Lee, Ho Min; Kim, Jong Pil; Chung, Phil Hyun; Kang, Suk; Kim, Young Sung; Go, Bo Seong
2018-05-24
Knee dislocation following total knee replacement arthroplasty is a rare but serious complication. The incidence of dislocation following primary total knee arthroplasty with posterior stabilized implants ranges from 0.15 to 0.5%, and posterior dislocation after revision total knee arthroplasty is even rarer. Here, we report the case of a 76-year-old male who presented with posterior dislocation after posterior stabilized revision total knee arthroplasty.
Sisak, Krisztian; Lloyd, John; Fiddian, Nick
2011-01-01
Peripheral nerve blocks have found increased popularity in providing prolonged post-operative analgesia following total knee replacement surgery. They generally provide effective analgesia with fewer complications than epidurals. This report describes an acute low-energy knee dislocation after a well balanced, fixed bearing, cruciate-retaining primary total knee replacement performed under a spinal anaesthetic with combined complimentary femoral and sciatic nerve blocks. The dislocation was not accompanied by neurovascular compromise. Due to the subsequent instability and injury to both collaterals, the posterior cruciate ligament and posterolateral corner structures, the knee was treated with a rotating-hinge revision total knee replacement. The dislocation occurred whilst the peripheral nerve blocks (PNB) were still working. We review our incidence of PNB related complications and conclude that PNB remain a safe and effective analgesia for total knee replacements. However, we advocate that ward staff and patients should be sufficiently educated to ensure that unaided post-operative mobilisation is prevented until such a time that patients have regained complete voluntary muscle control. Copyright © 2009 Elsevier B.V. All rights reserved.
Harb, Z; Harb, A; Kammoona, Ishan; Huber, C
2011-04-01
In lower extremity trauma, it is routine to check the neurovascular status of the affected limb. Failure to recognise a vascular injury can have catastrophic consequences for the patient. The frequent observation of the distal pulses at regular intervals after a traumatic knee dislocation is absolutely mandatory for the early recognition and management of popliteal artery thrombosis. A limb-threatening complication of popliteal artery thrombosis occurring in association with a palpable dorsalis pedis pulse after a trampoline-related knee dislocation is reported here to emphasise some important teaching points. These lessons are a learning tool to help in the early recognition of the potential complications associated with such injuries and thus minimise their occurrence.
Samson, Deepak; Ng, Chye Yew; Power, Dominic
2016-01-01
Traumatic knee dislocation is a complex ligamentous injury that may be associated with simultaneous vascular and neurological injury. Although orthopaedic surgeons may consider CPN exploration at the time of ligament reconstruction, there is no standardised approach to the management of this complex and debilitating complication. This review focusses on published evidence of the outcomes of common peroneal nerve (CPN) injuries associated with knee dislocation, and proposes an algorithm for the management. Cite this article: Deepak Samson, Chye Yew Ng, Dominic Power. An evidence-based algorithm for the management of common peroneal nerve injury associated with traumatic knee dislocation. EFORT Open Rev 2016;1:362-367. DOI: 10.1302/2058-5241.160012. PMID:28461914
[Joint dislocation after total knee arthroplasty as an ankle fracture complication. Case report].
Hrubina, M; Skoták, M
2012-01-01
Joint dislocation after total knee arthroplasty is a rare complication. It is described as the result of ligamentous instability. Here we report the case of an 82-year-old women who underwent primary total knee arthroplasty (TKA) for advanced primary grade III gonarthrosis. At 3 post-operative months the joint was stable and painless, with radiographic evidence of good TKA alignment and integration. At 4 months the patient suffered injury to the ankle involving a bimalleolar fracture and damage to knee soft tissues. The fracture was surgically treated. Subsequently, dorsal tibial dislocation was manifested. This was managed by individual intramedullary nail arthrodesis. At 8 months following the operation, the knee condition was satisfactory, with rigid arthrodesis and leg shortening of 4 cm. The patient was satisfied because she was free of pain and able to walk. Arthrodesis of the knee joint with an individual nail is an option for a definitive treatment of TKA instability. When other joints, such as ankle or hip joints, are injured, it is recommended to pay attention also to any TKA implanted previously because of potential development of instability or infection.
Bakalakos, Matthaios; Benetos, Ioannis S; Rozis, Meletios; Vlamis, John; Pneumaticos, Spiros
2018-06-02
The majority of injuries during a football game are contusions, sprains and/or strains in the thigh, knee and ankle. Hip dislocations account for 2-5% of total hip dislocations, and they can be posterior or anterior. Major complications of traumatic hip dislocation include avascular necrosis of femoral head, secondary osteoarthritis, sciatic nerve injury and heterotopic ossification. On the occasion of a case of a 33-year-old football player, who suffered a posterior hip dislocation, associated with a posterior wall fracture of the acetabulum, while playing football, we review the literature and analyze the various mechanisms of injury, the possible complications and the management including surgery and rehabilitation.
Miranda, Fernando E; Dennis, James W; Veldenz, Henry C; Dovgan, Peter S; Frykberg, Eric R
2002-02-01
Knee dislocation, which poses a significant risk for injury of the popliteal artery, prompts many surgeons to evaluate these patients with arteriography routinely. Our hypothesis was that physical examination alone (without arteriography) accurately confirms or excludes surgically significant vascular injuries associated with knee dislocation. All patients diagnosed with a knee dislocation by an attending orthopedic surgeon between January 1990 and January 2000 were prospectively managed by protocol at our Level I trauma center according to their physical examination. Those with hard signs (active hemorrhage, expanding hematoma, absent pulse, distal ischemia, bruit/thrill) underwent arteriography followed immediately by surgical repair if indicated. Patients with no hard signs (negative physical examination) were admitted for 23 hours, underwent serial physical examination, and then followed as outpatients. There were 35 knee dislocations in 35 patients during this 10-year period. The average age was 31 years; 18 dislocations were on the right knee and 17 were on the left. Two patients died from closed head injuries and multisystem trauma. Eight patients were found to have hard signs (positive physical examination) either at presentation (six patients) or during their hospitalization after reduction of their dislocation (two patients). All eight patients demonstrated a loss of pulses only. Six of these patients showed occlusion of the popliteal artery on arteriography and underwent surgical repair without complication (five vein grafts, one primary repair), one demonstrated spasm of the popliteal artery, and one showed a normal artery that required no treatment. None of the 27 patients with negative physical examination during their hospitalization ever developed limb ischemia, needed an operation for vascular injury, or experienced limb loss. Sixteen patients were available for follow-up (46%). Twelve patients with negative physical examination (44%) were contacted (mean, 13 months; range, 2-35 months), and four of the eight patients with positive physical examination (50%) and surgical repair were contacted (mean, 19 months; range, 6-49 months). None of the patients in either group developed any vascular-related symptoms or suffered from a vascular repair complication over the follow-up interval. This limited series suggests that the presence or absence of an injury of the popliteal artery after knee dislocation can be safely and reliably predicted, with a 94.3% positive predictive value and 100% negative predictive value. Arteriography appears to be unnecessary when physical examination is negative but may avert negative vascular exploration when physical examination is positive. This approach substantially reduces cost and resource use without adverse impact on the patient.
[Atraumatic dislocation in mobile-bearing total knee arthroplasty: two case reports].
Schuh, A; Hönle, W
2007-10-01
Atraumatic dislocation following total knee arthroplasty (TKA) is a rare condition. Severe complications after dislocation are lesion of the vascular-nerve bundle, compartment syndrome or amputation. The benefit of TKA with mobile-bearing are an improvement of the range of motion and better articulation. In comparison to fixed-bearing TKA there is the risk of dislocation or breakage of the polyethylene insert. We present two cases with dislocation following TKA with mobile-bearing. In both cases preoperatively there was a significant weakening of the function of the quadriceps muscle. During revision of the TKA severe damage with multiple scratches of the polyethylene onlay could be detected. The damage of the PE onlay could especially be found at the tibial aspect. Follow-up showed an uneventful course after conversion to fixed-bearing polyethylen component. In cases of dislocation following TKA with mobile-bearing operative revision is recommended to exchange the damaged PE onlay and prevent increased wear. TKA with mobile-bearing should be reserved only for cases with a good quadriceps muscle function.
... dwarfism might have: cleft palate hand and ear differences hip dysplasia club feet severe curvature of the spine early deterioration of joints and joint stiffness potential hip and knee dislocation Complications From Spondyloepiphyseal Dysplasia ...
Demographics and Injuries Associated With Knee Dislocation: A Prospective Review of 303 Patients
Moatshe, Gilbert; Dornan, Grant J.; Løken, Sverre; Ludvigsen, Tom C.; LaPrade, Robert F.; Engebretsen, Lars
2017-01-01
Background: Information on the incidence, injury mechanisms, ligament injury patterns, and associated injuries of knee dislocations is lacking in the literature. There is a need to characterize ligament injury patterns and associated injuries in knee dislocations to avoid missing common associated diagnoses and to plan surgical treatment. Purpose: To evaluate patient demographics, ligament injury patterns and associated injury patterns, and associated injuries in patients with knee dislocation. Study Design: Cross-sectional study; Level of evidence, 3. Methods: A total of 303 patients with knee dislocations treated at a single level 1 trauma center were followed prospectively. Injury mechanism; ligament injury patterns; associated neurovascular, meniscal, and cartilage injuries; and surgical complications were recorded. The Schenck knee dislocation classification was used to classify the ligament injury patterns. Results: The mean age at injury was 37.8 ± 15.3 years. Of the 303 patients included, 65% were male and 35% were female. There was an equal distribution of high-energy and low-energy injuries. Injury to 3 major ligaments was the most common, with Schenck classification type KD III-M constituting 52.4% of the injuries and KD III-L comprising 28.1%. Meniscal injuries and cartilage injuries occurred in 37.3% and 28.3% of patients, respectively. Patients with acute injuries had significantly lower odds of a cartilage injury than those with chronic injuries (odds ratio [OR], 0.28; 95% CI, 0.15-0.50; P < .001). Peroneal nerve injuries were recorded in 19.2% of patients (10.9% partial and 8.3% complete deficit), while vascular injuries were recorded in 5%. The odds of having a common peroneal nerve injury were 42 times greater (P < .001) among those with posterolateral corner injury (KD III-L) than those without. The odds for popliteal artery injury were 9 times greater (P = .001) among those with KD III-L injuries than other ligament injury types. Conclusion: Medial-sided bicruciate injuries were the most common injury pattern in knee dislocations. Cartilage injuries were common in chronically treated patients. There was a significant risk of peroneal nerve injury with lateral-sided injuries. PMID:28589159
Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao
2017-01-01
Abstract The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation. Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups. The mean follow-up time was 18.6 months (range: 5–24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5–9 months) and 6.0 months (range: 5–8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°–150°) and 135° (range: 100°–160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05). External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation. PMID:29019890
Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao
2017-10-01
The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation.Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups.The mean follow-up time was 18.6 months (range: 5-24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5-9 months) and 6.0 months (range: 5-8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°-150°) and 135° (range: 100°-160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05).External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation.
Ro, Kyung-Han; Heo, Jae-Won; Lee, Dae-Hee
2018-05-01
Implant survivorship is reported to be lower and complications, particularly bearing dislocation, are reported to be more frequent in Asian than in Western patients with medial knee osteoarthritis (OA) undergoing Oxford® Phase III unicompartmental knee arthroplasty (UKA). To date, however, these complications have not been compared between these groups of patients. The purpose of this study was to perform a meta-analysis comparing the standardized incidence rates of (1) all-cause reoperation; (2) reoperation related to bearing dislocation; and (3) reoperation related to progression of lateral compartment arthritis in Asian and Western patients with medial knee OA who underwent Oxford Phase III UKA. We searched MEDLINE® (January 1, 1976, to May 31, 2017), EMBASE® (January 1, 1985, to May 31, 2017), and the Cochrane Library (January 1, 1987, to May 31, 2017) for studies that reported complications of Oxford Phase III UKAs. Studies were included if they reported reoperation rates attributable to bearing dislocation and/or progression of lateral knee OA after surgery with this implant. Twenty-seven studies were included in this systematic review and 16 studies with followups > 5 years were included in the meta-analysis. These rates were converted to standardized incidence rate (that is, reoperations per 100 observed component years) based on mean followup and number of involved knees in each study. After applying prespecified inclusion and exclusion criteria, the studies were categorized into two groups, Asian and Western, based on hospital location. Twenty-five studies, containing 3152 Asian patients and 5455 Western patients, were evaluated. Study quality was assessed by the modified Coleman Methodology score (MCMS). Although all studies were Level IV, their mean MCMS score was 66.92 (SD, 8.7; 95% confidence interval [CI], 63.5-70.3), indicating fair quality. Because the heterogeneity of all subgroup meta-analyses was high, a random-effects model was used with estimations using the restricted maximum likelihood method. There was no difference in the proportion of Asian patients versus Western patients undergoing reoperation for any cause calculated as 100 component observed years (1.022 of 3152 Asian patients; 95% CI, 0.810-1.235 versus 1.300 of 5455 Western patients; 95% CI, 1.067-1.534; odds ratio, 0.7839; 95% CI, 0.5323-1.1545; p = 0.178). The mean reoperation rate attributable to bearing dislocation per 100 observed years was higher in Asian than in Western patients (0.525; 95% CI, 0.407-0.643 versus 0.141; 95% CI, 0.116-0.166; odds ratio, 3.7378; 95% CI, 1.694-8.248; p = 0.001) Conversely, the mean reoperation rate attributable to lateral knee OA per 100 observed years was lower in Asian than in Western patients (0.093; 95% CI, 0.070-0.115 versus 0.298; 95% CI, 0.217-0.379; odds ratio, 0.3114; 95% CI, 0.0986-0.9840; p < 0.001). Although total reoperation rates did not differ in the two populations, reoperation for bearing dislocation was more likely to occur in Asian than in Western patients, whereas reoperation for lateral knee OA progression was more likely to occur in Western than in Asian patients after Oxford Phase III UKA. Although possible explanations for these findings may be hypothesized, additional randomized, prospective comparative studies are needed. However, better survival outcomes after UKA may require consideration of ethnicity and lifestyle choices in addition to traditional surgical technique and perioperative care. Level III, therapeutic study.
Midterm Clinical and Radiographic Results of Mobile-Bearing Revision Total Knee Arthroplasty.
Kim, Raymond H; Martin, J Ryan; Dennis, Douglas A; Yang, Charlie C; Jennings, Jason M; Lee, Gwo-Chin
2017-06-01
Constrained implants are frequently required in revision total knee arthroplasty (TKA) and are associated with an increase in aseptic component loosening and damage or wear to the constraining mechanisms, compared with primary TKA. The purpose of the following study was to evaluate the midterm clinical and radiographic results including the incidence of bearing complications in a group of patients undergoing revision TKA using mobile-bearing revision TKA implants. We retrospectively reviewed 316 consecutive mobile-bearing revision TKAs performed at 2 centers between 2006 and 2010. There were 183 women and 133 men with a mean age of 66 years. The patients were evaluated clinically using the Knee Society scores. A radiographic analysis was performed. Bearing specific complications (ie, instability or dislocation) were recorded. Patients were followed-up for a minimum of 24 months and a median of 59.88 months (range 24-121.2). The average Knee Society knee score and function scores increased from 40.8 and 47.9 points preoperatively to 80 points and 70.3 points, respectively (P < .01). The average knee flexion improved from 105.6° preoperatively to 117.4° postoperatively (P < .01). Eight patients required subsequent implant revision. No cases of bearing complications were observed. Revision TKA using mobile-bearing revision components demonstrated favorable midterm clinical and radiographic results with no occurrence of bearing instability or dislocation. Longer follow-up is required to evaluate for potential advantages of mobile-bearings over fixed-bearing revision components in terms of polyethylene wear reduction, reduced stress transmission across fixation interfaces, and reduced stress on the polyethylene post. Copyright © 2017 Elsevier Inc. All rights reserved.
Ipsilateral hip and knee dislocation: Case report and review of literature
Sharma, Gaurav; Chahar, Deepak; Sreenivasan, Ravi; Verma, Nikhil; Pankaj, Amite
2016-01-01
Hip and knee dislocations are not uncommon but simultaneous ipsilateral dislocation of the hip and knee joint is rare; consequently, there is an inadequate amount of literature on the subject. We identified only 11 such cases reported in English literature. In the present report, we describe the case of a 23-year-old male patient who presented with ipsilateral hip and knee dislocation on the right side after being involved in a road traffic accident. The hip dislocation was associated with a posterior wall acetabular fracture. The hip as well as the knee joints was reduced in the emergency bay. The patient underwent an urgent fixation of the posterior wall acetabular fracture with delayed ligament reconstruction for the knee dislocation. At one-year follow-up, he had no pain in the hip or knee. There was grade 1 posterior sag but no symptoms of knee instability. Radiographs revealed no evidence of avascular necrosis or arthritis of the femoral head. The normal treatment protocol for individual injury is affected by the simultaneous occurrence of hip and knee dislocation. PMID:27182149
Patterson, Brendan M; Agel, Julie; Swiontkowski, Marc F; Mackenzie, Ellen J; Bosse, Michael J
2007-10-01
The purpose of this study is to report the clinical and functional results of a cohort of patients with knee dislocations associated with vascular injury. Patients with knee dislocation and associated vascular injury were prospectively assessed for outcome of severe lower extremity trauma during 2 years. The Sickness Impact Profile was used to assess the functional recovery of the patient. Surgeon and therapist assessments documented clinical metrics and treatment, including salvage or amputation, neurologic recovery, knee stability, and knee motion. Eighteen patients sustained a knee dislocation and an associated popliteal artery injury. Seven patients were found to have an additional vascular injury. All patients underwent repair of the vascular injury. At the time of final follow-up, 14 knees were successfully salvaged and four required amputation (1 below knee amputation, 2 through knee amputation, and 1 above knee amputation). Eighteen patients had at least a popliteal injury and underwent repair of the vascular injury. The patients with a limb-threatening knee dislocation that was successfully reconstructed had Sickness Impact Profile scores of 20.12 at 3 months, 13.18 at 6 months, 12.08 at 1 year, and 7.0 at 2 years after injury. Patients who sustain a limb-threatening knee dislocation have a moderate to high level of disability 2 years after injury. Nearly one in five patients who present to a Level I trauma center with a dysvascular limb associated with a knee dislocation will require amputation. Prolonged warm ischemia time was associated with a high rate of amputation. Patients who sustain vascular injuries associated with a knee dislocation need immediate transport to a trauma hospital, rapid assessment and diagnosis at presentation, and revascularization. Patients with these injuries can be effectively treated without angiography before surgery.
Kodkani, Pranjal S
2016-01-01
Background: Bone tunneling and implants with rigid fixations for medial patellofemoral ligament (MPFL) reconstruction are known to compromise results and are avoidable, especially in skeletally immature subjects. This study was to assess if these deficiencies were overcome with the technique devised by the author which avoids implants and bone tunnels. Results were assessed for complication rate and outcome. Materials and Methods: Fifty six knees of recurrent lateral patellar dislocation were treated in the past 49 months by MPFL reconstruction. Thirty nine were female and 17 male knees. The mean age was 20.6 years (range 9-48 years). Mean followup was 26 months. Five knees had previously failed stabilization procedures. Thirty one cases had Dejours Type A or B and 12 had Type C trochlear dysplasia. Arthroscopy was performed for associated injuries and loose bodies. Seven knees required loose body removal. Five knees underwent lateral retinacular release. Four knees had tibial tuberosity transfer. One knee had an associated anterior cruciate ligament reconstruction. An anatomical MPFL reconstruction was performed using hamstring autograft without the need for intraoperative fluoroscopy. Only soft tissue fixation was necessary with this newly devised technique and suturing. A rapid rehabilitation protocol was implemented with monthly followup until normalcy and 6 monthly thereafter. Results: All achieved full range of motion and normal mediolateral stability. There was no recurrence of dislocation. No major surgery related complications. One patella fracture at 8 months was due to a fall developed terminal restriction of flexion. Those in sports could return to their sporting activities (Tegner 1–9). Cases with osteochondral fractures had occasional pain that subsided in 1 year. Mean Kujala score improved from 64.3 to 99.69 with KOOS score near normal in all. Conclusion: This new method of MPFL reconstruction gives excellent results. It avoids complications related to bone tunneling and implants. It is a safe, effective, reliable and reproducible technique. PMID:26952121
Habitual dislocation of patella: A review
Batra, Sumit; Arora, Sumit
2014-01-01
Habitual dislocation of patella is a condition where the patella dislocates whenever the knee is flexed and spontaneously relocates with extension of the knee. It is also termed as obligatory dislocation as the patella dislocates completely with each flexion and extension cycle of the knee and the patient has no control over the patella dislocating as he or she moves the knee1. It usually presents after the child starts to walk, and is often well tolerated in children, if it is not painful. However it may present in childhood with dysfunction and instability. Very little literature is available on habitual dislocation of patella as most of the studies have combined cases of recurrent dislocation with habitual dislocation. Many different surgical techniques have been described in the literature for the treatment of habitual dislocation of patella. No single procedure is fully effective in the surgical treatment of habitual dislocation of patella and a combination of procedures is recommended. PMID:25983506
... dislocates to the outside of the knee Knee pain and tenderness Knee swelling "Sloppy" kneecap -- you can move the kneecap ... knee and you notice: Increased instability in your knee Pain or swelling return after they went away Your ...
Non-Traumatic Anterior Dislocation of a Total Knee Replacement Associated with Neurovascular Injury
Aderinto, Joseph; Gross, Allan E; Rittenhouse, Bryan
2009-01-01
Prosthetic total knee replacements rarely dislocate. When dislocation does occur, it is usually in a posterior direction in association with a posterior stabilised, cruciate-sacrificing prosthesis. Neurovascular injury is unusual. In this report, we describe a case of anterior dislocation of a cruciate-retaining total knee replacement in a 67-year-old woman. The dislocation occurred in the absence of overt trauma and resulted in severe neurovascular injury. PMID:19686618
[ANALYSIS OF IMPLANT-RELATED COMPLICATIONS AFTER HINGE KNEE REPLACEMENT FOR TUMORS AROUND THE KNEE].
Li, Dong; Ma, Huanzhi; Zhang, Wei; Sun, Chengliang; Lu, Xiaoyong; Gao, Yutong; Zhou, Dongsheng
2015-08-01
To investigate the reasons and managements of implant-related complications after hinge knee replacement for tumors around the knee. A retrospective analysis was made on the clinical data of 96 patients undergoing hinge knee replacement between January 2000 and December 2012. There were 64 males and 32 females with the mean age of 31.0 years (range, 15-72 years). The most common tumor type was osteosarcoma (72 cases), and the second was giant cell tumor (15 cases). The tumor located at the distal femurs in 52 cases and at the proximal tibias in 44 cases. Fifteen hinge and 81 rotating hinge prostheses were used. The recurrence, metastasis, and survival were recorded. The implant-related complications were observed. The median follow-up time was 43.5 months (range, 10-156 months). Complications were observed in 21 patients (25 implant-related complications); 13 complications located at the femur and 12 complications at the tibia. The complications included aseptic loosening (8 cases), deep infection (7 cases), prosthetic breakage (4 cases), peri-prosthetic fracture (2 cases), and dislocation (4 cases). Most deep infection occurred within 12 months after operation (6/7), and most aseptic loosening after 40 months of operation (6/8). The rate of limb salvage was 90.6% (87/96) and the amputation rate was 9.4% (9/96). The overall survival rate of the prosthesis was 76.7% (5-year) and 47.2% (10-year). The 5-year survival rate was 82.9% for femoral prosthesis and 71.0% for tibial prosthesis, showing no significant difference (P = 0.954). Hinge knee prosthesis still has a high rate of complications. Deep infection is main reason to decrease short-term prosthetic survival rate, and aseptic loosening shortens the long-short prosthetic survival time.
Knee Dislocations in Sports Injuries
Pardiwala, Dinshaw N; Rao, Nandan N; Anand, Karthik; Raut, Alhad
2017-01-01
Knee dislocations are devastating when they occur on the athletic field or secondary to motor sports. The complexity of presentation and spectrum of treatment options makes these injuries unique and extremely challenging to even the most experienced knee surgeons. An astute appreciation of the treatment algorithm is essential to plan individualized management since no two complex knee dislocations are ever the same. Moreover, attention to detail and finesse of surgical technique are required to obtain a good functional result and ensure return to play. Over the past 10 years, our service has treated 43 competitive sportsmen with knee dislocations, and this experience forms the basis for this narrative review. PMID:28966379
The SIGN nail for knee fusion: technique and clinical results.
Anderson, Duane Ray; Anderson, Lucas Aaron; Haller, Justin M; Feyissa, Abebe Chala
2016-02-05
Evaluate the efficacy of using the SIGN nail for instrumented knee fusion. Six consecutive patients (seven knees, three males) with an average age of 30.5 years (range, 18-50 years) underwent a knee arthrodesis with SIGN nail (mean follow-up 10.7 months; range, 8-14 months). Diagnoses included tuberculosis (two knees), congenital knee dislocation in two knees (one patient), bacterial septic arthritis (one knee), malunited spontaneous fusion (one knee), and severe gout with 90° flexion contracture (one knee). The nail was inserted through an anteromedial entry point on the femur and full weightbearing was permitted immediately. All knees had clinical and radiographic evidence of fusion at final follow-up and none required further surgery. Four of six patients ambulated without assistive device, and all patients reported improved overall physical function. There were no post-operative complications. The technique described utilizing the SIGN nail is both safe and effective for knee arthrodesis and useful for austere environments with limited fluoroscopy and implant options.
Schenck, Robert C.; Richter, Dustin L.; Wascher, Daniel C.
2014-01-01
Background: Traumatic knee dislocation is becoming more prevalent because of improved recognition and increased exposure to high-energy trauma, but long-term results are lacking. Purpose: To present 2 cases with minimum 20-year follow-up and a review of the literature to illustrate some of the fundamental principles in the management of the dislocated knee. Study Design: Review and case reports. Methods: Two patients with knee dislocations who underwent multiligamentous knee reconstruction were reviewed, with a minimum 20-year follow-up. These patients were brought back for a clinical evaluation using both subjective and objective measures. Subjective measures include the following scales: Lysholm, Tegner activity, visual analog scale (VAS), Short Form–36 (SF-36), International Knee Documentation Committee (IKDC), and a psychosocial questionnaire. Objective measures included ligamentous examination, radiographic evaluation (including Telos stress radiographs), and physical therapy assessment of function and stability. Results: The mean follow-up was 22 years. One patient had a vascular injury requiring repair prior to ligament reconstruction. The average assessment scores were as follows: SF-36 physical health, 52; SF-36 mental health, 59; Lysholm, 92; IKDC, 86.5; VAS involved, 10.5 mm; and VAS uninvolved, 2.5 mm. Both patients had excellent stability and were functioning at high levels of activity for their age (eg, hiking, skydiving). Both patients had radiographic signs of arthritis, which lowered 1 subject’s IKDC score to “C.” Conclusion: Knee dislocations have rare long-term excellent results, and most intermediate-term studies show fair to good functional results. By following fundamental principles in the management of a dislocated knee, patients can be given the opportunity to function at high levels. Hopefully, continued advances in the evaluation and treatment of knee dislocations will improve the long-term outcomes for these patients in the future. PMID:26535332
10-year evaluation of the cementless low-contact- stress rotating-platform total knee arthroplasty.
Efstathopoulos, Nikolaos; Mavrogenis, Andreas F; Lallos, Stergios; Nikolaou, Vassilios; Papagelopoulos, Panayiotis J; Savvidou, Olga D; Korres, Demetrios S
2009-01-01
We present the clinical and radiographic outcomes of the cementless low-contact-stress (LCS) rotating-platform total knee arthroplasty. Overall, 423 prostheses were implanted in 393 consecutive patients (30 patients had bilateral total knee replacement) for primary varus gonarthrosis (381 patients) and rheumatoid arthritis (12 patients). There were 81 men and 312 women with a mean age of 73 years (range, 58-85 years). Patella replacement was not performed in any case. Clinical and radiographic evaluation was performed using the Knee Society Score (KSS) and the Knee Society Assessment Form, respectively. The mean follow-up was 10 years (range, 5-15 years). Three patients were lost to follow-up. Survival of the prostheses was 98% at 10 years; three prostheses required revision for deep infection, bearing dislocation, and periprosthetic fracture. The mean KSS improved significantly, from 42 and 44 points preoperatively to 90 and 79 points, respectively, at the latest evaluation (P < 0.001); results were excellent in 278 cases, good in 106, fair in 27, and poor in nine. Radiolucent lines were observed in 80 cases; revision arthroplasty was not performed in any of these cases. Complications included deep infection in one patient, bearing dislocation in one, skin necrosis in four, and a supracondylar fracture in one. The cementless LCS rotating-platform total knee arthroplasty is associated with excellent mid- and long-term results for patients with osteoarthritis and rheumatoid arthritis of the knee.
The SIGN nail for knee fusion: technique and clinical results
Anderson, Duane Ray; Anderson, Lucas Aaron; Haller, Justin M.; Feyissa, Abebe Chala
2016-01-01
Purpose: Evaluate the efficacy of using the SIGN nail for instrumented knee fusion. Methods: Six consecutive patients (seven knees, three males) with an average age of 30.5 years (range, 18–50 years) underwent a knee arthrodesis with SIGN nail (mean follow-up 10.7 months; range, 8–14 months). Diagnoses included tuberculosis (two knees), congenital knee dislocation in two knees (one patient), bacterial septic arthritis (one knee), malunited spontaneous fusion (one knee), and severe gout with 90° flexion contracture (one knee). The nail was inserted through an anteromedial entry point on the femur and full weightbearing was permitted immediately. Results: All knees had clinical and radiographic evidence of fusion at final follow-up and none required further surgery. Four of six patients ambulated without assistive device, and all patients reported improved overall physical function. There were no post-operative complications. Conclusion: The technique described utilizing the SIGN nail is both safe and effective for knee arthrodesis and useful for austere environments with limited fluoroscopy and implant options. PMID:27163095
A non-contact complete knee dislocation with popliteal artery disruption, a rare martial arts injury
Viswanath, Y; Rogers, I
1999-01-01
Complete knee dislocation is a rare injury and an associated incidence of popliteal artery damage ranges from 16-60% of cases. It occurs commonly in road traffic accidents and in high velocity trauma where significant contact remains as the usual mode of injury. We describe a rare case of non-contact knee dislocation with popliteal artery injury sustained while practising Aikido, a type of martial art. This patient successfully underwent closed reduction of the knee with an emergency vein bypass graft. Similar injury in association with Aikido has not been described in the English literature previously. Various martial art injuries are briefly discussed and safety recommendations made. Keywords: Aikido; knee dislocation; popliteal artery disruption; sports injury PMID:10616692
Stannard, James P; Sheils, Todd M; Lopez-Ben, Robert R; McGwin, Gerald; Robinson, James T; Volgas, David A
2004-05-01
Popliteal artery injury is frequently associated with knee dislocation following blunt trauma, an injury that is being seen with increasing frequency. The primary purpose of the present study was to evaluate the use of physical examination to determine the need for arteriography in a large series of patients with knee dislocation. The secondary purpose was to evaluate the correlation between physical examination findings and clinically important vascular injury in the subgroup of patients who underwent arteriography. One hundred and thirty consecutive patients (138 knees) who had sustained an acute multiligamentous knee injury were evaluated at our level-1 trauma center between August 1996 and May 2002 and were included in a prospective outcome study. Four patients (four knees) were lost to follow-up, leaving 126 patients (134 knees) available for inclusion in the study. The results of the physical examination of the vascular status of the extremities were used to determine the need for arteriography. The mean duration of follow-up was nineteen months (range, eight to forty-eight months). Physical examination findings, magnetic resonance imaging findings, and surgical findings were combined to determine the extent of ligamentous damage. Nine patients had flow-limiting popliteal artery damage, for an overall prevalence of 7%. Ten patients had abnormal findings on physical examination, with one patient having a false-positive result and nine having a true-positive result. The knee dislocations in the nine patients with popliteal artery damage were classified, according to the Wascher modification of the Schenck system, as KD-III (one knee), KD-IV (seven knees), and KD-V (one knee). Selective arteriography based on serial physical examinations is a safe and prudent policy following knee dislocation. There is a strong correlation between the results of physical examination and the need for arteriography. Increased vigilance may be justified in the case of a patient with a KD-IV dislocation, for whom serial examinations should continue for at least forty-eight hours.
Is peroneal nerve injury associated with worse function after knee dislocation?
Krych, Aaron J; Giuseffi, Steven A; Kuzma, Scott A; Stuart, Michael J; Levy, Bruce A
2014-09-01
Peroneal nerve palsy is a frequent and potentially disabling complication of multiligament knee dislocation, but little information exists on the degree to which patients recover motor or sensory function after this injury, and whether having this nerve injury--with or without complete recovery--is a predictor of inferior patient-reported outcome scores. The purposes of this study were to (1) report on motor and sensory recovery as well as patient-reported outcomes scores of patients with peroneal nerve injury from multiligament knee dislocation; (2) compare those endpoints between patients who had partial versus complete nerve injuries; and (3) compare patient-reported outcomes among patients who sustained peroneal nerve injuries after knee dislocation with a matched cohort of multiligament knee injuries without nerve injury. Thirty-two patients were identified, but five did not have 2-year followup and are excluded (16% lost to followup). Twenty-seven patients (24 male, three female) with peroneal nerve injury underwent multiligament knee reconstruction and were followed for 6.3 years (range, 2-18 years). Motor grades were assessed by examination and outcomes by International Knee Documentation Committee (IKDC) and Lysholm scores. Retrospectively, patients were divided into complete (n = 9) and partial nerve palsy (n = 18). Treatment for complete nerve palsy included an ankle-foot orthosis for all patients, nonoperative (one), neurolysis (two), tendon transfer (three), nerve transfer (one), and combined nerve/tendon transfer (one). Treatment for partial nerve palsy included nonoperative (12), neurolysis (four), nerve transfer (one), and combined nerve/tendon transfer (one). Furthermore, patients without nerve injury were matched by Schenck classification, age, and sex. Data were analyzed using univariate and multivariate models. Overall, 18 patients (69%) regained antigravity ankle dorsiflexion after treatment (three complete nerve palsy [38%] versus 15 partial nerve palsy [83%]; p = 0.06). One patient with complete nerve palsy (13%) and 13 patients with partial nerve palsy (72%) regained antigravity extensor hallucis longus strength (p = 0.01). IKDC and Lysholm scores were similar between complete nerve palsy and partial nerve palsy groups. After controlling for confounding variables such as patient age, body mass index, injury interval to surgery, mechanism of injury, bicruciate injury, and popliteal artery injury status, there was no difference between patients with peroneal nerve injury and those without on Lysholm or IKDC scores. With multiligament knee dislocation and associated peroneal nerve injury, patients with partial nerve injury are more likely to regain antigravity strength when compared with those with a complete nerve injury, but their overall function may not improve. After controlling for confounding variables in a multivariate model, there was no difference in Lysholm or IKDC scores between patients with peroneal nerve injury and those without. Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Arirachakaran, Alisara; Choowit, Pathompong; Putananon, Chinundorn; Muangsiri, Samart; Kongtharvonskul, Jatupon
2015-07-01
To compare clinical outcomes of unicompartmental knee arthroplasty (UKA) versus total knee arthroplasty (TKA). A systematic review and meta-regression to compare postoperative outcomes of pain VAS, knee function score, range of motion, complications and revision surgery rates between UKA and TKA were conducted. Relevant randomized controlled trials were identified from MEDLINE and Scopus from inception to August 29, 2014. Three of 1056 studies were eligible; two, three, two, three and three studies were included in pooling of pain visual analog score (VAS), Knee Society Score (KSS) and Bristol Knee Score (BKS), maximum knee flexion, postoperative complications (aseptic loosening, progressive degenerative joint disease of lateral compartment, bearing dislocation, DVT, fractures and infection) and revision rates, respectively. The unstandardized mean difference (UMD) of the function scores (KSS, BS) for UKA was 1.62 (95 % CI -1.17, 4.42) better than TKA and for pain score was 0.1 (95 % CI -3.54, 3.73) higher than TKA, but both without statistical significance. UKA was more likely to show higher mean maximum knee flexion with a UMD of 1.88 (95 % CI -0.54, 4.30) when compared to TKA, but was also not statistically significant. UKA had a statistically significant lower chance of postoperative complications by 0.35 U (95 % CI 0.12, 0.98) when compared to TKA, but had higher revision rates than TKA with a value of 5.36 (95 % CI 1.06, 27.08). In short-term outcomes (5 years or less, with follow-up of 0-5 years), TKA had higher postoperative complications than UKA, but had lower revision rates. There was only one study that reported long-term survivorship (more than 5 years, with follow-up of 5-15 years). Further research that assesses long-term survivorship is necessary to better evaluate UKA and TKA in the treatment of unicompartmental knee osteoarthritis.
Oh, Kwang-Jun; Yoon, Jung-Ro; Yang, Jae-Hyuk
2013-01-01
Late presentation of congenital patellar dislocation with advanced osteoarthritis is rare. This article presents a case of a 59-year-old man with underlying pseudoachondroplastic dwarfism. Advanced osteoarthritis due to bilateral neglected congenital patellar dislocation was treated with total knee arthroplasty without patella relocation surgery. Two years later, the patient had an improvement in Knee Society scores, painless function, and stability. Copyright © 2012 Elsevier B.V. All rights reserved.
[Trampoline accident with anterior knee dislocation caused popliteal artery disruption].
Pedersen, Peter Heide; Høgh, Annette Langager
2011-10-17
Only a few reports describe the risk of neurovascular damage following knee dislocation while trampolining. A 16 year-old male in a trampoline accident, sustained multi-ligament damage and occlusion of the popliteal artery. The occlusion did not show clinically until 24 hours after the trauma. He underwent vascular surgery (short saphenous bypass). We recommend implementing algorithms, for the management of suspected knee dislocation and possible accompanying neurovascular injuries in all trauma centers.
[Implant with a mobile or a fixed bearing in unicompartmental knee joint replacemen].
Matziolis, G; Tohtz, S; Gengenbach, B; Perka, C
2007-12-01
Although the goal of anatomical and functional joint reconstruction in unicompartmental knee replacement is well defined, no uniform implant design has become established. In particular, the differential indications for implantation of an implant with a mobile or a fixed bearing are still not clear. The long-term results of mobile and with fixed bearings are comparable, but there are significant differences in resulting knee joint kinematics, tribological properties and implant-associated complications. In unicompartmental knee replacement mobile bearings restore the physiological joint kinematics better than fixed implants, although the differences to total knee arthroplasty seem minor. The decoupling of mobile bearings from the tibia implant allows a high level of congruence with the femoral implant, resulting in larger contact areas than with fixed bearings. This fact in combination with the more physiological joint kinematics leads to less wear and a lower incidence of osteolyses with mobile bearings. Disadvantages of mobile bearings are the higher complication and early revision rates resulting from bearing dislocation and impingement syndromes caused by suboptimal implantation technique or instability. Especially in cases with ligamentous pathology fixed bearings involve a lower complication rate. It seems their use can also be beneficial in patients with a low level of activity, as problems related to wear are of minor importance for this subgroup. The data currently available allow differentiations between various indications for implants with mobile or fixed bearings, so that the implants can be matched to the patient and the joint pathology in unicompartmental knee joint replacement.
Dan, Michael; Phillips, Alfred; Simonian, Marcus; Flannagan, Scott
2015-06-01
We provide a review of literature on reduction techniques for posterior hip dislocations and present our experience with a novel technique for the reduction of acute posterior hip dislocations in the ED, 'the rocket launcher' technique. We present our results with six patients with prosthetic posterior hip dislocation treated in our rural ED. We recorded patient demographics. The technique involves placing the patient's knee over the shoulder, and holding the lower leg like a 'Rocket Launcher' allow the physician's shoulder to work as a fulcrum, in an ergonomically friendly manner for the reducer. We used Fisher's t-test for cohort analysis between reduction techniques. Of our patients, the mean age was 74 years (range 66 to 85 years). We had a 83% success rate. The one patient who the 'rocket launcher' failed in, was a hemi-arthroplasty patient who also failed all other closed techniques and needed open reduction. When compared with Allis (62% success rate), Whistler (60% success rate) and Captain Morgan (92% success rate) techniques, there was no statistically significant difference in the successfulness of the reduction techniques. There were no neurovascular or periprosthetic complications. We have described a reduction technique for posterior hip dislocations. Placing the patient's knee over the shoulder, and holding the lower leg like a 'Rocket Launcher' allow the physician's shoulder to work as a fulcrum, thus mechanically and ergonomically superior to standard techniques. © 2015 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Peltola, Erno K; Lindahl, Jan; Koskinen, Seppo K
2014-06-01
The aims of this study were to assess the incidence of reverse Segond fracture, to examine the associated ligamentous injuries, and to examine how often reverse Segond fracture coexists with a knee dislocation. At a level 1 trauma center, an 11-year period of emergency department multidetector-row computed tomography (MDCT) examinations for knee trauma was evaluated for reverse Segond and Segond fractures. Surgical findings served as the reference standard for intra-articular injuries. The hospital discharge register was searched for the diagnosis of knee dislocation from August 2000 through the end of August 2011. A total of 1,553 knee MDCT examinations were evaluated. Ten patients with a reverse Segond fracture were found, comprising 0.64 % of emergency room acute knee trauma MDCT examinations. Seven patients who had a reverse Segond fracture were operated: Three had an avulsion fracture of the anterior cruciate ligament, one had an avulsion fracture of posterior cruciate ligament, two had a lateral meniscal tear, and two had a medial collateral ligament tear. The ratio of reverse Segond fractures to Segond fractures was 1:4. None of the 71 knee dislocation patients had a reverse Segond fracture. Reverse Segond fracture is a rare finding even in a level 1 trauma center. Cruciate ligament injuries appear to be associated with avulsion fracture, but every patient does not have PCL injury, as previously reported. Our results do not support the association of knee dislocation with reverse Segond fracture.
Late dislocation of rotating platform in New Jersey Low-Contact Stress knee prosthesis.
Huang, Chun-Hsiung; Ma, Hon-Ming; Liau, Jiann-Jong; Ho, Fang-Yuan; Cheng, Cheng-Kung
2002-12-01
Five patients with late rotational dislocation of the rotating platform bearing in the New Jersey Low-Contact Stress total knee arthroplasty are reported. The prostheses had functioned well for 8 to 12 years before failure. Preoperative radiographs showed asymmetric femorotibial joint spaces. Entrapment of the dislocated bearing in three patients and spontaneous reduction of the dislocated bearing in another two patients were seen at revision. Femorotibial ligamentous instability was found after reduction. The retrieved polyethylene bearings showed advanced wear and cold flow deformities and the thickness was reduced. The revision arthroplasty was accomplished by replacement with a thicker bearing element. Progressive femorotibial ligament laxity and reduction of the thickness of polyethylene with wearing break down the originally well-balanced soft tissue tension of the knee. The rotational degree of the rotating platform bearing is unrestricted, which may result in late dislocation. Polyethylene wear is unavoidable in knee prostheses using metal contact with polyethylene even with a mobile-bearing design. Efforts to reduce polyethylene wear are mandatory.
... or a blow, sometimes from playing a contact sport. You can dislocate your ankles, knees, shoulders, hips, ... to dislocate it again. Wearing protective gear during sports may help prevent dislocations.
Wang, Shangzeng; Cheng, Shao; Wang, Yisheng
2016-01-01
To evaluate the effectiveness of Oxford mobile-bearing bipolar prosthesis unicompartmental knee arthroplasty (UKA) in the treatment of single compartmental knee osteoarthritis. Between June 2011 and July 2013, 22 cases of single compartmental knee osteoarthritis were treated by Oxford mobile-bearing bipolar prosthesis UKA. Of 22 cases, 8 were male and 14 were female with an average age of 65 years (range, 45-80 years); the left knee was involved in 12 cases, and the right knee in 10 cases, with a mean disease duration of 32.5 months (range, 8-90 months). The mean weight was 55.2 kg (range, 50-65 kg), and the mean body mass index was 20.8 kg/m2 (range, 17-25 kg/m2). Osteoarthritis involved in the single knee medial compartment in all patients. Knee society score (KSS) and range of motion (ROM) were measured to evaluate the knee joint function. Primary healing of incision was obtained in all patients, and there was no complication of infection, bedsore, or deep venous thrombosis. Postoperative follow-up was 2-4 years (mean, 3.2 years). The X-ray films showed good position of prosthesis, no prosthesis dislocation, or periprosthetic infection during follow-up. Knee ROM, KSS function score, and KSS clinical score were significantly improved at 1 week after operation and at last follow-up when compared with preoperative ones (P < 0.05), but no significant difference was shown between at 1 week and at last follow-up (P > 0.05). Oxford mobile-bearing bipolar prosthesis UKA is an effective method to treat single compartmental knee osteoarthritis, with the advantages of less trauma, earlier rehabilitation exercise, near physiological state in joint function, and less risk of complications.
Viswanath, Y K; Rogers, I M
1999-09-01
Complete knee dislocation is a rare injury and an associated incidence of popliteal artery damage ranges from 16-60% of cases. It occurs commonly in road traffic accidents and in high velocity trauma where significant contact remains as the usual mode of injury. We describe a rare case of non-contact knee dislocation with popliteal artery injury sustained while practising Aikido, a type of martial art. This patient successfully underwent closed reduction of the knee with an emergency vein bypass graft. Similar injury in association with Aikido has not been described in the English literature previously. Various martial art injuries are briefly discussed and safety recommendations made.
Ko, Young-Bong; Gujarathi, Manan Ramesh
2015-01-01
The purpose of this systematic review is to collate results of studies comparing fixed and mobile bearing unicompartmental knee arthroplasty (UKA), focusing on complications and timing for reoperations. Out of 723 results derived from PubMed, EMBASE and Cochrane database search engines on bearings in arthroplasty, 10 studies comparing clinical results of fixed bearings to mobile bearings in UKA were found eligible for analysis. The reoperation rate was calculated using a novel method such as reoperations per hundred component years, and the causes of specific reoperations were investigated. The overall reoperation rate per hundred component years was similar between the mobile bearings (1.392) and fixed bearings (1.377); however, mobile bearings were more susceptible to reoperations in cases with aseptic loosening (0.393>0.255), progression of arthritis (0.428>0.357) and implant dislocation (0.286>0). The overall incidence of complications is similar for fixed and mobile bearing designs in UKA. The discussion on complications presented above may assist surgeons in their choice of bearing design. PMID:26389066
[Congenital dislocation of the knee: report of 2 cases].
Ochoa Gómez, L; Sánchez Gimeno, J; García Barrecheguren, E; Marulanda Del Valle, K; Almonte Adón, K; Guerrero Laleona, C
2015-01-01
Congenital dislocation of the knee is a rare disease. The diagnosis is made at birth by clinical findings, and confirmed radiologically. It has been associated with various etiologies from intrauterine fetal malpositions to genetic disorders. The prognosis depends on early treatment and whether there are other congenital anomalies. We report two new cases of congenital dislocation of the knee, observed in our hospital during the period of a month, diagnosed immediately after birth, and both with a good clinical outcome. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Jones, Kevin B.; Griffin, Anthony M.; Chandrasekar, Coonoor R.; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S.; Grimer, Robert J.; Wunder, Jay S.; Ferguson, Peter C.
2011-01-01
Background and Objectives Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Methods 54 TFR patients were identified from 3 institutional prospective databases. 41 had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n=27 were compared between groups and to cohorts of PFR (n=31) and DFR (n=85) patients using the Mann-Whitney U test. Results Follow-up averaged 4 years. Mechanical complications included 5 hip dislocations and 1 femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3±17.8, statistically decreased from DFR (p=0.002) and PFR patients (p=0.036). No significant differences were detected between patients in the fixed-hinge (n=18) and rotating-hinge (n=9) groups (p = 0.944), or total hip (n=8) and hemiarthroplasty (n=19) groups (p=0.633). Conclusions TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. PMID:21695701
Neglected locked vertical patellar dislocation
Gupta, Rakesh Kumar; Gupta, Vinay; Sangwan, Sukhbir Singh; Kamboj, Pradeep
2012-01-01
Patellar dislocations occurring about the vertical and horizontal axis are rare and irreducible. The neglected patellar dislocation is still rarer. We describe the clinical presentation and management of a case of neglected vertical patellar dislocation in a 6 year-old boy who sustained an external rotational strain with a laterally directed force to his knee. Initially the diagnosis was missed and 2 months later open reduction was done. The increased tension generated by the rotation of the lateral extensor retinaculum kept the patella locked in the lateral gutter even with the knee in full extension. Traumatic patellar dislocation with rotation around a vertical axis has been described earlier, but no such neglected case has been reported to the best of our knowledge. PMID:23162154
Volpin, Andrea; Kini, S G; Meuffels, D E
2017-03-31
There exist limited options for treatment of patients with combined medial compartment arthritis and anterior cruciate ligament (ACL) deficiency. Ideal treatment is one that offers lasting relief of symptoms not compromising any future surgery. Unicompartmental knee replacement has shown consistently good results in the relatively young and active population, but there is a high reported incidence of failure up to 20%, if performed in ACL-deficient knees. One of the recognized treatment modality is combined ACL reconstruction and unicompartmental arthroplasty. A systematic review was conducted looking at the demographics, techniques, complications and outcome of combined ACL reconstruction with unicompartmental knee arthroplasty. A systematic literature search within the online Medline, PubMed Database, EMBASE, Web of Science, Cochrane and Google Scholar was carried out until October 2016 to identify relevant articles. A study was defined eligible if it met the following inclusion criteria: the surgical procedure combined unicompartmental knee arthroplasty and anterior cruciate ligament reconstruction; patient's clinical and/or functional outcomes were reported; any complications intra-operatively and post-operatively were reported; and the full-text articles, written in English, German, Italian, Dutch or Spanish, were available. Quality and risk of bias assessments were done using standardized criteria set. A total of 8 studies met the inclusion criteria encompassing 186 patients who were treated with simultaneous ACL reconstruction and unicompartmental knee arthroplasty. The mean age was 50.5 years (range from 44 to 56) with a mean follow-up of 37.6 months (range from 24 to 60). There was an improvement in mean Oxford Score from 27.5 to 36.8. Complications reported included tibial inlay dislocation (n = 3), conversion to a total knee arthroplasty (n = 1), infection requiring two-stage revision (n = 2), deep-vein thrombosis (n = 1), stiffness requiring manipulation under anaesthesia (n = 1), retropatellar pain requiring arthroscopic adhesiolysis (n = 1). Unicompartmental knee arthroplasty combined with ACL reconstruction can be a valid treatment option for selected patients, with combined medial unicompartmental knee osteoarthritis and ACL deficiency. Systematic Review of Level IV Studies, Level IV.
The 180° spin of meniscal bearing in unicompartmental knee arthroplasty.
Lee, Su Chan; Hwang, Seung Hyun; Nam, Chang Hyun; Ryu, Seung Ryol; Ahn, Hye Sun
2017-01-01
Mobile-bearing Oxford medial unicompartmental knee arthroplasty (UKA) has been widely used and has produced good results in the treatment of medial compartmental osteoarthritis. But it is associated with the potential risk of meniscal bearing dislocation. Symptoms caused by most meniscal bearing dislocations include acute pain, knee swelling, and locking. We report two unusual cases of meniscal bearing spinning of 180° without remarkable symptoms, which would have been easily missed if we had not watched carefully. Therefore, if there is sudden locking, pain, swelling, or a slight locking history, the possibility of meniscal bearing spin out as well as meniscal bearing dislocation should be considered and the direction of meniscal bearing markers should be confirmed, especially on lateral radiographs.
Lateral patellar dislocation: mechanism of disease, radiographic presentation, and management.
Abramov, Michael; Stock, Harlan
2013-04-01
Lateral patellar dislocation is a common injury occurring in young active adults. The mechanism is that of twisting injury to the knee on a planted foot with valgus stress. Several predisposing factors, including femoral trochlear dysplasia, patella alta, and lateralization of the tibial tuberosity, contribute to patellar instability and lateral patellar dislocation. Magnetic resonance (MR) imaging of the knee is the modality of choice to evaluate underlying bone contusion patterns, associated soft-tissue injuries, and additional complex ligamentous and osteochondral injuries, many of which are not apparent on conventional radiographs.
NASA Astrophysics Data System (ADS)
Qin, Le; Li, Mei; Yao, Weiwu; Shen, Ji
2017-01-01
We aimed to assess the CT-based bony tunnel valuations and their correlation with knee function after patellar dislocation triple surgeries. A retrospective study was performed on 66 patients (70 knees) who underwent patellar dislocation triple surgeries. The surgery was MPFL reconstruction primarily, combined with lateral retinaculum release and tibial tubercle osteotomy. CT examinations were performed to determine the femoral tunnel position, along with the patellar and femoral tunnel width 3 days and more than 1 year after operation for follow-up. Functional evaluation based on Kujala and Lysholm scores was also implemented. We compared tunnel width of the first and last examinations and correlated femoral tunnel position of the last examination with knee function. At the last follow-up, femoral tunnel position in the anterior-posterior direction was moderately correlated with knee function. Femoral tunnel position in the proximal-distal direction was not associated with postoperative knee function. Patellar and femoral tunnel width increased significantly at the last follow-up. However, no significant functional difference was found between patients with and without femoral tunnel enlargement. Our results suggested that the tunnel malposition in anterior-posterior position based on CT was related to impaired knee function during the follow-ups.
Jones, Kevin B; Griffin, Anthony M; Chandrasekar, Coonoor R; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S; Grimer, Robert J; Wunder, Jay S; Ferguson, Peter C
2011-11-01
Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Fifty-four TFR patients were identified from three institutional prospective databases. Forty-one had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n = 27 were compared between groups and to cohorts of PFR (n = 31) and DFR (n = 85) patients using the Mann-Whitney U-test. Follow-up averaged 4 years. Mechanical complications included five hip dislocations and one femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3 ± 17.8, statistically decreased from DFR (P = 0.002) and PFR patients (P = 0.036). No significant differences were detected between patients in the fixed-hinge (n = 18) and rotating-hinge (n = 9) groups (P = 0.944), or total hip (n = 8) and hemiarthroplasty (n = 19) groups (P = 0.633). TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. Copyright © 2011 Wiley Periodicals, Inc.
Jenkins, Walter; Urch, Scott E.; Shelbourne, K. Donald
2010-01-01
Rehabilitation following lateral side knee ligament repair or reconstruction has traditionally utilized a conservative approach. An article outlining a new concept in rehabilitation following ACL reconstruction called the Knee Symmetry Model was recently published13. The Knee Symmetry Model can also be applied to rehabilitation of other knee pathologies including a knee dislocation with a lateral side injury. This Clinical Commentary describes the rehabilitation procedures used with patients who underwent surgery to repair lateral side ligaments, based upon the Knee Symmetry Model. These procedures were used previously to rehabilitate a group of patients with lateral side ligament repair as reported by Shelbourne et al10. Outcome data and subjective knee scores for these patients were recorded via the International Knee Documentation Committee (IKDC) guidelines and modified Noyes survey scores and are summarized in this paper, as previously published. Rehabilitation following lateral side knee ligament repair using guidelines based upon the Knee Symmetry Model appears to provide patients with excellent long-term stability, normal ROM and strength, and a high level of function. PMID:21589671
Avulsion fracture of an ossified pes anserinus tendon post-lateral patellar dislocation.
Albtoush, Omar M; Taib, Abtehag A; Horger, Marius; Springer, Fabian
2018-05-01
The pes anserinus is a common tendon comprising the tendinous insertions of the sartorius, gracilis, and semitendinosus muscles. It inserts at the anteromedial aspect of the tibia and plays a significant role in stabilization of the medial side of the knee joint. The current article presents a case with recurrent lateral patellar dislocations causing chronic stress along the medial knee stabilizers and consecutive enthesophyte formation at the insertion of the pes anserinus tendon that showed a transverse fracture upon a subsequent incident of traumatic lateral patellar dislocation. Avulsion injuries of the pes anserinus tendon are rarely encountered, and to our knowledge, association with recurrent lateral patellar dislocations has not been described before.
21 CFR 888.3480 - Knee joint femorotibial metallic constrained cemented prosthesis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metallic constrained... Knee joint femorotibial metallic constrained cemented prosthesis. (a) Identification. A knee joint... knee joint. The device prevents dislocation in more than one anatomic plane and has components that are...
Can Vascular Injury be Appropriately Assessed With Physical Examination After Knee Dislocation?
Weinberg, Douglas S; Scarcella, Nicholas R; Napora, Joshua K; Vallier, Heather A
2016-06-01
Knee dislocations are rare injuries with potentially devastating vascular complications. An expeditious and accurate diagnosis is necessary, as failing to diagnose vascular injury can result in amputation; however, the best diagnostic approach remains controversial. We asked: (1) What patient factors are predictors of vascular injury after knee dislocation? (2) What are the diagnostic utilities of palpable dorsalis pedis or posterior tibial pulses, and the presence of an ankle-brachial index (ABI) of 0.9 or greater? A database at a Level I trauma center was queried for patients with evidence of knee dislocation, demographic information (age at the time of injury, sex, Injury Severity Score, BMI, mechanism of injury), and the presence of open injury were recorded. One-hundred forty-one patients underwent screening at initial presentation, of whom 26 (24%) underwent early vascular exploration based on an abnormal physical examination. One-hundred five (91%) of the remaining 115 patients were available at a minimum followup of 6 months (mean, 19 ± 10 months). In total, 31 unique patients were excluded, including 10 patients (7%) who were lost to followup before 6 months. Among the 110 patients who met inclusion criteria, the mean age and SD was 37 ± 13 years, and the Injury Severity Score was 15 ± 9. There were 71 males (65%). Logistic regression was used to determine independent correlates of vascular injury. The vascular examination was reviewed for the presence of a palpable pulse in the dorsalis pedis artery, the presence of a palpable pulse in the posterior tibial artery, and whether the ABI in the dorsalis pedis was 0.9 or greater. Contingency tables were generated to assess the sensitivity, specificity, and accuracy of physical examination maneuvers. The physical examination was collectively regarded as "normal" when both pulses were palpable and the ABI was 0.9 or greater. The initial physical examination as just described was considered the diagnostic test being evaluated in this study; "positive" tests were evaluated by and confirmed at vascular surgery, and 6 months clinical followup without symptoms or progressive signs of vascular injury confirmed the absence of injury in the remainder of the patients. Contingency tables were generated again to assess the sensitivity, specificity, and accuracy of the combined physical examination. Increased BMI (odds ratio [OR], 1.077; 95% CI, 1.008-1.155; p = 0.033) and open injuries (OR, 3.366; 95% CI, 1.008-11.420; p = 0.048) were associated with vascular injury. No single physical examination maneuver had a 100% sensitivity for ruling out vascular injury. A normal physical examination (palpable pulses and ABI ≥ 0.9) had 100% sensitivity for ruling out vascular injury. Increased BMI and the presence of open dislocation are associated with a greater risk for vascular injury after knee dislocation. The combination of a palpable dorsalis pedis and posterior tibial pulse combined with an ABI of 0.9 or greater was 100% sensitive for the detection of vascular injury based on clinical followup at 6 months. Level III, diagnostic study.
Inoue, Hiroaki; Atsumi, Satoru; Ichimaru, Shohei; Fujiwara, Hiroyoshi; Kubo, Toshikazu
2014-01-01
Complications of patellar dislocation include osteochondral injury of the lateral femoral condyle and patella. Most cases of osteochondral injury occur in the anterior region, which is the non-weight-bearing portion of the lateral femoral condyle. We describe two patients with osteochondral injury of the weight-bearing surface of the lateral femoral condyle associated with lateral dislocation of the patella. The patients were 18- and 11-year-old females. Osteochondral injury occurred on the weight-bearing surface distal to the lateral femoral condyle. The presence of a free osteochondral fragment and osteochondral injury of the lateral femoral condyle was confirmed on MRI and reconstruction CT scan. Treatment consisted of osteochondral fragment fixation or microfracture, as well as patellar stabilization. Osteochondral injury was present in the weight-bearing portion of the lateral femoral condyle in both patients, suggesting that the injury was caused by friction between the patella and lateral femoral condyle when the patella was dislocated or reduced at about 90° flexion of the knee joint. These findings indicate that patellar dislocation may occur and osteochondral injury may extend to the weight-bearing portion of the femur even in deep flexion, when the patella is stabilized on the bones of the femoral groove. PMID:25506015
Lanting, Brent A; Lau, Adrian; Teeter, Matthew G; Howard, James L
2017-03-01
Infection after total knee arthroplasty (TKA) is a severe complication. It is usually treated with two-stage revision and implantation of a cement spacer. Few studies describe the complications associated with a mobile articulating spacer. This study examined the subluxation of articulating antibiotic spacers in knees and correlated it with prospectively collected early outcome scores after implantation of a revision prosthesis. Staged revisions for 72 infected primary total knee arthroplasties between 2004 and 2012 were examined. The mean age of the patients was 70.2 ± 10.8 years, with 40 right and 32 left knees. Sagittal and coronal subluxation was measured using radiographs prior to second-stage revision and grouped to be within (Group 1) or outside (Group 2) one standard deviation from the mean. Medical Outcomes Study Short Form-12 (SF-12), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Knee Society Score (KSS) were obtained via patient-administered questionnaire. Statistical analysis was carried out to look at the correlation between subluxation and outcome. Significant improvements were observed between the interim outcome scores prior to implantation of a revision prosthesis and scores obtained after second-stage revision. Debonding occurred in 5.6%, and one dislocation was found. Mean coronal subluxation was 4.8 ± 5.5% of the tibia width, in the lateral direction. Coronal subluxation did not affect SF12, WOMAC or KSS outcome scores. Mean sagittal subluxation was 6.1 ± 16.4% posteriorly. However, sagittal subluxation had a significant influence on Knee Society Scores, with Group 2 having a lower mean Knee Society Function Score of 39.3 than Group 1 (60.2) (p = 0.045). Sagittal subluxation did not affect SF12 or WOMAC scores. Sagittal subluxation of the knee may influence the early to midterm outcome scores following a staged revision TKA for infection.
Bilateral recurrent discloation of the patella associated with below knee amputation: A case report
Batra, Sumit; Kumar, Ratnesh; Lenka, Prasanna
2005-01-01
Background Recurrent dislocation of the patella in patients with below knee amputation is a known entity. Abnormally high-riding patella (patella alta) and medial patellofemoral ligament insufficiency in these patients predisposes them to patellar instability. The established treatment of this problem is surgical realignment. Case presentation A 25 year old male patient with bilateral below knee amputation presented with bilateral recurrent dislocation of the patella while walking on knees on uneven ground. Clinical and radiographic studies showed patella alta. A simple shoe modification was used to treat this patient. Conclusions A simple shoe modification can be used to treat such a condition which is otherwise treated surgically. PMID:15717922
Tensho, Keiji; Akaoka, Yusuke; Shimodaira, Hiroki; Takanashi, Seiji; Ikegami, Shota; Kato, Hiroyuki; Saito, Naoto
2015-09-02
The tibial tuberosity-trochlear groove distance is used as an indicator for medial tibial tubercle transfer; however, to our knowledge, no studies have verified whether this distance is strongly affected by tubercle lateralization at the proximal part of the tibia. We hypothesized that the tibial tuberosity-trochlear groove distance is mainly affected by tibial tubercle lateralization at the proximal part of the tibia. Forty-four patients with a history of patellar dislocation and forty-four age and sex-matched controls were analyzed with use of computed tomography. The tibial tuberosity-trochlear groove distance, tibial tubercle lateralization, trochlear groove medialization, and knee rotation were measured and were compared between the patellar dislocation group and the control group. The association between the tibial tuberosity-trochlear groove distance and three other parameters was calculated with use of the Pearson correlation coefficient and partial correlation analysis. There were significant differences in the tibial tuberosity-trochlear groove distance (p < 0.001) and knee rotation (p < 0.001), but there was no difference in the tibial tubercle lateralization (p = 0.13) and trochlear groove medialization (p = 0.08) between the patellar dislocation group and the control group. The tibial tuberosity-trochlear groove distance had no linear correlation with tubercle lateralization (r = 0.21) or groove medialization (r = -0.15); however, knee rotation had a good positive correlation in the patellar dislocation group (r = 0.62). After adjusting for the remaining parameters, knee rotation strongly correlated with the tibial tuberosity-trochlear groove distance (r = 0.69, p < 0.001), whereas tubercle lateralization showed moderate significant correlations in the patellar dislocation group (r = 0.42; p = 0.005). Because the tibial tuberosity-trochlear groove distance is affected more by knee rotation than by tubercle malposition, its use as an indicator for tibial tubercle transfer may not be appropriate. Surgical decisions of tibial tubercle transfer should be made after the careful analysis of several underlying factors of patellar dislocation. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.
Saragaglia, Dominique; Bevand, Adrien; Refaie, Ramsay; Rubens-Duval, Brice; Pailhé, Régis
2018-05-01
The purpose of this study was to present the results of the KAPS® uni knee arthroplasty system, both mobile and fixed bearing with reference to function, alignment and complications in 103 implants with a mean follow-up of nine years. This was a retrospective study of 103 unicompartimental knee arthroplasties in 89 patients operated on between March 2005 and March 2010. The population was composed of 50 males and 39 females, with a mean age of 70.5 ± 7.5 years (41 - 90). Eighty-seven patients had a genu varum deformity (84.5%), one of whom had an osteoid osteoma of the lateral tibial plateau and 16 patients had a genu valgum (15.5%). Eighty-six medial prostheses were implanted (82 mobile bearings and 4 fixed bearings) and 17 lateral prostheses (all fixed bearings) including the osteoid osteoma. At a mean follow-up of 107.5 months (73-138), 72 knees (58 patients) were reviewed (70%). The mean IKS score was of 173 ± 31 points (58 - 200). The mean Oxford knee score was 21 ± 8 points (12 - 50). The cumulated survival rate at a follow up of 132 months was 98.2%. The KAPS® unicompartmental knee arthroplasty gives efficacious and safe outcomes in the majority of cases at a mean follow-up of nine years. The availability of both fixed and mobile bearings with the same instrumentation, allowing to choose the right implant intra-operatively, is a great advantage in order to avoid the occurrence of some complications, specific to mobile bearing prostheses (dislocation and over-correction).
[In situ suture repair procedure of knee dislocation with multiple-ligament injury at acute stage].
Ye, Jingbing; Luo, Dahui; Fu, Weili; He, Xin; Li, Jian
2009-09-01
To investigate the method and the short term clinical effectiveness of in situ suture repair procedure of knee dislocation with multiple-ligament injury at acute stage. From February 2006 to November 2007, 9 patients suffering from single knee closed dislocation with multiple-ligament injury underwent open in situ suture repair procedure with non-absorbable thread and managements of other combined injuries simultaneously. Nine patients included 6 males and 3 females, aged 34-52 years old. The injured knees were left side in 4 cases and right side in 5 cases. Injuries were caused by traffic accident in 8 cases and heavy-weight crushing in 1 case. EMRI and arthroscopic examination showed that all patients suffered from the avulsion injuries of anterior cruciate ligament and posterior cruciate ligament. The time from injury to operation was 4 to 7 days with an average of 5.1 days. No bacterial arthritis occurred after operation. Subcutaneous ligated fat occurred and cured after symptomatic treatment in 2 cases, other incisions healed by first intension. All patients were followed up 12 months. At 12 months postoperatively, 2 patients' flexion range of the suffering knees lost 10 degrees when to compared with normal knees, and the range of motion was from 0 to 125 degrees. The Lysholm knee scores were 83-92 (average 86.3), the results were excellent in 3 cases and good in 6 cases. The posterior drawer test and anterior drawer test were one-degree positive in 3 cases respectively; the Lachman tests were one-degree positive in 5 cases, lateral stress tests were negative in all cases. In situ suture repair procedure of knee dislocation with multiple-ligament injury at acute stage has the advantages such as reliable fixation, simultaneous management of other combined injuries and satisfactory short term effect.
Knee Injuries and Disability Among Enlisted Males in the U.S. Navy.
1985-05-01
derangements (30.8%), and Chondromalacia (19.9%) were the most common knee diagnoses among the 1974 cohort. Estimated annual age- (length-of-service- and pay...ICDA-8 Code Description 724.5 Other knee derangement 729.6 Loose body in knee 729.7 Chondromalacia of knee 729.9 other diseases of knee 822.0, 822.1...injury categories. Dislocated knees (35.2%), other knee derangements (30.8%), and Chondromalacia (19.9) were the most common knee diagnoses identified in
Single-stage revision for fungal peri-prosthetic joint infection: a single-centre experience.
Klatte, T O; Kendoff, D; Kamath, A F; Jonen, V; Rueger, J M; Frommelt, L; Gebauer, M; Gehrke, T
2014-04-01
Fungal peri-prosthetic infections of the knee and hip are rare but likely to result in devastating complications. In this study we evaluated the results of their management using a single-stage exchange technique. Between 2001 and 2011, 14 patients (ten hips, four knees) were treated for a peri-prosthetic fungal infection. One patient was excluded because revision surgery was not possible owing to a large acetabular defect. One patient developed a further infection two months post-operatively and was excluded from the analysis. Two patients died of unrelated causes. After a mean of seven years (3 to 11) a total of ten patients were available for follow-up. One patient, undergoing revision replacement of the hip, had a post-operative dislocation. Another patient, undergoing revision replacement of the knee, developed a wound infection and required revision 29 months post-operatively following a peri-prosthetic femoral fracture. The mean Harris hip score increased to 74 points (63 to 84; p < 0.02) in those undergoing revision replacement of the hip, and the mean Hospital for Special Surgery knee score increased to 75 points (70 to 80; p < 0.01) in those undergoing revision replacement of the knee. A single-stage revision following fungal peri-prosthetic infection is feasible, with an acceptable rate of a satisfactory outcome.
Treating patella fractures with a fixed-angle patella plate-A prospective observational study.
Wild, Michael; Fischer, Kai; Hilsenbeck, Florian; Hakimi, Mohssen; Betsch, Marcel
2016-08-01
Anterior tension wiring using Kirschner wires (K-wires) is still considered the standard treatment for patella fractures, despite its high complication rate. The objective of this prospective clinical study was to evaluate intra- and perioperative complications as well as the clinical outcome of patients with patella fracture treated with a new developed bilateral, polyaxial, fixed-angle 2.7mm patella plate. Between 2011 and 2014 all patients with a patella fracture were included in this prospective study and treated with a fixed-angle patella plate. Avulsion fractures of the inferior or superior pole of the patella were excluded. All fractures were classified according to the AO/OTA fracture classification. During a twelve-month follow up period all intra- and postoperative complications were recorded as well as the time until fracture healing. One year postoperatively the Lysholm Score, the pre- and postoperative Tegner Score, the Hospital for Special Surgery Knee Score (HSS), the Turba Score, the Oxford Knee Score, the Knee injury and Osteoarthritis Outcome Score (KOOS), the Bostman Score and the Iowa Knee Score were surveyed. Altogether, 20 patella fractures in 19 patients were included in this prospective study. The most frequent type of fracture, n=10, was a simple transverse patella fracture (C1), followed by 7 comminuted patella fractures (C3) and 3 T-shaped patella fractures (C2). During the 12-month follow up period two patients treated with the patella plate had a complication. In one patient a superficial wound infection occurred, which was treated successfully with hardware removal and in one patient a fracture dislocation due to an implant failure occurred. X-rays demonstrated complete bony healing in all fractures on average 3.2 months postoperatively. All knee scores showed good to excellent clinical results one year postoperatively. The results of this first clinical study indicate that the fixed-angle patella plate is an effective and safe treatment option for patella fractures with a short operative learning curve. The treatment of communited patella fractures (C3) with a fixed-angle patella plate should be well-considered to avoid distending the indication and biomechanical properties. Copyright © 2016 Elsevier Ltd. All rights reserved.
Management of traumatic patellar dislocation in a regional hospital in Hong Kong.
Lee, H L; Yau, W P
2017-04-01
The role of surgery for acute patellar dislocation without osteochondral fracture is controversial. The aim of this study was to report the short-term results of management of patellar dislocation in our institute. Patients who were seen in our institution with patella dislocation from January 2011 to April 2014 were managed according to a standardised management algorithm. Pretreatment and 1-year post-treatment International Knee Documentation Committee score, Tegner activity level scale score, and presence of apprehension sign were analysed. A total of 41 patients were studied of whom 20 were first-time dislocators and 21 were recurrent dislocators. Among the first-time dislocators, there was a significant difference between patients who received conservative treatment versus surgical management. The conservative treatment group had a 33% recurrent dislocation rate, whereas there were no recurrent dislocations in the surgery group. There was no difference in Tegner activity level scale score or apprehension sign before and 1 year after treatment, however. Among the recurrent dislocators, there was a significant difference between those who received conservative treatment and those who underwent surgery. The recurrent dislocation rate was 71% in the conservative treatment group versus 0% in the surgery group. There was also significant improvement in International Knee Documentation Committee score from 67.7 to 80.0 (P=0.02), and of apprehension sign from 62% to 0% (P<0.01). A management algorithm for patellar dislocation is described. Surgery is preferable to conservative treatment in patients who have recurrent patellar dislocation, and may also be preferable for those who have an acute dislocation.
Li, Li; Wang, Hongbo; He, Yun; Si, Yu; Zhou, Hongyu; Wang, Xin
2018-06-01
Recurrent patellar dislocations were treated via knee arthroscopy combined with C-arm fluoroscopy, and reconstruction of the medial patellofemoral ligaments. Between October 2013 and March 2017, 52 cases of recurrent patellar dislocation [27 males and 25 females; age, 16-47 years (mean, 21.90 years)] were treated. Arthroscopic exploration was performed and patellofemoral joint cartilage injuries were repaired. It was subsequently determined whether it was necessary to release the lateral patellofemoral support belt. Pre-operative measurements were used to decide whether tibial tubercle osteotomy was required. Medial patellofemoral ligaments were reconstructed using autologous semitendinosus tendons. Smith and Nephew model 3.5 line anchors were used to double-anchor the medial patellofemoral margin. On the femoral side, the medial patellofemoral ligament was fixed using 7-cm, absorbable, interfacial compression screws. All cases were followed for 1-40 months (average, 21 months). The Q angle, tibial tuberosity trochlear groove distance, Insall-Salvati index, patellofemoral angle, lateral patellofemoral angle and lateral shift were evaluated on X-Ray images using the picture archiving and communication system. Subjective International Knee Documentation Committee (IKDC) knee joint functional scores and Lysholm scores were recorded. Post-operative fear was absent, and no patellar re-dislocation or re-fracture was noted during follow-up. At the end of follow-up, the patellofemoral angle (0.22±4.23°), lateral patellofemoral angle (3.44±1.30°), and lateral shift (0.36+0.14°) differed significantly from the pre-operative values (all, P<0.05). Furthermore, IKDC and Lysholm scores (87.84+3.74 and 87.48+3.35, respectively) differed significantly from the pre-operative values (both, P<0.05). These findings suggest that, in the short term, recurrent patellar dislocation treatment via knee arthroscopy combined with C-arm fluoroscopy and reconstruction of the medial patellofemoral ligament was effective.
Kitta, Yuki; Niki, Yasuo; Udagawa, Kazuhiko; Enomoto, Hiroyuki; Toyama, Yoshiaki; Suda, Yasunori
2014-03-01
We present a case of an 8-year-old boy diagnosed with melorheostosis who was suffering from severe genu valgum, permanent dislocation of the patella, knee flexion contracture and leg length shortening. Soft tissue contracture of the limb and subsequent joint deformities were reported to represent clinical manifestations of pediatric melorheostosis. As the epiphyseal plate had not closed, patellar reduction was achieved by soft tissue surgical stabilization, including lateral retinacular release, medial retinaculum plication, and transfer of the lateral half of the patellar tendon. At 4 years postoperatively, as a result of improved limb alignment and knee flexion contracture, the leg length shortening has improved, and the patient does not limp and participates in sports activities. Surgical intervention should be performed as early as possible, because genu valgum and external rotation of the tibia may deteriorate with age, rendering the patellar dislocation irreversible in patients with melorheostosis before epiphyseal closure. Copyright © 2012 Elsevier B.V. All rights reserved.
Hua, Xingyi; Tao, Hui; Fang, Wang; Tang, Jian
2016-01-22
Multiple-ligament injured knee (MLIK) is a rare but severe injury. Although the principles of MLIK management have progressed over the past 40 years, there is a paucity of high-quality evidence upon which to base the management of MLIK. Treatment strategies for MLIK are challenging for most orthopedic surgeons, and the optimal treatment remains controversial, especially with regard to repair vs. reconstruction of the ligaments. The aim of the present study was to observe clinical outcomes of single-stage in situ suture repair of knee dislocation with multiple-ligament injury using nonabsorbable suture material. Consecutive patients with MLIK between 2002 and 2010 were included, for a total of 25 patients with knee dislocation. 17 patients (18 knees) with closed knee dislocation with a mean follow-up of 4.8 ± 1.3 years were retrospective analyzed. All patients were treated surgically with single-stage in situ suture repair for all injured ligaments and followed a standardized postoperative rehabilitation protocol. The VAS score, satisfactory score, total SF-36 score, Lysholm score, Tegner score, the Meyers functional rating and the ranges of motion and knee stability were used to evaluate outcomes. At final follow-up, mean visual analog scale score was 2.4 ± 0.9, patient satisfaction score was 8.0 ± 1.1, 36-item Short-Form Health Survey total score was 85.5 ± 10.4, and mean Lysholm score was 87.5 ± 7.7. There were significant differences between mean preinjury and postoperative Tegner activity scores (5.6 ± 1.4 and 3.4 ± 1.7, respectively; P < 0.01) and in mean range of motion between the injured and contralateral knees (112.5 ± 8.4° and 129.6 ± 10.3°, respectively; P < 0.01). At final follow-up, no patient demonstrated obvious ligamentous laxity, and only one patient was unable to return to work. Three patients had knee joint stiffness, two had wound problems (infection or fat liquefaction), and two had heterotopic bone formation. Single-stage in situ suture repair of injured ligaments confers advantages of reliable fixation and early exercise. It could be considered as an alternate and effective option in the dislocation knee with multiple-ligament injury.
Mamatkerimulla; Xu Gang; Wang, Xin; Zhang, Yang; Jia, Yong; Huang, Tao; Xing, Shuxing
2016-04-01
To investigate the effectiveness of one-stage arthroscopic reconstruction and strict immobilization for 6 weeks for treatment of knee dislocation. Between August 2010 and May 2013, 22 cases (22 knees) of knee dislocation were treated with one-stage reconstruction and strict immobilization for 6 weeks. There were 15 males and 7 females, aged 21-54 years (mean, 31.5 years). The left knee and right knee were involved in 8 cases and 14 cases respectively. The disease causes were traffic accident in 12 cases, falling from height in 6 cases, and sports injury in 4 cases. The time between injury and operation was less than 2 weeks in 6 cases, 2-3 weeks in 10 cases, and more than 3 weeks in 6 cases. The results of anterior drawer test, posterior drawer test, and Lachman test were positive in all patients. The posterior displacement of the tibia was more than 10 mm. The results of valgus stress test and varus stress test were positive in 13 cases and 11 cases respectively. The preoperative knee range of motion was (58.2 ± 28.4)°, Lysholm score was 39.7 ± 4.6. All patients had anterior cruciate ligament rupture and posterior cruciate ligament rupture; combined injuries included medial collateral ligament rupture in 11 cases, lateral collateral ligament rupture in 9 cases, both medial and lateral collateral ligament rupture in 2 cases, femoral condylar avulsion fracture in 2 cases, and meniscus injury in 7 cases. No nerve or blood vessel injury was observed. All cases obtained primary healing of incision without infection. All the patients were followed up 12-48 months (mean, 27.8 months). At 12 months after operation, the results of the anterior drawer test, posterior drawer test, Lachman test, valgus stress test, and varus stress test were all negative; the knee range of motion increased was significantly to (121.3 ± 7.9)° (t = 30.061, P = 0.000); Lysholm score was 87.2 ± 6.1, showing significant difference when compared with preoperative score (t = 24.642, P = 0.000). A combination oathogopi osta ge reconstruction and strict immobilization for treatment of knee dislocation is a safe and effective method, good stability and joint function can be achieved.
Kim, Kyung Taek; Kang, Min Soo; Lim, Young Hoon; Park, Jin Woo
2014-01-01
Purpose To evaluate the clinical and radiological results of total knee arthroplasty (TKA) using the anterior-posterior glide (APG) low contact stress (LCS) mobile-bearing system. Materials and Methods We evaluated 130 knees in 117 patients who had undergone TKA with APG LCS mobile-bearing system between September 2005 and July 2007 and could be followed over 5 years. The mean follow-up period was 68 months. The clinical and radiological results were evaluated using the American Knee Society Scoring System, Oxford knee score and the American Knee Society Roentgenographic Evaluation and Scoring System. And we analyzed short-term postoperative complications. Results The average range of motion of the knee joint was 107.9° (range, 70° to 135°) preoperatively and 125.2° (range, 90° to 135°) at the last follow-up. The average knee and functional scores were improved from 39.1 and 42.0 to 71.2 and 75.6, respectively, between the preoperative and last follow-up evaluation. The Oxford knee score was decreased from 42.9 preoperatively to 23.1 at the last follow-up. The femoro-tibial angle (anatomical axis) changed from 10.1° varus preoperatively to 3.3° valgus at the last follow-up. Radiolucency was observed in 14% of all cases. There were 1 case of traumatic dislocation of the polyethylene liner, 1 case of aseptic loosening and 6 cases of posterior instability because of posterior cruciate ligament (PCL) insufficiency. Conclusions TKA with APG LCS mobile-bearing system demonstrated relatively good short-term clinical and radiological results. However, further considerations for posterior instability associated with PCL insufficiency are needed. PMID:25229046
Normal anatomy and biomechanics of the knee.
Flandry, Fred; Hommel, Gabriel
2011-06-01
Functionally, the knee comprises 2 articulations-the patellofemoral and tibiofemoral. Stability of the joint is governed by a combination of static ligaments, dynamic muscular forces, meniscocapsular aponeurosis, bony topography, and joint load. The surgeon is ill equipped to undertake surgical treatment of a dislocated knee without a sound footing in the anatomic complexities of this joint. We review the normal anatomy of the knee, emphasizing connective tissue structures and common injury patterns.
Camathias, Carlo; Studer, Katrin; Kiapour, Ata; Rutz, Erich; Vavken, Patrick
2016-11-01
The essential static patellar stabilizer is a normal-shaped trochlear groove. A dysplastic groove destabilizes the patella. Trochleoplasty approaches this underlying condition and reshapes the trochlea. However, studies have reported on trochleoplasty for revision cases or as accompanied by other interventions. The effect of trochleoplasty alone remains unexplained. To introduce trochleoplasty as a stand-alone treatment for recurrent patellar dislocation and to compare its pre- to postoperative functional and clinical variables. Case series; Level of evidence, 4. A trochleoplasty was performed in 50 knees (27 right) in 44 patients (30 females; mean ± SD age, 15.6 ± 2.0 years). The indication for surgery was recurrent patellar dislocation not responding to nonoperative treatment (>6 months), with types B through D dysplasia and closed or closing physes in adolescents aged 10 to 20 years. Assessment included J-sign and apprehension test, Kujala and Lysholm scores, patients' subjective assessment and activity level according to the International Knee Documentation Committee questionnaire, and patients' overall satisfaction. The Caton-Deschamps ratio and the lateral condyle index were measured. Pre- versus postoperative values were compared with a paired Wilcoxon signed-rank test. The minimum follow-up was 24 months (33 ± 10.6 months). The Kujala score improved from 71 preoperatively to 92 postoperatively (P < .001) and the Lysholm score from 71 to 95 (P < .001). Patients' subjective assessment improved at the final follow-up as compared with that preoperatively (P < .001). Most patients enhanced their activity (P < .001), and their overall satisfaction increased postoperatively (P < .001). Preoperatively, there was a positive J-sign in 45 knees and a positive apprehension test in 41 knees. Both markers disappeared postoperatively in 39 and 33 knees, respectively, leaving 6 knees with a positive J-sign and 8 knees with a positive apprehension test (P < .001). One patella redislocated postoperatively after 38 months. Four patients required a single arthroscopic debridement. In this study, trochleoplasty as a solitary treatment for recurrent patellofemoral dislocations in patients with trochlear dysplasia resulted in good clinical outcomes if severe torsional and axial malalignment was excluded. Kujala and Lysholm scores increased postoperatively, as well as subjective International Knee Documentation Committee assessment of outcomes, activity level, and overall satisfaction. © 2016 The Author(s).
Rare cause of knee pain after martial arts demonstration: a case report.
Armstrong, Marc B; Thurber, Jalil
2013-04-01
Patellar dislocations are a commonly treated injury in the Emergency Department (ED), with a majority of cases involving lateral subluxation of the patella outside of the joint space. Intra-condylar dislocations of the patella are rare. Of the two types of axis rotation, vertical and horizontal, the vertical occurs five times less frequently. These injuries most often undergo open reduction or, at best, closed reduction under general anesthesia. To remind Emergency Physicians to consider this injury in any patient with severe knee pain and limited mobility, even with a history that is lacking significant trauma. We present a case of intra-condylar patellar dislocation with vertical axis rotation. This injury is no longer primarily attributed to the young and, barring fracture, closed reduction in the ED should be considered. Copyright © 2013 Elsevier Inc. All rights reserved.
