimated from an examination of 3000 chest x-rays and time trends from implant sales. Relative and absolute risks of breast-ALCL in women with breast implants. Among 43 patients with breast-ALCL (median age, 59 years), 32 had ipsilateral breast implants, compared with 1 among 146 women with other primary breast lymphomas (OR, 421.8; 95% CI, 52.6-3385.2). Implants among breast-ALCL cases were more often macrotextured (23 macrotextured of 28 total implants of known type, 82%) than expected (49 193 sold macrotextured implants of total sold 109 449 between 2010 and 2015, 45%) based on sales data (P < .001). The estimated prevalence of breast implants in women aged 20 to 70 years was 3.3%. Cumulative risks of breast-ALCL in women with implants were 29 per million at 50 years and 82 per million at 70 years. The number of women with implants needed to cause 1 breast-ALCL case before age 75 years was 6920. Breast implants are associated with increased risk of breast-ALCL, but the absolute risk remains small. Our results emphasize the need for increased awareness among the public, medical professionals, and regulatory bodies, promotion of alternative cosmetic procedures, and alertness to signs and symptoms of breast-ALCL in women with implants.

  13. Slow positron beam study of hydrogen ion implanted ZnO thin films

    NASA Astrophysics Data System (ADS)

    Hu, Yi; Xue, Xudong; Wu, Yichu

    2014-08-01

    The effects of hydrogen related defect on the microstructure and optical property of ZnO thin films were investigated by slow positron beam, in combination with x-ray diffraction, infrared and photoluminescence spectroscopy. The defects were introduced by 90 keV proton irradiation with doses of 1×1015 and 1×1016 ions cm-2. Zn vacancy and OH bonding (VZn+OH) defect complex were identified in hydrogen implanted ZnO film by positron annihilation and infrared spectroscopy. The formation of these complexes led to lattice disorder in hydrogen implanted ZnO film and suppressed the luminescence process.

  14. Gliomatosis peritonei. Report of two cases and review of literature.

    PubMed

    Truong, L D; Jurco, S; McGavran, M H

    1982-07-01

    Gliomatosis peritonei, a rare complication of solid ovarian teratomas, is a miliary, mature glial implantation on the peritoneum or omentum. Two new cases are reported and 30 previously reported cases are reviewed. Gliomatosis peritonei is thought to be benign in almost all cases and thus deserves no treatment except for confirmatory biopsy. It must be differentiated from teratomatous implants because the latter may imply poor prognosis and require aggressive therapy. The prognostic value of serum alpha-fetoprotein levels in patients with immature ovarian teratoma is not conclusive. The presence of glial fibrillary acidic protein confirms the glial nature of the implants.

  15. Breast Implant-Associated Anaplastic Large Cell Lymphoma in Australia and New Zealand: High-Surface-Area Textured Implants Are Associated with Increased Risk.

    PubMed

    Loch-Wilkinson, Anna; Beath, Kenneth J; Knight, Robert John William; Wessels, William Louis Fick; Magnusson, Mark; Papadopoulos, Tim; Connell, Tony; Lofts, Julian; Locke, Michelle; Hopper, Ingrid; Cooter, Rodney; Vickery, Karen; Joshi, Preeti Avinash; Prince, H Miles; Deva, Anand K

    2017-10-01

    The association between breast implants and breast implant-associated anaplastic large cell lymphoma (ALCL) has been confirmed. Implant-related risk has been difficult to estimate to date due to incomplete datasets. All cases in Australia and New Zealand were identified and analyzed. Textured implants reported in this group were subjected to surface area analysis. Sales data from three leading breast implant manufacturers (i.e., Mentor, Allergan, and Silimed) dating back to 1999 were secured to estimate implant-specific risk. Fifty-five cases of breast implant-associated ALCL were diagnosed in Australia and New Zealand between 2007 and 2016. The mean age of patients was 47.1 years and the mean time of implant exposure was 7.46 years. There were four deaths in the series related to mass and/or metastatic presentation. All patients were exposed to textured implants. Surface area analysis confirmed that higher surface area was associated with 64 of the 75 implants used (85.3 percent). Biocell salt loss textured (Allergan, Inamed, and McGhan) implants accounted for 58.7 percent of the implants used in this series. Comparative analysis showed the risk of developing breast implant-associated ALCL to be 14.11 times higher with Biocell textured implants and 10.84 higher with polyurethane (Silimed) textured implants compared with Siltex textured implants. This study has calculated implant-specific risk of breast implant-associated ALCL. Higher-surface-area textured implants have been shown to significantly increase the risk of breast implant-associated ALCL in Australia and New Zealand. The authors present a unifying hypothesis to explain these observations.

  16. Training needs for general dentistry residents to place and restore two-implant-retained mandibular overdentures.

    PubMed

    Malmstrom, Hans; Xiao, Jin; Romanos, Georgios E; Ren, Yan-Fang

    2015-01-01

    Implant therapy is rapidly becoming a standard of care for replacing missing dentition. Predoctoral dental curricula include some training in the implant restorative phase but offer limited exposure to the surgical phase, so it is important for postdoctoral general dentistry residency programs to provide competency training in all phases of implant therapy. The aim of this study was to determine the training needed for general dentistry residents to achieve competence in this area, specifically by defining the number of clinical experiences necessary in both the surgical and prosthetic phases of implant-retained mandibular overdenture construction (IRMOD). Fifteen Advanced Education in General Dentistry (AEGD) residents at one academic dental institution placed two implants in a total of 50 patients with edentulous mandibles and subsequently restored them with IRMOD. The supervising faculty member and the residents evaluated the competency level on a five-point scale after each implant placement and prosthetic case completion. According to the faculty evaluations, the residents achieved surgical competence after placing two implants in four to six cases and prosthetic management competence after restoring two to four cases of IRMOD. All 50 patients were satisfied with the treatment outcomes of IRMOD. This study concluded that general dentistry residents could potentially achieve competence in both the surgical and prosthetic phases of implant therapy while enrolled in an AEGD program.

  17. Micro finite element analysis of dental implants under different loading conditions.

    PubMed

    Marcián, Petr; Wolff, Jan; Horáčková, Ladislava; Kaiser, Jozef; Zikmund, Tomáš; Borák, Libor

    2018-05-01

    Osseointegration is paramount for the longevity of dental implants and is significantly influenced by biomechanical stimuli. The aim of the present study was to assess the micro-strain and displacement induced by loaded dental implants at different stages of osseointegration using finite element analysis (FEA). Computational models of two mandible segments with different trabecular densities were constructed using microCT data. Three different implant loading directions and two osseointegration stages were considered in the stress-strain analysis of the bone-implant assembly. The bony segments were analyzed using two approaches. The first approach was based on Mechanostat strain intervals and the second approach was based on tensile/compression yield strains. The results of this study revealed that bone surrounding dental implants is critically strained in cases when only a partial osseointegration is present and when an implant is loaded by buccolingual forces. In such cases, implants also encounter high stresses. Displacements of partially-osseointegrated implant are significantly larger than those of fully-osseointegrated implants. It can be concluded that the partial osseointegration is a potential risk in terms of implant longevity. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Micro CT and human histological analysis of a peri-implant osseous defect grafted with porous titanium granules: a case report.

    PubMed

    Wohlfahrt, Johan Caspar; Aass, Anne Merete; Ronold, Hans Jacob; Lyngstadaas, Stale Petter

    2011-01-01

    Treatment of peri-implant osseous defects represents a significant challenge for clinicians, and the need to evolve within predictable surgical procedures is important. This case report describes the surgical treatment and grafting with porous titanium granules (PTG) of one patient with a peri-implant osseous defect. The suggested thrombogenic properties of titanium are intriguing from the perspective of osseous reconstructive surgery. In an ongoing randomized clinical trial using PTG for treatment of peri-implant osseous defects, one patient with one test implant was excluded and scheduled for implant removal. The surgical therapy included open flap debridement with surface decontamination with 24% EDTA gel, grafting with PTG, and resubmersion of the implant. After 12 months of healing, the implant with surrounding tissues was excised en bloc and micro CT and histological analyses were performed. Analyses showed PTG in close contact with new bone and with bone growing both into the porosities of the graft material and onto the adjacent implant surface. Element analysis demonstrated calcium and phosphorus in the new tissue embedding the PTG and the implant. Int J Oral Maxillofac Implants 2011;26:e9-e14.

  19. Lateral approach for maxillary sinus membrane elevation without bone materials in maxillary mucous retention cyst with immediate or delayed implant rehabilitation: case reports.

    PubMed

    Han, Ji-Deuk; Cho, Seong-Ho; Jang, Kuk-Won; Kim, Seong-Gwang; Kim, Jung-Han; Kim, Bok-Joo; Kim, Chul-Hun

    2017-08-01

    This case series study demonstrates the possibility of successful implant rehabilitation without bone augmentation in the atrophic posterior maxilla with cystic lesion in the sinus. Sinus lift without bone graft using the lateral approach was performed. In one patient, the cyst was aspirated and simultaneous implantation under local anesthesia was performed, whereas the other cyst was removed under general anesthesia, and the sinus membrane was elevated in a second process, followed by implantation. In both cases, tapered 11.5-mm-long implants were utilized. With all of the implants, good stability and appropriate bone height were achieved. The mean bone level gain was 5.73 mm; adequate bone augmentation around the implants was shown, the sinus floor was moved apically, and the cyst was no longer radiologically detected. Completion of all of the treatments required an average of 12.5 months. The present study showed that sufficient bone formation and stable implantation in a maxilla of insufficient bone volume are possible through sinus lift without bone materials. The results serve to demonstrate, moreover, that surgical treatment of mucous retention cyst can facilitate rehabilitation. These techniques can reduce the risk of complications related to bone grafts, save money, and successfully treat antral cyst.

  20. Lateral approach for maxillary sinus membrane elevation without bone materials in maxillary mucous retention cyst with immediate or delayed implant rehabilitation: case reports

    PubMed Central

    2017-01-01

    This case series study demonstrates the possibility of successful implant rehabilitation without bone augmentation in the atrophic posterior maxilla with cystic lesion in the sinus. Sinus lift without bone graft using the lateral approach was performed. In one patient, the cyst was aspirated and simultaneous implantation under local anesthesia was performed, whereas the other cyst was removed under general anesthesia, and the sinus membrane was elevated in a second process, followed by implantation. In both cases, tapered 11.5-mm-long implants were utilized. With all of the implants, good stability and appropriate bone height were achieved. The mean bone level gain was 5.73 mm; adequate bone augmentation around the implants was shown, the sinus floor was moved apically, and the cyst was no longer radiologically detected. Completion of all of the treatments required an average of 12.5 months. The present study showed that sufficient bone formation and stable implantation in a maxilla of insufficient bone volume are possible through sinus lift without bone materials. The results serve to demonstrate, moreover, that surgical treatment of mucous retention cyst can facilitate rehabilitation. These techniques can reduce the risk of complications related to bone grafts, save money, and successfully treat antral cyst. PMID:28875144

  1. The incidence and causative organisms of infection in elective shoulder surgery.

    PubMed

    Mayne, Alistair I W; Bidwai, Amit S; Clifford, Rachael; Smith, Matthew G; Guisasola, Inigo; Brownson, Peter

    2018-07-01

    Deep infection remains a serious complication of orthopaedic surgery. Knowledge of infection rates and causative organisms is important to guide infection control measures. The aim of the present study was to determine infection rates and causative organisms in elective shoulder surgery. Cases complicated by infection were identified and prospectively recorded over a 2-year period. All patients undergoing elective shoulder surgery in the concurrent period at a single Specialist Upper Limb Unit in the UK were identified from the hospital electronic database. In total, 1574 elective shoulder cases were performed: 1359 arthroscopic (540 with implant insertion) and 215 open (197 with implant insertion). The overall infection rate in open surgery of 2.5% was significantly higher than arthroscopic implant cases at 0.7% ( p  < 0.005). The overall infection rate in implant arthroscopic surgery was significantly higher at 0.7% compared to 0% in non-implant related surgery. ( p  < 0.05). Patients undergoing open shoulder surgery have a significantly higher risk of infection compared to arthroscopic shoulder surgery. Arthroscopic surgery with implant insertion has a statistically significantly higher risk of developing deep infection compared to procedures with no implant insertion. We recommend prophylactic antibiotics in open shoulder surgery and arthroscopic shoulder surgery with implant insertion.

  2. A retrospective evaluation of 128 socket-shield cases in the esthetic zone and posterior sites: Partial extraction therapy with up to 4 years follow-up.

    PubMed

    Gluckman, Howard; Salama, Maurice; Du Toit, Jonathan

    2018-04-01

    Tooth loss results in an inevitable alveolar ridge reduction. This has established a cautionary approach to extract, wait, augment, and insert the implant, in lieu of immediate placement. However, saving the tooth or part of it whenever possible is more conservative and supports the vital periodontal tissue buccofacial to an implant. The purpose of this cases series was to report on implant survival using this technique in a large cohort of patients at mid-term follow-up. A private practice patient database was searched for all patients having received socket-shield treatment in conjunction with immediate implant placement. Of the results returned, 128 met the inclusion criteria of ≥12 months from date of restoration, or failing prior to definitive restoration. These patients were recalled for evaluation of the restored implants up to 4 years post-treatment. Seventy immediate implants with socket-shields were placed in female patients and 58 in males, age range 24-71 (mean 39 years). The distribution of sites treated were: maxillary incisors (64%), premolars (22%), canines (14%); maxilla (89.9%), mandible (10.1%). 123/128 implants osseointegrated and survived 1-4 years following restoration (survival rate 96.1%). A combined complication rate of 25/128 implants occurred (19.5%). Five implants failed to osseointegrate and were removed. The remaining 20 complications were all managed or observed without management, with implants surviving at mid-term follow-up. Notwithstanding technique sensitivity and the need for randomized control studies, this case series demonstrates that the socket-shield performs competitively when compared to implant survival rates in both conventional immediate and delayed implant placement. © 2017 Wiley Periodicals, Inc.

  3. Outcomes of Dental Implant Therapy in Patients With Down Syndrome: A Systematic Review.

    PubMed

    Najeeb, Shariq; Khurshid, Zohaib; Siddiqui, Fahad; Zohaib, Sana; Zafar, Muhammad Sohail

    2017-12-01

    Patients with Down syndrome (DS) require an earlier and more frequent tooth replacement than rest of the population. The objective of this systematic review is to critically analyze and summarize studies to ascertain the outcomes and survival of dental implants placed in jaws of DS patients. Using the key words "dental implants," "Down syndrome," and "prosthodontics," an electronic search was conducted via PubMed/MEDLINE, ISI Web of Science, Google Scholar, Embase, and Central Register of Controlled Trials (CENTRAL) databases by 2 authors, S.N. and Z.K., independently. Retrieved studies were screened against the predefined exclusion and inclusion criteria. To estimate the risk of bias, quality assessment of included studies was carried using the 'Case Reports (CARE) guidelines'. Primary search resulted in 156 studies. Eight studies met the inclusion criteria and reporting a total of 81 dental implants placed in 36 DS patients. The type of implant loading ranged from immediate to a delay of 1 year after placement of the implant. Implant diameter ranged from 3.3 to 4.5 mm, and height ranged from 8.5 to 18 mm. The follow-up ranged from 1 to 6 years. Of 81 implants placed, 21 implants (26%) were reported as failed. Patients with DS have a higher risk of implant failure. However, the reason for the failure is not very well understood. Although case reports and case series suggest that implant survival is diminished in DS patients, large-scale randomized controlled trials are required to determine the exact mechanism associated with risks of implant failure. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Long-term efficacy of biomodeled polymethyl methacrylate implants for orbitofacial defects.

    PubMed

    Groth, Michael J; Bhatnagar, Aparna; Clearihue, William J; Goldberg, Robert A; Douglas, Raymond S

    2006-01-01

    To report the long-term efficacy of custom polymethyl methacrylate implants using high-resolution computed tomographic modeling in the reconstruction of complex orbitofacial defects secondary to trauma. Nine patients with complex orbitofacial bone defects after trauma were evaluated for this retrospective, nonrandomized, noncomparative study. All the patients underwent reconstruction using custom, heat-cured polymethyl methacrylate implants. Patients were followed up postoperatively and evaluated for complications. Nine consecutive patients (5 men and 4 women) aged 28 to 63 years who underwent surgical reconstruction using prefabricated, heat-cured polymethyl methacrylate implants were included in the study. The interval between injury and presentation ranged from 1 month to 40 years. There were no significant complications, including infection, extrusion, or displacement of the implant. In all of the patients, wound healing was uneventful, with antibiotic drugs administered perioperatively. Mean follow-up was 4.3 years from the first visit (range, 6 months to 10 years). Computed tomographic biomodeled, prefabricated, heat-cured polymethyl methacrylate implants are well tolerated in the long term. Their advantages include customized design, long-term biocompatibility, and excellent aesthetic results.

  5. Scala vestibuli insertion in cochlear implantation: a valuable alternative for cases with obstructed scala tympani.

    PubMed

    Kiefer, J; Weber, A; Pfennigdorff, T; von Ilberg, C

    2000-01-01

    Insertion of a sufficient number of electrodes is important for a successful use of cochlear implants. We investigated the results of scala vestibuli insertion for cochlear implantation in cases of obstructed scala tympani. In a series of 200 cochlear implantations, scala vestibuli insertion was successfully performed in 4 cases with obstruction of the scala tympani. Etiologies included a temporal bone fracture, severe otosclerosis and malformations of the cochlea. The maximum insertion depth obtained via the scala vestibuli was 30 mm. Postoperative results were comparable to patients in whom conventional scala tympani insertion was performed. No adverse effects related to the site of insertion were observed. Scala vestibuli insertion offers a valuable alternative in cases of obstructed scala tympani that can be employed for a variety of etiologies. Copyright 2000 S. Karger AG, Basel

  6. Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature.

    PubMed

    Klein, Doron; Hadad, Eran; Wiser, Itay; Wolf, Omer; Itzhaki Shapira, Ortal; Fucks, Shir; Heller, Lior

    2018-01-01

    Silicone breast implants from the French manufacturer Poly Implants Prosthèse (PIP) were recalled from the European market after the French regulator has revealed the implants contain non-medical-grade silicone filler. In December 2011, following a large increase in reported rupture rate and a possible cancer risk, the French Ministry of Health recommended consideration of the PIP explantation, regardless of their condition. In 2012, the Israel Ministry of Health recommended to replace the implants only upon suspected implant rupture. The aims of this study were to characterize breast-augmented Israeli patients with PIP implants, compare their outcomes with those of breast-augmented patients with different implant types, and review the current PIP literature. Breast-augmented patients who underwent an elective breast implant exchange in Israel between January 2011 and January 2017 were included in the study. Data were collected from electronic and physical medical files. There were 73 breast-augmented female patients with 146 PIP breast implants included in this study. Average implant age was 6.7 ± 2.79 years. Mean implant size was 342.8 ± 52.9 mL. Fourteen women (19 implants [16%]) had a high-grade capsular contracture (Baker grade 3-4). During exchange, 28 implants were found to be ruptured (19.2%). Less than 10 years following breast augmentation, PIP implants demonstrated higher rupture rate compared with other implants. Our data are comparable to overall available rupture rate. Among patients with definitive rupture diagnosis, an elective implant removal should be recommended. In cases of undamaged implants, plastic surgeons should also seriously consider PIP implant explantation. When the patient does not desire to remove the implant, an annual physical examination and breast ultrasound are recommended, beginning a year after augmentation.

  7. Exotic encounters with dental implants: managing complications with unidentified systems.

    PubMed

    Mattheos, N; Janda, M Schittek

    2012-06-01

    As the application of dental implants increases worldwide, so is the number of technical and biological complications that general dental practitioners will be called to manage, while maintaining implant patients. In addition, the greater patient mobility encountered today combined with a growing trend of 'dental implant tourism' will very often result in situations where the dentist is requested to deal with complications in implants placed elsewhere and which sometimes might be of an 'exotic' system one cannot directly recognize. Such a situation can pose significant challenges to even experienced clinicians. The challenges are not only in the scientific field, but often include professional and ethical implications. This case report will discuss strategies for the management of implant complications in cases of unidentified implant systems. Critical factors in such situations would be the clinician's experience and special training, the correct radiographic technique, as well as access to the appropriate tools and devices. © 2012 Australian Dental Association.

  8. Accidental injections of dexamethasone intravitreal implant (Ozurdex) into the crystalline lens.

    PubMed

    Coca-Robinot, Javier; Casco-Silva, Bruno; Armadá-Maresca, Felix; García-Martínez, Jesús

    2014-01-01

    To describe the side effects and management after inadvertent injection of a dexamethasone implant (Ozurdex) into the crystalline lens. Two case reports. Two patients with macular edema due to unilateral retinal vein occlusion were scheduled for an intravitreal injection of Ozurdex. During the procedure, the implant was accidentally injected into the crystalline lens. Both patients developed cataracts during the course of several weeks and in both there was an intraocular pressure (IOP) increase, which required treatment with topical hypotensives. Macular edema improved only slightly. Cataract surgery with uneventful removal of the implant was performed 3 (case 1) and 6 months (case 2) after the injection. After inadvertent injection of Ozurdex into the crystalline lens, cataract surgery with removal of the implant should be performed as soon as possible in order to avoid IOP increase and so that the underlying condition may be treated adequately.

  9. Breast Implant-Associated Anaplastic Large Cell Lymphoma: Case Report and Review of the Literature.

    PubMed

    Berlin, Eva; Singh, Kunwar; Mills, Christopher; Shapira, Ilan; Bakst, Richard L; Chadha, Manjeet

    2018-01-01

    We are reporting the case of a 58-year-old woman with history of bilateral silicone breast implants for cosmetic augmentation. At 2-year interval from receiving the breast implants, she presented with swelling of the right breast with associated chest wall mass, effusion around the implant, and axillary lymphadenopathy. Pathology confirmed breast implant-associated anaplastic large cell lymphoma (stage III, T4N2M0, using BIA-ALCL TNM staging and stage IIAE, using Ann-Arbor staging). The patient underwent bilateral capsulectomy and right partial mastectomy with excision of the right breast mass and received adjuvant CHOP chemotherapy and radiation to the right breast and regional nodes. Since completion of multimodality therapy, the patient has sustained remission on both clinical exam and PET/CT scan. We report this case and review of the literature on this rare form of lymphoma.

  10. Breast Implant-Associated Anaplastic Large Cell Lymphoma: Case Report and Review of the Literature

    PubMed Central

    Singh, Kunwar; Mills, Christopher; Shapira, Ilan

    2018-01-01

    We are reporting the case of a 58-year-old woman with history of bilateral silicone breast implants for cosmetic augmentation. At 2-year interval from receiving the breast implants, she presented with swelling of the right breast with associated chest wall mass, effusion around the implant, and axillary lymphadenopathy. Pathology confirmed breast implant-associated anaplastic large cell lymphoma (stage III, T4N2M0, using BIA-ALCL TNM staging and stage IIAE, using Ann-Arbor staging). The patient underwent bilateral capsulectomy and right partial mastectomy with excision of the right breast mass and received adjuvant CHOP chemotherapy and radiation to the right breast and regional nodes. Since completion of multimodality therapy, the patient has sustained remission on both clinical exam and PET/CT scan. We report this case and review of the literature on this rare form of lymphoma. PMID:29607225

  11. Alveolar ridge preservation of an extraction socket using autogenous tooth bone graft material for implant site development: prospective case series

    PubMed Central

    Yun, Pil-Young; Um, In-Woong; Lee, Hyo-Jung; Yi, Yang-Jin; Bae, Ji-Hyun; Lee, Junho

    2014-01-01

    This case series evaluated the clinical efficacy of autogenous tooth bone graft material (AutoBT) in alveolar ridge preservation of an extraction socket. Thirteen patients who received extraction socket graft using AutoBT followed by delayed implant placements from Nov. 2008 to Aug. 2010 were evaluated. A total of fifteen implants were placed. The primary and secondary stability of the placed implants were an average of 58 ISQ and 77.9 ISQ, respectively. The average amount of crestal bone loss around the implant was 0.05 mm during an average of 22.5 months (from 12 to 34 months) of functional loading. Newly formed tissues were evident from the 3-month specimen. Within the limitations of this case, autogenous tooth bone graft material can be a favorable bone substitute for extraction socket graft due to its good bone remodeling and osteoconductivity. PMID:25551013

  12. Infection after pacemaker implantation: infection rates and risk factors associated with infection in a population-based cohort study of 46299 consecutive patients

    PubMed Central

    Johansen, Jens Brock; Jørgensen, Ole Dan; Møller, Mogens; Arnsbo, Per; Mortensen, Peter Thomas; Nielsen, Jens Cosedis

    2011-01-01

    Aims Infection is a serious complication of pacemaker (PM) systems. Although the rate of infection has been debated, the figures are largely unknown. We therefore studied the incidence of PM infection and its associated risk factors in the Danish population. Methods and results Since 1982, all PM implantation and removal procedures performed in Denmark have been prospectively recorded in the Danish Pacemaker Register. All patients (n = 46299) who underwent implantation between 1982 and 2007 were included. The total length of surveillance was 236 888 PM-years. The incidence of infection was calculated according to the total number of PM-years. The incidence of surgical site infection (≤365 days after PM implantation) was compared with later infection in first implant and replacement procedures. Multiple-record and multiple-event-per-subject proportional hazards analyses were used to identify the independent risk factors of PM infection. Surgical site infection occurred in 192 cases after first implantation (incidence rate 4.82/1000 PM-years), and in 133 cases after replacement (12.12/1000 PM-years). Infections occurring more than 365 days after the first implantation occurred in 153 cases (1.02/1000 PM-years), and in 118 cases after replacement (3.26/1000 PM-years). Independent factors associated with an increased risk of PM infection were a greater number of PM operations (including replacements), male sex, younger age, implantation during the earliest part of the study period, and absence of antibiotics (P< 0.001). Conclusion The overall risk of infection after PM implantation was low. A greater number of operations augmented the risk of infection. This should be taken into account when considering revisions of PM systems. PMID:21252172

  13. ALK-1-negative anaplastic large cell lymphoma associated with breast implants: a new clinical entity.

    PubMed

    Lazzeri, Davide; Agostini, Tommaso; Bocci, Guido; Giannotti, Giordano; Fanelli, Giovanni; Naccarato, Antonio Giuseppe; Danesi, Romano; Tuccori, Marco; Pantaloni, Marcello; D'Aniello, Carlo

    2011-10-01

    Concerns have been raised recently regarding the increasing number of reports of non-Hodgkin lymphoma (NHL) that developed in close proximity to silicone or saline breast implants. In particular, an increased risk of anaplastic large cell lymphoma (ALCL) in patients with breast prostheses has been proposed. We reviewed clinical and pathologic findings in 40 women who received a diagnosis of breast NHL arising in association with breast implants and of 27 patients who had a diagnosis of ALCL with breast involvement reported in the published literature. Among the 40 reported cases of prosthesis-associated breast lymphomas, 28 were anaplastic lymphoma kinase-1-negative (ALK-1(-)) ALCLs, whereas of 27 ALCLs in patients without implants found in the literature, only 10 were ALK-1(-). The finding of 28 cases of breast ALK-1(-) ALCL occurring in patients with implants compared with 10 cases in women without implants is in favor of an association between silicone breast prostheses and ALK-1(-) ALCL. Although the incidence of this type of lymphoma remains remarkably low given that breast prostheses have been widely used for decades, clinical and pathologic evidence for a causative role is becoming dramatically strong. The histologic, phenomenologic, and clinical similarities of the majority of implant-related ALK-1(-) ALCLs suggest a common mechanism, especially when compared with the counterpart of patients without implants in which very few and highly dishomogeneous cases of the same malignancy were detected. There is convincing evidence that primary implant-related ALK-1(-) ALCL represents a distinct clinicopathologic entity that has been inappropriately fitted into the category of systemic ALK-1(-) ALCL. Thus it should be recognized as a separate category and classified on its own. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Peri-Implantitis Associated with Type of Cement: A Retrospective Analysis of Different Types of Cement and Their Clinical Correlation to the Peri-Implant Tissue.

    PubMed

    Korsch, Michael; Walther, Winfried

    2015-10-01

    The cementation of fixed implant-supported dental restorations involves the risk of leaving excess cement in the mouth which can promote biofilm formation in the peri-implant sulcus. As a result, an inflammation may develop. The aim of the present study was to investigate the clinical effect of two different luting cements on the peri-implant tissue. Within the scope of a retrospective clinical follow-up study, the prosthetic structures of 22 patients with 45 implants were revised. In all cases, a methacrylate cement (Premier Implant Cement [PIC], Premier® Dental Products Company, Plymouth Meeting, PA, USA) had been used for cementation. In 16 additional patients with 28 implants, the suprastructures were retained with a zinc oxide-eugenol cement (Temp Bond [TB], Kerr Sybron Dental Specialities, Glendora, CA, USA). These patients were evaluated in the course of routine treatment. In both populations, the retention time of the suprastructures was similar (TB 3.77 years, PIC 4.07 years). In the PIC cases, 62% of all implants had excess cement. In the TB cases, excess cement was not detectable on any of the implants. Bleeding on probing was significantly more frequent on implants cemented with PIC (100% with and 94% without excess cement) than on implants cemented with TB (46%). Pocket suppuration was observed on 89% of the PIC-cemented implants with excess cement (PIC without excess cement 24%), whereas implants with TB were not affected by it at all. The peri-implant bone loss was significantly greater in the PIC patients (with excess cement 1.37 mm, without excess cement 0.41 mm) than it was in the TB patients (0.07 mm). The frequency of undetected excess cement depends essentially on the type of cement used. Cements that tend to leave more undetected excess have a higher prevalence for peri-implant inflammation and cause a more severe peri-implant bone loss. © 2014 Wiley Periodicals, Inc.

  15. Case presentation of florid cemento-osseous dysplasia with concomitant cemento-ossifying fibroma discovered during implant explantation.

    PubMed

    Gerlach, Robert C; Dixon, Douglas R; Goksel, Tamer; Castle, James T; Henry, Walter A

    2013-03-01

    A 39-year-old African American woman presented for treatment of a symptomatic mandibular right first molar with a large, periapical radiolucency. After initial attempts at endodontic therapy, this tooth was ultimately extracted owing to unabated symptoms. The extraction site underwent ridge preservation grafting, implant placement, and restoration. After 26 months of implant function, the patient returned with clinical symptoms of pain, buccal swelling, and the sensation of a "loose" implant. This case report details a diagnosis of 2 distinct disease entities associated with the implant site, a cemento-ossifying fibroma and florid cemento-osseous dysplasia of the mandible. This diagnosis was determined from clinical, surgical, radiographic, and histopathologic evidence after biopsy and removal of the previously osseointegrated implant following postinsertion failure by fibrous encapsulation. Before implant therapy, it is essential to conduct a thorough radiographic evaluation of any dental arch with suspected bony lesions to prevent implant failure. Published by Mosby, Inc.

  16. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty.

    PubMed

    Zafar, Andleeb; Aslanides, Ioannis M; Selimis, Vasileios; Tsoulnaras, Konstantinos I; Tabibian, David; Kymionis, George D

    2018-01-01

    We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK), and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye.

  17. Analysis of professional malpractice claims in implant dentistry in Italy from insurance company technical reports, 2006 to 2010.

    PubMed

    Pinchi, Vilma; Varvara, Giuseppe; Pradella, Francesco; Focardi, Martina; Donati, Michele D; Norelli, Gianaristide

    2014-01-01

    The aim of the study was to analyze the characteristics of implant dentistry claims in Italy based on insurance company technical reports for malpractice claims. One hundred twenty-one technical reports of cases of professional malpractice in implant dentistry between 2006 and 2010 were included in the study. Data included the sex and age of the patient and dentist, the kind of negligence claimed, and the damages awarded as a consequence of the alleged misconduct. Of the cases examined in this study, 9.9% went to court. The patients were female in 73.6% of the cases. Most of the technical errors were committed during implant insertion (82.6%). In 50.4% of cases, the technical error involved the surrounding structures, such as damage to the inferior alveolar nerve (32.2%) or the lingual nerve (2.5%), invasion of the maxillary sinus (9.1%), or pulpal dental necrosis in adjacent teeth (6.6%). Incomplete clinical documentation was apparent in 54.5% of cases. In 9.9% of cases, a civil suit had already been filed before a visit, and medicolegal advice from the insurance expert had been procured. The discrepancy between the total number of cases examined and those that went to court indicates that implant malpractice claims in Italy are most often settled out of court. The large number of intraoperative errors seen and the high proportion of injuries to surrounding structures suggest that implant dentists would benefit from further specific training. Also, clinical documentation vital to a defense against any claims relating to professional misconduct was incomplete or absent in more than half of the cases.

  18. Intracameral air injection during Ahmed glaucoma valve implantation in neovascular glaucoma for the prevention of tube obstruction with blood clot: Case Report.

    PubMed

    Hwang, Sung Ha; Yoo, Chungkwon; Kim, Yong Yeon; Lee, Dae Young; Nam, Dong Heun; Lee, Jong Yeon

    2017-12-01

    Glaucoma drainage implant surgery is a treatment option for the management of neovascular glaucoma. However, tube obstruction by blood clot after Ahmed glaucoma valve (AGV) implantation is an unpredictable clinically challenging situation. We report 4 cases using intracameral air injection for the prevention of the tube obstruction of AGV by blood clot. The first case was a 57-year-old female suffering from ocular pain because of a tube obstruction with blood clot after AGV implantation in neovascular glaucoma. Surgical blood clot removal was performed. However, intractable bleeding was noted during the removal of the blood clot, and so intracameral air injection was performed to prevent a recurrent tube obstruction. After the procedure, although blood clots formed around the tube, the tube opening where air could touch remained patent. In 3 cases of neovascular glaucoma with preoperative severe intraocular hemorrhages, intracameral air injection and AGV implantation were performed simultaneously. In all 3 cases, tube openings were patent. It appears that air impeded the blood clots formation in front of the tube opening. Intracameral air injection could be a feasible option to prevent tube obstruction of AGV implant with a blood clot in neovascular glaucoma with high risk of tube obstruction. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  19. Successful bone-anchored hearing aid implantation in a patient with osteogenesis imperfecta.

    PubMed

    Coutinho, M B; Marques, C; Mendes, G J; Gonçalves, C

    2015-11-01

    To report a case of successful bone-anchored hearing aid implantation in an adult patient with type III osteogenesis imperfecta, which is commonly regarded as a contraindication to this procedure. A 45-year-old man with type III osteogenesis imperfecta presented with mixed hearing loss. There was a mild sensorineural component in both ears, with an air-bone gap between 45 and 50 dB HL. He was implanted with a bone-anchored hearing aid. The audiological outcome was good, with no complications and good implant stability (as measured by resonance frequency analysis). To our knowledge, this is the first recorded case of bone-anchored hearing aid implantation in a patient with osteogenesis imperfecta.

  20. The use of interlocking prostheses for both temporary and definitive management of infected periprosthetic femoral fractures.

    PubMed

    Konan, Sujith; Rayan, Faizal; Manketelow, Andrew R J; Haddad, Fares S

    2011-12-01

    Infected periprosthetic fractures around total hip arthroplasties are an extremely challenging problem. We describe our experience of managing infected periprosthetic femoral fractures using interlocking long-stem femoral prostheses either as temporary functional spacers or as definitive implants. The Cannulock (Orthodesign, Christchurch, United Kingdom) uncoated stem was used in 12 cases, and the Kent hip prosthesis (Biomet Merck, Bridgend, United Kingdom), in 5 cases. Satisfactory outcome was noted in all cases, and in 11 cases, revision to a definitive stem has been undertaken after successful control of infection and fracture union. The use of interlocking stems offers a relatively appealing solution for a complex problem and avoids the complications that would be associated with resection of the entire femur or the use of large quantities of bone cement. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Breast Reconstruction with Implants

    MedlinePlus

    ... implants is a complex procedure performed by a plastic surgeon. The breast reconstruction process can start at ... doctor may recommend that you meet with a plastic surgeon. Consult a plastic surgeon who's board certified ...

  2. Development of personalized annuloplasty rings: combination of CT images and CAD-CAM tools.

    PubMed

    Díaz Lantada, Andrés; Valle-Fernández, Raquel Del; Morgado, Pilar Lafont; Muñoz-García, Julio; Muñoz Sanz, José Luis; Munoz-Guijosa, Juan Manuel; Otero, Javier Echávarri

    2010-02-01

    Although the use of personalized annuloplasty rings manufactured for each patient according to the size and morphology of their valve complex could be beneficial for the treatment of mitral insufficiency, this possibility has been limited for reasons of time-lines and costs as well as for design and manufacturing difficulties, as has been the case with other personalized implant and prosthetic developments. However, the present quality of medical image capture equipment together with the benefits to be had from computer-aided design and manufacturing technologies (CAD-CAM) and the capabilities furnished by rapid prototyping technologies, present new opportunities for a personalized response to the development of implants and prostheses, the social impact of which could turn out to be highly positive. This paper sets out a personalized development of an annuloplasty ring based on the combined use of information from medical imaging, from CAD-CAM design programs and prototype manufacture using rapid prototyping technologies.

  3. Successful Implantation of a Left Ventricular Assist Device in a Patient with Heparin-Induced Thrombocytopenia and Thrombosis

    PubMed Central

    Garland, Cassandra; Somogyi, David

    2014-01-01

    Abstract: We report the case of a 27-year-old woman with signs of heparin-induced thrombocytopenia and thrombosis (HITT) and left heart failure presenting for urgent implantation of a left ventricular assist device (LVAD). HITT can occur in 4.2–6.1% of patients with LVADs. If the patient remains hemodynamically stable, implantation can be delayed for several months until the heparin/PF-4 antibodies decline allowing the use of heparin on cardiopulmonary bypass, However, in most cases related to cardiogenic shock, surgery cannot be delayed. We present the case of a patient who underwent implantation of a HeartMate II LVAD and discuss management strategy using bivalirudin during cardiopulmonary bypass. PMID:25208434

  4. Diode Laser and Periodontal Regeneration-Assisted Management of Implant Complications in Anterior Maxilla.

    PubMed

    Salaria, Sanjeev Kumar; Sharma, Isha; Brar, Navjot Kaur; Kaur, Satwant

    2018-01-01

    Dental implant is being considered successful if the patient is pleased with both of its functional and esthetic outcome. As implant complications (such as peri-implantitis, inappropriate implant position, wrong angulation, and implant location too close to anatomical structures) have been frequently encountered in dental practice, therefore, thorough knowledge to manage such complications is the key prerequisite to prevent the failure of implant. The present case report discussed the etiology, diagnosis of early peri-implantitis, and periodontal abscess with their successful management through periodontal regeneration and diode laser-assisted therapy.

