Sample records for composite patch repair

  1. Experimental Fatigue Study of Composite Patch Repaired Steel Plates with Cracks

    NASA Astrophysics Data System (ADS)

    Karatzas, Vasileios A.; Kotsidis, Elias A.; Tsouvalis, Nicholas G.

    2015-10-01

    Cracks are among the most commonly encountered defects in metallic structures operating at sea. Composite patch repairing is a repair method which is gaining popularity as it counters most of the problems faced by conventional renewal repairs. Extensive studies can be found in the literature addressing the efficiency of this novel repair method using techniques which meet higher performance and monitoring standards than these commonly found in naval applications. In this work the efficiency of practices widely used in the ship repair industry for the implementation of composite patch repairing is addressed. To this end, steel plates repaired with composite patches were tested under fatigue loading. The composite patches consisted of carbon fibers in epoxy matrix and were directly laminated to the steel surface using the vacuum infusion method. Two different surface preparation methods, namely grit-blasting and mechanical treatment with the use of a needle gun were studied. In addition, in order to account for the harsh environmental conditions during the operating life of the structure and to study its effect on the repair, two different aging scenarios were considered. Non-destructive evaluation of the patches was performed so as to assess the quality of the repair, and the evolution of debonding during testing.

  2. Rotator cuff repair with a tendon-fibrocartilage-bone composite bridging patch.

    PubMed

    Ji, Xiaoxi; Chen, Qingshan; Thoreson, Andrew R; Qu, Jin; An, Kai-Nan; Amadio, Peter C; Steinmann, Scott P; Zhao, Chunfeng

    2015-11-01

    To compare the mechanical performance of a rotator cuff repaired with a novel tendon-fibrocartilage-bone composite bridging patch vs the traditional Mason-Allen repair in an in vitro canine model. Twenty shoulders and 10 bridging patches from patellar tendon were harvested. The patches were trimmed and sliced into 2 layers. An infraspinatus tendon tear was created in each shoulder. Modified Mason-Allen sutures were used to repair the infraspinatus tendon to the greater tuberosity, with or without the bridging patch (bridging patch group and controls, respectively). Shoulders were loaded to failure under displacement control at a rate of 0.5mm/s. The ultimate tensile load was significantly higher in the bridging patch group than control (mean [SD], 365.46 [36.45] vs 272.79 [48.88] N; P<.001). Stiffness at the greater tuberosity repair site and the patch-infraspinatus tendon repair site was significantly higher than the control repair site (93.96 [27.72] vs 42.62 [17.48] N/mm P<.001; 65.94 [24.51] vs 42.62 [17.48] N/mm P=.02, respectively). The tendon-fibrocartilage-bone composite bridging patch achieved higher ultimate tensile load and stiffness at the patch-greater tuberosity repair site compared with traditional repair in a canine model. This composite tissue transforms the traditional tendon-to-bone healing interface (with dissimilar tissues) into a pair of bone-to-bone and tendon-to-tendon interfaces, which may improve healing quality and reduce retear rate. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. A study of tensile residual strength of composite laminates under different patch-repaired series

    NASA Astrophysics Data System (ADS)

    Ding, M. H.; zhan, S.; Tang, Y. H.; Wang, L.; Ma, D. Q.; Wang, R. G.

    2017-09-01

    The tensile behavior of composite laminate structures repaired by bonding external patches was studied in the paper. Two different types of patches including wedge patches and inverted wedge patches were used and failure mechanisms, failure load and strength predictions were studied. A convenient and fast method of building 2-D finite element modeling (FEM) of laminate structure repaired was proposed and the strength of repaired laminate structures was calculated by FEM. The results showed that more than 80% tensile strength of the undamaged laminate could be recovered by bonding patch repairs. Moreover, the results indicated that the strength of inverted wedge patches repair were higher than that of wedge patches repair. FEM simulation results indicated that high stress concentration was found along the edges of invert patches and the most weakness part located in the adhesive bondline. FEM analysis results showed that the strength predicted matched well with the test strength.

  4. Rotator Cuff Repair with a Tendon-Fibrocartilage-Bone Composite Bridging Patch

    PubMed Central

    Ji, Xiaoxi; Chen, Qingshan; Thoreson, Andrew R.; Qu, Jin; An, Kai-Nan; Amadio, Peter C.; Steinmann, Scott P.; Zhao, Chunfeng

    2015-01-01

    Background To compare the mechanical performance of a rotator cuff repaired with a novel tendon-fibrocartilage-bone composite bridging patch vs the traditional Mason-Allen repair in an in vitro canine model. Methods Twenty shoulders and 10 bridging patches from patellar tendon were harvested. The patches were trimmed and sliced into 2 layers. An infraspinatus tendon tear was created in each shoulder. Modified Mason-Allen sutures were used to repair the infraspinatus tendon to the greater tuberosity, with or without the bridging patch (bridging patch group and controls, respectively). Shoulders were loaded to failure under displacement control at a rate of 0.5mm/sec. Findings The ultimate tensile load was significantly higher in the bridging patch group than control (mean [SD], 365.46 [36.45] vs 272.79 [48.88] N; P<.001). Stiffness at the greater tuberosity repair site and the patch-infraspinatus tendon repair site was significantly higher than the control repair site (93.96 [27.72] vs 42.62 [17.48] N/mm P<.001; 65.94 [24.51] vs 42.62 [17.48] N/mm P=.02, respectively). Interpretation The tendon-fibrocartilage-bone composite bridging patch achieved higher ultimate tensile load and stiffness at the patch–greater tuberosity repair site compared with traditional repair in a canine model. This composite tissue transforms the traditional tendon-to-bone healing interface (with dissimilar tissues) into a pair of bone-to-bone and tendon-to-tendon interfaces, which may improve healing quality and reduce retear rate. PMID:26190097

  5. Composite Structures Repair Development at Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Cox, Sarah B.

    2015-01-01

    This presentation discusses the development and results of composite patch repair perfromed at Kennedy Space Center. This includes impact damage, patch repair methods, nondestructive evaluation, and edgewise compression testing.

  6. Prediction of Fatigue Crack Growth of Repaired Al-alloy Structures with Double Sides

    NASA Astrophysics Data System (ADS)

    Benachour, M.; Benachour, N.; Benguediab, M.; Seriari, F. Z.

    During navigation, aircrafts are subject to fatigue damage. In order to rehabilitate damaged structures some techniques are often used to resolve this problem. Efficient repair technique, called composite patch repair, was used to reinforce the damaged structures and stop cracks. In this paper, effect of composite patch repair (Boron/Epoxy) on fatigue crack growth (FCG) was investigated on 2219 T62 Al-alloy. Effects of double patch repair in single notch tensile specimen (SENT) on FCG were studied and compared to single patch repair. Results show beneficial effect of patch repair on fatigue life and FCGR in comparison with the un-patched specimen. In addition, effect of mean stress characterized by stress ratio was highlighted. Fatigue behavior of investigated Al-alloy was compared.

  7. Structural Durability of Damaged Metallic Panel Repaired with Composite Patches

    NASA Technical Reports Server (NTRS)

    Minnetyan, Levon; Chamis, Christos C.

    1997-01-01

    Structural durability/damage tolerance characteristics of an aluminum tension specimen possessing a short crack and repaired by applying a fiber composite surface patch is investigated via computational simulation. The composite patch is made of graphite/epoxy plies with various layups. An integrated computer code that accounts for all possible failure modes is utilized for the simulation of combined fiber-composite/aluminum structural degradation under loading. Damage initiation, growth, accumulation, and propagation to structural fracture are included in the simulation. Results show the structural degradation stages due to tensile loading and illustrate the use of computational simulation for the investigation of a composite patch repaired cracked metallic panel.

  8. Static Tensile and Transient Dynamic Response of Cracked Aluminum Plate Repaired with Composite Patch - Numerical Study

    NASA Astrophysics Data System (ADS)

    Khalili, S. M. R.; Shariyat, M.; Mokhtari, M.

    2014-06-01

    In this study, the central cracked aluminum plates repaired with two sided composite patches are investigated numerically for their response to static tensile and transient dynamic loadings. Contour integral method is used to define and evaluate the stress intensity factors at the crack tips. The reinforcement for the composite patches is carbon fibers. The effect of adhesive thickness and patch thickness and configuration in tensile loading case and pre-tension, pre-compression and crack length effect on the evolution of the mode I stress intensity factor (SIF) (KI) of the repaired structure under transient dynamic loading case are examined. The results indicated that KI of the central cracked plate is reduced by 1/10 to 1/2 as a result of the bonded composite patch repair in tensile loading case. The crack length and the pre-loads are more effective in repaired structure in transient dynamic loading case in which, the 100 N pre-compression reduces the maximum KI for about 40 %, and the 100 N pre-tension reduces the maximum KI after loading period, by about 196 %.

  9. Methods of Making and Using Shape Memory Polymer Composite Patches

    NASA Technical Reports Server (NTRS)

    Hood, Patrick J.