Spontaneous superior patellar dislocation in young age: case report and reduction technique
Umar, Muhammad
2017-01-01
Abstract Superior patellar dislocation is a very rare pathology, which happens in middle age. We report a case of spontaneous superior patellar dislocation, which occurred at 30 years of age. Differential diagnosis is patellar tendon rupture, which could be reliably excluded by clinical examination and radiographs. Reduction manoeuvres should be tried with diluted intra-articular local anaesthetic for hydrodilatation to gain mechanical advantage. Splinting the knee in gentle flexion is recommended if general anaesthetic is employed. Recurrent dislocation or osteochondral fractures warrants surgical treatment. PMID:28458846
[Anterior dislocation of the popliteus tendon].
Martinez Molina, Oscar
2009-01-01
Review the most relevant aspects of the posterolateral corner anatomy of the knee, based on the analysis of papers that throughout the years have made important contributions to the knowledge of these structures. Last et al rejected the idea that the popliteal tendon is an isolated structure, suggesting rather that its variants are closely linked to other anatomical structures. The studies by Tria et al contributed the features of the tendon as it attaches to the lateral condyle, just to mention a couple of examples. This is the case of a 48 year-old female patient with a knee injury caused by an external rotation mechanism. Clinical features included pain, a protruding sensation in the lateral aspect of the knee, and voluntary pseudoblocking resulting from external rotation maneuvers. Knee arthroscopy was performed and dislocation of the popliteal tendon anterior to the lateral condyle was diagnosed, besides a longitudinal tear. The tendon was repositioned, radiofrequency was applied to both the tendon and the popliteal hiatus, and the former was kept in place with a plaster cast worn for 6 weeks. Even though the isolated tear or avulsion of the tendon has already been reported, the dislocation or instability of the popliteal tendon as it relates to the lateral femoral condyle has apparently not been approached yet. As we did in this case, other authors have also confirmed the diagnosis arthroscopically, Naver in 1985, Rose in 1988, and Burstein in 1990.
Babiak, Ireneusz
2012-07-03
Deep infection of a joint endoprosthesis constitutes a threat to the stability of the implant and joint function. It requires a comprehensive and interdisciplinary approach, involving the joint revision and removal of the bacterial biofilm from all tissues, the endoprosthesis must be often removed and bone stock infection treated. The paper presents the author's experience with the use of acrylic cement spacers, custom-made during the surgery and containing low dose of an antibiotic supplemented with 5% of a selected, targeted antibiotic for the infection of hip and knee endoprostheses. 33 two-stage revisions of knee and hip joints with the use of a spacer were performed. They involved 24 knee joints and 9 hip joints. The infections were mostly caused by staphylococci MRSA (18) and MSSA (8), and in some cases Enterococci (4), Salmonella (1), Pseudomonas (1) and Acinetobacter (1). The infection was successfully treated in 31 out of 33 cases (93.93%), including 8 patients with the hip infection and 23 patients with the knee infection. The endoprosthesis was reimplanted in 30 cases: for 7 hips and 23 knees, in 3 remaining cases the endoprosthesis was not reimplanted. Mechanical complications due to the spacer occurred in 4 cases: 3 dislocations and 1 fracture (hip spacer). The patients with hip spacers were ambulatory with a partial weight bearing of the operated extremity and those with knee spacers were also ambulatory with a partial weight bearing, but the extremity was initially protected by an orthosis. The spacer enables to maintain a limb function, and making it by hand allows the addition of the specific bacteria targeted antibiotic thus increasing the likelihood of the effective antibacterial treatment.
Higher revision risk for unicompartmental knee arthroplasty in low-volume hospitals
Espehaug, Birgitte; Indrekvam, Kari; Havelin, Leif I; Furnes, Ove
2014-01-01
Background and purpose Some studies have found high complication rates and others have found low complication rates after unicompartmental knee arthroplasty (UKA). We evaluated whether hospital procedure volume influences the risk of revision using data from the Norwegian Arthroplasty Register (NAR). Materials and methods 5,791 UKAs have been registered in the Norwegian Arthroplasty Register. We analyzed the 4,460 cemented medial Oxford III implants that were used from 1999 to 2012; this is the most commonly used UKA implant in Norway. Cox regression (adjusted for age, sex, and diagnosis) was used to estimate risk ratios (RRs) for revision. 4 different volume groups were compared: 1–10, 11–20, 21–40, and > 40 UKA procedures annually per hospital. We also analyzed the reasons for revision. Results and interpretation We found a lower risk of revision in hospitals performing more than 40 procedures a year than in those with less than 10 UKAs a year, with an unadjusted RR of 0.53 (95% CI: 0.35–0.81) and adjusted RR of 0.59 (95% CI: 0.39–0.90). Low-volume hospitals appeared to have a higher risk of revision due to dislocation, instability, malalignment, and fracture than high-volume hospitals. PMID:24847789
Temporo-mandibular joint dislocation: an unusual complication of transoesophageal echocardiography.
Anantharam, Brijesh; Chahal, Navtej; Stephens, Nigel; Senior, Roxy
2010-03-01
Temporo-mandibular joint (TMJ) dislocation is an unusual complication of transoesophageal echocardiography (TEE). We report a rare case of bilateral TMJ dislocation in an 84-year-old man prior to DC cardioversion (DCCV) for atrial flutter. Shortly after TEE and DCCV, the patient complained of bilateral facial pain. An orthopantomogram revealed bilateral TMJ dislocation. A closed reduction was performed by maxillo-facial surgeons under intravenous anaesthesia. Although very uncommon, the physician should be aware of the complication and its management.
NASA Technical Reports Server (NTRS)
Neudeck, P. G.; Huang, W.; Dudley, M.
1998-01-01
It is well-known that SiC wafer quality deficiencies are delaying the realization of outstandingly superior 4H-SiC power electronics. While efforts to date have centered on eradicating micropipes (i.e., hollow core super-screw dislocations with Burgers vector greater than 2c), 4H-SiC wafers and epilayers also contain elementary screw dislocations (i.e., Burgers vector = lc with no hollow core) in densities on the order of thousands per sq cm, nearly 100-fold micropipe densities. This paper describes an initial study into the impact of elementary screw dislocations on the reverse-bias current-voltage (I-V) characteristics of 4H-SiC p(+)n diodes. First, Synchrotron White Beam X-ray Topography (SWBXT) was employed to map the exact locations of elementary screw dislocations within small-area 4H-SiC p(+)n mesa diodes. Then the high-field reverse leakage and breakdown properties of these diodes were subsequently characterized on a probing station outfitted with a dark box and video camera. Most devices without screw dislocations exhibited excellent characteristics, with no detectable leakage current prior to breakdown, a sharp breakdown I-V knee, and no visible concentration of breakdown current. In contrast devices that contained at least one elementary screw dislocation exhibited a 5% to 35% reduction in breakdown voltage, a softer breakdown I-V knee, and visible microplasmas in which highly localized breakdown current was concentrated. The locations of observed breakdown microplasmas corresponded exactly to the locations of elementary screw dislocations identified by SWBXT mapping. While not as detrimental to SiC device performance as micropipes, the undesirable breakdown characteristics of elementary screw dislocations could nevertheless adversely affect the performance and reliability of 4H-SiC power devices.
[Traumatic knee dislocation with popliteal vascular disruption: retrospective study of 14 cases].
Bonnevialle, P; Chaufour, X; Loustau, O; Mansat, P; Pidhorz, L; Mansat, M
2006-12-01
Complex femorotibial dislocation of the knee joint generally results from high-energy trauma caused by a traffic or a contact sport accident. Besides disruption of the cruciate ligaments, in 10-25% of patients present concomitant palsy of the common peroneal nerve and more rarely disruption of the popliteal artery. The purpose of this work was to assess outcome in a monocentric consecutive series of knee dislocations with ischemia due to disruption of the popliteal artery and to focus on specific aspects of management. This retrospective series included eleven men and three women, aged 18 to 74 years (mean 47 years). The right knee was injured in five and the left knee in six. Trauma resulted from a farm accident in six patients, fall from a high level in two, a traffic accident in three and a skiing accident (fall) in one. Two other patients with morbid obesity were fall victims. Nine patients had a single injury, two presented an associated serious head injury, one a severe chest injury, and one multiple trauma with coma, chest contusion, and abdominal lesions. One patient had a fracture of the distal femur with associated ischemia. Five knee dislocations were open with a popliteal wound for three and a posteromedial wound for two. Four patients presented total sciatic nerve palsy and nine palsy of the common peroneal nerve. The dislocation was documented in ten cases: lateral (n=1), anterior (n=4), posterior (n=5). For four patients, the dislocation had been reduced during pre-hospital care. Preoperative arteriography was available for eight patients and confirmed the disruption of the popliteal artery; the diagnosis was obvious in six other patients who were directed immediately to the operative theatre without pre-operative imaging. Revascularization was achieved with a upper popliteal-lower popliteal bypass using an inverted saphenous graft. The graft was harvested from the homolateral greater saphenous vein in eight patients and the contralateral vein in six. On average, limb revascularization was achieved after 10.07 hours ischemia. Intravenous heparin was instituted for 810 days followed by low-molecular-weight heparin. The dislocation was stabilized by a femorotibial fixator in nine patients and a cruropedious cast in five. An incision was made in the anterolateral and posterior leg compartments in twelve patients. A revision procedure was necessary on day one in one patient because of recurrent ischemia; a second bypass using an autologous venous graft was successful. One other 75-year-old patient also presented recurrent ischemia on day five; the bypass was reconstructed but the patient died from multiple injuries. Seven thin skin grafts were used to cover the aponeurotomy surfaces. Mean duration of the external fixator was 3.4 months. The five patients treated with a plaster case were immobilized for 2.7 months on average. Ligament repair was performed in three patients (one lateral reconstruction and one double reconstruction of the central pivot for the two others). A total prosthesis with a rotating hinge was implanted in two patients aged 67 and 74 years after removal of the external fixator at six and seven months. Failure of the ligament repair also led to arthroplasty in a third patient. Blood supply to the lower limb was successfully restored as proven by the renewed coloration of the teguments and-or presence of distal pulses in 13 patients. Transient acute renal failure required dialysis in one patient. Four patients developed pin track discharges and there was one case of septic arthritis of the knee joint which was cured after arthrotomy for wash-out and adapted antibiotics. Outcome was assessed a minimum 18 months follow-up (average 22 months) for the 13 survivors. The three sciatic palsies recovered partially at five and six months in the tibial territory but with persistent paralysis in the territory of the common peroneal nerve. The nine cases of common peroneal nerve palsy noted initially regressed completely or nearly completely in three patients, partially in three and remained unchanged in three. The results were assessed as a function of the final knee procedure: outcome was satisfactory for the patients with a total knee arthroplasty. Outcome of the three ligamentoplasties was good in one, fair in one, and a failure in one (revision arthroplasty). Patients treated by immobilization without a second surgical procedure complained of joint instability with a variable clinical impact; their knee retained active flexion greater than 90 degrees and complete extension. An analysis of the literature and the critical review of our clinical experience was conducted to propose a coherent therapeutic attitude for patients presenting this type of trauma. The prevalence of disruption of the popliteal vascular supply in patients with knee dislocation is between 4 and 20%. The rate is closely related to that of injury to nerves and soft tissue. Ischemia should be immediately suspected in all cases of knee dislocation. The pedious and tibial pulses must be carefully noted before and after reduction of the dislocation to determine whether or not there is an organic arterial lesion. If the pulses are absent initially, they should be expected to reappear strong, rapidly and permanently after reduction. Otherwise, arteriography should be performed. Dislocation stretches the artery between two points of relative anchorage in the adductor ring and the soleus arcade to the point of rupture. Repair requires a bypass between the upper popliteal artery and the tibioperoneal trunk using an inverted saphenous graft because the walls are torn over several centimeters. The traumatology and vascular surgical teams must work in concert from the beginning of the surgical work-up in order to establish a coherent operative strategy founded on primary reduction of the dislocation, installation of a fixator and then vascular repair and aponeurotomy incisions. It would be preferable to wait until the bypass is proven patent and wound healing is complete before proposing ligament repair. This should be done after a precise anatomic work-up to assess each ligament lesion. Bony avulsion or simple disinsertion can however be repaired in the emergency setting at the time of the bypass as well as any ligament rupture which is obvious and-or situated on the medial collateral approach. Secondarily, elements of the central pivot can be repaired in young patients with an important functional demand. Arthroplasty is not warranted except in the elderly patient. Dissection of the popliteal fossa or debridement of the wound enables a careful anatomic assessment of the nerve trunks. In the event of a peroneal nerve disruption, it is advisable to fix the nerve ends to avoid retraction. Beyond three months without clinical or electromyography recovery, surgical exploration is indicated. In the event more than 15 cm is lost, there is no hope for a successful graft. Complete knee dislocation is extremely rare. It can be caused by high-energy trauma associated with several ligament ruptures, particularly rupture of the central pivot observed in 10-25% of cases with common peroneal nerve palsy. Compression, contusion or disruption of the popliteal artery is very rarely caused by the displacement of the femur or the tibia. Limb survival may be compromised. Mandatory emergency restoration of blood supply will modify immediate and subsequent surgical strategies. There has not however been any study exclusively devoted to double joint and vascular involvement. Our objective was to present a critical retrospective analysis of a consecutive series of knee dislocations with ischemia due to disruption of the common popliteal artery treated in a single center and to describe the specific features of management strategies for a coherent diagnostic and therapeutic approach.
A Rare Case of Morel-Lavallee Syndrome Complicating an Anterior Dislocation of Hip Joint.
Nekkanti, Supreeth; Vijay, C; Theja, Sujana; Shankar, R Ravi; Verma, Anubhav
2016-01-01
Hip dislocations are serious injuries as hip joint is an extremely stable joint. It requires a significant amount of force to produce such an injury. Anterior dislocations are uncommon. Potential complications of anterior hip dislocations are a neurovascular injury to femoral vessels or acetabular fractures. We report a rare late complication of Morel-Lavallee syndrome occurring 3 weeks after an anterior dislocation of the hip in a 43-year-old male. The patient presented to us with history. Morel-Lavallee syndrome is a rare complication. However if diagnosed early can be successfully treated with minimal burden to the patient. The authors recommend surgeons to have a high index of suspicion for this syndrome and a stringent follow-up examination of the patient.
Yılmaz, Barış; Çiçek, Esin Derin; Şirin, Evrim; Özdemir, Güzelali; Karakuş, Özgün; Muratlı, Hasan Hilmi
This study compared 20 children hospitalised with acute patellofemoral dislocation with an age-matched healthy control group with no history of knee problems or patellar dislocation. The following morphological parameters were significantly different between the groups: the mean patellar width and length, mean sulcus depth, mean patellar tendon width and total patellar volume. The magnetic resonance imaging findings of this study suggested that structurally smaller than normal patella and patellar tendon volumes are predisposing factors for acute patellofemoral dislocation. Copyright © 2016 Elsevier Inc. All rights reserved.
Choy, Won Sik; Lee, Kwang Won; Kim, Ha Yong; Kim, Kap Jung; Chun, Young Sub; Yang, Dae Suk
2017-08-01
Because Asian populations have different lifestyles, such as squatting and sitting on the floor, from those of Western populations, it is possible that the clinical results and survival rate of unicompartmental knee arthroplasty (UKA) for Asian patients may be different. This study described outcomes of mobile bearing medial UKA for Korean patients. A total of the 164 knees treated with mobile bearing UKAs in 147 patients (14 males and 133 females) were reviewed. The mean follow-up period was 12.1years (range 10.1-14). The clinical outcomes, such as the Hospital for Special Surgery Knee score, the Oxford Knee Score and the Knee Society rating system, showed statistically significant improvement from pre-operative to final follow-up (P<0.05). A total of 26 UKAs (15.8%) required revision; the most common reason was bearing dislocation. The 95% confidence interval of survival rate at 12years was 84.1%, with revision for any reason as the end point. Minimally invasive mobile bearing UKA in Asian patients who required high degrees of knee flexion showed rapid recovery and good clinical outcome. However, they also showed relatively high rates of bearing dislocation and aseptic loosening. Therefore, mobile bearing UKA should only be performed in patients whose lifestyle involves high flexions after carefully considering these risks and benefits. Copyright © 2017 Elsevier B.V. All rights reserved.
Lower limb fractures associated with multiligament knee injury
Stagnaro, Joaquin; Yacuzzi, Carlos; Barla, Jorge; Zicaro, Juan Pablo; Costa-Paz, Matias
2017-01-01
Objectives: Knee ligament injuries related to lower limb fractures are common and frequently unnoticed. Management of acute polytrauma is usually focused in the bone lesion and a complete physical examination might be really difficult. The purpose of this study was to analyze a series of patients who suffered multiligament knee injuries associated to a lower limb fracture. Hypothesis: The use of magnetic resonance imaging (MRI) during the initial management can lead to an early diagnosis of ligament injuries. Methods: A retrospective search was conducted from our hospital´s electronic database. We evaluated the initial diagnosis and acute surgical treatment, and management and functional outcomes after the ligament lesion was diagnosed. Results: Seven patients who presented a knee multiligament injury associated with a lower limb fracture were evaluated. The average age was 29 years. Primary diagnoses were: four tibial plateau fractures; one open fracture-dislocation of the knee; one open leg fracture and ipsilateral hip dislocation; and one bifocal femur fracture. Only three patients had an MRI during the initial management of trauma. Six out of seven patients had to be operated on for the multiligament knee injury. The period between the resolution of the fracture and the ligamentous repair was from 3 to 24 months. Conclusion: Poor functional outcomes are reported in patients with multiligament knee injuries associated with high-energy lower limb fractures. We consider an MRI during the initial management can lead to better outcomes. A trauma surgeon working alongside an arthroscopic surgeon might optimize the results for these lesions.
Qi, Li; Chang, Cao; Xin, Tang; Xing, Pei Fu; Tianfu, Yang; Gang, Zhong; Jian, Li
2011-10-01
To evaluate the effectiveness and safety of a new double fixation technique for displaced patellar fractures using bioabsorbable cannulated lag screws and braided polyester suture tension bands. Fifteen patients (mean age of 46.2 years) with displaced transverse or comminuted patella fractures were enrolled in this prospective study. All of the patients were treated via the open reduction internal fixation (ORIF) procedure using bioabsorbable cannulated lag screws and braided polyester suture tension bands. The patients were followed post-surgery to evaluate (1) the time required for radiographic bone union, (2) the knee joint range of motion at the time of radiographic bone union, (3) the degree of pain assessed using the visual analogue scale (VAS), (4) the function of the knee using the Lysholm score and (5) the presence of any additional complications from the surgery. All of the patients were followed post-treatment for more than 1 year (range, 12-19 months; mean post-treatment follow up time, 14 months). The bone union of the fractures as seen radiographically occurred approximately 3 months from surgery in all cases without implant failure or redisplacement of the fractured site. The mean knee joint range of motion was from 0 to 134.6°, and the mean VAS score was 0.7 at the time of bone union. The mean Lysholm scores at the time of bone union and 12 months post-surgery were 86.7 and 95.7, respectively. No postoperative complications, such as infection, dislocation or breakage of the implants, were observed. Moreover, all of the patients returned to their previous activity level. This new double fixation technique using bioabsorbable cannulated lag screws and braided polyester suture tension bands resulted in satisfactory outcomes for patella fractures without any obvious complications. Copyright © 2011 Elsevier Ltd. All rights reserved.
Dislocation of the proximal tibiofibular joint, do not miss it
van Wulfften Palthe, Alexander FY; Musters, Linda; Sonnega, Remko JA; van der Sluijs, Hans A
2015-01-01
We present a case of a 45-year-old woman with a right proximal tibiofibular dislocation she sustained after a fall during roller skating. Anteroposterior and lateral radiographs confirmed the diagnosis; there were no other injuries. The dislocation was reduced by direct manipulation after intra-articular infiltration, in our emergency department. The patient was treated with a long, non-weight bearing leg cast for 1 week. After 4 weeks, she had no pain and a full range of motion of the knee. PMID:26628303
Patellofemoral Arthritis After Lateral Patellar Dislocation: A Matched Population-Based Analysis.
Sanders, Thomas L; Pareek, Ayoosh; Johnson, Nicholas R; Stuart, Michael J; Dahm, Diane L; Krych, Aaron J
2017-04-01
The rate of patellofemoral arthritis after lateral patellar dislocation is unknown. Purpose/Hypothesis: The purpose of this study was to compare the risk of patellofemoral arthritis and knee arthroplasty between patients who experienced a lateral patellar dislocation and matched individuals without a patellar dislocation. Additionally, factors predictive of arthritis after patellar dislocation were examined. The hypothesis was that the rate of arthritis is likely higher among patients who experience a patellar dislocation compared with those who do not. Cohort study; Level of evidence, 3. In this study, 609 patients who had a first-time lateral patellar dislocation between 1990 and 2010 were compared with an age- and sex-matched cohort of patients who did not have a patellar dislocation. Medical records were reviewed to collect information related to the initial injury, recurrent dislocation, treatment, and progression to clinically significant patellofemoral arthritis (defined as symptoms with degenerative changes on patellar sunrise radiographs). Factors associated with arthritis (age, sex, recurrence, osteochondral injury, trochlear dysplasia) were examined. At a mean follow-up of 12.3 ± 6.5 years from initial dislocation, 58 patients (9.5%) in the dislocation cohort were diagnosed with patellofemoral arthritis, corresponding to a cumulative incidence of arthritis of 1.2% at 5 years, 2.7% at 10 years, 8.1% at 15 years, 14.8% at 20 years, and 48.9% at 25 years. In the control cohort, 8 patients (1.3%) were diagnosed with arthritis, corresponding to a cumulative incidence of arthritis of 0% at 5 years, 0% at 10 years, 1.3% at 15 years, 2.9% at 20 years, and 8.3% at 25 years. Therefore, patients who experienced a lateral patellar dislocation had a significantly higher risk of developing arthritis (hazard ratio [HR], 7.8; 95% CI, 3.9-17.6; P < .001) than individuals without a patellar dislocation. However, the risk of knee arthroplasty was similar between groups (HR, 2.8; 95% CI, 0.6-19.7; P = .2). Recurrent patellar dislocations (HR, 4.5; 95% CI, 1.6-12.6), osteochondral injury (HR, 11.3; 95% CI, 5.0-26.6), and trochlear dysplasia (HR, 3.6; 95% CI, 1.3-10.0) were associated with arthritis after patellar dislocation. Patellar dislocation is a significant risk factor for patellofemoral arthritis, as nearly half of patients have symptoms and radiographic changes consistent with arthritis at 25 years after lateral patellar dislocation. Osteochondral injury, recurrent patellar instability, and trochlear dysplasia are associated with the development of arthritis.
Axillary artery injury secondary to inferior shoulder dislocation.
Plaga, Brad R; Looby, Peter; Feldhaus, Steven J; Kreutzmann, Karl; Babb, Aaron
2010-11-01
Dislocation injuries of the glenohumeral joint are common in the general public and generally are corrected without complication. One serious complication with shoulder dislocations, or the subsequent reduction, is a lesion to the axillary artery. This specific complication is most frequently seen in the elderly population, where vascular structures have become less flexible. Also, these injuries are most common in association with anterior dislocations of the shoulder. To bring awareness to the possibility of axillary artery injury with inferior dislocation of the shoulder, the treatment options, and a review. We report a 15-year-old male athlete who inferiorly dislocated his shoulder during wrestling practice. The injury was reduced at the scene with manual traction and the patient was transferred to our clinic for evaluation. The patient was determined to have a pseudoaneurysm of the axillary artery, and the history and treatment of the illness are presented. Axillary artery injuries secondary to shoulder dislocations are rare, especially in the young athlete, and proper recognition and treatment offer patients a full recovery. Copyright © 2010. Published by Elsevier Inc.
Walker, T; Zahn, N; Bruckner, T; Streit, M R; Mohr, G; Aldinger, P R; Clarius, M; Gotterbarm, T
2018-01-01
The aim of this independent multicentre study was to assess the mid-term results of mobile bearing unicondylar knee arthroplasty (UKA) for isolated lateral osteoarthritis of the knee joint. We retrospectively evaluated 363 consecutive, lateral UKAs (346 patients) performed using the Oxford domed lateral prosthesis undertaken in three high-volume knee arthroplasty centres between 2006 and 2014. Mean age of the patients at surgery was 65 years (36 to 88) with a mean final follow-up of 37 months (12 to 93) RESULTS: A total of 36 (10.5%) patients underwent revision surgery, giving a survival rate of 90.1% at three years (95% confidence intervals (CI) 86.1 to 93.1; number at risk: 155) and 85.0% at five years (95% CI 77.9 to 89.9; number at risk: 43). Dislocation of the mobile bearing occurred in 18 patients (5.6%) at three years (95% CI 1.0 to 16.4; number at risk: 154) and in 20 patients (8.5%) at five years (95% CI 1.0 to 27.0; number at risk: 42). There were no significant differences in the dislocation rate between the participating centres or the surgeons. We were not able to identify an effect of each surgeon's learning curve on the dislocation rate of the mobile bearing. The clinical outcome in patients without revision surgery at final follow-up was good to excellent, with a mean Oxford knee score of 40.3 (95% CI 39.4 to 41.2), a mean Tegner activity score of 3.2 (95% CI 3.1 to 3.3) and a mean University of California, Los Angeles score of 5.7 (95% CI 5.5 to 5.9). Our data, which consists of a high number of patients treated with mobile bearing UKA in the lateral compartment, indicates a high revision rate of 15% at five years with dislocation of the mobile bearing being the main reason for implant failure. Despite the good functional and clinical results and the high patient satisfaction in our study group, we therefore discontinued using mobile-bearing lateral UKA in favour of a fixed-bearing component. Cite this article: Bone Joint J 2018;100-B:42-9. ©2018 The British Editorial Society of Bone & Joint Surgery.
Sun, Zhengyu; Zhang, Chenghao; Tang, Xin; Chen, Gang; Li, Jian
2016-06-08
To evaluate the surgical procedure and short-term effectiveness of one-stage repair and reconstruction of knee dislocation with multiple ligament injuries (KDMLI). Between September 2010 and April 2014, 9 cases (9 knees) of KDMLI were treated. There were 7 males and 2 females with an average age of 42 years (range, 27-57 years). Injury was caused by traffic accident in 3 cases, heavy-weight crushing in 3 cases, sports sprain in 2 cases, and falling from height in 1 case. The average time from injury to operation was 11 days (range, 3-19 days). The results of posterior drawer test and Lachman test were positive in all patients. The results of varus stress testing were three-degree positive in 4 cases, and the results of valgus stress testing were three-degree positive in 6 cases. The Lysholm score of knee was 27.2±6.3; the International Knee Documentation Committee (IKDC) score was 29.7±6.5; and the range of motion (ROM) was (52.6±12.8)°. All patients suffered from posterior cruciate ligament (PCL) injury and femoral avulsion injury of anterior cruciate ligament (ACL). Combined injuries included medial collateral ligament (MCL) injury in 4 cases (medial meniscus injury in 1 case), lateral collateral ligament (LCL) injury in 2 cases, and MCL and LCL injuries in 2 cases (medial meniscus and lateral meniscus injuries in 1 case). Autologous harmstring tendon was used to reconstruct PCL under arthroscopy combined with limited open in situ suture for repair of femoral avulsion injury of ACL, and repair of MCL, LCL, and other injury in one-stage operation. All incisions healed by first intention. Joint effusion of knee occurred in 1 case and was cured after removal of fluid combined with pressure bandage. All patients were followed up 12-36 months with an average of 22 months. At last follow-up, the result of posterior drawer test was negative in all patients. The results of Lachman test were one-degree positive in 2 cases; the result of varus stress testing was one-degree positive in 1 case; the results of valgus stress testing were one-degree positive in 2?cases; and flexion dysfunction of the knee was observed in 1 case. The Lysholm score of knee was 87.3±6.6; the IKDC score was 88.9±6.8; and the ROM was (121.7±12.3)°, all showing significant differences when compared with preoperative ones ( t =44.246, P =0.000; t =37.903, P =0.000; t =19.894, P =0.000). For KDMLI, one-stage repair and reconstruction using autologous harmstring tendon to reconst ruct PCL under arthroscopy combined with limited open in situ suture repair of femoral avulsion injury of ACL, and repair MCL, LCL, and other injury has such advantages as minimal invasiveness, reliable fixation, less complications, and fast recovery, which can significantly improve the stability, ROM, and function of knee and obtain good short-term effectiveness.
Schnaser, Erik; Lee, Yuo-yu; Boettner, Friedrich; Gonzalez Della Valle, Alejandro
2015-08-01
The achievement of a well-balanced total knee arthroplasty is necessary for long-term success. We hypothesize that the dislocation of the patella during surgery affects the distribution of loads in the medial and lateral compartments. Intraoperative load sensors were used to record medial and lateral compartment loads in 56 well-balanced TKAs. Loads were recorded in full extension, relaxed extension, at 45 and 90° of flexion at full gravity-assisted flexion, with the patella in four different positions: dislocated (everted and not), located, and located and secured with two retinacular sutures. The loads in the lateral compartment in flexion were higher with a dislocated patella than with a located patella (P<0.001). A lateralized extensor mechanism artificially increases in the lateral compartment loads in flexion during TKA surgery. Instruments that allow intraoperative soft tissue balance with the patella in a physiologic position are more likely to replicate postoperative compartment loads. II (prospective comparative study). Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Marteau, E; Burdin, P; Brilhault, J-M
2011-06-01
Many surgical techniques for the medial patellofemoral ligament have recently been suggested, all of which included problems identifying the femoral anchorage point and determining the proper extent of knee flexion for the transplant. P. Burdin proposed a different and original approach consisting in performing a gracilis muscle transfer to the medial edge of the patella, thus obtaining progressive tension of the transfer during knee flexion by means of the myotatic reflex. We report the results herein. We retrospectively assessed 17 knees treated for patellofemoral instability using this technique. Two cases presented subjective patellofemoral instability and 15 presented objective patellofemoral instability. The patients' mean age was 17.4 years (range, 8-47 years) during the first episode of dislocation. Two cases of instability were secondary to advanced neuromuscular disease. Two knees had already undergone two stabilization attempts. Fifteen knees presented trochlear dysplasia (four stage A, eight stage B, and three stage C). The mean age at surgery was 28.2 years (range, 16-47 years). In 15 cases, the gracilis transfer was associated with lowering the anterior tibial tuberosity (mean, 10mm). No patellar fracture occurred. A persistent sensory deficit of the anterior branch of the internal saphenous nerve was observed in 15 cases. One knee remained painful and retained subjective instability; total knee arthroplasty was performed 3 years after the intervention. The mean follow-up at revision was 5.5 years (range, 1.5-16.5 years). No recurrence of dislocation was reported. Eight cases retained subjective instability. The SF-36 and IKDC scores were good or excellent in 12 cases and the KOOS was good or excellent in 13 cases. Radiologically, patellar tilt persisted in six cases out of 14, translation persisted in two cases out of 14, and secondary patella baja was observed in one. Medial patellofemoral osteoarthritis was observed in five cases: one case IWANO stage I and four cases IWANO stage II. These satisfactory results seem stable over time and were acquired using a simple procedure with reduced morbidity, making it possible to avoid significant displacement of the anterior tibial tuberosity and stabilize the extensor apparatus. It can also be hoped that the onset of secondary patellofemoral osteoarthritis, undoubtedly inevitable, has been delayed. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Suganuma, Jun; Mochizuki, Ryuta; Inoue, Yutaka; Kitamura, Kazuya; Honda, Akio
2014-02-01
The aim of this study was to investigate the pathoanatomic features of patellar instability by arthroscopically comparing patellofemoral congruence with rotation of the knee joint and/or electrical stimulation of the quadriceps (ESQ) between knees with and without patellar instability. We retrospectively examined 83 knee joints in 83 patients. The joints were classified into 2 groups: group 1 comprised those without a history of patellar dislocation and included 59 patients (25 male and 34 female patients), and group 2 comprised those with a history of patellar dislocation and included 24 patients (9 male and 15 female patients). Evaluation of patellofemoral congruence at 30° of flexion of the knee joint was conducted based on an axial radiograph and arthroscopic findings. The congruence angle was measured on the radiograph. The position of the patellar central ridge (PPCR) on the trochlear groove during arthroscopy was measured using still video frames of knee joints with rotational stress and/or ESQ. Statistical differences in the measurements between the 2 groups were assessed with the unpaired t test and the area under the receiver operating characteristic curve of each measurement. There were significant differences (P < .0001) between the 2 groups in the congruence angle on radiographs and PPCR in knee joints with rotational stress and/or ESQ on arthroscopy. External and internal rotation of the knee joint caused lateral and medial patellar shift, respectively, in both groups, but the shift was significantly larger in group 2. ESQ in addition to rotation caused further patellar shift in group 2 but reduced patellar shift in group 1. Measurement of PPCR with external rotation of the knee and ESQ was the only method to show an area under the receiver operating characteristic curve of 1. There were significant differences in the effects of rotation of the knee joint and/or ESQ on patellofemoral congruence at 30° of flexion of the knee joint on arthroscopy between knees with and without patellar instability. Level III, diagnostic study of nonconsecutive patients. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Report of a new case and clinical delineation of mosaic trisomy 9 syndrome
Sánchez, José María; Fijtman, Nora; Migliorini, Ana María
1982-01-01
A newborn girl with trisomy 9 mosaicism is reported. Clinical findings included major malformations: bilateral hip dislocation, dislocation of the left knee, extreme micrognathia, and microsomy. Up to date, 11 liveborn infants with trisomy 9 have been reported, which allows us to make a karyotype/phenotype correlation. Minimal clinical diagnostic criteria are defined, on the basis of which the presence of this syndrome can be suspected. Images PMID:7143394
Factors Associated with Knee Stiffness following Surgical Management of Multiligament Knee Injuries.
Hanley, Jessica; Westermann, Robert; Cook, Shane; Glass, Natalie; Amendola, Ned; Wolf, Brian R; Bollier, Matthew
2017-07-01
Postoperative knee stiffness can influence outcomes following operative treatment of multiligament knee injuries (MLKIs). The purpose of this study was to evaluate patient and surgical factors that may potentially contribute to stiffness following surgery for MLKIs. All surgically managed MLKIs involving two or more ligaments over a 10-year period at a single level one trauma center were included in this study. A retrospective review was performed to gather objective data related to the development of knee stiffness after surgery. Patients were classified as "stiff" postoperatively if they (1) had a flexion contracture greater than 10 degrees, (2) failed to reach 120 degrees of flexion at final follow-up, or (3) underwent a manipulation under anesthesia with or without arthroscopic lysis of adhesions to improve range of motion. Patient and surgical factors were evaluated systematically to determine factors associated with stiffness. The mean age of the cohort was 27.6 years at the time of surgery and mean follow-up was 50 weeks. Overall, 26/121 (21.5%) knees were diagnosed with postoperative stiffness. In the acute postoperative phase, 17 patients underwent manipulation under anesthesia. There were no significant differences in age, body mass index, associated injuries, mechanism, external fixation use or surgical timing (acute vs. chronic) between stiff and normal knees. Factors associated with the development of postoperative stiffness included knee dislocation ( p = 0.04) and surgical intervention on three or more ligaments ( p = 0.04). Careful attention to postoperative rehabilitation regimens should be given to patients with knee dislocations and/or those undergoing reconstruction or repair of three or more injured ligaments. Surgeons may utilize spanning external fixation if necessary without increasing the rate of long-term stiffness. Further, acute surgery does not appear to influence rates of postoperative stiffness or the need for manipulation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Van Hamersveld, Koen T; Marang-Van De Mheen, Perla J; Van Der Heide, Huub J L; Van Der Linden-Van Der Zwaag, Henrica M J; Valstar, Edward R; Nelissen, Rob G H H
2018-04-01
Background and purpose - Mobile-bearing total knee prostheses (TKPs) were developed in the 1970s in an attempt to increase function and improve implant longevity. However, modern fixed-bearing designs like the single-radius TKP may provide similar advantages. We compared tibial component migration measured with radiostereometric analysis (RSA) and clinical outcome of otherwise similarly designed cemented fixed-bearing and mobile-bearing single-radius TKPs. Patients and methods - RSA measurements and clinical scores were assessed in 46 randomized patients at baseline, 6 months, 1 year, and annually thereafter up to 6 years postoperatively. A linear mixed-effects model was used to analyze the repeated measurements. Results - Both groups showed comparable migration (p = 0.3), with a mean migration at 6-year follow-up of 0.90 mm (95% CI 0.49-1.41) for the fixed-bearing group compared with 1.22 mm (95% CI 0.75-1.80) for the mobile-bearing group. Clinical outcomes were similar between groups. 1 fixed-bearing knee was revised for aseptic loosening after 6 years and 2 knees (1 in each group) were revised for late infection. 2 knees (1 in each group) were suspected for loosening due to excessive migration. Another mobile-bearing knee was revised after an insert dislocation due to failure of the locking mechanism 6 weeks postoperatively, after which study inclusion was preliminary terminated. Interpretation - Fixed-bearing and mobile-bearing single-radius TKPs showed similar migration. The latter may, however, expose patients to more complex surgical techniques and risks such as insert dislocations inherent to this rotating-platform design.
In-game Management of Common Joint Dislocations
Skelley, Nathan W.; McCormick, Jeremy J.; Smith, Matthew V.
2014-01-01
Context: Sideline management of sports-related joint dislocations often places the treating medical professional in a challenging position. These injuries frequently require prompt evaluation, diagnosis, reduction, and postreduction management before they can be evaluated at a medical facility. Our objective is to review the mechanism, evaluation, reduction, and postreduction management of sports-related dislocations to the shoulder, elbow, finger, knee, patella, and ankle joints. Evidence Acquisition: A literature review was performed using the PubMed database to evaluate previous and current publications focused on joint dislocations. This review focused on articles published between 1980 and 2013. Study Design: Clinical review. Level of Evidence: Level 4. Results: The clinician should weigh the benefits and risks of on-field reduction based on their knowledge of the injury and the presence of associated injuries. Conclusion: When properly evaluated and diagnosed, most sports-related dislocations can be reduced and initially managed at the game. PMID:24790695
Colen, David L; Carney, Martin J; Shubinets, Valeriy; Lanni, Michael A; Liu, Tiffany; Levin, L Scott; Lee, Gwo-Chin; Kovach, Stephen J
2018-04-01
Total knee arthroplasty is a common orthopedic procedure in the United States and complications can be devastating. Soft-tissue compromise or joint infection may cause failure of prosthesis requiring knee fusion or amputation. The role of a plastic surgeon in total knee arthroplasty is critical for cases requiring optimization of the soft-tissue envelope. The purpose of this study was to elucidate factors associated with total knee arthroplasty salvage following complications and clarify principles of reconstruction to optimize outcomes. A retrospective review of patients requiring soft-tissue reconstruction performed by the senior author after total knee arthroplasty over 8 years was completed. Logistic regression and Fisher's exact tests determined factors associated with the primary outcome, prosthesis salvage versus knee fusion or amputation. Seventy-three knees in 71 patients required soft-tissue reconstruction (mean follow-up, 1.8 years), with a salvage rate of 61.1 percent, mostly using medial gastrocnemius flaps. Patients referred to our institution with complicated periprosthetic wounds were significantly more likely to lose their knee prosthesis than patients treated only within our system. Patients with multiple prior knee operations before definitive soft-tissue reconstruction had significantly decreased rates of prosthesis salvage and an increased risk of amputation. Knee salvage significantly decreased with positive joint cultures (Gram-negative greater than Gram-positive organisms) and particularly at the time of definitive reconstruction, which also trended toward an increased risk of amputation. In revision total knee arthroplasty, prompt soft-tissue reconstruction improves the likelihood of success, and protracted surgical courses and contamination increase failure and amputations. The authors show a benefit to involving plastic surgeons early in the course of total knee arthroplasty complications to optimize genicular soft tissues. Therapeutic, III.
Neurological complications of the reduction of cervical spine dislocations.
Mahale, Y J; Silver, J R; Henderson, N J
1993-05-01
We have studied the case records of 16 patients with dislocations of the cervical spine who deteriorated neurologically during or after reduction. The dislocations were reduced by skull traction in four patients, by manipulation in four and by operation in seven. This complication was not related to age, sex, mechanism of injury, or the level and the type of dislocation. Fourteen patients made substantial recoveries, one made a partial recovery and one patient remained totally paralysed and died three months later. The causes and prevention of spinal-cord damage at this stage of management are discussed, and the early use of MRI or CT myelography is recommended.
BBilateral Neglected Anterior Shoulder Dislocation with Greater Tuberosity Fractures
Upasani, Tejas; Bhatnagar, Abhinav; Mehta, Sonu
2016-01-01
Introduction: Shoulder dislocations are a very common entity in routine orthopaedic practice. Chronic unreduced anterior dislocations of the shoulder are not very common. Neurological and vascular complications may occur as a result of an acute anterior dislocation of the shoulder or after a while in chronic unreduced shoulder dislocation. Open reduction is indicated for most chronic shoulder dislocations. We report a case of neglected bilateral anterior shoulder dislocation with bilateral displaced greater tuberosity fracture. To the best of our knowledge, only a handful cases have been reported in literature with bilateral anterior shoulder dislocation with bilateral fractures. Delayed diagnosis/reporting is a scenario which makes the list even slimmer and management all the more challenging. Case Report: We report a case of a 35-year-old male who had bilateral anterior shoulder dislocation and bilateral greater tuberosity fracture post seizure and failed to report it for a period of 30 days. One side was managed conservatively with closed reduction and immobilization and the other side with open reduction. No neurovascular complications pre or post reduction of shoulder were seen. Conclusion: Shoulder dislocations should always be suspected post seizures and if found should be treated promptly. Treatment becomes difficult for any shoulder dislocation that goes untreated for considerable period of time PMID:27703939
Pathak, Aditya C; Patil, Atul K; Sheth, Binoti; Bansal, Rohan
2012-01-01
Traumatic neglected dislocations of hip in children are rare entity. Neglected traumatic dislocations of hip in children along with heterotopic ossification are still rare. Post traumatic neglected hip dislocations are to be diagnosed as early as possible and have to be treated with precision and aggression as the outcome of treatment for the same is not predictable. 5 year female with post-traumatic neglected hip dislocation with heterotopic ossification forming a pseudoacetabulum postero-superiorly in which femur head was lodged. The girl was operated by open reduction using Moore's Posterior approach and showed good results. Here is a mention of a rare case with a good 18 months follow up with no complication. Post-traumatic neglected posterior hip dislocation mostly requires open reduction and relocation of femoral head in original acetabulum with concentric reduction. Heterotopic ossification is a rare but known complication of traumatic dislocation of hip in children. Good results can be achieved in such cases and regular follow-up of patient is required post-operatively.
Frings, Jannik; Krause, Matthias; Akoto, Ralph; Wohlmuth, Peter; Frosch, Karl-Heinz
2018-06-04
Valgus deformities of the lower extremity influence patellofemoral joint kinematics. However, studies examining the clinical outcome after treatment of patellar instability and maltracking due to valgus deformity are rare in recent literature. This study's purpose is to analyze the clinical results after combined distal femoral osteotomy (DFO) for treatment of patellar instability. From 2010 to 2016, 406 cases of patellofemoral instability and maltracking were treated. Twenty cases of recurring (≥ 2) patellar dislocations with genu valgum and unsuccessful conservative treatment were included in the study. A radiological analysis was performed, and anteroposterior (AP), lateral and long leg standing radiographs were analyzed, and the leg axis was pre- and postoperatively measured. At least 12 months postoperatively, the clinical leg axis, range of motion (ROM), apprehension sign, Zohlen sign, and J-sign were physically examined. Pain level and knee function were objectified on a visual analogue scale (VAS). The Lysholm, Kujala, and Tegner scores, re-dislocation rate, and patient satisfaction were also examined. 20 combined DFOs on 18 patients with a median age of 23 years (15-55 years) were performed. The preoperative mechanical leg axis was 6.5° ± 2.0° valgus, and the mean tibial tuberosity to trochlear groove (TT-TG) distance was 19.1 ± 4.8 mm. All patients reported multiple dislocations. Intraoperatively, 71% presented III°-IV° cartilage lesions, located retropatellarly in 87% and correlating negatively with the postoperative Lysholm score (r = - 0.462, p = 0.040). The leg axis was corrected by 7.1° ± 2.6°, and in 17 cases, the tibial tubercle was additionally medialized by 10 ± 3.1 mm. All patellae were re-stabilized with medial patellofemoral ligament reconstruction. After a median period of 16 (12-64) months, the pain level decreased from 8.0 ± 1.4 to 2.3 ± 2.1 (VAS p ≤ 0.001) and knee function improved from 40.1 ± 17.9 to 78.5 ± 16.6 (Kujala p ≤ 0.001), 36.1 ± 19.5 to 81.6 ± 11.7 (Lysholm p ≤ 0.001), and 2.0 (1-5) to 4.0 (3-6) (median Tegner p ≤ 0.001). No re-dislocation was observed. Combined DFO is a suitable treatment for patellar instability and maltracking due to genu valgum, as it leads to very low re-dislocation rates, a significant reduction of pain, and a significant increase of knee function with good-to-excellent results in the short-term follow-up. However, a high prevalence of substantial cartilage lesions is observed, causing postoperative limitations of knee function. IV, retrospective cohort study.
[Mixed knee arthrodesis a rescue alternative in knee periprosthetic joint infection].
López-Cervantes, Roberto Enrique; Rivera-Villa, Adrián Huematzin; Miguel-Pérez, Adrián; Morales-de Los Santos, René; Torres-González, Rubén; Pérez-Atanasio, José Manuel
2016-01-01
Knee arthrodesis is a rescue procedure for patients with knee periprosthetic joint infection who are not candidates for a revision surgery. The actual methods present a high complication rate with only moderate efectivity. We retrospectively analyzed 17 cases, of patients with knee periprosthetic joint infection and bone loss treated by intramedular expandable nail and monoplanar external fixator with a mínimum evolution of 1 year, evaluating the medical records and digitalized X-rays by 2 sub specialized doctors in osteoarticular rescue surgery. From the 17 patients, 88.2% were classified as Anderson Orthopaedic Research Institute classification grade (III) and the 11.2% IIB. We obtained fusion in 82.5%, staged Hammer (I-II) in a mean time of 6.33 months. Achieving independent gait was reported in 88.2%. Our complication rate was 47.1%, most of them minor complications except for a supracondylar amputation. Our infection recurrence rate was 35.4%. Mean intervention rate was 2.47 surgeries, all without any operative room complication. We achieved a fusion rate similar to other available knee arthrodesis methods in a similar treatment time; with lower complication rate, making it a suitable rescue alternative for knee arthrodesis in patients with significant bone loss and knee periprosthetic joint infection.
Van Hamersveld, Koen T; Marang-Van De Mheen, Perla J; Van Der Heide, Huub J L; Van Der Linden-Van Der Zwaag, Henrica M J; Valstar, Edward R; Nelissen, Rob G H H
2018-01-01
Background and purpose Mobile-bearing total knee prostheses (TKPs) were developed in the 1970s in an attempt to increase function and improve implant longevity. However, modern fixed-bearing designs like the single-radius TKP may provide similar advantages. We compared tibial component migration measured with radiostereometric analysis (RSA) and clinical outcome of otherwise similarly designed cemented fixed-bearing and mobile-bearing single-radius TKPs. Patients and methods RSA measurements and clinical scores were assessed in 46 randomized patients at baseline, 6 months, 1 year, and annually thereafter up to 6 years postoperatively. A linear mixed-effects model was used to analyze the repeated measurements. Results Both groups showed comparable migration (p = 0.3), with a mean migration at 6-year follow-up of 0.90 mm (95% CI 0.49–1.41) for the fixed-bearing group compared with 1.22 mm (95% CI 0.75–1.80) for the mobile-bearing group. Clinical outcomes were similar between groups. 1 fixed-bearing knee was revised for aseptic loosening after 6 years and 2 knees (1 in each group) were revised for late infection. 2 knees (1 in each group) were suspected for loosening due to excessive migration. Another mobile-bearing knee was revised after an insert dislocation due to failure of the locking mechanism 6 weeks postoperatively, after which study inclusion was preliminary terminated. Interpretation Fixed-bearing and mobile-bearing single-radius TKPs showed similar migration. The latter may, however, expose patients to more complex surgical techniques and risks such as insert dislocations inherent to this rotating-platform design. PMID:29448880
Advanced concepts in knee arthrodesis.
Wood, Jennifer H; Conway, Janet D
2015-03-18
The aim is to describe advanced strategies that can be used to diagnose and treat complications after knee arthrodesis and to describe temporary knee arthrodesis to treat infected knee arthroplasty. Potential difficult complications include nonunited knee arthrodesis, limb length discrepancy after knee arthrodesis, and united but infected knee arthrodesis. If a nonunited knee arthrodesis shows evidence of implant loosening or failure, then bone grafting the nonunion site as well as exchange intramedullary nailing and/or supplemental plate fixation are recommended. If symptomatic limb length discrepancy cannot be satisfactorily treated with a shoe lift, then the patient should undergo tibial lengthening over nail with a monolateral fixator or exchange nailing with a femoral internal lengthening device. If a united knee arthrodesis is infected, the nail must be removed. Then the surgeon has the option of replacing it with a long, antibiotic cement-coated nail. The authors also describe temporary knee arthrodesis for infected knee arthroplasty in patients who have the potential to undergo insertion of a new implant. The procedure has two goals: eradication of infection and stabilization of the knee. A temporary knee fusion can be accomplished by inserting both an antibiotic cement-coated knee fusion nail and a static antibiotic cement-coated spacer. These advanced techniques can be helpful when treating difficult complications after knee arthrodesis and treating cases of infected knee arthroplasty.
Advanced concepts in knee arthrodesis
Wood, Jennifer H; Conway, Janet D
2015-01-01
The aim is to describe advanced strategies that can be used to diagnose and treat complications after knee arthrodesis and to describe temporary knee arthrodesis to treat infected knee arthroplasty. Potential difficult complications include nonunited knee arthrodesis, limb length discrepancy after knee arthrodesis, and united but infected knee arthrodesis. If a nonunited knee arthrodesis shows evidence of implant loosening or failure, then bone grafting the nonunion site as well as exchange intramedullary nailing and/or supplemental plate fixation are recommended. If symptomatic limb length discrepancy cannot be satisfactorily treated with a shoe lift, then the patient should undergo tibial lengthening over nail with a monolateral fixator or exchange nailing with a femoral internal lengthening device. If a united knee arthrodesis is infected, the nail must be removed. Then the surgeon has the option of replacing it with a long, antibiotic cement-coated nail. The authors also describe temporary knee arthrodesis for infected knee arthroplasty in patients who have the potential to undergo insertion of a new implant. The procedure has two goals: eradication of infection and stabilization of the knee. A temporary knee fusion can be accomplished by inserting both an antibiotic cement-coated knee fusion nail and a static antibiotic cement-coated spacer. These advanced techniques can be helpful when treating difficult complications after knee arthrodesis and treating cases of infected knee arthroplasty. PMID:25793160
Treatment of deep infection of total knee arthroplasty using a two-stage procedure.
Pietsch, Martin; Hofmann, Siegfried; Wenisch, Christian
2006-03-01
Treatment of deep infection of total knee arthroplasty by two-stage reimplantation. Using an articulating spacer may reduce the disadvantages of a static spacer (ligament contracture, muscle atrophy, muscle contraction, arthrofibrosis, and bone loss). Restoration of pain-free loading and ability to walk. Late deep infection after total knee arthroplasty. infection occurring at least 6 weeks after the initial arthroplasty. Large metaphyseal bony defects of the distal femur and proximal tibia. Missing or insufficient extensor mechanism. The articulating spacer is made intraoperatively by cleaning and autoclaving the explanted femoral component and the tibial polyethylene insert. These components are reinserted by "press-fit cementing" without cement interdigitation into the trabecular bone. The cement is loaded with antibiotic during the same operation (2-4 g antibiotics per 40 g of cement powder). With the articulating spacer in place, partial weight bearing with crutches and continuous passive motion daily up to a flexion of 90 degrees are allowed. Usually, reimplantation with a standard revision system is scheduled for 6-12 weeks after spacer implantation. In a prospective study 33 consecutive patients were treated from February 2000 to July 2003. The average period of hospitalization after spacer implantation was 14 days (8-26 days). Three patients had recurrent infection (success rate 91%) after a mean follow-up period of 28 months (12-48 months). The average Hospital for Special Surgery Knee Score could be increased from 67 points (44-84 points) preoperatively to 87 points (53-97 points) after reimplantation. The complications were one temporary peroneal palsy, one dislocation of the spacer due to the absence of the extensor ligaments, and one fracture of the tibia due to substantial primary metaphyseal bone loss.
Clinics in diagnostic imaging (163). Transient lateral patellar dislocation with trochlear dysplasia
Zhang, Junwei; Lee, Chin Hwee
2015-01-01
A 14-year-old girl presented with left knee pain and swelling after an injury. Magnetic resonance (MR) imaging showed a transient lateral patellar dislocation with patellar osteochondral fracture, medial patellofemoral ligament tear and underlying femoral trochlear dysplasia. Open reduction and internal fixation of the osteochondral fracture, plication of the medial patellar retinaculum and lateral release were performed. As lateral patellar dislocation is often clinically unsuspected, an understanding of its characteristic imaging features is important in making the diagnosis. Knowledge of the various predisposing factors for patellar instability may also influence the choice of surgical management. We also discuss signs of acute injury and chronic instability observed on MR imaging, and the imaging features of anatomical variants that predispose an individual to lateral patellar dislocation. Treatment options and postsurgical imaging appearances are also briefly described. PMID:26512145
Conventional versus computer-navigated TKA: a prospective randomized study.
Todesca, Alessandro; Garro, Luca; Penna, Massimo; Bejui-Hugues, Jacques
2017-06-01
The purpose of this study was to assess the midterm results of total knee arthroplasty (TKA) implanted with a specific computer navigation system in a group of patients (NAV) and to assess the same prosthesis implanted with the conventional technique in another group (CON); we hypothesized that computer navigation surgery would improve implant alignment, functional scores and survival of the implant compared to the conventional technique. From 2008 to 2009, 225 patients were enrolled in the study and randomly assigned in CON and NAV groups; 240 consecutive mobile-bearing ultra-congruent score (Amplitude, Valence, France) TKAs were performed by a single surgeon, 117 using the conventional method and 123 using the computer-navigated approach. Clinical outcome assessment was based on the Knee Society Score (KSS), the Hospital for Special Surgery Knee Score and the Western Ontario Mac Master University Index score. Component survival was calculated by Kaplan-Meier analysis. Median follow-up was 6.4 years (range 6-7 years). Two patients were lost to follow-up. No differences were seen between the two groups in age, sex, BMI and side of implantation. Three patients of CON group referred feelings of instability during walking, but clinical tests were all negative. NAV group showed statistical significant better KSS Score and wider ROM and fewer outliers from neutral mechanical axis, lateral distal femoral angle, medial proximal tibial angle and tibial slope in post-operative radiographic assessment. There was one case of early post-operative superficial infection (caused by Staph. Aureus) successfully treated with antibiotics. No mechanical loosening, mobile-bearing dislocation or patellofemoral complication was seen. At 7 years of follow-up, component survival in relation to the risk of aseptic loosening or other complications was 100 %. There were no implant revisions. This study demonstrates superior accuracy in implant positioning and statistical significant better functional outcomes of computer-navigated TKA. Computer navigation for TKAs should be used routinely in primary implants. II.
Kneecap dislocation - aftercare
... times a day. This will help reduce swelling. Ice your knee. Make an ice pack by putting ice cubes in a plastic bag and wrapping a ... For the first day of injury, apply the ice pack every hour for 10 to 15 minutes. ...
Results of operative fixation of unstable ankle fractures in geriatric patients.
Pagliaro, A J; Michelson, J D; Mizel, M S
2001-05-01
It is widely accepted that operative fixation of unstable ankle fractures yields predictably good outcomes in the general population. The current literature, however reports less acceptable results in the geriatric population age 65 years and older. The current study analyzes the outcome of the surgical treatment of unstable ankle fractures in patients at least 65 years old. Twenty three patient over 65 years old were surgically treated after sustaining 21 (91%) closed and 2 (9%) open grade II unstable ankle fractures. Fractures were classified according to the Danis-Weber and Lauge-Hansen schemes. Fracture type was predominantly Weber B (21/23, 91%), or supination external rotation stage IV (21/23, 91%). Fracture union rate was 100%. There were three significant complications including a lateral wound dehiscence with delayed fibular union in an open fracture dislocation, and two below knee amputations, neither of which was directly related to the fracture treatment. There were three minor complications; one superficial wound infection and two cases of prolonged incision drainage, all of which resolved without further surgical intervention. Complications were associated with open fractures and preexisting systemic disease. These results indicate that open reduction and internal fixation of unstable ankle fractures in geriatric patients is an efficacious treatment regime that with results that are comparable to the general population.
[Patella fractures in knee arthroplasty].
Roth, A; Ghanem, M; Fakler, J
2016-05-01
Periprosthetic patella fractures occur both with and without retropatellar joint replacement. A non-operative treatment yields satisfactory results with low morbidity. It can be applied in minimally displaced fractures that have an intact retropatellar component and an intact extensor mechanism, combined with an initial immobilization. The surgical treatment is associated with relatively poor results and with high complication rates. There was only minor improvement of functional results, no matter which surgical technique was used. Surgical intervention is still required in fractures with a loosening of the patellar component, considerable dislocations of fragments, and damage to or rupture of the extensor mechanism. In particular, type II fractures require repair of the extensor mechanism and the fracture or patellectomy. Type III fractures require a revision or resection of the patella, a patelloplasty or total patellectomy. In addition, early or late reconstruction using allograft to restore the extensor mechanism can be taken in consideration.
Yamada, Yuzo; Toritsuka, Yukiyoshi; Nakamura, Norimasa; Horibe, Shuji; Sugamoto, Kazuomi; Yoshikawa, Hideki; Shino, Konsei
2017-11-01
The concepts of lateral deviation and lateral inclination of the patella, characterized as shift and tilt, have been applied in combination to evaluate patellar malalignment in patients with patellar dislocation. It is not reasonable, however, to describe the 3-dimensional (3D) positional relation between the patella and the femur according to measurements made on 2-dimensional (2D) images. The current study sought to clarify the relation between lateral deviation and inclination of the patella in patients with recurrent dislocation of the patella (RDP) by redefining them via 3D computer models as 3D shift and 3D tilt. Descriptive laboratory study. Altogether, 60 knees from 56 patients with RDP and 15 knees from 10 healthy volunteers were evaluated. 3D shift and tilt of the patella were analyzed with 3D computer models created by magnetic resonance imaging scans obtained at 10° intervals of knee flexion (0°-50°). 3D shift was defined as the spatial distance between the patellar reference point and the midsagittal plane of the femur; it is expressed as a percentage of the interepicondylar width. 3D tilt was defined as the spatial angle between the patellar reference plane and the transepicondylar axis. Correlations between the 2 parameters were assessed with the Pearson correlation coefficient. The patients' mean Pearson correlation coefficient was 0.895 ± 0.186 (range, -0.073 to 0.997; median, 0.965). In all, 56 knees (93%) had coefficients >0.7 (strong correlation); 1 knee (2%), >0.4 (moderate correlation); 2 knees (3%), >0.2 (weak correlation); and 1 knee (2%), <0.2 (no correlation). The mean correlation coefficient of the healthy volunteers was 0.645 ± 0.448 (range, -0.445 to 0.982; median, 0.834). A statistically significant difference was found in the distribution of the correlation coefficients between the patients and the healthy volunteers ( P = .0034). When distribution of the correlation coefficients obtained by the 3D analyses was compared with that by the 2D (conventional) analyses, based on the bisect offset index and patellar tilt angle, the 3D analyses showed statistically higher correlations between the lateral deviation and inclination of the patella ( P < .01). 3D shift and 3D tilt of the patella were moderately or strongly correlated in 95% of patients with RDP at 0° to 50° of knee flexion. It is not always necessary to use both parameters when evaluating patellar alignment, at least for knees with RDP at 0° to 50° of flexion. Such a description may enable surgeons to describe patellar alignment more simply, leading to a better, easier understanding of the characteristics of each patient with RDP.
Neuerburg, Carl; Bieger, Ralf; Jung, Sebastian; Kappe, Thomas; Reichel, Heiko; Decking, Ralf
2012-08-01
Failed total knee replacement with compromised bone and soft-tissues can be challenging. In these situations, arthrodesis remains a treatment option of a limb-saving procedure. We investigated the outcome of treatment with an intramedullary cemented knee arthrodesis nail implanted in 22 consecutive patients with forlorn situations after failed total knee replacement. There were three major complications due to re-infection and two minor complications due to wound-healing disturbances that healed with the implant retained after an average follow-up of 3.4 years. Clinical examination, Short Form-36 and Oxford knee scores revealed low pain levels, safe implant anchorage, and improved stability of the knee, whilst autonomous mobility utilizing walking aids was still possible. Bridging knee arthrodesis with an intramedullary nail is a valuable salvage procedure with acceptable clinical results. As recurring infection remains the most challenging complication, regular clinical and radiological follow-up examinations are necessary following implant-related knee arthrodesis to allow timely intervention in case of loosening.
Doping and compensation in Al-rich AlGaN grown on single crystal AlN and sapphire by MOCVD
NASA Astrophysics Data System (ADS)
Bryan, Isaac; Bryan, Zachary; Washiyama, Shun; Reddy, Pramod; Gaddy, Benjamin; Sarkar, Biplab; Breckenridge, M. Hayden; Guo, Qiang; Bobea, Milena; Tweedie, James; Mita, Seiji; Irving, Douglas; Collazo, Ramon; Sitar, Zlatko
2018-02-01
In order to understand the influence of dislocations on doping and compensation in Al-rich AlGaN, thin films were grown by metal organic chemical vapor deposition (MOCVD) on different templates on sapphire and low dislocation density single crystalline AlN. AlGaN grown on AlN exhibited the highest conductivity, carrier concentration, and mobility for any doping concentration due to low threading dislocation related compensation and reduced self-compensation. The onset of self-compensation, i.e., the "knee behavior" in conductivity, was found to depend only on the chemical potential of silicon, strongly indicating the cation vacancy complex with Si as the source of self-compensation. However, the magnitude of self-compensation was found to increase with an increase in dislocation density, and consequently, AlGaN grown on AlN substrates demonstrated higher conductivity over the entire doping range.
Nowak, Bernd; Tasche, Karl; Barnewold, Linda; Heller, Günther; Schmidt, Boris; Bordignon, Stefano; Chun, K R Julian; Fürnkranz, Alexander; Mehta, Rajendra H
2015-05-01
Several studies demonstrated an inverse relationship between cardioverter-defibrillator implantation volume and complication rates, suggesting better outcomes for higher volume centres. However, the association of institutional procedural volume with patient outcomes for permanent pacemaker (PPM) implantation remains less known, especially in decentralized implantation systems. We performed retrospective examination of data on patients undergoing PPM from the German obligatory quality assurance programme (2007-12) to evaluate the relationship of hospital PPM volume (categorized into quintiles of their mean annual volume) with risk-adjusted in-hospital surgical complications (composite of pneumothorax, haemothorax, pericardial effusion, or pocket haematoma, all requiring intervention, or device infection) and pacemaker lead dislocation. Overall 430 416 PPM implantations were documented in 1226 hospitals. Systems included dual (72.8%) and single (25.8%) chamber PPM and cardiac resynchronization therapy (CRT) devices (1.1%). Complications included surgical (0.92%), and ventricular (0.99%), and atrial (1.22%) lead dislocation. Despite an increase in relatively complex procedures (dual chamber, CRT), there was a significant decrease in the procedural and fluoroscopy times and complications from lowest to highest implantation volume quintiles (P for trend <0.0001). The greatest difference was observed between the lowest (1-50 implantations/year-reference group) and the second-lowest (51-90 implantations/year) quintile: surgical complications [odds ratio (OR) 0.69; confidence interval (CI) 0.60-0.78], atrial lead dislocations (OR 0.69; CI 0.59-0.80), and ventricular lead dislocations (OR 0.73; CI 0.63-0.84). Hospital annual PPM volume was directly related to indication-based implantation of relatively more complex PPM and yet inversely with procedural times and rates of early surgical complications and lead dislocations. Thus, our data suggest better performance and lower complications with increasing procedural volume. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Tian, Shaoqi; Wang, Bin; Wang, Yuanhe; Ha, Chengzhi; Liu, Lun; Sun, Kang
2016-08-05
Relative young and more active patients with osteoarthritis (OA) of the isolated medial femorotibial compartment in conjunction with anterior cruciate ligament (ACL) deficiency are difficult to treat. The aim of this study was to explore the early clinical outcomes of combined Oxford unicompartmental knee arthroplasty (UKA) and ACL reconstruction for the patients presenting ACL deficiency and isolated OA of the medial compartment. Twenty-eight patients were included into the study. All patients were treated by combined Oxford UKA and ACL reconstruction. Plain radiographs in the antero-posterior and lateral view and long-leg standing radiographs were routinely performed prior to and after surgery. Stress radiographs in valgus were additionally available in order to verify the well-preserved lateral compartment. The varus deformity of the knee prior to surgery and the valgus degree after surgery, the posterior slope of the tibial component and the range of motion (ROM) of the knee after surgery were measured and recorded. Clinical evaluations include Oxford Knee Score (OKS), Knee Society Score (KSS-clinical score; KSS-function score) and Tegner activity score. All the patients were followed up for 52 ± 8 months. The leg alignment showed 3.1 ± 0.6° of varus deformity prior to surgery and 4.0 ± 0.7° of valgus after surgery. The OKS, KSS and Tegner activity score improved significantly after surgery (P < 0.05). The mean ROM of the operated knee was 123.5 ± 2.8° at the last follow-up. The posterior slope of the tibial component was 3.9 ± 1.2°. A significant correlation was found between them according to the Pearson's correlation (r = 0.39, P = 0.03). There were 2 patients (7 %) with the complication of mobile bearing dislocation, and a second operation of replacing a thicker mobile bearing was performed for them. The early clinical data have shown that combined surgery of UKA and ACL reconstruction has revealed promising results. However, long-term follow-up studies should be done in these patients. Current trial ISRCTN24663935 (Retrospectively registered on 21 July 2016).
[Clinical significance of Q-angle under different conditions in recurrent patellar dislocation].
Wang, Zhijie; Chen, You; Li, Anping; Long, Yi
2014-01-01
To investigate the clinical significance of Q-angle measuring under different conditions in female recurrent patellar dislocation female patients. Between August 2012 and March 2013, 10 female patients (11 knees) with recurrent patellar dislocation were collected as trial group; 20 female patients (20 knees) with simple meniscus injury were collected as control group at the same time. Q-angle was measured in extension, 30 degrees flexion, 30 degrees flexion with manual correction, and surgical correction in the trial group, and only in extension and 30 degrees flexion in the control group. Then the difference value of Q-angle between extension and 30 degrees flexion (Q-angle in extension subtracts Q-angle in 30 flexion) were calculated. Independent sample t-test was used to analyze Q-angle degrees in extension, 30 degrees flexion, and the changed degrees of 2 groups. The Q-angle between manual correction and surgical correction of the trial group was analyzed by paired t-test. The Q-angle in extension, Q-angle in 30 degrees flexion, and difference value of Q-angle between extension and 30 degrees flexion were (17.2 +/- 3.6), (14.3 +/- 3.0), and (2.9 +/- 1.9) degrees in the trial group and were (15.2 +/- 3.4), (14.4 +/- 3.5), and (0.8 +/- 1.7) degrees in the control group. No significant difference was found in Q-angle of extension or Q-angle of 30 degrees flexion between 2 groups (P > 0.05), but the difference value of Q-angle between extension and 30 degrees flexion in the trial group was significantly larger than that in the control group (t = 3.253, P = 0.003). The Q-angle in 30 degrees flexion with manual correction and surgical correction in the trial group was (19.8 +/- 3.4) degrees and (18.9 +/- 3.8) degrees respectively, showing no significant difference (t = 2.193, P = 0.053). When a female patient's Q-angle in 30 degrees flexion knee changes obviously compared with Q-angle in extension position, recurrent patellar dislocation should be considered. For female patients with recurrent patellar dislocation, the preoperative Q-angle in 30 degrees flexion with manual correction should be measured, which can help increasing the accuracy of evaluation whether rearrangement should be performed.
Total knee arthroplasty in patients with a prior fracture of the tibial plateau.
Weiss, Nicholas G; Parvizi, Javad; Trousdale, Robert T; Bryce, Rex D; Lewallen, David G
2003-02-01
A fracture of the tibial plateau may predispose the knee to the development of posttraumatic arthritis. Malunion, intra-articular chondro-osseous defects, limb malalignment, retained internal fixation devices, and poor surrounding soft tissues may in turn compromise the outcome of total knee arthroplasty. The aim of our study was to evaluate the results of total knee arthroplasty in patients with a previous fracture of the tibial plateau. The results of sixty-two condylar total knee arthroplasties performed with cement, from 1988 to 1999, in sixty-two patients with a previous fracture of the tibial plateau were reviewed. The fracture of the tibial plateau had been treated by open reduction and internal fixation in thirty-eight knees, external fixation in one knee, and nonoperatively in twenty-three knees. There were forty women and twenty-two men with an average age of sixty-three years at the time of the arthroplasty. Knee Society scores were recorded preoperatively and at the time of follow-up, at an average of 4.7 years, and complications were noted. No patient was lost to follow-up. The mean Knee Society scores improved significantly (p < 0.0001), from 43.9 points for pain and 52 points for function preoperatively to 82.9 and 84 points, respectively, at the time of the latest follow-up. There were thirteen reoperations, which included manipulation with the patient under anesthesia (five knees), wound revision (three knees), and component revision (five knees). There were six intraoperative complications (10%). A postoperative complication occurred in sixteen knees (26%). The vast majority of patients treated with total knee arthroplasty after a previous fracture of the tibial plateau have substantial improvement in function and relief of pain. However, these patients are at increased risk for perioperative complications, as evidenced by the high reoperation rate of 21% in this study.
Timing of Surgical Reduction and Stabilization of Talus Fracture-Dislocations.
Buckwalter V, Joseph A; Westermann, Robert; Mooers, Brian; Karam, Matthew; Wolf, Brian
Talus fractures with associated dislocations are rare but have high rates of complications, including avascular necrosis (AVN). Management of these injuries involves urgent surgical reduction and fixation, although there are no definitive data defining an operative time frame for preserving the blood supply and preventing complications. To determine the effect of time to surgical reduction of talus fractures and talus fracture-dislocations on rates of AVN and posttraumatic osteoarthritis (PTOA), we retrospectively reviewed talus fractures surgically managed at a level I trauma center during the 10-year period 2003 to 2013. Operative reports were obtained and reviewed, and 3 independent reviewers, using the Hawkins and AO/OTA (Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association) systems, classified the injuries on plain radiographs. Analysis of AO/OTA 81 fractures with associated tibiotalar, subtalar, or talonavicular dislocations was performed. Primary outcomes were presence of AVN/PTOA and subsequent arthrodesis of tibiotalar or subtalar joints. We identified 106 surgically managed talus fractures. Rates of AVN/PTOA were 41% for all talus fractures and 50% for talus fracture-dislocations. Mean time to surgical reduction was not significant for development of AVN/PTOA for all talus fractures (P = .45) or talus fracture-dislocations (P = .29). There was no difference in age (P = .20), body mass index (P = .45), or polytrauma (P = .79) between patients who developed AVN and those who did not. Open fractures were significantly correlated with the development of AVN/PTOA (P = .009). Talar fracture-dislocations are devastating injuries with high rates of complications. Our data suggest there is no effect of time from injury to surgical reduction of talus fractures or talus fracture-dislocations on rates of AVN and PTOA.
Quantifying the Risk of Analgesic-Related Adverse Events After Knee Arthroscopy.
Gonzales, Jeff; Lovald, Scott T; Lau, Edmund C; Ong, Kevin L
Opioids are frequently used as part of multimodal pain management protocols for knee arthroscopy; however, their use may be associated with opioid-related adverse events. The purpose of this study was to evaluate the risk of potential analgesic-related complications after knee arthroscopy using a nationally representative database. Using 2010\\endash 2012 Medicare claims data, patients undergoing knee arthroscopy procedures (including ligament repair, meniscectomy, and chondroplasty) were identified. The risk of complications related to typical modalities of analgesia, including opioids, within 90 days following surgery was assessed using multivariate Cox regression. Based on follow-up of 16,567 cases, respiratory complications (bradypnea, pulmonary insufficiency, asphyxia, and hypoxemia) were the most frequently diagnosed complications ( n = 418; 2.52%), followed by postoperative nausea and vomiting ( n = 174; 1.05%) and urinary retention complications ( n = 166; 1.00%). Risk factors including older age, male gender, lower socioeconomic status, and a high number of comorbidities were associated with development of postsurgical complications.
Postural asymmetries in young adults with cerebral palsy.
Rodby-Bousquet, Elisabet; Czuba, Tomasz; Hägglund, Gunnar; Westbom, Lena
2013-11-01
The purpose was to describe posture, ability to change position, and association between posture and contractures, hip dislocation, scoliosis, and pain in young adults with cerebral palsy (CP). Cross-sectional data of 102 people (63 males, 39 females; age range 19-23 y, median 21 y) out of a total population with CP was analysed in relation to Gross Motor Function Classification System (GMFCS) levels I (n=38), II (n=21), III (n=13), IV (n=10), and V (n=20). The CP subtypes were unilateral spastic (n=26), bilateral spastic (n=45), ataxic (n=12), and dyskinetic CP (n=19). The Postural Ability Scale was used to assess posture. The relationship between posture and joint range of motion, hip dislocation, scoliosis, and pain was analysed using logistic regression and Spearman's correlation. At GMFCS levels I to II, head and trunk asymmetries were most common; at GMFCS levels III to V postural asymmetries varied with position. The odds ratios (OR) for severe postural asymmetries were significantly higher for those with scoliosis (OR=33 sitting), limited hip extension (OR=39 supine), or limited knee extension (OR=37 standing). Postural asymmetries correlated to hip dislocations: supine (r(s) =0.48), sitting (r(s) =0.40), standing (r(s) =0.41), and inability to change position: supine (r(s) =0.60), sitting (r(s) =0.73), and standing (r(s) =0.64). Postural asymmetries were associated with scoliosis, hip dislocations, hip and knee contractures, and inability to change position. © 2013 The Authors. Developmental Medicine & Child Neurology published by John Wiley & Sons Ltd on behalf of Mac Keith Press.
Postural asymmetries in young adults with cerebral palsy
Rodby-Bousquet, Elisabet; Czuba, Tomasz; Hägglund, Gunnar; Westbom, Lena
2013-01-01
Aim The purpose was to describe posture, ability to change position, and association between posture and contractures, hip dislocation, scoliosis, and pain in young adults with cerebral palsy (CP). Methods Cross-sectional data of 102 people (63 males, 39 females; age range 19–23y, median 21y) out of a total population with CP was analysed in relation to Gross Motor Function Classification System (GMFCS) levels I (n=38), II (n=21), III (n=13), IV (n=10), and V (n=20). The CP subtypes were unilateral spastic (n=26), bilateral spastic (n=45), ataxic (n=12), and dyskinetic CP (n=19). The Postural Ability Scale was used to assess posture. The relationship between posture and joint range of motion, hip dislocation, scoliosis, and pain was analysed using logistic regression and Spearman’s correlation. Results At GMFCS levels I to II, head and trunk asymmetries were most common; at GMFCS levels III to V postural asymmetries varied with position. The odds ratios (OR) for severe postural asymmetries were significantly higher for those with scoliosis (OR=33 sitting), limited hip extension (OR=39 supine), or limited knee extension (OR=37 standing). Postural asymmetries correlated to hip dislocations: supine (rs=0.48), sitting (rs=0.40), standing (rs=0.41), and inability to change position: supine (rs=0.60), sitting (rs=0.73), and standing (rs=0.64). Conclusions Postural asymmetries were associated with scoliosis, hip dislocations, hip and knee contractures, and inability to change position. This article is commented on by Novak on page 974 of this issue. PMID:23834239
[Imaging of traumatic injuries of the knee].
Blin, D; Cyteval, C; Kamba, C; Blondel, M; Lopez, F M
2007-05-01
Traumatic injuries to the knee are frequent (road or sports related accidents, falls in elderly people). The Ottawa knee rules are applied and dictate the need for additional evaluation. Some fractures are adequately assessed on plain radiographs alone whereas other fractures (tibial plateau fracture) require additional evaluation with CT. Some fractures may be occult: the significance of lipohemarthrosis (indirect sign of intra-articular fracture on the lateral radiograph with horizontal beam) must be known. Benign appearing avulsion fractures suggest the presence of underlying capsuloligamentous injuries requiring further evaluation with MRI. The imaging work-up of sprains is usually negative. MRI may show areas of bone contusion that further the understanding of the mechanism of injury, predict and confirm the presence of capsuloligamentous injuries. Angiography is performed to detect popliteal artery injuries after knee dislocation which is associated with a risk of ischemia.
Tang, Xiao-Bo; Dong, Pei-Long; Wang, Jian
2014-04-01
To compare therapeutic effects between patella replacement and patella osteotomy in total knee arthroplasty. From April 2004 to April 2011, 52 patients (54 knees) were enrolled in the clinical trail of total knee arthroplasty, who received patella replacement (24 knees, including 13 males and 11 females,ranging in age from 53 to 78 years old or patella osteotomy (30 knees,including 16 males and 12 females,ranging in age from 55 to 79 years old. The average follow-up period was 56 months,ranging from 20 to 80 months. The American HSS Score for knee, the Feller score for patella, range of motion (ROM) for knee, patient satisfaction and complications related to the patella were used to evaluate therapeutic effects. In the patella replacement group,the preoperative and final follow-up HSS scores of patients were 38.4 +/- 8.2 and 91.2 +/- 8.6 respectively; Feller scores were 13.6 +/- 6.2 and 25.2 +/- 4.2; scores of anterior knee pain were 3.9 +/- 3.2 and 11.2 +/- 3.7; ROM were (78 +/- 26) degrees and(108 +/- 18) degrees. In the patella osteotomy group,the preoperative and final follow-up HSS scores of patients were 39.5 +/- 8.4 and 91.0 +/- 8.5 respectively;Feller scores were 13.4 +/- 6.5 and 25.6 +/- 4.0; scores of anterior knee pain were 3.7 +/- 3.1 and 11.3 +/- 3.6; ROM were (76 +/- 27) degrees and (110 +/- 19) degrees. In the patella replacement group,patient's satisfaction was 91%, and complication related to the patella was 16.7%; in the patella osteotomy group, patient's satisfaction was 89%, and complications related to the patella was 10.0%. There were no statistically significant differeneces in final follow-up HSS scores, Feller scores, scores of anterior knee pain and ROM between the two groups. However,there was no significant difference of patient's satisfaction between them. There was statistically significant differenece of patella-related complications between the two groups, and the complication rate in the patella replacement group was higher than that in the patella osteotomy group. Total knee arthroplasty with patella replacement or patella osteotomy dramatically relieves pain and improves the knee function. Patella-related complications are associated with its treatment methods, but post-operative anterior knee pain and patient's satisfaction are not related to treatment methods of the patella.
Influence of Total Knee Arthroplasty on Patellar Kinematics and Patellofemoral Pressure.
Tanikawa, Hidenori; Tada, Mitsunori; Harato, Kengo; Okuma, Kazunari; Nagura, Takeo
2017-01-01
Patellofemoral complications are one of the main problems after total knee arthroplasty (TKA). The design of the TKA component may affect the patellar biomechanics, which may be associated with this postoperative complication. The purpose of this study was to assess the influence of TKA and prosthesis designs on the patellar kinematics and patellofemoral pressure. Using fresh-frozen cadavers, we measured the patellofemoral pressure, patella offset, and patella tilt in the following 4 conditions: normal knee (patella replacement only), cruciate-retaining TKA, condylar-stabilizing TKA, and posterior-stabilized TKA. The patellofemoral pressure increased significantly after the cruciate-retaining TKA and condylar-stabilizing TKA compared with the normal knee. The patella offset in the normal knee decreased with increasing knee flexion angles, while the patella offset in the TKA knees did not change significantly through the full range of motion. The amount of lateral patella tilt in the normal knee was significantly larger than the TKA knees in the full range of motion. Although the femoral components are designed to reproduce an anatomical patellar tracking, the physiological patellar kinematics were not observed. Relatively high patellofemoral pressure and kinematic change after TKA may be associated with postoperative complications such as the anterior knee pain. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Smith, Chadwick F.; Johansen, W. Edward; Vangness, C. Thomas; Yamaguchi, Ken; McEleney, Emmett T.; Bales, Peter
1987-03-01
One of the authors has performed 162 arthroscopic laser surgeries in the knee joint without any major complication. Other investigators have recently proposed diagnostic arthroscopy and arthroscopic surgery for "non-knee" joints. The authors have proposed that arthroscopic laser surgery he extended to "non-knee" joints. The authors have performed arthroscopic laser surgery on "non-knee" joints of twelve cadavers. One of the authors have performed one successful arthroscopic surgery on a shoulder joint with only a minor, transient complication of subcutaneous emphysema. Is laser arthroscopic surgery safe and effective in "non-knee" joints? The evolving answer appears to be a qualified "Yes," which needs to be verified by a multicenter trial.
Dislocation of cochlear implant magnet as a complication following MRI.
Murtojärvi, Sarita; Salonen, Jaakko
According to current best knowledge, an MRI scan can be performed for patients with cochlear implants. The warnings and recommendations of the implant manufacturers must be followed strictly to prevent complications, such as overheating, migration or demagnetization of the magnet in the implant. We report on a case of cochlear implant magnet dislocation as a complication for an MRI scan. The patient had a tight bandage around the head to hold the magnet in place as recommended by the manufacturer, but apparently the bandage was not in the correct place.
Acute Hydrocephalus as a Complication of Cervical Spine Fracture and Dislocation: A Case Report
Chung, Yoon Young; Ju, Chang Il; Kim, Dong Min
2014-01-01
Hydrocephalus is a well-known complication of head injury, but an uncommon complication of a spinal lesion. Here, we present a rare case of acute obstructive hydrocephalus secondary to a cervical fracture and dislocation. A 60-year-old female patient was transferred to the emergency department with quadriplegia and respiratory difficulty. Imaging studies showed a cervical fracture and dislocation at the C3-4 level. She required intubation and mechanical ventilation. Twenty-four hours after admission, her mental status had deteriorated and both pupils were dilated. Computed tomography of the brain showed acute hydrocephalus; therefore, extraventricular drainage (EVD) was performed. After the EVD, her mental status recovered and she became alert, but she remained quadriplegic and dependent on the ventilator. Two months after injury, she died because of respiratory failure caused by pneumonia. PMID:25110487
Jia, Di; Li, Yanlin; Wang, Guoliang; Gao, Huanyu; Yu, Yang
2016-01-01
To conclude the revision reason of unicompartmental knee arthroplasty (UKA) using computer-assisted technology so as to provide reference for reducing the revision incidence and improving the level of surgical technique and rehabilitation. The relevant literature on analyzing revision reason of UKA using computer-assisted technology in recent years was extensively reviewed. The revision reasons by computer-assisted technology are fracture of the medial tibial plateau, progressive osteoarthritis of reserved compartment, dislocation of mobile bearing, prosthesis loosening, polyethylene wear, and unexplained persistent pain. Computer-assisted technology can be used to analyze the revision reason of UKA and guide the best operating method and rehabilitation scheme by simulating the operative process and knee joint activities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ritter, M.A.; Keating, E.M.; Faris, P.M.
1989-11-01
Forty-eight patients treated by primary bilateral simultaneous total knee arthroplasty, in which one knee had a lateral release and the other did not, were evaluated clinically and roentgenographically from one to 12 years postoperatively. Thirty of these patients also had a technetium-99 bone scan. Mean clinical scores at the last follow-up examination were 90 for both groups. Roentgenographically, there were no subluxations, dislocations, or fractures in either group. There were two metal-backed patellae (one in each group) with signs of polyethylene wear and developed debris. Bone scans showed no difference between the two groups and no signs of osteonecrosis ofmore » the patella.« less
Kirschner, S; Konrad, T; Weil, E J; Bühler, M
2004-07-01
Arterial complications after total knee arthroplasty are rare. If the formation of a false aneurysm does occur, it usually affects the popliteal artery. We report the case of an 77 year old female with a false aneurysm of the lateral superior genicular artery. The patient was suffering from gonarthrosis and received a duocondylar knee replacement without resurfacing of the patella. Postoperatively, she reported anterior knee pain and a revision of the joint with lateral release was carried out. In the third postoperative week, a painful swelling in the lateral and superior aspect of the knee occurred. A scintigraphic investigation with enrichment in the early period was misinterpreted as infection. Ultrasonographic and angiographic investigations gave the right diagnosis of a false aneurysm. In the same angiographic investigation, the aneurysm could be cured by coil embolisation. The interval between the operation leading to the problem and the formation of the aneurysm, as well as the low incidence of this complication, made it hard to diagnose. Ultrasonographic and angiographic examinations allow for proper diagnosis in cases of unclear painful swellings. When dealing with an arterial complication following total knee arthroplasty, a specialized radiologist or vascular surgeon should be consulted immediately.
