Hu, Chen; Wang, Feng; Yang, Huiyong; Ai, Jun; Wang, Linlin; Jing, Dongdong; Shao, Longquan; Zhou, Xingui
2014-12-01
Currently used fibre-reinforced composite (FRC) intracanal posts possess low flexural strength which usually causes post fracture when restoring teeth with extensive loss. To improve the flexural strength of FRC, we aimed to apply a high-performance fibre, poly p-phenylene-2, 6-benzobisoxazole (PBO), to FRCs to develop a new intracanal post material. To improve the interfacial adhesion strength, the PBO fibre was treated with coupling agent (Z-6040), argon plasma, or a combination of above two methods. The effects of the surface modifications on PBO fibre were characterised by determining the single fibre tensile strength and interfacial shear strength (IFSS). The mechanical properties of PBO FRCs were characterised by flexural strength and flexural modulus. The cytotoxicity of PBO FRC was evaluated by the MTT assay. Fibres treated with a combination of Z-6040 and argon plasma possessed a significantly higher IFSS than untreated fibres. Fibre treated with the combination of Z-6040-argon-plasma FRC had the best flexural strength (531.51 ± 26.43MPa) among all treated fibre FRCs and had sufficient flexural strength and appropriate flexural moduli to be used as intracanal post material. Furthermore, an in vitro cytotoxicity assay confirmed that PBO FRCs possessed an acceptable level of cytotoxicity. In summary, our study verified the feasibility of using PBO FRC composites as new intracanal post material. Although the mechanical property of PBO FRC still has room for improvement, our study provides a new avenue for intracanal post material development in the future. To our knowledge, this is the first study to verify the feasibility of using PBO FRC composites as new intracanal post material. Our study provided a new option for intracanal post material development. Copyright © 2014 Elsevier Ltd. All rights reserved.
Kathuria, Ambica; Kavitha, M; Khetarpal, Suchit
2011-01-01
Aim: To compare the fracture resistance of teeth restored with fiber-reinforced composite (FRC) posts and experimental dentin posts milled from human root dentin. Materials and Methods: Thirty maxillary central incisors were divided into three groups of ten each. Twenty teeth were restored with FRC posts and solid dentin posts and numbered as Groups 2 and 3 respectively while Group 1 acted as the control, without any post. The teeth were loaded at 135° angle to their long axes after core build-up and the failure loads were recorded. Results: One-way Analysis of Variance (ANOVA) and Bonferroni multiple comparisons revealed a significant difference among test groups with the control group showing the highest fracture resistance, followed by the dentin post group and lastly the FRC post group. Conclusions: Teeth restored with dentin posts exhibited better fracture resistance than those restored with FRC posts. PMID:22144812
Bonding of fibre-reinforced composite post to root canal dentin.
Bell, Anna-Maria Le; Lassila, Lippo V J; Kangasniemi, Ilkka; Vallittu, Pekka K
2005-08-01
The aim of this study was to determine bonding properties of two types of fibre-reinforced composite (FRC) posts cemented into root canals of molars. Serrated titanium posts served as reference. Prefabricated carbon/graphite FRC posts with cross-linked polymer matrix and individually formed glass FRC posts with interpenetrating polymer network (IPN) polymer matrix were compared. The crowns of extracted third molars were removed and post space (diameter: 1.5mm) was drilled, etched and bonded. The posts were treated with dimethacrylate adhesive resin, light-polymerized and cemented with a dual-polymerizing composite resin luting cement. After thermocycling (6000x) the samples were cut into discs of thicknesses: 1, 2 and 4mm (n=12/group). Push-out force was measured by pushing the post from one end. Assessment of failure mode was made under a stereomicroscope (1, adhesive failure between post and cement; 2, cohesive failure of post-system; 3, adhesive failure between cement and dentin). The push-out force increased with increased height of dentin disc in all groups (ANOVA, p<0.001). In the 4mm thick dentin discs the individually formed glass FRC posts showed highest push-out force and the difference to that of the titanium posts was significant (ANOVA, p<0.001). The other differences were not statistically significant. None of the individually formed glass FRC posts showed adhesive failures between the post and the cement. Contrary to the other posts, there were no adhesive (post-cement) failures with the individually formed glass FRC posts, suggesting better interfacial adhesion of cement to these posts.
Asakawa, Yuya; Takahashi, Hidekazu; Iwasaki, Naohiko; Kobayashi, Masahiro
2014-01-01
The aim of the present study was to characterize the effects of the ultraviolet light (UV) irradiation period on the bond strength of fiber-reinforced composite (FRC) posts to core build-up resin. Three types of FRC posts were prepared using polymethyl methacrylate, urethane dimethacrylate, and epoxy resin. The surfaces of these posts were treated using UV irradiation at a distance of 15 mm for 0 to 600 s. The pull-out bond strength was measured and analyzed with the Dunnett's comparison test (α=0.05). The bond strengths of the post surfaces without irradiation were 6.9 to 7.4 MPa; those after irradiation were 4.2 to 26.1 MPa. The bond strengths significantly increased after 15 to 120-s irradiation. UV irradiation on the FRC posts improved the bond strengths between the FRC posts and core build-up resin regardless of the type of matrix resin.
Creep and dynamic viscoelastic behavior of endodontic fiber-reinforced composite posts.
Papadogiannis, D; Lakes, R S; Palaghias, G; Papadogiannis, Y
2009-10-01
Fiber-reinforced composite (FRC) posts have gained much interest recently and understanding of their viscoelastic properties is important as they can be used in stress-bearing posterior restorations. The aim of this study was to evaluate the creep behavior and the viscoelastic properties of four commercial FRC posts under different temperatures and different storage conditions. The FRC posts tested were Glassix, C-Post, Carbonite and Snowlight. For the creep measurements a constant load below the proportional limit of the posts was applied and the angular deformation of the specimens was recorded. The viscoelastic parameters were determined by using dynamic torsional loading under four different conditions. All materials were susceptible to creep and exhibited linear viscoelastic behavior. Residual strain was observed in all FRC posts. The viscoelastic properties were affected by the increase of temperature and water storage (p<0.001) resulting in their decline. Carbon fiber posts exhibited better performance than glass fiber posts. FRC posts exhibit permanent strains under regular masticatory stresses that can be generated in the oral cavity. Their properties are susceptible to changes in temperature, while direct contact with water also affects them deleteriously.
Stewardson, D; Shortall, A; Marquis, P
2012-01-01
To investigate the bond of endodontic post materials, with and without grit blasting, to a resin composite cement and a core material using push-out bond strength tests. Fiber-reinforced composite (FRC) posts containing carbon (C) or glass (A) fiber and a steel (S) post were cemented into cylinders of polymerized restorative composite without surface treatment (as controls) and after grit blasting for 8, 16, and 32 seconds. Additional steel post samples were sputter-coated with gold before cementation to prevent chemical interaction with the cement. Cylindrical composite cores were bonded to other samples. After sectioning into discs, bond strengths were determined using push-out testing. Profilometry and electron microscopy were used to assess the effect of grit blasting on surface topography. Mean (standard deviation) bond strength values (MPa) for untreated posts to resin cement were 8.41 (2.80) for C, 9.61(1.88) for A, and 19.90 (3.61) for S. Prolonged grit blasting increased bond strength for FRC posts but produced only a minimal increase for S. After 32 seconds, mean values were 20.65 (4.91) for C, 20.41 (2.93) for A, and 22.97 (2.87) for S. Gold-coated steel samples produced the lowest bond strength value, 7.84 (1.40). Mean bond strengths for untreated posts bonded to composite cores were 6.19 (0.95) for C, 13.22 (1.61) for A, and 8.82 (1.18) for S, and after 32 seconds of grit blasting the values were 17.30 (2.02) for C, 26.47 (3.09) for A, and 20.61 (2.67) for S. FRC materials recorded higher roughness values before and after grit blasting than S. With prolonged grit blasting, roughness increased for A and C, but not for S. There was no evidence of significant bonding to untreated FRC posts, but significant bonding occurred between untreated steel posts and the resin cement. Increases in the roughness of FRC samples were material dependent and roughening significantly increased bond strength values (p<0.05). Surface roughening of the tested FRC posts is required for effective bonding.
Asakawa, Yuya; Takahashi, Hidekazu; Kobayashi, Masahiro; Iwasaki, Naohiko
2013-10-01
The aim of this study was to clarify the effect of the components and surface treatments of fiber-reinforced composite (FRC) posts on the durable bonding to core build-up resin evaluated using the pull-out and microtensile tests. Four types of experimental FRC posts, combinations of two types of matrix resins (polymethyl methacrylate and urethane dimethacrylate) and two types of fiberglass (E-glass and zirconia-containing glass) were examined. The FRC posts were subjected to one of three surface treatments (cleaned with ethanol, dichloromethane, or sandblasting). The bond strength between the FRC posts and core build-up resin were measured using the pull-out and microtensile tests before and after thermal cycling. The bond strengths obtained by each test before and after thermal cycling were statistically analyzed by three-way ANOVA and Tukey's multiple comparisons test (p<0.05). The bond strengths except for UDMA by the pull-out test decreased after thermal cycling. Regardless the test method and thermal cycling, matrix resins, the surface treatment and their interaction were statistically significant, but fiberglass did not. Dichloromethane treatment was effective for the PMMA-based FRC posts by the pull-out test, but not by the microtensile test. Sandblasting was effective for both PMMA- and UDMA-based FRC posts, regardless of the test method. The bond strengths were influenced by the matrix resin of the FRC post and the surface treatment. The bond strengths of the pull-out test showed a similar tendency of those of the microtensile test, but the value obtained by these test were different. Copyright © 2013 Elsevier Ltd. All rights reserved.
Ohtonen, J; Vallittu, P K; Lassila, L V J
2013-02-01
To compare force levels obtained from glass fibre-reinforced composite (FRC) archwires. Specifically, FRC wires were compared with polymer matrices having different dimethacrylate monomer compositions. FRC material (E-glass provided by Stick Tech Ltd, Turku, Finland) with continuous unidirectional glass fibres and four different types of dimethacrylate monomer compositions for the resin matrix were tested. Cross-sectionally round FRC archwires fitting into the 0.3 mm slot of a bracket were divided into 16 groups with six specimens in each group. Glass fibres were impregnated by the manufacturer, and they were initially light-cured by hand light-curing unit or additionally post-cured in light-curing oven. The FRC archwire specimens were tested at 37°C according to a three-point bending test in dry and wet conditions using a span length of 10 mm and a crosshead speed of 1.0 mm/minute. The wires were loaded until final failure. The data were statistically analysed using analysis of variance (ANOVA). The dry FRC archwire specimens revealed higher load values than water stored ones, regardless of the polymer matrix. A majority of the FRC archwires showed higher load values after being post-cured. ANOVA revealed that the polymer matrix, curing method, and water storage had a significant effect (P < 0.05) on the flexural behaviour of the FRC archwire. Polymer matrix composition, curing method, and water storage affected the flexural properties and thus, force level and working range which could be obtained from the FRC archwire.
Flexural properties of three kinds of experimental fiber-reinforced composite posts.
Kim, Mi-Joo; Jung, Won-Chang; Oh, Seunghan; Hattori, Masayuki; Yoshinari, Masao; Kawada, Eiji; Oda, Yutaka; Bae, Ji-Myung
2011-01-01
The aim of this study was to estimate the flexural properties of three kinds of experimental fiber-reinforced composite (FRC) posts and to evaluate their potential use as posts. Experimental FRC posts were fabricated with glass, aramid, and UHMWP fibers. Commercial FRC posts were used for comparison. A three-point bending test was performed at a crosshead speed of 1 mm/min. Experimental glass fiber posts showed significantly higher flexural strengths and moduli than aramid and UHMWP posts. Experimental UHMWP posts demonstrated superior toughness to the commercial posts. The glass fiber posts displayed stiff, strong and brittle features, while the UHMWP posts were flexible, weak and ductile. The flexural properties of the aramid posts fell between those of the glass and UHMWP posts. In conclusion, the glass fiber posts proved excellent in flexural strengths and moduli. However, the superior toughness of UHMWP fibers suggests the possibility of their use as posts in combination with glass fibers.
Fokkinga, Wietske A; Kreulen, Cees M; Vallittu, Pekka K; Creugers, Nico H J
2004-01-01
This study sought to aggregate literature data on in vitro failure loads and failure modes of prefabricated fiber-reinforced composite (FRC) post systems and to compare them to those of prefabricated metal, custom-cast, and ceramic post systems. The literature was searched using MEDLINE from 1984 to 2003 for dental articles in English. Keywords used were (post or core or buildup or dowel) and (teeth or tooth). Additional inclusion/exclusion steps were conducted, each step by two independent readers: (1) Abstracts describing post-and-core techniques to reconstruct endodontically treated teeth and their mechanical and physical characteristics were included (descriptive studies or reviews were excluded); (2) articles that included FRC post systems were selected; (3) in vitro studies, single-rooted human teeth, prefabricated FRC posts, and composite as the core material were the selection criteria; and (4) failure loads and modes were extracted from the selected papers, and failure modes were dichotomized (distinction was made between "favorable failures," defined as reparable failures, and "unfavorable failures,"defined as irreparable [root] fractures). The literature search revealed 1,984 abstracts. Included were 244, 42, and 12 articles in the first, second, and third selection steps, respectively. Custom-cast post systems showed higher failure loads than prefabricated FRC post systems, whereas ceramic showed lower failure loads. Significantly more favorable failures occurred with prefabricated FRC post systems than with prefabricated and custom-cast metal post systems. The variable "post system" had a significant effect on mean failure loads. FRC post systems more frequently showed favorable failure modes than did metal post systems.
Flexural properties of fiber reinforced root canal posts.
Lassila, Lippo V J; Tanner, Johanna; Le Bell, Anna-Maria; Narva, Katja; Vallittu, Pekka K
2004-01-01
Fiber-reinforced composite (FRC) root canal posts have been introduced to be used instead of metal alloys and ceramics. The aim of this study was to investigate the flexural properties of different types of FRC posts and compare those values with a novel FRC material for dental applications. Seventeen different FRC posts of various brands (Snowpost, Carbopost, Parapost, C-post, Glassix, Carbonite) and diameters, (1.0-2.1 mm) and a continuous unidirectional E-glass FRC polymerized by light activation to a cylindrical form (everStick, diameter 1.5 mm) as a control material were tested. The posts (n=5) were stored at room's humidity or thermocycled (12.000 x, 5 degrees C/55 degrees C) and stored in water for 2 weeks before testing. A three-point bending test (span=10 mm) was used to measure the flexural strength and modulus of FRC post specimens. Analysis of ANOVA revealed that thermocycling, brand of material and diameter of specimen had a significant effect (p<0.001) on the fracture load and flexural strength. The highest flexural strength was obtained with the control material (everStick, 1144.9+/-99.9 MPa). There was a linear relationship between fracture load and diameter of posts for both glass fiber and carbon fiber posts. Thermocycling decreased the flexural modulus of the tested specimens by approximately 10%. Strength and fracture load decreased approximately 18% as a result of thermocycling. Considerable variation can be found in the calculated strength values of the studied post brands. Commercial prefabricated FRC posts showed lower flexural properties than an individually polymerised FRC material.
The flexural properties of endodontic post materials.
Stewardson, Dominic A; Shortall, Adrian C; Marquis, Peter M; Lumley, Philip J
2010-08-01
To measure the flexural strengths and moduli of endodontic post materials and to assess the effect on the calculated flexural properties of varying the diameter/length (D/L) ratio of three-point bend test samples. Three-point bend testing of samples of 2mm diameter metal and fiber-reinforced composite (FRC) rods was carried out and the mechanical properties calculated at support widths of 16 mm, 32 mm and 64 mm. Weibull analysis was performed on the strength data. The flexural strengths of all the FRC post materials exceeded the yield strengths of the gold and stainless steel samples; the flexural strengths of two FRC materials were comparable with the yield strength of titanium. Stainless steel recorded the highest flexural modulus while the titanium and the two carbon fiber materials exhibited similar values just exceeding that of gold. The remaining glass fiber materials were of lower modulus within the range of 41-57 GPa. Weibull modulus values for the FRC materials ranged from 16.77 to 30.09. Decreasing the L/D ratio produced a marked decrease in flexural modulus for all materials. The flexural strengths of FRC endodontic post materials as new generally exceed the yield strengths of metals from which endodontic posts are made. The high Weibull modulus values suggest good clinical reliability of FRC posts. The flexural modulus values of the tested posts were from 2-6 times (FRC) to 4-10 times (metal) that of dentin. Valid measurement of flexural properties of endodontic post materials requires that test samples have appropriate L/D ratios. Copyright 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Makarewicz, Dominika; Le Bell-Rönnlöf, Anna-Maria B; Lassila, Lippo V.J.; Vallittu, Pekka K.
2013-01-01
Objectives: The aim of this study was to evaluate the effect of two different cementation techniques of individually formed E-glass fiber-reinforced composite (FRC) post on bond strength and microleakage. Methods: The crowns of extracted third molars were removed and post preparation was carried out with parapost drills (diameter 1.5 mm). After application of bonding agents individually formed FRC posts (everStick POST, diameter 1.5 mm) were cemented into the post spaces with either ParaCem®Universal or self-adhesive RelyX™Unicem, using two different cementation techniques: 1) an “indirect (traditional) technique” where the post was prepolymerized prior application of luting cement and insertion into the post space or 2) a “direct technique” where the uncured post was inserted to the post space with luting cement and light-polymerized in situ at the same time. After water storage of 48 hours, the roots (n = 10/group) were cut into discs of thickness of 2 mm. A push-out force was applied until specimen fracture or loosening of the post. A microleakage test was carried out on roots which were not subjected to the loading test (n= 32) to evaluate the sealing capacity of the post-canal interface. The microleakage was measured using dye penetration depth under a stereomicroscope. Results: Higher bond strength values (p<0.05) and less microleakage (p<0.05) were obtained with the “direct technique” compared to the “indirect technique”. None of the FRC posts revealed any dye penetration between the post and the cement. Conclusions: The “direct technique” seems to be beneficial when cementing individually formed FRC posts. PMID:23986792
Helal, Mohammed Abu; Wang, Zhigang
2017-10-25
To compare equivalent and contact stresses in a mandibular molar restored by all-ceramic crowns through two methods: ceramic endocrowns and ceramic crowns supported by fiber-reinforced composite (FRC) posts and core, by using 3D finite element analysis during normal masticatory load. Three 3D models of a mandibular first molar were made and labeled as such: intact molar with no restoration (A); ceramic endocrown-restored molar (B); ceramic crown supported by FRC posts and core restored molar (C). By using 3D FE analysis with contact components, normal masticatory load was simulated. The mvM stresses in all models were calculated. Maximal mvM stresses in the ceramic of restorations, dentin, and luting cement were contrasted among models and to values of materials' strength. Contact shear and tensile stresses in the restoration/tooth interface around restorations were also calculated. The highest mvM stress levels in the enamel and dentin for the tooth restored by ceramic endocrown were lower in the crown ceramic than in tooth restored with FRC posts and all-ceramic crowns; however, in the resin adhesive cement interface it was lower for ceramic crown supported by FRC posts than the in ceramic endocrown restoration. The maximum contact shear and tensile stress values along the restoration/tooth interface of ceramic endocrowns were lower than those with ceramic crowns supported by FRC posts. Ceramic endocrown restorations presented a lower mvM stress level in dentin than the conventional ceramic crowns supported by FRC posts and core. Ceramic endocrown restorations in molars are less susceptible to damage than those with conventional ceramic crowns retained by FRC posts. Ceramic endocrowns properly cemented in molars must not be fractured or loosen during normal masticatory load. Therefore, ceramic endocrowns are advised as practicable, minimally invasive, and esthetic restorations for root canal treated mandibular molars. © 2017 by the American College of Prosthodontists.
Garoushi, Sufyan K; Lassila, Lippo V J; Tezvergil, Arzu; Vallittu, Pekka K
2006-09-01
The aim of this study was to determine the static load-bearing capacity of composite resin onlay restorations made of particulate filler composite (PFC) with two different types of fiber-reinforced composite (FRC) substructures. In addition, flexural properties of the material combination and the effect of polymerization devices were tested. Specimens were prepared to simulate an onlay restoration, which consisted of 2 to 3 mm of FRC layer as a substructure (short random and continuous bidirectional fiber orientation) and a 1 mm surface layer of PFC. Control specimens were prepared from plain PFC. In Group A the specimens were incrementally polymerized only with a hand-light curing unit for 40 s, while in Group B the specimens were post-cured in a light-curing oven for 15 min before they were statically loaded with a steel ball. Bar-shaped test specimens were prepared to measure the flexural properties of material combination using a three-point bending test (ISO 10477). Analysis of variance (ANOVA) revealed all specimens with a FRC substructure have higher values of static load-bearing capacity and flexural properties than those obtained with plain PFC (p<0.001). The load-bearing capacity of all the specimens decreased after post-curing and water storage. Restorations made from a material combination of FRC and PFC showed better mechanical properties than those obtained with plain PFC.
Fráter, Mark; Forster, András; Jantyik, Ádám; Braunitzer, Gábor; Nagy, Katalin
2015-12-01
The purpose of this in vitro investigation was to evaluate the reinforcing effect of different fibre-reinforced composite (FRC) posts and insertion techniques in premolar teeth when using minimal invasive post space preparation. Thirty two extracted and endodontically treated premolar teeth were used and divided into four groups (n = 8) depending on the post used (Group 1-4). 1: one single conventional post, 2: one main conventional and one collateral post, 3: one flexible post, 4: one main flexible and one collateral post. After cementation and core build-up the specimens were submitted to static fracture toughness test. Fracture thresholds and fracture patterns were recorded and evaluated. The multi-post techniques (group 2 and 4) showed statistically higher fracture resistance compared to group one. Regarding fracture patterns there was no statistically significant difference between the tested groups. The application of multiple posts seems to be beneficial regarding fracture resistance independent from the used FRC post. Fracture pattern was not influenced by the elasticity of the post.
Wang, Hsuan-Wen; Chang, Yen-Hsiang; Lin, Chun-Li
2017-01-01
This study evaluates the fracture resistance in an endodontically treated tooth using circular fiber-reinforced composite (FRC) and innovated anatomical short glass fiber reinforced (SGFR) posts under fatigue testing, monitored using the acoustic emission (AE) technique. An anatomical SGFR fiber post with an oval shape and slot/notch design was manufactured using an injection-molding machine. Crown/core maxillary second premolar restorations were executed using the anatomical SGFR and commercial cylindrical fiber posts under fatigue test to understand the mechanical resistances. The load versus AE signals in the fracture and fatigue tests were recorded to evaluate the restored tooth failure resistance. The static fracture resistance results showed that teeth restored using the anatomical SGFR post presented higher resistance than teeth restored using the commercial FRC post. The fatigue test endurance limitation (1.2×10 6 cycles) was 207.1N for the anatomical SGFR fiber post, higher than the 185.3N found with the commercial FRC post. The average accumulated number of AE signals and corresponding micro cracks for the anatomical SGFR fiber post (153.0 hits and 2.44 cracks) were significantly lower than those for the commercial FRC post (194.7 hits and 4.78 cracks) under 40% of the static maximum resistance fatigue test load (pass 1.2×10 6 cycles). This study concluded that the anatomical SGFR fiber post with surface slot/notch design made using precise injection molding presented superior static fracture resistance and fatigue endurance limitation than those for the commercial FRC post in an endodontically treated premolar. Copyright © 2016 Elsevier Ltd. All rights reserved.
[Fiber reinforced composite posts: literature review].
Frydman, G; Levatovsky, S; Pilo, R
2013-07-01
FRC (Fiber-reinforced composite) posts have been used since the beginning of the 90s with the introduction of carbon fiber posts. Fiber posts are widely used to restore endodontically treated teeth that have insufficient coronal tooth structure. Many in vitro and in vivo studies have shown the advantage of using FRC over prefabricated and cast metal post especially indicated in narrow root canals which are prone to vertically root fracture. The most frequent failure of FRC is debonding of a post at the resin cement/dentin interface. Bonding to dentin may be achieved by using etch-and-rinse and self-etch adhesives. The bond strength formed by self-adhesive cements is noticeably lower in comparison to the bond strength formed with resin cements applied in combination with etch-and-rinse adhesives. In an attempt to maximize resin bonding to fiber posts, several surface treatments have been suggested. Sandblasting with alumina particles results in an increased surface roughness and surface area without affecting the integrity of the post as long as it is applied by 50 microm alumina particles at 2.5 bars for maximally 5 seconds at a distance of 30 mm. The efficiency of post salinization is controversial and its contribution to the retention is of minor importance. Hydrofluoric acid has recently been proposed for etching glass fiber posts but this technique produced substantial damage to the glass fibers and affected the integrity of the post. Delayed cementation of fiber post (at least 24h post endodontic treatment) resulted in higher retentive strengths in comparison to immediate cementation and the best results were obtained when the luting agent was brought into the post space with lentulo spirals or specific syringes. The resin cement film thickness also influences the pullout strengths of fiber-reinforced posts .The highest bond strength values were obtained when the cement layer oversized the post spaces but not larger than 0.3 mm. The use of core build-up materials as post luting cements is not recommended. The use of FRC post, combined with proper adhesive cementation technique can give an excellent solution when restoring endodontically treated teeth that are prone to fracture.
Retrospective study of combined splinting restorations in the aesthetic zone of periodontal patients
Liu, X.; Zhang, Y.; Zhou, Z.; Ma, S.
2016-01-01
Aims This retrospective study evaluated the clinical performance of combining a fiber-reinforced, composite-resin (FRC) bonded splint; bridge; fiber post; and/or resin veneer for the restoration of periodontally-involved anterior teeth. Methods Sixty-three patients with periodontally-involved anterior teeth each received one of the following splinting restorations: FRC-bonded splint-bridges (SB), a combination of an FRC-bonded splint and resin veneer (SV), or FRC-bonded splints (S). Six patients with healthy periodontal teeth received orthodontic retainers with FRC-bonded splints (OS) as a control. Modified USPHS criteria were used to evaluate the effects of rehabilitation, and the periodontal pocket depth (PPD) and clinical attachment level (CAL) of the natural teeth were measured. Results All restorations resulted in good aesthetic outcomes. SV, S in combination with fiber posts and OS all resulted in 100% acceptable ratings for each category that was directly evaluated at each follow-up. The mean PPD was 3.5 ± 1.0 mm at baseline, decreased to 3.3 ± 1.0 mm after one year (p <0.05), and subsequently increased to 3.5±1.0 mm again after four years (p >0.05). These changes were similar to those in the mean CAL. Conclusion A combination of a FRC-bonded splint, bridge, fiber post and/or resin veneer for minimally invasive prosthodontic treatment in the aesthetic zone is a good choice for periodontal patients. PMID:26964599
Bone attachment to glass-fibre-reinforced composite implant with porous surface.
Mattila, R H; Laurila, P; Rekola, J; Gunn, J; Lassila, L V J; Mäntylä, T; Aho, A J; Vallittu, P K
2009-06-01
A method has recently been developed for producing fibre-reinforced composites (FRC) with porous surfaces, intended for use as load-bearing orthopaedic implants. This study focuses on evaluation of the bone-bonding behaviour of FRC implants. Three types of cylindrical implants, i.e. FRC implants with a porous surface, solid polymethyl methacrylate (PMMA) implants and titanium (Ti) implants, were inserted in a transverse direction into the intercondular trabeculous bone area of distal femurs and proximal tibias of New Zealand White rabbits. Animals were sacrificed at 3, 6 and 12 weeks post operation, and push-out tests (n=5-6 per implant type per time point) were then carried out. At 12 weeks the shear force at the porous FRC-bone interface was significantly higher (283.3+/-55.3N) than the shear force at interfaces of solid PMMA/bone (14.4+/-11.0 N; p<0.001) and Ti/bone (130.6+/-22.2N; p=0.001). Histological observation revealed new bone growth into the porous surface structure of FRC implants. Solid PMMA and Ti implants were encapsulated mostly with fibrous connective tissue. Finite element analysis (FEA) revealed that porous FRC implants had mechanical properties which could be tailored to smooth the shear stress distribution at the bone-implant interface and reduce the stress-shielding effect.
Stewardson, Dominic A; Shortall, Adrian C; Marquis, Peter M
2010-05-01
It is suggested that fibre-reinforced composite (FRC) posts have lower elastic moduli than metal posts and this will reduce the incidence of root fracture. However, the mechanical properties may be altered in the oral environment. The aims of this study were to determine the effect on the flexural properties of FRC and metal post materials produced by: (1) a thermocycling regime which was clinically relevant and representative of that which would occur during 1 year in the mouth and (2) storage for 1 year at body temperature. Nine FRC and two metal post material samples were sealed in polythene sleeves and thermocycled between 10 degrees C and 50 degrees C for 10,000 cycles. Additional samples were stored dry at 37 degrees C for 1 year. The flexural strength and moduli were determined by three-point bending and compared with untreated control samples. Thermocycling and storage at 37 degrees C for 1 year decreased the mean flexural modulus of all materials. This was statistically significant for 8 of 11 materials after thermocycling, and 4 of 11 materials after storage at 37 degrees C (p<0.05). Thermocycling and storage at 37 degrees C produced a non-significant increase in yield strength for both metal post materials. Thermocycling significantly increased the flexural strength of Postec while it decreased for the other FRC materials. Storage at 37 degrees C increased the flexural strength of three FRC materials (significantly for Postec) while it was decreased among the other materials. Although some of the changes noticed in flexural properties were statistically significant, it is doubtful that they are of sufficient magnitude to affect clinical performance.
Dejak, Beata; Młotkowski, Andrzej
2013-12-01
The objective was to compare equivalent stresses in molars restored with endocrowns as well as posts and cores during masticatory simulation using finite element analysis. Four three-dimensional models of first mandibular molars were created: A - intact tooth; B - tooth restored by ceramic endocrown; C - tooth with FRC posts, composite core and ceramic crown; D - tooth with cast post and ceramic crown. The study was performed using finite element analysis, with contact elements. The computer simulations of mastication were conducted. The equivalent stresses of modified von Mises failure criterion (mvM) in models were calculated, Tsai-Wu index for FRC post was determinate. Maximal values of the stresses in the ceramic, cement and dentin were compared between models and to strength of the materials. Contact stresses in the cement-tissue adhesive interface around restorations were considered as well. During masticatory simulation, the lowest mvM stresses in dentin arisen in molar restored with endocrown (Model B). Maximal mvM stress values in structures of restored molar were 23% lower than in the intact tooth. The mvM stresses in the endocrown did not exceed the tensile strength of ceramic. In the molar with an FRC posts (Model C), equivalent stress values in dentin increased by 42% versus Model B. In ceramic crown of Model C the stresses were 31% higher and in the resin luting cement were 61% higher than in the tooth with endocrown. Tensile contact stresses in the adhesive cement-dentin interface around FRC posts achieved 4 times higher values than under endocrown and shear stresses increased twice. The contact stress values around the appliances were several time smaller than cement-dentin bond strength. Teeth restored by endocrowns are potentially more resistant to failure than those with FRC posts. Under physiological loads, ceramic endocrowns ideally cemented in molars should not be demaged or debonded. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Upadhyaya, Viram; Bhargava, Akshay; Parkash, Hari; Chittaranjan, B; Kumar, Vivek
2016-01-01
Different postdesigns and materials are available; however, no consensus exists regarding superiority for stress distribution. The aim of this study was to evaluate the effect of design and material of post with or without ferrule on stress distribution using finite element analysis. A total of 12 three-dimensional (3D) axisymmetric models of postretained central incisors were made: Six with ferrule design and six without it. Three of these six models had tapered posts, and three had parallel posts. The materials tested were titanium post with a composite resin core, nickel chromium cast post and core, and fiber reinforced composite (FRC) post with a composite resin core. The stress analysis was done using ANSYS software. The load of 100 N at an angle of 45 was applied 2 mm cervical to incisal edge on the palatal surface and results were analyzed using 3D von Mises criteria. The highest amount of stress was in the cervical region. Overall, the stress in the tapered postsystem was more than the parallel one. FRC post and composite resin core recorded minimal stresses within the post but the stresses transmitted to cervical dentin were more as compared to other systems. Minimal stresses in cervical dentine were observed where the remaining coronal dentin was strengthen by ferrule. A rigid material with high modulus of elasticity for post and core system creates most uniform stress distribution pattern. Ferrule provides uniform distribution of stresses and decreases the cervical stresses.
Parčina, Ivana; Amižić; Miletić, Ivana; Ionescu, Andrei C; Brambilla, Eugenio; Gabrić, Dragana; Baraba, Anja
2016-12-01
The aim of this in vitro study was to investigate the effect of laser activated irrigation (LAI) using two erbium lasers on bond strength of individually formed fiber-reinforced composite (FRC) posts to root canal dentin. Twenty-seven single-rooted human teeth were endodontically treated and after post space preparation divided into three groups (n=9 per group), according to the pre-treatment of post space preparation: 1) Conventional syringe irrigation (CSI) and saline; 2) Er.YAG photon-induced photoacoustic streaming (PIPS) technique and saline; 3) Er,Cr:YSGG activated irrigation with RFT2 tip. Two specimens from each group were used for SEM analysis. The remaining specimens (n=7 per group) received individually formed FRC post, everStick POST, luted with self-adhesive cement, G-CEM LinkAce. After cementation, the roots were perpendicularly sectioned into 1 mm thin sections and a push-out test was carried out (0.5 mm/min). The data were calculated as megapascals and were log transformed and statistically analysed using one-way ANOVA at the level of significance set at 5%. In the control group, the smear layer was still present. In the Er:YAG group, the smear layer was removed. In the Er,Cr:YSGG group, the smear layer was partially removed. The Er,Cr:YSGG group achieved the highest bond strength values, followed by the control group and then the Er:YAG group, but no statistically significant difference was found in bond strength values in the tested group of post space pretreatment (p=0.564). LAI using two erbium lasers, with PIPS or RFT2 tip, did not affect the bond strength of individually formed FRC posts to root canal dentin.
Malmstrom, H; Dellanzo-Savu, A; Xiao, J; Feng, C; Jabeen, A; Romero, M; Huang, J; Ren, Y; Yunker, M A
2015-12-01
To evaluate the success, clinical performance and patient satisfaction of directly placed fibre-reinforced composite (FRC) fixed partial dentures (FPDs) in 2 years. One hundred sixty-seven FRC FPDs (120 subjects) were directly fabricated to restore a single missing tooth by six Advanced Education in General Dentistry (AEGD) residents. The FRC FPDs recipients were randomised into two groups according to the fibre materials (pre-impregnated glass or polyethylene). Clinical performance was evaluated at baseline (2 weeks), 6, 12 and 24 months by two calibrated evaluators for prosthesis adaptation, colour match, marginal discoloration, surface roughness, caries and post-operative sensitivity using modified United State Public Health Service (USPHS) criteria. Prosthesis appearance, colour, chewing ability and overall satisfaction were evaluated by patients using a visual analogue scale (VAS). Kaplan-Meier estimation was used to estimate the prosthesis success. Ninety-four patients with 137 FRC FPDs returned (21·67% attrition rate for study subjects, 17·94% for FRC FPDs). Seventeen FRC FPDs failed, due to one-end (n = 4) or two-ends (n = 4) debonding or pontic fracture (n = 9). The cumulative 2-year success rate was 84·32% and survival rate was 92·7%; there were no statistically significant differences between the groups according to different missing tooth location, retention type or fibre materials (P > 0·05). Patient satisfaction regarding prosthesis appearance, col-our, chewing ability and overall satisfaction was rated high on the VAS (mean >80 mm) for all criteria at all time points. The FRC FPDs (restoring single tooth) fabricated by AEGD residents achieved acceptable success and survival rates in a 2-year follow-up. © 2015 John Wiley & Sons Ltd.
Keulemans, Filip; De Jager, Niek; Kleverlaan, Cornelis J; Feilzer, Albert J
2008-10-01
The aim of this study was to evaluate in vitro the influence of retainer design on the strength of two-unit cantilever resin-bonded glass fiber-reinforced composite (FRC) fixed dental prostheses (FDP). Four retainer designs were tested: a proximal box, a step-box, a dual wing, and a step-box-wing. Of each design on 8 human mandibular molars, FRC-FDPs of a premolar size were produced. The FRC framework was made of resin impregnated unidirectional glass fibers (Estenia C&B EG Fiber, Kuraray) and veneered with hybrid resin composite (Estenia C&B, Kuraray). Panavia F 2.0 (Kuraray) was used as resin luting cement. FRC-FDPs were loaded to failure in a universal testing machine. One-way ANOVA and Tukey's post-hoc test were used to evaluate the data. The four designs were analyzed with finite element analysis (FEA) to reveal the stress distribution within the tooth/restoration complex. Significantly lower fracture strengths were observed with inlay-retained FDPs (proximal box: 300 +/- 65 N; step-box: 309 +/- 37 N) compared to wing-retained FDPs (p < 0.05) (step-box-wing: 662 +/- 99 N; dual wing: 697 +/- 67 N). Proximal-box-, step-box-, and step-box-wing-retained FDPs mainly failed with catastrophic cusp fracture (proximal box 100%, step-box 100%, and step-box-wing 75%), while dual-wing-retained FDPs mainly failed at the adhesive interface and/or due to pontic failure (75%). FEA showed more favorable stress distributions within the tooth/restoration complex for dual wing retainers. A dual-wing retainer is the optimal design for replacement of a single premolar by means of a two-unit cantilever FRC-FDPs.
Sobouti, Farhad; Rakhshan, Vahid; Saravi, Mahdi Gholamrezaei; Zamanian, Ali; Shariati, Mahsa
2016-03-01
Traditional retainers (both metal and fiber-reinforced composite [FRC]) have limitations, and a retainer made from more flexible ligature wires might be advantageous. We aimed to compare an experimental design with two traditional retainers. In this prospective preliminary clinical trial, 150 post-treatment patients were enrolled and randomly divided into three groups of 50 patients each to receive mandibular canine-to-canine retainers made of FRC, flexible spiral wire (FSW), and twisted wire (TW). The patients were monitored monthly. The time at which the first signs of breakage/debonding were detected was recorded. The success rates of the retainers were compared using chi-squared, Kaplan-Meier, and Cox proportional-hazard regression analyses (α = 0.05). In total, 42 patients in the FRC group, 41 in the FSW group, and 45 in the TW group completed the study. The 2-year failure rates were 35.7% in the FRC group, 26.8% in the FSW group, and 17.8% in the TW group. These rates differed insignificantly (chi-squared p = 0.167). According to the Kaplan-Meier analysis, failure occurred at 19.95 months in the FRC group, 21.37 months in the FSW group, and 22.36 months in the TW group. The differences between the survival rates in the three groups were not significant (Cox regression p = 0.146). Although the failure rate of the experimental retainer was two times lower than that of the FRC retainer, the difference was not statistically significant. The experimental TW retainer was successful, and larger studies are warranted to verify these results.
Sobouti, Farhad; Rakhshan, Vahid; Saravi, Mahdi Gholamrezaei; Zamanian, Ali
2016-01-01
Objective Traditional retainers (both metal and fiber-reinforced composite [FRC]) have limitations, and a retainer made from more flexible ligature wires might be advantageous. We aimed to compare an experimental design with two traditional retainers. Methods In this prospective preliminary clinical trial, 150 post-treatment patients were enrolled and randomly divided into three groups of 50 patients each to receive mandibular canine-to-canine retainers made of FRC, flexible spiral wire (FSW), and twisted wire (TW). The patients were monitored monthly. The time at which the first signs of breakage/debonding were detected was recorded. The success rates of the retainers were compared using chi-squared, Kaplan-Meier, and Cox proportional-hazard regression analyses (α = 0.05). Results In total, 42 patients in the FRC group, 41 in the FSW group, and 45 in the TW group completed the study. The 2-year failure rates were 35.7% in the FRC group, 26.8% in the FSW group, and 17.8% in the TW group. These rates differed insignificantly (chi-squared p = 0.167). According to the Kaplan-Meier analysis, failure occurred at 19.95 months in the FRC group, 21.37 months in the FSW group, and 22.36 months in the TW group. The differences between the survival rates in the three groups were not significant (Cox regression p = 0.146). Conclusions Although the failure rate of the experimental retainer was two times lower than that of the FRC retainer, the difference was not statistically significant. The experimental TW retainer was successful, and larger studies are warranted to verify these results. PMID:27019825
Factors affecting the cement-post interface.
Zicari, F; De Munck, J; Scotti, R; Naert, I; Van Meerbeek, B
2012-03-01
To evaluate the effect of different factors on the push-out bond strength of glass fiber posts luted in simulated (standard) root canals using different composite cements. Three types of glass-fiber root-canal posts with a different matrix, namely an epoxy resin (RelyX post, 3M ESPE), a proprietary composite resin (FRC-Plus post, Ivoclar-Vivadent), and a methacrylate resin (GC post, GC), and three types of composite cements, namely an etch-and-rinse Bis-GMA-based (Variolink II, Ivoclar-Vivadent), a self-etch 10-MDP-based (Clearfil Esthetic Cement, Kuraray) and a self-adhesive (RelyX Unicem, 3M ESPE) cement, were tested. Posts were either left untreated (control), were treated with silane, or coated with silicated alumina particles (Cojet system, 3M ESPE). Posts were inserted up to 9-mm depth into composite CAD-CAM blocks (Paradigm, 3M ESPE) in order to solely test the strength of the cement-post interface, while excluding interference of the cement-dentin interface. After 1-week storage at 37 °C, three sections (coronal, middle, apical) of 2-mm thickness were subjected to a push-out bond-strength test. All three variables, namely the type of post, the composite cement and the post-surface pre-treatment, were found to significantly affect the push-out bond strength (p<0.001). Regarding the type of post, a significantly lower push-out bond strength was recorded for the FRC-Plus post (Ivoclar-Vivadent); regarding the composite cement, a significantly higher push-out bond strength was recorded for the self-adhesive cement Unicem (3M ESPE); and regarding the post-surface treatment, a significantly higher push-out bond strength was recorded when the post-surface was beforehand subjected to a Cojet (3M ESPE) combined sandblasting/silicatization surface pre-treatment. Many interactions between these three variables were found to be significant as well (p<0.001). Finally, the push-out bond strength was found to significantly reduce with depth from coronal to apical. Laboratory testing revealed that different variables like the type of post, the composite cement and the post-surface pre-treatment may influence the cement-post interface, making clear guidelines for routine clinical practice hard to define. Further long-term durability testing may help to clarify, and should therefore be encouraged. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Residual monomers and degree of conversion of partially bioresorbable fiber-reinforced composite.
Väkiparta, Marju; Puska, Mervi; Vallittu, Pekka K
2006-01-01
The aim of this study was to evaluate the total quantity of residual monomer (bis-phenyl glycidyl dimethacrylate, i.e. Bis-GMA, and triethylene glycol dimethacrylate, i.e. TEGDMA), residual monomer release into water and the degree of monomer conversion (DC%) of glass fiber-reinforced composites (FRC) with a partially bioresorbable polymer matrix. Another aim was to find out whether the curing mode affects the quantity of residual monomer and degree of conversion. Glass fibers were preimpregnated with a bioresorbable poly(hydroxyproline) amide and non-resorbable Bis-GMA-TEGDMA resin system. Specimens were immersed in water for 1, 3 or 7 days (37 degrees C) to determine the quantity of leached residual monomers, or in the solvent tetrahydrofuran for 3 days to determine the total quantity of residual monomers by high performance liquid chromatography. DC% was measured by Fourier transform infrared spectroscopy. The quantity of residual monomer of the specimens decreased when the specimens contained glass fibers, and/or poly(hydroxyproline) amide, and/or when it was post-cured. The majority of the residual monomers were leached out during the first 24 h of immersion in water. The DC% of the specimens increased when post-cured. Also glass fibers in the composite increased the DC% in contrast to Bis-GMA-TEGDMA resin only. In conclusion, use of poly(hydroxyproline) amide as a sizing of the glass fibers in FRC does not increase the quantity of residual monomers. These results suggest that this new kind of partially bioresorbable FRC has potential for biomedical applications.
Surface modification of quartz fibres for dental composites through a sol-gel process.
Wang, Yazi; Wang, Renlin; Habib, Eric; Wang, Ruili; Zhang, Qinghong; Sun, Bin; Zhu, Meifang
2017-05-01
In this study, quartz fibres (QFs) surface modification using a sol-gel method was proposed and dental posts reinforced with modified QFs were produced. A silica sol (SS) was prepared using tetraethoxysilane (TEOS) and 3-methacryloxypropyltrimethoxysilane (γ-MPS) as precursors. The amount of γ-MPS in the sol-gel system was varied from 0 to 24wt.% with a constant molar ratio of TEOS, ethanol, deionized water, and HCl. Thermogravimetric analysis (TGA), Fourier transform infrared spectroscopy (FT-IR), and contact angle (CA) measurements were used to characterize the modified QFs, which confirmed that SS had successfully coated the surface of QFs. SEM images showed good interfacial bonding between the modified QFs and the resin matrix. The results of three-point bending tests of the fibre reinforced composite (FRC) posts showed that the QFs modified by SS with 12wt.% γ-MPS presented the best mechanical properties, demonstrating improvements of 108.3% and 89.6% for the flexural strength and flexural modulus, respectively, compared with untreated QFs. Furthermore, the sorption and solubility of the prepared dental posts were also studied by immersing the posts in artificial saliva (AS) for 4weeks, and yielded favourable results. This sol-gel surface modification method promises to resolve interfacial bonding issues of fibres with the resin matrix, and produce FRC posts with excellent properties. Copyright © 2017. Published by Elsevier B.V.
Fracture behavior of single-structure fiber-reinforced composite restorations
Nagata, Kohji; Garoushi, Sufyan K.; Vallittu, Pekka K.; Wakabayashi, Noriyuki; Takahashi, Hidekazu; Lassila, Lippo V. J.
2016-01-01
Abstract Objective: The applications of single-structure fiber-reinforced composite (FRC) in restorative dentistry have not been well reported. This study aimed to clarify the static mechanical properties of anterior crown restorations prepared using two types of single-structure FRC. Materials and methods : An experimental crown restoration was designed for an upper anterior incisor. The restorations were made from IPS Empress CAD for CEREC (Emp), IPS e.max® CAD (eMx), experimental single-structure all-FRC (a-FRC), Filtek™ Supreme XTE (XTE), and commercially available single-structure short-FRC (everX Posterior™) (n = 8 for each material) (s-FRC). The a-FRC restorations were prepared from an experimental FRC blank using a computer-aided design and manufacturing (CAD/CAM) device. A fracture test was performed to assess the fracture load, toughness, and failure mode. The fracture loads were vertically applied on the restorations. The surface micromorphology of the FRC restorations was observed by scanning electron microscopy (SEM). The data were analyzed by analysis of variance (p = .05) followed by Tukey's test. Results : s-FRC showed the highest mean fracture load (1145.0 ± 89.6 N) and toughness (26.2 ± 5.8 Ncm) among all the groups tested. With regard to the micromorphology of the prosthetic surface, local crushing of the fiberglass was observed in s-FRC, whereas chopped fiberglass was observed in a-FRC. Conclusions : The restorations made of short-FRC showed a higher load-bearing capacity than those made of the experimental all-FRC blanks for CAD/CAM. The brittle-like fractures were exhibited in the recent dental esthetic materials, while local crushing fractures were shown for single-structure FRC restorations. PMID:28642921
Immediate Repair Bond Strength of Fiber-reinforced Composite after Saliva or Water Contamination.
Bijelic-Donova, Jasmina; Flett, Andrew; Lassila, Lippo V J; Vallittu, Pekka K
2018-05-31
This in vitro study aimed to evaluate the shear bond strength (SBS) of particulate filler composite (PFC) to saliva- or water-contaminated fiber-reinforced composite (FRC). One type of FRC substrate with semi-interpenetrating polymer matrix (semi-IPN) (everStick C&B) was used in this investigation. A microhybrid PFC (Filtek Z250) substrate served as control. Freshly cured PFC and FRC substrates were first subjected to different contamination and surface cleaning treatments, then the microhybrid PFC restorative material (Filtek Z250) was built up on the substrates in 2-mm increments and light cured. Uncontaminated and saliva- or water-contaminated substrate surfaces were either left untreated or were cleaned via phosphoric acid etching or water spray accompanied with or without adhesive composite application prior applying the adherent PFC material. SBS was evaluated after thermocycling the specimens (6000 cycles, 5°C and 55°C). Three-way ANOVA showed that both the surface contamination and the surface treatment signficantly affected the bond strength (p < 0.05). Saliva contamination reduced the SBS more than did the water contamination. SBS loss after saliva contamination was 73.7% and 31.3% for PFC and FRC, respectively. After water contamination, SBS loss was 17.2% and 13.3% for PFC and FRC, respectively. The type of surface treatment was significant for PFC (p < 0.05), but not for FRC (p = 0.572). Upon contamination of freshly cured PFC or semi-IPN FRC, surfaces should be re-prepared via phosphoric acid etching, water cleaning, drying, and application of adhesive composite in order to recover optimal bond strength.
Reza, Fazal; Ibrahim, Nur Sukainah
2015-01-01
Fiber post is cemented to a root canal to restore coronal tooth structure. This research aims to evaluate the effect of ultraviolet (UV) irradiation on bond strength of fiber post with resin cement. A total of 40 of the two types of fiber posts, namely, FRC Prostec (FRC) and Fiber KOR (KOR), were used for the experiment. UV irradiation was applied on top of the fiber post surface for 0, 15, 20, and 30 min. The irradiated surface of the fiber posts (n = 5) were immediately bonded with resin cement (Rely X U200) after UV irradiation. Shear bond strength (SBS) MPa was measured, and the dislodged area of post surfaces was examined with scanning electron microscopes. Changes in surface roughness (Ra) of the FRC group after UV irradiation were observed (n = 3) using atomic force microscopy. Data of SBS were statistically analyzed using one-way analysis of variance, followed by multiple comparisons (P < 0.05). SBS was significantly higher for 20 min of UV irradiation of the FRC group while significantly higher SBS was observed with 15 min of UV irradiation of the KOR group. Resin cement was more evident (cohesive failure) on the dislodged post surface of the UV treated groups compared with the control. The surface roughness of the FRC post was Ra = 175.1 nm and Ra = 929.2 nm for the control and the 20 min group, respectively. Higher surface roughness of the UV irradiated group indicated formation of mechanical retention on the fiber post surface. Evidence of cohesive failure was observed which indicated higher SBS of fiber post with the UV irradiated group.
Reza, Fazal; Ibrahim, Nur Sukainah
2015-01-01
Objective: Fiber post is cemented to a root canal to restore coronal tooth structure. This research aims to evaluate the effect of ultraviolet (UV) irradiation on bond strength of fiber post with resin cement. Materials and Methods: A total of 40 of the two types of fiber posts, namely, FRC Prostec (FRC) and Fiber KOR (KOR), were used for the experiment. UV irradiation was applied on top of the fiber post surface for 0, 15, 20, and 30 min. The irradiated surface of the fiber posts (n = 5) were immediately bonded with resin cement (Rely X U200) after UV irradiation. Shear bond strength (SBS) MPa was measured, and the dislodged area of post surfaces was examined with scanning electron microscopes. Changes in surface roughness (Ra) of the FRC group after UV irradiation were observed (n = 3) using atomic force microscopy. Data of SBS were statistically analyzed using one-way analysis of variance, followed by multiple comparisons (P < 0.05). Results: SBS was significantly higher for 20 min of UV irradiation of the FRC group while significantly higher SBS was observed with 15 min of UV irradiation of the KOR group. Resin cement was more evident (cohesive failure) on the dislodged post surface of the UV treated groups compared with the control. The surface roughness of the FRC post was Ra = 175.1 nm and Ra = 929.2 nm for the control and the 20 min group, respectively. Conclusions: Higher surface roughness of the UV irradiated group indicated formation of mechanical retention on the fiber post surface. Evidence of cohesive failure was observed which indicated higher SBS of fiber post with the UV irradiated group. PMID:25713488
Kosor, Begüm Yerci; Artunç, Celal; Şahan, Heval
2015-07-01
A key factor of an implant-retained facial prosthesis is the success of the bonding between the substructure and the silicone elastomer. Little has been reported on the bonding of fiber reinforced composite (FRC) to silicone elastomers. Experimental FRC could be a solution for facial prostheses supported by light-activated aliphatic urethane acrylate, orthodontic acrylic resin, or commercially available FRCs. The purpose of this study was to evaluate the bonding of the experimental FRC, orthodontic acrylic resin, and light-activated aliphatic urethane acrylate to a commercially available high-temperature vulcanizing silicone elastomer. Shear and 180-degree peel bond strengths of 3 different substructures (experimental FRC, orthodontic acrylic resin, light-activated aliphatic urethane acrylate) (n=15) to a high-temperature vulcanizing maxillofacial silicone elastomer (M511) with a primer (G611) were assessed after 200 hours of accelerated artificial light-aging. The specimens were tested in a universal testing machine at a cross-head speed of 10 mm/min. Data were collected and statistically analyzed by 1-way ANOVA, followed by the Bonferroni correction and the Dunnett post hoc test (α=.05). Modes of failure were visually determined and categorized as adhesive, cohesive, or mixed and were statistically analyzed with the chi-squared goodness-of-fit test (α=.05). As the mean shear bond strength values were evaluated statistically, no difference was found among the experimental FRC, aliphatic urethane acrylate, and orthodontic acrylic resin subgroups (P>.05). The mean peel bond strengths of experimental fiber reinforced composite and aliphatic urethane acrylate were not found to be statistically different (P>.05). The mean value of the orthodontic acrylic resin subgroup peel bond strength was found to be statistically lower (P<.05). Shear test failure types were found to be statistically different (P<.05), whereas 180-degree peel test failure types were not found to be statistically significant (P>.05). Shear forces predominantly exhibited cohesive failure (64.4%), whereas peel forces predominantly exhibited adhesive failure (93.3%). The mean shear bond strengths of the experimental FRC and aliphatic urethane acrylate groups were not found to be statistically different (P>.05). The mean value of the 180-degree peel strength of the orthodontic acrylic resin group was found to be lower (P<.05). Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Polacek, Petr; Pavelka, Vladimir; Ozcan, Mutlu
2013-12-01
To evaluate the effect of different polymerization sequences employed during application of bis-GMAbased particulate filler composites (PFC) or a flowable resin (FR) on fiber-reinforced composite (FRC). Unidirectional, pre-impregnated S2-glass fibers (Dentapreg) and multidirectional preimpregnated E-glass fibers (Dentapreg) (length: 40 mm; thickness: 0.5 mm) were obtained (N = 144, n = 12 per group) and embedded in translucent silicone material with the adhesion surface exposed. The resulting specimens were randomly divided into 12 groups for the following application sequences: a) FRC+PFC (photopolymerized in one step), b) FRC+FR (photopolymerized in one step), c) FRC+PFC (photopolymerized individually), d) FRC+FR (photopolymerized individually), e) FRC (photopolymerized)+intermediate adhesive resin and PFC (photopolymerized in one step), f) FRC (photopolymerized)+intermediate adhesive resin and FR (photopolymerized in one step). The sequences of unidirectional (groups a to f) were repeated for multidirectional (groups g to l) FRCs. PFCs were debonded from the FRC surfaces using the shear bond test in a universal testing machine (1 mm/min). On additional specimens from each FRC type, thermogravimetric analysis (TGA) was performed to characterize the fiber weight content (Wf) (N = 6, n = 3 per group). After debonding, all specimens were analyzed using SEM to categorize the failure modes. The data were statistically analyzed using 3-way ANOVA and Tukey's tests (α = 0.05). Significant effects of the FRC type (S2 or E-glass) (p < 0.01), resin type (PFC or FR) (p < 0.01) and polymerization protocol (p < 0.05) were observed on the bond strength (MPa). Interaction terms were also significant (p < 0.05). The multidirectional FRC groups (g to l) showed significantly lower bond strengths (2.3 ± 0.2 to 7.3 ± 0.3 MPa) than did the unidirectional FRC groups (a to f) (10.7 ± 0.6 to 24.4 ± 0.8 MPa). Among the unidirectional FRC groups, the highest values were obtained with protocol f (24.4 ± 0.8), followed by protocol e (18.6 ± 0.4). PFC adhesion to unidirectional FRC was lower when FRC and PFC were polymerized in one step (protocol a: 11.3 ± 0.5) than individual polymerization (protocol c: 14.1 ± 0.5). The opposite situation was true for FR (protocol b: 17.5 ± 0.4; protocol d: 10.7 ± 0.6). Groups a to f presented exclusively mixed failures (a combination of partial cohesive failure in the PFC and adhesive failure between the FRC and PFC) and groups g to l demonstrated only adhesive failure (intact FRC no cohesive failure of PFC). TGA revealed 55 ± 3 wt% fiber content for multidirectional and 60 ± 3 wt% for unidirectional FRCs tested. Multidirectional pre-impregnated E-glass fibers cannot be recommended in combination with the PFC and FR materials tested in this study. Application of an intermediate adhesive resin layer increases the adhesion of both PFC and FR to unidirectional FRC. FRC and FR can be polymerized in one step, but FRC and PFC combinations should be polymerized individually.
Vallittu, Pekka K.
2018-01-01
Abstract Fibr-reinforced composites (FRC) have been used successfully for decades in many fields of science and engineering applications. Benefits of FRCs relate to physical properties of FRCs and versatile production methods, which can be utilized. Conventional hand lamination of prefabricated FRC prepregs is utilized still most commonly in fabrication of dental FRC devices but CAD-CAM systems are to be come for use in certain production steps of dental constructions and medical FRC implants. Although metals, ceramics and particulate filler resin composites have successfully been used as dental and medical biomaterials for decades, devices made out of these materials do not meet all clinical requirements. Only little attention has been paid to FRCs as dental materials and majority of the research in dental field has been focusing on particulate filler resin composites and in medical biomaterial research to biodegradable polymers. This is paradoxical because FRCs can potentially resolve many of the problems related to traditional isotropic dental and medical materials. This overview reviews the rationale and status of using biostable glass FRC in applications from restorative and prosthetic dentistry to cranial surgery. The overview highlights also the critical material based factors and clinical requirement for the succesfull use of FRCs in dental reconstructions. PMID:29707613
Vallittu, Pekka K
2018-01-01
Fibr-reinforced composites (FRC) have been used successfully for decades in many fields of science and engineering applications. Benefits of FRCs relate to physical properties of FRCs and versatile production methods, which can be utilized. Conventional hand lamination of prefabricated FRC prepregs is utilized still most commonly in fabrication of dental FRC devices but CAD-CAM systems are to be come for use in certain production steps of dental constructions and medical FRC implants. Although metals, ceramics and particulate filler resin composites have successfully been used as dental and medical biomaterials for decades, devices made out of these materials do not meet all clinical requirements. Only little attention has been paid to FRCs as dental materials and majority of the research in dental field has been focusing on particulate filler resin composites and in medical biomaterial research to biodegradable polymers. This is paradoxical because FRCs can potentially resolve many of the problems related to traditional isotropic dental and medical materials. This overview reviews the rationale and status of using biostable glass FRC in applications from restorative and prosthetic dentistry to cranial surgery. The overview highlights also the critical material based factors and clinical requirement for the succesfull use of FRCs in dental reconstructions.
Multi-Scale CNT-Based Reinforcing Polymer Matrix Composites for Lightweight Structures
NASA Technical Reports Server (NTRS)
Eberly, Daniel; Ou, Runqing; Karcz, Adam; Skandan, Ganesh; Mather, Patrick; Rodriguez, Erika
2013-01-01
Reinforcing critical areas in carbon polymer matrix composites (PMCs), also known as fiber reinforced composites (FRCs), is advantageous for structural durability. Since carbon nanotubes (CNTs) have extremely high tensile strength, they can be used as a functional additive to enhance the mechanical properties of FRCs. However, CNTs are not readily dispersible in the polymer matrix, which leads to lower than theoretically predicted improvement in mechanical, thermal, and electrical properties of CNT composites. The inability to align CNTs in a polymer matrix is also a known issue. The feasibility of incorporating aligned CNTs into an FRC was demonstrated using a novel, yet commercially viable nanofiber approach, termed NRMs (nanofiber-reinforcing mats). The NRM concept of reinforcement allows for a convenient and safe means of incorporating CNTs into FRC structural components specifically where they are needed during the fabrication process. NRMs, fabricated through a novel and scalable process, were incorporated into FRC test panels using layup and vacuum bagging techniques, where alternating layers of the NRM and carbon prepreg were used to form the reinforced FRC structure. Control FRC test panel coupons were also fabricated in the same manner, but comprised of only carbon prepreg. The FRC coupons were machined to size and tested for flexural, tensile, and compression properties. This effort demonstrated that FRC structures can be fabricated using the NRM concept, with an increased average load at break during flexural testing versus that of the control. The NASA applications for the developed technologies are for lightweight structures for in-space and launch vehicles. In addition, the developed technologies would find use in NASA aerospace applications such as rockets, aircraft, aircraft/spacecraft propulsion systems, and supporting facilities. The reinforcing aspect of the technology will allow for more efficient joining of fiber composite parts, thus offering additional weight savings. More robust structures capable of withstanding micrometeoroid and space debris impacts will be possible with the enhanced mechanical properties imparted by the aligned CNTs incorporated into the fiber composite structure, as well as the potential for improved electrical and thermal properties. The materials fabrication approach developed in the present effort is a platform for customer applications where additional reinforcement is required or would be beneficial, especially in FRC structures and component parts. Depending upon the specific customer application, the NRM could be tailored to the specific matrix resin and desired property enhancement.
Abdulmajeed, Aous A; Närhi, Timo O; Vallittu, Pekka K; Lassila, Lippo V
2011-04-01
This study was designed to evaluate the effect of an increase of fiber-density on some mechanical properties of higher volume fiber-reinforced composite (FRC). Five groups of FRC with increased fiber-density were fabricated and two additional groups were prepared by adding silanated barium-silicate glass fillers (0.7 μm) to the FRC. The unidirectional E-glass fiber rovings were impregnated with light-polymerizable bisGMA-TEGDMA (50-50%) resin. The fibers were pulled through a cylindrical mold with an opening diameter of 4.2mm, light cured for 40s and post-cured at elevated temperature. The cylindrical specimens (n=12) were conditioned at room temperature for 2 days before testing with the three-point bending test (Lloyd Instruments Ltd.) adapted to ISO 10477. Fiber-density was analyzed by combustion and gravimetric analyzes. ANOVA analysis revealed that by increasing the vol.% fraction of E-glass fibers from 51.7% to 61.7% there was a change of 27% (p<0.05) in the modulus of elasticity, 34% (p<0.05) in the toughness, and 15% (p<0.05) in the load bearing capacity, while there was only 8% (p<0.05) increase in the flexural strength although it was statistically insignificant. The addition of particulate fillers did not improve the mechanical properties. This study showed that the properties of FRC could be improved by increasing fibervolume fraction. Modulus of elasticity, toughness, and load bearing capacity seem to follow the law of ratio of quantity of fibers and volume of the polymer matrix more precisely than flexural strength when high fiber-density is used. Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Ballo, Ahmed M; Akca, Eralp; Ozen, Tuncer; Moritz, Niko; Lassila, Lippo; Vallittu, Pekka; Närhi, Timo
2014-08-01
This study aimed to evaluate the influence of implant design and bioactive glass (BAG) coating on the response of bone to fiber-reinforced composite (FRC) implants. Three different FRC implant types were manufactured for the study: non-threaded implants with a BAG coating; threaded implants with a BAG coating; and threaded implants with a grit-blasted surface. Thirty-six implants (six implants for each group per time point) were installed in the tibiae of six pigs. After an implantation period of 4 and 12 wk, the implants were retrieved and prepared for micro-computed tomography (micro-CT), push-out testing, and scanning electron microscopy analysis. Micro-CT demonstrated that the screw-threads and implant structure remained undamaged during the installation. The threaded FRC/BAG implants had the highest bone volume after 12 wk of implantation. The push-out strengths of the threaded FRC/BAG implants after 4 and 12 wk (463°N and 676°N, respectively) were significantly higher than those of the threaded FRC implants (416°N and 549°N, respectively) and the nonthreaded FRC/BAG implants (219°N and 430°N, respectively). Statistically significant correlation was found between bone volume and push-out strength values. This study showed that osseointegrated FRC implants can withstand the static loading up to failure without fracture, and that the addition of BAG significantly improves the push-out strength of FRC implants. © 2014 Eur J Oral Sci.
Adhesion of maxillofacial silicone elastomer to a fiber-reinforced composite resin framework.
Kantola, Rosita; Lassila, Lippo; Vallittu, Pekka
2011-01-01
Recently, fiber-reinforced composite resin (FRC) has been introduced as a framework material for maxillofacial silicone prostheses. The purpose of this research was to study the tensile bond strength between a room temperature-polymerized maxillofacial silicone elastomer and a unidirectional FRC. Three different bonding agents were compared. Specimens were loaded in tension mode according to ISO 22401 in a universal testing device with a crosshead speed of 10 mm/min until bonding failure occurred. The influence of the surface characteristics (ground vs intact) was also studied. The highest tensile bond strength was seen with Gold Platinum Primer A-330-G, followed by Sofreliner primer. One-way analysis of variance revealed that the surface treatment of the FRC and the adhesive used had a significant effect on tensile bond strength between silicone and FRC (P < .05). Grinding enhanced adhesion, especially with Gold Platinum Primer A-330-G and Sofreliner primer. The fracture type also changed to more cohesive in nature. The FRC substructure can successfully be bonded to maxillofacial silicone elastomer by using primer containing methyl ethyl ketone and dichloromethane solvent. Bonding can be improved by roughening the FRC substrate via grinding.
NASA Astrophysics Data System (ADS)
Bongers, Bernd; Haider, Otmar; Tauber, Wolfgang
1990-09-01
For the thermal insulation of cryogenic tanks in satellite applications Fiber Reinforced Composite (FRC) materials are preferable because of their low thermal conductivity and high tensile strength compared to metallic materials. At the Infrared Space Observatory (ISO) satellite the main Liquid Helium (LHe) tank is suspended by one spatial framework and eight pretensioned chain strands at each side. Frameworks and chain strands are acting as a thermal barrier and therefore made of FRC. To meet the various and, in parts contractive requirements, sophisticated design approaches are chosen for the structural parts.
2016-11-01
layered glass/PC systems,Functionally Graded Materials (FGMs), polycrystalline AlON, and fiber-reinforced composite (FRC) materials. For the first time we...multi-layered glass/PC systems,Functionally Graded Materials (FGMs), polycrystalline AlON, and fiber-reinforced composite (FRC) materials. For the... Composite Lamina with Peridynamics, International Journal for Multiscale Computational Engineering, (12 2011): 0. doi: Florin Bobaru, Youn Doh Ha
Framework design and pontics of fiber-reinforced composite fixed dental prostheses - An overview.
Perea-Lowery, Leila; Vallittu, Pekka K
2018-05-11
Fiber-reinforced composite (FRC) fixed dental prostheses (FDPs) have shown good performance in clinical applications due to their good mechanical properties and minimally invasive approach. However, typical failure patterns of FRC FDPs are often localized at the pontic site. That reflects the structural considerations at the framework and pontic location that need to be examined when creating these kinds of prostheses. Peer-reviewed articles and other scientific literature were reviewed for providing up-to-date information on how pontics of FRC FDPs can be made. A thorough literature search was done using PubMed and Google Scholar. Two individuals did an assessment of the articles in order to include those related to pontics and framework design of FRC FDPs. The search terms used were "fiber-reinforced dental prosthesis" and "Pontics of fiber-reinforced dental prosthesis". These findings indicate that a cross-sectional fiber design, substructure and thicker pontics made of a variety of materials might reduce failures at the pontic site. The thickness of pontics of FRC FDPs interrelated with the vertical positioning of the FRC framework influences the load-bearing capacities of prostheses of these kinds. The understanding of the factors involved in the fabrication of pontics of FRC FDPs may overcome the drawbacks identified in these prostheses, thus extending their longevity. Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Pastila, Pirjo; Lassila, Lippo V J; Jokinen, Mikko; Vuorinen, Jyrki; Vallittu, Pekka K; Mäntylä, Tapio
2007-07-01
This study was aimed to determine if short-term water storage would change elastic properties of dental composite materials. Particulate filler composite resin and continuous unidirectional E-glass FRC materials were photopolymerized and additionally post-polymerized by heat for testing elastic properties with the Resonance Ultrasound Spectroscopy method as a function of time in water storage. The test specimens were stored in 37 degrees C water for up to 30 days. About 1% weight increase due to water sorption was observed in both materials with both polymerization methods. Water sorption did not change the resonance frequencies towards lower values, indicating no significant decrease in elastic properties in these materials. Because of high damping of the polymer composite materials leading to wide resonance peaks and low number of the recorded peaks, accurate determination of the elastic properties was not possible. Results suggest that the most likely explanation for the previously observed decrease in bending stiffness of FRC materials is the decreased yield limit of the hydrated polymer matrix. It is important to recognize that water sorption has the effect on mechanical properties of dental composite materials by changing the yield limit of the matrix rather than by changing the elastic properties of the material.
Chieruzzi, Manila; Rallini, Marco; Pagano, Stefano; Eramo, Stefano; D'Errico, Potito; Torre, Luigi; Kenny, José M
2014-02-01
The aim of this study was to investigate the mechanical behavior of a dental system built up with fiber-reinforced composite (FRC) endodontic posts with different types of fibers and two cements (the first one used with a primer, the second one without it). Six FRC posts were used. Each system was characterized in terms of structural efficiency under external applied loads similar to masticatory forces. An oblique force was applied and stiffness and maximum load data were obtained. The same test was used for the dentine. The systems were analyzed by scanning electron microscope (SEM) to investigate the surface of the post and inner surface of root canal after failure. The mechanical tests showed that load values in dental systems depend on the post material and used cement. The highest load (281 ± 59 N) was observed for the conical glass fiber posts in the cement without primer. There was a 50 and 85% increase in the maximum load for two of the conical posts with glass fibers and a 229% increase for the carbon fiber posts in the cement without primer as compared with the cement with primer. Moreover, almost all the studied systems showed fracture resistances higher than the typical masticatory loads. The microscopic analysis underlined the good adhesion of the second cement at the interfaces between dentine and post. The mechanical tests confirmed that the strength of the dental systems subjected to masticatory loads was strictly related to the bond at the interface post/cement and cement/dentine. Copyright © 2013 Wiley Periodicals, Inc.
[Fiber-reinforced composite in fixed prosthodontics].
Pilo, R; Abu Rass, Z; Shmidt, A
2010-07-01
Fiber reinforced composite (FRC) is composed of resin matrix and fibers filler. Common types of fibers: polyethylene, carbon and glass. Fibers can be continuous and aligned, discontinuous and aligned, discontinuous and randomly oriented. The architecture of the fibers is unidirectional, woven or braided. The two main types are: dry fibers or impregnated. Inclusion of fibers to resin composite increased its average flexural strength in 100-200 MPa. FRC can be utilized by the dentist in direct approach (splinting, temporary winged bridge) or indirect approach (laboratory made fixed partial denture). Laboratory fixed partial denture (FPD) is made from FRC substructure and Hybrid/Microfill particulate composite veneer. Main indications: interim temporary FPD or FPD in cases of questionable abutment teeth, in aesthetic cases where All Ceram FPD is not feasible. Retention is attained by adhesive cementation to minimally prepared teeth or to conventionally prepared teeth; other options are inlay-onlay bridges or hybrid bridges. Contraindications are: poor hygiene, inability to control humidity, parafunction habits, and more than two pontics. Survival rate of FRC FPD over 5 years is 75%, lower compared to porcelain fused to metal FPD which is 95%. Main reasons for failure are: fracture of framework and delamination of the veneer. Part of the failures is repairable.
Acoustic emission analysis of fiber-reinforced composite in flexural testing.
Alander, Pasi; Lassila, Lippo V J; Tezvergil, Arzu; Vallittu, Pekka K
2004-05-01
The aim of this study was to examine the emission of acoustic signals from six commercially available fiber-reinforced composites (FRC) used in the frameworks of fixed partial dentures in material bending. FRC test specimens were made of six commercially available fiber products of polyethylene or glass and five light-curing resins. FRC test specimens were polymerized with a hand light-curing unit or with a light-curing oven. The flexural test for determination of ultimate flexural strength of test specimens (n = 6) was based on the ISO 10477 standard after the specimens were stored in air or in water for two weeks. The acoustic emission (AE) signals were monitored during three-point loading test of the test specimens using a test with increasing loading levels until the specimens fractured. Generally, stress level required for the AE activity initiation ranged from 107 MPa (Ribbond) to 579 MPa (everStick). The ultimate flexural strength of FRC specimens were higher, ranging from 132 to 764 MPa, being highest with everStick and Vectris FRC, and lowest with Ribbond FRC. ANOVA showed a statistically significant difference between the initiation of AE activity and the ultimate flexural strength according to the brand (p < 0.001) storing conditions (p < 0.001) and polymerization procedure (p < 0.001). AE activity and ultimate flexural strength correlated significantly (p < 0.010, r = 0.887). The result of this study suggested that AE activity in FRC specimens started at a 19-32% lower stress level than occurred at final fracture.
Ylä-Soininmäki, Anne; Moritz, Niko; Lassila, Lippo V J; Peltola, Matti; Aro, Hannu T; Vallittu, Pekka K
2013-12-01
The aim of this study was to characterize the microstructure and mechanical properties of porous fiber-reinforced composites (FRC). Implants made of the FRC structures are intended for cranial applications. The FRC specimens were prepared by impregnating E-glass fiber sheet with non-resorbable bifunctional bis-phenyl glycidyl dimethacrylate and triethylene glycol dimethacrylate resin matrix. Four groups of porous FRC specimens were prepared with a different amount of resin matrix. Control group contained specimens of fibers, which were bound together with sizing only. Microstructure of the specimens was analyzed using a micro computed tomography (micro-CT) based method. Mechanical properties of the specimens were measured with a tensile test. The amount of resin matrix in the specimens had an effect on the microstructure. Total porosity was 59.5 % (median) in the group with the lowest resin content and 11.2 % (median) in the group with the highest resin content. In control group, total porosity was 94.2 % (median). Correlations with resin content were obtained for all micro-CT based parameters except TbPf. The tensile strength of the composites was 21.3 MPa (median) in the group with the highest resin content and 43.4 MPa (median) in the group with the highest resin content. The tensile strength in control group was 18.9 MPa (median). There were strong correlations between the tensile strength of the specimens and most of the micro-CT based parameters. This experiment suggests that porous FRC structures may have the potential for use in implants for cranial bone reconstructions, provided further relevant in vitro and in vivo tests are performed.
Xie, Qiufei; Lassila, Lippo V J; Vallittu, Pekka K
2007-07-01
This in vitro study was aimed to compare the fracture resistance of directly fabricated inlay-retained fiber-reinforced composite (FRC) fixed partial dentures (FPDs) with four types of framework designs. Forty-eight directly fabricated inlay retained FPDs were made of FRC and particulate resin composite (everStick/Tetric flow and Ceram). Extracted human mandibular first premolars and first molars were as abutments. The following framework designs were tested: in the Group A (control group), the framework was made of two prepregs of unidirectional glass FRC; the Group B, two prepregs in pontic portion were covered with one layer of multidirectional fiber veil FRC; the Group C, the FRC prepregs were covered in pontic portion with four short unidirectional FRC pieces along the main prepregs; in Group D, one short unidirectional FRC prepregs were placed on the main prepregs in 90 degrees angle to the main framework. After thermal cycling, FPDs of each group (n=12) were randomly divided into two subgroups (n=6). Fracture test was performed at the universal testing machine (1mm/min) where FPDs were loaded from the occlusal direction to the occlusal fossa or to the buccal cusp. Failure patterns were observed with stereomicroscope. Median and 25%/75% percentile values were calculated and nonparametric analysis was performed. Compared with three other framework designs, the FPDs in Group D showed the highest resistance when loading to the occlusal fossa, with maximum load of 2,353.8N (25%/75%: 2,155.5/2,500.0) (p=0.000, 0.000, and 0.005 for compared with Group A, B, and C). The same group showed also higher resistance when loaded to the buccal cusp (1,416.3N (1,409.2/1,480.8)) if compared to the FPDs of the Group A and Group C (p=0.044, 0.010). In general the FPDs showed higher resistant to loading at the occlusal fossa (p<0.05). This in vitro study showed that inlay-retained FRC FPD constructed with direct technique provided high fracture resistance. The framework design that provided support for the veneering composite of the pontic contributed to the highest load-bearing capacity even when loaded to the buccal cusp.
Evaluation of some properties of two fiber-reinforced composite materials.
Lassila, Lippo V J; Tezvergil, Arzu; Lahdenperä, Milla; Alander, Pasi; Shinya, Akiyoshi; Shinya, Akikazu; Vallittu, Pekka K
2005-08-01
Water sorption, flexural properties, bonding properties, and elemental composition of photopolymerizable resin-impregnated fiber-reinforced composite (FRC) materials (everStick C&B and BR-100) (FPD) were evaluated in this study. Bar-shaped specimens (2 x 2 x 25 mm) were prepared for water sorption and flexural strength testing. The specimens (n = 6) were polymerized either with a hand light-curing unit for 40 s or, additionally, in a light-curing oven for 20 min and stored in water for 30 days. Water sorption was measured during this time, followed by measurements of flexural strength and modulus. A shear bond strength test was performed to determine the bonding characteristics of polymerized FRC to composite resin luting cement (Panavia-F), (n = 15). The cement was bonded to the FRC substrate and the specimens were thermocycled 5000 times (5-55 degrees C) in water. SEM/EDS were analyzed to evaluate the elemental composition of the glass fibers and the fiber distribution in cross section. ANOVA showed significant differences in water sorption according to brand (p < 0.05). Water sorption of everStick C&B was 1.86 wt% (hand-unit polymerized) and 1.94 wt% (oven polymerized), whereas BR-100 was 1.07 wt% and 1.17 wt%, respectively. The flexural strength of everStick C&B after 30 days' water storage was 559 MPa (hand-unit polymerized) and 796 MPa (oven-polymerized); for BR-100, the values were 547 MPa and 689 MPa, respectively. Mean shear bond strength of composite resin cement to the FRC varied between 20.1 and 23.7 MPa, showing no statistical difference between the materials. SEM/EDS analysis revealed that fibers of both FRC materials consist of the same oxides (SiO2, CaO, and Al2O3) in ratios. The distribution of fibers in the cross section of specimens was more evenly distributed in everStick C&B than in BR-100. The results of this study suggest that there are some differences in the tested properties of the FRC materials.
Tacir, Ibrahim H; Dirihan, Roda S; Polat, Zelal Seyfioglu; Salman, Gizem Ön; Vallittu, Pekka; Lassila, Lippo; Ayna, Emrah
2018-06-28
BACKGROUND The aim of this study was to investigate and compare the load-bearing capacities of three-unit direct resin-bonded fiber-reinforced composite fixed dental prosthesis with different framework designs. MATERIAL AND METHODS Sixty mandibular premolar and molar teeth without caries were collected and direct glass fiber-resin fixed FDPs were divided into 6 groups (n=10). Each group was restored via direct technique with different designs. In Group 1, the inlay-retained bridges formed 2 unidirectional FRC frameworks and pontic-reinforced transversal FRC. In Group 2, the inlay-retained bridges were supported by unidirectional lingual and occlusal FRC frameworks. Group 3, had buccal and lingual unidirectional FRC frameworks without the inlay cavities. Group 4 had reinforced inlay cavities and buccal-lingual FRC with unidirectional FRC frameworks. Group 5, had a circular form of fiber reinforcement around cusps in addition to buccal-lingual FRC frameworks. Group 6 had a circular form of fiber reinforcement around cusps with 2 bidirectional FRC frameworks into inlay cavities. All groups were loaded until final fracture using a universal testing machine at a crosshead speed of 1 mm/min. RESULTS Mean values of the groups were determined with ANOVA and Tukey HSD. When all data were evaluated, Group 6 had the highest load-bearing capacities and revealed significant differences from Group 3 and Group 4. Group 6 had the highest strain (p>0.05). When the fracture patterns were investigated, Group 6 had the durability to sustain fracture propagation within the restoration. CONCLUSIONS The efficiency of fiber reinforcement of the restorations alters not only the amount of fiber, but also the design of the restoration with fibers.
