Sample records for complex zmc fractures

  1. [Diagnosis and management of zygomaticomaxillary complex fractures].

    PubMed

    Xu, Bing; Zheng, Jia-wei; Shi, Jun

    2006-12-01

    The zygornaticomaxillarx complex (ZMC) plays an important role in maintaining the structure and function of the face. The prominent convex shape of the ZMC makes it particularly vulnerable to trauma, resulting in a tetrapod fracture involving all four buttresses. ZMC fracture usually leads to local depressed deformities, even dysfunction such as limited mouth opening and diplopia. This article lescribes the etiology, clinical features, surgical approaches and postoperative complications of ZMC fractures based on our own clinical experiences and literature review. It is believed that lateral brow incision combined with intraoral incision can provide better access to ZMC fractures and avoid the disadvantages caused by coronal incision. This surgical approach leaves minimal scar and injury to the facial nerve, with better esthetic and functional outcomes. Supported by Shanghai Leading Academic Discipline Project (Grant No. Y0203).

  2. Use of Intraoperative Computed Tomography for Revisional Procedures in Patients with Complex Maxillofacial Trauma

    PubMed Central

    Singh, Mansher; Ricci, Joseph A.

    2015-01-01

    Background: In patients with panfacial fractures and distorted anatomic landmarks of zygomatic and orbital complex, there is a risk of zygomaticomaxillary complex (ZMC) malpositioning even with the best efforts for surgical repair. This results in increased number of additional procedures to achieve accurate positioning. Methods: We describe the usage of intraoperative C-arm cone-beam computed tomographic (CT) scan for ZMC malpositioning in a representative patient with panfacial fractures. Results: We have successfully used intraoperative CT scan for ZMC malpositioning in 3 patients. The representative patient had ZMC malposition after the initial attempt of surgical repair without any intraoperative imaging. On using intraoperative CT scan during the next attempt, we were able to reposition the ZMC accurately. Conclusions: Intraoperative CT scan might improve the accuracy of ZMC positioning and decrease the chances of potential additional surgeries. In patients with distorted anatomical landmarks and panfacial fractures, it can be especially helpful toward correcting ZMC malposition. PMID:26301152

  3. Status of the internal orbit after reduction of zygomaticomaxillary complex fractures.

    PubMed

    Ellis, Edward; Reddy, Likith

    2004-03-01

    We sought to determine the status of the internal orbit before and after reduction of zygomaticomaxillary complex (ZMC) fractures when treated without internal orbital reconstruction. We conducted a retrospective study of preoperative and postoperative computed tomography (CT) scans in 65 patients with unilateral ZMC fractures who were treated by reduction of the ZMC complex without internal orbital reconstruction. The size and location of the internal orbital defects, orbital soft tissue displacement, and orbital volume were assessed in the preoperative and postoperative CT scans. Reduction in the ZMC fractures was considered ideal in 58 of the 65 patients. Only minor malpositions occurred in the remaining 7 patients. The size of the internal orbital defects increased slightly with ZMC reduction but the internal orbital fractures were realigned, and few had increases in orbital volume or soft tissue sagging into the sinuses. Examination of follow-up CT scans in several patients taken weeks to months later showed that the residual defects became smaller and that none of these patients had an increase in orbital volume or soft tissue sagging. The preoperative CT scan can be used to assess the amount of internal orbital disruption for purposes of developing a treatment plan in patients with ZMC fractures. When there is minimal or no soft tissue herniation and minimal disruption of the internal orbit, ZMC reduction is adequate treatment.

  4. Electromyography assessment in zygomaticomaxillary complex fractures.

    PubMed

    Waheed El-Anwar, Mohammad; Elsheikh, Ezzeddin; Sweed, Ahmed Hassan; Ezzeldin, Nillie

    2015-12-01

    The aim of this study was to assess the activity of the masseter and temporalis muscles using surface electromyography (EMG) in patients with zygomaticomaxillary complex (ZMC) fractures. This prospective study was carried out on 25 patients who had ZMC fractures. Fifteen patients were managed by open reduction and rigid fixation (ORIF) using titanium miniplates. This study, using surface electromyography, analyzed the activity of the masseter and temporalis muscles of 25 patients with ZMC fractures; 15 of them were surgically treated under general anesthesia (GA). Evaluations were made before surgery and 6 weeks after surgery by recording the mean of muscle contraction of 20 motor unit action potential (MUAP) against resistance, and statistical analyses were performed. A significant EMG difference between the normal and ZMC fracture sides was found (P < 0.0001) for both masseter and temporalis muscles and was significantly improved after ORIF. However, postoperative EMV values of the repaired side was significantly less than measured postoperatively in the normal side (P < 0.0001) for both muscles. ZMC fractures significantly diminish muscular activity of the masseter and temporalis and even though significant recovery of muscle activity was revealed after 6 weeks, it is still less than normal activity, highlighting the importance of postoperative rehabilitation.

  5. Effect of air bags and restraining devices on the pattern of facial fractures in motor vehicle crashes.

    PubMed

    Simoni, Payman; Ostendorf, Robert; Cox, Artemus J

    2003-01-01

    To examine the relationship between the use of restraining devices and the incidence of specific facial fractures in motor vehicle crashes. Retrospective analysis of patients with facial fractures following a motor vehicle crash. University of Alabama at Birmingham Hospital level I trauma center from 1996 to 2000. Of 3731 patients involved in motor vehicle crashes, a total of 497 patients were found to have facial fractures as determined by International Classification of Diseases, Ninth Revision (ICD-9) codes. Facial fractures were categorized as mandibular, orbital, zygomaticomaxillary complex (ZMC), and nasal. Use of seat belts alone was more effective in decreasing the chance of facial fractures in this population (from 17% to 8%) compared with the use of air bags alone (17% to 11%). The use of seat belts and air bags together decreased the incidence of facial fractures from 17% to 5%. Use of restraining devices in vehicles significantly reduces the chance of incurring facial fractures in a severe motor vehicle crash. However, use of air bags and seat belts does not change the pattern of facial fractures greatly except for ZMC fractures. Air bags are least effective in preventing ZMC fractures. Improving the mechanics of restraining devices might be needed to minimize facial fractures.

  6. Anatomical Thin Titanium Mesh Plate Structural Optimization for Zygomatic-Maxillary Complex Fracture under Fatigue Testing.

    PubMed

    Wang, Yu-Tzu; Huang, Shao-Fu; Fang, Yu-Ting; Huang, Shou-Chieh; Cheng, Hwei-Fang; Chen, Chih-Hao; Wang, Po-Fang; Lin, Chun-Li

    2018-01-01

    This study performs a structural optimization of anatomical thin titanium mesh (ATTM) plate and optimal designed ATTM plate fabricated using additive manufacturing (AM) to verify its stabilization under fatigue testing. Finite element (FE) analysis was used to simulate the structural bending resistance of a regular ATTM plate. The Taguchi method was employed to identify the significance of each design factor in controlling the deflection and determine an optimal combination of designed factors. The optimal designed ATTM plate with patient-matched facial contour was fabricated using AM and applied to a ZMC comminuted fracture to evaluate the resting maxillary micromotion/strain under fatigue testing. The Taguchi analysis found that the ATTM plate required a designed internal hole distance to be 0.9 mm, internal hole diameter to be 1 mm, plate thickness to be 0.8 mm, and plate height to be 10 mm. The designed plate thickness factor primarily dominated the bending resistance up to 78% importance. The averaged micromotion (displacement) and strain of the maxillary bone showed that ZMC fracture fixation using the miniplate was significantly higher than those using the AM optimal designed ATTM plate. This study concluded that the optimal designed ATTM plate with enough strength to resist the bending effect can be obtained by combining FE and Taguchi analyses. The optimal designed ATTM plate with patient-matched facial contour fabricated using AM provides superior stabilization for ZMC comminuted fractured bone segments.

  7. Transconjunctival versus subciliary approach to the infraorbital margin for open reduction of zygomaticomaxillary complex fractures: a randomized feasibility study.

    PubMed

    El-Anwar, Mohammad Waheed; Elsheikh, Ezzeddin; Hussein, Atef M; Tantawy, Adly A; Abdelbaki, Youssef Mansour

    2017-06-01

    Although some studies addressed the differences between subciliary and transconjunctival approaches, no previous prospective comparative study on displaced zygomaticomaxillary complex (ZMC) fracture that repaired by three-point internal fixation using also upper gingivolabial incision and upper eye lid incision. So, the effect of these incisions on the comparison was not investigated. The purpose of this study was to compare transconjunctival and subciliary approaches for open reduction and internal rigid fixation (OR/IF) of ZMC fractures. This prospective study was carried out on 40 patients had displaced ZMC fractures repaired by OR/IF. Patients were randomly assigned into two equal groups (20 patients for each); subciliary group subjected to subciliary approach and transconjunctival group subjected to transconjunctival approach for inferior orbital rim repair. In both groups, frontozygomatic and zygomaticomaxillary buttresses were also approached by lateral eye brow and superior gingivolabial incision, respectively. Primary outcome measures include accessibility (need for lateral canthotomy), the exposure duration, postoperative pain, early postoperative edema, and operative complications. Secondary outcome measures include dental occlusion, average intrinsic vertical mouth opening, post subciliary scar assessment, late postoperative complication, and opthalmological assessment concerning ectropion, entropion, scleral show, and eye globe affection (enophthalmos or diplopia). The mean duration from incisions to fracture exposure was 13.7 ± 2.17 min in subciliary approach and 14.6 ± 2.31 min in transconjunctival approach with nonsignificant difference (p = 0.1284). Lateral canthotomy was required for proper exposure of the fracture and OR/IF using transconjunctival approach while not needed with subciliary approach. Ectropion and scleral show occurred in 10 and 15% respectively in subciliary group and were not encountered in transconjunctival group. Although postoperative periorbital edema was significantly more sever in transconjunctival group within the first postoperative week (p = 0.028), no persistent periorbital edema was reported. Infection, hematoma, and globe complication were not detected in any patient. All authors characterized all scars of the subciliary group as unnoticeable. Transconjunctival approach mostly needs lateral canthotomy that was not needed with subciliary approach. Transient postoperative edema is more in transconjunctival approach while postoperative ectropion and sclera show was detected only with subciliary approach. So, building up of experience in transconjunctival approach will be beneficial for maxillofacial surgeons and more measures to avoid ectropion are needed with subciliary approach.

  8. Broccoli-like porous carbon nitride from ZIF-8 and melamine for high performance supercapacitors

    NASA Astrophysics Data System (ADS)

    Cai, Chenglong; Zou, Yongjin; Xiang, Cuili; Chu, Hailiang; Qiu, Shujun; Sui, Qingli; Xu, Fen; Sun, Lixian; Shah, Afzal

    2018-05-01

    Broccoli-like porous carbon nitride is synthesized by simple one-step carbonization of a composite comprising a Zn-based zeolitic imidazolate framework (ZIF-8) and melamine. The introduction of melamine into the ZIF-8 framework not only increases the N content of the composite and the surface area of the carbonization product, but also induces the formation of a flower-like structure. The carbon obtained from the ZIF-8/melamine composite by the proposed carbonization process at a temperature of 800 °C (ZM-C-800) is found to have a unique three-dimensional broccoli-like shape, a nanoscale size, and an extremely high doping N content (28.3 at.%). These properties substantially improve the electrochemical performance of ZM-C-800, as represented by a high specific capacitance of 359.1 F g-1 at a current density of 1 A g-1, much higher than that of ZIF-8. Furthermore, a symmetric supercapacitor fabricated with two ZM-C-800 electrodes exhibits a power density of 498.5 W kg-1 for an energy density of 11.4 Wh kg-1. This indicates the strong potential of ZM-C-800 for use in the fabrication of energy storage devices.

  9. A comprehensive study on maxillofacial trauma conducted in Yamunanagar, India

    PubMed Central

    Bali, Rishi; Sharma, Parveen; Garg, Amandeep; Dhillon, Guneet

    2013-01-01

    Abstract: Background: The Department of Oral and Maxillofacial Surgery, D.A.V [C] Dental College and Hospital, Yamuna Nagar, Haryana, India conducted a study on patients with maxillofacial fractures in a time span of seven years (2003-2010). The purpose of this study was to evaluate their aetiology, incidence, patterns and different modalities employed for management. Methods: In this study, 740 patients with 1054 fractures were evaluated clinically and radiographically, based on which closed reduction and open reduction was undertaken. Review of patient records included: Age, sex, time, mechanism and etiology of injury, history of bleeding, unconsciousness and prior first aid, type of vehicle and use of preventive measures, type of fracture and treatment modalities. Results: Road traffic accidents accounted for highest number of fractures predominantly occurring in the age group of 21-30 years (38.3%)1,2. Males incurred more fractures with a male female ratio of 4.2: 1.Mandible was the most commonly fractured bone with parasymphysis being the commonest affected site.76.66% patients had associated head injury and 15.68 % had history of unconsciousness. Open reduction and internal fixation was the preferred modality for mandible whereas the mid face fractures were treated more often by closed methods. Conclusions: Injuries occurred more commonly in 20 – 40 age range with road traffic accident being the major etiological factor. Majority of the patients were driving two wheelers and most were under the effect of alcohol. Most of the injuries occurred during night and road traffic accidents (71.89%) were found to be the major etiological factor. Out of 532 road traffic accidents, 490 patients (66.2%) were on two wheelers, among whom 49(10%) were wearing helmet. In the mandible, fractures occurred most commonly in the parasymphyseal region (224, 30.2%), and out of the 314 fractures of the middle third showed, 155 (49.4%) ZMC. OPG was the most commonly advised X-ray. With regard to treatment modalities, 36.8% of all the mandibular fractures (740) were treated by closed reduction, 62.6% were treated using open reduction and 0.5% was under observation only. PMID:23594725

  10. 77 FR 60722 - Certain Coenzyme Q10 Products and Methods of Making Same; Notice of Request for Statements on the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-04

    ... respondents Zhejiang Medicine Co., Ltd., ZMC-USA, L.L.C., Xiamen Kingdomway Group Company, Pacific Rainbow... and Technology Co., Ltd. FOR FURTHER INFORMATION CONTACT: Lisa R. Barton, Acting Secretary to the...

  11. The role of ZmWRKY4 in regulating maize antioxidant defense under cadmium stress.

    PubMed

    Hong, Changyong; Cheng, Dan; Zhang, Guoqiang; Zhu, Dandan; Chen, Yahua; Tan, Mingpu

    2017-01-22

    WRKY transcription factors act as positive regulators in abiotic stress responses by activation of the cellular antioxidant systems. However, there are few reports on the response of WRKY genes to cadmium (Cd) stress. In this study, the role of maize ZmWRKY4 in regulating antioxidant enzymes in Cd stress was investigated. The results indicated that Cd induced up-regulation of the expression and the activities of ZmWRKY4 and superoxide dismutase (SOD) and ascorbate peroxidase (APX). Transient expression and RNA interference (RNAi) silencing of ZmWRKY4 in maize mesophyll protoplasts further revealed that ZmWRKY4 was required for the abscisic acid (ABA)-induced increase in expression and activity of SOD and APX. Overexpression of ZmWRKY4 in protoplasts upregulated the expression and the activities of antioxidant enzymes, whereas ABA induced increases in the expression and the activities of antioxidant enzymes were blocked by the RNAi silencing of ZmWRKY4. Bioinformatic analysis indicated that ZmSOD4 and ZmcAPX both harbored two W-boxes, binding motif for WRKY transcription factors, in their promoter region. Intriguingly, ZmWRKY4 belongs to group I WRKYs with two WRKY domains. Moreover, the synchronized expression patterns indicate that ZmWRKY4 might play a critical role in either regulating the ZmSOD4 and ZmcAPX expression or cooperating with them in response to stress and phytohormone. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. The drag characteristics of several airships determined by deceleration tests

    NASA Technical Reports Server (NTRS)

    Thompson, F L; Kirschbaum, H W

    1932-01-01

    This report presents the results of deceleration tests conducted for the purpose of determining the drag characteristics of six airships. The tests were made with airships of various shapes and sizes belonging to the Army, the Navy, and the Goodyear-Zeppelin Corporation. Drag coefficients for the following airships are shown: Army TC-6, TC-10, and TE-2; Navy Los Angeles and ZMC-2; Goodyear Puritan. The coefficients vary from about 0.045 for the small blunt airships to 0.023 for the relatively large slender Los Angeles. This variation may be due to a combination of effects, but the most important of these is probably the effect of length-diameter ratio.

  13. A Comprehensive Model for Real Gas Transport in Shale Formations with Complex Non-planar Fracture Networks

    PubMed Central

    Yang, Ruiyue; Huang, Zhongwei; Yu, Wei; Li, Gensheng; Ren, Wenxi; Zuo, Lihua; Tan, Xiaosi; Sepehrnoori, Kamy; Tian, Shouceng; Sheng, Mao

    2016-01-01

    A complex fracture network is generally generated during the hydraulic fracturing treatment in shale gas reservoirs. Numerous efforts have been made to model the flow behavior of such fracture networks. However, it is still challenging to predict the impacts of various gas transport mechanisms on well performance with arbitrary fracture geometry in a computationally efficient manner. We develop a robust and comprehensive model for real gas transport in shales with complex non-planar fracture network. Contributions of gas transport mechanisms and fracture complexity to well productivity and rate transient behavior are systematically analyzed. The major findings are: simple planar fracture can overestimate gas production than non-planar fracture due to less fracture interference. A “hump” that occurs in the transition period and formation linear flow with a slope less than 1/2 can infer the appearance of natural fractures. The sharpness of the “hump” can indicate the complexity and irregularity of the fracture networks. Gas flow mechanisms can extend the transition flow period. The gas desorption could make the “hump” more profound. The Knudsen diffusion and slippage effect play a dominant role in the later production time. Maximizing the fracture complexity through generating large connected networks is an effective way to increase shale gas production. PMID:27819349

  14. A Comprehensive Model for Real Gas Transport in Shale Formations with Complex Non-planar Fracture Networks.

    PubMed

    Yang, Ruiyue; Huang, Zhongwei; Yu, Wei; Li, Gensheng; Ren, Wenxi; Zuo, Lihua; Tan, Xiaosi; Sepehrnoori, Kamy; Tian, Shouceng; Sheng, Mao

    2016-11-07

    A complex fracture network is generally generated during the hydraulic fracturing treatment in shale gas reservoirs. Numerous efforts have been made to model the flow behavior of such fracture networks. However, it is still challenging to predict the impacts of various gas transport mechanisms on well performance with arbitrary fracture geometry in a computationally efficient manner. We develop a robust and comprehensive model for real gas transport in shales with complex non-planar fracture network. Contributions of gas transport mechanisms and fracture complexity to well productivity and rate transient behavior are systematically analyzed. The major findings are: simple planar fracture can overestimate gas production than non-planar fracture due to less fracture interference. A "hump" that occurs in the transition period and formation linear flow with a slope less than 1/2 can infer the appearance of natural fractures. The sharpness of the "hump" can indicate the complexity and irregularity of the fracture networks. Gas flow mechanisms can extend the transition flow period. The gas desorption could make the "hump" more profound. The Knudsen diffusion and slippage effect play a dominant role in the later production time. Maximizing the fracture complexity through generating large connected networks is an effective way to increase shale gas production.

  15. The Shear Mechanisms of Natural Fractures during the Hydraulic Stimulation of Shale Gas Reservoirs.

    PubMed

    Zhang, Zhaobin; Li, Xiao

    2016-08-23

    The shearing of natural fractures is important in the permeability enhancement of shale gas reservoirs during hydraulic fracturing treatment. In this work, the shearing mechanisms of natural fractures are analyzed using a newly proposed numerical model based on the displacement discontinuities method. The fluid-rock coupling system of the model is carefully designed to calculate the shearing of fractures. Both a single fracture and a complex fracture network are used to investigate the shear mechanisms. The investigation based on a single fracture shows that the non-ignorable shearing length of a natural fracture could be formed before the natural fracture is filled by pressurized fluid. Therefore, for the hydraulic fracturing treatment of the naturally fractured shale gas reservoirs, the shear strength of shale is generally more important than the tensile strength. The fluid-rock coupling propagation processes of a complex fracture network are simulated under different crustal stress conditions and the results agree well with those of the single fracture. The propagation processes of complex fracture network show that a smaller crustal stress difference is unfavorable to the shearing of natural fractures, but is favorable to the formation of complex fracture network.

  16. The Shear Mechanisms of Natural Fractures during the Hydraulic Stimulation of Shale Gas Reservoirs

    PubMed Central

    Zhang, Zhaobin; Li, Xiao

    2016-01-01

    The shearing of natural fractures is important in the permeability enhancement of shale gas reservoirs during hydraulic fracturing treatment. In this work, the shearing mechanisms of natural fractures are analyzed using a newly proposed numerical model based on the displacement discontinuities method. The fluid-rock coupling system of the model is carefully designed to calculate the shearing of fractures. Both a single fracture and a complex fracture network are used to investigate the shear mechanisms. The investigation based on a single fracture shows that the non-ignorable shearing length of a natural fracture could be formed before the natural fracture is filled by pressurized fluid. Therefore, for the hydraulic fracturing treatment of the naturally fractured shale gas reservoirs, the shear strength of shale is generally more important than the tensile strength. The fluid-rock coupling propagation processes of a complex fracture network are simulated under different crustal stress conditions and the results agree well with those of the single fracture. The propagation processes of complex fracture network show that a smaller crustal stress difference is unfavorable to the shearing of natural fractures, but is favorable to the formation of complex fracture network. PMID:28773834

  17. Rigid fixation of facial fractures in children.

    PubMed

    Koltai, P J; Rabkin, D; Hoehn, J

    1995-01-01

    This article presents a retrospective analysis of a selective use of rigid fixation among 62 children with facial fractures, treated at a Level I trauma center over a 5-year period (1986-1991). There were 21 mandible fractures, 11 orbital fractures, 11 zygomaticomalar complex fractures, 7 nasal fractures, 5 maxillary fractures, 3 pan-facial fractures, 2 nasal-orbital-ethmoidal complex fractures, and 2 frontal sinus fractures. Only 18 children had rigid fixation of their injuries. Complications of Le Fort upper facial fractures repaired with rigid fixation involved perioperative sinusitis; one case required oral antibiotics, the other ethmoidectomy and maxillary antrostomy. One child with a Le Fort fracture had delayed exposure of a zygomaticomalar buttress plate, which required surgical removal. Permanent enophthalmos occurred in two children with Le Fort fractures. The authors conclude that traditional conservative management is appropriate in most cases. However, in children aged 13 and older with mandible fractures and children with complex mid- and upper facial fractures, a judicious use of rigid fixation has advantages over the traditional techniques.

  18. Complex and open fractures: a straightforward approach to management in the cat.

    PubMed

    Corr, Sandra

    2012-01-01

    Cats often present with traumatic injuries of the limbs, including complex and open fractures, frequently as a result of road traffic accidents. On initial assessment, complex and open fractures may appear to require expertise beyond the experience of the general practitioner and, in some cases, referral to a specialist may be indicated or amputation should be considered. Many cases, however, can be managed using straightforward principles. This review describes a logical and practical approach to treating such injuries. It discusses general principles of fracture management, highlights the treatment of open fractures, and describes the use of external skeletal fixation for stabilisation of both open and complex fractures. Most fractures can be stabilised using equipment and expertise available in general practice if the basic principles of fracture fixation are understood and rigorously applied. Many textbooks and journal articles have been published on the management of fractures in companion animals, presenting case studies, case series and original biomechanical research. The simple strategy for managing complex injuries that is provided in this review is based on the published literature and the author's clinical experience.

  19. Storm-time changes of geomagnetic field at MAGSAT altitudes (325-550 Km) and their comparison with changes at ground locations

    NASA Technical Reports Server (NTRS)

    Parada, N. D. J. (Principal Investigator); Kane, R. P.; Trivedi, N. B.

    1983-01-01

    The values of H, X, Y, Z at MAGSAT altitudes were first expressed as residuals delta H, delta X, delta Y, delta Z after subtracting the model HMD, XMD, YMD, ZMC. The storm-time variations of H showed that delta H (Dusk) was larger (negative) than delta H (Dawn) and occurred earlier, indicating a sort of hysteresis effect. Effects at MAGSAT altitudes were roughly the same (10% accuracy) as at ground, indicating that these effects were mostly of magnetospheric origin. The delta Y component also showed large storm-time changes. The latitudinal distribution of storm-time delta H showed north-south asymmetries varying in nature as the storm progressed. It seems that the central plane of the storm-time magnetospheric ring current undergoes latitudinal meanderings during the course of the storm.

  20. Complex Fluids and Hydraulic Fracturing.

    PubMed

    Barbati, Alexander C; Desroches, Jean; Robisson, Agathe; McKinley, Gareth H

    2016-06-07

    Nearly 70 years old, hydraulic fracturing is a core technique for stimulating hydrocarbon production in a majority of oil and gas reservoirs. Complex fluids are implemented in nearly every step of the fracturing process, most significantly to generate and sustain fractures and transport and distribute proppant particles during and following fluid injection. An extremely wide range of complex fluids are used: naturally occurring polysaccharide and synthetic polymer solutions, aqueous physical and chemical gels, organic gels, micellar surfactant solutions, emulsions, and foams. These fluids are loaded over a wide range of concentrations with particles of varying sizes and aspect ratios and are subjected to extreme mechanical and environmental conditions. We describe the settings of hydraulic fracturing (framed by geology), fracturing mechanics and physics, and the critical role that non-Newtonian fluid dynamics and complex fluids play in the hydraulic fracturing process.

  1. The correlation of initial radiographic characteristics of distal radius fractures and injuries of the triangular fibrocartilage complex.

    PubMed

    Kasapinova, K; Kamiloski, V

    2016-06-01

    Our purpose was to determine the correlation of initial radiographic parameters of a distal radius fracture with an injury of the triangular fibrocartilage complex. In a prospective study, 85 patients with surgically treated distal radius fractures were included. Wrist arthroscopy was used to identify and classify triangular fibrocartilage complex lesions. The initial radial length and angulation, dorsal angulation, ulnar variance and distal radioulnar distance were measured. Wrist arthroscopy identified a triangular fibrocartilage complex lesion in 45 patients. Statistical analysis did not identify a correlation with any single radiographic parameter of the distal radius fractures with the associated triangular fibrocartilage complex injuries. The initial radiograph of a distal radius fracture does not predict a triangular fibrocartilage complex injury. III. © The Author(s) 2016.

  2. [Analysis of a three-dimensional finite element model of atlas and axis complex fracture].

    PubMed

    Tang, X M; Liu, C; Huang, K; Zhu, G T; Sun, H L; Dai, J; Tian, J W

    2018-05-22

    Objective: To explored the clinical application of the three-dimensional finite element model of atlantoaxial complex fracture. Methods: A three-dimensional finite element model of cervical spine (FEM/intact) was established by software of Abaqus6.12.On the basis of this model, a three-dimensional finite element model of four types of atlantoaxial complex fracture was established: C(1) fracture (Jefferson)+ C(2) fracture (type Ⅱfracture), Jefferson+ C(2) fracture(type Ⅲfracture), Jefferson+ C(2) fracture(Hangman), Jefferson+ stable C(2) fracture (FEM/fracture). The range of motion under flexion, extension, lateral bending and axial rotation were measured and compared with the model of cervical spine. Results: The three-dimensional finite element model of four types of atlantoaxial complex fracture had the same similarity and profile.The range of motion (ROM) of different segments had different changes.Compared with those in the normal model, the ROM of C(0/1) and C(1/2) in C(1) combined Ⅱ odontoid fracture model in flexion/extension, lateral bending and rotation increased by 57.45%, 29.34%, 48.09% and 95.49%, 88.52%, 36.71%, respectively.The ROM of C(0/1) and C(1/2) in C(1) combined Ⅲodontoid fracture model in flexion/extension, lateral bending and rotation increased by 47.01%, 27.30%, 45.31% and 90.38%, 27.30%, 30.0%.The ROM of C(0/1) and C(1/2) in C(1) combined Hangman fracture model in flexion/extension, lateral bending and rotation increased by 32.68%, 79.34%, 77.62% and 60.53%, 81.20%, 21.48%, respectively.The ROM of C(0/1) and C(1/2) in C(1) combined axis fracture model in flexion/extension, lateral bending and rotation increased by 15.00%, 29.30%, 8.47% and 37.87%, 75.57%, 8.30%, respectively. Conclusions: The three-dimensional finite element model can be used to simulate the biomechanics of atlantoaxial complex fracture.The ROM of atlantoaxial complex fracture is larger than nomal model, which indicates that surgical treatment should be performed.

  3. Preferential pathways in complex fracture systems and their influence on large scale transport

    NASA Astrophysics Data System (ADS)

    Willmann, M.; Mañé, R.; Tyukhova, A.

    2017-12-01

    Many subsurface applications in complex fracture systems require large-scale predictions. Precise predictions are difficult because of the existence of preferential pathways at different scales. The intrinsic complexity of fracture systems increases within fractured sedimentary formations, because also the coupling of fractures and matrix has to be taken into account. This interplay of fracture system and the sedimentary matrix is strongly controlled by the actual fracture aperture of an individual fracture. And an effective aperture cannot be easily be determined because of the preferential pathways along the fracture plane. We investigate the influence of these preferential pathways on large scale solute transport and upscale the aperture. By explicitly modeling flow and particle tracking in individual fractures, we develop a new effective transport aperture, which is weighted by the aperture along the preferential paths, a Lagrangian aperture. We show that this new aperture is consistently larger than existing definitions of effective flow and transport apertures. Finally, we apply our results to a fractured sedimentary formation in Northern Switzerland.

  4. [Treatment of enophthalmos after severe malar-maxillary complex fracture with titanium mesh and high density polyethylene (Medpor)].

    PubMed

    Zhao, Yan-feng; Lu, Ping; Zhou, Xiao-nan; Qu, Chang-feng

    2010-03-01

    To study the surgical management of enophthalmos after severe malar maxillary complex fracture. The X-ray and CT examination were performed before operation to diagnose the orbital fracture and intraorbital tissue displacement. The fractured orbital rim was repositioned intraoperatively, followed by implantation of shaped titanium mesh to rebuild the orbital floor. The Medpor was inserted above the titanium mesh to correct the enophthalmos. From Sept. 2007 to Jan. 2009, 6 cases of enophthalmos after severe malar-maxillary complex fracture were treated. The enophthalmos was corrected or improved obviously in all the patients. The enophthalmos after severe malar-maxillary complex fracture can be corrected or obviously improved. Shaped titanium mesh can be used to rebuild the orbital floor with the Medpor to reconstruct the intraorbital tissue volume.

  5. The clinical presentation and management of zygomatic complex fractures in a Nigeria Teaching Hospital.

    PubMed

    Anyanechi, C E; Charles, E A; Saheeb, B D; Birch, D S

    2012-01-01

    Fractures of the zygomatic complex occur worldwide and are a component part of injuries that can be sustained in the maxillofacial region. The objective was to analyze the clinical presentation and management ofzygomatic complex fractures. This was a prospective study carried out over a period of five years at the University of Calabar Teaching Hospital, Nigeria. Data documented were patients' age, gender, time of presentation, cause and type of fracture, associated head and maxillofacial injuries, clinical features, types of plain radiographs, treatment methods, duration of follow-up and complications. Majority of the patients (n = 81, 63.3%) were in their third and fourth decades of life while the male to female ratio was 20.3:1. Road traffic accident (n = 111, 86.7%) was the most common cause of fracture. Fractures of the zygomatic complex alone (n = 105, 82.0%) were more common than isolated fractures of the arch (n = 13, 10.2%) and combined fractures of the zygomatic complex and arch (n = 10, 7.8%). While multi-disciplinary approach to treatment is important, majority of the fractures were treated by simple elevation and transosseous wire osteosynthesis. Delay in presentation, associated injuries and non-availability of mini-plating technique contributed to the development of complications.

  6. Laboratory investigation of shale rock to identify fracture propagation in vertical direction to bedding

    NASA Astrophysics Data System (ADS)

    Peng, Tan; Yan, Jin; Bing, Hou; Yingcao, Zhou; Ruxin, Zhang; Zhi, Chang; Meng, Fan

    2018-06-01

    Affected by beddings and natural fractures, fracture geometry in the vertical plane is complex in shale formation, which differs from a simple fracture in homogeneous sandstone reservoirs. However, the propagation mechanism of a hydraulic fracture in the vertical plane has not been well understood. In this paper, a true tri-axial pressure machine was deployed for shale horizontal well fracturing simulation experiments of shale outcrops. The effects of multiple factors on hydraulic fracture vertical propagation were studied. The results revealed that hydraulic fracture initiation and propagation displayed four basic patterns in the vertical plane of laminated shale formation. A hydraulic fracture would cross the beddings under the high vertical stress difference between a vertical stress and horizontal minimum stress of 12 MPa, while a hydraulic fracture propagates along the beddings under a low vertical stress difference of 3 MPa. Four kinds of fracture geometry, including a single main fracture, a nonplanar fracture, a complex fracture, and a complex fracture network, were observed due to the combined effects of flow rate and viscosity. Due to the influence of binding strength (or cementing strength) on the fracture communication effects between a hydraulic fracture and the beddings, the opening region of the beddings takes the shape of an ellipse.

  7. A Complex Facial Trauma Case with Multiple Mandibular Fractures and Dentoalveolar Injuries

    PubMed Central

    Zorlu, Sevgi; Cankaya, Abdulkadir Burak; Aktoren, Oya; Gencay, Koray

    2015-01-01

    The principles of management of mandibular fractures differ in children when compared to adults and depend on the specific age-related status of the growing mandible and the developing dentition. This paper presents a case report with a complex facial trauma affecting the mandibular body and condyle region and dentoalveolar complex. Clinical examination revealed soft tissue injuries, limited mouth opening, lateral deviation of the mandible, an avulsed incisor, a subluxated incisor, and a fractured crown. CBCT examination revealed a nondisplaced fracture and an oblique greenstick fracture of the mandibular body and unilateral fracture of the condyle. Closed reduction technique was chosen to manage fractures of the mandible. Favorable healing outcomes on multiple fractures of the mandible throughout the 6-year follow-up period proved the success of the conservative treatment. This case report is important since it presents a variety of pathological sequelae to trauma within one case. PMID:26339511

  8. Hydraulic Fracturing and Production Optimization in Eagle Ford Shale Using Coupled Geomechanics and Fluid Flow Model

    NASA Astrophysics Data System (ADS)

    Suppachoknirun, Theerapat; Tutuncu, Azra N.

    2017-12-01

    With increasing production from shale gas and tight oil reservoirs, horizontal drilling and multistage hydraulic fracturing processes have become a routine procedure in unconventional field development efforts. Natural fractures play a critical role in hydraulic fracture growth, subsequently affecting stimulated reservoir volume and the production efficiency. Moreover, the existing fractures can also contribute to the pressure-dependent fluid leak-off during the operations. Hence, a reliable identification of the discrete fracture network covering the zone of interest prior to the hydraulic fracturing design needs to be incorporated into the hydraulic fracturing and reservoir simulations for realistic representation of the in situ reservoir conditions. In this research study, an integrated 3-D fracture and fluid flow model have been developed using a new approach to simulate the fluid flow and deliver reliable production forecasting in naturally fractured and hydraulically stimulated tight reservoirs. The model was created with three key modules. A complex 3-D discrete fracture network model introduces realistic natural fracture geometry with the associated fractured reservoir characteristics. A hydraulic fracturing model is created utilizing the discrete fracture network for simulation of the hydraulic fracture and flow in the complex discrete fracture network. Finally, a reservoir model with the production grid system is used allowing the user to efficiently perform the fluid flow simulation in tight formations with complex fracture networks. The complex discrete natural fracture model, the integrated discrete fracture model for the hydraulic fracturing, the fluid flow model, and the input dataset have been validated against microseismic fracture mapping and commingled production data obtained from a well pad with three horizontal production wells located in the Eagle Ford oil window in south Texas. Two other fracturing geometries were also evaluated to optimize the cumulative production and for the three wells individually. Significant reduction in the production rate in early production times is anticipated in tight reservoirs regardless of the fracturing techniques implemented. The simulations conducted using the alternating fracturing technique led to more oil production than when zipper fracturing was used for a 20-year production period. Yet, due to the decline experienced, the differences in cumulative production get smaller, and the alternating fracturing is not practically implementable while field application of zipper fracturing technique is more practical and widely used.

  9. Assessment of Surrogate Fractured Rock Networks for Evidence of Complex Behavior

    NASA Astrophysics Data System (ADS)

    Wood, T. R.; McJunkin, T. R.; Podgorney, R. K.; Glass, R. J.; Starr, R. C.; Stoner, D. L.; Noah, K. S.; LaViolette, R. A.; Fairley, J.

    2001-12-01

    A complex system or complex process is -"one whose properties are not fully explained by an understanding of its component parts". Results from field experiments conducted at the Hell's Half-Acre field site (Arco, Idaho) suggest that the flow of water in an unsaturated, fractured medium exhibits characteristics of a complex process. A series of laboratory studies is underway with sufficient rigor to determine if complex behavior observed in the field is in fact a fundamental characteristic of water flow in unsaturated, fractured media. As an initial step, a series of four duplicate experiments has been performed using an array of bricks to simulate fractured, unsaturated media. The array consisted of 12 limestone blocks cut to uniform size (5cm x 7 cm x 30 cm) stacked on end 4 blocks wide and 3 blocks high with the interfaces between adjacent blocks representing 3 vertical fractures intersecting 2 horizontal fractures. Water was introduced at three point sources on the upper boundary of the model at the top of the vertical fractures. Water was applied under constant flux at a rate below the infiltration capacity of the system, thus maintaining unsaturated flow conditions. Water was collected from the lower boundary via fiberglass wicks at the bottom of each fracture. An automated system acquired and processed water inflow and outflow data and time-lapse photographic data during each of the 72-hour tests. From these experiments, we see that a few general statements can be made on the overall advance of the wetting front in the surrogate fracture networks. For instance, flow generally converged with depth to the center fracture in the bottom row of bricks. Another observation is that fracture intersections integrate the steady flow in overlying vertical fractures and allow or cause short duration high discharge pulses or "avalanches" of flow to quickly traverse the fracture network below. Smaller scale tests of single fracture and fracture intersections are underway to evaluate a wide array of unit processes that are believed to contribute to complex behavior. Examples of these smaller scale experiments include the role of fracture intersections in integrating a steady inflow to generate giant fluctuations in network discharge; the influence of microbe growth on flow; and the role of geochemistry in alterations of flow paths. Experiments are planned at the meso and field scale to document and understand the controls on self-organized behavior. Modeling is being conducted in parallel with the experiments to understand how simulations can be improved to capture the complexity of fluid flow in fractured rock vadose zones and to make better predictions of contaminant transport.

  10. A Comprehensive Numerical Model for Simulating Fluid Transport in Nanopores

    PubMed Central

    Zhang, Yuan; Yu, Wei; Sepehrnoori, Kamy; Di, Yuan

    2017-01-01

    Since a large amount of nanopores exist in tight oil reservoirs, fluid transport in nanopores is complex due to large capillary pressure. Recent studies only focus on the effect of nanopore confinement on single-well performance with simple planar fractures in tight oil reservoirs. Its impacts on multi-well performance with complex fracture geometries have not been reported. In this study, a numerical model was developed to investigate the effect of confined phase behavior on cumulative oil and gas production of four horizontal wells with different fracture geometries. Its pore sizes were divided into five regions based on nanopore size distribution. Then, fluid properties were evaluated under different levels of capillary pressure using Peng-Robinson equation of state. Afterwards, an efficient approach of Embedded Discrete Fracture Model (EDFM) was applied to explicitly model hydraulic and natural fractures in the reservoirs. Finally, three fracture geometries, i.e. non-planar hydraulic fractures, non-planar hydraulic fractures with one set natural fractures, and non-planar hydraulic fractures with two sets natural fractures, are evaluated. The multi-well performance with confined phase behavior is analyzed with permeabilities of 0.01 md and 0.1 md. This work improves the analysis of capillarity effect on multi-well performance with complex fracture geometries in tight oil reservoirs. PMID:28091599

  11. A Comprehensive Numerical Model for Simulating Fluid Transport in Nanopores

    NASA Astrophysics Data System (ADS)

    Zhang, Yuan; Yu, Wei; Sepehrnoori, Kamy; di, Yuan

    2017-01-01

    Since a large amount of nanopores exist in tight oil reservoirs, fluid transport in nanopores is complex due to large capillary pressure. Recent studies only focus on the effect of nanopore confinement on single-well performance with simple planar fractures in tight oil reservoirs. Its impacts on multi-well performance with complex fracture geometries have not been reported. In this study, a numerical model was developed to investigate the effect of confined phase behavior on cumulative oil and gas production of four horizontal wells with different fracture geometries. Its pore sizes were divided into five regions based on nanopore size distribution. Then, fluid properties were evaluated under different levels of capillary pressure using Peng-Robinson equation of state. Afterwards, an efficient approach of Embedded Discrete Fracture Model (EDFM) was applied to explicitly model hydraulic and natural fractures in the reservoirs. Finally, three fracture geometries, i.e. non-planar hydraulic fractures, non-planar hydraulic fractures with one set natural fractures, and non-planar hydraulic fractures with two sets natural fractures, are evaluated. The multi-well performance with confined phase behavior is analyzed with permeabilities of 0.01 md and 0.1 md. This work improves the analysis of capillarity effect on multi-well performance with complex fracture geometries in tight oil reservoirs.

  12. Simulation Study of CO2-EOR in Tight Oil Reservoirs with Complex Fracture Geometries

    PubMed Central

    Zuloaga-Molero, Pavel; Yu, Wei; Xu, Yifei; Sepehrnoori, Kamy; Li, Baozhen

    2016-01-01

    The recent development of tight oil reservoirs has led to an increase in oil production in the past several years due to the progress in horizontal drilling and hydraulic fracturing. However, the expected oil recovery factor from these reservoirs is still very low. CO2-based enhanced oil recovery is a suitable solution to improve the recovery. One challenge of the estimation of the recovery is to properly model complex hydraulic fracture geometries which are often assumed to be planar due to the limitation of local grid refinement approach. More flexible methods like the use of unstructured grids can significantly increase the computational demand. In this study, we introduce an efficient methodology of the embedded discrete fracture model to explicitly model complex fracture geometries. We build a compositional reservoir model to investigate the effects of complex fracture geometries on performance of CO2 Huff-n-Puff and CO2 continuous injection. The results confirm that the appropriate modelling of the fracture geometry plays a critical role in the estimation of the incremental oil recovery. This study also provides new insights into the understanding of the impacts of CO2 molecular diffusion, reservoir permeability, and natural fractures on the performance of CO2-EOR processes in tight oil reservoirs. PMID:27628131

  13. Mineback Stimulation Research Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warpinski, N.R.

    The Mineback Stimulation Research Program is a systematic study of hydraulic fracturing and the parameters which influence or control fracture geometry or behavior. Fractures are created near a tunnel complex at DOE's Nevada Test Site and are monitored, instrumented, and mined back to observe the effect of treatment, rock and reservoir properties on the fractures. An initial experiment to measure width and pressure in a hydraulic fracture was completed in FY 1983. The test showed that pressure drops along fractures are much larger than predicted, with the result that fractures are shorter, higher, and wider than present models estimate. Themore » cause of this is the complex morphology of hydraulic fractures, including a hierarchy of roughnesses, multiple stranding, and corners, such as the offsets which occur when natural fractures are intersected. A test to study flow behavior in hydraulic fractures with proppant is proposed for FY 1984. 7 figures.« less

  14. XFEM modeling of hydraulic fracture in porous rocks with natural fractures

    NASA Astrophysics Data System (ADS)

    Wang, Tao; Liu, ZhanLi; Zeng, QingLei; Gao, Yue; Zhuang, Zhuo

    2017-08-01

    Hydraulic fracture (HF) in porous rocks is a complex multi-physics coupling process which involves fluid flow, diffusion and solid deformation. In this paper, the extended finite element method (XFEM) coupling with Biot theory is developed to study the HF in permeable rocks with natural fractures (NFs). In the recent XFEM based computational HF models, the fluid flow in fractures and interstitials of the porous media are mostly solved separately, which brings difficulties in dealing with complex fracture morphology. In our new model the fluid flow is solved in a unified framework by considering the fractures as a kind of special porous media and introducing Poiseuille-type flow inside them instead of Darcy-type flow. The most advantage is that it is very convenient to deal with fluid flow inside the complex fracture network, which is important in shale gas extraction. The weak formulation for the new coupled model is derived based on virtual work principle, which includes the XFEM formulation for multiple fractures and fractures intersection in porous media and finite element formulation for the unified fluid flow. Then the plane strain Kristianovic-Geertsma-de Klerk (KGD) model and the fluid flow inside the fracture network are simulated to validate the accuracy and applicability of this method. The numerical results show that large injection rate, low rock permeability and isotropic in-situ stresses tend to lead to a more uniform and productive fracture network.

  15. Modeling the Interaction Between Hydraulic and Natural Fractures Using Dual-Lattice Discrete Element Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Jing; Huang, Hai; Deo, Milind

    The interaction between hydraulic fractures (HF) and natural fractures (NF) will lead to complex fracture networks due to the branching and merging of natural and hydraulic fractures in unconventional reservoirs. In this paper, a newly developed hydraulic fracturing simulator based on discrete element method is used to predict the generation of complex fracture network in the presence of pre-existing natural fractures. By coupling geomechanics and reservoir flow within a dual lattice system, this simulator can effectively capture the poro-elastic effects and fluid leakoff into the formation. When HFs are intercepting single or multiple NFs, complex mechanisms such as direct crossing,more » arresting, dilating and branching can be simulated. Based on the model, the effects of injected fluid rate and viscosity, the orientation and permeability of NFs and stress anisotropy on the HF-NF interaction process are investigated. Combined impacts from multiple parameters are also examined in the paper. The numerical results show that large values of stress anisotropy, intercepting angle, injection rate and viscosity will impede the opening of NFs.« less

  16. Optimizing for Large Planar Fractures in Multistage Horizontal Wells in Enhanced Geothermal Systems Using a Coupled Fluid and Geomechanics Simulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Xiexiaomen; Tutuncu, Azra; Eustes, Alfred

    Enhanced Geothermal Systems (EGS) could potentially use technological advancements in coupled implementation of horizontal drilling and multistage hydraulic fracturing techniques in tight oil and shale gas reservoirs along with improvements in reservoir simulation techniques to design and create EGS reservoirs. In this study, a commercial hydraulic fracture simulation package, Mangrove by Schlumberger, was used in an EGS model with largely distributed pre-existing natural fractures to model fracture propagation during the creation of a complex fracture network. The main goal of this study is to investigate optimum treatment parameters in creating multiple large, planar fractures to hydraulically connect a horizontal injectionmore » well and a horizontal production well that are 10,000 ft. deep and spaced 500 ft. apart from each other. A matrix of simulations for this study was carried out to determine the influence of reservoir and treatment parameters on preventing (or aiding) the creation of large planar fractures. The reservoir parameters investigated during the matrix simulations include the in-situ stress state and properties of the natural fracture set such as the primary and secondary fracture orientation, average fracture length, and average fracture spacing. The treatment parameters investigated during the simulations were fluid viscosity, proppant concentration, pump rate, and pump volume. A final simulation with optimized design parameters was performed. The optimized design simulation indicated that high fluid viscosity, high proppant concentration, large pump volume and pump rate tend to minimize the complexity of the created fracture network. Additionally, a reservoir with 'friendly' formation characteristics such as large stress anisotropy, natural fractures set parallel to the maximum horizontal principal stress (SHmax), and large natural fracture spacing also promote the creation of large planar fractures while minimizing fracture complexity.« less

  17. Investigation of Stimulation-Response Relationships for Complex Fracture Systems in Enhanced Geothermal Reservoirs

    DOE Data Explorer

    Fu, Pengcheng; Johnson, Scott M.; Carrigan, Charles R.

    2011-01-01

    Hydraulic fracturing is currently the primary method for stimulating low-permeability geothermal reservoirs and creating Enhanced (or Engineered) Geothermal Systems (EGS) with improved permeability and heat production efficiency. Complex natural fracture systems usually exist in the formations to be stimulated and it is therefore critical to understand the interactions between existing fractures and newly created fractures before optimal stimulation strategies can be developed. Our study aims to improve the understanding of EGS stimulation-response relationships by developing and applying computer-based models that can effectively reflect the key mechanisms governing interactions between complex existing fracture networks and newly created hydraulic fractures. In this paper, we first briefly describe the key modules of our methodology, namely a geomechanics solver, a discrete fracture flow solver, a rock joint response model, an adaptive remeshing module, and most importantly their effective coupling. After verifying the numerical model against classical closed-form solutions, we investigate responses of reservoirs with different preexisting natural fractures to a variety of stimulation strategies. The factors investigated include: the in situ stress states (orientation of the principal stresses and the degree of stress anisotropy), pumping pressure, and stimulation sequences of multiple wells.

  18. Complex tibial fracture outcomes following treatment with low-intensity pulsed ultrasound.

    PubMed

    Leung, Kwok-Sui; Lee, Wing-Sze; Tsui, Hon-For; Liu, Paul Po-Lung; Cheung, Wing-Hoi

    2004-03-01

    A clinical study was conducted to investigate the effect of low-intensity pulsed ultrasound (US) stimulation (LIPUS) on the healing of complex tibial fractures. Thirty complex tibial fractures were randomly assigned to the treatment with LIPUS (n = 16) or by a dummy machine (sham-exposed: n = 14). The fractures were immobilized by either internal or external fixations according to the clinical indications. LIPUS was given 20 min/day for 90 days. Fracture healing was monitored by clinical, radiological, densitometric and biochemical assessments. The LIPUS-treated group showed statistically significantly better healing, as demonstrated by all assessments. Complications were minimal in the LIPUS group. There were two cases of delayed union, with one in each group. There were two cases of infection in the control group. The delayed-union cases were subsequently treated by LIPUS and the infection cases were treated with standard protocol. Fracture healing in these patients was again treated by LIPUS.

  19. Hydraulic fracture propagation modeling and data-based fracture identification

    NASA Astrophysics Data System (ADS)

    Zhou, Jing

    Successful shale gas and tight oil production is enabled by the engineering innovation of horizontal drilling and hydraulic fracturing. Hydraulically induced fractures will most likely deviate from the bi-wing planar pattern and generate complex fracture networks due to mechanical interactions and reservoir heterogeneity, both of which render the conventional fracture simulators insufficient to characterize the fractured reservoir. Moreover, in reservoirs with ultra-low permeability, the natural fractures are widely distributed, which will result in hydraulic fractures branching and merging at the interface and consequently lead to the creation of more complex fracture networks. Thus, developing a reliable hydraulic fracturing simulator, including both mechanical interaction and fluid flow, is critical in maximizing hydrocarbon recovery and optimizing fracture/well design and completion strategy in multistage horizontal wells. A novel fully coupled reservoir flow and geomechanics model based on the dual-lattice system is developed to simulate multiple nonplanar fractures' propagation in both homogeneous and heterogeneous reservoirs with or without pre-existing natural fractures. Initiation, growth, and coalescence of the microcracks will lead to the generation of macroscopic fractures, which is explicitly mimicked by failure and removal of bonds between particles from the discrete element network. This physics-based modeling approach leads to realistic fracture patterns without using the empirical rock failure and fracture propagation criteria required in conventional continuum methods. Based on this model, a sensitivity study is performed to investigate the effects of perforation spacing, in-situ stress anisotropy, rock properties (Young's modulus, Poisson's ratio, and compressive strength), fluid properties, and natural fracture properties on hydraulic fracture propagation. In addition, since reservoirs are buried thousands of feet below the surface, the parameters used in the reservoir flow simulator have large uncertainty. Those biased and uncertain parameters will result in misleading oil and gas recovery predictions. The Ensemble Kalman Filter is used to estimate and update both the state variables (pressure and saturations) and uncertain reservoir parameters (permeability). In order to directly incorporate spatial information such as fracture location and formation heterogeneity into the algorithm, a new covariance matrix method is proposed. This new method has been applied to a simplified single-phase reservoir and a complex black oil reservoir with complex structures to prove its capability in calibrating the reservoir parameters.

  20. Epidemiological study of facial fractures at the Oral and Maxillofacial Surgery Service, Santa Casa de Misericordia Hospital Complex, Porto Alegre - RS - Brazil.

    PubMed

    Zamboni, Rodrigo Andrighetti; Wagner, João Carlos Birnfeld; Volkweis, Maurício Roth; Gerhardt, Eduardo Luis; Buchmann, Elissa Muller; Bavaresco, Caren Serra

    2017-01-01

    to investigate the incidence and etiology of face trauma with diagnosis of facial fracture treated at the Buccomaxillofacial Surgery and Traumatology Service of the Santa Casa de Misericórdia Hospital Complex in Porto Alegre. we conducted a cross-sectional, retrospective epidemiological study of 134 trauma victims with 153 facial fractures. the male gender was the most affected (86.6%) and the incidence was higher in the age group from 21 to 30 years. The main etiology was assault (38.8%), followed by motor vehicle accidents (14.2%), motorcycle accidents (13.4%), falls (9%), road accidents (6.7%), sports accidents (5.2%), work accidents (5.2%), firearm injuries (4.5%) and cycling accidents (3%). The most frequent fractures were those of the zygomatic complex (44.5%), followed by fractures of the mandible (42.5%), maxillary bone (5.2%), nasal bones (4.5%) and zygomatic arch (3.3%). the fractures of the zygomatic complex and the mandible were the ones with the highest incidence in the facial traumas, having physical assaults as their main cause.

  1. Fixation of zygomatic and mandibular fractures with biodegradable plates.

    PubMed

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    In this prospective study, 13 randomly selected patients underwent treatment for zygomatic-complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and screws using Champy's principle. All the cases were evaluated clinically and radiologically for the type of fracture, need for the intermaxillary fixation (IMF) and its duration, duration of surgery, fixation at operation, state of reduction at operation, state of bone union after operation, anatomic reduction, paresthesia, occlusal discrepancies, soft tissue infection, immediate and late inflammatory reactions related to biodegradation process, and any need for the removal of the plates. Descriptives, Frequencies, and Chi-square test were used. In our study, the age group range was 5 to 55 years. Road traffic accidents accounted for the majority of patients six, (46.2%). Postoperative occlusal discrepancies were found in seven patients as mild to moderate, which resolved with IMF for 1-8 weeks. There were minimal complications seen and only as soft tissue infection. Use of biodegradable osteosynthesis system is a reliable alternative method for the fixation of zygomatic-complex and mandibular fractures. The biodegradable system still needs to be refined in material quality and handling to match the stability achieved with metal system. Biodegradable plates and screws is an ideal system for pediatric fractures with favorable outcome.

  2. Biomechanical Concepts for Fracture Fixation

    PubMed Central

    Bottlang, Michael; Schemitsch, Christine E.; Nauth, Aaron; Routt, Milton; Egol, Kenneth; Cook, Gillian E.; Schemitsch, Emil H.

    2015-01-01

    Application of the correct fixation construct is critical for fracture healing and long-term stability; however, it is a complex issue with numerous significant factors. This review describes a number of common fracture types, and evaluates their currently available fracture fixation constructs. In the setting of complex elbow instability, stable fixation or radial head replacement with an appropriately sized implant in conjunction with ligamentous repair is required to restore stability. For unstable sacral fractures, “standard” iliosacral screw fixation is not sufficient for fractures with vertical or multiplanar instabilities. Periprosthetic femur fractures, in particular Vancouver B1 fractures, have increased stability when using 90/90 fixation versus a single locking plate. Far Cortical Locking combines the concept of dynamization with locked plating in order to achieve superior healing of a distal femur fracture. Finally, there is no ideal construct for syndesmotic fracture stabilization; however, these fractures should be fixed using a device that allows for sufficient motion in the syndesmosis. In general, orthopaedic surgeons should select a fracture fixation construct that restores stability and promotes healing at the fracture site, while reducing the potential for fixation failure. PMID:26584263

  3. Modelling DC responses of 3D complex fracture networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beskardes, Gungor Didem; Weiss, Chester Joseph

    Here, the determination of the geometrical properties of fractures plays a critical role in many engineering problems to assess the current hydrological and mechanical states of geological media and to predict their future states. However, numerical modeling of geoelectrical responses in realistic fractured media has been challenging due to the explosive computational cost imposed by the explicit discretizations of fractures at multiple length scales, which often brings about a tradeoff between computational efficiency and geologic realism. Here, we use the hierarchical finite element method to model electrostatic response of realistically complex 3D conductive fracture networks with minimal computational cost.

  4. Modelling DC responses of 3D complex fracture networks

    DOE PAGES

    Beskardes, Gungor Didem; Weiss, Chester Joseph

    2018-03-01

    Here, the determination of the geometrical properties of fractures plays a critical role in many engineering problems to assess the current hydrological and mechanical states of geological media and to predict their future states. However, numerical modeling of geoelectrical responses in realistic fractured media has been challenging due to the explosive computational cost imposed by the explicit discretizations of fractures at multiple length scales, which often brings about a tradeoff between computational efficiency and geologic realism. Here, we use the hierarchical finite element method to model electrostatic response of realistically complex 3D conductive fracture networks with minimal computational cost.

  5. Are recent graduates of orthopaedic training programs performing less fracture care? American Board of Orthopedic Surgeons part II: a quality improvement initiative.

    PubMed

    Koval, Kenneth J; Marsh, Larry; Anglen, Jeff; Weinstein, James; Harrast, John J

    2012-03-01

    The purpose of this study was to evaluate whether there has been a change in the amount of fracture care performed by recent graduates of orthopaedic residency programs over time. Retrospective review. American Board of Orthopaedic Surgery (ABOS) Part II database. Candidates applying for Part II of the second part of the Orthopaedic (ABOS) certification. The ABOS Part II database was searched from years 1999 to 2008 for Current Procedural Terminology codes indicating 1) "simpler fractures" that any candidate surgeon should be able to perform; 2) "complex fractures" that are often referred to surgeons with specialty training; and 3) "emergent cases" that should be done emergently by a physician. Logistic regression and chi-square tests were used to evaluate whether there has been a change in the amount of fracture care among recent graduates of orthopaedic residency programs over time. Over the 10-year period (1999-2008), a total of 95,922 cases were in the simpler fractures category; 16,523 were classified as complex fractures and 17,789 were classified as emergent cases. The overall number of cases by fracture type increased from 1999 to 2008 as did the average number of surgery cases performed by surgeons in each category over the 6-month collection period. Simpler fracture cases increased 18% (8304-9784 cases) with the average number surgically treated by surgeons performing at least one simple fracture case also increasing 18% (14.1-16.6 cases per surgeon). Complex fracture cases increased 51% (1266-1916 cases) with the average number of these cases per surgeon operating at least one complex fracture case increasing 52% (3.3-5.0 cases per surgeon). Emergent fracture cases increased 92% (1178-2264 cases) with the average number of these cases per surgeon operating at least one emergent fracture case increasing 49% (4.5-6.7 cases per surgeon). From the data presented here, candidate orthopaedic surgeons are treating fractures as least as often as young surgeons were 10 years ago.

  6. Applications of Automation Methods for Nonlinear Fracture Test Analysis

    NASA Technical Reports Server (NTRS)

    Allen, Phillip A.; Wells, Douglas N.

    2013-01-01

    As fracture mechanics material testing evolves, the governing test standards continue to be refined to better reflect the latest understanding of the physics of the fracture processes involved. The traditional format of ASTM fracture testing standards, utilizing equations expressed directly in the text of the standard to assess the experimental result, is self-limiting in the complexity that can be reasonably captured. The use of automated analysis techniques to draw upon a rich, detailed solution database for assessing fracture mechanics tests provides a foundation for a new approach to testing standards that enables routine users to obtain highly reliable assessments of tests involving complex, non-linear fracture behavior. Herein, the case for automating the analysis of tests of surface cracks in tension in the elastic-plastic regime is utilized as an example of how such a database can be generated and implemented for use in the ASTM standards framework. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.

  7. Influence of natural fractures on hydraulic fracture propagation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teufel, L.W.; Warpinski, N.R.

    Hydraulic fracturing has become a valuable technique for the stimulation of oil, gas, and geothermal reservoirs in a variety of reservoir rocks. In many applications, only short fractures are needed for economic production. In low-permeability reservoirs, however, long penetrating fractures are generally needed, and in this case, natural fractures can be the cause of many adverse effects during a fracture treatment. Natural fractures can influence the overall geometry and effectiveness of the hydraulic fracture by: (1) arresting the vertical or lateral growth, (2) reducing total fracture length via fluid leakoff, (3) limiting proppant transport and placement, and (4) enhancing themore » creation of multiple or secondary fractures rather than a single planar hydraulic fracture. The result may range from negligible to catastrophic depending on the values of the ancillary treatment and reservoir parameters, such as the treating pressure, in-situ stresses, pore pressure, orientations of the natural fractures relative to principal in-situ stresses, spacing and distribution of the natural fractures, permeability, etc. Field observations from mineback experiments at DOE's Nevada Test Site and the multiwell experiment in Colorado, laboratory tests, and analyses of these data are integrated to describe the complex fracture behavior found and to provide guidelines for predicting when this complex fracturing will occur.« less

  8. Influence of natural fractures on hydraulic fracture propagation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teufel, L.W.; Warpinski, N.R.

    Hydraulic fracturing has become a valuable technique for the stimulation of oil, gas, and geothermal reservoirs in a variety of reservoir rocks. In many applications, only short fractures are needed for economic production. In low-permeability reservoirs, however, long penetrating fractures are generally needed, and in this case, natural fractures can be the cause of many adverse effects during a fracture treatment. Natural fractures can influence the overall geometry and effectiveness of the hydraulic fracture by: (1) arresting the vertical or lateral growth, (2) reducing total fracture length via fluid leakoff, (3) limiting proppant transport and placement, and (4) enhancing themore » creation of multiple or secondary fractures rather than a single planar hydraulic fracture. The result may range from negligible to catastrophic depending on the values of the ancillary treatment and reservoir parameters, such as the treating pressure, in-situ stresses, pore pressure, orientations of the natural fractures relative to principle in-situ stresses, spacing and distribution of the natural fractures, permeability, etc. Field observations from mineback experiments at DOE's Nevada Test Site and the multiwell experiment in Colorado, laboratory tests, and analyses of these data are integrated to describe the complex fracture behavior found to an provide guidelines for predicting when this complex fracturing occurs.« less

  9. Slow Recovery of Weight Bearing After Stabilization of Long-Bone Fractures Using Elastic Stable Intramedullary Nails in Children

    PubMed Central

    Lardelli, Patrizia; Frech-Dörfler, Martina; Holland-Cunz, Stefan; Mayr, Johannes

    2016-01-01

    Abstract Stabilization of diaphyseal long-bone fractures using elastic stable intramedullary nails (ESIN) in children promises early mobilization and rapid resumption of full weight bearing. We evaluated the duration of postoperative functional rehabilitation after ESIN, measured by the time from stabilization until first partial weight bearing, full weight bearing, and resumption of school sports. Fifty children with unstable, displaced fractures of the femur or lower leg treated with ESIN between 2002 and 2012 were included in this retrospective analysis. We classified fractures according to the pediatric comprehensive classification of fractures (PCCF). Thirty-five children sustained a femur fracture, and 15 children had a fracture of the lower leg or tibia. The surgeons in charge applied an additional plaster cast in 7 of 15 children who suffered a lower leg fracture. The postoperative time interval until full weight bearing in the group of children who had suffered transverse or short oblique femur fractures was significantly shorter (median: 4.4 weeks; range: 0.1–9.1 weeks) than that in the group who had sustained more complex fracture patterns (median: 6.8 weeks; range: 2.9–13.9 weeks; P = 0.04). Similarly, transverse and short oblique lower leg and tibia fractures required less time until full weight bearing (median: 4.1 weeks; range 2.7–6.0 weeks) than complex lower leg fractures (median: 6.1 weeks; range: 1.3–12.9 weeks; P = 0.04). ESIN proved fairly effective in restoring full weight bearing in transverse or short oblique fractures of the lower extremities but was less effective in complex fractures. PMID:26986106

  10. Slow Recovery of Weight Bearing After Stabilization of Long-Bone Fractures Using Elastic Stable Intramedullary Nails in Children.

    PubMed

    Lardelli, Patrizia; Frech-Dörfler, Martina; Holland-Cunz, Stefan; Mayr, Johannes

    2016-03-01

    Stabilization of diaphyseal long-bone fractures using elastic stable intramedullary nails (ESIN) in children promises early mobilization and rapid resumption of full weight bearing. We evaluated the duration of postoperative functional rehabilitation after ESIN, measured by the time from stabilization until first partial weight bearing, full weight bearing, and resumption of school sports. Fifty children with unstable, displaced fractures of the femur or lower leg treated with ESIN between 2002 and 2012 were included in this retrospective analysis. We classified fractures according to the pediatric comprehensive classification of fractures (PCCF). Thirty-five children sustained a femur fracture, and 15 children had a fracture of the lower leg or tibia. The surgeons in charge applied an additional plaster cast in 7 of 15 children who suffered a lower leg fracture. The postoperative time interval until full weight bearing in the group of children who had suffered transverse or short oblique femur fractures was significantly shorter (median: 4.4 weeks; range: 0.1-9.1 weeks) than that in the group who had sustained more complex fracture patterns (median: 6.8 weeks; range: 2.9-13.9 weeks; P = 0.04). Similarly, transverse and short oblique lower leg and tibia fractures required less time until full weight bearing (median: 4.1 weeks; range 2.7-6.0 weeks) than complex lower leg fractures (median: 6.1 weeks; range: 1.3-12.9 weeks; P = 0.04). ESIN proved fairly effective in restoring full weight bearing in transverse or short oblique fractures of the lower extremities but was less effective in complex fractures.

  11. Fixation of zygomatic and mandibular fractures with biodegradable plates

    PubMed Central

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    Context: In this prospective study, 13 randomly selected patients underwent treatment for zygomatic–complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. Aims: To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. Materials and Methods: In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and screws using Champy's principle. All the cases were evaluated clinically and radiologically for the type of fracture, need for the intermaxillary fixation (IMF) and its duration, duration of surgery, fixation at operation, state of reduction at operation, state of bone union after operation, anatomic reduction, paresthesia, occlusal discrepancies, soft tissue infection, immediate and late inflammatory reactions related to biodegradation process, and any need for the removal of the plates. Statistical Analysis Used: Descriptives, Frequencies, and Chi-square test were used. Results: In our study, the age group range was 5 to 55 years. Road traffic accidents accounted for the majority of patients six, (46.2%). Postoperative occlusal discrepancies were found in seven patients as mild to moderate, which resolved with IMF for 1-8 weeks. There were minimal complications seen and only as soft tissue infection. Conclusions: Use of biodegradable osteosynthesis system is a reliable alternative method for the fixation of zygomatic-complex and mandibular fractures. The biodegradable system still needs to be refined in material quality and handling to match the stability achieved with metal system. Biodegradable plates and screws is an ideal system for pediatric fractures with favorable outcome. PMID:23662255

  12. Recent developments in analysis of crack propagation and fracture of practical materials

    NASA Technical Reports Server (NTRS)

    Hardrath, H. F.; Newman, J. C., Jr.; Elber, W.; Poe, C. C., Jr.

    1978-01-01

    Present U.S. Air Force and proposed U.S. civil airworthiness regulations are based on considerations of 'damage tolerance' in aircraft structures. Airworthiness is assured by demonstrating that damage that escapes one in a sequence of periodic inspections will not grow to critical size before the next inspection. The evaluations conducted employ fracture mechanics analyses. Problems arise because the features of fracture mechanics applications related to aircraft structures are more complex than the cases of fracture mechanics which have been mainly investigated. NASA has, therefore, conducted a variety of research tasks to extend the capabilities of fracture mechanics to deal with some of these complexities. The current stage of development of these capabilities is described. Attention is given to the limitations of linear elastic fracture mechanics, a two-parameter fracture criterion, aspects of fatigue crack propagation, and crack propagation and fracture in built-up structures.

  13. Pediatric maxillofacial fractures.

    PubMed

    Spring, P M; Cote, D N

    1996-05-01

    Maxillofacial trauma in the pediatric population is a relatively infrequent occurrence. Studies have demonstrated consistently that 5% of all facial fractures occur in children. The low percentage of facial fractures in this age group has been attributed, in part, to the lack of full pneumatization of the sinuses until later in childhood. Review of the literature indicates that boys are more commonly affected than girls and that the majority of pediatric facial fractures occur in children between 6 and 12 years of age. Motor vehicle accidents, falls, and blunt trauma are responsible for the largest number of pediatric facial fractures. The most common site of facial fracture is the nose and dentoalveolan complex, followed by the mandible, orbit, and midface in most pediatric cohorts. Management of the mandible is often conservative owing to the high percentage of isolated condylar fractures in children. Open reduction and internal fixation of pediatric facial fractures is indicated in complex mandible, midface, and orbital fractures. The effect of rigid fixation on facial skeleton growth is not completely understood.

  14. Multi-scale Fracture Patterns Associated with a Complex Anticline Structure: Insights from Field Outcrop Analogues of the Jebel Hafit Pericline, Al Ain-UAE

    NASA Astrophysics Data System (ADS)

    Kokkalas, S.; Jones, R. R.; Long, J. J.; Zampos, M.; Wilkinson, M. W.; Gilment, S.

    2017-12-01

    The formation of folds and their associated fracture patterns plays an important role in controlling the migration and concentration of fluids within the upper crust. Prediction of fracture patterns from various fold shapes and kinematics still remains poorly understood in terms of spatial and temporal distribution of fracture sets. Thus, a more detailed field-based multi scale approach is required to better constrain 3D models of fold-fracture relationships, which are critical for reservoir characterization studies. In order to generate reservoir-scale fracture models representative fracture properties across a wider range of scales are needed. For this reason we applied modern geospatial technologies, including terrestrial LiDAR, photogrammetry and satellite images in the asymmetric, east verging, four-way closure Jebel Hafit anticline, in the eastern part of the United Arab Emirates. The excellent surface outcrops allowed the rapid acquisition of extensive areas of fracture data from both limbs and fold hinge area of the anticline, even from large areas of steep exposure that are practically inaccessible on foot. The digital outcrops provide longer 1D transects, and 2D or 3D surface datasets and give more robust data, particularly for fracture heights, lengths, spacing, clustering, termination and connectivity. The fracture patterns across the folded structure are more complex than those predicted from conceptual models and geomechanical fracture modeling. Mechanical layering, pre-existing structures and sedimentation during fold growth seem to exert a critical influence in the development of fracture systems within Jebel Hafit anticline and directly affect fracture orientations, spacing/intensity, segmentation and connectivity. Seismic and borehole data provide additional constraints on the sub-surface fold geometry and existence of large-scale thrusting in the core of the anticline. The complexity of the relationship between fold geometry and fracture intensity is presented and the implications for prediction of fracture networks in naturally fractured reservoirs are discussed.

  15. [Arthroscopically Assisted Minimally Invasive Fixation of a Type D2c Scapular Fracture].

    PubMed

    Kornherr, Patrick; Konerding, Christiane; Kovacevic, Mark; Wenda, Klaus

    2018-06-12

    Fractures of the scapula are rare and have an incidence of 1% of all fractures. Publications highlight glenoid rim fractures. Classification by Ideberg and Euler and Rüdi are accepted. Euler and Rüdi describe three extra-articular and two intra-articular fracture patterns. The indications for surgery are displaced glenoid fractures, scapula tilt of more than 40° and injuries to the superior shoulder suspensory complex. We describe a case of a 22 year old man, who while cycling collided with a moving car due to wet roads. After his admission to hospital as a polytraumatised patient, the trauma CT-Scan showed haemothorax with several associated rip fractures, displaced humeral shaft fracture and fractures of the acromion and glenoid, classified as type D2c according to Euler and Rüdi. Following damage control principles, drainage of the haemothorax was already performed in the ER and surgical treatment of the displaced humeral shaft fracture was performed on the day of admission. No peripheral neurological deficits were evident. After pulmonary stabilisation, surgery was performed 6 days later on the glenoid and acromion fracture, which in conjunction may be regarded as an injury to the superior shoulder suspensory complex. We performed an arthroscopically-assisted screw fixation of the glenoid fracture (type D2c according to Euler and Rüdi) and an ORIF procedure at the acromion. Postoperative rehabilitation was performed with passive abduction and elevation up to 90° for the first two weeks and active abduction an elevation up to 90° for weeks 3 to 6. Full ROM was allowed at week 7. Articular fractures of the glenoid are rare and mainly seen as rim fractures. The indications for surgery are displaced articular fractures and injury to the superior shoulder suspensory complex. As demonstrated by this article, type D2c fractures according to Euler and Rüdi can be treated effectively as an arthroscopically-assisted screw fixation procedure. Georg Thieme Verlag KG Stuttgart · New York.

  16. Annual National Test and Evaluation Conference (27th) Held in Tampa, Florida on March 14-17, 2011

    DTIC Science & Technology

    2011-03-17

    Based Test & Evaluation PETALLINGFRAGMENTATION RADIAL FRACTUREBRITTLE FRACTURE DUCTILE HOLE GROWTH PLUGGING THREAT VELOCITY MATERIAL MATERIAL V50 TYPE...Less Complex Less Costly Testing More Complex More Costly PETALLINGFRAGMENTATION RADIAL FRACTUREBRITTLE FRACTURE DUCTILE HOLE GROWTH PLUGGING...Reversible injuries; medical attention required 3 Serious Fracture of skull, penetration < 2 cm Reversible injuries; hospitalization required 4 Severe

  17. The value of arthroscopy in the treatment of complex ankle fractures - a protocol of a randomised controlled trial.

    PubMed

    Braunstein, Mareen; Baumbach, Sebastian F; Regauer, Markus; Böcker, Wolfgang; Polzer, Hans

    2016-05-12

    An anatomical reconstruction of the ankle congruity is the important prerequisite in the operative treatment of acute ankle fractures. Despite anatomic restoration patients regularly suffer from residual symptoms after these fractures. There is growing evidence, that a poor outcome is related to the concomitant traumatic intra-articular pathology. By supplementary ankle arthroscopy anatomic reduction can be confirmed and associated intra-articular injuries can be treated. Nevertheless, the vast majority of complex ankle fractures are managed by open reduction and internal fixation (ORIF) only. Up to now, the effectiveness of arthroscopically assisted fracture treatment (AORIF) has not been conclusively determined. Therefore, a prospective randomised study is needed to sufficiently evaluate the effect of AORIF compared to ORIF in complex ankle fractures. We perform a randomised controlled trial at Munich University Clinic enrolling patients (18-65 years) with an acute ankle fracture (AO 44 A2, A3, B2, B3, C1 - C3 according to AO classification system). Patients meeting the inclusion criteria are randomised to either intervention group (AORIF, n = 37) or comparison group (ORIF, n = 37). Exclusion criteria are fractures classified as AO type 44 A1 or B1, pilon or plafond-variant injury or open fractures. Primary outcome is the AOFAS Score (American Orthopaedic Foot and Ankle Society). Secondary outcome parameter are JSSF Score (Japanese Society of Surgery of the Foot), Olerud and Molander Score, Karlsson Score, Tegner Activity Scale, SF-12, radiographic analysis, arthroscopic findings of intra-articular lesions, functional assessments, time to return to work/sports and complications. This study protocol is accordant to the SPIRIT 2013 recommendation. Statistical analysis will be performed using SPSS 22.0 (IBM). The subjective and functional outcome of complex ankle fractures is regularly unsatisfying. As these injuries are very common it is essential to improve the postoperative results. Potentially, arthroscopically assisted fracture treatment can significantly improve the outcome by addressing the intra-articular pathologies. Given the absolute lack of studies comparing AORIF to ORIF in complex ankle fractures, this randomised controlled trail is urgently needed to evaluate the effectiveness of additional arthroscopy. ClinicalTrials.gov reference: NCT02449096 (Trial registration date: April 7th, 2015).

  18. The Role of the Rock on Hydraulic Fracturing of Tight Shales

    NASA Astrophysics Data System (ADS)

    Suarez-Rivera, R.; Green, S.; Stanchits, S.; Yang, Y.

    2011-12-01

    Successful economic production of oil and gas from nano-darcy-range permeability, tight shale reservoirs, is achieved via massive hydraulic fracturing. This is so despite their limited hydrocarbon in place, on per unit rock volume basis. As a reference, consider a typical average porosity of 6% and an average hydrocarbon saturation of 50% to 75%. The importance of tight shales results from their large areal extent and vertical thickness. For example, the areal extent of the Anwar field in Saudi Arabia of 3230 square miles (and 300 ft thick), while the Marcellus shale alone is over 100,000 square miles (and 70 to 150 ft thick). The low permeability of the rock matrix, the predominantly mineralized rock fabric, and the high capillary forces to both brines and hydrocarbons, restrict the mobility of pore fluids in these reservoirs. Thus, one anticipates that fluids do not move very far within tight shales. Successful production, therefore results from maximizing the surface area of contact with the reservoir by massive hydraulic fracturing from horizontal bore holes. This was the conceptual breakthrough of the previous decade and the one that triggered the emergence of gas shales, and recently oily shales, as important economic sources of energy. It is now understood that the process can be made substantially more efficient, more sustainable, and more cost effective by understanding the rock. This will be the breakthrough of this decade. Microseismic monitoring, mass balance calculations, and laboratory experiments of hydraulic fracturing on tight shales indicate the development of fracture complexity and fracture propagation that can not be explained in detail in this layered heterogeneous media. It is now clear that in tight shales the large-scale formation fabric is responsible for fracture complexity. For example, the presence and pervasiveness of mineralized fractures, bed interfaces, lithologic contacts, and other types of discontinuities, and their orientation in relation to the in-situ stresses, have a dominant role in promoting fracture branching and abrupt changes in direction. In general, the problem can be conceptualized as a competition between the effect of stresses (traditional mechanics of homogeneous media) and the effect of rock fabric (the mechanics of heterogeneous media). When the stress difference is low and the rock fabric pronounced, the rock fabric defines the direction of propagation. When the stress difference is high and the fabric is weak, the stress contrast dominates the process. In real systems, both effects compete and result in the complexity that we infer from indirect observations. In this paper we discuss the role of rock fabric on fracture complexity during hydraulic fracture propagation. We show that understanding the far field stresses is not enough to understand fracture propagation and complexity. Understanding the rock-specifically the larger-scale textural features that define the reservoir fabric-is fundamental to understand fracture complexity and fracture containment. We use laboratory experiments with acoustic emission localization to monitor fracturing and making inferences about the large-scale rock behavior. We also show that the fracture geometry, even for the same connected surface area, has significant well production and reservoir recovery implications.

  19. Hydraulic Fracturing Mineback Experiment in Complex Media

    NASA Astrophysics Data System (ADS)

    Green, S. J.; McLennan, J. D.

    2012-12-01

    Hydraulic fracturing (or "fracking") for the recovery of gas and liquids from tight shale formations has gained much attention. This operation which involves horizontal well drilling and massive hydraulic fracturing has been developed over the last decade to produce fluids from extremely low permeability mudstone and siltstone rocks with high organic content. Nearly thirteen thousand wells and about one hundred and fifty thousand stages within the wells were fractured in the US in 2011. This operation has proven to be successful, causing hundreds of billions of dollars to be invested and has produced an abundance of natural gas and is making billions of barrels of hydrocarbon liquids available for the US. But, even with this commercial success, relatively little is clearly known about the complexity--or lack of complexity--of the hydraulic fracture, the extent that the newly created surface area contacts the high Reservoir Quality rock, nor the connectivity and conductivity of the hydraulic fractures created. To better understand this phenomena in order to improve efficiency, a large-scale mine-back experiment is progressing. The mine-back experiment is a full-scale hydraulic fracture carried out in a well-characterized environment, with comprehensive instrumentation deployed to measure fracture growth. A tight shale mudstone rock geologic setting is selected, near the edge of a formation where one to two thousand feet difference in elevation occurs. From the top of the formation, drilling, well logging, and hydraulic fracture pumping will occur. From the bottom of the formation a horizontal tunnel will be mined using conventional mining techniques into the rock formation towards the drilled well. Certain instrumentation will be located within this tunnel for observations during the hydraulic fracturing. After the hydraulic fracturing, the tunnel will be extended toward the well, with careful mapping of the created hydraulic fracture. Fracturing fluid will be traceable, as will injected proppant, in order to demarcate in-situ fracture paths and fluid and proppant progression. This underground experiment is referred to as a "mine-back experiment". Several mine-back experiments have been conducted in the past, and have demonstrated complex, diffuse fracture systems in coals and bundled fracture systems in some sandstones. No mine-back experiment has been conducted in the tight shales; but, economics and environmental considerations dictate that more definitive measurements will be extremely helpful to establish fracture growth patterns and to validate monitoring methods such as micro-seismic measurements. This presentation discusses the mine-back experiment and presents details of geologic setting, hydraulic fracturing, and the excavation required before and after the hydraulic fracture. The mine-back experiment will provide ground-truth assessment of hydraulic fracturing, geologic forecasting, micro-seismicity, and other information.

  20. Modeling propellant-based stimulation of a borehole with peridynamics

    DOE PAGES

    Panchadhara, Rohan; Gordon, Peter A.; Parks, Michael L.

    2017-02-27

    A non-local formulation of classical continuum mechanics theory known as peridynamics is used to study fracture initiation and growth from a wellbore penetrating the subsurface within the context of propellant-based stimulation. The principal objectives of this work are to analyze the influence of loading conditions on the resulting fracture pattern, to investigate the effect of in-situ stress anisotropy on fracture propagation, and to assess the suitability of peridynamics for modeling complex fracture formation. In peridynamics, the momentum equation from the classical theory of solid mechanics is replaced by a non-local analogue, which results in an integrodifferential conservation equation. A continuummore » material is discretized with a set of material points that interact with all other points within a specified distance. Interactions between points are governed by bonds that can deform and break depending on loading conditions. The accumulated breakage of bonds gives rise to a picture of complex growth of fractures that is seen as a key advantage in the peridynamic representation of discontinuities. It is shown that the loading rate significantly influences the number and ex- tent of fractures initiated from a borehole. Results show that low loading rates produce fewer but longer fractures, whereas high loading rates produce numerous shorter fractures around the borehole. The numerical method is able to predict fracture growth patterns over a wide range of loading and stress conditions. Our results also show that fracture growth is attenuated with increasing in-situ confining stress, and, in the case of confining stress anisotropy, fracture extensions are largest in the direction perpendicular to the minimum compressive stress. Since the results are in broad qualitative agreement with experimental and numerical studies found in the literature, suggesting that peridynamics can be a powerful tool in the study of complex fracture network formation.« less

  1. Modeling propellant-based stimulation of a borehole with peridynamics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panchadhara, Rohan; Gordon, Peter A.; Parks, Michael L.

    A non-local formulation of classical continuum mechanics theory known as peridynamics is used to study fracture initiation and growth from a wellbore penetrating the subsurface within the context of propellant-based stimulation. The principal objectives of this work are to analyze the influence of loading conditions on the resulting fracture pattern, to investigate the effect of in-situ stress anisotropy on fracture propagation, and to assess the suitability of peridynamics for modeling complex fracture formation. In peridynamics, the momentum equation from the classical theory of solid mechanics is replaced by a non-local analogue, which results in an integrodifferential conservation equation. A continuummore » material is discretized with a set of material points that interact with all other points within a specified distance. Interactions between points are governed by bonds that can deform and break depending on loading conditions. The accumulated breakage of bonds gives rise to a picture of complex growth of fractures that is seen as a key advantage in the peridynamic representation of discontinuities. It is shown that the loading rate significantly influences the number and ex- tent of fractures initiated from a borehole. Results show that low loading rates produce fewer but longer fractures, whereas high loading rates produce numerous shorter fractures around the borehole. The numerical method is able to predict fracture growth patterns over a wide range of loading and stress conditions. Our results also show that fracture growth is attenuated with increasing in-situ confining stress, and, in the case of confining stress anisotropy, fracture extensions are largest in the direction perpendicular to the minimum compressive stress. Since the results are in broad qualitative agreement with experimental and numerical studies found in the literature, suggesting that peridynamics can be a powerful tool in the study of complex fracture network formation.« less

  2. [Triple fracture of the shoulder suspensory complex].

    PubMed

    Tamimi Mariño, I; Martin Rodríguez, I; Mora Villadeamigo, J

    2013-01-01

    The superior suspensory complex of the shoulder (SSCS) is a ring shaped structure composed of bones and soft tissues that play a fundamental role in the stability of the shoulder joint. Isolated injuries of the SSCS are relatively common, but injuries that affect 3 components are extremely unusual. We present a triple injury of the SSCS in a 26 year old patient with a Neer type ii clavicular fracture, a Kuhn type iii acromion fracture and an Ogawa type i coracoid fracture. An open reduction and stabilization of the clavicle was performed with 2 Kirschner nails. The acromial fracture was synthesized with 2 cannulated screws, and the coracoid fracture was treated conservatively. After 24 months of follow up the patient had an excellent functional outcome according to the Constat-Murley shoulder score and QuickDASH scoring system, and all the fractures healed correctly. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  3. Modeling OPC complexity for design for manufacturability

    NASA Astrophysics Data System (ADS)

    Gupta, Puneet; Kahng, Andrew B.; Muddu, Swamy; Nakagawa, Sam; Park, Chul-Hong

    2005-11-01

    Increasing design complexity in sub-90nm designs results in increased mask complexity and cost. Resolution enhancement techniques (RET) such as assist feature addition, phase shifting (attenuated PSM) and aggressive optical proximity correction (OPC) help in preserving feature fidelity in silicon but increase mask complexity and cost. Data volume increase with rise in mask complexity is becoming prohibitive for manufacturing. Mask cost is determined by mask write time and mask inspection time, which are directly related to the complexity of features printed on the mask. Aggressive RET increase complexity by adding assist features and by modifying existing features. Passing design intent to OPC has been identified as a solution for reducing mask complexity and cost in several recent works. The goal of design-aware OPC is to relax OPC tolerances of layout features to minimize mask cost, without sacrificing parametric yield. To convey optimal OPC tolerances for manufacturing, design optimization should drive OPC tolerance optimization using models of mask cost for devices and wires. Design optimization should be aware of impact of OPC correction levels on mask cost and performance of the design. This work introduces mask cost characterization (MCC) that quantifies OPC complexity, measured in terms of fracture count of the mask, for different OPC tolerances. MCC with different OPC tolerances is a critical step in linking design and manufacturing. In this paper, we present a MCC methodology that provides models of fracture count of standard cells and wire patterns for use in design optimization. MCC cannot be performed by designers as they do not have access to foundry OPC recipes and RET tools. To build a fracture count model, we perform OPC and fracturing on a limited set of standard cells and wire configurations with all tolerance combinations. Separately, we identify the characteristics of the layout that impact fracture count. Based on the fracture count (FC) data from OPC and mask data preparation runs, we build models of FC as function of OPC tolerances and layout parameters.

  4. [Treatment of complex scapular body fractures by locking reconstructive plates].

    PubMed

    Zhang, Jun-wei; Hou, Jin-yong; Yang, Mao-qing

    2011-03-01

    To investigate the method and effect of treatment of complex scapular body fractures by locking reconstructive plate through modified posterior approach. From August 2005 to November 2009, 27 patients with complex scapula body fractures were treated by locking reconstruction bone plate fixation,including 19 males and 8 females with an average age of 36 years old ranging from 16 to 64 years. The time after injury was 0.5 hours to 11 days (averaged 3 days). Of all the patients, 9 cases were associated with ipsilateral clavicle fracture, 2 cases were associated with acromioclavicular joint dislocation,16 cases were associated with multiple rib fractures, 1 case were associated with humeral shaft fractures, 5 cases were associated with pleural effusion, atelectasis, lung contusion etc. After operating,shoulder functional recovery were followed up. Twenty-four patients were followed up from 2 to 35 months with an average of 19 months. According to Hardegger shoulder function,the results were excellent in 15 cases, good in 7 cases, general in 2 cases. This method had the advantage of less trauma and clear exposure, firm and reliable fixation, and early activities.

  5. [Application of three-dimensional printing personalized acetabular wing-plate in treatment of complex acetabular fractures via lateral-rectus approach].

    PubMed

    Mai, J G; Gu, C; Lin, X Z; Li, T; Huang, W Q; Wang, H; Tan, X Y; Lin, H; Wang, Y M; Yang, Y Q; Jin, D D; Fan, S C

    2017-03-01

    Objective: To investigate reduction and fixation of complex acetabular fractures using three-dimensional (3D) printing technique and personalized acetabular wing-plate via lateral-rectus approach. Methods: From March to July 2016, 8 patients with complex acetabular fractures were surgically managed through 3D printing personalized acetabular wing-plate via lateral-rectus approach at Department of Orthopedics, the Third Affiliated Hospital of Southern Medical University. There were 4 male patients and 4 female patients, with an average age of 57 years (ranging from 31 to 76 years). According to Letournel-Judet classification, there were 2 anterior+ posterior hemitransverse fractures and 6 both-column fractures, without posterior wall fracture or contralateral pelvic fracture. The CT data files of acetabular fracture were imported into the computer and 3D printing technique was used to print the fractures models after reduction by digital orthopedic technique. The acetabular wing-plate was designed and printed with titanium. All fractures were treated via the lateral-rectus approach in a horizontal position after general anesthesia. The anterior column and the quadrilateral surface fractures were fixed by 3D printing personalized acetabular wing-plate, and the posterior column fractures were reduction and fixed by antegrade lag screws under direct vision. Results: All the 8 cases underwent the operation successfully. Postoperative X-ray and CT examination showed excellent or good reduction of anterior and posterior column, without any operation complications. Only 1 case with 75 years old was found screw loosening in the pubic bone with osteoporosis after 1 month's follow-up, who didn't accept any treatment because the patient didn't feel discomfort. According to the Matta radiological evaluation, the reduction of the acetabular fracture was rated as excellent in 3 cases, good in 4 cases and fair in 1 case. All patients were followed up for 3 to 6 months and all patients had achieved bone union. According to the modified Merle D'Aubigné and Postel scoring system, 5 cases were excellent, 2 cases were good, 1 case was fair. Conclusions: Surgical management of complex acetabular fracture via lateral-rectus approach combine with 3D printing personalized acetabular wing-plate can effectively improve reduction quality and fixation effect. It will be truly accurate, personalized and minimally invasive.