Effect of Body Mass Index on Reoperation and Complications After Total Knee Arthroplasty.
Wagner, Eric R; Kamath, Atul F; Fruth, Kristin; Harmsen, William S; Berry, Daniel J
2016-12-21
High body mass index (BMI) is associated with increased rates of complications after total knee arthroplasty. To date, to our knowledge, studies have examined risk as a dichotomous variable using specific BMI thresholds. The purpose of this investigation was to quantify implant survival and the risk of common complications after total knee arthroplasty using BMI as a continuous variable. Using prospectively collected data from our institutional total joint registry, we analyzed 22,289 consecutive knees, in 16,136 patients, treated with primary total knee arthroplasty from 1985 to 2012. The mean BMI of these patients at the time of the surgical procedure was 31.3 kg/m (range, 11 to 69 kg/m). The Kaplan-Meier survival method was used to estimate survivorship, reoperations, and common complications, with associations of outcomes assessed using a Cox regression model. Utilizing smoothing spline parameterization, we found that reoperation (p < 0.001) and implant revision or removal rates (p < 0.001) increased with increasing BMI after total knee arthroplasty. Increasing BMI also was associated with increased rates of wound infection (hazard ratio [HR], 1.07; p < 0.001) and deep infection (HR, 1.08; p < 0.001) per unit of BMI over 35 kg/m. A BMI of 35 to 40 kg/m was associated with a higher rate of implant revision for aseptic loosening (p < 0.001) and for polyethylene wear (p < 0.001) compared with a BMI of 18 to 24.99 kg/m. There was no correlation between BMI and risk of venous thromboembolism, tibiofemoral instability, or need for knee manipulation. The rates of reoperation, implant revision or removal, and many common complications after total knee arthroplasty were strongly associated with BMI. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Knee injuries in women collegiate rugby players.
Levy, A S; Wetzler, M J; Lewars, M; Laughlin, W
1997-01-01
We evaluated the prevalence and patterns of knee injuries in 810 women collegiate rugby players. Injuries that resulted in players missing at least one game were recorded and a questionnaire was used to delineate players' rugby and knee injury history. There were 76 total knee injuries in 58,296 exposures. This resulted in a 1.3 knee injury rate per 1000 exposures. Twenty-one anterior cruciate ligament tears were reported for a 0.36 incidence per 1000 exposures. Other injuries included meniscal tears (25), medical collateral ligament sprains (23), patellar dislocations (5), and posterior cruciate ligament tears (2). Sixty-one percent of the medial collateral ligament sprains occurred in rugby forwards and 67% of anterior cruciate ligament tears occurred in rugby backs. All other injuries occurred with equal frequency in backs and forwards. This study demonstrates that knee injury rates in women's collegiate rugby are similar to those reported for other women's collegiate sports. The overall rate of anterior cruciate ligament injury in women's rugby, however, is slightly higher than that reported for women soccer and basketball players.
Kotwal, Suhel Y; Farid, Yasser R; Patil, Suresh S; Alden, Kris J; Finn, Henry A
2012-02-01
Two-stage reimplantation, with interval antibiotic-impregnated cement spacer, is the preferred treatment of prosthetic knee joint infections. In medically compromised hosts with prior failed surgeries, the outcomes are poor. Articulating spacers in such patients render the knee unstable; static spacers have risks of dislocation and extensor mechanism injury. We examined 58 infected total knee arthroplasties with extensive bone and soft tissue loss, treated with resection arthroplasty and intramedullary tibiofemoral rod and antibiotic-laden cement spacer. Thirty-seven patients underwent delayed reimplantation. Most patients (83.8%) were free from recurrent infection at mean follow-up of 29.4 months. Reinfection occurred in 16.2%, which required debridement. Twenty-one patients with poor operative risks remained with the spacer for 11.4 months. All patients, during spacer phase, had brace-free ambulation with simulated tibiofemoral fusion, without bone loss or loss of limb length. Copyright © 2012 Elsevier Inc. All rights reserved.
Belmont, Philip J; Davey, Shaunette; Orr, Justin D; Ochoa, Leah M; Bader, Julia O; Schoenfeld, Andrew J
2011-09-01
This investigation sought to evaluate risk factors for morbidity and mortality from a large series of below-knee amputees prospectively entered in a national database. All patients undergoing below-knee amputations in the years 2005-2008 were identified in the database of the National Surgical Quality Improvement Program (NSQIP). Demographic data, medical comorbidities, and medical history were obtained. Mortality and postoperative complications within 30 days of the below-knee amputation were also documented. Chi-square test, univariate, and multivariate logistic regression analyses were used to assess the effect of specific risk factors on mortality, as well as the likelihood of developing major, minor, or any complications developing. Below-knee amputations were performed in 2,911 patients registered in the NSQIP database between 2005 and 2008. The average age of patients was 65.8 years old and 64.3% were male. There was a 7.0% 30-day mortality rate and 1,627 complications occurred in 1,013 patients (34.4%). Multivariate logistic regression analysis identified renal insufficiency, cardiac issues, history of sepsis, steroid use, COPD, and increased patient age as independent predictors of mortality. The most common major complications were return to the operating room (15.6%), wound infection (9.3%), and postoperative sepsis (9.3%). History of sepsis, alcohol use, steroid use, cardiac issues, renal insufficiency, and contaminated/infected wounds were independent predictors of one or more complications developing. Renal disease, cardiac issues, history of sepsis, steroid use, COPD, and increased patient age were identified as predictors of mortality after below-knee amputation. Renal disease, cardiac issues, history of sepsis, steroid use, contaminated/infected wounds, and alcohol use were also found to be predictors of postoperative complications. Published by Elsevier Inc.
NASA Technical Reports Server (NTRS)
Neudeck, Philip G.; Huang, Wei; Dudley, Michael
1998-01-01
Given the high density (approx. 10(exp 4)/sq cm) of elementary screw dislocations (Burgers vector = 1c with no hollow core) in commercial SiC wafers and epilayers, all appreciable current (greater than 1 A) SiC power devices will likely contain elementary screw dislocations for the foreseeable future. It is therefore important to ascertain the electrical impact of these defects, particularly in high-field vertical power device topologies where SiC is expected to enable large performance improvements in solid-state high-power systems. This paper compares the DC-measured reverse-breakdown characteristics of low-voltage (less than 250 V) small-area (less than 5 x 10(exp -4)/sq cm) 4H-SiC p(+)n diodes with and without elementary screw dislocations. Compared to screw dislocation-free devices, diodes containing elementary screw dislocations exhibited higher pre-breakdown reverse leakage currents, softer reverse breakdown I-V knees, and highly localized microplasmic breakdown current filaments. The observed localized 4H-SiC breakdown parallels microplasmic breakdowns observed in silicon and other semiconductors, in which space-charge effects limit current conduction through the local microplasma as reverse bias is increased.
NASA Technical Reports Server (NTRS)
Neudeck, Philip G.; Huang, Wei; Dudley, Michael
1999-01-01
Given the high density (approx. 10(exp 4)/sq cm) of elementary screw dislocations (Burgers vector = lc with no hollow core) in commercial SiC wafers and epilayers, all appreciable current (greater than 1 A) SiC power devices will likely contain elementary screw dislocations for the foreseeable future. It is therefore important to ascertain the electrical impact of these defects, particularly in high-field vertical power device topologies where SiC is expected to enable large performance improvements in solid-state high-power systems. This paper compares the DC-measured reverse-breakdown characteristics of low-voltage (less than 250 V) small-area (less than 5 x 10(exp -4) sq cm) 4H-SiC p(+)n diodes with and without elementary screw dislocations. Compared to screw dislocation-free devices, diodes containing elementary screw dislocations exhibited higher pre-breakdown reverse leakage currents, softer reverse breakdown I-V knees, and highly localized microplasmic breakdown current filaments. The observed localized 4H-SiC breakdown parallels microplasmic breakdowns observed in silicon and other semiconductors, in which space-charge effects limit current conduction through the local microplasma as reverse bias is increased.
Engel, Michael; Castrillon-Oberndorfer, Gregor; Hoffmann, Jürgen; Egermann, Marcus; Freudlsperger, Christian; Thiele, Oliver Christian
2012-09-01
This is a survey of the long-term result after various surgical treatments in a child with microcephalic osteodysplastic primordial dwarfism type II (MOPD II) and craniosynostosis. We report a 17-year-old patient with MOPD II but some unusual clinical signs including bilateral knee dislocation, a misplaced upper lobe bronchus, and hypoplasia of the anterior corpus callosum. Because of premature fusion of several cranial sutures, the child developed signs of increased intracranial pressure with somnolence and papilledema. Cranial vault remodeling with fronto-orbital advancement was performed twice at the age of 16 and 21 months to open the abnormally closed suture, increase the intracranial volume, and relieve the elevated intracranial pressure. Following this procedure, the child's neurologic situation recovered significantly. Surgical procedure of fronto-orbital advancement and the performed reoperation in our patient were safe with no major complications intraoperatively and postoperatively with good functional and satisfying aesthetic outcomes in the long-term follow-up, expressed by the patient, his parents, and the surgeons.
Hoggett, L; Cross, C; Helm, T
2017-12-01
Dislocation after total hip arthroplasty (THA) remains a significant complication of the procedure and is the third leading cause for revision THA. One technique for treatment of this complication is the use of the posterior lip augmentation device (PLAD). We describe our experience using the PLAD including complication rates. A retrospective review of 55 PLADs (54 patients) was carried out following identification from electronic theatre records. Basic patient demographics, operative records and radiographs were collected and reviewed and data was analysed using Microsoft Excel. Failure of the PLAD was defined as further operative intervention after PLAD insertion and included: dislocation, implant breakage, infection and revision of the THA for loosening of either component. 55 PLADs were implanted in 54 patients with an average age of 77 years. There was a significant preponderance of females and a variety of surgical approaches had been used for the original hip replacement, including trochanteric osteotomy, posterior and antero-lateral. 9 (16%) patients had recurrent dislocations,1 (2%) failed secondary to screw breakage, 3 (5%) had and infection requiring intervention and 2 (4%) underwent further revision for aseptic loosening of the femoral component. The overall failure rate was 25% with 14 patients requiring intervention post PLAD. Our results are inferior to other published results and indicate that the PLAD should be used with caution for recurrent dislocations of the Charnley hip replacement.
Shin, Sang-Jin; Kim, Nam-Ki
2015-05-01
The purpose of this study was to evaluate clinical and radiological outcomes after arthroscopically assisted coracoclavicular (CC) fixation using a single adjustable-loop-length suspensory fixation device for acute acromioclavicular dislocation and to report intraoperative and postoperative complications. Eighteen consecutive patients with acute acromioclavicular dislocation underwent arthroscopically assisted CC fixation using a single TightRope (Arthrex, Naples, FL). Using the Rockwood classification, 3 patients had grade III dislocations, one patient had a grade IV dislocation, and 14 patients had grade V dislocations. The preoperative CC distance of the injured shoulder was 16.1 ± 2.7 mm (range, 11.2 to 21.0 mm), and it increased by 99% ± 36% (range, 17% to 153%) on average compared with the contralateral shoulder. The average CC distance was 10.5 ± 2.5 mm (range, 7.7 to 15.5 mm), and it increased by 30% ± 30% (range, -9.4% to 90%) at the final follow-up. Compared with immediate postoperative radiographs, the CC distance was maintained in 12 patients, increased between 50% and 100% in 4 patients, and increased more than 100% in 2 patients at final follow-up. However, there was no statistical difference in Constant scores between 6 patients with reduction loss (95.6 ± 4.5) and 12 patients with reduction maintenance (98.4 ± 2.5; P = .17). Perioperative complications occurred in 8 patients, including one case of acromioclavicular arthritis, one case of delayed distal clavicular fracture at the clavicular hole of the device, 3 cases of clavicular or coracoid button failures, and 3 cases of clavicular bony erosion. Satisfactory clinical outcomes were obtained after CC fixation using the single adjustable-loop-length suspensory fixation device for acute acromioclavicular joint dislocation. However, CC fixation failure of greater than 50% of the unaffected side in radiological examinations occurred in 33% of the patients within 3 months after the operation. Additionally, 8 patients (44%) had complications associated with the adjustable-loop-length suspensory fixation device and surgical technical problems. Despite acceptable shoulder function restoration, adequate care should be exercised in surgical treatment of acute acromioclavicular dislocation with a single adjustable-loop-length suspensory fixation device for optimal radiological outcomes. Level IV, therapeutic case series. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Degreef, I; De Smet, L
2007-06-01
A case is presented of chronic dislocation of the elbow after tennis elbow surgery combined with posterior interosseous nerve (PIN) release. An open reduction with repair of the collateral ligaments was performed. Postoperative rehabilitation involved the use of an articulated external fixator and there was a successful outcome. Possible causes of the dislocation are discussed.
Gaździk, Tadeusz Szymon; Kotas-Strzoda, Justyna; Bozek, Marek
2004-01-01
Knee arthrodesis is the method of choice in treatment of failed total knee replacement. It is recommended when revisory total knee replacement is impossible. The authors present 2 cases of knee fusions using intramedullary nails after prosthesis loosening (1 aseptic, 1 septic). In both cases good results were achieved, with no complications observed during convalescence.
Sharma, Tankamani; Hönle, Wolfgang; Handschu, René; Adler, Werner; Goyal, Tarun; Schuh, Alexander
2018-06-01
The aim of this study is to evaluate the difference in perioperative complication rate in total hip, bipolar hemiarthroplasties and total knee arthroplasty in patients with Parkinson disease in trauma and elective surgery in our Musculoskeletal Center during a period of 10 years. Between 2006 and 2016, 45 bipolar hemiarthroplasties in trauma surgery, 15 total knee and 19 total hip arthroplasties in patients with Parkinson's disease were performed. We divided the patients in two groups. Group I included trauma cases (45) and group II elective surgery cases (34). Complications were documented and divided into local minor and major complications and general minor and major complications. Fisher's exact test was used for statistical evaluation. In both groups, there was one local major complication (p > 0.05): In group I, there was one case of loosening of a K-wire which was removed operatively. In group II, there was one severe intraarticular bleeding requiring puncture of the hematoma. In group I, there were 38 general complications; in group II, there were 17 general complications. There was no statistical difference in complication rate (p > 0.05). Total hip arthroplasty, bipolar hemiarthroplasties and knee arthroplasty in patients with Parkinson disease is possible in elective and trauma surgery. Complication rate is higher in comparison with patients not suffering from Parkinson disease, but there is no difference in complication rate in elective and trauma surgery. Nevertheless, early perioperative neurological consultation in patients with Parkinson disease is recommended to minimize complications and improve early outcomes after arthroplasty.
Bodendorfer, Blake M; Keeling, Laura E; Michaelson, Evan M; Shu, Henry T; Apseloff, Nicholas A; Spratt, James D; Malone, Patrick S; Argintar, Evan H
2018-05-31
Arthrofibrosis can be a devastating complication after ligamentous knee reconstruction. Beyond early range of motion (ROM), manipulation under anesthesia (MUA) and arthroscopic lysis of adhesions (LOAs) are the most frequently employed interventions for the condition. There is a paucity of data regarding predictive factors of arthrofibrosis requiring MUA and LOA, and even less data regarding changes in validated patient-reported outcome measures following the procedure. A retrospective case-control study was performed at an academic, urban Level I trauma center of patients that developed arthrofibrosis requiring MUA and LOA following ligamentous reconstruction. The indication for LOA was failure to achieve a 90° arc of ROM by 6 weeks. Seventeen cases and 141 controls were identified. Follow-up for cases was 26.9 ± 17.1 months (mean ± standard deviation). Time from initial reconstruction to LOA was 75.2 ± 27.9 days. Cases had higher body mass indices by a mean of 2.9 ( p = 0.024). The most significant risk factors for stiffness were concomitant anterior cruciate ligament, posterior cruciate ligament, and posterolateral corner/lateral collateral ligament injury (odds ratio [OR], 17.08), knee dislocation (OR, 12.84), and use of an external fixator (OR, 12.81, 95% confidence interval [CI], 3.03-54.20) (all p < 0.0026). Mean Knee Injury and Osteoarthritis Outcome Scores, Western Ontario and McMaster Universities Osteoarthritis Indices, and International Knee Documentation Committee scores improved by 47.5, 50.5, and 47.3% (all p < 0.0038), respectively. All patients reported improvement in pain, with maximum daily pain scores improving by a mean of 4.1 points on the Numeric Pain Rating Scale ( p < 0.001). Mean ROM arc improved by 38.8° ( p < 0.001). All 17 cases were satisfied with the procedure. Twelve cases (70.59%) reported a full return to preinjury level of activity. No factors were identified that predicted success from the procedure, likely due to inadequate sample size. Arthrofibrosis following knee injury and ligamentous reconstruction can be predicted by the severity of injury and early intervention with MUA and arthroscopic LOA can lead to a satisfactory outcome for the patient. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Wichita fusion nail for patients with failed total knee arthroplasty and active infection.
Barsoum, Wael K; Hogg, Christopher; Krebs, Viktor; Klika, Alison K
2008-01-01
In the study reported here, we retrospectively evaluated short-term results of knee arthrodesis using the Wichita fusion nail (WFN) in patients with active infection. Clinical examinations, x-rays, time to union, knee pain after fusion, and ambulatory status were compared in 7 patients who received the WFN. Mean fusion rate was 86%, mean time to fusion was 9.8 months, and mean complication rate was 57%. Complication rates were high, but clinical outcomes were acceptable, supporting use of WFN as a reasonable way to salvage failed total knee arthroplasty in patients with active infection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kickuth, Ralph, E-mail: ralph.kickuth@insel.ch; Anderson, Suzanne; Peter-Salonen, Kristiina
2006-12-15
Joint hemorrhages are very common in patients with severe hemophilia. Inhibitors in patients with hemophilia are allo-antibodies that neutralize the activity of the clotting factor. After total knee replacement, rare intra-articular bleeding complications might occur that do not respond to clotting factor replacement. We report a 40-year-old male with severe hemophilia A and high responding inhibitors presenting with recurrent knee joint hemorrhage after bilateral knee prosthetic surgery despite adequate clotting factor treatment. There were two episodes of marked postoperative hemarthrosis requiring extensive use of subsititution therapy. Eleven days postoperatively, there was further hemorrhage into the right knee. Digital subtraction angiographymore » diagnosed a complicating pseudoaneurysm of the inferior lateral geniculate artery and embolization was successfully performed. Because clotting factor replacement therapy has proved to be excessively expensive and prolonged, especially in patients with inhibitors, we recommend the use of cost-effective early angiographic embolization.« less
Is Obesity a Risk Factor for Adverse Events After Knee Arthroscopy?
Sing, David C; Luan, Tammy F; Feeley, Brian T; Zhang, Alan L
2016-07-01
To evaluate how body mass index (BMI) affects rates of 30-day complication, hospital readmissions, and mortality in patients undergoing knee arthroscopy. Patients undergoing knee arthroscopy procedures between 2006 and 2013 were identified in the American College of Surgeons National Surgical Quality Improvement Program database. Patient demographics and preoperative risk factors including BMI were analyzed for postoperative complications within 30 days. Cochran-Armitage testing was performed to detect differences in complication rates across BMI categories according to World Health Organization classification. The independent risk of BMI was assessed using multivariate regression analysis. Of 41,919 patients with mean age 48 years undergoing knee arthroscopy, 20% were classified as normal weight (BMI 18.5 to 24), 35% overweight (BMI 25 to 29), 24% obese class I (BMI 30 to 34), 12% class II (BMI 35 to 40), and 9% class III (BMI ≥40). Risk of complication increased significantly with increasing BMI (normal: 1.5%, overweight: 1.6%, obese class I: 1.7%, obese class II: 1.8%, obese class III: 1.9%, P = .043). On multivariate analysis, there was no increased risk of postoperative complication directly attributed to patient BMI. Independent risk factors for medical and surgical complications after knee arthroscopy included American Society of Anesthesiologists (ASA) rating (class 4 v class 1 odds ratio [OR]: 5.39 [95% confidence interval: 3.11-9.33], P < .001), functional status for activities of daily living (dependent v independent OR: 2.13 [1.42, 3.31], P < .001), history of renal comorbidity (presence v absence OR: 5.10 [2.30, 11.29], P < .001), and previously experienced history of wound infection prior to current surgery (presence v absence OR: 4.91 [2.88, 8.39], P < .001). More than 40% of knee arthroscopy patients qualify as obese. Although univariate analysis suggests that obesity is associated with increased postoperative complications within 30 days of surgery, BMI alone does not predict complications. Independent predictors of complications include patients with high ASA classification, dependent functional status, renal comorbidities, and a recent history of wound infection. Level IV, prognostic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Neudeck, Philip G.; Huang, Wei; Dudley, Michael; Fazi, Christian
1998-01-01
It is well-known that SiC wafer quality deficiencies are delaying the realization of outstandingly superior 4H-SiC power electronics. While efforts to date have centered on eradicating micropipes (i.e., hollow core super-screw dislocations with Burgers vectors greater than or equal to 2c), 4H-SiC wafers and epilayers also contain elementary screw dislocations (i.e., Burgers vector = 1c with no hollow core) in densities on the order of thousands per sq cm, nearly 100-fold micropipe densities. While not nearly as detrimental to SiC device performance as micropipes, it has recently been demonstrated that elementary screw dislocations somewhat degrade the reverse leakage and breakdown properties of 4H-SiC p(+)n diodes. Diodes containing elementary screw dislocations exhibited a 5% to 35% reduction in breakdown voltage, higher pre-breakdown reverse leakage current, softer reverse breakdown I-V knee, and microplasmic breakdown current filaments that were non-catastrophic as measured under high series resistance biasing. This paper details continuing experimental and theoretical investigations into the electrical properties of 4H-SiC elementary screw dislocations. The nonuniform breakdown behavior of 4H-SiC p'n junctions containing elementary screw dislocations exhibits interesting physical parallels with nonuniform breakdown phenomena previously observed in other semiconductor materials. Based upon experimentally observed dislocation-assisted breakdown, a re-assessment of well-known physical models relating power device reliability to junction breakdown has been undertaken for 4H-SiC. The potential impact of these elementary screw dislocation defects on the performance and reliability of various 4H-SiC device technologies being developed for high-power applications will be discussed.
Descending genicular artery injury following transient lateral patellar dislocation.
Silvestri, Andrea; Regis, Dario; Trivellin, Giacomo; Piccoli, Marco; Spina, Mauro; Magnan, Bruno; Sandri, Andrea
2018-06-01
Transient lateral patellar dislocation (TLPD) is a common lesion in young adults. Vascular injury as a complication of TLPD has not been previously described. We report a case of descending genicular artery (DGA) injury after TLPD. Immediate angiography demonstrated rupture of DGA. Embolization was performed with sudden interruption of bleeding. DGA injury should be considered as a complication after TLPD and prompt diagnosis and intervention are required. We propose selective embolization as a safe and effective procedure to stop bleeding.
Niimoto, Takuya; Deie, Masataka; Adachi, Nobuo; Usman, Muhammad Andry; Ochi, Mitsuo
2014-10-01
The aims of the present controlled clinical study were to (1) compare patella laxity determined in the outpatient clinic with that in anaesthetized patients and (2) evaluate patella laxity before and after lateral release. The study evaluated data on 33 knees from 33 patients (average age 19.7 years) between 2007 and 2011. All patients were diagnosed with recurrent dislocation of the patella. Patellar stability was evaluated in each patient thrice: patellas were first imaged in the outpatient clinic prior to surgery at 45° knee flexion with 20 N stress from the medial to lateral side and from the lateral to medial side; then, at the time of surgery, patella stress images were obtained in the same manner before and after the lateral release procedure. Radiological assessments were performed using the medial stress shift ratio (MSSR) and lateral stress shift ratio (LSSR). There were no significant differences in the LSSR and MSSR before surgery (outpatient data) and in anaesthetized patients before the lateral release procedure. Furthermore, there was no significant difference in MSSR at the time of surgery before and after the lateral release procedure. However, LSSR increased significantly after the lateral release procedure. The results of the present study suggest that quantitative patella stress radiography in the outpatient clinic is useful when it comes to investigating laxity of the patella, and that lateral release significantly increases lateral, but not medial, laxity in patients with recurrent patellar dislocation. IV.
Hermanns, Pia; Unger, Sheila; Rossi, Antonio; Perez-Aytes, Antonio; Cortina, Hector; Bonafé, Luisa; Boccone, Loredana; Setzu, Valeria; Dutoit, Michel; Sangiorgi, Luca; Pecora, Fabio; Reicherter, Kerstin; Nishimura, Gen; Spranger, Jürgen; Zabel, Bernhard; Superti-Furga, Andrea
2008-06-01
Deficiency of carbohydrate sulfotransferase 3 (CHST3; also known as chondroitin-6-sulfotransferase) has been reported in a single kindred so far and in association with a phenotype of severe chondrodysplasia with progressive spinal involvement. We report eight CHST3 mutations in six unrelated individuals who presented at birth with congenital joint dislocations. These patients had been given a diagnosis of either Larsen syndrome (three individuals) or humero-spinal dysostosis (three individuals), and their clinical features included congenital dislocation of the knees, elbow joint dysplasia with subluxation and limited extension, hip dysplasia or dislocation, clubfoot, short stature, and kyphoscoliosis developing in late childhood. Analysis of chondroitin sulfate proteoglycans in dermal fibroblasts showed markedly decreased 6-O-sulfation but enhanced 4-O-sulfation, confirming functional impairment of CHST3 and distinguishing them from diastrophic dysplasia sulphate transporter (DTDST)-deficient cells. These observations provide a molecular basis for recessive Larsen syndrome and indicate that recessive Larsen syndrome, humero-spinal dysostosis, and spondyloepiphyseal dysplasia Omani type form a phenotypic spectrum.
Misfit dislocation patterns of Mg-Nb interfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Youxing; Shao, Shuai; Liu, Xiang-Yang
The role of heterogeneous interfaces in improving mechanical properties of polycrystalline aggregates and laminated composites has been well recognized with interface structure being of fundamental importance in designing composites containing multiple interfaces. In this paper, taking the Mg (hexagonal close-packed (hcp))/Nb (body-centered cubic (bcc)) interface as an example, we develop Mg-Nb interatomic potentials for predicting atomic configurations of Mg/Nb interfaces. We systematically characterize interface dislocations of Mg/Nb interfaces with Nishiyama-Wassermann (NW) and Kurdjumov-Sachs (KS) orientation relationships and propose a generalized procedure of characterizing interface structure by combining atomistic simulation and interface dislocation theory, which is applicable for not only hcp/bccmore » interfaces, but also other systems with complicated interface dislocation configurations.Here, in Mg/Nb, interface dislocation networks of two types of interfaces are significantly different although they originate from partial dislocations of similar character: the NW interface is composed of three sets of partial dislocations, while the KS interface is composed of four sets of interface dislocations - three sets of partial dislocations and one set of full dislocations that forms from the reaction of two close partial dislocations.« less
1997 Accession Medical Standards Analysis & Research Activity (AMSARA) Annual Report
1998-05-01
3.7 Hip Dental 13 2.8 Hip dislocation 44 2.1 Injury-lower 11 2.4 Foot-ankle 41 1.9 extremities Prior knee surgery .7 1.5 Curvature of the spine 35...Genetic Influences in Childhood-Onset Psychiatric Disorders: Autism and Attention-Deficit/Hyperactivity Disorder. Am J Hum Genet 1997;60:1276-1282
Davies, Simon R
2011-03-01
Vertebral artery damage after cervical fracture and especially cervical dislocations is a recognized phenomenon. The incidence of significant intracranial neurology after unilateral vertebral damage is extremely rare, and to our knowledge, no such injury has been sustained while playing sport. To describe a rare vascular complication of a bifacet C5-C6 dislocation. Case report and clinical discussion. We present a 28-year old white man who was a professional rugby player. He sustained a hyperflexion injury while playing scrum half in a recent league match, which resulted in a C5-C6 dislocation, diagnosed clinically and with a plain radiograph. The patient on admission had complete neurologic loss below C6. The patient underwent immediate computed tomography and magnetic resonance imaging (MRI) scans that revealed a 50% displacement of C5 on C6 with a complete unifacet dislocation and the other facet partially dislocated. The MRI revealed signal changes in the cord at the C5-C6 level and an intimal tear in the left vertebral artery. The decision was taken to reduce the dislocation when medically stable. A few hours after injury, after an episode of vomiting, the patient sustained a respiratory arrest owing to the embolization of a clot from the left vertebral artery into the basilar artery. Despite rapid embolectomy and subsequent permanent left vertebral artery occlusion, the patient sustained multiple infarcts in the cerebellar, thalamic, occipital, and pontine regions of the brain that eventually proved fatal. This case shows a rare complication of unilateral vertebral artery occlusion. Despite early identification of a basilar infarct and a successful embolectomy, intracranial infarction occurred. Although there is no guideline for the treatment of vertebral artery damage, early reduction and anticoagulation may reduce the risk of cerebral infarction. Copyright © 2011 Elsevier Inc. All rights reserved.
Kuikka, P-I; Pihlajamäki, H K; Mattila, V M
2013-06-01
The population-based incidence and risk factors for knee injuries in young adults were assessed in Finnish male conscripts performing their compulsory military service (n = 128,584). The main outcome variables were (1) hospitalization due to knee injuries overall and (2) hospitalization due to knee disorders as categorized into specific International Classification of Diseases, tenth revision diagnoses (cruciate and collateral ligament tears, meniscal tears, traumatic chondral lesions, and patellar dislocations). Person-time injury-incidence rates were calculated by dividing the number of persons with a diagnosed knee injury by the total exposure time of 97,503 person-years. The number of subjects with surgical operations and military service class changes indicative of longer term notable disability are also reported. Risk factor analyses were performed by logistic regression. The person-based incidence of hospitalizations for knee injury was 11 cases per 1000 person-years [95% confidence interval (CI): 10.4-11.7]. The most important risk factors were higher age (odds ratio 1.7; 95% CI: 1.3-2.2) and obesity (odds ratio 1.6; 95% CI: 1.03-2.5). Two thirds of all subjects hospitalized for knee injuries had surgery, and one third had longer term notable disability. These findings indicate that knee injuries cause a significant burden of hospitalizations, often leading to surgery and longer term disability. © 2011 John Wiley & Sons A/S.
Comparison of Alignment Correction Angles Between Fixed-Bearing and Mobile-Bearing UKA.
Inoue, Atsuo; Arai, Yuji; Nakagawa, Shuji; Inoue, Hiroaki; Yamazoe, Shoichi; Kubo, Toshikazu
2016-01-01
Good outcomes have been reported with both fixed-bearing and mobile-bearing unicompartmental knee arthroplasty (UKA). However, overcorrected alignment could induce the progression of arthritis on the non-arthroplasty side. Changes of limb alignment after UKA with both types of bearings (fixed bearing: 24 knees, mobile bearing: 28 knees) were investigated. The mean difference between the preoperative standing femoral-tibial angle (FTA) and postoperative standing FTA was significantly larger in mobile bearing UKA group. In fixed-bearing UKA, there must be some laxity in MCL tension so that a 2-mm tension gauge can be inserted. In mobile-bearing UKA, appropriate MCL tension is needed to prevent bearing dislocation. This difference in MCL tension may have caused the difference in the correction angle between the groups. Copyright © 2016 Elsevier Inc. All rights reserved.
Dural ectasia in a child with Larsen syndrome.
Jain, Viral V; Anadio, Jennifer M; Chan, Gilbert; Sturm, Peter F; Crawford, Alvin H
2014-01-01
We present a case of an incidental finding of dural ectasia in a child diagnosed with Larsen syndrome. Larsen syndrome is a rare inherited disorder of connective tissue characterized by facial dysmorphism, congenital joint dislocations of the hips, knees and elbows, and deformities of the hands and feet. Dural ectasia is as an abnormal expansion of the dural sac surrounding the spinal cord and may result in spinal morphologic changes, instability, and spontaneous dislocation. To the best of our knowledge, the presence of dural ectasia in Larsen syndrome has not previously been reported. A 6-year-old boy diagnosed with Larsen syndrome presented with an upper thoracic curve measuring 74 degrees, a right thoracic curve measuring 65 degrees, and significant cervicothoracic kyphosis with 50% anterior subluxation of C6 on C7 and C7 on T1. Advanced imaging studies showed dural ectasia (evidenced by spinal canal and dural sac expansion), thinning of pedicles and lamina, and C4 and C6 pars defects with cervical foramen enlargement. The patient received growing rod instrumentation (attached to cervical spine fixation) by a combined anterior/posterior surgical approach using intraoperative halo. Complications included intraoperative medial breach (fully resolved), wound dehiscence, 2 instances of bilateral broken rods, and a broken cervical rod. Following 7 lengthening procedures, the patient underwent definitive fusion. Surgeons should be aware of the potential for dural ectasia in patients with Larsen syndrome. Its presence will cause difficulties in the surgical intervention for spinal deformity. Multiple factors must be considered, and surgical approach and technique will require modification to avoid complications. Although dural ectasia confounds surgical intervention in these patients, surgery still appears to outweigh the risks associated with delayed intervention. The presence of dural ectasia should not preclude surgical decompression and stabilization. This report adds to the body of knowledge on the treatment of Larsen syndrome by demonstrating the potential existence of dural ectasia and highlights the importance of careful and thorough preoperative evaluation and diagnostic imaging.
Lee, Dae-Hee; Jeong, Woong-Kyo; Inna, Prashanth; Noh, Won; Lee, Dong-Ki; Lee, Soon-Hyuck
2011-12-01
Pediatric sacroiliac joint injuries are uncommon. Significant pelvis ring disruptions in children are rare, and their management is complicated by patient size, differences in bony architecture, and future growth and remodeling potential. We present a rare case of anterior sacroiliac joint dislocation associated with triradiate cartilage injury with a posterior sacroiliac dislocation on the contralateral side. This appears to be the first such case reported in the literature.
Bilateral temporomandibular joint dislocation with locked mandibular impaction.
Hynes, Sally L; Jansen, Leigh A; Brown, D Ross; Courtemanche, Douglas J; Boyle, James C
2012-02-01
Bilateral anterior temporomandibular joint dislocation is very rare, with only 2 reported cases published. In the present report, we describe a healthy 25-year-old man from Haida Gwaii, in British Columbia, Canada, who was transferred to our tertiary trauma center with life-threatening complications of a bilateral anterior temporomandibular joint dislocation with locked mandibular impaction. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Infected total knee arthroplasty treated with arthrodesis using a modular nail.
Waldman, B J; Mont, M A; Payman, K R; Freiberg, A A; Windsor, R E; Sculco, T P; Hungerford, D S
1999-10-01
Failed treatment of infected total knee replacement presents few attractive surgical options. Knee arthrodesis is challenging surgically and can be complicated by nonunion, malunion, or recurrent infection. Recently, a modular titanium intramedullary nail has been used in an attempt to reduce the incidence of nonunion and the rate of complications. In the present study, a review of the results of knee arthrodesis after infected total knee arthroplasty in 21 patients at three large academic institutions was performed. All patients were followed up for a mean of 2.4 years (range, 2-7.5 years). The mean age of the patients was 64 years. The mean number of previous operations was four (range, 2-9 operations). A solid arthrodesis was achieved without additional surgical treatment in 20 of 21 patients (95%). The mean time to fusion was 6.3 months. The one patient who suffered a nonunion achieved fusion after a subsequent bone grafting procedure. Based on the present study, intramedullary arthrodesis with a coupled titanium nail, is a reliable, effective method of achieving fusion after infection of a total knee arthroplasty. This procedure resulted in a high rate of fusion and a lower rate of complications when compared with traditional methods of arthrodesis.
Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik
2017-10-01
The purpose of this study was to compare the long-term clinical results, radiographic results, range of knee motion, patient satisfaction, and the survival rate of Medial-Pivot posterior cruciate-substituting, knee prosthesis and a press-fit condylar (PFC) Sigma cruciate-retaining mobile-bearing knee prosthesis in the same patients. One hundred eighty-two patients received Medial-Pivot knee prosthesis in one knee and a PFC Sigma knee prosthesis in the contralateral knee. The minimum duration of follow-up was 11 years (range, 11-12.6 years). The knees with a Medial-Pivot knee prosthesis had significantly worse results than those with a PFC Sigma knee prosthesis at the final follow-up with regard to the mean postoperative Knee Society knee scores (90 compared with 95 points), Western Ontario and McMaster Universities Osteoarthritis Index score (25 compared with 18 points), and range of knee motion (117° compared with 128°). Patients were more satisfied with PFC Sigma knee prosthesis (93%) than with Medial-Pivot knee prosthesis (75%). Complication rates were significantly higher in the Medial-Pivot knee group (26%) than those in the PFC Sigma knee group (6.5%). Radiographic results and survival rates (99% compared with 99.5%) were similar between the 2 groups. Although the long-term fixation and survival rate of both Medial-Pivot and PFC Sigma prostheses were similar, we observed a worse knee score, worse range of knee motion, and patient satisfaction was less in the Medial-Pivot knee group than in the PFC Sigma knee group. Furthermore, complication rate was also higher in the Medial-Pivot knee group than the other group. Copyright © 2017 Elsevier Inc. All rights reserved.
Liu, Guisen; Cheng, Xi; Wang, Jian; Chen, Kaiguo; Shen, Yao
2017-01-01
Prediction of Peierls stress associated with dislocation glide is of fundamental concern in understanding and designing the plasticity and mechanical properties of crystalline materials. Here, we develop a nonlocal semi-discrete variational Peierls-Nabarro (SVPN) model by incorporating the nonlocal atomic interactions into the semi-discrete variational Peierls framework. The nonlocal kernel is simplified by limiting the nonlocal atomic interaction in the nearest neighbor region, and the nonlocal coefficient is directly computed from the dislocation core structure. Our model is capable of accurately predicting the displacement profile, and the Peierls stress, of planar-extended core dislocations in face-centered cubic structures. Our model could be extended to study more complicated planar-extended core dislocations, such as <110> {111} dislocations in Al-based and Ti-based intermetallic compounds. PMID:28252102
Tan, Lei; Li, Yan-Hui; Sun, Da-Hui; Zhu, Dong; Ning, Shu-Yan
2015-01-01
Objective: There is currently no general consensus on the optimal treatment of chronic radial head dislocation. Material and Methods: Considering that the annular ligament is important in maintaining elbow stability, we developed a modified method for annular ligament reconstruction in pediatric cases of radial head dislocation without ulnar bowing. We retrospectively investigated the therapeutic outcomes of this technique in a series of cases. We used our modified technique for the treatment of five patients between January 2006 and January 2012. The average age of the patients at the time of injury was 9 years (range, 6-14 years), and the patients were followed up for 1 to 3 years. Results: The perioperative and follow-up data of the patients were examined. All five surgical procedures were completed uneventfully and had been tolerated well by the patients, with minimal complications. Remarkable improvement was noted in all the cases at the end of the follow-up period. Conclusions: Our modified technique for annular ligament reconstruction was effective in achieving good reduction of the radial head dislocation with minimal complications in pediatric cases of isolated radial head dislocation without apparent ulnar bowing. PMID:26770420
Scuderi, Giles R; Hedden, David R; Maltry, John A; Traina, Steven M; Sheinkop, Mitchell B; Hartzband, Mark A
2012-03-01
Between May 2001 and June 2004, 388 total knee arthroplasty cases were enrolled in a prospective, randomized, multicenter investigational device exemption trial. Patients received either the investigational high-flexion mobile-bearing knee or a fixed-bearing control. At 2 to 4 years of follow-up, results in 293 patients with degenerative joint disease were compared using Knee Society Assessment and Function scores, radiographic results, complications analysis, and survival estimates. The mobile-bearing and fixed-bearing groups demonstrated similar, significant improvement over preoperative assessments in Knee Scores, maximum flexion, and range of motion. One mobile-bearing arthroplasty required revision. Radiographic results were unremarkable, and implant-related complications were rare in both groups. At this early follow-up, the investigational high-flexion mobile-bearing knee and its fixed-bearing counterpart demonstrated comparable, effective performance. Copyright © 2012 Elsevier Inc. All rights reserved.
Lawrey, Emma; Jones, Peter; Mitchell, Robin
2012-04-01
Prosthetic hip dislocation is common. This study compares prosthetic hip relocations attempted within the ED by emergency doctors and those under orthopaedic care in the ED or operating theatre (OT). Retrospective cohort study of patients presenting to Auckland City Hospital Adult Emergency Department with prosthetic hip dislocations between 1 January 2003 and 14 April 2008. Primary outcomes were proportion of successful relocation attempts and length of hospital stay. Secondary outcomes were: time to relocation, complications, post-procedural advice, representation rate and long-term outcomes for first-time dislocations. There were 410 eligible presentations during the study period. Emergency medicine (EM) was successful in 254/323 attempts (79%, 95% confidence interval [CI] 74-83). Orthopaedics were successful in 25/35 reductions in the ED (71%, 95% CI 55-84) and 49/51 OT attempts (96%, 95% CI 86-100), P = 0.004 for location OT versus ED. Median times to discharge were 8.8 h for EM, 28.3 h for orthopaedics in the ED and 81 h for orthopaedics in the OT, P < 0.001 for EM versus orthopaedics. Mechanical complications of procedures and early redislocations were infrequent. Complication of sedation were more often seen in OT compared to ED (23/47 [49%, 95% CI 35-63]vs 37/318 [12%, 95% CI 9-16]). There was no difference between EM and orthopaedics in the proportion of hips successfully relocated or complications in the ED; however, EM patients were discharged much sooner, with important resource implications. Procedures carried out in the OT were more successful than in the ED but resulted in prolonged hospital stays and were associated with more complications. © 2012 The Authors. EMA © 2012 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Arthroscopic-assisted Arthrodesis of the Knee Joint With the Ilizarov Technique
Waszczykowski, Michal; Niedzielski, Kryspin; Radek, Maciej; Fabis, Jaroslaw
2016-01-01
Abstract Arthrodesis of the knee joint is a mainly a salvage surgical procedure performed in cases of infected total knee arthroplasty, tumor, failed knee arthroplasty or posttraumatic complication. The authors report the case of 18-year-old male with posttraumatic complication of left knee because of motorbike accident 1 year before. He was treated immediately after the injury in the local Department of Orthopaedics and Traumatology. The examination in the day of admission to our department revealed deformation of the left knee, massive scar tissue adhesions to the proximal tibial bone and multidirectional instability of the knee. The plain radiographs showed complete lack of lateral compartment of the knee joint and patella. The patient complained of severe instability and pain of the knee and a consecutive loss of supporting function of his left limb. The authors decided to perform an arthroscopic-assisted fusion of the knee with Ilizarov external fixator because of massive scar tissue in the knee region and the prior knee infection. In the final follow-up after 54 months a complete bone fusion, good functional and clinical outcome were obtained. This case provides a significant contribution to the development and application of low-invasive techniques in large and extensive surgical procedures in orthopedics and traumatology. Moreover, in this case fixation of knee joint was crucial for providing good conditions for the regeneration of damaged peroneal nerve. PMID:26817899
Waszczykowski, Michal; Niedzielski, Kryspin; Radek, Maciej; Fabis, Jaroslaw
2016-01-01
Arthrodesis of the knee joint is a mainly a salvage surgical procedure performed in cases of infected total knee arthroplasty, tumor, failed knee arthroplasty or posttraumatic complication.The authors report the case of 18-year-old male with posttraumatic complication of left knee because of motorbike accident 1 year before. He was treated immediately after the injury in the local Department of Orthopaedics and Traumatology. The examination in the day of admission to our department revealed deformation of the left knee, massive scar tissue adhesions to the proximal tibial bone and multidirectional instability of the knee. The plain radiographs showed complete lack of lateral compartment of the knee joint and patella. The patient complained of severe instability and pain of the knee and a consecutive loss of supporting function of his left limb. The authors decided to perform an arthroscopic-assisted fusion of the knee with Ilizarov external fixator because of massive scar tissue in the knee region and the prior knee infection.In the final follow-up after 54 months a complete bone fusion, good functional and clinical outcome were obtained.This case provides a significant contribution to the development and application of low-invasive techniques in large and extensive surgical procedures in orthopedics and traumatology. Moreover, in this case fixation of knee joint was crucial for providing good conditions for the regeneration of damaged peroneal nerve.
Helito, Camilo Partezani; Junqueira, Jader Joel Machado; Gobbi, Ricardo Gomes; Angelini, Fábio Janson; Rezende, Marcia Uchoa; Tírico, Luis Eduardo Passarelli; Demange, Marco Kawamura; da Mota e Albuquerque, Roberto Freire; Pécora, José Ricardo; Camanho, Gilberto Luis
2014-01-01
OBJECTIVES: Healing is an event that is fundamental to the success of total knee arthroplasty. The aims of the present study were to compare the rates of complications related to wound healing between two groups of volunteers submitted to total knee arthroplasty and to evaluate the effects of postoperative oxygen supplementation by means of a nasal catheter. METHOD: A total of 109 patients who underwent total knee arthroplasty were randomized into two groups, namely, groups that did and did not receive postoperative oxygen supplementation via a nasal catheter. The surgical wound was monitored every day during the hospital stay and on the 7th, 14th, 21st, 30th and 42nd postoperative days. Characteristics related to healing were observed, including hyperemia, dehiscence, necrosis, phlyctenules and deep and superficial infection. RESULTS: There were no cases of deep infection. Hyperemia was statistically correlated with the total number of complications in the groups, with oxygen demonstrated to be a protective factor against hyperemia. Approximately 30% of the patients who exhibited hyperemia had other complications, independent of oxygen supplementation. CONCLUSION: Oxygen supplementation following total knee arthroplasty was shown to be effective in diminishing hyperemia around the operative wound. The development of hyperemia was a precursor to other complications, irrespective of whether oxygen supplementation was used. PMID:25518030
Arliani, Gustavo Gonçalves; Utino, Artur Yudi; Nishimura, Eduardo Misao; Terra, Bernardo Barcellos; Belangero, Paulo Santoro; Astur, Diego Costa
2015-01-01
Objective To evaluate the approaches and procedures used by Brazilian orthopedic surgeons in treatment and rehabilitation of acromioclavicular dislocation of the shoulder. Methods A questionnaire comprising eight closed questions that addressed topics relating to treatment and rehabilitation of acromioclavicular dislocation was applied to Brazilian orthopedic surgeons over the three days of the 45th Brazilian Congress of Orthopedics and Traumatology, in 2013. Results A total of 122 surgeons completely filled out the questionnaire and formed part of the sample analyzed. Most of them came from the southeastern region of the country. In this sample, 67% of the participants would choose surgical treatment for patients with grade 3 acromioclavicular dislocation. Regarding the preferred technique for surgical treatment of acute acromioclavicular dislocation, a majority of the surgeons used subcoracoid ligature with acromioclavicular fixation and transfer of the coracoacromial ligament (25.4%). Regarding complications found after surgery had been performed, 43.4% and 32.8% of the participants, respectively, stated that residual deformity of the operated joint and pain were the complications most seen during the postoperative period. Conclusions Although there was no consensus regarding the treatment and rehabilitation of acromioclavicular dislocation, evolution had occurred in some of the topics analyzed in this questionnaire applied to Brazilian orthopedists. However, further controlled prospective studies are needed in order to evaluate the clinical and scientific benefit of these trends. PMID:26535196
Arliani, Gustavo Gonçalves; Utino, Artur Yudi; Nishimura, Eduardo Misao; Terra, Bernardo Barcellos; Belangero, Paulo Santoro; Astur, Diego Costa
2015-01-01
To evaluate the approaches and procedures used by Brazilian orthopedic surgeons in treatment and rehabilitation of acromioclavicular dislocation of the shoulder. A questionnaire comprising eight closed questions that addressed topics relating to treatment and rehabilitation of acromioclavicular dislocation was applied to Brazilian orthopedic surgeons over the three days of the 45th Brazilian Congress of Orthopedics and Traumatology, in 2013. A total of 122 surgeons completely filled out the questionnaire and formed part of the sample analyzed. Most of them came from the southeastern region of the country. In this sample, 67% of the participants would choose surgical treatment for patients with grade 3 acromioclavicular dislocation. Regarding the preferred technique for surgical treatment of acute acromioclavicular dislocation, a majority of the surgeons used subcoracoid ligature with acromioclavicular fixation and transfer of the coracoacromial ligament (25.4%). Regarding complications found after surgery had been performed, 43.4% and 32.8% of the participants, respectively, stated that residual deformity of the operated joint and pain were the complications most seen during the postoperative period. Although there was no consensus regarding the treatment and rehabilitation of acromioclavicular dislocation, evolution had occurred in some of the topics analyzed in this questionnaire applied to Brazilian orthopedists. However, further controlled prospective studies are needed in order to evaluate the clinical and scientific benefit of these trends.
Reátegui, Diego; Tornero, Eduard; Popescu, Dragos; Sastre, Sergi; Camafort, Miquel; Gines, Gracia; Combalía, Andrés; Lozano, Luis
2017-01-01
The aim of our study was the early detection and treatment of patients with unknown alterations of the hydrocarbon metabolism subject to total knee arthroplasty in order to reduce the incidence of postoperative complications. Patients were classified as non-diabetic patients (group 1), diabetic patients (group 2) and patients with stress hyperglycaemia (group 3). The last two groups were recommended assessment by a primary care physician (PCP). After one year follow-up the groups were compared with respect to incidence of postoperative complications. The groups were also compared regarding the decrease or increase of HbA1c levels with the incidence of complications. Of the 228 patients, 116 (50%) were included in group 1, 40 (17.5%) in group 2 and 72 (31.6%) in group 3. Patients that consulted their PCP presented lower medical complication rates than those who did not (9.2% vs. 26.4%, P=0.020). Not being attended by a PCP was an independent predictive factor of medical complication (odds ratio (OR): 21.3; 95% confidence interval (95% CI): 4.6-98.5), surgical site infection (OR: 4.1; 95% CI: 1.1-15.0) and mechanical complication (OR: 5.0; 95% CI: 1.3-18.8). A decrease of HbA1c value was related to less medical systemic complications (7.3% vs. 24.2%, P=0.035). Patients with hyperglycaemia during the postoperative total knee arthroplasty period, who are controlled by the PCP present lower incidence of complications. Decrease of HbA1c value during postoperative total knee arthroplasty period leads to a lower rate of medical complications. Copyright © 2016 Elsevier B.V. All rights reserved.
Liu, Xudong; Huangfu, Xiaoqiao; Zhao, Jinzhong
2015-05-01
Coracoclavicular (CC) ligament augmentation has been a method to treat acromioclavicular (AC) joint dislocation in recent years. The purpose of this paper is to describe our arthroscopic CC ligament augmentation technique in treating type III and V acute AC joint dislocations and to report the early clinical and radiological results. From 2010 to 2011, twelve patients suffering from acute type III or V AC joint dislocations were arthroscopically treated in our department, by CC ligament augmentation after AC joint reduction. The post-operative outcomes were assessed through physical examination, radiographic examination and the Constant-Murley Shoulder Score. All patients post-operatively experienced anatomical reduction in their AC joint dislocation. No intraoperative complications occurred. At a mean follow-up at 24 months (ranging from 18 to 32 months), the mean Constant-Murley Shoulder Score significantly improved from 24.3 pre-operatively to 91.1 post-operatively. No neurovascular complications or secondary degenerative changes of the AC joint were detected in any of the patients. In one case, a second dislocation occurred 1 month post-operation because the patient had had another traumatic injury. This patient accepted a revision operation, but his AC joint eventually fixated into a subluxated position after his second injury. Based on the resultant successful repair in all cases, the arthroscopic CC ligament augmentation method has thus far proven to be a safe and reliable technique for treatment of acute type III or V AC joint dislocation. The arthroscopic CC ligament augmentation with a flip button/polyethylene belt repair is an efficient method to treat acute type III and V AC joint dislocations which should be popularized. IV.
Hayashi, Ken; Ogawa, Soichiro; Manabe, Shin-Ichi; Hirata, Akira; Yoshimura, Koichi
2016-03-01
The aim of this study was to examine the recent status of intraocular lens (IOL) dislocation according to a classification system based on vertical dislocation position, as well as the surgical techniques and outcomes of IOL exchange surgery. The medical records of 230 eyes from 214 consecutive patients who experienced IOL dislocation and underwent exchange surgery between 2006 and 2014 were reviewed. Vertical dislocation sites observed preoperatively under operating microscopy were examined, along with the surgical techniques and outcomes of IOL exchange. Dislocation sites included (1) the anterior chamber (12.2 %), (2) pseudophakodonesis (19.1 %), (3) the anterior vitreous cavity (47.4 %), (4) trap door-like dislocation (dangling in the peripheral vitreous cavity; 16.1 %), and (5) the retinal surface (5.2 %). The IOL retained in the anterior segment was moved onto the iris by pulling it up through the limbal side ports with an anterior vitrectomy (67.8 %), or by pushing it up from the pars plana with an anterior vitrectomy (26.5 %), while the IOL dropped on the retina was lifting it up from the retina after pars plana vitrectomy (5.7 %). Mean uncorrected and distance-corrected visual acuity significantly improved postoperatively (p < 0.0001). Major complications included a marked elevation in intraocular pressure (7.8 %), pupillary capture (6.5 %), and vitreous hemorrhage (2.6 %). Based on the classification system, approximately 95 % of dislocated IOLs were retained in the anterior segment, and these IOLs were exchanged using an anterior approach through limbal incisions with an anterior vitrectomy. Visual acuity improved significantly, and serious complications were uncommon, probably because the IOL exchange techniques were standardized and simplified without pars plana vitrectomy.
Penile Dislocation with Inversion: A Rare Complication of Blunt Pelvic Injury
Sahadev, Ravindra; Jadhav, Vinay; Munianjanappa, Narendra Babu; Shankar, Gowri
2018-01-01
Penile injuries in children are usually uncommon and are predominantly associated with pelvic trauma or as postcircumcision injuries. The authors present a rare case of penile dislocation with penile inversion in a 5-year-old child occurring due to blunt pelvic injury. The child presented 3 months after pelvic injury with a suprapubic catheter for urinary diversion and absent penis with only penile skin visible. The presence of dislocated penile body was detected on magnetic resonance imaging, which was subsequently confirmed intraoperatively. During the surgery, the dislocated penis was identified and mobilized into its normal anatomical position within the remnant penile skin. Very few cases of penile dislocation have been reported in the literature. Pubic fracture with pulling of suspensory ligament resulting in dislocation of the penis would have been the probable mechanism of injury. PMID:29681700
Roetman, Martijn H; Boeije, Tom; Roodheuvel, Floris; Mullaart-Jansen, Nieke; Peeters, Suzanne; Burg, Mike D
2017-01-01
Introduction Glenohumeral (shoulder) dislocations are the most common large joint dislocations seen in the emergency department (ED). They cause pain, often severe, and require timely interventions to minimise discomfort and tissue damage. Commonly used reposition or relocation techniques often involve traction and/or leverage. These techniques have high success rates but may be painful and time consuming. They may also cause complications. Recently, other techniques—the biomechanical reposition techniques (BRTs)—have become more popular since they may cause less pain, require less time and cause fewer complications. To our knowledge, no research exists comparing the various BRTs. Our objective is to establish which BRT or BRT combination is fastest, least painful and associated with the lowest complication rate for adult ED patients with anterior glenohumeral dislocations (AGDs). Methods and analysis Adults presenting to the participating EDs with isolated AGDs, as determined by radiographs, will be randomised to one of three BRTs: Cunningham, modified Milch or scapular manipulation. Main study parameters/endpoints are ED length of stay and patients’ self-report of pain. Secondary study parameters/endpoints are procedure times, need for analgesic and/or sedative medications, iatrogenic complications and rates of successful reduction. Ethics and dissemination Non-biomechanical AGD repositioning techniques based on traction and/or leverage are inherently painful and potentially harmful. We believe that the three BRTs used in this study are more physiological, more patient friendly, less likely to cause pain, more time efficient and less likely to produce complications. By comparing these three techniques, we hope to improve the care provided to adults with acute AGDs by reducing their ED length of stay and minimising pain and procedure-related complications. We also hope to define which of the three BRTs is quickest, most likely to be successful and least likely to require sedative or analgesic medications to achieve reduction. Trial registration number NTR5839. PMID:28729305
Total knee arthroplasty in limbs affected by poliomyelitis.
Giori, Nicholas J; Lewallen, David G
2002-07-01
Little information is available regarding the results and complications of total knee arthroplasty in limbs affected by poliomyelitis with severe knee degeneration. We performed a retrospective chart and radiograph review of patients with a history of poliomyelitis involving a limb that subsequently underwent primary total knee arthroplasty between 1970 and 2000. Sixteen total knee arthroplasties were performed in limbs affected by poliomyelitis in fifteen patients. Eleven patients were followed for a minimum of two years, one (two knees) died before the minimum two-year follow-up could be completed, and three were followed for less than two years. No patient was lost to follow-up. There were two periprosthetic fractures, one peroneal nerve palsy, one avulsion of the patellar tendon, and four cases of recurrent instability. These complications were related to the poor bone quality, valgus deformity, patella baja, poor musculature, and attenuated soft tissues commonly found in knees affected by poliomyelitis. Knee Society pain and knee scores were improved postoperatively for all nine knees with a two-year follow-up that had had at least antigravity quadriceps strength prior to surgery. However, Knee Society function scores remained at 0 or worsened for six of the eleven knees followed for at least two years, including those with less than antigravity strength, and four of the nine knees with at least antigravity strength. None of the prostheses loosened. Pain and knee scores improved following total knee arthroplasty in patients with a history of poliomyelitis and antigravity quadriceps strength, but there was less pain relief in patients with less than antigravity quadriceps strength. Recurrence of instability and progressive functional deterioration is possible in all knees affected by poliomyelitis that have undergone total knee replacement, but they appear to occur more commonly in more severely affected knees.
Gautam, Arvind; Rani, A Bhargavi; Callejas, Miguel A; Acharyya, Swati Ghosh; Acharyya, Amit; Biswas, Dwaipayan; Bhandari, Vasundhra; Sharma, Paresh; Naik, Ganesh R
2016-08-01
In this paper we introduce Shape Memory Alloy (SMA) for designing the tibial part of Total Knee Arthroplasty (TKA) by exploiting the shape-memory and pseudo-elasticity property of the SMA (e.g. NiTi). This would eliminate the drawbacks of the state-of-the art PMMA based knee-spacer including fracture, sustainability, dislocation, tilting, translation and subluxation for tackling the Osteoarthritis especially for the aged people of 45-plus or the athletes. In this paper a Computer Aided Design (CAD) model using SolidWorks for the knee-spacer is presented based on the proposed SMA adopting the state-of-the art industry-standard geometry that is used in the PMMA based spacer design. Subsequently Ansys based Finite Element Analysis is carried out to measure and compare the performance between the proposed SMA based model with the state-of-the art PMMA ones. 81% more bending is noticed in the PMMA based spacer compared to the proposed SMA that would eventually cause fracture and tilting or translation of spacer. Permanent shape deformation of approximately 58.75% in PMMA based spacer is observed compared to recoverable 11% deformation in SMA when same load is applied on both separately.
[Results and experiences of conversion of hip arthrodesis ].
Schuh, A; Zeiler, G; Werber, S
2005-03-01
With the predictably good outcome of total hip arthroplasty today (THA), hip arthrodesis currently has limited indications. Over the long term, however, most patients develop secondary degenerative arthritis in the spine, contralateral hip, and ipsilateral knee due to overloading. The deteriorating condition of these joints eventually causes the onset of pain, which often requires conversion of a fused hip to a THA. The results and experiences of conversions of a hip arthrodesis into a THA are reported. Between 1 January 1985 and 31 December 2001 conversion of a previously performed arthrodesis of the hip to THA was carried out in a total of 45 patients; 34 patients could be followed up after the conversion to THA after a mean of 77.5 months (min.: 24, max.: 208). The primary indications for the conversion were low back pain (n=21) and ipsilateral knee pain (n=13). The mean age at the time of THA was 75.3 years (min.: 32, max.: 74). The mean time interval between the arthrodesis and the conversion to THA was 30.4 years (min.: 5, max.: 66). Of 34 hips, 29 (85%) were either pain free or had minimal pain. Complications included one persisting sciatic nerve palsy, two superficial infections, two periprosthetic fractures, and two heterotopic ossifications IV degrees with one recurrence of ankylosis and one marked reduction of motion. Revision arthroplasty was performed in four hips. Postoperatively 7 patients showed no limping, 11 showed a slight limp, and 17 a pronounced limp. Recurrent dislocations occurred in one patient. We conclude that this operation can lead to satisfactory results even after a long duration of the arthrodesis. There is a high rate of complications after conversion of a hip arthrodesis to a total hip arthroplasty. These issues must be carefully considered and discussed with the patient before any conversion procedure.
Pugely, Andrew J; Martin, Christopher T; Gao, Yubo; Mendoza-Lattes, Sergio; Callaghan, John J
2013-02-06
Spinal anesthesia has been associated with lower postoperative rates of deep-vein thrombosis, a shorter operative time, and less blood loss when compared with general anesthesia. The purpose of the present study was to identify differences in thirty-day perioperative morbidity and mortality between anesthesia choices among patients undergoing total knee arthroplasty. The American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) database was searched to identify patients who underwent primary total knee arthroplasty between 2005 and 2010. Complications that occurred within thirty days after the procedure in patients who had been managed with either general or spinal anesthesia were identified. Patient characteristics, thirty-day complication rates, and mortality were compared. Multivariate logistic regression identified predictors of thirty-day morbidity, and stratified propensity scores were used to adjust for selection bias. The database search identified 14,052 cases of primary total knee arthroplasty; 6030 (42.9%) were performed with the patient under spinal anesthesia and 8022 (57.1%) were performed with the patient under general anesthesia. The spinal anesthesia group had a lower unadjusted frequency of superficial wound infections (0.68% versus 0.92%; p = 0.0003), blood transfusions (5.02% versus 6.07%; p = 0.0086), and overall complications (10.72% versus 12.34%; p = 0.0032). The length of surgery (ninety-six versus 100 minutes; p < 0.0001) and the length of hospital stay (3.45 versus 3.77 days; p < 0.0001) were shorter in the spinal anesthesia group. After adjustment for potential confounders, the overall likelihood of complications was significantly higher in association with general anesthesia (odds ratio, 1.129; 95% confidence interval, 1.004 to 1.269). Patients with the highest number of preoperative comorbidities, as defined by propensity score-matched quintiles, demonstrated a significant difference between the groups with regard to the short-term complication rate (11.63% versus 15.28%; p = 0.0152). Age, female sex, black race, elevated creatinine, American Society of Anesthesiologists class, operative time, and anesthetic choice were all independent risk factors of short-term complication after total knee arthroplasty. Patients undergoing total knee arthroplasty who were managed with general anesthesia had a small but significant increase in the risk of complications as compared with patients who were managed with spinal anesthesia; the difference was greatest for patients with multiple comorbidities. Surgeons who perform knee arthroplasty may consider spinal anesthesia for patients with comorbidities.
Tamaoki, Marcel Jun Sugawara; Faloppa, Flavio; Wajnsztejn, André; Archetti Netto, Nicola; Matsumoto, Marcelo Hide; Belloti, João Carlos
2012-01-01
Shoulder dislocation is the most common dislocation among the large joints. The aim here was to compare the effectiveness of reduction of acute anterior shoulder dislocation with or without articular anesthesia. Prospective randomized trial conducted in Escola Paulista de Medicina, Universidade Federal de São Paulo (EPM-Unifesp). From March 2008 to December 2009, 42 patients with shoulder dislocation were recruited. Reductions using traction-countertraction for acute anterior shoulder dislocation with and without lidocaine articular anesthesia were compared. As the primary outcome, pain was assessed through application of a visual analogue scale before reduction, and one and five minutes after the reduction maneuver was performed. Complications were also assessed. Forty-two patients were included: 20 in the group without analgesia (control group) and 22 in the group that received intra-articular lidocaine injection. The group that received intra-articular lidocaine had a statistically greater decrease in pain over time than shown by the control group, both in the first minute (respectively: mean 2.1 (0 to 5.0), standard deviation, SD 1.3, versus mean 4.9 (2.0 to 7.0, SD 1.5; P < 0.001) and the fifth minute (respectively: mean 1.0; 0 to 3.0; SD = 1.0 versus mean 4.0; 1.0 to 6.0; SD = 1.4; P < 0.001). There was one failure in the control group. There were no other complications in either group. Reduction of anterior shoulder dislocation using intra-articular lidocaine injection is effective, since it is safe and diminishes the pain. ISRCTN27127703.
Soranoglou, Vasileios G; Poultsides, Lazaros A; Wanivenhaus, Florian; Nocon, Allina A; Triantafyllopoulos, Georgios K; Sculco, Peter K; Memtsoudis, Stavros G; Sculco, Thomas P
2018-06-01
Same-day Bilateral Total Knee Arthroplasty (BTKA) safety is still controversial. The aim of this study was to examine the association of blood transfusion type (pure autologous, pure allogeneic, and combined) with complication and prolonged length of stay (PLOS) following same-day BTKA. 649 consecutive patients were retrospectively identified over a two-year period. Pure allogeneic transfusions were associated with increased odds of minor complication when compared to patients who had pure autologous transfusions. No association was found between blood transfusion type and major complication or PLOS. Our results suggest that blood transfusion type may be influential in minor complication after BTKA.
Neglected bilateral congenital dislocation of the patella.
Tokgöz, Mehmet Ali; Çavuşoğlu, Ali Turgay; Ayanoğlu, Tacettin; Elma, Tarık; Vural, Abdurrahman
2017-08-01
Congenital dislocation of the patella is a disorder that presents with dysfunction in extensor mechanism. Although congenital dislocation of the patella mostly occurs in children with genetic disorders, it may also occur in totally healthy children, despite rarely. In this article, we report a 16-year-old male patient who referred to our clinic with complaints of gait disturbance, frequent falls, and muscular weakness in lower extremity. The patient had no complaints during walking, but had difficulty in running and walking up and down the stairs. It was observed that the range of motion of the knee joint was completely painless and the quadriceps muscle strength was evaluated as 3/5. An evaluation of computed tomography and magnetic resonance imaging results showed that the patella was dislocated. It became clear with magnetic resonance imaging that extensor mechanism was continuous but patellar tendon was not attached to its anatomical position. Surgical treatment was not planned because the patient did not describe any pain complaint and there was no limitation of joint movement, he could walk without support and without device and also refused to be operated. The choice of treatment should be based on the patient's preference, and pain and functional status.
Moitrel, G; Roumazeille, T; Arnould, A; Migaud, H; Putman, S; Ramdane, N; Pasquier, G
2015-10-01
Medial patellofemoral ligament (MPFL) reconstruction associated to anterior tibial tuberosity transfer (ATTT) is recommended in objective patellofemoral instability (PFI). Efficacy, however, has not been precisely determined in trochlear dysplasia with spur. A case-control study was performed in a PFI population, comparing groups with trochlear dysplasia with and without spur (S+ vs. S-) to assess the impact of trochlear dysplasia on (1) patellofemoral stability, (2) functional results and complications, and (3) patellofemoral cartilage status on MRI. Trochlear spur does not affect outcome in PFI managed by MPFL reconstruction and ATTT. Twenty-eight knees (26 patients) with PFI were analyzed retrospectively and divided into 2 groups of 14 knees each according to presence of trochlear spur (S+ vs. S-). All 28 knees had undergone ATTT and MPFL reconstruction by semitendinosus autograft. Results were assessed on Lille and IKDC functional scores, and cartilage status was determined on MRI at last follow-up. At a mean 24 months' follow-up (range, 12-52 months), there was no recurrence of dislocation. IKDC and Lille scores tended to improve in both groups, although the only significant improvement was in IKDC score (S- gain, 21.3±16; S+ gain, 18.1±14) (P=0.01). IKDC scores at last follow-up were better in the S+ than S- group (79±19 [range, 21-92] vs. 68±13 [range, 35-84], respectively; P=0.012). Lille scores showed no significant inter-group differences in mean gain (P=0.492) or mean value (P=0.381). The S+ group showed more cartilage lesions (n=14/14 knees, including 12/14 with grade≥2 lesions) than the S- group (n=9/14 knees, all grade≤2). MPFL reconstruction with ATTT provided good short-term patellofemoral stability independently of the severity of trochlear dysplasia. Functional results and gain on IKDC, however, were poorer in case of dysplasia with trochlear spur. This is probably due to cartilage lesions, observed more frequently pre- and post-operatively in the spur group, especially as there was no significant difference in Lille Score, which highlights stability. III, retrospective case-control study. Copyright © 2015. Published by Elsevier Masson SAS.
Double-button Fixation System for Management of Acute Acromioclavicular Joint Dislocation
Torkaman, Ali; Bagherifard, Abolfazl; Mokhatri, Tahmineh; Haghighi, Mohammad Hossein Shabanpour; Monshizadeh, Siamak; Taraz, Hamid; Hasanvand, Amin
2016-01-01
Background: Surgical treatments for acromioclavicular (AC) joint dislocation present with some complications. The present study was designed to evaluate the double-button fixation system in the management of acute acromioclavicular joint dislocation. Methods: This cross sectional study, done between February 2011 to June 2014, consisted of 28 patients who underwent surgical management by the double-button fixation system for acute AC joint dislocation. Age, sex, injury mechanism, dominant hand, side with injury, length of follow up, time before surgery, shoulder and hand (DASH), constant and visual analogue scale (VAS) scores, and all complications of the cases during the follow up were recorded. Results: The mean age of patients was 33.23±6.7 years. Twenty four patients (85.71%) were male and four (14.28%) were female. The significant differences were observed between pre-operation VAS, constant shoulder scores and post-operation measurements. There were not any significant differences between right and left coracoclavicular, but two cases of heterotrophic ossifications were recorded. The mean follow-up time was 16.17±4.38 months. Conclusion: According to the results, the double-button fixation system for management of acute acromioclavicular joint dislocation has suitable results and minimal damage to the soft tissues surrounding the coracoclavicular ligaments. PMID:26894217
Jiang, Chao; Liu, Zhenlei; Wang, Ying; Bian, Yanyan; Feng, Bin; Weng, Xisheng
2016-01-01
Although being debated for many years, the superiority of posterior cruciate-retaining (CR) total knee arthroplasty (TKA) and posterior-stabilized (PS) TKA remains controversial. We compare the knee scores, post-operative knee range of motion (ROM), radiological outcomes about knee kinematic and complications between CR TKA and PS TKA. Literature published up to August 2015 was searched in PubMed, Embase and Cochrane databases, and meta-analysis was performed using the software, Review Manager version 5.3. Totally 14 random control trials (RCTs) on this topic were included for the analysis, which showed that PS and CR TKA had no significant difference in Knee Society knee Score (KSS), pain score (KSPS), Hospital for Special Surgery score (HSS), kinematic characteristics including postoperative component alignment, tibial posterior slope and joint line, and complication rate. However, PS TKA is superior to CR TKA regarding post-operative knee range of motion (ROM) [Random Effect model (RE), Mean Difference (MD) = -7.07, 95% Confidential Interval (CI) -10.50 to -3.65, p<0.0001], improvement of ROM (Fixed Effect model (FE), MD = -5.66, 95% CI -10.79 to -0.53, p = 0.03) and femoral-tibial angle [FE, MD = 0.85, 95% CI 0.46 to 1.25, p<0.0001]. There are no clinically relevant differences between CR and PS TKA in terms of clinical, functional, radiological outcome, and complications, while PS TKA is superior to CR TKA in respects of ROM, while whether this superiority matters or not in clinical practice still needs further investigation and longer follow-up.
Ling, Barbara M; Wettstein, Reto; Staub, Daniel; Schaefer, Dirk J; Kalbermatten, Daniel F
2018-02-07
The gastrocnemius muscle flap may be considered the first choice in many cases of soft-tissue reconstruction about the knee. Limited arc of rotation and reach of the flap as well as unsightly muscle bulk are major disadvantages and were the impetus to look for a local alternative. The aim of this study is to present a consecutive series of patients with a reconstruction about the knee involving the medial sural artery perforator flap (MSAPF). A consecutive series of 17 cases of defect reconstructions about the knee using the MSAPF is described, with an emphasis on early postoperative complications. No major flap-related complications occurred except 1 case of tip necrosis that healed uneventfully after excision and secondary suture. Two patients with direct donor-site closure had a minor complication that required no revision, and 2 had partial skin-graft loss. In summary, use of this pedicled perforator flap represents a reliable technique for soft-tissue reconstruction about the knee with an acceptable complication rate and optimal contour reconstruction without the need for a skin graft and secondary debulking procedures. The range of motion associated with the MSAPF in comparison to the range associated with the gastrocnemius muscle flap is increased so that more proximal and lateral defects can be covered. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Mabry, Tad M; Jacofsky, David J; Haidukewych, George J; Hanssen, Arlen D
2007-11-01
We analyzed knee arthrodesis for the infected total knee replacement (TKR) using two different fixation techniques. Patients undergoing knee arthrodesis for infected TKR were identified and rates of successful fusion and recurrence of infection were compared using Cox proportional hazard models. Eighty-five consecutive patients who underwent knee arthrodesis were followed until union, nonunion, amputation, or death. External fixation achieved successful fusion in 41 of 61 patients and was associated with a 4.9% rate of deep infection. Fusion was successful in 23 of 24 patients with intramedullary (IM) nailing and was associated with an 8.3% rate of deep infection. We observed similar fusion and infection rates with the two techniques. Thirty-four patients (40%) had complications. Knee arthrodesis remains a reasonable salvage alternative for the difficult infected TKR. Complication rates are high irrespective of the technique, and one must consider the risks of both nonunion and infection when choosing the fixation method in this setting. IM nailing appears to have a higher rate of successful union but a higher risk of recurrent infection when compared with external fixation knee arthrodesis. Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
New insights in the treatment of acromioclavicular separation
van Bergen, Christiaan J A; van Bemmel, Annelies F; Alta, Tjarco D W; van Noort, Arthur
2017-01-01
A direct force on the superior aspect of the shoulder may cause acromioclavicular (AC) dislocation or separation. Severe dislocations can lead to chronic impairment, especially in the athlete and high-demand manual laborer. The dislocation is classified according to Rockwood. Types I and II are treated nonoperatively, while types IV, V and VI are generally treated operatively. Controversy exists regarding the optimal treatment of type III dislocations in the high-demand patient. Recent evidence suggests that these should be treated nonoperatively initially. Classic surgical techniques were associated with high complication rates, including recurrent dislocations and hardware breakage. In recent years, many new techniques have been introduced in order to improve the outcomes. Arthroscopic reconstruction or repair techniques have promising short-term results. This article aims to provide a current concepts review on the treatment of AC dislocations with emphasis on recent developments. PMID:29312844
Long-term outcome of 42 knees with chronic infection after total knee arthroplasty.
Bose, W J; Gearen, P F; Randall, J C; Petty, W
1995-10-01
The outcome of treatment in 40 patients (42 knees) with chronic infections after total knee arthroplasty was reviewed. Eighteen knees were treated with a 2-stage reimplantation. Sixteen of these 18 knees were treated with antibiotic-containing beads between debridement and reimplantation, and 7 of these were also treated with antibiotics in the cement at reimplantation. Infection did not recur in any of these 18 knees. Clinically, the 2-stage reimplantation group averaged a score of 90 points on the Knee Society Clinical Rating System. Average function score was 86.5 points, with average range of motion from 2 degrees to 109 degrees. Sixteen knees were treated with an arthrodesis: 9 with a 1-stage technique with a uniplanar external fixator and 7 with a 2-stage technique with intramedullary nail internal fixation. Infection did not recur in 6 of 9 knees treated with the 1-stage technique, but only 2 had a solid arthrodesis. All 7 treated with the 2-stage intramedullary nail technique had no recurrence of infection and achieved a solid fusion. Reimplantation or arthrodesis was not attempted in 8 other knees because of recalcitrant infection, vascular complications, or medical infirmity. Of the 42 knees, 11 (26%) had a severely morbid outcome. The infection could not be eradicated in 7 knees: 6 required amputation and 1 had a solid fusion but chronic drainage. In 3 knees, the infection was cured but resection arthroplasties were required, and in 1 patient an amputation was needed as a result of an intraoperative vascular complication.
Choi, Nam Hong; Lim, Seok Min; Lee, Sang Young; Lim, Tae Kang
2017-04-01
This study was conducted to report loss of reduction and complications after single-tunnel coracoclavicular (CC) ligament reconstruction with autogenous semitendinosus tendon graft for acute acromioclavicular (AC) joint dislocations. This retrospective study included patients with acute, unstable AC dislocations (surgery within 6 weeks after trauma). We excluded patients with chronic injury and distal clavicle fractures with CC ligaments disruption. We measured the CC distance on anteroposterior radiographs of both clavicles, preoperatively, immediately postoperatively, and at the final follow-up visit. We evaluated clinical outcomes using the American Shoulder and Elbow Surgeons Shoulder Assessment and the University of California, Los Angeles Shoulder Rating Scale scores and perioperative complications. There were 30 patients (27 men and 3 women) with mean age of 41 years (range, 19-70 years). The mean follow-up period was 31 months (range, 12-186 months). Mean CC distance was 15.5 ± 3.7 mm (84% ± 14% of the contralateral shoulder) preoperatively, 8.9 ± 2.6 mm (9% ± 40%) immediately postoperatively (P < .001), and 10.6 ± 3.3 mm (24% ± 39%) at the final assessment (P < .001), showing an increase of the CC distance during the follow-up. Loss of reduction (defined as >25% increase of CC distance) developed in 14 patients (47%), and complications occurred in 6 patients (20%), including 3 distal clavicle fractures through the tunnel. Final clinical scores were significantly lower in patients with complications (27 vs. 33 of the University of California, Los Angeles assessment [P < .001] and 81 vs. 95 of the American Shoulder and Elbow Surgeons Shoulder assessment [P < .001]). In acute AC joint dislocation, single-tunnel CC ligament reconstruction using autogenous tendon graft resulted in loss of reduction rate of 47% and a complication rate of 20%. The development of complications adversely affected clinical outcomes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Dislocation of the penis: a rare complication after traumatic pelvic injury
Lim, Mei Chin; Srinivasan, Sivasubramanian; Teh, Hui Seong; Teo, Chang Peng Colin
2015-01-01
Traumatic injury to the male external genitalia is frequently encountered, but acute traumatic dislocation of the penile structure is extremely rare, with only a few reports found in the literature. We herein report the case of a 21-year-old man who sustained blunt trauma to the pelvis following a motor vehicle accident, and had features suspicious of penile dislocation. With the use of computed tomography and bedside ultrasonography, a diagnosis of penile dislocation was made, which was subsequently confirmed intraoperatively. Immediate surgical intervention via gentle manipulation of the penile tissue back to its native position was performed in order to restore normal anatomy. The exact mechanism of penile dislocation is not known. However, circumferential laceration around the foreskin causing degloving injury of the penis is suggested in our patient. PMID:25640107
Cool, Steve; Victor, Jan; De Baets, Thierry
2006-12-01
Fifty unicompartmental knee arthroplasties (UKAs) were performed through a minimally invasive approach and were reviewed with an average follow-up of 3.7 years. This technique leads to reduced access to surgical landmarks. The purpose of this study was to evaluate whether correct component positioning is possible through this less invasive approach. Component positioning, femorotibial alignment and early outcomes were evaluated. We observed perfect tibial component position, but femoral component position was less consistent, especially in the sagittal plane. Femorotibial alignment in the coronal plane was within 2.5 degrees of the desired axis for 80% of the cases. Femoral component position in the sagittal plane was within a 10 degrees range of the ideal for 70% of the cases. The mean IKS Knee Function Score and Knee Score were 89/100 and 91/100 respectively. We observed two polyethylene dislocations, and one revision was performed for progressive patellofemoral arthrosis. According to our data, minimally invasive UKA does not conflict with component positioning although a learning curve needs to be respected, with femoral component positioning as the major obstacle.
Revision surgery due to magnet dislocation in cochlear implant patients: an emerging complication.
Hassepass, Frederike; Stabenau, Vanessa; Maier, Wolfgang; Arndt, Susan; Laszig, Roland; Beck, Rainer; Aschendorff, Antje
2014-01-01
To analyze the cause and effect of magnet dislocation in cochlear implant (CI) recipients requiring magnet revision surgery for treatment. Retrospective study. Tertiary referral center. Case reports from 1,706 CI recipients consecutively implanted from January 2000 to December 2011 were reviewed. The number of cases requiring magnet revision surgery was assessed. Revision surgery involving magnet removal or replacement was indicated in 1.23% (21/1,706), of all CI recipients. Magnet dislocation occurring during magnetic resonance tomography (MRI), at 1.5 Tesla (T), with the magnet in place and with the application of compression bandaging around the head, was the main cause for revision surgery in 47.62% (10/21) of the affected cases. All 10 cases were implanted with Cochlear Nucleus cochlear implants. These events occurred, despite adherence to current recommendations of the manufacturer. The present study underlines that MRI examination is the main cause of magnet dislocation. The use of compressive bandaging when using 1.5-T MRI does not eliminate the risk of magnet dislocation. Additional cautionary measures are for required for conditional MRI. We recommend X-ray examination after MRI to determine magnet dislocation and avoid major complications in all cases reporting pain during or after MRI. Additional research regarding silicon magnet pocket design for added retention is needed. Effective communication of guidelines for precautionary measures during MRI examination in CI patients is mandatory for all clinicians involved. MRI in CI recipients should be indicated with caution.
Hoell, Steffen; Sander, Marius; Gosheger, Georg; Ahrens, Helmut; Dieckmann, Ralf; Hauschild, Gregor
2014-03-12
There have been increasing numbers of publications in recent years on minimally invasive surgery (MIS) for total hip arthroplasty (THA), reporting results with the use of different head sizes, tribologic and functional outcomes. This study presents the results and early complication rates after THA using the direct anterior approach (DAA) in combination with head sizes ≥ 36 mm. A total of 113 patients with THA were included in the study. The Harris Hip Score (HHS) was determined, a radiographic evaluation was carried out, and complications were recorded. The minimum follow-up period was 2 years (means 35 ± 7 months). The HHS improved from 43.6 (± 12) to 88.2 (± 14; P < 0.01). One early infection occurred, one periprosthetic fracture, and three cases of aseptic stem loosening. No incorrect positioning of the implants was observed, and there were no dislocations. THA with the minimally invasive DAA in combination with large heads is associated with good to very good functional results in the majority of cases. The complication rates are not increased. The rate of dislocation mainly as an complication of the first two years can be markedly reduced in particular.
Rare Complication in Third Maxillary Molar Extraction: Dislocation in Infratemporal Fossa.
Battisti, Andrea; Priore, Paolo; Giovannetti, Filippo; Barbera, Giorgio; D'Alessandro, Francesco; Valentini, Valentino
2017-10-01
Removal of impacted third maxillary molar is frequently carried out without difficulties and low rate of intraoperative complications. The rare and particularly challenger to manage it is the third molar dislocation into the infratemporal fossa (IF). In this clinical report, the authors present their solution to manage and resolve this particular complication. A 28-year-old woman was referred to the emergency rescue unit of the authors' hospital by her dentistry, after the attempt to extract the left impacted maxillary third molar. During the procedure the tooth accidentally dislodged and was lost sight of it. The patient had significant mouth-opening limitation, omolateral mid face swelling and pain. Computer tomography was immediately performed to determine the exact position of the tooth, showing the dental element dislocated into the IF. Considering all of possible complications the best surgical option must guarantee a direct approach and a constant eye contact of the tooth, even in case of further displacement during the procedure, and allow early surgery. The authors used an endoscopic transoral approach through the preexisted access and solved all the issues reducing morbidity. Removing tooth from the IF could be burdened by serious risk of bleeding and/or nerve injury. The endoscopic approach provides direct view of the IF reducing morbidity.
Arthrodesis of the knee using a custom-made intramedullary coupled device.
White, S P; Porteous, A J; Newman, J H; Mintowt-Czyz, W; Barr, V
2003-01-01
Nine patients underwent arthrodesis of the knee using customised coupled nail (the Mayday arthrodesis nail), five after infected arthroplasty, one following failed arthrodesis, one for intractable anterior knee pain, one for Charcot instability and one after trauma. Comparison was made with 17 arthrodeses, eight undertaken using external fixation, four with dual compression plates, and five with long Kütntscher nails. Union was achieved in all patients (100%) at a mean time of ten months using the customised implant. There were no complications despite early weight-bearing. No further procedures were required. This contrasted with a rate of union of 53% and a complication rate of 76% with alternative techniques. Of this second group, 76% required a further operative procedure. We compared the Mayday arthrodesis nail with other techniques of arthrodesis of the knee. The differences in the need for further surgery and occurrence of complications were statistically significant (p < 0.001), and differences in the rate of nonunion and inpatient stay of less than three weeks were also significant (p < 0.05) using Fisher's exact test. We conclude that a customised coupled intramedullary nail can give excellent stability allowing early weight-bearing, and results in a high rate of union with minimal postoperative complications.