  5. Computed-tomography modeled polyether ether ketone (PEEK) implants in revision cranioplasty.

    PubMed

    O'Reilly, Eamon B; Barnett, Sam; Madden, Christopher; Welch, Babu; Mickey, Bruce; Rozen, Shai

    2015-03-01

    Traditional cranioplasty methods focus on pre-operative or intraoperative hand molding. Recently, CT-guided polyether ether ketone (PEEK) plate reconstruction enables precise, time-saving reconstruction. This case series aims to show a single institution experience with use of PEEK cranioplasty as an effective, safe, precise, reusable, and time-saving cranioplasty technique in large, complex cranial defects. We performed a 6-year retrospective review of cranioplasty procedures performed at our affiliated hospitals using PEEK implants. A total of nineteen patients underwent twenty-two cranioplasty procedures. Pre-operative, intra-operative, and post-operative data was collected. Nineteen patients underwent twenty-two procedures. Time interval from injury to loss of primary cranioplasty averaged 57.7 months (0-336 mo); 4.0 months (n=10, range 0-19) in cases of trauma. Time interval from primary cranioplasty loss to PEEK cranioplasty was 11.8 months for infection (n=11, range 6-25 mo), 12.2 months for trauma (n=5, range 2-27 mo), and 0.3 months for cosmetic or functional reconstructions (n=3, range 0-1). Similar surgical techniques were used in all patients. Drains were placed in 11/22 procedures. Varying techniques were used in skin closure, including adjacent tissue transfer (4/22) and free tissue transfer (1/22). The PEEK plate required modification in four procedures. Three patients had reoperation following PEEK plate reconstruction. Cranioplasty utilizing CT-guided PEEK plate allows easy inset, anatomic accuracy, mirror image aesthetics, simplification of complex 3D defects, and potential time savings. Additionally, it's easily manipulated in the operating room, and can be easily re-utilized in cases of intraoperative course changes or infection. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Breast reconstruction of an unusual configuration using two paranemic implants.

    PubMed

    Ishii, Naohiro; Ando, Jiro; Harao, Michiko; Takemae, Masaru

    2017-12-01

    Implant-based breast reconstruction can be performed using a choice of various types of breast implants. However, cases where the breast shapes are unsuitable for implant-based reconstruction method are occasionally encountered. We present two patients with wide trunks who underwent breast reconstruction using an unusual configuration that involved a latissimus dorsi myocutaneous flap combined with two paranemic implants.

  7. Removable partial denture supported by implants with prefabricated telescopic abutments - a case report.

    PubMed

    Kumar, Lalit; Sehgal, Komal

    2014-06-01

    Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy-biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs.

  8. Macrotextured Breast Implants with Defined Steps to Minimize Bacterial Contamination around the Device: Experience in 42,000 Implants.

    PubMed

    Adams, William P; Culbertson, Eric J; Deva, Anand K; R Magnusson, Mark; Layt, Craig; Jewell, Mark L; Mallucci, Patrick; Hedén, Per

    2017-09-01

    Bacteria/biofilm on breast implant surfaces has been implicated in capsular contracture and breast implant-associated anaplastic large-cell lymphoma (ALCL). Macrotextured breast implants have been shown to harbor more bacteria than smooth or microtextured implants. Recent reports also suggest that macrotextured implants are associated with a significantly higher incidence of breast implant-associated ALCL. Using techniques to reduce the number of bacteria around implants, specifically, the 14-point plan, has successfully minimized the occurrence of capsular contracture. The authors hypothesize that a similar effect may be seen in reducing the risk of breast implant-associated ALCL. Pooled data from eight plastic surgeons assessed the use of macrotextured breast implants (Biocell and polyurethane) and known cases of breast implant-associated ALCL. Surgeon adherence to the 14-point plan was also analyzed. A total of 42,035 Biocell implants were placed in 21,650 patients; mean follow-up was 11.7 years (range, 1 to 14 years). A total of 704 polyurethane implants were used, with a mean follow-up of 8.0 years (range, 1 to 20 years). The overall capsular contracture rate was 2.2 percent. There were no cases of implant-associated ALCL. All surgeons routinely performed all 13 perioperative components of the 14-point plan; two surgeons do not routinely prescribe prophylaxis for subsequent unrelated procedures. Mounting evidence implicates the role of a sustained T-cell response to implant bacteria/biofilm in the development of breast implant-associated ALCL. Using the principles of the 14-point plan to minimize bacterial load at the time of surgery, the development and subsequent sequelae of capsular contracture and breast implant-associated ALCL may be reduced, especially with higher-risk macrotextured implants. Therapeutic, IV.

  9. Performance of a radio link between a base station and a medical implant utilising the MICS standard.

    PubMed

    Johansson, Anders J

    2004-01-01

    Modern medical implants are of increasing complexity and with that, the need for fast and flexible communication with them grows. A wireless system is preferable and an inductive link is the most commonly used. But it has the drawback of a very short range, essentially limited to having the external transceiver touching the patient. The Medical Implant Communication System, MICS, is a standard aimed at improving the communication distance. It operates at a higher frequency band between 402 MHz and 405 MHz. We have by simulations and measurements investigated the channel properties of this band and calculated the link performance for a typical implant application. The result is a link speed between a base station and a bedridden patient of 600 kbit bits per second with a bit error rate of 2% in the downlink to the implant and 1 % in the uplink to the base station. Conclusions on the necessary complexity of the base station are also given.

  10. Laser characterization of the depth profile of complex refractive index of PMMA implanted with 50 keV silicon ions

    NASA Astrophysics Data System (ADS)

    Stefanov, Ivan L.; Stoyanov, Hristiyan Y.; Petrova, Elitza; Russev, Stoyan C.; Tsutsumanova, Gichka G.; Hadjichristov, Georgi B.

    2013-03-01

    The depth profile of the complex refractive index of silicon ion (Si+) implanted polymethylmethacrylate (PMMA) is studied, in particular PMMA implanted with Si+ ions accelerated to a relatively low energy of 50 keV and at a fluence of 3.2 × 1015 cm-2. The ion-modified material with nano-clustered structure formed in the near(sub)surface layer of a thickness of about 100 nm is optically characterized by simulation based on reflection ellipsometry measurements at a wavelength of 632.8 nm (He-Ne laser). Being of importance for applications of ion-implanted PMMA in integrated optics, optoelectronics and optical communications, the effect of the index depth profile of Si+-implanted PMMA on the profile of the reflected laser beam due to laser-induced thermo-lensing in reflection is also analyzed upon illumination with a low power cw laser (wavelength 532 nm, optical power 10 - 50 mW).

  11. Cochlear Implants and Psychiatric Assessments: a Norrie Disease Case Report.

    PubMed

    Jacques, Denis; Dubois, Thomas; Zdanowicz, Nicolas; Gilain, Chantal; Garin, Pierre

    2017-09-01

    It is important to perform psychiatric assessments of adult patients who are candidates for cochlear implants both to screen them for psychiatric disorders and to assess their understanding and compliance with the procedure. Deafness is a factor of difficulty for conducting in-depth psychiatric interviews, but concomitant blindness may make it impossible. After a description of Norrie disease, a rare disease in which blindness and deafness may occur together, we propose a case report of a patient suffering from the disease and who consulted in view of a cochlear implant. Early information on cochlear implants appears to be necessary before total deafness occurs in patients suffering from Norrie disease. An inventory of digital communication tools that can be used by the patient is also highly valuable. Research should be supported for a more systematic use of psychiatric assessments prior to cochlear implants. In the special case of Norrie disease, we recommend early screening for mental retardation and related psychotic disorders and, depending on the patient's level of understanding, preventive information on the benefits and limits of cochlear implants before total deafness occurs.

  12. Reactive oral lesions associated with dental implants. A systematic review.

    PubMed

    Atarbashi-Moghadam, Fazele; Atarbashi-Moghadam, Saede; Namdari, Mahshid; Shahrabi-Farahani, Shokoufeh

    2018-05-11

    Reactive lesion formation around dental implants a complication that has been given much consideration. These lesions can lead to marginal bone loss, and consequently, implant failure. In the present systematic review, all reported reactive lesions associated with dental implants in the literature were assessed. An electronic search was performed using PubMed Central, Scopus, Google Scholar, and Science Direct. The search strategy was limited to human studies (case reports and case series), full-text English language articles, published until May 2017. A total of 19 articles reporting 27 lesions in 25 cases were included. Peripheral giant cell granuloma and pyogenic granuloma were the most reactive lesions found around dental implants. The mean age of the patients was 51.28 ± 14.48 years, with a slight female predilection. Posterior mandibular gingiva was the most common location for these lesions. The recurrence rate of lesions was 33.33%, and the chance of implant removal was 29.62%. Due to the clinical significance of these lesions, early histopathologic examination is recommended to exclude the presence of such pathological lesions. © 2018 John Wiley & Sons Australia, Ltd.

  13. Effect of surface treatment on stress distribution in immediately loaded dental implants--a 3D finite element analysis.

    PubMed

    Bahrami, Babak; Shahrbaf, Shirin; Mirzakouchaki, Behnam; Ghalichi, Farzan; Ashtiani, Mohammed; Martin, Nicolas

    2014-04-01

    To investigate, by means of FE analysis, the effect of surface roughness treatments on the distribution of stresses at the bone-implant interface in immediately loaded mandibular implants. An accurate, high resolution, digital replica model of bone structure (cortical and trabecular components) supporting an implant was created using CT scan data and image processing software (Mimics 13.1; Materialize, Leuven, Belgium). An anatomically accurate 3D model of a mandibular-implant complex was created using a professional 3D-CAD modeller (SolidWorks, DassaultSystèmes Solid Works Corp; 2011). Finite element models were created with one of the four roughness treatments on the implant fixture surface. Of these, three were surface treated to create a uniform coating determined by the coefficient of friction (μ); these were either (1) plasma sprayed or porous-beaded (μ=1.0), (2) sandblasted (μ=0.68) or (3) polished (μ=0.4). The fourth implant had a novel two-part surface roughness consisting of a coronal polished component (μ=0.4) interfacing with the cortical bone, and a body plasma treated surface component (μ=1) interfacing with the trabecular bone. Finite element stress analysis was carried out under vertical and lateral forces. This investigation showed that the type of surface treatment on the implant fixture affects the stress at the bone-implant interface of an immediately loaded implant complex. Von Mises stress data showed that the two-part surface treatment created the better stress distribution at the implant-bone interface. The results from this FE computational analysis suggest that the proposed two-part surface treatment for IL implants creates lower stresses than single uniform treatments at the bone-implant interface, which might decrease peri-implant bone loss. Future investigations should focus on mechanical and clinical validation of these FE results. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. Immediate occlusal loading of double acid-etched surface titanium implants in 41 consecutive full-arch cases in the mandible and maxilla: 6- to 74-month results.

    PubMed

    Ibañez, Juan C; Tahhan, Marcelo J; Zamar, Juan A; Menendez, Alicia B; Juaneda, Agustina M; Zamar, Nicolas J; Monqaut, Jose L

    2005-11-01

    The high success rate of dental implants has changed the quality of life for many patients. Immediate loading finds its application in some clinical cases and certainly adds another modality of treatment for the implant patient. Starting with a few implants immediately loaded with a bar overdenture in the mandible, the concept of immediate loading evolved to loading multiple implants in both the maxilla and mandible. In this investigation, 41 consecutive patients who needed full-arch restorations were treated with 343 double acid-etched surface implants between May 1998 and March 2004. The sample included smokers and bruxers. Twenty-three mandibular and 26 maxillary cases were treated, loading the implants within 48 hours, by using resin provisional prostheses, metal-reinforced provisional prostheses, or definitive prostheses (metal-acrylic or metal-ceramic). All implants were followed for 12 to 74 months. Follow-up consisted of clinical as well as radiographic examination. Furthermore, resonance frequency analysis was done in most of the implants during the last 2 years. The success rate obtained was 99.42% (only two mandibular implants that are still surviving were considered failures). The bone level was measured every year. The average radiographic bone level change was 0.56 mm at 12, 0.76 mm at 24, 0.84 mm at 36, 0.82 mm at 48, 0.83 mm at 60, and 0.94 mm at 72 months. A high success rate can be achieved when double acid-etched surface implants are immediately loaded with fixed full-arch restorations in the maxilla and mandible.

  15. Poly Implant Prothèse (PIP) incidence of rupture: a retrospective MR analysis in 64 patients

    PubMed Central

    Scotto di Santolo, Mariella; Cusati, Bianca; Ragozzino, Alfonso; Dell’Aprovitola, Nicoletta; Acquaviva, Alessandra; Altiero, Michele; Accurso, Antonello; Riccardi, Albina

    2014-01-01

    Aim of the study The purpose of this retrospective study was to describe the magnetic resonance imaging (MRI) features of Poly Implant Prothèse (PIP) hydrogel implants in a group of 64 patients and to assess the incidence of rupture, compared to other clinical trials. Material and methods In this double-center study, we retrospectively reviewed the data sets of 64 consecutive patients (mean age, 43±9 years, age range, 27-65 years), who underwent breast MRI examinations, between January 2008 and October 2013, with suspected implant rupture on the basis of clinical assessment or after conventional imaging examination (either mammography or ultrasound). All patients had undergone breast operation with bilateral textured cohesive gel PIP implant insertion for aesthetic reasons. The mean time after operation was 8 years (range, 6-14 years). No patients reported history of direct trauma to their implants. Results At the time of clinical examination, 41 patients were asymptomatic, 16 complained of breast tenderness and 7 had clinical evidence of rupture. Normal findings were observed in 15 patients. In 26 patients there were signs of mild collapse, with associated not significant peri-capsular fluid collections and no evidence of implant rupture; in 23 patients there was suggestion of implant rupture, according to breast MRI leading to an indication for surgery. In particular, 14 patients showed intra-capsular rupture, with associated evidence of the linguine sign in all cases; the keyhole sign and the droplet signs were observed in 6 cases. In 9 patients there was evidence of extra-capsular rupture, with presence of axillary collections (siliconomas) in 7 cases and peri-prosthetic and mediastinal cavity siliconomas, in 5 cases. Conclusions The results of this double center retrospective study, confirm the higher incidence (36%) of prosthesis rupture observed with the PIP implants, compared to other breast implants. PMID:25525578

  16. Very late stent thrombosis in a bare-metal stent, 9 years after implantation.

    PubMed

    Almasswary, Adel A

    2009-06-01

    Very late bare-metal stent thrombosis occurring beyond one year after stenting is uncommon. We report a case of bare-metal stent thrombosis presenting as acute myocardial infarction. The patient's stent was implanted 9 years ago, however, he was not adherent to his antiplatelet therapy (aspirin). This case highlights the importance of antiplatelet therapy in patients with stents even many years after implantation.

  17. [Radiological trap and oncological precautions in a patient who has undergone a permanent withdrawal of PIP breast implants].

    PubMed

    Koutsomanis, A; Bruant-Rodier, C; Roedlich, M-N; Bretz-Grenier, M-F; Perrot, P; Bodin, F

    2015-12-01

    We report the case of a 57-year-old patient who presented radiological images similar to ruptured breast implants one year after the supposed withdrawal of the latter. This woman had benefited for the first time from cosmetic PIP breast implants in 2000. Early in 2014, she requested the removal of the implants without renewal because she was feeling pain and functional discomfort. A few months after the operation, she consulted for breast swelling in the upper pole of the breast. Radiological assessment showed liquid formations compatible with the presence of implants. At our request, the rereading of the MRI by the radiologist definitively concluded on a bilateral seroma within the persistent fibrous capsule. In the absence of symptoms, clinical monitoring had been decided. But at the recrudescence of anaplastic large cell lymphoma cases associated with breast implants, a cytological sampling was intended. In case of cytological abnormality or recurrence of the seroma, a surgical procedure should be performed. In conclusion, the removal of a breast implant without capsulectomy may result in the formation of a seroma whose images resemble those of an implant. It is always worthwhile to provide precise clinical data to the radiologist in order to help him to make informed interpretations. Every serous effusion in a breast lodge having contained a silicone implant must evoke the diagnosis of anaplastic large cell lymphoma. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  18. Cochlear implantation through the round window with a straight slotted electrode array: optimizing the surgical procedure.

    PubMed

    Mom, Thierry; Bachy, Aurélie; Houette, Aubry; Pavier, Yoann; Pastourel, Rémy; Gabrillargues, Jean; Saroul, Nicolas; Gilain, Laurent; Avan, Paul

    2016-04-01

    The question addressed here is how optimizing the quality of insertion through the round window with the lower morbidity, when using a straight and slotted electrode array of regular length. This retrospective analysis includes all cases implanted with a cochlear implant Digisonic SP (Neurelec-Oticon Medical) since 2004. We checked the operative charts, the depth of insertion, and the follow-up. For comparisons, contingency tables were used and a Chi-square test was performed. A p value <0.05 was considered significant. 126 cases of patients with non-malformed cochleas were implanted through the round window. The mean age was 53.8 ± 16.2 for adults and 3.6 ± 2.6 for children (24 cases). The mean follow-up was 33 ± 22 months. The straight electrode array had either a square or a soft pointed tip (n = 84). Full insertion was achieved in 79 out of 84 cases with a soft tip vs. 18 out of 42 square tips (χ (2) = 41.41, DOF = 1, p < 0.0001). Two cases were stuck at the round window niche by a prominent crista fenestrae. In all cases but one, the chorda tympany was preserved. In one case, a misrouting to the vestibule required a revision surgery. Implantation through the round window with a straight and slotted electrode array with a soft tip (Digisonic SP, Neurelec-Oticon Medical) can lead to a full insertion in 94 % of cases. Drilling out a prominent crista fenestrae is recommended.

  19. A Midterm Review of Lesser Toe Arthrodesis With an Intramedullary Implant.

    PubMed

    Harmer, James Lee; Wilkinson, Anthony; Maher, Anthony John

    2017-10-01

    Lesser toe deformities are one of the most common conditions encountered by podiatric surgeons. When conservative treatments fail surgical correction is indicated. Many surgical options have been described to address the complex nature of these deformities but no perfect solution has been reported to date. However, with the continued advancement of internal fixation technology, interphalangeal joint (IPJ) arthrodesis with an intramedullary implant may be a good option. This retrospective study presents patient reported outcomes and complications at 6 months and 3 years following lesser toe proximal interphalangeal joint (PIPJ) arthrodesis with a polyketone intrameduallary implant (Toe Grip, Orthosolutions, UK). Between September 2011 and November 2012, a total of 38 patients attended for second toe PIPJ arthrodesis by means of the Toe Grip device. At 6 months postoperation, 94.7% of patients and at 3 years postoperation, 92.8% of patients felt that their original complaint was better or much better. Health-related quality of life scores continued to improve overtime as measured by the Manchester Oxford Foot Questionnaire. Complications were generally observational and asymptomatic. The most common complications were floating toes (17.8%), mallet deformities (14.2%), metatarsalgia (17.8%), and transverse plane deformity of the toe (10.7%). This study demonstrates excellent patient-eported outcomes with minimal symptomatic complications making the "Toe Grip" implant a safe and effective alternative fixation device for IPJ arthrodesis when dealing with painful digital deformities. Therapeutic, Level IV: Case series.

  20. A Retrospective Case Series of Surgical Implant Generation Network (SIGN) Placement at the Afghan National Police Hospital, Kabul, Afghanistan.

    PubMed

    Ertl, Christian W; Royal, David; Arzoiey, Humayoon Abdul; Shefa, Azizullah; Sultani, Salim; Mosafa, Mohammed Omar; Sadat, Safiullah; Zirkle, Lewis

    2016-01-01

    In Afghanistan, adequate and cost-effective medical care for even routine conditions is lacking; especially for complex injuries like long-bone fractures. The Surgical Implant Generation Network (SIGN) intramedullary nail is used for treatment of long-bone fractures from blunt injuries and does not require imaging. We are reporting for the first time results of the SIGN intramedullary nail at the Afghan National Police Hospital, a tertiary care facility in Kabul. 71 records from the SIGN Online Surgical Database were reviewed for gender, age, date of injury, implant date, patient's home of record, and type/ mechanism of injury. Mean age was 26.7 years, all but one being male; time from injury to implant ranged 1 to 401 days, with mean of 40.6 days. Long-bone fractures from motor vehicle accidents remained constant, and war injuries peaked in summer. Follow-up is limited because of security and financial burdens of travel. However, personal communication with Afghan National Police Hospital surgeons suggests that patients included in the current study have not experienced any adverse outcomes. While it remains to be seen if the SIGN Online Surgical Database will facilitate more comprehensive outcome studies, our results provide support for the efficacy of SIGN nails in treating long-bone fractures from war injuries. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  1. Electromagnetic Radiation Efficiency of Body-Implanted Devices

    NASA Astrophysics Data System (ADS)

    Nikolayev, Denys; Zhadobov, Maxim; Karban, Pavel; Sauleau, Ronan

    2018-02-01

    Autonomous wireless body-implanted devices for biotelemetry, telemedicine, and neural interfacing constitute an emerging technology providing powerful capabilities for medicine and clinical research. We study the through-tissue electromagnetic propagation mechanisms, derive the optimal frequency range, and obtain the maximum achievable efficiency for radiative energy transfer from inside a body to free space. We analyze how polarization affects the efficiency by exciting TM and TE modes using a magnetic dipole and a magnetic current source, respectively. Four problem formulations are considered with increasing complexity and realism of anatomy. The results indicate that the optimal operating frequency f for deep implantation (with a depth d ≳3 cm ) lies in the (108- 109 )-Hz range and can be approximated as f =2.2 ×107/d . For a subcutaneous case (d ≲3 cm ), the surface-wave-induced interference is significant: within the range of peak radiation efficiency (about 2 ×108 to 3 ×109 Hz ), the max-to-min ratio can reach a value of 6.5. For the studied frequency range, 80%-99% of radiation efficiency is lost due to the tissue-air wave-impedance mismatch. Parallel polarization reduces the losses by a few percent; this effect is inversely proportional to the frequency and depth. Considering the implantation depth, the operating frequency, the polarization, and the directivity, we show that about an order-of-magnitude efficiency improvement is achievable compared to existing devices.

  2. Three dimensional rotational angiography for assessment of coronary arteries during melody valve implantation: introducing a technique that may improve outcomes.

    PubMed

    Pockett, C R; Moore, J W; El-Said, H G

    2017-02-01

    Adverse events from Melody valve implantation may be catastrophic. To date a role for three dimensional rotational angiography of the aortic root (3DRAA) during Melody valve implantation has not been established. To describe the role of 3DRAA in the assessment of Melody valve candidacy and to demonstrate that it may improve outcomes. All patients who underwent cardiac catheterisation for Melody valve implantation and 3DRAA between August 2013 and February 2015 were reviewed. 31 patients had 3DRAA with balloon sizing. Ten were deemed not Melody candidates (5 coronary compression, 2 aortic root distortion with cusp flattening, 2 RVOT was too large, and 1 had complex branch stenosis and a short landing zone). Of the 21 patients who were Melody candidates, 12 had conduits, 6 prosthetic valves and 3 native RVOTs. In patients with conduits, the technique of stenting the conduit prior to dilation was used after measuring the distance between the conduit and the coronary arteries on 3DRAA. In the Melody patients, we had 100% procedural success and no serious adverse events (coronary compression, tears, stent fracture or endocarditis). As a tool for case selection, 3DRAA may facilitate higher procedural success and decreased risk of serious adverse events. Furthermore, 3D rotational angiography allows stenting of the conduit prior to dilation, which may prevent tears and possibly endocarditis.

  3. Comparing Binaural Pre-processing Strategies II: Speech Intelligibility of Bilateral Cochlear Implant Users.

    PubMed

    Baumgärtel, Regina M; Hu, Hongmei; Krawczyk-Becker, Martin; Marquardt, Daniel; Herzke, Tobias; Coleman, Graham; Adiloğlu, Kamil; Bomke, Katrin; Plotz, Karsten; Gerkmann, Timo; Doclo, Simon; Kollmeier, Birger; Hohmann, Volker; Dietz, Mathias

    2015-12-30

    Several binaural audio signal enhancement algorithms were evaluated with respect to their potential to improve speech intelligibility in noise for users of bilateral cochlear implants (CIs). 50% speech reception thresholds (SRT50) were assessed using an adaptive procedure in three distinct, realistic noise scenarios. All scenarios were highly nonstationary, complex, and included a significant amount of reverberation. Other aspects, such as the perfectly frontal target position, were idealized laboratory settings, allowing the algorithms to perform better than in corresponding real-world conditions. Eight bilaterally implanted CI users, wearing devices from three manufacturers, participated in the study. In all noise conditions, a substantial improvement in SRT50 compared to the unprocessed signal was observed for most of the algorithms tested, with the largest improvements generally provided by binaural minimum variance distortionless response (MVDR) beamforming algorithms. The largest overall improvement in speech intelligibility was achieved by an adaptive binaural MVDR in a spatially separated, single competing talker noise scenario. A no-pre-processing condition and adaptive differential microphones without a binaural link served as the two baseline conditions. SRT50 improvements provided by the binaural MVDR beamformers surpassed the performance of the adaptive differential microphones in most cases. Speech intelligibility improvements predicted by instrumental measures were shown to account for some but not all aspects of the perceptually obtained SRT50 improvements measured in bilaterally implanted CI users. © The Author(s) 2015.

  4. Reconstruction of a large calvarial traumatic defect using a custom-made porous hydroxyapatite implant covered by a free latissimus dorsi muscle flap in an 11-year-old patient.

    PubMed

    Morice, Anne; Kolb, Frédéric; Picard, Arnaud; Kadlub, Natacha; Puget, Stéphanie

    2017-01-01

    Reconstruction of complex skull defects requires collaboration between neurosurgeons and plastic surgeons to choose the most appropriate procedure, especially in growing children. The authors describe herein the reconstruction of an extensive traumatic bone and soft tissue defect of the cranial vault in an 11-year-old boy. The size of the defect, quality of the tissues, and patient's initial condition required a 2-stage approach. Ten months after an initial emergency procedure in which lacerated bone and soft tissue were excised, reconstruction was performed. The bone defect, situated on the left frontoparietal region, was 85 cm 2 and was filled by a custom-made porous hydroxyapatite implant. The quality of the overlying soft tissue did not allow the use of classic local and locoregional coverage techniques. A free latissimus dorsi muscle flap branched on the contralateral superficial temporal pedicle was used and left for secondary healing to take advantage of scar retraction and to minimize alopecia. Stable well-vascularized implant coverage as well as an esthetically pleasing skull shape was achieved. Results in this case suggest that concomitant reconstruction of large calvarial defects by cranioplasty with a custom-made hydroxyapatite implant covered by a free latissimus dorsi muscle flap is a safe and efficient procedure in children, provided that there is no underlying infection of the operative site.

  5. Clinical peri-implant sounding accuracy in the presence of chronic inflammation of peri-implant tissues. Clinical observation study.

    PubMed

    Romeo, E; Lops, D; Storelli, S; Ghisolfi, M

    2009-03-01

    The aim of this study was to assess if the probing pocket depth is a reliable clinical parameter in the evaluation of the depth of the peri-implant sulci. In case of chronic inflamed peri-implant tissues, this evaluation is useful for understanding the level of bone resorption. The study enrolled 22 patients. All of them were diagnosed for a peri-implantitis and were scheduled for a resective surgery with implantoplasty. During the surgery, a full thickness flap was raised and resective surgery was performed as well as an implantoplasty procedure. Peri-implant probing values before the surgery (PAL) were recorded, as were values of bone resorption after flap elevation (DIB), at all four sites around each implant (88 sites). The mean value of PAL calculated for all 88 sites was 5.67 mm (+/-1.46); the correspondent value of DIB was 6.37 mm (+/-1.81). In 52 sites out of 88 (59.1%) the values of PAL and DIB were exactly the same (maximum difference 0.5 mm). In only 10 cases (11.3%) the difference between PAL and DIB was >2 mm. The mean values for PAL and DIB were not statistically different. Authors have concluded that in case of chronic inflammation of peri-implant tissues, the probe reaches the bone pick, allowing the clinician to have reliable information on the actual bone resorption.

  6. Pedicle screw loosening is correlated to chronic subclinical deep implant infection: a retrospective database analysis.

    PubMed

    Leitner, Lukas; Malaj, Isabella; Sadoghi, Patrick; Amerstorfer, Florian; Glehr, Mathias; Vander, Klaus; Leithner, Andreas; Radl, Roman

    2018-04-13

    Spinal fusion is used for treatment of spinal deformities, degeneration, infection, malignancy, and trauma. Reduction of motion enables osseous fusion and permanent stabilization of segments, compromised by loosening of the pedicle screws (PS). Deep implant infection, biomechanical, and chemical mechanisms are suspected reasons for loosening of PS. Study objective was to investigate the frequency and impact of deep implant infection on PS loosening. Intraoperative infection screening from wound and explanted material sonication was performed during revision surgeries following dorsal stabilization. Case history events and factors, which might promote implant infections, were included in this retrospective survey. 110 cases of spinal metal explantation were included. In 29.1% of revision cases, infection screening identified a germ, most commonly Staphylococcus (53.1%) and Propionibacterium (40.6%) genus. Patients screened positive had a significant higher number of previous spinal operations and radiologic loosening of screws. Patients revised for adjacent segment failure had a significantly lower rate of positive infection screening than patients revised for directly implant associated reasons. Removal of implants that revealed positive screening effected significant pain relief. Chronic implant infection seems to play a role in PS loosening and ongoing pain, causing revision surgery after spinal fusion. Screw loosening and multiple prior spinal operations should be suspicious for implant infection after spinal fusion when it comes to revision surgery. These slides can be retrieved under Electronic Supplementary Material.

  7. [Audiophonological evaluation of 16 children fitted with cochlear implants for sensorineural hearing loss induced by bacterial meningitis].

    PubMed

    Teissier, N; Doehring, I; Noel-Petroff, N; Elmaleh-Bergès, M; Viala, P; François, M; Faye, A; Van Den Abbeele, T; Lorrot, M

    2013-06-01

    Bacterial meningitis (BM) is the primary etiology of acquired sensorineural hearing loss (SNHL) in children and may compromise language development. Since the 1990 s, cochlear implants (CIs) have become part of the management of children with profound SNHL with encouraging results. The aim of this study was to analyze the audiophonological performance of children before and after cochlear implantation for SNHL following bacterial meningitis. Retrospective study of all children fitted with CIs for bilateral severe to profound SNHL after bacterial meningitis in the Robert-Debré pediatric ENT department between August 1990 and March 2009. Audiophonological performance was assessed using the APCEI profile. Of the 283 children receiving implants during that period, 16 children (6%; 6 boys, 10 girls) underwent CI implantation after bacterial meningitis (Streptococcus pneumoniae in 8 cases, Neisseria meningitidis in 2 cases, and Haemophilus influenzae in 4 cases). The mean time from meningitis to SNHL was 8.3 months (median, 1.5 months; range, 1 day to 13 years). The mean time from meningitis to cochlear implantation was 2 years and 3 months (median, 7 months; range, 1 month to 13 years 3 months). Twelve children (75%) presented partial cochlear and/or vestibular ossification on presurgical CT scan. Three children received bilateral implants. Thirteen children (81%) developed early SNHL in the first 3 months, whereas 3 children developed SNHL more than 10 months after meningitis. As for the benefits of cochlear implantation, 11 children presented near to normal intelligibility and optimal use of their cochlear implant; 5 children presented partial benefits due to neurological sequelae (1), a long delay before implantation (1), technical problems (2), or a social problem in relation to low socioeconomic status (1). After bacterial meningitis, audiological evaluation must be made carefully during the first 3 months to detect early SNHL, but SNHL may also develop several years later. In case of profound SNHL and a modified signal of the labyrinth on the MRI, cochlear implantation must be performed without delay before cochlear and/or vestibular ossification. Cochlear implantation is an effective technique with good long-term audiologic results. The coexistence of neurological lesions may compromise the results, but it should not contraindicate a cochlear implantation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  8. Optimization in multi-implant placement for immediate loading in edentulous arches using a modified surgical template and prototyping: a case report.

    PubMed

    Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior

    2008-01-01

    Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.

  9. Is very early hearing assessment always reliable in selecting patients for cochlear implants? A case series study.

    PubMed

    Bovo, R; Trevisi, P; Ghiselli, S; Benatti, A; Martini, A

    2015-05-01

    This study concerns a case series of 23 infants with a diagnosis of severe-to-profound hearing loss at 3 months old, who significantly improved (even reaching a normal auditory threshold) within their first year of life. All infants were routinely followed up with audiological tests every 2 months after being fitted with hearing aids as necessary. A reliable consistency between the various test findings (DPOAE, ABR, behavioral responses, CAEP and ECoG) clearly emerged in most cases during the follow-up, albeit at different times after birth. The series of infants included 7 cases of severe prematurity, 6 of cerebral or complex syndromic malformations, 5 healthy infants, 2 with asymptomatic congenital CMV infection, and 1 case each of hyperbilirubinemia, hypoxia, and sepsis. All term-born infants showed a significant improvement over their initial hearing threshold by 6 months of age, while in most of those born prematurely the first signs of threshold amelioration occurred beyond 70 weeks of gestational age, and even beyond 85 weeks in one case. Cochlear implantation (CI) should only be considered after a period of auditory stimulation and follow-up with electrophysiological and behavioral tests, and an accurate analysis of their correlation. In our opinion, CI can be performed after a period of 8 months in all term-born infants with persistent severe-to-profound hearing loss without risk of diagnostic error, whereas the follow-up for severely preterm infants should extend to at least 80 weeks of gestational age. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Computer-aided position planning of miniplates to treat facial bone defects

    PubMed Central

    Wallner, Jürgen; Gall, Markus; Chen, Xiaojun; Schwenzer-Zimmerer, Katja; Reinbacher, Knut; Schmalstieg, Dieter

    2017-01-01

    In this contribution, a software system for computer-aided position planning of miniplates to treat facial bone defects is proposed. The intra-operatively used bone plates have to be passively adapted on the underlying bone contours for adequate bone fragment stabilization. However, this procedure can lead to frequent intra-operatively performed material readjustments especially in complex surgical cases. Our approach is able to fit a selection of common implant models on the surgeon’s desired position in a 3D computer model. This happens with respect to the surrounding anatomical structures, always including the possibility of adjusting both the direction and the position of the used osteosynthesis material. By using the proposed software, surgeons are able to pre-plan the out coming implant in its form and morphology with the aid of a computer-visualized model within a few minutes. Further, the resulting model can be stored in STL file format, the commonly used format for 3D printing. Using this technology, surgeons are able to print the virtual generated implant, or create an individually designed bending tool. This method leads to adapted osteosynthesis materials according to the surrounding anatomy and requires further a minimum amount of money and time. PMID:28817607

  11. Computer-aided position planning of miniplates to treat facial bone defects.

    PubMed

    Egger, Jan; Wallner, Jürgen; Gall, Markus; Chen, Xiaojun; Schwenzer-Zimmerer, Katja; Reinbacher, Knut; Schmalstieg, Dieter

    2017-01-01

    In this contribution, a software system for computer-aided position planning of miniplates to treat facial bone defects is proposed. The intra-operatively used bone plates have to be passively adapted on the underlying bone contours for adequate bone fragment stabilization. However, this procedure can lead to frequent intra-operatively performed material readjustments especially in complex surgical cases. Our approach is able to fit a selection of common implant models on the surgeon's desired position in a 3D computer model. This happens with respect to the surrounding anatomical structures, always including the possibility of adjusting both the direction and the position of the used osteosynthesis material. By using the proposed software, surgeons are able to pre-plan the out coming implant in its form and morphology with the aid of a computer-visualized model within a few minutes. Further, the resulting model can be stored in STL file format, the commonly used format for 3D printing. Using this technology, surgeons are able to print the virtual generated implant, or create an individually designed bending tool. This method leads to adapted osteosynthesis materials according to the surrounding anatomy and requires further a minimum amount of money and time.

  12. Putting 3D modelling and 3D printing into practice: virtual surgery and preoperative planning to reconstruct complex post-traumatic skeletal deformities and defects

    PubMed Central

    Tetsworth, Kevin; Block, Steve; Glatt, Vaida

    2017-01-01

    3D printing technology has revolutionized and gradually transformed manufacturing across a broad spectrum of industries, including healthcare. Nowhere is this more apparent than in orthopaedics with many surgeons already incorporating aspects of 3D modelling and virtual procedures into their routine clinical practice. As a more extreme application, patient-specific 3D printed titanium truss cages represent a novel approach for managing the challenge of segmental bone defects. This review illustrates the potential indications of this innovative technique using 3D printed titanium truss cages in conjunction with the Masquelet technique. These implants are custom designed during a virtual surgical planning session with the combined input of an orthopaedic surgeon, an orthopaedic engineering professional and a biomedical design engineer. The ability to 3D model an identical replica of the original intact bone in a virtual procedure is of vital importance when attempting to precisely reconstruct normal anatomy during the actual procedure. Additionally, other important factors must be considered during the planning procedure, such as the three-dimensional configuration of the implant. Meticulous design is necessary to allow for successful implantation through the planned surgical exposure, while being aware of the constraints imposed by local anatomy and prior implants. This review will attempt to synthesize the current state of the art as well as discuss our personal experience using this promising technique. It will address implant design considerations including the mechanical, anatomical and functional aspects unique to each case. PMID:28220752

  13. A hardware-algorithm co-design approach to optimize seizure detection algorithms for implantable applications.

    PubMed

    Raghunathan, Shriram; Gupta, Sumeet K; Markandeya, Himanshu S; Roy, Kaushik; Irazoqui, Pedro P

    2010-10-30

    Implantable neural prostheses that deliver focal electrical stimulation upon demand are rapidly emerging as an alternate therapy for roughly a third of the epileptic patient population that is medically refractory. Seizure detection algorithms enable feedback mechanisms to provide focally and temporally specific intervention. Real-time feasibility and computational complexity often limit most reported detection algorithms to implementations using computers for bedside monitoring or external devices communicating with the implanted electrodes. A comparison of algorithms based on detection efficacy does not present a complete picture of the feasibility of the algorithm with limited computational power, as is the case with most battery-powered applications. We present a two-dimensional design optimization approach that takes into account both detection efficacy and hardware cost in evaluating algorithms for their feasibility in an implantable application. Detection features are first compared for their ability to detect electrographic seizures from micro-electrode data recorded from kainate-treated rats. Circuit models are then used to estimate the dynamic and leakage power consumption of the compared features. A score is assigned based on detection efficacy and the hardware cost for each of the features, then plotted on a two-dimensional design space. An optimal combination of compared features is used to construct an algorithm that provides maximal detection efficacy per unit hardware cost. The methods presented in this paper would facilitate the development of a common platform to benchmark seizure detection algorithms for comparison and feasibility analysis in the next generation of implantable neuroprosthetic devices to treat epilepsy. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. Putting 3D modelling and 3D printing into practice: virtual surgery and preoperative planning to reconstruct complex post-traumatic skeletal deformities and defects.