  6. Surgery for scapula process fractures

    PubMed Central

    Anavian, Jack; Wijdicks, Coen A; Schroder, Lisa K; Vang, Sandy

    2009-01-01

    Background Generally, scapula process fractures (coracoid and acromion) have been treated nonoperatively with favorable outcome, with the exception of widely displaced fractures. Very little has been published, however, regarding the operative management of such fractures and the literature that is available involves very few patients. Our hypothesis was that operative treatment of displaced acromion and coracoid fractures is a safe and effective treatment that yields favorable surgical results. Methods We reviewed 26 consecutive patients (27 fractures) treated between 1998 and 2007. Operative indications for these process fractures included either a painful nonunion, a concomitant ipsilateral operative scapula fracture, ≥ 1 cm of displacement on X-ray, or a multiple disruption of the superior shoulder suspensory complex. All patients were followed until they were asymptomatic, displayed radiographic fracture union, and had recovered full motion with no pain. Patients and results 21 males and 5 females, mean age 36 (18–67) years, were included in the study. 18 patients had more than one indication for surgery. Of the 27 fractures, there were 13 acromion fractures and 14 coracoid fractures. 1 patient was treated for both a coracoid and an acromion fracture. Fracture patterns for the acromion included 6 acromion base fractures and 7 fractures distal to the base. Coracoid fracture patterns included 11 coracoid base fractures and 3 fractures distal to the base. Mean follow-up was 11 (2–42) months. All fractures united and all patients had recovered full motion with no pain at the time of final follow-up. 3 patients underwent removal of hardware due to irritation from hardware components that were too prominent. There were no other complications. Interpretation While most acromion and coracoid fractures can be treated nonoperatively with satisfactory results, operative management may be indicated for displaced fractures and double lesions of the superior shoulder suspensory complex. PMID:19857183

  7. Complex association between body weight and fracture risk in postmenopausal women.

    PubMed

    Mpalaris, V; Anagnostis, P; Goulis, D G; Iakovou, I

    2015-03-01

    Osteoporosis is a common disease, characterized by low bone mass with micro-architectural disruption and skeletal fragility, resulting in an increased risk of fracture. A substantial number of studies has examined the possible relationship between body weight, bone mineral density and fracture risk in post-menopausal women, with the majority of them concluding that low body weight correlates with increased risk of fracture, especially hip fracture. Controversies about the potential protective effect of obesity on osteoporosis and consequent fracture risk still exist. Several recent studies question the concept that obesity exerts a protective effect against fractures, suggesting that it stands as a risk factor for fractures at specific skeletal sites, such as upper arm. The association between body weight and fracture risk is complex, differs across skeletal sites and body mass index, and is modified by the interaction between body weight and bone mineral density. Some potential explanations that link obesity with increased fracture risk may be the pattern of falls and impaired mobility in obese individuals, comorbidities, such as asthma, diabetes and early menopause, as well as, increased parathyroid hormone and reduced 25-hydroxy-vitamin D concentrations. © 2015 World Obesity.

  8. Pore-scale modeling of hydromechanical coupled mechanics in hydrofracturing process

    NASA Astrophysics Data System (ADS)

    Chen, Zhiqiang; Wang, Moran

    2017-05-01

    Hydrofracturing is an important technique in petroleum industry to stimulate well production. Yet the mechanism of induced fracture growth is still not fully understood, which results in some unsatisfactory wells even with hydrofracturing treatments. In this work we establish a more accurate numerical framework for hydromechanical coupling, where the solid deformation and fracturing are modeled by discrete element method and the fluid flow is simulated directly by lattice Boltzmann method at pore scale. After validations, hydrofracturing is simulated with consideration on the strength heterogeneity effects on fracture geometry and microfailure mechanism. A modified topological index is proposed to quantify the complexity of fracture geometry. The results show that strength heterogeneity has a significant influence on hydrofracturing. In heterogeneous samples, the fracturing behavior is crack nucleation around the tip of fracture and connection of it to the main fracture, which is usually accompanied by shear failure. However, in homogeneous ones the fracture growth is achieved by the continuous expansion of the crack, where the tensile failure often dominates. It is the fracturing behavior that makes the fracture geometry in heterogeneous samples much more complex than that in homogeneous ones. In addition, higher pore pressure leads to more shear failure events for both heterogeneous and homogeneous samples.

  9. Experimental analysis of multiple factors on hydraulic fracturing in coalbed methane reservoirs

    PubMed Central

    Ma, Geng; Liu, Xiao; Tao, Yunqi; Feng, Dan; Li, Rui

    2018-01-01

    Hydraulic fracturing can improve the permeability of coalbed methane (CBM) reservoirs effectively, which is of great significance to the commercial production of CBM. However, the efficiency of hydraulic fracturing is affected by multiple factors. The mechanism of fracture initiation, morphology and propagation in CBM reservoirs is not clear and need to be further explored. Hydraulic fracturing experiment is an accurate tool to explore these mechanisms. The quantity of experimental coal rock is large and processing method is complex, so specimen made of similar materials was applied to replace coal rock. The true triaxial hydraulic fracturing experimental apparatus, 3D scanning device for coal rock section were applied to carry out hydraulic fracturing experiment. The results show that the initiation pressure is inversely proportional to the horizontal stress difference (Δσ) and positively related to fracturing fluid injection rate. When vertical stress (σv) is constant, the initiation pressure and fracture width decrease with the increasing of Δσ. Natural fractures can be connected by main fracture when propagates perpendicular to the direction of minimum horizontal stress (σh), then secondary fractures and fracture network form in CBM reservoirs. When two stresses of crustal stress are close and far different from the third one, the fracture morphology and propagation become complex. Influenced by perforations and filtration of fracturing fluid in specimen, fracturing fluid flows to downward easily after comparing horizontal well fracturing with vertical well fracturing. Fracture width increases with the decreasing of elastic modulus, the intensity of fracture is positively related with the elastic modulus of coal rock. The research results can provide theoretical basis and technical support for the efficient development of CBM. PMID:29621295

  10. Experimental analysis of multiple factors on hydraulic fracturing in coalbed methane reservoirs.

    PubMed

    Zhang, Fan; Ma, Geng; Liu, Xiao; Tao, Yunqi; Feng, Dan; Li, Rui

    2018-01-01

    Hydraulic fracturing can improve the permeability of coalbed methane (CBM) reservoirs effectively, which is of great significance to the commercial production of CBM. However, the efficiency of hydraulic fracturing is affected by multiple factors. The mechanism of fracture initiation, morphology and propagation in CBM reservoirs is not clear and need to be further explored. Hydraulic fracturing experiment is an accurate tool to explore these mechanisms. The quantity of experimental coal rock is large and processing method is complex, so specimen made of similar materials was applied to replace coal rock. The true triaxial hydraulic fracturing experimental apparatus, 3D scanning device for coal rock section were applied to carry out hydraulic fracturing experiment. The results show that the initiation pressure is inversely proportional to the horizontal stress difference (Δσ) and positively related to fracturing fluid injection rate. When vertical stress (σv) is constant, the initiation pressure and fracture width decrease with the increasing of Δσ. Natural fractures can be connected by main fracture when propagates perpendicular to the direction of minimum horizontal stress (σh), then secondary fractures and fracture network form in CBM reservoirs. When two stresses of crustal stress are close and far different from the third one, the fracture morphology and propagation become complex. Influenced by perforations and filtration of fracturing fluid in specimen, fracturing fluid flows to downward easily after comparing horizontal well fracturing with vertical well fracturing. Fracture width increases with the decreasing of elastic modulus, the intensity of fracture is positively related with the elastic modulus of coal rock. The research results can provide theoretical basis and technical support for the efficient development of CBM.

  11. Identification of fracture zones and its application in automatic bone fracture reduction.

    PubMed

    Paulano-Godino, Félix; Jiménez-Delgado, Juan J

    2017-04-01

    The preoperative planning of bone fractures using information from CT scans increases the probability of obtaining satisfactory results, since specialists are provided with additional information before surgery. The reduction of complex bone fractures requires solving a 3D puzzle in order to place each fragment into its correct position. Computer-assisted solutions may aid in this process by identifying the number of fragments and their location, by calculating the fracture zones or even by computing the correct position of each fragment. The main goal of this paper is the development of an automatic method to calculate contact zones between fragments and thus to ease the computation of bone fracture reduction. In this paper, an automatic method to calculate the contact zone between two bone fragments is presented. In a previous step, bone fragments are segmented and labelled from CT images and a point cloud is generated for each bone fragment. The calculated contact zones enable the automatic reduction of complex fractures. To that end, an automatic method to match bone fragments in complex fractures is also presented. The proposed method has been successfully applied in the calculation of the contact zone of 4 different bones from the ankle area. The calculated fracture zones enabled the reduction of all the tested cases using the presented matching algorithm. The performed tests show that the reduction of these fractures using the proposed methods leaded to a small overlapping between fragments. The presented method makes the application of puzzle-solving strategies easier, since it does not obtain the entire fracture zone but the contact area between each pair of fragments. Therefore, it is not necessary to find correspondences between fracture zones and fragments may be aligned two by two. The developed algorithms have been successfully applied in different fracture cases in the ankle area. The small overlapping error obtained in the performed tests demonstrates the absence of visual overlapping in the figures. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Minimally invasive treatment for pubic ramus fractures combined with a sacroiliac joint complex injury.

    PubMed

    Yu, Xiaowei; Tang, Mingjie; Zhou, Zubin; Peng, Xiaochun; Wu, Tianyi; Sun, Yuqiang

    2013-08-01

    Fractures of the pubic rami due to low energy trauma are common in the elderly, with an incidence of 26 per 100,000 people per year in those aged more than 60 years. The purpose of this study was to evaluate the clinical application of this minimally invasive technique in patients with pubic ramus fractures combined with a sacroiliac joint complex injury, including its feasibility, merits, and limitations. Fifteen patients with pubic ramus fractures combined with sacroiliac joint injury were treated with the minimally invasive technique from June 2008 until April 2012. The quality of fracture reduction was evaluated according to the Matta standard. Fourteen cases were excellent (93.3 %), and one case was good (6.7 %). The fracture lines were healed 12 weeks after the surgery. The 15 patients had follow-up visits between four to 50 months (mean, 22.47 months). All patients returned to their pre-injury jobs and lifestyles. One patient suffered a deep vein thrombosis during the peri-operative period. A filter was placed in the patient before the surgery and was removed six weeks later. There was no thrombus found at the follow-up visits of this patient. The minimally invasive technique in patients with pubic ramus fractures combined with a sacroiliac joint complex injury provided satisfactory efficacy.

  13. 3D Numerical Modeling of the Propagation of Hydraulic Fracture at Its Intersection with Natural (Pre-existing) Fracture

    NASA Astrophysics Data System (ADS)

    Dehghan, Ali Naghi; Goshtasbi, Kamran; Ahangari, Kaveh; Jin, Yan; Bahmani, Aram

    2017-02-01

    A variety of 3D numerical models were developed based on hydraulic fracture experiments to simulate the propagation of hydraulic fracture at its intersection with natural (pre-existing) fracture. Since the interaction between hydraulic and pre-existing fractures is a key condition that causes complex fracture patterns, the extended finite element method was employed in ABAQUS software to simulate the problem. The propagation of hydraulic fracture in a fractured medium was modeled in two horizontal differential stresses (Δ σ) of 5e6 and 10e6 Pa considering different strike and dip angles of pre-existing fracture. The rate of energy release was calculated in the directions of hydraulic and pre-existing fractures (G_{{frac}} /G_{{rock}}) at their intersection point to determine the fracture behavior. Opening and crossing were two dominant fracture behaviors during the hydraulic and pre-existing fracture interaction at low and high differential stress conditions, respectively. The results of numerical studies were compared with those of experimental models, showing a good agreement between the two to validate the accuracy of the models. Besides the horizontal differential stress, strike and dip angles of the natural (pre-existing) fracture, the key finding of this research was the significant effect of the energy release rate on the propagation behavior of the hydraulic fracture. This effect was more prominent under the influence of strike and dip angles, as well as differential stress. The obtained results can be used to predict and interpret the generation of complex hydraulic fracture patterns in field conditions.

  14. Complex tibial fractures are associated with lower social classes and predict early exit from employment and worse patient-reported QOL: a prospective observational study of 46 complex tibial fractures treated with a ring fixator.

    PubMed

    Elsoe, Rasmus; Larsen, Peter; Petruskevicius, Juozas; Kold, Søren

    2018-04-01

    The long-term outcomes following complex fractures of the tibia are reported to carry a risk of knee pain, malalignment, articular injury and post-traumatic osteoarthritis. The main objective of this study was to account for the patient-reported quality of life (QOL) 12 months after ring fixator removal in patients with a complex tibial fracture. Secondary objectives included a review of the socio-economic characteristics of the patient group and the rate of return to work in the study period. A prospective follow-up study was conducted of 60 patients with complex fractures of the tibia treated with ring external fixation. Patient-reported outcomes, radiological outcomes and socio-economic status including employment status of the patients were obtained 12 months after frame removal. Forty-six patients completed the assessment 12 months after frame removal (77%). The mean age of the patient at the time of fracture was 54.6 years (range 31-86). There were 19 males and 27 females. At 12 months after frame removal, the mean EQ5D-5L index was 0.66 (CI 0.60-0.72). The mean EQ5D-5L VAS was 69 (CI 61-76). When this was compared to the established reference population from Denmark, the study population showed a significantly worse EQ5D-5L index. The majority of patients (87%) were in the lower social classes suggesting a higher degree of social deprivation in the study population. Twenty-seven per cent of patients who were employed prior to injury had returned to employment at approximately 19 months following fracture. The onset of post-traumatic osteoarthritis was present in the knee joint in 29% of patients following a proximal intra-articular fracture, whereas osteoarthritis was present at the ankle joint in 35% of patients following a distal intra-articular fracture 12 months after frame removal. This study indicates that at 12 months after frame removal there are poorer patient-reported QOL as when compared to reference populations. Furthermore, this study suggests that complex tibial fractures are associated with lower social classes and that only 27% of patients in this sample, who prior to injury were employed, had returned to employment at approximately 19 months after the injury.

  15. Prosthetic replacement for proximal humeral fractures.

    PubMed

    Kontakis, George; Tosounidis, Theodoros; Galanakis, Ioannis; Megas, Panagiotis

    2008-12-01

    The ideal management of complex proximal humeral fractures continues to be debatable. Evolution of proximal humeral fracture management, during the past decade, led to the implementation of many innovations in surgical treatment. Even though the pendulum of treatment seems to swing towards new trends such as locked plating, hemiarthroplasty remains a valid and reliable option that serves the patient's needs well. Hemiarthroplasty is indicated for complex proximal humeral fractures in elderly patients with poor bone stock and when internal fixation is difficult or unreliable. Hemiarthroplasty provides a better result when it is performed early post-injury. Stem height, retroversion and tuberosity positioning are technical aspects of utmost importance. Additionally reverse total shoulder arthroplasty is an alternative new modality that can be used as a primary solution in selected patients with proximal humeral fracture treatment. Failed hemiarthroplasty and fracture sequelae can be successfully managed with reverse total shoulder arthroplasty. Individual decision-making and tailored treatment that takes into consideration the personality of the fracture and the patient's characteristics should be used.

  16. Managing the Pediatric Facial Fracture

    PubMed Central

    Cole, Patrick; Kaufman, Yoav; Hollier, Larry H.

    2009-01-01

    Facial fracture management is often complex and demanding, particularly within the pediatric population. Although facial fractures in this group are uncommon relative to their incidence in adult counterparts, a thorough understanding of issues relevant to pediatric facial fracture management is critical to optimal long-term success. Here, we discuss several issues germane to pediatric facial fractures and review significant factors in their evaluation, diagnosis, and management. PMID:22110800

  17. Brittle fracture phase-field modeling of a short-rod specimen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Escobar, Ivana; Tupek, Michael R.; Bishop, Joseph E.

    2015-09-01

    Predictive simulation capabilities for modeling fracture evolution provide further insight into quantities of interest in comparison to experimental testing. Based on the variational approach to fracture, the advent of phase-field modeling achieves the goal to robustly model fracture for brittle materials and captures complex crack topologies in three dimensions.

  18. Management of distal humeral coronal shear fractures

    PubMed Central

    Yari, Shahram S; Bowers, Nathan L; Craig, Miguel A; Reichel, Lee M

    2015-01-01

    Coronal shear fractures of the distal humerus are rare, complex fractures that can be technically challenging to manage. They usually result from a low-energy fall and direct compression of the distal humerus by the radial head in a hyper-extended or semi-flexed elbow or from spontaneous reduction of a posterolateral subluxation or dislocation. Due to the small number of soft tissue attachments at this site, almost all of these fractures are displaced. The incidence of distal humeral coronal shear fractures is higher among women because of the higher rate of osteoporosis in women and the difference in carrying angle between men and women. Distal humeral coronal shear fractures may occur in isolation, may be part of a complex elbow injury, or may be associated with injuries proximal or distal to the elbow. An associated lateral collateral ligament injury is seen in up to 40% and an associated radial head fracture is seen in up to 30% of these fractures. Given the complex nature of distal humeral coronal shear fractures, there is preference for operative management. Operative fixation leads to stable anatomic reduction, restores articular congruity, and allows initiation of early range-of-motion movements in the majority of cases. Several surgical exposure and fixation techniques are available to reconstruct the articular surface following distal humeral coronal shear fractures. The lateral extensile approach and fixation with countersunk headless compression screws placed in an anterior-to-posterior fashion are commonly used. We have found a two-incision approach (direct anterior and lateral) that results in less soft tissue dissection and better outcomes than the lateral extensile approach in our experience. Stiffness, pain, articular incongruity, arthritis, and ulnohumeral instability may result if reduction is non-anatomic or if fixation fails. PMID:25984515

  19. Complex proximal humeral fractures: a prospective study of 22 cases treated using the "Bilboquet" device.

    PubMed

    Doursounian, L; Kilinc, A; Cherrier, B; Nourissat, G

    2011-02-01

    Despite recent improvements in surgical devices, complex proximal humerus fractures internal fixation still encounters frequent mechanical failures. The aim of this study was to confirm that the Bilboquet device (a design mimicking the cup-and-ball game) helps solving mechanical difficulties associated with these fractures internal fixation and to present a simplified version of the original surgical procedure. This non-randomised prospective study included 22 fractures in 22 patients, mean age: 70 years. According to the Neer classification there were three-part fractures in seven cases and four-part fractures in 15 cases. Fractures were all reduced and treated by internal fixation in a simplified surgical procedure using the Bilboquet device. Mean postoperative follow-up was 34 months. The mean Constant score was 66 and the weighted Constant score was 86. Mean active forward elevation was 108° and mean active external rotation was 28°. No per- or postoperative complications occurred. Initial reduction of the tuberosity was incomplete in four cases. Union was obtained in all fractures. There was no secondary tilting of the head, and no migration or pseudarthrosis of the tuberosities. Five patients developed postoperative avascular necrosis of the humeral head. The Bilboquet staple component provides a supporting platform for the entire humeral head area. This peripheral stabilization associated with tension band wiring explains the lack of secondary displacement in these cases. Although the Bilboquet device provides a solution to the mechanical problems of complex fractures of the proximal humerus, it does not solve the problem of secondary avascular necrosis of the humeral head, which occurred in 23% of the patients in this series and in 33% of patients in the four-part fractures subgroup. IV (non-randomised prospective study). Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  20. Modeling the fracture of ice sheets on parallel computers.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Waisman, Haim; Bell, Robin; Keyes, David

    2010-03-01

    The objective of this project is to investigate the complex fracture of ice and understand its role within larger ice sheet simulations and global climate change. At the present time, ice fracture is not explicitly considered within ice sheet models due in part to large computational costs associated with the accurate modeling of this complex phenomena. However, fracture not only plays an extremely important role in regional behavior but also influences ice dynamics over much larger zones in ways that are currently not well understood. Dramatic illustrations of fracture-induced phenomena most notably include the recent collapse of ice shelves inmore » Antarctica (e.g. partial collapse of the Wilkins shelf in March of 2008 and the diminishing extent of the Larsen B shelf from 1998 to 2002). Other fracture examples include ice calving (fracture of icebergs) which is presently approximated in simplistic ways within ice sheet models, and the draining of supraglacial lakes through a complex network of cracks, a so called ice sheet plumbing system, that is believed to cause accelerated ice sheet flows due essentially to lubrication of the contact surface with the ground. These dramatic changes are emblematic of the ongoing change in the Earth's polar regions and highlight the important role of fracturing ice. To model ice fracture, a simulation capability will be designed centered around extended finite elements and solved by specialized multigrid methods on parallel computers. In addition, appropriate dynamic load balancing techniques will be employed to ensure an approximate equal amount of work for each processor.« less

  1. Edge Fracture in Complex Fluids.

    PubMed

    Hemingway, Ewan J; Kusumaatmaja, Halim; Fielding, Suzanne M

    2017-07-14

    We study theoretically the edge fracture instability in sheared complex fluids, by means of linear stability analysis and direct nonlinear simulations. We derive an exact analytical expression for the onset of edge fracture in terms of the shear-rate derivative of the fluid's second normal stress difference, the shear-rate derivative of the shear stress, the jump in shear stress across the interface between the fluid and the outside medium (usually air), the surface tension of that interface, and the rheometer gap size. We provide a full mechanistic understanding of the edge fracture instability, carefully validated against our simulations. These findings, which are robust with respect to choice of rheological constitutive model, also suggest a possible route to mitigating edge fracture, potentially allowing experimentalists to achieve and accurately measure flows stronger than hitherto possible.

  2. The use of circular external fixators in the management of lower limb trauma in Dublin: a single surgeon's 20-year experience.

    PubMed

    O'Neill, B J; Fox, C M; Molloy, A P; O'hEireamhoin, S; Moore, D P

    2016-02-01

    It has been estimated that approximately 520,000 injury presentations are made to Irish accident and emergency departments each year. Fractures account for 20 % of these injuries. Circular external fixators (frames) have been shown to be a safe and effective method of treatment for long bone fractures where internal fixation is impossible or in-advisable. We present the outcomes of all frames applied at our institution for stabilisation of acute fractures over a 20-year period. We retrospectively reviewed a prospectively compiled database of all frames applied in our institution and identified all frames which were applied for acute lower limb trauma. We identified 68 fractures in 63 patients. There were 11 femoral fractures and 57 tibial fractures. All fractures were classified using the AO Classification system, and most fractures were Type C fractures. We used an Ilizarov frame for 53 fractures and a Taylor Spatial Frame for 15 fractures. The mean time in frame was 365 days for a femoral fracture and 230 days for a tibial fracture. There were five tibial non-unions giving an overall union rate of 93 %. Factors associated with non-union included high-energy trauma and cigarette smoking. The vast majority of lower limb fractures can be treated using 'conventional' methods. Complex fractures which are not amenable to open reduction and internal fixation or cast immobilisation can be treated in a frame with excellent results. The paucity of published reports regarding the use of frames for complex trauma reflects the under-utilisation of the technique.

  3. Dry Volume Fracturing Simulation of Shale Gas Reservoir

    NASA Astrophysics Data System (ADS)

    Xu, Guixi; Wang, Shuzhong; Luo, Xiangrong; Jing, Zefeng

    2017-11-01

    Application of CO2 dry fracturing technology to shale gas reservoir development in China has advantages of no water consumption, little reservoir damage and promoting CH4 desorption. This paper uses Meyer simulation to study complex fracture network extension and the distribution characteristics of shale gas reservoirs in the CO2 dry volume fracturing process. The simulation results prove the validity of the modified CO2 dry fracturing fluid used in shale volume fracturing and provides a theoretical basis for the following study on interval optimization of the shale reservoir dry volume fracturing.

  4. An integrated profile of natural fractures in gas-bearing shale complex (Pomerania, Poland): based on structural profiling of oriented core and borehole logging data.

    NASA Astrophysics Data System (ADS)

    Bobek, Kinga; Jarosiński, Marek; Stadtmuller, Marek; Pachytel, Radomir; Lis-Śledziona, Anita

    2016-04-01

    Natural fractures in gas-bearing shales has significant impact on reservoir stimulation and increase of exploitation. Density of natural fractures and their orientation in respect to the maximum horizontal stress are crucial for propagation of technological hydraulic fractures. Having access to continuous borehole core profile and modern geophysical logging from several wells in the Pomeranian part of the Early Paleozoic Baltic Basin (Poland) we were able to compare the consistency of structural interpretation of several data sets. Although, final aim of our research is to optimize the method of fracture network reconstruction on a reservoir scale, at a recent stage we were focused on quantitative characterization of tectonic structures in a direct vicinity of boreholes. The data we have, cover several hundred meters long profiles of boreholes from the Ordovician and Silurian shale complexes. Combining different sets of data we broaden the scale of observation from borehole core (5 cm radius), through XRMI scan of a borehole wall (10 cm radius), up to penetration of a signal of an acoustic dipole logging (several tens of cm range). At the borehole core we examined the natural tectonic structures and mechanically significant features, like: mineral veins, fractured veins, bare fractures, slickensides, fault zones, stylolites, bedding plane and mechanically contrasting layers. We have also noticed drilling-induced features like centerline fractures and core disking, controlled by a recent tectonic stress. We have measured the orientation of fractures, their size, aperture and spacing and also describe the character of veins and tried to determine the stress regime responsible for fault slippage and fracture propagation. Wide range of analyzed features allowed us to discriminate fracture sets and reconstruct tectonic evolution of the complex. The most typical for analyzed shale complexes are steep and vertical strata-bound fractures that create an orthogonal joint system, which is locally disturbed by small-scale faults and fractures, associated with them. For regular joints, observed on borehole core, we have calculated variation of mean height and area and volume of mineralization for veins. Fracture density variation reveals good correlation with lithological shale formations which are comparable with Consistent Mechanical Units differentiated based on detailed lithological profiling and geophysical data (see Pachytel et al., this issue).We have also proposed a new method of a rose diagram construction presenting strike of fractures taking into account their size and angular error bar in strike determination. Each fracture was weighted with its length or aperture and an angular error was included by blurring the less credible records. This allowed for more precise adjustment of fracture sets direction in comparison to conventional diagrams without weighting procedure. Recently, we are processing acoustic dipole logs for anisotropy analyses aiming in comparison with density of fracture sets. Our study, which is conducted in the frame of ShaleMech Project (within Blue Gas Program) is in progress, thus the presented results should be considered as preliminary.

  5. Managing Complications of Calcaneus Fractures.

    PubMed

    Clare, Michael P; Crawford, William S

    2017-03-01

    Calcaneus fractures remain among the most complicated fractures for orthopedic surgeons to manage because of the complexity of various fracture patterns, the limited surrounding soft tissue envelope, and the prolonged rehabilitation issues impacting function after successful treatment. Despite this, appropriate management of complications associated with calcaneus fractures is critical for the complete care of this injury, whether treated operatively or nonoperatively. The authors present the common complications encountered with fractures of the calcaneus and management thereof. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Changing pattern and etiology of maxillofacial fractures during the civil uprising in Western Libya

    PubMed Central

    Elarabi, Mohammed S.

    2018-01-01

    Background The purpose of the present study was to evaluate changing pattern in characteristics of maxillofacial fractures and concomitant injuries in Western Libya During revolution and to assess the association between mechanism of injury and fracture patterns. Material and Methods A retrospective review of medical records and radiographs of 187 patients treated for maxillofacial fractures from January 2010 to December 2012 was performed, there were 326 fractures in 187 patients. Results The male: female ratio was 6:1. Most fractures occurred in patients aged 11 to 40 years, and few injuries occurred in patients aged > 50 years. Most fractures occurred from motor vehicle accidents, and other most frequent causes included assault, gunshot, and fall injuries. Most maxillofacial fractures involved the mandible, zygomatic complex, or maxilla. Most mandibular fractures occurred at the parasymphysis, angle, or condyle. Associated injuries most frequently involved the head, chest, and extremities. Most patients were treated with open reduction (132 patients [71%]), and 26 patients (14%) were treated nonoperatively. There were 21 complications (11%). Conclusions In summary, motor vehicle accidents were the most frequent cause of maxillofacial fracture in western Libya, possibly because of the lack of seat belt legislation. Interpersonal violence was a less frequent cause of maxillofacial fracture, possibly because of the religious restriction on alcohol consumption. Key words:Tauma, mandible, zygomatic complex, maxilla, treatment, complications. PMID:29476683

  7. Fracture Reactivation in Chemically Reactive Rock Systems

    NASA Astrophysics Data System (ADS)

    Eichhubl, P.; Hooker, J. N.

    2013-12-01

    Reactivation of existing fractures is a fundamental process of brittle failure that controls the nucleation of earthquake ruptures, propagation and linkage of hydraulic fractures in oil and gas production, and the evolution of fault and fracture networks and thus of fluid and heat transport in the upper crust. At depths below 2-3 km, and frequently shallower, brittle processes of fracture growth, linkage, and reactivation compete with chemical processes of fracture sealing by mineral precipitation, with precipitation rates similar to fracture opening rates. We recently found rates of fracture opening in tectonically quiescent settings of 10-20 μm/m.y., rates similar to euhedral quartz precipitation under these conditions. The tendency of existing partially or completely cemented fractures to reactivate will vary depending on strain rate, mineral precipitation kinetics, strength contrast between host rock and fracture cement, stress conditions, degree of fracture infill, and fracture network geometry. Natural fractures in quartzite of the Cambrian Eriboll Formation, NW Scotland, exhibit a complex history of fracture formation and reactivation, with reactivation involving both repeated crack-seal opening-mode failure and shear failure of fractures that formed in opening mode. Fractures are partially to completely sealed with crack-seal or euhedral quartz cement or quartz cement fragmented by shear reactivation. Degree of cementation controls the tendency of fractures for later shear reactivation, to interact elastically with adjacent open fractures, and their intersection behavior. Using kinematic, dynamic, and diagenetic criteria, we determine the sequence of opening-mode fracture formation and later shear reactivation. We find that sheared fracture systems of similar orientation display spatially varying sense of slip We attribute these inconsistent directions of shear reactivation to 1) a heterogeneous stress field in this highly fractured rock unit and 2) variations in the degree of fracture cement infill in fractures of same orientation, allowing fractures to reactivate at times when adjacent, more cemented fractures remain dormant. The observed interaction of chemical and mechanical fracture growth and sealing processes in this chemically reactive and heavily deformed rock unit results in a complex fracture network geometry not generally observed in less chemically reactive, shallower crustal environments.

  8. Batman-cracks. Observations and numerical simulations

    NASA Astrophysics Data System (ADS)

    Selvadurai, A. P. S.; Busschen, A. Ten; Ernst, L. J.

    1991-05-01

    To ensure mechanical strength of fiber reinforced plastics (FRP), good adhesion between fibers and the matrix is considered to be an essential requirement. An efficient test of fiber-matrix interface characterization is the fragmentation test which provides information about the interface slip mechanism. This test consists of the longitudinal loading of a single fiber which is embedded in a matrix specimen. At critical loads the fiber experiences fragmentation. This fragmentation will terminate depending upon the shear-slip strength of the fiber-matrix adhesion, which is inversely proportional to average fragment lengths. Depending upon interface strength characteristics either bond or slip matrix fracture can occur at the onset of fiber fracture. Certain particular features of matrix fracture are observed at the locations of fiber fracture in situations where there is sufficient interface bond strength. These refer to the development of fractures with a complex surface topography. The experimental procedure involved in the fragmentation tests is discussed and the boundary element technique to examine the development of multiple matrix fractures at the fiber fracture locations is examined. The mechanics of matrix fracture is examined. When bond integrity is maintained, a fiber fracture results in a matrix fracture. The matrix fracture topography in a fragmentation test is complex; however, simplified conoidal fracture patterns can be used to investigate the crack extension phenomena. Via a mixed-mode fracture criterion, the generation of a conoidal fracture pattern in the matrix is investigated. The numerical results compare favorably with observed experimental data derived from tests conducted on fragmentation test specimens consisting of a single glass fiber which is embedded in a polyester matrix.

  9. A Numerical Study of Factors Affecting Fracture-Fluid Cleanup and Produced Gas/Water in Marcellus Shale: Part II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seales, Maxian B.; Dilmore, Robert; Ertekin, Turgay

    Horizontal wells combined with successful multistage-hydraulic-fracture treatments are currently the most-established method for effectively stimulating and enabling economic development of gas-bearing organic-rich shale formations. Fracture cleanup in the stimulated reservoir volume (SRV) is critical to stimulation effectiveness and long-term well performance. But, fluid cleanup is often hampered by formation damage, and post-fracture well performance frequently falls to less than expectations. A systematic study of the factors that hinder fracture-fluid cleanup in shale formations can help optimize fracture treatments and better quantify long-term volumes of produced water and gas. Fracture-fluid cleanup is a complex process influenced by mutliphase flow through porousmore » media (relative permeability hysteresis, capillary pressure), reservoir-rock and -fluid properties, fracture-fluid properties, proppant placement, fracture-treatment parameters, and subsequent flowback and field operations. Changing SRV and fracture conductivity as production progresses further adds to the complexity of this problem. Numerical simulation is the best and most-practical approach to investigate such a complicated blend of mechanisms, parameters, their interactions, and subsequent effect on fracture-fluid cleanup and well deliverability. Here, a 3D, two-phase, dual-porosity model was used to investigate the effect of mutliphase flow, proppant crushing, proppant diagenesis, shut-in time, reservoir-rock compaction, gas slippage, and gas desorption on fracture-fluid cleanup and well performance in Marcellus Shale. Our findings have shed light on the factors that substantially constrain efficient fracture-fluid cleanup in gas shales, and we have provided guidelines for improved fracture-treatment designs and water management.« less

  10. A Numerical Study of Factors Affecting Fracture-Fluid Cleanup and Produced Gas/Water in Marcellus Shale: Part II

    DOE PAGES

    Seales, Maxian B.; Dilmore, Robert; Ertekin, Turgay; ...

    2017-04-01

    Horizontal wells combined with successful multistage-hydraulic-fracture treatments are currently the most-established method for effectively stimulating and enabling economic development of gas-bearing organic-rich shale formations. Fracture cleanup in the stimulated reservoir volume (SRV) is critical to stimulation effectiveness and long-term well performance. But, fluid cleanup is often hampered by formation damage, and post-fracture well performance frequently falls to less than expectations. A systematic study of the factors that hinder fracture-fluid cleanup in shale formations can help optimize fracture treatments and better quantify long-term volumes of produced water and gas. Fracture-fluid cleanup is a complex process influenced by mutliphase flow through porousmore » media (relative permeability hysteresis, capillary pressure), reservoir-rock and -fluid properties, fracture-fluid properties, proppant placement, fracture-treatment parameters, and subsequent flowback and field operations. Changing SRV and fracture conductivity as production progresses further adds to the complexity of this problem. Numerical simulation is the best and most-practical approach to investigate such a complicated blend of mechanisms, parameters, their interactions, and subsequent effect on fracture-fluid cleanup and well deliverability. Here, a 3D, two-phase, dual-porosity model was used to investigate the effect of mutliphase flow, proppant crushing, proppant diagenesis, shut-in time, reservoir-rock compaction, gas slippage, and gas desorption on fracture-fluid cleanup and well performance in Marcellus Shale. Our findings have shed light on the factors that substantially constrain efficient fracture-fluid cleanup in gas shales, and we have provided guidelines for improved fracture-treatment designs and water management.« less

  11. Computed tomography image-guided surgery in complex acetabular fractures.

    PubMed

    Brown, G A; Willis, M C; Firoozbakhsh, K; Barmada, A; Tessman, C L; Montgomery, A

    2000-01-01

    Eleven complex acetabular fractures in 10 patients were treated by open reduction with internal fixation incorporating computed tomography image guided software intraoperatively. Each of the implants placed under image guidance was found to be accurate and without penetration of the pelvis or joint space. The setup time for the system was minimal. Accuracy in the range of 1 mm was found when registration was precise (eight cases) and was in the range of 3.5 mm when registration was only approximate (three cases). Added benefits included reduced intraoperative fluoroscopic time, less need for more extensive dissection, and obviation of additional surgical approaches in some cases. Compared with a series of similar fractures treated before this image guided series, the reduction in operative time was significant. For patients with complex anterior and posterior combined fractures, the average operation times with and without application of three-dimensional imaging technique were, respectively, 5 hours 15 minutes and 6 hours 14 minutes, revealing 16% less operative time for those who had surgery using image guidance. In the single column fracture group, the operation time for those with three-dimensional imaging application, was 2 hours 58 minutes and for those with traditional surgery, 3 hours 42 minutes, indicating 20% less operative time for those with imaging modality. Intraoperative computed tomography guided imagery was found to be an accurate and suitable method for use in the operative treatment of complex acetabular fractures with substantial displacement.

  12. The treatment of complex proximal humeral fractures: analysis of the results of 55 cases treated with PHILOS plate.

    PubMed

    Fattoretto, D; Borgo, A; Iacobellis, C

    2016-08-01

    Complex proximal humerus fractures are often difficult to treat. Their frequency is high, especially in the elderly, and their treatment is still controversial. The aim of this study was to analyze the clinical and radiological results achieved by patients with complex proximal humerus fractures, treated with PHILOS plate only. A cohort of 55 patients was selected. The mean age was 63.4 (range 33-89), while the mean follow-up time was 21.5 months (range 6-75). Clinical outcome was evaluated with the "Constant-Murley shoulder score." All the informations about the presence of complications were gathered, and radiological images were used to calculate the head-shaft angle. The overall mean Constant score was 61.93 ± 18.59, the Individual CS was 70 ± 20 % and the Relative CS was 83 ± 23 %. No significant differences were found between fractures Neer 3 and Neer 4 and between the surgical approaches (delta-split vs. delto-pectoral). Six patients had a fracture with dislocation, seven patients (12.7 %) had complications while in four patients a head-shaft angle beyond the normal range was found. Osteosynthesis with PHILOS plate is stable in the greater part of the cases, and it allows an earlier rehabilitation and so a good functional result, which could be compromised by a prolonged immobilization. Therefore, PHILOS plate is a good option for the treatment of complex proximal humerus fractures.

  13. An overview of geophysical technologies appropriate for characterization and monitoring at fractured-rock sites

    EPA Science Inventory

    Geophysical methods are used increasingly for characterization and monitoring at remediation sites in fractured-rock aquifers. The complex heterogeneity of fractured rock poses enormous challenges to groundwater remediation professionals, and new methods are needed to cost-effect...

  14. Deep Vadose Zone Flow and Transport Behavior at T-Tunnel Complex, Rainier Mesa, Nevada National Security Site

    NASA Astrophysics Data System (ADS)

    Parashar, R.; Reeves, D. M.

    2010-12-01

    Rainier Mesa, a tuffaceous plateau on the Nevada National Security Site, has been the location of numerous subsurface nuclear tests conducted in a series of tunnel complexes located approximately 450 m below the top of the mesa and 500 m above the regional groundwater flow system. The tunnels were constructed near the middle of an 800 m Tertiary sequence of faulted, low-permeability welded and non-welded bedded, vitric, and zeolitized tuff units. Water levels from wells in the vicinity of the T-tunnel complex indicate the presence of a perched saturation zone located approximately 100 m above the T-tunnel complex. This upper zone of saturation extends downward through most of the Tertiary sequence. The groundwater table is located at an elevation of 1300 m within a thrust sheet of Paleozoic carbonates, corresponding to the lower carbonate aquifer hydrostratigraphic unit (LCA3). The LCA3 is considered to be hydraulically connected to the Death Valley regional flow system. The objective of this project is to simulate complex downward patterns of fluid flow and radionuclide transport from the T-tunnel complex through the matrix and fault networks of the Tertiary tuff units to the water table. We developed an improved fracture characterization and mapping methodology consisting of displacement-length scaling relationships, simulation of realistic fault networks based on site-specific data, and the development of novel fracture network upscaling techniques that preserves fracture network flow and transport properties on coarse continuum grid. Development of upscaling method for fracture continua is based on the concepts of discrete fracture network modeling approach which performs better at honoring network connectivity and anisotropy of sparse networks in comparison to other established methods such as a tensor approach. Extensive flow simulations in the dual-continuum framework demonstrate that the characteristics of fault networks strongly influences the saturation profile and formation of perched zones, although they may not conduct a large amount of flow when compared to the matrix continua. The simulated results are found to be very sensitive to distribution of fracture aperture, density of the network, and spatial pattern of fracture clustering. The faults provide rapid pathways for radionuclide transport and the conceptual modeling of diffusional mass transfer between matrix and fracture continua plays a vital role in prediction of the overall behavior of the breakthrough curve.

  15. Three-dimensional computer simulation of radiostereometric analysis (RSA) in distal radius fractures.

    PubMed

    Madanat, Rami; Moritz, Niko; Aro, Hannu T

    2007-01-01

    Physical phantom models have conventionally been used to determine the accuracy and precision of radiostereometric analysis (RSA) in various orthopaedic applications. Using a phantom model of a fracture of the distal radius it has previously been shown that RSA is a highly accurate and precise method for measuring both translation and rotation in three-dimensions (3-D). The main shortcoming of a physical phantom model is its inability to mimic complex 3-D motion. The goal of this study was to create a realistic computer model for preoperative planning of RSA studies and to test the accuracy of RSA in measuring complex movements in fractures of the distal radius using this new model. The 3-D computer model was created from a set of tomographic scans. The simulation of the radiographic imaging was performed using ray-tracing software (POV-Ray). RSA measurements were performed according to standard protocol. Using a two-part fracture model (AO/ASIF type A2), it was found that for simple movements in one axis, translations in the range of 25microm-2mm could be measured with an accuracy of +/-2microm. Rotations ranging from 16 degrees to 2 degrees could be measured with an accuracy of +/-0.015 degrees . Using a three-part fracture model the corresponding values of accuracy were found to be +/-4microm and +/-0.031 degrees for translation and rotation, respectively. For complex 3-D motion in a three-part fracture model (AO/ASIF type C1) the accuracy was +/-6microm for translation and +/-0.120 degrees for rotation. The use of 3-D computer modelling can provide a method for preoperative planning of RSA studies in complex fractures of the distal radius and in other clinical situations in which the RSA method is applicable.

  16. Tectonic context of the penetrative fracture system origin in the Early Paleozoic shale complex (Baltic Basin, Poland/Sweden).

    NASA Astrophysics Data System (ADS)

    Jarosiński, Marek; Gluszynski, Andrzej; Bobek, Kinga; Dyrka, Ireneusz

    2017-04-01

    Characterization of natural fracture and fault pattern play significant role for reservoir stimulation design and evaluation of its results. Having structural observations limited to immediate borehole surrounding it is a common need to build up a fracture model of reservoir in a range of stimulation reservoir volume or even beyond. To do this we need both a 3D seismic model and a consistent concept of the regional tectonic evolution. We present the result of integrated tectonic study in several deep boreholes target the Lower Paleozoic shale complex of Baltic Basin (BB), combined with analysis of 3D seismic survey and outcrop screening in Scania (Swedish part of the BB). During deposition of shale complex in the Ordovician and Silurian the research area was located 200-300 km away from the continental margin of Baltica involved in the Caledonian collision with the Eastern Avalonia. This distance allowed the shale complex to avoid significant tectonic deformation. Regional seismic cross section reveals the general pattern of the BB infill characteristic for the foreland basin underwent post-collisional isostatic rebound. Due to stress changes in collisional context the shale complex was cross-cut by steep, mostly inverse faults trending NW-SE and NE-SW. The fault zones oriented NW-SE are associated with an array of en echelon faults characteristic for strike-slip displacement. In our interpretation, these faults of Silurian (Wenlock) age create pattern of the regional pop-up structure, which is simultaneously involved in the plate flexure extension. Seismic attributes (e.g. curvature or ant tracking) highlight lineaments which mostly mimic the faults orientation. However, attributes show also some artefacts that come from regular array of seismic sources and receivers, which mimic the orthogonal joint system. Structural observations on borehole core lead us to conclusion that regular, orthogonal fracture system developed after maximum burial of the complex, triggered by mechanism of natural hydraulic fracturing due to hydrocarbon generation. These fractures create veins filled with calcite that growth was controlled by mechanical layering and the TOC content of the shale complex. The main joint fracture pattern is stable across at least 300 hundred kilometers, from the Polish to Swedish portion of Baltic Basin. Therefore a major tectonic event is expected to govern its origin. The Late Carboniferous thin-skinned compression exerted at the edge of the East European Craton, is preferred tectonic fracture triggering factor. This age of jointing is confirmed by the strike of principal joint set characteristic for Variscan compression. In addition, principal joint system is sensitive (=younger) to a presence of the Caledonian-age faults in Pomerania but insensitive (=older) to the Mesozoic faults in Scania. Above genetic considerations should be taken into account while building the self-consistent discrete fracture network of faults and fractures for the purpose of shale reservoir stimulation.

  17. [APPLICATION OF BUTTERFLY SHAPED LOCKING COMPRESSION PLATE IN COMPLEX DISTAL RADIUS FRACTURES].

    PubMed

    Jiang, Zongyuan; Ma, Tao; Xia, Jiang; Hu, Caizhi; Xu, Lei

    2014-06-01

    To investigate the effectiveness of butterfly shaped locking compression plate for the treatment of complex distal radius fractures. Between June 2011 and January 2013, 20 cases of complex distal radius fractures were treated with butterfly shaped locking compression plate fixation. There were 11 males and 9 females with an average age of 54 years (range, 25-75 years). Injury was caused by falling in 10 cases, by traffic accident in 7 cases, and by falling from height in 3 cases. All of fractures were closed. According to AO classification system, there were 8 cases of type C1, 8 cases of type C2, and 4 cases of type C3. Of them, 9 cases had radial styloid process fracture, 4 cases had sigmoid notch fracture, and 7 cases had both radial styloid process fracture and sigmoid notch fracture. The mean interval between injury and operation was 5.2 days (range, 3-15 days). All incisions healed by first intention; no complications of infection and necrosis occurred. All cases were followed up 14 months on average (range, 10-22 months). All factures healed after 9.3 weeks on average (range, 6-11 weeks). No complications such as displacement of fracture, joint surface subsidence, shortening of the radius, and carpal tunnel syndrome were found during follow-up. At last follow-up, the mean palmar tilt angle was 10.2° (range, 7-15°), and the mean ulnar deviation angle was 21.8° (range, 17-24°). The mean range of motion of the wrist was 45.3° (range, 35-68°) in dorsal extension, 53.5° (range, 40-78°) in palmar flexion, 19.8° (range, 12-27°) in radial inclination, 26.6° (range, 18-31°) in ulnar inclination, 70.2° (range, 45-90°) in pronation, and 68.4° (range, 25-88°) in supination. According to the Dienst scoring system, the results were excellent in 8 cases, good in 10 cases, and fair in 2 cases, and the excellent and good rate was 90%. Treatment of complex distal radius fractures with butterfly shaped locking compression plate can reconstruct normal anatomic structures, especially for radial styloid process and sigmoid notch fractures, and it can get good functional recovery of the wrist and the distal radioulnar joint.

  18. The Convergence of Fracture Repair and Stem Cells: Interplay of Genes, Aging, Environmental Factors and Disease

    PubMed Central

    Hadjiargyrou, Michael; O’Keefe, Regis J

    2015-01-01

    The complexity of fracture repair makes it an ideal process for studying the interplay between the molecular, cellular, tissue, and organ level events involved in tissue regeneration. Additionally, as fracture repair recapitulates many of the processes that occur during embryonic development, investigations of fracture repair provide insights regarding skeletal embryogenesis. Specifically, inflammation, signaling, gene expression, cellular proliferation and differentiation, osteogenesis, chondrogenesis, angiogenesis, and remodeling represent the complex array of interdependent biological events that occur during fracture repair. Here we review studies of bone regeneration in genetically modified mouse models, during aging, following environmental exposure, and in the setting of disease that provide insights regarding the role of multipotent cells and their regulation during fracture repair. Complementary animal models and ongoing scientific discoveries define an increasing number of molecular and cellular targets to reduce the morbidity and complications associated with fracture repair. Last, some new and exciting areas of stem cell research such as the contribution of mitochondria function, limb regeneration signaling, and microRNA (miRNA) posttranscriptional regulation are all likely to further contribute to our understanding of fracture repair as an active branch of regenerative medicine. PMID:25264148

  19. Prediction of forming limit in hydro-mechanical deep drawing of steel sheets using ductile fracture criterion

    NASA Astrophysics Data System (ADS)

    Oh, S.-T.; Chang, H.-J.; Oh, K. H.; Han, H. N.

    2006-04-01

    It has been observed that the forming limit curve at fracture (FLCF) of steel sheets, with a relatively higher ductility limit have linear shapes, similar to those of a bulk forming process. In contrast, the FLCF of sheets with a relatively lower ductility limit have rather complex shapes approaching the forming limit curve at neck (FLCN) towards the equi-biaxial strain paths. In this study, the FLCFs of steel sheets were measured and compared with the fracture strains predicted from specific ductile fracture criteria, including a criterion suggested by the authors, which can accurately describe FLCFs with both linear and complex shapes. To predict the forming limit for hydro-mechanical deep drawing of steel sheets, the ductile fracture criteria were integrated into a finite element simulation. The simulation, results based on the criterion suggested by authors accurately predicted the experimetal, fracture limits of steel sheets for the hydro-mechanical deep drawing process.

  20. Conversion of external fixation to open reduction and internal fixation for complex distal radius fractures.

    PubMed

    Natoli, R M; Baer, M R; Bednar, M S

    2016-05-01

    Distal radius fractures are common injuries treated in a multitude of ways. One treatment paradigm not extensively studied is initial treatment by external fixation (EF) followed by conversion to open reduction internal fixation (ORIF). Such a paradigm may be beneficial in damage control situations, when there is extensive soft tissue injury, or when appropriate personnel/hospital resources are not available for immediate internal fixation. There is no increased risk of infection when converting EF to ORIF in the treatment of complex distal radius fractures when conversion occurs early or if EF pin sites are overlapped by the definitive fixation. Using an IRB approved protocol, medical records over nine years were queried to identify patients with distal radius fractures that had undergone initial EF and were later converted to ORIF. Charts were reviewed for demographic data, injury characteristics, operative details, time to conversion from EF to ORIF, assessment of whether the EF pin sites overlapped the definitive fixation, presence of infection after ORIF, complications, and occupational therapy measurements of range of motion and strength. In total, 16 patients were identified, only one of which developed an infection following conversion to ORIF. Fisher's exact testing showed that infection did not depend on open fracture, time to conversion of one week or less, presence of EF pin sites overlapping definitive fixation, fracture classification, high energy mechanism of injury, or concomitant injury to the DRUJ. Planned staged conversion from EF to ORIF for complex distal radius fractures does not appear to result in an increased rate of infection if conversion occurs early or if the EF pin sites are overlapped by definitive fixation. This treatment paradigm may be reasonable for treating complex distal radius fractures in damage control situations, when there is extensive soft tissue injury, or when appropriate personnel/hospital resources are not available for immediate internal fixation. IV, retrospective case series. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  1. Minimal internal fixation augmented by small wire transfixion frames for high-energy tibial plateau fractures.

    PubMed

    Katsenis, Dimitris; Athanasiou, Vasilis; Vasilis, Athanasiou; Megas, Panayiotis; Panayiotis, Megas; Tyllianakis, Minos; Minos, Tillianakis; Lambiris, Elias

    2005-04-01

    To evaluate the outcome of bicondylar tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames and to assess the necessity of bridging the knee joint by extending the external fixation to the distal femur. This is a retrospective study of 48 tibial plateau fractures. There were 40 (83.5%) Schatzker type VI fractures, 8 Schatzker type V fractures, and 18 (37.5%) fractures were open. A complex injury according to the Tscherne-Lobenhoffer classification was recorded in 30 (62.5%) patients. All fractures were treated with combined minimally invasive internal and external fixation. Closed reduction was achieved in 32 (66.6%) of the fractures. Extension of the external fixation to the distal femur was done in 30 (62.5%) fractures. Results were assessed according to the criteria of Honkonen-Jarvinen. Follow-up ranged from 28 to 60 months with an average of 38 months. All fractures but 1 united at an average of 13.5 weeks (range 11-18 weeks). One patient developed an infected nonunion of the diaphyseal segment of his fracture. Thirty-nine (81%) patients achieved an excellent or good radiologic result. An excellent or good final clinical result was recorded in 36 patients (76%). Bridging the knee joint did not affect significantly the result (P < 0.418). No significant correlation was found between the type of fracture and the final score (P < 0.458). Hybrid internal and external fixation combined with tibiofemoral extension of the fixation is an attractive treatment option for complex tibial plateau fractures.

  2. Characterization and Management of Mandibular Fractures: Lessons Learned from Iraq and Afghanistan

    DTIC Science & Technology

    2013-03-01

    Anatomic reduction is the goal. In complex fractures, maintain large segments of bone and obtain soft tissue coverage. Atlas Oral Maxillofacial Surg...conflicts of Iraq and Afghanistan. J Oral Maxillofac Surg 2010;68(1):3e7; with permission.) Fig. 2 Complex facial injury with avulsive tissue loss...a point distant from the site of injury Complicated (complex)dfracture with considerable injury to the adjacent soft tissue or adjacent parts, may

  3. Hydraulic Fracture Extending into Network in Shale: Reviewing Influence Factors and Their Mechanism

    PubMed Central

    Ren, Lan; Zhao, Jinzhou; Hu, Yongquan

    2014-01-01

    Hydraulic fracture in shale reservoir presents complex network propagation, which has essential difference with traditional plane biwing fracture at forming mechanism. Based on the research results of experiments, field fracturing practice, theory analysis, and numerical simulation, the influence factors and their mechanism of hydraulic fracture extending into network in shale have been systematically analyzed and discussed. Research results show that the fracture propagation in shale reservoir is influenced by the geological and the engineering factors, which includes rock mineral composition, rock mechanical properties, horizontal stress field, natural fractures, treating net pressure, fracturing fluid viscosity, and fracturing scale. This study has important theoretical value and practical significance to understand fracture network propagation mechanism in shale reservoir and contributes to improving the science and efficiency of shale reservoir fracturing design. PMID:25032240

  4. Image-Guided Surgical Robotic System for Percutaneous Reduction of Joint Fractures.

    PubMed

    Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2017-11-01

    Complex joint fractures often require an open surgical procedure, which is associated with extensive soft tissue damages and longer hospitalization and rehabilitation time. Percutaneous techniques can potentially mitigate these risks but their application to joint fractures is limited by the current sub-optimal 2D intra-operative imaging (fluoroscopy) and by the high forces involved in the fragment manipulation (due to the presence of soft tissue, e.g., muscles) which might result in fracture malreduction. Integration of robotic assistance and 3D image guidance can potentially overcome these issues. The authors propose an image-guided surgical robotic system for the percutaneous treatment of knee joint fractures, i.e., the robot-assisted fracture surgery (RAFS) system. It allows simultaneous manipulation of two bone fragments, safer robot-bone fixation system, and a traction performing robotic manipulator. This system has led to a novel clinical workflow and has been tested both in laboratory and in clinically relevant cadaveric trials. The RAFS system was tested on 9 cadaver specimens and was able to reduce 7 out of 9 distal femur fractures (T- and Y-shape 33-C1) with acceptable accuracy (≈1 mm, ≈5°), demonstrating its applicability to fix knee joint fractures. This study paved the way to develop novel technologies for percutaneous treatment of complex fractures including hip, ankle, and shoulder, thus representing a step toward minimally-invasive fracture surgeries.

  5. Diabetic calcaneal fractures.

    PubMed

    Sagray, Bryan A; Stapleton, John J; Zgonis, Thomas

    2013-01-01

    Calcaneal fractures among the diabetic population are severe and complex injuries that warrant careful evaluation in an effort to carry out adequate conservative or surgical management. The complication rates associated with diabetic fracture management are increased and may include poor wound healing, deep infection, malunion, and Charcot neuroarthropathy, each of which can pose a risk for limb loss. The significant surgery-associated morbidity accompanying diabetic calcaneal fractures has led to improved methods of calcaneal fracture management. This article reviews the overall management of diabetic calcaneal fractures, complications, and outcomes. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. HYDRAULIC CHARACTERIZATION FOR STEAM ENHANCED REMEDIATION CONDUCTED IN FRACTURED ROCK

    EPA Science Inventory

    Remediation of fractured rock sites contaminated by non-aqueous phase liquids has long been recognized as the most difficult undertaking of any site clean-up. This is primarily the result of the complexity of the fracture framework, which governs the groundwater flow pathways and...

  7. A Numerical Study of Factors Affecting Fracture-Fluid Cleanup and Produced Gas/Water in Marcellus Shale: Part II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seales, Maxian B.; Dilmore, Robert; Ertekin, Turgay

    Horizontal wells combined with successful multi-stage hydraulic fracture treatments are currently the most established method for effectively stimulating and enabling economic development of gas bearing organic-rich shale formations. Fracture cleanup in the Stimulated Reservoir Volume (SRV) is critical to stimulation effectiveness and long-term well performance. However, fluid cleanup is often hampered by formation damage, and post-fracture well performance frequently falls below expectations. A systematic study of the factors that hinder fracture fluid cleanup in shale formations can help optimize fracture treatments and better quantify long term volumes of produced water and gas. Fracture fluid cleanup is a complex process influencedmore » by multi-phase flow through porous media (relative permeability hysteresis, capillary pressure etc.), reservoir rock and fluid properties, fracture fluid properties, proppant placement, fracture treatment parameters, and subsequent flowback and field operations. Changing SRV and fracture conductivity as production progresses further adds to the complexity of this problem. Numerical simulation is the best, and most practical approach to investigate such a complicated blend of mechanisms, parameters, their interactions, and subsequent impact on fracture fluid cleanup and well deliverability. In this paper, a 3-dimensional, 2-phase, dual-porosity model was used to investigate the impact of multiphase flow, proppant crushing, proppant diagenesis, shut-in time, reservoir rock compaction, gas slippage, and gas desorption on fracture fluid cleanup, and well performance in Marcellus shale. The research findings have shed light on the factors that substantially constrains efficient fracture fluid cleanup in gas shales, and provided guidelines for improved fracture treatment designs and water management.« less

  8. Scaling Laws of Discrete-Fracture-Network Models

    NASA Astrophysics Data System (ADS)

    Philippe, D.; Olivier, B.; Caroline, D.; Jean-Raynald, D.

    2006-12-01

    The statistical description of fracture networks through scale still remains a concern for geologists, considering the complexity of fracture networks. A challenging task of the last 20-years studies has been to find a solid and rectifiable rationale to the trivial observation that fractures exist everywhere and at all sizes. The emergence of fractal models and power-law distributions quantifies this fact, and postulates in some ways that small-scale fractures are genetically linked to their larger-scale relatives. But the validation of these scaling concepts still remains an issue considering the unreachable amount of information that would be necessary with regards to the complexity of natural fracture networks. Beyond the theoretical interest, a scaling law is a basic and necessary ingredient of Discrete-Fracture-Network models (DFN) that are used for many environmental and industrial applications (groundwater resources, mining industry, assessment of the safety of deep waste disposal sites, ..). Indeed, such a function is necessary to assemble scattered data, taken at different scales, into a unified scaling model, and to interpolate fracture densities between observations. In this study, we discuss some important issues related to scaling laws of DFN: - We first describe a complete theoretical and mathematical framework that takes account of both the fracture- size distribution and the fracture clustering through scales (fractal dimension). - We review the scaling laws that have been obtained, and we discuss the ability of fracture datasets to really constrain the parameters of the DFN model. - And finally we discuss the limits of scaling models.

  9. Identification and characterisation of individual Fractures in 3D fracture-network of shale reservoir rocks from microtomography

    NASA Astrophysics Data System (ADS)

    Qi, C.; Liu, J.

    2017-12-01

    Fractures are essential for unconventional hydrocarbon production. However, the observation of fractures in three-dimensional (3D) space is very difficult except using microtomography to obtain 3D fracture structures at micro-scales. Twelve shale samples taken from a specimen are analyzed in this study: six of them were isobarically and five were isothermally processed in experiments of simulating hydrocarbon generation and expulsion and one is unprocessed. The resolutions of microtomographic images are in the range from 5.83 to 9.12 μm. Fractures developed in different complexities: some samples have mostly parallel fractures, some have major parallel fractures plus irregular fractures forming crack-network and some samples have fully intersected fractures of various directions. To identify individual fractures in 3D network is crucial for the characterization of fractures and it needs to separate each fractures or disconnect intersections of fractures. For those samples with fewer intersections, it is not difficult to disconnect intersections manually slice by slice using Avizo®. For those samples with complex intersections, it is impractical to process manually. A patented method and corresponding programs are used to separate, identify and characterize individual fractures. By procedures of filtering, smoothing, thinning, separating and combining, intersected cracks are separated, the segments of a broken elongated cracks are identified as one crack, and the thinned thickness is restored, finally the shape, orientation and dimensions of individual fractures are characterized. Our results show that: 1) relatively large fractures are very thin, showing typical fracture morphology, while small fractures may have various shapes; 2) isothermal processed samples have stronger anisotropy, which implies that the fractures in isothermal series are thinner or flatter than in isobaric series; 3) the fractal dimension exists in the samples and there is good correlation between the fractal dimension and temperature/pressure. This study is a first trial of the characterization of individual cracks in 3D network. It lays a foundation for future research on the prediction of large-scale fractures in tight reservoirs.

  10. Fractography of induction-hardened steel fractured in fatigue and overload

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santos, C.G.; Laird, C.

    1997-07-01

    The fracture surfaces of induction-hardened steel specimens obtained from an auto axle were characterized, macroscopically and microscopically, after being fractured in fatigue and monotonic overload. Specimens were tested in cyclic three-point bending under load control, and the S-N curve was established for specimens that had been notched by spark machining to facilitate fractography. Scanning electron microscopy of the fractured surfaces obtained for lives spanning the range 17,000 to 418,000 cycles revealed diverse fracture morphologies, including intergranular fracture and transgranular fatigue fracture. The results are being offered to assist in the analysis of complex field failures in strongly hardened steel.

  11. A constrained Delaunay discretization method for adaptively meshing highly discontinuous geological media

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Ma, Guowei; Ren, Feng; Li, Tuo

    2017-12-01

    A constrained Delaunay discretization method is developed to generate high-quality doubly adaptive meshes of highly discontinuous geological media. Complex features such as three-dimensional discrete fracture networks (DFNs), tunnels, shafts, slopes, boreholes, water curtains, and drainage systems are taken into account in the mesh generation. The constrained Delaunay triangulation method is used to create adaptive triangular elements on planar fractures. Persson's algorithm (Persson, 2005), based on an analogy between triangular elements and spring networks, is enriched to automatically discretize a planar fracture into mesh points with varying density and smooth-quality gradient. The triangulated planar fractures are treated as planar straight-line graphs (PSLGs) to construct piecewise-linear complex (PLC) for constrained Delaunay tetrahedralization. This guarantees the doubly adaptive characteristic of the resulted mesh: the mesh is adaptive not only along fractures but also in space. The quality of elements is compared with the results from an existing method. It is verified that the present method can generate smoother elements and a better distribution of element aspect ratios. Two numerical simulations are implemented to demonstrate that the present method can be applied to various simulations of complex geological media that contain a large number of discontinuities.

  12. Haptic computer-assisted patient-specific preoperative planning for orthopedic fractures surgery.

    PubMed

    Kovler, I; Joskowicz, L; Weil, Y A; Khoury, A; Kronman, A; Mosheiff, R; Liebergall, M; Salavarrieta, J

    2015-10-01

    The aim of orthopedic trauma surgery is to restore the anatomy and function of displaced bone fragments to support osteosynthesis. For complex cases, including pelvic bone and multi-fragment femoral neck and distal radius fractures, preoperative planning with a CT scan is indicated. The planning consists of (1) fracture reduction-determining the locations and anatomical sites of origin of the fractured bone fragments and (2) fracture fixation-selecting and placing fixation screws and plates. The current bone fragment manipulation, hardware selection, and positioning processes based on 2D slices and a computer mouse are time-consuming and require a technician. We present a novel 3D haptic-based system for patient-specific preoperative planning of orthopedic fracture surgery based on CT scans. The system provides the surgeon with an interactive, intuitive, and comprehensive, planning tool that supports fracture reduction and fixation. Its unique features include: (1) two-hand haptic manipulation of 3D bone fragments and fixation hardware models; (2) 3D stereoscopic visualization and multiple viewing modes; (3) ligaments and pivot motion constraints to facilitate fracture reduction; (4) semiautomatic and automatic fracture reduction modes; and (5) interactive custom fixation plate creation to fit the bone morphology. We evaluate our system with two experimental studies: (1) accuracy and repeatability of manual fracture reduction and (2) accuracy of our automatic virtual bone fracture reduction method. The surgeons achieved a mean accuracy of less than 1 mm for the manual reduction and 1.8 mm (std [Formula: see text] 1.1 mm) for the automatic reduction. 3D haptic-based patient-specific preoperative planning of orthopedic fracture surgery from CT scans is useful and accurate and may have significant advantages for evaluating and planning complex fractures surgery.

  13. Multiscale model reduction for shale gas transport in poroelastic fractured media

    NASA Astrophysics Data System (ADS)

    Akkutlu, I. Yucel; Efendiev, Yalchin; Vasilyeva, Maria; Wang, Yuhe

    2018-01-01

    Inherently coupled flow and geomechanics processes in fractured shale media have implications for shale gas production. The system involves highly complex geo-textures comprised of a heterogeneous anisotropic fracture network spatially embedded in an ultra-tight matrix. In addition, nonlinearities due to viscous flow, diffusion, and desorption in the matrix and high velocity gas flow in the fractures complicates the transport. In this paper, we develop a multiscale model reduction approach to couple gas flow and geomechanics in fractured shale media. A Discrete Fracture Model (DFM) is used to treat the complex network of fractures on a fine grid. The coupled flow and geomechanics equations are solved using a fixed stress-splitting scheme by solving the pressure equation using a continuous Galerkin method and the displacement equation using an interior penalty discontinuous Galerkin method. We develop a coarse grid approximation and coupling using the Generalized Multiscale Finite Element Method (GMsFEM). GMsFEM constructs the multiscale basis functions in a systematic way to capture the fracture networks and their interactions with the shale matrix. Numerical results and an error analysis is provided showing that the proposed approach accurately captures the coupled process using a few multiscale basis functions, i.e. a small fraction of the degrees of freedom of the fine-scale problem.

  14. Dynamic Fracture Behavior of Plastic-Bonded Explosives

    NASA Astrophysics Data System (ADS)

    Fu, Hua; Li, Jun-Ling; Tan, Duo-Wang; Ifp, Caep Team

    2011-06-01

    Plastic-Bonded Explosives (PBX) are used as important energetic materials in nuclear or conventional weapons. Arms Warhead in the service process and the ballistic phase, may experience complex process such as long pulse and higher loading, compresson, tension and reciprocating compression - tension, friction with the projectile shell, which would lead to explosive deformation and fracture.And the dynamic deformation and fracture behavior of PBX subsequently affect reaction characteristics and initiation mechanism in explosives, then having influence on explosives safety. The dynamic fracure behavior of PBX are generally complex and not well studied or understood. In this paper, the dynamic fracture of explosives are conducted using a Kolsky bar. The Brazilian test, also known as a indirect tensile test or splitting test, is chosen as the test method. Tensile strength under different strain rates are obtained using quartz crystal embedded in rod end. The dynamic deformation and fracture process are captured in real-time by high-speed digital camera, and the displacement and strain fields distribution before specimen fracture are obtained by digital correlation method. Considering the non-uniform microstructure of explosives,the dynamic fracture behavior of explosive are simulated by discrete element method, the simulation results can reproduce the deformation and fracture process in Brazilian test using a maximum tensile strain criterion.

  15. Coblation vertebroplasty for complex vertebral insufficiency fractures.

    PubMed

    Wilson, David J; Owen, Sara; Corkill, Rufus A

    2013-07-01

    Coblation to create a cavity in the affected vertebral body was performed for complex fractures and/or when there was a posterior wall defect. This permitted a low-pressure injection and potentially reduces the risk of extravasation of cement into the spinal canal. Prospective audit for outcome measures and complications allowed retrospective review of cases treated by coblation. A commercial wand inserted via a wide-bore vertebroplasty needle created a cavity before inserting cement. A visual analogue scale assessed pain and Roland Morris scoring assessed mobility. Thirty-two coblation procedures were performed. Primary diagnoses were myeloma, metastases, osteoporosis and trauma. Outcome measures were recorded with a 56 % success rate, 6 % no change and 32 % with mixed but mainly positive results; 6 % died before follow-up. No complications were observed; in particular no patient suffered neurological damage and none have developed subsequent fractures at the treated levels. This technique makes possible cementation of patients who would otherwise be unsuitable for vertebroplasty. The modest pain and disability improvement is partly due to our stringent criteria as well as fracture complexity. Further work will assess the efficacy of the method compared with conservative measures. • Treatment of vertebral compression fractures with possible posterior wall defects is controversial. • Coblation before vertebroplasty allows a low-pressure injection into fractured vertebrae. • This technique reduces risk of extravasation of cement. • No serious complication of our coblation procedures was observed.

  16. Gas-Driven Fracturing of Saturated Granular Media

    NASA Astrophysics Data System (ADS)

    Campbell, James M.; Ozturk, Deren; Sandnes, Bjørnar

    2017-12-01

    Multiphase flows in deformable porous materials are important in numerous geological and geotechnical applications; however, the complex flow behavior makes subsurface transport processes difficult to control—or even characterize. Here, we study gas-driven (pneumatic) fracturing of a wet unconsolidated granular packing confined in a Hele-Shaw cell, and we present an in-depth analysis of both pore-scale phenomena and large-scale pattern formation. The process is governed by a complex interplay among pressure, capillary, frictional, and viscous forces. At low gas-injection rates, fractures grow in a stick-slip fashion and branch out to form a simply connected network. We observe the emergence of a characteristic length scale—the separation distance between fracture branches—creating an apparent uniform spatial fracture density. We conclude that the well-defined separation distance is the result of local compaction fronts surrounding fractures and keeping them apart. A scaling argument is presented that predicts fracture density as a function of granular friction, grain size, and capillary interactions. We study the influence of the gas-injection rate and find that the system undergoes a fluidization transition above a critical injection rate, resulting in directional growth of the fractures, and a fracture density that increases with an increasing rate. A dimensionless fluidization number F is defined as the ratio of viscous to frictional forces, and our experiments reveal a frictional regime for F <1 characterized by stick-slip, rate-independent growth, with a transition to a viscous regime (F >1 ) characterized by continuous growth in several fracture branches simultaneously.

  17. Decision-making for complex scapula and ipsilateral clavicle fractures: a review.

    PubMed

    Hess, Florian; Zettl, Ralph; Smolen, Daniel; Knoth, Christoph

    2018-03-23

    Complex scapula with ipsilateral clavicle fracures remains a challange and treatment recommendations are still missing.  This review provides an overview of the evolution of the definition, classification and treatment strategies for complex scapula and ipsilateral clavicle fractures. As with other rare conditions, consensus has not been reached on the most suitable management strategies to treat these patients. The aim of this review is twofold: to compile and summarize the currently available literature on this topic, and to recommend treatment approaches. Included in the review are the following topics: biomechanics of scapula and ipsilateral clavicle fractures, preoperative radiological evaluation, surgical treatment of the clavicle only, surgical treatment of both the clavicle and scapula, and nonsurgical treatment options. A decision-making algorithm is proposed for different treatment strategies based on pre-operative parameters, and an example of a case treated our institution is presented to illustrate use of the algorithm. The role of instability in complex scapula with ipsilateral clavicle fractures remains unclear. The question of stability is preoperatively less relevant than the question of whether the dislocated fragments lead to compromised shoulder function.

  18. Natural time analysis of critical phenomena: The case of pre-fracture electromagnetic emissions

    NASA Astrophysics Data System (ADS)

    Potirakis, S. M.; Karadimitrakis, A.; Eftaxias, K.

    2013-06-01

    Criticality of complex systems reveals itself in various ways. One way to monitor a system at critical state is to analyze its observable manifestations using the recently introduced method of natural time. Pre-fracture electromagnetic (EM) emissions, in agreement to laboratory experiments, have been consistently detected in the MHz band prior to significant earthquakes. It has been proposed that these emissions stem from the fracture of the heterogeneous materials surrounding the strong entities (asperities) distributed along the fault, preventing the relative slipping. It has also been proposed that the fracture of heterogeneous material could be described in analogy to the critical phase transitions in statistical physics. In this work, the natural time analysis is for the first time applied to the pre-fracture MHz EM signals revealing their critical nature. Seismicity and pre-fracture EM emissions should be two sides of the same coin concerning the earthquake generation process. Therefore, we also examine the corresponding foreshock seismic activity, as another manifestation of the same complex system at critical state. We conclude that the foreshock seismicity data present criticality features as well.

  19. Natural time analysis of critical phenomena: the case of pre-fracture electromagnetic emissions.

    PubMed

    Potirakis, S M; Karadimitrakis, A; Eftaxias, K

    2013-06-01

    Criticality of complex systems reveals itself in various ways. One way to monitor a system at critical state is to analyze its observable manifestations using the recently introduced method of natural time. Pre-fracture electromagnetic (EM) emissions, in agreement to laboratory experiments, have been consistently detected in the MHz band prior to significant earthquakes. It has been proposed that these emissions stem from the fracture of the heterogeneous materials surrounding the strong entities (asperities) distributed along the fault, preventing the relative slipping. It has also been proposed that the fracture of heterogeneous material could be described in analogy to the critical phase transitions in statistical physics. In this work, the natural time analysis is for the first time applied to the pre-fracture MHz EM signals revealing their critical nature. Seismicity and pre-fracture EM emissions should be two sides of the same coin concerning the earthquake generation process. Therefore, we also examine the corresponding foreshock seismic activity, as another manifestation of the same complex system at critical state. We conclude that the foreshock seismicity data present criticality features as well.

  20. Integrated Modeling and Experiments to Characterize Coupled Thermo-hydro-geomechanical-chemical processes in Hydraulic Fracturing

    NASA Astrophysics Data System (ADS)

    Viswanathan, H. S.; Carey, J. W.; Karra, S.; Porter, M. L.; Rougier, E.; Kang, Q.; Makedonska, N.; Hyman, J.; Jimenez Martinez, J.; Frash, L.; Chen, L.

    2015-12-01

    Hydraulic fracturing phenomena involve fluid-solid interactions embedded within coupled thermo-hydro-mechanical-chemical (THMC) processes over scales from microns to tens of meters. Feedbacks between processes result in complex dynamics that must be unraveled if one is to predict and, in the case of unconventional resources, facilitate fracture propagation, fluid flow, and interfacial transport processes. The proposed work is part of a broader class of complex systems involving coupled fluid flow and fractures that are critical to subsurface energy issues, such as shale oil, geothermal, carbon sequestration, and nuclear waste disposal. We use unique LANL microfluidic and triaxial core flood experiments integrated with state-of-the-art numerical simulation to reveal the fundamental dynamics of fracture-fluid interactions to characterize the key coupled processes that impact hydrocarbon production. We are also comparing CO2-based fracturing and aqueous fluids to enhance production, greatly reduce waste water, while simultaneously sequestering CO2. We will show pore, core and reservoir scale simulations/experiments that investigate the contolling mechanisms that control hydrocarbon production.

  1. [Intramedullary stabilisation of displaced midshaft clavicular fractures: does the fracture pattern (simple vs. complex) influence the anatomic and functional result].

    PubMed

    Langenhan, R; Reimers, N; Probst, A

    2014-12-01

    Displaced midshaft clavicular fractures are often treated operatively. The most common way of treatment is plating. Elastic stable intramedullary nailing (ESIN) is an alternative, but seldom used. Studies showed comparable or even better results for intramedullary nailing than for plating in simple 2- or 3-fragment midshaft fractures. The indication of ESIN for multifragmentary clavicular fractures is discussed critically in the literature because of reduced primary stability and danger of secondary shortening. Until now only few studies report functional results after fracture healing depending on the fracture type. To the best of our knowledge there is no study showing significantly worse functional scores for ESIN in complex displaced midshaft fractures. The objective of this study was to examine anatomic and functional results of simple (2 or 3 fragments, OTA type 15B1 and 15B2) and complex (multifragmentary, OTA type 15B3) displaced midshaft clavicula fractures after internal fixation. Between 2009 and 2012, 40 patients (female/male 10/30; mean age 33 [16-60] years) with closed displaced midshaft clavicular fractures were treated by open reduction and ESIN (Titanium Elastic Nail [TEN], Synthes, Umkirch, Germany). Thirty-seven patients were retrospectively analysed after a mean of 27 (12-43) months. Twenty patients (group A) had simple fractures (OTA type 15B1 and 15B2), 17 patients (group B) had complex fractures (OTA type 15B3). All shoulder joints were postoperatively treated functionally for six weeks without weight limited to 90° abduction/flexion. Both groups were comparable in gender, age, body mass index, months until metal removal, number of physiotherapy sessions and time until follow-up examination. Joint function (neutral zero method) and strength (standing patient with arm in 90° abduction, holding 1-12 kg for 5 sec) in both shoulders were documented. The distance between the centre of the jugulum and the lateral acromial border was measured for both sides. The DASH, Constant-Murley, Oxford shoulder and clavicular scores (Jubel) were calculated. Patients documented contentedness of outcome by VAS between 0 (absolute discontented) and 10 (very contented). Complications were recorded. Operatively treated displaced midshaft clavicular fractures. in comparison to the healthy side in group A had an average shortening of 5 (0-20) mm and in group B of 10 (3-25) mm, with a statistical significance between both groups. Patients of both groups were very contented with the results (VAS group A: 9.6; B: 9.5). DASH score (group A: 28; B: 3.1), Constant-Murley score (group A: 95.0; B: 93.8), Oxford shoulder score (group A: 46.2; B: 45.9) and the clavicula score (Jubel) (group A: 1.2; B: 2.1) were comparable between both groups without significance. In 4 patients (11%) complications occurred. Once (group B) an infection was seen, three times (group B) the ESIN had to be shortened on the medial side because of telescoping. Open ESIN of simple and complex displaced midshaft clavicular fractures leads after an average of 27 months to good or even excellent results. Healing of the clavicle in a modestly shortened position does not impair the patient. Georg Thieme Verlag KG Stuttgart · New York.

  2. A theoretical and experimental technique to measure fracture properties in viscoelastic solids

    NASA Astrophysics Data System (ADS)

    Freitas, Felipe Araujo Colares De

    Prediction of crack growth in engineering structures is necessary for better analysis and design. However, this prediction becomes quite complex for certain materials in which the fracture behavior is both rate and path dependent. Asphaltic materials used in pavements have that intrinsic complexity in their behavior. A lot of research effort has been devoted to better understanding viscoelastic behavior and fracture in such materials. This dissertation presents a further refinement of an experimental test setup, which is significantly different from standard testing protocols, to measure viscoelastic and fracture properties of nonlinear viscoelastic solids, such as asphaltic materials. The results presented herein are primarily for experiments with asphalt, but the test procedure can be used for other viscoelastic materials as well. Even though the test is designed as a fracture test, experiments on the investigated materials have uncovered very complex phenomena prior to fracture. Viscoelasticity and micromechanics are used to explain some of the physical phenomena observed in the tests. The material behavior prior to fracture includes both viscoelastic behavior and a necking effect, which is further discussed in the appendix of the present study. The dissertation outlines a theoretical model for the prediction of tractions ahead of the crack tip. The major contribution herein lies in the development of the experimental procedure for evaluating the material parameters necessary for deploying the model in the prediction of ductile crack growth. Finally, predictions of crack growth in a double cantilever beam specimens and asphalt concrete samples are presented in order to demonstrate the power of this approach for predicting crack growth in viscoelastic media.

  3. Surgical and functional outcomes after operative management of complex and displaced intra-articular glenoid fractures.

    PubMed

    Anavian, Jack; Gauger, Erich M; Schroder, Lisa K; Wijdicks, Coen A; Cole, Peter A

    2012-04-04

    Operative treatment is indicated for displaced fractures of the glenoid fossa. However, little is known regarding functional outcomes in these patients. This study assesses surgical and functional results after treatment of displaced, high-energy, complex, intra-articular glenoid fractures. Thirty-three patients with displaced intra-articular fractures of the glenoid were treated surgically between 2002 and 2009. The indications for operative treatment included articular fracture gap or step-off of ≥ 4 mm. Twenty-five patients also had extra-articular scapular involvement. A posterior approach was utilized in twenty-one patients, an anterior approach in seven, and a combined approach in five. Functional outcomes, including Disabilities of the Arm, Shoulder and Hand (DASH) and Short Form-36 (SF-36) scores, shoulder motion and strength, and return to work and/or activities, were obtained for thirty patients (91%). At a mean follow-up of twenty-seven months (range, twelve to seventy-three months), all patients had radiographic union of the fracture. The mean DASH score was 10.8 (range, 0 to 42). All mean SF-36 subscores were comparable with those of the normal population. Twenty-six patients (87%) were pain-free at the time of follow-up, and four had mild pain with prolonged activity. Twenty-seven (90%) of thirty patients returned to their preinjury level of work and/or activities. Our data suggest that surgical treatment for complex, displaced intra-articular glenoid fractures with or without involvement of the scapular neck and body can be associated with good functional outcomes and a low complication rate.

  4. Comparative study of the prognosis of an extracorporeal reduction and a closed treatment in mandibular condyle head and/or neck fractures.

    PubMed

    Park, Jung-Min; Jang, Yong-Wook; Kim, Seong-Gon; Park, Young-Wook; Rotaru, Horatiu; Baciut, Grigore; Hurubeanu, Lucia

    2010-12-01

    The objective of this study was a comparison of the prognosis between an extracorporeal reduction technique and closed treatment of a mandibular condyle fracture. The relationship between condylar resorption and several clinical variables was also studied. Seventy-one patients who had a mandibular condyle fracture took part in this study. Thirty-five patients (female: 7, male: 28, age: 30.46 ± 14.27 years) were treated by extracorporeal reduction, and 36 patients (male: 24, female: 12, age: 24.28 ± 9.99 years) were treated using a closed treatment. The presence of complications such as condylar resorption, malocclusion, nerve disorder, and disc displacement was evaluated with panoramic radiographs and clinical examinations 12 months after treatment. The relationships between the complications and other clinical variables were evaluated statistically. The anatomic site and fracture type were closely related to condyle resorption in the bivariate analysis. Condylar head fractures showed significantly higher condyle resorption than condylar neck fractures (P = .023). A complex or compound fracture showed significantly higher condyle resorption compared with a simple fracture (P = .006). Patients who had a complex/compound fracture were 34.366 times more likely to have condyle resorption compared with those who had a simple fracture (P = .002). The patient's age and treatment method were also significant predictors for condyle resorption. Fracture type was the strongest predictor of condylar resorption. Because treatment method and patient age were also related to the prognosis, the optimal treatment for mandibular condylar head and/or neck fractures should be individualized according to the patient's condition. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Recent Advances and Developments in Knee Surgery: Principles of Periprosthetic Knee Fracture Management

    PubMed Central

    Chimutengwende-Gordon, Mukai; Khan, Wasim; Johnstone, David

    2012-01-01

    The management of distal femoral, tibial and patellar fractures after total knee arthroplasty can be complex. The incidence of these fractures is increasing as the number of total knee arthroplasties being performed and patient longevity is increasing. There is a wide range of treatment options including revision arthroplasty for loose implants. This review article discusses the epidemiology, risk factors, classification and treatment of these fractures. PMID:22888380

  6. Repair of Acute Superficial Deltoid Complex Avulsion During Ankle Fracture Fixation in National Football League Players.

    PubMed

    Hsu, Andrew R; Lareau, Craig R; Anderson, Robert B

    2015-11-01

    Infolding and retraction of an avulsed deltoid complex after ankle fracture can be a source of persistent increased medial clear space, malreduction, and postoperative pain and medial instability. The purpose of this descriptive case series was to analyze the preliminary outcomes of acute superficial deltoid complex avulsion repair during ankle fracture fixation in a cohort of National Football League (NFL) players. We found that there is often complete avulsion of the superficial deltoid complex off the proximal aspect of the medial malleolus during high-energy ankle fractures in athletes. Between 2004 and 2014, the cases of 14 NFL players who underwent ankle fracture fixation with open deltoid complex repair were reviewed. Patients with chronic deltoid ligament injuries or ankle fractures more than 2 months old were excluded. Average age for all patients was 25 years and body mass index 34.4. Player positions included 1 wide receiver, 1 tight end, 1 safety, 1 running back, 1 linebacker, and 9 offensive linemen. Average time from injury to surgery was 7.5 days. Surgical treatment for all patients consisted of ankle arthroscopy and debridement, followed by fibula fixation with plate and screws, syndesmotic fixation with suture-button devices, and open deltoid complex repair with suture anchors. Patient demographics were recorded with position played, time from injury to surgery, games played before and after surgery, ability to return to play, and postoperative complications. Return to play was defined as the ability to successfully participate in at least 1 full regular-season NFL game after surgery. All NFL players were able to return to running and cutting maneuvers by 6 months after surgery. There were no significant differences in playing experience before surgery versus after surgery. Average playing experience before surgery was 3.3 seasons, 39 games played, and 22 games started. Average playing experience after surgery was 1.6 seasons, 16 games played, and 15 games started. Return to play was 86% for all players. There were no intraoperative or postoperative complications noted, and no players had clinical evidence of medial pain or instability at final follow-up with radiographic maintenance of anatomic mortise alignment. Superficial deltoid complex avulsion during high-energy ankle fractures in athletes is a distinct injury pattern that should be recognized and may benefit from primary open repair. The majority of NFL players treated surgically for this injury pattern are able to return to play after surgery with no reported complications or persistent medial ankle pain or instability. Level IV, retrospective case series. © The Author(s) 2015.

  7. Geoelectrical characterisation of basement aquifers: the case of Iberekodo, southwestern Nigeria

    NASA Astrophysics Data System (ADS)

    Aizebeokhai, Ahzegbobor P.; Oyeyemi, Kehinde D.

    2018-03-01

    Basement aquifers, which occur within the weathered and fractured zones of crystalline bedrocks, are important groundwater resources in tropical and subtropical regions. The development of basement aquifers is complex owing to their high spatial variability. Geophysical techniques are used to obtain information about the hydrologic characteristics of the weathered and fractured zones of the crystalline basement rocks, which relates to the occurrence of groundwater in the zones. The spatial distributions of these hydrologic characteristics are then used to map the spatial variability of the basement aquifers. Thus, knowledge of the spatial variability of basement aquifers is useful in siting wells and boreholes for optimal and perennial yield. Geoelectrical resistivity is one of the most widely used geophysical methods for assessing the spatial variability of the weathered and fractured zones in groundwater exploration efforts in basement complex terrains. The presented study focuses on combining vertical electrical sounding with two-dimensional (2D) geoelectrical resistivity imaging to characterise the weathered and fractured zones in a crystalline basement complex terrain in southwestern Nigeria. The basement aquifer was delineated, and the nature, extent and spatial variability of the delineated basement aquifer were assessed based on the spatial variability of the weathered and fractured zones. The study shows that a multiple-gradient array for 2D resistivity imaging is sensitive to vertical and near-surface stratigraphic features, which have hydrological implications. The integration of resistivity sounding with 2D geoelectrical resistivity imaging is efficient and enhances near-surface characterisation in basement complex terrain.

  8. Management of pediatric mandibular fracture: a case series.

    PubMed

    Agarwal, Ravi M; Yeluri, Ramakrishna; Singh, Chanchal; Chaudhry, Kalpna; Munshi, Autar K

    2014-09-01

    A pediatric mandibular fracture can cause a child severe pain and the parent or caregiver extreme worry. While the pattern of fractures and associated injuries in children is similar to adults, the incidence is low. Due to a number of factors, including the anatomical complexity of the developing mandible in a child, management of such fractures differs from that of adults and can greatly challenge the pediatric dentist. Various treatment modalities of managing mandibular fracture are available, such as closed/open cap splint with circummandibular wiring, arch-bar fixation, and cementation of the cap splint. This article reviews 19 cases in the management of pediatric facial fracture using varied treatment methods.

  9. Hemodynamic Deterioration in Lateral Compression Pelvic Fracture After Prehospital Pelvic Circumferential Compression Device Application.

    PubMed

    Garner, Alan A; Hsu, Jeremy; McShane, Anne; Sroor, Adam

    Increased fracture displacement has previously been described with the application of pelvic circumferential compression devices (PCCDs) in patients with lateral compression-type pelvic fracture. We describe the first reported case of hemodynamic deterioration temporally associated with the prehospital application of a PCCD in a patient with a complex acetabular fracture with medial displacement of the femoral head. Active hemorrhage from a site adjacent to the acetabular fracture was subsequently demonstrated on angiography. Caution in the application of PCCDs to patients with lateral compression-type fractures is warranted. Copyright © 2017 Air Medical Journal Associates. All rights reserved.

  10. [Treatment of periprosthetic and peri-implant fractures : modern plate osteosynthesis procedures].

    PubMed

    Raschke, M J; Stange, R; Kösters, C

    2012-11-01

    Periprosthetic fractures are increasing not only due to the demographic development with high life expectancy, the increase in osteoporosis and increased prosthesis implantation but also due to increased activity of the elderly population. The therapeutic algorithms are manifold but general valid rules for severe fractures are not available. The most commonly occurring periprosthetic fractures are proximal and distal femoral fractures but in the clinical routine fractures of the tibial head, ankle, shoulder, elbow and on the borders to other implants (peri-implant fractures) and complex interprosthetic fractures are being seen increasingly more. It is to be expected that in the mid-term further options, such as cement augmentation of cannulated polyaxial locking screws will extend the portfolio of implants for treatment of periprosthetic fractures. The aim of this review article is to present the new procedures for osteosynthesis of periprosthetic fractures.

