Sample records for complexometric titration note

  1. Graphical evaluation of complexometric titration curves.

    PubMed

    Guinon, J L

    1985-04-01

    A graphical method, based on logarithmic concentration diagrams, for construction, without any calculations, of complexometric titration curves is examined. The titration curves obtained for different kinds of unidentate, bidentate and quadridentate ligands clearly show why only chelating ligands are usually used in titrimetric analysis. The method has also been applied to two practical cases where unidentate ligands are used: (a) the complexometric determination of mercury(II) with halides and (b) the determination of cyanide with silver, which involves both a complexation and a precipitation system; for this purpose construction of the diagrams for the HgCl(2)/HgCl(+)/Hg(2+) and Ag(CN)(2)(-)/AgCN/CN(-) systems is considered in detail.

  2. Visualization of Metal Ion Buffering via Three-Dimensional Topographic Surfaces (Topos) of Complexometric Titrations

    ERIC Educational Resources Information Center

    Smith, Garon C.; Hossain, Md Mainul

    2017-01-01

    "Complexation TOPOS" is a free software package to generate 3-D topographic surfaces ("topos") for metal-ligand complexometric titrations in aqueous media. It constructs surfaces by plotting computed equilibrium parameters above a composition grid with "volume of ligand added" as the x-axis and overall system dilution…

  3. Standardization and validation of a new atomic absorption spectroscopy technique for determination and quantitation of aluminium adjuvant in immunobiologicals.

    PubMed

    Mishra, Arti; Bhalla, Sumir Rai; Rawat, Sameera; Bansal, Vivek; Sehgal, Rakesh; Kumar, Sunil

    2007-10-01

    In the present study, Aluminium quantification in immunobiologicals has been described using atomic absorption spectroscopy (AAS) technique. The assay was found to be linear in 25-125 microg/ml Aluminium range. The procedure was found to be accurate for different vaccines with recoveries of external additions ranging between 93.26 and 103.41%. The mean Limit of Variation (L.V.) for both intra- and inter-assay precision was calculated to be 1.62 and 2.22%, respectively. Further the procedure was found to be robust in relation to digestion temperature, alteration in acid (HNO(3) and H(2)SO(4)) ratio used for sample digestion and storage of digested vaccine samples up to a period of 15 days. After validation, AAS method was compared for its equivalency with routinely used complexometric titration method. On simultaneously applying on seven different groups of both bacterial and viral vaccines, viz., DPT, DT, TT, Hepatitis-A and B, Antirabies vaccine (cell culture) and tetravalent DPT-Hib, a high degree of positive correlation (+0.85-0.998) among AAS and titration methods was observed. Further AAS method was found to have an edge over complexometric titration method that a group of vaccines, viz., ARV (cell culture, adsorbed) and Hepatitis-A, in which Aluminium estimation is not feasible by pharmacopoeial approved complexometric titration method (possibly due to some interference in the sample matrix), this newly described and validated AAS assay procedure delivered accurate and reproducible results.

  4. Complexometric determination of some toxic mixtures of ions using bromo-cresol orange with visual endpoint indication.

    PubMed

    Hafez, M A; Khalifa, M E

    1997-05-01

    A rapid and simple general complexometric method was presented for the determination of lead, cadmium and thallium or mercury or arsenic(V) in laboratory synthesized mixtures similar to those of some ores, minerals and alloys of such metals. The precision and accuracy attainable in successive titrations of Pb(2+), Cd(2+) and Tl(3+) or Hg(2+) or AsO(3-)(4) (As(5+)) with 0.05 and/or 0.01 mol 1(-1) solutions of disodium ethylenediaminetetraacetate (Na(2)EDTA) and standard Pb(NO(3))(2) of the same concentration using Bromo-Cresol Orange (BCO) as a new metallochromic indicator with visual endpoint indication were studied. For the analysis of a three component mixtures of the aforementioned ions, Tl(3+) was at first directly titrated with Na(2)EDTA at pH 0.5-1 (HNO(3)) using BCO as indicator. At the thallium endpoint an excess of Na(2)EDTA was added and the pH was adjusted at pH approximately 4.8 using hexamine-HNO(3) buffer (solution A). The excess EDTA was back-titrated with standard solution of Pb(NO(3))(2). 1,10-Phenanthroline (1,10-phen) was added to release the EDTA combined with Cd(2+), while thiosemicarbazide (TSC) was used to liberate the EDTA from the mercury-EDTA chelate. To determine AsO(3-)(4) ion in such type of mixtures the pH of (solution A) was raised to a value of 10 using ammonia buffer. Excess standard Mg(2+) solution was added and the formed precipitate of MgNH(4)AsO(4) was separated, dissolved and its magnesium content equivalent to AsO(3-)(4) was determined complexometrically using Eriochrome Black-T (EBT) indicator. The interference caused by different anions, cations and organic acids was investigated. A comparison of the indicators BCO and Xylenol Orange (XO) for successive titration of the studied metal ions was carried out. The proposed successive titration method was applied successfully to some real samples of ores, minerals and alloys of the studied metal ions and the results were satisfactory and agreed with those obtained by AAS.

  5. Signal processing with a summing operational amplifier in multicomponent potentiometric titrations.

    PubMed

    Parczewski, A

    1987-06-01

    It has been proved that application of two indicator electrodes connected to the ordinary titration apparatus through an auxiliary electronic device (a summing operational amplifier) significantly extends the scope of multicomponent potentiometric titrations in which the analytes are determined simultaneously from a single titration curve. For each analyte there is a corresponding potential jump on the titration curve. By application of the proposed auxiliary device, the sum of the electrode potentials is measured. The device also enables the relative sizes of the potential jumps at the end-points on the titration curve to be varied. The advantages of the proposed signal processing are exemplified by complexometric potentiometric titrations of Fe(III) and Cu(II) in mixtures, with a platinum electrode and a copper ion-selective electrode as the indicator electrodes.

  6. Complexometric determination of gallium with calcein blue as indicator

    USGS Publications Warehouse

    Elsheimer, H.N.

    1967-01-01

    A metalfluorechromic indicator, Calcein Blue, has been used for the back-titration of milligram amounts of EDTA in presence of gallium complexes. The indicator was used in conjunction with an ultraviolet titration assembly equipped with a cadmium sulphide detector cell and a microammeter for enhanced end-point detection. The result is a convenient and rapid method with an accuracy approaching 0.1 % and a relative standard deviation of about 0.4% for 10 mg of gallium. ?? 1967.

  7. Polyether precursors of molecular recognition systems based on the 9,10-anthraquinone moiety

    NASA Astrophysics Data System (ADS)

    Wcisło, Anna; Cirocka, Anna; Zarzeczańska, Dorota; Niedziałkowski, Paweł; Nakonieczna, Sandra; Ossowski, Tadeusz

    2015-02-01

    A series of novel polyether derivatives of 9,10-anthraquinone (AQ) was synthesized and characterized by means of UV-Vis spectroscopy, acid-base titration and complexometric titration. The results were compared with 1-NEt2AQ and 1-NHEtAQ - model compounds of alkylaminoanthraquinones. Acetonitrile and methanol were used as solvents for determination of spectroscopic and acid-base properties. Complexometric titrations were carried out exclusively in acetonitrile. Spectral characteristic of these compounds strongly depends on pH. Addition of acid causes the decrease of absorption intensity and in some cases also a shift of the visible range band. The weakest base is the compound (2), and the strongest - compound (1), both in methanol and acetonitrile solution. The introduction of an additional substituent in the position 8 of the anthraquinone compound increases its basicity. The presence of metal ions causes changes in intensity of absorption (decrease for compounds (2) and (3) and increase with bathochromic shift for (1) and (4)). For the determination of the coordination properties aluminum (III) ions were chosen. The highest complex stability constant with Al (III) ions is observed for compound (1), and the weakest for compound (3). The elongation of the polyether chain decreases the stability of the complex formed.

  8. Polyether precursors of molecular recognition systems based on the 9,10-anthraquinone moiety.

    PubMed

    Wcisło, Anna; Cirocka, Anna; Zarzeczańska, Dorota; Niedziałkowski, Paweł; Nakonieczna, Sandra; Ossowski, Tadeusz

    2015-02-25

    A series of novel polyether derivatives of 9,10-anthraquinone (AQ) was synthesized and characterized by means of UV-Vis spectroscopy, acid-base titration and complexometric titration. The results were compared with 1-NEt2AQ and 1-NHEtAQ--model compounds of alkylaminoanthraquinones. Acetonitrile and methanol were used as solvents for determination of spectroscopic and acid-base properties. Complexometric titrations were carried out exclusively in acetonitrile. Spectral characteristic of these compounds strongly depends on pH. Addition of acid causes the decrease of absorption intensity and in some cases also a shift of the visible range band. The weakest base is the compound (2), and the strongest--compound (1), both in methanol and acetonitrile solution. The introduction of an additional substituent in the position 8 of the anthraquinone compound increases its basicity. The presence of metal ions causes changes in intensity of absorption (decrease for compounds (2) and (3) and increase with bathochromic shift for (1) and (4)). For the determination of the coordination properties aluminum (III) ions were chosen. The highest complex stability constant with Al (III) ions is observed for compound (1), and the weakest for compound (3). The elongation of the polyether chain decreases the stability of the complex formed. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Development of a potentiometric EDTA method for determination of molybdenum. Use of the analysis for molybdenite concentrates

    NASA Technical Reports Server (NTRS)

    Khristova, R.; Vanmen, M.

    1986-01-01

    Based on considerations of principles and experimental data, the interference of sulfate ions in poteniometric titration of EDTA with FeCl3 was confirmed. The method of back complexometric titration of molybdenum of Nonova and Gasheva was improved by replacing hydrazine sulfate with hydrazine hydrochloride for reduction of Mo(VI) to Mo(V). The method can be used for one to tenths of mg of molybdenum with 0.04 mg standard deviation. The specific method of determination of molybdenum in molybdenite concentrates is presented.

  10. Stepwise Inquiry into Hard Water in a High School Chemistry Laboratory

    ERIC Educational Resources Information Center

    Kakisako, Mami; Nishikawa, Kazuyuki; Nakano, Masayoshi; Harada, Kana S.; Tatsuoka, Tomoyuki; Koga, Nobuyoshi

    2016-01-01

    This study focuses on the design of a learning program to introduce complexometric titration as a method for determining water hardness in a high school chemistry laboratory. Students are introduced to the different properties and reactions of hard water in a stepwise manner so that they gain the necessary chemical knowledge and conceptual…

  11. Determination of Calcium in Dietary Supplements: Statistical Comparison of Methods in the Analytical Laboratory

    ERIC Educational Resources Information Center

    Garvey, Sarah L.; Shahmohammadi, Golbon; McLain, Derek R.; Dietz, Mark L.

    2015-01-01

    A laboratory experiment is described in which students compare two methods for the determination of the calcium content of commercial dietary supplement tablets. In a two-week sequence, the sample tablets are first analyzed via complexometric titration with ethylenediaminetetraacetic acid and then, following ion exchange of the calcium ion present…

  12. A SIMPLE AND RAPID METHOD FOR THE SIMULTANEOUS DETERMINATION OF CALCIUM AND MAGNESIUM FROM THE SAME SAMPLE OF BLOOD SERUM

    PubMed Central

    Kovács, G. S.; Tárnoky, K. E.

    1960-01-01

    A simple and rapid procedure has been developed for the complexometric titration of serum calcium and magnesium using “plasmocorinth B” as indicator. Both determinations can be carried out from the same 0.5 ml. sample. The method is in good agreement with the established calcium and magnesium methods. PMID:14411396

  13. Safety study of intravitreal and suprachoroidal Laponite clay in rabbit eyes.

    PubMed

    Prieto, Esther; Vispe, Eugenio; De Martino, Alba; Idoipe, Miriam; Rodrigo, María J; Garcia-Martin, Elena; Fraile, José M; Polo-Llorens, Vicente; Mayoral, José A

    2018-03-01

    To study the safety and biocompatibility of Laponite clay (LAP) within an intravitreal and suprachoroidal administration in rabbit eyes. Thirty-two New Zealand albino rabbits were divided into two experimental groups to test intravitreal (IVT group) and suprachoroidal (SCS group) administration of a 100-μl and 50-μl Laponite suspension respectively. Following injection, the eyes were monitored by ocular tonometry, slit-lamp eye examination and indirect ophthalmoscopy, at 24 h, 1, 4, 12, and 14 weeks post administration. Histological examination was also performed to determine whether any ocular pathological change had occurred. Throughout the study, LAP presence in vitreous was estimated by complexometric titration with ethylenediaminetetraacetic acid (EDTA), taking advantage of the Laponite high content of magnesium ions. Neither significant differences in the intraocular pressure, nor relevant ocular complications were found in the two experimental groups after LAP administration. The histology of the retina remained unchanged. LAP presence in vitreous could be indirectly confirmed by complexometric titration until 14 weeks post administration in eyes of IVT group. Laponite could be considered as a vehicle for potential clinical use in ocular drug administration, due to its proven ocular biocompatibility and its transparency in gel state.

  14. Ion-selective electrodes in potentiometric titrations; a new method for processing and evaluating titration data.

    PubMed

    Granholm, Kim; Sokalski, Tomasz; Lewenstam, Andrzej; Ivaska, Ari

    2015-08-12

    A new method to convert the potential of an ion-selective electrode to concentration or activity in potentiometric titration is proposed. The advantage of this method is that the electrode standard potential and the slope of the calibration curve do not have to be known. Instead two activities on the titration curve have to be estimated e.g. the starting activity before the titration begins and the activity at the end of the titration in the presence of large excess of titrant. This new method is beneficial when the analyte is in a complexed matrix or in a harsh environment which affects the properties of the electrode and the traditional calibration procedure with standard solutions cannot be used. The new method was implemented both in a method of linearization based on the Grans's plot and in determination of the stability constant of a complex and the concentration of the complexing ligand in the sample. The new method gave accurate results when using titrations data from experiments with samples of known composition and with real industrial harsh black liquor sample. A complexometric titration model was also developed. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Validated flow-injection method for rapid aluminium determination in anti-perspirants.

    PubMed

    López-Gonzálvez, A; Ruiz, M A; Barbas, C

    2008-09-29

    A flow-injection (FI) method for the rapid determination of aluminium in anti-perspirants has been developed. The method is based on the spectrophotometric detection at 535nm of the complex formed between Al ions and the chromogenic reagent eriochrome cyanine R. Both the batch and FI methods were validated by checking the parameters included in the ISO-3543-1 regulation. Variables involved in the FI method were optimized by using appropriate statistical tools. The method does not exhibit interference from other substances present in anti-perspirants and it shows a high precision with a R.S.D. value (n=6) of 0.9%. Moreover, the accuracy of the method was evaluated by comparison with a back complexometric titration method, which is currently used for routine analysis in pharmaceutical laboratories. The Student's t-test showed that the results obtained by both methods were not significantly different for a significance level of 95%. A response time of 12s and a sample analysis time, by performing triplicate injections, of 60s were achieved. The analytical figures of merit make the method highly appropriate to substitute the time-consuming complexometric method for this kind of analysis.

  16. Determining the EDTA Content in a Consumer Shower Cleaner. An Introductory Chemistry Laboratory Experiment

    NASA Astrophysics Data System (ADS)

    Weigand, Willis A.

    2000-10-01

    At Altoona College, Chemistry 11 is offered to students as a preparatory course for the University's Chemical Principles course, Chem 12. A relevant laboratory is a source of motivation for the students to learn the chemistry. One way of making the laboratory relevant is to analyze the chemical components of consumer products. Several new shower-cleaning products have been introduced, which advertise that cleaning the shower is no longer necessary. The cleaners work using a combination of surfactants, alcohols, and a chelating agent. The Web site of a popular shower cleaner lists EDTA (ethylenediamine tetraacetate ion) as the chelating agent. The classic EDTA/calcium complexometric titration can be used to determine the EDTA content of the cleaner. This article describes the experiment to determine the EDTA content in a shower-cleaning product.

  17. Iron Speciation in the Subtropical Waters East of New Zealand using Multi Detection Window CLE-AdCSV Titrations.

    NASA Astrophysics Data System (ADS)

    Chandrasekhar, Anoop; Sander, Sylvia; Milnes, Angie; Boyd, Philip

    2015-04-01

    Iron plays a significant role in the ocean productivity as a micro nutrient that facilitates the growth of marine phytoplankton and microbes. The bioavailability of iron in the ocean depends on it speciation. Iron is bio available in its dissolved form and about 99.9% of dissolved iron in seawater is organically complexed with natural ligands. The competitive ligand equilibration - adsorptive cathodic stripping voltammetry (CLE-AdCSV) is the widely used technique to examine Fe speciation. The method has its own limitations. The analytical window employed in this technique has a distinct impact on Fe speciation results (Buck, Moffett et al. 2012). Recently, (Pizeta, Sander et al. in preparation) have shown that the accuracy of complexometric titrations improve if multiple analytical windows (MAW) are solved as a united dataset. Several programs are now available that enable this approach with the KMS (Kineteql.xls , Hudson 2014), which is based on an Excel application based on speciation calculation (Hudson, Rue et al. 2003, Sander, Hunter et al. 2011), being one of them. In the present work, the unified MAW data analysis method is applied to determine iron speciation by CLE-AdCSV with salicyl aldoxime (SA) (Abualhaija and van den Berg 2014) in real seawater samples from the Spring bloom FeCycle III voyage, which took place in an anticyclonic eddy in subtropical waters east of New Zealand in spring 2012. Two different analytical windows (5 and 15µM SA) were applied to samples from depth profiles taken during this cruise. The data obtained was analysed using the program KMS (Kineteql.xls). Most samples only returned one Fe-binding ligands class. Higher ligand concentrations were observed in the upper water column and the stability constants were above 22 (e.g. 22.25 ± 0.21 for station 63). Our results will be discussed in the context of microbial community distribution as well as other biogeochemical parameters. Abualhaija, M. M. and C. M. G. van den Berg (2014). "Chemical speciation of iron in seawater using catalytic cathodic stripping voltammetry with ligand competition against salicylaldoxime." Marine Chemistry 164(0): 60-74. Buck, K. N., J. Moffett, K. A. Barbeau, R. M. Bundy, Y. Kondo and J. Wu (2012). "The organic complexation of iron and copper: an intercomparison of competitive ligand exchange-adsorptive cathodic stripping voltammetry (CLE-ACSV) techniques " Limnology and Oceanography: Methods 10: 496-515. Hudson, R. J. M., E. L. Rue and K. W. Bruland (2003). "Modeling Complexometric Titrations of Natural Water Samples." Environ. Sci. Tech. 37: 1553-1562. Pizeta, I., S. G. Sander, O. Baars, K. Buck, R. Bundy, G. Carrasco, P. Croot, C. Garnier, L. Gerringa, M. Gledhill, K. Hirose, D. R. Hudson, Y. Kondo-Jacquot, L. Laglera, D. Omanovic, M. Rijkenberg, B. Twining and M. Wells (in preparation). "Intercomparison of estimating metal binding ligand parameters from simulated titration data using different fitting approaches." for Limnology and Oceanography: Methods. Sander, S. G., K. A. Hunter, H. Harms and M. Wells (2011). "Numerical approach to speciation and estimation of parameters used in modeling trace metal bioavailability." Environmental Science and Technology 45(15): 6388-6395.

  18. Metal Doped Manganese Oxide Thin Films for Supercapacitor Application.

    PubMed

    Tung, Mai Thanh; Thuy, Hoang Thi Bich; Hang, Le Thi Thu

    2015-09-01

    Co and Fe doped manganese oxide thin films were prepared by anodic deposition at current density of 50 mA cm(-2) using the electrolyte containing manganese sulfate and either cobalt sulfate or ferrous sulfate. Surface morphology and crystal structure of oxides were studied by scanning electron microscope (SEM) and X-ray diffraction (XRD). Chemical composition of materials was analyzed by X-ray energy dispersive spectroscope (EDS), iodometric titration method and complexometric titration method, respectively. Supercapacitive behavior of Co and Fe doped manganese oxide films were characterized by cyclic voltammetry (CV) and impedance spectroscopy (EIS). The results show that the doped manganese oxides are composed of nano fiber-like structure with radius of 5-20 nm and remain amorphous structure after heat treatment at 100 degrees C for 2 hours. The average valence of manganese increases from +3.808 to +3.867 after doping Co and from +3.808 to +3.846 after doping Fe. The doped manganese oxide film electrodes exhibited preferably ideal pseudo-capacitive behavior. The specific capacitance value of deposited manganese oxide reaches a maximum of 175.3 F/g for doping Co and 244.6 F/g for doping Fe. The thin films retained about 84% of the initial capacity even after 500 cycles of charge-discharge test. Doping Co and Fe decreases diffusion and charge transfer resistance of the films. The electric double layer capacitance and capacitor response frequency are increased after doping.

  19. Estimation of changes in nickel and chromium content in nickel-titanium and stainless steel orthodontic wires used during orthodontic treatment: An analytical and scanning electron microscopic study.

    PubMed

    Kararia, Vandana; Jain, Pradeep; Chaudhary, Seema; Kararia, Nitin

    2015-01-01

    The biocompatibility of orthodontic dental alloys has been investigated over the past 20 years, but the results have been inconclusive. The study compares standard 3 M Unitek nickel-titanium (NiTi) and stainless steel archwires with locally available JJ orthodontics wires. Scanning electron microscope (SEM) study of surface changes and complexometric titration to study compositional change was performed. Ten archwires each of group 1-3 M 0.016" NiTi, group 2-JJ 0.016" NiTi, group 3-3 M 0.019" *0.025" SS and group 4-JJ SS contributed a 10 mm piece of wire for analysis prior to insertion in the patient and 6 weeks post insertion. SEM images were recorded at ×2000, ×4000 and ×6000 magnification. The same samples were subjected to complexiometric titration using ethylenediaminetetraacetic acid to gauge the actual change in the composition. The SEM images of all the archwires showed marked changes with deep scratches and grooves and dark pitting corrosion areas post intraoral use. 3M wires showed an uniform criss-cross pattern in as received wires indicating a coating which was absent after intraoral use. There was a significant release of Nickel and Chromium from both group 3 and 4. Group 2 wires released ions significantly more than group 1 (P = 0.0). Extensive and stringent trials are required before certifying any product to be used in Orthodontics.

  20. Preparation and characterization of composites based on the blends of collagen, chitosan and hyaluronic acid with nano-hydroxyapatite.

    PubMed

    Sionkowska, Alina; Kaczmarek, Beata

    2017-09-01

    3D porous composites based on the blend of chitosan, collagen and hyaluronic acid with the addition of nano-hydroxyapatite were prepared. SEM images for the composites were made and the structure was assessed. Mechanical properties were studied using a Zwick&Roell Testing Mashine. In addition, the porosity and density of composites were measured. The concentration of calcium ions released from the material was detected by the complexometric titration method. The results showed that in 3D porous sponge based on the blend of chitosan, collagen and hyaluronic acid, inorganic particles of nanohydroxyapatite can be incorporated, as well as that the properties of 3D composites depend on the material composition. Mechanical parameters and thermal stability of ternary biopolymeric blends were improved by the addition of hydroxyapatite. Moreover, the porosity of ternary materials was higher than in materials based on pure chitosan or collagen. All composites were characterized by a porous structure with interconnected pores. Calcium ions can be released from the composite during its degradation in water. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Estimation of changes in nickel and chromium content in nickel-titanium and stainless steel orthodontic wires used during orthodontic treatment: An analytical and scanning electron microscopic study

    PubMed Central

    Kararia, Vandana; Jain, Pradeep; Chaudhary, Seema; Kararia, Nitin

    2015-01-01

    Introduction: The biocompatibility of orthodontic dental alloys has been investigated over the past 20 years, but the results have been inconclusive. The study compares standard 3 M Unitek nickel-titanium (NiTi) and stainless steel archwires with locally available JJ orthodontics wires. Scanning electron microscope (SEM) study of surface changes and complexometric titration to study compositional change was performed. Materials and Methods: Ten archwires each of group 1–3 M 0.016” NiTi, group 2-JJ 0.016” NiTi, group 3–3 M 0.019” *0.025” SS and group 4-JJ SS contributed a 10 mm piece of wire for analysis prior to insertion in the patient and 6 weeks post insertion. SEM images were recorded at ×2000, ×4000 and ×6000 magnification. The same samples were subjected to complexiometric titration using ethylenediaminetetraacetic acid to gauge the actual change in the composition. Observations and Results: The SEM images of all the archwires showed marked changes with deep scratches and grooves and dark pitting corrosion areas post intraoral use. 3M wires showed an uniform criss-cross pattern in as received wires indicating a coating which was absent after intraoral use. There was a significant release of Nickel and Chromium from both group 3 and 4. Group 2 wires released ions significantly more than group 1 (P = 0.0). Conclusion: Extensive and stringent trials are required before certifying any product to be used in Orthodontics. PMID:25684911

  2. The n-propyl 3-azido-2,3-dideoxy-β-D-arabino-hexopyranoside: Syntheses, crystal structure, physical properties and stability constants of their complexes with Cu(II), Ni(II) and VO(II)

    NASA Astrophysics Data System (ADS)

    Barabaś, Anna; Madura, Izabela D.; Marek, Paulina H.; Dąbrowska, Aleksandra M.

    2017-11-01

    The structure, conformation and configuration of the n-propyl 3-azido-2,3-dideoxy-β-D-arabino-hexopyranoside (BAra-nPr) were determined by 1H NMR, 13C NMR, and IR spectroscopy, as well as by optical rotation. The crystal structure was confirmed by single-crystal X-ray diffraction studies at room temperature. The compound crystallizes in P21 space group symmetry of the monoclinic system. The molecule has a 4C1 chair conformation with azide group in the equatorial position both in a solution as well as in the crystal. The spatial arrangement of azide group is compared to other previously determined azidosugars. The hydrogen bonds between the hydroxyl group of sugar molecules lead to a ribbon structure observed also for the ethyl homolog. The packing of ribbons is dependent on the alkyl substituent length and with the elongation changes from pseudohexagonal to lamellar. Acidity constants for the n-propyl 3-azido-2,3-dideoxy-β-D-arabino-hexopyranoside (BAra-nPr) in an aqueous solution were evaluated by the spectrophotometric and potentiometric titrations methods. Title compound exhibit blue absorption with the maximum wavelengths in the range of 266 nm and 306 nm. Based on these measurements we showed equilibria existing in a particular solution and a distribution of species which have formed during the titration. We also investigated interactions between Cu(II), Ni(II) and VO(II) and title compound (as ligand L) during complexometric titration. On these bases we identified that in [CuII-BAra-nPr]2+ the ratio of the ligand L to metal ion M(II) was 3:1, while in [NiII-BAra-nPr]2+ and [VOII-BAra-nPr]2+ complexes 2:1 ratios were found. The cumulative stability constants (as log β) occurring in an aqueous solution for the complexes of BAra-nPr with Cu(II), Ni(II) and VO(IV) were 14.57; 11.71 and 4.20, respectively.

  3. Composition and structure of acid leached LiMn 2-yTi yO 4 (0.2≤ y≤1.5) spinels

    NASA Astrophysics Data System (ADS)

    Avdeev, Georgi; Amarilla, José Manuel; Rojo, José María; Petrov, Kostadin; Rojas, Rosa María

    2009-12-01

    Lithium manganese titanium spinels, LiMn 2-yTi yO 4, (0.2≤ y≤1.5) have been synthesized by solid-state reaction between TiO 2 (anatase), Li 2CO 3 and MnCO 3. Li + was leached from the powdered reaction products by treatment in excess of 0.2 N HCl at 85 °C for 6 h, under reflux. The elemental composition of the acidic solution and solid residues of leaching has been determined by complexometric titration, atomic absorption spectroscopy and X-ray fluorescence analysis. Powder X-ray diffraction was used for structural characterization of the crystalline fraction of the solid residues. It has been found that the amount of Li + leached from LiMn 2-yTi yO 4 decreases monotonically with increasing y in the interval 0.2≤ y≤1.0 and abruptly drops to negligibly small values for y>1.0. The content of Mn and Li in the liquid phase and of Mn and Ti in the solid (amorphous plus crystalline) residue, were related to the composition and cation distribution in the pristine compounds. A new formal chemical equation describing the process of leaching and a mechanism of the structural transformation undergone by the initial solids as a result of Li + removal has been proposed.

  4. Application of 2-Trichloromethylbenzimidazole in Analytical Chemistry: A Highly Selective Chromogenic Reagent for Thin-Layer Chromatography and Some Other Analytical Uses

    PubMed Central

    Konopski, Leszek; Kiełczewska, Anna

    2012-01-01

    2-Trichloromethylbenzimidazole (TCMB) was used as a chromogenic reagent in organic or inorganic analysis, mainly in thin-layer chromatography (TLC). In reactions of TCMB with some heteroaromatic nitrogen containing compounds, such as azines, azoles and benzazoles, a formation of high colored products occurred. For azines, the chromogenic reaction was highly regioselective, since the both adjacent α-positions versus the nitrogen atom(s) must not be substituted. A TLC method of detection was developed. Thirty azines, azoles, and benzazoles were detected at the detection limit 10 ng to 1 μg. This method was also applied for detection of heteroaromatic pesticides, and the attempts to construct active and passive dosimeters for nicotine were made. In a prechromatographic reaction of aromatic o-diamines with methyl trichloroacetimidate, TCMB or its derivatives were formed in situ. Followed by TLC and visualization in pyridine vapors, this procedure was applied for detection of o-phenylenediamine derivatives. The reaction product of TCMB and pyridine (LI Complex) was identified and fully characterized. Two different reaction mechanisms: with electron deficient basic heteroaromatic compounds, like pyridine, and with more acidic compounds, for example, pyrrole, were discussed. In aqueous solutions, the LI Complex may be also used as a new indicator for complexometric, adsorption and acid-base titration of inorganic compounds. PMID:22567563

  5. Further optimization of culture method for rat keratinocytes: titration of glucose and sodium chloride.

    PubMed

    Oku, H; Yamashita, M; Iwasaki, H; Chinen, I

    1999-02-01

    The present study further improved the serum-free method of culturing rat keratinocytes. To obtain the best growth of rat keratinocytes, we modified our previous serum-free medium (MCDB153 based medium), particularly the amounts of glucose and sodium chloride (NaCl). Titration experiments showed the optimal concentration to be 0.8 mM for glucose and 100 mM for NaCl. This modification eliminated the requirement for albumin, which had been essential for colony formation when our previous medium was used. Titration of glucose and NaCl, followed by adjustment of essential amino acids and growth factors, produced a new formulation. More satisfactory and better growth was achieved with the new medium than with the previous medium. Accumulation of monoalkyldiacylglycerol (MADAG) was consistently noted in this study, representing the unusual lipid profile. A tendency toward normalization was, however, noted with the neutral lipid profile of keratinocytes cultivated in the new medium: lower production of MADAG was obtained with the new formulation, rather than the previous one.

  6. Complexometric Determination of Mercury Based on a Selective Masking Reaction

    ERIC Educational Resources Information Center

    Romero, Mercedes; Guidi, Veronica; Ibarrolaza, Agustin; Castells, Cecilia

    2009-01-01

    In the first analytical chemistry course, students are introduced to the concepts of equilibrium in water solutions and classical (non-instrumental) analytical methods. Our teaching experience shows that "real samples" stimulate students' enthusiasm for the laboratory work. From this diagnostic, we implemented an optional activity at the end of…

  7. Chemistry Notes

    ERIC Educational Resources Information Center

    Pinkney, J. N.; And Others

    1976-01-01

    Describes eleven laboratory experiments, including the catalytic effect of copper in zinc-acid reaction; a study of the rate of polymerization of some aldehydes; and a demonstration automatic potentiometric titrator. (MLH)

  8. Selective Extraction of Metals from Pacific Sea Nodules with Dissolved Sulfur Dioxide

    NASA Astrophysics Data System (ADS)

    Khalafalla, Sanaa E.; Pahlman, John E.

    1981-08-01

    How to tritrate a rock? … The following article illustrates the possibility of titrating a metallic constituent in a mineral with a selective reagent to an endpoint of near complete metal extraction. A very rapid and efficient—almost instantaneous and quantitative—method has been devised to differentially leach manganese, nickel, and cobalt to the exclusion of copper and iron from deep-sea nodules.1 In this method, a given weight of raw sea nodules ground to -200 mesh in an aqueous slurry is contacted for 10 min at room temperature and ambient pressure with a specified quantity of SO2. An independent leaching parameter R has been defined as the ratio of the number of moles of SO2 in the leaching solution to the weight of sea nodules. Variation of metal extraction with R generates sigmoidal curves characteristic of the metals extracted. A threshold value of R is required to initiate the leaching of a given metal from the mixed oxides. Once this threshold is reached, the metal recovery can rise above 95% in less than 10 minutes. For increasing value of R the extractability of various metals from Pacific sea nodules by SO2 follows the order: Mn > Ni > Co ≫ Fe, Al, Cu. Disparity in the R values permits a variety of selective leaching systems and metal separations simply by changing the quantity of SO2 in the contacting solution. Success in this leaching system depends on comminuting the nodules to less than 100 mesh. Above this critical size, leaching is slowed due to the inaccessibility of the inner particle reacting groups to the SO2 leaching agent, resulting in lower and nonselective extractions of preferred metal values. Leaching with HCl solutions of the same pH level as dissolved SO2 yielded mixed, slow, and incomplete metal extractions. This finding rules out any interpretation based on hydrogen ion from the ionization of sulfurous acid as the leaching agent. The leaching curves observed in the new system resemble the complexometric titration curves of heavy metals with specific coordination species.

  9. Dose titration of BAF312 attenuates the initial heart rate reducing effect in healthy subjects

    PubMed Central

    Legangneux, Eric; Gardin, Anne; Johns, Donald

    2013-01-01

    Aim Previous studies have shown transient decreases in heart rate (HR) following administration of sphingosine 1‐phosphate (S1P) receptor modulators including BAF312. This study was conducted to determine whether dose titration of BAF312 reduces or eliminates these effects. Methods Fifty‐six healthy subjects were randomized 1:1:1:1 to receive BAF312 in one of two dose titration (DT) regimens (DT1 and DT2: 0.25–10 mg over 9–10 days), no titration (10 mg starting dose) or placebo. Pharmacodynamic and pharmacokinetic parameters were assessed. Results Neither DT1 nor DT2 resulted in clinically significant bradycardia or atrioventricular conduction effects. Both titration regimens showed a favourable difference on each of days 1–12 vs. the non‐titration regimen on day 1 for HR effects (P < 0.0001). On day 1, the geometric mean ratio of the fraction from the previous day in minimum daily HR between DT1 and non‐titration was 1.18 (95% confidence interval [CI] 1.13, 1.23) and 1.14 (95% CI 1.09, 1.18) for DT2 (both P < 0.05) with significant differences noted through to day 12. Non‐titration HRs showed considerable separation from placebo throughout the study. There was no statistically significant reduction in HR vs. placebo on day 1 in either titration regimen. On days 3–7 subjects in DT1 and DT2 experienced minor reductions in HR vs. placebo (approximately 5 beats min−1; P ≤ 0.0001). From days 9–12, HRs in both titration regimens were comparable with placebo. Conclusion Both titration regimens effectively attenuated the initial bradyarrhythmia observed on day 1 of treatment with BAF312 10 mg. PMID:22845008

  10. Science Notes.

    ERIC Educational Resources Information Center

    School Science Review, 1990

    1990-01-01

    Included are 30 science activities that include computer monitoring, fieldwork, enzyme activity, pH, drugs, calorimeters, Raoult's Law, food content, solubility, electrochemistry, titration, physical properties of materials, gel filtration, energy, concepts in physics, and electricity. (KR)

  11. Dose titration of BAF312 attenuates the initial heart rate reducing effect in healthy subjects.

    PubMed

    Legangneux, Eric; Gardin, Anne; Johns, Donald

    2013-03-01

    Previous studies have shown transient decreases in heart rate (HR) following administration of sphingosine 1-phosphate (S1P) receptor modulators including BAF312. This study was conducted to determine whether dose titration of BAF312 reduces or eliminates these effects. Fifty-six healthy subjects were randomized 1:1:1:1 to receive BAF312 in one of two dose titration (DT) regimens (DT1 and DT2: 0.25-10 mg over 9-10 days), no titration (10 mg starting dose) or placebo. Pharmacodynamic and pharmacokinetic parameters were assessed. Neither DT1 nor DT2 resulted in clinically significant bradycardia or atrioventricular conduction effects. Both titration regimens showed a favourable difference on each of days 1-12 vs. the non-titration regimen on day 1 for HR effects (P < 0.0001). On day 1, the geometric mean ratio of the fraction from the previous day in minimum daily HR between DT1 and non-titration was 1.18 (95% confidence interval [CI] 1.13, 1.23) and 1.14 (95% CI 1.09, 1.18) for DT2 (both P < 0.05) with significant differences noted through to day 12. Non-titration HRs showed considerable separation from placebo throughout the study. There was no statistically significant reduction in HR vs. placebo on day 1 in either titration regimen. On days 3-7 subjects in DT1 and DT2 experienced minor reductions in HR vs. placebo (approximately 5 beats min⁻¹; P ≤ 0.0001). From days 9-12, HRs in both titration regimens were comparable with placebo. Both titration regimens effectively attenuated the initial bradyarrhythmia observed on day 1 of treatment with BAF312 10 mg. © 2012 Novartis Institutes for BioMedical Research (NIBIR). British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  12. Multifunctional rare-Earth vanadate nanoparticles: luminescent labels, oxidant sensors, and MRI contrast agents.

    PubMed

    Abdesselem, Mouna; Schoeffel, Markus; Maurin, Isabelle; Ramodiharilafy, Rivo; Autret, Gwennhael; Clément, Olivier; Tharaux, Pierre-Louis; Boilot, Jean-Pierre; Gacoin, Thierry; Bouzigues, Cedric; Alexandrou, Antigoni

    2014-11-25

    Collecting information on multiple pathophysiological parameters is essential for understanding complex pathologies, especially given the large interindividual variability. We report here multifunctional nanoparticles which are luminescent probes, oxidant sensors, and contrast agents in magnetic resonance imaging (MRI). Eu(3+) ions in an yttrium vanadate matrix have been demonstrated to emit strong, nonblinking, and stable luminescence. Time- and space-resolved optical oxidant detection is feasible after reversible photoreduction of Eu(3+) to Eu(2+) and reoxidation by oxidants, such as H2O2, leading to a modulation of the luminescence emission. The incorporation of paramagnetic Gd(3+) confers in addition proton relaxation enhancing properties to the system. We synthesized and characterized nanoparticles of either 5 or 30 nm diameter with compositions of GdVO4 and Gd0.6Eu0.4VO4. These particles retain the luminescence and oxidant detection properties of YVO4:Eu. Moreover, the proton relaxivity of GdVO4 and Gd0.6Eu0.4VO4 nanoparticles of 5 nm diameter is higher than that of the commercial Gd(3+) chelate compound Dotarem at 20 MHz. Nuclear magnetic resonance dispersion spectroscopy showed a relaxivity increase above 10 MHz. Complexometric titration indicated that rare-earth leaching is negligible. The 5 nm nanoparticles injected in mice were observed with MRI to concentrate in the liver and the bladder after 30 min. Thus, these multifunctional rare-earth vanadate nanoparticles pave the way for simultaneous optical and magnetic resonance detection, in particular, for in vivo localization evolution and reactive oxygen species detection in a broad range of physiological and pathophysiological conditions.

  13. Aqueous solubility of calcium L-lactate, calcium D-gluconate, and calcium D-lactobionate: importance of complex formation for solubility increase by hydroxycarboxylate mixtures.

    PubMed

    Vavrusova, Martina; Munk, Merete Bøgelund; Skibsted, Leif H

    2013-08-28

    Among the calcium hydroxycarboxylates important for cheese quality, D-lactobionate [Ksp = (7.0 ± 0.3) × 10(-3) mol(3) L(-3)] and L-lactate [Ksp = (5.8 ± 0.2) × 10(-3) mol(3) L(-3)] were found more soluble than D-gluconate [Ksp = (7.1 ± 0.2) × 10(-4) mol(3) L(-3)], as indicated by the solubility products determined electrochemically for aqueous 1.0 M NaCl at 25.0 °C. Still, solubility of calcium L-lactate increases by 45% in the presence of 0.50 M sodium D-gluconate and by 37% in the presence of 0.50 M sodium D-lactobionate, while solubility of calcium D-gluconate increases by 66 and 85% in the presence of 0.50 M sodium L-lactate and 0.50 M sodium D-lactobionate, respectively, as determined by complexometric titration. Sodium L-lactate and sodium D-gluconate have only little influence on solubility of calcium D-lactobionate. The increased solubility is described quantitatively by calcium binding to D-gluconate (K1 = 14 ± 3 mol(-1) L) in 1.0 M NaCl at 25 °C, D-lactobionate (K1 = 11 ± 2 mol(-1) L), and L-lactate (K1 = 8 ± 2 mol(-1) L), as indicated by the association constants determined electrochemically. In mixed hydroxycarboxylate solutions, calcium binding is quantitatively described by the geometric mean of the individual association constants for both aqueous 1.0 and 0.20 M NaCl, indicating a 1:1 stoichiometry for complex formation.

  14. Have a Chemistry Field Day in Your Area.

    ERIC Educational Resources Information Center

    Mattson, Bruce M.; And Others

    1989-01-01

    Describes a full day of chemistry fun and competition for high school chemistry students. Notes teams have five students from each high school. Lists five competitive events for each team: titration, qualitative analysis, balancing equations, general chemistry quiz, and quantitative analysis with atomic absorption spectroscopy. (MVL)

  15. 21 CFR 172.133 - Dimethyl dicarbonate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., analytical-grade Solution of 1 N diisobutylamine in chlorobenzene, distilled 1 N Acetic Acid procedure... the 1 N diisobutylamine solution by pipette and allow to stand for 5 minutes. Subsequently, titrate...). calculation ER10MR99.023 Note: For adding the diisobutylamine solution, always use the same pipette and wait...

  16. 21 CFR 172.133 - Dimethyl dicarbonate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., analytical-grade Solution of 1 N diisobutylamine in chlorobenzene, distilled 1 N Acetic Acid procedure... the 1 N diisobutylamine solution by pipette and allow to stand for 5 minutes. Subsequently, titrate...). calculation ER10MR99.023 Note: For adding the diisobutylamine solution, always use the same pipette and wait...

  17. [Sufficiency with water-soluble vitamins and state of bone in pregnant women].

    PubMed

    Vrzhesinskaya, O A; Pereverzeva, O G; Gmoshinskaya, M V; Kodentsova, V M; Safronova, A I; Korosteleva, M M; Aleshina, I V; Fandeeva, T A

    2015-01-01

    Vitamin status and bone strength have been estimated in 91 pregnant women (29.3 ± 4.6 years old) from Moscow by non-invasive methods. Sufficiency with vitamins C, B2, B6 has been evaluated by morning urinary excretion of ascorbic acid, riboflavin and 4-piridoxic acid determined by visual titration and fluorimetric methods. The rate of bone resorption has been measured by the ratio of urinary calcium and creatinine, determined by complexometric titration and spectrophotometrically. The study of the bone strength has been conducted using an ultrasonic densitometer (the speed of the ultrasonic waves along the cortical layer). The lack of vitamin C was found in 20.4% .of the women surveyed, vitamin B2--in 27.4%. Vitamin B6 deficiency was detected most frequently (90%). Excretion of vitamins B2 and B6 in women in the third trimester of pregnancy was lower as compared with the women in the first and second trimester. In 53.3% of the women surveyed an increase in urinary excretion of calcium per creatinine has been observed. Excretion of group B vitamins (especially vitamin B6, 1.75 fold, p < 0.05) in women taking vitamin supplements was higher compared to non-taking vitamins that indicates the better sufficiency of the organism with these vitamins. Among women who took vitamin complexes, inadequate supply with water-soluble vitamins C, B2 and B6 was detected less frequently (the difference was significant for vitamin B2) than among women who did not intake vitamin complexes (in 11.9, 27.7 and 42.4% vs 16.1, 54.8 and 48.8 %). The rate of bone resorption (Ca/creatinine) in women taking vitamins was smaller (0.19 ± 0.09 vs 0.24 ± 0.14, p > 0.05). Ca/creatinine ratio was within normal range in 40% of women who intake vitamins, while in women not taking vitamins--only in 22.2%; this value exceeded the upper limit of norm in the rest. The strength of bone was broken in women in the second and third trimester of pregnancy, having worse supply of vitamins. The percentage of agreement of the results of osteopenia diagnosis assessment (ultrasound densitometry and urinary Ca/creatinine) was 42.2%. Thus, the conclusion has been confirmed that the evaluation of the status of bone is possible only basing on the results of determination of several parameters.

  18. Placebo-controlled pilot trial testing dose titration and intravenous, intramuscular and subcutaneous routes for ketamine in depression.

    PubMed

    Loo, C K; Gálvez, V; O'Keefe, E; Mitchell, P B; Hadzi-Pavlovic, D; Leyden, J; Harper, S; Somogyi, A A; Lai, R; Weickert, C S; Glue, P

    2016-07-01

    This pilot study assessed the feasibility, efficacy and safety of an individual dose-titration approach, and of the intravenous (IV), intramuscular (IM) and subcutaneous (SC) routes for treating depression with ketamine. Fifteen treatment-refractory depressed participants received ketamine or midazolam (control treatment) in a multiple crossover, double-blind study. Ketamine was administered by IV (n = 4), IM (n = 5) or SC (n = 6) injection. Dose titration commenced at 0.1 mg/kg, increasing by 0.1 mg/kg up to 0.5 mg/kg, given in separate treatment sessions separated by ≥1 week, with one placebo control treatment randomly inserted. Mood, psychotomimetic and hemodynamic effects were assessed and plasma ketamine concentrations assayed. Twelve participants achieved response and remission criteria, achieved at doses as low as 0.1 mg/kg. All three routes of administration resulted in comparable antidepressant effects. Fewest adverse effects were noted with the SC route. Antidepressant response, adverse effects and ketamine concentrations were dose-related. Antidepressant response occurred at a range of doses and at <0.5 mg/kg. The dose-titration approach is a practical method for optimizing the efficacy - side-effects trade-off on an individual patient basis. This pilot study provides preliminary evidence for SC injection as a practical, feasible and efficacious treatment approach. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. A Novel Ion - selective Polymeric Membrane Sensor for Determining Thallium(I) With High Selectivity

    NASA Astrophysics Data System (ADS)

    Kassim, Anuar; Rezayi, Majid; Ahmadzadeh, Saeid; Rounaghi, Gholamhossein; Mohajeri, Masoomeh; Azah Yusof, Noor; Tee, Tan Wee; Yook Heng, Lee; Halim Abdullah, Abd

    2011-02-01

    Thallium is a toxic metal that introduced into the environment mainly as a waste from the production of zinc, cadmium, and lead and by combustion of coal. Thallium causes gastrointestinal irritation and nerve damage when people are exposed to it for relatively short period of time. For long term, thallium has the potential to cause the following effects: change in blood chemistry, damage to liver, kidney, intestinal and testicular tissue, and hair loss. In this work a membrane was prepared by use of 4'-nitrobenzo -18-crown-6 (4'NB18C6) as an ion carrier, polyvinylchloride (PVC) as a matrix, and diocthylphetalate (DOP) as a plasticizer for making an ion selective electrode for measurement of Tl+ cation in solutions. The amount of 4'-nitrobenzo-18C6 and polyvinylchloride were optimized in the preparation of the membrane. The response of the electrode was Nernstian within the concentration range 1.0 × 10-8 to 1.0 × 10-1M. This sensor displays a drift in Nernstian response for this cation with increasing the amount of ionophore and decreasing the amount of polyvinylchloride.The results of potentiometric measurements showed that, this electrode also responses to Cu2+ Ni2+ and Pb2+ cations, but the electrode has a wider dynamic range and a lower detection limit to Tl+ cation. The effects of various parameters such as pH, different cations interferences, effect of the amount of ionophore and polyvinylchloride and time on response of the coated ion selective electrode were investigated. Finally the constructed electrode was used in complexometric and precipitation titrations of Tl+ cation with EDTA and KBr, respectively. The response of the fabricated electrode at concentration range from 1.0 × 10-8 to 1.0 × 10-1M is linear with a Nernstian slope of 57.27 mV.

  20. Determining association constants from titration experiments in supramolecular chemistry.

    PubMed

    Thordarson, Pall

    2011-03-01

    The most common approach for quantifying interactions in supramolecular chemistry is a titration of the guest to solution of the host, noting the changes in some physical property through NMR, UV-Vis, fluorescence or other techniques. Despite the apparent simplicity of this approach, there are several issues that need to be carefully addressed to ensure that the final results are reliable. This includes the use of non-linear rather than linear regression methods, careful choice of stoichiometric binding model, the choice of method (e.g., NMR vs. UV-Vis) and concentration of host, the application of advanced data analysis methods such as global analysis and finally the estimation of uncertainties and confidence intervals for the results obtained. This tutorial review will give a systematic overview of all these issues-highlighting some of the key messages herein with simulated data analysis examples.

  1. Characterization of Bacillus megaterium, Bacillus pumilus, and Paenibacillus polymyxa isolated from a Pinot noir wine from Western Washington State.

    PubMed

    von Cosmos, Nicolas H; Watson, Bruce A; Fellman, J K; Mattinson, D S; Edwards, Charles G

    2017-10-01

    This report provides the first confirmed evidence of Bacillus-like bacteria present in a wine from Washington State. These bacteria were isolated from a 2013 Pinot noir wine whose aroma was sensorially described as being 'dirty' or 'pond scum.' Based on physiological traits and genetic sequencing, three bacterial isolates were identified as Bacillus megaterium (strain NHO-1), Bacillus pumilus (strain NHO-2), and Paenibacillus polymyxa (strain NHO-3). These bacteria grew in synthetic media of low pH (pH 3.5) while some survived ethanol concentrations up to 15% v/v. However, none tolerated molecular SO 2 concentrations ≥0.4 mg/l. Growth of strains NHO-1 and NHO-3 in a Merlot grape juice resulted in increases of titratable and volatile acidities while decreases in titratable acidity were noted for NHO-2. Copyright © 2017. Published by Elsevier Ltd.

  2. Whey-grape juice drink processed by supercritical carbon dioxide technology: Physicochemical characteristics, bioactive compounds and volatile profile.

    PubMed

    Amaral, Gabriela V; Silva, Eric Keven; Cavalcanti, Rodrigo N; Martins, Carolina P C; Andrade, Luiz Guilherme Z S; Moraes, Jeremias; Alvarenga, Verônica O; Guimarães, Jonas T; Esmerino, Erick A; Freitas, Mônica Q; Silva, Márcia C; Raices, Renata S L; Sant' Ana, Anderson S; Meireles, M Angela A; Cruz, Adriano G

    2018-01-15

    The effect of supercritical carbon dioxide technology (SCCD, 14, 16, and 18MPa at 35±2°C for 10min) on whey-grape juice drink characteristics was investigated. Physicochemical characterization (pH, titratable acidity, total soluble solids), bioactive compounds (phenolic compounds, anthocyanin, DPPH and ACE activity) and the volatile compounds were performed. Absence of differences were found among treatments for pH, titratable acidity, soluble solids, total anthocyanin and DPPH activity (p-value>0.05). A direct relationship between SCCD pressure and ACE inhibitory activity was observed, with 34.63, 38.75, and 44.31% (14, 16, and 18MPa, respectively). Regards the volatile compounds, it was noted few differences except by the presence of ketones. The findings confirm the SCCD processing as a potential promising technology to the conventional thermal treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Oxygen in the Setting of Acute Myocardial Infarction: Is It Really a Breath of Fresh Air?

    PubMed

    Loomba, Rohit S; Nijhawan, Karan; Aggarwal, Saurabh; Arora, Rohit R

    2016-03-01

    Supplemental oxygen has been used in the setting of acute myocardial infarction (AMI). Once an official recommendation in the guidelines for the management of acute ST-segment elevation myocardial infarction, it is now mentioned as an intervention to be considered. Data for the use of supplemental oxygen or AMI are limited, and some data have suggested associated harm. We performed a systematic review of the literature and a subsequent meta-analysis of the data to determine the effect of high concentration oxygen versus titrated oxygen or room air in the setting of AMI. The following end points were studied: in-hospital mortality, opiate use, percentage of infarcted myocardium by magnetic resonance imaging (MRI), and mass of infarcted myocardium by MRI. No significant difference was noted with end points when comparing those randomized to high-concentration oxygen versus those randomized to titrated oxygen or room air in the setting of AMI. No significant publication bias was identified although this could not be assessed for all end points. High-concentration oxygen may not offer any benefit when compared to titrated oxygen or room air. A large, randomized trial is warranted to further delineate these differences with respect to multiple end points. © The Author(s) 2015.

  4. Time course and predictors of health-related quality of life improvement and medication satisfaction in children diagnosed with attention-deficit/hyperactivity disorder treated with the methylphenidate transdermal system.

    PubMed

    Frazier, Thomas W; Weiss, Margaret; Hodgkins, Paul; Manos, Michael J; Landgraf, Jeanne M; Gibbins, Christopher

    2010-10-01

    The aim of this study was to evaluate the time course and predictors of improvement in health-related quality of life (HRQL) and medication satisfaction in children diagnosed with attention-deficit/hyperactivity disorder (ADHD) and treated with the methylphenidate transdermal system (MTS). Temporal relationships between ADHD symptoms, medication satisfaction, and HRQL measures were examined via latent growth curve, structural path, and growth mixture models. Higher levels of medication satisfaction at the end of titration predicted greater increases in family HRQL (p=0.004) and, to a lesser extent, child HRQL (p=0.068) throughout the study. At 4 of 6 (p<0.05) and 5 of 6 (p<0.10) contemporaneous time points, ADHD symptoms predicted child HRQL. At 2 of 6 (p<0.05) and 3 of 6 (p<0.10) contemporaneous time points, ADHD symptoms predicted family HRQL. ADHD did not predict child or family HRQL improvements at subsequent time points. A uniform pattern of change for child HRQL was noted, with most HRQL change following the pattern of symptom change during titration. Three distinct patterns of change were noted for family HRQL. In most cases, medication satisfaction, ADHD symptoms, and HRQL improved simultaneously, suggesting that HRQL was not a delayed response to improvement in symptoms. Children showed a uniform pattern of improvement in HRQL that followed symptom change; three distinct patterns of change were found for improvement in family HRQL.

  5. Patient emotions and perceptions of antiepileptic drug changes and titration during treatment for epilepsy.

    PubMed

    Fishman, Jesse; Cohen, Greg; Josephson, Colin; Collier, Ann Marie; Bharatham, Srikanth; Zhang, Ying; Wild, Imane

    2017-04-01

    To investigate the impact of antiepileptic drug (AED) change and dose titration on the emotional well-being of patients with epilepsy. Members of an online epilepsy community were invited to voluntarily participate in an online survey. The cross-sectional anonymous survey consisted of 31 multiple choice questions balanced in terms of variety and positivity/negativity of emotions concerning participants' most recent AED change. To substantiate survey results, spontaneous comments from epilepsy-related online forums and social media websites that mentioned participants' experiences with AED medication changes (termed passive listening statements) were analyzed and categorized by theme. All 345 survey participants (270 [78.3%] female; 172 [49.9%] were 26-45years old) self-reported an epilepsy/seizure diagnosis and were currently taking seizure medication; 263 (76.2%) were taking ≥2 AEDs and 301 (87.2%) had ≥1 seizure in the previous 18months. All participants reported a medication change within the previous 12months (dose increased [153 participants (44.3%)], medication added [105 (30.4%)], dose decreased [49 (14.2%)], medication removed [38 (11.0%)]). Improving seizure control (247 [71.6%]) and adverse events (109 [31.6%]) were the most common reasons for medication change. Primary emotions most associated (≥10% of participants) with an AED regimen change were (before medication change; during/after medication change) hopefulness (50 [14.5%]; 43 [12.5%]), uncertainty (50 [14.5%]; 69 [20.0%]), and anxiety (35 [10.1%]; 45 [13.0%]), and were largely due to concerns whether the change would work (212/345 [61.4%]; 180/345 [52.2%]). In the text analysis segment aimed at validating the survey, 230 participants' passive listening statements about medication titration were analyzed; additional seizure activity during dose titration (93 [40.4%]), adverse events during titration (71 [30.9%]), higher medication dosages (33 [14.3%]), and drug costs (25 [10.9%]) were the most commonly noted concerns. Although the emotional well-being of patients with epilepsy is complex, our study results suggest that participants report their emotional well-being as negatively affected by changes in AED regimen, with most patients reporting uncertainty regarding the outcome of such a change. Future research is warranted to explore approaches to alleviate patient concerns associated with AED medication changes. Copyright © 2017 Ellen Carey, UCB Brussels, Belgium. Published by Elsevier Inc. All rights reserved.

  6. Microscale Titration in Schools Titration Competition.

    ERIC Educational Resources Information Center

    Clark, Michael J.

    1998-01-01

    Reviews the requirements of the National Titration Competition and describes how a team in a local competition used the technique. Compares microscale titration to conventional titration. Outlines the benefits of employing microscale techniques. (DDR)

  7. Optimal level of continuous positive airway pressure: auto-adjusting titration versus titration with a predictive equation.

    PubMed

    Choi, Ji Ho; Jun, Young Joon; Oh, Jeong In; Jung, Jong Yoon; Hwang, Gyu Ho; Kwon, Soon Young; Lee, Heung Man; Kim, Tae Hoon; Lee, Sang Hag; Lee, Seung Hoon

    2013-05-01

    The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation - with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O,respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of +/- 1 cm H2O (p > 0.999). When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.

  8. Determination of biguanide groups in polyhexamethylene biguanide hydrochloride by titrimetric methods.

    PubMed

    Hattori, Toshiaki; Nakata, Yasuko; Kato, Ryo

    2003-11-01

    The biguanide concentration of polyhexamethylene biguanide hydrochloride (PHMB-HCl) was measured by non-aqueous titration with HClO4, argentometric titration, the Kjeldhal method, and colloidal titration. The summation value of non-aqueous titration and argentometric titration corresponded to two titrable nitrogens in five nitrogens per one unit of PHMB-HCl, and consisted with the result of the Kjeldhal method to the five nitrogens. The colloidal titration of PHMB-HCl at pH 2.05 was equal to that with the two nitrogens. The relative standard deviations of non-aqueous titration, argentometric titration, the Kjeldhal method, and colloidal titration were 0.50% for 8 runs, 0.13% for 7 runs, 3.61% for 6 runs, and 0.69% for 6 runs, respectively.

  9. Developments in Titrimetry.

    ERIC Educational Resources Information Center

    Parry-Jones, R.

    1980-01-01

    Described are some new uses and procedures of titration procedures. Topics included are titration in non-aqueous solvents, thermometric titration and catalytic methods for end-point detection, titration finish in organic elemental analysis, and sub-micro analysis and automatic titration procedures. (CS)

  10. Thermometric titration in investigation of the formation of polyanions of molybdenum(VI), tungsten(VI), vanadium(V), and chromium (VI)-I: comparison of thermometric and potentiometric titration curves.

    PubMed

    Kiba, N; Takeuchi, T

    1973-09-01

    A new twin-cell thermometric titrator has been devised and used for thermometric titration of solutions of sodium molybdate, sodium tungstate, sodium orthovanadate, ammonium metavanadate, and potassium chromate with perchloric acid. The thermometric titration curves were compared with corresponding pH-titration curves for elucidation of the reactions occurring in the titrations. Thermometric titrimetric methods have been developed for the determination of tungsten, vanadium and chromium.

  11. Evidence of Multi-Component Ion Exchange in Dolomite Formation during Low Salinity Waterflooding

    NASA Astrophysics Data System (ADS)

    Srisuriyachai, Falan; Meekangwal, Suthida

    2017-12-01

    Low salinity waterflooding is a technique performed in many oil reservoirs around the globe. The technique is simply implemented by injecting water with very low ionic activity compared to formation water into an injection well. The injected water will increase reservoir pressure that is compulsory to drive oil moving toward production well. More than just maintaining reservoir pressure as obtained from conventional waterflooding, low salinity water creates shifting of surface condition, resulting in additional amount of liberated oil. Nevertheless, exact oil recovery mechanisms are still discussed. Among these proposed mechanisms, Multi-component Ion Exchange (MIE) together with wettability alteration is believed to be a major mechanism leading to higher oil recovery compared to conventional waterflooding. In this study, detection of calcium and magnesium ions which are Potential Determining Ions (PDI) for carbonate reservoirs are detected during the coreflood experiment. Dolomite rock sample is used to represent carbonate formation and detection of previously mentioned ions is performed by complexometric titration of the effluents. From the study, it is observed that during conventional waterflooding and low salinity waterflooding at low temperature of 30 degrees Celsius, calcium and magnesium ions in the produced water is increased compared to the amount of these ions in the injected water. This incremental of ions can be explained by the dissolution of calcium and magnesium from dolomite which is chemically composed of calcium magnesium carbonate. At this temperature, the portion of calcium ion is always less than magnesium ion even though the amount of calcium ion is higher than magnesium ion in injected water. However, at higher temperatures which are 50 and 70 degrees Celsius, ratio of calcium and magnesium ions in injected and produced water is reversed. Disappearance of magnesium ion in the effluent is more obvious especially at 70 degrees Celsius and by low salinity waterflooding. This can be explained that at lower temperature, calcium ion disappears to form of calcium carboxylate complex with oil and at higher temperature, magnesium ion disappears as magnesium can start to form magnesium carboxylate complex with oil and hence, the amount of both calcium and magnesium ions is decreased compared to lower temperature. In dolomite reservoir, since both calcium ions and magnesium ions are provided from dissolution mechanism, the benefit from multi-component ion exchange will occur at high temperature as both calcium and magnesium ions will be consumed for oil recovery mechanism.

  12. Thermometric titration of sulphate.

    PubMed

    Williams, M B; Janata, J

    1970-06-01

    Direct thermometric titration of sulphate with a solution of barium perchlorate is proposed. The stoichiometry of the titration is shown to be critically dependent on the concentration of ethanol in the titration medium. The titration is rapid and suffers from only a few interferences.

  13. A novel approach for high precision rapid potentiometric titrations: application to hydrazine assay.

    PubMed

    Sahoo, P; Malathi, N; Ananthanarayanan, R; Praveen, K; Murali, N

    2011-11-01

    We propose a high precision rapid personal computer (PC) based potentiometric titration technique using a specially designed mini-cell to carry out redox titrations for assay of chemicals in quality control laboratories attached to industrial, R&D, and nuclear establishments. Using this technique a few microlitre of sample (50-100 μl) in a total volume of ~2 ml solution can be titrated and the waste generated after titration is extremely low comparing to that obtained from the conventional titration technique. The entire titration including online data acquisition followed by immediate offline analysis of data to get information about concentration of unknown sample is completed within a couple of minutes (about 2 min). This facility has been created using a new class of sensors, viz., pulsating sensors developed in-house. The basic concept in designing such instrument and the salient features of the titration device are presented in this paper. The performance of the titration facility was examined by conducting some of the high resolution redox titrations using dilute solutions--hydrazine against KIO(3) in HCl medium, Fe(II) against Ce(IV) and uranium using Davies-Gray method. The precision of titrations using this innovative approach lies between 0.048% and 1.0% relative standard deviation in different redox titrations. With the evolution of this rapid PC based titrator it was possible to develop a simple but high precision potentiometric titration technique for quick determination of hydrazine in nuclear fuel dissolver solution in the context of reprocessing of spent nuclear fuel in fast breeder reactors. © 2011 American Institute of Physics

  14. A novel approach for high precision rapid potentiometric titrations: Application to hydrazine assay

    NASA Astrophysics Data System (ADS)

    Sahoo, P.; Malathi, N.; Ananthanarayanan, R.; Praveen, K.; Murali, N.

    2011-11-01

    We propose a high precision rapid personal computer (PC) based potentiometric titration technique using a specially designed mini-cell to carry out redox titrations for assay of chemicals in quality control laboratories attached to industrial, R&D, and nuclear establishments. Using this technique a few microlitre of sample (50-100 μl) in a total volume of ˜2 ml solution can be titrated and the waste generated after titration is extremely low comparing to that obtained from the conventional titration technique. The entire titration including online data acquisition followed by immediate offline analysis of data to get information about concentration of unknown sample is completed within a couple of minutes (about 2 min). This facility has been created using a new class of sensors, viz., pulsating sensors developed in-house. The basic concept in designing such instrument and the salient features of the titration device are presented in this paper. The performance of the titration facility was examined by conducting some of the high resolution redox titrations using dilute solutions--hydrazine against KIO3 in HCl medium, Fe(II) against Ce(IV) and uranium using Davies-Gray method. The precision of titrations using this innovative approach lies between 0.048% and 1.0% relative standard deviation in different redox titrations. With the evolution of this rapid PC based titrator it was possible to develop a simple but high precision potentiometric titration technique for quick determination of hydrazine in nuclear fuel dissolver solution in the context of reprocessing of spent nuclear fuel in fast breeder reactors.

  15. Multi-complexity measures of heart rate variability and the effect of vasopressor titration: a prospective cohort study of patients with septic shock.

    PubMed

    Brown, Samuel M; Sorensen, Jeffrey; Lanspa, Michael J; Rondina, Matthew T; Grissom, Colin K; Shahul, Sajid; Mathews, V J

    2016-10-10

    Septic shock is a common and often devastating syndrome marked by severe cardiovascular dysfunction commonly managed with vasopressors. Whether markers of heart rate complexity before vasopressor up-titration could be used to predict success of the up-titration is not known. We studied patients with septic shock requiring vasopressor, newly admitted to the intensive care unit. We measured the complexity of heart rate variability (using the ratio of fractal exponents from detrended fluctuation analysis) in the 5 min before all vasopressor up-titrations in the first 24 h of an intensive care unit (ICU) admission. A successful up-titration was defined as one that did not require further up-titration (or decrease in mean arterial pressure) for 60 min. We studied 95 patients with septic shock, with a median APACHE II of 27 (IQR: 20-37). The median number of up-titrations, normalized to 24 h, was 12.2 (IQR: 8-17) with a maximum of 49. Of the up-titrations, the median proportion of successful interventions was 0.28 (IQR: 0.12-0.42). The median of mean arterial pressure (MAP) at the time of a vasopressor up-titration was 66 mmHg; the average infusion rate of norepinephrine at the time of an up-titration was 0.11 mcg/kg/min. The ratio of fractal exponents was not associated with successful up-titration on univariate or multivariate regression. On exploratory secondary analyses, however, the long-term fractal exponent was associated (p = 0.003) with success of up-titration. Independent of heart rate variability, MAP was associated (p < 0.001) with success of vasopressor up-titration, while neither Sequential Organ Failure Assessment (SOFA) nor Acute Physiology and Chronic Health Evaluation II (APACHE II) score was associated with vasopressor titration. Only a third of vasopressor up-titrations were successful among patients with septic shock. MAP and the long-term fractal exponent were associated with success of up-titration. These two, complementary variables may be important to the development of rational vasopressor titration protocols.

  16. Spectrophotometric determination of titanium with tannin and thioglycollic acid and its application to titanium-treated steels and ferrous and non-ferrous alloys.

    PubMed

    Banerjee, S

    1986-04-01

    A sensitive spectrophotometric method for the determination of titanium by formation of its complex with tannin and thioglycollic acid at pH 4 has been developed. The intense yellow colour is measured at 400 nm and the system obeys Beer's law over the range 0.2-5 ppm titanium in the solution measured. The method is applicable to titanium-treated steels, stainless steels, permanent magnet alloys and duralumin alloys. The interference of Co, Ni, Cr, Mn, V, Mo and W can be eliminated by prior separation of titanium by controlled addition of cupferron in the presence of thioglycollic acid (TGA). Copper can be quantitatively separated by precipitation with TGA and determined complexometrically with EDTA, with PAN as indicator. Niobium interferes even in traces.

  17. Determining a Solubility Product Constant by Potentiometric Titration to Increase Students' Conceptual Understanding of Potentiometry and Titrations

    ERIC Educational Resources Information Center

    Grabowski, Lauren E.; Goode, Scott R.

    2017-01-01

    Potentiometric titrations are widely taught in first-year undergraduate courses to connect electrochemistry, stoichiometry, and equilibria and to reinforce acid-base titrations. Students perform a potentiometric titration that is then analyzed to determine analyte concentrations and the solubility product constant of the solid species.

  18. Theoretical problems associated with the use of acetic anhydride as a co-solvent for the non-aqueous titration of hydrohalides of organic bases and quaternary ammonium salts.

    PubMed

    Völgyi, Gergely; Béni, Szabolcs; Takács-Novák, Krisztina; Görög, Sándor

    2010-01-05

    A potentiometric titration study of organic base hydrohalides and quaternary ammonium salts using perchloric acid as the titrant and a mixture of acetic anhydride and acetic acid as the solvent was carried out and the titration mixture was analysed by NMR in order to clarify the chemistry of the reactions involved. It was found that in contrast to the general belief the formation of acetyl halides and titratable free acetate ion does not take place prior to the titration but NMR spectra proved the formation of acetyl halides in the course of the titration. This observation and the fact that the shape of the titration curves depends on the nature of the hydrohaloic acid bound to the base or of the anion in the quaternary ammonium salts led to the conclusion that the titrating agent is acetyl perchlorate formed in situ during the titration. Equations of the reactions involved in the titration process are shown in the paper.

  19. TITRATION: A Randomized Study to Assess 2 Treatment Algorithms with New Insulin Glargine 300 units/mL.

    PubMed

    Yale, Jean-François; Berard, Lori; Groleau, Mélanie; Javadi, Pasha; Stewart, John; Harris, Stewart B

    2017-10-01

    It was uncertain whether an algorithm that involves increasing insulin dosages by 1 unit/day may cause more hypoglycemia with the longer-acting insulin glargine 300 units/mL (GLA-300). The objective of this study was to compare safety and efficacy of 2 titration algorithms, INSIGHT and EDITION, for GLA-300 in people with uncontrolled type 2 diabetes mellitus, mainly in a primary care setting. This was a 12-week, open-label, randomized, multicentre pilot study. Participants were randomly assigned to 1 of 2 algorithms: they either increased their dosage by 1 unit/day (INSIGHT, n=108) or the dose was adjusted by the investigator at least once weekly, but no more often than every 3 days (EDITION, n=104). The target fasting self-monitored blood glucose was in the range of 4.4 to 5.6 mmol/L. The percentages of participants reaching the primary endpoint of fasting self-monitored blood glucose ≤5.6 mmol/L without nocturnal hypoglycemia were 19.4% (INSIGHT) and 18.3% (EDITION). At week 12, 26.9% (INSIGHT) and 28.8% (EDITION) of participants achieved a glycated hemoglobin value of ≤7%. No differences in the incidence of hypoglycemia of any category were noted between algorithms. Participants in both arms of the study were much more satisfied with their new treatment as assessed by the Diabetes Treatment Satisfaction Questionnaire. Most health-care professionals (86%) preferred the INSIGHT over the EDITION algorithm. The frequency of adverse events was similar between algorithms. A patient-driven titration algorithm of 1 unit/day with GLA-300 is effective and comparable to the previously tested EDITION algorithm and is preferred by health-care professionals. Copyright © 2017 Diabetes Canada. Published by Elsevier Inc. All rights reserved.

  20. Droplet-counting Microtitration System for Precise On-site Analysis.

    PubMed

    Kawakubo, Susumu; Omori, Taichi; Suzuki, Yasutada; Ueta, Ikuo

    2018-01-01

    A new microtitration system based on the counting of titrant droplets has been developed for precise on-site analysis. The dropping rate was controlled by inserting a capillary tube as a flow resistance in a laboratory-made micropipette. The error of titration was 3% in a simulated titration with 20 droplets. The pre-addition of a titrant was proposed for precise titration within an error of 0.5%. The analytical performances were evaluated for chelate titration, redox titration and acid-base titration.

  1. [Comparison of different continuous positive airway pressure titration methods for obstructive sleep apnea hypopnea syndrome].

    PubMed

    Li, Jingjing; Ye, Jingying; Zhang, Peng; Kang, Dan; Cao, Xin; Zhang, Yuhuan; Ding, Xiu; Zheng, Li; Li, Hongguang; Bian, Qiuli

    2014-10-01

    To explore whether there were differences between the results of automatic titration and the results of manual titration for positive airway pressure treatment in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors, the results might provide a theoretical basis for the rational use of two pressure titration methods. Sixty one patients with OSAHS were included in this study. All patients underwent a manual titration and an automatic titration within one week. The clinical informations, polysomnography data, and the results of both two titration of all patients were obtained for analysis. The overall apnea/hypopnea index was (63.1 ± 17.7)/h, with a range of 14.9/h to 110.4/h. The treatment pressure of manual titration was (8.4 ± 2.1) cmH(2)O, which was significantly lower than the treatment pressure of automatic titration, (11.5 ± 2.7) cmH(2)O (t = -9.797, P < 0.001). After using a ΔP of 3 cmH(2)O for the cutoff value (ΔP was defined as the difference of automatic titration and manual titration), it was found that the pressure of automatic titration was significantly higher in patients with a ΔP > 3 cmH(2)O than in patients with a ΔP ≤ 3 cmH(2)O, which was (13.3 ± 2.3) cmH(2)O vs (10.0 ± 2.0) cmH(2)O (t = -6.159, P < 0.001). However, there were no differences for the pressure of manual titration between these two groups, which was (8.6 ± 2.4) cmH(2)O vs (8.3 ± 2.0)cmH(2)O (P > 0.05). There was no significant difference in age, body mass index, neck circumference, abdomen circumference, apnea hypopnea index, and arterial oxygen saturation between these two groups. The treatment pressure of automatic titration is usually higher than that of manual titration. For patients with a high treatment pressure which is derived from automatic titration, a suggestion about manual titration could be given to decrease the potential treatment pressure of continuous positive airway pressure, which may be helpful in improving the comfortableness and the compliance of this treatment.

  2. A new approach to flow-batch titration. A monosegmented flow titrator with coulometric reagent generation and potentiometric or biamperometric detection.