    PubMed

    Tetsworth, Kevin; Block, Steve; Glatt, Vaida

    2017-01-01

    3D printing technology has revolutionized and gradually transformed manufacturing across a broad spectrum of industries, including healthcare. Nowhere is this more apparent than in orthopaedics with many surgeons already incorporating aspects of 3D modelling and virtual procedures into their routine clinical practice. As a more extreme application, patient-specific 3D printed titanium truss cages represent a novel approach for managing the challenge of segmental bone defects. This review illustrates the potential indications of this innovative technique using 3D printed titanium truss cages in conjunction with the Masquelet technique. These implants are custom designed during a virtual surgical planning session with the combined input of an orthopaedic surgeon, an orthopaedic engineering professional and a biomedical design engineer. The ability to 3D model an identical replica of the original intact bone in a virtual procedure is of vital importance when attempting to precisely reconstruct normal anatomy during the actual procedure. Additionally, other important factors must be considered during the planning procedure, such as the three-dimensional configuration of the implant. Meticulous design is necessary to allow for successful implantation through the planned surgical exposure, while being aware of the constraints imposed by local anatomy and prior implants. This review will attempt to synthesize the current state of the art as well as discuss our personal experience using this promising technique. It will address implant design considerations including the mechanical, anatomical and functional aspects unique to each case. © The Authors, published by EDP Sciences, 2017.

  15. Penile prostheses and the litigious patient: a legal database review.

    PubMed

    Sunaryo, Peter L; Colaco, Marc; Terlecki, Ryan

    2014-10-01

    Erectile dysfunction (ED) is a common problem with significant impact on patient quality of life. Penile prosthesis implantation provides an effective treatment for ED but as an invasive procedure carries with it an increased risk of medicolegal liability. To investigate factors associated with malpractice litigation surrounding penile prosthesis implantation. The Westlaw legal database was used to perform an advanced search for case reports using the term "medical malpractice" in combination with "penile" or "penis" and "prosthesis" or "implant" with dates between the January 1990 and December 2013. Each report was examined for trial information including patient demographics, device model and indications, alleged breach of duty, alleged damages, progression to trial, case outcome, and plaintiff award(s). The initial search yielded 76 cases that were narrowed to 40 after exclusions. There were 23 (57.5%) cases that were found in favor of the defendant, while 17 (42.5%) cases led to indemnity payment to the plaintiff including two cases (5.0%) that were settled out of court and 15 (37.5%) favoring the plaintiff in front of a jury. The mean settlement received was $335,500 compared with the mean indemnity award of $831,050 for verdicts decided in favor of the plaintiff (P = 0.68). The most common breach of duty was error in surgical decision making, present in 20 cases (48.8%). Informed consent was an issue in 13 filings (31.7%), and postoperative infection was seen in 13 cases (31.7%). In cases that identified the type of implant used, 58.3% were malleable implants, and 41.7% were inflatable devices. The main issues involved in malpractice litigation for penile prosthesis implants included surgical performance, informed consent, and postoperative management. Urologists must be aware of these potential issues in order to minimize their malpractice liability. © 2014 International Society for Sexual Medicine.

  16. Allograft for maxillary sinus floor augmentation: a retrospective study of 90 cases.

    PubMed

    Guerrero, Jaime S; Al-Jandan, Badr A

    2012-04-01

    The aim of this study is to demonstrate the clinical applicability and efficacy of an allograft for maxillary sinus augmentations in patients requiring placement of dental implants. Sixty consecutive patients underwent a total of 90 sinus augmentations. Twenty-nine were women and 31 men, with a mean age of 54 years. Twenty-six patients received a bilateral procedure and 34 unilateral. All cases were treated with the lateral wall technique. Allograft consisted of demineralized freeze-dried blocks in 6 cases, particulate in 82 cases, and a combination of both in 2 cases. In 30 patients, it was combined with platelet-rich plasma. A total of 84 implants were inserted. Bone samples of grafted areas were obtained in two patients for histological examination. Seventy-three implants were clinically successful at the reentry time. Eleven implants in seven patients were removed between 15 days and 6 months after their placement. Seven of these implants were replaced and received prostheses as well, for an overall postloading success rate of 95.2%. Follow-up for all patients after final restoration was between 12 and 96 months. Specimen's histological evaluation revealed bone formation and evidence of inflammatory infiltrate. Based on the findings of this study, it can be suggested that the use of the demineralized freeze-dried bone allograft from the Banco de Huesos y Tejidos Fundación Cosme y Damian for sinus augmentation is effective and constitutes a feasible therapeutic alternative for implant placement.

  17. Treatment planning: implant-supported partial overdentures.

    PubMed

    Chee, Winston W L

    2005-04-01

    When multiple anterior teeth are missing, many options of replacement are available. Traditionally, the choice was between a fixed or removable prostheses. Today, with the predictability of dental implants, the options of tooth replacement range from removable partial dentures to implant-supported fixed prostheses. The choice of which restoration that will best provide occlusion and esthetics depends on multiple factors including the number and location of missing teeth, the residual ridge form in relation to the replacement teeth, the relationship of the maxillary and mandibular anterior teeth, the condition of teeth adjacent to the edentulous span, the amount of bone available for implant placement, the patients "smile line" and display of teeth, lip support, and financial constraints. When there is minimal loss of the ridge contour, restorations that emerge from the ridge are the most functional and esthetic restorations, adhesive-type fixed partial dentures, conventional fixed partial dentures, and implant-supported restorations can be indicated with the choice of restoration dependent on a risk benefit and cost benefit analysis. When there is a loss of ridge contour due to residual ridge resorption or trauma, the decision becomes more complex as not only does the tooth structure need to be replaced, the ridge form also has to be replaced. (Figures 1 and 2). This can be assessed clinically as illustrated by Figures 1 and 2 where a dis crepancy in arch form and ridge form in relation to the adjacent teeth and/or opposing arch can be observed. Other considerations are lip support and display of the teeth when smiling. This article presents a case and rationale for implant-supported par tial overdentures. Many authors have written on the merits of com plete overdentures. The complete overdenture has proven to be an improvement over conventional complete prostheses with respect to chewing efficiency, patient comfort and satisfaction. In partial edentulism, the implant-supported overdenture has several advantages, some in common with a removable partial denture.

  18. Peri-implant plastic surgery techniques to hard and soft tissue augmentation in implant rehabilitation

    PubMed Central

    Baltacioğlu, Esra; Korkmaz, Yavuz Tolga; Korkmaz, Fatih Mehmet; Aydin, Güven; Sukuroglu, Erkan

    2017-01-01

    This report presents the clinical results of peri-implant plastic surgical approaches for hard and soft tissues before and during the implant placement in a patient with vertical ridge deformation and a shallow vestibule sulcus, and the subsequently performed prosthetic rehabilitation. The surgical approaches used in this case reduced the crown-height space and crown-to-implant ratio and ensured that the implants were placed in their ideal positions, and peri-implant tissue health was maintained. In conclusion, developments in the peri-implant plastic surgery enable the successful augmentation of hard and soft tissue defects and provide the implant-supported fixed prosthetic rehabilitation. PMID:29386805

  19. Cardiac resynchronization therapy with His bundle pacing as a method of treatment of chronic heart failure in patients with permanent atrial fibrillation and left bundle branch block.

    PubMed

    Boczar, Krzysztof; Sławuta, Agnieszka; Ząbek, Andrzej; Dębski, Maciej; Gajek, Jacek; Lelakowski, Jacek; Małecka, Barbara

    CRT is a therapeutic option for patients with heart failure, sinus rhythm, prolonged QRS complex duration and reduced ejection fraction. We present a case of 71-year-old woman with dilated cardiomyopathy, NYHA functional class III and AF. We implanted CRT combined with direct His-bundle pacing. The indication for such a therapy was a left bundle branch block with a QRS complex of 178ms and a left ventricular EF of 15%, left ventricular end-diastolic diameter (LVEDD) of 75mm. After 8months of follow-up the LVEDD was 60mm with EF 35-40%. Copyright © 2017. Published by Elsevier Inc.

  20. The Use of Ultrasound to Improve Axillary Vein Access and Minimize Complications during Pacemaker Implantation.

    PubMed

    Esmaiel, Abdullah; Hassan, Jeremy; Blenkhorn, Fay; Mardigyan, Vartan

    2016-05-01

    The Agency for Healthcare Research and Quality in the United States recommends the use of ultrasound (US) for central venous access to improve patient outcomes. However, in a recent publication, US is still underutilized for axillary vein access during pacemaker implantation. We sought to describe a technique for US-guided axillary vein access during pacemaker implantation and to report complication rates and success rate. Retrospective data collection included success rate and complications on all pacemaker implants by one operator since implementing the systematic use of US at our institution, from November 2012 to January 2015. For the last 59 cases, data were collected prospectively to include time of venous access and number of attempts. A total of 403 consecutive patients were included in the analysis. Two leads were implanted in 255 cases and one lead was implanted in 148 cases. The rate of successful US-guided access was 99.25%. There were no access-related complications. The average number of venipuncture attempts was 1.18 per patient. The average time to obtain venous access was 2.24 minutes including the time to apply the sterile US sleeve. The described technique has the potential to improve the success rate of axillary vein access and minimize complications during pacemaker implantation. ©2016 Wiley Periodicals, Inc.

  1. New operational techniques of implantation of biomaterials and titanium implants in the jaw with the atrophy of the bone and soft tissues

    NASA Astrophysics Data System (ADS)

    Nikityuk, D. B.; Urakov, A. L.; Reshetnikov, A. P.; Kopylov, M. V.; Baimurzin, D. Yu.

    2015-11-01

    The research into dynamics of quality of clinical use in 2003 - 2012 of autologous and xenogeneic biomaterials at dental transplantation and implantation among 1,100 of adult patients was made. The analysis results show that at autologous bone transplantation implant survival is observed only in 72% of cases, and the "necessary" result of bone repair occurred only in 6 - 9 months. Transplantation of biomaterials of OsteoBiol® (materials "mp3", "Genos" and "Evolution") provided engraftment and bone regeneration in 100 % of cases and allowed the use of dental implantation immediately after transplantation even in case of reduction in the patient's alveolar crest down to 2.0 mm. Replace Select implants of Nobel Biocare® were used at plantation. In order to exclude Schneiderian membrane's perforation lighting of Highmore's sinus with the cold blue-violet light from inside at sinus elevation is recommended as well as deepening of dental instruments into the bone only until the blue-violet light appears under them. To exclude deficiency of soft tissue under the cervical part of the ceramic crown application of special anti-fissure technology involving biomaterial flap dissection and its laying around the implant is suggested.

  2. Management of Children Using Cochlear Implants and Hearing Aids.

    ERIC Educational Resources Information Center

    Ching, Teresa Y. C.; Psarros, Colleen; Incerti, Paula; Hill, Mandy

    2001-01-01

    Four case studies identify six factors affecting successful use of a hearing aid with a cochlear implant: duration of hearing aid use prior to implantation, amount of residual hearing in the non-implanted ear, educational and listening demands, cosmetic issues, hearing aid rejection, and extended period of non-use of hearing aid. (Contains…

  3. Implant-retained dentures for full-arch rehabilitation: a case report comparing fixed and removable restorations.

    PubMed

    Zafiropoulos, Gregory-George; Hoffman, Oliver

    2011-01-01

    Dental implants as abutments for full-arch restorations are a well-documented treatment modality. This report presents a case in which the patient was treated initially with fixed restorations supported by either implants or natural teeth and subsequently treated with a removable implant/telescopic crown-supported overdenture. Advantages and disadvantages of each approach are described and discussed. While the fixed restoration resulted in a functionally satisfactory treatment outcome, the patient was displeased with the esthetic appearance. The main concern was the unnaturally long tooth shape necessary to compensate for the insufficient alveolar ridge height. Replacement of the existing restoration with an implant-supported removable overdenture led to a functionally and esthetically acceptable result. When deciding whether to use a fixed or removable implant-supported full-arch restoration, a multitude of factors must be considered. Due to the possible need for additional surgical steps to enhance the esthetic appearance surrounding fixed restorations, removable implant-supported partial dentures often are the better choice.

  4. Breast implants and anaplastic large-cell lymphoma: a danish population-based cohort study.

    PubMed

    Vase, Maja Ølholm; Friis, Søren; Bautz, Andrea; Bendix, Knud; Sørensen, Henrik Toft; d'Amore, Francesco

    2013-11-01

    A potential link between breast implants and anaplastic large-cell lymphoma (ALCL) has been suggested. We examined lymphoma occurrence in a nationwide cohort of 19,885 Danish women who underwent breast implant surgery during 1973-2010. Standardized incidence ratios (SIR), with 95% confidence intervals (CI), for ALCL and lymphoma overall associated with breast implantation were calculated. During 179,246 person-years of follow-up, we observed 31 cases of lymphoma among cohort members. No cases of ALCL were identified. SIRs for ALCL and lymphoma overall were zero (95% CI, 0-10.3) and 1.20 (95% CI, 0.82-1.70), respectively. In our nationwide cohort study, we did not find an increased risk of lymphoma in general, or ALCL in particular, among Danish women who underwent breast implantation. However, our evaluation of ALCL risk was limited by the rarity of the disease. Our results do not support an association between breast implants and ALCL and are consistent with other studies on cancer risk and breast implants. ©2013 AACR.

  5. Evaluation of the Effects of Dental Implants on Oral Lesions.

    PubMed

    Agha-Hosseini, Farzaneh; Rohani, Bita

    2015-05-01

    To determine whether dental implants impress oral lesions, and to evaluate the nature of their effect on the lesions. A comprehensive search was done via Google and PubMed for articles (including case reports and literature reviews) containing the keywords 'oral squamous cell carcinoma' (OSCC), 'oral lichen planus' (OLP), 'lichenoid contact reaction' (LCR), 'osseointegrated implants', and 'dental implants' , in the last 10 years (2002-2012). The study included 24 articles involving patients with dental implants, and some oral lesions (e.g. oral lichen planus and oral squamous cell carcinoma) or with a history of lesions. In these publications, there is evidence suggesting the possibility of emergence, exacerbation, recurrence, or even malignant transformation of the oral lesions after implant placement in some cases. Based on our review of the literature, implant treatment does not seem to be completely safe under any circumstances, but may have some complications in subjects with certain diseases (e.g. oral lesions, autoimmune diseases, malignancies, allergic reactions, etc.). Therefore prior to treatment, patients should be fully informed of the risks. Implant treatment is best done with caution in patients with cancer or mucocutaneous disorders.

  6. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty

    PubMed Central

    Zafar, Andleeb; Aslanides, Ioannis M.; Selimis, Vasileios; Tsoulnaras, Konstantinos I.; Tabibian, David; Kymionis, George D.

    2018-01-01

    Purpose We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. Methods The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK), and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Results Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. Conclusion A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye. PMID:29643797

  7. Continuous PECS II block for postoperative analgesia in patients undergoing transapical transcatheter aortic valve implantation.

    PubMed

    Shakuo, Tomoharu; Kakumoto, Shinichi; Kuribayashi, Junya; Oe, Katsunori; Seo, Katsuhiro

    2017-01-01

    It has been reported that PECS II block can alleviate postoperative pain following transapical transcatheter aortic valve implantation (TA-TAVI). However, the effectiveness of continuous PECS II block with catheterization has not yet been reported on the postoperative pain in patients undergoing TA-TAVI. We experienced two cases of TA-TAVI who received PECS II block with catheterization to manage postoperative pain. In the first case, a bolus injection for intraoperative pain and subsequent catheterization were performed before the implantation. However, the patient developed severe pain postoperatively in spite of the continuous block due to displacement of the catheter. In the second case, a bolus injection and the catheterization for the continuous block were performed before and after the implantation, respectively, which provided high-quality pain control. Continuous PECS II block may be useful to control perioperative pain associated with TA-TAVI. The insertion of the catheter after the implantation could be useful to avoid its displacement during the surgery.

  8. Application of the 2-piece orthodontic C-implant for provisional restoration with laser welded customized coping: a case report.

    PubMed

    Paek, Janghyun; Ahn, Hyo-Won; Jeong, Do-Min; Shim, Jeong-Seok; Kim, Seong-Hun; Chung, Kyu-Rhim

    2015-03-25

    This article presents the application of laser welding technique to fabricate an orthodontic mini-implant provisional restoration in missing area after limited orthodontic treatment. A 15-year-old boy case is presented. Two-piece orthodontic C-implant was placed after regaining space for missing right mandibular central incisor. Due to angular deviation of implant, customized abutment was required. Ready-made head part was milled and lingual part of customized abutment was made with non-precious metal. Two parts then were laser welded (Master 1000, Elettrolaser Italy, Verona, Italy) and indirect lab composite (3 M ESPE Sinfony, St. Paul, MN, USA) was built up. The patient had successful result, confirmed by clinical and radiographic examinations. Before the patient is ready to get a permanent restoration later on, this provisional restoration will be used. This case shows that a two-piece orthodontic C-implant system can be used to maintain small edentulous space after orthodontic treatment.

  9. Secondary abdominal appendicular ectopic pregnancy.

    PubMed

    Nama, Vivek; Gyampoh, Bright; Karoshi, Mahantesh; McRae, Reynold; Opemuyi, Isaac

    2007-01-01

    Although the case fatality rate for ectopic pregnancies has decreased to 0.08% in industrialized countries, it still represents 3.8% of maternal mortality in the United States alone. In developing countries, the case fatality rate varies from 3% to 27%. Laparoscopic management of tubal pregnancies is now the standard form of treatment where this technology is available. Abdominal pregnancies are rare, and secondary implantation of tubal ectopic pregnancies is the most common cause of abdominal gestations. We present an interesting case of secondary implantation of a tubal ectopic pregnancy to highlight the appendix as a possible secondary implantation site after a tubal ectopic pregnancy.

  10. An Intraoperative Site-specific Bone Density Device: A Pilot Test Case.

    PubMed

    Arosio, Paolo; Moschioni, Monica; Banfi, Luca Maria; Di Stefano, Anilo Alessio

    2015-08-01

    This paper reports a case of all-on-four rehabilitation where bone density at implant sites was assessed both through preoperative computed tomographic (CT) scans and using a micromotor working as an intraoperative bone density measurement device. Implant-supported rehabilitation is a predictable treatment option for tooth replacement whose success depends on the clinician's experience, the implant characteristics and location and patient-related factors. Among the latter, bone density is a determinant for the achievement of primary implant stability and, eventually, for implant success. The ability to measure bone density at the placement site before implant insertion could be important in the clinical setting. A patient complaining of masticatory impairment was presented with a plan calling for extraction of all her compromised teeth, followed by implant rehabilitation. A week before surgery, she underwent CT examination, and the bone density on the CT scans was measured. When the implant osteotomies were created, the bone density was again measured with a micromotor endowed with an instantaneous torque-measuring system. The implant placement protocols were adapted for each implant, according to the intraoperative measurements, and the patient was rehabilitated following an all-on-four immediate loading protocol. The bone density device provided valuable information beyond that obtained from CT scans, allowing for site-specific, intraoperative assessment of bone density immediately before implant placement and an estimation of primary stability just after implant insertion. Measuring jaw-bone density could help clinicians to select implant-placement protocols and loading strategies based on site-specific bone features.

  11. Oral Pyogenic Granuloma Associated With a Dental Implant Treated With an Er:YAG Laser: A Case Report.

    PubMed

    Kaya, Alper; Ugurlu, Faysal; Basel, Bilal; Sener, Cem B

    2015-12-01

    A pyogenic granuloma is a tumorlike proliferation that occurs slightly more often in females, frequently involving the gingiva in the maxillary region. Clinically, it presents as a sessile or pedunculated exophytic mass with a smooth or lobulated surface, which tends to bleed easily. Its color can range from pink to dark red. The most common treatment is surgical excision. This case report presents a pyogenic granuloma that formed around an implant 7 years after its insertion. Pyogenic granulomas associated with dental implants are extremely rare; this is the fourth reported case and the first case of pyogenic granuloma to be treated with an Er:YAG laser.

  12. The edentulous mandible opposed by natural maxillary teeth: a report of six cases treated with implant-retained prostheses.

    PubMed

    Clark, R K; Comfort, M B

    1994-01-01

    Dental restoration of the edentulous mandible opposing natural maxillary teeth is often associated with a number of problems, particularly in the occlusion, and an accelerated rate of alveolar bone resorption in the edentulous mandible resulting from occlusal loading. The advent of osseointegrated implants would seem to provide a new means of treating these cases. Accordingly, the cases of six patients for whom either fixed partial dentures or over-dentures supported by Brånemark implants were provided, are reviewed. Three of the mandibles were normal and three had bone grafts. Results so far indicate that this is a viable alternative for treating such cases.

  13. Surgical management of fibrotic encapsulation of the fluocinolone acetonide implant in CAPN5-associated proliferative vitreoretinopathy

    PubMed Central

    Tlucek, Paul S; Folk, James C; Sobol, Warren M; Mahajan, Vinit B

    2013-01-01

    Objective To review fibrosis of fluocinolone acetonide (FA) implants in subjects with CAPN5 autosomal dominant neovascular inflammatory vitreoretinopathy (ADNIV). Methods A retrospective case series was assembled from ADNIV patients in which there was fibrotic encapsulation of a fluocinolone acetonide implant. CAPN5 genotypes and surgical repair techniques were reviewed. Results Two eyes of two ADNIV patients developed a fibrotic capsule over the fluocinolone acetonide implant. Both patients had Stage IV disease. Patient A had a c.731T > C mutation in the CAPN5 gene and patient B had a c.728G > T mutation. The fibrotic membrane was surgically excised and the implant function was restored. Conclusion The exuberant fibrotic response in later stages of ADNIV may be resistant to local immunosuppression with steroids. Surgical excision of fibrotic membranes over FA implants can reestablish local steroid delivery in cases of severe proliferative vitreoretinopathy. PMID:23785231

  14. Surgical management of fibrotic encapsulation of the fluocinolone acetonide implant in CAPN5-associated proliferative vitreoretinopathy.

    PubMed

    Tlucek, Paul S; Folk, James C; Sobol, Warren M; Mahajan, Vinit B

    2013-01-01

    To review fibrosis of fluocinolone acetonide (FA) implants in subjects with CAPN5 autosomal dominant neovascular inflammatory vitreoretinopathy (ADNIV). A retrospective case series was assembled from ADNIV patients in which there was fibrotic encapsulation of a fluocinolone acetonide implant. CAPN5 genotypes and surgical repair techniques were reviewed. Two eyes of two ADNIV patients developed a fibrotic capsule over the fluocinolone acetonide implant. Both patients had Stage IV disease. Patient A had a c.731T > C mutation in the CAPN5 gene and patient B had a c.728G > T mutation. The fibrotic membrane was surgically excised and the implant function was restored. The exuberant fibrotic response in later stages of ADNIV may be resistant to local immunosuppression with steroids. Surgical excision of fibrotic membranes over FA implants can reestablish local steroid delivery in cases of severe proliferative vitreoretinopathy.

  15. Palliation double stenting for malignant biliary and duodenal obstruction

    PubMed Central

    ZHAO, LIANG; XU, HAITAO; ZHANG, YUBAO

    2016-01-01

    The surgical management of patients with malignant biliary and duodenal obstruction is complex. Tumor excision is no longer possible in the majority of patients with malignant obstructive jaundice and duodenal obstruction. The aim of the present study was to evaluate the effectiveness of intraluminal dual stent placement in malignant biliary and duodenal obstruction. In total, 20 patients with malignant obstructive jaundice and duodenal obstruction, including 6 with pancreatic carcinoma, 11 with cholangiocarcinoma, 1 with duodenal carcinoma and 2 with abdominal lymph node metastasis, were treated with intraluminal stent placement. Bile duct obstruction with late occurrence of duodenal obstruction was observed in 16 cases, and duodenal obstruction followed by a late occurrence of bile duct obstruction was observed in 3 cases, while, in 1 case, bile duct obstruction and duodenal obstruction occurred simultaneously. After X-ray fluoroscopy revealed obstruction in the bile duct and duodenum, stents were placed into the respective lumens. Percutaneous transhepatic placement was employed for the biliary stent, while the duodenal stent was placed perioraly. The clinical outcomes, including complications associated with the procedures and patency of the stents, were evaluated. The biliary and duodenal stents were successfully implanted in 18 patients and the technical success rate was 90% (18/20). A total of 39 stents were implanted in 20 patients. In 2 cases, duodenal stent placement failed following biliary stent placement. Duodenal obstruction remitted in 15 patients, and 1 patient succumbed to aspiration pneumonia 5 days after the procedure. No severe complications were observed in any other patient. The survival time of the 18 patients was 5–21 months (median, 9.6 months), and 6 of those patients survived for >12 months. The present study suggests that X-ray fluoroscopy-guided intraluminal stent implantation is an effective procedure for the treatment of malignant biliary and duodenal obstruction. PMID:26889267

  16. Optimization of spine surgery planning with 3D image templating tools

    NASA Astrophysics Data System (ADS)

    Augustine, Kurt E.; Huddleston, Paul M.; Holmes, David R., III; Shridharani, Shyam M.; Robb, Richard A.

    2008-03-01

    The current standard of care for patients with spinal disorders involves a thorough clinical history, physical exam, and imaging studies. Simple radiographs provide a valuable assessment but prove inadequate for surgery planning because of the complex 3-dimensional anatomy of the spinal column and the close proximity of the neural elements, large blood vessels, and viscera. Currently, clinicians still use primitive techniques such as paper cutouts, pencils, and markers in an attempt to analyze and plan surgical procedures. 3D imaging studies are routinely ordered prior to spine surgeries but are currently limited to generating simple, linear and angular measurements from 2D views orthogonal to the central axis of the patient. Complex spinal corrections require more accurate and precise calculation of 3D parameters such as oblique lengths, angles, levers, and pivot points within individual vertebra. We have developed a clinician friendly spine surgery planning tool which incorporates rapid oblique reformatting of each individual vertebra, followed by interactive templating for 3D placement of implants. The template placement is guided by the simultaneous representation of multiple 2D section views from reformatted orthogonal views and a 3D rendering of individual or multiple vertebrae enabling superimposition of virtual implants. These tools run efficiently on desktop PCs typically found in clinician offices or workrooms. A preliminary study conducted with Mayo Clinic spine surgeons using several actual cases suggests significantly improved accuracy of pre-operative measurements and implant localization, which is expected to increase spinal procedure efficiency and safety, and reduce time and cost of the operation.

  17. Evaluation of the success and complication rates of self-drilling orthodontic mini-implants.

    PubMed

    Gurdan, Z; Szalma, J

    2018-05-01

    Orthodontic mini-implants are important devices for successful anchorage management in orthodontics; however, the survival of these devices depends on several clinical factors. The aim of our study was to calculate the success and complication rates of orthodontic mini-implants. In this retrospective study, patients of our orthodontic department were enrolled, getting overall 59 orthodontic mini-implants during their orthodontic treatment in a 2-year period. Every patient had one or more of the 1.6 mm × 8 mm in size self-drilling mini-implants (Jeil Dual Top Anchor System, Jeil Medical Corp., Seoul, Korea). Screw loading was performed immediately after insertions, keeping tension forces under 150 g. Soft tissue and bone infections, implant mobility and screw loss, implant fracture, and neighboring tooth injury were registered. Relationships between variables were tested using the Chi-square test for statistical significance. The success rate of the orthodontic mini-implants was 89.8% in this study while the average loading period was 8.1 months. Soft-tissue infections varied between 6.3% and 33.3% of the cases while screw mobility varied between 3.1% and 20.8% of the cases regarding the anatomic localization. Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034). Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034) and screw mobility was found more frequently in case of intrusions than by extrusions (P = 0.036). The overall success rate of mini-implants was found acceptable in this study, however, screw mobility in the buccal fold showed a high incidence, suggesting the thorough consideration of the immediate loading by buccal mini-implants.

  18. Leakage current evaluation for pn junctions formed in DC and RF MeV ion implanted wells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yanagisawa, Yasunobu; Honda, Mitsuharu; Ogasawara, Makota

    1996-12-31

    The leakage current of pn junctions formed in DC and RF MeV implanted wells have been evaluated. There is no substantial difference in the leakage current levels between the continuous and pulsive beam implantations. However, the leakage current, so called diffusion current, for RF implanted wells is slightly higher than that for DC implanted wells on some condition. This suggests a possibility that relatively higher density of residual defects remains in the case of RIF implant.

  19. Usher syndrome and cochlear implantation.

    PubMed

    Loundon, Natalie; Marlin, Sandrine; Busquet, Denise; Denoyelle, Françoise; Roger, Gilles; Renaud, Francis; Garabedian, Erea Noel

    2003-03-01

    To evaluate the symptoms leading to diagnosis and the quality of rehabilitation after cochlear implantation in Usher syndrome. Retrospective cohort study. ENT department of a tertiary referral hospital. Among 210 patients given an implantation in the Ear, Nose, and Throat department, 185 were congenitally deaf and 13 had Usher syndrome (7.0%). Five had a family history of Usher, and eight were sporadic cases. Eleven cases were Usher type I, one was Usher type III, and one was not classified. The age at implantation ranged from 18 months to 44 years (mean, 6 years 1 month). The mean follow-up was 52 months (range, 9 months to 9 years). All patients had audiophonological and clinical examination, computed tomography scan of the temporal bones, ophthalmologic examination with fundoscopy, and an electroretinogram. Cerebral magnetic resonance imaging and vestibular examination were performed in 9 of 13 and 10 of 13 cases, respectively. Logopedic outcome measured preimplant and postimplant closed- and open-set word recognition and oral expression at follow-up. The most frequent initial sign of Usher syndrome was delayed walking, with a mean age of 20 months. Among the 172 other congenitally deaf children with implants, when deafness was not associated with other neurologic disorders, the mean age at walking was 14 months (p < 0.001). The fundoscopy was always abnormal after the age of 5 years, and the electroretinogram was abnormal in all cases. Vestibular function was abnormal in all but one case (nonclassified). The computed tomography scan and the magnetic resonance imaging were always normal. Logopedic results with cochlear implants showed good perception skills in all but one case. The best perceptive results were obtained in children implanted before the age of 9 years. Oral language had significantly progressed in 9 of 13 at follow-up. There was no relation between the visual acuity and the logopedic results. The earliest clinical sign associated with deafness evoking Usher syndrome is late walking. The electroretinogram is the only reliable examination to enable the diagnosis. When severe profound deafness is associated with late walking, the electroretinogram should be systematically proposed. Logopedic results are linked to precocity of implantation, and early Usher's diagnosis contributes to optimize speech therapy.

  20. Iritis, glaucoma and corneal decompensation associated with BrightOcular cosmetic iris implant.

    PubMed

    Mansour, Ahmad M; Ahmed, Iqbal Ike K; Eadie, Brennan; Chelala, Elias; Saade, Joanna S; Slade, Stephen G; Mearza, Ali A; Parmar, Dipak; Ghabra, Marwan; Luk, Sheila; Kelly, Alla; Kaufman, Stephen C

    2016-08-01

    NewColorIris cosmetic iris implants have a record of high ocular morbidity and are no longer in use. Newer generation of iris implants, BrightOcular, have patented posterior grooves in order to decrease iris touch and facilitate aqueous flow around the implant. However, little is known about their safety despite their implantations in 10 countries. Collaborative case series of patients who had bilateral implantation of cosmetic iris implants solely for cosmetic reasons. 12 cases were collected being distributed as Caucasian (10) and Asian (2), women (11) and man (1) and with a mean age of 32 years. Ocular manifestations were present in 11 subjects and included anterior uveitis (10 of 12; 83.3%), glaucoma (7 of 12; 58.3%) and corneal decompensation (6 of 12; 50%). Visual acuity was normal in seven, decreased in five with two having visual recovery following explantation of the implant. Glaucoma could not be controlled medically in two patients. Cosmetic iris implants carry the risk of ocular damage when implanted in the anterior chamber of normal phakic eyes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Group Distal Movement of Teeth using Micro-Screw-Implant Anchorage-A Case Report.

    PubMed

    Kalarickal, Biju

    2014-05-01

    This case report describes a case of orthodontic tooth movement of a 29-year-old female patient utilizing maxillary posterior edentulous area. Micro-implants were placed at buccal edentulous spaces and inter-radicular space for retraction of entire maxillary dentition. An overjet reduction of 8mm and good posterior occlusion were achieved.

  2. Periapical implant lesion: A systematic review

    PubMed Central

    Blaya-Tárraga, Juan-Antonio; Cervera-Ballester, Juan; Peñarrocha-Oltra, David; Peñarrocha-Diago, Miguel

    2017-01-01

    Background The aim of this study was to systematically review the evidence for periapical implant lesion, which makes a patient more susceptible to the periapical lesion, frequency, symptoms, signs (including radiological findings) and possible treatment options. Material and Methods A systematic literature review and analysis of publications included in PubMed, Embase and Cochrane; articles published until March 2016; with a populations, exposures and outcomes (PEO) search strategy was performed, focused on the issue: “In patients with periapical lesion to the implant during the osseointegration, what symptoms, signs, and changes in complementary examination manifested, for according to that stage, be intervened with the appropriate approach?”. The set criteria for inclusion were peer-reviewed articles. Results From a total of 212 papers identified, 36 studies were included in this systematic review, with 15461 implants evaluated and 183 periapical implant lesions. Which 8 papers included more than 5 cases and 28 included equal or less than 5 cases. Analysis of the papers revealed that periapical implant lesion is classified according to evolution stages into acute (non-suppurated and suppurated) and subacute (or suppurated-fistulized). In the acute stage and in the subacute if there is no loss of implant stability, the correct treatment approach is implant periapical surgery. In the subacute stage associated with implant mobility the implant must be removed. Conclusions Evidence on the subject is very limited, there are few studies with small sample, without homogeneity of criteria for diagnosing the disease and without design of scientific evidence. Currently etiology lacks consensus. The early diagnosis of periapical implant periapical lesions during the osseointegration phase and early treatment, will lead to a higher survival rate of implants treated, hence preventing the need for implant extraction. Key words:Apical peri-implantitis, retrograde peri-implantitis, inflammatory peri-implantitis lesion. PMID:29053646

  3. Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series

    PubMed Central

    Gay-Escoda, Cosme; Pérez-Álvarez, Débora; Camps-Font, Octavi

    2016-01-01

    Background The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. Material and Methods A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and surgical complications. Additionally, the patients were assessed for implant survival and success rates and for the prevalence of peri-implant diseases. A descriptive statistical analysis of the data was performed. Results Nine participants (57 implants) were included. The patients’ median age was 42 years (IQR=13.5 years). The implant survival and success rates were 98.3% and 68.4%, respectively, with a mean follow-up of 77.5 months (SD=16.1 months). The patient-based prevalence of peri-implant mucositis and peri-implantitis were 22.2% and 44.4% respectively at the last appointment. Patients that attended regular periodontal maintenance visits had significantly less mean bone loss than non-compliant patients (1.3 mm and 3.9 mm respectively). Conclusions Oral rehabilitation with dental implants in HIV-positive patients seems to provide satisfactory results. In order to reduce the considerably high prevalence of peri-implant diseases, strict maintenance programmes must be implemented. Key words:HIV infection, dental implants, oral implantology, complications, peri-implantitis, peri-implant diseases. PMID:26946205

  4. Tailoring Selective Laser Melting Process Parameters for NiTi Implants

    NASA Astrophysics Data System (ADS)

    Bormann, Therese; Schumacher, Ralf; Müller, Bert; Mertmann, Matthias; de Wild, Michael

    2012-12-01

    Complex-shaped NiTi constructions become more and more essential for biomedical applications especially for dental or cranio-maxillofacial implants. The additive manufacturing method of selective laser melting allows realizing complex-shaped elements with predefined porosity and three-dimensional micro-architecture directly out of the design data. We demonstrate that the intentional modification of the applied energy during the SLM-process allows tailoring the transformation temperatures of NiTi entities within the entire construction. Differential scanning calorimetry, x-ray diffraction, and metallographic analysis were employed for the thermal and structural characterizations. In particular, the phase transformation temperatures, the related crystallographic phases, and the formed microstructures of SLM constructions were determined for a series of SLM-processing parameters. The SLM-NiTi exhibits pseudoelastic behavior. In this manner, the properties of NiTi implants can be tailored to build smart implants with pre-defined micro-architecture and advanced performance.

  5. A three-dimensional finite element analysis of a passive and friction fit implant abutment interface and the influence of occlusal table dimension on the stress distribution pattern on the implant and surrounding bone

    PubMed Central

    Sarfaraz, Hasan; Paulose, Anoopa; Shenoy, K. Kamalakanth; Hussain, Akhter

    2015-01-01

    Aims: The aim of the study was to evaluate the stress distribution pattern in the implant and the surrounding bone for a passive and a friction fit implant abutment interface and to analyze the influence of occlusal table dimension on the stress generated. Materials and Methods: CAD models of two different types of implant abutment connections, the passive fit or the slip-fit represented by the Nobel Replace Tri-lobe connection and the friction fit or active fit represented by the Nobel active conical connection were made. The stress distribution pattern was studied at different occlusal dimension. Six models were constructed in PRO-ENGINEER 05 of the two implant abutment connection for three different occlusal dimensions each. The implant and abutment complex was placed in cortical and cancellous bone modeled using a computed tomography scan. This complex was subjected to a force of 100 N in the axial and oblique direction. The amount of stress and the pattern of stress generated were recorded on a color scale using ANSYS 13 software. Results: The results showed that overall maximum Von Misses stress on the bone is significantly less for friction fit than the passive fit in any loading conditions stresses on the implant were significantly higher for the friction fit than the passive fit. The narrow occlusal table models generated the least amount of stress on the implant abutment interface. Conclusion: It can thus be concluded that the conical connection distributes more stress to the implant body and dissipates less stress to the surrounding bone. A narrow occlusal table considerably reduces the occlusal overload. PMID:26929518

  6. Aviation accident risk for airmen with aphakia and artificial lens implants.

    DOT National Transportation Integrated Search

    1993-06-01

    Airmen with aphakia and intraocular (IOL) implants who on a case-by-case basis, may obtain a waiver for a medical certificate have been previously associated with higher aviation accident rates when compared to the total civil airman population. This...