  11. [Treatment of periprosthetic and peri-implant fractures : modern plate osteosynthesis procedures].

    PubMed

    Raschke, M J; Stange, R; Kösters, C

    2012-08-01

    Periprosthetic fractures are increasing not only due to the demographic development with high life expectancy, the increase in osteoporosis and increased prosthesis implantation but also due to increased activity of the elderly population. The therapeutic algorithms are manifold but general valid rules for severe fractures are not available. The most commonly occurring periprosthetic fractures are proximal and distal femoral fractures but in the clinical routine fractures of the tibial head, ankle, shoulder, elbow and on the borders to other implants (peri-implant fractures) and complex interprosthetic fractures are being seen increasingly more. It is to be expected that in the mid-term further options, such as cement augmentation of cannulated polyaxial locking screws will extend the portfolio of implants for treatment of periprosthetic fractures. The aim of this review article is to present the new procedures for osteosynthesis of periprosthetic fractures.

  12. Measurement of width and pressure in a propagating hydraulic fracture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warpinski, N.R.

    Measurements of width and pressure in a propagating hydraulic fracture have been made in tests conducted at DOE's Nevada Test Site. This was accomplished by creating an instrumented fracture at a tunnel complex (at a depth of 1400 ft) where realistic in situ conditions prevail, particularly with respect to stress and geologic features such as natural fractures and material anisotropy. Analyses of these data show that the pressure drop along the fracture length is much larger than predicted by viscous theory and currently in use in models today. This is apparently due to the tortuosity of the fracture path, multiplemore » fracture strands, roughness and sharp turns (corners) in the flow path due to natural fractures and rock property variations. It suggests that fracture design models need to be updated to include a more realistic friction factor so that fracture lengths are not overestimated.« less

  13. Multiwell fracturing experiments. [Nitrogen foam fracture treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warpinski, N.

    The objective of the Multiwell fracturing experiments is to test and develop the technology for the efficient stimulation of tight, lenticular gas sands. This requires basic understanding of: (1) fracture behavior and geometry in this complex lithologic environment, and (2) subsequent production into the created fracture. The intricate interplay of the hydraulic fracture with the lens geometry, the internal reservoir characteristics (fractures, reservoir breaks, etc.), the in situ stresses, and the mechanical defects (fracture, bedding, etc.) need to be defined in order to develop a successful stimulation program. The stimulation phase of the Multiwell Experiment is concerned with: (1) determiningmore » important rock/reservoir properties that influence or control fracture geometry and behavior, (2) designing fracture treatments to achieve a desired size and objectives, and (3) conducting post-treatment analyses to evaluate the effectiveness of the treatment. Background statement, project description, results and evaluation of future plans are presented. 5 refs., 2 figs., 2 tabs.« less

  14. Persistent ulnar-sided wrist pain after treatment of triquetral dorsal chip fracture: six cases related to triangular fibrocartilage complex injury.

    PubMed

    Lee, Seoung-joon; Rathod, Chasanal Mohan; Park, Kwang-Won; Hwang, Jin-Ho

    2012-05-01

    Persistent ulnar-sided wrist pain after treatment of triquetral dorsal chip fracture even after union is a matter of concern. There could be various reasons for this persistent pain like arthritis, instability, fractures and non-union. We correlate our findings of physical examination and wrist arthroscopy as triangular fibrocartilage complex injury to be one of the causes of this persistent pain. Six subjects who had persistent ulnocarpal joint pain and tenderness after triquetral dorsal chip fracture, despite 2 months of conservative treatment, were subjected to physical tests. If the physical examination yields positive results, then magnetic resonance imaging followed by arthroscopic treatment was performed. The six patients were then evaluated using the visual analogue scale, the Mayo modified wrist score, and the grip strength test. Triangular fibrocartilage complex (TFCC) injury was observed in all six cases and partial TFCC resection and synovectomy were performed. Analysis of the visual analogue scale, Mayo modified wrist score, and grip strength test data revealed statistically significant improvements (P < 0.05). In addition to several causes reported in the published literature, TFCC injury can be a cause of persistent ulnar pain after treatment of triquetral dorsal chip fracture. Arthroscopic partial TFCC resection can be considered to be a suitable treatment for such cases.

  15. Venus - Complex Network of Narrow Fractures Near Hestia Rupes Region

    NASA Image and Video Library

    1996-10-23

    This image from NASA Magellan spacecraft covers region near Hestia Rupes on the northwestern corner of Aphrodite Terra. The complex network of narrow (<1 kilometer) fractures in the center of the image extends for approximately 50 kilometers (31 miles). This network exhibits tributary-like branches similar to those observed in river systems on Earth. However, the angular intersections of tributaries suggest tectonic control. These features appear to be due to drainage of lava along preexisting fractures and subsequent collapse of the surface. The underlying tectonic fabric can be observed in the northeast trending ridges which predate the plains. http://photojournal.jpl.nasa.gov/catalog/PIA00469

  16. Principles of managing Vancouver type B periprosthetic fractures around cemented polished tapered femoral stems.

    PubMed

    Quah, Conal; Porteous, Matthew; Stephen, Arthur

    2017-05-01

    The management of periprosthetic fractures around total hip replacements is a complex and challenging problem. Getting it right first time is an important factor in reducing the morbidity, mortality and financial burden associated with these injuries. Understanding and applying the basic principles of fracture management helps increase the chance of successful treatment. Based on these principles, we suggest a treatment algorithm for managing periprosthetic fractures around polished tapered femoral stems.

  17. Simulation of Hydraulic and Natural Fracture Interaction Using a Coupled DFN-DEM Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, J.; Huang, H.; Deo, M.

    2016-03-01

    The presence of natural fractures will usually result in a complex fracture network due to the interactions between hydraulic and natural fracture. The reactivation of natural fractures can generally provide additional flow paths from formation to wellbore which play a crucial role in improving the hydrocarbon recovery in these ultra-low permeability reservoir. Thus, accurate description of the geometry of discrete fractures and bedding is highly desired for accurate flow and production predictions. Compared to conventional continuum models that implicitly represent the discrete feature, Discrete Fracture Network (DFN) models could realistically model the connectivity of discontinuities at both reservoir scale andmore » well scale. In this work, a new hybrid numerical model that couples Discrete Fracture Network (DFN) and Dual-Lattice Discrete Element Method (DL-DEM) is proposed to investigate the interaction between hydraulic fracture and natural fractures. Based on the proposed model, the effects of natural fracture orientation, density and injection properties on hydraulic-natural fractures interaction are investigated.« less

  18. Simulation of Hydraulic and Natural Fracture Interaction Using a Coupled DFN-DEM Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Zhou; H. Huang; M. Deo

    The presence of natural fractures will usually result in a complex fracture network due to the interactions between hydraulic and natural fracture. The reactivation of natural fractures can generally provide additional flow paths from formation to wellbore which play a crucial role in improving the hydrocarbon recovery in these ultra-low permeability reservoir. Thus, accurate description of the geometry of discrete fractures and bedding is highly desired for accurate flow and production predictions. Compared to conventional continuum models that implicitly represent the discrete feature, Discrete Fracture Network (DFN) models could realistically model the connectivity of discontinuities at both reservoir scale andmore » well scale. In this work, a new hybrid numerical model that couples Discrete Fracture Network (DFN) and Dual-Lattice Discrete Element Method (DL-DEM) is proposed to investigate the interaction between hydraulic fracture and natural fractures. Based on the proposed model, the effects of natural fracture orientation, density and injection properties on hydraulic-natural fractures interaction are investigated.« less

  19. Online Studies on Variation in Orthopedic Surgery: Computed Tomography in MPEG4 Versus DICOM Format.

    PubMed

    Mellema, Jos J; Mallee, Wouter H; Guitton, Thierry G; van Dijk, C Niek; Ring, David; Doornberg, Job N

    2017-10-01

    The purpose of this study was to compare the observer participation and satisfaction as well as interobserver reliability between two online platforms, Science of Variation Group (SOVG) and Traumaplatform Study Collaborative, for the evaluation of complex tibial plateau fractures using computed tomography in MPEG4 and DICOM format. A total of 143 observers started with the online evaluation of 15 complex tibial plateau fractures via either the SOVG or Traumaplatform Study Collaborative websites using MPEG4 videos or a DICOM viewer, respectively. Observers were asked to indicate the absence or presence of four tibial plateau fracture characteristics and to rate their satisfaction with the evaluation as provided by the respective online platforms. The observer participation rate was significantly higher in the SOVG (MPEG4 video) group compared to that in the Traumaplatform Study Collaborative (DICOM viewer) group (75 and 43%, respectively; P < 0.001). The median observer satisfaction with the online evaluation was seven (range, 0-10) using MPEG4 video compared to six (range, 1-9) using DICOM viewer (P = 0.11). The interobserver reliability for recognition of fracture characteristics in complex tibial plateau fractures was higher for the evaluation using MPEG4 video. In conclusion, observer participation and interobserver reliability for the characterization of tibial plateau fractures was greater with MPEG4 videos than with a standard DICOM viewer, while there was no difference in observer satisfaction. Future reliability studies should account for the method of delivering images.

  20. [Treatment of multi-segment fracture of complex femoral shaft with instrument-assisted reduction combined with intramedullary interlocking nail fixation].

    PubMed

    Fan, Ke-Jie; Chen, Ke; Ma, Wen-Long; Tian, Ke-Wei; Ye, Ye; Chen, Hong-Gan; Tang, Yan-Feng; Cai, Hong-Min

    2018-05-25

    To investigate the effect of minimally invasive mini-incision and instrumented reduction combined with interlocking intramedullary nailing in the treatment of patients with multi-segment fracture of complex femoral shaft. From January 2013 to January 2016, 32 patients with multiple fractures segments of femoral shaft were treated with instrumentation-assisted reduction combined with interlocking intramedullary nailing, including 22 males and 10 females with an average age of 45 years old ranging 17 to 68 years old. The time from injured to operation was 5 to 10 days with an average of 7 days. After admission, routine tibial tubercle or supracondylar bone traction was performed. The patient's general condition was evaluated, the operation time and intraoperative blood loss were recorded. According to Thorsen femoral fracture morphology evaluation criteria and Hohl knee function evaluation of postoperative efficacy, postoperative fracture healing, complications and postoperative recovery of limb function were observed. All patients were followed up for 6 to 24 months with an average of 12 months. The operative time ranged from 48 to 76 minutes with an average of 67 min. The intraoperative blood loss was 150 to 400 ml with an average of 220 ml. The surgical incisions all achieved grade A healing. The fractures reached the clinical standard of healing. The fracture healing time ranged from 4.2 to 10.8 months with an average of 5.7 months. There were no nonunion, incision infection and internal fixation fracture, failure and other complications. According to Thorsen femoral fracture morphology evaluation criteria, the result was excellent in 28 cases, good in 3 cases, fair in 1 case. According to Hohl knee function evaluation criteria, the result was excellent in 30 cases, good in 2 cases. Instrument-assisted reduction combined with interlocking intramedullary nail fixation is a safe and effective method for the treatment of complex femoral shaft fractures. It has advantages of small trauma, fixed fixation, quick recovery, early postoperative functional exercise. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  1. Transient pressure analysis of fractured well in bi-zonal gas reservoirs

    NASA Astrophysics Data System (ADS)

    Zhao, Yu-Long; Zhang, Lie-Hui; Liu, Yong-hui; Hu, Shu-Yong; Liu, Qi-Guo

    2015-05-01

    For hydraulic fractured well, how to evaluate the properties of fracture and formation are always tough jobs and it is very complex to use the conventional method to do that, especially for partially penetrating fractured well. Although the source function is a very powerful tool to analyze the transient pressure for complex structure well, the corresponding reports on gas reservoir are rare. In this paper, the continuous point source functions in anisotropic reservoirs are derived on the basis of source function theory, Laplace transform method and Duhamel principle. Application of construction method, the continuous point source functions in bi-zonal gas reservoir with closed upper and lower boundaries are obtained. Sequentially, the physical models and transient pressure solutions are developed for fully and partially penetrating fractured vertical wells in this reservoir. Type curves of dimensionless pseudo-pressure and its derivative as function of dimensionless time are plotted as well by numerical inversion algorithm, and the flow periods and sensitive factors are also analyzed. The source functions and solutions of fractured well have both theoretical and practical application in well test interpretation for such gas reservoirs, especial for the well with stimulated reservoir volume around the well in unconventional gas reservoir by massive hydraulic fracturing which always can be described with the composite model.

  2. TOUGH-RBSN simulator for hydraulic fracture propagation within fractured media: Model validations against laboratory experiments

    NASA Astrophysics Data System (ADS)

    Kim, Kunhwi; Rutqvist, Jonny; Nakagawa, Seiji; Birkholzer, Jens

    2017-11-01

    This paper presents coupled hydro-mechanical modeling of hydraulic fracturing processes in complex fractured media using a discrete fracture network (DFN) approach. The individual physical processes in the fracture propagation are represented by separate program modules: the TOUGH2 code for multiphase flow and mass transport based on the finite volume approach; and the rigid-body-spring network (RBSN) model for mechanical and fracture-damage behavior, which are coupled with each other. Fractures are modeled as discrete features, of which the hydrological properties are evaluated from the fracture deformation and aperture change. The verification of the TOUGH-RBSN code is performed against a 2D analytical model for single hydraulic fracture propagation. Subsequently, modeling capabilities for hydraulic fracturing are demonstrated through simulations of laboratory experiments conducted on rock-analogue (soda-lime glass) samples containing a designed network of pre-existing fractures. Sensitivity analyses are also conducted by changing the modeling parameters, such as viscosity of injected fluid, strength of pre-existing fractures, and confining stress conditions. The hydraulic fracturing characteristics attributed to the modeling parameters are investigated through comparisons of the simulation results.

  3. Second generation locked plating for complex proximal humerus fractures in very elderly patients.

    PubMed

    Gavaskar, Ashok S; Karthik B, Bhupesh; Tummala, Naveen C; Srinivasan, Parthasarathy; Gopalan, Hitesh

    2016-11-01

    Humeral head sacrificing procedures are more favored in elderly patients with complex proximal humerus fractures because of high incidence of failures and complications with osteosynthesis. The purpose of this study is to assess the outcome of second generation locked plating techniques in 3 and 4 part fractures in active elderly patients >70years with an emphasis on function and complications. 29 patients with displaced 3 and 4 part proximal humerus fractures were treated using the principles of second-generation proximal humerus locked plating. Fixed angle locked plating (PHILOS) using the anterolateral deltoid spilt approach augmented with traction cuff sutures was performed. Minimum of 7 locking head screws including 2 calcar screws were used. In cases with a comminuted medial calcar, an endosteal fibular strut was used. Subchondral metaphyseal bone voids were filled with injectable calcium phosphate cement. Radiological outcome (union, head - shaft angle, tuberosity reduction), functional outcome assessment (Constant and ASES scores) and complications (loss of reduction, nonunion and osteonecrosis) were assessed. The fracture united in 24 of the 26 patients available for follow up at a mean of 27 months (12-40 months). 3 patients developed complications that required arthroplasty (fixation failure in 2 patients and osteonecrosis in 1 patient). Follow up age adjusted Constant (63.1±11.9) and ASES scores (62.58±7.5) showed the extent of functional improvement post surgery. Patients with fractures having a non-comminuted medial calcar and valgus displacement of the humeral head had better functional scores and fewer complications. Osteosynthesis with second generation locked plating techniques provide satisfactory outcome in very elderly patients with complex proximal humerus fractures with minimal complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Sustainable Fracturing Rationale to Reach Well Objectives: the Impact of Uncertainties and Complexities on Compliance Assurances

    EPA Pesticide Factsheets

    The presentation will discuss lessons learned; extract best practices and guidelines applied to injection of fluids and slurries during fracturing and exploration and production associated streams disposal.

  5. Lunate fractures and associated radiocarpal and midcarpal instabilities: a systematic review.

    PubMed

    Shunmugam, Meenalochani; Phadnis, Joideep; Watts, Amy; Bain, Gregory I

    2018-01-01

    The aim of this study was to analyse lunate fractures and any associated osseo-ligamentous injuries. A systematic review identified 34 cases. We identified carpal instabilities at the radiocarpal and midcarpal joints in volar and dorsal directions. Radiocarpal instabilities (10/34) were usually dorsoradial (8/10), with a transverse lunate fracture, best seen on a coronal image. Midcarpal instabilities (24/34) were usually volar (14/18), with a volar lunate shear fracture, best seen on a sagittal image. Instabilities were sub-classified into non-displaced, subluxated and dislocated. Associated fractures of the scaphoid and the radial and ulnar styloid processes were common. Lunate fractures without subluxation or dislocation had good outcomes with cast immobilization or fixation of associated fractures. Lunate fracture-subluxations are unstable injuries that are best managed with fixation of the carpal fractures. Lunate fracture-dislocations are complex injuries, requiring stabilization of the lunate, associated fractures and ligament injuries; complications are common and acute or delayed salvage procedures may be required.

  6. [Dislocation of the ankle without simoustaneously fracture of the bones].

    PubMed

    Qayyum, Faiza; Qayyum, Abbas Ali; Sahlstrüm, Sven Arne

    2014-09-01

    The ankle is a unique modified saddle joint that, together with the subtalar joint, provides range of motion in several physical planes while maintaining stability. The ankle complex functions as a pivoting structure positioned to bear the entire weight of the body which leaves it vulnerable to injuries. Pure dislocation without associated fracture is rare; however, cases of isolated ankle dislocation without fracture have been reported. We report a case of a closed ankle dislocation without an associated fracture in a 17-year-old boy.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hammeschlag, S.B.; Hughes, S.; O'Reilly, G.V.

    Orbital blow-out fractures were experimentally created in eight human cadavers. Each orbit underwent conventional radiographic studies, complex motion tomography, and computed tomographic examinations. A comparison of the three modalities was made. Anatomical correlation was obtained by dissecting the orbits. The significance of medial-wall fractures and enophthalmos is discussed. Limitation of inferior rectus muscle mobility is thought to be a result of muscle kinking associated with orbital fat-pad prolapse at the fracture site, rather than muscle incarceration. Blow-out fractures should be evaluated by computed tomographic computer reformations in the oblique sagittal plane.

  8. Percolation Theory and Modern Hydraulic Fracturing

    NASA Astrophysics Data System (ADS)

    Norris, J. Q.; Turcotte, D. L.; Rundle, J. B.

    2015-12-01

    During the past few years, we have been developing a percolation model for fracking. This model provides a powerful tool for understanding the growth and properties of the complex fracture networks generated during a modern high volume hydraulic fracture stimulations of tight shale reservoirs. The model can also be used to understand the interaction between the growing fracture network and natural reservoir features such as joint sets and faults. Additionally, the model produces a power-law distribution of bursts which can easily be compared to observed microseismicity.

  9. Fracture surfaces of granular pastes.

    PubMed

    Mohamed Abdelhaye, Y O; Chaouche, M; Van Damme, H

    2013-11-01

    Granular pastes are dense dispersions of non-colloidal grains in a simple or a complex fluid. Typical examples are the coating, gluing or sealing mortars used in building applications. We study the cohesive rupture of thick mortar layers in a simple pulling test where the paste is initially confined between two flat surfaces. After hardening, the morphology of the fracture surfaces was investigated, using either the box counting method to analyze fracture profiles perpendicular to the mean fracture plane, or the slit-island method to analyze the islands obtained by cutting the fracture surfaces at different heights, parallel to the mean fracture plane. The fracture surfaces were shown to exhibit scaling properties over several decades. However, contrary to what has been observed in the brittle or ductile fracture of solid materials, the islands were shown to be mass fractals. This was related to the extensive plastic flow involved in the fracture process.

  10. Measurement of width and pressure in a propagating hydraulic fracture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warpinski, N.R.

    Measurements of width and pressure in a propagating hydraulic fracture have been made in tests conducted at the U.S. DOE's Nevada test site. This was accomplished by creating an ''instrumented fracture'' at a tunnel complex (at a depth of 1,400 ft (425 m)) where realistic insitu conditions prevail, particularly with respect to stress and geologic features such as natural fractures and material anisotropy. Analyses of these data show that the pressure drop along the fracture length is much larger than predicted by viscous theory, which currently is used in models. This apparently is caused by the tortuosity of the fracturemore » path, multiple fracture strands, roughness, and sharp turns (corners) in the flow path resulting from natural fractures and rock property variations. It suggests that fracture design models need to be updated to include a more realistic friction factor so that fracture lengths are not overestimated.« less

  11. Measurement of width and pressure in a propagating hydraulic fracture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warpinski, N.R.

    Measurements of width and pressure in a propagating hydraulic fracture have been made in tests conducted at DOE's Nevada Test Site. This was accomplished by creating an ''instrumented fracture'' at a tunnel complex (at a depth of 1400 ft) where realistic in-situ conditions prevail, particularly with respect to stress and geologic features such as natural fractures and material anisotropy. Analyses of these data show that the pressure drop along the fracture length is much larger than predicted by viscous theory and currently in use in models today. This is apparently due to the tortuosity of the fracture path, multiple fracturemore » strands, roughness and sharp turns (corners) in the flow path due to natural fractures and rock property variations. It suggests that fracture design models need to be updated to include a more realistic friction factor so that fracture lengths are not overestimated.« less

  12. Multi-scale modeling of microstructure dependent intergranular brittle fracture using a quantitative phase-field based method

    DOE PAGES

    Chakraborty, Pritam; Zhang, Yongfeng; Tonks, Michael R.

    2015-12-07

    In this study, the fracture behavior of brittle materials is strongly influenced by their underlying microstructure that needs explicit consideration for accurate prediction of fracture properties and the associated scatter. In this work, a hierarchical multi-scale approach is pursued to model microstructure sensitive brittle fracture. A quantitative phase-field based fracture model is utilized to capture the complex crack growth behavior in the microstructure and the related parameters are calibrated from lower length scale atomistic simulations instead of engineering scale experimental data. The workability of this approach is demonstrated by performing porosity dependent intergranular fracture simulations in UO 2 and comparingmore » the predictions with experiments.« less

  13. Multi-scale modeling of microstructure dependent intergranular brittle fracture using a quantitative phase-field based method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chakraborty, Pritam; Zhang, Yongfeng; Tonks, Michael R.

    In this study, the fracture behavior of brittle materials is strongly influenced by their underlying microstructure that needs explicit consideration for accurate prediction of fracture properties and the associated scatter. In this work, a hierarchical multi-scale approach is pursued to model microstructure sensitive brittle fracture. A quantitative phase-field based fracture model is utilized to capture the complex crack growth behavior in the microstructure and the related parameters are calibrated from lower length scale atomistic simulations instead of engineering scale experimental data. The workability of this approach is demonstrated by performing porosity dependent intergranular fracture simulations in UO 2 and comparingmore » the predictions with experiments.« less

  14. Discussion of examination of a cored hydraulic fracture in a deep gas well

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nolte, K.G.

    Warpinski et al. document information found from a core through a formation after a hydraulic fracture treatment. As they indicate, the core provides the first detailed evaluation of an actual propped hydraulic fracture away from the well and at a significant depth, and this evaluation leads to findings that deviate substantially from the assumptions incorporated into current fracturing models. In this discussion, a defense of current fracture design assumptions is developed. The affirmation of current assumptions, for general industry applications, is based on an assessment of the global impact of the local complexity found in the core. The assessment leadsmore » to recommendations for the evolution of fracture design practice.« less

  15. Principles of management and results of treating the fractured femur during and after total hip arthroplasty.

    PubMed

    Greidanus, Nelson V; Mitchell, Philip A; Masri, Bassam A; Garbuz, Donald S; Duncan, Clive P

    2003-01-01

    The management of fractures of the femur during and after total hip arthroplasty can be difficult, and treatment can be fraught with complications. The ideal scenario would be one in which these fractures are prevented. It is important that the surgeon has a through understanding of the principles of managing these fractures and has access to a variety of fixation and prosthetic devices and allograft bone when necessary in order to provide the best treatment. Because periprosthetic fractures range from the very simple (requiring no surgical intervention) to the complex (requiring major revision), a classification system of these fractures aids in understanding both the principles of management and results of treatment.

  16. [Treatment of complex tibial plateau fractures with bilateral locking plate and bone graft].

    PubMed

    Yan, Ying-Jie; Cheng, Zhan-Wei; Feng, Kai; Yan, Shao-Hua

    2012-07-01

    To explore the effective methods for the treatment of complex tibial plateau fractures. From May 2008 to April 2011, 28 patients with complex tibial plateau fractures were treated indirect reduction techniques, bilateral locking plate fixation combined with autologous bone grafts. There were 21 males and 7 females, with an average age of 43 years ranging from 21 to 65. There were 11 cases in Schatzker type V, 17 in VI. The effect was evaluated by Rasmussen standard on clinical and radiological. All patients were followed-up for 7 to 36 months (averaged of 21.5 months). Healing time of fracture was from 3 to 8 months (averaged 5.5 months). The results of Rasmussen scores in clinical was 4.50 +/- 1.32 in pain, 4.32 +/- 1.63 in walking ability, 4.07 +/- 1.34 in knee activity, 4.78 +/- 1.27 in stability of the knee, 4.85 +/- 1.12 in stretch knee; the results in radiation was 5.07 +/- 0.92 in articular surface collapse, 5.00 +/- 0.98 in platform widened, 5.14 +/- 0.85 in knee external varus. The effect result was excellent in 8 cases, good in 15, fair in 3 and poor in 2. The key for the treatment of complex tibial plateau fractures was to fully assess the damage as much as possible to protect the soft tissue, select the appropriate timing of surgery and surgical incision, application of indirect reduction techniques, limited incision and effective internal fixation to restore joint surface smooth and good limb alignment, early exercise, in order to achieve maximum recovery of joint function.

  17. Perioperative factors affecting the occurrence of acute complex regional pain syndrome following limb bone fracture surgery: data from the Japanese Diagnosis Procedure Combination database.

    PubMed

    Sumitani, Masahiko; Yasunaga, Hideo; Uchida, Kanji; Horiguchi, Hiromasa; Nakamura, Masaya; Ohe, Kazuhiko; Fushimi, Kiyohide; Matsuda, Shinya; Yamada, Yoshitsugu

    2014-07-01

    Complex regional pain syndrome (CRPS) describes a broad spectrum of symptoms that predominantly localize to the extremities. Although limb fracture is one of the most frequently reported triggering events, few large-scale studies have shown the occurrence of and factors associated with CRPS following limb fracture. This study aimed to show the occurrence and identify of those factors. Using the Japanese Diagnosis Procedure Combination database, we identified 39 patients diagnosed with CRPS immediately after open reduction and internal fixation (ORIF) for limb fracture from a cohort of 185 378 inpatients treated with ORIF between 1 July and 31 December of each year between 2007 and 2010. Patient and clinical characteristics such as age, gender, fracture site, duration of anaesthesia and use of regional anaesthesia were investigated by logistic regression analyses to examine associations between these factors and the in-hospital occurrence of CRPS after ORIF. The occurrence of CRPS was relatively high in fractures of the distal forearm, but low in fractures of the lower limb and in patients with multiple fractures. Generally females are considered to be at high risk of CRPS; however, we found a comparable number of male and female patients suffering from CRPS after ORIF for limb fracture. In terms of perioperative factors, a longer duration of anaesthesia, but not regional anaesthesia, was significantly associated with a higher incidence of CRPS. Although a limited number of CRPS patients were analysed in this study, reduced operative time might help to prevent the development of acute CRPS following limb fracture. © The Author 2013. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. [Operative treatment for complex tibial plateau fractures].

    PubMed

    Song, Qi-Zhi; Li, Tao

    2012-03-01

    To explore the surgical methods and clinical evaluation of complex tibial plateau fractures resulted from high-energy injuries. From March 2006 to May 2009,48 cases with complex tibial plateau fractures were treated with open reduction and plate fixation, including 37 males and 11 females, with an average age of 37 years (ranged from 18 to 63 years). According to Schatzker classification, 16 cases were type IV, 20 cases type V and 12 cases type VI. All patients were examined by X-ray flim and CT scan. The function of knee joint were evaluated according to postoperative follow-up X-ray and Knee Merchant Rating. Forty-eight patients were followed up with a mean time of 14 months. According to Knee Merchant Rating, 24 cases got excellent results, 16 cases good, 6 cases fair and 2 cases poor. Appropriate operation time, anatomical reduction, suitable bone graft and reasonable rehabilitation exercises can maximally recovery the function of knee joint.

  19. Investigation of the Effect of Cemented Fractures on Fracturing Network Propagation in Model Block with Discrete Orthogonal Fractures

    NASA Astrophysics Data System (ADS)

    Wang, Y.; Li, C. H.

    2017-07-01

    Researchers have recently realized that the natural fractures in shale reservoirs are often cemented or sealed with various minerals. However, the influence of cement characteristics of natural fracture on fracturing network propagation is still not well understood. In this work, laboratory-scaled experiments are proposed to prepare model blocks with discrete orthogonal fractures network with different strength of natural fracture, in order to reveal the influence of cemented natural fractures on the interactions between hydraulic fractures and natural fractures. A series of true triaxial hydraulic fracturing experiments were conducted to investigate the mechanism of hydraulic fracture initiation and propagation in model blocks with natural fractures of different cement strength. The results present different responses of interactions between hydraulic and natural fractures, which can be reflected on the pump pressure profiles and block failure morphology. For model blocks with fluctuated pump pressure curves, the communication degree of hydraulic and natural fractures is good, which is confirmed by a proposed new index of "P-SRV." The most significant finding is that too high and too low strength properties of cemented natural fracture are adverse to generate complex fracturing network. This work can help us better understand how cemented natural fractures affect the fracturing network propagation subsurface and give us reference to develop more accurate hydraulic fracturing models.

  20. Experimental Analysis of Hydraulic Fracture Growth and Acoustic Emission Response in a Layered Formation

    NASA Astrophysics Data System (ADS)

    Ning, Li; Shicheng, Zhang; Yushi, Zou; Xinfang, Ma; Shan, Wu; Yinuo, Zhang

    2018-04-01

    Microseismic/acoustic emission (AE) monitoring is an essential technology for understanding hydraulic fracture (HF) geometry and stimulated reservoir volume (SRV) during hydraulic fracturing in unconventional reservoirs. To investigate HF growth mechanisms and features of induced microseismic/AE events in a layered formation, laboratory fracturing experiments were performed on shale specimens (30 cm × 30 cm × 30 cm) with multiple bedding planes (BPs) under triaxial stresses. AE monitoring was used to reveal the spatial distribution and hypocenter mechanisms of AE events induced by rock failure. Computerized tomography scanning was used to observe the internal fracture geometry. Experimental results showed that the various HF geometries could be obviously distinguished based on injection pressure curves and AE responses. Fracture complexity was notably increased when vertically growing HFs connected with and opened more BPs. The formation of a complex fracture network was generally indicated by frequent fluctuations in injection pressure curves, intense AE activity, and three-dimensionally distributed AE events. Investigations of the hypocenter mechanisms revealed that shear failure/event dominated in shale specimens. Shear and tensile events were induced in hydraulically connected regions, and shear events also occurred around BPs that were not hydraulically connected. This led to an overestimation of HF height and SRV in layered formations based on the AE location results. The results also showed that variable injection rate and using plugging agent were conducive in promoting HF to penetrate through the weak and high-permeability BPs, thereby increasing the fracture height.

  1. Radiographic Outcomes of Volar Locked Plating for Distal Radius Fractures

    PubMed Central

    Mignemi, Megan E.; Byram, Ian R.; Wolfe, Carmen C.; Fan, Kang-Hsien; Koehler, Elizabeth A.; Block, John J.; Jordanov, Martin I.; Watson, Jeffry T.; Weikert, Douglas R.; Lee, Donald H.

    2013-01-01

    Purpose To assess the ability of volar locked plating to achieve and maintain normal radiographic parameters for articular stepoff, volar tilt, radial inclination, ulnar variance, and radial height in distal radius fractures. Methods We performed a retrospective review of 185 distal radius fractures that underwent volar locked plating with a single plate design over a 5-year period. We reviewed radiographs and recorded measurements for volar tilt, radial inclination, ulnar variance, radial height, and articular stepoff. We used logistic regression to determine the association between return to radiographic standard norms and fracture type. Results At the first and final postoperative follow-up visits, we observed articular congruence less than 2 mm in 92% of fractures at both times. Normal volar tilt (11°) was restored in 46% at the first follow-up and 48% at the final one. Radial inclination (22°) was achieved in 44% at the first follow-up and 43% at the final one, and ulnar variance (01 ± 2 mm) was achieved in 53% at the first follow-up and 53% at the final one. In addition, radial height (14 ± 1mm) was restored in 14% at the first follow-up and 12% at the final one. More complex, intra-articular fractures (AO class B and C and Frykman types 3, 4, 7, and 8) were less likely to be restored to normal radiographic parameters. However, because of the small sample size for some fracture types, it was difficult to discover significant associations between fracture type and radiographic outcome. Conclusions Volar locked plating for distal radius fractures achieved articular stepoff less than 2 mm in most fractures but only restored and maintained normal radiographic measurements for volar tilt, radial inclination, and ulnar variance in 50% of fractures. The ability of volar locked plating to restore and maintain ulnar variance and volar tilt decreased with more complex intra-articular fracture types. PMID:23218558

  2. Semi-analytical model of cross-borehole flow experiments for fractured medium characterization

    NASA Astrophysics Data System (ADS)

    Roubinet, D.; Irving, J.; Day-Lewis, F. D.

    2014-12-01

    The study of fractured rocks is extremely important in a wide variety of research fields where the fractures and faults can represent either rapid access to some resource of interest or potential pathways for the migration of contaminants in the subsurface. Identification of their presence and determination of their properties are critical and challenging tasks that have led to numerous fracture characterization methods. Among these methods, cross-borehole flowmeter analysis aims to evaluate fracture connections and hydraulic properties from vertical-flow-velocity measurements conducted in one or more observation boreholes under forced hydraulic conditions. Previous studies have demonstrated that analysis of these data can provide important information on fracture connectivity, transmissivity, and storativity. Estimating these properties requires the development of analytical and/or numerical modeling tools that are well adapted to the complexity of the problem. Quantitative analysis of cross-borehole flowmeter experiments, in particular, requires modeling formulations that: (i) can be adapted to a variety of fracture and experimental configurations; (ii) can take into account interactions between the boreholes because their radii of influence may overlap; and (iii) can be readily cast into an inversion framework that allows for not only the estimation of fracture hydraulic properties, but also an assessment of estimation error. To this end, we present a new semi-analytical formulation for cross-borehole flow in fractured media that links transient vertical-flow velocities measured in one or a series of observation wells during hydraulic forcing to the transmissivity and storativity of the fractures intersected by these wells. Our model addresses the above needs and provides a flexible and computationally efficient semi-analytical framework having strong potential for future adaptation to more complex configurations. The proposed modeling approach is demonstrated in the context of sensitivity analysis for a relatively simple two-fracture synthetic problem, as well as in the context of field-data analysis for fracture connectivity and estimation of corresponding hydraulic properties.

  3. The quality and readability of internet information regarding clavicle fractures.

    PubMed

    Zhang, Dafang; Schumacher, Charles; Harris, Mitchel Byron

    2016-03-01

    The internet has become a major source of health information for patients. However, there has been little scrutiny of health information available on the internet to the public. Our objectives were to evaluate the quality and readability of information available on the internet regarding clavicle fractures and whether they changed with academic affiliation of the website or with complexity of the search term. Through a prospective evaluation of 3 search engines using 3 different search terms of varying complexity ("broken collarbone," "collarbone fracture," and "clavicle fracture"), we evaluated 91 website hits for quality and readability. Websites were specifically analyzed by search term and by website type. Information quality was evaluated on a four-point scale, and information readability was assessed using the Flesch-Kincaid score for reading grade level. The average quality score for our website hits was low, and the average reading grade level was far above the recommended level. Academic websites offered significantly higher quality information, whereas commercial websites offered significantly lower quality information. The use of more complex search terms yielded information of higher reading grade level but not higher quality. Current internet information regarding clavicle fractures is of low quality and low readability. Higher quality information utilizing more accessible language on clavicle fractures is needed on the internet. It is important to be aware of the information accessible to patients prior to their presentation to our clinics. Patients should be advised to visit websites with academic affiliations and to avoid commercial websites. Copyright © 2015 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  4. Application of computer-aided three-dimensional skull model with rapid prototyping technique in repair of zygomatico-orbito-maxillary complex fracture.

    PubMed

    Li, Wei Zhong; Zhang, Mei Chao; Li, Shao Ping; Zhang, Lei Tao; Huang, Yu

    2009-06-01

    With the advent of CAD/CAM and rapid prototyping (RP), a technical revolution in oral and maxillofacial trauma was promoted to benefit treatment, repair of maxillofacial fractures and reconstruction of maxillofacial defects. For a patient with zygomatico-facial collapse deformity resulting from a zygomatico-orbito-maxillary complex (ZOMC) fracture, CT scan data were processed by using Mimics 10.0 for three-dimensional (3D) reconstruction. The reduction design was aided by 3D virtual imaging and the 3D skull model was reproduced using the RP technique. In line with the design by Mimics, presurgery was performed on the 3D skull model and the semi-coronal incision was taken for reduction of ZOMC fracture, based on the outcome from the presurgery. Postoperative CT and images revealed significantly modified zygomatic collapse and zygomatic arch rise and well-modified facial symmetry. The CAD/CAM and RP technique is a relatively useful tool that can assist surgeons with reconstruction of the maxillofacial skeleton, especially in repairs of ZOMC fracture.

  5. Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study.

    PubMed

    Chen, Pengbo; Lu, Hua; Shen, Hao; Wang, Wei; Ni, Binbin; Chen, Jishizhan

    2017-02-23

    Lateral column tibial plateau fracture fixation with a locking screw plate has higher mechanical stability than other fixation methods. The objectives of the present study were to introduce two newly designed locking anatomic plates for lateral tibial plateau fracture and to demonstrate their characteristics of the fixation complexes under the axial loads. Three different 3D finite element models of the lateral tibial plateau fracture with the bone plates were created. Various axial forces (100, 500, 1000, and 1500 N) were applied to simulate the axial compressive load on an adult knee during daily life. The equivalent maps of displacement and stress were output, and relative displacement was calculated along the fracture lines. The displacement and stresses in the fixation complexes increased with the axial force. The equivalent displacement or stress map of each fixation under different axial forces showed similar distributing characteristics. The motion characteristics of the three models differed, and the max-shear stress of trabecula increased with the axial load. These two novel plates could fix lateral tibial plateau fractures involving anterolateral and posterolateral fragments. Motions after open reduction and stable internal fixation should be advised to decrease the risk of trabecular microfracture. The relative displacement of the posterolateral fragments is different when using anterolateral plate and posterolateral plate, which should be considered in choosing the implants for different posterolateral plateau fractures.

  6. Periodic Hydraulic Testing for Discerning Fracture Network Connections

    NASA Astrophysics Data System (ADS)

    Becker, M.; Le Borgne, T.; Bour, O.; Guihéneuf, N.; Cole, M.

    2015-12-01

    Discrete fracture network (DFN) models often predict highly variable hydraulic connections between injection and pumping wells used for enhanced oil recovery, geothermal energy extraction, and groundwater remediation. Such connections can be difficult to verify in fractured rock systems because standard pumping or pulse interference tests interrogate too large a volume to pinpoint specific connections. Three field examples are presented in which periodic hydraulic tests were used to obtain information about hydraulic connectivity in fractured bedrock. The first site, a sandstone in New York State, involves only a single fracture at a scale of about 10 m. The second site, a granite in Brittany, France, involves a fracture network at about the same scale. The third site, a granite/schist in the U.S. State of New Hampshire, involves a complex network at scale of 30-60 m. In each case periodic testing provided an enhanced view of hydraulic connectivity over previous constant rate tests. Periodic testing is particularly adept at measuring hydraulic diffusivity, which is a more effective parameter than permeability for identify the complexity of flow pathways between measurement locations. Periodic tests were also conducted at multiple frequencies which provides a range in the radius of hydraulic penetration away from the oscillating well. By varying the radius of penetration, we attempt to interrogate the structure of the fracture network. Periodic tests, therefore, may be uniquely suited for verifying and/or calibrating DFN models.

  7. FRACTURING FLUID CHARACTERIZATION FACILITY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subhash Shah

    2000-08-01

    Hydraulic fracturing technology has been successfully applied for well stimulation of low and high permeability reservoirs for numerous years. Treatment optimization and improved economics have always been the key to the success and it is more so when the reservoirs under consideration are marginal. Fluids are widely used for the stimulation of wells. The Fracturing Fluid Characterization Facility (FFCF) has been established to provide the accurate prediction of the behavior of complex fracturing fluids under downhole conditions. The primary focus of the facility is to provide valuable insight into the various mechanisms that govern the flow of fracturing fluids andmore » slurries through hydraulically created fractures. During the time between September 30, 1992, and March 31, 2000, the research efforts were devoted to the areas of fluid rheology, proppant transport, proppant flowback, dynamic fluid loss, perforation pressure losses, and frictional pressure losses. In this regard, a unique above-the-ground fracture simulator was designed and constructed at the FFCF, labeled ''The High Pressure Simulator'' (HPS). The FFCF is now available to industry for characterizing and understanding the behavior of complex fluid systems. To better reflect and encompass the broad spectrum of the petroleum industry, the FFCF now operates under a new name of ''The Well Construction Technology Center'' (WCTC). This report documents the summary of the activities performed during 1992-2000 at the FFCF.« less

  8. Biomechanical Tolerance of Calcaneal Fractures

    PubMed Central

    Yoganandan, Narayan; Pintar, Frank A.; Gennarelli, Thomas A.; Seipel, Robert; Marks, Richard

    1999-01-01

    Biomechanical studies have been conducted in the past to understand the mechanisms of injury to the foot-ankle complex. However, statistically based tolerance criteria for calcaneal complex injuries are lacking. Consequently, this research was designed to derive a probability distribution that represents human calcaneal tolerance under impact loading such as those encountered in vehicular collisions. Information for deriving the distribution was obtained by experiments on unembalmed human cadaver lower extremities. Briefly, the protocol included the following. The knee joint was disarticulated such that the entire lower extremity distal to the knee joint remained intact. The proximal tibia was fixed in polymethylmethacrylate. The specimens were aligned and impact loading was applied using mini-sled pendulum equipment. The pendulum impactor dynamically loaded the plantar aspect of the foot once. Following the test, specimens were palpated and radiographs in multiple planes were obtained. Injuries were classified into no fracture, and extra-and intra-articular fractures of the calcaneus. There were 14 cases of no injury and 12 cases of calcaneal fracture. The fracture forces (mean: 7802 N) were significantly different (p<0.01) from the forces in the no injury (mean: 4144 N) group. The probability of calcaneal fracture determined using logistic regression indicated that a force of 6.2 kN corresponds to 50 percent probability of calcaneal fracture. The derived probability distribution is useful in the design of dummies and vehicular surfaces.

  9. The influence of a reverse-reactivated normal fault on natural fracture geometries and relative chronologies at Castle Cove, Otway Basin

    NASA Astrophysics Data System (ADS)

    Debenham, Natalie; King, Rosalind C.; Holford, Simon P.

    2018-07-01

    Despite the ubiquity of normal faults that have undergone compressional inversion, documentation of the structural history of natural fractures around these structures is limited. In this paper, we investigate the geometries and relative chronologies of natural fractures adjacent to a reverse-reactivated normal fault, the Castle Cove Fault in the Otway Basin, southeast Australia. Local variations in strain resulted in greater deformation within the fault damage zone closer to the fault. Structural mapping within the damage zone reveals a complex tectonic history recording both regional and local perturbations in stress and a total of 11 fracture sets were identified, with three sets geometrically related to the Castle Cove Fault. The remaining fracture sets formed in response to local stresses at Castle Cove. Rifting in the late Cretaceous resulted in normal movement of the Castle Cove Fault and associated rollover folding, and the formation of the largest fracture set. Reverse-reactivation of the fault and associated anticlinal folding occurred during late Miocene to Pliocene compression. Rollover folding may have provided structural traps if seals were not breached by fractures, however anticlinal folding likely post-dated the main episodes of hydrocarbon generation and migration in the region. This study highlights the need to conduct careful reconstruction of the structural histories of fault zones that experienced complex reactivation histories when attempting to define off-fault fluid flow properties.

  10. [Arthroscopy-guided fracture management. Ankle joint and calcaneus].

    PubMed

    Schoepp, C; Rixen, D

    2013-04-01

    Arthroscopic fracture management of the ankle and calcaneus requires a differentiated approach. The aim is to minimize surgical soft tissue damage and to visualize anatomical fracture reduction arthroscopically. Moreover, additional cartilage damage can be detected and treated. The arthroscopic approach is limited by deep impressions of the joint surface needing cancellous bone grafting, by multiple fracture lines on the articular side and by high-grade soft tissue damage. An alternative to the minimally invasive arthroscopic approach is open arthroscopic reduction in conventional osteosynthesis. This facilitates correct assessment of surgical reduction of complex calcaneal fractures, otherwise remaining non-anatomical reduction might not be fluoroscopically detected during surgery.

  11. Role for Primary Repair of Deltoid Ligament Complex in Ankle Fractures.

    PubMed

    Rigby, Ryan B; Scott, Ryan T

    2018-04-01

    Acute deltoid injuries may occur with ankle fractures. They are often left to heal without repair, possibly leading to chronic medial ankle instability. Stress radiographs identify the need for surgical repair of fractures or soft tissue damage. Gravity stress views have benefits over manually stressing the ankle. MRI can explore the extent of medial soft tissue injuries. Arthroscopy can evaluate and potentially treat deltoid injuries. Interposition of the deltoid may preclude adequate fracture reduction. Except with deltoid tear, fractures should be reduced and fixated, then the deltoid assessed. With persistent instability, primary repair may prevent long-term sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Biomechanical concepts applicable to minimally invasive fracture repair in small animals.

    PubMed

    Chao, Peini; Lewis, Daniel D; Kowaleski, Michael P; Pozzi, Antonio

    2012-09-01

    Understanding the basic biomechanical principles of surgical stabilization of fractures is essential for developing an appropriate preoperative plan as well as making prudent intraoperative decisions. This article aims to provide basic biomechanical knowledge essential to the understanding of the complex interaction between the mechanics and biology of fracture healing. The type of healing and the outcome can be influenced by several mechanical factors, which depend on the interaction between bone and implant. The surgeon should understand the mechanical principles of fracture fixation and be able to choose the best type of fixation for each specific fracture. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Complications in Pediatric Facial Fractures

    PubMed Central

    Chao, Mimi T.; Losee, Joseph E.

    2009-01-01

    Despite recent advances in the diagnosis, treatment, and prevention of pediatric facial fractures, little has been published on the complications of these fractures. The existing literature is highly variable regarding both the definition and the reporting of adverse events. Although the incidence of pediatric facial fractures is relative low, they are strongly associated with other serious injuries. Both the fractures and their treatment may have long-term consequence on growth and development of the immature face. This article is a selective review of the literature on facial fracture complications with special emphasis on the complications unique to pediatric patients. We also present our classification system to evaluate adverse outcomes associated with pediatric facial fractures. Prospective, long-term studies are needed to fully understand and appreciate the complexity of treating children with facial fractures and determining the true incidence, subsequent growth, and nature of their complications. PMID:22110803

  14. Laparoscopic omentoplasty to support anastomotic urethroplasty in complex and redo pelvic fracture urethral defects.

    PubMed

    Kulkarni, Sanjay B; Barbagli, Guido; Joshi, Pankaj M; Hunter, Craig; Shahrour, Walid; Kulkarni, Jyotsna; Sansalone, Salvatore; Lazzeri, Massimo

    2015-05-01

    To test the hypothesis that a new surgical technique using elaborated perineal anastomotic urethroplasty combined with laparoscopic omentoplasty for patients with complex and prior failed pelvic fracture urethral defect repair was feasible, safe, and effective. We performed a prospective, observational, stage 2a study to observe treatment outcomes of combined perineal and laparoscopic approach for urethroplasty in patients with pelvic fracture urethral defect at a single center in Pune, India, between January 2012 and February 2013. Complex and redo patients with pelvic fracture urethral defect occurring after pelvic fracture urethral injury were included in the study. Anterior urethral strictures were excluded. The primary study outcome was the success rate of the surgical technique, and the secondary outcome was to evaluate feasibility and safety of the procedure. The clinical outcome was considered a failure when any postoperative instrumentation was needed. Fifteen male patients with a median age of 19 years were included in the study. Seven patients were adolescents (12-18 years) and 8 patients (53.3%) were adults (19-49 years). The mean number of prior urethroplasties was 1.8 (range, 1-3). All patients underwent elaborated bulbomembranous anastomosis using a perineal approach with inferior pubectomy combined with laparoscopic mobilization of the omentum into the perineum to envelope the anastomosis and to fill the perineal dead space. Of 15 patients, 14 (93.3%) were successful and 1 (6.6%) failed. One adolescent boy 14 years old developed a recurrent stricture 2 months after the procedure and was managed using internal urethrotomy. Median follow-up was 18 months (range, 13-24 months). Combining a laparoscopic omentoplasty to a membranobulbar anastomosis for complex and redo pelvic fracture urethral injury is successful, feasible, safe, and with minimal additional morbidity to the patient. The technique has the advantage of a perineal incision and the ability to use the omentum to support the anastomosis. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Physical simulation study on the hydraulic fracture propagation of coalbed methane well

    NASA Astrophysics Data System (ADS)

    Wu, Caifang; Zhang, Xiaoyang; Wang, Meng; Zhou, Longgang; Jiang, Wei

    2018-03-01

    As the most widely used technique to modify reservoirs in the exploitation of unconventional natural gas, hydraulic fracturing could effectively raise the production of CBM wells. To study the propagation rules of hydraulic fractures, analyze the fracture morphology, and obtain the controlling factors, a physical simulation experiment was conducted with a tri-axial hydraulic fracturing test system. In this experiment, the fracturing sample - including the roof, the floor, and the surrounding rock - was prepared from coal and similar materials, and the whole fracturing process was monitored by an acoustic emission instrument. The results demonstrated that the number of hydraulic fractures in coal is considerably higher than that observed in other parts, and the fracture morphology was complex. Vertical fractures were interwoven with horizontal fractures, forming a connected network. With the injection of fracturing fluid, a new hydraulic fracture was produced and it extended along the preexisting fractures. The fracture propagation was a discontinuous, dynamic process. Furthermore, in-situ stress plays a key role in fracture propagation, causing the fractures to extend in a direction perpendicular to the minimum principal stress. To a certain extent, the different mechanical properties of the coal and the other components inhibited the vertical propagation of hydraulic fractures. Nonetheless, the vertical stress and the interfacial property are the major factors to influence the formation of the "T" shaped and "工" shaped fractures.

  16. Clinical, retrospective case-control study on the mechanics of obstacle in mouth opening and malocclusion in patients with maxillofacial fractures.

    PubMed

    Zhou, Hai-Hua; Lv, Kun; Yang, Rong-Tao; Li, Zhi; Yang, Xue-Wen; Li, Zu-Bing

    2018-05-16

    This study aims to identify and distinguish various factors that may influence the clinical symptoms (limited mouth opening and malocclusion) in patients with maxillofacial fractures. From January 2000 to December 2009, 963 patients with maxillofacial fractures were enrolled in this statistical study to aid in evaluating the association between various risk factors and clinical symptoms. Patients with fractured posterior mandibles tended to experience serious limitation in mouth opening. Patients who sustained coronoid fractures have the highest risk of serious limitation in mouth opening (OR = 9.849), followed by arch fractures, maxilla fractures, condylar fractures, zygomatic complex fractures and symphysis fractures. Meanwhile, the combined fracture of zygomatic arch and condylar process results in normal or mild mouth opening. High risks of sustaining malocclusion are preceded by the fracture of nasal bone (OR = 3.067), mandible, condylar neck/base, combined fracture of zygomatic arch and condylar process, mandibular body, bilateral condylar, dental trauma, mandibular ramus, symphysis, mandibular angle and mid-facial. Patients who experienced serious limitation in mouth opening are treated with surgery more frequently (OR = 2.118). No relationship exists between the treatment options and the patients with malocclusion.

  17. Initiation and propagation of mixed mode fractures in granite and sandstone

    NASA Astrophysics Data System (ADS)

    Rück, Marc; Rahner, Roman; Sone, Hiroki; Dresen, Georg

    2017-10-01

    We investigate mixed mode fracture initiation and propagation in experimentally deformed granite and sandstone. We performed a series of asymmetric loading tests to induce fractures in cylindrical specimens at confining pressures up to 20 MPa. Loading was controlled using acoustic emission (AE) feedback control, which allows studying quasi-static fracture propagation for several hours. Location of acoustic emissions reveals distinct differences in spatial-temporal fracture evolution between granite and sandstone samples. Before reaching peak stress in experiments performed on granite, axial fractures initiate first at the edge of the indenter and then propagate through the entire sample. Secondary inclined fractures develop during softening of the sample. In sandstone, inclined shear fractures nucleate at peak stress and propagate through the specimen. AE source type analysis shows complex fracturing in both materials with pore collapse contributing significantly to fracture growth in sandstone samples. We compare the experimental results with numerical models to analyze stress distribution and energy release rate per unit crack surface area in the samples at different stages during fracture growth. We thereby show that for both rock types the energy release rate increases approximately linearly during fracture propagation. The study illuminates how different material properties modify fracture initiation direction under similar loading conditions.

  18. Fractal vein distributions within a fault-fracture mesh in an exhumed accretionary mélange, Chrystalls Beach Complex, New Zealand

    NASA Astrophysics Data System (ADS)

    Fagereng, Åke

    2011-05-01

    A well developed fault-fracture mesh is observed in the Chrystalls Beach Complex, an accretionary mélange within the Otago Schist on the South Island of New Zealand. In this study, an analysis of vein thicknesses and clustering of veins is presented. Both shear and extension veins have a power-law thickness distribution. Measures of vein spacing best fit a power-law distribution, but a small data set limits this interpretation to a small fractal range. Vein clustering varies from random to moderately clustered between outcrops, and is the greatest where a large proportion of relatively competent blocks occurs within the mélange. Fractures are distributed within the mélange matrix, and this localized deformation requires heterogeneity in rheology and/or fluid pressure distribution, whereas pervasive, distributed deformation occurs in relatively homogeneous rock. The overall trend of this deformation being mainly accommodated by thin veins required that new fractures formed preferentially over refracturing existing veins, which highlights the distributed nature of deformation within a fault-fracture mesh. The predominance of new fractures may result from vein material being stronger than the cleaved wall rock, such that wall rock failure occurred instead of reopening of pre-existing shear and extension veins.

  19. Theoretical Analysis of the Mechanism of Fracture Network Propagation with Stimulated Reservoir Volume (SRV) Fracturing in Tight Oil Reservoirs.

    PubMed

    Su, Yuliang; Ren, Long; Meng, Fankun; Xu, Chen; Wang, Wendong

    2015-01-01

    Stimulated reservoir volume (SRV) fracturing in tight oil reservoirs often induces complex fracture-network growth, which has a fundamentally different formation mechanism from traditional planar bi-winged fracturing. To reveal the mechanism of fracture network propagation, this paper employs a modified displacement discontinuity method (DDM), mechanical mechanism analysis and initiation and propagation criteria for the theoretical model of fracture network propagation and its derivation. A reasonable solution of the theoretical model for a tight oil reservoir is obtained and verified by a numerical discrete method. Through theoretical calculation and computer programming, the variation rules of formation stress fields, hydraulic fracture propagation patterns (FPP) and branch fracture propagation angles and pressures are analyzed. The results show that during the process of fracture propagation, the initial orientation of the principal stress deflects, and the stress fields at the fracture tips change dramatically in the region surrounding the fracture. Whether the ideal fracture network can be produced depends on the geological conditions and on the engineering treatments. This study has both theoretical significance and practical application value by contributing to a better understanding of fracture network propagation mechanisms in unconventional oil/gas reservoirs and to the improvement of the science and design efficiency of reservoir fracturing.

  20. Theoretical Analysis of the Mechanism of Fracture Network Propagation with Stimulated Reservoir Volume (SRV) Fracturing in Tight Oil Reservoirs

    PubMed Central

    Su, Yuliang; Ren, Long; Meng, Fankun; Xu, Chen; Wang, Wendong

    2015-01-01

    Stimulated reservoir volume (SRV) fracturing in tight oil reservoirs often induces complex fracture-network growth, which has a fundamentally different formation mechanism from traditional planar bi-winged fracturing. To reveal the mechanism of fracture network propagation, this paper employs a modified displacement discontinuity method (DDM), mechanical mechanism analysis and initiation and propagation criteria for the theoretical model of fracture network propagation and its derivation. A reasonable solution of the theoretical model for a tight oil reservoir is obtained and verified by a numerical discrete method. Through theoretical calculation and computer programming, the variation rules of formation stress fields, hydraulic fracture propagation patterns (FPP) and branch fracture propagation angles and pressures are analyzed. The results show that during the process of fracture propagation, the initial orientation of the principal stress deflects, and the stress fields at the fracture tips change dramatically in the region surrounding the fracture. Whether the ideal fracture network can be produced depends on the geological conditions and on the engineering treatments. This study has both theoretical significance and practical application value by contributing to a better understanding of fracture network propagation mechanisms in unconventional oil/gas reservoirs and to the improvement of the science and design efficiency of reservoir fracturing. PMID:25966285

  1. Sacral Fractures and Associated Injuries

    PubMed Central

    Kurd, Mark F.; Schroeder, Gregory D.; Kepler, Christopher K.; Krieg, James C.; Holstein, Jörg H.; Bellabarba, Carlo; Firoozabadi, Reza; Oner, F. Cumhur; Kandziora, Frank; Dvorak, Marcel F.; Kleweno, Conor P.; Vialle, Luiz R.; Rajasekaran, S.; Schnake, Klause J.; Vaccaro, Alexander R.

    2017-01-01

    Study Design: Literature review. Objective: The aim of this review is to describe the injuries associated with sacral fractures and to analyze their impact on patient outcome. Methods: A comprehensive narrative review of the literature was performed to identify the injuries associated with sacral fractures. Results: Sacral fractures are uncommon injuries that result from high-energy trauma, and that, due to their rarity, are frequently underdiagnosed and mistreated. Only 5% of sacral fractures occur in isolation. Injuries most often associated with sacral fractures include neurologic injuries (present in up to 50% of sacral fractures), pelvic ring disruptions, hip and lumbar spine fractures, active pelvic/ abdominal bleeding and the presence of an open fracture or significant soft tissue injury. Diagnosis of pelvic ring fractures and fractures extending to the lumbar spine are key factors for the appropriate management of sacral fractures. Importantly, associated systemic (cranial, thoracic, and abdominopelvic) or musculoskeletal injuries should be promptly assessed and addressed. These associated injuries often dictate the management and eventual outcome of sacral fractures and, therefore, any treatment algorithm should take them into consideration. Conclusions: Sacral fractures are complex in nature and often associated with other often-missed injuries. This review summarizes the most relevant associated injuries in sacral fractures and discusses on their appropriate management. PMID:28989838

  2. Physical Properties of Fractured Porous Media

    NASA Astrophysics Data System (ADS)

    Mohammed, T. E.; Schmitt, D. R.

    2015-12-01

    The effect of fractures on the physical properties of porous media is of considerable interest to oil and gas exploration as well as enhanced geothermal systems and carbon capture and storage. This work represents an attempt to study the effect fractures have on multiple physical properties of rocks. An experimental technique to make simultaneous electric and ultrasonic measurements on cylindrical core plugs is developed. Aluminum end caps are mounted with ultrasonic transducers to transmit pules along the axis of the cylinder while non-polarizing electrodes are mounted on the sides of the core to make complex conductivity measurements perpendicular to the cylinder axis. Electrical measurements are made by applying a sinusoidal voltage across the measurement circuit that consist of a resister and the sample in series. The magnitude and phase of the signal across the sample is recorded relative to the input signal across a range of frequencies. Synthetic rock analogs are constructed using sintered glass beads with fractures imbedded in them. The fracture location, size and orientation are controlled and each fractured specimen has an unfractured counterpart. Porosity, Permeability, electrical conductivity and ultrasonic velocity measurements are conducted on each sample with the complex electrical conductivities recorded at frequencies from 10hz to 1 Mhz. These measurements allow us to examine the changes induced by these mesoscale fractures on the embedding porous medium. Of particular interest is the effect of fracture orientation on electrical conductivity of the rock. Seismic anisotropy caused by fractures is a well understood phenomenon with many rock physics models dedicated to its understanding. The effect of fractures on electrical conductivity is less well understood with electrical anisotropy scarcely investigated in the literature. None the less, using electrical conductivity to characterize fractures can add an extra constraint to characterization based on seismic response. As well, the formal similarity between electrical conductivity and permeability can be utilized to help optimize injection and production strategies.

  3. Reactive solute transport in an asymmetrical fracture-rock matrix system

    NASA Astrophysics Data System (ADS)

    Zhou, Renjie; Zhan, Hongbin

    2018-02-01

    The understanding of reactive solute transport in a single fracture-rock matrix system is the foundation of studying transport behavior in the complex fractured porous media. When transport properties are asymmetrically distributed in the adjacent rock matrixes, reactive solute transport has to be considered as a coupled three-domain problem, which is more complex than the symmetric case with identical transport properties in the adjacent rock matrixes. This study deals with the transport problem in a single fracture-rock matrix system with asymmetrical distribution of transport properties in the rock matrixes. Mathematical models are developed for such a problem under the first-type and the third-type boundary conditions to analyze the spatio-temporal concentration and mass distribution in the fracture and rock matrix with the help of Laplace transform technique and de Hoog numerical inverse Laplace algorithm. The newly acquired solutions are then tested extensively against previous analytical and numerical solutions and are proven to be robust and accurate. Furthermore, a water flushing phase is imposed on the left boundary of system after a certain time. The diffusive mass exchange along the fracture/rock matrixes interfaces and the relative masses stored in each of three domains (fracture, upper rock matrix, and lower rock matrix) after the water flushing provide great insights of transport with asymmetric distribution of transport properties. This study has the following findings: 1) Asymmetric distribution of transport properties imposes greater controls on solute transport in the rock matrixes. However, transport in the fracture is mildly influenced. 2) The mass stored in the fracture responses quickly to water flushing, while the mass stored in the rock matrix is much less sensitive to the water flushing. 3) The diffusive mass exchange during the water flushing phase has similar patterns under symmetric and asymmetric cases. 4) The characteristic distance which refers to the zero diffusion between the fracture and the rock matrix during the water flushing phase is closely associated with dispersive process in the fracture.

  4. Rock Fracture Toughness Study Under Mixed Mode I/III Loading

    NASA Astrophysics Data System (ADS)

    Aliha, M. R. M.; Bahmani, A.

    2017-07-01

    Fracture growth in underground rock structures occurs under complex stress states, which typically include the in- and out-of-plane sliding deformation of jointed rock masses before catastrophic failure. However, the lack of a comprehensive theoretical and experimental fracture toughness study for rocks under contributions of out-of plane deformations (i.e. mode III) is one of the shortcomings of this field. Therefore, in this research the mixed mode I/III fracture toughness of a typical rock material is investigated experimentally by means of a novel cracked disc specimen subjected to bend loading. It was shown that the specimen can provide full combinations of modes I and III and consequently a complete set of mixed mode I/III fracture toughness data were determined for the tested marble rock. By moving from pure mode I towards pure mode III, fracture load was increased; however, the corresponding fracture toughness value became smaller. The obtained experimental fracture toughness results were finally predicted using theoretical and empirical fracture models.

  5. Early Tibiotalocalcaneal Arthrodesis Intramedullary Nail for Treatment of a Complex Tibial Pilon Fracture (AO/OTA 43-C).

    PubMed

    Hsu, Andrew R; Szatkowski, Jan P

    2015-06-01

    Management of severely comminuted, complete articular tibial pilon fractures (AO/OTA 43-C) remains a challenge, with few treatment options providing good clinical outcomes. Open reduction and internal fixation of the tibial plafond, tibiotalar arthrodesis, and salvage hindfoot reconstruction procedures are all associated with surgical complications and functional limitations. In this report, we present a case of a complex pilon fracture in a patient with multiple medical comorbidities and socioeconomic disadvantages that was successfully and acutely treated with a retrograde tibiotalocalcaneal hindfoot arthrodesis nail. At final follow-up examination, the patient had decreased pain, a stable plantigrade foot, and could ambulate with normal shoes without any assistive devices. Therapeutic, Level IV: Case series. © 2014 The Author(s).

  6. FACTORS ASSOCIATED WITH COMPLEX REGIONAL PAIN SYNDROME IN SURGICALLY TREATED DISTAL RADIUS FRACTURE.

    PubMed

    Ortiz-Romero, Joel; Bermudez-Soto, Ignacio; Torres-González, Rubén; Espinoza-Choque, Fernando; Zazueta-Hernandez, Jesús Abraham; Perez-Atanasio, José Manuel

    2017-01-01

    The aim of this study was to identify factors associated with developing complex regional pain syndrome (CRPS) after surgical treatment for distal radius fracture (DRF). This case-control study analyzed patients seen from January 2014 to January 2016. Results: In our sample of 249 patients, 4% developed CRPS. Associated factors were economic compensation via work disability (odds ratio [OR] 14.3), age (OR 9.38), associated fracture (OR 12.94), and level of impact (OR 6.46), as well as psychiatric history (OR 7.21). Economically-productive aged patients with a history of high-impact trauma and patients with a history of psychiatric disorders have greater risk of developing CRPS after DRF. Level of Evidence III, Case-Control Study.

  7. Le Fort Fractures: A Collective Review

    PubMed Central

    Phillips, Bradley J.; Turco, Lauren M.

    2017-01-01

    Le Fort fractures constitute a pattern of complex facial injury that occurs secondary to blunt facial trauma.  The most common mechanisms of injury for these fractures, which are frequently associated with drug and alcohol use, include motor vehicle collisions, assault, and falls. A thorough search of the world’s literature following PRISMA guidelines was conducted through PubMed and EBSCO databases. Search terms included “Le Fort fracture”, “facial”, “craniofacial”, and “intracranial.”  Articles were selected based on relevance and examined regarding etiology, epidemiology, diagnosis, treatment, complications, and outcomes in adults. The analyzed studies were published between 1980 and 2016. Initial data search yielded 186 results. The search was narrowed to exclude articles lacking in specificity for Le Fort fractures.  Fifty-one articles were selected, the majority of which were large case studies, and collectively reported that Le Fort fractures are most commonly due to high-velocity MVC and that the severity of fracture type sustained occurred with increasing frequency.  It was also found that there is a general lack of published Level I, Level II, and Level III studies regarding Le Fort fracture management, surgical management, and outcomes. The limitation of this study, similar to all PRISMA-guided review articles, is the dependence on previously published research and availability of references as outlined in our methodology. While mortality rates for Le Fort fractures are low, these complex injuries seldom occur in isolation and are associated with other severe injuries to the head and neck. Quick and accurate diagnosis of Le Fort fractures and associated injuries is crucial to the successful management of blunt head trauma. PMID:29177168

  8. Post-junctional facilitation of substance P signaling in a tibia fracture rat model of complex regional pain syndrome type I

    PubMed Central

    Wei, Tzuping; Li, Wen-wu; Guo, Tian-Zhi; Zhao, Rong; Wang, Liping; Clark, David J; Oaklander, Ann Louise; Schmelz, Martin; Kingery, Wade S.

    2009-01-01

    Tibia fracture in rats evokes nociceptive, vascular, and bone changes resembling complex regional pain syndrome (CRPS). Substance P (SP) signaling contributes to the hindpaw warmth, increased vascular permeability, and edema observed in this model, suggesting that neurogenic inflammatory responses could be enhanced after fracture. Four weeks after tibia fracture we measured SP and calcitonin gene-related peptide (CGRP) protein levels in the sciatic nerve and serum. Hindpaw skin extravasation responses and SP receptor (NK1), CGRP receptor (calcitonin receptor-like receptor, CRLR) and neutral endopeptidase (NEP) protein levels were also determined. Gene expression levels of these peptides, receptors, and peptidase were examined in the DRG and skin. Spontaneous and intravenous SP-evoked extravasation responses were increased ipsilateral, but not contralateral to the fracture. Fracture increased SP and CGRP gene expression in the ipsilateral L4,L5 DRG and neuropeptide protein levels in the sciatic nerve and in serum, but had no effect on electrically-evoked SP and CGRP release. NK1 receptor expression was increased in the ipsilateral hindpaw skin keratinocytes and endothelial cells after injury, but CRLR and NEP expression were unchanged. Fracture also increased epidermal thickness, but had no effect on epidermal skin neurite counts. These results demonstrate that spontaneous and intravenous SP-evoked extravasation responses are enhanced in the ipsilateral hindlimb after fracture and that fracture chronically increases the expression of endothelial and keratinocyte NK1 receptors in the injured limb. We postulate that SP activation of these up-regulated NK1 receptors results in skin warmth, protein leakage, edema, and keratinocyte proliferation in the injured limb. PMID:19464118

  9. Post-junctional facilitation of Substance P signaling in a tibia fracture rat model of complex regional pain syndrome type I.

    PubMed

    Wei, Tzuping; Li, Wen-Wu; Guo, Tian-Zhi; Zhao, Rong; Wang, Liping; Clark, David J; Oaklander, Anne Louise; Schmelz, Martin; Kingery, Wade S

    2009-08-01

    Tibia fracture in rats evokes nociceptive, vascular, and bone changes resembling complex regional pain syndrome (CRPS). Substance P (SP) signaling contributes to the hindpaw warmth, increased vascular permeability, and edema observed in this model, suggesting that neurogenic inflammatory responses could be enhanced after fracture. Four weeks after tibia fracture we measured SP and calcitonin gene-related peptide (CGRP) protein levels in the sciatic nerve and serum. Hindpaw skin extravasation responses and SP receptor (NK1), CGRP receptor (calcitonin receptor-like receptor, CRLR) and neutral endopeptidase (NEP) protein levels were also determined. Gene expression levels of these peptides, receptors, and peptidase were examined in the DRG and skin. Spontaneous and intravenous SP-evoked extravasation responses were increased ipsilateral, but not contralateral to the fracture. Fracture increased SP and CGRP gene expression in the ipsilateral L4,L5 DRG and neuropeptide protein levels in the sciatic nerve and in serum, but had no effect on electrically evoked SP and CGRP release. NK1 receptor expression was increased in the ipsilateral hindpaw skin keratinocytes and endothelial cells after injury, but CRLR and NEP expression were unchanged. Fracture also increased epidermal thickness, but had no effect on epidermal skin neurite counts. These results demonstrate that spontaneous and intravenous SP-evoked extravasation responses are enhanced in the ipsilateral hindlimb after fracture and that fracture chronically increases the expression of endothelial and keratinocyte NK1 receptors in the injured limb. We postulate that SP activation of these up-regulated NK1 receptors results in skin warmth, protein leakage, edema, and keratinocyte proliferation in the injured limb.

  10. Modeling folding related multi-scale deformation of sedimentary rock using ALSM and fracture characterization at Raplee Ridge, UT

    NASA Astrophysics Data System (ADS)

    Mynatt, I.; Hilley, G. E.; Pollard, D. D.

    2006-12-01

    Understanding and predicting the characteristics of folding induced fracturing is an important and intriguing structural problem. Folded sequences of sedimentary rock at depth are common traps for hydrocarbons and water and fractures can strongly effect (both positively and negatively) this trapping capability. For these reasons fold-fracture relationships are well studied, but due to the complex interactions between the remote tectonic stress, rheologic properties, underlying fault geometry and slip, and pre-existing fractures, fracture characteristics can vary greatly from fold to fold. Additionally, examination of the relationships between fundamental characteristics such as fold geometry and fracture density are difficult even in thoroughly studied producing fields as measurements of fold shape are hampered by the low resolution of seismic surveying and measurements of fractures are limited to sparse well-bore locations. Due to the complexity of the system, the limitations of available data and small number of detailed case studies, prediction of fracture characteristics, e.g. the distribution of fracture density, are often difficult to make for a particular fold. We suggest a combination of mechanical and numerical modeling and analysis combined with detailed field mapping can lead to important insights into fold-fracture relationships. We develop methods to quantify both fold geometry and fracture characteristics, and summarize their relationships for an exhumed analogue reservoir case study. The field area is Raplee Monocline, a Laramide aged, N-S oriented, ~14-km long fold exposed in the Monument Upwarp of south-eastern Utah and part of the larger Colorado Plateau geologic province. The investigation involves three distinct parts: 1) Field based characterization and mapping of the fractures on and near the fold; 2) Development of accurate models of the fold geometry using high resolution data including ~3.5x107 x, y, z topographic points collected using Airborne Laser Swath Mapping (ALSM); and 3) Analysis of the fold shape and fracture patterns using the concepts of differential geometry and fracture mechanics. Field documentation of fracture characteristics enables the classification of distinct pre- and syn- folding fracture sets and the development of conceptual models of multiple stages of fracture evolution. Numerical algorithms, visual methods and field mapping techniques are used to extract the geometry of specific stratigraphic bedding surfaces and interpolate fold geometry between topographic exposures, thereby creating models of the fold geometry at several stratigraphic levels. Geometric characteristics of the fold models, such as magnitudes and directions of maximum and minimum normal curvature and fold limb dip, are compared to the observed fracture characteristics to identify the following relationships: 1) Initiation of folding related fractures at ten degrees of limb dip and increasing fracture density with increasing dip and 2) No correlation between absolute maximum fold curvature and fracture density.

  11. Wrist fractures and their impact in daily living functionality on elderly people: a prospective cohort study.

    PubMed

    Vergara, Itziar; Vrotsou, Kalliopi; Orive, Miren; Garcia-Gutierrez, Susana; Gonzalez, Nerea; Las Hayas, Carlota; Quintana, Jose M

    2016-01-14

    Wrist fractures are the most common arm fractures in older adults. The impact of wrist fractures on daily functionality has been less studied than that of other types and so, less is known about the complexity of factors related to the functional impact of these fractures. This study is aimed to assess the role of individual and health care factors and its association with daily living functional changes after a wrist fracture. A prospective cohort of patients aged 65 or more, affected by a fracture due to a fall, was conducted. These patients were identified at the emergency rooms of the six participating hospitals. As independent factors, the following were studied: socio-demographic data, characteristics of the fracture, health-related quality of life, wrist function and provided treatment. The main outcome was functional status measured by the Barthel Index for daily living basic activities and the Lawton Instrumental Activities of Daily Living (IADL) Scale for daily living instrumental activities. Data were collected at baseline just after the fall and after six months of follow-up. Patients were considered to have deteriorated if their functional status as measured by Barthel Index or Lawton IADL scores decreased in a significant way during the six months of follow up. Barthel Index and/or Lawton IADL scores fell at six months after the fracture in 33% of participants. This functional decline was more frequent in patients with comorbidity (p < 0.0001), polypharmacy (p < 0.0001), low health-related quality of life prior to the fall (p < 0.0001) and lower educational level (p = 0.009). The derived multivariate models show that patients that become dependent six months after the fall, have advanced age, severe chronic diseases, low functional performance prior to the fracture, and repeated episodes of accidental falls. This profile is consistent with a frailty phenotype. Wrist fractures are associated to the occurrence of dependence, especially in frail patients. These patients could benefit from being identified at the time the fracture is treated, in order to tackle their complex needs and so, prevent some of the burden of dependence generated by these fractures.

  12. Fractual interrelationships in field and seismic data. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-01-07

    Fractals provide a description of physical patterns over a range of scales in both time and space. Studies presented herein examine the fractal characteristics of various geological variables such as deformed bed-lengths, fold relief, seismic reflection arrival time variations, drainage and topographic patterns, and fracture systems. The studies are also extended to consider the possibility that the fractal characteristics of these variables are interrelated. Fractal interrelationships observed in these studies provide a method for relating variations in the fractal characteristics of seismic reflection events from reservoir intervals to the fractal characteristics of reservoir fracture systems, faults, and fold distributions. Themore » work is motivated by current exploration and development interests to detect fractured reservoirs and to accurately predict flow rates and flow patterns within the fractured reservoir. Accurate prediction requires an understanding of several reservoir properties including the fractal geometry of the reservoir fracture network. Results of these studies provide a method to remotely assess the fractal characteristics of a fractured reservoir, and help guide field development activities. The most significant outgrowth of this research is that the fractal properties of structural relief inferred from seismic data and structural cross sections provide a quantitative means to characterize and compare complex structural patterns. Production from fractured reservoirs is the result of complex structural and stratigraphic controls; hence, the import of fractal characterization to the assessment of fractured reservoirs lies in its potential to quantitatively define interrelationships between subtle structural variation and production. The potential uses are illustrated using seismic data from the Granny Creek oil field in the Appalachian Plateau.« less

  13. Fracture-permeability behavior of shale

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carey, J. William; Lei, Zhou; Rougier, Esteban

    The fracture-permeability behavior of Utica shale, an important play for shale gas and oil, was investigated using a triaxial coreflood device and X-ray tomography in combination with finite-discrete element modeling (FDEM). Fractures generated in both compression and in a direct-shear configuration allowed permeability to be measured across the faces of cylindrical core. Shale with bedding planes perpendicular to direct-shear loading developed complex fracture networks and peak permeability of 30 mD that fell to 5 mD under hydrostatic conditions. Shale with bedding planes parallel to shear loading developed simple fractures with peak permeability as high as 900 mD. In addition tomore » the large anisotropy in fracture permeability, the amount of deformation required to initiate fractures was greater for perpendicular layering (about 1% versus 0.4%), and in both cases activation of existing fractures are more likely sources of permeability in shale gas plays or damaged caprock in CO₂ sequestration because of the significant deformation required to form new fracture networks. FDEM numerical simulations were able to replicate the main features of the fracturing processes while showing the importance of fluid penetration into fractures as well as layering in determining fracture patterns.« less

  14. Fracture-permeability behavior of shale

    DOE PAGES

    Carey, J. William; Lei, Zhou; Rougier, Esteban; ...

    2015-05-08

    The fracture-permeability behavior of Utica shale, an important play for shale gas and oil, was investigated using a triaxial coreflood device and X-ray tomography in combination with finite-discrete element modeling (FDEM). Fractures generated in both compression and in a direct-shear configuration allowed permeability to be measured across the faces of cylindrical core. Shale with bedding planes perpendicular to direct-shear loading developed complex fracture networks and peak permeability of 30 mD that fell to 5 mD under hydrostatic conditions. Shale with bedding planes parallel to shear loading developed simple fractures with peak permeability as high as 900 mD. In addition tomore » the large anisotropy in fracture permeability, the amount of deformation required to initiate fractures was greater for perpendicular layering (about 1% versus 0.4%), and in both cases activation of existing fractures are more likely sources of permeability in shale gas plays or damaged caprock in CO₂ sequestration because of the significant deformation required to form new fracture networks. FDEM numerical simulations were able to replicate the main features of the fracturing processes while showing the importance of fluid penetration into fractures as well as layering in determining fracture patterns.« less

  15. Streaming potential modeling in fractured rock: Insights into the identification of hydraulically active fractures

    NASA Astrophysics Data System (ADS)

    Roubinet, D.; Linde, N.; Jougnot, D.; Irving, J.

    2016-05-01

    Numerous field experiments suggest that the self-potential (SP) geophysical method may allow for the detection of hydraulically active fractures and provide information about fracture properties. However, a lack of suitable numerical tools for modeling streaming potentials in fractured media prevents quantitative interpretation and limits our understanding of how the SP method can be used in this regard. To address this issue, we present a highly efficient two-dimensional discrete-dual-porosity approach for solving the fluid flow and associated self-potential problems in fractured rock. Our approach is specifically designed for complex fracture networks that cannot be investigated using standard numerical methods. We then simulate SP signals associated with pumping conditions for a number of examples to show that (i) accounting for matrix fluid flow is essential for accurate SP modeling and (ii) the sensitivity of SP to hydraulically active fractures is intimately linked with fracture-matrix fluid interactions. This implies that fractures associated with strong SP amplitudes are likely to be hydraulically conductive, attracting fluid flow from the surrounding matrix.

  16. Safe surgical technique for associated acetabular fractures

    PubMed Central

    2013-01-01

    Associated acetabular fractures are challenging injuries to manage. The complex surgical approaches and the technical difficulty in achieving anatomical reduction imply that the learning curve to achieve high-quality care of patients with such challenging injuries is extremely steep. This first article in the Journal’s “Safe Surgical Technique” section presents the standard surgical care, in conjunction with intraoperative tips and tricks, for the safe management of all subgroups of associated acetabular fractures. PMID:23414782

  17. Poroelastic references

    DOE Data Explorer

    Morency, Christina

    2014-12-12

    This file contains a list of relevant references on the Biot theory (forward and inverse approaches), the double-porosity and dual-permeability theory, and seismic wave propagation in fracture porous media, in RIS format, to approach seismic monitoring in a complex fractured porous medium such as Brady?s Geothermal Field.

  18. Should money follow the patient: Financial implication for being the National Centre for the Treatment and Management of Pelvic and Acetabular Fractures in Ireland.

    PubMed

    Kelly, M E; Leonard, M; Green, C; Beggs, R; Cheung, C; McElwain, J; Morris, S

    2013-12-01

    Pelvic and acetabular fractures are complex injuries requiring specialist treatment. Our institution is the National Centre for Treatment and Management of these injuries. To audit all referrals to our institution over a 6-month period and calculate the cost incurred by being the national referral centre. Retrospective review of database, and subsequent allocation of Casemix points to assess total cost of treatment for each patient referred to our institution. 103 patients referred with pelvic or acetabular fracture for operative management. The furthest referral distance was 181miles. Over-all, the length of stay was 15.4 days. The average inclusive cost for a referral to our unit for operative management was €16,302. Pelvic and acetabular fractures are complex injuries that require specialist referral unit management. However for these units to remain sustainable money needs to "follow the patient". Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  19. Fracture line morphology of complex proximal humeral fractures.

    PubMed

    Hasan, Afsana P; Phadnis, Joideep; Jaarsma, Ruurd L; Bain, Gregory I

    2017-10-01

    The aim of this study was to assess proximal humeral fracture patterns using 3-dimensional computed tomography images and relate them to the normal osseous landmarks and soft-tissue attachments. Forty-eight 3-dimensional computed tomography scans of proximal humeral fractures were retrospectively collected, and the fractures were transcribed onto proximal humeral templates. We analyzed the common location and orientation of the fracture lines, with a focus on fractures of the articular surface, tuberosities, metaphysis, and proximal diaphysis. These fractures were compared with the attachments of the rotator cuff and glenohumeral capsule. Fifty-two percent of the fractures involved the articular surface. No fractures passed through the bicipital groove, and fractures were more commonly found on the posterior lesser tuberosity and on the anterior greater tuberosity, coinciding with the intervals between the rotator cuff tendon insertions. Intracapsular fractures of the calcar were more common (68%) than extracapsular fractures (32%). On the anterolateral aspect of the proximal humerus, fractures radiated from the articular margin, vertically down through the tuberosity zone between the rotator cuff footprints, meeting horizontally oriented fractures in the metaphyseal zone. On the posterior aspect, vertical fractures from the tuberosity zone continued downward to the metaphyseal zone adjacent to the infraspinatus and teres minor footprints. Fractures of the proximal humerus follow characteristic patterns. Fractures frequently split the greater tuberosity and are closely related to the intervals of the rotator cuff attachments. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  20. Implications of heterogeneous fracture distribution on reservoir quality; an analogue from the Torridon Group sandstone, Moine Thrust Belt, NW Scotland

    NASA Astrophysics Data System (ADS)

    Watkins, Hannah; Healy, David; Bond, Clare E.; Butler, Robert W. H.

    2018-03-01

    Understanding fracture network variation is fundamental in characterising fractured reservoirs. Simple relationships between fractures, stress and strain are commonly assumed in fold-thrust structures, inferring relatively homogeneous fracture patterns. In reality fractures are more complex, commonly appearing as heterogeneous networks at outcrop. We use the Achnashellach Culmination (NW Scotland) as an outcrop analogue to a folded tight sandstone reservoir in a thrust belt. We present fracture data is collected from four fold-thrust structures to determine how fracture connectivity, orientation, permeability anisotropy and fill vary at different structural positions. We use a 3D model of the field area, constructed using field observations and bedding data, and geomechanically restored using Move software, to determine how factors such as fold curvature and strain influence fracture variation. Fracture patterns in the Torridon Group are consistent and predictable in high strain forelimbs, however in low strain backlimbs fracture patterns are inconsistent. Heterogeneities in fracture connectivity and orientation in low strain regions do not correspond to fluctuations in strain or fold curvature. We infer that where strain is low, other factors such as lithology have a greater control on fracture formation. Despite unpredictable fracture attributes in low strain regions, fractured reservoir quality would be highest here because fractures in high strain forelimbs are infilled with quartz. Heterogeneities in fracture attribute data on fold backlimbs mean that fractured reservoir quality and reservoir potential is difficult to predict.

  1. Fast Physically Accurate Rendering of Multimodal Signatures of Distributed Fracture in Heterogeneous Materials.

    PubMed

    Visell, Yon

    2015-04-01

    This paper proposes a fast, physically accurate method for synthesizing multimodal, acoustic and haptic, signatures of distributed fracture in quasi-brittle heterogeneous materials, such as wood, granular media, or other fiber composites. Fracture processes in these materials are challenging to simulate with existing methods, due to the prevalence of large numbers of disordered, quasi-random spatial degrees of freedom, representing the complex physical state of a sample over the geometric volume of interest. Here, I develop an algorithm for simulating such processes, building on a class of statistical lattice models of fracture that have been widely investigated in the physics literature. This algorithm is enabled through a recently published mathematical construction based on the inverse transform method of random number sampling. It yields a purely time domain stochastic jump process representing stress fluctuations in the medium. The latter can be readily extended by a mean field approximation that captures the averaged constitutive (stress-strain) behavior of the material. Numerical simulations and interactive examples demonstrate the ability of these algorithms to generate physically plausible acoustic and haptic signatures of fracture in complex, natural materials interactively at audio sampling rates.

  2. In situ measurements of hydraulic fracture behavior, PTE-3. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warpinski, N.R.

    Measurements of width and pressure in a propagating hydraulic fracture have been made in tests conducted at DOE`s Nevada Test Site. This was accomplished by creating an "instrumented fracture" at a tunnel complex (at a depth of 1400 ft) where realistic in situ conditions prevail, particularly with respect to stress and geologic features such as natural fractures and material anisotropy. Analyses of these data show that the pressure drop along the fracture length is much larger than predicted by viscous theory currently in use in models today. This is apparently due to the tortuosity of the fracture path, multiple fracturemore » strands, roughness, and sharp turns (corners) in the flow path due to natural fractures and rock property variations. It suggests that fracture design models need to be updated to include a more realistic friction factor so that fracture lengths are not overestimated. The width and pressure profiles near the crack tip have been investigated in some detail, including the length of the unwetted region and the tapering of the crack tip. The overall fracture behavior has been compared with published fracture models. Mineback of the fracture provided evidence of the geometry of the fracture and details of surface features. 35 refs., 89 figs., 30 tabs.« less

  3. Modeling Single Well Injection-Withdrawal (SWIW) Tests for Characterization of Complex Fracture-Matrix Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cotte, F.P.; Doughty, C.; Birkholzer, J.

    2010-11-01

    The ability to reliably predict flow and transport in fractured porous rock is an essential condition for performance evaluation of geologic (underground) nuclear waste repositories. In this report, a suite of programs (TRIPOLY code) for calculating and analyzing flow and transport in two-dimensional fracture-matrix systems is used to model single-well injection-withdrawal (SWIW) tracer tests. The SWIW test, a tracer test using one well, is proposed as a useful means of collecting data for site characterization, as well as estimating parameters relevant to tracer diffusion and sorption. After some specific code adaptations, we numerically generated a complex fracture-matrix system for computationmore » of steady-state flow and tracer advection and dispersion in the fracture network, along with solute exchange processes between the fractures and the porous matrix. We then conducted simulations for a hypothetical but workable SWIW test design and completed parameter sensitivity studies on three physical parameters of the rock matrix - namely porosity, diffusion coefficient, and retardation coefficient - in order to investigate their impact on the fracture-matrix solute exchange process. Hydraulic fracturing, or hydrofracking, is also modeled in this study, in two different ways: (1) by increasing the hydraulic aperture for flow in existing fractures and (2) by adding a new set of fractures to the field. The results of all these different tests are analyzed by studying the population of matrix blocks, the tracer spatial distribution, and the breakthrough curves (BTCs) obtained, while performing mass-balance checks and being careful to avoid some numerical mistakes that could occur. This study clearly demonstrates the importance of matrix effects in the solute transport process, with the sensitivity studies illustrating the increased importance of the matrix in providing a retardation mechanism for radionuclides as matrix porosity, diffusion coefficient, or retardation coefficient increase. Interestingly, model results before and after hydrofracking are insensitive to adding more fractures, while slightly more sensitive to aperture increase, making SWIW tests a possible means of discriminating between these two potential hydrofracking effects. Finally, we investigate the possibility of inferring relevant information regarding the fracture-matrix system physical parameters from the BTCs obtained during SWIW testing.« less

  4. Serial Versus Direct Dilation of Small Diameter Stents Results in a More Predictable and Complete Intentional Transcatheter Stent Fracture: A PICES Bench Testing Study.