Chang, Hoon-Sang; Noh, Young-Sin; Lee, Yoon; Min, Kyung-San
2013-01-01
PURPOSE The aim of this study was to determine whether the push-out bond strengths between the radicular dentin and fiber reinforced-composite (FRC) posts with various resin cements decreased or not, according to the coronal, middle or apical level of the root. MATERIALS AND METHODS FRC posts were cemented with one of five resin cement groups (RelyX Unicem: Uni, Contax with activator & LuxaCore-Dual: LuA, Contax & LuxaCore-Dual: Lu, Panavia F 2.0: PA, Super-Bond C&B: SB) into extracted human mandibular premolars. The roots were sliced into discs at the coronal, middle and apical levels. Push-out bond strength tests were performed with a universal testing machine at a crosshead speed of 0.5 mm/min, and the failure aspect was analyzed. RESULTS There were no significant differences (P>.05) in the bond strengths of the different resin cements at the coronal level, but there were significant differences in the bond strengths at the middle and apical levels (P<.05). Only the Uni and LuA cements did not show any significant decrease in their bond strengths at all the root levels (P>.05); all other groups had a significant decrease in bond strength at the middle or apical level (P<.05). The failure aspect was dominantly cohesive at the coronal level of all resin cements (P<.05), whereas it was dominantly adhesive at the apical level. CONCLUSION All resin cement groups showed decreases in bond strengths at the middle or apical level except LuA and Uni. PMID:24049569
Mohammadzadeh, Zahra; Parisay, Iman; Mehrabkhani, Maryam; Madani, Azam Sadat; Mazhari, Fatemeh
2016-01-01
Objective: The aim of this study was to evaluate the clinical performance of tooth-colored fiber-reinforced composite (FRC) crowns in pulp-treated second primary mandibular teeth. Materials and Methods: This split-mouth randomized, clinical trial performed on 67 children between 3 and 6 years with two primary mandibular second molars requiring pulp treatment. After pulp therapy, the teeth were randomly assigned to stainless steel crown (SSC) or FRC crown groups. Modified United States Public Health Service criteria were used to evaluate marginal integrity, marginal discoloration, and secondary caries in FRC crowns at intervals of 3, 6, and 12 months. Retention rate and gingival health were also compared between the two groups. The data were analyzed using Friedman, Cochran, and McNemar's tests at a significance level of 0.05. Results: Intact marginal integrity in FRC crowns at 3, 6, and 12 months were 93.2%, 94.8%, and 94.2%, respectively. Marginal discoloration and secondary caries were not found at any of the FRC crowns. The retention rates of the FRC crowns were 100%, 98.3%, and 89.7% at 3, 6 and 12 months, respectively, whereas all the SSCs were found to be present and intact after 12 months (P = 0.016). There was no statistically significant difference between the two groups in gingival health. Conclusion: According to the results of this study, it seems that when esthetics is a concern, in cooperative patients with good oral hygiene, FRC crowns can be considered as a valuable procedure. PMID:28042269
Development and validation of a canine radius replica for mechanical testing of orthopedic implants.
Little, Jeffrey P; Horn, Timothy J; Marcellin-Little, Denis J; Harrysson, Ola L A; West, Harvey A
2012-01-01
To design and fabricate fiberglass-reinforced composite (FRC) replicas of a canine radius and compare their mechanical properties with those of radii from dog cadavers. Replicas based on 3 FRC formulations with 33%, 50%, or 60% short-length discontinuous fiberglass by weight (7 replicas/group) and 5 radii from large (> 30-kg) dog cadavers. Bones and FRC replicas underwent nondestructive mechanical testing including 4-point bending, axial loading, and torsion and destructive testing to failure during 4-point bending. Axial, internal and external torsional, and bending stiffnesses were calculated. Axial pullout loads for bone screws placed in the replicas and cadaveric radii were also assessed. Axial, internal and external torsional, and 4-point bending stiffnesses of FRC replicas increased significantly with increasing fiberglass content. The 4-point bending stiffness of 33% and 50% FRC replicas and axial and internal torsional stiffnesses of 33% FRC replicas were equivalent to the cadaveric bone stiffnesses. Ultimate 4-point bending loads did not differ significantly between FRC replicas and bones. Ultimate screw pullout loads did not differ significantly between 33% or 50% FRC replicas and bones. Mechanical property variability (coefficient of variation) of cadaveric radii was approximately 2 to 19 times that of FRC replicas, depending on loading protocols. Within the range of properties tested, FRC replicas had mechanical properties equivalent to and mechanical property variability less than those of radii from dog cadavers. Results indicated that FRC replicas may be a useful alternative to cadaveric bones for biomechanical testing of canine bone constructs.
Constitutive modeling of fiber-reinforced cement composites
NASA Astrophysics Data System (ADS)
Boulfiza, Mohamed
The role of fibers in the enhancement of the inherently low tensile stress and strain capacities of fiber reinforced cementitious composites (FRC) has been addressed through both the phenomenological, using concepts of continuum damage mechanics, and micro-mechanical approaches leading to the development of a closing pressure that could be used in a cohesive crack analysis. The observed enhancements in the matrix behavior is assumed to be related to the ability of the material to transfer stress across cracks. In the micromechanics approach, this is modeled by the introduction of a nonlinear closing pressure at the crack lips. Due to the different nature of cracking in the pre-peak and post peak regimes, two different micro-mechanical models of the cohesive pressure have been proposed, one for the strain hardening stage and another for the strain softening regime. This cohesive pressure is subsequently incorporated into a finite element code so that a nonlinear fracture analysis can be carried out. On top of the fact that a direct fracture analysis has been performed to predict the response of some FRC structural elements, a numerical procedure for the homogenization of FRC materials has been proposed. In this latter approach, a link is established between the cracking taking place at the meso-scale and its mechanical characteristics as represented by the Young's modulus. A parametric study has been carried out to investigate the effect of crack patterning and fiber volume fractions on the overall Young's modulus and the thermodynamic force associated with the tensorial damage variable. After showing the usefulness and power of phenomenological continuum damage mechanics (PCDM) in the prediction of ERC materials' response to a stimuli (loading), a combined PCDM-NLFMsp1 approach is proposed to model (predict, forecast) the complete response of the composite up to failure. Based on experimental observations, this approach assumes that damage mechanics which predicts a diffused damage is more appropriate in the pre-peak regime whereas, NLFM is more suitable in the post-peak stage where the opening and propagation of a major crack will control the response of the material and not a deformation in a continuum sense as opposed to the pre-cracking zone. Tensile and compressive tests have been carried out for the sole purpose of calibrating the constitutive models proposed and/or developed in this thesis for FRC materials. The suitability of the models in predicting the response of different structural members has been performed by comparing the models' forecasts with experimental results carried out by the author, as well as experimental results from the literature. The different models proposed in this thesis have the possibility to account for the presence of fibers in the matrix, and give fairly good results for both high fiber volume fractions (vsb{f}≥2%) and low fiber volume fractions (vsb{f}<2%). Use of interface elements in a finite element code has been shown to be a powerful tool in analyzing the behavior of concrete substrate-FRC repair materials by the introduction of a zero thickness layer of interface elements to account for the interface properties which usually control the effectiveness of the repair material. ftnsp1NLFM: Non Linear Fracture Mechanics.
Replacement of missing teeth with fiber-reinforced composite FPDs: clinical protocol.
Bouillaguet, Serge; Schütt, Andrea; Marin, Isabelle; Etechami, Leila; Di Salvo, Giancarlo; Krejci, Ivo
2003-04-01
The concept of minimally invasive preparation protocols has resulted in reduced loss of critical tooth structures and maintenance of optimal strength, form, and aesthetics. While various treatment options have been described for single-tooth replacement, fiber-reinforced composite (FRC) fixed partial dentures (FPDs) provide a viable treatment alternative with proven mechanical properties, aesthetics, and function. This article presents several clinical scenarios in which minimally invasive adhesive FRC FPDs are provided to deliver enhanced predictability, strength, and durability.
A fiber-reinforced composite prosthesis restoring a lateral midfacial defect: a clinical report.
Kurunmäki, Hemmo; Kantola, Rosita; Hatamleh, Muhanad M; Watts, David C; Vallittu, Pekka K
2008-11-01
This clinical report describes the use of a glass fiber-reinforced composite (FRC) substructure to reinforce the silicone elastomer of a large facial prosthesis. The FRC substructure was shaped into a framework and embedded into the silicone elastomer to form a reinforced facial prosthesis. The prosthesis is designed to overcome the disadvantages associated with traditionally fabricated prostheses; namely, delamination of the silicone of the acrylic base, poor marginal adaptation over time, and poor simulation of facial expressions.
Mitov, Gergo; Draenert, Florian; Schumann, Paul; Stötzer, Marcus; von See, Constantin
2016-12-01
We assessed the influence of a simulated diving environment on the interfacial microleakage and retentive forces of different post types in root-canal-filled teeth. One-hundred-and-twenty extracted, single-rooted teeth were endodontically treated and were randomly divided into three groups according to the post and cement used: ER Post/Harvard cement (Titanium), CeraPost/DentinBuild Evo (Zirconia), DT Light Post/Calibra (FRC). Each group was randomly divided into two equal subgroups, a control group, and an experimental group, subjected to simulated dives to 456 kPa in a diving chamber. For 10 specimens of each subgroup the pull-out strength and the coronal microleakage were measured. Significant differences in the linear coronal penetration were observed between the Titanium and FRC groups (experimental group P ≤ 0.001; control group P = 0.02). Diving simulation had no significant impact on the microleakage for the three post types. The FRC groups showed significantly higher retentive strength values compared to the Titanium and Zirconia groups before and after simulated diving. The pull-out strength of the titanium experimental group was significantly less than the control group (P = 0.008). Following root canal treatment the combination of fibre-reinforced posts and resin cement should be preferred for patients requiring retention for tooth restorations using posts that are likely to be exposed to hyperbaric conditions.
In vitro validation of a shape-optimized fiber-reinforced dental bridge.
Chen, YungChung; Li, Haiyan; Fok, Alex
2011-12-01
To improve its mechanical performance, structural optimization had been used in a previous study to obtain an alternative design for a 3-unit inlay-retained fiber-reinforced composite (FRC) dental bridge. In that study, an optimized layout of the FRC substructure had been proposed to minimize stresses in the veneering composite and interfacial stresses between the composite and substructure. The current work aimed to validate in vitro the improved fracture resistance of the optimized design. All samples for the 3-unit inlay-retained FRC dental bridge were made with glass-fibers (FibreKor) as the substructure, surrounded by a veneering composite (GC Gradia). Two different FRC substructure designs were prepared: a conventional (n=20) and an optimized design (n=21). The conventional design was a straight beam linking one proximal box to the other, while the optimized design was a curved beam following the lower outline of the pontic. All samples were loaded to 400N on a universal test machine (MTS 810) with a loading speed of 0.2mm/min. During loading, the force and displacement were recorded. Meanwhile, a two-channel acoustic emission (AE) system was used to monitor the development of cracks during loading. The load-displacement curves of the two groups displayed significant differences. For the conventional design, there were numerous drops in load corresponding to local damage of the sample. For the optimized design, the load curves were much smoother. Cracks were clearly visible on the surface of the conventional group only, and the directions of those cracks were perpendicular to those of the most tensile stresses. Results from the more sensitive AE measurement also showed that the optimized design had, on average, fewer cracking events: 38 versus 2969 in the conventional design. The much lower number of AE events and smoother load-displacement curves indicated that the optimized FRC bridge design had a higher fracture resistance. It is expected that the optimized design will significantly improve the clinical performance of FRC bridges. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Jurukovska-Shotarovska, Vesna; Kapusevska, Biljana
2015-01-01
To make a comparative analysis of the mechanical properties between FRC and zirconium posts Methods: The patients with FRC and zirconium posts were divided in two groups with three subgroups, each of them composed of 10 samples. Subgroup I with 1.2 mm; Subgroup II with 1.35 mm and Subgroup III with 1.5 mm post diameter. The fracture force, bending and tensile strength of each group were measured with Shimadzu Universal Testing Machine. The fracture force for the first group measured in the first, second and third subgroup was 34.80900N; 67.15390N; 46.53100N and for the second group, first, second and third subgroup was 34.80900N; 46.53100N; 67.15390N correspondingly. The bending strength for the first group measured in the first, second and third subgroup was 401.4420N; 444.6425N; 333.6828N and for the second group, first, second and third subgroup was 307.9352N; 289.1030N; 304.1649N correspondingly. The tensile strength for the first group measured in the first, second and third subgroup was 5.442267N; 4.350545N; 2.943465N and for the second group, first, second and third subgroup was 4.224141N; 3.751466N; 3.168756N correspondingly. The longest diameter of the posts significantly increases the resistance to fracture in relation to the two smaller diameters. The larger diameter, the higher values of the bending strength, as well as the lowest values of the tensile strength of the material contribute to improved mechanical properties of the fiber and zirconium posts.
Khan, Aftab A; Al-Kheraif, Abdulaziz A; Al-Shehri, Abdullah M; Säilynoja, Eija; Vallittu, Pekka K
2018-02-01
This laboratory study was aimed to characterize semi-interpenetrating polymer network (semi-IPN) of fiber-reinforced composite (FRC) prepregs that had been stored for up to two years before curing. Resin impregnated prepregs of everStick C&B (StickTech-GC, Turku, Finland) glass FRC were stored at 4°C for various lengths of time, i.e., two-weeks, 6-months and 2-years. Five samples from each time group were prepared with a light initiated free radical polymerization method, which were embedded to its long axis in self-curing acrylic. The nanoindentation readings on the top surface toward the core of the sample were made for five test groups, which were named as "stage 1-5". To evaluate the nanohardness and modulus of elasticity of the polymer matrix, a total of 4 slices (100µm each) were cut from stage 1 to stage 5. Differences in nanohardness values were evaluated with analysis of variance (ANOVA), and regression model was used to develop contributing effect of the material's different stages to the total variability in the nanomechanical properties. Additional chemical and thermal characterization of the polymer matrix structure of FRC was carried out. It was hypothesized that time of storage may have an influence on the semi-IPN polymer structure of the cured FRC. The two-way ANOVA test revealed that the storage time had no significant effect on the nanohardness of FRC (p = 0.374). However, a highly significant difference in nanohardness values was observed between the different stages of FRC (P<0.001). The regression coefficient suggests nanohardness increased on average by 0.039GPa for every storage group. The increased nanohardness values in the core region of 6-months and 2-years stored prepregs might be due to phase-segregation of components of semi-IPN structure of FRC prepregs before their use. This may have an influence to the surface bonding properties of the cured FRC. Copyright © 2017 Elsevier Ltd. All rights reserved.
Takahashi, Yutaka; Yoshida, Kaneyoshi; Shimizu, Hiroshi
2011-07-01
Objective. To evaluate the effect of the location of glass fiber-reinforced composite (FRC) reinforcement on the flexural load at the proportional limit (FL-PL) and the flexural deflection of a maxillary acrylic resin complete denture. Material and methods. Maxillary acrylic resin complete dentures strengthened with and without FRC reinforcement were tested. The polymerized FRC was embedded in the denture base resin in the doughy state and placed (1) under the ridge lap region, (2) in the anterior region, (3) in the middle region or (4) in the anterior and posterior regions. The FL-PL and flexural deflection value at the 100-N loading point of the reinforced maxillary denture specimens were tested. Results. All of the reinforced dentures had a higher FL-PL than the denture without reinforcement but the FL-PL values of all the dentures were not significantly different from each other. The efficiency of the FRC reinforcement compared to the unreinforced denture was 1.54-1.75 times greater. All of the reinforced dentures showed significantly lower deflection compared to the unreinforced denture, but the flexural deflections of all the dentures were not significantly different from each other. Conclusions. The location of the FRC reinforcement did not affect the fracture resistance of the maxillary acrylic resin complete denture. All of the reinforced dentures had higher FL-PL and lower flexural deflection than the denture without reinforcement.
Fiber-reinforced composite fixed dental prostheses: two clinical reports.
Zarow, Maciej; Paisley, Carl Stuart; Krupinski, Jerzy; Brunton, Paul Anthony
2010-06-01
Various options are available in clinical practice for the replacement of a single missing tooth, ranging from conventional fixed and removable dental prostheses to a single implant-supported crown. There are situations in which a semipermanent fixed dental prosthesis may be desirable, particularly for patients who have completed orthodontic treatment but are too young to embark on implant therapy. Following advances in fiber-reinforcement technology, fiber-reinforced composite resin (FRC) now represents a lower-cost alternative to traditional metal-ceramic for the construction of resin-bonded prostheses. Two case reports illustrate the use of FRC prostheses as fixed semipermanent_restorations.
Soares, L P; de Vasconcellos, A B; da Silva, A H Monteiro da Fonseca Thomé; Sampaio, E M; Vianna, G A de Deus Carneiro
2010-12-01
The aim of this study was to investigate the flexural properties of five types of fiber-reinforced dowels using a modified three-point bending test. Fiber-reinforced resin dowels were tested by a modified three-point bending test associated with models for cylindrical and conical simple-supported beams. The fracture load ranged from 86 to 246 N and the flexural strength from 423 to 1192 MPa. FRC Postec had significantly higher flexural strength and fracture loads values. Thus, the present study demonstrated higher flexural strength values for the FRC Postec fibre posts, suggesting that this system would present a better response to the forces of mastication.
Ozcan, Mutlu; Breuklander, Marijn H; Vallittu, Pekka K
2005-04-01
Nonstandardized box dimensions for inlay-retained fixed partial dentures (FPDs) may result in uneven distribution of the forces on the connector region of such restorations. The objective of this in vitro study was to evaluate the effect of box dimensions on the initial and final failure strength of inlay-retained fiber-reinforced composite (FRC) FPDs. Twenty-one inlay-retained FPDs were prepared using FRC (everStick) frameworks with unidirectional fiber reinforcement between mandibular first premolars and first molars. Boxes were prepared using conventional inlay burs (Cerinlay), and small and large ultrasonic tips (SONICSYS approx). Box dimensions were measured after preparation with a digital micrometer. All restorations were subjected to thermal cycling (6000 cycles, 5 degrees C-55 degrees C). Fracture testing was performed in a universal testing machine (1 mm/min). Acoustic emission signals were monitored during loading of the specimens. Initial and final fracture strength values (2-way ANOVA, Bonferroni post hoc tests, alpha =.05) and failure types (Fisher exact test) were statistically compared for each group. Significant differences (P =.0146 and P =.0086) were observed between the groups in the dimensions of the boxes prepared using conventional burs buccolingually (2.8-3.0 mm in molars, 3.1-4.3 mm in premolars) and the small size (2.5-2.9, 2.9-3.8 mm) or large size (2.6-3.8, 3.2-4.9 mm) ultrasonic tips for the premolars and the molars, respectively. No significant differences were found at the initial and final failures between the conventionally prepared group (842 +/- 267 N, 1161 +/- 428 N) and those prepared with either small (1088 +/- 381 N, 1320 +/- 380 N) or large ultrasonic tips (1070 +/- 280 N, 1557 +/- 321 N), respectively. The failure analysis demonstrated no significant difference in failure types but predominant delamination of the veneering resin (85%) in all experimental groups. According to acoustic emission tests, a higher energy level was required for final failure of the FRC FPDs with boxes finished using small ultrasonic tips. Standardized box dimensions showed no significant effect on fracture strength at either initial or final failure of the fiber-reinforced FPDs. The FRC FPDs with boxes refined with small ultrasonic burs required a greater energy level before failure. The type of failure observed after the fracture tests was primarily delamination of the veneering resin.
Mechanical properties and ultrastructural characteristics of a glass fiber-reinforced composite.
García Barbero, Alvaro Enrique; Vera González, Vicente; García Barbero, Ernesto; Aliaga Vera, Ignacio
2015-06-01
To examine the ultrastructural characteristics of a fiber-reinforced composite (FRC) and its behavior in vitro as a framework for fixed partial dentures (FPDs). A total of 40 specimens were prepared using extracted teeth fixed in methacrylate blocks as supports for the FPD, then the specimens were divided into four groups depending on whether a retaining box was used to fix the FPD to the support teeth, and on whether a composite pontic was assembled on top of the fibers. Fracture testing was performed in a universal testing machine (1 mm/minute). Fracture strength values and failure types were statistically compared for each group. Using retaining boxes did not improve the mechanical behavior of the restorative system. The weakest element of the system was the composite tooth constructed on top of the FRC.
Fiberglass distribution poles: A case study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, M.F.; Hosford, G.S.; Boozer, J.F. III
1995-01-01
This paper addresses the design considerations and manufacturing techniques along with mechanical test results of fiberglass reinforced composite (FRC) primary distribution poles. With it`s light weight, and virtually no maintenance it offers a viable alternative for use in remote and inaccessible locations. This paper also discusses a case study where seventy five FRC primary distribution poles have been installed on a distribution system in a remote area accessible only by foot and helicopter.
Advanced Fuels Reactor using Aneutronic Rodless Ultra Low Aspect Ratio Tokamak Hydrogenic Plasmas
NASA Astrophysics Data System (ADS)
Ribeiro, Celso
2015-11-01
The use of advanced fuels for fusion reactor is conventionally envisaged for field reversed configuration (FRC) devices. It is proposed here a preliminary study about the use of these fuels but on an aneutronic Rodless Ultra Low Aspect Ratio (RULART) hydrogenic plasmas. The idea is to inject micro-size boron pellets vertically at the inboard side (HFS, where TF is very high and the tokamak electron temperature is relatively low because of profile), synchronised with a proton NBI pointed to this region. Therefore, p-B reactions should occur and alpha particles produced. These pellets will act as an edge-like disturbance only (cp. killer pellet, although the vertical HFS should make this less critical, since the unablated part should appear in the bottom of the device). The boron cloud will appear at midplance, possibly as a MARFE-look like. Scaling of the p-B reactions by varying the NBI energy should be compared with the predictions of nuclear physics. This could be an alternative to the FRC approach, without the difficulties of the optimization of the FRC low confinement time. Instead, a robust good tokamak confinement with high local HFS TF (enhanced due to the ultra low aspect ratio and low pitch angle) is used. The plasma central post makes the RULART concept attractive because of the proximity of NBI path and also because a fraction of born alphas will cross the plasma post and dragged into it in the direction of the central plasma post current, escaping vertically into a hole in the bias plate and reaching the direct electricity converter, such as in the FRC concept.
Glass fibre-reinforced composite laced with chlorhexidine digluconate and yeast adhesion.
Waltimo, T; Luo, G; Samaranayake, L P; Vallittu, P K
2004-02-01
The aim of this study was to lace dental glass fibre reinforced composite (FRC) prepreg with chlorhexidine digluconate and to examine the adherence of common oral fungal pathogen Candida albicans to FRC made of the prepreg. Four different test and control material groups each comprising 16 test specimens ((5.0 x 5.0 x 0.8) mm3) each were used as substrates for C. albicans adherence. A porous polymer pre-impregnated woven glass fibre prepreg was laced with solution of chlorhexidine gluconate and it was used with autopolymerized denture base polymer to fabricate FRC test specimens. Control group (Group 1) consisted of FRC test specimens stored in water. In Group 2, the test specimens were stored in 10% chlorhexidine digluconate solution for 24 h. Group 3 consisted of specimens fabricated using such fibre reinforcements which were pre-soaked in 20% chlorhexidine digluconate and dried before preparation with denture base resin, and followed by storage of the specimens in water. Group 4 was similar to Group 3 but instead of water storage the specimens were immersed in 10% chlorhexidine digluconate for 24 h. For the candidal adhesion assay the test and control specimens were incubated in standardized suspensions of four different strains of C. albicans, rinsed and prepared for light-microscopy. The mean number of adherent cells in each group was counted microscopically and analysed statistically. There were significantly (P < 0.05) more adherent C. albicans cells found in Group 1 than in the other three groups which did not differ significantly from each other. The lowest numbers of adherent cells were found in Group 3. Pretreating the porous polymer pre-impregnated glass fibre reinforcement with chlorhexidine digluconate result in reduction in the number of adherent yeast cells on the surface FRC material.
Nganga, Sara; Zhang, Di; Moritz, Niko; Vallittu, Pekka K; Hupa, Leena
2012-11-01
Glass-fiber-reinforced composites (FRCs), based on bifunctional methacrylate resin, have recently shown their potential for use as durable cranioplasty, orthopedic and oral implants. In this study we suggest a multi-component sandwich implant structure with (i) outer layers out of porous FRC, which interface the cortical bone, and (ii) inner layers encompassing bioactive glass granules, which interface with the cancellous bone. The capability of Bioglass(®) 45S5 granules (100-250μm) to induce calcium phosphate formation on the surface of the FRC was explored by immersing the porous FRC-Bioglass laminates in simulated body fluid (SBF) for up to 28d. In both static (agitated) and dynamic conditions, bioactive glass granules induced precipitation of calcium phosphate at the laminate surfaces as confirmed by scanning electron microscopy. The proposed dynamic flow system is useful for the in vitro simulation of bone-like apatite formation on various new porous implant designs containing bioactive glass and implant material degradation. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
C. P. Pantelides; T. T. Garfield; W. D. Richins
2012-03-01
The paper presents experimental data generated for calibrating finite element models to predict the performance of reinforced concrete panels with a wide range of construction details under blast loading. The specimens were 1.2 m square panels constructed using Normal Weight Concrete (NWC) or Fiber Reinforced Concrete (FRC). FRC consisted of macro-synthetic fibers dispersed in NWC. Five types of panels were tested: NWC panels with steel bars; FRC panels without additional reinforcement; FRC panels with steel bars; NWC panels with glass fiber reinforced polymer (GFRP) bars; and NWC panels reinforced with steel bars and external GFRP laminates on both faces. Eachmore » panel type was constructed with three thicknesses: 152 mm, 254 mm, and 356 mm. FRC panels with steel bars had the best performance for new construction. NWC panels reinforced with steel bars and external GFRP laminates on both faces had the best performance for strengthening or rehabilitation of existing structures. The performance of NWC panels with GFRP bars was strongly influenced by the bar spacing. The behavior of the panels is classified in terms of damage using immediate occupancy, life safety, and near collapse performance levels. Preliminary dynamic simulations are compared to the experimental results.« less
3D-WOVEN FIBER-REINFORCED COMPOSITE FOR CAD/CAM DENTAL APPLICATION
Petersen, Richard; Liu, Perng-Ru
2016-01-01
Three-dimensional (3D)-woven noncrimp fiber-reinforced composite (FRC) was tested for mechanical properties in the two principal directions of the main XY plane and compared to different Computer-Aided-Design/Computer-Aided-Machining (CAD/CAM) Dental Materials. The Dental Materials included ceramic with Vitablock Mark II®, ProCAD®, InCeram® Spinel, InCeram® Alumina and InCeram® Zirconia in addition to a resin-based 3M Corp. Paradigm® particulate-filled composite. Alternate material controls included Coors 300 Alumina Ceramic and a tungsten carbide 22% cobalt cermet. The 3D-woven FRC was vacuum assisted resin transfer molding processed as a one-depth-thickness ~19-mm preform with a vinyl-ester resin and cut into blocks similar to the commercial CAD/CAM Dental Materials. Mechanical test samples prepared for a flexural three-point span length of 10.0 mm were sectioned for minimum-depth cuts to compare machinability and fracture resistance between groups. 3D-woven FRC improved mechanical properties with significant statistical differences over all CAD/CAM Dental Materials and Coors Alumina Ceramic for flexural strength (p<0.001), resilience (p<0.05), work of fracture (p<0.001), strain energy release (p<0.05), critical stress intensity factor (p<0.001) and strain (p<0.001). PMID:27642198
3D-WOVEN FIBER-REINFORCED COMPOSITE FOR CAD/CAM DENTAL APPLICATION.
Petersen, Richard; Liu, Perng-Ru
2016-05-01
Three-dimensional (3D)-woven noncrimp fiber-reinforced composite (FRC) was tested for mechanical properties in the two principal directions of the main XY plane and compared to different Computer-Aided-Design/Computer-Aided-Machining (CAD/CAM) Dental Materials. The Dental Materials included ceramic with Vitablock Mark II®, ProCAD®, InCeram® Spinel, InCeram® Alumina and InCeram® Zirconia in addition to a resin-based 3M Corp. Paradigm® particulate-filled composite. Alternate material controls included Coors 300 Alumina Ceramic and a tungsten carbide 22% cobalt cermet. The 3D-woven FRC was vacuum assisted resin transfer molding processed as a one-depth-thickness ~19-mm preform with a vinyl-ester resin and cut into blocks similar to the commercial CAD/CAM Dental Materials. Mechanical test samples prepared for a flexural three-point span length of 10.0 mm were sectioned for minimum-depth cuts to compare machinability and fracture resistance between groups. 3D-woven FRC improved mechanical properties with significant statistical differences over all CAD/CAM Dental Materials and Coors Alumina Ceramic for flexural strength (p<0.001), resilience (p<0.05), work of fracture (p<0.001), strain energy release (p<0.05), critical stress intensity factor (p<0.001) and strain (p<0.001).
Mangine, Gerald T; Hoffman, Jay R; Wang, Ran; Gonzalez, Adam M; Townsend, Jeremy R; Wells, Adam J; Jajtner, Adam R; Beyer, Kyle S; Boone, Carleigh H; Miramonti, Amelia A; LaMonica, Michael B; Fukuda, David H; Ratamess, Nicholas A; Stout, Jeffrey R
2016-12-01
To compare the effects of two different resistance training programs, high intensity (INT) and high volume (VOL), on changes in isometric force (FRC), rate of force development (RFD), and barbell velocity during dynamic strength testing. Twenty-nine resistance-trained men were randomly assigned to either the INT (n = 15, 3-5 RM, 3-min rest interval) or VOL (n = 14, 10-12 RM, 1-min rest interval) training group for 8 weeks. All participants completed a 2-week preparatory phase prior to randomization. Measures of barbell velocity, FRC, and RFD were performed before (PRE) and following (POST) the 8-week training program. Barbell velocity was determined during one-repetition maximum (1RM) testing of the squat (SQ) and bench press (BP) exercises. The isometric mid-thigh pull was used to assess FRC and RFD at specific time bands ranging from 0 to 30, 50, 90, 100, 150, 200, and 250 ms. Analysis of covariance revealed significant (p < 0.05) group differences in peak FRC, FRC at 30-200 ms, and RFD at 50-90 ms. Significant (p < 0.05) changes in INT but not VOL in peak FRC (INT: 9.2 ± 13.8 %; VOL: -4.3 ± 10.2 %), FRC at 30-200 ms (INT: 12.5-15.8 %; VOL: -1.0 to -4.3 %), and RFD at 50 ms (INT: 78.0 ± 163 %; VOL: -4.1 ± 49.6 %) were observed. A trend (p = 0.052) was observed for RFD at 90 ms (INT: 58.5 ± 115 %; VOL: -3.5 ± 40.1 %). No group differences were observed for the observed changes in barbell velocity. Results indicate that INT is more advantageous than VOL for improving FRC and RFD, while changes in barbell velocity during dynamic strength testing are similarly improved by both protocols in resistance-trained men.
PERFORMANCE OF RC AND FRC WALL PANELS REINFORCED WITH MILD STEEL AND GFRP COMPOSITES IN BLAST EVENTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Timothy Garfield; William D. Richins; Thomas K. Larson
The structural integrity of reinforced concrete structures in blast events is important for critical facilities. This paper presents experimental data generated for calibrating detailed finite element models that predict the performance of reinforced concrete wall panels with a wide range of construction details under blast loading. The test specimens were 1.2 m square wall panels constructed using Normal Weight Concrete (NWC) or Fiber Reinforced Concrete (FRC). FRC consists of macro-synthetic fibers dispersed in NWC. Five types of panels were tested: NWC panels with steel bar reinforcement (Type A); FRC panels without additional reinforcement (Type B); FRC panels with steel barmore » reinforcement (Type C); NWC panels with glass fiber reinforced polymer (GFRP) bar reinforcement (Type D); and NWC panels reinforced with steel bar reinforcement and external bidirectional GFRP overlays on both faces (Type E). An additional three Type C panels were used as control specimens (CON). Each panel type was constructed with three thicknesses: 152 mm, 254 mm, and 356 mm. The panels were instrumented with strain gauges, and accelerometers; in addition, pressure sensors and high speed videos were employed during the blast events. Panel types C and E had the best performance, whereas panel type B did not perform well. Preliminary dynamic simulations show crack patterns similar to the experimental results.« less
Sewón, L A; Ampula, L; Vallittu, P K
2000-08-01
The present case report describes a 1-year follow-up of functional rehabilitation of a young periodontal patient with severely advanced, rapidly progressing marginal bone loss treated by using a new splinting material, i.e., glass fiber-reinforced composite (FRC). Apart from one single tooth, the young man had retained all his natural teeth. Periodontal treatment was based on cleaning and root planing enabled by partial-thickness-flap operations. This method was selected to avoid further damage to the remaining alveolar bone. After healing for 6 months, a cavity retained internal FRC splint was constructed and 1 missing lower molar was replaced by an inlay-retained FRC resin-bonded fixed partial denture (FPD). A 12 months follow-up period revealed a healthy periodontium and good functional and esthetic results. The new material allows the use of periodontal treatment methods instead of prosthetic alternatives, which until now have been a more generally used approach in the treatment of severely advanced periodontal cases. Internal fiber-reinforced composite splinting being affordable for the patient, easy for the clinician to construct and giving good esthetic and functional results, suggests that the method may be a valuable aid in periodontal treatment.
Lorenzoni, Fabio Cesar; Bonfante, Estevam A; Bonfante, Gerson; Martins, Leandro M; Witek, Lukasz; Silva, Nelson R F A
2013-08-01
This evaluation aimed to (1) validate micro-computed tomography (microCT) findings using scanning electron microscopy (SEM) imaging, and (2) quantify the volume of voids and the bonded surface area resulting from fiber-reinforced composite (FRC) dowel cementation technique using microCT scanning technology/3D reconstructing software. A fiberglass dowel was cemented in a condemned maxillary lateral incisor prior to its extraction. A microCT scan was performed of the extracted tooth creating a large volume of data in DICOM format. This set of images was imported to image-processing software to inspect the internal architecture of structures. The outer surface and the spatial relationship of dentin, FRC dowel, cement layer, and voids were reconstructed. Three-dimensional spatial architecture of structures and volumetric analysis revealed that 9.89% of the resin cement was composed of voids and that the bonded area between root dentin and cement was 60.63% larger than that between cement and FRC dowel. SEM imaging demonstrated the presence of voids similarly observed using microCT technology (aim 1). MicroCT technology was able to nondestructively measure the volume of voids within the cement layer and the bonded surface area at the root/cement/FRC interfaces (aim 2). The interfaces at the root dentin/cement/dowel represent a timely and relevant topic where several efforts have been conducted in the past few years to understand their inherent features. MicroCT technology combined with 3D reconstruction allows for not only inspecting the internal arrangement rendered by fiberglass adhesively bonded to root dentin, but also estimating the volume of voids and contacted bond area between the dentin and cement layer. © 2013 by the American College of Prosthodontists.
Torabi, Kianoosh; Rasaeipour, Sasan; Khaledi, Amir Alireza; Vojdani, Mahroo; Ghodsi, Safoura
2014-05-01
Pressing esthetic demands of good looking make people undergo bleaching procedures. However, the effect of bleaching agents on esthetic restorative materials with different surface preparations has been poorly studied. The aim of this study was to examine the effect of a homebleaching agent (carbamide peroxide: CP 38%) on the surface roughness of the polished fiber reinforced composite (FRC), overglazed, autoglazed, or polished ceramic samples. Twenty standardized cylindrical specimens were made of each of the following groups: over-glazed, autoglazed, polished porcelain and also FRC. The test specimens exposed to the CP 38%, 15 minutes, twice a day for 2 weeks according to the manufacturer's recommendation. Six samples from each group were selected randomly to form negative controls. Surface roughness measurements (Ra, micrometer) for baseline, test and control specimens were performed by use of a profilometer. Paired t-test, Mann-Whitney test, and Kruskal-Wallis test were used for statistical analyses. The data showed that bleaching with CP 38% significantly increased the surface roughness of all the test samples (p < 0.05). The type of surface preparation caused significant differences between the susceptibility of porcelain subgroups to bleaching (p < 0.05). The polished porcelain specimens showed the highest changes after bleaching. CP 38% significantly increases the surface roughness of the porcelains and FRC. The type of surface condition affects the amenability of the porcelain surface to the bleaching agent. Glazed porcelains were more resistant to roughness than the polished porcelains and also the composite. Roughening of porcelain and FRC occur following bleaching procedure. No special surface preparation of indirect esthetic restorative materials can completely preserve these materials from adverse effects of bleaching agents.
Yokoyama, Daiichiro; Shinya, Akikazu; Gomi, Harunori; Vallittu, Pekka K; Shinya, Akiyoshi
2012-01-01
Using finite element analysis (FEA), this study investigated the effects of the mechanical properties of adhesive resin cements on stress distributions in fiber-reinforced resin composite (FRC) adhesive fixed partial dentures (AFPDs). Two adhesive resin cements were compared: Super-Bond C&B and Panavia Fluoro Cement. The AFPD consisted of a pontic to replace a maxillary right lateral incisor and retainers on a maxillary central incisor and canine. FRC framework was made of isotropic, continuous, unidirectional E-glass fibers. Maximum principal stresses were calculated using finite element method (FEM). Test results revealed that differences in the mechanical properties of adhesive resin cements led to different stress distributions at the cement interfaces between AFPD and abutment teeth. Clinical implication of these findings suggested that the safety and longevity of an AFPD depended on choosing an adhesive resin cement with the appropriate mechanical properties.
Zhou, Xia; Peng, Yaozong; Li, Ling; He, Kai; Huang, Tao; Mou, Shaoxia; Feng, Min; Han, Bing; Ye, Xiaoli; Li, Xuegang
2016-05-01
The effects of fibrous root of Rhizoma Coptidis (FRC) and its main alkaloids on non-specific immunity and disease resistance of common carp were investigated. The fish were randomly assigned to seven groups: normal control group (NC), groups treated with 12.5 g/kg FRC (FRC-L), 25 g/kg FRC (FRC-M), 50 g/kg FRC (FRC-H), 0.78 g/kg total alkaloids (TA), 0.78 g/kg berberine (BBR), and 0.78 g/kg coptisine (Cop), respectively. Results showed that the activities of myeloperoxidase, lysozyme and respiratory burst were significantly elevated after treated with FRC-M, FRC-H, TA, BBR and Cop, and the complement C3 level and phagocytic activity were significantly increased in FRC-M, TA and BBR treated groups compared with NC group. The real-time PCR analysis indicated that FRC, TA, BBR and Cop could up-regulate the mRNA expression of IL-1β, TNF-α, lysozyme-c and C3, but down-regulate that of IL-10 in the head kidney of common carp. Besides, FRC-M, FRC-H, TA, BBR and Cop significantly enhanced the survival rate of common carp infected with Aeromonas hydrophila, when compared to NC group. It was concluded that the FRC could enhance the non-specific immunity and disease resistance of common carp and the main alkaloids might contribute to these effects. Copyright © 2016 Elsevier B.V. All rights reserved.
Zamboni, Sandra C; Baldissara, Paolo; Pelogia, Fernanda; Bottino, Marco Antonio; Scotti, Roberto; Valandro, Luiz Felipe
2008-01-01
This study evaluated the effect of post surface conditioning on the fatigue resistance of bovine teeth restored with resin-bonded fiber-reinforced composite (FRC). Root canals of 20 single-rooted bovine teeth (16 mm long) were prepared to 12 mm using a preparation drill of a double-tapered fiber post system. Using acrylic resin, each specimen was embedded (up to 3.0 mm from the cervical part of the specimen) in a PVC cylinder and allocated into one of two groups (n = 10) based on the post surface conditioning method: acid etching plus silanization or tribochemical silica coating (30 pm SiO(x) + silanization). The root canal dentin was etched (H2PO3 for 30 seconds), rinsed, and dried. A multi-step adhesive system was applied to the root dentin and the fiber posts were cemented with resin cement. The specimens were submitted to one million fatigue cycles. After fatigue testing, a score was given based on the number of fatigue cycles until fracture. All of the specimens were resistant to fatigue. No fracture of the root or the post and no loss of retention of the post were observed. The methodology and the results of this study indicate that tribochemical silica coating and acid etching performed equally well when dynamic mechanical loading was used.
Composite Bus Structure for the SMEX/WIRE Satellite
NASA Technical Reports Server (NTRS)
Rosanova, Giulio G.
1998-01-01
In an effort to reduce the weight and optimize the structural design of the Small Explorer (SMEX) Wide-Field Infrared Explorer (WIRE) spacecraft, it has become desirable to change the material and construction from mechanically fastened aluminum structure to a fully bonded fiber-reinforced composite (FRC) structure. GSFC has developed the WIRE spacecraft structural bus design concept, including the instrument and launch vehicle requirements. The WIRE Satellite is the fifth of a series of SMEX satellites to be launched once per year. GSFC has chosen Composite Optics Inc. (COI) as the prime contractor for the development and procurement of the WIRE composite structure. The detailed design of the fully bonded FRC structure is based on COI's Short Notice Accelerated Production SATellite ("SNAPSAT") approach. SNAPSAT is a state of the art design and manufacturing technology for advanced composite materials which utilizes flat-stock detail parts bonded together to produce a final structural assembly. The structural design approach adopted for the WIRE structure provides a very viable alternative to both traditional aluminum construction as well as high tech. molded type composite structures. This approach to composite structure design is much less costly than molded or honeycomb sandwich type composite construction, but may cost slightly more than conventional aluminum construction on the subsystem level. However on the overall program level the weight saving achieved is very cost effective, since the primary objective is to allocate more mass for science payloads.
Fiber-reinforced resin coating for endocrown preparations: a technical report.
Rocca, G T; Rizcalla, N; Krejci, I
2013-01-01
Coronal rehabilitation of endodontically treated posterior teeth is still a controversial issue. Although the use of classical crowns supported by radicular metal posts remains widespread in dentistry, their invasiveness has been largely criticized. New materials and therapeutic options based entirely on adhesion are available nowadays, from direct composite resins to indirect endocrowns. They allow for a more conservative, faster, and less expensive dental treatment. However, the absence of a metal or high-strength ceramic substructure as in full-crown restorations can expose this kind of restoration to a higher risk of irreversible fracture in case of crack propagation. The aim of this case report is to present a technique to reinforce the cavity of an endodontically treated tooth by incorporating a fiber-reinforced composite (FRC) layer into the resin coating of the tooth preparation, before the final impressions of the cavity. This technique allows the use of FRCs in combination with any kind of restorative material for an adhesive overlay/endocrown.
Morris, Mohy G
2010-02-28
With the rapid somatic growth and development in infants, simultaneous accurate measurements of lung volume and airway function are essential. Raised volume rapid thoracoabdominal compression (RTC) is widely used to generate forced expiration from an airway opening pressure of 30 cmH(2)O (V(30)). The (dynamic) functional residual capacity (FRC(dyn)) remains the lung volume most routinely measured. The aim of this study was to develop comprehensive integrated spirometry that included all subdivisions of lung volume at V(30) or total lung capacity (TLC(30)). Measurements were performed on 17 healthy infants aged 8.6-119.7 weeks. A commercial system for multiple-breath nitrogen washout (MBNW) to measure lung volumes and a custom made system to perform RTC were used in unison. A refined automated raised volume RTC and the following two novel single maneuvers with dual volume measurements were performed from V(30) during a brief post-hyperventilation apneic pause: (1) the passive expiratory flow was integrated to produce the inspiratory capacity (IC) and the static (passive) FRC (FRC(st)) was estimated by initiating MBNW after end-passive expiration; (2) RTC was initiated late during passive expiration, flow was integrated to produce the slow vital capacity ((j)SVC) and the residual volume (RV) was measured by initiating MBNW after end-expiration while the jacket (j) was inflated. Intrasubject FRC(dyn) and FRC(st) measurements overlapped (p=0.6420) but neither did with the RV (p<0.0001). Means (95% confidence interval) of FRC(dyn), IC, FRC(st), (j)SVC, RV, forced vital capacity and tidal volume were 21.2 (19.7-22.7), 36.7 (33.0-40.4), 21.2 (19.6-22.8), 40.7 (37.2-44.2), 18.1 (16.6-19.7), 40.7 (37.1-44.2) and 10.2 (9.6-10.7)ml/kg, respectively. Static lung volumes and capacities at V(30) and variables from the best forced expiratory flow-volume curve were dependent on age, body length and weight. In conclusion, we developed a comprehensive physiologically integrated approach for in-depth investigation of lung function at V(30) in infants. Copyright 2009 Elsevier B.V. All rights reserved.
Garoushi, Sufyan K.; Hatem, Marwa; Lassila, Lippo V. J.; Vallittu, Pekka K.
2015-01-01
Abstract Objectives: To determine the marginal microleakage of Class II restorations made with different composite base materials and the static load-bearing capacity of direct composite onlay restorations. Methods: Class II cavities were prepared in 40 extracted molars. They were divided into five groups (n = 8/group) depending on composite base material used (everX Posterior, SDR, Tetric EvoFlow). After Class II restorations were completed, specimens were sectioned mid-sagitally. For each group, sectioned restorations were immersed in dye. Specimens were viewed under a stereo-microscope and the percentage of cavity leakage was calculated. Ten groups of onlay restorations were fabricated (n = 8/group); groups were made with composite base materials (everX Posterior, SDR, Tetric EvoFlow, Gradia Direct LoFlo) and covered by 1 mm layer of conventional (Tetric N-Ceram) or bulk fill (Tetric EvoCeram Bulk Fill) composites. Groups made only from conventional, bulk fill and short fiber composites were used as control. Specimens were statically loaded until fracture. Data were analyzed using ANOVA (p = 0.05). Results: Microleakage of restorations made of plain conventional composite or short fiber composite base material showed statistically (p < 0.05) lower values compared to other groups. ANOVA revealed that onlay restorations made from short fiber-reinforced composite (FRC) as base or plain restoration had statistically significant higher load-bearing capacity (1593 N) (p < 0.05) than other restorations. Conclusion: Restorations combining base of short FRC and surface layer of conventional composite displayed promising performance related to microleakage and load-bearing capacity. PMID:28642894
Yu, Sang-Hui; Lee, Yoon; Oh, Seunghan; Cho, Hye-Won; Oda, Yutaka; Bae, Ji-Myung
2012-01-01
The aim of this study was to evaluate the reinforcing effects of three types of fibers at various concentrations and in different combinations on flexural properties of denture base resin. Glass (GL), polyaromatic polyamide (PA) and ultra-high molecular weight polyethylene (PE) fibers were added to heat-polymerized denture base resin with volume concentrations of 2.6%, 5.3%, and 7.9%, respectively. In addition, hybrid fiber-reinforced composite (FRC) combined with either two or three types of fibers were fabricated. The flexural strength, modulus and toughness of each group were measured with a universal testing machine at a crosshead speed of 5 mm/min. In the single fiber-reinforced composite groups, the 5.3% GL and 7.9% GL had the highest flexural strength and modulus; 5.3% PE was had the highest toughness. Hybrid FRC such as GL/PE, which showed the highest toughness and the flexural strength, was considered to be useful in preventing denture fractures clinically.
Song, Chan-Hong; Choi, Jae-Won; Jeon, Young-Chan; Jeong, Chang-Mo; Lee, So-Hyoun; Kang, Eun-Sook; Yun, Mi-Jung; Huh, Jung-Bo
2018-05-29
The aim of this in-vitro research was to evaluate the microtensile bond strength in the newly introduced PEKK tooth post with various surface treatments and resin cements. A fiberglass tooth post was included in order to compare it with PEKK as a possible post material. The microtensile bond strengths of the fiberglass post (FRC Postec Plus) and the PEKK post (Pekkton ® ) were tested using three kinds of self-adhesive resin cements (G-CEM LinkAce, Multilink Speed, and RelyX U200) and one self-etching resin cement (PANAVIA F2.0). The surface treatments of the fiberglass posts were processed according to the manufacturer's recommendations (F1, application of 37% phosphoric acid etching gel and silanization). For the PEKK post groups, various surface treatments were performed like no surface treatment (P1), sandblasting (P2), silica-coating and silanization (P3), and sandblasting with a composite primer (P4). In the surface treatment, PEKK posts with silica coating and silane treatment (P3) showed a significantly higher microtensile bond strength (mean MPa: 18.09, p < 0.05). The highest microtensile bond strength was shown when the PEKK posts were treated with a silica coating and silane treatment and cemented with RelyX U200 (mean MPa: 22.22). The PEKK posts with surface treatments of silica-coating and silanization or sandblasting displayed superior microtensile bond strengths (mean MPa: 18.09 and 16.25, respectively) compared to the conventional fiberglass posts (mean MPa: 14.93, p < 0.05).
High Dietary Fructose Intake on Cardiovascular Disease Related Parameters in Growing Rats.
Yoo, SooYeon; Ahn, Hyejin; Park, Yoo Kyoung
2016-12-26
The objective of this study was to determine the effects of a high-fructose diet on cardiovascular disease (CVD)-related parameters in growing rats. Three-week-old female Sprague Dawley rats were randomly assigned to four experimental groups; a regular diet group (RD: fed regular diet based on AIN-93G, n = 8), a high-fructose diet group (30Frc: fed regular diet with 30% fructose, n = 8), a high-fat diet group (45Fat: fed regular diet with 45 kcal% fat, n = 8) or a high fructose with high-fat diet group (30Frc + 45Fat, fed diet 30% fructose with 45 kcal% fat, n = 8). After an eight-week treatment period, the body weight, total-fat weight, serum glucose, insulin, lipid profiles and pro-inflammatory cytokines, abdominal aortic wall thickness, and expressions of eNOS and ET-1 mRNA were analyzed. The result showed that total-fat weight was higher in the 30Frc, 45Fat, and 30Frc + 45Fat groups compared to the RD group ( p < 0.05). Serum triglyceride (TG) levels were highest in the 30Frc group than the other groups ( p < 0.05). The abdominal aorta of 30Frc, 45Fat, and 30Frc + 45Fat groups had higher wall thickness than the RD group ( p < 0.05). Abdominal aortic eNOS mRNA level was decreased in 30Frc, 45Fat, and 30Frc + 45Fat groups compared to the RD group ( p < 0.05), and also 45Fat and 30Frc + 45Fat groups had decreased mRNA expression of eNOS compared to the 30Frc group ( p < 0.05). ET-1 mRNA level was higher in 30Frc, 45Fat, and 30Frc + 45Fat groups than the RD group ( p < 0.05). Both high fructose consumption and high fat consumption in growing rats had similar negative effects on CVD-related parameters.
Mangoush, Enas; Säilynoja, Eija; Prinssi, Roosa; Lassila, Lippo; Vallittu, Pekka K.
2017-01-01
Background Fiber reinforced composite (FRC) is a promising class of material that gives clinicians alternative treatment options. There are many FRC products available in the market based on either glass or polyethylene fiber type. The aim of this study was to present a comparison between glass and polyethylene fiber reinforced composites based on available literature review. Material and Methods A thorough literature search, with no limitation, was done up to June 2017. The range of relevant publications was surveyed using PubMed and Google Scholar. From the search results, articles related to our search terms were only considered. An assessment of these articles was done by two individuals in order to include only articles directly compare between glass and polyethylene FRCs. The search terms used were “fiber reinforced dental composites” and “glass and polyethylene fibers in dentistry”. Results The search provided 276 titles. Full-text analysis was performed for 29 articles that met the inclusion criteria. Most were laboratory-based research with various test specimen designs prepared according to ISO standard or with extracted teeth and only three articles were clinical studies. Most of studies (n=23) found superior characteristics of glass FRCs over polyethylene FRCs. Conclusions Significant reinforcement differences between commercial glass and polyethylene fiber reinforced composites were found. Key words:Fiber reinforced composite, glass fiber, polyethylene fiber. PMID:29410756
Fiber Reinforced Concrete (FRC) for High Rise Construction: Case Studies
NASA Astrophysics Data System (ADS)
Gharehbaghi, Koorosh; Chenery, Rhea
2017-12-01
Due to its material element, Fiber Reinforced Concrete (FRC) could be stronger than traditional Concrete. This is due to FRC internal material compounds and elements. Furthermore, FRC can also significantly improve flexural strength when compared to traditional Concrete. This improvement in flexural strength can be varied depending on the actual fibers used. Although not new, FRC is gradually gaining popularity in the construction industry, in particular for high rise structures. This is due to its flexural strength, especially for high seismic zones, as it will provide a better solution then reinforced Concrete. The main aim of this paper is to investigate the structural importance of FRC for the high rise construction. Although there has been numerous studies and literature in justifying the FRC for general construction; this paper will consider its use specifically for high rise construction. Moreover, this paper will closely investigate eight case studies from Australian and United States as a part of the FRC validation for high rise construction. In doing so, this paper will examine their Structural Health Monitoring (SHM) to determine their overall structural performance.
Morris, Mohy G.
2011-01-01
Summary The dynamic functional residual capacity (FRCdyn), the lung volume most routinely measured in infants, is an unreliable volume landmark. In addition to the FRCdyn, we measured the (passive) static FRC (FRCst) by inducing a brief post-hyperventilation apnea (PHA) in 33 healthy infants aged 7.4–127.2 weeks. A commercial system for nitrogen (N2) washout to measure FRC, and a custom made system to monitor and record flow and airwayopening pressure signals in real-time were used in unison. Infants were manually hyperventilated to induce a PHA. After the last passive expiration, FRCst was estimated by measuring the volume of N2 expired after end-passive expiratory switching of the inspired gas from room air to 100% oxygen during the post-expiratory apneic pause. Repeatable intrasubject FRCst and FRCdyn measurements overlapped in most infants including the younger ones (P = 0.2839). Mean (95% confidence interval [CI]) FRCst was 21.1 (20.0–22.3), and error-corrected FRCdyn was 21.4 (20.4–22.4) ml/kg. Mean (washout time [t]) tFRCst was longer than tFRCdyn 60 sec (95% CI 55–65) versus 47 sec (95% CI 43–51) (P<0.0001). The FRC and washout time were dependent on body length, weight and age. We conclude that the FRCst is not different from the FRCdyn in infants. The FRCst is a reliable volume landmark because the PHA stabilizes the end-expiratory level by potentially abolishing the sedated infant’s breathing strategies. The FRCst lacks potential sources of errors and disadvantages associated with measuring the FRCdyn. The findings cast significant doubt on the traditional physiology of air trapping in healthy infants’ lungs. PMID:19499588
Mitov, Gergo; Dörr, Michael; Nothdurft, Frank P; Draenert, Florian; Pospiech, Peter R
2015-06-01
The aim of the present study was to evaluate the trend of dental practitioners in the federal state of Saarland in Germany in regard to restoring endodontically treated teeth using a Web-based survey. An interactive Web-based survey instrument was developed, including seven clinical scenarios, presented by photographs of natural incisor and premolar with different types of cavities. Following a decision tree adapted to the clinical treatment, questions on different aspects of the post-endodontic treatment were asked. All 615 members of the Saarland Dental Association (SDA) were asked to participate in the survey. A total of 33 % completed the survey. The majority of the participants believed in the reinforcement effect of the ferrule design, as well as the post placement. The vast majority of the responding practitioners (92 %) adapted their treatment strategies to a high extent to the destruction degree of the endodontically treated tooth. Fiber-reinforced composite (FRC) posts are the most popular prefabricated post type, regardless of the cavity size and tooth localization. Significant differences between the dentists according to the degree of experience were detected only for the use of glass-ionomer cements as core buildup material. The predominant post-endodontic treatment strategies of German dental practitioners are only partly in agreement with the current literature. There is a clear trend toward the increasing use of metal-free post and core materials. Although the participants showed a general adoption of modern materials and techniques, different patterns of post-endodontic treatment were revealed that were not consistent with approaches supported by the literature.
Fibre reinforced concrete exposed to elevated temperature
NASA Astrophysics Data System (ADS)
Novák, J.; Kohoutková, A.
2017-09-01
Although concrete when subject to fire performs very well, its behaviour and properties change dramatically under high temperature due to damaged microstructure and mesostructure. As fibre reinforced concrete (FRC) represents a complex material composed of various components with different response to high temperature, to determine its behaviour and mechanical properties in fire is a demanding task. The presented paper provides a summary of findings on the fire response of fibre FRC. Namely, the information on steel fibre reinforced concrete (SFRC), synthetic fibre reinforced concrete and hybrid (steel + synthetic) fibre reinforced concrete have been gathered from various contributions published up to date. The mechanical properties including the melting point and ignition point of fibres affect significantly the properties of concrete composites with addition of fibres. The combination of steel and synthetic fibres represents a promising alternative how to ensure good toughness of a concrete composite before heating and improve its residual mechanical behaviour and spalling resistance as well as the ductility after heating. While synthetic fibres increase concrete spalling resistance, steel fibres in a concrete mix leads to an improvement in both mechanical properties and resistance to heating effects.
Crawshaw, Jessica R; Hooper, Stuart B; Te Pas, Arjan B; Allison, Beth A; Wallace, Megan J; Kerr, Lauren T; Lewis, Robert A; Morley, Colin J; Leong, Andrew F; Kitchen, Marcus J
2016-09-01
Antenatal glucocorticoids, exogenous surfactant, and positive end-expiratory pressure (PEEP) ventilation are commonly provided to preterm infants to enhance respiratory function after birth. It is unclear how these treatments interact to improve the transition to air-breathing at birth. We investigated the relative contribution of antenatal betamethasone, prophylactic surfactant, and PEEP (3 cmH 2 O) on functional residual capacity (FRC) and dynamic lung compliance (C DL ) in preterm (28 day GA) rabbit kittens at birth. Kittens were delivered by cesarean section and mechanically ventilated. FRC was calculated from X-ray images, and C DL was measured using plethysmography. Without betamethasone, PEEP increased FRC recruitment and C DL Surfactant did not further increase FRC, but significantly increased C DL Betamethasone abolished the benefit of PEEP on FRC, but surfactant counteracted this effect of betamethasone. These findings indicate that low PEEP levels are insufficient to establish FRC at birth following betamethasone treatment. However, surfactant reversed the effect of betamethasone and when combined, these two treatments enhanced FRC recruitment irrespective of PEEP level. Copyright © 2016 the American Physiological Society.
Schibler, Andreas; Hammer, Jürg; Isler, Ruedi; Buess, Christian; Newth, Christopher J L
2004-01-01
Measurement of functional residual capacity (FRC) during mechanical ventilation is important to standardise respiratory system compliance and adjust the ventilator settings to optimise lung recruitment. In the present study we compared three methods to measure FRC. The bias flow nitrogen washout technique (FRC(N2MC)), the multiple breath nitrogen washout (FRC(MBNW)) and the multiple breath sulphur-hexafluoride washout using the molar mass signal of an ultrasonic flow meter (FRC(MBSF6)) were compared in six adult monkeys after endotracheal intubation and during spontaneous breathing and mechanical ventilation at three different positive end-expiratory pressure (PEEP) levels of 0, 5 and 10 cmH2O. Animal research laboratory. We found good agreement between all three methods and they all accurately measured changes in FRC when PEEP was increased. The coefficients of variance of the three measurement techniques were in the same range (1.3-9.2%). The measurement of the tracer gas concentration with the molar mass signal of the ultrasonic flow meter provides a good and simple alternative to respiratory mass spectrometer for FRC measurements in ventilated subjects.
Magnetic Diagnostics on the Magnetized Shock Experiment (MSX)
NASA Astrophysics Data System (ADS)
Hutchinson, T. M.; Weber, T. E.; Boguski, J. C.; Intrator, T. P.; Smith, R. J.; Dunn, J. P.
2013-10-01
The Magnetized Shock Experiment (MSX) at Los Alamos National Laboratory was built to investigate the physics of high-Alfvénic, supercritical, magnetized shocks through the acceleration and subsequent stagnation of a Field Reversed Configuration (FRC) plasmoid against a magnetic mirror and/or plasma target. An array of high-bandwidth, multi-axis, robust, internal magnetic probes has been constructed to characterize flux compression ratios, instability formation, and turbulent macro-scale features of the post-shock plasma. The mirror magnet is mounted on a linear translation stage, providing a capability to axially move the shock layer through the probe field of view. An independent, external probe array also provides conventional information on the FRC shape, velocity, and total pressure during the formation and acceleration phases. Probe design, characterization, configuration, and initial results are presented. This work is supported by the DOE OFES and NNSA under LANS contract DE-AC52-06NA25369. LA-UR-13-25189.
Effects of umeclidinium/vilanterol on exercise endurance in COPD: a randomised study.
Riley, John H; Kalberg, Chris J; Donald, Alison; Lipson, David A; Shoaib, Muhammad; Tombs, Lee
2018-01-01
This multicentre, randomised, double-blind, placebo-controlled, two-period crossover study assessed the effect of umeclidinium/vilanterol (UMEC/VI) on exercise capacity in patients with chronic obstructive pulmonary disease (COPD) using the endurance shuttle walk test (ESWT). Patients were randomised 1:1 to one of two treatment sequences: 1) UMEC/VI 62.5/25 µg followed by placebo or 2) placebo followed by UMEC/VI 62.5/25 µg. Each treatment was taken once daily for 12 weeks. The primary end-point was 3-h post-dose exercise endurance time (EET) at week 12. Secondary end-points included trough forced expiratory volume in 1 s (FEV 1 ) and 3-h post-dose functional residual capacity (FRC), both at week 12. COPD Assessment Test (CAT) score at week 12 was also assessed. UMEC/VI treatment did not result in a statistically significant improvement in EET change from baseline at week 12 versus placebo (p=0.790). However, improvements were observed in trough FEV 1 (206 mL, 95% CI 167-246), 3-h post-dose FRC (-346 mL, 95% CI -487 to -204) and CAT score (-1.07 units, 95% CI -2.09 to -0.05) versus placebo at week 12. UMEC/VI did not result in improvements in EET at week 12 versus placebo, despite improvements in measures of lung function, hyperinflation and health status.
Nagas, Emre; Uyanik, Ozgur; Altundasar, Emre; Durmaz, Veli; Cehreli, Zafer C; Vallittu, Pekka K; Lassila, Lippo V J
2010-06-01
This study investigated and compared the root reinforcement potential of 3 different intraorifice barriers (mineral trioxide aggregate [MTA], resin-modified glass ionomer cement [Vitremer], and fiber-reinforced composite [FRC]) placed over root canals obturated with gutta-percha or Resilon. Crowns of 80 extracted human mandibular premolars were sectioned off to obtain 14-mm-long root specimens. After preparation of root canals with nickel-titanium rotary files, the roots were obturated with either the Resilon/Epiphany system or gutta-percha + AH Plus sealer. In both obturation groups, specimens were further subgrouped with respect to the intraorifice barrier material placed after removal of 3-mm coronal portion of the root fillings: (1) MTA, (2) Vitremer, and (3) FRC. The specimens were loaded vertically at 1 mm/min crosshead speed until vertical root fracture occurred. Results were evaluated statistically with two-way analysis of variance and Tukey tests. Fracture resistance of roots was significantly affected by the type of intraorifice barrier (P < .05), but not by the type of obturation system used (P > .05). The use of Vitremer and FRC significantly improved the fracture resistance, whereas MTA did not exhibit any reinforcing effect as an intraorifice barrier. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Braun, Alexandra C; Ilko, David; Merget, Benjamin; Gieseler, Henning; Germershaus, Oliver; Holzgrabe, Ulrike; Meinel, Lorenz
2015-08-01
This manuscript addresses the capability of compendial methods in controlling polysorbate 80 (PS80) functionality. Based on the analysis of sixteen batches, functionality related characteristics (FRC) including critical micelle concentration (CMC), cloud point, hydrophilic-lipophilic balance (HLB) value and micelle molecular weight were correlated to chemical composition including fatty acids before and after hydrolysis, content of non-esterified polyethylene glycols and sorbitan polyethoxylates, sorbitan- and isosorbide polyethoxylate fatty acid mono- and diesters, polyoxyethylene diesters, and peroxide values. Batches from some suppliers had a high variability in functionality related characteristic (FRC), questioning the ability of the current monograph in controlling these. Interestingly, the combined use of the input parameters oleic acid content and peroxide value - both of which being monographed methods - resulted in a model adequately predicting CMC. Confining the batches to those complying with specifications for peroxide value proved oleic acid content alone as being predictive for CMC. Similarly, a four parameter model based on chemical analyses alone was instrumental in predicting the molecular weight of PS80 micelles. Improved models based on analytical outcome from fingerprint analyses are also presented. A road map controlling PS80 batches with respect to FRC and based on chemical analyses alone is provided for the formulator. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
T., Ii; Inomoto, M.; Gi, K.; Umezawa, T.; Ito, T.; Kadowaki, K.; Kaminou, Y.; Ono, Y.
2013-07-01
A low-energy, high-current neutral beam injection (NBI) was applied to an oblate field-reversed configuration (FRC) for the first time. The NB fast ions reduce growth rates of low-n modes dangerous for the oblate FRC, extending the FRC lifetime by a factor of 1.2. The reduced loss power of 5 MW is much higher than the NBI power of 0.5 MW, indicating that the NBI not only heats the FRC plasma but also improves its stability and transport properties. The NBI also maintains higher pressure and current density profiles of the FRC, improving its flux and energy decay times by a factor of 2.
Gyrokinetic simulation of driftwave instability in field-reversed configuration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fulton, D. P., E-mail: dfulton@trialphaenergy.com; University of California, Irvine, California 92697; Lau, C. K.
2016-05-15
Following the recent remarkable progress in magnetohydrodynamic (MHD) stability control in the C-2U advanced beam driven field-reversed configuration (FRC), turbulent transport has become one of the foremost obstacles on the path towards an FRC-based fusion reactor. Significant effort has been made to expand kinetic simulation capabilities in FRC magnetic geometry. The recently upgraded Gyrokinetic Toroidal Code (GTC) now accommodates realistic magnetic geometry from the C-2U experiment at Tri Alpha Energy, Inc. and is optimized to efficiently handle the FRC's magnetic field line orientation. Initial electrostatic GTC simulations find that ion-scale instabilities are linearly stable in the FRC core for realisticmore » pressure gradient drives. Estimated instability thresholds from linear GTC simulations are qualitatively consistent with critical gradients determined from experimental Doppler backscattering fluctuation data, which also find ion scale modes to be depressed in the FRC core. Beyond GTC, A New Code (ANC) has been developed to accurately resolve the magnetic field separatrix and address the interaction between the core and scrape-off layer regions, which ultimately determines global plasma confinement in the FRC. The current status of ANC and future development targets are discussed.« less
Gyrokinetic simulation of driftwave instability in field-reversed configuration
NASA Astrophysics Data System (ADS)
Fulton, D. P.; Lau, C. K.; Schmitz, L.; Holod, I.; Lin, Z.; Tajima, T.; Binderbauer, M. W.
2016-05-01
Following the recent remarkable progress in magnetohydrodynamic (MHD) stability control in the C-2U advanced beam driven field-reversed configuration (FRC), turbulent transport has become one of the foremost obstacles on the path towards an FRC-based fusion reactor. Significant effort has been made to expand kinetic simulation capabilities in FRC magnetic geometry. The recently upgraded Gyrokinetic Toroidal Code (GTC) now accommodates realistic magnetic geometry from the C-2U experiment at Tri Alpha Energy, Inc. and is optimized to efficiently handle the FRC's magnetic field line orientation. Initial electrostatic GTC simulations find that ion-scale instabilities are linearly stable in the FRC core for realistic pressure gradient drives. Estimated instability thresholds from linear GTC simulations are qualitatively consistent with critical gradients determined from experimental Doppler backscattering fluctuation data, which also find ion scale modes to be depressed in the FRC core. Beyond GTC, A New Code (ANC) has been developed to accurately resolve the magnetic field separatrix and address the interaction between the core and scrape-off layer regions, which ultimately determines global plasma confinement in the FRC. The current status of ANC and future development targets are discussed.
Gyrokinetic particle simulation of a field reversed configuration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fulton, D. P., E-mail: dfulton@uci.edu; Lau, C. K.; Holod, I.
2016-01-15
Gyrokinetic particle simulation of the field-reversed configuration (FRC) has been developed using the gyrokinetic toroidal code (GTC). The magnetohydrodynamic equilibrium is mapped from cylindrical coordinates to Boozer coordinates for the FRC core and scrape-off layer (SOL), respectively. A field-aligned mesh is constructed for solving self-consistent electric fields using a semi-spectral solver in a partial torus FRC geometry. This new simulation capability has been successfully verified and driftwave instability in the FRC has been studied using the gyrokinetic simulation for the first time. Initial GTC simulations find that in the FRC core, the ion-scale driftwave is stabilized by the large ionmore » gyroradius. In the SOL, the driftwave is unstable on both ion and electron scales.« less
Zeng, Ming; Paiardini, Mirko; Engram, Jessica C; Beilman, Greg J; Chipman, Jeffrey G; Schacker, Timothy W; Silvestri, Guido; Haase, Ashley T
2012-08-30
Loss of the fibroblastic reticular cell (FRC) network in lymphoid tissues during HIV-1 infection has been shown to impair the survival of naive T cells and limit immune reconstitution after antiretroviral therapy. What causes this FRC loss is unknown. Because FRC loss correlates with loss of both naive CD4 and CD8 T-cell subsets and decreased lymphotoxin-β, a key factor for maintenance of FRC network, we hypothesized that loss of naive T cells is responsible for loss of the FRC network. To test this hypothesis, we assessed the consequences of antibody-mediated depletion of CD4 and CD8 T cells in rhesus macaques and sooty mangabeys. We found that only CD4 T-cell depletion resulted in FRC loss in both species and that this loss was caused by decreased lymphotoxin-β mainly produced by the CD4 T cells. We further found the same dependence of the FRC network on CD4 T cells in HIV-1-infected patients before and after antiretroviral therapy and in other immunodeficiency conditions, such as CD4 depletion in cancer patients induced by chemotherapy and irradiation. CD4 T cells thus play a central role in the maintenance of lymphoid tissue structure necessary for their own homeostasis and reconstitution.
Effects of umeclidinium/vilanterol on exercise endurance in COPD: a randomised study
Kalberg, Chris J.; Donald, Alison; Lipson, David A.; Shoaib, Muhammad; Tombs, Lee
2018-01-01
This multicentre, randomised, double-blind, placebo-controlled, two-period crossover study assessed the effect of umeclidinium/vilanterol (UMEC/VI) on exercise capacity in patients with chronic obstructive pulmonary disease (COPD) using the endurance shuttle walk test (ESWT). Patients were randomised 1:1 to one of two treatment sequences: 1) UMEC/VI 62.5/25 µg followed by placebo or 2) placebo followed by UMEC/VI 62.5/25 µg. Each treatment was taken once daily for 12 weeks. The primary end-point was 3-h post-dose exercise endurance time (EET) at week 12. Secondary end-points included trough forced expiratory volume in 1 s (FEV1) and 3-h post-dose functional residual capacity (FRC), both at week 12. COPD Assessment Test (CAT) score at week 12 was also assessed. UMEC/VI treatment did not result in a statistically significant improvement in EET change from baseline at week 12 versus placebo (p=0.790). However, improvements were observed in trough FEV1 (206 mL, 95% CI 167–246), 3-h post-dose FRC (−346 mL, 95% CI −487 to −204) and CAT score (−1.07 units, 95% CI −2.09 to −0.05) versus placebo at week 12. UMEC/VI did not result in improvements in EET at week 12 versus placebo, despite improvements in measures of lung function, hyperinflation and health status. PMID:29322050
Yamada, Masaaki
2016-01-01
This study briefly reviews a compact toroid reactor concept that addresses critical issues for forming, stabilizing and sustaining a field reversed configuration (FRC) with the use of plasma merging, plasma shaping, conducting shells, neutral beam injection (NBI). In this concept, an FRC plasma is generated by the merging of counter-helicity spheromaks produced by inductive discharges and sustained by the use of neutral beam injection (NBI). Plasma shaping, conducting shells, and the NBI would provide stabilization to global MHD modes. Although a specific FRC reactor design is outside the scope of the present paper, an example of a promising FRC reactormore » program is summarized based on the previously developed SPIRIT (Self-organized Plasmas by Induction, Reconnection and Injection Techniques) concept in order to connect this concept to the recently achieved the High Performance FRC plasmas obtained by Tri Alpha Energy [Binderbauer et al, Phys. Plasmas 22,056110, (2015)]. This paper includes a brief summary of the previous concept paper by M. Yamada et al, Plasma Fusion Res. 2, 004 (2007) and the recent experimental results from MRX.« less
Simulation of the target creation through FRC merging for a magneto-inertial fusion concept
NASA Astrophysics Data System (ADS)
Li, Chenguang; Yang, Xianjun
2017-04-01
A two-dimensional magnetohydrodynamics model has been used to simulate the target creation process in a magneto-inertial fusion concept named Magnetized Plasma Fusion Reactor (MPFR) [C. Li and X. Yang, Phys. Plasmas 23, 102702 (2016)], where the target plasma created through Field reversed configuration (FRC) merging was compressed by an imploding liner driven by the pulsed-power driver. In the scheme, two initial FRCs (Field reversed configurations) are translated into the region where FRC merging occurs, bringing out the target plasma ready for compression. The simulations cover the three stages of the target creation process: formation, translation, and merging. The factors affecting the achieved target are analyzed numerically. The magnetic field gradient produced by the conical coils is found to determine how fast the FRC is accelerated to peak velocity and the collision merging occurs. Moreover, it is demonstrated that FRC merging can be realized by real coils with gaps showing nearly identical performance, and the optimized target by FRC merging shows larger internal energy and retained flux, which is more suitable for the MPFR concept.
NASA Astrophysics Data System (ADS)
Yamada, Masaaki
2016-03-01
This paper briefly reviews a compact toroid reactor concept that addresses critical issues for forming, stabilizing and sustaining a field reversed configuration (FRC) with the use of plasma merging, plasma shaping, conducting shells, neutral beam injection (NBI). In this concept, an FRC plasma is generated by the merging of counter-helicity spheromaks produced by inductive discharges and sustained by the use of neutral beam injection (NBI). Plasma shaping, conducting shells, and the NBI would provide stabilization to global MHD modes. Although a specific FRC reactor design is outside the scope of the present paper, an example of a promising FRC reactor program is summarized based on the previously developed SPIRIT (Self-organized Plasmas by Induction, Reconnection and Injection Techniques) concept in order to connect this concept to the recently achieved the High Performance FRC plasmas obtained by Tri Alpha Energy [Binderbauer et al, Phys. Plasmas 22,056110, (2015)]. This paper includes a brief summary of the previous concept paper by M. Yamada et al, Plasma Fusion Res. 2, 004 (2007) and the recent experimental results from MRX.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamada, Masaaki
2016-03-25
This paper briefly reviews a compact toroid reactor concept that addresses critical issues for forming, stabilizing and sustaining a field reversed configuration (FRC) with the use of plasma merging, plasma shaping, conducting shells, neutral beam injection (NBI). In this concept, an FRC plasma is generated by the merging of counter-helicity spheromaks produced by inductive discharges and sustained by the use of neutral beam injection (NBI). Plasma shaping, conducting shells, and the NBI would provide stabilization to global MHD modes. Although a specific FRC reactor design is outside the scope of the present paper, an example of a promising FRC reactormore » program is summarized based on the previously developed SPIRIT (Self-organized Plasmas by Induction, Reconnection and Injection Techniques) concept in order to connect this concept to the recently achieved the High Performance FRC plasmas obtained by Tri Alpha Energy [Binderbauer et al, Phys. Plasmas 22,056110, (2015)]. This paper includes a brief summary of the previous concept paper by M. Yamada et al, Plasma Fusion Res. 2, 004 (2007) and the recent experimental results from MRX.« less
Hydrostatic weighing at residual volume and functional residual capacity.
Thomas, T R; Etheridge, G L
1980-07-01
Hydrostatic weighing (HW) was performed at both residual volume (RV) and functional residual capacity (FRC) to determine if underwater weighing at different lung volumes affected the measurement of body density. Subjects were 43 males, 18-25 yr. Subjects were submerged in the prone position, and the lung volume was measured by helium dilution at the time of the underwater weighing. Underwater weight was first assessed at FRC followed by assessment at RV. Changes in lung volume were accurately reflected in the underwater weight. Body density (D) was not different with the use of the FRC (mean D = 1.0778) or RV (mean D = 1.0781) data. Percent fat values for the FRC and RV data were 9.3 +/- 5.4 and 9.2 +/- 5.1%, respectively, and were not statistically different. The results indicate that the difference between percent fat determinations by HW in the prone position at FRC and RV is negligible. Because measurement of underwater weight at FRC is more comfortable for the subject, this may be the method of choice when the lung volume can be measured during the underwater weighing.
Wauer, Juliane; Leier, Tim U; Henschen, Matthias; Wauer, Roland R; Schmalisch, Gerd
2003-05-01
Ultrasonic transit-time airflow meters (UFM) allow simultaneous measurements of volume flow V'(t) and molar mass MM(t) of the breathing gas in the mainstream. Consequently, by using a suitable tracer gas the functional residual capacity (FRC) of the lungs can be measured by a gas wash-in/wash-out technique. The aim of this study was to investigate the in vitro accuracy of a multiple-breath wash-in/wash-out technique for FRC measurements using 4% sulphur hexafluoride (SF6) in air. V'(t) and MM(t) were measured with a Spiroson SCIENTIFIC flowmeter (ECO Medics, CH) with 1.3 ml dead space. Linearity of airflow and MM were tested using different tidal volumes (V(T)) and breathing gases with different O2 and SF6 concentrations. To determine the accuracy of FRC measurements SF6 wash-in and wash-out curves from four mechanical lung models (FRC of 22, 53, 102 and 153 ml) were evaluated by the Spiroson. For each model five measurements were performed with a physiological V(T)/FRC ratio of 0.3 and constant respiratory rate of 30 min(-1). The error of measured V(T) (range 4-60 ml) was <2.5%. There was a strong correlation between the measured and calculated MM of different breathing gases (r = 0.989), and the measuring accuracy was better than 1%. The measured FRC of the four models were 20.3, 49.7, 104.3 and 153.4 ml with a coefficient of variation of 16.5%, 4.5%, 4.9% and 3%. Accordingly, for FRC <100 ml the in vitro accuracy was better than 8% and for FRC >100 ml better than 2.5%. The determination of FRC by MM measurements using the UFM is a simple and cost-effective alternative to conventionally used gas analysers with an acceptable accuracy for many clinical purposes.