A forgotten retained drain inside a knee for 10 years: A case report.
Koaban, Saeed; Alatassi, Raheef; Alogayyel, Nawaf
2018-05-29
Surgical drains are inserted into the wound after an arthroscopic knee procedure mainly to decrease fluid collection after the operation. The use of postoperative surgical drains remains controversial. This report presents a rare case of a forgotten retained drain that was accidentally found inside a knee 10 years after an arthroscopic procedure. The drain was removed without any complications. A retained and broken drain during removal is a very rare and preventable complication that can be stressful for both the patient and surgeon. Most of the literature supports that retained drains in the soft tissues do not affect long-term outcomes, but if the drain fragment is in the intra-articular area, it might cause complications. Furthermore, there are several preventive measures to avoid retained surgical drains. By reporting this case of a forgotten drain retained inside a knee for approximately 10 years, we aim to illustrate the potential risk of leaving a drain inside the joint following an arthroscopic procedure. Furthermore, we advise that surgeons maintain a high index of suspicion for iatrogenic complications when a patient continues to complain about unexplained pain at the surgical site. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Clifford, Anton G; Gabriel, Stefan M; O’Connell, Mary; Lowe, David; Miller, Larry E; Block, Jon E
2013-01-01
Symptomatic medial compartment knee osteoarthritis (OA) is the leading cause of musculoskeletal pain and disability in adults. Therapies intended to unload the medial knee compartment have yielded unsatisfactory results due to low patient compliance with conservative treatments and high complication rates with surgical options. There is no widely available joint-unloading treatment for medial knee OA that offers clinically important symptom alleviation, low complication risk, and high patient acceptance. The KineSpring® Knee Implant System (Moximed, Inc, Hayward, CA, USA) is a first-of-its-kind, implantable, extra-articular, extra-capsular prosthesis intended to alleviate knee OA-related symptoms by reducing medial knee compartment loading while overcoming the limitations of traditional joint-unloading therapies. Preclinical and clinical studies have demonstrated excellent prosthesis durability, substantial reductions in medial compartment and total joint loads, and clinically important improvements in OA-related pain and function. The purpose of this report is to describe the KineSpring System, including implant characteristics, principles of operation, indications for use, patient selection criteria, surgical technique, postoperative care, preclinical testing, and clinical experience. The KineSpring System has potential to bridge the gap between ineffective conservative treatments and irreversible surgical interventions for medial compartment knee OA. PMID:23717052
Complications Are Not Increased With Acetabular Revision of Metal-on-metal Total Hip Arthroplasty.
Penrose, Colin T; Seyler, Thorsten M; Wellman, Samuel S; Bolognesi, Michael P; Lachiewicz, Paul F
2016-10-01
Isolated revision of the acetabular component in the setting of total hip arthroplasty has an increased risk of dislocation. With local soft tissue destruction frequently associated with failed metal-on-metal (MoM) bearings, it is presumed that acetabular revision of these hips will have even greater risk of complications. However, no study directly compares the complications of MoM with metal-on-polyethylene (MoP) acetabular revisions. In the context of a large database analysis, we asked the following questions: (1) Are there differences in early medical or wound complications after isolated acetabular revision of MoM and MoP bearing surfaces? (2) Are there differences in the frequency of dislocation, deep infection, and rerevision based on the bearing surface of the original implant? A review of the 100% Medicare database from 2005 to 2012 was performed using International Classification of Diseases, 9th Revision and Current Procedural Terminology codes. We identified 451 patients with a MoM bearing and 628 patients with a MoP bearing who had an isolated acetabular revision and a minimum followup of 2 years. The incidence, odds ratios, and 95% confidence intervals for early medical or wound complications were calculated using a univariate analysis at 30 days with patient sex and age group-adjusted analysis for blood transfusion. The incidence, odds ratio, and 95% confidence intervals for dislocation, deep infection, and rerevision were calculated using a univariate analysis at 30 day, 90 days, 1 year, and 2 years using a subgroup analysis with the Cochran-Mantel-Haenszel test to adjust for patient gender and age groups. There were no differences between the MoM and MoP isolated acetabular revisions in the incidence of 30-day local complications. There was a greater risk of transfusion in the MoP group than the MoM group (134 of 451 [30%] versus 230 of 628 [37%]; odds ratio [OR], 0.731; 95% confidence interval [CI], 0.565-0.948; p = 0.018). There were no differences at 2 years between the MoM and MoP acetabular revisions in the incidence of dislocation, infection, or rerevision. When analyzed by patient sex and age group, there were more infections in the age 70 to 79 years MoP group compared with MoM (10 of 451 [5%] versus 29 of 628 [10%]; OR, 4.47; CI, 1.699-11.761; p = 0.001). There were high rates of dislocation, infection, and rerevision in both revision cohorts. The rate of dislocation was not greater after acetabular revision of MoM bearings at 2 years. Based on these findings, clinicians should counsel these patients preoperatively about the risks of these complications. Dual-mobility and constrained components have specific advantages and disadvantages in these settings and should be further studied. Level III, therapeutic study.
Minimally Invasive Repair of Pectus Excavatum Without Bar Stabilizers Using Endo Close.
Pio, Luca; Carlucci, Marcello; Leonelli, Lorenzo; Erminio, Giovanni; Mattioli, Girolamo; Torre, Michele
2016-02-01
Since the introduction of the Nuss technique for pectus excavatum (PE) repair, stabilization of the bar has been a matter of debate and a crucial point for the outcome, as bar dislocation remains one of the most frequent complications. Several techniques have been described, most of them including the use of a metal stabilizer, which, however, can increase morbidity and be difficult to remove. Our study compares bar stabilization techniques in two groups of patients, respectively, with and without the metal stabilizer. A retrospective study on patients affected by PE and treated by the Nuss technique from January 2012 to June 2013 at our institution was performed in order to evaluate the efficacy of metal stabilizers. Group 1 included patients who did not have the metal stabilizer inserted; stabilization was achieved with multiple (at least four) bilateral pericostal Endo Close™ (Auto Suture, US Surgical; Tyco Healthcare Group, Norwalk, CT) sutures. Group 2 included patients who had a metal stabilizer placed because pericostal sutures could not be used bilaterally. We compared the two groups in terms of bar dislocation rate, surgical operative time, and other complications. Statistical analysis was performed with the Mann-Whitney U test and Fisher's exact test. Fifty-seven patients were included in the study: 37 in Group 1 and 20 in Group 2. Two patients from Group 2 had a bar dislocation. Statistical analysis showed no difference between the two groups in dislocation rate or other complications. In our experience, the placement of a metal stabilizer did not reduce the rate of bar dislocation. Bar stabilization by the pericostal Endo Close suture technique appears to have no increase in morbidity or migration compared with the metal lateral stabilizer technique.
Tins, Bernhard
2011-07-01
Metal on metal resurfacing hip implants are known to have complications unique to this type of implant. The case presented adds a further previously not described complication, the dislocation and spontaneous reduction of the pin of the femoral component against the femoral neck. The radiographic and CT findings are demonstrated. The dislocation was aided by bone loss due to an infection with a large periarticular collection. Periarticular collections in hip resurfacings are often due to a hypersensitivity type reaction to metal debris. However in the case presented it was due to infection. MRI was not able to discern the infection from a sterile collection. CT demonstrated bone loss and periosteal reaction suggestive of infection. In addition calcification of the pseudocapsule was seen, this is not a recognized feature of sterile collections. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Berkov, D. V.; Gorn, N. L.
2018-06-01
In this paper we present a simple and effective numerical method which allows a fast Fourier transformation-based evaluation of stress generated by dislocations with arbitrary directions and Burgers vectors if the (site-dependent) dislocation density is known. Our method allows the evaluation of the dislocation stress using a rectangular grid with shape-anisotropic discretization cells without employing higher multipole moments of the dislocation interaction coefficients. Using the proposed method, we first simulate the stress created by relatively simple non-homogeneous distributions of vertical edge and so-called ‘mixed’ dislocations in a disk-shaped sample, which is necessary to understand the dislocation behavior in more complicated systems. The main part of our research is devoted to the stress distribution in polycrystalline layers with the dislocation density rapidly varying with the distance to the layer bottom. Considering GaN as a typical example of such systems, we investigate dislocation-induced stress for edge and mixed dislocations, having random orientations of Burgers vectors among crystal grains. We show that the rapid decay of the dislocation density leads to many highly non-trivial features of the stress distributions in such layers and study in detail the dependence of these features on the average grain size. Finally we develop an analytical approach which allows us to predict the evolution of the stress variance with the grain size and compare analytical predictions with numerical results.
Traumatic anterior dislocation of the crystalline lens and its surgical management.
Srećković, Sunčica; Janićijević Petrović, Mirjana; Jovanović, Svetlana; Paunović, Svetlana; Sarenac, Tatjana
2012-02-01
This paper reports a case of a 57-year old female who had sustained a blunt ocular trauma resulting in anterior dislocation of the crystalline lens and acute painful visual loss in the left eye. The patient was managed with anterior chamber intracapsular phacoemulsification through a small anterior capsulotomy, pars plana vitrectomy, and surgical iridotomy. Aphakia was corrected by a contact lens. Two months after the surgery, the best corrected visual acuity was 0.9 in the left eye. The vision and retina remained stable in her follow-up examination 1 year later. Anterior dislocation of the crystalline lens can cause severe complications so that dislocated lens should be removed immediately.
Growth rate effects on the formation of dislocation loops around deep helium bubbles in Tungsten
Sandoval, Luis; Perez, Danny; Uberuaga, Blas P.; ...
2016-11-15
Here, the growth process of spherical helium bubbles located 6 nm below a (100) surface is studied using molecular dynamics and parallel replica dynamics simulations, over growth rates from 10 6 to 10 12 helium atoms per second. Slower growth rates lead to a release of pressure and lower helium content as compared with fast growth cases. In addition, at slower growth rates, helium bubbles are not decorated by multiple dislocation loops, as these tend to merge or emit given sufficient time. At faster rates, dislocation loops nucleate faster than they can emit, leading to a more complicated dislocation structuremore » around the bubble.« less
Stengel, Dirk; Casper, Dirk; Bauwens, Kai; Ekkernkamp, Axel; Wich, Michael
2009-09-01
Biodegradable cross-pins have been shown to provide higher failure loads than do screws for fixation of hamstring tendons under laboratory conditions. To compare the clinical results of biodegradable pins (RigidFix) and interference screws (BioCryl) for fixation of hamstring grafts in arthroscopically assisted anterior cruciate ligament reconstruction. Study Design Randomized controlled trial; Level of evidence, 1. To test the hypothesis of a difference of 1.0 +/- 1.2 mm in anterior knee laxity between the two fixation options, 54 patients were randomly assigned to groups via a block randomization scheme and sealed envelopes. All patients underwent standardized hamstring graft reconstruction and had similar postoperative aftercare by an accelerated rehabilitation protocol. Measures assessed at baseline and after 1 and 2 years of follow-up included (1) the side-to-side difference in anterior laxity (KT-1000 arthrometer), (2) Short Form 36 physical and mental component scores, and (3) the International Knee Documentation Committee form scores. After 1 and 2 years, 26 and 21 patients in the BioCryl group and 28 and 24 patients in the RigidFix group were available for follow-up examination. No significant difference was noted in instrumented anterior translation between BioCryl and RigidFix fixation: 1 year, 0.11 (95% CI, -0.60 to 0.82; P = .7537); 2 years, 0.33 (95% CI, -0.43 to 1.08 mm; P = .3849). Also, there were no significant differences in the mean physical and mental component scores and International Knee Documentation Committee form scores and in overall complication and surgical revision rates. A pin dislocation was classified as the sole procedure-specific serious adverse event. Bioresorbable pins do not provide better clinical results than do resorbable interference screws for hamstring graft fixation in anterior cruciate ligament reconstruction surgery.
An isolated dorso-medial dislocation of navicular bone: A case report.
Singh, Varun Kumar; Kashyap, Abhishek; Vargaonkar, Gauresh; Kumar, Ramesh
2015-03-01
An isolated dislocation of tarsal navicular is extremely rare injury. Usually it is associated with fracture of navicular itself or other tarsal bones of foot along with disruption of medial or lateral column of foot. Mechanism of injury is complex but usually a severe abduction force is required to produce such injury in a planter flexed foot. A 30 year old male presented with isolated navicular dislocation. Management required open reduction and fixation with k-wires. These injuries have specific complications including avascular necrosis of navicular and post-traumatic arthritis.
Osztheimer, István; Szilágyi, Szabolcs; Pongor, Zsuzsanna; Zima, Endre; Molnár, Levente; Tahin, Tamás; Özcan, Emin Evren; Széplaki, Gábor; Merkely, Béla; Gellér, László
2017-06-01
Lead dislocations of pacemaker systems are reported in all and even in high-volume centers. Repeated procedures necessitated by lead dislocations are associated with an increased risk of complications. We investigated a minimal invasive method for right atrial and ventricular lead repositioning. The minimal invasive method was applied only when passive fixation leads were implanted. During the minimal invasive procedure, a steerable catheter was advanced through the femoral vein to move the distal end of the lead to the appropriate position. Retrospective data collection was conducted in all patients with minimal invasive and with conventional method, at a single center between September 2006 and December 2012. Forty-five minimal invasive lead repositionings were performed, of which eight were acutely unsuccessful and nine electrodes re-dislocated after the procedure. One hundred two leads were repositioned with opening of the pocket during the same time, including the ones with unsuccessful minimal invasive repositionings. One procedure was acutely unsuccessful in this group and four re-dislocations happened. A significant difference of success rates was noted (66.6% vs. 95.1%, p = 0.001). One complication was observed during the minimal invasive lead repositionings (left ventricular lead microdislodgement). Open-pocket procedures showed different types of complications (pneumothorax, subclavian artery puncture, pericardial effusion, hematoma, fever, device-associated infection which necessitated explantation, atrial lead dislodgement while repositioning the ventricular one, deterioration of renal function). The minimal invasive method as a first alternative is safe and feasible. In those cases when it cannot be carried out successfully, the conventional method is applicable.
Zhang, Xin; Wei, Qiang; Ji, Fang; Tong, Da-Ke; Tang, Hao; Zhang, Hao; Yu, Jin-Guo; Yang, Ji-Dong; Cui, Rui; Huo, Ning-Ning
2018-05-25
To investigate the efficacy and complications of manual reduction and external fixation for the treatment of scaphoid fractures and perilunate dislocations. From January 2009 to January 2013, 43 patients suffered from scaphoid fractures and perilunate dislocations were retrospective analyzed. Among them, 17 cases were treated with manipulative reduction and plaster external fixation as conservation group including 10 males and 7 females, the other 26 cases were treated with application of surgical as operation group including 15 males and 11 females. The clinical effects were assessed by Cooney function score, radiological analysis and observation of complications. All patients were followed up for(45.00±8.72) months ranging from 36 to 60 months. At the final follow-up, the Cooney score of wrist function was 88.53±4.24 in conservation group and 89.58±4.59in operation group( t= 0.455, P >0.05). During the follow-up, 4 patients were found scaphoid avascular necrosis in the imaging performance in the conservation group(χ²=4.32, P <0.05). The difference of other complications between two groups was not statistically significant( P >0.05). For patients suffered from the scaphoid fractures and perilunate dislocation, the early manipulative reduction and plaster external fixation after injury as soon as possible is necessary. Maintaining a satisfactory reduction and reliable fixation at the same time can lead to good treatment effect and there's no weakness compared to surgical treatment. But there was an increase in danger of complications. The key of conservative treatment lies in early diagnosis and maintenance of reduction, reliable fixation, and timely and appropriate functional exercise. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.
Ahmed, Mohammed M; Otto, Thomas J; Moed, Berton R
2016-04-22
Limited-incision total hip arthroplasty (THA) preserves hip abductors, posterior capsule, and external rotators potentially diminishing dislocation risk. However, potential complications also exist, such as component malposition. Specific implants have been manufactured that enhance compatibility with this technique, while preserving metaphyseal bone; however, little data exists documenting early complications and component position. The purpose was to evaluate primary THA using a curved, bone-sparing stem inserted through the anterior approach with respect to component alignment and early complications. In a retrospective analysis of 108 cases, the surgical technique was outlined and the occurrence of intraoperative fractures, postoperative dislocations, infection, and limb length inequality was determined. Femoral stem and acetabular cup alignment was quantified using the initial postoperative radiographs. Patient follow-up averaged 12.9 (range 2 to 36) months. There were eight (7.4 %) complications requiring revision surgery in three (2.8 %) patients with three (2.8 %) infections and three (2.8 %) dislocations. Intraoperative complications included one calcar fracture above the lesser trochanter. Leg length inequality >5 mm was present in three (2.8 %) patients. Radiographic analysis showed that femoral neutral alignment was achieved in 95 hips (88.0 %). All femoral stems demonstrated satisfactory fit and fill and no evidence of subsidence, osteolysis, or loosening. An average abduction angle of 44.8° (± 5.3) and average cup anteversion of 16.2° (± 4.2) were also noted. Although the technique with this implant and approach is promising, it does not appear to offer important advantages over standard techniques. However, the findings merit further, long-term study.
Satisfactory results at 8 years mean follow-up after ADVANCE® medial-pivot total knee arthroplasty.
Chinzei, Nobuaki; Ishida, Kazunari; Tsumura, Nobuhiro; Matsumoto, Tomoyuki; Kitagawa, Atsushi; Iguchi, Tetsuhiro; Nishida, Kotaro; Akisue, Toshihiro; Kuroda, Ryosuke; Kurosaka, Masahiro
2014-03-01
Although good overall results have been reported with TKA, certain problems and limitations remain, primarily due to postoperative differences in joint kinematics, when compared with the normal knee. ADVANCE® Medial-Pivot TKA involves replicating the medial pivoting behavior observed in normal knees. Here, we aimed to investigate the clinical and radiological results and complications of TKA using this implant, at mid-term follow-up. From January 2001 to March 2012, we retrospectively selected 76 patients (85 knees; mean age at operation, 70.2±8.1 years; range, 51-88 years) with a mean follow-up period of 93.1±14.3 months (range, 72-132 months). Indications for TKA included primary degenerative osteoarthritis (60 knees), rheumatoid arthritis (22 knees), osteonecrosis (two knees), and osteoarthritis following high tibial osteotomy (one knee). The clinical and radiographic results were evaluated. Kaplan-Meier survivorship analysis indicated a success rate of 98.3% (95% confidence interval, 96.6-99.9%). Comparison of pre- and postoperative knee extension angles and ranges of motion showed significant improvement postoperatively, in both the Knee Society Scores (KSS) and Knee Society Functional Scores (KSFS) (p<0.05). In one case, radiographic assessment indicated implant loosening due to infection; however, despite this complication, significant improvement of postoperative varus or valgus deformity angles were noted in all cases (p<0.05). Patients undergoing ADVANCE® Medial-Pivot TKA achieved excellent clinical and radiographic results without any implant-related failures at mid-term follow-up. Level IV. © 2013.
Multimodal analgesia without parenteral narcotics for total knee arthroplasty.
Dorr, Lawrence D; Raya, Julio; Long, William T; Boutary, Myriam; Sirianni, Leigh Ellen
2008-06-01
Use of parenteral narcotics after total knee arthroplasty is considered by most orthopedic surgeons to be the standard of care. This study tested the hypothesis that a multimodal oral pain medication protocol could control pain and minimize complications of parenteral narcotics. Postoperative oral analgesia was augmented with either continuous epidural infusion or continuous femoral infusion using ropivacaine only. Seventy patients had total knee arthroplasty with a protocol that included preemptive oral analgesics, epidural anesthesia, pericapsular analgesic injection, and postoperative analgesia without parenteral opioids. The average daily pain score was less than 4 out of 10, nausea occurred in 15 patients (21%), emesis in 1 patient (1.4%), and there were no severe complications. This study proved the hypothesis that pain after total knee arthroplasty could be effectively managed without routine use of parenteral opioids.
2018-06-07
Surgical Wound; Revision Total Knee Arthroplasty; Wounds and Injuries; Joint Disease; Musculoskeletal Disease; Prosthesis-Related Infections; Infection; Postoperative Complications; Pathologic Processes
Knee arthrodesis with circular external fixation.
Garberina, M J; Fitch, R D; Hoffmann, E D; Hardaker, W T; Vail, T P; Scully, S P
2001-01-01
Knee arthrodesis can enable limb salvage in patients with disability secondary to trauma, infected total knee arthroplasty, pyarthrosis, and other complications. Historically, intramedullary nailing has resulted in the highest overall knee fusion rates. However, intramedullary nailing is relatively contraindicated in the presence of active infection. Nineteen patients who underwent knee arthrodesis with circular external fixation were studied retrospectively. Postoperative radiographs were evaluated for evidence of bony fusion, which was defined as trabecular bridging between the femur and tibia. Patients were interviewed and graded using the functional assessment portion of the Knee Society clinical rating system. Fusion was successful in 13 of 19 (68%) patients. Overall, patients spent an average of 4 months 8 days wearing the circular external fixator. Average time to radiographic and clinical evidence of arthrodesis (defined as lack of motion across the fusion site) was 4 months 18 days. No patient with successful fusion considered himself or herself housebound. All but one of these patients require some form of assistive device for ambulation. Complications occurred in 16 of 19 (84%) patients overall. Superficial pin tract infection (55%) and nonunion (32%) were the most common. Circular external fixation is an effective method for obtaining knee arthrodesis in patients who are not good candidates for intramedullary nailing.
Hemi-wedge osteotomy in the management of large angular deformities around the knee joint.
El-Alfy, Barakat Sayed
2016-08-01
Angular deformity around the knee joint is a common orthopedic problem. Many options are available for the management of such problem with varying degrees of success and failure. The aim of the present study was to assess the results of hemi-wedge osteotomy in the management of big angular deformities about the knee joint. Twenty-eight limbs in 21 patients with large angular deformities around the knee joint were treated by the hemi-wedge osteotomy technique. The ages ranged from 12 to 43 years with an average of 19.8 years. The deformity ranged from 20° to 40° with a mean of 30.39° ± 5.99°. The deformities were genu varum in 12 cases and genu valgum in 9 cases. Seven cases had bilateral deformities. Small wedge was removed from the convex side of the bone and put in the gap created in the other side after correction of the deformity. At the final follow-up, the deformity was corrected in all cases except two. Full range of knee movement was regained in all cases. The complications included superficial wound infection in two cases, overcorrection in one case, pain along the lateral aspect of the knee in one case and recurrence of the deformity in one case. No cases were complicated by nerve injury or vascular injury. Hemi-wedge osteotomy is a good method for treatment of deformities around the knee joint. It can correct large angular deformities without major complications.
Thromboembolic diseases and the use of vena cava filters.
De Silva, Samanthi
2017-04-01
Mr GW is a 77-year-old gentleman who is hoping to have a total knee replacement of his left knee. He underwent a knee replacement on the right in 2011 under spinal anaesthetic, where his postoperative period was complicated by a saddle pulmonary embolus (PE). Copyright the Association for Perioperative Practice.
Fatal fat embolism syndrome in a case of isolated L1 vertebral fracture-dislocation.
Yamauchi, Koun; Fushimi, Kazunari; Ikeda, Tsuneko; Fukuta, Masashi
2013-11-01
Although fat embolism syndrome is a well-known complication of fractures of the long bones or pelvis, fat embolism syndrome occurring subsequent to fracture of the lumbar spine is rare. We report a fatal case of fat embolism syndrome characterized by fat and bone marrow embolism that occurred 36 h after an isolated fracture-dislocation of the L1 vertebra. A postmortem examination was performed and pathological finding demonstrated fat and bone marrow tissue which were disseminated in the bilateral pulmonary arteries. We need to be aware of the possibility of fat embolism syndrome as a complication of spinal fractures, including isolated vertebral body fractures.
Chang, Hung-Yu; Man, Kee-Ming; Liao, Kate Hsiurong; Chiang, Yi-Ying; Chen, Kuen-Bao
2017-09-01
Airway stenting is a well-established method that relieves symptoms and maintains airway patency in patients with airway obstruction. Serious complications caused by airway stents such as stent dislocation and airway obstruction during surgery are life-threatening. An 80-year-old man was treated with bronchial stent for left bronchus obstruction caused by metastatic esophageal cancer. During tracheostomy surgery, he suffered from acute tracheal obstruction caused by dislocated bronchial stent. Esophageal cancer, left bronchus obstruction, respiratory failure, tracheal obstruction. Threading a 5.0-sized endotracheal tube combined with an Eschmann tracheal tube introducer to prop up the collapsed stent. The bronchial stent was re-expanded and threaded into right main bronchus and ventilation restored. Patient with airway stent undergoing surgery with airway involved should be performed under the support of a backup physician and equipment that are capable of handling potentially life-threatening complications of airway stent. If not, in the emergent situation of tracheal obstruction due to tracheal/bronchial stent, protruding through the stent with a suitable, small-sized endotracheal tube with Eschmann tracheal tube introducer may be an alternative skill for saving life weighted with possible complications.
Sobhan, Mohammad R; Abrisham, Seyed Mohammad J; Vakili, Mahmood; Shirdel, Saeed
2016-10-01
Pelvic ring injuries and sacroiliac dislocations have significant impacts on patient's quality of life. Several techniques have been described for posterior pelvic fixation. The current study has been designed to evaluate the spinopelvic method of fixation for sacroiliac fractures and fracture-dislocations. Between January 2006 and December 2014, 14 patients with sacroiliac joint fractures, dislocation and fracture-dislocation were treated by Spinopelvic fixation at Shahid Sadoughi Training Hospital, Yazd, Iran. Patients were seen in follow up, on average, out to 32 months after surgery. Computed tomographic (CT) scans of patients with sacral fractures were reviewed to determine the presence of injuries. A functional assessment of the patients was performed using Majeed's score. Patient demographics, reduction quality, loss of fixation, outcomes and complications, return to activity, and screw hardware characteristics are described. The injury was unilateral in 11 (78.5%) patients and bilateral in 3 (21.5%). Associated injuries were present in all patients, including fractures, dislocation and abdominal injuries. Lower limb length discrepancy was less than 10 mm in all patients except two. Displacement, as a measure of quality of reduction was less than 5 mm in 13 patients. The mean Majeed score was 78/100. Wound infection and hardware failure were observed in 3 (21.4%) and 1 (7.1%) cases, respectively. In this study most patients (85%) return to work postoperatively. According to the findings, spinopelvic fixation is a safe and effective technique for treatment of sacroiliac injuries. This method can obtain early partial to full weight bearing and possibly reduce the complications.
Baden, David N; Roetman, Martijn H; Boeije, Tom; Roodheuvel, Floris; Mullaart-Jansen, Nieke; Peeters, Suzanne; Burg, Mike D
2017-07-20
Glenohumeral (shoulder) dislocations are the most common large joint dislocations seen in the emergency department (ED). They cause pain, often severe, and require timely interventions to minimise discomfort and tissue damage. Commonly used reposition or relocation techniques often involve traction and/or leverage. These techniques have high success rates but may be painful and time consuming. They may also cause complications. Recently, other techniques-the biomechanical reposition techniques (BRTs)-have become more popular since they may cause less pain, require less time and cause fewer complications. To our knowledge, no research exists comparing the various BRTs. Our objective is to establish which BRT or BRT combination is fastest, least painful and associated with the lowest complication rate for adult ED patients with anterior glenohumeral dislocations (AGDs). Adults presenting to the participating EDs with isolated AGDs, as determined by radiographs, will be randomised to one of three BRTs: Cunningham, modified Milch or scapular manipulation. Main study parameters/endpoints are ED length of stay and patients' self-report of pain. Secondary study parameters/endpoints are procedure times, need for analgesic and/or sedative medications, iatrogenic complications and rates of successful reduction. Non-biomechanical AGD repositioning techniques based on traction and/or leverage are inherently painful and potentially harmful. We believe that the three BRTs used in this study are more physiological, more patient friendly, less likely to cause pain, more time efficient and less likely to produce complications. By comparing these three techniques, we hope to improve the care provided to adults with acute AGDs by reducing their ED length of stay and minimising pain and procedure-related complications. We also hope to define which of the three BRTs is quickest, most likely to be successful and least likely to require sedative or analgesic medications to achieve reduction. NTR5839. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Treatment and evolution of grade III acromioclavicular dislocations in soccer players.
Pereira-Graterol, Ernesto; Álvarez-Díaz, Pedro; Seijas, Roberto; Ares, Oscar; Cuscó, Xavier; Cugat, Ramón
2013-07-01
To evaluate postoperative functional results in soccer players diagnosed with acute grade III acromioclavicular dislocation, stabilized with clavicular hook plate. Between 2006 and 2010, 11 soccer players were diagnosed with acute acromioclavicular dislocation. Mean age was 22.9 years. The clavicular hook plate was used for stabilization. The follow-up was 4 years (2-6 years). Constant score showed 82 % excellent results and 18 % good functional results. Average pain measured with VAS was 1.8 (±0.59) mm out of 10. We did not report any complication within the process. Use of the clavicular hook plate is considered adequate for the treatment of acute acromioclavicular dislocation in soccer players, allowing a quick return to sports. Retrospective case series, Level IV.
Saini, Pramod; Meena, Sanjay; Malhotra, Rajesh; Gamanagatti, Shivanand; Kumar, Vijay; Jain, Vaibhav
2013-01-01
Pseudoaneurysm of superior lateral genicular artery following total knee arthroplasty is a rare complication and has been reported following lateral release performed for eversion of patella in a knee with tight lateral structures. This report describes a case of pseudo aneurysm of superior lateral geniculate artery that developed after primary Total knee arthroplasty for a stiff knee in a 68 year old patient. Patient presented with pain and rapidly increasing swelling in early post operative period. Diagnosis was made on duplex ultrasound and confirmed by angiography. Angiographic coil embolisation of the pseudoaneurysm was performed. Since no lateral release was performed in this case, the probable mechanism was shear injury to the vessel. Pseudoaneurysm of superior lateral genicular artery can occur in absence of lateral release by shear injury to an atherosclerotic vessel. Angiographic coil embolisation appears to be the best method for treating such post arthroplasty pseudoaneurysm because of less chance of infection, non interference with rehabilitation and diagnosis and treatment during same procedure.
Traumatic hip dislocation at a regional trauma centre in Nigeria.
Onyemaechi, N O C; Eyichukwu, G O
2011-01-01
Traumatic dislocation or fracture-dislocation of the hip is an orthopaedic emergency that is steadily increasing in incidence due to high-speed motor vehicular accidents. These injuries need to be recognized early and promptly treated to prevent morbidity and long-term complications. Some of the fundamental issues in the management of traumatic dislocations of the hip are the critical interval between injury and reduction, the type of reduction most suitable for various types of injury and the duration of immobilization that give the best results. This study was carried out at the National Orthopaedic Hospital Enugu, a regional trauma and orthopaedic centre in South-East Nigeria. The purpose of the study is to describe the pattern of presentation and to identify the factors that determine the long-term outcome in the treatment of traumatic dislocations and fracture-dislocations of the hip at Enugu, Nigeria. The case notes of all the patients that presented with traumatic dislocations and fracture-dislocations of the hip between January 2003 and December 2007 were reviewed. The information extracted and analyzed included the patients' demographics, etiology of injury, time interval before reduction, associated injuries, treatment offered, complications and follow-up. Thompson-Epstein classification was used to grade the posterior hip dislocations. The outcome of treatment was evaluated using the clinical and radiological criteria proposed by Epstein (1974). Three patients with incomplete data and two patients with central fracture dislocation were excluded from this study. Forty-eight patients with 50 hip dislocations were analyzed. The age range was 12 years to 67 years with a mean age of 34.8 years. Thirty-nine patients (81.3%) were males and 9 (18.7%) were females. Road-traffic accident was the leading cause of traumatic hip dislocation in this series, 44 cases (91.6%). Posterior dislocation occurred in 48 hips (96%) while anterior dislocation occurred in 2 hips (4%). Forty-seven hips (94%) were treated by primary closed reduction, two hips (4%) were treated with open reduction and one patient (2%) had Girdlestone excision arthroplasty. Thirty-six hips (73.5%) were reduced with 12 hours of the injury. Concomitant injuries were found in 37 patients (77%). The follow up period ranged from 10 months to 36 months with a mean follow up period of 15 months. Post-traumatic osteoarthritis occurred in 2 hips (4%) avascular necrosis of the femoral head was seen in 2 hips (4%). Five patients had sciatic nerve paresis while there was recurrence in one hip. No mortality was recorded. Traumatic dislocations and fracture-dislocations of the hip are severe injuries caused mostly by high-speed motor-vehicular accidents. Young adult males are most commonly affected, and there is a high rate of concomitant injuries. Excellent results can be achieved by early and stable closed reduction of these injuries with immobilization of the affected hips.
[Intra-prosthetic dislocation of the Bousquet dual mobility socket].
Lecuire, F; Benareau, I; Rubini, J; Basso, M
2004-05-01
The Bousquet system is a dual mobility head-polyethylene polyethylene-metal cup socket. The polyethylene insert retaining the femoral head moves in the noncemented metal cup, increasing both mobility and stability. Between 1989 and 1997, seven cases of intra-prosthetic dislocation (six patients) were observed. The femoral head escaped from the polyethylene insert due to wear. On the average, this complication occurred ten Years after implantation. Risk of dislocation was high in six of the seven hips. All patients had a large sized stem screwed into the femoral neck. There was a characteristic radiological aspect with loss of the concentric head metal cup configuration. The head was applied against the upper wall of the metal cup. Surgical replacement was undertaken early in six patients by simply changing the insert without modifying the other stable components. Outcome remained good at three to eight Years. One patient underwent late surgery. The insert and the cup were replaced with a classical implant. Functional outcome was good but recurrent dislocation occurred. At mid-term, intra-prosthetic dislocation of dual mobility sockets appears to be exceptional. Dislocation results from polyethylene wear leading to failure of the insert to retain the prosthetic head. Wear is favored by direct phenomena (direct contact between neck and insert which can occur early if there is a small difference in the head and neck diameters) or indirect phenomena (factors limiting polyethylene metal-cup mobility). Surgical treatment is necessary. If undertaken early, replacement with a modular head and insert can be sufficient if the prosthesis has not loosened but the metal cup may have to be replaced in the event of metal-metal contact between the head and the cup. Prosthesis loosening, wear of the metal cup, or an identified cause of dislocation imply replacing the failing implants. Implantation of the dual mobility system is particularly interesting for patients with a high risk of dislocation or a chronically unstable hip prosthesis. Careful technique is required to reduce or retard the risk of intra-prosthetic dislocation. Intra-prosthetic dislocation of a dual mobility socket is an exceptional complication at mid-term. Surgical treatment is required but may be limited to simple insert replacement. Systematic use of this type of implant in young subjects must be carefully examined, but for us, the risk of dislocation does not outweigh the advantages of this original concept of dual mobility. This type of socket remains an useful preventive technique for high-risk hips or for curative treatment of recurrent dislocation.
Guan, Ting-Jin; Sun, Peng; Zheng, Liang-Guo; Qi, Xiang-Yang
2014-01-01
To study measurement methods of acromioclavicular and coracoclavicular ligament injuries,its therapeutic effects and complications during internal fixation operation for the treatment of fresh acromioclavicular joint dislocations of Tossy type III. From July 2003 to May 2012,127 patients with acromioclavicular joint dislocations of Tossy type III were treated with wire fixation from coracoid process to clavicle or hook-plate fixation. The patients were divided into group A (63 cases) and group B (64 cases) according to whether acromioclavicular ligament and coracoclavicular ligament were repaired or not. In group A (ligaments repaired), there were 39 males and 24 females with an average age of (33.25 +/- 8.46) years old (ranged from 17 to 59 years). And in group B (no ligaments repaired), there were 41 males and 23 females with an average age of (34.10 +/- 7.19) years (ranged from 19 to 57 years). The operation times, intraoperative blood loss, postoperative infections, internal fixation failure, recurrence and other complications, together with therapeutic effects were compared between two groups. The outcome was analyzed according to Karlsson standard. In group A, 54 patients got an excellent result and 9 good according to Karlsson standard;the average operative time was (55.90 +/- 26.56) min; the average intraoperative bleeding amount was (99.80 +/- 50.30) ml; 1 patient had wire broken without re-dislocation at 16 weeks after operation, 3 patients got wound fat liquefaction and recovered after treatment, 1 patient had pain after shoulder joint motion and pain disappeared after implants were taken out. In group B, 52 patients got an excellent result and 12 good according to Karlsson standard; the average operative time was (49.50 +/- 23.14) min; the average intraoperative bleeding amount was (87.30 +/- 46.41) ml; 2 patients got wound fat liquefaction, and 2 patients had pain after shoulder joint motion. All the patients were followed up, and the duration ranged from 9 to 16 months. All internal steel-wire or hook plate were taken out during 4 to 9 months without acromioclavicular joint re dislocation. There were no significant difference in the average operative time, the average intraoperative blood less, complication recurrence rates of fixation failure, wound fat liquefaction, postoperative infection, acromioclavicular joint re-dislocation, and therapeutic effects between two groups. Both wire and clavicular hook plate fixation, performed for fresh acromioclavicular joint dislocation with Tossy type III, are simple, effective, less invasive method with less blood loss. In addition, the treatment without ligaments repaired could not increase incidence of complications.
U.S. Navy Aeromedical Reference and Waiver Guide
2010-05-05
Disc Disease 13.5 Knees: Ligament/Meniscal Tears 13.6 Orthopedic Hardware Retained 13.7 Recurrent Shoulder Dislocation 13.8 Spinal Fractures 13.9...therapy or facial fracture . See MMD paragraph 15-95 or Physical Exam section of ARWG for text. U.S. Navy Aeromedical Reference and Waiver Guide... fracture . See MMD paragraph 15-95 or Physical Exam section of ARWG for text. U.S. Navy Aeromedical Reference and Waiver Guide Physical
Injury Prevention and Performance Enhancement in 101st Airbourne Soldiers
2012-02-01
those of elite athletes, with similar performance and nutrition needs. Dietary recommendations have been developed for the optimal amount of...2005. 33(3): p. 415-23. 10. Alonso AC, Greve JM, and Camanho GL: Evaluating the center of gravity of dislocations in soccer players with and without...Pietila T, and Werner S: Risk factors for leg injuries in female soccer players : a prospective investigation during one out-door season. Knee Surg
[Shoulder instability and rotator cuff tear].
Voigt, C; Lill, H
2009-01-01
A rotator cuff tear as a complication of anterior shoulder dislocation is well known in patients over 40 years old. The incidence of this accompanying injury correlates with the patient's age and the number of redislocations. The tear localization and dimension depend on the patient's age. To what extent these tears are a complication of shoulder dislocation is often unclear, as rotator cuff tears and glenohumeral instability interact. Reports on this combined injury pattern are rare, but based on the patient's age, activity level, and functional demand, therapeutic concepts have been devised. In active patients younger than 60 years and in cases of redislocation, both the rotator cuff tear and the capsule-labrum-ligament lesion should be reconstructed arthroscopically. In lesser active patients age 60 years or older, an isolated rotator cuff reconstruction is often sufficient to stabilize the glenohumeral joint. This treatment concept shows a predominantly good outcome.As a special form of anterior shoulder dislocation, a rotator cuff tear and a plexus brachialis lesion--the"terrible triad of the shoulder"--is described here.
Ricci, R Daniel; Cerullo, James; Blanc, Robert O; McMahon, Patrick J; Buoncritiani, Anthony M; Stone, David A; Fu, Freddie H
2008-01-01
Objective: To present the case of a talocrural dislocation with a Weber type C fibular fracture in a National Collegiate Athletic Association Division I football athlete. Background: The athlete, while attempting to make a tackle during a game, collided with an opponent, who in turn stepped on the lateral aspect of the athlete's ankle, resulting in forced ankle eversion and external rotation. On-field evaluation showed a laterally displaced talocrural dislocation. Immediate reduction was performed in the athletic training room to maintain skin integrity. Post-reduction radiographs revealed a Weber type C fibular fracture and increased medial joint clear space. A below-knee, fiberglass splint was applied to stabilize the ankle joint complex. Differential Diagnosis: Subtalar dislocation, Maisonneuve fracture, malleolar fracture, deltoid ligament rupture, syndesmosis disruption. Treatment: The sports medicine staff immediately splinted and transported the athlete to the athletic training room to reduce the dislocation. The athlete then underwent an open reduction and internal fixation procedure to stabilize the injury: 2 syndesmosis screws and a fibular plate were placed to keep the ankle joint in an anatomically reduced position. With the guidance of the athletic training staff, the athlete underwent an accelerated physical rehabilitation protocol in an effort to return to sport as quickly and safely as possible. Uniqueness: Most talocrural dislocations and associated Weber type C fibular fractures are due to motor vehicle accidents or falls. We are the first to describe this injury in a Division I football player and to present a general rehabilitation protocol for a high-level athlete. Conclusions: Sports medicine practitioners must recognize that this injury can occur in the athletic environment. Prompt reduction, early surgical intervention, sufficient resources, and an accelerated rehabilitation protocol all contributed to a successful outcome in the patient. PMID:18523569
Design comparison: manipulation after total knee arthroplasty.
Rogers, Jason M; Patel, Kevin V; Barnes, C Lowry
2015-01-01
Postoperative stiffness is a relatively uncommon issue in total knee arthroplasty (TKA). However, it can be a debilitating complication when it occurs. Manipulation under anesthesia (MUA) is commonly used as the primary treatment modality following failed physiotherapy. The Advance medial pivot knee (Wright Medical Technology) was created in an effort to prevent stiffness postoperatively and increase range of motion. The Evolution medial pivot knee is a second-generation design that builds on the technology of the Advance knee. This article presents a retrospective review of prospectively collected data on 881 primary medial pivot knees (592 Advance knees, 289 Evolution knees). It was theorized that the design changes made to the Evolution knees might contribute toward reducing the need for MUA. It was found that the Evolution knees required significantly fewer manipulations under anesthesia (p = .036). The design modifications made to the Evolution knees may have contributed to the lower rate of MUA.
Outcome following total knee arthroplasty in obese versus non-obese Asian patients.
Goh, Graham Seow-Hng; Liow, Ming Han Lincoln; Mitra, Amit Kanta
2015-12-01
To compare the outcome following total knee arthroplasty (TKA) in obese and non-obese Asian patients. 27 obese patients were compared with 27 non-obese controls matched for age, gender, diagnosis (osteoarthritis), prosthesis, preoperative Knee Society knee and function scores, preoperative Oxford Knee Score, and follow-up duration. All TKAs were performed by a single surgeon. Patients were assessed at 6 months and 2 years for the range of motion, Knee Society knee and function scores, Oxford Knee Score, and Short Form-36 Health Survey (SF-36). The obese and non-obese groups did not differ significantly in pre- and post-operative variables: range of motion, Knee Society knee and function scores, Oxford Knee Score, and SF-36 score. Using revision as an end-point, implant survival was 100%. There were no intra- or post-operative complications in either group. Obese and non-obese Asian patients achieved a comparable outcome following TKA.
Nakamura, Shinichiro; Sharma, Adrija; Kobayashi, Masahiko; Ito, Hiromu; Nakamura, Kenji; Zingde, Sumesh M; Nakamura, Takashi; Komistek, Richard D
2014-01-01
Kneeling position can serve as an important posture, providing stability and balance from a standing position to sitting on the floor or vice-versa. The purpose of the current study was to determine the kinematics during kneeling activities after subjects were implanted with a tri-condylar total knee arthroplasty. Kinematics was evaluated in 54 knees using fluoroscopy and a three-dimensional model fitting approach. The average knee flexion at before contact status, at complete contact and at maximum flexion was 98.1±9.0°, 107.2±6.7°, and 139.6±12.3°, respectively. On average, there was no gross anterior displacement from before contact status to complete contact. Only slight posterior rollback motion of both condyles from complete contact to maximum flexion was observed. Three of 39 (7.7%) knees experienced anterior movement of both condyles more than 2mm from before contact status to complete contact. Reverse rotation pattern from before contact status to complete contact and then normal rotation pattern from complete contact to maximum flexion were observed. Condylar lift-off greater than 1.0 mm was observed in 45 knees (83.3%). The presence of the ball-and-socket joint articulation provides sufficient antero-posterior stability in these designs to enable the patients to kneel safely without the incidence of any dislocation. This study suggests a safe implant design for kneeling. © 2013.
Bin Abd Razak, Hamid Rahmatullah; Yeo, Eng-Meng Nicholas; Yeo, William; Lie, Tijauw-Tjoen Denny
2018-07-01
The aim of this study was to compare the short-term outcomes of arthroscopic TightRope ® fixation with that of hook plate fixation in patients with acute unstable acromioclavicular joint dislocations. We conducted a prospective case-control study of twenty-six patients with an acute ACJ dislocation who underwent surgical repair with either an arthroscopic TightRope ® fixation or a hook plate from 2013 to 2016. Clinical and radiological data were collected prospectively. Clinical outcomes were evaluated using the Constant Score, the University of California at Los Angeles (UCLA) Shoulder Score, Oxford Shoulder Score as well as the visual analogue scale. Radiological outcomes were assessed with the coracoclavicular distance (CCD). Sixteen patients underwent arthroscopic TightRope ® fixation, while 10 patients underwent hook plate fixation. There were no significant differences in the preoperative variables except for the mean UCLA 4b infraspinatus score (TightRope ® 2.8 vs. hook plate 3.8; p = 0.030). Duration of surgery was significantly longer in the TightRope ® group. At 1 year post-operatively, the TightRope ® group had a significantly better Constant Score and CCD with no complications. All patients with hook plate fixation had to undergo a second procedure for removal of implant, and 3 patients had complications. Arthroscopic TightRope ® fixation is a good option for the treatment of acute unstable ACJ dislocations. It has better short-term clinical and radiological outcomes as well as lesser complications when compared to hook plate fixation. Therapeutic, Level III.
Moura, Diogo Lino; Reis E Reis, Augusto; Ferreira, João; Capelão, Manuel; Braz Cardoso, José
2018-01-01
This study aims to describe the surgical approach to such injuries and to present the clinical and functional outcomes obtained in a cohort of patients. This is an observational retrospective study that included 153 patients with acute acromioclavicular joint dislocation, operated between 1999 and 2015. Clinical evaluation included the following outcomes: Constant functional scale, development of complications, time to return to previous work/sport activities, and satisfaction index. The contra-lateral (uninjured) shoulder was used as control in subjective outcomes. Radiological evaluation was performed in order to monitor signs of loss of reduction, degenerative joint changes, and coracoclavicular calcifications. The mean age was 29.20 ± 9.53 (16-71), with a large male predominance (91.5%). Follow-up lasted 55.41 ± 24.87 (12-108) months. The mean Constant score attained was 96.45 ± 4.00 (84-100) on operated shoulders and 98.28 ± 1.81 (93-100) on contralateral ones. Almost all patients (98.69%) were satisfied with the surgical results. Worse outcomes were observed in acromioclavicular joint dislocations of increasing grade (from type III to V, but worse for type IV), both concerning the Constant score and return to work or sport. The overall incidence of complications was considered low, with the most prevalent being Kirschner wire failure and isolated coracoclavicular ligament calcifications. The surgical technique described is an excellent option in the treatment of acute acromioclavicular joint dislocations of Rockwood grades III to V. This is corroborated by the excellent clinical and functional outcomes and the low rate of complications.
Nakano-Matsuoka, Natsuko; Fukiage, Kenichi; Harada, Yuki; Kashiwagi, Naoya; Futami, Tohru
2017-11-01
The aim of this study is to evaluate the complications of humeral lengthening and their associated factors. Fifty-four achondroplastic patients were treated by bilateral humeral lengthening. Our original shoulder sling was sufficient to prevent shoulder dislocation. Pre-existing radial head dislocation was observed in 18 patients. Lengthening was accomplished in all cases without a decrease in the elbow function. Seven humeri fractured after the fixator removal. The risk factors for postoperative fracture were a waiting period of less than 5 days, a healing index less than 25, and the concave shape of the callus. There was no radial nerve palsy.
Şükür, Erhan; Öztürkmen, Yusuf; Akman, Yunus Emre; Senel, Ahmet; Azboy, İbrahim
2016-12-01
There is no consensus on the position of the knee joint while performing wound closure after total knee arthroplasty (TKA). Further, there are no studies focusing on the association between early functional outcomes and different wound closure strategies. Therefore, we investigated the effects of tourniquet and knee position during wound closure on early recovery of range of motion (ROM) after primary TKA. To our knowledge, this is the first study to evaluate the influence of both tourniquet and knee position during wound closure in primary TKA. One hundred-twenty eligible patients were consecutively enrolled in this study and randomly divided into four groups according to wound closure strategy. Wound closure was either performed with the knee in flexion at 90° or in full extension, with the combination of an inflated or deflated tourniquet. Visual analogue score (VAS), knee ROM, ROM recovery, knee society score (KSS), and wound complications were evaluated in the early postoperative period. After the first postoperative week, ROM recovery in the group with knee in extension and inflated tourniquet was significantly lesser than the two groups with deflated tourniquets. Between the first and fourth postoperative weeks, ROM recovery in the group with knee inflection and deflated tourniquet was significantly higher than the two groups with knee in extension. After the first postoperative week, the visual analog score (VAS) for pain in the group with knee inflection and deflated tourniquet was significantly lesser than the two groups with inflated tourniquets. The differences in the outcomes between the four groups were not significant after the fourth postoperative week. The incidence of wound complications and KSS were not significantly different between the four groups. Following TKA, wound closure with the knee in flexion and after deflating the tourniquet significantly decreased postoperative pain and promoted the recovery of ROM in the early postoperative period.
Sanders, Thomas L; Johnson, Nick R; Pareek, Ayoosh; Krych, Aaron J; Marx, Robert G; Stuart, Michael J; Levy, Bruce A
2018-04-01
Increasing importance has been placed on the posterolateral corner (PLC) in maintaining varus and rotational stability of the knee. The goal of this study was to evaluate knee function and clinical stability following a single-graft PLC reconstruction technique and identify factors associated with poor knee function. This study identified patients with a multi-ligament knee injury between 2006 and 2013. Patients who received a single-graft fibular collateral ligament and PLC reconstruction with a single-stage surgery during the study period and had a minimum follow-up of 2 years after surgery were included. Functional outcomes were assessed using Lysholm and IKDC scores. Varus and rotational knee laxity and range of motion were assessed using physical examination. The final study cohort included 61 patients who underwent PLC reconstruction using a single-graft technique. The mean IKDC score was 74.1 (± 22.3) and the mean Lysholm score was 80.3 (± 21.8) at mean follow-up of 3.8 years (range 2-9 years). Mean range of motion at final follow-up measured from 0° to 126° [range flexion: 95-145, range extension: 0-5]. Fifty-eight patients (95%) had grade 0 varus laxity in full knee extension, and 54 patients (88.5%) had grade 0 varus laxity at 30° of knee flexion. Female gender was associated with a lower postoperative IKDC score (p = 0.04). Surgical treatment of the PLC using a single-graft technique can result in satisfactory knee function and stable physical examination findings at minimum 2 years after surgery. Female gender was predictive of poor knee function after PLC reconstruction. Surgical treatment of PLC injuries should be individualized based on the timing of surgery, specific injured knee structures, and physical examination findings. This study helps validate the use of a single-graft technique for PLC reconstruction and can be used to help counsel patients about expected knee function after surgical treatment of PLC injuries. Level of evidence IV.
Finite element analysis of unicompartmental knee arthroplasty.
Hopkins, Andrew R; New, Andrew M; Rodriguez-y-Baena, Ferdinando; Taylor, Mark
2010-01-01
Concerns over accelerated damage to the untreated compartment of the knee following unicompartmental knee arthroplasty (UKA), as well as the relatively poor success rates observed for lateral as opposed to the medial arthroplasty, remain issues for attention. Finite element analysis (FEA) was used to assess changes to the kinematics and potential for cartilage damage across the knee joint in response to the implantation of the Oxford Mobile Bearing UKA. FE models of lateral and medial compartment arthroplasty were developed, in addition to a healthy natural knee model, to gauge changes incurred through the arthroplasty. Varus-valgus misalignments were introduced to the femoral components to simulate surgical inaccuracy or over-correction. Boundary conditions from the Stanmore knee simulator during the stance phase of level gait were used. AP translations of the tibia in the medial UKA models were comparable to the behaviour of the natural knee models (+/-0.6mm deviation from pre-operative motion). Following lateral UKA, 4.1mm additional posterior translation of the tibia was recorded than predicted for the natural knee. IE rotations of the medial UKA models were less consistent with the pre-operative knee model than the lateral UKA models (7.7 degrees vs. 3.6 degrees deviation). Varus misalignment of the femoral prosthesis was more influential than valgus for medial UKA kinematics, whereas in lateral UKA, a valgus misalignment of the femoral prosthesis was most influential on the kinematics. Resection of the cartilage in the medial compartment reduced the overall risk of progressive OA in the knee, whereas removing the cartilage from the lateral compartment, and in particular introducing a valgus femoral misalignment, increased the overall risk of progressive OA in the knee. Based on these results, under the conditions tested herein, both medial and lateral UKA can be said to induce kinematics of the knee which could be considered broadly comparable to those of the natural knee, and that even a 10 degrees varus-valgus misalignment of the femoral component may not induce highly irregular kinematics. However, elevated posterior translation of the tibia in lateral UKA and large excursions of the insert may explain the higher incidence of bearing dislocation observed in some clinical studies. (c) 2009 IPEM. All rights reserved.
Wang, Hao; Shen, Bin; Zeng, Yi
2014-12-01
There has been much debate and controversy about the optimal regimen of tranexamic acid in primary total knee arthroplasty. The purpose of this study was to undertake a meta-analysis to compare the efficacy of topical and intravenous regimen of tranexamic acid in primary total knee arthroplasty. A systematic review of the electronic databases PubMed, CENTRAL, Web of Science, and Embase was undertaken. All randomized controlled trials and prospective cohort studies evaluating the effectiveness of topical and intravenous tranexamic acid during primary total knee arthroplasty were included. The focus of the analysis was on the outcomes of blood loss, transfusion rate, and thromboembolic complications. Subgroup analysis was performed when possible. Of 328 papers identified, six trials were eligible for data extraction and meta-analysis comprising 679 patients (739 knees). We found no statistically significant difference between topical and intravenous administration of tranexamic acid in terms of blood loss, transfusion requirements and thromboembolic complications. Topical tranexamic acid has a similar efficacy to intravenous tranexamic acid in reducing both blood loss and transfusion rate without sacrificing safety in primary total knee arthroplasty. II. Copyright © 2014 Elsevier B.V. All rights reserved.
Yamanaka, Hajime; Goto, Ken-ichiro; Suzuki, Munetaka
2012-02-22
Total knee arthroplasty (TKA) is a common form of treatment to relieve pain and improve function in cases of rheumatoid arthritis (RA). Good clinical outcomes have been reported with a variety of TKA prostheses. The cementless Hi-Tech Knee II cruciate-retaining (CR)-type prosthesis, which has 6 fins at the anterior of the femoral component, posterior cruciate ligament (PCL) retention, flat-on-flat surface component geometry, all-polyethylene patella, strong initial fixation by the center screw of the tibial base plate, 10 layers of titanium alloy fiber mesh, and direct compression molded ultra high molecular weight polyethylene (UHMWPE), is appropriate for TKA in the Japanese knee.The present study was performed to evaluate the clinical results of primary TKA in RA using the cementless Hi-Tech Knee II CR-type prosthesis. We performed 32 consecutive primary TKAs using cementless Hi-Tech Knee II CR-type prosthesis in 31 RA patients. The average follow-up period was 8 years 3 months. Clinical evaluations were performed according to the American Knee Society (KS) system, knee score, function score, radiographic evaluation, and complications. The mean postoperative maximum flexion angle was 115.6°, and the KS knee score and function score improved to 88 and 70 after surgery, respectively. Complications, such as infection, occurred in 1 patient and revision surgery was performed. There were no cases of loosening in this cohort, and prosthesis survival rate was 96.9% at 12 years postoperatively. These results suggest that TKA using the cementless Hi-Tech Knee II CR-type prosthesis is a very effective form of treatment in RA patients at 5 to 12 years postoperatively. Further long-term follow-up studies are required to determine the ultimate utility of this type of prosthesis.
Sahoo, Kulamani; Garg, Ashish; Saha, Pramod; Dodia, Jainesh Valjibhai; Raj, Vinay Rajappa; Bhairagond, Shweta Jagadish
2016-04-01
The knee is a major weight bearing joint that provides mobility and stability during physical activity as well as balance while standing. If the knee is exposed to forces beyond its physiologic range, risk of injury to bone or soft tissue structures increases. A thorough understanding of knee injury patterns and their mechanisms may help in achieving more accurate assessment of injuries. To identify imaging pattern in bone marrow oedema and to correlate the pattern of bone marrow oedema retrospectively with type of knee injury from clinical history. A cross-sectional study was done on all patients referred to Krishna Hospital, Karad for MRI knee with history of recent (< 6 weeks) knee injury. Study was conducted between May 2014 to September 2015 with a sample size of 200 patients. Plain radiograph of knee was done in all patients and they were scanned using 1.5 Tesla Seimens Avanto (Tim + Dot) with Tx/Rx 15 channel knee coil # Tim. Among the 200 cases, bone marrow contusion was noted in 138 cases (69%) and absent contusion in 62 cases (31%). Bone marrow contusion showed five patterns (according to Sanders classification) i.e., Clip injury in 39 cases (28.3%), Pivot shift injury in 78 cases (56.5%), Dashboard injury in eight cases (5.8%), Hyperextension injury in four cases (2.9%), Lateral patellar dislocation in three cases (2.2%). In six cases (4.3%) no pattern of bone marrow contusion could be explained and was categorized as unclassified pattern. Pivot shift pattern is most common contusion pattern and the most common type/mode of sports related injury. By analysing bone marrow contusion pattern, type/mode can be determined in most of the cases. By applying a biomechanical approach in MR interpretation, it is possible to detect lesions like ligament rupture and osseous contusion, to predict subtle but it might overlook important abnormalities.
Effects of hook plate on shoulder function after treatment of acromioclavicular joint dislocation.
Chen, Chang-Hong; Dong, Qi-Rong; Zhou, Rong-Kui; Zhen, Hua-Qing; Jiao, Ya-Jun
2014-01-01
Internal fixation with hook plate has been used to treat acromioclavicular joint dislocation. This study aims to evaluate the effect of its use on shoulder function, to further analyze the contributing factors, and provide a basis for selection and design of improved internal fixation treatment of the acromioclavicular joint dislocation in the future. A retrospective analysis was performed on patients treated with a hook plate for acromioclavicular joint dislocation in our hospital from January 2010 to February 2013. There were 33 cases in total, including 25 males and 8 females, with mean age of 48.27 ± 8.7 years. There were 29 cases of Rockwood type III acromioclavicular dislocation, 4 cases of type V. The Constant-Murley shoulder function scoring system was used to evaluate the shoulder function recovery status after surgery. Anteroposterior shoulder X-ray was used to assess the position of the hook plate, status of acromioclavicular joint reduction and the occurrence of postoperative complications. According to the Constant-Murley shoulder function scoring system, the average scores were 78 ± 6 points 8 to 12 months after the surgery and before the removal of the hook plate, the average scores were 89 ± 5 minutes two months after the removal of hook plate. Postoperative X-ray imaging showed osteolysis in 10 cases (30.3%), osteoarthritis in six cases (18.1%), osteolysis associated with osteoarthritis in four cases(12.1%), and steel hook broken in one case (3%). The use of hook plate on open reduction and internal fixation of the acromioclavicular joint dislocation had little adverse effect on shoulder function and is an effective method for the treatment of acromioclavicular joint dislocation. Osteoarthritis and osteolysis are the two common complications after hook plate use, which are associated with the impairment of shoulder function. Shoulder function will be improved after removal of the hook plate.
Effects of hook plate on shoulder function after treatment of acromioclavicular joint dislocation
Chen, Chang-Hong; Dong, Qi-Rong; Zhou, Rong-Kui; Zhen, Hua-Qing; Jiao, Ya-Jun
2014-01-01
Introduction: Internal fixation with hook plate has been used to treat acromioclavicular joint dislocation. This study aims to evaluate the effect of its use on shoulder function, to further analyze the contributing factors, and provide a basis for selection and design of improved internal fixation treatment of the acromioclavicular joint dislocation in the future. Methods: A retrospective analysis was performed on patients treated with a hook plate for acromioclavicular joint dislocation in our hospital from January 2010 to February 2013. There were 33 cases in total, including 25 males and 8 females, with mean age of 48.27 ± 8.7 years. There were 29 cases of Rockwood type III acromioclavicular dislocation, 4 cases of type V. The Constant-Murley shoulder function scoring system was used to evaluate the shoulder function recovery status after surgery. Anteroposterior shoulder X-ray was used to assess the position of the hook plate, status of acromioclavicular joint reduction and the occurrence of postoperative complications. Results: According to the Constant-Murley shoulder function scoring system, the average scores were 78 ± 6 points 8 to 12 months after the surgery and before the removal of the hook plate, the average scores were 89 ± 5 minutes two months after the removal of hook plate. Postoperative X-ray imaging showed osteolysis in 10 cases (30.3%), osteoarthritis in six cases (18.1%), osteolysis associated with osteoarthritis in four cases(12.1%), and steel hook broken in one case (3%). Conclusion: The use of hook plate on open reduction and internal fixation of the acromioclavicular joint dislocation had little adverse effect on shoulder function and is an effective method for the treatment of acromioclavicular joint dislocation. Osteoarthritis and osteolysis are the two common complications after hook plate use, which are associated with the impairment of shoulder function. Shoulder function will be improved after removal of the hook plate. PMID:25356110
Albrecht, E; Guyen, O; Jacot-Guillarmod, A; Kirkham, K R
2016-05-01
Many consider femoral nerve block the gold standard in pain management following knee arthroplasty. Local infiltration analgesia is an alternate approach that applies the concept of surgical wound infiltration with local anaesthetics. This meta-analysis aims to compare both analgesic treatments for analgesia and functional outcomes after total knee arthroplasty. This meta-analysis was performed according to the PRISMA statement guidelines. The primary outcomes were cumulative i.v. morphine consumption, pain scores at rest and on movement on postoperative day one (analogue scale,0-10). Secondary outcomes included range of motion, quadriceps muscle strength, length of stay and rates of complications (neurologic events, cardiovascular events, falls and knee infections). Fourteen trials, including 1122 adult patients were identified. There was no difference in i.v. morphine consumption (mean difference: -2.0 mg; 95% CI: -4.9, 0.9 mg; I(2)=69%; P=0.19), pain scores at rest (mean difference: -0.1; 95% CI: -0.4, 0.3; I(2)=72%; P=0.80) and pain scores on movement (mean difference: 0.2; 95% CI: -0.5, 0.8; I(2)=80%; P=0.64) on postoperative day one (a negative mean difference favours local infiltration analgesia). The qualities of evidence for our primary outcomes were moderate according to the GRADE system. There were no clinical differences in functional outcomes or rates of complications. Complication rates were captured by three trials or fewer with exception of knee infection, which was sought by eight trials. Local infiltration analgesia provides similar postoperative analgesia after total knee arthroplasty to femoral nerve block. Although this meta-analysis did not capture any difference in rates of complications, the low number of trials that specifically sought these outcomes dictates caution. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
[Glenohumeral instability in patients over 40 years-old: injuries, treatment and complications].
López-Hualda, A; Marín-Aguado, M A; Valencia-García, H; López-González, D; Gavín-González, C
2014-01-01
Recurrent shoulder dislocation is infrequent after forty years and presents different injuries than younger patients. To compare injuries and complications after surgery between one group older than forty years of age and another younger group. A review was made o all patients who had undergone arthroscopic surgery due to glenohumeral instability from 1999 until 2011. The mean follow-up was 64 months. The case group consisted of all patients older than 40 years at the time of the surgery (n=21), which was compared with a similar sized control group of randomly selected younger patients (n=27). The mean age in the older group was 54 years (SD 11.86), while it was 26 years (SD 5.80) in the younger group. No differences were founded between both groups in labrum injury, Hill-Sachs injury, and bone Bankart lesion (P>.05). Rotator cuff tears were 7.3 times (95% CI; 2.5-21.6) more frequent in the older group (81%) compared to the younger group (P<.05). However, neurological injuries after dislocation were not more frequent in this group. There was no significant difference between the complications after surgery and the age according to the design (P>.05). Anterior recurrent dislocation after forty years of age is usually associated with rotator cuff tears. Arthroscopic treatment of instability was effective with no more postoperative complications. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.
Wohlrath, B; Schweigkofler, U; Barzen, S; Heinz, S M; Schmidt-Horlohé, K; Hoffmann, R
2016-12-01
Background: Protracted dislocation of the upper ankle joint can lead to substantial damage to the surrounding soft tissue, possibly followed by local complications and longer hospitalisation. Although reposition is usually easy to conduct, it is commonly recommended that this should only be performed by an experienced specialist, as long as there is no neurovascular restriction. There are however no exact data or studies on this problem. The aim of the present study is to examine whether early reposition is of benefit for subsequent treatment. Methods: Retrospective study of all patients in a supra-regional trauma centre during the period from January 2009 to July 2015, with either prehospital reposition of the ankle joint because of visible malposition or documented visible malposition on arrival at hospital. Patients with relevant concomitant injuries elsewhere were excluded. Data on the duration of dislocation were matched with diagnostic findings at the time of hospital admission, the kind of primary care, local complications and the time of hospitalisation, using linear regression analysis and ANOVA calculations. Results: Of a total of 391 patients with a dislocation or a fracture dislocation of the ankle joint within this period, 132 fulfilled the inclusion criteria. These patients were divided into 5 groups on the basis of the time of dislocation. Time to reposition was less than one hour for 39 patients, between one and two hours for 29 patients, between two and six hours for 41 patients, between six and 24 hours for 13 patients and more than 24 hours for 10 patients, all with a visible dislocation. The results on admission showed a significant increase in skin bruises and tension bullae with increasing time of dislocation. A longer time of dislocation was associated with more two stage surgical procedures with external fixators and a decreasing number of single stage procedures. While there was immediate definitive treatment of 79.5 % of the patients in the first group, this figure decreased continuously to 10.0 % in the last group. The number of local complications increased significantly in every group with the duration of dislocation. In particular, the incidence of severe swelling, wound healing disorders, skin necrosis and the need for revision surgery and plastic reconstruction exhibit a significant linear increase within the groups (p < 0.05). The incidence of severe swelling rose from 10.3 % in the first group, to 31.0 % in the second group, to 100 % in the last group. The incidence of wound healing disorders rose from 7.7 to 13.8 to 80 % and the incidence of skin necrosis from 2.6 to 3.5 to 30.0 %. The duration of hospitalisation also exhibited a significant linear increase with group affiliation (p < 0.001), from 8.3 days in the first group to 12.5 days in the second group and 30.5 days in the last group. Conclusion: This study shows the importance of conducting reposition of the ankle joint as soon as possible if there is visible malposition, in order to avoid local complications and longer hospitalisation. If there is visible malposition of the ankle joint, the best procedure is immediate - ideally prehospital - reposition and in-axis splinting, in order to preserve soft tissue. Georg Thieme Verlag KG Stuttgart · New York.
Knee arthrodesis with the Wichita Fusion Nail: an outcome comparison.
McQueen, D A; Cooke, F W; Hahn, D L
2006-05-01
The Wichita Fusion Nail (WFN) is a knee arthrodesis stabilization system that employs compression via an intramedullary rod. It was designed for use in the salvage of the irretrievably failed total knee arthroplasty and other severe knee pathologies. Questionnaires covering the fusion success rate, fusion time, and complication rate were obtained from 33 surgeons who were among the first to use the device. Data from these questionnaires were analyzed to determine if the rate of successful fusion was close to 100%, which was the primary hypothesis of this study. The average time required to achieve fusion and the rate of complications were also calculated and compared to similar results available in the literature. The results for 44 selected patients were included and it was determined that all achieved fusion for a success rate of 100%. This compared favorably with reported success rates in the range of 54% to 96%. The average fusion time was 15.5 weeks. Complications included: six delayed unions, three deep infections, and two periimplant fractures for a major complications rate of 20.4%. Both the fusion times and complication rate compared favorably with other reported results. Surgeons using the device for the first time had outcomes equal to those of more experienced users. Our results demonstrated that a rate of successful arthrodesis close to 100% could be consistently achieved with the WFN. Overall, the WFN facilitated an improved outcome for a previously difficult procedure. Therapeutic study, level IV (case series). See the Guidelines for Authors for a complete description of level of evidence.
Choi, Soohwan; Park, Hyung Joo
2017-10-01
To compare the complications associated with age and technique groups in patients undergoing pectus excavatum (PE) repair. The data of 994 patients who underwent PE repair from March 2011 to December 2015 were retrospectively reviewed. Mean age was 9.59 years (range 31 months-55 years), and 756 patients were men (76.1%). The age groups were defined as follows: Group 1, <5 years; Group 2, 5-9 years; Group 3, 10-14 years; Group 4, 15-17 years; Group 5, 18-19 years; Group 6, 20-24 years; and Group 7, >24 years. The technique groups were defined as follows: Group 1, patients who underwent repair with claw fixators and hinge plates; Group 2, patients who underwent repair with our 'bridge' technique. Complications were compared between age groups and technique groups. No cases of mortality occurred. Complication rates in the age groups 1-7 were 5.4%, 3.6%, 12.1%, 18.2%, 17.3%, 13.9% and 16.7%, respectively. The complication rate tripled after the age of 10. In multivariable analysis, odds ratio of Groups 4, 5 and 7 and asymmetric types were 3.04, 2.81, 2.97 and 1.70 (P < 0.01, P = 0.02, 0.03 and 0.03, respectively). The bar dislocation rate in technique Group 1 was 0.8% (6 of 780). No bar dislocations occurred in technique Group 2. Older patients have more asymmetric pectus deformity and they are also risk factors for complications following PE repair. The bridge technique provides a bar dislocation rate of 0%, even in adult patients. This procedure seems to reduce or prevent major complications following PE repair. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
de Thomasson, E; Guingand, O; Terracher, R; Mazel, C
2001-09-01
We conducted a retrospective study to assess morbidity and mortality in patients undergoing revision total hip arthroplasty (THA) procedures. Perioperative complications were recorded in 181 revision procedures (162 patients) performed between January 1995 and March 1999 (117 bipolar revisions and 64 acetabular isolated revisions). There were 86 complications (68 patients) leading to 21 new revisions. About half (50/86) were related to the surgical procedure (dislocation, femoral fracture, infection.). Life-threatening complications (3.6%) ended in patient death in 1.6% of the cases. Complications were more frequent in patients with an ASA score=3 (p<0.01) or aged over 75 years (p<0.05). Age was also predictive of femoral misalignment and fracture (p<0.05). Dislocations (8.8%) were observed more frequently in patients who had undergone more than 2 procedures prior to the revision (p<0.05) (4.8% of the dislocations in patients undergoing a first revision procedure and 14.3% in the others). In addition, peroperative blood loss and duration of the procedure were significantly greater in case of bipolar replacement than for isolated acetabular replacement (sigma > 1.96). Our experience and data in the literature point to the important age factor in the development of complications. Preservation of a well-fixed femoral component does not appear to worsen prognosis and leads to fewer complications than bipolar changes. The decision to revise a THA must take into consideration the functional impairment but also the risks inherent in revision procedures, particularly in old patients who have undergone several procedures. Revising the acetabular component alone can be an interesting option if the femoral component remains well-fixed although our follow-up is insufficient to determine whether this attitude provides better long-term outcome than complete biopolar revision. Better patient selection and improved operative technique, in particular in femur preparation, should help reduce morbidity and mortality in this type of procedure.
Complication Rates for Hip Arthroscopy Are Underestimated: A Population-Based Study.
Truntzer, Jeremy N; Hoppe, Daniel J; Shapiro, Lauren M; Abrams, Geoffrey D; Safran, Marc
2017-06-01
To identify major and minor complication rates associated with hip arthroscopy from a payer-based national database and compare with the rates reported in the existing literature. Patients who underwent hip arthroscopy between 2007 and 2014 were identified using PearlDiver, a publicly available database. Rates of major and minor complications, as well as conversion to total hip arthroscopy (THA), were determined by using Current Procedural Terminology (CPT) and International Classification of Diseases, Ninth Revision (ICD-9), codes. Incidence rates of select major complications across the entire database were used as a comparison group. Statistical significance was set at P < .05. Of 18 million patients screened from 2007 to 2014, a total of 2,581 hip arthroscopies were identified. The rates of major and minor complications within a 1-year postoperative period were 1.74% and 4.22%, respectively. Complications included heterotopic ossification (2.85%), bursitis (1.23%), proximal femur fracture (1.08%), deep vein thrombosis (0.79%), and hip dislocation (0.58%). The rate of conversion to THA within 1 year was 2.85%. When compared to rates in the general population, the relative risks [RRs] of requiring a THA (age <50 years, RR = 57.66, P < .001; age >50 years, RR = 22.05, P < .001), sustaining a proximal femur fracture (age <50 years, RR = 18.02, P < .001; age >50 years, RR = 2.23, P < .001), or experiencing a hip dislocation (RR 19.60, P < .001) at 1 year after hip arthroscopy were significantly higher in all age groups. Higher major complication rates after hip arthroscopy were observed using a national payer-based database than previously reported in the literature, especially in regard to hip dislocations and proximal femur fractures. Rates of total hip arthroplasty were similar to prior studies, whereas the rates of revision hip arthroscopy were higher. Level IV, case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Martins, Wilson Denis; Ribas, Marina de Oliveira; Bisinelli, Julio; França, Beatriz Helena S; Martins, Guilherme
2014-04-01
Dislocation of the temporomandibular joint (TMJ) is a troublesome condition that occurs in a chronic or acute form. It is a distressing and highly embarrassing situation that may occur as a result of daily activities such as yawning, laughing, or during events that require keeping the mouth open for a long time. This review aims to present and discuss different conservative and surgical techniques to treat patients with a dislocated mandible, and to present two cases of surgical treatment. A search of the literature was completed (Medline, PubMed) using the keywords TMJ dislocation, TMJ luxation, mandibular dislocation and surgical and non-surgical methods of treatment for this condition. Eminectomy (Myrhaug's surgery) has been used with satisfactory results. Most of reports present large series of patients with more than one year of follow-up and no recurrence of complications. Is less invasive and take a short operation time; need no bone transplantation or placing any kind of foreign body into the joint. Eminectomy results in long-term resolution of recurrent TMJ dislocations, when compared with others surgical techniques.
Mehlhorn, Alexander T; Walther, Markus; Iblher, Niklas; Südkamp, Norbert P; Schmal, Hagen
2016-12-01
In Charcot's osteoarthropathy stabilization of the medial column of the foot was introduced in order to establish a stable foot and reduce the risk for amputation. This study was performed to analyze postoperative complications, define risk factors for those and develop strategies for prevention. Since bolt dislocation takes place frequently, it was aimed to predict an appropriate time point for bolt removal under the condition that osseous healing has occurred. Fourteen consecutive patients with neuroosteoarthropathy of the foot and arch collapse were treated with open reduction and stabilization using midfoot fusion bolt and lateral lag screws. Age, gender, presence of preoperative osteomyelitis or ulcer, number of complications and operative revisions, Hba1c value, consolidation of arthrodesis, presence of a load-bearing foot and period to bolt dislocation was assessed. The mean follow-up was 21.4±14.6 (mean±SDM) months, 64% of patients suffered from diabetes with a preoperative Hba1c of 8.5±2.4. The mean number of revisions per foot was 3.6±4.1. Bolt dislocation was seen in 57% of the patients following 11.3±8.5 months; in 75% of these patients bony healing occurred before dislocation. There was a significant association between preoperative increased Hba1c value, presence of preoperative ulcer and wound infection. Healing of arthrodesis was demonstrated in 57% and a permanent weight-bearing foot without recurrent ulcer was achieved in 79%. The early and late postoperative complications could be controlled in general. A fully load-bearing and stable foot was obtained, despite osseous consolidation was not detected in all of these cases. Once a stable foot has established early removal of fusion bolt should be considered. To decrease the risk of infection Hba1c should be adjusted and ulcers should be treated before the operation. Copyright © 2016 Elsevier Ltd. All rights reserved.
[Outcomes and complications of Tightrope button plate for repairing acromioclavicular dislocation].
Zuo, Yong-Xiang; Ma, Zi-Ping
2017-10-25
To study the clinical outcome and complications of Tightrope button plate for repairing acromioclavicular dislocation of Rockwood type III to V. From May 2014 to December 2016, 17 patients with acromioclavicular dislocation of type III-V were treated with Tightrope button plate including 10 males and 7 females with an average age 39.8 years old ranging from 20 to 68 years old. Four patients were treated with arthroscopy and 17 patients were treated with mini-invasive by X-ray assisted. Shoulder function, X-ray and complications after operation were assessed. All patients were followed up for 5 to 23 months with a mean of 10.8 months. All patients got satisfying reduction immediately postoperatively. Among them, 1 case of clavicle end wound foreign body reaction, rupture, effusion, healing after the second suture; 1 case of foreign body granuloma formation at the end of clavicle were resected and removed at 4 months after operation; 3 cases loss reduction(less than 50% of acromioclavicular joint). No coracoid fracture and suture breakage observed. The shoulder mobility was restored in 15 cases at 4 to 6 weeks postoperatively, and the shoulder adhesion in 2 cases was delayed to 5 to 7 months after operation. The Constant scores were improved from 46.9±6.0 preoperatively to 92.7±4.0 at the final follow-up. X-ray evaluation of postoperative coracoclavicular tunnel location, patients' coracoclavicular tunnel with mini-invasive fluoroscopy all closed to the ideal position (across the clavicle vertically through the coracoid base center), while different degree of tunnel position deviation were observed in arthroscopic patients. Tightrope button plate for the treatment of acromioclavicular joint dislocation had advantages of minimally invasive, effective, good clinical results, the majority of common complications does not affect efficacy. Small incision X-ray method can provide more satisfactory and reliable tunnel location.
Late extensor pollicis longus rupture following plate fixation in Galeazzi fracture dislocation
Sabat, Dhananjaya; Dabas, Vineet; Dhal, Anil
2014-01-01
Late rupture of extensor pollicis longus (EPL) tendon after Galeazzi fracture dislocation fixation is an unknown entity though it is a well-established complication following distal radius fractures. We report the case of a 55-year old male who presented with late EPL tendon rupture 4 months following internal fixation of Galeazzi fracture dislocation with a Locking Compression Plate (LCP). He was managed with extensor indicis proprius (EIP) transfer to restore thumb extension. At 4 years followup, functional result of the transfer was good. We identify possible pitfalls with this particular patient and discuss how to avoid them in future. PMID:25143650
Could larger diameter of 4th generation ceramic bearing decrease the rate of dislocation after THA?
Lee, Young-Kyun; Ha, Yong-Chan; Jo, Woo-Lam; Kim, Tae-Young; Jung, Woon-Hwa; Koo, Kyung-Hoi
2016-05-01
Fourth generation (Delta) ceramic bearing was developed to reduce dislocation after total hip arthroplasty (THA) by increasing the head diameter. We tested a hypothesis that 32/36 mm Delta ceramic bearing decreases the dislocation rate. We also evaluated ceramic-related complications and early outcome of this thin liner-on-large head ceramic bearing. We performed a prospective study on patients who underwent THA with use of 32/36 mm Delta ceramic bearing. The dislocation rate was compared with the historical dislocation rate of third generation 28 mm ceramic bearing. We also evaluated ceramic fracture, squeak, short-term results and survival. Follow-up period was minimum 2 years. Between April 2010 and February 2012, we enrolled 250 consecutive patients (278 hips). All patients received cementless prostheses. Four patients (4 hips) who received metal shells ≤ 46 mm and 28 mm heads were excluded. Three patients died and 2 patients were lost within 2 years. The remaining 241 patients (269 hips) were followed for 24-46 months. There were 142 men (161 hips) and 99 women (108 hips) with a mean age of 53.7 years (range, 17-75 years) at the index operation. Dislocation occurred in three hips (1.1%). An old age was a risk factor for dislocation. Ceramic fracture and squeaking did not occur in any patient. Mean Harris hip score was 90.3 points at the latest follow-up. All acetabular and femoral components had bone-ingrowth stability. No hip had detectable wear or osteolysis. The survival was 99.3% in the best case scenario and 97.8% in the worst at 48 months. Total hip arthroplasty with use of 32/36 mm Delta ceramic bearing showed lower incidence of hip dislocation compared with 28 mm third generation ceramic bearing. A caution should be paid to prevent a fall in senile patients even though a large head is used. The short-term results of THA with this type of ceramic articulation are encouraging and we did not find any ceramic-related complications. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
von Engelhardt, Lars V; Weskamp, Pia; Lahner, Matthias; Spahn, Gunter; Jerosch, Joerg
2017-01-01
AIM To evaluate our modified deepening trochleoplasty combined with a balanced medial patellofemoral ligament (MPFL) reconstruction for soft tissue alignement. METHODS Thirty-three knees with with recurrent patellar dislocations and a trochlear dysplasia in 30 patients (m/f = 12/21, mean age 24 ± 9 years) underwent a combination of a modified deepening trochleoplasty and a balanced MPFL reconstruction for a medial soft tissue alignement. After a mean follow-up period of 29 ± 23 mo, patients’ return to sports, possible complications as well as the clinical outcomes using the Kujala, International Knee Documentation Committee (IKDC) and Lysholm scoring were evaluated. Moreover, patients’ satisfaction with the general outcome, the cosmetic outcome, the pre- and postoperative pain and a potential avoidance behaviour were assessed with additional standardized questionnaires which also included different visual analog scales. RESULTS There were no signs of a persistent instability. The Kujala score improved from a mean of 64 ± 16 points to 94 ± 9 points, the Lysholm score improved from a mean of 63 ± 17 to 95 ± 6 points and the IKDC score from 58 ± 11 to 85 ± 12 points, P < 0.0001, respectively. The assessment of pain using a visual analog scale showed a significant pain reduction from a mean of 4.8 ± 2.0 to 1.3 ± 3.4 points (P < 0.0001). Two of 26 cases (92%) who were engaged in regular physical activity before surgery did not return to full sporting activities. One patient felt that his sport was too risky for his knee and reported an ongoing avoidance behaviour. The other patient preferred to wait for surgery of her contralateral knee. Of the eight patients who were not engaged in sporting activities before surgery, three started regular sporting activities after surgery. In 31 of the 33 cases (94%), the patients were very satisfied with the clinical outcome of the surgery. Regarding the cosmetic results, no patients felt impaired in their self-confidence and in their clothing decisions. CONCLUSION Our technique shows a good clinical outcome in terms of the common scorings as well as in terms of pain, return to sports and patient satisfaction. PMID:29312853
2013-01-01
Background Pseudoaneurysm of superior lateral genicular artery following total knee arthroplasty is a rare complication and has been reported following lateral release performed for eversion of patella in a knee with tight lateral structures. Case presentation This report describes a case of pseudo aneurysm of superior lateral geniculate artery that developed after primary Total knee arthroplasty for a stiff knee in a 68 year old patient. Patient presented with pain and rapidly increasing swelling in early post operative period. Diagnosis was made on duplex ultrasound and confirmed by angiography. Angiographic coil embolisation of the pseudoaneurysm was performed. Since no lateral release was performed in this case, the probable mechanism was shear injury to the vessel. Conclusion Pseudoaneurysm of superior lateral genicular artery can occur in absence of lateral release by shear injury to an atherosclerotic vessel. Angiographic coil embolisation appears to be the best method for treating such post arthroplasty pseudoaneurysm because of less chance of infection, non interference with rehabilitation and diagnosis and treatment during same procedure. PMID:23687974
Early results of patellofemoral inlay resurfacing arthroplasty using the HemiCap Wave prosthesis.
Patel, Akash; Haider, Zakir; Anand, Amarjit; Spicer, Dominic
2017-01-01
Common surgical treatment options for isolated patellofemoral osteoarthritis include arthroscopic procedures, total knee replacement and patellofemoral replacement. The HemiCap Wave patellofemoral resurfacing prosthesis is a novel inlay design introduced in 2009 with scarce published data on its functional outcomes. We aim to prospectively evaluate early functional outcomes and complications, for patients undergoing a novel inlay resurfacing arthroplasty for isolated patellofemoral arthrosis in an independent centre. From 2010 to 2013, 16 consecutive patients underwent patellofemoral resurfacing procedures using HemiCap Wave (Arthrosurface Inc., Franklin, Massachusetts, USA) for anterior knee pain with confirmed radiologically and/or arthroscopically isolated severe patellofemoral arthrosis. Standardized surgical technique, as recommended by the implant manufacturer, was followed. Outcome measures included range of movement, functional knee scores (Oxford Knee Score (OKS), Knee Injury and Osteoarthritis Outcome Score (KOOS) and Short Form-36 (SF-36)), radiographic disease progression, revision rates and complications. Eight men and eight women underwent patellofemoral HemiCap Wave resurfacing, with an average age of 63 years (range: 46-83). Average follow-up was 24.1 months (6-34). Overall, post-operative scores were excellent. There was a statistically significant improvement in the post-operative OKS, KOOS and SF-36 scores ( p < 0.01). One patient had radiological disease progression. One patient underwent revision for deep infection. Two other minor complications were observed and treated conservatively. The HemiCap Wave patellofemoral resurfacing prosthesis has excellent early results in terms of functional outcomes, radiological outcomes and low complication rates. At the very least, early results show that the HemiCap Wave is comparable to more established onlay prostheses. The HemiCap Wave thus provides a safe and effective surgical option in the treatment of isolated patellofemoral osteoarthritis in selected patients.