    PubMed

    Crystal, Matthew A; Morgan, Gareth J; Danon, Saar; Gray, Robert G; Gruenstein, Daniel H; Gordon, Brent M; Goldstein, Bryan H

    2018-01-01

    Balloon-expandable stents, implanted in infants and children with congenital heart disease (CHD), often require redilation to match somatic growth. Small diameter stents may eventually require longitudinal surgical transection to prevent iatrogenic vascular stenosis. Intentional transcatheter stent fracture (TSF) is an emerging alternative approach to stent transection, but little is known about the optimal stent substrate and best protocol to improve the likelihood of successful TSF. Bench testing was performed with a stent dilation protocol. After recording baseline characteristics, stents were serially or directly dilated using ultra-high-pressure balloons (UHPB) until fracture occurred or further stent dilation was not possible. Stent characteristics recorded were as follows: cell design, metallurgy, mechanism, and uniformity of fracture. Stents tested included bare-metal coronary stents, premounted small diameter stents, and ePTFE-covered small diameter premounted stents. Ninety-four stents representing 9 distinct models were maximally dilated, with 80 (85%) demonstrating evidence of fracture. Comprehensive fracture details were recorded in 64 stents: linear and complete in 34/64 stents (53.1%), linear and incomplete in 9/64 stents (14.1%), transverse/complex and complete in 6/64 stents (9.4%), and transverse/complex and incomplete in 15/64 stents (23.4%). Stent fracture was not accomplished in some stent models secondary to significant shortening, i.e., "napkin-ring" formation. Serial dilation resulted in evidence of fracture in 62/67 (92.5%) stents compared with 18/27 (66.7%) stents in the direct dilation group (p = 0.003). Intentional TSF is feasible in an ex vivo model. Serial dilation more reliably expanded the stent and allowed for ultimate stent fracture, whereas direct large diameter dilation of stents was more likely to generate a "napkin-ring" configuration, which may be more resistant to fracture. In vivo animal and human testing is necessary to better understand the response to attempted TSF for newly developed stents as well as those currently in use.

  5. A Computational/Experimental Platform for Investigating Three-Dimensional Puzzle Solving of Comminuted Articular Fractures

    PubMed Central

    Thomas, Thaddeus P.; Anderson, Donald D.; Willis, Andrew R.; Liu, Pengcheng; Frank, Matthew C.; Marsh, J. Lawrence; Brown, Thomas D.

    2011-01-01

    Reconstructing highly comminuted articular fractures poses a difficult surgical challenge, akin to solving a complicated three-dimensional (3D) puzzle. Pre-operative planning using CT is critically important, given the desirability of less invasive surgical approaches. The goal of this work is to advance 3D puzzle solving methods toward use as a pre-operative tool for reconstructing these complex fractures. Methodology for generating typical fragmentation/dispersal patterns was developed. Five identical replicas of human distal tibia anatomy, were machined from blocks of high-density polyetherurethane foam (bone fragmentation surrogate), and were fractured using an instrumented drop tower. Pre- and post-fracture geometries were obtained using laser scans and CT. A semi-automatic virtual reconstruction computer program aligned fragment native (non-fracture) surfaces to a pre-fracture template. The tibias were precisely reconstructed with alignment accuracies ranging from 0.03-0.4mm. This novel technology has potential to significantly enhance surgical techniques for reconstructing comminuted intra-articular fractures, as illustrated for a representative clinical case. PMID:20924863

  6. Adjustable patella grapple versus cannulated screw and cable technique for treatment of transverse patellar fractures.

    PubMed

    Yan, Ning; Yang, Anli; Liu, Xiaodong; Cai, Feng; Liu, Liang; Chang, Shimin

    2014-03-01

    Although the cannulated screw and cable (CSC) tension band technique is an effective method for fixation of transverse patellar fractures, it has shortcomings, such as extensive soft tissue damage, osseous substance damage, and complex manipulation. We conducted a retrospective comparison of the adjustable patella grapple (APG) technique and the CSC tension band technique. We retrospectively reviewed 78 patients with transverse patellar fractures (45 in the APG group and 33 in the CSC group). Follow-up was 18 months. Comparison criteria were operation time, fracture reduction, fracture healing time, the knee injury and osteoarthritis outcome score for knee function, and complications. The APG group showed shorter operation time and equal fracture reduction, fracture healing time, and knee function compared with the CSC group. Eleven patients in the APG group experienced skin irritation generated by implants. There was no complication in the CSC group. The APG technique should be considered as an alternative method for treatment of transverse patellar fractures.

  7. Development of a new semi-analytical model for cross-borehole flow experiments in fractured media

    USGS Publications Warehouse

    Roubinet, Delphine; Irving, James; Day-Lewis, Frederick D.

    2015-01-01

    Analysis of borehole flow logs is a valuable technique for identifying the presence of fractures in the subsurface and estimating properties such as fracture connectivity, transmissivity and storativity. However, such estimation requires the development of analytical and/or numerical modeling tools that are well adapted to the complexity of the problem. In this paper, we present a new semi-analytical formulation for cross-borehole flow in fractured media that links transient vertical-flow velocities measured in one or a series of observation wells during hydraulic forcing to the transmissivity and storativity of the fractures intersected by these wells. In comparison with existing models, our approach presents major improvements in terms of computational expense and potential adaptation to a variety of fracture and experimental configurations. After derivation of the formulation, we demonstrate its application in the context of sensitivity analysis for a relatively simple two-fracture synthetic problem, as well as for field-data analysis to investigate fracture connectivity and estimate fracture hydraulic properties. These applications provide important insights regarding (i) the strong sensitivity of fracture property estimates to the overall connectivity of the system; and (ii) the non-uniqueness of the corresponding inverse problem for realistic fracture configurations.

  8. Fluid-driven fracture propagation in heterogeneous media: Probability distributions of fracture trajectories

    NASA Astrophysics Data System (ADS)

    Santillán, David; Mosquera, Juan-Carlos; Cueto-Felgueroso, Luis

    2017-11-01

    Hydraulic fracture trajectories in rocks and other materials are highly affected by spatial heterogeneity in their mechanical properties. Understanding the complexity and structure of fluid-driven fractures and their deviation from the predictions of homogenized theories is a practical problem in engineering and geoscience. We conduct a Monte Carlo simulation study to characterize the influence of heterogeneous mechanical properties on the trajectories of hydraulic fractures propagating in elastic media. We generate a large number of random fields of mechanical properties and simulate pressure-driven fracture propagation using a phase-field model. We model the mechanical response of the material as that of an elastic isotropic material with heterogeneous Young modulus and Griffith energy release rate, assuming that fractures propagate in the toughness-dominated regime. Our study shows that the variance and the spatial covariance of the mechanical properties are controlling factors in the tortuousness of the fracture paths. We characterize the deviation of fracture paths from the homogenous case statistically, and conclude that the maximum deviation grows linearly with the distance from the injection point. Additionally, fracture path deviations seem to be normally distributed, suggesting that fracture propagation in the toughness-dominated regime may be described as a random walk.

  9. Fluid-driven fracture propagation in heterogeneous media: Probability distributions of fracture trajectories.

    PubMed

    Santillán, David; Mosquera, Juan-Carlos; Cueto-Felgueroso, Luis

    2017-11-01

    Hydraulic fracture trajectories in rocks and other materials are highly affected by spatial heterogeneity in their mechanical properties. Understanding the complexity and structure of fluid-driven fractures and their deviation from the predictions of homogenized theories is a practical problem in engineering and geoscience. We conduct a Monte Carlo simulation study to characterize the influence of heterogeneous mechanical properties on the trajectories of hydraulic fractures propagating in elastic media. We generate a large number of random fields of mechanical properties and simulate pressure-driven fracture propagation using a phase-field model. We model the mechanical response of the material as that of an elastic isotropic material with heterogeneous Young modulus and Griffith energy release rate, assuming that fractures propagate in the toughness-dominated regime. Our study shows that the variance and the spatial covariance of the mechanical properties are controlling factors in the tortuousness of the fracture paths. We characterize the deviation of fracture paths from the homogenous case statistically, and conclude that the maximum deviation grows linearly with the distance from the injection point. Additionally, fracture path deviations seem to be normally distributed, suggesting that fracture propagation in the toughness-dominated regime may be described as a random walk.

  10. Laboratory Mid-frequency (Kilohertz) Range Seismic Property Measurements and X-ray CT Imaging of Fractured Sandstone Cores During Supercritical CO2 Injection

    NASA Astrophysics Data System (ADS)

    Nakagawa, S.; Kneafsey, T. J.; Chang, C.; Harper, E.

    2014-12-01

    During geological sequestration of CO2, fractures are expected to play a critical role in controlling the migration of the injected fluid in reservoir rock. To detect the invasion of supercritical (sc-) CO2 and to determine its saturation, velocity and attenuation of seismic waves can be monitored. When both fractures and matrix porosity connected to the fractures are present, wave-induced dynamic poroelastic interactions between these two different types of rock porosity—high-permeability, high-compliance fractures and low-permeability, low-compliance matrix porosity—result in complex velocity and attenuation changes of compressional waves as scCO2 invades the rock. We conducted core-scale laboratory scCO2 injection experiments on small (diameter 1.5 inches, length 3.5-4 inches), medium-porosity/permeability (porosity 15%, matrix permeability 35 md) sandstone cores. During the injection, the compressional and shear (torsion) wave velocities and attenuations of the entire core were determined using our Split Hopkinson Resonant Bar (short-core resonant bar) technique in the frequency range of 1-2 kHz, and the distribution and saturation of the scCO2 determined via X-ray CT imaging using a medical CT scanner. A series of tests were conducted on (1) intact rock cores, (2) a core containing a mated, core-parallel fracture, (3) a core containing a sheared core-parallel fracture, and (4) a core containing a sheared, core-normal fracture. For intact cores and a core containing a mated sheared fracture, injections of scCO2 into an initially water-saturated sample resulted in large and continuous decreases in the compressional velocity as well as temporary increases in the attenuation. For a sheared core-parallel fracture, large attenuation was also observed, but almost no changes in the velocity occurred. In contrast, a sample containing a core-normal fracture exhibited complex behavior of compressional wave attenuation: the attenuation peaked as the leading edge of the scCO2 approached the fracture; followed by an immediate drop as scCO2 invaded the fracture; and by another, gradual increase as the scCO2 infiltrated into the other side of the fracture. The compressional wave velocity declined monotonically, but the rate of velocity decrease changed with the changes in attenuation.

  11. FACTORS ASSOCIATED WITH COMPLEX REGIONAL PAIN SYNDROME IN SURGICALLY TREATED DISTAL RADIUS FRACTURE

    PubMed Central

    ORTIZ-ROMERO, JOEL; BERMUDEZ-SOTO, IGNACIO; TORRES-GONZÁLEZ, RUBÉN; ESPINOZA-CHOQUE, FERNANDO; ZAZUETA-HERNANDEZ, JESÚS ABRAHAM; PEREZ-ATANASIO, JOSÉ MANUEL

    2017-01-01

    ABSTRACT Objective: The aim of this study was to identify factors associated with developing complex regional pain syndrome (CRPS) after surgical treatment for distal radius fracture (DRF). Methods: This case-control study analyzed patients seen from January 2014 to January 2016. Results: In our sample of 249 patients, 4% developed CRPS. Associated factors were economic compensation via work disability (odds ratio [OR] 14.3), age (OR 9.38), associated fracture (OR 12.94), and level of impact (OR 6.46), as well as psychiatric history (OR 7.21). Conclusions: Economically-productive aged patients with a history of high-impact trauma and patients with a history of psychiatric disorders have greater risk of developing CRPS after DRF. Level of Evidence III, Case-Control Study. PMID:29081703

  12. The influence of open fracture anisotropy on CO2 movement within geological storage complexes

    NASA Astrophysics Data System (ADS)

    Bond, C. E.; Wightman, R.; Ringrose, P. S.

    2012-12-01

    Carbon mitigation through the geological storage of carbon dioxide is dependent on the ability of geological formations to store CO2 trapping it within a geological storage complex. Secure long-term containment needs to be demonstrated, due to both political and social drivers, meaning that this containment must be verifiable over periods of 100-105 years. The effectiveness of sub-surface geological storage systems is dependent on trapping CO2 within a volume of rock and is reliant on the integrity of the surrounding rocks, including their chemical and physical properties, to inhibit migration to the surface. Oil and gas reservoir production data, and field evidence show that fracture networks have the potential to act as focused pathways for fluid movement. Fracture networks can allow large volumes of fluid to migrate to the surface within the time scales of interest. In this paper we demonstrate the importance of predicting the effects of fracture networks in storage, using a case study from the In Salah CO2 storage site, and show how the fracture permeability is closely controlled by the stress regime that determines the open fracture network. Our workflow combines well data of imaged fractures, with a discrete fracture network (DFN) model of tectonically induced fractures, within the horizon of interest. The modelled and observed fractures have been compared and combined with present day stress data to predict the open fracture network and its implications for anisotropic movement of CO2 in the sub-surface. The created fracture network model has been used to calculate the 2D permeability tensor for the reservoir for two scenarios: 1) a model in which all fractures are permeable, based on the whole DFN model and 2) those fractures determined to be in dilatational failure under the present day stress regime, a sub-set of the DFN. The resulting permeability anisotropy tensors show distinct anisotropies for the predicted CO2 movement within the reservoir. These predictions have been compared with InSAR imagery of surface uplift, used as an indicator of fluid pressure and movement in the sub-surface, around the CO2 injection wells. The analysis shows that the permeability tensor with the greatest anisotropy, that for the DFN sub-set of open fractures, matches well with the anisotropy in surface uplift imaged by InSAR. We demonstrate that predicting fracture networks alone does not predict fluid movement in the sub-surface, and that fracture permeability is closely controlled by the stress regime that determines the open fracture network. Our results show that a workflow of fracture network prediction combined with present day stress analysis can be used to successfully predict CO2 movement in the sub-surface at an active injection site.

  13. Simulation of Grouting Process in Rock Masses Under a Dam Foundation Characterized by a 3D Fracture Network

    NASA Astrophysics Data System (ADS)

    Deng, Shaohui; Wang, Xiaoling; Yu, Jia; Zhang, Yichi; Liu, Zhen; Zhu, Yushan

    2018-06-01

    Grouting plays a crucial role in dam safety. Due to the concealment of grouting activities, complexity of fracture distribution in rock masses and rheological properties of cement grout, it is difficult to analyze the effects of grouting. In this paper, a computational fluid dynamics (CFD) simulation approach of dam foundation grouting based on a 3D fracture network model is proposed. In this approach, the 3D fracture network model, which is based on an improved bootstrap sampling method and established by VisualGeo software, can provide a reliable and accurate geometric model for CFD simulation of dam foundation grouting. Based on the model, a CFD simulation is performed, in which the Papanastasiou regularized model is used to express the grout rheological properties, and the volume of fluid technique is utilized to capture the grout fronts. Two sets of tests are performed to verify the effectiveness of the Papanastasiou regularized model. When applying the CFD simulation approach for dam foundation grouting, three technical issues can be solved: (1) collapsing potential of the fracture samples, (2) inconsistencies in the geometric model in actual fractures under complex geological conditions, and (3) inappropriate method of characterizing the rheological properties of cement grout. The applicability of the proposed approach is demonstrated by an illustrative case study—a hydropower station dam foundation in southwestern China.

  14. Subcritical crack growth and other time- and environment-dependent behavior in crustal rocks

    NASA Technical Reports Server (NTRS)

    Swanson, P. L.

    1984-01-01

    Stable crack growth strongly influences both the fracture strength of brittle rocks and some of the phenomena precursory to catastrophic failure. Quantification of the time and environment dependence of fracture propagation is attempted with the use of a fracture mechanics technique. Some of the difficulties encountered when applying techniques originally developed for simple synthetic materials to complex materials like rocks are examined. A picture of subcritical fracture propagation is developed that embraces the essential ingredients of the microstructure, a microcrack process zone, and the different roles that the environment plays. To do this, the results of (1) fracture mechanics experiments on five rock types, (2) optical and scanning electron microscopy, (3) studies of microstructural aspects of fracture in ceramics, and (4) exploratory tests examining the time-dependent response of rock to the application of water are examined.

  15. External fixation techniques for distal radius fractures.

    PubMed

    Capo, John T; Swan, Kenneth G; Tan, Virak

    2006-04-01

    Fractures of the distal radius are common injuries. Low-energy or high-energy mechanisms may be involved. Unstable distal radius fractures present a challenge to the treating orthopaedic surgeon. External fixation is a valuable instrument for fracture reduction and stabilization. Limited open incisions, early range of motion, and treatment of complex wounds are a few of the benefits of external fixation. Fixators may be spanning or nonbridging and may be used alone or in combination with other stabilization methods to obtain and maintain distal radius fracture reduction. Augmentation with percutaneous wires allows for optimal fracture stabilization with physiologic alignment of the wrist. Moderate distraction at the carpus does not induce postoperative stiffness. The distal radioulnar joint must be assessed and may need to be stabilized. Complications of external fixation are usually minor, but must be anticipated and treated early. Level V (expert opinion).

  16. Healing of the bone with anti-fracture drugs.

    PubMed

    Vannucci, Letizia; Brandi, Maria Luisa

    2016-12-01

    Fracture healing is a complex physiological process. As impaired fracture healing is more frequent in osteoporotic subjects, anti-osteoporotic drugs could have some impact on this process. Areas covered: We reviewed the current literature to evaluate the effects of these drugs on fracture healing and their potential role in supporting this process, especially when impaired. A PubMed/Medline search was undertaken combining the terms 'fracture healing', 'anti-resorptive drugs', 'anabolic agents', 'anti-osteoporotic drugs'. Expert opinion: As clinical evidence on the role of anti-osteoporotic drugs in the process of fracture healing consists mainly of case reports or studies with a relatively small number of patients, large randomized clinical trials are needed in order to extend to the human setting the promising results on these agents as inductors or co-adjuvants of bone healing derived from animal studies.

  17. Floating elbow injuries in adults: prognostic factors affecting clinical outcomes.

    PubMed

    Ditsios, Konstantinos; Boutsiadis, Achilleas; Papadopoulos, Pericles; Karataglis, Dimitrios; Givissis, Panagiotis; Hatzokos, Ippokratis; Christodoulou, Anastasios

    2013-01-01

    Floating elbow fractures in adults are rare and complex injuries with unpredictable outcomes. The present study was designed to assess our experience, analyze possible compilations and illustrate prognostic factors of the final outcome. Between 2002 and 2009, 19 patients with floating elbow fractures were treated in our department (mean follow-up, 26 months). The fractures were open in 10 patients (52.6%), and concomitant nerve palsy was present in 10 patients. Although the term "floating elbow" refers only to concomitant ipsilateral humeral and forearm shaft fractures, we also included injuries with intra-articular involvement. We categorized the patients into 4 groups: group I (10 patients) included shaft fractures of humerus and forearm, group IIa (5 patients) and IIb (1 patient) included partial intra-articular injuries, and group III (3 patients) involved only intra-articular comminuted fractures of the elbow region. Fracture healing was observed 14 weeks postoperatively, except in 2 patients, in which elbow arthroplasty was applied, and in 1 with brachial artery injury. Nine patients with nerve neuropraxia recovered 4 months postoperatively, and tendon transfers were necessary in 1 patient. Recovery in patients with nerve palsy was worse than in those without nerve injury (Mayo Elbow Performance Score, 73 vs 88.34; Khalfayan score, 72 vs 88.3). In addition, intra-articular involvement (groups II and III) negatively influenced the final clinical outcome compared with isolated shaft fractures (group I; Mayo Elbow Performance Score, 71.1 vs 88.5; Khalfayan score, 72.67 vs 86.1). Although the nature of floating elbow injuries is complex, the presence of nerve injury and intra-articular involvement predispose to worse clinical outcomes. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  18. A new "virtual" patient pathway for the management of radial head and neck fractures.

    PubMed

    Jayaram, Prem R; Bhattacharyya, Rahul; Jenkins, Paul J; Anthony, Iain; Rymaszewski, Lech A

    2014-03-01

    Minimally displaced radial head and neck fractures are common and the outcome with conservative treatment is generally excellent. A new protocol was introduced to manage patients with these suspected fractures at a major urban hospital. Simple, undisplaced fractures without other associated injuries or instability were discharged with structured advice but no further face-to-face review. Patients with more complex injuries were reviewed at a "virtual clinic." The aim of this study was to examine the outcome of this process in terms of patient flow, satisfaction, reattendance, and reintervention. The 202 eligible patients, who presented during a 1-year period from October 2011 to October 2012, were identified retrospectively from a prospectively collected administrative database. Mason type III and IV fractures were excluded. A questionnaire was administered by mail or phone call to assess satisfaction with the process, information received, and function. Twenty (10%) patients required face-to-face review in a clinic, whereas 182 (90%) were managed with direct discharge; 155 patients responded to the survey (77%). The overall satisfaction rate was 96% in the suspected fracture group and 87% in the definite fracture group (P = .08). Satisfaction with the information provided was 95%. Two (1%) required late surgical intervention. In this study, patients with suspected Mason I or II fractures were managed with limited face-to-face follow-up with high satisfaction rates. The reintervention rate was extremely low. This process has significant benefits to patients, who have fewer hospital visits, and to orthopaedic departments, which have more time to devote to complex cases. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  19. Gradual Reduction of Chronic Fracture Dislocation of the Ankle Using Ilizarov/Taylor Spatial Frame

    PubMed Central

    Deland, Jonathan T.; Rozbruch, S. Robert

    2010-01-01

    With the advances in trauma care, chronic fracture dislocation of the ankle is not a condition commonly seen in modern clinical practice. When encountered, it can be difficult to preserve the ankle joint. We present a case of a 65-year-old female, with a chronic fracture dislocation of the ankle. The ankle joint was subluxated with posterior translation of the talus, displacement of the posterior malleolus fragment, and a distal fibula fracture. A minimally traumatic approach was devised to treat this complex fracture dislocation which included gradual reduction of the ankle with a Taylor spatial frame, followed by stabilization with internal fixation and removal of the frame. Bony union and restoration of the ankle joint congruency was achieved. PMID:22294963

  20. Scale-Dependent Fracture-Matrix Interactions And Their Impact on Radionuclide Transport - Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Detwiler, Russell

    Matrix diffusion and adsorption within a rock matrix are widely regarded as important mechanisms for retarding the transport of radionuclides and other solutes in fractured rock (e.g., Neretnieks, 1980; Tang et al., 1981; Maloszewski and Zuber, 1985; Novakowski and Lapcevic, 1994; Jardine et al., 1999; Zhou and Xie, 2003; Reimus et al., 2003a,b). When remediation options are being evaluated for old sources of contamination, where a large fraction of contaminants reside within the rock matrix, slow diffusion out of the matrix greatly increases the difficulty and timeframe of remediation. Estimating the rates of solute exchange between fractures and the adjacentmore » rock matrix is a critical factor in quantifying immobilization and/or remobilization of DOE-relevant contaminants within the subsurface. In principle, the most rigorous approach to modeling solute transport with fracture-matrix interaction would be based on local-scale coupled advection-diffusion/dispersion equations for the rock matrix and in discrete fractures that comprise the fracture network (Discrete Fracture Network and Matrix approach, hereinafter referred to as DFNM approach), fully resolving aperture variability in fractures and matrix property heterogeneity. However, such approaches are computationally demanding, and thus, many predictive models rely upon simplified models. These models typically idealize fracture rock masses as a single fracture or system of parallel fractures interacting with slabs of porous matrix or as a mobile-immobile or multi-rate mass transfer system. These idealizations provide tractable approaches for interpreting tracer tests and predicting contaminant mobility, but rely upon a fitted effective matrix diffusivity or mass-transfer coefficients. However, because these fitted parameters are based upon simplified conceptual models, their effectiveness at predicting long-term transport processes remains uncertain. Evidence of scale dependence of effective matrix diffusion coefficients obtained from tracer tests highlights this point and suggests that the underlying mechanisms and relationship between rock and fracture properties are not fully understood in large complex fracture networks. In this project, we developed a high-resolution DFN model of solute transport in fracture networks to explore and quantify the mechanisms that control transport in complex fracture networks and how these may give rise to observed scale-dependent matrix diffusion coefficients. Results demonstrate that small scale heterogeneity in the flow field caused by local aperture variability within individual fractures can lead to long-tailed breakthrough curves indicative of matrix diffusion, even in the absence of interactions with the fracture matrix. Furthermore, the temporal and spatial scale dependence of these processes highlights the inability of short-term tracer tests to estimate transport parameters that will control long-term fate and transport of contaminants in fractured aquifers.« less

  1. Risk assessment tools to identify women with increased risk of osteoporotic fracture: complexity or simplicity? A systematic review.

    PubMed

    Rubin, Katrine Hass; Friis-Holmberg, Teresa; Hermann, Anne Pernille; Abrahamsen, Bo; Brixen, Kim

    2013-08-01

    A huge number of risk assessment tools have been developed. Far from all have been validated in external studies, more of them have absence of methodological and transparent evidence, and few are integrated in national guidelines. Therefore, we performed a systematic review to provide an overview of existing valid and reliable risk assessment tools for prediction of osteoporotic fractures. Additionally, we aimed to determine if the performance of each tool was sufficient for practical use, and last, to examine whether the complexity of the tools influenced their discriminative power. We searched PubMed, Embase, and Cochrane databases for papers and evaluated these with respect to methodological quality using the Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS) checklist. A total of 48 tools were identified; 20 had been externally validated, however, only six tools had been tested more than once in a population-based setting with acceptable methodological quality. None of the tools performed consistently better than the others and simple tools (i.e., the Osteoporosis Self-assessment Tool [OST], Osteoporosis Risk Assessment Instrument [ORAI], and Garvan Fracture Risk Calculator [Garvan]) often did as well or better than more complex tools (i.e., Simple Calculated Risk Estimation Score [SCORE], WHO Fracture Risk Assessment Tool [FRAX], and Qfracture). No studies determined the effectiveness of tools in selecting patients for therapy and thus improving fracture outcomes. High-quality studies in randomized design with population-based cohorts with different case mixes are needed. Copyright © 2013 American Society for Bone and Mineral Research.

  2. Pelvic fracture in multiple trauma: are we still up-to-date with massive fluid resuscitation?

    PubMed

    Burkhardt, Markus; Kristen, Alexander; Culemann, Ulf; Koehler, Daniel; Histing, Tina; Holstein, Joerg H; Pizanis, Antonius; Pohlemann, Tim

    2014-10-01

    Until today the mortality of complex pelvic trauma remains unacceptably high. On the one hand this could be attributed to a biological limit of the survivable trauma load, on the other hand side an ongoing inadequate treatment might be conceivable too. For the management of multiple trauma patients with life-threatening pelvic fractures, there is ongoing international debate on the adequate therapeutic strategy, e.g. arterial embolization or pelvic packing, as well as aggressive or restrained volume therapy. Whereas traditional pelvis-specific trauma algorithms still recommend massive fluid resuscitation, there is upcoming evidence that a restrained volume therapy in the preclinical setting may improve trauma outcomes. Less intravenous fluid administration may also reduce haemodilution and concomitant trauma-associated coagulopathy. After linking the data of the TraumaRegister DGU(®) and the German Pelvic Injury Register, for the first time, the initial fluid management for complex pelvic traumas as well as for different Tile/OTA types of pelvic ring fractures could be addressed. Unfortunately, the results could not answer the question of the adequate fluid resuscitation but confirmed the actuality of massive fluid resuscitation in the prehospital and emergency room setting. Low-volume resuscitation seems not yet accepted in practice in managing multiple trauma patients with pelvic fractures at least in Germany. Nevertheless, prevention of exsanguination and of complications like multiple organ dysfunction syndrome still poses a major challenge in the management of complex pelvic ring injuries. Even nowadays, fluid management for trauma, not only for pelvic fractures, remains a controversial area and further research is mandatory. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Radiographic Outcomes of Dorsal Distraction Distal Radius Plating for Fractures With Dorsal Marginal Impaction.

    PubMed

    Huish, Eric G; Coury, John G; Ibrahim, Mohamed A; Trzeciak, Marc A

    2017-04-01

    The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results with prior publications for both external fixation and internal fixation with volar locked plates. Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (M.A.T. and M.A.I.) from May 30, 2013, to December 29, 2015, were identified and included in the study. Retrospective chart and radiograph review was performed on 19 patients, 11 male and 8 female, with mean age of 47.83 years (22-82). No patients were excluded from the study. All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49-129). Follow-up radiographs showed average radial inclination of 20.5° (13.2°-25.5°), radial height of 10.7 mm (7.5-14 mm), ulnar variance of -0.3 mm (-2.1 to 3.1 mm), and volar tilt of 7.9° (-3° to 15°). One patient had intra-articular step-off greater than 2 mm. Dorsal distraction plating of complex distal radius fractures yields good radiographic results with minimal complications. In cases of complex distal radius fractures including dorsal marginal impaction where volar plating is not considered adequate, a dorsal distraction plate should be considered as an alternative to external fixation due to reduced risk for infection and better control of volar tilt.

  4. Insight from simulations of single-well injection-withdrawal tracer tests on simple and complex fractures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsang, C.-F.; Doughty, C.

    2009-08-06

    The single-well injection withdrawal (SWIW) test, a tracer test utilizing only one well, is proposed as a useful contribution to site characterization of fractured rock, as well as providing parameters relevant to tracer diffusion and sorption. The usual conceptual model of flow and solute transport through fractured rock with low matrix permeability involves solute advection and dispersion through a fracture network coupled with diffusion and sorption into the surrounding rock matrix. Unlike two-well tracer tests, results of SWIW tests are ideally independent of advective heterogeneity, channeling and flow dimension, and, instead, focus on diffusive and sorptive characteristics of tracer (solute)more » transport. Thus, they can be used specifically to study such characteristics and evaluate the diffusive parameters associated with tracer transport through fractured media. We conduct simulations of SWIW tests on simple and complex fracture models, the latter being defined as having two subfractures with altered rock blocks in between and gouge material in their apertures. Using parameters from the Aspo site in Sweden, we calculate and study SWIW tracer breakthrough curves (BTCs) from a test involving four days of injection and then withdrawal. By examining the peak concentration C{sub pk} of the SWIW BTCs for a variety of parameters, we confirm that C{sub pk} is largely insensitive to the fracture advective flow properties, in particular to permeability heterogeneity over the fracture plane or to subdividing the flow into two subfractures in the third dimension orthogonal to the fracture plane. The peak arrival time t{sub pk} is not a function of fracture or rock properties, but is controlled by the time schedule of the SWIW test. The study shows that the SWIW test is useful for the study of tracer diffusion-sorption processes, including the effect of the so-called flow-wetted surface (FWS) of the fracture. Calculations with schematic models with different FWS values are conducted and the possibility of direct in situ measurement of FWS with SWIW tests is demonstrated.« less

  5. Garden City Vein Complex, Gale Crater, Mars: Implications for Late Diagenetic Fluid Flow

    NASA Astrophysics Data System (ADS)

    Kronyak, R. E.; Kah, L. C.; Blaney, D. L.; Sumner, D. Y.; Fisk, M. R.; Rapin, W.; Nachon, M.; Mangold, N.; Grotzinger, J. P.; Wiens, R. C.

    2015-12-01

    Calcium sulfate filled fractures are observed in nearly all stratigraphic units encountered by the Mars Science Laboratory (MSL) Curiosity rover. The mm-scale of veins, however, provides little evidence for emplacement style. From sols 924-949, Curiosity observed a vein rich outcrop called Garden City, which shows variation in both thickness and complexity of veins. Extensive Mastcam and MAHLI imaging was conducted across the outcrop to provide textural detail that can be related to emplacement mechanisms. Additionally, Curiosity collected geochemical data on 17 ChemCam targets and 7 APXS targets, shedding light on the composition and variety of potential vein fluids. The Garden City vein system records (1) the presence of distinct dark-toned and light-toned (calcium sulfate) mineralization, and (2) the presence of laminated, epitaxial, and brecciated fabrics that suggest multiple emplacement modes. Dark-toned mineralization is observed as erosionally resistant ridges predominantly along fracture walls. Although erosional resistance may reflect the permeability of host rock to fracture-borne fluids, at Garden City, laminated textures suggest that at least some mineralization may have occurred as fracture-fill. Light-toned mineralization often bisects dark-toned material, indicating re-use of fluid pathways. Light-toned veinlets permeate fracture walls, and the largest veins entrain host rock and dark-toned material within calcium sulfate matrix. Such brecciation indicates high forces associated with fluid expulsion. Elsewhere, linear patterns occur broadly perpendicular to fracture walls, and are interpreted to represent epitaxial crystal growth, suggesting lower flow rates and fluid flow pressures within the fracture system. Together these observations indicate multiple episodes of fluid flow in the Gale Crater system.

  6. [Mechanobiology and bone metabolism: Clinical relevance for fracture treatment].

    PubMed

    Haffner-Luntzer, M; Liedert, A; Ignatius, A

    2015-12-01

    Mechanical stimuli are known to significantly influence bone metabolism and fracture healing. Various studies have demonstrated the involvement of complex molecular mechanotransduction pathways, such as the Wnt/beta-catenin, bone morphogenetic protein (BMP) and estrogen receptor signaling pathways in mechanotransduction. Mechanotransduction is influenced by aging and the comorbidities of the patient. Pharmacological modulation of signal transduction influences bone formation and the mechanosensitivity of skeletal tissue. The combination of pharmacological and biomechanical therapies may be useful for the treatment of fractures with impaired healing.

  7. Steeply-dipping extension fractures in the Newark basin, New Jersey

    USGS Publications Warehouse

    Herman, G.C.

    2009-01-01

    Late Triassic and Early Jurassic bedrock in the Newark basin is pervasively fractured as a result of Mesozoic rifting of the east-central North American continental margin. Tectonic rifting imparted systematic sets of steeply-dipping, en ??chelon, Mode I, extension fractures in basin strata including ordinary joints and veins. These fractures are arranged in transitional-tensional arrays resembling normal dip-slip shear zones. They contributed to crustal stretching, sagging, and eventual faulting of basin rift deposits. Extension fractures display progressive linkage and spatial clustering that probably controlled incipient fault growth. They cluster into three prominent strike groups correlated to early, intermediate, and late-stage tectonic events reflecting about 50- 60?? of counterclockwise rotation of incremental stretching directions. Finite strain analyses show that extension fractures allowed the stretching of basin strata by a few percent, and these fractures impart stratigraphic dips up to a few degrees in directions opposing fracture dips. Fracture groups display three-dimensional spatial variability but consistent geometric relations. Younger fractures locally cut across and terminate against older fractures having more complex vein-cement morphologies and bed-normal folds from stratigraphic compaction. A fourth, youngest group of extension fractures occur sporadically and strike about E-W in obliquely inverted crustal blocks. A geometric analysis of overlapping fracture sets shows how fracture groups result from incremental rotation of an extending tectonic plate, and that old fractures can reactivate with oblique slip components in the contemporary, compressive stress regime. ?? 2008 Elsevier Ltd. All rights reserved.

  8. Phase field model of fluid-driven fracture in elastic media: Immersed-fracture formulation and validation with analytical solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santillán, David; Juanes, Ruben; Cueto-Felgueroso, Luis

    Propagation of fluid-driven fractures plays an important role in natural and engineering processes, including transport of magma in the lithosphere, geologic sequestration of carbon dioxide, and oil and gas recovery from low-permeability formations, among many others. The simulation of fracture propagation poses a computational challenge as a result of the complex physics of fracture and the need to capture disparate length scales. Phase field models represent fractures as a diffuse interface and enjoy the advantage that fracture nucleation, propagation, branching, or twisting can be simulated without ad hoc computational strategies like remeshing or local enrichment of the solution space. Heremore » we propose a new quasi-static phase field formulation for modeling fluid-driven fracturing in elastic media at small strains. The approach fully couples the fluid flow in the fracture (described via the Reynolds lubrication approximation) and the deformation of the surrounding medium. The flow is solved on a lower dimensionality mesh immersed in the elastic medium. This approach leads to accurate coupling of both physics. We assessed the performance of the model extensively by comparing results for the evolution of fracture length, aperture, and fracture fluid pressure against analytical solutions under different fracture propagation regimes. Thus, the excellent performance of the numerical model in all regimes builds confidence in the applicability of phase field approaches to simulate fluid-driven fracture.« less

  9. Phase field model of fluid-driven fracture in elastic media: Immersed-fracture formulation and validation with analytical solutions

    DOE PAGES

    Santillán, David; Juanes, Ruben; Cueto-Felgueroso, Luis

    2017-04-20

    Propagation of fluid-driven fractures plays an important role in natural and engineering processes, including transport of magma in the lithosphere, geologic sequestration of carbon dioxide, and oil and gas recovery from low-permeability formations, among many others. The simulation of fracture propagation poses a computational challenge as a result of the complex physics of fracture and the need to capture disparate length scales. Phase field models represent fractures as a diffuse interface and enjoy the advantage that fracture nucleation, propagation, branching, or twisting can be simulated without ad hoc computational strategies like remeshing or local enrichment of the solution space. Heremore » we propose a new quasi-static phase field formulation for modeling fluid-driven fracturing in elastic media at small strains. The approach fully couples the fluid flow in the fracture (described via the Reynolds lubrication approximation) and the deformation of the surrounding medium. The flow is solved on a lower dimensionality mesh immersed in the elastic medium. This approach leads to accurate coupling of both physics. We assessed the performance of the model extensively by comparing results for the evolution of fracture length, aperture, and fracture fluid pressure against analytical solutions under different fracture propagation regimes. Thus, the excellent performance of the numerical model in all regimes builds confidence in the applicability of phase field approaches to simulate fluid-driven fracture.« less

  10. Identifying Blocks Formed by Curbed Fractures Using Exact Arithmetic

    NASA Astrophysics Data System (ADS)

    Zheng, Y.; Xia, L.; Yu, Q.; Zhang, X.

    2015-12-01

    Identifying blocks formed by fractures is important in rock engineering. Most studies assume the fractures to be perfect planar whereas curved fractures are rarely considered. However, large fractures observed in the field are often curved. This paper presents a new method for identifying rock blocks formed by both curved and planar fractures based on the element-block-assembling approach. The curved and planar fractures are represented as triangle meshes and planar discs, respectively. In the beginning of the identification method, the intersection segments between different triangle meshes are calculated and the intersected triangles are re-meshed to construct a piecewise linear complex (PLC). Then, the modeling domain is divided into tetrahedral subdomains under the constraint of the PLC and these subdomains are further decomposed into element blocks by extended planar fractures. Finally, the element blocks are combined and the subdomains are assembled to form complex blocks. The combination of two subdomains is skipped if and only if the common facet lies on a curved fracture. In this study, the exact arithmetic is used to handle the computational errors, which may threat the robustness of the block identification program when the degenerated cases are encountered. Specifically, a real number is represented as the ratio between two integers and the basic arithmetic such as addition, subtraction, multiplication and division between different real numbers can be performed exactly if an arbitrary precision integer package is used. In this way, the exact construction of blocks can be achieved without introducing computational errors. Several analytical examples are given in this paper and the results show effectiveness of this method in handling arbitrary shaped blocks. Moreover, there is no limitation on the number of blocks in a block system. The results also show (suggest) that the degenerated cases can be handled without affecting the robustness of the identification program.

  11. Analysis of thin fractures with GPR: from theory to practice

    NASA Astrophysics Data System (ADS)

    Arosio, Diego; Zanzi, Luigi; Longoni, Laura; Papini, Monica

    2017-04-01

    Whenever we perform a GPR survey to investigate a rocky medium, being the ultimate purpose of the survey either to study the stability of a rock slope or to determine the soundness of a quarried rock block, we would like mainly to detect any fracture within the investigated medium and, possibly, to estimate the parameters of the fractures, namely thickness and filling material. In most of the practical cases, rock fracture thicknesses are very small when compared to the wavelength of the electromagnetic radiation generated by the GPR systems. In such cases, fractures are to be considered as thin beds, i.e. two interfaces whose distance is smaller than GPR resolving capability, and the reflected signal is the sum of the electromagnetic reverberation within the bed. According to this, fracture parameters are encoded in the thin bed complex response and in this work we propose a methodology based on deterministic deconvolution to process amplitude and phase information in the frequency domain to estimate fracture parameters. We first present some theoretical aspects related to thin bed response and a sensitivity analysis concerning fracture thickness and filling. Secondly, we deal with GPR datasets collected both during laboratory experiments and in the facilities of quarrying activities. In the lab tests fractures were simulated by placing materials with known electromagnetic parameters and controlled thickness in between two small marble blocks, whereas field GPR surveys were performed on bigger quarried ornamental stone blocks before they were submitted to the cutting process. We show that, with basic pre-processing and the choice of a proper deconvolving signal, results are encouraging although an ambiguity between thickness and filling estimates exists when no a-priori information is available. Results can be improved by performing CMP radar surveys that are able to provide additional information (i.e., variation of thin bed response versus offset) at the expense of acquisition effort and of more complex and tricky pre-processing sequences.

  12. Does semi-automatic bone-fragment segmentation improve the reproducibility of the Letournel acetabular fracture classification?

    PubMed

    Boudissa, M; Orfeuvre, B; Chabanas, M; Tonetti, J

    2017-09-01

    The Letournel classification of acetabular fracture shows poor reproducibility in inexperienced observers, despite the introduction of 3D imaging. We therefore developed a method of semi-automatic segmentation based on CT data. The present prospective study aimed to assess: (1) whether semi-automatic bone-fragment segmentation increased the rate of correct classification; (2) if so, in which fracture types; and (3) feasibility using the open-source itksnap 3.0 software package without incurring extra cost for users. Semi-automatic segmentation of acetabular fractures significantly increases the rate of correct classification by orthopedic surgery residents. Twelve orthopedic surgery residents classified 23 acetabular fractures. Six used conventional 3D reconstructions provided by the center's radiology department (conventional group) and 6 others used reconstructions obtained by semi-automatic segmentation using the open-source itksnap 3.0 software package (segmentation group). Bone fragments were identified by specific colors. Correct classification rates were compared between groups on Chi 2 test. Assessment was repeated 2 weeks later, to determine intra-observer reproducibility. Correct classification rates were significantly higher in the "segmentation" group: 114/138 (83%) versus 71/138 (52%); P<0.0001. The difference was greater for simple (36/36 (100%) versus 17/36 (47%); P<0.0001) than complex fractures (79/102 (77%) versus 54/102 (53%); P=0.0004). Mean segmentation time per fracture was 27±3min [range, 21-35min]. The segmentation group showed excellent intra-observer correlation coefficients, overall (ICC=0.88), and for simple (ICC=0.92) and complex fractures (ICC=0.84). Semi-automatic segmentation, identifying the various bone fragments, was effective in increasing the rate of correct acetabular fracture classification on the Letournel system by orthopedic surgery residents. It may be considered for routine use in education and training. III: prospective case-control study of a diagnostic procedure. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  13. Females report higher postoperative pain scores than males after ankle surgery.

    PubMed

    Storesund, Anette; Krukhaug, Yngvar; Olsen, Marit Vassbotten; Rygh, Lars Jørgen; Nilsen, Roy M; Norekvål, Tone M

    2016-07-01

    The majority of patients experience moderate-to-intense pain following ankle surgery. Early, adequate treatment of postoperative pain is desirable for optimal pain relief, which in turn may facilitate optimal pulmonary function, normal respiration pattern, rehabilitation and prevention of a chronic pain condition. In this retrospective study, we aimed to identify possible predictors of moderate-to-intense postoperative pain while in the Post Anaesthesia Care Unit (PACU) in patients operated for ankle fractures. Social demographics and clinical characteristics from admission throughout the stay in the PACU were collected from the hospital patient record system in retrospect. Pain was assessed using a Visual Analogue Scale (VAS) or a verbal Numeric Rating Scale (vNRS). A VAS/vNRS score 4-6 was classified as moderate and 7-10 as intense pain. Other factors which were investigated were time from ankle fracture to surgery, anaesthetic procedure, pre-, per- and postoperative medical treatment, radiological classification, complexity of fracture, operative technique, and time using tourniquet procedure. Data from 336 patients who underwent surgery to repair an ankle fracture between January 2009 and December 2010 were analysed. None of the following variables had a statistically significant effect on pain; age, weight, smoking, timeframe from fracture to operation, type of anaesthesia, opioids given peroperatively, complexity of the fracture, operation technique or tourniquet inflation procedure. Female sex predicted moderate-to-intense postoperative pain in the PACU with odds ratio 2.31 (95% confidence interval 1.39-3.86), P=0.001. As far as we know, this is the first study to show a sex difference in reporting pain in the first hours after surgery for ankle fracture. Female patients operated for ankle fracture report higher pain-intensity-score than male patients while in the PACU. Our findings suggest that treatment strategies to prevent high peaks of pain should particularly target women operated for an ankle fracture. Copyright © 2016 The Author(s). Published by Elsevier B.V. All rights reserved.

  14. Nonlinear Fluid Migration Patterns in Fractured Reservoirs due to Stress-Pressure Coupling induced Changes in Reservoir Permeabilities

    NASA Astrophysics Data System (ADS)

    Annewandter, R.; Geiger, S.; Main, I. G.

    2011-12-01

    Sustainable storage of carbon dioxide (CO2) requires a thorough understanding of injection induced pressure build-up and its effects on the storage formation's integrity, since it determines the cap rock's sealing properties as well as the total storable amount of carbon dioxide. Fractures are abundant in the subsurface and difficult to detect due to their subseismic characteristic. If present in the cap during injection, they can be primary pathways for CO2 leakage. The North Sea is considered as Europe's most important carbon dioxide storage area. However, almost all of the potential storage formations have been exposed to post-glacial lithospheric flexure, possibly causing the generation of new fracture networks in the overburden whilst rebounding. Drawing upon, fast carbon dioxide uprise can be facilitated due to opening of fractures caused by changes in the stress field over time. The overall effective permeability, and hence possible leakage rates, of a fractured storage formation is highly sensitive to the fracture aperture which itself depends on the far field and in situ stress field. For this reason, our in-house general purpose reservoir simulator Complex System Modeling Platform (CSMP++) has been expanded, which is particularly designed to simulate multiphase flow on fractured porous media. It combines finite element (FE) and finite volume (FV) methods on mixed-dimensional hybrid-element meshes. The unstructured FE-FV based scheme allows us to model complex geological structures, such as fractures, at great detail. The simulator uses a compositional model for NaCl-H2O-CO2-systems for compressible fluids for computing thermophysical properties as a function of formation pressure and temperature. A fixed stress-split sequential procedure is being used to calculate coupled fluid flow and geomechanics. Numerical proof of concept studies will be presented showing the impact of fracture opening and closure on fluid migration patterns due to coupled stress-pressure induced changes in effective permeabilities.

  15. Fracture network created by 3D printer and its validation using CT images

    NASA Astrophysics Data System (ADS)

    Suzuki, A.; Watanabe, N.; Li, K.; Horne, R. N.

    2017-12-01

    Understanding flow mechanisms in fractured media is essential for geoscientific research and geological development industries. This study used 3D printed fracture networks in order to control the properties of fracture distributions inside the sample. The accuracy and appropriateness of creating samples by the 3D printer was investigated by using a X-ray CT scanner. The CT scan images suggest that the 3D printer is able to reproduce complex three-dimensional spatial distributions of fracture networks. Use of hexane after printing was found to be an effective way to remove wax for the post-treatment. Local permeability was obtained by the cubic law and used to calculate the global mean. The experimental value of the permeability was between the arithmetic and geometric means of the numerical results, which is consistent with conventional studies. This methodology based on 3D printed fracture networks can help validate existing flow modeling and numerical methods.

  16. Temporary Fixation Using a Long Femoral-tibial Nail to Treat a Displaced Medial Tibial Plateau Fracture in a 90-year-old Patient: A Case Report

    PubMed Central

    Batta, V; Sinha, S; Trompeter, A

    2017-01-01

    Introduction: Tibial plateau fractures are complex injuries in the elderly population. When traditional methods of fixation are not suitable, an alternative method needs to be chosen for a favorable outcome. We demonstrate a previously undescribed treatment for displaced tibial plateau fractures in the very elderly with poor soft-tissue integrity. Case Report: A 90-year-old woman suffered an open, Gustilo Grade IIIA, displaced fracture of the tibial plateau. An intramedullary knee arthrodesis, the femoral-tibial nail was used to temporarily stabilize her fracture. She was able to weight bear immediately postfixation. Conclusion: A long femoral-tibial nail allows favorable fracture and soft tissue healing, ease of nursing and immediate full weight-bearing. It shows good promise and should be considered as a management option when traditional methods are not applicable in select patients. PMID:29181350

  17. Temporary Fixation Using a Long Femoral-tibial Nail to Treat a Displaced Medial Tibial Plateau Fracture in a 90-year-old Patient: A Case Report.

    PubMed

    Batta, V; Sinha, S; Trompeter, A

    2017-01-01

    Tibial plateau fractures are complex injuries in the elderly population. When traditional methods of fixation are not suitable, an alternative method needs to be chosen for a favorable outcome. We demonstrate a previously undescribed treatment for displaced tibial plateau fractures in the very elderly with poor soft-tissue integrity. A 90-year-old woman suffered an open, Gustilo Grade IIIA, displaced fracture of the tibial plateau. An intramedullary knee arthrodesis, the femoral-tibial nail was used to temporarily stabilize her fracture. She was able to weight bear immediately postfixation. A long femoral-tibial nail allows favorable fracture and soft tissue healing, ease of nursing and immediate full weight-bearing. It shows good promise and should be considered as a management option when traditional methods are not applicable in select patients.

  18. Repair of a pediatric bilateral condylar and symphyseal fracture using a transfacial Steinman pin.

    PubMed

    Grow, Jacob N; Flores, Roberto L; Tholpady, Sunil S

    2014-01-01

    The proper management of complex pediatric mandibular fractures remains a topic of debate because of the relatively uncommon presentation of these fractures, combined with concerns related with deciduous teeth, tooth buds, and growth inhibition. In this current study, we present a novel approach to the repair of bilateral condylar fractures with concomitant symphyseal fracture in a 4-year-old girl. Manual closed reduction was first obtained, followed by placement of a transfacial Steinman pin through the angles of the mandible and placement of circummandibular wires. Maxillomandibular fixation remained for 2 weeks and the Steinman pin was removed after 11 weeks. At 3 months of postsurgical follow-up, the patient displayed class I occlusion, facial symmetry, full range of jaw motion, and absence of deviation or pain on full oral excursion. Radiographic findings also revealed complete resolution of the symphyseal fracture with appropriate condylar healing and alignment.

  19. Niobrara Discrete Fracture Network: From Outcrop Surveys to Subsurface Reservoir Models

    NASA Astrophysics Data System (ADS)

    Grechishnikova, Alena

    Heterogeneity of an unconventional reservoir is one of the main factors affecting production. Well performance depends on the size and efficiency of the interconnected fracture "plumbing system", as influenced by multistage hydraulic fracturing. A complex, interconnected natural fracture network can significantly increase the size of stimulated reservoir volume, provide additional surface area contact and enhance permeability. In 2013 the Reservoir Characterization Project (RCP) at the Colorado School of Mines began Phase XV to study Niobrara shale reservoir management. Anadarko Petroleum Corporation and RCP jointly acquired time-lapse multicomponent seismic data in Wattenberg Field, Denver Basin. Anadarko also provided RCP with a regional 3D seismic survey and a rich well dataset. The purpose of this study is to characterize the natural fracture patterns occurring in the unconventional Niobrara reservoir and to determine the drivers that influenced fracture trends and distributions. The findings are integrated into a reservoir model though DFN (Discrete Fracture Network) for further prediction of reservoir performance using reservoir simulations. Aiming to better understand the complexity of the natural fracture system I began my fracture analysis work at an active mine site that provides a Niobrara exposure. Access to a "fresh" outcrop surface created a perfect natural laboratory. Ground-based LIDAR and photogrammetry facilitated construction of a geological model and a DFN model for the mine site. The work was carried into subsurface where the information gained served to improve reservoir characterization at a sub-seismic scale and can be used in well planning. I then embarked on a challenging yet essential task of outcrop-to-subsurface data calibration and application to RCP's Wattenberg Field study site. In this research the surface data was proven to be valid for comparative use in the subsurface. The subsurface fracture information was derived from image logs run within the horizontal wellbores and augmented with microseismic data. Limitations of these datasets included the potential to induce biased interpretations; but the data collected during the outcrop study aided in removing the bias. All four fracture sets observed at the quarry were also interpreted in the subsurface; however there was a limitation on statistical validity for one of the four sets due to a low frequency of observed occurrence potentially caused by wellbore orientation. Microseismic data was used for identification of one of the reactivated natural fracture sets. An interesting phenomenon observed in the microseismic data trends was the low frequency of event occurrence within dense populations of open natural fracture swarms suggesting that zones of higher natural fracture intensities are capable of absorbing and transmitting energy resulting in lower levels of microseismicity. Thus currently open natural fractures could be challenging to detect using microseismic. Through this study I identified a significant variability in fracture intensity at a localized scale due to lithological composition and structural features. The complex faulting styles observed at the outcrop were utilized as an analog and verified by horizontal well log data and seismic volume interpretations creating a high resolution structural model for the subsurface. A lithofacies model was developed based on the well log, core, and seismic inversion analysis. These models combined served to accurately distribute fracture intensity information within the geological model for further use in DFN. As a product of this study, a workflow was developed to aid in fracture network model creation allowing for more intelligent decisions to be made during well planning and completion optimization aiming to improve recovery. A high resolution integrated discrete fracture network model serves to advance dynamic reservoir characterization in the subsurface at a sub-seismic scale resulting in improved reservoir characterization.

  20. Statistical Tools And Artificial Intelligence Approaches To Predict Fracture In Bulk Forming Processes

    NASA Astrophysics Data System (ADS)

    Di Lorenzo, R.; Ingarao, G.; Fonti, V.

    2007-05-01

    The crucial task in the prevention of ductile fracture is the availability of a tool for the prediction of such defect occurrence. The technical literature presents a wide investigation on this topic and many contributions have been given by many authors following different approaches. The main class of approaches regards the development of fracture criteria: generally, such criteria are expressed by determining a critical value of a damage function which depends on stress and strain paths: ductile fracture is assumed to occur when such critical value is reached during the analysed process. There is a relevant drawback related to the utilization of ductile fracture criteria; in fact each criterion usually has good performances in the prediction of fracture for particular stress - strain paths, i.e. it works very well for certain processes but may provide no good results for other processes. On the other hand, the approaches based on damage mechanics formulation are very effective from a theoretical point of view but they are very complex and their proper calibration is quite difficult. In this paper, two different approaches are investigated to predict fracture occurrence in cold forming operations. The final aim of the proposed method is the achievement of a tool which has a general reliability i.e. it is able to predict fracture for different forming processes. The proposed approach represents a step forward within a research project focused on the utilization of innovative predictive tools for ductile fracture. The paper presents a comparison between an artificial neural network design procedure and an approach based on statistical tools; both the approaches were aimed to predict fracture occurrence/absence basing on a set of stress and strain paths data. The proposed approach is based on the utilization of experimental data available, for a given material, on fracture occurrence in different processes. More in detail, the approach consists in the analysis of experimental tests in which fracture occurs followed by the numerical simulations of such processes in order to track the stress-strain paths in the workpiece region where fracture is expected. Such data are utilized to build up a proper data set which was utilized both to train an artificial neural network and to perform a statistical analysis aimed to predict fracture occurrence. The developed statistical tool is properly designed and optimized and is able to recognize the fracture occurrence. The reliability and predictive capability of the statistical method were compared with the ones obtained from an artificial neural network developed to predict fracture occurrence. Moreover, the approach is validated also in forming processes characterized by a complex fracture mechanics.

  1. Experimental investigation of CNT effect on curved beam strength and interlaminar fracture toughness of CFRP laminates

    NASA Astrophysics Data System (ADS)

    Arca, M. A.; Coker, D.

    2014-06-01

    High mechanical properties and light weight structures of composite materials and advances in manufacturing processes have increased the use of composite materials in the aerospace and wind energy industries as a primary load carrying structures in complex shapes. However, use of composite materials in complex geometries such as L-shaped laminates creates weakness at the radius which causes delamination. Carbon nanotubes (CNTs) is preferred as a toughening materials in composite matrices due to their high mechanical properties and aspect ratios. However, effect of CNTs on curved beam strength (CBS) is not investigated in literature comprehensively. The objective of this study is to investigate the effect of CNT on Mode I and Mode II fracture toughness and CBS. L-shaped beams are fabric carbon/epoxy composite laminates manufactured by hand layup technique. Curved beam composite laminates were subjected to four point bending loading according to ASTM D6415/D6415M-06a. Double cantilever beam (DCB) tests and end notch flexure (ENF) tests were conducted to determine mode-I and mode-II fracture toughness, respectively. Preliminary results show that 3% CNT addition to the resin increased the mode-I fracture toughness by %25 and mode-II fracture toughness by %10 compared to base laminates. In contrast, no effect on curved beam strength was found.

  2. The Influence of Socioeconomic Factors on the Epidemiology of Maxillofacial Fractures in Southern Italy.

    PubMed

    Sbordone, Carolina; Barca, Ida; Petrocelli, Marzia; Dell'Aversana Orabona, Giovanni; Vaira, Luigi Angelo; Colangeli, Walter; Cristofaro, Maria Giulia; Giudice, Mario; Giudice, Amerigo; Cassandro, Francesco Maria; Attanasi, Federica; Iaconetta, Giorgio; Califano, Luigi

    2018-05-15

    Maxillofacial fractures represent a serious public health problem. Their epidemiology is extremely variable and its analysis is crucial to establish effective treatment and prevention of these injuries. The aim of this multicentric retrospective study was to analyze causes, demographics, incidence, characteristics of 987 patients diagnosed with maxillofacial trauma between 2011 and 2015 at Complex Operative Unit of Maxillofacial Surgery of Federico II University of Naples and Magna Graecia University of Catanzaro, Italy; 657 male and 310 female patients were admitted in the study. The most frequently observed fracture involved the mandible (399 patients, 35.4%), followed by zygomatic complex (337 patients, 29.9%), orbital walls (160 patients, 14.2%), and nasal bones (129 patients, 11.4%). The most frequent cause of fracture was assaults (30.4%), followed by road traffic injuries (27.2%), falls (23.2%), sport accidents (15.4%), and others causes (2.6%). Significant variations of etiology have been detected between the 2 hospitals in relationship with different migration flow trends and cultural and socioeconomic features. Epidemiological analysis of maxillofacial fractures is crucial to identify the trauma burden and to help in developing a more efficient system to plan resource allocation and to deliver care and preventive measures establishing clinical and research priorities for effective treatment and prevention of these injuries.

  3. Tectonic controls on large landslide complex: Williams Fork Mountains near Dillon, Colorado

    USGS Publications Warehouse

    Kellogg, K.S.

    2001-01-01

    An extensive (~ 25 km2) landslide complex covers a large area on the west side of the Williams Fork Mountains in central Colorado. The complex is deeply weathered and incised, and in most places geomorphic evidence of sliding (breakaways, hummocky topography, transverse ridges, and lobate distal zones) are no longer visible, indicating that the main mass of the slide has long been inactive. However, localized Holocene reactivation of the landslide deposits is common above the timberline (at about 3300 m) and locally at lower elevations. Clasts within the complex, as long as several tens of meters, are entirely of crystalline basement (Proterozoic gneiss and granitic rocks) from the hanging wall of the Laramide (Late Cretaceous to Early Tertiary), west-directed Williams Range thrust, which forms the western structural boundary of the Colorado Front Range. Late Cretaceous shale and sandstone compose most footwall rocks. The crystalline hanging-wall rocks are pervasively fractured or shattered, and alteration to clay minerals is locally well developed. Sackung structures (trenches or small-scale grabens and upslope-facing scarps) are common near the rounded crest of the range, suggesting gravitational spreading of the fractured rocks and oversteepening of the mountain flanks. Late Tertiary and Quaternary incision of the Blue River Valley, just west of the Williams Fork Mountains, contributed to the oversteepening. Major landslide movement is suspected during periods of deglaciation when abundant meltwater increased pore-water pressure in bedrock fractures. A fault-flexure model for the development of the widespread fracturing and weakening of the Proterozoic basement proposes that the surface of the Williams Range thrust contains a concave-downward flexure, the axis of which coincides approximately with the contact in the footwall between Proterozoic basement and mostly Cretaceous rocks. Movement of brittle, hanging-wall rocks through the flexure during Laramide deformation pervasively fractured the hanging-wall rocks. ?? 2001 Elsevier Science B.V. All rights reserved.

  4. One Hundred Ninety-five Cases of High-voltage Electric Injury

    DTIC Science & Technology

    2005-08-01

    that level; and T4 to T5 paraplegia, secondary to fractures of T4 to T7. In 3 cases, frac- tures were not present: one case of a T11 to T12 sensory ...problems, including fractures, neurological inju- ries, ocular injuries, and complex reconstructive and re- habilitative needs, underscores the

  5. Fracture Mechanical Analysis of Open Cell Ceramic Foams Under Thermal Shock Loading

    NASA Astrophysics Data System (ADS)

    Settgast, C.; Abendroth, M.; Kuna, M.

    2016-11-01

    Ceramic foams made by replica techniques containing sharp-edged cavities, which are potential crack initiators and therefore have to be analyzed using fracture mechanical methods. The ceramic foams made of novel carbon bonded alumina are used as filters in metal melt filtration applications, where the filters are exposed to a thermal shock. During the casting process the filters experience a complex thermo-mechanical loading, which is difficult to measure. Modern numerical methods allow the simulation of such complex processes. As a simplified foam structure an open Kelvin cell is used as a representative volume element. A three-dimensional finite element model containing realistic sharp-edged cavities and three-dimensional sub-models along these sharp edges are used to compute the transient temperature, stress and strain fields at the Kelvin foam. The sharp edges are evaluated using fracture mechanical methods like the J-integral technique. The results of this study describe the influence of the pore size, relative density of the ceramic foam, the heat transfer and selected material parameters on the fracture mechanical behaviour.

  6. Ipsilateral Closed Clavicle and Scapular spine Fracture with Acromioclavicular Joint Disruption.

    PubMed

    Kembhavi, Raghavendra S; James, Boblee

    2015-01-01

    Injuries around shoulder and clavicle are quite common. Injuries involving lateral end of clavicle involving acromioclavicular joints are commoner injuries. In this rare injury, we report about a case involving clavicle and scapular spine fracture with acromioclavicular disruption which has never been described in English literature as per our knowledge. A patient with closed clavicle and scapular spine fracture with acromioclavicular joint disruption was treated with open reduction and internal fixation of clavicle and scapular spine as a staged procedures. Six months post operatively, patient had excellent functional recovery with near full range of movements. Though rare complex injury, clavicle fracture with scapular spine fracture with acromioclavicular disruption, when managed properly with good physiotherapy protocol post operatively will result in good clinical and functional outcome.

  7. Microseismic and deformation imaging of hydraulic fracture growth and geometry in the C sand interval, GRI/DOE M-Site project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warpinski, N.R.; Uhl, J.E.; Engler, B.P.

    Six hydraulic-fracture injections into a fluvial sandstone at a depth of 4300 ft were monitored with multi-level tri-axial seismic receivers in two wells and an inclinometer array in one well, resulting in maps of the growth and final geometry of each fracture injection. These diagnostic images show the progression of height and length growth with fluid volume, rate and viscosity. Complexities associated with shut downs and high treatment pressures can be observed. Validation of the seismic geometry was made with the inclinometers and diagnostic procedures in an intersecting well. Fracture information related to deformation, such as fracture closure pressure, residualmore » widths, and final prop distribution, were obtained from the inclinometer data.« less

  8. A Cost-Effectiveness Analysis of Reverse Total Shoulder Arthroplasty versus Hemiarthroplasty for the Management of Complex Proximal Humeral Fractures in the Elderly.

    PubMed

    Osterhoff, Georg; O'Hara, Nathan N; D'Cruz, Jennifer; Sprague, Sheila A; Bansback, Nick; Evaniew, Nathan; Slobogean, Gerard P

    2017-03-01

    There is ongoing debate regarding the optimal surgical treatment of complex proximal humeral fractures in elderly patients. To evaluate the cost-effectiveness of reverse total shoulder arthroplasty (RTSA) compared with hemiarthroplasty (HA) in the management of complex proximal humeral fractures, using a cost-utility analysis. On the basis of data from published literature, a cost-utility analysis was conducted using decision tree and Markov modeling. A single-payer perspective, with a willingness-to-pay (WTP) threshold of Can$50,000 (Canadian dollars), and a lifetime time horizon were used. The incremental cost-effectiveness ratio (ICER) was used as the study's primary outcome measure. In comparison with HA, the incremental cost per quality-adjusted life-year gained for RTSA was Can$13,679. One-way sensitivity analysis revealed the model to be sensitive to the RTSA implant cost and the RTSA procedural cost. The ICER of Can$13,679 is well below the WTP threshold of Can$50,000, and probabilistic sensitivity analysis demonstrated that 92.6% of model simulations favored RTSA. Our economic analysis found that RTSA for the treatment of complex proximal humeral fractures in the elderly is the preferred economic strategy when compared with HA. The ICER of RTSA is well below standard WTP thresholds, and its estimate of cost-effectiveness is similar to other highly successful orthopedic strategies such as total hip arthroplasty for the treatment of hip arthritis. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  9. Comparison of deformation mechanics for two different carbonates: oolitic limestone and laminites

    NASA Astrophysics Data System (ADS)

    Zihms, Stephanie; Lewis, Helen; Couples, Gary; Hall, Stephen; Somerville, Jim

    2016-04-01

    Carbonate rocks form under a range of conditions which leads to a diverse rock group. Even though carbonates are overall mineralogically simple, the solid-space distribution ranges from simple compositions such as oolitic limestones to highly complex networks of pores and solids as seen in coquinas. Their fundamental mechanical behaviour has been identified to be like clastic rocks (Vajdova 2004, Brantut, Heap et al. 2014). However it is very likely that this observation is not true for more complex carbonates. Triaxial tests were performed on cylindrical samples of two different carbonates; a) oolitic limestone (Bicqueley quarry, France) and b) laminite (Ariripe basin, Brazil). The samples were deformed under confining pressures of 8, 12 and 20MPa, and 20, 30 and 40MPa, respectively. All tests were stopped as soon as peak load was observed to preserve as many deformation characteristics as possible. Photographs of the samples were taken before and after deformation to allow surface analysis of deformation features. Additionally, samples were analysed post-deformation with X-ray tomography (XRT) (using the Zeiss XRadia XRM 520 at the 4D Imaging Lab at Lund University). The 3D tomography images represent the post-deformation samples' density distribution, allowing detailed, non-destructive, 3D analysis of the deformation features that developed in the triaxial testing, including the complex geometries and interactions of fractures, deformation bands and sedimentary layering. They also provide an insight into the complexity of deformation features produced due to the carbonate response. Initial results show that the oolitic limestone forms single shear bands almost the length of the sample, exhibiting similar characteristics to sandstones deformed under similar conditions. These features are observed for all three applied loads. The laminate sample deformed at the lowest confining pressure exhibits compactive features. However, the laminite samples deformed at the two higher confining pressures both show highly complex fracture networks comprising open fractures and fracture propagation. This suggests that the laminate changes from compactive to dilational responses over the selected confining conditions. The XRT analysis indicates that a more complex fracture distribution could be linked to rock component properties e.g. grain size and composition. For the laminite these are variable with the layers. This is in agreement with field observations of laminite microfabrics (Calvo, Rodriguez-Pascua et al. 1998). Additionally, the typical grain size of the laminate (μm) is much smaller than the oolitic limestone (mm), which suggests that fracture network complexity can also be linked to bulk system complexity i.e. pore & grain network. These deformation experiments show that, as previously observed, oolitic limestones seem to behave similarly to sandstones. However this observation is not true for laminites and it is very likely that more complex carbonates will develop even more complicated deformation behaviour. It is therefore necessary to systematically test different carbonate rocks to understand the impact of geometry and composition, as well as the interplay with the pore network. Brantut, N., et al. (2014). Journal of Geophysical Research: Solid Earth 119(7): 5444-5463. Calvo, J. P., et al. (1998). Sedimentology 45: 279-292. Vajdova, V. (2004). Journal of Geophysical Research 109(B5).

  10. Spatial arrangement of faults and opening-mode fractures

    NASA Astrophysics Data System (ADS)

    Laubach, S. E.; Lamarche, J.; Gauthier, B. D. M.; Dunne, W. M.; Sanderson, David J.

    2018-03-01

    Spatial arrangement is a fundamental characteristic of fracture arrays. The pattern of fault and opening-mode fracture positions in space defines structural heterogeneity and anisotropy in a rock volume, governs how faults and fractures affect fluid flow, and impacts our understanding of the initiation, propagation and interactions during the formation of fracture patterns. This special issue highlights recent progress with respect to characterizing and understanding the spatial arrangements of fault and fracture patterns, providing examples over a wide range of scales and structural settings. Five papers describe new methods and improvements of existing techniques to quantify spatial arrangement. One study unravels the time evolution of opening-mode fracture spatial arrangement, which are data needed to compare natural patterns with progressive fracture growth in kinematic and mechanical models. Three papers investigate the role of evolving diagenesis in localizing fractures by mechanical stratigraphy and nine discuss opening-mode fracture spatial arrangement. Two papers show the relevance of complex cluster patterns to unconventional reservoirs through examples of fractures in tight gas sandstone horizontal wells, and a study of fracture arrangement in shale. Four papers demonstrate the roles of folds in fracture localization and the development spatial patterns. One paper models along-fault friction and fluid pressure and their effects on fault-related fracture arrangement. Contributions address deformation band patterns in carbonate rocks and fault size and arrangement above a detachment fault. Three papers describe fault and fracture arrangements in basement terrains, and three document fracture patterns in shale. This collection of papers points toward improvement in field methods, continuing improvements in computer-based data analysis and creation of synthetic fracture patterns, and opportunities for further understanding fault and fracture attributes in the subsurface through coupled spatial, size, and pattern analysis.

  11. Contaminant transport in fractured rocks with significant matrix permeability, using natural fracture geometries

    NASA Astrophysics Data System (ADS)

    Odling, Noelle E.; Roden, Julie E.

    1997-09-01

    Some results from numerical models of flow and contaminant transport in fractured permeable rocks, where fractures are more conductive than rock matrix, are described. The 2D flow field in the fractured and permeable rock matrix is calculated using a finite difference, 'conductance mesh' method, and the contaminant transport is simulated by particle tracking methods using an advection-biased, random walk technique. The model is applied to simulated and naturally occurring fracture patterns. The simulated pattern is an en echelon array of unconnected fractures, as an example of a common, naturally occurring fracture geometry. Two natural fracture patterns are used: one of unconnected, sub-parallel fractures and one with oblique fracture sets which is well connected. Commonly occurring matrix permeability and fracture aperture values are chosen. The simulations show that the presence of fractures creates complex and heterogeneous flow fields and contaminant distribution in the permeable rock matrix. The modelling results have shown that some effects are non-intuitive and therefore difficult to foresee without the help of a model. With respect to contaminant transport rates and plume heterogeneity, it was found that fracture connectivity (crucial when the matrix is impermeable) can play a secondary role to fracture orientation and density. Connected fracture systems can produce smooth break-through curves of contaminants summed over, for example, a bore-hole length, whereas in detail the contaminant plume is spatially highly heterogeneous. Close to a constant-pressure boundary (e.g. an extraction bore-hole), flow and contaminants can be channelled by fractures. Thus observations at a bore-hole may suggest that contaminants are largely confined to the fracture system, when, in fact, significant contamination resides in the matrix.

  12. High resolution digital elevation modelling from TLS and UAV campaign reveals structural complexity at the 2014/15 Holuhraun eruption site, Iceland

    NASA Astrophysics Data System (ADS)

    Müller, Daniel; Walter, Thomas R.; Schöpa, Anne; Witt, Tanja; Steinke, Bastian; Gudmundsson, Magnús T.; Dürig, Tobias

    2017-07-01

    Fissure eruptions are commonly linked to magma dikes at depth, associated with elastic and anelastic surface deformation. Elastic deformation is well described by subsidence above, uplift and lateral widening perpendicular to the dike plane. The anelastic part is associated with the formation of a graben, bordered by graben parallel faults that might express as sets of fractures at the surface. Additionally secondary structures, like push ups, bends and step overs yield information about the deforming domain. The formation of such structures associated with fissure eruptions, however, is barely preserved in nature because of the rapid erosion or sediment coverage. Therefore, simple normal fault displacements are commonly assumed at dikes. At the 2014/2015 Holuhraun eruption sites (Iceland), evidence is increasing that the developing fractures are showing variations in their displacement modes. In an attempt to investigate these variations, a fieldwork mapping project combining Terrestrial Laser Scanning (TLS) and Unmanned Aerial Vehicle (UAV) based aerophoto analysis was realized. From this data, we generated locally high resolution Digital Elevation Models (DEMs) and a structural map that allows for identification of kinematic indicators and assessing particularities of the observed structures. We identified 315 fracture segments from satellite data. For single segments we measured strike directions including the amount of opening and opening angles, indicating that many of the measured fractures show transtensional dislocations. Out of these, 81 % are showing significant left-lateral slip, only 17% right-lateral slip and 2% pure tensile opening. We show that local complexities in the fracture traces and geometries are closely related to variations in the transtensional opening direction. Moreover, we identified local changes in fracture azimuths and offsets close to eruption sites, which we speculate to be associated with geometrical changes in the magma feeder itself. Results highlight that opening of fractures associated with an erupting fissure commonly show transtensional modes having both, left-lateral and right-lateral slip, with important implications for interpreting the expression of surface structures at rift zones elsewhere. Results further highlight the great value of UAV based high resolution data to contribute to the integrity of observations of structural complexities at local geologic events.

  13. Elevated temperature crack growth in advanced powder metallurgy aluminum alloys

    NASA Technical Reports Server (NTRS)

    Porr, William C., Jr.; Gangloff, Richard P.

    1990-01-01

    Rapidly solidified Al-Fe-V-Si powder metallurgy alloy FVS0812 is among the most promising of the elevated temperature aluminum alloys developed in recent years. The ultra fine grain size and high volume fraction of thermally stable dispersoids enable the alloy to maintain tensile properties at elevated temperatures. In contrast, this alloy displays complex and potentially deleterious damage tolerant and time dependent fracture behavior that varies with temperature. J-Integral fracture mechanics were used to determine fracture toughness (K sub IC) and crack growth resistance (tearing modulus, T) of extruded FVS0812 as a function of temperature. The alloy exhibits high fracture properties at room temperature when tested in the LT orientation, due to extensive delamination of prior ribbon particle boundaries perpendicular to the crack front. Delamination results in a loss of through thickness constraint along the crack front, raising the critical stress intensity necessary for precrack initiation. The fracture toughness and tensile ductility of this alloy decrease with increasing temperature, with minima observed at 200 C. This behavior results from minima in the intrinsic toughness of the material, due to dynamic strain aging, and in the extent of prior particle boundary delaminations. At 200 C FVS0812 fails at K levels that are insufficient to cause through thickness delamination. As temperature increases beyond the minimum, strain aging is reduced and delamination returns. For the TL orientation, K (sub IC) decreased and T increased slightly with increasing temperature from 25 to 316 C. Fracture in the TL orientation is governed by prior particle boundary toughness; increased strain localization at these boundaries may result in lower toughness with increasing temperature. Preliminary results demonstrate a complex effect of loading rate on K (sub IC) and T at 175 C, and indicate that the combined effects of time dependent deformation, environment, and strain aging may play a role. Fractography showed that microvoid coalescence was the microscopic mode of fracture in FVS0812 under all testing conditions. However, the nature of the microvoids varied with test temperature and loading rate, and is complex for the fine grain and dipersoid sizes of FVS0812.

  14. Postero-medial approach for complex tibial plateau injuries with a postero-medial or postero-lateral shear fragment.

    PubMed

    Berber, Reshid; Lewis, Charlotte P; Copas, David; Forward, Daren P; Moran, Christopher G

    2014-04-01

    This study demonstrates the utility of a modified postero-medial surgical approach to the knee in treating a series of patients with complex tibial plateau injuries with associated postero-medial and postero-lateral shear fractures. Posterior coronal shear fractures are underappreciated and their clinical relevance has recently been characterised. Less-invasive surgery and indirect reduction techniques are inadequate for treating these coronal plane fractures. Our approach includes an inverted 'L'-shaped incision situated within the posterior flexor knee crease, followed by the retraction or incision of the medial head of the gastrocnemius tendon, while protecting the neurovascular structures. This provides a more extensile exposure, as far as the postero-lateral corner, than previously described. Our case series included eight females and eight males. The average age was 53 years. The majority of these injuries were sustained through high-energy trauma. All patients' fractures were classified as Schatzker grade 4, or above, with a postero-medial split depression. Eight patients had associated postero-lateral corner fractures. Two were open, two had vascular compromise and one had neurological injury. The average time to surgery was 6.4 days (range 0-12), operative time 142 min (range 76-300) and length of stay 17 days (range 7-46). A total of 11 patients were treated using the postero-medial approach alone and in five the treatment was combined with an antero-lateral approach. Two patients suffered a reduced range of movement requiring manipulation and physiotherapy, and three patients had a 5-degree fixed flexion deformity. Two patients developed superficial wound infections treated with antibiotics alone. Anatomical reduction and fracture union was achieved in 15 patients. These are complex fractures to treat, and our modified posterior approach allows direct reduction and optimal positioning of plates to act as buttress devices. It can be extended across the midline to the postero-lateral corner and also allows excellent exposure of the popliteal vessels should concurrent vascular repair be required. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. In situ grain fracture mechanics during uniaxial compaction of granular solids

    NASA Astrophysics Data System (ADS)

    Hurley, R. C.; Lind, J.; Pagan, D. C.; Akin, M. C.; Herbold, E. B.

    2018-03-01

    Grain fracture and crushing are known to influence the macroscopic mechanical behavior of granular materials and be influenced by factors such as grain composition, morphology, and microstructure. In this paper, we investigate grain fracture and crushing by combining synchrotron x-ray computed tomography and three-dimensional x-ray diffraction to study two granular samples undergoing uniaxial compaction. Our measurements provide details of grain kinematics, contacts, average intra-granular stresses, inter-particle forces, and intra-grain crystal and fracture plane orientations. Our analyses elucidate the complex nature of fracture and crushing, showing that: (1) the average stress states of grains prior to fracture vary widely in their relation to global and local trends; (2) fractured grains experience inter-particle forces and stored energies that are statistically higher than intact grains prior to fracture; (3) fracture plane orientations are primarily controlled by average intra-granular stress and contact fabric rather than the orientation of the crystal lattice; (4) the creation of new surfaces during fracture accounts for a very small portion of the energy dissipated during compaction; (5) mixing brittle and ductile grain materials alters the grain-scale fracture response. The results highlight an application of combined x-ray measurements for non-destructive in situ analysis of granular solids and provide details about grain fracture that have important implications for theory and modeling.

  16. Early or delayed surgical treatment in compound limb fractures due to high velocity missile injuries: a 5-year retrospective study from Medical City in Baghdad.

    PubMed

    Al-Hilli, Ali Bakir; Salih, Dheyaa Saeed

    2010-01-01

    Compound limb fractures due to high-velocity missiles are complex and usually associated with multiple other injuries. These can occur in both military and civilian settings. High-velocity missiles are presently used by terrorists worldwide. Early surgical debridement and skeletal fixation are the gold standards in managing these injuries, but data supporting these recommendations are lacking. Our aim was to determine the relationship between time (the time of injury to the time of surgical treatment) and the rate of deep infection in patients treated in Medical City, Baghdad, Iraq due to terrorist activity from 2004-2008. This is a retrospective review of a series of open limb fractures. A total of 102 civilian patients with 114 limb fractures due to high-velocity missile injuries were selected for this study from Medical City records. Patients were followed in the outpatient department in Medical City Teaching Complex both clinically and radiologically. Surgical treatment was accomplished in less than six hours from time of injury in group A (55 fractures, 48.4%) and more than six hours in group B (59 fractures, 51.7%). The infection rate for group A was 30.9% and group B was 23.7%. A very high infection rate was noted for these injuries, and there was no increase in the rate of deep infection in patients treated more than six hours after the injury.

  17. The use of 3D-printed titanium mesh tray in treating complex comminuted mandibular fractures

    PubMed Central

    Ma, Junli; Ma, Limin; Wang, Zhifa; Zhu, Xiongjie; Wang, Weijian

    2017-01-01

    Abstract Rationale: Precise bony reduction and reconstruction of optimal contour in treating comminuted mandibular fractures is very difficult using traditional techniques and devices. The aim of this report is to introduce our experiences in using virtual surgery and three-dimensional (3D) printing technique in treating this clinical challenge. Patient concerns: A 26-year-old man presented with severe trauma in the maxillofacial area due to fall from height. Diagnosis: Computed tomography images revealed middle face fractures and comminuted mandibular fracture including bilateral condyles. Interventions and outcomes: The computed tomography data was used to construct the 3D cranio-maxillofacial models; then the displaced bone fragments were virtually reduced. On the basis of the finalized model, a customized titanium mesh tray was designed and fabricated using selective laser melting technology. During the surgery, a submandibular approach was adopted to repair the mandibular fracture. The reduction and fixation were performed according to preoperative plan, the bone defects in the mental area were reconstructed with iliac bone graft. The 3D-printed mesh tray served as an intraoperative template and carrier of bone graft. The healing process was uneventful, and the patient was satisfied with the mandible contour. Lessons: Virtual surgical planning combined with 3D printing technology enables surgeon to visualize the reduction process preoperatively and guide intraoperative reduction, making the reduction less time consuming and more precise. 3D-printed titanium mesh tray can provide more satisfactory esthetic outcomes in treating complex comminuted mandibular fractures. PMID:28682875

  18. Complex Contact Angles Calculated from Capillary Rise Measurements on Rock Fracture Faces

    NASA Astrophysics Data System (ADS)

    Perfect, E.; Gates, C. H.; Brabazon, J. W.; Santodonato, L. J.; Dhiman, I.; Bilheux, H.; Bilheux, J. C.; Lokitz, B. S.

    2017-12-01

    Contact angles for fluids in unconventional reservoir rocks are needed for modeling hydraulic fracturing leakoff and subsequent oil and gas extraction. Contact angle measurements for wetting fluids on rocks are normally performed using polished flat surfaces. However, such prepared surfaces are not representative of natural rock fracture faces, which have been shown to be rough over multiple scales. We applied a variant of the Wilhelmy plate method for determining contact angle from the height of capillary rise on a vertical surface to the wetting of rock fracture faces by water in the presence of air. Cylindrical core samples (5.05 cm long x 2.54 cm diameter) of Mancos shale and 6 other rock types were investigated. Mode I fractures were created within the cores using the Brazilian method. Each fractured core was then separated into halves exposing the fracture faces. One fracture face from each rock type was oriented parallel to a collimated neutron beam in the CG-1D imaging instrument at ORNL's High Flux Isotope Reactor. Neutron radiography was performed using the multi-channel plate detector with a spatial resolution of 50 μm. Images were acquired every 60 s after a water reservoir contacted the base of the fracture face. The images were normalized to the initial dry condition so that the upward movement of water on the fracture face was clearly visible. The height of wetting at equilibrium was measured on the normalized images using ImageJ. Contact angles were also measured on polished flat surfaces using the conventional sessile drop method. Equilibrium capillary rise on the exposed fracture faces was up to 8.5 times greater than that predicted for polished flat surfaces from the sessile drop measurements. These results indicate that rock fracture faces are hyperhydrophilic (i.e., the height of capillary rise is greater than that predicted for a contact angle of zero degrees). The use of complex numbers permitted calculation of imaginary contact angles for such surfaces. This analysis yielded a continuum of contact angles (real above, and imaginary below, zero degrees) that can be used to investigate relationships with properties such surface roughness and porosity. It should be noted these are preliminary, unreplicated results and further research will be needed to verify them and refine the approach.

  19. Percutaneous Instrumentation of a Complex Lumbar Spine Fracture with Bilateral Pedicle Dissociation: Case Report and Technical Note.

    PubMed

    Luther, Evan; Urakov, Timur; Vanni, Steven

    2018-06-11

     Complex traumatic lumbar spine fractures are difficult to manage and typically occur in younger patients. Surgical immobilization for unstable fractures is an accepted treatment but can lead to future adjacent-level disease. Furthermore, large variations in fracture morphology create significant difficulties when attempting fixation. Therefore, a surgical approach that considers both long-term outcomes and fracture type is of utmost importance. We present a novel technique for percutaneous fixation without interbody or posterolateral fusion in a young patient with bilateral pedicle dissociations and an acute-onset incomplete neurologic deficit.  A 20-year-old man involved in a motorcycle accident presented with unilateral right lower extremity paresis and sensory loss with intact rectal tone and no saddle anesthesia. Lumbar computed tomography (CT) demonstrated L2 and L3 fractures associated with bilateral pedicle dislocations. Lumbar magnetic resonance imaging showed draping of the conus medullaris/cauda equina anteriorly over the kyphotic deformity at L2 with minimal associated canal stenosis at L2 and L3. He was treated with emergent percutaneous fixation of the fracture segment without interbody or posterolateral fusion. Decompression was not performed because of the negligible amount of canal stenosis and high likelihood of cerebrospinal fluid leakage due to dural tears from the fractures. Surgical fixation of the L2 vertebra was achieved by cannulating the left pedicle with an oversized tap while holding the right pedicle in place with a normal tap and then driving screws into the left and right pedicles, respectively, thus reducing the free-floating fracture segment. At 18 months after surgery, a follow-up CT demonstrated good cortication across the prior pedicle fractures, and the instrumentation was removed without any obvious signs of instability or disruption of the alignment at the thoracolumbar junction.  We present a novel technique for percutaneous reduction and fixation of bilateral pedicle fractures with significant dissociation from the vertebral body, associated neural compression from the kyphotic deformity, and minimal spinal canal stenosis. Furthermore, we argue that early fixation and reduction of the fracture prevented irreversible neurologic compromise, and the absence of interbody or posterolateral fusion ultimately preserved the spinal mobility of the patient once the hardware was removed. Georg Thieme Verlag KG Stuttgart · New York.

  20. Lidar-based fracture characterization: An outcrop-scale study of the Woodford Shale, McAlister Shale Pit, Oklahoma

    NASA Astrophysics Data System (ADS)

    Hanzel, Jason

    The use of lidar (light detection and ranging), a remote sensing tool based on principles of laser optometry, in mapping complex, multi-scale fracture networks had not been rigorously tested prior to this study despite its foreseeable utility in interpreting rock fabric with imprints of complex tectonic evolution. This thesis demonstrates lidar-based characterization of the Woodford Shale where intense fracturing could be due to both tectonism and mineralogy. The study area is the McAlister Shale Pit in south-central Oklahoma where both the upper and middle sections of the Woodford Shale are exposed and can be lidar-mapped. Lidar results are validated using hand-measured strike and dips of fracture planes, thin sections and mineral chemistry of selected samples using X-ray diffraction (XRD). Complexity of the fracture patterns as well as inaccessibility of multiple locations within the shale pit makes hand-measurement prone to errors and biases; lidar provides an opportunity for less biased and more efficient field mapping. Fracture mapping with lidar is a multi-step process. The lidar data are converted from point clouds into a mesh through triangulation. User-defined parameters such as size and orientation of the individual triangular elements are then used to group similar elements into surfaces. The strike and dip attribute of the simulated surfaces are visualized in an equal area lower hemisphere projection stereonet. Three fracture sets were identified in the upper and middle sections with common orientation but substantially different spatial density. Measured surface attributes and spatial density relations from lidar were validated using their hand-measured counterparts. Thin section analysis suggests that high fracture density in the upper Woodford measured by both the lidar and the hand-measured data could be due to high quartz. A significant finding of this study is the reciprocal relation between lidar intensity and gamma-ray (GR), which is generally used to infer outcrop mineralogy. XRD analysis of representative samples along the common profiles show that both GR and lidar intensity were influenced by the same minerals in essentially opposite ways. Results strongly suggest that the lidar cannot only remotely map the geomorphology, but also the relative mineralogical variations to the first order of approximation.

  1. Fully Coupled 3D Finite Element Model of Hydraulic Fracturing in a Permeable Rock Formation

    NASA Astrophysics Data System (ADS)

    Salimzadeh, S.; Paluszny, A.; Zimmerman, R. W.

    2015-12-01

    Hydraulic fracturing in permeable rock formations is a complex three-dimensional multi-physics phenomenon. Numerous analytical models of hydraulic fracturing processes have been proposed that typically simplify the physical processes, or somehow reduce the problem from three dimensions to two dimensions. Moreover, although such simplified models are able to model the growth of a single hydraulic fracture into an initially intact, homogeneous rock mass, they are generally not able to model fracturing of heterogeneous rock formations, or to account for interactions between multiple induced fractures, or between an induced fracture and pre-existing natural fractures. We have developed a numerical finite-element model for hydraulic fracturing that does not suffer from any of the limitations mentioned above. The model accounts for fluid flow within a fracture, the propagation of the fracture, and the leak-off of fluid from the fracture into the host rock. Fluid flow through the permeable rock matrix is modelled using Darcy's law, and is coupled with the laminar flow within the fracture. Fractures are discretely modelled in the three-dimensional mesh. Growth of a fracture is modelled using the concepts of linear elastic fracture mechanics (LEFM), with the onset and direction of growth based on stress intensity factors that are computed for arbitrary tetrahedral meshes. The model has been verified against several analytical solutions available in the literature for plane-strain (2D) and penny-shaped (3D) fractures, for various regimes of domination: viscosity, toughness, storage and leak-off. The interaction of the hydraulically driven fracture with pre-existing fractures and other fluid-driven fractures in terms of fluid leak-off, stress interaction and fracture arrest is investigated and the results are presented. Finally, some preliminary results are presented regarding the interaction of a hydraulically-induced fracture with a set of pre-existing natural fractures.

  2. [Locked volar plating for complex distal radius fractures: maintaining radial length].