    2011-01-01

    A method of repairing a composite component having a damaged area including: laying a composite patch over the damaged area: activating the shape memory polymer resin to easily and quickly mold said patch to said damaged area; deactivating said shape memory polymer so that said composite patch retains the molded shape; and bonding said composite patch to said damaged part.

  10. Fabrication and Characterization of Multi-Walled Carbon Nanotube (MWCNT) and Ni-Coated Multi-Walled Carbon Nanotube (Ni-MWCNT) Repair Patches for Carbon Fiber Reinforced Composite Systems

    NASA Technical Reports Server (NTRS)

    Johnson, Brienne; Caraccio, Anne; Tate, LaNetra; Jackson, Dionne

    2011-01-01

    Multi-walled carbon nanotube (MWCNT)/epoxy and nickel-coated multi-walled carbon nanotube (Ni-MWCNT)/epoxy systems were fabricated into carbon fiber composite repair patches via vacuum resin infusion. Two 4 ply patches were manufactured with fiber orientations of [90/ 90/ 4590] and [0/90/ +45/ -45]. Prior to resin infusion, the MWCNT/Epoxy system and NiMWCNT/ epoxy systems were optimized for dispersion quality. Scanning electron microscopy (SEM) and optical microscopy (OM) were used to determine the presence ofcarbon nanotubes and assess dispersion quality. Decomposition temperatures were determined via thermogravametric analysis (TGA). SEM and TGA were also used to evaluate the composite repair patches.

  11. A smart composite patch for the repair of aircraft structures

    NASA Astrophysics Data System (ADS)

    Wakha, Kelah; Samuel, Paul; Pines, Darryll J.

    2005-05-01

    Recent interest in bonded composite patch repair technology for aerospace systems is because this method can be carried out at a reduced cost and time and can easily be applied to complex geometric structures. This paper details the development of a dual stiffness/energy sensor for monitoring the integrity of a composite patch used to repair an aluminum structural component. The smart sensor has the ability to predict the elastic field of a given host structure based on the strain state of two sub-sensors integrated into the structure. The present study shows the possibility of using the sensor to deduce the local instantaneous host stiffness. Damaged structures are characterized by a reduction in their elastic stiffness that evolve from microstructural defects. A local smart sensor can be developed to sense the local average properties on a host. In this paper, sensors are attached to a structure and a modified Eshelby's equivalent inclusion method is used to derive the elastic properties of the host. An analytical derivation and a sensitivity analysis for the quasistatic application is given in a papers by Majed, Dasgupta, Kelah and Pines. A summary of the derivation of the dynamic Eshelby tensor is presented. This is of importance because damage detection in structures undergoing vibratory and other motions present a greater challenge than those in quasistatic motion. An in-situ health monitoring active sensor system for a real structure (an aluminum plate with an attached repair patch) under close-to real lifecycle loading conditions is developed. The detection of the onset of any damage to the structure as well as the repair patch and the subsequent monitoring of the growth of this damage constitute important goals of the system. Both experimental and finite element methods were applied. Experimental results are presented for tests of the aluminum plate with the repair patch under monotonic quasi-static and dynamic loading vibratory conditions. In summary, the study shows that smart bonded composite repair patches are very effective in the repair of thin aluminum structures since they are able to determine the integrity of the repair structure as well as the repair patch.

  12. Thermal Analysis by Numerical Methods of Debonding Effects near the Crack Tip under Composite Repairs

    NASA Astrophysics Data System (ADS)

    Tsamasphyros, G. J.; Kanderakis, G. N.; Marioli-Riga, Z. P.

    2003-05-01

    Composite patch repair of metallic structures has become a rapidly grown technology in the aerospace field due to the demand for significant increases in the useful life of both military and civilian aircraft. This has led to significant advances overall in the repair technology of cracked metallic structures. Adhesively bonded composite reinforcements offer remarkable advantages such as mechanical efficiency, repair time, cost reduction, high structural integrity, repair inspectability, damage tolerance to further causes of future strains, anticorrosion and antifretting properties. However, because of the different nature and properties of the materials that form a repair (metals, composites, adhesives), side-effects may occur: debonding due to high stress concentration in the vicinity of the crack, thermal residual stresses because of different thermal expansion coefficients of the adherents, etc. In this paper a three-dimensional finite elements analysis of the area around a patch repaired crack of a typical aircraft fuselage is performed, taking into account both the properties and the geometry of the involved materials. Examined in this case are 2024-T3 aluminum alloy as base material, FM-73 as the adhesive system and F4/5521 boron/epoxy prepreg as the patch material. Through the thickness stresses near the crack tip and along the patch edges with and without temperature effects are calculated and debonding near the crack tip is examined. Finally, the calculated results are compared with existing theories.

  13. Damage Assessment of Composite Structures Using Digital Image Correlation

    NASA Astrophysics Data System (ADS)

    Caminero, M. A.; Lopez-Pedrosa, M.; Pinna, C.; Soutis, C.

    2014-02-01

    The steady increase of Carbon-Fiber Reinforced Polymer (CFRP) Structures in modern aircraft will reach a new dimension with the entry into service of the Boeing 787 and Airbus 350. Replacement of damaged parts will not be a preferable solution due to the high level of integration and the large size of the components involved. Consequently the need to develop repair techniques and processes for composite components is readily apparent. Bonded patch repair technologies provide an alternative to mechanically fastened repairs with significantly higher performance, especially for relatively thin skins. Carefully designed adhesively bonded patches can lead to cost effective and highly efficient repairs in comparison with conventional riveted patch repairs that cut fibers and introduce highly strained regions. In this work, the assessment of the damage process taking place in notched (open-hole) specimens under uniaxial tensile loading was studied. Two-dimensional (2D) and three-dimensional (3D) Digital Image Correlation (DIC) techniques were employed to obtain full-field surface strain measurements in carbon-fiber/epoxy T700/M21 composite plates with different stacking sequences in the presence of an open circular hole. Penetrant enhanced X-ray radiographs were taken to identify damage location and extent after loading around the hole. DIC strain fields were compared to finite element predictions. In addition, DIC techniques were used to characterise damage and performance of adhesively bonded patch repairs in composite panels under tensile loading. This part of work relates to strength/stiffness restoration of damaged composite aircraft that becomes more important as composites are used more extensively in the construction of modern jet airliners. The behaviour of bonded patches under loading was monitored using DIC full-field strain measurements. Location and extent of damage identified by X-ray radiography correlates well with DIC strain results giving confidence to the technique for structural health monitoring of bonded patches.

  14. UV-cured adhesives for carbon fiber composite applications

    NASA Astrophysics Data System (ADS)

    Lu, Hsiao-Chun

    Carbon fiber composite materials are increasingly used in automobile, marine, and aerospace industries due to their unique properties, including high strength, high stiffness and low weight. However, due to their brittle characteristic, these structures are prone to physical damage, such as a bird strike or impact damage. Once the structure is damaged, it is important to have fast and reliable temporary repair until the permanent repair or replacement can take place. In this dissertation, UV-based adhesives were used to provide a bonding strength for temporary repair. Adhesively bonded patch repair is an efficient and effective method for temporary repair. In this study, precured patches (hard patches) and dry fabric patches with laminating resins (soft patches) were performed. UV-based epoxy adhesives were applied to both patch repair systems. For precured patch repair, the bonding strengths were investigated under different surface treatments for bonding area and different adhesives thicknesses. The shear stresses of different UV exposure times and curing times were tested. Besides, the large patch repair was investigated as well. For soft patch repair, the hand wet lay-up was applied due to high viscosity of UV resins. A modified single lap shear testing (ASTM D5868) was applied to determine the shear stress. The large patches used fiber glass instead of carbon fiber to prove the possibility of repair with UV epoxy resin by hand wet lay-up process. The hand lay-up procedure was applied and assisted by vacuum pressure to eliminate the air bubbles and consolidate the patches. To enhance the bonding strength and effective soft patch repair, vacuum assisted resin transferring molding (VaRTM) is the better option. However, only low viscosity resins can be operated by VaRTM. Hence, new UV-based adhesives were formulated. The new UV-based adhesives included photoinitiator (PI), epoxy and different solvents. Solvents were used to compound the photoinitiator into epoxy monomer. Acetone, tetrahydrofuran (THF) and chloroform were used as well as their anhydrous solvents. The UV exposure times and curing times of new UV-based resins were tested. FT-IR, DSC and DMA were used to investigate structure, glass transition temperatures(Tg) and properties of polymer. In summary, the UV-based adhesive was applied to adhesively bonded hard patch and soft patch repair. In addition, new UV-based resins were formulated for the VaRTM process. The in-field repair can be effective and efficient by using UV adhesives.

  15. Method for Qualification of Composite Repairs for Pipelines: Patch Repairs and Considerations for Cathodic Protection

    DOT National Transportation Integrated Search

    2009-12-03

    While the mechanical properties of composite repairs for pipelines have been investigated extensively, the performance of the entire metal-composite system has not been addressed with regard to corrosion of the substrate, water intrusion at the compo...

  16. Formulation and Evaluation of a Novel Adhesive Film for Use in Composite Patch Repair

    NASA Astrophysics Data System (ADS)

    Tsamasphyros, G.; Kalkanis, K.; Maroulas, P.; Anthoulis, G. I.; Grigoryeva, O.