  7. Combined piezosurgery and selective distraction osteogenesis to correct malpositioned implants: a case report.

    PubMed

    Parma-Benfenati, Stefano; Maino, Giuliano B

    2015-01-01

    This case report shows the combined use of piezosurgical and orthodontic procedures to successfully relocate two severely malpositioned implants in the anterior maxilla by moving them separately, with the objective of attaining functional prosthetic restoration and acceptable esthetics.

  8. Malfunction of subpectorally implanted cardiac resynchronization therapy defibrillators due to weakened header bond.

    PubMed

    Hayat, Sajad A; Kojodjojo, Pipin; Mason, Anthony; Benfield, Ann; Wright, Ian; Whinnett, Zachary; Lim, Phang Boon; Davies, D Wyn; Lefroy, David; Peters, Nicholas S; Kanagaratnam, Prapa

    2013-03-01

    Implantable cardioverter defibrillator (ICD) implantation has increased significantly over the last 10 years. Concerns about the safety and reliability of ICD systems have been raised, with premature lead failure and battery malfunctions accounting for the majority of reported adverse events. We describe the unique mode of presentation, diagnosis, and management of cardiac resynchronization therapy defibrillators (CRT-D) malfunctions that were caused by weakened bonding between the generator and header. Between June 2008 and December 2009, 22 Teligen™ ICDs and 24 Cognis™ CRT-Ds were implanted subpectorally at our institution, until a product advisory was issued. Of 24 Cognis™ CRT-D implants, 3 patients presented with CRT-D malfunctions. All our cases presented with initially intermittent and then persisting increases in shock lead impedance, associated with nonphysiological noise in the shock electrogram channels. These issues were rectified by generator change. Postexplant laboratory analysis confirmed inadequate bonding between device header and titanium casing in all cases, resulting in loosening and rocking of the header followed by fatigue-induced fracture of the shock circuitry. Weakened bonding between the header and generator casing of subpectorally implanted CRT-Ds can result in fractures and malfunction of the HV circuit. Physicians monitoring patients with devices affected by the product advisory should remain vigilant in order to diagnose and manage similar device malfunction expediently. © 2012 Wiley Periodicals, Inc.

  9. No allergic reaction after TKA in a chrome-cobalt-nickel-sensitive patient: case report and review of the literature.

    PubMed

    Thienpont, Emmanuel; Berger, Yorick

    2013-03-01

    Hypersensitivity to metallic implants remains relatively unpredictable and poorly understood. Although 20-25 % of total joint arthroplasty patients develop metal sensitivity, only a few highly susceptible persons (<1 %) exhibit symptoms. We present a case report of a fifty-two-year-old woman with a preoperatively documented metal allergy who underwent bilateral total knee arthroplasty using a titanium-niobium-coated implant on one side and a chrome-cobalt implant on the other side because of a logistics problem. At 2-year follow-up, no clinical symptoms of allergy or loosening of the implant were observed. Level of evidence IV.

  10. Surgical Treatment of Implants Affected by Periimplantitis After 15 Years of Loading: A Case Report.

    PubMed

    Nícoli, Lélis Gustavo; Pigossi, Suzane Cristina; Marcantonio, Cláudio; Leal Zandim-Barcelos, Daniela; Marcantonio, Elcio

    2016-04-01

    The aim of this case report is to describe the surgical treatment of 2 implants affected by periimplantitis after 15 years of loading. The treatment included mechanical and chemical decontamination with topical application of tetracycline associated with a regenerative approach. Both defects were filled with particulate autogenous bone from tuber and covered with resorbable collagen membrane. The follow-up of 30 and 13 months of the implants 24 and 14, respectively, showed an absence of clinical signs of periimplant inflammation and near-complete bone regeneration. The therapy approach was effective in eliminating periimplant inflammation and promoting bone gain around the implants.

  11. Complications Associated With the Use of Recombinant Human Bone Morphogenic Protein-2 in Ridge Augmentation: A Case Report.

    PubMed

    Dragonas, Panagiotis; Palin, Charles; Khan, Saba; Gajendrareddy, Praveen K; Weiner, Whitney D

    2017-10-01

    This case report aims to describe in detail a complication associated with resorption of regenerated bone following implant placement and ridge augmentation using recombinant human bone morphogenic protein-2 (rhBMP-2) in combination with allograft and xenograft. Bilateral maxillary sinus and ridge augmentation procedures were completed using rhBMP-2 combined with allograft and xenograft. Five months later, significant bone augmentation was achieved, which allowed for the placement of 4 implants. Upon stage 2 surgery, significant dehiscence was noted in all implants. Treatment steps to address this complication included implant removal, guided bone regeneration with xenograft only, and placement of new implants followed by soft-tissue grafting. At the time of publication, this patient is status 1½ years post case completion with maintenance of therapy outcomes. Off-label use of rhBMP-2 has gained significant acceptance in implant dentistry. However, there is limited evidence regarding the bone maturation process when rhBMP-2 is combined with other biomaterials. More research may be needed regarding the timing and process of bone healing in the presence of rhBMP-2, in an effort to avoid surgical complications.

  12. Guided Immediate Implant Placement with Wound Closure by Computer-Aided Design/Computer-Assisted Manufacture Sealing Socket Abutment: Case Report.

    PubMed

    Finelle, Gary; Lee, Sang J

    Digital technology has been widely used in the field of implant dentistry. From a surgical standpoint, computer-guided surgery can be utilized to enhance primary implant stability and to improve the precision of implant placement. From a prosthetic standpoint, computer-aided design/computer-assisted manufacture (CAD/CAM) technology has brought about various restorative options, including the fabrication of customized abutments through a virtual design based on computer-guided surgical planning. This case report describes a novel technique combining the use of a three-dimensional (3D) printed surgical template for the immediate placement of an implant, with CAD/CAM technology to optimize hard and soft tissue healing after bone grafting with the use of a socket sealing abutment.

  13. A Case of Orbital Abscess following Porous Orbital Implant Infection

    PubMed Central

    Hong, Seung Woo; Paik, Ji-Sun; Kim, So-Youl

    2006-01-01

    Purpose We present a case of orbital abscess following porous orbital implant infection in a 73-year-old woman with rheumatoid arthritis. Methods Just one month after a seemingly uncomplicated enucleation and porous polyethylene (Medpor®) orbital implant surgery, implant exposure developed with profuse pus discharge. The patient was unresponsive to implant removal and MRI confirmed the presence of an orbital pus pocket. Despite extirpation of the four rectus muscles, inflammatory granulation debridement and abscess drainage, another new pus pocket developed. Results After partial orbital exenteration, the wound finally healed well without any additional abscess formation. Conclusions A patient who has risk factors for delayed wound healing must be examined thoroughly and extreme care such as exenteration must be taken if there is persistent infection. PMID:17302210

  14. Device-based local delivery of siRNA against mammalian target of rapamycin (mTOR) in a murine subcutaneous implant model to inhibit fibrous encapsulation

    PubMed Central

    Takahashi, Hironobu; Wang, Yuwei; Grainger, David W.

    2010-01-01

    Fibrous encapsulation of surgically implant devices is associated with elevated proliferation and activation of fibroblasts in tissues surrounding these implants, frequently causing foreign body complications. Here we test the hypothesis that inhibition of the expression of mammalian target of rapamycin (mTOR) in fibroblasts can mitigate the soft tissue implant foreign body response by suppressing fibrotic responses around implants. In this study, mTOR was knocked down using small interfering RNA conjugated with branched cationic polyethylenimine (bPEI) in fibroblastic lineage cells in serum-based cell culture as shown by both gene and protein analysis. This mTOR knockdown led to an inhibition in fibroblast proliferation by 70% and simultaneous down-regulation in the expression of type I collagen in fibroblasts in vitro. These siRNA/bPEI complexes were released from poly(ethylene glycol) (PEG)-based hydrogel coatings surrounding model polymer implants in a subcutaneous rodent model in vivo. No significant reduction in fibrous capsule thickness and mTOR expression in the foreign body capsules was observed. Observed siRNA inefficacy in this in vivo implant model was attributed to siRNA dosing limitations in the gel delivery system, and lack of targeting ability of the siRNA complex specifically to fibroblasts. While in vitro data supported mTOR knock-down in fibroblast cultures, in vivo siRNA delivery must be further improved to produce clinically relevant effects on fibrotic encapsulation around implants. PMID:20727922

  15. Histological analysis of soft and hard tissues in a periimplantitis lesion: a human case report.

    PubMed

    Jung, Soong-Ryong; Bashutski, Jill D; Jandali, Rami; Prasad, Hari; Rohrer, Michael; Wang, Hom-Lay

    2012-06-01

    Little is known regarding the histologic hard and soft tissue changes that occur in chronic periimplantitis situations in humans. It is critical to gain an understanding of all aspects of periimplantitis to develop appropriate therapeutic approaches. An 83-year-old African American man presented with a fractured implant affected by severe, chronic periimplantitis and surrounded by keratinized gingiva. A trephine biopsy of the implant and surrounding tissues was analyzed histologically. Histological analysis of the periimplantitis specimen revealed significant inflammatory infiltrate consisting predominantly of lymphocytes and plasma cells. In addition, epithelial migration and bone loss to the apical vent were noted. This case report documents a single case of periimplantitis that was left untreated for 7 years. The presence of significant keratinized tissue and a smooth surface implant failed to prevent fibrous encapsulation of the implant.

  16. Fixed and mobile-bearing total ankle prostheses: Effect on tibial bone strain.

    PubMed

    Terrier, Alexandre; Fernandes, Caroline Sieger; Guillemin, Maïka; Crevoisier, Xavier

    2017-10-01

    Total ankle replacement is associated to a high revision rate. To improve implant survival, the potential advantage of prostheses with fixed bearing compared to mobile bearing is unclear. The objective of this study was to test the hypothesis that fixed and mobile bearing prostheses are associated with different biomechanical quantities typically associated to implant failure. With a validated finite element model, we compared three cases: a prosthesis with a fixed bearing, a prosthesis with a mobile bearing in a centered position, and a prosthesis with mobile bearing in an eccentric position. Both prostheses were obtained from the same manufacturer. They were tested on seven tibias with maximum axial compression force during walking. We tested the hypothesis that there was a difference of bone strain, bone-implant interfacial stress, and bone support between the three cases. We also evaluated, for the three cases, the correlations between bone support, bone strain and bone-implant interfacial stress. There were no statistically significant differences between the three cases. Overall, bone support was mainly trabecular, and less effective in the posterior side. Bone strain and bone-implant interfacial stress were strongly correlated to bone support. Even if slight differences are observed between fixed and mobile bearing, it is not enough to put forward the superiority of one of these implants regarding their reaction to axial compression. When associated to the published clinical results, our study provides no argument to warn surgeons against the use of two-components fixed bearing implants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Cochlear Implantation After Partial or Subtotal Cochleoectomy for Intracochlear Schwannoma Removal-A Technical Report.

    PubMed

    Plontke, Stefan K; Kösling, Sabrina; Rahne, Torsten

    2018-03-01

    To describe the technique for surgical tumor removal, cochlear implant (CI) electrode placement and reconstruction of the surgical defect in patients with intracochlear schwannomas. Retrospective case review. Tertiary referral center. Ten patients (five men, five women, mean age 48 ± 12 yr) with profound or severe to profound hearing loss due to intralabyrinthine schwannomas with intracochlear location. Surgical tumor removal through extended round window approach, partial or subtotal cochleoectomy with or without labyrinthectomy and reconstruction of the surgical defect with cartilage, perichondrium or temporal muscle fascia, and bone pâté. Eight patients received a cochlear implant in the same procedure. Retrospective evaluation of clinical outcome including safety aspects (adverse events) and audiological performance at early follow up in cases of cochlear implantation. The tumor was successfully removed in all cases without macroscopic (operation microscope and endoscope) tumor remnants in the bony labyrinth apart from one case with initial transmodiolar growth. One patient needed revision surgery for labyrinthine fistula. At short-term follow up (3-month post-surgery), good hearing results with the cochlear implant were obtained in all but one patient with a word recognition score of 100% for numbers, and 64 ± 14% for monosyllables (at 65 dB SPL in quiet). Surgical tumor removal and cochlear implantation is a promising treatment strategy in the management of intralabyrinthine schwannoma with intracochlear location, further extending the indication range for cochlear implantation. It is, however, of importance to observe the long-term outcome in these patients and to address challenges like follow up with magnetic resonance imaging.

  18. Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures.

    PubMed

    Bernhart, Gunda; Koob, Andreas; Schmitter, Marc; Gabbert, Olaf; Stober, Thomas; Rammelsberg, Peter

    2012-08-01

    The objective of this retrospective study was to compare biological and technical complications of implant-supported and tooth-implant-supported double crown-retained dentures (DCRDs) with those of tooth-supported DCRDs. Sixty-three DCRDs were monitored. One study group included 16 prostheses with a combination of implants and natural teeth as double crowns (ti group), whereas in the second study group, 19 dentures were retained exclusively on implants (ii group); a third study group with 28 exclusively tooth-supported dentures served as controls (tt group). Tooth loss, implant failure, and technical complications (loss of retention of primary crown, abutment screw loosening, loss of facing, fracture of resin denture teeth and fracture of saddle resin) were analysed. During the observation period of 24 months, no implants or teeth were lost in the ti group and three technical complications were recorded. In the ii group, two implants were lost, two cases of peri-implantitis occurred and four technical complications were observed. In the tt group, two cases of tooth loss and seven technical complications were observed. At the time of the last examination, all prostheses of the ti group and the ii group were functional. Patients of these two study groups reported high satisfaction with both function and aesthetics with no significant difference between the two groups. Treatment with DCRDs showed comparable results in the three study groups. The 2-year results indicate that double crowns can be recommended for implant and combined tooth-implant-retained dentures.

  19. How does implant distribution affect 3D correction and bone-screw forces in thoracic adolescent idiopathic scoliosis spinal instrumentation?

    PubMed

    Le Navéaux, Franck; Larson, A Noelle; Labelle, Hubert; Wang, Xiaoyu; Aubin, Carl-Éric

    2016-11-01

    Optimal implant densities and configurations for thoracic spine instrumentation to treat adolescent idiopathic scoliosis remain unknown. The objective was to computationally assess the biomechanical effects of implant distribution on 3D curve correction and bone-implant forces. 3D patient-specific biomechanical spine models based on a multibody dynamic approach were created for 9 Lenke 1 patients who underwent posterior instrumentation (main thoracic Cobb: 43°-70°). For each case, a factorial design of experiments was used to generate 128 virtual implant configurations representative of existing implant patterns used in clinical practice. All instances except implant configuration were the same for each surgical scenario simulation. Simulation of the 128 implant configurations scenarios (mean implant density=1.32, range: 0.73-2) revealed differences of 2° to 10° in Cobb angle correction, 2° to 7° in thoracic kyphosis and 2° to 7° in apical vertebral rotation. The use of more implants, at the concave side only, was associated with higher Cobb angle correction (r=-0.41 to -0.90). Increased implant density was associated with higher apical vertebral rotation correction for seven cases (r=-0.20 to -0.48). It was also associated with higher bone-screw forces (r=0.22 to 0.64), with an average difference between the least and most constrained instrumentation constructs of 107N per implant at the end of simulated instrumentation. Low-density constructs, with implants mainly placed on the concave side, resulted in similar simulated curve correction as the higher-density patterns. Increasing the number of implants allows for only limited improvement of 3D correction and overconstrains the instrumentation construct, resulting in increased forces on the implants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Neural prostheses in clinical applications--trends from precision mechanics towards biomedical microsystems in neurological rehabilitation.

    PubMed

    Stieglitz, T; Schuettler, M; Koch, K P

    2004-04-01

    Neural prostheses partially restore body functions by technical nerve excitation after trauma or neurological diseases. External devices and implants have been developed since the early 1960s for many applications. Several systems have reached nowadays clinical practice: Cochlea implants help the deaf to hear, micturition is induced by bladder stimulators in paralyzed persons and deep brain stimulation helps patients with Parkinson's disease to participate in daily life again. So far, clinical neural prostheses are fabricated with means of precision mechanics. Since microsystem technology opens the opportunity to design and develop complex systems with a high number of electrodes to interface with the nervous systems, the opportunity for selective stimulation and complex implant scenarios seems to be feasible in the near future. The potentials and limitations with regard to biomedical microdevices are introduced and discussed in this paper. Target specifications are derived from existing implants and are discussed on selected applications that has been investigated in experimental research: a micromachined implant to interface a nerve stump with a sieve electrode, cuff electrodes with integrated electronics, and an epiretinal vision prosthesis.

  1. Passive film growth on titanium alloys: physicochemical and biologic considerations.

    PubMed

    Eliades, T

    1997-01-01

    The role of reactive oxygen derivatives (hydroxy peroxide, hydroxyl radical, and singlet oxygen) on the precipitation of inorganic and organic complexes onto the surface of titanium implant alloys is discussed in this review. In addition, the effect of possible implication of several biologic entities surrounding the implant on the implant-tissue interface constituents is described. Evidence from relevant studies suggests that local microenvironmental byproducts and factors associated with the inflammatory response resulting from the implant-induced tissue insult may enhance the expressivity of the inherent, clinically important property of titanium to form oxides. Growth of titanium oxide may be explained through several processes derived from biologic, thermodynamic, and electrochemical approaches. The models proposed to interpret this phenomenon are often contradictory, demonstrating inward or outward from the bulk material passive film growth, with increasing or self-limiting levels of oxide formation as a function of time. However, in vivo observations are consistent with aging-induced thickening of the complexes precipitated on the implant material surface. This review attempts to clarify several critical issues pertaining to passive film formation and kinetics on titanium-alloy surfaces.

  2. Osteochondritis Dessicans- Primary Fixation using Bioabsorbable Implants

    PubMed Central

    Galagali, Anand; Rao, Muralidhar

    2012-01-01

    Introduction: Osteochondritis dessicans (OCD) is a localized condition where a section of articular cartilage and underlying subchondral bone separate from the joint surface. It is important to diagnose unstable OCD early and fix the fragments primarily as the results of any surgical management at late presentations are guarded. Use of bioabsorbable implants for fixing OCD is recent and we report one such case in grade IV OCD. Case Report: We present a 14 year old girl who came with a history of acute pain, swelling, inability to bear weight on the right knee following a dance practice. MRI showed stage IV osteochondral fragment measuring 20x 8mm lying free. This was primarily fixed with bioabsorbable implants. 10 months follow up showed excellent clinical and functional results. Conclusion: This case highlights the advantages of early primary fixation whenever possible. By far, to our knowledge, this is the first case of successful treatment of stage IV OCD using bioabsorbable implants. PMID:27298854

  3. Peri-implant diseases and conditions: Consensus report of workgroup 4 of the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions.

    PubMed

    Berglundh, Tord; Armitage, Gary; Araujo, Mauricio G; Avila-Ortiz, Gustavo; Blanco, Juan; Camargo, Paulo M; Chen, Stephen; Cochran, David; Derks, Jan; Figuero, Elena; Hämmerle, Christoph H F; Heitz-Mayfield, Lisa J A; Huynh-Ba, Guy; Iacono, Vincent; Koo, Ki-Tae; Lambert, France; McCauley, Laurie; Quirynen, Marc; Renvert, Stefan; Salvi, Giovanni E; Schwarz, Frank; Tarnow, Dennis; Tomasi, Cristiano; Wang, Hom-Lay; Zitzmann, Nicola

    2018-06-01

    A classification for peri-implant diseases and conditions was presented. Focused questions on the characteristics of peri-implant health, peri-implant mucositis, peri-implantitis, and soft- and hard-tissue deficiencies were addressed. Peri-implant health is characterized by the absence of erythema, bleeding on probing, swelling, and suppuration. It is not possible to define a range of probing depths compatible with health; Peri-implant health can exist around implants with reduced bone support. The main clinical characteristic of peri-implant mucositis is bleeding on gentle probing. Erythema, swelling, and/or suppuration may also be present. An increase in probing depth is often observed in the presence of peri-implant mucositis due to swelling or decrease in probing resistance. There is strong evidence from animal and human experimental studies that plaque is the etiological factor for peri-implant mucositis. Peri-implantitis is a plaque-associated pathological condition occurring in tissues around dental implants, characterized by inflammation in the peri-implant mucosa and subsequent progressive loss of supporting bone. Peri-implantitis sites exhibit clinical signs of inflammation, bleeding on probing, and/or suppuration, increased probing depths and/or recession of the mucosal margin in addition to radiographic bone loss. The evidence is equivocal regarding the effect of keratinized mucosa on the long-term health of the peri-implant tissue. It appears, however, that keratinized mucosa may have advantages regarding patient comfort and ease of plaque removal. Case definitions in day-to-day clinical practice and in epidemiological or disease-surveillance studies for peri-implant health, peri-implant mucositis, and peri-implantitis were introduced. The proposed case definitions should be viewed within the context that there is no generic implant and that there are numerous implant designs with different surface characteristics, surgical and loading protocols. It is recommended that the clinician obtain baseline radiographic and probing measurements following the completion of the implant-supported prosthesis. © 2018 American Academy of Periodontology and European Federation of Periodontology.

  4. Sliding mechanics with microscrew implant anchorage.

    PubMed

    Park, Hyo-Sang; Kwon, Tae-Geon

    2004-10-01

    Three cases are illustrated. One was treated with maxillary microscrew implants, another with mandibular microscrew implants, and the third with both maxillary and mandibular microscrew implants. With the maxillary microscrew implants, the maxillary anterior teeth were retracted bodily with a slight intrusion and all the premolar extraction space was closed without loss of anchorage. Furthermore, the maxillary posterior teeth showed distal movement. The mandibular microscrew implants controlled the vertical position of the mandibular posterior teeth and played an important role in improving the facial profile. The efficacy of sliding mechanics with microscrew implant anchorage on the treatment of skeletal Class II malocclusion is also discussed.

  5. Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients.

    PubMed

    Lange, Rüdiger; Bleiziffer, Sabine; Piazza, Nicolo; Mazzitelli, Domenico; Hutter, Andrea; Tassani-Prell, Peter; Laborde, Jean-Claude; Bauernschmitt, Robert

    2011-11-01

    Trans-catheter aortic valve implantation (TAVI) technology is rapidly evolving, with 412 procedures having been performed at our institution. Herein, we report a complete, prospective analysis of complications occurring during transvascular and trans-apical implantations with two different prostheses. Between June 2007 and June 2010, 412 patients (258 female, mean age 80.3±7.2 years, logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) 20.2%±13.0%) underwent TAVI through either a retrograde (n=252 transfemoral, n=28 transaxillary, and n=5 transaortic) or antegrade (n=127 trans-apical) approach at our institution. The trans-apical access was chosen only in cases where transvascular implantation was not possible. As many as 283 CoreValve and 129 Edwards Sapien prostheses were implanted. Thirty-day survival was 90.9%. Vascular complications occurred in 42 patients (10.2%). In four patients, lethal aortic root (n=3) or abdominal (n=1) aortic rupture occurred. Pericardial effusion developed in 53 patients (12.8%), which resulted in cardiac tamponade in 12 patients (2.9%). Twenty-three patients (5.6%) with valve malplacement were treated interventionally. In five patients (1.2%), emergency institution of cardiopulmonary bypass was required during the procedure for temporary support; all patients survived. Seventeen patients underwent re-intervention on the catheter valve (4.1%). With growing experience, complications with TAVI may be avoided by proper patient selection and skillful management. Other complications, when they occur, require a specific treatment algorithm to avoid delay in decision making. A considerable number of complications after TAVI require surgical treatment. Therefore, the ideal environment for TAVI procedures is a hybrid operating room, where a multidisciplinary team of surgeons, cardiologists, and anesthesiologists is best fitted to meet the current needs associated with TAVI technology. A reduction in complications was seen after 300 cases. This finding attests to the complexity of the procedure in addition to the experience required to reduce the incidence of complications. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  6. Effect of dose and size on defect engineering in carbon cluster implanted silicon wafers

    NASA Astrophysics Data System (ADS)

    Okuyama, Ryosuke; Masada, Ayumi; Shigematsu, Satoshi; Kadono, Takeshi; Hirose, Ryo; Koga, Yoshihiro; Okuda, Hidehiko; Kurita, Kazunari

    2018-01-01

    Carbon-cluster-ion-implanted defects were investigated by high-resolution cross-sectional transmission electron microscopy toward achieving high-performance CMOS image sensors. We revealed that implantation damage formation in the silicon wafer bulk significantly differs between carbon-cluster and monomer ions after implantation. After epitaxial growth, small and large defects were observed in the implanted region of carbon clusters. The electron diffraction pattern of both small and large defects exhibits that from bulk crystalline silicon in the implanted region. On the one hand, we assumed that the silicon carbide structure was not formed in the implanted region, and small defects formed because of the complex of carbon and interstitial silicon. On the other hand, large defects were hypothesized to originate from the recrystallization of the amorphous layer formed by high-dose carbon-cluster implantation. These defects are considered to contribute to the powerful gettering capability required for high-performance CMOS image sensors.

  7. An in vivo assessment of the effects of using different implant abutment occluding materials on implant microleakage and the peri-implant microbiome

    NASA Astrophysics Data System (ADS)

    Rubino, Caroline

    Microleakage may be a factor in the progression of peri-implant pathology. Microleakage in implant dentistry refers to the passage of bacteria, fluids, molecules or ions between the abutment-implant interface to and from the surrounding periodontal tissues. This creates a zone of inflammation and reservoir of bacteria at the implant-abutment interface. Bone loss typically occurs within the first year of abutment connection and then stabilizes. It has not yet been definitively proven that the occurrence of microleakage cannot contribute to future bone loss or impede the treatment of peri-implant disease. Therefore, strategies to reduce or eliminate microleakage are sought out. Recent evidence demonstrates that the type of implant abutment channel occluding material can affect the amount of microleakage in an in vitro study environment. Thus, we hypothesize that different abutment screw channel occluding materials will affect the amount of observed microleakage, vis-a-vis the correlation between the microflora found on the abutment screw channel occluding material those found in the peri-implant sulcus. Additional objectives include confirming the presence of microleakage in vivo and assessing any impact that different abutment screw channel occluding materials may have on the peri-implant microbiome. Finally, the present study provides an opportunity to further characterize the peri-implant microbiome. Eight fully edentulous patients restored with at dental implants supporting screw-retained fixed hybrid prostheses were included in the study. At the initial appointment (T1), the prostheses were removed and the implants and prostheses were cleaned. The prostheses were then inserted with polytetrafluoroethylene tape (PTFE, TeflonRTM), cotton, polyvinyl siloxane (PVS), or synthetic foam as the implant abutment channel occluding material and sealed over with composite resin. About six months later (T2), the prostheses were removed and the materials collected. Paper points were used to sample the peri-implant sulcus bacteria. All samples were then submitted to DNA purification, polymerase chain reaction (PCR), and sequencing protocols to assess relative numbers of bacterial species. Periodontal parameters were collected at both time points. Overall, our findings support several conclusions. Different implant abutment channel occluding materials appear to have no effect on the amount of observed microleakage and the peri-implant microbiome. Evidence for microleakage was found in the present study, corroborating existing in vivo evidence. Finally, we gained several insights regarding the peri implant microbiome. Of note, the peri-implant microbiome is well described by the classical periodontal microbial complexes, but a large portion consists of bacteria not previously classified into the microbial complexes.

  8. Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series.

    PubMed

    Gay-Escoda, C; Pérez-Álvarez, D; Camps-Font, O; Figueiredo, R

    2016-05-01

    The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and surgical complications. Additionally, the patients were assessed for implant survival and success rates and for the prevalence of peri-implant diseases. A descriptive statistical analysis of the data was performed. Nine participants (57 implants) were included. The patients' median age was 42 years (IQR=13.5 years). The implant survival and success rates were 98.3% and 68.4%, respectively, with a mean follow-up of 77.5 months (SD=16.1 months). The patient-based prevalence of peri-implant mucositis and peri-implantitis were 22.2% and 44.4% respectively at the last appointment. Patients that attended regular periodontal maintenance visits had significantly less mean bone loss than non-compliant patients (1.3 mm and 3.9 mm respectively). Oral rehabilitation with dental implants in HIV-positive patients seems to provide satisfactory results. In order to reduce the considerably high prevalence of peri-implant diseases, strict maintenance programmes must be implemented.

  9. Successful weaning of a left ventricular assist device implanted for ischemic heart failure.

    PubMed

    Beurtheret, Sylvain; Mordant, Pierre; Pavie, Alain; Leprince, Pascal

    2010-10-01

    We report the case of a patient stabilized under extra-corporeal membrane oxygenation after a refractory cardiogenic shock following myocardial infarction. Persistent left ventricular failure required secondary implantation of the left ventricular assist device (LVAD) HeartMate II. LVAD succeeded in the gradual recovery of myocardial contractility, allowing weaning of the device five months after implantation. Simultaneously, the patient beneficiated from coronary revascularization and resumed normal activity. This case emphasizes potential late recoveries after myocardial infarction complicated by left ventricular failure.

  10. Consciousness recovery induced by intrathecal baclofen administration after subarachnoid hemorrhage -two case reports-.

    PubMed

    Oyama, Hirofumi; Kito, Akira; Maki, Hideki; Hattori, Kenichi; Tanahashi, Kuniaki

    2010-01-01

    Two patients with subarachnoid hemorrhage recovered consciousness after intrathecal baclofen administration using an implanted intrathecal baclofen pump delivering 50 microg per day using a simple infusion mode. Intrathecal baclofen resulted in significant reduction of spasticity 3 months after the implantation. Case 1 was reduced to a completely bedridden state with spasticity and could slightly move her fingers following commands. However, the patient could eat food and wash her face with minimal assistance at 3 months after the implantation, and could stand up in the parallel bars with assistance and speak several words at 8 months. Case 2 was in a completely bedridden state at 10 months after onset and could neither drink water nor follow instructions. However, the patient became oriented and could eat by herself within 3 to 4 weeks of implantation. She could walk with a cane and use the stairs with minimal assistance at 2 and 3 months after implantation. The patient could speak fluently within 6 months of implantation. Flatulence and dysuria happened during the screening test, but these symptoms were not repeated after implantation of a pump-catheter-system and continuous intrathecal baclofen infusion. Continuous intrathecal baclofen infusion caused both improvement in muscle tone and spasms and consciousness recovery from the vegetative state. This therapy is a strong candidate treatment for patients with spasticity and consciousness disturbance.

  11. Magnet and Semi Precision Attachment in an Implant Retained Partial Denture for the Rehabilitation of an Irradiated Marginal Mandibulectomy Patient: A Case Report

    PubMed Central

    Guttal, Satyabodh Shesharaj; Kulkarni, Sudhindra S; Kudva, Adarsh; Thakur, Srinath

    2015-01-01

    Surgical treatment of malignancies in the oral cavity (mandible, tongue, floor of the mouth, alveolus, buccal sulcus) often results in an unfavourable anatomic condition for prosthodontic rehabilitation. Hence, maxillofacial prosthetic rehabilitation becomes a mightier task when resection is accompanied by radiation therapy. In selected cases, implant therapy comes to rescue. The following report throws light on the case of prosthetic rehabilitation of a patient who underwent right marginal mandibulectomy and right partial glossectomy, with the aid of a single implant, semi precision attachment and magnet supported partial denture. PMID:26501028

  12. Custom Titanium Ridge Augmentation Matrix (CTRAM): A Case Report.

    PubMed

    Connors, Christopher A; Liacouras, Peter C; Grant, Gerald T

    2016-01-01

    This is a case report of a custom titanium ridge augmentation matrix (CTRAM). Using cone beam computed tomography (CBCT), a custom titanium space-maintaining device was developed. Alveolar ridges were virtually augmented, a matrix was virtually designed, and the CTRAM was additively manufactured with titanium (Ti6Al4V). Two cases are presented that resulted in sufficient increased horizontal bone volume with successful dental implant placement. The CTRAM design allows for preoperative planning for increasing alveolar ridge dimensions to support dental implants, reduces surgical time, and prevents the need for a second surgical site to gain sufficient alveolar ridge bone volume for dental implant therapy.

  13. Starflo glaucoma implant: early experience in Hungary

    PubMed Central

    István, Cseke; Péter, Vámosi; Mária, Bausz

    2016-01-01

    Aim: To present the early experience with the implantation technique, safety and efficiency of STARflo™ device for open angle glaucoma (OAG). Methods: referring intra- and postoperative clinical experience with a series of seven cases in three glaucoma centers in Hungary. Results: No intraoperative complications were observed. Postoperative inflammatory signs disappeared rapidly. The mean IOP reduction was from 27,6 ± 5,0 mmHg to 18,9±3,4 mmHg (32% reduction/ patient) at six months postoperatively. Conclusion: STARflo™ implant was safe and (except for one case with neovascular glaucoma) effective in our cases. The learning curve for experienced anterior segment surgeons was short. PMID:27220226

  14. Surgical Management of Iatrogenic Pigment Dispersion Glaucoma.

    PubMed

    Mierlo, Camille Van; Pinto, Luis Abegão; Stalmans, Ingeborg

    2015-01-01

    Iatrogenic pigment dispersion syndrome generally originates from a repetitive, mechanical trauma to the pigmented posterior epithelium of the iris. This trauma can arise after intraocular surgery, most commonly due to an abnormal contact between the intraocular lens (IOL) and the iris. Whether surgical removal of this primary insult can lead to a successful intraocular pressure (IOP) control remains unclear. Case-series. Patients with IOP elevation and clinical signs of pigment dispersion were screened for a diagnosis of iatrogenic IOL-related pigment dispersion. Three patients in which the IOL or the IOL-bag complex caused a pigment dispersion through a repetitive iris chafing were selected. In two cases, replacement of a sulcus-based single-piece IOL (patient 1) or a sub-luxated in-the-bag IOL (patient 2) by an anterior-chamber (AC) iris-fixed IOL led to a sustained decrease in IOP. In the third case, extensive iris atrophy and poor anatomical AC parameters for IOL implantation precluded further surgical intervention. IOL-exchange appears to be a useful tool in the management of iatrogenic pigment dispersion glaucoma due to inappropriate IOL implantation. This cause-oriented approach seems to be effective in controlling IOP, but should be offered only if safety criteria are met. How to cite this article: Van Mierlo C, Abegao Pinto L, Stalmans I. Surgical Management of Iatrogenic Pigment Dispersion Glaucoma. J Curr Glaucoma Pract 2015;9(1):28-32.

  15. DIY 3D printing of custom orthopaedic implants: a proof of concept study.

    PubMed

    Frame, Mark; Leach, William

    2014-03-01

    3D printing is an emerging technology that is primarily used for aiding the design and prototyping of implants. As this technology has evolved it has now become possible to produce functional and definitive implants manufactured using a 3D printing process. This process, however, previously required a large financial investment in complex machinery and professionals skilled in 3D product design. Our pilot study's aim was to design and create a 3D printed custom orthopaedic implant using only freely available consumer hardware and software.

  16. Meningitis following cochlear implantation: pathomechanisms, clinical symptoms, conservative and surgical treatments.

    PubMed

    Arnold, W; Bredberg, G; Gstöttner, W; Helms, J; Hildmann, H; Kiratzidis, T; Müller, J; Ramsden, R T; Roland, P; Walterspiel, J N

    2002-01-01

    Pneumococcal otogenic meningitis is a rare postsurgical complication that can develop following stapedectomy or after cochlear implantation. The bacterial infection can be fatal in some instances. A recent increase in the incidence of otogenic meningitis among cochlear implant wearers is of concern. The majority of meningitis cases are associated with a 2-component electrode manufactured by one cochlear implant company. The device with the added 'positioner' component has been withdrawn from the market (FDA Public Health Web Notification: Cochlear Implant Recipients may be at Greater Risk for Meningitis, Updated: August 29, 2002, www.fda.gov/cdrh/safety/cochlear.html). Not all cases have been subsequent to otitis media and symptoms have developed from less than 24 h up to a few years after implantation. The purpose of this paper is to review and discuss the pathogenesis, pathology/bacteriology and to elaborate on some clinical features of otogenic meningitis in implanted children and adults. Essential aspects of surgery, electrode design, and cochleostomy seal are discussed. Conclusions are drawn from the available data and recommendations are made for good practice in cochlear implantation and follow-up. Copyright 2002 S. Karger AG, Basel

  17. Angulated Implants for Fabrication of Implant Supported Fixed Partial Denture in the Maxilla

    PubMed Central

    Egbert, Nicholas; Ahuja, Swati; Selecman, Audrey; Wicks, Russell

    2017-01-01

    Until recently, angled abutments have been the only solution to correcting the trajectory of the emergence profile of labially inclined implants in the maxilla. However, the clinical implications of angled abutments reveal several shortcomings. Newly designed angulated implants with a 12-degree restorative platform angulation are an alternative to angled abutments. The purpose of this article was to report a case utilizing new angulated implants (Co-axis, Keystone dental, Burlington, MA, USA) in the premaxilla thereby facilitating fabrication of a multi-unit implant retained fixed dental prosthesis. PMID:29201975

  18. Laminin coatings on implant surfaces promote osseointegration: Fact or fiction?

    PubMed

    Javed, Fawad; Al Amri, Mohammad D; Kellesarian, Sergio Varela; Al-Askar, Mansour; Al-Kheraif, Abdulaziz A; Romanos, Georgios E

    2016-08-01

    To our knowledge from indexed literature, the role of laminins in the expression of osteogenic biomarkers and osseointegration enhancement has not been systematically reviewed. The aim of the present systematic review was to assess the role of laminin coatings on implant surfaces in promoting osseointegration. To address the focused question, "Do laminin coatings on implant surfaces influence osseointegration?", indexed databases were searched from 1965 up to and including November 2015 using various combination of the following keywords: "Bone to implant contact"; "implant"; "laminins"; and "osseointegration". Letters to the Editor, case-reports/case-series, historic reviews, and commentaries were excluded. The pattern of the present systematic review was customized to primarily summarize the pertinent data. Nine studies were included. Six studies were prospective and were performed in animals and 5 studies were in vitro. Results from 8 studies showed that laminin coatings enhanced new bone formation around implants and/or bone-to-implant contact. One study showed that laminin coated implants surfaces did not improve osseointegration. On experimental grounds, laminin coatings seem to enhance osteogenic biomarkers expression and/or osseointegration; however, from a clinical perspective, further randomized control trials are needed to assess the role of laminin coatings in promoting osseointegration around dental implants. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  19. Evisceration surgery in a highly specialized center in Mexico: A retrospective study of 7 years of experience.