    PubMed

    de Aquino, Emerson Vidal; Rohwedder, Jarbas José Rodrigues; Pasquini, Celio

    2006-11-01

    Monosegmented flow analysis (MSFA) has been used as a flow-batch system to produce a simple, robust, and mechanized titrator that enables true titrations to be performed without the use of standards. This paper also introduces the use of coulometry with monosegmented titration by proposing a versatile flow cell. Coulometric generation of the titrand is attractive for titrations performed in monosegmented systems, because the reagent can be added without increasing the volume of sample injected. Also, biamperomeric and potentiometric detection of titration end-points can increase the versatility of the monosegmented titrator. The cell integrates coulometric generation of the titrand with detection of end-point by potentiometry or biamperometry. The resulting titrator is a flow-batch system in which the liquid monosegment, constrained by the interfaces of the gaseous carrier stream, plays the role of a sample of known volume to be titrated. The system has been used for determination of ascorbic acid, by coulometric generation of I2 with biamperometric detection, and for determination of Fe(II), by coulometric generation of Ce(IV) with potentiometric detection of the end-point, both in feed supplements.

  3. Comparison of manual versus automatic continuous positive airway pressure titration and the development of a predictive equation for therapeutic continuous positive airway pressure in Chinese patients with obstructive sleep apnoea.

    PubMed

    Luo, Jiaying; Xiao, Sichang; Qiu, Zhihui; Song, Ning; Luo, Yuanming

    2013-04-01

    Whether the therapeutic nasal continuous positive airway pressure (CPAP) derived from manual titration is the same as derived from automatic titration is controversial. The purpose of this study was to compare the therapeutic pressure derived from manual titration with automatic titration. Fifty-one patients with obstructive sleep apnoea (OSA) (mean apnoea/hypopnoea index (AHI) = 50.6 ± 18.6 events/h) who were newly diagnosed after an overnight full polysomnography and who were willing to accept CPAP as a long-term treatment were recruited for the study. Manual titration during full polysomnography monitoring and unattended automatic titration with an automatic CPAP device (REMstar Auto) were performed. A separate cohort study of one hundred patients with OSA (AHI = 54.3 ± 18.9 events/h) was also performed by observing the efficacy of CPAP derived from manual titration. The treatment pressure derived from automatic titration (9.8 ± 2.2 cmH(2)O) was significantly higher than that derived from manual titration (7.3 ± 1.5 cmH(2)O; P < 0.001) in 51 patients. The cohort study of 100 patients showed that AHI was satisfactorily decreased after CPAP treatment using a pressure derived from manual titration (54.3 ± 18.9 events/h before treatment and 3.3 ± 1.7 events/h after treatment; P < 0.001). The results suggest that automatic titration pressure derived from REMstar Auto is usually higher than the pressure derived from manual titration. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  4. Computer controlled titration with piston burette or peristaltic pump - a comparison.

    PubMed

    Hoffmann, W

    1996-09-01

    The advantages and problems of the use of piston burettes and peristaltic pumps for dosage of titrant solutions in automatic titrations are shown. For comparison, only the dosing devices were exchanged and all other components and conditions remained unchanged. The results of continuous acid base titration show good agreement and comparable reproducibility. Potentiometric sensors (glass electrodes) with different equilibration behaviour influence the results. The capability of such electrodes was tested. Conductometric measurements allow a much faster detection because there is no equilibration of electrodes. Piston burettes should be used for titration with very high precision, titration with organic solvents and slow titrations. Peristaltic pumps seem to be more suitable for continuous titrations and long time operation without service.

  5. Homemade Equipment for the Teaching of Electrochemistry at Advanced Level: Part III.

    ERIC Educational Resources Information Center

    Chan, K. M.

    1985-01-01

    Describes: (1) thermometric titrations; (2) EM-5 equipment (consisting of a thermal sensor, calorimeter, and input-buffered amplifier); (3) acid-base titrations; (4) precipitation titrations; and (5) redox titrations. Detailed procedures are included. (JN)

  6. Protometric thermometric titrations of sparingly soluble compounds in water in the presence of n-octanol.

    PubMed

    Burgot, G; Burgot, J-L

    2002-10-15

    Thermometric titrimetry permits titration of acido-basic compounds in water in the presence of n-octanol. n-Octanol permits the solubilization of protolytes and moreover may also displace the equilibria of the titration reactions. Hydrochlorides of highly insoluble derivatives such as phenothiazine derivatives can be titrated with satisfactory accuracy and precision by sodium hydroxide despite their high pK(a) values. Likewise barbiturate salts can be titrated by hydrochloric acid. In the case of some salts, the methodology may permit the sequential titration of the ion and counter ion. Copyright 2002 Elsevier Science B.V.

  7. Risks and Benefits of Rapid Clozapine Titration.

    PubMed

    Lochhead, Jeannie D; Nelson, Michele A; Schneider, Alan L

    2016-05-18

    Clozapine is often considered the gold standard for the treatment of schizophrenia. Clinical guidelines suggest a gradual titration over 2 weeks to reduce the risks of adverse events such as seizures, hypotension, agranulocytosis, and myocarditis. The slow titration often delays time to therapeutic response. This raises the question of whether, in some patients, it may be safe to use a more rapid clozapine titration. The following case illustrates the potential risks associated with the use of multiple antipsychotics and rapid clozapine titration. We present the case of a young man with schizophrenia who developed life threatening neuroleptic malignant syndrome (NMS) during rapid clozapine titration and treatment with multiple antipsychotics. We were unable to find another case in the literature of NMS associated with rapid clozapine titration. This case is meant to urge clinicians to carefully evaluate the risks and benefits of rapid clozapine titration, and to encourage researchers to further evaluate the safety of rapid clozapine titration. Rapid clozapine titration has implications for decreasing health care costs associated with prolonged hospitalizations, and decreasing the emotional suffering associated with uncontrolled symptoms of psychosis. Clozapine is considered the most effective antipsychotic available thus efforts should focus on developing strategies that would allow for safest and most efficient use of clozapine to encourage its utilization for treatment resistance schizophrenia.

  8. Insights into optimal basal insulin titration in type 2 diabetes: Results of a quantitative survey.

    PubMed

    Berard, Lori; Bonnemaire, Mireille; Mical, Marie; Edelman, Steve

    2018-02-01

    Basal insulin (BI) treatment initiation and dose titration in type 2 diabetes (T2DM) are often delayed. Such "clinical inertia" results in poor glycaemic control and high risk of long-term complications. This survey aimed to determine healthcare professional (HCP) and patient attitudes to BI initiation and titration. An online survey (July-August 2015) including HCPs and patients with T2DM in the USA, France and Germany. Patients were ≥18 years old and had been on BI for 6 to 36 months, or discontinued BI within the previous 12 months. Participants comprised 386 HCPs and 318 people with T2DM. While >75% of HCPs reported discussing titration at the initiation visit, only 16% to 28% of patients remembered such discussions, many (32%-42%) were unaware of the need to titrate BI, and only 28% to 39% recalled mention of the time needed to reach glycaemic goals. Most HCPs and patients agreed that more effective support tools to assist BI initiation/titration are needed; patients indicated that provision of such tools would increase confidence in self-titration. HCPs identified fear of hypoglycaemia, failure to titrate in the absence of symptoms, and low patient motivation as important titration barriers. In contrast, patients identified weight gain, the perception that titration meant worsening disease, frustration over the time to reach HbA1c goals and fear of hypoglycaemia as major factors. A disconnect exists between HCP- and patient-perceived barriers to effective BI titration. To optimize titration, strategies should be targeted to improve HCP-patient communication, and provide support and educational tools. © 2017 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.

  9. Insights into optimal basal insulin titration in type 2 diabetes: Results of a quantitative survey

    PubMed Central

    Bonnemaire, Mireille; Mical, Marie; Edelman, Steve

    2017-01-01

    Aims Basal insulin (BI) treatment initiation and dose titration in type 2 diabetes (T2DM) are often delayed. Such “clinical inertia” results in poor glycaemic control and high risk of long‐term complications. This survey aimed to determine healthcare professional (HCP) and patient attitudes to BI initiation and titration. Methods An online survey (July–August 2015) including HCPs and patients with T2DM in the USA, France and Germany. Patients were ≥18 years old and had been on BI for 6 to 36 months, or discontinued BI within the previous 12 months. Results Participants comprised 386 HCPs and 318 people with T2DM. While >75% of HCPs reported discussing titration at the initiation visit, only 16% to 28% of patients remembered such discussions, many (32%–42%) were unaware of the need to titrate BI, and only 28% to 39% recalled mention of the time needed to reach glycaemic goals. Most HCPs and patients agreed that more effective support tools to assist BI initiation/titration are needed; patients indicated that provision of such tools would increase confidence in self‐titration. HCPs identified fear of hypoglycaemia, failure to titrate in the absence of symptoms, and low patient motivation as important titration barriers. In contrast, patients identified weight gain, the perception that titration meant worsening disease, frustration over the time to reach HbA1c goals and fear of hypoglycaemia as major factors. Conclusion A disconnect exists between HCP‐ and patient‐perceived barriers to effective BI titration. To optimize titration, strategies should be targeted to improve HCP–patient communication, and provide support and educational tools. PMID:28719066

  10. Elucidation of ionic interactions in the protic ionic liquid solutions by isothermal titration calorimetry.

    PubMed

    Rai, Gitanjali; Kumar, Anil

    2014-04-17

    The strong hydrogen-bonded network noted in protic ionic liquids (PILs) may lead to stronger interactions of the ionic entities of PILs with solvents (water, methanol, ethylene glycol, dimethylsulfoxide (DMSO), N,N'-dimethylformamide (DMF)) as compared with those of aprotic ionic liquids (APILs). The PILs used in this work are 1-methylimidazolium tetrafluoroborate, 2-methylpyridinium tetrafluoroborate, and N-methylpyrrolodinium tetrafluoroborate in comparison to 1-butyl-3-methylimidazolium tetrafluoroborate, which is classified as an APIL. In this work, the excess partial molar enthalpy, H(E)IL obtained from isothermal calorimetric titrations at 298.15 K is used to probe the nature of interactions of the PIL cations with solvent molecules against those present in APIL-solvent systems. This work also reports interesting flip-flopping in the thermal behavior of these PIL-solvent systems depending upon the structure of the cationic ring of a PIL. In some cases, these flip-flops are the specific fingerprints for specific PILs in a common solvent environment. The excess partial molar enthalpy at infinite dilution, H(E,∞)IL, of these PILs bears a critical dependence on the solvent properties. An analysis of relative apparent molar enthalpies, ϕL, of the PIL solutions by the ion interaction model of Pitzer yields important information on ionic interactions of these systems.

  11. Kinetics of bacterial potentiometric titrations: the effect of equilibration time on buffering capacity of Pantoea agglomerans suspensions.

    PubMed

    Kapetas, Leon; Ngwenya, Bryne T; Macdonald, Alan M; Elphick, Stephen C

    2011-07-15

    Several recent studies have made use of continuous acid-base titration data to describe the surface chemistry of bacterial cells as a basis for accurately modelling metal adsorption to bacteria and other biomaterials of potential industrial importance. These studies do not share a common protocol; rather they titrate in different pH ranges and they use different stability criteria to define equilibration time during titration. In the present study we investigate the kinetics of bacterial titrations and test the effect they have on the derivation of functional group concentrations and acidity constants. We titrated suspensions of Pantoea agglomerans by varying the equilibration time between successive titrant additions until stability of 0.1 or 0.001 mV s(-1) was attained. We show that under longer equilibration times, titration results are less reproducible and suspensions exhibit marginally higher buffering. Fluorescence images suggest that cell lysis is not responsible for these effects. Rather, high DOC values and titration reversibility hysterisis after long equilibration times suggest that variability in buffering is due to the presence of bacterial exudates, as demonstrated by titrating supernatants separated from suspensions of different equilibration times. It is recommended that an optimal equilibration time is always determined with variable stability control and preliminary reversibility titration experiments. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Rapid Clozapine Titration in Patients with Treatment Refractory Schizophrenia.

    PubMed

    Poyraz, Cana Aksoy; Özdemir, Armağan; Sağlam, Nazife Gamze Usta; Turan, Şenol; Poyraz, Burç Çağrı; Tomruk, Nesrin; Duran, Alaattin

    2016-06-01

    The aim of this study is to evaluate the safety and effectiveness of rapid clozapine titration in patients with schizophrenia in hospital settings. We conducted a retrospective two-center cohort study to compare the safety and effectiveness of clozapine with different titration rates in treatment-refractory patients with schizophrenia. In the first center, clozapine was started at 25-50 mg followed by 50-100 mg as needed every 6 h on day 1, followed by increases of 50-100 mg/day. In the second center, titration was slower; clozapine initiated with 12.5-50 mg on day 1 followed by increases of 25-50 mg/day. The number of days between starting of clozapine until discharge was shorter in the rapid titration group (22.4 ± 8.72 vs 27.0 ± 10.5, p = 0.1). Number of days of total hospital stay were significantly shorter in the rapid titration group (29.6 ± 10.6 vs 41.2 ± 14.8, p = 0.002). Hypotension was more common in the rapid titration group and one patient had suspected myocarditis. Rapid clozapine titration appeared safe and effective. The length of stay following initiation of clozapine was shorter in the rapid-titration group, although this was not statistically significant. However starting clozapine earlier together with rapid titration has significantly shortened the length of hospital stay in patients with treatment refractory schizophrenia.

  13. Safety and tolerability of different titration rates of retigabine (ezogabine) in patients with partial-onset seizures.

    PubMed

    Biton, Victor; Gil-Nagel, Antonio; Brodie, Martin J; Derossett, Sarah E; Nohria, Virinder

    2013-11-01

    Retigabine (RTG; international nonproprietary name)/ezogabine (EZG; US adopted name) is an antiepileptic drug (AED) that prolongs neuronal voltage-gated potassium-channel KCNQ2-5 (Kv 7.2-7.5) opening. This double-blind study evaluated different RTG/EZG dose-titration rates. Patients (N=73) with partial-onset seizures receiving concomitant AEDs were randomized to one of three titration groups, all of which were initiated at RTG/EZG 300mg/day divided into three equal doses. Fast-, medium-, and slow-titration groups received dose increments of 150mg/day every 2, 4, and 7 days, respectively, achieving the target dose of 1200mg/day after 13, 25, and 43 days, respectively. Safety assessments were performed throughout. Discontinuation rates due to treatment-emergent adverse events (TEAEs) were numerically higher in the fast- (10/23) and medium- (7/22) titration groups than in the slow-titration group (3/23) but statistical significance was achieved only for the high-titration group compared with the low-titration group (p=0.024). Stratified analysis, with concomitant AEDs divided into enzyme inducers (carbamazepine, phenytoin, oxcarbazepine) or noninducers, showed that the risk of discontinuation due primarily to TEAEs was significantly higher in the fast- (p=0.010) but not in the medium-titration group (p=0.078) when compared with the slow-titration group. Overall, the slow-titration rate appeared to be best tolerated and was used in further efficacy and safety studies with RTG/EZG. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Potassium Ferricyanide Titration..., App. A Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium... buffered sulfide solution is titrated with standard potassium ferricyanide solution in the presence of a...

  15. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Potassium Ferricyanide Titration..., App. A Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium... buffered sulfide solution is titrated with standard potassium ferricyanide solution in the presence of a...

  16. Scopolamine Effects Under a Titrating-Delayed-Nonmatching-to-Position Procedure

    ERIC Educational Resources Information Center

    Porritt, M.; Poling, A.

    2008-01-01

    In a study of working memory, the performance of rats under titrating-delayed-nonmatching- to-position (TDNMTP) procedures was examined. Overall accuracy and the number of trials completed were inversely related to titration value, whereas the highest delay attained was directly related to titration value. When given intraperitoneally,…

  17. Titration Curves: Fact and Fiction.

    ERIC Educational Resources Information Center

    Chamberlain, John

    1997-01-01

    Discusses ways in which datalogging equipment can enable titration curves to be measured accurately and how computing power can be used to predict the shape of curves. Highlights include sources of error, use of spreadsheets to generate titration curves, titration of a weak acid with a strong alkali, dibasic acids, weak acid and weak base, and…

  18. Simple and Automated Coulometric Titration of Acid Using Nonisolated Electrodes

    ERIC Educational Resources Information Center

    Kuntzleman, Thomas S.; Kenney, Joshua B.; Hasbrouck, Scott; Collins, Michael J.; Amend, John R.

    2011-01-01

    Coulometric titrations involve the quantification of analyte by measurements of current and time. In most coulometric titrations, the anode and cathode are placed in isolated cells that are connected by a salt bridge. By contrast, the experiments described here involve coulometric titrations (of acidic protons in solution) using a silver anode and…

  19. Natural monocrystalline pyrite as a sensor in non-aqueous solution Part I: Potentiometric titration of weak acids in, N,N-dimethylformamide, methylpyrrolidone and pyridine.

    PubMed

    Mihajlović, Lj V; Mihajlović, R P; Antonijević, M M; Vukanović, B V

    2004-11-15

    The possibility of applying natural monocrystaline pyrite as a sensor for the potentiometric titration of weak acids in N,N-dimethylformamide, methylpyrrolidone and pyridine was investigated. The potential of this electrode in N,N-dimethylformamide, methylpyrrolidone and pyridine exhibits a sub-Nernst dependence. In N,N-dimethylformamide the slope (mV/pH) is 39.0 and in methylpyrrolidone it is 45.0. The potential jumps at the titration end-point obtained in the titration of weak acids are higher than those obtained by the application of a glass electrode as the indicator electrode The potential in the course of the titration and at the titration end-point (TEP) are rapidly established. Sodium methylate, potassium hydroxide and tetrabutylammonium hydroxide (TBAH) proved to be very suitable titrating agents for these titrations. The results obtained in the determination of the investigated weak acids deviate by 0.1-0.35% with respect to those obtained by using a glass electrode as the indicator electrode.

  20. Potentiometric titration of metal ions in ethanol.

    PubMed

    Gibson, Graham T T; Mohamed, Mark F; Neverov, Alexei A; Brown, R S

    2006-09-18

    The potentiometric titrations of Zn2+, Cu2+ and 12 Ln3+ metal ions were obtained in ethanol to determine the titration constants (defined as the at which the [-OEt]/[Mx+]t ratios are 0.5, 1.5, and 2.5) and in two cases (La3+ and Zn2+) a complete speciation diagram. Several simple monobasic acids and aminium ions were also titrated to test the validity of experimental titration measurements and to establish new constants in this medium that will be useful for the preparation of buffers and standard solutions. The dependence of the titration constants on the concentration and type of metal ion and specific counterion effects is discussed. In selected cases, the titration profiles were analyzed using a commercially available fitting program to obtain information about the species present in solution, including La3+ for which a dimer model is proposed. The fitting provides the microscopic values for deprotonation of one to four metal-bound ethanol molecules. Kinetics for the La3+-catalyzed ethanolysis of paraoxon as a function of are presented and analyzed in terms of La3+ speciation as determined by the analysis of potentiometric titration curves. The stability constants for the formation of Zn2+ and Cu2+ complexes with 1,5,9-triazacyclododecane as determined by potentiometric titration are presented.

  1. Rapid Inpatient Titration of Intravenous Treprostinil for Pulmonary Arterial Hypertension: Safe and Tolerable.

    PubMed

    El-Kersh, Karim; Ruf, Kathryn M; Smith, J Shaun

    There is no standard protocol for intravenous treprostinil dose escalation. In most cases, slow up-titration is performed in the outpatient setting. However, rapid up-titration in an inpatient setting is an alternative that provides opportunity for aggressive treatment of common side effects experienced during dose escalation. In this study, we describe our experience with inpatient rapid up-titration of intravenous treprostinil. This was a single-center, retrospective study in which we reviewed the data of subjects with pulmonary arterial hypertension treated at our center who underwent inpatient rapid up-titration of intravenous treprostinil. Our treprostinil dose escalation protocol included initiation at 2 ng·kg·min with subsequent up-titration by 1 ng·kg·min every 6 to 8 hours as tolerated by side effects. A total of 16 subjects were identified. Thirteen subjects were treprostinil naive (naive group), and 3 subjects were receiving subcutaneous treprostinil but were hospitalized for further intravenous up-titration of treprostinil dose (nonnaive group). In the naive group, the median maximum dose achieved was 20 ng·kg·min with an interquartile range (IQR) of 20-23 ng·kg·min. The median up-titration interval was 6 days (IQR: 4-9). In the nonnaive group, the median maximum dose achieved was 20 ng·kg·min (range: 17-30). The median up-titration interval was 8.5 days (range: 1.5-11). Overall, the median maximum dose achieved was 20 ng·kg·min (IQR: 20-23.5), and the median up-titration interval was 6 days (IQR: 4.6-9.25), with no reported significant adverse hemodynamic events. In patients with pulmonary arterial hypertension, rapid inpatient titration of intravenous treprostinil is safe and tolerable.

  2. Comparison of VFA titration procedures used for monitoring the biogas process.

    PubMed

    Lützhøft, Hans-Christian Holten; Boe, Kanokwan; Fang, Cheng; Angelidaki, Irini

    2014-05-01

    Titrimetric determination of volatile fatty acids (VFAs) contents is a common way to monitor a biogas process. However, digested manure from co-digestion biogas plants has a complex matrix with high concentrations of interfering components, resulting in varying results when using different titration procedures. Currently, no standardized procedure is used and it is therefore difficult to compare the performance among plants. The aim of this study was to evaluate four titration procedures (for determination of VFA-levels of digested manure samples) and compare results with gas chromatographic (GC) analysis. Two of the procedures are commonly used in biogas plants and two are discussed in literature. The results showed that the optimal titration results were obtained when 40 mL of four times diluted digested manure was gently stirred (200 rpm). Results from samples with different VFA concentrations (1-11 g/L) showed linear correlation between titration results and GC measurements. However, determination of VFA by titration generally overestimated the VFA contents compared with GC measurements when samples had low VFA concentrations, i.e. around 1 g/L. The accuracy of titration increased when samples had high VFA concentrations, i.e. around 5 g/L. It was further found that the studied ionisable interfering components had lowest effect on titration when the sample had high VFA concentration. In contrast, bicarbonate, phosphate and lactate had significant effect on titration accuracy at low VFA concentration. An extended 5-point titration procedure with pH correction was best to handle interferences from bicarbonate, phosphate and lactate at low VFA concentrations. Contrary, the simplest titration procedure with only two pH end-points showed the highest accuracy among all titration procedures at high VFA concentrations. All in all, if the composition of the digested manure sample is not known, the procedure with only two pH end-points should be the procedure of choice, due to its simplicity and accuracy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Axitinib with or without dose titration for first-line metastatic renal-cell carcinoma: a randomised double-blind phase 2 trial.

    PubMed

    Rini, Brian I; Melichar, Bohuslav; Ueda, Takeshi; Grünwald, Viktor; Fishman, Mayer N; Arranz, José A; Bair, Angel H; Pithavala, Yazdi K; Andrews, Glen I; Pavlov, Dmitri; Kim, Sinil; Jonasch, Eric

    2013-11-01

    Population pharmacokinetic data suggest axitinib plasma exposure correlates with efficacy in metastatic renal-cell carcinoma. Axitinib dose titration might optimise exposure and improve outcomes. We prospectively assessed the efficacy and safety of axitinib dose titration in previously untreated patients with metastatic renal-cell carcinoma. In this randomised, double-blind, multicentre, phase 2 study, patients were enrolled from 49 hospitals and outpatient clinics in the Czech Republic, Germany, Japan, Russia, Spain, and USA. Patients with treatment-naive metastatic renal-cell carcinoma received axitinib 5 mg twice daily during a 4 week lead-in period. Those patients with blood pressure 150/90 mm Hg or lower, no grade 3 or 4 treatment-related toxic effects, no dose reductions, and no more than two antihypertensive drugs for 2 consecutive weeks were stratified by Eastern Cooperative Oncology Group performance status (0 vs 1), and then randomly assigned (1:1) to either masked titration with axitinib to total twice daily doses of 7 mg, and then 10 mg, if tolerated, or placebo titration. Patients who did not meet these criteria continued without titration. The primary objective was comparison of the proportion of patients achieving an objective response between randomised groups. Safety analyses were based on all patients who received at least one dose of axitinib. Between Sept 2, 2009, and Feb 28, 2011, we enrolled 213 patients, of whom 112 were randomly assigned to either the axitinib titration group (56 patients) or the placebo titration group (56 patients). 91 were not eligible for titration, and ten withdrew during the lead-in period. 30 patients (54%, 95% CI 40-67) in the axitinib titration group had an objective response, as did 19 patients (34%, 22-48]) in the placebo titration group (one-sided p=0·019). 54 (59%, 95% CI 49-70) of non-randomised patients achieved an objective response. Common grade 3 or worse, all-causality adverse events in treated patients were hypertension (ten [18%] of 56 in the axitinib titration group vs five [9%] of 56 in the placebo titration group vs 45 [49%] of 91 in the non-randomised group), diarrhoea (seven [13%] vs two [4%] vs eight [9%]), and decreased weight (four [7%] vs three [5%] vs six [7%]). One or more all-causality serious adverse events were reported in 15 (27%) patients in the axitinib titration group, 13 (23%) patients in the placebo titration group, and 35 (38%) non-randomised patients. The most common serious adverse events in all 213 patients were disease progression and dehydration (eight each [4%]), and diarrhoea, vomiting, pneumonia, and decreased appetite (four each [2%]). The greater proportion of patients in the axitinib titration group achieving an objective response supports the concept of individual axitinib dose titration in selected patients with metastatic renal-cell carcinoma. Axitinib shows clinical activity with a manageable safety profile in treatment-naive patients with this disease. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. DIFFERENTIAL THERMOMETRIC TITRATIONS AND THE DETERMINATION OF HEATS OF REACTION,

    DTIC Science & Technology

    TITRATION , THERMISTORS), (*HEAT OF REACTION, TITRATION ), SILVER COMPOUNDS, NITRATES, AMMONIA, PYRIDINES, ETHYLENEDIAMINE, AMINES, ALCOHOLS, BUTANOLS, PROPANOLS, SODIUM COMPOUNDS, HYDROXIDES, TEST METHODS

  5. Determination of carbonate carbon in geological materials by coulometric titration

    USGS Publications Warehouse

    Engleman, E.E.; Jackson, L.L.; Norton, D.R.

    1985-01-01

    A coulometric titration is used for the determination of carbonate carbon in geological materials. Carbon dioxide is evolved from the sample by the addition of 2 M perchloric acid, with heating, and is determined by automated coulometric titration. The coulometric titration showed improved speed and precision with comparable accuracy to gravimetric and gasometric techniques. ?? 1985.

  6. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    PubMed Central

    Tavčar, Eva; Turk, Erika; Kreft, Samo

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD = 4.3%), accuracy, and linearity (R 2 = 0.997). PMID:22567558

  7. Implementation of a pharmacist-managed heart failure medication titration clinic.

    PubMed

    Martinez, Amanda S; Saef, Jerold; Paszczuk, Anna; Bhatt-Chugani, Hetal

    2013-06-15

    The development, implementation, and initial results of a pharmacist-managed heart failure (HF) medication titration clinic are described. In a quality-improvement initiative at a Veterans Affairs health care system, clinical pharmacists were incorporated into the hospital system's interprofessional outpatient HF clinic. In addition, a separate pharmacist-managed HF medication titration clinic was established, in which pharmacists were granted an advanced scope of practice and prescribing privileges, enabling them to initiate and adjust medication dosages under specific protocols jointly established by cardiology and pharmacy staff. Pharmacists involved in the titration clinic tracked patients' daily body weight, vital signs, and volume status using telephone-monitoring technology and via patient interviews. A retrospective chart review comparing achievement of target doses of angiotensin-converting enzyme inhibitor (ACEI), angiotensin-receptor blocker (ARB), and β-blocker therapies in a group of patients (n = 28) whose dosage titrations were carried out by nurses or physicians prior to implementation of the pharmacist-managed HF medication titration clinic and a group of patients (n = 27) enrolled in the medication titration clinic during its first six months of operation indicated that target ACEI and ARB doses were achieved in a significantly higher percentage of pharmacist-managed titration clinic enrollees (52.9% versus 31%, p = 0.007). Patients enrolled in the pharmacist-managed HF medication titration clinic also had a significantly higher rate of attainment of optimal β-blocker doses (49% versus 24.7%, p = 0.012). Implementation of a pharmacist-managed HF medication titration clinic increased the percentage of patients achieving optimal ACEI, ARB, and β-blocker dosages.

  8. Thermometric titration of cadmium with sodium diethyldithiocarbamate, with oxidation by hydrogen peroxide as indicator reaction.

    PubMed

    Hattori, T; Yoshida, H

    1987-08-01

    A new method of end-point indication is described for thermometric titration of cadmium with sodium diethyldithiocarbamate (DDTC). It is based on the redox reaction between hydrogen peroxide added to the system before titration, and the first excess of DDTC. Amounts of cadmium in the range 10-50 mumoles are titrated within 1% error.

  9. The Acid-Base Titration of a Very Weak Acid: Boric Acid

    ERIC Educational Resources Information Center

    Celeste, M.; Azevedo, C.; Cavaleiro, Ana M. V.

    2012-01-01

    A laboratory experiment based on the titration of boric acid with strong base in the presence of d-mannitol is described. Boric acid is a very weak acid and direct titration with NaOH is not possible. An auxiliary reagent that contributes to the release of protons in a known stoichiometry facilitates the acid-base titration. Students obtain the…

  10. Tracer-monitored flow titrations.

    PubMed

    Sasaki, Milton K; Rocha, Diogo L; Rocha, Fábio R P; Zagatto, Elias A G

    2016-01-01

    The feasibility of implementing tracer-monitored titrations in a flow system is demonstrated. A dye tracer is used to estimate the instant sample and titrant volumetric fractions without the need for volume, mass or peak width measurements. The approach was applied to spectrophotometric flow titrations involving variations of sample and titrant flow-rates (i.e. triangle programmed technique) or concentration gradients established along the sample zone (i.e. flow injection system). Both strategies required simultaneous monitoring of two absorbing species, namely the titration indicator and the dye tracer. Mixing conditions were improved by placing a chamber with mechanical stirring in the analytical path aiming at to minimize diffusional effects. Unlike most of flow-based titrations, the innovation is considered as a true titration, as it does not require a calibration curve thus complying with IUPAC definition. As an application, acidity evaluation in vinegars involving titration with sodium hydroxide was selected. Phenolphthalein and brilliant blue FCF were used as indicator and dye tracer, respectively. Effects of sample volume, titrand/titrant concentrations and flow rates were investigated aiming at improved accuracy and precision. Results were reliable and in agreement with those obtained by a reference titration procedure. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Determination of quaternary ammonium compounds by potentiometric titration with an ionic surfactant electrode: single-laboratory validation.

    PubMed

    Price, Randi; Wan, Ping

    2010-01-01

    A potentiometric titration for determining the quaternary ammonium compounds (QAC) commonly found in antimicrobial products was validated by a single laboratory. Traditionally, QACs were determined by using a biphasic (chloroform and water) manual titration procedure. Because of safety considerations regarding chloroform, as well as the subjectivity of color indicator-based manual titration determinations, an automatic potentiometric titration procedure was tested with quaternary nitrogen product formulations. By using the Metrohm Titrando system coupled with an ionic surfactant electrode and an Ag/AgCl reference electrode, titrations were performed with various QAC-containing formulation products/matrixes; a standard sodium lauryl sulfate solution was used as the titrant. Results for the products tested are sufficiently reproducible and accurate for the purpose of regulatory product enforcement. The robustness of the method was measured by varying pH levels, as well as by comparing buffered versus unbuffered titration systems. A quantitation range of 1-1000 ppm quaternary nitrogen was established. Eight commercially available antimicrobial products covering a variety of matrixes were assayed; the results obtained were comparable to those obtained by the manual titration method. Recoveries of 94 to 104% were obtained for spiked samples.

  12. Comparison of the clinical outcomes between unattended home APAP and polysomnography manual titration in obstructive sleep apnea patients.

    PubMed

    Wongsritrang, Krongthong; Fueangkamloon, Sumet

    2013-09-01

    To compare the clinical outcomes and determine the difference in therapeutic pressure between Automatic positive airway pressure (APAP) and polysomnography manual titration. Fifty patients of obstructive sleep apnea (OSA), moderate to severe cases, were randomized into two groups of intervention: 95-percentile pressure derived from APAP titration and an optimal pressure derived from manual titration. Clinical outcomes were assessed before and after four weeks. The average 95-percentile pressure derived from APAP titration was 11.7 +/- 0.3 cmH2O with median mask leak 1.3 L/min. The average optimal pressure derived from manual titration was 8.2 +/- 0.3 cmH2O. Pearson correlation analysis showed weak positive correlation (r = 0.336, p = 0.017). The Epworth Sleepiness Score (ESS), Quality of life tests: PSQI (Pittsburg Sleep Quality Index), and SF-36 (Medical Outcomes Study 36-Item Short-Form Health Survey) were improved significantly in both groups, but there were no statistical significant differences between groups. An APAP titration is an effective method of pressure determination for conventional CPAP therapy and shows no difference in clinical outcomes comparing the standard titration.

  13. Charge characteristics of humic and fulvic acids: comparative analysis by colloid titration and potentiometric titration with continuous pK-distribution function model.

    PubMed

    Bratskaya, S; Golikov, A; Lutsenko, T; Nesterova, O; Dudarchik, V

    2008-09-01

    Charge characteristics of humic and fulvic acids of a different origin (inshore soils, peat, marine sediments, and soil (lysimetric) waters) were evaluated by means of two alternative methods - colloid titration and potentiometric titration. In order to elucidate possible limitations of the colloid titration as an express method of analysis of low content of humic substances we monitored changes in acid-base properties and charge densities of humic substances with soil depth, fractionation, and origin. We have shown that both factors - strength of acidic groups and molecular weight distribution in humic and fulvic acids - can affect the reliability of colloid titration. Due to deviations from 1:1 stoichiometry in interactions of humic substances with polymeric cationic titrant, the colloid titration can underestimate total acidity (charge density) of humic substances with domination of weak acidic functional groups (pK>6) and high content of the fractions with molecular weight below 1kDa.

  14. Axitinib with or without dose titration for first-line metastatic renal-cell carcinoma: a randomised double-blind phase 2 trial

    PubMed Central

    Rini, Brian I; Melichar, Bohuslav; Ueda, Takeshi; GrÜnwald, Viktor; Fishman, Mayer N; Arranz, José A; Bair, Angel H; Pithavala, Yazdi K; Andrews, Glen I; Pavlov, Dmitri; Kim, Sinil; Jonasch, Eric

    2014-01-01

    Summary Background Population pharmacokinetic data suggest axitinib plasma exposure correlates with efficacy in metastatic renal-cell carcinoma. Axitinib dose titration might optimise exposure and improve outcomes. We prospectively assessed the efficacy and safety of axitinib dose titration in previously untreated patients with metastatic renal-cell carcinoma. Methods In this randomised, double-blind, multicentre, phase 2 study, patients were enrolled from 49 hospitals and outpatient clinics in the Czech Republic, Germany, Japan, Russia, Spain, and USA. Patients with treatment-naive metastatic renal-cell carcinoma received axitinib 5 mg twice daily during a 4 week lead-in period. Those patients with blood pressure 150/90 mm Hg or lower, no grade 3 or 4 treatment-related toxic effects, no dose reductions, and no more than two antihypertensive drugs for 2 consecutive weeks were stratified by Eastern Cooperative Oncology Group performance status (0 vs 1), and then randomly assigned (1:1) to either masked titration with axitinib to total twice daily doses of 7 mg, and then 10 mg, if tolerated, or placebo titration. Patients who did not meet these criteria continued without titration. The primary objective was comparison of the proportion of patients achieving an objective response between randomised groups. Safety analyses were based on all patients who received at least one dose of axitinib. This ongoing trial is registered with ClinicalTrials.gov, number NCT00835978. Findings Between Sept 2, 2009, and Feb 28, 2011, we enrolled 213 patients, of whom 112 were randomly assigned to either the axitinib titration group (56 patients) or the placebo titration group (56 patients). 91 were not eligible for titration, and ten withdrew during the lead-in period. 30 patients (54%, 95% CI 40–67) in the axitinib titration group had an objective response, as did 19 patients (34%, 22–48]) in the placebo titration group (one-sided p=0·019). 54 (59%, 95% CI 49–70) of non-randomised patients achieved an objective response. Common grade 3 or worse, all-causality adverse events in treated patients were hypertension (ten [18%] of 56 in the axitinib titration group vs five [9%] of 56 in the placebo titration group vs 45 [49%] of 91 in the non-randomised group), diarrhoea (seven [13%] vs two [4%] vs eight [9%]), and decreased weight (four [7%] vs three [5%] vs six [7%]). One or more all-causality serious adverse events were reported in 15 (27%) patients in the axitinib titration group, 13 (23%) patients in the placebo titration group, and 35 (38%) non-randomised patients. The most common serious adverse events in all 213 patients were disease progression and dehydration (eight each [4%]), and diarrhoea, vomiting, pneumonia, and decreased appetite (four each [2%]). Interpretation The greater proportion of patients in the axitinib titration group achieving an objective response supports the concept of individual axitinib dose titration in selected patients with metastatic renal-cell carcinoma. Axitinib shows clinical activity with a manageable safety profile in treatment-naive patients with this disease. Funding Pfizer Inc. PMID:24140184

  15. Titration Techniques

    NASA Astrophysics Data System (ADS)

    Jacobsen, Jerrold J.; Houston Jetzer, Kelly; Patani, Néha; Zimmerman, John; Zweerink, Gerald

    1995-07-01

    Significant attention is paid to the proper technique for reading a meniscus. Video shows meniscus-viewing techniques for colorless and dark liquids and the consequences of not reading a meniscus at eye level. Lessons are provided on approaching the end point, focusing on end point colors produced via different commonly used indicators. The concept of a titration curve is illustrated by means of a pH meter. Carefully recorded images of the entire range of meniscus values in a buret, pipet, and graduated cylinder are included so that you can show your students, in lecture or pre-lab discussion, any meniscus and discuss how to read the buret properly. These buret meniscus values are very carefully recorded at the rate of one video frame per hundredth of a milliliter, so that an image showing any given meniscus value can be obtained. These images can be easily incorporated into a computer-based multimedia environment for testing or meniscus-reading exercises. Two of the authors have used this technique and found the exercise to be very well received by their students. Video on side two shows nearly 100 "bloopers", demonstrating both the right way and wrong ways to do tasks associated with titration. This material can be used in a variety of situations: to show students the correct way to do something; to test students by asking them "What is this person doing wrong?"; or to develop multimedia, computer-based lessons. The contents of Titration Techniques are listed below: Side 1 Titration: what it is. A simple titration; Acid-base titration animation; A brief redox titration; Redox titration animation; A complete acid-base titration. Titration techniques. Hand technique variations; Stopcock; Using a buret to measure liquid volumes; Wait before reading meniscus; Dirty and clean burets; Read meniscus at eye level (see Fig. 1); Meniscus viewing techniques--light colored liquids; Meniscus viewing techniques--dark liquids; Using a magnetic stirrer; Rough titration; Significant figures; Approaching the end point; End point colors; Titration with a pH meter; Titration curves; Colors of indicators. Meniscus values. Buret meniscus values; Pipet meniscus values; Graduated cylinder meniscus values. Side 2"Bloopers". Introducing the people; Titration animation; Inspecting the buret; Rinsing the buret with water; Preparing a solid sample; Obtaining a liquid sample; Delivering a liquid sample with a Mohr pipet; Pipetting a liquid sample with a Mohr pipet; Rinsing the Mohr pipet with sample; Using the Mohr pipet to transfer sample; Delivering a liquid sample with a volumetric pipet; Pipetting a liquid sample with a volumetric pipet; Rinsing the volumetric pipet with sample; Using the volumetric pipet to transfer sample; Obtaining the titrant; Rinsing the buret with titrant; Filling the buret with titrant; Adding the indicator; The initial reading; Beginning the titration; Delivering titrant; The final reading. Figure 3. Near the end point a single drop of titrant can cause a lasting color change.

  16. Initial Evaluation of a Titration Appliance for Temporary Treatment of Obstructive Sleep Apnea.

    PubMed

    Levendowski, Daniel J; Morgan, Todd; Westbrook, Philip

    2012-01-01

    Custom oral appliances that adjustably advance the mandible provide superior outcomes when treating patients with moderate or severe sleep apnea. Custom appliances, however, are expensive, must be fitted by a dentist, and the likelihood of successful outcomes are difficult to predict. An inexpensive trial appliance, if proven efficacious, might be used to predict custom appliance outcomes or to provide temporary therapeutic benefit. The aim of this initial study was to assess the treatment efficacy of a novel titration oral appliance with that of an optimized custom appliance. Seventeen patients, treated with a custom oral appliance for at least one year, successfully completed a three-night home sleep test. The baseline obstructive sleep apnea severity was established on Night 1 with seven patients exhibiting severe, six moderate and four mild apnea/hypopnea indexes. Patients were randomly assigned to wear their custom appliance or the titration appliance on Nights 2 and 3. Significant reductions in the mean overall and supine apnea indexes (p < 0.05), and the overall (p < 0.01) and supine (p < 0.05) apnea/hypopnea indexes were observed for both the titration and custom appliances. The proportion of patients who exhibited at least a 50% reduction in the overall apnea index and supine apnea/hypopnea were similar for the titration and custom appliance (~60%). The custom appliance reduced the overall apnea/hypopnea index by 50% in a greater proportion of the patients compared to the titration appliance (77% vs. 53%). The titration appliance significantly reduced the degree of hypoxic exposure across sleep disordered breathing events overall (p < 0.05) and supine (p < 0.01). Patients found their custom appliance was more comfortable than the titration appliance, but preferred the titration appliance to no therapy. The titration appliance may be useful in assessing oral appliance treatment efficacy. When set to 70% of maximum protrusion, the titration appliance may provide immediate, temporary therapeutic benefit.

  17. Initial Evaluation of a Titration Appliance for Temporary Treatment of Obstructive Sleep Apnea

    PubMed Central

    Levendowski, Daniel J.; Morgan, Todd; Westbrook, Philip

    2015-01-01

    Background Custom oral appliances that adjustably advance the mandible provide superior outcomes when treating patients with moderate or severe sleep apnea. Custom appliances, however, are expensive, must be fitted by a dentist, and the likelihood of successful outcomes are difficult to predict. An inexpensive trial appliance, if proven efficacious, might be used to predict custom appliance outcomes or to provide temporary therapeutic benefit. Objective The aim of this initial study was to assess the treatment efficacy of a novel titration oral appliance with that of an optimized custom appliance. Methods Seventeen patients, treated with a custom oral appliance for at least one year, successfully completed a three-night home sleep test. The baseline obstructive sleep apnea severity was established on Night 1 with seven patients exhibiting severe, six moderate and four mild apnea/hypopnea indexes. Patients were randomly assigned to wear their custom appliance or the titration appliance on Nights 2 and 3. Results Significant reductions in the mean overall and supine apnea indexes (p < 0.05), and the overall (p < 0.01) and supine (p < 0.05) apnea/hypopnea indexes were observed for both the titration and custom appliances. The proportion of patients who exhibited at least a 50% reduction in the overall apnea index and supine apnea/hypopnea were similar for the titration and custom appliance (~60%). The custom appliance reduced the overall apnea/hypopnea index by 50% in a greater proportion of the patients compared to the titration appliance (77% vs. 53%). The titration appliance significantly reduced the degree of hypoxic exposure across sleep disordered breathing events overall (p < 0.05) and supine (p < 0.01). Patients found their custom appliance was more comfortable than the titration appliance, but preferred the titration appliance to no therapy. Conclusion The titration appliance may be useful in assessing oral appliance treatment efficacy. When set to 70% of maximum protrusion, the titration appliance may provide immediate, temporary therapeutic benefit. PMID:26523244

  18. Sedation during mechanical ventilation: a trial of benzodiazepine and opiate in combination.

    PubMed

    Richman, Paul S; Baram, Daniel; Varela, Marie; Glass, Peter S

    2006-05-01

    To compare the efficacy of continuous intravenous sedation with midazolam alone vs. midazolam plus fentanyl ("co-sedation") during mechanical ventilation. A randomized, prospective, controlled trial. A ten-bed medical intensive care unit at a university hospital. Thirty patients with respiratory failure who were expected to require >48 hrs of mechanical ventilation and who were receiving a sedative regimen that did not include opiate pain control. An intravenous infusion of either midazolam alone or co-sedation was administered by a nurse-implemented protocol to achieve a target Ramsay Sedation Score set by the patient's physician. Study duration was 3 days, with a brief daily "wake-up." We recorded the number of hours/day that patients were "off-target" with their Ramsay Sedation Scores, the number of dose titrations per day, the incidence of patient-ventilator asynchrony, and the time required to achieve adequate sedation as measures of sedative efficacy. We also recorded sedative cost in U.S. dollars and adverse events including hypotension, hypoventilation, ileus, and coma. Compared with the midazolam-only group, the co-sedation group had fewer hours per day with an "off-target" Ramsay Score (4.2 +/- 2.4 and 9.1 +/- 4.9, respectively, p < .002). Fewer episodes per day of patient-ventilator asynchrony were noted in the co-sedation group compared with midazolam-only (0.4 +/- 0.1 and 1.0 +/- 0.2, respectively, p < .05). Co-sedation also showed nonsignificant trends toward a shorter time to achieve sedation, a need for fewer dose titrations per day, and a lower total sedative drug cost. There was a trend toward more episodes of ileus with co-sedation compared with midazolam-only (2 vs. 0). In mechanically ventilated patients, co-sedation with midazolam and fentanyl by constant infusion provides more reliable sedation and is easier to titrate than midazolam alone, without significant difference in the rate of adverse events.

  19. Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data.

    PubMed

    Huang, Hsin-Chia Carol; Hillman, David R; McArdle, Nigel

    2012-09-01

    To investigate the factors associated with physiologic control of obstructive sleep apnea (OSA) during automatic positive airway pressure (APAP) titration in a clinical series. To also assess the usefulness of apnea-hypopnea index (AHI) data downloaded from the APAP device (Dev AHI). Retrospective review of a consecutive series of patients with OSA who underwent APAP titration (Autoset Spirit, ResMed, Bella Vista, New South Wales, Australia ) with simultaneous polysomnographic (PSG) monitoring in the sleep laboratory. Tertiary sleep clinic. There were 190 consecutive patients with OSA referred for APAP titration. There were 58% of patients who achieved optimal or good control of OSA (titration PSG AHI < 10, or at least 50% reduction in AHI if diagnostic AHI < 15/hr) during APAP titration. The independent predictors of titration PSG AHI were a history of cardiac disease and elevated central apnea and arousal indices during the diagnostic study. Although the median and interquartile range (IQR) AHI from the device (7.0, 3.9-11.6 events/hr) was only slightly less than the PSG AHI (7.8, 3.9-14.4 events/hr, P = 0.04) during titration, case-by-case agreement between the two measures was poor (chi-square < 0.001). In a clinical sample control of OSA during APAP titration is often poor, and close clinical follow-up is particularly needed in patients with a history of cardiac disease or with high arousal or central apnea indices on the diagnostic study. Device AHI does not reliably assess control during APAP titration, and PSG assessment may be required if clinical response to treatment is poor. The findings relate to the ResMed AutoSet device and may not apply to other devices.

  20. An RCT Investigating Patient-Driven Versus Physician-Driven Titration of BIAsp 30 in Patients with Type 2 Diabetes Uncontrolled Using NPH Insulin.

    PubMed

    Chraibi, Abdelmjid; Al-Herz, Shoorook; Nguyen, Bich Dao; Soeatmadji, Djoko W; Shinde, Anil; Lakshmivenkataraman, Balasubramanian; Assaad-Khalil, Samir H

    2017-08-01

    The aim of this study was to confirm the efficacy of patient-driven titration of BIAsp 30 in terms of glycemic control, by comparing it to physician-driven titration of BIAsp 30, in patients with type 2 diabetes in North Africa, the Middle East, and Asia. A 20-week, open-label, randomized, two-armed, parallel-group, multicenter study in Egypt, Indonesia, Morocco, Saudi Arabia, and Vietnam. Patients (n = 155) with type 2 diabetes inadequately controlled using neutral protamine Hagedorn (NPH) insulin were randomized to either patient-driven or physician-driven BIAsp 30 titration. The noninferiority of patient-driven compared to physician-driven titration with respect to the reduction in HbA1c was confirmed. The estimated mean change in HbA1c from baseline to week 20 was -1.27% in the patient-driven arm and -1.04% in the physician-driven arm, with an estimated treatment difference of -0.23% (95% confidence interval: -0.54; 0.08). After 20 weeks of treatment, the proportions of patients achieving the target of HbA1c <7.5% were similar between titration arms; the proportions of patients achieving the target of ≤6.5% were also similar. Both titration algorithms were well tolerated, and hypoglycemic episode rates were similar in both arms. Patient-driven titration of BIAsp 30 can be as effective and safe as physician-driven titration in non-Western populations. Overall, the switch from NPH insulin to BIAsp 30 was well tolerated in both titration arms and led to improved glycemic control. A limitation of the study was the relatively small number of patients recruited in each country. ClinicalTrials.gov NCT01589653. Novo Nordisk A/S, Denmark.

  1. Initiation of Levodopa-Carbidopa Intestinal Gel Infusion Using Telemedicine (Video Communication System) Facilitates Efficient and Well-Accepted Home Titration in Patients with Advanced Parkinson's Disease.

    PubMed

    Willows, Thomas; Dizdar, Nil; Nyholm, Dag; Widner, Håkan; Grenholm, Peter; Schmiauke, Ursula; Urbom, Anna; Groth, Kristina; Larsson, Jörgen; Permert, Johan; Kjellander, Susanna

    2017-01-01

    Levodopa-carbidopa intestinal gel (LCIG; Duodopa®) is used for continuous infusion in advanced Parkinson's disease. To achieve optimal effect, the LCIG dose is individually titrated, traditionally conducted during hospitalization in Sweden. However, dose adjustment depends on surrounding conditions, physical activity, and emotional stress, which is why titration at home could be beneficial. Telemedicine (TM) using a video communication system offers alternative titration procedures, allowing LCIG initiation at home. Study objectives were to show the feasibility of TM for LCIG home titration, evaluate resource use, and assess patient, neurologist, and nurse satisfaction. Four clinics enrolled 15 patients to observe efficiency and feasibility of TM-based monitoring. Patient median (range) age was 67 (52-73) years and time since diagnosis was 10 (7-23) years. Median time between LCIG initiation and end of TM-assisted titration was 2.8 (2.0-13.8) days. Median time required for home titration by neurologists, nurses, and patients was (hours:minutes) 1 : 14 (0 : 29-1 : 52), 5 : 49 (2 : 46-10 : 3), and 8 : 53 (4 : 11-14 : 11), respectively. Neurologists and nurses considered this to be less time than required for hospital titration. TM allowed patients 92% free time from start to end of titration. Technical problems associated with TM contacts were rare, mostly related to digital link, and quickly resolved. Patients, neurologists, and nurses were satisfied using TM. No serious adverse events were reported; there was one device complaint (tube occlusion). In this study, TM-assisted LCIG titration at home was resource-efficient, technically feasible, well-accepted and was deemed satisfactory by patients, neurologists, and nurses.

  2. Persistent benefits of slow titration of paroxetine in a six-month follow-up.

    PubMed

    Olgiati, Paolo; Serretti, Alessandro

    2015-09-01

    Paroxetine titration may be difficult in older individuals as they are more sensitive to side effects. The current study extends to 6 months our previously published report in which paroxetine was started at 2.5 mg/day and slowly increased by 2.5 mg on alternate days (slow titration) or rapidly titrated to target dose from 10 mg/day (standard titration) in a naturalistic setting. Here, the follow-up period was extended to 26 weeks. We performed an intent-to-treat analysis of 47 subjects from the original sample (major depressive disorder and/or generalized anxiety disorder (GAD); >60 years of age). Missing evaluations were replaced by last observations carried forward. GAD was included as a stratification factor. Patients in whom paroxetine was slowly up-titrated were more likely to remit (84.0% vs 54.5%; p = 0.028) and had lower core depression (p = 0.0015) and psychic anxiety levels (p = 0.006) after 26 weeks. Dropout rate was 20% in the slow titration group compared with 77.3% in the standard titration arm (p < 0.001). Patients with GAD accounted for all significant associations. No substantial differences were reported between slow and standard titration groups in the subsample without GAD. Despite some limitations, these findings suggest that paroxetine treatment should be started at lower doses in older depressed patients and slowly up-titrated. This strategy would allow to increase antidepressant response and the likelihood of completing treatment cycle in patients with high anxiety levels and GAD comorbidity. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Optimizing Glycemic Control Through Titration of Insulin Glargine 100 U/mL: A Review of Current and Future Approaches with a Focus on Asian Populations.

    PubMed

    Deerochanawong, Chaicharn; Bajpai, Shailendra; Dwipayana, I Made Pande; Hussein, Zanariah; Mabunay, Maria Aileen; Rosales, Reynaldo; Tsai, Shih-Tzer; Tsang, Man Wo

    2017-12-01

    Various data have demonstrated inadequate glycemic control amongst Asians with type 2 diabetes mellitus (T2DM), possibly on account of suboptimal titration of basal insulin-an issue which needs to be further examined. Here we review the available global and Asia-specific data on titration of basal insulin, with a focus on the use of insulin glargine 100 U/mL (Gla-100). We also discuss clinical evidence on the efficacy and safety of titrating Gla-100, different approaches to titration, including some of the latest technological advancements, and guidance on the titration of basal insulin from international and local Asian guidelines. The authors also provide their recommendations for the initiation and titration of basal insulin for Asian populations. Discussion of the data included in this review and in relation to the authors' clinical experience with treating T2DM in Asian patients is also included. Briefly, clinical studies demonstrate the achievement of adequate glycemic control in adults with T2DM through titration of Gla-100. However, studies investigating approaches to titration, specifically in Asian populations, are lacking and need to be conducted. Given that the management of insulin therapy is a multidisciplinary team effort involving endocrinologists, primary care physicians, nurse educators, and patients, greater resources and education targeted at these groups are needed regarding the optimal titration of basal insulin. Technological advancements in the form of mobile or web-based applications for automated dose adjustment can aid different stakeholders in optimizing the dose of basal insulin, enabling a larger number of patients in Asia to reach their target glycemic goals with improved outcomes.

  4. Up-titration of allopurinol in patients with gout.

    PubMed

    Jennings, Claudine G; Mackenzie, Isla S; Flynn, Rob; Ford, Ian; Nuki, George; De Caterina, Raffaele; Riches, Philip L; Ralston, Stuart H; MacDonald, Thomas M

    2014-08-01

    European League against Rheumatism (EULAR) gout management guidelines recommend achieving a target urate level <6.0 mg/dL (<357 µmol/L). Allopurinol is the most widely used urate-lowering therapy; however, many gout patients who are prescribed allopurinol do not have urate levels optimally controlled. The objective of this analysis was to review the efficacy and tolerability of allopurinol up-titration in achieving the EULAR target levels. The Febuxostat versus Allopurinol Streamlined Trial (FAST) is an ongoing multi-centre study comparing the cardiovascular safety of febuxostat and allopurinol (target recruitment: 5706 patients). Recruited patients were already taking allopurinol and the protocol required up-titration of daily allopurinol dose, in 100 mg increments, to achieve the EULAR urate target level prior to randomisation. We reviewed pre-randomisation data from the first 400 recruited and subsequently randomised FAST patients. Of 400 patients, 144 (36%) had urate levels ≥357 µmol/L at screening and required allopurinol up-titration. Higher urate levels were significantly associated with lower allopurinol dose, male sex, increased BMI, increased alcohol intake and diuretic use. Mean fall in urate levels after a single 100-mg dose increase was 71 µmol/L. The number of up-titrations required ranged from one to five (median = 1) with 65% of patients controlled after one 100-mg up-titration. Overall, 97% of up-titrated patients achieved target urate levels with median final allopurinol dose of 300 mg daily. Side effects and complications of up-titration were minimal. Overall, 36% of FAST patients were not at target urate levels and required up-titration. Allopurinol up-titration was effective in achieving urate target levels and was generally well tolerated by patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Parametric changes in response equilibrium during an intra-cranial self stimulation (ICSS) task: can reward value be assessed independently of absolute threshold?

    PubMed

    Easterling, K W; Holtzman, S G

    1997-01-01

    Traditional ICSS methodologies have attempted to evaluate changes in the rewarding value of brain stimulation by assessing the lowest value of the stimulation that will support responding. However, orderly changes in suprathreshold indicants of hedonic magnitude such as titration point have been shown. In the present experiments, rats were trained to respond on two ICSS autotitration schedules in which every response on one lever produced stimulation of the medial forebrain bundle, and every Xth response decreased either the stimulation current or the stimulation frequency. At any time, a response on a second "reset" lever restored the stimulation current or frequency available on the stimulation lever to its starting level and operationally defined changes in "reward value". In order to study this titration point measure, two response requirements (responses/stepdown; step size) and two stimulation parameters (initial stimulation level; train duration) were systematically varied. Under both current and frequency titration schedules, data indicated that response rate and titration point remained stable over repeated trials and multiple testing days--parameters being constant. Across all conditions, compared to the frequency titration schedule, subjects responding under the current titration schedule showed significantly higher titration points and lower rates of responding. Indicating the independence of rate and titration point data, parametric manipulations did not affect titration point and rate data concurrently. Results support the conclusion that titration point is a relative measure of "reward value" that is generally independent of response rate, but that is affected by manipulations that alter the amount of stimulation available between "resets". Additional work is needed in order to determine the relationship between the magnitude of stimulation needed to maintain minimal responding and that needed to maintain response equilibrium in an autotitration task.

  6. The predictive value of drug-induced sleep endoscopy for CPAP titration in OSA patients.

    PubMed

    Lan, Ming-Chin; Hsu, Yen-Bin; Lan, Ming-Ying; Huang, Yun-Chen; Kao, Ming-Chang; Huang, Tung-Tsun; Chiu, Tsan-Jen; Yang, Mei-Chen

    2017-12-15

    The aim of this study was to identify possible upper airway obstructions causing a higher continuous positive airway pressure (CPAP) titration level, utilizing drug-induced sleep endoscopy (DISE). A total of 76 patients with obstructive sleep apnea (OSA) underwent CPAP titration and DISE. DISE findings were recorded using the VOTE classification system. Polysomnographic (PSG) data, anthropometric variables, and patterns of airway collapse during DISE were analyzed with CPAP titration levels. A significant association was found between the CPAP titration level and BMI, oxygen desaturation index (ODI), apnea-hypopnea index (AHI), and neck circumference (NC) (P < 0.001, P < 0.001, P < 0.001, and P < 0.001, respectively, by Spearman correlation). Patients with concentric collapse of the velum or lateral oropharyngeal collapse were associated with a significantly higher CPAP titration level (P < 0.001 and P = 0.043, respectively, by nonparametric Mann-Whitney U test; P < 0.001 and P = 0.004, respectively, by Spearman correlation). No significant association was found between the CPAP titration level and any other collapse at the tongue base or epiglottis. By analyzing PSG data, anthropometric variables, and DISE results with CPAP titration levels, we can better understand possible mechanisms resulting in a higher CPAP titration level. We believe that the role of DISE can be expanded as a tool to identify the possible anatomical structures that may be corrected by oral appliance therapy or surgical intervention to improve CPAP compliance.

  7. Economic benefit of back titration in the treatment of hypertension in Jos, Nigeria.

    PubMed

    Okeahialam, Basil N; Adeniyi, Michael A

    2017-01-01

    Treatment of hypertension is expensive and cost is one of the reasons for inadequate blood pressure control. Where there are no social cost cushions, the burden is borne by patients. With pervasive poverty and inadequate control, complications are unchecked. Back titration in appropriate circumstances should, therefore, translate to economic benefit. This is an attempt to compute, in economic terms, the benefit of back titration. Thirty-nine patients who entered an antihypertensive back titration program for 12 months and who had been earlier reported on, form the subject of this study. A survey of the cost of antihypertensives in pharmacy outlets in Jos, Nigeria was undertaken. Regimens of antihypertensives that patients were on at the onset and end of the 12 months of back titration were costed in Nigerian currency and compared. Back titration translated to economic benefit in all patients with a cost reduction varying from 2.3% to 100%. This reflected in reduction in mean daily cost of treatment of N107.09-N54.61. The benefit of antihypertensive back titration apart from psychological relief of lower pill burden and side effect profile is in pharmacoeconomics. This permits greater adherence and prevents morbi-mortality consequences of hypertension. In this study, back titration over 12 months translated to average cost reduction of >50%, making treatment more affordable. In appropriate circumstances, back titration of antihypertensives results in economic relief for patients. This should improve adherence, reduce morbi-mortality and is recommended for wider application.

  8. Students' integration of multiple representations in a titration experiment

    NASA Astrophysics Data System (ADS)

    Kunze, Nicole M.

    A complete understanding of a chemical concept is dependent upon a student's ability to understand the microscopic or particulate nature of the phenomenon and integrate the microscopic, symbolic, and macroscopic representations of the phenomenon. Acid-base chemistry is a general chemistry topic requiring students to understand the topics of chemical reactions, solutions, and equilibrium presented earlier in the course. In this study, twenty-five student volunteers from a second semester general chemistry course completed two interviews. The first interview was completed prior to any classroom instruction on acids and bases. The second interview took place after classroom instruction, a prelab activity consisting of a titration calculation worksheet, a titration computer simulation, or a microscopic level animation of a titration, and two microcomputer-based laboratory (MBL) titration experiments. During the interviews, participants were asked to define and describe acid-base concepts and in the second interview they also drew the microscopic representations of four stages in an acid-base titration. An analysis of the data showed that participants had integrated the three representations of an acid-base titration to varying degrees. While some participants showed complete understanding of acids, bases, titrations, and solution chemistry, other participants showed several alternative conceptions concerning strong acid and base dissociation, the formation of titration products, and the dissociation of soluble salts. Before instruction, participants' definitions of acid, base, and pH were brief and consisted of descriptive terms. After instruction, the definitions were more scientific and reflected the definitions presented during classroom instruction.

  9. Differential Binding Models for Direct and Reverse Isothermal Titration Calorimetry.

    PubMed

    Herrera, Isaac; Winnik, Mitchell A

    2016-03-10

    Isothermal titration calorimetry (ITC) is a technique to measure the stoichiometry and thermodynamics from binding experiments. Identifying an appropriate mathematical model to evaluate titration curves of receptors with multiple sites is challenging, particularly when the stoichiometry or binding mechanism is not available. In a recent theoretical study, we presented a differential binding model (DBM) to study calorimetry titrations independently of the interaction among the binding sites (Herrera, I.; Winnik, M. A. J. Phys. Chem. B 2013, 117, 8659-8672). Here, we build upon our DBM and show its practical application to evaluate calorimetry titrations of receptors with multiple sites independently of the titration direction. Specifically, we present a set of ordinary differential equations (ODEs) with the general form d[S]/dV that can be integrated numerically to calculate the equilibrium concentrations of free and bound species S at every injection step and, subsequently, to evaluate the volume-normalized heat signal (δQ(V) = δq/dV) of direct and reverse calorimetry titrations. Additionally, we identify factors that influence the shape of the titration curve and can be used to optimize the initial concentrations of titrant and analyte. We demonstrate the flexibility of our updated DBM by applying these differentials and a global regression analysis to direct and reverse calorimetric titrations of gadolinium ions with multidentate ligands of increasing denticity, namely, diglycolic acid (DGA), citric acid (CIT), and nitrilotriacetic acid (NTA), and use statistical tests to validate the stoichiometries for the metal-ligand pairs studied.

  10. Concentration determination of methyl magnesium chloride and other Grignard reagents by potentiometric titration with in-line characterization of reaction species by FTIR spectroscopy.

    PubMed

    Chen, Yadan; Wang, Tao; Helmy, Roy; Zhou, George X; LoBrutto, Rosario

    2002-07-01

    A potentiometric titration method for methyl magnesium chloride and other Grignard reagents based on the reaction with 2-butanol in THF has been developed and validated. The method employs a commercially available platinum electrode, using an electrolyte compatible with non-aqueous solvents. Well-defined titration curves were obtained, along with excellent method precision. The endpoint was precisely determined based on the first derivative of the titration curve. Different solvents such as THF, diethyl ether and methylene chloride provided similar results with regard to sharpness of the endpoint and method precision. The method was applied to a wide array of Grignard reagents including methyl magnesium bromide, ethyl magnesium chloride, propyl magnesium chloride, vinyl magnesium chloride, phenyl magnesium chloride, and benzyl magnesium chloride with similar precision and accuracy. Application of in-line FTIR was demonstrated for in situ monitoring of the titration reaction, allowing characterization of the reaction species. An authentic spectrum of the MeMgCl-THF complex was obtained using spectral subtraction and the vibrational absorbance bands were identified. FTIR also provided an alternative for detecting the titration endpoint, and the titration results so obtained, provided a cross-validation of the accuracy of the potentiometric titration.

  11. Determination of polyhexamethylene biguanide hydrochloride using photometric colloidal titration with crystal violet as a color indicator.

    PubMed

    Masadome, Takashi; Miyanishi, Takaaki; Watanabe, Keita; Ueda, Hiroshi; Hattori, Toshiaki

    2011-01-01

    A solution of polyhexamethylene biguanide hydrochloride (PHMB-HCl) was titrated with a standard solution of potassium poly(vinyl sulfate) (PVSK) using crystal violet (CV) as an photometric indicator cation. The end point was detected by a sharp absorbance change due to an abrupt decrease in the concentration of CV. A linear relationship between the concentration of PHMB-HCl and the end-point volume of the titrant existed in the concentration range from 2 to 10 × 10(-6) eq mol L(-1). Back-titration was based on adding an excess amount of PVSK to a sample solution containing CV, which was titrated with a standard solution of poly(diallyldimethylammonium chloride) (PDADMAC). The calibration curve of the PHMB-HCl concentration to the end point volume of the titrant was also linear in the concentration range from 2 to 8 × 10(-6) eq mol L(-1). Both photometric titrations were applied to the determination of PHMB-HCl in a few contact-lens detergents. Back-titration showed a clear end point, but direct titration showed an unclear end point. The results of the back-titration of PHMB-HCl were compared with the content registered in its labels. 2011 © The Japan Society for Analytical Chemistry

  12. Titration in the treatment of the more troubled patient.

    PubMed

    Winer, J A; Ornstein, E D

    2001-01-01

    This article defines and discusses a modification of technique recommended by the authors in the psychoanalytic treatment of more troubled patients--a modification they call titration. Titration is defined as a conscious decision by the analyst to increase or decrease assistance (or gratification) gradually, in order to facilitate the analytic process. The authors emphasize the complexity of decisions in treatment by focusing on the decision-making processes that titration requires. Guidelines and a case vignette are presented. The authors conclude by considering some of the politics involved in the introduction of technique modifications, the salience of the titration concept, and directions for further exploration.

  13. Process monitored spectrophotometric titration coupled with chemometrics for simultaneous determination of mixtures of weak acids.

    PubMed

    Liao, Lifu; Yang, Jing; Yuan, Jintao

    2007-05-15

    A new spectrophotometric titration method coupled with chemometrics for the simultaneous determination of mixtures of weak acids has been developed. In this method, the titrant is a mixture of sodium hydroxide and an acid-base indicator, and the indicator is used to monitor the titration process. In a process of titration, both the added volume of titrant and the solution acidity at each titration point can be obtained simultaneously from an absorption spectrum by least square algorithm, and then the concentration of each component in the mixture can be obtained from the titration curves by principal component regression. The method only needs the information of absorbance spectra to obtain the analytical results, and is free of volumetric measurements. The analyses are independent of titration end point and do not need the accurate values of dissociation constants of the indicator and the acids. The method has been applied to the simultaneous determination of the mixtures of benzoic acid and salicylic acid, and the mixtures of phenol, o-chlorophenol and p-chlorophenol with satisfactory results.

  14. Salivary protein concentration, flow rate, buffer capacity and pH estimation: A comparative study among young and elderly subjects, both normal and with gingivitis and periodontitis.

    PubMed

    Shaila, Mulki; Pai, G Prakash; Shetty, Pushparaj

    2013-01-01

    To evaluate the salivary protein concentration in gingivitis and periodontitis patients and compare the parameters like salivary total protein, salivary albumin, salivary flow rate, pH, buffer capacity and flow rate in both young and elderly patients with simple methods. One hundred and twenty subjects were grouped based on their age as young and elderly. Each group was subgrouped (20 subjects) as controls, gingivitis and periodontitis. Unstimulated whole saliva was collected from patients and flow rate was noted down during collection of the sample. Salivary protein estimation was done using the Biuret method and salivary albumin was assessed using the Bromocresol green method. pH was estimated with a pHmeter and buffering capacity was analyzed with the titration method. Student's t-test, Fisher's test (ANOVA) and Tukey HSD (ANOVA) tests were used for statistical analysis. A very highly significant rise in the salivary total protein and albumin concentration was noted in gingivitis and periodontitis subjects of both young and elderly. An overall decrease in salivary flow rate was observed among the elderly, and also the salivary flow rate of women was significantly lower than that of men. Significant associations between salivary total protein and albumin in gingivitis and periodontitis were found with simple biochemical tests. A decrease in salivary flow rate among elderly and among women was noted.

  15. An Olfactory Indicator for Acid-Base Titrations.

    ERIC Educational Resources Information Center

    Flair, Mark N.; Setzer, William N.

    1990-01-01

    The use of an olfactory acid-base indicator in titrations for visually impaired students is discussed. Potential olfactory indicators include eugenol, thymol, vanillin, and thiophenol. Titrations performed with each indicator with eugenol proved to be successful. (KR)

  16. On-Board Monitoring of Engine Oil

    DTIC Science & Technology

    2011-04-01

    Viscosity of Transparent and Opaque Liquids at 40°C Infracal Soot Meter Karl Fischer Titration ASTM D 664 Standard Test Method for Acid Number of... methods involve potentiometric and colorimetric titrations, respectively. For both tests, a titration solvent is prepared and added to the oil. The...ASTM D 2896 and ASTM D 4739 [17]. Both methods involve potentiometric titrations. ASTM D 2896 uses a stronger acid and more polar solvent than ASTM D

  17. Integration and global analysis of isothermal titration calorimetry data for studying macromolecular interactions.

    PubMed

    Brautigam, Chad A; Zhao, Huaying; Vargas, Carolyn; Keller, Sandro; Schuck, Peter

    2016-05-01

    Isothermal titration calorimetry (ITC) is a powerful and widely used method to measure the energetics of macromolecular interactions by recording a thermogram of differential heating power during a titration. However, traditional ITC analysis is limited by stochastic thermogram noise and by the limited information content of a single titration experiment. Here we present a protocol for bias-free thermogram integration based on automated shape analysis of the injection peaks, followed by combination of isotherms from different calorimetric titration experiments into a global analysis, statistical analysis of binding parameters and graphical presentation of the results. This is performed using the integrated public-domain software packages NITPIC, SEDPHAT and GUSSI. The recently developed low-noise thermogram integration approach and global analysis allow for more precise parameter estimates and more reliable quantification of multisite and multicomponent cooperative and competitive interactions. Titration experiments typically take 1-2.5 h each, and global analysis usually takes 10-20 min.

  18. Efficacy and Tolerability of Two Different Kinds of Titration of Paroxetine Hydrocloride Solution: an Observational Study.

    PubMed

    Ielmini, Marta; Poloni, Nicola; Caselli, Ivano; Bianchi, Lucia; Diurni, Marcello; Vender, Simone; Callegari, Camilla

    2018-03-13

    Depressive disorders are expected to be the second highest cause of morbidity in the world until few years. Moreover, patients with depression frequently show many side effects and low compliance to therapy. To find a more tolerated and more efficacy therapy is a growing need. This observational study investigates the efficacy, safety and tolerability of paroxetine hydrochloride comparing slow versus standard titration in a population affected by Depressive Disoders (according to DSM 5). 186 outpatients were assessed throught the following scales: Hamilton Depression Rating Scale (HDRS) for depression and World Health Organization Quality of Life Scale Bref for the perceived quality of life (WHOQOL BREF). Treatment-emerged Adverse Events (TEAEs) were recorded throught self-reports. Statystical analysys was performed by GraphPad Prism Version 5.1. The efficacy of paroxetine was confirmed in both titrations by the number of clinical remitters (HDRS ≤ 7 at 12 weeks for 53% of the standard titration group and 58% of the slow titration group), without differences. About safety and tolerability there were more frequent TEAEs among the standard titration group (p < 0.01). Comparing WHOQOL BREF between the two groups at the recruitment and at the twelth week emerged a statistically significant difference (p = 0.003), with highest scores reached in slow titration group. Although the short observation period is an evident limit, this study is consistent to the literature about the efficacy of both titrations of paroxetine to improve depression and shows promising results about the increased tolerability of paroxetine slow titration.

  19. Titration Calorimetry Standards and the Precision of Isothermal Titration Calorimetry Data

    PubMed Central

    Baranauskienė, Lina; Petrikaitė, Vilma; Matulienė, Jurgita; Matulis, Daumantas

    2009-01-01

    Current Isothermal Titration Calorimetry (ITC) data in the literature have relatively high errors in the measured enthalpies of protein-ligand binding reactions. There is a need for universal validation standards for titration calorimeters. Several inorganic salt co-precipitation and buffer protonation reactions have been suggested as possible enthalpy standards. The performances of several commercial calorimeters, including the VP-ITC, ITC200, and Nano ITC-III, were validated using these suggested standard reactions. PMID:19582227

  20. Benefit of slow titration of paroxetine to treat depression in the elderly.

    PubMed

    Olgiati, Paolo; Bajo, Emanuele; Serretti, Alessandro

    2014-11-01

    Paroxetine is commonly used to treat depression in the elderly; however, titration issues have been raised. Rapid titration may lead to increased anxiety and early dropout. The aim of this cost-utility analysis was to compare the potential benefit of standard (10 mg the first day) versus slow titration (2.5 mg gradually increased). Clinical analysis was based on a naturalistic trial integrated with a decision-analytic model representing second treatments for those who initially did not respond and for dropout cases. Treatment setting was a public outpatient center for mental disorders in Italy. Service use data were estimated from best practice guidelines, whereas costs (Euros; 2012) were retrieved from Italian official sources. Slow titration approach produced 0.031 more quality-adjusted life years (remission rate: 57% vs 44% in standard titration group) at an incremental cost of €5.53 (generic paroxetine) and €54.54 (brand paroxetine syrup). Incremental cost-effectiveness ratio (ICER) values were €159 and €1768, respectively, in favor of slow titration approach. Cost-effectiveness threshold, defined as ICER < 1 GDP per capita according to World Health Organization criteria, is about €25 000 in Italy. Our results are consistent with a superiority of slow titration of paroxetine in older depressed patients. However, these findings, in part based on simulated data, need to be replicated in clinical trials. Copyright © 2014 John Wiley & Sons, Ltd.