    2008-08-01

    The current work focuses on the testing of a novel material used as an adhesive film in Composite Patch Repair (CPR). A series of Differential Scanning Calorimetry (DSC) results along with various curing cycles not only led to the optimum material composition but also demonstrated the compatibility to the composite pre-impregnated patches. This in turn was subjected to mechanical testing including shear strength measurements. The substrate was chosen to be 2017 T4 aluminium alloy which is customarily used in the aerospace industry, taking into account that CPR is a technique mainly applied in this field. The subsequent surface preparation of the specimens was investigated for the specified context resulting to the selection of the Ferric Sulphate Sulphuric acid etching process. Finally, a series of specimens representing actual skin repairs were created and subjected to cyclic loading, specifying the suitability of the novel material, compared to commercially available materials.

  17. Development of a Hard-Patch Approach for Scarf Repair of Composite Structure

    DTIC Science & Technology

    2006-06-01

    composite skins are bonded to a Ti- 6Al - 4V titanium alloy splice plate. The inboard and outboard ribs are also made of this alloy, as is the root rib which...operation. Options for the patch material include composite laminate, titanium alloy sheet laminate or solid titanium alloy. d) Semi-Hard Patch – The...patch is manufactured from a series of pre-cured composite laminates each containing several plies or titanium sheets, which are interleaved with

  18. An Enhanced Vacuum Cure Technique for On-Aircraft Repair of Carbon-Bismaleimide Composites

    NASA Astrophysics Data System (ADS)

    Rider, Andrew N.; Baker, Alan A.; Wang, Chun H.; Smith, Graeme

    2011-06-01

    Carbon/bismaleimide (BMI) composite is increasingly employed in critical load carrying aircraft structures designed to operate at temperatures approaching 180°C. The high post-cure temperature (above 220°C) required to fully react the BMI resin, however, renders existing on-aircraft prepreg or wet layup repair methods invalid. This paper presents a new on-aircraft repair technique for carbon/BMI composites. The composite prepregs are first warm-staged to improve the ability to evacuate entrapped air. Then the patch is cured in the scarf cavity using the vacuum bag technique, followed by off-aircraft post-cure. The fully cured patch then can be bonded using a structural adhesive.

  19. Lightweight Material Patches Allow for Quick Repairs

    NASA Technical Reports Server (NTRS)

    2010-01-01

    Cornerstone Research Group Inc., of Dayton, Ohio, has been the recipient of 16 Small Business Innovation Research (SBIR) contracts with NASA with a variety of different focuses, including projects like creating inflatable structures for radio frequency antennas and, most recently, healable polymer matrix composites for future space vehicles. One of its earlier SBIR contracts, with Kennedy Space Center, led to the development of a new type of structural patch for a variety of consumer uses: Rubbn Repair, for automotive uses; and Rec Repair for the outdoors and adventure market. Both are flexible, heat-activated structural patches.

  20. New In-Field Composite Repair Techniques for Transmission or Distribution Pipelines

    DOT National Transportation Integrated Search

    2009-05-18

    In-field repair of a damaged pipeline must be performed safely, efficiently, rapidly and reliably. Reinforcement of damaged pipelines is typically accomplished by welding a repair patch and then recoating the repaired area. The welded full-encircleme...

  1. Repair Types, Procedures - Part 1

    DTIC Science & Technology

    2010-05-01

    Affordable Combat Aircraft, AGARD - CP -600, 1997. [17] Helbling J, Grover R and Ratwani M. M “Analysis and Structural Test of Composite Reinforcement to...considered suitable for the composite patch repair of aluminum structure. Ductile adhesives such as FM- 73 are preferred over brittle adhesives Repair Types...zone. A proper cure cycle is followed as prescribed by the adhesive manufacturer. For FM- 73 adhesive cure at 2500F (1210C) for 120 minutes is

  2. Advanced optimal design concepts for composite material aircraft repair

    NASA Astrophysics Data System (ADS)

    Renaud, Guillaume

    The application of an automated optimization approach for bonded composite patch design is investigated. To do so, a finite element computer analysis tool to evaluate patch design quality was developed. This tool examines both the mechanical and the thermal issues of the problem. The optimized shape is obtained with a bi-quadratic B-spline surface that represents the top surface of the patch. Additional design variables corresponding to the ply angles are also used. Furthermore, a multi-objective optimization approach was developed to treat multiple and uncertain loads. This formulation aims at designing according to the most unfavorable mechanical and thermal loads. The problem of finding the optimal patch shape for several situations is addressed. The objective is to minimize a stress component at a specific point in the host structure (plate) while ensuring acceptable stress levels in the adhesive. A parametric study is performed in order to identify the effects of various shape parameters on the quality of the repair and its optimal configuration. The effects of mechanical loads and service temperature are also investigated. Two bonding methods are considered, as they imply different thermal histories. It is shown that the proposed techniques are effective and inexpensive for analyzing and optimizing composite patch repairs. It is also shown that thermal effects should not only be present in the analysis, but that they play a paramount role on the resulting quality of the optimized design. In all cases, the optimized configuration results in a significant reduction of the desired stress level by deflecting the loads away from rather than over the damage zone, as is the case with standard designs. Furthermore, the automated optimization ensures the safety of the patch design for all considered operating conditions.

  3. The effectiveness of an adhesively bonded composite patch repair as applied to a transport aircraft lower wing skin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruschau, J.J.; Coate, J.E.

    1996-12-31

    Specimens were machined from lower wing skin extrusions of a transport aircraft, precracked under fatigue loading, repaired with a boron/epoxy patch, and subsequently fatigue tested under simulated flight loading conditions to evaluate the effectiveness of an adhesively bonded repair patch. Testing was performed at RT and -54{degrees}C for two configurations: one with the crack running up the integral stiffener (riser), the other running down the riser towards the outer skin surface. Cracks were initiated from a single 6.35 mm diameter hole located in the riser portion of the 7075-T6 wing skin material. Ultrasonic inspections were performed during fatigue loading tomore » determine crack growth and damage underneath the patch. Limited results show the adhesively bonded patch was successful in stopping or greatly reducing any further crack growth. Under laboratory air conditions, no crack growth occurred following 30,000 equivalent flight hours, double the expected life of the patched structure. Similarly at -54{degrees}C, no crack growth was observed for a patched crack growing up the riser following 15,000 EFH. For the case of a crack growing down the riser at the lower test temperature, some crack growth was measured, though at a greatly reduced rate.« less

  4. Bonded repair of composite aircraft structures: A review of scientific challenges and opportunities

    NASA Astrophysics Data System (ADS)

    Katnam, K. B.; Da Silva, L. F. M.; Young, T. M.

    2013-08-01

    Advanced composite materials have gained popularity in high-performance structural designs such as aerospace applications that require lightweight components with superior mechanical properties in order to perform in demanding service conditions as well as provide energy efficiency. However, one of the major challenges that the aerospace industry faces with advanced composites - because of their inherent complex damage behaviour - is structural repair. Composite materials are primarily damaged by mechanical loads and/or environmental conditions. If material damage is not extensive, structural repair is the only feasible solution as replacing the entire component is not cost-effective in many cases. Bonded composite repairs (e.g. scarf patches) are generally preferred as they provide enhanced stress transfer mechanisms, joint efficiencies and aerodynamic performance. With an increased usage of advanced composites in primary and secondary aerospace structural components, it is thus essential to have robust, reliable and repeatable structural bonded repair procedures to restore damaged composite components. But structural bonded repairs, especially with primary structures, pose several scientific challenges with the current existing repair technologies. In this regard, the area of structural bonded repair of composites is broadly reviewed - starting from damage assessment to automation - to identify current scientific challenges and future opportunities.