Mechanical properties and material characterization of polysialate structural composites
NASA Astrophysics Data System (ADS)
Foden, Andrew James
One of the major concerns in using Fiber Reinforced Composites in applications that are subjected to fire is their resistance to high temperature. Some of the fabrics used in FRC, such as carbon, are fire resistant. However, almost all the resins used cannot withstand temperatures higher than 200°C. This dissertation deals with the development and use of a potassium aluminosilicate (GEOPOLYMER) resin that is inorganic and can sustain more than 1000°C. The results presented include the mechanical properties of the unreinforced polysialate matrix in tension, flexure, and compression as well as the strain capacities and surface energy. The mechanical properties of the matrix reinforced with several different fabrics were obtained in flexure, tension, compression and shear. The strength and stiffness of the composite was evaluated for each loading condition. Tests were conducted on unexposed samples as well as samples exposed to temperatures from 200 to 1000°C. Fatigue properties were determined using flexural loading. A study of the effect of several processing variables on the properties of the composite was undertaken to determine the optimum procedure for manufacturing composite plates. The processing variables studied were the curing temperature and pressure, and the post cure drying time required to remove any residual water. The optimum manufacturing conditions were determined using the void content, density, fiber volume fraction, and flexural strength. Analytical models are presented based on both micro and macro mechanical analysis of the composite. Classic laminate theory is used to evaluate the state of the composite as it is being loaded to determine the failure mechanisms. Several failure criteria theories are considered. The analysis is then used to explain the mechanical behavior of the composite that was observed during the experimental study.
Zeng, Ming; Paiardini, Mirko; Engram, Jessica C.; Beilman, Greg J.; Chipman, Jeffrey G.; Schacker, Timothy W.; Silvestri, Guido
2012-01-01
Loss of the fibroblastic reticular cell (FRC) network in lymphoid tissues during HIV-1 infection has been shown to impair the survival of naive T cells and limit immune reconstitution after antiretroviral therapy. What causes this FRC loss is unknown. Because FRC loss correlates with loss of both naive CD4 and CD8 T-cell subsets and decreased lymphotoxin-β, a key factor for maintenance of FRC network, we hypothesized that loss of naive T cells is responsible for loss of the FRC network. To test this hypothesis, we assessed the consequences of antibody-mediated depletion of CD4 and CD8 T cells in rhesus macaques and sooty mangabeys. We found that only CD4 T-cell depletion resulted in FRC loss in both species and that this loss was caused by decreased lymphotoxin-β mainly produced by the CD4 T cells. We further found the same dependence of the FRC network on CD4 T cells in HIV-1–infected patients before and after antiretroviral therapy and in other immunodeficiency conditions, such as CD4 depletion in cancer patients induced by chemotherapy and irradiation. CD4 T cells thus play a central role in the maintenance of lymphoid tissue structure necessary for their own homeostasis and reconstitution. PMID:22613799
NASA Astrophysics Data System (ADS)
Intrator, T.; Zhang, S. Y.; Degnan, J. H.; Furno, I.; Grabowski, C.; Hsu, S. C.; Ruden, E. L.; Sanchez, P. G.; Taccetti, J. M.; Tuszewski, M.; Waganaar, W. J.; Wurden, G. A.
2004-05-01
Magnetized target fusion (MTF) is a potentially low cost path to fusion, intermediate in plasma regime between magnetic and inertial fusion energy. It requires compression of a magnetized target plasma and consequent heating to fusion relevant conditions inside a converging flux conserver. To demonstrate the physics basis for MTF, a field reversed configuration (FRC) target plasma has been chosen that will ultimately be compressed within an imploding metal liner. The required FRC will need large density, and this regime is being explored by the FRX-L (FRC-Liner) experiment. All theta pinch formed FRCs have some shock heating during formation, but FRX-L depends further on large ohmic heating from magnetic flux annihilation to heat the high density (2-5×1022m-3), plasma to a temperature of Te+Ti≈500 eV. At the field null, anomalous resistivity is typically invoked to characterize the resistive like flux dissipation process. The first resistivity estimate for a high density collisional FRC is shown here. The flux dissipation process is both a key issue for MTF and an important underlying physics question.
Overview of C-2U FRC Experimental Program and Plans for C-2W
NASA Astrophysics Data System (ADS)
Gota, H.; Binderbauer, M. W.; Tajima, T.; Putvinski, S.; Tuszewski, M.; Dettrick, S.; Korepanov, S.; Smirnov, A.; Thompson, M. C.; Yang, X.; Cappello, M.; Ivanov, A. A.; TAE Team
2016-10-01
Tri Alpha Energy's experimental program has been focused on a demonstration of reliable field-reversed configuration (FRC) formation and sustainment, driven by fast ions via high-power neutral-beam (NB) injection. The world's largest compact-toroid experimental devices, C-2 and C-2U, have successfully produced a well-stabilized, sustainable FRC plasma state with NB injection (input power, PNB 10 + MW; 15 keV hydrogen) and end-on coaxial plasma guns. Remarkable improvements in confinement and stability of FRC plasmas have led to further improved fast-ion build up; thereby, an advanced beam-driven FRC state has been produced and sustained for up to 5 + ms (longer than all characteristic system time scales), only limited by hardware and electric supply constraints such as NB and plasma-gun power supplies. To further improve the FRC performance the C-2U device is being replaced by C-2W featuring higher injected NB power, longer pulse duration as well as enhanced edge-biasing systems and substantially upgraded divertors. Main C-2U experimental results and key features of C-2W will be presented. Tri Alpha Energy, Inc.
The FAST (FRC Acceleration Space Thruster) Experiment
NASA Technical Reports Server (NTRS)
Martin, Adam; Eskridge, R.; Lee, M.; Richeson, J.; Smith, J.; Thio, Y. C. F.; Slough, J.; Rodgers, Stephen L. (Technical Monitor)
2001-01-01
The Field Reverse Configuration (FRC) is a magnetized plasmoid that has been developed for use in magnetic confinement fusion. Several of its properties suggest that it may also be useful as a thruster for in-space propulsion. The FRC is a compact toroid that has only poloidal field, and is characterized by a high plasma beta = (P)/(B (sup 2) /2Mu0), the ratio of plasma pressure to magnetic field pressure, so that it makes efficient use of magnetic field to confine a plasma. In an FRC thruster, plasmoids would be repetitively formed and accelerated to high velocity; velocities of = 250 km/s (Isp = 25,000s) have already been achieved in fusion experiments. The FRC is inductively formed and accelerated, and so is not subject to the problem of electrode erosion. As the plasmoid may be accelerated over an extended length, it can in principle be made very efficient. And the achievable jet powers should be scalable to the MW range. A 10 kW thruster experiment - FAST (FRC Acceleration Space Thruster) has just started at the Marshall Space Flight Center. The design of FAST and the status of construction and operation will be presented.
Shariff, Jaffer A; Ahluwalia, Kavita P; Papapanou, Panos N
2017-03-01
Recreational use of cannabis, following its legalization in some countries, poses emergent oral and periodontal health concerns. The objective of this study is to examine the relationship between frequent recreational cannabis (FRC) (marijuana and hashish) use and periodontitis prevalence among adults in the United States. Data from the National Health and Nutrition Examination Survey (NHANES) 2011 to 2012 were analyzed. Primary outcome (periodontitis) was defined using the Centers for Disease Control and Prevention/American Academy of Periodontology classification as well as continuous measurements of probing depth (PD) and clinical attachment loss (AL). Exposure of interest was self-reported cannabis use, defined as "FRC use" versus "non-FRC use." Bivariate and multivariable regression models were performed using the entire analytical sample (model 1) as well as those who had never used tobacco (never-users) (model 2). Of 1,938 participants with available cannabis use data and essential covariates, 26.8% were FRC users. Mean number of sites per participant with PD ≥4, ≥6, and ≥8 mm and AL ≥3, ≥5, and ≥8 mm was significantly higher among FRC users than among non-FRC users (mean difference in number of PD sites: 6.9, 5.6, and 5.6; P <0.05; mean difference in number of AL sites: 12.7, 7.6, and 5.6; P <0.05). Average AL was higher among FRC users than among non-FRC users (1.8 versus 1.6 mm; P = 0.004). Bivariate analysis revealed positive (harmful) association between FRC use and severe periodontitis in the entire sample (odds ratio [OR]: 1.7, 95% confidence interval [CI]: 1.3 to 2.4; P = 0.002) as well as in never-smokers (OR: 2.0, 95% CI: 1.2 to 3.5; P = 0.01). This association was retained in multivariable models adjusted for demographics (age, sex, race/ethnicity, and income level), alcohol and tobacco use, diabetes mellitus, and past periodontal treatment (model 1: adjusted OR [aOR]: 1.4, 95% CI: 1.1 to 1.9; P = 0.07; model 2: aOR: 1.9, 95% CI: 1.1 to 3.2; P = 0.03). FRC use is associated with deeper PDs, more clinical AL, and higher odds of having severe periodontitis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yambe, Kiyoyuki; Inomoto, Michiaki; Okada, Shigefumi
The effects of an internal structure on the equilibrium of a field-reversed configuration (FRC) plasma sustained by rotating magnetic field is investigated by using detailed electrostatic probe measurements in the FRC Injection Experiment apparatus [S. Okada, et al., Nucl. Fusion. 45, 1094 (2005)]. An internal structure installed axially on the geometrical axis, which simulates Ohmic transformer or external toroidal field coils on the FRC device, brings about substantial changes in plasma density profile. The internal structure generates steep density-gradients not only on the inner side but on the outer side of the torus. The radial electric field is observed tomore » sustain the ion thermal pressure-gradient in the FRC without the internal structure; however, the radial electric field is not sufficient to sustain the increased ion thermal pressure-gradient in the FRC with the internal structure. Spontaneously driven azimuthal ion flow will be accountable for the imbalance of the radial pressure which is modified by the internal structure.« less
CREATION OF MUSIC WITH FIBER REINFORCED CONCRETE
NASA Astrophysics Data System (ADS)
Kato, Hayato; Takeuchi, Masaki; Ogura, Naoyuki; Kitahara, Yukiko; Okamoto, Takahisa
This research focuses on the Fiber Reinforcement Concrete(FRC) and its performance on musical tones. Thepossibility of future musical instruments made of this concrete is discussed. Recently, the technical properties of FRC had been improved and the different production styles, such as unit weight of binding material and volume of fiber in the structure, hardly affects the results of the acoustics. However, the board thickness in the FRC instruments is directly related with the variety of musical tone. The FRC musical effects were compared with those produced with wood on wind instruments. The sounds were compared with those produced with woodwind instruments. The sound pressure level was affected by the material and it becomes remarkably notorious in the high frequency levels. These differences had great influence on the spectrum analysis of the tone in the wind instruments and the sensory test. The results from the sensory test show dominant performances of brightness, beauty and power in the FRC instruments compared with those made of wood.
Zhang, Yanqiu; Zhang, Daning; Zhang, Mianzhi
2012-12-01
To evaluate inhibition effect and mechanism of compound ethanol extracts from Wuweizi (Fructus Schisandrae Chinensis), Chuanxiong (Rhizoma Chuanxiong) and Muli (Cocha Ostreae) (FRC) on glomerular and tubular interstitial fibrosis in streptozocin (STZ)-induced diabetic nephropathy (ND) model mice. Twenty-seven male C57BL/6 mice were divided randomly into 3 groups: nondibetic (ND), STZ-induced diabetic (D), and STZ-induced diabetic that were treated with 5 g x kg(-1) x day(-1) of FRC by oral gavage (D(FRC)), with 9 in each group. The protein expressions of E-cadherin, alpha-smooth muscle actin (alpha-SMA), Plasminogen Activator Inhibitor-1 (PAL-1) in renal tissues were investigated by Western blotting. The expressions of fibronectin (FN) and alpha-SMA were detected by immunohistochemical method. The morphological changes of renal tissues were observed under a microscope. Renal tissues in the D(FRC) group showed a lessened degree of fibrosis. Meanwhile, the expressions of FN, alpha-SMA and PAI-1 were significantly lower in the D(FRC) group than those in the D group (all P < 0.05). FRC can ameliorate the DN in the C57BL/6 mice, and its mechanism may relate to inhibition on the epithelial to mesenchymal transdifferentiation, endothelial-myofibroblast transition and PAL-1 expression.
NASA Astrophysics Data System (ADS)
Lynn, Alan; Gilmore, Mark; Wynkoop, Tyler; Intrator, Thomas; Weber, Thomas
2012-10-01
Magnetized Target Fusion (MTF) is an innovative approach for a relatively fast and cheap path to the production of fusion energy that utilizes magnetic confinement to assist in the compression of a hot plasma to thermonuclear conditions by an external driver. Los Alamos National Laboratory (LANL) is currently pursing demonstration of the MTF concept via compression of an FRC (field-reversed configuration) plasma by a metal liner z-pinch in conjunction with the Air Force Research Laboratory in Albuquerque, NM. A key physics issue for the FRC as an MTF target lies in the initial pre-ionization (PI) stage. The PI formation process determines the amount of magnetic flux that can be trapped to form the FRC. This trapped flux plays an important role in the FRC's final equilibrium, transport, and stability properties. It also provides the route to greatest potential gains in FRC lifetime, which is essential to provide enough time to translate and compress the FRC effectively. In conjunction with LANL we plan to test and characterize a new system to improve the initial PI plasma formation. This system will use an array of plasma guns to form the initial plasma. Initial characterization of the plasma gun behavior will be presented.
Effects of cardiac oscillations and lung volume on acinar gas mixing during apnea
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mackenzie, C.F.; Skacel, M.; Barnas, G.M.
1990-05-01
We evaluated the importance of cardiogenic gas mixing in the acini of 13 dogs during 2 min of apnea. 133Xe (1-2 mCi in 4 ml of saline) was injected into an alveolar region through an occluded pulmonary artery branch, and washout was measured by gamma scintillation scanning during continued occlusion or with blood flow reinstated. The monoexponential rate constant for Xe washout (XeW) was -0.4 +/- 0.08 (SE) min-1 at functional residual capacity (FRC) with no blood flow in the injected region. It decreased by more than half at lung volumes 500 ml above and 392 ml below FRC. Withmore » intact pulmonary blood flow, XeW was -1.0 +/- 0.08 (SE) min-1 at FRC, and it increased with decreasing lung volume. However, if calculated Xe uptake by the blood was subtracted from the XeW measured with blood flow intact, resulting values at FRC and at FRC + 500 ml were not different from XeW with no blood flow. Reasonable calculation of Xe blood uptake at 392 ml below FRC was not possible because airway closure, increased shunt, and other factors affect XeW. After death, no significant XeW could be measured, which suggests that XeW caused by molecular diffusion was small. We conclude that (1) the effect of heart motion on the lung parenchyma increases acinar gas mixing during apnea, (2) this effect diminishes above or below FRC, and (3) there is probably no direct effect of pulmonary vascular pulsatility on acinar gas mixing.« less
Super-Alfvénic translation of a field-reversed configuration into a large-bore dielectric chamber
NASA Astrophysics Data System (ADS)
Sekiguchi, J.; Asai, T.; Takahashi, T.
2018-01-01
An experimental device to demonstrate additional heating and control methods for a field-reversed configuration (FRC) has been developed. The newly developed device, named FRC Amplification via Translation (FAT), has a field-reversed theta-pinch plasma source and a low-elongation dielectric (transparent quartz) confinement chamber with quasi-static confinement field. In the initial experiments on the FAT device, FRC translation and trapping were successfully demonstrated. Although the typical elongation of the trapped FRC in the confinement region was roughly three, no disruptive global instability, such as tilt, was observed. The FAT device increases the latitude to perform translation-related experiments, such as those concerning inductive current drive, equivalent neutral beam injection effects, and wave applications.
NASA Technical Reports Server (NTRS)
Schulze, Norman R.; Miley, George H.; Santarius, John F.
1991-01-01
The fusion energy conversion design approach, the Field Reversed Configuration (FRC) - when burning deuterium and helium-3, offers a new method and concept for space transportation with high energy demanding programs, like the Manned Mars Mission and planetary science outpost missions require. FRC's will increase safety, reduce costs, and enable new missions by providing a high specific power propulsion system from a high performance fusion engine system that can be optimally designed. By using spacecraft powered by FRC's the space program can fulfill High Energy Space Missions (HESM) in a manner not otherwise possible. FRC's can potentially enable the attainment of high payload mass fractions while doing so within shorter flight times.
Inductively Driven, 3D Liner Compression of a Magnetized Plasma to Megabar Energy Densities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slough, John
To take advantage of the smaller scale, higher density regime of fusion an efficient method for achieving the compressional heating required to reach fusion gain conditions must be found. What is proposed is a more flexible metallic liner compression scheme that minimizes the kinetic energy required to reach fusion. It is believed that it is possible to accomplish this at sub-megajoule energies. This however will require operation at very small scale. To have a realistic hope of inexpensive, repetitive operation, it is essential to have the liner kinetic energy under a megajoule which allows for the survivability of the vacuummore » and power systems. At small scale the implosion speed must be reasonably fast to maintain the magnetized plasma (FRC) equilibrium during compression. For limited liner kinetic energy, it becomes clear that the thinnest liner imploded to the smallest radius consistent with the requirements for FRC equilibrium lifetime is desired. The proposed work is directed toward accomplishing this goal. Typically an axial (Z) current is employed for liner compression. There are however several advantages to using a θ-pinch coil. With the θ-pinch the liner currents are inductively driven which greatly simplifies the apparatus and vacuum system, and avoids difficulties with the post implosion vacuum integrity. With fractional flux leakage, the foil liner automatically provides for the seed axial compression field. To achieve it with optimal switching techniques, and at an accelerated pace however will require additional funding. This extra expense is well justified as the compression technique that will be enabled by this funding is unique in the ability to implode individual segments of the liner at different times. This is highly advantageous as the liner can be imploded in a manner that maximizes the energy transfer to the FRC. Production of shaped liner implosions for additional axial compression can thus be readily accomplished with the modified power modules. The additional energy and switching capability proposed will thus provide for optimal utilization of the liner energy. The following tasks were outlined for the three year effort: (1) Design and assemble the foil liner compression test structure and chamber including the compression bank and test foils [Year 1]. (2) Perform foil liner compression experiments and obtain performance data over a range on liner dimensions and bank parameters [Year 2]. (3) Carry out compression experiments of the FRC plasma to Megagauss fields and measure key fusion parameters [Year 3]. (4) Develop numerical codes and analyze experimental results, and determine the physics and scaling for future work [Year 1-3]. The principle task of the project was to design and assemble the foil liner FRC formation chamber, the full compression test structure and chamber including the compression bank. This task was completed successfully. The second task was to test foils in the test facility constructed in year one and characterize the performance obtained from liner compression. These experimental measurements were then compared with analytical predictions, and numerical code results. The liner testing was completed and compared with both the analytical results as well as the code work performed with the 3D structural dynamics package of ANSYS Metaphysics®. This code is capable of modeling the dynamic behavior of materials well into the non-linear regime (e.g. a bullet hit plate glass). The liner dynamic behavior was found to be remarkably close to that predicted by the 3D structural dynamics results. Incorporating a code that can also include the magnetics and plasma physics has also made significant progress at the UW. The remaining test bed construction and assembly task is was completed, and the FRC formation and merging experiments were carried out as planned. The liner compression of the FRC to Megagauss fields was not performed due to not obtaining a sufficiently long lived FRC during the final year of the grant. Modifications planned to correct this deficiency included a larger FRC source as well as a much larger liner driver energy storage system. Due to discontinuation of the grant neither of these improvements were carried out.« less
Matias, A; Nunes, S L; Poejo, J; Mecha, E; Serra, A T; Madeira, Paulo J Amorim; Bronze, M R; Duarte, C M M
2014-12-01
In this work, Opuntia ficus indica juice was explored as a potential source of natural antioxidant and anti-inflammatory ingredients towards intestinal inflammation. An adsorption separation process was used to produce a natural flavonoid-rich concentrate (FRC) from Opuntia ficus-indica juice. The FRC effect (co- or pre-incubation) on induced-oxidative stress and induced-inflammation was evaluated in human Caco-2 cells. The main constituents identified and present in the extract are flavonoids (namely isorhamnetins and their derivatives such as isorhamnetin 3-O-rhamnose-rutinoside and isorhamnetin 3-O-rutinoside) and phenolic acids (such as ferulic, piscidic and eucomic acids). Our results showed that co-incubation of FRC with the stress-inducer attenuates radicals production in a much more significant manner than pre-incubation. These results suggest that FRC compounds which cannot pass the cell membrane freely (isorhamnetin derivatives) have an ability to inhibit the formation of H2O2-induced radicals in the surrounding environment of intestinal epithelial cells. The capacity of FRC (co-incubation) for suppressing (at the extracellular level) free radicals chain initiation or propagation reaction was probably related with a more pronounced reduction in protein oxidation. A similar response was observed in the inflammatory state, where a marked decrease in IL-8 secretion and blocked degradation of IκBα was achieved for FRC co-incubation. Simultaneously, treatment with FRC significantly reduces NO and TNF-α expression and modulates apparent permeability in Caco-2 cells. In these cases, no significant differences were found between pre- and co-incubation treatments suggesting that bioavailable phenolics, such as ferulic, eucomic and piscidic acids and isorhamnetin, act at the intracellular environment.
Poets, C F; Rau, G A; Gappa, M; Seidenberg, J
1996-06-01
The nitrogen washout technique usually involves exposure of the patient to 100% oxygen for several minutes. This may be dangerous in preterm infants who are at risk of retinopathy of prematurity (ROP). We wanted to know whether heliox (79% He, 21% O2) can be used instead of oxygen when determining functional residual capacity (FRC). FRC measurements were made in 14 preterm infants [median (range) gestational age at birth 34 wk (27-37 wk), and at time of study 36 wk (33-40 wk)] who were breathing room air. FRC was measured using a computerized infant pulmonary function system, beginning in random order with either 100% O2 followed by heliox or vice versa. There was no systematic difference between the two methods with regard to lung volume measurements: mean (SD) FRC values, corrected for body weight, were 22.9 (7.1) mL/kg for O2 and 23.4 (7.0) mL/kg for heliox. We did not observe a systematic influence of the type of washing gas used (heliox or oxygen) on FRC in these infants. Our results suggest that the use of heliox instead of pure oxygen may be a suitable and safer alternative for FRC measurements with the nitrogen washout technique in preterm infants who are breathing low concentrations of inspired oxygen and are still at risk of ROP.
Results from an 8 Joule RMF-FRC Plasma Translation Experiment for Space Propulsion
NASA Astrophysics Data System (ADS)
Hill, Carrie; Uchizono, Nolan; Holmes, Michael
2017-10-01
Field-Reversed Configuration (FRC) thrusters are attractive for advanced in-space propulsion technology as their projected performance, low specific mass, and propellant flexibility offer significant benefits over state-of-the art thrusters. A benchtop experiment to evaluate FRC thruster behavior using a Rotating Magnetic Field (RMF) formation method was constructed at the Air Force Research Laboratory. This experiment generated an RMF-FRC in a conical geometry and accelerated the plasma into a field-free drift region, using 8 J of input energy. Downstream plasma probes in a time-of-flight array measured the exhaust contents of the plasma plume. Results from this diagnostic demonstrated that the ejected mass and ion exit velocities fell short of the desired specific impulse and momentum. Two high-speed cameras were installed to diagnose the gross plasma behavior from two perspectives. Results from these images are presented here. These images show that the plasma generated in the formation region for several different operating conditions was highly non-uniform and did not form a stable closed-field topology that is expected from RMF-FRC plasmas.
Field-Reversed Configuration Power Plant Critical-Issue Scoping Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santarius, J. F.; Mogahed, E. A.; Emmert, G. A.
A team from the Universities of Wisconsin, Washington, and Illinois performed an engineering scoping study of critical issues for field-reversed configuration (FRC) power plants. The key tasks for this research were (1) systems analysis for deuterium-tritium (D-T) FRC fusion power plants, and (2) conceptual design of the blanket and shield module for an FRC fusion core. For the engineering conceptual design of the fusion core, the project team focused on intermediate-term technology. For example, one decision was to use steele structure. The FRC systems analysis led to a fusion power plant with attractive features including modest size, cylindrical symmetry, goodmore » thermal efficiency (52%), relatively easy maintenance, and a high ratio of electric power to fusion core mass, indicating that it would have favorable economics.« less
A Different Pontic Design for Fiber-Reinforced Composite Bridgeworks: A Clinical Report
Kumbuloḡlu, Ovul; Özdemir, Niler; Aksoy, Gökhan; User, Atilla
2007-01-01
Objectives This clinical report describes a relatively simple but esthetic, non-invasive and functional prosthodontic treatment option for a patient with missing tooth. Methods A patient with a missing maxillary left canine was non-invasively treated with a fiber reinforced composite (FRC) bridgework with an all ceramic (Empress II, Ivoclar Vivadent, Schaan, Liech-tenstein) pontic design, using laboratory technique. Results The restoration has served the patient for 2 year, seemingly without discomfort, and it has not required any maintenance. The patient has kept up with his oral hygiene. Conclusions Although additional clinical experience is necessary, fiber-reinforced composite materials can be used in combination with a lithium disilicate ceramic material in fixed partial dentures. PMID:19212498
Gunther, Idit; Raz, Tal; Even Zor, Yehonatan; Bachowski, Yuval; Klement, Eyal
2016-01-01
Cat feeders serve as an important source of available food for free-roaming cats (FRCs) and can play a central role in providing data on FRC distribution, welfare, and health. Data on cat feeder personalities as well as a better understanding of their feeding practices offer relevance for decision making concerning FRC population control strategies. The current study surveyed 222 FRC feeders who responded to a municipal trap-neuter-return (TNR) campaign in an Israeli central urban setting. The aim of the study was to describe their personal characteristics, feeding practices, and the FRC populations they feed. Feeders were divided into four groups according to the number of cats they claimed to feed per day (group 1: fed up to 5 cats, group 2: fed 6-10 cats, group 3: fed 11-20 cats, and group 4: fed ≥21 cats). Most feeders were women (81%), with a median age of 58 years (range 18-81). The feeders reported an overall feeding of 3337 cats in 342 different feeding locations. Feeders of group 4 comprised 15.31% (n = 34) of all feeders but fed 56% (n = 1869) of the FRC in 37.42% (n = 128) of the feeding locations. "Heavy" feeders (groups 3 and 4) reported that they traveled significantly longer distances in order to feed the cats. Commercial dry food consisted of 90% of the food they provided, with 66% of them feeding once a day, with less food per cat per day than the other feeder groups. Interestingly, "heavy" feeders were usually singles, had on average fewer siblings, a clear preference for owning cats as pets, and lived in lower income neighborhoods. According to the feeders' reports on the FRC populations they fed, 69.7% (2325/3337) cats were neutered and 11.8% (395/3337) were kittens. In addition, they reported that 1.6% (54/3337) of the cats were limping, 2% (67/3337) suffered from a systemic disease, 4% (135/3337) had skin lesions, and 3.9% (130/3337) were suffering from a chronic disability. Abundance of kittens and morbidity rate were significantly and negatively associated with neutering rate. These findings are in accordance with the suggestion that neutering may potentially improve cat welfare by reducing morbidity. Collaboration by the authorities with these heavy feeders, who represent a small number of FRC feeders and feed substantial FRC numbers, may be significant for the control and monitoring of FRC populations and their resources.
Modeling of the merging of two colliding field reversed configuration plasmoids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Guanqiong; Wang, Xiaoguang; Li, Lulu
2016-06-15
The field reversed configuration (FRC) is one of the candidate plasma targets for the magneto-inertial fusion, and a high temperature FRC can be formed by using the collision-merging technology. Although the merging process and mechanism of FRC are quite complicated, it is thinkable to build a simple model to investigate the macroscopic equilibrium parameters including the density, the temperature and the separatrix volume, which may play an important role in the collision-merging process of FRC. It is quite interesting that the estimates of the related results based on our simple model are in agreement with the simulation results of amore » two-dimensional magneto-hydrodynamic code (MFP-2D), which has being developed by our group since the last couple of years, while these results can qualitatively fit the results of C-2 experiments by Tri-alpha energy company. On the other hand, the simple model can be used to investigate how to increase the density of the merged FRC. It is found that the amplification of the density depends on the poloidal flux-increase factor and the temperature increases with the translation speed of two plasmoids.« less
Structural Applications of Fibre Reinforced Concrete in the Czech Republic
NASA Astrophysics Data System (ADS)
Kohoutková, A.; Broukalová, I.
2017-09-01
The paper presents improvement of function and performance of the precast structural members by using fibre reinforced concrete (FRC) instead of ordinary reinforced concrete and attempts to transfer innovative technologies from laboratory in academic sphere into real industrial production which is cost-effective and brings about savings of labour and material. Three examples of successful technology transfer are shown - application of FRC in an element without common rebar reinforcement, in the element with steel rebar reinforcement and SFRC pre-tensioned structural element. Benefits of FRC utilization are discussed.
Horsley, Alex; Macleod, Kenneth; Gupta, Ruchi; Goddard, Nick; Bell, Nicholas
2014-01-01
Background The Innocor device contains a highly sensitive photoacoustic gas analyser that has been used to perform multiple breath washout (MBW) measurements using very low concentrations of the tracer gas SF6. Use in smaller subjects has been restricted by the requirement for a gas analyser response time of <100 ms, in order to ensure accurate estimation of lung volumes at rapid ventilation rates. Methods A series of previously reported and novel enhancements were made to the gas analyser to produce a clinically practical system with a reduced response time. An enhanced lung model system, capable of delivering highly accurate ventilation rates and volumes, was used to assess in vitro accuracy of functional residual capacity (FRC) volume calculation and the effects of flow and gas signal alignment on this. Results 10–90% rise time was reduced from 154 to 88 ms. In an adult/child lung model, accuracy of volume calculation was −0.9 to 2.9% for all measurements, including those with ventilation rate of 30/min and FRC of 0.5 L; for the un-enhanced system, accuracy deteriorated at higher ventilation rates and smaller FRC. In a separate smaller lung model (ventilation rate 60/min, FRC 250 ml, tidal volume 100 ml), mean accuracy of FRC measurement for the enhanced system was minus 0.95% (range −3.8 to 2.0%). Error sensitivity to flow and gas signal alignment was increased by ventilation rate, smaller FRC and slower analyser response time. Conclusion The Innocor analyser can be enhanced to reliably generate highly accurate FRC measurements down at volumes as low as those simulating infant lung settings. Signal alignment is a critical factor. With these enhancements, the Innocor analyser exceeds key technical component recommendations for MBW apparatus. PMID:24892522
36 CFR 1233.20 - How are disposal clearances managed for records in NARA Federal Records Centers?
Code of Federal Regulations, 2010 CFR
2010-07-01
... NARA Federal Records Centers Program Web site (http://www.archives.gov/frc/toolkit.html#disposition...) or individual NARA Federal Records Centers (http://www.archives.gov/frc/locations.html), individual...
On the residual properties of damaged FRC
NASA Astrophysics Data System (ADS)
Zerbino, R.; Torrijos, M. C.; Giaccio, G.
2017-09-01
A discussion on the residual behaviour of Fibre Reinforced Concrete (FRC) is performed based on two selected cases of concrete degradation: the exposure at High Temperatures and the development of Alkali Silica Reactions. In addition, and taking in mind that the failure mechanism in FRC is strongly related with the fibre pull-out strength, the bond strength in damaged matrices was shown concluding that the residual bond strength is less affected than the matrix strength. As the damage increases, the compressive strength and the modulus of elasticity decrease, being the modulus of elasticity the most affected. There were no significant changes produced by the incorporation of fibres on the residual behaviour when compared with previous experience on plain damage concrete. Regarding the tensile behaviour although the first peak decreases as the damage increases, even for a severely damage FRC the residual stresses remain almost unaffected.
NASA Astrophysics Data System (ADS)
Taggart, D. P.; Gribble, R. J.; Bailey, A. D., III; Sugimoto, S.
Recently, a prototype soft x ray pinhole camera was fielded on FRX-C/LSM at Los Alamos and TRX at Spectra Technology. The soft x ray FRC images obtained using this camera stand out in high contrast to their surroundings. It was particularly useful for studying the FRC during and shortly after formation when, at certain operating conditions, flute-like structures at the edge and internal structures of the FRC were observed which other diagnostics could not resolve. Building on this early experience, a new soft x ray pinhole camera was installed on FRX-C/LSM, which permits more rapid data acquisition and briefer exposures. It will be used to continue studying FRC formation and to look for internal structure later in time which could be a signature of instability. The initial operation of this camera is summarized.
Adiabatic model and design of a translating field reversed configuration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Intrator, T. P.; Siemon, R. E.; Sieck, P. E.
We apply an adiabatic evolution model to predict the behavior of a field reversed configuration (FRC) during decompression and translation, as well as during boundary compression. Semi-empirical scaling laws, which were developed and benchmarked primarily for collisionless FRCs, are expected to remain valid even for the collisional regime of FRX-L experiment. We use this approach to outline the design implications for FRX-L, the high density translated FRC experiment at Los Alamos National Laboratory. A conical theta coil is used to accelerate the FRC to the largest practical velocity so it can enter a mirror bounded compression region, where it mustmore » be a suitable target for a magnetized target fusion (MTF) implosion. FRX-L provides the physics basis for the integrated MTF plasma compression experiment at the Shiva-Star pulsed power facility at Kirtland Air Force Research Laboratory, where the FRC will be compressed inside a flux conserving cylindrical shell.« less
High-performance fiber-reinforced concrete in a bridge deck.
DOT National Transportation Integrated Search
2005-01-01
The purpose of this research was to compare the performance of high-performance fiber-reinforced concrete (FRC) with that of conventional concrete in a bridge deck. FRC is expected to increase toughness, provide enhanced residual strength, and minimi...
Spirometry, Static Lung Volumes, and Diffusing Capacity.
Vaz Fragoso, Carlos A; Cain, Hilary C; Casaburi, Richard; Lee, Patty J; Iannone, Lynne; Leo-Summers, Linda S; Van Ness, Peter H
2017-09-01
Spirometric Z-scores from the Global Lung Initiative (GLI) rigorously account for age-related changes in lung function and are thus age-appropriate when establishing spirometric impairments, including a restrictive pattern and air-flow obstruction. However, GLI-defined spirometric impairments have not yet been evaluated regarding associations with static lung volumes (total lung capacity [TLC], functional residual capacity [FRC], and residual volume [RV]) and gas exchange (diffusing capacity). We performed a retrospective review of pulmonary function tests in subjects ≥40 y old (mean age 64.6 y), including pre-bronchodilator measures for: spirometry ( n = 2,586), static lung volumes by helium dilution with inspiratory capacity maneuver ( n = 2,586), and hemoglobin-adjusted single-breath diffusing capacity ( n = 2,508). Using multivariable linear regression, adjusted least-squares means (adj LS Means) were calculated for TLC, FRC, RV, and hemoglobin-adjusted single-breath diffusing capacity. The adj LS Means were expressed with and without height-cubed standardization and stratified by GLI-defined spirometry, including normal ( n = 1,251), restrictive pattern ( n = 663), and air-flow obstruction (mild, [ n = 128]; moderate, [ n = 150]; and severe, [ n = 394]). Relative to normal spirometry, restrictive-pattern had lower adj LS Means for TLC, FRC, RV, and hemoglobin-adjusted single-breath diffusing capacity ( P ≤ .001). Conversely, relative to normal spirometry, mild, moderate, and severe air-flow obstruction had higher adj LS Means for FRC and RV ( P < .001). However, only mild and moderate air-flow obstruction had higher adj LS Means for TLC ( P < .001), while only moderate and severe air-flow obstruction had higher adj LS Means for RV/TLC ( P < .001) and lower adj LS Means for hemoglobin-adjusted single-breath diffusing capacity ( P < .001). Notably, TLC (calculated as FRC + inspiratory capacity) was not increased in severe air-flow obstruction ( P ≥ .11) because inspiratory capacity decreased with increasing air-flow obstruction ( P < .001), thus opposing the increased FRC ( P < .001). Finally, P values were similar whether adj LS Means were height-cubed standardized. A GLI-defined spirometric restrictive pattern is strongly associated with a restrictive ventilatory defect (decreased TLC, FRC, and RV), while GLI-defined spirometric air-flow obstruction is strongly associated with hyperinflation (increased FRC) and air trapping (increased RV and RV/TLC). Both spirometric impairments were strongly associated with impaired gas exchange (decreased hemoglobin-adjusted single-breath diffusing capacity). Copyright © 2017 by Daedalus Enterprises.
Magnetized Target Fusion Collaboration. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slough, John
Nuclear fusion has the potential to satisfy the prodigious power that the world will demand in the future, but it has yet to be harnessed as a practical energy source. The entry of fusion as a viable, competitive source of power has been stymied by the challenge of finding an economical way to provide for the confinement and heating of the plasma fuel. It is the contention here that a simpler path to fusion can be achieved by creating fusion conditions in a different regime at small scale (~ a few cm). One such program now under study, referred tomore » as Magnetized Target Fusion (MTF), is directed at obtaining fusion in this high energy density regime by rapidly compressing a compact toroidal plasmoid commonly referred to as a Field Reversed Configuration (FRC). To make fusion practical at this smaller scale, an efficient method for compressing the FRC to fusion gain conditions is required. In one variant of MTF a conducting metal shell is imploded electrically. This radially compresses and heats the FRC plasmoid to fusion conditions. The closed magnetic field in the target plasmoid suppresses the thermal transport to the confining shell, thus lowering the imploding power needed to compress the target. The undertaking described in this report was to provide a suitable target FRC, as well as a simple and robust method for inserting and stopping the FRC within the imploding liner. The FRC must also survive during the time it takes for the metal liner to compress the FRC target. The initial work at the UW was focused on developing adequate preionization and flux trapping that were found to be essential in past experiments for obtaining the density, flux and most critically, FRC lifetime required for MTF. The timescale for testing and development of such a source can be rapidly accelerated by taking advantage of a new facility funded by the Department of Energy. At this facility, two inductive plasma accelerators (IPA) were constructed and tested. Recent experiments with these IPAs have demonstrated the ability to rapidly form, accelerate and merge two hypervelocity FRCs into a compression chamber. The resultant FRC that was formed was hot (T{sub ion} ~ 400 eV), stationary, and stable with a configuration lifetime several times that necessary for the MTF liner experiments. The accelerator length was less than 1 meter, and the time from the initiation of formation to the establishment of the final equilibrium was less than 10 microseconds. With some modification, each accelerator can be made capable of producing FRCs suitable for the production of the target plasma for the MTF liner experiment. Based on the initial FRC merging/compression results, the design and methodology for an experimental realization of the target plasma for the MTF liner experiment can now be defined. The construction and testing of the key components for the formation of the target plasma at the Air Force Research Laboratory (AFRL) will be performed on the IPA experiment, now at MSNW. A high density FRC plasmoid will be formed and accelerated out of each IPA into a merging/compression chamber similar to the imploding liner at AFRL. The properties of the resultant FRC plasma (size, temperature, density, flux, lifetime) will be obtained. The process will be optimized, and a final design for implementation at AFRL will be carried out. When implemented at AFRL it is anticipated that the colliding/merging FRCs will then be compressed by the liner. In this manner it is hoped that ultimately a plasma with ion temperatures reaching the 10 keV range and fusion gain near unity can be obtained.« less
Confinement of translated field-reversed configurations
NASA Astrophysics Data System (ADS)
Tuszewski, M.; Armstrong, W. T.; Chrien, R. E.; Klingner, P. L.; McKenna, K. F.; Rej, D. J.; Sherwood, E. G.; Siemon, R. E.
1986-03-01
The confinement properties of translating field-reversed configurations (FRC) in the FRX-C/T device [Phys. Fluids 29, (1986)] are analyzed and compared to previous data without translation and to available theory. Translation dynamics do not appear to appreciably modify the FRC confinement. Some empirical scaling laws with respect to various plasma parameters are extracted from the data. These are qualitatively similar to those obtained in the TRX-1 device [Phys. Fluids 28, 888 (1985)] without translation and with a different formation method. Translation with a static gas fill offers new opportunities such as improved particle confinement or refueling of the FRC particle inventory.
de Vine, Glenn; McClelland, David E; Gray, Malcolm B; Close, John D
2005-05-15
We present an experimental technique that permits mechanical-noise-free, cavity-enhanced frequency measurements of an atomic transition and its hyperfine structure. We employ the 532-nm frequency-doubled output from a Nd:YAG laser and an iodine vapor cell. The cell is placed in a folded ring cavity (FRC) with counterpropagating pump and probe beams. The FRC is locked with the Pound-Drever-Hall technique. Mechanical noise is rejected by differencing the pump and probe signals. In addition, this differenced error signal provides a sensitive measure of differential nonlinearity within the FRC.
Lesesve, J-F; Asnafi, V; Braun, F; Zini, G
2012-12-01
The diagnosis of thrombotic microangiopathies (TMA) or disorders that may mimic their features remains difficult. Mechanical hemolytic anemia with the detection of shistocytes on the blood smear is a cornerstone finding to assess the diagnosis, but microscopic evaluation of shistocytes is still problematic with wide interobserver variations. Some of the latest generation automated blood cell counters (ABCC) propose an original quantitative approach of fragmented red cells (FRC), aiming to be equivalent to the microscopic count. This parameter has been poorly evaluated. To assess the predictive value (PV) of this test, we conducted studies comparing automated and microscopic counts of FRC/schistocytes, based on the analysis of thousands samples in four university hospitals and using the 2 ABCC currently available (Siemens ADVIA series, Sysmex XE-2100). Reference range for FRC was <0.3% for the ADVIA and <0.5% for the XE-2100. The presence of FRC below a threshold determined at 1% (ADVIA and XE-2100) had a negative PV close to 100% to exclude the presence of schistocyte on the blood smear, but in relationship with a poor PV value. Our study validated the utility of the immediately available FRC parameter on ABCC to exclude schistocytes and the diagnosis of TMA. © 2012 Blackwell Publishing Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lynn, Alan
2013-11-01
The University of New Mexico (UNM) proposed a collaboration with Los Alamos National Laboratory (LANL) to develop and test methods for improved formation of field-reversed configuration (FRC) plasmas relevant to magnetized target fusion (MTF) energy research. MTF is an innovative approach for a relatively fast and cheap path to the production of fusion energy that utilizes magnetic confinement to assist in the compression of a hot plasma to thermonuclear conditions by an external driver. LANL is currently pursing demonstration of the MTF concept via compression of an FRC plasma by a metal liner z-pinch in conjunction with the Air Forcemore » Research Laboratory in Albuquerque, NM. A key physics issue for the FRC's ultimate success as an MTF target lies in the initial pre-ionization (PI) stage. The PI plasma sets the initial conditions from which the FRC is created. In particular, the PI formation process determines the amount of magnetic flux that can be trapped to form the FRC. A ringing theta pinch ionization (RTPI) technique, such as currently used by the FRX-L device at LANL, has the advantages of high ionization fraction, simplicity (since no additional coils are required), and does not require internal electrodes which can introduce impurities into the plasma. However RTPI has been shown to only trap 50% of the initial bias flux at best and imposes additional engineering constraints on the capacitor banks. The amount of trapped flux plays an important role in the FRC's final equilibrium, transport, and stability properties, and provides increased ohmic heating of the FRC through induced currents as the magnetic field decays. Increasing the trapped flux also provides the route to greatest potential gains in FRC lifetime, which is essential to provide enough time to translate and compress the FRC effectively. In conjunction with LANL we initially planned to develop and test a microwave break- down system to improve the initial PI plasma formation. The UNM team would design the microwave optics and oversee the fabrication and assembly of all components and assist with integration into the FRX-L machine control system. LANL would provide a preexisting 65 kW X-band microwave source and some associated waveguide hardware. Once constructed and installed, UNM would take the lead in operating the microwave breakdown system and conducting studies to optimize its use in FRC PI formation in close cooperation with the needs of the LANL MTF team. In conjunction with our LANL collaborators, we decided after starting the project to switch from a microwave plasma breakdown approach to a plasma gun technology to use for enhanced plasma formation in the FRX-L field-reversed configuration experiment at LANL. Plasma guns would be able to provide significantly higher density plasma with greater control over its distribution in time and space within the experiment. This would allow greater control and ne-tuning of the PI plasma formed in the experiment. Multiple plasma guns would be employed to fill a Pyrex glass test chamber (built at UNM) with plasma which would then be characterized and optimized for the MTF effort.« less
Innovative Structural Materials and Sections with Strain Hardening Cementitious Composites
NASA Astrophysics Data System (ADS)
Dey, Vikram
The motivation of this work is based on development of new construction products with strain hardening cementitious composites (SHCC) geared towards sustainable residential applications. The proposed research has three main objectives: automation of existing manufacturing systems for SHCC laminates; multi-level characterization of mechanical properties of fiber, matrix, interface and composites phases using servo-hydraulic and digital image correlation techniques. Structural behavior of these systems were predicted using ductility based design procedures using classical laminate theory and structural mechanics. SHCC sections are made up of thin sections of matrix with Portland cement based binder and fine aggregates impregnating continuous one-dimensional fibers in individual or bundle form or two/three dimensional woven, bonded or knitted textiles. Traditional fiber reinforced concrete (FRC) use random dispersed chopped fibers in the matrix at a low volume fractions, typically 1-2% to avoid to avoid fiber agglomeration and balling. In conventional FRC, fracture localization occurs immediately after the first crack, resulting in only minor improvement in toughness and tensile strength. However in SHCC systems, distribution of cracking throughout the specimen is facilitated by the fiber bridging mechanism. Influence of material properties of yarn, composition, geometry and weave patterns of textile in the behavior of laminated SHCC skin composites were investigated. Contribution of the cementitious matrix in the early age and long-term performance of laminated composites was studied with supplementary cementitious materials such as fly ash, silica fume, and wollastonite. A closed form model with classical laminate theory and ply discount method, coupled with a damage evolution model was utilized to simulate the non-linear tensile response of these composite materials. A constitutive material model developed earlier in the group was utilized to characterize and correlate the behavior of these structural composites under uniaxial tension and flexural loading responses. Development and use of analytical models enables optimal design for application of these materials in structural applications. Another area of immediate focus is the development of new construction products from SHCC laminates such as angles, channels, hat sections, closed sections with optimized cross sections. Sandwich composites with stress skin-cellular core concept were also developed to utilize strength and ductility of fabric reinforced skin in addition to thickness, ductility, and thermal benefits of cellular core materials. The proposed structurally efficient and durable sections promise to compete with wood and light gage steel based sections for lightweight construction and panel application.
[FRC measurement in intensive care patients. A definition of standards].
Wauer, H J; Lorenz, B A; Kox, W J
1998-10-01
Determination of Functional Residual Capacity (FRC) can be performed through washout methods, indicator gas dilution or bodyplethysmography. Some of these techniques have been adapted for use in intensive care patients whilst being mechanically ventilated. However, most measurement setups are bulky, cumbersome to use and their running costs are high. Hence FRC measurement has not become a routine method in intensive care although it offers considerable advantages in the management of ventilated patients such as the determination of "best PEEP", the detection of progressive alveolar collapse in the course of acute lung injury and during weaning from mechanical ventilation. Up to now most efforts to improve and simplify FRC measurement were made at the expense of accuracy. An ideal method ought to be accurate, easy to handle and cost-effective. It should supply not only FRC data but also information about intrapulmonary gas distribution and dead space. These demands can be met using modern data acquisition software. The pros and cons of all methods available for FRC measurement are discussed in view of their suitability for intensive care patients. A conventional nitrogen washout using emission spectroscopy for measurement of nitrogen concentration gives satisfying exact values for the determination of the parameters mentioned above. The measurement error can be lowered under 5% by special corrections for flow and nitrogen signal (delay and rise times, changes of gas viscosity). For flow measurement a normal pneumotachograph can be used. Using a laptop computer for data acquisition the bed-side monitor fulfills most of the demands in intensive care. It is then also possible to measure indices of intrapulmonary gas distribution such as Alveolar Mixing Efficiency and Lung Clearance Index.
van Geel, Tineke A C M; Eisman, John A; Geusens, Piet P; van den Bergh, Joop P W; Center, Jacqueline R; Dinant, Geert-Jan
2014-02-01
There are two commonly used fracture risk prediction tools FRAX(®) and Garvan Fracture Risk Calculator (GARVAN-FRC). The objective of this study was to investigate the utility of these tools in daily practice. A prospective population-based 5-year follow-up study was conducted in ten general practice centres in the Netherlands. For the analyses, the FRAX(®) and GARVAN-FRC 10-year absolute risks (FRAX(®) does not have 5-year risk prediction) for all fractures were used. Among 506 postmenopausal women aged ≥60 years (mean age: 67.8±5.8 years), 48 (9.5%) sustained a fracture during follow-up. Both tools, using BMD values, distinguish between women who did and did not fracture (10.2% vs. 6.8%, respectively for FRAX(®) and 32.4% vs. 39.1%, respectively for GARVAN-FRC, p<0.0001) at group level. However, only 8.9% of those who sustained a fracture had an estimated fracture risk ≥20% using FRAX(®) compared with 53.3% using GARVAN-FRC. Although both underestimated the observed fracture risk, the GARVAN-FRC performed significantly better for women who sustained a fracture (higher sensitivity) and FRAX(®) for women who did not sustain a fracture (higher specificity). Similar results were obtained using age related cut off points. The discriminant value of both models is at least as good as models used in other medical conditions; hence they can be used to communicate the fracture risk to patients. However, given differences in the estimated risks between FRAX(®) and GARVAN-FRC, the significance of the absolute risk must be related to country-specific recommended intervention thresholds to inform the patient. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Shrime, Mark G; Bauer, Scott R; McDonald, Anna C; Chowdhury, Nubaha H; Coltart, Cordelia E M; Ding, Eric L
2011-11-01
A growing body of evidence suggests that the consumption of foods rich in polyphenolic compounds, particularly cocoa, may have cardioprotective effects. No review, however, has yet examined the effect of flavonoid-rich cocoa (FRC) on all major cardiovascular risk factors or has examined potential dose-response relationships for these effects. A systematic review and meta-analysis of randomized, controlled trials was performed to evaluate the effect of FRC on cardiovascular risk factors and to assess a dose-response relationship. Inclusion and exclusion criteria as well as dependent and independent variables were determined a priori. Data were collected for: blood pressure, pulse, total cholesterol, HDL cholesterol, LDL cholesterol, TG, BMI, C-reactive protein, flow-mediated vascular dilation (FMD), fasting glucose, fasting insulin, serum isoprostane, and insulin sensitivity/resistance indices. Twenty-four papers, with 1106 participants, met the criteria for final analysis. In response to FRC consumption, systolic blood pressure decreased by 1.63 mm Hg (P = 0.033), LDL cholesterol decreased by 0.077 mmol/L (P = 0.038), and HDL cholesterol increased by 0.046 mmol/L (P = 0.037), whereas total cholesterol, TG, and C-reactive protein remained the same. Moreover, insulin resistance decreased (HOMA-IR: -0.94 points; P < 0.001), whereas FMD increased (1.53%; P < 0.001). A nonlinear dose-response relationship was found between FRC and FMD (P = 0.004), with maximum effect observed at a flavonoid dose of 500 mg/d; a similar relationship may exist with HDL cholesterol levels (P = 0.06). FRC consumption significantly improves blood pressure, insulin resistance, lipid profiles, and FMD. These short-term benefits warrant larger long-term investigations into the cardioprotective role of FRC.
Comparison of two techniques for removing fiber posts.
Gesi, A; Magnolfi, S; Goracci, C; Ferrari, M
2003-09-01
The purpose of this study was to evaluate the time needed to remove several types of fiber posts using two different bur kits. Estimates refer to the time needed to pass the fiber post until arriving at the gutta-percha. Sixty extracted anterior teeth were treated endodontically. A post space with a standard depth of 10 mm was prepared in each root canal. The sample was randomly divided into 3 groups of 20 specimens each. Three different types of posts were cemented: group 1, Conic 6% tapered fiber posts (Ghimas); group 2, FRC Poster fiber posts (Ivoclar-Vivadent); and group 3, Composipost carbon fiber posts (RTD). To remove the post, for half of each group's specimens the burs from the RTD fiber posts removal kit were used (subgroup A). From the other half of the teeth in each group (subgroup B), posts were removed by using a diamond bur and a Largo bur. Composipost carbon fiber posts (group 3) took significantly less time to remove than the other two types of posts (p < 0.05). For the bur kits, the procedure involving the use of a diamond and a Largo bur (subgroup B) was significantly faster (p < 0.05). The interaction between the type of post and the type of bur kit used was not significant (p > 0.05).
Harrison, Chris D; Phan, Phi Anh; Zhang, Cathy; Geer, Daniel; Farmery, Andrew D; Payne, Stephen J
2017-08-01
Routine estimation of functional residual capacity (FRC) in ventilated patients has been a long held goal, with many methods previously proposed, but none have been used in routine clinical practice. This paper proposes three models for determining FRC using the nitrous oxide concentration from the entire expired breath in order to improve the precision of the estimate. Of the three models proposed, a dead space with two mixing compartments provided the best results, reducing the mean limits of agreement with the FRC measured by whole body plethysmography by up to 41%. This moves away from traditional lung models, which do not account for mixing within the dead space. Compared to literature values for FRC, the results are similar to those obtained using helium dilution and better than the LUFU device (Dräger Medical, Lubeck, Germany), with significantly better limits of agreement compared to plethysmography. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Schmitz, L.; Ruskov, E.; Deng, B. H.; Binderbauer, M.; Tajima, T.; Gota, H.; Tuszewski, M.
2016-03-01
Control of radial particle and thermal transport is instrumental for achieving and sustaining well-confined high-β plasma in a Field-Reversed Configuration (FRC). Radial profiles of low frequency ion gyro-scale density fluctuations (0.5≤kρs≤40), consistent with drift- or drift-interchange modes, have been measured in the scrape-off layer (SOL) and core of the C-2 Field-Reversed Configuration (FRC), together with the toroidal E×B velocity. It is shown here that axial electrostatic SOL biasing controls and reduces gyro-scale density fluctuations, resulting in very low FRC core fluctuation levels. When the radial E×B flow shearing rate decreases below the turbulence decorrelation rate, fluctuation levels increase substantially, concomitantly with onset of the n=2 instability and rapid loss of diamagnetism. Low turbulence levels, improved energy/particle confinement and substantially increased FRC life times are achieved when E×B shear near the separatrix is maintained via axial SOL biasing using an annular washer gun.
Anticholinesterase activities of cold and hot aqueous extracts of F. racemosa stem bark.
Ahmed, Faiyaz; Urooj, Asna
2010-04-01
The present study evaluated the anticholinesterase activity of cold and hot aqueous extracts of Ficus racemosa stem bark against rat brain acetylcholinesterase in vitro. Both the cold aqueous extract (FRC) and the hot aqueous extract (FRH) exhibited a dose dependent inhibition of rat brain acetylcholinesterase. FRH showed significantly higher (P = 0.001) cholinesterase inhibitory activity compared to FRC; however, both the extracts did not show 50% inhibition of AChE at the doses tested (200-1000 mug ml(-1)). The IC(50) values of 1813 and 1331 mug ml(-1) were deduced for FRC and FRH, respectively (calculated by extrapolation using Boltzmann's dose response analysis).
Siew, Melissa L; Wallace, Megan J; Allison, Beth J; Kitchen, Marcus J; te Pas, Arjan B; Islam, M Sirajul; Lewis, Robert A; Fouras, Andreas; Yagi, Naoto; Uesugi, Kentaro; Hooper, Stuart B
2013-04-01
Recent phase-contrast X-ray imaging studies suggest that inspiration primarily drives lung aeration and airway liquid clearance at birth, which questions the role of adrenaline-induced activation of epithelial sodium channels (ENaCs). We hypothesized that pressures generated by inspiration have a greater role in airway liquid clearance than do ENaCs after birth. Rabbit pups (30 d of gestation) were delivered and sedated, and 0.1 ml of saline (S) or amiloride (Am; an ENaC inhibitor) was instilled into the lungs before mechanical ventilation. Two other groups (30 d of gestation) were treated similarly but were also given adrenaline (S/Ad and Am/Ad) before mechanical ventilation. Amiloride and adrenaline did not affect functional residual capacity (FRC) recruitment (P > 0.05). Amiloride increased the rate of FRC loss between inflations (Am: -5.2 ± 0.6 ml/kg/s), whereas adrenaline reduced the rate of FRC loss (S/Ad: -1.9 ± 0.3 ml/kg/s) as compared with saline-treated controls (S: -3.5 ± -0.6 ml/kg/s; P < 0.05). These data indicate that inspiration is a major determinant of airway liquid clearance and FRC development during positive pressure ventilation. Although ENaC inhibition and adrenaline administration had no detectable effect on FRC development, ENaC may help to prevent liquid from re-entering the airways during expiration.
Environmental Perturbations: Obesity
Shore, Stephanie A.
2014-01-01
Obesity currently affects about one third of the U.S. population, while another one third is overweight. The importance of obesity for certain conditions such as heart disease and type 2 diabetes is well appreciated. The effects of obesity on the respiratory system have received less attention and are the subject of this chapter. Obesity alters the static mechanic properties of the respiratory system leading to a reduction in the functional residual capacity (FRC) and the expiratory reserve volume (ERV). There is substantial variability in the effects of obesity on FRC and ERV, at least some of which is related to the location, rather than the total mass of adipose tissue. Obesity also results in airflow obstruction, which is only partially attributable to breathing at low lung volume, and can also promote airway hyperresponsiveness and asthma. Hypoxemia is common is obesity, and correlates well with FRC, as well as with measures of abdominal obesity. However, obese subjects are usually eucapnic, indicating that hypoventilation is not a common cause of their hypoxemia. Instead, hypoxemia results from ventilation perfusion mismatch caused by closure of dependent airways at FRC. Many obese subjects complain of dyspnea either at rest or during exertion, and the dyspnea score also correlates with reductions in FRC and ERV. Weight reduction should be encouraged in any symptomatic obese individual, since virtually all of the respiratory complications of obesity improve with even moderate weight loss. PMID:23737172
Oblate Field-Reversed Configuration Experiments with Neutral Beam Injection
NASA Astrophysics Data System (ADS)
T., II; Gi, K.; Umezawa, T.; Inomoto, M.; Ono, Y.
2011-11-01
The effect of energetic beam ions on oblate Field-Reversed Configurations (FRCs) has been studied experimentally in the TS-4 plasma merging device. In order to examine its kinetic effects, we developed an economical pulsed Neutral Beam Injection (NBI) system by using a washer gun plasma source and finally attained the beam power of 0.6 MW (15 kV, 40 A) for its pulse length of 0.5 ms, longer than the FRC lifetime in TS-4. The Monte Carlo simulation indicates that the tangential NB ions of 15 keV are trapped between the magnetic axis and the separatrix. We found that two merging high-s (s is plasma size normalized by ion gyroradius) hydrogen spheromaks with opposite helicities relaxed into the large scale FRC with poloidal flux as high as 15 mWb under the assistance of the NBI. Without the assistance of NBI, however, they did not relax to an FRC but to another spheromak. These facts suggest some ion kinetic effects such as toroidal ion flow are essential to FRC stability. Recently, two new NB sources with acceleration voltage and current of 15 kV and 20 A were installed on the TS-4 device on the midplane for tangential injection, increasing the beam power over 1 MW. We will start the upgraded FRC experiments using the 1 MW NBI for ion flow control.
Siegert, Stefanie; Luther, Sanjiv A.
2012-01-01
Fibroblastic reticular cells (FRC) form the structural backbone of the T cell rich zones in secondary lymphoid organs (SLO), but also actively influence the adaptive immune response. They provide a guidance path for immigrating T lymphocytes and dendritic cells (DC) and are the main local source of the cytokines CCL19, CCL21, and IL-7, all of which are thought to positively regulate T cell homeostasis and T cell interactions with DC. Recently, FRC in lymph nodes (LN) were also described to negatively regulate T cell responses in two distinct ways. During homeostasis they express and present a range of peripheral tissue antigens, thereby participating in peripheral tolerance induction of self-reactive CD8+ T cells. During acute inflammation T cells responding to foreign antigens presented on DC very quickly release pro-inflammatory cytokines such as interferon γ. These cytokines are sensed by FRC which transiently produce nitric oxide (NO) gas dampening the proliferation of neighboring T cells in a non-cognate fashion. In summary, we propose a model in which FRC engage in a bidirectional crosstalk with both DC and T cells to increase the efficiency of the T cell response. However, during an acute response, FRC limit excessive expansion and inflammatory activity of antigen-specific T cells. This negative feedback loop may help to maintain tissue integrity and function during rapid organ growth. PMID:22973278
Faifer, Marco; Ferrara, Liberato; Ottoboni, Roberto; Toscani, Sergio
2013-01-01
Non-destructive analysis of fiber dispersion in structural elements made of Fiber Reinforced Concrete (FRC) and Fiber Reinforced Cementitious Composites (FRCCs) plays a significant role in the framework of quality control and performance prediction. In this paper, the research activity of the authors in the aforementioned field all over the last lustrum will be reviewed. A method based on the measurement of the inductance of a probe to be placed on the specimen will be presented and its progressive development will be described. Obtained correlation with actual fiber dispersion, as checked by means of destructive methods, as well as with the mechanical performance of the composite will also be presented, in an attempt to address the significance of the method from an engineering application perspective. PMID:23337334
Faifer, Marco; Ferrara, Liberato; Ottoboni, Roberto; Toscani, Sergio
2013-01-21
Non-destructive analysis of fiber dispersion in structural elements made of Fiber Reinforced Concrete (FRC) and Fiber Reinforced Cementitious Composites (FRCCs) plays a significant role in the framework of quality control and performance prediction. In this paper, the research activity of the authors in the aforementioned field all over the last lustrum will be reviewed. A method based on the measurement of the inductance of a probe to be placed on the specimen will be presented and its progressive development will be described. Obtained correlation with actual fiber dispersion, as checked by means of destructive methods, as well as with the mechanical performance of the composite will also be presented, in an attempt to address the significance of the method from an engineering application perspective.
Problems encountered with conventional fiber-reinforced composites
NASA Technical Reports Server (NTRS)
Landel, R. F.
1981-01-01
Preparational, computational, and operational problems associated with fiber-reinforced composites (FRC) are reviewed. Initial preparation of FRCs is shown to involve consideration of the type of prepreg, the setting time, cure conditions and cycles, and cure temperatures. The effects of the choice of bonding agents, the fiber transfer length, and individual fiber responses to bonding agents are noted to have an impact on fiber strength, moisture uptake, and fatigue resistance. The deformation prior to failure and the failure region are modeled through models of mini-, micro- and macro mechanics formulations employing a stiffness matrix, failure criterion, or fracture mechanics. The detection, evaluation, and repair of defects comprises the operational domain, and it is stressed that no good repair techniques exist for FRCs.
Tuszewski, M; Smirnov, A; Thompson, M C; Korepanov, S; Akhmetov, T; Ivanov, A; Voskoboynikov, R; Schmitz, L; Barnes, D; Binderbauer, M W; Brown, R; Bui, D Q; Clary, R; Conroy, K D; Deng, B H; Dettrick, S A; Douglass, J D; Garate, E; Glass, F J; Gota, H; Guo, H Y; Gupta, D; Gupta, S; Kinley, J S; Knapp, K; Longman, A; Hollins, M; Li, X L; Luo, Y; Mendoza, R; Mok, Y; Necas, A; Primavera, S; Ruskov, E; Schroeder, J H; Sevier, L; Sibley, A; Song, Y; Sun, X; Trask, E; Van Drie, A D; Walters, J K; Wyman, M D
2012-06-22
Field reversed configurations (FRCs) with high confinement are obtained in the C-2 device by combining plasma gun edge biasing and neutral beam injection. The plasma gun creates an inward radial electric field that counters the usual FRC spin-up. The n = 2 rotational instability is stabilized without applying quadrupole magnetic fields. The FRCs are nearly axisymmetric, which enables fast ion confinement. The plasma gun also produces E × B shear in the FRC edge layer, which may explain the observed improved particle transport. The FRC confinement times are improved by factors 2 to 4, and the plasma lifetimes are extended from 1 to up to 4 ms.
LOS selective fading and AN/FRC-170(V) radio hybrid computer simulation phase A report
NASA Astrophysics Data System (ADS)
Klukis, M. K.; Lyon, T. I.; Walker, R.
1981-09-01
This report documents results of the first phase of modeling, simulation and study of the dual diversity AN/FRC-170(V) radio and frequency selective fading line of sight channel. Both hybrid computer and circuit technologies were used to develop a fast, accurate and flexible simulation tool to investigate changes and proposed improvements to the design of the AN/FRC-170(V) radio. In addition to the simulation study, a remote hybrid computer terminal was provided to DCEC for interactive study of the modeled radio and channel. Simulated performance of the radio for Rayleigh, line of sight two ray channels, and additive noise are included in the report.
Kumbuloglu, Ovul; Özcan, Mutlu
2015-06-01
This prospective clinical study evaluated the performance of indirect, anterior, surface-retained, fibre-reinforced-composite restorations (ISFRCR). Between June-2003 and January-2011, a total of 134 patients (83 females, 51 males, 16-68 years old) received 175 ISFRCRs (local ethical registration number: 14/9/4). All restorations were made indirectly on a plaster model using unidirectional E-glass fibres (everStick C&B, StickTech) in combination with a laboratory resin composite (Dialogue, Schütz Dental) and cemented according to the instructions of 4 resin cements [(RelyX ARC, 3M-ESPE, n=61), Bifix DC, VOCO, n=45), Variolink II (Ivoclar Vivadent, n=32) and Multilink (Ivoclar Vivadent, n=37)]. After baseline recordings, patients were followed at 6 months and thereafter annually up to 7.5 years. The evaluation protocol involved technical (chipping, debonding or fracture of tooth/restoration) and biological failures (caries). Mean observation period was 58 months. Altogether, 13 failures were observed [survival rate: 97.7%] (Kaplan-Meier). One catastrophic fracture [(cement: RelyX ARC), eight partial debonding (cement: Bifix DC (5), Multilink (1), RelyX ARC (1), Variolink II (1)] and four delaminations of veneering composite [(cement: Bifix DC (2), RelyX ARC (1), Multilink (1)] were observed. Except one replacement, all defective restorations were repaired or recemented. Annual failure rate of ISFRCRs was 1.73%. The survival rates with the four resin cements did not show significant differences (RelyX ARC: 98.3%; Bifix DC: 93.5%; Variolink 2: 100%; Multilink: 100%) (p=0.114). Secondary caries did not occur in any of the teeth. The 3-unit anterior indirect surface-retained resin-bonded FRC FDPs showed similar clinical survival rate when cemented with the resin cements tested. Experienced failures in general were due to debonding of the restoration or delamination of the veneering composite. 3-unit surface retained resin-bonded FRC FDPs could be considered minimal invasive and cost-effective alternatives to conventional tooth- or implant-borne FDPs. Failures were mainly repairable in the form of chipping or debonding depending on the resin cement type. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Aubree, Nathan
Since 1990, constitutive concrete model EPM3D (Multiaxial Progressive Damage in 3 Dimensions) has been developed at Polytechnique Montreal. Bouzaiene and Massicotte (1995) choose the hypoelastic approach with the concept of equivalent deformation and the implementation of a scalar damage parameter to represent the microcracking of concrete in pre-peak compression. The post-peak softening behaviour, in tension and in compression, is based on the concept of conservation of the fracture energy. In the finite elements context, it requires defining a localisation limiter acting on the softening modulus depending on the element size. The formulation of EPM3D model in the case of the post-peak compression required revisions. Mesh-dependence problems and the absence of the consideration of the confinement effect were the most important points to improve, with as main goal the modelling of the fracture of the reinforced concrete columns. With a complete literature review, we try to establish an exhaustive list of the numerous parameters having an influence on the softening behavior under uniaxial and multiaxial loads. In the second part of this review, we exhibit the difficulties of modelling a softening material with finite elements theory and the principle of the set up localization limiter. Inspired by models we met in literature, modifications of the previously established relation are proposed by focusing on a more adequate representation of the behavior under confinement loads. Then we proceed to the validation of the model by means of simple analyses with the software ABAQUS and the module of explicit dynamic resolution, called Explicit. Also we present its specificities compared with a classic implicit static resolution. We supply some advice to the reader and future students who are susceptible to model real reinforced concrete columns with EPM3D. Finally we made an experimental program to characterize the post-peak behavior in uniaxial compression of a fiber reinforced concrete mixture (FRC) with the aim of considering the possibility or not of an extrapolation of our model for FRC.
Gunther, I; Raz, T; Berke, O; Klement, E
2015-05-01
Free roaming cats (FRC) are highly abundant in cities around the world. Increasing populations of these cats might result in impairment of cat welfare and cause nuisances and public health risks. In order to study the seasonal dynamics of FRC populations and its association with events of cat welfare impairment and nuisances, we analyzed a database of FRC-associated citizens' telephone complaint events, which were registered in five cities in Israel (total human population of 1.42 million residents) during the years 2007-2011. These complaint events were classified to the following six categories: cat's carcasses, kittens, parturition, aggressive behavior toward people, invasion to human facilities, and cat injuries and distress. Overall, 87,764 complaint events associated with these categories were registered in the five cities during the study period (123.2 complaint events per 10,000 citizens per year). Length of daylight was moderately correlated with the rate of complaints on kittens in the same month (r=0.64) and parturition in the previous month (r=0.54) (P<0.001). Both kitten and parturition-related complaints showed a prominent seasonal pattern, peaking in April and May, respectively, and declining gradually until November. 'Kittens' or 'parturition' were explicitly mentioned in 38%, 39% and 19%, respectively, of the complaints regarding cat aggressiveness toward people, cat invasion to human facilities and cat injuries and distress. In most of the cities the rate of citizen complaints regarding carcasses, aggression, invasion and injuries were still significantly correlated with rate of complaints regarding kittens after omission of these joint complaints and remained significant after controlling for seasonality. These findings imply an association of cat welfare impairment and nuisances with FRC reproduction intensity. The current study revealed the high rate of nuisances and potential public health hazards related to FRC, as well as the impairment of cat welfare, which might be merely 'the tip of the iceberg' of the real welfare situation of these cats. Further studies should examine the effectiveness of FRC population control strategies for the reduction of the rate of nuisances and public health risks related to FRC, as well as for improving their welfare. Copyright © 2015 Elsevier B.V. All rights reserved.
Final report on the Magnetized Target Fusion Collaboration
DOE Office of Scientific and Technical Information (OSTI.GOV)
John Slough
Nuclear fusion has the potential to satisfy the prodigious power that the world will demand in the future, but it has yet to be harnessed as a practical energy source. The entry of fusion as a viable, competitive source of power has been stymied by the challenge of finding an economical way to provide for the confinement and heating of the plasma fuel. It is the contention here that a simpler path to fusion can be achieved by creating fusion conditions in a different regime at small scale (~ a few cm). One such program now under study, referred tomore » as Magnetized Target Fusion (MTF), is directed at obtaining fusion in this high energy density regime by rapidly compressing a compact toroidal plasmoid commonly referred to as a Field Reversed Configuration (FRC). To make fusion practical at this smaller scale, an efficient method for compressing the FRC to fusion gain conditions is required. In one variant of MTF a conducting metal shell is imploded electrically. This radially compresses and heats the FRC plasmoid to fusion conditions. The closed magnetic field in the target plasmoid suppresses the thermal transport to the confining shell, thus lowering the imploding power needed to compress the target. The undertaking to be described in this proposal is to provide a suitable target FRC, as well as a simple and robust method for inserting and stopping the FRC within the imploding liner. The timescale for testing and development can be rapidly accelerated by taking advantage of a new facility funded by the Department of Energy. At this facility, two inductive plasma accelerators (IPA) were constructed and tested. Recent experiments with these IPAs have demonstrated the ability to rapidly form, accelerate and merge two hypervelocity FRCs into a compression chamber. The resultant FRC that was formed was hot (T&ion ~ 400 eV), stationary, and stable with a configuration lifetime several times that necessary for the MTF liner experiments. The accelerator length was less than 1 meter, and the time from the initiation of formation to the establishment of the final equilibrium was less than 10 microseconds. With some modification, each accelerator was made capable of producing FRCs suitable for the production of the target plasma for the MTF liner experiment. Based on the initial FRC merging/compression results, the design and methodology for an experimental realization of the target plasma for the MTF liner experiment can now be defined. A high density FRC plasmoid is to be formed and accelerated out of each IPA into a merging/compression chamber similar to the imploding liner at AFRL. The properties of the resultant FRC plasma (size, temperature, density, flux, lifetime) are obtained in the reevant regime of interest. The process still needs to be optimized, and a final design for implementation at AFRL must now be carried out. When implemented at AFRL it is anticipated that the colliding/merging FRCs will then be compressed by the liner. In this manner it is hoped that ultimately a plasma with ion temperatures reaching the 10 keV range and fusion gain near unity can be obtained.« less
Time-Resolved Emission Spectroscopy of Field Reversed Configuration Thruster
2016-08-31
radiation Collection Optics to 600um fiber Source: Scharer Research Group Source: PEARL 1. Acquire Spectrum 2. Compare to Collisional‐Radiative Model ( CRM ...calibration (deuterium lamp) • Obtain Argon FRC data and use Collisional Radiative Model ( CRM ) to extract plasma properties • Apply knowledge to improve FRC
Conservative Bin-to-Bin Fractional Collisions
2016-06-28
BIN FRACTIONAL COLLISIONS Robert Martin ERC INC., SPACECRAFT PROPULSION BRANCH AIR FORCE RESEARCH LABORATORY EDWARDS AIR FORCE BASE, CA USA 30th...IMPORTANCE OF COLLISION PHYSICS Important Collisions in Spacecraft Propulsion : Discharge and Breakdown in FRC Collisional Radiative Cooling/Ionization...UNLIMITED; PA #16326 3 / 18 IMPORTANCE OF COLLISION PHYSICS Important Collisions in Spacecraft Propulsion : Discharge and Breakdown in FRC Collisional
Effects of breathing exercises on breathing patterns in obese and non-obese subjects.
Olsén, M F; Lönroth, H; Bake, B
1999-05-01
Chest physiotherapy in connection with abdominal surgery includes different deep-breathing exercises to prevent post-operative pulmonary complications. The therapy is effective in preventing pulmonary complications, especially in high-risk patients such as obese persons. The mechanisms behind the effect is unclear, but part of the effect may be explained by the changes in breathing patterns. The aim of this study was therefore to describe and to analyse the breathing patterns in obese and non-obese subjects during three different breathing techniques frequently used in the treatment of post-operative patients. Twenty-one severely obese [body mass index (BMI) > 40] and 21 non-obese (BMI 19-25) subjects were studied. All persons denied having any lung disease and were non-smokers. The breathing techniques investigated were: deep breaths without any resistance (DB), positive expiratory pressure (PEP) with an airway resistance of approximately +15 cmH2O (1.5 kPa) during expiration, inspiratory resistance positive expiratory pressure (IR-PEP) with a pressure of approximately -10 cmH2O (-1.0 kPa) during inspiration. Expiratory resistance as for PEP. Volume against time was monitored while the subjects were sitting in a body plethysmograph. Variables for volume and flow during the breathing cycle were determined. Tidal volume and alveolar ventilation were highest during DB, and peak inspiratory volume was significantly higher than during PEP and IR-PEP in the group of obese subjects. The breathing cycles were prolonged in all techniques but were most prolonged in PEP and IR-PEP. The functional residual capacity (FRC) was significantly lower during DB than during PEP and IR-PEP in the group of obese subjects. FRC as determined within 2 min of finishing each breathing technique was identical to before the breathing manoeuvres.
Compact toroid injection fueling in a large field-reversed configuration
NASA Astrophysics Data System (ADS)
Asai, T.; Matsumoto, T.; Roche, T.; Allfrey, I.; Gota, H.; Sekiguchi, J.; Edo, T.; Garate, E.; Takahashi, Ts.; Binderbauer, M.; Tajima, T.
2017-07-01
A repetitively driven compact toroid (CT) injector has been developed for the large field-reversed configuration (FRC) facility of the C-2/C-2U, primarily for particle refueling. A CT is formed and injected by a magnetized coaxial plasma gun (MCPG) exclusively developed for the C-2/C-2U FRC. To refuel the particles of long-lived FRCs, multiple CT injections are required. Thus, a multi-stage discharge circuit was developed for a multi-pulsed CT injection. The drive frequency of this system can be adjusted up to 1 kHz and the number of CT shots per injector is two; the system can be further upgraded for a larger number of injection pulses. The developed MCPG can achieve a supersonic ejection velocity in the range of ~100 km s-1. The key plasma parameters of electron density, electron temperature and the number of particles are ~5 × 1021 m-3, ~30 eV and 0.5-1.0 × 1019, respectively. In this project, single- and double-pulsed counter CT injection fueling were conducted on the C-2/C-2U facility by two CT injectors. The CT injectors were mounted 1 m apart in the vicinity of the mid-plane. To avoid disruptive perturbation on the FRC, the CT injectors were operated at the lower limit of the particle inventory. The experiments demonstrated successful refueling with a significant density build-up of 20-30% of the FRC particle inventory per single CT injection without any deleterious effects on the C-2/C-2U FRC.
Increased Lung Volume in Infants and Toddlers at High Compared to Low Altitude
Llapur, Conrado J.; Martínez, Myriam R.; Caram, María Marta; Bonilla, Federico; Cabana, Celia; Yu, Zhansheng; Tepper, Robert S.
2015-01-01
Summary Children and adults residing at high altitude (HA) compared to low altitude (LA) have larger lung volumes; however, it is unknown whether this response to chronic hypoxia begins early in life. Our objective was to determine whether infants and toddlers at HA have larger lung volumes compared to infants and toddlers at LA. Oxygen saturation (SaO2), functional residual capacity (FRC), as well as serum levels of vascular endothelial growth factor (VEGF) and erythropoietin (EPO) were measured in infants and toddlers from HA (N = 50; 3,440 m) and LA (N = 35; 440 m). There were no significant differences in somatic size for HA and LA subjects; however, HA subjects had significantly lower SaO2 (88.5% vs. 96.7%; P < 0.0001). Subjects at HA had significantly greater FRC compared to subjects at LA (group mean: 209 and 157 ml; P < 0.0001), adjusting for body length. Male infants at HA had a significantly greater FRC compared to males at LA (57 ml; P-value < 0.001); however, the increase in FRC for females at HA compared to LA was not significant (20 ml; P-value = 0.101). VEGF and EPO were significantly higher for subjects at HA compared to LA with no gender differences. In summary, infants and toddlers at HA have lower oxygen saturations, higher serum levels of VEGF and EPO, and higher FRC compared to subjects at LA; however, chronic hypoxia appears to generate a more robust response in lung growth in male compared to female infants early in life. PMID:23401418
Silva, Andréia do Socorro de Sousa; Baraúna, Rafael Azevedo; de Sá, Pablo Caracciolo Gomes; das Graças, Diego Assis; Carneiro, Adriana Ribeiro; Thouvenin, Maxime; Azevedo, Vasco; Badell, Edgar; Guiso, Nicole; da Silva, Artur Luiz da Costa
2014-01-01
Corynebacterium ulcerans is a bacterial species with high importance because it causes infections in animals and, rarely, in humans. Its virulence mechanisms remain unclear. The current study describes the draft genome of C. ulcerans FRC58, which was isolated from the bronchitic aspiration of a patient in France. PMID:24407640
Separating Spike Count Correlation from Firing Rate Correlation
Vinci, Giuseppe; Ventura, Valérie; Smith, Matthew A.; Kass, Robert E.