    PubMed

    Jeudy, J; Pernin, J; Cronier, P; Talha, A; Massin, P

    2007-09-01

    Maintaining radial length, likely to be the main challenge in the treatment of complex distal radius fractures, is necessary for complete grip-strength and pro-supination range recovery. In spite of frequent secondary displacements, bridging external-fixation has remained the reference method, either isolated or in association with additional percutaneous pins or volar plating. Also, there seems to be a relation between algodystrophy and the duration of traction applied on the radio-carpal joint. Fixed-angle volar plating offers the advantage of maintaining the reduction until fracture healing, without bridging the joint. In a prospective study, forty-three consecutive fractures of the distal radius with a positivated ulnar variance were treated with open reduction and fixed-angle volar plating. Results were assessed with special attention to the radial length and angulation obtained and maintained throughout treatment, based on repeated measurements of the ulnar variance and radial angulation in the first six months postoperatively. The correction of the ulnar variance was maintained until complete recovery, independently of initial metaphyseal comminution, and of the amount of radial length gained at reduction. Only 3 patients lost more than 1 mm of radial length after reduction. The posterior tilt of the distal radial epiphysis was incompletely reduced in 13 cases, whereas reduction was partially lost in 6 elderly osteoporotic female patients. There was 8 articular malunions, all of them less than 2 mm. Secondary displacements were found to be related to a deficient locking technique. Eight patients developed an algodystropy. The risk factors for algodystrophy were articular malunion, associated posterior pining, and associated lesions of the ipsilateral upper limb. Provided that the locking technique was correct, this type of fixation appeared efficient in maintaining the radial length in complex fractures of the distal radius. The main challenge remains the reduction of displaced articular fractures. Based on these results, it is not possible to conclude that this method is superior to external fixation.

  3. Numerical Investigation of Fracture Propagation in Geomaterials

    NASA Astrophysics Data System (ADS)

    Newell, P.; Borowski, E.; Major, J. R.; Eichhubl, P.

    2015-12-01

    Fracture in geomaterials is a critical behavior that affects the long-term structural response of geosystems. The processes involving fracture initiation and growth in rocks often span broad time scales and size scales, contributing to the complexity of these problems. To better understand fracture behavior, the authors propose an initial investigation comparing the fracture testing techniques of notched three-point bending (N3PB), short rod (SR), and double torsion (DT) on geomaterials using computational analysis. Linear softening cohesive fracture modeling (LCFM) was applied using ABAQUS to computationally simulate the three experimental set-ups. By applying material properties obtained experimentally, these simulations are intended to predict single-trace fracture growth. The advantages and limitations of the three testing techniques were considered for application to subcritical fracture propagation taking into account the accuracy of constraints, load applications, and modes of fracture. This work is supported as part of the Geomechanics of CO2 Reservoir Seals, a DOE-NETL funded under Award Number DE-FOA-0001037. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  4. Detection of Fracture Patterns Within the Southern Portion of a Residential Complex (Tepozanes), Los Reyes-La Paz County (Edo. de Mexico)

    NASA Astrophysics Data System (ADS)

    Chavez, R. E.; Arango, C.; Tejero, A.; Cifuentes, G.; Hernandez, E.

    2008-12-01

    Most of the urban zone within the Valley of Mexico is built on top of the sediments of the ancient lakes of Chalco, Xochimilco, Mexico, Texcoco, Xaltocan and Zumpango. The sediments that cover this great valley are mainly composed by highly saturated clay-sandy materials; which offer a weak resistance to the constructions built on top. In addition, the increasing need of water supply for the population living in the valley (~22 million inhabitants) has weakened the main groundwater aquifers. This has lead to a differentiated subsidence and collapse of buildings, habitation units and roads. These effects put in a serious risk the inhabitants and the infrastructure of the city. As an example, we present a case of an area located in a densely populated zone, within a low-income residential complex denominated Tepozanes. This is located in the Los Reyes-La Paz County (Mexico State), towards the southeastern portion of the Valley of Mexico. The area is geologically limited by the Chimalhuacan Hill to the N, by the Santa Catarina volcanic range to the S. The previously mentioned effects are evident in the constructions of some buildings, where an exposed fracture is found in the NE-SW direction. This feature is affecting the structure of one of them in the residential complex, where the fracture runs underneath. A geophysical study was proposed to characterize the subsoil and to define the fracturing patterns in the zone. The electrical resistivity tomography (ETR) method employing the capacitive and galvanic modes was used to define the fracturing patters and the position at depth of the saturated layers, which might affect the Residential buildings. As a complement, GPR (Ground Penetrating Radar) profiles were carried out on the same profiles to correlate the information obtained from the ETR capacitive method which has a better resolution in the shallower zone. The computed results show that the buildings foundations were set on top of a high resistivity layer (~1000 Ohm-m), with variable thickness (5 m to 20 m). This layer depicts important discontinuities that can be associated to fractures. Low resistivity sediments lie on top of the resistive horizon. This feature corresponds to saturated sediments (clays and sands) that due to the water flow tend to form areas with low mechanical resistance and vey high compressibility, producing subsidence, following the fracture pattern in the resistive layer. The GPR study defined the presence of small fractures to depths ranging between 1 m and 3 m, which can be correlated with the information provided by the capacitive method. A subsidence map was produced for the studied zone. The fracture pattern is found in the SW-NE direction, affecting the residential complex at the surrounding. Three exploratory wells were drilled within the studied area. The stratigraphy obtained correlated well with the electrical models.

  5. Fatigue crack propagation path across the dentinoenamel junction complex in human teeth.

    PubMed

    Dong, X D; Ruse, N D

    2003-07-01

    The human tooth structures should be understood clearly to improve clinically used restorative materials. The dentinoenamel junction (DEJ) plays a key role in resisting crack propagation in teeth. The aim of this study was to determine the fracture toughness of the enamel-DEJ-dentin complex and to investigate the influence of the DEJ on the fatigue crack propagation path across it by characterizing fatigue-fractured enamel-DEJ-dentin complexes using optical and scanning electron microscopy. The results of this study showed that the fracture toughness of the enamel-DEJ-dentin complex was 1.50 +/- 0.28 Mpa x m(1/2). Based on the results of this investigation, it was concluded that the DEJ complex played a critical role in resisting crack propagation from enamel into dentin. The DEJ complex is, approximately, a 100 to 150 microm broad region at the interface between enamel and dentin. The toughening mechanism of the DEJ complex may be explained by the fact that crack paths were deflected as cracks propagated across it. Understanding the mechanism of crack deflection could help in improving dentin-composite as well as ceramic-cement interfacial qualities with the aim to decrease the risk of clinical failure of restorations. Both can be viewed as being composed from a layer of material of high strength and hardness bonded to a softer but tougher substratum (dentin). The bonding agent or the luting cement layer may play the critical role of the DEJ in improving the strength of these restorations in clinical situations. Copyright 2003 Wiley Periodicals, Inc.

  6. In Situ Fracture of Stents Implanted for Relief of Pulmonary Arterial Stenosis in Patients with Congenitally Malformed Hearts

    PubMed Central

    McElhinney, Doff B.; Bergersen, Lisa; Marshall, Audrey C.

    2014-01-01

    Background One of the most common uses of stents in patients with congenitally malformed hearts is treatment of pulmonary arterial stenosis. Although there are reports of fractured pulmonary arterial stents, little is known about the risk factors for, and implications of, such fractures. Methods We reviewed angiograms to identify fractures in stents previously inserted to relieve stenoses in pulmonary arteries from 1990 through 2001 in patients who also underwent follow-up catheterization at least 3 years after placement of the stent. We undertook matched cohort analysis, matching a ratio of 2 fractured to 1 unfractured stent. Results Overall, 166 stents meeting the criterions of our study had been placed in 120 patients. We identified fractures in 35 stents (21%) in 29 patients. All fractured stents were in the central pulmonary arteries, 24 (69%) in the central part of the right pulmonary artery, and all were complete axial fractures, or complex fractures along at least 2 planes. Stent-related factors associated with increased risk of fracture identified by multivariable logistic regression included placement in close apposition to the ascending aorta (p = 0.001), and a larger expanded diameter (p = 0.002). There was obstruction across 28 of 35 fractured stents, which was severe in 11. We re-stented 21 of the fractured stents, and recurrent fracture was later diagnosed in 3 of these. A fragment of the fractured stent embolized distally in 2 patients, without clinically important effects. Conclusions In situ fracture of pulmonary arterial stents is relatively common, and in most cases is related to compression by the aorta. There is usually recurrent obstruction across the fractured stent, but fractured stents rarely embolize, and are not associated with other significant complications. PMID:18559137

  7. Simulation of a multistage fractured horizontal well in a water-bearing tight fractured gas reservoir under non-Darcy flow

    NASA Astrophysics Data System (ADS)

    Zhang, Rui-Han; Zhang, Lie-Hui; Wang, Rui-He; Zhao, Yu-Long; Huang, Rui

    2018-06-01

    Reservoir development for unconventional resources such as tight gas reservoirs is in increasing demand due to the rapid decline of production in conventional reserves. Compared with conventional reservoirs, fluid flow in water-bearing tight gas reservoirs is subject to more nonlinear multiphase flow and gas slippage in nano/micro matrix pores because of the strong collisions between rock and gas molecules. Economic gas production from tight gas reservoirs depends on extensive application of water-based hydraulic fracturing of horizontal wells, associated with non-Darcy flow at a high flow rate, geomechanical stress sensitivity of un-propped natural fractures, complex flow geometry and multiscale heterogeneity. How to efficiently and accurately predict the production performance of a multistage fractured horizontal well (MFHW) is challenging. In this paper, a novel multicontinuum, multimechanism, two-phase simulator is established based on unstructured meshes and the control volume finite element method to analyze the production performance of MFHWs. The multiple interacting continua model and discrete fracture model are coupled to integrate the unstimulated fractured reservoir, induced fracture networks (stimulated reservoir volumes, SRVs) and irregular discrete hydraulic fractures. Several simulations and sensitivity analyses are performed with the developed simulator for determining the key factors affecting the production performance of MFHWs. Two widely applied fracturing models, classic hydraulic fracturing which generates long double-wing fractures and the volumetric fracturing aimed at creating large SRVs, are compared to identify which of them can make better use of tight gas reserves.

  8. Managment of frontal sinus fracture: obliteration sinus with cancellous bone graft.

    PubMed

    Muminagic, Sahib; Masic, Tarik; Babajic, Emina; Asotic, Mithat

    2011-01-01

    Frontal sinus fractures make up about 2-15% of all facial fractures.This is relatively low frequency of occurrence, but it has a large potential of complication and may involve not only the frontal sinuse but more importantly the brain and the eyes. The management depends of the complexity. If anterior wall is fractured with grossly involved nasofrontal duct (NFD) in the injury it is paramount to occlude NFD. Very often, sinus obliteration is done at the same time. In our expirience autogenous cancellous bone graft is considered to be the best grafting material. It has the less short - or long-term complications and the donor site morbidity is insignificant.

  9. Biomechanical investigation of naso-orbitoethmoid trauma by finite element analysis.

    PubMed

    Huempfner-Hierl, Heike; Schaller, Andreas; Hemprich, Alexander; Hierl, Thomas

    2014-11-01

    Naso-orbitoethmoid fractures account for 5% of all facial fractures. We used data derived from a white 34-year-old man to make a transient dynamic finite element model, which consisted of about 740 000 elements, to simulate fist-like impacts to this anatomically complex area. Finite element analysis showed a pattern of von Mises stresses beyond the yield criterion of bone that corresponded with fractures commonly seen clinically. Finite element models can be used to simulate injuries to the human skull, and provide information about the pathogenesis of different types of fracture. Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Horizontal root fracture treated with MTA, a case report with a 10-year follow-up.

    PubMed

    Roig, Miguel; Espona, José; Mercadé, Montse; Duran-Sindreu, Fernando

    2011-12-01

    Root fractures occur more frequently in fully erupted permanent teeth with closed apices in which the completely formed root is solidly supported in the bone and periodontium. The consequences can be complex because of combined damage to the pulp, dentine, cementum, bone, and periodontium. Management of horizontal root fractures and lateral luxation depends on several factors, with the result that various clinical modalities have been suggested. This case report describes the treatment and 10-year follow-up of two maxillary central incisors, one with horizontal root fracture and the other with lateral luxation, treated with mineral trioxide aggregate and root canal treatment, respectively. © 2011 John Wiley & Sons A/S.

  11. Karst in Wadi Bani Khalid, Oman

    NASA Astrophysics Data System (ADS)

    Abdelaziz, Ramadan

    2017-04-01

    There are several important in Oman. The main aquifer is surficial aquifer and fractured rocks. In fact, the geology of Oman is complex whichmake the hydraulic continuity of bedrock is limited and formaing localized aquifers. caves in Oman are varying types and length, size and geographic formations. Many caves and valleys founded in Oman. Wadi Bani Khalid hosts complex network of fractured rock. Karst in Wadi Bani Kalid made upof Limestone(Calcium, which is dissolve in water.A rain water pass through the rock it is erode the rock and form caves. The cave located in Miqil. The karst was formed in Calcium Carbonate rocks.

  12. The importance of physical function to people with osteoporosis.

    PubMed

    Kerr, C; Bottomley, C; Shingler, S; Giangregorio, L; de Freitas, H M; Patel, C; Randall, S; Gold, D T

    2017-05-01

    There is increasing need to understand patient outcomes in osteoporosis. This article discusses that fracture in osteoporosis can lead to a cycle of impairment, driven by complex psychosocial factors, having a profound impact on physical function/activity which accumulates over time. More information is required on how treatments impact physical function. There is increasing need to understand patient-centred outcomes in osteoporosis (OP) clinical research and management. This multi-method paper provides insight on the effect of OP on patients' physical function and everyday activity. Data were collected from three sources: (1) targeted literature review on OP and physical function, conducted in MEDLINE, Embase and PsycINFO; (2) secondary thematic analysis of transcripts from patient interviews, conducted to develop a patient-reported outcome instrument. Transcripts were re-coded to focus on OP impact on daily activities and physical function for those with and without fracture history; and (3) discussions of the literature review and secondary qualitative analysis results with three clinical experts to review and interpret the importance and implications of the findings. Results suggest that OP, particularly with fracture, can have profound impacts on physical function/activity. These impacts accumulate over time through a cycle of impairment, as fracture leads to longer term detriments in physical function, including loss of muscle, activity avoidance and reduced physical capacity, which in turn leads to greater risk of fracture and potential for further physical restrictions. The cycle of impairment is complex, as other physical, psychosocial and treatment-related factors, such as comorbidities, fears and beliefs about physical activity and fracture risk influence physical function and everyday activity. More information on how treatments impact physical function would benefit healthcare professionals and persons with OP in making treatment decisions and improving treatment compliance/persistence, as these impacts may be more salient to patients than fracture incidence.

  13. A simulation trainer for complex articular fracture surgery.

    PubMed

    Yehyawi, Tameem M; Thomas, Thaddeus P; Ohrt, Gary T; Marsh, J Lawrence; Karam, Matthew D; Brown, Thomas D; Anderson, Donald D

    2013-07-03

    The purposes of this study were (1) to develop a physical model to improve articular fracture reduction skills, (2) to develop objective assessment methods to evaluate these skills, and (3) to assess the construct validity of the simulation. A surgical simulation was staged utilizing surrogate tibial plafond fractures. Multiple three-segment radio-opacified polyurethane foam fracture models were produced from the same mold, ensuring uniform surgical complexity between trials. Using fluoroscopic guidance, five senior and seven junior orthopaedic residents reduced the fracture through a limited anterior window. The residents were assessed on the basis of time to completion, hand movements (tracked with use of a motion capture system), and quality of the obtained reduction. All but three of the residents successfully reduced and fixed the fracture fragments (one senior resident and two junior residents completed the reduction but were unsuccessful in fixating all fragments). Senior residents had an average time to completion of 13.43 minutes, an average gross articular step-off of 3.00 mm, discrete hand motions of 540 actions, and a cumulative hand motion distance of 79 m. Junior residents had an average time to completion of 14.75 minutes, an average gross articular step-off of 3.09 mm, discrete hand motions of 511 actions, and a cumulative hand motion distance of 390 m. The large difference in cumulative hand motion distance, despite comparable numbers of discrete hand motion events, indicates that senior residents were more precise in their hand motions. The present experiment establishes the basic construct validity of the simulation trainer. Further studies are required to demonstrate that this laboratory-based model for articular fracture reduction training, along with an objective assessment of performance, can be used to improve resident surgical skills.

  14. Functional and radiological evaluations of high-energy tibial plateau fractures treated with double-buttress plate fixation.

    PubMed

    Yu, Z; Zheng, L; Zhang, Y; Li, J; Ma, Bao'an

    2009-05-14

    This study was designed to evaluate the functional and radiological outcomes of patients with complex tibial plateau fractures treated with double-buttress plate fixation. Sixty five cases of complex (Schatzker type V and VI) tibial plateau fractures were treated with double-buttress plate fixation in our centre from September 2001 to September 2006 through two separate plate incisions. Fifty four patients were followed up for a period ranging from 12 to 48 months and evaluated for the functional and radiological outcomes by a series of standard questionnaire and measurement. Due to the good exposure without any extensive soft-tissue dissection of the double-buttress plate fixation, the fractures in all 54 patients were healed and the treatment achieved greater than 90% of satisfactory-to-excellent rates of reduction. The mean time of bone union was 15.4 weeks (range, 12-30 weeks), and the mean time of full weight-bearing was 18.7 weeks (range, 14-26 weeks). At the final follow-up visit, no patients showed knee instability; the mean range of motion was 107.6 degrees (range, 85 degrees -130 degrees ). For all patients, no statistically significant difference in the functional outcomes was observed between their 6-months and final follow-up visits; or in the radiological findings between their immediate postoperative and final follow-up examinations. Double-buttress plate fixation is a feasible treatment option for bilcondylar and complex tibial plateau fractures. Although technically demanding, it offers reliable stability without additional postoperative adjuvant external fixation, and at the same time avoids extensive soft tissue dissection, allowing the early painless range of motion.

  15. Complex pelvic ring injuries associated with floating knee in a poly-trauma patient: A case report.

    PubMed

    Zhou, Yuebin; Guo, Honggang; Cai, Zhiwei; Zhang, Yuan

    2017-12-01

    Complex pelvic ring fracture associated with floating knee is comparatively rare which usually results from high-energy trauma including vehicle-related accidence, falls from height, and earthquake-related injury. To our knowledge, few literatures have documented such injuries in the individual patient. Management of both injuries present challenges for surgical management and postoperative care. The purpose of this study is to prove the feasibility and benefits of damage control orthopedics (DCO). Our case involved a 45-year-old lady who was hit by a dilapidated building. The patient was anxious, pale and hemodynamically stable at the initial examination. The pelvis was unstable and there were obvious deformities in the left lower extremities. Significant degloved injuries in the left leg were noted. Her radiographs and physical examination verified the above signs. Unstable pelvic fractures, multiple fractures of bilateral lower limbs with floating knee injury, multiple pelvic and rib fractures and multiple degloving injuries and soft tissue contusion formed the characteristics of the multiple-injury. The algorithm of DCO was determined as the treatment. Early simplified procedures such as wound debridement, pelvis fixation, closed reduction and EF of the right shoulder joint, and chest wall fixation were conducted as soon as possible. After a period of time, internal fixations were applied to the fracture sites. The subsequent functional exercise was also conducted in accordance with this algorithm. This patient got recovery after the treatments which were guided by the criterion of DCO. The restoration of limb functional and the quality of life greatly improved. The DCO plays a decisive role in the first aid and follow-up treatment of this patient. The guidelines of management of complex pelvic ring injuries and floating knee should be established by authorities.

  16. Description and hydrogeologic implications of cored sedimentary material from the 1975 drilling program at the radioactive waste management complex, Idaho

    USGS Publications Warehouse

    Rightmire, C.T.

    1984-01-01

    Samples of sedimentary material from interbeds between basalt flows and from fractures in the flows, taken from two drill cores at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory were analyzed for (1) particle-size dribution, (2) bulk mineralogy, (3) clay mineralogy, (4) cation-exchange capacity, and (5) carbonate content. Thin sections of selected sediment material were made for petrographic examination. Preliminary interpretations indicate that (1) it may be possible to distinguish the various sediment interbeds on the basis of their mineralogy, (2) the presence of carbonate horizons in sedimentary interbeds may be utilized to approximate the time of exposure and the climate while the surface was exposed (which affected the hydrogeologic character of the sediment), and the type and orientation of fracture-filling material may be utilized to determine the mechanism by which fractures were filled. (USGS)

  17. Analysis of macroscopic fractures in granite in the HDR geothermal well EPS-1, Soultz-sous-Foreêts, France

    NASA Astrophysics Data System (ADS)

    Genter, Albert; Traineau, Hervé

    1996-07-01

    An exhaustive analysis of 3000 macroscopic fractures encountered in the geothermal Hot Dry Rock borehole, EPS-1, located inside the Rhine graben (Soultz-sous-Foreˆts, France), was done on a continuous core section over a depth interval from 1420 to 2230 m: 97% of the macroscopic structures were successfully reorientated with a good degree of confidence by comparison between core and acoustic borehole imagery. Detailed structural analysis of the fracture population indicates that fractures are grouped in two principal fractures sets striking N005 and N170 °, and dipping 70 °W and 70 °E, respectively. This average attitude is closely related to the past tectonic rifting activity of the graben during the Tertiary, and is consistent with data obtained from nearby boreholes and from neighbouring crystalline outcrops. Fractures are distributed in clusters of hydrothermally altered and fractured zones. They constitute a complex network of fault strands dominated by N-S trends, except within some of the most fractured depth intervals (1650 m, 2170 m), where an E-W-striking fracture set occurs. The geometry of the pre-existing fracture system strikes in a direction nearly parallel to the maximum horizontal stress. In this favorable situation, hydraulic injections will tend both to reactivate natural fractures at low pressures, and to create a geothermal reservoir.

  18. [Surgical approaches to tibial plateau fractures].

    PubMed

    Krause, Matthias; Müller, Gunnar; Frosch, Karl-Heinz

    2018-06-06

    Intra-articular tibial plateau fractures can present a surgical challenge due to complex injury patterns and compromised soft tissue. The treatment goal is to spare the soft tissue and an anatomical reconstruction of the tibial articular surface. Depending on the course of the fracture, a fracture-specific access strategy is recommended to provide correct positioning of the plate osteosynthesis. While the anterolateral approach is used in the majority of lateral tibial plateau fractures, only one third of the joint surface is visible; however, posterolateral fragments require an individual approach, e. g. posterolateral or posteromedial. If necessary, osteotomy of the femoral epicondyles can improve joint access for reduction control. Injuries to the posterior columns should be anatomically reconstructed and biomechanically correctly addressed via posterior approaches. Bony posterior cruciate ligament tears can be refixed via a minimally invasive posteromedial approach.

  19. Multiscale fracture network characterization and impact on flow: A case study on the Latemar carbonate platform

    NASA Astrophysics Data System (ADS)

    Hardebol, N. J.; Maier, C.; Nick, H.; Geiger, S.; Bertotti, G.; Boro, H.

    2015-12-01

    A fracture network arrangement is quantified across an isolated carbonate platform from outcrop and aerial imagery to address its impact on fluid flow. The network is described in terms of fracture density, orientation, and length distribution parameters. Of particular interest is the role of fracture cross connections and abutments on the effective permeability. Hence, the flow simulations explicitly account for network topology by adopting Discrete-Fracture-and-Matrix description. The interior of the Latemar carbonate platform (Dolomites, Italy) is taken as outcrop analogue for subsurface reservoirs of isolated carbonate build-ups that exhibit a fracture-dominated permeability. New is our dual strategy to describe the fracture network both as deterministic- and stochastic-based inputs for flow simulations. The fracture geometries are captured explicitly and form a multiscale data set by integration of interpretations from outcrops, airborne imagery, and lidar. The deterministic network descriptions form the basis for descriptive rules that are diagnostic of the complex natural fracture arrangement. The fracture networks exhibit a variable degree of multitier hierarchies with smaller-sized fractures abutting against larger fractures under both right and oblique angles. The influence of network topology on connectivity is quantified using Discrete-Fracture-Single phase fluid flow simulations. The simulation results show that the effective permeability for the fracture and matrix ensemble can be 50 to 400 times higher than the matrix permeability of 1.0 · 10-14 m2. The permeability enhancement is strongly controlled by the connectivity of the fracture network. Therefore, the degree of intersecting and abutting fractures should be captured from outcrops with accuracy to be of value as analogue.

  20. The Influence of Fracturing Fluids on Fracturing Processes: A Comparison Between Water, Oil and SC-CO2

    NASA Astrophysics Data System (ADS)

    Wang, Jiehao; Elsworth, Derek; Wu, Yu; Liu, Jishan; Zhu, Wancheng; Liu, Yu

    2018-01-01

    Conventional water-based fracturing treatments may not work well for many shale gas reservoirs. This is due to the fact that shale gas formations are much more sensitive to water because of the significant capillary effects and the potentially high contents of swelling clay, each of which may result in the impairment of productivity. As an alternative to water-based fluids, gaseous stimulants not only avoid this potential impairment in productivity, but also conserve water as a resource and may sequester greenhouse gases underground. However, experimental observations have shown that different fracturing fluids yield variations in the induced fracture. During the hydraulic fracturing process, fracturing fluids will penetrate into the borehole wall, and the evolution of the fracture(s) then results from the coupled phenomena of fluid flow, solid deformation and damage. To represent this, coupled models of rock damage mechanics and fluid flow for both slightly compressible fluids and CO2 are presented. We investigate the fracturing processes driven by pressurization of three kinds of fluids: water, viscous oil and supercritical CO2. Simulation results indicate that SC-CO2-based fracturing indeed has a lower breakdown pressure, as observed in experiments, and may develop fractures with greater complexity than those developed with water-based and oil-based fracturing. We explore the relation between the breakdown pressure to both the dynamic viscosity and the interfacial tension of the fracturing fluids. Modeling demonstrates an increase in the breakdown pressure with an increase both in the dynamic viscosity and in the interfacial tension, consistent with experimental observations.

  1. Fractures of the cervical spine

    PubMed Central

    Marcon, Raphael Martus; Cristante, Alexandre Fogaça; Teixeira, William Jacobsen; Narasaki, Douglas Kenji; Oliveira, Reginaldo Perilo; de Barros Filho, Tarcísio Eloy Pessoa

    2013-01-01

    OBJECTIVES: The aim of this study was to review the literature on cervical spine fractures. METHODS: The literature on the diagnosis, classification, and treatment of lower and upper cervical fractures and dislocations was reviewed. RESULTS: Fractures of the cervical spine may be present in polytraumatized patients and should be suspected in patients complaining of neck pain. These fractures are more common in men approximately 30 years of age and are most often caused by automobile accidents. The cervical spine is divided into the upper cervical spine (occiput-C2) and the lower cervical spine (C3-C7), according to anatomical differences. Fractures in the upper cervical spine include fractures of the occipital condyle and the atlas, atlanto-axial dislocations, fractures of the odontoid process, and hangman's fractures in the C2 segment. These fractures are characterized based on specific classifications. In the lower cervical spine, fractures follow the same pattern as in other segments of the spine; currently, the most widely used classification is the SLIC (Subaxial Injury Classification), which predicts the prognosis of an injury based on morphology, the integrity of the disc-ligamentous complex, and the patient's neurological status. It is important to correctly classify the fracture to ensure appropriate treatment. Nerve or spinal cord injuries, pseudarthrosis or malunion, and postoperative infection are the main complications of cervical spine fractures. CONCLUSIONS: Fractures of the cervical spine are potentially serious and devastating if not properly treated. Achieving the correct diagnosis and classification of a lesion is the first step toward identifying the most appropriate treatment, which can be either surgical or conservative. PMID:24270959

  2. The Influence of Hydraulic Fracturing on Carbon Storage Performance

    NASA Astrophysics Data System (ADS)

    Fu, Pengcheng; Settgast, Randolph R.; Hao, Yue; Morris, Joseph P.; Ryerson, Frederick J.

    2017-12-01

    Conventional principles of the design and operation of geologic carbon storage (GCS) require injecting CO2 below the caprock fracturing pressure to ensure the integrity of the storage complex. In nonideal storage reservoirs with relatively low permeability, pressure buildup can lead to hydraulic fracturing of the reservoir and caprock. While the GCS community has generally viewed hydraulic fractures as a key risk to storage integrity, a carefully designed stimulation treatment under appropriate geologic conditions could provide improved injectivity while maintaining overall seal integrity. A vertically contained hydraulic fracture, either in the reservoir rock or extending a limited height into the caprock, provides an effective means to access reservoir volume far from the injection well. Employing a fully coupled numerical model of hydraulic fracturing, solid deformation, and matrix fluid flow, we study the enabling conditions, processes, and mechanisms of hydraulic fracturing during CO2 injection. A hydraulic fracture's pressure-limiting behavior dictates that the near-well fluid pressure is only slightly higher than the fracturing pressure of the rock and is insensitive to injection rate and mechanical properties of the formation. Although a fracture contained solely within the reservoir rock with no caprock penetration, would be an ideal scenario, poroelastic principles dictate that sustaining such a fracture could lead to continuously increasing pressure until the caprock fractures. We also investigate the propagation pattern and injection pressure responses of a hydraulic fracture propagating in a caprock subjected to heterogeneous in situ stress. The results have important implications for the use of hydraulic fracturing as a tool for managing storage performance.

  3. Peripheral Faulting of Eden Patera: Potential Evidence in Support of a New Volcanic Construct on Mars

    NASA Astrophysics Data System (ADS)

    Harlow, J.

    2016-12-01

    Arabia Terra's (AT) pock-marked topography in the expansive upland region of Mars Northern Hemisphere has been assumed to be the result of impact crater bombardment. However, examination of several craters by researchers revealed morphologies inconsistent with neighboring craters of similar size and age. These 'craters' share features with terrestrial super-eruption calderas, and are considered a new volcanic construct on Mars called `plains-style' caldera complexes. Eden Patera (EP), located on the northern boundary of AT is a reference type for these calderas. EP lacks well-preserved impact crater morphologies, including a decreasing depth to diameter ratio. Conversely, Eden shares geomorphological attributes with terrestrial caldera complexes such as Valles Caldera (New Mexico): arcuate caldera walls, concentric fracturing/faulting, flat-topped benches, irregular geometric circumferences, etc. This study focuses on peripheral fractures surrounding EP to provide further evidence of calderas within the AT region. Scaled balloon experiments mimicking terrestrial caldera analogs have showcased fracturing/faulting patterns and relationships of caldera systems. These experiments show: 1) radial fracturing (perpendicular to caldera rim) upon inflation, 2) concentric faulting (parallel to sub-parallel to caldera rim) during evacuation, and 3) intersecting radial and concentric peripheral faulting from resurgence. Utilizing Mars Reconnaissance Orbiter Context Camera (CTX) imagery, peripheral fracturing is analyzed using GIS to study variations in peripheral fracture geometries relative to the caldera rim. Visually, concentric fractures dominate within 20 km, radial fractures prevail between 20 and 50 km, followed by gradation into randomly oriented and highly angular intersections in the fretted terrain region. Rose diagrams of orientation relative to north expose uniformly oriented mean regional stresses, but do not illuminate localized caldera stresses. Further examination of orientation relative to caldera rim reveals expected orientations of ±30° on rose diagrams, taking into account the geometric nature of concentric faulting. These results establish a quantitative geometric system to differentiate localized from regional faulting surrounding Eden Patera.

  4. Parallel numerical modeling of hybrid-dimensional compositional non-isothermal Darcy flows in fractured porous media

    NASA Astrophysics Data System (ADS)

    Xing, F.; Masson, R.; Lopez, S.

    2017-09-01

    This paper introduces a new discrete fracture model accounting for non-isothermal compositional multiphase Darcy flows and complex networks of fractures with intersecting, immersed and non-immersed fractures. The so called hybrid-dimensional model using a 2D model in the fractures coupled with a 3D model in the matrix is first derived rigorously starting from the equi-dimensional matrix fracture model. Then, it is discretized using a fully implicit time integration combined with the Vertex Approximate Gradient (VAG) finite volume scheme which is adapted to polyhedral meshes and anisotropic heterogeneous media. The fully coupled systems are assembled and solved in parallel using the Single Program Multiple Data (SPMD) paradigm with one layer of ghost cells. This strategy allows for a local assembly of the discrete systems. An efficient preconditioner is implemented to solve the linear systems at each time step and each Newton type iteration of the simulation. The numerical efficiency of our approach is assessed on different meshes, fracture networks, and physical settings in terms of parallel scalability, nonlinear convergence and linear convergence.

  5. Shale Fracture Analysis using the Combined Finite-Discrete Element Method

    NASA Astrophysics Data System (ADS)

    Carey, J. W.; Lei, Z.; Rougier, E.; Knight, E. E.; Viswanathan, H.

    2014-12-01

    Hydraulic fracturing (hydrofrac) is a successful method used to extract oil and gas from highly carbonate rocks like shale. However, challenges exist for industry experts estimate that for a single $10 million dollar lateral wellbore fracking operation, only 10% of the hydrocarbons contained in the rock are extracted. To better understand how to improve hydrofrac recovery efficiencies and to lower its costs, LANL recently funded the Laboratory Directed Research and Development (LDRD) project: "Discovery Science of Hydraulic Fracturing: Innovative Working Fluids and Their Interactions with Rocks, Fractures, and Hydrocarbons". Under the support of this project, the LDRD modeling team is working with the experimental team to understand fracture initiation and propagation in shale rocks. LANL's hybrid hydro-mechanical (HM) tool, the Hybrid Optimization Software Suite (HOSS), is being used to simulate the complex fracture and fragment processes under a variety of different boundary conditions. HOSS is based on the combined finite-discrete element method (FDEM) and has been proven to be a superior computational tool for multi-fracturing problems. In this work, the comparison of HOSS simulation results to triaxial core flooding experiments will be presented.

  6. Electrical characteristics of rocks in fractured and caved reservoirs

    NASA Astrophysics Data System (ADS)

    Tang, Tianzhi; Lu, Tao; Zhang, Haining; Jiang, Liming; Liu, Tangyan; Meng, He; Wang, Feifei

    2017-12-01

    The conductive paths formed by fractures and cave in complex reservoirs differ from those formed by pores and throats in clastic rocks. In this paper, a new formation model based on fractured and caved reservoirs is established, and the electrical characteristics of rocks are analyzed with different pore structures using resistance law to understand their effects on rock resistivity. The ratio of fracture width to cave radius (C e value) and fracture dip are employed to depict pore structure in this model. Our research shows that the electrical characteristics of rocks in fractured and caved reservoirs are strongly affected by pore structure and porous fluid distribution. Although the rock electrical properties associated with simple pore structure agree well with Archie formulae, the relationships between F and φ or between I and S w , in more complicated pore structures, are nonlinear in double logarithmic coordinates. The parameters in Archie formulae are not constant and they depend on porosity and fluid saturation. Our calculations suggest that the inclined fracture may lead to resistivity anisotropy in the formation. The bigger dip the inclining fracture has, the more anisotropy the formation resistivity has. All of these studies own practical sense for the evaluation of oil saturation using resistivity logging data.

  7. Unified pipe network method for simulation of water flow in fractured porous rock

    NASA Astrophysics Data System (ADS)

    Ren, Feng; Ma, Guowei; Wang, Yang; Li, Tuo; Zhu, Hehua

    2017-04-01

    Rock masses are often conceptualized as dual-permeability media containing fractures or fracture networks with high permeability and porous matrix that is less permeable. In order to overcome the difficulties in simulating fluid flow in a highly discontinuous dual-permeability medium, an effective unified pipe network method is developed, which discretizes the dual-permeability rock mass into a virtual pipe network system. It includes fracture pipe networks and matrix pipe networks. They are constructed separately based on equivalent flow models in a representative area or volume by taking the advantage of the orthogonality of the mesh partition. Numerical examples of fluid flow in 2-D and 3-D domain including porous media and fractured porous media are presented to demonstrate the accuracy, robustness, and effectiveness of the proposed unified pipe network method. Results show that the developed method has good performance even with highly distorted mesh. Water recharge into the fractured rock mass with complex fracture network is studied. It has been found in this case that the effect of aperture change on the water recharge rate is more significant in the early stage compared to the fracture density change.

  8. Forecasting the burden of future postmenopausal hip fractures.

    PubMed

    Omsland, T K; Magnus, J H

    2014-10-01

    A growing elderly population is expected worldwide, and the rate of hip fractures is decisive for the future fracture burden. Significant declines in hip fracture rates in Norway, the USA, France, Germany, and the UK are required to counteract the impact of the ageing effects. This study aims to evaluate the consequences of the expected growth of the elderly population worldwide on the hip fracture burden using Norway as an example. Furthermore, we wanted to estimate the decline in hip fracture rates required to counteract the anticipated increase in the burden of hip fracture for Norway, the USA, France, Germany, and the UK. The burden of future postmenopausal hip fractures in Norway were estimated given (1) constant age-specific rates, (2) continued decline, and (3) different cohort scenarios. Based on population projection estimates and population age-specific hip fracture rates in women 65 years and older, we calculated the required declines in hip fracture rates needed to counteract the growing elderly populations in Norway, the USA, France, Germany, and the UK. The level of age-specific hip fracture rates had a huge impact on the future hip fracture burden in Norway. Even if the hip fracture rates decline at the same speed, a 22 % increase in the burden of hip fractures can be expected by 2040. An annual decline in hip fracture rates of 1.1-2.2 % until 2040 is required to counteract the effects of the growing elderly population on the future burden of hip fractures in Norway, the USA, France, Germany, and the UK. Hip fracture rates have a great impact on the burden of hip fractures. The rates will have to decline significantly to counteract the impact of a growing elderly population. A change in preventive strategies and further studies are warranted to identify the complex causes associated to hip fractures.

  9. Fractures of the manubrium sterni: treatment options and a possible classification of different types of fractures

    PubMed Central

    Krinner, Sebastian; Oppel, Pascal; Grupp, Sina; Schulz-Drost, Melanie; Hennig, Friedrich F.; Langenbach, Andreas

    2018-01-01

    Background Sternum fractures are mostly located on the sternal corpus, seldom on the manubrium. Fractures of the sternal manubrium are, however, more frequently associated with severe concomitant injuries of thoracic organs, and therefore deserve special attention. In addition, in its function as a capstone in between the anterior chest wall and the shoulder girdle, it is exposed to a multiplicity of forces. Therefore the questions arise what types of fractures are observed in today’s clinical practice, how to classify them and which treatment options are available. This study reports on different types of fractures which involve the manubrium sterni. Methods Between January 2012 and October 2014, data was collected from all severely injured patients (ISS ≥16), which received a CT scan of the thorax in our Level-I-Trauma Center and retrospectively analyzed concerning sternal fractures. Fracture type, collateral injuries, age, and information about the circumstances of the accident were noted. Results Of 890 evaluable patients, 154 (17.3%) had a fracture of the sternum and 23 (2.6%) of the manubrium. Fractures of the manubrium appeared in following types: A-type—transverse fracture (n=11) in 1st intercostal space by direct blunt trauma or flexion of the torso with sagittal instability; B-type—oblique fracture (n=9) by seat belt injury with rotatory instability; C-type—combined, more fragmentary fracture (n=3) by direct blunt trauma with simultaneous flexion of the torso and multi directional instability. Fractures only little dislocation were treated conservatively, and unstable fractures were surgically stabilized (n=10). Conclusions In summary, three main types of fractures could be found. A-type fractures were stabilized with a longitudinal plate osteosynthesis and B-type fractures with transverse positioned plates. To treat complex C-type fractures, plates with a T- or H-form could be a good solution. Level of evidence: Level III retrospective prognostic cohort study PMID:29707289

  10. A new approach to fracture modelling in reservoirs using deterministic, genetic and statistical models of fracture growth

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rawnsley, K.; Swaby, P.

    1996-08-01

    It is increasingly acknowledged that in order to understand and forecast the behavior of fracture influenced reservoirs we must attempt to reproduce the fracture system geometry and use this as a basis for fluid flow calculation. This article aims to present a recently developed fracture modelling prototype designed specifically for use in hydrocarbon reservoir environments. The prototype {open_quotes}FRAME{close_quotes} (FRActure Modelling Environment) aims to provide a tool which will allow the generation of realistic 3D fracture systems within a reservoir model, constrained to the known geology of the reservoir by both mechanical and statistical considerations, and which can be used asmore » a basis for fluid flow calculation. Two newly developed modelling techniques are used. The first is an interactive tool which allows complex fault surfaces and their associated deformations to be reproduced. The second is a {open_quotes}genetic{close_quotes} model which grows fracture patterns from seeds using conceptual models of fracture development. The user defines the mechanical input and can retrieve all the statistics of the growing fractures to allow comparison to assumed statistical distributions for the reservoir fractures. Input parameters include growth rate, fracture interaction characteristics, orientation maps and density maps. More traditional statistical stochastic fracture models are also incorporated. FRAME is designed to allow the geologist to input hard or soft data including seismically defined surfaces, well fractures, outcrop models, analogue or numerical mechanical models or geological {open_quotes}feeling{close_quotes}. The geologist is not restricted to {open_quotes}a priori{close_quotes} models of fracture patterns that may not correspond to the data.« less

  11. Surgical Management of Complex Lower-Extremity Trauma With a Long Hindfoot Fusion Nail: A Case Report.

    PubMed

    Jain, Nickul S; Lopez, Gregory D; Bederman, S Samuel; Wirth, Garrett A; Scolaro, John A

    2016-08-01

    High-energy injuries can result in complete or partial loss of the talus. Ipsilateral fractures to the lower limb increase the complexity of surgical management, and treatment is guided by previous case reports of similar injuries. A case of complex lower-extremity trauma with extruded and missing talar body and ipsilateral type IIIB open tibia fracture is presented. Surgical limb reconstruction and salvage was performed successfully with a single orthopaedic implant in a manner not described previously in the literature. The purpose of this case report is to present the novel use of a single orthopaedic implant for treatment of a complex, open traumatic injury. Previous case reports in the literature have described the management of complete or partial talar loss. We describe the novel use of a long hindfoot fusion nail and staged bone grafting to achieve tibiocalcaneal arthrodesis for the treatment of complex lower-extremity trauma. Therapeutic, Level IV: Case study. © 2015 The Author(s).

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Zhou; H. Huang; M. Deo

    Log and seismic data indicate that most shale formations have strong heterogeneity. Conventional analytical and semi-analytical fracture models are not enough to simulate the complex fracture propagation in these highly heterogeneous formation. Without considering the intrinsic heterogeneity, predicted morphology of hydraulic fracture may be biased and misleading in optimizing the completion strategy. In this paper, a fully coupling fluid flow and geomechanics hydraulic fracture simulator based on dual-lattice Discrete Element Method (DEM) is used to predict the hydraulic fracture propagation in heterogeneous reservoir. The heterogeneity of rock is simulated by assigning different material force constant and critical strain to differentmore » particles and is adjusted by conditioning to the measured data and observed geological features. Based on proposed model, the effects of heterogeneity at different scale on micromechanical behavior and induced macroscopic fractures are examined. From the numerical results, the microcrack will be more inclined to form at the grain weaker interface. The conventional simulator with homogeneous assumption is not applicable for highly heterogeneous shale formation.« less

  13. [Bony injuries of the shoulder girdle in snowboarding].

    PubMed

    Ehrnthaller, C; Gebhard, F; Imhoff, A B; Braun, S

    2014-01-01

    The fracture of the clavicle is the second most common fracture in snowboarding after the distal radius fracture. Nonsurgical treatment is frequently the treatment of first choice. For displaced fractures, surgical treatment is recommended. In general, internal fixation can be performed with a plate osteosynthesis or an intramedullary nail. Clinical studies were able to show similar and even slightly better functional results of the intramedullary nail in comparison to plate osteosynthesis. Because of less surgical trauma and better cosmetic results, intramedullary systems are increasingly preferred. Lateral clavicular fractures are more complex regarding surgical treatment due to their potential for concomitant ligamentous injuries. The hooked plate shows good clinical results with the advantage of addressing the fracture as well as the ligament injury in one step. The limitation of mobility during the first few postoperative weeks is the technique's main disadvantage. Ligament reconstruction with suture pulley systems as a stand-alone treatment or in combination with a locking plate osteosythesis are increasingly used due to their excellent clinical results with early postoperative mobilization.

  14. Arthroscopic study of injuries in articular fractures of distal radius extremity

    PubMed Central

    Araf, Marcelo; Mattar, Rames

    2014-01-01

    OBJECTIVE: To analyze the incidence of wrist ligament and cartilage associated fractures of the distal radius, through arthroscopy, correlating with AO/ASIF classification. METHODS: Thirty patients aged between 20 and 50 years old, with closed fracture from groups B and C according to AO/ASIF classification were selected. All of them were submitted to wrist arthroscopy to address intra-articular injuries and reduction and osteosynthesis of the fracture. RESULTS: A high incidence of intra-articular injuries was noticed, and 76.6% of them presented injury of the triangular fibrocartilage complex, 36.6% of the intrinsic scapholunate ligament, 6.6% of the intrinsic triquetrolunate ligament, and 33% articular cartilage injury larger than three millimeters. Patients with fractures from type C according to AO/ASIF classification presented a higher incidence of ligament injuries. CONCLUSION: There is no relationship between the presence of chondral injury and the AO/ASIF classification of the fractures in the cases reported in this study. Level of Evidence III, Non Randomized Controlled Trial. PMID:25061421

  15. An elasto-plastic fracture mechanics based model for assessment of hydride embrittlement in zircaloy cladding tubes

    NASA Astrophysics Data System (ADS)

    Nilsson, Karl-Fredrik; Jakšić, Nikola; Vokál, Vratko

    2010-01-01

    This paper describes a finite element based fracture mechanics model to assess how hydrides affect the integrity of zircaloy cladding tubes. The hydrides are assumed to fracture at a low load whereas the propagation of the fractured hydrides in the matrix material and failure of the tube is controlled by non-linear fracture mechanics and plastic collapse of the ligaments between the hydrides. The paper quantifies the relative importance of hydride geometrical parameters such as size, orientation and location of individual hydrides and interaction between adjacent hydrides. The paper also presents analyses for some different and representative multi-hydride configurations. The model is adaptable to general and complex crack configurations and can therefore be used to assess realistic hydride configurations. The mechanism of cladding failure is by plastic collapse of ligaments between interacting fractured hydrides. The results show that the integrity can be drastically reduced when several radial hydrides form continuous patterns.

  16. Reduced survival for uncemented compared to cemented total hip arthroplasty after operatively treated acetabular fractures.

    PubMed

    Clarke-Jenssen, John; Westberg, Marianne; Røise, Olav; Storeggen, Stein Arne Øvre; Bere, Tone; Silberg, Ingunn; Madsen, Jan Erik

    2017-11-01

    Post traumatic arthritis and avascular necrosis of the femoral head are common complications after operatively treated acetabular fractures. This may cause severe disabilities for the patient, necessitating a total hip arthroplasty. Even though an arthroplasty may provide good symptomatic relief, the long-term results are more uncertain and no consensus exists according to preferred prosthetic designs. With this cohort study, we aimed to investigate the medium to long term arthroplasty survival and clinical results of total hip arthroplasty after operatively treated acetabular fractures. We included 52 patients treated with a secondary total hip arthroplasty at a median of 2.4 (0.1-14.1) years after an operatively treated acetabular fracture. The median age was 54 (11-82) years. Cemented arthroplasty was used for 33 patients, 10 patients had an uncemented arthroplasty and 9 patients received a hybrid arthroplasty. Average follow up was 8.0 (SD 5.0) years. Ten-year revision free arthroplasty survival was 79%. Uncemented arthroplasties had a significantly worse 10-year survival of 57%. Arthroplasties performed at a centre without a pelvic fracture service also had a significantly worse 10-years survival of 51%. Cox regression showed similar results with an 8-fold increase in risk of revision for both uncemented arthroplasties and operations performed at a non-pelvic trauma centre. Total hip arthroplasty secondary to an operatively treated acetabular fracture provides good symptomatic relief. These patients are, however, complex cases and are probably best treated at specialist centres with both pelvic trauma surgeons and arthroplasty surgeons proficient in complex revisions present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. EARLY OR DELAYED SURGICAL TREATMENT IN COMPOUND LIMB FRACTURES DUE TO HIGH VELOCITY MISSILE INJURIES: A 5-YEAR RETROSPECTIVE STUDY FROM MEDICAL CITY IN BAGHDAD

    PubMed Central

    Al-Hilli, Ali Bakir; Salih, Dheyaa Saeed

    2010-01-01

    Background Compound limb fractures due to high-velocity missiles are complex and usually associated with multiple other injuries. These can occur in both military and civilian settings. Highvelocity missiles are presently used by terrorists worldwide. Early surgical debridement and skeletal fixation are the gold standards in managing these injuries, but data supporting these recommendations are lacking. Aim of the study Our aim was to determine the relationship between time (the time of injury to the time of surgical treatment) and the rate of deep infection in patients treated in Medical City, Baghdad, Iraq due to terrorist activity from 2004-2008. Design This is a retrospective review of a series of open limb fractures. Patients and method A total of 102 civilian patients with 114 limb fractures due to high-velocity missile injuries were selected for this study from Medical City records. Patients were followed in the outpatient department in Medical City Teaching Complex both clinically and radiologically. Results Surgical treatment was accomplished in less than six hours from time of injury in group A (55 fractures, 48.4%) and more than six hours in group B (59 fractures, 51.7%). The infection rate for group A was 30.9% and group B was 23.7%. Conclusion A very high infection rate was noted for these injuries, and there was no increase in the rate of deep infection in patients treated more than six hours after the injury. PMID:21045979

  18. COMPLEX MANAGEMENT OF FRAILTY FRACTURES--CASE REPORT.

    PubMed

    Costescu, Elena Puin; Dronic, Aliona; Alexa, Loana Dana; Alexa, O

    2016-01-01

    Frailty fractures encompass pelvic ring fractures in the elderly--a condition more frequently encountered in women, usually with pre-existing osteoporosis. The incidence of these fractures is increasing, following the increase in average life expectancy. Most of the times, they are the result of a minor injury, of which the patient has little or no recollection; the clinical signs and symptoms, radiological changes and the degree of fracture stability vary greatly. As such, there is a wide range of therapeutic options and one of the most important decisions for the physician is choosing between surgery and conservative treatment. We present the case of an elderly female patient with multiple pelvic ring fractures, and a medical history of cardiovascular disease and osteoporosis; the orthopedic examination recommended conservative treatment which was carried out in the Geriatric Clinic of the "Dr. C.I. Parhon" Hospital. Following the complete physical examination and through geriatric evaluation, a complex therapeutic plan was devised, which included: recovery through physiotherapy, adequate nutrition, psychological support, treatment of the cardiovascular comorbidities and prevention of the consequences of extended bed rest. The treatment lasted for 60 days and the outcome was favorable: decreased bone frailty, mainly through preserving muscle tone and osteoarticular function, correction of malnutrition, improvement of depression and partial recovery of patient's mobility; the results of our therapy made it possible for the patient to return home, where she leaves alone. She will need help with daily household chores, but she intends to continue the recovery therapy as means of increasing her quality of life and independence.

  19. Lattice Boltzmann simulation of CO2 reactive transport in network fractured media

    NASA Astrophysics Data System (ADS)

    Tian, Zhiwei; Wang, Junye

    2017-08-01

    Carbon dioxide (CO2) geological sequestration plays an important role in mitigating CO2 emissions for climate change. Understanding interactions of the injected CO2 with network fractures and hydrocarbons is key for optimizing and controlling CO2 geological sequestration and evaluating its risks to ground water. However, there is a well-known, difficult process in simulating the dynamic interaction of fracture-matrix, such as dynamic change of matrix porosity, unsaturated processes in rock matrix, and effect of rock mineral properties. In this paper, we develop an explicit model of the fracture-matrix interactions using multilayer bounce-back treatment as a first attempt to simulate CO2 reactive transport in network fractured media through coupling the Dardis's LBM porous model for a new interface treatment. Two kinds of typical fracture networks in porous media are simulated: straight cross network fractures and interleaving network fractures. The reaction rate and porosity distribution are illustrated and well-matched patterns are found. The species concentration distribution and evolution with time steps are also analyzed and compared with different transport properties. The results demonstrate the capability of this model to investigate the complex processes of CO2 geological injection and reactive transport in network fractured media, such as dynamic change of matrix porosity.

  20. Periarticular Fractures of the Knee in Polytrauma Patients

    PubMed Central

    Bertrand, M.L.; Andrés-Cano, P.; Pascual-López, F.J.

    2015-01-01

    Periarticular fractures around the knee are a challenge for the orthopaedic surgeon. When these fractures are presented in the context of a multiple trauma patient, they are even more difficult to manage because the treatment approach depends not only on the fracture itself, but also on the patient’s general condition. These fractures, caused by high-energy trauma, present complex fracture patterns with severe comminution and major loss of articular congruity, and are often associated with vascular and nerve complications, particularly in the proximal tibia, due to its anatomical features with poor myocutaneous coverage. They are almost always accompanied by soft tissue injury. The management of polytrauma patients requires a multidisciplinary team and accurate systemic stabilization of the patient before undertaking orthopaedic treatment. These fractures are usually addressed sequentially, either according to the general condition of the patient or to the local characteristics of the lesions. In recent decades, various fixation methods have been proposed, but there is still no consensus as to the ideal method for stabilizing these fractures. In this paper, we describe the general characteristics of these fractures, the stabilization methods traditionally used and those that have been developed in recent years, and discuss the treatment sequences proposed as most suitable for the management of these injuries. PMID:26312118

  1. Fatal carotid dissection after blunt head trauma.

    PubMed

    Tartara, F; Regolo, P; Servadei, F; Versari, P P; Giovanelli, M

    2000-06-01

    Occurrence of internal carotid artery injuries associated with skull base fracture has been reported. A. report a case of fatal intracranial carotid dissection related to petrous fracture involving the carotid canal. Identification of carotid lesions may be difficult and generally related to appearance of unexpected neurological deficit. Skull base fractures may be considered an indirect sign for detection of vascular injury. Patterns of the fracture are of paramount importance; routine CT scan may fail to detect basilar fractures and high definition fine-cut CT scan should be executed to carefully identify and evaluate fractures. Temporal and sphenoid bone fractures are common in head trauma and involvement of the course of the carotid artery is frequent. The involvement of the intracranial carotid artery course represents a direct risk factor for lesions of the petrous, lacerum and cavernous segments of the carotid artery. Early diagnosis of post-traumatic vascular injury may lead to prognosis improvement because of effectiveness of heparin anticoagulant therapy. Then vascular screening is recommendable in cases with complex fractures of the skull base and particularly fracturing along the course of the carotid artery. Magnetic resonance angiography may be considered the first line diagnostic tools for vascular screening. Angiography may be reserved for patients with a proven lesion or rapid neurological deterioration taking into account the possibility of interventional treatment.

  2. Maxillofacial fractures among Sudanese children at Khartoum Dental Teaching Hospital.

    PubMed

    Almahdi, Hatim M; Higzi, Mohammed A

    2016-02-23

    Maxillofacial fractures in children are less frequent compared to adults but result in special complications affecting the growth, function and esthetics. The study aimed at assessing the characteristics and the pattern of facial fractures among children seen at Khartoum Teaching Dental Hospital (KTDH). The study included 390 patients presenting with maxillofacial trauma at KTDH during a year period (2010-2011). A total of 390 patients, diagnosed with facial fractures, were seen at KTDH; 14.1% (55) were children below 16 years of age with the mean age of 10 years (SD ± 3.9). The ratio of males to females was 2.2:1. Most fractures were due to road traffic accidents (RTA) 56.4%, followed by daily living activities 21.8% and assault 16.4%. The most prevalent anatomic sites of fractures were mandible 77%; combination fractures i.e. more than one site 32.7% and zygomatic-complex (13.5%). Concomitant injuries were found in 9.1%. Almost half of the patients were managed conservatively 49.1%, closed reduction 34.5% and surgical open reduction 16.4%. The findings of this study indicated that pediatric facial fractures constitute 14.1% of the total number of facial fractures. RTA was the main cause, which should be considered in legislative and preventive strategies.

  3. Profile and procedures for fractures among 1323 fracture patients from the 2010 Yushu earthquake, China.

    PubMed

    Kang, Peng; Tang, Bihan; Liu, Yuan; Liu, Xu; Shen, Yan; Liu, Zhipeng; Yang, Hongyang; Zhang, Lulu

    2016-11-01

    The injuries caused by earthquakes are often complex and of various patterns. Our study included all fracture inpatients from the Yushu earthquake (1323 in total), to learn more about the incidence and distribution of fractures during earthquakes. A retrospective study of the clinical characteristics of hospitalized fracture patients after the 2010 Yushu earthquake was conducted from December 20 to 25, 2010.We reviewed medical records of hospitalized patients who had been evacuated from the Yushu earthquake area between April 14 and June 15, 2010, from 57 hospitals, and also reviewed more than 100 documents assembled from daily medical rescue and disease prevention reports submitted by the frontline rescue organizations. In total, 78.0% of fracture patients were admitted to the hospital within 3 days after the earthquake. There were 1323 patients who presented with 1539 fractures. The most common fracture occurred in the lower limbs, followed by spinal, pelvic, and shoulder-upper limb fractures. The end of the thoracic vertebra and the lumbar vertebra were the high-risk sites for vertebral fractures. A total of 38 patients became paraplegic. A 2-level spatial clustering was detected among the 193 patients presenting with 2 fractures. Analysis profiles of the injuries and clinical features of patients with earthquake-related fractures will positively impact rescue efforts and the treatment of fracture injuries caused by possible future natural disasters. We should assemble orthopedic-related medications and surgical equipment, and allocate them promptly after a major earthquake. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Molecular Identification of Human Fungal Pathogens

    DTIC Science & Technology

    2011-03-01

    of the right lower tibia and fibula revealed nonenhancing edema of the skin and subcutaneous fat involving the medial distal right lower leg without...military hospital in Iraq and taken immediately to the operating room for complex pelvic fracture debridement and fixation, right lower extremity...patient’s comorbidities—which included acute kidney injury secondary to rhabdomyolysis, multiple fractures requiring surgical intervention, and pro

  5. [The use of titanium nickelide devices in treating fractures of the zygomatico-orbital complex].

    PubMed

    Medvedev, Iu A; Sivolapov, K A

    1993-01-01

    The authors analyze the results of surgical treatment of 78 patients with zygomatico-orbital injuries. Mini-cramps and mini-plates of titanium nickelide with thermomechanical memory were employed for fracture fixation. Surgical strategy based on osteosynthesis with the use of such devices provides a reliable fixation of bone fragments and makes the operation less traumatic.

  6. Fracture mechanics of cellular glass

    NASA Technical Reports Server (NTRS)

    Zwissler, J. G.; Adams, M. A.

    1981-01-01

    The fracture mechanics of cellular glasses (for the structural substrate of mirrored glass for solr concentrator reflecting panels) are discussed. Commercial and developmental cellular glasses were tested and analyzed using standard testing techniques and models developed from linear fracture mechanics. Two models describing the fracture behavior of these materials were developed. Slow crack growth behavior in cellular glass was found to be more complex than that encountered in dense glasses or ceramics. The crack velocity was found to be strongly dependent upon water vapor transport to the tip of the moving crack. The existence of a static fatigue limit was not conclusively established, however, it is speculated that slow crack growth behavior in Region 1 may be slower, by orders of magnitude, than that found in dense glasses.

  7. Intraoperative fluoroscopic evaluation of screw placement during pelvic and acetabular surgery.

    PubMed

    Yi, Chengla; Burns, Sean; Hak, David J

    2014-01-01

    The surgical treatment of pelvic and acetabular fractures can be technically challenging. Various techniques are available for the reconstruction of pelvic and acetabular fractures. Less invasive percutaneous fracture stabilization techniques, with closed reduction or limited open reduction, have been developed and are gaining popularity in the management of pelvic and acetabular fractures. These techniques require knowledge and interpretation of various fluoroscopic images to ensure appropriate and safe screw placement. Given the anatomic complexity of the intrapelvic structures and the 2-dimensional nature of standard fluoroscopy, multiple images oriented in different planes are needed to assess the accuracy of guide wire and screw placement. This article reviews the fluoroscopic imaging of common screw orientations during pelvic and acetabular surgery.

  8. Flow Through Cement Fracture Under Geological Carbon Sequestration Conditions: Critical Residence Time as a Unifying Parameter for Fracture Opening or Self-Sealing Behavior

    NASA Astrophysics Data System (ADS)

    Li, L.; Brunet, J. P. L.; Karpyn, Z.; Huerta, N. J.

    2016-12-01

    During geological carbon sequestration (GCS) large quantities of CO2 are injected in underground formations. Cement fractures represent preferential leakage pathways in abandoned wells upon exposure to CO2-rich fluid. Contrasting self- healing and fracture opening behavior have been observed while a unifying framework is still missing. The modelling of this process is challenging as it involves complex chemical, mechanical and transport interactions. We developed a process-based reactive transport model that explicitly simulates flow and multi-component reactive transport in fractured cement by reproducing experimental observations of sharp flow rate reduction during exposure to carbonated water. Mechanical interactions have not been included. The simulation shows a similar reaction network as in diffusion-controlled systems without flow. That is, CO2-rich water induced portlandite dissolution, releasing calcium that further reacted with carbonate to form calcite. This created localized changes in porosity and permeability inducing large differences in the long term response of the system through a complex positive feedback loop (e.g., a decrease in local permeability induces a decrease in flow that in turn amplifies the precipitation of calcite through a reduced acidic brine flow). The calibrated model was used to generate 250 numerical experiments of CO2-flooding in cement fractures with varying initial hydraulic apertures (b) and residence times (τ) defined as the ratio of fracture volume over flow rate. A long τ leads to slow replenishment of carbonated water, calcite precipitation, and self-sealing. The opposite occurs when τ is small with short fractures and fast flow rates. Simulation results indicate that a critical residence time τc - the minimum τ required for self-sealing -divides the conditions that trigger the diverging opening and self-sealing behavior. The τc value depends on the initial aperture size (see figure). Among the 250 simulated fracture cases, significant changes in effective permeability - self-healing or opening - typically occurs within hours to a day, thus providing a supporting argument for the extrapolation of short-term laboratory observations (hours to months) to long-term predictions at relevant GCS time scales (years to hundreds of years).

  9. Measuring the hydraulic fracture-induced deformation of reservoirs and adjacent rocks employing a deeply buried inclinometer array: GRI/DOE multi-site project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Branagan, P.T.; Warpinski, N.R.; Engler, B.

    A vertical inclinometer array consisting of six biaxial tiltmeters was cemented behind pipe at depths between 4,273 and 4,628 ft. This wide-aperture array provided real-time tilt profiles corresponding to a series of seven hydraulic fractures being conducted in a nearby offset well in a fluvial sandstone reservoir. Array profiles for three KCl water fracs indicated that height growth was confined to the gross thickness of the reservoir despite extensive fracture length extension. Long-term monitoring of the array suggests that a substantial residual frac: width remained long after fracture closure occurred. For two 400-bbl linear gel minifracs, some height growth wasmore » observed but it was not extensive. Tilt amplitudes related to expanded frac widths were found to increase as would be expected with these thicker frac fluids. When cross-linker and proppant were included in the last fracture, tilt-derived heights were seen to grow rapidly extending into the bounding layers as the more complex fluids entered the fracture system. This inclinometer array was one of several independent, yet complimentary, fracture diagnostics tools that included crosswell multilevel microseismic arrays, FRACPRO{reg_sign} and a remote fracture intersection well. Their purpose was to provide integrated field-scale data regarding hydraulic fracture dynamics and geometry that would be used to construct accurate fracture mapping and diagnostic techniques.« less

  10. Why do nickel-titanium archwires fracture intraorally? Fractographic analysis and failure mechanism of in-vivo fractured wires.

    PubMed

    Zinelis, Spiros; Eliades, Theodore; Pandis, Nikolaos; Eliades, George; Bourauel, Christoph

    2007-07-01

    The aim of this study was to characterize intraorally fractured nickel-titanium (Ni-Ti) archwires, determine the type of fracture, assess changes in the alloy's hardness and structure, and propose a mechanism of failure. Eleven Ni-Ti SE 200 and 19 copper-Ni-Ti (both, Ormco, Glendora, Calif) intraorally fractured archwires were collected. The location of fracture (anterior or posterior), wire type, cross section, and period of service before fracture were recorded. The retrieved wires and brand-, type-, and size-matched specimens of unused wires were subjected to scanning electron microscopy to assess the fracture type and morphological variation of fracture site of retrieved specimens, and to Vickers hardness (HV200) testing to investigate the hardness of as-received and in-vivo fractured specimens. Fracture site distribution was statistically analyzed with the chi-square test (alpha = 0.05), whereas the results of the hardness testing were analyzed with 2-way ANOVA with state (control vs in-vivo fractured) and composition (Ni-Ti SE vs copper-Ni-Ti) serving as discriminating variables and the Student-Newman-Keuls test at the 95% confidence level. The fracture site distribution showed a preferential location at the midspan between the premolar and the molar, suggesting that masticatory forces and complex loading during engagement of the wire to the bracket slot and potential intraoral aging might account for fracture incidence. All retrieved wires had the distinct features of brittle fracture without plastic deformation or crack propagation, whereas no increase in hardness was observed for the retrieved specimens. Most fractures sites were in the posterior region of the arch, probably because of the high-magnitude masticatory forces. Brittle fracture without plastic deformation was observed in most Ni-Ti wires regardless of archwire composition. There was no increase in the hardness of the intraorally exposed specimens regardless of wire type. This contradicts previous in-vitro studies and rules out hydrogen embrittlement as the cause of fracture.

  11. Comparison between results of detailed tectonic studies on borehole core vs microresistivity images of borehole wall from gas-bearing shale complexes, Baltic Basin, Poland.

    NASA Astrophysics Data System (ADS)

    Bobek, Kinga; Jarosiński, Marek; Pachytel, Radomir

    2017-04-01

    Structural analysis of borehole core and microresistivity images yield an information about geometry of natural fracture network and their potential importance for reservoir stimulation. Density of natural fractures and their orientation in respect to the maximum horizontal stress has crucial meaning for hydraulic fractures propagation in unconventional reservoirs. We have investigated several hundred meters of continuous borehole core and corresponding microresistivity images (mostly XRMI) from six boreholes in the Pomeranian part of the Early Paleozoic Baltic Basin. In general, our results challenge the question about representatives of statistics based on structural analyses on a small shale volume represented by borehole core or borehole wall images and credibility of different sets of data. Most frequently, fractures observed in both XRMI and cores are steep, small strata-bound fractures and veins with minor mechanical aperture (0,1 mm in average). These veins create an orthogonal joint system, locally disturbed by fractures associated with normal or by gently dipping thrust faults. Mean fractures' height keeps in a range between 30-50 cm. Fracture density differs significantly among boreholes and Consistent Lithological Units (CLUs) but the most frequent means falls in a range 2-4 m-1. We have also payed an attention to bedding planes due to their expected coupling with natural fractures and their role as structural barriers for vertical fracture propagation. We aimed in construction for each CLU the so-called "mean brick", which size is limited by an average distance between two principal joint sets and between bedding fractures. In our study we have found out a discrepancy between structural profiles based on XRMI and core interpretation. For some CLUs joint fractures densities, are higher in cores than in XRMI. In this case, numerous small fractures were not recorded due to the limits of XRMI resolution. However, the most veins with aperture 0,1 mm, cemented with calcite, were clearly visible in scanner image. We have also observed significantly lower density of veins in core than in the XRMI that occurs systematically in one formation enriched with carbonate and dolomite. In this case, veins are not fractured in core and obliterated for bare eye by dolomitization, but are still contrastive in respect of electric resistance. Calculated density of bedding planes per 1 meter reveals systematically higher density of fractures observed on core than in the XRMI (depicted automatically by interpretation program). This difference may come from additional fracking due to relaxation of borehole core while recovery. Comparison of vertical joint fractures density with thickness of mechanical beds shows either lack of significant trends or a negative correlation (greater density of bedding fractures correspond to lower density of joints). This result, obtained for shale complexes contradict that derived for sandstone or limestone. Boundary between CLUs are visible on both: joint and bedding fracture density profiles. Considering small-scale faults and slickensides we have obtained good agreement between results of core and scanner interpretation. This study in the frame of ShaleMech Project funded by Polish Committee for Scientific Research is in progress and the results are preliminary.

  12. Tectonic analysis of folds in the Colorado plateau of Arizona

    NASA Technical Reports Server (NTRS)

    Davis, G. H.

    1975-01-01

    Structural mapping and analysis of folds in Phanerozoic rocks in northern Arizona, using LANDSAT-1 imagery, yielded information for a tectonic model useful in identifying regional fracture zones within the Colorado Plateau tectonic province. Since the monoclines within the province developed as a response to differential movements of basement blocks along high-angle faults, the monoclinal fold pattern records the position and trend of many elements of the regional fracture system. The Plateau is divided into a mosaic of complex, polyhedral crustal blocks whose steeply dipping faces correspond to major fracture zones. Zones of convergence and changes in the trend of the monoclinal traces reveal the corners of the blocks. Igneous (and salt) diapirs have been emplaced into many of the designated zones of crustal weakness. As loci of major fracturing, folding, and probably facies changes, the fractures exert control on the entrapment of oil and gas.

  13. Patterns of Maxillofacial Fractures in Uttar Pradesh, India

    PubMed Central

    Agarwal, Padmanidhi; Mehrotra, Divya; Agarwal, Rajul; Kumar, Sumit; Pandey, Rahul

    2016-01-01

    This study aimed to obtain dependable epidemiologic data of the variation in cause and characteristics of maxillofacial fractures by identifying, describing, and quantifying trauma. This retrospective study was conducted in the state of Uttar Pradesh, India, over 1 year, based on a systematic computer-assisted database search from March 2015 to March 2016 for maxillofacial fractures. The demographics, etiology, geographic distribution, date of injury, site and number of fractures, and type of intervention were recorded for each. The study population consisted of 1,000 patients with 1,543 fractures. The male:female ratio was 8:1. A peak incidence of fractures was seen in the third decade (mean age: 30.3) with maximum patients younger than 40 years (80.8%). The incidence of fractures was highest in spring (42.9%). Road traffic accidents were the most common cause of trauma (64.4%) and mainly involved two wheelers (60.2%). Single-site fractures were most common. Mostly zygomatic (45.1%) and mandibular fractures (44.4%) were encountered, accounting for approximately 90% of all fractures. The main site of mandibular fractures was the body (34.4%); 46.2% of fractures underwent open reduction and internal fixation (ORIF) while 53.8% were treated by closed methods. The study provides important data to contrive future plans for injury prevention. The trend of most traffic-related injuries continues with the increasing traffic on roads. Zygomatic complex and mandibular fractures remain the most frequent. The major populations at risk are young men and those driving two wheelers. The use of helmets could achieve a large reduction in maxillofacial fractures. Awareness for preventive measures and safety guidelines should be propagated and legislation on traffic rules strictly reinforced. PMID:28210408

  14. Modelling CO2 flow in naturally fractured geological media using MINC and multiple subregion upscaling procedure

    NASA Astrophysics Data System (ADS)

    Tatomir, Alexandru Bogdan A. C.; Flemisch, Bernd; Class, Holger; Helmig, Rainer; Sauter, Martin

    2017-04-01

    Geological storage of CO2 represents one viable solution to reduce greenhouse gas emission in the atmosphere. Potential leakage of CO2 storage can occur through networks of interconnected fractures. The geometrical complexity of these networks is often very high involving fractures occurring at various scales and having hierarchical structures. Such multiphase flow systems are usually hard to solve with a discrete fracture modelling (DFM) approach. Therefore, continuum fracture models assuming average properties are usually preferred. The multiple interacting continua (MINC) model is an extension of the classic double porosity model (Warren and Root, 1963) which accounts for the non-linear behaviour of the matrix-fracture interactions. For CO2 storage applications the transient representation of the inter-porosity two phase flow plays an important role. This study tests the accuracy and computational efficiency of the MINC method complemented with the multiple sub-region (MSR) upscaling procedure versus the DFM. The two phase flow MINC simulator is implemented in the free-open source numerical toolbox DuMux (www.dumux.org). The MSR (Gong et al., 2009) determines the inter-porosity terms by solving simplified local single-phase flow problems. The DFM is considered as the reference solution. The numerical examples consider a quasi-1D reservoir with a quadratic fracture system , a five-spot radial symmetric reservoir, and a completely random generated fracture system. Keywords: MINC, upscaling, two-phase flow, fractured porous media, discrete fracture model, continuum fracture model

  15. Misdiagnosis of Talar Body or Neck Fractures as Ankle Sprains in Low Energy Traumas

    PubMed Central

    Young, Ki-Won; Kim, Jin-Su; Cho, Hun-Ki; Choo, Ho-Sik; Park, Jang-Ho

    2016-01-01

    Background The talus has a very complex anatomical morphology and is mainly fractured by a major force caused by a fall or a traffic accident. Therefore, a talus fracture is not common. However, many recent reports have shown that minor injuries, such as sprains and slips during sports activities, can induce a talar fracture especially in the lateral or posterior process. Still, fractures to the main parts of the talus (neck and body) after ankle sprains have not been reported as occult fractures. Methods Of the total 102 cases from January 2005 to December 2012, 7 patients had confirmed cases of missed/delayed diagnosis of a talus body or neck fracture and were included in the study population. If available, medical records, X-rays, computed tomography scans, and magnetic resonance imaging of the confirmed cases were retrospectively reviewed and analyzed. Results In the 7-patient population, there were 3 talar neck fractures and 4 talar body fractures (coronal shearing type). The mechanisms of injuries were all low energy trauma episodes. The causes of the injuries included twisting of the ankle during climbing (n = 2), jumping to the ground from a 1-m high wall (n = 2), and twisting of the ankle during daily activities (n = 3). Conclusions A talar body fracture and a talar neck fracture should be considered in the differential diagnosis of patients with acute and chronic ankle pain after a minor ankle injury. PMID:27583114

  16. Parathyroid hormone and bone healing.

    PubMed

    Ellegaard, M; Jørgensen, N R; Schwarz, P

    2010-07-01

    Fracture healing is a complex process, and a significant number of fractures are complicated by impaired healing and non-union. Impaired healing is prevalent in certain risk groups, such as the elderly, osteoporotics, people with malnutrition, and women after menopause. Currently, no pharmacological treatments are available. There is therefore an unmet need for medications that can stimulate bone healing. Parathyroid hormone (PTH) is the first bone anabolic drug approved for the treatment of osteoporosis, and intriguingly a number of animal studies suggest that PTH could be beneficial in the treatment of fractures and could thus be a potentially new treatment option for induction of fracture healing in humans. Furthermore, fractures in animals with experimental conditions of impaired healing such as aging, estrogen withdrawal, and malnutrition can heal in an expedited manner after PTH treatment. Interestingly, fractures occurring at both cancellous and cortical sites can be treated successfully, indicating that both osteoporotic and nonosteoporotic fractures can be the target of PTH-induced healing. Finally, the data suggest that PTH partly prevents the delay in fracture healing caused by aging. Recently, the first randomized, controlled clinical trial investigating the effect of PTH on fracture healing was published, indicating a possible clinical benefit of PTH treatment in inducing fracture healing. The aim of this article is therefore to review the evidence for the potential of PTH in bone healing, including the underlying mechanisms for this, and to provide recommendations for the clinical testing and use of PTH in the treatment of impaired fracture healing in humans.

  17. Models of tibial fracture healing in normal and Nf1-deficient mice.

    PubMed

    Schindeler, Aaron; Morse, Alyson; Harry, Lorraine; Godfrey, Craig; Mikulec, Kathy; McDonald, Michelle; Gasser, Jürg A; Little, David G

    2008-08-01

    Delayed union and nonunion are common complications associated with tibial fractures, particularly in the distal tibia. Existing mouse tibial fracture models are typically closed and middiaphyseal, and thus poorly recapitulate the prevailing conditions following surgery on a human open distal tibial fracture. This report describes our development of two open tibial fracture models in the mouse, where the bone is broken either in the tibial midshaft (mid-diaphysis) or in the distal tibia. Fractures in the distal tibial model showed delayed repair compared to fractures in the tibial midshaft. These tibial fracture models were applied to both wild-type and Nf1-deficient (Nf1+/-) mice. Bone repair has been reported to be exceptionally problematic in human NF1 patients, and these patients can also spontaneously develop tibial nonunions (known as congenital pseudarthrosis of the tibia), which are recalcitrant to even vigorous intervention. pQCT analysis confirmed no fundamental differences in cortical or cancellous bone in Nf1-deficient mouse tibiae compared to wild-type mice. Although no difference in bone healing was seen in the tibial midshaft fracture model, the healing of distal tibial fractures was found to be impaired in Nf1+/- mice. The histological features associated with nonunited Nf1+/- fractures were variable, but included delayed cartilage removal, disproportionate fibrous invasion, insufficient new bone anabolism, and excessive catabolism. These findings imply that the pathology of tibial pseudarthrosis in human NF1 is complex and likely to be multifactorial.

  18. [Treatment of metaphyseal fractures of shin bones by the method of blocking osteosynthesis].

    PubMed

    Neverov, V A; Khromov, A A; Cherniaev, S N; Egorov, K S; Shebarshov, A L

    2008-01-01

    The proposed method of reposition and polyaxial stabilization of fragments for intramedullary meallosynthesis of fractures of long tubular bones allows blocking osteosynthesis to be successfully used in treatment of complex metaphyseal fractures of shin bones. It results in strong fixation of the fragments, makes it possible to successfully eliminate residual deformities after introduction of the nail and to avoid the development of them in future under the influence of loading. The method provides early functioning of the interfacing joints, early axial loading, shorter period of disability, the absence of external immobilization.

  19. On the Fracture Toughness and Stable Crack Growth in Shape Memory Alloys Under Combined Thermomechanical Loading

    NASA Astrophysics Data System (ADS)

    Jape, Sameer Sanjay

    Advanced multifunctional materials such as shape memory alloys (SMAs) offer unprecedented improvement over conventional materials when utilized as high power output solid-state actuators in a plethora of engineering applications, viz. aerospace, automotive, oil and gas exploration, etc., replacing complex multi-component assemblies with compact single-piece adaptive components. These potential applications stem from the material's ability to produce large recoverable actuation strains when subjected to combined thermomechanical loads, via a diffusionless solid-to-solid phase transition between high-temperature cubic austenite and low-temperature monoclinic martensite crystalline phases. To ensure reliable design, functioning and durability of SMA-based actuators, it is imperative to develop a thorough scientific knowledge base and understanding about their fracture properties i.e. crack-initiation and growth during thermal actuation, vis-a-vis the phase transformation metrics (i.e. transformation strains, hysteresis, and temperatures, critical stresses for phase transformation, etc.) and microstructural features (grain size, precipitates, and texture). Systematic experimental and analytical investigation of SMA fracture response based on known theories and methodologies is posed with significant challenges due to the inherent complexity in SMA thermomechanical constitutive response arising out of the shape memory and pseudoelastic effects, martensite detwinning and variant reorientation, thermomechanical coupling, and transformation induced plasticity (TRIP). In this study, a numerical analysis is presented that addresses the fundamental need to study fracture in SMAs in the presence of aforementioned complexities. Finite element modeling with an energetics based fracture toughness criterion and SMA thermomechanical behavior with nonlinearities from thermomechanical coupling and TRIP was conducted. A specific analysis of a prototype boundary value fracture problem yielded results similar to those obtained experimentally, viz. stable crack growth with transformation toughening, dependence of failure cycle on bias load and catastrophic failure during cooling, and are explained using classical fracture mechanics theories. Influence of TRIP as a monotonically accumulating irrecoverable plastic strain on the crack-tip mechanical fields in case of stationary and advancing cracks is also investigated using the same computational tools. Thermomechanical coupling in shape memory alloys, which is an important factor when utilized as solid-state actuators manifests itself through the generation and absorption of latent of transformation and leads to non-uniform temperature distribution. The effect of this coupling vis-a-vis the mechanics of static and advancing cracks is also analyzed using the energetics based approach.

  20. Brittle structures and their role in controlling porosity and permeability in a complex Precambrian crystalline-rock aquifer system in the Colorado Rocky Mountain front range

    USGS Publications Warehouse

    Caine, Jonathan S.; Tomusiak, S.R.A.

    2003-01-01

    Expansion of the Denver metropolitan area has resulted in substantial residential development in the foothills of the Rocky Mountain Front Range. This type of sub-urban growth, characteristic of much of the semiarid intermountain west, often relies on groundwater from individual domestic wells and is exemplified in the Turkey Creek watershed. The watershed is underlain by complexly deformed and fractured crystalline bedrock in which groundwater resources are poorly understood, and concerns regarding groundwater mining and degradation have arisen. As part of a pilot project to establish quantitative bounds on the groundwater resource, an outcrop-based geologic characterization and numerical modeling study of the brittle structures and their controls on the flow system was initiated. Existing data suggest that ground-water storage, flow, and contaminant transport are primarily controlled by a heterogeneous array of fracture networks. Inspections of well-permit data and field observations led to a conceptual model in which three dominant lithologic groups underlying sparse surface deposits form the aquifer system-metamorphic rocks, a complex array of granitic intrusive rocks, and major brittle fault zones. Pervasive but variable jointing of each lithologic group forms the "background" permeability structure and is an important component of the bulk storage capacity. This "background" is cut by brittle fault zones of varying structural styles and by pegmatite dikes, both with much higher fracture intensities relative to "background" that likely make them spatially complex conduits. Probabilistic, discrete-fracture-network and finite-element modeling was used to estimate porosity and permeability at the outcrop scale using fracture network data collected in the field. The models were conditioned to limited aquifer test and borehole geophysical data and give insight into the relative hydraulic properties between locations and geologic controls on storage and flow. Results from this study reveal a complex aquifer system in which the upper limits on estimated hydraulic properties suggest limited storage capacity and permeability as compared with many sedimentary-rock and surficial-deposit aquifers.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmad Ghassemi

    Geothermal energy is recovered by circulating water through heat exchange areas within a hot rock mass. Geothermal reservoir rock masses generally consist of igneous and metamorphic rocks that have low matrix permeability. Therefore, cracks and fractures play a significant role in extraction of geothermal energy by providing the major pathways for fluid flow and heat exchange. Therefore, knowledge of the conditions leading to formation of fractures and fracture networks is of paramount importance. Furthermore, in the absence of natural fractures or adequate connectivity, artificial fractures are created in the reservoir using hydraulic fracturing. Multiple fractures are preferred because of themore » large size necessary when using only a single fracture. Although the basic idea is rather simple, hydraulic fracturing is a complex process involving interactions of high pressure fluid injections with a stressed hot rock mass, mechanical interaction of induced fractures with existing natural fractures, and the spatial and temporal variations of in-situ stress. As a result, it is necessary to develop tools that can be used to study these interactions as an integral part of a comprehensive approach to geothermal reservoir development, particularly enhanced geothermal systems. In response to this need we have developed advanced poro-thermo-chemo-mechanical fracture models for rock fracture research in support of EGS design. The fracture propagation models are based on a regular displacement discontinuity formulation. The fracture propagation studies include modeling interaction of induced fractures. In addition to the fracture propagation studies, two-dimensional solution algorithms have been developed and used to estimate the impact of pro-thermo-chemical processes on fracture permeability and reservoir pressure. Fracture permeability variation is studied using a coupled thermo-chemical model with quartz reaction kinetics. The model is applied to study quartz precipitation/dissolution, as well as the variation in fracture aperture and pressure. Also, a three-dimensional model of injection/extraction has been developed to consider the impact poro- and thermoelastic stresses on fracture slip and injection pressure. These investigations shed light on the processes involved in the observed phenomenon of injection pressure variation (e.g., in Coso), and allow the assessment of the potential of thermal and chemical stimulation strategies.« less

  2. [Clinical characteristics and surgical management of Eyres type V coracoid fracture combined with superior shoulder suspensory complex injury].

    PubMed

    Liu, Hongzhi; Qiu, Changmao; Liu, Zhaojie; Zhang, Yinguang; Tian, Wei; Jia, Jian

    2014-12-01

    To investigate the clinical characteristics of Eyres type V coracoid fracture combined with superior shoulder suspensory complex (SSSC) injuries, and the effectiveness of open reduction and fixation. Between March 2004 and July 2012, 13 patients with Eyres type V coracoid fracture and SSSC injuries were treated. There were 10 males and 3 females with an average age of 41 years (range, 23-59 years). Injury was caused by falling from height in 4 cases, by traffic accident in 6 cases, and by impact of the heavy weight in 3 cases. The interval from injury to operation was 3-10 days (mean, 5.2 days). SSSC injuries included 9 cases of acromioclavicular joint dislocation, 5 cases of clavicular fractures, and 4 cases of acromion fractures. The coracoid fractures were fixed with cannulated screws; the acromioclavicular joint dislocations were fixed with hook plate (6 cases) or Kirschner wires (2 case) except 1 untreated case; the clavicular fractures were fixed with anatomical locking plate (3 cases) and hook plate (2 cases); the acromion fractures were fixed with cannulated screws (1 case), Kirschner wires (2 cases), or both of them (1 case). The mean operation time was 158.0 minutes (range, 100-270 minutes), and the mean intraoperative blood loss was 207.7 mL (range, 150-300 mL). The other patients obtained primary healing of incision except 1 patient who had inflammation around incision, which was cured after change dressing. All patients were followed up for 22.6 months on average (range, 17-35 months). All fractures achieved union at a mean time of 3.6 months (range, 2-6 months). No nerve injury and implant fixation failure complications were observed. At last follow-up, the Constant score and the disability of the arm, shoulder, and hand (DASH) score had a significant improvement when compared with scores at pre-operation (P < 0.05). The shoulder range of motion in flexion, abduction, and external rotation at last follow-up were significantly higher than those at pre-operation (P < 0.05). Eyres type V coracoid fracture associated with SSSC injuries usually results in the instability of the shoulder. With individual surgical treatment, the satisfactory function and good effectiveness can be obtained.

  3. Spectroscopic Biomarkers for Monitoring Wound Healing and Infection in Combat Wounds

    DTIC Science & Technology

    2011-10-01

    thrombotic, and fat embolism , and compartment syndrome. In the treatment of such complex traumatic injuries, improved assessment of global and...injuries include traumatic amputations, open fractures , crush injuries, burns, acute vascular disruption, blastwave-associated pressure injuries, air...injury, it develops in only 20% and 11% of patients. Rates of HO formation exceed 50% only in the setting of femoral shaft fractures with

  4. Prospective analysis of magnetic resonance imaging accuracy in diagnosing traumatic injuries of the posterior ligamentous complex of the thoracolumbar spine.

    PubMed

    Pizones, Javier; Sánchez-Mariscal, Felisa; Zúñiga, Lorenzo; Álvarez, Patricia; Izquierdo, Enrique

    2013-04-20

    Prospective cohort study. To study magnetic resonance imaging (MRI) accuracy in diagnosing posterior ligamentous complex (PLC) damage, when applying the new dichotomic instability criteria in a prospective cohort of patients with vertebral fracture. Recent studies dispute MRI accuracy to diagnose PLC injuries. They analyze the complex based on 3 categories (intact/indeterminate/rupture), including the indeterminate in the ruptured group (measurement bias) in the accuracy analysis. Moreover, fractures with conservative treatment (selection bias) are not included. Both facts reduce the specificity. A recent study has proposed new criteria where posterior instability is determined with supraspinous ligament (SSL) rupture. Prospective study of patients with acute thoracolumbar fracture, using radiography and MRI (FS-T2-w/short-tau inversion-recovery sequences). 1. The integrity (ruptured/unruptured) of each isolated component of the PLC (facet capsules, interspinous ligament, SSL, and ligamentum flavum) was assessed via MRI and surgical findings. 2. PLC integrity as a whole was assessed, adopting the new dichotomic stability criteria from previous studies. In the MR images, PLC is considered ruptured when the SSL is found discontinued, and intact when not (this excludes the "indeterminate" category). In surgically treated fractures, PLC stability as a whole was assessed dynamically (ruptured/unruptured). In conservative fractures, PLC stability was assessed according to change in vertebral kyphosis measured with the local kyphotic angle at 2-year follow-up (ruptured if difference is > 5°/unruptured if difference is < 5°).3. Comparative analysis among findings provided MRI accuracy in diagnosing PLC damage. Fifty-eight vertebral fractures were studied (38 surgical, 20 conservative), of which 50% were in males; average age, 40.4 years. MRI sensitivity for injury diagnosis of each isolated PLC component varied between 92.3% (interspinous ligament) and 100% (ligamentum flavum). Specificity varied between 52% (facet capsules) and 100% (SSL). PLC integrity sensitivity and specificity as a whole were 91% and 100%, respectively. Adopting the new stability criteria, MRI accuracy in PLC injury diagnosis increases. Specificity is increased (true positives) both in isolated component analysis and PLC as a whole.

  5. Mechanical and hydraulic properties of rocks related to induced seismicity

    USGS Publications Warehouse

    Witherspoon, P.A.; Gale, J.E.

    1977-01-01

    Witherspoon, P.A. and Gale, J.E., 1977. Mechanical and hydraulic properties of rocks related to induced seismicity. Eng. Geol., 11(1): 23-55. The mechanical and hydraulic properties of fractured rocks are considered with regard to the role they play in induced seismicity. In many cases, the mechanical properties of fractures determine the stability of a rock mass. The problems of sampling and testing these rock discontinuities and interpreting their non-linear behavior are reviewed. Stick slip has been proposed as the failure mechanism in earthquake events. Because of the complex interactions that are inherent in the mechanical behavior of fractured rocks, there seems to be no simple way to combine the deformation characteristics of several sets of fractures when there are significant perturbations of existing conditions. Thus, the more important fractures must be treated as individual components in the rock mass. In considering the hydraulic properties, it has been customary to treat a fracture as a parallel-plate conduit and a number of mathematical models of fracture systems have adopted this approach. Non-steady flow in fractured systems has usually been based on a two-porosity model, which assumes the primary (intergranular) porosity contributes only to storage and the secondary (fracture) porosity contributes only to the overall conductivity. Using such a model, it has been found that the time required to achieve quasi-steady state flow in a fractured reservoir is one or two orders of magnitude greater than it is in a homogeneous system. In essentially all of this work, the assumption has generally been made that the fractures are rigid. However, it is clear from a review of the mechanical and hydraulic properties that not only are fractures easily deformed but they constitute the main flow paths in many rock masses. This means that one must consider the interaction of mechanical and hydraulic effects. A considerable amount of laboratory and field data is now available that clearly demonstrates this stress-flow behavior. Two approaches have been used in attempting to numerically model such behavior: (1) continuum models, and (2) discrete models. The continuum approach only needs information as to average values of fracture spacing and material properties. But because of the inherent complexity of fractured rock masses and the corresponding decrease in symmetry, it is difficult to develop an equivalent continuum that will simulate the behavior of the entire system. The discrete approach, on the other hand, requires details of the fracture geometry and material properties of both fractures and rock matrix. The difficulty in obtaining such information has been considered a serious limitation of discrete models, but improved borehole techniques can enable one to obtain the necessary data, at least in shallow systems. The possibility of extending these methods to deeper fracture systems needs more investigation. Such data must be considered when deciding whether to use a continuum or discrete model to represent the interaction of rock and fluid forces in a fractured rock system, especially with regard to the problem of induced seismicity. When one is attempting to alter the pressure distribution in a fault zone by injection or withdrawal of fluids, the extent to which this can be achieved will be controlled in large measure by the behavior of the fractures that communicate with the borehole. Since this is essentially a point phenomenon, i.e., the changes will propagate from a relatively small region around the borehole, the use of a discrete model would appear to be preferable. ?? 1977.