  5. Laparoscopic repair of perforated peptic ulcer: patch versus simple closure.

    PubMed

    Abd Ellatif, M E; Salama, A F; Elezaby, A F; El-Kaffas, H F; Hassan, A; Magdy, A; Abdallah, E; El-Morsy, G

    2013-01-01

    Laparoscopic correction of perforated peptic ulcer (PPU) has become an accepted way of management. Patch omentoplasty stayed for decades the main method of repair. The goal of the present study was to evaluate whether laparoscopic simple repair of PPU is as safe as patch omentoplasty. Since June 2005, 179 consecutive patients of PPU were treated by laparoscopic repair at our centers. We conducted a retrospective chart review in December 2012. Group I (patch group) included patients who were treated with standard patch omentoplasty. Group II (non-patch group) included patients who received simple repair without patch. From June 2007 to Dec. 2012, 179 consecutive patients of PPU who were treated by laparoscopic repair at our centers were enrolled in this multi-center retrospective study. 108 patients belong to patch group. While 71 patients were treated with laparoscopic simple repair. Operative time was significantly shorter in group II (non patch) (p = 0.01). No patient was converted to laparotomy. There was no difference in age, gender, ASA score, surgical risk (Boey's) score, and incidence of co-morbidities. Both groups were comparable in terms of hospital stay, time to resume oral intake, postoperative complications and surgical outcomes. Laparoscopic simple repair of PPU is a safe procedure compared with the traditional patch omentoplasty in presence of certain selection criteria. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  6. Stress Analysis of Adhesively Bonded Repairs to Fibre Composite Structures,

    DTIC Science & Technology

    1981-03-01

    which is bonded to a thin sheet of fibre composite material. The x and y axes are taken in a plane parallel to the midsurface of the sheet with the z...SHEET vI X1 FIG. 1 AXIS SYSTEM IN PATCH related to the displacements at the midsurface of the patch, which we will denote by uo, vo and w, and the...displacements at the midsurface of the sheet, which we will denote by u, vs and w, by the following expression: T ( =uo - us +f7 ’ f/fg + (VO - v, +f 7 3)f4

  7. Corrosion Potential Monitoring for Polymer Composite Wrapping and Galvanic CP System for Reinforced Concrete Marine Piles

    DTIC Science & Technology

    2010-02-01

    deteriorated – Rebar corrosion – Spalling concrete Repair Options • Patching • Polymeric composite wraps • Pre-fabricated composite shell with CP Objective... Corrosion Potential Monitoring for Polymer Composite Wrapping and Galvanic CP System for Reinforced Concrete Marine Piles David Bailey, Richard...Command DoD Corrosion Problem • Piers and wharves – Critical facilities – $14.5M maintenance costs – Reinforced concrete piles • Aged and

  8. Surgery for left ventricular aneurysm: early and late survival after simple linear repair and endoventricular patch plasty.

    PubMed

    Lundblad, Runar; Abdelnoor, Michel; Svennevig, Jan Ludvig

    2004-09-01

    Simple linear resection and endoventricular patch plasty are alternative techniques to repair postinfarction left ventricular aneurysm. The aim of the study was to compare these 2 methods with regard to early mortality and long-term survival. We retrospectively reviewed 159 patients undergoing operations between 1989 and 2003. The epidemiologic design was of an exposed (simple linear repair, n = 74) versus nonexposed (endoventricular patch plasty, n = 85) cohort with 2 endpoints: early mortality and long-term survival. The crude effect of aneurysm repair technique versus endpoint was estimated by odds ratio, rate ratio, or relative risk and their 95% confidence intervals. Stratification analysis by using the Mantel-Haenszel method was done to quantify confounders and pinpoint effect modifiers. Adjustment for multiconfounders was performed by using logistic regression and Cox regression analysis. Survival curves were analyzed with the Breslow test and the log-rank test. Early mortality was 8.2% for all patients, 13.5% after linear repair and 3.5% after endoventricular patch plasty. When adjusted for multiconfounders, the risk of early mortality was significantly higher after simple linear repair than after endoventricular patch plasty (odds ratio, 4.4; 95% confidence interval, 1.1-17.8). Mean follow-up was 5.8 +/- 3.8 years (range, 0-14.0 years). Overall 5-year cumulative survival was 78%, 70.1% after linear repair and 91.4% after endoventricular patch plasty. The risk of total mortality was significantly higher after linear repair than after endoventricular patch plasty when controlled for multiconfounders (relative risk, 4.5; 95% confidence interval, 2.0-9.7). Linear repair dominated early in the series and patch plasty dominated later, giving a possible learning-curve bias in favor of patch plasty that could not be adjusted for in the regression analysis. Postinfarction left ventricular aneurysm can be repaired with satisfactory early and late results. Surgical risk was lower and long-term survival was higher after endoventricular patch plasty than simple linear repair. Differences in outcome should be interpreted with care because of the retrospective study design and the chronology of the 2 repair methods.

  9. Finite element modeling to determine thermal residual strain distribution of bonded composite repairs for structural health monitoring design

    NASA Astrophysics Data System (ADS)

    Baker, Wayne; Jones, Rhys; Davis, Claire; Galea, Stephen C.

    2002-11-01

    The economic implication of fleet upgrades, particularly in Australia with military aircraft such as the F-111 and F/A-18, has led to an increasing reliance on composite repair technology to address fatigue and corrosion-affected aircraft components. The increasing use of such repairs has led to a research effort to develop various in-situ health monitoring systems that may be incorporated with a repair. This paper reports on the development of a theoretical methodology that uses finite element analysis (FEA) to model the strain profiles which optical sensors, on or within the patch, will be exposed to under various operational scenarios, including load and disbond. Numerical techniques are then used to predict the fibre Bragg grating (FBG) reflections which occur with these strain profiles. The quality of these reflection are a key consideration when designing FBG based structural health monitoring (SHM) systems. This information can be used to optimise the location of both surface mounted, and embedded sensors, and determine feasibility of SHM system design. Research was conducted into the thermal residual strain (TRS) within the patch. A finite element study revealed the presence of significant thermal residual strain gradients along the surface of the tapered region of the patch. As Bragg gratings are particularly sensitive to strain gradients, (producing a result similar to a chirped grating) the strain gradient on the composite at potential sensor locations both under load, and in the event of disbond was considered. A sufficiently high gradient leads to an altered Bragg reflection. These spurious reflections need to be considered, and theoretically obtained reflections can provide information to allow for load scenarios where the Bragg shift is not a smooth, well defined peak. It can also be shown that embedded fibres offer a higher average thermal residual strain reading, while being subject to a much lower strain gradient. This particularly favors the optical disbond detection system that is being developed. While certification concerns exist with embedding sensors in repairs, this study shows that embedded optical fibre sensors may provide for a health monitoring system with enhanced reliability and sensitivity.

  10. Patch-augmented rotator cuff repair: influence of the patch fixation technique on primary biomechanical stability.

    PubMed

    Jung, Christian; Spreiter, Gregor; Audigé, Laurent; Ferguson, Stephen J; Flury, Matthias

    2016-05-01

    There is an ongoing debate about the potential of patch augmentation to improve biomechanical stability and healing associated with rotator cuff repair. The biomechanical properties of three different patch-augmented rotator cuff repair techniques were assessed in vitro and compared with a standard repair. Dermal collagen patch augmentation may increase the primary stability and strength of the repaired tendon in vitro, depending on the technique used for patch application. Forty cadaveric sheep shoulders with dissected infraspinatus tendons were randomized into four groups (n = 10/group) for tendon repair using a knotless double-row suture anchor technique. A xenologous dermal extracellular matrix patch was used for augmentation in the three test groups using an "integrated", "cover", or "hybrid" technique. Tendons were preconditioned, cyclically loaded from 10 to 30 N at 1 Hz, and then loaded monotonically to failure. Biomechanical properties and the mode of failure were evaluated. Patch augmentation significantly increased the maximum load at failure by 61 % in the "cover" technique test group (225.8 N) and 51 % in the "hybrid" technique test group (211.4 N) compared with the non-augmented control group (140.2 N) (P ≤ 0.015). For the test group with "integrated" patch augmentation, the load at failure was 28 % lower (101.6 N) compared with the control group (P = 0.043). There was no significant difference in initial and linear stiffness among the four experimental groups. The most common mode of failure was tendon pullout. No anchor dislocation, patch disruption or knot breakage was observed. Additional patch augmentation with a collagen patch influences the biomechanical properties of a rotator cuff repair in a cadaveric sheep model. Primary repair stability can be significantly improved depending on the augmentation technique.

  11. Aortic valve repair with autologous pericardial patch.

    PubMed

    Lausberg, Henning F; Aicher, Diana; Langer, Frank; Schäfers, Hans-Joachim

    2006-08-01

    Isolated aortic valve repair (AVR) has been gaining increasing interest in recent times. Results of isolated aortic valve repair have been reported to be variable. Various techniques have been utilized. We analyzed our experience with isolated valve repair using autologous pericardial patch plasty and compared the results to an age-matched collective with aortic valve repair without the use of additional material. Between January 1997 and June 2005, pericardial patch plasty of the aortic valve was performed in 42 patients (PATCH). During the same period, 42 patients after AVR without the use of additional material were age matched (NO-PATCH). Mean age in both groups was 52 years with a majority of male patients (PATCH ratio, 3.7:1; NO-PATCH ratio, 5:1). Valve anatomy was similar in both groups. All patients were followed by echocardiography for a cumulative follow-up of 2341 patient months (mean 28+/-23 months). No patient died in the hospital in neither group. The average systolic gradient was 5.9+/-2.2 mmHg in PATCH and 4.8+/-2.1 mmHg in NO-PATCH; p=0.17). Freedom from aortic regurgitation > or = II degrees was 87.8% in PATCH and 95.0% in NO-PATCH after 5 years (p=0.21). Freedom from reoperation was 97.6% in PATCH and 97.4% in NO-PATCH (p=0.96). Aortic regurgitation can be treated effectively by aortic valve repair using pericardial patch plasty. The functional results are satisfactory. With the application of this technique also more complex pathologies of the aortic valve can be addressed adequately thus extending the concept of valve preservation in patients with aortic regurgitation.