    PubMed

    Arellano-Ganem, M G; Zuazo, F; González, M; Abdala, A; Olvera-Morales, O; Tovilla-Canales, J L; Nava-Castañeda, Á

    2017-02-01

    Evisceration is currently becoming the technique of choice in the treatment of certain eye diseases, including, among others, painful blind eye and endophthalmitis. The most widely used implants are currently the hydroxyapatite and porous polyethylene for the rehabilitation of the anophthalmic socket. To describe the indications, type of implant material used, and complications in evisceration surgery. A retrospective, observational, descriptive study based on clinical records of patients that underwent evisceration between 2008 and 2015 in the Instituto Fundación Conde de Valenciana, Mexico. A total of 186 evisceration surgeries were performed, of which 52.7% of the patients were men. The mean age was 54 years. The right eye was eviscerated in 53% of cases, and 79.2% had a vision of no light perception. Most patients had preoperative pain. The most common diagnosis for which evisceration was performed was endophthalmitis. Phthisis bulbi was reported in 20 eyes. A primary implant was inserted in 86.81% of the cases, with 34.81% of the implants being made of porous polyethylene. Four cases showed extrusion of the implant, with 2 cases of porous polyethylene. The ocular prosthesis was tolerated in 91% of cases. There were no cases of sympathetic ophthalmia. Evisceration is shown to be a good alternative to enucleation in cases where the sclera can be preserved, showing a low incidence of sympathetic ophthalmia. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis.

    PubMed

    Hamada, Yusuke; Prabhu, Srividya; John, Vanchit

    2016-01-01

    As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as "erratic healing," may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications.

  1. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis

    PubMed Central

    Prabhu, Srividya

    2016-01-01

    As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as “erratic healing,” may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications. PMID:27807485

  2. Simulated bone remodeling around two types of osseointegrated implants for direct fixation of upper-leg prostheses.

    PubMed

    Tomaszewski, P K; Verdonschot, N; Bulstra, S K; Rietman, J S; Verkerke, G J

    2012-11-01

    Direct attachment of an upper leg prosthesis to the skeletal system by a percutaneous implant is an alternative solution to the traditional socket fixation. In this study, we investigated long-term periprosthetic bone changes around two types of fixation implants using two different initial conditions, namely immediate post-amputation implantation and the conventional implantation after considerable time of socket prosthesis use. We questioned the difference in bone modeling response the implants provoked and if it could lead to premature bone fracture. Generic CT-based finite element models of an intact femoral bone and amputated bone implanted with models of two existing direct-fixation implants, the OPRA system (Integrum AB) and the ISP Endo/Exo prosthesis (ESKA Implants AG) were created for this study. Adaptive bone-remodeling simulations used the heel-strike and toe-off loads from a normal walking cycle. The bone loss caused by prolonged use of socket prosthesis had more severe effects on the ultimate bone quality than adaptation induced by the direct-fixation implants. Both implants showed considerable bone remodeling; the titanium screw implant (OPRA system) provoked more bone loss than the porous coated CoCrMo stem (ISP implant). The chance of the peri-prosthetic bone fracture remained higher for the post-socket case as compared to the direct amputation cases. In conclusion, both direct-fixation implants lead to considerable bone loss and bone loss is more severe after a prolonged period of post-socket use. Hence, from a biomechanical perspective it is better to limit the post-socket time and to re-design direct fixation devices to reduce bone loss and the probability of peri-prosthetic bone fractures. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Microleakage at the Different Implant Abutment Interface: A Systematic Review

    PubMed Central

    Chowdhary, Ramesh; Kumari, Shail

    2017-01-01

    Introduction Presence of gap at the implant-abutment interface, leads to microleakage and accumulation of bacteria which can affect the success of dental implants. Aim To evaluate the sealing capability of different implant connections against microleakage. Materials and Methods In January 2017 an electronic search of literature was performed, in Medline, EBSCO host and Pubmed data base. The search was focused on ability of different implant connections in preventing microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full text reading. Results In this systematic review, literature search initially resulted in 78 articles among which 30 articles only fulfilled the criteria for inclusion and were finally included in the review. Almost all the studies showed that there was some amount of microleakage at abutment implant interface. Microleakage was very less in Morse taper implants in comparison to other implant connections. Majority of studies showed less microleakage in static loading conditions and microleakage increases in dynamic loading conditions. Conclusion In this systematic review maximum studies showed that there was some amount of microleakage at abutment implant interface. External hexagon implants failed completely to prevent microleakage in both static and dynamic loading conditions of implants. Internal hexagon implants mainly internal conical (Morse taper) implants are very promising in case of static loading and also showed less microleakage in dynamic loading conditions. Torque recommended by manufacturer should be followed strictly to get a better seal at abutment implant interface. Zirconia abutments are more to microleakage than Titanium abutments and there use should be discouraged. Zirconia abutments should be only restricted to cases where there was very high demand of aesthetics. PMID:28764310

  4. Magnet-Retained Two-Mini-Implant Overdenture: Clinical and Mechanical Consideration.

    PubMed

    Ishida, Yuichi; Kumar, H S Kiran; Goto, Takaharu; Watanabe, Megumi; Wigianto, Rudi; Ichikawa, Tetsuo

    2016-10-10

    Two-implant overdentures have become the accepted treatment for restoring mandibular edentulism. The dimensions of regular implants sometimes limit their use, such as in the case of narrow ridges. Mini-implants with reduced diameters (less than 3.0 mm) enable insertion into narrow ridges. A magnet-retained two-mini-implant overdenture system was developed and is described in this paper. Additionally, we describe a clinical mandibular procedure using the system and evaluate its biomechanical performance.

  5. Magnet-Retained Two-Mini-Implant Overdenture: Clinical and Mechanical Consideration

    PubMed Central

    Ishida, Yuichi; Kumar, H. S. Kiran; Goto, Takaharu; Watanabe, Megumi; Wigianto, Rudi; Ichikawa, Tetsuo

    2016-01-01

    Two-implant overdentures have become the accepted treatment for restoring mandibular edentulism. The dimensions of regular implants sometimes limit their use, such as in the case of narrow ridges. Mini-implants with reduced diameters (less than 3.0 mm) enable insertion into narrow ridges. A magnet-retained two-mini-implant overdenture system was developed and is described in this paper. Additionally, we describe a clinical mandibular procedure using the system and evaluate its biomechanical performance. PMID:29563477

  6. Anterior minimally invasive approach for total hip replacement: five-year survivorship and learning curve.

    PubMed

    Müller, Daniel A; Zingg, Patrick O; Dora, Claudio

    2014-01-01

    Opponents associate minimally invasive total hip replacement (THR) with additional risks, potentially resulting in increased implant failure rates. The purpose was to document complications, quality of implant positioning and five-year survivorship of THR using the AMIS approach and to test the hypothesis that eventual high complication and revision rates would be limited to an early series and be avoided by junior surgeons who get trained by a senior surgeon. A consecutive series of 150 primary THR implanted during the introduction of the AMIS technique in the department was retrospectively analysed for complications, implant positioning and implant survival after a minimum of five years. Survivorship curves of implants were compared between different surgeons and time periods. Due to implant revision for any reason the five-year survival rate was 94.6%, 78.9% for the first 20 and 96.8% for the following 130 AMIS procedures (p = 0.001). The hazard ratio for implant failure was 0.979 indicating a risk reduction of 2% every further case. The five-year implant survivorship of those procedures performed by two junior surgeons was 97.7%. We conclude that adoption of AMIS temporarily exposed patients to a higher risk of implant revisions, which normalised after the first 20 cases and that experience from a single surgeon's learning curve could effectively be taught to junior surgeons.

  7. Cochlear implants in Waardenburg syndrome.

    PubMed

    Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig

    2006-07-01

    Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.

  8. Histologic analysis of resorbable blasting media surface implants retrieved from humans: a report of two cases

    PubMed Central

    2016-01-01

    The purpose of this study is to evaluate the degree of osseointegration of resorbable blasting media (RBM) surface implants retrieved from humans. Three implants in the mandibular molar region that were surface-treated with RBM were retrieved from two patients. The implants were used to manufacture specimens in order to measure the bone-implant contact (BIC) ratio. The BIC ratios of the three implants were found to be an average of 69.0%±9.1%. In conclusion, that RBM surface implants are integrated into the host environment with histological significance and the BIC ratio of the RBM surface-treated implant was not significantly different from that of other surface-treated implants. PMID:26904493

  9. Guided bone regeneration using nonexpanded polytetrafluoroethylene membranes in preparation for dental implant placements--a report of 420 cases.

    PubMed

    Barboza, Eliane Porto; Stutz, Bianca; Ferreira, Vinícius Farias; Carvalho, Waldimir

    2010-02-01

    The biologic principle of guided bone regeneration has been successfully used to prevent bone loss in extraction sites. This study comprises 420 cases of alveolar ridge maintenance in preparation for dental implant placements. Nonexpanded polytetrafluoroethylene membranes were positioned over all extraction sites and left intentionally exposed. Lyophilized mineralized bone allografts were used to prevent membrane collapse when buccal bone walls were lost. Membranes were removed at week 4. At the time of implant placements, all sites presented soft tissue compatibility with keratinized gingiva. The mucogingival junction position seemed to be preserved. Exposed nonexpanded polytetrafluoroethylene membranes associated, or not, with bone graft provide tissue formation suitable for implant placement.

  10. Delayed-onset streptococcus pyogenes endophthalmitis following Ahmed glaucoma valve implantation.

    PubMed

    Bayraktar, Zerrin; Kapran, Ziya; Bayraktar, Sükrü; Acar, Nur; Unver, Yaprak Banu; Gök, Kemran

    2005-01-01

    To report a case of delayed-onset Streptococcus pyogenes endophthalmitis following implantation of an Ahmed glaucoma valve. A 10-year-old patient presented with acute endophthalmitis 1 year after Ahmed glaucoma valve implantation. The conjunctiva and Tenon's capsule over the valve plate had been penetrated by one of the polypropylene fixation sutures. The valve was removed, and pars plana vitrectomy was performed. Vitreous specimens and removal of the discharge over the plate revealed Streptococcus pyogenes. This is the first documented case of Streptococcus pyogenes endophthalmitis following Ahmed glaucoma valve implantation. We think the conjunctival buttonhole caused by the polypropylene suture provided an entry site for the infection. (c) Japanese Ophthalmological Society 2005.

  11. The formation of an organic coat and the release of corrosion microparticles from metallic magnesium implants.

    PubMed

    Badar, Muhammad; Lünsdorf, Heinrich; Evertz, Florian; Rahim, Muhammad Imran; Glasmacher, Birgit; Hauser, Hansjörg; Mueller, Peter P

    2013-07-01

    Magnesium alloys have been proposed as prospective degradable implant materials. To elucidate the complex interactions between the corroding implants and the tissue, magnesium implants were analyzed in a mouse model and the response was compared to that induced by Ti and by the resorbable polymer polyglactin, respectively. One month after implantation, distinct traces of corrosion were apparent but the magnesium implants were still intact, whereas resorbable polymeric wound suture implants were already fragmented. Analysis of magnesium implants 2weeks after implantation by energy-dispersive X-ray spectroscopy indicated that magnesium, oxygen, calcium and phosphate were present at the implant surface. One month after implantation, the element composition of the outermost layer of the implant was indicative of tissue without detectable levels of magnesium, indicating a protective barrier function of this organic layer. In agreement with this notion, gene expression patterns in the surrounding tissue were highly similar for all implant materials investigated. However, high-resolution imaging using energy-filtered transmission electron microscopy revealed magnesium-containing microparticles in the tissue in the proximity of the implant. The release of such corrosion particles may contribute to the accumulation of calcium phosphate in the nearby tissue and to bone conductive activities of magnesium implants. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  12. What a difference two days make: "personalized" embryo transfer (pET) paradigm: a case report and pilot study.

    PubMed

    Ruiz-Alonso, M; Galindo, N; Pellicer, A; Simón, C

    2014-06-01

    Embryo implantation requires that the blastocyst will attach during the receptive stage of the endometrium, known as window of implantation (WOI). Historically, it has been assumed that the WOI is always constant in all women. However, molecular analyses of endometrial receptivity demonstrates a personalized WOI (pWOI) that is displaced in one out of four patients suffering from recurrent implantation failure (RIF) of endometrial origin and illustrates the utility of a personalized endometrial diagnostic approach. Here, we report a clinical case of successful personalized embryo transfer (pET) after four IVF and three oocyte donation failed attempts in which different embryo transfer strategies were attempted. This case report is complemented by a pilot study of 17 patients undergoing oocyte donation and who suffered failed implantations with routine embryo transfer (ET) but were then treated with pET after the personalized diagnosis of their WOI.

  13. Suspected bacterial endophthalmitis following sustained-release dexamethasone intravitreal implant: a case report.

    PubMed

    Arıkan Yorgun, Mücella; Mutlu, Melek; Toklu, Yasin; Cakmak, Hasan Basri; Cağıl, Nurullah

    2014-06-01

    A 58-year-old man admitted to our opthalmology department with the complaint of branch retinal vein occlusion. He was treated with intravitreal Ozurdex in the right eye. Two days after the injection, the patient presented with ocular pain and the visual acuity was hand movement. A diagnosis of endophthalmitis was made. We performed emergent pars plana vitrectomy (PPV) and the implant was removed from the vitreous cavity using a retinal forceps. A combination of vancomycin 1.0 mg and amikacin 0.4 mg was injected intravitreally. However, because of the blurring in the vitreus one week after the procedure, phacoemulsification and a repeat PPV was performed. Five days after the last procedure the signs and symptoms of endophthalmitis were resolved. Our case demonstrated that endophthalmitis could develop after intravitreal implantation of Ozurdex. Surgical removal of the implant and immediate vitrectomy seems to be a useful treatment option in these cases.

  14. Neuropathic pain resulting from implant placement: case report and diagnostic conclusions.

    PubMed

    Leckel, M; Kress, B; Schmitter, M

    2009-07-01

    Temporary or persisting dysesthesia of the nervus alveolaris inferior has often been described as a complication of implant surgery of the lower mandible. In most cases, lesion of the nerve results in anaesthesia of the innervated region, a symptom clearly indicative of correct diagnosis. In our case report, however, a minor perforation of the roof of the mandibular canal during implant placement apparently provoked discrete irritation of the nerve, resulting in persistent neuropathic pain without concomitant hypesthesia or dysesthesia. Because the canal could not be detected in conventional dental radiographs, this uncharacteristic situation made correct diagnosis difficult and led to unnecessary surgical procedures including extraction of adjacent teeth. Medical imaging [computed tomography (CT)] finally revealed the close proximity of the apex of the implant and the bony structure of the mandibular canal. The effect on the nervus alveolaris inferior was also demonstrated using an innovative high-resolution dental magnetic-resonance-imaging technique reflecting vascular reactions of the neurovascular bundle after potentially damaging surgical intervention. After removal of the causative implant, the pain gradually faded over a period of a year.

  15. [Clinical effect on migraine treated with acupoint implantation].

    PubMed

    Feng, Yanting

    2016-04-01

    To observe the clinical efficacy on migraine treated with acupoint implantation. Sixty cases of migraine were randomized into a implantation group and an electroacupuncture (EA) group, 30 cases in each one. In the implantation group, implantation was used at Fengchi (GB 20), Taiyang (EX-HN 5), Waiguan (TE 5), Yanglingquan (GB 34), etc., once every 2 weeks, for 4 weeks totally. In the EA group, the acupoints were the same as the implantation group, and EA was applied to Fengchi (GB 20) and Taiyang (EX-HN 5), Yanglingquan (GB 34) and Zusanli (ST 36), once every two days, for 4 weeks totally. The visual analogue scale (VAS) was adopted before and after treatment and the clinical efficacy was compared between the two groups. After treatment, VAS score was reduced in the implantation group and the EA group as compared with that before treatment (both P < 0.01). After treatment, VAS score in the implantation group was lower than that in the EA group (P < 0.01). The difference in VAS score before and after treatment in the implantation group was improved apparently as compared with that in the EA group (P < 0.01). The total effective rate in the implantation group was higher than that in the EA group (P < 0.05). The acupoint implantation reduces VAS score in the patients of migraine and its clinical efficacy is better than that in the EA group. The therapy presents the long-term clinical effect and deserves to be promoted in clinical practice.

  16. Comparative study between unilateral and bilateral cochlear implantation in children of 1 and 2 years of age.

    PubMed

    Escorihuela García, Vicente; Pitarch Ribas, María Ignacia; Llópez Carratalá, Ignacio; Latorre Monteagudo, Emilia; Morant Ventura, Antonio; Marco Algarra, Jaime

    2016-01-01

    The studies that have evaluated the effectiveness of bilateral cochlear implantation in children suggest an improvement in hearing about sound localization and speech discrimination. In this paper we show the differences in audio-linguistic achievements with early bilateral cochlear implantation versus unilateral, and differences between simultaneous and sequential bilateral implantation. We present 88 children with bilateral profound sensorineural hearing loss, treated with bilateral cochlear implantation in 32 cases and unilateral in 56 cases, during the first 12 months (27 children) of life and between 12 and 24 months (61 children). We conducted a statistical comparison of both groups in the audiometry, IT-Mais, Nottingham, LittlEars scales and verbal tests. No significant differences in hearing thresholds and questionnaires between unilateral and bilateral implantation were detected in either the first or second year. Verbal tests do show statistically significant differences: children with bilateral cochlear implant obtain 100% recognition of disyllabic and phrases within 2-3 years after implantation whilst children with one implant do not obtain those results at 5 years after surgery. No differences between simultaneous and sequential bilateral implantation were detected. We emphasize the importance of ensuring good early audiological screening, to carry out an early and bilateral cochlear implantation with the consequent development of audio-language skills similar to normal hearing children. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  17. Managing peri-implant bone loss: current understanding.

    PubMed

    Aljateeli, Manar; Fu, Jia-Hui; Wang, Hom-Lay

    2012-05-01

    With the improved macro- and micro-designs, dental implants enjoy a high survival rate. However, peri-implant bone loss has recently emerged to be the focus of implant therapy. As such, researchers and clinicians are in need of finding predictable techniques to treat peri-implant bone loss and stop its progression. Literature search on the currently available treatment modalities was performed and a brief description of each modality was provided. Numerous techniques have been proposed and none has been shown to be superior and effective in managing peri-implant bone loss. This may be because of the complex of etiological factors acting on the implant-supported prosthesis hence the treatment approach has to be individually tailored. Due to the lack of high-level clinical evidence on the management of peri-implant bone loss, the authors, through a literature review, attempt to suggest a decision tree or guideline, based on sound periodontal surgical principles, to aid clinicians in managing peri-implantitis associated bone loss. © 2011 Wiley Periodicals, Inc.

  18. Anesthetic Management of Cardioband Implantation: Data From a Preliminary Experience and New Insights.

    PubMed

    Pieri, Marina; Belletti, Alessandro; Oriani, Alessandro; Landoni, Giovanni; Latib, Azeem; Mangieri, Antonio; Colombo, Antonio; Zangrillo, Alberto; Monaco, Fabrizio

    2017-04-01

    Percutaneous procedures for the treatment of mitral valve disease represent valuable therapeutic options for high-risk patients. The anesthetic management of these patients is complex, as they often suffer from cardiac failure and present multiple comorbidities. A recently developed device for transcatheter mitral valve annuloplasty (Cardioband - Valtech Cardio, Or Yehuda, Israel) is now available in clinical practice. The aim of this study was to present the authors' experience with Cardioband device implantation and to describe their anesthetic strategy. Retrospective study. Cardiac catheterization laboratory of a teaching hospital. Thirteen patients undergoing Cardioband implantation. All the procedures were performed under general anesthesia with continuous transesophageal echocardiographic monitoring. Three-dimensional echocardiography, inotropic therapy, cardiac pacing, and mechanical circulatory support always were available and performed as needed. Mean age was 73±7.1 years, and mean preoperative ejection fraction was 38±7.4%. No complications related to anesthetic management were recorded. The authors observed 1 episode of device malfunction and 1 case of accidental damage to the circumflex artery. Postoperative complications were observed in 3 patients, involving detachment of the anchors, anemia requiring transfusions, vascular injury, and new-onset atrial fibrillation. Six patients (46%) required ICU admission. All patients (100%) were discharged from the hospital. Cardioband device implantation under general anesthesia is a feasible approach when performed by skilled physicians with all the expertise and the resources of high-volume centers used to dealing with severely ill patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Cortical Auditory Evoked Potentials with Simple (Tone Burst) and Complex (Speech) Stimuli in Children with Cochlear Implant

    PubMed Central

    Martins, Kelly Vasconcelos Chaves; Gil, Daniela

    2017-01-01

    Introduction  The registry of the component P1 of the cortical auditory evoked potential has been widely used to analyze the behavior of auditory pathways in response to cochlear implant stimulation. Objective  To determine the influence of aural rehabilitation in the parameters of latency and amplitude of the P1 cortical auditory evoked potential component elicited by simple auditory stimuli (tone burst) and complex stimuli (speech) in children with cochlear implants. Method  The study included six individuals of both genders aged 5 to 10 years old who have been cochlear implant users for at least 12 months, and who attended auditory rehabilitation with an aural rehabilitation therapy approach. Participants were submitted to research of the cortical auditory evoked potential at the beginning of the study and after 3 months of aural rehabilitation. To elicit the responses, simple stimuli (tone burst) and complex stimuli (speech) were used and presented in free field at 70 dB HL. The results were statistically analyzed, and both evaluations were compared. Results  There was no significant difference between the type of eliciting stimulus of the cortical auditory evoked potential for the latency and the amplitude of P1. There was a statistically significant difference in the P1 latency between the evaluations for both stimuli, with reduction of the latency in the second evaluation after 3 months of auditory rehabilitation. There was no statistically significant difference regarding the amplitude of P1 under the two types of stimuli or in the two evaluations. Conclusion  A decrease in latency of the P1 component elicited by both simple and complex stimuli was observed within a three-month interval in children with cochlear implant undergoing aural rehabilitation. PMID:29018498

  20. BCA-kMC Hybrid Simulation for Hydrogen and Helium Implantation in Material under Plasma Irradiation

    NASA Astrophysics Data System (ADS)

    Kato, Shuichi; Ito, Atsushi; Sasao, Mamiko; Nakamura, Hiroaki; Wada, Motoi

    2015-09-01

    Ion implantation by plasma irradiation into materials achieves the very high concentration of impurity. The high concentration of impurity causes the deformation and the destruction of the material. This is the peculiar phenomena in the plasma-material interaction (PMI). The injection process of plasma particles are generally simulated by using the binary collision approximation (BCA) and the molecular dynamics (MD), while the diffusion of implanted atoms have been traditionally solved by the diffusion equation, in which the implanted atoms is replaced by the continuous concentration field. However, the diffusion equation has insufficient accuracy in the case of low concentration, and in the case of local high concentration such as the hydrogen blistering and the helium bubble. The above problem is overcome by kinetic Monte Carlo (kMC) which represents the diffusion of the implanted atoms as jumps on interstitial sites in a material. In this paper, we propose the new approach ``BCA-kMC hybrid simulation'' for the hydrogen and helium implantation under the plasma irradiation.

  1. Thoracic Radiculopathy following Spinal Cord Stimulator Implantation Treated with Corticosteroids.

    PubMed

    Ghosh, Ritam; Holland, Ryan; Mammis, Antonios

    2017-04-01

    Spinal cord stimulation has been used since 1967 to manage chronic neuropathic pain. Although effective, the literature describes the complication rate to be as high as 35%. One rare complication following spinal cord stimulator (SCS) implantation is the development of radicular pain. We present a case series of 2 patients implanted with SCSs who developed thoracic radiculopathy following implantation that resolved with corticosteroids. Although this complication was previously thought to require surgical intervention, this case series describes the use of corticosteroids to resolve postimplantation thoracic radiculopathy. Two patients were studied in this case series who received permanent thoracic implantation of a paddle lead SCS. Several days later, both developed back pain radiating toward the umbilicus in a dermatomal pattern consistent with thoracic radiculopathy. Corticosteroids were administered to relieve this pain. One received 6 mg dexamethasone intravenously every 6 hours followed by an oral dexamethasone taper for 1 week. The other was treated with an oral methylprednisolone taper for 2 weeks. Upon follow-up, both patients no longer complained of the thoracic radiculopathy and were satisfied with the pain relief the stimulators provided. In conclusion, postsurgical radicular pain is a rare but troubling complication of SCS implantation. In order to avoid further surgical complications or the need to explant a device that provides satisfactory paresthesia coverage, pharmacologic management is desirable. This case series has demonstrated that the use of corticosteroids can effectively resolve postimplantation thoracic radicular pain in a specific subgroup of patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Simultaneous Implantation of an Ahmed and Baerveldt Glaucoma Drainage Device for Uncontrolled Intraocular Pressure in Advanced Glaucoma.

    PubMed

    Rao, Veena S; Christenbury, Joseph; Lee, Paul; Allingham, Rand; Herndon, Leon; Challa, Pratap

    2017-02-01

    To evaluate efficacy and safety of a novel technique, simultaneous implantation of Ahmed and Baerveldt shunts, for improved control of intraocular pressure (IOP) in advanced glaucoma with visual field defects threatening central fixation. Retrospective case series; all patients receiving simultaneous Ahmed and Baerveldt implantation at a single institution between October 2004 and October 2009 were included. Records were reviewed preoperatively and at postoperative day 1, week 1, month 1, month 3, month 6, year 1, and yearly until year 5. Outcome measures included IOP, best-corrected visual acuity, visual field mean deviation, cup to disc ratio, number of glaucoma medications, and complications. Fifty-nine eyes were identified; mean (±SD) follow-up was 26±23 months. Primary open-angle glaucoma was most common (n=37, 63%). Forty-six eyes (78%) had prior incisional surgery. Mean preoperative IOP was 25.5±9.8 mm Hg. IOP was reduced 50% day 1 (P<0.001, mean 12.7±7.0 mm Hg), which persisted throughout follow-up. At year 1, cup to disc ratio and mean deviation were stable with decreased best-corrected visual acuity from logMAR 0.72±0.72(20/100) to 1.06±1.13(20/200) (P=0.007). The Kaplan-Meier survival analysis showed median and mean survival of 1205 and 829±91 days, respectively. Complication rate was 47%. IOP is markedly reduced postoperative day 1 following double glaucoma tube implantation with effects persisting over postoperative year 1 and up to year 5. Complications were higher than that seen in reports of single shunt implantation, which may be explained by patient complexity in this cohort. This technique may prove a promising novel approach for management of uncontrolled IOP in advanced glaucoma.

  3. Use of (N-1)-D expansions for N-D phase unwrapping in MRI

    NASA Astrophysics Data System (ADS)

    Bones, Philip J.; King, Laura J.; Millane, Rick P.

    2017-09-01

    In MRI the presence of metal implants causes severe artifacts in images and interferes with the usual techniques used to separate fat signals from other tissues. In the Dixon method, three images are acquired at different echo times to enable the variation in the magnetic field to be estimated. However, the estimate is represented as the phase of a complex quantity and therefore suffers from wrapping. High field gradients near the metal mean that the phase estimate is undersampled and therefore challenging to unwrap. We have developed POP, phase estimation by onion peeling, an algorithm which unwraps the phase along 1-D paths for a 2-D image obtained with the Dixon method. The unwrapping is initially performed along a closed path enclosing the implant and well separated from it. The recovered phase is expanded using a smooth periodic basis along the path. Then, path-by-path, the estimate is applied to the next path and then the expansion coefficients are estimated to best fit the wrapped measurements. We have successfully tested POP on MRI images of specially constructed phantoms and on a group of patients with hip implants. In principle, POP can be extended to 3-D imaging. In that case, POP would entail representing phase with a suitably smooth basis over a series of surfaces enclosing the implant (the "onion skins"), again beginning the phase estimation well away from the implant. An approach for this is proposed. Results are presented for fat and water separation for 2-D images of phantoms and actual patients. The practicality of the method and its employment in clinical MRI are discussed.

  4. Reliability of computer designed surgical guides in six implant rehabilitations with two years follow-up.

    PubMed

    Giordano, Mauro; Ausiello, Pietro; Martorelli, Massimo; Sorrentino, Roberto

    2012-09-01

    To evaluate the reliability and accuracy of computer-designed surgical guides in osseointegrated oral implant rehabilitation. Six implant rehabilitations, with a total of 17 implants, were completed with computer-designed surgical guides, performed with the master model developed by muco-compressive and muco-static impressions. In the first case, the surgical guide had exclusively mucosal support, in the second case exclusively dental support. For all six cases computer-aided surgical planning was performed by virtual analyses with 3D models obtained by dental scan DICOM data. The accuracy and stability of implant osseointegration over two years post surgery was then evaluated with clinical and radiographic examinations. Radiographic examination, performed with digital acquisitions (RVG - Radio Video graph) and parallel techniques, allowed two-dimensional feedback with a margin of linear error of 10%. Implant osseointegration was recorded for all the examined rehabilitations. During the clinical and radiographic post-surgical assessments, over the following two years, the peri-implant bone level was found to be stable and without appearance of any complications. The margin of error recorded between pre-operative positions assigned by virtual analysis and the post-surgical digital radiographic observations was as low as 0.2mm. Computer-guided implant surgery can be very effective in oral rehabilitations, providing an opportunity for the surgeon: (a) to avoid the necessity of muco-periosteal detachments and then (b) to perform minimally invasive interventions, whenever appropriate, with a flapless approach. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  5. Clinical application of stereolithographic surgical guide with a handpiece guidance apparatus: a case report.

    PubMed

    Ozan, Oguz; Seker, Emre; Kurtulmus-Yilmaz, Sevcan; Ersoy, Ahmet Ersan

    2012-10-01

    The success of implant-supported restorations depends on the treatment planning and the transfer of planning through the surgical field. Recently, new computer-aided design and manufacturing (CAD/CAM) techniques, such as stereolithographic (SLA) rapid prototyping, have been developed to fabricate surgical guides to improve the precision of implant placement. The objective of the present case is to introduce a recently developed SLA surgical guide system into the rehabilitation of a 62-year-old male patient with mandibular edentulism. After obtaining a cone-beam computerized tomography (CBCT) scan of the mandible with a radiographic template, the images were transferred into a 3-dimensional (3D) image-based software for implant planning. The StentCad Beyond SLA surgical guide system, which is a combination of a currently used surgical template with pilot hollows and a surgical handpiece guidance apparatus, was designed to transfer a preoperatively defined implant position onto the surgical site without any drill-surgical guide contact. For the fabrication of this system, a surgical handpiece was scanned by a laser optical scanner and a mucosa-supported surgical guide was designed according to the patient's 3D model, which was attained from the CBCT images. Four dental implants were inserted through the SLA surgical guide system by a torque-controlled surgical handpiece to the interforaminal region via a flapless surgical procedure. Implants were assessed 3 months after surgery, and an implant-retained mandibular overdenture was fabricated. The present case emphasizes that CAD/CAM SLA surgical guides, along with CBCT images and scanning data, may help clinicians plan and place dental implants.

  6. Incidence of Prosthetic Complications associated with Implant-borne Prosthesis in a Sleep Disorder Center.

    PubMed

    Suneel, Venkatesh B; Kotian, Santhosh; Jujare, Ravikanth H; Shetty, Adarsh K; Nidhi, Sneh; Grover, Shehkar

    2017-09-01

    Obstructive sleep apnea (OSA) is one of the common prevalent conditions present worldwide. The process of abnormal habits related to clenching and grinding of teeth is referred to as bruxism and is characterized under the heading of parafunctional activity of the masticatory system. Osseointegrated dental implants represent advancements in the field of odontology. Despite its high success rate, failure and complications are often associated with dental implant treatment due to a number of factors. Hence, we aimed for the present study to assess the incidence of prosthetic complications in patients rehabilitated with implant-borne prosthesis in a sleep disorder unit. The present study included the assessment of all the patients who underwent prosthetic rehabilitation by dental implants. An experienced registered prosthodontist was given duty for examination of all the cases from the record file data. Prosthetic complications in the patients were identified using photographs, radiographs, and all other relevant data of the patients obtained from the record files. All types of complications and other factors were recorded separately and analyzed. While correlating the prosthetic complications in OSA patients grouped based on number of dental implants, nonsignificant results were obtained. Significant correlation was observed while comparing the prosthetic complications divided based on type of prosthesis. Fracture of the porcelain was observed in four and eight cases respectively, of screwed and cemented dental implant cases. Some amount of significant correlation existed between the incidences of prosthetic complications and OSA. Proper history of the patients undergoing dental implant procedures should be taken to avoid failure.

  7. Management of pseudophakic myopic anisometropic amblyopia with piggyback Visian® implantable collamer lens.

    PubMed

    Eissa, Sherif A

    2017-03-01

    To assess the outcomes of sulcus implantation of the Visian ® implantable collamer lens (ICL) to correct pseudophakic myopic anisometropic amblyopia with myopic shift and/or primary refractive overcorrection. Prospective case series enrolled 14 pseudophakic eyes of 14 patients, 5-9 years old, with history of cataract surgery and primary in the bag-intraocular lenses (IOL) implantation, followed by myopic shift and/or refractive overcorrection and anisometropic amblyopia of variable degrees. All cases had implantation of a piggyback ICL/toric ICL, to correct the myopia/myopic astigmatism. Preoperatively, we evaluated the uncorrected distance visual acuity (UCVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent (MRSE), intraocular pressure (IOP) and endothelial cell density (ECD). We assessed the position and vaulting of the ICLs on slit lamp examination and confirmed by Scheimpflug tomography. Postoperative follow-up was at 1st week and 1, 3, 6, 9, 12, 18 and 24 months. Uncorrected distance visual acuity improved in all cases, and CDVA improved in 11 amblyopic eyes (2-4 lines). There was no evidence of interlenticular opacification (ILO) throughout the 2-year follow-up. Two cases were complicated with early postoperative acute elevation of IOP and were controlled with topical beta-blockers. Postoperative acute anterior uveitis occurred in six eyes and controlled by topical steroids. Implantable collamer lens (ICL) vault was measured using Pentacam, with mean value of 470 ± 238 μm. Sulcus implantation of the secondary piggyback ICL to correct unilateral pseudophakic myopic refractive error in children was safe, efficient, predictable and well tolerated in management of anisometropic amblyopia in all eyes. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  8. Monoclonal origin of peritoneal implants and lymph node deposits in serous borderline ovarian tumors (s-BOT) with high intratumoral homogeneity.

    PubMed

    Horn, Lars-Christian; Höhn, Anne K; Einenkel, Jens; Siebolts, Udo

    2014-11-01

    Molecular studies have shown that the most prevalent mutations in serous ovarian borderline tumors (s-BOT) are BRAF and/or KRAS alterations. About one third of s-BOT represent peritoneal implants and/or lymph node involvement. These extraovarian deposits may be monoclonal or polyclonal in origin. To test both the hypotheses, mutational analyses using pyrosequencing for BRAF codon 600 and KRAS codon 12/13 and 61 of microdissected tissue was performed in 15 s-BOT and their invasive and noninvasive peritoneal implants. Two to 6 implants from different peritoneal sites were examined in 13 cases. Lymph node deposits were available for the analysis in 3 cases. Six s-BOT showed mutation in exon 2 codon 12 of the KRAS proto-oncogen. Five additional cases showed BRAF p.V600E mutation representing an overall mutation rate of 73.3%. Multiple (2-6) peritoneal implants were analyzed after microdissection in 13 of 15 cases. All showed identical mutational results when compared with the ovarian site of the disease. All lymph node deposits, including those with multiple deposits in different nodes, showed identical results, suggesting high intratumoral mutational homogeneity. The evidence presented in this study and the majority of data reported in the literature support the hypothesis that s-BOT with their peritoneal implants and lymph node deposits show identical mutational status of BRAF and KRAS suggesting a monoclonal rather than a polyclonal disease regarding these both tested genetic loci. In addition, a high intratumoral genetic homogeneity can be suggested. In conclusion, the results of the present study support the monoclonal origin of s-BOT and their peritoneal implants and lymph node deposits.

  9. Electroconvulsive therapy in patients with skull defects or metallic implants: a review of the literature and case report.

    PubMed

    Amanullah, Shabbir; Delva, Nicholas; McRae, Harold; Campbell, Laura A; Cole, Julie

    2012-01-01

    Head injury is often associated with psychiatric morbidity. While it is well understood that the loss of critical areas of the brain may play a role in cognitive dysfunction and change in personality, head injury can also have profound effects on mood and cognition. The role of medications in the treatment of mood disorders associated with brain injury is well documented, and there is also evidence favoring the use of electroconvulsive therapy (ECT) in this context. However, data are limited on the use of ECT in patients with skull defects or metallic head implants. First, a review of the literature on use of ECT in patients with metallic head implants is provided. Electronic databases and online sites, including PubMed, Cochrane Library of Systematic Reviews, and UpToDate, were used to search for relevant articles and case reports on the use of ECT in patients with and without metallic implants in the head (1964 to 2009). The search terms electroconvulsive, electroconvulsive therapy, ECT, electroshock therapy, EST, head injury, brain injury, metallic plates, metallic implants, skull prosthesis, and depression were used interchangeably. The search produced 7 articles discussing exclusively the use of ECT in patients with a metallic skull plate. Second, the case of the successful and safe use of ECT in an individual with a previous history of brain trauma and metallic plate implantation is described. Most cases of head injury are managed by neurologists and rehabilitation consultants; the more severe cases of depression and other mood disorders tend to be referred for specialist psychiatric care. With greater degrees of deficit following head injury, management becomes more complicated. Our patient showed positive results with ECT, including improvement in depressive features and resolution of suicidal ideas/plans. ECT is an effective and safe alternative in patients with a history of brain trauma and metallic plate implantation who subsequently develop treatment-resistant depression and associated suicidal ideas or plans refractory to management with medications.