2016-01-01
Populations of cortical neurons exhibit shared fluctuations in spiking activity over time. When measured for a pair of neurons over multiple repetitions of an identical stimulus, this phenomenon emerges as correlated trial-to-trial response variability via spike count correlation (SCC). However, spike counts can be viewed as noisy versions of firing rates, which can vary from trial to trial. From this perspective, the SCC for a pair of neurons becomes a noisy version of the corresponding firing-rate correlation (FRC). Furthermore, the magnitude of the SCC is generally smaller than that of the FRC, and is likely to be less sensitive to experimental manipulation. We provide statistical methods for disambiguating time-averaged drive from within-trial noise, thereby separating FRC from SCC. We study these methods to document their reliability, and we apply them to neurons recorded in vivo from area V4, in an alert animal. We show how the various effects we describe are reflected in the data: within-trial effects are largely negligible, while attenuation due to trial-to-trial variation dominates, and frequently produces comparisons in SCC that, because of noise, do not accurately reflect those based on the underlying FRC. PMID:26942746
Direct Measurement of Impurity Transport in a Field Reversed Configuration
NASA Astrophysics Data System (ADS)
Roche, T.; Bolte, N.; Heidbrink, W. W.; McWilliams, R.; Wessel, F.
2011-10-01
An optical tomography system has been developed and implemented in the Flux Coil Generated Field Reversed Configuration (FCG-FRC) at Tri Alpha Energy. Sixteen chords view ~ 35 % of the FRC at the mid-plane. The chords are arranged in two identical fans of eight chords each. To measure transport of an impurity species, argon, an FRC is generated using either Nitrogen or Deuterium as the primary species. A puff valve is activated prior to the shot such that the argon begins to bleed in to the vacuum chamber as the FRC is formed. The gas is puffed at the optimal location for tomographic reconstruction. Each chord is collimated to illuminate a fiber optic cable which is fed to an array of photomultiplier tubes which are fitted with neutral density and band pass filters to allow the appropriate amount of light from the emitting, singly ionized, argon at 434 . 8 nm to be measured. Using a preliminary assumption that density of argon is proportional to light intensity gathered data have been used to reconstruct density profiles. These profiles often peak near the field null. The data are being analyzed to determine diffusive and convective transport coefficients.
Numerical Study of HHFW Heating in FRC Plasmas
NASA Astrophysics Data System (ADS)
Ceccherini, Francesco; Galeotti, Laura; Brambilla, Marco; Dettrick, Sean; Yang, Xiaokang; TAE Team
2017-10-01
The TriAlpha Energy (TAE) code RF-Pisa is a Finite Larmor Radius (FLR) full wave code developed over the years to study RF heating in the Field Reversed Configuration (FRC) in both the ion and electron cyclotron regimes. The FLR approximation is perfectly adequate to address RF propagation and absorption at the fundamental and second harmonic frequencies (as in the minority heating scheme), but it is not able to describe higher order processes such as high-harmonic fast waves (HHFW). The latter ones have frequencies lying between the ion cyclotron and lower hybrid resonances and they may represent a viable path to develop an efficient method to deposit energy inside the FRC separatrix, as suggested by recent results obtained at NSTX. A significant upgrade of RF-Pisa to include HHFW has been undertaken. In particular, the so-called ``quasi local approximation'' originally proposed for toroidal geometries has been re-derived for the cylindrical geometry and a new HHFW version of RF-Pisa concurrent to the FLR version has been developed. Here we present the first results of the application of the new code to FRC equilibria and we discuss the features of the dispersion relations and the absorption processes which characterize this novel regime.
NASA Astrophysics Data System (ADS)
Enfedaque, A.; Alberti, M. G.; Gálvez, J. C.
2017-09-01
The relevance of fibre reinforced cementitious materials (FRC) has increased due to the appearance of regulations that establish the requirements needed to take into account the contribution of the fibres in the structural design. However, in order to exploit the properties of such materials it is a key aspect being able to simulate their behaviour under fracture conditions. Considering a cohesive crack approach, several authors have studied the suitability of using several softening functions. However, none of these functions can be directly applied to FRC. The present contribution analyses the suitability of multilinear softening functions in order to obtain simulation results of fracture tests of a wide variety of FRC. The implementation of multilinear softening functions has been successfully performed by means of a material user subroutine in a commercial finite element code obtaining accurate results in a wide variety of FRC. Such softening functions were capable of simulating a ductile unloading behaviour as well as a rapid unloading followed by a reloading and afterwards a slow unloading. Moreover, the implementation performed has been proven as versatile, robust and efficient from a numerical point of view.
Auto-magnetizing liners for magnetized inertial fusion
Slutz, S. A.; Jennings, C. A.; Awe, T. J.; ...
2017-01-20
Here, the MagLIF (Magnetized Liner Inertial Fusion) concept has demonstrated fusion-relevant plasma conditions on the Z accelerator using external field coils to magnetize the fuel before compression. We present a novel concept (AutoMag), which uses a composite liner with helical conduction paths separated by insulating material to provide fuel magnetization from the early part of the drive current, which by design rises slowly enough to avoid electrical breakdown of the insulators. Once the magnetization field is established, the drive current rises more quickly, which causes the insulators to break down allowing the drive current to follow an axial path andmore » implode the liner in the conventional z-pinch manner. There are two important advantages to AutoMag over external field coils for the operation of MagLIF. Low inductance magnetically insulated power feeds can be used to increase the drive current, and AutoMag does not interfere with diagnostic access. Also, AutoMag enables a pathway to energy applications for MagLIF, since expensive field coils will not be damaged each shot. Finally, it should be possible to generate Field Reversed Configurations (FRC) by using both external field coils and AutoMag in opposite polarities. This would provide a means to studying FRC liner implosions on the 100 ns time scale.« less
Prakash, Om; Gihring, Thomas M; Dalton, Dava D; Chin, Kuk-Jeong; Green, Stefan J; Akob, Denise M; Wanger, Greg; Kostka, Joel E
2010-03-01
An Fe(III)- and uranium(VI)-reducing bacterium, designated strain FRC-32(T), was isolated from a contaminated subsurface of the USA Department of Energy Oak Ridge Field Research Center (ORFRC) in Oak Ridge, Tennessee, where the sediments are exposed to mixed waste contamination of radionuclides and hydrocarbons. Analyses of both 16S rRNA gene and the Geobacteraceae-specific citrate synthase (gltA) mRNA gene sequences retrieved from ORFRC sediments indicated that this strain was abundant and active in ORFRC subsurface sediments undergoing uranium(VI) bioremediation. The organism belonged to the subsurface clade of the genus Geobacter and shared 92-98 % 16S rRNA gene and 75-81 % rpoB gene sequence similarities with other recognized species of the genus. In comparison to its closest relative, Geobacter uraniireducens Rf4(T), according to 16S rRNA gene sequence similarity, strain FRC-32(T) showed a DNA-DNA relatedness value of 21 %. Cells of strain FRC-32(T) were Gram-negative, non-spore-forming, curved rods, 1.0-1.5 microm long and 0.3-0.5 microm in diameter; the cells formed pink colonies in a semisolid cultivation medium, a characteristic feature of the genus Geobacter. The isolate was an obligate anaerobe, had temperature and pH optima for growth at 30 degrees C and pH 6.7-7.3, respectively, and could tolerate up to 0.7 % NaCl although growth was better in the absence of NaCl. Similar to other members of the Geobacter group, strain FRC-32(T) conserved energy for growth from the respiration of Fe(III)-oxyhydroxide coupled with the oxidation of acetate. Strain FRC-32(T) was metabolically versatile and, unlike its closest relative, G. uraniireducens, was capable of utilizing formate, butyrate and butanol as electron donors and soluble ferric iron (as ferric citrate) and elemental sulfur as electron acceptors. Growth on aromatic compounds including benzoate and toluene was predicted from preliminary genomic analyses and was confirmed through successive transfer with fumarate as the electron acceptor. Thus, based on genotypic, phylogenetic and phenotypic differences, strain FRC-32(T) is considered to represent a novel species of the genus Geobacter, for which the name Geobacter daltonii sp. nov. is proposed. The type strain is FRC-32(T) (=DSM 22248(T)=JCM 15807(T)).
High Fidelity Modeling of Field Reversed Configuration (FRC) Thrusters
2016-06-01
space propulsion . This effort consists of numerical model development, physical model development, and systematic studies of the non-linear plasma...studies of the physical characteristics of Field Reversed Configuration (FRC) plasma for advanced space propulsion . This effort consists of numerical...FRCs for propulsion application. Two of the most advanced designs are based on the theta-pinch formation and the RMF formation mechanism, which
Oxidative dissolution potential of biogenic and abiogenic TcO 2 in subsurface sediments
NASA Astrophysics Data System (ADS)
Fredrickson, James K.; Zachara, John M.; Plymale, Andrew E.; Heald, Steve M.; McKinley, James P.; Kennedy, David W.; Liu, Chongxuan; Nachimuthu, Ponnusamy
2009-04-01
Technetium-99 (Tc) is an important fission product contaminant associated with sites of nuclear fuels reprocessing and geologic nuclear waste disposal. Tc is highly mobile in its most oxidized state [Tc(VII)O4-] and less mobile in the reduced form [Tc(IV)O 2· nH 2O]. Here we investigate the potential for oxidation of Tc(IV) that was heterogeneously reduced by reaction with biogenic Fe(II) in two sediments differing in mineralogy and aggregation state; unconsolidated Pliocene-age fluvial sediment from the upper Ringold (RG) Formation at the Hanford Site and a clay-rich saprolite from the Field Research Center (FRC) background site on the Oak Ridge Site. Both sediments contained Fe(III) and Mn(III/IV) as redox active phases, but FRC also contained mass-dominant Fe-phyllosilicates of different types. Shewanella putrefaciens CN32 reduced Mn(III/IV) oxides and generated Fe(II) that was reactive with Tc(VII) in heat-killed, bioreduced sediment. After bioreduction and heat-killing, biogenic Fe(II) in the FRC exceeded that in RG by a factor of two. More rapid reduction rates were observed in the RG that had lower biogenic Fe(II), and less particle aggregation. EXAFS measurements indicated that the primary reduction product was a TcO 2-like phase in both sediments. The biogenic redox product Tc(IV) oxidized rapidly and completely in RG when contacted with air. Oxidation, in contrast, was slow and incomplete in the FRC, in spite of similar molecular scale speciation of Tc compared to RG. X-ray microprobe, electron microprobe, X-ray absorption spectroscopy, and micro X-ray diffraction were applied to the whole sediment and isolated Tc-containing particles. These analyses revealed that non-oxidizable Tc(IV) in the FRC existed as complexes with octahedral Fe(III) within intra-grain domains of 50-100 μm-sized, Fe-containing micas presumptively identified as celadonite. The markedly slower oxidation rates in FRC as compared to RG were attributed to mass-transfer-limited migration of O 2 into intra-aggregate and intraparticle domains where Tc(IV) existed; and the formation of unique, oxidation-resistant, intragrain Tc(IV)-Fe(III) molecular species.
Increased lung volume in infants and toddlers at high compared to low altitude.
Llapur, Conrado J; Martínez, Myriam R; Caram, María Marta; Bonilla, Federico; Cabana, Celia; Yu, Zhansheng; Tepper, Robert S
2013-12-01
Children and adults residing at high altitude (HA) compared to low altitude (LA) have larger lung volumes; however, it is unknown whether this response to chronic hypoxia begins early in life. Our objective was to determine whether infants and toddlers at HA have larger lung volumes compared to infants and toddlers at LA. Oxygen saturation (SaO2 ), functional residual capacity (FRC), as well as serum levels of vascular endothelial growth factor (VEGF) and erythropoietin (EPO) were measured in infants and toddlers from HA (N = 50; 3,440 m) and LA (N = 35; 440 m). There were no significant differences in somatic size for HA and LA subjects; however, HA subjects had significantly lower SaO2 (88.5% vs. 96.7%; P < 0.0001). Subjects at HA had significantly greater FRC compared to subjects at LA (group mean: 209 and 157 ml; P < 0.0001), adjusting for body length. Male infants at HA had a significantly greater FRC compared to males at LA (57 ml; P-value < 0.001); however, the increase in FRC for females at HA compared to LA was not significant (20 ml; P-value = 0.101). VEGF and EPO were significantly higher for subjects at HA compared to LA with no gender differences. In summary, infants and toddlers at HA have lower oxygen saturations, higher serum levels of VEGF and EPO, and higher FRC compared to subjects at LA; however, chronic hypoxia appears to generate a more robust response in lung growth in male compared to female infants early in life. © 2013 Wiley Periodicals, Inc.
CPAP of 4 cm H(2)O Has no short-term benefit at term in infants with BPD.
Sandberg, Kenneth L; Hjalmarson, Ola
2012-01-01
Lung development and function is compromised at term in infants with bronchopulmonary dysplasia (BPD), characterized by reduced functional residual capacity (FRC) and impaired gas-mixing efficiency in distal airways. To determine whether continuous positive airway pressure (CPAP) improves FRC, ventilation, distal airway function, and gas exchange in spontaneously breathing infants with BPD. Twenty-one infants with BPD (median birth weight 0.72 kg (range 0.50-1.27) and median gestational age 26 weeks (range 23-28)) were studied before and after CPAP of 4 cm H(2)O was applied by a facemask system. A multiple-breath nitrogen washout method was used to assess FRC, ventilation, and gas-mixing efficiency. Moment analysis and lung clearance index was calculated from the nitrogen-decay curve for assessment of gas-mixing efficiency. Transcutaneous (Tc) PO(2)/PCO(2) was monitored during stable infant conditions before each washout test. When CPAP was raised from 0 to 4 cm H(2)O, FRC increased significantly together with a significant increase in moment ratios (M(1)/M(0) and M(2)/M(0)). Tc PO(2) decreased significantly and the breathing pattern changed, with significantly reduced respiratory rate, minute ventilation, and alveolar ventilation. There was also an increase in tidal volume and dead space. CPAP of 4 cm H(2)O applied with a facemask at term to infants with BPD did not improve ventilation, gas-mixing efficiency in distal airways, or oxygenation despite an increase in FRC. We speculate that instead of promoting recruitment of unventilated lung volumes, increasing the end-expiratory pressure in infants with BPD may lead to an overexpansion of already ventilated parts of the lung, causing further compromise of lung function. Copyright © 2012 S. Karger AG, Basel.
Open lung ventilation improves functional residual capacity after extubation in cardiac surgery.
Reis Miranda, Dinis; Struijs, Ard; Koetsier, Peter; van Thiel, Robert; Schepp, Ronald; Hop, Wim; Klein, Jan; Lachmann, Burkhard; Bogers, Ad J J C; Gommers, Diederik
2005-10-01
After cardiac surgery, functional residual capacity (FRC) after extubation is reduced significantly. We hypothesized that ventilation according to the open lung concept (OLC) attenuates FRC reduction after extubation. A prospective, single-center, randomized, controlled clinical study. Cardiothoracic operating room and intensive care unit of a university hospital. Sixty-nine patients scheduled for elective coronary artery bypass graft and/or valve surgery with cardiopulmonary bypass. Before surgery, patients were randomly assigned to three groups: (1) conventional ventilation (CV); (2) OLC, started after arrival in the intensive care unit (late open lung); and (3) OLC, started directly after intubation (early open lung). In both OLC groups, recruitment maneuvers were applied until Pao2/Fio2 was >375 Torr (50 kPa). No recruitment maneuvers were applied in the CV group. FRC was measured preoperatively and 1, 3, and 5 days after extubation. Peripheral hemoglobin saturation (Spo2) was measured daily till the third day after extubation while the patient was breathing room air. Hypoxemia was defined by an Spo2 value < or =90%. Averaged over the 5 postoperative days, FRC was significantly higher in the early open lung group and tended to be higher in the late open lung group, in comparison with the CV group (mean +/- sem: CV, 1.8 +/- 0.1; late open lung,1.9 +/- 0.1; and early open lung, 2.2 +/- 0.1l). In the CV group, 37% of the patients were hypoxic on the third day after extubation, compared with none of the patients in both OLC groups. After cardiac surgery, earlier application of OLC resulted in a significantly higher FRC and fewer episodes of hypoxemia than with CV after extubation.
Comparison of four software packages for CT lung volumetry in healthy individuals.
Nemec, Stefan F; Molinari, Francesco; Dufresne, Valerie; Gosset, Natacha; Silva, Mario; Bankier, Alexander A
2015-06-01
To compare CT lung volumetry (CTLV) measurements provided by different software packages, and to provide normative data for lung densitometric measurements in healthy individuals. This retrospective study included 51 chest CTs of 17 volunteers (eight men and nine women; mean age, 30 ± 6 years), who underwent spirometrically monitored CT at total lung capacity (TLC), functional residual capacity (FRC), and mean inspiratory capacity (MIC). Volumetric differences assessed by four commercial software packages were compared with analysis of variance (ANOVA) for repeated measurements and benchmarked against the threshold for acceptable variability between spirometric measurements. Mean lung density (MLD) and parenchymal heterogeneity (MLD-SD) were also compared with ANOVA. Volumetric differences ranged from 12 to 213 ml (0.20 % to 6.45 %). Although 16/18 comparisons (among four software packages at TLC, MIC, and FRC) were statistically significant (P < 0.001 to P = 0.004), only 3/18 comparisons, one at MIC and two at FRC, exceeded the spirometry variability threshold. MLD and MLD-SD significantly increased with decreasing volumes, and were significantly larger in lower compared to upper lobes (P < 0.001). Lung volumetric differences provided by different software packages are small. These differences should not be interpreted based on statistical significance alone, but together with absolute volumetric differences. • Volumetric differences, assessed by different CTLV software, are small but statistically significant. • Volumetric differences are smaller at TLC than at MIC and FRC. • Volumetric differences rarely exceed spirometric repeatability thresholds at MIC and FRC. • Differences between CTLV measurements should be interpreted based on comparison of absolute differences. • MLD increases with decreasing volumes, and is larger in lower compared to upper lobes.
Zhang, Jie; Patterson, Robert
2010-08-01
Lung resistivity is a physiological parameter that describes the electrical characteristics of the lungs. Lung composition changes due to changes in the lung tissues, fluid and air volume. Various diseases that can cause a change in lung composition may be monitored by measuring lung resistivity. Currently, there is no accepted non-invasive method to measure lung resistivity. In this study, we presented a method and framework to non-invasively determine lung resistivity using electrical impedance tomography (EIT). By comparing actual measurements from subjects with data from a 3D human thorax model, an EIT image can be reconstructed to show a resistivity difference between the model and the subject. By adjusting the lung resistivity in the model, the resistivity difference in the lung regions can be reduced to near zero. This resistivity value then is the estimation of the lung resistivity of the subject. Using the proposed method, the lung resistivities of four normal adult males (43 +/- 13 years, 78 +/- 10 kg) in the supine position at air volumes starting at functional residual capacity (FRC--end expiration) and increasing in 0.5 l steps to 1.5 l were studied. The averaged lung resistivity changes 12.59%, from 1406 Omega cm to 1583 Omega cm, following the inspiration of 1.5 l air from FRC. The coefficients of variation (CV) of precision for the four subjects are less than 10%. The experiment was repeated five times at each air volume on a subject to test the reproducibility. The CVs are less than 3%. The results show that it is feasible to determine absolute lung resistivity using an EIT-based method.
Torabi, Kianoosh; Rasaeipour, Sasan; Ghodsi, Safoura; Khaledi, Amir Ali Reza; Vojdani, Mahroo
2014-07-01
The exponential usage of esthetic restorative materials is beholden to society needs and desires. Interaction between the bleaching agents and the esthetic restorative materials is of critical importance. This in vitro study has been conducted to evaluate the effect of a home bleaching agent, carbamide peroxide (CP) 38%, on the microhardness of the fiber reinforced composite (FRC), overglazed, autoglazed, or polished porcelain specimens. For overglazed, autoglazed, polished ceramics and also FRC cylindrical specimens (n = 20 per group) were prepared. The specimens were stored in distilled water at 37°C for 48 hours prior to testing. Six samples from each group were selected randomly as negative controls which were stored in distilled water at 37°C that was changed daily. CP 38% was applied on the test specimens for 15 minutes, twice a day for 14 days. By using Knoop-microhardness tester microhardness testing for baseline, control and test specimens was conducted. Data were statistically analyzed using paired t-test, Mann-Whitney test, and Kruskal-Wallis test. Home bleaching significantly decreased the surface microhardness of all the test samples (p < 0.05), whereas the control groups did not show statistically significant changes after 2 weeks. The polished porcelain and polished composite specimens showed the most significant change in microhard-ness after bleaching process (p < 0.05). Although the type of surface preparation affects the susceptibility of the porcelain surface to the bleaching agent, no special preparation can preclude such adverse effects. The contact of home bleaching agents with esthetic restorative materials is unavoidable. Therefore protecting these restorations from bleaching agents and reglazing or at least polishing the restorations after bleaching is recommended.
First fast-ion D-alpha (FIDA) measurements and simulations on C-2U
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolte, N. G., E-mail: nbolte@TriAlphaEnergy.com; Gupta, D.; Onofri, M.
2016-11-15
The first measurements of fast-ion D-alpha (FIDA) radiation have been acquired on C-2U, Tri Alpha Energy’s advanced, beam-driven field-reversed configuration (FRC). These measurements are also forward modeled by FIDASIM. This is the first measurement and simulation of FIDA carried out on an FRC topology. FIDA measurements are made of Doppler-shifted Balmer-alpha light from neutralized fast ions using a bandpass filter and photomultiplier tube. One adjustable line-of-sight measured signals at eight locations and eight times during the FRC lifetime over 26 discharges. Filtered signals include only the highest energy ions (>6 keV) and share some salient features with the FIDASIM result.more » Highly Doppler-shifted beam radiation is also measured with a high-speed camera and is spatially well-correlated with FIDASIM.« less
VUV Spectra observed in C-2 FRC plasma
NASA Astrophysics Data System (ADS)
Osin, Dmitry; Douglass, Jon; Tuszewski, Michel; TAE Team
2014-10-01
A grazing incidence flat-field spectrometer was installed for observation of vuv-spectra in C-2 FRC experiment. Wavelength calibration was done by observing spectra of six different gases produced by a hollow-cathode discharge lamp . In addition, in-situ calibration and alignment were performed utilizing neutral-beam heated gases. Wavelength regions between 16 nm and 170 nm was investigated with accuracy of about 0.02 nm. VUV-spectral lines of the most abundant impurity ions were identified both for Plasma Gun and C-2 plasmas. In addition to D spectrum, strong lines of O III-VI, N IV-V, C II-III, and Fe II ions were observed during the plasma lifetime. VUV radiative power losses within energy range from 7.3 eV to 81 eV were estimated based on the calculated FRC dimensions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, M. C., E-mail: mthompson@trialphaenergy.com; Gota, H.; Putvinski, S.
The C-2U experiment at Tri Alpha Energy studies the evolution of field-reversed configuration (FRC) plasmas sustained by neutral beam injection. Data on the FRC plasma performance are provided by a comprehensive suite of diagnostics that includes magnetic sensors, interferometry, Thomson scattering, spectroscopy, bolometry, reflectometry, neutral particle analyzers, and fusion product detectors. While many of these diagnostic systems were inherited from the preceding experiment C-2, C-2U has a variety of new and upgraded diagnostic systems: multi-chord far-infrared polarimetry, multiple fast imaging cameras with selectable atomic line filters, proton detector arrays, and 100 channel bolometer units capable of observing multiple regions ofmore » the spectrum simultaneously. In addition, extensive ongoing work focuses on advanced methods of measuring separatrix shape and plasma current profile that will facilitate equilibrium reconstruction and active control of the FRC plasma.« less
Lung volume, breathing pattern and ventilation inhomogeneity in preterm and term infants.
Latzin, Philipp; Roth, Stefan; Thamrin, Cindy; Hutten, Gerard J; Pramana, Isabelle; Kuehni, Claudia E; Casaulta, Carmen; Nelle, Matthias; Riedel, Thomas; Frey, Urs
2009-01-01
Morphological changes in preterm infants with bronchopulmonary dysplasia (BPD) have functional consequences on lung volume, ventilation inhomogeneity and respiratory mechanics. Although some studies have shown lower lung volumes and increased ventilation inhomogeneity in BPD infants, conflicting results exist possibly due to differences in sedation and measurement techniques. We studied 127 infants with BPD, 58 preterm infants without BPD and 239 healthy term-born infants, at a matched post-conceptional age of 44 weeks during quiet natural sleep according to ATS/ERS standards. Lung function parameters measured were functional residual capacity (FRC) and ventilation inhomogeneity by multiple breath washout as well as tidal breathing parameters. Preterm infants with BPD had only marginally lower FRC (21.4 mL/kg) than preterm infants without BPD (23.4 mL/kg) and term-born infants (22.6 mL/kg), though there was no trend with disease severity. They also showed higher respiratory rates and lower ratios of time to peak expiratory flow and expiratory time (t(PTEF)/t(E)) than healthy preterm and term controls. These changes were related to disease severity. No differences were found for ventilation inhomogeneity. Our results suggest that preterm infants with BPD have a high capacity to maintain functional lung volume during natural sleep. The alterations in breathing pattern with disease severity may reflect presence of adaptive mechanisms to cope with the disease process.
The Fusion Gain Analysis of the Inductively Driven Liner Compression Based Fusion
NASA Astrophysics Data System (ADS)
Shimazu, Akihisa; Slough, John
2016-10-01
An analytical analysis of the fusion gain expected in the inductively driven liner compression (IDLC) based fusion is conducted to identify the fusion gain scaling at various operating conditions. The fusion based on the IDLC is a magneto-inertial fusion concept, where a Field-Reversed Configuration (FRC) plasmoid is compressed via the inductively-driven metal liner to drive the FRC to fusion conditions. In the past, an approximate scaling law for the expected fusion gain for the IDLC based fusion was obtained under the key assumptions of (1) D-T fuel at 5-40 keV, (2) adiabatic scaling laws for the FRC dynamics, (3) FRC energy dominated by the pressure balance with the edge magnetic field at the peak compression, and (4) the liner dwell time being liner final diameter divided by the peak liner velocity. In this study, various assumptions made in the previous derivation is relaxed to study the change in the fusion gain scaling from the previous result of G ml1 / 2 El11 / 8 , where ml is the liner mass and El is the peak liner kinetic energy. The implication from the modified fusion gain scaling on the performance of the IDLC fusion reactor system is also explored.
Tajiri, Sakurako; Kondo, Tetsuri; Yamabayashi, Hajime
2006-12-01
The functional residual capacity (FRC) and airway resistance (R(aw)) of the rat were measured, using a newly designed body plethysmograph (BPG), the inner environment of which was maintained at body temperature and was water-vapor saturated. The subjects were anesthetized and tracheally intubated male Wistar rats (n = 15). After measuring the FRC and R(aw), we analyzed the effects of inhaled methacholine (Mch, 0-8 mg/ml) on R(aw).The determined FRC was 5.37 +/- 0.22 ml (mean +/- SE). An almost linear relationship between box pressure and respiratory flow was obtained when the difference between box-gas temperature and the rectal temperature of the rat was less than 1.0 degrees C. The R(aw) at FRC was 0.230 +/- 0.017 cm H(2)O/ml/s. It increased proportionally with increases in the Mch concentration. When the dynamic changes in R(aw) were analyzed, the R(aw) was found to progressively increase during expiration; this increase continued throughout inspiration. Thus in the rat, R(aw) is not simply a function of changes in lung volume. In conclusion, the humidity- and temperature-adjusted BPG provided an absolute and possibly dynamic value of R(aw).
Berghofer, Y.; Klein, A.
1995-01-01
Methanococcus voltae, which contains four different gene groups that encode [NiFe]-hydrogenases, was transformed with integration vectors to achieve polar inactivation of two of the four hydrogenase operons that encode the selenium-free enzymes Vhc and Frc. Transformants which were selected by their acquired puromycin resistance showed site-specific insertions in either the vhc or frc operon by single crossover events. Southern hybridization revealed tandem integrations of whole vectors in the vhc operon, whereas only one vector copy was found in the frc operon. Northern (RNA) hybridizations showed a pac transcript of defined size, indicating strong termination in front of the hydrogenase genes downstream. In spite of the apparent abolition of expression of selenium-free hydrogenases through these polar insertions, they were not lethal to cells upon growth in selenium-deprived minimal medium, which we had previously shown to strongly induce transcription of the respective operons in M. voltae. Instead, like wild-type control cultures, transformants responded to selenium deprivation only with a reduction in growth rate. We conclude that loss of the potential to express a selenium-free hydrogenase can nevertheless be balanced by very small amounts of selenium hydrogenases under laboratory conditions in which the hydrogen supply is not likely to be a limiting growth factor. PMID:16535019
Sustainable Materials Management (SMM) Food Recovery Challenge (FRC) Data
As part of EPA's Food Recovery Challenge (FRC), organizations pledge to improve their sustainable food management practices and report their results. The FRC is part of EPA's Sustainable Materials Management Program (SMM). SMM seeks to reduce the environmental impact of materials through their entire life cycle. This includes how they are extracted, manufactured, distributed, used, reused, recycled, and disposed. Organizations are encouraged to follow the Food Recovery Hierarchy (https://www.epa.gov/sustainable-management-food/food-recovery-hierarchy) to prioritize their actions to prevent and divert wasted food. Each tier of the Food Recovery Hierarchy focuses on different management strategies for your wasted food. The program started in 2011 and the first data were made available in 2012. The FRC is part of EPA's larger SMM program (https://www.epa.gov/smm). Sustainable Materials Management (SMM) is a systemic approach to using and reusing materials more productively over their entire lifecycles. It represents a change in how our society thinks about the use of natural resources and environmental protection. By looking at a product's entire lifecycle we can find new opportunities to reduce environmental impacts, conserve resources, and reduce costs. There are multiple challenge programs available as part of the SMM program, including the Food Recovery Challenge, the Electronics Challenge, the Federal Green Challenge, and the WasteWise program.
Mechanical properties and micro-morphology of fiber posts.
Zicari, F; Coutinho, E; Scotti, R; Van Meerbeek, B; Naert, I
2013-04-01
To evaluate flexural properties of different fiber posts systems and to morphologically characterize their micro-structure. Six types of translucent fiber posts were selected: RelyX Post (3M ESPE), ParaPost Taper Lux (Colthéne-Whaledent), GC Fiber Post (GC), LuxaPost (DMG), FRC Postec Plus (Ivoclar-Vivadent), D.T. Light-Post (RTD). For each post system and size, ten specimens were subjected to a three-points bending test. Maximum fracture load, flexural strength and flexural modulus were determined using a universal loading device (5848 MicroTester(®), Instron). Besides, for each system, three intact posts of similar dimensions were processed for scanning electron microscopy to morphologically characterize the micro-structure. The following structural characteristics were analyzed: fibers/matrix ratio, density of fibers, diameter of fibers and distribution of fibers. Data were statistically analyzed with ANOVA. Type and diameter of posts were found to significantly affect the fracture load, flexural strength and flexural modulus (p<0.05). Regarding maximum fracture load, it was found to increase with post diameter, in each post system (p<0.001). Regarding flexural strength and flexural modulus, the highest values were recorded for posts with the smallest diameter (p<0.001). Finally, structural characteristics significantly varied among the post systems tested. However, any correlation has been found between flexural strength and structural characteristics. Flexural strength appeared not to be correlated to structural characteristics of fiber posts, but it may rather be affected by mechanical properties of the resin matrix and the interfacial adhesion between fibers and resin matrix. Copyright © 2013. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Bao, Jian; Lau, Calvin; Kuley, Animesh; Lin, Zhihong; Fulton, Daniel; Tajima, Toshiki; Tri Alpha Energy, Inc. Team
2017-10-01
Collisional and turbulent transport in a field reversed configuration (FRC) is studied in global particle simulation by using GTC (gyrokinetic toroidal code). The global FRC geometry is incorporated in GTC by using a field-aligned mesh in cylindrical coordinates, which enables global simulation coupling core and scrape-off layer (SOL) across the separatrix. Furthermore, fully kinetic ions are implemented in GTC to treat magnetic-null point in FRC core. Both global simulation coupling core and SOL regions and independent SOL region simulation have been carried out to study turbulence. In this work, the ``logical sheath boundary condition'' is implemented to study parallel transport in the SOL. This method helps to relax time and spatial steps without resolving electron plasma frequency and Debye length, which enables turbulent transports simulation with sheath effects. We will study collisional and turbulent SOL parallel transport with mirror geometry and sheath boundary condition in C2-W divertor.
Suppressed ion-scale turbulence in a hot high-β plasma
NASA Astrophysics Data System (ADS)
Schmitz, L.; Fulton, D. P.; Ruskov, E.; Lau, C.; Deng, B. H.; Tajima, T.; Binderbauer, M. W.; Holod, I.; Lin, Z.; Gota, H.; Tuszewski, M.; Dettrick, S. A.; Steinhauer, L. C.
2016-12-01
An economic magnetic fusion reactor favours a high ratio of plasma kinetic pressure to magnetic pressure in a well-confined, hot plasma with low thermal losses across the confining magnetic field. Field-reversed configuration (FRC) plasmas are potentially attractive as a reactor concept, achieving high plasma pressure in a simple axisymmetric geometry. Here, we show that FRC plasmas have unique, beneficial microstability properties that differ from typical regimes in toroidal confinement devices. Ion-scale fluctuations are found to be absent or strongly suppressed in the plasma core, mainly due to the large FRC ion orbits, resulting in near-classical thermal ion confinement. In the surrounding boundary layer plasma, ion- and electron-scale turbulence is observed once a critical pressure gradient is exceeded. The critical gradient increases in the presence of sheared plasma flow induced via electrostatic biasing, opening the prospect of active boundary and transport control in view of reactor requirements.
Suppressed ion-scale turbulence in a hot high-β plasma
Schmitz, L.; Fulton, D. P.; Ruskov, E.; Lau, C.; Deng, B. H.; Tajima, T.; Binderbauer, M. W.; Holod, I.; Lin, Z.; Gota, H.; Tuszewski, M.; Dettrick, S. A.; Steinhauer, L. C.
2016-01-01
An economic magnetic fusion reactor favours a high ratio of plasma kinetic pressure to magnetic pressure in a well-confined, hot plasma with low thermal losses across the confining magnetic field. Field-reversed configuration (FRC) plasmas are potentially attractive as a reactor concept, achieving high plasma pressure in a simple axisymmetric geometry. Here, we show that FRC plasmas have unique, beneficial microstability properties that differ from typical regimes in toroidal confinement devices. Ion-scale fluctuations are found to be absent or strongly suppressed in the plasma core, mainly due to the large FRC ion orbits, resulting in near-classical thermal ion confinement. In the surrounding boundary layer plasma, ion- and electron-scale turbulence is observed once a critical pressure gradient is exceeded. The critical gradient increases in the presence of sheared plasma flow induced via electrostatic biasing, opening the prospect of active boundary and transport control in view of reactor requirements. PMID:28000675
Implementing New Non-Chromate Coatings Systems (Briefing Charts)
2011-02-09
Initiate Cr6+ authorization process for continued Cr6+ use using the form, Authorization to Use Hexavalent Chromium. YES NO • Approval of...Aluminum and magnesium anodizing • Hard Chrome Plating • Type II conversion coating on aluminum alloys under chromated primer • Type II conversion coating...Elimination of Hexavalent Chromium 80% 5% 14% 1% Type II Type III Type IC Type IC Fatigue Critical 50% 50% Type II Type IC FRC-SE (JAX) Fully Integrated FRC
Spectroscopic Measurement of Ion Flow During Merging Start-up of Field-Reversed Configuration
NASA Astrophysics Data System (ADS)
Oka, Hirotaka; Inomoto, Michiaki; Tanabe, Hiroshi; Annoura, Masanobu; Ono, Yasushi; Nemoto, Koshichi
2012-10-01
The counter-helicity merging method [1] of field-reversed configuration (FRC) formation involves generation of bidirectional toroidal flow, known as a ``sling-shot.'' In two fluids regime, reconnection process is strongly affected by the Hall effect [2]. In this study, we have investigated the behavior of toroidal bidirectional flow generated by the counter-helicity merging in two-fluids regime. We use 2D Ion Doppler Spectroscopy to mesure toroidal ion flow during merging start-up of FRC from Ar gas. We defined two cases: one case with a radially pushed-in X line (case I) and the other case with a radially pushed-out X line(case O). The flow during the plasma merging shows radial asymmetry, as expected from the magnetic measurement, but finally relaxes to a unidirectional flow in plasma current direction in both cases. We observed larger toroidal flow in the plasma current direction in case I after FRC is formed, though the FRC in case O has larger magnetic flux. These results suggest that more ions are lost during merging start-up in case I. This selective ion loss might account for stability and confinement of FRCs probably maintained by high energy ions.[4pt] [1] Y. Ono, et al., Nucl. Fusion 39, pp. 2001-2008 (1999).[0pt] [2] M. Inomoto, et al., Phys. Rev. Lett., 97, 135002, (2006)
NASA Astrophysics Data System (ADS)
Smith, DuWayne L.
A Field Reversed Configuration (FRC) plasma source was designed and constructed to conduct high energy plasma-materials interaction studies. The purpose of these studies is the development of advanced materials for use in plasma based electric propulsion systems and nuclear fusion containment vessels. Outlined within this thesis is the basic concept of FRC plasmoid creation, an overview of the device design and integration of various diagnostics systems for plasma conditions and characterization, discussion on the variety of material defects resulting from the plasma exposure with methods and tools designed for characterization. Using a Michelson interferometer it was determined that the FRC plasma densities are on the order of ~1021 m-3. A novel dynamic pressure probe was created to measure ion velocities averaging 300 km/s. Compensating flux loop arrays were used to measure magnetic field strength and verify the existence of the FRC plasmoid and when used in combination with density measurements it was determined that the average ion temperatures are ~130 eV. X-ray Photoelectron Spectroscopy (XPS) was employed as a means of characterizing the size and shape of the plasma jet in the sample exposure positions. SEM results from preliminary studies reveal significant morphological changes on plasma facing material surfaces, and use of XRD to elucidate fuel gas-ion implantation strain rates correlated to plasma exposure energies.
2010-01-01
Background Corynebacterium pseudotuberculosis is generally regarded as an important animal pathogen that rarely infects humans. Clinical strains are occasionally recovered from human cases of lymphadenitis, such as C. pseudotuberculosis FRC41 that was isolated from the inguinal lymph node of a 12-year-old girl with necrotizing lymphadenitis. To detect potential virulence factors and corresponding gene-regulatory networks in this human isolate, the genome sequence of C. pseudotuberculosis FCR41 was determined by pyrosequencing and functionally annotated. Results Sequencing and assembly of the C. pseudotuberculosis FRC41 genome yielded a circular chromosome with a size of 2,337,913 bp and a mean G+C content of 52.2%. Specific gene sets associated with iron and zinc homeostasis were detected among the 2,110 predicted protein-coding regions and integrated into a gene-regulatory network that is linked with both the central metabolism and the oxidative stress response of FRC41. Two gene clusters encode proteins involved in the sortase-mediated polymerization of adhesive pili that can probably mediate the adherence to host tissue to facilitate additional ligand-receptor interactions and the delivery of virulence factors. The prominent virulence factors phospholipase D (Pld) and corynebacterial protease CP40 are encoded in the genome of this human isolate. The genome annotation revealed additional serine proteases, neuraminidase H, nitric oxide reductase, an invasion-associated protein, and acyl-CoA carboxylase subunits involved in mycolic acid biosynthesis as potential virulence factors. The cAMP-sensing transcription regulator GlxR plays a key role in controlling the expression of several genes contributing to virulence. Conclusion The functional data deduced from the genome sequencing and the extended knowledge of virulence factors indicate that the human isolate C. pseudotuberculosis FRC41 is equipped with a distinct gene set promoting its survival under unfavorable environmental conditions encountered in the mammalian host. PMID:21192786
Simplifying the assessment of coronary artery stenosis by enhancing instantaneous wave free ratio.
Spagnoli, Vincent; Picard, Fabien; Tadros, Victor-Xavier; Cournoyer, Daniel; Doucet, Serge; Tanguay, Jean François; Gosselin, Gilbert; de Guise, Pierre; Gallo, Richard
2018-04-01
Instantaneous wave free ratio (iFR) does not require adenosine, but has a relatively wide intermediate range where functional assessment remains inconclusive. In this pilot study, we sought to enhance iFR through with the use of intracoronary (IC) saline (iFRs) and contrast media (iFRc) and determine whether these techniques correlated well with fractional flow reserve (FFR). Patients with coronary artery stenosis (CAS) associated with an iFR in the intermediate zone (≥0.86 and ≤0.93) were prospectively assessed with resting distal coronary pressure/aorta pressure (Pd/Pa), iFR, iFRs, iFRc and FFR. A total of 40 coronary lesions were studied (40 patients). Pearson correlation coefficients for FFR and iFR, FFR and iFRs, FFR and iFRc were respectively: 0.57 (P=0.0002), 0.80 (P<0.0001) and 0.77 (P<0.0001). Receiver-operating characteristic (ROC) curve analysis showed similar area under the curve (AUC) of iFRs and iFR [0.90 (95% CI: 0.76-1) vs. 0.89 (95% CI: 0.79-0.99), P=0.89]. Youden's index established cut-off values of ≤0.90 for iFR (sensitivity =91%, specificity =74%) and ≤0.78 for iFRs (sensitivity =73%, specificity =100%). In contrast, the AUC of iFRc was superior to the AUC of iFR [0.99 (95% CI: 0.98-1), P=0.049]. iFRc showed excellent accuracy and established cut-off values of ≤0.81 in predicting an FFR value of ≤0.80 (sensitivity =100%, specificity =93%). When iFR is in the intermediate zone, functional assessment of CAS by iFR is enhanced with the use of contrast media but not saline. This pilot study could be hypothesis generating for further study to enhance iFR specificity and sensibility.
Simplifying the assessment of coronary artery stenosis by enhancing instantaneous wave free ratio
Spagnoli, Vincent; Picard, Fabien; Tadros, Victor-Xavier; Cournoyer, Daniel; Doucet, Serge; Tanguay, Jean François; Gosselin, Gilbert; de Guise, Pierre
2018-01-01
Background Instantaneous wave free ratio (iFR) does not require adenosine, but has a relatively wide intermediate range where functional assessment remains inconclusive. In this pilot study, we sought to enhance iFR through with the use of intracoronary (IC) saline (iFRs) and contrast media (iFRc) and determine whether these techniques correlated well with fractional flow reserve (FFR). Methods Patients with coronary artery stenosis (CAS) associated with an iFR in the intermediate zone (≥0.86 and ≤0.93) were prospectively assessed with resting distal coronary pressure/aorta pressure (Pd/Pa), iFR, iFRs, iFRc and FFR. Results A total of 40 coronary lesions were studied (40 patients). Pearson correlation coefficients for FFR and iFR, FFR and iFRs, FFR and iFRc were respectively: 0.57 (P=0.0002), 0.80 (P<0.0001) and 0.77 (P<0.0001). Receiver-operating characteristic (ROC) curve analysis showed similar area under the curve (AUC) of iFRs and iFR [0.90 (95% CI: 0.76–1) vs. 0.89 (95% CI: 0.79–0.99), P=0.89]. Youden’s index established cut-off values of ≤0.90 for iFR (sensitivity =91%, specificity =74%) and ≤0.78 for iFRs (sensitivity =73%, specificity =100%). In contrast, the AUC of iFRc was superior to the AUC of iFR [0.99 (95% CI: 0.98–1), P=0.049]. iFRc showed excellent accuracy and established cut-off values of ≤0.81 in predicting an FFR value of ≤0.80 (sensitivity =100%, specificity =93%). Conclusions When iFR is in the intermediate zone, functional assessment of CAS by iFR is enhanced with the use of contrast media but not saline. This pilot study could be hypothesis generating for further study to enhance iFR specificity and sensibility. PMID:29850406
Rowe, Annette R; Mansfeldt, Cresten B; Heavner, Gretchen L; Richardson, Ruth E
2013-01-02
Molecular biomarkers hold promise for inferring rates of key metabolic activities in complex microbial systems. However, few studies have assessed biomarker levels for simultaneously occurring (and potentially competing) respirations. In this study, methanogenesis biomarkers for Methanospirillum hungatei were developed, tested, and compared to Dehalococcoides mccartyi biomarkers in a well-characterized mixed culture. Proteomic analyses of mixed culture samples (n = 4) confirmed expression of many M. hungatei methanogenesis enzymes. The mRNAs for two oxidoreductases detected were explored as quantitative biomarkers of hydrogenotrophic methanogenesis: a coenzyme F(420)-reducing hydrogenase (FrcA) and an iron sulfur protein (MvrD). As shown previously in D. mccartyi, M. hungatei transcript levels correlated linearly with measured (R = 0.97 for FrcA, R = 0.91 for MvrD; n = 7) or calculated respiration rate (R = 0.81 for FrcA, R = 0.62 for MvrD; n = 35) across two orders of magnitude on a log-log scale. The average abundance of MvrD transcripts was consistently two orders of magnitude lower than FrcA, regardless of experimental condition. In experiments where M. hungatei was competing for hydrogen with D. mccartyi, transcripts for the key respiratory hydrogenase HupL were generally less abundant per mL than FrcA and more abundant than MvrD. With no chlorinated electron acceptor added, HupL transcripts fell below both targets. These biomarkers hold promise for the prediction of in situ rates of respiration for these microbes, even when growing in mixed culture and utilizing a shared substrate which has important implications for both engineered and environmental systems. However, the differences in overall biomarker abundances suggest that the strength of any particular mRNA biomarker relies upon empirically established quantitative trends under a range of pertinent conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slough, John
The entry of fusion as a viable, competitive source of power has been stymied by the challenge of finding an economical way to provide for the confinement and heating of the plasma fuel. The main impediment for current nuclear fusion concepts is the complexity and large mass associated with the confinement systems. To take advantage of the smaller scale, higher density regime of magnetic fusion, an efficient method for achieving the compressional heating required to reach fusion gain conditions must be found. The very compact, high energy density plasmoid commonly referred to as a Field Reversed Configuration (FRC) provides formore » an ideal target for this purpose. To make fusion with the FRC practical, an efficient method for repetitively compressing the FRC to fusion gain conditions is required. A novel approach to be explored in this endeavor is to remotely launch a converging array of small macro-particles (macrons) that merge and form a more massive liner inside the reactor which then radially compresses and heats the FRC plasmoid to fusion conditions. The closed magnetic field in the target FRC plasmoid suppresses the thermal transport to the confining liner significantly lowering the imploding power needed to compress the target. With the momentum flux being delivered by an assemblage of low mass, but high velocity macrons, many of the difficulties encountered with the liner implosion power technology are eliminated. The undertaking to be described in this proposal is to evaluate the feasibility achieving fusion conditions from this simple and low cost approach to fusion. During phase I the design and testing of the key components for the creation of the macron formed liner have been successfully carried out. Detailed numerical calculations of the merging, formation and radial implosion of the Macron Formed Liner (MFL) were also performed. The phase II effort will focus on an experimental demonstration of the macron launcher at full power, and the demonstration of megagauss magnetic field compression by a small array of full scale macrons. In addition the physics of the compression of an FRC to fusion conditions will be undertaken with a smaller scale MFL. The timescale for testing will be rapidly accelerated by taking advantage of other facilities at MSNW where the target FRC will be created and translated inside the MFL just prior to implosion of the MFL. Experimental success would establish the concept at the proof of principle level and the following phase III effort would focus on the full development of the concept into a fusion gain device. Successful operation would lead to several benefits in various fields. It would have application to high energy density physics, as well as nuclear waste transmutation and alternate fission fuel cycles. The smaller scale device could find immediate application as an intense source of neutrons for diagnostic imaging and non-invasive object interrogation.« less
Hall effect on a Merging Formation Process of a Field-Reversed Configuration
NASA Astrophysics Data System (ADS)
Kaminou, Yasuhiro; Guo, Xuehan; Inomoto, Michiaki; Ono, Yasushi; Horiuchi, Ritoku
2015-11-01
Counter-helicity spheromak merging is one of the formation methods of a Field-Reversed Configuration (FRC). In counter-helicity spheromak merging, two spheromaks with opposing toroidal fields merge together, through magnetic reconnection events and relax into a FRC, which has no or little toroidal field. This process contains magnetic reconnection and a relaxation phenomena, and the Hall effect has some essential effects on these process because the X-point in the magnetic reconnection or the O-point of the FRC has no or little magnetic field. However, the Hall effect as both global and local effect on counter-helicity spheromak merging has not been elucidated. In this poster, we conducted 2D/3D Hall-MHD simulations and experiments of counter-helicity spheromak merging. We find that the Hall effect enhances the reconnection rate, and reduces the generation of toroidal sheared-flow. The suppression of the ``slingshot effect'' affects the relaxation process. We will discuss details in the poster.
Simulation of drift wave instability in field-reversed configurations using global magnetic geometry
NASA Astrophysics Data System (ADS)
Fulton, D. P.; Lau, C. K.; Lin, Z.; Tajima, T.; Holod, I.; the TAE Team
2016-10-01
Minimizing transport in the field-reversed configuration (FRC) is essential to enable FRC-based fusion reactors. Recently, significant progress on advanced beam-driven FRCs in C-2 and C-2U (at Tri Alpha Energy) provides opportunities to study transport properties using Doppler backscattering (DBS) measurements of turbulent fluctuations and kinetic particle-in-cell simulations of driftwaves in realistic equilibria via the Gyrokinetic Toroidal Code (GTC). Both measurements and simulations indicate relatively small fluctuations in the scrape-off layer (SOL). In the FRC core, local, single flux surface simulations reveal strong stabilization, while experiments indicate quiescent but finite fluctuations. One possible explanation is that turbulence may originate in the SOL and propagate at very low levels across the separatrix into the core. To test this hypothesis, a significant effort has been made to develop A New Code (ANC) based on GTC physics formulations, but using cylindrical coordinates which span the magnetic separatrix, including both core and SOL. Here, we present first results from global ANC simulations.
Kentgens, Anne-Christianne; Guidi, Marisa; Korten, Insa; Kohler, Lena; Binggeli, Severin; Singer, Florian; Latzin, Philipp; Anagnostopoulou, Pinelopi
2018-05-01
Multiple breath washout (MBW) is a sensitive test to measure lung volumes and ventilation inhomogeneity from infancy on. The commonly used setup for infant MBW, based on ultrasonic flowmeter, requires extensive signal processing, which may reduce robustness. A new setup may overcome some previous limitations but formal validation is lacking. We assessed the feasibility of infant MBW testing with the new setup and compared functional residual capacity (FRC) values of the old and the new setup in vivo and in vitro. We performed MBW in four healthy infants and four infants with cystic fibrosis, as well as in a Plexiglas lung simulator using realistic lung volumes and breathing patterns, with the new (Exhalyzer D, Spiroware 3.2.0, Ecomedics) and the old setup (Exhalyzer D, WBreath 3.18.0, ndd) in random sequence. The technical feasibility of MBW with the new device-setup was 100%. Intra-subject variability in FRC was low in both setups, but differences in FRC between the setups were considerable (mean relative difference 39.7%, range 18.9; 65.7, P = 0.008). Corrections of software settings decreased FRC differences (14.0%, -6.4; 42.3, P = 0.08). Results were confirmed in vitro. MBW measurements with the new setup were feasible in infants. However, despite attempts to correct software settings, outcomes between setups were not interchangeable. Further work is needed before widespread application of the new setup can be recommended. © 2018 Wiley Periodicals, Inc.
Palmitate Attenuates Osteoblast Differentiation of Fetal Rat Calvarial Cells
Yeh, Lee-Chuan C.; Ford, Jeffery J.; Lee, John C.; Adamo, Martin L.
2014-01-01
Aging is associated with the accumulation of ectopic lipid resulting in the inhibition of normal organ function, a phenomenon known as lipotoxicity. Within the bone marrow microenvironment, elevation in fatty acid levels may produce an increase in osteoclast activity and a decrease in osteoblast number and function, thus contributing to age-related osteoporosis. However, little is known about lipotoxic mechanisms in intramembraneous bone. Previously we reported that the long chain saturated fatty acid palmitate inhibited the expression of the osteogenic markers RUNX2 and osteocalcin in fetal rat calvarial cell (FRC) cultures. Moreover, the acetyl Co-A carboxylase inhibitor TOFA blocked the inhibitory effect of palmitate on expression of these two markers. In the current study we have extended these observations to show that palmitate inhibits spontaneous mineralized bone formation in FRC cultures in association with reduced mRNA expression of RUNX2, alkaline phosphatase, osteocalcin, and bone sialoprotein and reduced alkaline phosphatase activity. The effects of palmitate on osteogenic marker expression were inhibited by TOFA. Palmitate also inhibited the mRNA expression of fatty acid synthase and PPAR gamma in FRC cultures, and as with osteogenic markers, this effect was inhibited by TOFA. Palmitate had no effect on FRC cell proliferation or apoptosis, but inhibited BMP-7-induced alkaline phosphatase activity. We conclude that palmitate accumulation may lead to lipotoxic effects on osteoblast differentiation and mineralization and that increases in fatty acid oxidation may help to prevent these lipotoxic effects. PMID:24955854
Palmitate attenuates osteoblast differentiation of fetal rat calvarial cells.
Yeh, Lee-Chuan C; Ford, Jeffery J; Lee, John C; Adamo, Martin L
2014-07-18
Aging is associated with the accumulation of ectopic lipid resulting in the inhibition of normal organ function, a phenomenon known as lipotoxicity. Within the bone marrow microenvironment, elevation in fatty acid levels may produce an increase in osteoclast activity and a decrease in osteoblast number and function, thus contributing to age-related osteoporosis. However, little is known about lipotoxic mechanisms in intramembraneous bone. Previously we reported that the long chain saturated fatty acid palmitate inhibited the expression of the osteogenic markers RUNX2 and osteocalcin in fetal rat calvarial cell (FRC) cultures. Moreover, the acetyl CoA carboxylase inhibitor TOFA blocked the inhibitory effect of palmitate on expression of these two markers. In the current study we have extended these observations to show that palmitate inhibits spontaneous mineralized bone formation in FRC cultures in association with reduced mRNA expression of RUNX2, alkaline phosphatase, osteocalcin, and bone sialoprotein and reduced alkaline phosphatase activity. The effects of palmitate on osteogenic marker expression were inhibited by TOFA. Palmitate also inhibited the mRNA expression of fatty acid synthase and PPARγ in FRC cultures, and as with osteogenic markers, this effect was inhibited by TOFA. Palmitate had no effect on FRC cell proliferation or apoptosis, but inhibited BMP-7-induced alkaline phosphatase activity. We conclude that palmitate accumulation may lead to lipotoxic effects on osteoblast differentiation and mineralization and that increases in fatty acid oxidation may help to prevent these lipotoxic effects. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nour, Ali, E-mail: ali.nour@polymtl.ca; Hydro Quebec, Montreal, Quebec, H2L 4P5; Massicotte, Bruno
This study is aimed at proposing a simple analytical model to investigate the post-cracking behaviour of FRC panels, using an arbitrary tension softening, stress crack opening diagram, as the input. A new relationship that links the crack opening to the panel deflection is proposed. Due to the stochastic nature of material properties, the random fibre distribution, and other uncertainties that are involved in concrete mix, this relationship is developed from the analysis of beams having the same thickness using the Monte Carlo simulation (MCS) technique. The softening diagrams obtained from direct tensile tests are used as the input for themore » calculation, in a deterministic way, of the mean load displacement response of round panels. A good agreement is found between the model predictions and the experimental results.« less
2010-10-01
of tensile yield strength (Fty) and the runout load (107 cycles), with no more than four points per load. Load and cycles to failure were used to...were coated with 0.002” nCo-P at Integran Technologies Inc. or 0.002” at FRC-SE. Testing was conducted using CS-17 wheels at FRC-SE. 3.2 RESULTS...Abrasive wear tests shall be conducted using the Taber wear test apparatus in accordance with ASTM D4060 using a CS-17 wheel . The wear rate of
NASA Astrophysics Data System (ADS)
Joshi, Akshay; Mangal, R.; Bhojak, N.
2018-05-01
Ziziphus is the one of the most abundant plant of arid region of Rajasthan and rest part of desert land in world. There are a lots of research work going on and has been done on medical applications of this plant and it is playing very important role in economy of desert areas. In this paper our discussion will bring the attention its physical properties so that we can find the possibility of its applications in the various field of fiber reinforced composites which either can be used in such as interior & exterior part of automotive so it can reduce their overall weight, cost and improve its fuel efficiency without compromising in strength or can be used in flywheel technology for energy saving in automobiles or in building materials and so on. In this paper our approach is to extract the fiber from this plant, analyze the mechanical properties of the fiber and then discuss the various possibility of its application in appropriate field of composites. To find the possibility in FRC for Ziziphus fiber our next step is to compare it with other fibers whose composites have already been formed and studied.
Resolution Versus Error for Computational Electron Microscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luzi, Lorenzo; Stevens, Andrew; Yang, Hao
Images that are collected via scanning transmission electron microscopy (STEM) can be undersampled to avoid damage to the specimen while maintaining resolution [1, 2]. We have used BPFA to impute missing data and reduce noise [3]. The reconstruction is typically evaluated using the peak signal-to-noise ratio (PSNR). This measure is too conservative for STEM images and we propose that the Fourier ring correlation (FRC) is used instead to evaluate the reconstruction. We are not concerned with exact reconstruction of the truth image, and therefore PSNR is a conservative estimation of the quality of the reconstruction. Instead, we are concerned withmore » the visual resolution of the image and whether atoms can be distinguished. We have evaluated the reconstruction of a simulated STEM image using the FRC and compared the results with the PSNR measurements. The FRC captures the resolution of the image and is not affected by a large MSE if the atom peaks are still distinguishable. The noisy and reconstructed images are shown in Figure 1. The simulated STEM image was sampled at 100%, 80%, 40%, and 20% of the original pixels to simulate an undersampled scan. The reconstruction was done using BPFA with a patch size of 10 x 10 and no overlapping patches. Not having overlapping patches produces inferior results but they are still acceptable. The dictionary size is 64 and 30 iterations were completed during each reconstruction. The 100% image was denoised instead of reconstructed. Poisson noise was applied to the simulated image with λ values of 500, 50, and 5 to simulate lower imaging dose. The original simulated STEM image was also included in our calculations and was generated using a dose of 1000. The simulated STEM image is 100 by 100 pixels and has essentially no high frequency components. The image reconstruction tends to smooth the data, also resulting in no high frequency components. This causes the FRC of the two images to be large at higher resolutions and may be misleading. For this reason, the BPFA has no overlap to avoid excessive smoothing. Moreover, the resolution of the simulated image is approximately 9.2 (1/nm), so we only look that far in the frequency domain when performing FRC. If the FRC curve does not crossover the threshold, a resolution value of 9.2 is used. We emphasize that our reported results are conservative. The FRC and PSNR values using the ground truth and the reconstructed images are shown in Tables 1 and 2. The left side show the metrics without using BPFA (missing pixels) and the right side show the metrics after using BPFA. When we did not use BPFA, the Fourier transform was estimated [4]. Some threshold curves have been studied [5], but they are derived for additive noise models. Since we have a Poisson noise model, we have used the more conservative threshold of 0.5 for our calculations. Ten images were used to construct each cell of tables in the form of the mean of the metric plus or minus its standard deviation. As expected, the PSNR dies off much quicker than the FRC values for the same image. For the 100% and 80% sampled versions of the truth image, the resolution only dies off when the dose is 5. However, the PSNR dies off rapidly as the dose is reduced. For the 1000, 500, and 50 dose images, the FRC is the maximum, or close, until we undersample at 20%. The PSNR for these values tapers down as we get into the bottom right hand corner of the table, even though the resolution remains high. Overall, we find that undersampled images can be reconstructed to acceptable resolution even when the dose per pixel is also reduced[6]. References: [1]A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2]A Stevens, L Kovarik, P Abellan et al. Advanced Structural and Chemical Imaging 1(1), (2015), pp. 1. [3]M Zhou, H Chen, J Paisley et al. Image Processing, IEEE Transactions on 21(1), (2012), pp. 130. [4]V. Y. Liepin’sh. Automatic control and computer sciences 30(3), (1996), pp. 20.« less
Kinetic simulation of edge instability in fusion plasmas
NASA Astrophysics Data System (ADS)
Fulton, Daniel Patrick
In this work, gyrokinetic simulations in edge plasmas of both tokamaks and field reversed. configurations (FRC) have been carried out using the Gyrokinetic Toroidal Code (GTC) and A New Code (ANC) has been formulated for cross-separatrix FRC simulation. In the tokamak edge, turbulent transport in the pedestal of an H-mode DIII-D plasma is. studied via simulations of electrostatic driftwaves. Annulus geometry is used and simulations focus on two radial locations corresponding to the pedestal top with mild pressure gradient and steep pressure gradient. A reactive trapped electron instability with typical ballooning mode structure is excited in the pedestal top. At the steep gradient, the electrostatic instability exhibits unusual mode structure, peaking at poloidal angles theta=+- pi/2. Simulations find this unusual mode structure is due to steep pressure gradients in the pedestal but not due to the particular DIII-D magnetic geometry. Realistic DIII-D geometry has a stabilizing effect compared to a simple circular tokamak geometry. Driftwave instability in FRC is studied for the first time using gyrokinetic simulation. GTC. is upgraded to treat realistic equilibrium calculated by an MHD equilibrium code. Electrostatic local simulations in outer closed flux surfaces find ion-scale modes are stable due to the large ion gyroradius and that electron drift-interchange modes are excited by electron temperature gradient and bad magnetic curvature. In the scrape-off layer (SOL) ion-scale modes are excited by density gradient and bad curvature. Collisions have weak effects on instabilities both in the core and SOL. Simulation results are consistent with density fluctuation measurements in the C-2 experiment using Doppler backscattering (DBS). The critical density gradients measured by the DBS qualitatively agree with the linear instability threshold calculated by GTC simulations. One outstanding critical issue in the FRC is the interplay between turbulence in the FRC. core and SOL regions. While the magnetic flux coordinates used by GTC provide a number of computational advantages, they present unique challenges at the magnetic field separatrix. To address this limitation, a new code, capable of coupled core-SOL simulations, is formulated, implemented, and successfully verified.
Santana, Pauliane Vieira; Prina, Elena; Albuquerque, André Luis Pereira; Carvalho, Carlos Roberto Ribeiro; Caruso, Pedro
2016-01-01
Objective: To investigate the applicability of ultrasound imaging of the diaphragm in interstitial lung disease (ILD). Methods: Using ultrasound, we compared ILD patients and healthy volunteers (controls) in terms of diaphragmatic mobility during quiet and deep breathing; diaphragm thickness at functional residual capacity (FRC) and at total lung capacity (TLC); and the thickening fraction (TF, proportional diaphragm thickening from FRC to TLC). We also evaluated correlations between diaphragmatic dysfunction and lung function variables. Results: Between the ILD patients (n = 40) and the controls (n = 16), mean diaphragmatic mobility was comparable during quiet breathing, although it was significantly lower in the patients during deep breathing (4.5 ± 1.7 cm vs. 7.6 ± 1.4 cm; p < 0.01). The patients showed greater diaphragm thickness at FRC (p = 0.05), although, due to lower diaphragm thickness at TLC, they also showed a lower TF (p < 0.01). The FVC as a percentage of the predicted value (FVC%) correlated with diaphragmatic mobility (r = 0.73; p < 0.01), and an FVC% cut-off value of < 60% presented high sensitivity (92%) and specificity (81%) for indentifying decreased diaphragmatic mobility. Conclusions: Using ultrasound, we were able to show that diaphragmatic mobility and the TF were lower in ILD patients than in healthy controls, despite the greater diaphragm thickness at FRC in the former. Diaphragmatic mobility correlated with ILD functional severity, and an FVC% cut-off value of < 60% was found to be highly accurate for indentifying diaphragmatic dysfunction on ultrasound. PMID:27167428
Come, Carolyn E; Diaz, Alejandro A; Curran-Everett, Douglas; Muralidhar, Nivedita; Hersh, Craig P; Zach, Jordan A; Schroeder, Joyce; Lynch, David A; Celli, Bartolome; Washko, George R
2013-06-01
CT scanning is increasingly used to characterize COPD. Although it is possible to obtain CT scan-measured lung lobe volumes, normal ranges remain unknown. Using COPDGene data, we developed reference equations for lobar volumes at maximal inflation (total lung capacity [TLC]) and relaxed exhalation (approximating functional residual capacity [FRC]). Linear regression was used to develop race-specific (non-Hispanic white [NHW], African American) reference equations for lobar volumes. Covariates included height and sex. Models were developed in a derivation cohort of 469 subjects with normal pulmonary function and validated in 546 similar subjects. These cohorts were combined to produce final prediction equations, which were applied to 2,191 subjects with old GOLD (Global Initiative for Chronic Obstructive Lung Disease) stage II to IV COPD. In the derivation cohort, women had smaller lobar volumes than men. Height positively correlated with lobar volumes. Adjusting for height, NHWs had larger total lung and lobar volumes at TLC than African Americans; at FRC, NHWs only had larger lower lobes. Age and weight had no effect on lobar volumes at TLC but had small effects at FRC. In subjects with COPD at TLC, upper lobes exceeded 100% of predicted values in GOLD II disease; lower lobes were only inflated to this degree in subjects with GOLD IV disease. At FRC, gas trapping was severe irrespective of disease severity and appeared uniform across the lobes. Reference equations for lobar volumes may be useful in assessing regional lung dysfunction and how it changes in response to pharmacologic therapies and surgical or endoscopic lung volume reduction.
Toyota, Cory G.; Berthold, Catrine L.; Gruez, Arnaud; Jónsson, Stefán; Lindqvist, Ylva; Cambillau, Christian; Richards, Nigel G. J.
2008-01-01
The yfdXWUVE operon appears to encode proteins that enhance the ability of Escherichia coli MG1655 to survive under acidic conditions. Although the molecular mechanisms underlying this phenotypic behavior remain to be elucidated, findings from structural genomic studies have shown that the structure of YfdW, the protein encoded by the yfdW gene, is homologous to that of the enzyme that mediates oxalate catabolism in the obligate anaerobe Oxalobacter formigenes, O. formigenes formyl coenzyme A transferase (FRC). We now report the first detailed examination of the steady-state kinetic behavior and substrate specificity of recombinant, wild-type YfdW. Our studies confirm that YfdW is a formyl coenzyme A (formyl-CoA) transferase, and YfdW appears to be more stringent than the corresponding enzyme (FRC) in Oxalobacter in employing formyl-CoA and oxalate as substrates. We also report the effects of replacing Trp-48 in the FRC active site with the glutamine residue that occupies an equivalent position in the E. coli protein. The results of these experiments show that Trp-48 precludes oxalate binding to a site that mediates substrate inhibition for YfdW. In addition, the replacement of Trp-48 by Gln-48 yields an FRC variant for which oxalate-dependent substrate inhibition is modified to resemble that seen for YfdW. Our findings illustrate the utility of structural homology in assigning enzyme function and raise the question of whether oxalate catabolism takes place in E. coli upon the up-regulation of the yfdXWUVE operon under acidic conditions. PMID:18245280
Bruce, Kimberley; Lawler, Clara; Cardin, Rhonda D.
2016-01-01
Cytomegaloviruses (CMVs) establish chronic, systemic infections. Peripheral infection spreads via lymph nodes, which are also a focus of host defence. Thus, this is a point at which systemic infection spread might be restricted. Subcapsular sinus macrophages (SSM) captured murine CMV (MCMV) from the afferent lymph and poorly supported its replication. Blocking the type I interferon (IFN-I) receptor (IFNAR) increased MCMV infection of SSM and of the fibroblastic reticular cells (FRC) lining the subcapsular sinus, and accelerated viral spread to the spleen. Little splenic virus derived from SSM, arguing that they mainly induce an anti-viral state in the otherwise susceptible FRC. NK cells also limited infection, killing infected FRC and causing tissue damage. They acted independently of IFN-I, as IFNAR blockade increased NK cell recruitment, and NK cell depletion increased infection in IFNAR-blocked mice. Thus SSM restricted MCMV infection primarily though IFN-I, with NK cells providing a second line of defence. The capacity of innate immunity to restrict MCMV escape from the subcapsular sinus suggested that enhancing its recruitment might improve infection control. PMID:27926941
Recent breakthroughs on C-2U: Norman’s legacy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Binderbauer, M. W.; Tajima, T.; Tuszewski, M.
Conventional field-reversed configurations (FRC) face notable stability and confinement concerns, which can be ameliorated by introducing and maintaining a significant fast ion population in the system. This is the conjecture first introduced by Norman Rostoker multiple decades ago and adopted as the central design tenet in Tri Alpha Energy’s advanced beam driven FRC concept. In fact, studying the physics of such neutral beam (NB) driven FRCs over the past decade, considerable improvements were made in confinement and stability. Next to NB injection, the addition of axially streaming plasma guns, magnetic end plugs, as well as advanced surface conditioning lead tomore » dramatic reductions in turbulence driven losses and greatly improved stability. In turn, fast ion confinement improved significantly and allowed for the build-up of a dominant fast particle population. This recently led to the breakthrough of sustaining an advanced beam driven FRC, thereby demonstrating successful maintenance of trapped magnetic flux, plasma dimensions and total pressure inventory for times much longer than all characteristic system time scales and only limited by hardware and electric supply constraints.« less
A Pre-ionization System to Limit Neutral Gas in a Compact Toroid Injector
NASA Astrophysics Data System (ADS)
Allfrey, Ian; Roche, Thomas; Matsumoto, Tadafumi; Garate, Eusebio; Gota, Hiroshi; Asai, Tomohiko; the TAE Team
2016-10-01
Fusion plasmas require long lifetimes and high temperatures, both of which are limited by particle loss, among other factors. Therefore, refueling a long-lived advanced beam-driven field-reversed configuration (FRC) plasma in C-2U is necessary, and injecting a supersonic compact toroid (CT) is an effective means of introducing particles into the FRC core. However, neutral gas that trails the CT into the target chamber cools the FRC. Pre-ionization (PI) system assists the break down between electrodes of the CT injector (CTI), so the amount of introduced gas can be lowered by up to a factor of two, effectively increasing the ionization fraction; thus, reducing the amount of neutral gas in the system. Additionally, the PI decreases the delay in CTI breakdown so a highly reproducible operation is achievable. The PI system consists of a fast, high voltage, pulse discharge circuit coupled to a Teflon insulated semi-rigid coaxial cable inserted into the CTI. System details and experimental data will be presented, in addition to issues such as the introduction of impurities and pre-ionizer lifetime.
Transport studies in high-performance field reversed configuration plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupta, S., E-mail: sgupta@trialphaenergy.com; Barnes, D. C.; Dettrick, S. A.
2016-05-15
A significant improvement of field reversed configuration (FRC) lifetime and plasma confinement times in the C-2 plasma, called High Performance FRC regime, has been observed with neutral beam injection (NBI), improved edge stability, and better wall conditioning [Binderbauer et al., Phys. Plasmas 22, 056110 (2015)]. A Quasi-1D (Q1D) fluid transport code has been developed and employed to carry out transport analysis of such C-2 plasma conditions. The Q1D code is coupled to a Monte-Carlo code to incorporate the effect of fast ions, due to NBI, on the background FRC plasma. Numerically, the Q1D transport behavior with enhanced transport coefficients (butmore » with otherwise classical parametric dependencies) such as 5 times classical resistive diffusion, classical thermal ion conductivity, 20 times classical electron thermal conductivity, and classical fast ion behavior fit with the experimentally measured time evolution of the excluded flux radius, line-integrated density, and electron/ion temperature. The numerical study shows near sustainment of poloidal flux for nearly 1 ms in the presence of NBI.« less
Lung volumes during sustained microgravity on Spacelab SLS-1
NASA Technical Reports Server (NTRS)
Elliott, Ann R.; Prisk, Gordon Kim; Guy, Harold J. B.; West, John B.
1994-01-01
Gravity is known to influence the topographical gradients of pulmonary ventilation, perfusion, and pleural pressures. The effect of sustained microgravity on lung volumes has not previously been investigated. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box and flowmeter system and a respiratory mass spectrometer. Measurements of tidal volume (V(sub T)), expiratory reserve volume (ERV), inspiratory and expiratory vital capacities (IVC, EVC), functional residual capacity (FRC), and residual volume (RV) were made. During microgravity, V(sub T) decreased by 15%. IVC and EVC were slightly reduced during the first 24 hrs of microgravity and returned to 1 g standing values within 72 hrs after the onset of microgravity. FRC was reduced by 15% and ERV decreased by 10-20%. RV was significantly reduced by 18%. The reductions in FRC, ERV, and V(sub T) during microgravity are probably due to the cranial shift of the diaphragm and an increase in intrathoracic blood volume.
Tissue Engineering of Cartilage on Ground-Based Facilities
NASA Astrophysics Data System (ADS)
Aleshcheva, Ganna; Bauer, Johann; Hemmersbach, Ruth; Egli, Marcel; Wehland, Markus; Grimm, Daniela
2016-06-01
Investigations under simulated microgravity offer the opportunity for a better understanding of the influence of altered gravity on cells and the scaffold-free three-dimensional (3D) tissue formation. To investigate the short-term influence, human chondrocytes were cultivated for 2 h, 4 h, 16 h, and 24 h on a 2D Fast-Rotating Clinostat (FRC) in DMEM/F-12 medium supplemented with 10 % FCS. We detected holes in the vimentin network, perinuclear accumulations of vimentin after 2 h, and changes in the chondrocytes shape visualised by F-actin staining after 4 h of FRC-exposure. Scaffold-free cultivation of chondrocytes for 7 d on the Random Positioning Machine (RPM), the FRC and the Rotating Wall Vessel (RWV) resulted in spheroid formation, a phenomenon already known from spaceflight experiments with chondrocytes (MIR Space Station) and thyroid cancer cells (SimBox/Shenzhou-8 space mission). The experiments enabled by the ESA-CORA-GBF programme gave us an optimal opportunity to study gravity-related cellular processes, validate ground-based facilities for our chosen cell system, and prepare long-term experiments under real microgravity conditions in space
Whole Device Modeling of Compact Tori: Stability and Transport Modeling of C-2W
NASA Astrophysics Data System (ADS)
Dettrick, Sean; Fulton, Daniel; Lau, Calvin; Lin, Zhihong; Ceccherini, Francesco; Galeotti, Laura; Gupta, Sangeeta; Onofri, Marco; Tajima, Toshiki; TAE Team
2017-10-01
Recent experimental evidence from the C-2U FRC experiment shows that the confinement of energy improves with inverse collisionality, similar to other high beta toroidal devices, NSTX and MAST. This motivated the construction of a new FRC experiment, C-2W, to study the energy confinement scaling at higher electron temperature. Tri Alpha Energy is working towards catalysing a community-wide collaboration to develop a Whole Device Model (WDM) of Compact Tori. One application of the WDM is the study of stability and transport properties of C-2W using two particle-in-cell codes, ANC and FPIC. These codes can be used to find new stable operating points, and to make predictions of the turbulent transport at those points. They will be used in collaboration with the C-2W experimental program to validate the codes against C-2W, mitigate experimental risk inherent in the exploration of new parameter regimes, accelerate the optimization of experimental operating scenarios, and to find operating points for future FRC reactor designs.
Fragmented red cells reference range for the Sysmex XN®-series of automated blood cell counters.
Lesesve, J-F; Speyer, E; Perol, J-P
2015-10-01
Fragmented red cells (FRCs) are a new parameter determined automatically by the latest generation of blood cell counters. FRC counts may be of interest as they may reflect schistocyte counts measured on a stained peripheral blood smear observed under the microscope. However, FRC counts depend on the technical procedure used to detect them so that reference ranges are device dependent. The XN-9000® is one of the latest models from the Sysmex series of analysers. We aimed to establish a reference range for FRCs based on 1366 normal patient samples. The mean ± SD was 0.14 ± 0.35% and the median was 0% (95% confidence interval of the mean: 0.12-0.16%). We observed that the percentage of red blood cells with <17 pg of haemoglobin content (Hypo-He) was correlated to an FRC increase and that flagged results relating to red blood cells, reticulocytes or platelets might have presented with artefactually increased FRCs. The FRCs reference range (healthy subjects) should be useful for laboratory staff for selecting which blood smears to check optically. © 2015 John Wiley & Sons Ltd.
Lung volumes: measurement, clinical use, and coding.
Flesch, Judd D; Dine, C Jessica
2012-08-01
Measurement of lung volumes is an integral part of complete pulmonary function testing. Some lung volumes can be measured during spirometry; however, measurement of the residual volume (RV), functional residual capacity (FRC), and total lung capacity (TLC) requires special techniques. FRC is typically measured by one of three methods. Body plethysmography uses Boyle's Law to determine lung volumes, whereas inert gas dilution and nitrogen washout use dilution properties of gases. After determination of FRC, expiratory reserve volume and inspiratory vital capacity are measured, which allows the calculation of the RV and TLC. Lung volumes are commonly used for the diagnosis of restriction. In obstructive lung disease, they are used to assess for hyperinflation. Changes in lung volumes can also be seen in a number of other clinical conditions. Reimbursement for measurement of lung volumes requires knowledge of current procedural terminology (CPT) codes, relevant indications, and an appropriate level of physician supervision. Because of recent efforts to eliminate payment inefficiencies, the 10 previous CPT codes for lung volumes, airway resistance, and diffusing capacity have been bundled into four new CPT codes.
Damage Detection Response Characteristics of Open Circuit Resonant (SansEC) Sensors
NASA Technical Reports Server (NTRS)
Dudley, Kenneth L.; Szatkowski, George N.; Smith, Laura J.; Koppen, Sandra V.; Ely, Jay J.; Nguyen, Truong X.; Wang, Chuantong; Ticatch, Larry A.; Mielnik, John J.
2013-01-01
The capability to assess the current or future state of the health of an aircraft to improve safety, availability, and reliability while reducing maintenance costs has been a continuous goal for decades. Many companies, commercial entities, and academic institutions have become interested in Integrated Vehicle Health Management (IVHM) and a growing effort of research into "smart" vehicle sensing systems has emerged. Methods to detect damage to aircraft materials and structures have historically relied on visual inspection during pre-flight or post-flight operations by flight and ground crews. More quantitative non-destructive investigations with various instruments and sensors have traditionally been performed when the aircraft is out of operational service during major scheduled maintenance. Through the use of reliable sensors coupled with data monitoring, data mining, and data analysis techniques, the health state of a vehicle can be detected in-situ. NASA Langley Research Center (LaRC) is developing a composite aircraft skin damage detection method and system based on open circuit SansEC (Sans Electric Connection) sensor technology. Composite materials are increasingly used in modern aircraft for reducing weight, improving fuel efficiency, and enhancing the overall design, performance, and manufacturability of airborne vehicles. Materials such as fiberglass reinforced composites (FRC) and carbon-fiber-reinforced polymers (CFRP) are being used to great advantage in airframes, wings, engine nacelles, turbine blades, fairings, fuselage structures, empennage structures, control surfaces and aircraft skins. SansEC sensor technology is a new technical framework for designing, powering, and interrogating sensors to detect various types of damage in composite materials. The source cause of the in-service damage (lightning strike, impact damage, material fatigue, etc.) to the aircraft composite is not relevant. The sensor will detect damage independent of the cause. Damage in composite material is generally associated with a localized change in material permittivity and/or conductivity. These changes are sensed using SansEC. The unique electrical signatures (amplitude, frequency, bandwidth, and phase) are used for damage detection and diagnosis. An operational system and method would incorporate a SansEC sensor array on select areas of the aircraft exterior surfaces to form a "Smart skin" sensing surface. In this paper a new method and system for aircraft in-situ damage detection and diagnosis is presented. Experimental test results on seeded fault damage coupons and computational modeling simulation results are presented. NASA LaRC has demonstrated with individual sensors that SansEC sensors can be effectively used for in-situ composite damage detection of delamination, voids, fractures, and rips. Keywords: Damage Detection, Composites, Integrated Vehicle Health Monitoring (IVHM), Aviation Safety, SansEC Sensors
1970-06-20
The M2-F3 Lifting Body is seen here on the lakebed next to the NASA Flight Research Center (FRC--later Dryden Flight Research Center), Edwards, California. The May 1967 crash of the M2-F2 had torn off the left fin and landing gear. It had also damaged the external skin and internal structure. Flight Research Center engineers worked with Ames Research Center and the Air Force in redesigning the vehicle with a center fin to provide greater stability. Then Northrop Corporation cooperated with the FRC in rebuilding the vehicle. The entire process took three years.