  12. Dynamic Analysis with Fibre Optic Sensors for Structural Health Monitoring

    DTIC Science & Technology

    2006-10-01

    cracked thick aluminum plate repaired with a bonded composite patch using transmission-type extrinsic Fabry – Perot interferometric optical fiber...and optical filtering have been used to demodulate returned Bragg signals. Due to the passive nature of the interrogation unit, system bandwidth is

  13. Compressive strength of damaged and repaired composite plates

    NASA Technical Reports Server (NTRS)

    Finn, Scott R.; He, Yi-Fei; Springer, George S.; Lee, Hung-Joo

    1992-01-01

    Tests were performed assessing the effectiveness of repair in restoring the mechanical properties of damaged, solid composite plates made either of Fiberite T300/976 graphite-epoxy, Fiberite IM7/977-2 graphite-toughened epoxy, or ICI APC-2 graphite-PEEK. The plate length, the layup and the amount of damage were also varied. Damage was introduced in the plates either by impacting them with a solid projectile or by applying a transverse static load. Some (75 percent) or all (100 percent) of the damaged zone was then cut out, and the plate was repaired by plugging and patching the hole. The effectiveness of the repair was evaluated by measuring the compressive strengths of undamaged plates, damaged plates with no cutout, damaged plates with a cutout, and repaired plates. The data at an intermediate stage of repair provide information on the effect of each repair step on the compressive strength. The results indicated that for the solid plates used in these tests, the repair methods used herein did not improve the compressive strength of already damaged plates.

  14. Reduction of Moisture Effects During the Cure of Epoxy Adhesives Used in Composite Repair

    NASA Technical Reports Server (NTRS)

    Augl, J. M.; Sivy, G. T.

    1985-01-01

    The requirements for repair work on Naval aircraft composite wing skins that can be performed under depot conditions (or still worse, under field conditions) are quite restrictive. Equipment that can be used is rather limited as are the available repair space and time. The procedures must be simple enough so that they can be performed satisfactorily by personnel without special knowledge in composite materials technology. Repairs of small holes should not require more than perhaps a short predrying cycle (with heat guns) and a subsequent patch bonding using a heating blanket, held in place by applying a vacuum. However, it has been observed during simulated experimental repair work that the glue lines frequently show a high content of pores and bubbles which are attributed to evaporation of moisture during the curing cycle. (Of course, other volatile materials such as residual solvent would act similarly). The purpose of this paper is to give some detailed analysis of the problem of moisture transport as a function of repair conditions, and to discuss some preliminary work to reduce the effect of moisture by removing moisture chemically with carbodiimides before it reaches a critical level for bubble formations.

  15. Corrosion/Degradation Monitoring Technology for Composite Materials used to Extend Building Service Life

    DTIC Science & Technology

    2014-07-01

    for patching concrete structures that have corroded reinforcing steel , but the Army largely avoids structural composite repair applications because...J. Dunmire (OUSD(AT&L)), Bernie Rodriguez (IMPW-FM), and Valerie D. Hines (DAIM-ODF). The work was performed by the Engineering and Materials...buildings in the Army inventory often have se- verely corroded reinforcing steel that necessitates structural upgrades for conformance to current safety

  16. Patch-Augmented Latissimus Dorsi Transfer and Open Reduction–Internal Fixation of Unstable Os Acromiale for Irreparable Massive Posterosuperior Rotator Cuff Tear

    PubMed Central

    Petri, Maximilian; Greenspoon, Joshua A.; Bhatia, Sanjeev; Millett, Peter J.

    2015-01-01

    Latissimus dorsi transfer is a reasonable treatment option for massive posterosuperior rotator cuff tears that can substantially improve chronically painful and dysfunctional shoulders. This report and accompanying video describe the treatment of an active 43-year-old man with severe pain and weakness in the right shoulder after 3 failed rotator cuff repairs. Preoperative imaging showed a massive posterosuperior rotator cuff tear retracted to the glenoid as well as a hypermobile os acromiale likely causing dynamic impingement and recurrent rotator cuff tears. After diagnostic arthroscopy, the latissimus tendon is harvested and augmented with a 3-mm human acellular dermal patch (ArthroFlex; Arthrex, Naples, FL). The native rotator cuff tissue is repaired as much as possible, and the latissimus tendon is passed underneath the deltoid and posterior to the teres minor. The patch-augmented tendon is then integrated into a double-row SpeedBridge repair of eight 4.75-mm BioComposite SwiveLock anchors (Arthrex). The bony surface of the os acromiale is prepared and then fixed to the acromion with 2 cannulated partially threaded screws and additional tension-band wiring. Postoperative rehabilitation initially focuses on early passive range of motion, followed by active and active-assisted motion and a biofeedback program starting at 6 weeks postoperatively. PMID:26697309

  17. Investigation on laser-assisted tissue repair with NIR millisecond-long light pulses and Indocyanine Green-biopolymeric patches

    NASA Astrophysics Data System (ADS)

    Matteini, Paolo; Banchelli, Martina; Cottat, Maximilien; Osticioli, Iacopo; de Angelis, Marella; Rossi, Francesca; Pini, Roberto

    2016-03-01

    In previous works a minimally invasive laser-assisted technique for vascular repair was presented. The technique rests on the photothermal adhesion of a biocompatible and bioresorbable patch containing Indocyanine Green that is brought into contact with the site to be repaired. Afterward the use of NIR millisecond-long light pulses generates a strong welding effect between the patch and the underlying tissue and in turn the repair of the wound. This technique was shown to be effective in animal model and provides several advantages over conventional suturing methods. Here we investigate and discuss the optical stability of the ICG-biopolymeric patches and the photothermal effects induced to the irradiated tissue.

  18. The whole truth: comparative analysis of diaphragmatic hernia repair using 4-ply vs 8-ply small intestinal submucosa in a growing animal model.

    PubMed

    Sandoval, John A; Lou, Derek; Engum, Scott A; Fisher, Lisa M; Bouchard, Christine M; Davis, Mary M; Grosfeld, Jay L

    2006-03-01

    Diaphragmatic reconstruction remains a challenging problem. There is limited information concerning the use of small intestinal submucosa (SIS) in congenital diaphragmatic hernia repair. A canine model was used to evaluate the use of a SIS patch in diaphragmatic reconstruction. Eleven beagle puppies (1.6-4.2 kg, 8 weeks old) underwent left subcostal laparotomy, central left hemidiaphragm excision (2 x 7 cm, 50% loss), and reconstruction with a 4-ply group I (n = 5) or 8-ply group II (n = 6) SIS patch. Chest radiographs were taken at time of operation and 3 and 6 months postoperatively. Animals were killed at 6 months. Adhesion formation (both pleural and abdominal), gross visual evaluation of the patch, and histology were compared. In group I (4-ply), 1 animal died at 3 months from patch deterioration accompanied by stomach herniation that resulted in respiratory failure. In the 4 remaining animals, chest radiographs showed no evidence of herniation or eventration. On physical examination, there was no evidence of chest wall deformity. During gross surgical examination, the 4-ply patches showed thinning, multiple defects, and liver herniation in 3 animals. In 1 pup, the patch was thickened, intact, well incorporated at the repair site, and adherent to the liver and spleen. In group II (8-ply), 1 animal died of cardiopulmonary failure in the early postoperative period. In the other 5 animals, chest radiographs showed evidence of eventration in 1. On gross examination the patch adhered to the liver in all 5 surviving animals. In 4, the patches were thickened, viable, but had some shrinkage. One patch pulled away from the native diaphragm laterally; however, no visceral herniation was present. In the 1 animal with eventration, there was no evidence of a patch. Adhesion scores (AS) were graded and determined by the sum of extent (0-4), type (0-4), and tenacity (0-3). Average abdominal AS in group I was 5.6 +/- 0.8 vs 10.2 +/- 0.2 (P = .079) for group II. Average lung AS was 0.6 +/- 0.6 in group I vs 3.8 +/- 1.1 (P = .0476) for group II. Histological examination showed group II patches had greater collagen deposition with central calcification and mild inflammation within the residual graft, whereas group I patches were much thinner and were composed of granulation tissue without evidence of residual graft. These data indicate that 8-ply SIS repair of diaphragmatic defects was superior (80%; 4/5 to 4-ply, 20%; 1/5, success). Organ adherence appears to be necessary for neovascularization of the SIS composite. Eight-ply grafts appear to be more durable and persist for a longer period, which may improve neovascularization. Long-term follow-up to evaluate remodeling characteristics of the patch material is required.

  19. Application of the bridged crack model for evaluation of materials repairing and self-healing

    NASA Astrophysics Data System (ADS)

    Perelmuter, M.

    2017-12-01

    The bridged crack model is used for analysis of repairing and self-healing of cracked structures. Material repairing is treated as insertions of external ligaments into cracks or placement of the reinforcing patches over cracks. Bonds destruction and regeneration at the crack bridged zone is evaluated by the thermo-fluctuation kinetic theory. The healing time is dependent on the chemical reaction rate of the healing agent, the crack size and the external loads. The decreasing of the stress intensity factors is used as the measure of the repairing and healing effects. The mathematical background of the problem solution is based on the methods of the singular integral-differential equations. The model can be used for the evaluation of composite materials durability.