  10. Device-based local delivery of siRNA against mammalian target of rapamycin (mTOR) in a murine subcutaneous implant model to inhibit fibrous encapsulation.

    PubMed

    Takahashi, Hironobu; Wang, Yuwei; Grainger, David W

    2010-11-01

    Fibrous encapsulation of surgically implanted devices is associated with elevated proliferation and activation of fibroblasts in tissues surrounding these implants, frequently causing foreign body complications. Here we test the hypothesis that inhibition of the expression of mammalian target of rapamycin (mTOR) in fibroblasts can mitigate the soft tissue implant foreign body response by suppressing fibrotic responses around implants. In this study, mTOR was knocked down using small interfering RNA (siRNA) conjugated with branched polyethylenimine (bPEI) in fibroblastic lineage cells in serum-based cell culture as shown by both gene and protein analysis. This mTOR knock-down led to an inhibition in fibroblast proliferation by 70% and simultaneous down-regulation in the expression of type I collagen in fibroblasts in vitro. These siRNA/bPEI complexes were released from poly(ethylene glycol) (PEG)-based hydrogel coatings surrounding model polymer implants in a subcutaneous rodent model in vivo. No significant reduction in fibrous capsule thickness and mTOR expression in the foreign body capsules were observed. The siRNA inefficacy in this in vivo implant model was attributed to siRNA dosing limitations in the gel delivery system, and lack of targeting ability of the siRNA complex specifically to fibroblasts. While in vitro data supported mTOR knock-down in fibroblast cultures, in vivo siRNA delivery must be further improved to produce clinically relevant effects on fibrotic encapsulation around implants. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Stress Analysis on the Bone Around Five Different Dental Implants

    DTIC Science & Technology

    2001-10-25

    University of Science and Technology, Tehran, IRAN Abstract- Implantology has a widespread application in dental cases these days. Although the life...System, in Mackinny RV: Endosteal Dental Implant, Mosby Year Book, 1991 [3] Weiss M, Titanium Fiber-Mesh Metal Implant, J. Oral Implantology , 1986...STRESS ANALYSIS ON THE BONE AROUND FIVE DIFFERENT DENTAL IMPLANTS S. M. Rajaai, S. Khorrami-mehr School of mechanical Engineering Iran

  12. Pre-load on oral implants after screw tightening fixed full prostheses: an in vivo study.

    PubMed

    Duyck, J; Van Oosterwyck, H; Vander Sloten, J; De Cooman, M; Puers, R; Naert, I

    2001-03-01

    The fit of implant supported fixed prostheses is said to be of clinical concern because of the rigid fixation of an oral implant in its surrounding bone. The influence of the torque sequence of the set screws during fixation of implant supported fixed full prostheses on the final pre-load was investigated in vitro. No significant effect of the torque sequence of the set screws on the final pre-load was observed. The main objective of this study was to quantify and qualify the pre-load in vivo on implants supporting a fixed full prosthesis. This was performed when the prostheses were supported by all five or six implants and was repeated when the prostheses were supported by only four and three implants. A total of 13 patients with a fixed full implant supported prosthesis were selected. The existing abutments were changed for strain gauged abutments. After tightening the set screws with a torque of 10 N cm, the pre-load conditions were registered. The average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 323 N (43 N), 346 N (59 N), 307 N (60 N) 21 N cm (3 N cm) and 21 N cm (2 N cm), 23 N cm (5 N cm), respectively. In addition, the pre-load was registered after fixation of a machined gold cylinder, as delivered by the manufacturer, on each of the supporting implants, representing the 'optimal fit' situation. The corresponding average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 426 N (36 N), 405 N (40 N), 413 N (46 N) and 8 N cm (1 N cm), 8 N cm (1 N cm), 8 N cm (1 N cm), respectively. The induced axial forces after tightening the prostheses were significantly lower then after tightening the gold cylinder in case of five or six supporting implants (P < 0.02). The induced bending moments after tightening the prostheses were statistically significantly higher (P < 0.0001) then after tightening the gold cylinder in all test conditions (five or six, four or three supporting implants). This study underlines the static load present after screw tightening implant supported fixed full prostheses.

  13. The use of CO(2) laser in the treatment of peri-implantitis.

    PubMed

    Romanos, George; Ko, Hua-Hsin; Froum, Stuart; Tarnow, Dennis

    2009-06-01

    Different techniques have been used for the treatment of peri-implant defects. However, there are always questions about the issue of reosseointegration. The present paper explores the recent literature on the topic of peri-implantitis therapy, and presents a surgical protocol for implant surface decontamination using the CO(2) laser, grafting of the defect, and coverage with a membrane according to a clinical case. The results appear to be promising and may improve the long-term clinical outcomes of failing dental implants.

  14. Computed tomography image-guided surgery in complex acetabular fractures.

    PubMed

    Brown, G A; Willis, M C; Firoozbakhsh, K; Barmada, A; Tessman, C L; Montgomery, A

    2000-01-01

    Eleven complex acetabular fractures in 10 patients were treated by open reduction with internal fixation incorporating computed tomography image guided software intraoperatively. Each of the implants placed under image guidance was found to be accurate and without penetration of the pelvis or joint space. The setup time for the system was minimal. Accuracy in the range of 1 mm was found when registration was precise (eight cases) and was in the range of 3.5 mm when registration was only approximate (three cases). Added benefits included reduced intraoperative fluoroscopic time, less need for more extensive dissection, and obviation of additional surgical approaches in some cases. Compared with a series of similar fractures treated before this image guided series, the reduction in operative time was significant. For patients with complex anterior and posterior combined fractures, the average operation times with and without application of three-dimensional imaging technique were, respectively, 5 hours 15 minutes and 6 hours 14 minutes, revealing 16% less operative time for those who had surgery using image guidance. In the single column fracture group, the operation time for those with three-dimensional imaging application, was 2 hours 58 minutes and for those with traditional surgery, 3 hours 42 minutes, indicating 20% less operative time for those with imaging modality. Intraoperative computed tomography guided imagery was found to be an accurate and suitable method for use in the operative treatment of complex acetabular fractures with substantial displacement.

  15. Animal models for periodontal regeneration and peri-implant responses.

    PubMed

    Kantarci, Alpdogan; Hasturk, Hatice; Van Dyke, Thomas E

    2015-06-01

    Translation of experimental data to the clinical setting requires the safety and efficacy of such data to be confirmed in animal systems before application in humans. In dental research, the animal species used is dependent largely on the research question or on the disease model. Periodontal disease and, by analogy, peri-implant disease, are complex infections that result in a tissue-degrading inflammatory response. It is impossible to explore the complex pathogenesis of periodontitis or peri-implantitis using only reductionist in-vitro methods. Both the disease process and healing of the periodontal and peri-implant tissues can be studied in animals. Regeneration (after periodontal surgery), in response to various biologic materials with potential for tissue engineering, is a continuous process involving various types of tissue, including epithelia, connective tissues and alveolar bone. The same principles apply to peri-implant healing. Given the complexity of the biology, animal models are necessary and serve as the standard for successful translation of regenerative materials and dental implants to the clinical setting. Smaller species of animal are more convenient for disease-associated research, whereas larger animals are more appropriate for studies that target tissue healing as the anatomy of larger animals more closely resembles human dento-alveolar architecture. This review focuses on the animal models available for the study of regeneration in periodontal research and implantology; the advantages and disadvantages of each animal model; the interpretation of data acquired; and future perspectives of animal research, with a discussion of possible nonanimal alternatives. Power calculations in such studies are crucial in order to use a sample size that is large enough to generate statistically useful data, whilst, at the same time, small enough to prevent the unnecessary use of animals. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Retrospective success and survival rates of dental implants placed after a ridge preservation procedure.

    PubMed

    Apostolopoulos, Peter; Darby, Ivan

    2017-04-01

    Ridge preservation is any procedure that takes place at the time of, or shortly after an extraction, to minimise resorption of the ridge and maximise bone formation within the socket. The aim of this project is to investigate the outcome of implant treatment following ridge preservation and compare it to an ungrafted implant control group. Following ethics approval, an electronic and manual search of patient records was conducted, and appropriate cases of implant placement following a ridge preservation procedure were identified. Forty-two patients with 51 implants at ridge-preserved sites were examined by one author (PA) with the following parameters assessed at each implant: pocket probing depth, bleeding on probing, presence/absence of plaque and radiographic bone loss. Clinical and radiographic findings were compared to an ungrafted implant control group and analysed by years in function. There was a 100% survival rate of implants in ridge-preserved sites. In the majority of cases, ridge preservation was performed in the anterior maxilla with a flap raised and the use of deproteinised bovine bone mineral and collagen membrane materials. The mean time in function was 31 (±24) months with a range of 2-102 months. Differences in the mean PPD, BOP, plaque index and radiographic bone loss were not statistically significant between implants at ridge-preserved or ungrafted sites. The overall success rate was around 58% for ungrafted implants and around 51% for implants in ridge-preserved sites. However, this difference was not statistically significant. In this retrospective study, implant placement at ridge-preserved sites was a predictable procedure that led to very high survival rates and similar success rates to implant placement at ungrafted sites. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Immediate Implant-based Prepectoral Breast Reconstruction Using a Vertical Incision

    PubMed Central

    Lind, Jeffrey G.; Hopkins, Elizabeth G.

    2015-01-01

    Background: Ideally, breast reconstruction is performed at the time of mastectomy in a single stage with minimal scarring. However, postoperative complications with direct-to-implant subpectoral reconstruction remain significant. These include asymmetry, flap necrosis, animation deformity, and discomfort. We report on a series of patients who have undergone immediate single-stage prepectoral, implant-based breast reconstruction with a smooth, adjustable saline implant covered with mesh/acellular dermal matrix for support using a vertical mastectomy incision. This technique, when combined with an adjustable implant, addresses the complications related to subpectoral implant placement of traditional expanders. Our follow-up time, 4.6 years (55 months), shows a low risk of implant loss and elimination of animation deformity while also providing patients with a safe and aesthetically pleasing result. Methods: All patients who underwent immediate implant-based prepectoral breast reconstruction using a vertical mastectomy incision as a single-staged procedure were included. Charts were reviewed retrospectively. Adjustable smooth round saline implants and mesh/acellular dermal matrix were used for fixation in all cases. Results: Thirty-one patients (62 breasts) underwent single-staged implant-based prepectoral breast reconstruction using a vertical mastectomy incision. Postoperative complications occurred in 9 patients, 6 of which were resolved with postoperative intervention while only 2 cases resulted in implant loss. Conclusions: There can be significant morbidity associated with traditional subpectoral implant-based breast reconstruction. As an alternative, the results of this study show that an immediate single-stage prepectoral breast reconstruction with a smooth saline adjustable implant, using a vertical incision, in conjunction with mesh/matrix support can be performed with excellent aesthetic outcomes and minimal complications. PMID:26180713

  18. Maxillary sinus floor augmentation using a beta-tricalcium phosphate (Cerasorb) alone compared to autogenous bone grafts.

    PubMed

    Zijderveld, Steven A; Zerbo, Ilara R; van den Bergh, Johan P A; Schulten, Engelbert A J M; ten Bruggenkate, Chris M

    2005-01-01

    A prospective human clinical study was conducted to determine the clinical and histologic bone formation ability of 2 graft materials, a beta-tricalcium phosphate (Cerasorb; Curasan, Kleinostheim, Germany) and autogenous chin bone, in maxillary sinus floor elevation surgery. Ten healthy patients underwent a bilateral (n = 6) or unilateral (n = 4) maxillary sinus floor elevation procedure under local anesthesia. In each case, residual posterior maxillary bone height was between 4 and 8 mm. In cases of bilateral sinus floor elevation, the original bone was augmented with a split-mouth design with 100% beta-tricalcium phosphate on the test side and 100% chin bone on the contralateral control side. The unilateral cases were augmented with 100% beta-tricalcium phosphate. After a healing period of 6 months, ITI full body screw-type implants (Straumann, Waldenburg, Switzerland) were placed. At the time of implant surgery, biopsy samples were removed with a 3.5-mm trephine drill. Sixteen sinus floor elevations were performed. Forty-one implants were placed, 26 on the test side and 15 on the control side. The clinical characteristics at the time of implantation differed, especially regarding clinical appearance and drilling resistance. The increase in height was examined radiographically prior to implantation and was found to be sufficient in all cases. After a mean of nearly 1 year of follow-up, no implant losses or failures had occurred. The promising clinical results of the present study and the lack of implant failures are probably mainly the result of requiring an original bone height of at least 4 mm at the implant location. Although autogenous bone grafting is still the gold standard, according to the clinical results, the preimplantation sinus floor elevation procedure used, which involved a limited volume of beta-tricalcium phosphate, appeared to be a clinically reliable procedure in this patient population.

  19. Multicenter Analysis of Clinical Follow-Ups in Patients with a Star GK Cardiac Valve Replacement for More than One Year.

    PubMed

    Li, Mingwen; Xiao, Yingbin; Chen, Daozhong; Liu, Liming; Ma, Liming; Wang, Pingfan; Jia, Kui; Yang, Kai; Chen, Lin

    2016-05-18

    Star GK valves were widely used in China, and we studied the clinical follow-up results of patients with Star GK valve implants for more than one year.  Clinical data were collected from those patients who had Star GK valve implants for over one year. Patients were divided into three groups: (1) AVR group: received aortic valve replacement surgery. Based on the valve model this group was further sub-divided into two groups: 21A group, and 23A group; (2) MVR group: received mitral valve replacement surgery. Based on the valve model this group was further sub-divided into three groups: 25M group, 27M group, and 29M group; (3) DVR group: received combined replacement surgeries including AVR + MVR. According to postoperative follow-up time these patients were divided into two groups: 1-year group and 3-year group. Follow-up data were collected by telephone, outpatient visits, or correspondence. Clinical data were aggregated by professional data scientists to conduct independent analyses.  959 patients were included in the study following Star GK valve implant. Follow-up after 1 year found that thrombosis occurred in 4 cases, hemorrhage in 15 cases, left heart failure in 13 cases, paravalvular leakage in 5 cases, and death due to cardiac causes in 2 cases.  The long-term efficacy of Star GK valve implants was satisfactory with low incidence of valve-related complications, and following Star GK valve implant, valve and blood were highly compatible and blood component damage was minor. Very low incidence rate of thrombosis was observed following Star GK valve implant, however, attention should be paid to adjust the anticoagulation intensity.

  20. Surface electromyography of myopotential oversensing provoked by simultaneous straining and leftward twisting in a patient with an implantable cardioverter defibrillator.

    PubMed

    Ajiro, Yoichi; Shiga, Tsuyoshi; Shoda, Morio; Hagiwara, Nobuhisa

    2017-03-01

    An important step in diagnosing myopotential oversensing is to confirm its reproducibility using specific provocation maneuvers. Although most maneuvers involve the co-contraction of many muscles, no attempt has been made to assess relevant muscle activities by electromyography. We describe a case with an implantable cardioverter defibrillator (ICD) whose myopotential oversensing was provoked by simultaneous straining and leftward twisting. Simultaneous recordings from real-time ICD telemetry and myopotentials of the rectus abdominis, oblique abdominis, and diaphragm on electromyography during the provocation maneuvers were conducted. It was shown that all three muscles contracted simultaneously during the provocation maneuvers; the diaphragm activity was the main source of noise oversensing, and the twist itself caused oversensing possibly due to the change in the position of the lead. In conclusion, the electromyographic assessment of relevant muscle activities may be useful in assessing each muscle's role and its contribution to myopotential oversensing, especially in a patient whose myopotential oversensing requires complex maneuvers to be provoked.

  1. Prefabricated fibula free flap with dental implants for mandibular reconstruction.

    PubMed

    Pauchet, D; Pigot, J-L; Chabolle, F; Bach, C-A

    2018-03-02

    Free fibula transplant is routinely used for mandibular reconstruction in head and neck cancer. Dental rehabilitation, the objective of mandibular reconstruction, requires the use of dental implants as supports for fixed or removable dentures. Positioning of fibular bone grafts and implants determines implant osseointegration and the possibilities of dental rehabilitation. Prefabrication of a fibula free flap with dental implants prior to harvesting as a free flap can promote implant osseointegration. The position of the implants must then be precisely planned. Virtual surgery and computer-assisted design and prefabrication techniques are used to plan the reconstruction and then reproduce this planning by means of tailored fibula and mandible cutting guides, thereby ensuring correct positioning of fibular bone fragments and implants. The prefabricated fibula free flap technique requires two surgical procedures (prefabrication and flap transfer) and precise preoperative planning. Prefabricated fibula free flap with dental implants, by improving the quality of osseointegration of the implants before flap transfer, extends the possibilities of prosthetic rehabilitation in complex secondary mandibular reconstructions. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  2. Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis.

    PubMed

    Atieh, Momen A; Alsabeeha, Nabeel; Duncan, Warwick J

    2018-05-15

    Clinical trials have suggested that dental implants with a tapered configuration have improved stability at placement, allowing immediate placement and/or loading. The aim of this systematic review and meta-analysis was to evaluate the implant stability of tapered dental implants compared to standard parallel-walled dental implants. Applying the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, randomized controlled trials (RCTs) were searched for in electronic databases and complemented by hand searching. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool and data were analyzed using statistical software. A total of 1199 studies were identified, of which, five trials were included with 336 dental implants in 303 participants. Overall meta-analysis showed that tapered dental implants had higher implant stability values than parallel-walled dental implants at insertion and 8 weeks but the difference was not statistically significant. Tapered dental implants had significantly less marginal bone loss compared to parallel-walled dental implants. No significant differences in implant failure rate were found between tapered and parallel-walled dental implants. There is limited evidence to demonstrate the effectiveness of tapered dental implants in achieving greater implant stability compared to parallel-walled dental implants. Superior short-term results in maintaining peri-implant marginal bone with tapered dental implants are possible. Further properly designed RCTs are required to endorse the supposed advantages of tapered dental implants in immediate loading protocol and other complex clinical scenarios. © 2018 Wiley Periodicals, Inc.

  3. Histologic analysis of a failing three-part dental implant: a human case report.

    PubMed

    Landi, Luca; Manicone, Paolo Francesco; Piccinelli, Stefano; Raia, Roberto

    2005-12-01

    Two failing implants were removed for prosthetic reasons from the maxilla of a 60-year-old woman. The implants were clinically immobile but presented clear signs of peri-implant mucositis and bone destruction. One of the two implants was harvested together with the surrounding bone and analyzed histologically. The implant was threaded and consisted of three distinct components screwed together in a telescopic fashion. Histologically, bone loss reached the fourth thread, while apical to the fourth thread, osseointegration between the host bone and the implant surface was recognizable. The implant parts were not completely seated into each other, and the resulting gap was colonized by host bone. Newly formed alveolar bone penetrated deep into the implant body cavity and appeared similar in nature to the alveolar bone surrounding the implant. Histologic findings are discussed in reference to the ability of such an implant to withstand biomechanical loading over time.

  4. [Postoperative evaluation of surgically treated cases with temporary silicone implant in temporomandibular joint].

    PubMed

    Aoyama, Shigeru; Kino, Koji; Shibuya, Toshihisa; Sato, Fumiaki; Kobayashi, Akiko; Yoshitake, Hiroyuki; Haketa, Tadasu; Amamori, Yoko; Ishikawa, Takayuki; Yoshida, Nahoko; Amagasa, Teruo

    2003-09-01

    We have carried out temporary silicone implants after diskectomies or arthroplasties in temporomandibular joint surgeries to avoid postoperative adhesion and to maintain articular space. We evaluated 19 joints in 15 patients who had received dacron-reinforced silicone implant after silicone sheet removal through follow-up for at least 6 months. The cases included temporomandibular joint disorder (10 joints in 9 patients), psoriatic arthritis (2 joints in 1 patient), ankylosis (4 joints in 3 patients) and synovial chondromatosis (2 joints in 2 patients). On the basis of the criteria of temporomandibular dysfunction for the results, they were classified as bad (4 patients). It is thought that factors other than the implant are related to the bad results in the postoperative evaluation. In this study, lymphadenopathy induced by exfoliated silicone debris could not be confirmed. The temporary silicone implant in the temporomandibular joint was thought to be useful.

  5. Osseocutaneous integration of an intraosseous transcutaneous amputation prosthesis implant used for reconstruction of a transhumeral amputee: case report.

    PubMed

    Kang, Norbert V; Pendegrass, Catherine; Marks, Linda; Blunn, Gordon

    2010-07-01

    Exoprosthetic replacement with an artificial limb is the main option for reconstruction after traumatic amputation of an upper limb. Direct skeletal attachment using an osseointegrated implant improves the ease of fixation of the exoprosthesis to the amputation stump. We now report the use of an intraosseous transcutaneous amputation prosthesis that is designed to achieve osseocutaneous integration. Osseocutaneous integration differs from osseointegration because the aim is to create a stable interface among the implant, the bone, and the soft tissues. This reduces the risk of soft tissue infection and troublesome discharge, which are problems encountered with current osseointegrated implants that focus largely on the bone-implant interface. We describe our experience with an intraosseous transcutaneous amputation prosthesis in a case of transhumeral amputation with 2 years of follow-up. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  6. Mini-implants: alternative for oral rehabilitation of a child with ectodermal dysplasia.

    PubMed

    Mello, Bianca Zeponi Fernandes; Silva, Thiago Cruvinel; Rios, Daniela; Machado, Maria Aparecida Andrade Moreira; Valarelli, Fabrício Pinelli; Oliveira, Thais Marchini

    2015-01-01

    Ectodermal dysplasia is a rare congenital disease that affects several structures of ectodermal origin. The most commonly related oral characteristics are hypodontia, malformed teeth and underdeveloped alveolar ridges. New alternative treatments are needed due to the failure of the conventional prosthesis retention. This case report outlines the oral rehabilitation treatment of a 9-year-old girl with ectodermal dysplasia. The treatment was performed with conventional prosthesis upon mini-implants. The mini-implants provided prosthetic retention. The patient reported a good adaptation of the dental prosthesis and satisfaction with the treatment. The increased self-esteem improved the socialization skills of the girl. In this case report, use of prosthesis with mini-implants was satisfactory for prosthetic retention. However, clinical studies with long-term follow-up are needed to test the mini-implants as an alternative for oral rehabilitation of children with ectodermal dysplasia.

  7. Design Considerations for Developing Biodegradable Magnesium Implants

    NASA Astrophysics Data System (ADS)

    Brar, Harpreet S.; Keselowsky, Benjamin G.; Sarntinoranont, Malisa; Manuel, Michele V.

    The integration of biodegradable and bioabsorbable magnesium implants into the human body is a complex undertaking that faces major challenges. The complexity arises from the fact that biomaterials must meet both engineering and physiological requirements to ensure the desired properties. Historically, efforts have been focused on the behavior of commercial magnesium alloys in biological environments and their resultant effect on cell-mediated processes. Developing causal relationships between alloy chemistry and micro structure, and its effect on cellular behavior can be a difficult and time intensive process. A systems design approach driven by thermodynamics has the power to provide significant contributions in developing the next generation of magnesium alloy implants with controlled degradability, biocompatibility, and optimized mechanical properties, at reduced time and cost. This approach couples experimental research with theory and mechanistic modeling for the accelerated development of materials. The aim of this article is to enumerate this strategy, design considerations and hurdles for developing new magnesium alloys for use as biodegradable implant materials [1].

  8. Morphological characterization of microspheres, films and implants prepared from poly(lactide-co-glycolide) and ABA triblock copolymers: is the erosion controlled by degradation, swelling or diffusion?

    PubMed

    Witt, C; Kissel, T

    2001-05-01

    Erosion of biodegradable parenteral delivery systems (PDS) based on ABA copolymers consisting of poly(L-lactide-co-glycolide) (PLGA) A-blocks attached to polyethylene oxide (PEO) B-blocks, or PLGA is important for the release of macromolecular drugs. The degradation behavior of four types of PDS, namely extruded rods, tablets, films and microspheres, was studied with respect to molecular weight, mass, polymer composition and shape and microstructure of the PDS. For each device the onset time of bulk erosion (t(on)) and the apparent rate of mass loss (k(app)) were calculated. In the case of PLGA, the t(on) was 16.2 days for microspheres, 19.2 days for films and 30.1 days for cylindrical implants and tablets. The k(app) was 0.04 days(-1) for microspheres, 0.09 days(-1) for films, 0.11 days(-1) for implants and 0.10 days(-1) for tablets. The degradation rates were in the same range irrespective of the geometry and the micrographs of eroding PDS demonstrated pore formation; therefore, a complex pore diffusion mechanism seems to control the erosion of PLGA devices. In contrast, PDS based on ABA copolymers showed swelling, followed by a parallel process of molecular weight degradation and polymer erosion, independent of the geometry. The contact angles of ABA films increased either with decreasing PEO content or with increasing chain length of the PEO B-blocks. In summary, the insertion of a hydrophilic B-block leads to an erosion controlled by degradation of ABA copolymers, whereas for PLGA a complex pore diffusion of degradation products controls the rate of bulk erosion.

  9. In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants.

    PubMed

    Rack, A; Rack, T; Stiller, M; Riesemeier, H; Zabler, S; Nelson, K

    2010-03-01

    Micro-gap formation at the implant-abutment interface of two-piece dental implants was investigated in vitro using high-resolution radiography in combination with hard X-ray synchrotron radiation. Images were taken with the specimen under different mechanical loads of up to 100 N. The aim of this investigation was to prove the existence of micro-gaps for implants with conical connections as well as to study the mechanical behavior of the mating zone of conical implants during loading. Synchrotron-based radiography in comparison with classical laboratory radiography yields high spatial resolution in combination with high contrast even when exploiting micro-sized features in highly attenuating objects. The first illustration of a micro-gap which was previously indistinguishable by laboratory methods underlines that the complex micro-mechanical behavior of implants requires further in vitro investigations where synchrotron-based micro-imaging is one of the prerequisites.

  10. Orthodontic management of congenitally missing maxillary lateral incisors: a case report.

    PubMed

    Paduano, Sergio; Cioffi, Iacopo; Rongo, Roberto; Cupo, Antonello; Bucci, Rosaria; Valletta, Rosa

    2014-01-01

    This case report describes the orthodontic treatment of a woman, aged 15 years, with permanent dentition, brachyfacial typology, with congenitally missing maxillary lateral incisors. Multibracket straightwire fixed appliance was used to open the space for dental implant placement, and treat the impaired occlusion. The missing lateral incisors were substituted with oral implants.

  11. [Possibilities of follow-up imaging after implantation of a carbon fiber-reinforced hip prosthesis].

    PubMed

    Krüger, T; Alter, C; Reichel, H; Birke, A; Hein, W; Spielmann, R P

    1998-03-01

    There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. The small sclerotic interface is quite different in comparison to so called "Reactive Lines". In one case of aseptic loosening there was an interposition of soft tissue between prosthesis and bone in MRT and CT. CFRP inaugurates new diagnostic possibilities in aseptic loosening of hip prosthesis and in tumour surgery too.

  12. Refractive Lenticule Implantation for Correction of Ametropia: Case Reports and Literature Review.

    PubMed

    Lazaridis, A; Messerschmidt-Roth, A; Sekundo, W; Schulze, S

    2017-01-01

    The ReLEx® technique allows correction of refractive errors through the creation and extraction of refractive stromal lenticules. Contrary to excimer laser corneal refractive procedures, where the stromal tissue is photoablated, the extracted lenticules obtained with ReLEx® can be preserved. Recent studies and case reports have described autologous re-implantation and allogeneic implantation of refractive lenticules into femtosecond-laser created stromal pockets in order to reverse the refractive outcome of a myopic corneal refractive procedure, correct hyperopia, aphakia, presbyopia and treat keratoconus. The use of stromal lenticules has also been described for therapeutic purposes, with an allogenic lenticule being transplanted under a LASIK flap in order to restore corneal volume and reduce the refractive error in a case of excessive stromal tissue removal after LASIK. This review summarises the results of the latest case reports and studies that describe the implantation of cryopreserved or fresh refractive stromal lenticules and discusses the feasibility, safety and refractive outcomes of the procedure, on the basis of published literature as well as our own experience. Georg Thieme Verlag KG Stuttgart · New York.

  13. Comparison among perfect-C®, zero-P®, and plates with a cage in single-level cervical degenerative disc disease.

    PubMed

    Noh, Sung Hyun; Zhang, Ho Yeol

    2018-01-25

    We intended to analyze the efficacy of a new integrated cage and plate device called Perfect-C for anterior cervical discectomy and fusion (ACDF) to cure single-level cervical degenerative disc disease. We enrolled 148 patients who were subjected to single-level ACDF with one of the following three surgical devices: a Perfect-C implant (41 patients), a Zero-P implant (36 patients), or a titanium plate with a polyetheretherketone (PEEK) cage (71 patients). We conducted a retrospective study to compare the clinical and radiological results among the three groups. The length of the operation, intraoperative blood loss, and duration of hospitalization were significantly lower in the Perfect-C group than in the Zero-P and plate-with-cage groups (P < 0.05). At the last follow-up visit, heterotopic ossification (HO) was not observed in any cases (0%) in the Perfect-C and Zero-P groups but was noted in 21 cases (30%) in the plate-with-cage group. The cephalad and caudal plate-to-disc distance (PDD) and the cephalad and caudal PDD/anterior body height (ABH) were significantly greater in the Perfect-C and Zero-P groups than in the plate-with-cage group (P < 0.05). Subsidence occurred in five cases (14%) in the Perfect-C group, in nine cases (25%) in the Zero-P group, and in 15 cases (21%) in the plate-with-cage group. Fusion occurred in 37 cases (90%) in the Perfect-C group, in 31 cases (86%) in the Zero-P group, and in 68 cases (95%) in the plate-with-cage group. The Perfect-C, Zero-P, and plate-with-cage devices are effective for treating single-level cervical degenerative disc disease. However, the Perfect-C implant has many advantages over both the Zero-P implant and conventional plate-cage treatments. The Perfect-C implant was associated with shorter operation times and hospitalization durations, less blood loss, and lower subsidence rates compared with the Zero-P implant or the titanium plate with a PEEK cage.

  14. “In vitro” Implantation Technique Based on 3D Printed Prosthetic Prototypes

    NASA Astrophysics Data System (ADS)

    Tarnita, D.; Boborelu, C.; Geonea, I.; Malciu, R.; Grigorie, L.; Tarnita, D. N.

    2018-06-01

    In this paper, Rapid Prototyping ZCorp 310 system, based on high-performance composite powder and on resin-high strength infiltration system and three-dimensional printing as a manufacturing method are used to obtain physical prototypes of orthopaedic implants and prototypes of complex functional prosthetic systems directly from the 3D CAD data. These prototypes are useful for in vitro experimental tests and measurements to optimize and obtain final physical prototypes. Using a new elbow prosthesis model prototype obtained by 3D printing, the surgical technique of implantation is established. Surgical implantation was performed on male corpse elbow joint.

  15. A microcontroller-based implantable nerve stimulator used for rats.

    PubMed

    Sha, Hong; Zheng, Zheng; Wang, Yan; Ren, Chaoshi

    2005-01-01

    A microcontroller-based stimulator that can be flexible programmed after it has been implanted into a rat was studied. Programmability enables implanted stimulators to generate customized, complex protocols for experiments. After implantation, a coded light pulse train that contains information of specific identification will unlock a certain stimulator. If a command that changing the parameters is received, the microcontroller will update its flash memory after it affirms the commands. The whole size of it is only 1.6 cubic centimeters, and it can work for a month. The devices have been successfully used in animal behavior experiments, especially on rats.

  16. A Cellular Automata Model of Infection Control on Medical Implants

    PubMed Central

    Prieto-Langarica, Alicia; Kojouharov, Hristo; Chen-Charpentier, Benito; Tang, Liping

    2011-01-01

    S. epidermidis infections on medically implanted devices are a common problem in modern medicine due to the abundance of the bacteria. Once inside the body, S. epidermidis gather in communities called biofilms and can become extremely hard to eradicate, causing the patient serious complications. We simulate the complex S. epidermidis-Neutrophils interactions in order to determine the optimum conditions for the immune system to be able to contain the infection and avoid implant rejection. Our cellular automata model can also be used as a tool for determining the optimal amount of antibiotics for combating biofilm formation on medical implants. PMID:23543851

  17. Effects of hydrogen implantation into GaN

    NASA Astrophysics Data System (ADS)

    Pearton, S. J.; Abernathy, C. R.; Wilson, R. G.; Zavada, J. M.; Song, C. Y.; Weinstein, M. G.; Stavola, M.; Han, J.; Shul, R. J.

    1999-01-01

    Proton implantation in GaN is found to reduce the free carrier density through two mechanisms - first, by creating electron and hole traps at around EC - 0.8 eV and EV + 0.9 eV that lead to compensation in both n- and p-type material, and second, by leading to formation of (AH)° complexes, where A is any acceptor (Mg, Ca, Zn, Be, Cd). The former mechanism is useful in creating high resistivity regions for device isolation, whereas the latter produces unintentional acceptor passivation that is detrimental to device performance. The strong affinity of hydrogen for acceptors leads to markedly different redistribution behavior for implanted H + in n- and p-GaN due to the chemical reaction to form neutral complexes in the latter. The acceptors may be reactivated by simple annealing at ⩾600°C, or by electron injection at 25-150°C that produces debonding of the (AH)° centers. Implanted hydrogen is also strongly attracted to regions of strain in heterostructure samples during annealing, leading to pile-up at epi-epi and epi-substrate interfaces. IR spectroscopy shows that implanted hydrogen also decorates VGa defects in undoped and n-GaN.

  18. Cochlear implantation with hearing preservation yields significant benefit for speech recognition in complex listening environments

    PubMed Central

    Gifford, René H.; Dorman, Michael F.; Skarzynski, Henryk; Lorens, Artur; Polak, Marek; Driscoll, Colin L. W.; Roland, Peter; Buchman, Craig A.

    2012-01-01

    Objective The aim of this study was to assess the benefit of having preserved acoustic hearing in the implanted ear for speech recognition in complex listening environments. Design The current study included a within subjects, repeated-measures design including 21 English speaking and 17 Polish speaking cochlear implant recipients with preserved acoustic hearing in the implanted ear. The patients were implanted with electrodes that varied in insertion depth from 10 to 31 mm. Mean preoperative low-frequency thresholds (average of 125, 250 and 500 Hz) in the implanted ear were 39.3 and 23.4 dB HL for the English- and Polish-speaking participants, respectively. In one condition, speech perception was assessed in an 8-loudspeaker environment in which the speech signals were presented from one loudspeaker and restaurant noise was presented from all loudspeakers. In another condition, the signals were presented in a simulation of a reverberant environment with a reverberation time of 0.6 sec. The response measures included speech reception thresholds (SRTs) and percent correct sentence understanding for two test conditions: cochlear implant (CI) plus low-frequency hearing in the contralateral ear (bimodal condition) and CI plus low-frequency hearing in both ears (best aided condition). A subset of 6 English-speaking listeners were also assessed on measures of interaural time difference (ITD) thresholds for a 250-Hz signal. Results Small, but significant, improvements in performance (1.7 – 2.1 dB and 6 – 10 percentage points) were found for the best-aided condition vs. the bimodal condition. Postoperative thresholds in the implanted ear were correlated with the degree of EAS benefit for speech recognition in diffuse noise. There was no reliable relationship among measures of audiometric threshold in the implanted ear nor elevation in threshold following surgery and improvement in speech understanding in reverberation. There was a significant correlation between ITD threshold at 250 Hz and EAS-related benefit for the adaptive SRT. Conclusions Our results suggest that (i) preserved low-frequency hearing improves speech understanding for CI recipients (ii) testing in complex listening environments, in which binaural timing cues differ for signal and noise, may best demonstrate the value of having two ears with low-frequency acoustic hearing and (iii) preservation of binaural timing cues, albeit poorer than observed for individuals with normal hearing, is possible following unilateral cochlear implantation with hearing preservation and is associated with EAS benefit. Our results demonstrate significant communicative benefit for hearing preservation in the implanted ear and provide support for the expansion of cochlear implant criteria to include individuals with low-frequency thresholds in even the normal to near-normal range. PMID:23446225

  19. A 5-year retrospective case series evaluating Brånemark Integration BioHelix (™) dental implants placed in a private practice by a specialist.

    PubMed

    Thomsson, Mats; Larsson Wexell, Cecilia

    2013-09-01

    To evaluate, in a case series, survival rate and complications of Brånemark Integration BioHelix(™) dental implants, placed according to conventional procedures in patients treated consecutively in a Swedish specialist private practice after 5 years. Eighty-three consecutively-treated patients received 89 final fixed prostheses supported by 310 implants placed according to 'conventional' procedure, i.e. no implants shorter than 10 mm, no immediate post-extraction implants and no bone-grafting procedures. In 70 patients, implants were left to heal submerged, whereas 13 patients were treated according to the one-stage protocol. All implants were incorporated in a prosthetic restoration. Probing was only performed when clinical signs of inflammation were present and this was then evaluated further with intra-oral radiographic examination. Outcome measures were implant survival and prosthetic complications. Five years after implant placement, two fixtures were removed because of loosening. One fixture was lost after 12 months in the lower jaw in one patient and one fixture was lost in the upper jaw in another patient after 3 years, both inserted using the two-stage technique. No other prosthetic complications occurred, giving a 99.3% cumulative survival rate. Brånemark Integration BioHelix(™) dental implants placed according to one- or two-stage procedures in patients in a private practice produced excellent 5-year results. Randomized clinical trials with suitable controls are suggested to confirm these results.