Joosten, Simon A; Landry, Shane A; Sands, Scott A; Terrill, Philip I; Mann, Dwayne; Andara, Christopher; Skuza, Elizabeth; Turton, Anthony; Berger, Philip; Hamilton, Garun S; Edwards, Bradley A
2017-11-01
Obstructive sleep apnoea (OSA) is typically worse in the supine versus lateral sleeping position. One potential factor driving this observation is a decrease in lung volume in the supine position which is expected by theory to increase a key OSA pathogenic factor: dynamic ventilatory control instability (i.e. loop gain). We aimed to quantify dynamic loop gain in OSA patients in the lateral and supine positions, and to explore the relationship between change in dynamic loop gain and change in lung volume with position. Data from 20 patients enrolled in previous studies on the effect of body position on OSA pathogenesis were retrospectively analysed. Dynamic loop gain was calculated from routinely collected polysomnographic signals using a previously validated mathematical model. Lung volumes were measured in the awake state with a nitrogen washout technique. Dynamic loop gain was significantly higher in the supine than in the lateral position (0.77 ± 0.15 vs 0.68 ± 0.14, P = 0.012). Supine functional residual capacity (FRC) was significantly lower than lateral FRC (81.0 ± 15.4% vs 87.3 ± 18.4% of the seated FRC, P = 0.021). The reduced FRC we observed on moving to the supine position was predicted by theory to increase loop gain by 10.2 (0.6, 17.1)%, a value similar to the observed increase of 8.4 (-1.5, 31.0)%. Dynamic loop gain increased by a small but statistically significant amount when moving from the lateral to supine position and this may, in part, contribute to the worsening of OSA in the supine sleeping position. © 2017 Asian Pacific Society of Respirology.
Gustafsson, P M; Robinson, P D; Lindblad, A; Oberli, D
2016-11-01
Multiple-breath inert gas washout (MBW) is ideally suited for early detection and monitoring of serious lung disease, such as cystic fibrosis, in infants and young children. Validated commercial options for the MBW technique are limited, and suitability of nitrogen (N 2 )-based MBW is of concern given the detrimental effect of exposure to pure O 2 on infant breathing pattern. We propose novel methodology using commercially available N 2 MBW equipment to facilitate 4% sulfur hexafluoride (SF 6 ) multiple-breath inert gas wash-in and washout suitable for the infant age range. CO 2 , O 2 , and sidestream molar mass sensor signals were used to accurately calculate SF 6 concentrations. An improved dynamic method for synchronization of gas and respiratory flow was developed to take into account variations in sidestream sample flow during MBW measurement. In vitro validation of triplicate functional residual capacity (FRC) assessments was undertaken under dry ambient conditions using lung models ranging from 90 to 267 ml, with tidal volumes of 28-79 ml, and respiratory rates 20-60 per minute. The relative mean (SD, 95% confidence interval) error of triplicate FRC determinations by washout was -0.26 (1.84, -3.86 to +3.35)% and by wash-in was 0.57 (2.66, -4.66 to +5.79)%. The standard deviations [mean (SD)] of percentage error among FRC triplicates were 1.40 (1.14) and 1.38 (1.32) for washout and wash-in, respectively. The novel methodology presented achieved FRC accuracy as outlined by current MBW consensus recommendations (95% of measurements within 5% accuracy). Further clinical evaluation is required, but this new technique, using existing commercially available equipment, has exciting potential for research and clinical use. Copyright © 2016 the American Physiological Society.
Palmitate attenuates osteoblast differentiation of fetal rat calvarial cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeh, Lee-Chuan C.; Ford, Jeffery J.; Lee, John C.
Highlights: • Palmitate inhibits osteoblast differentiation. • Fatty acid synthase. • PPARγ. • Acetyl Co-A carboxylase inhibitor TOFA. • Fetal rat calvarial cell culture. - Abstract: Aging is associated with the accumulation of ectopic lipid resulting in the inhibition of normal organ function, a phenomenon known as lipotoxicity. Within the bone marrow microenvironment, elevation in fatty acid levels may produce an increase in osteoclast activity and a decrease in osteoblast number and function, thus contributing to age-related osteoporosis. However, little is known about lipotoxic mechanisms in intramembraneous bone. Previously we reported that the long chain saturated fatty acid palmitate inhibitedmore » the expression of the osteogenic markers RUNX2 and osteocalcin in fetal rat calvarial cell (FRC) cultures. Moreover, the acetyl CoA carboxylase inhibitor TOFA blocked the inhibitory effect of palmitate on expression of these two markers. In the current study we have extended these observations to show that palmitate inhibits spontaneous mineralized bone formation in FRC cultures in association with reduced mRNA expression of RUNX2, alkaline phosphatase, osteocalcin, and bone sialoprotein and reduced alkaline phosphatase activity. The effects of palmitate on osteogenic marker expression were inhibited by TOFA. Palmitate also inhibited the mRNA expression of fatty acid synthase and PPARγ in FRC cultures, and as with osteogenic markers, this effect was inhibited by TOFA. Palmitate had no effect on FRC cell proliferation or apoptosis, but inhibited BMP-7-induced alkaline phosphatase activity. We conclude that palmitate accumulation may lead to lipotoxic effects on osteoblast differentiation and mineralization and that increases in fatty acid oxidation may help to prevent these lipotoxic effects.« less
Johansen, B; Bjørtuft, O; Boe, J
1993-04-01
Single lung function is usually assessed by radioisotopes or, more rarely, by bronchospirometry in which a double lumen catheter is used to separate ventilation of the two lungs. The latter is more precise but less comfortable. An alternative bronchoscopic method is described for determining the volume of a single lung. One mainstem bronchus was temporarily occluded with an inflatable balloon during fibreoptic bronchoscopy in 12 healthy volunteers aged 18-29 years. The functional residual capacities (FRC) of the right, left, and both lungs were measured in duplicate by closed circuit helium dilution. Supplementary vital capacity (VC) manoeuvres permitted calculation of single lung capacities (TLC) and residual volumes (RV). The standard deviation of a single determination of capacities of the right, left, and both lungs were: TLC, 80, 96, and 308 ml; VC, 56, 139, 171 ml; FRC, 131, 74, and 287 ml; RV, 112, 185, and 303 ml, respectively. The sum of the right and left unilateral TLC was not different from bilateral TLC (6.12 v 5.95 l) and the sum of the unilateral FRC was not different from the bilateral FRC (2.60 v 2.78 l). The sum of the unilateral VC was lower than bilateral VC (4.52 v 4.80 l), that of the unilateral RV was higher than bilateral RV (1.60 v 1.16 l). For all subdivisions of lung volume, the right lung was larger than the left. The most common complaint was substernal discomfort during complete exhalation. Oxygen saturation rarely fell below 90%. Temporary occlusion of a mainstem bronchus in normal subjects is safe, relatively simple, and allows fairly precise and accurate measurements of unilateral static lung volumes. Occlusion at TLC, however, probably prevents proper emptying of the non-occluded lung.
Morales, Sinue I; Martínez, Ana M; Viñuela, Elisa; Chavarrieta, Juan M; Figueroa, José I; Schneider, Marcela I; Tamayo, Fernando; Pineda, Samuel
2018-05-28
Lethal and sublethal effects of refined soybean oil, imidacloprid, and abamectin on Tamarixia triozae (Burks; Hymenoptera: Eulophidae) were assessed after exposure of the eggs, larvae, and pupae of this parasitoid to three concentrations of these active substances: the LC50 for fourth-instar Bactericera cockerelli (Sulc.; Hemiptera: Triozidae) and 50% and 100% of the minimum field-registered concentration (MiFRC). Soybean oil caused 26-61% mortality in T. triozae eggs and 6-19% in larvae; mortality in both eggs and larvae was ≤19% for imidacloprid and 4-100% for abamectin. All three compounds caused <18% mortality of T. triozae pupae, with the exception of the abamectin 50% (47%) and 100% (72%) MiFRC. The mortality of larvae and pupae derived from treated eggs was ≤39% for all three insecticides, and that of pupae derived from treated larvae was ≤10%. In general, emergence of adults developed from treated eggs, larvae, and pupae was affected more by abamectin than by the other treatments. The proportion of females derived from all three development stages was not affected by treatment with the compounds, except when the parasitoid was treated as larvae with the soybean oil 100 and 50% MiFRC (66 and 68%, respectively) or when treated as pupae with the imidacloprid LC50 and 100% MiFRC (~60%). Female longevity was generally higher than that of males. The use of imidacloprid, soybean oil, and abamectin in combination with T. triozae for pest control may be effective when the parasitoid is in the pupal stage because this stage is less susceptible than other immature stages.
Commercial D-T FRC Power Plant Systems Analysis
NASA Astrophysics Data System (ADS)
Nguyen, Canh; Santarius, John; Emmert, Gilbert; Steinhauer, Loren; Stubna, Michael
1998-11-01
Results of an engineering issues scoping study of a Field-Reversed Configuration (FRC) burning D-T fuel will be presented. The study primarily focuses on engineering issues, such as tritium-breeding blanket design, radiation shielding, neutron damage, activation, safety, and environment. This presentation will concentrate on plasma physics, current drive, economics, and systems integration, which are important for the overall systems analysis. A systems code serves as the key tool in defining a reference point for detailed physics and engineering calculations plus parametric variations, and typical cases will be presented. Advantages of the cylindrical geometry and high beta (plasma pressure/magnetic-field pressure) are evident.
1970-06-19
The M2-F3 Lifting Body is seen here on the lakebed at the NASA Flight Research Center (FRC--later the Dryden Flight Research Center), Edwards, California. After a three-year-long redesign and rebuilding effort, the M2-F3 was ready to fly. The May 1967 crash of the M2-F2 had damaged both the external skin and the internal structure of the lifting body. At first, it seemed that the vehicle had been irreparably damaged, but the original manufacturer, Northrop, did the repair work and returned the redesigned M2-F3 with a center fin for stability to the FRC.
Overview of C-2W Field-Reversed Configuration Experimental Program
NASA Astrophysics Data System (ADS)
Gota, H.; Binderbauer, M. W.; Tajima, T.; Putvinski, S.; Tuszewski, M.; Dettrick, S.; Korepanov, S.; Romero, J.; Smirnov, A.; Song, Y.; Thompson, M. C.; van Drie, A.; Yang, X.; Ivanov, A. A.; TAE Team
2017-10-01
Tri Alpha Energy's research has been devoted to producing a high temperature, stable, long-lived field-reversed configuration (FRC) plasma state by neutral-beam injection (NBI) and edge biasing/control. C-2U experiments have demonstrated drastic improvements in particle and energy confinement properties of FRC's, and the plasma performance obtained via 10 MW NBI has achieved plasma sustainment of up to 5 ms and plasma (diamagnetism) lifetimes of 10 + ms. The emerging confinement scaling, whereby electron energy confinement time is proportional to a positive power of the electron temperature, is very attractive for higher energy plasma confinement; accordingly, verification of the observed Te scaling law will be a key future research objective. The new experimental device, C-2W (now also called ``Norman''), has the following key subsystem upgrades from C-2U: (i) higher injected power, optimum energies, and extended pulse duration of the NBI system; (ii) installation of inner divertors with upgraded edge-biasing systems; (iii) fast external equilibrium/mirror-coil current ramp-up capability; and (iv) installation of trim/saddle coils for active feedback control of the FRC plasma. This paper will review highlights of the C-2W program.
Two-dimensional interpreter for field-reversed configurations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinhauer, Loren, E-mail: lstein@uw.edu
2014-08-15
An interpretive method is developed for extracting details of the fully two-dimensional (2D) “internal” structure of field-reversed configurations (FRC) from common diagnostics. The challenge is that only external and “gross” diagnostics are routinely available in FRC experiments. Inferring such critical quantities as the poloidal flux and the particle inventory has commonly relied on a theoretical construct based on a quasi-one-dimensional approximation. Such inferences sometimes differ markedly from the more accurate, fully 2D reconstructions of equilibria. An interpreter based on a fully 2D reconstruction is needed to enable realistic within-the-shot tracking of evolving equilibrium properties. Presented here is a flexible equilibriummore » reconstruction with which an extensive data base of equilibria was constructed. An automated interpreter then uses this data base as a look-up table to extract evolving properties. This tool is applied to data from the FRC facility at Tri Alpha Energy. It yields surprising results at several points, such as the inferences that the local β (plasma pressure/external magnetic pressure) of the plasma climbs well above unity and the poloidal flux loss time is somewhat longer than previously thought, both of which arise from full two-dimensionality of FRCs.« less
NASA Astrophysics Data System (ADS)
Yang, Xiaokang; Petrov, Yuri; Ceccherini, Francesco; Koehn, Alf; Galeotti, Laura; Dettrick, Sean; Binderbauer, Michl
2017-10-01
Numerous efforts have been made at Tri-Alpha Energy (TAE) to theoretically explore the physics of microwave electron heating in field-reversed configuration (FRC) plasmas. For the fixed 2D profiles of plasma density and temperature for both electrons and thermal ions and equilibrium field of the C-2U machine, simulations with GENRAY-C ray-tracing code have been conducted for the ratios of ω/ωci[D] in the range of 6 - 20. Launch angles and antenna radial and axial positions have been optimized in order to simultaneously achieve good wave penetration into the core of FRC plasmas and efficient power damping on electrons. It is found that in an optimal regime, single pass absorption efficiency is 100% and most of the power is deposited inside the separatrix of FRC plasmas, with power damping efficiency of about 72% on electrons and less than 19% on ions. Calculations have clearly demonstrated that substantial power absorption on electrons is mainly attributed to high beta enhancement of magnetic pumping; complete power damping occurs before Landau damping has a significant effect on power absorption.
UEDGE Simulations for Power and Particle Flow Analysis of FRC Rocket
NASA Astrophysics Data System (ADS)
Zheng, Fred; Evans, Eugene S.; McGreivy, Nick; Kaptanoglu, Alan; Izacard, Olivier; Cohen, Samuel A.
2017-10-01
The field-reversed configuration (FRC) is under consideration for use in a direct fusion drive (DFD) rocket propulsion system for future space missions. To achieve a rocket configuration, the FRC is embedded within an asymmetric magnetic mirror, in which one end is closed and contains a gas box, and the other end is open and incorporates a magnetic nozzle. Neutral deuterium is injected into the gas box, and flows through the scrape-off layer (SOL) around the core plasma and out the magnetic nozzle, both cooling the core and serving as propellant. Previous studies have examined a range of operating conditions for the SOL of a DFD using UEDGE, a 2D fluid code; discrepancies on the order of 5% were found during the analysis of overall power balance. This work extends the analysis of the previously-studied SOL geometry by updating boundary conditions and conducting a detailed study of power and particle flows within the simulation with the goals of modeling electrical power generation instead of thrust and achieving higher specific impulse. This work was supported, in part, by DOE Contract Number DE-AC02-09CH11466 and Princeton Environmental Institute.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Velas, K. M.; Milroy, R. D.
A translatable three-axis probe was constructed and installed on the translation, confinement, and sustainment upgrade (TCSU) experiment. With ninety windings, the probe can simultaneously measure B{sub r}, B{sub θ}, and B{sub z} at 30 radial positions, and can be placed at any desired axial position within the field reversed configuration (FRC) confinement chamber. Positioning the probe at multiple axial positions and taking multiple repeatable shots allows for a full r-z map of the magnetic field. Measurements were made for odd-parity rotating magnetic field (RMF) antennas and even-parity RMF. The steady state data from applying a 10 kHz low pass filter usedmore » in conjunction with data at the RMF frequency yields a map of the full 3D rotating field structure. Comparisons will be made to the 3D magnetic structure predicted by NIMROD simulations, with parameters adjusted to match that of the TCSU experiments. The probe provides sufficient data to utilize a Maxwell stress tensor approach to directly measure the torque applied to the FRC's electrons, which combined with a resistive torque model, yields an estimate of the average FRC resistivity.« less
Anaerobic U(IV) Bio-oxidation and the Resultant Remobilization of Uranium in Contaminated Sediments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coates, John D.
2005-06-01
A proposed strategy for the remediation of uranium (U) contaminated sites is based on immobilizing U by reducing the oxidized soluble U, U(VI), to form a reduced insoluble end product, U(IV). Due to the use of nitric acid in the processing of nuclear fuels, nitrate is often a co-contaminant found in many of the environments contaminated with uranium. Recent studies indicate that nitrate inhibits U(VI) reduction in sediment slurries. However, the mechanism responsible for the apparent inhibition of U(VI) reduction is unknown, i.e. preferential utilization of nitrate as an electron acceptor, direct biological oxidation of U(IV) coupled to nitrate reduction,more » and/or abiotic oxidation by intermediates of nitrate reduction. Recent studies indicates that direct biological oxidation of U(IV) coupled to nitrate reduction may exist in situ, however, to date no organisms have been identified that can grow by this metabolism. In an effort to evaluate the potential for nitrate-dependent bio-oxidation of U(IV) in anaerobic sedimentary environments, we have initiated the enumeration of nitrate-dependent U(IV) oxidizing bacteria. Sediments, soils, and groundwater from uranium (U) contaminated sites, including subsurface sediments from the NABIR Field Research Center (FRC), as well as uncontaminated sites, including subsurface sediments from the NABIR FRC and Longhorn Army Ammunition Plant, Texas, lake sediments, and agricultural field soil, sites served as the inoculum source. Enumeration of the nitrate-dependent U(IV) oxidizing microbial population in sedimentary environments by most probable number technique have revealed sedimentary microbial populations ranging from 9.3 x 101 - 2.4 x 103 cells (g sediment)-1 in both contaminated and uncontaminated sites. Interestingly uncontaminated subsurface sediments (NABIR FRC Background core FB618 and Longhorn Texas Core BH2-18) both harbored the most numerous nitrate-dependent U(IV) oxidizing population 2.4 x 103 cells (g sediment)-1. The nitrate-dependent U(IV) oxidizing microbial population in groundwaters is less numerous ranging from 0 cells mL-1 (Well FW300, Uncontaminated Background NABIR FRC) to 4.3 x 102 cells mL-1 (Well TPB16, Contaminated Area 2 NABIR FRC). The presence of nitrate-dependent U(IV) oxidizing bacteria supports our hypothesis that bacteria capable of anaerobic U(IV) oxidation are ubiquitous and indigenous to sedimentary and groundwater environments.« less
Denehy, L; Carroll, S; Ntoumenopoulos, G; Jenkins, S
2001-01-01
Physiotherapists use a variety of techniques aimed at improving lung volumes and secretion clearance in patients after surgery. Periodic continuous positive airway pressure (PCPAP) is used to treat patients following elective upper abdominal surgery. However, the optimal method of application has not been identified, more specifically, the dosage of application of PCPAP. The present randomized controlled trial compared the effects of two dosages of PCPAP application and 'traditional' physiotherapy upon functional residual capacity (FRC), vital capacity (VC), oxyhaemoglobin saturation (SpO2), incidence of post-operative pulmonary complications and length of stay with a control group receiving 'traditional' physiotherapy only. Fifty-seven subjects were randomly allocated to one of three groups. All groups received 'traditional' physiotherapy twice daily for a minimum of three post-operative days. In addition, two groups received PCPAP for 15 or 30 minutes, four times per day, for three days. Fifty subjects (39 male; 11 female) completed the study. There were no significant differences in any variables between the three groups. The overall incidence of post-operative pulmonary complications was 22% in the control group, 11% and 6% in the PCPAP 15-minute and PCPAP 30-minute groups, respectively. Length of hospital stay was not significantly different between the groups but for subjects who developed post-operative pulmonary complications, the length of stay was significantly greater (Z = -2.32; p = 0.021). The addition of PCPAP to a traditional physiotherapy post-operative treatment regimen after upper abdominal surgery did not significantly affect physiological or clinical outcomes.
Generation of Spatially Aligned Collagen Fiber Networks through Microtransfer Molding
Naik, Nisarga; Caves, Jeffrey
2013-01-01
The unique biomechanical properties of native tissue are governed by the organization and composition of integrated collagen and elastin networks. We report an approach for fabricating spatially aligned, fiber-reinforced composites (FRC) with adjustable collagen fiber dimensions, layouts, and distribution within an elastin-like protein matrix yielding a biocomposite with controllable mechanical responses. Microtransfer molding is employed for the fabrication of hollow and solid collagen fibers with straight or crimped fiber geometries. Collagen fibers (width: 2 – 50 μm, thickness: 300 nm – 3 μm) exhibit a Young’s modulus of 126 ± 61 MPa and an ultimate tensile strength (UTS) of 7 ± 3.2 MPa. As fiber networks within composite structures, straight fiber layouts display orthotropic responses with Young’s modulus ranging from 0.95 ± 0.35 to 10.4 ± 0.5 MPa and tensile strength from 0.22 ± 0.08 to 0.87 ± 0.5 MPa with increasing fraction of collagen fibers (1–10% v/v). In contrast, composites based on crimped fiber layouts exhibit strain-dependent stiffness with an increase in Young’s modulus from 0.7 ± 0.14 MPa to 3.15 ± 0.49 MPa, at a specific transition strain. Through controlling the microstructure of engineered collagen fiber networks, a facile means has been established to control macroscale mechanical responses of composite protein-based materials. PMID:24039146
NASA Technical Reports Server (NTRS)
Wang, Chuantong; Dudley, Kenneth L.; Szatkowski, George N.
2012-01-01
Composite materials are increasingly used in modern aircraft for reducing weight, improving fuel efficiency, and enhancing the overall design, performance, and manufacturability of airborne vehicles. Materials such as fiberglass reinforced composites (FRC) and carbon-fiber-reinforced polymers (CFRP) are being used to great advantage in airframes, wings, engine nacelles, turbine blades, fairings, fuselage and empennage structures, control surfaces and coverings. However, the potential damage from the direct and indirect effects of lightning strikes is of increased concern to aircraft designers and operators. When a lightning strike occurs, the points of attachment and detachment on the aircraft surface must be found by visual inspection, and then assessed for damage by maintenance personnel to ensure continued safe flight operations. In this paper, a new method and system for aircraft in-situ damage detection and diagnosis are presented. The method and system are based on open circuit (SansEC) sensor technology developed at NASA Langley Research Center. SansEC (Sans Electric Connection) sensor technology is a new technical framework for designing, powering, and interrogating sensors to detect damage in composite materials. Damage in composite material is generally associated with a localized change in material permittivity and/or conductivity. These changes are sensed using SansEC. Unique electrical signatures are used for damage detection and diagnosis. NASA LaRC has both experimentally and theoretically demonstrated that SansEC sensors can be effectively used for in-situ composite damage detection.
Time dependent changes of material properties of FRC due to intensive heating
NASA Astrophysics Data System (ADS)
Prochazka, Petr P.
2014-02-01
Studies on porous media, particularly on fiber-reinforced concrete (FRC), which is exposed to various temperature conditions, are of great concern for engineers and researchers in wide scale of civil and underground construction. The problem consists in a relatively very complicated description of processes which the concrete undergoes during the change of loading conditions, such as change of temperature (fire), wetting, moistening, attack by chemical substances, etc. There are too many variables which should be observed and their mutual effect should be taken into consideration. If a structure is loaded by a change of temperature on one boundary surface, a texture of the concrete varies and the phases inside the concrete adopt the temperature conditions. In this paper, a numerical study based on 3D finite elements, and an experimental one based on the effect of various conditions of temperature, degree of saturation of gaseous and water parts in pores and vapor are carried out. The parameters in the numerical study are tuned according to the results from the experiments. The theory is established based on thermodynamic laws, Fourier's law, Fick's law, balance conditions, etc. An immediate application of the results from this paper is in underground structures, mainly in concrete (FRC) linings of tunnels. More general applications are much wider.
LSP simulations of fast ions slowing down in cool magnetized plasma
NASA Astrophysics Data System (ADS)
Evans, Eugene S.; Cohen, Samuel A.
2015-11-01
In MFE devices, rapid transport of fusion products, e.g., tritons and alpha particles, from the plasma core into the scrape-off layer (SOL) could perform the dual roles of energy and ash removal. Through these two processes in the SOL, the fast particle slowing-down time will have a major effect on the energy balance of a fusion reactor and its neutron emissions, topics of great importance. In small field-reversed configuration (FRC) devices, the first-orbit trajectories of most fusion products will traverse the SOL, potentially allowing those particles to deposit their energy in the SOL and eventually be exhausted along the open field lines. However, the dynamics of the fast-ion energy loss processes under conditions expected in the FRC SOL, where the Debye length is greater than the electron gyroradius, are not fully understood. What modifications to the classical slowing down rate are necessary? Will instabilities accelerate the energy loss? We use LSP, a 3D PIC code, to examine the effects of SOL plasma parameters (density, temperature and background magnetic field strength) on the slowing down time of fast ions in a cool plasma with parameters similar to those expected in the SOL of small FRC reactors. This work supported by DOE contract DE-AC02-09CH11466.
The Effect of Compartmental Asymmetry on the Monitoring of Pulmonary Mechanics and Lung Volumes.
Keenan, Joseph C; Cortes-Puentes, Gustavo A; Adams, Alexander B; Dries, David J; Marini, John J
2016-11-01
Esophageal pressure measurement for computation of transpulmonary pressure (P tp ) has begun to be incorporated into clinical use for evaluating forces across the lungs. Gaps exist in our understanding of how esophageal pressure (and therefore P tp ), a value measured at a single site, responds when respiratory system compartments are asymmetrically affected by whole-lung atelectasis or unilateral injury as well as changes in chest wall compliance. We reasoned that P tp would track with aerated volume changes as estimated by functional residual capacity (FRC) and tidal volume. We examined this hypothesis in the setting of asymmetric lungs and changes in intra-abdominal pressure. This study was conducted in the animal laboratory of a university-affiliated hospital. Models of unilateral atelectasis and unilateral and bilateral lung injury exposed to intra-abdominal hypertension (IAH) in 10 deeply sedated mechanically ventilated swine. Atelectasis was created by balloon occlusion of the left main bronchus. Unilateral lung injury was induced by saline lavage of isolated right lung. Diffuse lung injury was induced by saline lavage of both lungs. The peritoneum was insufflated with air to create a model of pressure-regulated IAH. We measured esophageal pressures, airway pressures, FRC by gas dilution, and oxygenation. FRC was reduced by IAH in normal lungs (P < .001) and both asymmetric lung pathologies (P < .001). P tp at end-expiration was decreased by IAH in bilateral (P = .001) and unilateral lung injury (P = .003) as well as unilateral atelectasis (P = .019). In the setting of both lung injury models, end-expiratory P tp showed a moderate correlation in tracking with FRC. P tp tracks with aerated lung volume in the setting of thoracic asymmetry and changes in intra-abdominal pressure. However, used alone, it cannot distinguish the relative contributions of air-space distention and recruitment of lung units. Copyright © 2016 by Daedalus Enterprises.
THE PHYSICS OF THE FAR-INFRARED-RADIO CORRELATION. I. CALORIMETRY, CONSPIRACY, AND IMPLICATIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lacki, Brian C.; Thompson, Todd A.; Quataert, Eliot, E-mail: lacki@astronomy.ohio-state.ed
2010-07-01
The far-infrared (FIR) and radio luminosities of star-forming galaxies are linearly correlated over a very wide range in star formation rate, from normal spirals like the Milky Way to the most intense starbursts. Using one-zone models of cosmic ray (CR) injection, cooling, and escape in star-forming galaxies, we attempt to reproduce the observed FIR-radio correlation (FRC) over its entire span. The normalization and linearity of the FRC, together with constraints on the CR population in the Milky Way, have strong implications for the CR and magnetic energy densities in star-forming galaxies. We show that for consistency with the FRC, {approx}2%more » of the kinetic energy from supernova explosions must go into high-energy primary CR electrons and that {approx}10%-20% must go into high-energy primary CR protons. Secondary electrons and positrons are likely comparable to or dominate primary electrons in dense starburst galaxies. We discuss the implications of our models for the magnetic field strengths of starbursts, the detectability of starbursts by Fermi, and CR feedback. Overall, our models indicate that both CR protons and electrons escape from low surface density galaxies, but lose most of their energy before escaping dense starbursts. The FRC is caused by a combination of the efficient cooling of CR electrons (calorimetry) in starbursts and a conspiracy of several factors. For lower surface density galaxies, the decreasing radio emission caused by CR escape is balanced by the decreasing FIR emission caused by the low effective UV dust opacity. In starbursts, bremsstrahlung, ionization, and inverse Compton cooling decrease the radio emission, but they are countered by secondary electrons/positrons and the dependence of synchrotron frequency on energy, both of which increase the radio emission. Our conclusions hold for a broad range of variations in our fiducial model, such as those including winds, different magnetic field strengths, and different diffusive escape times.« less
NASA Astrophysics Data System (ADS)
Yang, Zhong; Zhang, BoMing; Zhao, Lin; Sun, XinYang
2011-02-01
A shear-lag model is applied to study the stress transfer around a broken fiber within unidirectional fiber-reinforced composites (FRC) subjected to uniaxial tensile loading along the fiber direction. The matrix damage and interfacial debonding, which are the main failure modes, are considered in the model. The maximum stress criterion with the linear damage evolution theory is used for the matrix. The slipping friction stress is considered in the interfacial debonding region using Coulomb friction theory, in which interfacial clamping stress comes from radial residual stress and mismatch of Poisson's ratios of constituents (fiber and matrix). The stress distributions in the fiber and matrix are obtained by the shear-lag theory added with boundary conditions, which includes force continuity and displacement compatibility constraints in the broken and neighboring intact fibers. The result gives axial stress distribution in fibers and shear stress in the interface and compares the theory reasonably well with the measurement by a polarized light microscope. The relation curves between damage, debonding and ineffective region lengths with external strain loading are obtained.
Characterization of compact-toroid injection during formation, translation, and field penetration
NASA Astrophysics Data System (ADS)
Matsumoto, T.; Roche, T.; Allfrey, I.; Sekiguchi, J.; Asai, T.; Gota, H.; Cordero, M.; Garate, E.; Kinley, J.; Valentine, T.; Waggoner, W.; Binderbauer, M.; Tajima, T.
2016-11-01
We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ˜1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation, ejection/translation from the MCPG, and penetration into transverse magnetic fields.
Plasma-gun-assisted field-reversed configuration formation in a conical θ-pinch
NASA Astrophysics Data System (ADS)
Weber, T. E.; Intrator, T. P.; Smith, R. J.
2015-04-01
Injection of plasma via an annular array of coaxial plasma guns during the pre-ionization phase of field-reversed configuration (FRC) formation is shown to catalyze the bulk ionization of a neutral gas prefill in the presence of a strong axial magnetic field and change the character of outward flux flow during field-reversal from a convective process to a much slower resistive diffusion process. This approach has been found to significantly improve FRC formation in a conical θ-pinch, resulting in a ˜350% increase in trapped flux at typical operating conditions, an expansion of accessible formation parameter space to lower densities and higher temperatures, and a reduction or elimination of several deleterious effects associated with the pre-ionization phase.
Characterization of compact-toroid injection during formation, translation, and field penetration.
Matsumoto, T; Roche, T; Allfrey, I; Sekiguchi, J; Asai, T; Gota, H; Cordero, M; Garate, E; Kinley, J; Valentine, T; Waggoner, W; Binderbauer, M; Tajima, T
2016-11-01
We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ∼1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation, ejection/translation from the MCPG, and penetration into transverse magnetic fields.
Ideal-Magnetohydrodynamic-Stable Tilting in Field-Reversed Configurations
NASA Astrophysics Data System (ADS)
Kanno, Ryutaro; Ishida, Akio; Steinhauer, Loren
1995-02-01
The tilting mode in field-reversed configurations (FRC) is examined using ideal-magnetohydrodynamic stability theory. Tilting, a global mode, is the greatest threat for disruption of FRC confinement. Previous studies uniformly found tilting to be unstable in ideal theory: the objective here is to ascertain if stable equilibria were overlooked in past work. Solving the variational problem with the Rayleigh-Ritz technique, tilting-stable equilibria are found for sufficiently hollow current profile and sufficient racetrackness of the separatrix shape. Although these equilibria were not examined previously, the present conclusion is quite surprising. Consequently checks of the method are offered. Even so it cannot yet be claimed with complete certainty that stability has been proved: absolute confirmation of ideal-stable tilting awaits the application of more complete methods.
Multi-Fluid Simulations of Field Reversed Configuration Formation
NASA Astrophysics Data System (ADS)
Sousa, Eder; Martin, Robert
2017-10-01
The use of field reversed configuration (FRC) have been studied extensively for fusion application but here we investigate them for propulsion purposes. FRCs have the potential to produce highly variable thrust and specific impulse using different gases as propellant. Aspects of the FRC formation physics, using a rotating magnetic field (RMF) at low power, are simulated using a multi-fluid plasma model. Results are compared with experimental observations with emphasis in the development of instabilities and robustness of the field reversal. The use of collisional radiative models are used to help compare experiment versus simulation results. Distribution A: Approved for public release; distribution unlimited; Clearance No. 17445. This work is supported by the Air Force Office of Scientific Research Grant Number 17RQCOR465.
Numerical studies of fast ion slowing down rates in cool magnetized plasma using LSP
NASA Astrophysics Data System (ADS)
Evans, Eugene S.; Kolmes, Elijah; Cohen, Samuel A.; Rognlien, Tom; Cohen, Bruce; Meier, Eric; Welch, Dale R.
2016-10-01
In MFE devices, rapid transport of fusion products from the core into the scrape-off layer (SOL) could perform the dual roles of energy and ash removal. The first-orbit trajectories of most fusion products from small field-reversed configuration (FRC) devices will traverse the SOL, allowing those particles to deposit their energy in the SOL and be exhausted along the open field lines. Thus, the fast ion slowing-down time should affect the energy balance of an FRC reactor and its neutron emissions. However, the dynamics of fast ion energy loss processes under the conditions expected in the FRC SOL (with ρe <λDe) are analytically complex, and not yet fully understood. We use LSP, a 3D electromagnetic PIC code, to examine the effects of SOL density and background B-field on the slowing-down time of fast ions in a cool plasma. As we use explicit algorithms, these simulations must spatially resolve both ρe and λDe, as well as temporally resolve both Ωe and ωpe, increasing computation time. Scaling studies of the fast ion charge (Z) and background plasma density are in good agreement with unmagnetized slowing down theory. Notably, Z-scaling represents a viable way to dramatically reduce the required CPU time for each simulation. This work was supported, in part, by DOE Contract Number DE-AC02-09CH11466.
Long, David E; Tann, Mark; Huang, Ke Colin; Bartlett, Gregory; Galle, James O; Furukawa, Yukie; Maluccio, Mary; Cox, John A; Kong, Feng-Ming Spring; Ellsworth, Susannah G
2018-05-01
Hepatobiliary iminodiacetic acid (HIDA) scans provide global and regional assessments of liver function that can serve as a road map for functional avoidance in stereotactic body radiation therapy (SBRT) planning. Functional liver image guided hepatic therapy (FLIGHT), an innovative planning technique, is described and compared with standard planning using functional dose-volume histograms. Thresholds predicting for decompensation during follow up are evaluated. We studied 17 patients who underwent HIDA scans before SBRT. All SBRT cases were replanned using FLIGHT. The following dosimetric endpoints were compared for FLIGHT versus standard SBRT planning: functional residual capacity <15 Gy (FRC 15 HIDA), mean liver dose (MLD), equivalent uniform dose (EUD), and functional EUD (FEUD). Receiver operating characteristics curves were used to evaluate whether baseline HIDA values, standard cirrhosis scoring, and/or dosimetric data predicted clinical decompensation. Compared with standard planning, FLIGHT significantly improved FRC 15 HIDA (mean improvement: 5.3%) as well as MLD, EUD, and FEUD (P < .05). Considerable interindividual variations in the extent of benefit were noted. Decompensation during follow-up was associated with baseline global HIDA <2.915%/min/m 2 , FRC 15 HIDA <2.11%/min/m 2 , and MELD ≥11 (P < .05). FLIGHT with HIDA-based parameters may complement blood chemistry-based assessments of liver function and facilitate individualized, adaptive liver SBRT planning. Copyright © 2018. Published by Elsevier Inc.
Simulating free-roaming cat population management options in open demographic environments.
Miller, Philip S; Boone, John D; Briggs, Joyce R; Lawler, Dennis F; Levy, Julie K; Nutter, Felicia B; Slater, Margaret; Zawistowski, Stephen
2014-01-01
Large populations of free-roaming cats (FRCs) generate ongoing concerns for welfare of both individual animals and populations, for human public health, for viability of native wildlife populations, and for local ecological damage. Managing FRC populations is a complex task, without universal agreement on best practices. Previous analyses that use simulation modeling tools to evaluate alternative management methods have focused on relative efficacy of removal (or trap-return, TR), typically involving euthanasia, and sterilization (or trap-neuter-return, TNR) in demographically isolated populations. We used a stochastic demographic simulation approach to evaluate removal, permanent sterilization, and two postulated methods of temporary contraception for FRC population management. Our models include demographic connectivity to neighboring untreated cat populations through natural dispersal in a metapopulation context across urban and rural landscapes, and also feature abandonment of owned animals. Within population type, a given implementation rate of the TR strategy results in the most rapid rate of population decline and (when populations are isolated) the highest probability of population elimination, followed in order of decreasing efficacy by equivalent rates of implementation of TNR and temporary contraception. Even low levels of demographic connectivity significantly reduce the effectiveness of any management intervention, and continued abandonment is similarly problematic. This is the first demographic simulation analysis to consider the use of temporary contraception and account for the realities of FRC dispersal and owned cat abandonment.
From the Journal archives: Airway closure and lung volumes in surgical positions.
Grocott, Hilary P
2014-04-01
Douglas B. Craig, W.M. Wahba, Hillary Don Can Anaesth Soc J 1971; 18: 92-9. Surgery and anesthesia expose patients to moderate and sometimes extreme positioning changes that are often unphysiological. The purpose of this article is to highlight and contextualize a seminal study from the Journal archives that explores the effect of several commonly utilized surgical positions (supine, Trendelenburg and lithotomy) and age on basic lung volumes as well as the volume at which small airway closure (AC) (also known as closing volume [CV]) occurs. These factors were examined with the aim of determining which patient position variables could be of clinical significance to gas exchange in the perioperative period. This work showed that supine positioning, when compared with the seated position, results in a decrease of all lung volumes and capacities, including functional residual capacity (FRC) and CV. Trendelenburg positioning further decreases FRC, with no further changes induced by lithotomy positioning. Age is a clinically important factor in AC, occurring within the tidal volume range at a lower age when supine as compared with the seated position. The work of Drs. D. Craig et al. published in the Journal more than 40 years ago was seminal to our understanding of how patient positioning has an important influence on lung volumes and on the age-related relationship between FRC and CV.
North American Society for Pediatric and Adolescent Gynecology
... and Long Curriculum U.S. Medical Eligibility Criteria for Contraceptive Use, 2016 U.S. Selected Practice Recommendations for Contraceptive Use, 2016 NASPAG Fellows Research Consortium (FRC) RENEW ...
Plasma-gun-assisted field-reversed configuration formation in a conical θ-pinch
Weber, T. E.; Intrator, T. P.; Smith, R. J.
2015-04-29
We show through injection of plasma via an annular array of coaxial plasma guns, during the pre-ionization phase of field-reversed configuration (FRC) formation how to catalyze the bulk ionization of a neutral gas prefill in the presence of a strong axial magnetic field and change the character of outward flux flow during field-reversal from a convective process to a much slower resistive diffusion process. Our approach has been found to significantly improve FRC formation in a conical θ-pinch, resulting in a ~350% increase in trapped flux at typical operating conditions, an expansion of accessible formation parameter space to lower densitiesmore » and higher temperatures, and a reduction or elimination of several deleterious effects associated with the pre-ionization phase.« less
Plasma-gun-assisted field-reversed configuration formation in a conical θ-pinch
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weber, T. E., E-mail: tweber@lanl.gov; Intrator, T. P.; Smith, R. J.
2015-04-15
Injection of plasma via an annular array of coaxial plasma guns during the pre-ionization phase of field-reversed configuration (FRC) formation is shown to catalyze the bulk ionization of a neutral gas prefill in the presence of a strong axial magnetic field and change the character of outward flux flow during field-reversal from a convective process to a much slower resistive diffusion process. This approach has been found to significantly improve FRC formation in a conical θ-pinch, resulting in a ∼350% increase in trapped flux at typical operating conditions, an expansion of accessible formation parameter space to lower densities and highermore » temperatures, and a reduction or elimination of several deleterious effects associated with the pre-ionization phase.« less
Characterization of compact-toroid injection during formation, translation, and field penetration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matsumoto, T., E-mail: cstd14003@g.nihon-u.ac.jp; Sekiguchi, J.; Asai, T.
2016-11-15
We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ∼1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation,more » ejection/translation from the MCPG, and penetration into transverse magnetic fields.« less
Magnetic and electrostatic confinement of plasma with tuning of electrostatic field
Rostoker, Norman [Irvine, CA; Binderbauer, Michl [Irvine, CA; Qerushi, Artan [Irvine, CA; Tahsiri, Hooshang [Irvine, CA
2008-10-21
A system and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions they are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.
Magnetic and electrostatic confinement of plasma with tuning of electrostatic field
Rostoker, Norman; Binderbauer, Michl; Qerushi, Artan; Tahsiri, Hooshang
2006-10-10
A system and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions they are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.
Apparatus for magnetic and electrostatic confinement of plasma
Rostoker, Norman; Binderbauer, Michl
2013-06-11
An apparatus and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions ions are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.
Apparatus for magnetic and electrostatic confinement of plasma
Rostoker, Norman; Binderbauer, Michl
2016-07-05
An apparatus and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions ions are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.
Apparatus for magnetic and electrostatic confinement of plasma
Rostoker, Norman; Binderbauer, Michl
2006-10-31
An apparatus and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions they are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.
Apparatus for magnetic and electrostatic confinement of plasma
Rostoker, Norman; Binderbauer, Michl
2006-04-11
An apparatus and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions they are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.
Apparatus for magnetic and electrostatic confinement of plasma
Rostoker, Norman [Irvine, CA; Binderbauer, Michl [Irvine, CA
2009-08-04
An apparatus and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions ions are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.
Magnetic and electrostatic confinement of plasma with tuning of electrostatic field
Rostoker, Norman; Binderbauer, Michl; Qerushi, Artan; Tahsiri, Hooshang
2006-03-21
A system and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions they are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.
Dikbas, Idil; Tanalp, Jale; Koksal, Temel; Yalnız, Ayşe; Güngör, Tufan
2014-02-01
The aim of this study was to assess fracture resistances of simulated immature single-rooted teeth whose roots have been backfilled using 3 different post systems after a 4 mm apical mineral trioxide aggregate (MTA) placement. Forty-eight maxillary anterior teeth were assigned into four groups. The lengths of each root were standardized by cutting off the coronal and apical portions to obtain 13 ± 1 mm samples and root canals were enlarged. The #6 Peeso reamers were allowed to protrude 1 mm beyond apex to simulate immature teeth. Apical 4 mm of each tooth was filled using MTA. The remaining portions were treated as follows: Group 1 (Control): AH Plus + Gutta-percha cold lateral compaction. Group 2: Glass fiber posts (FRC Postec Plus post) cemented using self-adhesive resin cement. Group 3: Quartz fiber posts (D.T. Light post) cemented using self-adhesive resin cement. Group 4: Zirconia posts (Cosmopost) were placed using self-adhesive resin cement. Specimens were embedded in self-curing acrylic. A compressive load was applied lingually at a crosshead speed of 1 mm/min at an angle of 45º until fracture in a universal testing machine. The mean fracture resistances were 823.17 ± 188.80, 1155.50 ± 190.37, 1208.00 ± 254.32, and 1153.25 ± 195.71 Newtons for Groups 1, 2, 3, and 4, respectively. All experimental groups had significantly higher fracture resistance compared with the control group (P < 0.01). No statistically significant difference was noted between the experimental groups (P > 0.05). All post systems exerted a similar reinforcing effect to a simulated immature tooth and may be preferred specifically in situations which require additional reinforcement. © 2013 John Wiley & Sons A/S.
Effect of thermal cycling on composites reinforced with two differently sized silica-glass fibers.
Meriç, Gökçe; Ruyter, I Eystein
2007-09-01
To evaluate the effects of thermal cycling on the flexural properties of composites reinforced with two differently sized fibers. Acid-washed, woven, fused silica-glass fibers, were heat-treated at 500 degrees C, silanized and sized with one of two sizing resins (linear poly(butyl methacrylate)) (PBMA), cross-linked poly(methyl methacrylate) (PMMA). Subsequently the fibers were incorporated into a polymer matrix. Two test groups with fibers and one control group without fibers were prepared. The flexural properties of the composite reinforced with linear PBMA-sized fibers were evaluated by 3-point bend testing before thermal cycling. The specimens from all three groups were thermally cycled in water (12,000 cycles, 5/55 degrees C, dwell time 30 s), and afterwards tested by 3-point bending. SEM micrographs were taken of the fibers and of the fractured fiber reinforced composites (FRC). The reduction of ultimate flexural strength after thermal cycling was less than 20% of that prior to thermal cycling for composites reinforced with linear PBMA-sized silica-glass fibers. The flexural strength of the composite reinforced with cross-linked PMMA-sized fibers was reduced to less than half of the initial value. This study demonstrated that thermal cycling differently influences the flexural properties of composites reinforced with different sized silica-glass fibers. The interfacial linear PBMA-sizing polymer acts as a stress-bearing component for the high interfacial stresses during thermal cycling due to the flexible structure of the linear PBMA above Tg. The cross-linked PMMA-sizing, however, acts as a rigid component and therefore causes adhesive fracture between the fibers and matrix after the fatigue process of thermal cycling and flexural fracture.
Graphite coated PVA fibers as the reinforcement for cementitious composites
NASA Astrophysics Data System (ADS)
Zhang, Yunhua; Zhang, Zhipeng; Liu, Zhichao
2018-02-01
A new preconditioning method was developed to PVA fibers as the reinforcement in cement-based materials. Virgin PVA fibers exhibits limited adhesion to graphite powders due to the presence of oil spots on the surface. Mixing PVA fibers with a moderately concentrated KMnO4-H2SO4 solution can efficiently remove the oil spots by oxidation without creating extra precipitate (MnO2) associated with the reduction reaction. This enhances the coating of graphite powders onto fiber surface and improves the mechanical properties of PVA fiber reinforced concrete (PVA-FRC). Graphite powders yields better fiber distribution in the matrix and reduces the fiber-matrix bonding, which is beneficial in uniformly distributing the stress among embedded fibers and creating steady generation and propagation of tight microcracks. This is evidenced by the significantly enhanced strain hardening behavior and improved flexural strength and toughness.
NASA Astrophysics Data System (ADS)
Webb, Horace P.
Doing and learning science are social activities that require certain language, activities, and values. Both constitute what Gee (2005) calls Discourses. The language of learning science varies with the learning context (Lemke, 2001,1990). Science for All Americans (AAAS, 1990) and Inquiry and the National Science Education Standards (NRC, 2000) endorse inquiry science learning. In the United States, most science learning is teacher-centered; inquiry science learning is rare (NRC, 2000). This study focused on 12 high school students from two suburban high schools, their three faculty mentors, and two engineering mentors during an extracurricular robotics activity with FIRST Robotics Competition (FRC). FRC employed student-centered inquiry focus to teach science principles integrating technology. Research questions were (a) How do science teachers and their students enact Discourses as they teach and learn science? and (b) How does the pedagogical approach of a learning activity facilitate the Discourses that are enacted by students and teachers as they learn and teach science? Using Critical Discourse Analysis (CDA), the study examined participants' language during robotic activities to determine how language used in learning science shaped the learning and vice versa. Data sources included videorecordings of participant language and semi-structured interviews with study participants. Transcribed recordings were coded initially using Gee's (2005) linguistic Building Tasks as a priori codes. CDA was applied to code transcripts, to construct Discourses enacted by the participants, and to determine how context facilitated their enactment. Findings indicated that, for the students, FRC facilitated elements of Science Discourse. Wild About Robotics (W.A.R.) team became, through FRC, part of a community similar to scientists' community that promoted knowledge and sound practices, disseminated information, supported research and development and encouraged interaction of its members. The public school science classroom in the U.S. is inimical to inquiry learning because of practices and policies associated with the epistemological stance that spawned the standards and/or testing movement and No Child Left Behind (Baez & Boyles, 2009). The findings of this study provided concrete ideas to accommodate the recommendations by NRC (1996) and NSES (2000) for creating contexts that might lead to inquiry science learning for meaningful student engagement.
Bitter, Kerstin; Gläser, Christin; Neumann, Konrad; Blunck, Uwe; Frankenberger, Roland
2014-01-01
Purpose Restoration of endodontically treated teeth using fiber posts in a one-stage procedure gains more popularity and aims to create a secondary monoblock. Data of detailed analyses of so called “post-and-core-systems” with respect to morphological characteristics of the resin-dentin interface in combination with bond strength measurements of fiber posts luted with these materials are scarce. The present study aimed to analyze four different post-and-core-systems with two different adhesive approaches (self-etch and etch-and-rinse). Materials and Methods Human anterior teeth (n = 80) were endodontically treated and post space preparations and post placement were performed using the following systems: Rebilda Post/Rebilda DC/Futurabond DC (Voco) (RB), Luxapost/Luxacore Z/Luxabond Prebond and Luxabond A+B (DMG) (LC), X Post/Core X Flow/XP Bond and Self Cure Activator (Dentsply DeTrey) (CX), FRC Postec/MultiCore Flow/AdheSE DC (Ivoclar Vivadent) (MC). Adhesive systems and core materials of 10 specimens per group were labeled using fluorescent dyes and resin-dentin interfaces were analyzed using Confocal Laser Scanning Microscopy (CLSM). Bond strengths were evaluated using a push-out test. Data were analyzed using repeated measurement ANOVA and following post-hoc test. Results CLSM analyses revealed significant differences between groups with respect to the factors hybrid layer thickness (p<0.0005) and number of resin tags (p = 0.02; ANOVA). Bond strength was significantly affected by core material (p = 0.001), location inside the root canal (p<0.0005) and incorporation of fluorescent dyes (p = 0.036; ANOVA). CX [7.7 (4.4) MPa] demonstrated significantly lower bond strength compared to LC [14.2 (8.7) MPa] and RB [13.3 (3.7) MPa] (p<0.05; Tukey HSD) but did not differ significantly from MC [11.5 (3.5) MPa]. Conclusion It can be concluded that bond strengths inside the root canal were not affected by the adhesive approach of the post-and-core-system. All systems demonstrated homogenous hybrid layer formation and penetration into the dentinal tubules in spite of the complicating conditions for adhesion inside the root canal. PMID:24586248
Advanced Biasing Experiments on the C-2 Field-Reversed Configuration Device
NASA Astrophysics Data System (ADS)
Thompson, Matthew; Korepanov, Sergey; Garate, Eusebio; Yang, Xiaokang; Gota, Hiroshi; Douglass, Jon; Allfrey, Ian; Valentine, Travis; Uchizono, Nolan; TAE Team
2014-10-01
The C-2 experiment seeks to study the evolution, heating and sustainment effects of neutral beam injection on field-reversed configuration (FRC) plasmas. Recently, substantial improvements in plasma performance were achieved through the application of edge biasing with coaxial plasma guns located in the divertors. Edge biasing provides rotation control that reduces instabilities and E × B shear that improves confinement. Typically, the plasma gun arcs are run at ~ 10 MW for the entire shot duration (~ 5 ms), which will become unsustainable as the plasma duration increases. We have conducted several advanced biasing experiments with reduced-average-power plasma gun operating modes and alternative biasing cathodes in an effort to develop an effective biasing scenario applicable to steady state FRC plasmas. Early results show that several techniques can potentially provide effective, long-duration edge biasing.
Fully-kinetic Ion Simulation of Global Electrostatic Turbulent Transport in C-2U
NASA Astrophysics Data System (ADS)
Fulton, Daniel; Lau, Calvin; Bao, Jian; Lin, Zhihong; Tajima, Toshiki; TAE Team
2017-10-01
Understanding the nature of particle and energy transport in field-reversed configuration (FRC) plasmas is a crucial step towards an FRC-based fusion reactor. The C-2U device at Tri Alpha Energy (TAE) achieved macroscopically stable plasmas and electron energy confinement time which scaled favorably with electron temperature. This success led to experimental and theoretical investigation of turbulence in C-2U, including gyrokinetic ion simulations with the Gyrokinetic Toroidal Code (GTC). A primary objective of TAE's new C-2W device is to explore transport scaling in an extended parameter regime. In concert with the C-2W experimental campaign, numerical efforts have also been extended in A New Code (ANC) to use fully-kinetic (FK) ions and a Vlasov-Poisson field solver. Global FK ion simulations are presented. Future code development is also discussed.
A microprocessor-controlled tracheal insufflation-assisted total liquid ventilation system.
Parker, James Courtney; Sakla, Adel; Donovan, Francis M; Beam, David; Chekuri, Annu; Al-Khatib, Mohammad; Hamm, Charles R; Eyal, Fabien G
2009-09-01
A prototype time cycled, constant volume, closed circuit perfluorocarbon (PFC) total liquid ventilator system is described. The system utilizes microcontroller-driven display and master control boards, gear motor pumps, and three-way solenoid valves to direct flow. A constant tidal volume and functional residual capacity (FRC) are maintained with feedback control using end-expiratory and end-inspiratory stop-flow pressures. The system can also provide a unique continuous perfusion (bias flow, tracheal insufflation) through one lumen of a double-lumen endotracheal catheter to increase washout of dead space liquid. FRC and arterial blood gases were maintained during ventilation with Rimar 101 PFC over 2-3 h in normal piglets and piglets with simulated pulmonary edema induced by instillation of albumin solution. Addition of tracheal insufflation flow significantly improved the blood gases and enhanced clearance of instilled albumin solution during simulated edema.
Formation of a field reversed configuration for magnetic and electrostatic confinement of plasma
Rostoker, Norman; Binderbauer, Michl
2003-12-16
A system and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions they are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.
Formation of a field reversed configuration for magnetic and electrostatic confinement of plasma
Rostoker, Norman; Binderbauer, Michl; Qerushi, Artan; Tahsiri, Hooshang
2007-02-20
A system and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions they are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.
Formation of a field reversed configuration for magnetic and electrostatic confinement of plasma
Rostoker, Norman; Binderbauer, Michl; Qerushi, Artan; Tahsiri, Hooshang
2006-02-07
A system and method for containing plasma and forming a Field Reversed Configuration (FRC) magnetic topology are described in which plasma ions are contained magnetically in stable, non-adiabatic orbits in the FRC. Further, the electrons are contained electrostatically in a deep energy well, created by tuning an externally applied magnetic field. The simultaneous electrostatic confinement of electrons and magnetic confinement of ions avoids anomalous transport and facilitates classical containment of both electrons and ions. In this configuration, ions and electrons may have adequate density and temperature so that upon collisions they are fused together by nuclear force, thus releasing fusion energy. Moreover, the fusion fuel plasmas that can be used with the present confinement system and method are not limited to neutronic fuels only, but also advantageously include advanced fuels.
NASA Astrophysics Data System (ADS)
Carlson, Arthur William
A measurement is reported which sets an upper bound on LHD-like density fluctuations in an FRC which is two orders of magnitude below the predicted levels. Particle loss from FRC's is known to occur anomalously fast, and this is usually attributed to effects of the LHD instability. If LHD waves are present, they can be measured using heterodyne detection of CO(,2) laser light scattered from the associated density fluctuations. In the present case, the usual scattering system was successfully modified to compensate for severe refraction of the beams by the plasma. This system was calibrated by detection of an electrooptically modulated CO(,2) laser beam, and by detection of light scattered from acoustic waves in salt. The plasma measurements made on the TRX-2 field-reversed theta-pinch covered all parameters at which LHD fluctuations might be expected to occur, namely wavenumbers from 30 to 240 cm('-1), frequencies from 10 to 300 MHz, and radii from one centimeter inside the separatrix to two centimeters outside. The lack of detectable scattered light under any of these conditions indicates ((delta)n/n) < 1 x 10('-4), compared to predictions of ((delta)n/n) ('(TURN)) 1 x 10('-2) based on mode coupling theory, ion -trapping theory, and observed transport rates. Several mechanisms are discussed which may stabilize LHD in these plasmas. Several alternate explanations of the observed anomalous transport rates in FRC's are also discussed.
NASA Astrophysics Data System (ADS)
Slough, J. T.; Hoffman, A. L.
1990-04-01
A high-order multipole ``barrier'' field was applied at the vacuum tube wall in the TRX experiment [Phys. Fluids B 1, 840 (1989)] during both the preionization and field reversal phases of field-reversed configuration (FRC) formation. Use of this field during field reversal resulted in a significant reduction of impurities as well as increased flux trapping. With a large enough Bθ at the wall, sheath detachment from the wall became apparent, and flux loss through the sheath became negligible (<10%). At larger wall Bθ (>1.5 kG), destructive rotational spin-up occurred, driven by Hall current forces. When the multipole barrier field was also applied during either axial discharge or ringing theta current preionization, a very symmetric and uniform breakdown of the fill gas was achieved. In particular, using ringing theta preionization, complete ionization of the fill gas was accomplished with purely inductive fields of remarkably low magnitude, where Ez≤3 V/cm, and Eθ≤20 V/cm. Due to the improved ionization symmetry, about 65% to 75% of the lift-off flux (flux remaining after field reversal) could be retained through the remaining formation processes into an equilibrium FRC. Using the multipole field during both preionization and formation, it was possible to form FRC's with good confinement with greater than 3 mWb of trapped flux at 15 mTorr D2 or H2 in a 10 cm radius device. Values of s in excess of 4 could be achieved in this manner.
High-beta spherical tokamak startup in TS-4 merging experiment by use of toroidal field ramp-up
NASA Astrophysics Data System (ADS)
Kaminou, Yasuhiro; , Toru, II; Kato, Joji; Inomoto, Michiaki; Ono, Yasushi; TS Group Team; National InstituteFusion Science Collaboration
2014-10-01
We demonstrated the formation method of an ultrahigh-beta spherical tokamak by use of a field-reversed configuration and a spheromak in TS-4 device (R ~ 0.5 m, A ~ 1.5, Ip ~ 30-100 kA, B ~ 100 mT). This method is composed of the following steps: 1. Two spheromaks are merged together and a high-beta spheromak or FRC is formed by reconnection heating. 2. External toroidal magnetic field is added (current rising time ~50 μs), and spherical tokamak-like configuration is formed. In this way, the ultrahigh-beta ST is formed. The ultrahigh-beta ST formed by FRC has a diamagnetic toroidal field, and it presumed to be in a second-stable state for ballooning stability, and the one formed by spheromak has a weak paramagnetic toroidal magnetic field, while a spheormak has a strong paramagnetic toroidal magnetic field. This diamagnetic current derives from inductive electric field by ramping up the external toroidal magnetic field, and the diamagnetic current sustains high thermal pressure of the ultrahigh-beta spherical tokamak. And the beta of the ultrahigh-beta ST formed by FRC reaches about 50%. To sustain the high-beta state, 0.6 MW neutral beam injection and center solenoid coils are installed to the TS-4 device. In the poster, we report the experimental results of ultrahigh-beta spherical tokamak startup and sustainment by NBI and CS current driving experiment.
Scaling Study of Reconnection Heating in Torus Plasma Merging Experiments
NASA Astrophysics Data System (ADS)
Ono, Yasushi; Akimitsu, Moe; Sawada, Asuka; Cao, Qinghong; Koike, Hideya; Hatano, Hironori; Kaneda, Taishi; Tanabe, Hiroshi
2017-10-01
We have been investigating toroidal plasma merging and reconnection for high-power heating of spherical tokamak (ST) and field-reversed configuration (FRC), using TS-3 (ST, FRC: R =0.2m, 1985-), TS-4 (ST, FRC: R =0.5m, 2000-), UTST (ST: R =0.45m, 2008-) and MAST (ST: R =0.9m, 2000-) devices. The series of merging experiments made clear the promising scaling and characteristics of reconnection heating: (i) its ion heating energy that scales with square of the reconnecting magnetic field Brec, (ii) its energy loss lower than 10%, (iii) its ion heating energy (in the downstream) 10 time larger than its electron heating energy (at around X-point) and (iv) low dependence of ion heating on the guide (toroidal) field Bg. The Brec2-scalingwas obtained when the current sheet was compressed to the order of ion gyrodadius. When the sheet was insufficiently compressed, the measured ion temperature was lower than the scaling prediction. Based on this scaling, we realized significant ion heating up to 1.2keV in MAST after 2D elucidation of ion heating up to 250eV in TS-3 [3,4]. This promising scaling leads us to new high Brec reconnection heating experiments for future direct access to burning plasma: TS-U (2017-) in Univ. Tokyo and ST-40 in Tokamak Energy Inc. (2017-). This presentation reviews major progresses in those toroidal plasma merging experiments for physics and fusion applications of magnetic reconnection.
Point-of-Purchase Labels and Reward Cards Improve Sales of Healthy Foods in University Dining Halls.
Biden, Catherine R; Matthews, June I; Laframboise, Natalie A; Zok, Anne; Dworatzek, Paula D N; Seabrook, Jamie A
2018-06-12
To compare sales of Food Resources and Education for Student Health (FRESH) Approved versus non-FRESH Approved menu cycle items pre- and postimplementation of the FRESH program. Sales data from 2011-2015 of FRESH Approved versus non-FRESH Approved menu items were analyzed. Fruit and milk items sold, net sales, and the cost of free fruit and milk redeemed through the FRESH Reward Card (FRC) program, were also analyzed. FRESH Approved items sold more often than non-FRESH Approved items in the latter 2 years (P = 0.01). Prices of FRESH Approved menu items were significantly lower than non-FRESH Approved items for all years (e.g., $1.52 ± $0.94 vs $2.21 ± $1.02 per serving in 2014-2015; P < 0.001). Across all FRESH implementation years, FRESH Approved menu items were found more often on the 6-week menu (P < 0.05). The number of fruit items sold increased from a baseline of 143 052 to 170 954, and net sales increased from $135 450 to $154 248 after 3 years of the FRC implementation. FRESH Approved items were less expensive, available more often, and had higher sales. The FRC increased net fruit sales despite the cost of free fruit. Highlighting and reducing the cost of healthy foods are promising practices to improve campus food environments.
Should PEEP Titration Be Based on Chest Mechanics in Patients With ARDS?
Kallet, Richard H
2016-06-01
Functional residual capacity (FRC) is essentially the alveolar volume and a determinant of both oxygenation and respiratory system compliance (CRS). ARDS decreases FRC, and sufficient PEEP restores FRC; thus, assessments of PEEP by its impact on oxygenation and CRS are intimately linked. PEEP also can ameliorate or aggravate ventilator-induced lung injury. Therefore, it can be argued that PEEP should be titrated primarily by its impact on CRS The pro position argues that the heterogeneous nature of lung injury and its unique presentation in individual patients results in an uncoupling between oxygenation and CRS Therefore, relying upon oxygenation alone may enhance lung injury and mortality risk, particularly in those with severe ARDS. The con argument is that the preponderance of preclinical and clinical evidence suggests that a relatively narrow range of PEEP is required to manage all but the most severe cases of ARDS. In addition, pathological alterations in chest wall compliance confuse the interpretation of chest mechanics. Moreover, ambiguities and technical limitations in advanced techniques, such as esophageal manometry and pressure-volume curves, add a layer of complexity that renders its broader application in all ARDS patients both impractical and unnecessary. Whether sophisticated monitoring of chest mechanics in severe ARDS might improve outcomes further is open to question and should be studied further. However, it is highly improbable that we will ever discover a PEEP strategy that optimizes all aspects of cardiorespiratory function and chest mechanics for individual patients suffering from ARDS. Copyright © 2016 by Daedalus Enterprises.
Rocca, Giovanni Tommaso; Saratti, Carlo Massimo; Poncet, Antoine; Feilzer, Albert J; Krejci, Ivo
2016-05-01
To evaluate the marginal adaptation of endodontically treated molars restored with CAD/CAM composite resin endocrowns either with or without reinforcement by fibre reinforced composites (FRCs), used in different configurations. 32 human endodontically treated molars were cut 2 mm over the CEJ. Two interproximal boxes were created with the margins located 1 mm below the CEJ (distal box) and 1 mm over the CEJ (mesial box). All specimens were divided in four groups (n = 8). The pulp chamber was filled with: group 1 (control), hybrid resin composite (G-aenial Posterior, GC); group 2, as group 1 but covered by 3 meshes of E-glass fibres (EverStick NET, Stick Tech); group 3, FRC resin (EverX Posterior, GC); group 4, as group 3 but covered by 3 meshes of E-glass fibres. The crowns of all teeth were restored with CAD/CAM composite resin endocrowns (LAVA Ultimate, 3M). All specimens were thermo-mechanically loaded in a computer-controlled chewing machine (600,000 cycles, 1.6 Hz, 49 N and simultaneously 1500 thermo-cycles, 60 s, 5-55 °C). Marginal analysis before and after the loading was carried out on epoxy replicas by SEM at 200× magnification. For all the groups, the percentage values of perfect marginal adaptation after loading were always significantly lower than before loading (p < 0.05). The marginal adaptation before and after loading was not significantly different between the experimental groups (p > 0.05). Within the limitations of this in vitro study, the use of FRCs to reinforce the pulp chamber of devitalized molars restored with CAD/CAM composite resin restorations did not significantly influenced their marginal quality.
Load-bearing capacity of human incisor restored with various fiber-reinforced composite posts.
Le Bell-Rönnlöf, Anna-Maria; Lassila, Lippo V J; Kangasniemi, Ilkka; Vallittu, Pekka K
2011-06-01
The aim of this study was to evaluate the load-bearing capacity and microstrain of incisors restored with posts of various kinds. Both prefabricated titanium posts and different fiber-reinforced composite posts were tested. The crowns of human incisors were cut and post preparation was carried out. The roots were divided into groups: (1) prefabricated serrated titanium posts, (2) prefabricated carbon fiber-reinforced composite posts, (3) individually formed glass fiber-reinforced composite posts with the canal full of fibers, and (4) individually formed "split" glass fiber-reinforced composite posts. The posts were cemented and composite crowns were made. Intact human incisors were used as reference. All roots were embedded in acrylic resin cylinders and stored at room temperature in water. Static load was applied under a loading angle of 45° using a universal testing machine. On half of the specimens microstrain was measured with strain gages and an acoustic emission analysis was carried out. Failure mode assessment was also made. The group with titanium posts showed highest number of unfavorable failures compared to the groups with fiber-reinforced composite posts. With fiber-reinforced composite posts the failures may more often be favorable compared to titanium posts, which clinically means repairable failures. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
2017-09-01
9th international conference on fibre reinforced concretes (FRC), textile reinforced concretes (TRC) and ultra-high performance concretes (UHPC) Preface The Fibre Concrete Conference series is held biennially to provide a platform to share knowledge on fibre reinforced concretes, textile concretes and ultra-high performance concretes regarding material properties and behaviour, technology procedures, topics of long-term behaviour, creep, durability; sustainable aspects of concrete including utilisation of waste materials in concrete production and recycling of concrete. The tradition of Fibre Concrete Conferences started in eighties of the last century. Nowadays the conference is organized by the Department of Concrete and Masonry Structures of the Czech Technical University in Prague, Faculty of Civil Engineering. The 9th International Conference Fibre Concrete 2017 had 109 participants from 27 countries all over the world. 55 papers were presented including keynote lectures of Professor Bažant, Professor Bartoš and Dr. Broukalová. The conference program covered wide range of topics from scientific research to practical applications. The presented contributions related to performance and behaviour of cement based composites, their long-term behaviour and durability, sustainable aspects, advanced analyses of structures from these composites and successful applications. This conference was organized also to honour Professor Zděnek P. Bažant on the occasion of his jubilee and to appreciate his merits and discoveries in the field of fibre reinforced composites, structural mechanics and engineering.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen Zhu
2006-06-15
High-Resolution Mineralogical Characterization and Biogeochemical Modeling of Uranium Reduction Pathways at the Oak Ridge Field-Research Center (FRC) Chen Zhu, Indiana University, David R. Veblen, Johns Hopkins University We have successfully completed a proof-of-concept, one-year grant on a three-year proposal from the former NABIR program, and here we seek additional two-year funding to complete and publish the research. Using a state-of-the-art 300-kV, atomic resolution, Field Emission Gun Transmission Electron Microscope (TEM), we have successfully identified three categories of mineral hosts for uranium in contaminated soils: (1) iron oxides; (2) mixed manganese-iron oxides; and (3) uranium phosphates. Method development using parallel electronmore » energy loss spectroscopy (EELS) associated with the TEM shows great promise for characterizing the valence states of immobilized U during bioremediation. We have also collected 27 groundwater samples from two push-pull field biostimulation tests, which form two time series from zero to approximately 600 hours. The temporal evolution in major cations, anions, trace elements, and the stable isotopes 34S, 18O in sulfate, 15N in nitrate, and 13C in dissolved inorganic carbon (DIC) clearly show that biostimulation resulted in reduction of nitrate, Mn(IV), Fe(III), U(VI), sulfate, and Tc(VII), and these reduction reactions were intimately coupled with a complex network of inorganic reactions evident from alkalinity, pH, Na, K, Mg, and Ca concentrations. From these temporal trends, apparent zero order rates were regressed. However, our extensive suite of chemical and isotopic data sets, perhaps the first and only comprehensive data set available at the FRC, show that the derived rates from these field biostimulation experiments are composite and lump-sum rates. There were several reactions that were occurring at the same time but were masked by these pseudo-zero order rates. A reaction-path model comprising a total of nine redox couples (NO3–/NH4+, MnO2(s)/Mn2+, Fe(OH)3(s) /Fe2+, TcO4–/TcO2(s), UO22+/UO2(s), SO42–/HS–, CO2/CH4, ethanol/acetate, and H+/H2.) is used to simulate the temporal biogeochemical evolution observed in the field tests. Preliminary results show that the models based on thermodynamics and more complex rate laws can generate the apparent zero order rates when several concurrent or competing reactions occur. Professor Alex Halliday of Oxford University, UK, and his postdoctoral associates are measuring the uranium isotopes in our groundwater samples. Newly developed state-of-the-art analytical techniques in measuring variability in 235U/238U offer the potential to distinguish biotic and abiotic uranium reductive mechanisms.« less
The effect of lung deformation on the spatial distribution of pulmonary blood flow.
Arai, Tatsuya J; Theilmann, Rebecca J; Sá, Rui Carlos; Villongco, Michael T; Hopkins, Susan R
2016-11-01
Pulmonary perfusion measurement using magnetic resonance imaging combined with deformable image registration enabled us to quantify the change in the spatial distribution of pulmonary perfusion at different lung volumes. The current study elucidated the effects of tidal volume lung inflation [functional residual capacity (FRC) + 500 ml and FRC + 1 litre] on the change in pulmonary perfusion distribution. Changes in hydrostatic pressure distribution as well as transmural pressure distribution due to the change in lung height with tidal volume inflation are probably bigger contributors to the redistribution of pulmonary perfusion than the changes in pulmonary vasculature resistance caused by lung tissue stretch. Tidal volume lung inflation results in structural changes in the pulmonary circulation, potentially affecting pulmonary perfusion. We hypothesized that perfusion is recruited to regions receiving the greatest deformation from a tidal breath, thus ensuring ventilation-perfusion matching. Density-normalized perfusion (DNP) magnetic resonance imaging data were obtained in healthy subjects (n = 7) in the right lung at functional residual capacity (FRC), FRC+500 ml, and FRC+1.0 l. Using deformable image registration, the displacement of a sagittal lung slice acquired at FRC to the larger volumes was calculated. Registered DNP images were normalized by the mean to estimate perfusion redistribution (nDNP). Data were evaluated across gravitational regions (dependent, middle, non-dependent) and by lobes (upper, RUL; middle, RML; lower, RLL). Lung inflation did not alter mean DNP within the slice (P = 0.10). The greatest expansion was seen in the dependent region (P < 0.0001: dependent vs non-dependent, P < 0.0001: dependent vs middle) and RLL (P = 0.0015: RLL vs RUL, P < 0.0001: RLL vs RML). Neither nDNP recruitment to RLL [+500 ml = -0.047(0.145), +1 litre = 0.018(0.096)] nor to dependent lung [+500 ml = -0.058(0.126), +1 litre = -0.023(0.106)] were found. Instead, redistribution was seen in decreased nDNP in the non-dependent [+500 ml = -0.075(0.152), +1 litre = -0.137(0.167)) and increased nDNP in the gravitational middle lung [+500 ml = 0.098(0.058), +1 litre = 0.093(0.081)] (P = 0.01). However, there was no significant lobar redistribution (P < 0.89). Contrary to our hypothesis, based on the comparison between gravitational and lobar perfusion data, perfusion was not redistributed to the regions of the most inflation. This suggests that either changes in hydrostatic pressure or transmural pressure distribution in the gravitational direction are implicated in the redistribution of perfusion away from the non-dependent lung. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.
The effect of lung deformation on the spatial distribution of pulmonary blood flow
Arai, Tatsuya J.; Theilmann, Rebecca J.; Sá, Rui Carlos; Villongco, Michael T.
2016-01-01
Key points Pulmonary perfusion measurement using magnetic resonance imaging combined with deformable image registration enabled us to quantify the change in the spatial distribution of pulmonary perfusion at different lung volumes.The current study elucidated the effects of tidal volume lung inflation [functional residual capacity (FRC) + 500 ml and FRC + 1 litre] on the change in pulmonary perfusion distribution.Changes in hydrostatic pressure distribution as well as transmural pressure distribution due to the change in lung height with tidal volume inflation are probably bigger contributors to the redistribution of pulmonary perfusion than the changes in pulmonary vasculature resistance caused by lung tissue stretch. Abstract Tidal volume lung inflation results in structural changes in the pulmonary circulation, potentially affecting pulmonary perfusion. We hypothesized that perfusion is recruited to regions receiving the greatest deformation from a tidal breath, thus ensuring ventilation–perfusion matching. Density‐normalized perfusion (DNP) magnetic resonance imaging data were obtained in healthy subjects (n = 7) in the right lung at functional residual capacity (FRC), FRC+500 ml, and FRC+1.0 l. Using deformable image registration, the displacement of a sagittal lung slice acquired at FRC to the larger volumes was calculated. Registered DNP images were normalized by the mean to estimate perfusion redistribution (nDNP). Data were evaluated across gravitational regions (dependent, middle, non‐dependent) and by lobes (upper, RUL; middle, RML; lower, RLL). Lung inflation did not alter mean DNP within the slice (P = 0.10). The greatest expansion was seen in the dependent region (P < 0.0001: dependent vs non‐dependent, P < 0.0001: dependent vs middle) and RLL (P = 0.0015: RLL vs RUL, P < 0.0001: RLL vs RML). Neither nDNP recruitment to RLL [+500 ml = −0.047(0.145), +1 litre = 0.018(0.096)] nor to dependent lung [+500 ml = −0.058(0.126), +1 litre = −0.023(0.106)] were found. Instead, redistribution was seen in decreased nDNP in the non‐dependent [+500 ml = −0.075(0.152), +1 litre = −0.137(0.167)) and increased nDNP in the gravitational middle lung [+500 ml = 0.098(0.058), +1 litre = 0.093(0.081)] (P = 0.01). However, there was no significant lobar redistribution (P < 0.89). Contrary to our hypothesis, based on the comparison between gravitational and lobar perfusion data, perfusion was not redistributed to the regions of the most inflation. This suggests that either changes in hydrostatic pressure or transmural pressure distribution in the gravitational direction are implicated in the redistribution of perfusion away from the non‐dependent lung. PMID:27273807
DOT National Transportation Integrated Search
2013-05-01
This report showcases several new approaches of using materials science and structural mechanics to accomplish : sustainable design of concrete materials. The topics addressed include blended cements, fiber-reinforced concrete : (FRC), internal curin...
Performance improvement of magnetized coaxial plasma gun by magnetic circuit on a bias coil
NASA Astrophysics Data System (ADS)
Edo, Takahiro; Matsumoto, Tadafumi; Asai, Tomohiko; Kamino, Yasuhiro; Inomoto, Michiaki; Gota, Hiroshi
2016-10-01
A magnetized coaxial plasmoid accelerator has been utilized for compact torus (CT) injection to refuel into fusion reactor core plasma. Recently, CT injection experiments have been conducted on the C-2/C-2U facility at Tri Alpha Energy. In the series of experiments successful refueling, i.e. increased particle inventory of field-reversed configuration (FRC) plasma, has been observed. In order to improve the performance of CT injector and to refuel in the upgraded FRC device, called C-2W, with higher confinement magnetic field, magnetic circuit consisting of magnetic material onto a bias magnetic coil is currently being tested at Nihon University. Numerical work suggests that the optimized bias magnetic field distribution realizes the increased injection velocity because of higher conversion efficiency of Lorenz self force to kinetic energy. Details of the magnetic circuit design as well as results of the test experiment and field calculations will be presented and discussed.
The Pulsed High Density Experiment (PHDX) Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slough, John P.; Andreason, Samuel
The purpose of this paper is to present the conclusions that can be drawn from the Field Reversed Configuration (FRC) formation experiments conducted on the Pulsed High Density experiment (PHD) at the University of Washington. The experiment is ongoing. The experimental goal for this first stage of PHD was to generate a stable, high flux (>10 mWb), high energy (>10 KJ) target FRC. Such results would be adequate as a starting point for several later experiments. This work focuses on experimental implementation and the results of the first four month run. Difficulties were encountered due to the initial on-axis plasmamore » ionization source. Flux trapping with this ionization source acting alone was insufficient to accomplish experimental objectives. Additional ionization methods were utilized to overcome this difficulty. A more ideal plasma source layout is suggested and will be explored during a forthcoming work.« less
NASA Astrophysics Data System (ADS)
Carlson, Arthur W.
1987-05-01
An upper bound of (ñe/ne) <10-4 for frequencies and wavenumbers relevant to the lower-hybrid-drift (LHD) instability is set on fluctuations in field-reversed configurations (FRC's) produced by TRX-2 [Fusion Techn. 9, 48 (1986)]. LHD is a well-studied microinstability that is often invoked to explain particle loss rates in FRC's. The conventional technique of CO2 laser scattering with heterodyne detection is here modified to compensate for severe refraction. The calibration of the system is verified by scattering from acoustic waves in salt. The measured bound is two orders of magnitude below both the fluctuation level usually predicted and the level needed to account for observed particle loss rates. Electron collisionality is identified as the most likely LHD stabilization mechanism. Some alternative explanations of anomalous loss rates are discussed.