  6. Fractured-aquifer hydrogeology from geophysical logs; the passaic formation, New Jersey

    USGS Publications Warehouse

    Morin, R.H.; Carleton, G.B.; Poirier, S.

    1997-01-01

    The Passaic Formation consists of gradational sequences of mudstone, siltstone, and sandstone, and is a principal aquifer in central New Jersey. Ground-water flow is primarily controlled by fractures interspersed throughout these sedimentary rocks and characterizing these fractures in terms of type, orientation, spatial distribution, frequency, and transmissivity is fundamental towards understanding local fluid-transport processes. To obtain this information, a comprehensive suite of geophysical logs was collected in 10 wells roughly 46 m in depth and located within a .05 km2 area in Hopewell Township, New Jersey. A seemingly complex, heterogeneous network of fractures identified with an acoustic televiewer was statistically reduced to two principal subsets corresponding to two distinct fracture types: (1) bedding-plane partings and (2) high-angle fractures. Bedding-plane partings are the most numerous and have an average strike of N84??W and dip of 20??N. The high-angle fractures are oriented subparallel to these features, with an average strike of N79??E and dip of 71??S, making the two fracture types roughly orthogonal. Their intersections form linear features that also retain this approximately east-west strike. Inspection of fluid temperature and conductance logs in conjunction with flowmeter measurements obtained during pumping allows the transmissive fractures to be distinguished from the general fracture population. These results show that, within the resolution capabilities of the logging tools, approximately 51 (or 18 percent) of the 280 total fractures are water producing. The bedding-plane partings exhibit transmissivities that average roughly 5 m2/day and that generally diminish in magnitude and frequency with depth. The high-angle fractures have average transmissivities that are about half those of the bedding-plane partings and show no apparent dependence upon depth. The geophysical logging results allow us to infer a distinct hydrogeologic structure within this aquifer that is defined by fracture type and orientation. Fluid flow near the surface is controlled primarily by the highly transmissive, subhorizontal bedding-plane partings. As depth increases, the high-angle fractures apparently become more dominant hydrologically.The Passaic Formation consists of gradational sequences of mudstone, siltstone, and sandstone, and is a principal aquifer in central New Jersey. Ground-water flow is primarily controlled by fractures interspersed throughout these sedimentary rocks and characterizing these fractures in terms of type, orientation, spatial distribution, frequency, and transmissivity is fundamental towards understanding local fluid-transport processes. To obtain this information, a comprehensive suite of geophysical logs was collected in 10 wells roughly 46 m in depth and located within a .05 km2 area in Hopewell Township, New Jersey. A seemingly complex, heterogeneous network of fractures identified with an acoustic televiewer was statistically reduced to two principal subsets corresponding to two distinct fracture types: (1) bedding-plane partings and (2) high-angle fractures. Bedding-plane partings are the most numerous and have an average strike of N84?? W and dip of 20?? N. The high-angle fractures are oriented subparallel to these features, with an average strike of N79?? E and dip of 71?? S, making the two fracture types roughly orthogonal. Their intersections form linear features that also retain this approximately east-west strike. Inspection of fluid temperature and conductance logs in conjunction with flowmeter measurements obtained during pumping allows the transmissive fractures to be distinguished from the general fracture population. These results show that, within the resolution capabilities of the logging tools, approximately 51 (or 18 percent) of the 280 total fractures are water producing. The bedding-plane partings exhibit transmissivities that average roughly 5 m2/day and that generally dimi

  7. Diagnostic tools in maxillofacial fractures: Is there really a need of three-dimensional computed tomography?

    PubMed Central

    Shah, Sheerin; Uppal, Sanjeev K.; Mittal, Rajinder K.; Garg, Ramneesh; Saggar, Kavita; Dhawan, Rishi

    2016-01-01

    Introduction: Because of its functional and cosmetic importance, facial injuries, especially bony fractures are clinically very significant. Missed and maltreated fractures might result in malocclusion and disfigurement of the face, thus making accurate diagnosis of the fracture very essential. In earlier times, conventional radiography along with clinical examination played a major role in diagnosis of maxillofacial fractures. However, it was noted that the overlapping nature of bones and the inability to visualise soft tissue swelling and fracture displacement, especially in face, makes radiography less reliable and useful. Computed tomography (CT), also called as X-ray computed radiography, has helped in solving this problem. This clinical study is to compare three-dimensional (3D) CT reconstruction with conventional radiography in evaluating the maxillofacial fractures preoperatively and effecting the surgical management, accordingly. Materials and Methods: Fifty patients, with suspected maxillofacial fractures on clinical examination, were subjected to conventional radiography and CT face with 3D reconstruction. The number and site of fractures in zygoma, maxilla, mandible and nose, detected by both the methods, were enumerated and compared. The final bearing of these additional fractures, on the management protocol, was analysed. Results: CT proved superior to conventional radiography in diagnosing additional number of fractures in zygoma, maxilla, mandible (subcondylar) and nasal bone. Coronal and axial images were found to be significantly more diagnostic in fracture sites such as zygomaticomaxillary complex, orbital floor, arch, lateral maxillary wall and anterior maxillary wall. Conclusion: 3D images gave an inside out picture of the actual sites of fractures. It acted as mind's eye for pre-operative planning and intra-operative execution of surgery. Better surgical treatment could be given to 33% of the cases because of better diagnostic ability of CT. PMID:27833286

  8. Diagnostic tools in maxillofacial fractures: Is there really a need of three-dimensional computed tomography?

    PubMed

    Shah, Sheerin; Uppal, Sanjeev K; Mittal, Rajinder K; Garg, Ramneesh; Saggar, Kavita; Dhawan, Rishi

    2016-01-01

    Because of its functional and cosmetic importance, facial injuries, especially bony fractures are clinically very significant. Missed and maltreated fractures might result in malocclusion and disfigurement of the face, thus making accurate diagnosis of the fracture very essential. In earlier times, conventional radiography along with clinical examination played a major role in diagnosis of maxillofacial fractures. However, it was noted that the overlapping nature of bones and the inability to visualise soft tissue swelling and fracture displacement, especially in face, makes radiography less reliable and useful. Computed tomography (CT), also called as X-ray computed radiography, has helped in solving this problem. This clinical study is to compare three-dimensional (3D) CT reconstruction with conventional radiography in evaluating the maxillofacial fractures preoperatively and effecting the surgical management, accordingly. Fifty patients, with suspected maxillofacial fractures on clinical examination, were subjected to conventional radiography and CT face with 3D reconstruction. The number and site of fractures in zygoma, maxilla, mandible and nose, detected by both the methods, were enumerated and compared. The final bearing of these additional fractures, on the management protocol, was analysed. CT proved superior to conventional radiography in diagnosing additional number of fractures in zygoma, maxilla, mandible (subcondylar) and nasal bone. Coronal and axial images were found to be significantly more diagnostic in fracture sites such as zygomaticomaxillary complex, orbital floor, arch, lateral maxillary wall and anterior maxillary wall. 3D images gave an inside out picture of the actual sites of fractures. It acted as mind's eye for pre-operative planning and intra-operative execution of surgery. Better surgical treatment could be given to 33% of the cases because of better diagnostic ability of CT.

  9. A study of sports-related orbital fractures in Singapore.

    PubMed

    Lock, Jing Zhan; Hegde, Raghuraj; Young, Stephanie; Lim, Thiam Chye; Amrith, Shantha; Sundar, Gangadhara

    2017-10-01

    With an increased popularity of sport and active living worldwide, our study aims to explore the incidence and features of sports-related orbital fractures in Singapore. 1421 computer tomography (CT) imaging scans of the face and orbits done at the National University Hospital over a 24-month period from January 2013 and December 2014 were reviewed retrospectively for orbital fractures. We identified 483 orbital fractures of which sports injury was the fourth most common etiology (n = 65; 13.5%) after road traffic accident (n = 131; 27.1%), geriatric fall (n = 81; 16.8%) and workplace injury (n = 67; 13.9%). The three most common sport in orbital fractures were soccer (n = 20; 30.8%), bicycling (n = 11; 16.9%) and jogging (n = 8; 12.3%). The three most common fracture patterns were zygomatico-maxillary complex fractures (n = 24; 36.9%), isolated one wall blowout fractures (n = 19; 29.2%) and naso-orbito-ethmoid fractures (n = 7; 10.8%). Sports-related orbital fractures were associated with a low mean age of patients (45.9 years, range, 14-79 years), a higher proportion of males (n = 58; 89.2%) than that from geriatric falls (n = 37, 45.6%) (P < 0.01), a higher likelihood of unilaterality (n = 62; 95.4%) than that from traffic accidents (n = 99; 75.6%) (P < 0.01) and a lower likelihood of pan-facial involvement (n = 4; 6.15%) than that from traffic accident (n = 60; 45.8%) (P < 0.01). Sports-related orbital fractures are the fourth most common cause of orbital fractures. Though commonly seen in young male adults, in view of the aging population and people exercising more regularly, education of safety measures among sports users is paramount to preventing sports-related orbital fractures.

  10. Facial Fracture Management in Northwest Nigeria

    PubMed Central

    Taiwo, Abdurrazaq Olanrewaju; Soyele, Olujide Oladele; Godwin, Ndubuizi Ugochukwu; Ibikunle, Adebayo Aremu

    2013-01-01

    Background: Facial fracture is gradually become a public health problem in our community due to the attendant morbidity and mortality. Hence, the aim of this study was to determine the pattern of facial fracture in Dental and Maxillofacial Surgery Department of Usmanu Danfodiyo University Teaching Hospital. This cross-sectional study was undertaken to provide information regarding gender, age, etiology, and diagnosis of patients with maxillofacial fractures. Materials and Methods: A 1-year review of patients diagnosed and treated for facial fractures in Usmanu Danfodiyo University Teaching Hospital between January 2011 and December 2011. The diagnosis was based on radiographic data and clinical examination. The main analysis outcome measures were etiology, age, gender, site, and treatment. Data were organized and presented by means of descriptive statistics and Pearson's Chi-square test. The level of significance adopted was 5%. Results: A total of 40 patients were treated in this period. Over 95% were male, 81% were caused by road traffic crash (RTC) and 86.4% were in the 21-30 years group. Most patients (52%) had mandibular fractures, and the most common site was the body. Most patients with midfacial fractures had fractures of the zygomaticomaxillary region (36%), while fractures of the parasymphyseal region were more common in the mandible 156 (31%). The most common treatment for jaw fractures was mandibulomaxillary fixation (MMF). Stable zygomatic complex fractures were reduced (elevated) intraorally, and unstable ones were supported by antral packs. Conclusions: This study highlights facial fractures secondary to RTC as a serious public health problem in our environment. Preventive strategies remain the cheapest way to reduce direct and indirect costs of the sequelae of RTC. It also bring to the fore the necessity to shift to open reduction and internal fixation (ORIF) of fractures. PMID:24741422

  11. Stimulating Fracture Healing in Ischemic Environments: Does Oxygen Direct Stem Cell Fate during Fracture Healing?

    PubMed Central

    Miclau, Katherine R.; Brazina, Sloane A.; Bahney, Chelsea S.; Hankenson, Kurt D.; Hunt, Thomas K.; Marcucio, Ralph S.; Miclau, Theodore

    2017-01-01

    Bone fractures represent an enormous societal and economic burden as one of the most prevalent causes of disability worldwide. Each year, nearly 15 million people are affected by fractures in the United States alone. Data indicate that the blood supply is critical for fracture healing; as data indicate that concomitant bone and vascular injury are major risk factors for non-union. However, the various role(s) that the vasculature plays remains speculative. Fracture stabilization dictates stem cell fate choices during repair. In stabilized fractures stem cells differentiate directly into osteoblasts and heal the injury by intramembranous ossification. In contrast, in non-stable fractures stem cells differentiate into chondrocytes and the bone heals through endochondral ossification, where a cartilage template transforms into bone as the chondrocytes transform into osteoblasts. One suggested role of the vasculature has been to participate in the stem cell fate decisions due to delivery of oxygen. In stable fractures, the blood vessels are thought to remain intact and promote osteogenesis, while in non-stable fractures, continual disruption of the vasculature creates hypoxia that favors formation of cartilage, which is avascular. However, recent data suggests that non-stable fractures are more vascularized than stable fractures, that oxygen does not appear associated with differentiation of stem cells into chondrocytes and osteoblasts, that cartilage is not hypoxic, and that oxygen, not sustained hypoxia, is required for angiogenesis. These unexpected results, which contrast other published studies, are indicative of the need to better understand the complex, spatio-temporal regulation of vascularization and oxygenation in fracture healing. This work has also revealed that oxygen, along with the promotion of angiogenesis, may be novel adjuvants that can stimulate healing in select patient populations. PMID:28523266

  12. Role of Ankle Arthroscopy in Management of Acute Ankle Fracture.

    PubMed

    Chan, Kwok Bill; Lui, Tun Hing

    2016-11-01

    To report the operative findings of ankle arthroscopy during open reduction and internal fixation of acute ankle fractures. This was a retrospective review of 254 consecutive patients with acute ankle fractures who were treated with open reduction and internal fixation of the fractures, and ankle arthroscopy was performed at the same time. The accuracy of fracture reduction, the presence of syndesmosis disruption and its reduction, and the presence of ligamentous injuries and osteochondral lesions were documented. Second-look ankle arthroscopy was performed during syndesmosis screw removal 6 weeks after the key operation. There were 6 patients with Weber A, 177 patients with Weber B, 51 patients with Weber C, and 20 patients with isolated medial malleolar fractures. Syndesmosis disruption was present in 0% of patients with Weber A fracture, 52% of patients with Weber B fracture, 92% of patients with Weber C fracture, and 20% of the patients with isolated medial malleolar fracture. Three patients with Weber B and one patient with Weber C fracture have occult syndesmosis instability after screw removal. Osteochondral lesion was present in no patient with Weber A fracture, 26% of the Weber B cases, 24% of the Weber C cases, and 20% of isolated medial malleolar fracture cases. The association between the presence of deep deltoid ligament tear and syndesmosis disruption (warranting syndesmosis screw fixation) in Weber B cases was statistically significant but not in Weber C cases. There was no statistically significant association between the presence of posterior malleolar fracture and syndesmosis instability that warrant screw fixation. Ankle arthroscopy is a useful adjuvant tool to understand the severity and complexity of acute ankle fracture. Direct arthroscopic visualization ensures detection and evaluation of intra-articular fractures, syndesmosis disruption, and associated osteochondral lesions and ligamentous injuries. Level IV, case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. Water Pressure Effects on Strength and Deformability of Fractured Rocks Under Low Confining Pressures

    NASA Astrophysics Data System (ADS)

    Noorian Bidgoli, Majid; Jing, Lanru

    2015-05-01

    The effect of groundwater on strength and deformation behavior of fractured crystalline rocks is one of the important issues for design, performance and safety assessments of surface and subsurface rock engineering problems. However, practical difficulties make the direct in situ and laboratory measurements of these properties of fractured rocks impossible at present, since effects of complex fracture system hidden inside the rock masses cannot be accurately estimated. Therefore, numerical modeling needs to be applied. The overall objective of this paper is to deepen our understanding on the validity of the effective stress concept, and to evaluate the effects of water pressure on strength and deformation parameters. The approach adopted uses discrete element methods to simulate the coupled stress-deformation-flow processes in a fractured rock mass with model dimensions at a representative elementary volume (REV) size and realistic representation of fracture system geometry. The obtained numerical results demonstrate that water pressure has significant influence on the strength, but with minor effects on elastic deformation parameters, compared with significant influence by the lateral confining pressure. Also, the classical effective stress concept to fractured rock can be quite different with that applied in soil mechanics. Therefore, one should be cautious when applying the classical effective stress concept to fractured rock media.

  14. Pelvic trauma with displaced sacral fractures: functional outcome at one year.

    PubMed

    Tötterman, Anna; Glott, Thomas; Søberg, Helene Lundgaard; Madsen, Jan Erik; Røise, Olav

    2007-06-01

    A prospective single-cohort study of 31 patients surgically treated for pelvic injuries with displaced sacral fractures. To describe the medium term functional outcome in unstable sacral fractures. Displaced sacral fractures pose a special challenge in orthopedic surgery due to the high rate of associated injuries. Little information is available on the medium-term functional outcome of patients with injuries which include unstable sacral fractures. We examined 31 patients with displaced sacral fractures having 10 mm or more displacement, 1 year (mean, 1.4 years; range, 1.0-2.5 years) after injury. Data from a previous study were supplemented with functional outcome measures (work status, independence in ADL, and SF-36). An association between outcome and tested variables was sought. Fifteen months after injury, 65% of the patients had regained their independence in functions pertaining to daily activities; 33% had returned to work. All dimensions of perceived health were affected. Polytrauma and impairments relative to voiding and sexual function had a detrimental effect on outcome. Fracture characteristics were not predictive of poor outcome. Although the majority of patients achieved independent living, medium-term follow-up indicated significant residual disability. The complex nature of these fractures and the associated injuries should be considered in the rehabilitation of these patients.

  15. Multi-Region Boundary Element Analysis for Coupled Thermal-Fracturing Processes in Geomaterials

    NASA Astrophysics Data System (ADS)

    Shen, Baotang; Kim, Hyung-Mok; Park, Eui-Seob; Kim, Taek-Kon; Wuttke, Manfred W.; Rinne, Mikael; Backers, Tobias; Stephansson, Ove

    2013-01-01

    This paper describes a boundary element code development on coupled thermal-mechanical processes of rock fracture propagation. The code development was based on the fracture mechanics code FRACOD that has previously been developed by Shen and Stephansson (Int J Eng Fracture Mech 47:177-189, 1993) and FRACOM (A fracture propagation code—FRACOD, User's manual. FRACOM Ltd. 2002) and simulates complex fracture propagation in rocks governed by both tensile and shear mechanisms. For the coupled thermal-fracturing analysis, an indirect boundary element method, namely the fictitious heat source method, was implemented in FRACOD to simulate the temperature change and thermal stresses in rocks. This indirect method is particularly suitable for the thermal-fracturing coupling in FRACOD where the displacement discontinuity method is used for mechanical simulation. The coupled code was also extended to simulate multiple region problems in which rock mass, concrete linings and insulation layers with different thermal and mechanical properties were present. Both verification and application cases were presented where a point heat source in a 2D infinite medium and a pilot LNG underground cavern were solved and studied using the coupled code. Good agreement was observed between the simulation results, analytical solutions and in situ measurements which validates an applicability of the developed coupled code.

  16. Determination of the effect of formation water on fracture-fluid cleanup

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-03-01

    Understanding hydraulic-fracture cleanup is essential for improving well stimulation. Residual gel damages fracture conductivity, shortens effective fracture half-length, and limits well productivity. The drive to develop fluids, additives, and procedures that minimize this damage continues to be a dominant theme in fracture-fluid-development programs. Fracture cleanup is a complex problem, and many parameters (e.g., fluid system, job design, flowback procedure, and reservoir conditions) can influence polymer and fluid recovery efficiencies. Often, specific products and methods that work well in one reservoir have little effect in another. Systematic analysis of fluid and polymer returns after a treatment is completed is the onlymore » way to quantify fracture cleanup. This is referred to as flowback analysis. This paper discusses a flowback-analysis field study on large hydraulic-fracturing treatments in the Taylor zone of the Cotton Valley formation in east Texas. This is a low-permeability (approximately 0.01 md) tight gas formation. It is a heterogeneous zone with layers of productive sandstone interspersed with relatively impermeable layers of shale. A typical well in this field initially produces approximately 0.75 to 1.3 MMcf/D gas and 35 to 40 bbl of water/MMcf of gas. The returns from 10 wells in this field were analyzed thoroughly.« less

  17. Structural controls on anomalous transport in fractured porous rock

    NASA Astrophysics Data System (ADS)

    Edery, Yaniv; Geiger, Sebastian; Berkowitz, Brian

    2016-07-01

    Anomalous transport is ubiquitous in a wide range of disordered systems, notably in fractured porous formations. We quantitatively identify the structural controls on anomalous tracer transport in a model of a real fractured geological formation that was mapped in an outcrop. The transport, determined by a continuum scale mathematical model, is characterized by breakthrough curves (BTCs) that document anomalous (or "non-Fickian") transport, which is accounted for by a power law distribution of local transition times ψ>(t>) within the framework of a continuous time random walk (CTRW). We show that the determination of ψ>(t>) is related to fractures aligned approximately with the macroscopic direction of flow. We establish the dominant role of fracture alignment and assess the statistics of these fractures by determining a concentration-visitation weighted residence time histogram. We then convert the histogram to a probability density function (pdf) that coincides with the CTRW ψ>(t>) and hence anomalous transport. We show that the permeability of the geological formation hosting the fracture network has a limited effect on the anomalous nature of the transport; rather, it is the fractures transverse to the flow direction that play the major role in forming the long BTC tail associated with anomalous transport. This is a remarkable result, given the complexity of the flow field statistics as captured by concentration transitions.

  18. The effect of HIV on early wound healing in open fractures treated with internal and external fixation.

    PubMed

    Aird, J; Noor, S; Lavy, C; Rollinson, P

    2011-05-01

    There are 33 million people worldwide currently infected with human immunodeficiency virus (HIV). This complex disease affects many of the processes involved in wound and fracture healing, and there is little evidence available to guide the management of open fractures in these patients. Fears of acute and delayed infection often inhibit the use of fixation, which may be the most effective way of achieving union. This study compared fixation of open fractures in HIV-positive and -negative patients in South Africa, a country with very high rates of both HIV and high-energy trauma. A total of 133 patients (33 HIV-positive) with 135 open fractures fulfilled the inclusion criteria. This cohort is three times larger than in any similar previously published study. The results suggest that HIV is not a contraindication to internal or external fixation of open fractures in this population, as HIV is not a significant risk factor for acute wound/implant infection. However, subgroup analysis of grade I open fractures in patients with advanced HIV and a low CD4 count (< 350) showed an increased risk of infection; we suggest that grade I open fractures in patients with advanced HIV should be treated by early debridement followed by fixation at an appropriate time.

  19. A Preoperative Planning Tool: Aggregate Anterior Approach to the Humerus With Quantitative Comparisons.

    PubMed

    Phelps, Kevin D; Harmer, Luke S; Crickard, Colin V; Hamid, Nady; Sample, Katherine M; Andrews, Erica B; Seymour, Rachel B; Hsu, Joseph R

    2018-06-01

    Extensile approaches to the humerus are often needed when treating complex proximal or distal fractures that have extension into the humeral shaft or in those fractures that occur around implants. The 2 most commonly used approaches for more complex fractures include the modified lateral paratricipital approach and the deltopectoral approach with distal anterior extension. Although the former is well described and quantified, the latter is often associated with variable nomenclature with technical descriptions that can be confusing. Furthermore, a method to expose the entire humerus through an anterior extensile approach has not been described. Here, we illustrate and quantify a technique for connecting anterior humeral approaches in a stepwise fashion to form an aggregate anterior approach (AAA). We also describe a method for further distal extension to expose 100% of the length of the humerus and compare this approach with both the AAA and the lateral paratricipital in terms of access to critical bony landmarks, as well as the length and area of bone exposed.

  20. Experimental and numerical study of hydraulic fracture geometry in shale formations with complex geologic conditions

    NASA Astrophysics Data System (ADS)

    Ma, Xinfang; Zhou, Tong; Zou, Yushi

    2017-05-01

    Strike-slip fault geostress and dipping laminated structures in Lujiaping shale formation typically result in difficultly predicting hydraulic fracture (HF) geometries. In this study, a novel 3D fracture propagation model based on discrete element method (DEM) is established. A series of simulations is performed to illustrate the influence of vertical stress difference (△σv = σv-σh), fluid viscosity, and injection rate, on HF growth geometry in the dipping layered formation. Results reveal that the fracturing fluid can easily infiltrate the dipping bedding plane (BP) interfaces with low net pressure for △σv = 1 MPa. HF height growth is also restricted. With increased △σv, fracture propagation in the vertical direction is enhanced, and a fracture network is formed by VF and partially opened dipping BPs. However, it is likely to create simple VF for △σv = 20 MPa. Appropriately increasing fracturing fluid viscosity and injection rate is conductive to weakening the containment effect of BPs on HF growth by increasing the fluid net pressure. However, no indication is found on whether a higher fracturing fluid viscosity is better. Higher viscosity can reduce the activation of BPs, so a stimulated reservoir volume is not necessarily increased. All these results can serve as theoretical guidance for the optimization of fracturing treatments in Lujiaping shale formation.

  1. The Photodynamic Bone Stabilization System: a minimally invasive, percutaneous intramedullary polymeric osteosynthesis for simple and complex long bone fractures.

    PubMed

    Vegt, Paul; Muir, Jeffrey M; Block, Jon E

    2014-01-01

    The treatment of osteoporotic long bone fractures is difficult due to diminished bone density and compromised biomechanical integrity. The majority of osteoporotic long bone fractures occur in the metaphyseal region, which poses additional problems for surgical repair due to increased intramedullary volume. Treatment with internal fixation using intramedullary nails or plating is associated with poor clinical outcomes in this patient population. Subsequent fractures and complications such as screw pull-out necessitate additional interventions, prolonging recovery and increasing health care costs. The Photodynamic Bone Stabilization System (PBSS) is a minimally invasive surgical technique that allows clinicians to repair bone fractures using a light-curable polymer contained within an inflatable balloon catheter, offering a new treatment option for osteoporotic long bone fractures. The unique polymer compound and catheter application provides a customizable solution for long bone fractures that produces internal stability while maintaining bone length, rotational alignment, and postsurgical mobility. The PBSS has been utilized in a case series of 41 fractures in 33 patients suffering osteoporotic long bone fractures. The initial results indicate that the use of the light-cured polymeric rod for this patient population provides excellent fixation and stability in compromised bone, with a superior complication profile. This paper describes the clinical uses, procedural details, indications for use, and the initial clinical findings of the PBSS.

  2. The Photodynamic Bone Stabilization System: a minimally invasive, percutaneous intramedullary polymeric osteosynthesis for simple and complex long bone fractures

    PubMed Central

    Vegt, Paul; Muir, Jeffrey M; Block, Jon E

    2014-01-01

    The treatment of osteoporotic long bone fractures is difficult due to diminished bone density and compromised biomechanical integrity. The majority of osteoporotic long bone fractures occur in the metaphyseal region, which poses additional problems for surgical repair due to increased intramedullary volume. Treatment with internal fixation using intramedullary nails or plating is associated with poor clinical outcomes in this patient population. Subsequent fractures and complications such as screw pull-out necessitate additional interventions, prolonging recovery and increasing health care costs. The Photodynamic Bone Stabilization System (PBSS) is a minimally invasive surgical technique that allows clinicians to repair bone fractures using a light-curable polymer contained within an inflatable balloon catheter, offering a new treatment option for osteoporotic long bone fractures. The unique polymer compound and catheter application provides a customizable solution for long bone fractures that produces internal stability while maintaining bone length, rotational alignment, and postsurgical mobility. The PBSS has been utilized in a case series of 41 fractures in 33 patients suffering osteoporotic long bone fractures. The initial results indicate that the use of the light-cured polymeric rod for this patient population provides excellent fixation and stability in compromised bone, with a superior complication profile. This paper describes the clinical uses, procedural details, indications for use, and the initial clinical findings of the PBSS. PMID:25540600

  3. Differential Efficacy of Ketamine in the Acute versus Chronic Stages of Complex Regional Pain Syndrome in Mice

    PubMed Central

    Tajerian, Maral; Leu, David; Yang, Phillip; Huang, Ting Ting; Kingery, Wade S; Clark, J David

    2015-01-01

    Background Complex regional pain syndrome (CRPS) is a painful, disabling and often chronic condition, where many patients transition from an acute phase with prominent peripheral neurogenic inflammation to a chronic phase with evident central nervous system (CNS) changes. Ketamine is a centrally-acting agent believed to work through blockade of N-methyl-D-aspartate (NMDA) receptors and is being increasingly used for the treatment of refractory CRPS, although the basis for the drug’s effects and efficacy at different stages of the syndrome remain unclear. Methods We used a mouse model of CRPS (n=8–12/group) involving tibia fracture/cast immobilization to test the efficacy of ketamine (2 mg/kg/day; 7 days) or vehicle infusion during acute (3weeks [3w] post-fracture) and chronic (7w post-fracture) stages. Results Acute phase fracture mice displayed elevated limb temperature, edema and nociceptive sensitization that were not reduced by ketamine. Fracture mice treated with ketamine during the chronic phase showed reduced nociceptive sensitization that persisted beyond completion of the infusion. During this chronic phase, ketamine also reduced latent nociceptive sensitization and improved motor function at 18 weeks post-fracture. No side effects of the infusions were identified. These behavioral changes were associated with altered spinal astrocyte activation and expression of pain-related proteins including NMDA receptor 2b (NR2b), Ca2+/calmodulin-dependent protein kinase ii (CaMK2), and brain-derived neurotrophic factor (BNDF). Conclusions Collectively, these results demonstrate that ketamine is efficacious in the chronic, but not acute stages of CRPS, suggesting that the centrally-acting drug is relatively ineffective in early CRPS when peripheral mechanisms are more critical for supporting nociceptive sensitization. PMID:26492479

  4. Evaluating uncertainty in predicting spatially variable representative elementary scales in fractured aquifers, with application to Turkey Creek Basin, Colorado

    USGS Publications Warehouse

    Wellman, Tristan P.; Poeter, Eileen P.

    2006-01-01

    Computational limitations and sparse field data often mandate use of continuum representation for modeling hydrologic processes in large‐scale fractured aquifers. Selecting appropriate element size is of primary importance because continuum approximation is not valid for all scales. The traditional approach is to select elements by identifying a single representative elementary scale (RES) for the region of interest. Recent advances indicate RES may be spatially variable, prompting unanswered questions regarding the ability of sparse data to spatially resolve continuum equivalents in fractured aquifers. We address this uncertainty of estimating RES using two techniques. In one technique we employ data‐conditioned realizations generated by sequential Gaussian simulation. For the other we develop a new approach using conditioned random walks and nonparametric bootstrapping (CRWN). We evaluate the effectiveness of each method under three fracture densities, three data sets, and two groups of RES analysis parameters. In sum, 18 separate RES analyses are evaluated, which indicate RES magnitudes may be reasonably bounded using uncertainty analysis, even for limited data sets and complex fracture structure. In addition, we conduct a field study to estimate RES magnitudes and resulting uncertainty for Turkey Creek Basin, a crystalline fractured rock aquifer located 30 km southwest of Denver, Colorado. Analyses indicate RES does not correlate to rock type or local relief in several instances but is generally lower within incised creek valleys and higher along mountain fronts. Results of this study suggest that (1) CRWN is an effective and computationally efficient method to estimate uncertainty, (2) RES predictions are well constrained using uncertainty analysis, and (3) for aquifers such as Turkey Creek Basin, spatial variability of RES is significant and complex.

  5. Reduction of Zygomatic Fractures Using the Carroll-Girard T-bar Screw.

    PubMed

    Baek, Ji Eun; Chung, Chan Min; Hong, In Pyo

    2012-09-01

    Zygomatic fractures are the second most common facial bone fractures encountered and treated by plastic surgeons. Stable fixation of fractured fragments after adequate exposure is critical for ensuring three-dimensional anatomic reduction. Between January 2008 and December 2010, 17 patients with zygomatic fractures were admitted to our hospital; there were 15 male and 2 female patients. The average age of the patients was 41 years (range, 19 to 75 years). We exposed the inferior orbital rim and zygomatic complex through a lateral brow, intraoral, and subciliary incisions, which allowed for visualization of the bone, and then the fractured parts were corrected using the Carroll-Girard T-bar screw. Postoperative complications such as malar asymmetry, diplopia, enophthalmos, and postoperative infection were not observed. Lower eyelid retraction and temporary ectropion occurred in 1 of the 17 patients. Functional and cosmetic results were excellent in nearly all of the cases. In this report, we describe using the Carroll-Girard T-bar screw for the reduction of zygomatic fractures. Because this instrument is easy to use and can rotate to any direction and vector, it can be used to correct displaced zygomatic bone more accurately and safely than other devices, without leaving facial scars.

  6. Hidden contributions of the enamel rods on the fracture resistance of human teeth

    PubMed Central

    Yahyazadehfar, M.; Bajaj, Devendra; Arola, Dwayne D.

    2013-01-01

    The enamel of human teeth is generally regarded as a brittle material with low fracture toughness. Consequently, the contributions of this tissue in resisting tooth fracture and the importance of its complex microstructure have been largely overlooked. In this study an experimental evaluation of the crack growth resistance of human enamel was conducted to characterize the role of rod (i.e. prism) orientation and degree of decussation on the fracture behavior of this tissue. Incremental crack growth was achieved in-plane, with the rods in directions longitudinal or transverse to their axes. Results showed that the fracture resistance of enamel is both inhomogeneous and spatially anisotropic. Cracks extending transverse to the rods in the outer enamel undergo a lower rise in toughness with extension, and achieve significantly lower fracture resistance than in the longitudinal direction. Though cracks initiating at the surface of teeth may begin extension towards the dentin–enamel junction, they are deflected by the decussated rods and continue growth about the tooth’s periphery, transverse to the rods in the outer enamel. This process facilitates dissipation of fracture energy and averts cracks from extending towards the dentin and vital pulp. PMID:23022547

  7. The Applications of Finite Element Analysis in Proximal Humeral Fractures.

    PubMed

    Ye, Yongyu; You, Wei; Zhu, Weimin; Cui, Jiaming; Chen, Kang; Wang, Daping

    2017-01-01

    Proximal humeral fractures are common and most challenging, due to the complexity of the glenohumeral joint, especially in the geriatric population with impacted fractures, that the development of implants continues because currently the problems with their fixation are not solved. Pre-, intra-, and postoperative assessments are crucial in management of those patients. Finite element analysis, as one of the valuable tools, has been implemented as an effective and noninvasive method to analyze proximal humeral fractures, providing solid evidence for management of troublesome patients. However, no review article about the applications and effects of finite element analysis in assessing proximal humeral fractures has been reported yet. This review article summarized the applications, contribution, and clinical significance of finite element analysis in assessing proximal humeral fractures. Furthermore, the limitations of finite element analysis, the difficulties of more realistic simulation, and the validation and also the creation of validated FE models were discussed. We concluded that although some advancements in proximal humeral fractures researches have been made by using finite element analysis, utility of this powerful tool for routine clinical management and adequate simulation requires more state-of-the-art studies to provide evidence and bases.

  8. Biological Perspectives of Delayed Fracture Healing

    PubMed Central

    Hankenson, KD; Zmmerman, G; Marcucio, R

    2015-01-01

    Fracture healing is a complex biological process that requires interaction among a series of different cell types. Maintaining the appropriate temporal progression and spatial pattern is essential to achieve robust healing. We can temporally assess the biological phases via gene expression, protein analysis, histologically, or non-invasively using biomarkers as well as imaging techniques. However, determining what leads to normal verses abnormal healing is more challenging. Since the ultimate outcome of the process of fracture healing is to restore the original functions of bone, assessment of fracture healing should include not only monitoring the restoration of structure and mechanical function, but also an evaluation of the restoration of normal bone biology. Currently very few non-invasive measures of the biology of healing exist; however, recent studies that have correlated non-invasive measures with fracture healing outcome in humans have shown that serum TGFbeta1 levels appear to be an indicator of healing vs non-healing. In the future, developing additional serum measures to assess biological healing will improve the reliability and permit us to assess stages of fracture healing. Additionally, new functional imaging technologies could prove useful for better understanding both normal fracture healing and predicting dysfunctional healing in human patients. PMID:24857030

  9. Three-part head-splitting proximal humerus fracture through a unicameral bone cyst.

    PubMed

    Younghein, John A; Eskander, Mark S; DeAngelis, Nicola A; Wixted, John J

    2012-06-01

    Unicameral bone cysts are rare in adults and are most often found incidentally on radiographs. However, they can persist from the adolescent period and may be present in locations that predispose to or exacerbate fractures.This article describes a case of a healthy 40-year-old woman who sustained a proximal humerus trauma that involved a large unicameral bone cyst, resulting in a 3-part head-splitting fracture. The epiphyseal location of the cyst contributed to the severity and extent of the fracture that resulted from a simple fall. Given the age of the patient, open reduction and internal fixation with a locking plate and lag screws was performed. The patient chose open reduction and internal fixation to preserve a hemiarthroplasty procedure in case of future revision. Successful humeral head reconstruction was achieved, and the patient fully recovered. One year postoperatively, the patient underwent arthroscopic debridement to alleviate subjective stiffness and decreased range of motion.Multipart head-splitting fractures require complex repair strategies. The gold standard for the treatment of these injuries is hemiarthroplasty. However, the decision process is difficult in a young patient given the average survival of autoplastic prostheses and the added difficulty of later revision. The current case demonstrates the complexity of decision making resulting from a rare injury in a young, healthy patient and shows that open reduction and internal fixation can provide acceptable reconstruction in such situations. Copyright 2012, SLACK Incorporated.

  10. Microfluidic Investigation of Oil Mobilization in Shale Fracture Networks at Reservoir Conditions

    NASA Astrophysics Data System (ADS)

    Porter, M. L.; Jimenez-Martinez, J.; Carey, J. W.; Viswanathan, H. S.

    2015-12-01

    Investigations of pore-scale fluid flow and transport phenomena using engineered micromodels has steadily increased in recent years. In these investigations fluid flow is restricted to two-dimensions allowing for real time visualization and quantification of complex flow and reactive transport behavior, which is difficult to obtain in other experimental systems. One drawback to these studies is the use of engineered materials that do not faithfully represent the rock properties (e.g., porosity, wettability, roughness, etc.) encountered in subsurface formations. In this work, we describe a unique high pressure (up to 1500 psi) and temperature (up to 80 °C) microfluidics experimental system in which we investigate fluid flow and transport in geo-material (e.g., shale, Portland cement, etc.) micromodels. The use of geo-material micromodels allows us to better represent fluid-rock interactions including wettability, chemical reactivity, and nano-scale porosity at conditions representative of natural subsurface environments. Here, we present experimental results in fracture systems with applications to hydrocarbon mobility in hydraulically fractured shale. Complex fracture network patterns are derived from 3D x-ray tomography images of actual fractures created in shale rock cores. We use both shale and glass micromodels, allowing for a detailed comparison between flow phenomena in the different materials. We discuss results from two-phase huff-and-puff experiments involving N2 and n-Decane, as well as three-phase displacement experiments involving supercritical CO2, brine, and n-Decane.

  11. Quantifying Discrete Fracture Network Connectivity in Hydraulic Fracturing Stimulation

    NASA Astrophysics Data System (ADS)

    Urbancic, T.; Ardakani, E. P.; Baig, A.

    2017-12-01

    Hydraulic fracture stimulations generally result in microseismicity that is associated with the activation or extension of pre-existing microfractures and discontinuities. Microseismic events acquired under 3D downhole sensor coverage provide accurate event locations outlining hydraulic fracture growth. Combined with source characteristics, these events provide a high quality input for seismic moment tensor inversion and eventually constructing the representative discrete fracture network (DFN). In this study, we investigate the strain and stress state, identified fracture orientation, and DFN connectivity and performance for example stages in a multistage perf and plug completion in a North American shale play. We use topology, the familiar concept in many areas of structural geology, to further describe the relationships between the activated fractures and their effectiveness in enhancing permeability. We explore how local perturbations of stress state lead to the activation of different fractures sets and how that effects the DFN interaction and complexity. In particular, we observe that a more heterogeneous stress state shows a higher percentage of sub-horizontal fractures or bedding plane slips. Based on topology, the fractures are evenly distributed from the injection point, with decreasing numbers of connections by distance. The dimensionless measure of connection per branch and connection per line are used for quantifying the DFN connectivity. In order to connect the concept of connectivity back to productive volume and stimulation efficiency, the connectivity is compared with the character of deformation in the reservoir as deduced from the collective behavior of microseismicity using robustly determined source parameters.

  12. A Discrete Fracture Network Model with Stress-Driven Nucleation and Growth

    NASA Astrophysics Data System (ADS)

    Lavoine, E.; Darcel, C.; Munier, R.; Davy, P.

    2017-12-01

    The realism of Discrete Fracture Network (DFN) models, beyond the bulk statistical properties, relies on the spatial organization of fractures, which is not issued by purely stochastic DFN models. The realism can be improved by injecting prior information in DFN from a better knowledge of the geological fracturing processes. We first develop a model using simple kinematic rules for mimicking the growth of fractures from nucleation to arrest, in order to evaluate the consequences of the DFN structure on the network connectivity and flow properties. The model generates fracture networks with power-law scaling distributions and a percentage of T-intersections that are consistent with field observations. Nevertheless, a larger complexity relying on the spatial variability of natural fractures positions cannot be explained by the random nucleation process. We propose to introduce a stress-driven nucleation in the timewise process of this kinematic model to study the correlations between nucleation, growth and existing fracture patterns. The method uses the stress field generated by existing fractures and remote stress as an input for a Monte-Carlo sampling of nuclei centers at each time step. Networks so generated are found to have correlations over a large range of scales, with a correlation dimension that varies with time and with the function that relates the nucleation probability to stress. A sensibility analysis of input parameters has been performed in 3D to quantify the influence of fractures and remote stress field orientations.

  13. Analysis of fluid flow and solute transport through a single fracture with variable apertures intersecting a canister: Comparison between fractal and Gaussian fractures

    NASA Astrophysics Data System (ADS)

    Liu, L.; Neretnieks, I.

    Canisters with spent nuclear fuel will be deposited in fractured crystalline rock in the Swedish concept for a final repository. The fractures intersect the canister holes at different angles and they have variable apertures and therefore locally varying flowrates. Our previous model with fractures with a constant aperture and a 90° intersection angle is now extended to arbitrary intersection angles and stochastically variable apertures. It is shown that the previous basic model can be simply amended to account for these effects. More importantly, it has been found that the distributions of the volumetric and the equivalent flow rates are all close to the Normal for both fractal and Gaussian fractures, with the mean of the distribution of the volumetric flow rate being determined solely by the hydraulic aperture, and that of the equivalent flow rate being determined by the mechanical aperture. Moreover, the standard deviation of the volumetric flow rates of the many realizations increases with increasing roughness and spatial correlation length of the aperture field, and so does that of the equivalent flow rates. Thus, two simple statistical relations can be developed to describe the stochastic properties of fluid flow and solute transport through a single fracture with spatially variable apertures. This obviates, then, the need to simulate each fracture that intersects a canister in great detail, and allows the use of complex fractures also in very large fracture network models used in performance assessment.

  14. [Clinical experience with various techniques integrated treat the wounded with gunshot fractures of limbs].

    PubMed

    Kozlov, V K; Akhmedov, B G; Chililov, A M

    To increase an efficiency of complex treatment of patients with diaphyseal gunshot fractures of long bones by introduction of modern minimally invasive surgical techniques of internal osteosynthesis into clinical practice of civil health care and to improve the outcomes in victims. Prospective comparative clinical trial included 104 victims from the Republic of Yemen with gunshot wounds of limbs of various severity for the period 2009-2011. There were diaphyseal fractures of long bones of limbs associated with soft tissue injuries. Men were predominant (80.7%). Age ranged from 15 to 80 years (mean 38,5 ± 5,7 years). Various surgical techniques of simultaneous and staged treatment were used for gunshot fractures of long bones of limbs. Additional immune therapy was prescribed to prevent infectious complications in the most severe cases. Victims were comprehensively treated according to different staged treatment: conventional surgical treatment with external fixation devices or early primary minimally invasive functionally stable osteosynthesis with LCP/BIOS plates were applied for low-energy fractures; in case of high-energy fractures the first stage included external fixation devices deployment followed by their subsequent replacement during delayed minimally invasive osteosynthesis. The essence of improvement is pursuit to simultaneous minimally invasive surgery by using of current plates for osteosynthesis and preventive immunotherapy of immune dysfunction to eliminate infectious complications. As a result, we obtained 2-fold decrease of surgical invasiveness (r≤0,01) and hospital-stay (r≤0,01). Repeated osteosynthesis was not made. Also 4-fold and 40-fold reduction of infectious and noninfectious complications was observed. This management was accompanied by reduced rehabilitation tine and significantly improved quality of life. Improved technique and algorithm of complex treatment of diaphyseal gunshot fractures of long bones of limbs were described. Early minimally invasive functionally stable osteosynthesis with modern implants and non-specific immune prevention of infectious complications are more effective and economically justified compared with conventional treatment including external fixation devices without immunoactive therapy.

  15. High-Resolution Experimental Investigation of mass transfer enhancement by chemical oxidation from DNAPL entrapped in variable-aperture fractures

    NASA Astrophysics Data System (ADS)

    Arshadi, M.; Rajaram, H.; Detwiler, R. L.; Jones, T.

    2012-12-01

    Permanganate oxidation of DNAPL- contaminated fractured rock is an effective remediation technology. Permanganate ion reacts with dissolved DNAPL in a bi-molecular oxidation-reduction reaction. The consumption of dissolved DNAPL in this reaction results in increased concentration gradients away from the free-phase DNAPL, resulting in reaction-enhanced mass transfer, which accelerates contaminant removal. The specific objective of our research was to perform high-resolution non-intrusive experimental studies of permanganate oxidation in a 15.24 × 15.24 cm, transparent, analog, variable-aperture fracture with complex initial TCE entrapped phase geometry. Our experimental system uses light-transmission techniques to accurately measure both fracture aperture and the evolution of individual entrapped DNAPL blobs during the remediation experiments at high resolution (pixel size : 6.2×10-3 cm). Three experiments were performed with different flow rates and permanganate inflow concentrations to observe DNAPL-permanganate interactions across a broader range of conditions. Prior to initiating each experiment, the aperture field within the fracture was measured. The oxidation experiment was initiated by TCE injection into the water saturated fracture till the TCE reached the outflow end, followed by water re-injection through the fracture. The flowing water mobilized some TCE. We continued injection of water till TCE mobilization ceased, leaving behind the residual TCE entrapped within the variable-aperture fracture. Subsequently, permanganate injection through the fracture resulted in propagation of a fingered reaction front into the fracture. We developed image processing algorithms to analyze the evolution of DNAPL phase geometry over the duration of the experiment. The permanganate consumption rate varied significantly within the fracture due to the complex flow and DNAPL concentration fields. Precipitated MnO2 was clearly evident on the downstream side of DNAPL blobs near the inflow boundary indicating high reaction rates in these regions. This behavior is explained by the diversion of permanganate around entrapped DNAPL blobs and downstream advection of dissolved DNAPL. Our results indicate that the total rate of mass transfer from the DNAPL blobs is higher at early times, when not much MnO2 has formed and precipitated. With time, MnO2 precipitation in the fracture leads to changes the aperture field and flow field. Precipitated MnO2 around TCE blobs also decreases the DNAPL accessible surface area. By comparing the results of three experiments, we conclude that low permanganate concentrations and high flow rates lead to more efficient DNAPL remediation, resulting from the fact that under these conditions there would be slower MnO2 formation and less precipitation within the fracture. We also present results on the time-evolution of fracture-scale permanganate consumption and DNAPL removal rates. The experimental observations are being used to develop improved high-resolution numerical models of reactive transport in variable-aperture fractures. The overall goal is to relate the coupled processes of DNAPL removal, permanganate consumption, MnO2 formation and associated changes in aperture and interface area; to derive fracture-scale effective representations of these processes.

  16. Reverse total shoulder arthroplasty for acute head-splitting, 3- and 4-part fractures of the proximal humerus in the elderly.

    PubMed

    Grubhofer, Florian; Wieser, Karl; Meyer, Dominik C; Catanzaro, Sabrina; Beeler, Silvan; Riede, Ulf; Gerber, Christian

    2016-10-01

    Anatomic reduction and stable internal fixation of complex proximal humeral fractures in the elderly is challenging. Secondary displacement, screw perforation, and humeral head necrosis are common complications. The outcome of hemiarthroplasty is unpredictable and strongly dependent on the uncertain healing of the greater tuberosity. This multicenter study retrospectively analyzes the midterm results of primary reverse total shoulder arthroplasty for the treatment of acute, complex fractures of the humerus in an elderly population. Fifty-two shoulders in 51 patients with a mean age of 77 years treated with reverse total shoulder arthroplasty for an acute, complex fracture of the proximal humerus were clinically and radiographically analyzed after a mean follow-up period of 35 months (range, 12-90 months). There were no intraoperative complications. Revision surgery was performed in 4 shoulders. At final follow-up, the absolute and relative Constant scores averaged 62 points (range, 21-83 points) and 86% (range, 30%-100%), respectively, with a mean Subjective Shoulder Value of 83% (range, 30%-100%). Of the patients, 92% rated the treatment outcome as excellent or good. Patients with a resected or secondarily displaced greater tuberosity had an inferior clinical outcome to those with a healed greater tuberosity. The midterm clinical results are predictably good, with low complication rates and a rapid postoperative recovery of painfree everyday function. If secondary displacement of the greater tuberosity occurs, revision surgery may warrant consideration in view of potential improvement of ultimate outcome. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. Avianca flight No. 052 accident: a plastic surgical perspective.

    PubMed

    Greenberg, B M; Brewer, B W

    1991-09-01

    The crash of Avianca Airlines flight no. 052 en route to JFK Airport on January 25, 1990, in Cove Neck, New York, resulted in the death of 72 passengers. Eighty-nine victims were admitted to 13 regional hospitals. Despite difficult access to the wooded crash site, early warning and prompt response by 37 volunteer fire and rescue units resulted in organized EMS triage and rapid hospital transport. This report reviews the specific injuries incurred, highlights the team management approach to a major aviation accident in a suburban area, and studies the likelihood of accidents of this magnitude. Thirty-eight patients triaged to two level I trauma centers, North Shore University Hospital-Cornell University Medical Center and Nassau County Medical Center, form the basis of this report. Seventeen patients were male; 21 were female. The average patient age was 33 years. Eight patients were children. The average length of stay was 30.9 days (range 2 to greater than 90 days). Twenty-six patients (including nonsurvivors) (68 percent) sustained significant multiple orthopedic injuries. The majority of fractures were open grade II to III tibia-fibula fractures. Bilaterality was commonly seen. Soft-tissue coverage of open long bone fractures was required in 10 patients (11 extremities) and included 3 microvascular muscle transfers, 7 muscle transposition flaps, and 3 skin grafts. Seven patients required open reduction and fixation of complex facial fractures (two of Le Fort II to III type, four of complex naso-orbital-ethmoid type). Plastic surgical repair of complex lacerations was common. Peripheral nerve exploration was required in three patients.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. The fluid mechanics of channel fracturing flows: experiment

    NASA Astrophysics Data System (ADS)

    Rashedi, Ahmadreza; Tucker, Zachery; Ovarlez, Guillaume; Hormozi, Sarah

    2017-11-01

    We show our preliminary experimental results on the role of fluid mechanics in channel fracturing flows, particularly yield stress fracturing fluids. Recent trends in the oil industry have included the use of cyclic pumping of a proppant slurry interspersed with a yield stress fracturing fluid, which is found to increase wells productivity, if particles disperse in a certain fashion. Our experimental study aims to investigate the physical mechanisms responsible for dispersing the particles (proppant) within a yield stress carrier fluid, and to measure the dispersion of proppant slugs in various fracturing regimes. To this end we have designed and built a unique experimental setup that resembles a fracture configuration coupled with a particle image/tracking velocimetry setup operating at micro to macro dimensions. Moreover, we have designed optically engineered suspensions of complex fluids with tunable yield stress and consistency, well controlled density match-mismatch properties and refractive indices for both X-rays and visible lights. We present our experimental system and preliminary results. NSF (Grant No. CBET-1554044- CAREER), ACS PRF (Grant No. 55661-DNI9).

  19. The design, production and clinical application of 3D patient-specific implants with drilling guides for acetabular surgery.

    PubMed

    Merema, B J; Kraeima, J; Ten Duis, K; Wendt, K W; Warta, R; Vos, E; Schepers, R H; Witjes, M J H; IJpma, F F A

    2017-11-01

    An innovative procedure for the development of 3D patient-specific implants with drilling guides for acetabular fracture surgery is presented. By using CT data and 3D surgical planning software, a virtual model of the fractured pelvis was created. During this process the fracture was virtually reduced. Based on the reduced fracture model, patient-specific titanium plates including polyamide drilling guides were designed, 3D printed and milled for intra-operative use. One of the advantages of this procedure is that the personalised plates could be tailored to both the shape of the pelvis and the type of fracture. The optimal screw directions and sizes were predetermined in the 3D model. The virtual plan was translated towards the surgical procedure by using the surgical guides and patient-specific osteosynthesis. Besides the description of the newly developed multi-disciplinary workflow, a clinical case example is presented to demonstrate that this technique is feasible and promising for the operative treatment of complex acetabular fractures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Microstructure-dependent fracture toughness (JIC) variations in dissimilar pipe welds for pressure vessel system of nuclear plants

    NASA Astrophysics Data System (ADS)

    Rathod, Dinesh W.; Pandey, Sunil; Singh, P. K.; Kumar, Suranjit

    2017-09-01

    In present study, dissimilar metal weld (DMW) joints between SA508Gr.3cl.1 ferritic steel and SS304LN pipes were prepared using Inconel 82/182, and Inconel 52/152 consumables. Metallurgical properties and their influence on fracture toughness of weldment regions and interfacial regions could play a significant role in integrity assessment of these joints. Ni-based consumables exhibit complex metallurgical properties at interfacial regions. The metallurgical characterization and fracture toughness studies of Inconel 82/182 and Inconel 52/152 joints have been carried out for determining the optimum consumable for DMW joint requirements and the effect of microstructure on fracture toughness in weldment regions. The present codes and procedures for integrity assessment of DMW joints have not given due considerations of metallurgical properties. The requirements for metallurgical properties by considering their effect on fracture toughness properties in integrity assessment have been discussed for reliable analysis. Inconel 82/182 is preferred over Inconel 52/152 joints owing to favorable metallurgical and fracture toughness properties across the interfacial and weldment regions.

  1. Role of chemical and mechanical stimuli in mediating bone fracture healing.

    PubMed

    Zhang, Lihai; Richardson, Martin; Mendis, Priyan

    2012-08-01

    Bone is a remarkable living tissue that provides a framework for animal body support and motion. However, under excessive loads and deformations, bone is prone is to damage through fracture. Furthermore, once the bone is weakened by osteoporosis, bone fracture can occur even after only minimal trauma. Various techniques have been developed to treat bone fractures. Successful treatment outcomes depend on a fundamental understanding of the biochemical and biomechanical environments of the fracture site. Various cell types (e.g. mesenchymal stem cells, chondrocytes, osteoblasts and osteoclasts) within the fracture site tightly control the healing process by responding to the chemical and mechanical microenvironment. However, these mechanochemical regulatory mechanisms remain poorly understood at the system level owing to the large range of variables, such as age, sex and disease-associated material properties of the tissue. Computational modelling can play an important role in unravelling this complexity by combining mechanochemical interactions, revealing the dominant controlling processes and optimizing system behaviour, thereby enabling the development and evaluation of treatment strategies for individual patients. © 2011 The Authors. Clinical and Experimental Pharmacology and Physiology © 2011 Blackwell Publishing Asia Pty Ltd.

  2. Minimally invasive plating osteosynthesis for mid-distal third humeral shaft fractures.

    PubMed

    Lian, Kejian; Wang, Lei; Lin, Dasheng; Chen, Zhiwen

    2013-08-01

    Mid-distal third humeral shaft fractures can be effectively treated with minimally invasive plating osteosynthesis and intramedullary nailing (IMN). However, these 2 treatments have not been adequately compared. Forty-seven patients (47 fractures) with mid-distal third humeral shaft fractures were randomly allocated to undergo either minimally invasive plating osteosynthesis (n=24) or IMN (n=23). The 2 groups were similar in terms of fracture patterns, fracture location, age, and associated injuries. Intraoperative measurements included blood loss and operative time. Clinical outcome measurements included fracture healing, radial nerve recovery, and elbow and shoulder discomfort. Radiographic measurements included fracture alignment, time to healing, delayed union, and nonunion. Functional outcome was satisfactory in both groups. Mean American Shoulder and Elbow Surgeons score and Mayo score were both better for the minimally invasive plating osteosynthesis group than for the IMN group (98.2 vs 97.6, respectively, and 93.5 vs 94.1, respectively; P<.001). Operative time was shorter and less intraoperative blood loss occurred in the minimally invasive plating osteosynthesis group than in the IMN group. Average time to union was similar in both groups. Primary union was achieved in 23 of 24 patients in the minimally invasive plating osteosynthesis group and in 22 of 23 in the IMN group. Minimally invasive plating osteosynthesis may have outcomes comparable with IMN for the management of mid-distal third humeral shaft fractures. Minimally invasive plating osteosynthesis is more suitable for complex fractures, especially for radial protection and motion recovery of adjacent joints, compared with IMN for simple fractures. Copyright 2013, SLACK Incorporated.

  3. Impact of intraprosthetic drilling on the strength of the femoral stem in periprosthetic fractures: A finite element investigation.

    PubMed

    Brand, Stephan; Bauer, Michael; Petri, Maximilian; Schrader, Julian; Maier, Hans J; Krettek, Christian; Hassel, Thomas

    2016-07-01

    Treatment of periprosthetic femur fractures after total hip arthroplasty remains a major challenge in orthopedic surgery. Recently, a novel surgical technique using intraprosthetic screw fixation has been suggested. The purpose of this study was to evaluate the influence of drilling the femoral hip stem on integrity and strength of the implant. The hypothesis was that intraprosthetic drilling and screw fixation would not cause the load limit of the prosthesis to be exceeded and that deformation would remain within the elastic limit. A sawbone model with a conventional straight hip stem was used and a Vancouver C periprosthetic fracture was created. The fracture was fixed with a nine-hole less invasive stabilization system plate with two screws drilled and inserted through the femoral hip stem. Three different finite element models were created using ANSYS software. The models increased in complexity including joint forces and stress risers from three different dimensions. A variation of drilling positions was analyzed. Due to the complexity of the physiological conditions in the human femur, the most complex finite element model provided the most realistic results. Overall, significant changes in the stresses to the prosthesis caused by the drilling procedure were observed. While the stresses at the site of the bore hole decreased, the load increased in the surrounding stem material. This effect is more pronounced and further the holes were apart, and it was found that increasing the number of holes could counteract this. The maximum load was still found to be in the area of the prosthesis neck. No stresses above the load limit of titanium alloy were detected. All deformations of the prosthesis stem remained in the elastic range. These results may indicate a potential role for intraprosthetic screw fixation in the future treatment of periprosthetic femur fractures. © IMechE 2016.

  4. Detailed study of seismic wave attenuation from four oilfields in Abu Dhabi, United Arab Emirates

    NASA Astrophysics Data System (ADS)

    Bouchaala, F.; Ali, M. Y.; Matsushima, J.

    2018-02-01

    In the present study, we provide a detailed study of seismic wave attenuation obtained from four oilfields. The reservoir zones of these oilfields are complicated due to complex fracture networks, the presence of tar mat and high heterogeneity of carbonate rocks of which the subsurface of Abu Dhabi is mainly composed. These complexities decrease signal-to-noise ratio and make attenuation estimation difficult. We obtained high-resolution attenuation profiles from vertical seismic profiling (VSP) and sonic waveform data. The VSP data were recorded in all four oilfields and the sonic data were acquired in the reservoir zones of oilfields I and IV. We found that the VSP scattering attenuation ({Q}{{S}{{c}}{{a}}{{t}}}-1) varies from -0.080 to 0.180 over a depth range of 400-3500 m. We attributed this significant scattering to the high heterogeneity of carbonate rocks. The scattering profiles seem to be sensitive to fractures, lithology heterogeneity and tar mat, but their effect is superimposed. The VSP intrinsic attenuation varies from -0.15 to 0.246 with high variation within each formation. Since intrinsic attenuation is closely related to fluids, we assumed that this variation is due to the non-uniform distribution of fluids caused by the complex porosity network of the subsurface. The sonic monopole attenuation ({Q}{{M}{{f}}}-1) in the reservoir zones ranges between 0.033-0.094 and dipole inline attenuation ({Q}{{I}{{n}}{{l}}}-1) ranges from 0.040-0.138. The sonic attenuation appears to be sensitive to the presence of fluid and type of fractures, where it shows high attenuation for open fractures and low attenuation for resistive fractures. The zones with high clay content display high sonic intrinsic attenuation in the reservoir of oilfield II. We explain this by the frictional movement between the clay and carbonates due to the elasticity contrast of these two materials. Therefore, the solid grain friction may be the dominant attenuation mechanism in those zones.

  5. Hydraulic fracturing in shales: the spark that created an oil and gas boom

    NASA Astrophysics Data System (ADS)

    Olson, J. E.

    2017-12-01

    In the oil and gas business, one of the valued properties of a shale was its lack of flow capacity (its sealing integrity) and its propensity to provide mechanical barriers to hydraulic fracture height growth when exploiting oil and gas bearing sandstones. The other important property was the high organic content that made shale a potential source rock for oil and gas, commodities which migrated elsewhere to be produced. Technological advancements in horizontal drilling and hydraulic fracturing have turned this perspective on its head, making shale (or other ultra-low permeability rocks that are described with this catch-all term) the most prized reservoir rock in US onshore operations. Field and laboratory results have changed our view of how hydraulic fracturing works, suggesting heterogeneities like bedding planes and natural fractures can cause significant complexity in hydraulic fracture growth, resulting in induced networks of fractures whose details are controlled by factors including in situ stress contrasts, ductility contrasts in the stratigraphy, the orientation and strength of pre-existing natural fractures, injection fluid viscosity, perforation cluster spacing and effective mechanical layer thickness. The stress shadowing and stress relief concepts that structural geologists have long used to explain joint spacing and orthogonal fracture pattern development in stratified sequences are key to understanding optimal injection point spacing and promotion of more uniform length development in induced hydraulic fractures. Also, fracture interaction criterion to interpret abutting vs crossing natural fracture relationships in natural fracture systems are key to modeling hydraulic fracture propagation within natural fractured reservoirs such as shale. Scaled physical experiments provide constraints on models where the physics is uncertain. Numerous interesting technical questions remain to be answered, and the field is particularly appealing in that better geologic understanding of the stratigraphic heterogeneity and material property attributes of shale can have a direct effect on the engineering design of wellbores and stimulation treatments.

  6. Use of the Fracture Continuum Model for Numerical Modeling of Flow and Transport of Deep Geologic Disposal of Nuclear Waste in Crystalline Rock

    NASA Astrophysics Data System (ADS)

    Hadgu, T.; Kalinina, E.; Klise, K. A.; Wang, Y.

    2015-12-01

    Numerical modeling of disposal of nuclear waste in a deep geologic repository in fractured crystalline rock requires robust characterization of fractures. Various methods for fracture representation in granitic rocks exist. In this study we used the fracture continuum model (FCM) to characterize fractured rock for use in the simulation of flow and transport in the far field of a generic nuclear waste repository located at 500 m depth. The FCM approach is a stochastic method that maps the permeability of discrete fractures onto a regular grid. The method generates permeability fields using field observations of fracture sets. The original method described in McKenna and Reeves (2005) was designed for vertical fractures. The method has since then been extended to incorporate fully three-dimensional representations of anisotropic permeability, multiple independent fracture sets, and arbitrary fracture dips and orientations, and spatial correlation (Kalinina et al. 20012, 2014). For this study the numerical code PFLOTRAN (Lichtner et al., 2015) has been used to model flow and transport. PFLOTRAN solves a system of generally nonlinear partial differential equations describing multiphase, multicomponent and multiscale reactive flow and transport in porous materials. The code is designed to run on massively parallel computing architectures as well as workstations and laptops (e.g. Hammond et al., 2011). Benchmark tests were conducted to simulate flow and transport in a specified model domain. Distributions of fracture parameters were used to generate a selected number of realizations. For each realization, the FCM method was used to generate a permeability field of the fractured rock. The PFLOTRAN code was then used to simulate flow and transport in the domain. Simulation results and analysis are presented. The results indicate that the FCM approach is a viable method to model fractured crystalline rocks. The FCM is a computationally efficient way to generate realistic representation of complex fracture systems. This approach is of interest for nuclear waste disposal models applied over large domains.

  7. Tuning Fractures With Dynamic Data

    NASA Astrophysics Data System (ADS)

    Yao, Mengbi; Chang, Haibin; Li, Xiang; Zhang, Dongxiao

    2018-02-01

    Flow in fractured porous media is crucial for production of oil/gas reservoirs and exploitation of geothermal energy. Flow behaviors in such media are mainly dictated by the distribution of fractures. Measuring and inferring the distribution of fractures is subject to large uncertainty, which, in turn, leads to great uncertainty in the prediction of flow behaviors. Inverse modeling with dynamic data may assist to constrain fracture distributions, thus reducing the uncertainty of flow prediction. However, inverse modeling for flow in fractured reservoirs is challenging, owing to the discrete and non-Gaussian distribution of fractures, as well as strong nonlinearity in the relationship between flow responses and model parameters. In this work, building upon a series of recent advances, an inverse modeling approach is proposed to efficiently update the flow model to match the dynamic data while retaining geological realism in the distribution of fractures. In the approach, the Hough-transform method is employed to parameterize non-Gaussian fracture fields with continuous parameter fields, thus rendering desirable properties required by many inverse modeling methods. In addition, a recently developed forward simulation method, the embedded discrete fracture method (EDFM), is utilized to model the fractures. The EDFM maintains computational efficiency while preserving the ability to capture the geometrical details of fractures because the matrix is discretized as structured grid, while the fractures being handled as planes are inserted into the matrix grids. The combination of Hough representation of fractures with the EDFM makes it possible to tune the fractures (through updating their existence, location, orientation, length, and other properties) without requiring either unstructured grids or regridding during updating. Such a treatment is amenable to numerous inverse modeling approaches, such as the iterative inverse modeling method employed in this study, which is capable of dealing with strongly nonlinear problems. A series of numerical case studies with increasing complexity are set up to examine the performance of the proposed approach.

  8. How reactive fluids alter fracture walls and affect shale-matrix accessibility

    NASA Astrophysics Data System (ADS)

    Fitts, J. P.; Deng, H.; Peters, C. A.

    2014-12-01

    Predictions of mass transfer across fracture boundaries and fluid flow in fracture networks provide fundamental inputs into risk and life cycle assessments of geologic energy technologies including oil and gas extraction, geothermal energy systems and geologic CO2 storage. However, major knowledge gaps exist due to the lack of experimental observations of how reactive fluids alter the pore structures and accessible surface area within fracture boundaries that control the mass transfer of organics, metals and salts, and influence fluid flow within the fracture. To investigate the fracture and rock matrix properties governing fracture boundary alteration, we developed a new flow-through cell that enables time-dependent 2D x-ray imaging of mineral dissolution and/or precipitation at a fracture surface. The parallel plate design provides an idealized fracture geometry to investigate the relationship between flow rate, reaction rate, and mineral spatial heterogeneity and variation. In the flow-cell, a carbonate-rich sample of Eagle Ford shale was reacted with acidified brine. The extent and rate of mineral dissolution were correlated with calcite abundance relative to less soluble silicate minerals. Three-dimensional x-ray tomography of the reacted fracture wall shows how calcite dissolution left behind a porous network of silicate minerals. And while this silicate network essentially preserved the location of the initial fracture wall, the pore network structures within the fracture boundary were dramatically altered, such that the accessible surface area of matrix components increased significantly. In a second set of experiments with a limestone specimen, however, the extent of dissolution and retreat of the fracture wall was not strictly correlated with the occurrence of calcite. Instead, the pattern and extent of dissolution suggested secondary causes such as calcite morphology, the presence of argillaceous minerals and other diagenetic features. Our experiments show that while calcite dissolution is the primary geochemical driver of fracture wall alterations, hydrodynamic properties and matrix accessibility within fracture boundaries evolve based on a complex relationship between mineral spatial heterogeneity and variation, fluid chemistry and flow rate.

  9. Micro-fracture Behavior of Organic Matters in Kerogen-Rich Shale (KRS) Composites from Micro- to Milli-meter Scales

    NASA Astrophysics Data System (ADS)

    Haque, M. H.; Han, Y.; Hull, K. L.; Abousleiman, Y. N.

    2017-12-01

    Understanding the failure behavior of kerogen-rich shale (KRS) at multiscale is critical to efficient hydraulic fracture stimulations in unconventional source shale reservoirs. As a composite material consisting of compacted clay particles, silt-sized grains, and organic matter (OM), KRS is highly complex both structurally and mechanically. The OM, which is intertwined within the shale matrix, presents a particular challenge as it can be much more compliant than its surrounding minerals while at the same time have a significantly higher tensile strength. The mode-I fracture toughness and tensile failure behavior of KRS has been studied at the core scale by traditional rock mechanics methods i.e., Brazilian tests and more recently with non-traditional approaches at the micro-scale using nanoindentation techniques. However, core scale testing fails in precisely capturing the effects of OM due to its coarse resolution, while nanoindention may capture the behavior of isolated component but in some cases miss the collective properties of the composite system. To bridge this gap, while still complying with ASTM/ISRM standards in principle, we investigate fracture initiation and propagation in KRS using the single-edge notched beam (SENB) miniature samples with span length in the millimeter scale. The size scale attempts to isolate the contributions from individual components, especially the OM, to the emergent and systematic fracturing behavior of KRS. Crack propagation along and across the bedding planes have left noticeable signatures on fractured OM while travelling through and around an OM body depending upon its size and spatial position along the crack path illustrating what looks like crack arrest and/or crack bridging in a composite porous matrix. The fractured surface of OM, even being polymeric in nature, exhibits smooth and even surface profile when ripped apart but not in all observed surfaces. Unique microscale features such as- ridges, twists, and inclusions have also been observed for the OM indicating a mix of complex modes of failures. This study helps further the understanding of fracture morphologies in source rock reservoirs.

  10. Fracture heuristics: surgical decision for approaches to distal radius fractures. A surgeon's perspective.

    PubMed

    Wichlas, Florian; Tsitsilonis, Serafim; Kopf, Sebastian; Krapohl, Björn Dirk; Manegold, Sebastian

    2017-01-01

    Introduction: The aim of the present study is to develop a heuristic that could replace the surgeon's analysis for the decision on the operative approach of distal radius fractures based on simple fracture characteristics. Patients and methods: Five hundred distal radius fractures operated between 2011 and 2014 were analyzed for the surgeon's decision on the approach used. The 500 distal radius fractures were treated with open reduction and internal fixation through palmar, dorsal, and dorsopalmar approaches with 2.4 mm locking plates or underwent percutaneous fixation. The parameters that should replace the surgeon's analysis were the fractured palmar cortex, and the frontal and the sagittal split of the articular surface of the distal radius. Results: The palmar approach was used for 422 (84.4%) fractures, the dorsal approach for 39 (7.8%), and the combined dorsopalmar approach for 30 (6.0%). Nine (1.8%) fractures were treated percutaneously. The correlation between the fractured palmar cortex and the used palmar approach was moderate (r=0.464; p<0.0001). The correlation between the frontal split and the dorsal approach, including the dorsopalmar approach, was strong (r=0.715; p<0.0001). The sagittal split had only a weak correlation for the dorsal and dorsopalmar approach (r=0.300; p<0.0001). Discussion: The study shows that the surgical decision on the preferred approach is dictated through two simple factors, even in the case of complex fractures. Conclusion: When the palmar cortex is displaced in distal radius fractures, a palmar approach should be used. When there is a displaced frontal split of the articular surface, a dorsal approach should be used. When both are present, a dorsopalmar approach should be used. These two simple parameters could replace the surgeon's analysis for the surgical approach.

  11. Fracture patterns in the maxillofacial region: a four-year retrospective study

    PubMed Central

    2015-01-01

    Objectives The facial bones are the most noticeable area in the human body, and facial injuries can cause significant functional, aesthetic, and psychological complications. Continuous study of the patterns of facial bone fractures and changes in trends is helpful in the prevention and treatment of maxillofacial fractures. The purpose of the current clinico-statistical study is to investigate the pattern of facial fractures over a 4-year period. Materials and Methods A retrospective analysis of 1,824 fracture sites was carried out in 1,284 patients admitted to SMG-SNU Boramae Medical Center for facial bone fracture from January 2010 to December 2013. We evaluated the distributions of age/gender/season, fracture site, cause of injury, duration from injury to treatment, hospitalization period, and postoperative complications. Results The ratio of men to women was 3.2:1. Most fractures occurred in individuals aged between teens to 40s and were most prevalent at the middle and end of the month. Fractures occurred in the nasal bone (65.0%), orbital wall (29.2%), maxillary wall (15.3%), zygomatic arch (13.2%), zygomaticomaxillary complex (9.8%), mandibular symphysis (6.5%), mandibular angle (5.9%), mandibular condyle (4.9%), and mandibular body (1.9%). The most common etiologies were fall (32.5%) and assault (26.0%). The average duration of injury to treatment was 6 days, and the average hospitalization period was 5 days. Eighteen postoperative complications were observed in 17 patients, mainly infection and malocclusion in the mandible. Conclusion This study reflects the tendency for trauma in the Seoul metropolitan region because it analyzes all facial fracture patients who visited our hospital regardless of the specific department. Distinctively, in this study, midfacial fractures had a much higher incidence than mandible fractures. PMID:26734557

  12. Fractography applied to investigations of cores, outcrops, and fractured reservoirs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kulander, B.

    1995-11-01

    Fractography focuses investigations on the topography of fracture surfaces. This topography is composed of fractographic features produced by changing stress magnitudes and directions along the advancing crack tip. Fractographic features commonly useful in core and outcrop analysis include the origin, twist hackle, inclusion hackle, and rib marks. These structures develop during brittle failure by Mode I loading at the crack tip and act together to form a hackle plume. Fractographic components throughout the plume record the dynamic history of fracture development. Components show, to the limit of visual scale, the principal stress directions, as well as relative stress magnitudes andmore » propagation velocities, that existed at the advancing fracture front. This information contributes to more meaningful conclusions in fracture investigations. In core studies, fractography aids identification of induced and natural fractures. Induced fractures and fractographic features show distinct geometry with that of the core and reflect the effects of the core boundary, in-situ stresses, drilling stresses, and rock anisotropies. Certain drilling- and coring-induced fractures possess orientations and fractographic features that suggest the direction of minimum in-situ stress and that this direction may change abruptly within the drilled volume of rock. Cored natural fractures generally originated away from the bit and possess fractographic features that bear no geometerical relationship to core parameters. Abrupt changes of natural fracture strike and development of twist hackle suggest locally complex paleostress distributions. A combined knowledge of in-situ stress and natural fracture trends is useful in predicting reservoir permeability. In outcrop, fractographic features, including abutting relationships between joints, more readily depict order of development, intrastratum distribution of fracturing stress, and size for joints in any set.« less

  13. Percutaneous locking plates for fractures of the distal tibia: our experience and a review of the literature.

    PubMed

    Ahmad, Mudussar Abrar; Sivaraman, Alagappan; Zia, Ahmed; Rai, Amarjit; Patel, Amratlal D

    2012-02-01

    Distal tibial metaphyseal fractures pose many complexities. This study assessed the outcomes of distal tibial fractures treated with medial locking plates. Eighteen patients were selected based on the fracture pattern and classified using the AO classification and stabilized with an AO medial tibial locking plate. Time to fracture union, complications, and outcomes were assessed with the American Orthopedic Foot and Ankle Society Ankle score at 12 months. Sixteen of the 18 patients achieved fracture union, with 1 patient lost to follow-up. Twelve fractures united within 24 weeks, with an average union time of 23.1 weeks. Three delayed unions, two at 28 weeks and one at 56 weeks. The average time to union was 32 weeks in the smokers and 15.3 weeks in the nonsmokers. Five of the 18 patients (27%) developed complications. One superficial wound infection, and one chronic wound infection, resulting in nonunion at 56 weeks, requiring revision. Two patients required plate removal, one after sustaining an open fracture at the proximal end of the plate 6 months after surgery (postfracture union)and the other for painful hardware. One patient had implant failure of three proximal diaphyseal locking screws at the screwhead/neck junction, but successful fracture union. The average American Orthopedic Foot and Ankle Society ankle score was 88.8 overall, and 92.1 in fractures that united within 24 weeks. Distal tibial locking plates have high fracture union rates, minimum soft tissue complications, and good functional outcomes. The literature shows similar fracture union and complication rates in locking and nonlocking plates. Copyright © 2012 by Lippincott Williams & Wilkins

  14. Computational Failure Modeling of Lower Extremities

    DTIC Science & Technology

    2012-01-01

    bone fracture, ligament tear, and muscle rupture . While these injuries may seem well-defined through medical imaging, the process of injury and the...to vehicles from improvised explosives cause severe injuries to the lower extremities, in- cluding bone fracture, ligament tear, and muscle rupture ...modeling offers a powerful tool to explore the insult-to-injury process with high-resolution. When studying a complex dynamic process such as this, it is

  15. Modern Initial Management of Severe Limbs Trauma in War Surgery: Orthopaedic Damage Control

    DTIC Science & Technology

    2010-04-01

    avoid fat embolism , allow an optimal nursing and medical evacuation without any secondary functional consequences [3]. 2.2.1 Indications: The...decrease the risk of fat embolism . Modern Initial Management of Severe Limbs Trauma in War Surgery: “Orthopaedic Damage Control” RTO-MP-HFM-182 17...injuries. Orthopaedic Imperious: Multiple open shaft fractures with blood loss, complex epiphysal fractures requiring a long difficult surgical bloody

  16. Treatment of traumatic infra orbital nerve paresthesia

    PubMed Central

    Lone, Parveen Akhter; Singh, R. K.; Pal, U. S.

    2012-01-01

    This study was done to find out the role of topiramate therapy in infraorbital nerve paresthesia after miniplate fixation in zygomatic complxex fractures. A total 2 cases of unilateral zygomatic complex fracture, 2-3 weeks old with infra orbital nerve paresthesia were slected. Open reduction and plating was done in frontozygomaticregion. Antiepileptic drug tab topiramate was given in therapeutic doses and dose was increased slowly until functional recovery was noticed. PMID:23833503

  17. My Experience as a Foot and Ankle Trauma Surgeon in Montreal, Canada: What's Not in the Books.

    PubMed

    Leduc, Stéphane; Nault, Marie-Lyne; Rouleau, Dominique M; Hebert-Davies, Jonah

    2016-06-01

    Foot and ankle fractures are sometimes seen as routine and easy to treat. However, many fractures vary from typical patterns and require more complex management. Obtaining good outcomes in these situations can be challenging. Often, the difference between average and good results has to do with preoperative planning and good surgical technique. This article outlines numerous techniques and tricks that are not always mentioned in classic textbooks. It focuses on ankle, talus, calcaneus, and midfoot fractures, and discusses numerous techniques and aids to avoid potential problems that may be encountered intraoperatively. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Description of sorbing tracers transport in fractured media using the lattice model approach

    NASA Astrophysics Data System (ADS)

    Jiménez-Hornero, Francisco J.; Giráldez, Juan V.; Laguna, Ana

    2005-12-01

    The transport of contaminants in fractured media is a complex phenomenon with a great environmental impact. It has been described with several models, most of them based on complex partial differential equations, that are difficult to apply when equilibrium and nonequilibrium dynamics are considered in complex boundaries. With the aim of overcoming this limitation, a combination of two lattice Bathnagar, Gross and Krook (BGK) models, derived from the lattice Boltzmann model, is proposed in this paper. The fractured medium is assumed to be a single fissure in a porous rock matrix. The proposed approach permits us to deal with two processes with different length scales: advection-dispersion in the fissure and diffusion within the rock matrix. In addition to the mentioned phenomena, sorption reactions are also considered. The combined model has been tested using the experimental breakthrough curves obtained by Garnier et al. (Garnier, J.M., Crampon, N., Préaux, C., Porel, G., Vreulx, M., 1985. Traçage par 13C, 2H, I - et uranine dans la nappe de la craie sénonienne en écoulement radial convergent (Béthune, France). J. Hidrol. 78, 379-392.) giving acceptable results. A study on the influence of the lattice BGK models parameters controlling sorption and matrix diffusion on the breakthrough curves shape is included.

  19. Facial trauma.

    PubMed

    Peeters, N; Lemkens, P; Leach, R; Gemels B; Schepers, S; Lemmens, W

    Facial trauma. Patients with facial trauma must be assessed in a systematic way so as to avoid missing any injury. Severe and disfiguring facial injuries can be distracting. However, clinicians must first focus on the basics of trauma care, following the Advanced Trauma Life Support (ATLS) system of care. Maxillofacial trauma occurs in a significant number of severely injured patients. Life- and sight-threatening injuries must be excluded during the primary and secondary surveys. Special attention must be paid to sight-threatening injuries in stabilized patients through early referral to an appropriate specialist or the early initiation of emergency care treatment. The gold standard for the radiographic evaluation of facial injuries is computed tomography (CT) imaging. Nasal fractures are the most frequent isolated facial fractures. Isolated nasal fractures are principally diagnosed through history and clinical examination. Closed reduction is the most frequently performed treatment for isolated nasal fractures, with a fractured nasal septum as a predictor of failure. Ear, nose and throat surgeons, maxillofacial surgeons and ophthalmologists must all develop an adequate treatment plan for patients with complex maxillofacial trauma.

  20. Esthetic rehabilitation of complicated crown fractures utilizing rapid orthodontic extrusion and two different restoration modalities.

    PubMed

    Milardovic Ortolan, Sladana; Strujic, Mihovil; Aurer, Andrej; Viskic, Josko; Bergman, Lana; Mehulic, Ketij

    2012-01-01

    This case report describes the management of a crown-root fractured maxillary right central incisor and a crown fractured maxillary left central incisor using two different techniques. A complex procedure was designed to manage this case including orthodontic extrusion to move the fracture line above the alveolar bone and surgical recontouring of the altered gingival margin. Finally, the right incisor was restored prosthodontically. Prosthetic treatment was based on performing a post and core, and all-ceramic crown on the extruded tooth. The left, less-damaged incisor was restored directly using composite resin. The treatment resulted in good esthetics and secured periodontal health. This case report demonstrates that a multidisciplinary treatment approach is a reliable and predictable option to save a tooth. How to cite this article: Ortolan SM, Strujic M, Aurer A, Viskic J, Bergman L, Mehulic K. Esthetic Rehabilitation of Complicated Crown Fractures Utilizing Rapid Orthodontic Extrusion and Two Different Restoration Modalities. Int J Clin Pediatr Dent 2012;5(1):64-67.

  1. Aesthetic Rehabilitation of a Complicated Crown-Root Fracture of the Maxillary Incisor: Combination of Orthodontic and Implant Treatment

    PubMed Central

    de Avila, Érica Dorigatti; de Molon, Rafael Scaf; Cardoso, Mauricio de Almeida; Capelozza Filho, Leopoldino; Campos Velo, Marilia Mattar de Amoêdo; Mollo, Francisco de Assis; Borelli Barros, Luiz Antonio

    2014-01-01

    The aim of this paper is to present a complex rehabilitation, of fractured tooth, with implants in anterior region considering the orthodontics extrusion to clinical success. At 7 years old, the patient fractured the maxillary left central incisor and the dentist did a crown with the fragment. Twenty years later, the patient was referred to a dental clinic for orthodontic treatment, with the chief complaint related to an accentuated deep bite, and a professional started an orthodontic treatment. After sixteen months of orthodontic treatment, tooth 21 fractured. The treatment plan included an orthodontic extrusion of tooth 21 and implant placement. This case has been followed up and the clinical and radiographic examinations show excellence esthetic results and satisfaction of patient. The forced extrusion can be a viable treatment option in the management of crown root fracture of an anterior tooth to gain bone in a vertical direction. This case emphasizes that to achieve the esthetic result a multidisciplinary approach is necessary. PMID:24872900

  2. Association of Midfacial Fractures with Ophthalmic Injury

    PubMed Central

    Politis, Constantinus; Kluyskens, Alexandra; Dormaar, Titiaan

    2017-01-01

    The aim of this study is to evaluate the incidence of ophthalmic complications following midfacial fractures and investigate its relation to surgical or nonsurgical treatment. This article is a retrospective study, describing the spectrum and incidence of ophthalmic injury in 106 patients presenting with midfacial fractures at the Department of Oral and Maxillofacial Surgery of the University Hospitals Leuven over a period of 16 months (January 2013 to April 2014). The mean age of the patients was 45.6 years with a gender distribution of 68 men and 38 women. The main cause of trauma was road traffic accidents. Forty-one patients suffered an ophthalmic injury following the fracture. Twelve of them had a persistent ophthalmic problem. Ophthalmic examination is necessary during the initial management. The time window for preservation of sight is small and treatment should be started immediately. Development of an emergency trauma scale that includes fractures, symptoms of visual impairment, and patient history is recommended and should stimulate a multidisciplinary approach of complex cases. PMID:28523083

  3. Advances in coalbed methane reservoirs using integrated reservoir characterization and hydraulic fracturing in Karaganda coal basin, Kazakhstan

    NASA Astrophysics Data System (ADS)

    Ivakhnenko, Aleksandr; Aimukhan, Adina; Kenshimova, Aida; Mullagaliyev, Fandus; Akbarov, Erlan; Mullagaliyeva, Lylia; Kabirova, Svetlana; Almukhametov, Azamat

    2017-04-01

    Coalbed methane from Karaganda coal basin is considered to be an unconventional source of energy for the Central and Eastern parts of Kazakhstan. These regions are situated far away from the main traditional sources of oil and gas related to Precaspian petroleum basin. Coalbed methane fields in Karaganda coal basin are characterized by geological and structural complexity. Majority of production zones were characterized by high methane content and extremely low coal permeability. The coal reservoirs also contained a considerable natural system of primary, secondary, and tertiary fractures that were usually capable to accommodate passing fluid during hydraulic fracturing process. However, after closing was often observed coal formation damage including the loss of fluids, migration of fines and higher pressures required to treat formation than were expected. Unusual or less expected reservoir characteristics and values of properties of the coal reservoir might be the cause of the unusual occurred patterns in obtained fracturing, such as lithological peculiarities, rock mechanical properties and previous natural fracture systems in the coals. Based on these properties we found that during the drilling and fracturing of the coal-induced fractures have great sensitivity to complex reservoir lithology and stress profiles, as well as changes of those stresses. In order to have a successful program of hydraulic fracturing and avoid unnecessary fracturing anomalies we applied integrated reservoir characterization to monitor key parameters. In addition to logging data, core sample analysis was applied for coalbed methane reservoirs to observe dependence tiny lithological variations through the magnetic susceptibility values and their relation to permeability together with expected principal stress. The values of magnetic susceptibility were measured by the core logging sensor, which is equipped with the probe that provides volume magnetic susceptibility parameters. Permeability was measured by air permeameter. Results confirmed that there is a correspondence between the high permeability and the low magnetic susceptibility values of production zones. Importantly also were found relation of the coal envelope type between only shales coal framing or only sandstone coal framing that most likely led to different stress profiles. In addition, we briefly describe potential of other types of unconventional resources in Kazakhstan, such as shale oil, tight gas and shale gas, where this integrated approach could be useful to apply in the future.

  4. [Conventional X-Rays of Ankle Joint Fractures in Older Patients are Not Always Predictive].

    PubMed

    Jubel, A; Faymonville, C; Andermahr, J; Boxberg, S; Schiffer, G

    2017-02-01

    Background: Ankle fractures are extremely common in the elderly, with an incidence of up to 39 fractures per 100,000 persons per year. We found a discrepancy between intraoperative findings and preoperative X-ray findings. It was suggested that many relevant lesions of the ankle joint in the elderly cannot be detected with plain X-rays. Methods: Complete data sets and preoperative X-rays of 84 patients aged above 60 years with ankle fractures were analysed retrospectively. There were 59 women and 25 men, with a mean age of 69.9 years. Operation reports and preoperative X-rays were analysed with respect to four relevant lesions: multifragmentary fracture pattern of the lateral malleolus, involvement of the medial malleolus, posterior malleolar fractures and bony avulsion of anterior syndesmosis. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy and prevalence were calculated. Results: The prevalence of specific ankle lesions in the analyzed cohort was 24 % for the multifragmentary fracture pattern of the lateral malleolus, 38 % for fractures of the medial malleolus, 25 % for posterior malleolar fractures and 22.6 % for bony avulsions of the anterior syndesmosis. Multifragmentary fracture patterns of the lateral malleolus (sensitivity 0 %) and bony avulsions of the anterior syndesmosis (sensitivity 5 %) could not be detected in plain X-rays of the ankle joint at all. Fractures of the medial malleolus and involvement of the dorsal tibial facet were detected with a sensitivity of 96.8 % and 76.2 %, respectively, and specificity of 100 % in both cases. Conclusions: This study confirms that complex fracture patterns, such as multifragmentary involvement of the lateral malleolus, additional fracture of the medial malleolus, involvement of the dorsal tibial facet or bony avulsion of the anterior syndesmosis are common in ankle fractures of the elderly. Therefore, CT scans should be routinely considered for primary diagnosis, in addition to plain X-rays. Georg Thieme Verlag KG Stuttgart · New York.