  20. Impression of multiple implants using photogrammetry: description of technique and case presentation.

    PubMed

    Peñarrocha-Oltra, David; Agustín-Panadero, Rubén; Bagán, Leticia; Giménez, Beatriz; Peñarrocha, María

    2014-07-01

    To describe a technique for registering the positions of multiple dental implants using a system based on photogrammetry. A case is presented in which a prosthetic treatment was performed using this technique. Three Euroteknika® dental implants were placed to rehabilitate a 55-year-old male patient with right posterior maxillary edentulism. Three months later, the positions of the implants were registered using a photogrammetry-based stereo-camera (PICcamera®). After processing patient and implant data, special abutments (PICabutment®) were screwed onto each implant. The PICcamera® was then used to capture images of the implant positions, automatically taking 150 images in less than 60 seconds. From this information a file was obtained describing the relative positions - angles and distances - of each implant in vector form. Information regarding the soft tissues was obtained from an alginate impression that was cast in plaster and scanned. A Cr-Co structure was obtained using CAD/CAM, and its passive fit was verified in the patient's mouth using the Sheffield test and the screw resistance test. Twelve months after loading, peri-implant tissues were healthy and no marginal bone loss was observed. The clinical application of this new system using photogrammetry to record the position of multiple dental implants facilitated the rehabilitation of a patient with posterior maxillary edentulism by means of a prosthesis with optimal fit. The prosthetic process was accurate, fast, simple to apply and comfortable for the patient.

  1. Computational assessment of press-fit acetabular implant fixation: the effect of implant design, interference fit, bone quality, and frictional properties.

    PubMed

    Janssen, D; Zwartelé, R E; Doets, H C; Verdonschot, N

    2010-01-01

    Patients suffering from rheumatoid arthritis typically have a poor subchondral bone quality, endangering implant fixation. Using finite element analysis (FEA) an investigation was made to find whether a press-fit acetabular implant with a polar clearance would reduce interfacial micromotions and improve fixation compared with a standard hemispherical design. In addition, the effects of interference fit, friction, and implant material were analysed. Cups were introduced into an FEA model of a human pelvis with simulated subchondral bone plasticity. The models were loaded with a loading configuration simulating two cycles of normal walking, during which contact stresses and interfacial micromotions were monitored. Subsequently, a lever-out simulation was performed to assess the fixation strength of the various cases. A flattened cup with good bone quality produced the lowest interfacial micromotions. Poor bone decreased the fixation strength regardless of the geometry of the cup. Increasing the interference fit of the flattened cup compensated for the loss of fixation strength caused by poor bone quality. In conclusion, a flattened cup did not significantly improve implant fixation over a hemispherical cup in the case of poor bone quality. However, implant fixation can be optimized by increasing interference fit and avoiding inferior frictional properties and low-stiffness implants.

  2. Metastatic Breast Cancer in Medication-Related Osteonecrosis Around Mandibular Implants.

    PubMed

    Favia, Gianfranco; Tempesta, Angela; Limongelli, Luisa; Crincoli, Vito; Piattelli, Adriano; Maiorano, Eugenio

    2015-09-15

    Many authors have considered dental implants to be unrelated to increased risk of medication-related osteonecrosis of the jaw (MRONJ). Nevertheless, more recently, more cases of peri-implant MRONJ (PI-MRONJ) have been described, thus becoming a challenging health problem. Also, metastatic cancer deposits are not infrequently found at peri-implant sites and this may represent an additional complication for such treatments. We present the case of a breast cancer patient with PI-MRONJ, presenting a clinically and radiologically undetected metastasis within the necrotic bone, and highlight the necessity of an accurate histopathological analysis. A 66-year-old female patient, who had received intravenous bisphosphonates for bone breast cancer metastases, came to our attention for a non-implant surgery-triggered PI-MRONJ. After surgical resection of the necrotic bone, conventional and immunohistochemical examinations were performed, which showed breast cancer deposits within the necrotic bone. Cancer patients with metastatic disease, who are undergoing bisphosphonate treatment, may develop unusual complications, including MRONJ, which is a site at risk for hosting additional metastatic deposits that may be clinically and radiologically overlooked. Such risk is increased by previous or concomitant implant procedures. Consequently, clinicians should be prudent when performing implant surgery in cancer patients with advanced-stage disease and consider the possible occurrence of peri-implant metastases while planning adequate treatments in such patients.

  3. Imaging technique for the complete edentulous patient treated conventionally or with mini implant overdenture

    PubMed Central

    Meleşcanu Imre, M; Preoteasa, E; Țâncu, AM; Preoteasa, CT

    2013-01-01

    Rationale. The imaging methods are more and more used in the clinical process of modern dentistry. Once the implant based treatment alternatives are nowadays seen as being the standard of care in edentulous patients, these techniques must be integrated in the complete denture treatment. Aim. The study presents some evaluation techniques for the edentulous patient treated by conventional dentures or mini dental implants (mini SKY Bredent) overdentures, using the profile teleradiography. These offer data useful for an optimal positioning of the artificial teeth and the mini dental implants, favoring to obtain an esthetic and functional treatment outcome. We proposed also a method to conceive a simple surgical guide that allows the prosthetically driven implants placement. Material and method. Clinical case reports were made, highlighting the importance of cephalometric evaluation on lateral teleradiographs in complete edentulous patients. A clinical case that gradually reports the surgical guide preparation (Bredent silicon radio opaque), in order to place the mini dental implants in the best prosthetic and anatomic conditions, was presented. Conclusions. The profile teleradiograph is a useful tool for the practitioner. It allows establishing the optimal site for implant placement, in a good relation with the overdenture. The conventional denture can be easily and relatively costless transformed in a surgical guide used during implant placement. PMID:23599828

  4. Ridge expansion and immediate placement with piezosurgery and screw expanders in atrophic maxillary sites: two case reports.

    PubMed

    Kelly, Andrew; Flanagan, Dennis

    2013-02-01

    Endosseous dental implants may require bone augmentation before implant placement. Herein is described an approach to edentulous ridge expansion with the use of piezosurgery and immediate placement of implants. This may allow for a shortened treatment time and the elimination of donor-site morbidity. Two cases are reported. This technique uses a piezoelectric device to cut the crestal and proximal facial cortices. Space is then created with motorized osteotomes to widen the split ridge. This technique allows for expansion of narrow, anatomically limiting, atrophic ridges, creating space for immediate implant placement. The facial and lingual cortices provide support with vital osteocytes for osteogenesis. The 2 patients presented had adequate bone height for implant placement but narrow edentulous ridges. In patient 1 at site #11, the ridge crest was 3.12 mm thick and was expanded to accept a 4.3 mm × 13 mm implant. The resulting ridge width was 8.88 mm, which was verified using cone beam computerized tomography (CBCT). In patient 2 at site #8 and site #9, the narrow ridge was expanded using the same technique to accept 2 adjacent 3.5 mm × 14 mm implants. The implants were restored to a functional and esthetic outcome.

  5. Revision surgery due to magnet dislocation in cochlear implant patients: an emerging complication.

    PubMed

    Hassepass, Frederike; Stabenau, Vanessa; Maier, Wolfgang; Arndt, Susan; Laszig, Roland; Beck, Rainer; Aschendorff, Antje

    2014-01-01

    To analyze the cause and effect of magnet dislocation in cochlear implant (CI) recipients requiring magnet revision surgery for treatment. Retrospective study. Tertiary referral center. Case reports from 1,706 CI recipients consecutively implanted from January 2000 to December 2011 were reviewed. The number of cases requiring magnet revision surgery was assessed. Revision surgery involving magnet removal or replacement was indicated in 1.23% (21/1,706), of all CI recipients. Magnet dislocation occurring during magnetic resonance tomography (MRI), at 1.5 Tesla (T), with the magnet in place and with the application of compression bandaging around the head, was the main cause for revision surgery in 47.62% (10/21) of the affected cases. All 10 cases were implanted with Cochlear Nucleus cochlear implants. These events occurred, despite adherence to current recommendations of the manufacturer. The present study underlines that MRI examination is the main cause of magnet dislocation. The use of compressive bandaging when using 1.5-T MRI does not eliminate the risk of magnet dislocation. Additional cautionary measures are for required for conditional MRI. We recommend X-ray examination after MRI to determine magnet dislocation and avoid major complications in all cases reporting pain during or after MRI. Additional research regarding silicon magnet pocket design for added retention is needed. Effective communication of guidelines for precautionary measures during MRI examination in CI patients is mandatory for all clinicians involved. MRI in CI recipients should be indicated with caution.

  6. Impression of multiple implants using photogrammetry: Description of technique and case presentation

    PubMed Central

    Peñarrocha-Oltra, David; Agustín-Panadero, Rubén; Bagán, Leticia; Giménez, Beatriz

    2014-01-01

    Aim: To describe a technique for registering the positions of multiple dental implants using a system based on photogrammetry. A case is presented in which a prosthetic treatment was performed using this technique. Study Design: Three Euroteknika® dental implants were placed to rehabilitate a 55-year-old male patient with right posterior maxillary edentulism. Three months later, the positions of the implants were registered using a photogrammetry-based stereo-camera (PICcamera®). After processing patient and implant data, special abutments (PICabutment®) were screwed onto each implant. The PICcamera® was then used to capture images of the implant positions, automatically taking 150 images in less than 60 seconds. From this information a file was obtained describing the relative positions – angles and distances – of each implant in vector form. Information regarding the soft tissues was obtained from an alginate impression that was cast in plaster and scanned. A Cr-Co structure was obtained using CAD/CAM, and its passive fit was verified in the patient’s mouth using the Sheffield test and the screw resistance test. Results and Conclusions: Twelve months after loading, peri-implant tissues were healthy and no marginal bone loss was observed. The clinical application of this new system using photogrammetry to record the position of multiple dental implants facilitated the rehabilitation of a patient with posterior maxillary edentulism by means of a prosthesis with optimal fit. The prosthetic process was accurate, fast, simple to apply and comfortable for the patient. Key words:Dental implants, photogrammetry, dental impression technique, CAD/CAM. PMID:24608216

  7. The patient undergoing implant therapy. Summary and consensus statements. The 4th EAO Consensus Conference 2015.

    PubMed

    Klinge, Björn; Flemming, Thomas; Cosyn, Jan; De Bruyn, Hugo; Eisner, Barbara M; Hultin, Margareta; Isidor, Flemming; Lang, Niklaus P; Lund, Bodil; Meyle, Jürg; Mombelli, Andrea; Navarro, Jose Manuel; Pjetursson, Bjarni; Renvert, Stefan; Schliephake, Henning

    2015-09-01

    The assignment for this working group was to update the existing knowledge regarding factors considered being of special relevance for the patient undergoing implant therapy. This included areas where conflicting opinions exists since long or recently has been expressed, like the role of antibiotic prophylaxis in dental implant surgery and peri-implantitis. Also areas with growing interest and concern such as patient-reported outcome measures (PROMs) and health-economy was included in this review. The literature in the respective areas of interest (antibiotic prophylaxis, peri-implantitis, patient-reported outcome measurements and health-economic aspects) was searched using different strategies for the different papers. Search strategies ranged from a complex systematic review to systematic- and narrative reviews, depending on subject and available literature. All collected material was critically reviewed. Four manuscripts were subsequently presented for group analysis and discussion and plenum discussions and concensus approval. The selected areas were considered to be of key importance and relevance for the patient undergoing implant therapy. The results and conclusions of the review process are presented in the respective papers. The group's conclusions, identified knowledge gaps, directions for future research and concensus statements are presented in this article. The following reviews were available for group discussions and the foundation for subsequent plenary sessions: Lund B, Hultin M, Tranaeus S, Naimi-Akbar A, Klinge B. (2015) Perioperative antibiotics in conjunction with dental implant placement. A complex systematic review. Renvert S & Quirynen M. (2015) Risk indicators for peri-implantitis. A narrative review. De Bruyn H, Raes S, Matthys C, Cosyn J. (2015) The current use of patient centered/reported outcomes in implant dentistry. A systematic review. Beikler T & Flemmig T.F. (2015) Economic evaluation of implant-supported prostheses. A narrative review. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Advanced immediate functional loading: requirements for long-term success in modern implant dentistry.

    PubMed

    Romanos, Georgios E

    2014-01-01

    There are benefits to be derived from the use of advanced surgical protocols in conjunction with immediate functional loading using various dental implant designs and implant-abutment connections. Clinical protocols with simultaneous bone grafting, immediate implant placement, and/or sinus augmentations when a shortened treatment period is needed are included in this report, with the aim of providing understanding of the main protocol characteristics and prerequisites for long-term success in implant dentistry. This article presents three clinical cases that illustrate possibilities for advanced immediate loading using different implant designs. It demonstrates treatment of severe bone defects and the facilitation of placing implants in regenerated bone that can be immediately loaded.

  9. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report

    PubMed Central

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis. PMID:27843356

  10. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report.

    PubMed

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis.

  11. Oral Rehabilitation of a Severely Resorbed Edentulous Maxilla with Screwed-retained Hybrid Denture Using Cresco System: A Case Report

    PubMed Central

    Turkyilmaz, Ilser; Patel, Neal S.; McGlumphy, Edwin A.

    2008-01-01

    Due to the angulation of maxillary bone as the maxillary bone resorption occurs from a buccal to palatal direction, bucco-lingually tilted implant placement is more likely especially in the posterior maxilla. The aim of this paper was to present a case restored by using a maxillary hybrid denture using Cresco method. A 59-year-old woman with an edentulous maxilla and five missing mandibular teeth was referred for implant treatment. Six months after sinus lift operation, four mandibular implants and six maxillary implants were placed. Due to the bucco-lingual tilt of two implants, the Cresco method was chosen to fabricate the metal framework for the maxillary hybrid denture that was delivered four months after implant placement. The main advantages of the Cresco method are a perfectly passive framework fit and corrected screw access holes. All ten implants placed were considered successful at 1-year recall, and no screw access holes were seen in the buccal part of the maxillary acrylic teeth. It was concluded that such screw-retained maxillary hybrid denture using the Cresco method met the esthetic expectations of a highly demanding patient. PMID:19212552

  12. In vivo biocompatibility of new nano-calcium-deficient hydroxyapatite/poly-amino acid complex biomaterials.

    PubMed

    Dai, Zhenyu; Li, Yue; Lu, Weizhong; Jiang, Dianming; Li, Hong; Yan, Yonggang; Lv, Guoyu; Yang, Aiping

    2015-01-01

    To evaluate the compatibility of novel nano-calcium-deficient hydroxyapatite/poly-amino acid (n-CDHA/PAA) complex biomaterials with muscle and bone tissue in an in vivo model. Thirty-two New Zealand white rabbits were used in this study. Biomaterials were surgically implanted into each rabbit in the back erector spinae and in tibia with induced defect. Polyethylene was implanted into rabbits in the control group and n-CDHA/PAA into those of the experimental group. Animals were examined at four different points in time: 2 weeks, 4 weeks, 12 weeks, and 24 weeks after surgery. They were euthanized after embolization. Back erector spinae muscles with the surgical implants were examined after hematoxylin and eosin (HE) staining at these points in time. Tibia bones with the surgical implants were examined by X-ray and scanning electron microscopy (SEM) at these points in time to evaluate the interface of the bone with the implanted biomaterials. Bone tissues were sectioned and subjected to HE, Masson, and toluidine blue staining. HE staining of back erector spinae muscles at 4 weeks, 12 weeks, and 24 weeks after implantation of either n-CDHA/PAA or polyethylene showed disappearance of inflammation and normal arrangement in the peripheral tissue of implant biomaterials; no abnormal staining was observed. At 2 weeks after implantation, X-ray imaging of bone tissue samples in both experimental and control groups showed that the peripheral tissues of the implanted biomaterials were continuous and lacked bone osteolysis, absorption, necrosis, or osteomyelitis. The connection between implanted biomaterials and bone tissue was tight. The results of HE, Masson, toluidine blue staining and SEM confirmed that the implanted biomaterials were closely connected to the bone defect and that no rejection had taken place. The n-CDHA/PAA biomaterials induced differentiation of a large number of chondrocytes. New bone trabecula began to form at 4 weeks after implanting n-CDHA/PAA biomaterials, and lamellar bone gradually formed at 12 weeks and 24 weeks after implantation. Routine blood and kidney function tests showed no significant changes at 2 weeks and 24 weeks after implantation of both biomaterials. n-CDHA/PAA composites showed good compatibility in in vivo model. In this study, n-CDHA/PAA were found to be safe, nontoxic, and biologically active in bone repair.

  13. In vivo biocompatibility of new nano-calcium-deficient hydroxyapatite/poly-amino acid complex biomaterials

    PubMed Central

    Dai, Zhenyu; Li, Yue; Lu, Weizhong; Jiang, Dianming; Li, Hong; Yan, Yonggang; Lv, Guoyu; Yang, Aiping

    2015-01-01

    Objective To evaluate the compatibility of novel nano-calcium-deficient hydroxyapatite/poly-amino acid (n-CDHA/PAA) complex biomaterials with muscle and bone tissue in an in vivo model. Methods Thirty-two New Zealand white rabbits were used in this study. Biomaterials were surgically implanted into each rabbit in the back erector spinae and in tibia with induced defect. Polyethylene was implanted into rabbits in the control group and n-CDHA/PAA into those of the experimental group. Animals were examined at four different points in time: 2 weeks, 4 weeks, 12 weeks, and 24 weeks after surgery. They were euthanized after embolization. Back erector spinae muscles with the surgical implants were examined after hematoxylin and eosin (HE) staining at these points in time. Tibia bones with the surgical implants were examined by X-ray and scanning electron microscopy (SEM) at these points in time to evaluate the interface of the bone with the implanted biomaterials. Bone tissues were sectioned and subjected to HE, Masson, and toluidine blue staining. Results HE staining of back erector spinae muscles at 4 weeks, 12 weeks, and 24 weeks after implantation of either n-CDHA/PAA or polyethylene showed disappearance of inflammation and normal arrangement in the peripheral tissue of implant biomaterials; no abnormal staining was observed. At 2 weeks after implantation, X-ray imaging of bone tissue samples in both experimental and control groups showed that the peripheral tissues of the implanted biomaterials were continuous and lacked bone osteolysis, absorption, necrosis, or osteomyelitis. The connection between implanted biomaterials and bone tissue was tight. The results of HE, Masson, toluidine blue staining and SEM confirmed that the implanted biomaterials were closely connected to the bone defect and that no rejection had taken place. The n-CDHA/PAA biomaterials induced differentiation of a large number of chondrocytes. New bone trabecula began to form at 4 weeks after implanting n-CDHA/PAA biomaterials, and lamellar bone gradually formed at 12 weeks and 24 weeks after implantation. Routine blood and kidney function tests showed no significant changes at 2 weeks and 24 weeks after implantation of both biomaterials. Conclusion n-CDHA/PAA composites showed good compatibility in in vivo model. In this study, n-CDHA/PAA were found to be safe, nontoxic, and biologically active in bone repair. PMID:26504382

  14. Breast implants and possible association with ALCL: A retrospective study including a histological analysis of 296 explanted breast tissues and current literature.

    PubMed

    Kuehlmann, Britta; Prantl, Lukas

    2016-10-05

    To identify a possible connection between anaplastic large cell lymphoma and different types of breast implants. We conducted a retrospective evaluation of 296 breast tissues of 227 women with different breast implant types undergoing surgical revision or explantation between January 2000 and June 2015. Histological and selected immunohistochemical analyses of CD30-&ALK-1-markers of the breast capsules were performed. The womens' average age was 42.91±12.66 years (median: 43.83 years) during implantation and 51.40±11.40 years (median: 52.37 years) during revision or explantation of the implants. Average implant residing time was 8.49±8.90 years (median: 5.83 years). In 51% implantation was for reconstructive, in 48% for aesthetic reasons, in 1% for other reasons. At 59% the main reason for explantation or removal was capsular fibrosis (n = 173). In 296 breast capsules we could not find pathological lymphoma cells according to ALCL, retrospectively. In our study we detected high incidences of various cells in relationship to the implant's type and residing time, which will be published in further articles. We could not find ALCL-cells in breast capsules of explanted or revised breast implants during 2000-2015, retrospectively.There should be a heightened awareness of a possible relationship between the development of cancer and breast implants. To date there are case reports about a possible association between the development of ALCL and breast implants. The number of cases are few and our knowledge of the pathogenesis is little. Further investigation is needed to understand the possible link between breast implants and ALCL found in the breast.

  15. The perception of complex pitch in cochlear implants: A comparison of monopolar and tripolar stimulation.

    PubMed

    Fielden, Claire A; Kluk, Karolina; Boyle, Patrick J; McKay, Colette M

    2015-10-01

    Cochlear implant listeners typically perform poorly in tasks of complex pitch perception (e.g., musical pitch and voice pitch). One explanation is that wide current spread during implant activation creates channel interactions that may interfere with perception of temporal fundamental frequency information contained in the amplitude modulations within channels. Current focusing using a tripolar mode of stimulation has been proposed as a way of reducing channel interactions, minimising spread of excitation and potentially improving place and temporal pitch cues. The present study evaluated the effect of mode in a group of cochlear implant listeners on a pitch ranking task using male and female singing voices separated by either a half or a quarter octave. Results were variable across participants, but on average, pitch ranking was at chance level when the pitches were a quarter octave apart and improved when the difference was a half octave. No advantage was observed for tripolar over monopolar mode at either pitch interval, suggesting that previously published psychophysical advantages for focused modes may not translate into improvements in complex pitch ranking. Evaluation of the spectral centroid of the stimulation pattern, plus a lack of significant difference between male and female voices, suggested that participants may have had difficulty in accessing temporal pitch cues in either mode.

  16. Evaluation of stress distribution of implant-retained mandibular overdenture with different vertical restorative spaces: A finite element analysis

    PubMed Central

    Ebadian, Behnaz; Farzin, Mahmoud; Talebi, Saeid; Khodaeian, Niloufar

    2012-01-01

    Background: Available restorative space and bar height is an important factor in stress distribution of implant-supported overdentures. The purpose of this study was to evaluate the effect of different vertical restorative spaces and different bar heights on the stress distribution around implants by 3D finite element analysis. Materials and Methods: 3D finite element models were developed from mandibular overdentures with two implants in the interforaminal region. In these models, four different bar heights from gingival crest (0.5, 1, 1.5, 2 mm) with 15 mm occlusal plane height and three different occlusal plane heights from gingival crest (9, 12, 15 mm) with 2 mm bar height were analyzed. A vertical unilateral and a bilateral load of 150 N were applied to the central occlusal fossa of the first molar and the stress of bone around implant was analyzed by finite element analysis. Results: By increasing vertical restorative space, the maximum stress values around implants were found to be decreased in unilateral loading models but slightly increased in bilateral loading cases. By increasing bar height from gingival crest, the maximum stress values around implants were found to be increased in unilateral loading models but slightly decreased in bilateral loading cases. In unilateral loading models, maximum stress was found in a model with 9 mm occlusal plane height and 1.5 mm bar height (6.254 MPa), but in bilateral loading cases, maximum stress was found in a model with 15 mm occlusal plane height and 0.5 mm bar height (3.482 MPa). Conclusion: The reduction of bar height and increase in the thickness of acrylic resin base in implant-supported overdentures are biomechanically favorable and may result in less stress in periimplant bone. PMID:23559952

  17. The Statistical Mechanics of Solar Wind Hydroxylation at the Moon, Within Lunar Magnetic Anomalies, and at Phobos

    NASA Technical Reports Server (NTRS)

    Farrell, W. M.; Hurley, D. M.; Esposito, V. J.; Mclain, J. L.; Zimmerman, M. I.

    2017-01-01

    We present a new formalism to describe the outgassing of hydrogen initially implanted by the solar wind protons into exposed soils on airless bodies. The formalism applies a statistical mechanics approach similar to that applied recently to molecular adsorption onto activated surfaces. The key element enabling this formalism is the recognition that the interatomic potential between the implanted H and regolith-residing oxides is not of singular value but possess a distribution of trapped energy values at a given temperature, F(U,T). All subsequent derivations of the outward diffusion and H retention rely on the specific properties of this distribution. We find that solar wind hydrogen can be retained if there are sites in the implantation layer with activation energy values exceeding 0.5eV. We especially examine the dependence of H retention applying characteristic energy values found previously for irradiated silica and mature lunar samples. We also apply the formalism to two cases that differ from the typical solar wind implantation at the Moon. First, we test for a case of implantation in magnetic anomaly regions where significantly lower-energy ions of solar wind origin are expected to be incident with the surface. In magnetic anomalies, H retention is found to be reduced due to the reduced ion flux and shallower depth of implantation. Second, we also apply the model to Phobos where the surface temperature range is not as extreme as the Moon. We find the H atom retention in this second case is higher than the lunar case due to the reduced thermal extremes (that reduces outgassing).

  18. Prevention and management of vascular complications in middle ear and cochlear implant surgery.

    PubMed

    Di Lella, Filippo; Falcioni, Maurizio; Piccinini, Silvia; Iaccarino, Ilaria; Bacciu, Andrea; Pasanisi, Enrico; Cerasti, Davide; Vincenti, Vincenzo

    2017-11-01

    The objective of this study is to illustrate prevention strategies and management of vascular complications from the jugular bulb (JB) and internal carotid artery (ICA) during middle ear surgery or cochlear implantation. The study design is retrospective case series. The setting is tertiary referral university hospital. Patients were included if presented pre- or intraoperative evidence of high-risk anatomical anomalies of ICA or JB during middle ear or cochlear implant surgery, intraoperative vascular injury, or revision surgery after the previous iatrogenic vascular lesions. The main outcome measures are surgical outcomes and complications rate. Ten subjects were identified: three underwent cochlear implant surgery and seven underwent middle ear surgery. Among the cochlear implant patients, two presented with anomalies of the JB impeding access to the cochlear lumen and one underwent revision surgery for incorrect positioning of the array in the carotid canal. Subtotal petrosectomy was performed in all cases. Anomalies of the JB were preoperatively identified in two patients with attic and external auditory canal cholesteatoma, respectively. In a patient, a high and dehiscent JB was found during myringoplasty, while another underwent revision surgery after iatrogenic injury of the JB. A dehiscent ICA complicated middle ear effusion in one case, while in another case, a carotid aneurysm determined a cholesterol granuloma. Rupture of a pseudoaneurysm of the ICA occurred in a child during second-stage surgery and required permanent balloon occlusion without neurological complications. Knowledge of normal anatomy and its variants and preoperative imaging are the basis for prevention of vascular complications during middle ear or cochlear implant surgery.

  19. Accuracy of computer-guided implantation in a human cadaver model.

    PubMed

    Yatzkair, Gustavo; Cheng, Alice; Brodie, Stan; Raviv, Eli; Boyan, Barbara D; Schwartz, Zvi

    2015-10-01

    To examine the accuracy of computer-guided implantation using a human cadaver model with reduced experimental variability. Twenty-eight (28) dental implants representing 12 clinical cases were placed in four cadaver heads using a static guided implantation template. All planning and surgeries were performed by one clinician. All radiographs and measurements were performed by two examiners. The distance of the implants from buccal and lingual bone and mesial implant or tooth was analyzed at the apical and coronal levels, and measurements were compared to the planned values. No significant differences were seen between planned and implanted measurements. Average deviation of an implant from its planning radiograph was 0.8 mm, which is within the range of variability expected from CT analysis. Guided implantation can be used safely with a margin of error of 1 mm. © 2014 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.

  20. Why do dental implants fail? Part I.

    PubMed

    el Askary, A S; Meffert, R M; Griffin, T

    1999-01-01

    Many factors are attributed to failure of the dental implant, either directly or indirectly. The focus of this article is to define the causation of dental implant failure, as well as to present an evaluation of the implant literature regarding etiology, classification, management, and treatment of implant failures. This article will highlight the initial signs of implant failure with a view of some clinical cases in terms of classification and degrees of implant failure. Finally, a dental implant failure checklist is formulated to guide the practitioner in defining the cause of implant failure, be it infective or noninfective, and to establish percentages and frequency of occurrence. The checklist applies to all implant systems and will help to determine the factors responsible for causation and the repair procedures, whether they are at the surgical or restorative phases. The definition of implant failure is set forth in terms of ailing, failing, failed, and surviving implants, and the appropriate treatments and dispositions are outlined.

  1. Periareolar techniques for mammary reduction and elevation.

    PubMed

    de Benito, J; Sanza, I F

    1993-01-01

    Between June 1990 and June 1992 we carried out 56 breast operations: 18 reductions, 32 mastopexies, and 6 implant changes. The surgical techniques used in all cases basically consisted of three phases: the periareolar incision, the creation of the superior pedicle with two medial and lateral flaps, and the "anchoring," crossed by both flaps in order to hold up the mammary gland. The diameter of the "doughnut" of skin that we had to deepidermize varied between 5 and 15 cm, thus raising the nipple-areola complex by as much as 10 cm. The volume of tissue removed from the hypertrophic breast ranged from 70 to 520 g. In 24 of the 32 mastopexies, the use of a silicone implant was necessary in order to provide greater volume, texture, and better mammary contour. In these cases the size of the prostheses varied between 120 and 300 cc. All patients completed the postop followup in the normal way. Only three patients suffered a slight dehiscence of the periareolar suture, which was solved within a few days of the operation by means of a Friedreich. The periareolar cutaneous pleats and the hardness of the breast gradually disappeared, as predicted, within a period of 3-4 months; afterward the breast looked perfectly natural.

  2. Multidisciplinary management including periodontics, orthodontics, implants, and prosthetics for an adult.

    PubMed

    Pinho, Teresa; Neves, Manuel; Alves, Célia

    2012-08-01

    This article describes the complex dental treatment of an adult patient with multiple missing teeth, mild chronic periodontitis, and a malocclusion with a cant of the occlusal plane. After periodontal treatment, titanium implants and a miniscrew were placed to correct the occlusal plane canting with orthodontic treatment. Prosthodontic treatment was completed by using osseointegrated implants to replace the missing teeth. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  3. C1-C2 arthrodesis after spontaneous Propionibacterium acnes spondylodiscitis: Case report and literature analysis

    PubMed Central

    di Russo, Paolo; Tascini, Carlo; Benini, Maria Elena; Martini, Carlotta; Lepori, Paolo

    2018-01-01

    Background: Propionibacterium acnes (P. acnes) is a microaerophilic anaerobic Gram-positive rod responsible for acne vulgaris. Although it is often considered to be a skin contaminant, it may act as a virulent agent in implant-associated infections. Conversely, spontaneous infectious processes have been rarely described. Case Description: Here, we describe a 43-year-old female with C1-C2 spondylodiscitis attributed to P. acnes infection. Despite long-term antibiotic treatment, computed tomography demonstrated erosion of the C1 and C2 vertebral complex that later warranted a fusion. One year postoperatively, the patient was asymptomatic. Conclusions: Clinical knowledge of P. acnes virulence in spontaneous cervical spondylodiscitis allows early diagnosis, which is necessary to prevent or reduce complications such as cervical deformity with myelopathy or mediastinitis. PMID:29497567

  4. Bilateral Ocular Decompression Retinopathy after Ahmed Valve Implantation for Uveitic Glaucoma

    PubMed Central

    Flores-Preciado, Javier; Ancona-Lezama, David Arturo; Valdés-Lara, Carlos Andrés; Díez-Cattini, Gian Franco; Coloma-González, Itziar

    2016-01-01

    Case Report We report the case of a 29-year-old man who underwent Ahmed valve implantation in both eyes as treatment for uveitic glaucoma, subsequently presenting with bilateral ocular decompression retinopathy in the postoperative period. Discussion Ocular decompression retinopathy is a rare complication of filtering surgery in patients with glaucoma; however, the course is benign in most cases, with spontaneous resolution of bleedings and improvement of visual acuity. PMID:27920718

  5. Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.

    PubMed

    Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan

    2011-01-01

    With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Spontaneous extrusion of a stainless steel glaucoma drainage implant (Ex-PRESS).

    PubMed

    Tavolato, M; Babighian, S; Galan, A

    2006-01-01

    To report a case of spontaneous extrusion of a stainless steel glaucoma drainage implant (Ex-PRESS). An Ex-PRESS was implanted under the conjunctiva in a 76-year-old man with primary open-angle glaucoma. Two years after implantation, the Ex-Press extruded spontaneously. Despite this adverse event, there was no increase in intraocular pressure. This is the first report of spontaneous extrusion of an Ex-PRESS device. Implanting the device under a scleral flap should be considered to avoid adverse events such as extrusion or conjunctival erosion.

  7. [Stent implantation in the treatment of pharynx anastomotic stenosis after cervical esophageal resection: a case report].

    PubMed

    Zang, Chuanshan; Sun, Jian; Sun, Yan

    2016-03-01

    We report the treatment of one patient with pharynx anastomotic stenosis after cervical esophagealresection by stent implantation. The patient suffered from serious pharynx anastomotic stenosis after gastric-pha-ryngeal anastomosis. After balloon-dilatation,a domestic self-expanding Z-stents was implanted in the stricture ofthe esophagus under the X-rays. After stent implantation, the patient has been leading a normal life for threeyears. Balloon dilatation and stent implantation is an effective and safe method in the treatment of patients withpharynx anastomotic stenosis.

  8. Dislocation of cochlear implant magnet as a complication following MRI.

    PubMed

    Murtojärvi, Sarita; Salonen, Jaakko

    According to current best knowledge, an MRI scan can be performed for patients with cochlear implants. The warnings and recommendations of the implant manufacturers must be followed strictly to prevent complications, such as overheating, migration or demagnetization of the magnet in the implant. We report on a case of cochlear implant magnet dislocation as a complication for an MRI scan. The patient had a tight bandage around the head to hold the magnet in place as recommended by the manufacturer, but apparently the bandage was not in the correct place.

  9. Prosthetic Consideration in Implant-supported Prosthesis: A Review of Literature

    PubMed Central

    Gowd, Manga Snigdha; Shankar, Thatapudi; Ranjan, Rajeev; Singh, Arpita

    2017-01-01

    Modern dentistry has changed tremendously with implant therapy. For the successful implant therapy, making a proper treatment plan considering both surgical and prosthetic part in mind is the key of success. Often practitioners tend to create a treatment plan overlooking the basic principles of prosthetic part. This present review has discussed various prosthetic consideration of implant-supported prosthesis. A step-by-step detailed prosthetic option with their indications has been discussed to help all dental implant practitioners in making of an optimal treatment plan for each case. PMID:28713760

  10. Strategic Use of Microscrews for Enhancing the Accuracy of Computer-Guided Implant Surgery in Fully Edentulous Arches: A Case History Report.

    PubMed

    Lee, Du-Hyeong

    Implant guide systems can be classified by their supporting structure as tooth-, mucosa-, or bone-supported. Mucosa-supported guides for fully edentulous arches show lower accuracy in implant placement because of errors in image registration and guide positioning. This article introduces the application of a novel microscrew system for computer-aided implant surgery. This technique can markedly improve the accuracy of computer-guided implant surgery in fully edentulous arches by eliminating errors from image fusion and guide positioning.

  11. Scientific Fundamentals and Technological Development of Novel Biocompatible/Corrosion Resistant Ultrananocrystalline Diamond (UNCD) Coating Enabling Next Generation Superior Metal-Based Dental Implants

    NASA Astrophysics Data System (ADS)

    Kang, Karam

    Current Ti-based dental implants exhibit failure (2-10%), due to various mechanisms, including chemical corrosion of the surface of the TiO2 naturally covered Ti-based implants. This thesis focused on developing a unique biocompatible/bio-inert/corrosion resistant/low cost Ultrananocrystalline Diamond (UNCD) coating (with 3-5 nm grain size) for encapsulation of Tibased micro-implants to potentially eliminate the corrosion/mechanical induced failure of current commercial Ti-based dental implants. Microwave Plasma Chemical Vapor Deposition (MPCVD) and Hot Filament Chemical Vapor Deposition (HFCVD) processes were used to grow UNCD coatings. The surface topography and chemistry of UNCD coatings were characterized using scanning electron microscopy (SEM), Raman, and X-ray photoelectron spectroscopies (XPS) respectively. In conclusion, this thesis contributed to establish the optimal conditions to grow UNCD coatings on the complex 3-D geometry of Ti-based micro-implants, with geometry similar to real implants, relevant to developing UNCD-coated Ti-based dental implants with superior mechanical/chemical performance than current Ti-based implants.

  12. Periodontal tissue regeneration by combined implantation of adipose tissue-derived stem cells and platelet-rich plasma in a canine model.

    PubMed

    Tobita, Morikuni; Uysal, Cagri A; Guo, Xin; Hyakusoku, Hiko; Mizuno, Hiroshi

    2013-12-01

    One goal of periodontal therapy is to regenerate periodontal tissues. Stem cells, growth factors and scaffolds and biomaterials are vital for the restoration of the architecture and function of complex tissues. Adipose tissue-derived stem cells (ASCs) are an ideal population of stem cells for practical regenerative medicine. In addition, platelet-rich plasma (PRP) can be useful for its ability to stimulate tissue regeneration. PRP contains various growth factors and may be useful as a cell carrier in stem cell therapies. The purpose of this study was to determine whether a mixture of ASCs and PRP promoted periodontal tissue regeneration in a canine model. Autologous ASCs and PRP were implanted into areas with periodontal tissue defects. Periodontal tissue defects that received PRP alone or non-implantation were also examined. Histologic, immunohistologic and x-ray studies were performed 1 or 2 months after implantation. The amount of newly formed bone and the scale of newly formed cementum in the region of the periodontal tissue defect were analyzed on tissue sections. The areas of newly formed bone and cementum were greater 2 months after implantation of ASCs and PRP than at 1 month after implantation, and the radiopacity in the region of the periodontal tissue defect increased markedly by 2 months after implantation. The ASCs and PRP group exhibited periodontal tissue with the correct architecture, including alveolar bone, cementum-like structures and periodontal ligament-like structures, by 2 months after implantation. These findings suggest that a combination of autologous ASCs and PRP promotes periodontal tissue regeneration that develops the appropriate architecture for this complex tissue. Copyright © 2013 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  13. A glass fiber-reinforced composite - bioactive glass cranioplasty implant: A case study of an early development stage implant removed due to a late infection.