  1. Control of OSA During Automatic Positive Airway Pressure Titration in a Clinical Case Series: Predictors and Accuracy of Device Download Data

    PubMed Central

    Huang, Hsin-Chia Carol; Hillman, David R.; McArdle, Nigel

    2012-01-01

    Study Objectives: To investigate the factors associated with physiologic control of obstructive sleep apnea (OSA) during automatic positive airway pressure (APAP) titration in a clinical series. To also assess the usefulness of apnea-hypopnea index (AHI) data downloaded from the APAP device (Dev AHI). Design: Retrospective review of a consecutive series of patients with OSA who underwent APAP titration (Autoset Spirit, ResMed, Bella Vista, New South Wales, Australia ) with simultaneous polysomnographic (PSG) monitoring in the sleep laboratory. Setting: Tertiary sleep clinic. Participants: There were 190 consecutive patients with OSA referred for APAP titration. Measurements and Results: There were 58% of patients who achieved optimal or good control of OSA (titration PSG AHI < 10, or at least 50% reduction in AHI if diagnostic AHI < 15/hr) during APAP titration. The independent predictors of titration PSG AHI were a history of cardiac disease and elevated central apnea and arousal indices during the diagnostic study. Although the median and interquartile range (IQR) AHI from the device (7.0, 3.9-11.6 events/hr) was only slightly less than the PSG AHI (7.8, 3.9-14.4 events/hr, P = 0.04) during titration, case-by-case agreement between the two measures was poor (chi-square < 0.001). Conclusion: In a clinical sample control of OSA during APAP titration is often poor, and close clinical follow-up is particularly needed in patients with a history of cardiac disease or with high arousal or central apnea indices on the diagnostic study. Device AHI does not reliably assess control during APAP titration, and PSG assessment may be required if clinical response to treatment is poor. The findings relate to the ResMed AutoSet device and may not apply to other devices. Citation: Huang HCC; Hillman DR; McArdle N. Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data. SLEEP 2012;35(9):1277–1283. PMID:22942506

  2. Initiation of Levodopa-Carbidopa Intestinal Gel Infusion Using Telemedicine (Video Communication System) Facilitates Efficient and Well-Accepted Home Titration in Patients with Advanced Parkinson’s Disease

    PubMed Central

    Willows, Thomas; Dizdar, Nil; Nyholm, Dag; Widner, Håkan; Grenholm, Peter; Schmiauke, Ursula; Urbom, Anna; Groth, Kristina; Larsson, Jörgen; Permert, Johan; Kjellander, Susanna

    2017-01-01

    Background: Levodopa-carbidopa intestinal gel (LCIG; Duodopa®) is used for continuous infusion in advanced Parkinson’s disease. To achieve optimal effect, the LCIG dose is individually titrated, traditionally conducted during hospitalization in Sweden. However, dose adjustment depends on surrounding conditions, physical activity, and emotional stress, which is why titration at home could be beneficial. Telemedicine (TM) using a video communication system offers alternative titration procedures, allowing LCIG initiation at home. Objective: Study objectives were to show the feasibility of TM for LCIG home titration, evaluate resource use, and assess patient, neurologist, and nurse satisfaction. Methods: Four clinics enrolled 15 patients to observe efficiency and feasibility of TM-based monitoring. Results: Patient median (range) age was 67 (52–73) years and time since diagnosis was 10 (7–23) years. Median time between LCIG initiation and end of TM-assisted titration was 2.8 (2.0–13.8) days. Median time required for home titration by neurologists, nurses, and patients was (hours:minutes) 1 : 14 (0 : 29–1 : 52), 5 : 49 (2 : 46–10 : 3), and 8 : 53 (4 : 11–14 : 11), respectively. Neurologists and nurses considered this to be less time than required for hospital titration. TM allowed patients 92% free time from start to end of titration. Technical problems associated with TM contacts were rare, mostly related to digital link, and quickly resolved. Patients, neurologists, and nurses were satisfied using TM. No serious adverse events were reported; there was one device complaint (tube occlusion). Conclusions: In this study, TM-assisted LCIG titration at home was resource-efficient, technically feasible, well-accepted and was deemed satisfactory by patients, neurologists, and nurses. PMID:28984615

  3. [Determination of peracetic acid and hydrogen peroxide in a preparation].

    PubMed

    Bodiroga, Milanka; Ognjanović, Jasminka

    2002-01-01

    Iodometric and permanganometric titrations were used for determination of peracetic acid and hydrogen peroxide (H2O2) in the mixture. Two procedures were described and compared. Titrations could be done in only one vessel, in the same reaction mixture, when iodometric titration of peracetic acid was continued after the permanganometric titration of H2O2, (procedure A). Peracetic acid and H2O2, as oxidizing agents, reacted with potassium iodide in an acid medium, evolving iodine. This reaction was used for the quantitative iodometric determination of total peroxide in procedure B. H2O2 reacted with potassium permanganate in acid medium, but peracetic acid did not react under the same conditions. That made possible the selective permanganometric determination of H2O2 in the presence of peracetic acid. The procedure B was performed in two titration vessels (KV = 3.4% for peracetic acid, 0.6% for H2O2). The procedure A for iodometric determination of peracetic acid in one titration vessel after permanganometric titration of H2O2 was recommended (KV = 2.5% for peracetic acid, 0.45% for H2O2).

  4. A model for oxygen conservation associated with titration during pediatric oxygen therapy.

    PubMed

    Wu, Grace; Wollen, Alec; Himley, Stephen; Austin, Glenn; Delarosa, Jaclyn; Izadnegahdar, Rasa; Ginsburg, Amy Sarah; Zehrung, Darin

    2017-01-01

    Continuous oxygen treatment is essential for managing children with hypoxemia, but access to oxygen in low-resource countries remains problematic. Given the high burden of pneumonia in these countries and the fact that flow can be gradually reduced as therapy progresses, oxygen conservation through routine titration warrants exploration. To determine the amount of oxygen saved via titration during oxygen therapy for children with hypoxemic pneumonia. Based on published clinical data, we developed a model of oxygen flow rates needed to manage hypoxemia, assuming recommended flow rate at start of therapy, and comparing total oxygen used with routine titration every 3 minutes or once every 24 hours versus no titration. Titration every 3 minutes or every 24 hours provided oxygen savings estimated at 11.7% ± 5.1% and 8.1% ± 5.1% (average ± standard error of the mean, n = 3), respectively. For every 100 patients, 44 or 30 kiloliters would be saved-equivalent to 733 or 500 hours at 1 liter per minute. Ongoing titration can conserve oxygen, even performed once-daily. While clinical validation is necessary, these findings could provide incentive for the routine use of pulse oximeters for patient management, as well as further development of automated systems.

  5. Home blood pressure monitoring and self-titration of antihypertensive medications: Proposed patient selection criteria.

    PubMed

    Hill, James R

    2016-05-01

    Recent studies have demonstrated that home blood pressure monitoring (HBPM), coupled with self-titration of medications is a viable intervention to control hypertension. There are currently no established criteria to evaluate patients for inclusion in such a program. The purpose of this discussion is to propose criteria for determining if a patient is appropriate to participate in a program of HBPM and self-titration. Inclusion criteria for two self-titration trials were examined, and additional factors in clinical practice were identified and discussed. Additional selection criteria were proposed to support the decision to enroll a patient in an antihypertensive self-titration program. Inclusion criteria from self-titration trials provide a reasonable starting point for choosing appropriate patients in clinical practice, but additional research is necessary. Adaptation of these criteria and consideration of the identified factors can be used to develop decision support instruments. Such instruments should be evaluated for effectiveness and reliability prior to use in clinical practice. HBPM combined with self-titration is an effective patient-centered approach for hypertension management. Decision support instruments to determine appropriate patients are necessary for safe and effective use in clinical practice. ©2015 American Association of Nurse Practitioners.

  6. Thermometric titrations of amines with nitrosyl perchlorate in acetonitrile solvent.

    PubMed

    Gündüz, T; Kiliç, E; Cakirer, O

    1996-05-01

    Thirteen aliphatic and four aromatic amines, namely diethylamine, triethylamine, n-propylamine, di-n-propylamine, tri-n-butylamine, isopropylamine, di-isopropylamine, n-butylamine, di-n-butylamine, tri-n-butylamine, isobutylamine, sec-butylamine, tert-butylamine, aniline, N,N-dimethylaniline, 2-nitroaniline and 4-nitroaniline were titrated thermometrically with nitrosyl perchlorate in acetonitrile solvent. All the aliphatic amines gave very well-shaped thermometric titration curves. The calculated recovery values of the amines were very good. In comparison, the aromatic amines, aniline and N,N-dimethylaniline gave rather well-shaped titration curves, but the recovery values were fairly low. 2-Nitro- and 4-nitro anilines gave no thermometric response at all. The heats of reaction of the amines with nitrosyl perchlorate are rather high. However, the average heat of reaction of the aromatic amines is approximately two-thirds that of the average heat of the aliphatic amines. To support this method all the amines were also titrated potentiometrically and very similar results to those obtained with the thermometric method are seen. The nitrosyl ion is a Lewis acid, strong enough to titrate quantitatively aliphatic amines in acetonitrile solvent, but not strong enough to titrate aromatic amines at the required level in the same solvent.

  7. Assessment of residual active chlorine in sodium hypochlorite solutions after dissolution of porcine incisor pulpal tissue.

    PubMed

    Clarkson, R M; Smith, T K; Kidd, B A; Evans, G E; Moule, A J

    2013-12-01

    In previous studies, surfactant-containing Hypochlor brands of sodium hypochlorite showed better tissue solubilizing abilities than Milton; differences not explained by original active chlorine content or presence of surfactant. It was postulated that exhaustion of active chlorine content could explain differences. This study aimed to assess whether Milton's poorer performance was due to exhaustion of active chlorine. Parallel experiments assessed the influence of titration methods, and the presence of chlorates, on active chlorine measurements. Time required to dissolve one or groups of 10 samples of porcine incisor pulp samples in Milton was determined. Residual active chlorine was assessed by thermometric titration. Iodometric and thermometric titration was carried out on samples of Milton. Chlorate content was also measured. Dissolution of single and 10 pulp samples caused a mean loss of 1% and 3% respectively of active chlorine, not being proportional to tissue dissolved. Thermometric ammonium ion titration resulted in 10% lower values than iodometric titration. Chlorate accounted for much of this difference. Depletion of active chlorine is not the reason for differences in tissue dissolving capabilities of Milton. Thermometric ammonium ion titration gives more accurate measurement of active chlorine content than iodometric titration. © 2013 Australian Dental Association.

  8. Spectrophotometric Titration of a Mixture of Calcium and Magnesium.

    ERIC Educational Resources Information Center

    Fulton, Robert; And Others

    1986-01-01

    Describes a spectrophotometric titration experiment which uses a manual titration spectrophotometer and manually operated buret, rather than special instrumentation. Identifies the equipment, materials, and procedures needed for the completion of the experiment. Recommends the use of this experiment in introductory quantitative analysis…

  9. pH Static Titration: A Quasistatic Approach

    ERIC Educational Resources Information Center

    Michalowski, Tadeusz; Toporek, Marcin; Rymanowski, Maciej

    2007-01-01

    The pH-static titration is applicable to those systems where at least two types of reactions occur in comparable intensities. The commonalities in titrimetric procedure realized according to pH-static titration, irrespective of the kind of chemical processes occurring are discussed.

  10. The Potentiometric Titration of Filtrates from the Bachmann Process

    DTIC Science & Technology

    1942-06-23

    SCIENTIFIC RESEARCH AND DEVELOP11ENT The Potentiometric Titration of Filtrates from the Bachmann Process (OD-12) by F. C. Whitmore OSRD No. 654... Potentiometric Titration of Synthetic Mixtures. A? Nitric Acid-Acetic Acid. A sample of 60 ml. glacial acetic acid war diluted to 200 ml. with distilled...i4flinflr?fj3 TADLE 1 CO) |S?lDBnTl» POTENTIOMETRIC TITRATION OF SYNTHETIC t’.IXTURES WITH CONCENTRATED AJKDNIUM HYDROXIDE A; unonium HNO-j- AcOfi Ky

  11. Quantitative Determination of NTA and Other Chelating Agents in Detergents by Potentiometric Titration with Copper Ion Selective Electrode.

    PubMed

    Ito, Sana; Morita, Masaki

    2016-01-01

    Quantitative analysis of nitrilotriacetate (NTA) in detergents by titration with Cu 2+ solution using a copper ion selective electrode was achieved. This method tolerates a wide range of pH and ingredients in detergents. In addition to NTA, other chelating agents, having relatively lower stability constants toward Cu 2+ , were also qualified with sufficient accuracy by this analytical method for model detergent formulations. The titration process was automated by automatic titrating systems available commercially.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pauli, Adam T; Robertson, Raymond E; Branthaver, Jan F

    A system for determining parameters and compatibility of a substance such as an asphalt or other petroleum substance uses titration to highly accurately determine one or more flocculation occurrences and is especially applicable to the determination or use of Heithaus parameters and optimal mixing of various asphalt stocks. In a preferred embodiment, automated titration in an oxygen gas exclusive system and further using spectrophotometric analysis (2-8) of solution turbidity is presented. A reversible titration technique enabling in-situ titration measurement of various solution concentrations is also presented.

  13. A Microscale Spectrophotometric Determination of Water Hardness

    NASA Astrophysics Data System (ADS)

    Gordon, James S.

    2001-08-01

    A spectrophotometric titration was performed to determine water hardness. The titration incorporated the traditional titration method employing EDTA as the titrant and calmagite as the indicator. The microscale experiment was carried out in a spectrometer cuvette and made use of a Texas Instruments (TI-83) calculator interfaced through a TI Calculator-Based Laboratory system to a Vernier colorimeter as the detector. Monitoring at 635 nm, one of the colorimeter's fixed wavelengths, was well suited for this analysis. Agreement was found with results from traditional titrations.

  14. Process for Assessing the Stability of HAN (Hydroxylamine)-Based Liquid Propellants.

    DTIC Science & Technology

    1987-07-29

    liquid propellants on the basis of HAN according to Fig. 1 can be determined directly by Fischer titration. This method requires a special unit, as the...Wasserreagenzien nach Eugen Scholz fUr die Karl - Fischer -Titration (Guidelines by Messrs. Riedel-de Haen for Titration according to the Karl Fischer ...Propellant components 2 2.2 Methods of determination 3 2.3 Acid/base titration and pK values 4 2.4 The Titroprozessor 636 8 2.5 Propellant analyses 10

  15. Value of routine investigations to predict loop diuretic down-titration success in stable heart failure.

    PubMed

    Martens, Pieter; Verbrugge, Frederik H; Boonen, Levinia; Nijst, Petra; Dupont, Matthias; Mullens, Wilfried

    2018-01-01

    Guidelines advocate down-titration of loop diuretics in chronic heart failure (CHF) when patients have no signs of volume overload. Limited data are available on the expected success rate of this practice or how routine diagnostic tests might help steering this process. Fifty ambulatory CHF-patients on stable neurohumoral blocker/diuretic therapy for at least 3months without any clinical sign of volume overload were prospectively included to undergo loop diuretic down-titration. All patients underwent a similar pre-down-titration evaluation consisting of a dyspnea scoring, physical examination, transthoracic echocardiography (diastolic function, right ventricular function, cardiac filling pressures and valvular disease), blood sample (serum creatinine, plasma NT-pro-BNP and neurohormones). Loop diuretic maintenance dose was subsequently reduced by 50% or stopped if dose was ≤40mg furosemide equivalents. Successful down-titration was defined as a persistent dose reduction after 30days without weight increase >1.5kg or new-onset symptoms of worsening heart failure. At 30-day follow-up, down-titration was successful in 62% (n=31). In 12/19 patients exhibiting down-titration failure, this occurred within the first week. Physical examination, transthoracic echocardiography and laboratory analysis had limited predictive capability to detect patients with down-titration success/failure (positive likelihood-ratios below 1.5, or area under the curve [AUC] non-statically different from AUC=0.5). Loop diuretic down-titration is feasible in a majority of stable CHF patients in which the treating clinician felt continuation of loops was unnecessary to sustain euvolemia. Importantly, routine diagnostics which suggest euvolemia, have limited diagnostic impact on the post-test probability. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Immediate effect of CPAP titration on perceived health related quality of life: a prospective observational study.

    PubMed

    Iacono Isidoro, Serena; Salvaggio, Adriana; Lo Bue, Anna; Romano, Salvatore; Marrone, Oreste; Insalaco, Giuseppe

    2016-12-01

    Perceived Health Related Quality of Life (HRQoL) is impaired in obstructive sleep apnea (OSA). This study examines changes in HRQoL aspects occurring immediately after CPAP titration. Furthermore, we analyzed variations in each gender and in patients undergoing home or laboratory-based CPAP titration pathways. Twohundredfive outpatients (151 M) (56.7 ± 10.3 years) were evaluated, before first visit and nocturnal diagnostic examination (T0), and the morning after CPAP titration (T1). Two self-reported HRQoL questionnaires were administered: Psychological General Well-Being Index (PGWBI), composed by six subscales, and 12-Item Short-Form Health Survey (SF-12), including Physical (PCS) and Mental Component Summaries (MCS). CPAP titration was performed using auto-adjusting CPAP units at patients' home or in the sleep laboratory. PGWBI scores at T1 improved compared to T0 (p < 0.0001). A similar improvement was observed in SF-12 MCS (p = 0.0011), but not in SF-12 PCS. Changes were independent from anthropometric parameters, OSA severity and excessive daytime sleepiness. Gender comparisons showed better HRQoL in males at both times. At T0, patients who received home or laboratory CPAP titration pathways did not show any differences in PGWBI and SF-12 scores. At T1, PGWBI and SF-12 MCS improved in both home and laboratory groups. This study gives evidence that first time CPAP application for titration can lead to a general increase in perceived well-being. Gender comparisons showed better perceived HRQoL with more subscales improvements in males after CPAP titration. The improvement was similar with both home and laboratory CPAP titration pathways.

  17. Effects of positive end-expiratory pressure titration and recruitment maneuver on lung inflammation and hyperinflation in experimental acid aspiration-induced lung injury.

    PubMed

    Ambrosio, Aline M; Luo, Rubin; Fantoni, Denise T; Gutierres, Claudia; Lu, Qin; Gu, Wen-Jie; Otsuki, Denise A; Malbouisson, Luiz M S; Auler, Jose O C; Rouby, Jean-Jacques

    2012-12-01

    In acute lung injury positive end-expiratory pressure (PEEP) and recruitment maneuver are proposed to optimize arterial oxygenation. The aim of the study was to evaluate the impact of such a strategy on lung histological inflammation and hyperinflation in pigs with acid aspiration-induced lung injury. Forty-seven pigs were randomly allocated in seven groups: (1) controls spontaneously breathing; (2) without lung injury, PEEP 5 cm H2O; (3) without lung injury, PEEP titration; (4) without lung injury, PEEP titration + recruitment maneuver; (5) with lung injury, PEEP 5 cm H2O; (6) with lung injury, PEEP titration; and (7) with lung injury, PEEP titration + recruitment maneuver. Acute lung injury was induced by intratracheal instillation of hydrochloric acid. PEEP titration was performed by incremental and decremental PEEP from 5 to 20 cm H2O for optimizing arterial oxygenation. Three recruitment maneuvers (pressure of 40 cm H2O maintained for 20 s) were applied to the assigned groups at each PEEP level. Proportion of lung inflammation, hemorrhage, edema, and alveolar wall disruption were recorded on each histological field. Mean alveolar area was measured in the aerated lung regions. Acid aspiration increased mean alveolar area and produced alveolar wall disruption, lung edema, alveolar hemorrhage, and lung inflammation. PEEP titration significantly improved arterial oxygenation but simultaneously increased lung inflammation in juxta-diaphragmatic lung regions. Recruitment maneuver during PEEP titration did not induce additional increase in lung inflammation and alveolar hyperinflation. In a porcine model of acid aspiration-induced lung injury, PEEP titration aimed at optimizing arterial oxygenation, substantially increased lung inflammation. Recruitment maneuvers further improved arterial oxygenation without additional effects on inflammation and hyperinflation.

  18. Impact of hypoglycemic events and HbA1c level on sulfonylurea discontinuation and down-titration.

    PubMed

    Laires, Pedro A; Tang, Jackson; Fan, Chun Po Steve; Li, Zhiyi; Qiu, Ying; Iglay, Kristy

    2017-04-01

    A retrospective cohort study using GE Centricity electronic medical records assessed the association between post-index hypoglycemia and HbA1c with discontinuation and down-titration of sulfonylureas among patients with Type 2 diabetes mellitus. Adult patients with an index prescription for a sulfonylurea and ≥12 months' continuous records pre- and post-index were eligible. Sulfonylurea discontinuation and down-titration was assessed 1-year post-index. Discontinuation occurred if the date of a prescription was >90 days from the preceding prescription plus days of supply. Down-titration occurred when a subsequent prescription was lower than the index dose. Cox regression assessed the association between post-index hypoglycemia and HbA1c with time to sulfonylurea discontinuation and down-titration, as well as other factors. 28,371 participants were included in the study; 13,459 (47.4%) were discontinuers, 717 (2.5%) were down-titraters, and 14,195 (50.0%) were continuers. 0.6% of continuers experienced hypoglycemia 1-year post-index, compared with 3.1% of down-titraters and 0.8% of discontinuers (p < 0.0001). Patients with post-index hypoglycemia had a significantly higher rate of discontinuation (hazard ratio [HR] = 1.82, 95% CI: 1.47-2.23) and down-titration (HR = 4.25, 95% CI: 1.92-8.03). Patients with higher post-index HbA1c and use of 2 nd generation sulfonylureas had an increased rate of discontinuation (HR = 1.05, 95% CI: 1.04-1.06; HR = 1.19, 95% CI: 1.14-1.24, respectively). Approximately half of participants who initiated sulfonylureas discontinued or down-titrated therapy within one year. Both post-index hypoglycemia and higher HbA1c were significant risk factors for sulfonylurea treatment change.

  19. Highly accurate nephelometric titrimetry.

    PubMed

    Zhan, Xiancheng; Li, Chengrong; Li, Zhiyi; Yang, Xiucen; Zhong, Shuguang; Yi, Tao

    2004-02-01

    A method that accurately indicates the end-point of precipitation reactions by the measurement of the relative intensity of the scattered light in the titrate is presented. A new nephelometric titrator with an internal nephelometric sensor has been devised. The work of the titrator including the sensor and change in the turbidity of the titrate and intensity of the scattered light are described. The accuracy of the nephelometric titrimetry is discussed theoretically. The titration of NaCl with AgNO(3) serves as a model. A relative error as well as deviation is within 0.2% under the experimental conditions. The applicability of the titrimetry in pharmaceutical analyses, for example, phenytoin sodium and procaine hydrochloride, is generally illustrated. Copyright 2004 Wiley-Liss, Inc. and the American Pharmacists Association

  20. Microtitration of various anions with quaternary ammonium halides using solid-state electrodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Selig, W.

    1980-01-01

    Many solid-state electrodes were found to respond as endpoint detectors in the potentiometric titration of large inorganic and organic anions with quaternary ammonium halides. The best response was obtained with the iodide and cyanide electrodes although practically any electrode can function as endpoint sensor. The titrants were hexadecylpyridinium chloride and hexadecyltrimethylammonium chloride; hexadecyltrimethylammonium bromide and Hyamine 1622 may also be used. Some inorganic anions thus titratable are perrhenate, persulfate, ferricyanide, hexafluorophosphate, and hexachloroplatinate. Examples of organic anions titratable are nitroform, tetraphenylborate, cyanotriphenylborate, picrate, long-chain sulfates and sulfonates, and some soaps. The reverse titration of quaternary ammonium halides vs dodecylsulfate ismore » also feasible. Some titrations are feasible in a partially nonaqueous medium.« less

  1. Symmetry Properties of Potentiometric Titration Curves.

    ERIC Educational Resources Information Center

    Macca, Carlo; Bombi, G. Giorgio

    1983-01-01

    Demonstrates how the symmetry properties of titration curves can be efficiently and rigorously treated by means of a simple method, assisted by the use of logarithmic diagrams. Discusses the symmetry properties of several typical titration curves, comparing the graphical approach and an explicit mathematical treatment. (Author/JM)

  2. A Tabular Approach to Titration Calculations

    ERIC Educational Resources Information Center

    Lim, Kieran F.

    2012-01-01

    Titrations are common laboratory exercises in high school and university chemistry courses, because they are easy, relatively inexpensive, and they illustrate a number of fundamental chemical principles. While students have little difficulty with calculations involving a single titration step, there is a significant leap in conceptual difficulty…

  3. LIGHT TITRATIONS

    PubMed Central

    Field, John; Baas-Becking, Lourens G. M.

    1926-01-01

    1. The usefulness of the radiomicrometer in titration work has been pointed out. The authors suggest that light titration may also be used where a reaction mixture changes its absorption in the (near) infra-red. 2. The applicability of this method to the starch-iodine reaction has been demonstrated. PMID:19872266

  4. A Closer Look at Acid-Base Olfactory Titrations

    ERIC Educational Resources Information Center

    Neppel, Kerry; Oliver-Hoyo, Maria T.; Queen, Connie; Reed, Nicole

    2005-01-01

    Olfactory titrations using raw onions and eugenol as acid-base indicators are reported. An in-depth investigation on olfactory titrations is presented to include requirements for potential olfactory indicators and protocols for using garlic, onions, and vanillin as acid-base olfactory indicators are tested.

  5. Switching From Age-Based Stimulus Dosing to Dose Titration Protocols in Electroconvulsive Therapy: Empirical Evidence for Better Patient Outcomes With Lower Peak and Cumulative Energy Doses.

    PubMed

    O'Neill-Kerr, Alex; Yassin, Anhar; Rogers, Stephen; Cornish, Janie

    2017-09-01

    The aim of this study was to test the proposition that adoption of a dose titration protocol may be associated with better patient outcomes, at lower treatment dose, and with comparable cumulative dose to that in patients treated using an age-based stimulus dosing protocol. This was an analysis of data assembled from archived records and based on cohorts of patients treated respectively on an age-based stimulus dosing protocol and on a dose titration protocol in the National Health Service in England. We demonstrated a significantly better response in the patient cohort treated with dose titration than with age-based stimulus dosing. Peak doses were less and the total cumulative dose was less in the dose titration group than in the age-based stimulus dosing group. Our findings are consistent with superior outcomes in patients treated using a dose titration protocol when compared with age-based stimulus dosing in a similar cohort of patients.

  6. Potentiometric titration and equivalent weight of humic acid

    USGS Publications Warehouse

    Pommer, A.M.; Breger, I.A.

    1960-01-01

    The "acid nature" of humic acid has been controversial for many years. Some investigators claim that humic acid is a true weak acid, while others feel that its behaviour during potentiometric titration can be accounted for by colloidal adsorption of hydrogen ions. The acid character of humic acid has been reinvestigated using newly-derived relationships for the titration of weak acids with strong base. Re-interpreting the potentiometric titration data published by Thiele and Kettner in 1953, it was found that Merck humic acid behaves as a weak polyelectrolytic acid having an equivalent weight of 150, a pKa of 6.8 to 7.0, and a titration exponent of about 4.8. Interdretation of similar data pertaining to the titration of phenol-formaldehyde and pyrogallol-formaldehyde resins, considered to be analogs for humic acid by Thiele and Kettner, leads to the conclusion that it is not possible to differentiate between adsorption and acid-base reaction for these substances. ?? 1960.

  7. A systematic review on the effectiveness of titratable over nontitratable mandibular advancement appliances for sleep apnea.

    PubMed

    Sivaramakrishnan, Gowri; Sridharan, Kannan

    2017-01-01

    Mandibular advancement appliances are being tested for use in patients with obstructive sleep apnea (OSA). However, the effectiveness of titration of these appliances does not have conclusive evidence. Systematic reviews help us to compile all available clinical evidence using statistical principles. Hence, the aim of this systematic review is to identify the effectiveness of titratable over nontitratable mandibular advancement appliances in patients with mild to moderate OSA. This review objective is to identify if titration of these appliances produce significant benefits over fixed appliances. Electronic databases were searched to identify eligible studies based on set inclusion criteria. Data extraction form was created and the data were extracted. The participants were mild to moderate OSA patients who received mandibular advancement appliances. Studies included a comparison between titratable and nontitratable mandibular advancement appliance. Of the five included studies, three were observational and two were a randomized trial. All these studies were conducted in adults. The outcome attributes were polysomnographic readings and apnea-hypopnea index (AHI). A significant heterogeneity was seen between the eligible studies and hence a meta-analysis could not be performed. The results from this systematic review did not show significant advantages of titratable appliances, although titratable appliances performed better from individual studies as regards to reduction in AHI and polysomnography. The reason is the lack of sufficient clinical trials on the same. More high quality randomized controlled trials comparing titratable and fixed appliances have to be initiated to get to conclusive evidence.

  8. Antiepileptic Drug Titration and Related Health Care Resource Use and Costs.

    PubMed

    Fishman, Jesse; Kalilani, Linda; Song, Yan; Swallow, Elyse; Wild, Imane

    2018-02-27

    Unexpected breakthrough seizures resulting from suboptimal antiepileptic drug (AED) dosing during the titration period, as well as adverse events resulting from rapid AED titration, may influence the titration schedule and significantly increase health care resource use (HRU) and health care costs. To assess the relationship between AEDs, HRU, and costs during AED titration and maintenance. Practicing neurologists were recruited from a nationwide panel to provide up to 3 patient records each for this retrospective medical chart review. Patients with epilepsy who were aged ≥ 18 years and had initiated an AED between January 1, 2014, and January 1, 2016, were followed for 6 months from AED initiation. Titration duration was the time from AED initiation to the beginning of treatment maintenance as determined by the physician. Outcomes were epilepsy-specific HRU (hospitalizations, emergency department visits, outpatient visits, physician referral, laboratory testing/diagnostic imaging, and phone calls) and related costs that occurred during the titration or maintenance treatment periods. Of 811 patients, 156, 128, 125, 120, 114, 107, and 61 initiated the following AEDs: levetiracetam, lamotrigine, lacosamide, valproate, topiramate, carbamazepine, and phenytoin, respectively. Most patients (619/803 [77.1%] with complete AED data) received monotherapy. Baseline characteristics were similar across AEDs (mean [SD] age, 36.6 [14.4] years; 59.0% male). Kaplan-Meier estimates of titration duration ranged from 3.3 weeks (phenytoin) to 8.1 weeks (lamotrigine). From titration to maintenance, the overall incidence of HRU per person-month decreased 54.5%-89.3% for each HRU measure except outpatient visits (24.6% decrease). Total epilepsy-related costs decreased from $80.48 to $42.77 per person-month, or 46.9% from titration to maintenance. AED titration periods had higher HRU rates and costs than AED maintenance, suggesting that use of AEDs with shorter titration requirements reduces health care costs, although disease severity may also factor into overall cost. UCB Pharma sponsored this study and reviewed the manuscript. Fishman and Kalilani are employees of UCB Pharma. Wild was an employee of UCB Pharma at the time this analysis was conducted. Song and Swallow are employees of Analysis Group, which received funding from UCB Pharma. Study concept and design were contributed by Fishman, Kalilani, and Wild, along with other authors. Data collection was performed by Song and Swallow. All authors contributed to data interpretation. Writing of the manuscript was led by Fishman, Song, and Swallow, with revisions by all authors.

  9. Application of Computers for Experiment Design, Data Acquisition, and Analysis in the Chemistry Laboratory

    DTIC Science & Technology

    1990-05-01

    Obtain Thermistor Operating Characteristics ................................. 82 25. Ag+/Ci" Thermometric Titration ........................... 85 26...Experiment Program for Thermometric Titrations ............... 85 27. Appearance of the Spreadsheet in the Analysis Mode ............ 86 28...rate experiments, carbon dioxide exhalation monitoring, stream turbidity measurement, photosynthesis monitoring, pendulum timing, thermometric titrations

  10. Comparison of methods for accurate end-point detection of potentiometric titrations

    NASA Astrophysics Data System (ADS)

    Villela, R. L. A.; Borges, P. P.; Vyskočil, L.

    2015-01-01

    Detection of the end point in potentiometric titrations has wide application on experiments that demand very low measurement uncertainties mainly for certifying reference materials. Simulations of experimental coulometric titration data and consequential error analysis of the end-point values were conducted using a programming code. These simulations revealed that the Levenberg-Marquardt method is in general more accurate than the traditional second derivative technique used currently as end-point detection for potentiometric titrations. Performance of the methods will be compared and presented in this paper.

  11. Automatic photometric titrations of calcium and magnesium in carbonate rocks

    USGS Publications Warehouse

    Shapiro, L.; Brannock, W.W.

    1955-01-01

    Rapid nonsubjective methods have been developed for the determination of calcium and magnesium in carbonate rocks. From a single solution of the sample, calcium is titrated directly, and magnesium is titrated after a rapid removal of R2O3 and precipitation of calcium as the tungstate. A concentrated and a dilute solution of disodium ethylenediamine tetraacetate are used as titrants. The concentrated solution is added almost to the end point, then the weak solution is added in an automatic titrator to determine the end point precisely.

  12. Determination of organic bases in non-aqueous solvents by catalytic thermometric titration.

    PubMed

    Vajgand, V J; Kiss, T A; Gaál, F F; Zsigrai, I J

    1968-07-01

    Catalytic thermometric titrations have been developed for bases (brucine, diethylaniline, potassium acetate and triethylamine) in acetic acid by continuous and discontinuous addition of the standard solution and automatic temperature recording. The determination of weak bases, e.g., antipyrine, unsuccessful in acetic acid by catalytic thermometric titration, has been achieved by using nitromethane or acetic anhydride as solvent. Catalytic thermometric titrations were also performed by coulometric generation of hydrogen ions for the determination of micro amounts of weak bases in a mixture of acetic anhyride and acetic acid.

  13. Linear Titration Curves of Acids and Bases.

    PubMed

    Joseph, N R

    1959-05-29

    The Henderson-Hasselbalch equation, by a simple transformation, becomes pH - pK = pA - pB, where pA and pB are the negative logarithms of acid and base concentrations. Sigmoid titration curves then reduce to straight lines; titration curves of polyelectrolytes, to families of straight lines. The method is applied to the titration of the dipeptide glycyl aminotricarballylic acid, with four titrable groups. Results are expressed as Cartesian and d'Ocagne nomograms. The latter is of a general form applicable to polyelectrolytes of any degree of complexity.

  14. Titration effectiveness of two autoadjustable continuous positive airway pressure devices driven by different algorithms in patients with obstructive sleep apnoea.

    PubMed

    Damiani, Mario Francesco; Quaranta, Vitaliano Nicola; Tedeschi, Ersilia; Drigo, Riccardo; Ranieri, Teresa; Carratù, Pierluigi; Resta, Onofrio

    2013-08-01

    Nocturnal application of continuous positive airway pressure (CPAP) is the standard treatment for patients with obstructive sleep apnoea (OSA). Determination of the therapeutic pressure (CPAP titration) is usually performed by a technician in the sleep laboratory during attended polysomnography. One possible alternative to manual titration is automated titration. Indeed, during the last 15 years, devices have been developed that deliver autoadjustable CPAP (A-CPAP). The aim of the present study was to compare the titration effectiveness of two A-CPAP devices using different flow-based algorithms in patients with OSA. This is a randomized study; 79 subjects underwent two consecutive unattended home A-CPAP titration nights with two different devices (Autoset Resmed; Remstar Auto Respironics); during the third and the fourth night, patients underwent portable monitoring in the sleep laboratory during fixed CPAP at the A-CPAP recommended pressure. Bland Altman plots showed good agreement between the recommended median and maximal pressure levels obtained with the two devices. A significant improvement was observed in all the sleep parameters by both A-CPAP machines to a similar degree. It was observed that the two A-CPAP devices using different algorithms are equally effective in initial titration of CPAP. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  15. Overall Survival Analysis From a Randomized Phase II Study of Axitinib With or Without Dose Titration in First-Line Metastatic Renal Cell Carcinoma.

    PubMed

    Rini, Brian I; Tomita, Yoshihiko; Melichar, Bohuslav; Ueda, Takeshi; Grünwald, Viktor; Fishman, Mayer N; Uemura, Hirotsugu; Oya, Mototsugu; Bair, Angel H; Andrews, Glen I; Rosbrook, Brad; Jonasch, Eric

    2016-12-01

    In a randomized phase II trial in metastatic renal cell carcinoma (mRCC), objective response rate was significantly higher with axitinib versus placebo titration (54% vs. 34%; 1-sided P = .019). Treatment-naive patients with mRCC (n = 213) received axitinib 5 mg twice per day (b.i.d.) for 4 weeks. Patients meeting dose titration criteria were randomized to receive axitinib 5 mg b.i.d. with axitinib or placebo titration (n = 56 each); 91 patients ineligible for randomization continued axitinib 5 mg b.i.d.; 10 discontinued before randomization. Median overall survival (95% confidence interval [CI]) was 42.7 months (24.7-not estimable) with axitinib titration versus 30.4 months (23.7-45.0) with placebo titration (stratified hazard ratio, 0.785; 95% CI, 0.485-1.272; 1-sided P = .162), and 41.6 months (95% CI, 33.0-not estimable) in nonrandomized patients. Safety data were consistent with previous reports. Median overall survival was numerically longer in patients with first-line mRCC who received axitinib versus placebo titration. No new safety signal was observed after long-term axitinib treatment in first-line mRCC. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. A 24-Week, Randomized, Controlled Study to Evaluate the Tolerability, Safety and Efficacy of 2 Different Titration Schemes of the Rivastigmine Patch in Japanese Patients with Mild to Moderate Alzheimer's Disease.

    PubMed

    Nakamura, Yu; Strohmaier, Christine; Tamura, Kaoru; Kataoka, Naoko; Nakano, Masayuki; Oda, Shoichiro; Nishimura, Kazuma; Homma, Akira

    2015-01-01

    To investigate whether 1-step titration of the rivastigmine patch (initiated at 5 cm(2) and titrated to 10 cm(2) after 4 weeks) is well tolerated in Japanese patients with Alzheimer's disease (AD) as compared to 3-step titration (initiated at 2.5 cm(2) and titrated by 2.5 cm(2) every 4 weeks to 10 cm(2)). A 24-week, multicenter, randomized, double-blind study was conducted in Japan between July 2012 and May 2014. Patients with mild to moderate AD aged 50-85 years were randomized 1:1 to 1-step or 3-step titration of the rivastigmine once-daily patch. The primary endpoint was the proportion of patients with adverse events leading to discontinuation. Of 216 patients randomized, 215 (1-step, n = 107; 3-step, n = 108) were included in the safety analysis. The primary endpoint outcome was 15.0% in the 1-step group and 18.5% in the 3-step group. The observed treatment difference was -3.6% (95% confidence interval: -17.0, 9.6), falling within the prespecified acceptance range. The tolerability of two different titration schemes was similar in Japanese patients with AD.

  17. A 24-Week, Randomized, Controlled Study to Evaluate the Tolerability, Safety and Efficacy of 2 Different Titration Schemes of the Rivastigmine Patch in Japanese Patients with Mild to Moderate Alzheimer's Disease

    PubMed Central

    Nakamura, Yu; Strohmaier, Christine; Tamura, Kaoru; Kataoka, Naoko; Nakano, Masayuki; Oda, Shoichiro; Nishimura, Kazuma; Homma, Akira

    2015-01-01

    Aim To investigate whether 1-step titration of the rivastigmine patch (initiated at 5 cm2 and titrated to 10 cm2 after 4 weeks) is well tolerated in Japanese patients with Alzheimer's disease (AD) as compared to 3-step titration (initiated at 2.5 cm2 and titrated by 2.5 cm2 every 4 weeks to 10 cm2). Methods A 24-week, multicenter, randomized, double-blind study was conducted in Japan between July 2012 and May 2014. Patients with mild to moderate AD aged 50-85 years were randomized 1:1 to 1-step or 3-step titration of the rivastigmine once-daily patch. The primary endpoint was the proportion of patients with adverse events leading to discontinuation. Results Of 216 patients randomized, 215 (1-step, n = 107; 3-step, n = 108) were included in the safety analysis. The primary endpoint outcome was 15.0% in the 1-step group and 18.5% in the 3-step group. The observed treatment difference was −3.6% (95% confidence interval: −17.0, 9.6), falling within the prespecified acceptance range. Conclusion The tolerability of two different titration schemes was similar in Japanese patients with AD. PMID:26557135

  18. A model for oxygen conservation associated with titration during pediatric oxygen therapy

    PubMed Central

    Wu, Grace; Wollen, Alec; Himley, Stephen; Austin, Glenn; Delarosa, Jaclyn; Izadnegahdar, Rasa; Ginsburg, Amy Sarah; Zehrung, Darin

    2017-01-01

    Background Continuous oxygen treatment is essential for managing children with hypoxemia, but access to oxygen in low-resource countries remains problematic. Given the high burden of pneumonia in these countries and the fact that flow can be gradually reduced as therapy progresses, oxygen conservation through routine titration warrants exploration. Aim To determine the amount of oxygen saved via titration during oxygen therapy for children with hypoxemic pneumonia. Methods Based on published clinical data, we developed a model of oxygen flow rates needed to manage hypoxemia, assuming recommended flow rate at start of therapy, and comparing total oxygen used with routine titration every 3 minutes or once every 24 hours versus no titration. Results Titration every 3 minutes or every 24 hours provided oxygen savings estimated at 11.7% ± 5.1% and 8.1% ± 5.1% (average ± standard error of the mean, n = 3), respectively. For every 100 patients, 44 or 30 kiloliters would be saved—equivalent to 733 or 500 hours at 1 liter per minute. Conclusions Ongoing titration can conserve oxygen, even performed once-daily. While clinical validation is necessary, these findings could provide incentive for the routine use of pulse oximeters for patient management, as well as further development of automated systems. PMID:28234903

  19. Clozapine Titration for People in Early Psychosis: A Chart Review and Treatment Guideline.

    PubMed

    Ballon, Jacob S; Ashfaq, Hera; Noordsy, Douglas L

    2018-06-01

    The use of clozapine, particularly in young people, is often limited by early treatment-emergent adverse effects including drowsiness and lethargy. Concerns about adverse effects, medication adherence, and the need for blood monitoring often impede the use of clozapine in this population, leading to repeated trials of less effective medications. Current clozapine dosing recommendations are based on people further in the course of their illness and thus reflect different responsiveness and sensitivities to antipsychotic medication. As such, there is a need for evidence-based guidelines for titration and dosing of clozapine among people in early psychosis. We performed a chart review of 14 people treated with clozapine within our early psychosis team. Data regarding dose titration, response, time to discontinuation, symptom severity, weight gain, and other adverse effects were gathered at clozapine initiation, 3 months, and last available visit on clozapine. People treated with slow titration within their first year of psychosis onset achieved sustained response at very low maintenance doses (mean dose = 81 mg/d, mean duration of treatment = 200 weeks) compared with slow titration with longer duration of illness (mean dose = 350 mg/d, mean duration of treatment = 68 weeks) or standard dose titration in early psychosis (mean dose = 112 mg/d, mean duration of treatment = 38 weeks). The most common adverse effects in all groups were weight gain and sedation, with the groups requiring higher mean doses reporting a broader range of adverse effects. There was no apparent difference in the clinical global impression for severity or improvement between the slow titration and standard titration groups in people with early psychosis. These observations are synthesized into a proposed treatment guideline for use of clozapine among people in early psychosis. We describe development of a slow titration approach to initiating clozapine among people in early psychosis. This approach resulted in clinical response at remarkably low maintenance doses of clozapine among people within their first year of illness, but not in those with longer duration of symptoms. Slow titration also led to good tolerability and acceptance of clozapine treatment for some patients.

  20. Oxygen titration after resuscitation from out-of-hospital cardiac arrest: A multi-centre, randomised controlled pilot study (the EXACT pilot trial).

    PubMed

    Bray, Janet E; Hein, Cindy; Smith, Karen; Stephenson, Michael; Grantham, Hugh; Finn, Judith; Stub, Dion; Cameron, Peter; Bernard, Stephen

    2018-04-21

    Recent studies suggest the administration of 100% oxygen to hyperoxic levels following return-of-spontaneous-circulation (ROSC) post-cardiac arrest may be harmful. However, the feasibility and safety of oxygen titration in the prehospital setting is unknown. We conducted a multi-centre, phase-2 study testing whether prehospital titration of oxygen results in an equivalent number of patients arriving at hospital with oxygen saturations SpO2 ≥ 94%. We enrolled unconscious adults with: sustained ROSC; initial shockable rhythm; an advanced airway; and an SpO2 ≥ 95%. Initially (Sept 2015-March 2016) patients were randomised 1:1 to either 2 L/minute (L/min) oxygen (titrated) or >10 L/min oxygen (control) via a bag-valve reservoir. However, one site experienced a high number of desaturations (SpO2 < 94%) in the titrated arm and this arm was changed (April 2016) to an initial reduction of oxygen to 4 L/min then, if tolerated, to 2 L/min, and the desaturation limit was decreased to <90%. We randomised 61 patients to titrated (n = 37: 2L/min = 20 and 2-4 L/min = 17) oxygen or control (n = 24). Patients allocated to titrated oxygen were more likely to desaturate compared to controls ((SpO2 < 94%: 43% vs. 4%, p = 0.001; SpO2 < 90%: 19% vs. 4%, p = 0.09). The majority of desaturations (81%) occurred at 2L/min. On arrival at hospital the majority of patients had a SpO2 ≥ 94% (titrated: 90% vs. control: 100%) and all patients had a SpO2 ≥ 90%. One patient (control) re-arrested. Survival to hospital discharge was similar. Oxygen titration post-ROSC is feasible in the prehospital environment, but incremental titration commencing at 4L/min oxygen flow may be needed to maintain an oxygen saturation >90% (NCT02499042). Copyright © 2018 Elsevier B.V. All rights reserved.

  1. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Method A Appendix A to Part 425 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium ferricyanide titration method is based on method SLM 4/2 described in “Official Method of Analysis,” Society of Leather Trades...

  2. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Method A Appendix A to Part 425 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., App. A Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium ferricyanide titration method is based on method SLM 4/2 described in “Official Method of Analysis,” Society of...

  3. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Method A Appendix A to Part 425 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium ferricyanide titration method is based on method SLM 4/2 described in “Official Method of Analysis,” Society of Leather Trades...

  4. Ascorbic Acid as a Standard for Iodometric Titrations. An Analytical Experiment for General Chemistry

    NASA Astrophysics Data System (ADS)

    Silva, Cesar R.; Simoni, Jose A.; Collins, Carol H.; Volpe, Pedro L. O.

    1999-10-01

    Ascorbic acid is suggested as the weighable compound for the standardization of iodine solutions in an analytical experiment in general chemistry. The experiment involves an iodometric titration in which iodine reacts with ascorbic acid, oxidizing it to dehydroascorbic acid. The redox titration endpoint is determined by the first iodine excess that is complexed with starch, giving a deep blue-violet color. The results of the titration of iodine solution using ascorbic acid as a calibration standard were compared with the results acquired by the classic method using a standardized solution of sodium thiosulfate. The standardization of the iodine solution using ascorbic acid was accurate and precise, with the advantages of saving time and avoiding mistakes due to solution preparation. The colorless ascorbic acid solution gives a very clear and sharp titration end point with starch. It was shown by thermogravimetric analysis that ascorbic acid can be dried at 393 K for 2 h without decomposition. This experiment allows general chemistry students to perform an iodometric titration during a single laboratory period, determining with precision the content of vitamin C in pharmaceutical formulations.

  5. Risk factors associated with treatment discontinuation and down-titration in type 2 diabetes patients treated with sulfonylureas.

    PubMed

    Iglay, Kristy; Qiu, Ying; Steve Fan, Chun-Po; Li, Zhiyi; Tang, Jackson; Laires, Pedro

    2016-09-01

    Sulfonylurea therapy among patients with type 2 diabetes mellitus (T2DM) can be disrupted due to adverse events, including hypoglycemia. A retrospective study using the MarketScan claims database quantified the frequency of sulfonylurea discontinuation or down-titration and identified associated risk factors. Adult patients with an index sulfonylurea prescription between 2008 and 2012 and 1 year continuous enrollment pre- and post-index were included. Therapy changes assessed over 1 year post-index included discontinuation and down-titration. Discontinuation occurred if the date of a fill was >90 days from the end date of the preceding fill. Down-titration occurred when a fill had a lower equivalent dose than the fill on the index date. Kaplan-Meier methods estimated the probability of either discontinuation or down-titration over 12 months, and Cox regression models identified associated risk factors. A total of 104,082 sulfonylurea users were included in the study and the probability of either discontinuation or down-titration at 3, 6 and 12 months was 23.2%, 38.9%, and 52.3%, respectively. Major risk factors associated with therapy changes included post-index hypoglycemia (discontinuation hazard ratio [HR] = 1.78 [1.68, 1.89]; down-titration HR =2.79 [2.40, 3.23]) and concomitant use of insulin (discontinuation HR =1.48 [1.40, 1.57]; down-titration HR =1.82 [1.56, 2.11]). Other risk factors included younger age, female gender, use of second generation sulfonylureas, prior cardiovascular comorbidity and liver disease. The study was not able to assess unreported, potentially mild cases of hypoglycemia, nor was it able to evaluate the association between changes in therapy and HbA1c levels or body weight. More than half of T2DM patients who initiated sulfonylurea therapy discontinued or down-titrated within 1 year. Insulin use and hypoglycemia were associated with sulfonylurea therapy change.

  6. Dose Titration of Pregabalin in Patients with Painful Diabetic Peripheral Neuropathy: Simulation Based on Observational Study Patients Enriched with Data from Randomized Studies.

    PubMed

    Alexander, Joe; Edwards, Roger A; Manca, Luigi; Grugni, Roberto; Bonfanti, Gianluca; Emir, Birol; Whalen, Edward; Watt, Stephen; Parsons, Bruce

    2018-03-01

    Achieving a therapeutic response to pregabalin in patients with painful diabetic peripheral neuropathy (pDPN) requires adequate upward dose titration. Our goal was to identify relationships between titration and response to pregabalin in patients with pDPN. Data were integrated from nine randomized, placebo-controlled clinical trials as well as one 6-week open-label observational study conducted by 5808 physicians (2642 patients with pDPN) in standard outpatient settings in Germany. These studies evaluated pregabalin for treatment of pDPN. Using these data, we examined "what if" scenarios using a microsimulation platform that integrates data from randomized and observational sources as well as autoregressive-moving-average with exogenous inputs models that predict pain outcomes, taking into account weekly changes in pain, sleep interference, dose, and other patient characteristics that were unchanging. Final pain levels were significantly different depending on dose changes (P < 0.0001), with greater proportions improving with upward titration regardless of baseline pain severity. Altogether, 78.5% of patients with pDPN had 0-1 dose change, and 15.2% had ≥ 2 dose changes. Simulation demonstrated that the 4.8% of inadequately titrated patients who did not improve/very much improve their pain levels would have benefited from ≥ 2 dose changes. Patient satisfaction with tolerability (range 90.3-96.2%) was similar, regardless of baseline pain severity, number of titrations, or extent of improvement, suggesting that tolerability did not influence treatment response patterns. Upward dose titration reduced pain in patients with pDPN who actually received it. Simulation also predicted pain reduction in an inadequately titrated nonresponder subgroup of patients had they actually received adequate titration. The decision not to uptitrate must have been driven by factors other than tolerability. Pfizer, Inc.

  7. Lacosamide and sodium channel-blocking antiepileptic drug cross-titration against levetiracetam background therapy.

    PubMed

    Baulac, M; Byrnes, W; Williams, P; Borghs, S; Webster, E; De Backer, M; Dedeken, P

    2017-04-01

    To assess prospectively the effectiveness of lacosamide (LCM) added to levetiracetam (LEV) after down-titration of a concomitant sodium channel blocker (SCB) among patients with focal epilepsy not adequately controlled on LEV and SCB. In this open-label trial, LCM was initiated at 100 mg/day and up-titrated to 200-600 mg/day over 9 weeks; SCB down-titration started when LCM dose reached 200 mg/day. Patients remained on stable LCM/LEV doses for 12 weeks' maintenance (21-week treatment period). The primary outcome was retention rate on LCM. Due to recruitment challenges, fewer than the planned 300 patients participated in the trial, resulting in the trial being underpowered. Overall, 120 patients (mean age 39.7 years) started and 93 completed the trial. The most frequently used SCBs were lamotrigine (39.2%), carbamazepine (30.8%) and oxcarbazepine (27.5%). Eighty-four patients adhered to protocol and discontinued their SCB after cross-titration, but there was insufficient evidence for 36 patients. Retention rate was 73.3% (88/120) for all patients and 83.3% (70/84) for those with evidence of SCB discontinuation. Seizure freedom for patients completing maintenance was 14.0% (13/93). Discontinuation due to adverse events (6.7%) and lack of efficacy (3.3%) occurred primarily during cross-titration. Most frequently reported adverse events during treatment were dizziness (23.3%), headache (15.0%) and fatigue (8.3%). In patients with uncontrolled seizures on LEV/SCB, the LCM/LEV combination appeared to be effective and well tolerated. A cross-titration schedule-flexible LCM up-titration, concomitant SCB down-titration and stable background LEV-could present a feasible and practical approach to initiating LCM while minimizing pharmacodynamic interactions with a SCB. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level.

    PubMed

    Sahoo, P; Ananthanarayanan, R; Malathi, N; Rajiniganth, M P; Murali, N; Swaminathan, P

    2010-06-11

    A simple but high performance potentiometric titration technique using pulsating sensors has been developed for assay of dissolved oxygen (DO) in water samples down to 10.0 microg L(-1) levels. The technique involves Winkler titration chemistry, commonly used for determination of dissolved oxygen in water at mg L(-1) levels, with modification in methodology for accurate detection of end point even at 10.0 microg L(-1) levels DO present in the sample. An indigenously built sampling cum pretreatment vessel has been deployed for collection and chemical fixing of dissolved oxygen in water samples from flowing water line without exposure to air. A potentiometric titration facility using pulsating sensors developed in-house is used to carry out titration. The power of the titration technique has been realised in estimation of very dilute solution of iodine equivalent to 10 microg L(-1) O(2). Finally, several water samples containing dissolved oxygen from mg L(-1) to microg L(-1) levels were successfully analysed with excellent reproducibility using this new technique. The precision in measurement of DO in water at 10 microg L(-1) O(2) level is 0.14 (n=5), RSD: 1.4%. Probably for the first time a potentiometric titration technique has been successfully deployed for assay of dissolved oxygen in water samples at 10 microg L(-1) levels. Copyright 2010 Elsevier B.V. All rights reserved.

  9. Evaluation of the 5 and 8 pH point titration methods for monitoring anaerobic digesters treating solid waste.

    PubMed

    Vannecke, T P W; Lampens, D R A; Ekama, G A; Volcke, E I P

    2015-01-01

    Simple titration methods certainly deserve consideration for on-site routine monitoring of volatile fatty acid (VFA) concentration and alkalinity during anaerobic digestion (AD), because of their simplicity, speed and cost-effectiveness. In this study, the 5 and 8 pH point titration methods for measuring the VFA concentration and carbonate system alkalinity (H2CO3*-alkalinity) were assessed and compared. For this purpose, synthetic solutions with known H2CO3*-alkalinity and VFA concentration as well as samples from anaerobic digesters treating three different kind of solid wastes were analysed. The results of these two related titration methods were verified with photometric and high-pressure liquid chromatography measurements. It was shown that photometric measurements lead to overestimations of the VFA concentration in the case of coloured samples. In contrast, the 5 pH point titration method provides an accurate estimation of the VFA concentration, clearly corresponding with the true value. Concerning the H2CO3*-alkalinity, the most accurate and precise estimations, showing very similar results for repeated measurements, were obtained using the 8 pH point titration. Overall, it was concluded that the 5 pH point titration method is the preferred method for the practical monitoring of AD of solid wastes due to its robustness, cost efficiency and user-friendliness.

  10. A Full Automatic Device for Sampling Small Solution Volumes in Photometric Titration Procedure Based on Multicommuted Flow System

    PubMed Central

    Borges, Sivanildo S.; Vieira, Gláucia P.; Reis, Boaventura F.

    2007-01-01

    In this work, an automatic device to deliver titrant solution into a titration chamber with the ability to determine the dispensed volume of solution, with good precision independent of both elapsed time and flow rate, is proposed. A glass tube maintained at the vertical position was employed as a container for the titrant solution. Electronic devices were coupled to the glass tube in order to control its filling with titrant solution, as well as the stepwise solution delivering into the titration chamber. The detection of the titration end point was performed employing a photometer designed using a green LED (λ=545 nm) and a phototransistor. The titration flow system comprised three-way solenoid valves, which were assembled to allow that the steps comprising the solution container loading and the titration run were carried out automatically. The device for the solution volume determination was designed employing an infrared LED (λ=930 nm) and a photodiode. When solution volume delivered from proposed device was within the range of 5 to 105 μl, a linear relationship (R = 0.999) between the delivered volumes and the generated potential difference was achieved. The usefulness of the proposed device was proved performing photometric titration of hydrochloric acid solution with a standardized sodium hydroxide solution and using phenolphthalein as an external indicator. The achieved results presented relative standard deviation of 1.5%. PMID:18317510

  11. Effects of Acute and Chronic Cocaine Administration on Titrating-Delay Matching-to-Sample Performance

    ERIC Educational Resources Information Center

    Kangas, Brian D.; Branch, Marc N.

    2012-01-01

    The effects of cocaine were examined under a titrating-delay matching-to-sample procedure. In this procedure, the delay between sample stimulus offset and comparison stimuli onset adjusts as a function of the subject's performance. Specifically, matches increase the delay and mismatches decrease the delay. Titrated delay values served as the…

  12. Quantitative Analysis of Sulfate in Water by Indirect EDTA Titration

    ERIC Educational Resources Information Center

    Belle-Oudry, Deirdre

    2008-01-01

    The determination of sulfate concentration in water by indirect EDTA titration is an instructive experiment that is easily implemented in an analytical chemistry laboratory course. A water sample is treated with excess barium chloride to precipitate sulfate ions as BaSO[subscript 4](s). The unprecipitated barium ions are then titrated with EDTA.…

  13. The Quantitative Resolution of a Mixture of Group II Metal Ions by Thermometric Titration with EDTA. An Analytical Chemistry Experiment.

    ERIC Educational Resources Information Center

    Smith, Robert L.; Popham, Ronald E.

    1983-01-01

    Presents an experiment in thermometric titration used in an analytic chemistry-chemical instrumentation course, consisting of two titrations, one a mixture of calcium and magnesium, the other of calcium, magnesium, and barium ions. Provides equipment and solutions list/specifications, graphs, and discussion of results. (JM)

  14. Microscale pH Titrations Using an Automatic Pipet.

    ERIC Educational Resources Information Center

    Flint, Edward B.; Kortz, Carrie L.; Taylor, Max A.

    2002-01-01

    Presents a microscale pH titration technique that utilizes an automatic pipet. A small aliquot (1-5 mL) of the analyte solution is titrated with repeated additions of titrant, and the pH is determined after each delivery. The equivalence point is determined graphically by either the second derivative method or a Gran plot. The pipet can be…

  15. Acid-base titrations for polyacids: Significance of the pK sub a and parameters in the Kern equation

    NASA Technical Reports Server (NTRS)

    Meites, L.

    1978-01-01

    A new method is suggested for calculating the dissociation constants of polyvalent acids, especially polymeric acids. In qualitative form the most significant characteristics of the titration curves are demonstrated and identified which are obtained when titrating the solutions of such acids with a standard base potentiometrically.

  16. Determination of Titratable Acidity in Wine Using Potentiometric, Conductometric, and Photometric Methods

    ERIC Educational Resources Information Center

    Volmer, Dietrich A.; Curbani, Luana; Parker, Timothy A.; Garcia, Jennifer; Schultz, Linda D.; Borges, Endler Marcel

    2017-01-01

    This experiment describes a simple protocol for teaching acid-base titrations using potentiometry, conductivity, and/or photometry to determine end points without an added indicator. The chosen example examines the titratable acidity of a red wine with NaOH. Wines contain anthocyanins, the colors of which change with pH. Importantly, at the…

  17. Improving medication titration in heart failure by embedding a structured medication titration plan.

    PubMed

    Hickey, Annabel; Suna, Jessica; Marquart, Louise; Denaro, Charles; Javorsky, George; Munns, Andrew; Mudge, Alison; Atherton, John J

    2016-12-01

    To improve up-titration of medications to target dose in heart failure patients by improving communication from hospital to primary care. This quality improvement project was undertaken within three heart failure disease management (HFDM) services in Queensland, Australia. A structured medication plan was collaboratively designed and implemented in an iterative manner, using methods including awareness raising and education, audit and feedback, integration into existing work practice, and incentive payments. Evaluation was undertaken using sequential audits, and included process measures (use of the titration plan, assignment of responsibility) and outcome measures (proportion of patients achieving target dose) in HFDM service patients with reduced left ventricular ejection fraction. Comparison of the three patient cohorts (pre-intervention cohort A n=96, intervention cohort B n=95, intervention cohort C n=89) showed increase use of the titration plan, a shift to greater primary care responsibility for titration, and an increase in the proportion of patients achieving target doses of angiotensin converting enzyme inhibitors/angiotensin receptor blockers (ACEI/ARB) (A 37% vs B 48% vs C 55%, p=0.051) and beta-blockers (A 38% vs B 33% vs C 51%, p=0.045). Combining all three cohorts, patients not on target doses when discharged from hospital were more likely to achieve target doses of ACEI/ARB (p<0.0001) and beta blockers (p<0.0001) within six months if they received a medication titration plan. A medication titration plan was successfully implemented in three HFDM services and improved transitional communication and achievement of target doses of evidence-based therapies within six months of hospital discharge. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Does a patient-managed insulin intensification strategy with insulin glargine and insulin glulisine provide similar glycemic control as a physician-managed strategy? Results of the START (Self-Titration With Apidra to Reach Target) Study: a randomized noninferiority trial.

    PubMed

    Harris, Stewart B; Yale, Jean-François; Berard, Lori; Stewart, John; Abbaszadeh, Babak; Webster-Bogaert, Susan; Gerstein, Hertzel C

    2014-01-01

    OBJECTIVE Diabetes self-management is universally regarded as a foundation of diabetes care. We determined whether comparable glycemic control could be achieved by self-titration versus physician titration of a once-daily bolus insulin dose in patients with type 2 diabetes who are unable to achieve optimal glycemia control with a basal insulin. RESEARCH DESIGN AND METHODS Patients with type 2 diabetes, an HbA1c level >7% (53 mmol/mol), and either nocturnal hypoglycemia episodes or an insufficient basal insulin glargine level (with or without oral agents) to achieve a fasting plasma glucose level ≤6 mmol/L (108 mg/dL) were studied. Participants all had bolus insulin glulisine added at breakfast and were allocated to either algorithm-guided patient self-titration or physician titration. The primary outcome was an HbA1c level ≤7% (53 mmol/mol) without severe hypoglycemia. RESULTS After a mean (SD) follow-up of 159.4 days (36.2 days), 28.4% of participants in the self-titration arm vs. 21.2% in the physician titration arm achieved an HbA1c level of ≤7% (53 mmol/mol) without severe hypoglycemia (between-group absolute difference 7.2%; 95% CI -3.2 to 17.7). The lower end of this 95% confidence interval was within the predetermined noninferiority boundary of -5% (P noninferiority = 0.011). CONCLUSIONS In stable patients with type 2 diabetes who are receiving doses of basal insulin glargine who require bolus insulin, a simple bolus insulin patient-managed titration algorithm is as effective as a physician-managed algorithm.

  19. Rapid clozapine titration in treatment-refractory bipolar disorder.

    PubMed

    Ifteni, Petru; Correll, Christoph U; Nielsen, Jimmi; Burtea, Victoria; Kane, John M; Manu, Peter

    2014-09-01

    Clozapine is effective in treatment-refractory bipolar disorder (BD). Guidelines recommend slow titration to prevent seizures, hypotension and myocarditis, but this stance is not supported by comparative data. To evaluate the safety and effectiveness of rapid clozapine titration in BD. Analysis of a consecutive cohort of treatment-refractory BD patients with mixed/manic episode admitted on alternate days to one of two units of a psychiatric hospital. On one unit, clozapine was started at 25mg followed by 25-50mg as needed every 6h (maximum=100mg/day) on day 1, followed by increases of 25-100mg/day. On the other unit, clozapine was initiated with 25mg in day 1, followed by increases of 25-50mg/day. The primary outcome was the number of days from starting clozapine until readiness for discharge, adjusted in logistic regression for the number of antipsychotics tried during the hospitalization, psychotropic co-treatments and presence of psychotic features. Patients subject to rapid (N=44) and standard (N=23) titration were similar in age, gender, smoking status, body mass index, illness severity at baseline and discharge, and highest clozapine dose. Clozapine was discontinued due to hypotension (N=1) and pneumonia (N=1) during rapid titration, and for excessive sedation (N=1) in each titration group. The number of hospital days from starting clozapine until readiness for discharge was 3.8 days shorter in the rapid titration group (12.7±6.3 vs. 16.5±5.8, p=0.0077). Rapid clozapine titration appeared safe and effective for treatment-refractory BD. The potential for shorter hospital stays justifies prospective trials of this method. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Clinical, polysomnographic, and CPAP titration features of obstructive sleep apnea: Mixed versus purely obstructive type.

    PubMed

    Lee, Sang-Ahm; Lee, Gha-Hyun; Chung, Yoo-Sam; Kim, Woo Sung

    2015-08-15

    To determine whether obstructive sleep apnea syndrome (OSAS) patients with mixed sleep apnea (MSA) have different clinical, polysomnographic, and continuous positive airway pressure (CPAP) titration findings compared to OSAS patients without MSA. We retrospectively reviewed the records of OSAS patients who had undergone CPAP titration and categorized them into pure-OSA and mixed-OSA groups. Demographic features, daytime sleepiness, and apnea severity were compared between the two groups using univariate and multivariate analyses. CPAP titration findings were also compared between the two groups. One hundred and ninety-five subjects (n=126 pure-OSA; n=69 mixed-OSA) were included in the analysis. Compared to the pure-OSA group, the mixed-OSA group had a higher percentage of males (p=0.003) and a higher body mass index (p=0.044), Epworth Sleepiness Scale score (p=0.028), and apnea-hypopnea index (AHI) (p<0.001). In logistic regression analysis, older age, male sex, and higher body mass index were independently associated with mixed-OSA before PSG study. When using AHI as a covariable, the higher AHI with older age, male sex, and daytime sleepiness was independently related to mixed-OSA. The mixed-OSA group had a higher percentage of patients with complex sleep apnea, a lower percentage of patients with optimal titration, and a higher titrated pressure than the pure-OSA group. Severe OSA, older age, male sex, obesity, and daytime sleepiness were related to mixed-OSA. Complex sleep apnea, less optimal titration, and a higher titrated CPAP were also associated with MSA in OSAS patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Fluorometric titration approach for calibration of quantity of binding site of purified monoclonal antibody recognizing epitope/hapten nonfluorescent at 340 nm.

    PubMed

    Yang, Xiaolan; Hu, Xiaolei; Xu, Bangtian; Wang, Xin; Qin, Jialin; He, Chenxiong; Xie, Yanling; Li, Yuanli; Liu, Lin; Liao, Fei

    2014-06-17

    A fluorometric titration approach was proposed for the calibration of the quantity of monoclonal antibody (mcAb) via the quench of fluorescence of tryptophan residues. It applied to purified mcAbs recognizing tryptophan-deficient epitopes, haptens nonfluorescent at 340 nm under the excitation at 280 nm, or fluorescent haptens bearing excitation valleys nearby 280 nm and excitation peaks nearby 340 nm to serve as Förster-resonance-energy-transfer (FRET) acceptors of tryptophan. Titration probes were epitopes/haptens themselves or conjugates of nonfluorescent haptens or tryptophan-deficient epitopes with FRET acceptors of tryptophan. Under the excitation at 280 nm, titration curves were recorded as fluorescence specific for the FRET acceptors or for mcAbs at 340 nm. To quantify the binding site of a mcAb, a universal model considering both static and dynamic quench by either type of probes was proposed for fitting to the titration curve. This was easy for fitting to fluorescence specific for the FRET acceptors but encountered nonconvergence for fitting to fluorescence of mcAbs at 340 nm. As a solution, (a) the maximum of the absolute values of first-order derivatives of a titration curve as fluorescence at 340 nm was estimated from the best-fit model for a probe level of zero, and (b) molar quantity of the binding site of the mcAb was estimated via consecutive fitting to the same titration curve by utilizing such a maximum as an approximate of the slope for linear response of fluorescence at 340 nm to quantities of the mcAb. This fluorometric titration approach was proved effective with one mcAb for six-histidine and another for penicillin G.

  2. Titration ELISA as a Method to Determine the Dissociation Constant of Receptor Ligand Interaction.

    PubMed

    Eble, Johannes A

    2018-02-15

    The dissociation constant describes the interaction between two partners in the binding equilibrium and is a measure of their affinity. It is a crucial parameter to compare different ligands, e.g., competitive inhibitors, protein isoforms and mutants, for their binding strength to a binding partner. Dissociation constants are determined by plotting concentrations of bound versus free ligand as binding curves. In contrast, titration curves, in which a signal that is proportional to the concentration of bound ligand is plotted against the total concentration of added ligand, are much easier to record. The signal can be detected spectroscopically and by enzyme-linked immunosorbent assay (ELISA). This is exemplified in a protocol for a titration ELISA that measures the binding of the snake venom-derived rhodocetin to its immobilized target domain of α2β1 integrin. Titration ELISAs are versatile and widely used. Any pair of interacting proteins can be used as immobilized receptor and soluble ligand, provided that both proteins are pure, and their concentrations are known. The difficulty so far has been to determine the dissociation constant from a titration curve. In this study, a mathematical function underlying titration curves is introduced. Without any error-prone graphical estimation of a saturation yield, this algorithm allows processing of the raw data (signal intensities at different concentrations of added ligand) directly by mathematical evaluation via non-linear regression. Thus, several titration curves can be recorded simultaneously and transformed into a set of characteristic parameters, among them the dissociation constant and the concentration of binding-active receptor, and they can be evaluated statistically. When combined with this algorithm, titration ELISAs gain the advantage of directly presenting the dissociation constant. Therefore, they may be used more efficiently in the future.

  3. Determination of the titratable acidity and the pH of wine based on potentiometric flow injection analysis.

    PubMed

    Vahl, Katja; Kahlert, Heike; von Mühlen, Lisandro; Albrecht, Anja; Meyer, Gabriele; Behnert, Jürgen

    2013-07-15

    A FIA system using a pH-sensitive detector based on a graphite/quinhydrone/silicone composite electrode was applied to determine sequentially the titratable acidity and the pH of wine, as well as the sum of calcium and magnesium ions. For all measurements the same FIA configuration was used employing different carrier solutions. The results for the determination of acidity and pH are in good agreement with those obtained by classical potentiometric titrations and by pH measurements using a conventional glass electrode. The standard deviation was less than 1.5% for both kinds of measurements and the sample volume was 150 μL. The method allows about 40 determinations of titratable acidity per hour and 30 pH measurements per hour. The titration method can be adjusted to the legal requirements in USA and Europe. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Acid-base properties of the alumina surface: influence of the titration procedures on the microcalorimetric results.

    PubMed

    Morel, Jean-Pierre; Marmier, Nicolas; Hurel, Charlotte; Morel-Desrosiers, Nicole

    2009-10-01

    The enthalpy changes associated with the protonation and deprotonation of an alumina surface have been determined on the basis of microcalorimetry experiments and acid-base potentiometric titrations at 25 degrees C. It has been shown that the results may vary significantly according to the experimental procedure. In order to do so, the potentiometric and microcalorimetric titrations have been carried out first from an acidic pH to basic pH and second from a pH near the pH(zpc) of alumina to acidic or basic pH. It has been demonstrated that the pK(a) values deduced from the potentiometric titrations are the same whatever the experimental protocol whereas the only way to obtain meaningful enthalpies of proton exchange is to carry out microcalorimetric titrations by starting around the point of zero charge.

  5. Levothyroxine Tablet Malabsorption Associated with Gastroparesis Corrected with Gelatin Capsule Formulation.

    PubMed

    Reardon, David P; Yoo, Peter S

    2016-01-01

    Treatment of hypothyroidism with levothyroxine sodium often requires multiple dose adjustments and can be complicated by patients with gastric and intestinal dysfunction that limits absorption. In these cases, doses are often titrated higher than commonly used in clinical practice. Multiple formulations of levothyroxine are currently available and some may be preferred in cases of malabsorption. We report a case of a 42-year-old female who presented with a living unrelated kidney transplant evaluation with myxedema while being treated with levothyroxine sodium tablets. She was noted to have gastroparesis secondary to Type I diabetes mellitus which may have contributed to levothyroxine malabsorption. Changing to a gelatin capsule formulation quickly corrected her thyroid function assays. This case suggests that gastroparesis may affect absorption of levothyroxine tablets and the gelatin capsules may be an effective alternative therapy.

  6. The design and application of virtual ion meter based on LABVIEW 8.0.

    PubMed

    Meng, Hu; Li, Jiangyuan; Tang, Yonghuai

    2009-08-01

    The virtual ion meter is developed based on LABVIEW 8.0 by homemade adjusting circuit, data acquisition (DAQ) board, and computer. This note provides details of the structure of testing system and flow chart of DAQ program. This virtual instrument system is applied to multitask testing such as determining rate constant of second-order reaction by pX, pX potentiometric titration, determining oscillating reaction by potential, etc. The result of application indicates that this test system not only has function of real-time data acquiring, displaying, storage, but also realizes remote monitoring and controlling test-control spots through internet, automatic analyzing and processing of data, reporting of result according to the different testing task; moreover, the veracity and repeatability of data processing result are higher than the results of manual data processing.