Absolute calibration of neutron detectors on the C-2U advanced beam-driven FRC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magee, R. M., E-mail: rmagee@trialphaenergy.com; Clary, R.; Korepanov, S.
2016-11-15
In the C-2U fusion energy experiment, high power neutral beam injection creates a large fast ion population that sustains a field-reversed configuration (FRC) plasma. The diagnosis of the fast ion pressure in these high-performance plasmas is therefore critical, and the measurement of the flux of neutrons from the deuterium-deuterium (D-D) fusion reaction is well suited to the task. Here we describe the absolute, in situ calibration of scintillation neutron detectors via two independent methods: firing deuterium beams into a high density gas target and calibration with a 2 × 10{sup 7} n/s AmBe source. The practical issues of each methodmore » are discussed and the resulting calibration factors are shown to be in good agreement. Finally, the calibration factor is applied to C-2U experimental data where the measured neutron rate is found to exceed the classical expectation.« less
Introduction to D-He(3) fusion reactors
NASA Technical Reports Server (NTRS)
Vlases, G. C.; Steinhauer, L. C.
1989-01-01
A review and evaluation of D-He(3) fusion reactor technology is presented. The advantages and disadvantages of the D-He(3) and D-T reactor cycles are outlined and compared. In addition, the general design features of D-He(3) tokamaks and field reversed configuration (FRC) reactors are described and the relative merits of each are compared. It is concluded that both tokamaks and FRC's offer certain advantages, and that the ultimate decision as to which to persue for terrestrial power generation will depend heavily on how the physics performance of each of them develops over the next few years. It is clear that the D-He(3) fuel cycle offers marked advantages over the D-T cycle. Although the physics requirements for D-He(3) are more demanding, the overwhelming advantages resulting from the two order of magnitude reduction of neutron flux are expected to lead to a shorter time to commercialization than for the D-T cycle.
Cardiopulmonary readjustments in passive tilt
NASA Technical Reports Server (NTRS)
Matalon, S. V.; Farhi, L. E.
1979-01-01
The readjustment of cardiopulmonary variables in human volunteers at various tilt angles on a tilt board is studied. Five healthy subjects (18-31 yr) with thorough knowledge of the experimental protocol are tested, passively tilted from the supine to the upright position in 15-deg increments in random sequence. The parameters measured are cardiac output (Q), heart rate (HR), stroke volume (SV), minute and alveolar ventilation /V(E) and V(A)/, functional residual capacity (FRC), and arterial-end-tidal P(CO2) pressure difference. It is found that changes in Q and FRC are linearly related to the sine of the tilt angle, indicating that either reflexes are absent or their net effect is proportional to the effects of gravity. This is clearly not the case for other variables /HR, SV, V(E), V(A)/, where it is possible to demonstrate threshold values for the appearance of secondary changes.
Cost Modeling and Design of Field-Reversed Configuration Fusion Power Plants
NASA Astrophysics Data System (ADS)
Kirtley, David; Slough, John; Helion Team
2017-10-01
The Inductively Driven Liner (IDL) fusion concept uses the magnetically driven implosion of thin (0.5-1 mm) Aluminum hoops to magnetically compress a merged Field-Reversed Configuration (FRC) plasma to fusion conditions. Both the driver and the target have been studied experimentally and theoretically by researchers at Helion Energy, MSNW, and the University of Washington, demonstrating compression fields greater than 100 T and suitable fusion targets. In the presented study, a notional power plant facility using this approach will be described. In addition, a full cost study based on the LLNL Z-IFE and HYLIFE-II studies, the ARIES Tokamak concept, and RAND power plant studies will be described. Finally, the expected capital costs, development requirements, and LCOE for 50 and 500 MW power plants will be given. This analysis includes core FRC plant scaling, metallic liner recycling, radiation shielding, operations, and facilities capital requirements.
Introduction to D-He(3) fusion reactors
NASA Astrophysics Data System (ADS)
Vlases, G. C.; Steinhauer, L. C.
1989-07-01
A review and evaluation of D-He(3) fusion reactor technology is presented. The advantages and disadvantages of the D-He(3) and D-T reactor cycles are outlined and compared. In addition, the general design features of D-He(3) tokamaks and field reversed configuration (FRC) reactors are described and the relative merits of each are compared. It is concluded that both tokamaks and FRC's offer certain advantages, and that the ultimate decision as to which to persue for terrestrial power generation will depend heavily on how the physics performance of each of them develops over the next few years. It is clear that the D-He(3) fuel cycle offers marked advantages over the D-T cycle. Although the physics requirements for D-He(3) are more demanding, the overwhelming advantages resulting from the two order of magnitude reduction of neutron flux are expected to lead to a shorter time to commercialization than for the D-T cycle.
Absolute calibration of neutron detectors on the C-2U advanced beam-driven FRC.
Magee, R M; Clary, R; Korepanov, S; Jauregui, F; Allfrey, I; Garate, E; Valentine, T; Smirnov, A
2016-11-01
In the C-2U fusion energy experiment, high power neutral beam injection creates a large fast ion population that sustains a field-reversed configuration (FRC) plasma. The diagnosis of the fast ion pressure in these high-performance plasmas is therefore critical, and the measurement of the flux of neutrons from the deuterium-deuterium (D-D) fusion reaction is well suited to the task. Here we describe the absolute, in situ calibration of scintillation neutron detectors via two independent methods: firing deuterium beams into a high density gas target and calibration with a 2 × 10 7 n/s AmBe source. The practical issues of each method are discussed and the resulting calibration factors are shown to be in good agreement. Finally, the calibration factor is applied to C-2U experimental data where the measured neutron rate is found to exceed the classical expectation.
Comparing de novo genome assembly: the long and short of it.
Narzisi, Giuseppe; Mishra, Bud
2011-04-29
Recent advances in DNA sequencing technology and their focal role in Genome Wide Association Studies (GWAS) have rekindled a growing interest in the whole-genome sequence assembly (WGSA) problem, thereby, inundating the field with a plethora of new formalizations, algorithms, heuristics and implementations. And yet, scant attention has been paid to comparative assessments of these assemblers' quality and accuracy. No commonly accepted and standardized method for comparison exists yet. Even worse, widely used metrics to compare the assembled sequences emphasize only size, poorly capturing the contig quality and accuracy. This paper addresses these concerns: it highlights common anomalies in assembly accuracy through a rigorous study of several assemblers, compared under both standard metrics (N50, coverage, contig sizes, etc.) as well as a more comprehensive metric (Feature-Response Curves, FRC) that is introduced here; FRC transparently captures the trade-offs between contigs' quality against their sizes. For this purpose, most of the publicly available major sequence assemblers--both for low-coverage long (Sanger) and high-coverage short (Illumina) reads technologies--are compared. These assemblers are applied to microbial (Escherichia coli, Brucella, Wolbachia, Staphylococcus, Helicobacter) and partial human genome sequences (Chr. Y), using sequence reads of various read-lengths, coverages, accuracies, and with and without mate-pairs. It is hoped that, based on these evaluations, computational biologists will identify innovative sequence assembly paradigms, bioinformaticists will determine promising approaches for developing "next-generation" assemblers, and biotechnologists will formulate more meaningful design desiderata for sequencing technology platforms. A new software tool for computing the FRC metric has been developed and is available through the AMOS open-source consortium.
Nielsen, Niklas; Nielsen, Jorgen G.; Horsley, Alex R.
2013-01-01
Background A large body of evidence has now accumulated describing the advantages of multiple breath washout tests over conventional spirometry in cystic fibrosis (CF). Although the majority of studies have used exogenous sulphur hexafluoride (SF6) as the tracer gas this has also led to an increased interest in nitrogen washout tests, despite the differences between these methods. The impact of body nitrogen excreted across the alveoli has previously been ignored. Methods A two-compartment lung model was developed that included ventilation heterogeneity and dead space (DS) effects, but also incorporated experimental data on nitrogen excretion. The model was used to assess the impact of nitrogen excretion on washout progress and accuracy of functional residual capacity (FRC) and lung clearance index (LCI) measurements. Results Excreted nitrogen had a small effect on accuracy of FRC (1.8%) in the healthy adult model. The error in LCI calculated with true FRC was greater (6.3%), and excreted nitrogen contributed 21% of the total nitrogen concentration at the end of the washout. Increasing DS and ventilation heterogeneity both caused further increase in measurement error. LCI was increased by 6–13% in a CF child model, and excreted nitrogen increased the end of washout nitrogen concentration by 24–49%. Conclusions Excreted nitrogen appears to have complex but clinically significant effects on washout progress, particularly in the presence of abnormal gas mixing. This may explain much of the previously described differences in washout outcomes between SF6 and nitrogen. PMID:24039916
Light exaggerates apical hook curvature through phytochrome actions in tomato seedlings.
Shichijo, Chizuko; Ohuchi, Hisako; Iwata, Naoko; Nagatoshi, Yukari; Takahashi, Miki; Nakatani, Eri; Inoue, Kentaroh; Tsurumi, Seiji; Tanaka, Osamu; Hashimoto, Tohru
2010-02-01
Contrary to the established notion that the apical hook of dark-grown dicotyledonous seedlings opens in response to light, we found in tomato (Solanum lycopersicum L.) that the apical hook curvature is exaggerated by light. Experiments with several tomato cultivars and phytochrome mutants, irradiated with red and far-red light either as a brief pulse (Rp, FRp) or continuously (Rc, FRc), revealed: the hook-exaggeration response is maximal at the emergence of the hypocotyl from the seed; the effect of Rp is FRp-reversible; fluence-response curves to a single Rp or FRp show an involvement of low and very low fluence responses (LFR, VLFR); the effect of Rc is fluence-rate dependent, but that of FRc is not; the phyA mutant (phyA hp-1) failed to respond to an Rp of less than 10(-2) micromol m(-2) and to an FRp of all fluences tested as well as to FRc, thus indicating that the hook-exaggeration response involves phyA-mediated VLFR. The Rp fluence-response curve with the same mutant also confirmed the presence of an LFR mediated by phytochrome(s) other than phyA, although the phyB1 mutant (phyB1 hp-1) still showed full response probably due to other redundant phytochrome species (e.g., phyB2). Simulation experiments led to the possible significance of hook exaggeration in the field that the photoresponse may facilitate the release of seed coat when seeds germinate at some range of depth in soil. It was also observed that seed coat and/or endosperm are essential to the hook exaggeration.
Benkhatar, Hakim; Khettab, Idir; Sultanik, Philippe; Laccourreye, Ollivier; Bonfils, Pierre
2018-08-01
To determine the frontal sinus revision rate after nasal polyposis (NP) surgery including frontal recess clearance (FRC) and middle turbinectomy (MT), to search for predictive factors and to analyse surgical management. Longitudinal analysis of 153 patients who consecutively underwent bilateral sphenoethmoidectomy with FRC and MT for NP with a minimum follow-up of 7 years. Decision of revision surgery was made in case of medically refractory chronic frontal sinusitis or frontal mucocele. Univariate and multivariate analysis incorporating clinical and radiological variables were performed. The frontal sinus revision rate was 6.5% (10/153). The mean time between the initial procedure and revision surgery was 3 years, 10 months. Osteitis around the frontal sinus outflow tract (FSOT) was associated with a higher risk of frontal sinus revision surgery (p=0.01). Asthma and aspirin intolerance did not increase the risk, as well as frontal sinus ostium diameter or residual frontoethmoid cells. Among revised patients, 60% required multiple procedures and 70% required frontal sinus ostium enlargement. Our long-term study reports that NP surgery including FRC and MT is associated with a low frontal sinus revision rate (6.5%). Patients developing osteitis around the FSOT have a higher risk of frontal sinus revision surgery. As mucosal damage can lead to osteitis, FSOT mucosa should be preserved during initial NP surgery. However, as multiple procedures are common among NP patients requiring frontal sinus revision, frontal sinus ostium enlargement should be considered during first revision in the hope of reducing the need of further revisions. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rognlien, T. D.; Cohen, B. I.
This report describes work performed by LLNL to model the behavior and performance of a reverse-field configuration (FRC) type of plasma device as a plasma thruster as summarized by Razin et al. [1], which also describes the MNX device at PPPL used to study this concept.
Gowda, Srinivasa; Quadras, Dilip D; Sesappa, Shetty R; Maiya, G R Ramakrishna; Kumar, Lalit; Kulkarni, Dinraj; Mishra, Nitu
2018-05-01
The aim of the study was to evaluate the fracture strength of three types of composite core build-up materials. The objectives were to study and evaluate the fracture strength and type of fracture in composite core build-up in restoration of endodonti-cally treated teeth with or without a prefabricated metallic post. A total of 60 freshly extracted mandibular premolars free of caries, cracks, or fractures were end-odontically treated and restored with composite core build-up with prefabricated metallic posts cemented with resin luting cement (group I) and without a post (group II). This was followed by a core build-up of 10 teeth each with three different types of composite materials: Hybrid composite, nanocomposite, and ormocer respectively. The samples were mounted on polyvinyl chloride block and then loaded in the universal load frame at 90° to the long axis of tooth. The fracture strength of the samples was directly obtained from the load indicator attached to the universal load frame. Analysis of variance (ANOVA) test revealed that teeth restored with post exhibited highest fracture strength (1552.32 N) and teeth restored without post exhibited lowest fracture strength (232.20 N). Bonferroni's test revealed that values for hybrid composite (Z-100, 3M ESPE) with post, nanocomposite (Z-350, 3M ESPE) with post, ormocer composite (Admira-VOCO) with post, and nanocomposite (Z-350, 3M ESPE) without post were not significantly different from each other. Teeth restored with post and core using hybrid composite yielded the highest values for fracture strength. Teeth restored with ormocer core without post exhibited the lowest values. Teeth restored with nanocomposite core without post exhibited strength that was comparable with hybrid composite core but higher than that of ormocer. Mutilated endodontically treated teeth can be prosthetically rehabilitated successfully by using adhesive composite core build-up along with post to meet anatomical, functional, and esthetic demands.
Comparison of the retention of 5 core materials supported by a dental post.
Gu, Steven; Isidro, Mario; Deutsch, Allan S; Musikant, Barry L
2006-01-01
This study evaluated the retention of dental post heads (No. 2 Flexi-Post) embedded in 5 core materials (1 automix resin composite, 2 hand-mixed resin composites, and 2 glass ionomers). Samples were prepared by embedding post heads in 4.5-mm-thick disks of core material. The resin composite materials provided significantly more retention than the glass-ionomer-based materials. The post head retention of the automix resin composite was comparable to that of the hand-mixed resin composites. Unlike the resin composite samples, all the glass-ionomer samples fractured during testing. This is an unacceptable condition for a clinically successful restoration.
RF Plasma Heating in the PFRC-2 Device: Motivation, Goals and Methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cohen, S.; Brunkhorst, C.; Glasser, A.
2011-12-23
The motivation for using radio frequency, odd-parity rotating magnetic fields for heating field-reversed-configuration (FRC) plasmas is explained. Calculations are presented of the expected electron and ion temperatures in the PFRC-2 device, currently under construction.
Choi, Sanghun; Hoffman, Eric A; Wenzel, Sally E; Castro, Mario; Lin, Ching-Long
2014-09-15
Lung air trapping is estimated via quantitative computed tomography (CT) using density threshold-based measures on an expiration scan. However, the effects of scanner differences and imaging protocol adherence on quantitative assessment are known to be problematic. This study investigates the effects of protocol differences, such as using different CT scanners and breath-hold coaches in a multicenter asthmatic study, and proposes new methods that can adjust intersite and intersubject variations. CT images of 50 healthy subjects and 42 nonsevere and 52 severe asthmatics at total lung capacity (TLC) and functional residual capacity (FRC) were acquired using three different scanners and two different coaching methods at three institutions. A fraction threshold-based approach based on the corrected Hounsfield unit of air with tracheal density was applied to quantify air trapping at FRC. The new air-trapping method was enhanced by adding a lung-shaped metric at TLC and the lobar ratio of air-volume change between TLC and FRC. The fraction-based air-trapping method is able to collapse air-trapping data of respective populations into distinct regression lines. Relative to a constant value-based clustering scheme, the slope-based clustering scheme shows the improved performance and reduced misclassification rate of healthy subjects. Furthermore, both lung shape and air-volume change are found to be discriminant variables for differentiating among three populations of healthy subjects and nonsevere and severe asthmatics. In conjunction with the lung shape and air-volume change, the fraction-based measure of air trapping enables differentiation of severe asthmatics from nonsevere asthmatics and nonsevere asthmatics from healthy subjects, critical for the development and evaluation of new therapeutic interventions. Copyright © 2014 the American Physiological Society.
Choi, Sanghun; Hoffman, Eric A.; Wenzel, Sally E.; Castro, Mario
2014-01-01
Lung air trapping is estimated via quantitative computed tomography (CT) using density threshold-based measures on an expiration scan. However, the effects of scanner differences and imaging protocol adherence on quantitative assessment are known to be problematic. This study investigates the effects of protocol differences, such as using different CT scanners and breath-hold coaches in a multicenter asthmatic study, and proposes new methods that can adjust intersite and intersubject variations. CT images of 50 healthy subjects and 42 nonsevere and 52 severe asthmatics at total lung capacity (TLC) and functional residual capacity (FRC) were acquired using three different scanners and two different coaching methods at three institutions. A fraction threshold-based approach based on the corrected Hounsfield unit of air with tracheal density was applied to quantify air trapping at FRC. The new air-trapping method was enhanced by adding a lung-shaped metric at TLC and the lobar ratio of air-volume change between TLC and FRC. The fraction-based air-trapping method is able to collapse air-trapping data of respective populations into distinct regression lines. Relative to a constant value-based clustering scheme, the slope-based clustering scheme shows the improved performance and reduced misclassification rate of healthy subjects. Furthermore, both lung shape and air-volume change are found to be discriminant variables for differentiating among three populations of healthy subjects and nonsevere and severe asthmatics. In conjunction with the lung shape and air-volume change, the fraction-based measure of air trapping enables differentiation of severe asthmatics from nonsevere asthmatics and nonsevere asthmatics from healthy subjects, critical for the development and evaluation of new therapeutic interventions. PMID:25103972
Influence of heart failure on resting lung volumes in patients with COPD
de Souza, Aline Soares; Sperandio, Priscila Abreu; Mazzuco, Adriana; Alencar, Maria Clara; Arbex, Flávio Ferlin; de Oliveira, Mayron Faria; O'Donnell, Denis Eunan; Neder, José Alberto
2016-01-01
ABSTRACT Objective: To evaluate the influence of chronic heart failure (CHF) on resting lung volumes in patients with COPD, i.e., inspiratory fraction-inspiratory capacity (IC)/TLC-and relative inspiratory reserve-[1 − (end-inspiratory lung volume/TLC)]. Methods: This was a prospective study involving 56 patients with COPD-24 (23 males/1 female) with COPD+CHF and 32 (28 males/4 females) with COPD only-who, after careful clinical stabilization, underwent spirometry (with forced and slow maneuvers) and whole-body plethysmography. Results: Although FEV1, as well as the FEV1/FVC and FEV1/slow vital capacity ratios, were higher in the COPD+CHF group than in the COPD group, all major "static" volumes-RV, functional residual capacity (FRC), and TLC-were lower in the former group (p < 0.05). There was a greater reduction in FRC than in RV, resulting in the expiratory reserve volume being lower in the COPD+CHF group than in the COPD group. There were relatively proportional reductions in FRC and TLC in the two groups; therefore, IC was also comparable. Consequently, the inspiratory fraction was higher in the COPD+CHF group than in the COPD group (0.42 ± 0.10 vs. 0.36 ± 0.10; p < 0.05). Although the tidal volume/IC ratio was higher in the COPD+CHF group, the relative inspiratory reserve was remarkably similar between the two groups (0.35 ± 0.09 vs. 0.44 ± 0.14; p < 0.05). Conclusions: Despite the restrictive effects of CHF, patients with COPD+CHF have relatively higher inspiratory limits (a greater inspiratory fraction). However, those patients use only a part of those limits, probably in order to avoid critical reductions in inspiratory reserve and increases in elastic recoil. PMID:27832235
Lung volumes during sustained microgravity on Spacelab SLS-1
NASA Technical Reports Server (NTRS)
Elliott, Ann R.; Prisk, G. Kim; Guy, Harold J. B.; West, John B.
1994-01-01
Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (microgravity) on lung volumes has not been reported. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box-and-flowmeter system and a respiratory mass spectrometer. Measurements included functional residual capacity (FRC), expiratory reserve volume (ERV), residual volume (RV), inspiratory and expiratory vital capacities (IVC and EVC), and tidal volume (V9sub T)). Total lung capacity (TLC) was derived from the measured EVC and RV values. With preflight standing values as a comparison, FRC was significantly reduced by 15% (approximately 500 ml) in microgravity and 32% in the supine posture. ERV was reduced by 10 - 20% in microgravity and decreased by 64% in the supine posture. RV was significantly reduced by 18% (310 ml) in microgravity but did not significantly change in the supine posture compared with standing. IVC and EVC were slightly reduced during the first 24 h of microgravity but returned to 1-G standing values within 72 h of microgravity exposure. IVC and EVC in the supine posture were significantly reduced by 12% compared with standing. During microgravity, V(sub T) decreased by 15% (approximately 90 ml), but supine V(sub T) was unchanged compared with preflight standing values. TLC decreased by approximately 8% during microgravity and in the supine posture compared with preflight standing. The reductions in FRC, ERV, and RV during microgravity are probably due to the cranial shift of the diaphragm, an increase in intrathoracic blood volume, and more uniform alveolar expansion.
Sprinting performance on the Woodway Curve 3.0 is related to muscle architecture.
Mangine, Gerald T; Fukuda, David H; Townsend, Jeremy R; Wells, Adam J; Gonzalez, Adam M; Jajtner, Adam R; Bohner, Jonathan D; LaMonica, Michael; Hoffman, Jay R; Fragala, Maren S; Stout, Jeffrey R
2015-01-01
To determine if unilateral measures of muscle architecture in the rectus femoris (RF) and vastus lateralis (VL) were related to (and predictive of) sprinting speed and unilateral (and bilateral) force (FRC) and power (POW) during a 30 s maximal sprint on the Woodway Curve 3.0 non-motorized treadmill. Twenty-eight healthy, physically active men (n = 14) and women (n = 14) (age = 22.9 ± 2.4 years; body mass = 77.1 ± 16.2 kg; height = 171.6 ± 11.2 cm; body-fa t = 19.4 ± 8.1%) completed one familiarization and one 30-s maximal sprint on the TM to obtain maximal sprinting speed, POW and FRC. Muscle thickness (MT), cross-sectional area (CSA) and echo intensity (ECHO) of the RF and VL in the dominant (DOM; determined by unilateral sprinting power) and non-dominant (ND) legs were measured via ultrasound. Pearson correlations indicated several significant (p < 0.05) relationships between sprinting performance [POW (peak, DOM and ND), FRC (peak, DOM, ND) and sprinting time] and muscle architecture. Stepwise regression indicated that POW(DOM) was predictive of ipsilateral RF (MT and CSA) and VL (CSA and ECHO), while POW(ND) was predictive of ipsilateral RF (MT and CSA) and VL (CSA); sprinting power/force asymmetry was not predictive of architecture asymmetry. Sprinting time was best predicted by peak power and peak force, though muscle quality (ECHO) and the bilateral percent difference in VL (CSA) were strong architectural predictors. Muscle architecture is related to (and predictive of) TM sprinting performance, while unilateral POW is predictive of ipsilateral architecture. However, the extent to which architecture and other factors (i.e. neuromuscular control and sprinting technique) affect TM performance remains unknown.
Lung volumes during sustained microgravity on Spacelab SLS-1.
Elliott, A R; Prisk, G K; Guy, H J; West, J B
1994-10-01
Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (mu G) on lung volumes has not been reported. Pulmonary function tests were performed by four subjects before, during, and after 9 days of mu G exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box-and-flowmeter system and a respiratory mass spectrometer. Measurements included functional residual capacity (FRC), expiratory reserve volume (ERV), residual volume (RV), inspiratory and expiratory vital capacities (IVC and EVC), and tidal volume (VT). Total lung capacity (TLC) was derived from the measured EVC and RV values. With preflight standing values as a comparison, FRC was significantly reduced by 15% (approximately 500 ml) in mu G and 32% in the supine posture. ERV was reduced by 10-20% in mu G and decreased by 64% in the supine posture. RV was significantly reduced by 18% (310 ml) in mu G but did not significantly change in the supine posture compared with standing. IVC and EVC were slightly reduced during the first 24 h of mu G but returned to 1-G standing values within 72 h of mu G exposure. IVC and EVC in the supine posture were significantly reduced by 12% compared with standing. During mu G, VT decreased by 15% (approximately 90 ml), but supine VT was unchanged compared with preflight standing values. TLC decreased by approximately 8% during mu G and in the supine posture compared with preflight standing. The reductions in FRC, ERV, and RV during mu G are probably due to the cranial shift of the diaphragm, an increase in intrathoracic blood volume, and more uniform alveolar expansion.
High Fidelity Modeling of Field Reversed Configuration (FRC) Thrusters
2015-10-01
dispersion depends on the Riemann solver • Variables are allowed to be discontinuous at the cell interfaces Advantages - Method is conservative...release; distribution unlimited Discontinuous Galerkin (2) • Riemann problems are solved at each interface to compute fluxes • The source of dissipation
Composite resin reinforcement of flared canals using light-transmitting plastic posts.
Lui, J L
1994-05-01
Composite resins have been advocated as a reinforcing build-up material for badly damaged endodontically treated teeth with flared canals. However, the control of an autocuring composite resin is difficult because it polymerizes rapidly within the root canal. While the light-curing composite resins are more user friendly, their polymerization can be a problem deep in the root canal. Light-transmitting plastic posts allow the transmission of light into the root canal and enable intraradicular composite resin reconstitution and reinforcement of weakened roots. At the same time, the light-transmitting plastic post forms an optimal post canal in the rehabilitated root and can accurately fit a matching retentive final post. These light-transmitting posts are a useful addition to the dental armamentarium.
Studies on Plasmoid Merging using Compact Toroid Injectors
NASA Astrophysics Data System (ADS)
Allfrey, Ian; Matsumoto, Tadafumi; Roche, Thomas; Gota, Hiroshi; Edo, Takahiro; Asai, Tomohiko; Sheftman, Daniel; Osin Team; Dima Team
2017-10-01
C-2 and C-2U experiments have used magnetized coaxial plasma guns (MCPG) to inject compact toroids (CTs) for refueling the long-lived advanced beam-driven field-reversed configuration (FRC) plasma. This refueling method will also be used for the C-2W experiment. To minimize momentum transfer from the CT to the FRC two CTs are injected radially, diametrically opposed and coincident in time. To improve understanding of the CT characteristics TAE has a dedicated test bed for the development of CT injectors (CTI), where plasmoid merging experiments are performed. The test bed has two CTIs on axis with both axial and transverse magnetic fields. The 1 kG magnetic fields, intended to approximate the magnetic field strength and injection angle on C-2W, allow studies of cross-field transport and merging. Both CTIs are capable of injecting multiple CTs at up to 1 kHz. The resulting merged CT lives >100 μs with a radius of 25 cm. More detailed results of CT parameters will be presented.
1969-09-10
The Hyper III was a low-cost test vehicle for an advanced lifting-body shape. Like the earlier M2-F1, it was a "homebuilt" research aircraft, i.e., built at the Flight Research Center (FRC), later redesignated the Dryden Flight Research Center. It had a steel-tube frame covered with Dacron, a fiberglass nose, sheet aluminum fins, and a wing from an HP-11 sailplane. Construction was by volunteers at the FRC. Although the Hyper III was to be flown remotely in its initial tests, it was fitted with a cockpit for a pilot. On the Hyper III's only flight, it was towed aloft attached to a Navy SH-3 helicopter by a 400-foot cable. NASA research pilot Bruce Peterson flew the SH-3. After he released the Hyper III from the cable, NASA research pilot Milt Thompson flew the vehicle by radio control until the final approach when Dick Fischer took over control using a model-airplane radio-control box. The Hyper III flared, then landed and slid to a stop on Rogers Dry Lakebed.
Issues with Strong Compression of Plasma Target by Stabilized Imploding Liner
NASA Astrophysics Data System (ADS)
Turchi, Peter; Frese, Sherry; Frese, Michael
2017-10-01
Strong compression (10:1 in radius) of an FRC by imploding liquid metal liners, stabilized against Rayleigh-Taylor modes, using different scalings for loss based on Bohm vs 100X classical diffusion rates, predict useful compressions with implosion times half the initial energy lifetime. The elongation (length-to-diameter ratio) near peak compression needed to satisfy empirical stability criterion and also retain alpha-particles is about ten. The present paper extends these considerations to issues of the initial FRC, including stability conditions (S*/E) and allowable angular speeds. Furthermore, efficient recovery of the implosion energy and alpha-particle work, in order to reduce the necessary nuclear gain for an economical power reactor, is seen as an important element of the stabilized liner implosion concept for fusion. We describe recent progress in design and construction of the high energy-density prototype of a Stabilized Liner Compressor (SLC) leading to repetitive laboratory experiments to develop the plasma target. Supported by ARPA-E ALPHA Program.
NIMROD simulations of the IPA FRC experiment
NASA Astrophysics Data System (ADS)
Milroy, Richard
2015-11-01
The IPA experiment created a high temperature plasma by merging and compressing supersonic θ-pinch formed FRCs. The NIMROD code has been used to simulate this process. These calculations include the θ-pinch formation and acceleration of two FRC's using the dynamic formation methodology, and their translation to a central compression chamber where they merge and are magnetically compressed. Transport coefficients have been tuned so simulation results agree well with experimental observation. The inclusion of the Hall term is essential for the FRCs merge quickly, as observed experimentally through the excluded flux profiles. The inclusion of a significant anisotropic viscosity is required for the excluded flux profiles to agree well with the experiment. We plan to extend this validation work using the new ARPA-E funded Venti experiment at Helion Energy in Redmond WA. This will be a very well diagnosed experiment where two FRCs merge (like the IPA experiment) and are then compressed to near-fusion conditions. Preliminary calculations with parameters relevant to this experiment have been made, and some numerical issues identified.
Optical diagnostics on the Magnetized Shock Experiment (MSX)
NASA Astrophysics Data System (ADS)
Boguski, J. C.; Weber, T. E.; Intrator, T. P.; Smith, R. J.; Dunn, J. P.; Hutchinson, T. M.; Gao, K. W.
2013-10-01
The Magnetized Shock Experiment (MSX) at Los Alamos National Laboratory was built to investigate the physics of high Alfvén Mach number, supercritical, magnetized shocks through the acceleration and subsequent stagnation of a Field Reversed Configuration (FRC) plasmoid against a magnetic mirror and/or plasma target. A suite of optical diagnostics has recently been fielded on MSX to characterize plasma conditions during the formation, acceleration, and stagnation phases of the experiment. CCD-backed streak and framing cameras, and a fiber-based visible light array, provide information regarding FRC shape, velocity, and instability growth. Time-resolved narrow and broadband spectroscopy provides information on pre-shock plasma temperature, impurity levels, shock location, and non-thermal ion distributions within the shock region. Details of the diagnostic design, configuration, and characterization will be presented along with initial results. This work is supported by the Center for Magnetic Self Organization, DoE OFES and NNSA under LANS contract DE-AC52-06NA25369. Approved for public release: LA-UR- 13-25190.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deng, B. H., E-mail: bdeng@trialphaenergy.com; Beall, M.; Schroeder, J.
2016-11-15
A high sensitivity multi-channel far infrared laser diagnostics with switchable interferometry and polarimetry operation modes for the advanced neutral beam-driven C-2U field-reversed configuration (FRC) plasmas is described. The interferometer achieved superior resolution of 1 × 10{sup 16} m{sup −2} at >1.5 MHz bandwidth, illustrated by measurement of small amplitude high frequency fluctuations. The polarimetry achieved 0.04° instrument resolution and 0.1° actual resolution in the challenging high density gradient environment with >0.5 MHz bandwidth, making it suitable for weak internal magnetic field measurements in the C-2U plasmas, where the maximum Faraday rotation angle is less than 1°. The polarimetry resolution datamore » is analyzed, and high resolution Faraday rotation data in C-2U is presented together with direct evidences of field reversal in FRC magnetic structure obtained for the first time by a non-perturbative method.« less
2014-01-01
Background Chlamydia psittaci (Cp) is a respiratory pathogen capable of inducing acute pulmonary zoonotic disease (psittacosis) or persistent infection. To elucidate the pathogenesis of this infection, a translational large animal model was recently introduced by our group. This study aims at quantifying and differentiating pulmonary dysfunction and acid–base imbalances induced by Cp. Methods Forty-two calves were grouped in (i) animals inoculated with Cp (n = 21) and (ii) controls sham-inoculated with uninfected cell culture (n = 21). For pulmonary function testing, impulse oscillometry, capnography, and FRC (functional residual capacity) measurement were applied to spontaneously breathing animals. Variables of acid–base status were assessed in venous blood using both (i) traditional Henderson-Hasselbalch and (ii) strong ion approach. Results Both obstructive and restrictive pulmonary disorders were induced in calves experimentally inoculated with Cp. Although disorders in respiratory mechanics lasted for 8–11 days, the pattern of spontaneous breathing was mainly altered in the period of acute illness (until 4 days post inoculation, dpi). Expiration was more impaired than inspiration, resulting in elevated FRC. Ventilation was characterised by a reduction in tidal volume (−25%) combined with an increased percentage of dead space volume and a significant reduction of alveolar volume by 10%. Minute ventilation increased significantly (+50%) due to a compensatory doubling of respiratory rate. Hyperventilatory hypocapnia at 2–3 dpi resulted in slightly increased blood pH at 2 dpi. However, the acid–base equilibrium was additionally influenced by metabolic components, i.e. the systemic inflammatory response, all of which were detected with help of the strong ion theory. Decreased concentrations of albumin (2–10 dpi), a negative acute-phase marker, resulted in a decrease in the sum of non-volatile weak acids (Atot), revealing an alkalotic effect. This was counterbalanced by acidic effects of decreased strong ion difference (SID), mediated by the interplay between hypochloraemia (alkalotic effect) and hyponatraemia (acidic effect). Conclusions This bovine model was found to be suitable for studying pathophysiology of respiratory Cp infection and may help elucidating functional host-pathogen interactions in the mammalian lung. PMID:24517577
Evaluation Options for Family Resource Centers.
ERIC Educational Resources Information Center
Horsch, Karen, Ed.; Weiss, Heather B., Ed.
Family resource centers (FRC) are emerging as a promising program approach to solving urgent social problems. Evaluation plays an important role in learning how these programs work, what their impact is, and whether they should be expanded. However, FRCs pose unique challenges to evaluation. This report considers the challenges to evaluating FRCs,…
ERIC Educational Resources Information Center
McIntyre, Nancy
2012-01-01
This article features an after-school FIRST Lego League (FLL) program at Chaminade Middle School in Chatsworth, California, USA. The after-school FLL program feeds into the high school FIRST Robotics Competition (FRC) program wherein aspiring young engineers come to the high school team with several years of FLL experience. Through the FLL…
Coast Guard Cutter Procurement: Background and Issues for Congress
2013-07-24
strategy for the OPC; Coast Guard Cutter Procurement: Background and Issues for Congress Congressional Research Service • the potential for using...Acquisition Strategy ........................................................... 24 2012 Testimony...Guard’s funding requests and acquisition strategies for the NSC, OPC, and FRC programs. Congress’s decisions on these three programs could
Shori, Deepa; Pandey, Swapnil; Kubde, Rajesh; Rathod, Yogesh; Atara, Rahul; Rathi, Shravan
2013-10-01
Fiber posts are widely used for restoration of mutilated teeth that lack adequate coronal tooth structure to retain a core for definitive restoration, bond between the fiber post and composite material depends upon the chemical reaction between the post surface and the resin material used for building up the core. In attempt to maximize the resin bonding with fiber post, different post surface conditioning is advocated. Therefore the purpose of the study is to examine the interfacial strength between fiber post and composite, as core build-up material after different surface treatments of fiber posts. Twenty fiber posts were split into four groups off five each according to different surface treatments viz. Group I-(Negative Control), Group II-Silanization (Positive control), Group III-(37% Phosphoric Acid & Silanization) ,Group IV- (10% Hydrogen Peroxide and Silanization). With the preformed plastic mould, a core of dual cure composite resin around the fiber post having the uniform thickness was created. Tensile bond strength of each specimen was measured under Universal Testing Machine (UTM) at the cross head speed of 3mm/min. The results achieved with 10% Hydrogen peroxide had a marked effect on micro tensile bond strength values between the tested materials. Immense enhancement in the silanization efficiency of quartz fiber phase was observed with different surface chemical treatment of the resin phase of fiber posts with the marked increase in the micro-tensile bond strength between fiber post and composite core. Shori D, Pandey S, Kubde R, Rathod Y, Atara R, Rathi S. To evaluate and compare the effect of different Post Surface treatments on the Tensile Bond Strength between Fiber Posts and Composite Resin. J Int Oral Health 2013; 5(5):27-32.
Accelerated aging of adhesive-mediated fiber post-resin composite bonds: A modeling approach.
Radovic, Ivana; Monticelli, Francesca; Papacchini, Federica; Magni, Elisa; Cury, Alvaro Hafiz; Vulicevic, Zoran R; Ferrari, Marco
2007-08-01
Although fiber posts luted in root canals are not directly exposed to oral fluids, water storage is considered as in vitro accelerated aging test for bonded interfaces. The aim of the study was to evaluate the influence of accelerated water aging on fiber post-resin composite adhesion. Forty fiber posts (DT Light Post, RTD) were randomly divided into two main groups, according to the surface treatment performed. Group I: XPBond adhesive (Dentsply Caulk); Group II: sandblasting (Rocatec-Pre, 3M ESPE) and XPBond. Dual-cured resin cement (Calibra, Dentsply Caulk) and flowable composite (X-Flow, Dentsply Caulk) were applied on the posts to produce cylindrical specimens. The bond strength at the interface between post and cement/composite was measured with the microtensile test according to the non-trimming technique. Half of the sticks were tested immediately for bond strength, while in the other half testing was performed after 1 month of water storage at 37 degrees C. Post-cement/composite interfaces were evaluated under SEM prior and after water aging. Statistical analysis was performed using the Kruskal-Wallis ANOVA followed by Dunn's multiple range test (p<0.05). Immediate bond strength was higher on sandblasted posts. After water aging the two post surface treatments resulted comparable in bond strength. Resin cement achieved higher bond strength to fiber posts than flowable composite. Water aging significantly reduced bond strength. Sandblasting followed by adhesive coating may improve immediate post-resin bond strength in comparison to adhesive alone. However, fiber post-resin bond strength mediated by hydrophilic adhesive tends to decrease after water aging.
FRC Compression Heating Experiment (FRCHX) at AFRL
2007-06-01
Air Force Research Laboratory ( AFRL ) and Los Alamos National Laboratory (LANL) have been... Air Force Research Laboratory , Directed Energy Directorate, 3550 Aberdeen Avenue SE Kirtland AFB, NM 87117-5776 USA 8. PERFORMING ORGANIZATION REPORT...Matt Domonkos, Don Gale, Bernard Martinez, Jerry Parker, Dale Ralph, Ed Ruden, and Wayne Sommars Air Force Research Laboratory , Directed
Dendritic cells control fibroblastic reticular network tension and lymph node expansion.
Acton, Sophie E; Farrugia, Aaron J; Astarita, Jillian L; Mourão-Sá, Diego; Jenkins, Robert P; Nye, Emma; Hooper, Steven; van Blijswijk, Janneke; Rogers, Neil C; Snelgrove, Kathryn J; Rosewell, Ian; Moita, Luis F; Stamp, Gordon; Turley, Shannon J; Sahai, Erik; Reis e Sousa, Caetano
2014-10-23
After immunogenic challenge, infiltrating and dividing lymphocytes markedly increase lymph node cellularity, leading to organ expansion. Here we report that the physical elasticity of lymph nodes is maintained in part by podoplanin (PDPN) signalling in stromal fibroblastic reticular cells (FRCs) and its modulation by CLEC-2 expressed on dendritic cells. We show in mouse cells that PDPN induces actomyosin contractility in FRCs via activation of RhoA/C and downstream Rho-associated protein kinase (ROCK). Engagement by CLEC-2 causes PDPN clustering and rapidly uncouples PDPN from RhoA/C activation, relaxing the actomyosin cytoskeleton and permitting FRC stretching. Notably, administration of CLEC-2 protein to immunized mice augments lymph node expansion. In contrast, lymph node expansion is significantly constrained in mice selectively lacking CLEC-2 expression in dendritic cells. Thus, the same dendritic cells that initiate immunity by presenting antigens to T lymphocytes also initiate remodelling of lymph nodes by delivering CLEC-2 to FRCs. CLEC-2 modulation of PDPN signalling permits FRC network stretching and allows for the rapid lymph node expansion--driven by lymphocyte influx and proliferation--that is the critical hallmark of adaptive immunity.
Dendritic Cells Control Fibroblastic Reticular Network Tension and Lymph Node Expansion
Acton, Sophie E.; Farrugia, Aaron J.; Astarita, Jillian L.; Mourão-Sá, Diego; Jenkins, Robert P.; Nye, Emma; Hooper, Steven; van Blijswijk, Janneke; Rogers, Neil C.; Snelgrove, Kathryn J.; Rosewell, Ian; Moita, Luis F.; Stamp, Gordon; Turley, Shannon J.; Sahai, Erik; Sousa, Caetano Reis e
2014-01-01
Following immunogenic challenge, infiltrating and dividing lymphocytes significantly increase lymph node (LN) cellularity leading to organ expansion1,2. Here we report that the physical elasticity of LNs is maintained in part by podoplanin (PDPN) signalling in stromal fibroblastic reticular cells (FRCs) and its modulation by CLEC-2 expressed on dendritic cells (DCs). We show that PDPN induces actomyosin contractility in FRCs via activation of RhoA/C and downstream Rho-kinase. Engagement by CLEC-2 causes PDPN clustering and rapidly uncouples PDPN from RhoA/C activation, relaxing the actomyosin cytoskeleton and permitting FRC stretching. Notably, administration of CLEC-2 protein to immunised mice augments LN expansion. In contrast, the latter is significantly constrained in mice selectively lacking CLEC-2 expression in DCs. Thus, the same DCs that initiate immunity by presenting antigens to T lymphocytes3 also initiate remodeling of LNs by delivering CLEC-2 to FRCs. CLEC-2 modulation of PDPN signalling permits FRC network stretching and allows for the rapid LN expansion driven by lymphocyte influx and proliferation that is the critical hallmark of adaptive immunity. PMID:25341788
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burgos, W.D.
2009-09-02
This report summarizes research conducted in conjunction with a project entitled “Reaction-Based Reactive Transport Modeling of Iron Reduction and Uranium Immobilization at Area 2 of the NABIR Field Research Center”, which was funded through the Integrative Studies Element of the former NABIR Program (now the Environmental Remediation Sciences Program) within the Office of Biological and Environmental Research. Dr. William Burgos (The Pennsylvania State University) was the overall PI/PD for the project, which included Brian Dempsey (Penn State), Gour-Tsyh (George) Yeh (Central Florida University), and Eric Roden (formerly at The University of Alabama, now at the University of Wisconsin) as separately-fundedmore » co-PIs. The project focused on development of a mechanistic understanding and quantitative models of coupled Fe(III)/U(VI) reduction in FRC Area 2 sediments. The work builds on our previous studies of microbial Fe(III) and U(VI) reduction, and was directly aligned with the Scheibe et al. ORNL FRC Field Project at Area 2.« less
A direct fusion drive for rocket propulsion
NASA Astrophysics Data System (ADS)
Razin, Yosef S.; Pajer, Gary; Breton, Mary; Ham, Eric; Mueller, Joseph; Paluszek, Michael; Glasser, Alan H.; Cohen, Samuel A.
2014-12-01
The Direct Fusion Drive (DFD), a compact, anuetronic fusion engine, will enable more challenging exploration missions in the solar system. The engine proposed here uses a deuterium-helium-3 reaction to produce fusion energy by employing a novel field-reversed configuration (FRC) for magnetic confinement. The FRC has a simple linear solenoid coil geometry yet generates higher plasma pressure, hence higher fusion power density, for a given magnetic field strength than other magnetic-confinement plasma devices. Waste heat generated from the plasma's Bremsstrahlung and synchrotron radiation is recycled to maintain the fusion temperature. The charged reaction products, augmented by additional propellant, are exhausted through a magnetic nozzle. A 1 MW DFD is presented in the context of a mission to deploy the James Webb Space Telescope (6200 kg) from GPS orbit to a Sun-Earth L2 halo orbit in 37 days using just 353 kg of propellant and about half a kilogram of 3He. The engine is designed to produce 40 N of thrust with an exhaust velocity of 56.5 km/s and has a specific power of 0.18 kW/kg.
First results of transcritical magnetized collisionless shock studies on MSX
NASA Astrophysics Data System (ADS)
Weber, T. E.; Smith, R. J.; Hutchinson, T. M.; Taylor, S. F.; Hsu, S. C.
2014-10-01
Magnetized collisionless shocks exhibit transitional length and time scales much shorter than can be created through collisional processes. They are common throughout the cosmos, but have historically proven difficult to create in the laboratory. The Magnetized Shock Experiment (MSX) at LANL produces super-Alfvénic shocks through the acceleration and subsequent stagnation of Field Reversed Configuration (FRC) plasmoids against a strong magnetic mirror and flux-conserving vacuum boundary. Plasma flows have been produced with sonic and Alfvén Mach numbers up to ~10 over a wide range of plasma beta with embedded perpendicular, oblique, and parallel magnetic field. Macroscopic ion skin-depth and long ion-gyroperiod enable diagnostic access to relevant shock physics using common methods. Variable plasmoid velocity, density, temperature, and magnetic field provide access to a wide range of shock conditions, and a campaign to study the physics of transcritical and supercritical shocks within the FRC plasmoid is currently underway. An overview of the experimental design, diagnostics suite, physics objectives, and recent results will be presented. Supported by DOE Office of Fusion Energy Sciences under DOE Contract DE-AC52-06NA25369.
Hybrid reconstruction of field-reversed configurations
NASA Astrophysics Data System (ADS)
Steinhauer, Loren; TAE Team
2016-10-01
Field-reversed configurations (FRC) are poorly represented by fluid-based models and require instead an ion-distribution function. Two such populations are needed since ``core'' ions are roughly restricted to the region inside the separatrix, whereas ``periphery'' ions can escape along open field lines. The Vlasov equation governs the distribution, the general solution to which is an arbitrary function of the constants of motion (Hamiltonian, canonical angular momentum). Only a small subset of such distributions are realistic in view of collisions, which smooth the distribution, and instabilities, which reorganize the field structure. Collisions and end loss are included if the distribution is a solution to the Fokker-Planck (FP) equation. Vlasov and FP solutions are nearly identical in weakly-collisional plasmas. Numerical construction of such equilibria requires solving both Ampere's law for the magnetic flux variable and the ponderous task of a full velocity-space integration at each point. The latter can be done analytically by expressing the distribution as the superposition of simple basis elements. This procedure allows rapid reconstruction of evolving equilibria based on limited diagnostic observables in FRC experiments.
Infant lung function tests as endpoints in the ISIS multicenter clinical trial in cystic fibrosis.
Davis, Stephanie D; Ratjen, Felix; Brumback, Lyndia C; Johnson, Robin C; Filbrun, Amy G; Kerby, Gwendolyn S; Panitch, Howard B; Donaldson, Scott H; Rosenfeld, Margaret
2016-05-01
The Infant Study of Inhaled Saline (ISIS) in CF was the first multicenter clinical trial to utilize infant pulmonary function tests (iPFTs) as an endpoint. Secondary analysis of ISIS data was conducted in order to assess feasibility of iPFT measures and their associations with respiratory symptoms. Standard deviations were calculated to aid in power calculations for future clinical trials. Seventy-three participants enrolled, 70 returned for the final visit; 62 (89%) and 45 (64%) had acceptable paired functional residual capacity (FRC) and raised volume measurements, respectively. Mean baseline FEV0.5, FEF75 and FRC z-scores were 0.3 (SD: 1.2), -0.2 (SD: 2.0), and 1.8 (SD: 2.0). iPFTs are not appropriate primary endpoints for multicenter clinical trials due to challenges of obtaining acceptable data and near-normal average raised volume measurements. Raised volume measures have potential to serve as secondary endpoints in future clinical CF trials. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Pre- and Post-Processing Tools to Create and Characterize Particle-Based Composite Model Structures
2017-11-01
ARL-TR-8213 ● NOV 2017 US Army Research Laboratory Pre- and Post -Processing Tools to Create and Characterize Particle-Based...ARL-TR-8213 ● NOV 2017 US Army Research Laboratory Pre- and Post -Processing Tools to Create and Characterize Particle-Based Composite...AND SUBTITLE Pre- and Post -Processing Tools to Create and Characterize Particle-Based Composite Model Structures 5a. CONTRACT NUMBER 5b. GRANT
Overweight, Obesity, and Lung Function in Children and Adults-A Meta-analysis.
Forno, Erick; Han, Yueh-Ying; Mullen, James; Celedón, Juan C
There is conflicting evidence on the effect of obesity on lung function in adults and children with and without asthma. We aimed to evaluate the relation between overweight or obesity and lung function, and whether such relationship varies by age, sex, or asthma status. We searched PubMed, Scopus, CINAHL, Cochrane, and EMBASE for all studies (in English) reporting on obesity status (by body mass index) and lung function, from 2005 to 2017. Main outcomes were forced expiratory volume in 1 second (FEV 1 ), forced vital capacity (FVC), FEV 1 /FVC, forced expiratory flow between 25th and 75th percentile of the forced vital capacity (FEF 25-75 ), total lung capacity (TLC), residual volume (RV), and functional residual capacity (FRC). Random-effects models were used to calculate the pooled risk estimates; each study was weighed by the inverse effect size variance. For each outcome, we compared overweight or obese ("obese") subjects with those of normal weight. All measures of lung function were decreased among obese subjects. Obese adults showed a pattern (lower FEV 1 , FVC, TLC, and RV) different from obese children (more pronounced FEV 1 /FVC deficit with unchanged FEV 1 or FVC). There were also seemingly different patterns by asthma status, in that subjects without asthma had more marked decreases in FEV 1 , TLC, RV, and FRC than subjects with asthma. Subjects who were obese (as compared with overweight) had even further decreased FEV 1 , FVC, TLC, RV, and FRC. Obesity is detrimental to lung function, but specific patterns differ between children and adults. Physicians should be aware of adverse effects of obesity on lung function, and weight control should be considered in the management of airway disease among the obese. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
1967-01-11
In this 1967 NASA Flight Reserch Center photograph the Lunar Landing Research Vehicle (LLRV) is viewed from the front. This photograph provideds a good view of the pilot’s platform with the restrictive cockpit view like that of he real Lunar Module (LM) When Apollo planning was underway in 1960, NASA was looking for a simulator to profile the descent to the Moon's surface. Three concepts surfaced: an electronic simulator, a tethered device, and the ambitious Dryden contribution, a free-flying vehicle. All three became serious projects, but eventually the NASA Flight Research Center’s (FRC) Lunar Landing Research Vehicle (LLRV) became the most significant one. After conceptual planning and meetings with engineers from Bell Aerosystems Company, Buffalo, N.Y., NASA FRC issued a $3.6 million production contract awarded in 1963, for delivery of the first of two vehicles for flight studies. Built of tubular aluminum alloy like a giant four-legged bedstead, the vehicle was to simulate a lunar landing profile from around 1500 feet to the Moon’s surface. The LLRV had a turbofan engine mounted vertically in a gimbal, with 4200 pounds of thrust. The engine, lifted the vehicle up to the test altitude and was then throttled back to support five-sixths of the vehicle's weight, thus simulating the reduced gravity of the Moon. Two lift rockets with thrust that could be varied from 100 to 500 pounds handled the LLRV's rate of descent and horizontal translations. Sixteen smaller rockets, mounted in pairs, gave the pilot control in pitch, yaw, and roll.. The pilot’s platform extended forward between two legs while an electronics platform, similarly located, extended rearward. The pilot had a zero-zero ejection seat that would then lift him away to safety. The two LLRVs were shipped from Bell to the FRC in April 1964, with program emphasis on vehicle No. 1. The first flight, Oct. 30, 1964, NASA research pilot Joe Walker flew it three times for a total of just under 60 seconds
Saber, Moosa
2011-08-01
One focus of integrated pest management (IPM) is the use of biological and chemical control in an optimal way. The availability of selective pesticides is important as is information about both lethal and sublethal effects of pesticides on biocontrol agents. Acute and sublethal effects of imidacloprid and fenpyroximate exposure were studied on adult stage of egg parasitoid Trichogramma cacoeciae Marchal and the emergence rate and life table parameters were determined. The adult wasps were exposed to field recommended concentration (FRC) of the pesticides on glass plates. Field rates of imidacloprid and fenpyroximate caused 100 and 32% adult mortality, respectively. Based on concentration-response experiments, the LC(50) values of imidacloprid and fenpyroximate were 6.25 and 1,949 ppm, respectively. The effect of imidacloprid and fenpyroximate on larvae, prepupae and pupae of the parasitoid was tested by exposing parasitized eggs of Sitotroga cerealella Olivier or Cydia pomonella L. to the FRC. Imidacloprid and fenpyroximate reduced adult emergence by 10.7 and 29%, respectively, when S. cerealella eggs were used as the host and 10.9 and 24.9%, respectively, when C. pomonella eggs were used as the host. Population parameters of emerged adults from treated pre-imaginal stages by FRC of the pesticides were also studied. The parameters were longevity and progeny production of emergent adults and also intrinsic rate of increase (r ( m )), generation time (T) and doubling time (DT). Longevity and progeny production of the emergent adults was not affected by pesticide exposure in comparison to the control. In addition, none of population parameters such as r ( m ), T and DT were affected by pesticide exposure. The intrinsic rate of increase for the control, fenpyroximate and imidacloprid exposed populations were 0.388, 0.374, and 0.372 female offspring per female per day, respectively. Overall, results of this study suggest a relative compatibility between fenpyroximate and T. cacoeciae, but imidacloprid showed deleterious effects on adults of the parasitoid.
M2-F2 flight preparation and launch
NASA Technical Reports Server (NTRS)
1969-01-01
This movie clip runs about 27 seconds and shows the cockpit canopy close-out by the ground crew, the aircraft hanging from the NB-52B wing pylon, and the M2-F2 being dropped away from the mothership. A fleet of lifting bodies flown at the NASA Flight Research Center (FRC), Edwards, California, from 1963 to l975 demonstrated the ability of pilots to maneuver (in the atmosphere) and safely land a wingless vehicle. These lifting bodies were basically designed so they could fly back to Earth from space and be landed like an aircraft at a pre-determined site. They served as precursors of today's Space Shuttle, the X-33, and the X-38, providing technical and operational engineering data that shaped all three space vehicles. (In 1976 NASA renamed the FRC as the NASA Dryden Flight Research Center (DFRC) in honor of Hugh L. Dryden.) In 1962, FRC Director Paul Bikle approved a program to build a lightweight, unpowered lifting body as a prototype to flight test the wingless concept. It would look like a 'flying bathtub,' and was designated the M2-F1. Built by Gus Briegleb, a sailplane builder from El Mirage, California, it featured a plywood shell, placed over a tubular steel frame crafted at the FRC. Construction was completed in 1963. The success of Dryden's M2-F1 program led to NASA's development and construction of two heavyweight lifting bodies based on studies at NASA Ames Research Center and NASA and Langley Research Center -- the M2-F2 and the HL-10, both built by the Northrop Corporation, Los Angeles, California. The 'M' refers to 'manned' and 'F' refers to 'flight' version. 'HL' comes from 'horizontal landing' and '10' is for the tenth lifting body model to be investigated by Langley. The first flight of the M2-F2 -- which looked much like the M2-F1 -- occurred on July 12, 1966. Thompson was the pilot. By then, the same B-52 used to air launch the famed X-15 rocket research aircraft had been modified to also carry the lifting bodies into the air and Thompson was dropped from the B-52 wing pylon mount at an altitude of 45,000 feet on that maiden glide flight. On May 10, 1967, during the sixteenth glide flight leading up to powered flight, a landing accident severely damaged the vehicle and seriously injured the NASA pilot, Bruce Peterson. Following the mishap, the M2-F2 was redesigned with a center fin as the M2-F3, which flew from 1970 to 1972. The M2-F2 weighed 4,620 pounds without ballast, was roughly 22 feet long, and had a width of about 10 feet.
Training in Family Support: Towards a Conceptual Framework. A Report from a Wingspread Conference.
ERIC Educational Resources Information Center
Vogel, Christine
This report presents the results of a conference held by the Family Resource Coalition (FRC) in October 1991, which brought together an interdisciplinary group of academics and family resource practitioners to address questions of quality in family support and, more specifically, in staff development and personnel. The report provides the…
Modeling of neutral entrainment in an FRC thruster
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brackbill, Jeremiah; Gimelshein, Natalia; Gimelshein, Sergey
2012-11-27
Neutral entrainment in a field reversed configuration thruster is modeled numerically with an implicit PIC code extended to include thermal and chemical interactions between plasma and neutral particles. The contribution of charge exchange and electron impact ionization reactions is analyzed, and the sensitivity of the entrainment efficiency to the plasmoid translation velocity and neutral density is evaluated.
The use of reinforced composite resin cement as compensation for reduced post length.
Nissan, J; Dmitry, Y; Assif, D
2001-09-01
Cements that yield high retentive values are believed to allow use of shorter posts. This study investigated the use of reinforced composite resin cement as compensation for reduced dowel length. The retention values of stainless steel posts (parallel-sided ParaPost and tapered Dentatus in 5-, 8-, and 10-mm lengths) luted with Flexi-Flow titanium-reinforced composite resin and zinc phosphate cements were evaluated. Single-rooted extracted human teeth with crowns (n = 120), removed at the cementoenamel junction, were randomly divided into 4 groups of 30 samples each. Different post lengths were luted with either Flexi-Flow or zinc phosphate. Each sample was placed into a specialized jig and on a tensile testing machine with a crosshead speed of 2 mm/min, applied until failure. The effect of different posts and cements on the force required to dislodge the dowels was evaluated with multiple analyses of variance (ANOVA). One-way ANOVA with Scheffé contrast was applied to determine the effect of different post lengths on the retentive failure of posts luted with the 2 agents. Flexi-Flow reinforced composite resin cement significantly increased retention of ParaPost and Dentatus dowels (P<.001) compared with zinc phosphate. One-way ANOVA revealed no statistically significant difference (P>.05) between mean retention of both dowels luted with Flexi-Flow for all posts length used (5 mm = 8 mm = 10 mm). Mean retention values of the groups luted with zinc phosphate showed a statistically significant difference (P<.001) for the different post lengths (10 > 8 > 5 mm). Parallel-sided ParaPost dowels demonstrated a higher mean retention than tapered Dentatus dowels (P<.001). In this study, Flexi-Flow reinforced composite resin cement compensated for the reduced length of shorter parallel-sided ParaPost and tapered Dentatus dowels.
NASA Astrophysics Data System (ADS)
Chella Gifta, C.; Prabavathy, S.
2018-05-01
This work presents the energy absorption capacity of hybrid fiber reinforced concrete made with hooked end steel fibers (0.5 and 0.75%) and straight polyester fibers (0.5, 0.8, 1.0 and 2.0%). Compressive toughness (energy absorption capacity) under uni-axial compression was evaluated on 100 × 200 mm size cylindrical specimens with varying steel and polyester fiber content. Efficiency of the hybrid fiber reinforcement is studied with respect to fiber type, size and volume fractions in this investigation. The vertical displacement under uni-axial compression was measured under the applied loads and the load-deformation curves were plotted. From these curves the toughness values were calculated and the results were compared with steel and polyester as individual fibers. The hybridization of 0.5% steel + 0.5% polyester performed well in post peak region due to the addition of polyester fibers with steel fibers and the energy absorption value was 23% greater than 0.5% steel FRC. Peak stress values were also higher in hybrid series than single fiber and based on the results it is concluded that hybrid fiber reinforcement improves the toughness characteristics of concrete without affecting workability.
NASA Astrophysics Data System (ADS)
Kim, Kwan-Woo; Han, Woong; Kim, Byoung-Suhk; Kim, Byung-Joo; An, Kay-Hyeok
2017-09-01
In order to develop the high quality electromagnetic interference shielding efficiency (EMI-SE) materials, Ni-plated carbon fiber fabrics (Ni-CFFs) were prepared by an electroless method. Effects of post heat-treatment conditions on EMI-SE and electrical conductivity of Ni-CFFs/epoxy composites were also investigated. The morphologies and structural properties of Ni-CFFs were measured by a SEM and a XRD. It was found that all the Ni peaks increased with increasing post-heat treatment temperature, indicating that some impurities were removed and nickel particle sharp crystalline peaks. Also, It was found that the EMI-SE of composites enhanced was increased after post heat-treatment. In the frequency range of electromagnetic wave occurred from appliances (3.0 × 107-6.0 × 108), EMI-SE of post-heat treatment Ni-CFs was increased. This result concludes that the EMI-SE of the composites can be enhanced according to the microstructure of Ni in the Ni-CFFs/epoxy composites.
Effect of post cure time and temperature on the properties of two phenolic-fiber composites
NASA Technical Reports Server (NTRS)
Lucy, M. H.; Price, H. L.
1975-01-01
Some effects of post-cure time and temperature on the physicomechanical properties of a phenolic-asbestos and a phenolic-glass composite are studied. The molding and post-curing procedures are discussed along with physical and mechanical test results. It is found that the specific gravity of the panels tested decreased slightly but the hardness always increased with post cure, and that the mechanical properties had different patterns of response to increasing post-cure time and temperature. For tensile properties, strength decreased, modulus increased, and elongation at break exhibited little change. In general, the phenolic-asbestos showed more positive response to post cure than did the phenolic-glass. Mold venting is found to impart better properties to the composites concerned.
Sizing Determination Final Report
1988-02-01
A Name: ERIC WHEATLEY Subject No.: 4 S/N: ------------ Sex.: M Race: BLACK Age...z:ni:zum Frcx-tal Arc - Tahc and -Marker Tool 19.= 6- - B-prozy.ncmatic_ ,’entlon Ar- - T"p_ and Marler Tool ......... .. 26.:; i7 Bitragion Mini-o-u- Frc...tape and Marler Tool ............. 24.5 7 . ilt’-aoion inigmu F-ontal Ar-c - -:•c= Oil- ---................... . ?.. S:-.-_,_ . ................. 1
High Fidelity Modeling of Field Reversed Configuration (FRC) Thrusters
2017-04-22
signatures which can be used for direct, non -invasive, comparison with experimental diagnostics can be produced. This research will be directly... experimental campaign is critical to developing general design philosophies for low-power plasmoid formation, the complexity of non -linear plasma processes...advanced space propulsion. The work consists of numerical method development, physical model development, and systematic studies of the non -linear
Simulations of Axisymmetric Erosion in IFR-Transported Beams
1989-02-21
be significant only when the pi:,h fr)c, an( indi(t:ve F 7 :pile at th head of the beam are weak, as in * . , ’ c. cf Ini. cirari ft. ’ leri roiir...Baker (AFWL/NTYP) Dr. Muhammad Owais (RAAE) D. Dietz (AFWL/NTYP) Lt Col J. Head Department of Energy R. W. Lemke Washington, DC 20545 Attn: Dr. Wilmot
Charge separation and transport of the n=2 instability in C-2 FRC plasmas
NASA Astrophysics Data System (ADS)
Deng, Bihe; Sun, Xuan; Tuszewski, Michel
2012-10-01
Charge separation is critical in the positive feedback loop for gravitational type instabilities to grow [1], such as in the case of the n=2 mode in the C-2 field reversed configuration (FRC) experiment [2]. A fast time response Langmuir probe with minimum perturbation to the plasma is inserted into the edge of the C-2 plasma to measure the plasma floating potential. With the combined plasma wobble motion and spin motion, 2-D scans of the plasma floating potential are obtained, and evidence of charge separation associated with the n=2 instability is observed. The transport due to charge separation is estimated. Charge neutralization can provide an alternative method to stabilize the n=2 mode. An experiment is proposed to test this method with two probes inserted into the plasma from two azimuthally separated ports and an external shorting circuit, to constantly neutralize the charge separation, thus suppress the growth of the n=2 mode. [4pt] [1] R.J. Goldston and P.H. Rutherford, Introduction to Plasma Physics (Institute of Physics Publishing, Bristol, 2000).[0pt] [2]. M.W. Binderbauer et al, Phys. Rev. Lett. 105, 045003 (2010).
Compact toroid injection into C-2U
NASA Astrophysics Data System (ADS)
Roche, Thomas; Gota, H.; Garate, E.; Asai, T.; Matsumoto, T.; Sekiguchi, J.; Putvinski, S.; Allfrey, I.; Beall, M.; Cordero, M.; Granstedt, E.; Kinley, J.; Morehouse, M.; Sheftman, D.; Valentine, T.; Waggoner, W.; the TAE Team
2015-11-01
Sustainment of an advanced neutral beam-driven FRC for a period in excess of 5 ms is the primary goal of the C-2U machine at Tri Alpha Energy. In addition, a criteria for long-term global sustainment of any magnetically confined fusion reactor is particle refueling. To this end, a magnetized coaxial plasma-gun has been developed. Compact toroids (CT) are to be injected perpendicular to the axial magnetic field of C-2U. To simulate this environment, an experimental test-stand has been constructed. A transverse magnetic field of B ~ 1 kG is established (comparable to the C-2U axial field) and CTs are fired across it. As a minimal requirement, the CT must have energy density greater than that of the magnetic field it is to penetrate, i.e., 1/2 ρv2 >=B2 / 2μ0 . This criteria is easily met and indeed the CTs traverse the test-stand field. A preliminary experiment on C-2U shows the CT also capable of penetrating into FRC plasmas and refueling is observed resulting in a 20 - 30% increase in total particle number per single-pulsed CT injection. Results from test-stand and C-2U experiments will be presented.
Rotational stability of a long field-reversed configuration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, D. C., E-mail: coronadocon@msn.com; Steinhauer, L. C.
2014-02-15
Rotationally driven modes of long systems with dominantly axial magnetic field are considered. We apply the incompressible model and order axial wavenumber small. A recently developed gyro-viscous model is incorporated. A one-dimensional equilibrium is assumed, but radial profiles are arbitrary. The dominant toroidal (azimuthal) mode numbers ℓ=1 and ℓ=2 modes are examined for a variety of non-reversed (B) and reversed profiles. Previous results for both systems with rigid rotor equilibria are reproduced. New results are obtained by incorporation of finite axial wavenumber and by relaxing the assumption of rigid electron and ion rotation. It is shown that the frequently troublesomemore » ℓ=2 field reversed configuration (FRC) mode is not strongly affected by ion kinetic effects (in contrast to non-reversed cases) and is likely stabilized experimentally only by finite length effects. It is also shown that the ℓ=1 wobble mode has a complicated behavior and is affected by a variety of configuration and profile effects. The rotationally driven ℓ=1 wobble is completely stabilized by strong rotational shear, which is anticipated to be active in high performance FRC experiments. Thus, observed wobble modes in these systems are likely not driven by rotation alone.« less
Cross-separatrix Coupling in Nonlinear Global Electrostatic Turbulent Transport in C-2U
NASA Astrophysics Data System (ADS)
Lau, Calvin; Fulton, Daniel; Bao, Jian; Lin, Zhihong; Binderbauer, Michl; Tajima, Toshiki; Schmitz, Lothar; TAE Team
2017-10-01
In recent years, the progress of the C-2/C-2U advanced beam-driven field-reversed configuration (FRC) experiments at Tri Alpha Energy, Inc. has pushed FRCs to transport limited regimes. Understanding particle and energy transport is a vital step towards an FRC reactor, and two particle-in-cell microturbulence codes, the Gyrokinetic Toroidal Code (GTC) and A New Code (ANC), are being developed and applied toward this goal. Previous local electrostatic GTC simulations find the core to be robustly stable with drift-wave instability only in the scrape-off layer (SOL) region. However, experimental measurements showed fluctuations in both regions; one possibility is that fluctuations in the core originate from the SOL, suggesting the need for non-local simulations with cross-separatrix coupling. Current global ANC simulations with gyrokinetic ions and adiabatic electrons find that non-local effects (1) modify linear growth-rates and frequencies of instabilities and (2) allow instability to move from the unstable SOL to the linearly stable core. Nonlinear spreading is also seen prior to mode saturation. We also report on the progress of the first turbulence simulations in the SOL. This work is supported by the Norman Rostoker Fellowship.
Phenomenology of beam driven modes in the field reversed configuration
NASA Astrophysics Data System (ADS)
Magee, Richard; Bolte, Nathan; Clary, Ryan; Necas, Ales; Korepanov, Sergey; Smirnov, Artem; Thompson, Matthew; Tajima, Toshiki; THE TAE Team
2016-10-01
The C-2U experiment offers a unique plasma environment combining a high beta field reversed configuration (FRC) embedded in a low beta magnetic mirror with high power neutral beam injection. The beams are injected tangentially into a modest magnetic field so that the orbits of the resulting fast ions encircle the entire plasma. These large orbit particles sustain and stabilize the plasma and suppress turbulence. Measurements of magnetic fluctuations at the edge of the plasma reveal the presence of three coherent beam driven modes: a low frequency, chirping mode, a mode near the ion cyclotron frequency, and a high frequency compressional Alfven mode. Remarkably, none of these modes are observed to have a deleterious effect on global plasma confinement. In fact, the cyclotron mode has the beneficial effect of dramatically enhancing the DD fusion reaction rate by drawing a trail from the plasma ion energy distribution on a sub-collisional timescale. In this presentation, we experimentally characterize the beam driven modes in the C-2U FRC with data from multiple diagnostics including magnetics, spectroscopy, neutral particle analyzers and fusion product diagnostics. Results are compared to a particle-in-cell simulation in a simplified geometry.
Comprehensive approach to fast ion measurements in the beam-driven FRC
NASA Astrophysics Data System (ADS)
Magee, Richard; Smirnov, Artem; Onofri, Marco; Dettrick, Sean; Korepanov, Sergey; Knapp, Kurt; the TAE Team
2015-11-01
The C-2U experiment combines tangential neutral beam injection, edge biasing, and advanced recycling control to explore the sustainment of field-reversed configuration (FRC) plasmas. To study fast ion confinement in such advanced, beam-driven FRCs, a synergetic technique was developed that relies on the measurements of the DD fusion reaction products and the hybrid code Q2D, which treats the plasma as a fluid and the fast ions kinetically. Data from calibrated neutron and proton detectors are used in a complementary fashion to constrain the simulations: neutron detectors measure the volume integrated fusion rate to constrain the total number of fast ions, while proton detectors with multiple lines of sight through the plasma constrain the axial profile of fast ions. One application of this technique is the diagnosis of fast ion energy transfer and pitch angle scattering. A parametric numerical study was conducted, in which additional ad hoc loss and scattering terms of varying strengths were introduced in the code and constrained with measurement. Initial results indicate that the energy transfer is predominantly classical, while, in some cases, non-classical pitch angle scattering can be observed.
Miniaturization of a Combination Langmuir/Mach Probe
NASA Astrophysics Data System (ADS)
Melnik, P. A.; Dehart, T.; Lotz, D.
2009-11-01
A combination Langmuir/Mach probe has been developed to measure electron temperature and density as well as ion flow speed in TCSU. The probe is fully translatable allowing it to diagnose all radial locations of the FRC at either the mid-plane, end section, or in the exhaust jets. The 1/4'' probe stalk consists of interlocking boron nitride cylinders which encompass a 1/8'' diameter stainless steel tube that houses the probe wires. In addition to the stainless steel jacket the probe wires are twisted to minimize electromagnetic noise pickup. The tip of this combo probe is composed of a boron nitride housing and eight .020'' diameter tungsten collection leads. In TCSU, the RMF used to form and sustain the FRC makes Langmuir probe measurements difficult. To this end we have developed a drive circuit that will generate the bias voltages necessary for Langmuir probe operation. This bipolar power supply can produce steady voltages up to 200 volts at loads over 1 amp and can be swept at any frequency up to 1.5 MHz. The probe current and bias voltage will be recorded with an amplifier and transmitted via fiber optic to a receiver allowing the signals to be digitized.
Diagnostic Progress and Results on the Magnetized Shock Experiment
NASA Astrophysics Data System (ADS)
Smith, R. J.; Weber, T. E.
2015-11-01
The Magnetized Shock Experiment (MSX) at LANL is reliably producing Field Reversed Configuration (FRC) plasmas spanning peak densities of ~ 1021-23 m-3, combined Te +Ti of 10s-500eV and velocities of 100-300km/s as a means to producing a laboratory supercritical collision-less shock. Visible light images showing discontinuities indicative of shocks and jetting have been obtained on various targets: co-solenoid B field, a metal wall and counter-solenoidal B fields (FRC capture and reconnection). Two chord interferometry, external and internal magnetic probing are routinely employed and x-ray diagnostic capability has recently been added. The pulsed polarimetry technique is being deployed which can measure the local magnetic field using Lidar Thomson scattering. In addition, a fiber optic version of pulsed polarimetry using a new specialty fiber that enhances fiber backscatter with Fiber Bragg Gratings is being developed. Magnetic fields of order ~ 1T have been measured, however a new modified shock chamber geometry and recent machine modifications enabling operation at increased θ-coil voltage are expected to improve translation speed and hence stagnation pressures. Progress on these diagnostics and results will be presented. DOE support Grant No DE-SC00010559.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milroy, R. D.; Kim, C. C.; Sovinec, C. R.
Three-dimensional simulations of field reversed configuration (FRC) formation and sustainment with rotating magnetic field (RMF) current drive have been performed with the NIMROD code [C. R. Sovinec et al., J. Comput. Phys. 195, 355 (2004)]. The Hall term is a zeroth order effect with strong coupling between Fourier components, and recent enhancements to the NIMROD preconditioner allow much larger time steps than was previously possible. Boundary conditions to capture the effects of a finite length RMF antenna have been added, and simulations of FRC formation from a uniform background plasma have been performed with parameters relevant to the translation, confinement,more » and sustainment-upgrade experiment at the University of Washington [H. Y. Guo, A. L. Hoffman, and R. D. Milroy, Phys. Plasmas 14, 112502 (2007)]. The effects of both even-parity and odd-parity antennas have been investigated, and there is no evidence of a disruptive instability for either antenna type. It has been found that RMF effects extend considerably beyond the ends of the antenna, and that a large n=0 B{sub t}heta can develop in the open-field line region, producing a back torque opposing the RMF.« less
Masking of temperature-induced color changes in a thermo-sensitive fiber post.
Vichi, Alessandro; Schiavetti, Remo; Pacifici, Edoardo; Giovannetti, Agostino; Goracci, Cecilia; Ferrari, Marco
2012-04-01
To evaluate (1) the efficacy of the color changing technology featured by DT Light Illusion Post aimed at safely identifying the post in case of re-treatment, and (2) the efficacy of a resin composite layer to mask the post if color shift occurs due to cold food and beverages. Five "master disks" of 3 mm of thickness were prepared by embedding in a resin composite four thermo-sensitive posts and one translucent post (control) cut in bars. Disks of resin composite in 0.5/1.0/1.5 mm thickness were prepared as well. Digital images were taken of the master disks with and without the overlying of the resin composite disks, at 5 degrees C and at 35 degrees C temperature. By the use of Adobe Photoshop "layering function" and "multi-layer option", differences in color were calculated between the post-free and the post-containing areas. The differences between the resin color and post color were remarkably higher when the temperature was 5 degrees C, showing that the technology of color change of the post was effective. With resin disk overlaid, at 35 degrees C none of the differences in color were above the threshold for clinical acceptability. At 5 degrees C blue and black colored posts were visible when the overlaid resin thickness was 0.5 mm, while at 1.0 mm and 1.5 mm none of the posts were visible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
David R. Veblen; Chen Zhu; Lee Krumholz
The effectiveness and feasibility of bioremediation at the field scale cannot be fully assessed until the mechanisms of immobilization and U speciation in the solid matrix are resolved. However, characterization of the immobilized U and its valence states is extremely difficult, because microbially mediated mineral precipitates are generally nanometer (nm)-sized, poorly crystalline, or amorphous. We are developing combined field emission gun--scanning electron microscopy (FEG-SEM, at Indiana University) and FEG transmission electron microscopy (TEM, at Hopkins) to detect and isolate uranium containing phases; (1) method developments for TEM sample preparations and parallel electron energy loss spectroscopy (EELS) determination of uranium valence;more » and (2) to determine the speciation, fate, reactivity, valence states of immobilized uranium, using the state-of-the-art 300-kV, FEG-TEM. We have obtained preliminary results on contaminated sediments from Area 3 at the Oak Ridge Field Research Center (FRC). TEM results show that the sediments contain numerous minerals, including quartz, mica/clay (muscovite and/or illite), rutile, ilmenite, zircon, and an Al-Sr-Ce-Ca phosphate mineral, none of which contain uranium above the EDS detection limit. Substantial U (up to {approx}2 wt.%) is, however, clearly associated with two materials: (1) the Fe oxyhydroxide and (2) clots of a chemically complex material that is likely a mixture of several nm-scale phases. The Fe oxyhydroxide was identified as goethite from its polycrystalline SAED pattern and EDS analysis showing it to be very Fe-rich; the aggregate also displays one of several morphologies that are common for goethite. U is strongly sorbed to goethite in the FRC sediment, and the ubiquitous association with phosphorous suggests that complexes containing both U and P may play an important role in that sorption. Results from bulk analysis and SEM had previously demonstrated the association of U with Fe and thus suggested that U may be sorbed by Fe oxide or oxyhydroxide (Dr. Roh, image presented by David Watson). However, rigorous identification of the host minerals for U requires TEM results such as these involving imaging, electron diffraction, and spectroscopic analysis. An even higher concentration of U occurs in the chemically complex material noted above. These ''clots'' are high in Fe but also contain C, O, Mg, Al, Si, P, S, Cl, K, Ca, Mn, and U. This chemical complexity strongly suggests that they consist of aggregates of carbonate, silicate, phosphate, and sulfate phases, and TEM images also suggest that they may be intergrowths of numerous exceedingly small nanoparticles. EELS and EFTEM studies should be able to resolve these various components and identify precisely where the uranium is in these complex materials. From the results, it is clear that the FEG-SEM and FEG-TEM can readily detect uranium in the FRC samples. The FEG-SEM allows a wide field of view of the samples and can detect U-rich aggregates as small as 20-30 nm. The FEG-TEM can then focus on these aggregates and use SAED, EDS, EFTEM, and PEELS techniques to determine the valence states, structures, and compositional data for these aggregates. This research will provide a crucial component for a complete understanding of the efficacy of uranium bioremediation.« less
Magnetized Target Fusion - Field Reversed Configuration Formation and Injection (MTF-FRC)
2009-11-06
from accidental breakage and personnel from injury in that event. The pumps for the vacuum system included a Varian dry scroll pump that was...a dry scroll (oil-free) mechanical pump could be used, as mTorr pressures would be sufficient for the vacuum switch voltage hold-off and operation...56 FIGURE 46. ROUGHING PUMP AND VACUUM -GAUGE CONTROLLERS BENEATH THETA COIL CABLE HEADER
High Fidelity Modeling of Field-Reversed Configuration (FRC) Thrusters (Briefing Charts)
2017-05-24
Converged Math → Irrelevant Solutions? Validation: Fluids Example Stoke’s Flow MARTIN, SOUSA, TRAN (AFRL/RQRS) DISTRIBUTION A - APPROVED FOR PUBLIC RELEASE...Convergence Tests Converged Math → Irrelevant Solutions? Must be Aware of Valid Assumption Regions Validation: Fluids Example Stoke’s Flow Potential...AND VALIDATION Verification: Asymptotic Models → Analytical Solutions Yields Exact Convergence Tests Converged Math → Irrelevant Solutions? Must be
2017-07-01
this report are not to be construed as an official Department of the Army position unless so designated by other authorized documents. DESTROY...non-destructively evaluate fiber distributions, orientation, and FRC posttest damage. This technique allows for a closer to meso scale investigation...performance all the while optimizing the material and improving desired performance by designing materials based on individual constituent
2011-09-01
Earthquake, Pakistan, Flood, Emergency Response Operations, International Community, HA/DR, United Nations , FRC, NDMA , ICT 16. PRICE CODE 17. SECURITY...Registration Authority NATO North Atlantic Treaty Organization NDMA National Disaster and Management Authority NDMC National Disaster Management...complicates relief efforts. 6 NDMA Pakistan, “Pakistan Floods-Summary of Damages,” No Author. Accessed 24
Ray, Jayashree; Waters, R. Jordan; Skerker, Jeffrey M.; ...