Acetabular cup position and risk of dislocation in primary total hip arthroplasty.
Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik; Husted, Henrik; Gromov, Kirill
2017-02-01
Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation - The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies.
Acetabular cup position and risk of dislocation in primary total hip arthroplasty
Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik; Husted, Henrik; Gromov, Kirill
2017-01-01
Background and purpose — Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods — A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results— 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation— The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies. PMID:27879150
Total knee replacement with tibial tubercle osteotomy in rheumatoid patients with stiff knee.
Eid, Ahmed Salem; Nassar, Wael Ahmed Mohamed; Fayyad, Tamer Abdelmeguid Mohamed
2016-11-01
Total knee arthroplasty (TKA) is a well-proven modality that can provide pain relief and restore mobility for rheumatoid arthritis (RA) patients with advanced joint destruction. Patellar ligament avulsion, especially in presence of poor bone quality and knee stiffness, is one of the special considerations that must be addressed in this unique population of patients. This study aimed to determine the functional results in a series of rheumatoid patients with stiff knee and end-stage joint destruction who underwent tibial tubercle osteotomy during TKA. Twenty-three knees in 20 patients (16 women; four men) at a mean age of 54 years with end-stage arthritis and knee stiffness due to RA were operated upon for TKA using tibial tubercle osteotomy as a step during the operation. Patients were reviewed clinically and radiographically with a minimum follow-up of two years. Complications were noted. Hospital for Special Surgery (HSS) score was recorded pre-operatively and at six and 12 months postoperatively. Union occurred at the osteotomy site in 21 of 23 cases. One case had deep venous thrombosis (DVT). There was no infection or periprosthetic fracture, and at last follow-up, no patient required revision. HSS score improved from 46 (15-60) pre-operatively to 85 (71-96) post-operatively. Tibial tubercle osteotomy during TKA in patients with RA and stiff knee is technically demanding yet proved to be effective in improving post-operative range of movement and minimising the complication of patellar ligament avulsion.
Bouchet, R; Mercier, N; Saragaglia, D
2011-02-01
Dislocation is a frequent complication of total hip arthroplasties (THA) especially in older patients, especially when using a posterior approach. In these cases, dual mobility (DM) cups developed by Gilles Bousquet in 1975 can be indicated to reduce this complication risk. Dual mobility cups reduce the rate of dislocation in primary total hip arthroplasty using posterior approach in a single-surgeon series. Test this hypothesis in a controlled study to compare the rate of dislocation in primary total hip arthroplasties done in patients over 50 years old either with a dual mobility cup or a conventional metal-on-polyethylene 28-mm diameter head. Two consecutive series of primary total hip replacements were performed by a single surgeon using a posterolateral approach. The piriformis tendon was left intact. The DM series included 105 patients who underwent arthroplasty between January 2005 and June 2007 with a dual mobility cup (60 women and 45 men, mean age 76.6±5.65 years old [53-93]). The control series (S series) included 108 patients who underwent arthroplasty (56 women and 52 men, mean age 74.2±5.9 years old [53-87]) with a conventional 28-mm polyethylene cup between January 2003 and June 2005. All hip replacements included a 28-mm metal-polyethylene cup and a 12-14-mm Morse taper. Both groups were comparable for gender, diagnosis, body mass index, type of anesthesia and ASA score distribution. All patients included in this series had a minimum follow-up of 1 year. There were no dislocations in the DM series and five early dislocations (before the third month) in the S series for a rate of 4.63%. Although the rate of dislocation was higher in the S series (4.63% vs 0%), the difference was barely significant (P=0.0597). This study comparing the incidence of dislocations after THA with conventional or dual mobility cups, shows that even using a posterior approach and in older patients, dual mobility cups increase stability with no postoperative dislocations. Although results are barely significant, a larger series should confirm the benefit of this implant. In this series, morbidity was not increased with dual mobility cups. Level III: retrospective case-control study. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Ferrel, Jason R; Davis, Richard L; Agha, Obiajulu A J C; Politi, Joel R
2015-05-01
Poor range of motion may decrease a patient's ability to participate in activities of daily living after total knee arthroplasty. Manipulation under anesthesia has been shown to improve range of motion; however, some patients have persistent stiffness even after manipulation. The goal of this study was to evaluate the outcomes and complications of patients who underwent a second manipulation under anesthesia for persistent stiffness after total knee arthroplasty. The review of surgical records of two joint arthroplasty surgeons identified 226 knees in 210 patients who underwent a manipulation under anesthesia for poor range of motion after total knee arthroplasty. Of these patients, 16 patients underwent a second manipulation under anesthesia. For patients undergoing two manipulations under anesthesia procedures, at latest follow up (mean 539 days), mean extension improved from 10.50° to 2.50° (p=0.001) and mean flexion improved from 87.50° to 112.69° (p=0.001) respectively. SF-12 scores were available for 12 of 16 knees with a mean score of 34.42. Two of 16 patients (12.5%) experienced a complication. Three of 16 (18.8%) patients who underwent a second manipulation required a revision arthroplasty procedure. In conclusion, a second manipulation under anesthesia can achieve functional range of motion that is sustained after total knee arthroplasty.
MR Imaging of Knee Arthroplasty Implants
Fritz, Jan; Lurie, Brett
2015-01-01
Primary total knee arthroplasty is a highly effective treatment that relieves pain and improves joint function in a large percentage of patients. Despite an initially satisfactory surgical outcome, pain, dysfunction, and implant failure can occur over time. Identifying the etiology of complications is vital for appropriate management and proper timing of revision. Due to the increasing number of knee arthroplasties performed and decreasing patient age at implantation, there is a demand for accurate diagnosis to determine appropriate treatment of symptomatic joints following knee arthroplasty, and for monitoring of patients at risk. Magnetic resonance (MR) imaging allows for comprehensive imaging evaluation of the tissues surrounding knee arthroplasty implants with metallic components, including the polyethylene components. Optimized conventional and advanced pulse sequences can result in substantial metallic artifact reduction and afford improved visualization of bone, implant-tissue interfaces, and periprosthetic soft tissue for the diagnosis of arthroplasty-related complications. In this review article, we discuss strategies for MR imaging around knee arthroplasty implants and illustrate the imaging appearances of common modes of failure, including aseptic loosening, polyethylene wear–induced synovitis and osteolysis, periprosthetic joint infections, fracture, patellar clunk syndrome, recurrent hemarthrosis, arthrofibrosis, component malalignment, extensor mechanism injury, and instability. A systematic approach is provided for evaluation of MR imaging of knee implants. MR imaging with optimized conventional pulse sequences and advanced metal artifact reduction techniques can contribute important information for diagnosis, prognosis, risk stratification, and surgical planning. ©RSNA, 2015 PMID:26295591
[Trigeminal motor paralysis and dislocation of the temporo-mandibular joints].
Ohkawa, S; Yoshida, T; Ohsumi, Y; Tabuchi, M
1996-07-01
A 64-year-old woman with diabetes mellitus was admitted to our hospital with left hemiparesis of sudden onset. A brain MRI demonstrated a cerebral infarction in the ventral part of the right lower pons. When left hemiparesis worsened, she had dislocation of the temporo-mandibular joints repeatedly. Then, her lower jaw deviated to the right when she opened her mouth. Also, there was decreased contraction of the right masseter when she clenched her teeth. These findings suggest that there was trigeminal motor paralysis on the right side resulting from involvement of the intrapontine trigeminal motor nerve. She has no history of dislocation of the temporo-mandibular joints. An X-ray film showed that the temporo-mandibular joints were intact. Thus, it is possible that deviation of the lower jaw was the cause of this dislocation. We suspect that dislocation of the temporo-mandibular joints may occur as a complication of unilateral trigeminal motor paralysis. This has not been reported to our knowledge.
A rare case of traumatic subretinal migration of crystalline lens, corroborated histologically.
Bawankar, Pritam; Das, Dipankar; Agarwal, Balmukund; Bhattacharjee, Kasturi; Tayab, Shahinur; Deka, Panna; Singh, Anshul; Borah, Erani; Dhar, Shriya
2017-12-01
Blunt trauma is the most common cause of posterior dislocation of the crystalline lens. We describe a rare case of subretinal migration of crystalline lens through the giant retinal tear following blunt ocular trauma. This incidental finding of subretinal dislocation of lens following blunt ocular trauma was confirmed on histopathological examination of the enucleated eye. This complication has not been described by histopathological examination in literature so far.
A rare case of traumatic subretinal migration of crystalline lens, corroborated histologically
Bawankar, Pritam; Das, Dipankar; Agarwal, Balmukund; Bhattacharjee, Kasturi; Tayab, Shahinur; Deka, Panna; Singh, Anshul; Borah, Erani; Dhar, Shriya
2017-01-01
Blunt trauma is the most common cause of posterior dislocation of the crystalline lens. We describe a rare case of subretinal migration of crystalline lens through the giant retinal tear following blunt ocular trauma. This incidental finding of subretinal dislocation of lens following blunt ocular trauma was confirmed on histopathological examination of the enucleated eye. This complication has not been described by histopathological examination in literature so far. PMID:29208844
Secondary infection of haematoma following closed acromioclavicular joint dislocation
Dupley, Leanne; Berg, Andrew James; Mohil, Randeep
2016-01-01
An unusual case of a patient presenting with a large infected haematoma following a traumatic grade II acromioclavicular joint dislocation is reported. Diagnosis of this rare complication, of an otherwise common self-limiting injury, was delayed until 19 days postinjury despite several presentations during this time with worsening swelling and pain. The patient was found to have significant tissue destruction by the time washout was performed and required multiple procedures to treat the infection. This case highlights the need for a high index of suspicion for complications, even following common self-limiting injuries, when patients represent with symptoms that do not fit the usual natural history of the condition, particularly if they have risk factors for bleeding and infection. PMID:26786526
Peters, Christopher L; Jimenez, Chris; Erickson, Jill; Anderson, Mike B; Pelt, Christopher E
2013-10-16
Soft-tissue releases are commonly necessary to achieve symmetrical flexion and extension gaps in primary total knee arthroplasty performed with a measured resection technique. We reviewed the frequency of required releases according to preoperative alignment and the clinical and radiographic results; associations with failure, reoperations, and complications are presented. We reviewed 1216 knees that underwent primary total knee arthroplasty from 2004 to 2009; 774 (64%) were in female patients and 442 (36%), in male patients. In the coronal plane, 855 knees had preoperative varus deformity, 123 were neutral, and 238 had valgus deformity. The mean age at the time of the index procedure was 62.7 years (range, twenty-three to ninety-four years), and the mean body mass index was 32.7 kg/m² (range, 17.4 to 87.9 kg/m²). Clinical outcomes included the Knee Society Score (KSS), implant failure, reoperation, and complications. Radiographs were analyzed for component alignment. The only difference in the total KSS was found at the time of final follow-up between valgus knees with zero releases (total KSS = 178) and those with one or two releases (KSS = 160, p = 0.026). Overall, 407 knees (33.5%) required zero releases, 686 (56.4%) required one or two releases, and 123 (10.1%) required three or more releases. Among varus knees, 37% required zero releases, 55% required one or two releases, and 7.5% required three or more releases. Among neutral knees, 39% required zero releases, 55% required one or two releases, and 5.7% required three or more releases. Only 17% of valgus knees required zero releases whereas 61% required one or two releases and 21.8% required three or more releases. Valgus knees required more releases than neutral or varus knees did (p < 0.001). Selective soft-tissue release for gap balancing in primary total knee arthroplasty is an effective technique that produced excellent clinical and radiographic results regardless of preoperative alignment. Consistent anatomic coronal-plane alignment and soft-tissue balance could be achieved without bone cut modification by using measured bone resection and selective soft-tissue release.
Gautam, Arvind; Callejas, Miguel A; Acharyya, Amit; Acharyya, Swati Ghosh
2018-05-01
This study introduced a shape memory alloy (SMA)-based smart knee spacer for total knee arthroplasty (TKA). Subsequently, a 3D CAD model of a smart tibial component of TKA was designed in Solidworks software, and verified using a finite element analysis in ANSYS Workbench. The two major properties of the SMA (NiTi), the pseudoelasticity (PE) and shape memory effect (SME), were exploited, modelled, and analysed for a TKA application. The effectiveness of the proposed model was verified in ANSYS Workbench through the finite element analysis (FEA) of the maximum deformation and equivalent (von Mises) stress distribution. The proposed model was also compared with a polymethylmethacrylate (PMMA)-based spacer for the upper portion of the tibial component for three subjects with body mass index (BMI) of 23.88, 31.09, and 38.39. The proposed SMA -based smart knee spacer contained 96.66978% less deformation with a standard deviation of 0.01738 than that of the corresponding PMMA based counterpart for the same load and flexion angle. Based on the maximum deformation analysis, the PMMA-based spacer had 30 times more permanent deformation than that of the proposed SMA-based spacer for the same load and flexion angle. The SME property of the lower portion of the tibial component for fixation of the spacer at its position was verified by an FEA in ANSYS. Wherein, a strain life-based fatigue analysis was performed and tested for the PE and SME built spacers through the FEA. Therefore, the SMA-based smart knee spacer eliminated the drawbacks of the PMMA-based spacer, including spacer fracture, loosening, dislocation, tilting or translation, and knee subluxation. Copyright © 2018. Published by Elsevier Ltd.
Tang, Hongwei; Gao, Sheng; Yin, Yong; Li, Yunfei; Han, Qingtian; Li, Huizhang
2015-11-01
To evaluate and compare the effectiveness of double Endobutton technique and suture anchor combined Endobutton plate in the treatment of Tossy type III acromioclavicular joint dislocation. Between May 2010 and March 2014, a retrospective study was preformed on 56 patients with Tossy type III acromioclavicular joint dislocation. The coracoclavicular ligament was reconstructed with double Endobutton technique in 31 cases (Endobutton group), and with suture anchor combined Endobutton plate in 25 cases (Anchor group). There was no significant difference in age, gender, injury causes, injury side, associated injury, medical comorbidities, and disease duration between 2 groups (P>0.05). The operation time, medical device expenses, postoperative complications, preoperative and postoperative Constant-Murley scores, and postoperative Karlsson grading of the injured shoulder were compared between 2 groups. The average operation time in Endobutton group was significantly greater than that in Anchor group (t = 4.285, P = 0.000); there was no significant difference in the medical device expenses between 2 groups (t = 1.555, P = 0.126). Primary healing of incision was obtained in all patients of 2 groups; no early complications of infection and skin necrosis occurred. All patients were followed up 15.6 months on average (range, 11-35 months). During follow-up, some loss of reduction and ectopic ossification in the coracoclavicular gap were observed in 1 case and 6 cases of Endobutton group, respectively. No recurrence of acromioclavicular joint dislocation, implant fixation loosening and broken, and secondary fractures occurred in the other patients. There was significant difference in the incidence of postoperative complications between 2 groups (P = 0.013). Constant-Murley scores of the injured shoulder significantly increased at 9 months after operation when compared with preoperative values in 2 groups (P < 0.05), but no significant difference was observed between 2 groups (P > 0.05). At last follow-up, there was no significant difference in Karlsson grading between 2 groups (Z = -0.628, P = 0.530). Both double Endobutton technique and suture anchor combined Endobutton plate have good effectiveness in the treatment of Tossy type III acromioclavicular joint dislocation. But the latter is associated with easier operation, less operation time, and less complications.
Periprosthetic fractures of the femur after total knee arthroplasty.
McGraw, Phil; Kumar, Arun
2010-09-01
Periprosthetic fracture following total knee arthroplasty is a potentially serious complication. This injury can involve the distal femur, proximal tibia or the patella. This review article analyzes the prevalence, risk factors, classification and treatment options for periprosthetic fractures of the femur.
Mechanism and energetics of
NASA Astrophysics Data System (ADS)
Wu, Zhaoxuan; Curtin, W. A.
2016-10-01
Hexagonal close-packed (hcp) metals such as Mg, Ti, and Zr are lightweight and/or durable metals with critical structural applications in the automotive (Mg), aerospace (Ti), and nuclear (Zr) industries. The hcp structure, however, brings significant complications in the mechanisms of plastic deformation, strengthening, and ductility, and these complications pose significant challenges in advancing the science and engineering of these metals. In hcp metals, generalized plasticity requires the activation of slip on pyramidal planes, but the structure, motion, and cross-slip of the associated
The feasibility and perioperative complications of outpatient knee arthroplasty.
Berger, Richard A; Kusuma, Sharat K; Sanders, Sheila A; Thill, Elizabeth S; Sporer, Scott M
2009-06-01
The duration of hospitalization and subsequent length of recovery after elective knee arthroplasty have decreased. We hypothesized same-day discharge following either a unicompartmental (UKA) or total knee arthroplasty (TKA) in an unselected group of patients would not result in a higher perioperative complication rate than standard-length hospitalization when following a comprehensive perioperative clinical pathway, including preoperative teaching, regional anesthesia, preemptive oral analgesia, preemptive antiemetics, and a rapid rehabilitation protocol. We prospectively followed 111 of all 121 patients who had primary knee arthroplasty completed by noon and who agreed to be followed prospectively; 25 had UKA and 86 TKA. Of the 111 patients, 104 (94%, 24 with UKA and 80 with TKA) met discharge criteria and were discharged directly to home the day of surgery. Nausea requiring additional treatment before discharge was the most common reason for a delay in discharge. There were four (3.6%) readmissions (all with TKA) and one emergency room visit without readmission (in a patient with a TKA) within the first week after surgery, while there were four subsequent readmissions (3.6%) and one additional emergency room visit without readmission within three months of surgery, all among patients undergoing TKA. There were no deaths, cardiac events, or pulmonary complications during this study. Outpatient knee arthroplasty surgery is feasible in a large percentage of patients yet early readmissions may be decreased with a prolonged hospitalization. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Oviedo Baena, Ana M; Moeschler, Susan M; Smith, Hugh M; Duncan, Christopher M; Schroeder, Darrell R; Kopp, Sandra L
2015-11-01
To determine the demographic characteristics of patients undergoing primary total knee arthroplasty during the years 1989, 1999, and 2009 at our institution and determine whether their characteristics mirror the changing US demographic characteristics. Retrospective chart review of patients and prospective survey of experienced anesthesia providers in total knee arthroplasty. Tertiary care academic medical center. All patients 18 years and older who underwent unilateral primary total knee arthroplasty in 1989, 1999, and 2009 were identified through the Mayo Clinic Total Joint Registry. For each year, 200 patients were randomly selected. The demographic characteristics, comorbidities, perioperative care, and postoperative outcomes of patients, as well as survey responses from experienced anesthesia providers. During the 3 study years, a total of 591 patients were included for analysis. A statistically significant increase in body mass index (BMI) was observed over time in patients undergoing primary total knee arthroplasty (average BMI, 29.01 in 1989, 31.32 in 1999, and 32.32 in 2009 [P < .001]). Despite the increase in patient comorbidities, the percentage of patients who had postoperative complications decreased over time (P = .003), and postoperative disposition (general medicine ward vs intensive care unit) did not change. Our provider survey received a 76% response rate. In total, 82% of anesthesia providers who responded to the survey perceived that both BMI and the number of comorbidities had increased. Of survey respondents, 67% state that they have modified their perioperative anesthesia care because of changes in body habitus and patient comorbidities. The number of obese patients with comorbidities who present for total knee arthroplasty at our institution has increased over the past 20 years. Despite this fact, a reduction was detected in postoperative complications. Copyright © 2015 Elsevier Inc. All rights reserved.
Yu, Xiu-chun; Xu, Ming; Song, Ruo-xian; Fu, Zhi-hou; Liu, Xiao-ping
2010-08-01
To study the long-term outcomes and complications of giant cell tumors around the knee treated with en bloc resection and reconstruction with prosthesis. From January 1991 to March 2005, 19 patients (11 men, 8 women, average age 35.4 years) were treated in our hospital with en bloc resection and reconstruction with domestic prosthesis (15 hinge knee and 4 rotating-hinge knee). The distal femur was involved in 12 and the proximal tibia in 7 cases. Nine tumors were primary and 10 recurrent. All cases were Campanacci grade III. The affected limb functions were evaluated by the Musculoskeletal Tumor Society scoring system. All patients underwent operation successfully with no complications. The mean follow-up time was 128.9 months (60 to 216 months). Apart from one patient who underwent amputation because of wound infection two years after reoperation, the range of knee motion of 18 patients was 30°-110°. The mean functional score of the affected limb was 22.7 (15 to 27 points). The length of the lower extremities was equal in nine cases; the affected limb was 2-9 cm shorter in the other ten cases. Prosthesis fracture and loosening developed in one, prosthesis aseptic loosening in three, and delayed deep infection and prosthesis loosening in two cases. The prosthesis loosening rate was 31.6%. One patient developed a proximal femur fracture. En bloc resection and reconstruction with prosthesis is a feasible method for treating giant cell tumor of bone around the knee. Complications related to the prosthesis, mainly prosthesis loosening and limb shortening, increase gradually with longer survival time. © 2010 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.
Nussenbaum, Fernando D; Rodriguez-Quintana, David; Fish, Sara M; Green, David M; Cahill, Catherine W
2018-01-01
Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common procedures with a risk of complications. Attempting to minimize complications, our institution implemented preoperative screening criteria for patients undergoing elective total joint replacement. Our study aimed to determine if screening criteria lowered total complications and/or surgical site infections (SSI). Two groups of consecutive patients undergoing TKA and THA at a single Veterans Affairs facility were evaluated prior to and after implementation of screening criteria, 520 and 475 respectively. Screening criteria included hemoglobin A1c ≤7, hemoglobin ≥11, body mass index ≤35, and albumin ≥3.5. Groups were analyzed for demographics, preoperative comorbidities, and postoperative complications. Rates of total complications and SSI were compared. Average follow-up was at least 2 years with minimum of 1 year. Demographics and comorbidities outside the screening criteria were similar. Total complication rate was reduced from 35.4% to 14.8% (P < .01) after implementation of screening criteria. For TKA, total complications were reduced from 33.1% to 15.0% (P < .01) and for THA they were reduced from 42.4% to 14.2% (P < .01). SSI rates for combined TKA and THA were reduced from 4.4% to 1.3% (P < .01). For knees, SSI was reduced from 4.6% to 1.3% (P = .01) and was statistically significant. For THA, SSI decreased from 3.8% to 1.2% (P < .05). Our institution saw a statistically significant decrease in both SSI and total complications following implementation of preoperative screening criteria for elective TKA and THA. Published by Elsevier Inc.
What Is the Impact of Smoking on Revision Total Knee Arthroplasty?
Bedard, Nicholas A; Dowdle, S Blake; Wilkinson, Brandon G; Duchman, Kyle R; Gao, Yubo; Callaghan, John J
2018-07-01
There is a paucity of literature evaluating the impact of smoking on revision arthroplasty procedures. The purpose of this study was to identify the effect of smoking on complications after revision total knee arthroplasty (rTKA). We queried the American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database to identify patients who underwent rTKA between 2006 and 2014. Patients were divided into current smokers and nonsmokers according to the NSQIP definitions. Each cohort was compared in terms of demographic data, preoperative comorbidities, and operative time. Infection end points were created from composite surgical site infection variables defined by the NSQIP database. Multivariate logistic regression analysis was utilized to adjust for confounding variables and calculate adjusted odds ratios (ORs) and associated 95% confidence intervals (95% CIs). In total, 8776 patients underwent rTKA. Of these patients, 11.6% were current smokers. Univariate analyses demonstrated that smokers had a higher rate of any wound complication (3.8% vs 1.8%, P < .0001), deep infection (2.5% vs 1.0%, P < .0001), pneumonia (1.3% vs 0.4%, P < .0001), and reoperation (5.0% vs 3.1%, P = .001) compared to nonsmokers undergoing revision total knee arthroplasty. Multivariate analysis identified current smokers as being at a significantly increased risk of any wound complication (OR 2.1; 95% CI 1.4-3.1) and deep infection (OR 2.1, 95% CI 1.2-3.6) after rTKA. This study demonstrates that smoking significantly increases the risk of infection, wound complications, and reoperation after rTKA. The results are even more magnified for revision procedures compared to published effects of smoking on primary total knee arthroplasty complications. Further research is needed regarding the impact of smoking cessation on mitigation of these observed risks. Copyright © 2018 Elsevier Inc. All rights reserved.
Pichler, Lukas; Poeran, Jashvant; Zubizarreta, Nicole; Cozowicz, Crispiana; Sun, Eric C; Mazumdar, Madhu; Memtsoudis, Stavros G
2018-05-21
Although some trials suggest benefits of liposomal bupivacaine, data on real-world use and effectiveness is lacking. This study analyzed the impact of liposomal bupivacaine use (regardless of administration route) on inpatient opioid prescription, resource utilization, and opioid-related complications among patients undergoing total knee arthroplasties with a peripheral nerve block. It was hypothesized that liposomal bupivacaine has limited clinical influence on the studied outcomes. The study included data on 88,830 total knee arthroplasties performed with a peripheral nerve block (Premier Healthcare Database 2013 to 2016). Multilevel multivariable regressions measured associations between use of liposomal bupivacaine and (1) inpatient opioid prescription (extracted from billing) and (2) length of stay, cost of hospitalization, as well as opioid-related complications. To reflect the difference between statistical and clinical significance, a relative change of -15% in outcomes was assumed to be clinically important. Overall, liposomal bupivacaine was used in 21.2% (n = 18,817) of patients that underwent a total knee arthroplasty with a peripheral nerve block. Liposomal bupivacaine use was not associated with a clinically meaningful reduction in inpatient opioid prescription (group median, 253 mg of oral morphine equivalents, adjusted effect -9.3% CI -11.1%, -7.5%; P < 0.0001) and length of stay (group median, 3 days, adjusted effect -8.8% CI -10.1%, -7.5%; P < 0.0001) with no effect on cost of hospitalization. Most importantly, liposomal bupivacaine use was not associated with decreased odds for opioid-related complications. Liposomal bupivacaine was not associated with a clinically relevant improvement in inpatient opioid prescription, resource utilization, or opioid-related complications in patients who received modern pain management including a peripheral nerve block.
A discrete mechanics approach to dislocation dynamics in BCC crystals
NASA Astrophysics Data System (ADS)
Ramasubramaniam, A.; Ariza, M. P.; Ortiz, M.
2007-03-01
A discrete mechanics approach to modeling the dynamics of dislocations in BCC single crystals is presented. Ideas are borrowed from discrete differential calculus and algebraic topology and suitably adapted to crystal lattices. In particular, the extension of a crystal lattice to a CW complex allows for convenient manipulation of forms and fields defined over the crystal. Dislocations are treated within the theory as energy-minimizing structures that lead to locally lattice-invariant but globally incompatible eigendeformations. The discrete nature of the theory eliminates the need for regularization of the core singularity and inherently allows for dislocation reactions and complicated topological transitions. The quantization of slip to integer multiples of the Burgers' vector leads to a large integer optimization problem. A novel approach to solving this NP-hard problem based on considerations of metastability is proposed. A numerical example that applies the method to study the emanation of dislocation loops from a point source of dilatation in a large BCC crystal is presented. The structure and energetics of BCC screw dislocation cores, as obtained via the present formulation, are also considered and shown to be in good agreement with available atomistic studies. The method thus provides a realistic avenue for mesoscale simulations of dislocation based crystal plasticity with fully atomistic resolution.
Xu, Yong; Li, Feng; Guan, Hanfeng; Xiong, Wei
2015-01-01
Abstract Posterior atlantoaxial dislocation without odontoid fracture is extremely rare and often results in fatal spinal cord injury. According to the reported literature, all cases presented mild or no neurologic deficit, with no definite relation to upper spinal cord injury. Little is reported about traumatic posterior atlantoaxial dislocation, with incomplete quadriplegia associated with a spinal cord injury. We present a case of posterior atlantoaxial dislocation without associated fracture, but with quadriplegia, and accompanying epidural hematoma and subarachnoid hemorrhage. The patient underwent gentle traction in the neutral position until repeated cranial computed tomography revealed no progression of the epidural hematoma. Thereafter, the atlantoaxial dislocation was reduced by using partial odontoidectomy via a video-assisted transcervical approach and maintained with posterior polyaxial screw-rod constructs and an autograft. Neurological status improved immediately after surgery, and the patient recovered completely after 1 year. Posterior fusion followed by closed reduction is the superior strategy for posterior atlantoaxial dislocation without odontoid fracture, according to literature. But for cases with severe neurological deficit, open reduction may be the safest choice to avoid the lethal complication of overdistraction of the spinal cord. Also, open reduction and posterior srew-rod fixation are safe and convenient strategies in dealing with traumatic posterior atlantoaxial dislocation patients with neurological deficit. PMID:26512572
Burke, Neil G; Green, Connor; McHugh, Gavin; McGolderick, Niall; Kilcoyne, Carol; Kenny, Patrick
2012-08-01
It is important to reduce potential wound complications in total hip and total knee arthroplasty procedures. The purpose of this study was to compare the jubilee dressing method to a standard adhesive dressing. 124 patients (62 total hip replacements and 62 total knee replacements) were randomly selected to have either a standard adhesive dressing or jubilee method dressing. The number of dressing changes, incidence of blistering, leakage, appearance of inflammation, infection rate and the average stay in hospital was recorded for each patient. The jubilee dressing significantly reduced the rate of blistering, leakage and number of dressing changes when compare to a traditional adhesive dressing (p < 0.05). The rate of inflammation and average length of stay in hospital was not significantly different between the two groups. The authors recommend the use of this dressing for total hip and total knee arthroplasty procedures due to the associated lower complication rate. Copyright © 2012 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Traumatic dislocation of the S1 polyaxial pedicle screw head: a case report.
Du Plessis, Pieter N B; Lau, Bernard P H; Hey, Hwee Weng Dennis
2017-03-01
Polyaxial screw head dislocation in the absence of a manufacture defect is extremely rare and represents a biomechanical overload of the screw, leading to early failure. A 58-year-old gentleman underwent instrumented fusion using polyaxial pedicle screws-titanium rod construct with interbody cage for spondylolytic spondylolisthesis at the L5/S1 level. He attempted to bend forward ten days after the surgery which resulted in a dislocation of the right S1 polyaxial screw head from the screw shank with recurrence of symptoms. He underwent revision surgery uneventfully. This case highlights the need to pay particular attention to the strength of fixation and the amount of release to avoid such a complication.
Sastre, Sergi; Dada, Michelle; Santos, Simon; Lozano, Lluis; Alemany, Xavier; Peidro, Lluis
2015-03-01
The objective of this manuscript is to show an effective, easier and cheaper way to reduce acute acromioclavicular (AC) dislocation type III and V (Rockwood classification). Numerous procedures have been described for surgical management of acromioclavicular joint disruption. Newest devices involve an arthroscopic technique that allows nonrigid anatomic fixation of the acromioclavicular joint. Arthroscopically assisted treatment of acute AC joint dislocation is advantageous because it provides good clinical results and few complications. It also allows reviewing glenohumeral associated lesions. This surgical technique requires no specific implants to achieve a correct AC reduction. Actually, economical advantages are very important factors to decide the use of determinate surgical techniques.
Haughom, Bryan D; Erickson, Brandon J; Hellman, Michael D; Jacobs, Joshua J
2015-08-01
Although metal-on-metal (MoM) bearing surfaces provide low rates of volumetric wear and increased stability, evidence suggests that certain MoM hip arthroplasties have high rates of complication and failure. Some evidence indicates that women have higher rates of failure compared with men; however, the orthopaedic literature as a whole has poorly reported such complications stratified by gender. This systematic review aimed to: (1) compare the rate of adverse local tissue reaction (ALTR); (2) dislocation; (3) aseptic loosening; and (4) revision between men and women undergoing primary MoM hip resurfacing arthroplasty (HRA). Systematic MEDLINE and EMBASE searches identified all level I to III articles published in peer-reviewed journals, reporting on the outcomes of interest, for MoM HRA. Articles were limited to those with 2-year followup that reported outcomes by gender. Ten articles met inclusion criteria. Study quality was evaluated using the Modified Coleman Methodology Score; the overall quality was poor. Heterogeneity and bias were analyzed using a Mantel-Haenszel statistical method. Women demonstrated an increased odds of developing ALTR (odds ratio [OR], 5.70 [2.71-11.98]; p<0.001), dislocation (OR, 3.04 [1.2-7.5], p=0.02), aseptic loosening (OR, 3.18 [2.21-4.58], p<0.001), and revision (OR, 2.50 [2.25-2.78], p<0.001) after primary MoM HRA. A systematic review of the currently available literature reveals a higher rate of complications (ALTR, dislocation, aseptic loosening, and revision) after MoM HRA in women compared with men. Although femoral head size has been frequently implicated as a prime factor in the higher rate of complication in women, further research is necessary to specifically probe this relationship. Retrospective studies of data available (eg, registry data) should be undertaken, and moving forward studies should report outcomes by gender (particularly complications). Level III, therapeutic study.
Lawsuits After Primary and Revision Total Hip Arthroplasties: A Malpractice Claims Analysis.
Patterson, Diana C; Grelsamer, Ronald P; Bronson, Michael J; Moucha, Calin S
2017-10-01
As the prevalence of total hip arthroplasty (THA) expands, so too will complications and patient dissatisfaction. The goal of this study was to identify the common etiologies of malpractice suits and costs of claims after primary and revision THAs. Analysis of 115 malpractice claims filed for alleged neglectful primary and revision THA surgeries by orthopedic surgeons insured by a large New York state malpractice carrier between 1983 and 2011. The incidence of malpractice claims filed for negligent THA procedures is only 0.15% per year in our population. In primary cases, nerve injury ("foot drop") was the most frequent allegation with 27 claims. Negligent surgery causing dislocation was alleged in 18 and leg length discrepancy in 14. Medical complications were also reported, including 3 thromboembolic events and 6 deaths. In revision cases, dislocation and infection were the most common source of suits. The average indemnity payment was $386,153 and the largest single settlement was $4.1 million for an arterial injury resulting in amputation after a primary hip replacement. The average litigation cost to the insurer was $61,833. Nerve injury, dislocation, and leg length discrepancy are the most common reason for malpractice after primary THA. Orthopedic surgeons should continue to focus on minimizing the occurrence of these complications while adequately incorporating details about the risks and limitations of surgery into their preoperative education. Copyright © 2017 Elsevier Inc. All rights reserved.
Kolb, Werner; Guhlmann, Hanno; Windisch, Christoph; Marx, Frank; Koller, Heiko; Kolb, Klaus
2010-09-01
The complication rate of periprosthetic femoral fractures above well-fixed total knee arthroplasties is high. The Less Invasive Stabilization System (LISS) was introduced to reduce surgical dissections at the fracture site. The purpose of this retrospective study was to evaluate the midterm functional outcome of a group of patients with periprosthetic fractures above well-fixed total knee arthroplasties treated with the LISS. Between January 1999 and June 2004, 23 consecutive patients (all women) with periprosthetic fractures above well-fixed total knee arthroplasties were treated with the LISS. The mean age was 77 years (range, 61-90 years). Nineteen of the patients (83%) were seen after a midterm follow-up of 46 months (range, 26-67 months). Three patients (13%) died, and one patient (4%) was lost to follow-up. A proximal screw pull-out of the internal fixator occurred in one patient (4%). All fractures healed within a mean of 14 weeks (range, 9-21 weeks). No bone graft was required. There were two delayed unions, no nonunions or infections. One patient (4%) had a malalignment with 7° varus. The mean range of motion was 102° (range, 65-120°). The mean knee score of the Knee Society was 81 points (range, 65-90 points), and the mean function score of the Knee Society was 56 points (range, 35-90 points). We found that a minimally invasive, locked plating system permitted stable fixation, early knee motion with good midterm results, and minimal complications. These techniques should be used in place of less stable and more invasive methods.
2012-01-01
Background Total knee arthroplasty (TKA) is a common form of treatment to relieve pain and improve function in cases of rheumatoid arthritis (RA). Good clinical outcomes have been reported with a variety of TKA prostheses. The cementless Hi-Tech Knee II cruciate-retaining (CR)-type prosthesis, which has 6 fins at the anterior of the femoral component, posterior cruciate ligament (PCL) retention, flat-on-flat surface component geometry, all-polyethylene patella, strong initial fixation by the center screw of the tibial base plate, 10 layers of titanium alloy fiber mesh, and direct compression molded ultra high molecular weight polyethylene (UHMWPE), is appropriate for TKA in the Japanese knee. The present study was performed to evaluate the clinical results of primary TKA in RA using the cementless Hi-Tech Knee II CR-type prosthesis. Materials and methods We performed 32 consecutive primary TKAs using cementless Hi-Tech Knee II CR-type prosthesis in 31 RA patients. The average follow-up period was 8 years 3 months. Clinical evaluations were performed according to the American Knee Society (KS) system, knee score, function score, radiographic evaluation, and complications. Results The mean postoperative maximum flexion angle was 115.6°, and the KS knee score and function score improved to 88 and 70 after surgery, respectively. Complications, such as infection, occurred in 1 patient and revision surgery was performed. There were no cases of loosening in this cohort, and prosthesis survival rate was 96.9% at 12 years postoperatively. Conclusion These results suggest that TKA using the cementless Hi-Tech Knee II CR-type prosthesis is a very effective form of treatment in RA patients at 5 to 12 years postoperatively. Further long-term follow-up studies are required to determine the ultimate utility of this type of prosthesis. PMID:22356935
Chen, Fang-Hu; Zhao, Xiao-Ping; Zheng, Wen-Biao; Zeng, Han-Bing; Ran, Bo; Huang, Hui; Wang, Hai-Bao
2013-05-01
To observe the clinical therapeutic effects of sternoclavicular hook plate for the treatment of sternoclavicular joint dislocation. From June 2010 to June 2012, 7 patients with sternoclavicular joint dislocation were treated with sternoclavicular hook plate fixation. Among the 7 patients, 5 patients were male and 2 patients were female, and the average age was 42.3 years, ranging from 38 to 54 years. The course of the disease ranged from 1 to 4 weeks. All the patients had trauma history. The clinical manifestations included: obvious swelling and pain of sternoclavicular joint, restricted shoulder joint activity. The sternoclavicular joint dislocation was proved by preoperative X-ray and CT. The postoperative curative effect was evaluated according to Rockwood scoring method. According to Rockwood scoring method, the excellent results obtained in 6 cases, good in 1. There were no complications such as internal fixation loosening or broken, second dislocation, pain in the sternoclavicular joint, and deformity. The function of shoulder joint was good, and the limb activity was free and no pain appeared. The sternoclavicular hook plate for the treatment of sternoclavicular joint dislocation has follow advantages: simple procedure, stable fixation, definite therapeutic effects.
Hip arthroscopy versus open surgical dislocation for femoroacetabular impingement
Zhang, Dagang; Chen, Long; Wang, Guanglin
2016-01-01
Abstract Background: This meta-analysis aims to evaluate the efficacy and safety of hip arthroscopy versus open surgical dislocation for treating femoroacetabular impingement (FAI) through published clinical trials. Methods: We conducted a comprehensive literature search using PUBMED, EMBASE, and the Cochrane Central Register of Controlled Trials databases for relevant studies on hip arthroscopy and open surgical dislocation as treatment options for FAI. Results: Compared with open surgical dislocation, hip arthroscopy resulted in significantly higher Nonarthritic Hip Scores (NAHS) at 3- and 12-month follow-ups, a significant improvement in NAHS from preoperation to 3 months postoperation, and a significantly lower reoperation rate. Open surgical dislocation resulted in a significantly improved alpha angle by the Dunn view in patients with cam osteoplasty from preoperation to postoperation, compared with hip arthroscopy. This meta-analysis demonstrated no significant differences in the modified Harris Hip Score, Hip Outcome Score-Activities of Daily Living, or Hip Outcome Score-Sport Specific Subscale at 12 months of follow-up, or in complications (including nerve damage, wound infection, and wound dehiscence). Conclusion: Hip arthroscopy resulted in higher NAHS and lower reoperation rates, but had less improvement in alpha angle in patients with cam osteoplasty, than open surgical dislocation. PMID:27741133
Brignardello-Petersen, Romina; Guyatt, Gordon H; Buchbinder, Rachelle; Poolman, Rudolf W; Schandelmaier, Stefan; Chang, Yaping; Sadeghirad, Behnam; Evaniew, Nathan; Vandvik, Per O
2017-05-11
To determine the effects and complications of arthroscopic surgery compared with conservative management strategies in patients with degenerative knee disease. Systematic review. Pain, function, adverse events. MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials (CENTRAL), Google Scholar and Open Grey up to August 2016. For effects, randomised clinical trials (RCTs) comparing arthroscopic surgery with a conservative management strategy (including sham surgery) in patients with degenerative knee disease. For complications, RCTs and observational studies. Two reviewers independently extracted data and assessed risk of bias for patient-important outcomes. A parallel guideline committee ( BMJ Rapid Recommendations) provided input on the design and interpretation of the systematic review, including selection of patient-important outcomes. We used the GRADE approach to rate the certainty (quality) of the evidence. We included 13 RCTs and 12 observational studies. With respect to pain, the review identified high-certainty evidence that knee arthroscopy results in a very small reduction in pain up to 3 months (mean difference =5.4 on a 100-point scale, 95% CI 2.0 to 8.8) and very small or no pain reduction up to 2 years (mean difference =3.1, 95% CI -0.2 to 6.4) when compared with conservative management. With respect to function, the review identified moderate-certainty evidence that knee arthroscopy results in a very small improvement in the short term (mean difference =4.9 on a 100-point scale, 95% CI 1.5 to 8.4) and very small or no improved function up to 2 years (mean difference =3.2, 95% CI -0.5 to 6.8). Alternative presentations of magnitude of effect, and associated sensitivity analyses, were consistent with the findings of the primary analysis. Low-quality evidence suggested a very low probability of serious complications after knee arthroscopy. Over the long term, patients who undergo knee arthroscopy versus those who receive conservative management strategies do not have important benefits in pain or function. PROSPERO CRD42016046242. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Brignardello-Petersen, Romina; Guyatt, Gordon H; Buchbinder, Rachelle; Poolman, Rudolf W; Chang, Yaping; Sadeghirad, Behnam; Evaniew, Nathan; Vandvik, Per O
2017-01-01
Objective To determine the effects and complications of arthroscopic surgery compared with conservative management strategies in patients with degenerative knee disease. Design Systematic review. Main outcome measures Pain, function, adverse events. Data sources MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials (CENTRAL), Google Scholar and Open Grey up to August 2016. Eligibility criteria For effects, randomised clinical trials (RCTs) comparing arthroscopic surgery with a conservative management strategy (including sham surgery) in patients with degenerative knee disease. For complications, RCTs and observational studies. Review methods Two reviewers independently extracted data and assessed risk of bias for patient-important outcomes. A parallel guideline committee (BMJ Rapid Recommendations) provided input on the design and interpretation of the systematic review, including selection of patient-important outcomes. We used the GRADE approach to rate the certainty (quality) of the evidence. Results We included 13 RCTs and 12 observational studies. With respect to pain, the review identified high-certainty evidence that knee arthroscopy results in a very small reduction in pain up to 3 months (mean difference =5.4 on a 100-point scale, 95% CI 2.0 to 8.8) and very small or no pain reduction up to 2 years (mean difference =3.1, 95% CI −0.2 to 6.4) when compared with conservative management. With respect to function, the review identified moderate-certainty evidence that knee arthroscopy results in a very small improvement in the short term (mean difference =4.9 on a 100-point scale, 95% CI 1.5 to 8.4) and very small or no improved function up to 2 years (mean difference =3.2, 95% CI −0.5 to 6.8). Alternative presentations of magnitude of effect, and associated sensitivity analyses, were consistent with the findings of the primary analysis. Low-quality evidence suggested a very low probability of serious complications after knee arthroscopy. Conclusions Over the long term, patients who undergo knee arthroscopy versus those who receive conservative management strategies do not have important benefits in pain or function. Trial registration number PROSPERO CRD42016046242. PMID:28495819
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weinberger, Christopher R.; Tucker, Garritt J.; Foiles, Stephen M.
2013-02-01
It is well known that screw dislocation motion dominates the plastic deformation in body-centered-cubic metals at low temperatures. The nature of the nonplanar structure of screw dislocations gives rise to high lattice friction, which results in strong temperature and strain rate dependence of plastic flow. Thus the nature of the Peierls potential, which is responsible for the high lattice resistance, is an important physical property of the material. However, current empirical potentials give a complicated picture of the Peierls potential. Here, we investigate the nature of the Peierls potential using density functional theory in the bcc transition metals. The resultsmore » show that the shape of the Peierls potential is sinusoidal for every material investigated. Furthermore, we show that the magnitude of the potential scales strongly with the energy per unit length of the screw dislocation in the material.« less
[Arthrodesis following revision of a knee endoprosthesis. Literature review 1984-1994].
Kohn, D; Schmolke, S
1996-04-01
Two percent of primary and 8% of revision total knee replacements are followed by arthrodesis. Today knee arthrodesis is the most important salvage procedure after failed total knee arthroplasty, resection arthroplasty and above-the-knee amputation being the only alternatives. Analysis of the literature between 1984 and 1994 revealed 533 cases treated with arthrodesis of the knee; 403 were done after failed total knee arthroplasty. The fusion rate was 74%. External fixation, intramedullary nail, plates and combinations of these are currently used for fixation. The literature and an analysis of our own patients from 1988 to 1994 showed that arthrodesis after failed arthroplasty is a difficult procedure, and complications often occur. Bone loss of the distal femur and proximal tibia is the one most important prognostic factor. A new classification system for bone loss is presented.
Burrus, M Tyrrell; Cancienne, Jourdan M; Boatright, Jeffrey D; Yang, Scott; Brockmeier, Stephen F; Werner, Brian C
2018-02-01
Humeral head avascular necrosis (AVN) of differing etiologies may lead to shoulder arthroplasty due to subchondral bone collapse and deformity of the articular surface. There have been no large studies evaluating the complications for these patients after they undergo total shoulder arthroplasty (TSA). The first objective of this study is to evaluate the complication rate after TSA in patients with humeral head AVN. The secondary objective is to compare the complication rates among the different etiologies of the AVN. Patients who underwent TSA were identified in the PearlDiver database using ICD-9 codes. Patients who underwent shoulder arthroplasty for humeral head AVN were identified using ICD-9 codes and were subclassified according to AVN etiology (posttraumatic, alcohol use, chronic steroid use, and idiopathic). Complications evaluated included postoperative infection within 6 months, dislocation within 1 year, revision shoulder arthroplasty up to 8 years postoperatively, shoulder stiffness within 1 year, and periprosthetic fracture within 1 year and systemic complications within 3 months. Postoperative complication rates were compared to controls. The study cohorts included 4129 TSA patients with AVN with 141,778 control TSA patients. Patients with posttraumatic AVN were significantly more likely to have a postoperative infection (OR 2.47, P < 0.001), dislocation (OR 1.45, P = 0.029), revision surgery (OR 1.53, P = 0.001), stiffness (OR 1.24, P = 0.042), and systemic complication (OR 1.49, P < 0.001). Steroid-associated AVN was associated with a significantly increased risk for a postoperative infection (OR 1.72, P = 0.004), revision surgery (OR 1.33, P = 0.040), fracture (OR 2.76, P = 0.002), and systemic complication (OR 1.59, P < 0.001). Idiopathic and alcohol-associated AVN were not significantly associated with any of the postoperative evaluated complications. TSA in patients with humeral head AVN is associated with significantly increased rates of numerous postoperative complications compared to patients without a diagnosis of AVN, including infection, dislocation, revision arthroplasty, stiffness, periprosthetic fracture, and medical complications. Specifically, AVN due to steroid use or from a posttraumatic cause appears to be associated with the statistically highest rates of postoperative TSA complications. Given these findings, orthopedic surgeons should be increasingly aware of this association, which should influence the shared decision-making process of undergoing TSA in patients with humeral head AVN.
Kalia, Anoop; Khatri, Kavin; Singh, Jagdeep; Bansal, Kapil; Sagy, Mohammed
2016-01-01
Introduction: The migration of circlage wires used in tension band wiring construct of patella fractures in the posterior soft tissue envelope surrounding the knee joint has been rarely reported. Case Presentation: A 60-year-old woman presented to us with pain over medial aspect of right knee joint. She underwent open reduction and internal fixation for a patellar fracture which she sustained 4 years back and subsequently underwent kirschner wire(k wire) removal for the same around 2 years back. X-rays of the knee joint shows that the circlage wire used in tension band construct which was left in place had broken into multiple pieces and was lying in the soft tissue envelope surrounding the knee joint and one piece migrate to the popliteal fossa. On examination patient did not had distal neuro-vascular deficit. The pain of the patient was due to the osteo-arthritic changes in her medial side of knee joint rather than broken wire pieces. Patient was advised to undergo total knee replacement along with subsequent removal of broken wires but patient refused for any type of surgery and is kept on regular follow up Conclusion: This case report summarizes a rare complication resulting from hardware failure used for fixing patella fractures and throws a light on potential unwarned complications due to broken wires along with early recogonition and removal of broken hardware by surgeons. PMID:28116277
Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan
2014-01-01
AIM To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation. METHODS Non-comparative retrospective observational case series. Participants: 30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi'an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs) were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. Main outcome measures: visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations. RESULTS The follow-up time was 11-36mo (21.4±7.13). Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL dislocation, and endophthalmitis. CONCLUSION To take early treatment of traumatic lens subluxation/dislocation in patients with secondary glaucoma by individual surgical plan based on the different eye conditions would be safe and effective, which can effectively control the intraocular pressure and restore some vision. PMID:24790868
Fungal Periprosthetic Joint Infection in Total Knee Arthroplasty: A Systematic Review
Jakobs, Oliver; Schoof, Benjamin; Klatte, Till Orla; Schmidl, Stefan; Fensky, Florian; Guenther, Daniel; Frommelt, Lars; Gehrke, Thorsten; Gebauer, Matthias
2015-01-01
Fungal periprosthetic joint infection (PJI) is a rare but devastating complication following total knee arthroplasty (TKA). A standardized procedure regarding an accurate treatment of this serious complication of knee arthroplasty is lacking. In this systematic review, we collected data from 36 studies with a total of 45 reported cases of a TKA complicated by a fungal PJI. Subsequently, an analysis focusing on diagnostic, medicaments and surgical procedures in the pre-, intra- and postoperative period was performed. Candida spp. accounts for about 80% (36 out of 45 cases) of fungal PJIs and is therefore the most frequently reported pathogen. A systemic antifungal therapy was administered in all but one patient whereas a local antifungal therapy, e.g. the use of an impregnated spacer, is of inferior relevance. Resection arthroplasty with delayed re-implantation (two-stage revision) was the surgical treatment of choice. However, in 50% of all reported cases the surgical therapy was heterogeneous. The outcome under a combined therapy was moderate with recurrent fungal PJI in 11 patients and subsequent bacterial PJI as a main complication in 5 patients. In summary, this systematic review integrates data from up to date 45 reported cases of a fungal PJI of a TKA. On the basis of the current literature strategies for the treatment of this devastating complication after TKA are discussed. PMID:25874061
[Effect factors analysis of knee function recovery after distal femoral fracture operation].
Bei, Chaoyong; Wang, Ruiying; Tang, Jicun; Li, Qiang
2009-09-01
To investigate the effect factors of knee function recovery after operation in distal femoral fractures. From January 2001 to May 2007, 92 cases of distal femoral fracture were treated. There were 50 males and 42 females, aged 20-77 years old (average 46.7 years old). Fracture was caused by traffic accident in 48 cases, by falling from height in 26 cases, by bruise in 12 cases and by tumble in 6 cases. According to Müller's Fracture classification, there were 29 cases of type A, 12 cases of type B and 51 cases of type C. According to American Society of Anesthesiologists (ASA) classification, there were 21 cases of grade I, 39 cases of grade II, 24 cases of grade III, and 8 cases of grade IV. The time from injury to operation was 4 hours to 24 days with an average of 7 days. Anatomical plate was used in 43 cases, retrograde interlocking intramedullary nail in 37 cases, and bone screws, bolts and internal fixation with Kirschner pins in 12 cases. After operation, the HSS knee function score was used to evaluate efficacy. Ten related factors were applied for statistical analysis, to knee function recovery after operation in distal femoral fractures, such as age, sex, preoperative ASA classification, injury to surgery time, fracture type, treatment, reduction quality, functional exercise after operation, whether or not CPM functional training and postoperative complications. Wound healed by first intention in 88 cases, infection occurred in 4 cases. All patients followed up 16-32 months with an average of 23.1 months. Clinical union of fracture was achieved within 3-7 months after operation. Extensor device adhesions and the scope of activities of <80 degrees occurred in 29 cases, traumatic arthritis in 25 cases, postoperative fracture displacement in 6 cases, mild knee varus or valgus in 7 cases and implant loosening in 6 cases. According to HSS knee function score, the results were excellent in 52 cases, good in 15 cases, fair in 10 cases and poor in 15 cases with an excellent and good rate of 72.83%. Single factor analysis showed that age, preoperative ASA classification, fracture type, reduction quality, whether or not CPM functional exercise, and postoperative complications were significantly in knee function recovery (P < 0.05). logistic regression analysis showed that the fracture type, quality of reduction, whether or not CPM functional exercise, and age were major factors in the knee joint function recovery. Age, preoperative ASA classification, fracture type, reduction quality, and whether or not CPM functional training, postoperative complications factors may affect the knee joint function recovery. Adjustment to the patient's preoperative physical status, fractures anatomic reduction and firm fixation, early postoperative active and passive functional exercises, less postoperative complications can maximize the restoration of knee joint function.
Atraumatic haemarthrosis following total knee replacement treated with selective embolisation.
Karataglis, Dimitrios; Marlow, Duncan; Learmonth, Duncan J A
2006-06-01
Spontaneous haemarthrosis in the absence of anticoagulant medication or a bleeding disorder is a very rare complication after total knee arthroplasty. A case of recurrent spontaneous haemarthrosis following total knee replacement in a 69-year-old patient is reported. Angiography was used to aid the diagnosis. It demonstrated an abnormal blush of vessels around the anterior aspect of the knee joint, that was fed by genicular branches and a recurrent branch of the anterior tibial artery. Selective embolisation of the bleeding vessels with coils led to immediate control of the bleeding. No further recurrence of haemarthrosis has been recorded.
Kheir, Michael M; Rondon, Alexander J; Woolsey, Alexandra; Hansen, Heather; Tan, Timothy L; Parvizi, Javad
2018-05-01
A prior survey of members of the American Association of Hip and Knee Surgeons revealed that 78% of responding surgeons were named as a defendant in at least 1 lawsuit, and 69% of these lawsuits were dismissed or settled out of court. The most common sources of litigation were nerve injury, limb-length discrepancy, and infection. This study examined common reasons for lawsuits after total joint arthroplasty (TJA) in a single metropolitan area. A retrospective review of lawsuits filed between 2009 and 2015 in a 5-county metropolitan area was performed, including 30 hospitals and 113 TJA surgeons. Complaints underwent a manual review to determine the number of lawsuits and the specific allegations filed against each surgeon. Thirty-one (27.4%) surgeons were named as a defendant in at least 1 lawsuit. Eighty-three total lawsuits were filed during the period, 50 of which were dismissed or settled outside of court. Top reasons for lawsuits were, in descending order, infection, nerve injury, chronic pain, vascular injury, periprosthetic fracture, retention of foreign body, dislocation, limb-length discrepancy, venous thromboembolism, loosening, compartment syndrome, and other medical complaints. Infection appears to be the basis of most lawsuits after TJA. Surgeons should be aware of the potential for a lawsuit for complications and should strive to better communicate with patients regarding preoperative informed consent and disclosure after adverse events. Surgeons should minimize performing surgery in patients at high risk of complications, such as patients with a higher likelihood of developing postoperative infection or patients on chronic pain medications. Copyright © 2017 Elsevier Inc. All rights reserved.
Current concepts review: Fractures of the patella
Gwinner, Clemens; Märdian, Sven; Schwabe, Philipp; Schaser, Klaus-D.; Krapohl, Björn Dirk; Jung, Tobias M.
2016-01-01
Fractures of the patella account for about 1% of all skeletal injuries and can lead to profound impairment due to its crucial function in the extensor mechanism of the knee. Diagnosis is based on the injury mechanism, physical examination and radiological findings. While the clinical diagnosis is often distinct, there are numerous treatment options available. The type of treatment as well as the optimum timing of surgical intervention depends on the underlying fracture type, the associated soft tissue damage, patient factors (i.e. age, bone quality, activity level and compliance) and the stability of the extensor mechanism. Regardless of the treatment method an early rehabilitation is recommended in order to avoid contractures of the knee joint capsule and cartilage degeneration. For non-displaced and dislocated non-comminuted transverse patellar fractures (2-part) modified anterior tension band wiring is the treatment of choice and can be combined – due to its biomechanical superiority – with cannulated screw fixation. In severe comminuted fractures, open reduction and fixation with small fragment screws or new angular stable plates for anatomic restoration of the retropatellar surface and extension mechanism results in best outcome. Additional circular cerclage wiring using either typical metal cerclage wires or resorbable PDS/non-resorbable FiberWires increases fixation stability and decreases risk for re-dislocation. Distal avulsion fractures should be fixed with small fragment screws and should be protected by a transtibial McLaughlin cerclage. Partial or complete patellectomy should be regarded only as a very rare salvage operation due to its severe functional impairment. PMID:26816667
Mechanism and energetics of 〈c + a〉 dislocation cross-slip in hcp metals.
Wu, Zhaoxuan; Curtin, W A
2016-10-04
Hexagonal close-packed (hcp) metals such as Mg, Ti, and Zr are lightweight and/or durable metals with critical structural applications in the automotive (Mg), aerospace (Ti), and nuclear (Zr) industries. The hcp structure, however, brings significant complications in the mechanisms of plastic deformation, strengthening, and ductility, and these complications pose significant challenges in advancing the science and engineering of these metals. In hcp metals, generalized plasticity requires the activation of slip on pyramidal planes, but the structure, motion, and cross-slip of the associated [Formula: see text] dislocations are not well established even though they determine ductility and influence strengthening. Here, atomistic simulations in Mg reveal the unusual mechanism of [Formula: see text] dislocation cross-slip between pyramidal I and II planes, which occurs by cross-slip of the individual partial dislocations. The energy barrier is controlled by a fundamental step/jog energy and the near-core energy difference between pyramidal [Formula: see text] dislocations. The near-core energy difference can be changed by nonglide stresses, leading to tension-compression asymmetry and even a switch in absolute stability from one glide plane to the other, both features observed experimentally in Mg, Ti, and their alloys. The unique cross-slip mechanism is governed by common features of the generalized stacking fault energy surfaces of hcp pyramidal planes and is thus expected to be generic to all hcp metals. An analytical model is developed to predict the cross-slip barrier as a function of the near-core energy difference and applied stresses and quantifies the controlling features of cross-slip and pyramidal I/II stability across the family of hcp metals.
Mechanism and energetics of 〈c + a〉 dislocation cross-slip in hcp metals
Wu, Zhaoxuan; Curtin, W. A.
2016-01-01
Hexagonal close-packed (hcp) metals such as Mg, Ti, and Zr are lightweight and/or durable metals with critical structural applications in the automotive (Mg), aerospace (Ti), and nuclear (Zr) industries. The hcp structure, however, brings significant complications in the mechanisms of plastic deformation, strengthening, and ductility, and these complications pose significant challenges in advancing the science and engineering of these metals. In hcp metals, generalized plasticity requires the activation of slip on pyramidal planes, but the structure, motion, and cross-slip of the associated 〈c+a〉 dislocations are not well established even though they determine ductility and influence strengthening. Here, atomistic simulations in Mg reveal the unusual mechanism of 〈c+a〉 dislocation cross-slip between pyramidal I and II planes, which occurs by cross-slip of the individual partial dislocations. The energy barrier is controlled by a fundamental step/jog energy and the near-core energy difference between pyramidal 〈c+a〉 dislocations. The near-core energy difference can be changed by nonglide stresses, leading to tension–compression asymmetry and even a switch in absolute stability from one glide plane to the other, both features observed experimentally in Mg, Ti, and their alloys. The unique cross-slip mechanism is governed by common features of the generalized stacking fault energy surfaces of hcp pyramidal planes and is thus expected to be generic to all hcp metals. An analytical model is developed to predict the cross-slip barrier as a function of the near-core energy difference and applied stresses and quantifies the controlling features of cross-slip and pyramidal I/II stability across the family of hcp metals. PMID:27647908
Kellam, Patrick; Ostrum, Robert F
2016-01-01
To determine the incidence rate and associative factors for the development of avascular necrosis (AVN) and posttraumatic arthritis (PTA) after traumatic hip dislocation and time to reduction. A comprehensive search of databases including PubMed, Cochrane Database, and Embase through April 2014 for English articles reporting complications of AVN and PTA after hip dislocation was performed. Inclusion criteria were English-only studies, a patient population of adults, study outcomes of AVN and/or PTA reported, and articles reported at least type I dislocations. Two authors independently extracted data from the selected studies and the data collected were compared to verify agreement. Random-effects models were used for meta-analysis. The overall event rate of AVN and PTA was calculated and stratified based on Thompson-Epstein of the hip dislocation. Odds ratios were calculated for those articles that reported rates of AVN based on time to reduction. For anterior dislocations, the event rate for AVN ranged from 0.087 to 0.333, whereas the event rate for PTA ranged from 0.125 to 0.700. Analysis of posterior dislocations revealed that the event rate for AVN ranged from 0.106 to 0.430; additionally, the event rate for PTA ranged from 0.194 to 0.586. For posterior hip dislocations and type I and II anterior dislocations, the severity of the injury correlates with an increase in the development of AVN and PTA. The odds ratio of AVN for those hip dislocations reduced after 12 hours versus those reduced before 12 hours was 5.627. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Takkar, Brijesh; Azad, Rajvardhan; Azad, Shorya; Rathi, Anubha
2015-01-01
AIM To describe a new surgical technique for managing dislocated sclerotic cataractous lens. METHODS Six patients with advanced posteriorly dislocated cataracts were operated at a tertiary care centre and analyzed retrospectively. After standard 3 port 23 G pars plana vitrectomy and perfluorocarbon liquid (PFCL) injection, the dislocated white cataract was held with occlusion using phaco fragmatome and then chopped into smaller pieces with a sharp tipped chopper using 25 G chandelier endoilluminator. Each piece was emulsified individually. Following aspiration of PFCL, Fluid Air Exchange was done in all the cases and surgery completed uneventfully. RESULTS Best corrected visual acuity (BCVA) in all the patients was better than 6/12 after one month of follow up. No serious complications were noted till minimum 6mo of follow up. CONCLUSION Four port posterior segment nucleotomy with a chandelier endoilluminator, fragmatome and a chopper appears to be a safe, easy and effective procedure for managing dislocated sclerotic cataractous nuclei. Ultrasonic energy used and adverse thermal effects of the fragmatome on the sclera may be lesser. PMID:26309887
The Correlation Between Dislocations and Vacancy Defects Using Positron Annihilation Spectroscopy
NASA Astrophysics Data System (ADS)
Pang, Jinbiao; Li, Hui; Zhou, Kai; Wang, Zhu
2012-07-01
An analysis program for positron annihilation lifetime spectra is only applicable to isolated defects, but is of no use in the presence of defective correlations. Such limitations have long caused problems for positron researchers in their studies of complicated defective systems. In order to solve this problem, we aim to take a semiconductor material, for example, to achieve a credible average lifetime of single crystal silicon under plastic deformation at different temperatures using positron life time spectroscopy. By establishing reasonable positron trapping models with defective correlations and sorting out four lifetime components with multiple parameters, as well as their respective intensities, information is obtained on the positron trapping centers, such as the positron trapping rates of defects, the density of the dislocation lines and correlation between the dislocation lines, and the vacancy defects, by fitting with the average lifetime with the aid of Matlab software. These results give strong grounds for the existence of dislocation-vacancy correlation in plastically deformed silicon, and lay a theoretical foundation for the analysis of positron lifetime spectra when the positron trapping model involves dislocation-related defects.
Controversies in the Management of the First Time Shoulder Dislocation
Avila Lafuente, José Luis; Moros Marco, Santos; García Pequerul, José Manuel
2017-01-01
Background: Traditionally, initial management of first anterior shoulder dislocations consists of reduction of the glenohumeral joint followed by a period of immobilization and subsequent physical therapy to recover shoulder range of motion and strength. This traditional approach in management is now controversial due to the high rate of recurrence. The aim of this paper is to review and discuss the literature about the global management of patients presenting with first-time traumatic anterior glenohumeral dislocation, analyzing the factors that affect shoulder instability after the first episode of dislocation. Methods: Scientific publications about the management of first-time shoulder dislocations are reviewed. Pubmed is used for that and no limit in the year of publication are stablished. These papers and their conclusions are discussed. Results: Younger patients, patient´s activities and the kind of injury are the most important factors related to the shoulder instability after a first time traumatic dislocation. Authors that recommend surgical treatment after the first episode of dislocation argue that the possibilities of recurrence are high and therefore surgery should be performed before its occurrence. Other authors, however, argue that surgical treatment is demanding, and keep in mind that complications, such as recurrence, stiffness and pain after surgery, are still present. Conclusion: Currently, there is still no consensus in the literature with regard to the management of first episode of shoulder dislocation. It is necessary to analyze carefully every individual case to manage them more or less aggressive to obtain the best result in our practice. PMID:29430264
K-wire and tension band wire fixation in treating sternoclavicular joint dislocation.
Chen, Qing-yu; Cheng, Shao-wen; Wang, Wei; Lin, Zhong-qin; Zhang, Wei; Kou, Dong-quan; Shen, Yue; Ying, Xiao-zhou; Cheng, Xiao-jie; Lv, Chuan-zhu; Peng, Lei
2011-02-01
To evaluate the feasibility and therapeutic effect of treating sternoclavicular joint dislocation by K-wire and tension band wire fixation, and to improve the safety and stability of this technique. This study consisted of 9 cases, 6 males and 3 females with the mean age of 25 years (range, 9-62 years). The causes were traffic accident in 7 cases, falling in 1 case and fight in 1 case. The duration from injury to operation was 2 hours to 7 days. There were 5 left dislocations and 4 right dislocations; 8 anterior dislocations and 1 posterior dislocation, including one combined with left scapular fracture and one with left olecranon fracture. Open reduction and internal fixation using K-wires and tension band wires were performed to treat dislocations. All patients were followed up for 6 to 24 months, 10 months on average. According to Rockwood's rating scale on postoperative sternoclavicular joint, 8 cases achieved excellent outcomes with an average score of 13.88, and the rest case achieved a good outcome with the score of 12. Anatomical reduction was obtained in all cases. There were no such postoperative complications as severe infection, injury to blood vessel and nerve, failure of fixation, etc. Patients were all satisfied with the anatomical reduction and functional recovery. The technique of K-wire and tension band wire fixation is safe, simple, effective, less invasive and has been successfully used in orthopedic surgery. It is effective in treating sternoclavicular joint dislocation though it has some disadvantages.
Nagy, Mathias Thomas; Hla, Sann Minn; Keys, Graham Watson
2013-01-01
Streptococcus bovis is rare cause of late infections after total knee replacement (TKR). This report presents a case of confirmed late septic arthritis following TKR caused by S bovis that was further complicated with infective endocarditis resulting in aortic valve insufficiency in an immunecompetent patient. As an association between S bovis and gastrointestinal malignancies is suggested, a workup for such malignancies was performed that revealed non-malignant ulcers in patient's ascending colon. The patient is currently recovering from his aortic valve replacement surgery and is scheduled to have annual colonoscopies. His knee joint has improved; however, he developed constant pain because of underlying chronic infection in the affected joint and has difficulties mobilising. Therefore, a revision TKR is considered but postponed until he fully recovers from his heart valve surgery. PMID:23744853
Patellofemoral anatomy and biomechanics: current concepts
ZAFFAGNINI, STEFANO; DEJOUR, DAVID; GRASSI, ALBERTO; BONANZINGA, TOMMASO; MUCCIOLI, GIULIO MARIA MARCHEGGIANI; COLLE, FRANCESCA; RAGGI, FEDERICO; BENZI, ANDREA; MARCACCI, MAURILIO
2013-01-01
The patellofemoral joint, due to its particular bone anatomy and the numerous capsuloligamentous structures and muscles that act dynamically on the patella, is considered one of the most complex joints in the human body from the biomechanical point of view. The medial patellofemoral ligament (MPFL) has been demonstrated to contribute 60% of the force that opposes lateral displacement of the patella, and MPFL injury results in an approximately 50% reduction in the force needed to dislocate the patella laterally with the knee extended. For this reason, recent years have seen a growing interest in the study of this important anatomical structure, whose aponeurotic nature has thus been demonstrated. The MPFL acts as a restraint during motion, playing an active role under conditions of laterally applied stress, but an only marginal role during natural knee flexion. However, it remains extremely difficult to clearly define the anatomy of the MPFL and its relationships with other anatomical structures. PMID:25606512
Variation in the cost of care for primary total knee arthroplasties.
Haas, Derek A; Kaplan, Robert S
2017-03-01
The study examined the cost variation across 29 high-volume US hospitals and their affiliated orthopaedic surgeons for delivering a primary total knee arthroplasty without major complicating conditions. The hospitals had similar patient demographics, and more than 80% of them had statistically-similar Medicare risk-adjusted readmission and complication rates. Hospital and physician personnel costs were calculated using time-driven activity-based costing. Consumable supply costs, such as the prosthetic implant, were calculated using purchase prices, and postacute care costs were measured using either internal costs or external claims as reported by each hospital. Despite having similar patient demographics and readmission and complication rates, the average cost of care for total knee arthroplasty across the hospitals varied by a factor of about 2 to 1. Even after adjusting for differences in internal labor cost rates, the hospital at the 90th percentile of cost spent about twice as much as the one at the 10th percentile of cost. The large variation in costs among sites suggests major and multiple opportunities to transfer knowledge about process and productivity improvements that lower costs while simultaneously maintaining or improving outcomes.
Manubriosternal dislocation with spinal fracture: A rare cause for delayed haemothorax.
Kothari, Manish; Saini, Pramod; Shethna, Sunny; Dalvie, Samir
2015-01-01
Type 2 manubriosternal dislocations with concomitant spinal fracture are rare and may be associated with thoracic visceral injuries. The complication of delayed haemothorax has not been reported yet. We report a case of a young male who suffered manubriosternal dislocation with chance type thoracic spine fracture due to fall of a tree branch over his back. The haemothorax presented late on day three. The possible injury mechanism is discussed along with review of literature. We conclude that a lateral chest radiograph is indicated in spinal fracture patients complaining of midsternal pain. Computerized axial tomography scan of chest with contrast is indicated to rule out visceral injuries and a chest radiograph should be repeated before the patient is discharged to look for delayed haemothorax.
Traumatic dislocation of the S1 polyaxial pedicle screw head: a case report
Du Plessis, Pieter N. B.; Lau, Bernard P. H.
2017-01-01
Polyaxial screw head dislocation in the absence of a manufacture defect is extremely rare and represents a biomechanical overload of the screw, leading to early failure. A 58-year-old gentleman underwent instrumented fusion using polyaxial pedicle screws-titanium rod construct with interbody cage for spondylolytic spondylolisthesis at the L5/S1 level. He attempted to bend forward ten days after the surgery which resulted in a dislocation of the right S1 polyaxial screw head from the screw shank with recurrence of symptoms. He underwent revision surgery uneventfully. This case highlights the need to pay particular attention to the strength of fixation and the amount of release to avoid such a complication. PMID:28435927
Can, Ata; Erdogan, Fahri; Erdogan, Ayse Ovul
2017-09-01
Tibiofemoral instability is a common complication after total knee arthroplasty (TKA), accounting for up to 22% of all revision procedures. Instability is the second most common cause of revision in the first 5 years after primary TKA. In this study, 13 knees with tibiofemoral instability after TKA were identified among 693 consecutive primary TKA procedures. Patient demographics, body mass index, clinical symptoms, previous deformity, previous knee surgery, complications, interval between index TKA and first tibiofemoral instability, causes of instability, and interval between index TKA and revision TKA were retrospectively reviewed. Clinical outcomes were assessed with the Lysholm Knee Scoring Scale. All patients were women, and mean body mass index was 37.7 kg/m 2 (range, 27.2-52.6 kg/m 2 ). Mean interval between index TKA and first tibiofemoral instability was 23.4 months (range, 9-45 months), and mean interval between index TKA and revision TKA was 25.6 months (range, 14-48 months). All patients had posterior cruciate ligament-retaining implants. Of the 13 knees, 11 had flexion instability and 2 had global instability. In all patients, instability was caused by incompetence of the posterior cruciate ligament; additionally, 1 patient had undersized and malpositioned implants. In 4 knees, the polyethylene insert was broken as well. All patients underwent revision TKA. Lysholm Knee Scoring Scale score had improved from a mean of 35.8 (range, 30-46) to a mean of 68.3 (range, 66-76). All patients included in this study were female and obese. The main cause of instability was secondary posterior cruciate ligament rupture and incompetence. The use of posterior-stabilized implants for primary TKA may prevent secondary instability in obese patients. [Orthopedics. 2017; 40(5):e812-e819.]. Copyright 2017, SLACK Incorporated.
Revision Knee Arthroplasty in Patients with Inherited Bleeding Disorders: A Single-Center Experience
Kotela, Andrzej; Wilk-Frańczuk, Magdalena; Żbikowski, Piotr; Łęgosz, Paweł; Ambroziak, Paweł; Kotela, Ireneusz
2017-01-01
Background The results of total knee arthroplasty (TKA) in patients with inherited bleeding disorders (IBDs) are poorer when compared with those in the general population, with a notably higher risk of complications and higher revision rates. Thus, revision procedures are becoming a growing concern in this group of patients. The aim of this study was to evaluate the results of revision TKA in patients with IBD. Material/Methods A retrospective cohort study with longitudinal assessment of hemophilia patients scheduled for revision TKA between January 2010 and September 2015 was performed. The clinical status of the patients was assessed based on the Knee Society Score, and the Numeric Rating Scale was used to assess knee pain severity and patient satisfaction with the surgery. Radiological examination, post-operative complications, and reinterventions were recorded and analyzed. Results Very good results were obtained in all patients treated for aseptic loosening of the implant. However, inferior results were found in cases with infection. All patients operated on for aseptic loosening required only single-stage TKA, whereas patients with infection underwent multiple interventions. Complications were observed only in cases with infection. Conclusions Our study clearly outlined the differences in results based on failure mode, with far inferior results obtained in cases with infection. Given the lack of data in this area as well as the high specificity of this population, further high-quality studies are needed. PMID:28068306
Xu, B Y; Ji, B C; Guo, W T; Mu, W B; Cao, L
2017-06-01
Objective: To evaluate the influence of patellofemoral joint degeneration and pre-operative pain location on the outcome of medial Oxford unicompartmental knee arthroplasty (UKA). Methods: A total of 58 patients (58 knees) with medial Oxford UKA had been performed for medial osteoarthritis from March 2013 to July 2014 in Department of Orthopaedic Surgery at First Teaching Hospital of Xinjiang Medical University were retrospective reviewed. There were 24 males and 34 females, the age from 43 to 87 years with the mean age was 68.5 years. The mean body mass index was 25.2 kg/m(2) ranging from 19.7 to 31.5 kg/m(2). Patients were divided into anterior-medial pain group (35 knees), anterior knee pain group (17 knees) and general knee pain group (6 knees) according to pre-operative pain location. Pre-operative radiological statuses of the patellefemoral joint were defined by Ahlback system and divided into patellofemoral joint degeneration group (16 knees) and normal group (42 knees). Patients were also divided into medial patellofemoral degeneration group (20 knees), lateral patellofemoral degeneration group (12 knees) and normal group (26 knees) according to Altman scoring system. Outerbridge system was used intraoperatively and the patients were divided into patellofemoral joint degeneration group (21 knees) and normal group (37 knees). Pre- and post-operative outcomes were evaluated with Oxford Knee Score (OKS), Western Ontario and MacMaster (WOMAC) and patellofemoral score system of Lonner. T test and ANOVA were used to analyze the data. Results: The average duration of follow-up was 33 months (from 26 to 42 months). There were no patients had complications of infection, deep vein thrombosis, dislocation or loosing at the last follow-up. Compared to pre-operation, OKS (18.9±3.5 vs . 38.9±4.7, 19.3±4.2 vs . 39.6±4.6, 18.1±3.2 vs . 38.1±3.7)( t =5.64 to 7.08, all P <0.01) and WOMAC (10.9±2.3 vs .53.2±4.5, 10.4±2.1 vs .54.6±3.4, 11.7±1.8 vs .52.8±3.7)( t =14.50 to 19.16, all P <0.01) decreased, and the Lonner score (88.9±3.4 vs .38.6±2.8, 87.5±4.1 vs .38.2±2.3, 88.2±3.2 vs . 37.6±3.5)( t =-19.78 to -18.16, all P <0.01) increased significantly in anterior-medial pain group, anterior knee pain group and general knee pain group. According to Ahlback scoring system, compared to pre-operation, OKS (18.3±2.4 vs . 38.7±4.4, 19.6±1.8 vs . 38.4±3.1)( t =7.05, 9.08, both P <0.01) and WOMAC (10.6 ±2.6 vs .53.2±4.5, 12.1±1.4 vs .52.4±3.3)( t =14.21, 19.52, both P <0.01) decreased, the Lonner score (88.1±3.1 vs .38.3±3.3, 86.9±2.6 vs .39.1±2.4)( t =-18.90, -23.40, both P <0.01) increased significantly in patellofemoral joint degeneration group and normal group, the outcomes were the same according to Altman and Outerbridge scoring system. There was no significant difference between patellofemoral joint degeneration group and normal group based on Ahlback grading system. According to Altman classification, compared to normal group, there was no statistically differences in OKS, WOMAC and Lonner scoring system between patients with degeneration in the medial patellofemoral joint group, OKS and WOMAC increased (20.2±1.4 vs .18.2±2.7, 12.5±1.7 vs .10.5±2.5) ( t =-4.30, P =0.03; t =-4.80, P =0.02), the Lonner score decreased (84.3±2.8 vs .87.4±3.2) ( t =-6.20, P =0.01) in lateral patellofemoral degeneration group. According to Outerbridge scoring system, there were no statistically differences in patients in patellofemoral joint degeneration group and normal group. Conclusions: There is a good evidence that neither mild to moderate degree of patellofemoral joint degeneration nor pre-operative pain location will compromise the short-term outcome of medial Oxford UKA, and should not be considered as contraindications. The situation is less clear for lateral patellofemoral degeneration, and more cautious option is advised.
Chronic Quadriceps Tendon Rupture After Total Knee Arthroplasty Augmented With Synthetic Mesh.
Ormaza, Amaia; Moreta, Jesús; Mosquera, Javier; de Ugarte, Oskar Sáez; Mozos, José Luis Martinez-de Los
2017-01-01
Tear of the quadriceps tendon after revision or primary total knee arthroplasty is a rare complication, but when it occurs, this injury has serious functional consequences. In complete tears, the outcome of direct repair is unpredictable, and several authors recommend that the suture should be reinforced. Several techniques have been described, including the use of autografts, allografts, and synthetic mesh. The goal of this study was to assess the outcomes of a reconstruction technique augmented with synthetic mesh. A retrospective study was performed involving 3 patients who had chronic partial quadriceps tendon tear after total knee revision. In 2 cases, proximal quadriceps release was performed. When conservative management failed, surgical reconstruction with suture reinforced with synthetic mesh was attempted. The knee was immobilized in full extension for 6 weeks after the surgical procedure. A minimum follow-up of 12 months was required to assess results. All reconstructions showed clinical success at a mean follow-up of 19 months. Mean Knee Society Score improved from 55.7 to 87.3, with average postoperative extensor lag of 3.3° (range, 0°-10°). The mean visual analog scale pain score was 2.3 (range, 0-4). No complications were reported. Synthetic mesh has previously been shown to be an effective treatment for patellar tendon repairs after total knee replacement, but there have been few articles on quadriceps rupture. Surgical reconstruction with synthetic mesh is a viable option that provides good functional outcomes in chronic quadriceps tendon rupture after total knee arthroplasty. [Orthopedics. 2017; 40(1):38-42.]. Copyright 2016, SLACK Incorporated.
Zan, Pengfei; Wu, Zhong; Yu, Xiao; Fan, Lin; Xu, Tianyang; Li, Guodong
2016-03-01
During total knee arthroplasty (TKA), surgical exposure requires mobilization technique of the patella. With this trial, we intended to investigate the effect of patella eversion on clinical outcome measures in simultaneous bilateral TKA. We prospectively enrolled 44 patients (88 knees) from April 2008 to June 20l4.One knee was operated with patella eversion (group A) and the other with patella lateral retraction (group B) randomly. Follow-up results, including the operation time, complications, and the time of achieving straight leg raise (SLR) and 90° knee flexion, were recorded. The data of range of motion (ROM) and Visual Analogue Scale score were collected separately at 7 days, 3 months, 6 months, and 1 year postoperatively. The time of achieving SLR was 2.7 ± 0.8 days in group A and 2.1 ± 0.7 DAYS in group B, which were significantly different (P = .032). Significant difference was found on active and passive ROM during the follow-up times between groups A and B, except the passive ROM at 6 months postoperatively. No significant difference was found on operation time, complications, patella baja or tilt, time of achieving 90°knee flexion, and Visual Analogue Scale score during the follow-up times. Patellar eversion was adverse to the early knee function recovery after TKA; it would delay the time of achieving SLR and decrease the passive and active ROM. In addition, more carefully and scientifically designed randomized controlled trials are still required to further prove the claim. Copyright © 2016 Elsevier Inc. All rights reserved.
Jawed, Akram; Kumar, Vijay; Malhotra, R; Yadav, C S; Bhan, S
2012-06-01
Since the introduction of mobile bearing total knee designs nearly 30 years back, many studies have been done to evaluate its long-term result. Comparison with fixed bearing designs has been done in the past, but the studies were confounded by variables such as disease, surgeon, bone quality, pain tolerance, etc. We attempt to eliminate these variables in this study. A total of 50 patients who had bilateral arthritis of the knee with similar deformity and pre-operative range of motion on both sides agreed to have one knee replaced with mobile bearing total knee design (PFC-RP) and the other with a fixed bearing design (PFC Sigma) were prospectively evaluated. Comparative analysis of both the designs was done at a mean follow-up of 40 months, minimizing patient, surgeon and observer related bias. Clinical and radiographic outcome, survival and complication rates were compared. At a mean follow-up of 40 months (range 36-47 months), no benefit of mobile bearing (PFC-RP) over fixed bearing design (PFC Sigma) could be demonstrated with respect to Knee Society scores, pain scores, range of flexion, subject preference or patello-femoral complication rates. Radiographs showed no difference in prosthetic alignment. No patient required a revision surgery till last follow-up. Our study demonstrated no advantage of the mobile-bearing arthroplasty over fixed bearing arthroplasty with regard to clinical results at short-term follow-up. However, longer follow-up is necessary to confirm whether these results are sustained.
Kim, Seong Hwan; Lim, Jung-Won; Ko, Young-Bong; Song, Min-Gu; Lee, Han-Jun
2016-11-01
The purpose of this study was to compare the midterm outcomes between fixed and mobile ultra-congruent (UC) bearings in total knee arthroplasty (TKA). This is a retrospective matched-pairs case-control study of patients who underwent primary navigation-assisted TKA with a minimum 5-year follow-up. A total of 182 cases involved the fixed UC bearing system as Group 1 and 101 cases involved mobile UC bearing system group as Group 2. After 1:1 matching, 73 knees in each group were enrolled. Clinical and radiographic outcomes were evaluated. The overall survival was 143 of 146 cases (97.9 %) at final follow-up, and 72 of 73 cases (96.3 %) in Group 1 and 71 of 73 cases (95.8 %) in Group 2 at final follow-up based on an endpoint of revision surgery. The reasons of revision TKA were periprosthetic fracture in Group 1, infection and bearing dislocation in Group 2. There was no statistical difference in Hospital for Special Surgery (HSS) scores, Knee Society Scores (KSS), WOMAC index score evaluations between groups. This study demonstrated that the fixed-bearing UC prosthesis could provide satisfactory performance compared with that of the mobile-bearing UC prosthesis with minimum 5-year follow-up. The fixed-bearing UC prosthesis could be considered in navigation-assisted TKA with theoretical advantages of UC design. IV.