  7. A Laser-Pointer-Based Spectrometer for Endpoint Detection of EDTA Titrations

    ERIC Educational Resources Information Center

    Dahm, Christopher E.; Hall, James W.; Mattioni, Brian E.

    2004-01-01

    A laser spectrometer for the ethylenediaminetetra-acetic acid (EDTA) titration of magnesium or calcium ions that is designed around a handheld laser pointer as the source and a photoresistor as the detector is developed. Findings show that the use of the spectrometer reduces the degree of uncertainty and error in one part of the EDTA titrations,…

  8. Influence of kinetics on the determination of the surface reactivity of oxide suspensions by acid-base titration.

    PubMed

    Duc, M; Adekola, F; Lefèvre, G; Fédoroff, M

    2006-11-01

    The effect of acid-base titration protocol and speed on pH measurement and surface charge calculation was studied on suspensions of gamma-alumina, hematite, goethite, and silica, whose size and porosity have been well characterized. The titration protocol has an important effect on surface charge calculation as well as on acid-base constants obtained by fitting of the titration curves. Variations of pH versus time after addition of acid or base to the suspension were interpreted as diffusion processes. Resulting apparent diffusion coefficients depend on the nature of the oxide and on its porosity.

  9. Determination of the intrinsic redox potentials of FeS centers of respiratory complex I from experimental titration curves

    PubMed Central

    Medvedev, Emile S.; Couch, Vernon A.

    2014-01-01

    Recently, Euro et al. [Biochem. 47, 3185 (2008)] have reported titration data for seven of nine FeS redox centers of complex I from E. coli. There is a significant uncertainty in the assignment of the titration data. Four of the titration curves were assigned to N1a, N1b, N6b, and N2 centers; one curve either to N3 or N7; one more either to N4 or N5; and the last one denoted Nx could not be assigned at all. In addition, the assignment of the titration data to N6b/N6a pair is also uncertain. In this paper, using our calculated interaction energies [Couch et al. BBA 1787, 1266 (2009)], we perform statistical analysis of these data, considering a variety of possible assignments, find the best fit, and determine the intrinsic redox potentials of the centers. The intrinsic potentials could be determined with uncertainty of less than ±10 mV at 95% confidence level for best fit assignments. We also find that the best agreement between theoretical and experimental titration curves is obtained with the N6b-N2 interaction equal to 71±14 or 96±26 mV depending on the N6b/N6a titration data assignment, which is stronger than was expected and may indicate a close distance of N2 center to the membrane surface. PMID:20513348

  10. Non-Aqueous Titration Method for Determining Suppressor Concentration in the MCU Next Generation Solvent (NGS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor-Pashow, Kathryn M. L.; Jones, Daniel H.

    A non-aqueous titration method has been used for quantifying the suppressor concentration in the MCU solvent hold tank (SHT) monthly samples since the Next Generation Solvent (NGS) was implemented in 2013. The titration method measures the concentration of the NGS suppressor (TiDG) as well as the residual tri-n-octylamine (TOA) that is a carryover from the previous solvent. As the TOA concentration has decreased over time, it has become difficult to resolve the TiDG equivalence point as the TOA equivalence point has moved closer. In recent samples, the TiDG equivalence point could not be resolved, and therefore, the TiDG concentration wasmore » determined by subtracting the TOA concentration as measured by semi-volatile organic analysis (SVOA) from the total base concentration as measured by titration. In order to improve the titration method so that the TiDG concentration can be measured directly, without the need for the SVOA data, a new method has been developed that involves spiking of the sample with additional TOA to further separate the two equivalence points in the titration. This method has been demonstrated on four recent SHT samples and comparison to results obtained using the SVOA TOA subtraction method shows good agreement. Therefore, it is recommended that the titration procedure be revised to include the TOA spike addition, and this to become the primary method for quantifying the TiDG.« less

  11. Treatment discontinuation and tolerability as a function of dose and titration of duloxetine in the treatment of major depressive disorder.

    PubMed

    Harada, Eiji; Shirakawa, Osamu; Satoi, Yoichi; Marangell, Lauren B; Escobar, Rodrigo

    2016-01-01

    We sought to better understand how dose and titration with duloxetine treatment may impact tolerability and treatment discontinuation in patients with major depressive disorder. We investigated Phase III duloxetine trials. Group 1 was a single placebo-controlled study with a 20 mg initial dose and a slow titration to 40 and 60 mg. Group 2 was a single study with a 40 mg initial dose and final "active" doses of 40 and 60 mg (5 mg control group), with 1-week titration. Group 3 consisted of eight placebo-controlled studies with starting doses of 40, 60, and 80 mg/day with minimal titration (final dose 40-120 mg/day). Tolerability was measured by rate of discontinuation due to adverse events (DCAE). The DCAE in Group 1 were 3.6% in the 60 mg group, 3.3% in the 40 mg group, and 3.2% in the placebo group. In Group 2, the DCAE were 15.0% in the 60 mg group, 8.1% in the 40 mg group, and 4.9% in the 5 mg group. In Group 3, the DCAE were 9.7% and 4.2% in the duloxetine and placebo groups, respectively. This study suggests that starting dose and titration may have impacted tolerability and treatment discontinuation. A lower starting dose of duloxetine and slower titration may contribute to improving treatment tolerability for patients with major depressive disorder.

  12. Dose titration of repaglinide in patients with inadequately controlled type 2 diabetes.

    PubMed

    Kølendorf, Klaus; Eriksson, Johan; Birkeland, Kåre I; Kjellström, Thomas; Hreidarsson, Astradur B

    2004-04-01

    A total of 385 drug-therapy naïve patients, with inadequately controlled type 2 diabetes, were randomised into a multinational, parallel-group study to compare two strategies for dose titration of the oral hypoglycaemic agent repaglinide. Patients were allocated to either a fasting blood glucose (FBG) monitoring group with titration target 4.4-6.1 mmol/l or to a post-prandial blood glucose (PPBG) monitoring group with titration target 4.4-8.0 mmol/l. An initial titration period of up to 8 weeks was followed by a 12-week treatment period. Glycaemic control and hypoglycaemic outcomes were compared for the respective groups. HbA(1c) decreased significantly more in the FBG monitoring group by a mean of 1.38% compared to the PPBG group by a mean of 1.22% (P=0.03). The glycaemic control targets were met by fewer patients in the FBG group than in the PPBG group (57% versus 86% (P<0.001)) despite a higher mean dose of repaglinide in the FBG group. The within-patient blood glucose variability was significantly lower in the FBG group than in the PPBG group (P<0.001). In conclusion, repaglinide lowered the HbA(1c) effectively and safely in both groups and self-monitored FBG is a suitable parameter for titration of repaglinide. Whether a lower PPBG target might be as good a guide as FBG for titration of repaglinide should be addressed in a future study.

  13. Prescribing and up-titration in recently hospitalized heart failure patients attending a disease management program.

    PubMed

    Carroll, Robert; Mudge, Alison; Suna, Jessica; Denaro, Charles; Atherton, John

    2016-08-01

    Heart failure (HF) medications improve clinical outcomes, with optimal doses defined in clinical trials. Patient, provider and system barriers may limit achievement of optimal doses in real life settings, although disease management programs (HF-DMPs) can facilitate up-titration. Secondary analysis of a prospective cohort of 216 participants recently hospitalized with systolic HF, attending 5 HF-DMPs in Queensland, Australia. Medication history at baseline (6weeks after discharge) and 6months provided data to describe prescription rates, dosage and optimal titration of HF medications, and associations with patient and system factors were explored. At baseline, 94% were on an angiotensin converting enzyme inhibitor/angiotensin II receptor blocker (ACEI/ARB), 94% on a beta-blocker (BB) and 42% on a mineralocorticoid receptor antagonist (MRA). The proportion of participants on optimal doses of ACEI/ARB increased from 38% (baseline) to 52% (6months, p=0.001) and on optimal BB dose from 23% to 49% (p<0.001). Significant barriers to ACEI/ARB up-titration were body mass index (BMI)<25, female gender, polypharmacy, previously diagnosed HF, and tertiary hospital. Significant barriers for BB up-titration were BMI<25, previously diagnosed HF and non-cardiologist care. Effective up-titration in HF DMPs is influenced by patient, disease and service factors. Better understanding of barriers to effective up-titration in women, normal weight, and established HF patients may help provide targeted strategies for improving outcomes in these groups. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Concurrent determination of total serum calcium and magnesium by thermometric titration with ethylenediaminetetraacetate.

    PubMed

    Callicott, R H; Carr, P W

    1976-07-01

    Total serum calcium and magnesium may be determined in one thermometric titration, with disodium ethylenediaminetetraacetate as the titrant. A 1-ml serum sample is diluted with 1 ml of tris(hydroxymethyl)aminomethane buffer (pH 8) and titrated at a constant rate with a motorized syringe buret. Results by the thermometric method compared well with those by atomic absorption spectroscopy.

  15. Randomized clinical trial of an intravenous hydromorphone titration protocol versus usual care for management of acute pain in older emergency department patients.

    PubMed

    Chang, Andrew K; Bijur, Polly E; Davitt, Michelle; Gallagher, E John

    2013-09-01

    Opioid titration is an effective strategy for treating pain; however, titration is generally impractical in the busy emergency department (ED) setting. Our objective was to test a rapid, two-step, hydromorphone titration protocol against usual care in older patients presenting to the ED with acute severe pain. This was a prospective, randomized clinical trial of patients 65 years of age and older presenting to an adult, urban, academic ED with acute severe pain. The study was registered at http://www.clinicaltrials.gov (NCT01429285). Patients randomized to the hydromorphone titration protocol initially received 0.5 mg intravenous hydromorphone. Patients randomized to usual care received any dose of any intravenous opioid. At 15 min, patients in both groups were asked, 'Do you want more pain medication?' Patients in the hydromorphone titration group who answered 'yes' received a second dose of 0.5 mg intravenous hydromorphone. Patients in the usual care group who answered 'yes' had their ED attending physician notified, who then could administer any (or no) additional medication. The primary efficacy outcome was satisfactory analgesia defined a priori as the patient declining additional analgesia at least once when asked at 15 or 60 min after administration of the initial opioid. Dose was calculated in morphine equivalent units (MEU: 1 mg hydromorphone = 7 mg morphine). The need for naloxone to reverse adverse opioid effects was the primary safety outcome. 83.0 % of 153 patients in the hydromorphone titration group achieved satisfactory analgesia compared with 82.5 % of 166 patients in the usual care group (p = 0.91). Patients in the hydromorphone titration group received lower mean initial doses of opioids at baseline than patients in the usual care group (3.5 MEU vs. 4.7 MEU, respectively; p ≤ 0.001) and lower total opioids through 60 min (5.3 MEU vs. 6.0 MEU; p = 0.03). No patient needed naloxone. Low-dose titration of intravenous hydromorphone in increments of 0.5 mg provides comparable analgesia to usual care with less opioid over 60 min.

  16. A randomised controlled trial evaluating IGF1 titration in contrast to current GH dosing strategies in children born small for gestational age: the North European Small-for-Gestational-Age Study.

    PubMed

    Jensen, Rikke Beck; Thankamony, Ajay; O'Connell, Susan M; Kirk, Jeremy; Donaldson, Malcolm; Ivarsson, Sten-A; Söder, Olle; Roche, Edna; Hoey, Hilary; Dunger, David B; Juul, Anders

    2014-10-01

    Short children born small for gestational age (SGA) are treated with a GH dose based on body size, but treatment may lead to high levels of IGF1. The objective was to evaluate IGF1 titration of GH dose in contrast to current dosing strategies. In the North European Small-for-Gestational-Age Study (NESGAS), 92 short pre-pubertal children born SGA were randomised after 1 year of high-dose GH treatment (67 μg/kg per day) to three different regimens: high dose (67 μg/kg per day), low dose (35 μg/kg per day) or IGF1 titration. The average dose during the second year of the randomised trial did not differ between the IGF1 titration group (38 μg/kg per day, s.d. 0.019) and the low-dose group (35 μg/kg per day, s.d. 0.002; P=0.46), but there was a wide variation in the IGF1 titration group (range 10-80 μg/kg per day). The IGF1 titration group had significantly lower height gain (0.17 SDS, s.d. 0.18) during the second year of the randomised trial compared with the high-dose group (0.46 SDS, s.d. 0.25), but not significantly lower than the low-dose group (0.23 SDS, s.d. 0.15; P=0.17). The IGF1 titration group had lower IGF1 levels after 2 years of the trial (mean 1.16, s.d. 1.24) compared with both the low-dose (mean 1.76, s.d. 1.48) and the high-dose (mean 2.97, s.d. 1.63) groups. IGF1 titration of GH dose in SGA children proved less effective than current dosing strategies. IGF1 titration resulted in physiological IGF1 levels with a wide range of GH dose and a poorer growth response, which indicates the role of IGF1 resistance and highlights the heterogeneity of short SGA children. © 2014 European Society of Endocrinology.

  17. Subject-driven titration of biphasic insulin aspart 30 twice daily is non-inferior to investigator-driven titration in Chinese patients with type 2 diabetes inadequately controlled with premixed human insulin: A randomized, open-label, parallel-group, multicenter trial.

    PubMed

    Yang, Wenying; Zhu, Lvyun; Meng, Bangzhu; Liu, Yu; Wang, Wenhui; Ye, Shandong; Sun, Li; Miao, Heng; Guo, Lian; Wang, Zhanjian; Lv, Xiaofeng; Li, Quanmin; Ji, Qiuhe; Zhao, Weigang; Yang, Gangyi

    2016-01-01

    The present study was to compare the efficacy and safety of subject-driven and investigator-driven titration of biphasic insulin aspart 30 (BIAsp 30) twice daily (BID). In this 20-week, randomized, open-label, two-group parallel, multicenter trial, Chinese patients with type 2 diabetes inadequately controlled by premixed/self-mixed human insulin were randomized 1:1 to subject-driven or investigator-driven titration of BIAsp 30 BID, in combination with metformin and/or α-glucosidase inhibitors. Dose adjustment was decided by patients in the subject-driven group after training, and by investigators in the investigator-driven group. Eligible adults (n = 344) were randomized in the study. The estimated glycated hemoglobin (HbA1c) reduction was 14.5 mmol/mol (1.33%) in the subject-driven group and 14.3 mmol/mol (1.31%) in the investigator-driven group. Non-inferiority of subject-titration vs investigator-titration in reducing HbA1c was confirmed, with estimated treatment difference -0.26 mmol/mol (95% confidence interval -2.05, 1.53) (-0.02%, 95% confidence interval -0.19, 0.14). Fasting plasma glucose, postprandial glucose increment and self-measured plasma glucose were improved in both groups without statistically significant differences. One severe hypoglycemic event was experienced by one subject in each group. A similar rate of nocturnal hypoglycemia (events/patient-year) was reported in the subject-driven (1.10) and investigator-driven (1.32) groups. There were 64.5 and 58.1% patients achieving HbA1c <53.0 mmol/mol (7.0%), and 51.2 and 45.9% patients achieving the HbA1c target without confirmed hypoglycemia throughout the trial in the subject-driven and investigator-driven groups, respectively. Subject-titration of BIAsp 30 BID was as efficacious and well-tolerated as investigator-titration. The present study supported patients to self-titrate BIAsp 30 BID under physicians' supervision.

  18. Sleep Quality, Short-Term and Long-Term CPAP Adherence

    PubMed Central

    Somiah, Manya; Taxin, Zachary; Keating, Joseph; Mooney, Anne M.; Norman, Robert G.; Rapoport, David M.; Ayappa, Indu

    2012-01-01

    Study Objectives: Adherence to CPAP therapy is low in patients with obstructive sleep apnea/hypopnea syndrome (OSAHS). The purpose of the present study was to evaluate the utility of measures of sleep architecture and sleep continuity on the CPAP titration study as predictors of both short- and long-term CPAP adherence. Methods: 93 patients with OSAHS (RDI 42.8 ± 34.3/h) underwent in-laboratory diagnostic polysomnography, CPAP titration, and follow-up polysomnography (NPSG) on CPAP. Adherence to CPAP was objectively monitored. Short-term (ST) CPAP adherence was averaged over 14 days immediately following the titration study. Long-term (LT) CPAP adherence was obtained in 56/93 patients after approximately 2 months of CPAP use. Patients were grouped into CPAP adherence groups for ST (< 2 h, 2-4 h, and > 4 h) and LT adherence (< 4 h, > 4 h). Sleep architecture, sleep disordered breathing (SDB) indices, and daytime outcome variables from the diagnostic and titration NPSGs were compared between CPAP adherence groups. Results: There was a significant relationship between ST and LT CPAP adherence (r = 0.81, p < 0.001). Neither ST nor LT adherence were related to demographic variables, baseline severity of untreated SDB, sleep architecture, or measures of daytime impairment. Good CPAP adherence groups had significantly lower %N2 and greater %REM on the titration NPSG. A model combining change in sleep efficiency and change in sleep continuity between the diagnostic and titration NPSGs predicted 17% of the variance in LT adherence (p = 0.006). Conclusions: These findings demonstrate that characteristics of sleep architecture, even on the titration NPSG, may predict some of the variance in CPAP adherence. Better sleep quality on the titration night was related to better CPAP adherence, suggesting that interventions to improve sleep on/prior to the CPAP titration study might be used as a therapeutic intervention to improve CPAP adherence. Citation: Somiah M; Taxin Z; Keating J; Mooney AM; Norman RG; Rapoport DM; Ayappa I. Sleep quality, short-term and long-term CPAP adherence. J Clin Sleep Med 2012;8(5):489-500. PMID:23066359

  19. Electrophoretic separation of alginic sodium diester and sodium hexametaphosphate in chondroitin sulfate that interfere with the cetylpyridinium chloride titration assay.

    PubMed

    Weiguo, Zhang; Giancaspro, Gabriel; Adams, Kristie M; Neal-Kababick, James; Hildreth, Jana; Li, Aishan; Roman, Mark C; Betz, Joseph M

    2014-01-01

    The most commonly used chondroitin sulfate (CS) assay method is cetylpyridinium chloride (CPC) titration. Cellulose acetate membrane electrophoresis (CAME) is the technique used for detection of impurities in the U.S. Pharmacopeia's CS monograph. Because CPC titration is a relatively nonspecific quantitative technique, the apparent amount of CS as determined by CPC titration alone may not reflect the true amount of CS due to possible interference with the CPC assay by impurities that contain CPC titratable functional groups. When CAME is used in conjunction with CPC titration, certain non-CS and adulterants can be visualized and estimated, and a true value for CS can be assigned once the presence of these non-CS impurities has been ruled out. This study examines conjunct application of CPC and CAME in ascertaining CS assay and purity in the presence of certain adulterants. These include propylene glycol alginate sulfate sodium, known in commerce as alginic sodium diester (ASD), and Zero One (Z1), a water-soluble agent newly reported in the CS marketplace and subsequently identified as sodium hexametaphosphate. ASD, Z1, and CS are similar in physical appearance and solubility in water and ethanol. They are also titratable anions and form ionic pairs with CPC, therefore interfering with the CPC titration assay for CS CAME separates these adulterants from each other and from CS by differences in their electrophoretic mobility. CAME is able to detect these impurities in CS at levels as low as 0.66% by weight. Although it is recommended that a method for detecting impurities (e.g., CAME) be used in cormbination with relatively nonspecific assay methods such as CPC titration, this is seldom done in practice. Assay results for CS derived fromn CPC titration may, therefore, be misleading, leaving the CS supply chain vulnerable to adulteration. In this study, the authors investigated ASD and Z1 adulteration of CS and developed an electrophoretic separation of these adulterants in CS and procedures to isolate ASD from CS matrixes containing these adulterants. The authors describe in this paper utilization of an orthogonal approach to establish the identity of Z1 as sodium hexametaphosphate and to confirm the identity of ASD, including ethanol fractionation, FTIR spectroscopy, differential scanning calorimetry, and NMR spectroscopy. The authors suggest that CAME is a cost-effective and easy to use methodfor detecting certain impurities in CS raw ingredients and recommend that CPC and CAME be used in combination by QC laboratories as a means of effectively deterring the practice of adulterating CS raw materials with the known adulterants ASD and Z1 and/or other non-chondroitin substances that can be separated from CSby CAME and that exhibit CPC titration behavior similar to CS.

  20. Analysis of titanium content in titanium tetrachloride solution

    NASA Astrophysics Data System (ADS)

    Bi, Xiaoguo; Dong, Yingnan; Li, Shanshan; Guan, Duojiao; Wang, Jianyu; Tang, Meiling

    2018-03-01

    Strontium titanate, barium titan and lead titanate are new type of functional ceramic materials with good prospect, and titanium tetrachloride is a commonly in the production such products. Which excellent electrochemical performance of ferroelectric tempreature coefficient effect.In this article, three methods are used to calibrate the samples of titanium tetrachloride solution by back titration method, replacement titration method and gravimetric analysis method. The results show that the back titration method has many good points, for example, relatively simple operation, easy to judgment the titration end point, better accuracy and precision of analytical results, the relative standard deviation not less than 0.2%. So, it is the ideal of conventional analysis methods in the mass production.

  1. Correct titration of non-drugs and some other methodological issues.

    PubMed

    Beneke, M; Rasmus, W; Rød, I S; Fritze, J

    1994-01-01

    Doctors' prescription and dosing behaviour was investigated using data from 9 clinical trials in 550 patients treated with psychotropics. 7 trials were conducted under double- and 2 under single-blind conditions. In 3 of these trials, oral and i.m. preparations were used demanding a double-dummy design. All patients were evaluated on a weekly or 2-week basis using psychopathological rating scales (i.e. Hamilton Anxiety Scale, Hamilton Depression Scale, Clinical Global Impressions, Simpson and Angus EPS). It was found that (a) oral-medication titration was 3- to 4-fold more broad-ranging than i.m. medication titration, (b) oral placebo was titrated to the same extent as the oral investigational drugs, and (c) the titration schedule did not follow protocol requirements. Moreover, the average doses in all drug and placebo groups were the same. Concomitant medication like sleep inducers was found to be more closely related to doctors' habits than to actual medical need. Independent of trial and investigational drug, 10-33% of all patients received additional sleep inducers.

  2. An Ion-Selective Electrode for the Determination of Phencyclidine (PCP).

    DTIC Science & Technology

    1980-08-06

    as an indicator_ ectrode in potentiometric titration of PCPA at concentrations DD 1473 EDITION or I Nov soIS OSSOOL TC SEPURqITY CLAWSFICATION Of...and ISE detection limits determined as described previous (25). The PCP electrode was used as the indicator electrode in potentiometric titrations of...was standardized by potentiometric titration with a dodecyltrimethyl- ammonium bromide (DoTAB) solution using a DoTA+ ISE (25) as the indicator

  3. A new titration system of a novel split-type superconducting magnet NMR spectrometer.

    PubMed

    Kitagawa, Isao; Tanaka, Hideki; Okada, Michiya; Kitaguchi, Hitoshi; Kohzuma, Takamitsu

    2008-12-01

    A new titration system for studying protein-ligand interactions has been developed. In this system, the sample solution is circulated in the route formed by an access path in a split superconducting magnet to maintain a constant protein concentration during the titration experiments. A concentration-control procedure for the ligand/protein ratio is devised, and the ligand/protein ratio is well controlled by this apparatus.

  4. [Not Available].

    PubMed

    Burgot, J L

    1978-04-01

    Maleic, fumaric, tartaric, glutaric and adipic acids are titrated directly with sodium hydroxide by means of an automatic thermometric titrimeter. The titration curves have two break-points, corresponding to the successive neutralization of the two acid groups. Previous standardization permits measurement of the heats of neutralization, from which the enthalpies of dissociation can be deduced. From 0.3 to 1 mmole of acid can be titrated with a relative standard deviation of about 3%.

  5. Use of vitreous carbon as a working electrode in coulometric titration of potassium hydrogen phthalate.

    PubMed

    Jennings, V J; Dodson, A; Tedds, G

    1973-07-01

    The use of a vitreous carbon electrode as a cathode in the amperostatic coulometric titration of aqueous potassium hydrogen phthalate solution is described. It is shown that 10 mg of the phthalate can be titrated with a precision better than 0.5%. Current-voltage curves for platinum and vitreous carbon cathodes show that there is an overpotential on the latter relative to the former.

  6. Reduction and determination of dixanthogens.

    PubMed

    Prasad, M S

    1971-06-01

    A convenient method for the reduction and determination of dixaathogen has been developed. It is based on the quantitative reaction of dixanthogen with zinc amalgam to form xanthate; the latter can be determined by iodine titration, potentiometric titration with silver nitrate or by spectrophotometry at 310 mmu. Dixanthogen can be determined in mixtures containing xanthate, by titration of aliquots with and without reduction. Higher dixanthogens can also be determined, and flotation liquors analysed.

  7. A stable and convenient protein electrophoresis titration device with bubble removing system.

    PubMed

    Zhang, Qiang; Fan, Liu-Yin; Li, Wen-Lin; Cong, Feng-Song; Zhong, Ran; Chen, Jing-Jing; He, Yu-Chen; Xiao, Hua; Cao, Cheng-Xi

    2017-07-01

    Moving reaction boundary titration (MRBT) has a potential application to immunoassay and protein content analysis with high selectivity. However, air bubbles often impair the accuracy of MRBT, and the leakage of electrolyte greatly decreases the safety and convenience of electrophoretic titration. Addressing these two issues a reliable MRBT device with modified electrolyte chamber of protein titration was designed. Multiphysics computer simulation was conducted for optimization according to two-phase flow. The single chamber was made of two perpendicular cylinders with different diameters. After placing electrophoretic tube, the resident air in the junction next to the gel could be eliminated by a simple fast electrolyte flow. Removing the electrophoretic tube automatically prevented electrolyte leakage at the junction due to the gravity-induced negative pressure within the chamber. Moreover, the numerical simulation and experiments showed that the improved MRBT device has following advantages: (i) easy and rapid setup of electrophoretic tube within 20 s; (ii) simple and quick bubble dissipates from the chamber of titration within 2 s; (iii) no electrolyte leakage from the two chambers: and (iv) accurate protein titration and safe instrumental operation. The developed technique and apparatus greatly improves the performance of the previous MRBT device, and providing a new route toward practical application. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Comparison of a gel microcolumn assay with the conventional tube test for red blood cell alloantibody titration.

    PubMed

    Finck, Rachel; Lui-Deguzman, Carrie; Teng, Shih-Mao; Davis, Rebecca; Yuan, Shan

    2013-04-01

    Titration is a semiquantitative method used to estimate red blood cell (RBC) alloantibody reactivity. The conventional tube test (CTT) technique is the traditional method for performing titration studies. The gel microcolumn assay (GMA) is also a sensitive method to detect RBC alloantibodies. The aim of this study was to compare a GMA with the CTT technique in the performance of Rh and K alloantibody titration. Patient serum samples that contained an RBC alloantibody with a singular specificity were identified by routine blood bank workflow. Parallel titration studies were performed on these samples by both the CTT method and a GMA (ID-Micro Typing System anti-IgG gel card, Micro Typing Systems, Inc., an Ortho-Clinical Diagnostics Company). Forty-eight samples were included, including 11 anti-D, five anti-c, 13 anti-E, one anti-C, three anti-e, and 15 anti-K. Overall, the two methods generated identical results in 21 of 48 samples. For 42 samples (87.5%) the two methods generated results that were within one serial dilution, and for the remaining six samples, results were within two dilutions. GMA systems may perform comparably to the CTT in titrating alloantibodies to Rh and Kell antigens. © 2012 American Association of Blood Banks.

  9. Down-titration of biologics for the treatment of rheumatoid arthritis: a systematic literature review.

    PubMed

    Lau, Chak Sing; Gibofsky, Allan; Damjanov, Nemanja; Lula, Sadiq; Marshall, Lisa; Jones, Heather; Emery, Paul

    2017-11-01

    Biologic therapies have improved the management of rheumatoid arthritis (RA) and the treat-to-target approach has resulted in many patients achieving remission. In the current treatment landscape, clinicians have begun considering dose reduction/tapering for their patients. Rheumatology guidelines in Asia, Europe, and the United States include down-titration of biologics but admit that the level of evidence is moderate. We conducted a systematic literature review to assess the published studies that evaluate down-titration of biologics in RA. The published literature was searched for studies that down-titrated the following biologics: abatacept, adalimumab, certolizumab, etanercept, golimumab, infliximab, rituximab, and tocilizumab. Eligible studies included randomized controlled trials (RCTs), non-RCTs, observational, and pharmacoeconomic studies. The outcomes of interest were (1) efficacy and health-related quality of life, (2) disease flares, and (3) impact on cost. Eleven full-text publications were identified; only three were RCTs. Study results suggest that dosing down may be an option in many patients who have achieved remission or low disease activity. However, some patients are likely to experience a disease flare. Across the studies, the definition of disease flare and the down-titration criteria were inconsistent, making it difficult to conclude which patients may be appropriate and when to attempt down-titration. Studies have evaluated the practice of dosing down biologic therapy in patients with RA; however, a relatively small number of RCTs have been published. Although down-titration may be an option for some patients in LDA or remission, additional RCTs are needed to provide guidance on this practice.

  10. Assessment of two theoretical methods to estimate potentiometric titration curves of peptides: comparison with experiment.

    PubMed

    Makowska, Joanna; Bagiñska, Katarzyna; Makowski, Mariusz; Jagielska, Anna; Liwo, Adam; Kasprzykowski, Franciszek; Chmurzyñski, Lech; Scheraga, Harold A

    2006-03-09

    We compared the ability of two theoretical methods of pH-dependent conformational calculations to reproduce experimental potentiometric titration curves of two models of peptides: Ac-K5-NHMe in 95% methanol (MeOH)/5% water mixture and Ac-XX(A)7OO-NH2 (XAO) (where X is diaminobutyric acid, A is alanine, and O is ornithine) in water, methanol (MeOH), and dimethyl sulfoxide (DMSO), respectively. The titration curve of the former was taken from the literature, and the curve of the latter was determined in this work. The first theoretical method involves a conformational search using the electrostatically driven Monte Carlo (EDMC) method with a low-cost energy function (ECEPP/3 plus the SRFOPT surface-solvation model, assumming that all titratable groups are uncharged) and subsequent reevaluation of the free energy at a given pH with the Poisson-Boltzmann equation, considering variable protonation states. In the second procedure, molecular dynamics (MD) simulations are run with the AMBER force field and the generalized Born model of electrostatic solvation, and the protonation states are sampled during constant-pH MD runs. In all three solvents, the first pKa of XAO is strongly downshifted compared to the value for the reference compounds (ethylamine and propylamine, respectively); the water and methanol curves have one, and the DMSO curve has two jumps characteristic of remarkable differences in the dissociation constants of acidic groups. The predicted titration curves of Ac-K5-NHMe are in good agreement with the experimental ones; better agreement is achieved with the MD-based method. The titration curves of XAO in methanol and DMSO, calculated using the MD-based approach, trace the shape of the experimental curves, reproducing the pH jump, while those calculated with the EDMC-based approach and the titration curve in water calculated using the MD-based approach have smooth shapes characteristic of the titration of weak multifunctional acids with small differences between the dissociation constants. Nevertheless, quantitative agreement between theoretically predicted and experimental titration curves is not achieved in all three solvents even with the MD-based approach, which is manifested by a smaller pH range of the calculated titration curves with respect to the experimental curves. The poorer agreement obtained for water than for the nonaqueous solvents suggests a significant role of specific solvation in water, which cannot be accounted for by the mean-field solvation models.

  11. Yoghurts with addition of selected vegetables: acidity, antioxidant properties and sensory quality.

    PubMed

    Najgebauer-Lejko, Dorota; Grega, Tadeusz; Tabaszewska, Małgorzata

    2014-01-01

    Yoghurt is a fermented milk of unique sensory, nutritive and dietetic value offered in a variety of types and in different flavours. Vegetables belong to the group of food products rich in antioxidant substances (e.g., vitamin C, carotenoids, tocopherols, polyphenols) which regular consumption lowers the risk of many diseases including cancers and cardiovascular disorders. The aim of the present work was to manufacture and assess the acidity, sensory quality and antioxidant capacity of yoghurts with addition of selected vegetables during 2-week refrigerated storage. The vegetable preparations (carrot, pumpkin, broccoli and red sweet pepper) were added to the cow's milk fermented using DVS type yoghurt culture after initial cooling to 15-20°C in the amount of 10% (w/w). The following analyses were performed: determination of pH, titratable acidity, antioxidant activity by ferric reducing antioxidant power (FRAP) and 2,2'-diphenyl-1-picrylhydrazyl (DPPH) method as well as sensory evaluation and were conducted after 1, 7 and 14 days of cold storage. The yoghurt supplementation with selected vegetables had no significant effect on the pH and titratable acidity level. The highest ability to scavenge DPPH radicals was stated for yoghurts with broccoli and red sweet pepper. The latter treatment gained the highest notes in sensory evaluation. All vegetable yoghurts were characterised by higher than the natural yoghurt FRAP values measured directly after production. However, the level of this parameter significantly decreased after storage. The red sweet pepper additive was the most beneficial regarding antioxidant properties and organoleptic acceptance of the studied yoghurts.

  12. Mesoporous Carbons With Self-Assembled High-Activity Surfaces (PREPRINT)

    DTIC Science & Technology

    2006-07-07

    temperature-programmed desorption, and potentiometric titrations . Journal of Colloid and Interface Science 2001; 240: 252–258. [40] Rotkin SV, Gogotsi Y...selected carbon samples were treated with nitric acid and the total acid site density determined by base titration [32-34 Boehm 1994; Boehm 2002; 32...washed thoroughly using distilled/deionized water, and dried in the oven. For the titration , 50 mg of HNO3-treated carbon powder was added to 20 ml

  13. High-Molecular Compounds (Selected Articles).

    DTIC Science & Technology

    1987-10-15

    us ions The method of potentiometric titration in dimethylformamide was used to study the structure of macro molecular chain of copolymers based on...macromolecular chain we used the method of potential metric titration . The objects of the study uere alpha chloroacrylic acid (KO)K) in monomer...homopolymer, and copolymer (with methylmethacrylate) form 131. I e d* r. I%0 I 0 12 # z Curves of potential metric titration of solutions of copolymers of KjAK

  14. The Thermodynamics of the Carbonate System in Seawater,

    DTIC Science & Technology

    1979-03-08

    ionization of water at various water by potentiometric titration . Deep-Sea Res. 17, temperatures from molal volume data. J. Soln. Chem. 737-750. 1... titration alkalinity, AT, givcn by not available at low salinities and molal volume cal- A, = [HCO/] + 2[CO2-] + [B(OH-] culations (MILLERO et al...used to characterize obtained by a computer titration improves, pH the parameters of the carbonate system in seawater. measurements should be made. This

  15. The Velocity of Sound in Sea Water at Zero Depth

    DTIC Science & Technology

    1952-06-11

    the Woods Hole Oceanographic Institution. Toward the end of this investigation a potentiometric titration with the Beckman automatic titratcr and a...Interferon eter as soon as received, and at Intervals throughout the investigation. Ch!orlnitie3 were determined by the Mohr method of AgNOi titration ...chlorinity of each of the solutions was actually determined by Mohr titration in the sar.? manner as the chiorinities of the original samples. The

  16. Process for Assessing the Stability of HAN (Hydroxylammonium Nitrate)-Based Liquid Propellants

    DTIC Science & Technology

    1989-02-09

    Scholz, Guidelines by Messrs. Riedel - de Haen for Titration according to the Karl Fischer Method ), 3. Auflage/3rd Edition 1982 /22/ JANDER; G. and... Potentiometric determination of the equivalence point is the most suitable method /15/. Time is saved by using automatically recording titration 33...propellant. The water content of liquid propellants on the basis of HAN according to Fig. 6 can be determined directly by Karl Fischer titration. This

  17. Cost-effectiveness of ezetimibe coadministration in statin-treated patients not at cholesterol goal: application to Germany, Spain and Norway.

    PubMed

    Cook, John R; Yin, Don; Alemao, Evo; Davies, Glenn; Krobot, Karl J; Veltri, Enrico; Lipka, Leslie; Badia, Xavier

    2004-01-01

    Despite the growing use of statins, many hypercholesterolaemic patients fail to reach their lipid goal and remain at elevated risk of coronary heart disease (CHD). Alternative treatment strategies, such as ezetimibe coadministration and statin titration, can help patients achieve greater lipid control, and thereby lower their CHD risk. But is it cost effective to more aggressively lower cholesterol levels across a broad range of current statin users? Using a decision-analytic model based on epidemiological and clinical trials data, we project the lifetime benefit and cost of alternative lipid-lowering treatment strategies for CHD and non-CHD diabetic patients in Germany, Spain and Norway. It is projected that from 40% to 76% of these patients who have failed to reach their lipid goal with their current statin treatment will be able to reach their goal with ezetimibe coadministration; this represents a gain of up to an additional absolute 14% who will be able to reach their goal compared with a 'titrate to goal' strategy where patients are titrated in order to reach their lipid goal (up to the maximum approved dose). For CHD patients, the estimated incremental cost-effectiveness ratio for ezetimibe coadministration is under Euro 18 000 per life-year gained (Euro/LYG) and 26 000 Euro/LYG compared with strategies based on the observed titration rates and the aggressive 'titrate to goal' strategy, respectively; for non-CHD diabetic patients, these ratios are under 26 000 Euro/LYG and 48 000 Euro/LYG for ezetimibe coadministration compared with the two titration strategies. Compared with statin titration, ezetimibe coadministration is projected to be cost effective in the populations and countries studied.

  18. Evaluation of synergistic effects of resynchronization therapy and a β-blocker up-titration strategy based on a predefined patient-management program: the RESTORE study.

    PubMed

    Palmisano, Pietro; Ammendola, Ernesto; D'Onofrio, Antonio; Accogli, Michele; Calò, Leonardo; Ruocco, Antonio; Rapacciuolo, Antonio; Del Giorno, Giuseppe; Bianchi, Valter; Malacrida, Maurizio; Valsecchi, Sergio; Gronda, Edoardo

    2015-01-01

    Prior studies have suggested that a substantial number of eligible heart failure (HF) patients fail to receive β-blocker therapy, or receive it at a suboptimal dose. The aim of this study is to assess the benefit of a predefined management program designed for β-blocker up-titration, evaluating the synergistic effect of cardiac resynchronization therapy (CRT) and β-blockers in a HF population. The Resynchronization Therapy and β-Blocker Titration (RESTORE) study is a prospective, case-control, multicenter cohort study designed to test the hypothesis that a β-blocker up-titration strategy based on a predefined management program maximizes the beneficial effect of CRT, increasing the number of patients reaching the target dose of β-blockers and improving their clinical outcome. All study patients receive an implantable defibrillator for CRT delivery in accordance with current guidelines. Enrollments started in December 2011 and are scheduled to end in December 2014. Approximately 250 consecutive patients will be prospectively enrolled in 6 Italian centers and followed up for 24 months after implantation. The primary endpoint is to demonstrate that CRT may allow titration of β-blockers until the optimal dose, or at least to the effective dose, in patients with HF. This study might provide important information about the benefit of a predefined management program for β-blocker up-titration in patients receiving CRT. Moreover, assessment of health-care utilization and the consumption of resources will allow estimating the potential utility of remote monitoring by means of an automated telemedicine system in facilitating the titration of β-blockers in comparison with a standard in-hospital approach. © 2015 Wiley Periodicals, Inc.

  19. Clinical Outcomes of Continuation of Metformin Titration Instructions with Electronic Prescribing.

    PubMed

    Delate, Thomas; Rader, Nathan; Rawlings, Julia E; Smith, Karen; Herner, Sheryl J

    2015-06-01

    Anecdotal evidence suggests that metformin titration instructions are not being updated and refill requests are approved without modification of the titration instructions such that the titration instructions is continued for patients newly initiated on metformin. This was a retrospective cohort analysis of adult patients who received newly initiated metformin pharmacotherapy. Patients were followed from their initial metformin purchase through two subsequent metformin refill purchases. Outcomes, including the 3-year incidence rate of patients with at least one set of continued titration instructions and proportions of patients with at least one gastrointestinal adverse effect (AE) and those with an elevated glucose measurement at follow-up, were assessed during the time period between patients' second and third metformin purchases. Analyses were performed comparing the exposure (i.e., patients with continued instructions) group to the control (i.e., patients without continued instructions) group. The exposure group had a higher mean age and chronic disease score but lower metformin starting dose than the control group (all p < 0.05). The 3-year incidence rate of patients with at least one continuation of titration instructions was 60.3 % (95 % CI 58.3-62.3). Gastrointestinal AEs were rare with equivalent proportions of patients in each group experiencing an event (p > 0.05). Control patients (48.7 % of patients with a measurement) were more likely to have had poorly controlled glucose than exposure patients (35.7 % of patients with a measurement) (p < 0.001). A high rate of continuation of titration instructions for patients newly initiated on metformin was observed; however, such continuation did not negatively affect clinical outcomes.

  20. Barriers to Beta-Blocker Use and Up-Titration Among Patients with Heart Failure with Reduced Ejection Fraction.

    PubMed

    Levitan, Emily B; Van Dyke, Melissa K; Loop, Matthew Shane; O'Beirne, Ronan; Safford, Monika M

    2017-12-01

    For patients with heart failure with reduced ejection fraction (HFrEF), guidelines recommend use of beta-blockers with gradual up-titration. However, many patients with HFrEF do not use beta-blockers and up-titration is rare. Our purpose was to identify and rank barriers to beta-blocker use and up-titration from the perspective of primary care physicians. We conducted 4 moderated, structured group discussions among 19 primary care physicians using the nominal group technique; 16 participants also completed a survey. Participants generated lists of barriers to beta-blocker use and up-titration among patients with HFrEF. Each participant had six votes with three votes assigned to the item ranked most important, two to the second most important item, and one to the third most important item. Investigators characterized items into themes. The percentage of available votes was calculated for each theme. Fifteen of 16 participating primary care physicians who completed the survey reported that management of beta-blockers was their responsibility. Treatment/side effects, particularly hypotension, were identified as the most important barrier for beta-blocker use (72% of available votes) followed by polypharmacy (11%), healthcare system barriers (10%), and comorbidities (6%). Barriers to up-titration included treatment/side effects (49% of available votes), patient communication/buy-in (21%), polypharmacy (13%), and healthcare system barriers (8%). Many barriers to guideline concordant use of beta-blockers among patients with HFrEF identified by primary care providers are not readily modifiable. Addressing these barriers may require development, testing, and dissemination of protocols for beta-blocker initiation and up-titration that are safe and appropriate in primary care.

  1. Predicting prolonged dose titration in patients starting warfarin.

    PubMed

    Finkelman, Brian S; French, Benjamin; Bershaw, Luanne; Brensinger, Colleen M; Streiff, Michael B; Epstein, Andrew E; Kimmel, Stephen E

    2016-11-01

    Patients initiating warfarin therapy generally experience a dose-titration period of weeks to months, during which time they are at higher risk of both thromboembolic and bleeding events. Accurate prediction of prolonged dose titration could help clinicians determine which patients might be better treated by alternative anticoagulants that, while more costly, do not require dose titration. A prediction model was derived in a prospective cohort of patients starting warfarin (n = 390), using Cox regression, and validated in an external cohort (n = 663) from a later time period. Prolonged dose titration was defined as a dose-titration period >12 weeks. Predictor variables were selected using a modified best subsets algorithm, using leave-one-out cross-validation to reduce overfitting. The final model had five variables: warfarin indication, insurance status, number of doctor's visits in the previous year, smoking status, and heart failure. The area under the ROC curve (AUC) in the derivation cohort was 0.66 (95%CI 0.60, 0.74) using leave-one-out cross-validation, but only 0.59 (95%CI 0.54, 0.64) in the external validation cohort, and varied across clinics. Including genetic factors in the model did not improve the area under the ROC curve (0.59; 95%CI 0.54, 0.65). Relative utility curves indicated that the model was unlikely to provide a clinically meaningful benefit compared with no prediction. Our results suggest that prolonged dose titration cannot be accurately predicted in warfarin patients using traditional clinical, social, and genetic predictors, and that accurate prediction will need to accommodate heterogeneities across clinical sites and over time. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Entire-Dataset Analysis of NMR Fast-Exchange Titration Spectra: A Mg2+ Titration Analysis for HIV-1 Ribonuclease H Domain.

    PubMed

    Karki, Ichhuk; Christen, Martin T; Spiriti, Justin; Slack, Ryan L; Oda, Masayuki; Kanaori, Kenji; Zuckerman, Daniel M; Ishima, Rieko

    2016-12-15

    This article communicates our study to elucidate the molecular determinants of weak Mg 2+ interaction with the ribonuclease H (RNH) domain of HIV-1 reverse transcriptase in solution. As the interaction is weak (a ligand-dissociation constant >1 mM), nonspecific Mg 2+ interaction with the protein or interaction of the protein with other solutes that are present in the buffer solution can confound the observed Mg 2+ -titration data. To investigate these indirect effects, we monitored changes in the chemical shifts of backbone amides of RNH by recording NMR 1 H- 15 N heteronuclear single-quantum coherence spectra upon titration of Mg 2+ into an RNH solution. We performed the titration under three different conditions: (1) in the absence of NaCl, (2) in the presence of 50 mM NaCl, and (3) at a constant 160 mM Cl - concentration. Careful analysis of these three sets of titration data, along with molecular dynamics simulation data of RNH with Na + and Cl - ions, demonstrates two characteristic phenomena distinct from the specific Mg 2+ interaction with the active site: (1) weak interaction of Mg 2+ , as a salt, with the substrate-handle region of the protein and (2) overall apparent lower Mg 2+ affinity in the absence of NaCl compared to that in the presence of 50 mM NaCl. A possible explanation may be that the titrated MgCl 2 is consumed as a salt and interacts with RNH in the absence of NaCl. In addition, our data suggest that Na + increases the kinetic rate of the specific Mg 2+ interaction at the active site of RNH. Taken together, our study provides biophysical insight into the mechanism of weak metal interaction on a protein.

  3. Improved methylene blue two-phase titration method for determining cationic surfactant concentration in high-salinity brine.

    PubMed

    Cui, Leyu; Puerto, Maura; López-Salinas, José L; Biswal, Sibani L; Hirasaki, George J

    2014-11-18

    The methylene blue (MB) two-phase titration method is a rapid and efficient method for determining the concentrations of anionic surfactants. The point at which the aqueous and chloroform phases appear equally blue is called Epton's end point. However, many inorganic anions, e.g., Cl(-), NO3(-), Br(-), and I(-), can form ion pairs with MB(+) and interfere with Epton's end point, resulting in the failure of the MB two-phase titration in high-salinity brine. Here we present a method to extend the MB two-phase titration method for determining the concentration of various cationic surfactants in both deionized water and high-salinity brine (22% total dissolved solid). A colorless end point, at which the blue color is completely transferred from the aqueous phase to the chloroform phase, is proposed as titration end point. Light absorbance at the characteristic wavelength of MB is measured using a spectrophotometer. When the absorbance falls below a threshold value of 0.04, the aqueous phase is considered colorless, indicating that the end point has been reached. By using this improved method, the overall error for the titration of a permanent cationic surfactant, e.g., dodecyltrimethylammonium bromide, in deionized (DI) water and high-salinity brine is 1.274% and 1.322% with limits of detection (LOD) of 0.149 and 0.215 mM, respectively. Compared to the traditional acid-base titration method, the error of this improved method for a switchable cationic surfactant, e.g., tertiary amine surfactant (Ethomeen C12), is 2.22% in DI water and 0.106% with LOD of 0.369 and 0.439 mM, respectively.

  4. Barriers to and enablers of insulin self-titration in adults with Type 2 diabetes: a qualitative study.

    PubMed

    McBain, H; Begum, S; Rahman, S; Mulligan, K

    2017-02-01

    To identify the barriers to and enablers of effective insulin self-titration in people with Type 2 diabetes. A qualitative semi-structured interview approach was used. Questions were structured according to the Theoretical Domains Framework, which outlines 14 domains that can act as barriers to and enablers of changing behaviour. Interviews were audio-recorded and transcribed verbatim. The data were coded according to the 14 domains, belief statements were created within each domain, and a frequency count of the most reported barriers and enablers was then carried out. Analyses were conducted by two researchers, and discrepancies agreed with a third researcher. A total of 18 adults with Type 2 diabetes took part in an interview. The majority were of South-Asian ethnicity (n = 8) and were men (n = 12). Their mean age was 61 years old. The mean duration of diabetes was 16 years and time on insulin 9 years. Inter-rater reliability for each of the domains varied (29-100%). The most frequently reported domains were Social Influence and Beliefs about Consequences; the least frequently reported were Optimism and Reinforcement. Interviewees reported receiving support to self-titrate from a range of sources. Self-titrating was perceived to have a range of both positive and negative consequences, as was not titrating. The findings highlight that those interviewed experienced a range of barriers and enablers when attempting to self-titrate. Improved education and training when initiating insulin treatment among adults with Type 2 diabetes, and throughout their journey on insulin therapy could help identify and address these barriers in order to optimize self-titration. © 2016 Diabetes UK.

  5. Labeling Cells with Silver/Dendrimer Nanocomposites

    DTIC Science & Technology

    2005-01-01

    used in further studies without additional purification. Potentiometric titrations were performed manually, under nitrogen atmosphere, at room...transmits light between 465 and 485 nm. Results and Discussion Figure IA presents potentiometric titration curves of Ag+-PAMAM_E5.NH 2 systems mixed at 15:1... Potentiometric titration curves of PAMAM_E5.NH 2 (circles) Ag+-PAMAME5.NH 2 30:1 (squares) and Ag+-PAMAME5.NH2 45:1 systems (triangles). B - UV-vis spectra of UV

  6. Molecular Weight Measurement of Biobased Furan Polyamides via Non-Aqueous Potentiometric Titration

    DTIC Science & Technology

    2013-06-01

    electromagnetic fields, all titrations were completed in a chemical hood, which acted as a Faraday cage (a shield used to blocks external static and...while using DMF as a solvent. Additionally, no Faraday cage was used in the experimental setup, so the titrations were conducted inside the chemical...monomer was becoming more soluble in glacial acetic acid and the amount of chlorobenzene had less of an effect on the solution properties (i.e

  7. The benefit of HH during the CPAP titration in the cool sleeping environment.

    PubMed

    Li, Yayong; Wang, Yina

    2016-12-01

    Upper airway symptom associated with continuous positive airway pressure (CPAP) treatment is an important factor influencing CPAP adherence. There are conflicting data on the effect of a heated humidifier (HH) during CPAP titration for patients with obstructive sleep apnea hypopnea syndrome (OSAHS). This study investigated the effects of HH during CPAP titration in the cool sleeping environment. Forty newly diagnosed OSAHS patients who received CPAP titration in the cool sleeping environment were randomly assigned to HH and non-HH groups. A questionnaire was used to evaluate upper airway symptoms, satisfaction with initial CPAP treatment, and willingness to further use CPAP. Some therapy parameters including leak, apnea hypopnea index (AHI) reduction, and optimal CPAP pressure level were analyzed. We compared these subjective and objective data between the two groups. In subjective sensation, the use of HH can alleviate upper airway symptoms associated with CPAP titration (P < 0.001). The HH group has benefit in satisfaction with initial CPAP treatment (P < 0.001) and further willingness to use CPAP (P < 0.01), although there were no significant differences in leak, AHI reduction, and optimal CPAP pressure between the two groups. The use of HH is recommended during CPAP titration in the cool sleeping environment because of its benefit in the treatment of upper airway symptoms associated with CPAP therapy and improvement of the CPAP acceptance.

  8. Modeling the acid-base surface chemistry of montmorillonite.

    PubMed

    Bourg, Ian C; Sposito, Garrison; Bourg, Alain C M

    2007-08-15

    Proton uptake on montmorillonite edge surfaces can control pore water pH, solute adsorption, dissolution kinetics and clay colloid behavior in engineered clay barriers and natural weathering environments. Knowledge of proton uptake reactions, however, is currently limited by strong discrepancies between reported montmorillonite titration data sets and by conflicting estimates of edge structure, reactivity and electrostatics. In the present study, we show that the apparent discrepancy between titration data sets results in large part from the widespread use of an erroneous assumption of zero specific net proton surface charge at the onset of titration. Using a novel simulation scheme involving a surface chemistry model to simulate both pretreatment and titration, we find that montmorillonite edge surface chemistry models that account for the "spillover" of electrostatic potential from basal onto edge surfaces and for the stabilization of deprotonated Al-Si bridging sites through bond-length relaxation at the edge surface can reproduce key features of the best available experimental titration data (the influence of pretreatment conditions on experimental results, the absence of a point of zero salt effect, buffer capacity in the acidic pH range). However, no combination of current models of edge surface structure, reactivity and electrostatics can quantitatively predict, without fitted parameters, the experimental titration data over the entire range of pH (4.5 to 9) and ionic strength (0.001 to 0.5 mol dm(-3)) covered by available data.

  9. Switching to aripiprazole in outpatients with schizophrenia experiencing insufficient efficacy and/or safety/tolerability issues with risperidone: a randomized, multicentre, open-label study.

    PubMed

    Ryckmans, V; Kahn, J P; Modell, S; Werner, C; McQuade, R D; Kerselaers, W; Lissens, J; Sanchez, R

    2009-05-01

    This study evaluated the safety/tolerability and effectiveness of aripiprazole titrated-dose versus fixed-dose switching strategies from risperidone in patients with schizophrenia experiencing insufficient efficacy and/or safety/tolerability issues. Patients were randomized to an aripiprazole titrated-dose (starting dose 5 mg/day) or fixed-dose (dose 15 mg/day) switching strategy with risperidone down-tapering. Primary endpoint was rate of discontinuation due to adverse events (AEs) during the 12-week study. Secondary endpoints included positive and negative syndrome scale (PANSS), clinical global impressions - improvement of illness scale (CGI-I), preference of medication (POM), subjective well-being under neuroleptics (SWN-K) and GEOPTE (Grupo Español para la Optimización del Tratamiento de la Esquizofrenia) scales. Rates of discontinuations due to AEs were similar between titrated-dose and fixed-dose strategies (3.5% vs. 5.0%; p=0.448). Improvements in mean PANSS total scores were similar between aripiprazole titrated-dose and fixed-dose strategies (-14.8 vs. -17.2; LOCF), as were mean CGI-I scores (2.9 vs. 2.8; p=0.425; LOCF) and SWN-K scores (+8.6 vs.+10.3; OC,+7.8 vs.+9.8; LOCF). Switching can be effectively and safely achieved through a titrated-dose or fixed-dose switching strategy for aripiprazole, with down-titration of risperidone.

  10. A digital image-based method for determining of total acidity in red wines using acid-base titration without indicator.

    PubMed

    Tôrres, Adamastor Rodrigues; Lyra, Wellington da Silva; de Andrade, Stéfani Iury Evangelista; Andrade, Renato Allan Navarro; da Silva, Edvan Cirino; Araújo, Mário César Ugulino; Gaião, Edvaldo da Nóbrega

    2011-05-15

    This work proposes the use of digital image-based method for determination of total acidity in red wines by means of acid-base titration without using an external indicator or any pre-treatment of the sample. Digital images present the colour of the emergent radiation which is complementary to the radiation absorbed by anthocyanines present in wines. Anthocyanines change colour depending on the pH of the medium, and from the variation of colour in the images obtained during titration, the end point can be localized with accuracy and precision. RGB-based values were employed to build titration curves, and end points were localized by second derivative curves. The official method recommends potentiometric titration with a NaOH standard solution, and sample dilution until the pH reaches 8.2-8.4. In order to illustrate the feasibility of the proposed method, titrations of ten red wines were carried out. Results were compared with the reference method, and no statistically significant difference was observed between the results by applying the paired t-test at the 95% confidence level. The proposed method yielded more precise results than the official method. This is due to the trivariate nature of the measurements (RGB), associated with digital images. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. End-point detection in potentiometric titration by continuous wavelet transform.

    PubMed

    Jakubowska, Małgorzata; Baś, Bogusław; Kubiak, Władysław W

    2009-10-15

    The aim of this work was construction of the new wavelet function and verification that a continuous wavelet transform with a specially defined dedicated mother wavelet is a useful tool for precise detection of end-point in a potentiometric titration. The proposed algorithm does not require any initial information about the nature or the type of analyte and/or the shape of the titration curve. The signal imperfection, as well as random noise or spikes has no influence on the operation of the procedure. The optimization of the new algorithm was done using simulated curves and next experimental data were considered. In the case of well-shaped and noise-free titration data, the proposed method gives the same accuracy and precision as commonly used algorithms. But, in the case of noisy or badly shaped curves, the presented approach works good (relative error mainly below 2% and coefficients of variability below 5%) while traditional procedures fail. Therefore, the proposed algorithm may be useful in interpretation of the experimental data and also in automation of the typical titration analysis, specially in the case when random noise interfere with analytical signal.

  12. Potentiometric Titrations for Measuring the Capacitance of Colloidal Photodoped ZnO Nanocrystals.

    PubMed

    Brozek, Carl K; Hartstein, Kimberly H; Gamelin, Daniel R

    2016-08-24

    Colloidal semiconductor nanocrystals offer a unique opportunity to bridge molecular and bulk semiconductor redox phenomena. Here, potentiometric titration is demonstrated as a method for quantifying the Fermi levels and charging potentials of free-standing colloidal n-type ZnO nanocrystals possessing between 0 and 20 conduction-band electrons per nanocrystal, corresponding to carrier densities between 0 and 1.2 × 10(20) cm(-3). Potentiometric titration of colloidal semiconductor nanocrystals has not been described previously, and little precedent exists for analogous potentiometric titration of any soluble reductants involving so many electrons. Linear changes in Fermi level vs charge-carrier density are observed for each ensemble of nanocrystals, with slopes that depend on the nanocrystal size. Analysis indicates that the ensemble nanocrystal capacitance is governed by classical surface electrical double layers, showing no evidence of quantum contributions. Systematic shifts in the Fermi level are also observed with specific changes in the identity of the charge-compensating countercation. As a simple and contactless alternative to more common thin-film-based voltammetric techniques, potentiometric titration offers a powerful new approach for quantifying the redox properties of colloidal semiconductor nanocrystals.

  13. Origin of two time-scale regimes in potentiometric titration of metal oxides. A replica kinetic Monte Carlo study.

    PubMed

    Zarzycki, Piotr; Rosso, Kevin M

    2009-06-16

    Replica kinetic Monte Carlo simulations were used to study the characteristic time scales of potentiometric titration of the metal oxides and (oxy)hydroxides. The effect of surface heterogeneity and surface transformation on the titration kinetics were also examined. Two characteristic relaxation times are often observed experimentally, with the trailing slower part attributed to surface nonuniformity, porosity, polymerization, amorphization, and other dynamic surface processes induced by unbalanced surface charge. However, our simulations show that these two characteristic relaxation times are intrinsic to the proton-binding reaction for energetically homogeneous surfaces, and therefore surface heterogeneity or transformation does not necessarily need to be invoked. However, all such second-order surface processes are found to intensify the separation and distinction of the two kinetic regimes. The effect of surface energetic-topographic nonuniformity, as well dynamic surface transformation, interface roughening/smoothing were described in a statistical fashion. Furthermore, our simulations show that a shift in the point-of-zero charge is expected from increased titration speed, and the pH-dependence of the titration measurement error is in excellent agreement with experimental studies.

  14. Trace analysis of acids and bases by conductometric titration with multiparametric non-linear regression.

    PubMed

    Coelho, Lúcia H G; Gutz, Ivano G R

    2006-03-15

    A chemometric method for analysis of conductometric titration data was introduced to extend its applicability to lower concentrations and more complex acid-base systems. Auxiliary pH measurements were made during the titration to assist the calculation of the distribution of protonable species on base of known or guessed equilibrium constants. Conductivity values of each ionized or ionizable species possibly present in the sample were introduced in a general equation where the only unknown parameters were the total concentrations of (conjugated) bases and of strong electrolytes not involved in acid-base equilibria. All these concentrations were adjusted by a multiparametric nonlinear regression (NLR) method, based on the Levenberg-Marquardt algorithm. This first conductometric titration method with NLR analysis (CT-NLR) was successfully applied to simulated conductometric titration data and to synthetic samples with multiple components at concentrations as low as those found in rainwater (approximately 10 micromol L(-1)). It was possible to resolve and quantify mixtures containing a strong acid, formic acid, acetic acid, ammonium ion, bicarbonate and inert electrolyte with accuracy of 5% or better.

  15. Use of the sulfide mineral pyrite as electrochemical sensor in non-aqueous solutions: potentiometric titration of weak acids in acetonitrile, propionitrile and benzonitrile.

    PubMed

    Mihajlović, Ljiljana; Nikolić-Mandić, Snezana; Vukanović, Branislav; Mihajlović, Randel

    2009-03-01

    Natural monocrystalline pyrite as a new indicator electrode for the potentiometric titration of weak acids in acetonitrile, propionitrile and benzonitrile was studied. The investigated electrode showed a linear dynamic response for p-toluenesulfonic acid concentrations in the range from 0.1 to 0.001 M, with a Nernstian slope of 74 mV per decade. Sodium methylate, potassium hydroxide and tetrabutylammonium hydroxide (TBAH) proved to be very suitable titrating agent for this titration. The response time was less than (11 s) and the lifetime of the electrode is long. The advantages of the electrode are log-term stability, fast response, and reproducibility, while the sensor is easy to prepare and of low cost.

  16. Determination of arsenate and organic arsenic via potentiometric titration of its heteropoly anions.

    PubMed

    Metelka, R; Slavíková, S; Vytras, K

    2002-08-16

    Determination of arsenate based on its conversion to molybdoarsenate heteropoly anions followed by potentiometric titration is described. The titration is realized on the ion-pairing principle using cetylpyridinium chloride (or an analogous titrant containing a lipophilic cation), and is monitored by a carbon paste electrode, although other liquid-polymeric membrane-based electrodes can also be used. Calibration plots of the titrant end-point consumption versus concentration of arsenic were constructed and used to evaluate the content of arsenic in aqueous samples. The method could be applied in the analyses of samples with quite low arsenic content (amounts approximately 10 mug As in 50 cm(3) could be titrated). Organic arsenic was determined analogously after the Schöniger combustion of the sample and conversion of its arsenic to arsenate.

  17. Ln3+-Catalyzed Alcoholysis of Organophosphates: New Methodology for the Catalytic Transformation of Phosphorus Pesticides and CW Agents

    DTIC Science & Technology

    2007-03-14

    1770. 9. Graham T. T. Gibson, Mark F. Mohamed, Alexei A. Neverov and R. S. Brown*, “ Potentiometric titration of metal ions in ethanol.” Inorganic...81, 495-504. 2 . Graham T. T. Gibson, Mark F. Mohamed, Alexei A. Neverov and R. S. Brown*, “ Potentiometric titration of metal ions in ethanol...necessary to understand the determination of pH in these anhydrous solvents, and then to undertake detailed studies of titration of metal

  18. Advanced titration to treat a floppy epiglottis in selective upper airway stimulation.

    PubMed

    Heiser, Clemens

    2016-09-01

    The following report presents a case of a patient with high residual apnea-hypopnea index at 6 months following implantation of an upper airway stimulation device who improved significantly after advanced titration via drug-induced sedated endoscopy by changing the electrode configuration for stimulation from bipolar to monopolar. This case demonstrates the utility of postsurgical advanced titration to optimize programming settings for improved clinical outcomes. Laryngoscope, 126:S22-S24, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  19. Evaluation of Expedient Decontamination Options with Activated Peroxide-based Liquid Sporicides

    DTIC Science & Technology

    2013-02-05

    H2O2 (6% immediately post mixing) was verified by potassium permanganate titration (see Appendix B, DTRL MOP #3177) and then monitored throughout testing...H2O2 Concentration in AHP The concentration of H2O2 in the AHP solution was verified by analyzing with the potassium permanganate (KMnO4) titration...Concentration of H2O2 in the working decontamination solution was measured via permanganate titration in 24 samples of AHP taken from the backpack sprayer

  20. Report of a patient chewing fentanyl patches who was titrated onto methadone

    PubMed Central

    Dale, Eric; Ashby, Fleur; Seelam, Kalyan

    2009-01-01

    This case report discusses the clinical presentation and management of a patient presenting to substance misuse services reporting chewing fentanyl patches in addition to wearing them transdermally. The patient was successfully titrated onto methadone 30 mg. Only one previously reported case of an individual chewing fentanyl patches was found in the literature; no case reports were found where treatment involved titrating the patient onto methadone. The pharmacology and illicit use of fentanyl are also considered. PMID:22114625

  1. Calorimetry Studies of Ammonia, Nitric Acid, and Ammonium Nitrate

    DTIC Science & Technology

    1979-10-01

    50 microns of Hg. Glass ampules containing NH4NO3were filled in the dry box and then flame-sealed under a nitrogen atmosphere. A Karl - Fischer titration...was standardized by potentiometric titration against standard 1 N HCI, For calorimetric measurements, samples were transferred by syringe into weighed... potentiometric titration against standard 1 N NaOH, was 99.6 + 0.2 wt% HNO3. As a measure of tte extent of reaction with the wall oTthe3* calorimeter, HNO3

  2. Amperometric, Bipotentiometric, and Coulometric Titration.

    ERIC Educational Resources Information Center

    Stock, John T.

    1980-01-01

    Discusses recent review articles in various kinds of titration. Also discusses new research in apparatus and methodology, acid-base reactions, precipitation and complexing reactions, oxidation-reduction reactions, and nomenclature. Cites 338 references. (CS)

  3. Insulin degludec/insulin aspart once daily in Type 2 diabetes: a comparison of simple or stepwise titration algorithms (BOOST® : SIMPLE USE).

    PubMed

    Park, S W; Bebakar, W M W; Hernandez, P G; Macura, S; Hersløv, M L; de la Rosa, R

    2017-02-01

    To compare the efficacy and safety of two titration algorithms for insulin degludec/insulin aspart (IDegAsp) administered once daily with metformin in participants with insulin-naïve Type 2 diabetes mellitus. This open-label, parallel-group, 26-week, multicentre, treat-to-target trial, randomly allocated participants (1:1) to two titration arms. The Simple algorithm titrated IDegAsp twice weekly based on a single pre-breakfast self-monitored plasma glucose (SMPG) measurement. The Stepwise algorithm titrated IDegAsp once weekly based on the lowest of three consecutive pre-breakfast SMPG measurements. In both groups, IDegAsp once daily was titrated to pre-breakfast plasma glucose values of 4.0-5.0 mmol/l. Primary endpoint was change from baseline in HbA 1c (%) after 26 weeks. Change in HbA 1c at Week 26 was IDegAsp Simple -14.6 mmol/mol (-1.3%) (to 52.4 mmol/mol; 6.9%) and IDegAsp Stepwise -11.9 mmol/mol (-1.1%) (to 54.7 mmol/mol; 7.2%). The estimated between-group treatment difference was -1.97 mmol/mol [95% confidence interval (CI) -4.1, 0.2] (-0.2%, 95% CI -0.4, 0.02), confirming the non-inferiority of IDegAsp Simple to IDegAsp Stepwise (non-inferiority limit of ≤ 0.4%). Mean reduction in fasting plasma glucose and 8-point SMPG profiles were similar between groups. Rates of confirmed hypoglycaemia were lower for IDegAsp Stepwise [2.1 per patient years of exposure (PYE)] vs. IDegAsp Simple (3.3 PYE) (estimated rate ratio IDegAsp Simple /IDegAsp Stepwise 1.8; 95% CI 1.1, 2.9). Nocturnal hypoglycaemia rates were similar between groups. No severe hypoglycaemic events were reported. In participants with insulin-naïve Type 2 diabetes mellitus, the IDegAsp Simple titration algorithm improved HbA 1c levels as effectively as a Stepwise titration algorithm. Hypoglycaemia rates were lower in the Stepwise arm. © 2016 The Authors. Diabetic Medicine published by John Wiley & Sons Ltd on behalf of Diabetes UK.

  4. Going Beyond, Going Further: Knives, Forks, and Beer Cans as Potentiometric Sensors.

    ERIC Educational Resources Information Center

    Selig, Walter S.

    1985-01-01

    Background information, materials needed, and procedures used are provided for potentiometric fluoride, halide, orthophosphate, and sulfate titrations. Typical results obtained are also provided for each type of titration. (JN)

  5. A Titration Technique for Demonstrating a Magma Replenishment Model.

    ERIC Educational Resources Information Center

    Hodder, A. P. W.

    1983-01-01

    Conductiometric titrations can be used to simulate subduction-setting volcanism. Suggestions are made as to the use of this technique in teaching volcanic mechanisms and geochemical indications of tectonic settings. (JN)

  6. Three different up-titration regimens of ponesimod, an S1P1 receptor modulator, in healthy subjects.

    PubMed

    Scherz, Michael W; Brossard, Patrick; D'Ambrosio, Daniele; Ipek, Murat; Dingemanse, Jasper

    2015-06-01

    Ponesimod is a selective S1P1 receptor modulator, and induces dose-dependent reduction of circulating lymphocytes upon oral dosing. Previous studies showed that single doses up to 75 mg or multiple doses up to 40 mg once daily are well tolerated, and heart rate (HR) reduction and atrio-ventricular conduction delays upon treatment initiation are reduced by gradual up-titration to the maintenance dose. This single-center, open-label, randomized, multiple-dose, 3-treatment, 3-way crossover study compared the tolerability, safety, pharmacokinetics, cardiodynamics, and effects on lymphocytes of 3 different up-titration regimens of ponesimod in healthy male and female subjects. Up-titration regimens comprised escalating periods of b.i.d. dosing (2.5 or 5 mg) and q.d. dosing (10 or 20 mg or both). After the third up-titration period a variable-duration washout period of 1-3 days was followed by re-challenge with a single 20-mg dose of ponesimod. Adverse events were transient and mild to moderate in intensity, not different between regimens. HR decrease after the first dose was greater than after all subsequent doses, including up-titration doses. Little or no HR change was observed with morning doses of b.i.d. regimens, suggesting that 2.5 and 5 mg b.i.d. are sufficient to sustain cardiac desensitization for the 12-hours dosing interval. © 2015, The American College of Clinical Pharmacology.

  7. Estimating iron and aluminum content of acid mine discharge from a north-central Pennsylvania coal field by use of acidity titration curves

    USGS Publications Warehouse

    Ott, A.N.

    1986-01-01

    Determination of acidity provides a value that denotes the quantitative capacity of the sample water to neutralize a strong base to a particular pH. However, much additional information can be obtained from this determination if a titration curve is constructed from recorded data of titrant increments and their corresponding pH values. The curve can be used to identify buffer capabilities, the acidity with respect to any pH value within the curve limit, and, in the case of acid mine drainage from north-central Pennsylvania, the identification and estimation of the concentration of dissolved ferrous iron, ferric iron, and aluminum. Through use of titration curves, a relationship was observed for the acid mine drainage between: (1) the titratable acidity (as milligrams per liter calcium carbonate) to pH 4.0 and the concentration of dissolved ferric iron; and (2) the titratable acidity (as milligrams per liter calcium carbonate) from pH 4.0 to 5.0 and the concentration of dissolved aluminum. The presence of dissolved ferrous iron can be detected by the buffering effect exhibited in the area between pH 5.5 to 7.5. The concentration of ferrous iron is estimated by difference between the concentrations of ferric iron in an oxidized and unoxidized sample. Interferences in any of the titrations from manganese, magnesium, and aluminate, appear to be negligible within the pH range of interest.

  8. Assessment of two theoretical methods to estimate potentiometrictitration curves of peptides: comparison with experiment

    PubMed Central

    Makowska, Joanna; Bagiñska, Katarzyna; Makowski, Mariusz; Jagielska, Anna; Liwo, Adam; Kasprzykowski, Franciszek; Chmurzyñski, Lech; Scheraga, Harold A.

    2008-01-01

    We compared the ability of two theoretical methods of pH-dependent conformational calculations to reproduce experimental potentiometric-titration curves of two models of peptides: Ac-K5-NHMe in 95% methanol (MeOH)/5% water mixture and Ac-XX(A)7OO-NH2 (XAO) (where X is diaminobutyric acid, A is alanine, and O is ornithine) in water, methanol (MeOH) and dimethylsulfoxide (DMSO), respectively. The titration curve of the former was taken from the literature, and the curve of the latter was determined in this work. The first theoretical method involves a conformational search using the Electrostatically Driven Monte Carlo (EDMC) method with a low-cost energy function (ECEPP/3 plus the SRFOPT surface-solvation model, assumming that all titratable groups are uncharged) and subsequent reevaluation of the free energy at a given pH with the Poisson-Boltzmann equation, considering variable protonation states. In the second procedure, MD simulations are run with the AMBER force field and the Generalized-Born model of electrostatic solvation, and the protonation states are sampled during constant-pH MD runs. In all three solvents, the first pKa of XAO is strongly downshifted compared to the value for the reference compounds (ethyl amine and propyl amine, respectively); the water and methanol curves have one, and the DMSO curve has two jumps characteristic of remarkable differences in the dissociation constants of acidic groups. The predicted titration curves of Ac-K5-NHMe are in good agreement with the experimental ones; better agreement is achieved with the MD-based method. The titration curves of XAO in methanol and DMSO, calculated using the MD-based approach, trace the shape of the experimental curves, reproducing the pH jump, while those calculated with the EDMC-based approach, and the titration curve in water calculated using the MD-based approach, have smooth shapes characteristic of the titration of weak multifunctional acids with small differences between the dissociation constants. Nevertheless, quantitative agreement between theoretically predicted and experimental titration curves is not achieved in all three solvents even with the MD-based approach which is manifested by a smaller pH range of the calculated titration curves with respect to the experimental curves. The poorer agreement obtained for water than for the non-aqueous solvents suggests a significant role of specific solvation in water, which cannot be accounted for by the mean-field solvation models. PMID:16509748

  9. Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report.