  5. A quasi steady state method for solving transient Darcy flow in complex 3D fractured networks accounting for matrix to fracture flow

    NASA Astrophysics Data System (ADS)

    Nœtinger, B.

    2015-02-01

    Modeling natural Discrete Fracture Networks (DFN) receives more and more attention in applied geosciences, from oil and gas industry, to geothermal recovery and aquifer management. The fractures may be either natural, or artificial in case of well stimulation. Accounting for the flow inside the fracture network, and accounting for the transfers between the matrix and the fractures, with the same level of accuracy is an important issue for calibrating the well architecture and for setting up optimal resources recovery strategies. Recently, we proposed an original method allowing to model transient pressure diffusion in the fracture network only [1]. The matrix was assumed to be impervious. A systematic approximation scheme was built, allowing to model the initial DFN by a set of N unknowns located at each identified intersection between fractures. The higher N, the higher the accuracy of the model. The main assumption was using a quasi steady state hypothesis, that states that the characteristic diffusion time over one single fracture is negligible compared with the characteristic time of the macroscopic problem, e.g. change of boundary conditions. In that context, the lowest order approximation N = 1 has the form of solving a transient problem in a resistor/capacitor network, a so-called pipe network. Its topology is the same as the network of geometrical intersections between fractures. In this paper, we generalize this approach in order to account for fluxes from matrix to fractures. The quasi steady state hypothesis at the fracture level is still kept. Then, we show that in the case of well separated time scales between matrix and fractures, the preceding model needs only to be slightly modified in order to incorporate these fluxes. The additional knowledge of the so-called matrix to fracture transfer function allows to modify the mass matrix that becomes a time convolution operator. This is reminiscent of existing space averaged transient dual porosity models.

  6. Predictors of the postoperative range of finger motion for comminuted periarticular metacarpal and phalangeal fractures treated with a titanium plate.

    PubMed

    Shimizu, Takamasa; Omokawa, Shohei; Akahane, Manabu; Murata, Keiichi; Nakano, Kenichi; Kawamura, Kenji; Tanaka, Yasuhito

    2012-06-01

    Plate and screw fixation was introduced for complex fractures of the hand. Several risk factors for a poor functional outcome have been identified, but there is a paucity of evidence regarding predictors of finger stiffness in difficult hand fractures. The purpose of this prospective cohort study was to identify independent prognostic factors of the postoperative total active motion (%TAM) in the treatment of metacarpal and phalangeal fractures. Seventy-two patients (62 males, 10 females; 37±15 years) with periarticular fractures involving metaphyseal comminution and displacement were evaluated at a minimum of 1 year following surgery. There were 49 phalangeal bone fractures, 30 intra-articular fractures and 20 associated soft-tissue injuries. The locations of plate placement were lateral in 42 patients and dorsal in 30. The mean duration from injury to surgery was 7.6 days (range, 0-40 days). There were eight examined variables related to patient characteristics (age, gender and hand dominance), fracture characteristics (fracture location, joint involvement and associated soft-tissue injury) and surgical variables (location of plate placement and duration from injury to surgery). Univariate and multivariate linear regression analysis were used to identify the degree to which variables affect %TAM at the final follow-up. Univariate analysis indicated moderate correlations of %TAM with fracture location, associated soft-tissue injury and age. Multiple linear regression modelling including fracture location, age and associated soft-tissue injury resulted in formulae that could account for 46.3% of the variability in %TAM: fracture location (β=-0.388, p<0.001), age (β=-0.339, p<0.001) and associated soft-tissue injury (β=-0.296, p=0.002). Phalangeal fracture, increasing age and associated soft-tissue injury were important risk factors to identify the postoperative %TAM in the treatment of comminuted periarticular metacarpal or phalangeal fracture with a titanium plate. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Propagation of Gaussian wave packets in complex media and application to fracture characterization

    NASA Astrophysics Data System (ADS)

    Ding, Yinshuai; Zheng, Yingcai; Zhou, Hua-Wei; Howell, Michael; Hu, Hao; Zhang, Yu

    2017-08-01

    Knowledge of the subsurface fracture networks is critical in probing the tectonic stress states and flow of fluids in reservoirs containing fractures. We propose to characterize fractures using scattered seismic data, based on the theory of local plane-wave multiple scattering in a fractured medium. We construct a localized directional wave packet using point sources on the surface and propagate it toward the targeted subsurface fractures. The wave packet behaves as a local plane wave when interacting with the fractures. The interaction produces multiple scattering of the wave packet that eventually travels up to the surface receivers. The propagation direction and amplitude of the multiply scattered wave can be used to characterize fracture density, orientation and compliance. Two key aspects in this characterization process are the spatial localization and directionality of the wave packet. Here we first show the physical behaviour of a new localized wave, known as the Gaussian Wave Packet (GWP), by examining its analytical solution originally formulated for a homogenous medium. We then use a numerical finite-difference time-domain (FDTD) method to study its propagation behaviour in heterogeneous media. We find that a GWP can still be localized and directional in space even over a large propagation distance in heterogeneous media. We then propose a method to decompose the recorded seismic wavefield into GWPs based on the reverse-time concept. This method enables us to create a virtually recorded seismic data using field shot gathers, as if the source were an incident GWP. Finally, we demonstrate the feasibility of using GWPs for fracture characterization using three numerical examples. For a medium containing fractures, we can reliably invert for the local parameters of multiple fracture sets. Differing from conventional seismic imaging such as migration methods, our fracture characterization method is less sensitive to errors in the background velocity model. For a layered medium containing fractures, our method can correctly recover the fracture density even with an inaccurate velocity model.

  8. Charon Complexity

    NASA Image and Video Library

    2015-09-10

    This image of Pluto's largest moon Charon, taken by NASA's New Horizons spacecraft 10 hours before its closest approach to Pluto on July 14, 2015 from a distance of 290,000 miles (470,000 kilometers), is a recently downlinked, much higher quality version of a Charon image released on July 15. Charon, which is 750 miles (1,200 kilometers) in diameter, displays a surprisingly complex geological history, including tectonic fracturing; relatively smooth, fractured plains in the lower right; several enigmatic mountains surrounded by sunken terrain features on the right side; and heavily cratered regions in the center and upper left portion of the disk. There are also complex reflectivity patterns on Charon's surface, including bright and dark crater rays, and the conspicuous dark north polar region at the top of the image. The smallest visible features are 2.9 miles 4.6 kilometers) in size. http://photojournal.jpl.nasa.gov/catalog/PIA19932

  9. The use of interlocking prostheses for both temporary and definitive management of infected periprosthetic femoral fractures.

    PubMed

    Konan, Sujith; Rayan, Faizal; Manketelow, Andrew R J; Haddad, Fares S

    2011-12-01

    Infected periprosthetic fractures around total hip arthroplasties are an extremely challenging problem. We describe our experience of managing infected periprosthetic femoral fractures using interlocking long-stem femoral prostheses either as temporary functional spacers or as definitive implants. The Cannulock (Orthodesign, Christchurch, United Kingdom) uncoated stem was used in 12 cases, and the Kent hip prosthesis (Biomet Merck, Bridgend, United Kingdom), in 5 cases. Satisfactory outcome was noted in all cases, and in 11 cases, revision to a definitive stem has been undertaken after successful control of infection and fracture union. The use of interlocking stems offers a relatively appealing solution for a complex problem and avoids the complications that would be associated with resection of the entire femur or the use of large quantities of bone cement. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Igneous intrusion models for floor fracturing in lunar craters

    NASA Technical Reports Server (NTRS)

    Wichman, R. W.; Schultz, P. H.

    1991-01-01

    Lunar floor-fractured craters are primarily located near the maria and frequently contain ponded mare units and dark mantling deposits. Fracturing is confined to the crater interior, often producing a moat-like feature near the floor edge, and crater depth is commonly reduced by uplift of the crater floor. Although viscous relaxation of crater topography can produce such uplift, the close association of modification with surface volcanism supports a model linking floor fracture to crater-centered igneous intrusions. The consequences of two intrusion models for the lunar interior are quantitatively explored. The first model is based on terrestrial laccoliths and describes a shallow intrusion beneath the crater. The second model is based on cone sheet complexes where surface deformation results from a deeper magma chamber. Both models, their fit to observed crater modifications and possible implications for local volcanism are described.

  11. Numerical examination of the factors controlling DNAPL migration through a single fracture.

    PubMed

    Reynolds, D A; Kueper, B H

    2002-01-01

    The migration of five dense nonaqueous phase liquids (DNAPLs) through a single fracture in a clay aquitard was numerically simulated with the use of a compositional simulator. The effects of fracture aperture, fracture dip, matrix porosity, and matrix organic carbon content on the migration of chlorobenzene, 1,2-dichloroethylene, trichloroethylene, tetra-chloroethylene, and 1,2-dibromoethane were examined. Boundary conditions were chosen such that DNAPL entry into the system was allowed to vary according to the stresses applied. The aperture is the most important factor of those studied controlling the migration rate of DNAPL through a single fracture embedded in a clay matrix. Loss of mass to the matrix through diffusion does not significantly retard the migration rate of the DNAPL, particularly in larger aperture fractures (e.g., 50 microm). With time, the ratio of diffusive loss to the matrix to DNAPL flux into the fracture approaches an asymptotic value lower than unity. The implication is that matrix diffusion cannot arrest the migration of DNAPL in a single fracture. The complex relationships between density, viscosity, and solubility that, to some extent, govern the migration of DNAPL through these systems prevent accurate predictions without the use of numerical models. The contamination potential of the migrating DNAPL is significantly increased through the transfer of mass to the matrix. The occurrence of opposite concentration gradients within the matrix can cause dissolved phase contamination to exist in the system for more than 1000 years after the DNAPL has been completely removed from the fracture.

  12. Pelvic fracture in the patient with multiple injuries: factors and lesions associated with mortality.

    PubMed

    Martínez, Fernando; Alegret, Núria; Carol, Federico; Laso, M Jesús; Zancajo, Juanjo; García, Esteban; Ros, Vanesa

    2018-01-01

    The main objective of this study was to identify demographic, clinical, analytical factors or injuries associated with 30-day mortality in patients with pelvic fractures. Prospective observational study of patients with multiple injuries including pelvic fractures between January 2009 and January 2017. We recorded demographic, clinical, and laboratory data on arrival at the emergency department; type of pelvic fracture; treatments; associated lesions; and 30-day mortality. Univariable and multivariable models were used to analyze the data. A total of 2061 multiple-injury patients were attended; 118 had pelvic fractures. Fifteen of the patients with pelvic fractures (12.7%) died within 30 days. Arterial blood pressure on admission was less than 90 mm Hg in 23.7%, heart rate was over 100 beats per minute in 41.52%, lactic acid level was 20 mg/dL or higher in 67.6%, and base excess of -6 or less was recorded for 26.3%. The mean Injury Severity Score was 20 points. Angiographic embolization was required in 80.6% and preperitoneal packing in 3.4%. The main associated lesions were rib fractures (35.6%), hemo-pneumothorax (31.3%), spinal injuries (35.6%), and head injuries (30%). The 6 independent variables associated with risk of death in multiple-injury patients with pelvic fractures are age, female sex, complex fractures (Tile type C), lactic acid level of 20 mg/dL or more, base excess of -6 or less, and bowel perforation.

  13. Basic concepts regarding fracture healing and the current options and future directions in managing bone fractures.

    PubMed

    Bigham-Sadegh, Amin; Oryan, Ahmad

    2015-06-01

    Fracture healing is a complex physiological process, which involves a well-orchestrated series of biological events. Repair of large bone defects resulting from trauma, tumours, osteitis, delayed unions, non-unions, osteotomies, arthrodesis and multifragmentary fractures is a current challenge of surgeons and investigators. Different therapeutic modalities have been developed to enhance the healing response and fill the bone defects. Different types of growth factors, stem cells, natural grafts (autografts, allografts or xenografts) and biologic- and synthetic-based tissue-engineered scaffolds are some of the examples. Nevertheless, these organic and synthetic materials and therapeutic agents have some significant limitations, and there are still no well-approved treatment modalities to meet all the expected requirements. Bone tissue engineering is a newer option than the traditional grafts and may overcome many limitations of the bone graft. To select an appropriate treatment strategy in achieving a successful and secure healing, more information concerning injuries of bones, their healing process and knowledge of the factors involved are required. The main goals of this work are to present different treatment modalities of the fractured bones and to explain how fractures normally heal and what factors interfere with fracture healing. This study provides an overview of the processes of fracture healing and discusses the current therapeutic strategies that have been claimed to be effective in accelerating fracture healing. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  14. Intravenous zoledronic acid for the treatment of osteoporosis: The evidence of its therapeutic effect

    PubMed Central

    Lewiecki, E Michael

    2010-01-01

    Introduction: Osteoporosis is a disease characterized by low bone mineral density and poor bone quality resulting in reduced bone strength and increased risk of fracture. Oral bisphosphonates, first-line therapy for most patients with osteoporosis, are associated with suboptimal adherence to therapy due to factors that include a complex dosing regimen and gastrointestinal intolerance in some patients. Intravenous bisphosphonates address these limitations through infrequent injectable dosing that assures 100% bioavailability. Intravenous zoledronic acid is the newest bisphosphonate to be approved for the treatment of osteoporosis. Aims: This review assesses the evidence for the therapeutic effects of intravenous zoledronic acid for the treatment of osteoporosis. Evidence review: Zoledronic acid 5 mg administered as an annual 15-min intravenous infusion has been shown to reduce the risk of vertebral fractures, hip fractures, and other fractures in a three-year randomized, double-blind, placebo-controlled trial in women with postmenopausal osteoporosis. In a randomized, double-blind, placebo-controlled trial in women and men with a recent surgical repair of low-trauma hip fracture, it reduced the risk of new clinical fractures and improved survival. In both studies, zoledronic acid was associated with a good safety profile and was generally well tolerated. Zoledronic acid has the potential to improve clinical outcomes by reducing the risk of fracture in patients with osteoporosis. Clinical value: Intravenous zoledronic acid 5 mg every 12 months reduces fracture risk in women with postmenopausal osteoporosis and in women and men with recent low-trauma hip fracture. PMID:20694061

  15. A simplified fracture network model for studying the efficiency of a single well semi open loop heat exchanger in fractured crystalline rock

    NASA Astrophysics Data System (ADS)

    de La Bernardie, Jérôme; de Dreuzy, Jean-Raynald; Bour, Olivier; Thierion, Charlotte; Ausseur, Jean-Yves; Lesuer, Hervé; Le Borgne, Tanguy

    2016-04-01

    Geothermal energy is a renewable energy source particularly attractive due to associated low greenhouse gas emission rates. Crystalline rocks are in general considered of poor interest for geothermal applications at shallow depths (< 100m), because of the low permeability of the medium. In some cases, fractures may enhance permeability, but thermal energy storage at these shallow depths is still remaining very challenging because of the complexity of fractured media. The purpose of this study is to test the possibility of efficient thermal energy storage in shallow fractured rocks with a single well semi open loop heat exchanger (standing column well). For doing so, a simplified numerical model of fractured media is considered with few fractures. Here we present the different steps for building the model and for achieving the sensitivity analysis. First, an analytical and dimensional study on the equations has been achieved to highlight the main parameters that control the optimization of the system. In a second step, multiphysics software COMSOL was used to achieve numerical simulations in a very simplified model of fractured media. The objective was to test the efficiency of such a system to store and recover thermal energy depending on i) the few parameters controlling fracture network geometry (size and number of fractures) and ii) the frequency of cycles used to store and recover thermal energy. The results have then been compared to reference shallow geothermal systems already set up for porous media. Through this study, relationships between structure, heat exchanges and storage may be highlighted.

  16. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures.

    PubMed

    Ma, Ching-Hou; Tu, Yuan-Kun; Yeh, Jih-Hsi; Yang, Shih-Chieh; Wu, Chin-Hsien

    2011-09-01

    The tibial segmental fractures usually follow high-energy trauma and are often associated with many complications. We designed a two-stage protocol for these complex injuries. The aim of this study was to assess the outcome of tibial segmental fractures treated according to this protocol. A prospective series of 25 consecutive segmental tibial fractures were treated using a two-stage procedure. In the first stage, a low-profile locking plate was applied as an external fixator to temporarily immobilize the fractures after anatomic reduction had been achieved followed by soft-tissue reconstruction. The second stage involved definitive internal fixation with a locking plate using a minimally invasive percutaneous plate osteosynthesis technique. The median follow-up was 32 months (range, 20-44 months). All fractures achieved union. The median time for the proximal fracture union was 23 weeks (range, 12-30 weeks) and that for distal fracture union was 27 weeks (range, 12-46 weeks; p = 0.08). Functional results were excellent in 21 patients and good in 4 patients. There were three cases of delayed union of distal fracture. Valgus malunion >5 degrees occurred in two patients, and length discrepancy >1 cm was observed in two patients. Pin tract infection occurred in three patients. Use of the two-stage procedure for treatment of segmental tibial fractures is recommended. Surgeons can achieve good reduction with stable temporary fixation, soft-tissue reconstruction, ease of subsequent definitive fixation, and high union rates. Our patients obtained excellent knee and ankle joint motion, good functional outcomes, and a comfortable clinical course.

  17. Reverse Shoulder Arthroplasty for the Treatment of 3 and 4- Part Fractures of the Humeral Head in the Elderly

    PubMed Central

    Gigis, Ioannis; Nenopoulos, Alexandros; Giannekas, Dimitrios; Heikenfeld, Roderich; Beslikas, Theodoros; Hatzokos, Ippokratis

    2017-01-01

    Background: Proximal humeral fractures in elderly patients present with severe comminution and osteoporotic bone quality. Reverse shoulder arthroplasty has lately been proven beneficial in treating patients with complex proximal humeral fractures. The above technique is recommended and has better results in elderly than in younger individuals. Methods: We performed a literature search in the databases Pubmed, Medline, EMBASE and Cochrane Library for published articles between 1970 and 2016 using the terms: proximal humerus fractures and reverse shoulder arthroplasty. Results: Significant benefits with the use of reverse prosthesis, especially in patients older than 70 years with a proximal humeral fracture, include reduced rehabilitation time as well as conservation of a fixed fulcrum for deltoid action in case of rotator cuff failure. Compared with hemiarthroplasty and internal fixation, reverse prosthesis may be particularly useful and give superior outcomes in older patients, due to comminuted fractures in osteopenic bones. However, significant disadvantages of this technique are potential complications and a demanding learning curve.Therefore, trained surgeons should follow specific indications when applying the particular treatment of proximal humeral fractures and be familiar with the surgical technique. Conclusion: Although long-term results and randomized studies for reverse prosthesis are lacking, short and mid- term outcomes have given promising results encouraging more shoulder surgeons to use this type of prosthesis in proximal humeral fractures. PMID:28400879

  18. Identification of a progenitor cell population destined to form fracture fibrocartilage callus in Dickkopf-related protein 3-green fluorescent protein reporter mice.

    PubMed

    Mori, Yu; Adams, Douglas; Hagiwara, Yusuke; Yoshida, Ryu; Kamimura, Masayuki; Itoi, Eiji; Rowe, David W

    2016-11-01

    Fracture healing is a complex biological process involving the proliferation of mesenchymal progenitor cells, and chondrogenic, osteogenic, and angiogenic differentiation. The mechanisms underlying the proliferation and differentiation of mesenchymal progenitor cells remain unclear. Here, we demonstrate Dickkopf-related protein 3 (Dkk3) expression in periosteal cells using Dkk3-green fluorescent protein reporter mice. We found that proliferation of mesenchymal progenitor cells began in the periosteum, involving Dkk3-positive cell proliferation near the fracture site. In addition, Dkk3 was expressed in fibrocartilage cells together with smooth muscle α-actin and Col3.6 in the early phase of fracture healing as a cell marker of fibrocartilage cells. Dkk3 was not expressed in mature chondrogenic cells or osteogenic cells. Transient expression of Dkk3 disappeared in the late phase of fracture healing, except in the superficial periosteal area of fracture callus. The Dkk3 expression pattern differed in newly formed type IV collagen positive blood vessels and the related avascular tissue. This is the first report that shows Dkk3 expression in the periosteum at a resting state and in fibrocartilage cells during the fracture healing process, which was associated with smooth muscle α-actin and Col3.6 expression in mesenchymal progenitor cells. These fluorescent mesenchymal lineage cells may be useful for future studies to better understand fracture healing.

  19. Influence of fracture geometry on bone healing under locking plate fixations: A comparison between oblique and transverse tibial fractures.

    PubMed

    Miramini, Saeed; Zhang, Lihai; Richardson, Martin; Mendis, Priyan; Ebeling, Peter R

    2016-10-01

    Mechano-regulation plays a crucial role in bone healing and involves complex cellular events. In this study, we investigate the change of mechanical microenvironment of stem cells within early fracture callus as a result of the change of fracture obliquity, gap size and fixation configuration using mechanical testing in conjunction with computational modelling. The research outcomes show that angle of obliquity (θ) has significant effects on interfragmentary movement (IFM) which influences mechanical microenvironment of the callus cells. Axial IFM at near cortex of fracture decreases with θ, while shear IFM significantly increases with θ. While a large θ can increase shear IFM by four-fold compared to transverse fracture, it also result in the tension-stress effect at near cortex of fracture callus. In addition, mechanical stimuli for cell differentiation within the callus are found to be strongly negatively correlated to angle of obliquity and gap size. It is also shown that a relatively flexible fixation could enhance callus formation in presence of a large gap but could lead to excessive callus strain and interstitial fluid flow when a small transverse fracture gap is present. In conclusion, there appears to be an optimal fixation configuration for a given angle of obliquity and gap size. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. [Endoprostheses in geriatric traumatology].

    PubMed

    Buecking, B; Eschbach, D; Bliemel, C; Knobe, M; Aigner, R; Ruchholtz, S

    2017-01-01

    Geriatric traumatology is increasing in importance due to the demographic transition. In cases of fractures close to large joints it is questionable whether primary joint replacement is advantageous compared to joint-preserving internal fixation. The aim of this study was to describe the importance of prosthetic joint replacement in the treatment of geriatric patients suffering from frequent periarticular fractures in comparison to osteosynthetic joint reconstruction and conservative methods. A selective search of the literature was carried out to identify studies and recommendations concerned with primary arthroplasty of fractures in the region of the various joints (hip, shoulder, elbow and knee). The importance of primary arthroplasty in geriatric traumatology differs greatly between the various joints. Implantation of a prosthesis has now become the gold standard for displaced fractures of the femoral neck. In addition, reverse shoulder arthroplasty has become an established alternative option to osteosynthesis in the treatment of complex proximal humeral fractures. Due to a lack of large studies definitive recommendations cannot yet be given for fractures around the elbow and the knee. Nowadays, joint replacement for these fractures is recommended only if reconstruction of the joint surface is not possible. The importance of primary joint replacement for geriatric fractures will probably increase in the future. Further studies with larger patient numbers must be conducted to achieve more confidence in decision making between joint replacement and internal fixation especially for shoulder, elbow and knee joints.

  1. Fatal falls involving stairs: an anthropological analysis of skeletal trauma.

    PubMed

    Rowbotham, Samantha K; Blau, Soren; Hislop-Jambrich, Jacqueline; Francis, Victoria

    2018-06-01

    The skeletal blunt force trauma resulting from fatal falls involving stairs is complex. There are countless ways an individual may fall when stairs are involved, and thus a variety of ways the skeleton may fracture. Therefore anecdotally, it may be said that there is no specific skeletal trauma characteristic of this fall type. In order to scientifically investigate this anecdotal understanding, this study provides a detailed investigation of the skeletal fracture patterns and morphologies resulting from fatal falls involving stairs. Skeletal trauma was analyzed using the full-body postmortem computed tomography scans of 57 individuals who died from a fall involving stairs. Trauma was examined in the context of the variables that potentially influence how an individual falls (i.e. sex, age, body mass index, number of stairs involved, psychoactive drugs, pre-existing conditions, landing surface and manner of the fall) using logistic regression. Skeletal trauma primarily occurred in the axial skeleton. An analysis of fracture patterns showed the cranial base was less likely to fracture in younger individuals and the cervical vertebrae were more likely to fracture in falls that involved more than half a flight of stairs. A total of 56 fracture morphologies were identified. Of these, diastatic fractures were less likely to occur in older individuals. Findings indicate that there are skeletal fracture patterns and morphologies characteristic of a fatal fall involving stairs.

  2. Infrared monitoring of hydrothermal echanges occurring in a fracture

    NASA Astrophysics Data System (ADS)

    Neuville, Amélie; Flekkøy, Eirik; Galland, Olivier; Gundersen, Olav; Jørgen Måløy, Knut

    2014-05-01

    We aim to characterize the heat exchange that occurs when water flows through a fracture at a different temperature from that of the surrounding rock. This happens during many man-made or natural processes. For instance, injection of water in the context of geothermal power plants or sudden mechanical movements (e.g. rockfalls, landslides, earthquakes) that transport water. It is presently challenging to estimate the heat transfer and temperature inside a fractured medium where water is flowing, despite various numerical models which have been proposed [Neuville et al, 2010, 2013; Kolditz et Clauser, 1998; Heuer, 1991]. The difficulties arise from the complexity of the fracture network, the fracture topography, as well as complex hydraulic flow (e.g. recirculation) and heat exchanges. As a consequence, various hypotheses were made in the models. More experimental data are required in order to calibrate these models, validate or refute the hypotheses. Our work aims to provide temperature data at the fracture scale, in an experiment where the pressure gradient an fracture topography are controlled, with slow hydraulic flow. This required to develop a setup from scratch. An infrared camera and thermistors are used to monitor the temperature in space and time. Water is injected through a partly natural rough fracture with impermeable walls. The bottom part of the fracture is a larvikite stone with a rough surface (presumably this surface was obtained from mode I fracturing), and the top part is a layer which is transparent in the infrared range. As a consequence the infrared camera is expected to measure the temperature at the interface between this transparent layer and the water. The topography of the surface of the rock was reconstituted using a photogrammetry software [MicMac, IGN], and compared to measurements made with a mechanical profiler. Using this geometry we carefully localize the temperature observations (infrared camera and thermistors) and correlate the temperature variations with the topography. Preliminary comparisons with simulations from a coupled lattice Boltzmann method that solves both the complete Navier-Stokes and advection-diffusion equations in three-dimensions are also presented. N. Heuer, T. Küpper and D. Windelberg, Mathematical model of a Hot Dry Rock system, Geophys. J. Int. 105, 659-664 (1991). O. Kolditz and C. Clauser, Numerical simulation of flow and heat transefer in fractured cristalline rocks: application to the hot dry rock site in Rosemanowes (U.K.), Geothermics, 27, 1, p 1-23, (1998). MicMac, IGN: sofware developed by the French Institut Géographique National (IGN) A. Neuville, R. Toussaint, and J. Schmittbuhl, Hydro-thermal flows in a self-affine rough fracture, Phys. Rev. E, 82, 036,317, (2010). A. Neuville, E.G. Flekkøy, R. Toussaint, Influence of asperities on fluid and thermal flow in a fracture: a coupled Lattice Boltzmann study. Journal of Geophysical Research, 118, 7, 3394-3407, (2013).

  3. The floating shoulder.

    PubMed

    Owens, B D; Goss, T P

    2006-11-01

    The floating shoulder is defined as ipsilateral fractures of the midshaft of the clavicle and the neck of the glenoid. This rare injury can be difficult to manage without a thorough understanding of the complex anatomy of the shoulder girdle. Surgical intervention needs to be considered for all of these injuries. While acceptable results can be expected with non-operative management of minimally-displaced fractures, displacement at one or both sites is best managed with surgical reduction and fixation.

  4. Application of 3D printed customized external fixator in fracture reduction.

    PubMed

    Qiao, Feng; Li, Dichen; Jin, Zhongmin; Gao, Yongchang; Zhou, Tao; He, Jinlong; Cheng, Li

    2015-01-01

    Long bone fracture is common in traumatic osteopathic patients. Good reduction is beneficial for bone healing, preventing the complications such as delayed union, nonunion, malunion, but is hard to achieve. Repeated attempts during the surgery would increase the operation time, cause new damage to the fracture site and excessive exposure to radiation. Robotic and navigation techniques can help improve the reduction accuracy, however, the high cost and complexity of operation have limited their clinical application. We combined 3D printing with computer-assisted reduction technique to develop a customised external fixator with the function of fracture reduction. The original CT data obtained by scanning the fracture was imported to computer for reconstructing and reducing the 3D image of the fracture, based on which the external fixator (named as Q-Fixator) was designed and then fabricated by 3D printing techniques. The fracture reduction and fixation was achieved by connecting the pins inserted in the bones with the customised Q-Fixator. Experiments were conducted on three fracture models to demonstrate the reduction results. Good reduction results were obtained on all three fractured bone models, with an average rotation of 1.21°(± 0.24), angulation of 1.84°(± 0.28), and lateral displacement of 2.22 mm(± 0.62). A novel customised external fixator for long bone fracture reduction was readily developed using 3D printing technique. The customised external fixator had the advantages of easy manipulation, accurate reduction, minimally invasion and experience-independence. Future application of the customised external fixator can be extended to include the fixation function with stress adjustment and potentially optimise the fracture healing process. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Integrated workflow for characterizing and modeling fracture network in unconventional reservoirs using microseismic data

    NASA Astrophysics Data System (ADS)

    Ayatollahy Tafti, Tayeb

    We develop a new method for integrating information and data from different sources. We also construct a comprehensive workflow for characterizing and modeling a fracture network in unconventional reservoirs, using microseismic data. The methodology is based on combination of several mathematical and artificial intelligent techniques, including geostatistics, fractal analysis, fuzzy logic, and neural networks. The study contributes to scholarly knowledge base on the characterization and modeling fractured reservoirs in several ways; including a versatile workflow with a novel objective functions. Some the characteristics of the methods are listed below: 1. The new method is an effective fracture characterization procedure estimates different fracture properties. Unlike the existing methods, the new approach is not dependent on the location of events. It is able to integrate all multi-scaled and diverse fracture information from different methodologies. 2. It offers an improved procedure to create compressional and shear velocity models as a preamble for delineating anomalies and map structures of interest and to correlate velocity anomalies with fracture swarms and other reservoir properties of interest. 3. It offers an effective way to obtain the fractal dimension of microseismic events and identify the pattern complexity, connectivity, and mechanism of the created fracture network. 4. It offers an innovative method for monitoring the fracture movement in different stages of stimulation that can be used to optimize the process. 5. Our newly developed MDFN approach allows to create a discrete fracture network model using only microseismic data with potential cost reduction. It also imposes fractal dimension as a constraint on other fracture modeling approaches, which increases the visual similarity between the modeled networks and the real network over the simulated volume.

  6. Maxillofacial fracture experiences: a review of 152 cases.

    PubMed

    Aydin, Osman Enver; Tan, Onder; Algan, Said; Kuduban, Selma Denktas; Barin, Ensar Zafer; Cinal, Hakan; Sarici, Murat; Avsar, Umit

    2012-12-01

    The fractures of facial structures lead to great morbidity. Cross-sectional studies are needed to evaluate the current state of maxillofacial traumas. Thus, this study aims to evaluate these experiences and to compare these results with the current literature. The medical records of the maxillofacial fracture cases hospitalized between January 2004 and November 2011 were examined. The age, sex, etiology, fracture localization and treatment method for each case were documented. The affected facial bones were grouped as mandible, maxilla, zygoma, naso-orbitoethmoid complex (NOEC) and blow-out. Nasal fractures were excluded. The cases were assigned to 3 groups with respect to age (below 16, above 65 and between 17 and 64). The chi Square test was used to assess the significance of the difference in mandibular fracture rates in the pediatric population compared to others. The total number of cases was 152. The total number of fractures was 185. Of the 152 cases, 117 were male and 35 were female. The average age was 31.4 (±18.3), ranging between 2 and 81. Thirty-one cases were 16 years old or less. Nine cases were 65 years old or more. Mandibular and zygomatic fractures were the most prevalent fractures in the adult group. Mandibular fractures were significantly more common in the pediatric age group compared to rest of the population (X(2), p<0.05). Traffic accidents were the most common etiological factor, with a 55.3% ratio. Open reduction and internal fixation was the most frequently conducted treatment modality in all age groups. Retrospective studies are important for the projection of future prospects. In summary, our results indicate that pediatric fractures are mostly in the lower face and usually affect the condylar region, which is consistent with the literature.

  7. Biochemical Predictors of Low Bone Mineral Density and Fracture Susceptibility in Maltese Postmenopausal Women.

    PubMed

    Formosa, Melissa M; Xuereb-Anastasi, Angela

    2016-01-01

    Osteoporosis and fractures are complex conditions influenced by an interplay of genetic and environmental factors. The aim of the study was to investigate three biochemical parameters including total serum calcium, total serum alkaline phosphatase (sALP) and albumin in relation to bone mineral density (BMD) at the lumbar spine and femoral neck (FN), and with all-type of low-trauma fractures in Maltese postmenopausal women. Levels were also correlated with age and physical activity. A case-control study of 1045 women was performed. Women who suffered a fracture were classified as cases whereas women without a fracture history were included as controls subdivided into normal, osteopenic, or osteoporotic according to their BMD measurements. Blood specimens were collected following good standard practice and testing was performed by spectrophotometry. Calcium and sALP levels were weakly correlated with FN BMD levels (calcium: r = -0.111, p = 0.002; sALP: r = 0.089, p = 0.013). Fracture cases had the lowest serum levels of calcium, sALP and albumin relative to all other control groups, which decreased with increasing age, possibly increasing fracture risk. Biochemical levels were lowest in women who sustained a hip fracture and more than one fracture. Biochemical parameters decreased with reduced physical activity; however, this was most evident for fracture cases. Reduced physical activity was associated with lower BMD levels at the hip, and to a lower extent at the spine. In conclusion, results suggest that levels of serum calcium and albumin could be indicative of fracture risk, whereas calcium levels and to lower extent sALP levels could be indicators of hip BMD.

  8. Using a Team Approach to Meet Complex Family Needs

    ERIC Educational Resources Information Center

    Njorge, Wanijiku F. M.

    2011-01-01

    Mental health clinicians who work with families with infants and toddlers often face complex challenges that require collaboration among many professionals and disciplines. A team approach to addressing infant mental health is critical to successful intervention. In this articles, a fractured family dealing with interpersonal violence and maternal…

  9. Hidden contributions of the enamel rods on the fracture resistance of human teeth.

    PubMed

    Yahyazadehfar, M; Bajaj, Devendra; Arola, Dwayne D

    2013-01-01

    The enamel of human teeth is generally regarded as a brittle material with low fracture toughness. Consequently, the contributions of this tissue in resisting tooth fracture and the importance of its complex microstructure have been largely overlooked. In this study an experimental evaluation of the crack growth resistance of human enamel was conducted to characterize the role of rod (i.e. prism) orientation and degree of decussation on the fracture behavior of this tissue. Incremental crack growth was achieved in-plane, with the rods in directions longitudinal or transverse to their axes. Results showed that the fracture resistance of enamel is both inhomogeneous and spatially anisotropic. Cracks extending transverse to the rods in the outer enamel undergo a lower rise in toughness with extension, and achieve significantly lower fracture resistance than in the longitudinal direction. Though cracks initiating at the surface of teeth may begin extension towards the dentin-enamel junction, they are deflected by the decussated rods and continue growth about the tooth's periphery, transverse to the rods in the outer enamel. This process facilitates dissipation of fracture energy and averts cracks from extending towards the dentin and vital pulp. Copyright © 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  10. Surgical management of coracoid fractures: technical tricks and clinical experience.

    PubMed

    Hill, Brian W; Jacobson, Aaron R; Anavian, Jack; Cole, Peter A

    2014-05-01

    The coracoid process plays a pivotal role in the foundation of the coracoacromial arch and in cases of displaced fractures; surgical management may be warranted to avoid functional compromise or impingement. A direct approach through Langer's lines allows for easy exposure and direct visualization for an anatomic reduction of simple fractures through the shaft or base of the coracoid. An anterior approach for fractures that extend into the superior glenoid fossa allows for direct exposure to obtain an anatomic articular reduction and indirect reduction of the coracoid fracture. In cases where a complex glenoid or scapula neck/body fracture is being addressed simultaneously either a posterior Judet approach can be used with an indirect reduction method or a separate anterior approach must be combined to address it if not in continuity with the superior scapular segment. Implant selection, primarily interfragmentary screws or a buttress plate, should be based on the size of the fragment, the degree of comminution, and the degree of articular involvement to ensure adequate stabilization. The purpose of this manuscript was to describe a stepwise approach to the surgical management of displaced coracoid fractures, describe surgical tips and techniques, and to present the clinical outcomes in 22 patients after surgical treatment with this approach.

  11. Injuries of the Medial Clavicle: A Cohort Analysis in a Level-I-Trauma-Center. Concomitant Injuries. Management. Classification.

    PubMed

    Bakir, Mustafa Sinan; Merschin, David; Unterkofler, Jan; Guembel, Denis; Langenbach, Andreas; Ekkernkamp, Axel; Schulz-Drost, Stefan

    2017-01-01

    Introduction: Although shoulder girdle injuries are frequent, those of the medial clavicle are widely unexplored. An applied classification is less used just as a standard management. Methods: A retrospective analysis of medial clavicle injuries (MCI) during a 5-year-term in a Level-1-Trauma-Center. We analyzed amongst others concomitant injuries, therapy strategies and the classification following the AO standards. Results: 19 (2.5%) out of 759 clavicula injuries were medial ones (11 A, 6 B and 2 C-Type fractures) thereunder 27,8% were displaced and thus operatively treated Locked plate osteosynthesis was employed in unstable fractures and a reconstruction of the ligaments at the sternoclavicular joint (SCJ) in case of their disruption. 84,2% of the patients sustained relevant concomitant injuries. Numerous midshaft fractures were miscoded as medial fracture, which limited the study population. Conclusions: MCI resulted from high impact mechanisms of injury, often with relevant dislocation and concomitant injuries. Concerning medial injury's complexity, treatment should occur in specialized hospitals. Unstable fractures and injuries of the SCJ ligaments should be considered for operative treatment. Midshaft fractures should be clearly distinguished from the medial ones in ICD-10-coding. Further studies are required also regarding a subtyping of the AO classification for medial clavicle fractures including ligamental injuries. Celsius.

  12. Treatment of Thoracolumbar Fracture

    PubMed Central

    Kim, Byung-Guk; Shin, Dong-Eun

    2015-01-01

    The most common fractures of the spine are associated with the thoracolumbar junction. The goals of treatment of thoracolumbar fracture are leading to early mobilization and rehabilitation by restoring mechanical stability of fracture and inducing neurologic recovery, thereby enabling patients to return to the workplace. However, it is still debatable about the treatment methods. Neurologic injury should be identified by thorough physical examination for motor and sensory nerve system in order to determine the appropriate treatment. The mechanical stability of fracture also should be evaluated by plain radiographs and computed tomography. In some cases, magnetic resonance imaging is required to evaluate soft tissue injury involving neurologic structure or posterior ligament complex. Based on these physical examinations and imaging studies, fracture stability is evaluated and it is determined whether to use the conservative or operative treatment. The development of instruments have led to more interests on the operative treatment which saves mobile segments without fusion and on instrumentation through minimal invasive approach in recent years. It is still controversial for the use of these treatments because there have not been verified evidences yet. However, the morbidity of patients can be decreased and good clinical and radiologic outcomes can be achieved if the recent operative treatments are used carefully considering the fracture pattern and the injury severity. PMID:25705347

  13. Cracks dynamics under tensional stress - a DEM approach

    NASA Astrophysics Data System (ADS)

    Debski, Wojciech; Klejment, Piotr; Kosmala, Alicja; Foltyn, Natalia; Szpindler, Maciej

    2017-04-01

    Breaking and fragmentation of solid materials is an extremely complex process involving scales ranging from an atomic scale (breaking inter-atomic bounds) up to thousands of kilometers in case of catastrophic earthquakes (in energy scale it ranges from single eV up to 1024 J). Such a large scale span of breaking processes opens lot of questions like, for example, scaling of breaking processes, existence of factors controlling final size of broken area, existence of precursors, dynamics of fragmentation, to name a few. The classical approach to study breaking process at seismological scales, i.e., physical processes in earthquake foci, is essentially based on two factors: seismic data (mostly) and the continuum mechanics (including the linear fracture mechanics). Such approach has been gratefully successful in developing kinematic (first) and dynamic (recently) models of seismic rupture and explaining many of earthquake features observed all around the globe. However, such approach will sooner or latter face a limitation due to a limited information content of seismic data and inherit limitations of the fracture mechanics principles. A way of avoiding this expected limitation is turning an attention towards a well established in physics method of computational simulations - a powerful branch of contemporary physics. In this presentation we discuss preliminary results of analysis of fracturing dynamics under external tensional forces using the Discrete Element Method approach. We demonstrate that even under a very simplified tensional conditions, the fragmentation dynamics is a very complex process, including multi-fracturing, spontaneous fracture generation and healing, etc. We also emphasis a role of material heterogeneity on the fragmentation process.

  14. Surgical treatment of Ideberg type III glenoid fractures with associated superior shoulder suspensory complex injury.

    PubMed

    Qin, Hui; Hu, Chuan-Zhen; Zhang, Xian-Long; Shen, Long-Xiang; Xue, Zi-Chao; An, Zhi-Quan

    2013-10-01

    Ideberg type III glenoid fractures with associated superior shoulder suspensory complex (SSSC) injuries are rare, and related treatments have not been reported in the literature. The purpose of this study was to evaluate the clinical outcomes of such injuries treated with open reduction and internal fixation (ORIF). Between July 2007 and April 2012, ten patients with Ideberg type III glenoid fractures were surgically treated using ORIF with 2 cannulated screws or a screw combined with a metacarpal plate through an anterior approach. Patients with associated SSSC injuries underwent ORIF with K-wires or plates. Information was available for 9 patients with a mean follow-up of 24.1±18.2 months. Mean bone-healing time was 8.4±2.2 weeks. At last follow-up, mean forward flexion of the operative shoulder was 157.8°±7.5°, mean external rotation was 62.9°±7.9°, and mean internal rotation was thoracic level T6±0.8. Mean Constant score was 84.1±3.7 points, which was a mean of 92.7%±3.4% of that seen in the contralateral shoulder. Mean UCLA score and Disabilities of the Arm, Shoulder and Hand score were 33.6±1.7 and 16.6±7.7, respectively. The results show that Ideberg type III glenoid fractures with associated SSSC injuries can be successfully treated using ORIF through an anterior approach. Glenoid fractures and SCCC injuries should be treated simultaneously. Copyright 2013, SLACK Incorporated.

  15. Treatment of proximal ulna and olecranon fractures by dorsal plating.

    PubMed

    Kloen, Peter; Buijze, Geert A

    2009-12-01

    Anatomic reconstruction of proximal ulna and olecranon fractures allowing early mobilization and prevention of ulnohumeral arthritis. Comminuted olecranon or proximal ulna fractures (including Monteggia fractures), olecranon fractures extending distally from the coronoid process, nonunions of the proximal ulna, segmental fractures of the proximal ulna extending into the shaft, fractures of the proximal ulna associated with a coronoid fracture. Patients in poor general condition. Soft-tissue defects around the elbow preventing wound closure over the plate. Pediatric fractures with open growth plates where screws would cross the physis. Posterior approach to the elbow. Hinging the fracture site open by extension of the proximal fragment based on triceps insertion. Fracture involvement of the coronoid with a large displaced fracture fragment can generally be reduced through the fracture side. Reconstruction with temporary Kirschner wires. Fixation by placing a (precontoured) plate around the tip of the olecranon with a long intramedullary screw and orthogonal (uni)cortical screws in the shaft. Radial head pathology can be addressed - if needed - through the same incision. Internal fixation, resection or prosthetic replacement of the radial head is done based on injury pattern/stability. Functional rehabilitation using active assisted range of motion of the elbow may be started immediately out of splint. Posterior splint for 7-10 days to allow wound healing. Between 2003 and July 2008, 26 patients were treated with posterior plating of the proximal ulna and olecranon using this strategy. There were 23 acute fractures (of which one was referred for revision after suboptimal fixation a few days earlier), one nonunion that became traumatized, and two nascent malunions. A midline posterior approach allowed addressing both ulna and radial head pathology. The plate was contoured to wrap around the olecranon. All fractures healed. There were one postoperative infection, one transient ulnar neuropathy, one transient radial neuropathy, and one nonresolving ulnar/median neuropathy in a complex upper extremity injury. At follow-up after an average of 18 months, range of motion was on average 132 degrees /18 degrees of flexion/extension, and 75 degrees /70 degrees of pronation/supination. All fractures had healed at an average of 4.8 months. Ten patients had their hardware removed.

  16. Complex path flows in geological media imaged by X-Ray computed tomography

    NASA Astrophysics Data System (ADS)

    Neuville, Amélie; Ebner, Marcus; Toussaint, Renaud; Renard, François; Koehn, Daniel; Flekkøy, Eirik; Cochard, Alain

    2013-04-01

    Stylolites as well as fractures are reported as major conduits in geological media (1, 2). The flow circulation has a strong influence on hydro-mecanico-chemical processes, in particular on crystallization and dissolution (3, 4). For instance hydrothermal ore deposits are frequently located in stylolites and fractures at depth. The fluid pressure also intervenes as a thermodynamic parameter in chemical reactions, and is in addition responsible for elastic deformations of the medium. Using tridimensional numerical simulations, we aim at better characterizing the flow circulation in complex structures, and at investigating on how the flow modifies the geological medium. First, X-Ray computed tomography scans of a complete stylolite structure (i.e. calcareous matrix, clay layering in the aperture, and the very thin aperture itself), and that of a fractured sandstone sample were performed. Then, image processing is required in order to extract the geometry of the porous medium of each sample. The geometries are actually more complicated than that of classical fractures, because of the existence of non connected -- or barely connected -- void spaces. We report on the influence of this image processing on the aperture geometry and on the computed permeability. This is addressed by first performing a numerical simulation of the tridimensional velocity field, using a coupled lattice Boltzmann method that solves the complete Navier-Stokes equation. After calculating the velocity field we then question the link between the geometry of complex stylolites and fractures, and the spatial auto-correlation of the velocity field. This correlation might indeed be important for dispersion processes. A first approach is to compute this correlation from the simulated velocity field. Another approach is to compute analytically the correlation function, from the knowledge of the aperture correlation. This is however developed in the perturbative limit of small aperture variations, that may not hold for the apertures found in stylolites. We then present the pressure field obtained within these complex structures, and give preliminary tracks on how variations of the pressure might be responsible for transformations of the medium, that affect its mechanical and transport properties. 1 A Neuville, R Toussaint, and J Schmittbuhl (2010) Hydro-thermal flows in a self-affine rough fracture. Physical Review E, 82, 036317 2 André G., C. Hibsch, S. Fourcade, M. Cathelineau and S. Buschaert (2010) Chronology of fracture sealing under a meteoric fluid environment: Microtectonic and isotopic evidence of major Cainozoic events in the eastern Paris Basin (France). Tectonophysics, 490, 214-228 3 Laronne Ben-Itzhak, L., E. Aharonov, R. Toussaint and A. Sagy (2012) Upper bound on stylolite roughness as indicator for the duration and amount of dissolution. Earth and Planetary Science Letters, 337-338, 186-196 4 Angheluta, L., J. Mathiesen, E. Aharonov (2012) Compaction of porous rock by dissolution on discrete stylolites: A one-dimensional model. Journal of Geophysical Research -- Solid Earth, 117, B08203

  17. Summary and interpretation of dye-tracer tests to investigate the hydraulic connection of fractures at a ridge-and-valley-wall site near Fishtrap Lake, Pike County, Kentucky

    USGS Publications Warehouse

    Taylor, Charles J.

    1994-01-01

    Dye-tracer tests were done during 1985-92 to investigate the hydraulic connection between fractures in Pennsylvanian coal-bearing strata at a ridge-and-valley-wall site near Fishtrap Lake, Pike County, Ky. Fluorescent dye was injected into a core hole penetrating near-surface and mining-induced fractures near the crest of the ridge. The rate and direction of migration of dye in the subsurface were determined by measuring the relative concentration of dye in water samples collected from piezometers completed in conductive fracture zones and fractured coal beds at various stratigraphic horizons within the ridge. Dye-concentration data and water-level measurements for each piezometer were plotted as curves on dye-recovery hydrographs. The dye-recovery hydrographs were used to evaluate trends in the fluctuation of dye concentrations and hydraulic heads in order to identify geologic and hydrologic factors affecting the subsurface transport of dye. The principal factors affecting the transport of dye in the subsurface hydrologic system were determined to be (1) the distribution, interconnection, and hydraulic properties of fractures; (2) hydraulic-head conditions in the near-fracture zone at the time of dye injection; and (3) subsequent short- and long-term fluctuations in recharge to the hydrologic system. In most of the dye-tracer tests, dye-recovery hydrographs are characterized by complex, multipeaked dye-concentration curves that are indicative of a splitting of dye flow as ground water moved through fractures. Intermittent dye pulses (distinct upward spikes in dye concentration) mark the arrivals of dye-labeled water to piezometers by way of discrete fracture-controlled flow paths that vary in length, complexity, and hydraulic conductivity. Dye injections made during relatively high- or increasinghead conditions resulted in rapid transport of dye (within several days or weeks) from near-surf ace fractures to piezometers. Injections made during relatively low- or decreasing-head conditions resulted in dye being trapped in hydraulically dead zones in water-depleted fractures. Residual dye was remobilized from storage and transported (over periods ranging from several months to about 2 years) by increased recharge to the hydrologic system. Subsequent fluctuations in hydraulic gradients, resulting from increases or decreases in recharge to the hydrologic system, acted to speed or slow the transport of dye along the fracture-controlled flow paths. The dye-tracer tests also demonstrated that mining-related disturbances significantly altered the natural fracture-controlled flow paths of the hydrologic system over time. An abandoned underground mine and subsidence-related surface cracks extend to within 250 ft of the principal dye-injection core hole. Results from two of the dye-tracer tests at the site indicate that the annular seal in the core hole was breached by subsurface propagation of the mining-induced fractures. This propagation of fractures resulted in hydraulic short-circuiting between the dye-injection zone in the core hole and two lower piezometer zones, and a partial disruption of the hydraulic connection between the injection core hole and downgradient piezometers on the ridge crest and valley wall. In addition, injected dye was detected in piezometers monitoring a flooded part of the abandoned underground mine. Dye was apparently transported into the mine through a hydraulic connection between the injection core hole and subsidence-related fractures.

  18. Complex ruptures during hydraulic fracturing of the Marcellus Shale

    NASA Astrophysics Data System (ADS)

    Viegas, G. F.; Urbancic, T.; Bosman, K.; Baig, A. M.

    2016-12-01

    Complex rupture patterns were observed on several M0+ events recorded during a hydraulic stimulation of the Marcellus shale. Although M>0 events associated with hydraulic fracturing have now been commonly recorded and may cause concern in terms of public and infrastructure safety, the vast majority of these events are smaller than M3 and are not felt at the surface. We investigate the rupture characteristics of one such multi-rupture event with 3 sub-events, by examining the failure dynamics of the overall fracture itself and of each individual sub-event, and the growth of the overall fracture from rupture initiation to arrest. This analysis is only possible due to the wide frequency range of the seismic monitoring system put in place which spanned from 0.1 Hz to 1000 Hz. The monitoring system consists of: high-frequency sensor-arrays of geophones deployed downhole close to the reservoir and thus to the rupture initiation point; and low to intermediate frequency accelerometers and geophones deployed at intermediate and shallow depths, allowing for the investigation of overall rupture characteristics. We aim to gain an understanding of the role of asperities, fracture roughness, and fluids on the different aspects of the rupture processes and of the failure mechanisms (shearing versus tensile dominance of behavior) associated with these complex events. Our results show that the overall event is characterized by the failure of multiple asperities and the distance between the 3 sub-events is less than 20 m. We observe decreasing stress drop and increasing Mw over time for the successive sub-events which suggest decreasing frictional resistance due to the presence of fluids over an increasingly large rupture surface akin to increased slip over a larger and less resistant contact area such as an asperity. The overall failure shows a dominant shearing mode mechanism whereas the sub-events failures show strong tensile components. The ruptures of the 1st and 2nd sub-events are indicative of shear-compaction of an asperity and the one of the 3rd sub-event is suggestive of a rupture riding over several surface patches. Additional analysis of other complex events will improve the characterization of the rupture processes of these larger-magnitude events and allow for the assessment of conditions under which the failures occur.

  19. Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 4: Failure analysis of 10 fractured retaining screws retrieved from three patients.

    PubMed

    Al Jabbari, Youssef S; Fournelle, Raymond; Ziebert, Gerald; Toth, Jeffrey; Iacopino, Anthony M

    2008-04-01

    The aim of this study was to perform a failure analysis on fractured prosthetic retaining screws after long-term use in vivo. Additionally, the study addresses the commonly asked question regarding whether complex repeated functional occlusal forces initiate fatigue-type cracks in prosthetic retaining screws. Ten fractured prosthetic retaining screws retrieved from three patients treated with fixed detachable hybrid prostheses were subjected to a failure analysis. In patients 1 and 2, the middle three retaining screws of the prostheses were found fractured at retrieval time after they had been in service for 20 and 19 months, respectively. In patient 3, the middle three and one of the posterior retaining screws were found to be fractured at retrieval after they had been in service for 18 months. Low power stereomicroscopy and high-power scanning electron microscopy (SEM) were performed to analyze the fractured surfaces of the retaining screws examining fatigue cracks in greater detail. Typical fatigue failure characterized by ratchet mark formation was revealed by light microscopy and SEM for all examined screws. Using low magnification light microscopy, ratchet marks were visible on the fracture surfaces of only two screws. SEM examination revealed all three classical stages of fatigue failure, and it was possible to see the ratchet marks on the fracture surfaces of all specimens, indicating a fatigue zone. The final catastrophic overload fracture appeared fibrous, indicating ductile fracture. The final overload ductile fracture surfaces showed equiaxed dimples, suggesting tensile overload in all examined screws except in two specimens that showed an elongated dimple pattern indicating shear/tearing overload forces. Fracture of prosthetic retaining screws in hybrid prostheses occurs mainly through a typical fatigue mode involving mostly the middle anterior three screws. Fatigue cracks can grow in more than one prosthetic retaining screw, leading to fracture before the patient or clinician determines that any problem exists.

  20. P-wave velocity anisotropy related to sealed fractures reactivation tracing the structural diagenesis in carbonates

    NASA Astrophysics Data System (ADS)

    Matonti, C.; Guglielmi, Y.; Viseur, S.; Garambois, S.; Marié, L.

    2017-05-01

    Fracture properties are important in carbonate reservoir characterization, as they are responsible for a large part of the fluid transfer properties at all scales. It is especially true in tight rocks where the matrix transfer properties only slightly contribute to the fluid flow. Open fractures are known to strongly affect seismic velocities, amplitudes and anisotropy. Here, we explore the impact of fracture evolution on the geophysical signature and directional Vp anisotropy of fractured carbonates through diagenesis. For that purpose, we studied a meter-scale, parallelepiped quarry block of limestone using a detailed structural and diagenetic characterization, and numerous Vp measurements. The block is affected by two en-échelon fracture clusters, both being formed in opening mode (mode 1) and cemented, but only one being reactivated in shear. We compared the diagenetic evolution of the fractures, which are almost all 100% filled with successive calcite cements, with the P-wave velocities measured across this meter-scale block of carbonate, which recorded the tectonic and diagenetic changes of a South Provence sedimentary basin. We found that a directional Vp anisotropy magnitude as high as 8-16% correlates with the reactivated fractures' cluster dip angle, which is explained by the complex filling sequence and softer material present inside the fractures that have been reactivated during the basin's tectonic inversion. We show that although a late karstification phase preferentially affected these reactivated fractures, it only amplified the pre-existing anisotropy due to tectonic shear. We conclude that Vp anisotropy measurements may help to identify the fracture sealing/opening processes associated with polyphased tectonic history, the anisotropy being independent of the current stress-state. This case shows that velocity anisotropies induced by fractures resulted here from a cause that is different from how these features have often been interpreted: selective reactivation of sealed fractures clusters rather than direction of currently open ones.

  1. Coupled Fracture and Flow in Shale in Hydraulic Fracturing

    NASA Astrophysics Data System (ADS)

    Carey, J. W.; Mori, H.; Viswanathan, H.

    2014-12-01

    Production of hydrocarbon from shale requires creation and maintenance of fracture permeability in an otherwise impermeable shale matrix. In this study, we use a combination of triaxial coreflood experiments and x-ray tomography characterization to investigate the fracture-permeability behavior of Utica shale at in situ reservoir conditions (25-50 oC and 35-120 bars). Initially impermeable shale core was placed between flat anvils (compression) or between split anvils (pure shear) and loaded until failure in the triaxial device. Permeability was monitored continuously during this process. Significant deformation (>1%) was required to generate a transmissive fracture system. Permeability generally peaked at the point of a distinct failure event and then dropped by a factor of 2-6 when the system returned to hydrostatic failure. Permeability was very small in compression experiments (< 1 mD), possibly because of limited fracture connectivity through the anvils. In pure share experiments, shale with bedding planes perpendicular to shear loading developed complex fracture networks with narrow apertures and peak permeability of 30 mD. Shale with bedding planes parallel to shear loading developed simple fractures with large apertures and a peak permeability as high as 1 D. Fracture systems held at static conditions for periods of several hours showed little change in effective permeability at hydrostatic conditions as high as 140 bars. However, permeability of fractured systems was a function of hydrostatic pressure, declining in a pseudo-linear, exponential fashion as pressure increased. We also observed that permeability decreased with increasing fluid flow rate indicating that flow did not follow Darcy's Law, possibly due to non-laminar flow conditions, and conformed to Forscheimer's law. The coupled deformation and flow behavior of Utica shale, particularly the large deformation required to initiate flow, indicates the probable importance of activation of existing fractures in hydraulic fracturing and that these fractures can have adequate permeability for the production of hydrocarbon.

  2. Hydro-mechanical coupled simulation of hydraulic fracturing using the eXtended Finite Element Method (XFEM)

    NASA Astrophysics Data System (ADS)

    Youn, Dong Joon

    This thesis presents the development and validation of an advanced hydro-mechanical coupled finite element program analyzing hydraulic fracture propagation within unconventional hydrocarbon formations under various conditions. The realistic modeling of hydraulic fracturing is necessarily required to improve the understanding and efficiency of the stimulation technique. Such modeling remains highly challenging, however, due to factors including the complexity of fracture propagation mechanisms, the coupled behavior of fracture displacement and fluid pressure, the interactions between pre-existing natural and initiated hydraulic fractures and the formation heterogeneity of the target reservoir. In this research, an eXtended Finite Element Method (XFEM) scheme is developed allowing for representation of single or multiple fracture propagations without any need for re-meshing. Also, the coupled flows through the fracture are considered in the program to account for their influence on stresses and deformations along the hydraulic fracture. In this research, a sequential coupling scheme is applied to estimate fracture aperture and fluid pressure with the XFEM. Later, the coupled XFEM program is used to estimate wellbore bottomhole pressure during fracture propagation, and the pressure variations are analyzed to determine the geometry and performance of the hydraulic fracturing as pressure leak-off test. Finally, material heterogeneity is included into the XFEM program to check the effect of random formation property distributions to the hydraulic fracture geometry. Random field theory is used to create the random realization of the material heterogeneity with the consideration of mean, standard deviation, and property correlation length. These analyses lead to probabilistic information on the response of unconventional reservoirs and offer a more scientific approach regarding risk management for the unconventional reservoir stimulation. The new stochastic approach combining XFEM and random field is named as eXtended Random Finite Element Method (XRFEM). All the numerical analysis codes in this thesis are written in Fortran 2003, and these codes are applicable as a series of sub-modules within a suite of finite element codes developed by Smith and Griffiths (2004).

  3. Management of Fractured Inferior Vena Cava Filters: Outcomes by Fragment Location.

    PubMed

    Trerotola, Scott O; Stavropoulos, S William

    2017-09-01

    Purpose To inform the management of fractured inferior vena cava filters on the basis of results from a tertiary referral center specializing in complex filter retrieval. Materials and Methods This study had institutional review board approval and was HIPAA compliant. Retrospective analysis of all patients with fractured filters and/or filter fragments evaluated for removal in a complex filter removal program was performed. Removal was attempted when fragments were intravascular or immediately extravascular by using primarily endobronchial forceps for caval fragments and snares for cardiac and pulmonary fragments. Data collected included success rate and complications of filter and fragment removal, symptoms relating to the filter or fragment, techniques used for removal, and follow-up of retained fragments. Results Sixty-five patients (12 men, 53 women) of a total of 222 patients referred for complex retrieval had fractured filters. Of these patients, two had undergone filter removal elsewhere and had retained fragments. All 63 filters were removed successfully with forceps (n = 61), a cone (n = 1), or a snare (n = 1). There were 116 separate filter fragments; removal was attempted for 78 fragments. Removal was successful for 63 (81%) of 78 fragments and varied by location. All extravascular fragments except one were retained. In all, 63 (54%) of 116 fragments were removed percutaneously, rendering 34 (54%) of 63 patients fragment free. Five minor (7.7% [five of 65]) and four major (6.2% [four of 65]) complications occurred. Conclusion Intravascular filter fragments can be removed safely with success rates that vary according to location. Because extravascular fragments are not readily accessible for removal, many patients are not rendered fragment free. © RSNA, 2017 Online supplemental material is available for this article.

  4. Hydromechanical and Thermomechanical Behaviour of Elastic Fractures during Thermal Stimulation of Naturally Fractured Reservoirs

    NASA Astrophysics Data System (ADS)

    Jalali, Mohammadreza; Valley, Benoît

    2015-04-01

    During the last two decades, incentives were put in place in order to feed our societies in energy with reduced CO2 emissions. Various policies have been considered to fulfill this strategy such as replacing coal by natural gas in power plants, producing electricity using CO2 free resources, and CO2 sequestration as a remediation for large point-source emitters (e.g. oil sands facilities, coal-fired power plants, and cement kilns). Naturally fractured reservoirs (NFRs) are among those geological structures which play a crucial role in the mentioned energy revolution. The behavior of fractured reservoirs during production processes is completely different than conventional reservoirs because of the dominant effects of fractures on fluid flux, with attendant issues of fracture fabric complexity and lithological heterogeneity. The level of complexity increases when thermal effects are taking place - as during the thermal stimulation of these stress-sensitive reservoirs in order to enhance the gas production in tight shales and/or increase the local conductivity of the fractures during the development of enhanced geothermal systems - where temperature is introduced as another degree of freedom in addition to pressure and displacement (or effective stress). Study of these stress-pressure-temperature effects requires a thermo-hydro-mechanical (THM) coupling approach, which considers the simultaneous variation of effective stress, pore pressure, and temperature and their interactions. In this study, thermal, hydraulic and mechanical behavior of partially open and elastic fractures in a homogeneous, isotropic and low permeable porous rock is studied. In order to compare the hydromechanical (HM) and thermomechanical (TM) characteristics of these fractures, three different injection scenarios, i.e. constant isothermal fluid injection rate, constant cooling without any fluid injection and constant cold fluid injection, are considered. Both thermomechanical and hydromechanical behaviors become dominant at different time scales, i.e. HM effects is dominant at early time after injection initiation, whereas the TM effect becomes more dominant at later time as the temperature propagation is slower than pressure propagation in the rock due to different value of hydraulic and thermal diffusivities. Due to the relative similarity of thermoelasticity and poroelasticity on the mechanical behavior of fractures, an analogy between these two mechanisms is introduced which can be used to estimate the effect of one of the mechanisms based on the other one on the mechanical behavior of the considered medium in the cases where only one of the solution exists. There may be merit in developing this work to generate more accurate and higher order functions to represent fractures within a general analogy of THM coupled problems as the computational time of this approach is at least one order less than the conventional THM iterative approaches.

  5. Bisphosphonates inhibit pain, bone loss, and inflammation in a rat tibia fracture model of complex regional pain syndrome

    PubMed Central

    Wang, Liping; Guo, Tian-Zhi; Wei, Tzuping; Li, Wen-wu; Shi, Xiaoyou; Clark, J David; Kingery, Wade S

    2016-01-01

    BACKGROUND Bisphosphonates are used to prevent the bone loss and fractures associated with osteoporosis, bone metastases, multiple myeloma, and osteogenis deformans. Distal limb fractures cause regional bone loss with cutaneous inflammation and pain in the injured limb that can develop into complex regional pain syndrome (CRPS). Clinical trials have reported that anti-resorptive bisphosphonates can prevent fracture-induced bone loss, inhibit serum inflammatory cytokine levels, and alleviate CRPS pain. Previously we observed that the inhibition of inflammatory cytokines or adaptive immune responses attenuated the development of pain behavior in a rat fracture model of CRPS and we hypothesized that bisphosphonates could prevent pain behavior, trabecular bone loss, post-fracture cutaneous cytokine up-regulation, and adaptive immune responses in this CRPS model. METHODS Rats underwent tibia fracture and cast immobilization for 4 weeks and were chronically administered either subcutaneously perfused alendronate or oral zoledronate. Behavioral measurements included hindpaw von Frey allodynia, unweighting, warmth, and edema. Bone microarchitecture was measured by uCT and bone cellular activity was evaluated by static and dynamic histomorphometry. Spinal cord Fos immunostaining was performed and skin cytokine (TNF, IL-1, IL-6) and nerve growth factor (NGF) levels were determined by EIA. Skin and sciatic nerve immunoglobulin levels were determined by EIA. RESULTS Tibia fracture rats developed hindpaw allodynia, unweighting, warmth, and edema, increased spinal Fos expression, trabecular bone loss in the lumbar vertebra and bilateral distal femurs as measured by uCT, increased trabecular bone resorption and osteoclast surface with decreased bone formation rates, increased cutaneous inflammatory cytokine and NGF expression and elevated immunocomplex deposition in skin and nerve. Alendronate (60 μg/kg/day s.c.) or zoledronate (3 mg/kg/day p.o.) treatment for 28 days, started at the time of fracture, completely inhibited the development of hindpaw allodynia and reduced hindpaw unweighting by 44 ± 13% and 58 ± 5%, respectively. Orally administered zoledronate (3 mg/kg/day for 21 days) treatment also completely reversed established allodynia and unweighting when started at 4-weeks post-fracture. Histomorphometric and uCT analysis demonstrated that both the 3 and 60 μg/kg/day alendronate treatments reversed trabecular bone loss (a 88 ± 25% and 188 ± 39% increase in the ipsilateral distal femur BV/TV, respectively) and blocked the increase in osteoclast numbers and erosion surface observed in bilateral distal femurs and in L5 vertebra of the fracture rats. Alendronate treatment inhibited fracture-induced increases in hindpaw inflammatory mediators, reducing post-fracture levels of TNF by 43 ± 9%, IL-1 by 60 ± 9%, IL-6 by 56 ± 14%, and NGF by 37 ± 14%, but had no effect on increased spinal cord Fos expression, or skin and sciatic nerve immunocomplex deposition. CONCLUSIONS Collectively, these results indicate that bisphosphonate therapy inhibits pain, osteoclast activation, trabecular bone loss, and cutaneous inflammation in the rat fracture model of CRPS, data supporting the hypothesis that bisphosphonate therapy can provide effective multimodal treatment for CRPS. PMID:27636578

  6. Ability of modern distal tibia plates to stabilize comminuted pilon fracture fragments: Is dual plate fixation necessary?

    PubMed

    Penny, Phillip; Swords, Michael; Heisler, Jason; Cien, Adam; Sands, Andrew; Cole, Peter

    2016-08-01

    The purpose of this study was to examine the screw trajectory of ten commercially available distal tibia plates and compare them to common fracture patterns seen in OTA C type pilon fractures to determine their ability to stabilize the three most common fracture fragments while buttressing anterolateral zones of comminution. We hypothesized that a single plate for the distal tibia would fail to adequately stabilize all three main fracture fragments and zones of comminution in complex pilon fractures. Ten synthetic distal tibia sawbones models were used in conjunction with ten different locking distal tibia plate designs from three manufacturers (Depuy Synthes, J&J Co, Paoli, PA; Smith & Nephew, Memphis, TN; and Stryker, Mawa, NJ). Both medial and anterolateral plates from each company were utilized and separately applied to an individual sawbone model. Three implants allowing variable angle screw placement were used. The location of the locking screws and buttress effect 1cm above the articular surface was noted for each implant using axial computed tomography (CT). The images were then compared to a recently published "pilon fracture map" using an overlay technique to establish the relationship between screw location and known common fracture lines and areas of comminution. Each of the three main fragments was considered "captured" by a screw if it was purchased by at least two screws thereby controlling rotational forces on each fragment. Three of four anterolateral plates lacked stable fixation in the medial fragment. Of the 4 anterolateral plates used, only the variable angle anterolateral plate by Depuy Synthes captured the medial fragment with two screws. All four anterolateral plates buttressed the area of highest comminution and had an average of 1.25 screws in the medial fragment and an average of 3 screws in the posterolateral fragment. All five direct medial plates had variable fixation within anterolateral and posterolateral fragments with an average of 1.8 screws in the anterolateral fragment and an average of 1.3 screws in the posterolateral fragment. The Depuy Synthes variable angle anterolateral plate allowed for fixation of the medial fragment with two screws while simultaneously buttressing the zone of highest comminution and capturing both the anterolateral and posterolateral fragments with five and three screws respectively. The variable angle anteromedial plate by Depuy Synthes captured all three main fracture fragments but it did not buttress the anterolateral zone of comminution. In OTA 43C type pilon fractures, 8 out of 10 studied commercially available implants precontoured for the distal tibia, do not adequately stabilize the three primary fracture fragments typically seen in these injuries. Anterolateral plates were superior in addressing the coronal primary fracture line across the apex of the plafond, and buttressing the zone of comminution. None of the available plates can substitute for an understanding of the fracture planes and fragments typically seen in complex intra-articular tibia fractures and the addition of a second plate is necessary for adequate stability. Level IV. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Application of imaging spectrometer data to the Kings-Kaweah ophiolite melange

    NASA Technical Reports Server (NTRS)

    Mustard, John F.; Pieters, Carle M.

    1988-01-01

    The Kings-Kaweah ophiolite melange in east-central California is thought to be an obducted oceanic fracture zone and provides the rare opportunity to examine in detail the complex nature of this type of terrain. It is anticipated that the distribution and abundance of components in the melange can be used to determine the relative importance of geologic processes responsible for the formation of fracture zone crust. Laboratory reflectance spectra of field samples indicate that the melange components have distinct, diagnostic absorptions at visible to near-infrared wavelengths. The spatial and spectral resolution of AVIRIS is ideally suited for addressing important scientific questions concerning the Kings-Kaweah ophiolite melange and fracture zones in general.

  8. Use of the S3 Corridor for Iliosacral Fixation in a Dysmorphic Sacrum: A Case Report.

    PubMed

    El Dafrawy, Mostafa H; Strike, Sophia A; Osgood, Greg M

    2017-01-01

    The S1 and S2 corridors are the typical osseous pathways for iliosacral screw fixation of posterior pelvic ring fractures. In dysmorphic sacra, the S1 screw trajectory is often different from that in normal sacra. We present a case of iliosacral screw placement in the third sacral segment for fixation of a complex lateral compression type-3 pelvic fracture in a patient with a dysmorphic sacrum. In patients with dysmorphic sacra and unstable posterior pelvic ring fractures or dislocations, the S3 corridor may be a feasible osseous fixation pathway that can be used in a manner equivalent to the S2 corridor in a normal sacrum.

  9. Experimental and Numerical Analysis of Fracture in 41Cr4 Steel - Issues of the Stationary Cracks

    NASA Astrophysics Data System (ADS)

    Graba, M.

    2018-02-01

    This paper analyzes the process of fracture in 41Cr4 steel on the basis of experimental and numerical data obtained for non-propagating cracks. The author's previous and latest experimental results were used to determine the apparent crack initiation moment and fracture toughness for the material under plane strain conditions. Numerical simulations were carried out to assess changes in the J-integral, the crack tip opening displacement, the size of the plastic region and the distribution of stresses around the crack tip. A complex numerical analysis based on the true stress-strain curve was performed to determine the behavior of 41Cr4 steel under increasing external loads.

  10. Geological study of the southern part of the Malagasy republic using ERTS orbital images

    NASA Technical Reports Server (NTRS)

    Weecksteen, G. (Principal Investigator); Scanvic, J. Y.; Koch, B.

    1974-01-01

    The author has identified the following significant results. The Malagasy stratigraphy and tectonic are very complex, but the results obtained using ERTS-1 images interpretation make credible some hypothesis recently proposed by geologists. Most of known fractures are identified and numerous new observations are made on these images in the field of linear fractures. Some of them extend or relay known fractures and many others are totally new even if scattered field observations make it possible to assume that they correspond to reality. In the domain of lithology different types of rocks are distinguished, but the results are better in sedimentary formations than in the basement.

  11. Patterns of triangular fibrocartilage complex (TFCC) injury associated with severely dorsally displaced extra-articular distal radius fractures.

    PubMed

    Scheer, Johan H; Adolfsson, Lars E

    2012-06-01

    The aim of the study was to examine triangular fibrocartilage (TFCC) injury patterns associated with unstable, extra-articular dorsally displaced distal radius fractures. Twenty adult patients with an Arbeitsgemeinschaft für Osteosynthesefragen (AO), type A2 or A3, distal radius fracture with an initial dorsal angulation greater than 20° were included. Nine had a tip fracture (distal to the base) of the ulnar styloid and 11 had no such fracture. They were all openly explored from an ulnopalmar approach and TFCC injuries were documented. Eleven patients also underwent arthroscopy and intra-articular pathology was recorded. All patients had TFCC lesions of varying severity, having an extensor carpi ulnaris subsheath avulsion in common. Eighteen out of 20 also displayed deep foveal radioulnar ligament lesions, with decreasingly dorsal fibres remaining. The extent of this foveal injury could not be appreciated by radiocarpal arthroscopy. Severe displacement of an extra-articular radius fracture suggests an ulnar-sided ligament injury to the TFCC. The observed lesions concur with findings in a previous cadaver study. The lesions follow a distinct pattern affecting both radioulnar as well as ulnocarpal stabilisers. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Crystalline and Crystalline International Disposal Activities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Viswanathan, Hari S.; Chu, Shaoping; Dittrich, Timothy M.

    This report presents the results of work conducted between September 2015 and July 2016 at Los Alamos National Laboratory in the crystalline disposal and crystalline international disposal work packages of the Used Fuel Disposition Campaign (UFDC) for DOE-NE’s Fuel Cycle Research and Development program. Los Alamos focused on two main activities during this period: Discrete fracture network (DFN) modeling to describe flow and radionuclide transport in complex fracture networks that are typical of crystalline rock environments, and a comprehensive interpretation of three different colloid-facilitated radionuclide transport experiments conducted in a fractured granodiorite at the Grimsel Test Site in Switzerland betweenmore » 2002 and 2013. Chapter 1 presents the results of the DFN work and is divided into three main sections: (1) we show results of our recent study on the correlation between fracture size and fracture transmissivity (2) we present an analysis and visualization prototype using the concept of a flow topology graph for characterization of discrete fracture networks, and (3) we describe the Crystalline International work in support of the Swedish Task Force. Chapter 2 presents interpretation of the colloidfacilitated radionuclide transport experiments in the crystalline rock at the Grimsel Test Site.« less

  13. Investigation Study on Determination of Fracture Strain and Fractuer Forming Limit Curve Using Different Experimental and Numerical Methods

    NASA Astrophysics Data System (ADS)

    Farahnak, P.; Urbanek, M.; Džugan, J.

    2017-09-01

    Forming Limit Curve (FLC) is a well-known tool for the evaluation of failure in sheet metal process. However, its experimental determination and evaluation are rather complex. From theoretical point of view, FLC describes initiation of the instability not fracture. During the last years Digital Image Correlation (DIC) techniques have been developed extensively. Throughout this paper, all the measurements were done using DIC and as it is reported in the literature, different approaches to capture necking and fracture phenomena using Cross Section Method (CSM), Time dependent Method (TDM) and Thinning Method (TM) were investigated. Each aforementioned method has some advantages and disadvantages. Moreover, a cruciform specimen was used in order to cover whole FLC in the range between uniaxial to equi-biaxial tension and as an alternative for Nakajima test. Based on above-mentioned uncertainty about the fracture strain, some advanced numerical failure models can describe necking and fracture phenomena accurately with consideration of anisotropic effects. It is noticeable that in this paper, dog-bone, notch and circular disk specimens are used to calibrate Johnson-Cook (J-C) fracture model. The results are discussed for mild steel DC01.

  14. A review on recent contribution of meshfree methods to structure and fracture mechanics applications.

    PubMed

    Daxini, S D; Prajapati, J M

    2014-01-01

    Meshfree methods are viewed as next generation computational techniques. With evident limitations of conventional grid based methods, like FEM, in dealing with problems of fracture mechanics, large deformation, and simulation of manufacturing processes, meshfree methods have gained much attention by researchers. A number of meshfree methods have been proposed till now for analyzing complex problems in various fields of engineering. Present work attempts to review recent developments and some earlier applications of well-known meshfree methods like EFG and MLPG to various types of structure mechanics and fracture mechanics applications like bending, buckling, free vibration analysis, sensitivity analysis and topology optimization, single and mixed mode crack problems, fatigue crack growth, and dynamic crack analysis and some typical applications like vibration of cracked structures, thermoelastic crack problems, and failure transition in impact problems. Due to complex nature of meshfree shape functions and evaluation of integrals in domain, meshless methods are computationally expensive as compared to conventional mesh based methods. Some improved versions of original meshfree methods and other techniques suggested by researchers to improve computational efficiency of meshfree methods are also reviewed here.

  15. Prevalence and risk factors for nonvertebral bone fractures in kidney transplant recipients - a single-center retrospective analysis.

    PubMed

    Jerman, Alexander; Lindič, Jelka; Škoberne, Andrej; Borštnar, Špela; Martinuč Bergoč, Maja; Godnov, Uroš; Kovač, Damjan

    Complex and longstanding bone disease superimposed by harmful influences of immunosuppression is the reason for increased risk of bone fracture in kidney transplant recipients. The aim of our study was to analyze the incidence and prevalence of nonvertebral bone fractures and early (in the first post-transplant year) clinical and laboratory risk factors for suffering bone fracture in the long-term post-transplant period. Clinical and laboratory data as well as bone mineral density (BMD) measurements of 507 first kidney transplant recipients who were transplanted in the period from 1976 to 2011 were analyzed. The mean age of included patients was 54.3 ± 12.0 years, there were 45% females, and mean time on renal replacement treatment prior to transplantation was 63.4 ± 43.6 months. The average observation time post-transplant was 9.7 years (1.4 - 36.3 years). Post-transplant, 64 (12.6%) patients suffered 89 nonvertebral fractures (44 patients suffered 1 fracture, 15 patients 2 fractures, and 5 patients 3 fractures). Patients with fractures had significantly lower late BMD of femoral neck in the period of 1 - 10 years post-transplant, had osteopenia and osteoporosis more frequently in the same time period, and higher serum alkaline phosphatase in the first year post-transplant. 13 patients (13/64, 20.3%) had major fractures. Patients with major fractures were significantly older than patients with no major fractures and had lower serum albumin. Frequency of treatment with bisphosphonate, calcium, or phosphate did not differ between the groups. Vitamin D supplement (active form in 98% of cases) was prescribed more frequently in the group without fractures, but this was not statistically significant. Fracture rate in our transplant patient population was comparable to that reported in the literature. Except for a higher level of serum total alkaline phosphatase in the fracture group, we found no other early laboratory risk factors for bone fractures. BMD at the femoral region 1 - 10 years after kidney transplantation but not BMD at the time of transplantation was a risk factor for nonvertebral fractures. Osteopenia and osteoporosis in the post-transplant period were found to be a fracture risk factor.
.

  16. Mechanical development of folded chert beds in Monterey Formation, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crowther, D.; Snyder, W.S.

    1988-03-01

    Small-scale folds in the upper siliceous facies of the Miocene Monterey Formation, at Lions Head, California (Santa Maria basin) are of tectonic origin. Folding is well developed in the chert-dominated zones and dies out rapidly in the adjacent siliceous mudstones. A tectonic origin is evidenced by the dominantly brittle deformation of the competent chert layers. Mechanically, the folds formed through a complex interrelationship between fracture and flexural slip. Opal-CT and quartz-chert layers display brittle fractures and rotated fracture blocks that responded to shortening. Thrusting of the chert layers is common in folds where fold propagation was impeded. Dilation breccia andmore » void space occur in the hinges and reflect room problems during development of these disharmonic folds. Subsequent diagenesis has partially healed the fractures and slip surfaces, creating the erroneous appearance that ductile deformation was an important factor in the formation of the folds.« less

  17. Fracture analysis of radial scientific instrument module registration fittings of the space telescope

    NASA Technical Reports Server (NTRS)

    Springfield, C. W., Jr.

    1985-01-01

    The space telescope contains various scientific instrument (SI) modules which are mounted to the Focal Plane Structure (FPS) in a statically determinate manner. This is accomplished by using three registration fittings per SI module, one resisting three translations, another resisting two and the third resisting only one. Due to thermal insulating requirements these fittings are complex devices composed of numerous pieces. The structural integrity of these fittings is of great importance to the safety of the orbiter transporting the telescope, so in addition to the stress analyses performed during the design of these components, fracture susceptibility also needs to be considered. The pieces of the registration fittings for the Radial SI Module containing the Wide Field Planetary Camera are examined to determine which would endanger the orbiter if they fractured and what is the likelihood of their fracture. The latter is stated in terms of maximum allowable initial flaw sizes in these pieces.

  18. Current Status of Research on Osteoporosis after Solid Organ Transplantation: Pathogenesis and Management

    PubMed Central

    2015-01-01

    Improved survival following organ transplantation has brought to the forefront some long-term complications, among which osteoporosis and associated fractures are the major ones that adversely affect the quality of life in recipients. The pathogenesis of osteoporosis in transplant recipients is complex and multifactorial which may be related to increased bone resorption, decreased bone formation, or both. Studies have shown that the preexisting underlying metabolic bone disorders and the use of immunosuppressive agents are the major risk factors for osteoporosis and fractures after organ transplantation. And rapid bone loss usually occurs in the first 6–12 months with a significant increase in fracture risk. This paper will provide an updated review on the possible pathogenesis of posttransplant osteoporosis and fractures, the natural history, and the current prevention and treatment strategies concerning different types of organ transplantation. PMID:26649301

  19. Fracture processes and mechanisms of crack growth resistance in human enamel

    NASA Astrophysics Data System (ADS)

    Bajaj, Devendra; Park, Saejin; Quinn, George D.; Arola, Dwayne

    2010-07-01

    Human enamel has a complex micro-structure that varies with distance from the tooth’s outer surface. But contributions from the microstructure to the fracture toughness and the mechanisms of crack growth resistance have not been explored in detail. In this investigation the apparent fracture toughness of human enamel and the mechanisms of crack growth resistance were evaluated using the indentation fracture approach and an incremental crack growth technique. Indentation cracks were introduced on polished surfaces of enamel at selected distances from the occlusal surface. In addition, an incremental crack growth approach using compact tension specimens was used to quantify the crack growth resistance as a Junction of distance from the occlusal surface. There were significant differences in the apparent toughness estimated using the two approaches, which was attributed to the active crack length and corresponding scale of the toughening mechanisms.

  20. 77 FR 38024 - Oil and Gas; Well Stimulation, Including Hydraulic Fracturing, on Federal and Indian Lands

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-26

    ...On May 11, 2012, the Bureau of Land Management (BLM) published in the Federal Register a proposed rule to regulate hydraulic fracturing on public land and Indian land. The rule would require disclosure to the public of chemicals used in hydraulic fracturing on public land and Indian land, strengthen regulations related to well- bore integrity, and address issues related to flowback water. This rule is necessary to provide useful information to the public and to help ensure that hydraulic fracturing is conducted in a way that adequately protects the environment. Due to the complexity of the rule and the issues surrounding it, the BLM is extending the comment period for 60 days beyond the end of the initial comment period. As a result of this extension, the comment period will now close on September 10, 2012.

  1. Retrospective Analysis of Hanging Deaths in Ontario.

    PubMed

    Tugaleva, Elena; Gorassini, Donald R; Shkrum, Michael J

    2016-11-01

    Hanging deaths from investigation standpoint are rarely problematic. Unusual circumstances can on occasion raise suspicion of foul play. Associated neck injuries are reported in the literature with variable frequency (from 0% to 76.8%). This study retrospectively analyzed 755 hanging deaths in Ontario (Canada) to evaluate the demographic features and circumstances of hanging fatalities, and the frequency of hanging-related neck injuries. A number of cases showed unusual/special circumstances (e.g., complex, double suicides, restraints). Among 632 cases with complete autopsies, hyoid and larynx fractures were present in 46 cases (7.3%) with the most common being isolated hyoid fractures. The incidence of cricoid fractures was 0.5% and cervical spine injuries, 1.1%. A higher incidence of neck injuries occurred among males, long drop hangings, and in cases with complete suspension. There was a tendency for the number of fractures to increase with increasing age and weight of the deceased. © 2016 American Academy of Forensic Sciences.

  2. Spatial and layer-controlled variability in fracture networks

    NASA Astrophysics Data System (ADS)

    Procter, Andrew; Sanderson, David J.

    2018-03-01

    Topological sampling, based on 1) node counting and 2) circular sampling areas, is used to measure fracture intensity in surface exposures of a layered limestone/shale sequence in north Somerset, UK. This method provides similar levels of precision as more traditional line samples, but is about 10 times quicker and allows characterization of the network topology. Georeferencing of photographs of the sample sites allows later analysis of trace lengths and orientations, and identification of joint set development. ANOVA tests support a complex interaction of within-layer, between-layer and between-location variability in fracture intensity, with the different layers showing anomalous intensity at different locations. This variation is not simply due to bed thickness, nor can it be related to any obvious compositional or textural variation between the limestone beds. These results are used to assess approaches to the spatial mapping of fracture intensity.

  3. Phase-field modeling of fracture in variably saturated porous media

    NASA Astrophysics Data System (ADS)

    Cajuhi, T.; Sanavia, L.; De Lorenzis, L.

    2018-03-01

    We propose a mechanical and computational model to describe the coupled problem of poromechanics and cracking in variably saturated porous media. A classical poromechanical formulation is adopted and coupled with a phase-field formulation for the fracture problem. The latter has the advantage of being able to reproduce arbitrarily complex crack paths without introducing discontinuities on a fixed mesh. The obtained simulation results show good qualitative agreement with desiccation experiments on soils from the literature.

  4. Dual-porosity analysis of conservative tracer testing in saturated volcanic rocks at Yucca Mountain in Nye County, Nevada

    USGS Publications Warehouse

    Fahy, M.F.

    1997-01-01

    A radially convergent conservative tracer injection test was conducted between boreholes UE-25 #2 and UE-25 c #3 of the C-hole complex at Yucca Mountain to determine effective porosity and longitudinal dispersivity. Approximately 47% of the tracer mass was recovered and a dual-porosity analytical model replicates the breakthrough curve. Fractured-rock analyses focus on the fracture-porosity and geometry as the controlling factors in transport.

  5. The Effects of High Velocity Variable Mass Projectiles on the Maxillofacial Complex,

    DTIC Science & Technology

    1980-06-01

    mandibular joint and infra- temporal space. BOHYSICS DIVISION 4 . 4Figure 12: Two grain sphere impacted at 5637 fps into the right Zygoma. Green stick...impac- ted at mandibular symphy- sis, lateral view. Avulsion of anterior man- dible and fractures of maxilla and maxillary mol- ars are seen at A...Fractures of the coronoid process, Zygoma and articu- lar eminence are clearly evident. Multiple small fragments can be seen in the area of the temporo

  6. Novel Signs and Their Clinical Utility in Diagnosing Complex Regional Pain Syndrome (CRPS): A Prospective Observational Cohort Study.

    PubMed

    Kuttikat, Anoop; Shaikh, Maliha; Oomatia, Amin; Parker, Richard; Shenker, Nicholas

    2017-06-01

    Delays in diagnosis occur with complex regional pain syndrome (CRPS). We define and prospectively demonstrate that novel bedside tests measuring body perception disruption can identify patients with CRPS postfracture. The objectives of our study were to define and validate 4 bedside tests, to identify the prevalence of positive tests in patients with CRPS and other chronic pain conditions, and to assess the clinical utility (sensitivity, specificity, positive predictive value, negative predictive value) for identifying CRPS within a Fracture cohort. This was a single UK teaching hospital prospective cohort study with 313 recruits from pain-free volunteers and patients with chronic pain conditions.Four novel tests were Finger Perception (FP), Hand Laterality identification (HL), Astereognosis (AS), and Body Scheme (BS) report. Five questionnaires (Brief Pain Inventory, Upper Extremity Functional Index, Lower Extremity Functional Index, Neglect-like Symptom Questionnaire, Hospital Anxiety and Depression Score) assessed the multidimensional pain experience. FP and BS were the best performing tests. Prospective monitoring of fracture patients showed that out of 7 fracture patients (total n=47) who had both finger misperception and abnormal BS report at initial testing, 3 developed persistent pain with 1 having a formal diagnosis of CRPS. Novel signs are reliable, easy to perform, and present in chronic pain patients. FP and BS have significant clinical utility in predicting persistent pain in a fracture group thereby allowing targeted early intervention.