    PubMed

    Posti, Jussi P; Piitulainen, Jaakko M; Hupa, Leena; Fagerlund, Susanne; Frantzén, Janek; Aitasalo, Kalle M J; Vuorinen, Ville; Serlo, Willy; Syrjänen, Stina; Vallittu, Pekka K

    2015-03-01

    This case study describes the properties of an early development stage bioactive glass containing fiber-reinforced composite calvarial implant with histology that has been in function for two years and three months. The patient is a 33-year old woman with a history of substance abuse, who sustained a severe traumatic brain injury later unsuccessfully treated with an autologous bone flap and a custom-made porous polyethylene implant. She was thereafter treated with developmental stage glass fiber-reinforced composite - bioactive glass implant. After two years and three months, the implant was removed due to an implant site infection. The implant was analyzed histologically, mechanically, and in terms of chemistry and dissolution of bioactive glass. Mechanical integrity of the load bearing fiber-reinforced composite part of the implant was not affected by the in vivo period. Bioactive glass particles demonstrated surface layers of hydroxyapatite like mineral and dissolution, and related increase of pH was considerably less after two and three months period than that for fresh bioactive glass. There was a difference in the histology of the tissues inside the implant areas near to the margin of the implant that absorbed blood during implant installation surgery, showed fibrous tissue with blood vessels, osteoblasts, collagenous fibers with osteoid formation, and tiny clusters of more mature hard tissue. In the center of the implant, where there was less absorbed blood, only fibrous tissue was observed. This finding is in line with the combined positron emission tomography - computed tomography examination with (18F)-fluoride marker, which demonstrated activity of the mineralizing bone by osteoblasts especially at the area near to the margin of the implant 10 months after implantation. Based on these promising reactions found in the bioactive glass containing fiber-reinforced composite implant that has been implanted for two years and three months, calvarial reconstruction with the presented material appears to be a feasible method. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. [Complications of intrathecal baclofen therapy].

    PubMed

    Paskhin, D L; Dekopov, A V; Tomsky, A A; Isagulyan, E D; Salova, E M

    To analyze complications of intrathecal baclofen therapy and identify high-risk groups. We implanted 52 pumps to spastic patients for chronic intrathecal baclofen infusion. Two groups of patients were distinguished: 23 patients with spinal spasticity (group 1) and 29 patients with cerebral spasticity (group 2). The mean patient age was 37.2±14.6 years in group 1 and 17.3±10.3 years in group 2. Surgery was performed according to a standard procedure. A Medstream (Codman) pump was implanted in 10 cases, and a Synchromed II (Medtronic) pump was implanted in the remaining 42 cases. Complications developed in 12 (23%) patients. We divided complications into 3 groups: baclofen underdose, baclofen overdose, and others. Insufficiency of intrathecal therapy was observed in 7 cases, which was caused by catheter migration (5 cases) and pump dysfunction (2 cases). In one case, baclofen overdose was observed after air travel. Other complications included 4 cases of persistent peri-implant seroma and infectious complications. Groups with a high risk of complications were identified based on an analysis of the results. Patients with severe dystonia of the trunk muscles have an increased risk of spinal catheter migration. Pronounced communicating hydrocephalus is associated with the risk of cerebrospinal fluid leak through a catheter shaft channel. Weakness of the axial musculature can lead to progression of scoliotic deformity. In some cases, chronic intrathecal baclofen therapy can be accompanied by various complications. This technique should be carefully used in patients from high-risk groups.

  15. Financial impact of spinal cord stimulation on the healthcare budget: a comparative analysis of costs in Canada and the United States.

    PubMed

    Kumar, Krishna; Bishop, Sharon

    2009-06-01

    Many institutions with spinal cord stimulation (SCS) programs fail to realize that besides the initial implantation cost, budgetary allocation must be made to address annual maintenance costs as well as complications as they arise. Complications remain the major contributing factor to the overall expense of SCS. The authors present a formula that, when applied, provides a realistic representation of the actual costs necessary to implant and maintain SCS systems in Canada and the US. The authors performed a retrospective analysis of 197 cases involving SCS (161 implanted and 36 failed trial stimulations) between 1995 and 2006. The cost of patient workup, initial implantation, annual maintenance, and resources necessary to resolve complications were assessed for each case and a unit cost applied. The total cost allocated for each case was determined by summing across healthcare resource headings. Using the same parameters, the unit cost was calculated in both Canadian (CAD) and US dollars (USD) at 2007 prices. The cost of implanting a SCS system in Canada is $21,595 (CAD), in US Medicare $32,882 (USD), and in US Blue Cross Blue Shield (BCBS) $57,896 (USD). The annual maintenance cost of an uncomplicated case in Canada is $3539 (CAD), in US Medicare $5071 (USD), and in BCBS $7277 (USD). The mean cost of a complication was $5191 in Canada (range $136-18,837 [CAD]). In comparison, in the US the figures were $9649 (range $381-28,495) for Medicare and $21,390 (range $573-54,547) for BCBS (both USD). Using these calculations a formula was derived as follows: the annual maintenance cost (a) was added to the average annual cost per complication per patient implanted (b); the sum was then divided by the implantation cost (c); and the result was multiplied by 100 to obtain a percentage (a + b / c x 100). To make this budgetary cap universally applicable, the results from the application of the formula were averaged, resulting in an 18% premium. For budgeting purposes the institution should first calculate the initial implantation costs that then can be "grossed up" by 18% per annum. This amount of 18% should be in addition to the implantation costs for the individual institution for new patients, as well as for each actively managed patient. This resulting amount will cover the costs associated with annual maintenance and complications for every actively managed patient. As the initial cost of implantation in any country reflects their current economics, the formula provided will be applicable to all implanters and policy makers alike.

  16. Pacemakers and implantable cardioverter-defibrillators in pediatric patients.

    PubMed

    Silka, Michael J; Bar-Cohen, Yaniv

    2006-11-01

    The use of pacemakers and implantable cardioverter-defibrillators (ICDs) in infants, children, and patients with congenital heart disease presents unique challenges and considerations. They include uncommon indications for device implantation, innovative approaches to lead implantation and configuration, and age-dependent and disease-specific aspects of device programming. In this review, the current indications for pacemaker and ICD implantation in young patients are discussed, followed by consideration of the approaches to lead and device placement in very small patients and those with complex congenital heart disease, in whom unique problems may be encountered. The limitations of programmability of current pacemakers and ICDs when used in young patients are discussed, followed by an analysis of long-term device follow-up and potential late complications.

  17. Long-Term Asymmetric Hearing Affects Cochlear Implantation Outcomes Differently in Adults with Pre- and Postlingual Hearing Loss

    PubMed Central

    Boisvert, Isabelle; McMahon, Catherine M.; Dowell, Richard C.; Lyxell, Björn

    2015-01-01

    In many countries, a single cochlear implant is offered as a treatment for a bilateral hearing loss. In cases where there is asymmetry in the amount of sound deprivation between the ears, there is a dilemma in choosing which ear should be implanted. In many clinics, the choice of ear has been guided by an assumption that the reorganisation of the auditory pathways caused by longer duration of deafness in one ear is associated with poorer implantation outcomes for that ear. This assumption, however, is mainly derived from studies of early childhood deafness. This study compared outcomes following implantation of the better or poorer ear in cases of long-term hearing asymmetries. Audiological records of 146 adults with bilateral hearing loss using a single hearing aid were reviewed. The unaided ear had 15 to 72 years of unaided severe to profound hearing loss before unilateral cochlear implantation. 98 received the implant in their long-term sound-deprived ear. A multiple regression analysis was conducted to assess the relative contribution of potential predictors to speech recognition performance after implantation. Duration of bilateral significant hearing loss and the presence of a prelingual hearing loss explained the majority of variance in speech recognition performance following cochlear implantation. For participants with postlingual hearing loss, similar outcomes were obtained by implanting either ear. With prelingual hearing loss, poorer outcomes were obtained when implanting the long-term sound-deprived ear, but the duration of the sound deprivation in the implanted ear did not reliably predict outcomes. Contrary to an apparent clinical consensus, duration of sound deprivation in one ear has limited value in predicting speech recognition outcomes of cochlear implantation in that ear. Outcomes of cochlear implantation are more closely related to the period of time for which the brain is deprived of auditory stimulation from both ears. PMID:26043227

  18. Implants and Ethnocide: Learning from the Cochlear Implant Controversy

    ERIC Educational Resources Information Center

    Sparrow, Robert

    2010-01-01

    This paper uses the fictional case of the "Babel fish" to explore and illustrate the issues involved in the controversy about the use of cochlear implants in prelinguistically deaf children. Analysis of this controversy suggests that the development of genetic tests for deafness poses a serious threat to the continued flourishing of Deaf…

  19. Retrospective chart analysis on survival rate of fixtures installed at the tuberosity bone for cases with missing unilateral upper molars: a study of 7 cases.

    PubMed

    Park, Young-Jin; Cho, Sung-Am

    2010-06-01

    To evaluate the survival rate of implants placed in the maxillary tuberosity region using the fixed prosthesis in partially edentulous cases. Of implant-treated patients who visited Kyung Pook National University Hospital, 7 partially edentulous patients (2 male and 5 female; mean age, 52.3 years; range, approximately 43 to 65) were selected according to the following criteria: 1) less than 3-mm thickness alveolar bone reaming at the first molar area and 2) 1 to 2 fixture premolars, with the additional implant at the maxillary tuberosity region. For the control group, patients who had nontuberosity areas were selected. After 1 to 7 years, marginal bone level, fixture mobility, and radiolucency of tuberosity fixtures of the fixed prostheses were evaluated by digital panorama (Starpacs, Infinitt, Seoul, Korea). None of the fixtures of the tuberosity-installed implants for 1 to 7 years failed. The marginal bone level around the implants of the maxillary tuberosity 1 to 6 years (average 3.4 years) after the final prostheses was approximately 0.6 to 1.3 mm, with an average of 0.94 mm. The fixture installation at the maxillary tuberosity using the unilateral partially edentulous implant-fixed prosthesis would be a clinically acceptable treatment module. 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Full arch rehabilitation in severe maxillary atrophy with palatal approach implant placement: a case report

    PubMed Central

    BASSI, M. ANDREASI; LOPEZ, M.A.; ANDRISANI, C.; ORMANIER, Z.; GARGARI, M.

    2016-01-01

    SUMMARY Purpose The edentulous severely atrophic maxilla, as consequence of alveolar bone resorption and pneumatisation of the maxillary sinus, represents a serious limitation to the implant rehabilitation. Implants insertion via palatal approach (PA), in combination with relatively minimally invasive techniques aimed at increasing bone volume without the use of autologous bone harvesting is a valid alternative among the options for the rehabilitation of the upper jaw. Clinical case In a 70-year-old female, with a severe maxillary atrophy, 6 spiral taper implants were placed with the PA, combined with the bilateral transcrestal elevation of both the sinus floors and nasal cavities; a further GBR, with resorbable pericardium membrane covering a termoplastic allograft associated to a xenograft, was performed. The second stage was performed after 6 months. Implant prosthetic functionalization was carried out in 4 months by placing the removable prosthesis in direct contact with the healing cup screws. After that period the case was finalized with a hybrid prosthesis. Clinical and radiographic follow-ups were carried out at 6 months and at one year after prosthetic finalization, during which no pathological signs were recorded. Conclusions The PA implant insertion described by the Authors, combined with bone augmentation procedures, performed in the same stage, may represent a valid and reliable solution to rehabilitate maxillary edentulous patients. PMID:28042439

  1. Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well

    PubMed Central

    Chang, Glenn Hsuan-Chen; Tian, Chen; Hung, Yuen-Siang

    2011-01-01

    Purpose: An integrated fixture mount/impression coping/ temporary abutment can provide many advantages for immediate loading of dental implants, such as simpler procedure, less chair time, cost reduction, and comfort for the patients. Materials and Methods: A newly designed dental implant fixture mount (DIFMA) can be used as an impression coping for taking an immediate impression. An immediate load provisional prosthesis can then be fabricated shortly after implant placement to immediately load the implants. This fixture mount can also serve as a temporary abutment for immediate chair-side fabrication of provisional prosthesis. Two clinical cases are presented. Results: A clinical case utilizing the fixture mount abutment (DIFMA)/implant assembly is presented. The precision of fitting between the impression copings and implants is secured with this system. The chair time for taking an immediate impression is greatly reduced. Less cost for the restoration is provided and patient comfort is delivered. Conclusions: More patient satisfaction can be conferred by employing the fixture mount in the process of immediate impression taking and as an immediate provisional abutment. PMID:22090763

  2. Reconstruction of a Severely Atrophied Alveolar Ridge by Computer-Aided Gingival Simulation and 3D-Printed Surgical Guide: A Case Report.

    PubMed

    Song, In-Seok; Lee, Mi-Ran; Ryu, Jae-Jun; Lee, Ui-Lyong

    Dental implants positioned in severely atrophied anterior maxillae require esthetic or functional compromises. This case report describes the rehabilitation of a severely atrophied alveolar ridge with a three-dimensional (3D) computer-aided design/computer-aided manufacture (CAD/CAM) surgical guide. A 50-year-old woman had a severely atrophied anterior maxilla with unfavorably positioned dental implants. Functional and esthetic prosthodontic restoration was difficult to achieve. An anterior segmental osteotomy was planned to reposition the dental implants. A 3D surgical guide was designed for precise relocation of the segment. The surgical guide firmly grasped the impression copings of the dental implants, minimizing surgical errors. Three-dimensional gingival simulation was used preoperatively to estimate the appropriate position of the gingiva. Rigid fixation to the surrounding bone allowed immobilization of the implant-bone segment. Satisfactory esthetic and functional outcomes were attained 6 months after surgery. Finally, a severely atrophied alveolar ridge with unfavorably positioned dental implants was recovered with minimal esthetic and functional deterioration using gingival simulation and a 3D CAD/CAM surgical guide.

  3. The influence of the attachment type and implant number supporting mandibular overdentures on stress distribution: an in vitro study, part I.

    PubMed

    Arat Bilhan, Selda; Bilhan, Hakan; Bozdag, Ergun; Sunbuloglu, Emin; Baykasoglu, Cengiz; Kutay, Omer

    2013-02-01

    The main goal of this study was to compare the stress distribution of mandibular overdentures (OVD) with different numbers of supporting implants and single versus splinted attachment types. Four different biting situations were simulated for the 2-, 3-, and 4-implant retentive anchor as well as bar attachment OVDs on a formalin-fixed cadaver mandible, and strains were recorded under vertical loading of 100 N. The calculated von Mises values from measured strains in all measurement sites and loading conditions for nonsplinted attachments (retentive anchor) were higher than splinted (bar) attachments. It may be concluded that in cases with low quality and quantity of bone, the increase in number of implants and the use of a splinted attachment should be preferred to reduce forces emerging around the implants during function. The use of 2 single attachments in cases with good bone quality and ideal size implants still seems to be a safe and sufficient solution for the treatment of mandibular edentulism with OVDs.

  4. The efficacy of Ahmed glaucoma valve drainage devices in cases of adult refractory glaucoma in Indian eyes

    PubMed Central

    Parihar, Jitendra K S; Vats, Devendra P; Maggon, Rakesh; Mathur, Vijay; Singh, Anirudh; Mishra, Sanjay K

    2009-01-01

    Aim: To evaluate the efficacy of Ahmed glaucoma valve (AGV) drainage devices in cases of adult refractory glaucoma in Indian eyes. Settings and Design: Retrospective interventional case series study. Materials and Methods: Fifty two eyes of 32 patients of refractory glaucoma in the age group of 35 to 60 years who underwent AGV implantation with or without concomitant procedures from January 2003 to Jan 2007 were studied. Of these, 46 eyes (88%) had undergone filtering surgery earlier whereas remaining eyes underwent primary AGV implantation following failure of maximal medical therapy. The follow up ranged between 12 months to 48 months Results: Eighteen eyes (35%) had undergone phacoemulsification with AGV implantation, penetrating keratoplasty (PK) with AGV and intraocular lens (IOL) implantation in 13 eyes (25%), AGV over preexisting IOL in eight eyes (15%). AGV implantation alone was done in six (11%) eyes. Anterior chamber (AC) reconstruction with secondary IOL and AGV was performed in the remaining eyes. The mean intra ocular pressure (IOP) decreased from 36.3 ± 15.7 mm Hg to 19.6 ± 9.2 mm Hg. Complete success as per criteria was achieved in 46 eyes (88%). None of the eyes had failure to maintain IOP control following AGV. Conclusion: The AGV resulted in effective and sustained control of IOP in cases of adult refractory glaucoma in intermediate follow up. PMID:19700871

  5. Orthodontic Management of Congenitally Missing Maxillary Lateral Incisors: A Case Report

    PubMed Central

    Rongo, Roberto; Cupo, Antonello; Valletta, Rosa

    2014-01-01

    This case report describes the orthodontic treatment of a woman, aged 15 years, with permanent dentition, brachyfacial typology, with congenitally missing maxillary lateral incisors. Multibracket straightwire fixed appliance was used to open the space for dental implant placement, and treat the impaired occlusion. The missing lateral incisors were substituted with oral implants. PMID:24711929

  6. [Implantation of intraocular lenses in the ciliary sulcus].

    PubMed

    Schulze, S; Bertelmann, T; Sekundo, W

    2014-04-01

    Implantation of an intraocular lens (IOL) into the ciliary sulcus is the second most common implantation site after the regular capsular bag (in the bag) placement of an IOL. Although mainly not primarily intended, it is very often used in both complicated cataract surgery and secondary implantation due to IOL dislocation or aphakia. In most cases stable positioning is possible, especially when using optic capture techniques. A variety of difficulties can occur with sulcus implantation depending on the anatomical and surgical conditions present at the time of implantation. The most anterior position of the sulcus lense has to be considered for calculation of the refractive power of the IOL.

  7. Three-Dimensional Finite Element Analysis on Stress Distribution of Internal Implant-Abutment Engagement Features.

    PubMed

    Cho, Sung-Yong; Huh, Yun-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    To investigate the stress distribution in an implant-abutment complex with a preloaded abutment screw by comparing implant-abutment engagement features using three-dimensional finite element analysis (FEA). For FEA modeling, two implants-one with a single (S) engagement system and the other with a double (D) engagement system-were placed in the human mandibular molar region. Two types of abutments (hexagonal, conical) were connected to the implants. Different implant models (a single implant, two parallel implants, and mesial and tilted distal implants with 1-mm bone loss) were assumed. A static axial force and a 45-degree oblique force of 200 N were applied as the sum of vectors to the top of the prosthetic occlusal surface with a preload of 30 Ncm in the abutment screw. The von Mises stresses at the implant-abutment and abutment-screw interfaces were measured. In the single implant model, the S-conical abutment type exhibited broader stress distribution than the S-hexagonal abutment. In the double engagement system, the stress concentration was high in the lower contact area of the implant-abutment engagement. In the tilted implant model, the stress concentration point was different from that in the parallel implant model because of the difference in the bone level. The double engagement system demonstrated a high stress concentration at the lower contact area of the implant-abutment interface. To decrease the stress concentration, the type of engagement features of the implant-abutment connection should be carefully considered.

  8. Histologic and Radiographic Analysis of Nonhealing Extraction Sockets Treated with Bio-Oss Collagen After a 4-Month Healing Period: A Prospective Descriptive Study in Humans.

    PubMed

    Tirone, Federico; Salzano, Stefano; Pagano, Marco

    2018-03-07

    Healing of extraction sockets may sometimes result in formation of fibrous tissue instead of bone, even after 4 months, an occurrence that may hinder implant placement. The aim of this preliminary observational study was to histologically evaluate quality and amount of bone regeneration after treating nonhealing sockets with a bovine-derived xenograft enriched with porcine collagen (Bio-Oss Collagen, Geistlich) without barrier membranes. Biopsy specimens were collected during implant placement, 4 months after grafting. A total of 10 cases were treated and evaluated. In all cases, correct implant placement was possible and no implant failure occurred up to 6 months after loading. The histologic analysis demonstrated new bone formation in all specimens. The percentage of newly formed bone was 29.1% (SD 20.71%; range 5% to 48%). Xenograft particles in direct contact with newly formed bone were visible, and mature lamellar bone was observed in 8 cases.

  9. Identification of Bodies by Unique Serial Numbers on Implanted Medical Devices.

    PubMed

    Blessing, Melissa M; Lin, Peter T

    2018-05-01

    Visual identification is the most common identification method used by medical examiners but is not always possible. Alternative methods include X-ray, fingerprint, or DNA comparison, but these methods require additional resources. Comparison of serial numbers on implanted medical devices is a rapid and definitive method of identification. To assess the practicality of using this method, we reviewed 608 consecutive forensic autopsies performed at a regional medical examiner office. Of these, 56 cases required an alternative method of identification due to decomposition (n = 35), gunshot wound (n = 9), blunt trauma (n = 6), or charring (n = 6). Of these 56 cases, eight (14.3%) were known to have an implanted medical device. Of these eight cases, five (63%) could be positively identified by comparing serial numbers. If an implanted medical device is known to be present, and medical records are available, identification by medical device serial number should be a first-line method. © 2017 American Academy of Forensic Sciences.

  10. Cangrelor use prior to left ventricular assist device surgery: a case series.

    PubMed

    Washam, Jeffrey B; Yerokun, Babatunde; Patel, Chetan B; Welsby, Ian J; Milano, Carmelo A; DeVore, Adam D

    2018-06-02

    Bleeding frequently occurs in patients undergoing placement of a left ventricular assist device (LVAD). Clinical factors that have been identified as contributing to peri-procedural bleeding include LVAD implantation after an acute myocardial infarction and preoperative use of antiplatelet agents. In this report, we describe the use of cangrelor for preoperative antiplatelet bridging to LVAD in five post myocardial infarction patients with cardiogenic shock that had recently undergone percutaneous coronary intervention. During the cangrelor bridging period, no cases of thrombotic or major bleeding events occurred. During the first week following LVAD implantation, two patients experienced a major bleeding (each case required chest exploration for suspected hemorrhage). To our knowledge, this is the first series describing cangrelor use for antiplatelet bridging in patients undergoing LVAD implantation. While this series suggest cangrelor could possibly be a safe and effective antiplatelet bridging strategy, further research is needed to identify the optimal antithrombotic strategy in cardiogenic shock patients undergoing LVAD implantation who have recently undergoing percutaneous coronary intervention.

  11. [Application of serratus anterior muscle flap combined with breast implants for breast reconstruction after modified radical mastectomy].

    PubMed

    Chai, Lijun; Zhang, Xuehui

    2017-09-01

    To investigate effectiveness of the combination of serratus anterior muscle flap and breast implants for breast reconstruction after modified radical mastectomy. Between January 2015 and December 2015, 25 female patients with breast cancer were enrolled, aged 24-62 years (mean, 40.6 years). The tumor located at left side in 9 cases and right side in 16 cases; 14 cases were in the left upper quadrant, 4 cases were in the left lower quadrant, 7 cases were on the top of the breast. All cases were invasive ductal carcinoma. According to TNM staging, 14 cases were at stageⅠand 11 cases were at stageⅡA. The diameter of lumps were all less than 3 cm. All those lumps were solitary and without distant metastasis. The sentinel nodes were all negative. After modified radical mastectomy, the breasts were reconstructed by serratus anterior muscle flap and breast implants. The nipples were spared in 22 cases. The operation time was 113-148 minutes (mean, 136 minutes). All breasts survived and incisions healed at stageⅠ. There was no complication such as hematoma, infection, etc . All patients were followed up 6-18 months (mean, 15 months). Except 1 case, the others were evaluated according to the criteria of the reconstructed breast at 12 months after operation. Among them, 23 cases were evaluated as good and 1 case as fair. There was no tumor recurrence during the follow-up period. The combination of serratus anterior muscle flap and breast implants after the modified radical mastectomy is a handy approach of breast reconstruction which is less harmful with few postoperative complications. It also gains a high degree of satisfaction from patients for good breast shape.

  12. Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 2).

    PubMed

    Piazza, Nicolo; Bleiziffer, Sabine; Brockmann, Gernot; Hendrick, Ruge; Deutsch, Marcus-André; Opitz, Anke; Mazzitelli, Domenico; Tassani-Prell, Peter; Schreiber, Christian; Lange, Rüdiger

    2011-07-01

    This study sought to review the acute procedural outcomes of patients who underwent transcatheter aortic valve (TAV)-in-surgical aortic valve (SAV) implantation at the German Heart Center, Munich, and to summarize the existing literature on TAV-in-SAV implantation (n = 47). There are several case reports and small case series describing transcatheter aortic valve implantation for a failing surgical aortic valve bioprosthesis (TAV-in-SAV implantation). From January 2007 to March 2011, 20 out of 556 patients underwent a TAV-in-SAV implantation at the German Heart Center Munich. Baseline characteristics and clinical outcome data were prospectively entered into a dedicated database. The mean patient age was 75 ± 13 years, and the mean logistic European System for Cardiac Operative Risk Evaluation and Society of Thoracic Surgeons' Risk Model scores were 27 ± 13% and 7 ± 4%, respectively. Of the 20 patients, 14 had stented and 6 had stentless surgical bioprostheses. Most cases (12 of 20) were performed via the transapical route using a 23-mm Edwards Sapien prosthesis (Edwards Lifesciences, Irvine, California). Successful implantation of a TAV in a SAV with the patient leaving the catheterization laboratory alive was achieved in 18 of 20 patients. The mean transaortic valve gradient was 20.0 ± 7.5 mm Hg. None-to-trivial, mild, and mild-to-moderate paravalvular aortic regurgitation was observed in 10, 6, and 2 patients, respectively. We experienced 1 intraprocedural death following pre-implant balloon aortic valvuloplasty ("stone heart") and 2 further in-hospital deaths due to myocardial infarction. TAV-in-SAV implantation is a safe and feasible treatment for high-risk patients with failing aortic bioprosthetic valves and should be considered as part of the armamentarium in the treatment of aortic bioprosthetic valve failure. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Bits and Pieces: A Crowd-Sourced Series of 54 Cases of Fractured Hormonal Implants.

    PubMed

    Crouthamel, Bonnie C; Schiff, Melissa A; Amies Oelschlager, Anne-Marie E; Prager, Sarah W; Debiec, Katherine E

    2018-04-01

    The fracture of hormonal implants, including Implanon, Nexplanon (both from Merck & Co, Inc), and histrelin acetate is rare. Our aim was to describe patient demographic characteristics, mechanisms, and consequences of fractured implants by surveying physicians' experience via listservs and social media. DESIGN, SETTING, PARTICIPANTS, INTERVENTIONS, AND MAIN OUTCOME MEASURES: We developed a Research Electronic Data Capture survey for physicians regarding their experience with implant fracture, including patient characteristics, mechanism of fracture, changes in menstrual bleeding patterns, time from insertion to fracture, and time from fracture to seeking care. We distributed the survey to providers in listservs for the North American Society for Pediatric and Adolescent Gynecology, the Family Planning Fellowship, the Ryan Program, and the Facebook Physician Moms Group and Facebook OB-GYN Mom Group. We performed descriptive analyses. We received 42 survey responses, representing 54 discrete implant fractures of which 70% (n=14) were Nexplanon, 26% (n=38) were Implanon, and 4% (n=2) were histrelin acetate. Mechanisms of implant fracture included patient manipulation (23%, n=12), unintentional trauma (11%, n=6), interpersonal violence (8%, n=4), lifting/carrying (6%, n=3), fracture with removal (6%, n=3), and unknown (47%, n=25). Bleeding pattern was not altered in 78% (n=42) of cases. Time interval between placement and fracture was less than 2 years for 63% (n=34) of cases. Thirty-nine percent (n=21) of patients presented for care more than 1 month from the time of fracture. Patients should be counseled about potential for hormonal implant fracture, advised against excessive manipulation of implants, and counseled to present for care immediately upon noticing an implant fracture. Surveying physicians through listervs and social media is an effective strategy to increase the reporting of rare complications and events. Copyright © 2017 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  14. Developmental dysgraphia with profound hearing impairment: intervention by auditory methods enabled by cochlear implant.

    PubMed

    Fukushima, Kunihiro; Kawasaki, Akihiro; Nagayasu, Rie; Kunisue, Kazuya; Maeda, Yukihide; Kariya, Shin; Kataoka, Yuko; Nishizaki, Kazunori

    2008-06-01

    Learning disability combined with hearing impairment (LDHI) is a poor prognostic factor for the language development of hearing impaired children after educational intervention. A typical example of a child with LDHI and effective interventions provided by cochlear implants are presented in this report. A case of congenital cytomegaloviral infection that showed dysgraphia as well as profound deafness was reported and an underlying visual processing problem diagnosed in the present case caused the patient's dysgraphia. The dysgraphia could be circumvented by the use of auditory memory fairly established by a cochlear implant.

  15. Transdisciplinary treatment of Class III malocclusion using conventional implant-supported anchorage: 10-year posttreatment follow-up

    PubMed Central

    Rinaldi, Mariana Roennau Lemos; Rizzatto, Susana Maria Deon; de Menezes, Luciane Macedo; Polido, Waldemar Daudt; de Lima, Eduardo Martinelli Santayanna

    2015-01-01

    INTRODUCTION: Combined treatment offers advantages for partially edentulous patients. Conventional implants, used as orthodontic anchorage, enable previous orthodontic movement, which provides appropriate space gain for crown insertion. OBJECTIVE: This case report describes the treatment of a 61-year and 10-month-old patient with negative overjet which made ideal prosthetic rehabilitation impossible, thereby hindering dental and facial esthetics. CASE REPORT: After a diagnostic setup, conventional implants were placed in the upper arch to anchor intrusion and retract anterior teeth. Space gain for lateral incisors was achieved in the lower arch by means of an orthodontic appliance. CONCLUSIONS: Integrated planning combining Orthodontics and Implantology provided successful treatment by means of conventional implant-supported anchorage. The resulting occlusal relationship proved stable after 10 years. PMID:26154459

  16. Cumulative costs for the prosthetic reconstructions and maintenance in young adult patients with birth defects affecting the formation of teeth.

    PubMed

    Incici, Erol; Matuliene, Giedre; Hüsler, Jürg; Salvi, Giovanni E; Pjetursson, Bjarni; Brägger, Urs

    2009-07-01

    To assess retrospectively the cumulative costs for the long-term oral rehabilitation of patients with birth defects affecting the development of teeth. Patients with birth defects who had received fixed reconstructions on teeth and/or implants > or =5 years ago were asked to participate in a comprehensive clinical, radiographic and economic evaluation. From the 45 patients included, 18 were cases with a cleft lip and palate, five had amelogenesis/dentinogenesis imperfecta and 22 were cases with hypodontia/oligodontia. The initial costs for the first oral rehabilitation (before the age of 20) had been covered by the Swiss Insurance for Disability. The costs for the initial rehabilitation of the 45 cases amounted to 407,584 CHF (39% for laboratory fees). Linear regression analyses for the initial treatment costs per replaced tooth revealed the formula 731 CHF+(811 CHF x units) on teeth and 3369 CHF+(1183 CHF x units) for reconstructions on implants (P<.001). Fifty-eight percent of the patients with tooth-supported reconstructions remained free from failures/complications (median observation 15.7 years). Forty-seven percent of the patients with implant-supported reconstructions remained free from failures/complications (median observation 8 years). The long-term cumulative treatment costs for implant cases, however, were not statistically significantly different compared with cases reconstructed with tooth-supported fixed reconstructions. Twenty-seven percent of the initial treatment costs were needed to cover supportive periodontal therapy as well as the treatment of technical/biological complications and failures. Insurance companies should accept to cover implant-supported reconstructions because there is no need to prepare healthy teeth, fewer tooth units need to be replaced and the cumulative long-term costs seem to be similar compared with cases restored on teeth.

  17. Transapical Mitral Valve Implantation for Native Mitral Valve Stenosis Using a Balloon-Expandable Prosthesis.

    PubMed

    Kiefer, Philipp; Noack, Thilo; Seeburger, Joerg; Hoyer, Alexandro; Linke, Axel; Mangner, Norman; Lehmkuhl, Lukas; Mohr, Friedrich Wilhelm; Holzhey, David

    2017-12-01

    Transcatheter mitral valve implantation (TMVI) is still in its infancy and is mainly limited to valve-in-valve or valve-in-ring implantations. We present the early experience with TMVI for severe calcified native MV stenosis. Between January 2014 and June 2015, 6 of 11 patients screened (mean age, 77.4 ± 6.3 years; 66% men) with severe native mitral valve (MV) stenosis (mean gradient [Pmean], 11.1 ± 2.1 mm Hg; mean effective orifice area [EOA], 0.9 ± 0.12 cm 2 ) underwent transcatheter MV replacement at our institution as a bailout procedure. Conventional surgical procedures were denied in all patients because of severe annular calcification and extensive comorbidities (mean logistic EuroScore, 31.4% ± 8.3%). The Edwards SAPIEN 3 (29 mm) (Edwards Lifesciences, Irvine, CA) was used in all cases. Procedural access was transapical in 5 cases and concomitant to aortic valve replacement through the left atrium through a sternotomy in 1 case. Initial implantation was successful in 100% of the cases. Because of early migration, 1 patient needed a valve-in-valve procedure. Postoperative echocardiography showed no residual mitral regurgitation in 4 cases (66%) and mild regurgitation in 2 cases (34%). Mean gradients were reduced to 4.2 ± 0.6 mm Hg (mean EOA, 2.8 ± 0.4 cm 2) . No patient had a stroke during hospitalization, and 30-day mortality was seen in 1 patient (17%) resulting from pneumonia. TMV implantation using the SAPIEN 3 aortic prosthesis in patients with heavy annular calcification is feasible and represents a reasonable bailout option for inoperable patients. However, several limitations need to be considered in this special patient population. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Use of a very flexible guide wire to permit dilation of complex malignant strictures of the esophagus.

    PubMed

    Vargas-Tank, L; Ovalle, L; Fernández, C; Mella, B; Estay, R; del Solar, M P; Soto, J R

    1995-01-01

    Risk of perforation is a major impediment to the use of polyvinyl bougies in palliative dilation of cancerous strictures of the esophagus. We encountered 23 patients with complex malignant strictures in whom initial dilation with Savary-Gilliard bougies was thwarted because attempts to pass a conventional Eder-Puestow guide wire were unsuccessful. As a recourse, we probed these strictures with a very flexible guide wire of the type used to implant prostheses in the biliary tract. The purpose was to establish a passage through which a standard guide wire could then be inserted. The procedure was successful in all but 4 of the 23 patients. We conclude that in such cases the preliminary use of the very flexible guide, even though time-consuming, improves the chance of effective dilation with minimal added risk.

  19. [Clinical evaluation of the ceramic femoral component used for reconstruction of total knee replacement].

    PubMed

    Vavrík, P; Landor, I; Denk, F

    2008-12-01

    The study evaluates mid-term results of total knee replacement with a zirconia ceramic (ZrO2) femoral component. The evaluated group comprised 20 knees in 19 patients (4 men and 15 women). In one patient the replacement was performed bilaterally. Two patients had in the contralateral knee the same type of prosthesis with a femoral chrome-cobalt component.The mean age at the time of operation was 65.2 years (range, 38-81 years).The primary indication was 14 times osteoarthritis and 5 times rheumatoid arthritis. The average follow-up period was 6.5 years (range, 2.1-8.5 years). Patients included in the study regardless of age, body mass and the basic diagnosis, agreed with the use of the ceramic femoral component. The evaluation covered a range of motion, mechanical axis, joint stability, pain, swelling, ability to walk on level ground and on stairs, subjective satisfaction (EULAR Knee Chart). Radiograph were assessed at one year intervals in two projections to identify the incidence of radiolucency around the implant. The Kaplan-Meier survival curve was used and compared with the survival curve in identical chrome-cobalt implants. At he final follow-up, 14 knees were evaluated, because 3 patients died without any connection with the implant, in one case the tibial component migrated due to necrosis of the tibial condyle in a patient with RA and two implants had to be revised and replaced due to polyethylene wear. No infection or negative tissue reaction was recorded in the evaluated group. The average flexion range was 109 degrees. All knees were stable and without swelling, in two cases there occurred slight femoropatellar pain. Twelve patients were fully satisfied, 2 patients were satisfied with a certain reservation. The differences in the course of the survival curves of chrome-cobalt and ceramic implants were statistically insignificant. Although the use of zirconia ceramics in vitro reduces the amount of polyethylene wear, the clinical outcomes of total knee replacements as compared to the hip are not convincing. One of the causes may be the substantially different and more complex biomechanics of the knee. Tribology improvement of the femoral ceramic component cannot compensate the deficiencies in the joint balancing in flexion and extension. The economically and technologically demanding production of these implants may be justified in patients with allergies caused by chrome-cobalt components. The results of mid-term follow-up of the use of zirconia ceramic femoral components proved no impact on the improvement of the period of survival of the knee implant. No adverse response to the material or mechanical failure of the ceramic components was encountered. Key words: total knee replacement, zirconia ceramic femoral component, TKR mid-term results, ceramic knee survival curve.

  20. A method for visualizing high-density porous polyethylene (medpor, porex) with computed tomographic scanning.

    PubMed

    Vendemia, Nicholas; Chao, Jerry; Ivanidze, Jana; Sanelli, Pina; Spinelli, Henry M

    2011-01-01

    Medpor (Porex Surgical, Inc, Newnan, GA) is composed of porous polyethylene and is commonly used in craniofacial reconstruction. When complications such as seroma or abscess formation arise, diagnostic modalities are limited because Medpor is radiolucent on conventional radiologic studies. This poses a problem in situations where imaging is necessary to distinguish the implant from surrounding tissues. To present a clinically useful method for imaging Medpor with conventional computed tomographic (CT) scanning. Eleven patients (12 total implants) who have undergone reconstructive surgery with Medpor were included in the study. A retrospective review of CT scans done between 1 and 16 months postoperatively was performed using 3 distinct CT window settings. Measurements of implant dimensions and Hounsfield units were recorded and qualitatively assessed. Of the 3 distinct window settings studied, namely, "bone" (W1100/L450), "soft tissue"; (W500/L50), and "implant" (W800/L200), the implant window proved the most ideal, allowing the investigators to visualize and evaluate Medpor in all cases. Qualitative analysis revealed that Medpor implants were able to be distinguished from surrounding tissue in both the implant and soft tissue windows, with a density falling between that of fat and fluid. In 1 case, Medpor could not be visualized in the soft tissue window, although it could be visualized in the implant window. Quantitative analysis demonstrated a mean (SD) density of -38.7 (7.4) Hounsfield units. Medpor may be optimally visualized on conventional CT scans using the implant window settings W800/L200, which can aid in imaging Medpor and diagnosing implant-related complications.

Top