Risk Factors for Migration, Fracture, and Dislocation of Pancreatic Stents
Kawaguchi, Yoshiaki; Lin, Jung-Chun; Kawashima, Yohei; Maruno, Atsuko; Ito, Hiroyuki; Ogawa, Masami; Mine, Tetsuya
2015-01-01
Aim. To analyze the risk factors for pancreatic stent migration, dislocation, and fracture in chronic pancreatitis patients with pancreatic strictures. Materials and Methods. Endoscopic stent placements (total 386 times) were performed in 99 chronic pancreatitis patients with pancreatic duct stenosis at our institution between April 2006 and June 2014. We retrospectively examined the frequency of stent migration, dislocation, and fracture and analyzed the patient factors and stent factors. We also investigated the retrieval methods for migrated and fractured stents and their success rates. Results. The frequencies of stent migration, dislocation, and fracture were 1.5% (5/396), 0.8% (3/396), and 1.2% (4/396), respectively. No significant differences in the rates of migration, dislocation, or fracture were noted on the patient factors (etiology, cases undergoing endoscopic pancreatic sphincterotomy, location of pancreatic duct stenosis, existence of pancreatic stone, and approach from the main or minor papilla) and stent factors (duration of stent placement, numbers of stent placements, stent shape, diameter, and length). Stent retrieval was successful in all cases of migration. In cases of fractured stents, retrieval was successful in 2 of 4 cases. Conclusion. Stent migration, fracture, and dislocation are relatively rare, but possible complications. A good understanding of retrieval techniques is necessary. PMID:25945085
DOE Office of Scientific and Technical Information (OSTI.GOV)
France, R. M.; Geisz, J. F.; Steiner, M. A.
Surface crosshatch roughness typically develops during the growth of lattice-mismatched compositionally graded buffers and can limit misfit dislocation glide. In this study, the crosshatch roughness during growth of a compressive GaInP/GaAs graded buffer is reduced by increasing the phosphine partial pressure throughout the metamorphic growth. Changes in the average misfit dislocation length are qualitatively determined by characterizing the threading defect density and residual strain. The decrease of crosshatch roughness leads to an increase in the average misfit dislocation glide length, indicating that the surface roughness is limiting dislocation glide. Growth rate is also analyzed as a method to reduce surfacemore » crosshatch roughness and increase glide length, but has a more complicated relationship with glide kinetics. Using knowledge gained from these experiments, high quality inverted GaInAs 1 eV solar cells are grown on a GaInP compositionally graded buffer with reduced roughness and threading dislocation density. The open circuit voltage is only 0.38 V lower than the bandgap potential at a short circuit current density of 15 mA/cm{sup 2}, suggesting that there is very little loss due to the lattice mismatch.« less
Ram, Jagat; Gupta, Nishant; Chaudhary, Manish; Verma, Neelam
2013-01-01
Background: A new emerging complication of trans-scleral fixation of posterior chamber (PC) intraocular lens (IOL) with polypropylene suture is high rates of spontaneous dislocation of the IOL due to disintegration or breakage of suture. Materials: We report a new surgical technique of trans-scleral fixation of posterior chamber intraocular lens (SF PCIOL) with steel suture to eliminate the complication of dislocation of IOL fixed with polypropylene suture in one adult and a child. Results: We successfully achieved stable fixation and good centration of IOL after SF PCIOL with steel suture in these patient having inadequate posterior capsular support. Both eyes achieved best corrected visual acuity 20/40 at 18 months follow-up. Conclusions: Steel suture is a viable option for trans-scleral fixation of posterior chamber intraocular lens. PMID:23619504
Sun, Hao; Zhou, Lin; Li, Fengsheng; Duan, Jun
2017-02-01
Young active patients with medial knee osteoarthritis (OA) combined with varus leg alignment can be treated with high tibial osteotomy (HTO) to stop the progression of OA and avoid or postpone total knee arthroplasty (TKA). Closing-wedge osteotomy (CWO) and opening-wedge osteotomy (OWO) are the most commonly used osteotomy techniques. The purpose of this study was to compare the clinical and radiologic outcomes and complications between OWO and CWO. We retrospectively evaluated 23 studies including 17 clinical trials from published databases from their inception to May 2015. We evaluated the clinical outcomes including operation time, visual analog scale (VAS), maximal flexion, and hospital for special surgery knee (HSS) score. The radiologic outcomes included patellar height measured by posterior tibial slope angle, hip-knee-ankle (HKA) angle, femorotibial (FT) axis, and limb length. Complications recorded included the incidence of deep vein thrombosis (DVT), common peroneal nerve injury, opposite cortical fracture, etc. There were no differences in most of the clinical outcomes except the operation time. OWO increased the posterior slope angle and limb length, decreased the patellar height, and provided higher accuracy of correction. CWO led to a higher incidence of opposite cortical fracture. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Revision Proximal Interphalangeal Arthroplasty: An Outcome Analysis of 75 Consecutive Cases.
Wagner, Eric R; Luo, T David; Houdek, Matthew T; Kor, Daryl J; Moran, Steven L; Rizzo, Marco
2015-10-01
To examine the outcomes and complications associated with revision proximal interphalangeal (PIP) joint arthroplasty. An analysis of 75 consecutive revision PIP joint arthroplasties in 49 patients, performed between 1998 to 2012, was performed. The mean age at the time of surgery was 58 years. Thirty-two patients had a history of prior PIP joint trauma, and 18 patients had rheumatoid arthritis. There were 12 constrained (silicone) implants and 63 nonconstrained implants (34 pyrocarbon and 29 metal-plastic). Over the 14-year period, 19 (25%) fingers underwent a second revision surgery. Second revision surgeries were performed for infection, instability, flexion contracture, and heterotopic ossification. The 2-, 5-, and 10-year survival rates were 80%, 70%, and 70%, respectively, for patients requiring a second revision for PIP joint arthroplasty. Worse outcomes were seen with postoperative dislocations, pyrocarbon implants, and when bone grafting was required. Two operations were complicated by intraoperative fractures, but neither required stabilization. Sixteen patients undergoing revision surgery experienced a postoperative complication, including 2 infections, 1 postoperative fracture, 3 cases of heterotopic ossification, and 10 PIP joint dislocations. The volar approach and the use of a pyrocarbon implant was associated with increased rates of heterotopic ossification, whereas preoperative instability increased the rates of PIP joint dislocation following revision. At a mean of 5.3 years (range, 2-10 years) follow-up, 98% of patients had good pain relief but decreased PIP joint total arc of motion. Proximal interphalangeal joint arthroplasty in the revision setting represents a challenge for surgeons. Revision arthroplasty was associated with a 70% 5-year survival but with a high incidence of complications. Instability was associated with worse outcomes. In this series, silicone and metal-polyethylene implants had lower rates of implant failure and postoperative complications than ones made from pyrocarbon. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Comparison of the cable pin system with conventional open surgery for transverse patella fractures.
Mao, Ningfang; Liu, Deding; Ni, Haijian; Tang, Hao; Zhang, Qiulin
2013-07-01
The cable pin system is an effective device for fixation of transverse patella fractures. However, whether this device provides superior results using a minimally invasive technique instead of conventional open surgery using the K wire tension band method is unclear. We asked whether a minimally invasive technique would be associated with (1) increased operative time; (2) reduced postoperative pain; (3) faster recovery of ROM; (4) higher knee scores; and (5) reduced complications. Forty patients with displaced transverse fractures of the patella participated in this prospective, randomized, controlled trial. Twenty of these patients underwent a minimally invasive technique and the others had conventional open surgery using K wires. Some data for six of the 20 patients who underwent the minimally invasive technique were published in an earlier prospective, observational trial. At postoperative intervals of 1, 3, 6, 12, and 24 months, pain was measured by VAS scores, active flexion and extension of the knee were measured in degrees by goniometry, and knee function was evaluated using the Böstman clinical grading scale. Operative time was longer in the minimally invasive surgery group (54.3 ± 9.8 minutes versus 48.5 ± 6.1 minutes). Pain scores were better (lower) in the minimally invasive surgery group at 1 and 3 months but not at 6 months. Early flexion, ultimate flexion, and knee scores from 3 to 24 months, likewise, were better in the minimally invasive surgery group. Complications mostly related to symptomatic hardware were less common in the minimally invasive surgery group. The minimally invasive technique is superior to conventional open surgery using K wires in terms of less early postoperative pain, better mobility angles of the injured knee, higher functional score of the injured knee, and decreased incidence of complications. Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Autologous blood transfusion in total knee replacement surgery.
Sarkanović, Mirka Lukić; Gvozdenović, Ljiljana; Savić, Dragan; Ilić, Miroslav P; Jovanović, Gordana
2013-03-01
Total knee replacement (TKR) surgery is one of the most frequent and the most extensive procedures in orthopedic surgery, accompanied with some serious complications. Perioperative blood loss is one of the most serious losses, so it is vital to recognize and treat such losses properly. Autologous blood transfusion is the only true alternative for the allogeneic blood. The aim of this study was to to examine if autologous blood transfusion reduces usage of allogenic blood in total knee replacement surgery, as well as to examine possible effect of autologous blood transfusion on postoperative complications, recovery and hospital stay of patients after total knee replacement surgery. During the controlled, prospective, randomised study we compared two groups of patients (n = 112) with total prosthesis implanted in their knee. The group I consisted of the patients who received the transfusion of other people's (allogeneic) blood (n = 57) and the group II of the patients whose blood was collected postoperatively and then given them [their own (autologous) blood] (n = 55). The transfusion trigger for both groups was hemoglobin level of 85 g/L. In the group of patients whose blood was collected perioperatively only 9 (0.9%) of the patients received transfusion of allogeneic blood, as opposed to the control group in which 98.24% of the patients received the transfusion of allogeneic blood (p < or = 0.01). The patients whose blood was collected stayed in hospital for 6.18 days, while the patients of the control group stayed 7.67 days (p < 0.01). Autologous blood transfusion is a very effective method for reducing consumption of allogenic blood and thus, indirectly for reducing all complications related to allogenic blood transfusion. There is also a positive influence on postoperative recovery after total knee replacement surgery due to the reduction of hospital stay, and indirectly on the reduction of hospital costs.
Zhang, Chuan-Yi; Lin, Lie; Liang, Jun-Bo; Wang, Bin; Chen, Guo-Fu; Chen, Hai-Xiao
2016-11-25
To evaluate the therapeutic effect of a new type sternoclavicular hook plate fixation in treating unstable sternoclavicular joint dislocation and fracture. From June 2011 to December 2013, 32 patients with sternoclavicular joint dislocation and fracture were treated with a new type sternoclavicular hook plate fixation, including 24 males and 8 females with an average age of 42 years ranging from 25 to 76 years;12 patients were anterior dislocation, 5 pations were posterior dislocation, 10 patients were internal extremity of clavicle fracture and 5 patients were sternoclavicular joint dislocation combined with fracture. The anterior fracture dislocation of the sternoclavicular joint adopted standard sternoclavicular joint hook plate, and the posterior dislocation was at the distal end of the hook of the steel plate, that is, the front part of the handle of the breast was added with a nut and a gasket to prevent the re-dislocation after operation. The results were evaluated according to Rockwood score. No complication happened in all patients. X-ray and CT showed that the dislocation and fracture of the sternoclavicular joint was well reduced and the plate was on right position. All patients were followed up for 6 to 24 months with an average of 10 months. At 6 to 3 months after operation, the fracture was healing without re-dislocation of the sternoclavicular joint, the medial end of the clavicle anatomical structure were restored, functional satisfaction, in which 9 patients with the swelling around sternoclavicular joint, but no pain and other symptoms. The total Rockwood score was 12.78±1.43; the results were excellent in 24 cases, good in 8 cases. The use of the new type of locking hook plate for the treatment of unstable fracture of the sternoclavicular joint, internal fixation is reliable, high security, easy to operate, to provide a reliable method for the treatment of such trauma.
[Larsen syndrome: two reports of cases with spinal cord compromise].
Martín Fernández-Mayoralas, D; Fernández-Jaén, A; Muñoz-Jareño, N; Calleja-Pérez, B; San Antonio-Arce, V; Martínez-Boniche, H
Larsen syndrome is characterised by untreatable congenital dislocation of multiple body joints, along with marked foot deformities. These patients have a flattened face with a short nose, a broad depressed nasal bridge and a prominent forehead. In this clinical note our aim is to report two cases that coursed with spinal cord compromise. Case 1: an 18-month-old female with congenital dislocation of knees and hips. The patient had a flat face, sunken root of nose, and carp mouth. Magnetic resonance imaging of the spine showed severe cervical kyphosis secondary to malformation and hypoplasia of the cervical vertebral bodies and important compression of the spinal cord. Clinically, there were also signs of upper motor neuron syndrome, which was especially prominent in the lower limbs. Case 2: a 14-year-old male with a characteristic face and dislocation of the head of the radius. The patient presented amyotrophy of the muscles in the right hand and clinical signs of lower motor neuron syndrome due to neuronal damage secondary to spinal malformations. Larsen syndrome is an infrequent osteochondrodysplasia. Alteration of the spine is common and may give rise to spinal cord compression with varying clinical repercussions which require surgical treatment in the early years of the patient's life.
Poeran, Jashvant; Rasul, Rehana; Suzuki, Suzuko; Danninger, Thomas; Mazumdar, Madhu; Opperer, Mathias; Boettner, Friedrich
2014-01-01
Objective To determine the effectiveness and safety of perioperative tranexamic acid use in patients undergoing total hip or knee arthroplasty in the United States. Design Retrospective cohort study; multilevel multivariable logistic regression models measured the association between tranexamic acid use in the perioperative period and outcomes. Setting 510 US hospitals from the claims based Premier Perspective database for 2006-12. Participants 872 416 patients who had total hip or knee arthroplasty. Intervention Perioperative intravenous tranexamic acid use by dose categories (none, ≤1000 mg, 2000 mg, and ≥3000 mg). Main outcome measures Allogeneic or autologous transfusion, thromboembolic complications (pulmonary embolism, deep venous thrombosis), acute renal failure, and combined complications (thromboembolic complications, acute renal failure, cerebrovascular events, myocardial infarction, in-hospital mortality). Results While comparable regarding average age and comorbidity index, patients receiving tranexamic acid (versus those who did not) showed lower rates of allogeneic or autologous transfusion (7.7% v 20.1%), thromboembolic complications (0.6% v 0.8%), acute renal failure (1.2% v 1.6%), and combined complications (1.9% v 2.6%); all P<0.01. In the multilevel models, tranexamic acid dose categories (versus no tranexamic acid use) were associated with significantly (P<0.001) decreased odds for allogeneic or autologous blood transfusions (odds ratio 0.31 to 0.38 by dose category) and no significantly increased risk for complications: thromboembolic complications (odds ratio 0.85 to 1.02), acute renal failure (0.70 to 1.11), and combined complications (0.75 to 0.98). Conclusions Tranexamic acid was effective in reducing the need for blood transfusions while not increasing the risk of complications, including thromboembolic events and renal failure. Thus our data provide incremental evidence of the potential effectiveness and safety of tranexamic acid in patients requiring orthopedic surgery. PMID:25116268
Lizaur-Utrilla, Alejandro; Collados-Maestre, Isabel; Miralles-Muñoz, Francisco A; Lopez-Prats, Fernando A
2015-08-01
A prospective matched cohort study was performed to compare outcomes of total knee arthroplasties (TKA) between 29 patients with posttraumatic osteoarthritis (POA) after a fracture of tibial plateau and 58 patients underwent routine TKA. Mean follow-up was 6.7 years. There were no significant differences in KSS, WOMAC, SF12 scores or range of motion. In the control group there were no complications. In the posttraumatic group, complications occurred in 4 patients (13.7%) (P=0.010) including partial patellar tendon detachment, superficial infection, skin necrosis, and knee stiffness. Only this last patient required revision for manipulation under anesthesia. Also, there was a revision for tibial aseptic loosening in each group. TKA is an effective treatment for POA after tibial plateau fracture. We recommend the prior removal of hardware, as well as tibial tubercle osteotomy when necessary. Copyright © 2015 Elsevier Inc. All rights reserved.
Regional or general anesthesia for fast-track hip and knee replacement - what is the evidence?
Kehlet, Henrik; Aasvang, Eske Kvanner
2015-01-01
Regional anesthesia for knee and hip arthroplasty may have favorable outcome effects compared with general anesthesia by effectively blocking afferent input, providing initial postoperative analgesia, reducing endocrine metabolic responses, and providing sympathetic blockade with reduced bleeding and less risk of thromboembolic complications but with undesirable effects on lower limb motor and urinary bladder function. Old randomized studies supported the use of regional anesthesia with fewer postoperative pulmonary and thromboembolic complications, and this has been supported by recent large non-randomized epidemiological database cohort studies. In contrast, the data from newer randomized trials are conflicting, and recent studies using modern general anesthetic techniques may potentially support the use of general versus spinal anesthesia. In summary, the lack of properly designed large randomized controlled trials comparing modern general anesthesia and spinal anesthesia for knee and hip arthroplasty prevents final recommendations and calls for prospective detailed studies in this clinically important field. PMID:26918127
Extensor Mechanism Disruption after Total Knee Arthroplasty: A Case Series and Review of Literature.
Vaishya, Raju; Agarwal, Amit Kumar; Vijay, Vipul
2016-02-04
Extensor mechanism disruption following total knee arthroplasty (TKA) is a rare but devastating complication. These patients may require revision of the implants, but even then, it may not be possible to restore the normal function of the knee after the disruption. The patterns of extensor mechanism disruption can broadly be classified into three types: suprapatellar (quadriceps tendon rupture), transpatellar (patellar fracture), or infrapatellar (patellar tendon rupture). Infrapatellar tendon ruptures are the worst injuries, as they carry maximum morbidity and are challenging to manage. The disruption of the extensor mechanism may occur either intra-operatively or in the immediate postoperative period due to an injury. The treatment of extensor mechanism complications after TKA may include either nonsurgical management or surgical intervention in the form of primary repair or reconstruction with autogenous, allogeneic, or synthetic substitutes. We have provided an algorithm for the management of extensor mechanism disruption after TKA.
Zicaro, Juan Pablo; Yacuzzi, Carlos; Astoul Bonorino, Juan; Carbo, Lisandro; Costa-Paz, Matias
2017-12-01
This study evaluated the clinical and radiographic outcomes of a series of patients treated with an anatomic inlay resurfacing implant, with a minimum two-year follow-up. Fifteen patients underwent patellofemoral-resurfacing procedures using a HemiCAP Wave Patellofemoral Inlay Resurfacing implant from 2010 to 2013. Clinical outcomes included: Visual Analog Scale (VAS), Lysholm score, Knee Society Score (KSS), and evaluation of Kujala, and Hospital for Special Surgery Patellofemoral score (HSS-PF). The postoperative complications were analyzed. Nineteen knees were evaluated; the average follow-up was 35.2months. Fourteen were women, with an average age of 54years. The pre-operative/postoperative clinical results presented a significant improvement: VAS 8/2.5, Lysholm 31.9/85.8, KSS 39.8/82.5, Kujala 32.1/79.3 and Hospital for Special Surgery Patellofemoral score (HSS-PF) 15.9/90.6. A total of 87% of patients were either satisfied or very satisfied with the overall outcome. There were no radiographic signs of loosening. Seven postoperative complications were recorded: two presented ongoing knee pain, one postoperative stiffness, one patellar bounce due to maltracking, two ilio-tibial band syndrome, and one tibial anterior tuberosity osteotomy nonunion. Two patients underwent a total knee arthroplasty conversion and were considered a failure. None of these complications were implant related. Patellofemoral inlay resurfacing for isolated patellofemoral arthritis was an effective and safe procedure with high levels of patient satisfaction. No mechanical implant failure was seen at a minimum two-year follow-up. This implant design appeared to be an alternative to the traditional patellofemoral prostheses. Concomitant osteochondral lesions, patellofemoral dysplasia or patellar maltracking might be poor prognostic factors for this type of implant. Copyright © 2017 Elsevier B.V. All rights reserved.
Wang, Yong; Sun, Jun-Ying; Zha, Guo-Chun
2017-03-01
Anterior knee pain (AKP) is integral to the overall success of total knee arthroplasty (TKA) without patellar resurfacing. Numerous studies have evaluated various factors that may contribute to AKP, including patellofemoral design, surgical technique, characteristics of the patient, and degree of chondromalacia. This study aims to explore whether patients who received lateral retinacular release (LRR) plus circumpatellar electrocautery (CE) in TKA attain a low incidence of AKP and whether the LRR plus CE increases postoperative complications. Between February 2001 and February 2009, all patients undergoing TKA without patellar resurfacing and LRR plus CE were evaluated. In total, 286 TKAs in 259 (88.7%) patients were available for assessment, with a mean of 9.3 ± 2.5 years (range: 6-14 years) after the index TKA. The patients were evaluated with a VAS and the Kujala patellofemoral score (KPS) for AKP and the Knee Society's clinical scoring system (KSS) for the clinical function. Satisfaction and LRR-related complications were also assessed. The mean KPS and KSS improved from 45.2 ± 12.9 and 75.4 ± 26.8 points preoperatively to 82.8 ± 10.0 and 151.6 ± 17.3 points at the final follow-up ( p < 0.001), respectively. Subjectively, 5.6% (16 of 286) of patients suffered from AKP and 88.1% (252 of 286) were satisfied or very satisfied. Postoperative complications occurred in 15 (5.2%) patients, but these complications were mild and did not require reoperation. None of patients exhibited aseptic and septic prosthesis loosening and required revision surgery in the final follow-up. LRR plus CE appears to be a reasonable option in TKA without patellar resurfacing. It may achieve adequate mid-term results, with a low incidence of AKP and postoperative complications.The level of evidence of the study is therapeutic level IV. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Ren, J T; Xu, C; Wang, J S; Liu, X L
2017-10-01
Objective: To evaluate the effects of three-dimensional printing patient-specific instrumentation(PSI) versus conventional instrumentation(CI) in the total knee arthroplasty. Methods: According to "patient-specific" , "patient-matched" , "custom" , "Instrumentation" , "Guide Instrumentation" , "cutting blocks" , "total knee arthroplasty" , "total knee replacement" , "TKA" and "TKR" , the literature on PubMed, EMbase, Cochrane library, CBM and WanFang were searched. According to the inclusion and exclusion criteria, the high quality randomized control trial (RCT) studies about three-dimensional (3D) printing patient-specific instrumentation versus conventional instrumentation in the total knee arthroplasty were collected. The post-operative limb mechanical axis outlier, the position of the components outlier, post-operative knee function, operative time, post-operative blood transfusion and complications were analyzed by RevMan 5.3 software. Results: A total of 13 high quality RCT studies were included. The results of Meta-analysis show that there were no statistical differences in the post-operative limb mechanical axis outlier( Z =0.55, P =0.58, 95% CI: 0.78 to 1.56), femoral coronal component outlier( Z =0.38, P =0.71, 95% CI: 0.69 to 1.72), tibia coronal component outlier( Z =1.95, P =0.05, 95% CI: 1.00 to 3.38), femoral rotation angle outlier( Z =0.36, P =0.72, 95% CI: 0.49 to 1.64), post-operative knee function( Z =1.18, P =0.24, 95% CI : -0.66 to 2.63), post-operative blood transfusions( Z =0.74, P =0.46, 95% CI: -0.10 to 0.05) and complications( Z =0.18, P =0.86, 95% CI: -0.07 to 0.05) between the PSI group and the CI group. But there are statistical differences in the operation time( Z =2.66, P =0.01, 95% CI: -15.97 to -2.41)and tibia sagittal component outlier ( Z =3.69, P =0.00, 95% CI: 1.43 to 3.18)between the PSI group and the CI group. Conclusions: In the primary total knee arthroplasty the PSI is not superior over the CI for the knee without severe knee varus or valgus deformity or contracture deformity, without the deformity around the knee and without the knee bone loss and obesity. The use of PSI in the primary total knee arthroplasty are not recommend.
Woodmass, Jarret M; Sanders, Thomas L; Johnson, Nick R; Wu, Isabella T; Krych, Aaron J; Stuart, Michael J; Levy, Bruce A
2018-02-14
Injury to the posterolateral corner (PLC) of the knee can lead to both varus and rotational instability. Multiple PLC reconstruction techniques have been described, including one-tailed graft (fibula-based constructs) or two-tailed graft (combined fibula- and tibia-based constructs). The purpose of our study was to evaluate the clinical outcomes of anatomical two-tailed graft reconstruction of the PLC in the setting of multiligament knee injuries (MKLIs) with grade III varus instability. Patients were identified through a prospective MLKI database between 2004 and 2013. Patients who received fibular collateral ligament and PLC reconstructions using a two-tailed graft and had a minimum follow-up of 2 years were included. Patients were assessed for clinical laxity grade, range of motion, and functional outcomes using Lysholm and International Knee Documentation Committee (IKDC) scores. Twenty patients (16 male, 4 female) with a mean age of 30.7 (range: 16-52) and a mean follow-up of 52.2 months (range: 24-93 months) were included. Knee dislocation (KD) grades included: 4 KD-1, 10 KD 3-L, 5 KD-4, and 1 KD-5. No patients had isolated PLC injuries. Mean IKDC and Lysholm score were 73.1 ± 25.8 and 78 ± 26, respectively. Mean range of motion was -1.1 to 122.8. In full extension, two patients (10%) had grade 1 laxity to varus stress. In 30 degrees of knee flexion, five (25%) patients had grade 1 laxity, and two (10%) had grade 2 laxity. Anatomical two-tailed PLC reconstruction can reliably restore varus stability when performed on patients with MLKIs and type C posterolateral instability with hyperextension external rotation recurvatum deformity. Satisfactory functional outcome scores were achieved in the majority of patients. This study supports the use of an anatomical two-tailed PLC reconstruction in the multiligament injured knee. The level of evidence is IV, case series. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Ebraheim, Nabil A; Liu, Jiayong; Ramineni, Satheesh K; Liu, Xiaochen; Xie, Joe; Hartman, Ryan G; Goel, Vijay K
2009-11-01
Many investigators have conducted studies to determine the biomechanics, causes, complications and treatment of unilateral facet joint dislocation in the cervical spine. However, there is no quantitative data available on morphological changes in the intervertebral foramen of the cervical spine following unilateral facet joint dislocation. These data are important to understand the cause of neurological compromise following unilateral facet joint dislocation. Eight embalmed human cadaver cervical spine specimens ranging from level C1-T1 were used. The nerve roots of these specimens at C5-C6 level were marked by wrapping a 0.12mm diameter wire around them. Unilateral facet dislocation at C5-C6 level was simulated by serially sectioning the corresponding ligamentous structures. A CT scan of the specimens was obtained before and after the dislocation was simulated. A sagittal plane through the centre of the pedicle and facet joint was constructed and used for measurement. The height and area of the intervertebral foramen, the facet joint space, nerve root diameter and area, and vertebral alignment both before and after dislocation were evaluated. The intervertebral foramen area changed from 50.72+/-0.88mm(2) to 67.82+/-4.77mm(2) on the non-dislocated side and from 41.39+/-1.11mm(2) to 113.77+/-5.65mm(2) on the dislocated side. The foraminal heights changed from 9.02+/-0.30mm to 10.52+/-0.50mm on the non-dislocated side and 10.43+/-0.50mm to 17.04+/-0.96mm on the dislocated side. The facet space area in the sagittal plane changed from 6.80+/-0.80mm(2) to 40.02+/-1.40mm(2) on the non-dislocated side. The C-5 anterior displacement showed a great change from 0mm to 5.40+/-0.24mm on the non-dislocated side and from 0mm to 3.42+/-0.20mm on the dislocated side. Neither of the nerve roots on either side showed a significant change in size. The lack of change in nerve root area indicates that the associated nerve injury with unilateral facet joint dislocation is probably due to distraction rather than due to direct nerve root compression.
Dislocation gliding and cross-hatch morphology formation in AIII-BV epitaxial heterostructures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovalskiy, V. A., E-mail: kovalva@iptm.ru; Vergeles, P. S.; Eremenko, V. G.
2014-12-08
An approach for understanding the origin of cross-hatch pattern (CHP) on the surface of lattice mismatched GaMnAs/InGaAs samples grown on GaAs (001) substrates is developed. It is argued that the motion of threading dislocations in the (111) slip planes during the relaxation of InGaAs buffer layer is more complicated process and its features are similar to the ones of dislocation half-loops gliding in plastically deformed crystals. The heterostructures were characterized by atomic force microscopy and electron beam induced current (EBIC). Detailed EBIC experiments revealed contrast features, which cannot be accounted for by the electrical activity of misfit dislocations at themore » buffer/substrate interface. We attribute these features to specific extended defects (EDs) generated by moving threading dislocations in the partially relaxed InGaAs layers. We believe that the core topology, surface reconstruction, and elastic strains from these EDs accommodated in slip planes play an important role in the CHP formation. The study of such electrically active EDs will allow further understanding of degradation and changes in characteristics of quantum devices based on strained heterostructures.« less
[Injuries of the acromioclavicular joint].
Meeder, P J; Dannöhl, C
1988-07-01
The injuries of the acromio-clavicular joint require a differentiated diagnosis and treatment. The classification of the acromio-clavicular dislocations from grade I to grade III according to Tossy is proved. The diagnosis of a complete acromio-clavicular dislocation (Tossy III) is an indication for a surgical repair. Many and different methods are reported in the literature. 178 patients with a fresh acromio-clavicular dislocation (Typ Tossy II and III) were treated at the BG-Unfallklinik Tübingen from 1970 to 1987 by suturing the ligaments, inserting pins across the joint and tension wire bending. In old cases with Tossy III dislocation of the acromio-clavicular joint an oblique osteotomy combined with the reduction of the clavicle is recommended as a method of choice. The results of these procedures and there possible intra- and postoperative complications are reported. The incision along the clavicle quite often gives scar problems. Therefore the advantages of an arched incision across the acromio-clavicular joint is pointed out. Because of there biomechanical relationship fractures in the lateral third of the clavicle are similar to dislocations of the acromio-clavicular joint. The classification of these fractures according to Jäger, Buschle and Breitner allows a differentiated management of these lesions.
Bilateral vertebral artery lesion after dislocating cervical spine trauma. A case report.
Wirbel, R; Pistorius, G; Braun, C; Eichler, A; Mutschler, W
1996-06-01
This case report illustrates the problems associated with diagnosis and management of vertebral artery injuries resulting from dislocating cervical spine trauma. Treatment involved the principles of anterior stabilization of dislocating cervical spine fracture as well as the diagnostic procedures and therapeutic modalities appropriate for vertebral artery lesions. Because vertebral artery injuries with cervical spine trauma are rarely symptomatic, they can easily be overlooked. Bilateral or dominant vertebral artery occlusion, however, may cause fatal ischemic damage to the brain stem and cerebellum. Cervical spine dislocation was stabilized immediately after admission using internal fixation by ventral plate and corticocancellous bone graft. Immediate angiography was performed when brain stem neurologic dysfunction manifested 36 hours after surgery. The patient was treated with anticoagulation, osmotherapy, and controlled hypertension. A fatal outcome resulted in this case of dominant left vertebral artery occlusion. Necropsy even revealed bilateral vertebral artery damage at the level of the osseous lesion. The possibility of the complication of a vertebral artery lesion should be kept in mind when examining patients with cervical spine trauma, especially in patients with fracture-dislocation. Immediate identification by vertebral angiography, magnetic resonance imaging, or thin-slice computed tomography scan is necessary for optimal management of this injury.
Miyake, Takahito; Kanda, Akio; Morohashi, Itaru; Obayashi, Osamu; Mogami, Atsuhiko; Kaneko, Kazuo
2017-06-01
Bipolar hip arthroplasty is a good option for treating femoral neck fractures, although some contraindications have been indicated. We report a case of intraoperative dislocation of the trial bipolar cup into the pelvis during bipolar hip arthroplasty. A 74-year-old woman underwent bipolar hip arthroplasty for a femoral neck fracture (AO31-B2). She was placed in a lateral decubitus position, and a direct lateral approach was used. During intraoperative trial reduction, the trial bipolar cup became disengaged and dislocated into the anterior space of hip joint. Several attempts to retrieve it failed. The permanent femoral component was inserted, and the wound was closed. The patient was repositioned supine to allow an ilioinguinal approach, and the component was easily removed. She had an uneventful, good recovery. Several cases of intraoperative dislocation of the femoral trial head during total hip arthroplasty have been reported, this is the first report of dislocation of a bipolar trial cup. A previous report described difficulty retrieving a trial cup. We easily removed our trial cup using another approach. It is vital to plan systematically for this frustrating complication.
[Knee and shoulder arthroscopy. Positioning and thermal injuries].
Meyer, S; Lobenhoffer, P
2008-11-01
Intraoperative positioning injuries during shoulder- and knee arthroscopy are rare complications and affect mainly nerves and soft tissue. Although the majority of these complications are reversible, in some cases serious negative consequences for the patient persist. This article describes the frequency of several positioning injuries including their prevention and the appropriate treatment. The legal responsibilities are illustrated as well as the importance of an intense preoperative investigation of preexisting diseases and possible risk factors. Furthermore, a review of possible thermal injuries of the patient during arthroscopy caused by e.g. electrosurgical instruments or the cold light source, is given as well as prevention strategies.
Effects of Cementing on Ligament Balance During Total Knee Arthroplasty.
Chow, Jimmy; Wang, Kevin; Elson, Leah; Anderson, Christopher; Roche, Martin
2017-05-01
Complications related to joint imbalance may contribute to some of the most predominant modes of failure in total knee arthroplasty (TKA). These complications include instability, aseptic loosening, asymmetric component wear, and idiopathic pain. Fixation may represent a step that introduces unchecked variability into the procedure and may contribute to the incidence of joint imbalance-related complications. The ability to quantify in vivo loading in the medial and lateral compartments would allow for the ability to confirm balance after fixation and prior to wound closure. This retrospective study sought to capture any variability and imbalance associated with cementing technique. A total of 93 patients underwent sensor-assisted TKA. All patients were confirmed to have quantifiably balanced joints prior to cementation. After cementing and final component placement, the sensor was reinserted into the joint to capture any cementation-induced changes in loading. Imbalance was observed in 44% of patients after cementation. There was no difference in the proportion of imbalance due to surgeon experience (P=.456), cement type (P=.429), or knee system (P=.792). A majority of knees exhibited loading increase in the medial compartment. It was concluded that cementation technique contributes to a significant amount of balance-related variability at the fixation stage of the procedure. The use of the sensor in this study allowed for the correction of all instances of imbalance prior to closure. More objective methods of balance verification may be important for ensuring optimal surgical outcomes. [Orthopedics. 2017; 40(3):e455-e459.]. Copyright 2017, SLACK Incorporated.
Peng, Wei-xiong; Zhang, Zhi; Liang, Jie-hong
2008-04-01
To investigate the clinical value of T shape approach in the treatment of proximal tibial fractures. One handrend and thirteen patients of proximal tibial fractures were randomly divided into two groups. Group A: 62 cases underwent the traditional exposure approach. According to Schatzker classification,the cases of II to VI type was 25, 10, 16, 6, 5 respectively. Group B:51 cases underwent T shape approach ahead of knee joint, the cases of II to VI type was 21, 8, 13, 5, 4 respectively. All data were analyzed by SPSS 10.0 to compare operation time, blood loss, duration of hospitalization, healing time, the time of osseous union and complications after operation. Sixty patients in group A and 50 patients in group B were followed-up from 12 to 24 months. (1) Operation time:group B was longer than A (P < 0.01). (2) Mean blood loss and duration of hospitalization was the same. (3) Clinical healing time:group B was shorter. (4) Mean time of osseous union: 48 group B was shorter. Function of knee: group B was better than group A. (Complication: group B was less than group A. As compared with traditional exposure approach, T shape approach of knee joint had advantages of small scar, fewer complications, faster union of fracture and earlier recovery of joint function. The approach is valuable for the treatment of proximal tibial fractures.
Management of dislocated intraocular lenses with iris suture.
Faria, Mun Y; Ferreira, Nuno P; Canastro, Mario
2017-01-19
Subluxated or malpositioned intraocular lenses (IOLs) and inadequate capsular support is a challenge for every ophthalmic surgeon. Iris suture of an IOL seems to be an easy technique for the management of dislocated 3-piece IOL, allowing the IOL to be placed behind the iris, far from the trabecular meshwork and corneal endothelium. The purpose of this study is to assess the results of pars plana vitrectomy (PPV) and iris suture of dislocated 3-piece acrylic IOLs. In this retrospective, nonrandomized, interventional case consecutive study, of a total of 103 dislocated IOLs, 36 eyes were considered for analysis. All 36 eyes had subluxated or totally luxated 3-piece IOL and underwent iris suture at the Ophthalmology Department of Santa Maria Hospital-North Lisbon Hospital Center, Portugal, from January 2011 until November 2015. All patients underwent 3-port 23-G PPV. The optic zone of the dislocated IOL was placed anterior to the iris with the haptics behind, in the posterior chamber. Haptics were sutured to iris followed by placement of the optics behind iris plane. Postoperative measures included best-corrected visual acuity (BCVA), IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and development of macular edema. A total of 36 eyes of 36 patients were included. All underwent successful iris fixation of dislocated 3-piece IOL. Mean overall follow-up was 15.9 months (range 3-58 months). At presentation, 16 eyes (44.4%) had a luxated IOL and 20 eyes (55.6%) a subluxated IOL. As underlying cause, 17 eyes (47.2%) had a history of complicated cataract surgery, 5 eyes (13.9%) had a traumatic dislocation of the IOL, and 6 eyes (16.7%) had a previous vitreoretinal surgery. A total of 8 eyes (22.2%) had late spontaneous IOL dislocation after uneventful cataract surgery. The mean preoperative BCVA was 1.09 ± 0.70 logarithm of the minimal angle of resolution (logMAR) units and mean postoperative BCVA was 0.48 ± 0.58 of logMAR units. The mean visual acuity improvement was 4.08 ± 5.33 lines on the logMAR scale. In this study, every IOL was stable at the last follow-up. As late complications, macular edema occurred in 1 patient and retinal detachment occurred in 2 patients. There were no cases of endophthalmitis. Iris suture fixation of subluxated IOL is a good treatment option for eyes with dislocated IOLs, leading to long-term stability of the IOL. The advantage of this procedure is using the same IOL in a closed eye surgery. No astigmatic difference is expected as no large corneal incision is needed.
Nakayama, Hiroshi; Kambara, Syunichiro; Iseki, Tomoya; Kanto, Ryo; Kurosaka, Kenji; Yoshiya, Shinichi
2017-10-01
To compare the early postoperative outcomes and complications of double-bundle anterior cruciate ligament (ACL) reconstruction with and without remnant preservation. The study population comprised 125 consecutive knees that underwent double-bundle ACL reconstruction using hamstring autograft. Among the 125 knees, remnant preservation was indicated for 50 knees, while standard double-bundle reconstruction was performed in the remaining 75 knees. Postoperative evaluations included heel-height difference (HHD) at periodical follow-ups, number of knees requiring arthroscopic debridement due to problematic extension loss within six months, re-injury within one year, graft status upon second-look arthroscopy, and clinical examinations by Lysholm score and KT measurement at one year. All patients could be followed up for a minimum of one year after surgery. When the results obtained from both groups were compared, HHD values were significantly larger in the preservation group at three and six months, and the rate of knees requiring arthroscopic debridement was also higher in this group (12% versus 4.0%). Graft status on second-look arthroscopy was considered to be good for 92% of the knees in the preservation group versus 59% in the non-preservation group. Re-injury rates within one year were 2.0% in the preservation group and 5.3% in the non-preservation group. No significant differences in clinical examinations were found between the groups at one year. Remnant preservation in double-bundle hamstring autograft ACL reconstruction may enhance tissue healing; however, retention of the remnant with its full volume resulted in an increased incidence of postoperative problematic extension loss. Copyright © 2017 Elsevier B.V. All rights reserved.
Ultrasound-guided thrombin injection of genicular artery pseudoaneurysm.
Rachakonda, Aditya; Qato, Khalil; Khaddash, Tamim; Carroccio, Alfio; Pamoukian, Vicken; Giangola, Gary
2015-07-01
Pseudoaneurysm is a rare complication after arthroscopic procedures involving the knee. A 38-year-old man presented 1 month after right-knee arthroscopy with a 2-cm pulsating mass on the medial side of the right knee. Duplex ultrasound evaluation revealed 2.5 × 2.1-cm pseudoaneurysm just distal to the patella with arterialized flow communicating with the inferior medial genicular artery. Ultrasound-guided thrombin injection was performed in an office setting, and the resolution of active flow within the pseudoaneurysm was confirmed with duplex ultrasonography. Copyright © 2015 Elsevier Inc. All rights reserved.
Hip and knee replacement in osteogenesis imperfecta.
Papagelopoulos, P J; Morrey, B F
1993-04-01
Five total hip and three total knee arthroplasties were performed, from 1969 to 1990, in six patients who had osteogenesis imperfecta. The patients who had a hip arthroplasty were followed for a mean of seven years, and those who had a knee arthroplasty, for a mean of ten years. Postoperatively, all had relief of pain and were able to walk; one patient used a walker and two used a cane. The only postoperative complication was an intrapelvic protrusion of the acetabular component six years after a bipolar hip replacement.
Sciatic nerve block causing heel ulcer after total knee replacement in 36 patients.
Todkar, Manoj
2005-12-01
Femoral and sciatic nerve blocks are often used for postoperative analgesia following total knee replacement surgery. In this report, we focus on cases of heel ulcers which occurred following the implementation of peripheral nerve block in concert with knee replacement surgery. In some instances, heel ulcers have resulted in delayed rehabilitation and prolonged hospital stays in this group of patients, which makes this phenomenon a potential burden on the healthcare system. Pressure points in the foot should be protected after the implementation of nerve blocks to prevent pressure sores. An awareness of this unusual complication related to knee replacement surgery is necessary to prevent its occurrence and avoid delays in patient rehabilitation and recovery.
Periprosthetic fracture of the proximal tibia after lateral unicompartmental knee arthroplasty.
Kumar, Arun; Chambers, Iain; Wong, Paul
2008-06-01
We report a case of periprosthetic fracture of the proximal tibia after lateral unicompartmental knee arthroplasty following a trivial fall. At the time of surgery, the components were found to be loose; and there was a large uncontained tibial defect with bone loss and communition at the fracture site. The patient was treated by revision total knee arthroplasty and proximal structural tibial allograft, with a satisfactory result at 5-year follow up. Our case illustrates that a bone-conserving unicompartmental knee arthroplasty, if complicated by a periprosthetic fracture, can also present with a difficult surgical problem. Attention to preoperative planning and to availability of structural allograft for such difficult cases is recommended.
Tabatabaee, Reza M; Rasouli, Mohammad R; Maltenfort, Mitchell G; Fuino, Robert; Restrepo, Camilo; Oliashirazi, Ali
2018-04-01
Image-based and imageless computer-assisted total knee arthroplasty (CATKA) has become increasingly popular. This study aims to compare outcomes, including perioperative complications and transfusion rate, between CATKA and conventional total knee arthroplasty (TKA), as well as between image-based and imageless CATKA. Using the 9th revision of the International Classification of Diseases codes, we queried the Nationwide Inpatient Sample database from 2005 to 2011 to identify unilateral conventional TKA, image-based, and imageless CATKAs as well as in-hospital complications and transfusion rates. A total of 787,809 conventional TKAs and 13,246 CATKAs (1055 image-based and 12,191 imageless) were identified. The rate of CATKA increased 23.13% per year from 2005 to 2011. Transfusion rates in conventional TKA and CATKA cases were 11.73% and 8.20% respectively (P < .001) and 6.92% in image-based vs 8.27% in imageless (P = .023). Perioperative complications occurred in 4.50%, 3.47%, and 3.41% of cases after conventional, imageless, and imaged-based CATKAs, respectively. Using multivariate analysis, perioperative complications were significantly higher in conventional TKA compared to CATKA (odds ratio = 1.17, 95% confidence interval 1.03-1.33, P = .01). There was no significant difference between imageless and image-based CATKA (P = .34). Length of hospital stay and hospital charges were not significantly different between groups (P > .05). CATKA has low complication rates and may improve patient outcomes after TKA. CATKA, especially the image-based technique, may reduce in-hospital complications and transfusion without increasing hospital charges and length of hospital stay significantly. Large prospective studies with long follow-up are required to verify potential benefits of CATKA. Copyright © 2017 Elsevier Inc. All rights reserved.
2013-01-01
Background Conversion of a knee arthrodesis to a Total Knee Arthroplasty is an uncommon procedure. Revision Total Knee Arthroplasty in this setting presents the surgeon with a number of challenges including the management of the extensor mechanism and patella. Case presentation We describe a unique case of a 69 years old Caucasian man who underwent a revision Total Knee Arthroplasty using a tibial tubercle osteotomy after a previous conversion of a knee arthrodesis without patella resurfacing. Unfortunately 9 months following surgery a tibial tubercle pseudarthrosis and spontaneous patella fracture occurred. Both were managed with open reduction and internal fixation. At 30 months follow-up the tibial tubercle osteotomy had completely consolidated while the patella fracture was still evident but with no signs of further displacement. The patient was completely satisfied with the outcome and had a painless range of knee flexion between 0-95°. Conclusions We believe that patients undergoing this type of surgery require careful counseling regarding the risk of complications both during and after surgery despite strong evidence supporting improved functional outcomes. PMID:24195600
Li, Qiwei; Kadhim, Muayad; Zhang, Lijun; Cheng, Xiangjun; Zhao, Qun; Li, Lianyong
2014-12-01
Few reports are available describing knee changes in neglected developmental dysplasia of the hip (DDH). The purpose of this study was to assess the radiographic morphology of knee joints in adults with neglected DDH. Thirty-seven patients (35 females and two males) with neglected DDH were prospectively recruited with an average age of 32.6 years. Twenty-three patients had unilateral and 14 patients had bilateral neglected DDH. Thirty-seven healthy individuals were recruited to form a matched control group. Three groups of knee joints were examined: affected knees (on the same side of the neglected DDH), unaffected knees (contralateral to the neglected DDH in patients with unilateral involvement), and control knees. A series of radiographic parameters of the knee joint were measured in the coronal and sagittal plane, and they were compared between patients and normal controls. In the coronal plane, the affected knees had increased valgus angulation related to increased height of the medial femoral condyle, decreased height of the lateral femoral condyle and decreased lateral distal femoral angle compared to control knees. In the sagittal plane, both distal femoral and proximal tibial joints of the affected knees developed a decrease in posterior angles. Additionally, the unaffected knees also developed radiographic changes compared to control knees. Patients with neglected DDH may develop changes in both knee joints. These changes should be considered during surgery to the hip, femur and knee to prevent potential complications. Level 2. Copyright © 2014 Elsevier B.V. All rights reserved.
Triantafyllopoulos, Ioannis K; Lampropoulou-Adamidou, Kalliopi; Schizas, Nikitas P; Karadimas, Eleftherios V
2017-12-01
Most acromioclavicular (AC) joint injuries occur in men in their third decade of life during high-speed or high-impact body contact sports. The management of acute complete AC joint dislocation is surgical. Current surgical techniques include anatomic reconstruction of the main restraints of the AC joint and aim to improve functional outcomes and to reduce the complication rate. We present 10 cases of acute type V AC joint dislocation in professional athletes treated surgically with anatomic reconstruction of the coracoclavicular and AC ligaments and augmentation with the use of a synthetic polyester tape. The minimum follow-up of the patients was 2 years (mean, 48 months; range, 24-86 months). The postoperative functional outcome was assessed at 1 year and 2 years using the Constant-Murley, American Shoulder and Elbow Surgeons, and modified University of California-Los Angeles scoring systems. In all cases, the postoperative scores were significantly improved (P < .005 in all comparisons with the preoperative scores), and all patients returned to their preinjury high level of activity 6 months postoperatively. Radiographs at 1 month and 6 months revealed the maintenance of reduction. There were no complications. According to the results of our series of patients, demanding cases of acute AC joint dislocation Rockwood type V, in professional athletes, require anatomic fixation of both coracoclavicular and AC ligaments for return to sports as soon as possible and at the preinjury level of performance. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Zhou, Yu; Zhou, Zhenyu; Liu, Lifeng; Cao, Xuecheng
2018-03-21
Skeletal and soft tissue damage are often associated with unilateral facet dislocations, which undoubtedly lead to instability of the spine and further increase difficulties in cervical reduction. This type of irreducible facet dislocation is usually accompanied with potential catastrophic consequences including neurological deficit and severe disability. Therefore, a consistent and evidence-based treatment plan is imperative. The literature regarding the management of traumatic unilateral locked cervical facet dislocations was reviewed. Two patient cases (a 30-year-old Asian man and a 25-year-old Asian woman) who suffered irreducible cervical facet dislocations were presented. These two patients received surgical treatments including posterior reduction by poking facet joints, adjacent spinous process fixation by wire rope banding, anterior plate fixation, and intervertebral fusion after the failure of skull traction and closed reduction. At the postoperative 24-month follow-up, intervertebral fusion was achieved and our patients' neurological status improved based on the American Spinal Injury Association scale, compared with their preoperative status. Unilateral facet joint dislocations of subaxial cervical spine are difficult to reduce when complicated with posterior facet fractures or ligamentous injury. Magnetic resonance imaging can be beneficial for identifying ventral and dorsal compressive lesions, as well as ligamentous or capsule rupture. The combination of posterior reduction and anterior fixation with fusion has advantages in terms of clinical safety, ease of operation, and less iatrogenic damage.
[Clinical study on patellar replacement in total knee arthroplasty].
Bao, Liang; Gao, Zhihui; Shi, Xiaoqiang; Fang, Xiaomin; Jin, Qunhua
2013-01-01
To evaluate the influence of patellar replacement on total knee arthroplasty by comparing with non patellar replacement. Between September 2010 and November 2010, 63 patients (63 knees) with osteoarthritis who met the selection criteria and underwent total knee arthroplasty, were randomly divided into 2 groups: patellar replacement in 32 cases (replacement group), non patellar replacement in 31 cases (non patellar replacement group). There was no significant difference in gender, age, disease duration, osteoarthritis grading, the clinical and functional scores of American Knee Society Score (KSS), the patellar tilt angle, tibiofemoral angle, and patellar ligament ratio between 2 groups (P > 0.05), they were comparable. After 6 weeks, 3, 6, and 12 months of operation, clinical and imaging evaluation methods were used to assessment the effectiveness. Primary healing of incision was obtained in all patients of 2 groups. Deep venous thrombosis occurred in 6 cases of replacement group and in 8 cases of non patellar replacement group. All patients were followed up 12 months. The postoperative incidence of anterior knee pain in replacement group was significantly lower than that in non patellar replacement group (P < 0.05) at 3, 6, and 12 months after operation. No significant difference was found in the postoperative KSS clinical score between 2 groups at each time point (P > 0.05). The joint function score of the replacement group was significantly higher than that of the non patellar replacement group at the other time point (P < 0.05) except the score at 6 weeks and 3 months. Significant difference was found in the patella score between 2 groups at 12 months (P < 0.05), but no significant difference at the other time points (P > 0.05). X-ray film showed no patellar fracture and dislocation, or loosening and breakage of internal fixation. At 12 months after operation, the tibiofemoral angle, the patellar ligament ratio, and the patellar tilt angle showed no significant difference between 2 groups (P > 0.05). Patella replacement can improve knee function score and the patella score, and reduce the incidence of postoperative anterior knee pain.
Zhang, Chi; Cai, You-Zhi; Lin, Xiang-Jin
2016-05-01
A literature review of the first-, second- and third-generation autologous chondrocyte implantation (ACI) technique for the treatment of large-sized (>4 cm(2)) and full-thickness knee cartilage defects in young adults was conducted, examining the current literature on features, clinical scores, complications, magnetic resonance image (MRI) and histological outcomes, rehabilitation and cost-effectiveness. A literature review was carried out in the main medical databases to evaluate the several studies concerning ACI treatment of large-sized and full-thickness knee cartilage defects in young adults. ACI technique has been shown to relieve symptoms and improve functional assessment in large-sized (>4 cm(2)) and full-thickness knee articular cartilage defect of young adults in short- and medium-term follow-up. Besides, low level of evidence demonstrated its efficiency and durability at long-term follow-up after implantation. Furthermore, MRI and histological evaluations provided the evidence that graft can return back to the previous nearly normal cartilage via ACI techniques. Clinical outcomes tend to be similar in different ACI techniques, but with simplified procedure, low complication rate and better graft quality in the third-generation ACI technique. ACI based on the experience of cell-based therapy, with the high potential to regenerate hyaline-like tissue, represents clinical development in treatment of large-sized and full-thickness knee cartilage defects. IV.
Knee arthrodesis with modular nail after failed TKA due to infection.
Gallusser, Nicolas; Goetti, Patrick; Luyet, Anais; Borens, Olivier
2015-12-01
Knee arthrodesis is an established procedure for limb salvage after failed total knee arthroplasty (TKA) in cases of recurrent infection, soft tissue damage, reduced bone stock or with a deficient extensor mechanism. Walking with an arthrodesis is more efficient and less costly in terms of energy expenditure than above-knee amputation. Surgical options include an arthrodesis nail, external fixator or compression plate. We present our results of knee arthrodesis using the modular Wichita Fusion Nail(®) in patients after infected TKA. Fifteen patients with irretrievably failed TKA, due to infection, who underwent arthrodesis with the Wichita Fusion Nail(®) from 2004 to 2012 were retrospectively reviewed to assess fusion rate, time to fusion, complication rate, including new infections, and ambulatory status. Three patients were lost to follow-up. Mean follow-up was 33 months (6-132 months). At their most recent follow-up, all patients were walking with full weight bearing on a fused arthrodesis. Mean time to union was 9 months (3-29 months). Three patients necessitated a revision arthrodesis to achieve union after a mean of 5 months after the last procedure. Arthrodesis with the Wichita Fusion Nail(®) provides satisfactory results in patients with failure after infected TKA, with 75 % primary union rate and no new or persistent infection at last follow-up visit. Although burdened with a high complication rate, it represents an acceptable option for limb salvage in this particular pathology.
Kim, Young-Hoo; Yoon, Sung-Hwan; Kim, Jun-Shik
2009-02-01
Although the design features of the Medial Pivot fixed-bearing prosthesis reportedly improve kinematics compared with TKAs using fixed-bearings, clinical improvements have not been reported. We asked whether the clinical and radiographic outcomes, ranges of motion of the knee, patient satisfaction, and complication rates would be better in knees with a Medial Pivot fixed-bearing prosthesis than in those with a PFC Sigma mobile-bearing prosthesis. We compared the results of 92 patients who had a Medial Pivot fixed-bearing prosthesis implanted in one knee and a PFC Sigma mobile-bearing prosthesis implanted in the other. There were 85 women and seven men with a mean age of 69.5 years (range, 55-81 years). The minimum followup was 2 years (mean, 2.6 years; range, 2-3 years). The patients were assessed clinically and radiographically using the rating systems of the Hospital for Special Surgery and the Knee Society at 3 months, 1 year, and annually thereafter. Contrary to expectations, we found worse early clinical outcomes, smaller ranges of knee motion, less patient satisfaction, and a higher complication rate for the Medial Pivot fixed-bearing prosthesis than for the PFC Sigma mobile-bearing prosthesis. Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Acute Infection in Total Knee Arthroplasty: Diagnosis and Treatment
Martínez-Pastor, Juan Carlos; Maculé-Beneyto, Francisco; Suso-Vergara, Santiago
2013-01-01
Infection is one of the most serious complications after total knee arthroplasty (TKA). The current incidence of prosthetic knee infection is 1-3%, depending on the series. For treatment and control to be more cost effective, multidisciplinary groups made up of professionals from different specialities who can work together to eradicate these kinds of infections need to be assembled. About the microbiology, Staphylococcus aureus and coagulase-negative staphylococcus were among the most frequent microorganisms involved (74%). Anamnesis and clinical examination are of primary importance in order to determine whether the problem may point to a possible acute septic complication. The first diagnosis may then be supported by increased CRP and ESR levels. The surgical treatment for a chronic prosthetic knee infection has been perfectly defined and standardized, and consists in a two-stage implant revision process. In contrast, the treatment for acute prosthetic knee infection is currently under debate. Considering the different surgical techniques that already exist, surgical debridement with conservation of the prosthesis and polythene revision appears to be an attractive option for both surgeon and patient, as it is less aggressive than the two-stage revision process and has lower initial costs. The different results obtained from this technique, along with prognosis factors and conclusions to keep in mind when it is indicated for an acute prosthetic infection, whether post-operative or haematogenous, will be analysed by the authors. PMID:23919094
Torga-Spak, Roger; Gugala, Zbigniew; Lindsey, Ronald W
2006-03-01
We present a case report of a patient who had a transverse subtrochanteric femur fracture develop 2 months after uneventful placement of a long femorotibial intramedullary nail for knee arthrodesis. To date, diaphyseal fracture of a femur already stabilized with an intramedullary nail has not been reported. The possible etiology for this unusual complication is discussed.
Cameron, James I; McCauley, Julie C; Kermanshahi, Arash Y; Bugbee, William D
2015-06-01
Distal femoral varus osteotomy may be used to treat valgus knee malalignment or to protect a knee compartment in which cartilage restoration surgery (such as osteochondral or meniscus allografting) has been performed. Medial closing-wedge osteotomy has demonstrated good success in treatment of osteoarthritis in published series, but few studies have evaluated distal femoral lateral opening-wedge osteotomy in terms of correction of deformity, pain and function, and survivorship. (1) Does lateral opening-wedge osteotomy lead to accurate correction? (2) What pain and function levels do patients experience after lateral opening-wedge osteotomy? (3) What are the nonunion, complication, and reoperation rates after lateral opening-wedge osteotomy? Between 2000 and 2010, we performed 40 distal femoral osteotomies. Two knees (two patients) underwent a medial closing-wedge osteotomy and were excluded from the present study. Thirty-eight knees (97%) in 36 patients were lateral opening-wedge varus-producing osteotomies; of those, 31 knees (82%) in 30 patients had followup at a minimum of 2 years (mean, 5 years; SD, 2; range, 2-12 years) and comprised the study population. The indications for osteotomy included symptomatic lateral compartment arthritis with clinical valgus deformity or a cartilage or meniscal defect in the lateral compartment with clinical valgus alignment. The study population was stratified into two groups based on reason for osteotomy: patients with isolated symptomatic lateral compartment arthritis (arthritis group; 19 knees [61%]) and patients who underwent joint preservation procedures including osteochondral allograft transplantation or meniscal allograft transplantation (joint preservation group; 12 knees [39%]). Data collection from our institution's osteotomy database included patient demographics, lower extremity coronal alignment, and operative details. Pain and function were measured preoperatively and postoperatively using the International Knee Documentation Committee (IKDC) score. Time to radiographic union, complications, and reoperations were recorded. Twenty-one of 31 knees had postoperative radiographic data available for review. Of these, seven of 15 knees in the arthritis group and three of six knees in the joint preservation group were within the correction goal of ± 3° from neutral mechanical alignment. In the arthritis group, the mean IKDC total score improved from 47 (SD, 15) preoperatively to 67 (SD, 10) postoperatively. In the joint preservation group, the mean IKDC total score improved from 36 (SD, 12) preoperatively to 62 (SD, 18) postoperatively. One nonunion occurred in the arthritis group. No postoperative complications were experienced. Ten knees in the arthritis group and six knees in the joint preservation group had additional surgery after the osteotomy, consisting primarily of hardware removal, arthroscopy for cartilage-related conditions, or conversion to arthroplasty. Survivorship at 5 years, with conversion to arthroplasty as the endpoint, was 74% in the arthritis group and 92% in the joint preservation group. Lateral opening-wedge distal femoral osteotomy was less accurate in correction of valgus deformity than expected, but the procedure was associated with improved knee pain and function scores. Our clinical and radiographic results are comparable to published series evaluating medial closing-wedge distal femoral osteotomy. Achieving our desired correction of ± 3° from neutral alignment was clinically difficult. An improved method of preoperative templating and refinement of the intraoperative technique may improve this. Future studies with more patients and longer followup will provide clarity on this topic. Level IV, therapeutic study.
[Complications after refractive surgery abroad].
Terzi, E; Kern, T; Kohnen, T
2008-05-01
In this article a retrospective analysis of patients presenting at a German university following refractive surgery abroad is presented. A total of 20 cases of patients who had undergone treatment between 1998 and 2006 in China (1 case), Greece (1 case), Iran (1 case), Russia (2 cases), Switzerland (1 case), Slovakia (1 case), Spain (2 cases), South Africa (3 cases), Turkey (6 cases) and the USA (2 cases) were analyzed retrospectively. The following complications were observed: epithelial ingrowth into the interface with or without melting of the flap (6 cases), corneal ectasia (2 cases), dislocation of a phakic posterior chamber intraocular lens and prolapse into the anterior chamber with endothelial cell loss (1 case), secondary increase of intraocular pressure following implantation of a phakic intraocular lens (1 case), flap-related complications following laser-in-situ keratomileusis (LASIK) (2 cases), keratitis (1 case), dislocation of the complete flap (1 case), diffuse lamellar keratitis (DLK) grade IV (1 case), hyperopia as a consequence of radial keratotomy (1 case), and under correction/over correction and poor optical quality following laser epithelial keratomileusis (LASEK) and LASIK for high myopia (5 cases) with possible early corneal ectasia. There are four important problems arising from refractive surgery abroad, often referred to as "LASIK tourism": wrong indications, insufficient management of complications, lack of postoperative care and the health economic aspect.
Reverse total shoulder replacement for nonunion of a fracture of the proximal humerus.
Zafra, M; Uceda, P; Flores, M; Carpintero, P
2014-09-01
Patients with pain and loss of shoulder function due to nonunion of a fracture of the proximal third of the humerus may benefit from reverse total shoulder replacement. This paper reports a prospective, multicentre study, involving three hospitals and three surgeons, of 35 patients (28 women, seven men) with a mean age of 69 years (46 to 83) who underwent a reverse total shoulder replacement for the treatment of nonunion of a fracture of the proximal humerus. Using Checchia's classification, nine nonunions were type I, eight as type II, 12 as type III and six as type IV. The mean follow-up was 51 months (24 to 99). Post-operatively, the patients had a significant decrease in pain (p < 0.001), and a significant improvement in flexion, abduction, external rotation and Constant score (p < 0.001), but not in internal rotation. A total of nine complications were recorded in seven patients: six dislocations, one glenoid loosening in a patient who had previously suffered dislocation, one transitory paresis of the axillary nerve and one infection. Reverse total shoulder replacement may lead to a significant reduction in pain, improvement in function and a high degree of satisfaction. However, the rate of complications, particularly dislocation, was high. ©2014 The British Editorial Society of Bone & Joint Surgery.
Outcomes of dual mobility cups in a young Middle Eastern population and its influence on life style.
Assi, Chahine; El-Najjar, Elie; Samaha, Camille; Yammine, Kaissar
2017-03-01
Dual mobility cups (DMC) in total hip arthroplasty (THA) are becoming popular among orthopaedic surgeons. Substantial benefit of their use has been reported among high risk patients, particularly in reducing post-operative hip instability (dislocation). Many reports stated some concern when implanted in young and active people where complications such as polyethylene wear and mechanical loosening could potentially be higher. This Middle Eastern study analyses a retrospective series of THA for any aetiology other than infection, using DMC for the acetabular component in 75 patients (85 implants) less than 70 years old. No instability, intra-prosthetic dislocation or mechanical failure was reported during a mean follow-up of five years. The only major complication was a post-operative infection. The mean post- operative modified Harris hip score was 97.1 out of 100. All patients resumed their daily activities and all religious practicing patients were able to accomplish their prayer positions without pain. DMC is found to be an interesting option in reducing dislocation events in young patients. Those excellent short-term results would encourage surgeons to use DMC in an active and highly demanding population. Further research is necessary to confirm maintenance of such results at long term follow-up.
[Mid-term effectiveness of rotating hinge knee prosthesis for severe knee deformity].
Zeng, Min; Hu, Yihe; Xie, Jie; Li, Mingqing; Lin, Shaoru
2014-01-01
To evaluate the mid-term effectiveness of rotating hinge knee prosthesis for severe knee deformity. A retrospective analysis was made on the clinical data of 24 patients (24 knees) who received rotating hinge knee prosthesis for total knee arthroplasty between January 2003 and June 2011. There were 14 males and 10 females, aged from 60 to 81 years (mean, 70 years). The disease causes included osteoarthritis in 5 cases, rheumatoid arthritis in 7 cases, traumatic arthritis in 9 cases, and Charcot's arthropathy in 3 cases. The disease duration ranged from 5 to 25 years (mean, 14.5 years). Of them, 13 cases had flexion deformity, 7 cases had valgus deformity, and 16 cases had varus deformity. The operation time, the amount of bleeding between operation and drainage-tubes removal, hospitalization time, incision healing, and complications were recorded. The results were evaluated according to Knee Society Score (KSS), visual analogue scale (VAS), and the range of motion (ROM) of knee. Short-form 36 health survey scale (SF-36) was used to evaluate the life quality of patients. The position of prosthesis was observed through X-ray examination. The operation time ranged from 70 to 90 minutes (mean, 78 minutes). The amount of bleeding between operation and drainage-tubes removal ranged from 400 to 1 000 mL (mean, 650 mL). The hospitalization time ranged from 14 to 18 days (mean, 15.2 days). Patellar fracture occurred in 1 case (4.17%) during operation, swelling and effusion of incision in 1 case (4.17%), and periprosthetic infections in 2 cases (8.33%) after operation. All patients were followed up 2-10 years (mean, 5.5 years). The X-ray films showed no evidence of obvious radiolucent line, osteolysis, prosthesis subsidence, and limb alignment change. The results of KSS, VAS socres, and ROM of knee at 1 year postoperatively and last follow-up were significantly better than preoperative ones (P < 0.05), but no significant difference was found between at 1 year postoperatively and last follow-up (P > 0.05). The physiological function and body pain scores were significantly lower than the reference value of urban men over 60 years old from Sichuan province (t = 2.42, P = 0.02; t = 5.26, P = 0.00), but no significant difference was found in the other scores of the SF-36 when compared with the reference value (P > 0.05). The mid-term effectiveness of total knee arthroplasty using rotating hinge knee for severe knee prosthesis deformity is satisfactory. But complications of postoperative infection should be emphasized.
Experiment K-314: Fetal and neonatal rat bone and joint development following in Utero spaceflight
NASA Technical Reports Server (NTRS)
Sabelman, E. E.; Holton, E. M.; Arnaud, C. D.
1981-01-01
Infant rat limb specimens from Soviet and U.S. ground-based studies were examined by radiography, macrophotography, histologic sectioning and staining and scanning electron microscopy. A comparison was conducted between vivarium and flight-type diets suggesting that nutritional obesity may adversely affect pregnancy. Data were obtained on maturation of ossification centers, orientation of collagen fibers in bone, tendon and ligaments, joint surface texture and spatial relationships of bones of the hind limb. Computer reconstructions of the knee and hip show promise as a means of investigating the etiology of congenital hip dislocation.
Bargiotas, Konstantinos; Wohlrab, David; Sewecke, Jeffrey J; Lavinge, Gregory; DeMeo, Patrick J; Sotereanos, Nicholas G
2007-03-01
Knee arthrodesis can be an effective treatment option for relieving pain and restoring some function after the failure of a total knee arthroplasty as the result of infection. The purpose of the present study was to review the outcome of a staged approach for arthrodesis of the knee with a long intramedullary nail after the failure of a total knee arthroplasty as the result of infection. We reviewed the results for twelve patients who underwent knee arthrodesis after the removal of a prosthesis because of infection. The study group included seven women and five men who had an average age of sixty-eight years at the time of the arthrodesis. All patients were managed with a staged protocol. Implant removal, débridement, and insertion of antibiotic cement spacers was followed by the administration of systemic antibiotics. Provided that clinical and laboratory data suggested eradication of the infection, arthrodesis of the affected knee with use of a long intramedullary nail was carried out. Clinical and laboratory evaluation and radiographic analysis were performed after an average duration of follow-up of 4.1 years. Solid union was achieved in ten of the twelve knees. The average time to union was 5.5 months. One patient had an above-the-knee amputation because of recurrence of infection. In another patient, nail breakage occurred three years following implantation. The average limb-length discrepancy was 5.5 cm. The mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score improved from 41 to 64 points. None of the seven patients who underwent arthrodesis with a technique involving convex-to-concave reamers had a complication, and the average time to union for these seven patients was shorter than that for the remaining five patients (4.3 compared with 7.4 months). We believe that obtaining large surfaces of bleeding contact bone during arthrodesis following staged treatment of an infection at the site of a failed total knee arthroplasty contributes to stability and enhances bone-healing. Staged arthrodesis with use of a long intramedullary nail and convex-to-concave preparation of bone ends provided a painless functional gait with low complication and reoperation rates in this challenging group of patients.
Bargiotas, Konstantinos; Wohlrab, David; Sewecke, Jeffrey J; Lavinge, Gregory; Demeo, Patrick J; Sotereanos, Nicholas G
2006-03-01
Knee arthrodesis can be an effective treatment option for relieving pain and restoring some function after the failure of a total knee arthroplasty as the result of infection. The purpose of the present study was to review the outcome of a staged approach for arthrodesis of the knee with a long intramedullary nail after the failure of a total knee arthroplasty as the result of infection. We reviewed the results for twelve patients who underwent knee arthrodesis after the removal of a prosthesis because of infection. The study group included seven women and five men who had an average age of sixty-eight years at the time of the arthrodesis. All patients were managed with a staged protocol. Implant removal, débridement, and insertion of antibiotic cement spacers was followed by the administration of systemic antibiotics. Provided that clinical and laboratory data suggested eradication of the infection, arthrodesis of the affected knee with use of a long intramedullary nail was carried out. Clinical and laboratory evaluation and radiographic analysis were performed after an average duration of follow-up of 4.1 years. Solid union was achieved in ten of the twelve knees. The average time to union was 5.5 months. One patient had an above-the-knee amputation because of recurrence of infection. In another patient, nail breakage occurred three years following implantation. The average limb-length discrepancy was 5.5 cm. The mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score improved from 41 to 64 points. None of the seven patients who underwent arthrodesis with a technique involving convex-to-concave reamers had a complication, and the average time to union for these seven patients was shorter than that for the remaining five patients (4.3 compared with 7.4 months). We believe that obtaining large surfaces of bleeding contact bone during arthrodesis following staged treatment of an infection at the site of a failed total knee arthroplasty contributes to stability and enhances bone-healing. Staged arthrodesis with use of a long intramedullary nail and convex-to-concave preparation of bone ends provided a painless functional gait with low complication and reoperation rates in this challenging group of patients.
Flynn, John M; Ramirez, Norman; Betz, Randal; Mulcahey, Mary Jane; Pino, Franz; Herrera-Soto, Jose A; Carlo, Simon; Cornier, Alberto S
2010-01-01
A syndrome of children with short stature, bilateral hip dislocations, radial head dislocations, carpal coalitions, scoliosis, and cavus feet in Puerto Rican children, was reported by Steel et al in 1993. The syndrome was described as a unique entity with dismal results after conventional treatment of dislocated hips. The purpose of this study is to reevaluate this patient population with a longer follow-up and delineate the clinical and radiologic features, treatment outcomes, and the genetic characteristics. This is a retrospective cohort study of 32 patients in whom we evaluated the clinical, imaging data, and genetic characteristics. We compare the findings and quality of life in patients with this syndrome who have had attempts at reduction of the hips versus those who did not have the treatment. Congenital hip dislocations were present in 100% of the patients. There was no attempt at reduction in 39% (25/64) of the hips. In the remaining 61% (39/64), the hips were treated with a variety of modalities fraught with complications. Of those treated, 85% (33/39) remain dislocated, the rest of the hips continue subluxated with acetabular dysplasia and pain. The group of hips that were not treated reported fewer complaints and limitation in daily activities compared with the hips that had attempts at reduction. Steel syndrome is a distinct clinical entity characterized by short stature, bilateral hip and radial head dislocation, carpal coalition, scoliosis, cavus feet, and characteristic facial features with dismal results for attempts at reduction of the hips. Prognostic Study Level II.
Intrathoracic migration of an unbent Steinmann pin
R, Estfan; S, Sarkar
2014-01-01
Steinmann pins are known to be used as a shoulder stabilisation device in recurrent dislocation. Although rare, their potential to migrate within the thorax has been reported. We present the case of an 87-year-old man who was treated for recurrent left shoulder dislocation with pinning using a Steinmann pin. He presented eight days postoperatively with the pin impaling the aortic adventitia. To our knowledge, this is only the fifth case report of such an event. Awareness of this complication and attempts to prevent its occurrence are critical as the outcome can be fatal. PMID:24780661
Neglected Monteggia fracture dislocations in children: a systematic review.
Goyal, Tarun; Arora, Shobha S; Banerjee, Sumit; Kandwal, Pankaj
2015-05-01
Monteggia fractures are uncommon and frequently missed injuries in children. This article aims to study, in a systematic manner, the surgical management and complications of treatment of chronic radial head dislocations. After screening of relevant abstracts, a total of 28 studies were included in the systematic review. A narrative synthesis of various treatment modalities has been discussed. This article concludes that open reduction should be attempted unless dysmorphism of the radial head restricts it. Open reduction with ulnar osteotomy with or without annular ligament reconstruction is the most commonly performed procedure and is expected to result in reduced pain and elbow deformity.
Raskolnikov, Dima; Slover, James D.; Egol, Kenneth A.
2013-01-01
Background One of the most catastrophic outcomes following total knee arthroplasty (TKA) is a chronic periprosthetic infection with concomitant failure of the knee extensor mechanism. This study retrospectively reviewed the clinical records of 7 patients who were treated with a 6 axis circular external fixation frame (Taylor Spatial Frame (TSF)) for this condition. Fusion was achieved in 5 of 7 patients (71%) at an average of 8.4 months after surgery. Complications occurred in the treatment of 5 of 7 patients (71%). Infection was controlled in all cases. The TSF presents another valuable tool, which the orthopaedic surgeon should consider when treating these difficult cases. Purpose To evaluate the use of the Taylor Spatial Frame (TSF) to achieve knee arthrodesis in patients with chronically infected total knee arthroplasties (TKAs) with concomitant failure of the knee extensor mechanism. Methods We retrospectively evaluated the clinical records of 7 patients who were referred to our tertiary care orthopaedic medical center with multiple failed knee arthroplasties, chronic draining infection and complete loss of the extensor mechanism. All patients were treated with a similar protocol including, debridement and bony stabilization with an adjustable, 6 axis circular external fixation frame (TSF). Hospital charts were reviewed for sociodemographic information, surgical details, hospital course and complications. Radiographs were reviewed for healing and alignment. Follow up included clinical examination and radiographs. Results The mean age of the patients was 70.9 years (range, 59 – 83 years) at the time of application of the TSF. There were 3 men and 4 women. The average time between TKA and diagnosis of infection was 30.7 months (range, 2.6 – 67.0 months). The 7 patients had undergone an average of 3.3 prior surgical procedures (range, 2-4 procedures) on the ipsilateral extremity. Fusion was achieved in 5 of 7 patients (71%) at an average of 8.4 months after surgery (range, 6 – 10.5 months). Complications occurred in the treatment of 5 of 7 patients (71%) and included infection at the site of the pin tracks (5 patients), antibiotic- induced acute renal failure (1 patient), wound breakdown requiring flap closure (1 patient), and femur fracture secondary to a fall after placement of the antibiotic spacer but before application of the TSF (1 patient). The 2 patients in whom failure of fusion occurred returned to ambulation with an assistive device. Infection was controlled in all cases. Conclusion Fusion and complication rates in this cohort are comparable to those reported in previous studies using other techniques to achieve external fixation. The TSF is a versatile external fixator that offers another tool, which the orthopaedic surgeon should consider when treating these difficult cases. PMID:24027456
Yan, Ning; Yang, Anli; Liu, Xiaodong; Cai, Feng; Liu, Liang; Chang, Shimin
2014-03-01
Although the cannulated screw and cable (CSC) tension band technique is an effective method for fixation of transverse patellar fractures, it has shortcomings, such as extensive soft tissue damage, osseous substance damage, and complex manipulation. We conducted a retrospective comparison of the adjustable patella grapple (APG) technique and the CSC tension band technique. We retrospectively reviewed 78 patients with transverse patellar fractures (45 in the APG group and 33 in the CSC group). Follow-up was 18 months. Comparison criteria were operation time, fracture reduction, fracture healing time, the knee injury and osteoarthritis outcome score for knee function, and complications. The APG group showed shorter operation time and equal fracture reduction, fracture healing time, and knee function compared with the CSC group. Eleven patients in the APG group experienced skin irritation generated by implants. There was no complication in the CSC group. The APG technique should be considered as an alternative method for treatment of transverse patellar fractures.
Bhave, Anil; Corcoran, James; Cherian, Jeffery J; Mont, Michael A
2016-01-01
Knee stiffness is a common complication after total knee arthroplasty (TKA). Despite studies published on the surgical management of reduced range of motion (ROM) after TKA, there is limited evidence on the nonoperative management of joint and soft tissue imbalances possibly contributing to reduced knee ROM. This report assesses changes in ROM, pain, function, and patellar tendon length after Astym® joint mobilization use. A 38-year-old male professional skier had a right TKA 3 months before presentation with 2 subsequent manipulations under anesthesia secondary to persistent knee stiffness. He had patellar baja on radiograph, a reduced arc of ROM, reduced patellar mobility and muscular extensibility, and pain to palpation along the patellar tendon. He had 12 visits of physical therapy with the use of Astym®, patellar mobilization, and tibio-femoral mobilizations with movement. The patient also used a customized knee device at home for prolonged knee extension stretching. The patient was treated for 12 visits, along with home use of customized bracing for knee extension. Significant improvements were seen in pain, function, and ROM. He returned to work full-time, ambulated prolonged distances, and negotiated stairs pain-free. He also demonstrated resolution of patellar baja radiographically. Conservative management of recalcitrant knee joint stiffness after primary TKA can be effective in restoring knee mobility and reducing pain and activity limitation. A multimodal approach using Astym® treatment, customized knee bracing, and targeted joint mobilization can be effective in resolving knee joint stiffness.
Wind, Rutger J P; Heesterbeek, Petra J C; Wymenga, Ate B
2018-06-11
Trochlear dysplasia is a major risk factor predisposing to patellar instability and has been reported to occur in up to 85% of patients with recurrent patellar dislocation. Different operative techniques have been described to correct trochlear dysplasia, including the Bereiter technique, in which subchondral bone is removed and the cartilage can be compressed into a U-shaped groove. The hypothesis was that after a Bereiter-type trochleoplasty combined with medialisation of the tibial tubercle and MPFL reconstruction, patellar pain and instability decreased and anatomic reconstruction can be seen radiographically after 5-year follow-up. Between 2004 and 2011, a combined procedure including Bereiter-type trochleoplasty was performed on 21 consecutively included patients (22 knees) with objective patellar instability and severe trochlear dysplasia. Instability and pain were assessed preoperatively and 3, 6, 12, 24 and 60 months postoperatively with the visual analogue scale (VAS) for pain and instability, Kujala, International Knee Documentation Committee Subjective Knee Evaluation (IKDC SKE) and Short Form Health Survey (SF-36). Pre- and postoperatively, a true lateral radiograph was made to investigate the presence of the crossing sign and to measure the trochlear bump and trochlear depth, as well as a sunrise patella view to measure the sulcus angle. VAS pain and instability, Kujala and IKDC SKE improved significantly 5 years after trochleoplasty (p < 0.05). SF-36 showed no significant improvement. None of the patients reported patellar dislocations postoperatively. Sport activities remained limited. Postoperative radiographs showed no crossing sign. There was a significant increase in trochlear depth (p < 0.0001) and also a significant decrease in trochlear bump and sulcus angle (both p < 0.0001). A combined procedure consisting of Bereiter-type trochleoplasty, medialisation of the tibial tubercle and MPFL reconstruction in patients with objective patellar instability and severe trochlear dysplasia resulted in a clear decrease of pain and instability. Radiological assessment showed anatomical reconstruction. Nevertheless, residual symptoms remain and the possibility of future cartilage damage is uncertain. IV.
Knee arthrodesis using an intramedullary nail.
Crockarell, John R; Mihalko, Marc J
2005-09-01
Fifteen knee arthrodeses using an intramedullary nail were performed in 15 patients. Indications included 11 failed total knee arthroplasties (10 of 11 septic). A retrospective review revealed 100% fusion rate. Complications included 4 cases of painful hardware, 1 trochanteric bursitis, and 1 deep infection. Ten patients were available for assessment at 7 years follow-up. Average leg length discrepancy was 3.7 cm. Anatomic axis averaged 1.3 degrees valgus. Flexion angle averaged 3.5 degrees . Compared with age-matched controls, our patients fared significantly worse in physical functioning, physical role, bodily pain, vitality, and social functioning. Arthrodesis of the knee with an intramedullary nail provides a reliable means of fusion with reasonable alignment. These patients have high rates of pain and diminished functional status.
Xie, Wenjun; Zhang, Yu; Qin, Xiaodong; Song, Lijun; Chen, Qun
2018-03-01
High fibular osteotomy has been preliminarily proved to be an effective treatment of knee osteoarthritis by excising a segment of bone at the proximal part of fibula. This imaginative procedure is clinical validated by its instant and explicit knee pain resorption and eventually deformity correction. The rationale of this treatment is named non-uniform settlement of the tibial plateau and used to elucidate the cause of knee joint degeneration, but cannot illuminate the reason of prompt postoperative pain resorption faithfully. To assist in better understanding of this therapeutic method and raising alert to possible unexpected complications, we proposed a new theory to elucidate the pain relief mechanism.
Cementless Total Knee Arthroplasty in Patients Older Than 75 Years.
Newman, Jared M; Khlopas, Anton; Chughtai, Morad; Gwam, Chukwuweike U; Mistry, Jaydev B; Yakubek, George A; Harwin, Steven F; Mont, Michael A
2017-11-01
Some surgeons have been hesitant to use cementless fixation for total knee arthroplasty (TKA) in elderly patients due to concerns regarding successful bone biological fixation. Therefore, this study evaluated: (1) implant survivorship, (2) functional outcomes, (3) radiographic outcomes, and (4) complications in patients over 75 years of age who underwent cementless total knee arthroplasty. A total of 134 patients (142 TKAs) older than 75 years at a single institution between June 2008 and June 2014 were retrospectively reviewed. Their mean follow-up was 4 years (range: 2-8 years). The cohort consisted of 91 women and 43 men who had a mean age of 80 years (range: 76 to 88 years). The preoperative diagnoses were osteoarthritis ( n = 107 patients), rheumatoid arthritis ( n = 21 patients), and osteonecrosis ( n = 6 patients). Descriptive statistics were used to calculate the means and ranges and a Kaplan-Meier analysis was performed to determine the aseptic and all cause implant survivorship. Radiographic evaluation was performed using the new Knee Society Radiographic Evaluation and Scoring System. Functional outcomes at the final follow-up as well as all medical and surgical complications were recorded for each patient. The aseptic implant survivorship was 99.3% (95% CI: 7.9-8.1), and the all cause implant survivorship was 98.6% (95% CI: 7.9-8.1). There was one aseptic revision and one septic revision. At the latest follow-up the mean Knee Society pain score was 93 points (range, 80-100 points), and the mean Knee Society function score was 84 points (range, 70-90 points). On radiographic evaluation, there were no progressive radiolucencies, subsidence, and loosening of prostheses at the latest follow-up. The use of cementless TKA demonstrated excellent survivorship, mid-term clinical and functional outcomes, as well as no progressive radiolucencies or subsidence in patients older than 75 years. In addition, there was a low rate of surgical and medical complications. Therefore, cementless TKA may be a good option for patients older than 75 years. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
[Two cases of rehabilitation in Ehler-Danlos syndrome].
Le Tallec, H; Lassalle, A; Khenioui, H; Durufle, A; Plassat, R; Gallien, P
2006-03-01
Ehlers-Danlos syndrome is rare and little known. It comprises a heterogeneous group of heritable connective tissue disorders characterized by articular hypermobility, skin extensibility and tissue fragility. Diagnosis may be difficult and often delayed. Here we describe 2 cases of women with Ehlers-Danlos syndrome. The first had scoliosis with back pain and joint hypermobility. The second presented with hypermobility and joint dislocation, which increased during pregnancy. In these 2 cases, rehabilitation management produced clinical improvement. Orthopaedic complications such joint pain, joint swelling, joint dislocation, back pain, with walking and hand function disability are the main problems in Ehlers-Danos syndrome. Surgery may be necessary to correct dislocated joints but is often not sufficient to resolve the handicap, and physical therapy has an important place in management. Ehlers-Danlos syndrome is an evolving disease that can lead to great impairment. Thus, physicians must be aware of this syndrome to offer the best management, with the appropriate use of orthotic devices, specific strengthening routines, education in proper body mechanics and assistive devices, to prevent joint dislocation and subluxations responsible for pain and handicap.