    PubMed

    Morgenthaler, Timothy I; Aurora, R Nisha; Brown, Terry; Zak, Rochelle; Alessi, Cathy; Boehlecke, Brian; Chesson, Andrew L; Friedman, Leah; Kapur, Vishesh; Maganti, Rama; Owens, Judith; Pancer, Jeffrey; Swick, Todd J

    2008-01-01

    These practice parameters are an update of the previously published recommendations regarding the use of autotitrating positive airway pressure (APAP) devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. Continuous positive airway pressure (CPAP) at an effective setting verified by attended polysomnography is a standard treatment for obstructive sleep apnea (OSA). APAP devices change the treatment pressure based on feedback from various patient measures such as airflow, pressure fluctuations, or measures of airway resistance. These devices may aid in the pressure titration process, address possible changes in pressure requirements throughout a given night and from night to night, aid in treatment of OSA when attended CPAP titration has not or cannot be accomplished, or improve patient comfort. A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine has reviewed the literature published since the 2002 practice parameter on the use of APAP. Current recommendations follow: (1) APAP devices are not recommended to diagnose OSA; (2) patients with congestive heart failure, patients with significant lung disease such as chronic obstructive pulmonary disease; patients expected to have nocturnal arterial oxyhemoglobin desaturation due to conditions other than OSA (e.g., obesity hypoventilation syndrome); patients who do not snore (either naturally or as a result of palate surgery); and patients who have central sleep apnea syndromes are not currently candidates for APAP titration or treatment; (3) APAP devices are not currently recommended for split-night titration; (4) certain APAP devices may be used during attended titration with polysomnography to identify a single pressure for use with standard CPAP for treatment of moderate to severe OSA; (5) certain APAP devices may be initiated and used in the self-adjusting mode for unattended treatment of patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (6) certain APAP devices may be used in an unattended way to determine a fixed CPAP treatment pressure for patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (7) patients being treated with fixed CPAP on the basis of APAP titration or being treated with APAP must have close clinical follow-up to determine treatment effectiveness and safety; and (8) a reevaluation and, if necessary, a standard attended CPAP titration should be performed if symptoms do not resolve or the APAP treatment otherwise appears to lack efficacy.

  10. Development and validation of a simplified titration method for monitoring volatile fatty acids in anaerobic digestion.

    PubMed

    Sun, Hao; Guo, Jianbin; Wu, Shubiao; Liu, Fang; Dong, Renjie

    2017-09-01

    The volatile fatty acids (VFAs) concentration has been considered as one of the most sensitive process performance indicators in anaerobic digestion (AD) process. However, the accurate determination of VFAs concentration in AD processes normally requires advanced equipment and complex pretreatment procedures. A simplified method with fewer sample pretreatment procedures and improved accuracy is greatly needed, particularly for on-site application. This report outlines improvements to the Nordmann method, one of the most popular titrations used for VFA monitoring. The influence of ion and solid interfering subsystems in titrated samples on results accuracy was discussed. The total solid content in titrated samples was the main factor affecting accuracy in VFA monitoring. Moreover, a high linear correlation was established between the total solids contents and VFA measurement differences between the traditional Nordmann equation and gas chromatography (GC). Accordingly, a simplified titration method was developed and validated using a semi-continuous experiment of chicken manure anaerobic digestion with various organic loading rates. The good fitting of the results obtained by this method in comparison with GC results strongly supported the potential application of this method to VFA monitoring. Copyright © 2017. Published by Elsevier Ltd.

  11. On the acid-base properties of humic acid in soil.

    PubMed

    Cooke, James D; Hamilton-Taylor, John; Tipping, Edward

    2007-01-15

    Humic acid was isolated from three contrasting organic-rich soils and acid-base titrations performed over a range of ionic strengths. Results obtained were unlike most humic acid data sets; they showed a greater ionic strength dependency at low pH than at high pH. Forward- and back-titrations with the base and acid revealed hysteresis, particularly at low pH. Previous authors attributed this type of hysteresis to humic acid aggregates-created during the isolation procedure-being redissolved during titration as the pH increased and regarded the results as artificial. However, forward- and back-titrations with organic-rich soils also demonstrated a similar hysteretic behavior. These observations indicate (i) that titrations of humic acid in aggregated form (as opposed to the more usual dissolved form) are more representative of the acid-base properties of humic acid in soil and (ii) that the ionic strength dependency of proton binding in humic acid is related to its degree of aggregation. Thus, the current use of models based on data from dissolved humic substances to predictthe acid-base properties of humic acid in soil under environmental conditions may be flawed and could substantially overestimate their acid buffering capacity.

  12. Developing a multipoint titration method with a variable dose implementation for anaerobic digestion monitoring.

    PubMed

    Salonen, K; Leisola, M; Eerikäinen, T

    2009-01-01

    Determination of metabolites from an anaerobic digester with an acid base titration is considered as superior method for many reasons. This paper describes a practical at line compatible multipoint titration method. The titration procedure was improved by speed and data quality. A simple and novel control algorithm for estimating a variable titrant dose was derived for this purpose. This non-linear PI-controller like algorithm does not require any preliminary information from sample. Performance of this controller is superior compared to traditional linear PI-controllers. In addition, simplification for presenting polyprotic acids as a sum of multiple monoprotic acids is introduced along with a mathematical error examination. A method for inclusion of the ionic strength effect with stepwise iteration is shown. The titration model is presented with matrix notations enabling simple computation of all concentration estimates. All methods and algorithms are illustrated in the experimental part. A linear correlation better than 0.999 was obtained for both acetate and phosphate used as model compounds with slopes of 0.98 and 1.00 and average standard deviations of 0.6% and 0.8%, respectively. Furthermore, insensitivity of the presented method for overlapping buffer capacity curves was shown.

  13. The acid-base buffer capacity of podzolic soils and its changes under the impact of treatment with the Mehra-Jackson and Tamm reagents

    NASA Astrophysics Data System (ADS)

    Maksimova, Yu. G.; Maryakhina, N. N.; Tolpeshta, I. I.; Sokolova, T. A.

    2010-10-01

    The acid-base buffer capacity before and after the treatment with the Mehra-Jackson and Tamm reagents was assessed by continuous potentiometric titration for the main genetic horizons of two profiles of podzolic soils in the Central Forest State Reserve. The total buffer capacity was calculated in the pH range from the initial titration point (ITP) to 3 for the acid titration and from the ITP to 10 for the base titration, as well as the buffer capacities in the pH intervals of 0.25. It was found that both treatments abruptly decreased the base buffer capacity, which reached 70-90% in the E horizons. The high direct linear correlation of the difference between the total base buffer capacities before and after each treatment with the content of Fe in the Tamm extract was revealed. From the results obtained, a conclusion was drawn that finely dispersed Fe hydroxides were the main solid-phase constituents ensuring the base buffer capacity, and the deprotonation of hydroxyl groups on the surface of Fe hydroxides was the essential buffer reaction during the base titration.

  14. 9 CFR 113.110 - Clostridium Botulinum Type C Bacterin-Toxoid.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... challenged intraperitoneally with botulinum Type C toxin which has been titrated in mice to provide for a 104.0 mouse MLD dose. The titration technique shall include inoculation of the mice intraperitoneally...

  15. Determination of sulfur compounds in hydrotreated transformer base oil by potentiometric titration.

    PubMed

    Chao, Qiu; Sheng, Han; Cheng, Xingguo; Ren, Tianhui

    2005-06-01

    A method was developed to analyze the distribution of sulfur compounds in model sulfur compounds by potentiometric titration, and applied to analyze hydrotreated transformer base oil. Model thioethers were oxidized to corresponding sulfoxides by tetrabutylammonium periodate and sodium metaperiodate, respectively, and the sulfoxides were titrated by perchloric acid titrant in acetic anhydride. The contents of aliphatic thioethers and total thioethers were then determined from that of sulfoxides in solution. The method was applied to determine the organic sulfur compounds in hydrotreated transformer base oil.

  16. Thermometric titrimetry Studies of the cerium(IV) oxidation of alpha-mercaptocarboxylic acids.

    PubMed

    Alexander, W A; Mash, C J; McAuley, A

    1969-04-01

    The cerium(IV) oxidation of thioglycollic, thiolactic and thiomalic acids has been examined by thermometric titration. The titration curves indicate stoichiometries of more than 1 mole of cerium(IV) per mole of alpha-thiol, suggesting possible side-reactions. In the presence of methyl acrylate, however, the expected ratio is observed. The overall heat of each reaction has been derived. Only with a titration method of this kind where allowance can be made for side-reactions can the heats of reaction for these systems be measured.

  17. A Colorimetric and Luminescent Dual-Modal Assay for Cu(II) Ion Detection Using an Iridium(III) Complex

    PubMed Central

    Ma, Dik-Lung; He, Hong-Zhang; Chan, Daniel Shiu-Hin; Wong, Chun-Yuen; Leung, Chung-Hang

    2014-01-01

    A novel iridium(III) complex-based chemosensor bearing the 5,6-bis(salicylideneimino)-1,10-phenanthroline ligand receptor was developed, which exhibited a highly sensitive and selective color change from colorless to yellow and a visible turn-off luminescence response upon the addition of Cu(II) ions. The interactions of this iridium(III) complex with Cu2+ ions and thirteen other cations have been investigated by UV-Vis absorption titration, emission titration, and 1H NMR titration. PMID:24927177

  18. Practice Parameters for the Use of Autotitrating Continuous Positive Airway Pressure Devices for Titrating Pressures and Treating Adult Patients with Obstructive Sleep Apnea Syndrome: An Update for 2007

    PubMed Central

    Morgenthaler, Timothy I.; Aurora, R. Nisha; Brown, Terry; Zak, Rochelle; Alessi, Cathy; Boehlecke, Brian; Chesson, Andrew L.; Friedman, Leah; Kapur, Vishesh; Maganti, Rama; Owens, Judith; Pancer, Jeffrey; Swick, Todd J.

    2008-01-01

    These practice parameters are an update of the previously published recommendations regarding the use of autotitrating positive airway pressure (APAP) devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. Continuous positive airway pressure (CPAP) at an effective setting verified by attended polysomnography is a standard treatment for obstructive sleep apnea (OSA). APAP devices change the treatment pressure based on feedback from various patient measures such as airflow, pressure fluctuations, or measures of airway resistance. These devices may aid in the pressure titration process, address possible changes in pressure requirements throughout a given night and from night to night, aid in treatment of OSA when attended CPAP titration has not or cannot be accomplished, or improve patient comfort. A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine has reviewed the literature published since the 2002 practice parameter on the use of APAP. Current recommendations follow: (1) APAP devices are not recommended to diagnose OSA; (2) patients with congestive heart failure, patients with significant lung disease such as chronic obstructive pulmonary disease; patients expected to have nocturnal arterial oxyhemoglobin desaturation due to conditions other than OSA (e.g., obesity hypoventilation syndrome); patients who do not snore (either naturally or as a result of palate surgery); and patients who have central sleep apnea syndromes are not currently candidates for APAP titration or treatment; (3) APAP devices are not currently recommended for split-night titration; (4) certain APAP devices may be used during attended titration with polysomnography to identify a single pressure for use with standard CPAP for treatment of moderate to severe OSA; (5) certain APAP devices may be initiated and used in the self-adjusting mode for unattended treatment of patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (6) certain APAP devices may be used in an unattended way to determine a fixed CPAP treatment pressure for patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (7) patients being treated with fixed CPAP on the basis of APAP titration or being treated with APAP must have close clinical follow-up to determine treatment effectiveness and safety; and (8) a reevaluation and, if necessary, a standard attended CPAP titration should be performed if symptoms do not resolve or the APAP treatment otherwise appears to lack efficacy. Citation: Morgenthaler TI; Aurora RN; Brown T; Zak R; Alessi C; Boehlecke B; Chesson AL; Friedman L; Kapur V; Maganti R; Owens J; Pancer J; Swick TJ; Standards of Practice Committee of the AASM. Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: An update for 2007. SLEEP 2008;31(1):141-147. PMID:18220088

  19. A comparison between simplified and intensive dose-titration algorithms using AIR inhaled insulin for insulin-naive patients with type 2 diabetes in a randomized noninferiority trial.

    PubMed

    Mathieu, C; Cuddihy, R; Arakaki, R F; Belin, R M; Planquois, J-M; Lyons, J N; Heilmann, C R

    2009-09-01

    Insulin initiation and optimization is a challenge for patients with type 2 diabetes. Our objective was to determine whether safety and efficacy of AIR inhaled insulin (Eli Lilly and Co., Indianapolis, IN) (AIR is a registered trademark of Alkermes, Inc., Cambridge, MA) using a simplified regimen was noninferior to an intensive regimen. This was an open-label, randomized study in insulin-naive adults not optimally controlled by oral antihyperglycemic medications. Simplified titration included a 6 U per meal AIR insulin starting dose. Individual doses were adjusted at mealtime in 2-U increments from the previous day's four-point self-monitored blood glucose (SMBG) (total < or =6 U). Starting Air insulin doses for intensive titration were based on fasting blood glucose, gender, height, and weight. Patients conducted four-point SMBG daily for the study duration. Insulin doses were titrated based on the previous 3 days' mean SMBG (total < or =8 U). End point hemoglobin A1C (A1C) was 7.07 +/- 0.09% and 6.87 +/- 0.09% for simplified (n = 178) and intensive (n = 180) algorithms, respectively. Noninferiority between algorithms was not established. The fasting blood glucose (least squares mean +/- standard error) values for the simplified (137.27 +/- 3.42 mg/dL) and intensive (133.13 +/- 3.42 mg/dL) algorithms were comparable. Safety profiles were comparable. The hypoglycemic rate at 4, 8, 12, and 24 weeks was higher in patients receiving intensive titration (all P < .0001). The nocturnal hypoglycemic rate for patients receiving intensive titration was higher than for those receiving simplified titration at 8 (P < 0.015) and 12 weeks (P < 0.001). Noninferiority between the algorithms, as measured by A1C, was not demonstrated. This finding re-emphasizes the difficulty of identifying optimal, simplified insulin regimens for patients.

  20. Number of independent parameters in the potentiometric titration of humic substances.

    PubMed

    Lenoir, Thomas; Manceau, Alain

    2010-03-16

    With the advent of high-precision automatic titrators operating in pH stat mode, measuring the mass balance of protons in solid-solution mixtures against the pH of natural and synthetic polyelectrolytes is now routine. However, titration curves of complex molecules typically lack obvious inflection points, which complicates their analysis despite the high-precision measurements. The calculation of site densities and median proton affinity constants (pK) from such data can lead to considerable covariance between fit parameters. Knowing the number of independent parameters that can be freely varied during the least-squares minimization of a model fit to titration data is necessary to improve the model's applicability. This number was calculated for natural organic matter by applying principal component analysis (PCA) to a reference data set of 47 independent titration curves from fulvic and humic acids measured at I = 0.1 M. The complete data set was reconstructed statistically from pH 3.5 to 9.8 with only six parameters, compared to seven or eight generally adjusted with common semi-empirical speciation models for organic matter, and explains correlations that occur with the higher number of parameters. Existing proton-binding models are not necessarily overparametrized, but instead titration data lack the sensitivity needed to quantify the full set of binding properties of humic materials. Model-independent conditional pK values can be obtained directly from the derivative of titration data, and this approach is the most conservative. The apparent proton-binding constants of the 23 fulvic acids (FA) and 24 humic acids (HA) derived from a high-quality polynomial parametrization of the data set are pK(H,COOH)(FA) = 4.18 +/- 0.21, pK(H,Ph-OH)(FA) = 9.29 +/- 0.33, pK(H,COOH)(HA) = 4.49 +/- 0.18, and pK(H,Ph-OH)(HA) = 9.29 +/- 0.38. Their values at other ionic strengths are more reliably calculated with the empirical Davies equation than any existing model fit.

  1. A geochemical module for "AMDTreat" to compute caustic quantity, effluent quantity, and sludge volume

    USGS Publications Warehouse

    Cravotta, Charles A.; Parkhurst, David L.; Means, Brent P; McKenzie, Bob; Morris, Harry; Arthur, Bill

    2010-01-01

    Treatment with caustic chemicals typically is used to increase pH and decrease concentrations of dissolved aluminum, iron, and/or manganese in largevolume, metal-laden discharges from active coal mines. Generally, aluminum and iron can be removed effectively at near-neutral pH (6 to 8), whereas active manganese removal requires treatment to alkaline pH (~10). The treatment cost depends on the specific chemical used (NaOH, CaO, Ca(OH)2, Na2CO3, or NH3) and increases with the quantities of chemical added and sludge produced. The pH and metals concentrations do not change linearly with the amount of chemical added. Consequently, the amount of caustic chemical needed to achieve a target pH and the corresponding effluent composition and sludge volume can not be accurately determined without empirical titration data or the application of geochemical models to simulate the titration of the discharge water with caustic chemical(s). The AMDTreat computer program (http://amd.osmre.gov/ ) is widely used to compute costs for treatment of coal-mine drainage. Although AMDTreat can use results of empirical titration with industrial grade caustic chemicals to compute chemical costs for treatment of net-acidic or net-alkaline mine drainage, such data are rarely available. To improve the capability of AMDTreat to estimate (1) the quantity and cost of caustic chemicals to attain a target pH, (2) the concentrations of dissolved metals in treated effluent, and (3) the volume of sludge produced by the treatment, a titration simulation is being developed using the geochemical program PHREEQC (wwwbrr.cr.usgs.gov/projects/GWC_coupled/phreeqc/) that will be coupled as a module to AMDTreat. The simulated titration results can be compared with or used in place of empirical titration data to estimate chemical quantities and costs. This paper describes the development, evaluation, and potential utilization of the PHREEQC titration module for AMDTreat.

  2. Equivalence of Nasal and Oronasal Masks during Initial CPAP Titration for Obstructive Sleep Apnea Syndrome

    PubMed Central

    Teo, Ming; Amis, Terence; Lee, Sharon; Falland, Karina; Lambert, Stephen; Wheatley, John

    2011-01-01

    Study Objective: Continuous positive airway pressure (CPAP) titration studies are commonly performed using a nasal mask but some patients may prefer a full-face or oronasal mask. There is little evidence regarding the equivalence of different mask interfaces used to initiate treatment. We hypothesized that oronasal breathing when using an oronasal mask increases upper airway collapsibility and that a higher pressure may be required to maintain airway patency. We also assessed patient preferences for the 2 mask interfaces. Design: Prospective, randomized, cross-over design with 2 consecutive CPAP titration nights. Setting: Accredited laboratory in a university hospital. Patients or Participants: Twenty-four treatment-naive subjects with obstructive sleep apnea syndrome and respiratory disturbance index of greater than 15 events per hour. Interventions: CPAP titration was performed using an auto-titrating machine with randomization to a nasal or oronasal mask, followed by a second titration night using the alternate mask style. Measurements and Results: There was no significant difference in the mean pressures determined between nasal and oronasal masks, although 43% of subjects had nasal-to-oronasal mask-pressure differences of 2 cm H2O or more. Residual respiratory events, arousals, and measured leak were all greater with the oronasal mask. Seventy-nine percent of subjects preferred the nasal mask. Conclusions: Patients with obstructive sleep apnea syndrome can generally switch between nasal and oronasal masks without changing machine pressure, although there are individual differences that may be clinically significant. Measured leak is greater with the oronasal mask. Most patients with obstructive sleep apnea syndrome prefer a nasal mask as the interface for initiation of CPAP. Clinical Trial Registration: Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN12611000243910. URL: http://www.ANZCTR.org.au/ACTRN12611000243910.aspx Citation: Teo M; Amis T; Lee S; Falland K; Lambert S; Wheatley J. Equivalence of nasal and oronasal masks during initial CPAP titration for obstructive sleep apnea syndrome. SLEEP 2011;34(7):951-955. PMID:21731145

  3. Patient-led versus physician-led titration of insulin glargine in patients with uncontrolled type 2 diabetes: a randomized multinational ATLAS study.

    PubMed

    Garg, Satish K; Admane, Karim; Freemantle, Nick; Odawara, Masato; Pan, Chang-Yu; Misra, Anoop; Jarek-Martynowa, Iwona R; Abbas-Raza, Syed; Mirasol, Roberto C; Perfetti, Riccardo

    2015-02-01

    Self-adjustment of insulin dose is commonly practiced in Western patients with type 2 diabetes but is usually not performed in Asian patients. This multinational, 24-week, randomized study compared patient-led with physician-led titration of once-daily insulin glargine in Asian patients with uncontrolled type 2 diabetes who were on 2 oral glucose-lowering agents. Patient-led (n = 275) or physician-led (n = 277) subjects followed the same dose-titration algorithm guided by self-monitored fasting blood glucose (FBG; target, 110 mg/dL [6.1 mmol/L]). The primary endpoint was change in mean glycated hemoglobin (HbA1c) at week 24 in the patient-led versus physician-led titration groups. Patient-led titration resulted in a significantly higher drop in HbA1c value at 24 weeks when compared with physician-led titration (-1.40% vs. -1.25%; mean difference, -0.15; 95% confidence interval, -0.29 to 0.00; P = .043). Mean decrease in FBG was greatest in the patient-led group (-2.85 mmol/L vs. -2.48 mmol/L; P = .001). The improvements in HbA1c and FBG were consistent across countries, with similar improvements in treatment satisfaction in both groups. Mean daily insulin dose was higher in the patient-led group (28.9 units vs. 22.2 units; P<.001). Target HbA1c of <7.0% without severe hypoglycemia was achieved in 40.0% and 32.9% in the patient-led and physician-led groups, respectively (P = .086). Severe hypoglycemia was not different in the 2 groups (0.7%), with an increase in nocturnal and symptomatic hypoglycemia in the patient-led arm. Patient-led insulin glargine titration achieved near-target blood glucose levels in Asian patients with uncontrolled type 2 diabetes who were on 2 oral glucose-lowering drugs, demonstrating that Asian patients can self-uptitrate insulin dose effectively when guided.

  4. Effectiveness of a management program for outpatient clinic or remote titration of beta-blockers in CRT patients: The RESTORE study.

    PubMed

    D'Onofrio, Antonio; Palmisano, Pietro; Rapacciuolo, Antonio; Ammendola, Ernesto; Calò, Leonardo; Ruocco, Antonio; Bianchi, Valter; Maresca, Fabio; Del Giorno, Giuseppe; Martino, Annamaria; Mauro, Ciro; Campari, Monica; Valsecchi, Sergio; Accogli, Michele

    2017-06-01

    Many patients fail to receive β-blockers before cardiac resynchronization therapy defibrillator (CRT-D) implantation, or receive them at a suboptimal dose, and require optimization after implantation. We assessed the effectiveness of a structured program for β-blocker titration in CRT-D patients followed up by means of conventional in-clinic visits or remote monitoring. 130 patients undergoing CRT implantation and treated according to the standard practice of the centers were included as a control group. A second group of 124 CRT-D candidates (Study Group) underwent up-titration visits every 2weeks after implantation (target dose: 10mg/day of bisoprolol or 50mg/day of carvedilol). In the Study Group, remote monitoring was undertaken in 66 patients, who received additional equipment for daily transmission of weight and blood pressure data, and scheduled titration telephone calls. In the Control Group, the maximal dose of β-blockers was being administered to 12 (9%) patients on implantation and 21 (16%) on 6-month follow-up examination (p>0.05). In the Study Group, 25 (20%) patients were receiving the maximal dose of β-blockers on implantation and 72 (58%) on follow-up examination (p<0.001). The 66 Study Group patients on remote monitoring underwent fewer in-clinic visits (p=0.034). Of these, 50 (76%) were on the maximal dose after remote up-titration (versus 38% of patients followed up conventionally, p<0.001). The decrease in left ventricular end-systolic volume was larger in the Study Group (p=0.040). The program for β-blocker up-titration increased the number of patients reaching the target dose and improved the response to the therapy. The use of remote monitoring and daily transfer of weight and blood pressure data facilitated β-blocker titration. URL: http://clinicaltrials.gov/ Identifier: NCT02173028. Copyright © 2017. Published by Elsevier B.V.

  5. A comparison of sports and energy drinks--Physiochemical properties and enamel dissolution.

    PubMed

    Jain, Poonam; Hall-May, Emily; Golabek, Kristi; Agustin, Ma Zenia

    2012-01-01

    The consumption of sports and energy drinks by children and adolescents has increased at an alarming rate in recent years. It is essential for dental professionals to be informed about the physiochemical properties of these drinks and their effects on enamel. The present study measured the fluoride levels, pH, and titratable acidity of multiple popular, commercially available brands of sports and energy drinks. Enamel dissolution was measured as weight loss using an in vitro multiple exposure model consisting of repeated short exposures to these drinks, alternating with exposure to artificial saliva. The relationship between enamel dissolution and fluoride levels, pH, and titratable acidity was also examined. There was a statistically significant difference between the fluoride levels (p = 0.034) and pH (p = 0.04) of the sports and energy drinks studied. The titratable acidity of energy drinks (11.78) was found to be significantly higher than that of sports drinks (3.58) (p < 0.001). Five of the energy drinks (Red Bull Sugar Free, Monster Assault, Von Dutch, Rockstar, and 5-Hour Energy) were found to have the highest titratable acidity values among the brands studied. Enamel weight loss after exposure to energy drinks was significantly higher than it was after exposure to sports drinks. The effect of titratable acidity on enamel weight loss was found to vary inversely with the pH of the drinks. The findings indicated that energy drinks have significantly higher titratable acidity and enamel dissolution associated with them than sports drinks. Enamel weight loss after exposure to energy drinks was more than two times higher than it was after exposure to sports drinks. Titratable acidity is a significant predictor of enamel dissolution, and its effect on enamel weight loss varies inversely with the pH of the drink. The data from the current study can be used to educate patients about the differences between sports and energy drinks and the effects of these drinks on tooth enamel.

  6. A Pediatric Intensive Care Unit Bedside Computer Clinical Decision Support Protocol for Hyperglycemia Is Feasible, Safe and Offers Advantages

    PubMed Central

    Lanspa, Michael J.; Wilson, Emily L.; Sward, Katherine A.; Jephson, Al; Larsen, Gitte Y.; Morris, Alan H.

    2017-01-01

    Abstract Background: Computer clinical decision support (CDS) systems are uncommon in the pediatric intensive care unit (PICU), despite evidence suggesting they improve outcomes in adult ICUs. We reasoned that a bedside CDS protocol for intravenous insulin titration, eProtocol-insulin, would be feasible and safe in critically ill children. Methods: We retrospectively reviewed data from non-diabetic children admitted to the PICU with blood glucose (BG) ≥140 mg/dL who were managed with intravenous insulin by either unaided clinician titration or eProtocol-insulin. Primary outcomes were BG measurements in target range (80–110 mg/dL) and severe hypoglycemia (BG ≤40 mg/dL); secondary outcomes were 60-day mortality and PICU length of stay. We assessed bedside nurse satisfaction with the eProtocol-insulin protocol by using a 5-point Likert scale and measured clinician compliance with eProtocol-insulin recommendations. Results: Over 5 years, 69 children were titrated with eProtocol-insulin versus 104 by unaided clinicians. eProtocol-insulin achieved target range more frequently than clinician titration (41% vs. 32%, P < 0.001). Severe hypoglycemia was uncommon in both groups (4.3% of patients in eProtocol-insulin, 8.7% in clinician titration, P = 0.37). There were no differences in mean time to BG target or median BG between the groups. Mortality was 23% in both groups. Clinician compliance with eProtocol-insulin recommendations was 89%. Nurses believed that eProtocol-insulin was easy to understand and safer than clinician titration. Conclusions: eProtocol-insulin is safe for titration of intravenous insulin in critically ill children. Clinical research protocols and quality improvement initiatives aimed at optimizing BG control should utilize detailed computer protocols that enable replicable clinician decisions. PMID:28248127

  7. Effect of neuromonitor-guided titrated care on brain tissue hypoxia after opioid overdose cardiac arrest.

    PubMed

    Elmer, Jonathan; Flickinger, Katharyn L; Anderson, Maighdlin W; Koller, Allison C; Sundermann, Matthew L; Dezfulian, Cameron; Okonkwo, David O; Shutter, Lori A; Salcido, David D; Callaway, Clifton W; Menegazzi, James J

    2018-04-18

    Brain tissue hypoxia may contribute to preventable secondary brain injury after cardiac arrest. We developed a porcine model of opioid overdose cardiac arrest and post-arrest care including invasive, multimodal neurological monitoring of regional brain physiology. We hypothesized brain tissue hypoxia is common with usual post-arrest care and can be prevented by modifying mean arterial pressure (MAP) and arterial oxygen concentration (PaO 2 ). We induced opioid overdose and cardiac arrest in sixteen swine, attempted resuscitation after 9 min of apnea, and randomized resuscitated animals to three alternating 6-h blocks of standard or titrated care. We invasively monitored physiological parameters including brain tissue oxygen (PbtO 2 ). During standard care blocks, we maintained MAP > 65 mmHg and oxygen saturation 94-98%. During titrated care, we targeted PbtO2 > 20 mmHg. Overall, 10 animals (63%) achieved ROSC after a median of 12.4 min (range 10.8-21.5 min). PbtO 2 was higher during titrated care than standard care blocks (unadjusted β = 0.60, 95% confidence interval (CI) 0.42-0.78, P < 0.001). In an adjusted model controlling for MAP, vasopressors, sedation, and block sequence, PbtO 2 remained higher during titrated care (adjusted β = 0.75, 95%CI 0.43-1.06, P < 0.001). At three predetermined thresholds, brain tissue hypoxia was significantly less common during titrated care blocks (44 vs 2% of the block duration spent below 20 mmHg, P < 0.001; 21 vs 0% below 15 mmHg, P < 0.001; and, 7 vs 0% below 10 mmHg, P = .01). In this model of opioid overdose cardiac arrest, brain tissue hypoxia is common and treatable. Further work will elucidate best strategies and impact of titrated care on functional outcomes. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Thermodynamics of Ligand Binding to a Heterogeneous RNA Population in the Malachite Green Aptamer

    PubMed Central

    Sokoloski, Joshua E.; Dombrowski, Sarah E.; Bevilacqua, Philip C.

    2011-01-01

    The malachite green aptamer binds two closely related ligands, malachite green (MG) and tetramethylrosamine (TMR), with near equal affinity. The MG ligand consists of three phenyl rings emanating from a central carbon, while TMR has two of the three rings connected by an ether linkage. The binding pockets for MG and TMR in the aptamer, known from high-resolution structure, differ only in the conformation of a few nucleotides. Herein, we applied isothermal titration calorimetry (ITC) to compare the thermodynamics for binding of MG and TMR to the aptamer. Binding heat capacities were obtained from ITC titrations over the temperature range of 15 to 60 °C. Two temperature regimes were found for MG binding: one from 15 to 45 °C where MG bound with a large negative heat capacity and an apparent stoichiometry (n) of ~0.4, and another from 50 to 60 °C where MG bound with positive heat capacity and n~1.1. The binding of TMR, on the other hand, revealed only one temperature regime for binding, with a more modest negative heat capacity and n~1.2. The large difference in heat capacity between the two ligands suggests that significantly more conformational rearrangement occurs upon the binding of MG than TMR, which is consistent with differences in solvent accessible surface area calculated for available ligand-bound structures. Lastly, we note that binding stoichiometry of MG was improved not only by raising the temperature, but also by lowering the concentration of Mg2+ or increasing the time between ITC injections. These studies suggest that binding of a dynamical ligand to a functional RNA requires the RNA itself to have significant dynamics. PMID:22192051

  9. Amperometric, Bipotentiometric, and Coulometric Titration.

    ERIC Educational Resources Information Center

    Stock, John T.

    1984-01-01

    Reviews literature on amperometric, bipotentiometric, and coulometric titration methods examining: apparatus and methodology; acid-base reactions; precipitation and complexing reactions (considering methods involving silver, mercury, EDTA or analogous reagents, and other organic compounds); and oxidation-reduction reactions (considering methods…

  10. An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid.

    PubMed

    van Staden, J F; Mashamba, Mulalo G; Stefan, Raluca I

    2002-09-01

    An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid is proposed. A solution of 0.1 mol L(-1) sodium chloride is used as carrier. Titration is achieved by aspirating acetic acid samples between two strong base-zone volumes into a holding coil and by channelling the stack of well-defined zones with flow reversal through a reaction coil to a potentiometric sensor where the peak widths were measured. A linear relationship between peak width and logarithm of the acid concentration was obtained in the range 1-9 g/100 mL. Vinegar samples were analysed without any sample pre-treatment. The method has a relative standard deviation of 0.4% with a sample frequency of 28 samples per hour. The results revealed good agreement between the proposed sequential injection and an automated batch titration method.

  11. Competitive counterion complexation allows the true host : guest binding constants from a single titration by ionic receptors.

    PubMed

    Pessêgo, Márcia; Basílio, Nuno; Muñiz, M Carmen; García-Río, Luis

    2016-07-06

    Counterion competitive complexation is a background process currently ignored by using ionic hosts. Consequently, guest binding constants are strongly affected by the design of the titration experiments in such a way that the results are dependent on the guest concentration and on the presence of added salts, usually buffers. In the present manuscript we show that these experimental difficulties can be overcome by just considering the counterion competitive complexation. Moreover a single titration allows us to obtain not only the true binding constants but also the stoichiometry of the complex showing the formation of 1 : 1 : 1 (host : guest : counterion) complexes. The detection of high stoichiometry complexes is not restricted to a single titration experiment but also to a displacement assay where both competitive and competitive-cooperative complexation models are taken into consideration.

  12. Thermometric titration of thorium with EDTA in the presence of large excess of neutral sodium salts.

    PubMed

    Doi, K

    1980-11-01

    The thermometric titration of Th(IV) in the presence of neutral sodium salts, sulphuric acid or acetic acid with EDTA has been studied. The effect of each on the observed heat values for the titration is discussed. For sodium perchlorate media, DeltaH values of -9 and -21 kJ/mole have been estimated for the formation of the Th(IV)-EDTA chelate at mu --> 0 and mu = 0.5 (NaClO(4)), respectively. The -DeltaH values increase steadily with increase in concentration of sodium perchlorate up to at least 3M. For the titration of Th(IV) in the presence of a large excess of sodium nitrate the use of sodium iodide as a masking reagent has been examined: large amounts of Bi and Cu(II) are masked and a masking effect is observed for small amounts of Ni.

  13. Increasing the Detection Limit of the Parkinson Disorder through a Specific Surface Chemistry Applied onto Inner Surface of the Titration Well.

    PubMed

    Mille, Caroline; Debarnot, Dominique; Zorzi, Willy; El Moualij, Benaïssa; Coudreuse, Arnaud; Legeay, Gilbert; Quadrio, Isabelle; Perret-Liaudet, Armand; Poncin-Epaillard, Fabienne

    2012-04-18

    The main objective of this paper was to illustrate the enhancement of the sensitivity of ELISA titration for neurodegenerative proteins by reducing nonspecific adsorptions that could lead to false positives. This goal was obtained thanks to the association of plasma and wet chemistries applied to the inner surface of the titration well. The polypropylene surface was plasma-activated and then, dip-coated with different amphiphilic molecules. These molecules have more or less long hydrocarbon chains and may be charged. The modified surfaces were characterized in terms of hydrophilic-phobic character, surface chemical groups and topography. Finally, the coated wells were tested during the ELISA titration of the specific antibody capture of the α-synuclein protein. The highest sensitivity is obtained with polar (Θ = 35°), negatively charged and smooth inner surface.

  14. Increasing the Detection Limit of the Parkinson Disorder through a Specific Surface Chemistry Applied onto Inner Surface of the Titration Well

    PubMed Central

    Mille, Caroline; Debarnot, Dominique; Zorzi, Willy; Moualij, Benaïssa El; Coudreuse, Arnaud; Legeay, Gilbert; Quadrio, Isabelle; Perret-Liaudet, Armand; Poncin-Epaillard, Fabienne

    2012-01-01

    The main objective of this paper was to illustrate the enhancement of the sensitivity of ELISA titration for neurodegenerative proteins by reducing nonspecific adsorptions that could lead to false positives. This goal was obtained thanks to the association of plasma and wet chemistries applied to the inner surface of the titration well. The polypropylene surface was plasma-activated and then, dip-coated with different amphiphilic molecules. These molecules have more or less long hydrocarbon chains and may be charged. The modified surfaces were characterized in terms of hydrophilic—phobic character, surface chemical groups and topography. Finally, the coated wells were tested during the ELISA titration of the specific antibody capture of the α-synuclein protein. The highest sensitivity is obtained with polar (Θ = 35°), negatively charged and smooth inner surface. PMID:24955533

  15. Titrimetric and photometric methods for determination of hypochlorite in commercial bleaches.

    PubMed

    Jonnalagadda, Sreekanth B; Gengan, Prabhashini

    2010-01-01

    Two methods, simple titration and photometric methods for determination of hypochlorite are developed, based its reaction with hydrogen peroxide and titration of the residual peroxide by acidic permanganate. In the titration method, the residual hydrogen peroxide is estimated by titration with standard permanganate solution to estimate the hypochlorite concentration. The photometric method is devised to measure the concentration of remaining permanganate, after the reaction with residual hydrogen peroxide. It employs 4 ranges of calibration curves to enable the determination of hypochlorite accurately. The new photometric method measures hypochlorite in the range 1.90 x 10(-3) to 1.90 x 10(-2) M, with high accuracy and with low variance. The concentrations of hypochlorite in diverse commercial bleach samples and in seawater which is enriched with hypochlorite were estimated using the proposed method and compared with the arsenite method. The statistical analysis validates the superiority of the proposed method.

  16. Studies of cellulose surfaces by titration and ESCA

    NASA Astrophysics Data System (ADS)

    Stenius, Per; Laine, Janne

    1994-01-01

    The surface properties of unbleached kraft pulp fibers of varying lignin content prepared by digestion with different amounts of excess alkali have been investigated using polyelectrolyte titration, potentiometric titration and ESCA. The surfaces contain two different acidic groups that dissociate completely above pH 7.5, one with pK ≈ 3.6 and one with pK ≈ 5.7. The amount of the latter group correlates directly with the amount of lignin in the pulp. The ESCA analysis indicates that the relative amount of carboxylic groups and alkyl carbon in the surface decreases as the lignin content decreases and also that material with high alkyl carbon content is enriched in the outermost surface of the cellulose. Thus, a combination of ESCA analysis and high-precision titrations is able to yield a very detailed picture of the effect of digestion conditions on surface properties of cellulose fibers of direct relevance to paper properties.

  17. Determination of sulphite in wine by coulometric titration.

    PubMed

    Lowinsohn, D; Bertotti, M

    2001-09-01

    A method for the determination of both free and bound S(IV) in white wine samples by coulometric titration with electrogenerated iodine is described, the S(IV) speciation being performed by extracting SO2 from samples acidified wiith hydrochloric acid. Titrations of samples treated with NaOH led to the total S(IV) concentration, the results being in agreement with the ones obtained by the distillation procedure as well as by using the classical Monier-Williams method. An average recovery of 97% was obtained for samples spiked with S(IV) in the range 0.4-1.2 mM, which demonstrated the validity of the proposed procedure. The repeatability was 1.3% and the limit of detection was estimated as 0.01 mM. Results from direct titrations of wine added to the electrochemical cell are reported, which give indications of the stability of adducts towards the reaction with iodine.

  18. AMDTreat 5.0+ with PHREEQC titration module to compute caustic chemical quantity, effluent quality, and sludge volume

    USGS Publications Warehouse

    Cravotta, Charles A.; Means, Brent P; Arthur, Willam; McKenzie, Robert M; Parkhurst, David L.

    2015-01-01

    Alkaline chemicals are commonly added to discharges from coal mines to increase pH and decrease concentrations of acidity and dissolved aluminum, iron, manganese, and associated metals. The annual cost of chemical treatment depends on the type and quantities of chemicals added and sludge produced. The AMDTreat computer program, initially developed in 2003, is widely used to compute such costs on the basis of the user-specified flow rate and water quality data for the untreated AMD. Although AMDTreat can use results of empirical titration of net-acidic or net-alkaline effluent with caustic chemicals to accurately estimate costs for treatment, such empirical data are rarely available. A titration simulation module using the geochemical program PHREEQC has been incorporated with AMDTreat 5.0+ to improve the capability of AMDTreat to estimate: (1) the quantity and cost of caustic chemicals to attain a target pH, (2) the chemical composition of the treated effluent, and (3) the volume of sludge produced by the treatment. The simulated titration results for selected caustic chemicals (NaOH, CaO, Ca(OH)2, Na2CO3, or NH3) without aeration or with pre-aeration can be compared with or used in place of empirical titration data to estimate chemical quantities, treated effluent composition, sludge volume (precipitated metals plus unreacted chemical), and associated treatment costs. This paper describes the development, evaluation, and potential utilization of the PHREEQC titration module with the new AMDTreat 5.0+ computer program available at http://www.amd.osmre.gov/.

  19. Nurse-coordinated care improves the achievement of LDL cholesterol targets through more intensive medication titration

    PubMed Central

    Snaterse, Marjolein; Jorstad, Harald T; Heiligenberg, Marlies; ter Riet, Gerben; Boekholdt, S Matthijs; Scholte op Reimer, Wilma; Peters, Ron J

    2017-01-01

    Background Nurse-coordinated care (NCC) improves the achievement of low-density lipoprotein-cholesterol (LDL-C) targets after an acute coronary syndrome (ACS). We hypothesised that NCC improves achievement of LDL-C targets through more intensive medication titration. Methods We used data from Randomised Evaluation of Secondary Prevention by Outpatient Nurse Specialists (RESPONSE), a multicentre randomised trial on the efficacy of NCC in 754 ACS patients. Follow-up data were collected at 6 and 12 months. To enable comparison between the various types and dosages of statins, we used the average lipid-lowering potency (ALLP, % LDL-C lowering) as an indicator of lipid-lowering medication intensity. Results Most patients in NCC intervention and usual care groups (96%) had started lipid-lowering therapy during the index hospitalisation. At 6 months, titration activities (up or down) were applied in 45% of NCC patients compared with 24% of patients receiving usual care (p<0.001), and a difference was also seen at 12 months follow-up (52% vs 34%, p<0.001). In patients not on LDL-C target at baseline, titration activities at 6 months were recorded in 63% and 30% of NCC and usual care patients respectively (p<0.001), with increased titration activities in both groups at 12 months (69% vs 43%, p<0.001). Conclusion NCC is associated with more frequent and intense lipid-lowering medication titration to reach LDL-C targets as compared with usual care alone. Further, merely starting the guideline-recommended dose is insufficient to reach the guideline-recommended LDL-C target level. Trial Registration number TC1290 (Netherlands). PMID:28761680

  20. Nurse-coordinated care improves the achievement of LDL cholesterol targets through more intensive medication titration.

    PubMed

    Snaterse, Marjolein; Jorstad, Harald T; Heiligenberg, Marlies; Ter Riet, Gerben; Boekholdt, S Matthijs; Scholte Op Reimer, Wilma; Peters, Ron J

    2017-01-01

    Nurse-coordinated care (NCC) improves the achievement of low-density lipoprotein-cholesterol (LDL-C) targets after an acute coronary syndrome (ACS). We hypothesised that NCC improves achievement of LDL-C targets through more intensive medication titration. We used data from Randomised Evaluation of Secondary Prevention by Outpatient Nurse Specialists (RESPONSE), a multicentre randomised trial on the efficacy of NCC in 754 ACS patients. Follow-up data were collected at 6 and 12 months. To enable comparison between the various types and dosages of statins, we used the average lipid-lowering potency (ALLP, % LDL-C lowering) as an indicator of lipid-lowering medication intensity. Most patients in NCC intervention and usual care groups (96%) had started lipid-lowering therapy during the index hospitalisation. At 6 months, titration activities (up or down) were applied in 45% of NCC patients compared with 24% of patients receiving usual care (p<0.001), and a difference was also seen at 12 months follow-up (52% vs 34%, p<0.001). In patients not on LDL-C target at baseline, titration activities at 6 months were recorded in 63% and 30% of NCC and usual care patients respectively (p<0.001), with increased titration activities in both groups at 12 months (69% vs 43%, p<0.001). NCC is associated with more frequent and intense lipid-lowering medication titration to reach LDL-C targets as compared with usual care alone. Further, merely starting the guideline-recommended dose is insufficient to reach the guideline-recommended LDL-C target level. TC1290 (Netherlands).

  1. Comparison of a specific HPLC determination of toxic aconite alkaloids in processed Radix aconiti with a titration method of total alkaloids.

    PubMed

    Csupor, Dezso; Borcsa, Botond; Heydel, Barbara; Hohmann, Judit; Zupkó, István; Ma, Yan; Widowitz, Ute; Bauer, Rudolf

    2011-10-01

    In traditional Chinese medicine, Aconitum (Ranunculaceae) roots are only applied after processing. Nevertheless, several cases of poisoning by improperly processed aconite roots have been reported. The aim of this study was to develop a reliable analytical method to assess the amount of toxic aconite alkaloids in commercial aconite roots, and to compare this method with the commonly used total alkaloid content determination by titration. The content of mesaconitine, aconitine, and hypaconitine in 16 commercial samples of processed aconite roots was determined by an HPLC method and the total alkaloid content by indirect titration. Five samples were selected for in vivo toxicological investigation. In most of the commercial samples, toxic alkaloids were not detectable, or only traces were found. In four samples, we could detect >0.04% toxic aconite alkaloids, the highest with a content of 0.16%. The results of HPLC analysis were compared with the results obtained by titration, and no correlation was found between the two methods. The in vivo results reassured the validity of the HPLC determination. Samples with mesaconitine, aconitine, and hypaconitine content below the HPLC detection limit still contained up to 0.2% alkaloids determined by titration. Since titration of alkaloids gives no information selectively on the aconitine-type alkaloid content and toxicity of aconite roots this method is not appropriate for safety assessment. The HPLC method developed by us provides a quick and reliable assessment of toxicity and should be considered as a purity test in pharmacopoeia monographs.

  2. Titration of Alanine Monitored by NMR Spectroscopy: A Biochemistry Laboratory Experiment

    ERIC Educational Resources Information Center

    Waller, Francis J.; And Others

    1977-01-01

    The experiment described here involves simultaneous monitoring of pH and NMR chemical shifts during an aqueous titration of alpha- and beta-alanine. This experiment is designed for use in an undergraduate biochemistry course. (MR)

  3. A Computer-Based Simulation of an Acid-Base Titration

    ERIC Educational Resources Information Center

    Boblick, John M.

    1971-01-01

    Reviews the advantages of computer simulated environments for experiments, referring in particular to acid-base titrations. Includes pre-lab instructions and a sample computer printout of a student's use of an acid-base simulation. Ten references. (PR)

  4. Going Beyond, Going Further: The Preparation of Acid-Base Titration Curves.

    ERIC Educational Resources Information Center

    McClendon, Michael

    1984-01-01

    Background information, list of materials needed, and procedures used are provided for a simple technique for generating mechanically plotted acid-base titration curves. The method is suitable for second-year high school chemistry students. (JN)

  5. Determination of active oxygen in the presence of barium and lead

    USGS Publications Warehouse

    Fleischer, M.

    1943-01-01

    The method of Mrgudich and Clark is modified by substituting 5 per cent (by volume) perchloric acid for 50 per cent perchloric acid. Titration by potassium permanganate may be substituted for electrometric titration with ceric sulfate.

  6. Potential benefits of slow titration of paroxetine treatment in an elderly population: eight-week results from a naturalistic setting.

    PubMed

    Gibiino, Sara; Mori, Elisa; De Ronchi, Diana; Serretti, Alessandro

    2013-08-01

    Late-life depression, often in association with anxiety, affects approximately 15% of individuals older than 65 years. Selective serotonin reuptake inhibitors are the first-line treatment but could be responsible of an early exacerbation of anxiety, possibly reduced by a very gradual titration of drugs. The main aim of this study is to compare gradual and rapid (standard) titration of paroxetine in an elderly population. In a naturalistic setting, 50 elderly (≥60 years old) outpatients with unipolar mood disorder or anxiety disorder were naturalistically assigned to abrupt initiation of 10 mg of paroxetine or to a gradual increase with 2.5 mg on alternate days up to 10 mg in 7 days. Then dosage could be maintained at 10 mg or increased according to clinical response. Primary outcome was efficacy as assessed by the Hamilton Depression Rating Scale (HAM-D) 21, HAM-D symptom subscales (core, psychic anxiety, somatic anxiety cluster), and Hamilton Anxiety Rating Scale changes. Secondary outcome was evaluation of overall dropouts at eighth week and evaluation of most common adverse effects through the global judgment of the Dosage Record and Treatment Emergent Symptom Scale. All data were recorded weekly for the first 8 weeks of treatment (with 1 more evaluation after 3 days from the baseline). Samples were comparable at baseline, with patients in gradual titration showing a higher level of psychic anxiety. During the first 3 days of treatment, a significant worsening in psychic anxiety was observed in patients treated abruptly with 10 mg of paroxetine (difference in HAM-D psychic anxiety subscale from baseline: 110.61% vs 89.38% with rapid and slow titration, respectively; t test P = 0.03). Overall, a significantly greater improvement in depressive and anxious symptoms favored gradual titration (HAM-D core cluster and HAM-D psychic anxiety cluster, respectively, P = 0.014 and P < 0.001, also when controlling for confounders). At the eighth week, significant higher dropouts in patients administered with abrupt dosage was observed (12.00% vs 40.91%, P = 0.02, respectively for slow and rapid titration). Our results suggest that a gradual titration of paroxetine could avoid the initial treatment anxiety worsening and dropout at the beginning of the treatment.

  7. The Mobile Insulin Titration Intervention (MITI) for Insulin Glargine Titration in an Urban, Low-Income Population: Randomized Controlled Trial Protocol.

    PubMed

    Levy, Natalie; Moynihan, Victoria; Nilo, Annielyn; Singer, Karyn; Bernik, Lidia S; Etiebet, Mary-Ann; Fang, Yixin; Cho, James; Natarajan, Sundar

    2015-03-13

    Patients on insulin glargine typically visit a clinician to obtain advice on how to adjust their insulin dose. These multiple clinic visits can be costly and time-consuming, particularly for low-income patients. It may be feasible to achieve insulin titration through text messages and phone calls with patients instead of face-to-face clinic visits. The objectives of this study are to (1) evaluate if the Mobile Insulin Titration Intervention (MITI) is clinically effective by helping patients reach their optimal dose of insulin glargine, (2) determine if the intervention is feasible within the setting and population, (3) assess patient satisfaction with the intervention, and (4) measure the costs associated with this intervention. This is a pilot study evaluating an approach to insulin titration using text messages and phone calls among patients with insulin-dependent type 2 diabetes in the outpatient medical clinic of Bellevue Hospital Center, a safety-net hospital in New York City. Patients will be randomized in a 1:1 ratio to either the MITI arm (texting/phone call intervention) or the usual-care arm (in-person clinic visits). Using a Web-based platform, weekday text messages will be sent to patients in the MITI arm, asking them to text back their fasting blood glucose values. In addition to daily reviews for alarm values, a clinician will rereview the texted values weekly, consult our physician-approved titration algorithm, and call the patients with advice on how to adjust their insulin dose. The primary outcome will be whether or not a patient reaches his/her optimal dose of insulin glargine within 12 weeks. Recruitment for this study occurred between June 2013 and December 2014. We are continuing to collect intervention and follow-up data from our patients who are currently enrolled. The results of our data analysis are expected to be available in 2015. This study explores the use of widely-available text messaging and voice technologies for insulin titration. We aim to show that remote insulin titration is clinically effective, feasible, satisfactory, and cost saving for low-income patients in a busy, urban clinic. Clinicaltrials.gov NCT01879579; http://clinicaltrials.gov/ct2/show/NCT01879579 (Archived by WebCite at http://www.webcitation.org/6WUEgjZUO).

  8. Impact of systolic blood pressure on the safety and tolerability of initiating and up-titrating sacubitril/valsartan in patients with heart failure and reduced ejection fraction: insights from the TITRATION study.

    PubMed

    Senni, Michele; McMurray, John J V; Wachter, Rolf; McIntyre, Hugh F; Anand, Inder S; Duino, Vincenzo; Sarkar, Arnab; Shi, Victor; Charney, Alan

    2018-03-01

    The TITRATION trial investigated two strategies to initiate and up-titrate sacubitril/valsartan (LCZ696) to the same target dose, over a condensed (3-week) or conservative (6-week) period, in patients with heart failure with reduced ejection fraction (HFrEF) and systolic blood pressure (SBP) of ≥100 mmHg. This post hoc analysis examined the relationship between baseline SBP at screening and achievement of the target dose of sacubitril/valsartan of 97 mg/103 mg (also termed 'LCZ696 200 mg') twice per day during the study. Patients (n = 498) were categorized in four groups based on SBP at screening: 100-110 mmHg (n = 70); 111-120 mmHg (n = 93); 121-139 mmHg (n = 168) and ≥140 mmHg (n = 167). Overall, 72.7%, 76.1%, 85.6% and 82.9%, respectively, of patients in these SBP categories achieved and maintained the target dose of sacubitril/valsartan without down-titration/dose interruption over 12 weeks ('treatment success'). Compared with patients with SBP of 100-110 mmHg, rates of treatment success among patients in the higher SBP groups [111-120 mmHg (P = 0.96); 121-139 mmHg (P = 0.06) and ≥140 mmHg (P = 0.25)] did not differ significantly. A higher percentage of patients with lower SBP (100-110 mmHg) achieved treatment success with gradual up-titration (6 weeks) (∼80%) than with rapid up-titration (∼69%). Similar findings were observed with regard to 'tolerability success' (maintenance of the target dose for at least the final 2 weeks prior to study completion). Hypotension occurred more frequently in patients with lower SBP. The majority of patients (>80%) with SBP of ≥100 mmHg achieved and maintained the target dose of sacubitril/valsartan if the treatment was titrated gradually. These findings suggest that low SBP should not prevent clinicians from considering the initiation of sacubitril/valsartan. © 2017 The Authors. European Journal of Heart Failure © 2017 European Society of Cardiology.

  9. The Reduction of Sulfuryl Chloride at Teflon-Bonded Carbon Cathodes

    DTIC Science & Technology

    1980-07-01

    titrated mulating cathodes, along with their BET surface potentiometrically with standardized silver nitrate areas. Shawinigan black possesses the...assembly steps when individually dissolved can be titrated through were accomplished in the glove box. iodimetry or iodometry, respectively (7). If

  10. Using Spreadsheets to Produce Acid-Base Titration Curves.

    ERIC Educational Resources Information Center

    Cawley, Martin James; Parkinson, John

    1995-01-01

    Describes two spreadsheets for producing acid-base titration curves, one uses relatively simple cell formulae that can be written into the spreadsheet by inexperienced students and the second uses more complex formulae that are best written by the teacher. (JRH)

  11. Coulometric titration of potassium hydrogen phthalate in a non-aqueous solution, with a vitreous carbon anode.

    PubMed

    Jennings, V J; Dodson, A; Tedds, G

    1974-06-01

    A vitreous carbon anode has been used as working electrode in the coulometric titration of potassium hydrogen phthalate in glacial acetic acid-acetic anhydride medium with protous generated electrochemical oxidation of quinol.

  12. Computer Series, 62: Bits and Pieces, 25.

    ERIC Educational Resources Information Center

    Moore, John W., Ed.

    1985-01-01

    Describes: (1) a FORTH-language, computer-controlled potentiometric titration; (2) coulometric titrations using computer-interfaced potentiometric endpoint detection; (3) interfacing a scanning infrared spectrophotometer to a microcomputer; (4) demonstrations of signal-to-noise enhancement (digital filtering); (5) and an inexpensive Apple…

  13. Zinc(II) complexation by some biologically relevant pH buffers.

    PubMed

    Wyrzykowski, D; Tesmar, A; Jacewicz, D; Pranczk, J; Chmurzyński, L

    2014-12-01

    The isothermal titration calorimetry (ITC) technique supported by potentiometric titration data was used to study the interaction of zinc ions with pH buffer substances, namely 2-(N-morpholino)ethanesulfonic acid (Mes), piperazine-N,N'-bis(2-ethanesulfonic acid) (Pipes), and dimethylarsenic acid (Caco). The displacement ITC titration method with nitrilotriacetic acid as a strong, competitive ligand was applied to determine conditional-independent thermodynamic parameters for the binding of Zn(II) to Mes, Pipes, and Caco. Furthermore, the relationship between the proposed coordination mode of the buffers and the binding enthalpy has been discussed. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Thermodynamic and NMR Studies of Solvent Effect on Enantiomeric Recognition for a Chiral Organiz Ammonium Cation by Chiral Diketopyridino-18- Crown-6 Type Ligands at 25.0 deg C.

    DTIC Science & Technology

    1994-05-11

    analyses, 1H NM&, and JR specPit oscopy. The purities were also determined quantitatively by a thermometric titration technique. 19 By titrting...enantiomers of NapEt with 18- crown-6 (SIGMA Chemical Company, its purity was 99.5% as determined by therm--ometric titration agtains a standard NaBr...isoperibol titration calorimetry at 25.0 - 0.1oC in CACi6CHOH solvent mixtures. The initial solution volume in the dewar was 20 mL Tne calorimeter (wac

  15. Calculating Equilibrium Constants in the SnCl2-H2O-NaOH System According to Potentiometric Titration Data

    NASA Astrophysics Data System (ADS)

    Maskaeva, L. N.; Fedorova, E. A.; Yusupov, R. A.; Markov, V. F.

    2018-05-01

    The potentiometric titration of tin chloride SnCl2 is performed in the concentration range of 0.00009-1.1 mol/L with a solution of sodium hydroxide NaOH. According to potentiometric titration data based on modeling equilibria in the SnCl2-H2O-NaOH system, basic equations are generated for the main processes, and instability constants are calculated for the resulting hydroxo complexes and equilibrium constants of low-soluble tin(II) compounds. The data will be of interest for specialists in the field of theory of solutions.

  16. Development of a Platform to Enable Fully Automated Cross-Titration Experiments.

    PubMed

    Cassaday, Jason; Finley, Michael; Squadroni, Brian; Jezequel-Sur, Sylvie; Rauch, Albert; Gajera, Bharti; Uebele, Victor; Hermes, Jeffrey; Zuck, Paul

    2017-04-01

    In the triage of hits from a high-throughput screening campaign or during the optimization of a lead compound, it is relatively routine to test compounds at multiple concentrations to determine potency and maximal effect. Additional follow-up experiments, such as agonist shift, can be quite valuable in ascertaining compound mechanism of action (MOA). However, these experiments require cross-titration of a test compound with the activating ligand of the receptor requiring 100-200 data points, severely limiting the number tested in MOA assays in a screening triage. We describe a process to enhance the throughput of such cross-titration experiments through the integration of Hewlett Packard's D300 digital dispenser onto one of our robotics platforms to enable on-the-fly cross-titration of compounds in a 1536-well plate format. The process handles all the compound management and data tracking, as well as the biological assay. The process relies heavily on in-house-built software and hardware, and uses our proprietary control software for the platform. Using this system, we were able to automate the cross-titration of compounds for both positive and negative allosteric modulators of two different G protein-coupled receptors (GPCRs) using two distinct assay detection formats, IP1 and Ca 2+ detection, on nearly 100 compounds for each target.

  17. A titration method for determining individual oxidant concentration in the dual sodium persulfate and hydrogen peroxide oxidation system.

    PubMed

    Liang, Chenju; He, Boyu

    2018-05-01

    The use of a dual oxidation system, which combines sodium persulfate (Na 2 S 2 O 8 , SPS) and hydrogen peroxide (H 2 O 2 , HP) is increasing as an in-situ chemical oxidation (ISCO) process for soil and groundwater remediation. An analytical method was assessed in this study for determining individual oxidant concentration in order to understand the interactions, and variations in the concentrations, of SPS and HP in aqueous systems containing both SPS and HP. The iodometric titration method was demonstrated to be capable of measuring total oxidant (SPS + HP) concentration; while the ceric sulfate titration method can be used specifically for measuring HP in the dual oxidation system without interfering with the iodometric titration. Therefore, SPS concentration can be deduced by subtraction of the HP concentration from the total oxidant concentration. Direct iodometric titration for determination of total oxidant at concentration above 20 mM exhibited <8% concentration. Based on the results of indirect determination of SPS in the dual oxidation system, an approximate 10% concentration variation was expected. This research may serve as a reference for measuring oxidant variations in this ISCO dual oxidant application. Copyright © 2018. Published by Elsevier Ltd.

  18. Electroconvulsive therapy stimulus titration: Not all it seems.

    PubMed

    Rosenman, Stephen J

    2018-05-01

    To examine the provenance and implications of seizure threshold titration in electroconvulsive therapy. Titration of seizure threshold has become a virtual standard for electroconvulsive therapy. It is justified as individualisation and optimisation of the balance between efficacy and unwanted effects. Present day threshold estimation is significantly different from the 1960 studies of Cronholm and Ottosson that are its usual justification. The present form of threshold estimation is unstable and too uncertain for valid optimisation or individualisation of dose. Threshold stimulation (lowest dose that produces a seizure) has proven therapeutically ineffective, and the multiples applied to threshold to attain efficacy have never been properly investigated or standardised. The therapeutic outcomes of threshold estimation (or its multiples) have not been separated from simple dose effects. Threshold estimation does not optimise dose due to its own uncertainties and the different short-term and long-term cognitive and memory effects. Potential harms of titration have not been examined. Seizure threshold titration in electroconvulsive therapy is not a proven technique of dose optimisation. It is widely held and practiced; its benefit and harmlessness assumed but unproven. It is a prematurely settled answer to an unsettled question that discourages further enquiry. It is an example of how practices, assumed scientific, enter medicine by obscure paths.

  19. A modified two-point titration method for the determination of volatile fatty acids in anaerobic systems.

    PubMed

    Mu, Zhe-Xuan; He, Chuan-Shu; Jiang, Jian-Kai; Zhang, Jie; Yang, Hou-Yun; Mu, Yang

    2018-08-01

    The volatile fatty acids (VFA) concentration plays important roles in the rapid start-up and stable operation of anaerobic reactors. It's essential to develop a simple and accurate method to monitor the VFA concentration in the anaerobic systems. In present work, a modified two-point titration method was developed to determine the VFA concentration. The results show that VFA concentration in standard solutions estimated by the titration method coincided well with that measured by gas chromatograph, where all relative errors were lower than 5.5%. Compared with the phosphate, ammonium and sulfide subsystems, the effect of bicarbonate on the accuracy of the developed method was relatively significant. When the bicarbonate concentration varied from 0 to 8 mmol/L, the relative errors increased from 1.2% to 30% for VFA concentration at 1 mmol/L, but were within 2.0% for that at 5 mmol/L. In addition, the VFA composition affected the accuracy of the titration method to some extent. This developed titration method was further proved to be effective with practical effluents from a lab-scale anaerobic reactor under organic shock loadings and an unstable full-scale anaerobic reactor. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. A Low-Cost Device for Automatic Photometric Titrations

    NASA Astrophysics Data System (ADS)

    Rocha, Fábio R. P.; Reis, Boaventura F.

    2000-02-01

    Electronics is an important topic in chemistry courses. However, the introduction of basic concepts is often difficult and the lab instruments are frequently seen as "black boxes". To address this problem, we propose the construction of a simple, low-cost (about $150 U.S.) automatic photometric titrator employing a light-emitting diode (LED) and a phototransistor. The electronic circuit can be assembled by the students themselves. The device was employed to implement a common procedure in chemical labs, making feasible the introduction of concepts related to electronics in undergraduate chemistry courses. The titrator is able to work automatically, since a feedback system permits stopping the addition of titrant solution when the end-point is achieved. With this demonstration, it can be stressed that automatic procedures can be implemented without expensive instruments. Additionally, a classical procedure becomes more attractive to the students and its importance to chemical analysis can be emphasized. The feasibility of the titrator was demonstrated by acid-base titrations of HCl solutions with NaOH in the presence of phenolphthalein and by iodimetric determination of ascorbic acid in vitamin C tablets and lemon juice. Precise results (0.7% relative standard deviation, n = 10) in agreement at the 95% confidence level with those attained by a conventional procedure were obtained.

  1. A rigorous multiple independent binding site model for determining cell-based equilibrium dissociation constants.

    PubMed

    Drake, Andrew W; Klakamp, Scott L

    2007-01-10

    A new 4-parameter nonlinear equation based on the standard multiple independent binding site model (MIBS) is presented for fitting cell-based ligand titration data in order to calculate the ligand/cell receptor equilibrium dissociation constant and the number of receptors/cell. The most commonly used linear (Scatchard Plot) or nonlinear 2-parameter model (a single binding site model found in commercial programs like Prism(R)) used for analysis of ligand/receptor binding data assumes only the K(D) influences the shape of the titration curve. We demonstrate using simulated data sets that, depending upon the cell surface receptor expression level, the number of cells titrated, and the magnitude of the K(D) being measured, this assumption of always being under K(D)-controlled conditions can be erroneous and can lead to unreliable estimates for the binding parameters. We also compare and contrast the fitting of simulated data sets to the commonly used cell-based binding equation versus our more rigorous 4-parameter nonlinear MIBS model. It is shown through these simulations that the new 4-parameter MIBS model, when used for cell-based titrations under optimal conditions, yields highly accurate estimates of all binding parameters and hence should be the preferred model to fit cell-based experimental nonlinear titration data.

  2. Filtrates & Residues: Olfactory Titration.

    ERIC Educational Resources Information Center

    Wood, John T.; Eddy, Roberta M.

    1996-01-01

    Presents an experiment that uses a unique acid-base indicator--the odor of raw onion--to indicate the end point of the titration of sodium hydroxide with hydrochloric acid. Allows the student to detect the completion of the neutralization reaction by olfaction rather than sight. (JRH)

  3. COPPER COMPLEXATION BY NATURAL ORGANIC MATTER IN CONTAMINATED AND UNCOMTAINATED GROUND WATER

    EPA Science Inventory

    Ground-water samples were collected from an uncontaminated and a contaminated site. Copper complexation was characterized by ion-selective electrode (ISE), fluorescence quenching (FQ), and cathodic stripping voltammetric (CSV) titrations. All of the samples were titrated at their...

  4. CONDUCTOMETRIC CHARACTERIZATION OF DISSOLVED HUMIC MATERIALS. (R828158)

    EPA Science Inventory

    Conductometric replacement titrations of humic and fulvic acids dissolved in a slight excess of hydroxide were carried out with standard acid. The slope of the titration curve corresponding to the protonation of humate/fulvate was related to the electrophoretic mobility of the...

  5. Pilot study of a new device to titrate oxygen flow in hypoxic patients on long-term oxygen therapy.

    PubMed

    Cirio, Serena; Nava, Stefano

    2011-04-01

    The O(2) Flow Regulator (Dima, Bologna, Italy) is a new automated oxygen regulator that titrates the oxygen flow based on a pulse-oximetry signal to maintain a target S(pO(2)). We tested the device's safety and efficacy. We enrolled 18 subjects with chronic lung disease, exercise-induced desaturation, and on long-term oxygen therapy, in a randomized crossover study with 2 constant-work-load 15-min cycling exercise tests, starting with the patient's previously prescribed usual oxygen flow. In one test the oxygen flow was titrated manually by the respiratory therapist, and in the other test the oxygen flow was titrated by the O(2) Flow Regulator, to maintain an S(pO(2)) of 94%. We measured S(pO(2)) throughout each test, the time spent by the respiratory therapist to set the device or to manually regulate the oxygen flow, and the total number of respiratory-therapist titration interventions during the trial. There were no differences in symptoms or heart rate between the exercise tests. Compared to the respiratory-therapist-controlled tests, during the O(2) Flow Regulator tests S(pO(2)) was significantly higher (95 ± 2% vs 93 ± 3%, P = .04), significantly less time was spent below the target S(pO(2)) (171 ± 187 s vs 340 ± 220 s, P < .001), and the O(2) Flow Regulator tests required significantly less respiratory therapist time (5.6 ± 3.7 min vs 2.0 ± 0.1 min, P = .005). The O(2) Flow Regulator may be a safe and effective alternative to manual oxygen titration during exercise in hypoxic patients. It provided stable S(pO(2)) and avoided desaturations in our subjects.

  6. Randomized Trial of Long-Acting Insulin Glargine Titration Web Tool (LTHome) Versus Enhanced Usual Therapy of Glargine Titration (INNOVATE Trial).

    PubMed

    Bajaj, Harpreet S; Venn, Karri; Ye, Chenglin; Aronson, Ronnie

    2016-10-01

    Basal insulin titration in the real world is often unsuccessful. LTHome, a web tool, applies a rules engine-based algorithm providing insulin titration advice directly to the patient. This pilot, randomized trial evaluates basal insulin glargine titration by LTHome compared to enhanced usual therapy ([EUT]-diabetes education program) over 12 weeks. Important inclusion criteria: 18-75 years, type 2 diabetes, computer literacy, and HbA1c >7.0%. Trial protocol was approved by ethics board. We randomized 139 subjects. The achievement of primary composite outcome (four out of seven fasting plasma glucose [FPG] within 5-7.2 mmol/L + mean for three consecutive FPG within 5-7.2 mmol/L + no severe hypoglycemia) was 15% in LTHome versus 41% in EUT (noninferiority not met, P-value = 0.92). Other outcomes were similar between the LTHome and EUT arms: alternate composite outcome achievement (last five FPG mean within the range of 5-7.2 mmol/L + no hypoglycemia, 47% and 51%, P = 0.73); A1c reduction (-1.0% and -1.1%, P = 0.66); proportion achieving A1c ≤7% (14% and 20%, P = 0.36); and hypoglycemia incidence (31% and 37%, P = 0.4), respectively. Patient satisfaction score improvements were greater in LTHome versus EUT (change in fear of hypoglycemia score P = 0.04 and change in diabetes distress score P = 0.04). The mean number of additional healthcare provider visits was 0.13 for LTHome and 1.22 for EUT (P < 0.01). INNOVATE trial suggests clinical utility of LTHome compared to EUT in real-life settings. Further research is needed to evaluate the efficacy and safety of automated insulin titration algorithms.

  7. Equivalence of nasal and oronasal masks during initial CPAP titration for obstructive sleep apnea syndrome.

    PubMed

    Teo, Ming; Amis, Terence; Lee, Sharon; Falland, Karina; Lambert, Stephen; Wheatley, John

    2011-07-01

    Continuous positive airway pressure (CPAP) titration studies are commonly performed using a nasal mask but some patients may prefer a full-face or oronasal mask. There is little evidence regarding the equivalence of different mask interfaces used to initiate treatment. We hypothesized that oronasal breathing when using an oronasal mask increases upper airway collapsibility and that a higher pressure may be required to maintain airway patency. We also assessed patient preferences for the 2 mask interfaces. Prospective, randomized, cross-over design with 2 consecutive CPAP titration nights. Accredited laboratory in a university hospital. Twenty-four treatment-naive subjects with obstructive sleep apnea syndrome and respiratory disturbance index of greater than 15 events per hour. CPAP titration was performed using an auto-titrating machine with randomization to a nasal or oronasal mask, followed by a second titration night using the alternate mask style. There was no significant difference in the mean pressures determined between nasal and oronasal masks, although 43% of subjects had nasal-to-oronasal mask-pressure differences of 2 cm H(2)O or more. Residual respiratory events, arousals, and measured leak were all greater with the oronasal mask. Seventy-nine percent of subjects preferred the nasal mask. Patients with obstructive sleep apnea syndrome can generally switch between nasal and oronasal masks without changing machine pressure, although there are individual differences that may be clinically significant. Measured leak is greater with the oronasal mask. Most patients with obstructive sleep apnea syndrome prefer a nasal mask as the interface for initiation of CPAP. Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN12611000243910. URL: http://www.ANZCTR.org.au/ACTRN12611000243910.aspx

  8. Comparative study of titrated oral misoprostol solution and vaginal dinoprostone for labor induction at term pregnancy.

    PubMed

    Wang, Xiu; Yang, Aijun; Ma, Qingyong; Li, Xuelan; Qin, Li; He, Tongqiang

    2016-09-01

    To evaluate effectiveness and safety of titrated oral misoprostol solution (OMS) in comparison with vaginal dinoprostone for cervix ripening and labor induction in term pregnant women. A multicenter randomized controlled trial of women with term singleton pregnancy with indications for labor induction; 481 participants were allocated to receive titrated OMS with different doses by hourly administration according to the procedure or insert vaginal dinoprostone for cervix ripening and labor induction to compare maternal outcomes including indication of labor induction, mode of outcome of delivery, maternal morbidity, and neonatal outcomes between two groups for evaluating the efficacy and safety of titrated oral misoprostol induction. Proportion of delivery within 12 h of titrated oral misoprostol is significantly less than vaginal dinoprostone (p = 0.03), but no difference of total vaginal delivery rate (p = 0.93); the mean time of first treatment to vaginal delivery was longer in OMS group (21.3 ± 14.5 h) compared with the vaginal dinoprostone group (15.7 ± 9.6 h). Although the proportion of cesarean section between the two groups showed no statistically significant difference, OMS group showed significantly lower frequency of uterine hyperstimulation, hypertonus, partus precipitatus and non-reassuring fetal heart rate than dinoprostone group. Neonatal outcomes were similar evaluating from Apgar score and NICU admission. Our study also showed that labor induction of women with cervix Bishop score ≤3 needed increased dosage of misoprostol solution. Titrated OMS is as effective as vaginal dinoprostone in labor induction for term pregnant women, with safer effect for its lower rate of adverse effect for women.

  9. The influence of graded degrees of chronic hypercapnia on the acute carbon dioxide titration curve

    PubMed Central

    Goldstein, Marc B.; Gennari, F. John; Schwartz, William B.

    1971-01-01

    Studies were carried out to determine the influence of the chronic level of arterial carbon dioxide tension upon the buffering response to acute changes in arterial carbon dioxide tension. After chronic adaptation to six levels of arterial CO2 tension, ranging between 35 and 110 mm Hg, unanesthetized dogs underwent acute whole body CO2 titrations. In each instance a linear relationship was observed between the plasma hydrogen ion concentration and the arterial carbon dioxide tension. Because of this linear relationship, it has been convenient to compare the acute buffering responses among dogs in terms of the slope, dH+/dPaco2. With increasing chronic hypercapnia there was a decrease in this slope, i.e. an improvement in buffer capacity, which is expressed by the equation dH+/dPaco2=-0.005 (Paco2)chronic + 0.95. In effect, the ability to defend pH during acute titration virtually doubled as chronic Paco2 increased from 35 to 110 mm Hg. The change in slope, dH+/dPaco2, was the consequence of the following two factors: the rise in plasma bicarbonate concentration which occurs with chronic hypercapnia of increasing severity, and the greater change in bicarbonate concentration which occurred during the acute CO2 titration in the animals with more severe chronic hypercapnia. These findings demonstrate the importance of the acid-base status before acute titration in determining the character of the carbon dioxide titration curve. They also suggest that a quantitative definition of the interplay between acute and chronic hypercapnia in man should assist in the rational analysis of acid-base disorders in chronic pulmonary insufficiency. PMID:5543876

  10. Decreased rates of hypoglycemia following implementation of a comprehensive computerized insulin order set and titration algorithm in the inpatient setting.