2015-05-14
Cupriavidus basilensis 4G11 was isolated from groundwater at the Oak Ridge Field Research Center (FRC) site. Here, we report the complete genome sequence and annotation of Cupriavidus basilensis 4G11. The genome contains 8,421,483 bp, 7,661 predicted protein-coding genes, and a total GC content of 64.4%.
Lawn Care Pesticides. Risks Remain Uncertain While Prohibited Safety Claims Continue
1990-03-23
Trade Commission (FrC), under its own legislative authority to protect consumers against false and deceptive advertising , can take enforcement action...vides to the public about the safety of its products, federal enforcement actions taken against lawn care pesticide safety advertising claims, and...in reassessing the risks of these pesticides. FIFRA also authorizes EPA to take enforcement action against advertising claims made by pesticide
Utility of Acoustic Pharyngometry for the Diagnosis of Obstructive Sleep Apnea.
Kendzerska, Tetyana; Grewal, Monica; Ryan, Clodagh M
2016-11-01
Owing to resource limitations, the testing of patients for obstructive sleep apnea (OSA) is often delayed. There is a need to accurately triage and expedite testing in those with a high pretest probability of OSA. Acoustic pharyngometry is a simple, noninvasive technique used to assess the upper airway cross-sectional area (UA-XSA), which is known to be reduced in those with OSA. To determine the discriminative ability and predictive value of UA-XSA measurements by acoustic pharyngometry for OSA. We conducted a cross-sectional study with a clinical cohort of consecutive adults with suspected OSA who had undergone both polysomnography and acoustic pharyngometry. OSA was defined as an apnea-hypopnea index greater than or equal to 5. Multivariable logistic regression analyses and receiver operating characteristic curves were used. The cohort included 576 subjects, 87% of whom had OSA and 64% of whom were men. The subjects' median body mass index (BMI) was 30.3 kg/m 2 , and their median age was 57 years. The median UA-XSA at FRC when sitting was significantly smaller in those with OSA compared with those without OSA (3.3 cm 2 [interquartile range, 2.7-3.8] vs. 3.7 cm 2 [interquartile range, of 2.9-4.2]). When the analysis was controlled for age, sex, BMI, and comorbidities, the odds of OSA increased for every 1-cm 2 decrease in the mean UA-XSA FRC when sitting (odds ratio, 1.62; 95% confidence interval, 1.23-2.13). The mean UA-XSA provided fair discrimination for OSA (area under the curve, 0.60). A cutoff value of 3.75 cm 2 , the point with the best sum of sensitivity and specificity, had sensitivity of 73% and specificity of 46%. The magnitude of the incremental discriminative value of UA-XSA over clinical variables (age, sex, BMI, and comorbidities) was small and nonsignificant (P = 0.5). The mean UA-XSA at FRC when sitting or supine provided no further significant advantage over clinical variables for the discernment of OSA.
2012-01-01
Background A high perioperative inspiratory oxygen fraction (FiO2) may reduce the frequency of surgical site infection. Perioperative atelectasis is caused by absorption, compression and reduced function of surfactant. It is well accepted, that ventilation with 100% oxygen for only a few minutes is associated with significant formation of atelectasis. However, it is still not clear if a longer period of 80% oxygen results in more atelectasis compared to a low FiO2. Our aim was to assess if a high FiO2 is associated with impaired oxygenation and decreased pulmonary functional residual capacity (FRC). Methods Thirty-five patients scheduled for laparotomy for ovarian cancer were randomized to receive either 30% oxygen (n = 15) or 80% oxygen (n = 20) during and for 2 h after surgery. The oxygenation index (PaO2/FiO2) was measured every 30 min during anesthesia and 90 min after extubation. FRC was measured the day before surgery and 2 h after extubation by a rebreathing method using the inert gas SF6. Results Five min after intubation, the median PaO2/FiO2 was 69 kPa [53-71] in the 30%-group vs. 60 kPa [47-69] in the 80%-group (P = 0.25). At the end of anesthesia, the PaO2/FiO2 was 58 kPa [40-70] vs. 57 kPa [46-67] in the 30%- and 80%-group, respectively (P = 0.10). The median FRC was 1993 mL [1610-2240] vs. 1875 mL [1545-2048] at baseline and 1615 mL [1375-2318] vs. 1633 mL [1343-1948] postoperatively in the 30%- and 80%-group, respectively (P = 0.70). Conclusion We found no significant difference in oxygenation index or functional residual capacity between patients given 80% and 30% oxygen for a period of approximately 5 hours. Trial registration ClinicalTrials.gov Identifier: NCT00637936. PMID:22840231
1966-04-07
Fred W. Haise Jr. was a research pilot and an astronaut for the National Aeronautics and Space Administration from 1959 to 1979. He began flying at the Lewis Research Center in Cleveland, Ohio (today the Glenn Research Center), in 1959. He became a research pilot at the NASA Flight Research Center (FRC), Edwards, Calif., in 1963, serving NASA in that position for three years until being selected to be an astronaut in 1966 His best-known assignment at the FRC (later redesignated the Dryden Flight Research Center) was as a lifting body pilot. Shortly after flying the M2-F1 on a car tow to about 25 feet on April 22, 1966, he was assigned as an astronaut to the Johnson Space Center in Houston, Texas. While at the FRC he had also flown a variety of other research and support aircraft, including the variable-stability T-33A to simulate the M2-F2 heavyweight lifting body, some light aircraft including the Piper PA-30 to evaluate their handling qualities, the Apache helicopter, the Aero Commander, the Cessna 310, the Douglas F5D, the Lockheed F-104 and T-33, the Cessna T-37, and the Douglas C-47. After becoming an astronaut, Haise served as a backup crewmember for the Apollo 8, 11, and 16 missions. He flew on the aborted Apollo 13 lunar mission in 1970, spending 142 hours and 54 minutes in space before returning safely to Earth. In 1977, he was the commander of three free flights of the Space Shuttle prototype Enterprise when it flew its Approach and Landing Tests at Edwards Air Force Base, Calif. Meanwhile, from April 1973 to January 1976, Haise served as the Technical Assistant to the Manager of the Space Shuttle Orbiter Project. In 1979, he left NASA to become the Vice President for Space Programs with the Grumman Aerospace Corporation. He then served as President of Grumman Technical Services, an operating division of Northrop Grumman Corporation, from January 1992 until his retirement. Haise was born in Biloxi, Miss., on November 14, 1933. He underwent flight traini
Photoelastic stress analysis of different prefabricated post-and-core materials.
Asvanund, Pattapon; Morgano, Steven M
2011-01-01
The purpose of this study was to investigate stress developed by a combination of a stainless steel post or a fiber-reinforced resin post with a silver amalgam core or a composite resin core. Two-dimensional photoelastic models were used to simulate root dentin. Posts (ParaPost XT and ParaPost-FiberWhite) were cemented with a luting agent (RelyX Unicem). Silver amalgam cores and composite resin cores were fabricated on the posts. Complete crowns were fabricated and cemented on the cores. Each model was analyzed with 2 force magnitudes and in 2 directions. Fringe orders were recorded and compared using ANOVA (p=0.05) and the Scheffe's test. With vertical force, no stress differences occurred among the 4 groups (p=0.159). With a 30-degree force, there was stress differences among the 4 groups (p<0.001). The combination of a fiber-reinforced post and composite resin core could potentially reduce stresses within the radicular dentin when angled loads are applied.
Signore, Antonio; Benedicenti, Stefano; Kaitsas, Vassilios; Barone, Michele; Angiero, Francesca; Ravera, Giambattista
2009-02-01
This retrospective study investigated the clinical effectiveness over up to 8 years of parallel-sided and of tapered glass-fiber posts, in combination with either hybrid composite or dual-cure composite resin core material, in endodontically treated, maxillary anterior teeth covered with full-ceramic crowns. The study population comprised 192 patients and 526 endodontically treated teeth, with various degrees of hard-tissue loss, restored by the post-and-core technique. Four groups were defined based on post shape and core build-up materials, and within each group post-and-core restorations were assigned randomly with respect to root morphology. Inclusion criteria were symptom-free endodontic therapy, root-canal treatment with a minimum apical seal of 4mm, application of rubber dam, need for post-and-core complex because of coronal tooth loss, and tooth with at least one residual coronal wall. Survival rate of the post-and-core restorations was determined using Kaplan-Meier statistical analysis. The restorations were examined clinically and radiologically; mean observation period was 5.3 years. The overall survival rate of glass-fiber post-and-core restorations was 98.5%. The survival rate for parallel-sided posts was 98.6% and for tapered posts was 96.8%. Survival rates for core build-up materials were 100% for dual-cure composite and 96.8% for hybrid light-cure composite. For both glass-fiber post designs and for both core build-up materials, clinical performance was satisfactory. Survival was higher for teeth retaining four and three coronal walls.
1988-09-01
environmental branch of their hazardous waste activities. Trend Analysis Before EPA had finished promulgating regulations designed to address all aspects of... Cotonal do"yd B 100 (454) Aminhinm cait-inail. 1) 5i,0)) (2.2170) CJpFrc Meetet B 100( 45>4) Ai-ncniir 0liic1Ŕ. Li 5.0iA1 (2.2 70) C.Ac acatoersenita 8 1
Capillary Discharge Thruster Experiments and Modeling (Briefing Charts)
2016-06-01
Martin1 ERC INC.1, IN-SPACE PROPULSION BRANCH, AIR FORCE RESEARCH LABORATORY EDWARDS AIR FORCE BASE, CA USA Electric propulsion systems June 2016... PROPULSION MODELS & EXPERIMENTS Spacecraft Propulsion Relevant Plasma: From hall thrusters to plumes and fluxes on components Complex reaction physics i.e... Propulsion Plumes FRC Chamber Environment R.S. MARTIN (ERC INC.) DISTRIBUTION A: APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED; PA# 16279 3 / 30 ELECTRIC
Modeling of Diffusion Based Correlations Between Heart Rate Modulations and Respiration Pattern
2001-10-25
1 of 4 MODELING OF DIFFUSION BASED CORRELATIONS BETWEEN HEART RATE MODULATIONS AND RESPIRATION PATTERN R.Langer,(1) Y.Smorzik,(2) S.Akselrod,(1...generations of the bronchial tree. The second stage describes the oxygen diffusion process from the pulmonary gas in the alveoli into the pulmonary...patterns (FRC, TV, rate). Keywords – Modeling, Diffusion , Heart Rate fluctuations I. INTRODUCTION Under a whole-body management perception, the
Realization of FRC interior and exterior furniture
NASA Astrophysics Data System (ADS)
Šonka, Š.; Frantová, M.; Štemberk, P.; Havrda, J.; Janouch, P.
2017-09-01
This article deals with the implementation of fibre reinforced concrete for interior and exterior furniture. The use of fibre reinforced concrete for non-traditional and small structures brings some specifics in design and realization. These are, in particular, the design of a suitable mixture, the choice of the shape of the structure in relation to the technological possibilities of realization, the static effects and finally the actual production of the element.
1980-01-01
producers under a state law of 1978. Until the regulations under PURPA Title II (the National Energy Act of 1978) are promulgated and the PUC reviews this...hour (rWi); end it is FURTr.R ORDERMD, that the Corumission will re-examine th4 PURPA issues in this proceedirg upon the issuance of rules by the F-RC
Langmuir probe diagnostic suite in the C-2 field-reversed configuration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roche, T., E-mail: troche@trialphaenergy.com; Armstrong, S.; Knapp, K.
2014-11-15
Several in situ probes have been designed and implemented into the diagnostic array of the C-2 field-reversed configuration (FRC) at Tri Alpha Energy [M. Tuszewski et al. (the TAE Team), Phys. Rev. Lett. 108, 255008 (2012)]. The probes are all variations on the traditional Langmuir probe. They include linear arrays of triple probes, linear arrays of single-tipped swept probes, a multi-faced Gundestrup probe, and an ion-sensitive probe. The probes vary from 5 to 7 mm diameter in size to minimize plasma perturbations. They also have boron nitride outer casings that prevent unwanted electrical breakdown and reduce the introduction of impurities.more » The probes are mounted on motorized linear-actuators allowing for programmatic scans of the various plasma parameters over the course of several shots. Each probe has a custom set of electronics that allows for measurement of the desired signals. High frequency ( > 5MHz) analog optical-isolators ensure that plasma parameters can be measured at sub-microsecond time scales while providing electrical isolation between machine and data acquisition systems. With these probes time-resolved plasma parameters (temperature, density, spatial potential, flow, and electric field) can be directly/locally measured in the FRC jet and edge/scrape-off layer.« less
The impact of surfactant replacement therapy on cerebral and systemic circulation and lung function.
Schipper, J A; Mohammad, G I; van Straaten, H L; Koppe, J G
1997-03-01
The influence of surfactant administration on cerebral and systemic circulation and on lung function was evaluated in 12 premature mechanically ventilated infants (mean birth weight 1,560 +/- 770 g, mean gestational age 30.0 +/- 3.2 weeks) with respiratory distress syndrome (RDS) receiving surfactant replacement therapy. We measured mean cerebral blood flow velocity (MCBFV), heart rate (HR), mean arterial pressure (MAP), static compliance (Crs), resistance of respiratory system (Rrs), functional residual capacity (FRC) and fraction of inspired oxygen (FiO2). In addition to a very low compliance and a moderately elevated resistance of the respiratory system a significant drop in MAP, HR, MCBFV and FiO2 was noticed after surfactant administration. After 30 min HR, MAP and MCBFV values returned to baseline levels. We postulate that the drop in MCBFV, MAP, HR and FiO2 with a minor, though not significant improvement of the FRC can most likely be explained by a "relative" hypovolaemia in other organs and parts of the body due to expansion of the lung vascular bed. Compensation for the redistribution of circulatory volume occurred within several minutes. Blood pressure control and treatment of hypovolaemia is mandatory before surfactant is administered. In RDS patients there is a significant drop of MAP, HR, MCBFV and FiO2 after bolus surfactant administration.
Laboratory studies of magnetized collisionless flows and shocks using accelerated plasmoids
NASA Astrophysics Data System (ADS)
Weber, T. E.; Smith, R. J.; Hsu, S. C.
2015-11-01
Magnetized collisionless shocks are thought to play a dominant role in the overall partition of energy throughout the universe, but have historically proven difficult to create in the laboratory. The Magnetized Shock Experiment (MSX) at LANL creates conditions similar to those found in both space and astrophysical shocks by accelerating hot (100s of eV during translation) dense (1022 - 1023 m-3) Field Reversed Configuration (FRC) plasmoids to high velocities (100s of km/s); resulting in β ~ 1, collisionless plasma flows with sonic and Alfvén Mach numbers of ~10. The FRC subsequently impacts a static target such as a strong parallel or anti-parallel (reconnection-wise) magnetic mirror, a solid obstacle, or neutral gas cloud to create shocks with characteristic length and time scales that are both large enough to observe yet small enough to fit within the experiment. This enables study of the complex interplay of kinetic and fluid processes that mediate cosmic shocks and can generate non-thermal distributions, produce density and magnetic field enhancements much greater than predicted by fluid theory, and accelerate particles. An overview of the experimental capabilities of MSX will be presented, including diagnostics, selected recent results, and future directions. Supported by the DOE Office of Fusion Energy Sciences under contract DE-AC52-06NA25369.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osin, D.; Schindler, T., E-mail: dosin@trialphaenergy.com
2016-11-15
A dual wavelength imaging system has been developed and installed on C-2U to capture 2D images of a He jet in the Scrape-Off Layer (SOL) of an advanced beam-driven Field-Reversed Configuration (FRC) plasma. The system was designed to optically split two identical images and pass them through 1 nm FWHM filters. Dual wavelength images are focused adjacent on a large format CCD chip and recorded simultaneously with a time resolution down to 10 μs using a gated micro-channel plate. The relatively compact optical system images a 10 cm plasma region with a spatial resolution of 0.2 cm and can bemore » used in a harsh environment with high electro-magnetic noise and high magnetic field. The dual wavelength imaging system provides 2D images of either electron density or temperature by observing spectral line pairs emitted by He jet atoms in the SOL. A large field of view, combined with good space and time resolution of the imaging system, allows visualization of macro-flows in the SOL. First 2D images of the electron density and temperature observed in the SOL of the C-2U FRC are presented.« less
Factors Affecting Lung Function: A Review of the Literature.
Talaminos Barroso, Alejandro; Márquez Martín, Eduardo; Roa Romero, Laura María; Ortega Ruiz, Francisco
2018-06-01
Lung function reference values are traditionally based on anthropometric factors, such as weight, height, sex, and age. FVC and FEV 1 decline with age, while volumes and capacities, such as RV and FRC, increase. TLC, VC, RV, FVC and FEV 1 are affected by height, since they are proportional to body size. This means that a tall individual will experience greater decrease in lung volumes as they get older. Some variables, such as FRC and ERV, decline exponentially with an increase in weight, to the extent that tidal volume in morbidly obese patients can be close to that of RV. Men have longer airways than women, causing greater specific resistance in the respiratory tract. The increased work of breathing to increase ventilation among women means that their consumption of oxygen is higher than men under similar conditions of physical intensity. Lung volumes are higher when the subject is standing than in other positions. DLCO is significantly higher in supine positions than in sitting or standing positions, but the difference between sitting and standing positions is not significant. Anthropometric characteristics are insufficient to explain differences in lung function between different ethnic groups, underlining the importance of considering other factors in addition to the conventional anthropometric measurements. Copyright © 2018 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.
Development of 1D Liner Compression Code for IDL
NASA Astrophysics Data System (ADS)
Shimazu, Akihisa; Slough, John; Pancotti, Anthony
2015-11-01
A 1D liner compression code is developed to model liner implosion dynamics in the Inductively Driven Liner Experiment (IDL) where FRC plasmoid is compressed via inductively-driven metal liners. The driver circuit, magnetic field, joule heating, and liner dynamics calculations are performed at each time step in sequence to couple these effects in the code. To obtain more realistic magnetic field results for a given drive coil geometry, 2D and 3D effects are incorporated into the 1D field calculation through use of correction factor table lookup approach. Commercial low-frequency electromagnetic fields solver, ANSYS Maxwell 3D, is used to solve the magnetic field profile for static liner condition at various liner radius in order to derive correction factors for the 1D field calculation in the code. The liner dynamics results from the code is verified to be in good agreement with the results from commercial explicit dynamics solver, ANSYS Explicit Dynamics, and previous liner experiment. The developed code is used to optimize the capacitor bank and driver coil design for better energy transfer and coupling. FRC gain calculations are also performed using the liner compression data from the code for the conceptual design of the reactor sized system for fusion energy gains.
Post-processing of metal matrix composites by friction stir processing
NASA Astrophysics Data System (ADS)
Sharma, Vipin; Singla, Yogesh; Gupta, Yashpal; Raghuwanshi, Jitendra
2018-05-01
In metal matrix composites non-uniform distribution of reinforcement particles resulted in adverse affect on the mechanical properties. It is of great interest to explore post-processing techniques that can eliminate particle distribution heterogeneity. Friction stir processing is a relatively newer technique used for post-processing of metal matrix composites to improve homogeneity in particles distribution. In friction stir processing, synergistic effect of stirring, extrusion and forging resulted in refinement of grains, reduction of reinforcement particles size, uniformity in particles distribution, reduction in microstructural heterogeneity and elimination of defects.
Clinical studies of fiber posts: a literature review.
Cagidiaco, Maria C; Goracci, Cecilia; Garcia-Godoy, Franklin; Ferrari, Marco
2008-01-01
This literature review aimed to find answers to relevant questions regarding the clinical outcome of endontically treated teeth restored with fiber posts. All clinical studies published since 1990 in journals indexed in MEDLINE were retrieved by searching PubMed with the query terms "fiber posts and clinical studies." The reference list of the collected articles was also screened for further relevant citations. The strength of the evidence provided by the reviewed papers was assessed according to the criteria of evidence-based dentistry. Five randomized controlled trials (RCTs) on fiber posts have been published in peer-reviewed journals. A meta-analysis is not applicable to these studies since they do not address the same specific clinical question. Retrospective and prospective trials without controls are also available. Two RCTs indicate that fiber-reinforced composite posts outperform metal posts in the restoration of endontically treated teeth. However, this evidence cannot be considered as conclusive. Longer-term RCTs would be desirable. The placement of a fiber-reinforced composite post protects against failure, especially under conditions of extensive coronal destruction. The most common type of failure with fiber-reinforced composite posts is debonding.
Luo, Gang; Angelidaki, Irini
2014-09-01
The present study investigated the changes of bacterial community composition including bacterial pathogens along a biogas plant, i.e. from the influent, to the biogas reactor and to the post-digester. The effects of post-digestion temperature and time on the changes of bacterial community composition and bacterial pathogens were also studied. Microbial analysis was made by Ion Torrent sequencing of the PCR amplicons from ethidium monoazide treated samples, and ethidium monoazide was used to cleave DNA from dead cells and exclude it from PCR amplification. Both similarity and taxonomic analysis showed that the bacterial community composition in the influent was changed after anaerobic digestion. Firmicutes were dominant in all the samples, while Proteobacteria decreased in the biogas reactor compared with the influent. Variations of bacterial community composition in the biogas reactor with time were also observed. This could be attributed to varying composition of the influent. Batch experiments showed that the methane recovery from the digested residues (obtained from biogas reactor) was mainly related with post-digestion temperature. However, post-digestion time rather than temperature had a significant effect on the changes of bacterial community composition. The changes of bacterial community composition were also reflected in the changes of relative abundance of bacterial pathogens. The richness and relative abundance of bacterial pathogens were reduced after anaerobic digestion in the biogas reactor. It was found in batch experiments that bacterial pathogens showed the highest relative abundance and richness after 30 days' post-digestion. Streptococcus bovis was found in all the samples. Our results showed that special attention should be paid to the post-digestion since the increase in relative abundance of bacterial pathogens after post-digestion might reflect regrowth of bacterial pathogens and limit biosolids disposal vectors. Copyright © 2014 Elsevier Ltd. All rights reserved.
Albashaireh, Zakereyya S; Ghazal, Muhamad; Kern, Matthias
2010-01-01
Several post surface treatments with or without the application of a bonding agent have been recommended to improve the bond strength of resin cements to posts. A regimen that produces the maximum bond strength of glass fiber-reinforced composite resin posts has not been verified. The purpose of this study was to evaluate the influence of post surface conditioning methods and artificial aging on the retention and microleakage of adhesively luted glass fiber-reinforced composite resin posts. Seventy-two endodontically treated single-rooted teeth were prepared for glass fiber-reinforced composite resin posts. The posts were submitted to 3 different surface treatments (n=24), including no treatment, etching with phosphoric acid, and airborne-particle abrasion. Subgroups of the posts (n=8) were then allocated for 3 different experimental conditions: no artificial aging, no bonding agent; no artificial aging, bonding agent; or artificial aging, bonding agent. The posts were luted with resin cement (Calibra). Post retention was measured in tension at a crosshead speed of 2 mm/min. The posts assigned for microleakage investigation were placed in fuchsin dye for 72 hours. The dislodged posts and the post spaces were examined microscopically to evaluate the mode of failure and explore the microleakage. Data were analyzed by 2-way ANOVA followed by Tukey HSD test (alpha=.05). The mean (SD) retention values for test groups ranged from 269 (63.8) to 349 (52.2) N. The retention values of the airborne-particle-abrasion group were significantly higher than those of the acidic-treatment and no-treatment groups. The application of bonding agent on the post surface produced no significant influence on retention. The mean retention values after artificial aging were significantly higher than without artificial aging. Microscopic evaluation demonstrated that the failure mode was primarily mixed. Treating the surface of the posts with phosphoric acid for 15 seconds before cementation produced no significant improvement in post retention. Airborne-particle abrasion of the surface of the post significantly improved post retention. Copyright 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
In vitro evaluation of the retention of composite fiber and stainless steel posts.
Gallo, John R; Miller, Troy; Xu, Xiaoming; Burgess, John O
2002-03-01
This study compared the tensile retentive strength of composite fiber-reinforced dowels luted with a resin cement to stainless steel dowels luted with zinc phosphate cement. The crowns of 40 extracted human mandibular premolars were removed with a separating disc 1-mm coronal to the cementoenamel junction. The teeth were randomly divided into 4 groups (n = 10). A post space was prepared in each specimen to a depth of 9 mm, using the drill supplied by the respective manufacturer. For the stainless steel post group, 1.25-mm-diameter posts were cemented with zinc phosphate cement. For the composite fiber reinforced groups, posts with diameters of 1.00, 1.25, and 1.50 mm were luted with a Bisphenol A-Glycidyl Methacrylate (BIS-GMA) resin bonding system (Jeneric/Pentron, Wallingford, CT) according to manufacturer specifications. The specimens were stored in a sealed container with a moist environment for 24 hours, placed in a fixture in an 801 Materials Test Systems (MTS) machine (MTS Systems Corp, Minneapolis, MN), and loaded in tension at a rate of 5.0 mm/min until failure. Differences among the 4 groups were determined using a one-way analysis of variance and Tukey-B post-hoc tests (alpha = 0.05). The mean loads to failure ranged from 43.9 +/- 10.4 kg for the stainless steel dowel group to 19.9 +/- 5.7 kg for the composite fiber-reinforced 1.00-mm-diameter group. The stainless steel post luted with zinc phosphate cement provided significantly greater tensile resistance than all composite fiber dowel groups. The retention of the 1.00-mm composite fiber-reinforced post was significantly less than the remaining groups. Under the conditions of this study, the stainless steel dowel luted with zinc phosphate cement provided significantly greater retention. Copyright 2002 by The American College of Prosthodontists.
LLRV in flight and landing on ramp
NASA Technical Reports Server (NTRS)
1960-01-01
This 26-second video clip shows the LLRV flying and landing. The LLRV's, humorously referred to as 'flying bedsteads,' were created by a predecessor of the NASA Dryden Flight Research Center and Bell Aerosystems Company, Niagra Falls, New York, to study and analyze piloting techniques needed to fly and land the tiny Apollo Lunar Module in the Moon's airless environment. (Dryden was known simply as the NASA Flight Research Center from 1959 to 1976.) Success of the LLRV's led to the building of three Lunar Landing Training Vehicles (LLTV) used by Apollo astronauts at the Manned Spacecraft Center, Houston, Texas, predecessor of the NASA Johnson Space Center. Apollo 11 astronaut, Neil Armstrong -- first human to step onto the Moon's surface -- said the mission would not have been successful without the type of simulation that resulted from the LLRV's. When Apollo planning was underway in 1960, NASA was looking for a simulator to profile the descent to the Moon's surface. Three concepts developed: an electronic simulator, a tethered device, and the ambitious Flight Research Center (FRC) contribution, a free-flying vehicle. All three became serious projects, but eventually the FRC's LLRV became the most significant one. Hubert Drake is credited with originating the idea, while Donald Bellman and Gene Matranga were senior engineers on the project, with Bellman the project manager. After conceptual planning and meetings with engineers from Bell Aerosystems, a company with experience in vertical takeoff and landing (VTOL) aircraft, NASA issued Bell a $50,000 study contract in December 1961. Bell had independently conceived a similar, free-flying simulator, and out of this study came the headquarters' endorsement of the LLRV concept, resulting in a $3.6 million production contract awarded to Bell February 1, 1963, for delivery of the first of two vehicles for flight studies at the FRC within 14 months. Built of aluminum alloy trusses and shaped like a giant four-legged bedstead, the vehicle was to simulate a lunar landing profile. To do this, the LLRV had a General Electric CF-700-2V turbofan engine mounted vertically in a gimbal, with 4200 pounds of thrust. The engine got the vehicle up to the test altitude and was then throttled back to support five-sixths of the vehicle's weight, simulating the reduced gravity of the Moon. Two hydrogen peroxide lift rockets with thrust that could be varied from 100 to 500 pounds handled the LLRV's rate of descent and horizontal movement. Sixteen smaller hydrogen peroxide rockets, mounted in pairs, gave the pilot control in pitch, yaw, and roll. As safety backups on the LLRV, six 500-pound rockets could take over the lift function and stabilize the craft for a moment if the main jet engine failed. The pilot had a zero-zero ejection seat that would then lift him away to safety. The two LLRV's were shipped from Bell to the FRC in April 1964, with program emphasis on vehicle No. 1. It was first readied for captured flight on a tilt-table affair. The scene then shifted to the old South Base area of Edwards. On the day of the first flight, October 30, 1964, research pilot Joe Walker flew it three times for a total of just under 60 seconds to a peak altitude of ten feet (three meters). Later flights were shared between Walker, another Center pilot named Don Mallick, the Army's Jack Kleuver, NASA Manned Spacecraft Center, Houston, Texas, pilots Joseph Algranti and H.E. 'Bud' Ream. NASA had accumulated enough data from the LLRV flight program at the FRC by mid-1966 to give Bell a contract to deliver three LLTVs at a cost of $2.5 million each. In December 1966 vehicle No. 1 was shipped to Houston, followed by No. 2 in January 1967, within weeks of its first flight. Modifications already made to No. 2 had given the pilot a three-axis side control stick and a more restrictive cockpit view, both features of the real Lunar Module that would later be flown by the astronauts down to the Moon's surface. When the LLRV's arrived at Houston, where research pilots would learn how to become LLTV instructor pilots, No. 2 had been flown just seven times while No. 1, the veteran, had a total of 198 flights. In December 1967, the first of the LLTV's joined the FRC's LLRV's to eventually make up the five-vehicle training and simulator fleet. Three of the five vehicles were later destroyed in crashes at Houston - LLRV No. 1 in May 1968 and two LLTV's, in December 1968 and January 1971. The two accidents in 1968, before the first lunar landing, did not deter Apollo program managers who enthusiastically relied on the vehicles for simulation and training. Donald 'Deke' Slayton, then NASA's astronaut chief, said there was no other way to simulate a Moon landing except by flying the LLTV. LLRV No. 2 was eventually returned to Dryden, where it is on display as a silent artifact of the Center's contribution to the Apollo program.
NASA Technical Reports Server (NTRS)
1960-01-01
This 24-second video clip shows the LLRV pilot strapping in and flying the vehicle. The LLRV's, humorously referred to as 'flying bedsteads,' were created by a predecessor of the NASA Dryden Flight Research Center and Bell Aerosystems Company, Niagra Falls, New York, to study and analyze piloting techniques needed to fly and land the tiny Apollo Lunar Module in the Moon's airless environment. (Dryden was known simply as the NASA Flight Research Center from 1959 to 1976.) Success of the LLRV's led to the building of three Lunar Landing Training Vehicles (LLTV) used by Apollo astronauts at the Manned Spacecraft Center, Houston, Texas, predecessor of the NASA Johnson Space Center. Apollo 11 astronaut, Neil Armstrong -- first human to step onto the Moon's surface -- said the mission would not have been successful without the type of simulation that resulted from the LLRV's. When Apollo planning was underway in 1960, NASA was looking for a simulator to profile the descent to the Moon's surface. Three concepts developed: an electronic simulator, a tethered device, and the ambitious Flight Research Center (FRC) contribution, a free-flying vehicle. All three became serious projects, but eventually the FRC's LLRV became the most significant one. Hubert Drake is credited with originating the idea, while Donald Bellman and Gene Matranga were senior engineers on the project, with Bellman the project manager. After conceptual planning and meetings with engineers from Bell Aerosystems, a company with experience in vertical takeoff and landing (VTOL) aircraft, NASA issued Bell a $50,000 study contract in December 1961. Bell had independently conceived a similar, free-flying simulator, and out of this study came the headquarters' endorsement of the LLRV concept, resulting in a $3.6 million production contract awarded to Bell February 1, 1963, for delivery of the first of two vehicles for flight studies at the FRC within 14 months. Built of aluminum alloy trusses and shaped like a giant four-legged bedstead, the vehicle was to simulate a lunar landing profile. To do this, the LLRV had a General Electric CF-700-2V turbofan engine mounted vertically in a gimbal, with 4200 pounds of thrust. The engine got the vehicle up to the test altitude and was then throttled back to support five-sixths of the vehicle's weight, simulating the reduced gravity of the Moon. Two hydrogen peroxide lift rockets with thrust that could be varied from 100 to 500 pounds handled the LLRV's rate of descent and horizontal movement. Sixteen smaller hydrogen peroxide rockets, mounted in pairs, gave the pilot control in pitch, yaw, and roll. As safety backups on the LLRV, six 500-pound rockets could take over the lift function and stabilize the craft for a moment if the main jet engine failed. The pilot had a zero-zero ejection seat that would then lift him away to safety. The two LLRV's were shipped from Bell to the FRC in April 1964, with program emphasis on vehicle No. 1. It was first readied for captured flight on a tilt-table affair. The scene then shifted to the old South Base area of Edwards. On the day of the first flight, October 30, 1964, research pilot Joe Walker flew it three times for a total of just under 60 seconds to a peak altitude of ten feet (three meters). Later flights were shared between Walker, another Center pilot named Don Mallick, the Army's Jack Kleuver, NASA Manned Spacecraft Center, Houston, Texas, pilots Joseph Algranti and H.E. 'Bud' Ream. NASA had accumulated enough data from the LLRV flight program at the FRC by mid-1966 to give Bell a contract to deliver three LLTV's at a cost of $2.5 million each. In December 1966 vehicle No. 1 was shipped to Houston, followed by No. 2 in January 1967, within weeks of its first flight. Modifications already made to No. 2 had given the pilot a three-axis side control stick and a more restrictive cockpit view, both features of the real Lunar Module that would later be flown by the astronauts down to the Moon's surface. When the LLRV's arrived at Houston, where research pilots would learn how to become LLTV instructor pilots, No. 2 had been flown just seven times while No. 1, the veteran, had a total of 198 flights. In December 1967, the first of the LLTV's joined the FRC's LLRV's to eventually make up the five-vehicle training and simulator fleet. Three of the five vehicles were later destroyed in crashes at Houston - LLRV No. 1 in May 1968 and two LLTVs, in December 1968 and January 1971. The two accidents in 1968, before the first lunar landing, did not deter Apollo program managers who enthusiastically relied on the vehicles for simulation and training. Donald 'Deke' Slayton, then NASA's astronaut chief, said there was no other way to simulate a Moon landing except by flying the LLTV. LLRV No. 2 was eventually returned to Dryden, where it is on display as a silent artifact of the Center's contribution to the Apollo program.
Post-Fire Recovery in Coastal Sage Scrub: Seed Rain and Community Trajectory.
Conlisk, Erin; Swab, Rebecca; Martínez-Berdeja, Alejandra; Daugherty, Matthew P
2016-01-01
Disturbance is a primary mechanism structuring ecological communities. However, human activity has the potential to alter the frequency and intensity of natural disturbance regimes, with subsequent effects on ecosystem processes. In Southern California, human development has led to increased fire frequency close to urban areas that can form a positive feedback with invasive plant spread. Understanding how abiotic and biotic factors structure post-fire plant communities is a critical component of post-fire management and restoration. In this study we considered a variety of mechanisms affecting post-fire vegetation recovery in Riversidean sage scrub. Comparing recently burned plots to unburned plots, we found that burning significantly reduced species richness and percent cover of exotic vegetation the first two years following a 100-hectare wildfire. Seed rain was higher in burned plots, with more native forb seeds, while unburned plots had more exotic grass seeds. Moreover, there were significant correlations between seed rain composition and plant cover composition the year prior and the year after. Collectively, this case study suggests that fire can alter community composition, but there was not compelling evidence of a vegetation-type conversion. Instead, the changes in the community composition were temporary and convergence in community composition was apparent within two years post-fire.
Glass fiber reinforced composite resin as an intracanal post--a clinical study.
Subramaniam, Priya; Babu, K L Girish; Sunny, Raju
2008-01-01
Restoration of primary incisors, which have been severely damaged by early childhood caries or trauma, is a difficult task for the pediatric dentist. With the introduction of new adhesive systems and restorative materials, alternative approaches for treating these teeth have been proposed. Ten healthy children aged between 3-4 years who had 28 grossly destructed primary maxillary incisors requiring intra canal retention were selected for the study. Following root canal treatment, either a Glass Fiber Reinforced Composite Resin (GFRCR everStick,, Finland) or an omega shaped stainless steel wire were placed as intracanal posts in these teeth. Flowable composite was used for cementation of posts and also to build up the coronal structure using celluloid strip crowns. Both types of intracanal posts were evaluated for retention and marginal adaptation at 1, 6 and 12 months. The data obtained was subjected to statistical analysis. GFRCR intracanal posts showed better retention and marginal adaptation than omega shaped stainless steel wire posts.
2005-03-18
Lepomis macrochirus). have been disinfected with chloramines The threshold for a toxicity alarm by was not determined. Biomonitor users the USACEHR...residual solution. This caused an elevated chlorine from water disinfected with chlorine level (measured at 0.08 FRC) chloramines . In testing with a rapid...have been disinfected A Handbook, Volume 2, 8. Kluwer with chloramines . Academic/Plenum Publishers, New York, NY, pp 123-141. 5. Recommendations
NASA Technical Reports Server (NTRS)
Schwarzenberg, M.; Pippia, P.; Meloni, M. A.; Cossu, G.; Cogoli-Greuter, M.; Cogoli, A.
1998-01-01
The purpose of this paper is to present the results obtained in our laboratory with both instruments, the FFM [free fall machine] and the RPM [random positioning machine], to compare them with the data from earlier experiments with human lymphocytes conducted in the FRC [fast rotating clinostat] and in space. Furthermore, the suitability of the FFM and RPM for research in gravitational cell biology is discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, Wang; Wang, Haiou; Kuenne, Guido
This supplementary material complements the article and provides additional information to the chemical mechanism used in this work, boundary conditions for the LES con guration and table generation, comparisons of axial velocities, results from a LES/ nite-rate chemistry (FRC) approach, and results from the LES/DTF/SPF approach with a particular chemistry table that is generated using a single strained premixed amelet solution.
Risk Management Approach & Progress in Cd and Cr6+ Elimination
2014-11-18
Documentation Available by 2015? Gaps Conversion Coating- Aluminum Avionics/Electrical- Class 3 9 7 Medium yes- joint service/OEM/ NASA effort to...Optimized conditions validated by NASA . – FRC validation: immersion process – Based on data from the lab Surtec 650V optimization, an 1800-gallon tank...acting similarly, 650V not • Plans: scale up to 80 gallon process line; assess Metalast TCP/HF- EPA and Henkel products; further study 650V
Directed Energy HPM, PP, & PPS Efforts: Magnetized Target Fusion - Field Reversed Configuration
2006-08-04
interior. 15. SUBJECT TERMS Magnetized Target Fusion (MTF), Field-Reversed Configuration (FRC), Alternative Confinement Concepts, Fusion Energy 16...research, the Department of Energy’s Office of Fusion Energy Studies (DOE OFES). Sections 2 through 4, which follow, describe in detail SAIC’s, FabTek’s...the plasma physics areas (FRCs and fusion energy ) in which we are working. The conference paper was submitted at this time, as well, and will
FE analysis of conceptual hybrid composite endodontic post designs in anterior teeth.
Gloria, Antonio; Maietta, Saverio; Martorelli, Massimo; Lanzotti, Antonio; Watts, David C; Ausiello, Pietro
2018-04-24
To assess conceptual designs of dental posts consisting of polyetherimide (PEI) reinforced with carbon (C) and glass (G) glass fibers in endodontically treated anterior teeth. 3D tessellated CAD and geometric models of endodontically treated anterior teeth were generated from Micro-CT scan images. Model C-G/PEI composite posts with different Young's moduli were analyzed by Finite Element (FE) methods post A (57.7GPa), post B (31.6GPa), post C (from 57.7 to 9.0GPa in the coronal-apical direction). A load of 50N was applied at 45° to the longitudinal axis of the tooth, acting on the palatal surface of the crown. The maximum principal stress distribution was determined along the post and at the interface between the post and the surrounding structure. Post C, with Young's modulus decreasing from 57.7 to 9.0GPa in the coronal-apical direction, reduced the maximum principal stress distribution in the restored tooth. Post C gave reduced stress and the most uniform stress distribution with no stress concentration, compared to the other C-G/PEI composite posts. The FE analysis confirmed the ability of the functionally graded post to dissipate stress from the coronal to the apical end. Hence actual (physical) C-G/PEI posts could permit optimization of stress distributions in endodontically treated anterior teeth. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
Progressive damage, fracture predictions and post mortem correlations for fiber composites
NASA Technical Reports Server (NTRS)
1985-01-01
Lewis Research Center is involved in the development of computational mechanics methods for predicting the structural behavior and response of composite structures. In conjunction with the analytical methods development, experimental programs including post failure examination are conducted to study various factors affecting composite fracture such as laminate thickness effects, ply configuration, and notch sensitivity. Results indicate that the analytical capabilities incorporated in the CODSTRAN computer code are effective in predicting the progressive damage and fracture of composite structures. In addition, the results being generated are establishing a data base which will aid in the characterization of composite fracture.
Brouwer, Marieke T; Thoden van Velzen, Eggo U; Augustinus, Antje; Soethoudt, Han; De Meester, Steven; Ragaert, Kim
2018-01-01
The Dutch post-consumer plastic packaging recycling network has been described in detail (both on the level of packaging types and of materials) from the household potential to the polymeric composition of the recycled milled goods. The compositional analyses of 173 different samples of post-consumer plastic packaging from different locations in the network were combined to indicatively describe the complete network with material flow analysis, data reconciliation techniques and process technological parameters. The derived potential of post-consumer plastic packages in the Netherlands in 2014 amounted to 341 Gg net (or 20.2 kg net.cap -1 .a -1 ). The complete recycling network produced 75.2 Gg milled goods, 28.1 Gg side products and 16.7 Gg process waste. Hence the net recycling chain yield for post-consumer plastic packages equalled 30%. The end-of-life fates for 35 different plastic packaging types were resolved. Additionally, the polymeric compositions of the milled goods and the recovered masses were derived with this model. These compositions were compared with experimentally determined polymeric compositions of recycled milled goods, which confirmed that the model predicts these compositions reasonably well. Also the modelled recovered masses corresponded reasonably well with those measured experimentally. The model clarified the origin of polymeric contaminants in recycled plastics, either sorting faults or packaging components, which gives directions for future improvement measures. Copyright © 2017 Elsevier Ltd. All rights reserved.
Open hole and post-impact compression fatigue of stitched and unstitched carbon/epoxy composites
NASA Technical Reports Server (NTRS)
Portanova, M. A.; Poe, C. C., Jr.; Whitcomb, John D.
1990-01-01
The performance is studied of a stitched uniweave fabric composite and that of a toughened tape composite. The effects of stitching on compression fatigue life are addressed. Post impact compression fatigue and open hole fatigue tests were run on an AS4/3501-6 uniweave with stitching and a toughened IM7/8551-7 tape without stitching. Stitching was found to increase the thickness and consequently the weight of the composite material. The two materials were compared on an equal carbon content basis as well as on an equal weight basis. The excess thickness in the stitched uniweave composite was responsible for the lower fatigue life, on an equal carbon basis, compared to the toughened resin tape composite. Comparison of fatigue lives on an equal carbon content basis indicated that puncture or crimp type damage from stitching has very little effect on compression failure. Post impact fatigue test showed that although the damage area in the stitched uniweave composite was twice that of the toughened tape composite, the fatigue lives of the stitched composite were significantly longer than those of the toughened composite. Thus, it appears that the increase in thickness from stitching is much more of a penalty than crimped fibers or puncture type damage from stitching.
DOT National Transportation Integrated Search
2009-03-01
This project was an implementation of research conducted under TxDOT Research Project 0-4124 on the use : of post-installed shear connectors to develop composite action in existing non-composite steel bridge girder : systems. In this implementation s...
Prehospital Medicine and the Future Will ECMO Ever Play a Role?
Macku, David; Hedvicak, Pavel; Quinn, John; Bencko, Vladimir
Due to the hybrid warfare currently experienced by multiple NATO coalition and NATO partner nations, the tactical combat casualty care (TCCC) paradigm is greatly challenged. One of the major challenges to TCCC is the ad hoc extension phase in resource-poor environments, referred to as prolonged field care (PFC) and forward resuscitative care (FRC). The nuanced clinical skills with limited resources required by warfighters and auxiliary health care professionals to mitigate death on the battlefield and prevent morbidity and mortality in the PFC phase represent a balance that is still under review. The aim of our article is to describe the connection between extracorporeal membrane oxygenation (ECMO) or the extracorporeal life support (ECLS) treatment and its possible improvement in prehospital trauma care, at a Role 1 or 2 facility and, more provocatively, in the PFC phase of care in the future through innovative technology and how it connects with FRC. We report and describe here the primary components of ECMO/ECLS and present the main concept of a human extracorporeal circulation cocoon as a transitional living form for the cardiopulmonary stabilization of wounded combatants on the battlefield and their transportation to higher echelons of care and treatment facilities (to include damage control resuscitation [DCR] and damage control surgery [DCS]). As clinical governance, these matters would fall within the remit of the Committee on Surgical Combat Casualty Care (CoSCCC) and the Committee on Enroute Combat Casualty Care (CoERCCC), and it is within this framework that we propose this concept piece of ECMO in the prehospital space. We caution that this report is a proposed innovation to TCCC but also serves to push the envelope of the PFC and FRC paradigm. What we propose will not change the practice this year, but as ECMO technology progresses, it may change our practice within the next decade. We conclude with proposed novel future research to save life on the battlefield with ECMO as a major challenge and one worth the focus of further research. Medicine is controversial and constantly changing; for those who work in prehospital and battlefield medicine, change is the only constant on which we rely, and without provocative discussion that makes our systems and practice more robust, we will fail. 2018.
Glass Fibre-Reinforced Composite Post and Core Used in Decayed Primary Anterior Teeth: A Case Report
Verma, Leena; Passi, Sidhi
2011-01-01
Aesthetic requirement of severely mutilated primary anterior teeth in the case of early childhood caries has been a challenge to pediatric dentist. Among restorative treatment options, prefabricated crown and biological and resin composite restoration either by means of direct or indirect technique are mentioned in the literature. This paper presents the clinical sequence of rehabilitation of maxillary anterior primary teeth. Endodontic treatment was followed by the placement of a glass fibre-reinforced composite resin post. The crown reconstruction was done with composite restoration. Resin glass fibre post has best properties in elasticity, translucency, adaptability, tenaciousness, and resistance to traction and to impact. Along with ease of application, fiber can be used as an alternative to traditionally used materials in the management of early childhood caries. PMID:22567447
Depth of composite polymerization within simulated root canals using light-transmitting posts.
Lui, J L
1994-01-01
In this study, the depth of cure of composite resins cured within simulated root canals by means of light-transmitting plastic posts was compared to that achieved by the conventional light-curing method. Six sizes of posts with diameters of 1.05 mm, 1.20 mm, 1.35 mm, 1.50 mm, 1.65 mm, and 1.80 mm were investigated. In general, the larger the post diameter, the greater was the depth of cure. There were significant differences in the depth of cure between the control and all sizes of posts investigated. There were also significant differences between the various post diameters except for the 1.35 mm and 1.50 mm diameter posts. It was possible to achieve a depth of cure exceeding 11 mm using these light-transmitting posts.
Engineer’s Handbook. Central Archive for Reusable Defense Software (CARDS)
1994-02-28
benefit frc- this reuse effort? Reuse should be done for a domain rather than just for a program. " Identify relationships between domains to facilitate... benefits to the government and its contractors. " Help provide guidelines to enable domain managers to do a trade-off study on requirements, e.g., does...libraries, if desired or required. This can only occur where the government domain growth matches, or can benefit from, the inclusion or incorporation of the
2009-11-01
quality control RCRA Resource Conservation and Recovery Act SAE Society for Automotive Engineers S-N stress vs number of cycles (fatigue curve...Automotive Engineers ( SAE ) Aerospace Materials Specifications (AMS): Figure 3. Air handler and dust filter installation at FRC-E. 8 - AMS 2447 was...developed with the assistance of the HCAT team and issued by SAE in 1998. It is now a widely used standard in the aerospace industry. - AMS 2448
Annual Report 2015: High Fidelity Modeling of Field-Reversed Configuration (FRC) Thrusters
2016-06-01
simulations become unstable as time evolves leading to the magnetic island collision with the boundary and destruction of the close magnetic field structure...compares well with the results of the Hall-MHD code. 1 R. D. Milroy, "A magnetohydrodynamic model of rotating magnetic field current drive in a field...reversed configuration," Physics of Plasmas, vol. 7, no. 10. 2 Distribution A: Approved for Public Release. PA# 16202 Figure 1. Magnetic field
2015-04-01
to successfully operate after being exposed to the harsh launch vibration environment. 2. Uncover workmanship flaws such as loose fasteners or weak...uncover any workmanship errors in spite of exposing the PPUs to vibration levels in excess of what is expected for flight on any of the launchers ...successfully operate after being exposed to the harsh launch vibration environment. 2. Uncover workmanship flaws such as loose fasteners or weak
Coupled transport in field-reversed configurations
NASA Astrophysics Data System (ADS)
Steinhauer, L. C.; Berk, H. L.; TAE Team
2018-02-01
Coupled transport is the close interconnection between the cross-field and parallel fluxes in different regions due to topological changes in the magnetic field. This occurs because perpendicular transport is necessary for particles or energy to leave closed field-line regions, while parallel transport strongly affects evolution of open field-line regions. In most toroidal confinement systems, the periphery, namely, the portion with open magnetic surfaces, is small in thickness and volume compared to the core plasma, the portion with closed surfaces. In field-reversed configurations (FRCs), the periphery plays an outsized role in overall confinement. This effect is addressed by an FRC-relevant model of coupled particle transport that is well suited for immediate interpretation of experiments. The focus here is particle confinement rather than energy confinement since the two track together in FRCs. The interpretive tool yields both the particle transport rate χn and the end-loss time τǁ. The results indicate that particle confinement depends on both χn across magnetic surfaces throughout the plasma and τǁ along open surfaces and that they provide roughly equal transport barriers, inhibiting particle loss. The interpretation of traditional FRCs shows Bohm-like χn and inertial (free-streaming) τǁ. However, in recent advanced beam-driven FRC experiments, χn approaches the classical rate and τǁ is comparable to classic empty-loss-cone mirrors.
NASA Astrophysics Data System (ADS)
Sawada, Asuka; Hatano, Hironori; Akimitsu, Moe; Cao, Qinghong; Yamasaki, Kotaro; Tanabe, Hiroshi; Ono, Yasushi; TS-Group Team
2017-10-01
We have been investigating 2D potential profile of global merging tokamaks to solve high-power heating of magnetic reconnection in TS-3 and TS-3U (ST, FRC:R =0.2m, 1985-, 2017-) and TS-4 (ST, FRC:R =0.5m, 2000-), UTST (ST:R =0.45m, 2008-) and MAST (ST:R = 0.9m, 2000-) devices. These experiments made clear that the electrostatic potential well is formed not only in the downstream area of magnetic reconnection but also in the whole common (reconnected) flux area of two merging flux tubes: tokamak plasmas. This fact suggests that the ion acceleration/heating occurs in much wider region than the reconnection downstream. We studied how the potential structure depends on key reconnection parameters:guide toroidal field and plasma collisionality. We found the polarity of the guide toroidal field determines those of potential hills and wells, indicating their formation is affected by the Hall effect. The peak value of the electrostatic potential well decreased with gas pressure increasing, suggesting plasma collisionality suppresses the Hall effect. The relationship between the electrostatic potential structure and anomalous ion heating is being studied as a possible cause for the high-power heating of fast magnetic reconnection. This work was supported by JSPS KAKENHI Grant Numbers 15H05750, 15K14279 and 17H04863.
te Pas, Arjan B.; Kitchen, Marcus J.; Lee, Katie; Wallace, Megan J.; Fouras, Andreas; Lewis, Robert A.; Yagi, Naoto; Uesugi, Kentaro; Hooper, Stuart B.
2016-01-01
Background: A sustained inflation (SI) facilitates lung aeration, but the most effective pressure and duration are unknown. We investigated the effect of gestational age (GA) and airway liquid volume on the required inflation pressure and SI duration. Methods: Rabbit kittens were delivered at 27, 29, and 30 d gestation, intubated and airway liquid was aspirated. Either no liquid (control) or 30 ml/kg of liquid was returned to the airways. Lung gas volumes were measured by plethysmography and phase-contrast X-ray-imaging. Starting at 22 cmH2O, airway pressure was increased until airflow commenced and pressure was then held constant. The SI was truncated when 20 ml/kg air had entered the lung and ventilation continued with intermittent positive pressure ventilation (iPPV). Results: Higher SI pressures and longer durations were required in 27-d kittens compared to 30-d kittens. During iPPV, 27-d kittens needed higher pressures and had lower functional residual capacity (FRC) compared to 30-d kittens. Adding lung liquid increased SI duration, reduced FRC, and increased resistance and pressures during iPPV in 29- and 30-d kittens. Conclusion: Immature kittens required higher starting pressures and longer SI durations to achieve a set inflation volume. Larger airway liquid volumes adversely affected lung function during iPPV in older but not young kittens. PMID:26991259
Interaction of Fast Ions with Global Plasma Modes in the C-2 Field Reversed Configuration Experiment
NASA Astrophysics Data System (ADS)
Smirnov, Artem; Dettrick, Sean; Clary, Ryan; Korepanov, Sergey; Thompson, Matthew; Trask, Erik; Tuszewski, Michel
2012-10-01
A high-confinement operating regime [1] with plasma lifetimes significantly exceeding past empirical scaling laws was recently obtained by combining plasma gun edge biasing and tangential Neutral Beam Injection (NBI) in the C-2 field-reversed configuration (FRC) experiment [2, 3]. We present experimental and computational results on the interaction of fast ions with the n=2 rotational and n=1 wobble modes in the C-2 FRC. It is found that the n=2 mode is similar to quadrupole magnetic fields in its detrimental effect on the fast ion transport due to symmetry breaking. The plasma gun generates an inward radial electric field, thus stabilizing the n=2 rotational instability without applying the quadrupole magnetic fields. The resultant FRCs are nearly axisymmetric, which enables fast ion confinement. The NBI further suppresses the n=2 mode, improves the plasma confinement characteristics, and increases the plasma configuration lifetime [4]. The n=1 wobble mode has relatively little effect on the fast ion transport, likely due to the approximate axisymmetry about the displaced plasma column. [4pt] [1] M. Tuszewski et al., Phys. Rev. Lett. 108, 255008 (2012).[0pt] [2] M. Binderbauer et al., Phys. Rev. Lett. 105, 045003 (2010).[0pt] [3] H.Y. Guo et al., Phys. Plasmas 18, 056110 (2011).[0pt] [4] M. Tuszewski et al., Phys. Plasmas 19, 056108 (2012)
Multiple breath washout analysis in infants: quality assessment and recommendations for improvement.
Anagnostopoulou, Pinelopi; Egger, Barbara; Lurà, Marco; Usemann, Jakob; Schmidt, Anne; Gorlanova, Olga; Korten, Insa; Roos, Markus; Frey, Urs; Latzin, Philipp
2016-03-01
Infant multiple breath washout (MBW) testing serves as a primary outcome in clinical studies. However, it is still unknown whether current software algorithms allow between-centre comparisons. In this study of healthy infants, we quantified MBW measurement errors and tried to improve data quality by simply changing software settings. We analyzed best quality MBW measurements performed with an ultrasonic flowmeter in 24 infants from two centres in Switzerland with the current software settings. To challenge the robustness of these settings, we also used alternative analysis approaches. Using the current analysis software, the coefficient of variation (CV) for functional residual capacity (FRC) differed significantly between centres (mean ± SD (%): 9.8 ± 5.6 and 5.8 ± 2.9, respectively, p = 0.039). In addition, FRC values calculated during the washout differed between -25 and +30% from those of the washin of the same tracing. Results were mainly influenced by analysis settings and temperature recordings. Changing few algorithms resulted in significantly more robust analysis. Non-systematic inter-centre differences can be reduced by using correctly recorded environmental data and simple changes in the software algorithms. We provide implications that greatly improve infant MBW outcomes' quality and can be applied when multicentre trials are conducted.
Gounga, M E; Xu, S-Y; Wang, Z; Yang, W G
2008-05-01
Harvested chestnut is characterized by a short shelf life, exposing many Chinese producers to a storage problem as product losses are very high. The objective of this study was to develop a suitable technology to extend the shelf life of harvested chestnut fruits for commercial use. The effect of whey protein isolate-pullulan (WPI-Pul) coating on fresh-roasted chestnuts (FRC) and roasted freeze-dried chestnut (RFDC) quality and shelf life was studied under 2 different storage temperature (4 and 20 degrees C) conditions. Coatings were formed directly onto the surface of the fruits by dipping them into a film solution. SEM micrographs showed homogeneous WPI-Pul to cover the whole surface of chestnut with good adherence and perfect integrity. Moisture loss or gain, fruit quality, and shelf life were evaluated by weight loss or gain, surface color development, and visible decay during the storage period of 15 to 120 d at 4 and 20 degrees C, respectively. WPI-Pul coating had a low, yet significant effect on reducing moisture loss and decay incidence of FRC, hence delaying changes in their external color. The results were satisfactory when the coating was done with freeze-drying at low temperature storage, thus improving the quality and increasing the shelf life. This provides an alternative strategy to minimize the significant losses in harvested chestnut.
Growth, body composition, and bone density following pediatric liver transplantation.
Sheikh, Amin; Cundy, Tim; Evans, Helen Maria
2018-04-24
Patients transplanted for cholestatic liver disease are often significantly fat-soluble vitamin deficient and malnourished pretransplant, with significant corticosteroid exposure post-transplant, with increasing evidence of obesity and metabolic syndrome post-LT. Our study aimed to assess growth, body composition, and BMD in patients post-pediatric LT. Body composition and bone densitometry scans were performed on 21 patients. Pre- and post-transplant anthropometric data were analyzed. Bone health was assessed using serum ALP, calcium, phosphate, and procollagen-1-N-peptide levels. Median ages at transplant and at this assessment were 2.7 and 10.6 years, respectively. Physiological markers of bone health, median z-scores for total body, and lumbar spine aBMD were normal. Bone area was normal for height and BMAD at L3 was normal for age, indicating, respectively, normal cortical and trabecular bone accrual. Median z-scores for weight, height, and BMI were 0.6, -0.9, 1.8 and 0.6, 0.1, 0.8 pre- and post-transplant, respectively. Total body fat percentages measured on 21 body composition scans revealed 2 underweight, 7 normal, 6 overweight, and 6 obese. Bone mass is preserved following pediatric LT with good catch-up height. About 52% of patients were either overweight/obese post-transplant, potentially placing them at an increased risk of metabolic syndrome and its sequelae in later life. BMI alone is a poor indicator of nutritional status post-transplant. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Buckling and Post-Buckling Behaviors of a Variable Stiffness Composite Laminated Wing Box Structure
NASA Astrophysics Data System (ADS)
Wang, Peiyan; Huang, Xinting; Wang, Zhongnan; Geng, Xiaoliang; Wang, Yuansheng
2018-04-01
The buckling and post-buckling behaviors of variable stiffness composite laminates (VSCL) with curvilinear fibers were investigated and compared with constant stiffness composite laminates (CSCL) with straight fibers. A VSCL box structure was evaluated under a pure bending moment. The results of the comparative test showed that the critical buckling load of the VSCL box was approximately 3% higher than that of the CSCL box. However, the post-buckling load-bearing capacity was similar due to the layup angle and the immature status of the material processing technology. The properties of the VSCL and CSCL boxes under a pure bending moment were simulated using the Hashin criterion and cohesive interface elements. The simulation results are consistent with the experimental results in stiffness, critical buckling load and failure modes but not in post-buckling load capacity. The results of the experiment, the simulation and laminated plate theory show that VSCL greatly improves the critical buckling load but has little influence on the post-buckling load-bearing capacity.
Almaroof, A; Rojo, L; Mannocci, F; Deb, S
2016-02-01
To formulate and evaluate new dual cured resin composite based on the inclusion of eugenyl methacrylate monomer (EgMA) with Bis-GMA/TEGDMA resin systems for intracanal post cementation and core build-up restoration of endodontically treated teeth. EgMA was synthesized and incorporated at 5% (BTEg5) or 10% (BTEg10) into dual-cure formulations. Curing properties, viscosity, Tg, radiopacity, static and dynamic mechanical properties of the composites were determined and compared with Clearfil™DC Core-Plus, a commercial dual-cure, two-component composite. Statistical analysis of the data was performed with ANOVA and the Tukey's post-hoc test. The experimental composites were successfully prepared, which exhibited excellent curing depths of 4.9, 4.7 and 4.2 mm for BTEg0, BTEg5 and BTEg10 respectively, which were significantly higher than Clearfil™DC. However, the inclusion of EgMA initially led to a lower degree of cure, which increased when measured at 24 h with values comparable to formulations without EgMA, indicating post-curing. The inclusion of EgMA also lowered the polymerization exotherm thereby reducing the potential of thermal damage to host tissue. Both thermal and viscoelastic analyses confirmed the ability of the monomer to reduce the stiffness of the composites by forming a branched network. The compressive strength of BTEg5 was significantly higher than the control whilst flexural strength increased significantly from 95.9 to 114.8 MPa (BTEg5) and 121.9 MPa (BTEg10). Radiopacity of the composites was equivalent to ∼3 mm Al allowing efficient diagnosis. The incorporation of EgMA within polymerizable formulations provides a novel approach to prepare reinforced resin composite material for intracanal post cementation and core build-up and the potential to impart antibacterial properties of eugenol to endodontic restorations. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Minett, M M; Binkley, T B; Weidauer, L A; Specker, B L
2017-03-01
To assess body composition and bone changes pre- to post-season (pre-post) and post- to off-season (post-off) in female soccer athletes (SC). Outcomes were assessed using DXA and pQCT in 23 SC and 17 controls at three times throughout season. SC, non-starters in particular, lost lean mass pre-post (-0.9±0.2 kg, p<0.01; not different from controls, p=0.2) and gained fat mass post-off (1.4±0.3 kg, p<0.01; differed from controls, p=0.01). Baseline femoral neck and hip aBMD were higher in SC than controls (both,p<0.04), but increased in controls more than SC in pre-post and decreased post-off. SC cortical bone mineral content (BMC), cortical area and periosteal circumference increased pre-post (all, p<0.01; differed from controls, p<0.05) and trabecular vBMD decreased post-off (-3.0±1.3 mg/cm 3 ; p=0.02; not different from controls, p=0.4). Both SC and controls increased cortical BMC, cortical area, and thickness post-off (all, p<0.01). Soccer players lost lean mass over the competitive season that was not recovered during off-season. Bone size increased pre- to post-season. Female soccer athletes experience body composition and bone geometry changes that differ depending on the time of season and on athlete's playing status. Evaluations of athletes at key times across the training season are necessary to understand changes that occur.
Effect of restoration technique on stress distribution in roots with flared canals: an FEA study.
Belli, Sema; Eraslan, Öznur; Eraslan, Oğuz; Eskitaşcıoğlu, Gürcan
2014-04-01
The aim of this finite element analysis (FEA) study was to test the effect of different restorative techniques on stress distribution in roots with flared canals. Five three-dimensional (3D) FEA models that simulated a maxillary incisor with excessive structure loss and flared root canals were created and restored with the following techniques/materials: 1) a prefabricated post: 2) one main and two accessory posts; 3) i-TFC post-core (Sun Medical); 4) the thickness of the root was increased by using composite resin and the root was then restored using a prefabricated post; 5) an anatomic post was created by using composite resin and a prefabricated glass-fiber post. Composite cores and ceramic crowns were created. A 300-N static load was applied at the center of the palatal surface of the tooth to calculate stress distributions. SolidWorks/Cosmosworks structural analysis programs were used for FEA analysis. The analysis of the von Mises and tensile stress values revealed that prefabricated post, accessory post, and i-TFC post systems showed similar stress distributions. They all showed high stress areas at the buccal side of the root (3.67 MPa) and in the cervical region of the root (> 3.67 MPa) as well as low stress accumulation within the post space (0 to 1 MPa). The anatomic post kept the stress within its body and directed less stress towards the remaining tooth structure. The creation of an anatomic post may save the remaining tooth structure in roots with flared canals by reducing the stress levels.
Minett, M.M.; Binkley, T.B.; Weidauer, L.A.; Specker, B.L.
2017-01-01
Objectives: To assess body composition and bone changes pre- to post-season (pre-post) and post- to off-season (post-off) in female soccer athletes (SC). Methods: Outcomes were assessed using DXA and pQCT in 23 SC and 17 controls at three times throughout season. Results: SC, non-starters in particular, lost lean mass pre-post (-0.9±0.2 kg, p<0.01; not different from controls, p=0.2) and gained fat mass post-off (1.4±0.3 kg, p<0.01; differed from controls, p=0.01). Baseline femoral neck and hip aBMD were higher in SC than controls (both, p<0.04), but increased in controls more than SC in pre-post and decreased post-off. SC cortical bone mineral content (BMC), cortical area and periosteal circumference increased pre-post (all, p<0.01; differed from controls, p<0.05) and trabecular vBMD decreased post-off (-3.0±1.3 mg/cm3; p=0.02; not different from controls, p=0.4). Both SC and controls increased cortical BMC, cortical area, and thickness post-off (all, p<0.01). Conclusion: Soccer players lost lean mass over the competitive season that was not recovered during off-season. Bone size increased pre- to post-season. Female soccer athletes experience body composition and bone geometry changes that differ depending on the time of season and on athlete’s playing status. Evaluations of athletes at key times across the training season are necessary to understand changes that occur. PMID:28250243
Post-Buckling and Ultimate Strength Analysis of Stiffened Composite Panel Base on Progressive Damage
NASA Astrophysics Data System (ADS)
Zhang, Guofan; Sun, Xiasheng; Sun, Zhonglei
Stiffened composite panel is the typical thin wall structure applied in aerospace industry, and its main failure mode is buckling subjected to compressive loading. In this paper, the development of an analysis approach using Finite Element Method on post-buckling behavior of stiffened composite structures under compression was presented. Then, the numerical results of stiffened panel are obtained by FE simulations. A thorough comparison were accomplished by comparing the load carrying capacity and key position strains of the specimen with test. The comparison indicates that the FEM results which adopted developed methodology could meet the demand of engineering application in predicting the post-buckling behavior of intact stiffened structures in aircraft design stage.
Neutral Entrainment Demonstration in a Xenon FRC Thruster Experiment
2013-03-01
eee e E E ione e thermalionk k Total K 2 2 1 2 1 2 0 2 0 Electric Propulsion on Light Gases Real plasma-based propulsion systems take...kNECEELFkthermalion kNECEELFk PPUT Neeee Nee ELFkELFkFF NEkELFk PPU KFF K PPUT NEEE NEE EE E
Tearing relaxation and the globalization of transport in field-reversed configurations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinhauer, Loren; Barnes, D. C.
2009-09-15
Tearing instability of field-reversed configurations (FRC) is investigated using the method of neighboring equilibria. It is shown that the conducting wall position in experiment lies very close to the location needed for tearing stability. This strongly suggests that vigorous but benign tearing modes, acting globally, are the engine of continual self-organization in FRCs, i.e., tearing relaxation. It also explains the ''profile consistency'' and anomalous loss rate of magnetic flux. In effect, tearing globalizes the effect of edge-driven transport.
1990-05-01
ALARM LAMPS A CHECK TWT POWER SUPPLY VOLTAGE AND CURRENT A ADJUST POWER ALARM THRESHOLD AND TRANSMITTER OUTPUT A CHECK HELIX MONITOR K INTERPRET AN/FRC...POWER SUPPLY A CHECK TRAVELING WAVE TUBE ( TWT ) POWER SUPPLY HELIX CURRENT AND BEAM CURRENT A CHECK TWT RF POWER OUTPUT A CHECK TRANSMITTER POWER...A ADJUST TRANSMITTER LINEARITY A CALIBRATE TRANSMIT DEVIATION AND ADJUST MODULATION AMPLIFIER A ADJUST TWT PERFORMANCE MONITOR A ADJUST TWT OUTPUT
1983-12-01
58 APPENDIX B: COVER LEITERS RxErV FRC4 LABOR AND SHIPPING ORGANIZATINS ................................ 70 LIST CF...result of a merger between the Coast Seamen’ s Union and the Pacific Steamship Sailors’ Union. The SUP was under the leadership of Mr. Andrew Furuseth... leadership to emerge on the West Coast. As this emerging leadership tried to make new gains on the East Coast, it began to cme in conflict with the old-line
1987-12-01
Ffld. I-r &I6a ac rXpE~cjAi.Ly Pf~cgEt CiefkBIE bWb&S P-e1* I(j01Wjt SlAUEi. £jtFrc/gPAEA TAE -e.. &~C P.coy MSfi/.Cr ST~ftvh1 C0R* lID~ lA RuDf AS*fb...severe property and economia losses and a potential for environmental Impacts which could be substantially worse than the temporary Impaot to the
Effects of metal- and fiber-reinforced composite root canal posts on flexural properties.
Kim, Su-Hyeon; Oh, Tack-Oon; Kim, Ju-Young; Park, Chun-Woong; Baek, Seung-Ho; Park, Eun-Seok
2016-01-01
The aim of this study was to observe the effects of different test conditions on the flexural properties of root canal post. Metal- and fiber-reinforced composite root canal posts of various diameters were measured to determine flexural properties using a threepoint bending test at different conditions. In this study, the span length/post diameter ratio of root canal posts varied from 3.0 to 10.0. Multiple regression models for maximum load as a dependent variable were statistically significant. The models for flexural properties as dependent variables were statistically significant, but linear regression models could not be fitted to data sets. At a low span length/post diameter ratio, the flexural properties were distorted by occurrence of shear stress in short samples. It was impossible to obtain high span length/post diameter ratio with root canal posts. The addition of parameters or coefficients is necessary to appropriately represent the flexural properties of root canal posts.
Cu isotopic signature in blood serum of liver transplant patients: a follow-up study
NASA Astrophysics Data System (ADS)
Lauwens, Sara; Costas-Rodríguez, Marta; van Vlierberghe, Hans; Vanhaecke, Frank
2016-07-01
End-stage liver disease (ESLD) is life-threatening and liver transplantation (LTx) is the definitive treatment with good outcomes. Given the essential role of hepatocytes in Cu homeostasis, the potential of the serum Cu isotopic composition for monitoring a patient’s condition post-LTx was evaluated. For this purpose, high-precision Cu isotopic analysis of blood serum of ESLD patients pre- and post-LTx was accomplished via multi-collector ICP-mass spectrometry (MC-ICP-MS). The Cu isotopic composition of the ESLD patients was fractionated in favour of the lighter isotope (by about -0.50‰). Post-LTx, a generalized normalization of the Cu isotopic composition was observed for the patients with normal liver function, while it remained light when this condition was not reached. A strong decrease in the δ65Cu value a longer term post-LTx seems to indicate the recurrence of liver failure or cancer. The observed trend in favour of the heavier Cu isotopic composition post-LTx seems to be related with the restored biosynthetic capacity of the liver, the restored hepatic metabolism and/or the restored biliary secretion pathways. Thus, Cu isotopic analysis could be a valuable tool for the follow-up of liver transplant patients and for establishing the potential recurrence of liver failure.
Cu isotopic signature in blood serum of liver transplant patients: a follow-up study
Lauwens, Sara; Costas-Rodríguez, Marta; Van Vlierberghe, Hans; Vanhaecke, Frank
2016-01-01
End-stage liver disease (ESLD) is life-threatening and liver transplantation (LTx) is the definitive treatment with good outcomes. Given the essential role of hepatocytes in Cu homeostasis, the potential of the serum Cu isotopic composition for monitoring a patient’s condition post-LTx was evaluated. For this purpose, high-precision Cu isotopic analysis of blood serum of ESLD patients pre- and post-LTx was accomplished via multi-collector ICP-mass spectrometry (MC-ICP-MS). The Cu isotopic composition of the ESLD patients was fractionated in favour of the lighter isotope (by about −0.50‰). Post-LTx, a generalized normalization of the Cu isotopic composition was observed for the patients with normal liver function, while it remained light when this condition was not reached. A strong decrease in the δ65Cu value a longer term post-LTx seems to indicate the recurrence of liver failure or cancer. The observed trend in favour of the heavier Cu isotopic composition post-LTx seems to be related with the restored biosynthetic capacity of the liver, the restored hepatic metabolism and/or the restored biliary secretion pathways. Thus, Cu isotopic analysis could be a valuable tool for the follow-up of liver transplant patients and for establishing the potential recurrence of liver failure. PMID:27468898
Cu isotopic signature in blood serum of liver transplant patients: a follow-up study.
Lauwens, Sara; Costas-Rodríguez, Marta; Van Vlierberghe, Hans; Vanhaecke, Frank
2016-07-29
End-stage liver disease (ESLD) is life-threatening and liver transplantation (LTx) is the definitive treatment with good outcomes. Given the essential role of hepatocytes in Cu homeostasis, the potential of the serum Cu isotopic composition for monitoring a patient's condition post-LTx was evaluated. For this purpose, high-precision Cu isotopic analysis of blood serum of ESLD patients pre- and post-LTx was accomplished via multi-collector ICP-mass spectrometry (MC-ICP-MS). The Cu isotopic composition of the ESLD patients was fractionated in favour of the lighter isotope (by about -0.50‰). Post-LTx, a generalized normalization of the Cu isotopic composition was observed for the patients with normal liver function, while it remained light when this condition was not reached. A strong decrease in the δ(65)Cu value a longer term post-LTx seems to indicate the recurrence of liver failure or cancer. The observed trend in favour of the heavier Cu isotopic composition post-LTx seems to be related with the restored biosynthetic capacity of the liver, the restored hepatic metabolism and/or the restored biliary secretion pathways. Thus, Cu isotopic analysis could be a valuable tool for the follow-up of liver transplant patients and for establishing the potential recurrence of liver failure.
Experimental Nonlinear Dynamics and Snap-Through of Post-Buckled Thin Laminated Composite Plates
NASA Astrophysics Data System (ADS)
Kim, Han-Gyu
Modern aerospace systems are increasingly being designed with composite panels and plates to achieve light weight and high specific strength and stiffness. For constrained panels, thermally-induced axial loading may cause buckling of the structure, which can lead to nonlinear and potentially chaotic behavior. When post-buckled composite plates experience snap-through, they are subjected to large-amplitude deformations and in-plane compressive loading. These phenomena pose a potential threat to the structural integrity of composite structures. In this work, the nonlinear dynamic behavior of post-buckled composite plates was investigated experimentally and computationally. For the experimental work, an electrodynamic shaker was used to apply harmonic loads and the dynamic response of plate specimens was measured using a single-point displacement-sensing laser, a double-point laser vibrometer (velocity-sensing), and a set of digital image correlation cameras. Both chaotic and periodic steady-state snap-through behaviors were investigated. The experimental data were used to characterize snap-through behaviors of the post-buckled specimens and their boundaries in the harmonic forcing parameter space. The nonlinear behavior of post-buckled plates was modeled using the classical laminated plate theory (CLPT) and the von Karman strain-displacement relations. The static equilibrium paths of the post-buckled plates were analyzed using an arc-length method with a branch-switching technique. For the dynamic analysis, the nonlinear equations of motion were derived based on CLPT and the nonlinear finite element model of the equations was constructed using the Hermite cubic interpolation functions for both conforming and nonconforming elements. The numerical analyses were conducted using the model and were compared with the experimental data.
Carbon fiber reinforced root canal posts. Mechanical and cytotoxic properties.
Torbjörner, A; Karlsson, S; Syverud, M; Hensten-Pettersen, A
1996-01-01
The aim of this study was to compare the mechanical properties of a prefabricated root canal post made of carbon fiber reinforced composites (CFRC) with metal posts and to assess the cytotoxic effects elicited. Flexural modulus and ultimate flexural strength was determined by 3 point loading after CRFC posts had been stored either dry or in water. The bending test was carried out with and without preceding thermocycling of the CFRC posts. The cytotoxicity was evaluated by an agar overlay method after dry and wet storage. The values of flexural modulus and ultimate flexural strength were for dry stored CFRC post 82 +/- 6 GPa and 1154 +/- 65 MPa respectively. The flexural values decreased significantly after water storage and after thermocycling. No cytotoxic effects were observed adjacent to any CFRC post. Although fiber reinforced composites may have the potential to replace metals in many clinical situations, additional research is needed to ensure a satisfying life-span.
Fabricating fiber-reinforced composite posts.
Manhart, Jürgen
2011-03-01
Endodontic posts do not increase the strength of the remaining tooth structure in endodontically treated teeth. On the contrary, depending on the post design employed (tapered versus parallel-sided), the root can be weakened relative to the amount of tooth removed during preparation. In many cases, if there has been a high degree of damage to the clinical crown, conservative preparation for an anatomic tapered (biomimetic) post with the incorporation of a ferrule on solid tooth structure is necessary to protect the reaming root structure as well as for the long-term retention of the composite resin core and the definitive restoration. Adhesively luted endodontic posts reinforced with glass or quartz fiber lead to better homogeneous tension distribution when loaded than rigid metal or zirconium oxide ceramic posts. Fiber-reinforced posts also possess advantageous optical properties over metal or metal oxide post systems. The clinician should realize that there are admittedly substantial differences in the mechanical loading capacity of the different fiber-reinforced endodontic posts and should be aware of such differences in order to research and select a suitable post system for use.
Samadi, Firoza; Jaiswal, JN; Saha, Sonali
2014-01-01
ABSTRACT% Aim: To compare the effect of different chemical solvents on glass fiber reinforced posts and to study the effect of these solvents on the shear bond strength of glass fiber reinforced post to core material. Materials and methods: This study was conducted to evaluate the effect of three chemical solvents, i.e. silane coupling agent, 6% H2O2 and 37% phosphoric acid on the shear bond strength of glass fiber post to a composite resin restorative material. The changes in post surface characteristics after different treatments were also observed, using scanning electron microscopy (SEM) and shear bond strength was analyzed using universal testing machine (UTM). Results: Surface treatment with hydrogen peroxide had greatest impact on the post surface followed by 37% phosphoric acid and silane. On evaluation of the shear bond strength, 6% H2O2 exhibited the maximum shear bond strength followed in descending order by 37% phosphoric acid and silane respectively. Conclusion: The surface treatment of glass fiber post enhances the adhesion between the post and composite resin which is used as core material. Failure of a fiber post and composite resin core often occurs at the junction between the two materials. This failure process requires better characterization. How to cite this article: Sharma A, Samadi F, Jaiswal JN, Saha S. A Comparative Evaluation of Effect of Different Chemical Solvents on the Shear Bond Strength of Glass Fiber Reinforced Post to Core Material. Int J Clin Pediatr Dent 2014;7(3):192-196. PMID:25709300
Effect of CNT addition on cure kinetics of glass fiber/epoxy composite
NASA Astrophysics Data System (ADS)
Fulmali, A. O.; Kattaguri, R.; Mahato, K. K.; Prusty, R. K.; Ray, B. C.