Shaw, A; Stephen, AB; Lund, JN; Bungay, P; DeNunzio, M
2009-01-01
Arterial pseudoaneurysm formation of the genicular vessels following orthopaedic surgery to the knee is an extremely rare occurrence. Here we report the successful management of two cases as a complication of total knee arthroplasty and a tibial interlocking nail, utilising coil embolisation by interventional radiological techniques and negating the need for further surgery. To our knowledge this is one of the few reported cases of pseudoaneurysms of the descending genicular artery secondary to drain placement and only the second following tibial interlocking nail placement. PMID:22470647
Zhu, Zhonglin; Ding, Hui; Dang, Xiao; Tang, Jing; Zhou, Yixin; Wang, Guangzhi
2010-01-01
Fixed-bearing posterior-stabilized (PS) total knee arthroplasty (TKA) has been used in Asian countries for several years, but few studies have investigated differences in the kinematic properties of the patellar tendon after standard PS TKA as compared to high-flex PS TKA. To quantify the in vitro three-dimensional (3D) kinematics of the patellar tendon during passive high flexion and full extension before and after two different types of PS TKAs. Six fresh-frozen cadaveric knees were tested under the following conditions: the unaltered state, status-post traditional PS prostheses (Simth-nephew GENESIS II) replacement, and status-post high-flexion PS prostheses replacement. The soft tissue around the knee and the quadriceps muscle were preserved, then tested under the load of a specific weight in an Oxford knee rig. We designed a specialized rigid body with four active markers fixed to each bone to track the 3D passive motion of the cadaveric knees. Flexion and extension was controlled by the knee rig and captured by an Optotrak Certus high precision optical tracking system. The attachment sites of the patellar tendon were registered as virtual markers to calculate the 3D kinematics. The patellar tendon of the unaltered knee and both TKA knees showed similar deformation. We found the length of the patellar tendon changed significantly during a motion from full extension to 30°, but there was no significant change in length while undergoing a motion from 30° to full flexion. Both the sagittal plane and coronal plane angles of the patellar tendon decreased after PS TKAs. There was no significant difference in patellar tendon kinematics between the two types of PS TKAs. We believe the changes observed in the sagittal plane and coronal plane angles of the patellar tendon after PS TKAs may influence the extensor mechanism and be an important cause of patella-femoral complications. These data may be used to assess patella-femoral complications after surgery so as to improve the design of high-flexion TKAs for Asians and achieve long-term stability.
Gallart, X; Gomez, J C; Fernández-Valencia, J A; Combalía, A; Bori, G; García, S; Rios, J; Riba, J
2014-01-01
To evaluate the short-term results of an ultra high molecular weight polyethylene retentive cup in patients at high risk of dislocation, either primary or revision surgery. Retrospective review of 38 cases in order to determine the rate of survival and failure analysis of a constrained cemented cup, with a mean follow-up of 27 months. We studied demographic data, complications, especially re-dislocations of the prosthesis and, also the likely causes of system failure analyzed. In 21.05% (8 cases) were primary surgery and 78.95% were revision surgery (30 cases). The overall survival rate by Kaplan-Meier method was 70.7 months. During follow-up 3 patients died due to causes unrelated to surgery and 2 infections occurred. 12 hips had at least two previous surgeries done. It wasn't any case of aseptic loosening. Four patients presented dislocation, all with a 22 mm head (P=.008). Our statistical analysis didn't found relationship between the abduction cup angle and implant failure (P=.22). The ultra high molecular weight polyethylene retentive cup evaluated in this series has provided satisfactory short-term results in hip arthroplasty patients at high risk of dislocation. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
[Dislocation of the PIP-Joint - Treatment of a common (ball)sports injury].
Müller-Seubert, Wibke; Bührer, Gregor; Horch, Raymund E
2017-09-01
Background Fractures or fracture dislocations of the proximal interphalangeal joint often occur during sports or accidents. Dislocations of the PIP-joint are the most common ligamentary injuries of the hand. As this kind of injury is so frequent, hand surgeons and other physicians should be aware of the correct treatment. Objectives This paper summarises the most common injury patterns and the correct treatment of PIP-joint dislocations. Materials and Methods This paper reviews the current literature and describes the standardised treatment of PIP-joint dislocations. Results What is most important is that reposition is anatomically correct, and this should be controlled by X-ray examination. Depending on the instability and possible combination with other injuries (e. g. injury to the palmar plate), early functional physiotherapy of the joint or a short immobilisation period is indicated. Conclusions Early functional treatment of the injured PIP-joint, initially using buddy taping, is important to restore PIP-joint movement and function. Depending on the injury, joint immobilisation using a K-wire may be indicated. Detailed informed consent is necessary to explain to the patient the severity of the injury and possible complications, such as chronic functional disorders or development of arthrosis. © Georg Thieme Verlag KG Stuttgart · New York.
Thrombus in Transit: A Potentially Life-threatening Complication of Cerebral Sinus Thrombosis.
Petracca, Martina; Calandrelli, Rosalinda; Broccolini, Aldobrando; Caliandro, Pietro; Della Marca, Giacomo; Frisullo, Giovanni; Morosetti, Roberta; Profice, Paolo; Lamendola, Priscilla; Pennestrì, Faustino; Pilato, Fabio
2017-01-01
We report the case of a 41-year-old, 7-weeks-pregnant patient, presenting with headache and generalized seizure due to cerebral venous thrombosis complicated by jugular thrombosis and thrombus dislocation into right cardiac cavities. The patient was treated with intravenous heparin, and underwent embolectomy in extracorporeal circulation. This case illustrates the variability of cerebral venous thrombosis progression and a potentially life-threatening condition even during anticoagulant therapy.
Eshoj, Henrik; Rasmussen, Sten; Frich, Lars Henrik; Hvass, Inge; Christensen, Robin; Jensen, Steen Lund; Søndergaard, Jens; Søgaard, Karen; Juul-Kristensen, Birgit
2017-02-28
Anterior shoulder dislocation is a common injury and may have considerable impact on shoulder-related quality of life (QoL). If not warranted for initial stabilising surgery, patients are mostly left with little to no post-traumatic rehabilitation. This may be due to lack of evidence-based exercise programmes. In similar, high-impact injuries (e.g. anterior cruciate ligament tears in the knee) neuromuscular exercise has shown large success in improving physical function and QoL. Thus, the objective of this trial is to compare a nonoperative neuromuscular exercise shoulder programme with standard care in patients with traumatic anterior shoulder dislocations (TASD). Randomised, assessor-blinded, controlled, multicentre trial. Eighty patients with a TASD will be recruited from three orthopaedic departments in Denmark. Patients with primary or recurrent anterior shoulder dislocations due to at least one traumatic event will be randomised to 12 weeks of either a standardised, individualised or physiotherapist-supervised neuromuscular shoulder exercise programme or standard care (self-managed shoulder exercise programme). Patients will be stratified according to injury status (primary or recurrent). Primary outcome will be change from baseline to 12 weeks in the patient-reported QoL outcome questionnaire, the Western Ontario Shoulder Instability Index (WOSI). This trial will be the first study to compare the efficacy and safety of two different nonoperative exercise treatment strategies for patients with TASD. Moreover, this is also the first study to investigate nonoperative treatment effects in patients with recurrent shoulder dislocations. Lastly, this study will add knowledge to the shared decision-making process of treatment strategies for clinical practice. ClinicalTrials.gov, identifier: NCT02371928 . Registered on 9 February 2015 at the National Institutes of Health Clinical Trials Protocol Registration System.
Optimized cartilage visualization using 7-T sodium ((23)Na) imaging after patella dislocation.
Widhalm, Harald K; Apprich, Sebastian; Welsch, Goetz H; Zbyn, Stefan; Sadoghi, Patrick; Vekszler, György; Hamböck, Martina; Weber, Michael; Hajdu, Stefan; Trattnig, Siegfried
2016-05-01
Retropatellar cartilage lesions often occur in the course of recurrent patella dislocation. Aim of this study was to develop a more detailed method for examining cartilage tissue, in order to reduce patient discomfort and time of care. For detailed diagnosing, a 7-T MRI of the knee joint and patella was performed in nine patients, with mean age of 26.4 years, after patella dislocation to measure the cartilage content in three different regions of interest of the patella. Axial sodium ((23)Na) images were derived from an optimized 3D GRE sequence on a 7-T MR scanner. Morphological cartilage grading was performed, and sodium signal-to-noise ratio (SNR) values were calculated. Mean global sodium values and SNR were compared between patients and volunteers. Two out of nine patients showed a maximum cartilage defect of International Cartilage Repair Society (ICRS) grade 3, three of grade 2, three of grade 1, and one patient showed no cartilage defect. The mean SNR in sodium images for cartilage was 13.4 ± 2.5 in patients and 14.6 ± 3.7 in volunteers (n.s.). A significant negative correlation between age and global sodium SNR for cartilage was found in the medial facet (R = -0.512; R (2) = 0.26; p = 0.030). Mixed-model ANOVA yielded a marked decrease of the sodium SNR, with increasing grade of cartilage lesions (p < 0.001). Utilization of the (23)Na MR imaging will make earlier detection of alterations to the patella cartilage after dislocation possible and will help prevent subsequent disease due to start adequate therapy earlier in the rehabilitation process. II.
Spencer, Brian A; Mont, Michael A; McGrath, Mike S; Boyd, Bradley; Mitrick, Michael F
2009-12-01
New technology using magnetic resonance imaging (MRI) allows the surgeon to place total knee replacement components into each patient's pre-arthritic natural alignment. This study evaluated the initial intra-operative experience using this technique. Twenty-one patients had a sagittal MRI of their arthritic knee to determine component placement for a total knee replacement. Cutting guides were machined to control all intra-operative cuts. Intra-operative events were recorded and these knees were compared to a matching cohort of the senior surgeon's previous 30 conventional total knee replacements. Post-operative scanograms were obtained from each patient and coronal alignment was compared to previous studies using conventional and computer-assisted techniques. There were no intra-operative or acute post-operative complications. There were no differences in blood loss and there was a mean decrease in operative time of 14% compared to a cohort of patients with conventional knee replacements. The average deviation from the mechanical axis was 1.2 degrees of varus, which was comparable to previously reported conventional and computer-assisted techniques. Custom-fit total knee replacement appeared to be a safe procedure for uncomplicated cases of osteoarthritis.
Knee flexion deformity from poliomyelitis treated by supracondylar femoral extension osteotomy.
de Moraes Barros Fucs, Patricia M; Svartman, Celso; de Assumpção, Rodrigo Montezuma César
2005-12-01
Between April 1979 and August 1993, we treated 39 patients (49 knees) with knee flexion deformity after Poliomyelitis. All were subjected to fractional hamstring lengthening and supracondylar femoral extension osteotomy in the same surgical procedure. The goal was to correct the deformity and fit the lower extremities in long braces to improve or promote gait. Patients' mean age was 19.5 (6.5-39) years and the mean knee flexion deformity was 65 degrees (24-158 degrees). The mean follow-up was 15.5 (11.5-25) years. Postoperatively, 22 knees had full extension, in 26 there was an extension lag between -1 and -10 degrees and in one a lag greater than 10 degrees. There were no neurovascular complications and all patients were fitted with long leg braces. Surgical planning is important, especially in severe deformities, where shortening of the femur is necessary to facilitate the osteotomy and relax the neurovascular structures.
Suri, Harpreet Singh; Gangrade, Kewal
2016-01-01
Introduction High energy intra-articular fractures involving the tibial plateau causes various problems related to management like wound dehiscence, severe comminution leading to malalignment and delayed complications like varus collapse, implant failure and arthritis of knee joint. Aim This study was done to determine functional, radiological outcome and the complications of Schatzker V and VI tibial plateau fractures treated with bipillar plating with dual plates with a regular follow-up of atleast 3 years. Materials and Methods Total 34 cases of tibial plateau fracture type V and VI treated with dual plating were studied from January 2011 to December 2013 in KIMS Hospital were followed for minimum of 3 years. The patients were operated through an anterolateral approach for lateral plate and a medial column plate was put through a minimally invasive medial approach or an open posteromedial approach. Results Total 34 patients were evaluated postoperatively thoroughly for functional outcome using The Knee Society Score and radiological outcomes by Modified Rasmussen Assessment criteria which showed 29 patients (85.29%) had excellent and 5 patients (14.71%) had good objective knee society score. 24 patients (70.59%) had excellent, 8 patients (23.53%) had good and 1patient (2.94%) were each of poor and fair functional knee society score. Eleven patients (32.35%) had excellent, 21patients (61.76%) had good and 2 patients (5.88%) had fair radiological outcome. Conclusion We conclude that open reduction and internal fixation of high-energy tibial plateau fractures with dual plates via 2 incisions gives excellent to good functional outcome with minimal soft tissue complications. Thus, a minimally invasive approach should be used which helps in preventing soft tissue problems and helps in early wound healing. Fixation done by bipillar plating is important for early mobilization of knee joint. Early mobilization leads to better range of movements and thereby better functional outcome. PMID:27437315
Xuan, Tao; Xu, Bin; Xu, Honggang; Wang, Hao
2009-01-01
To explore the treatment of patellofemoral joint disorders with radiofrequency vaporization under arthroscopy. From June 2004 to June 2007, 86 cases of patellofemoral joint disorder (98 knees) were treated by lateral retinacular release or medial retinacular tighten added, and combined with bipolar radiofrequency chondroplasty under arthroscopy. There were 30 males (34 knees) and 56 females (64 knees), aging 15-68 years (mean 40 years). The locations were left in 42 cases, right in 32 cases, both sides in 12 cases. The disease course was 3 months to 6 years (mean 30.5 months). In 98 knees, there were 28 knees of static patellar tilt, 10 knees of static patellar subluxation, 45 knees of dynamic patellar tilt and 15 knees of dynamic patellar subluxation. The Lysholm knee score preoperatively was 57.72 +/- 8.86. The patellofemoral cartilage abnormality were classified according to the Outerbridge grade (18 knees of grade I, 36 knees of grade II, 32 knees of grade III and 12 knees of grade IV). The incisions healed by first intention without complications such as infection or hemarthrosis. Seventy-five cases (82 knees) were followed up 8-37 months (mean 20.6 months). One month after operation, the patellofemoral joint pain was relieved remarkably, the knee joint activity was good and the radiological outcomes was also satisfactory. Six months after operation, the Lysholm knee score was improved significantly in patients of grades I, II and III (P < 0.05), while there was no significant change in patients of grade IV (P > 0.05). The postoperative score was 69.95 +/- 5.42 (P < 0.05). Radiofrequency vaporization chondroplasty and soft tissue balance under arthroscopy are advantageous in terms of easy operation, less injury, slight reaction and have good effect on patellofemoral joint disorders.
Hoarseness caused by arytenoid dislocation after surgery for lung cancer.
Kurihara, Nobuyasu; Imai, Kazuhiro; Minamiya, Yoshihiro; Saito, Hajime; Takashima, Shinogu; Kudo, Satoshi; Kawaharada, Yasushi; Ogawa, Jun-Ichi
2014-12-01
The patient was a 64-year-old woman with no history of laryngeal disorders. She underwent video-assisted right lower lobectomy and node dissection for lung cancer. Using a stylet while the patient was under general anesthesia, tracheal intubation with a 35-French gauge left-sided double-lumen endobronchial tube was successfully performed on the first attempt. The patient developed slight hoarseness on postoperative day 1, and we initially suspected recurrent laryngeal nerve paralysis caused by the surgery, which we elected to treat conservatively. However, because her hoarseness had not improved 4 months after surgery, we evaluated her vocal cords using laryngoscopy. This revealed severe dysfunction of the right vocal cord and arytenoid dislocation, which we treated through reduction using a balloon catheter. By 6 months, the patient's vocal cord mobility had improved. Arytenoid dislocation is a rare complication, but should be suspected when patients have right vocal fold paralysis after lung cancer surgery.
Arthroscopic procedures for the treatment of anterior shoulder instability: local experiences.
Choi, S T; Tse, P Y T
2005-04-01
To review the outcomes of arthroscopic stabilisation procedures for the treatment of recurrent anterior shoulder dislocation. Retrospective study. Regional hospital, Hong Kong. Patients receiving arthroscopic stabilisation procedures for recurrent anterior shoulder dislocation between 1999 and 2003. Functional outcomes including pain, range of motion, and activity level were assessed using the Constant score. Intra-operative findings were also discussed. A total of 18 arthroscopic stabilisation procedures were performed for the treatment of recurrent shoulder instability. Two cases converted to open procedures were excluded from this review. The overall outcomes were good and seven patients reported a full recovery. Fourteen out of 16 patients reported minimal or no pain, and the mean Constant score was 80. There were no cases of re-dislocation and no major complication was noted. All the reviewed patients had a satisfactory functional recovery. Therefore, we believe that the use of arthroscopic stabilisation procedure can produce a favourable outcome for appropriate shoulder pathologies.
Yang, Baohui; Lu, Teng
2017-01-01
For patients with AS and lower cervical spine fractures, surgical methods have mainly included the single anterior approach, single posterior approach, and combined anterior-posterior approach. However, various surgical procedures were utilized because the fractures have not been clearly classified according to presence of displacement in these previous studies. Consequently, controversies have been raised regarding the selection of the surgical procedure. This study retrospective analysis was conducted in 12 patients with AS and lower cervical spine fractures and dislocations and explored single-session combined anterior-posterior approach for the treatment of AS with obvious displaced lower cervical spine fractures and dislocations which has demonstrated advantages such as good stabilization, satisfied fracture healing, and easy postoperative cares. However, to some extent, the difficulty and risk of this approach should be considered. Attention should be paid to the prevention of perioperative complications. PMID:28133616
Dislocation Majorana zero modes in perovskite oxide 2DEG
Chung, Suk Bum; Chan, Cheung; Yao, Hong
2016-01-01
Much of the current experimental efforts for detecting Majorana zero modes have been centered on probing the boundary of quantum wires with strong spin-orbit coupling. The same type of Majorana zero mode can also be realized at crystalline dislocations in 2D superconductors with the nontrivial weak topological indices. Unlike at an Abrikosov vortex, at such a dislocation, there is no other low-lying midgap state than the Majorana zero mode so that it avoids usual complications encountered in experimental detections such as scanning tunneling microscope (STM) measurements. We will show that, using the anisotropic dispersion of the t2g orbitals of Ti or Ta atoms, such a weak topological superconductivity can be realized when the surface two-dimensional electronic gas (2DEG) of SrTiO3 or KTaO3 becomes superconducting, which can occur through either intrinsic pairing or proximity to existing s-wave superconductors. PMID:27139319
Two-year follow-up evaluation of surgical treatment for thoracolumbar fracture-dislocation.
Hao, Dingjun; Wang, Wentao; Duan, Kun; Ma, Minjie; Jiang, Yong; Liu, Tuanjiang; He, Baorong
2014-10-01
A randomized, controlled clinical trial. This randomized controlled clinical trial was aimed at comparing the clinical outcomes of combined posteroanterior (P-A) fusion and transforaminal thoracic interbody fusion (TTIF) in cases of thoracolumbar fracture-dislocation. The optimal treatment strategy for thoracolumbar fracture-dislocation remains controversial. Sixty-one patients presenting with acute fracture-dislocation of the thoracolumbar joint between March 2010 and December 2011 were enrolled and randomly assigned to the P-A or TTIF group. The radiological outcome was assessed by acquiring radiographs in the standing position and computed tomographic scans. The clinical outcome was measured in terms of the American Spinal Injury Association score, visual analogue scale score, and Oswestry Disability Index. Moreover, we assessed the severity of overall morbidity and morbidity at the donor site in the 2 patient groups. The Student t and χ tests were used for the analysis of independent variables and categorical data, respectively. Only 57 of the enrolled patients were available for the required 24-month follow-up period, 27 underwent TTIF and 30 underwent P-A fusion. Both treatments were similar with respect to the fusion rate, extent of decompression, loss of correction, rate of instrumentation failure, American Spinal Injury Association score, visual analogue scale score, and Oswestry Disability Index (P > 0.05). However, the blood loss, operating time, and rate of perioperative complications were greater in the P-A group than in the TTIF group (P < 0.05). The clinical and radiological outcomes were similar for both the treatment procedures. However, our findings suggest that TTIF allows for safe interbody fusion and circumferential decompression, requires only a posterior approach, and is associated with a lower incidence of surgery-related complications. 2.
Gutkowska, Olga; Martynkiewicz, Jacek; Mizia, Sylwia; Bąk, Michał; Gosk, Jerzy
2017-09-01
Injury to the infraclavicular brachial plexus is an uncommon but serious complication of shoulder dislocation. This work aims to determine the effectiveness of operative treatment in patients with this type of injury. Thirty-three patients (26 men and 7 women; mean age, 45 years and 3 months) treated operatively for brachial plexus injury resulting from shoulder dislocation between the years 2000 and 2013 were included in this retrospective case series. Motor function of affected limbs was assessed pre- and postoperatively with the use of the British Medical Research Council (BMRC) scale. Sensory function in the areas innervated by ulnar and median nerves was evaluated with the BMRC scale modified by Omer and Dellon and in the remaining areas with the Highet classification. Follow-up lasted 2-10 years (mean, 5.1 years). Good postoperative recovery of nerve function was observed in 100% of musculocutaneous, 93.3% of radial, 66.7% of median, 64% of axillary, and 50% of ulnar nerve injuries. No recovery was observed in 5.6% of median, 6.7% of radial, 10% of ulnar, and 20% of axillary nerve injuries. Injury to a single nerve was associated with worse treatment outcome than multiple nerve injury. Obtaining improvement in peripheral nerve function after injury resulting from shoulder dislocation may require operative intervention. The type of surgical procedure depends on intraoperative findings: sural nerve grafting in cases of neural elements' disruption, internal neurolysis when intraneural fibrosis is observed, and external neurolysis in the remaining cases. The outcomes of surgical treatment are good, and the risk of intra- and postoperative complications is low. Copyright © 2017 Elsevier Inc. All rights reserved.
Yeung, Marco; Memon, Muzammil; Simunovic, Nicole; Belzile, Etienne; Philippon, Marc J; Ayeni, Olufemi R
2016-06-01
Gross hip instability is a rare complication after hip arthroscopy, and there is limited literature surrounding this topic. This systematic review investigates cases of gross hip instability after arthroscopy and discusses the risk factors associated with this complication. A systematic search was performed in duplicate for studies investigating gross hip instability after hip arthroscopy up to October 2015. Study parameters including sample size, mechanism and type of dislocation, surgical procedure details, patient characteristics, postoperative rehabilitation protocol, and level of evidence were analyzed. The systematic review identified 9 case reports investigating gross hip instability after hip arthroscopy (10 patients). Anterior dislocation occurred in 66.7% of patients, and most injuries occurred with a low-energy mechanism. Common surgical factors cited included unrepaired capsulotomy (77.8%) and iliopsoas release (33.3%), whereas patient factors included female gender (77.8%), acetabular dysplasia (22.2%), and general ligamentous laxity (11.1%). Postoperative restrictions and protocols were variable and inconsistently reported, and their relation to post-arthroscopy instability was difficult to ascertain. This systematic review discussed various patient, surgical, and postoperative risk factors of gross hip instability after arthroscopy. Patient characteristics such as female gender, hip dysplasia, and ligamentous laxity may be risk factors for post-arthroscopy dislocation. Similarly, surgical risk factors for iatrogenic hip instability may include unrepaired capsulotomies and iliopsoas debridement, although the role of capsular closure in iatrogenic instability is not clear. The influences of postoperative restrictions and protocols on dislocation are also unclear in the current literature. Surgeons should be cognizant of these risk factors when performing hip arthroscopy and be mindful that these factors appear to occur in combination. Level IV, systematic review of Level IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
White, L; Holyoak, R; Sant, J; Hartnell, N; Mullan, J
2016-05-01
The infrapatellar fat pad (IPFP) is resected in approximately 88 % of total knee arthroplasty (TKA) surgeries. The aim of this review is to investigate the impact of the IPFP resection on clinical outcomes post-TKA. A systematic search of five major databases for all relevant articles published until May, 2015 was conducted. Studies comparing the effect of IPFP resection and preservation on outcomes post-TKA were included. Each study was then assessed individually for level of evidence and risk of bias. Studies were then grouped into post-operative outcomes and given a level of evidence ranking based on the collective strength of evidence. The systematic review identified ten studies suitable for inclusion, with a total of 10,163 patients. Within these ten studies, six post-operative outcomes were identified; knee pain, vascularisation of the patella, range of motion (ROM), patella tendon length/patella infera, wound complications and patient satisfaction. Moderate evidence increased knee pain with IPFP resection post-TKA was found. Conflicting evidence was found for patella vascularisation and patellar tendon length post-TKA. Moderate evidence for no difference in ROM was found. One low quality study was found for wound complications and patient satisfaction. This systematic review is limited by the lack of level one randomised controlled trials (RCTs). There is however moderate level evidence that IPFP resection increases post-operative knee pain. Further level one RCTs are required to produce evidence-based guidelines regarding IPFP resection. Systematic Review Level of Evidence: 3.
Vivod, Gregor; Verdonk, Peter; Drobnič, Matej
2014-11-01
A retrospective single-centre study was focused on the long-term outcome after different patello-femoral (PF) realignment procedures. Thirty-nine patients treated for recurrent PF instability were examined after a mean post-operative time of 22.5 years. Their 78 knees were divided into: non-operated knees (NON-OPERATED)-N = 24, isolated proximal procedures (PROXIMAL)-N = 22, isolated distal procedures (DISTAL)-N = 10, and combined procedures (COMBINED)-N = 22. PF-related medical history together with clinical, subjective (KOOS and Kujala scores), and radiographic (Caton-Deschamps PF height index, Kellgren-Lawrence scale for tibio-femoral OA, and Iwano classification for PF OA) evaluation was conducted. PF re-dislocation rate was comparable between PROXIMAL (36%), DISTAL (20%), and COMBINED (32%). Isolated proximal procedures revealed less central patella positions (PROXIMAL 64%; DISTAL 90%; COMBINED 95%) and more frequent PF apprehension test (PROXIMAL 82%; DISTAL 40%, COMBINED 50%). KOOS and Kujala scores were similar in all three surgical subgroups, but significantly lower than in NON-OPERATED. Patellas were positioned lower after DISTAL, 0.8 (0.5-1.0) or COMBINED, 0.9 (0.4-1.3). Kellgren-Lawrence scores ≥2 were found in 42% NON-OPERATED, 37% PROXIMAL, 70% DISTAL, and 59% COMBINED, whereas Iwano classification ≥2 was confirmed in 46% NON-OPERATED, 64% PROXIMAL, 80% DISTAL, and 86% COMBINED. High PF re-dislocation rates together with a very high incidence of PF OA indicate that PF realignment strategies used traditionally had failed to reach their long-term expectations. The transfer of tibial tuberosity resulted in more constrained PF joints than isolated proximal procedures which allowed for more residual PF instability. Distal procedures additionally increased the likelihood for tibio-femoral OA. III.
Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H
2017-06-01
This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.
Geeslin, Andrew G; Moulton, Samuel G; LaPrade, Robert F
2016-05-01
There is a paucity of outcome data to guide the surgical treatment of acute grade III posterolateral corner (PLC) knee injuries. To systematically review the literature to compare clinical outcomes of the treatment for acute grade III PLC injuries. Systematic review; Level of evidence, 4. A systematic review of the literature including Cochrane, PubMed, Medline, and Embase was performed. The following search terms were used: posterolateral corner knee, posterolateral knee, posterolateral instability, multiligament knee, and knee dislocation. Inclusion criteria were outcome studies of surgically treated acute PLC injuries with a minimum 2-year follow-up, subjective outcomes, objective outcomes including varus stability, and subgroup data on PLC injuries. Two investigators independently reviewed all abstracts. Accepted definitions of varus stability on examination or stress radiographs and the need for revision surgery were used to categorically define success and failure. Eight studies with a total of 134 patients were included. The mean patient age was reported in 7 studies (range, 21-31.5 years). The mean time to surgery was reported in 5 studies (range, 15-24.3 days); surgery was performed within 3 weeks in the other 3 studies. Four studies reported International Knee Documentation Committee scores (range, 78.1-91.3); 5 studies reported Lysholm scores (range, 87.5-90.3). Only 3 studies obtained bilateral varus stress radiographs. Based on an objective evaluation with varus stress examinations or radiographs, there was an overall success rate of 81% and failure rate of 19%. In 2 studies, the fibular collateral ligament and popliteus tendon were repaired and staged cruciate reconstruction performed in most patients; there were 17 failures of 45 patients (38%). In the remainder of the studies, patients were treated with local tissue transfer, hybrid repair for amenable structures or reconstruction for midsubstance tears, or reconstruction of all torn structures; the failure rate was 9%. The repair of acute grade III PLC injuries and staged treatment of combined cruciate injuries were associated with a substantially higher postoperative PLC failure rate. Further research is required to identify the reconstruction technique that provides optimal subjective and objective outcomes. © 2015 The Author(s).
Comparison of four different reduction methods for anterior dislocation of the shoulder.
Guler, Olcay; Ekinci, Safak; Akyildiz, Faruk; Tirmik, Uzeyir; Cakmak, Selami; Ugras, Akin; Piskin, Ahmet; Mahirogullari, Mahir
2015-05-28
Shoulder dislocations account for almost 50% of all major joint dislocations and are mainly anterior. The aim is a comparative retrospective study of different reduction maneuvers without anesthesia to reduce the dislocated shoulder. Patients were treated with different reduction maneuvers, including various forms of traction and external rotation, in the emergency departments of four training hospitals between 2009 and 2012. Each of the four hospitals had different treatment protocols for reduction and applying one of four maneuvers: Spaso, Chair, Kocher, and Matsen methods. Thirty-nine patients were treated by the Spaso method, 47 by the Chair reduction method, 40 by the Kocher method, and 27 patients by Matsen's traction-countertraction method. All patients' demographic data were recorded. Dislocation number, reduction time, time interval between dislocation and reduction, and associated complications, pre- and post-reduction period, were recorded prospectively. No anesthetic method was used for the reduction. All of the methods used included traction and some external rotation. The Chair method had the shortest reduction time. All surgeons involved in the study agreed that the Kocher and Matsen methods needed more force for the reduction. Patients could contract their muscles because of the pain in these two methods. The Spaso method includes flexion of the shoulder and blocks muscle contraction somewhat. The Chair method was found to be the easiest because the patients could not contract their muscles while sitting on a chair with the affected arm at their side. We suggest that the Chair method is an effective and fast reduction maneuver that may be an alternative for the treatment of anterior shoulder dislocations. Further prospective studies with larger sample size are needed to compare safety of different reduction techniques.
Mixed-mode singularity and temperature effects on dislocation nucleation in strained interconnects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Jinhaeng; Gao, Yanfei
2011-01-01
Dislocations can be nucleated from sharp geometric features in strained interconnects due to thermal expansion coefficient mismatch, lattice mismatch, or stresses that arise during material processing. The asymptotic stress fields near the edge root can be described by mixed-mode singularities, which depend on the dihedral angle and material properties, and a transverse T-stress, which depends on how residual stress is realized in the interconnects. The critical condition for stress nucleation can be determined when an appropriate measure of the stress intensity factors (SIFs) reaches a critical value. Such a method, however, does not offer an explicit picture of the dislocationmore » nucleation process so that it has difficulties in studying complicated structures, mode mixity effects, and more importantly the temperature effects. Based on the Peierls concept, a dislocation can be described by a continuous slip field, and the dislocation nucleation condition corresponds when the total potential energy reaches a stationary state. Through implementing this ad hoc interface model into a finite element framework, it is found that dislocation nucleation becomes more difficult with the increase of mode mixity and T-stress, or the decrease of the width-to-height ratio of the surface pad, while the shape of the surface pad, being a square or a long line, plays a less important role. The Peierls dislocation model also allows us to determine the activation energy, which is the energy needed for the thermal activation of a dislocation when the applied load is lower than the athermal critical value. The calculated saddle point configuration compares favorably the molecular simulations in literature. Suggestions on making immortal strained interconnects are provided.« less
Abdel-Aziz, Ahmed; Radwan, Yasser A; Rizk, Ahmed
2014-01-01
This study was undertaken to prospectively analyse, at a mean five-year follow-up, the clinical, functional, and radiographic outcomes in patients who developed postoperative acute septic knee arthritis following anterior cruciate ligament (ACL) reconstruction using hamstring autograft. We also assessed the effect of multiple arthroscopic debridement and graft retention on the functional outcomes in comparison with the matched control group. From a consecutive case series of 2,560 ACL-injured patients who were treated with arthroscopic ACL reconstruction, we report on 24 cases with postoperative septic knee arthritis. These patients were individually matched for age, sex, comorbidity, body mass index (BMI) and preinjury Tegner activity scale in a ratio of 1/1. Clinical, laboratory, synovial fluid analysis and culture were performed. Arthroscopic debridement and graft retention was done for all cases, in addition to antibiotic therapy i.v.. A detailed physical examination, KT1000 laxity testing, Lysholm knee score, Tegner activity level scale, International Knee Documentation Committee (IKDC), and Knee Injury and Osteoarthritis Outcome Score (KOOS) were completed. In all cases, treatment of infection was successful after a median of three (range one to six) repeated arthroscopic graft debridement and retention, in addition to antibiotic therapy i.v.. At an average of five years follow-up, two patients had over five millimetres manual maximum side-to-side difference in laxity. There were no significant differences between groups regarding Lysholm score, IKDC and KOOS. Median final Tegner activity score was 5.5 versus 7 in the control group (p = 0.004). Complications included graft rupture in three patients, loss of range of motion in five, Sudeck's atrophy in one and moderate joint narrowing in two. There were no recurrences of septic arthritis or bone infection. Graft retention seems not only possible but appropriate in view of the experience presented in this article for postoperative septic knee arthritis using hamstring autograft. A potential residual complication is arthrofibrosis, which deserves maximum attention.
Tibial stress fracture after computer-navigated total knee arthroplasty.
Massai, F; Conteduca, F; Vadalà, A; Iorio, R; Basiglini, L; Ferretti, A
2010-06-01
A correct alignment of the tibial and femoral component is one of the most important factors determining favourable long-term results of a total knee arthroplasty (TKA). The accuracy provided by the use of the computer navigation systems has been widely described in the literature so that their use has become increasingly popular in recent years; however, unpredictable complications, such as displaced or stress femoral or tibial fractures, have been reported to occur a few weeks after the operation. We present a case of a stress tibial fracture that occurred after a TKA performed with the use of a computer navigation system. The stress fracture, which eventually healed without further complications, occurred at one of the pinhole sites used for the placement of the tibial trackers.
Acute common peroneal neuropathy due to hand positioning in normal labor and delivery.
Radawski, Melissa M; Strakowski, Jeffrey A; Johnson, Ernest W
2011-08-01
Foot drop has been described as an infrequent complication from common peroneal nerve injury related to external compression and forceful knee flexion while pushing during vaginal delivery. Past recommendations include placing the hands at the posterior thighs rather than the legs to avoid this complication. A 32-year-old woman developed unilateral foot drop after vaginal delivery. Electromyography was diagnostic for an acute compression neuropathy of the common peroneal nerve above the knee. The patient's likely mechanism of injury occurred during delivery from external compression by the patient's dominant hand to the distal posterior thigh while under epidural anesthesia. Labor and delivery teams should be aware that nerve injury is also possible at the distal thigh with excessive external pressure.
Mönig, S P; Burger, C; Helling, H J; Prokop, A; Rehm, K E
1999-11-01
We report a retrospective study of 48 patients with complete acromioclavicular dislocation (Tossy III). All patients (38 male; 10 female) with an average age of 33.4 years underwent surgery including PDS-augmentation. More than half of the injuries were caused by sport accidents. There were no complications during surgery. 87% of the patients were free of complaints and subjectively very satisfied with the surgical results. By radiological examination we diagnosed a subluxation of the clavicula in 25% of the cases and arthrosis in 17% of the cases. Assessment of subjective complaints, the clinical examination, and the radiological diagnostic according to the Taft Score (0-12 points) resulted in an average value of 10.2 points. The surgical intervention using PDS-cord augmentation in cases of complete acromioclavicular separation is a safe and economic method with a low complication rate. Advantages are possible early-functional treatment, no risk of movement of implants, and avoidance of metal removal.
PERIPROSTHETIC FRACTURES IN TOTAL KNEE ARTHROPLASTY
de Alencar, Paulo Gilberto Cimbalista; De Bortoli, Giovani; Ventura Vieira, Inácio Facó; Uliana, Christiano Saliba
2015-01-01
The increasing number of total knee arthroplasties, in combination with the population's longer life expectancy, has led to a greater number of long-term complications. These add to the poor bone quality of elderly patients and often culminate in periprosthetic fractures. This complex orthopedic problem has a great diversity of clinical presentation. It may affect any of the bones in the knee and, because of the difficulty in finding solutions, may lead to disastrous outcomes. Its treatment requires that orthopedists should have broad knowledge both of arthroplasty techniques and of osteosynthesis, as well as an elaborate therapeutic arsenal including, for example, access to a bone bank. PMID:27022546
Jansen, Joris A; Lameijer, Joost R C; Snoeker, Barbara A M
2017-10-01
The aims of this study were to investigate the safety of combined intravenous, oral and topical tranexamic acid (TXA) in primary total knee replacement. We assessed dose-related efficacy on hemoglobin level, transfusion, length of stay and thromboembolic complications. In addition, TXA safety in patients with previous history of thromboembolism >12months ago was monitored specifically. From January 2013 until January 2016, 922 patients were included who received TXA after primary total knee replacement. Patients without TXA administration or with thromboembolic events <12months ago were excluded. TXA dosage groups were divided into ≤10mg/kg, >10-25mg/kg and >25-50mg/kg. Between the three TXA groups no significant difference was found in thromboembolic complications (deep venous thrombosis (DVT) and pulmonary embolism (PE)), wound leakage and transfusion rate. For patients with DVT or PE in their history >12months ago specifically, no more complications were noted in higher-TXA-dosage groups compared to the low-dosage group. Length of stay was shorter in the highest-TXA-dosage group compared with lower-dosage groups (median two vs three days). With high TXA dose a smaller difference between pre- and postoperative Hb was found: the >25-50mg/kg TXA group had a 0.419mmol/l smaller decrease in postoperative hemoglobin compared to the lowest-dosage group (P<0.05). Combined intravenous, oral and topical TXA is effective in knee replacement and can safely be given to patients with a thromboembolic history >12months ago. High dosage (>25-50mg/kg) TXA resulted in the smallest decrease in postoperative hemoglobin. Copyright © 2017 Elsevier B.V. All rights reserved.
Maradit-Kremers, Hilal; Haque, Omar J; Kremers, Walter K; Berry, Daniel J; Lewallen, David G; Trousdale, Robert T; Sierra, Rafael J
2017-04-01
To resurface or not to resurface the patella remains a controversy in total knee arthroplasty (TKA). The purpose of this study was to assess the long-term outcomes associated with selectively not resurfacing the patella. This was a historical cohort study of 15,497 patients with 21,371 primary TKA procedures performed at a single institution between 1985 and 2010. The cohort included 402 (2%) knees with unresurfaced patellae and 20,969 knees with all-polyethylene patellae designs. Reasons for not resurfacing the patella were documented. Multivariable Cox regression analyses were used to estimate the risk of complications and revisions among procedures with unresurfaced patellae. According to the surgeon, reasons for not resurfacing were normal cartilage (226, 56%), young patient (30, 8%), thin patella (53, 13%), and surgeons' choice (93, 23%). In age, sex, and calendar year-adjusted analyses, the risk of complications (hazard ratio [HR]: 1.25, 95% confidence interval [CI]: 1.06, 1.46) and all-cause revisions (HR: 1.39, 95% CI: 1.02, 1.89) were significantly higher after TKA with unresurfaced patellae. However, after adjusting for femoral component types and operative diagnoses, these associations were no longer significant. The only group with significantly worse outcomes were those with a thin patellae with increased risk of complications (HR: 2.66, 95% CI: 1.70, 4.17) and revisions (HR: 5.94, 95% CI: 2.35, 15.02). Yet, the excess risk in the thin patellae group was mainly due to infections, and not related to unresurfaced patellae. Selectively not resurfacing the patella seemed to provide similar results compared with routine resurfacing. Copyright © 2016 Elsevier Inc. All rights reserved.
Moulton, Samuel G; Geeslin, Andrew G; LaPrade, Robert F
2016-06-01
There are a variety of reported surgical techniques outcomes of chronic grade III posterolateral corner (PLC) knee injuries. It is unknown if outcomes differ among the various surgical treatments. To systematically review the literature and report subjective and objective outcomes for surgical treatment strategies for chronic grade III PLC injuries to determine the optimal surgical technique. Systematic review; Level of evidence, 4. A systematic review of the literature including Cochrane, PubMed, Medline, and Embase was performed. The following search terms were used: posterolateral corner knee, posterolateral knee, posterolateral instability, multiligament knee, and knee dislocation. Inclusion criteria were outcome studies of surgical treatment for chronic PLC knee injuries with a minimum 2-year follow-up, subjective outcomes, objective outcomes including varus stability, and subgroup data on PLC injuries. Two investigators independently reviewed all abstracts. Accepted definitions of varus stability on examination or stress radiographs, and the need for revision surgery, were used to categorically define success and failure. Fifteen studies with a total of 456 patients were included in this study. The 15 studies included 5 with level 3 evidence and 10 with level 4 evidence. The mean age of the patients in each study ranged from 25.2 to 40 years, the reported mean time to surgery ranged from 5.5 to 52.8 months, and the mean follow-up duration ranged from 2 to 16.3 years. Mean postoperative Lysholm scores ranged from 65.5 to 91.8; mean postoperative International Knee Documentation Committee (IKDC) scores ranged from 62.6 to 86.0. Based on objective stability, there was an overall success rate of 90% and a 10% failure rate of PLC reconstruction. A variety of surgical techniques were reported. Chronic PLC injuries were reconstructed in all studies, and while techniques varied, the surgical management of chronic PLC injuries had a 90% success rate and a 10% failure rate according to the individual investigators' examination or stress radiographic assessment of objective outcomes. More than half of the 456 patients had a combined posterior cruciate ligament-PLC injury. Surgical techniques included variations of fibular slings, capsular shifts, and anatomic-based techniques (fibular tunnel and tibial tunnel). Further research is needed to determine the optimal surgical technique for treating chronic grade III PLC injuries. © 2015 The Author(s).
Cerebral fat embolism after bilateral total knee replacement arthroplasty -A case report-
Chang, Ri-Na; Lee, Heeseung; Baik, Hee-Jung; Chung, Rack Kyung; Kim, Chi Hyo; Hwang, Tae-Hu
2010-01-01
Fat embolism syndrome is a rare and potentially lethal complication most commonly seen in long bone fractures and intramedullary manipulation. The clinical triad of fat embolism syndrome consists of mental confusion, respiratory distress, and petechiae. This study reports a case of cerebral fat embolism syndrome following elective bilateral total knee replacement. After an uneventful anesthesia and initial recovery, the patient developed neurologic symptoms nine hours postoperatively. PMID:21286442
Buchbinder, Rachelle; Richards, Bethan; Harris, Ian
2014-03-01
Over the last decade, there has been increased recognition of the importance of high-quality randomized controlled trials in determining the role of surgery for knee osteoarthritis. This review highlights key findings from the best available studies, and considers whether or not this knowledge has resulted in better evidence-based care. Use of arthroscopy to treat knee osteoarthritis has not declined despite strong evidence-based recommendations that do not sanction its use. A large randomized controlled trial has demonstrated that arthroscopic partial meniscectomy followed by a standardized physical therapy program results in similar improvements in pain and function at 6 and 12 months in comparison to physical therapy alone in patients with knee osteoarthritis and a symptomatic meniscal tear, confirming the findings of two previous trials. Two recent randomized controlled trials have demonstrated that decision aids help people to reach better-informed decisions about total knee arthroplasty. A majority of studies have indicated that for people with obesity the positive results of total knee arthroplasty may be compromised by postoperative complications, particularly infection. More efforts are needed to overcome significant evidence-practice gaps in the surgical management of knee osteoarthritis, particularly arthroscopy. Decision aids are a promising tool.
Schröder, Christian; Steinbrück, Arnd; Müller, Tatjana; Woiczinski, Matthias; Chevalier, Yan; Müller, Peter E.; Jansson, Volkmar
2015-01-01
Retropatellar complications after total knee arthroplasty (TKA) such as anterior knee pain and subluxations might be related to altered patellofemoral biomechanics, in particular to trochlear design and femorotibial joint positioning. A method was developed to test femorotibial and patellofemoral joint modifications separately with 3D-rapid prototyped components for in vitro tests, but material differences may further influence results. This pilot study aims at validating the use of prostheses made of photopolymerized rapid prototype material (RPM) by measuring the sliding friction with a ring-on-disc setup as well as knee kinematics and retropatellar pressure on a knee rig. Cobalt-chromium alloy (standard prosthesis material, SPM) prostheses served as validation standard. Friction coefficients between these materials and polytetrafluoroethylene (PTFE) were additionally tested as this latter material is commonly used to protect pressure sensors in experiments. No statistical differences were found between friction coefficients of both materials to PTFE. UHMWPE shows higher friction coefficient at low axial loads for RPM, a difference that disappears at higher load. No measurable statistical differences were found in knee kinematics and retropatellar pressure distribution. This suggests that using polymer prototypes may be a valid alternative to original components for in vitro TKA studies and future investigations on knee biomechanics. PMID:25879019
Weight-training injuries. Common injuries and preventative methods.
Mazur, L J; Yetman, R J; Risser, W L
1993-07-01
The use of weights is an increasingly popular conditioning technique, competitive sport and recreational activity among children, adolescents and young adults. Weight-training can cause significant musculoskeletal injuries such as fractures, dislocations, spondylolysis, spondylolisthesis, intervertebral disk herniation, and meniscal injuries of the knee. Although injuries can occur during the use of weight machines, most apparently happen during the aggressive use of free weights. Prepubescent and older athletes who are well trained and supervised appear to have low injury rates in strength training programmes. Good coaching and proper weightlifting techniques and other injury prevention methods are likely to minimise the number of musculoskeletal problems caused by weight-training.
Scattering of phonons by dislocations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, A. C.
1979-01-01
By 1950, an explicit effort had been launched to use lattice thermal conductivity measurements in the investigation of defect structures in solids. This technique has been highly successful, especially when combined with the measurements of other properties such as optical absorption. One exception has been the study of dislocations. Although dislocations have a profound effect on the phonon thermal conductivity, the mechanisms of the phonon-dislocation interaction are poorly understood. The most basic questions are still debated in the literature. It therefore is pointless to attempt a quantitative comparison between an extensive accumulation of experimental data on the one hand, andmore » the numerous theoretical models on the other. Instead, this chapter will attempt to glean a few qualitative conclusions from the existing experimental data. These results will then be compared with two general models which incorporate, in a qualitative manner, most of the proposed theories of the phonon-dislocation interaction. Until very recently, measurement of thermal conductivity was the only means available to probe the interaction between phonons and defects at phonon frequencies above the standard ultrasonic range of approx. = 10/sup 9/ Hz. The introductory paragraphs provide a brief review of the thermal-conductivity technique and the problems which are encountered in practice. There is also a brief presentation of the theoretical models and the complications that may occur in more realistic situations.« less
Tresley, Jonathan; Jose, Jean
2015-04-01
Osteoarthritis of the knee can be a debilitating and extremely painful condition. In patients who desire to postpone knee arthroplasty or in those who are not surgical candidates, percutaneous knee injection therapies have the potential to reduce pain and swelling, maintain joint mobility, and minimize disability. Published studies cite poor accuracy of intra-articular knee joint injections without imaging guidance. We present a sonographically guided posteromedial approach to intra-articular knee joint injections with 100% accuracy and no complications in a consecutive series of 67 patients undergoing subsequent computed tomographic or magnetic resonance arthrography. Although many other standard approaches are available, a posteromedial intra-articular technique is particularly useful in patients with a large body habitus and theoretically allows for simultaneous aspiration of Baker cysts with a single sterile preparation and without changing the patient's position. The posteromedial technique described in this paper is not compared or deemed superior to other standard approaches but, rather, is presented as a potentially safe and efficient alternative. © 2015 by the American Institute of Ultrasound in Medicine.
[Periprosthetic knee fractures].
Mittlmeier, T; Beck, M; Bosch, U; Wichelhaus, A
2016-01-01
The cumulative incidence of periprosthetic fractures around the knee is increasing further because of an extended indication for knee replacement, previous revision arthroplasty, rising life expectancy and comorbidities. The relevance of local parameters such as malalignment, osseous defects, neighbouring implants, aseptic loosening and low-grade infections may sometimes be hidden behind the manifestation of a traumatic fracture. A differentiated diagnostic approach before the treatment of a periprosthetic fracture is of paramount importance, while the physician in-charge should also have particular expertise in fracture treatment and in advanced techniques of revision endoprosthetics. The following work gives an overview of this topic. Valid classifications are available for categorising periprosthetic fractures of the femur, the tibia and the patella respectively, which are helpful for the selection of treatment. With the wide-ranging modern treatment portfolio bearing in mind the substantial rate of complications and the heterogeneous functional outcome, the adequate analysis of fracture aetiology and the corresponding transformation into an individualised treatment concept offer the chance of an acceptable functional restoration of the patient at early full weight-bearing and prolonged implant survival. The management of complications is crucial to the final outcome.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goltz, Jan P., E-mail: Goltz@roentgen.uni-wuerzburg.de; Scholl, Anne; Ritter, Christian O.
The aim of this study is to evaluate the effectiveness and safety of percutaneously placed totally implantable venous-access ports (TIVAPs) of the forearm. Between January 2006 and October 2008, peripheral TIVAPs were implanted in 763 consecutive patients by ultrasound and fluoroscopic guidance. All catheters were implanted under local anesthesia and were tunneled subcutaneously. Indication, technical success, and complications were retrospectively analyzed according to Society of Interventional Radiology (SIR) criteria. Presence of antibiotic prophylaxis, periprocedurally administered drugs (e.g., sedation), and laboratory results at the time of implantation were analyzed. Maintenance during the service interval was evaluated. In total, 327,499 catheter-days weremore » analyzed. Technical success rate was 99.3%. Reasons for initial failure of implantation were either unexpected thrombosis of the subclavian vein, expanding tumor mass of the mediastinum, or failure of peripheral venous access due to fragile vessels. Mean follow-up was 430 days. There were 115 complications observed (15.1%, 0.03 per 100 catheter-days), of which 33 (4.3%) were classified as early (within 30 days from implantation) and 82 (10.7%) as late. Catheter-related venous thrombosis was found in 65 (8.5%) of 763 (0.02 per 100 catheter-days) TIVAPs. Infections were observed in 41 (5.4%) of 763 (0.01 per 100 catheter-days) devices. Other complications observed included dislocation of the catheter tip (0.8%), occlusion (0.1%), or rupture (0.1%) of the port catheter. Dislocated catheters were corrected during a second interventional procedure. In conclusion, implantation of percutaneously placed peripheral TIVAPs shows a high technical success rate and low risk of early complications when ultrasound and fluoroscopic guidance are used. Late complications are observed three times as often as early complications.« less
Kassem Abdelaal, Ahmed Hamed; Yamamoto, Norio; Hayashi, Katsuhiro; Takeuchi, Akihiko; Miwa, Shinji; Inatani, Hiroyuki; Tsuchiya, Hiroyuki
2015-01-01
Introduction. The main indication for knee arthrodesis in tumor surgery is a tumor that requires an extensive resection in which the joint surface cannot be preserved. We report a patient that had knee desarthrodesis 41 years after giant cell tumor resection followed by a knee arthrodesis. This is the longest reported follow-up after desarthrodesis and conversion to total knee arthroplasty (TKA), almost ten years. Case Report. A 71-year-old man with a distal femoral giant cell tumor had undergone a resection of the distal femur and knee arthrodesis using Kuntscher nail in 1962. In July 2003 he experienced gradually increasing pain of his left knee. We performed a desarthrodesis and conversion to TKA in 2005. The postoperative period passed uneventfully as his pain and gait improved, with gradually increasing range of motion (ROM) and no infection. He now walks independently, with no brace or contractures. Conclusion. Desarthrodesis of the knee joint and conversion to TKA are a difficult surgical choice with a high complication risk. However, our patient's life style has improved, he has no pain, and he can ascend and descend stairs more easily. The surgeon has to be very meticulous in selecting a patient for knee arthrodesis and counseling them to realize that their expectations may not be achievable. PMID:26688766
Kassem Abdelaal, Ahmed Hamed; Yamamoto, Norio; Hayashi, Katsuhiro; Takeuchi, Akihiko; Miwa, Shinji; Inatani, Hiroyuki; Tsuchiya, Hiroyuki
2015-01-01
Introduction. The main indication for knee arthrodesis in tumor surgery is a tumor that requires an extensive resection in which the joint surface cannot be preserved. We report a patient that had knee desarthrodesis 41 years after giant cell tumor resection followed by a knee arthrodesis. This is the longest reported follow-up after desarthrodesis and conversion to total knee arthroplasty (TKA), almost ten years. Case Report. A 71-year-old man with a distal femoral giant cell tumor had undergone a resection of the distal femur and knee arthrodesis using Kuntscher nail in 1962. In July 2003 he experienced gradually increasing pain of his left knee. We performed a desarthrodesis and conversion to TKA in 2005. The postoperative period passed uneventfully as his pain and gait improved, with gradually increasing range of motion (ROM) and no infection. He now walks independently, with no brace or contractures. Conclusion. Desarthrodesis of the knee joint and conversion to TKA are a difficult surgical choice with a high complication risk. However, our patient's life style has improved, he has no pain, and he can ascend and descend stairs more easily. The surgeon has to be very meticulous in selecting a patient for knee arthrodesis and counseling them to realize that their expectations may not be achievable.
Lyu, J; Zhao, P-q
2016-01-01
Purpose We report a simplified ab externo scleral fixation technique to manage the late dislocation of scleral-sutured polymethyl methacrylate (PMMA) intraocular lenses (IOLs) in the absence of capsule support. Materials and methods The technique was performed on five eyes of five patients. Symmetrical scleral pocket tunnels without conjunctival peritomy were created. An anterior vitrectomy via a limbal approach with an anterior chamber infusion or a 3-port pars plana vitrectomy was performed to rescue the dislocated IOL. A long straight suture needle and 23-gauge vitreoretinal forceps were used to conveniently reposition the IOL and loop sutures through the IOL positioning eyelets without externalizing IOL haptics. The outside suture knots were buried under the roof of the scleral tunnels. Results The patients were followed for 5–14 months after surgery. All the operated eyes quickly recovered with negligible corneal endothelial cell loss and mild inflammation. Visual acuity improvement and IOL centration were achieved in all eyes with no major complications. Conclusion The simplified ab externo scleral fixation technique offers an effective and minimally invasive surgical alternative to salvage dislocated previously scleral-sutured PMMA IOLs. PMID:26795420
Lyu, J; Zhao, P-Q
2016-05-01
PurposeWe report a simplified ab externo scleral fixation technique to manage the late dislocation of scleral-sutured polymethyl methacrylate (PMMA) intraocular lenses (IOLs) in the absence of capsule support.Materials and methodsThe technique was performed on five eyes of five patients. Symmetrical scleral pocket tunnels without conjunctival peritomy were created. An anterior vitrectomy via a limbal approach with an anterior chamber infusion or a 3-port pars plana vitrectomy was performed to rescue the dislocated IOL. A long straight suture needle and 23-gauge vitreoretinal forceps were used to conveniently reposition the IOL and loop sutures through the IOL positioning eyelets without externalizing IOL haptics. The outside suture knots were buried under the roof of the scleral tunnels.ResultsThe patients were followed for 5-14 months after surgery. All the operated eyes quickly recovered with negligible corneal endothelial cell loss and mild inflammation. Visual acuity improvement and IOL centration were achieved in all eyes with no major complications.ConclusionThe simplified ab externo scleral fixation technique offers an effective and minimally invasive surgical alternative to salvage dislocated previously scleral-sutured PMMA IOLs.
Lin, Kenneth M; James, Evan W; Spitzer, Elad; Fabricant, Peter D
2018-02-01
The purpose of this review is to discuss the epidemiology, pathoanatomy, diagnosis, and clinical management of pediatric and adolescent patients following a first-time shoulder dislocation. Shoulder instability is becoming increasingly common as pediatric and adolescent patients engage in earlier organized sports competition. Recommended treatment following a first-time glenohumeral dislocation event in adolescents depends on several factors, but surgical stabilization is becoming more frequently performed. Surgical indications include bony Bankart lesion, ALPSA lesion, bipolar injury (e.g. Hill-Sachs humeral head depression fracture) or off-season injury in an overhead or throwing athlete. Complications following surgical treatment are rare but most commonly are associated with recurrent instability. Young children (eg. open proximal humerus growth plate), individuals averse to surgery, or in-season athletes who accept the risk of redislocation may complete an accelerated rehabilitation program for expedited return to play in the absence of the structural abnormalities listed above. Following a first-time dislocation event in pediatric and adolescent patients, a detailed discussion of the risks and benefits of nonoperative versus operative management is critical to match the recommended treatment with the patient's injury pattern, risk factors, and activity goals.
Distal femoral osteotomy in genovalgum: internal fixation with blade plate versus casting.
Makhmalbaf, Hadi; Moradi, Ali; Ganji, Saeid
2014-10-01
To compare the results of two different ways of distal femoral osteotomy stabilization in patients suffering from genuvalgum: internal fixation with plate, and casting. In a non-randomized prospective study, after distal femoral osteotomy with the zigzag method, patients were divided into two groups: long leg casting, and internal fixation with blade plate. For all patients, questionnaires were filled to obtain data. Information such as range of motion, tibiofemoral anatomical angle and complications were recorded. 38 knees with valgus deformity underwent distal femoral supracondylar osteotomy. (8 with plaster cast and 30 with internal fixation using a blade plate). Preoperative range of motion was 129±6° and six months later it was 120±14°. The preoperative tibiofemoral angle was 32±6°; postoperative tibiofemoral angles were 3±3°, 6±2°, and 7±3° just after operation, six months, and two years later, respectively. Although this angle was greater among the group stabilized with a cast, this difference was not statistically significant. In postoperative complications, over-correction was found in five, recorvatom deformity in one, knee stiffness in three and superficial wound infection was recorded in three knees. There is no prominent difference in final range of motion and alignment whether fixation is done with casting or internal fixation. However, the complication rate seems higher in the casting method.
Razii, Nima; Abbas, Ammar M I; Kakar, Rahul; Agarwal, Sanjeev; Morgan-Jones, Rhidian
2016-12-01
Periprosthetic infection following total knee arthroplasty is a devastating complication, which is not always satisfactorily resolved by revision surgery. Arthrodesis is a salvage alternative to above-knee amputation or permanent resection arthroplasty. Fixation options include internal compression plating, external fixation, and intramedullary nails. We retrospectively reviewed twelve consecutive cases (9 males, 3 females; mean age, 67 years) of knee arthrodesis with a long intramedullary nail, performed at a single institution between 2003 and 2014. Desired outcomes were the ability to mobilize without pain, solid radiographic fusion, and the eradication of infection. Mean follow-up was 48.5 months (range, 9-120 months). Eleven patients (92 %) demonstrated stable fusion, ten patients (83 %) were ambulatory without pain, and ten patients (83 %) remained without infection at most recent follow-up. Eight patients (67 %) achieved union at an average of 12 months; three required repeat procedures, achieving union at an average of 9 months. There was a significant difference (P < 0.01) between the numbers of previous operations amongst the eight patients who initially achieved union (mean, 3.25) and three who subsequently required repeat procedures (mean, 8.33). In contrast to similar studies, we performed a single-stage exchange where possible, while comparable ambulatory and fusion rates were observed. Numerous previous attempts at revision arthroplasty, co-morbidities, and infections with highly resistant organisms have been associated with further complications. Although technically challenging, knee arthrodesis with a long intramedullary nail offers an acceptable limb salvage procedure for carefully selected patients with complex periprosthetic infections.
Lameijer, Joost R C; Verboom, Frederik; Grefkens, Joost; Jansen, Joris
2016-10-01
Local infiltration analgesia (LIA) during total knee arthroplasty has been shown to give statistically significant reduction in post-operative pain. The effects of using high volumes of ropivacaine combined with adrenaline as LIA on cardiovascular parameters in knee replacement have not been described before. The objective of this study was to investigate the cardiovascular safety of ropivacaine as part of high volume local infiltration analgesia (LIA) in total knee replacement surgery. This is a retrospective observational comparative cohort study conducted in two independent cohorts, one treated without and one treated with a local infiltration analgesia protocol, containing a total of 744 patients with a mean age of 68years (42 to 89) and 68years (21 to 88) respectively with a follow-up of 12months. No statistical difference in bradycardia during surgery, post-operative cardiovascular complications, and mortality was found after use of LIA. A statistically significant lower incidence of hypotension was found in the LIA group (P<0.01). This result has to be interpreted with care, due to the use of adrenaline in the LIA mixture, which could mask possible hypotension. No statistical difference was found in the occurrence of hypertension or tachycardia, despite the addition of adrenaline to the LIA mixture. No difference in mortality was found between the two groups (P=0.11). These results show safe use of high volume ropivacaine with adrenaline as local infiltration analgesia during total knee replacement surgery. Copyright © 2016 Elsevier B.V. All rights reserved.
Konopka, Joseph F.; Gomoll, Andreas H.; Thornhill, Thomas S.; Katz, Jeffrey N.; Losina, Elena
2015-01-01
Background: Surgical options for the management of medial compartment osteoarthritis of the varus knee include high tibial osteotomy, unicompartmental knee arthroplasty, and total knee arthroplasty. We sought to determine the cost-effectiveness of high tibial osteotomy and unicompartmental knee arthroplasty as alternatives to total knee arthroplasty for patients fifty to sixty years of age. Methods: We built a probabilistic state-transition computer model with health states defined by pain, postoperative complications, and subsequent surgical procedures. We estimated transition probabilities from published literature. Costs were determined from Medicare reimbursement schedules. Health outcomes were measured in quality-adjusted life-years (QALYs). We conducted analyses over patients’ lifetimes from the societal perspective, with health and cost outcomes discounted by 3% annually. We used probabilistic sensitivity analyses to account for uncertainty in data inputs. Results: The estimated discounted QALYs were 14.62, 14.63, and 14.64 for high tibial osteotomy, unicompartmental knee arthroplasty, and total knee arthroplasty, respectively. Discounted total direct medical costs were $20,436 for high tibial osteotomy, $24,637 for unicompartmental knee arthroplasty, and $24,761 for total knee arthroplasty (in 2012 U.S. dollars). The incremental cost-effectiveness ratio (ICER) was $231,900 per QALY for total knee arthroplasty and $420,100 per QALY for unicompartmental knee arthroplasty. Probabilistic sensitivity analyses showed that, at a willingness-to-pay (WTP) threshold of $50,000 per QALY, high tibial osteotomy was cost-effective 57% of the time; total knee arthroplasty, 24%; and unicompartmental knee arthroplasty, 19%. At a WTP threshold of $100,000 per QALY, high tibial osteotomy was cost-effective 43% of time; total knee arthroplasty, 31%; and unicompartmental knee arthroplasty, 26%. Conclusions: In fifty to sixty-year-old patients with medial unicompartmental knee osteoarthritis, high tibial osteotomy is an attractive option compared with unicompartmental knee arthroplasty and total knee arthroplasty. This finding supports greater utilization of high tibial osteotomy for these patients. The cost-effectiveness of high tibial osteotomy and of unicompartmental knee arthroplasty depend on rates of conversion to total knee arthroplasty and the clinical outcomes of the conversions. Level of Evidence: Economic Level II. See Instructions for Authors for a complete description of levels of evidence. PMID:25995491
Bitar, Alexandre Carneiro; D'Elia, Caio Oliveira; Demange, Marco Kawamura; Viegas, Alexandre Christo; Camanho, Gilberto Luis
2011-01-01
The aim of this study was to compare the surgical results from reconstruction of the medial patellofemoral ligament (MPFL) with non-operative treatment of primary patellar dislocation. Thirty-nine patients (41 knees) with patellar dislocation were randomized into two groups. One group was treated conservatively (immobilization and physiotherapy) and other was treated surgically with reconstruction of the MPFL, and the results were evaluated with a minimum follow-up of two years. The Kujala questionnaire was applied to assess pain and quality of life, and recurrences were evaluated. Pearson's chi-square test and Fisher's exact test were used in the statistical evaluation. The statistical analysis showed that the mean Kujala score was significantly lower in the conservative group (70.8), compared with the mean value in the surgical group (88.9), with p = 0.001. The surgical group presented a higher percentage of "good/excellent" Kujala score results (71.43%) than in the conservative group (25.0%), with p = 0.003. The conservative group presented a greater number of recurrences (35% of the cases), while in the surgical group there were no reports of recurrences and/or subluxation. Treatment with reconstruction of the medial patellofemoral ligament using the patellar tendon produced better results, based on the analysis of post-treatment recurrences and the better final results from the Kujala questionnaire after a minimum follow-up period of two years.
The Impact of Lumbar Spine Disease and Deformity on Total Hip Arthroplasty Outcomes.
Blizzard, Daniel J; Sheets, Charles Z; Seyler, Thorsten M; Penrose, Colin T; Klement, Mitchell R; Gallizzi, Michael A; Brown, Christopher R
2017-05-01
Concomitant spine and hip disease in patients undergoing total hip arthroplasty (THA) presents a management challenge. Degenerative lumbar spine conditions are known to decrease lumbar lordosis and limit lumbar flexion and extension, leading to altered pelvic mechanics and increased demand for hip motion. In this study, the effect of lumbar spine disease on complications after primary THA was assessed. The Medicare database was searched from 2005 to 2012 using International Classification of Diseases, Ninth Revision, procedure codes for primary THA and diagnosis codes for preoperative diagnoses of lumbosacral spondylosis, lumbar disk herniation, acquired spondylolisthesis, and degenerative disk disease. The control group consisted of all patients without a lumbar spine diagnosis who underwent THA. The risk ratios for prosthetic hip dislocation, revision THA, periprosthetic fracture, and infection were significantly higher for all 4 lumbar diseases at all time points relative to controls. The average complication risk ratios at 90 days were 1.59 for lumbosacral spondylosis, 1.62 for disk herniation, 1.65 for spondylolisthesis, and 1.53 for degenerative disk disease. The average complication risk ratios at 2 years were 1.66 for lumbosacral spondylosis, 1.73 for disk herniation, 1.65 for spondylolisthesis, and 1.59 for degenerative disk disease. Prosthetic hip dislocation was the most common complication at 2 years in all 4 spinal disease cohorts, with risk ratios ranging from 1.76 to 2.00. This study shows a significant increase in the risk of complications following THA in patients with lumbar spine disease. [Orthopedics. 2017; 40(3):e520-e525.]. Copyright 2017, SLACK Incorporated.
Knee arthrodesis with the Vari-Wall nail for treatment of infected total knee arthroplasty.
Garcia-Lopez, Ignacio; Aguayo, Miguel Anguel; Cuevas, Antonio; Navarro, Pablo; Prieto, Cristobal; Carpintero, Pedro
2008-12-01
We reviewed 20 patients who had undergone one-stage (7 cases) or two-stage (13 cases) knee arthrodesis using the Vari-Wall intramedullary nail, as a salvage operation following infection of a total knee arthroplasty. The procedure was followed by systemic antibiotic administration and early rehabilitation. Intraoperative microbiological cultures were taken. The average period of follow-up was 20 months. Solid union was achieved in 80%; mean time to fusion was 9 months. There was no recurrence of infection. The average limb length discrepancy was 2.45 cm. A walking aid was needed by 95% of the patients. The complication rate was 30% including 4 pseudarthroses, one intraoperative fracture and one peroneal nerve palsy. The Vari-Wall intramedullary nail is a good option when an arthrodesis is indicated for salvage of an infected total knee arthroplasty. It can be performed in one or two stages depending on several factors such as microbiologic culture results. It achieved good pain relief and acceptable functional results in this study.
[Injuries to permanent teeth. Part 2: Therapy of avulsion].
von Arx, Thomas; Chappuis, Vivianne; Hänni, Stefan
2005-01-01
The present paper describes the current treatment philosophy of dislocated or avulsed permanent teeth at our school. Splinting and medication (root canal treatment, systemic antibiotics, etc.) are targeted to minimize the initial inflammatory reaction and to reduce post-traumatic complications such as pulp necrosis and/ or external root resorption.
Slipped Distal Femoral Epiphysis in Congenital Insensitivity to Pain.
Shaikh, M Javed; Rex, C; Vignesh, R; Chavan, Madhav
2016-01-01
Congenital insensitivity to pain (CIP) is a rare disorder, and often presents to an orthopaedic surgeon as recurrent fractures, dislocations, pseudoarthrosis, osteomyelitis etc. Here, we report a case of congenital insensitivity to pain presenting with distal femoral physeal separation in a child. A 12-year-old girl child came with complaints of limp while walking and swelling in the left knee for past 5 weeks. Mother gave a history that the girl is a known case of congenital insensitivity to pain with clear history of no pain on intramuscular injection since birth. She was born of consanguineous marriage and had no significant trauma, fever, other joint involvement or any features of rheumatism. On local examination, she had no bony tenderness, mild warmth, and moderate knee effusion with restricted range of movement. Plain radiograph showed epiphysiolysis of distal femur with widening of physis. Examination under anaesthesia demonstrated gross movement indicating lower femoral physeal separation. This unstable distal femoral epiphysis was treated under general anaesthesia with closed reduction, percutaneous cross pinning and above knee plaster cast. Congenital insensitivity to pain (CIP) is a rare disorder to diagnose. Emphasis is given on early diagnosis of orthopaedic problems and prompt treatment, educating parents and prevention of accidents. Physeal separation without significant trauma must prompt an orthopaedic surgeon to think about congenital insensitivity to pain as a differential diagnosis.
Changes of rabbit meniscus influenced by hyaline cartilage injury of osteoarthritis.
Zhao, Jiajun; Huang, Suizhu; Zheng, Jia; Zhong, Chunan; Tang, Chao; Zheng, Lei; Zhang, Zhen; Xu, Jianzhong
2014-01-01
Osteoarthritis (OA) is a common disease in the elderly population. Most of the previous OA-related researches focused on articular cartilage degeneration, osteophyte formation and synovitis etc. However, the role of the meniscus in these pathological changes has not been given enough attention. The goal of our study was to find the pathological changes of the meniscus in OA knee and determine their relationship. 20 months old female Chinese rabbits received either knee damaging operations with articular cartilage scratch method or sham operation randomly on one of their knees. They were sacrificed after 1-6 weeks post-operation. Medial Displacement Index (MDI) for meniscus dislocation, hematoxylin and eosin (HE) for routine histological evaluation, Toluidine blue (TB) stains for evaluating proteoglycans were carried out. Immunohistochemical (IHC) staining was performed with a two-step detection kit. Histological analysis showed chondrocyte clusters around cartilage lesions and moderate loss of proteoglycans in the operation model, as well as MDI increase and all characteristics of OA. High expression of MMP-3 and TIMP-1 also were found in both hyaline cartilage and meniscus. Biomechanical and biochemistry environment around the meniscus is altered when OA occur. If meniscus showed degeneration, subluxation and dysfunction, OA would be more severe. Prompt repair or reconstruction of hyaline cartilage in weight bearing area when it injured could prevent meniscus degeneration and subluxation, then prevent the development of OA.
Ren Shiyou; Sun, Limang; Chen, Guofei; Jiang, Changqing; Zhang, Xintao; Zhang Wentao
2015-01-01
To investigate the reliability of the "ripple sign" on the upper surface of the medial femoral condyle in the diagnosis of medial longitudinal meniscal tears under arthroscope. Between June 2013 and June 2014, 56 patients with knee injuries were included. There were 35 males and 21 females with an average age of 22.2 years (range, 12-38 years). The causes of injury were sports in 40 cases, falling in 10 cases, and traffic accident in 6 cases. The injury was located at the left knee in 22 cases and at the right knee in 34 cases. The disease duration was 10-40 days (mean, 20.2 days). Of 56 patients, 15 cases had simple medial meniscal injury; 41 cases had combined injuries, including anterior cruciate ligament injury in 38 cases, posterior cruciate ligament injury in 2 cases, and patellar dislocation in 1 case. The "ripple sign" was observed under arthroscope before operation. Repair of medial meniscal injury and reconstruction of cruciate ligament were performed. The positive "ripple sign" was seen under arthroscope in all patients, who were diagnosed to have longitudinal meniscal tears, including 23 cases of mild "ripple sign" , 28 cases of moderate "ripple sign", and 5 cases of severe "ripple sign". The "ripple sign" on the upper surface of the medial femoral condyle is a reliable diagnostic evidence of medial longitudinal meniscal tears.
Reznik, J E; Biros, E; Sacher, Y; Kibrik, O; Milanese, S; Gordon, S; Galea, M P
2017-01-01
Neurogenic heterotopic ossification (NHO) occurs as a complication of traumatic brain injury (TBI). Management of clinically significant NHO remains variable. Complications of mature NHO include limitation of mobility. The effect of the extracorporeal shock wave therapy (ESWT) on range of motion at hip and knee, and function in patients with TBI with chronic NHO was investigated. A series of single-case studies applying ESWT to chronic NHO at the hip or knee of 11 patients with TBI were undertaken at a rehabilitation hospital. Participants received four applications of high-energy EWST delivered to the affected hip or knee over a period of 8 weeks. Two-weekly follow- up assessments were carried out; final assessments were made 3 and 6 months post-intervention. Range of motion (ROM) and Functional Reach (FR) or Modified Functional Reach (MFR) were measured. Application of high-energy ESWT was associated with significant improvement in ROM (flexion) of the NHO-affected knee (Tau = 0.833, 95% CI 0.391-1.276, p = 0.002) and significant improvement of FR (Overall Tau 0.486, 95% CI 0.141-0.832, p = 0.006); no significant improvement in hip ROM or MFR. ESWT may improve mobility and balance of patients with TBI who have chronic NHO.
Suture anchor repair of quadriceps tendon rupture after total knee arthroplasty.
Kim, Tae Won B; Kamath, Atul F; Israelite, Craig L
2011-08-01
Disruption of the extensor mechanism after total knee arthroplasty (TKA) is a devastating complication, usually requiring surgical repair. Although suture anchor fixation is well described for repair of the ruptured native knee quadriceps tendon, no study has discussed the use of suture anchors in quadriceps repair after TKA. We present an illustrative case of successful suture anchor fixation of the quadriceps mechanism after TKA. The procedure has been performed in a total of 3 patients. A surgical technique and brief review of the literature follows. Suture anchor fixation of the quadriceps tendon is a viable option in the setting of rupture after TKA. Copyright © 2011 Elsevier Inc. All rights reserved.
Lyme Disease Presenting as a Spontaneous Knee Effusion.
Matzkin, Elizabeth; Suslavich, Kaytelin; Curry, Emily J
2015-11-01
Musculoskeletal complaints, which are frequently associated with Lyme disease, often prompt patients to see a physician. In particular, transient episodes of spontaneous knee effusion are common early in the progression of Lyme disease, and, if left untreated, 60% of patients diagnosed with the disease develop Lyme arthritis. This disease is easily treated with antibiotics; therefore, inclusion of Lyme disease in the differential diagnosis as a potential cause of a spontaneous knee effusion can prevent the development of more severe symptoms associated with the disease. However, the time required to receive test results and the inconsistencies between serum and synovial tests can complicate diagnosis of the disease. Copyright 2015 by the American Academy of Orthopaedic Surgeons.
Ali, Mujtaba M; Loretz, Lorraine; Shea, Art; Poorvu, Eli; Robinson, William P; Schanzer, Andres; Messina, Louis M; Baril, Donald T
2013-11-01
Despite advances in the treatment of peripheral arterial disease, a significant number of patients ultimately require major amputations. Traditionally, postoperative management of a below-knee amputation involves soft compressive dressings to allow for complete stump healing before initial prosthesis fitting. This technique is associated with a prolonged period of limited mobility, placing patients at risk for deconditioning or fall with a risk of injury to the stump. In contrast, immediate postoperative prosthesis (IPOP) placement allows patients to begin ambulation and rehabilitation on postoperative day 1, which may be of significant physiologic and psychological benefit. The purpose of this study is to compare the outcomes of patients undergoing IPOP placement to those of a historical control group managed with traditional soft compressive dressing placement. Medical records of all consecutive below-knee amputation patients who underwent IPOP (IPOP group; 37 patients, 2007-2010) and all patients who underwent traditional soft compressive dressing placement and were IPOP candidates (non-IPOP group; 35 patients, 2006-2007) were retrospectively reviewed. Patient comorbidities and preoperative ambulation status were compared between the IPOP and the non-IPOP groups. Primary outcomes evaluated included perioperative systemic complications, wound complications, need for surgical revision, and the time until placement of a definitive prosthesis. Data were analyzed using the chi-squared and Student's t-test. Preoperative comorbidities and patient characteristics of the 2 groups were similar, although the IPOP group was younger (61.5 vs. 69.0 years; P=0.01). Immediate perioperative systemic complication rates were not significantly different between the 2 groups (IPOP 29.7% vs. non-IPOP 31.4%; P=0.876). Postoperative wound complication rates were as follows: wound infection (IPOP 18.9% vs. non-IPOP 25.0%; P=0.555), wound dehiscence (IPOP 29.7% vs. non-IPOP 25.0%; P=0.673), and skin breakdown separate from the incision (IPOP 18.9% vs. non-IPOP 3.6%; P=0.062). Patients in the IPOP group trended towards fewer postoperative falls (IPOP 10.8% vs. non-IPOP 21.4%; P=0.240). The need for revision was significantly greater in the non-IPOP group (IPOP 5.4% vs. non-IPOP 27.6%; P=0.013). The time from surgery to placement of the preparatory prosthesis was 51 days in the IPOP group. Patients undergoing IPOP have similar perioperative systemic and wound complication rates compared to those patients undergoing conventional below-knee amputation, but are less likely to require surgical revision. The use of IPOP allows for early ambulation and rehabilitation, which may be of psychological benefit and may decrease the sequelae of prolonged immobilization. IPOP application should be considered for all appropriate candidates requiring below-knee amputation. Copyright © 2013 Elsevier Inc. All rights reserved.
... Wrist Elbow Armpit Penis Nipple Waist Buttocks Shoulder blades The head, face, neck, palms, and soles often ... knee, and on the penis, breast, or shoulder blades. Possible Complications The intense itching of scabies leads ...
Li, Guoliang; Han, Guangpu; Zhang, Jinxiu; Ma, Shiqiang; Guo, Donghui; Yuan, Fulu; Qi, Bingbing; Shen, Runbin
2013-07-01
To explore the application value of self-made tibial mechanical axis locator in tibial extra-articular deformity in total knee arthroplasty (TKA) for improving the lower extremity force line. Between January and August 2012, 13 cases (21 knees) of osteoarthritis with tibial extra-articular deformity were treated, including 5 males (8 knees) and 8 females (13 knees) with an average age of 66.5 years (range, 58-78 years). The disease duration was 2-5 years (mean, 3.5 years). The knee society score (KSS) was 45.5 +/- 15.5. Extra-articular deformities included 1 case of knee valgus (2 knees) and 12 cases of knee varus (19 knees). Preoperative full-length X-ray films of lower extremities showed 10-21 degrees valgus or varus deformity of tibial extra joint. Self-made tibial mechanical axis locator was used to determine and mark coronal tibial mechanical axis under X-ray before TKA, and then osteotomy was performed with extramedullary positioning device according to the mechanical axis marker.' All incisions healed by first intention, without related complications of infection and joint instability. All patients were followed up 5-12 months (mean, 8.3 months). The X-ray examination showed < 2 degrees knee deviation angle in the others except 1 case of 2.9 degrees knee deviation angle at 3 days after operation, and the accurate rate was 95.2%. No loosening or instability of prosthesis occurred during follow-up. KSS score was 85.5 +/- 15.0 at last follow-up, showing significant difference when compared with preoperative score (t=12.82, P=0.00). The seft-made tibial mechanical axis locator can improve the accurate rate of the lower extremity force line in TKA for tibia extra-articular deformity.
Zhao, Zhi-Dong; Li, Peng-Cui; Wei, Xiao-Chun
2017-11-25
Up to now, surgical treatment of recurrent lateral patellar dislocation mainly includes: medial patellofemoral ligament reconstruction, tibial tubercle osteotomy, trochleoplasty, lateral retinacular release, derotation osteotomy and so on . Clinical reports show that: the use of a single or combined with several methods have achieved ideal short to mid-term clinical outcomes. However, there is no consolidate criterion concerning the choices of different kinds of surgical ways for the treatment of individual recurrent lateral patellar dislocation. Meanwhile, with the wide use of MPFL reconstruction and other surgical options, there are more and more complications and failures that are worthy and necessary for us to pay attention to, even though its high success rate. The aim of this article is to make a systematic review of the application status of different surgical methods, collecting the positive results we have achieved, illuminating application keys of surgical techniques, guiding patient-specific therapy more precisely. Copyright© 2017 by the China Journal of Orthopaedics and Traumatology Press.
Ventham, Nicholas T; Phadnis, Joideep; Sujenthiran, Arunan; Trompeter, Alex J; Ramesh, Palanisamy
2013-01-01
Transcalcaneal talonavicular dislocation is a rare injury, with very few reported cases. Of these, most have been the result of high-energy mechanisms such as road traffic collisions or falls from a height. The management of this injury is challenging, and treatment is fraught with a high rate of disability, infection, and amputation. We describe the successful management of the first reported case of a low-energy transcalcaneal talonavicular dislocation in a 71-year-old female. Combined external and internal fixation was used to reduce and maintain the injury, with a resultant good functional and complication-free outcome at 1 year after the injury. Our experience highlights the prevalence of these devastating injuries caused by relatively benign mechanisms in an increasingly older population with osteoporotic bone. It also indicates that operative stabilization of a low-energy injury can be more successful than that with the traditional high-velocity trauma. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Lunate fractures and associated radiocarpal and midcarpal instabilities: a systematic review.
Shunmugam, Meenalochani; Phadnis, Joideep; Watts, Amy; Bain, Gregory I
2018-01-01
The aim of this study was to analyse lunate fractures and any associated osseo-ligamentous injuries. A systematic review identified 34 cases. We identified carpal instabilities at the radiocarpal and midcarpal joints in volar and dorsal directions. Radiocarpal instabilities (10/34) were usually dorsoradial (8/10), with a transverse lunate fracture, best seen on a coronal image. Midcarpal instabilities (24/34) were usually volar (14/18), with a volar lunate shear fracture, best seen on a sagittal image. Instabilities were sub-classified into non-displaced, subluxated and dislocated. Associated fractures of the scaphoid and the radial and ulnar styloid processes were common. Lunate fractures without subluxation or dislocation had good outcomes with cast immobilization or fixation of associated fractures. Lunate fracture-subluxations are unstable injuries that are best managed with fixation of the carpal fractures. Lunate fracture-dislocations are complex injuries, requiring stabilization of the lunate, associated fractures and ligament injuries; complications are common and acute or delayed salvage procedures may be required.
Clinical Evaluation and Physical Exam Findings in Patients with Anterior Shoulder Instability.
Lizzio, Vincent A; Meta, Fabien; Fidai, Mohsin; Makhni, Eric C
2017-12-01
The goal of this paper is to provide an overview in evaluating the patient with suspected or known anteroinferior glenohumeral instability. There is a high rate of recurrent subluxations or dislocations in young patients with history of anterior shoulder dislocation, and recurrent instability will increase likelihood of further damage to the glenohumeral joint. Proper identification and treatment of anterior shoulder instability can dramatically reduce the rate of recurrent dislocation and prevent subsequent complications. Overall, the anterior release or surprise test demonstrates the best sensitivity and specificity for clinically diagnosing anterior shoulder instability, although other tests also have favorable sensitivities, specificities, positive likelihood ratios, negative likelihood ratios, and inter-rater reliabilities. Anterior shoulder instability is a relatively common injury in the young and athletic population. The combination of history and performing apprehension, relocation, release or surprise, anterior load, and anterior drawer exam maneuvers will optimize sensitivity and specificity for accurately diagnosing anterior shoulder instability in clinical practice.
Gupta, Anita; Huettner, Daniel P; Dukewich, Matthew
2017-03-01
Patients suffering from osteoarthritis of the knee and patients post total knee arthroplasty often develop refractory, disabling chronic knee pain. Radiofrequency ablation, including conventional, pulsed, and cooled, has recently become more accepted as an interventional technique to manage chronic knee pain in patients who have failed conservative treatment or who are not suitable candidates for surgical treatment. This systematic review aimed to analyze published studies on radiofrequency ablation to provide an overview of the current knowledge regarding variations in procedures, nerve targets, adverse events, and temporal extent of clinical benefit. A systematic review of published studies investigating conventional, pulsed, or cooled radiofrequency ablation in the setting of chronic knee pain. Medline, Google Scholar, and the Cochrane Central Register of Controlled Trials (CENTRAL) databases were reviewed for studies on radiofrequency ablation for patients with chronic knee pain through July 29, 2016. From the studies, the procedural details, outcomes after treatment, follow-up points, and complications were compiled and analyzed in this literature review. Included studies were analyzed for clinical relevance and strength of evidence was graded using either the NHLBI Quality assessment of controlled intervention studies or the NHLBI quality assessment for before-after (pre-post) studies with no control group. Seventeen total publications were identified in the search, including articles investigating conventional, pulsed, or cooled radiofrequency ablation. These studies primarily targeted either the genicular nerves or used an intraarticular approach. Of the studies, 5 were small-sized randomized controlled trials, although one involved diathermy radiofrequency ablation. There were 8 retrospective or prospective case series and 4 case reports. Utilizing the strength of evidence grading, there is a low level of certainty to suggest a superior benefit between targeting the genicular nerve, an intraarticular approach, or targeting the larger nerves such as femoral and tibial nerves. Utilizing the strength of evidence grading, there is a low level of certainty in supporting the superiority of any specific RFA procedure modality. The majority of the studies report positive patient outcomes, but the inconsistent procedural methodology, inconsistent patient assessment measures, and small study sizes limit the applicability of any specific study to clinical practice. While the wide search strategy included a variety of articles, broad conclusions and pooled data could not be obtained based on the studies analyzed. Overall, the studies showed promising results for the treatment of severe chronic knee pain by radiofrequency ablation at up to one year with minimal complications. Numerous studies, however, yielded concerns about procedural protocols, study quality, and patient follow-up. Radiofrequency ablation can offer substantial clinical and functional benefit to patients with chronic knee pain due to osteoarthritis or post total knee arthroplasty.Key words: Radiofrequency ablation, knee osteoarthritis, knee pain, genicular nerve, total knee arthroplasty (TKA), cooled radiofrequency ablation, pulsed radiofrequency ablation.