  20. Comparison of shrinkage related properties of various patch repair materials

    NASA Astrophysics Data System (ADS)

    Kristiawan, S. A.; Fitrianto, R. S.

    2017-02-01

    A patch repair material has been developed in the form of unsaturated polyester resin (UPR)-mortar. The performance and durability of this material are governed by its compatibility with the concrete being repaired. One of the compatibility issue that should be tackled is the dimensional compatibility as a result of differential shrinkage between the repair material and the concrete substrate. This research aims to evaluate such shrinkage related properties of UPR-mortar and to compare with those of other patch repair materials. The investigation includes the following aspects: free shrinkage, resistance to delamination and cracking. The results indicate that UPR-mortar poses a lower free shrinkage, lower risk of both delamination and cracking tendency in comparison to other repair materials.

  1. Cusp repair in aortic valve reconstruction: does the technique affect stability?

    PubMed

    Aicher, Diana; Langer, Frank; Adam, Oliver; Tscholl, Dietmar; Lausberg, Henning; Schäfers, Hans-Joachim

    2007-12-01

    Cusp prolapse may be an isolated cause of aortic regurgitation or may exist in conjunction with dilatation of the proximal aorta. Prolapse can be corrected by central plication, triangular resection, or pericardial patch implantation. We retrospectively analyzed our results with these techniques. From October 1995 to December 2006, 604 patients (aged 3-86 years) underwent aortic valve repair. Cusp prolapse was found in 427 patients (246 tricuspid, 181 bicuspid). Prolapse was corrected by central plication (n = 275) or triangular resection (n = 80). A pericardial patch was implanted for pre-existing cusp defects or after excision of calcium (n = 72). One cusp was repaired in 198 patients; the remaining patients underwent repair of 2 (n = 189) or 3 cusps (n = 40). In 102 patients more than one technique was used, and the patients were allocated to the group of the assumedly more complex repair (central plication < triangular resection < pericardial patch plasty). Cumulative follow-up was 1238 patient-years (mean 35 +/- 27 months). Hospital mortality was 2.6% (11/427). Actuarial freedom from aortic regurgitation of grade II or more at 5 years was 92% (central plication), 90% (triangular resection), and 90% (pericardial patch plasty). Thirteen patients were reoperated on, with prolapse as the most common reason for failure (n = 7); 6 underwent re-repair. Freedom from reoperation at 5 years was 95% (central plication), 94% (triangular resection), and 94% (pericardial patch plasty). Freedom from valve replacement at 5 years was 97% (central plication), 99% (triangular resection), and 98% (pericardial patch plasty). In aortic valve repair, cusp prolapse can be treated reliably by central plication. In the presence of more complex disease, triangular resection or pericardial patch plasty may be used without compromising midterm durability.

  2. Development of a self-stressing NiTiNb shape memory alloy (SMA)/fiber reinforced polymer (FRP) patch

    NASA Astrophysics Data System (ADS)

    El-Tahan, M.; Dawood, M.; Song, G.

    2015-06-01

    The objective of this research is to develop a self-stressing patch using a combination of shape memory alloys (SMAs) and fiber reinforced polymer (FRP) composites. Prestressed carbon FRP patches are emerging as a promising alternative to traditional methods to repair cracked steel structures and civil infrastructure. However, prestressing these patches typically requires heavy and complex fixtures, which is impractical in many applications. This paper presents a new approach in which the prestressing force is applied by restraining the shape memory effect of NiTiNb SMA wires. The wires are subsequently embedded in an FRP overlay patch. This method overcomes the practical challenges associated with conventional prestressing. This paper presents the conceptual development of the self-stressing patch with the support of experimental observations. The bond between the SMA wires and the FRP is evaluated using pull-out tests. The paper concludes with an experimental study that evaluates the patch response during activation subsequent monotonic tensile loading. The results demonstrate that the self-stressing patch with NiTiNb SMA is capable of generating a significant prestressing force with minimal tool and labor requirements.

  3. Tank Remote Repair System Conceptual Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kriikku, E.

    2002-12-06

    This document describes two conceptual designs for a Tank Remote Repair System to perform leak site repairs of double shell waste tank walls (Types I, II, III, and IIIA) from the annulus space. The first concept uses a magnetic wall crawler and an epoxy patch system and the second concept uses a magnetic wall crawler and a magnetic patch system. The recommended concept uses the magnetic patch system, since it is simpler to deliver, easier to apply, and has a higher probability of stopping an active leak.

  4. Development of a Remote External Repair Tool for Damaged or Defective Polyethylene Pipe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kenneth H. Green; Willie E. Rochefort; Nick Wannenmacher

    2006-06-30

    Current procedures for repairing polyethylene (PE) gas pipe require excavation, isolation, and removal of the damaged section of pipe followed by fusing a new section of pipe into place. These techniques are costly and very disruptive. An alternative repair method was developed at Timberline Tool with support from Oregon State University (OSU) and funding by the U. S. Department of Energy National Energy Technology Laboratory (DOE/NETL). This project was undertaken to design, develop and test a tool and method for repairing damaged PE pipe remotely and externally in situ without squeezing off the flow of gas, eliminating the need formore » large-scale excavations. Through an iterative design and development approach, a final engineered prototype was developed that utilizes a unique thermo-chemical and mechanical process to apply a permanent external patch to repair small nicks, gouges and punctures under line pressure. The project identified several technical challenges during the design and development process. The repair tool must be capable of being installed under live conditions and operate in an 18-inch keyhole. This would eliminate the need for extensive excavations thus reducing the cost of the repair. Initially, the tool must be able to control the leak by encapsulating the pipe and apply slight pressure at the site of damage. Finally, the repair method must be permanent at typical operating pressures. The overall results of the project have established a permanent external repair method for use on damaged PE gas pipe in a safe and cost-effective manner. The engineered prototype was subjected to comprehensive testing and evaluation to validate the performance. Using the new repair tool, samples of 4-inch PE pipe with simulated damage were successfully repaired under line pressure to the satisfaction of DOE/NETL and the following natural gas companies: Northwest Natural; Sempra Energy, Southwest Gas Corporation, Questar, and Nicor. However, initial results of accelerated age testing on repaired pipe samples showed that the high density polyethylene (HDPE) pipe patch material developed a small crack at the high stress areas surrounding the patched hole within the first 48 hours of hot water testing, indicating that the patch material has a 25-year lifespan. Based on these results, further research is continuing to develop a stronger repair patch for a satisfactory 50-year patch system. Additional tests were also conducted to evaluate whether any of the critical performance properties of the PE pipe were reduced or compromised by the repair technique. This testing validated a satisfactory 50-year patch system for the pipe.« less

  5. Initial Experience and Early Results of Mitral Valve Repair with Cardiocel Pericardial Patch.

    PubMed

    Tomšič, Anton; Bissessar, Daniella D; van Brakel, Thomas J; Marsan, Nina Ajmone; Klautz, Robert J M; Palmen, Meindert

    2018-06-07

    To assess the performance of a tissue engineering process-treated bovine pericardium patch (CardioCel) in the setting of reconstructive mitral valve surgery. Between 3/2014 and 4/2016, 30 patients (57.2±14.3 years, 27% female) underwent mitral valve leaflet repair with a CardioCel patch. Perioperative mortality was 7% (2 patients, non-graft-related). In 28 remaining patients, pre-discharge echocardiography demonstrated good repaired valve function. At a mean follow-up of 1.7±0.9 years, 3 additional deaths occurred (2 due to infective endocarditis, 1 non-cardiac related). On follow-up echocardiography [follow-up time 1.7±0.8 years, available for 26/28 (93%) hospital survivors], recurrent regurgitation was seen in 2 patients (both infective endocarditis) and 1 underwent reoperation (no infection at the level of patch repair was observed). In the remaining patients, the most recent echocardiogram demonstrated ≤mild regurgitation and stable gradients. The thickness and echodensity of the implanted patch on follow-up echocardiograms were comparable with postoperative echocardiograms. Initial results of the CardioCel patch in mitral valve repair surgery are satisfactory. The resistance to infection and late degeneration will need to be assessed in the future. Copyright © 2018. Published by Elsevier Inc.

  6. Critical and subcritical damage monitoring of bonded composite repairs using innovative non-destructive techniques

    NASA Astrophysics Data System (ADS)

    Grammatikos, S. A.; Kordatos, E. Z.; Aggelis, D. G.; Matikas, T. E.; Paipetis, A. S.

    2012-04-01

    Infrared Thermography (IrT) has been shown to be capable of detecting and monitoring service induced damage of repair composite structures. Full-field imaging, along with portability are the primary benefits of the thermographic technique. On-line lock-in thermography has been reported to successfully monitor damage propagation or/and stress concentration in composite coupons, as mechanical stresses in structures induce heat concentration phenomena around flaws. During mechanical fatigue, cyclic loading plays the role of the heating source and this allows for critical and subcritical damage identification and monitoring using thermography. The Electrical Potential Change Technique (EPCT) is a new method for damage identification and monitoring during loading. The measurement of electrical potential changes at specific points of Carbon Fiber Reinforced Polymers (CFRPs) under load are reported to enable the monitoring of strain or/and damage accumulation. Along with the aforementioned techniques Finally, Acoustic Emission (AE) method is well known to provide information about the location and type of damage. Damage accumulation due to cyclic loading imposes differentiation of certain parameters of AE like duration and energy. Within the scope of this study, infrared thermography is employed along with AE and EPCT methods in order to assess the integrity of bonded repair patches on composite substrates and to monitor critical and subcritical damage induced by the mechanical loading. The combined methodologies were effective in identifying damage initiation and propagation of bonded composite repairs.