    PubMed

    Sinha Gregory, Naina; Seley, Jane Jeffrie; Gerber, Linda M; Tang, Chin; Brillon, David

    2016-12-01

    More than one-third of hospitalized patients have hyperglycemia. Despite evidence that improving glycemic control leads to better outcomes, achieving recognized targets remains a challenge. The objective of this study was to evaluate the implementation of a computerized insulin order set and titration algorithm on rates of hypoglycemia and overall inpatient glycemic control. A prospective observational study evaluating the impact of a glycemic order set and titration algorithm in an academic medical center in non-critical care medical and surgical inpatients. The initial intervention was hospital-wide implementation of a comprehensive insulin order set. The secondary intervention was initiation of an insulin titration algorithm in two pilot medicine inpatient units. Point of care testing blood glucose reports were analyzed. These reports included rates of hypoglycemia (BG < 70 mg/dL) and hyperglycemia (BG >200 mg/dL in phase 1, BG > 180 mg/dL in phase 2). In the first phase of the study, implementation of the insulin order set was associated with decreased rates of hypoglycemia (1.92% vs 1.61%; p < 0.001) and increased rates of hyperglycemia (24.02% vs 27.27%; p < 0.001) from 2010 to 2011. In the second phase, addition of a titration algorithm was associated with decreased rates of hypoglycemia (2.57% vs 1.82%; p = 0.039) and increased rates of hyperglycemia (31.76% vs 41.33%; p < 0.001) from 2012 to 2013. A comprehensive computerized insulin order set and titration algorithm significantly decreased rates of hypoglycemia. This significant reduction in hypoglycemia was associated with increased rates of hyperglycemia. Hardwiring the algorithm into the electronic medical record may foster adoption.

  11. Design of a multicentre randomized controlled trial to assess the safety and efficacy of dose titration by specialized nurses in patients with heart failure. ETIFIC study protocol

    PubMed Central

    García‐Garrido, LLuisa; Nebot Margalef, Magdalena; Lekuona, Iñaki; Comin‐Colet, Josep; Manito, Nicolás; Roure, Julia; Ruiz Rodriguez, Pilar; Enjuanes, Cristina; Latorre, Pedro; Torcal Laguna, Jesús; García‐Gutiérrez, Susana

    2017-01-01

    Abstract Aims Heart failure (HF) is associated with many hospital admissions and relatively high mortality, rates decreasing with administration of beta‐blockers (BBs), angiotensin‐converting‐enzyme inhibitors, angiotensin II receptor blockers, and mineralocorticoid receptor antagonists. The effect is dose dependent, suboptimal doses being common in clinical practice. The 2012 European guidelines recommend close monitoring and dose titration by HF nurses. Our main aim is to compare BB doses achieved by patients after 4 months in intervention (HF nurse‐managed) and control (cardiologist‐managed) groups. Secondary aims include comparing doses of the other aforementioned drugs achieved after 4 months, adverse events, and outcomes at 6 months in the two groups. Methods We have designed a multicentre (20 hospitals) non‐inferiority randomized controlled trial, including patients with new‐onset HF, left ventricular ejection fraction ≤40%, and New York Heart Association class II–III, with no contraindications to BBs. We will also conduct qualitative analysis to explore potential barriers to and facilitators of dose titration by HF nurses. In the intervention group, HF nurses will implement titration as prescribed by cardiologists, following a protocol. In controls, cardiologists will both prescribe and titrate doses. The study variables are doses of each of the drugs after 4 months relative to the target dose (%), New York Heart Association class, left ventricular ejection fraction, N‐terminal pro B‐type natriuretic peptide levels, 6 min walk distance, comorbidities, renal function, readmissions, mortality, quality of life, and psychosocial characteristics. Conclusions The trial seeks to assess whether titration by HF nurses of drugs recommended in practice guidelines is safe and not inferior to direct management by cardiologists. The results could have an impact on clinical practice. PMID:29154427

  12. Feasibility and Association of Neurohumoral Blocker Up-titration After Cardiac Resynchronization Therapy.

    PubMed

    Martens, Pieter; Verbrugge, Frederik H; Nijst, Petra; Bertrand, Philippe B; Dupont, Matthias; Tang, Wilson H; Mullens, Wilfried

    2017-08-01

    Cardiac resynchronization therapy (CRT) improves mortality and morbidity on top of optimal medical therapy in heart failure with reduced ejection fraction (HFrEF). This study aimed to elucidate the association between neurohumoral blocker up-titration after CRT implantation and clinical outcomes. Doses of angiotensin-converting enzyme inhibitors (ACE-Is), angiotensin receptor blockers (ARBs), and beta-blockers were retrospectively evaluated in 650 consecutive CRT patients implanted from October 2008 to August 2015 and followed in a tertiary multidisciplinary CRT clinic. All 650 CRT patients were on a maximal tolerable dose of ACE-I/ARB and beta-blocker at the time of CRT implantation. However, further up-titration was successful in 45.4% for ACE-I/ARB and in 56.8% for beta-blocker after CRT-implantation. During a mean follow-up of 37 ± 22 months, a total of 139 events occurred for the combined end point of heart failure admission and all-cause mortality. Successful, versus unsuccessful, up-titration was associated with adjusted hazard ratios of 0.537 (95% confidence interval 0.316-0.913; P = .022) for ACE-I/ARB and 0.633 (0.406-0.988; P = .044) for beta-blocker on the combined end point heart failure admission and all-cause mortality. Patients in the up-titration group exhibited a similar risk for death or heart failure admission as patients treated with the maximal dose (ACE-I/ARB: P = .133; beta-blockers: P = .709). After CRT, a majority of patients are capable of tolerating higher dosages of neurohumoral blockers. Up-titration of neurohumoral blockers after CRT implantation is associated with improved clinical outcomes, similarly to patients treated with the guideline-recommended target dose at the time of CRT implantation. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Consensus on Insulin Dose and Titration Algorithms in Ambulatory Care of Type 2 Diabetes in India.

    PubMed

    Kovil, Rajiv; Chawla, Manoj; Rajput, Rajesh; Singh, A K; Sinha, Binayak; Ghosal, Samit; Ballani, Piya; Gupta, Sunil; Tanna, Snehal; Bandukwala, S M; Shah, Tejas; Negalur, Vijay; Bhoraskar, Anil; Aravind, S R; Zargar, Abdul H; Kesavadev, Jothydev; Das, Ashok Kumar

    2017-02-01

    Insulin is the oldest of the currently available treatment options in Type 2 diabetes mellitus (T2DM) and is considered as the most effective glucose lowering agent. Despite this, decision on starting insulin therapy is often delayed in India as well as worldwide due to various barriers at both patient and physician levels. Appropriate insulin dosing and titration is also critical to the successful achievement of tight glycaemic control. To provide simple and easily implementable guidelines to primary care physicians on appropriate insulin dosing and titration of various insulin regimens for both initiation and intensification. Each insulin regimen (once daily [OD] basal, OD, twice daily and thrice daily premixed, basal-plus and basal-bolus) was presented and evaluated for dosing and titration based on established guidelines, data from approved pack inserts, and published scientific literature. These evaluations were then factored into the national context based on the expert committee representatives patient-physician experience in their clinical practice and common therapeutic practices followed in India. Recommendations for dosing and titration of basal, basal-plus, premixed and basal-bolus insulins were developed. The key recommendations are that insulin doses can be adjusted once or twice weekly; adjustment can be based on lowest/mean of three recent self-monitoring of plasma glucose pre-meal/fasting plasma glucose (FPG) values. The titration should be based on FPG or pre-meal value of 80-130 mg/dL and the dose should be reduced by 10-20% for patients reporting hypoglycaemia(<70mg/dL). The consensus based recommendations mentioned in this paper will be a useful reference tool for health care practitioners, to initiate, optimise and intensify insulin therapy and to successfully achieve optimal glucose control.

  14. Aquaporin-4 antibody titration in NMO patients treated with rituximab: A retrospective study.

    PubMed

    Valentino, Paola; Marnetto, Fabiana; Granieri, Letizia; Capobianco, Marco; Bertolotto, Antonio

    2017-03-01

    We undertook an observational retrospective study to investigate the usefulness of aquaporin-4 (AQP4) antibodies (Ab) titration in the management of patients with neuromyelitis optica (NMO) treated with rituximab (RTX) by studying (1) the correlation between AQP4-Ab titer and disease activity, (2) the influence of RTX on antibody levels, and (3) the association between AQP4-Ab levels and responsiveness to RTX. A cell-based assay was used for AQP4-Ab titration in 322 serum samples from 7 patients with NMO treated with RTX (median follow-up 65 months), according to a treatment-to-target approach. Serum samples were collected every month following standardized procedures. (1) In group analysis, AQP4-Ab titers correlated with the disease activity, showing higher titers during and preceding relapses than during remission. However, in individual analysis, an increase in AQP4-Ab titers and CD19+ B cells did not always precede a relapse. (2) A reduction of AQP4-Ab titers in the short-term and long-term period was observed during RTX treatment. (3) Reduction of AQP4-Ab titers was observed in responder patients both 3 months after RTX infusion and in the long-term follow-up. In one nonresponder patient, AQP4-Ab levels never decreased during the treatment period. Titration of AQP4-Abs could be useful in the clinical management of patients with NMO treated with RTX: titration before each reinfusion and 3 months after each reinfusion may provide information about responsiveness to RTX. Although a relationship among AQP4-Ab levels, disease activity, and response to RTX was observed, the usefulness of AQP4-Ab titration to predict relapses is limited.

  15. Effect of Levodopa-carbidopa Intestinal Gel on Non-motor Symptoms in Patients with Advanced Parkinson's Disease.

    PubMed

    Standaert, David G; Rodriguez, Ramon L; Slevin, John T; Lobatz, Michael; Eaton, Susan; Chatamra, Krai; Facheris, Maurizio F; Hall, Coleen; Sail, Kavita; Jalundhwala, Yash J; Benesh, Janet

    2017-01-01

    Levodopa-carbidopa intestinal gel (LCIG; carbidopa-levodopa enteral suspension in the United States), delivered via percutaneous gastrojejunostomy (PEG-J) and titrated in the inpatient setting, is an established treatment option for advanced Parkinson's disease (PD) patients with motor fluctuations. However, long-term prospective data on the efficacy of LCIG on non-motor symptoms and the safety of outpatient titration are limited. In this 60-week, open-label phase 3b study, LCIG titration was initiated in an outpatient setting following PEG-J placement in PD patients. The efficacy of LCIG on motor and non-motor symptoms, quality of life, and safety was assessed. Thirty-nine patients were enrolled in the study and 28 patients completed the treatment. A majority of patients (54%) completed outpatient titration within the first week of LCIG infusion. LCIG led to significant reductions from baseline in Non-Motor Symptom Scale (NMSS) total score (least squares mean ± SE = -17.6 ± 3.6, P < 0.001) and 6 of the NMSS domain scores (sleep/fatigue, attention/memory, gastrointestinal tract, urinary, sexual function, miscellaneous) at week 12. These reductions were maintained at week 60 with the exception of the urinary domain. "Off" time (-4.9 ± 0.5 hours/day, P < 0.001) and "On" time without troublesome dyskinesia (-4.3 ± 0.6 hours/day, P < 0.001) were improved at week 60. Adverse events (AEs) were reported in 37 (95%) patients. LCIG treatment led to reductions in non-motor symptom burden and motor fluctuations in advanced PD patients. The safety profile was consistent with previous studies that used inpatient titration and outpatient titration did not appear to pose additional risk.

  16. Effect of temperature on the acid-base properties of the alumina surface: microcalorimetry and acid-base titration experiments.

    PubMed

    Morel, Jean-Pierre; Marmier, Nicolas; Hurel, Charlotte; Morel-Desrosiers, Nicole

    2006-06-15

    Sorption reactions on natural or synthetic materials that can attenuate the migration of pollutants in the geosphere could be affected by temperature variations. Nevertheless, most of the theoretical models describing sorption reactions are at 25 degrees C. To check these models at different temperatures, experimental data such as the enthalpies of sorption are thus required. Highly sensitive microcalorimeters can now be used to determine the heat effects accompanying the sorption of radionuclides on oxide-water interfaces, but enthalpies of sorption cannot be extracted from microcalorimetric data without a clear knowledge of the thermodynamics of protonation and deprotonation of the oxide surface. However, the values reported in the literature show large discrepancies and one must conclude that, amazingly, this fundamental problem of proton binding is not yet resolved. We have thus undertaken to measure by titration microcalorimetry the heat effects accompanying proton exchange at the alumina-water interface at 25 degrees C. Based on (i) the surface sites speciation provided by a surface complexation model (built from acid-base titrations at 25 degrees C) and (ii) results of the microcalorimetric experiments, calculations have been made to extract the enthalpic variations associated respectively to first and second deprotonation of the alumina surface. Values obtained are deltaH1 = 80+/-10 kJ mol(-1) and deltaH2 = 5+/-3 kJ mol(-1). In a second step, these enthalpy values were used to calculate the alumina surface acidity constants at 50 degrees C via the van't Hoff equation. Then a theoretical titration curve at 50 degrees C was calculated and compared to the experimental alumina surface titration curve. Good agreement between the predicted acid-base titration curve and the experimental one was observed.

  17. Evaluation of modified boehm titration methods for use with biochars.

    PubMed

    Fidel, Rivka B; Laird, David A; Thompson, Michael L

    2013-11-01

    The Boehm titration, originally developed to quantify organic functional groups of carbon blacks and activated carbons in discrete pK ranges, has received growing attention for analyzing biochar. However, properties that distinguish biochar from carbon black and activated carbon, including greater carbon solubility and higher ash content, may render the original Boehm titration method unreliable for use with biochars. Here we use seven biochars and one reference carbon black to evaluate three Boehm titration methods that use (i) acidification followed by sparging (sparge method), (ii) centrifugation after treatment with BaCl (barium method), and (iii) a solid-phase extraction cartridge followed by acidification and sparging (cartridge method) to remove carbonates and dissolved organic compounds (DOC) from the Boehm extracts before titration. Our results for the various combinations of Boehm reactants and methods indicate that no one method was free of bias for all three Boehm reactants and that the cartridge method showed evidence of bias for all pK ranges. By process of elimination, we found that a combination of the sparge method for quantifying functional groups in the lowest pK range (∼5 to 6.4), and the barium method for quantifying functional groups in the higher pK ranges (∼6.4 to 10.3 and ∼10.3 to 13) to be free of evidence for bias. We caution, however, that further testing is needed and that all Boehm titration results for biochars should be considered suspect unless efforts were undertaken to remove ash and prevent interference from DOC. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  18. Surfactant titration of nanoparticle-protein corona.

    PubMed

    Maiolo, Daniele; Bergese, Paolo; Mahon, Eugene; Dawson, Kenneth A; Monopoli, Marco P

    2014-12-16

    Nanoparticles (NP), when exposed to biological fluids, are coated by specific proteins that form the so-called protein corona. While some adsorbing proteins exchange with the surroundings on a short time scale, described as a "dynamic" corona, others with higher affinity and long-lived interaction with the NP surface form a "hard" corona (HC), which is believed to mediate NP interaction with cellular machineries. In-depth NP protein corona characterization is therefore a necessary step in understanding the relationship between surface layer structure and biological outcomes. In the present work, we evaluate the protein composition and stability over time and we systematically challenge the formed complexes with surfactants. Each challenge is characterized through different physicochemical measurements (dynamic light scattering, ζ-potential, and differential centrifugal sedimentation) alongside proteomic evaluation in titration type experiments (surfactant titration). 100 nm silicon oxide (Si) and 100 nm carboxylated polystyrene (PS-COOH) NPs cloaked by human plasma HC were titrated with 3-[(3-Cholamidopropyl) dimethylammonio]-1-propanesulfonate (CHAPS, zwitterionic), Triton X-100 (nonionic), sodium dodecyl sulfate (SDS, anionic), and dodecyltrimethylammonium bromide (DTAB, cationic) surfactants. Composition and density of HC together with size and ζ-potential of NP-HC complexes were tracked at each step after surfactant titration. Results on Si NP-HC complexes showed that SDS removes most of the HC, while DTAB induces NP agglomeration. Analogous results were obtained for PS NP-HC complexes. Interestingly, CHAPS and Triton X-100, thanks to similar surface binding preferences, enable selective extraction of apolipoprotein AI (ApoAI) from Si NP hard coronas, leaving unaltered the dispersion physicochemical properties. These findings indicate that surfactant titration can enable the study of NP-HC stability through surfactant variation and also selective separation of certain proteins from the HC. This approach thus has an immediate analytical value as well as potential applications in HC engineering.

  19. Titrating Oxygen Requirements During Exercise: Evaluation of a Standardized Single Walk Test Protocol.

    PubMed

    Giovacchini, Coral X; Mathews, Anne M; Lawlor, Brian R; MacIntyre, Neil R

    2018-04-01

    Oxygen supplementation for exercise-induced hypoxemia is a common clinical practice that improves exercise tolerance. However, we know of no standardized exercise oxygen titration protocol using a single walk test. We report our experience with a protocol developed in our laboratory. Our protocol is based on the 6-min walk test (6MWT). Pulse oximetry readings (oxygen saturation [Spo 2 ]) are monitored, and supplemental oxygen is added in 2 L/min increments to keep Spo 2 > 88%. This continues for at least 6 min of walking with the Spo 2 remaining > 88% for at least 3 min. The records of consecutive patients over 4 months undergoing this procedure were reviewed for test performance, oxygen titration results, and adverse events. Two hundred twenty-two patients were tested; only two prematurely terminated the protocol because of intractable dyspnea. One hundred fifty-six patients (38%) required oxygen supplementation, with the first titration most commonly occurring between 1 and 2 min of walking. Nine of the patients had the first titration after 5 min of walking. The average test duration was 7 min (maximum, 15 min). The average number of titrations was 2.2 (maximum six). Sixteen patients could not maintain Spo 2 > 88% for 3 min despite administration of 15 L/min of supplemental oxygen (maximal dose). Our protocol was easily performed as a modification of a standard 6MWT with no serious adverse events. Because it is based on a widely accepted measurement of functional capabilities, and because it determined a stable final oxygen dose for ≥ 3 min of walking in most patients, we believe this protocol can be easily adapted for clinical use. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  20. Acid-Base Titration Curves of Soils from a Low-Centered Polygon, Barrow, Alaska, 2013

    DOE Data Explorer

    Jianqiu Zheng; David Graham

    2017-12-05

    This dataset provides pH titration data of soils from a low-centered polygon center. The soil core was collected in 2013 from a low-centered polygon center from the NGEE-Arctic Intensive Study Site 1, Barrow, Alaska.

  1. Effect of Spatial Titration on Task Performance

    ERIC Educational Resources Information Center

    Glowacki, Lawrence

    1976-01-01

    A reinforcement schedule and spatial titration method were used to determine task-reinforcement area separation most preferred and effective in two third-grade boys. Errors in task performance decreased task-reinforcement area separation, while correct responses in task performance increased task-reinforcement area separation. (Author)

  2. Titration of Monoprotic Acids with Sodium Hydroxide Contaminated by Sodium Carbonate.

    ERIC Educational Resources Information Center

    Michalowski, Tadeusz

    1988-01-01

    Discusses the effects of using carbon dioxide contaminated sodium hydroxide solution as a titrant for a solution of a weak monoprotic acid and the resulting distortion of the titration curve in comparison to one obtained when an uncontaminated titrant is used. (CW)

  3. Avian influenza virus isolation, propagation and titration in embryonated chicken eggs

    USDA-ARS?s Scientific Manuscript database

    Avian influenza (AI) virus is usually isolated, propagated, and titrated in embryonated chickens eggs (ECE). Most any sample type can be accommodated for culture with appropriate processing. Isolation may also be accomplished in cell culture particularly if mammalian lineage isolates are suspected, ...

  4. Statistical mechanical model of coupled transcription from multiple promoters due to transcription factor titration

    PubMed Central

    Rydenfelt, Mattias; Cox, Robert Sidney; Garcia, Hernan; Phillips, Rob

    2014-01-01

    Transcription factors (TFs) with regulatory action at multiple promoter targets is the rule rather than the exception, with examples ranging from the cAMP receptor protein (CRP) in E. coli that regulates hundreds of different genes simultaneously to situations involving multiple copies of the same gene, such as plasmids, retrotransposons, or highly replicated viral DNA. When the number of TFs heavily exceeds the number of binding sites, TF binding to each promoter can be regarded as independent. However, when the number of TF molecules is comparable to the number of binding sites, TF titration will result in correlation (“promoter entanglement”) between transcription of different genes. We develop a statistical mechanical model which takes the TF titration effect into account and use it to predict both the level of gene expression for a general set of promoters and the resulting correlation in transcription rates of different genes. Our results show that the TF titration effect could be important for understanding gene expression in many regulatory settings. PMID:24580252

  5. Small-volume potentiometric titrations: EPR investigations of Fe-S cluster N2 in mitochondrial complex I.

    PubMed

    Wright, John J; Salvadori, Enrico; Bridges, Hannah R; Hirst, Judy; Roessler, Maxie M

    2016-09-01

    EPR-based potentiometric titrations are a well-established method for determining the reduction potentials of cofactors in large and complex proteins with at least one EPR-active state. However, such titrations require large amounts of protein. Here, we report a new method that requires an order of magnitude less protein than previously described methods, and that provides EPR samples suitable for measurements at both X- and Q-band microwave frequencies. We demonstrate our method by determining the reduction potential of the terminal [4Fe-4S] cluster (N2) in the intramolecular electron-transfer relay in mammalian respiratory complex I. The value determined by our method, E m7 =-158mV, is precise, reproducible, and consistent with previously reported values. Our small-volume potentiometric titration method will facilitate detailed investigations of EPR-active centres in non-abundant and refractory proteins that can only be prepared in small quantities. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Determination of the total acidity in soft drinks using potentiometric sequential injection titration.

    PubMed

    van Staden, J Koos F; Mashamba, M Mulalo G; Stefan, R Raluca I

    2002-12-06

    A potentiometric SI titration system for the determination of total acidity in soft drinks is proposed. The concept is based on the aspiration of the acid soft drink sample between two base zones into a holding coil with the volume of the first base zone twice to that of the second one and channelled by flow reversal through a reaction coil to a potentiometric sensor. A solution of 0.1 mol l(-1) sodium chloride is used as ionic strength adjustment buffer in the carrier stream. The system has been applied to the analysis of some South African soft drinks having a total acidity level of about 0.2-0.3% (w/v). The method has a sample frequency of 45 samples per h with a linear range of 0.1 and 0.6% (w/v). It is easy to use, fully computerised, and gives the results that are comparable to both automated batch titration and manual titration.

  7. A new sensor for thermometric titrations.

    PubMed

    Najib, Fadhil M; Zewar, Sardir; Abdulla, Ahmad M

    2007-01-15

    A new thermometric sensor, which is a transistor (OC71), has been introduced to follow thermometric titrations successfully to clear end points. The sensor was suitable in both normal and differential modes of titration. It is possible to titrate down to 1.32micromol of HCl and 26.4micromol of H(3)BO(3)in a final 20ml solution with accuracy and precision of 1%, 2.2% and 1.4%, 2.2%, respectively. The sensor, in association with a pH glass electrode, was used for the determination of pK values of some well established weak acids such as, acetic acid (4.77), phosphoric acid (pK(1)=2.18, pK(2)=7.20 and pK(3)=12.32) as well as for a very weak acid of uncertain pK values H(3)BO(3) (pK(1)=9.20, pK(2)=12.7 and pK(3)=13.80). The sensor was also examined for kinetic catalytic determination of iron(III) in water, milk and pharmaceuticals.

  8. Catalytic thermometric titrations in non-aqueous solvents by coulometrically generated titrant.

    PubMed

    Vajgand, V J; Gaál, F F; Brusin, S S

    1970-05-01

    Catalytic thermometric titrations have been developed for tertiary amines and salts of organic acids in acetic and propionic anhydride with titrant coulometrically generated at a mercury and/or platinum anode, hydroquinone being added to the solution titrated if the platinum anode is used. The results obtained are compared with those obtained by coulometric titration with the end-point detected either photometrically or potentiometrically. On a élaboré des titrages thermométriques catalytiques pour les amines tertiaires et les sels d'acides organiques en anhydrides aétique et propionique avec l'agent de titrage engendré coulométriquement sur une anode de mercure et/ou platine, de l'hydroquinone étant ajoutée à la solution titrée si l'on emploie l'anode de platine. Les résultats obtenus sont comparés avec ceux obtenus par titrage coulométrique avec le point de fin de réaction détecté soit photométriquement soit potentioétriquement.

  9. New approach in the treatment of data from an acid-base potentiometric titrationI. Monocomponent systems of monofunctional acids and bases.

    PubMed

    Maslarska, Vania; Tencheva, Jasmina; Budevsky, Omortag

    2003-01-01

    Based on precise analysis of the acid-base equilibrium, a new approach in the treatment of experimental data from a potentiometric titration is proposed. A new general formula giving explicitly the relation V=f([H(+)]) is derived, valid for every acid-base titration, which includes mono- and polyfunctional protolytes and their mixtures. The present study is the first practical application of this formula for the simplest case, the analysis of one monofunctional protolyte. The collected mV data during the titration are converted into pH-values by means of an auto pH-calibration procedure, thus avoiding preliminary preparation of the measuring system. The mentioned pH-calibration method is applicable also in water-organic mixtures and allows the quantitative determination of sparingly soluble substances (particularly pharmaceuticals). The treatment of the data is performed by means of ready-to-use software products, which makes the proposed approach accessible for a wide range of applications.

  10. Spectroscopic study on variations in illite surface properties after acid-base titration.

    PubMed

    Liu, Wen-xin; Coveney, R M; Tang, Hong-xiao

    2003-07-01

    FT-IR, Raman microscopy, XRD, 29Si and 27Al MAS NMR, were used to investigate changes in surface properties of a natural illite sample after acid-base potentiometric titration. The characteristic XRD lines indicated the presence of surface Al-Si complexes, preferable to Al(OH)3 precipitates. In the microscopic Raman spectra, the vibration peaks of Si-O and Al-O bonds diminished as a result of treatment with acid, then increased after hydroxide back titration. The varied ratio of signal intensity between (IV)Al and (VI)Al species in 27Al MAS NMR spectra, together with the stable BET surface area after acidimetric titration, suggested that edge faces and basal planes in the layer structure of illite participated in dissolution of structural components. The combined spectroscopic evidence demonstrated that the reactions between illite surfaces and acid-leaching silicic acid and aluminum ions should be considered in the model description of surface acid-base properties of the aqueous illite.

  11. Ionization behavior of polyphosphoinositides determined via the preparation of pH titration curves using solid-state 31P NMR.

    PubMed

    Graber, Zachary T; Kooijman, Edgar E

    2013-01-01

    Detailed knowledge of the degree of ionization of lipid titratable groups is important for the evaluation of protein-lipid and lipid-lipid interactions. The degree of ionization is commonly evaluated by acid-base titration, but for lipids localized in a multicomponent membrane interface this is not a suitable technique. For phosphomonoester-containing lipids such as the polyphosphoinositides, phosphatidic acid, and ceramide-1-phosphate, this is more conveniently accomplished by (31)P NMR. Here, we describe a solid-state (31)P NMR procedure to construct pH titration curves to determine the degree of ionization of phosphomonoester groups in polyphosphoinositides. This procedure can also be used, with suitable sample preparation conditions, for other important signaling lipids. Access to a solid-state, i.e., magic angle spinning, capable NMR spectrometer is assumed. The procedures described here are valid for a Bruker instrument, but can be adapted for other spectrometers as needed.

  12. Spasmodic dysphonia: a seven-year audit of dose titration and demographics in the Indian population.

    PubMed

    Nerurkar, N K; Banu, T P

    2014-07-01

    This study aimed to evaluate the demographics of spasmodic dysphonia in the Indian population and to analyse the optimum dose titration of botulinum toxin type A in this group. A comparative analysis with international studies was also performed. The study involved a retrospective analysis and audit of botulinum toxin type A dose titration in spasmodic dysphonia patients who visited our voice clinic between January 2005 and January 2012. The average total therapeutic dose required for patients with adductor spasmodic dysphonia was 4.2 U per patient per vocal fold (total 8.4 U per patient), and for patients with abductor spasmodic dysphonia, it was 4.6 U per patient. Our audit revealed that 80 per cent of the spasmodic dysphonia patients were male, which contrasts dramatically with international studies, wherein around 80 per cent of spasmodic dysphonia patients were female. Our study also revealed a higher dose titration of botulinum toxin for the Indian spasmodic dysphonia population in both adductor and abductor spasmodic dysphonia cases.

  13. The SimpleMix study with biphasic insulin aspart 30: a randomized controlled trial investigating patient-driven titration versus investigator-driven titration.

    PubMed

    Gao, Yan; Luquez, Cecilia; Lynggaard, Helle; Andersen, Henning; Saboo, Banshi

    2014-12-01

    The study aimed to confirm the efficacy, through non-inferiority, of patient-driven versus investigator-driven titration of biphasic insulin aspart 30 (BIAsp 30) in terms of glycemic control assessed by HbA1c change. SimpleMix was a 20 week, open-label, randomized, two-armed, parallel-group, multicenter study in five countries (Argentina, China, India, Poland, and the UK). Patients with type 2 diabetes were randomized into either patient-driven or investigator-driven BIAsp 30 titration groups. Non-inferiority of patient-driven vs. investigator-driven titration based on change in HbA1c from baseline to week 20 could not be demonstrated. Mean (SE) estimated change from baseline to week 20 was -0.72 (0.08)% in the patient-driven group and -0.97 (0.08)% in the investigator-driven group; estimated difference 0.25% (95% CI: 0.04; 0.46). Estimated mean change (SE) in fasting plasma glucose from baseline to week 20 was similar between groups: -0.94 (0.21) mmol/L for patient-driven and -1.07 (0.22) mmol/L for investigator-driven (difference non-significant). Both treatment arms were well tolerated, and hypoglycemic episode rates were similar between groups, with a rate ratio of 0.77 (95% CI: 0.54; 1.09; p = 0.143) for all hypoglycemic episodes and 0.78 (95% CI: 0.42; 1.43; p = 0.417) for nocturnal hypoglycemic episodes. Non-inferiority of patient-driven versus investigator-driven titration with regard to change from baseline to end-of-treatment HbA1c could not be confirmed. It is possible that a clinic visit 12 weeks after intensification of treatment with BIAsp 30 in patients with type 2 diabetes inadequately treated with basal insulin may benefit patient-driven titration of BIAsp 30. A limitation of the study was the relatively small number of patients recruited in each country, which does not allow country-specific analyses to be performed. Overall, treatment with BIAsp 30 was well tolerated in both treatment groups.

  14. A randomized titrate-to-target study comparing fixed-dose combinations of azilsartan medoxomil and chlorthalidone with olmesartan and hydrochlorothiazide in stage-2 systolic hypertension.

    PubMed

    Cushman, William C; Bakris, George L; White, William B; Weber, Michael A; Sica, Domenic; Roberts, Andrew; Lloyd, Eric; Kupfer, Stuart

    2018-04-01

    Azilsartan medoxomil (AZL-M), an angiotensin II receptor blocker, has been developed in fixed-dose combinations (FDCs) with chlorthalidone (CTD). We compared FDCs of AZL-M/CTD 20/12.5 mg once daily titrated to 40/25 mg if needed or AZL-M/CTD 40/12.5 mg once daily titrated to 80/25 mg if needed with an olmesartan medoxomil (OLM)-hydrochlorothiazide (HCTZ) 20/12.5 mg FDC once daily titrated to 40/25 mg if needed in a randomized, double-blind, 8-week study of 1085 participants with clinic SBP 160-190 mmHg and DBP 119 mmHg or less. Titration to higher doses occurred at week 4 if BP was at least 140/90 mmHg (≥130/80 mmHg if diabetes or chronic kidney disease). The primary endpoint was change from baseline in clinic SBP; 24-h ambulatory BP monitoring was also measured. Greater reductions in clinic SBP from a baseline of 165 mmHg were observed (P < 0.001) in both AZL-M/CTD arms (-37.6 and -38.2 mmHg) versus OLM/HCTZ (-31.5 mmHg), despite greater dose titration in the OLM/HCTZ group. At 8 weeks, both AZL-M/CTD FDCs reduced 24-h SBP more than OLM/HCTZ (-26.4 and -27.9 versus -20.7 mmHg; both P < 0.001), and higher proportions in both AZL-M/CTD groups achieved target BP compared with the OLM/HCTZ group (69.4 and 68.9 versus 54.7%, both P < 0.001). Adverse events leading to drug discontinuation occurred in 6.2, 9.5, and 3.1% with the AZL-M/CTD lower and higher doses, and OLM/HCTZ, respectively. This large, titration-to-target BP study demonstrated AZL-M/CTD FDCs to have superior antihypertensive efficacy compared with the maximum approved dose of OLM/HCTZ.

  15. A randomized titrate-to-target study comparing fixed-dose combinations of azilsartan medoxomil and chlorthalidone with olmesartan and hydrochlorothiazide in stage-2 systolic hypertension

    PubMed Central

    Cushman, William C.; Bakris, George L.; White, William B.; Weber, Michael A.; Sica, Domenic; Roberts, Andrew; Lloyd, Eric; Kupfer, Stuart

    2018-01-01

    Background: Azilsartan medoxomil (AZL-M), an angiotensin II receptor blocker, has been developed in fixed-dose combinations (FDCs) with chlorthalidone (CTD). Objective/methods: We compared FDCs of AZL-M/CTD 20/12.5 mg once daily titrated to 40/25 mg if needed or AZL-M/CTD 40/12.5 mg once daily titrated to 80/25 mg if needed with an olmesartan medoxomil (OLM)-hydrochlorothiazide (HCTZ) 20/12.5 mg FDC once daily titrated to 40/25 mg if needed in a randomized, double-blind, 8-week study of 1085 participants with clinic SBP 160–190 mmHg and DBP 119 mmHg or less. Titration to higher doses occurred at week 4 if BP was at least 140/90 mmHg (≥130/80 mmHg if diabetes or chronic kidney disease). The primary endpoint was change from baseline in clinic SBP; 24-h ambulatory BP monitoring was also measured. Results: Greater reductions in clinic SBP from a baseline of 165 mmHg were observed (P < 0.001) in both AZL-M/CTD arms (−37.6 and −38.2 mmHg) versus OLM/HCTZ (−31.5 mmHg), despite greater dose titration in the OLM/HCTZ group. At 8 weeks, both AZL-M/CTD FDCs reduced 24-h SBP more than OLM/HCTZ (−26.4 and −27.9 versus −20.7 mmHg; both P < 0.001), and higher proportions in both AZL-M/CTD groups achieved target BP compared with the OLM/HCTZ group (69.4 and 68.9 versus 54.7%, both P < 0.001). Adverse events leading to drug discontinuation occurred in 6.2, 9.5, and 3.1% with the AZL-M/CTD lower and higher doses, and OLM/HCTZ, respectively. Conclusion: This large, titration-to-target BP study demonstrated AZL-M/CTD FDCs to have superior antihypertensive efficacy compared with the maximum approved dose of OLM/HCTZ. PMID:29334491

  16. Determination of chlorine in silicate rocks

    USGS Publications Warehouse

    Peck, L.C.

    1959-01-01

    In a rapid accurate method for the determination of chlorine in silicate rocks, the rock powder is sintered with a sodium carbonate flux containing zinc oxide and magnesium carbonate. The sinter cake is leached with water, the resulting solution is filtered, and the filtrate is acidified with nitric acid. Chlorine is determined by titrating this solution with mercuric nitrate solution using sodium nitroprusside as the indicator. The titration is made in the dark with a beam of light shining through the solution. The end point of the titration is found by visually comparing the intensity of this beam of light with that of a similar beam of light in a reference solution.

  17. Isothermal Titration Calorimetry Can Provide Critical Thinking Opportunities

    ERIC Educational Resources Information Center

    Moore, Dale E.; Goode, David R.; Seney, Caryn S.; Boatwright, Jennifer M.

    2016-01-01

    College chemistry faculties might not have considered including isothermal titration calorimetry (ITC) in their majors' curriculum because experimental data from this instrumental method are often analyzed via automation (software). However, the software-based data analysis can be replaced with a spreadsheet-based analysis that is readily…

  18. Subsite binding energies of an exo-polygalacturonase using isothermal titration calorimetry

    USDA-ARS?s Scientific Manuscript database

    Thermodynamic parameters for binding of a series of galacturonic acid oligomers to an exo-polygalacturonase, RPG16 from Rhizopus oryzae, were determined by isothermal titration calorimetry. Binding of oligomers varying in chain length from two to five galacturonic acid residues is an exothermic proc...

  19. Titration of individual strains in trivalent live-attenuated influenza vaccine without neutralization.

    PubMed

    Sirinonthanawech, Naraporn; Surichan, Somchaiya; Namsai, Aphinya; Puthavathana, Pilaipan; Auewarakul, Prasert; Kongchanagul, Alita

    2016-11-01

    Formulation and quality control of trivalent live-attenuated influenza vaccine requires titration of infectivity of individual strains in the trivalent mix. This is usually performed by selective neutralization of two of the three strains and titration of the un-neutralized strain in cell culture or embryonated eggs. This procedure requires standard sera with high neutralizing titer against each of the three strains. Obtaining standard sera, which can specifically neutralize only the corresponding strain of influenza viruses and is able to completely neutralize high concentration of virus in the vaccine samples, can be a problem for many vaccine manufacturers as vaccine stocks usually have very high viral titers and complete neutralization may not be obtained. Here an alternative approach for titration of individual strain in trivalent vaccine without the selective neutralization is presented. This was done by detecting individual strains with specific antibodies in an end-point titration of a trivalent vaccine in cell culture. Similar titers were observed in monovalent and trivalent vaccines for influenza A H3N2 and influenza B strains, whereas the influenza A H1N1 strain did not grow well in cell culture. Viral interference among the vaccine strains was not observed. Therefore, providing that vaccine strains grow well in cell culture, this assay can reliably determine the potency of individual strains in trivalent live-attenuated influenza vaccines. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Preliminary findings on the correlation of saliva pH, buffering capacity, flow rate and consistency in relation to waterpipe tobacco smoking.

    PubMed

    Khemiss, Mehdi; Ben Khelifa, Mohamed; Ben Saad, Helmi

    2017-12-01

    The aim of the present comparative study was to compare some salivary characteristics between exclusive waterpipe smokers (EWPS) and non-smokers. 72 males (36 EWPS) were recruited. The volume of stimulated saliva was determined and divided by the duration of saliva collection. The pH was measured directly using a pH meter. The buffering capacity was determined using a quantitative method which involved the addition of 10 µl HCl. Up to a total of 160 µL was titrated up to obtain a pH titration curve. At 50 µL of titrated HCl, buffering capacity was ranked into three categories: high, medium and low. EWPS and non-smoker groups had similar flow rates (1.81 ± 0.79 and 1.78 ± 1.14 mL min-1) and similar baseline pH (6.60 ± 0.37 and 6.76 ± 0.39). Statistically significant differences in the two groups' pH were observed from 30 to 160 µL of titrated up HCl. At 50 µL of titrated up HCl, the EWPS group compared to the non-smoker group had a significantly higher pH (4.79 ± 0.72 vs. 5.32 ± 0.79). To conclude, waterpipe tobacco smoking alters the buffering capacity but does not alter either salivary flow rates or the baseline pH and consistency.

  1. Simulation-Based Evaluation of Dose-Titration Algorithms for Rapid-Acting Insulin in Subjects with Type 2 Diabetes Mellitus Inadequately Controlled on Basal Insulin and Oral Antihyperglycemic Medications.

    PubMed

    Ma, Xiaosu; Chien, Jenny Y; Johnson, Jennal; Malone, James; Sinha, Vikram

    2017-08-01

    The purpose of this prospective, model-based simulation approach was to evaluate the impact of various rapid-acting mealtime insulin dose-titration algorithms on glycemic control (hemoglobin A1c [HbA1c]). Seven stepwise, glucose-driven insulin dose-titration algorithms were evaluated with a model-based simulation approach by using insulin lispro. Pre-meal blood glucose readings were used to adjust insulin lispro doses. Two control dosing algorithms were included for comparison: no insulin lispro (basal insulin+metformin only) or insulin lispro with fixed doses without titration. Of the seven dosing algorithms assessed, daily adjustment of insulin lispro dose, when glucose targets were met at pre-breakfast, pre-lunch, and pre-dinner, sequentially, demonstrated greater HbA1c reduction at 24 weeks, compared with the other dosing algorithms. Hypoglycemic rates were comparable among the dosing algorithms except for higher rates with the insulin lispro fixed-dose scenario (no titration), as expected. The inferior HbA1c response for the "basal plus metformin only" arm supports the additional glycemic benefit with prandial insulin lispro. Our model-based simulations support a simplified dosing algorithm that does not include carbohydrate counting, but that includes glucose targets for daily dose adjustment to maintain glycemic control with a low risk of hypoglycemia.

  2. Sensitivity of the acid-base properties of clays to the methods of preparation and measurement. 2. Evidence from continuous potentiometric titrations.

    PubMed

    Duc, Myriam; Gaboriaud, Fabien; Thomas, Fabien

    2005-09-01

    The effects of experimental procedures on the acid-base consumption titration curves of montmorillonite suspension were studied using continuous potentiometric titration. For that purpose, the hysteresis amplitudes between the acid and base branches were found to be useful to systematically evaluate the impacts of storage conditions (wet or dried), the atmosphere in titration reactor, the solid-liquid ratio, the time interval between successive increments, and the ionic strength. In the case of storage conditions, the increase of the hysteresis was significantly higher for longer storage of clay in suspension and drying procedures compared to "fresh" clay suspension. The titration carried out under air demonstrated carbonate contamination that could only be cancelled by performing experiments under inert gas. Interestingly, the increase of the time intervals between successive increments of titrant strongly emphasized the amplitude of hysteresis, which could be correlated with the slow kinetic process specifically observed for acid addition in acid media. Thus, such kinetic behavior is probably associated with dissolution processes of clay particles. However, the resulting curves recorded at different ionic strengths under optimized conditions did not show the common intersection point required to define point of zero charge. Nevertheless, the ionic strength dependence of the point of zero net proton charge suggested that the point of zero charge of sodic montmorillonite could be estimated as lower than 5.

  3. Surface acid-base behaviors of Chinese loess.

    PubMed

    Chu, Zhaosheng; Liu, Wenxin; Tang, Hongxiao; Qian, Tianwei; Li, Shushen; Li, Zhentang; Wu, Guibin

    2002-08-15

    Acid-base titration was applied to investigate the surface acid-base properties of a Chinese loess sample at different ionic strengths. The acidimetric supernatant was regarded as the system blank of titration to correct the influence of particle dissolution on the estimation of proton consumption. The titration behavior of the system blank could be described by the hydrolysis of Al3+ and Si(OH)4 in aqueous solution as well as the production of hydroxyaluminosilicates. The formation of Al-Si species on homogeneous surface sites by hydrous aluminum and silicic acid, released from solid substrate during the acidic titration, was considered in the model description of the back-titration procedure. A surface reaction model was suggested as follows: >SOH<-->SO(-)+H+, pK(a)(int)=3.48-3.98;>SOH+Al(3+)+H4SiO4<-->SOAl(OSi(OH)3(+)+2H+, pK(SC)=3.48-4.04. Two simple surface complexation models accounted for the interfacial structure, i.e., the constant capacitance model (CCM) and the diffuse layer model (DLM), and gave a satisfactory description of the experimental data. Considering the effect of ionic strength on the electrostatic profile at the solid-aqueous interface, the DLM was appropriate at the low concentrations (0.01 and 0.005 mol/L) of background electrolyte (NaNO3 in this study), while the CCM was preferable in the case of high ionic strength (0.1 mol/L).

  4. Real-time PCR-based infectivity assay for the titration of turkey hemorrhagic enteritis virus, an adenovirus, in live vaccines.

    PubMed

    Mahsoub, Hassan M; Evans, Nicholas P; Beach, Nathan M; Yuan, Lijuan; Zimmerman, Kurt; Pierson, Frank W

    2017-01-01

    The current in vitro titration method for turkey hemorrhagic enteritis virus (THEV) is the end-point dilution assay (EPD) in suspension cell culture (CC). This assay is subjective and results in high variability among vaccine lots. In this study, a new in vitro infectivity method combining a SYBR Green I-based qPCR assay and CC was developed for titration of live hemorrhagic enteritis (HE) CC vaccines. The qPCR was used to determine the virus genome copy number (vGCN) of the internalized virus particles following inoculation of susceptible RP19 cells with 1 vaccine label dose. The measured vGCN represents the number of infectious viral particles (IVP) per 1 dose. This method was used to compare 9 vaccine lots from 3 companies in the United States. Significant lot-to-lot variations within the same company and among the various companies were found in genomic and qPCR-based infectious titer per label dose. A positive linear relationship was found between qPCR infectious titer and genomic titer. Further, considerable variations in CCID 50 titers were found among tested vaccine lots, indicating the high variability of the current titration methods. The new method provides an alternative to classical titration assays and can help reduce variation among HE vaccine products. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. A short 2 week dose titration regimen reduces the severity of flu-like symptoms with initial interferon gamma-1b treatment.

    PubMed

    Devane, John G; Martin, Mary L; Matson, Mark A

    2014-06-01

    Flu-like symptoms (FLS) are commonly experienced by patients receiving interferon gamma-1b which may cause discontinuation or disruption of dosing during initial therapy or on re-initiation following a break in therapy. In contrast to Type I interferons, the impact of dose-titration on FLS has not been reported and is not a practice described or included in the approved prescribing information for interferon gamma-1b.The objective of this study was to assess the effect of a 2 week titration regimen on the severity of FLS during the initial 3 weeks of therapy with three times weekly subcutaneous injections of interferon gamma-1b. Healthy men and women were randomized into a double-blind, two-period, crossover study. Each study period was 3 weeks in duration and there was a minimum 15 day washout between treatment periods. Two treatment regimens were compared: No Titration dosing (full 50 mcg/m(2) subcutaneously [s.c.] three times weekly for 3 weeks) and Titration (15 mcg/m(2) s.c. three times weekly during week 1, 30 mcg/m(2) s.c. three times weekly during week 2 followed by the full dose of 50 mcg/m(2) s.c. three times weekly during week 3). Subjects remained in the clinic for at least 12 hours following each injection. FLS was based on a composite score for fever, chills, tiredness and muscle aches assessed at baseline and 4, 8 and 12 hours following each injection. Acetaminophen was allowed at the discretion of the PI. The primary endpoint was the change from baseline in FLS severity at 8 hours averaged over the 3 weeks of treatment. Additional endpoints included FLS at 4 and 12 hours, individual flu-like symptoms, rates of discontinuation, incidence of FLS and acetaminophen use. NCT 01929382. Of the 40 subjects randomized, there were 15 (37.5%) discontinuations. Titration resulted in a significant reduction in FLS severity at 8 hours (p = 0.023) averaged over the 3 week treatment period. The difference in 3 week FLS severity reflects differences during week 1 treatment, indicating an early peak in FLS severity during the No Titration treatment and subsequent development of tolerance. In contrast, titration results in near baseline severity scores throughout the treatment period. Similar trends were seen for 4 and 12 hour FLS severity scores. Of the individual FLS, difference in fever severity was most marked. Safety profiles for both regimens were consistent with the approved prescribing information for interferon gamma-1b. Study limitations included the use of healthy subjects rather than disease subjects, the lack of a validated assessment tool for evaluating FLS and the relatively high discontinuation rate. A short 2 week, dose-titration regimen reduces FLS severity following interferon gamma-1b treatment initiation in normal subjects.

  6. Virtual Titrator: A Student-Oriented Instrument.

    ERIC Educational Resources Information Center

    Ritter, David; Johnson, Michael

    1997-01-01

    Describes a titrator system, constructed from a computer-interfaced pH-meter, that was designed to increase student involvement in the process. Combines automatic data collection with real-time graphical display and interactive controls to focus attention on the process rather than on bits of data. Improves understanding of concepts and…

  7. Acid Rain Analysis by Standard Addition Titration.

    ERIC Educational Resources Information Center

    Ophardt, Charles E.

    1985-01-01

    The standard addition titration is a precise and rapid method for the determination of the acidity in rain or snow samples. The method requires use of a standard buret, a pH meter, and Gran's plot to determine the equivalence point. Experimental procedures used and typical results obtained are presented. (JN)

  8. Determination of Acidity Constants by Gradient Flow-Injection Titration

    ERIC Educational Resources Information Center

    Conceicao, Antonio C. L.; Minas da Piedade, Manuel E.

    2006-01-01

    A three-hour laboratory experiment, designed for an advanced undergraduate course in instrumental analysis that illustrates the application of the gradient chamber flow-injection titration (GCFIT) method with spectrophotometric detection to determine acidity constants is presented. The procedure involves the use of an acid-base indicator to obtain…

  9. Evaluation of the number of ionogenic groups of inulinase by acid-base titration.

    PubMed

    Kovaleva, T A; Holyavka, M G; Rezvan, S G; Kozhedub, S V

    2008-06-01

    Acid base titration showed that Aspergillus awamori inulinase includes 178 asparaginic and glutamic acid residues, 20 histidine, 10 serine, and 34 lysine and tyrosine residues. Denaturation temperature for this enzyme was calculated using analysis of the proportion of stabilizing and destabilizing amino acids in the molecule.

  10. Coulometric Titration of Ethylenediaminetetraacetate (EDTA) with Spectrophotometric Endpoint Detection: An Experiment for the Instrumental Analysis Laboratory

    ERIC Educational Resources Information Center

    Williams, Kathryn R.; Young, Vaneica Y.; Killian, Benjamin J.

    2011-01-01

    Ethylenediaminetetraacetate (EDTA) is commonly used as an anticoagulant in blood-collection procedures. In this experiment for the instrumental analysis laboratory, students determine the quantity of EDTA in commercial collection tubes by coulometric titration with electrolytically generated Cu[superscript 2+]. The endpoint is detected…

  11. The Use and Evaluation of Videodiscs in the Chemistry Laboratory.

    ERIC Educational Resources Information Center

    Russell, Arlene A.; And Others

    1985-01-01

    Describes a quantitative evaluation of an interactive videodisc program in which students measure the temperature dependence of the solubility product of lead chloride by titration of chloride with silver nitrate using a Mohr titration. Student reaction (based on responses made using the program, quiz answers, and laboratory performance) was…

  12. Titration Calculations with Computer Algebra Software

    ERIC Educational Resources Information Center

    Lachance, Russ; Biaglow, Andrew

    2012-01-01

    This article examines the symbolic algebraic solution of the titration equations for a diprotic acid, as obtained using "Mathematica," "Maple," and "Mathcad." The equilibrium and conservation equations are solved symbolically by the programs to eliminate the approximations that normally would be performed by the student. Of the three programs,…

  13. The Simulation of an Oxidation-Reduction Titration Curve with Computer Algebra

    ERIC Educational Resources Information Center

    Whiteley, Richard V., Jr.

    2015-01-01

    Although the simulation of an oxidation/reduction titration curve is an important exercise in an undergraduate course in quantitative analysis, that exercise is frequently simplified to accommodate computational limitations. With the use of readily available computer algebra systems, however, such curves for complicated systems can be generated…

  14. What is the evidence behind the evidence-base? The premature death of block-replace antithyroid drug regimens for Graves' disease.

    PubMed

    Razvi, Salman; Vaidya, Bijay; Perros, Petros; Pearce, Simon H S

    2006-06-01

    Block-replace and titration antithyroid drug regimens both give similar rates of medium- to long-term remission of hyperthyroid Graves' disease. Recent meta-analysis, however, has suggested that titration regimens may be preferable owing to a higher rate of adverse events seen in the block-replace arms of published comparative studies. This article critically re-evaluates the evidence upon which these meta-analyses were based. We suggest that there is little objective evidence that is pertinent to current clinical practice to separate block-replace from titration antithyroid drug regimens and that both remain satisfactory approaches to the medical management of hyperthyroid Graves' disease.

  15. Pilot Study on the Safety and Tolerability of Extended Release Niacin for HIV-infected Patients with Hypertriglyceridemia

    PubMed Central

    Souza, Scott A; Walsh, Erica J; Shippey, Ford; Shikuma, Cecilia

    2010-01-01

    Background To determine the safety and tolerability of extended release niacin (ERN) in HIV-infected patients. Methods This was a pilot, open-label, 36 week study evaluating the safety and tolerability of ERN in HIV-infected patients with hypertriglyceridemia. Subjects with cardiovascular disease, diabetes or liver disease were excluded. Subjects with persistent elevation of triglyceride (TG) >200 after 8 weeks on American Heart Association Step One and Two Diets were started on ERN 500mg once daily, with continuation of the diet and exercise recommendations until the end of the study. ERN was increased by 500mg every 4 weeks, to a maximum of 1500mg/day, depending on subject tolerability. Safety and tolerability of ERN were assessed. Results Ten subjects enrolled received ERN. Dose titration and maintenance to 1500mg/day were achieved in all 10 subjects. No subject required dose adjustment. Mild flushing was experienced in 8 subjects. Asymptomatic hypophosphotemia was noted in 4 subjects; all resolved with oral phosphate supplementation. Median TG was reduced by 254 mg/dL (p<0.05). Non-significant changes were noted in liver enzymes, HDL, LDL, and total cholesterol. Fasting insulin and glucose levels did not change with treatment. Conclusion In this pilot study, ERN was well-tolerated and resulted in reduction of TG. Although the results of this study are promising, the study is limited in the small number of subjects. Further investigation is warranted. PMID:20533755

  16. Developing and Demonstrating an Augmented Reality Colorimetric Titration Tool

    ERIC Educational Resources Information Center

    Tee, Nicholas Yee Kwang; Gan, Hong Seng; Li, Jonathan; Cheong, Brandon Huey-Ping; Tan, Han Yen; Liew, Oi Wah; Ng, Tuck Wah

    2018-01-01

    The handling of chemicals in the laboratory presents a challenge in instructing large class sizes and when students are relatively new to the laboratory environment. In this work, we describe and demonstrate an augmented reality colorimetric titration tool that operates out of the smartphone or tablet of students. It allows multiple students to…

  17. Thermometric titration of beta-aryl-alpha-mercaptopropenoic acids and determination of the stoichiometry of their metal complexes.

    PubMed

    Izquierdo, A; Carrasco, J

    1981-05-01

    Automatic thermometric titration was applied to some beta-aryl-alpha-mercaptopropenoic acids and the stoichiometry of their complexes with several metal ions was investigated. The heats of neutralization of the mercapto-acids with sodium hydroxide and the heats of their reaction with metal ions were calculated.

  18. Isothermal Titration Calorimetry in the Student Laboratory

    ERIC Educational Resources Information Center

    Wadso, Lars; Li, Yujing; Li, Xi

    2011-01-01

    Isothermal titration calorimetry (ITC) is the measurement of the heat produced by the stepwise addition of one substance to another. It is a common experimental technique, for example, in pharmaceutical science, to measure equilibrium constants and reaction enthalpies. We describe a stirring device and an injection pump that can be used with a…

  19. Titration and HPLC Characterization of Kombucha Fermentation: A Laboratory Experiment in Food Analysis

    ERIC Educational Resources Information Center

    Miranda, Breanna; Lawton, Nicole M.; Tachibana, Sean R.; Swartz, Natasja A.; Hall, W. Paige

    2016-01-01

    Quantification of the many constituents that make up our food, whether they are desirable (vitamins, antioxidants, nutrients) or undesirable (pesticides, toxins), is one of the most practical applications of chemistry. In this study, kombucha, a popular fermented tea beverage, was analyzed using acid-base titration and high-performance liquid…

  20. 27 CFR 21.102 - Caustic soda, liquid.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... mark with distilled water at room temperature. Transfer a 25 ml aliquot of the solution to a titration..., and 50 ml of distilled water. Titrate with 0.25 N hydrochloric acid to the disappearance of the pink color. Not less than 25 ml of the hydrochloric acid shall be required to neutralize the sample of...

  1. 27 CFR 21.102 - Caustic soda, liquid.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... mark with distilled water at room temperature. Transfer a 25 ml aliquot of the solution to a titration..., and 50 ml of distilled water. Titrate with 0.25 N hydrochloric acid to the disappearance of the pink color. Not less than 25 ml of the hydrochloric acid shall be required to neutralize the sample of...

  2. 27 CFR 21.102 - Caustic soda, liquid.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... mark with distilled water at room temperature. Transfer a 25 ml aliquot of the solution to a titration..., and 50 ml of distilled water. Titrate with 0.25 N hydrochloric acid to the disappearance of the pink color. Not less than 25 ml of the hydrochloric acid shall be required to neutralize the sample of...

  3. 27 CFR 21.102 - Caustic soda, liquid.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... mark with distilled water at room temperature. Transfer a 25 ml aliquot of the solution to a titration..., and 50 ml of distilled water. Titrate with 0.25 N hydrochloric acid to the disappearance of the pink color. Not less than 25 ml of the hydrochloric acid shall be required to neutralize the sample of...

  4. 27 CFR 21.102 - Caustic soda, liquid.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... mark with distilled water at room temperature. Transfer a 25 ml aliquot of the solution to a titration..., and 50 ml of distilled water. Titrate with 0.25 N hydrochloric acid to the disappearance of the pink color. Not less than 25 ml of the hydrochloric acid shall be required to neutralize the sample of...

  5. Microcalorimetric and potentiometric titration studies on the adsorption of copper by extracellular polymeric substances (EPS), minerals and their composites.

    PubMed

    Fang, Linchuan; Huang, Qiaoyun; Wei, Xing; Liang, Wei; Rong, Xinming; Chen, Wenli; Cai, Peng

    2010-08-01

    Equilibrium adsorption experiments, isothermal titration calorimetry and potentiometric titration techniques were employed to investigate the adsorption of Cu(II) by extracellular polymeric substances (EPS) extracted from Pseudomonas putida X4, minerals (montmorillonite and goethite) and their composites. Compared with predicted values of Cu(II) adsorption on composites, the measured values of Cu(II) on EPS-montmorillonite composite increased, however, those on EPS-goethite composite decreased. Potentiometric titration results also showed that more surface sites were observed on EPS-montmorillonite composite and less reactive sites were found on EPS-goethite composite. The adsorption of Cu(II) on EPS molecules and their composites with minerals was an endothermic reaction, while that on minerals was exothermic. The positive values of enthalpy change (Delta H) and entropy change (DeltaS) for Cu(II) adsorption on EPS and mineral-EPS composites indicated that Cu(II) mainly interacts with carboxyl and phosphoryl groups as inner-sphere complexes on EPS molecules and their composites with minerals. (c) 2010 Elsevier Ltd. All rights reserved.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zarzycki, Piotr P.; Rosso, Kevin M.

    Replica Kinetic Monte Carlo simulations were used to study the characteristic time scales of potentiometric titration of the metal oxides and (oxy)hydroxides. The effect of surface heterogeneity and surface transformation on the titration kinetics were also examined. Two characteristic relaxation times are often observed experimentally, with the trailing slower part attributed to surface non-uniformity, porosity, polymerization, amorphization, and other dynamic surface processes induced by unbalanced surface charge. However, our simulations show that these two characteristic relaxation times are intrinsic to the proton binding reaction for energetically homogeneous surfaces, and therefore surface heterogeneity or transformation do not necessarily need to bemore » invoked. However, all such second-order surface processes are found to intensify the separation and distinction of the two kinetic regimes. The effect of surface energetic-topographic non-uniformity, as well dynamic surface transformation, interface roughening/smoothing were described in a statistical fashion. Furthermore, our simulations show that a shift in the point-of-zero charge is expected from increased titration speed and the pH-dependence of the titration measurement error is in excellent agreement with experimental studies.« less

  7. Efficacy and Safety of Lacosamide in Painful Diabetic Neuropathy

    PubMed Central

    Ziegler, Dan; Hidvégi, Tibor; Gurieva, Irina; Bongardt, Sabine; Freynhagen, Rainer; Sen, David; Sommerville, Kenneth

    2010-01-01

    OBJECTIVE To evaluate efficacy and safety of lacosamide compared with placebo in painful diabetic polyneuropathy. RESEARCH DESIGN AND METHODS Diabetic patients with at least moderate neuropathic pain were randomized to placebo or lacosamide 400 (in a slow or standard titration) or 600 mg/day over 6-week titration and 12-week maintenance periods. Primary efficacy criterion was intra-individual change in average daily Numeric Pain Rating Scale score from baseline to the last 4 weeks. RESULTS For the primary end point, pain reduction was numerically but not statistically greater with lacosamide compared with placebo (400 mg/day, P = 0.12; 600 mg/day, P = 0.18). Both doses were significantly more effective compared with placebo over the titration (P = 0.03, P = 0.006), maintenance (P = 0.01, P = 0.005), and entire treatment periods (P = 0.03, P = 0.02). Safety profiles between titration schemes were similar. CONCLUSIONS Lacosamide reduced neuropathic pain and was well tolerated in diabetic patients, but the primary efficacy criterion was not met, possibly due to an increased placebo response over the last 4 weeks. PMID:20067958

  8. Comparison between amperometric and true potentiometric end-point detection in the determination of water by the Karl Fischer method.

    PubMed

    Cedergren, A

    1974-06-01

    A rapid and sensitive method using true potentiometric end-point detection has been developed and compared with the conventional amperometric method for Karl Fischer determination of water. The effect of the sulphur dioxide concentration on the shape of the titration curve is shown. By using kinetic data it was possible to calculate the course of titrations and make comparisons with those found experimentally. The results prove that the main reaction is the slow step, both in the amperometric and the potentiometric method. Results obtained in the standardization of the Karl Fischer reagent showed that the potentiometric method, including titration to a preselected potential, gave a standard deviation of 0.001(1) mg of water per ml, the amperometric method using extrapolation 0.002(4) mg of water per ml and the amperometric titration to a pre-selected diffusion current 0.004(7) mg of water per ml. Theories and results dealing with dilution effects are presented. The time of analysis was 1-1.5 min for the potentiometric and 4-5 min for the amperometric method using extrapolation.

  9. Thermodynamic analysis of Bacillus subtilis endospore protonation using isothermal titration calorimetry

    NASA Astrophysics Data System (ADS)

    Harrold, Zoë R.; Gorman-Lewis, Drew

    2013-05-01

    Bacterial proton and metal adsorption reactions have the capacity to affect metal speciation and transport in aqueous environments. We coupled potentiometric titration and isothermal titration calorimetry (ITC) analyses to study Bacillus subtilis spore-proton adsorption. We modeled the potentiometric data using a four and five-site non-electrostatic surface complexation model (NE-SCM). Heats of spore surface protonation from coupled ITC analyses were used to determine site specific enthalpies of protonation based on NE-SCMs. The five-site model resulted in a substantially better model fit for the heats of protonation but did not significantly improve the potentiometric titration model fit. The improvement observed in the five-site protonation heat model suggests the presence of a highly exothermic protonation reaction circa pH 7 that cannot be resolved in the less sensitive potentiometric data. From the log Ks and enthalpies we calculated corresponding site specific entropies. Log Ks and site concentrations describing spore surface protonation are statistically equivalent to B. subtilis cell surface protonation constants. Spore surface protonation enthalpies, however, are more exothermic relative to cell based adsorption suggesting a different bonding environment. The thermodynamic parameters defined in this study provide insight on molecular scale spore-surface protonation reactions. Coupled ITC and potentiometric titrations can reveal highly exothermic, and possibly endothermic, adsorption reactions that are overshadowed in potentiometric models alone. Spore-proton adsorption NE-SCMs derived in this study provide a framework for future metal adsorption studies.

  10. Effect of dissolved oxygen on two bacterial pathogens examined using ATR-FTIR spectroscopy, microelectrophoresis, and potentiometric titration.

    PubMed

    Castro, Felipe D; Sedman, Jacqueline; Ismail, Ashraf A; Asadishad, Bahareh; Tufenkji, Nathalie

    2010-06-01

    The effects of dissolved oxygen tension during bacterial growth and acclimation on the cell surface properties and biochemical composition of the bacterial pathogens Escherichia coli O157:H7 and Yersinia enterocolitica are characterized. Three experimental techniques are used in an effort to understand the influence of bacterial growth and acclimation conditions on cell surface charge and the composition of the bacterial cell: (i) electrophoretic mobility measurements; (ii) potentiometric titration; and (iii) ATR-FTIR spectroscopy. Potentiometric titration data analyzed using chemical speciation software are related to measured electrophoretic mobilities at the pH of interest. Titration of bacterial cells is used to identify the major proton-active functional groups and the overall concentration of these cell surface ligands at the cell membrane. Analysis of titration data shows notable differences between strains and conditions, confirming the appropriateness of this tool for an overall charge characterization. ATR-FTIR spectroscopy of whole cells is used to further characterize the bacterial biochemical composition and macromolecular structures that might be involved in the development of the net surficial charge of the organisms examined. The evaluation of the integrated intensities of HPO(2)(-) and carbohydrate absorption bands in the IR spectra reveals clear differences between growth protocols. Taken together, the three techniques seem to indicate that the dissolved oxygen tension during cell growth or acclimation can noticeably influence the expression of cell surface molecules and the measurable cell surface charge, though in a strain-dependent fashion.

  11. Comparative evaluation of gel column agglutination and erythrocyte magnetized technology for red blood cell alloantibody titration.

    PubMed

    Dubey, Anju; Sonker, Atul; Chaudhary, Rajendra K

    2015-01-01

    Antibody titration is traditionally performed using a conventional test tube (CTT) method, which is subjected to interlaboratory variations because of a lack of standardization and reproducibility. The aim of this study is to compare newer methods such as get column technology (GCT) and erythrocyte magnetized technology (EMT) for antibody titration in terms of accuracy and precision. Patient serum samples that contained immunoglobin G (IgG) red blood cell (RBC) alloantibodies of a single specificity for Rh or K anitgens were identified during routine transfusion service testing and stored. Titration and scoring were performed separately by and stored. Titration and scoring were performed separately by different laboratory personnel on CTT, GCT, and EMT. Testing was performed a total of three times on each sample. Results were analyzed for accuracy and precision. A total of 50 samples were tested. Only 20 percent of samples tested with GCT shoed titers identical to CTT, whereas 48 percent of samples tested with EMT showed titers identical to CTT. Overall, the mean of th titer difference from CTT was higher using GCT (+0.31) compared with that using EMT (+0.13). Precision shown by CTT was 30 percent, EMT was 76 percent, and GCT was 92 percent on repeat testing. GCT showed higher titer values in comparison with CTT but was found to be the most precise. EMT titers were comparable to CTT, and its precision was intermediate. Further studies to validate this method are required.

  12. Asphalt compatibility testing using the automated Heithaus titration test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pauli, A.T.

    1996-12-31

    The Heithaus titration test or variations of the test have been used for over 35 years to predict compatibilities of blends of asphalts from different crude sources. Asphalt compatibility is determined from three calculated parameters that measure the state of peptization of an asphalt or asphalt blend. The parameter p{sub a} is a measure of the peptizability of the asphaltenes. The parameter p{sub a} is a measure of the peptizing power of the maltenes, and the parameter P, derived from p{sub a} and p{sub o} values, is a measure of the overall state of peptization of the asphalt or asphaltmore » blend. In Heithaus original procedure, samples of asphalt were dissolved in toluene and titrated with n-heptane in order to initiate flocculation. The onset of flocculation was detected either by photography or by spotting a filter paper with a small amount of the titrated solution. Recently, an {open_quotes}automated{close_quotes} procedure, after Hotier and Robin, has been developed for use with asphalt. In the automated method UV-visible spectrophotometric detection measures the onset of flocculation as a peak with the percent transmittance plotted as a function of the volume of titrating solvent added to a solution of asphalt. The automated procedure has proven to be less operator dependent and much faster than the original Heithaus procedure. Results from the automated procedure show the data to be consistent with results from the original, {open_quotes}classical{close_quotes} Heithaus procedure.« less

  13. [Three-dimensional finite element study on the change of glossopharyngeum in patient with obstructive sleep apnea hypopnea syndrome during titrated mandible advancement].

    PubMed

    Yang, Suixing; Feng, Jing; Zhang, Zuo; Qu, Aili; Gong, Miao; Tang, Jie; Fan, Junheng; Li, Songqing; Zhao, Yanling

    2013-04-01

    To construct a three-dimensional finite element model of the upper airway and adjacent structure of an obstructive sleep apnea hypopnea syndrome (OSAHS) patient for biomechanical analysis. And to study the influence of glossopharyngeum of an OSAHS patient with three-dimensional finite element model during titrated mandible advancement. DICOM format image information of an OSAHS patient's upper airway was obtained by thin-section CT scanning and digital image processing were utilized to construct a three-dimensional finite element model by Mimics 10.0, Imageware 10.0 and Ansys software. The changes and the law of glossopharyngeum were observed by biomechanics and morphology after loading with titrated mandible advancement. A three-dimensional finite element model of the adjacent upper airway structure of OSAHS was established successfully. After loading, the transverse diameter of epiglottis tip of glossopharyngeum increased significantly, although the sagittal diameter decreased correspondingly. The principal stress was mainly distributed in anterior wall of the upper airway. The location of principal stress concentration did not change significantly with the increasing of distance. The stress of glossopharyngeum increased during titrated mandible advancement. A more precise three-dimensional finite model of upper airway and adjacent structure of an OSAHS patient is established and improved efficiency by Mimics, Imageware and Ansys software. The glossopharyngeum of finite element model of OSAHS is analyzed by titrated mandible advancement and can effectively show the relationship between mandible advancement and the glossopharyngeum.

  14. Preliminary findings on the correlation of saliva pH, buffering capacity, flow rate and consistency in relation to waterpipe tobacco smoking

    PubMed Central

    Khemiss, Mehdi; Ben Khelifa, Mohamed; Ben Saad, Helmi

    2017-01-01

    ABSTRACT The aim of the present comparative study was to compare some salivary characteristics between exclusive waterpipe smokers (EWPS) and non-smokers. 72 males (36 EWPS) were recruited. The volume of stimulated saliva was determined and divided by the duration of saliva collection. The pH was measured directly using a pH meter. The buffering capacity was determined using a quantitative method which involved the addition of 10 µl HCl. Up to a total of 160 µL was titrated up to obtain a pH titration curve. At 50 µL of titrated HCl, buffering capacity was ranked into three categories: high, medium and low. EWPS and non-smoker groups had similar flow rates (1.81 ± 0.79 and 1.78 ± 1.14 mL min-1) and similar baseline pH (6.60 ± 0.37 and 6.76 ± 0.39). Statistically significant differences in the two groups’ pH were observed from 30 to 160 µL of titrated up HCl. At 50 µL of titrated up HCl, the EWPS group compared to the non-smoker group had a significantly higher pH (4.79 ± 0.72 vs. 5.32 ± 0.79). To conclude, waterpipe tobacco smoking alters the buffering capacity but does not alter either salivary flow rates or the baseline pH and consistency. PMID:28266252

  15. Assessment of Knowledge of Self Blood Glucose Monitoring and Extent of Self Titration of Anti-Diabetic Drugs among Diabetes Mellitus Patients - A Cross Sectional, Community Based Study.

    PubMed

    Krishnan, V; Thirunavukkarasu, J

    2016-03-01

    Self blood glucose monitoring is an important context of self care in the management of diabetes mellitus. All the guidelines must be followed while performing self blood glucose monitoring and tracking of values is essential to facilitate the physician while titrating the drugs and /or doses of anti diabetes medication. Self titration by patients following self monitoring must be discouraged. To assess the knowledge and practice of self blood glucose monitoring among diabetes patients and extent of self titration of anti diabetes medicines among diabetes patients based on self blood glucose monitoring. This pilot, cross-sectional, observational study was conducted using a validated questionnaire among adult male and female diabetes patients performing self blood glucose monitoring at home. Diabetes patients with complications and juvenile diabetes patients were excluded. Out of 153 patients surveyed, only 37 (24.1%) (20 males, 17 females) patients were aware and have been following self blood glucose monitoring appropriately. About 116 (75.8%) (64 males, 52 females) of patients were devoid of adequate knowledge and did not practice self blood glucose monitoring in a proper way. Ninety eight (64.05%) accepted that they self titrate their anti diabetic medicines based on self monitoring. Self monitoring of blood glucose should be encouraged and patients should be taught importance of following correct steps and tracking of self monitoring by physician or diabetes educator.

  16. Thermodynamic investigations of protein's behaviour with ionic liquids in aqueous medium studied by isothermal titration calorimetry.

    PubMed

    Bharmoria, Pankaj; Kumar, Arvind

    2016-05-01

    While a number of reports appear on ionic liquids-proteins interactions, their thermodynamic behaviour using suitable technique like isothermal titration calorimetry is not systematically presented. Isothermal titration calorimetry (ITC) is a key technique which can directly measure the thermodynamic contribution of IL binding to protein, particularly the enthalpy, heat capacities and binding stoichiometry. Ionic liquids (ILs), owing to their unique and tunable physicochemical properties have been the central area of scientific research besides graphene in the last decade, and growing unabated. Their encounter with proteins in the biological system is inevitable considering their environmental discharge though most of them are recyclable for a number of cycles. In this article we will cover the thermodynamics of proteins upon interaction with ILs as osmolyte and surfactant. The up to date literature survey of IL-protein interactions using isothermal titration calorimetry will be discussed and parallel comparison with the results obtained for such studies with other techniques will be highlighted to demonstrate the accuracy of ITC technique. Net stability of proteins can be obtained from the difference in the free energy (ΔG) of the native (folded) and denatured (unfolded) state using the Gibbs-Helmholtz equation (ΔG=ΔH-TΔS). Isothermal titration calorimetry can directly measure the heat changes upon IL-protein interactions. Calculation of other thermodynamic parameters such as entropy, binding constant and free energy depends upon the proper fitting of the binding isotherms using various fitting models. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Acidic beverages increase the risk of in vitro tooth erosion.