Prevention of neurological injuries during mandibular third molar surgery: technical notes
La Monaca, Gerardo; Vozza, Iole; Giardino, Rita; Annibali, Susanna; Pranno, Nicola; Cristalli, Maria Paola
2017-01-01
Summary Surgery to the mandibular third molar is common, and injuries to the inferior alveolar nerve and the lingual nerve are well-recognized complications of this procedure. The aim of these technical notes is to describe operative measures for reducing neurological complications during mandibular third molar surgery. The following procedure should be used to prevent damage to the inferior alveolar nerve: a well-designed mucoperiosteal flap, to obtain appropriate access to the surgical area; a conservative ostectomy on the distal and distal-lingual side; tooth sectioning, to facilitate its removal by decreasing the retention zones; tooth dislocation in the path of withdrawal imposed by the curvature of the root apex; and careful socket debridement, when the roots of the extracted tooth are in intimate contact with the mandibular canal. To prevent injury to the lingual nerve, it is important (I) to assess the integrity of the mandibular inner cortex and exclude the presence of fenestration, which could cause the dislocation of the tooth or its fragment into the sublingual or submandibular space; (II) to avoid inappropriate or excessive dislocation proceedings, in order to prevent lingual cortex fracture; (III) to perform horizontal mesial-distal crown sectioning of the lingually inclined tooth; (IV) to protect the lingual flap with a retractor showing the cortical ridge; and (V) to pass the suture not too apically and from the inner side in a buccal-lingual direction in the retromolar area. PMID:29299188
Profix cemented total knee replacement: a 5-year outcome review from Lagos, Nigeria.
Ugbeye, M E; Odunubi, O O; Dim, E M; Ekundayo, O O
2012-01-01
Total knee replacement is a standard treatment for severe osteoarthritis of the knees. It is however, still a novel procedure in Nigeria. Literature on the procedure and outcome of management are sparse in Nigeria. This study aimed at describing Total Knee prosthetic Replacement as it is practiced in National Orthopaedic Hospital, Lagos. Data on patients treated with Total knee replacement between 2006 and 2010 were analyzed retrospectively. The standard anterior approach, with a medial parapatellar incision under pneumatic tourniquet was used in all cases. There were a total of 59 knees in 48 patients operated, with a female: male ratio of 5:1. Patients were in the sixth to ninth decades of life. There was a statistically significant relationship between duration of symptoms and severity of angular deformity. The average pre-operative Knee score (KS) was 27 and average function score (FS) was 43. Average duration of surgery was 126.38 minutes. Tourniquet removal after wound closure was associated with reduced intra-operative blood loss (p < 0.05). Post-operative complications included peri-prosthetic fracture (1.69%), post-operative anaemia (8.47%), superficial wound dehiscence (3.39%) and foot drop (3.39%). The mean post-operative KS and FS increased to 80 and 75 respectively. Total knee replacement, though a novel procedure in our institution is beneficial to patients with severe osteoarthritis. A long term outcome study is being planned.
Mi, Bobin; Liu, Guohui; Lv, Huijuan; Liu, Yi; Zha, Kun; Wu, Qipeng; Liu, Jing
2017-04-18
Tranexamic acid (TXA) has been proven to be effective in reducing blood loss and transfusion rate after total knee arthroplasty (TKA) without increasing the risk of deep vein thrombosis (DVT) and pulmonary embolism (PE). Recently, an increasing number of studies have been interested in applying combined intravenous (IV) with intraarticular (IA) tranexamic acid in total knee arthroplasty. The purpose of this meta-analysis was to compare the blood loss and complications of combined TXA with IV TXA or IA TXA on TKA. Systematic search of literatures were conducted to identify related articles that were published in PubMed, MEDLINE, Embase, the Cochrane Library, SpringerLink, ClinicalTrials.gov, and Ovid from their inception to September 2016. All studies that compare blood loss and complications of combined TXA and IV TXA or IA TXA on TKA were included. Main outcomes were collected and analyzed by the Review Manager 5.3. Five studies were included in the present meta-analysis. There was significant difference in total blood loss and blood volume of drainage when compared combined TXA group with IV TXA group or IA TXA group (P < 0.05). There was no difference in transfusion rate and thromboembolic complications when comparing combined TXA with IV TXA or IA TXA alone (P > 0.05). Compared with administration of IA TXA or IV TXA alone on TKA, combined use of TXA has advantages in reducing total blood loss and blood volume of drainage without increasing the incidence of thromboembolic complications. We recommend combined TXA as the preferred option for patients undergoing TKA.
Ünkar, Ethem Ayhan; Öztürkmen, Yusuf; Şükür, Erhan; Çarkçı, Engin; Mert, Murat
2017-03-01
The aim of this study was to compare the radiological and functional results of posterior cruciate ligament (PCL) - retaining and posterior-stabilized total knee arthroplasties in patients with severe varus gonarthrosis. Medical records of 112 knees of 96 patients who underwent total knee arthroplasty for severe varus (≥15°) were reviewed. PCL-retaining and PCL-stabilizing groups consisted of 58 and 54 knees, respectively. Mean follow-up time was 56.6 months (range: 24-112 months). Knee Society (KS) clinical rating system was used in clinical evaluation. Range of motion, degree of flexion contracture, postoperative alignment, and complication rates were compared between the groups. Mean preoperative mechanical tibiofemoral angle was 20.1° in varus alignment, and was restored to 4.6° in valgus postoperatively. No statistically significant differences were found between PCL-stabilizing and PCL-retaining groups when KS knee scores, function scores, and flexion arc were evaluated. Two patients in PCL-retaining group underwent revision surgery due to aseptic loosening of tibial component. One patient in PCL-stabilizing group needed arthrotomy due to patellar clunk syndrome. There were no notable differences between the 2 groups and PCL-retaining design had outcomes as good as PCL-stabilizing total knee implant in osteoarthritic knees with severe varus deformity. Level III, Therapeutic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.
Influence of body position, food and beverage consumption on BIS measurements
NASA Astrophysics Data System (ADS)
Medrano, G.; Eitner, F.; Ismail, A. H.; Pikkemaat, R.; Cordes, A.; Floege, J.; Leonhardt, S.
2010-04-01
Continuous monitoring of fluid changes using bioimpedance spectroscopy (BIS) during hemodialysis could help to predict hypotensive complications and extend the patient's life. Food and beverage consumption during the treatment may influence the measurements and the calculated fluid removal. In the present article the change observed in whole body and segmental (knee-to-knee, abdomen) BIS measurements following a sequence similar to the one of dialysis treatment (lying down, sitting and eating, lying down) on healthy subjects is presented. The measurements have been performed using a commercial bioimpedance device with a frequency range of 5 kHz to 1 MHz. Knee-to-knee measurements seem to be less sensitive to these influences, compared to the standard whole body and the alternative abdomen BIS measurements. The results indicate that the individual influence of both body posture and food and beverage consumption may be superposed when combined.
Hamilton, D F; Howie, C R; Burnett, R; Simpson, A H R W; Patton, J T
2015-06-01
Worldwide rates of primary and revision total knee arthroplasty (TKA) are rising due to increased longevity of the population and the burden of osteoarthritis. Revision TKA is a technically demanding procedure generating outcomes which are reported to be inferior to those of primary knee arthroplasty, and with a higher risk of complication. Overall, the rate of revision after primary arthroplasty is low, but the number of patients currently living with a TKA suggests a large potential revision healthcare burden. Many patients are now outliving their prosthesis, and consideration must be given to how we are to provide the necessary capacity to meet the rising demand for revision surgery and how to maximise patient outcomes. The purpose of this review was to examine the epidemiology of, and risk factors for, revision knee arthroplasty, and to discuss factors that may enhance patient outcomes. ©2015 The British Editorial Society of Bone & Joint Surgery.
[Research progress of larger flexion gap than extension gap in total knee arthroplasty].
Zhang, Weisong; Hao, Dingjun
2017-05-01
To summarize the progress of larger flexion gap than extension gap in total knee arthro-plasty (TKA). The domestic and foreign related literature about larger flexion gap than extension gap in TKA, and its impact factors, biomechanical and kinematic features, and clinical results were summarized. During TKA, to adjust the relations of flexion gap and extension gap is one of the key factors of successful operation. The biomechanical, kinematic, and clinical researches show that properly larger flexion gap than extension gap can improve both the postoperative knee range of motion and the satisfaction of patients, but does not affect the stability of the knee joint. However, there are also contrary findings. So adjustment of flexion gap and extension gap during TKA is still in dispute. Larger flexion gap than extension gap in TKA is a new joint space theory, and long-term clinical efficacy, operation skills, and related complications still need further study.
Knee arthrodesis for limb salvage with an intramedullary coupled nail.
Senior, Colin J; da Assunção, Ruy E; Barlow, Ian W
2008-07-01
The demand for revision and salvage procedures after knee arthroplasty is increasing as the number of primary procedures increases. Surgical salvage techniques when revision arthroplasty is contra-indicated include above knee amputation and arthrodesis. The results of arthrodesis are functionally superior to those of amputation but not all techniques of arthrodesis are associated with good results. We present a single surgeon series of 14 consecutive patients who underwent arthrodesis of the knee with a customised intramedullary coupled nail (Mayday arthrodesis nail, Orthodesign Ltd, UK). All patients had a failed knee arthroplasty due to persistent sepsis. Pre-operative scaled radiographs were used to design and manufacture a custom-made implant for each patient. An identical surgical technique and post-operative rehabilitation regime were used in each case. The mean hospital stay was 12 days (range 6-24). Union was achieved in all but one patient at a mean of 4 months (range 3-10). One diabetic patient required subsequent above knee amputation for infected non-union. Two other patients had significant transient complications. We have found that the Mayday nail offers a straightforward, reproducible surgical option for difficult salvage surgery. Good results have been obtained in the majority of cases, avoiding the devastating consequences of above knee amputation.
Su, Alvin W; Chen, Wei-Ming; Chen, Cheng-Fong; Chen, Tain-Hsiung
2009-11-01
Reconstruction for osteosarcoma around the knee after wide resection faces the challenge of great bone defect and future limb length discrepancy in the skeletally immature patients. Modern prosthetic reconstruction may provide good results, but the longevity may be of concern and may not be affordable in certain communities. Allograft knee arthrodesis still has its role in light of bone stock preservation and cost-effectiveness. We developed the innovative trident fixation technique utilizing three Steinmann pins to minimize limb length inequality without jeopardizing knee fusion stability. Twelve patients were enrolled. The mean age was 11.5 (10-13) years. Two had high-grade osteosarcoma in proximal tibia and others in distal femur. Two patients died of oncological disease. The median follow-up of the disease-free 10 patients was 47 (41-60) months. All allograft-host bone junctions healed uneventfully without major complications except one allograft fracture. The average limb length discrepancy was 1.45 (1.0-2.1) cm at latest follow-up. This straightforward technique was successful in knee arthrodesis with minimized limb length inequality. Accordingly, in light of bone stock preservation and longevity for the young children, it may be a surgical alternative for malignant bone tumors around the knee.
Design, simulation and modelling of auxiliary exoskeleton to improve human gait cycle.
Ashkani, O; Maleki, A; Jamshidi, N
2017-03-01
Exoskeleton is a walking assistance device that improves human gait cycle through providing auxiliary force and transferring physical load to the stronger muscles. This device takes the natural state of organ and follows its natural movement. Exoskeleton functions as an auxiliary device to help those with disabilities in hip and knee such as devotees, elderly farmers and agricultural machinery operators who suffer from knee complications. In this research, an exoskeleton designed with two screw jacks at knee and hip joints. To simulate extension and flexion movements of the leg joints, bearings were used at the end of hip and knee joints. The generated torque and motion angles of these joints obtained as well as the displacement curves of screw jacks in the gait cycle. Then, the human gait cycle was simulated in stance and swing phases and the obtained torque curves were compared. The results indicated that they followed the natural circle of the generated torque in joints with a little difference from each other. The maximum displacement obtained 4 and 6 cm in hip and knee joints jack respectively. The maximum torques in hip and knee joints were generated in foot contact phase. Also the minimum torques in hip and knee joints were generated in toe off and heel off phases respectively.
The sural artery and vein as recipient vessels in free flap reconstruction about the knee.
Johnson, P E; Harris, G D; Nagle, D J; Lewis, V L
1987-04-01
The sural artery and vein were used successfully as recipient vessels in nine patients who required free flap reconstruction about the knee. The anatomy of the sural vessels and the potential advantages of their use as free flap recipients are reviewed and discussed. Indications include popliteal vessels that are absent or severely damaged, as determined by preoperative angiography. No anastomotic complications were encountered in this series, indicating that the sural artery and vein can be used successfully as recipient vessels.
Zhu, Yi-Yong; Cui, Heng-Yan; Jiang, Pan-Qiang; Wang, Jian-Liang
2013-11-01
To investigate the causes and prevention of the complications about treatment of acromioclavicular joint dislocation (Tossy III) and unstable distal clavicular fracture (Neer II) with clavicular hook plate. From January 2001 to December 2011, 246 patients with acromioclavicular joint dislocation (Tossy III) and 222 patients with unstable distal clavicular fracture (Neer II) were treated with acromioclvicular hook plate fixation,including 348 males and 120 females with an average age of 45.4 years old ranging from 21 to 80 years old. The mean time from injury to operation was 30.8 hours (ranged from 1 h to 15 d). All patients had normal shoulder function before injury. According to Karlsson evaluation standard, the cases with excellent and good function of the shoulder joint were regarded as the normal group, and the cases with poor function of shoulder joint as the abnormal group. The comparison of the range of forward flexion,backward stretch, adduction, abduction and elevation of shoulder joints between two groups was performed. The data of impingement, subacromial osteolysis, acromioclavicular arthritis, clavicular stress fracture, downward acromioclavicular joint subluxation, hook cut-out and hook break were summarized. All patients were followed up from 8 to 48 months with an average of 12.5 months. The results were excellent in 308 cases,good in 76,and poor in 84 according to Karlsson evaluation. The excellent and good rate was 82.1%. The difference of the range of forward flexion, backward stretch, adduction, abduction and elevation of shoulder joints between two groups had a statistically significant difference (P < 0.01). Among 84 poor cases, there were 41 (8.76%) in acromial impingement or inadequate place of plate hook, 12 (2.56%) with subacromial osteolysis or/and bursitis, 10 (2.14%) with acromioclavicular arthritis or painful shoulder caused by delayed dirigation,7 (1.50%) with clavicular stress fracture or interal plate upward, 6 (1.28%) with downward acromioclavicular joint subluxation, 5 (1.07%) with hook cut -out and 3 (0.64%) in hook break. The clavicular hook plate is useful for the treatment of acromioclavicular joint dislocation (Tossy III) and unstable distal clavicular fracture (Neer II). The correct place and suitable preflex of plate hook,the restoration of fiber structure around the acromioclavicular joint and the advisable dirigation contribute to the modified rate of complications.
Xu, Jian; Liu, Haifeng; Lu, Wei; Li, Dingfu; Zhu, Weimin; Ouyang, Kan; Wu, Bing; Peng, Liangquan; Wang, Daping
2018-05-24
Rockwood type IV acromioclavicular joint (ACJ) dislocation is a trauma usually needs surgical treatment. Paired EndoButton technique (PET) is used in treating such condition. However, the effect of using different types of PET (single versus double PET) for fixation remains controversial. This study aims to evaluate and compare the efficacy of single and double PET and to provide a suitable option for the surgeons. We retrospectively reviewed the charts of patients with acute Rockwood type IV ACJ dislocation who had undergone arthroscopic fixation using single or double PET fixation between March 2009 and March 2015. Seventy-eight consecutive patients identified from chart review were picked and were divided into the single and double PET group with 39 cases in each group. The indexes of visual analog scale score (VAS) for pain, the radiographs of the affected shoulder at different time points of the follow-up, the time of return to activities and sports, the constant functional score, and the Karlsson acromioclavicular joint (ACJ) score, were assessed in a minimum of 2 years postoperation. The average coracoclavicular (CC) and acromioclavicular (AC) distances of the affected joints in the double PET group were significantly smaller than those of the single PET group 2 years postoperation (P < 0.05). The average AC and CC distances in the healthy shoulder joints were significantly smaller than those of the affected joints in the single PET group (P < 0.05); however, these values were not significantly different from those of the affected joints in the double PET group (P > 0.05). The mean VAS pain score was not significantly different, while significant difference was found for the number and times of cases return to activities and sports, constant functional score, and Karlsson ACJ score (P < 0.05) between the two groups. Therefore, the double PET group has better outcome than the single PET group. Complications including redislocation, button slippage, erosion, or AC joint instability occurred in the single PET group, while the complication in the double PET group was rare. Compared with the single PET, the double PET group achieved better outcome with less complications in arthroscopically treating acute Rockwood type IV ACJ dislocation.
Aspirin or Rivaroxaban for VTE Prophylaxis after Hip or Knee Arthroplasty.
Anderson, David R; Dunbar, Michael; Murnaghan, John; Kahn, Susan R; Gross, Peter; Forsythe, Michael; Pelet, Stephane; Fisher, William; Belzile, Etienne; Dolan, Sean; Crowther, Mark; Bohm, Eric; MacDonald, Steven J; Gofton, Wade; Kim, Paul; Zukor, David; Pleasance, Susan; Andreou, Pantelis; Doucette, Steve; Theriault, Chris; Abianui, Abongnwen; Carrier, Marc; Kovacs, Michael J; Rodger, Marc A; Coyle, Doug; Wells, Philip S; Vendittoli, Pascal-Andre
2018-02-22
Clinical trials and meta-analyses have suggested that aspirin may be effective for the prevention of venous thromboembolism (proximal deep-vein thrombosis or pulmonary embolism) after total hip or total knee arthroplasty, but comparisons with direct oral anticoagulants are lacking for prophylaxis beyond hospital discharge. We performed a multicenter, double-blind, randomized, controlled trial involving patients who were undergoing total hip or knee arthroplasty. All the patients received once-daily oral rivaroxaban (10 mg) until postoperative day 5 and then were randomly assigned to continue rivaroxaban or switch to aspirin (81 mg daily) for an additional 9 days after total knee arthroplasty or for 30 days after total hip arthroplasty. Patients were followed for 90 days for symptomatic venous thromboembolism (the primary effectiveness outcome) and bleeding complications, including major or clinically relevant nonmajor bleeding (the primary safety outcome). A total of 3424 patients (1804 undergoing total hip arthroplasty and 1620 undergoing total knee arthroplasty) were enrolled in the trial. Venous thromboembolism occurred in 11 of 1707 patients (0.64%) in the aspirin group and in 12 of 1717 patients (0.70%) in the rivaroxaban group (difference, 0.06 percentage points; 95% confidence interval [CI], -0.55 to 0.66; P<0.001 for noninferiority and P=0.84 for superiority). Major bleeding complications occurred in 8 patients (0.47%) in the aspirin group and in 5 (0.29%) in the rivaroxaban group (difference, 0.18 percentage points; 95% CI, -0.65 to 0.29; P=0.42). Clinically important bleeding occurred in 22 patients (1.29%) in the aspirin group and in 17 (0.99%) in the rivaroxaban group (difference, 0.30 percentage points; 95% CI, -1.07 to 0.47; P=0.43). Among patients who received 5 days of rivaroxaban prophylaxis after total hip or total knee arthroplasty, extended prophylaxis with aspirin was not significantly different from rivaroxaban in the prevention of symptomatic venous thromboembolism. (Funded by the Canadian Institutes of Health Research; ClinicalTrials.gov number, NCT01720108 .).
Zhang, Wentao; Zhang, Xintao; Huang, Wei
2012-03-01
When knee medial collateral ligament (MCL) rupture, the upper surface of medial meniscus is exposed totally, like the gulf panoramic, which is called "panoramic views of the bay sign" or the "bay sign". To investigate the reliability and significance of the "bay sign" in diagnosis of knee MCL rupture under arthroscope. Between March 2007 and March 2011, 127 patients with knees injuries were divided into the observation group (n = 59) and control group (n = 68) based on the MRI results. In the observation group, 59 patients had MCL rupture by MRI, including 12 cases of MCL injury alone, 16 cases of MCL injury with lateral meniscus torn, 27 cases of MCL injury with anterior cruciate ligament (ACL) injury, 3 cases of MCL injury with ACL and posterior cruciate ligament (PCL) injury, and 1 case of MCL injury with patellar dislocation; there were 38 males and 21 females with an average age of 23.2 years (range, 16-39 years). In the control group, 68 patients had no MCL rupture by MRI, including 38 cases of ACL injury, 4 cases of ACL and PCL injury, and 26 cases of ACL and lateral meniscus injury; there were 45 males and 23 females with an average age of 31.8 years (range, 25-49 years). The "bay sign" was observed under arthroscope in 2 groups before and after operation. The positive "bay sign" was seen under arthroscope in the patients of the observation group before MCL repair; the "bay sign" disappeared after repair. No "bay sign" was seen in patients of the control group before and after ACL reconstruction. The "bay sign" is a reliable diagnostic evidence of MCL injury. It can be used as a basis to judge the success of MCL reconstruction during operation.
Groen, V A; van de Graaf, V A; Scholtes, V A B; Sprague, S; van Wagensveld, B A; Poolman, R W
2015-02-01
Obesity is a major risk factor for the development of knee osteoarthritis, and over the past 30 years the prevalence of obesity has more than doubled. In an advanced-stage knee osteoarthritis is treated with total knee arthroplasty, and the demand for primary total knee arthroplasties is expected to grow exponentially. However, total knee arthroplasty in obese patients is associated with more complications, longer hospital stay and higher costs. We aimed to determine the effects of bariatric surgery on knee complaints in (morbidly) obese (body mass index >30 kg m(-2) ) adult patients. The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, TRIP, BIOSIS-Previews and reference lists of retrieved publications were systematically searched from earliest available up to 20 April 2014 for any English, German, French and Dutch studies. There was no restriction on study design. We included studies on the effect of surgically induced weight reduction on knee complaints in (morbidly) obese adult patients, with a minimal follow-up of 3 months. Studies on the effects of lipectomy or liposuction and studies in which patients had already received a total knee arthroplasty were excluded. Thirteen studies were included in this systematic review with a total of 3,837 patients. Although different assessment tools were used, an overall significant improvement in knee pain was seen in 73% out of the used assessments. All studies measuring intensity of knee pain, knee physical function and knee stiffness showed a significant improvement after bariatric surgery. The quality of evidence was very low or too low for most of the included studies and moderate for one study. Bariatric surgery with subsequent marked weight loss is likely to improve knee pain, physical function and stiffness in (morbidly) obese adult patients. However, with the current available evidence, there is need for high-quality studies. © 2014 World Obesity.
Amar, Eyal; Maman, Eran; Khashan, Morsi; Kauffman, Ehud; Rath, Ehud; Chechik, Ofir
2012-11-01
The shoulder is regarded as the most commonly dislocated major joint in the human body. Most dislocations can be reduced by simple methods in the emergency department, whereas others require more complicated approaches. We compared the efficacy, safety, pain, and duration of the reduction between the Milch technique and the Stimson technique in treating dislocations. We also identified factors that affected success rate. All enrolled patients were randomized to either the Milch technique or the Stimson technique for dislocated shoulder reduction. The study cohort consisted of 60 patients (mean age, 43.9 years; age range, 18-88 years) who were randomly assigned to treatment by either the Stimson technique (n = 25) or the Milch technique (n = 35). Oral analgesics were available for both groups. The 2 groups were similar in demographics, patient characteristics, and pain levels. The first reduction attempt in the Milch and Stimson groups was successful in 82.8% and 28% of cases, respectively (P < .001), and the mean reduction time was 4.68 and 8.84 minutes, respectively (P = .007). The success rate was found to be affected by the reduction technique, the interval between dislocation occurrence and first reduction attempt, and the pain level on admittance. The success rate and time to achieve reduction without sedation were superior for the Milch technique compared with the Stimson technique. Early implementation of reduction measures and low pain levels at presentation favor successful reduction, which--in combination with oral pain medication--constitutes an acceptable and reasonable management alternative to reduction with sedation. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Gutkowska, Olga; Martynkiewicz, Jacek; Gosk, Jerzy
2017-01-01
Anterior glenohumeral dislocation affects about 2% of the general population during the lifetime. The incidence of traumatic glenohumeral dislocation ranges from 8.2 to 26.69 per 100 000 population per year. The most common complication is recurrent dislocation occurring in 17–96% of the patients. The majority of patients are treated conservatively by closed reduction and immobilization in internal rotation for 2–3 weeks. However, no clear conservative treatment protocol exists. Immobilization in external rotation can be considered an alternative. A range of external rotation braces are commercially available. The purpose of this work was to review the current literature on conservative management of glenohumeral dislocation and to compare the results of immobilization in internal and external rotation. A comprehensive literature search and review was performed using the keywords “glenohumeral dislocation”, “shoulder dislocation”, “immobilization”, “external rotation”, and “recurrent dislocation” in PubMed, MEDLINE, Cochrane Library, Scopus, and Google Scholar databases from their inceptions to May 2016. Three cadaveric studies, 6 imaging studies, 10 clinical studies, and 4 meta-analyses were identified. The total number of 734 patients were included in the clinical studies. Literature analysis revealed better coaptation of the labrum on the glenoid rim in external rotation in cadaveric and imaging studies. However, this tendency was not confirmed by lower redislocation rates or better quality of life in clinical studies. On the basis of the available literature, we cannot confirm the superiority of immobilization in external rotation after glenohumeral dislocation when compared to internal rotation. A yet-to-be-determined group of patients with specific labroligamentous injury pattern may benefit from immobilization in external rotation. Further studies are needed to identify these patients. PMID:28710344
[Indications for arthrodesis of the knee joint in modern orthopedics].
Hart, R; Janecek, M; Bucek, P; Procházka, V; Visna, P
2003-04-01
Indication for arthrodesis of the knee joint is nowadays most frequently failure of a total endoprosthesis, usually septic. A less frequent indication is purulent gonitis, frequently after corticoid administration, the condition after a complicated intraarticular fracture with subsequent arthritis or oncological disease of the bones in the area of the knee joint. In the course of 2000 to 2002 at the authors' department 15 arthrodeses were implanted. In three cases the indication for arthrodesis was purulent gonitis, in three cases the condition after an open articular injury associated with infectious complications and in the remaining nine cases failure of an endoprosthesis of the knee, incl. seven caused by infection. The patients were three men and 12 women, mean age 64 years (30-75 years). For stabilization of the arthrodesis 9x external fixation was used, 5x plates and 1x intramedullary osteosynthesis. In all cases consolidation of the arthrodesis was achieved. In one case the external fixation had to be replaced by a system of two fixation devices and in one case correction of the axial position of the extremity was made. The presence of external fixation was perceived negatively in particular by female patients. Plate osteosynthesis and the use of external fixation devices are relatively quick, cheap and considerate methods of arthrodesis. External fixation must be used in acute virulent infections while plate osteosynthesis can be indicated in its absence. The characteristic of intramedullary fixation is similar, however special nails used for arthrodesis of the knee are several times more expensive than the previous types of stabilization. The advantage is the possibility to use a massive bone graft to fill the defect.
Ha, Chul-Won; Park, Yong-Beom; Lee, Choong-Hee; Awe, Soo-Ik; Park, Yong-Geun
2016-05-01
The pie-crusting method is popular in releasing lateral tightness during primary total knee arthroplasty (TKA) but is not well described for medial release. We established a selective medial release technique using the pie-crusting technique and investigated the effectiveness and safety of the technique during primary TKA. We retrospectively reviewed 729 primary TKAs with varus deformity between October 2009 and June 2012. Medial tightness in flexion was released by traditional subperiosteal stripping for the anterior portion of the medial collateral ligament (aMCL). Medial tightness in extension was released by the pie crusting for the tight fibers in the posterior portion of the MCL and/or posteromedial corner structures (pMCL/PMCS). Clinical outcomes were evaluated by Knee Society (KS) scores and the Western Ontario and McMaster Universities Osteoarthritis Index. Any complications, including late medial instability that may be related to our surgical technique, were carefully inspected. Among the 729 knees, 170 (23.3%) required subperiosteal stripping for balancing in flexion only, 186 (25.5%) required the pie-crusting for balancing in extension only and 142 (19.5%) required subperiosteal stripping and the pie-crusting for balancing in flexion and extension. The KS knee score was improved from 52.5 to 83.4, KS function score from 58.2 to 91.9, and Western Ontario and McMaster Universities Osteoarthritis Index from 42.7 to 21.8 (P < .001, all). No specific complications related to our technique were identified. The selective medial release technique appears to be an effective and safe method to obtain a balanced mediolateral gap in primary TKA. Copyright © 2016 Elsevier Inc. All rights reserved.
Cip, Johannes; Erb-Linzmeier, Hedwig; Stadlbauer, Peter; Bach, Christian; Martin, Arno; Germann, Reinhard
2016-12-01
Sciatic nerve block (SNB) is commonly used as adjunct to femoralis nerve block (FNB) to achieve high-quality pain relief after total knee arthroplasty (TKA). However, this combination is associated with considerable muscle weakness, foot drop and surgically related nerve injuries may be masked. The purpose of this study was to assess whether low risk continuous intra-articular anesthetic drug instillation is an adequate alternative to SNB when adding to FNB after TKA. Retrospective investigational follow-up study. University teaching hospital. Interdisciplinary postoperative anesthetic and orthopedic survey. For this investigational analysis, 34 of 50 consecutive patients were available. All patients underwent primary unilateral TKA. Group A (18 patients) received a continuous intra-articular 0.33% ropivacaine (5 mL/h) instillation for the first 48 h postoperatively. In Group B (16 patients) a discontinuous SNB was used. Both groups were treated with a continuous FNB. Main endpoints were mean and maximum postoperative pain intensity levels for both anterior and posterior knee side, amount of postoperative administered opioid drugs, differences in functional outcome or hospital stay and rate of postoperative complications. Group A showed higher pain intensity levels for the posterior knee side (P≤.042). Merely on the second postoperative day there were no differences within either study group. No differences were found regarding anterior knee pain. Group A showed a significant higher postoperative piritramid consumption (P≤.007). Length of hospital stay or postoperative functional outcome was not significant different. Postoperative complications were not related to anesthesia techniques. SNB technique resulted in superior pain relief in comparison to continuous intra-articular local anesthetic drug instillation as adjunct to continuous FNB after TKA. Copyright © 2016 Elsevier Inc. All rights reserved.
Compartment syndrome after total knee arthroplasty: regarding a clinical case☆
Pinheiro, Ana Alexandra da Costa; Marques, Pedro Miguel Dantas Costa; Sá, Pedro Miguel Gomes; Oliveira, Carolina Fernandes; da Silva, Bruno Pombo Ferreira; de Sousa, Cristina Maria Varino
2015-01-01
Although compartment syndrome is a rare complication of total knee arthroplasty, it is one of the most devastating complications. It is defined as a situation of increased pressure within a closed osteofascial space that impairs the circulation and the functioning of the tissues inside this space, thereby leading to ischemia and tissue dysfunction. Here, a clinical case of a patient who was followed up in orthopedic outpatient consultations due to right gonarthrosis is presented. The patient had a history of arthroscopic meniscectomy and presented knee flexion of 10° before the operation, which consisted of total arthroplasty of the right knee. The operation seemed to be free from intercurrences, but the patient evolved with compartment syndrome of the ipsilateral leg after the operation. Since compartment syndrome is a true surgical emergency, early recognition and treatment of this condition through fasciotomy is crucial in order to avoid amputation, limb dysfunction, kidney failure and death. However, it may be difficult to make the diagnosis and cases may not be recognized if the cause of compartment syndrome is unusual or if the patient is under epidural analgesia and/or peripheral nerve block, which thus camouflages the main warning sign, i.e. disproportional pain. In addition, edema of the limb that underwent the intervention is common after total knee arthroplasty operations. This study presents a review of the literature and signals that the possible rarity of cases is probably due to failure to recognize this condition in a timely manner and to placing these patients in other diagnostic groups that are less likely, such as neuropraxia caused by using a tourniquet or peripheral nerve injury. PMID:26401507
Manoharan, Varaguna; Grant, Andrea L; Harris, Alicia C; Hazratwala, Kaushik; Wilkinson, Matthew P R; McEwen, Peter J C
2016-11-01
The purpose of this study was to assess the effect of negative pressure wound therapy (NPWT) on quality of life (QoL), wound complications, and cost after primary knee arthroplasty. A prospective analysis of 33 patients undergoing primary knee arthroplasty performed by 3 surgeons in one institution. The first 12 patients (3 bilateral and 9 unilateral) had conventional dry dressings (CDD) applied and cost of dressings was assessed. The other 21 patients all underwent bilateral knee arthroplasty and had either side randomized to receiving NPWT or CDD. Cost of dressings, wound complications, and QoL were compared. One patient had a reaction to the NPWT requiring readmission. Another had persistent wound drainage that required NPWT application. There were no wound issues in the remaining 31 patients. The average cost in the first 12 patients was Australian dollar $48.70 with an average of 1.5 changes on ward. In the 21 patients receiving both dressings, the average cost for CDD was less (Australian dollar $43.51 vs $396.02, P ≤ .011, effect size [ES] = 1.06). When comparing QoL factors, wound leakage (0.14 vs 0.39 P = .019, ES = 1.02), and wound protection (0.16 vs 0.33, P = .001, ES = 0.021) were better in the NPWT group. There was no other significant difference in QoL factors. The average number of changes on the ward was less for the NPWT group (1.19 vs 1.38, P = .317, ES = 1.02). We found no benefit in wound healing or cost with NPWT post knee arthroplasty. There was some benefit in NPWT QoL factors less wound leakage and better protection. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
[New classification of Crowe type IV developmental dysplasia of the hip].
Ma, Hai-yang; Zhou, Yong-gang; Zheng, Chong; Cao, Wen-zhe; Wang Sen; Wu, Wen-ming; Piao, Shang; Du, Yin-qiao
2016-02-01
To compare differences between Crowe IV developmental dysplasia of the hip (DDH) with secondary acetabulum and Crowe IV DDH without secondary acetabulum,and determine whether it is necessary to divide Crowe IV DDH into two subtypes. From June 2007 to May 2015,145 hips of 112 Crowe N patients who underwent total hip arthroplasty (THA) using S-ROM stem were divided into two groups: secondary acetabulum formaton group (group A) and no secondary acetabulum formaton group (group B). In group A,there were 12 females, 96 males,with an average age of (39.38 ± 11.19) years old. In group B, there were 2 females, 35 males, with an average age of (38.19 ± 10.92) years old. All the patients were evaluated by using Harris Hip Score. Radiographic evaluations were made preoperatively and during follow up. The differences between two groups were compared on dislocation height, canal flare index (CFI), subtrochanteric shortening osteotomy (SSTO) usage, pre- and post-operation Harris scores, complications. The dislocation height for group A was (4.74 ± 1.57) cm, while the dislocation height for group B was (3.12 ± 1.15) cm. Significantly difference was detected between two groups. The CFI for group A was 2.69 ± 0.68, while the CFI for group B was 3.42 ± 0.79, and the significantly difference was detected between two groups. Harris scores were totally improved from 58.18 ± 15.67 preoperatively to 91.20 ± 3.79 post-operatively and the difference was significant. Pre-operative Harris scores was 58.1 ± 15.3 in group A, 58.3 ± 16.9 in group B. Post-operative Harris scores was 91.0 ± 4.1 in group A, 91.0 ± 5.1 in group B. No significant difference was found on Harris scores between A and B preoperatively and post-operatively. Complications of 4 cases peri-prosthesis fracture, 4 cases dislocation and 4 cases nerve injury occur in group A; While only one case dislocation and one case nerve injury occur in group B. No statistical significance was detected. Crowe IV DDH with secondary acetabulum is significantly different from Crowe IV DDH without secondary acetabulum on dislocation height and femoral morphology, which causes the different selections of surgical techniques (SSTO usage or not). These important differences in fundamental parameters indicate the necessity to further divide Crowe IV DDH into IVA and IVB two subtypes.
Kinematic alignment technique for total hip and knee arthroplasty
Rivière, Charles; Lazic, Stefan; Villet, Loïc; Wiart, Yann; Allwood, Sarah Muirhead; Cobb, Justin
2018-01-01
Conventional techniques for hip and knee arthroplasty have led to good long-term clinical outcomes, but complications remain despite better surgical precision and improvements in implant design and quality. Technological improvements and a better understanding of joint kinematics have facilitated the progression to ‘personalized’ implant positioning (kinematic alignment) for total hip (THA) and knee (TKA) arthroplasty, the true value of which remains to be determined. By achieving a true knee resurfacing, the kinematic alignment (KA) technique for TKA aims at aligning the components with the physiological kinematic axes of the knee and restoring the constitutional tibio-femoral joint line frontal and axial orientation and soft-tissue laxity. The KA technique for THA aims at restoring the native ‘combined femoro-acetabular anteversion’ and the hip’s centre of rotation, and occasionally adjusting the cup position and design based on the assessment of the individual spine-hip relation. The key element for optimal prosthetic joint kinematics (hip or knee) is to reproduce the femoral anatomy. The transverse acetabular ligament (TAL) is the reference landmark to adjust the cup position. Cite this article: EFORT Open Rev 2018;3:98-105. DOI: 10.1302/2058-5241.3.170022 PMID:29657851
Sahota, Shawn; Lovecchio, Francis; Harold, Ryan E; Beal, Matthew D; Manning, David W
2018-01-01
Total joint arthroplasty (TJA) is a highly successful treatment, but is burdensome to the national healthcare budget. National quality initiatives seek to reduce costly complications. Smoking's role in perioperative complication after TJA is less well known. This study aims to identify smoking's independent contribution to the risk of short-term complication after TJA. All patients undergoing primary TJA between 2011 and 2012 were selected from the American College of Surgeon's National Surgical Quality Improvement Program's database. Outcomes of interest included rates of readmission, reoperation, mortality, surgical complications, and medical complications. To eliminate confounders between smokers and nonsmokers, a propensity score was used to generate a 1:1 match between groups. A total of 1251 smokers undergoing TJA met inclusion criteria. Smokers in the combined total hip and knee arthroplasty cohort had higher 30-day readmission (4.8% vs 3.2%, P = .041), were more likely to have a surgical complication (odds ratio 1.84, 95% confidence interval 1.21-2.80), and had a higher rate of deep surgical site infection (SSI) (1.1% vs 0.2%, P = .007). Analysis of total hip arthroplasty only revealed that smokers had higher rates of deep SSI (1.3% vs 0.2%, P = .038) and higher readmission rate (4.3% vs 2.2%, P = .034). Analysis of total knee arthroplasty only revealed greater surgical complications (2.8% vs 1.2%, P = .048) and superficial SSI (1.8% vs 0.2%, P = .002) in smokers. Smoking in TJA is associated with higher rates of SSI, surgical complications, and readmission. Copyright © 2017 Elsevier Inc. All rights reserved.
Arthroscopic isolated posterior labral repair in rugby players
Badge, Ravi; Tambe, Amol; Funk, Lennard
2009-01-01
Background The shoulder is the second most frequently injured joint after the knee in rugby players and labral tears appear to be common. There is limited data available in the literature regarding the mechanisms of posterior labral injury in rugby players and the management of these injuries. Objective The aim of this study is to report the clinical presentation, arthroscopic findings, surgical technique for repair, and the functional outcome in elite English rugby players with isolated posterior labral injuries. Study Design Case series (level IV evidence) Materials and Methods Over a 5-year period we surgically treated 142 elite rugby players, of whom 11 (7.8%) had isolated posterior labral injuries. All these 11 patients had significant contact injury. Only three (24%) patients had a true posterior shoulder dislocation. Pre- and postoperative assessment included Constant score, Oxford shoulder score, and Oxford instability score. We also assessed the time taken to return to preinjury level of fitness and the complications of surgery. Results Average follow-up was for 32 months (range 17–54 months). The mean Constant score improved from 66 to 99. The Oxford score indicated improvement, decreasing from 33 to 18; similarly, the Oxford instability score also decreased from 52.2 to 12.3. Return to playing rugby at peak level was at a mean of 4.3 months after arthroscopic repair. Conclusion Successful clinical results and rapid return to play can be achieved by appropriate early arthroscopic repair and supervised accelerated rehabilitation for posterior labral tears in elite rugby players. PMID:20616949
Worni, Mathias; Pietrobon, Ricardo; Zammar, Guilherme Roberto; Shah, Jatin; Yoo, Bryan; Maldonato, Mauro; Takemoto, Steven; Vail, Thomas P
2012-01-01
The Hospital Acquired Condition Strategy (HACS) denies payment for venous thromboembolism (VTE) after total knee arthroplasty (TKA). The intention is to reduce complications and associated costs, while improving the quality of care by mandating VTE prophylaxis. We applied a system dynamics model to estimate the impact of HACS on VTE rates, and potential unintended consequences such as increased rates of bleeding and infection and decreased access for patients who might benefit from TKA. The system dynamics model uses a series of patient stocks including the number needing TKA, deemed ineligible, receiving TKA, and harmed due to surgical complication. The flow of patients between stocks is determined by a series of causal elements such as rates of exclusion, surgery and complications. The number of patients harmed due to VTE, bleeding or exclusion were modeled by year by comparing patient stocks that results in scenarios with and without HACS. The percentage of TKA patients experiencing VTE decreased approximately 3-fold with HACS. This decrease in VTE was offset by an increased rate of bleeding and infection. Moreover, results from the model suggest HACS could exclude 1.5% or half a million patients who might benefit from knee replacement through 2020. System dynamics modeling indicates HACS will have the intended consequence of reducing VTE rates. However, an unintended consequence of the policy might be increased potential harm resulting from over administration of prophylaxis, as well as exclusion of a large population of patients who might benefit from TKA.
Wiley, Marcel R; Riccio, Anthony I; Felton, Kevin; Rodgers, Jennifer A; Wimberly, Robert L; Johnston, Charles E
Quengel casting was introduced in 1922 for nonsurgical treatment of knee flexion contractures (KFC) associated with hemophilic arthropathy. It consists of an extension-desubluxation hinge fixed to a cast allowing for gradual correction of a flexion deformity while preventing posterior tibial subluxation. The purpose of this study is to report 1 center's experience with this technique for the treatment of pediatric KFC. A retrospective review was conducted over a 26-year period. All patients with KFC treated with Quengel casting were included. Demographic data, associated medical conditions, adjunctive soft tissue releases, complications, and the need for late surgical intervention were recorded. Tibiofemoral angle measurements in maximal extension were recorded at initiation and termination of casting, 1-year follow-up, and final follow-up. Success was defined as no symptomatic recurrence of KFC or need for subsequent surgery. Eighteen patients (26 knees) were treated for KFC with Quengel casting. Average age at initiation of casting was 8.1 years with average follow-up of 59.9 months. Fifteen knees (58%) underwent soft tissue releases before casting. An average of 1.5 casts per knee were applied over an average of 23.9 days. Average KFC before casting was 50.6 degrees (range, 15 to 100 degrees) which improved to 5.96 degrees (0 to 40 degrees) at cast removal (P<0.00001). Sixteen patients (22 knees) had 1-year follow-up or failed casting before 1 year. Of these, 11 knees (50%) had a successful outcome. Residual KFC of those treated successfully was 6.8 degrees (range, 0 to 30 degrees) at 1 year and 8.2 degrees (range, 0 to 30 degrees) at final follow-up, averaging 71.4 months (P=0.81). Of the 11 knees deemed failures, all had recurrence of deformity within an average of 1 year from cast removal. Surgical release before Quengel casting did not improve the chances for success (P=0.09). Quengel casting can improve pediatric KFC an average of 44.2 degrees with minimal complications. Although 50% of treated patients will demonstrate significant recurrence or need later surgery, the majority of those treated successfully have durable results at intermediate term follow-up. Level IV-therapeutic study.
Accession Medical Standards Analysis and Research Activity (AMSARA), 2015 Annual Report
2016-03-01
419 4.4 Internal derangement of knee 1,705 2.2 975 2.1 384 2.5 284 3.0 Contact dermatitis and other eczema 1,558 2.0 1048 2.2 300 2.0 238 2.5...and unspecified disorders of bone and cartilage 302 2.6 254 2.8 4 2.8 3 2.5 Contact dermatitis and other eczema 280 2.4 230 2.6 6 4.2 6 4.9... Contact dermatitis and other eczema 500 2.9 181 1.7 104 2.8 26 1.3 Hearing loss 607 3.6 94 0.9 100 2.7 6 0.3 Recurrent dislocation of joint 263
Blizzard, Daniel J; Penrose, Colin T; Sheets, Charles Z; Seyler, Thorsten M; Bolognesi, Michael P; Brown, Christopher R
2017-08-01
Ankylosing spondylitis (AS) is a chronic autoimmune spondyloarthropathy that primarily affects the axial spine and hips. Progressive disease leads to pronounced spinal kyphosis, positive sagittal balance, and altered biomechanics. The purpose of this study is to determine the complication profile of patients with AS undergoing total hip arthroplasty (THA). The Medicare sample was searched from 2005 to 2012 yielding 1006 patients with AS who subsequently underwent THA. Risk ratios (RRs) with 95% confidence intervals (CIs) were calculated for 90-day, 2-year, and the final postoperative follow-up for complications including hip dislocation, periprosthetic fracture, wound complication, revision THA, and postoperative infection. Compared to controls, AS patients had an RR of 2.50 (CI, 1.04-5.99) of THA component breakage at 90-days post-operatively and 1.99 (CI, 1.10-3.59) at 2-years. The RR of periprosthetic hip dislocation was elevated at 90 days (1.44; CI, 0.93-2.22) and significantly increased at 2-years (1.67; CI, 1.25-2.23) and overall follow-up (1.49; CI, 1.14-1.93). Similarly, the RR for THA revision was elevated at 90-days (1.46; CI, 0.97-2.18) and significantly increased at 2-years (1.69; CI, 1.33-2.14) and overall follow-up (1.51; CI, 1.23-1.85). Patients with AS are at increased risk for complications after THA. Altered biomechanics from a rigid, kyphotic spine place increased demand on the hip joints. The elevated perioperative and postoperative risks should be discussed preoperatively, and these patients may require increased preoperative medical optimization as well as possible changes in component selection and position to compensate for altered spinopelvic biomechanics. Copyright © 2017 Elsevier Inc. All rights reserved.
Terveen, Daniel C; Fram, Nicole R; Ayres, Brandon; Berdahl, John P
2016-02-01
To determine the visual outcomes and complications of a new small-incision technique for 4-point fixation of a hydrophilic acrylic posterior chamber intraocular lens (IOL) in the absence of capsule support. Three North American tertiary referral centers and a private practice. Retrospective case series. Secondary IOL placement was performed from 2011 to 2014. Indications for surgery, clinical results, and complications were analyzed. Primary outcomes included postoperative corrected distance visual acuity (CDVA) and surgical complications. Charts of 35 patients (37 eyes) were reviewed. The mean age at surgery was 56 years, and the mean follow-up was 6 months (range 3 to 24 months). Clinical indications included a dislocated IOL (30%), ocular trauma (19%), crystalline lens subluxation (19%), uveitis-glaucoma-hyphema syndrome (5%), post-complicated cataract (8%), congenital cataract (8%), and decompensated cornea (3%). The mean CDVA improved from 20/80 preoperatively to 20/40 postoperatively (P < .01). Thirty-six eyes (97%) had an improved or unchanged CDVA, and 1 eye (3%) had a reduced CDVA because of worsening glaucoma. Postoperative complications included ocular hypertension (24%), iritis (5%), wound leakage (3%), transient corneal edema (3%), glaucoma requiring a tube shunt (3%), and IOL dislocation (3%). Small-incision 4-point scleral fixation of the Akreos AO60 hydrophilic acrylic IOL in the absence of capsule support appears to be a safe and effective technique for secondary IOL placement. Drs. Berdahl and Ayres are consultants to Bausch & Lomb, Inc. Drs. Ayres and Fram have received speaker fees from Bausch & Lomb. Dr. Terveen does not have a financial or proprietary interest in any material or methods mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Park, Sang Eun; Lee, Chun Taek
2007-10-01
This study was aimed to compare robotic-assisted implantation of a total knee arthroplasty with conventional manual implantation. We controlled, randomized, and reviewed 72 patients for total knee arthroplasty assigned to undergo either conventional manual implantation (excluding navigation-assisted implantation cases) of a Zimmer LPS prosthesis (Zimmer, Warsaw, Ind) (30 patients: group 1) or robotic-assisted implantation of such a prosthesis (32 patients: group 2). The femoral flexion angle (gamma angle) and tibial angle (delta angle) in the lateral x-ray of group 1 were 4.19 +/- 3.28 degrees and 89.7 +/- 1.7 degrees, and those of group 2 were 0.17 +/- 0.65 degrees and 85.5 +/- 0.92 degrees. The major complications were from improper small skin incision during a constraint attempt of minimally invasive surgery and during bulk fixation frame pins insertion. Robotic-assisted technology had definite advantages in terms of preoperative planning, accuracy of the intraoperative procedure, and postoperative follow-up, especially in the femoral flexion angle (gamma angle) and tibial flexion angle (delta angle) in the lateral x-ray, and in the femoral flexion angle (alpha angle) in the anteroposterior x-ray. But a disadvantage was the high complication rate in early stage.
Kempthorne, Joshua T; Armour, Paul C; Rietveld, John A; Hooper, Gary J
2011-06-01
Surgical dislocation of the hip has been developed to deal with the problems causing femoroacetabular impingement (FAI). This is a relatively recent procedure that was historically reserved for larger areas specializing in hip surgery. We hypothesized that surgical dislocation can be used for symptomatic FAI in a typical Australasian tertiary orthopaedic centre with acceptable results. This prospective study reviews the results of 53 surgical dislocations in this setting, looking particularly at functional outcomes and early complications. There were significant improvements in the Western Ontario and McMaster University Osteoarthritis Index score at 1, 2, 3 and 4 years post-operatively. Western Ontario and McMaster University Osteoarthritis Index scores increased by 23, 28, 34 and 35 points, respectively (P 0.0039). There was no significant improvement in hip range of motion. There were two (4%) early failures with conversion to total hip arthroplasty, and no cases of post-operative avascular necrosis of the femoral head. We believe that as the diagnosis of FAI and conservative nonarthroplasty surgery of the hip gains wider acceptance, it will become a procedure that should be offered to all appropriate patients in an attempt to delay or limit total hip arthroplasty in this young age group.
Shih, Cheng-Min; Huang, Kui-Chou; Pan, Chien-Chou; Lee, Cheng-Hung; Su, Kuo-Chih
2015-11-01
Clavicle hook plates are frequently used in clinical orthopaedics to treat acromioclavicular joint dislocation. However, patients often exhibit acromion osteolysis and per-implant fracture after undergoing hook plate fixation. With the intent of avoiding future complications or fixation failure after clavicle hook plate fixation, we used finite element analysis (FEA) to investigate the biomechanics of clavicle hook plates of different materials and sizes when used in treating acromioclavicular joint dislocation. Using finite element analysis, this study constructed a model comprising four parts: clavicle, acromion, clavicle hook plate and screws, and used the model to simulate implanting different types of clavicle hook plates in patients with acromioclavicular joint dislocation. Then, the biomechanics of stainless steel and titanium alloy clavicle hook plates containing either six or eight screw holes were investigated. The results indicated that using a longer clavicle hook plate decreased the stress value in the clavicle, and mitigated the force that clavicle hook plates exert on the acromion. Using a clavicle hook plate material characterized by a smaller Young's modulus caused a slight increase in the stress on the clavicle. However, the external force the material imposed on the acromion was less than the force exerted on the clavicle. The findings of this study can serve as a reference to help orthopaedic surgeons select clavicle hook plates.
Laryngeal dislocation after ventral fusion of the cervical spine
Krauel, Jenny; Winkler, Dietrich; Münscher, Adrian; Tank, Sascha
2013-01-01
We report on a 70-year-old patient who underwent ventral fusion of the cervical spine (C3/4 and C4/5) for spinal canal stenosis performed by the neurosurgery department. The patient suffered an exceedingly rare complication of the surgery – laryngeal dislocation. Had the deformed laryngeal structures been overlooked and the patient extubated as usual after surgery, reintubation would have been impossible due to the associated swelling, which might have had disastrous consequences. Leftward dislocation of the larynx became apparent post-operatively, but prior to extubation. Extubation was therefore postponed and a subsequent computed tomography (CT) scan revealed entrapment of laryngeal structures within the osteosynthesis. A trial of repositioning using microlaryngoscopy performed by otolaryngology (ears, nose and throat) specialists failed, making open surgical revision necessary. At surgery, the entrapped laryngeal tissue was successfully mobilised. Laryngeal oedema developed despite prompt repositioning; thus, necessitating tracheotomy and long-term ventilation. Laryngeal dislocation may be an unusual cause of post-operative neck swelling after anterior cervical spine surgery and should be considered in the differential diagnosis if surgical site haematoma and other causes have been ruled out. Imaging studies including CT of the neck may be needed before extubation to confirm the suspicion and should be promptly obtained to facilitate specific treatment. PMID:23983289
Xia, Ming-Hua; Xie, Shui-Hua; Wu, Jun; Zhang, Wen-Qing; Chen, Wei-Dong; He, Jian-Hua; Ding, Hao; Hu, Qian-Qin; Wang, Xiao-Peng
2016-07-25
To explore the clinical effects of the triple no loop Endobutton plate combined with Orthcord line in treating acromioclavicular dislocation of Tossy type III. Between February 2011 and September 2013, 36 patients with acromioclavicular dislocation of Tossy type III were treated with triple no loop Endobutton plate and Orthcord line. There were 21 males and 15 females, aged from 9 to 48 years old with an average of (26.41±14.05) years. Couse of disease was from 2 to 7 days in the patients. The patients had the clinical manifestations such as shoulder pain, extension limited, acromioclavicular tenderness, positive organ point sign. Clinical effects were assessed by acromioclavicular scoring system. Thirty six patients were followed up from 8 to 15 months with an average of (12.2±4.3) months. All incisions got primary healing. At the final follow up, all shoulder pain vanished, acromioclavicular joints without tenderness, negative organ point sign. No redislocation and steel plate loosening were found. According to the acromioclavicular scoring system, 31 cases obtained excellent results, 5 good. The method of triple no loop Endobutton plate combined with Orthcord line for acromioclavicular dislocation of Tossy type III has advantage of less risk and complication, good functional rehabilitation and is an ideal method.
Microstructure of calcite deformed by high-pressure torsion: An X-ray line profile study
NASA Astrophysics Data System (ADS)
Schuster, Roman; Schafler, Erhard; Schell, Norbert; Kunz, Martin; Abart, Rainer
2017-11-01
Calcite aggregates were deformed to high strain using high-pressure torsion and applying confining pressures of 1-6 GPa and temperatures between room temperature and 450 °C. The run products were characterized by X-ray diffraction, and key microstructural parameters were extracted employing X-ray line profile analysis. The dominant slip system was determined as r { 10 1 bar 4 } ⟨ 2 bar 021 ⟩ with edge dislocation character. The resulting dislocation density and the size of the coherently scattering domains (CSD) exhibit a systematic dependence on the P-T conditions of deformation. While high pressure generally impedes recovery through reducing point defect mobility, the picture is complicated by pressure-induced phase transformations in the CaCO3 system. Transition from the calcite stability field to those of the high-pressure polymorphs CaCO3-II, CaCO3-III and CaCO3-IIIb leads to a change of the microstructural evolution with deformation. At 450 °C and pressures within the calcite stability field, dislocation densities and CSD sizes saturate at shear strains exceeding 10 in agreement with earlier studies at lower pressures. In the stability field of CaCO3-II, the dislocation density exhibits a more complex behavior. Furthermore, at a given strain and strain rate, the dislocation density increases and the CSD size decreases with increasing pressure within the stability fields of either calcite or of the high-pressure polymorphs. There is, however, a jump from high dislocation densities and small CSDs in the upper pressure region of the calcite stability field to lower dislocation densities and larger CSDs in the low-pressure region of the CaCO3-II stability field. This jump is more pronounced at higher temperatures and less so at room temperature. The pressure influence on the deformation-induced evolution of dislocation densities implies that pressure variations may change the rheology of carbonate rocks. In particular, a weakening is expected to occur at the transition from the calcite to the CaCO3-II stability field, if aragonite does not form.
Effect of body mass index on patients with multiligamentous knee injuries.
Ridley, T J; Cook, Shane; Bollier, Matthew; McCarthy, Mark; Gao, Yubo; Wolf, Brian; Amendola, Annunziato
2014-11-01
Our goal was to evaluate the impact of body mass index (BMI) on complications and associated injuries in patients undergoing surgical treatment for multiligamentous knee injuries (MLKIs). Over a period of 10 years, 126 MLKIs (123 patients) were included in the study. The inclusion criteria were (1) injury to 2 or more knee ligaments, (2) multiligament repair and/or reconstruction performed by 1 of 3 sports medicine orthopaedic surgeons at our institution, and (3) minimum of 1 year of follow-up. A chart review was performed to collect demographic data, mechanism of injury, ligaments involved, complications, and associated neurovascular injuries. Lastly, patients were divided by BMI into non-obese (<30 kg/m(2)) and obese (≥30 kg/m(2)) groups. Of the 126 MLKIs, 87 occurred in non-obese patients and 39 occurred in obese patients. Surgical complication rates for non-obese and obese patients were 8.05% and 15.4%, respectively (P = .21). Revisions were needed in 8.05% and 5.1% of patients in these groups, respectively (P = .72). Three wound complications were found in the obese group only. Vascular injuries were found in 2.3% and 7.7% of patients in the non-obese and obese groups, respectively (P = .17). The rates of nerve injuries were 11.49% and 20.51%, respectively (P = .18). Patients in the obese group were most likely to have an MLKI from low-energy mechanisms, disregarding sports-related injuries (51.28%, P = .02). Using a logistic model and BMI as a continuous variable, we found that a 1-unit increase in BMI increased the odds ratio of complications by 9.2%, with statistical significance (P = .0174). In addition, post hoc power analysis using previous literature showed that this study could produce satisfactory power. Our results indicate that (1) obese individuals are significantly more likely to have an MLKI caused by low-energy mechanisms and (2) complication rates increase by 9.2% for every 1-unit increase in BMI. Level III, retrospective comparative study. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy.
Hernigou, Philippe; Huys, Maxime; Pariat, Jacques; Roubineau, François; Flouzat Lachaniette, Charles Henri; Dubory, Arnaud
2018-02-01
There is no information comparing the results of fixed-bearing total knee replacement and mobile-bearing total knee replacement in the same patients previously treated by high tibial osteotomy. The purpose was therefore to compare fixed-bearing and mobile-bearing total knee replacements in patients treated with previous high tibial osteotomy. We compared the results of 57 patients with osteoarthritis who had received a fixed-bearing prosthesis after high tibial osteotomy with the results of 41 matched patients who had received a rotating platform after high tibial osteotomy. The match was made for length of follow-up period. The mean follow-up was 17 years (range, 15-20 years). The patients were assessed clinically and radiographically. The pre-operative knee scores had no statistically significant differences between the two groups. So was the case with the intra-operative releases, blood loss, thromboembolic complications and infection rates in either group. There was significant improvement in both groups of knees, and no significant difference was observed between the groups (i.e., fixed-bearing and mobile-bearing knees) for the mean Knee Society knee clinical score (95 and 92 points, respectively), or the Knee Society knee functional score (82 and 83 points, respectively) at the latest follow-up. However, the mean post-operative knee motion was higher for the fixed-bearing group (117° versus 110°). In the fixed-bearing group, one knee was revised because of periprosthetic fracture. In the rotating platform mobile-bearing group, one knee was revised because of aseptic loosening of the tibial component. The Kaplan-Meier survivorship for revision at ten years of follow-up was 95.2% for the fixed bearing prosthesis and 91.1% for the rotating platform mobile-bearing prosthesis. Although we did manage to detect significant differences mainly in clinical and radiographic results between the two groups, we found no superiority or inferiority of the mobile-bearing total knee prosthesis over the fixed-bearing total knee prosthesis for patients previously operated by high tibial osteotomy.
Rao, Allison J.; Erickson, Brandon J.; Cvetanovich, Gregory L.; Yanke, Adam B.; Bach, Bernard R.; Cole, Brian J.
2015-01-01
Meniscal tears are the most common knee injury, and partial meniscectomies are the most common orthopaedic surgical procedure. The injured meniscus has an impaired ability to distribute load and resist tibial translation. Partial or complete loss of the meniscus promotes early development of chondromalacia and osteoarthritis. The primary goal of treatment for meniscus-deficient knees is to provide symptomatic relief, ideally to delay advanced joint space narrowing, and ultimately, joint replacement. Surgical treatments, including meniscal allograft transplantation (MAT), high tibial osteotomy (HTO), and distal femoral osteotomy (DFO), are options that attempt to decrease the loads on the articular cartilage of the meniscus-deficient compartment by replacing meniscal tissue or altering joint alignment. Clinical and biomechanical studies have reported promising outcomes for MAT, HTO, and DFO in the postmeniscectomized knee. These procedures can be performed alone or in conjunction with ligament reconstruction or chondral procedures (reparative, restorative, or reconstructive) to optimize stability and longevity of the knee. Complications can include fracture, nonunion, patella baja, compartment syndrome, infection, and deep venous thrombosis. MAT, HTO, and DFO are effective options for young patients suffering from pain and functional limitations secondary to meniscal deficiency. PMID:26779547
Martin, J Ryan; Watts, Chad D; Levy, Daniel L; Miner, Todd M; Springer, Bryan D; Kim, Raymond H
2017-01-01
Stress shielding is an uncommon complication associated with primary total knee arthroplasty. Patients are frequently identified radiographically with minimal clinical symptoms. Very few studies have evaluated risk factors for postoperative medial tibial bone loss. We hypothesized that thicker cobalt-chromium tibial trays are associated with increased bone loss. We performed a retrospective review of 100 posterior stabilized, fixed-bearing total knee arthroplasty where 50 patients had a 4-mm-thick tibial tray (thick tray cohort) and 50 patients had a 2.7-mm-thick tibial tray (thin tray cohort). A clinical evaluation and a radiographic assessment of medial tibial bone loss were performed on both cohorts at a minimum of 2 years postoperatively. Mean medial tibial bone loss was significantly higher in the thick tray cohort (1.07 vs 0.16 mm; P = .0001). In addition, there were significantly more patients with medial tibial bone loss in the thick tray group compared with the thin tray group (44% vs 10%, P = .0002). Despite these differences, there were no statistically significant differences in range of motion, knee society score, complications, or revision surgeries performed. A thicker cobalt-chromium tray was associated with significantly more medial tibial bone loss. Despite these radiographic findings, we found no discernable differences in clinical outcomes in our patient cohort. Further study and longer follow-up are needed to understand the effects and clinical significance of medial tibial bone loss. Copyright © 2016 Elsevier Inc. All rights reserved.
Matsen, Frederick A; Stephens, Linda; Jette, Jocelyn L; Warme, Winston J; Posner, Karen L
2013-02-20
An orthopaedic malpractice claim alleges that the patient sustained a preventable iatrogenic injury. The analysis of a representative series of malpractice claims provides a unique view of alleged orthopaedic adverse events, revealing what can potentially go wrong across a spectrum of practice settings and anatomic locations. The goal of this study was to identify high-impact targets in order to institute measures to reduce claims through efforts focused on patient safety. The authors investigated 464 consecutive closed malpractice claims from the nation's largest insurer of medical liability. We analyzed the claims by anatomical site, type of care rendered, type of allegation, and payment. We calculated an "impact factor" for each claim type by dividing the percentage of total payments for each type by the percentage of total claims for that type. Our analysis revealed major concerns regarding patient safety within this series of malpractice claims. One-third of the claims alleged permanent disabling injuries, including amputations, brain damage, and major nerve damage. The highest impact allegations were failure to protect structures in the surgical field (41% of total payments to plaintiffs, 15% of all claims, impact factor of 2.7) and failure to prevent, diagnose, and/or treat complications of treatment (16% of total payments, 7% of all claims, impact factor of 2.3). Spine procedures had high impact (1.9), representing 28% of dollars paid and 15% of claims, with 45% of spine claims involving death or severe permanent injury. Failure of implant positioning was commonly alleged in hip and knee arthroplasty. In claims related to fracture care, the most common allegations were related to malunions, nonunions, dislocations, failure to protect structures in the surgical field, infection, and treatment complications. Total payment for the eighty-eight claims paid was $17,917,614 (U.S. dollars adjusted to 2009). Regarding clinical relevance, this analysis suggests risk areas for targeted efforts to improve patient safety and reduce malpractice claims.
Chen, Peng; Zeng, Min; Xie, Jie; Wang, Long; Su, Weiping; Hu, Yihe
2016-09-28
To investigate the clinical effect of total knee arthroplasty on patients with knee osteoarthritis combined with mild to moderate valgus knee deformity. A total of 15 patients received total knee arthroplasty for correcting mild (10°-15°) to moderate (15°-30°) valgus knee between January 2011 and February 2014 in Xiangya Hospital of Central South University. We adopted a stable prosthesis surgery through patellar medial approach, osteophytes cleaning, conventional osteotomy, a selective soft tissue release and balance technical correcting of knee valgus deformity. Then conventional anticoagulation and symptomatic rehabilitation was utilized. Preoperative and postoperative X-ray was conducted in patients with measuring femor-tibial angle (FTA) and inspecting the prosthesis position. FTA, visual analog scale (VAS) standard, and parallel knee scoring system (KSS) were used to evaluate the clinical effect. Fifteen patients were followed up for 14 to 36 (22.40±11.88) months. The hospitalization time was 7-13 (7.73±1.58) d; operative time was 58-110 (81.8±16.85) min, the dominant blood loss was 140-600 (337.30±143.65) mL. Two cases had knee extension hysteresis, and the knee activity recovered after exercise. Leg power lines were normal. Three postoperative cases suffered anterior knee pain. They were subjected to celecoxib analgesic treatment and the pain gradually eased after 3 months. One postoperative case showed incision discharge and swelling, which was healed after change of dressing. During follow-up, review of X-ray film does not show prosthesis loose, subsidence and other complications. The knee valgus angle (8.1±1.8)°, knee motion range (107.33±9.61)°, KSS knee score (74.7±14.5, 75.3±2.7) and pain score (2.5±0.9) were significantly better than the preoperative (P<0.05). The clinical and function KSS scores showed that the improvement rate was 80%. Total knee arthroplasty is an effective way to treat patients with knee osteoarthritis combined with mild to moderate valgus knee deformity. The correction of deformity and improvement of joint function can be achieved significantly. The clinical result is satisfactory and patients' quality of life is improved.
Position of the prosthesis and the incidence of dislocation following total hip replacement.
He, Rong-xin; Yan, Shi-gui; Wu, Li-dong; Wang, Xiang-hua; Dai, Xue-song
2007-07-05
Dislocation is the second most common complication of hip replacement surgery, and impact of the prosthesis is believed to be the fundamental reason. The present study employed Solidworks 2003 and MSC-Nastran software to analyze the three dimensional variables in order to investigate how to prevent dislocation following hip replacement surgery. Computed tomography (CT) imaging was used to collect femoral outline data and Solidworks 2003 software was used to construct the cup model with variabilities. Nastran software was used to evaluate dislocation at different prosthesis positions and different geometrical shapes. Three dimensional movement and results from finite element method were analyzed and the values of dislocation resistance index (DRI), range of motion to impingement (ROM-I), range of motion to dislocation (ROM-D) and peak resisting moment (PRM) were determined. Computer simulation was used to evaluate the range of motion of the hip joint at different prosthesis positions. Finite element analysis showed: (1) Increasing the ratio of head/neck increased the ROM-I values and moderately increased ROM-D and PRM values. Increasing the head size significantly increased PRM and to some extent ROM-I and ROM-D values, which suggested that there would be a greater likelihood of dislocation. (2) Increasing the anteversion angle increased the ROM-I, ROM-D, PRM, energy required for dislocation (ENERGY-D) and DRI values, which would increase the stability of the joint. (3) As the chamber angle was increased, ROM-I, ROM-D, PRM, Energy-D and DRI values were increased, resulting in improved joint stability. Chamber angles exceeding 55 degrees resulted in increases in ROM-I and ROM-D values, but decreases in PRM, Energy-D, and DRI values, which, in turn, increased the likelihood of dislocation. (4) The cup, which was reduced posteriorly, reduced ROM-I values (2.1 -- 5.3 degrees ) and increased the DRI value (0.073). This suggested that the posterior high side had the effect of 10 degrees anteversion angle. Increasing the head/neck ratio increases joint stability. Posterior high side reduced the range of motion of the joint but increased joint stability; Increasing the anteversion angle increases DRI values and thus improve joint stability; Increasing the chamber angle increases DRI values and improves joint stability. However, at angles exceeding 55 degrees , further increases in the chamber angle result in decreased DRI values and reduce the stability of the joint.
Davis, Aileen M; Venkataramanan, Viji; Bytautas-Sillanpää, Jessica; Perruccio, Anthony V; Wong, Rosalind; Carlesso, Lisa; Webster, Fiona
2017-08-18
The impact of the context of a person's life on recovery from surgical interventions is not well understood. This study evaluated if people's social, environmental and biomedical context was associated with change in frequency in engagement in life activities after total knee replacement (TKR). 418 people aged 30+ years who had TKR were followed presurgery to 1 year postsurgery. The outcome was change in frequency in engagement in life activities measured by the Late Life Disability Index (LLDI). Predictor variables of interest evaluated in multivariable linear regression analysis were positive and negative life events (Life Experiences Survey), development of a new comorbidity, another joint replacement and complications after TKR surgery. Mean age was 65 years, 36% were male; 22% and 21% had no comorbidity presurgery and postsurgery. Presurgery LLDI frequency was 69.6 (±11.4) and the mean change was 6.1 (±10.2). Thirty-four per cent and 65% reported at least one positive or negative life event. Seven per cent developed hypertension, 6% cardiovascular disease, 2% lung disease and 2% diabetes. Eleven per cent had a complication and 9% another hip or knee replaced. Smaller changes in LLDI frequency were associated with more negative life events (beta=-0.56; 95% CI -0.92 to-0.18) and complications (beta=-4.01; 95% CI -6.63 to -1.38) after adjusting for age, sex, education, body mass index, comorbidities presurgery, number of symptomatic joints and knee-specific pain and function, LLDI limitations and depression. A new comorbidity or another joint replacement was not associated with outcome in unadjusted or adjusted analysis. Multifaceted life experiences shape the context of peoples' lives impacting their engagement in activities important for healthy living post-TKR. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Complications in Hip Arthroscopy
Nakano, Naoki; Khanduja, Vikas
2016-01-01
Summary Background Recent developments in hip arthroscopic techniques and technology have made it possible in many cases to avoid open surgical dislocation for treating a variety of pathology in the hip. Although early reports suggest favourable results’ using hip arthroscopy and it has been shown to be a relatively safe procedure, complications do exist and can sometimes lead to significant morbidity. Methods This is a review article. The aim of this manuscript is to present the most frequent and/or serious complications that could occur at or following hip arthroscopy and some guidelines to avoid these complications. Conclusion Most complications of hip arthroscopy are minor or transient but serious complications can occur as well. A lot of complication e.g. acetabular labral puncture go unreported. Appropriate education and training, precise and meticulous surgical technique with correct instrumentation, the right indication in the right patient and adherence to advice from mentors and experienced colleagues are all essential factors for a successful outcome. Level of evidence: V. PMID:28066747
Röhner, Eric; Windisch, Christoph; Nuetzmann, Katy; Rau, Max; Arnhold, Michael; Matziolis, Georg
2015-01-01
Background: Periprosthetic infection is one of the most dreaded orthopaedic complications. Current treatment procedures include one-stage or two-stage revision total knee arthroplasty. If the periprosthetic infection is no longer controllable after several revision total knee arthroplasties, many surgeons regard knee arthrodesis as a promising option. The aim of our study was to ascertain whether intramedullary nailing results in the suppression or eradication of an infection and to identify risk factors for persistent infection. Methods: All patients who had undergone intramedullary nailing following septic failure of revision total knee arthroplasty between 1997 and 2013 were included in the study. Pathogens, risk factors predisposing to persistent infection, and the rate of persistent infections were recorded. In addition, a visual analog scale (VAS) and Knee injury Osteoarthritis Outcome Score (KOOS), Knee Society Score (KSS), Lysholm, Short Form-36 (SF-36), and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) questionnaires were completed to assess clinical outcomes and quality of life. Results: Twenty-six patients were included in the study. Thirteen (50%) had a persistent infection requiring additional revision surgery. Nineteen patients (73%) reported persistent pain (VAS score of >3). All scores showed marked impairment of quality of life. Conclusions: Intramedullary nailing following septic failure of revision total knee arthroplasty must be regarded with skepticism, and we cannot recommend it. Repeat revision total knee arthroplasty or amputation should be considered as an alternative in such difficult cases. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. PMID:25695981
Biomechanical effects of valgus knee bracing: a systematic review and meta-analysis.
Moyer, R F; Birmingham, T B; Bryant, D M; Giffin, J R; Marriott, K A; Leitch, K M
2015-02-01
To review and synthesize the biomechanical effects of valgus knee bracing for patients with medial knee osteoarthritis (OA). Electronic databases were searched from their inception to May 2014. Two reviewers independently determined study eligibility, rated study quality and extracted data. Where possible, data were combined into meta-analyses and pooled estimates with 95% confidence intervals (CI) for standardized mean differences (SMD) were calculated. Thirty studies were included with 478 subjects tested while using a valgus knee brace. Various biomechanical methods suggested valgus braces can decrease direct measures of medial knee compressive force, indirect measures representing the mediolateral distribution of load across the knee, quadriceps/hamstring and quadriceps/gastrocnemius co-contraction ratios, and increase medial joint space during gait. Meta-analysis from 17 studies suggested a statistically significant decrease in the external knee adduction moment (KAM) during walking, with a moderate-to-high effect size (SMD = 0.61; 95% CI: 0.39, 0.83; P < 0.001). Meta-regression identified a near-significant association for the KAM effect size and duration of brace use only (β, -0.01; 95% CI: -0.03, 0.0001; P = 0.06); with longer durations of brace use associated with smaller treatment effects. Minor complications were commonly reported during brace use and included slipping, discomfort and poor fit, blisters and skin irritation. Systematic review and meta-analysis suggests valgus knee braces can alter knee joint loads through a combination of mechanisms, with moderate-to-high effect sizes in biomechanical outcomes. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Newman, Jared M; Schiltz, Nicholas K; Mudd, Christopher D; Szubski, Caleb R; Klika, Alison K; Barsoum, Wael K
2016-11-01
Cirrhosis is a major cause of morbidity and mortality and is an important risk factor for complications in surgical patients. The purpose of this study was to investigate the association of cirrhosis with postoperative complications, length of stay (LOS), and costs among patients who underwent total knee arthroplasty (TKA) or total hip arthroplasty (THA). Using the Nationwide Inpatient Sample between 2000 and 2011, we identified patients who had a primary TKA or primary THA. TKA patients were divided into 2 groups: (1) cirrhosis (n = 41,464) and (2) no cirrhosis (n = 5,721,297) and THA patients were divided into 2 groups: (1) cirrhosis (n = 27,401) and (2) no cirrhosis (n = 2,622,539). Patient demographics, comorbidities, perioperative complications, LOS, and incremental costs were analyzed. An additional subgroup analysis by cirrhosis etiology was performed. Multivariable analysis revealed cirrhosis was associated with 1.55 (95% confidence interval: 1.47-1.63) times higher odds of any complication after TKA and 1.59 (1.50-1.69) higher odds after THA. Adjusted outcomes showed cirrhotic TKA patients had $1857 higher costs and 0.30 days longer LOS and THA cirrhotic patients had $1497 higher costs and 0.48 longer LOS. We found similar results for each cirrhosis subtype but alcohol-related had the highest resource use and complication rate. Patients with cirrhosis who are undergoing TKA or THA are at a significantly increased risk for perioperative complications, increased LOS, and higher costs. The perioperative complications and costs were highest among patients with alcohol-related cirrhosis. Copyright © 2016 Elsevier Inc. All rights reserved.
[Effect of posterior cruciate ligament retaining or not on knee-joint proprioception].
Wu, Yansheng; Li, Yongsheng; Chen, Baicheng
2013-07-01
To analyze the effect of the posterior cruciate ligament (PCL) retaining or not on knee-joint proprioception by comparing the proprioceptive difference between PCL retaining and no PCL retaining in total knee arthroplasty (TKA). Between June 2009 and June 2010, 38 osteoarthritis patients meeting the inclusion criteria were divided into PCL retaining group (group A, n=19) and PCL-substituting group (group B, n=19) according to the random number table. There was no significant difference in gender, age, disease duration, the range of motion of the knee between 2 groups (P > 0.05). The effectiveness and the knee-joint proprioception were separately assessed by the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) score and the passive angle reproduction test (30, 60, and 90 degrees of knee flexion) preoperatively and 12 months postoperatively. All incisons healed by first intention, without complications of infection, fracture, and deep vein thrombosis of lower limb. The patients were followed up 12-17 months (mean, 14.1 months). The knee function after operation was obviously improved when compared with preoperative one; significant differences were observed in the WOMAC scores and the results of passive angle reproduction test between at preoperation and at 12 months after operation (P < 0.05), but no significant difference was found between group A and group B (P > 0.05). Whether PCL retaining or not in TKA both can improve knee-joint proprioception, and no obvious difference between them.
Manipulation under anaesthesia versus low stretch device in poor range of motion after TKA.
Witvrouw, E; Bellemans, J; Victor, J
2013-12-01
The purpose of this study was to evaluate the effectiveness of two frequently used non-operative treatment techniques for a stiff knee after total knee arthroplasty. Sixty-four patients with a stiff knee after total knee arthroplasty (TKA) were randomized into a manipulation under anaesthesia group, or a low load stretch (stretch) group. The patients were followed up for 6 weeks and were evaluated for maximum flexion and extension, range of motion (ROM), pain, stiffness and function. Both groups showed a significant increase in knee flexion in this study. Only the stretch group showed a significant increase in extension ROM. In both groups, a significant increase in Western Ontario and McMaster Universities was observed. No significant difference was observed between both groups for the flexion or extension ROM, or for any of the pain, function or stiffness scores during this study. The results of this study showed that the stretch technique had equal or superior results concerning ROM and function compared to manipulation under anaesthesia. The stretch technique achieved this without requiring the patient to undergo in-hospital treatment or anaesthesia, limiting the costs and the risks for complications. The results of this study showed that stretching is a valuable tool for treating joint contractures of the knee. Therefore, the use of this stretching technique may be an excellent first choice of treatment modality in patients with slow progress of knee flexion or persistent knee stiffness following TKA, prior to manipulation under anaesthesia or lysis of adhesions.
Gekeler, Jörg
2007-10-01
AIMS OF DIAGNOSTIC RADIOGRAPHY: Visualization of the proximal femur in two clearly defined projections. Radiologic and morphological diagnosis of slipped capital femoral epiphysis. Evaluation of the stability of the femoral epiphysis: chronic slippage or acute interruption of continuity between the femoral epiphysis and the femoral neck metaphysis. Radiometric measurement of the spatial deformity of the femoral epiphysis. Measurement of the projected epiphyseal angle on the radiograph as the basis for possible conversion into anatomically correct angles at the proximal femur. Preoperative planning of therapeutic surgical procedures. Idiopathic hip pain in the growing child or adolescent. Referred pain to the knee or thigh. Unusual gait pattern with external rotation deformity of the leg, limping that favors one leg or limping due to leg length discrepancy. Abnormal sonography, CT or MRI findings. Eventful history including minor injury or genuine trauma. Symptoms and uncommon physical constitution: obesity, exceptional longitudinal growth of the extremities, and absence of secondary sex characteristics. Indications for Radiographic Imaging of the Hip Joint in Two Planes None. Standard positioning of the patient or the affected extremity. First standard radiograph: proximal femur in anteroposterior projection. Position of the leg with the patella directed anteriorly. Contraction of the external rotators at the hip joint is compensated by elevation of the hip until the leg is in the neutral position. Second standard radiograph: axial view of the proximal femur in anteroposterior projection. Leg flexed to 90 degrees at the hip and in 45 degrees abduction. Thigh position parallel to the longitudinal axis of the table (zero rotation). Early signs of incipient or imminent femoral epiphyseolysis: --Disintegration, widening and blurred margins of the epiphyseal plate. --Increasing loss of height of the femoral epiphysis due to incipient dislocation. --The tangent to the lateral femoral neck intersects only slightly with the femoral head or runs tangential to the epiphysis. --Important second radiograph in axial projection: incipient slippage is seen early here. Comparison with the contralateral side. Chronic slipped capital femoral epiphysis in adolescents: --Advanced epiphyseal dislocation visible in both planes. The tangent to the lateral femoral neck no longer intersects with the dislocated femoral epiphysis. In some cases, varus deformity of the femoral neck and periosteal elevation at the borders of the medial femoral neck. --Epiphyseal dislocation even more apparent in the axial view. Acute slipped capital femoral epiphysis in adolescents: --Complete interruption of continuity between epiphysis and metaphysis. --Widened gap between epiphysis and metaphysis. --Cystic irregularities of the metaphysis. --In most cases, substantial dislocation between epiphysis and metaphysis. --"Acute on chronic slip": specific type of acute epiphyseal dislocation subsequent to chronic epiphyseolysis. In addition to signs of acute separation, secondary symptoms of chronic epiphyseolysis such as femoral neck arcuation and spur formation at the head-neck junction. --Dynamic fluoroscopy may be indicated to confirm acute dislocation. Defined axes are marked on the radiograph: anatomic axis of the femur, femoral neck axis, and so-called epiphyseal axis (perpendicular to the base of the epiphysis). Measurement of the projected epiphysis-diaphysis angle (ED' angle) on the anteroposterior radiograph and the projected epiphyseal torsion angle (ET' angle) on the axial radiograph. For slight to moderate slippage, the difference between the epiphyseal dislocation angle obtained from the radiographs (as projected in two planes) compared with the anatomic, i.e., real dislocation angle at the proximal femur is generally relatively minor. Conversion of the projected angle to the real angle is not essential in these cases (if in doubt, see Table 1). For more severe dislocations, the differences between the projected and real angles are far more apparent. Table 1 facilitates conversion of the epiphyseal dislocation angles taken from the radiograph into anatomically correct dislocation angles at the proximal femur. Conversion to real angles, especially for preoperative planning of complex corrective surgery, is indicated for more severe deformities of the femoral epiphysis. Conversion into real (anatomic) angles is indicated for exact prognostic evaluation of prearthrotic deformities.
Emerson, Roger H; Barrington, John W; Olugbode, Seun A; Alnachoukati, Omar K
2016-02-01
Frequently, a normal posterior-cruciate ligament (PCL) is removed at the surgeon's discretion, converting the normal 4-ligament knee to a 2-ligament knee, thus eliminating the need to balance all 4 ligaments. The development of modular tibial components has led to the availability of differing polyethylene inserts that permit adjustment to the flexion gap independent of the extension gap, permitting PCL balancing not previously available. The purpose of this study is to analyze a specific cruciate-retaining (CR) prosthesis which has 2 polyethylene inserts intended for CR knee use. Between February 2004 and February 2013, the senior author (R.H.E.) has performed 930 total knee arthroplasties using the CR flat insert and 424 knees using the CR lipped insert. The inserts were selected during surgery, based on the assessed tension and function of the PCL. The patients were followed up as part of a prospective total joint program with the Knee Society clinical scoring, range of motion, complications, revisions, preoperative coronal deformity, gender, body mass index, and status of the anterior-cruciate ligament intraoperatively. The average Knee Score was 92.4 for the flat group and 92.1 for the lipped group. Average knee flexion was 116.2° for the flat group and 114.4° for the lipped group (P=.2). Average knee extension (flexion deformity) was 2.1° for the flat group and 0.9° for the lipped group The results reported here show that clinical outcomes and survivorship were no different for either insert option, leading to indirect evidence that appropriate soft tissue balance had been achieved. Published by Elsevier Inc.