  7. Experimental study of ASCs combined with POC-PLA patch for the reconstruction of full-thickness chest wall defects.

    PubMed

    Zhang, Yuanzheng; Fang, Shuo; Dai, Jiezhi; Zhu, Lei; Fan, Hao; Tang, Weiya; Fan, Yongjie; Dai, Haiying; Zhang, Peipei; Wang, Ying; Xing, Xin; Yang, Chao

    2017-01-01

    To explore the repairing effect of combination of adipose stem cells (ASCs) and composite scaffolds on CWR, the electrospun Poly 1, 8-octanediol-co-citric acid (POC)-poly-L-lactide acid (PLA) composite scaffolds were prepared, followed by in vitro and in vivo biocompatibility evaluation of the scaffolds. Afterwards, ASCs were seeded on POC-PLA to construct the POC-PLA-ASCs scaffolds, and the POC-PLA, POC-PLA-ASCs, and traditional materials expanded polytetrafluoroethylene (ePTFE) were adopt for CWR in New Zealand white (NZW) rabbit models. As results, the POC-PLA-ASCs patches possessed good biocompatibility as the high proliferation ability of cells surrounding the patches. Rabbits in POC-PLA-ASCs groups showed better pulmonary function, less pleural adhesion, higher degradation rate and more neovascularization when compared with that in other two groups. The results of western blot indicated that POC-PLA-ASCs patches accelerated the expression of VEGF and Collagen I in rabbit models. From the above, our present study demonstrated that POC-PLA material was applied for CWR successfully, and ASCs seeded on the sheets could improve the pleural adhesions and promote the reparation of chest wall defects.

  8. Portable Holographic Interferometry Testing System: Application to crack patching quality control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heslehurst, R.B.; Baird, J.P.; Williamson, H.M.

    Over recent years the repair of metallic structures has been improved through the use of patches fabricated from composite materials and adhesively bonded to the damaged area. This technology is termed crack patching, and has been successfully and extensively used by the RAAF and the USAF. However, application of the technology to civilian registered aircraft has had limited success due to the apparent lack of suitable quality assurance testing methods and the airworthiness regulators concern overpatch adhesion integrity. Holographic interferometry has previously shown the advantages of detecting out-of-plane deformations of the order of the wavelength of light (1{mu}). Evidence willmore » be presented that holography is able to detect changes in load path due to debonds and weakened adhesion in an adhesively bonded patch. A Portable Holographic Interferometry Testing System (PHITS) which overcomes the vibration isolation problem associated with conventional holography techniques has been developed. The application of PHITS to crack patching technology now provides a suitable method to verify the integrity of bonded patches in-situ.« less

  9. The Usefulness of Patch Repair Using the Repermeabilized Umbilical Vein of the Round Ligament for Hepatobiliary Malignancies.

    PubMed

    Takahashi, Michiro; Saiura, Akio; Takahashi, Yu

    2017-11-01

    Patients with tumors invading major veins may require combined resection and reconstruction. However, venous reconstruction often demands complex hepatobiliary and vascular surgical procedures. In this study, we report a simple patch repair technique for venous reconstruction using the repermeabilized umbilical vein of the round ligament. We reviewed the outcomes of eleven patients who underwent venous wedge resection and patch repair using the repermeabilized umbilical vein of the round ligament at our institution. Procurement of the round ligament and method of making a patch is simple. The duration of anastomosis was approximately 15 min. Eight patients (73%) underwent hepatic resection followed by hepatic vein reconstruction; two (18%) pancreaticoduodenectomy followed by inferior vena cava (IVC) reconstruction; one (9%) hepatic resection followed by IVC reconstruction. Although one reconstructed vein became narrowed, the other ten veins were patent after surgery. Patch repair using the repermeabilized umbilical vein of the round ligament is a simple and useful technique.

  10. Stability of double-row rotator cuff repair is not adversely affected by scaffold interposition between tendon and bone.

    PubMed

    Beitzel, Knut; Chowaniec, David M; McCarthy, Mary Beth; Cote, Mark P; Russell, Ryan P; Obopilwe, Elifho; Imhoff, Andreas B; Arciero, Robert A; Mazzocca, Augustus D

    2012-05-01

    Rotator cuff reconstructions may be improved by adding growth factors, cells, or other biologic factors into the repair zone. This usually requires a biological carrier (scaffold) to be integrated into the construct and placed in the area of tendon-to-bone healing. This needs to be done without affecting the constructs mechanics. Hypothesis/ The hypothesis was that scaffold placement, as an interposition, has no adverse effects on biomechanical properties of double-row rotator cuff repair. The purpose of this study was to examine the effect of scaffold interposition on the initial strength of rotator cuff repairs. Controlled laboratory study. Twenty-five fresh-frozen shoulders (mean age: 65.5 ± 8.9 years) were randomly assigned to 5 groups. Groups were chosen to represent a broad spectrum of commonly used scaffold types: (1) double-row repair without augmentation, (2) double-row repair with interposition of a fibrin clot (Viscogel), (3) double-row repair with interposition of a collagen scaffold (Mucograft) between tendon and bone, (4) double-row repair with interposition of human dermis patch (ArthroFlex) between tendon and bone, and (5) double-row repair with human dermis patch (ArthroFlex) placed on top of the repair. Cyclic loading to measure displacement was performed to 3000 cycles at 1 Hz with an applied 10- to 100-N load. The ultimate load to failure was determined at a rate of 31 mm/min. There were no significant differences in mean displacement under cyclic loading, slope, or energy absorbed to failure between all groups (P = .128, P = .981, P = .105). Ultimate load to failure of repairs that used the collagen patch as an interposition (573.3 ± 75.6 N) and a dermis patch on top of the reconstruction (575.8 ± 22.6 N) was higher compared with the repair without a scaffold (348.9 ± 98.8 N; P = .018 and P = .025). No significant differences were found for repairs with the fibrin clot as an interposition (426.9 ± 103.6 N) and the decellularized dermis patch as an interposition (469.9 ± 148.6 N; P = .73 and P = .35). Scaffold augmentation did not adversely affect the zero time strength of the tested standard double-row rotator cuff repairs. An increased ultimate load to failure was observed for 2 of the augmentation methods (collagen patch as an interposition and decellularized dermis patch on top of the reconstruction) compared with the nonaugmented repairs. Scaffolds intended for application of growth factors or cellular components in a repair situation did not adversely jeopardize the stability of the operative construct.

  11. Laparoscopic repair of perforated peptic ulcer-technical tip.

    PubMed

    Jayanthi, Naga Venkatesh Gupta

    2013-08-01

    Increasing number of gastrointestinal emergencies are managed laparoscopically. Laparoscopic repair of a perforated peptic ulcer remains contentious. Fashioning an omental patch is a crucial and an essential part of this repair, whether it is performed open or laparoscopically. This article describes a technique to fashion an adequate omental patch over the perforated peptic ulcer.

  12. Occupational Contact Dermatitis in Mechanics and Repairers Referred for Patch Testing: Retrospective Analysis From the North American Contact Dermatitis Group 1998-2014.

    PubMed

    Warshaw, Erin M; Hagen, Solveig L; Sasseville, Denis; Maibach, Howard I; DeKoven, Joel G; Belsito, Donald V; Fowler, Joseph F; Zug, Kathryn A; Taylor, James S; Mathias, C G Toby; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Zirwas, Matthew J; Storrs, Frances J

    Contact dermatoses are common in mechanic and repair occupations. This study aimed to (1) estimate the prevalence of occupationally related contact dermatitis among mechanics/repairers patch tested from 1998 to 2014 by the North American Contact Dermatitis Group, (2) characterize responsible allergens and irritants, and their sources, and (3) compare results among 3 occupational subgroups (mechanics, electrical/electronic, and other). A cross-sectional analysis of patients patch tested by the North American Contact Dermatitis Group between 1998 and 2014. Of 38,784 patients patch tested, 691 (1.8%) were mechanics/repairers. Male sex (93.5%) and hand involvement (59.5%) were common overall. Occupationally related skin disease was more prevalent among vehicle and mobile equipment mechanics/repairers (52.7%) and other mechanics/repairers (41.4%) than electrical/electronic equipment mechanics/repairers (21.3%). Overall, carba mix, thiuram mix, and methylchloroisothiazolone/methylisothiazolone were the most common occupation-related clinically relevant allergens. Gloves, automotive vehicles, solvents, oils, lubricants, and fuels were the most common sources of responsible allergens. Common occupationally related allergens included rubber accelerators and the preservative methylchloroisothiazolone/methylisothiazolone.