    PubMed

    Ehlen, Leslie A; Marshall, Teresa A; Qian, Fang; Wefel, James S; Warren, John J

    2008-05-01

    Acidic beverages are thought to increase the potential for dental erosion. We report pH and titratable acidities (ie, quantity of base required to bring a solution to neutral pH) of beverages popular in the United States and lesion depths in enamel and root surfaces after beverage exposure, and we describe associations among pH, titratable acidity, and both enamel and root erosive lesion depths. The pH of 100% juices, regular sodas, diet sodas, and sports drinks upon opening and the titratable acidity both upon opening and after 60 minutes of stirring were measured. Enamel and root surfaces of healthy permanent molars and premolars were exposed to individual beverages (4 enamel and 4 root surfaces per beverage) for 25 hours, and erosion was measured. Statistical analyses included 2-sample t tests, analyses of variance with post hoc Tukey studentized range test; and Spearman rank correlation coefficients. All beverages were acidic; the titratable acidity of energy drinks was greater than that of regular and diet sodas that were greater than that of 100% juices and sports drinks (P < .05). Enamel lesion depths after beverage exposures were greatest for Gatorade, followed by those for Red Bull and Coke that were greater than those for Diet Coke and 100% apple juice (P < .05). Root lesion depths were greatest for Gatorade, followed by Red Bull, Coke, 100% apple juice, and Diet Coke (P < .05). Lesion depths were not associated with pH or titratable acidity. Beverages popular in the United States can produce dental erosion.

  18. Depression May Reduce Adherence during CPAP Titration Trial

    PubMed Central

    Law, Mandy; Naughton, Matthew; Ho, Sally; Roebuck, Teanau; Dabscheck, Eli

    2014-01-01

    Study Objectives: Depression is a risk factor for medication non-compliance. We aimed to identify if depression is associated with poorer adherence during home-based autotitrating continuous positive airway pressure (autoPAP) titration. Design: Mixed retrospective-observational study. Setting: Academic center. Participants: Two-hundred forty continuous positive airway pressure-naïve obstructive sleep apnea (OSA) patients. Measurements: Patients underwent approximately 1 week of home-based autoPAP titration with adherence data downloaded from the device. Electronic hospital records were reviewed in a consecutive manner for inclusion. Three areas of potential predictors were examined: (i) demographics and clinical factors, (ii) disease severity, and (iii) device-related variables. Depression and anxiety were assessed using the Hospital Anxiety and Depression Scale (HADS). Scores on the subscales were categorized as normal or clinical diagnoses of depression (≥ 8) and anxiety (≥ 11). The primary outcome variable was the mean hours of autoPAP used per night. Results: Patients were diagnosed with OSA by either attended polysomnography (n = 73, AHI 25.5[15.1-41.5]) or unattended home oximetry (n = 167, ODI3 34.0[22.4-57.4]) and had home-based autoPAP titration over 6.2 ± 1.2 nights. Mean autoPAP use was 4.5 ± 2.4 hours per night. Multiple linear regression analysis revealed that depression and lower 95th percentile pressures significantly predicted lesser hours of autoPAP use (R2 = 0.19, p < 0.001). Significantly milder OSA in those requiring lower pressures may have confounded the relationship between 95th percentile pressure and autoPAP use. Conclusion: Depression was independently associated with poorer adherence during home-based autoPAP titration. Depression may be a potential target for clinicians and future research aimed at enhancing adherence to autoPAP therapy. Citation: Law M; Naughton M; Ho S; Roebuck T; Dabscheck E. Depression may reduce adherence during CPAP titration trial. J Clin Sleep Med 2014;10(2):163-169. PMID:24532999

  19. Design of a multicentre randomized controlled trial to assess the safety and efficacy of dose titration by specialized nurses in patients with heart failure. ETIFIC study protocol.

    PubMed

    Oyanguren, Juana; García-Garrido, LLuisa; Nebot Margalef, Magdalena; Lekuona, Iñaki; Comin-Colet, Josep; Manito, Nicolás; Roure, Julia; Ruiz Rodriguez, Pilar; Enjuanes, Cristina; Latorre, Pedro; Torcal Laguna, Jesús; García-Gutiérrez, Susana

    2017-11-01

    Heart failure (HF) is associated with many hospital admissions and relatively high mortality, rates decreasing with administration of beta-blockers (BBs), angiotensin-converting-enzyme inhibitors, angiotensin II receptor blockers, and mineralocorticoid receptor antagonists. The effect is dose dependent, suboptimal doses being common in clinical practice. The 2012 European guidelines recommend close monitoring and dose titration by HF nurses. Our main aim is to compare BB doses achieved by patients after 4 months in intervention (HF nurse-managed) and control (cardiologist-managed) groups. Secondary aims include comparing doses of the other aforementioned drugs achieved after 4 months, adverse events, and outcomes at 6 months in the two groups. We have designed a multicentre (20 hospitals) non-inferiority randomized controlled trial, including patients with new-onset HF, left ventricular ejection fraction ≤40%, and New York Heart Association class II-III, with no contraindications to BBs. We will also conduct qualitative analysis to explore potential barriers to and facilitators of dose titration by HF nurses. In the intervention group, HF nurses will implement titration as prescribed by cardiologists, following a protocol. In controls, cardiologists will both prescribe and titrate doses. The study variables are doses of each of the drugs after 4 months relative to the target dose (%), New York Heart Association class, left ventricular ejection fraction, N-terminal pro B-type natriuretic peptide levels, 6 min walk distance, comorbidities, renal function, readmissions, mortality, quality of life, and psychosocial characteristics. The trial seeks to assess whether titration by HF nurses of drugs recommended in practice guidelines is safe and not inferior to direct management by cardiologists. The results could have an impact on clinical practice. © 2017 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology.

  20. Efficacy and safety of down-titration versus continuation strategies of biological disease-modifying anti-rheumatic drugs in patients with rheumatoid arthritis with low disease activity or in remission: a systematic review and meta-analysis.

    PubMed

    Jiang, Mei; Ren, Feifeng; Zheng, Yaning; Yan, Ruyu; Huang, Wenhan; Xia, Ning; Luo, Lei; Zhou, Jun; Tang, Lin

    2017-01-01

    To evaluate the efficacy and safety of down-titration (dose reduction/tapering) strategies compared with continuation of biological disease-modifying anti-rheumatic drugs (DMARDs) in patients with rheumatoid arthritis (RA) who achieved and maintained low disease activity or remission. We searched the following electronic database up to March 2016: MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials (CENTRAL), and conference proceedings of the American College of Rheumatology (ACR) and European League against Rheumatism (EULAR). Our meta-analysis included randomized controlled trials (RCTs) of RA patients with low disease activity or in remission that compared down-titration treatment with continuation treatment. Data on flare, defined as a 28-joint Disease Activity Score of ≥3.2, had to have been reported. Outcomes on efficacy or safety were collected. Of 1136 references identified, five RCTs (total, 771 participants) were included. The incidence of disease relapse in the down-titration and continuation groups was similar (risk ratio (RR)=1.14, 95% CI=0.88-1.49). There was no statistical difference in the number of serious adverse events (RR=1.15, 95% CI=0.53-2.49). Withdrawals due to inefficacy or toxicity were similar between groups and no clinically meaningful difference in efficacy outcomes was observed by continuation treatment. Our findings indicated that continuing a standard dose of biological DMARDs in patients with low disease activity conveyed no significant benefit as compared with down-titration therapy, suggesting that a down-titration strategy is as effective as a continuation strategy. Since the number of trials meeting the criteria for this meta-analysis was relatively low, future analyses with additional prospective RCTs are required to compare other biological agents and evaluate the long-term efficacy of these two strategies.

  1. ASSESSMENT OF ATTENTION THRESHOLD IN RATS BY TITRATION OF VISUAL CUE DURATION DURING THE FIVE CHOICE SERIAL REACTION TIME TASK

    PubMed Central

    Martin, Thomas J.; Grigg, Amanda; Kim, Susy A.; Ririe, Douglas G.; Eisenach, James C.

    2014-01-01

    Background The 5 choice serial reaction time task (5CSRTT) is commonly used to assess attention in rodents. We sought to develop a variant of the 5CSRTT that would speed training to objective success criteria, and to test whether this variant could determine attention capability in each subject. New Method Fisher 344 rats were trained to perform a variant of the 5CSRTT in which the duration of visual cue presentation (cue duration) was titrated between trials based upon performance. The cue duration was decreased when the subject made a correct response, or increased with incorrect responses or omissions. Additionally, test day challenges were provided consisting of lengthening the intertrial interval and inclusion of a visual distracting stimulus. Results Rats readily titrated the cue duration to less than 1 sec in 25 training sessions or less (mean ± SEM, 22.9 ± 0.7), and the median cue duration (MCD) was calculated as a measure of attention threshold. Increasing the intertrial interval increased premature responses, decreased the number of trials completed, and increased the MCD. Decreasing the intertrial interval and time allotted for consuming the food reward demonstrated that a minimum of 3.5 sec is required for rats to consume two food pellets and successfully attend to the next trial. Visual distraction in the form of a 3 Hz flashing light increased the MCD and both premature and time out responses. Comparison with existing method The titration variant of the 5CSRTT is a useful method that dynamically measures attention threshold across a wide range of subject performance, and significantly decreases the time required for training. Task challenges produce similar effects in the titration method as reported for the classical procedure. Conclusions The titration 5CSRTT method is an efficient training procedure for assessing attention and can be utilized to assess the limit in performance ability across subjects and various schedule manipulations. PMID:25528113

  2. [Dose-finding for treatment with a transdermal fentanyl patch : Titration with oral transmucosal fentanyl citrate and morphine sulfate].

    PubMed

    Mücke, M; Conrad, R; Marinova, M; Cuhls, H; Elsner, F; Rolke, R; Radbruch, L

    2016-12-01

    To date, no studies investigating titration with oral transmucosal fentanyl for the dose-finding of transdermal fentanyl treatment have been published. In an open randomized study 60 patients with chronic malignant (n = 39) or nonmalignant pain (n = 21), who required opioid therapy according to step three of the guidelines of the World Health Organization (WHO), were investigated. In two groups of 30 patients each titration with immediate release morphine (IRM) or oral transmucosal fentanyl citrate (OTFC) was undertaken. For measurement purposes the Brief Pain Inventory (BPI) and Minimal Documentation System (MIDOS) were used. After a 24-h titration phase, in which patients documented the intensity of pain, nausea, and tiredness, treatment with transdermal fentanyl was evaluated over a 10-day period by means of the necessary dose adaptation (responder ≤ 1 dose adaptation; conversion formula 1:1 [OTFC group] vs 100:1 [IRM group]).The pain reduction over the first 24 h (titration phase) did not differ significantly between the groups. The number of responders (17 OTFC vs. 21 IRM) over the 10-day period did not show any difference either. In both groups there was a significant reduction in pain intensity (p < 0.001). Over the course of the study, there were significantly more drop-outs because of adverse effects in the OTFC group than in the IRM group (8 vs 1, p = 0.028).Oral transmucosal fentanyl citrate can be applied for the titration of transdermal fentanyl, but it does not show any clinically relevant advantage. For example, the risk of side effects-induced drop-outs was greater in the present study. Whether the unnecessary opioid switching to treat chronic pain and breakthrough pain is advantageous with regard to minimizing conversion errors cannot be definitively answered within the scope of this study.

  3. Protofit: A program for determining surface protonation constants from titration data

    NASA Astrophysics Data System (ADS)

    Turner, Benjamin F.; Fein, Jeremy B.

    2006-11-01

    Determining the surface protonation behavior of natural adsorbents is essential to understand how they interact with their environments. ProtoFit is a tool for analysis of acid-base titration data and optimization of surface protonation models. The program offers a number of useful features including: (1) enables visualization of adsorbent buffering behavior; (2) uses an optimization approach independent of starting titration conditions or initial surface charge; (3) does not require an initial surface charge to be defined or to be treated as an optimizable parameter; (4) includes an error analysis intrinsically as part of the computational methods; and (5) generates simulated titration curves for comparison with observation. ProtoFit will typically be run through ProtoFit-GUI, a graphical user interface providing user-friendly control of model optimization, simulation, and data visualization. ProtoFit calculates an adsorbent proton buffering value as a function of pH from raw titration data (including pH and volume of acid or base added). The data is reduced to a form where the protons required to change the pH of the solution are subtracted out, leaving protons exchanged between solution and surface per unit mass of adsorbent as a function of pH. The buffering intensity function Qads* is calculated as the instantaneous slope of this reduced titration curve. Parameters for a surface complexation model are obtained by minimizing the sum of squares between the modeled (i.e. simulated) buffering intensity curve and the experimental data. The variance in the slope estimate, intrinsically produced as part of the Qads* calculation, can be used to weight the sum of squares calculation between the measured buffering intensity and a simulated curve. Effects of analytical error on data visualization and model optimization are discussed. Examples are provided of using ProtoFit for data visualization, model optimization, and model evaluation.

  4. Randomized cross-over trial of ventilator modes during non-invasive ventilation titration in amyotrophic lateral sclerosis.

    PubMed

    Vrijsen, Bart; Buyse, Bertien; Belge, Catharina; Vanpee, Goele; Van Damme, Philip; Testelmans, Dries

    2017-08-01

    Non-invasive ventilation (NIV) improves survival, quality of life and sleep in patients with amyotrophic lateral sclerosis (ALS). Nevertheless, NIV titration is conducted in different ways. We aim to provide more insight into NIV titration by comparing the effects of a spontaneous (S) and spontaneous-timed (ST) modes on gas exchange, sleep architecture and patient-ventilator asynchronies (PVAs). After an initial night of NIV titration, patients were randomized to S or ST mode in a cross-over design. NIV was titrated using polysomnography, oximetry (oxygen saturation, SpO 2 %) and transcutaneous carbon dioxide (PtcCO 2 ) measurement. PVAs were analysed breath-by-breath. Thirteen patients were analysed after inclusion. ST mode showed better results in gas exchange (minimal SpO 2 %: 83 (80-89)% vs 87 (84-89)%; oxygen desaturation index: 15 (5-28)/h sleep vs 7 (3-9)/h sleep; PtcCO 2 >55 mm Hg: 20 (0-59)% vs 0 (0-27)% total sleep time for S and ST mode, respectively, all P < 0.05) and respiratory events (obstructive: 8.9 (1.2-18.3)/h sleep vs 1.8 (0.3-4.9)/h sleep and central: 2.6 (0.4-14.1)/h sleep vs 0.2 (0.0-1.1)/h sleep for S and ST mode, respectively, both P < 0.01). No differences in sleep architecture were found. Ineffective efforts and respiratory events were more frequently present in S mode. Nevertheless, four patients were discharged on S mode as these patients showed clinically better results for sleep architecture and PVA during the night on S mode. ST mode shows better results in gas exchange, respiratory events and PVA. Nevertheless, accurate NIV titration remains necessary as some patients show equal or better results when using the S mode. © 2017 Asian Pacific Society of Respirology.

  5. [Photometric micro-titration model of DPPH radicals scavenging activity and its application].

    PubMed

    Gao, Yun-tao; Wei, Wei; Ye, Li-qing; Li, Xiao-fen; Liu, Ping; Zhang, Hong-jiao; Yang, Lu; Yu, Jiao-jiao; Cha, Jia-wei

    2015-02-01

    In the present paper, the stoichiometric ratio (R) for the interreaction of DPPH radicals with the antoxidant was employed as a evaluation index for DPPH radicals scavenging activity of antioxidants. This evaluation index was related only with the stoichiometric relationship between DPPH radicals and the antioxidant, not the relationship with the initial DPPH amount and the volume of sample, which could offer a solution for the problem of poor comparability of EC50 under different conditions. A novel photometric micro-titration method was proposed for the determination of the stoichiometric ratio (R) for the interreaction of DPPH radicals with the antoxidant. The titration equation was established based on the absorbance difference (deltaA) of DPPH radicals in the titration process and the added amount of antoxidant. The stoichiometric ratio (R) for the reaction of DPPH radicals with the addition amount of antoxidant was determined by the titration equation obtained, while, the DPPH median elimination concentration (EC50) of antoxidant can be calculated by the stoichiometric ratio (R). The above photometric micro-titration model was verified using rutin as DPPH radicals scavenger. As experiment results, the stoichiometric ratio (R) of DPPH radicals to rutin was determined to be in the range of 1.817-1.846. The calculated value of EC50 was 1.196 x 10(-3), 2.392 x 10(-3), 4.819 x 10(-3) and 7.292 x 10(-3) mg x mL(-1) for 1.12 x 10(-7), 2.24 x 10(-7), 4.48 x 10(-7) and 6.72 x 10(-7) mol of the additon amount of DPPH radicals, respectively. The proposed method has better precision and reliability with smaller amount of sample than conventional method. While, the obtained stoichiometric ratio value (R) of rutin was employed to calculate the rutin median elimination concentration for DPPH EC50) according to the conditions as reported in the literatures, and the calculated results were consistent with that reported in the literatures.

  6. Direct Sensing of Total Acidity by Chronopotentiometric Flash Titrations at Polymer Membrane Ion-Selective Electrodes

    PubMed Central

    Gemene, Kebede L.; Bakker, Eric

    2008-01-01

    Polymer membrane ion-selective electrodes containing lipophilic ionophores are traditionally interrogated by zero current potentiometry, which, ideally, gives information on the sample activity of ionic species. It is shown here that a discrete cathodic current pulse across an H+-selective polymeric membrane doped with the ionophore ETH 5294 may be used for the chronopotentiometric detection of pH in well buffered samples. However, a reduction in the buffer capacity leads to large deviations from the expected Nernstian response slope. This is explained by the local depletion of hydrogen ions at the sample-membrane interface as a result of the galvanostatically imposed ion flux in direction of the membrane. This depletion is found to be a function of the total acidity of the sample and can be directly monitored chronopotentiometrically in a flash titration experiment. The subsequent application of a baseline potential pulse reverses the extraction process of the current pulse, allowing one to interrogate the sample with minimal perturbation. In one protocol, total acidity is found to be proportional to the magnitude of applied current at the flash titration endpoint. More conveniently, the square root of the flash titration endpoint time observed at a fixed applied current is a linear function of the total acid concentration. This suggests that it is possible to perform rapid localized pH titrations at ion-selective electrodes without the need for volumetric titrimetry. The technique is explored here for acetic acid, MES and citric acid with promising results. Polymeric membrane electrodes on the basis of poly(vinyl chloride) plasticized with o-nitrophenyloctylether in a 1:2 mass ratio may be used for the detection of acids of up to ca. 1 mM concentration, with flash titration times on the order of a few seconds. Possible limitations of the technique are discussed, including variations of the acid diffusion coefficients and influence of electrical migration. PMID:18370399

  7. Field ion microscopic studies of the CO oxidation on platinum: Field ion imaging and titration reactions

    NASA Astrophysics Data System (ADS)

    Gorodetskii, V.; Drachsel, W.; Block, J. H.

    1994-05-01

    Elementary steps of the CO oxidation—which are important for understanding the oscillatory behavior of this catalytic reaction—are investigated simultaneously on different Pt-single crystal surfaces by field ion microscopy. Due to preferential ionization probabilities of oxygen as imaging gas on those surface sites, which are adsorbed with oxygen, these sites can be imaged in a lateral resolution on the atomic scale. In the titration reaction a COad-precovered field emitter surface reacts with gaseous oxygen adsorbed from the gas phase or, vice versa, the Oad-precovered surface with carbon monoxide adsorbed from the gas phase. The competition of the manifold of single crystal planes exposed to the titration reaction at the field emitter tip is studied. The surface specificity can be documented in the specific reaction delay times of the different planes and in the propagation rates of the reaction-diffusion wave fronts measured on these individual planes during the titration reaction with a time resolution of 40 ms. At 300 K the COad-precovered surfaces display the {011} regions, precisely the {331} planes as the most active, followed by {012}, {122}, {001}, and finally by {111}. Reaction wave fronts move with a velocity of 8 Å/s at {012}, with ≊0.8 Å/s at {111}, and have a very fast ``switch-on'' reaction at the (001) plane with 500 Å/s. At higher temperature, T=350 K, an acceleration of reaction rates is combined with shorter delay times. The titration reaction of a precovered Oad surface with COgas at T=373 K shows the formation of CO islands starting in the {011} regions with a quickly moving reaction front into the other surface areas without showing particular delay times for different surface symmetries. The two reverse titration reactions have a largely different character. The titration of COad with oxygen adsorbed from the gas phase consists of three different steps, (i) the induction times, (ii) the highly surface specific reaction, and (iii) different rates of wave front propagation. The reaction of COgas with a precovered Oad layer on the other hand starts with nucleating islands around the {011} planes from where the whole emitter surface is populated with COad without pronounced surface specifity.

  8. Measuring titratable alkalinity by single versus double endpoint titration: An evaluation in two cyprinodont species and implications for characterizing net H+ flux in aquatic organisms.

    PubMed

    Brix, Kevin V; Wood, Chris M; Grosell, Martin

    2013-01-01

    In this study, Na(+) uptake and acid-base balance in the euryhaline pupfish Cyprinodon variegatus variegatus were characterized when fish were exposed to pH 4.5 freshwater (7mM Na(+)). Similar to the related cyprinodont, Fundulus heteroclitus, Na(+) uptake was significantly inhibited when exposed to low pH water. However, it initially appeared that C. v. variegatus increased apparent net acid excretion at low pH relative to circumneutral pH. This result is opposite to previous observations for F. heteroclitus under similar conditions where fish were observed to switch from apparent net H(+) excretion at circumneutral pH to apparent net H(+) uptake at low pH. Further investigation revealed disparate observations between these studies were the result of using double endpoint titrations to measure titratable alkalinity fluxes in the current study, while the earlier study utilized single endpoint titrations to measure these fluxes (i.e.,. Cyprinodon acid-base transport is qualitatively similar to Fundulus when characterized using single endpoint titrations). This led to a comparative investigation of these two methods. We hypothesized that either the single endpoint methodology was being influenced by a change in the buffer capacity of the water (e.g., mucus being released by the fish) at low pH, or the double endpoint methodology was not properly accounting for ammonia flux by the fish. A series of follow-up experiments indicated that buffer capacity of the water did not change significantly, that excretion of protein (a surrogate for mucus) was actually reduced at low pH, and that the double endpoint methodology does not properly account for NH(3) excretion by fish under low pH conditions. As a result, it overestimates net H(+) excretion during low pH exposure. After applying the maximum possible correction for this error (i.e., assuming that all ammonia is excreted as NH(3)), the double endpoint methodology indicates that net H(+) transport was reduced to effectively zero in both species at pH 4.5. However, significant differences between the double endpoint (no net H(+) transport at low pH) and single endpoint titrations (net H(+) uptake at low pH) remain to be explained. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Efficacy and safety of weight-based insulin glargine dose titration regimen compared with glucose level- and current dose-based regimens in hospitalized patients with type 2 diabetes: a randomized, controlled study.

    PubMed

    Li, Xiaowei; Du, Tao; Li, Wangen; Zhang, Tong; Liu, Haiyan; Xiong, Yifeng

    2014-09-01

    Insulin glargine is widely used as basal insulin. However, published dose titration regimens for insulin glargine are complex. This study aimed to compare the efficacy and safety profile of a user-friendly, weight-based insulin glargine dose titration regimen with 2 published regimens. A total of 160 hospitalized patients with hyperglycemia in 3 medical centers were screened. Our inclusion criteria included age 18 to 80 years and being conscious. Exclusion criteria included pregnancy or breast-feeding and hepatic or renal dysfunction. A total of 149 patients were randomly assigned to receive weight-based, glucose level-based, or dose-based insulin glargine dose titration regimen between January 2011 and February 2013. The initial dose of insulin glargine was 0.2 U/kg. In the weight-based regimen (n = 49), the dose was titrated by increments of 0.1 U/kg daily. In the glucose level-based regimen (n = 51), the dose was titrated by 2, 4, 6, or 8 U daily when fasting blood glucose (FBG) was, respectively, between 7.0 and 7.9, 8.0 and 8.9, 9.0 and 9.9, or ≥10 mmol/L. In the current dose-based regimen (n = 49), titration was by daily increments of 20% of the current dose. The target FBG in all groups was ≤7.0 mmol/L. The incidence of hypoglycemia was recorded. One-way ANOVA and χ(2) test were used to compare data between the 3 groups. All but 1 patient who required additional oral antidiabetic medication completed the study. The mean (SD) time to achieve target FBG was 3.2 (1.2) days with the weight-based regimen and 3.7 (1.5) days with the glucose level-based regimen (P = 0.266). These times were both shorter than that achieved with the current dose-based regimen (4.8 [2.8] days; P = 0.0001 and P = 0.005, respectively). The daily doses of insulin glargine at the study end point were 0.43 (0.13) U/kg with the weight-based regimen, 0.50 (0.20) U/kg with the glucose level-based regimen, and 0.47 (0.23) U/kg with the current dose-based regimen (P = 0.184). The incidence of hypoglycemia was 4.1%, 2.0%, and 6.3%, respectively (P = 0.557). The currently proposed weight-based insulin glargine dose titration regimen is effective, tolerable, and user-friendly at achieving FBG target levels in hospitalized patients with hyperglycemia. Copyright © 2014 Elsevier HS Journals, Inc. All rights reserved.

  10. Safety of the Up-titration of Nifedipine GITS and Valsartan or Low-dose Combination in Uncontrolled Hypertension: the FOCUS Study.

    PubMed

    Park, Jeong Bae; Shin, Joon-Han; Kim, Dong-Soo; Youn, Ho-Joong; Park, Seung Woo; Shim, Wan Joo; Park, Chang Gyu; Kim, Dong-Woon; Lee, Hae-Young; Choi, Dong-Ju; Rim, Se-Joong; Lee, Sung-Yun; Kim, Ju-Han

    2016-04-01

    Doubling the dose of antihypertensive drugs is necessary to manage hypertension in patients whose disease is uncontrolled. However, this strategy can result in safety issues. This study compared the safety and efficacy of up-titration of the nifedipine gastrointestinal therapeutic system (GITS) with up-titration of valsartan monotherapy; these were also compared with low-dose combinations of the two therapies. This prospective, open-label, randomized, active-controlled, multicenter study lasted 8 weeks. If patients did not meet the target blood pressure (BP) after 4 weeks of treatment with low-dose monotherapy, they were randomized to up-titration of the nifedipine GITS dose from 30 mg (N30) to 60 mg or valsartan from 80 mg to 160 mg or they were randomized to receive a low-dose combination of N30 and valsartan 80 mg for another 4 weeks. BP variability was assessed by using the SD or the %CV of the short-term BP measured at clinic. Of the 391 patients (20~70 years with stage II or higher hypertension) screened for study inclusion, 362 patients who had 3 BP measurements were enrolled. The reduction in the mean systolic/diastolic BP from baseline to week 4 was similar in both low-dose monotherapy groups with either N30 or valsartan 80 mg. BP variability (SD) was unchanged with either therapy, but the %CV was slightly increased in the N30 group. There was no significant difference in BP variability either in SD or %CV between responders and nonresponders to each monotherapy despite the significant difference in the mean BP changes. The up-titration effect of nifedipine GTS from 30 to 60 mg exhibited an additional BP reduction, but this effect was not shown in the up-titration of valsartan from 80 to 160 mg. Although the difference in BP was obvious between high-dose nifedipine GTS and valsartan, the BP variability was unchanged between the 2 drugs and was similar to the low-dose combinations. There was a low rate of adverse events in all treatment groups. In addition, escalating the dose of either nifedipine GITS or valsartan revealed a similar occurrence of adverse effects with low-dose monotherapy or the low-dose combination. Compared with up-titration of the angiotensin receptor blocker valsartan, up-titration of the calcium channel blocker nifedipine GITS provided no additional increased safety concerns and revealed better mean reductions in BP without affecting short-term BP variability. ClinicalTrials.gov identifier: NCT01071122. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  11. The Mobile Insulin Titration Intervention (MITI) for Insulin Adjustment in an Urban, Low-Income Population: Randomized Controlled Trial.

    PubMed

    Levy, Natalie; Moynihan, Victoria; Nilo, Annielyn; Singer, Karyn; Bernik, Lidia S; Etiebet, Mary-Ann; Fang, Yixin; Cho, James; Natarajan, Sundar

    2015-07-17

    Diabetes patients are usually started on a low dose of insulin and their dose is adjusted or "titrated" according to their blood glucose levels. Insulin titration administered through face-to-face visits with a clinician can be time consuming and logistically burdensome for patients, especially those of low socioeconomic status (SES). Given the wide use of mobile phones among this population, there is the potential to use short message service (SMS) text messaging and phone calls to perform insulin titration remotely. The goals of this pilot study were to (1) evaluate if our Mobile Insulin Titration Intervention (MITI) intervention using text messaging and phone calls was effective in helping patients reach their optimal insulin glargine dose within 12 weeks, (2) assess the feasibility of the intervention within our clinic setting and patient population, (3) collect data on the cost savings associated with the intervention, and (4) measure patient satisfaction with the intervention. This was a pilot study evaluating an intervention for patients requiring insulin glargine titration in the outpatient medical clinic of Bellevue Hospital Center in New York City. Patients in the intervention arm received weekday SMS text messages from a health management platform requesting their fasting blood glucose values. The clinic's diabetes nurse educator monitored the texted responses on the platform website each weekday for alarm values. Once a week, the nurse reviewed the glucose values, consulted the MITI titration algorithm, and called patients to adjust their insulin dose. Patients in the usual care arm continued to receive their standard clinic care for insulin titration. The primary outcome was whether a patient reached his/her optimal insulin glargine dose within 12 weeks. A total of 61 patients consented and were randomized into the study. A significantly greater proportion of patients in the intervention arm reached their optimal insulin glargine dose than patients in the usual care arm (88%, 29/33 vs 37%, 10/27; P<.001). Patients responded to 84.3% (420/498) of the SMS text messages requesting their blood glucose values. The nurse reached patients within 2 attempts or by voicemail 91% of the time (90/99 assigned calls). When patients traveled to the clinic, they spent a median of 45 minutes (IQR 30-60) on travel and 39 minutes (IQR 30-64) waiting prior to appointments. A total of 61% (37/61) of patients had appointment copays. After participating in the study, patients in the intervention arm reported higher treatment satisfaction than those in the usual care arm. MITI is an effective way to help low-SES patients reach their optimal insulin glargine dose using basic SMS text messaging and phone calls. The intervention was feasible and patients were highly satisfied with their treatment. The intervention was cost saving in terms of time for patients, who were able to have their insulin titrated without multiple clinic appointments. Similar interventions should be explored to improve care for low-SES patients managing chronic disease. Clinicaltrials.gov NCT01879579; https://clinicaltrials.gov/ct2/show/NCT01879579 (Archived by WebCite at http://www.webcitation.org/6YZik33L3).

  12. The Reduction of Sulfuryl Chloride at Teflon-Bonded Carbon Cathodes.

    DTIC Science & Technology

    1981-01-01

    100C. The cathode was then extracted with a total volume of 100 cc of water and aliquots of the extract titrated potentiometrically with a standardized...S02C12 In an alkaline aqueous solution, S02 or Cl2 when individually dissolved, can be titrated through iodimetry or iodometry, respectively.8 If both

  13. Tested Demonstrations: Buffer Capacity of Various Acetic Acid-Sodium Acetate Systems: A Lecture Experiment.

    ERIC Educational Resources Information Center

    Donahue, Craig J.; Panek, Mary G.

    1985-01-01

    Background information and procedures are provided for a lecture experiment which uses indicators to illustrate the concept of differing buffer capacities by titrating acetic acid/sodium acetate buffers with 1.0 molar hydrochloric acid and 1.0 molar sodium hydroxide. A table with data used to plot the titration curve is included. (JN)

  14. Charge Density Quantification of Polyelectrolyte Polysaccharides by Conductometric Titration: An Analytical Chemistry Experiment

    ERIC Educational Resources Information Center

    Farris, Stefano; Mora, Luigi; Capretti, Giorgio; Piergiovanni, Luciano

    2012-01-01

    An easy analytical method for determination of the charge density of polyelectrolytes, including polysaccharides and other biopolymers, is presented. The basic principles of conductometric titration, which is used in the pulp and paper industry as well as in colloid and interface science, were adapted to quantify the charge densities of a…

  15. Chemical Characterization and Toxicologic Evaluation of Airborne Mixtures

    DTIC Science & Technology

    1981-04-01

    in the chamber air (",50% relative humidity) that phosphoric acid would be the principal component of the...triphosphoric, and tetrametaphosphoric acids were present; trimeta- phosphoric and tetrapolyphosporic acids may also have been present in trace amounts. The...triphosphoric acid , diphosphoric acid , and phosphoric acid are all strong acids that, with strong bases, can be titrated in water. Titration

  16. [Not Available].

    PubMed

    Burgot, J L

    1978-06-01

    Acids conjugated to various phenothiazine derivatives are titrated directly with sodium hydroxide, by means of an automatic thermometric titrimeter. The titration curves have sharp breaks, suitable for analytical use, and these are discussed, in the case of promethazine hydrochloride, as functions of various parameters such as pK(a), the solubility of the product and the enthalpy of neutralization (determined in this work).

  17. Thermometric titration of some monoprotic and diprotic acids in aqueous and non-aqueous media.

    PubMed

    Harries, R J

    1968-12-01

    Some mono- and diprotic acids have been titrated thermometrically with strong alkalis in aqueous and non-aqueous media. Thermograms with sharp arrest points were obtained, from which heats of neutralization were measured. Heats of neutralization in the media used were compared and an effect attributable to hydrogen bonding was found.

  18. Reference test methods for total water in lint cotton by Karl Fischer Titration and low temperature distillation

    USDA-ARS?s Scientific Manuscript database

    In a study of comparability of total water contents (%) of conditioned cottons by Karl Fischer Titration (KFT) and Low Temperature Distillation (LTD) reference methods, we demonstrated a match of averaged results based on a large number of replications and weighing the test specimens at the same tim...

  19. Isothermal Titration Calorimetry and Macromolecular Visualization for the Interaction of Lysozyme and Its Inhibitors

    ERIC Educational Resources Information Center

    Wei, Chin-Chuan; Jensen, Drake; Boyle, Tiffany; O'Brien, Leah C.; De Meo, Cristina; Shabestary, Nahid; Eder, Douglas J.

    2015-01-01

    To provide a research-like experience to upper-division undergraduate students in a biochemistry teaching laboratory, isothermal titration calorimetry (ITC) is employed to determine the binding constants of lysozyme and its inhibitors, N-acetyl glucosamine trimer (NAG[subscript 3]) and monomer (NAG). The extremely weak binding of lysozyme/NAG is…

  20. Using Conductivity Measurements to Determine the Identities and Concentrations of Unknown Acids: An Inquiry Laboratory Experiment

    ERIC Educational Resources Information Center

    Smith, K. Christopher; Garza, Ariana

    2015-01-01

    This paper describes a student designed experiment using titrations involving conductivity measurements to identify unknown acids as being either HCl or H[subscript 2]SO[subscript 4], and to determine the concentrations of the acids, thereby improving the utility of standard acid-base titrations. Using an inquiry context, students gain experience…

  1. Titration of a Solid Acid Monitored by X-Ray Diffraction

    ERIC Educational Resources Information Center

    Dungey, Keenan E.; Epstein, Paul

    2007-01-01

    An experiment is described to introduce students to an important class of solid-state reactions while reinforcing concepts of titration by using a pH meter and a powder X-ray diffractometer. The experiment was successful in teaching students the abstract concepts of solid-state structure and diffraction by applying the diffraction concepts learned…

  2. Differential electrolytic potentiometric titration method for the determination of ciprofloxacin in drug formulations.

    PubMed

    Abulkibash, Abdalla M; Sultan, Salah M; Al-Olyan, Abeer M; Al-Ghannam, Sheikha M

    2003-10-17

    A simple and rapid differential electrolytic potentiometric titration method for the determination of ciprofloxacin was developed. The work is based on the fast complexation reaction between iron(III) and ciprofloxacin in a ratio of 1:3, respectively, in sulfuric acid media of 0.09 mol dm(-3). Among the electrodes tested silver amalgam electrodes were found to be a suitable indicating system. By applying a current density of 0.5 muA cm(-2) to these electrodes and using iron(III) solution of 0.097 mol dm(-3) as a titrant, normal titration curves were obtained. The method was successfully applied for the determination of ciprofloxacin in drug formulations as low as 4.0 ppm.

  3. Colloidal titration of aqueous zirconium solutions with poly(vinyl sulfate) by potentiometric endpoint detection using a toluidine blue selective electrode.

    PubMed

    Sakurada, Osamu; Kato, Yasutake; Kito, Noriyoshi; Kameyama, Keiichi; Hattori, Toshiaki; Hashiba, Minoru

    2004-02-01

    Zirconium oxy-salts were hydrolyzed to form positively charged polymer or cluster species in acidic solutions. The zirconium hydrolyzed polymer was found to react with a negatively charged polyelectrolyte, such as poly(vinyl sulfate), and to form a stoichiometric polyion complex. Thus, colloidal titration with poly(vinyl sulfate) was applied to measure the zirconium concentration in an acidic solution by using a Toluidine Blue selective plasticized poly(vinyl chloride) membrane electrode as a potentiometric end-point detecting device. The determination could be performed with 1% of the relative standard deviation. The colloidal titration stoichiometry at pH < or = 2 was one mol of zirconium per equivalent mol of poly(vinyl sulfate).

  4. Coulometric thermometric titration of halides in molten calcium nitrate tetrahydrate.

    PubMed

    Zsigrai, I J; Bartusz, D B

    1983-01-01

    A method for coulometric thermometric precipitation titrations of chloride, bromide and iodide in molten calcium nitrate tetrahydrate at 55 degrees with coulometrically generated silver ions has been developed. The change in temperature during the titration is followed with the aid of a thermistor bridge coupled to a recorder. To minimize the temperature effect of the passage of current through the melt, two thermistors are connected in opposition in the bridge, with one in the anodic and the other in the cathodic cell compartment. Amounts of 62-80 mumole of halide have been determined with relative error below 0.4% and relative standard deviation less than 2.7%. The relative error in determination of 40 mumole of iodide was + 2%.

  5. Coulometrische titration von hypochloriten und chloraten.

    PubMed

    Gründler, P; Holzapfel, H

    1970-03-01

    Hypochlorite was determined by direct coulometric titration with iron(II) in an acetate buffered solution. Chlorate was titrated with titanium(III) in 2M hydrochloric acid. Amperometric indication with one and two electrodes, respectively, was used. Mixtures of hypochlorites and chlorates, e.g., in industrial electrolytes, may be analysed. On a déterminé l'hypochlorite par titrage coulométrique direct avec le fer(II) dans une solution tamponnée à l'acétate. On a titré le chlorate avec le titane(III) en acide chlorhydrique 2M. On a utilisé l'indication ampérométrique une et deux électrodes respectivement. On peut analyser des mélanges d'hypochlorites et de chlorates, par exemple dans des électrolytes industriels.

  6. Simultaneous addition of two ligands: a potential strategy for estimating divalent ion affinities in EF-hand proteins by isothermal titration calorimetry.

    PubMed

    Henzl, Michael T; Markus, Lindsey A; Davis, Meredith E; McMillan, Andrew T

    2013-03-01

    Capable of providing a detailed thermodynamic picture of noncovalent association reactions, isothermal titration calorimetry (ITC) has become a popular method for studying protein-ligand interactions. We routinely employ the technique to study divalent ion-binding by two-site EF-hand proteins from the parvalbumin- and polcalcin lineages. The combination of high Ca(2+) affinity and relatively low Mg(2+) affinity, and the attendant complication of parameter correlation, conspire to make the simultaneous extraction of binding constants and -enthalpies for both ions challenging. Although global analysis of multiple ITC experiments can overcome these hurdles, our current experimental protocol includes upwards of 10 titrations - requiring a substantial investment in labor, machine time, and material. This paper explores the potential for using a smaller suite of experiments that includes simultaneous titrations with Ca(2+) and Mg(2+) at different ratios of the two ions. The results obtained for four proteins, differing substantially in their divalent ion-binding properties, suggest that the approach has merit. The Ca(2+)- and Mg(2+)-binding constants afforded by the streamlined analysis are in reasonable agreement with those obtained from the standard analysis protocol. Likewise, the abbreviated analysis provides comparable values for the Ca(2+)-binding enthalpies. However, the streamlined analysis can yield divergent values for the Mg(2+)-binding enthalpies - particularly those for lower affinity sites. This shortcoming can be remedied, in large measure, by including data from a direct Ca(2+) titration in the presence of a high, fixed Mg(2+) concentration. Copyright © 2013. Published by Elsevier Inc.

  7. Flow cytometry as an improved method for the titration of Chlamydiaceae and other intracellular bacteria.

    PubMed

    Käser, T; Pasternak, J A; Hamonic, G; Rieder, M; Lai, K; Delgado-Ortega, M; Gerdts, V; Meurens, F

    2016-05-01

    Chlamydiaceae is a family of intracellular bacteria causing a range of diverse pathological outcomes. The most devastating human diseases are ocular infections with C. trachomatis leading to blindness and genital infections causing pelvic inflammatory disease with long-term sequelae including infertility and chronic pelvic pain. In order to enable the comparison of experiments between laboratories investigating host-chlamydia interactions, the infectious titer has to be determined. Titer determination of chlamydia is most commonly performed via microscopy of host cells infected with a serial dilution of chlamydia. However, other methods including fluorescent ELISpot (Fluorospot) and DNA Chip Scanning Technology have also been proposed to enumerate chlamydia-infected cells. For viruses, flow cytometry has been suggested as a superior alternative to standard titration methods. In this study we compared the use of flow cytometry with microscopy and Fluorospot for the titration of C. suis as a representative of other intracellular bacteria. Titer determination via Fluorospot was unreliable, while titration via microscopy led to a linear read-out range of 16 - 64 dilutions and moderate reproducibility with acceptable standard deviations within and between investigators. In contrast, flow cytometry had a vast linear read-out range of 1,024 dilutions and the lowest standard deviations given a basic training in these methods. In addition, flow cytometry was faster and material costs were lower compared to microscopy. Flow cytometry offers a fast, cheap, precise, and reproducible alternative for the titration of intracellular bacteria like C. suis. © 2016 International Society for Advancement of Cytometry. © 2016 International Society for Advancement of Cytometry.

  8. Digital movie-based on automatic titrations.

    PubMed

    Lima, Ricardo Alexandre C; Almeida, Luciano F; Lyra, Wellington S; Siqueira, Lucas A; Gaião, Edvaldo N; Paiva Junior, Sérgio S L; Lima, Rafaela L F C

    2016-01-15

    This study proposes the use of digital movies (DMs) in a flow-batch analyzer (FBA) to perform automatic, fast and accurate titrations. The term used for this process is "Digital movie-based on automatic titrations" (DMB-AT). A webcam records the DM during the addition of the titrant to the mixing chamber (MC). While the DM is recorded, it is decompiled into frames ordered sequentially at a constant rate of 26 frames per second (FPS). The first frame is used as a reference to define the region of interest (ROI) of 28×13pixels and the R, G and B values, which are used to calculate the Hue (H) values for each frame. The Pearson's correlation coefficient (r) is calculated between the H values of the initial frame and each subsequent frame. The titration curves are plotted in real time using the r values and the opening time of the titrant valve. The end point is estimated by the second derivative method. A software written in C language manages all analytical steps and data treatment in real time. The feasibility of the method was attested by application in acid/base test samples and edible oils. Results were compared with classical titration and did not present statistically significant differences when the paired t-test at the 95% confidence level was applied. The proposed method is able to process about 117-128 samples per hour for the test and edible oil samples, respectively, and its precision was confirmed by overall relative standard deviation (RSD) values, always less than 1.0%. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Heat shock protein expression as guidance for the therapeutic window of retinal laser therapy

    NASA Astrophysics Data System (ADS)

    Wang, Jenny; Huie, Philip; Dalal, Roopa; Lee, Seungjun; Tan, Gavin; Lee, Daeyoung; Lavinksy, Daniel; Palanker, Daniel

    2016-03-01

    Unlike conventional photocoagulation, non-damaging retinal laser therapy (NRT) limits laser-induced heating to stay below the retinal damage threshold and therefore requires careful dosimetry. Without the adverse effects associated with photocoagulation, NRT can be applied to critical areas of the retina and repeatedly to manage chronic disorders. Although the clinical benefits of NRT have been demonstrated, the mechanism of therapeutic effect and width of the therapeutic window below damage threshold are not well understood. Here, we measure activation of heat shock response via laser-induced hyperthermia as one indication of cellular response. A 577 nm laser is used with the Endpoint Management (EpM) user interface, a titration algorithm, to set experimental pulse energies relative to a barely visible titration lesion. Live/dead staining and histology show that the retinal damage threshold in rabbits is at 40% of titration energy on EpM scale. Heat shock protein 70 (HSP70) expression in the retinal pigment epithelium (RPE) was detected by whole-mount immunohistochemistry after different levels of laser treatment. We show HSP70 expression in the RPE beginning at 25% of titration energy indicating that there is a window for NRT between 25% and 40% with activation of the heat shock protein expression in response to hyperthermia. HSP70 expression is also seen at the perimeter of damaging lesions, as expected based on a computational model of laser heating. Expression area for each pulse energy setting varied between laser spots due to pigmentation changes, indicating the relatively narrow window of non-damaging activation and highlighting the importance of proper titration.

  10. Acidic beverages increase the risk of in vitro tooth erosion

    PubMed Central

    Ehlen, Leslie A.; Marshall, Teresa A.; Qian, Fang; Wefel, James S.; Warren, John J.

    2008-01-01

    Acidic beverages are thought to increase the potential for dental erosion. We report pH and titratable acidities (i.e., quantity of base required to bring a solution to neutral pH) of beverages popular in the United States and lesion depths in enamel and root surfaces following beverage exposure, and we describe associations among pH, titratable acidity and both enamel and root erosive lesion depths. The pH of 100% juices, regular sodas, diet sodas and sports drinks upon opening, and the titratable acidity both upon opening and after 60 minutes of stirring were measured. Enamel and root surfaces of healthy permanent molars and premolars were exposed to individual beverages (4 enamel and 4 root surfaces per beverage) for 25 hours and erosion was measured. Statistical analyses included two-sample t-tests, analyses of variance with post hoc Tukey’s studentized range test; and Spearman rank correlation coefficients. All beverages were acidic; the titratable acidity of energy drinks was greater than regular sodas and diet sodas which were greater than 100% juices and sports drinks (P<0.05). Enamel lesion depths following beverage exposures were greatest for Gatorade® followed by Red Bull® and Coke® which were greater than Diet Coke® and 100% apple juice (P <0.05). Root lesion depths were greatest for Gatorade® followed by Red Bull®, Coke®, 100% apple juice and Diet Coke® (P<0.05). Lesion depths were not associated with pH or titratable acidity. Beverages popular in the United States can produce dental erosion. PMID:19083423

  11. 3-D Surface Visualization of pH Titration "Topos": Equivalence Point Cliffs, Dilution Ramps, and Buffer Plateaus

    ERIC Educational Resources Information Center

    Smith, Garon C.; Hossain, Md Mainul; MacCarthy, Patrick

    2014-01-01

    3-D topographic surfaces ("topos") can be generated to visualize how pH behaves during titration and dilution procedures. The surfaces are constructed by plotting computed pH values above a composition grid with volume of base added in one direction and overall system dilution on the other. What emerge are surface features that…

  12. Volumetric Titrations Using Electrolytically Generated Reagents for the Determination of Ascorbic Acid and Iron in Dietary Supplement Tablets: An Undergraduate Laboratory Experiment

    ERIC Educational Resources Information Center

    Scanlon, Christopher; Gebeyehu, Zewdu; Griffin, Kameron; Dabke, Rajeev B.

    2014-01-01

    An undergraduate laboratory experiment for the volumetric quantitative analysis of ascorbic acid and iron in dietary supplement tablets is presented. Powdered samples of the dietary supplement tablets were volumetrically titrated against electrolytically generated reagents, and the mass of dietary reagent in the tablet was determined from the…

  13. Reference method for total water in lint cotton by automated oven drying combined with volumetric Karl Fischer titration

    USDA-ARS?s Scientific Manuscript database

    In a preliminary study to measure total water in lint cotton we demonstrated that volumetric Karl Fischer Titration of moisture transported by a carrier gas from an attached small oven is more accurate than standard oven drying in air. The objective of the present study was to assess the measuremen...

  14. Kinetic properties of two Rhizopus exo-polygalacturonase enzymes hydrolyzing galacturonic acid oligomers using isothermal titration calorimetry

    USDA-ARS?s Scientific Manuscript database

    The kinetic characteristics of two Rhizopus oryzae exo-polygalacturonases acting on galacturonic acid oligomers (GalpA) were determined using isothermal titration calorimetry (ITC). RPG15 hydrolyzing (GalpA)2 demonstrated a Km of 55 uM and kcat of 10.3 s^-1^ while RPG16 was shown to have greater af...

  15. The Sound and Feel of Titrations: A Smartphone Aid for Color-Blind and Visually Impaired Students

    ERIC Educational Resources Information Center

    Bandyopadhyay, Subhajit; Rathod, Balraj B.

    2017-01-01

    An Android-based application has been developed to provide color-blind and visually impaired students a multisensory perception of color change observed in a titration. The application records and converts the color information into beep sounds and vibration pulses, which are generated by the smartphone. It uses a range threshold of hue and…

  16. Complexation Effect on Redox Potential of Iron(III)-Iron(II) Couple: A Simple Potentiometric Experiment

    ERIC Educational Resources Information Center

    Rizvi, Masood Ahmad; Syed, Raashid Maqsood; Khan, Badruddin

    2011-01-01

    A titration curve with multiple inflection points results when a mixture of two or more reducing agents with sufficiently different reduction potentials are titrated. In this experiment iron(II) complexes are combined into a mixture of reducing agents and are oxidized to the corresponding iron(III) complexes. As all of the complexes involve the…

  17. Utilizing the virus-induced blocking of apoptosis in an easy baculovirus titration method

    PubMed Central

    Niarchos, Athanasios; Lagoumintzis, George; Poulas, Konstantinos

    2015-01-01

    Baculovirus-mediated protein expression is a robust experimental technique for producing recombinant higher-eukaryotic proteins because it combines high yields with considerable post-translational modification capabilities. In this expression system, the determination of the titer of recombinant baculovirus stocks is important to achieve the correct multiplicity of infection for effective amplification of the virus and high expression of the target protein. To overcome the drawbacks of existing titration methods (e.g., plaque assay, real-time PCR), we present a simple and reliable assay that uses the ability of baculoviruses to block apoptosis in their host cells to accurately titrate virus samples. Briefly, after incubation with serial dilutions of baculovirus samples, Sf9 cells were UV irradiated and, after apoptosis induction, they were viewed via microscopy; the presence of cluster(s) of infected cells as islets indicated blocked apoptosis. Subsequently, baculovirus titers were calculated through the determination of the 50% endpoint dilution. The method is simple, inexpensive, and does not require unique laboratory equipment, consumables or expertise; moreover, it is versatile enough to be adapted for the titration of every virus species that can block apoptosis in any culturable host cells which undergo apoptosis under specific conditions. PMID:26490731

  18. Titration of biologically active amyloid–β seeds in a transgenic mouse model of Alzheimer's disease

    PubMed Central

    Morales, Rodrigo; Bravo-Alegria, Javiera; Duran-Aniotz, Claudia; Soto, Claudio

    2015-01-01

    Experimental evidence in animal models suggests that misfolded Amyloid-β (Aβ) spreads in disease following a prion-like mechanism. Several properties characteristics of infectious prions have been shown for the induction of Aβ aggregates. However, a detailed titration of Aβ misfolding transmissibility and estimation of the minimum concentration of biologically active Aβ seeds able to accelerate pathological changes has not yet been performed. In this study, brain extracts from old tg2576 animals were serially diluted and intra-cerebrally injected into young subjects from the same transgenic line. Animals were sacrificed several months after treatment and brain slices were analyzed for amyloid pathology. We observed that administration of misfolded Aβ was able to significantly accelerate amyloid deposition in young mice, even when the original sample was diluted a million times. The titration curve obtained in this experiment was compared to the natural Aβ load spontaneously accumulated by these mice overtime. Our findings suggest that administration of the largest dose of Aβ seeds led to an acceleration of pathology equivalent to over a year. These results show that active Aβ seeds present in the brain can seed amyloidosis in a titratable manner, similarly as observed for infectious prions. PMID:25879692

  19. Four points function fitted and first derivative procedure for determining the end points in potentiometric titration curves: statistical analysis and method comparison.

    PubMed

    Kholeif, S A

    2001-06-01

    A new method that belongs to the differential category for determining the end points from potentiometric titration curves is presented. It uses a preprocess to find first derivative values by fitting four data points in and around the region of inflection to a non-linear function, and then locate the end point, usually as a maximum or minimum, using an inverse parabolic interpolation procedure that has an analytical solution. The behavior and accuracy of the sigmoid and cumulative non-linear functions used are investigated against three factors. A statistical evaluation of the new method using linear least-squares method validation and multifactor data analysis are covered. The new method is generally applied to symmetrical and unsymmetrical potentiometric titration curves, and the end point is calculated using numerical procedures only. It outperforms the "parent" regular differential method in almost all factors levels and gives accurate results comparable to the true or estimated true end points. Calculated end points from selected experimental titration curves compatible with the equivalence point category of methods, such as Gran or Fortuin, are also compared with the new method.

  20. Estimation of uncertainty in pKa values determined by potentiometric titration.

    PubMed

    Koort, Eve; Herodes, Koit; Pihl, Viljar; Leito, Ivo

    2004-06-01

    A procedure is presented for estimation of uncertainty in measurement of the pK(a) of a weak acid by potentiometric titration. The procedure is based on the ISO GUM. The core of the procedure is a mathematical model that involves 40 input parameters. A novel approach is used for taking into account the purity of the acid, the impurities are not treated as inert compounds only, their possible acidic dissociation is also taken into account. Application to an example of practical pK(a) determination is presented. Altogether 67 different sources of uncertainty are identified and quantified within the example. The relative importance of different uncertainty sources is discussed. The most important source of uncertainty (with the experimental set-up of the example) is the uncertainty of pH measurement followed by the accuracy of the burette and the uncertainty of weighing. The procedure gives uncertainty separately for each point of the titration curve. The uncertainty depends on the amount of titrant added, being lowest in the central part of the titration curve. The possibilities of reducing the uncertainty and interpreting the drift of the pK(a) values obtained from the same curve are discussed.

  1. The efficacy of three different mask styles on a PAP titration night.

    PubMed

    Ebben, Matthew R; Oyegbile, Temitayo; Pollak, Charles P

    2012-06-01

    This study compared the efficacy of three different masks, nasal pillows, nasal masks and full face (oronasal) masks, during a single night of titration with continuous positive airway pressure (CPAP). Fifty five subjects that included men (n=33) and women (n=22) were randomly assigned to one of three masks and underwent a routine titration with incremental CPAP applied through the different masks. CPAP applied through the nasal pillows and nasal mask was equally effective in treating mild, moderate, and severe sleep apnea. However, CPAP applied through the oronasal mask required a significantly higher pressure compared to nasal masks to treat moderately severe (2.8 cm of H(2)O ± 2.1 SD) and severe (6.0 cm of H(2)O ± 3.2 SD) obstructive sleep apnea. CPAP applied with either nasal mask was effective in treating mild, moderate, and severe sleep apnea. The oronasal mask required significantly higher pressures in subjects with moderate to severe disease. Therefore, when changing from a nasal to an oronasal mask, a repeat titration is required to ensure effective treatment of sleep apnea, especially in patients with moderate to severe disease. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Quantifying accessible sites and reactivity on titania–silica (photo)catalysts: Refining TOF calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eaton, Todd R.; Campos, Michael P.; Gray, Kimberly A.

    2014-01-01

    It can be difficult to determine the number of active atoms accessible to the fluid phase in mixed oxide catalysts, as required for obtaining true turnover frequencies (TOF). Here, we utilize the selective titration of surface Ti atoms with phenylphosphonic acid (PPA) on TiO 2–SiO 2 materials to estimate the number of reactant-accessible sites. TiO 2–SiO 2 composites were synthesized over a range of Ti loadings from grafting of titanocene dichloride (Cp 2TiCl 2) or tetraethoxy orthotitanate (TEOT) on SiO 2 and sol–gel co-hydrolysis of Si and Ti alkoxides. The materials were characterized by DRUV–vis, XRD, BET, and XANES. Despitemore » the significant morphological and electronic differences, materials prepared by Cp 2TiCl 2 and TEOT yielded a near-constant TOF of 0.14 h -1 (±0.04) across Ti loadings, for benzyl alcohol photooxidation, when normalizing rates by sites titrated by PPA. The fraction of Ti atoms titrated by PPA was strongly dependent on synthesis method and surface density. PPA titration and benzyl alcohol photooxidation may be useful measures of surface accessibility in other supported oxides.« less

  3. A rapid Q-PCR titration protocol for adenovirus and helper-dependent adenovirus vectors that produces biologically relevant results

    PubMed Central

    Gallaher, Sean D.; Berk, Arnold J.

    2013-01-01

    Adenoviruses are employed in the study of cellular processes and as expression vectors used in gene therapy. The success and reproducibility of these studies is dependent in part on having accurate and meaningful titers of replication competent and helper-dependent adenovirus stocks, which is problematic due to the use of varied and divergent titration protocols. Physical titration methods, which quantify the total number of viral particles, are used by many, but are poor at estimating activity. Biological titration methods, such as plaque assays, are more biologically relevant, but are time consuming and not applicable to helper-dependent gene therapy vectors. To address this, a protocol was developed called “infectious genome titration” in which viral DNA is isolated from the nuclei of cells ~3 h post-infection, and then quantified by Q-PCR. This approach ensures that only biologically active virions are counted as part of the titer determination. This approach is rapid, robust, sensitive, reproducible, and applicable to all forms of adenovirus. Unlike other Q-PCR-based methods, titers determined by this protocol are well correlated with biological activity. PMID:23624118

  4. Determining the folding and binding free energy of DNA-based nanodevices and nanoswitches using urea titration curves

    PubMed Central

    Idili, Andrea

    2017-01-01

    Abstract DNA nanotechnology takes advantage of the predictability of DNA interactions to build complex DNA-based functional nanoscale structures. However, when DNA functional and responsive units that are based on non-canonical DNA interactions are employed it becomes quite challenging to predict, understand and control their thermodynamics. In response to this limitation, here we demonstrate the use of isothermal urea titration experiments to estimate the free energy involved in a set of DNA-based systems ranging from unimolecular DNA-based nanoswitches to more complex DNA folds (e.g. aptamers) and nanodevices. We propose here a set of fitting equations that allow to analyze the urea titration curves of these DNA responsive units based on Watson–Crick and non-canonical interactions (stem-loop, G-quadruplex, triplex structures) and to correctly estimate their relative folding and binding free energy values under different experimental conditions. The results described herein will pave the way toward the use of urea titration experiments in the field of DNA nanotechnology to achieve easier and more reliable thermodynamic characterization of DNA-based functional responsive units. More generally, our results will be of general utility to characterize other complex supramolecular systems based on different biopolymers. PMID:28605461

  5. Zinc sorption to three gram-negative bacteria: combined titration, modeling, and EXAFS study.

    PubMed

    Guiné, V; Spadini, L; Sarret, G; Muris, M; Delolme, C; Gaudet, J P; Martins, J M F

    2006-03-15

    The acid-base and Zn sorption properties of three bacteria, Cupriavidus metallidurans CH34, Pseudomonas putida ATCC12633, and Escherichia coli K12DH5alpha, were investigated through an original combination of extended X-ray absorption fine structure (EXAFS) spectroscopy and equilibrium titration studies. Acid-base titration curves of the three strains were fitted with a model accounting for three conceptual reactive sites: an acidic (carboxyl and/or phosphodiester), a neutral (phosphomonoester), and a basic (amine and/or hydroxyl) group. Calculated proton and Zn equilibrium constants and site densities compare with literature data. The nature of Zn binding sites was studied by EXAFS spectroscopy. Phosphoester, carboxyl, and unexpectedly sulfhydryl ligands were identified. Their proportions depended on Zn loading and bacterial strain and were consistent with the titration results. These findings were compared to the structure and site density of the major cell wall components. It appeared that the cumulated theoretical site density of these structures (<2 Zn nm(-2)) was much lower than the total site density of the investigated strains (16-56 Zn nm(-2)). These results suggest a dominant role of extracellular polymeric substances in Zn retention processes, although Zn binding to inner cell components cannot be excluded.

  6. Charge-Neutral Constant pH Molecular Dynamics Simulations Using a Parsimonious Proton Buffer.

    PubMed

    Donnini, Serena; Ullmann, R Thomas; Groenhof, Gerrit; Grubmüller, Helmut

    2016-03-08

    In constant pH molecular dynamics simulations, the protonation states of titratable sites can respond to changes of the pH and of their electrostatic environment. Consequently, the number of protons bound to the biomolecule, and therefore the overall charge of the system, fluctuates during the simulation. To avoid artifacts associated with a non-neutral simulation system, we introduce an approach to maintain neutrality of the simulation box in constant pH molecular dynamics simulations, while maintaining an accurate description of all protonation fluctuations. Specifically, we introduce a proton buffer that, like a buffer in experiment, can exchange protons with the biomolecule enabling its charge to fluctuate. To keep the total charge of the system constant, the uptake and release of protons by the buffer are coupled to the titration of the biomolecule with a constraint. We find that, because the fluctuation of the total charge (number of protons) of a typical biomolecule is much smaller than the number of titratable sites of the biomolecule, the number of buffer sites required to maintain overall charge neutrality without compromising the charge fluctuations of the biomolecule, is typically much smaller than the number of titratable sites, implying markedly enhanced simulation and sampling efficiency.

  7. Effects of fentanyl administration before induction of anesthesia and placement of the Laryngeal Mask Airway: a randomized, placebo-controlled trial.

    PubMed

    Joshi, Girish P; Kamali, Amin; Meng, Jin; Rosero, Eric; Gasanova, Irina

    2014-03-01

    To assess the effects of fentanyl administered before induction of anesthesia on movement and airway responses during desflurane anesthesia via the Laryngeal Mask Airway (LMA). Randomized, double-blinded, controlled trial. Tertiary-care academic center. 100 adult, ASA physical status 1, 2, and 3 patients undergoing ambulatory surgery. Patients were administered fentanyl 1 μg/kg (n=51) or saline (n=49) 3 to 5 minutes before induction with propofol 2-2.5 mg/kg intravenously (IV), followed by LMA placement. Anesthesia was maintained with desflurane titrated to a bispectral index (BIS) of 50-60 and 50% nitrous oxide in oxygen, and fentanyl 25 μg boluses were titrated to respiratory rate. Apnea occurrence and duration of manual ventilation, as well as frequency and severity of movement, coughing, breath holding, and laryngospasm were recorded. Two patients in each group were excluded from analysis. The fentanyl pretreatment group had a higher frequency of apnea (94% vs 64%; P=0.0003) and longer duration of manual ventilation (3 [interquartile range (IQR), 1.5-5] min vs 1 [0-1.5] min; P<0.0001) at induction. In contrast, the fentanyl pretreatment group had a lower frequency of movements (16% vs 51%;P=0.0001). The rates of intraoperative breath holding (6.1% vs 8.5%) and laryngospasm (2% vs 4.3%) in the two groups were similar. All subjects experiencing laryngospasm were smokers. Adjusting for smoking status did not affect the differences noted in apnea, duration of manual ventilation, or movement between groups; however, coughing occurrence was statistically higher in the placebo group (P=0.043). Preinduction fentanyl increased the frequency of apnea at induction and duration of manual ventilation, but reduced the frequency of movements. In addition, it reduced intraoperative coughing in smokers. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Theoretical considerations and a simple method for measuring alkalinity and acidity in low-pH waters by gran titration

    USGS Publications Warehouse

    Barringer, J.L.; Johnsson, P.A.

    1996-01-01

    Titrations for alkalinity and acidity using the technique described by Gran (1952, Determination of the equivalence point in potentiometric titrations, Part II: The Analyst, v. 77, p. 661-671) have been employed in the analysis of low-pH natural waters. This report includes a synopsis of the theory and calculations associated with Gran's technique and presents a simple and inexpensive method for performing alkalinity and acidity determinations. However, potential sources of error introduced by the chemical character of some waters may limit the utility of Gran's technique. Therefore, the cost- and time-efficient method for performing alkalinity and acidity determinations described in this report is useful for exploring the suitability of Gran's technique in studies of water chemistry.

  9. Determination of binding constants of cyclodextrin inclusion complexes with amino acids and dipeptides by potentiometric titration.

    PubMed

    Kahle, Claudia; Holzgrabe, Ulrike

    2004-10-01

    Cyclodextrins are well known for their ability to separate enantiomers of drugs, natural products, and other chiral substances using HPLC, GC, or CE. The resolution of the enantiomers is due to the formation of diastereomeric complexes between the cyclodextrin and the pairs of enantiomers. The aim of this study was to determine the binding constants of the complexes between alpha- and beta-cyclodextrin and the enantiomers of a series of aliphatic and aromatic amino acids, and dipeptides, using a potentiometric titration method. The results of this method are compared to other methods, and correlated to findings in cyclodextrin-modified capillary electrophoresis and possible complex structures. Potentiometric titration was found to be an appropriate tool to determine the binding constants of cyclodextrin inclusion complexes.

  10. Application of cause-and-effect analysis to potentiometric titration.

    PubMed

    Kufelnicki, A; Lis, S; Meinrath, G

    2005-08-01

    A first attempt has been made to interpret physicochemical data from potentiometric titration analysis in accordance with the complete measurement-uncertainty budget approach (bottom-up) of ISO and Eurachem. A cause-and-effect diagram is established and discussed. Titration data for arsenazo III are used as a basis for this discussion. The commercial software Superquad is used and applied within a computer-intensive resampling framework. The cause-and-effect diagram is applied to evaluation of seven protonation constants of arsenazo III in the pH range 2-10.7. The data interpretation is based on empirical probability distributions and their analysis by second-order correct confidence estimates. The evaluated data are applied in the calculation of a speciation diagram including uncertainty estimates using the probabilistic speciation software Ljungskile.

  11. Volumetric determination of uranium titanous sulfate as reductant before oxidimetric titration

    USGS Publications Warehouse

    Wahlberg, J.S.; Skinner, D.L.; Rader, L.F.

    1957-01-01

    Need for a more rapid volumetric method for the routine determination of uranium in uranium-rich materials has led to the development of a method that uses titanous sulfate as a reductant before oxidimetric titration. Separation of the hydrogen sulfide group is not necessary. Interfering elements precipitated by cupferron are removed by automatic filtrations made simultaneously rather than by the longer chloroform extraction method. Uranium is reduced from VI to IV by addition of an excess of titanous sulfate solution, cupric ion serving as an indicator by forming red metallic copper when reduction is complete. The copper is reoxidized by addition of mercuric perchlorate. The reduced uranium is then determined by addition of excess ferric sulfate and titration with ceric sulfate. The method has proved to be rapid, accurate, and economical.

  12. Study of the adhesion of neurodegenerative proteins on plasma-modified and coated polypropylene surfaces.

    PubMed

    Poncin-Epaillard, F; Mille, C; Debarnot, D; Zorzi, W; El Moualij, B; Coudreuse, A; Legeay, G; Quadrio, I; Perret-Liaudet, A

    2012-01-01

    The inner polymeric surface of an ELISA titration well is plasma-modified and coated with different surfactant molecules. The titration of neurodegenerative proteins markers (prion, Tau and β-synuclein), previously demonstrated as more efficient with such modified tubes, is related to the adhesion behaviour of these proteins and their corresponding capture antibodies. The adhesion process is studied in terms of anchoring and specific mechanisms. The proteins and antibodies binding onto such modified surfaces is related to the substrate hydrophilic character calculated from the angle contact measure, to the polymer surface charge measured through the streaming potential determination at different pH and the inner surface roughness determined from AFM images. Furthermore, the influence of the blocking agent used during the ELISA titration is also studied.

  13. Immunochemical Parameters of Some Commercial Conjugates for the Fluorescent Treponemal Antibody-Absorption Test

    PubMed Central

    Hunter, E. F.; Smith, J. F.; Lewis, J. S.; McGrew, B. E.; Schmale, J. D.

    1972-01-01

    Fluorescein-labeled anti-human globulins were examined to determine the need for standardization of conjugates used in the fluorescent treponemal antibody-absorption (FTA-ABS) test. Twenty-one of 33 conjugates submitted by commercial manufacturers to the Reagents Control Activity, Venereal Disease Research Laboratory, for evaluation in the FTA-ABS test were available for study. Conjugates, after evaluation in FTA-ABS performance tests, were examined by immunoelectrophoresis, by titration against immunoglobulins G and M (IgG, IgM) with FTA-ABS techniques, and by the biuret protein and fluorescein diacetate methods for determining fluorescein to protein (F/P) ratios. The conjugates were predominately anti-IgG globulin with anti-light-chain activity. Differences were noted in the ability of some conjugates to detect IgM antibody. The F/P ratios of those conjugates that could be determined varied from 2.6 to 17.8 μg of fluorescein per mg of protein. The need to identify and standardize both the immunologic capabilities and the optimum F/P ratio for FTA-ABS test conjugates is presented. PMID:4564403

  14. Constants and thermodynamics of the acid-base equilibria of triglycine in water-ethanol solutions containing sodium perchlorate at 298 K

    NASA Astrophysics Data System (ADS)

    Pham Tkhi, L.; Usacheva, T. R.; Tukumova, N. V.; Koryshev, N. E.; Khrenova, T. M.; Sharnin, V. A.

    2016-02-01

    The acid-base equilibrium constants for glycyl-glycyl-glycine (triglycine) in water-ethanol solvents containing 0.0, 0.1, 0.3, and 0.5 mole fractions of ethanol are determined by potentiometric titration at 298.15 K and an ionic strength of 0.1, maintained with sodium perchlorate. It is established that an increase in the ethanol content in the solvent reduces the dissociation constant of the carboxyl group of triglycine (increases p K 1) and increases the dissociation constant of the amino group of triglycine (decreases p K 2). It is noted that the weakening of the acidic properties of a triglycinium ion upon an increase of the ethanol content in the solvent is due to the attenuation of the solvation shell of the zwitterionic form of triglycine, and to the increased solvation of triglycinium ions. It is concluded that the acid strength of triglycine increases along with a rise in the EtOH content in the solvent, due to the desolvation of the tripeptide zwitterion and the enhanced solvation of protons.

  15. Permeability of latex gloves after contact with dental materials.

    PubMed

    Richards, J M; Sydiskis, R J; Davidson, W M; Josell, S D; Lavine, D S

    1993-09-01

    The use of latex examination gloves in the dental office has become the standard of care. However, the effectiveness of gloves as a barrier after coming into contact with specific dental materials is still uncertain. To examine the effects of dental materials is still uncertain. To examine the effects of dental materials on latex, 100 latex examination glove finger tips were divided into 10 groups. Each group was manipulated in a different dental material for 15 minutes. Permeability was detected by the passage of herpes virus across the latex membrane, rinsed from the inner glove surface and titrated onto Vero cells. Significant virus leakage was discovered in gloves treated with acrylic monomer, chloroform, and orange solvent. Little virus leakage was noted in bleach, soap, and 30% phosphoric acid etchant treated gloves, and no virus leakage was found with composite resin, ethanol, formocresol, and water treated gloves. These data were supported with scanning electron micrographs taken of the treated glove samples and comparing with the controls. When certain dental materials are manipulated while wearing gloves, irreversible damage to the material occurs and may increase the practitioner's exposure to pathogens.

  16. Thermometric titration of acids in pyridine.

    PubMed

    Vidal, R; Mukherjee, L M

    1974-04-01

    Thermometric titration of HClO(4), HI, HNO(3), HBr, picric acid o-nitrobenzoic acid, 2,4- and 2,5-dinitrophenol, acetic acid and benzoic acid have been attempted in pyridine as solvent, using 1,3-diphenylguanidine as the base. Except in the case of 2,5-dinitrophenol, acetic acid and benzoic acid, the results are, in general, reasonably satisfactory. The approximate molar heats of neutralization have been calculated.

  17. Tunicamycin Enhances Neuroinvasion and Pathogenicity in Mice with Venezuelan Equine Encephalitis Virus

    DTIC Science & Technology

    2003-01-01

    H. Analytical Tests 35 1. Virus Titrations 35 2. RNA Analysis 37 3. Determination of TNF-a and Total Nitrite Levels 37...fluorescent microscope. H. Analytical Tests 1. Virus Titrations For determination of virus titers, brain samples were homogenized in Eppendorf tubes...tissues were mounted on silane-coated slides (Sigma Diagnostics , St. Louis, MO) and labeled for VEE virus antigen by immunohistochemistry. Additional

  18. Determination of hydroxide and carbonate contents of alkaline electrolytes containing zinc

    NASA Technical Reports Server (NTRS)

    Otterson, D. A.

    1975-01-01

    A method to prevent zinc interference with the titration of OH- and CO3-2 ions in alkaline electrolytes with standard acid is presented. The Ba-EDTA complex was tested and shown to prevent zinc interference with acid-base titrations without introducing other types of interference. Theoretical considerations indicate that this method can be used to prevent interference by other metals.

  19. Surface-Bound Intermediates in Low-Temperature Methanol Synthesis on Copper. Participants and Spectators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Yong; Mei, Donghai; Peden, Charles H.F.