2018-03-01
In present time, developments in reinforced polymer composites have acquired preferential attention for high performance and high precision applications like aerospace, marine and transportation. Fibre reinforced polymer (FRP) composites are being substituted because of their low density, higher strength, stiffness, impact resistance, and improved corrosion resistance. Further laminated composites exhibit superior in-plane mechanical properties that are mostly governed by the fibers. However, laminated FRP composites suffer from poor out of plane properties in some applications. These properties can further be improved by the addition of Nano fillers like carbon nanotube (CNT), graphene and so on. Curing cycle plays a very important role in drawing out the optimum property of glass fiber/epoxy (GE) composite. It is expected that the cure kinetics can further be altered by addition of CNT due to its higher aspect ratio. The main objective of this work is to study the effect of CNT addition on cure kinetics of GE composite as multi-segment adsorption of polymer takes place on the CNT surface. In this study effects of curing parameters on mechanical properties and glass transition temperature of CNT embedded glass fiber/epoxy composite (CNT-GE) has been evaluated. For this study control GE and CNT-GE (with 0.1 wt. %) laminates were fabricated using hand lay-up technique followed by hot compression. The curing parameters that were considered in the present investigation were temperature (80°C, 110°C, and 140°C) and time (0.5 hr, 3 hr and 6 hr). For different combination of above mentioned temperature and time, samples of GE and CNT-GE composites were post cured. Mechanical properties were determined by flexural testing using 3 point bending fixture on INSTRON-5967 and thermal properties i.e. glass transition temperature (Tg) determined by Differential Scanning Calorimeter (DSC) to evaluate the effects of curing parameters. For CNT-GE samples, No much variation observed in flexural modulus with increase in post curing temperature and time, but swift increment was observed in flexural strength at 140°C with increase in post cure time. Elevation in Tg observed with increase in temperature and time duration of post curing; highest Tg noted at 140°C-6hr. Optimum post curing parameters for CNT-GE composite observed to be 140°C-6hr.
Local Volume Hi Survey: the far-infrared radio correlation
NASA Astrophysics Data System (ADS)
Shao, Li; Koribalski, Bärbel S.; Wang, Jing; Ho, Luis C.; Staveley-Smith, Lister
2018-06-01
In this paper we measure the far-infrared (FIR) and radio flux densities of a sample of 82 local gas-rich galaxies, including 70 "dwarf" galaxies (M* < 109 M⊙), from the Local Volume HI Survey (LVHIS), which is close to volume limited. It is found that LVHIS galaxies hold a tight linear FIR-radio correlation (FRC) over four orders of magnitude (F_1.4GHz ∝ F_FIR^{1.00± 0.08}). However, for detected galaxies only, a trend of larger FIR-to-radio ratio with decreasing flux density is observed. We estimate the star formation rate by combining UV and mid-IR data using empirical calibration. It is confirmed that both FIR and radio emission are strongly connected with star formation but with significant non-linearity. Dwarf galaxies are found radiation deficient in both bands, when normalized by star formation rate. It urges a "conspiracy" to keep the FIR-to-radio ratio generally constant. By using partial correlation coefficient in Pearson definition, we identify the key galaxy properties associated with the FIR and radio deficiency. Some major factors, such as stellar mass surface density, will cancel out when taking the ratio between FIR and radio fluxes. The remaining factors, such as HI-to-stellar mass ratio and galaxy size, are expected to cancel each other due to the distribution of galaxies in the parameter space. Such cancellation is probably responsible for the "conspiracy" to keep the FRC alive.
NASA Astrophysics Data System (ADS)
Birdsall, Charles K.
1986-12-01
The Pierce diode linear behavior with external R, C, or L was verified very accurately by particle simulation. The Pierce diode non-linear equilibria with R, C, or L are described theoretically and explored via computer simulation. A simple model of the sheath outside the separatrix of an FRC was modeled electrostatically in 2d and large potentials due to the magnetic well and peak which were found. These may explain the anomalously high ion confinement in the FRC edge layer. A planar plasma source with cold ions and warm electrons produces a source sheath with sufficient potential drop to accelerate ions to sound velocity, which obviates the need for a Bohm pre-collector-sheath electric field. Final reports were prepared for collector sheath, presheath, and source sheath in a collisionless, finite ion temperature plasma; potential drop and transport in a bounded plasma with ion reflection at the collector; potential drop and transport in a bounded plasma with secondary electron emission at the collector. A movie has been made displaying the long-lived vortices resulting from the Kelvin-Helmholtz instability in a magnetized sheath. A relativistic Monte Carlo binary (Coulomb) collision model has been developed and tested for inclusion into the electrostatic particle simulation code TESS. Two direct implicit time integration schemes are tested for self-heating and self-cooling and regions of neither are found as a function of delta t and delta x for the model of a freely expanding plasma slab.
NASA Astrophysics Data System (ADS)
Akimitsu, Moe; Qinghong, Cao; Sawada, Asuka; Hatano, Hironori; Tanabe, Hiroshi; Ono, Yasushi; TS-Group Team
2017-10-01
We have developed a new-types of high-resolution magnetic probe array for our new magnetic reconnection experiments: TS-3U (ST, FRC: R =0.2m, 2017-) and TS-4U (ST, FRC: R =0.5m, 2018-), using the advanced printed-circuit technology. They are equipped with all three-components of magnetic pick-up coils whose size is 1-5mm x 3mm. Each coil is composed of two-sided coil pattern with line width of 0.05mm. We can install two or three printed arrays in a single glass (ceramic) tube for two or three component measurements. Based on this new probe technique, we started high-resolution and high-accuracy measurement of the current sheet thickness and studied its plasma parameter dependence. We found that the thickness of current sheet increases inversely with the guide toroidal field. It is probably determined by the ion gyroradius in agreement with the particle simulation by Horiuchi etc. While the reconnection speed is steady under low guide field condition, it is observed to oscillate in the specific range of guide field, suggesting transition from the quasi-steady reconnection to the intermittent reconnection. Cause and mechanism for intermittent reconnection will be discussed using the current sheet dissipation and dynamic balance between plasma inflow and outflow. This work supported by JSPS KAKENHI Grant Numbers 15H05750, 15K14279 and 17H04863.
Respiratory function in pregnancy at sea level and at high altitude.
McAuliffe, Fionnuala; Kametas, Nikos; Espinoza, Jimmy; Greenough, Anne; Nicolaides, Kypros
2004-04-01
To determine the effect of pregnancy on respiratory function in a non-Caucasian group and determine whether there was an interaction between pregnancy and altitude of residence. Prospective cross sectional study. Antenatal clinics in Peru, at sea level in Lima and at high altitude in Cerro de Pasco. Peruvian women with singleton pregnancies; 122 living at sea level and 192 living at 4300 m altitude in the Peruvian Andes. At each location, 19 non-pregnant women were also studied. Respiratory function was measured in pregnant and non-pregnant women living at sea level and at 4300 m. Forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), peak expiratory flow rate (PEFR), total lung capacity (TLC), inspiratory capacity (IC), residual volume (RV), expiratory residual volume (ERV) and functional residual capacity (FRC). At sea level, RV and TLC were higher in the third compared with the first trimester (P < 0.05). At high altitude, FEV1 (P < 0.01), ERV (P < 0.01) and FRC (P < 0.01) were lower in the third compared with the first trimester. Pregnant and non-pregnant women at high altitude were 4 cm shorter (P < 0.0001) and had larger lung volumes (P < 0.01); their total lung capacities were approximately 1 L greater than women living at sea level (P < 0.0001). These results suggest that the effect of pregnancy on the respiratory function of healthy women is influenced by altitude of residence.
Long-term effects of clearcutting on tree species composition in an oak-hickory forest
Jessica A. Yeagle; John W. Groninger
2006-01-01
In 1973, a silvicultural clearcut, with and without a post-harvest herbicide treatment, was performed on an upland oak-hickory forest in southern Illinois. Prior to harvest, permanent plots were established, and a survey was conducted to determine stand structure and composition. In 2003, a post-harvest survey was performed using the permanent plots. Relative density...
High Theory, the Teaching of Writing, and the Crisis of the University
ERIC Educational Resources Information Center
Pawlowski, Lucia
2012-01-01
Post-structuralism, a theory of signs for written texts, would seem an obvious resource for a field like Composition Studies that has "writing" at its center. Yet the post-structuralist turn in Composition Studies is hamstrung by the deep division between camps in the field that are committed to political critique on the one hand or to…
Effects of a sustained inflation in preterm infants at birth.
van Vonderen, Jeroen J; Hooper, Stuart B; Hummler, Helmut D; Lopriore, Enrico; te Pas, Arjan B
2014-11-01
To assess the clinical effect of an initial sustained inflation of 10 seconds and 25 cmH2O in preterm infants at birth. In this observational study inflation pressures and tidal volumes were recorded with the use of respiratory function monitoring of preterm infants <32 weeks' gestation receiving a sustained inflation. Inspiratory tidal volume (Vti) and expiratory tidal volume (Vte) of sustained inflation and cumulative Vti and Vte of breaths during sustained inflation were determined. Heart rate and oxygen saturation were measured before and after the sustained inflation. Seventy infants were included (median [IQR]: gestational age 29 [27-30] weeks). Mean (SD) sustained inflation duration was 10.5 seconds (2.9 seconds) with positive inflation pressure 24.2 cmH2O (2.3 cmH2O) and positive end-expiratory pressure 6.0 cmH2O (1.8 cmH2O). In 20 of 70 infants, no volumes were delivered during the sustained inflation because of mask leak. No leak occurred in 50 of 70 infants, of whom 36 of 50 breathed during the sustained inflation. In 14 of the infants who did not breathe, Vti and Vte were 0.9 mL/kg (0.4-2.7 mL/kg) and 0.6 mL/kg (0.1-2.0 mL/kg) with a functional residual capacity (FRC) gain of 0.0 (-0.5 to 0.6) mL/kg. In 36 of 50 infants who breathed during the sustained inflation, Vti was 2.9 mL/kg (0.9-9.2 mL/kg) and Vte 3.8 mL/kg (1.0-5.9 mL/kg), whereas cumulative Vti of breaths was 16.4 mL/kg (6.8-23.3 mL/kg) and cumulative Vte of breaths was 5.8 mL/kg (1.2-16.8 mL/kg) with an FRC gain of 7.1 mL/kg (1.7-15.9 mL/kg). Heart rate and oxygen saturation did not increase immediately after the sustained inflation. A sustained inflation of 10 seconds and 25 cmH2O in preterm infants at birth was not effective unless infants breathed. Although large mask leak accounted for approximately one-third of failures, as FRC gain was only associated with breathing, we speculate that active glottic adduction may be responsible for most failures. Copyright © 2014 Elsevier Inc. All rights reserved.
Raygot, C G; Chai, J; Jameson, D L
2001-01-01
This study was undertaken to characterize the fracture resistance and mode of fracture of endodontically treated incisors restored with cast post-and-core, prefabricated stainless steel post, or carbon fiber-reinforced composite post systems. Ten endodontically treated teeth restored with each technique were subjected to a compressive load delivered at a 130-degree angle to the long axis until the first sign of failure was noted. The fracture load and the mode of fracture were recorded. The failure loads registered in the three groups were not significantly different. Between 70%, and 80% of teeth from any of the three groups displayed fractures that were located above the simulated bone level. The use of carbon fiber-reinforced composite posts did not change the fracture resistance or the failure mode of endodontically treated central incisors compared to the use of metallic posts.
Characterisation of the metabolome of ocular tissues and post-mortem changes in the rat retina.
Tan, Shi Z; Mullard, Graham; Hollywood, Katherine A; Dunn, Warwick B; Bishop, Paul N
2016-08-01
Time-dependent post-mortem biochemical changes have been demonstrated in donor cornea and vitreous, but there have been no published studies to date that objectively measure post-mortem changes in the retinal metabolome over time. The aim of the study was firstly, to investigate post-mortem, time-dependent changes in the rat retinal metabolome and secondly, to compare the metabolite composition of healthy rat ocular tissues. To study post-mortem changes in the rat retinal metabolome, globes were enucleated and stored at 4 °C and sampled at 0, 2, 4, 8, 24 and 48 h post-mortem. To study the metabolite composition of rat ocular tissues, eyes were dissected immediately after culling to isolate the cornea, lens, vitreous and retina, prior to storing at -80 °C. Tissue extracts were subjected to Gas Chromatograph Mass Spectrometry (GC-MS) and Ultra High Performance Liquid Chromatography Mass Spectrometry (UHPLC-MS). Generally, the metabolic composition of the retina was stable for 8 h post-mortem when eyes were stored at 4 °C, but showed increasing changes thereafter. However, some more rapid changes were observed such as increases in TCA cycle metabolites after 2 h post-mortem, whereas some metabolites such as fatty acids only showed decreases in concentration from 24 h. A total of 42 metabolites were identified across the ocular tissues by GC-MS (MSI level 1) and 2782 metabolites were annotated by UHPLC-MS (MSI level 2) according to MSI reporting standards. Many of the metabolites detected were common to all of the tissues but some metabolites showed partitioning between different ocular structures with 655, 297, 93 and 13 metabolites being uniquely detected in the retina, lens, cornea and vitreous respectively. Only a small percentage (1.6%) of metabolites found in the vitreous were only detected in the retina and not other tissues. In conclusion, mass spectrometry-based techniques have been used for the first time to compare the metabolic composition of different ocular tissues. The metabolite composition of the retina stored at 4 °C post-mortem is mostly stable for at least 8 h. Copyright © 2016 Elsevier Ltd. All rights reserved.
Influence of water immersion on the mechanical properties of fiber posts.
Komada, Wataru; Inagaki, Tasuku; Ueda, Yoji; Omori, Satoshi; Hosaka, Keiichi; Tagami, Junji; Miura, Hiroyuki
2017-01-01
The purpose of this study was to evaluate the influence of water immersion on the mechanical properties of three kinds of glass fiber posts and the fracture resistance of structures using resin composites with glass fiber posts. Each post was divided into three groups; a control group and two water immersion groups (30 and 90 days). Flexural strength was determined by three-point bending test. Each structure was divided into two groups; a control group and a water immersion group for 30 days. The fracture strength of structures was determined by a static loading test. In the flexural strength, two kinds of post in water immersion groups showed lower values than control groups. In the fracture strength, two kinds of structures in water immersion group showed lower values than control groups. The prefabricated glass fiber posts and structures using resin composites with glass fiber posts were affected by water immersion. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
An Enhanced Vacuum Cure Technique for On-Aircraft Repair of Carbon-Bismaleimide Composites
NASA Astrophysics Data System (ADS)
Rider, Andrew N.; Baker, Alan A.; Wang, Chun H.; Smith, Graeme
2011-06-01
Carbon/bismaleimide (BMI) composite is increasingly employed in critical load carrying aircraft structures designed to operate at temperatures approaching 180°C. The high post-cure temperature (above 220°C) required to fully react the BMI resin, however, renders existing on-aircraft prepreg or wet layup repair methods invalid. This paper presents a new on-aircraft repair technique for carbon/BMI composites. The composite prepregs are first warm-staged to improve the ability to evacuate entrapped air. Then the patch is cured in the scarf cavity using the vacuum bag technique, followed by off-aircraft post-cure. The fully cured patch then can be bonded using a structural adhesive.
Buller, David B.; Andersen, Peter A.; Walkosz, Barbara J.; Scott, Michael D.; Beck, Larry; Cutter, Gary R.
2017-01-01
During vacations, many individuals receive high-risk sun exposure that is associated with skin cancer. Vacationers in outdoor recreation venues (pretest n=4,347; posttest n=3,986) at warm-weather destination resorts in North America (n=41) were enrolled in a pair-matched, group-randomized pretest-posttest controlled quasi-experimental design in 2012-14. Print, audiovisual, and online messages based on Transportation Theory and Diffusion of Innovation Theory and promoting advanced sun protection (e.g., use of clothing, hats, shade and pre-application/reapplication of sunscreen and reliable cues to high UV) were delivered through resort channels. Vacationers' sun protection practices observed by trained research staff (i.e., body coverage and shade use analyzed individually and in combined scores) did not differ by experimental condition (p>0.05) or intervention implementation (p>0.05). However, recreation venue moderated intervention impact. The intervention improved sun protection at waterside recreation venues (z-score composite: intervention pre=-22.74, post=-15.77; control pre=-27.24, post=-23.24) but not non-waterside venues (z-score composite: intervention pre=20.43, post=20.53; control pre=22.94, post=18.03, p<0.01). An additional analysis showed that resorts with greater program implementation showed more improvements in sun protection by vacationers at waterside (z=score composite: high implementation pre=-25.45, post=-14.05; low implementation pre=-24.70, post=-21.40) compared to non-waterside (z-score composite: high implementation pre=14.51, post=19.98; low implementation pre=24.03, post=18.98, p<0.01) recreation venues. The intervention appeared effective with the vacationers in recreation venues with the highest-risk for sun exposure, waterside venues. However, it was not effective throughout all the resort venues, possibly because of the sun-seeking desires of vacationers, information overload at the resorts, and constraints on clothing styles and sun protection by recreation activity. PMID:28189810
Buller, David B; Andersen, Peter A; Walkosz, Barbara J; Scott, Michael D; Beck, Larry; Cutter, Gary R
2017-06-01
During vacations, many individuals receive high-risk sun exposure that is associated with skin cancer. Vacationers in outdoor recreation venues (pretest n=4347; posttest n=3986) at warm-weather destination resorts in North America (n=41) were enrolled in a pair-matched, group-randomized pretest-posttest controlled quasi-experimental design in 2012-14. Print, audiovisual, and online messages based on Transportation Theory and Diffusion of Innovation Theory and promoting advanced sun protection (e.g., use of clothing, hats, shade and pre-application/reapplication of sunscreen and reliable cues to high UV) were delivered through resort channels. Vacationers' sun protection practices observed by trained research staff (i.e., body coverage and shade use analyzed individually and in combined scores) did not differ by experimental condition (p>0.05) or intervention implementation (p>0.05). However, recreation venue moderated intervention impact. The intervention improved sun protection at waterside recreation venues (z-score composite: intervention pre=-22.74, post=-15.77; control pre=-27.24, post=-23.24) but not non-waterside venues (z-score composite: intervention pre=20.43, post=20.53; control pre=22.94, post=18.03, p<0.01). An additional analysis showed that resorts with greater program implementation showed more improvements in sun protection by vacationers at waterside (z=score composite: high implementation pre=-25.45, post=-14.05; low implementation pre=-24.70, post=-21.40) compared to non-waterside (z-score composite: high implementation pre=14.51, post=19.98; low implementation pre=24.03, post=18.98, p<0.01) recreation venues. The intervention appeared effective with the vacationers in recreation venues with the highest-risk for sun exposure, waterside venues. However, it was not effective throughout all the resort venues, possibly because of the sun-seeking desires of vacationers, information overload at the resorts, and constraints on clothing styles and sun protection by recreation activity. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Durgesh, B. H.; Alkheraif, A. A.; Al Sharawy, M.; Varrela, J.; Vallittu, P. K.
2016-01-01
The aim of this study was to investigate the magnitude of debonding stress of an orthodontic bracket bonded to the enamel with resin systems having different elastic properties. For the same purpose, sixty human premolars were randomly divided into four groups according to the adhesive system used for bonding brackets: G Fix flowable resin (GFI) with Everstick NET (ESN), GFI, G Aenial Universal Flow (GAU) with ESN, and GAU. The brackets were stressed in the occlusogingival direction on a universal testing machine. The values of debonding load and displacement were determined at the point of debonding. The elastic modulus of the tested materials was determined using nanoindentation. An analysis of variance showed a significant difference in the loads required to debond the bracket among the groups tested. The GAU group had the highest elastic modulus, followed by the GFI and ESN groups. ARI (Adhesive Remnant Index) scores demonstrated more remnants of the adhesive material on the bracket surface with adhesives having a higher elastic modulus. Taking into consideration results of the present in-vitro study, it can be concluded that the incorporation of a glass-fiber-reinforced composite resin (FRC) with a low elastic modulus between the orthodontic bracket and enamel increases the debonding force and strain more than with adhesive systems having a higher elastic modulus.
2014-03-01
information modeling guide series: 03—GSA BIM guide for 3D imaging (Ver. 1). Retrieved from http://www.gsa.gov/graphics/pbs/GSA_BIM_Guide_Series_03... model during a KVA knowledge audit at FRC San Diego. The information used in the creation of his KVA models was generated from the SME-provided...Kenney then used the information gathered during SME interviews to reengineer the process to include 3D printing to form his “to-be” model . The
Crack Formation in Powder Metallurgy Carbon Nanotube (CNT)/Al Composites During Post Heat-Treatment
NASA Astrophysics Data System (ADS)
Chen, Biao; Imai, Hisashi; Li, Shufeng; Jia, Lei; Umeda, Junko; Kondoh, Katsuyoshi
2015-12-01
After the post heat-treatment (PHT) process of powder metallurgy carbon nanotubes (CNT)/Al composites, micro-cracks were observed in the composites, leading to greatly degraded mechanical properties. To understand and suppress the crack formation, an in situ observation of CNT/Al composites was performed at elevated temperatures. PHT was also applied to various bulk pure Al and CNT/Al composites fabricated under different processes. It was observed that the composites consolidated by hot-extrusion might form micro-cracks, but those consolidated by spark plasma sintering (SPS) showed no crack after PHT. A high-temperature SPS process before hot-extrusion was effective to prevent crack formation. The release of residual stress in severe plastic deformed (SPD) materials was responsible for the cracking phenomena during the PHT process. Furthermore, a good particle bonding was essential and effective to suppress cracks for SPD materials in the PHT process.
Process and Post-Process: A Discursive History.
ERIC Educational Resources Information Center
Matsuda, Paul Kei
2003-01-01
Examines the history of process and post-process in composition studies, focusing on ways in which terms, such as "current-traditional rhetoric,""process," and "post-process" have contributed to the discursive construction of reality. Argues that use of the term post-process in the context of second language writing needs to be guided by a…
NASA Astrophysics Data System (ADS)
Sinthaworn, S.; Puengpaiboon, U.; Warasetrattana, N.; Wanapaisarn, S.
2018-01-01
Endodontically treated teeth were simulated by finite element analysis in order to estimate ultimate tensile strength of dentin. Structures of the endodontically treated tooth cases are flared root canal, restored with different number of fiber posts {i.e. resin composite core without fiber post (group 1), fiber post No.3 with resin composite core (group 2) and fiber post No.3 accessory 2 fiber posts No.0 with resin composite core (group 3)}. Elastic modulus and Poisson’s ratio of materials were selected from literatures. The models were loaded by the average fracture resistances load of each groups (group 1: 361.80 N, group 2: 559.46 N, group 3: 468.48 N) at 135 degree angulation in respect to the longitudinal axis of the teeth. The stress analysis and experimental confirm that fracture zone is at dentin area. To estimate ultimate tensile strength of dentin, trial and error of ultimate tensile strength were tested to obtain factor of safety (FOS) equal to 1.00. The result reveals that ultimate tensile strength of dentin of group 1, 2, 3 are 38.89, 30.96, 37.19 MPa, respectively.
Su, Fan; Zhao, Ying; Su, Qin
2013-08-01
To evaluate the stress distribution of the cervical-defected incisor with labial or lingual endodontic access with finite element analysis (FEA), and to explore the advantage of resistance in labial endodontic access. 3-D finite element models of upper cervical-defected incisor were established using cone-beam CT (CBCT), Mimics Catia, and Ansys software. The subjects were categorized according to the two endodontic accesses and three restorative ways, which were composite resin, glass fiber-reinforced composite resin and glass fiber-reinforced post-crown. All the models were loaded.The von Mises stress values and distribution were recorded and analyzed with Ansys 10.0 software. In this study, direct composite resin restoration showed no significant difference between the labial and lingual access. In glass fiber-reinforced composite resin, labial access could transfer the stress concentration area. It could reduce the incidence of fracture of the cervical lesion but increase the incidence of root fracture. Post-crown restoration could obviously reduce the incidence of fracture of the cervical lesion. When the cervical-defected incisor is restored with composite resin, labial and lingual accesses can be considered. Labial access with glass fiber-reinforced composite resin or post-crown restoration is a good choice.
Cryogenic-coolant He4-superconductor dynamic and static interactions
NASA Technical Reports Server (NTRS)
Caspi, S.; Chuang, C.; Kim, Y. I.; Allen, R. J.; Frederking, T. H. E.
1980-01-01
A composite superconducting material (NbTi-Cu) was evaluated with emphasis on post quench solid cooling interaction regimes. The quasi-steady runs confirm the existence of a thermodynamic limiting thickness for insulating coatings. Two distinctly different post quench regimes of coated composites are shown to relate to the limiting thickness. Only one regime,, from quench onset to the peak value, revealed favorable coolant states, in particular in He2. Transient recovery shows favorable recovery times from this post quench regime (not drastically different from bare conductors) for both single coated specimens and a coated conductor bundle.
Jeaidi, Zaid Al
2016-01-01
To assess the fracture resistance of endodontically treated teeth with a novel Zirconia (Zr) nano-particle filler containing bulk fill resin composite. Forty-five freshly extracted maxillary central incisors were endodontically treated using conventional step back preparation and warm lateral condensation filling. Post space preparation was performed using drills compatible for fiber posts (Rely X Fiber Post) on all teeth (n=45), and posts were cemented using self etch resin cement (Rely X Unicem). Samples were equally divided into three groups (n=15) based on the type of core materials, ZirconCore (ZC) MulticCore Flow (MC) and Luxacore Dual (LC). All specimens were mounted in acrylic resin and loads were applied (Universal testing machine) at 130° to the long axis of teeth, at a crosshead speed of 0.5 mm/min until failure. The loads and the site at which the failures occurred were recorded. Data obtained was tabulated and analyzed using a statistical program. The means and standard deviations were compared using ANOVA and Multiple comparisons test. The lowest and highest failure loads were shown by groups LC (18.741±3.02) and MC (25.16±3.30) respectively. Group LC (18.741±3.02) showed significantly lower failure loads compared to groups ZC (23.02±4.21) and MC (25.16±3.30) (p<0.01). However groups ZC (23.02±4.21) and MC (25.16±3.30) showed comparable failure loads (p=0.23). Fracture resistance of endodontically treated teeth restored with Zr filler containing bulk fill composite cores was comparable to teeth restored with conventional Zr free bulk fill composites. Zr filled bulk fill composites are recommended for restoration of endodontically treated teeth as they show comparable fracture resistance to conventional composite materials with less catastrophic failures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shieh, Sean R.; Dorfman, Susannah M.; Kubo, Atsushi
The formation and properties of the post-perovskite (CaIrO{sub 3}-type) phase were studied in Fe-rich compositions along the pyrope-almandine ((Mg,Fe){sub 3}Al{sub 2}Si{sub 3}O{sub 12}) join. Natural and synthetic garnet starting materials with almandine fractions from 38 to 90 mol% were studied using synchrotron X-ray diffraction in the laser-heated diamond anvil cell. Single-phase post-perovskite could be successfully synthesized from garnet compositions at pressures above 148 GPa and temperatures higher than 1600 K. In some cases, evidence for a minor amount of Al{sub 2}O{sub 3} post-perovskite was observed for Alm38 and Alm54 compositions in the perovskite + post-perovskite two-phase region. Pressure-volume data formore » the post-perovskite phases collected during decompression show that incorporation of Fe leads to a systematic increase of unit cell volume broadly similar to the variation observed in the (Mg,Fe)SiO{sub 3} system. The presence of Al{sub 2}O{sub 3} increases the stability of perovskite relative to post-perovskite, requiring higher pressures (> 148 GPa) for synthesis of pure post-perovskites. Our data together with those of Tateno et al. (2005) also suggest that in the Al-rich system the presence of Fe has no strong effect on the pressure required to synthesize the pure post-perovskite phase, but the two-phase perovskite and post-perovskite region may be broad and its width dependent on Fe content. Our results suggest that any regions highly enriched in Al{sub 2}O{sub 3} may consist of either the perovskite phase or a mixture of perovskite and post-perovskite phases throughout the entire thickness of the D* region. The observed synthesis pressures (> 148 GPa) for a pure post-perovskite phase are beyond that at the Earth's core-mantle boundary ({approx} 135 GPa).« less
Lazari, Priscilla Cardoso; de Carvalho, Marco Aurélio; Del Bel Cury, Altair A; Magne, Pascal
2018-05-01
Which post-and-core combination will best improve the performance of extensively damaged endodontically treated incisors without a ferrule is still unclear. The purpose of this in vitro study was to investigate the restoration of extensively damaged endodontically treated incisors without a ferrule using glass-ceramic crowns bonded to various composite resin foundation restorations and 2 types of posts. Sixty decoronated endodontically treated bovine incisors without a ferrule were divided into 4 groups and restored with various post-and-core foundation restorations. NfPfB=no-ferrule (Nf) with glass-fiber post (Pf) and bulk-fill resin foundation restoration (B); NfPfP=no-ferrule (Nf) with glass-fiber post (Pf) and dual-polymerized composite resin core foundation restoration (P); NfPt=no-ferrule (Nf) with titanium post (Pt) and resin core foundation restoration; and NfPtB=no-ferrule (Nf) with titanium post (Pt) and bulk-fill resin core foundation restoration (B). Two additional groups from previously published data from the same authors (FPf=2mm of ferrule (F) and glass-fiber post (Pf) and composite resin core foundation restoration; and NfPf=no-ferrule (Nf) with glass-fiber post (Pf) and composite resin core foundation restoration), which were tested concomitantly and using the same experimental arrangement, were included for comparison. All teeth were prepared to receive bonded glass-ceramic crowns luted with dual-polymerized resin cement and were subjected to accelerated fatigue testing under submerged conditions at room temperature. Cyclic isometric loading was applied to the incisal edge at an angle of 30 degrees with a frequency of 5 Hz, beginning with a load of 100 N (5000 cycles). A 100-N load increase was applied every 15000 cycles. The specimens were loaded until failure or to a maximum of 1000 N (140000 cycles). The 6 groups (4 groups from the present study and 2 groups from the previously published study) were compared using the Kaplan-Meier survival analysis (log-rank post hoc test at α=.05 for pairwise comparisons). None of the tested specimen withstood all 140 000 cycles. All specimens without a ferrule were affected by an initial failure phenomenon (wide gap at the lingual margin between the core foundation restoration/crown assembly and the root). NfPfP, NfPt, and NfPtB had similar survival (29649 to 30987 mean cycles until initial failure). NfPfB outperformed NfPt and NfPtB. None of the post-and-core foundation restoration materials were able to match the performance of the ferrule group FPf (72667 cycles). In all groups, 100% of failures were catastrophic. The survival of extensively damaged endodontically treated incisors without a ferrule was slightly improved by the use of a fiber post with a bulk-fill composite resin core foundation restoration. However, none of the post-and-core techniques was able to compensate for the absence of a ferrule. The presence of the posts always adversely affected the failure mode. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
"ComPost": A Writing Program Newsletter and Its Rationale.
ERIC Educational Resources Information Center
Hall, Dennis R.
1993-01-01
Discusses the development and rationale of "ComPost," a weekly newsletter of the Composition Program at the University of Louisville. Suggests that a vehicle like ComPost can promote the communications that contribute to accomplishing collegiality and genuine program consensus. (RS)
Belote, R Travis; Jones, Robert H; Wieboldt, Thomas F
2012-03-01
Human-caused changes in disturbance regimes and introductions of nonnative species have the potential to result in widespread, directional changes in forest community structure. The degree that plant community composition persists or changes following disturbances depends on the balance between local extirpation and colonization by new species, including nonnatives. In this study, we examined species losses and gains, and entry of native vs. exotic species to determine how oak forests in the Appalachian Mountains might shift in species composition following a gradient of pulse disturbances (timber harvesting). We asked (1) how compositional stability of the plant community (resistance and resilience) was influenced by disturbance intensity, (2) whether community responses were driven by extirpation or colonization of species, and (3) how disturbance intensity influenced total and functional group diversity, including the nonnative proportion of the flora through time. We collected data at three spatial scales and three times, including just before, one year post-disturbance, and 10 years post-disturbance. Resistance was estimated using community distance measures between pre- and one year post-disturbance, and resilience using community distance between pre- and 10-year post-disturbance conditions. The number of colonizing and extirpated species between sampling times was analyzed for all species combined and for six functional groups. Resistance and resilience decreased with increasing timber-harvesting disturbance; compositional stability was lower in the most disturbed plots, which was driven by colonization, but not extirpation, of species. Colonization of species also led to increases in diversity after disturbance that was typically maintained after 10 years following disturbance. Most of the community-level responses were driven by post-disturbance colonization of native forbs and graminoids. The nonnative proportion of plant species tended to increase following disturbance, especially at large spatial scales in the most disturbed treatments, but tended to decrease through time following disturbance due to canopy development. The results of this study are consistent with the theory that resources released by disturbance have strong influences on species colonization and community composition. The effects of management activities tested in this study, which span a gradient of timber-harvesting disturbance, shift species composition largely via an increase in species colonization and diversity.
Post-secretion processing influences spider silk performance
Blamires, Sean J.; Wu, Chung-Lin; Blackledge, Todd A.; Tso, I-Min
2012-01-01
Phenotypic variation facilitates adaptations to novel environments. Silk is an example of a highly variable biomaterial. The two-spidroin (MaSp) model suggests that spider major ampullate (MA) silk is composed of two proteins—MaSp1 predominately contains alanine and glycine and forms strength enhancing β-sheet crystals, while MaSp2 contains proline and forms elastic spirals. Nonetheless, mechanical properties can vary in spider silks without congruent amino acid compositional changes. We predicted that post-secretion processing causes variation in the mechanical performance of wild MA silk independent of protein composition or spinning speed across 10 species of spider. We used supercontraction to remove post-secretion effects and compared the mechanics of silk in this ‘ground state’ with wild native silks. Native silk mechanics varied less among species compared with ‘ground state’ silks. Variability in the mechanics of ‘ground state’ silks was associated with proline composition. However, variability in native silks did not. We attribute interspecific similarities in the mechanical properties of native silks, regardless of amino acid compositions, to glandular processes altering molecular alignment of the proteins prior to extrusion. Such post-secretion processing may enable MA silk to maintain functionality across environments, facilitating its function as a component of an insect-catching web. PMID:22628213
[Influence of different types of posts and cores on color of IPS-Empress 2 crown].
Li, Dong-fang; Yang, Jing-yuan; Yang, Xing-mei; Yang, Liu; Xu, Qiang; Guan, Hong-yu; Wan, Qian-bing
2007-10-01
To evaluate the influence of different types of posts and cores on the final color of the IPS-Emperss 2 crown. Five types of posts and cores (Cerapost with Empress cosmo, Cerapost with composite resin, gilded Ni-Cr alloy, gold alloy and Ni-Cr alloy) were made. The shifts in color of three points of IPS-Empress 2 crown surface (cervical, middle and incisal) with different posts and cores was measured with a spectroradiometer (PR-650). The L* a* b* values of zirconium oxide and gilded Ni-Cr alloy posts and cores with ceramic crown were the highest. The L* a* values of zirconium oxide posts composite cores were higher while the b* values were lower. The L* a* b* values of Ni-Cr alloy were lower than that of gold alloy and were the lowest. In combination with IPS-Empress 2 crown, zirconium oxide posts are suitable for routine use in the anterior dentition, and gilded Ni-Cr alloy and gold alloy posts and cores can be recommended for clinical practice. Ni-Cr alloy posts and cores can not be recommended for clinical practice.
Direct restoration of endodontically treated maxillary central incisors: post or no post at all?
von Stein-Lausnitz, Manja; Bruhnke, M; Rosentritt, M; Sterzenbach, G; Bitter, K; Frankenberger, R; Naumann, M
2018-04-30
The aim of this ex-vivo study was to evaluate the impact of cavity size and glass-fiber post (GFP) placement on the load capability of endodontically treated maxillary incisors directly restored with resin composite. Ninety-six extracted human maxillary central incisors were endodontically treated and distributed to four groups (n = 24): access cavity (A), access cavity and uni-proximal class III cavity (U), access cavity and bi-proximal class III cavity (B), and decoronated tooth (D). Specimens were restored with resin composite, and 12 specimen of each group received an adhesively placed glass-fiber post (P). Prior to linear loading, specimens were exposed to thermo-mechanical loading (TCML). Statistical analysis was performed using log-rank test after TCML, Kruskall-Wallis and Mann-Whitney U test to compare load capabilities (F max) . Significantly more failures occurred in group D for specimens without GFP during TCML (p = 0.001). F max (mean (SD) in N was (A) 513 (124), (AP) 554 (201), (U) 438 (171), (UP) 537 (232) (B) 483 (219), (BP) 536 (281), D 143 (181), and DP 500 (331), and differed significantly among groups (p = 0.003). Pair-wise comparison revealed lower F max values for group D compared to all other groups (p < 0.034) except group DP. Endodontically treated maxillary central incisors with cavity sizes up to bi-proximal class III may be successfully directly restored with resin composite. Post placement shows no additional effect except for decoronated endodontically treated incisors. Endodontically treated incisors with access cavities to class III cavities can be successfully restored with resin composite. Post placement for decoronated ETT is recommended.
Sturm, Robert
2016-11-01
Ultrafine particles (UFP) of biogenic and anthropogenic origin occur in high numbers in the ambient atmosphere. In addition, aerosols containing ultrafine powders are used for the inhalation therapy of various diseases. All these facts make it necessary to obtain comprehensive knowledge regarding the exact behavior of UFP in the respiratory tract. Theoretical simulations of local UFP deposition are based on previously conducted inhalation experiments, where particles with various sizes (0.04, 0.06, 0.08, and 0.10 µm) were administered to the respiratory tract by application of the aerosol bolus technique. By the sequential change of the lung penetration depth of the inspired bolus, different volumetric lung regions could be generated and particle deposition in these regions could be evaluated. The model presented in this contribution adopted all parameters used in the experiments. Besides the obligatory comparison between practical and theoretical data, also advanced modeling predictions including the effect of varying functional residual capacity (FRC) and respiratory flow rate were conducted. Validation of the UFP deposition model shows that highest deposition fractions occur in those volumetric lung regions corresponding to the small and partly alveolated airways of the tracheobronchial tree. Particle deposition proximal to the trachea is increased in female probands with respect to male subjects. Decrease of both the FRC and the respiratory flow rate results in an enhancement of UFP deposition. The study comes to the conclusion that deposition of UFP taken up via bolus inhalation is influenced by a multitude of factors, among which lung morphometry and breathing conditions play a superior role.
2016-01-01
Background Ultrafine particles (UFP) of biogenic and anthropogenic origin occur in high numbers in the ambient atmosphere. In addition, aerosols containing ultrafine powders are used for the inhalation therapy of various diseases. All these facts make it necessary to obtain comprehensive knowledge regarding the exact behavior of UFP in the respiratory tract. Methods Theoretical simulations of local UFP deposition are based on previously conducted inhalation experiments, where particles with various sizes (0.04, 0.06, 0.08, and 0.10 µm) were administered to the respiratory tract by application of the aerosol bolus technique. By the sequential change of the lung penetration depth of the inspired bolus, different volumetric lung regions could be generated and particle deposition in these regions could be evaluated. The model presented in this contribution adopted all parameters used in the experiments. Besides the obligatory comparison between practical and theoretical data, also advanced modeling predictions including the effect of varying functional residual capacity (FRC) and respiratory flow rate were conducted. Results Validation of the UFP deposition model shows that highest deposition fractions occur in those volumetric lung regions corresponding to the small and partly alveolated airways of the tracheobronchial tree. Particle deposition proximal to the trachea is increased in female probands with respect to male subjects. Decrease of both the FRC and the respiratory flow rate results in an enhancement of UFP deposition. Conclusions The study comes to the conclusion that deposition of UFP taken up via bolus inhalation is influenced by a multitude of factors, among which lung morphometry and breathing conditions play a superior role. PMID:27942511
Hypercaloric diet prevents sexual impairment induced by maternal food restriction.
Bernardi, M M; Macrini, D J; Teodorov, E; Bonamin, L V; Dalboni, L C; Coelho, C P; Chaves-Kirsten, G P; Florio, J C; Queiroz-Hazarbassanov, N; Bondan, E F; Kirsten, T B
2017-05-01
Prenatal undernutrition impairs copulatory behavior and increases the tendency to become obese/overweight, which also reduces sexual behavior. Re-feeding rats prenatally undernourished with a normocaloric diet can restore their physiological conditions and copulatory behavior. Thus, the present study investigated whether a hypercaloric diet that is administered in rats during the juvenile period prevents sexual impairments that are caused by maternal food restriction and the tendency to become overweight/obese. Female rats were prenatally fed a 40% restricted diet from gestational day 2 to 18. The pups received a hypercaloric diet from postnatal day (PND) 23 to PND65 (food restricted hypercaloric [FRH] group) or laboratory chow (food restricted control [FRC] group). Pups from non-food-restricted dams received laboratory chow during the entire experiment (non-food-restricted [NFR] group). During the juvenile period and adulthood, body weight gain was evaluated weekly. The day of balanopreputial separation, sexual behavior, sexual organ weight, hypodermal adiposity, striatal dopamine and serotonin, serum testosterone, and tumor necrosis factor α (TNF-α) were evaluated. The FRH group exhibited an increase in body weight on PND58 and PND65. The FRC group exhibited an increase in the latency to the first mount and intromission and an increase in serum TNF-α levels but a reduction of dopaminergic activity. The hypercaloric diet reversed all of these effects but increased adiposity. We concluded that the hypercaloric diet administered during the juvenile period attenuated reproductive impairments that were induced by maternal food restriction through increases in the energy expenditure but not the tendency to become overweight/obese. Copyright © 2017 Elsevier Inc. All rights reserved.
How robotics programs influence young women's career choices : a grounded theory model
NASA Astrophysics Data System (ADS)
Craig, Cecilia Dosh-Bluhm
The fields of engineering, computer science, and physics have a paucity of women despite decades of intervention by universities and organizations. Women's graduation rates in these fields continue to stagnate, posing a critical problem for society. This qualitative grounded theory (GT) study sought to understand how robotics programs influenced young women's career decisions and the program's effect on engineering, physics, and computer science career interests. To test this, a study was mounted to explore how the FIRST (For Inspiration and Recognition of Science and Technology) Robotics Competition (FRC) program influenced young women's college major and career choices. Career theories suggested that experiential programs coupled with supportive relationships strongly influence career decisions, especially for science, technology, engineering, and mathematics careers. The study explored how and when young women made career decisions and how the experiential program and! its mentors and role models influenced career choice. Online focus groups and interviews (online and face-to-face) with 10 female FRC alumnae and GT processes (inductive analysis, open coding, categorizations using mind maps and content clouds) were used to generate a general systems theory style model of the career decision process for these young women. The study identified gender stereotypes and other career obstacles for women. The study's conclusions include recommendations to foster connections to real-world challenges, to develop training programs for mentors, and to nurture social cohesion, a mostly untapped area. Implementing these recommendations could help grow a critical mass of women in engineering, physics, and computer science careers, a social change worth pursuing.
A Plasmoid Thruster for Space Propulsion
NASA Technical Reports Server (NTRS)
Koelfgen, Syri J.; Hawk, Clark W.; Eskridge, Richard; Smith, James W.; Martin, Adam K.
2003-01-01
There are a number of possible advantages to using accelerated plasmoids for in-space propulsion. A plasmoid is a compact plasma structure with an integral magnetic field. They have been studied extensively in controlled fusion research and are classified according to the relative strength of the poloidal and toroidal magnetic field (BP and Bt, respectively). An Object with B P t >> 1 is classified as a Field Reverse Configuration (FRC); if B, = Bt, it is called a Spheromak. The plasmoid thruster operates by producing FRC-like plasmoids, and subsequently ejecting them from the device at high velocity. The plasmoid is formed inside of a single turn conical theta-pinch coil. As this process is inductive, there are no electrodes. Similar experiments have yielded plasmoid velocities of at least 50 km/s (l), and calculations indicate that velocities in excess of 100 km/s should be possible. This concept should be capable of producing Isp s in the range of 5,000 - 10,000 s with thrust densities of order 10(exp 5) N/sq m. The current experiment is designed to produce jet powers in the range of 5-10 kW, although the concept should be scalable to several MW s. The plasmoids mass and velocity will be measured with a variety of diagnostics, including internal and external B-dot probes, flux loops, Langmuir probes, high-speed cameras, and a laser interferometer. Also of key importance will be measurements of the efficiency and mass utilization. Simulations of the plasmoid thruster using MOQUI, a time dependent MHD code, will be carried out concurrently with experimental testing.
Dvorak, Melita M; De Joussineau, Cyrille; Carter, D Howard; Pisitkun, Trairak; Knepper, Mark A; Gamba, Gerardo; Kemp, Paul J; Riccardi, Daniela
2008-01-01
Thiazide diuretics are used, worldwide, as the first-choice drug for patients with uncomplicated hypertension. In addition to their anti-hypertensive actions, they increase bone mineral density and reduce the prevalence of fractures, indicating that thiazides may have a role in the management of postmenopausal osteoporosis. Traditionally, the bone-protective effects of thiazides have been attributed to an increase in renal calcium reabsorption, secondary to the inhibition of the sodium chloride cotransporter, NCC, expressed in the kidney distal tubule. Whether thiazides exert a direct osteoanabolic effect independently of their renal action is controversial. Here we demonstrate that freshly frozen sections of human and rat bone express NCC, principally in bone-forming cells, the osteoblasts. In primary and established culture models of osteoblasts, fetal rat calvarial (FRC) and human MG63 cells, NCC protein is virtually absent in proliferating cells while its expression is dramatically increased during differentiation. Thiazides directly stimulate the production of osteoblast markers, runt-related transcription factor 2 (runx2) and osteopontin, in the absence of a proliferative effect. Using overexpression/knockdown studies in FRC cells, we show that thiazides, but not loop diuretics, increase mineralized nodule formation acting on NCC. Overall, our study demonstrates that thiazides stimulate osteoblast differentiation and bone mineral formation independently of their renal actions. In addition to their use as part of a therapeutic treatment plan for elderly, hypertensive individuals, our discovery opens up the possibility that bone-specific drug targeting by thiazides may be developed for the prevention and treatment of osteoporosis in the patient population as a whole. PMID:17656470
Choi, Sanghun; Hoffman, Eric A.; Wenzel, Sally E.; Tawhai, Merryn H.; Yin, Youbing; Castro, Mario
2013-01-01
The purpose of this work was to explore the use of image registration-derived variables associated with computed tomographic (CT) imaging of the lung acquired at multiple volumes. As an evaluation of the utility of such an imaging approach, we explored two groups at the extremes of population ranging from normal subjects to severe asthmatics. A mass-preserving image registration technique was employed to match CT images at total lung capacity (TLC) and functional residual capacity (FRC) for assessment of regional air volume change and lung deformation between the two states. Fourteen normal subjects and thirty severe asthmatics were analyzed via image registration-derived metrics together with their pulmonary function test (PFT) and CT-based air-trapping. Relative to the normal group, the severely asthmatic group demonstrated reduced air volume change (consistent with air trapping) and more isotropic deformation in the basal lung regions while demonstrating increased air volume change associated with increased anisotropic deformation in the apical lung regions. These differences were found despite the fact that both PFT-derived TLC and FRC in the two groups were nearly 100% of predicted values. Data suggest that reduced basal-lung air volume change in severe asthmatics was compensated by increased apical-lung air volume change and that relative increase in apical-lung air volume change in severe asthmatics was accompanied by enhanced anisotropic deformation. These data suggest that CT-based deformation, assessed via inspiration vs. expiration scans, provides a tool for distinguishing differences in lung mechanics when applied to the extreme ends of a population range. PMID:23743399
Association of expiratory airway dysfunction with marked obesity in healthy adult dogs.
Bach, Jonathan F; Rozanski, Elizabeth A; Bedenice, Daniela; Chan, Daniel L; Freeman, Lisa M; Lofgren, Jennifer L S; Oura, Trisha J; Hoffman, Andrew M
2007-06-01
To evaluate the effects of obesity on pulmonary function in healthy adult dogs. 36 Retrievers without cardiopulmonary disease. Dogs were assigned to 1 of 3 groups on the basis of body condition score (1 through 9): nonobese (score, 4.5 to 5.5), moderately obese (score, 6.0 to 6.5), and markedly obese (score, 7.0 to 9.0). Pulmonary function tests performed in conscious dogs included spirometry and measurement of inspiratory and expiratory airway resistance (R(aw)) and specific R(aw) (sR(aw)) during normal breathing and during hyperpnea via head-out whole-body plethysmography. Functional residual capacity (FRC; measured by use of helium dilution), diffusion capacity of lungs for carbon monoxide (DLCO), and arterial blood gas variables (PaO(2), PaCO(2), and alveolar-arterial gradient) were assessed. During normal breathing, body condition score did not influence airway function, DLCO, or arterial blood gas variables. During hyperpnea, expiratory sR(aw) was significantly greater in markedly obese dogs than nonobese dogs and R(aw) was significantly greater in markedly obese dogs, compared with nonobese and moderately obese dogs. Although not significantly different, markedly obese dogs had a somewhat lower FRC, compared with other dogs. In dogs, obesity appeared to cause airflow limitation during the expiratory phase of breathing, but this was only evident during hyperpnea. This suggests that flow limitation is dynamic and likely occurs in the distal (rather than proximal) portions of the airways. Further studies are warranted to localize the flow-limited segment and understand whether obesity is linked to exercise intolerance via airway dysfunction in dogs.
Methods for Measuring Lung Volumes: Is There a Better One?
Tantucci, Claudio; Bottone, Damiano; Borghesi, Andrea; Guerini, Michele; Quadri, Federico; Pini, Laura
2016-01-01
Accurate measurement of lung volumes is of paramount importance to establish the presence of ventilatory defects and give insights for diagnostic and/or therapeutic purposes. It was the aim of this study to measure lung volumes in subjects with respiratory disorders and in normal controls by 3 different techniques (plethysmographic, dilutional and radiographic methods), in an attempt to clarify the role of each of them in performing such a task, without any presumptive 'a priori' superiority of one method above others. Patients andMethods: In different groups of subjects with obstructive and restrictive ventilatory defects and in a normal control group, total lung capacity, functional residual capacity (FRC) and residual volume were measured by body plethysmography, multi-breath helium (He) dilution and radiographic CT scan method with spirometric gating. The 3 methods gave comparable results in normal subjects and in patients with a restrictive defect. In patients with an obstructive defect, CT scan and plethysmography showed similar lung volumes, while on average significantly lower lung volumes were obtained with the He dilution technique. Taking into account that the He dilution technique does primarily measure FRC during tidal breathing, our data suggest that in some patients with an obstructive defect, a number of small airways can be functionally closed at end-expiratory lung volume, preventing He to reach the lung regions subserved by these airways. In all circumstances, both CT scan with spirometric gating and plethysmographic methods provide similar values of lung volumes. In contrast, the He dilution method can measure lower lung volumes in some patients with chronic airflow obstruction. © 2016 S. Karger AG, Basel.
Action of the isolated canine diaphragm on the lower ribs at high lung volumes.
De Troyer, André; Wilson, Theodore A
2014-10-15
The normal diaphragm has an inspiratory action on the lower ribs, but subjects with chronic obstructive pulmonary disease commonly have an inward displacement of the lateral portions of the lower rib cage during inspiration. This paradoxical displacement, conventionally called 'Hoover's sign', has traditionally been attributed to the direct action of radially oriented diaphragmatic muscle fibres. In the present study, the inspiratory intercostal muscles in all interspaces in anaesthetized dogs were severed so that the diaphragm was the only muscle active during inspiration. The displacements of the lower ribs along the craniocaudal and laterolateral axes and the changes in pleural pressure (∆Ppl) and transdiaphragmatic pressure were measured during occluded breaths and mechanical ventilation at different lung volumes between functional residual capacity (FRC) and total lung capacity. From these data, the separate effects on rib displacement of ∆Ppl and of the force exerted by the diaphragm on the ribs were determined. Isolated spontaneous diaphragm contraction at FRC displaced the lower ribs cranially and outward, but this motion was progressively reversed into a caudal and inward motion as lung volume increased. However, although the force exerted by the diaphragm on the ribs decreased with increasing volume, it continued to displace the ribs cranially and outward. These observations suggest that Hoover's sign is usually caused by the decrease in the zone of apposition and, thus, by the dominant effect of ∆Ppl on the lower ribs, rather than an inward pull from the diaphragm. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.
A Finite-Rate-Catalytic Model For Hypersonic Flows Informed By Molecular Dynamics
NASA Astrophysics Data System (ADS)
Schwartzentruber, T. E.; Valentini, P.; Norman, P.; Sorensen, C.
2011-05-01
The implementation of a finite-rate catalytic (FRC) wall boundary condition within a general 3D unstructured CFD solver is described. A set of one-step gas-surface chemical equations and atomistic parameters that deter- mine the reaction rates must be prescribed as input to the model. The chemical rate equations are solved at each wall face in the CFD simulation and result in a net production of species at the wall. In order for a finite- rate gas-surface reaction model to be consistent at equilibrium, it is determined that not all forward and back- ward rates can be specified arbitrarily. Provided that the forward rates for each surface recombination are as- signed, the backward rates must be determined using equilibrium constants that are consistent with the gas- phase chemistry model and thermodynamics. Reactive molecular dynamics (MD) simulations are performed us- ing the ReaxFFSiO potential to investigate oxygen-silica interactions. β-quartz and amorphous SiO2 surfaces are accommodated to a high temperature gas via MD simulation and reach a steady-state surface coverage. In addition to stable surface reconstructions a number of active sites are observed on which recombination occurs. Single collision MD simulations are performed where gas-phase oxygen atoms interact with the most dominant active site. Probabilities of recombination are found to have an exponential trend with gas-surface system temperature. The MD simulations are used to determine the activation energy for Eley-Rideal recombination of oxygen on a specific silica active site which is an important input parameter for the FRC model.
Positioning of electrode plane systematically influences EIT imaging.
Krueger-Ziolek, Sabine; Schullcke, Benjamin; Kretschmer, Jörn; Müller-Lisse, Ullrich; Möller, Knut; Zhao, Zhanqi
2015-06-01
Up to now, the impact of electrode positioning on electrical impedance tomography (EIT) had not been systematically analyzed due to the lack of a reference method. The aim of the study was to determine the impact of electrode positioning on EIT imaging in spontaneously breathing subjects at different ventilation levels with our novel lung function measurement setup combining EIT and body plethysmography. EIT measurements were conducted in three transverse planes between the 3rd and 4th intercostal space (ICS), at the 5th ICS and between the 6th and 7th ICS (named as cranial, middle and caudal) on 12 healthy subjects. Pulmonary function tests were performed simultaneously by body plethysmography to determine functional residual capacity (FRC), vital capacity (VC), tidal volume (VT), expiratory reserve volume (ERV), and inspiratory reserve volume (IRV). Ratios of impedance changes and body plethysmographic volumes were calculated for every thorax plane (ΔIERV/ERV, ΔIVT/VT and ΔIIRV/IRV). In all measurements of a subject, FRC values and VC values differed ≤5%, which confirmed that subjects were breathing at comparable end-expiratory levels and with similar efforts. In the cranial thorax plane the normalized ΔIERV/ERV ratio in all subjects was significantly higher than the normalized ΔIIRV/IRV ratio whereas the opposite was found in the caudal chest plane. No significant difference between the two normalized ratios was found in the middle thoracic plane. Depending on electrode positioning, impedance to volume ratios may either increase or decrease in the same lung condition, which may lead to opposite clinical decisions.
NASA Astrophysics Data System (ADS)
Weber, T. E.; Smith, R. J.; Hsu, S. C.
2016-10-01
Supercritical magnetized collisionless shocks are thought to play a dominant role in the overall partition of energy throughout the universe by converting flow kinetic energy to other forms such as thermal and supra-thermal populations, magnetic field enhancement, turbulence, and energetic particles. The Magnetized Shock Experiment (MSX) at LANL creates conditions similar to those of inner solar system and stellar bow shocks by accelerating hot (100s of eV during translation) dense (1022 - 1023 m-3) Field Reversed Configuration (FRC) plasmoids to 100s of km/s; resulting in β 1, collisionless plasma flows with Msonic and MAlfvén 10. The drifting FRC can be made to impinge upon a variety of static obstacles including: a strong mirror or cusp magnetic field (mimicking magnetically excited shocks such as the Earth's bow shock), plasma pileup from a solid obstacle (similar to the bow shocks of Mercury and the Moon), and a neural gas puff (bow shocks of Venus or the comets). Characteristic shock length and time scales that are both large enough to observe yet small enough to fit within the experiment, enabling study of the complex interplay of kinetic and fluid processes that mediate cosmic shocks and can generate non-thermal distributions, produce density and magnetic field enhancements much greater than predicted by fluid theory, and accelerate particles. An overview of the experimental program will be presented, including recent results. This work is supported by the U.S. DOE, Office of Science, Office of Fusion Energy Sciences under Contract No. DE-AC52-06NA25369.
Distribution and discharge properties of airway receptors in the opossum, Didelphis marsupialis.
Farber, J P; Fisher, J T; Sant'Ambrogio, G
1983-08-01
The distribution and discharge characteristics of airway mechanoreceptors were evaluated using vagal recording in the pentobarbital-anesthetized, artificially ventilated, open-chest adult opossum (Didelphis marsupialis), a marsupial mammal. Of the 114 receptors studied, 20 (18%) were rapidly adapting. Of the slowly adapting receptors (SARs) evaluated, 21 (22%) were in the trachea and 72 (77%) were located more peripherally; the latter group was designated as bronchial SARs. Fifteen (21%) of the bronchial SARs were found in the contralateral lung. Sixty-five percent of tracheal SARs were active at 0 cmH2O transpulmonary pressure (Ptp), whereas 85% were recruited at less than or equal to 2.5 cmH2O Ptp, which corresponds to the functional residual capacity (FRC). Only 53% of bronchial SARs were active at FRC. Tracheal and bronchial SARs with firing thresholds up to 3 cmH2O Ptp showed similar rates of discharge during static lung inflations as Ptp was increased to 20 cmH2O. Static discharge rates of bronchial receptors with firing thresholds greater than 3 cmH2O were lower than for the other groups. After rapid inflation of the lungs (0.3 s) to 10 cmH2O Ptp, SARs showed an adaptation index (percent decrease in firing rate from initial levels) of 26.5%; slow inflation (1.2 s) yielded a significantly lower adaptation index (17.4%). The discharge of both tracheal and bronchial SARs was inhibited during CO2 inhalation. Specific comparisons of airway receptors in the opossum with those of other mammals yield several quantitative and qualitative differences.
Fusion Ignition Rocket Engine with Ballistic Ablative Lithium Liner
NASA Technical Reports Server (NTRS)
Martin, Adam; Eskridge, Richard; Fimognari, Peter J., III.
2005-01-01
Thermo-nuclear fusion may be the key to a high Isp, high specific power (low alpha) propulsion system. In a fusion system energy is liberated within, and imparted directly to, the propellant. In principle, this can overcome the performance limitations inherent in systems that require thermal power transfer across a material boundary, and/or multiple power conversion stages (NTR, NEP). A thermo-nuclear propulsion system, which attempts to overcome some of the problems inherent in the ORION concept, is described. A passive tapered liner is launched behind a vehicle, through a hole in a pusher-plate, that is connected to the vehicle by a shock-absorbing mechanism. A dense FRC plasmoid is then accelerated to high velocity (in excess of 1,000 km/s) and shot through the hole into the liner, when it has reached a given point down-range. The kinetic energy of the FRC is converted into thermal and magnetic-field energy, igniting a fusion bum in the magnetically confined plasma. The fusion reaction serves as an ignition source for the liner, which is made out of detonable materials. The energy liberated in this process is converted to thrust by the pusher-plate, as in the classic ORION concept. However with this concept, the vehicle does not carry a magazine of pre-fabricated pulse-units. A magnetic nozzle may also be used, in place of the pusher-plate. Estimates of the conditions needed to achieve a sufficient gain will be presented, along with a description of the driver characteristics. The incorporation of this concept into the propulsion system of a spacecraft will also be discussed.
Welcome to the Twilight Zone: The Mid-infrared Properties of Post-starburst Galaxies
NASA Astrophysics Data System (ADS)
Alatalo, Katherine; Bitsakis, Theodoros; Lanz, Lauranne; Lacy, Mark; Brown, Michael J. I.; French, K. Decker; Ciesla, Laure; Appleton, Philip N.; Beaton, Rachael L.; Cales, Sabrina L.; Crossett, Jacob; Falcón-Barroso, Jesús; Kelson, Daniel D.; Kewley, Lisa J.; Kriek, Mariska; Medling, Anne M.; Mulchaey, John S.; Nyland, Kristina; Rich, Jeffrey A.; Urry, C. Meg
2017-07-01
We investigate the optical and Wide-field Survey Explorer (WISE) colors of “E+A” identified post-starburst galaxies, including a deep analysis of 190 post-starbursts detected in the 2 μm All Sky Survey Extended Source Catalog. The post-starburst galaxies appear in both the optical green valley and the WISE Infrared Transition Zone. Furthermore, we find that post-starbursts occupy a distinct region of [3.4]-[4.6] versus [4.6]-[12] WISE colors, enabling the identification of this class of transitioning galaxies through the use of broadband photometric criteria alone. We have investigated possible causes for the WISE colors of post-starbursts by constructing a composite spectral energy distribution (SED), finding that the mid-infrared (4-12 μm) properties of post-starbursts are consistent with either 11.3 μm polycyclic aromatic hydrocarbon emission, or thermally pulsating asymptotic giant branch (TP-AGB) and post-AGB stars. The composite SED of extended post-starburst galaxies with 22 μm emission detected with signal-to-noise ratio ≥slant 3 requires a hot dust component to produce their observed rising mid-infrared SED between 12 and 22 μm. The composite SED of WISE 22 μm non-detections (S/N < 3), created by stacking 22 μm images, is also flat, requiring a hot dust component. The most likely source of the mid-infrared emission of these E+A galaxies is a buried active galactic nucleus (AGN). The inferred upper limits to the Eddington ratios of post-starbursts are 10-2-10-4, with an average of 10-3. This suggests that AGNs are not radiatively dominant in these systems. This could mean that including selections capable of identifying AGNs as part of a search for transitioning and post-starburst galaxies would create a more complete census of the transition pathways taken as a galaxy quenches its star formation.
Emily L. Bernhardt; Teresa N. Hollingsworth; F. Stuart Chapin
2011-01-01
Question: How do pre-fire conditions (community composition and environmental characteristics) and climate-driven disturbance characteristics (fire severity) affect post-fire community composition in black spruce stands? Location: Northern boreal forest, interior Alaska. Methods: We compared plant community composition and environmental stand characteristics in 14...
Díaz, María José; Martínez, Elvira; Piñeiro, Concepción; Palavecinos, Mireya; Benayas, Javier; Toribio, M Angeles
2012-07-01
In Spain, hazardous household waste management by citizens occurs via fixed recycling centres (FRC) and mobile recycling centres (MRC) which usually depend on local governments. This paper addresses a request by the Madrid City Council, in an attempt to improve the service it provides to the city of Madrid. The aim of the study involved analysing the information people possess in relation to hazardous waste and to the use of available equipment, and conducting a post-evaluation of the effectiveness of an environmental communication campaign conducted by the Madrid City Council and aimed at providing awareness of the existence of new FRCs and MRCs. To this end, a questionnaire was conducted with 5644 inhabitants of the city of Madrid. Qualitative data was categorized using content analysis followed by chi-squared tests, considering some socio-demographic characteristics of the sample, such as age or place of residence (district). Communication campaigns influenced citizen awareness of what constituted hazardous waste, of how to properly separate waste and of the existence of FRCs and MRCs. However, few citizens actually used FRCs or MRC (18% across four districts), a fact that might be related to a lack of knowledge of downstream waste treatment issues, or to self-limiting hindrances to householders, such as distance to recycling centres. It is recommended that future communication campaigns investigate householder needs and pre-conceptions in relation to recycling, as well as tailored education aimed at addressing the barriers, perceived or otherwise, facing citizens.
Braga, Neilor Mateus Antunes; Souza-Gabriel, Aline Evangelista; Messias, Danielle Cristine Furtado; Rached-Junior, Fuad Jacob Abi; Oliveira, Camila Fávero; Silva, Ricardo Gariba; Silva-Sousa, Yara T Corrêa
2012-01-01
The aim of this study was to assess the influence of surface pretreatments of fiber-reinforced posts on flexural strength (FS), modulus of elasticity (ME) and morphology of these posts, as well as the bond strength (BS) between posts and core material. Fifty-two fiber posts (smooth and serrated) were assigned to 4 groups (n=13): no treatment (control), 10% hydrogen peroxide (HP) for 10 min (HP-10), 24% HP for 1 min (HP-24) and airborne-particle abrasion (Al(2)O(3)). To evaluate FS and ME, a 3-point bending test was performed. Three posts of each group were examined by scanning electron microscopy. Composite resin was used as the core build-up and samples were sectioned to obtain microtensile sticks. Data were analyzed by ANOVA and Tukey's test (α=0.05). For FS, significant differences were observed between posts type and surface pretreatment (p<0.05), with the highest means for the smooth posts. Al2O3 provided higher FS than HP-24. Al(2)O(3) promoted higher ME than HP-24 and control. SEM images revealed partial dissolution of the resin matrix in all treated groups. The smooth posts had higher BS and FS than serrated posts (p<0.05). Mechanical properties of the glass fiber posts and the bond strength between posts and composite material were not altered by the surface treatments, except for airborne-particle abrasion that increased the post elastic modulus.
Kanitakis, Jean; Morelon, Emmanuel
2017-06-01
Vascularized composite tissue allografts include skin, which frequently undergoes, in the early post-graft period, acute rejections. The diagnosis of acute rejection may be difficult as it can be mimicked by several dermatoses. We present a bilateral hand allograft recipient who developed, 16.5 years post-graft, cutaneous lesions raising suspicion about rejection. Physical examination and skin biopsy were diagnostic of scabies. This ectoparasitosis should be added in the list of dermatoses that can mimic allograft rejection in vascular composite allografts. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Ayna, Buket; Yılmaz, Berivan D; Izol, Bozan S; Ayna, Emrah; Tacir, İbrahim Halil
2018-06-15
BACKGROUND The purpose of this study was to determine the influence of 2 different esthetic post materials on the final color of direct-composite restorations by using a digital technique under in vivo conditions. MATERIAL AND METHODS We included 22 pulpless incisor teeth treated with conventionally cemented zirconia (n=11) and polyethylene fiber (n=11) posts in the study. Teeth were restored with a hybrid resin. The color of direct-composite restorations and contralateral control teeth was measured using a digital technique. The Commission Internationale de L'Eclairage, or CIE, L*a*b* and RGB color systems were investigated. Descriptive statistical analysis was performed for the CIE L*a*b* values. Color differences (ΔE) for the average L*, a*, and b* color parameters between every pair of groups were calculated (P>.05). RESULTS Significant differences were not found in the color difference luminosity (lum), R, G, B, and L* a* b* values between the zircon-rich glass fiber post (Z) and contralateral control teeth (Cz) (P>.05) and between the polyethylene fiber post (P) and contralateral control teeth (Cp) (P>.05). However, there was a statistically significant difference between the color a* values of the polyethylene fiber post (P) and contralateral control teeth (Cp) (p<0.05). Color differences (ΔE) between the zircon-rich glass fiber post (Z) and contralateral control teeth, and the polyethylene fiber post (P) and contralateral teeth were not statistically significant (P>.05). CONCLUSIONS Definitive restorations were equally affected by the 2 materials. Both materials can be used reliably in clinical practice. However, further research that focuses on the effect of intraoral conditions is needed.
Evaluating Composite Sampling Methods of Bacillus spores at Low Concentrations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hess, Becky M.; Amidan, Brett G.; Anderson, Kevin K.
Restoring facility operations after the 2001 Amerithrax attacks took over three months to complete, highlighting the need to reduce remediation time. The most time intensive tasks were environmental sampling and sample analyses. Composite sampling allows disparate samples to be combined, with only a single analysis needed, making it a promising method to reduce response times. We developed a statistical experimental design to test three different composite sampling methods: 1) single medium single pass composite: a single cellulose sponge samples multiple coupons; 2) single medium multi-pass composite: a single cellulose sponge is used to sample multiple coupons; and 3) multi-medium post-samplemore » composite: a single cellulose sponge samples a single surface, and then multiple sponges are combined during sample extraction. Five spore concentrations of Bacillus atrophaeus Nakamura spores were tested; concentrations ranged from 5 to 100 CFU/coupon (0.00775 to 0.155CFU/cm2, respectively). Study variables included four clean surface materials (stainless steel, vinyl tile, ceramic tile, and painted wallboard) and three grime coated/dirty materials (stainless steel, vinyl tile, and ceramic tile). Analysis of variance for the clean study showed two significant factors: composite method (p-value < 0.0001) and coupon material (p-value = 0.0008). Recovery efficiency (RE) was higher overall using the post-sample composite (PSC) method compared to single medium composite from both clean and grime coated materials. RE with the PSC method for concentrations tested (10 to 100 CFU/coupon) was similar for ceramic tile, painted wall board, and stainless steel for clean materials. RE was lowest for vinyl tile with both composite methods. Statistical tests for the dirty study showed RE was significantly higher for vinyl and stainless steel materials, but significantly lower for ceramic tile. These results suggest post-sample compositing can be used to reduce sample analysis time when responding to a Bacillus anthracis contamination event of clean or dirty surfaces.« less
Evaluation of a Low Temperature Cure Powder Coating
2008-05-01
4”x6”x1/4” Al 2024-T3 panels were chromate conversion coated by NDCEE per MIL-DTL-5514F Type 1 Class A Reserved for LTCPC 27 – 4”x6”x1/4” Al...2024-T3 panels were chromate conversion coated by FRC Southeast per MIL-DTL- 5514F Type 1 Class A Reserved for baseline coating JSEM - May...conducted under contract W74V8H- 04-D-0005 Task 427. DISCLAIMER: The contents of this document are not to be used for advertising , publication, or
Damping of lower hybrid waves by low-frequency drift waves
NASA Astrophysics Data System (ADS)
Krall, Nicholas A.
1989-11-01
The conditions under which a spectrum of lower hybrid drift waves will decay into low-frequency drift waves (LFD) are calculated. The purpose is to help understand why lower hybrid drift waves are not seen in all field-reversed configuration (FRC) experiments in which they are predicted. It is concluded that if there is in the plasma a LFD wave amplitude above a critical level, lower hybrid waves will decay into low-frequency drift waves. The critical level required to stabilize TRX-2 [Phys. Fluids 30, 1497 (1987)] is calculated and found to be reasonably consistent with theoretical estimates.
NASA Technical Reports Server (NTRS)
1968-01-01
The HL-10 Lifting Body is seen here parked on Rogers Dry Lake, the unique location where it landed after research flights. This 1968 photo shows the vehicle after the fins were modified to remove instabilities encountered on the first flight. It involved a change to the shape of the leading edge of the fins to eliminate flow separation. It required extensive wind-tunnel testing at Langley Research Center, Hampton, Va. NASA Flight Research Center (FRC) engineer Bob Kempel than plotted thousands of data points by hand to come up with the modification, which involved a fiberglass glove backed with a metal structure on each fin's leading edge. This transformed the vehicle from a craft that was difficult to control into the best handling of the original group of lifting bodies at the FRC. The HL-10 was one of five heavyweight lifting-body designs flown at NASA's Flight Research Center (FRC--later Dryden Flight Research Center), Edwards, California, from July 1966 to November 1975 to study and validate the concept of safely maneuvering and landing a low lift-over-drag vehicle designed for reentry from space. Northrop Corporation built the HL-10 and M2-F2, the first two of the fleet of 'heavy' lifting bodies flown by the NASA Flight Research Center. The contract for construction of the HL-10 and the M2-F2 was $1.8 million. 'HL' stands for horizontal landing, and '10' refers to the tenth design studied by engineers at NASA's Langley Research Center, Hampton, Va. After delivery to NASA in January 1966, the HL-10 made its first flight on Dec. 22, 1966, with research pilot Bruce Peterson in the cockpit. Although an XLR-11 rocket engine was installed in the vehicle, the first 11 drop flights from the B-52 launch aircraft were powerless glide flights to assess handling qualities, stability, and control. In the end, the HL-10 was judged to be the best handling of the three original heavy-weight lifting bodies (M2-F2/F3, HL-10, X-24A). The HL-10 was flown 37 times during the lifting body research program and logged the highest altitude and fastest speed in the Lifting Body program. On Feb. 18, 1970, Air Force test pilot Peter Hoag piloted the HL-10 to Mach 1.86 (1,228 mph). Nine days later, NASA pilot Bill Dana flew the vehicle to 90,030 feet, which became the highest altitude reached in the program. Some new and different lessons were learned through the successful flight testing of the HL-10. These lessons, when combined with information from it's sister ship, the M2-F2/F3, provided an excellent starting point for designers of future entry vehicles, including the Space Shuttle.
Lunar Landing Research Vehicle (LLRV) in flight
NASA Technical Reports Server (NTRS)
1967-01-01
In this 1967 NASA Flight Reserch Center photograph the Lunar Landing Research Vehicle (LLRV) is viewed from the front. This photograph provideds a good view of the pilot's platform with the restrictive cockpit view like that of he real Lunar Module (LM) When Apollo planning was underway in 1960, NASA was looking for asimulator to profile the descent to the moon's surface. Three conceptssurfaced: an electronic simulator, a tethered device, and the ambitious Dryden contribution, a free-flying vehicle. All three became serious projects, but eventually the NASA Flight Research Center's (FRC) Lunar Landing Research Vehicle (LLRV) became the most significant one. After conceptual planning and meetings with engineers from Bell Aerosystems Company, Buffalo, N.Y., NASA FRC issued a $3.6 million production contract awarded in 1963, for delivery of the first of two vehicles for flight studies. Built of tubular aluminum alloy like a giant four-legged bedstead, the vehicle wasto simulate a lunar landing profile from around 1500 feet to the moon's surface. The LLRV had a turbofan engine mounted vertically in a gimbal, with 4200 pounds of thrust. The engine, lifted the vehicle up to the test altitude and was then throttled back to support five-sixths of the vehicle's weight, thus simulating the reduced gravity of the moon. Two lift rockets with thrust that could be varied from 100 to 500 pounds handled the LLRV's rate of descent and horizontal translations. Sixteen smaller rockets, mounted in pairs, gave the pilot control in pitch, yaw, and roll.. The pilot's platform extended forward between two legs while an electronics platform, similarly located, extended rearward. The pilot had a zero-zero ejection seat that would then lift him away to safety. The two LLRVs were shipped from Bell to the FRC in April 1964, with program emphasis on vehicle No. 1. The first flight, Oct. 30, 1964, NASA research pilot Joe Walker flew it three times for a total of just under 60 seconds, to a peak altitude of approximately 10 feet. By mid-1966 the NASA Flight Research Center had accumulated enough data from the LLRV flight program to give Bell a contract to deliver three Lunar Landing Training Vehicles (LLTVs) at a cost of $2.5 million each. 1966 ended with the phasing out of the Flight Research Center's portion of the LLRV program. The LLRV #1 had flown 198 flights, with flight times reaching 9-1/2 minutes and altitudes of around 750 feet. In December 1966 vehicle No. 1 was shipped to NASA Manned Spacecraft Center, followed by No. 2 in mid January 1967 with a total of six flights. The two LLRV's were soon joined by the three LLTV's. All five vehicles were relied on for simulation and training of moon landings.
Artopoulou, Ioli-Ioanna; O'Keefe, Kathy L; Powers, John M
2006-01-01
With advances in adhesive dentistry and current emphasis on esthetic restorations, dowel systems have been developed to take advantage of these new techniques. Of interest when using these systems is the interaction between core materials and post materials. This investigation compared the tensile retentive force of two resin composite core materials to two metallic and one non-metallic prefabricated endodontic posts. Two dimensions of core build-up and two post-surface treatments were tested. One hundred twenty posts (stainless steel, titanium alloy, and glass fiber-impregnated resin) were secured in a jig with 4 mm of the post extending into a cylindrical matrix. The matrix formed cylinders with diameters of 3 and 5 mm into which resin composite was inserted. The posts were treated or not treated with a bonding agent. After storage for 24 hours at 100% humidity, five specimens per condition were tested in an Instron testing machine at a crosshead speed of 0.5 mm/min. Failure loads were recorded in kilograms and failure modes were observed under light microscopy (40 x). Four-way analysis of variance and multiple comparison testing were used to compare means at the 0.05 level of significance. The means and standard deviations of tensile loads were calculated. All variables were significant in either main effects or interactions ( p<0.05). Fisher's PLSD intervals for post, core, treatment, and diameter were 2.0, 1.6, 1.6, and 1.6 kg, respectively. In most cases, the retentive force recorded for metallic posts was higher than that of glass fiber posts. Titanium posts had higher retentive forces than did the stainless steel posts. For metallic posts, 5-mm cores provided higher forces than 3-mm cores. In the glass fiber group, core diameter was not significant. For core materials, Build-It gave higher results with stainless steel posts, and FluoroCore gave higher results with the titanium ones. The surface treatment results were mixed. In the metallic post groups the adhesive failure data ranged between 80% and 100%, whereas in the glass fiber post groups, adhesive failures ranged between 60% and 70%. Within the limitations of this study, the metallic post groups always provided higher tensile retentive forces, with the titanium post groups showing higher retentive forces than the stainless steel ones. In the glass fiber post groups, different core diameters did not affect retention values.
Personal network structure and substance use in women by 12 months post treatment intake
Tracy, Elizabeth M.; Min, Meeyoung O.; Park, Hyunyong; Jun, MinKyoung; Brown, Suzanne; Francis, Meredith W.
2015-01-01
Introduction Women with substance use disorders enter treatment with limited personal network resources and reduced recovery support. This study examined the impact of personal networks on substance use by 12 months post treatment intake. Methods Data were collected from 284 women who received substance abuse treatment. At six month follow up, composition, support availability and structure of personal networks were examined. Substance use was measured by women’s report of any use of alcohol or drugs. Hierarchical multivariate logistic regression was conducted to examine the contribution of personal network characteristics on substance use by 12 months post treatment intake. Results Higher numbers of substance using alters (network members) and more densely connected networks at six month follow-up were associated with an increased likelihood of substance use by 12 months post treatment intake. A greater number of isolates in women’s networks was associated with decreased odds of substance use. Women who did not use substances by 12 months post treatment intake had more non-users among their isolates at six months compared to those who used substances. No association was found between support availability and likelihood of substance use. Conclusions Both network composition and structure could be relevant foci for network interventions e.g. helping women change network composition by reducing substance users as well as increasing network connections. Isolates who are not substance users may be a particular strength to help women cultivate within their network to promote sustained sobriety post treatment. PMID:26712040