  7. Ankle fractures have features of an osteoporotic fracture.

    PubMed

    Lee, K M; Chung, C Y; Kwon, S S; Won, S H; Lee, S Y; Chung, M K; Park, M S

    2013-11-01

    We report the bone attenuation of ankle joint measured on computed tomography (CT) and the cause of injury in patients with ankle fractures. The results showed age- and gender-dependent low bone attenuation and low-energy trauma in elderly females, which suggest the osteoporotic features of ankle fractures. This study was performed to investigate the osteoporotic features of ankle fracture in terms of bone attenuation and cause of injury. One hundred ninety-four patients (mean age 51.0 years, standard deviation 15.8 years; 98 males and 96 females) with ankle fracture were included. All patients underwent CT examination, and causes of injury (high/low-energy trauma) were recorded. Mean bone attenuations of the talus, medial malleolus, lateral malleolus, and distal tibial metaphysis were measured on CT images. Patients were divided into younger age (<50 years) and older age (≥50 years) groups, and mean bone attenuation and causes of injury were compared between the two groups in each gender. Proportion of low-energy trauma was higher in the older age group than in the younger age group, but the difference was only significant in female gender (p = 0.011). The older age group showed significantly lower bone attenuation in the talus, medial malleolus, lateral malleolus, and distal tibial metaphysis than the younger age group in both genders. The older age group showed more complex pattern of fractures than the younger age group. With increasing age, bone attenuations tended to decrease and the difference of bone attenuation between the genders tended to increase in the talus, medial malleolus, lateral malleolus, and distal tibial metaphysis. Ankle fracture had features of osteoporotic fracture that is characterized by age- and gender-dependent low bone attenuation. Ankle fracture should not be excluded from the clinical and research interest as well as from the benefit of osteoporosis management.

  8. Characterization of the 3-D fracture setting of an unstable rock mass: From surface and seismic investigations to numerical modeling

    NASA Astrophysics Data System (ADS)

    Colombero, C.; Baillet, L.; Comina, C.; Jongmans, D.; Vinciguerra, S.

    2017-08-01

    The characterization of the fracturing state of a potentially unstable rock cliff is a crucial requirement for stability assessments and mitigation purposes. Classical measurements of fracture location and orientation can however be limited by inaccessible rock exposures. The steep topography and high-rise morphology of these cliffs, together with the widespread presence of fractures, can additionally condition the success of geophysical prospecting on these sites. In order to mitigate these limitations, an innovative approach combining noncontact geomechanical measurements, active and passive seismic surveys, and 3-D numerical modeling is proposed in this work to characterize the 3-D fracture setting of an unstable rock mass, located in NW Italian Alps (Madonna del Sasso, VB). The 3-D fracture geometry was achieved through a combination of field observations and noncontact geomechanical measurements on oriented pictures of the cliff, resulting from a previous laser-scanning and photogrammetric survey. The estimation of fracture persistence within the rock mass was obtained from surface active seismic surveys. Ambient seismic noise and earthquakes recordings were used to assess the fracture control on the site response. Processing of both data sets highlighted the resonance properties of the unstable rock volume decoupling from the stable massif. A finite element 3-D model of the site, including all the retrieved fracture information, enabled both validation and interpretation of the field measurements. The integration of these different methodologies, applied for the first time to a complex 3-D prone-to-fall mass, provided consistent information on the internal fracturing conditions, supplying key parameters for future monitoring purposes and mitigation strategies.

  9. Partial proximal tibia fractures

    PubMed Central

    Raschke, Michael J.; Kittl, Christoph; Domnick, Christoph

    2017-01-01

    Partial tibial plateau fractures may occur as a consequence of either valgus or varus trauma combined with a rotational and axial compression component. High-energy trauma may result in a more complex and multi-fragmented fracture pattern, which occurs predominantly in young people. Conversely, a low-energy mechanism may lead to a pure depression fracture in the older population with weaker bone density. Pre-operative classification of these fractures, by Müller AO, Schatzker or novel CT-based methods, helps to understand the fracture pattern and choose the surgical approach and treatment strategy in accordance with estimated bone mineral density and the individual history of each patient. Non-operative treatment may be considered for non-displaced intra-articular fractures of the lateral tibial condyle. Intra-articular joint displacement ⩾ 2 mm, open fractures or fractures of the medial condyle should be reduced and fixed operatively. Autologous, allogenic and synthetic bone substitutes can be used to fill bone defects. A variety of minimally invasive approaches, temporary osteotomies and novel techniques (e.g. arthroscopically assisted reduction or ‘jail-type’ screw osteosynthesis) offer a range of choices for the individual and are potentially less invasive treatments. Rehabilitation protocols should be carefully planned according to the degree of stability achieved by internal fixation, bone mineral density and other patient-specific factors (age, compliance, mobility). To avoid stiffness, early functional mobilisation plays a major role in rehabilitation. In the elderly, low-energy trauma and impression fractures are indicators for the further screening and treatment of osteoporosis. Cite this article: EFORT Open Rev 2017;2. DOI: 10.1302/2058-5241.2.160067. Originally published online at www.efortopenreviews.org PMID:28630761

  10. Magma fracturing and degassing associated with obsidian formation: The explosive–effusive transition

    USGS Publications Warehouse

    Cabrera, Agustin; Weinberg, Roberto; Wright, Heather M.

    2015-01-01

    This paper explores the role of melt fracturing in degassing rhyolitic volcanic systems. The Monte Pilato-Rocche Rosse eruptions in Italy evolved from explosive to effusive in style, and H2O content in quenched glasses changed over time from relatively H2O-rich (~ 0.90 wt.%) to H2O-poor dense obsidian (~ 0.10–0.20 wt.%). In addition, healed fractures have been recorded in all different eruptive materials, from the glass of early-erupted tube pumice and rinds of breadcrusted obsidian pyroclasts, to the glass of late-erupted dense obsidian pyroclasts, and throughout the final effusive Rocche Rosse lava flow. These rocks show multiple fault sets, some with crenulated fault planes indicating resumption of viscous flow after faulting, complex obsidian breccias with evidence for post-brecciation folding and stretching, and centimetre- to metre-thick tuffisite preserved in pyroclasts and lava, representing collapsed foam due to fracturing of vesicle walls. These microstructural observations indicate that multiple fracturing and healing events occurred during both explosive and effusive eruptions. H2O content in glass decreases by as much as 0.14 wt.% towards healed fractures/faults and decreases in stretched obsidian breccias towards regions of intense brecciation. A drop in pressure and/or increase in temperature along fractures caused diffusive H2O migration through melt towards fracture surfaces. Repetitive and pervasive fracturing and healing thereby create conditions for diffusive H2O loss into fractures and subsequent escape through permeable paths. This type of progressive magma degassing provides a potential mechanism to explain the formation of dense obsidian and the evolution from explosive to effusive eruption style.

  11. A systematic review of models used in cost-effectiveness analyses of preventing osteoporotic fractures.

    PubMed

    Si, L; Winzenberg, T M; Palmer, A J

    2014-01-01

    This review was aimed at the evolution of health economic models used in evaluations of clinical approaches aimed at preventing osteoporotic fractures. Models have improved, with medical continuance becoming increasingly recognized as a contributor to health and economic outcomes, as well as advancements in epidemiological data. Model-based health economic evaluation studies are increasingly used to investigate the cost-effectiveness of osteoporotic fracture preventions and treatments. The objective of this study was to carry out a systematic review of the evolution of health economic models used in the evaluation of osteoporotic fracture preventions. Electronic searches within MEDLINE and EMBASE were carried out using a predefined search strategy. Inclusion and exclusion criteria were used to select relevant studies. References listed of included studies were searched to identify any potential study that was not captured in our electronic search. Data on country, interventions, type of fracture prevention, evaluation perspective, type of model, time horizon, fracture sites, expressed costs, types of costs included, and effectiveness measurement were extracted. Seventy-four models were described in 104 publications, of which 69% were European. Earlier models focused mainly on hip, vertebral, and wrist fracture, but later models included multiple fracture sites (humerus, pelvis, tibia, and other fractures). Modeling techniques have evolved from simple decision trees, through deterministic Markov processes to individual patient simulation models accounting for uncertainty in multiple parameters. Treatment continuance has been increasingly taken into account in the models in the last decade. Models have evolved in their complexity and emphasis, with medical continuance becoming increasingly recognized as a contributor to health and economic outcomes. This evolution may be driven in part by the desire to capture all the important differentiating characteristics of medications under scrutiny, as well as the advancement in epidemiological data relevant to osteoporosis fractures.

  12. Non-Newtonian fluid flow in 2D fracture networks

    NASA Astrophysics Data System (ADS)

    Zou, L.; Håkansson, U.; Cvetkovic, V.

    2017-12-01

    Modeling of non-Newtonian fluid (e.g., drilling fluids and cement grouts) flow in fractured rocks is of interest in many geophysical and industrial practices, such as drilling operations, enhanced oil recovery and rock grouting. In fractured rock masses, the flow paths are dominated by fractures, which are often represented as discrete fracture networks (DFN). In the literature, many studies have been devoted to Newtonian fluid (e.g., groundwater) flow in fractured rock using the DFN concept, but few works are dedicated to non-Newtonian fluids.In this study, a generalized flow equation for common non-Newtonian fluids (such as Bingham, power-law and Herschel-Bulkley) in a single fracture is obtained from the analytical solutions for non-Newtonian fluid discharge between smooth parallel plates. Using Monte Carlo sampling based on site characterization data for the distribution of geometrical features (e.g., density, length, aperture and orientations) in crystalline fractured rock, a two dimensional (2D) DFN model is constructed for generic flow simulations. Due to complex properties of non-Newtonian fluids, the relationship between fluid discharge and the pressure gradient is nonlinear. A Galerkin finite element method solver is developed to iteratively solve the obtained nonlinear governing equations for the 2D DFN model. Using DFN realizations, simulation results for different geometrical distributions of the fracture network and different non-Newtonian fluid properties are presented to illustrate the spatial discharge distributions. The impact of geometrical structures and the fluid properties on the non-Newtonian fluid flow in 2D DFN is examined statistically. The results generally show that modeling non-Newtonian fluid flow in fractured rock as a DFN is feasible, and that the discharge distribution may be significantly affected by the geometrical structures as well as by the fluid constitutive properties.

  13. Microbially Induced Calcite Precipitation (MICP) - A Technology for Managing Flow and Transport in Porous and Fractured Media

    NASA Astrophysics Data System (ADS)

    Phillips, A. J.; Hiebert, R.; Kirksey, J.; Lauchnor, E. G.; Rothman, A.; Spangler, L.; Esposito, R.; Gerlach, R.; Cunningham, A. B.

    2014-12-01

    Certain microorganisms e.g., Sporosarcina pasteurii contribute enzymes that catalyze reactions which in the presence of calcium, can create saturation conditions favorable for calcium carbonate precipitation (microbially-induced calcium carbonate precipitation (MICP)). MICP can be used for a number of engineering applications including securing geologic storage of CO2 or other fluids by sealing fractures, improving wellbore integrity, and stabilizing fractured and unstable porous media. MICP treatment has the advantage of the use of small microorganisms, ~2μm, suggesting applicability to treatment of small aperture fractures not accessible to traditional treatments, for example the use of fine cement. The promotion of MICP in the subsurface is a complex reactive transport problem coupling microbial, abiotic (geochemical), geomechanical and hydrodynamic processes. In the laboratory, MICP has been demonstrated to cement together heavily fractured shale and reduce the permeability of fractures in shale and sandstone cores up to five orders of magnitude under both ambient and subsurface relevant pressure conditions (Figure 1). Most recently, a MICP fracture treatment field study was performed at a well at the Southern Company Gorgas Steam Generation Plant (Alabama) (Figure 1). The Fayetteville Sandstone at approximately 1120' below ground surface was hydraulically fractured prior to MICP treatment. After 4 days of injection of 24 calcium pulses and 6 microbial inoculations, injectivity of brine into the formation was significantly reduced. The experiment also resulted in a reduction in pressure decay which is a measure of improved wellbore integrity. These promising results suggest the potential for MICP treatment to seal fractured pathways at the field scale to improve the long-term security of geologically-stored carbon dioxide or prevent leakage of shale gas or hydraulic fracturing fluids into functional overlying aquifers, reducing environmental impacts.

  14. Streaming Potential Modeling to Understand the Identification of Hydraulically Active Fractures and Fracture-Matrix Fluid Interactions Using the Self-Potential Method

    NASA Astrophysics Data System (ADS)

    Jougnot, D.; Roubinet, D.; Linde, N.; Irving, J.

    2016-12-01

    Quantifying fluid flow in fractured media is a critical challenge in a wide variety of research fields and applications. To this end, geophysics offers a variety of tools that can provide important information on subsurface physical properties in a noninvasive manner. Most geophysical techniques infer fluid flow by data or model differencing in time or space (i.e., they are not directly sensitive to flow occurring at the time of the measurements). An exception is the self-potential (SP) method. When water flows in the subsurface, an excess of charge in the pore water that counterbalances electric charges at the mineral-pore water interface gives rise to a streaming current and an associated streaming potential. The latter can be measured with the SP technique, meaning that the method is directly sensitive to fluid flow. Whereas numerous field experiments suggest that the SP method may allow for the detection of hydraulically active fractures, suitable tools for numerically modeling streaming potentials in fractured media do not exist. Here, we present a highly efficient two-dimensional discrete-dual-porosity approach for solving the fluid-flow and associated self-potential problems in fractured domains. Our approach is specifically designed for complex fracture networks that cannot be investigated using standard numerical methods due to computational limitations. We then simulate SP signals associated with pumping conditions for a number of examples to show that (i) accounting for matrix fluid flow is essential for accurate SP modeling and (ii) the sensitivity of SP to hydraulically active fractures is intimately linked with fracture-matrix fluid interactions. This implies that fractures associated with strong SP amplitudes are likely to be hydraulically conductive, attracting fluid flow from the surrounding matrix.

  15. Trabecular fracture zone might not be the higher strain region of the trabecular framework

    NASA Astrophysics Data System (ADS)

    Tassani, Simone; Pani, Martino; Noailly, Jerome; Gonzalez Ballester, Miguel Angel

    2018-02-01

    Trabecular bone fracture is a traumatic and localized event studied worldwide in order to predict it. During the years researchers focussed over the mechanical characterization of the trabecular tissue to understand its mechanics. Several studies pointed out the very local nature of the trabecular failure, finally identifying the fracture zone with the aim to study it separately. The complexity of the three-dimensional trabecular framework and the local nature of the fracture event do not allow the direct evaluation of a single trabecula’s behaviour within its natural environment. For this reason, micro-Finite Element Modelling have been seen as the best way to investigate this biomechanical issue. Mechanical strain analysis is adopted in the literature for the identification of micro fracture using criteria based on principal strains. However, it was never verified if the fracture zone is actually the zone where principal strains are concentrated. Here we show how the maximum strain of the tissue might not be directly correlated to the fracture. In the present work a previously validated technique was used to identify the fracture zone of 10 trabecular specimen mechanically tested in compression and scanned in micro-CT before and after the mechanical test. Before-compression datasets were used to develop 10 micro-FE models were the same boundary conditions of the mechanical test were reproduced. Our results show how the known linear behaviour of the trabecular framework might not be directly related to the development of the fracture suggesting other non-linear phenomenon, like buckling or micro-damage, as actual cause of the traumatic event. This result might have several implications both in micro-modelling and in clinical applications for the study of fracture related pathology, like osteoporosis.

  16. Reliability of the pronator quadratus fat pad sign to predict the severity of distal radius fractures.

    PubMed

    Loesaus, Julia; Wobbe, Isabel; Stahlberg, Erik; Barkhausen, Joerg; Goltz, Jan Peter

    2017-09-28

    To evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity. Retrospectively we identified 89 consecutive patients (41 female, mean age 49 ± 18 years) who had X-ray (CR) and computed tomography (CT) within 24 h following distal forearm trauma. Thickness of pronator quadratus fat pad complex (PQC) was measured using lateral views (CR) and sagittal reconstructions (CT). Pearson's test was used to determine the correlation of the PQC thickness in CR and CT. A positive pronator quadratus sign (PQS) was defined as a PQC > 8.0 mm (female) or > 9.0 mm (male). Frykman classification was utilized to assess the severity of fractures. Forty-four/89 patients (49%) had a distal radius fracture (Frykman I n = 3, II n = 0, III n = 10, IV n = 5, V n = 2, VI n = 2, VII n = 9, VIII n = 13). Mean thickness of the PQC thickness can reliably be measured on X-ray views and was 7.5 ± 2.8 mm in lateral views (CR), respectively 9.4 ± 3.0 mm in sagittal reconstructions (CT), resulting in a significant correlation coefficient of 0.795. A positive PQS at CR was present in 21/44 patients (48%) with distal radius fracture and in 2/45 patients (4%) without distal radius fracture, resulting in a specificity of 96% and a sensitivity of 48% for the detection of distal radius fractures. There was no correlation between thickness of the PQC and severity of distal radius fractures. A positive PQS shows high specificity but low sensitivity for detection of distal radius fractures. The PQC thickness cannot predict the severity of distal radius fractures.

  17. Reliability of the pronator quadratus fat pad sign to predict the severity of distal radius fractures

    PubMed Central

    Loesaus, Julia; Wobbe, Isabel; Stahlberg, Erik; Barkhausen, Joerg; Goltz, Jan Peter

    2017-01-01

    AIM To evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity. METHODS Retrospectively we identified 89 consecutive patients (41 female, mean age 49 ± 18 years) who had X-ray (CR) and computed tomography (CT) within 24 h following distal forearm trauma. Thickness of pronator quadratus fat pad complex (PQC) was measured using lateral views (CR) and sagittal reconstructions (CT). Pearson’s test was used to determine the correlation of the PQC thickness in CR and CT. A positive pronator quadratus sign (PQS) was defined as a PQC > 8.0 mm (female) or > 9.0 mm (male). Frykman classification was utilized to assess the severity of fractures. RESULTS Forty-four/89 patients (49%) had a distal radius fracture (Frykman I n = 3, II n = 0, III n = 10, IV n = 5, V n = 2, VI n = 2, VII n = 9, VIII n = 13). Mean thickness of the PQC thickness can reliably be measured on X-ray views and was 7.5 ± 2.8 mm in lateral views (CR), respectively 9.4 ± 3.0 mm in sagittal reconstructions (CT), resulting in a significant correlation coefficient of 0.795. A positive PQS at CR was present in 21/44 patients (48%) with distal radius fracture and in 2/45 patients (4%) without distal radius fracture, resulting in a specificity of 96% and a sensitivity of 48% for the detection of distal radius fractures. There was no correlation between thickness of the PQC and severity of distal radius fractures. CONCLUSION A positive PQS shows high specificity but low sensitivity for detection of distal radius fractures. The PQC thickness cannot predict the severity of distal radius fractures. PMID:29098069

  18. Mechanics of slip and fracture along small faults and simple strike-slip fault zones in granitic rock

    NASA Astrophysics Data System (ADS)

    Martel, Stephen J.; Pollard, David D.

    1989-07-01

    We exploit quasi-static fracture mechanics models for slip along pre-existing faults to account for the fracture structure observed along small exhumed faults and small segmented fault zones in the Mount Abbot quadrangle of California and to estimate stress drop and shear fracture energy from geological field measurements. Along small strike-slip faults, cracks that splay from the faults are common only near fault ends. In contrast, many cracks splay from the boundary faults at the edges of a simple fault zone. Except near segment ends, the cracks preferentially splay into a zone. We infer that shear displacement discontinuities (slip patches) along a small fault propagated to near the fault ends and caused fracturing there. Based on elastic stress analyses, we suggest that slip on one boundary fault triggered slip on the adjacent boundary fault, and that the subsequent interaction of the slip patches preferentially led to the generation of fractures that splayed into the zones away from segment ends and out of the zones near segment ends. We estimate the average stress drops for slip events along the fault zones as ˜1 MPa and the shear fracture energy release rate during slip as 5 × 102 - 2 × 104 J/m2. This estimate is similar to those obtained from shear fracture of laboratory samples, but orders of magnitude less than those for large fault zones. These results suggest that the shear fracture energy release rate increases as the structural complexity of fault zones increases.

  19. Studying physical properties of deformed intact and fractured rocks by micro-scale hydro-mechanical-seismicity model

    NASA Astrophysics Data System (ADS)

    Raziperchikolaee, Samin

    The pore pressure variation in an underground formation during hydraulic stimulation of low permeability formations or CO2 sequestration into saline aquifers can induce microseismicity due to fracture generation or pre-existing fracture activation. While the analysis of microseismic data mainly focuses on mapping the location of fractures, the seismic waves generated by the microseismic events also contain information for understanding of fracture mechanisms based on microseismic source analysis. We developed a micro-scale geomechanics, fluid-flow and seismic model that can predict transport and seismic source behavior during rock failure. This model features the incorporation of microseismic source analysis in fractured and intact rock transport properties during possible rock damage and failure. The modeling method considers comprehensive grains and cements interaction through a bonded-particle-model. As a result of grain deformation and microcrack development in the rock sample, forces and displacements in the grains involved in the bond breakage are measured to determine seismic moment tensor. In addition, geometric description of the complex pore structure is regenerated to predict fluid flow behavior of fractured samples. Numerical experiments are conducted for different intact and fractured digital rock samples, representing various mechanical behaviors of rocks and fracture surface properties, to consider their roles on seismic and transport properties of rocks during deformation. Studying rock deformation in detail provides an opportunity to understand the relationship between source mechanism of microseismic events and transport properties of damaged rocks to have a better characterizing of fluid flow behavior in subsurface formations.

  20. Ball-joint versus single monolateral external fixators for definitive treatment of tibial shaft fractures.

    PubMed

    Beltsios, Michail; Mavrogenis, Andreas F; Savvidou, Olga D; Karamanis, Eirineos; Kokkalis, Zinon T; Papagelopoulos, Panayiotis J

    2014-07-01

    To compare modular monolateral external fixators with single monolateral external fixators for the treatment of open and complex tibial shaft fractures, to determine the optimal construct for fracture union. A total of 223 tibial shaft fractures in 212 patients were treated with a monolateral external fixator from 2005 to 2011; 112 fractures were treated with a modular external fixator with ball-joints (group A), and 111 fractures were treated with a single external fixator without ball-joints (group B). The mean follow-up was 2.9 years. We retrospectively evaluated the operative time for fracture reduction with the external fixator, pain and range of motion of the knee and ankle joints, time to union, rate of malunion, reoperations and revisions of the external fixators, and complications. The time for fracture reduction was statistically higher in group B; the rate of union was statistically higher in group B; the rate of nonunion was statistically higher in group A; the mean time to union was statistically higher in group A; the rate of reoperations was statistically higher in group A; and the rate of revision of the external fixator was statistically higher in group A. Pain, range of motion of the knee and ankle joints, rates of delayed union, malunion and complications were similar. Although modular external fixators are associated with faster intraoperative fracture reduction with the external fixator, single external fixators are associated with significantly better rates of union and reoperations; the rates of delayed union, malunion and complications are similar.

  1. ThMYC4E, candidate Blue aleurone 1 gene controlling the associated trait in Triticum aestivum

    PubMed Central

    Chen, Wenjie; Zhang, Bo; Wang, Daowen; Liu, Dengcai; Zhang, Huaigang

    2017-01-01

    Blue aleurone is a useful and interesting trait in common wheat that was derived from related species. Here, transcriptomes of blue and white aleurone were compared for isolating Blue aleurone 1 (Ba1) transferred from Thinopyrum ponticum. In the genes involved in anthocyanin biosynthesis, only a basic helix-loop-helix (bHLH) transcription factor, ThMYC4E, had a higher transcript level in blue aleurone phenotype, and was homologous to the genes on chromosome 4 of Triticum aestivum. ThMYC4E carried the characteristic domains (bHLH-MYC_N, HLH and ACT-like) of a bHLH transcription factor, and clustered with genes regulating anthocyanin biosynthesis upon phylogenetic analysis. The over-expression of ThMYC4E regulated anthocyanin biosynthesis with the coexpression of the MYB transcription factor ZmC1 from maize. ThMYC4E existed in the genomes of the addition, substitution and near isogenic lines with the blue aleurone trait derived from Th. ponticum, and could not be detected in any germplasm of T. urartu, T. monococcum, T. turgidum, Aegilops tauschii or T. aestivum, with white aleurone. These results suggested that ThMYC4E was candidate Ba1 gene controlling the blue aleurone trait in T. aestivum genotypes carrying Th. ponticum introgression. The ThMYC4E isolation aids in better understanding the genetic mechanisms of the blue aleurone trait and in its more effective use during wheat breeding. PMID:28704468

  2. Genome-wide Association Study for Radiographic Vertebral Fractures: A Potential Role for the 16q24 BMD Locus versus Lessons Learned from Challenging Phenotype Definition.

    PubMed

    Oei, Ling; Estrada, Karol; Duncan, Emma L; Christiansen, Claus; Liu, Ching-Ti; Langdahl, Bente L; Obermayer-Pietsch, Barbara; Riancho, José A; Prince, Richard L; van Schoor, Natasja M; McCloskey, Eugene; Hsu, Yi-Hsiang; Evangelou, Evangelos; Ntzani, Evangelia; Evans, David M; Alonso, Nerea; Husted, Lise B; Valero, Carmen; Hernandez, Jose L; Lewis, Joshua R; Kaptoge, Stephen K; Zhu, Kun; Cupples, L Adrienne; Medina-Gómez, Carolina; Vandenput, Liesbeth; Kim, Ghi Su; Lee, Seung Hun; Castaño-Betancourt, Martha C; Oei, Edwin H G; Martinez, Josefina; Daroszewska, Anna; van der Klift, Marjolein; Mellström, Dan; Herrera, Lizbeth; Karlsson, Magnus K; Hofman, Albert; Ljunggren, Osten; Pols, Huibert A P; Stolk, Lisette; van Meurs, Joyce B J; Ioannidis, John P A; Zillikens, M Carola; Lips, Paul; Karasik, David; Uitterlinden, André G; Styrkarsdottir, Unnur; Brown, Matthew A; Koh, Jung-Min; Richards, J Brent; Reeve, Jonathan; Ohlsson, Claes; Ralston, Stuart H; Kiel, Douglas P; Rivadeneira, Fernando

    2013-10-25

    Vertebral fracture risk is a heritable complex trait. The aim of this study was to identify genetic susceptibility factors for osteoporotic vertebral fractures applying a genome-wide association study (GWAS) approach. The GWAS discovery was based on the Rotterdam Study, a population-based study of elderly Dutch individuals aged >55years; and comprising 329 cases and 2,666 controls with radiographic scoring (McCloskey-Kanis) and genetic data. Replication of one top-associated SNP was pursued by de-novo genotyping of 15 independent studies across Europe, the United States, Australia and one Asian study. Radiographic vertebral fracture assessment was performed using McCloskey-Kanis or Genant semi-quantitative definitions. SNPs were analyzed in relation to vertebral fracture using logistic regression models corrected for age and sex. Fixed effects inverse variance and Han-Eskin alternative random effects meta-analyses were applied. Genome-wide significance was set at P<5x10 -8 . In the discovery, a SNP (rs11645938) on chromosome 16q24 was associated with the risk for vertebral fractures at p=4.6 x 10 -8 . However, the association was not significant across 5,720 cases and 21,791 controls from 14 studies. Fixed-effects meta analyses summary estimate was 1.06 (95% CI: 0.98-1.14; P=0.17), displaying high degree of heterogeneity (I 2 =57%; Qhet p= 0.0006). Under Han-Eskin alternative random effects model the summary effect was significant (P=0.0005). The SNP maps to a region previously found associated with lumbar spine bone mineral density (LS-BMD) in two large meta-analyses from the GEFOS consortium. A false positive association in the GWAS discovery cannot be excluded, yet, the low-powered setting of the discovery and replication settings (appropriate to identify risk effect size > 1.25) may still be consistent with an effect size <1.10, more of the type expected in complex traits. Larger effort in studies with standardized phenotype definitions are needed to confirm or reject the involvement of this locus on the risk for vertebral fractures. © 2013.

  3. Genome-wide association study for radiographic vertebral fractures: A potential role for the 16q24 BMD locus

    PubMed Central

    Oei, Ling; Estrada, Karol; Duncan, Emma L.; Christiansen, Claus; Liu, Ching-Ti; Langdahl, Bente L.; Obermayer-Pietsch, Barbara; Riancho, José A.; Prince, Richard L.; van Schoor, Natasja M.; McCloskey, Eugene; Hsu, Yi-Hsiang; Evangelou, Evangelos; Ntzani, Evangelia; Evans, David M.; Alonso, Nerea; Husted, Lise B.; Valero, Carmen; Hernandez, Jose L.; Lewis, Joshua R.; Kaptoge, Stephen K.; Zhu, Kun; Cupples, L. Adrienne; Medina-Gómez, Carolina; Vandenput, Liesbeth; Kim, Ghi Su; Lee, Seung Hun; Castaño-Betancourt, Martha C.; Oei, Edwin H.G.; Martinez, Josefina; Daroszewska, Anna; van der Klift, Marjolein; Mellström, Dan; Herrera, Lizbeth; Karlsson, Magnus K.; Hofman, Albert; Ljunggren, Östen; Pols, Huibert A.P.; Stolk, Lisette; van Meurs, Joyce B.J.; Ioannidis, John P.A.; Zillikens, M. Carola; Lips, Paul; Karasik, David; Uitterlinden, André G.; Styrkarsdottir, Unnur; Brown, Matthew A.; Koh, Jung-Min; Richards, J. Brent; Reeve, Jonathan; Ohlsson, Claes; Ralston, Stuart H.; Kiel, Douglas P.; Rivadeneira, Fernando

    2014-01-01

    Vertebral fracture risk is a heritable complex trait. The aim of this study was to identify genetic susceptibility factors for osteoporotic vertebral fractures applying a genome-wide association study (GWAS) approach. The GWAS discovery was based on the Rotterdam Study, a population-based study of elderly Dutch individuals aged >55years; and comprising 329 cases and 2666 controls with radiographic scoring (McCloskey–Kanis) and genetic data. Replication of one top-associated SNP was pursued by de-novo genotyping of 15 independent studies across Europe, the United States, and Australia and one Asian study. Radiographic vertebral fracture assessment was performed using McCloskey–Kanis or Genant semi-quantitative definitions. SNPs were analyzed in relation to vertebral fracture using logistic regression models corrected for age and sex. Fixed effects inverse variance and Han–Eskin alternative random effects meta-analyses were applied. Genome-wide significance was set at p < 5 × 10−8. In the discovery, a SNP (rs11645938) on chromosome 16q24 was associated with the risk for vertebral fractures at p=4.6×10−8. However, the association was not significant across 5720 cases and 21,791 controls from 14 studies. Fixed-effects meta-analysis summary estimate was 1.06 (95% CI: 0.98–1.14; p = 0.17), displaying high degree of heterogeneity (I2=57%; Qhet p =0.0006). Under Han–Eskin alternative random effects model the summary effect was significant (p = 0.0005). The SNP maps to a region previously found associated with lumbar spine bone mineral density (LS-BMD) in two large meta-analyses from the GEFOS consortium. A false positive association in the GWAS discovery cannot be excluded, yet, the low-powered setting of the discovery and replication settings (appropriate to identify risk effect size >1.25) may still be consistent with an effect size <1.10, more of the type expected in complex traits. Larger effort in studies with standardized phenotype definitions is needed to confirm or reject the involvement of this locus on the risk for vertebral fractures. PMID:24516880

  4. Modeling the complex shape evolution of sedimenting particle swarms in fractures

    NASA Astrophysics Data System (ADS)

    Mitchell, C. A.; Nitsche, L.; Pyrak-Nolte, L. J.

    2016-12-01

    The flow of micro- and nano-particles through subsurface systems can occur in several environments, such as hydraulic fracturing or enhanced oil recovery. Computer simulations were performed to advance our understanding of the complexity of subsurface particle swarm transport in fractures. Previous experiments observed that particle swarms in fractures with uniform apertures exhibit enhanced transport speeds and suppressed bifurcations for an optimal range of apertures. Numerical simulations were performed for low Reynolds number, no interfacial tension and uniform viscosity conditions with particulate swarms represented by point-particles that mutually interact through their (regularized) Stokeslet fields. A P3 M technique accelerates the summations for swarms exceeding 105 particles. Fracture wall effects were incorporated using a least-squares variant of the method of fundamental solutions, with grid mapping of the surface force and source elements within the fast-summation scheme. The numerical study was executed on the basis of dimensionless variables and parameters, in the interest of examining the fundamental behavior and relationships of particle swarms in the presence of uniform apertures. Model parameters were representative of particle swarms experiments to enable direct comparison of the results with the experimental observations. The simulations confirmed that the principal phenomena observed in the experiments can be explained within the realm of Stokes flow. The numerical investigation effectively replicated swarm evolution in a uniform fracture and captured the coalescence, torus and tail formation, and ultimate breakup of the particle swarm as it fell under gravity in a quiescent fluid. The rate of swarm evolution depended on the number of particles in a swarm. When an ideal number of particles was used, swarm transport was characterized by an enhanced velocity regime as observed in the laboratory data. Understanding the physics particle swarms in fractured media will improve the ability to perform controlled micro-particulate transport through rock. Acknowledgment: This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Geosciences Research Program under Award Number (DE-FG02-09ER16022).

  5. [Missed diagnosis of osteoporosis and failure to treat adults with hip fracture in Chile].

    PubMed

    Rodríguez, José Adolfo; Borzutzky, Arturo; Barnett, Carolina; Marín, Pedro Paulo

    2003-07-01

    Hip fractures are the most severe complication of osteoporosis, yet patients who suffer hip fracture rarely receive adequate treatment. To assess diagnosis and treatment of osteoporosis in patients with hip fracture. A retrospective study in 203 patients admitted for hip fracture surgery at two medical institutions in Santiago, Chile. Clinical data from 101 patients from the Hospital Clínico Pontificia Universidad Católica de Chile (a university tertiary care hospital, HCPUC) and 102 patients from Hospital de Urgencia de la Asistencia Pública (a public emergency hospital, HUAP) were reviewed. We also evaluated incidence of new fractures, further treatment of osteoporosis and functionality, by means of a telephonic survey of 48% of patients (n = 99) 12.3 +/- 5.3 months after hip fracture in HCPUC and 16.5 +/- 3.0 months for HUAP. A previous diagnosis of osteoporosis was present in 2.9% and 1% of cases, and treatment prior to fracture in 3.9% and 0% of cases from HCPUC and HUAP, respectively. None of the patients in HUAP were diagnosed with osteoporosis during hospital stay or given treatment for this condition at discharge, in comparison to 0.9% (n = 1) and 2% (n = 2), respectively, in HCPUC. Seven and six percent of cases presented prior hip fractures. Telephonic follow up of patients revealed that 75.6% persisted without treatment for osteoporosis. At follow up, 2.9% and 3% of patients in HCPUC and HUAP had presented new hip fractures. At the time of survey 30.9% and 34% of patients, respectively, were considered invalid. Missed diagnosis and failure to treat osteoporosis occurred in over 90% of patients admitted for hip fracture, regardless of the different complexities in the hospitals of admission. The data suggest that lack of medical action on these issues may play a role in failure to prevent new hip fractures.

  6. Ground penetrating radar for fracture mapping in underground hazardous waste disposal sites: A case study from an underground research tunnel, South Korea

    NASA Astrophysics Data System (ADS)

    Baek, Seung-Ho; Kim, Seung-Sep; Kwon, Jang-Soon; Um, Evan Schankee

    2017-06-01

    Secure disposal or storage of nuclear waste within stable geologic environments hinges on the effectiveness of artificial and natural radiation barriers. Fractures in the bedrock are viewed as the most likely passage for the transport of radioactive waste away from a disposal site. We utilize ground penetrating radar (GPR) to map fractures in the tunnel walls of an underground research tunnel at the Korea Atomic Energy Research Institute (KAERI). GPR experiments within the KAERI Underground Research Tunnel (KURT) were carried out by using 200 MHz, 500 MHz, and 1000 MHz antennas. By using the high-frequency antennas, we were able to identify small-scale fractures, which were previously unidentified during the tunnel excavation process. Then, through 3-D visualization of the grid survey data, we reconstructed the spatial distribution and interconnectivity of the multi-scale fractures within the wall. We found that a multi-frequency GPR approach provided more details of the complex fracture network, including deep structures. Furthermore, temporal changes in reflection polarity between the GPR surveys enabled us to infer the hydraulic characteristics of the discrete fracture network developed behind the surveyed wall. We hypothesized that the fractures exhibiting polarity change may be due to a combination of air-filled and mineralogical boundaries. Simulated GPR scans for the considered case were consistent with the observed GPR data. If our assumption is correct, the groundwater flow into these near-surface fractures may form the water-filled fractures along the existing air-filled ones and hence cause the changes in reflection polarity over the given time interval (i.e., 7 days). Our results show that the GPR survey is an efficient tool to determine fractures at various scales. Time-lapse GPR data may be essential to characterize the hydraulic behavior of discrete fracture networks in underground disposal facilities.

  7. Elbow dislocation with intra-articular fracture: the results of operative treatment without repair of the medial collateral ligament.

    PubMed

    Forthman, Christopher; Henket, Marjolijn; Ring, David C

    2007-10-01

    To determine the effectiveness of a protocol for the treatment of fracture-dislocations of the elbow based on the concept that, if dislocation of the elbow with associated fractures can be made to resemble a simple elbow dislocation by repairing or reconstructing the fractured structures, repair of the medial collateral ligament (MCL) will not be necessary. Over a 5-year period, a single surgeon operated on 34 patients with a posterior dislocation of the elbow associated with one or more intra-articular fractures. The mean age of these 19 men and 15 women was 48 years. Associated fractures included the capitellum, trochlea, and lateral epicondyle in 3 patients; the olecranon in 1 patient; and the radial head in 30 patients (with concomitant fracture of the coronoid process-the so-called "terrible triad" of the elbow-in 22 patients, and concomitant fracture of the coronoid and olecranon in 1 patient). Operative treatment consisted of open reduction internal fixation (ORIF) or prosthetic replacement of all fractures and reattachment of the origin of the lateral collateral ligament (LCL) complex to the lateral epicondyle. The MCL was not repaired. Two patients (1 with a terrible triad injury and 1 with fracture of the capitellum and trochlea) had postoperative instability related to noncompliance, had reconstructive procedures, and were considered failures. An average of 32 months after injury, the remaining 32 patients regained an average of 120 degrees ulnohumeral motion and 142 degrees forearm rotation. Twenty-five of 34 patients (74%) had good or excellent results according to the system of Broberg and Morrey. Patients with terrible triad injuries had an average of 117 degrees ulnohumeral motion and 137 degrees forearm rotation, and 17 of 22 patients (77%) had good or excellent results. MCL repair is unnecessary in the treatment of dislocation of the elbow with associated intra-articular fractures, provided that the articular fractures and the LCL are repaired or reconstructed.

  8. Shock-induced kelyphite formation in the core of a complex impact crater

    NASA Astrophysics Data System (ADS)

    Deseta, Natalie; Boonsue, Suporn; Gibson, Roger L.; Spray, John G.

    2017-10-01

    We present a compositional and textural analysis of shock-induced microtextures in garnet porphyroblasts in migmatitic garnet-cordierite-biotite paragneisses from the centre of the Vredefort impact structure, South Africa. Detailed imaging and major element analysis of deformation features in, and adjacent to, the garnet porphyroblasts record a complex, heterogeneous distribution of shock effects at the microscale. As the most competent silicate mineral in the assemblage, with the highest Hugoniot Elastic Limit and a wide pressure-temperature stability field, the porphyroblastic garnet preserves a more diverse shock deformation response compared to minerals such as quartz and feldspar, which underwent more comprehensive shock metamorphism and subsequent annealing. The garnet porphyroblasts display pre-impact fractures that are overprinted by later intra-granular Hertzian and distinctive planar fractures associated with the impact event. Shock-induced strain localization occurred along internal slip planes and defects, including pre-existing fractures and inclusion boundaries in the garnet. Symplectitic (kelyphitic) coronas commonly enclose the garnet porphyroblasts, and inhabit intra-granular fractures. The kelyphite assemblage in fractures with open communication beyond garnet grain boundaries is characterized by orthopyroxene—cordierite—sapphirine. Conversely, the kelyphite assemblage in closed-off intra-granular fractures is highly variable, comprising spatially restricted combinations of a secondary garnet phase with a majoritic component, Al-rich orthopyroxene, sapphirine and cordierite. The impedance contrast between garnet porphyroblasts and their inclusions further facilitated the formation of shock-induced features (Al-rich orthopyroxene coronas). Together, the textural and mineralogical data suggest that these features provide a record of oscillatory shock perturbations initiated under confining pressure beneath the transient crater floor. This occurred as the shocked rock volume underwent post-shock expansion, forming the core of the central uplift, and was followed by variable textural re-equilibration. This study thus provides a microtextural and mineralogical perspective of the shock regime within confined crust immediately prior to and during central uplift formation.

  9. The advantages of advanced computer-assisted diagnostics and three-dimensional preoperative planning on implant position in orbital reconstruction.

    PubMed

    Jansen, Jesper; Schreurs, Ruud; Dubois, Leander; Maal, Thomas J J; Gooris, Peter J J; Becking, Alfred G

    2018-04-01

    Advanced three-dimensional (3D) diagnostics and preoperative planning are the first steps in computer-assisted surgery (CAS). They are an integral part of the workflow, and allow the surgeon to adequately assess the fracture and to perform virtual surgery to find the optimal implant position. The goal of this study was to evaluate the accuracy and predictability of 3D diagnostics and preoperative virtual planning without intraoperative navigation in orbital reconstruction. In 10 cadaveric heads, 19 complex orbital fractures were created. First, all fractures were reconstructed without preoperative planning (control group) and at a later stage the reconstructions were repeated with the help of preoperative planning. Preformed titanium mesh plates were used for the reconstructions by two experienced oral and maxillofacial surgeons. The preoperative virtual planning was easily accessible for the surgeon during the reconstruction. Computed tomographic scans were obtained before and after creation of the orbital fractures and postoperatively. Using a paired t-test, implant positioning accuracy (translation and rotations) of both groups were evaluated by comparing the planned implant position with the position of the implant on the postoperative scan. Implant position improved significantly (P < 0.05) for translation, yaw and roll in the group with preoperative planning (Table 1). Pitch did not improve significantly (P = 0.78). The use of 3D diagnostics and preoperative planning without navigation in complex orbital wall fractures has a positive effect on implant position. This is due to a better assessment of the fracture, the possibility of virtual surgery and because the planning can be used as a virtual guide intraoperatively. The surgeon has more control in positioning the implant in relation to the rim and other bony landmarks. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Radiographic and functional evaluation of low profile dorsal versus volar plating for distal radius fractures.

    PubMed

    Kumar, Sanjay; Khan, A N; Sonanis, S V

    2016-12-01

    Fracture of the distal radius is a common clinical problem. Complex fracture requires open reduction and stabilization with plating to restore anatomy. Dorsal plating has advantages of buttressing the fracture better but often complicated with tendon problems as per literature. The rate of complications however, was not compared between the low-profile dorsal and the volar plates. This was a retrospective study on seventy one patients with dorsally angulated or displaced distal radius fractures, who underwent fixation of fractures with either dorsal or volar locking plate from Jan - Nov 2012. Preoperative radiographs were classified based on Universal and Fernandez classification. Postoperative radiographs were assessed for anatomical restoration of Radial length, radial inclination and volar tilt. Tendon and nerve related complications were assessed and functional evaluation was performed on the basis of PRWE (Patient related wrist evaluation) score. Both groups were matched for their demographic profile and fracture types (p 0.033). Dorsal plating group had 89% excellent/good restoration and fair in 11%. Volar group had 96% excellent/good restoration and fair in 4%. Statistical analysis was performed with unpaired t test for radiographic parameters. Three patients had tendon related complications in dorsal plating group; two patients in volar group had nerve related complications. Functional outcome with PRWE was comparable between two groups. Results with low profile dorsal plating were comparable to volar plating. Therefore dorsal plating can be used as an alternative method when dorsal buttressing of comminuted fracture is required, especially with concomitant osteoporosis.

  11. A scoping review of biomechanical testing for proximal humerus fracture implants.

    PubMed

    Cruickshank, David; Lefaivre, Kelly A; Johal, Herman; MacIntyre, Norma J; Sprague, Sheila A; Scott, Taryn; Guy, Pierre; Cripton, Peter A; McKee, Michael; Bhandari, Mohit; Slobogean, Gerard P

    2015-07-30

    Fixation failure is a relatively common sequela of surgical management of proximal humerus fractures (PHF). The purpose of this study is to understand the current state of the literature with regard to the biomechanical testing of proximal humerus fracture implants. A scoping review of the proximal humerus fracture literature was performed, and studies testing the mechanical properties of a PHF treatment were included in this review. Descriptive statistics were used to summarize the characteristics and methods of the included studies. 1,051 proximal humerus fracture studies were reviewed; 67 studies met our inclusion criteria. The most common specimen used was cadaver bone (87%), followed by sawbones (7%) and animal bones (4%). A two-part fracture pattern was tested most frequently (68%), followed by three-part (23%), and four-part (8%). Implants tested included locking plates (52%), intramedullary devices (25%), and non-locking plates (25%). Hemi-arthroplasty was tested in 5 studies (7%), with no studies using reverse total shoulder arthroplasty (RTSA) implants. Torque was the most common mode of force applied (51%), followed by axial loading (45%), and cantilever bending (34%). Substantial testing diversity was observed across all studies. The biomechanical literature was found to be both diverse and heterogeneous. More complex fracture patterns and RTSA implants have not been adequately tested. These gaps in the current literature will need to be addressed to ensure that future biomechanical research is clinically relevant and capable of improving the outcomes of challenging proximal humerus fracture patterns.

  12. The pediatric mandible: II. Management of traumatic injury or fracture.

    PubMed

    Smartt, James M; Low, David W; Bartlett, Scott P

    2005-08-01

    After studying this article, the participant should be able to: 1. Describe the changing epidemiology of mandibular fractures in children and adolescents. 2. Discuss the appropriate use of internal fixation in the treatment of pediatric mandibular fractures. 3. Describe the difficulties posed by the deciduous dentition in the use of interdental wiring. 4. Understand reasons why techniques specific to adult fractures may not be applicable to the growing mandible. 5. Understand the etiology and epidemiology of pediatric mandibular fractures. 6. Understand the reasons for conservative (closed) versus aggressive (open) treatment of mandibular injury. Fractures of the pediatric mandible are complicated by the anatomic complexity of the developing mandible, particularly by the presence of tooth buds and the eruption of deciduous and permanent teeth. Traditional methods of fracture reduction and fixation employed in adults have little applicability in the pediatric population. The authors describe the surgical techniques that have been used at their institution and those that can be used safely in the pediatric setting. In most cases, "conservative" management is the preferred option, especially in the treatment of condylar fractures. In cases requiring surgical intervention, interdental wiring, drop wires in combination with circummandibular wires, and acrylic splints are suited well to specific phases of dental maturation. Open reduction and internal fixation using monocortical screws and microplates or resorbable plates and screws are acceptable techniques in the pediatric patient, but they require special safeguards. Algorithms are presented to simplify management of these complicated injuries.

  13. Fracture and damage evolution of fluorinated polymers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, E. N.; Rae, P.; Orler, E. B.

    2004-01-01

    Fluoropolymers are often semi-crystalline in nature, with their linear chains forming complicated phases near room temperature and ambient pressure. The most widely used fluorocarbon polymer for engineering applications is polytetrafluoroethylene (PTFE), due to its extremely low coefficient of friction, outstanding resistance to corrosion, and excellent electrical properties. The phase structure of PTFE is complex with four well-characterized crystalline phases (three observed at atmospheric pressure) and substantial molecular motion well below the melting point. The first-order transition at 19 C between phases II and IV is an unraveling in the helical conformation. Further rotational disordering and untwisting of the helices occursmore » above 30 C giving way to phase I. The mechanical behavior, including fracture and damage evolution, of PTFE depends on the chain and segment motions dictated by crystalline phase microstructure. The presence of three unique phases at ambient pressure near room temperature implies that failure during standard operating conditions may be strongly dependent on the phase. This paper presents a preliminary study of fracture and damage evolution in PTFE with the effects of temperature-induced phase on fracture mechanisms. The quasi-static fracture of PTFE in the atmospheric pressure regime, over a range of temperatures, was found to be strongly phase dependent: phase II exhibits brittle-fracture, phase IV displays ductile-fracture with crazing and some stable crack growth, and plastic flow dominates phase 1. The bulk failure properties are correlated to failure mechanisms through fractography of the fracture surfaces (optical microscopy and scanning electron microscopy (SEM)).« less

  14. Mechanisms of boron removal from hydraulic fracturing wastewater by aluminum electrocoagulation.

    PubMed

    Sari, Mutiara Ayu; Chellam, Shankararaman

    2015-11-15

    Boron uptake from highly saline hydraulic fracturing wastewater by freshly precipitated amorphous Al(OH)3 precipitates is due to ligand exchange and complexation with surface hydroxyl groups. Consequently, aluminum electrocoagulation can be a feasible approach to remove boron from flowback/produced water. Actual hydraulic fracturing wastewater containing ∼120mg/L boron from the Eagle Ford shale play was employed. Electrocoagulation was performed over a range of aluminum dosages (0-1350mg/L), pH 6.4 and 8, and high current densities (20-80mA/cm(2)) using a cylindrical aluminum anode encompassed by a porous cylindrical 316-stainless steel cathode. Direct measurements of boron uptake along with its chemical state and coordination were made using Attenuated Total Reflection-Fourier Transform Infrared spectroscopy (ATR-FTIR) and X-Ray Photoelectron Spectroscopy. Boron removal increased monotonically with aluminum dosage and was higher at pH 8, but remained relatively constant at ⩾20mA/cm(2). Chloride ions induced anodic pitting and super-Faradaic (131% efficiency) aluminum dissolution and their electrooxidation produced free chlorine. ATR-FTIR suggested outer-sphere and inner-sphere complexation of trigonal B(OH)3 with Al(OH)3, which was confirmed by the BO bond shifting toward lower binding energies in XPS. Severe AlO interferences precluded evidence for tetrahedral B(OH)4(-) complexation. No evidence for co-precipitation was obtained. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Capturing poromechanical coupling effects of the reactive fracturing process in porous rock via a DEM-network model

    NASA Astrophysics Data System (ADS)

    Ulven, Ole Ivar; Sun, WaiChing

    2016-04-01

    Fluid transport in a porous medium has important implications for understanding natural geological processes. At a sufficiently large scale, a fluid-saturated porous medium can be regarded as a two-phase continuum, with the fluid constituent flowing in the Darcian regime. Nevertheless, a fluid mediated chemical reaction can in some cases change the permeability of the rock locally: Mineral dissolution can cause increased permeability, whereas mineral precipitation can reduce the permeability. This might trigger a complicated hydro-chemo-mechanical coupling effect that causes channeling of fluids or clogging of the system. If the fluid is injected or produced at a sufficiently high rate, the pressure might increase enough to cause the onset and propagation of fractures. Fractures in return create preferential flow paths that enhance permeability, localize fluid flow and chemical reaction, prevent build-up of pore pressure and cause anisotropy of the hydro-mechanical responses of the effective medium. This leads to a complex coupled process of solid deformation, chemical reaction and fluid transport enhanced by the fracture formation. In this work, we develop a new coupled numerical model to study the complexities of feedback among fluid pressure evolution, fracture formation and permeability changes due to a chemical process in a 2D system. We combine a discrete element model (DEM) previously used to study a volume expanding process[1, 2] with a new fluid transport model based on poroelasticity[3] and a fluid-mediated chemical reaction that changes the permeability of the medium. This provides new insights into the hydro-chemo-mechanical process of a transforming porous medium. References [1] Ulven, O. I., Storheim, H., Austrheim, H., and Malthe-Sørenssen, A. "Fracture Initiation During Volume Increasing Reactions in Rocks and Applications for CO2 Sequestration", Earth Planet. Sc. Lett. 389C, 2014a, pp. 132 - 142, doi:10.1016/j.epsl.2013.12.039. [2] Ulven, O. I., Jamtveit, B., and Malthe-Sørenssen, A., "Reaction-driven fracturing of porous rock", J. Geophys. Res. Solid Earth 119, 2014b, doi:10.1002/2014JB011102. [3] Ulven, O. I., and Sun, W.C., "A locally mass-conserving dual-graph lattice model for fluid-driven fracture", in prep.

  16. Monolithic ceramic analysis using the SCARE program

    NASA Technical Reports Server (NTRS)

    Manderscheid, Jane M.

    1988-01-01

    The Structural Ceramics Analysis and Reliability Evaluation (SCARE) computer program calculates the fast fracture reliability of monolithic ceramic components. The code is a post-processor to the MSC/NASTRAN general purpose finite element program. The SCARE program automatically accepts the MSC/NASTRAN output necessary to compute reliability. This includes element stresses, temperatures, volumes, and areas. The SCARE program computes two-parameter Weibull strength distributions from input fracture data for both volume and surface flaws. The distributions can then be used to calculate the reliability of geometrically complex components subjected to multiaxial stress states. Several fracture criteria and flaw types are available for selection by the user, including out-of-plane crack extension theories. The theoretical basis for the reliability calculations was proposed by Batdorf. These models combine linear elastic fracture mechanics (LEFM) with Weibull statistics to provide a mechanistic failure criterion. Other fracture theories included in SCARE are the normal stress averaging technique and the principle of independent action. The objective of this presentation is to summarize these theories, including their limitations and advantages, and to provide a general description of the SCARE program, along with example problems.

  17. Study on fracturing flowback fluid treatment technology for shale gas in Yangzhou

    NASA Astrophysics Data System (ADS)

    Shi, Shengwei; Du, Jiajia; Kang, Dingyu; Chen, Xinjian; Qu, Chengtun; Yu, Tao

    2018-02-01

    Shale gas fracturing flowback fluid has the characteristics of high viscosity, large displacement, complex components and difficult to deal with. Therefore, it is of great significance for environmental protection to treat and reuse it. In this paper, Yangzhou shale gas is taken as an object to study the treatment of shale gas fracturing flowback fluid. The results shown that the viscosity of the fracturing flowback fluid before treatment was 16.75mPa·s, and when the pH was adjusted to 3.5, with Cerium(III) sulfate and ferrous sulfate as catalyst and the dosage were 60mg/L and 120 mg/L respectively, and hydrogen peroxide dosage was 0.5%, the viscosity of fracturing folwback fluid was reduced from 16.75mPa·s to 1.97mPa·s After the oxidation treatment, adjusting pH to 7.5, and treating it with inorganic flocculant and organic flocculant, the water quality met the reinjection requirement of the average air permeability of less than or equal to 0.01 μm2.

  18. Experimental and Numerical Investigations on Colloid-facilitated Plutonium Reactive Transport in Fractured Tuffaceous Rocks

    NASA Astrophysics Data System (ADS)

    Dai, Z.; Wolfsberg, A. V.; Zhu, L.; Reimus, P. W.

    2017-12-01

    Colloids have the potential to enhance mobility of strongly sorbing radionuclide contaminants in fractured rocks at underground nuclear test sites. This study presents an experimental and numerical investigation of colloid-facilitated plutonium reactive transport in fractured porous media for identifying plutonium sorption/filtration processes. The transport parameters for dispersion, diffusion, sorption, and filtration are estimated with inverse modeling for minimizing the least squares objective function of multicomponent concentration data from multiple transport experiments with the Shuffled Complex Evolution Metropolis (SCEM). Capitalizing on an unplanned experimental artifact that led to colloid formation and migration, we adopt a stepwise strategy to first interpret the data from each experiment separately and then to incorporate multiple experiments simultaneously to identify a suite of plutonium-colloid transport processes. Nonequilibrium or kinetic attachment and detachment of plutonium-colloid in fractures was clearly demonstrated and captured in the inverted modeling parameters along with estimates of the source plutonium fraction that formed plutonium-colloids. The results from this study provide valuable insights for understanding the transport mechanisms and environmental impacts of plutonium in fractured formations and groundwater aquifers.

  19. A Case of Acromioclavicular Joint Dislocation Associated with Coracoid Process Fracture.

    PubMed

    Nakamura, Yosuke; Gotoh, Masafumi; Mitsui, Yasuhiro; Shirachi, Isao; Yoshikawa, Eiichiro; Uryu, Takuya; Murakami, Hidetaka; Okawa, Takahiro; Higuchi, Fujio; Shiba, Naoto

    2015-01-01

    Rupture of any two or more parts of the superior shoulder suspensory complex (SSSC) including the distal clavicle, acromion, coracoid process, glenoid cavity of the scapula, acromioclavicular ligament, and coracoclavicular ligament is associated with shoulder girdle instability and is an indication for surgery. Here we report a case of acromioclavicular joint dislocation associated with coracoid process fracture. A 48-year-old man sustained a hard blow to the left shoulder from a fall, and simple radiography detected a coracoid process fracture and acromioclavicular joint dislocation. The injury consisted of a rupture of two parts of the SSSC. For the coracoid process fracture, osteosynthesis was performed using hollow cancellous bone screws. For the acromioclavicular joint dislocation, hook plate fixation and the modified Neviaser's procedure were performed. The bone healed well 5 months after surgery, at which time the screws were removed. At 18 months after initial surgery, the coracoid process fracture had healed with a 10% rate of dislocation on radiography, and the patient currently has no problem performing daily activities, no range of motion limitations, and a Japanese Orthopaedic Association scale score of 93.

  20. Falls: Epidemiology, Pathophysiology, and Relationship to Fracture

    PubMed Central

    Berry, Sarah D.; Miller, Ram

    2009-01-01

    Falls are common in the elderly, and frequently result in injury, disability, and institutionalization. Although the causes of falls are complex, most falls result from an interaction between individual characteristics that increase an individual's propensity to fall and acute mediating risk factors that provide the opportunity to fall. Predisposing risk factors include age-associated changes in strength and balance, age-associated comorbidities such as osteoarthritis, visual impairment and dementia, psychotropic medications, and certain footwear. Fewer studies have focused on acute precipitating factors, but environmental and situational factors are clearly important to the risk of falls. Approximately 30% of falls result in an injury that requires medical attention and with fractures occurring in approximately 10% of falls. Fractures associated with falls are multi-factorial in origin. In addition to the traditional risk factors for falls, the fall descent, fall impact, and bone strength are all important determinants of whether a fracture will occur as a result of an event. In recent years, numerous studies have been directed toward the development of effective fall and fall-related fracture prevention interventions. PMID:19032925

  1. Fractography of poly(methyl methacrylates).

    PubMed

    Kusy, R P; Turner, D T

    1975-07-01

    For convenience in clinical manipulation, it is the practice to fabricate PMMA protheses from mixtures of powder and monomer. When the monomer is subsequently polymerized an unusual 2-phase polymeric material results in which grains of PMMA are dispersed in a matrix of the same polymer. The mechanical properties of the 2-phase materials are inferior in certain respects relative to 1-phase polymers. The purpose of the present work is to evaluate the failure of 2-phase materials by microscopical examination of their fracture surfaces. A granular microstructure was clearly distinguishable and a distinction made between materials which fail exclusively by transgranular fracture and others which additionally exhibit intergranular fracture. In order to interpret markings observed on the fracture surfaces of the complex 2-phase systems a study was made of the influence of molecular weight on the fractography of 1-phase PMMA. Molecular weight was reduced by degradation of samples by exposure to gamma-rays. The spacing of periodic rib markings on fracture surfaces was found to decrease with molecular weight and this relationship used to provide an estimate of the molecular weight of polymer in the matrix of 2-phase materials.

  2. Trauma of the midface

    PubMed Central

    Kühnel, Thomas S.; Reichert, Torsten E.

    2015-01-01

    Fractures of the midface pose a serious medical problem as for their complexity, frequency and their socio-economic impact. Interdisciplinary approaches and up-to-date diagnostic and surgical techniques provide favorable results in the majority of cases though. Traffic accidents are the leading cause and male adults in their thirties are affected most often. Treatment algorithms for nasal bone fractures, maxillary and zygomatic fractures are widely agreed upon whereas trauma to the frontal sinus and the orbital apex are matter of current debate. Advances in endoscopic surgery and limitations of evidence based gain of knowledge are matters that are focused on in the corresponding chapter. As for the fractures of the frontal sinus a strong tendency towards minimized approaches can be seen. Obliteration and cranialization seem to decrease in numbers. Some critical remarks in terms of high dose methylprednisolone therapy for traumatic optic nerve injury seem to be appropriate. Intraoperative cone beam radiographs and preshaped titanium mesh implants for orbital reconstruction are new techniques and essential aspects in midface traumatology. Fractures of the anterior skull base with cerebrospinal fluid leaks show very promising results in endonasal endoscopic repair. PMID:26770280

  3. Fundamental considerations in dynamic fracture in nuclear materials

    NASA Astrophysics Data System (ADS)

    Cady, Carl; Eastwood, David; Bourne, Neil; Pei, Ruizhi; Mummery, Paul; Rau, Christoph

    2017-06-01

    The structural integrity of components used in nuclear power plants is the biggest concern of operators. A diverse range of materials, loading, prior histories and environmental conditions, leads to a complex operating environment. An experimental technique has been developed to characterize brittle materials and using linear elastic fracture mechanics, has given accurate measurements of the fracture toughness of materials. X-ray measurements were used to track the crack front as a function of loading parameters as well as determine the crack surface area as loads increased. This X-ray tomographic study of dynamic fracture in beryllium indicates the onset of damage within the target as load is increased. Similarly, measurements on nuclear graphite were conducted to evaluate the technique. This new, quantitative information obtained using the X-ray techniques has shown application in other materials. These materials exhibited a range of brittle and ductile responses that will test our modelling schemes for fracture. Further visualization of crack front advance and the correlated strain fields that are generated during the experiment for the two distinct deformation processes provide a vital step in validating new multiscale predicative modelling.

  4. Numerical modeling of flow and transport in the far-field of a generic nuclear waste repository in fractured crystalline rock using updated fracture continuum model

    NASA Astrophysics Data System (ADS)

    Hadgu, T.; Kalinina, E.; Klise, K. A.; Wang, Y.

    2016-12-01

    Disposal of high-level radioactive waste in a deep geological repository in crystalline host rock is one of the potential options for long term isolation. Characterization of the natural barrier system is an important component of the disposal option. In this study we present numerical modeling of flow and transport in fractured crystalline rock using an updated fracture continuum model (FCM). The FCM is a stochastic method that maps the permeability of discrete fractures onto a regular grid. The original method by McKenna and Reeves (2005) has been updated to provide capabilities that enhance representation of fractured rock. As reported in Hadgu et al. (2015) the method was first modified to include fully three-dimensional representations of anisotropic permeability, multiple independent fracture sets, and arbitrary fracture dips and orientations, and spatial correlation. More recently the FCM has been extended to include three different methods. (1) The Sequential Gaussian Simulation (SGSIM) method uses spatial correlation to generate fractures and define their properties for FCM (2) The ELLIPSIM method randomly generates a specified number of ellipses with properties defined by probability distributions. Each ellipse represents a single fracture. (3) Direct conversion of discrete fracture network (DFN) output. Test simulations were conducted to simulate flow and transport using ELLIPSIM and direct conversion of DFN methods. The simulations used a 1 km x 1km x 1km model domain and a structured with grid block of size of 10 m x 10m x 10m, resulting in a total of 106 grid blocks. Distributions of fracture parameters were used to generate a selected number of realizations. For each realization, the different methods were applied to generate representative permeability fields. The PFLOTRAN (Hammond et al., 2014) code was used to simulate flow and transport in the domain. Simulation results and analysis are presented. The results indicate that the FCM approach is a viable method to model fractured crystalline rocks. The FCM is a computationally efficient way to generate realistic representation of complex fracture systems. This approach is of interest for nuclear waste disposal models applied over large domains. SAND2016-7509 A

  5. Analysis of a mesoscale infiltration and water seepage test in unsaturated fractured rock: Spatial variabilities and discrete fracture patterns

    USGS Publications Warehouse

    Zhou, Q.; Salve, R.; Liu, H.-H.; Wang, J.S.Y.; Hudson, D.

    2006-01-01

    A mesoscale (21??m in flow distance) infiltration and seepage test was recently conducted in a deep, unsaturated fractured rock system at the crossover point of two underground tunnels. Water was released from a 3??m ?? 4??m infiltration plot on the floor of an alcove in the upper tunnel, and seepage was collected from the ceiling of a niche in the lower tunnel. Significant temporal and (particularly) spatial variabilities were observed in both measured infiltration and seepage rates. To analyze the test results, a three-dimensional unsaturated flow model was used. A column-based scheme was developed to capture heterogeneous hydraulic properties reflected by these spatial variabilities observed. Fracture permeability and van Genuchten ?? parameter [van Genuchten, M.T., 1980. A closed-form equation for predicting the hydraulic conductivity of unsaturated soils. Soil Sci. Soc. Am. J. 44, 892-898] were calibrated for each rock column in the upper and lower hydrogeologic units in the test bed. The calibrated fracture properties for the infiltration and seepage zone enabled a good match between simulated and measured (spatially varying) seepage rates. The numerical model was also able to capture the general trend of the highly transient seepage processes through a discrete fracture network. The calibrated properties and measured infiltration/seepage rates were further compared with mapped discrete fracture patterns at the top and bottom boundaries. The measured infiltration rates and calibrated fracture permeability of the upper unit were found to be partially controlled by the fracture patterns on the infiltration plot (as indicated by their positive correlations with fracture density). However, no correlation could be established between measured seepage rates and density of fractures mapped on the niche ceiling. This lack of correlation indicates the complexity of (preferential) unsaturated flow within the discrete fracture network. This also indicates that continuum-based modeling of unsaturated flow in fractured rock at mesoscale or a larger scale is not necessarily conditional explicitly on discrete fracture patterns. ?? 2006 Elsevier B.V. All rights reserved.

  6. Upscaling Multiphase Fluid Flow in Naturally Fractured Reservoirs

    NASA Astrophysics Data System (ADS)

    Matthai, S.; Maghami-Nick, H.; Belayneh, M.; Geiger, S.

    2009-04-01

    Hydrocarbon recovery from fractured porous reservoirs is difficult to predict as it depends on the focusing of the flow and the local balance of viscous, gravitational, and capillary forces. Hecto-metre scale sub-volumes of fractured oil reservoirs contain thousands of fractures with highly variable flow properties, dimensions and orientations. This complexity precludes direct geometric incorporation into field scale multiphase flow models. Macroscopic laws of their integral effects on multiphase flow are required. These can be investigated by DFM (discrete fracture and matrix) numerical simulations based on discrete fracture models representing fractured reservoir analogues. Here we present DFM results indicating that hecto-metre-scale relative permeability, the time to water breakthrough, and the subsequent water cut primarily depend on the fracture-to-rock matrix flux ratio, qf/qm, quantifying the proportion of the cross-sectional flux that occurs through the fractures. Relative permeability during imbibition runs is best approximated by a rate-dependent new model taking into account capillary fracture-matrix transfer. The up-scaled fractional flow function fo(sw) derived from this new kri formulation is convex with a near-infinity slope at the residual water saturation. This implies that the hector-metre scale spatially averaged Buckley-Leverett equation for fractured porous media does not contain a shock, but a long leading edge in the averaged profile of the invading phase. This dispersive behaviour marks the progressively widening saturation front and an early water breakthrough observed in the discrete fracture reservoir analogues. Since fracture porosity φf is usually only a fraction of a percent, a cross-over from krw < kro to krw/kro ≈ qf/qm occurs after the first few percent of recovery, and because qf/qm ranges between 10-1,000, sweep efficiency ignoring the positive influence of counter-current imbibition is extremely low. The accuracy of reservoir performance predictions by the proposed fo(sw) up-scaling methodology depends on how well φf , qf/qm and a new parameter termed fraction of fracture matrix interface area in contact with the invading fluid, XA,if(si) can be constrained under in situ conditions.

  7. The estimation of CO2 storage potential of gas-bearing shale complex at the early stage of reservoir characterization: the case of Baltic Basin (Poland).

    NASA Astrophysics Data System (ADS)

    Wójcicki, Adam; Jarosiński, Marek

    2017-04-01

    For the stage of shale gas production, like in the USA, prediction of the CO2 storage potential in shale reservoir can be performed by dynamic modeling. We have made an attempt to estimate this potential at an early stage of shale gas exploration in the Lower Paleozoic Baltic Basin, based on data from 3,800 m deep vertical well (without hydraulic fracking stimulation), supplemented with additional information from neighboring boreholes. Such an attempt makes a sense as a first guess forecast for company that explores a new basin. In our approach, the storage capacity is build by: (1) sorption potential of organic matter, (2) open pore space and (3) potential fracture space. the sequence. our estimation is done for 120 m long shale sequence including three shale intervals enriched with organic mater. Such an interval is possible to be fracked from a single horizontal borehole as known from hydraulic fracture treatment in the other boreholes in this region. The potential for adsorbed CO2 is determined from Langmuir isotherm parameters taken from laboratory measurements in case of both CH4 and CO2 adsorption, as well as shale density and volume. CO2 has approximately three times higher sorption capacity than methane to the organic matter contained in the Baltic Basin shales. Finally, due to low permeability of shale we adopt the common assumption for the USA shale basins that the CO2 will be able to reach effectively only 10% of theoretical total sorption volume. The pore space capacity was estimated by utilizing results of laboratory measurements of dynamic capacity for pores bigger than 10 nm. It is assumed for smaller pores adsorption prevails over free gas. Similarly to solution for sorption, we have assumed that only 10 % of the tight pore space will be reached by CO2. For fracture space we have considered separately natural (tectonic-origin) and technological (potentially produced by hydraulic fracturing treatment) fractures. From fracture density profile and typical permeability of fractures under lithostatic stress we inferred negligible open space of natural fractures. Technological fracture space was calculated as an potential for hydraulic stimulation of vertical fractures until, due to elastic expansion of reservoir, the horizontal minimum stress equals the vertical one. In such a case, horizontal fractures start to open and the stimulation process gets to fail. Based on elastic anisotropy and tectonic stress differentiation, the maximum hydraulic horizontal extension was calculated for separated shale complexes. For further storage capacity we assumed that technological fracture space create primary pathway for CO2 transport is entirely accessible for the CO2. In general, the CO2 sorption capacity makes the predominant contribution and fracture space capacity is comparable or smaller than pore space contribution. When compare this with the best recognized Marcellus shale basin we can see that our calculations for the 35 m depth interval comprising formations with the higher TOC content show a slightly lower value than in the case of Marcellus.

  8. Free-Surface flow dynamics and its effect on travel time distribution in unsaturated fractured zones - findings from analogue percolation experiments

    NASA Astrophysics Data System (ADS)

    Noffz, Torsten; Kordilla, Jannes; Dentz, Marco; Sauter, Martin

    2017-04-01

    Flow in unsaturated fracture networks constitutes a high potential for rapid mass transport and can therefore possibly contributes to the vulnerability of aquifer systems. Numerical models are generally used to predict flow and transport and have to reproduce various complex effects of gravity-driven flow dynamics. However, many classical volume-effective modelling approaches often do not grasp the non-linear free surface flow dynamics and partitioning behaviour at fracture intersections in unsaturated fracture networks. Better process understanding can be obtained by laboratory experiments, that isolate single aspects of the mass partitioning process, which influence travel time distributions and allow possible cross-scale applications. We present a series of percolation experiments investigating partitioning dynamics of unsaturated multiphase flow at an individual horizontal fracture intersection. A high precision multichannel dispenser is used to establish gravity-driven free surface flow on a smooth and vertical PMMA (poly(methyl methacrylate)) surface at rates ranging from 1.5 to 4.5 mL/min to obtain various flow modes (droplets; rivulets). Cubes with dimensions 20 x 20 x 20 cm are used to create a set of simple geometries. A digital balance provides continuous real-time cumulative mass bypassing the network. The influence of variable flow rate, atmospheric pressure and temperature on the stability of flow modes is shown in single-inlet experiments. Droplet and rivulet flow are delineated and a transition zone exhibiting mixed flow modes can be determined. Furthermore, multi-inlet setups with constant total inflow rates are used to reduce variance and the effect of erratic free-surface flow dynamics. Investigated parameters include: variable aperture widths df, horizontal offsets dv of the vertical fracture surface and alternating injection methods for both droplet and rivulet flow. Repetitive structures with several horizontal fractures extend arrival times but also complexity and variance. Finally, impacts of variable geometric features and flow modes on partitioning dynamics are highlighted by normalized fracture inflow rates. For higher flow rates, i.e. rivulet flows dominates, the effectiveness of filling horizontal fractures strongly increases. We demonstrate that the filling can be described by plug flow, which transitions into a Washburn-type flow at later times, and derive an analytical solution for the case of rivulet flows. Droplet flow dominated flow experiments exhibit a high bypass efficiency, which cannot be described by plug-flow, however, they also transition into a Washburn stage.

  9. The Ghost in the Machine: Fracking in the Earth's Complex Brittle Crust

    NASA Astrophysics Data System (ADS)

    Malin, P. E.

    2015-12-01

    This paper discusses in the impact of complex rock properties on practical applications like fracking and its associated seismic emissions. A variety of borehole measurements show that the complex physical properties of the upper crust cannot be characterized by averages on any scale. Instead they appear to follow 3 empirical rule: a power law distribution in physical scales, a lognormal distribution in populations, and a direct relation between changes in porosity and log(permeability). These rules can be directly related to the presence of fluid rich and seismically active fractures - from mineral grains to fault segments. (These are the "ghosts" referred to in the title.) In other physical systems, such behaviors arise on the boundaries of phase changes, and are studied as "critical state physics". In analogy to the 4 phases of water, crustal rocks progress upward from a un-fractured, ductile lower crust to nearly cohesionless surface alluvium. The crust in between is in an unstable transition. It is in this layer methods such as hydrofracking operate - be they in Oil and Gas, geothermal, or mining. As a result, nothing is predictable in these systems. Crustal models have conventionally been constructed assuming that in situ permeability and related properties are normally distributed. This approach is consistent with the use of short scale-length cores and logs to estimate properties. However, reservoir-scale flow data show that they are better fit to lognormal distributions. Such "long tail" distributions are observed for well productivity, ore vein grades, and induced seismic signals. Outcrop and well-log data show that many rock properties also show a power-law-type variation in scale lengths. In terms of Fourier power spectra, if peaks per km is k, then their power is proportional to 1/k. The source of this variation is related to pore-space connectivity, beginning with grain-fractures. We then show that a passive seismic method, Tomographic Fracture ImagingTM (TFI), can observe the distribution of this connectivity. Combined with TFI data, our fracture-connectivity model reveals the most significant crustal features and account for their range of passive and stimulated behaviors.

  10. Image processing for quantifying fracture orientation and length scale transitions during brittle deformation

    NASA Astrophysics Data System (ADS)

    Rizzo, R. E.; Healy, D.; Farrell, N. J.

    2017-12-01

    We have implemented a novel image processing tool, namely two-dimensional (2D) Morlet wavelet analysis, capable of detecting changes occurring in fracture patterns at different scales of observation, and able of recognising the dominant fracture orientations and the spatial configurations for progressively larger (or smaller) scale of analysis. Because of its inherited anisotropy, the Morlet wavelet is proved to be an excellent choice for detecting directional linear features, i.e. regions where the amplitude of the signal is regular along one direction and has sharp variation along the perpendicular direction. Performances of the Morlet wavelet are tested against the 'classic' Mexican hat wavelet, deploying a complex synthetic fracture network. When applied to a natural fracture network, formed triaxially (σ1>σ2=σ3) deforming a core sample of the Hopeman sandstone, the combination of 2D Morlet wavelet and wavelet coefficient maps allows for the detection of characteristic scale orientation and length transitions, associated with the shifts from distributed damage to the growth of localised macroscopic shear fracture. A complementary outcome arises from the wavelet coefficient maps produced by increasing the wavelet scale parameter. These maps can be used to chart the variations in the spatial distribution of the analysed entities, meaning that it is possible to retrieve information on the density of fracture patterns at specific length scales during deformation.

  11. Principles of Surgical Treatment in the Midface Trauma - Theory and Practice

    PubMed Central

    VRINCEANU, Daniela; BANICA, Bogdan

    2014-01-01

    Introduction: Facial trauma is a common injury in the urban setting. Many studies have been published on the epidemiology and treatment of facial fractures, but few of them conducted in emergencies hospital as ours. The purpose of this study was to present theory and practice in surgical treatment of midface trauma. Materials and method: We will present a retrospective study and a cases series report with our personal experience in diagnosis and treatment of middle floor facial trauma. Craniofacial trauma in context of polytrauma involves a screening condition assessment of the patient to prioritize lesions and frequently require a multidisciplinary approach: neurosurgeon, ENT surgeon, maxillo-facial surgeon, ophthalmologist, plastic surgeon and so on. Axial and coronal CT are mandatory and three-dimensional CT reconstruction can be extremely useful. Surgical indication in middle floor facial trauma is given by functional and aesthetic deficits. Results: We will present the surgical principles we use in treatment of fractured nose, in fractures of maxilla, in fractures of the zygomatic arch with or without zygoma body fractures and fractures of the floor of orbit. Discussions: The surgical technique was imposed by coexisting lesions of neuro and viscerocranium, by the complexity of the fracture, by functional or aesthetic deficits and by our surgical experience. Conclusions: The main principles in middle face trauma are an accurate and complete lesions evaluation; mixed surgery team with maxillofacial surgeon and neurosurgeon. PMID:25705306

  12. Locking Compression Plate in Distal Femoral Intra-Articular Fractures: Our Experience

    PubMed Central

    Kiran Kumar, G. N.; Sharma, Gaurav; Farooque, Kamran; Sharma, Vijay; Ratan, Ratnav; Yadav, Sanjay; Lakhotia, Devendra

    2014-01-01

    Background. Intra-articular fractures of distal femur present a huge surgical challenge. The aim of this study is to evaluate functional outcome, fracture healing, and the complications of distal femoral intra-articular fractures using locking compression plates. Material and Methods. We reviewed 46 distal femoral fractures treated with distal femoral locking compression plates between 2009 to 2012. There were 36 men and 10 women with mean age of 35 years (range 20–72). More than half of the patients were of type C3 (AO classification) and had been caused by high energy trauma with associated injuries. Results. 2 patients were lost to follow-up. Of the remaining 44 patients, the mean follow-up period was 25 months (range 18–36). The mean time for radiological union was 12 weeks (range 10–18) except 2 patients which had gone for nonunion. At the latest follow up ROM >120° is noted in 32 patients, 90–120 in 10 patients, and 70–90 in 2 patients. 38 patients (86%) had good/excellent outcome. Conclusion. Use of standard lateral approach for simple intra-articular distal femoral fractures (C1) and transarticular/minimally invasive techniques for complex intra-articular fractures (C2/C3) results in improved exposure of the knee joint and better union rates with low incidence of bone grafting. PMID:27355064

  13. A Comparison of Frailty Indexes for the Prediction of Falls, Disability, Fractures and Mortality in Older Men

    PubMed Central

    Ensrud, Kristine E.; Ewing, Susan K.; Cawthon, Peggy M.; Fink, Howard A.; Taylor, Brent C.; Cauley, Jane A.; Dam, Thuy-Tien; Marshall, Lynn M.; Orwoll, Eric S.; Cummings, Steven R.

    2010-01-01

    Objective To compare validity of a parsimonious frailty index (components: weight loss, inability to rise from a chair, and poor energy [SOF index]) with that of the more complex CHS index (components: unintentional weight loss, low grip strength, poor energy, slowness, and low physical activity) for prediction of adverse outcomes in older men. Design Prospective cohort study Setting Six U.S. centers Participants 3132 men ≥67 years Measurements Men classified as robust, intermediate stage or frail using SOF index and criteria similar to those used in CHS index. Falls reported tri-annually for 1 year. Disability (≥1 new impairment in performing IADL) ascertained at 1 year. Fractures and deaths ascertained during 3 years of follow-up. Area under the curve (AUC) statistics from receiver operating characteristic curve analysis compared for models containing SOF index versus CHS index. Results Greater evidence of frailty as defined by either index was associated with increased risks of adverse outcomes. Frail men had a higher age-adjusted risk of recurrent falls (odds ratio [OR] 3.0–3.6), disability (OR 5.3–7.5), nonspine fracture (hazards ratio [HR] 2.2–2.3), and death (HR 2.5–3.5) (P<0.001 for all models). AUC comparisons revealed no differences between models with SOF index versus models with CHS index in discriminating falls (AUC=0.63, P= 0.97), disability (AUC=0.68, P=0.86), nonspine fracture (AUC=0.63, P=0.90), or death (AUC=0.71 for model with SOF index and 0.72 for model with CHS index, P=0.19). Conclusion The simple SOF index predicts risk of falls, disability, fracture and mortality in men as well as the more complex CHS index. PMID:19245414

  14. A microfluidic investigation of gas exsolution in glass and shale fracture networks

    NASA Astrophysics Data System (ADS)

    Porter, M. L.; Jimenez-Martinez, J.; Harrison, A.; Currier, R.; Viswanathan, H. S.

    2016-12-01

    Microfluidic investigations of pore-scale fluid flow and transport phenomena has steadily increased in recent years. In these investigations fluid flow is restricted to two-dimensions allowing for real-time visualization and quantification of complex flow and reactive transport behavior, which is difficult to obtain in other experimental systems. In this work, we describe a unique high pressure (up to 10.3 MPa) and temperature (up to 80 °C) microfluidics experimental system that allows us to investigate fluid flow and transport in geo-material (e.g., shale, Portland cement, etc.) micromodels. The use of geo-material micromodels allows us to better represent fluid-rock interactions including wettability, chemical reactivity, and nano-scale porosity at conditions representative of natural subsurface environments. Here, we present experimental results in fracture systems with applications to hydrocarbon mobility in fractured rocks. Complex fracture network patterns are derived from 3D x-ray tomography images of actual fractures created in shale rock cores. We use both shale and glass micromodels, allowing for a detailed comparison between flow phenomena in the different materials. We discuss results from two-phase gas (CO2 and N2) injection experiments designed to enhance oil recovery. In these experiments gas was injected into micromodels saturated with oil and allowed to soak for approximately 12 hours at elevated pressures. The pressure in the system was then decreased to atmospheric, causing the gas to expand and/or dissolve out of solution, subsequently mobilizing the oil. In addition to the experimental results, we present a relatively simple model designed to quantify the amount of oil mobilized as a function of decreasing system pressure. We will show comparisons between the experiments and model, and discuss the potential use of the model in field-scale reservoir simulations.

  15. Pyrite–sulfosalt reactions and semimetal fractionation in the Chinkuashih, Taiwan, copper–gold deposit: a 1 Ma paleo-fumarole

    USGS Publications Warehouse

    Henley, R.W.; Berger, Byron R.

    2012-01-01

    The mineralized fracture system that underlay paleo-fumarole field at Chinkuashih, Taiwan has been exposed by copper–gold mining to depths of about 550 m below the paleo-surface. Its mineralogy and systematic variations in metal and semimetal (Fe, Cu, As, Sb, Bi, Hg, Cd, Sn, Zn, Pb, Se, Te, Au, Ag) concentrations provide insights into the chemical responses of a magmatic-vapor phase as it expands through fracture arrays to the surface and discharges as fumaroles associated with more extensive solfatara. At Chinkuashih, following initial sealing of the fractures by silica-alunite alteration, brittle failure reestablished discharge from an underlying reservoir of magmatic vapor. Crystalline pyrite was deposited first in the fractures and was succeeded and replaced by ‘enargite’ (Cu3(As,Sb)S4) as sulfosalt encrustations (‘sublimate’) on fracture surfaces and in extensional cracks. Subsequent recrystallization resulted in complex exsolution intergrowths with antimony fractionation to the evolving crystal–vapor interface. Heavy metal fractionation between sulfosalt and vapor enriched the vapor phase in heavy metals that subsequently precipitated as complex Bi–Hg–Sn sulfosalts in discrete areas (paleo-fumaroles) close to the paleo-surface in a manner analogous to modern-day fumaroles on active volcanoes such as Vulcano, Italy. As in similar paleo-fumaroles (e.g., El Indio, Chile and Lepanto, Philippines), the most characteristic reaction sequence is the partial replacement of the early pyrite by enargite and Fe-tennantite. It is proposed that this reaction tracks the decrease in the pressure of the underlying magmatic-vapor reservoir because of the sustained discharge of vapor to the surface.

  16. Modelling of Tc migration in an un-oxidized fractured drill core from Äspö, Sweden

    NASA Astrophysics Data System (ADS)

    Huber, F. M.; Totskiy, Y.; Montoya Garcia, V.; Enzmann, F.; Trumm, M.; Wenka, A.; Geckeis, H.; Schaefer, T.

    2015-12-01

    The radionuclide retention of redox sensitive radionuclides (e.g. Pu, Np, U, Tc) in crystalline host rock greatly depends on the rock matrix and the rock redox capacity. Preservation of drill cores concerning oxidation is therefore of paramount importance to reliably predict the near-natural radionuclide retention properties. Here, experimental results of HTO and Tc laboratory migration experiments in a naturally single fractured Äspö un-oxidized drill core are modelled using two different 2D models. Both models employ geometrical information obtained by μ-computed tomography (μCT) scanning of the drill core. The models differ in geometrical complexity meaning the first model (PPM-MD) consists of a simple parallel plate with a porous matrix adjacent to the fracture whereas the second model (MPM) uses the mid-plane of the 3D fracture only (no porous matrix). Simulation results show that for higher flow rates (Peclet number > 1), the MPM satisfactorily describes the HTO breakthrough curves (BTC) whereas the PPM-MD model nicely reproduces the HTO BTC for small Pe numbers (<1). These findings clearly highlight the influence of fracture geometry/flow field complexity on solute transport for Pe numbers > 1 and the dominating effect of matrix diffusion for Peclet numbers < 1. Retention of Tc is modelled using a simple Kd-approach in case of the PPM-MD and including 1st order sorptive reduction/desorption kinetics in case of the MPM. Batch determined sorptive reduction/desorption kinetic rates and Kd values for Tc on non-oxidized Äspö diorite are used in the model and compared to best fit values. By this approach, the transferability of kinetic data concerning sorptive reduction determined in static batch experiments to dynamic transport experiments is examined.

  17. Applications of Automation Methods for Nonlinear Fracture Test Analysis

    NASA Technical Reports Server (NTRS)

    Allen, Phillip A.; Wells, Douglas N.

    2013-01-01

    Using automated and standardized computer tools to calculate the pertinent test result values has several advantages such as: 1. allowing high-fidelity solutions to complex nonlinear phenomena that would be impractical to express in written equation form, 2. eliminating errors associated with the interpretation and programing of analysis procedures from the text of test standards, 3. lessening the need for expertise in the areas of solid mechanics, fracture mechanics, numerical methods, and/or finite element modeling, to achieve sound results, 4. and providing one computer tool and/or one set of solutions for all users for a more "standardized" answer. In summary, this approach allows a non-expert with rudimentary training to get the best practical solution based on the latest understanding with minimum difficulty.Other existing ASTM standards that cover complicated phenomena use standard computer programs: 1. ASTM C1340/C1340M-10- Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program 2. ASTM F 2815 - Standard Practice for Chemical Permeation through Protective Clothing Materials: Testing Data Analysis by Use of a Computer Program 3. ASTM E2807 - Standard Specification for 3D Imaging Data Exchange, Version 1.0 The verification, validation, and round-robin processes required of a computer tool closely parallel the methods that are used to ensure the solution validity for equations included in test standard. The use of automated analysis tools allows the creation and practical implementation of advanced fracture mechanics test standards that capture the physics of a nonlinear fracture mechanics problem without adding undue burden or expense to the user. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.

  18. Gypsum crystallization from cadmium-poisoned solutions

    NASA Astrophysics Data System (ADS)

    Rinaudo, C.; Franchini-Angela, M.; Boistelle, R.

    1988-06-01

    Gypsum crystals, CaSO4⋯2H2O, are grown from solutions containing large amounts of cadmium chloride as an impurity. The initial supersaturations necessary for the gypsum nucleation increase with increasing cadmium concentration. Accordingly, at constant initial supersaturation, the induction periods also increase with increasing cadmium concentration. Cadmium and chlorine are incorporated into the crystals probably as CdCl+ or CdCl2, which are the most abundant complexes in the solutions. Consequently, the gypsum crystals grow curved, distorted and exhibit fractures along the [100] direction. The amount of incorporated cadmium increases with increasing supersaturation. Cadmium is mainly detected near the {120} faces in the area where the fractures release the internal stresses. Supersaturation and concentration of free ions and complexes are calculated for all solutions. Adsorption on {120} is discussed.

  19. Management of post-traumatic elbow instability after failed radial head excision: A case report.

    PubMed

    Touloupakis, Georgios; Theodorakis, Emmanouil; Favetti, Fabio; Nannerini, Massimiliano

    2017-02-01

    Radial head excision has always been a safe commonly used surgical procedure with a satisfactory clinical outcome for isolated comminuted radial head fractures. However, diagnosis of elbow instability is still very challenging and often underestimated in routine orthopaedic evaluation. We present the case of a 21-years old female treated with excision after radial head fracture, resulting in elbow instability. The patient underwent revision surgery after four weeks. We believe that ligament reconstruction without radial head substitution is a safe alternative choice for Mason III radial head fractures accompanied by complex ligament lesions. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  20. Sandia fracture challenge 2: Sandia California's modeling approach

    DOE PAGES

    Karlson, Kyle N.; James W. Foulk, III; Brown, Arthur A.; ...

    2016-03-09

    The second Sandia Fracture Challenge illustrates that predicting the ductile fracture of Ti-6Al-4V subjected to moderate and elevated rates of loading requires thermomechanical coupling, elasto-thermo-poro-viscoplastic constitutive models with the physics of anisotropy and regularized numerical methods for crack initiation and propagation. We detail our initial approach with an emphasis on iterative calibration and systematically increasing complexity to accommodate anisotropy in the context of an isotropic material model. Blind predictions illustrate strengths and weaknesses of our initial approach. We then revisit our findings to illustrate the importance of including anisotropy in the failure process. Furthermore, mesh-independent solutions of continuum damage modelsmore » having both isotropic and anisotropic yields surfaces are obtained through nonlocality and localization elements.« less

Top