    The reactivity of surface adsorbed species present on copper catalysts during methanol synthesis at low temperatures was studied by simultaneous infrared spectroscopy (IR) and mass spectroscopy (MS) measurements during “titration” (transient surface reaction) experiments with isotopic tracing. The results show that adsorbed formate is a major bystander species present on the surface under steady-state methanol synthesis reaction conditions, but it cannot be converted to methanol by reaction with pure H 2, nor with H 2 plus added water. Formate-containing surface adlayers for these experiments were produced during steady state catalysis in (a) H 2:CO 2 (with substantial formate coverage) andmore » (b) moist H 2:CO (with no IR visible formate species). Both these reaction conditions produce methanol at steady state with relatively high rates. Adlayers containing formate were also produced by (c) formic acid adsorption. Various "titration" gases were used to probe these adlayers at modest temperatures (T = 410-450K) and 6 bar total pressure. Methanol gas (up to ~1% monolayer equivalent) was produced in "titration" from the H 2:CO 2 catalytic adlayers by H 2 plus water, but not by dry hydrogen. The decay in the formate IR features accelerated in the presence of added water vapor. The H 2:CO:H 2O catalytic adlayer produced similar methanol titration yields in H 2 plus water but showed no surface formate features in IR (less than 0.2% monolayer coverage). Finally, formate from formic acid chemisorption produced no methanol under any titration conditions. Even under (H 2:CO 2) catalytic reaction conditions, isotope tracing showed that pre-adsorbed formate from formic acid did not contribute to the methanol produced. Although non-formate intermediates exist during low temperature methanol synthesis on copper which can be converted to methanol gas by titration with pure H 2 plus water in sufficient quantities for that intermediate to be observable by IR, formate itself is only a "spectator" in this reaction and gives no observable methanol upon any titration we performed with H 2 or H 2 plus water.« less

  20. Effects of Epoetin Alfa Titration Practices, Implemented After Changes to Product Labeling, on Hemoglobin Levels, Transfusion Use, and Hospitalization Rates.

    PubMed

    Molony, Julia T; Monda, Keri L; Li, Suying; Beaubrun, Anne C; Gilbertson, David T; Bradbury, Brian D; Collins, Allan J

    2016-08-01

    Little is known about epoetin alfa (EPO) dosing at dialysis centers after implementation of the US Medicare prospective payment system and revision of the EPO label in 2011. Retrospective cohort study. Approximately 412,000 adult hemodialysis patients with Medicare Parts A and B as primary payer in 2009 to 2012 to describe EPO dosing and hemoglobin patterns; of these, about 70,000 patients clustered in about 1,300 dialysis facilities to evaluate facility-level EPO titration practices and patient-level outcomes in 2012. Facility EPO titration practices when hemoglobin levels were <10 and >11g/dL (grouped treatment variable) determined from monthly EPO dosing and hemoglobin level patterns. Patient mean hemoglobin levels, red blood cell transfusion rates, and all-cause and cause-specific hospitalization rates using a facility-based analysis. Monthly EPO dose and hemoglobin level, red blood cell transfusion rates, and all-cause and cause-specific hospitalization rates. Monthly EPO doses declined across all hemoglobin levels, with the greatest decline in patients with hemoglobin levels < 10g/dL (July-October 2011). In 2012, nine distinct facility titration practices were identified. Across groups, mean hemoglobin levels differed slightly (10.5-10.8g/dL) but within-patient hemoglobin standard deviations were similar (∼0.68g/dL). Patients at facilities implementing greater dose reductions and smaller dose escalations had lower hemoglobin levels and higher transfusion rates. In contrast, patients at facilities that implemented greater dose escalations (and large or small dose reductions) had higher hemoglobin levels and lower transfusion rates. There were no clinically meaningful differences in all-cause or cause-specific hospitalization events across groups. Possibly incomplete claims data; excluded small facilities and those without consistent titration patterns; hemoglobin levels reported monthly; inferred facility practice from observed dosing. Following prospective payment system implementation and labeling revisions, EPO doses declined significantly. Under the new label, facility EPO titration practices were associated with mean hemoglobin levels (but not standard deviations) and transfusion use, but not hospitalization rates. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  1. "Why not stoichiometry" versus "Stoichiometry--why not?" Part II: GATES in context with redox systems.

    PubMed

    Michałowska-Kaczmarczyk, Anna Maria; Asuero, Agustin G; Toporek, Marcin; Michałowski, Tadeusz

    2015-01-01

    Redox equilibria and titration play an important role in chemical analysis, and the formulation of an accurate mathematical description is a challenge. This article is devoted to static and (mainly) dynamic redox systems; the dynamic systems are represented by redox titrations. An overview addresses earlier approaches to static redox systems (redox diagram plots, including Pourbaix diagrams) and to titration redox systems, thereby covering a gap in the literature. After this short review, the generalized approach to electrolytic systems (GATES) is introduced, with generalized electron balance (GEB) as its inherent part within GATES/GEB. Computer simulation, performed according to GATES/GEB, enables following the changes in potential and pH of the solution, together with chemical speciation at each step of a titration, thus providing better insight into this procedure. The undeniable advantages of GATES/GEB over earlier approaches are indicated. Formulation of GEB according to two approaches (I and II) is presented on the respective examples. A general criterion distinguishing between non-redox and redox systems is presented. It is indicated that the formulation of GEB according to Approach II does not need the knowledge of oxidation degrees of particular elements; knowledge of the composition, expressed by chemical formula of the species and its charge, is sufficient for this purpose. Approach I to GEB, known also as the "short" version of GEB, is applicable if oxidation degrees for all elements of the system are known beforehand. The roles of oxidants and reductants are not ascribed to particular components forming a system and to the species thus formed. This is the complete opposite of earlier approaches to redox titrations, based on the stoichiometric redox reaction, formulated for this purpose. GEB, perceived as a law of matter conservation, is fully compatible with other (charge and concentration) balances related to the system in question. The applicability of GATES/GEB in optimization a priori of chemical analyses made with use of redox titration is indicated. The article is illustrated with many examples of static and dynamic redox systems. The related plots are obtained from calculations made according to iterative computer programs. This way, GATES/GEB enables seeing details invisible in real experiments.

  2. Effectiveness and gastrointestinal tolerability during conversion and titration with once-daily OROS® hydromorphone extended release in opioid-tolerant patients with chronic low back pain

    PubMed Central

    Hale, Martin E; Nalamachu, Srinivas R; Khan, Arif; Kutch, Michael

    2013-01-01

    Purpose To describe the efficacy and safety of hydromorphone extended-release tablets (OROS hydromorphone ER) during dose conversion and titration. Patients and methods A total of 459 opioid-tolerant adults with chronic moderate to severe low back pain participated in an open-label, 2- to 4-week conversion/titration phase of a double-blind, placebo-controlled, randomized withdrawal trial, conducted at 70 centers in the United States. Patients were converted to once-daily OROS hydromorphone ER at 75% of the equianalgesic dose of their prior total daily opioid dose (5:1 conversion ratio), and titrated as frequently as every 3 days to a maximum dose of 64 mg/day. The primary outcome measure was change in pain intensity numeric rating scale; additional assessments included the Patient Global Assessment and the Roland–Morris Disability Questionnaire scores. Safety assessments were performed at each visit and consisted of recording and monitoring all adverse events (AEs) and serious AEs. Results Mean (standard deviation) final daily dose of OROS hydromorphone ER was 37.5 (17.8) mg. Mean (standard error of the mean [SEM]) numeric rating scale scores decreased from 6.6 (0.1) at screening to 4.3 (0.1) at the final titration visit (mean [SEM] change, −2.3 [0.1], representing a 34.8% reduction). Mean (SEM) change in Patient Global Assessment was −0.6 (0.1), and mean change (SEM) in the Roland–Morris Disability Questionnaire was −2.8 (0.3). Patients achieving a stable dose showed greater improvement than patients who discontinued during titration for each of these measures (P < 0.001). Almost 80% of patients achieving a stable dose (213/268) had a ≥30% reduction in pain. Commonly reported AEs were constipation (15.4%), nausea (11.9%), somnolence (8.7%), headache (7.8%), and vomiting (6.5%); 13.0% discontinued from the study due to AEs. Conclusion The majority of opioid-tolerant patients with chronic low back pain were successfully converted to effective doses of OROS hydromorphone ER within 2 to 4 weeks. PMID:23658495

  3. Native ESI Mass Spectrometry Can Help to Avoid Wrong Interpretations from Isothermal Titration Calorimetry in Difficult Situations

    NASA Astrophysics Data System (ADS)

    Wolff, Philippe; Da Veiga, Cyrielle; Ennifar, Eric; Bec, Guillaume; Guichard, Gilles; Burnouf, Dominique; Dumas, Philippe

    2017-02-01

    We studied by native ESI-MS the binding of various DNA-polymerase-derived peptides onto DNA-polymerase processivity rings from Escherichia coli, Pseudomonas aeruginosa, and Mycobacterium tuberculosis. These homodimeric rings present two equivalent specific binding sites, which leads to successive formation during a titration experiment of singly- and doubly occupied rings. By using the ESI-MS free-ring spectrum as a ruler, we derived by robust linear regression the fractions of the different ring species at each step of a titration experiment. These results led to accurate Kd values (from 0.03 to 0.5 μM) along with the probability of peptide loss due to gas phase dissociation (GPD). We show that this good quality is due to the increased information content of a titration experiment with a homodimer. Isothermal titration calorimetry (ITC) led with the same binding model to Kd(ITC) values systematically higher than their ESI-MS counterparts and, often, to poor fit of the ITC curves. A processing with two competing modes of binding on the same site requiring determination of two (Kd, ΔH) pairs greatly improved the fits and yielded a second Kd(ITC) close to Kd(ESI-MS). The striking features are: (1) ITC detected a minor binding mode ( 20%) of `low-affinity' that did not appear with ESI-MS; (2) the simplest processing of ITC data with only one (Kd, ΔH) pair led wrongly to the Kd of the low-affinity binding mode but to the ΔH of the high-affinity binding mode. Analogous misleading results might well exist in published data based on ITC experiments.

  4. A Geochemical Reaction Model for Titration of Contaminated Soil and Groundwater at the Oak Ridge Reservation

    NASA Astrophysics Data System (ADS)

    Zhang, F.; Parker, J. C.; Gu, B.; Luo, W.; Brooks, S. C.; Spalding, B. P.; Jardine, P. M.; Watson, D. B.

    2007-12-01

    This study investigates geochemical reactions during titration of contaminated soil and groundwater at the Oak Ridge Reservation in eastern Tennessee. The soils and groundwater exhibits low pH and high concentrations of aluminum, calcium, magnesium, manganese, various trace metals such as nickel and cobalt, and radionuclides such as uranium and technetium. The mobility of many of the contaminant species diminishes with increasing pH. However, base additions to increase pH are strongly buffered by various precipitation/dissolution and adsorption/desorption reactions. The ability to predict acid-base behavior and associated geochemical effects is thus critical to evaluate remediation performance of pH manipulation strategies. This study was undertaken to develop a practical but generally applicable geochemical model to predict aqueous and solid-phase speciation during soil and groundwater titration. To model titration in the presence of aquifer solids, an approach proposed by Spalding and Spalding (2001) was utilized, which treats aquifer solids as a polyprotic acid. Previous studies have shown that Fe and Al-oxyhydroxides strongly sorb dissolved Ni, U and Tc species. In this study, since the total Fe concentration is much smaller than that of Al, only ion exchange reactions associated with Al hydroxides are considered. An equilibrium reaction model that includes aqueous complexation, precipitation, ion exchange, and soil buffering reactions was developed and implemented in the code HydroGeoChem 5.0 (HGC5). Comparison of model results with experimental titration curves for contaminated groundwater alone and for soil- water systems indicated close agreement. This study is expected to facilitate field-scale modeling of geochemical processes under conditions with highly variable pH to develop practical methods to control contaminant mobility at geochemically complex sites.

  5. Equivalence-point electromigration acid-base titration via moving neutralization boundary electrophoresis.

    PubMed

    Yang, Qing; Fan, Liu-Yin; Huang, Shan-Sheng; Zhang, Wei; Cao, Cheng-Xi

    2011-04-01

    In this paper, we developed a novel method of acid-base titration, viz. the electromigration acid-base titration (EABT), via a moving neutralization boundary (MNR). With HCl and NaOH as the model strong acid and base, respectively, we conducted the experiments on the EABT via the method of moving neutralization boundary for the first time. The experiments revealed that (i) the concentration of agarose gel, the voltage used and the content of background electrolyte (KCl) had evident influence on the boundary movement; (ii) the movement length was a function of the running time under the constant acid and base concentrations; and (iii) there was a good linearity between the length and natural logarithmic concentration of HCl under the optimized conditions, and the linearity could be used to detect the concentration of acid. The experiments further manifested that (i) the RSD values of intra-day and inter-day runs were less than 1.59 and 3.76%, respectively, indicating similar precision and stability in capillary electrophoresis or HPLC; (ii) the indicators with different pK(a) values had no obvious effect on EABT, distinguishing strong influence on the judgment of equivalence-point titration in the classic one; and (iii) the constant equivalence-point titration always existed in the EABT, rather than the classic volumetric analysis. Additionally, the EABT could be put to good use for the determination of actual acid concentrations. The experimental results achieved herein showed a new general guidance for the development of classic volumetric analysis and element (e.g. nitrogen) content analysis in protein chemistry. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. An Open-label, Phase II Study of the Safety and Tolerability of Pirfenidone in Patients with Scleroderma-associated Interstitial Lung Disease: the LOTUSS Trial.

    PubMed

    Khanna, Dinesh; Albera, Carlo; Fischer, Aryeh; Khalidi, Nader; Raghu, Ganesh; Chung, Lorinda; Chen, Dan; Schiopu, Elena; Tagliaferri, Margit; Seibold, James R; Gorina, Eduard

    2016-09-01

    Systemic sclerosis-associated interstitial lung disease (SSc-ILD) shares a number of clinical features and pathogenic mechanisms with idiopathic pulmonary fibrosis (IPF). This study was designed to evaluate the tolerability of the IPF treatment pirfenidone in SSc-ILD. The known gastrointestinal, skin, and liver adverse events (AE) of pirfenidone are of importance given the involvement of these organs in SSc. All patients received pirfenidone and were randomized 1:1 to either a 2- or 4-week titration starting at 801 mg/day and finishing at a maintenance dose of 2403 mg/day. Patients received pirfenidone for 16 weeks in total. Assessments included treatment-emergent AE (TEAE) and exploratory disease outcomes. Sixty-three patients were randomized; 96.8% experienced a TEAE and more patients reported TEAE during the titration versus the maintenance period. The most commonly reported TEAE were consistent with those observed for pirfenidone in IPF (nausea, headache, fatigue) and were similar regardless of titration schedule. More patients discontinued treatment because of TEAE in the 2- versus 4-week titration group (5 vs 1, respectively); all discontinuation events occurred > 3 weeks after reaching the full dose of pirfenidone. Mycophenolate mofetil (MMF), taken by 63.5% of patients in addition to pirfenidone, did not appear to affect tolerability. Exploratory disease outcomes remained largely unchanged. Pirfenidone showed an acceptable tolerability profile in SSc-ILD, although a longer titration may be associated with better tolerability. Tolerability was not affected by concomitant MMF. The present findings support further investigation of pirfenidone in future clinical trials in patients with SSc-ILD. ClinicalTrials.gov; www.clinicaltrials.gov NCT01933334.

  7. Native ESI Mass Spectrometry Can Help to Avoid Wrong Interpretations from Isothermal Titration Calorimetry in Difficult Situations.

    PubMed

    Wolff, Philippe; Da Veiga, Cyrielle; Ennifar, Eric; Bec, Guillaume; Guichard, Gilles; Burnouf, Dominique; Dumas, Philippe

    2017-02-01

    We studied by native ESI-MS the binding of various DNA-polymerase-derived peptides onto DNA-polymerase processivity rings from Escherichia coli, Pseudomonas aeruginosa, and Mycobacterium tuberculosis. These homodimeric rings present two equivalent specific binding sites, which leads to successive formation during a titration experiment of singly- and doubly occupied rings. By using the ESI-MS free-ring spectrum as a ruler, we derived by robust linear regression the fractions of the different ring species at each step of a titration experiment. These results led to accurate K d values (from 0.03 to 0.5 μM) along with the probability of peptide loss due to gas phase dissociation (GPD). We show that this good quality is due to the increased information content of a titration experiment with a homodimer. Isothermal titration calorimetry (ITC) led with the same binding model to K d (ITC) values systematically higher than their ESI-MS counterparts and, often, to poor fit of the ITC curves. A processing with two competing modes of binding on the same site requiring determination of two (K d , ΔH) pairs greatly improved the fits and yielded a second K d (ITC) close to K d (ESI-MS). The striking features are: (1) ITC detected a minor binding mode (~20%) of 'low-affinity' that did not appear with ESI-MS; (2) the simplest processing of ITC data with only one (K d , ΔH) pair led wrongly to the Kd of the low-affinity binding mode but to the ΔH of the high-affinity binding mode. Analogous misleading results might well exist in published data based on ITC experiments. Graphical Abstract ᅟ.

  8. A high-throughput microtiter plate based method for the determination of peracetic acid and hydrogen peroxide.

    PubMed

    Putt, Karson S; Pugh, Randall B

    2013-01-01

    Peracetic acid is gaining usage in numerous industries who have found a myriad of uses for its antimicrobial activity. However, rapid high throughput quantitation methods for peracetic acid and hydrogen peroxide are lacking. Herein, we describe the development of a high-throughput microtiter plate based assay based upon the well known and trusted titration chemical reactions. The adaptation of these titration chemistries to rapid plate based absorbance methods for the sequential determination of hydrogen peroxide specifically and the total amount of peroxides present in solution are described. The results of these methods were compared to those of a standard titration and found to be in good agreement. Additionally, the utility of the developed method is demonstrated through the generation of degradation curves of both peracetic acid and hydrogen peroxide in a mixed solution.

  9. Galantamine-associated nightmares and anxiety.

    PubMed

    Corbo, Jason M; Brown, Jamie N; Moss, Jason M

    2013-04-01

    This case report describes recurrent nightmares and anxiety possibly caused by the administration and rapid dose titration of galantamine. A 90-year-old male with Alzheimer's disease was initiated on galantamine 4 mg twice daily for 10 days, followed by 8 mg twice daily thereafter. On followup to the geriatric clinic, the patient reported complaints of nightmares and associated anxiety. The occurrences of nightmares developed after initiating galantamine and temporally increased with galantamine titration. After discontinuation of galantamine, the patient reported no further occurrences of nightmares or anxiety and memory function remained stable. Galantamine-associated nightmares are an uncommon adverse event and may have been exacerbated by rapid titration. Although such adverse events are unlikely to cause harm in the patient, such sleep abnormalities have the potential to decrease a patient's quality of life and may require the need for alternative therapy.

  10. Kinetic Titration Series with Biolayer Interferometry

    PubMed Central

    Frenzel, Daniel; Willbold, Dieter

    2014-01-01

    Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1–42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations. PMID:25229647

  11. Kinetic titration series with biolayer interferometry.

    PubMed

    Frenzel, Daniel; Willbold, Dieter

    2014-01-01

    Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1-42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations.

  12. A High-Throughput Microtiter Plate Based Method for the Determination of Peracetic Acid and Hydrogen Peroxide

    PubMed Central

    Putt, Karson S.; Pugh, Randall B.

    2013-01-01

    Peracetic acid is gaining usage in numerous industries who have found a myriad of uses for its antimicrobial activity. However, rapid high throughput quantitation methods for peracetic acid and hydrogen peroxide are lacking. Herein, we describe the development of a high-throughput microtiter plate based assay based upon the well known and trusted titration chemical reactions. The adaptation of these titration chemistries to rapid plate based absorbance methods for the sequential determination of hydrogen peroxide specifically and the total amount of peroxides present in solution are described. The results of these methods were compared to those of a standard titration and found to be in good agreement. Additionally, the utility of the developed method is demonstrated through the generation of degradation curves of both peracetic acid and hydrogen peroxide in a mixed solution. PMID:24260173

  13. [The water content reference material of water saturated octanol].

    PubMed

    Wang, Haifeng; Ma, Kang; Zhang, Wei; Li, Zhanyuan

    2011-03-01

    The national standards of biofuels specify the technique specification and analytical methods. A water content certified reference material based on the water saturated octanol was developed in order to satisfy the needs of the instrument calibration and the methods validation, assure the accuracy and consistency of results in water content measurements of biofuels. Three analytical methods based on different theories were employed to certify the water content of the reference material, including Karl Fischer coulometric titration, Karl Fischer volumetric titration and quantitative nuclear magnetic resonance. The consistency of coulometric and volumetric titration was achieved through the improvement of methods. The accuracy of the certified result was improved by the introduction of the new method of quantitative nuclear magnetic resonance. Finally, the certified value of reference material is 4.76% with an expanded uncertainty of 0.09%.

  14. Kinetic titration with differential thermometric determination of the end-point.

    PubMed

    Sajó, I

    1968-06-01

    A method has been described for the determination of concentrations below 10(-4)M by applying catalytic reactions and using thermometric end-point determination. A reference solution, identical with the sample solution except for catalyst, is titrated with catalyst solution until the rates of reaction become the same, as shown by a null deflection on a galvanometer connected via bridge circuits to two opposed thermistors placed in the solutions.

  15. Processes for Assessing the Thermal Stability of Han-Based Liquid Propellants. Revision

    DTIC Science & Technology

    1990-07-01

    indicators is not adequate, and potentiometric determination cr’ the equivalence point is the most suitable method (Kraft and Fischer 1972). The use of...be determined by Karl Fischer titration. This method requires a special titration apparatus because the Titroprozessor 636 is not suited for this type... methods obtained from the literature (Kraft and Fischer 1972), and, where necessary, the manufacturer has modified evaluation methods (Firmenschrift

  16. Assembling and Using an LED-Based Detector to Monitor Absorbance Changes during Acid-Base Titrations

    ERIC Educational Resources Information Center

    Santos, Willy G.; Cavalheiro, E´der T. G.

    2015-01-01

    A simple photometric assembly based in an LED as a light source and a photodiode as a detector is proposed in order to follow the absorbance changes as a function of the titrant volume added during the course of acid-base titrations in the presence of a suitable visual indicator. The simplicity and low cost of the electronic device allow the…

  17. Endpoint titration and immunotherapy.

    PubMed

    King, H C

    1985-11-01

    Inhalant allergy, or "atopy" as it is now termed, is the best understood form of allergy today. In some circles, it is the only recognized form of allergy. While an overall picture of its effects on the body and a reasonable approach to its treatment now exist, many problems remain to be solved and much improvement in its treatment will probably occur within the next several years. Many new approaches to treatment of aeroallergens are now available; however, all are compared with the skin test, which is and has been the baseline for testing and treatment. Endpoint titration provides a quantitative means for undertaking treatment of aeroallergen sensitivity. In no other way does it differ from the forms of skin testing that have been widely used for generations. The practitioners of endpoint titration feel that this difference is highly significant in simplifying, validating, and shortening the necessary period of therapy. While the concept of endpoint titration is not difficult, it is by definition a quantitative form of testing and requires a degree of expertise in performing it correctly. While a good understanding of the method may be gained from the literature, adequate hands-on experience should be obtained by any physician prior to instituting the technique as a treatment modality. Once mastered, it becomes a reliable baseline for all forms of inhalant allergy care.

  18. Stabilization of the initial electrochemical potential for a metal-based potentiometric titration study of a biosorption process.

    PubMed

    Naja, Ghinwa; Mustin, Christian; Volesky, Bohumil; Berthelin, Jacques

    2006-01-01

    An interactive metal-based potentiometric titration method has been developed using an ion selective electrode for studying the sorption of metal cations. The accuracy of this technique was verified by analyzing the metal sorption mechanism for the biomass of Rhizopus arrhizus fungus and diatomite, two dissimilar materials (organic and mineral, strong sorbent and weak sorbent) of a different order of cation exchange capacity. The problem of the initial electrochemical potential was addressed identifying the usefulness of a Na-sulfonic resin as a strong chelating agent applied before the beginning of sorption titration experiments so that the titration curves and the sorption uptake could be quantitatively compared. The resin stabilized the initial electrochemical potential to -405+/-5 mV corresponding to 2 micro gl(-1) of lead concentration in solution. The amounts of lead sorbed by R. arrhizus biomass and diatomite were 0.9 mmol g(-1) (C(e)=5.16 x 10(-2)mM) and 0.052 mmol g(-1) (C(e)=5.97 x 10(-2) mM), respectively. Lead sorption by the fungal biomass was pinpointed to at least two types of chemical active sites. The first type was distinguished by high reactivity and a low number of sites whereas the other was characterized by their higher number and lower reactivity.

  19. Effect of surface site interactions on potentiometric titration of hematite (α-Fe2O3) crystal faces.

    PubMed

    Chatman, Shawn; Zarzycki, P; Preočanin, T; Rosso, K M

    2013-02-01

    Time dependent potentiometric pH titrations were used to study the effect of atomic scale surface structure on the protonation behavior of the structurally well-defined hematite/electrolyte interfaces. Our recently proposed thermodynamic model [1,25] was applied to measured acidimetric and alkalimetric titration hysteresis loops, collected from highly organized (001), (012), and (113) crystal face terminations using pH equilibration times ranging from 15 to 30 min. Hysteresis loop areas indicate that (001) faces equilibrate faster than the (012) and (113) faces, consistent with the different expected ensembles of singly-, doubly-, and triply-coordinated surface sites on each face. Strongly non-linear hysteretic pH-potential relationships were found, with slopes exceeding Nernstian, collectively indicating that protonation and deprotonation is much more complex than embodied in present day surface complexation models. The asymmetrical shape of the acidimetric and alkalimetric titration branches were used to illustrate a proposed steric "leaky screen" repulsion/trapping interaction mechanism that stems from high affinity singly-coordinated sites electrostatically and sterically screening lower affinity doubly- and triply-coordinated sites. Our data indicate that site interaction is the dominant phenomenon defining surface potential accumulation behavior on single crystal faces of metal oxide minerals. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Concentration-related response potentiometric titrations to study the interaction of small molecules with large biomolecules.

    PubMed

    Hamidi-Asl, Ezat; Daems, Devin; De Wael, Karolien; Van Camp, Guy; Nagels, Luc J

    2014-12-16

    In the present paper, the utility of a special potentiometric titration approach for recognition and calculation of biomolecule/small-molecule interactions is reported. This approach is fast, sensitive, reproducible, and inexpensive in comparison to the other methods for the determination of the association constant values (Ka) and the interaction energies (ΔG). The potentiometric titration measurement is based on the use of a classical polymeric membrane indicator electrode in a solution of the small-molecule ligand. The biomolecule is used as a titrant. The potential is measured versus a reference electrode and transformed into a concentration-related signal over the entire concentration interval, also at low concentrations, where the millivolt (y-axis) versus log canalyte (x-axis) potentiometric calibration curve is not linear. In the procedure, Ka is calculated for the interaction of cocaine with a cocaine binding aptamer and with an anticocaine antibody. To study the selectivity and cross-reactivity, other oligonucleotides and aptamers are tested, as well as other small ligand molecules such as tetrakis(4-chlorophenyl)borate, metergoline, lidocaine, and bromhexine. The calculated Ka compared favorably to the value reported in the literature using surface plasmon resonance. The potentiometric titration approach called "concentration-related response potentiometry" is used to study molecular interaction for seven macromolecular target molecules and four small-molecule ligands.

  1. Hydrogen ion titrations of the anodic and cathodic haemoglobin components of the European eel Anguilla anguilla.

    PubMed

    Brauner, C J; Weber, R E

    1998-09-01

    H+ titrations were conducted on the separated haemoglobin components of eel Anguilla anguilla in both the oxygenated and deoxygenated states. In anodic haemoglobin, the addition of GTP, and to a lesser extent C1-, increased the magnitude of the Haldane effect and shifted its maximum value into the in vivo pH range. Of the 22 histidine residues in the anodic component, only approximately seven were titratable, presumably the beta-chain residues at positions 41, 97, 109 and 146 (helical positions C7, FG4, G11 and HC3, respectively). In cathodic haemoglobin, a small negative Haldane effect was observed at pH values between 6.8 and 8.5 which disappeared in the presence of GTP (molar ratio 3:1 GTP:haemoglobin tetramer). GTP had virtually no effect on the buffer value at fixed oxygenation status, and the lowest buffer value was observed at in vivo pH values. No titratable histidine residues were observed in the cathodic component, indicating that all 14 histidines in this component are buried. We conclude that the anodic component, which constitutes two-thirds of the haemoglobin in the eel, plays the predominant role in CO2 transport and pH homeostasis in vivo.

  2. A rapid method for infectivity titration of Andes hantavirus using flow cytometry.

    PubMed

    Barriga, Gonzalo P; Martínez-Valdebenito, Constanza; Galeno, Héctor; Ferrés, Marcela; Lozach, Pierre-Yves; Tischler, Nicole D

    2013-11-01

    The focus assay is currently the most commonly used technique for hantavirus titer determination. This method requires an incubation time of between 5 and 11 days to allow the appearance of foci after several rounds of viral infection. The following work presents a rapid Andes virus (ANDV) titration assay, based on viral nucleocapsid protein (N) detection in infected cells by flow cytometry. To this end, an anti-N monoclonal antibody was used that was developed and characterized previously. ANDV N could be detected as early as 6 h post-infection, while viral release was not observed until 24-48 h post-infection. Given that ANDV detection was performed during its first round of infection, a time reduction for titer determination was possible and provided results in only two days. The viral titer was calculated from the percentage of N positive cells and agreed with focus assay titers. Furthermore, the assay was applied to quantify the inhibition of ANDV cell entry by patient sera and by preventing endosome acidification. This novel hantavirus titration assay is a highly quantitative and sensitive tool that facilitates infectivity titration of virus stocks, rapid screening for antiviral drugs, and may be further used to detect and quantify infectious virus in human samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Characterization of acid functional groups of carbon dots by nonlinear regression data fitting of potentiometric titration curves

    NASA Astrophysics Data System (ADS)

    Alves, Larissa A.; de Castro, Arthur H.; de Mendonça, Fernanda G.; de Mesquita, João P.

    2016-05-01

    The oxygenated functional groups present on the surface of carbon dots with an average size of 2.7 ± 0.5 nm were characterized by a variety of techniques. In particular, we discussed the fit data of potentiometric titration curves using a nonlinear regression method based on the Levenberg-Marquardt algorithm. The results obtained by statistical treatment of the titration curve data showed that the best fit was obtained considering the presence of five Brønsted-Lowry acids on the surface of the carbon dots with constant ionization characteristics of carboxylic acids, cyclic ester, phenolic and pyrone-like groups. The total number of oxygenated acid groups obtained was 5 mmol g-1, with approximately 65% (∼2.9 mmol g-1) originating from groups with pKa < 6. The methodology showed good reproducibility and stability with standard deviations below 5%. The nature of the groups was independent of small variations in experimental conditions, i.e. the mass of carbon dots titrated and initial concentration of HCl solution. Finally, we believe that the methodology used here, together with other characterization techniques, is a simple, fast and powerful tool to characterize the complex acid-base properties of these so interesting and intriguing nanoparticles.

  4. Developing a Physiotherapy-Specific Preliminary Clinical Decision-Making Tool for Oxygen Titration: A Modified Delphi Study

    PubMed Central

    Duong, Michelle; Bertin, Kendra; Henry, Renee; Singh, Deepti; Timmins, Nolla; Brooks, Dina; Mathur, Sunita

    2014-01-01

    ABSTRACT Purpose: To develop and evaluate a preliminary clinical decision-making tool (CDMT) to assist physiotherapists in titrating oxygen for acutely ill adults in Ontario. Methods: A panel of 14 experienced cardiorespiratory physiotherapists was recruited. Factors relating to oxygen titration were identified using a modified Delphi technique. Four rounds of questionnaires were conducted, during which the goals were to (1) generate factors, (2) reduce factors and debate contentious factors, (3) finalize factors and develop the preliminary CDMT, and (4) evaluate the usability of the tool in a clinical context. Results: The panel reached consensus on a total of 89 factors, which were compiled to create the preliminary CDMT. The global tool reached consensus for sensibility, receiving a mean score of 6/7 on a 7-point Likert-type scale (1=unacceptable; 7=excellent). Five of the nine individual components of evaluation of the tool achieved scores ≥6.0; the remaining four had mean scores between 5.4 and 5.9. Conclusion: This study produced a preliminary CDMT for oxygen titration, which the panel agreed was highly comprehensible and globally sensible. Further research is necessary to evaluate the sensibility and applicability of the tool in a clinical setting. PMID:25125782

  5. Comparison of Efficacy and Tolerance of Automatic Continuous Positive Airway Pressure Devices With the Optimum Continuous Positive Airway Pressure.

    PubMed

    Tommi, George; Aronow, Wilbert S; Sheehan, John C; McCleay, Matthew T; Meyers, Patrick G

    Patients diagnosed with obstructive sleep apnea syndrome were randomly placed on automatic continuous positive airway pressure (ACPAP) for 2 hours followed by manual titration for the rest of the night. One hundred sixty-one patients entered the study, with at least 50 patients titrated with each of 3 ACPAP devices. The optimum continuous positive airway pressure (CPAP) was defined as the lowest pressure with an apnea-hypoxia index of ≤5/hr, which ranged from 4 cm to 18 cm. Success with ACPAP was approximately 60%-80% when the optimum CPAP was 4-6 cm but fell to below 30% if the optimum CPAP was ≥8 cm (P = 0.001). Average ACPAP ranged from 2 to 10 cm below the optimum level if the optimum CPAP was ≥8 cm. Patients who responded to a low CPAP but deteriorated on higher pressures failed to respond to any of the automatic devices. We recommend that CPAP titration be performed manually before initiation of ACPAP in patients with obstructive sleep apnea. The basal pressure for ACPAP should be the optimum pressure obtained by manual titration. Limits on the upper level of ACPAP may be necessary for patients who deteriorate on higher positive pressures.

  6. Calculations of proton-binding thermodynamics in proteins.

    PubMed

    Beroza, P; Case, D A

    1998-01-01

    Computational models of proton binding can range from the chemically complex and statistically simple (as in the quantum calculations) to the chemically simple and statistically complex. Much progress has been made in the multiple-site titration problem. Calculations have improved with the inclusion of more flexibility in regard to both the geometry of the proton binding and the larger scale protein motions associated with titration. This article concentrated on the principles of current calculations, but did not attempt to survey their quantitative performance. This is (1) because such comparisons are given in the cited papers and (2) because continued developments in understanding conformational flexibility and interaction energies will be needed to develop robust methods with strong predictive power. Nevertheless, the advances achieved over the past few years should not be underestimated: serious calculations of protonation behavior and its coupling to conformational change can now be confidently pursued against a backdrop of increasing understanding of the strengths and limitations of such models. It is hoped that such theoretical advances will also spur renewed experimental interest in measuring both overall titration curves and individual pKa values or pKa shifts. Exploration of the shapes of individual titration curves (as measured by Hill coefficients and other parameters) would also be useful in assessing the accuracy of computations and in drawing connections to functional behavior.

  7. Misoprostol versus antacid titration for preventing stress ulcers in postoperative surgical ICU patients.

    PubMed Central

    Zinner, M J; Rypins, E B; Martin, L R; Jonasson, O; Hoover, E L; Swab, E A; Fakouhi, T D

    1989-01-01

    Bleeding from gastroduodenal lesions is a potentially life-threatening complication in patients subjected to overwhelming physiologic stress. Titration of gastric contents with antacid was the first prophylactic treatment regimen proved to decrease the incidence of bleeding and remains the standard by which other methods are compared. We designed a prospective double-blind, double-placebo study comparing the effectiveness of antacid titration with fixed doses of a synthetic prostaglandin E1 analog (misoprostol) for preventing stress gastritis and bleeding. To assess the success of each treatment regimen, we did endoscopic examinations before operation, 72 hours after operation, and after the patient had completed the study. A total of 281 patients entered the study (140 misoprostol, 141 antacid). The two groups were comparable with respect to preoperative parameters and type of operation. We found no statistically significant differences between the two treatment groups concerning upper gastrointestinal tract lesions or serious adverse effects. No clinically evident upper gastrointestinal hemorrhage occurred in either group. Mean gastric pH, measured at two-hour intervals during the initial 72 hours, was maintained at 4.0 or higher in both groups. We conclude that fixed-dose misoprostol is as effective as intensive antacid titration in preventing stress ulcers and bleeding in surgical ICU patients. PMID:2510618

  8. Change in frequency of periodic limb movements during sleep with usage of continuous positive airway pressure in obstructive sleep apnea syndrome.

    PubMed

    Aritake-Okada, Sayaka; Namba, Kazuyoshi; Hidano, Natsuki; Asaoka, Shoichi; Komada, Yoko; Usui, Akira; Matsuura, Masato; Inoue, Yuichi

    2012-06-15

    Periodic limb movements during sleep (PLMS) sometimes newly appear on the night of continuous positive airway pressure (CPAP) titration in patients with obstructive sleep apnea syndrome (OSAS). To ascertain the incidence and causative factors of this phenomenon, we investigated differences in its prevalence and the factors associated with newly appeared and persistent PLMS on CPAP titration night. We retrospectively analyzed polysomnographic data of 997 consecutive OSAS outpatients who had undergone overnight CPAP titration. On the basis of changes in periodic limb movements index (PLMI) values (cut off level≥15/h) from baseline polysomnography (BPSG) to CPAP titration PSG, patients were assigned to one of four groups: persistent, CPAP-emergent, CPAP-disappeared, and non-PLMS. The rate of patients was 6.7% in the persistent group, 8.0% in the CPAP-emergent group, 4.0% in the CPAP-disappearance group, and 81.2% in the non-PLMS group. Multivariate logistic regression analysis revealed that a higher apnea-hypopnea index (AHI) on BPSG and ≥47years of age appeared to be associated with the CPAP-emergent group. The results suggest that elderly patients with higher AHI at BPSG may present with CPAP-emergent PLMS. Copyright © 2012. Published by Elsevier B.V.

  9. Calorimetry, activity, and micro-FTIR analysis of CO chemisorption, titration, and oxidation on supported Pt

    NASA Technical Reports Server (NTRS)

    Sermon, Paul A.; Self, Valerie A.; Vong, Mariana S. W.; Wurie, Alpha T.

    1990-01-01

    The value of in situ analysis on CO chemisorption, titration and oxidation over supported Pt catalysts using calorimetry, catalytic and micro-FTIR methods is illustrated using silica- and titania-supported samples. Isothermal CO-O and O2-CO titrations have not been widely used on metal surfaces and may be complicated if some oxide supports are reduced by CO titrant. However, they can illuminate the kinetics of CO oxidation on metal/oxide catalysts since during such titrations all O and CO coverages are scanned as a function of time. There are clear advantages in following the rates of the catalyzed CO oxidation via calorimetry and gc-ms simultaneously. At lower temperatures the evidence they provide is complementary. CO oxidation and its catalysis of CO oxidation have been extensively studied with hysteresis and oscillations apparent, and the present results suggest the benefits of a combined approach. Silica support porosity may be important in defining activity-temperature hysteresis. FTIR microspectroscopy reveals the chemical heterogeneity of the catalytic surfaces used; it is interesting that the evidence with regard to the dominant CO surface species and their reactivities with regard to surface oxygen for present oxide-supported Pt are different from those seen on graphite-supported Pt.

  10. Normal Hematological, Biochemical, and Serum Electrolyte Values for a Colony of Rhesus Monkeys ’Macaca mulatta’,

    DTIC Science & Technology

    1976-10-28

    ammonia quantitatively with alpha - ketoglutarate along with the oxidation of NADH to NAD. The resultant decrease in absorbence at 340 nm is directly...Sephrophore III membranes. 3. Serum Electrolytes a. Calcium - A manual fluorescent titration method was used to determine serum calcium concentration...The dye calcein fluoresces in the presence of calcium . This fluorescent complex is titrated with ethylenediamine tetra-acetic acid (EDTA), the end

  11. Comparison of ozone determinations by ultraviolet photometry and gas-phase titration

    NASA Technical Reports Server (NTRS)

    Demore, W. B.; Patapoff, M.

    1976-01-01

    A comparison of ozone determinations based on ultraviolet absorption photometry and gas-phase titration (GPT) shows good agreement between the two methods. Together with other results, these findings indicate that three candidate reference methods for ozone, UV photometry, IR photometry, and GPT are in substantial agreement. However, the GPT method is not recommended for routine use by air pollution agencies for calibration of ozone monitors because of susceptibility to experimental error.

  12. Atomic and Molecular Gas Phase Spectrometry.

    DTIC Science & Technology

    1983-09-30

    between the thermometric levels, k is the Boltzmann constant (k = 0.695 cm-I K-1 ), Aik (s- 1) is the transition probability for spontaneous emission from...monitoring of the atomic absorption of M; information about the reaction processes were deduced from the shapes of the titration curves; (5) measure- ment of...Changes During Titration Based Upon The Releasing Effect Atomic Absorption Spectroscopy," D. Stojanovic and J.D. Winefordner, Anal Chim. Acta, 114, 295

  13. Towed Thermistor Chain Observations in Fronts-80,

    DTIC Science & Technology

    1980-10-01

    thermistors were manu- factured by Thermometrics (Model P-85) and had a time constant of about 0.1 s (D. Caldwell, personal communication). The thermistors were...salinometer and occasionally by titration . A time series of salinity determined by the three aforementioned methods appears in Figure 8. Some of the...obviously erroneous values have been removed. The difference between salinity from the CTD and from the salinometer and titration is shown in Figure 9

  14. Potentiometric titration of thiols, cationic surfactants and halides using a solid-state silver-silver sulphide electrode.

    PubMed

    Pinzauti, S; Papeschi, G; La Porta, E

    1983-01-01

    A rugged, low resistance silver-silver sulphide solid-state electrode for determining pharmaceuticals as authentic samples or in dosage forms by potentiometric titration is described. Sodium tetraphenylborate, mercury(II) acetate and silver nitrate (0.01) M were employed as titrants in the analysis of cationic surfactants (cetylpyridinium chloride, benzethonium chloride, benzalkonium chloride and chlorhexidine salts), antithyroid drugs (methimazole and propylthiouracil) or sodium halides respectively.

  15. Army Oil Analysis Program for Vehicle Testing

    DTIC Science & Technology

    1996-08-16

    4 TOP 2-2-690 16 August 1996 (l) Water determination: Karl Fischer method (TM 38-301-2 or ASTM-D1744 3 ): Set up the Karl Fischer titrator in...higher temperature if required. aMagnification. bReflected. CTransmitted. 5. DATA REQUIRED. a. Water: Karl Fischer percent water-- (% H2 0). b...Liquid Petroleum Products by Karl Fischer Reagent, 1984. 4. DL 18, Karl Fischer Titrator Operating Instructions. 5. ASTM-D445, Annual Book of ASTM

  16. Analysis of Aircraft Fuels and Related Materials

    DTIC Science & Technology

    1982-09-01

    content by the Karl Fischer method . Each 2040 solvent sample represented a different step in a clean-up procedure conducted by Aero Propulsion...izes a potentiometric titration with alcoholic silver nitrate. This method has a minimum detectability of 1 ppm. It has a re- peatability of 0.1 ppm... Method 163-80, which util- izes a potentiometric titration with alcoholic silver nitrate. This method has a minimum detectability of 1 ppm and has a

  17. High-throughput Titration of Luciferase-expressing Recombinant Viruses

    PubMed Central

    Garcia, Vanessa; Krishnan, Ramya; Davis, Colin; Batenchuk, Cory; Le Boeuf, Fabrice; Abdelbary, Hesham; Diallo, Jean-Simon

    2014-01-01

    Standard plaque assays to determine infectious viral titers can be time consuming, are not amenable to a high volume of samples, and cannot be done with viruses that do not form plaques. As an alternative to plaque assays, we have developed a high-throughput titration method that allows for the simultaneous titration of a high volume of samples in a single day. This approach involves infection of the samples with a Firefly luciferase tagged virus, transfer of the infected samples onto an appropriate permissive cell line, subsequent addition of luciferin, reading of plates in order to obtain luminescence readings, and finally the conversion from luminescence to viral titers. The assessment of cytotoxicity using a metabolic viability dye can be easily incorporated in the workflow in parallel and provide valuable information in the context of a drug screen. This technique provides a reliable, high-throughput method to determine viral titers as an alternative to a standard plaque assay. PMID:25285536

  18. The binding of aluminum to mugineic acid and related compounds as studied by potentiometric titration.

    PubMed

    Yoshimura, Etsuro; Kohdr, Hicham; Mori, Satoshi; Hider, Robert C

    2011-08-01

    The phytosiderophores, mugineic acid (MA) and epi-hydroxymugineic acid (HMA), together with a related compound, nicotianamine (NA), were investigated for their ability to bind Al(III). Potentiometric titration analysis demonstrated that MA and HMA bind Al(III), in contrast to NA which does not under normal physiological conditions. With MA and HMA, in addition to the Al complex (AlL), the protonated (AlLH) and deprotonated (AlLH(-1)) complexes were identified from an analysis of titration curves, where L denotes the phytosiderophore form in which all the carboxylate functions are ionized. The equilibrium formation constants of the Al(III) phytosiderophore complexes are much smaller than those of the corresponding Fe(III) complexes. The higher selectivity of phytosiderophores for Fe(III) over Al(III) facilitates Fe(III) acquisition in alkaline conditions where free Al(III) levels are higher than free Fe(III) levels.

  19. Determination of pKa values of new phenacyl-piperidine derivatives by potentiometric titration method in aqueous medium at room temperature (25±0.5oC).

    PubMed

    Zafar, Shaista; Akhtar, Shamim; Tariq, Talat; Mushtaq, Noushin; Akram, Arfa; Ahmed, Ahsaan; Arif, Muhammad; Naeem, Sabahat; Anwar, Sana

    2014-07-01

    Dissociation constant (pKa) of ten novel phenacyl derivatives of piperidine were determined by potentiometric titration method in aqueous medium at room temperature (25 ±0.5°C). The sample solutions were prepared in deionized water with ionic strength 0.01M and titrated with 0.1M NaOH solution. In addition, ΔG values were also calculated. Different prediction software programs were used to calculate pKa values too and compared to the experimentally observed pKa values. The experimental and theoretical values were found in close agreement. The results obtained in this research would help to predict the good absorption of the studied compounds and can be selected as lead molecules for the synthesis of CNS active agents because of their lipophilic nature especially compound VII.

  20. Comparison of HPLC, UV spectrophotometry and potentiometric titration methods for the determination of lumefantrine in pharmaceutical products.

    PubMed

    da Costa César, Isabela; Nogueira, Fernando Henrique Andrade; Pianetti, Gérson Antônio

    2008-09-10

    This paper describes the development and evaluation of a HPLC, UV spectrophotometry and potentiometric titration methods to quantify lumefantrine in raw materials and tablets. HPLC analyses were carried out using a Symmetry C(18) column and a mobile phase composed of methanol and 0.05% trifluoroacetic acid (80:20), with a flow rate of 1.0ml/min and UV detection at 335nm. For the spectrophotometric analyses, methanol was used as solvent and the wavelength of 335nm was selected for the detection. Non-aqueous titration of lumefantrine was carried out using perchloric acid as titrant and glacial acetic acid/acetic anhydride as solvent. The end point was potentiometrically determined. The three evaluated methods showed to be adequate to quantify lumefantrine in raw materials, while HPLC and UV methods presented the most reliable results for the analyses of tablets.

  1. Expert Comment: Is Medication Titration in Heart Failure too Complex?

    PubMed Central

    Hickey, Annabel

    2017-01-01

    Abstract Large-scale randomised controlled trials (RCTs) have demonstrated that angiotensin-converting enzyme inhibitors, angiotensin receptor blockers and beta-blockers decrease mortality and hospitalisation in patients with heart failure (HF) associated with a reduced left ventricular ejection fraction. This has led to high prescription rates; however, these drugs are generally prescribed at much lower doses than the doses achieved in the RCTs. A number of strategies have been evaluated to improve medication titration in HF, including forced medication up-titration protocols, point-of-care decision support and extended scope of clinical practice for nurses and pharmacists. Most successful strategies have been multifaceted and have adapted existing multidisciplinary models of care. Furthermore, given the central role of general practitioners in long-term monitoring and care coordination in HF patients, these strategies should engage with primary care to facilitate the transition between the acute and primary healthcare sectors. PMID:28785472

  2. Combination of Continuous Dexmedetomidine Infusion with Titrated Ultra-Low-Dose Propofol-Fentanyl for an Awake Craniotomy

    PubMed Central

    Das, Samaresh; Al-Mashani, Ali; Suri, Neelam; Salhotra, Neeraj; Chatterjee, Nilay

    2016-01-01

    An awake craniotomy is a continuously evolving technique used for the resection of brain tumours from the eloquent cortex. We report a 29-year-old male patient who presented to the Khoula Hospital, Muscat, Oman, in 2016 with a two month history of headaches and convulsions due to a space-occupying brain lesion in close proximity with the left motor cortex. An awake craniotomy was conducted using a scalp block, continuous dexmedetomidine infusion and a titrated ultra-low-dose of propofolfentanyl. The patient remained comfortable throughout the procedure and the intraoperative neuropsychological tests, brain mapping and tumour resection were successful. This case report suggests that dexmedetomidine in combination with titrated ultra-low-dose propofolfentanyl are effective options during an awake craniotomy, ensuring optimum sedation, minimal disinhibition and a rapid recovery. To the best of the authors’ knowledge, this is the first awake craniotomy conducted successfully in Oman. PMID:27606116

  3. A comparison of cationic polymerization and esterification for end-point detection in the catalytic thermometric titration of organic bases.

    PubMed

    J Greenhow, E; Viñas, P

    1984-08-01

    A systematic comparison has been made of two indicator systems for the non-aqueous catalytic thermometric titration of strong and weak organic bases. The indicator reagents, alpha-methylstyrene and mixtures of acetic anhydride and hydroxy compounds, are shown to give results (for 14 representative bases) which do not diner significantly in coefficient of variation or titration error. Calibration graphs for all the samples, in the range 0.01-0.1 meq, are linear, with correlation coefficients of 0.995 or better. Aniline, benzylamine, n-butylamine, morpholine, pyrrole, l-dopa, alpha-methyl-l-dopa, dl-alpha-alanine, dl-leucine and l-cysteine cannot be determined when acetic anhydride is present in the sample solution, but some primary and second amines can. This is explained in terms of rates of acetylation of the amino groups.

  4. [Intragastric utilization of antacids following meals in relation to stomach emptying].

    PubMed

    Lux, G; Hartog, C; Ruppin, H; Lederer, P; Schmitt, W

    1983-03-01

    Gastric acid secretion and gastric emptying rate was measured using double marker method and continuous titration of a liquid peptone test meal. Titration rate was significantly reduced by 30 ml of an aluminiumhydroxide- and magnesiumhydroxide containing antacid compound (Maalox). Acidity of gastric contents was reduced over a period of 48.4 +/- 9.1 min (mean +/- SD; endpoint of titration pH 5.5) and 77.6 +/- 2.0 min (pH 3.5) (p less than 0.05). The histamine H2-receptor blocker Ranitidine (0.25 mg/kg b.w.) and the antimuscarinic agent Pirenzepine reduced titrable gastric acid secretion in a similar range, as far as the observation period of 90 min is concerned. Biosorbin MCT, a formula diet, stimulated gastric acid secretion half the amount of gastric acid secretion stimulated by the peptone meal. Gastric emptying rate was significantly reduced by formula diet, but not by either of the other compounds.

  5. Antioxidative Categorization of Twenty Amino Acids Based on Experimental Evaluation.

    PubMed

    Xu, Naijin; Chen, Guanqun; Liu, Hui

    2017-11-27

    In view of the great importance bestowed on amino acids as antioxidants in oxidation resistance, we attempted two common redox titration methods in this report, including micro-potassium permanganate titration and iodometric titration, to measure the antioxidative capacity of 20 amino acids, which are the construction units of proteins in living organisms. Based on the relative intensities of the antioxidative capacity, we further conducted a quantitative comparison and found out that the product of experimental values obtained from the two methods was proven to be a better indicator for evaluating the relative antioxidative capacity of amino acids. The experimental results were largely in accordance with structural analysis made on amino acids. On the whole, the 20 amino acids concerned could be divided into two categories according to their antioxidative capacity. Seven amino acids, including tryptophan, methionine, histidine, lysine, cysteine, arginine and tyrosine, were greater in total antioxidative capacity compared with the other 13 amino acids.

  6. Humic substance charge determination by titration with a flexible cationic polyelectrolyte

    NASA Astrophysics Data System (ADS)

    Tan, Wen-Feng; Norde, Willem; Koopal, Luuk K.

    2011-10-01

    The anionic charge of humic substances (HS) plays a major role in the interaction of HS with other components. Therefore, the potential of the polyelectrolyte titration technique to obtain the charge density of HS in simple 1-1 electrolyte solutions has been investigated. Titrations are carried out with an automatic titrator combined with the "Mütek particle charge detector" which allows determination of the Mütek potential and the pH as a function of the added amount of titrant which is a solution of poly-diallyldimethylammonium chloride (polyDADMAC), a cationic strong polyelectrolyte. When the Mütek potential reverses its sign the iso-electric point (IEP) of the polyDADMAC-HS complex is reached. The polyDADMAC/HS mass ratio at the IEP gives information on the HS charge density and from the pH changes in solution an estimate of the charge regulation in the HS-polyDADMAC complex can be obtained. In general, for polyDADMAC-HS complexes an increase in the dissociation of the acid groups of HS is found (charge regulation). The charge regulation decreases with increasing concentration of 1-1 background electrolyte. Cation incorporation can be neglected at 1-1 electrolyte concentrations ⩽ 1 mmol L -1 and a 1-1 stoichiometry exists between the polyDADMAC and HS charge. However, at these low salt concentrations the charge regulation is substantial. A detailed analysis of purified Aldrich humic acid (PAHA) at pH 5 and a range of KCl concentrations reveals that the anionic charge of PAHA in the complex increases at 5 mmol L -1 KCl by 30% and at 150 mmol L -1 KCl by 12%. On the other hand, increasing amounts of K + become incorporated in the complex: at 5 mmol L -1 KCl 5% and at 150 mmol L -1 KCl 24% of the PAHA charge is balanced by K +. By comparing at pH 5 the mass ratios polyDADMAC/PAHA in the complex at the IEP with the theoretical mass ratios of polyDADMAC/PAHA required to neutralize PAHA in the absence of charge regulation and K + incorporation, it is found that at 50 mmol L -1 KCl the extra negative charge due to the interaction between polyDADMAC and PAHA is just compensated by K + incorporation in the complex. Therefore, a pseudo 1-1 stoichiometry exists at about 50 mmol L -1 1-1 electrolyte concentration and only at this salt concentration polyDADMAC titrations and conventional proton titrations give identical results. Most likely this is also true for other HA samples and other pH values. For FA further study is required to reveal the conditions for which polyDADMAC and proton titrations give identical results.

  7. Development of Conductivity Method as an Alternative to Titration for Hydrolytic Resistance Testing Used for Evaluation of Glass Vials Used in Pharmaceutical Industry.

    PubMed

    Fujimori, Kiyoshi; Lee, Hans; Phillips, Joseph; Nashed-Samuel, Yasser

    The European Pharmacopeia surface test to analyze the hydrolytic resistance is a common industrial method to understand and ensure the quality of produced glass vials. Hydrolytic resistance is evaluated by calculating the alkalinity of water extract from autoclaved vials by titration. As an alternative to this titration technique, a conductivity technique was assessed, which directly measures the ions in the water extract. A conductivity meter with a 12 mm diameter electrode was calibrated with a 100 μS/cm conductivity standard and carryover minimized by rinsing the probe in a water beaker per analysis. The limit of quantification at 1 μS/cm was determined as having a signal-to-noise ratio of 3 compared with the water blank. The conductivity method was selective for glass-composing elements (boron, sodium, aluminum, silicon, potassium, and calcium) within the vial extract. Accuracies of spiked conductivity standard within the range of 1 to 100 μS/cm were ±7% and had linearity with coefficient of determination (R 2 ) of ≥0.9999. Intraday precision had a relative standard deviation (RSD) (n = 5) of ≤6% for spiked conductivity standard within the range of 1 to 100 μS/cm. Interday precision had a RSD (n = 4) of ≤6% for 10 vials from three glass vial lots. Conductivity of water extracts from nine sets of seven lots of glass vials had a precise linear relationship [R 2 = 0.9876, RSD = 1% (n = 9)] with titration volumes of the same lots. Conductivity results in μS/cm could be converted to titration volumes in milliliters by a conversion factor of 0.0275. The simplicity, sample stability, and individual vial analysis of the conductivity technique were more advantageous than the current titration technique. The quality of glass vials used as primary containers in the pharmaceutical industry is of concern due to recent observations of glass flake-like delamination, or lamellae, under specific storage conditions. The current European Pharmacopoeia method to assess glass vial quality utilizes acid titration of vial extract pools to determine hydrolytic resistance or alkalinity. As an alternative to the European Pharmacopoeia method, the vial extracts were analyzed for conductivity, which directly determines the level of ions that were readily extracted from the vial surfaces. Lower quality glass would have greater surface defects that lead to higher ions extracted and higher conductivity value. The conductivity method was found to be suitable to measure the ions in water extracts and showed strong correlation with alkalinity. The advantage of the conductivity method over the alkalinity method was greater ease, lower volume requirements, stability, and flexibility in analysis. © PDA, Inc. 2017.

  8. Semi-empirical proton binding constants for natural organic matter

    NASA Astrophysics Data System (ADS)

    Matynia, Anthony; Lenoir, Thomas; Causse, Benjamin; Spadini, Lorenzo; Jacquet, Thierry; Manceau, Alain

    2010-03-01

    Average proton binding constants ( KH,i) for structure models of humic (HA) and fulvic (FA) acids were estimated semi-empirically by breaking down the macromolecules into reactive structural units (RSUs), and calculating KH,i values of the RSUs using linear free energy relationships (LFER) of Hammett. Predicted log KH,COOH and log KH,Ph-OH are 3.73 ± 0.13 and 9.83 ± 0.23 for HA, and 3.80 ± 0.20 and 9.87 ± 0.31 for FA. The predicted constants for phenolic-type sites (Ph-OH) are generally higher than those derived from potentiometric titrations, but the difference may not be significant in view of the considerable uncertainty of the acidity constants determined from acid-base measurements at high pH. The predicted constants for carboxylic-type sites agree well with titration data analyzed with Model VI (4.10 ± 0.16 for HA, 3.20 ± 0.13 for FA; Tipping, 1998), the Impermeable Sphere model (3.50-4.50 for HA; Avena et al., 1999), and the Stockholm Humic Model (4.10 ± 0.20 for HA, 3.50 ± 0.40 for FA; Gustafsson, 2001), but differ by about one log unit from those obtained by Milne et al. (2001) with the NICA-Donnan model (3.09 ± 0.51 for HA, 2.65 ± 0.43 for FA), and used to derive recommended generic values. To clarify this ambiguity, 10 high-quality titration data from Milne et al. (2001) were re-analyzed with the new predicted equilibrium constants. The data are described equally well with the previous and new sets of values ( R2 ⩾ 0.98), not necessarily because the NICA-Donnan model is overparametrized, but because titration lacks the sensitivity needed to quantify the full binding properties of humic substances. Correlations between NICA-Donnan parameters are discussed, but general progress is impeded by the unknown number of independent parameters that can be varied during regression of a model fit to titration data. The high consistency between predicted and experimental KH,COOH values, excluding those of Milne et al. (2001), gives faith in the proposed semi-empirical structural approach, and its usefulness to assess the plausibility of proton stability constants derived from simulations of titration data.

  9. Efficacy and tolerability of combination therapy with valsartan/hydrochlorothiazide in the initial treatment of severe hypertension.

    PubMed

    Calhoun, David A; Glazer, Robert D; Pettyjohn, Frank S; Coenen, P D M; Zhao, Yanxing; Grosso, Amie

    2008-08-01

    Most patients with severe hypertension are at high risk for cardiovascular events and require prompt blood pressure (BP)-lowering and combination therapy to achieve BP goals. This study evaluated the therapeutic efficacy and tolerability of initial treatment with the combination of valsartan and hydrochlorothiazide (HCTZ) compared with valsartan monotherapy in patients with severe hypertension. This was a 6-week, randomized, double-blind, multicenter, forced titration study that compared initial therapy with the combination of valsartan/HCTZ 160/12.5 mg (force titrated to 160/25 mg after 2 weeks and to 320/25 mg after 4 weeks) to monotherapy with valsartan 160 mg (force titrated to 320 mg after 2 weeks and sham-titrated to 320 mg after 4 weeks). Eligible patients were 18-80 years old with severe essential hypertension (mean sitting diastolic BP > or = 110 mmHg and < 120 mmHg and mean sitting systolic BP > or = 140 mmHg and < 200 mmHg). The Clinical Trial Registry number was NCT00273299. The primary efficacy variable was the rate of BP control (mean sitting BP < 140/90 mmHg) at Week 4. Tolerability was evaluated by monitoring all adverse events, vital signs, and laboratory tests including hematology and biochemistry. A total of 608 patients were randomized to either valsartan/HCTZ (n = 307) or valsartan monotherapy (n = 301). Significantly more patients achieved overall BP control (< 140/90 mmHg) with valsartan/HCTZ compared to monotherapy at Week 4 (primary efficacy variable and timepoint) (39.6% vs. 21.8%; p < 0.0001) and Week 6 (48.2% vs. 27.2%; p < 0.0001). Mean reductions in BP at Week 4 were significantly greater for valsartan/HCTZ (30.8/22.7 mmHg vs. 21.7/17.5 mmHg; p < 0.0001), with further reductions at Week 6. BP control rates were greater with combination therapy as early as Week 2. The overall incidence of adverse events was comparable between the combination therapy (34.9%) and monotherapy (36.7%) treatment groups. A potential limitation of the forced-titration design is that some patients were titrated to higher doses despite having achieved goal BP. This may impact the interpretation of the incidence of dose-dependent adverse events. Initial therapy with valsartan/HCTZ is effective and well tolerated in patients with severe hypertension.

  10. Investigation of the use of thermometric titrimetry for the determination of acidic substances in wine.

    PubMed

    Godinho, O E; Coelho, J A; Chagas, A P; Aleixo, L M

    1984-03-01

    The use of thermometric titrimetry in the determination of acidic substances in red wine is described. The titration curve obtained in the thermometric titration of red wine with strong base presents two inflections. The stoichiometry corresponding to the first inflection presents good agreement with the so-called "total acidity" of wine, and is proposed for its determination. The second inflection is related to the content of phenolic substances in red wine.

  11. Potentiometric/turbidometric titration of antiperspirant actives.

    PubMed

    Johnston, Clifford T; Hem, Stanley L; Guenin, Eric; Mattai, Jairajh; Afflito, John

    2003-01-01

    A titration procedure that simultaneously monitors the pH and turbidity of an antiperspirant solution during neutralization with sodium hydroxide was developed to characterize antiperspirant actives. Aluminum chloride, aluminum chlorohydrate (ACH), and aluminum zirconium glycine complex (AZG) gave distinctive pH/turbidity profiles. The activated forms of aluminum chlorohydrate (ACH') and aluminum zirconium glycine complex (AZG') produced more turbidity than the non-activated forms. On an equimolar basis, AZG' produced more turbidity than any of the antiperspirant actives tested.

  12. A wet chemical method for the estimation of carbon in uranium carbides.

    PubMed

    Chandramouli, V; Yadav, R B; Rao, P R

    1987-09-01

    A wet chemical method for the estimation of carbon in uranium carbides has been developed, based on oxidation with a saturated solution of sodium dichromate in 9M sulphuric acid, absorption of the evolved carbon dioxide in a known excess of barium hydroxide solution, and titration of the excess of barium hydroxide with standard potassium hydrogen phthalate solution. The carbon content obtained is in good agreement with that obtained by combustion and titration.

  13. Best Technical Approach for the Petroleum Quality Analysis (PQA) System

    DTIC Science & Technology

    1994-08-01

    two test methods for determination of water content in a fuel. The Karl Fischer titration method (ASTM D 1744) measures for total water, both...difficult to automate. ASTM D 664, "Standard Test Method for Acid Number of Petroleum Products by Potentiometric Titration," is simple to automate...release. distribution unlimnied 13. ABSTRACT (Maximum 2C3 words) Recent U.S. militar-y operations have identified a need for improved methods of fuel and

  14. Effect of cholesterol on the interaction of the amphibian antimicrobial peptide DD K with liposomes.

    PubMed

    Verly, Rodrigo M; Rodrigues, Magali A; Daghastanli, Katia Regina P; Denadai, Angelo Márcio L; Cuccovia, Iolanda M; Bloch, Carlos; Frézard, Frédéric; Santoro, Marcelo M; Piló-Veloso, Dorila; Bemquerer, Marcelo P

    2008-01-01

    DD K is an antimicrobial peptide previously isolated from the skin of the amphibian Phyllomedusa distincta. The effect of cholesterol on synthetic DD K binding to egg lecithin liposomes was investigated by intrinsic fluorescence of tryptophan residue, measurements of kinetics of 5(6)-carboxyfluorescein (CF) leakage, dynamic light scattering and isothermal titration microcalorimetry. An 8 nm blue shift of tryptophan maximum emission fluorescence was observed when DD K was in the presence of lecithin liposomes compared to the value observed for liposomes containing 43 mol% cholesterol. The rate and the extent of CF release were also significantly reduced by the presence of cholesterol. Dynamic light scattering showed that lecithin liposome size increase from 115 to 140 nm when titrated with DD K but addition of cholesterol reduces the liposome size increments. Isothermal titration microcalorimetry studies showed that DD K binding both to liposomes containing cholesterol as to liposomes devoid of it is more entropically than enthalpically favored. Nevertheless, the peptide concentration necessary to furnish an adjustable titration curve is much higher for liposomes containing cholesterol at 43 mol% (2 mmol L(-1)) than in its absence (93 micromol L(-1)). Apparent binding constant values were 2160 and 10,000 L mol(-1), respectively. The whole data indicate that DD K binding to phosphatidylcholine liposomes is significantly affected by cholesterol, which contributes to explain the low hemolytic activity of the peptide.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, Guoping; Luo, Wensui; Brooks, Scott C

    We conducted batch and recirculating column titration tests with contaminated acidic sediments with controlled CO2 in the headspace, and extended the geochemical model by Gu et al. (2003, GCA) to better understand and quantify the reactions governing trace metal fate in the subsurface. The sediment titration curve showed slow pH increase due to strong buffering by Al precipitation and CO2 uptake. Assuming precipitation of basaluminite at low saturation index (SI=-4), and decreasing cation exchange selectivity coefficient (kNa\\Al=0.3), the predictions are close to the observed pH and Al; and the model explains 1) the observed Ca, Mg, and Mn concentration decreasemore » by cation exchange with sorbed Al, and 2) the decrease of U by surface complexation with Fe hydroxides at low pH, and precipitation as liebigite (Ca2UO2(CO3)3:10H2O) at pH>5.5. Without further adjustment geochemical parameters, the model describes reasonably well previous sediment and column titration tests without CO2 in the headspace, as well as the new large column test. The apparent inhibition of U and Ni decrease in the large column can be explained by formation of aqueous carbonate complexes and/or competition with carbonate for surface sites. These results indicated that ignoring labile solid phase Al would underestimate base requirement in titration of acidic aquifers.« less

  16. Labour induction at term--a randomised trial comparing Foley catheter plus titrated oral misoprostol solution, titrated oral misoprostol solution alone, and dinoprostone.

    PubMed

    Matonhodze, Baron B; Hofmeyr, G Justus; Levin, Jonathan

    2003-05-01

    To compare three methods of labour induction. Randomised controlled trial. Academic hospitals in Johannesburg, South Africa. Women with intact membranes due for induction of labour. Randomised, sealed opaque envelopes were used to allocate women to labour induction with extra-amniotic Foley catheter/titrated oral misoprostol solution (N = 174), titrated oral misoprostol solution alone (N = 176), or vaginal dinoprostone (N = 176). Misoprostol was dissolved in water and 20-40 g was given 2-hourly. These were failure to deliver vaginally within 24 hours, additional measures for induction or augmentation of labour, analgesia, and maternal and fetal complications. In the Foley catheter group, misoprostol was required in all but 1 case. Failure to deliver vaginally within 24 hours was similar for the three groups (79/174 v. 70/176 v. 70/176 respectively). Labour augmentation, caesarean section and instrumental delivery were used somewhat more frequently in the Foley/misoprostol group than in the misoprostol alone group, but these differences were not statistically significant. More analgesia was used in the Foley catheter/misoprostol group than in the misoprostol group (64/172 v. 46/175). Side-effects and neonatal complications were similar for the three groups. Use of extra-amniotic Foley catheter placement showed no measurable benefits over the use of oral misoprostol alone, or vaginal dinoprostone.

  17. Efficient analysis of stochastic gene dynamics in the non-adiabatic regime using piecewise deterministic Markov processes

    PubMed Central

    2018-01-01

    Single-cell experiments show that gene expression is stochastic and bursty, a feature that can emerge from slow switching between promoter states with different activities. In addition to slow chromatin and/or DNA looping dynamics, one source of long-lived promoter states is the slow binding and unbinding kinetics of transcription factors to promoters, i.e. the non-adiabatic binding regime. Here, we introduce a simple analytical framework, known as a piecewise deterministic Markov process (PDMP), that accurately describes the stochastic dynamics of gene expression in the non-adiabatic regime. We illustrate the utility of the PDMP on a non-trivial dynamical system by analysing the properties of a titration-based oscillator in the non-adiabatic limit. We first show how to transform the underlying chemical master equation into a PDMP where the slow transitions between promoter states are stochastic, but whose rates depend upon the faster deterministic dynamics of the transcription factors regulated by these promoters. We show that the PDMP accurately describes the observed periods of stochastic cycles in activator and repressor-based titration oscillators. We then generalize our PDMP analysis to more complicated versions of titration-based oscillators to explain how multiple binding sites lengthen the period and improve coherence. Last, we show how noise-induced oscillation previously observed in a titration-based oscillator arises from non-adiabatic and discrete binding events at the promoter site. PMID:29386401

  18. Transitional polytherapy: tricks of the trade for monotherapy to monotherapy AED conversions.

    PubMed

    Garnett, William R; St Louis, Erik K; Henry, Thomas R; Bramley, Thomas

    2009-06-01

    The goal of epilepsy therapy is to help patients achieve seizure freedom without adverse effects. While monotherapy is preferable in epilepsy treatment, many patients fail a first drug due to lack of efficacy or failure to tolerate an initial medication, necessitating an alteration in therapy. Sudden changes between monotherapies are rarely feasible and sometimes deleterious given potential hazards of acute seizure exacerbation or intolerable adverse effects. The preferred method for converting between monotherapies is transitional polytherapy, a process involving initiation of a new antiepileptic drug (AED) and adjusting it toward a target dose while maintaining or reducing the dose of the baseline medication. A fixed-dose titration strategy of maintaining the baseline drug dose while titrating the new medication is preferable when breakthrough seizures are occurring and no adverse effects are present. However, a flexible titration strategy involving reduction of the baseline drug dose to ensure adequate tolerability of the new adjunctive medication is preferred when patients are already experiencing adverse effects. This article reviews pharmacokinetic considerations pertinent for ensuring successful transitional polytherapy with the standard and newer antiepileptic drugs. Practical consensus recommendations "from an expect panel (SPECTRA, Study by a Panel of Experts Considerations for Therapy Replacement and Antiepileptics) for a successful monotherapy" AED conversions are then summarized. Transitional polytherapy is most successful when clinicians appropriately manage the titration strategy and consider pharmacokinetic factors germane to the baseline and new adjunctive medication.

  19. Fermentation of aqueous plant seed extracts by lactic acid bacteria

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schafner, D.W.; Beuchat, R.L.

    1986-05-01

    The effects of lactic acid bacterial fermentation on chemical and physical changes in aqueous extracts of cowpea (Vigna unguiculata), peanut (Arachis hypogea), soybean (Glycine max), and sorghum (Sorghum vulgare) were studied. The bacteria investigated were Lactobacillus helveticus, L. delbrueckii, L. casei, L. bulgaricus, L. acidophilus, and Streptococcus thermophilus. Organisms were inoculated individually into all of the seed extracts; L. bulgaricus and S. thermophilus were also evaluated together as inocula for fermenting the legume extracts. During fermentation, bacterial population and changes in titratable acidity, pH, viscosity, and color were measured over a 72 h period at 37 degrees C. Maximum bacterialmore » populations, titratable acidity, pH, and viscosity varied depending upon the type of extract and bacterial strain. The maximum population of each organism was influenced by fermentable carbohydrates, which, in turn, influenced acid production and change in pH. Change in viscosity was correlated with the amount of protein and titratable acidity of products. Color was affected by pasteurization treatment and fermentation as well as the source of extract. In the extracts inoculated simultaneously with L. bulgaricus and S. thermophilus, a synergistic effect resulted in increased bacterial populations, titratable acidity, and viscosity, and decreased pH in all the legume extracts when compared to the extracts fermented with either of these organisms individually. Fermented extracts offer potential as substitutes for cultured dairy products. 24 references.« less

  20. Total Acid Value Titration of Hydrotreated Biomass Fast Pyrolysis Oil: Determination of Carboxylic Acids and Phenolics with Multiple End-Point Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christensen, E.; Alleman, T. L.; McCormick, R. L.

    Total acid value titration has long been used to estimate corrosive potential of petroleum crude oil and fuel oil products. The method commonly used for this measurement, ASTM D664, utilizes KOH in isopropanol as the titrant with potentiometric end point determination by pH sensing electrode and Ag/AgCl reference electrode with LiCl electrolyte. A natural application of the D664 method is titration of pyrolysis-derived bio-oil, which is a candidate for refinery upgrading to produce drop in fuels. Determining the total acid value of pyrolysis derived bio-oil has proven challenging and not necessarily amenable to the methodology employed for petroleum products duemore » to the different nature of acids present. We presented an acid value titration for bio-oil products in our previous publication which also utilizes potentiometry using tetrabutylammonium hydroxide in place of KOH as the titrant and tetraethylammonium bromide in place of LiCl as the reference electrolyte to improve the detection of these types of acids. This method was shown to detect numerous end points in samples of bio-oil that were not detected by D664. These end points were attributed to carboxylic acids and phenolics based on the results of HPLC and GC-MS studies. Additional work has led to refinement of the method and it has been established that both carboxylic acids and phenolics can be determined accurately. Use of pH buffer calibration to determine half-neutralization potentials of acids in conjunction with the analysis of model compounds has allowed us to conclude that this titration method is suitable for the determination of total acid value of pyrolysis oil and can be used to differentiate and quantify weak acid species. The measurement of phenolics in bio-oil is subject to a relatively high limit of detection, which may limit the utility of titrimetric methodology for characterizing the acidic potential of pyrolysis oil and products.« less

Top