  13. Use of composite materials, health monitoring and self-healing concepts to refurbish our civil and military infrastructure.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roach, Dennis Patrick; Delong, Waylon Anthony; White, Scott

    An unavoidable by-product of a metallic structure's use is the appearance of crack, corrosion, erosion and other flaws. Economic barriers to the replacement of these structures have created an aging civil and military infrastructure and placed even greater demands on efficient and safe repair and inspection methods. As a result of Homeland Security issues and these aging infrastructure concerns, increased attention has been focused on the rapid repair and preemptive reinforcement of structures such as buildings and bridges. This Laboratory Directed Research and Development (LDRD) program established the viability of using bonded composite patches to repair metallic structures. High modulusmore » fiber-reinforced polymer (FRP) material may be used in lieu of mechanically fastened metallic patches or welds to reinforce or repair damaged structures. Their use produces a wide array of engineering and economic advantages. Current techniques for strengthening steel structures have several drawbacks including requiring heavy equipment for installation, poor fatigue performance, and the need for ongoing maintenance due to continued corrosion attack or crack growth. The use of bonded composite doublers has the potential to correct the difficulties associated with current repair techniques and the ability to be applied where there are currently no rehabilitation options. Applications include such diverse structures as: buildings, bridges, railroad cars, trucks and other heavy machinery, steel power and communication towers, pipelines, factories, mining equipment, ships, tanks and other military vehicles. This LDRD also proved the concept of a living infrastructure by developing custom sensors and self-healing chemistry and linking this technology with the application of advanced composite materials. Structural Health Monitoring (SHM) systems and mountable, miniature sensors were designed to continuously or periodically assess structural integrity. Such systems are able to detect incipient damage before catastrophic failure occurs. The ease of monitoring an entire network of distributed sensors means that structural health assessments can occur more often, allowing operators to be even more vigilant with respect to flaw onset. In addition, the realization of smart structures, through the use of in-situ sensors, allows condition-based maintenance to be substituted for conventional time-based maintenance practices. The sensitivity and reliability of a series of sensor systems was quantified in laboratory and real-world environments. Finally, self healing methods for composite materials were evolved--using resin modules that are released in response to the onset of delaminations--so that these components can provide a living infrastructure with minimal need for human intervention. This program consisted of four related research elements: (1) design, installation, and performance assessment of composite repairs, (2) in-situ sensors for real-time health monitoring, (3) self healing of in-service damage in a repair, and (4) numerical modeling. Deployment of FRP materials and bonded joints requires proper design, suitable surface preparation methods, and adequate surveillance to ensure structural integrity. By encompassing all 'cradle-to-grave' tasks --including design, analysis, installation, durability, flaw containment, and inspection--this program is designed to firmly establish the capabilities of composite doubler repairs and introduce technology to incorporate self-monitoring and self-healing (living structures) methodologies. A proof-of-concept repair was completed on a steel highway bridge in order to demonstrate the potential of composite doubler technology for critical infrastructure use.« less

  14. Damage tolerance of bonded composite aircraft repairs for metallic structures

    NASA Astrophysics Data System (ADS)

    Clark, Randal John

    This thesis describes the development and validation of methods for damage tolerance substantiation of bonded composite repairs applied to cracked plates. This technology is used to repair metal aircraft structures, offering improvements in fatigue life, cost, manufacturability, and inspectability when compared to riveted repairs. The work focuses on the effects of plate thickness and bending on repair life, and covers fundamental aspects of fracture and fatigue of cracked plates and bonded joints. This project falls under the UBC Bonded Composite Repair Program, which has the goal of certification and widespread use of bonded repairs in civilian air transportation. This thesis analyses the plate thickness and transverse stress effects on fracture of repaired plates and the related problem of induced geometrically nonlinear bending in unbalanced (single-sided) repairs. The author begins by developing a classification scheme for assigning repair damage tolerance substantiation requirements based upon stress-based adhesive fracture/fatigue criteria and the residual strength of the original structure. The governing equations for bending of cracked plates are then reformulated and line-spring models are developed for linear and nonlinear coupled bending and extension of reinforced cracks. The line-spring models were used to correct the Wang and Rose energy method for the determination of the long-crack limit stress intensity, and to develop a new interpolation model for repaired cracks of arbitrary length. The analysis was validated using finite element models and data from mechanical tests performed on hybrid bonded joints and repair specimens that are representative of an in-service repair. This work will allow designers to evaluate the damage tolerance of the repaired plate, the adhesive, and the composite patch, which is an airworthiness requirement under FAR (Federal Aviation Regulations) 25.571. The thesis concludes by assessing the remaining barriers to certification of bonded repairs, discussing the results of the analysis, and making suggestions for future work. The developed techniques should also prove to be useful for the analysis of fibre-reinforced metal laminates and other layered structures. Some concepts are general and should be useful in the analysis of any plate with large in-plane stress gradients that lead to significant transverse stresses.

  15. An electrospun polydioxanone patch for the localisation of biological therapies during tendon repair.

    PubMed

    Hakimi, O; Murphy, R; Stachewicz, U; Hislop, S; Carr, A J

    2012-10-23

    Rotator cuff tendon pathology is thought to account for 30-70 % of all shoulder pain. For cases that have failed conservative treatment, surgical re-attachment of the tendon to the bone with a non-absorbable suture is a common option. However, the failure rate of these repairs is high, estimated at up to 75 %. Studies have shown that in late disease stages the tendon itself is extremely degenerate, with reduced cell numbers and poor matrix organisation. Thus, it has been suggested that adding biological factors such as platelet rich plasma (PRP) and mesenchymal stem cells could improve healing. However, the articular capsule of the glenohumeral joint and the subacromial bursa are large spaces, and injecting beneficial factors into these sites does not ensure localisation to the area of tendon damage. Thus, the aim of this study was to develop a biocompatible patch for improving the healing rates of rotator cuff repairs. The patch will create a confinement around the repair area and will be used to guide injections to the vicinity of the surgical repair. Here, we characterised and tested a preliminary prototype of the patch utilising in vitro tools and primary tendon-derived cells, showing exceptional biocompatibility despite rapid degradation, improved cell attachment and that cells could migrate across the patch towards a chemo-attractant. Finally, we showed the feasibility of detecting the patch using ultrasound and injecting liquid into the confinement ex vivo. There is a potential for using this scaffold in the surgical repair of interfaces such as the tendon insertion in the rotator cuff, in conjunction with beneficial factors.

  16. The Effects of Platelet-Rich Plasma on Bone Marrow Stromal Cell Transplants for Tendon Healing In Vitro

    PubMed Central

    Morizaki, Yutaka; Zhao, Chunfeng; An, Kai-Nan; Amadio, Peter C.

    2010-01-01

    Purpose In this study we investigated the effect of platelet-rich plasma (PRP) and bone-marrow derived stromal cell (BMSC)-seeded interposition in an in vitro canine tendon repair model. Methods Bone marrow, peripheral blood, and tendons were harvested from mixed breed dogs. BMSC were cultured and passaged from adherent cells of bone marrow suspension. PRP was purified from peripheral blood using a commercial kit. 192 flexor digitorum profundus tendons were used for the study. Tendons repaired with a simple suture were used as a control group. In treatment groups, a collagen gel patch was interposed at the tendon repair site prior to suture. There were three treatment groups according to the type of collagen patch; a patch with PRP, a patch with BMSC, and a patch with PRP and BMSC. The repaired tendons were evaluated by biomechanical testing and by histological survey after 2 and 4 weeks in tissue culture. To evaluate viability, cells were labeled with PKH26 and surveyed under confocal microscopy after culture. Results The maximum breaking strength and stiffness of the healing tendons with the BMSC-seeded PRP patch was significantly higher than the healing tendons without a patch or with a cell-seeded patch (p<0.02). Viable BMSC were present at both 2 and 4 weeks. Conclusions PRP enhanced the effect of BMSC-seeded collagen gel interposition in this in vitro model. Based on these results we now plan to investigate this effect in vivo. PMID:20951509

  17. In-Space Repair of Reinforced Carbon-Carbon (RCC) Thermal Protection System Structures

    NASA Technical Reports Server (NTRS)

    Singh, Mrityunjay

    2005-01-01

    Advanced repair and refurbishment technologies are critically needed for the RCC-based thermal protection system of current space transportation system as well as for future Crew Exploration Vehicles (CEV). The damage to these components could be caused by impact during ground handling or due to falling of ice or other objects during launch. In addition, in-orbit damage includes micrometeoroid and orbital debris impact as well as different factors (weather, launch acoustics, shearing, etc.) during launch and re-entry. The GRC developed GRABER (Glenn Refractory Adhesive for Bonding and Exterior Repair) material has shown multiuse capability for repair of small cracks and damage in reinforced carbon-carbon (RCC) material. The concept consists of preparing an adhesive paste of desired ceramic with appropriate adhesives and then applying the paste to the damaged/cracked area of the RCC composites with adhesive delivery system. The adhesive paste cures at 100-120 C and transforms into a high temperature ceramic during simulated entry conditions. A number of plasma torch and ArcJet tests were carried out to evaluate the crack repair capability of GRABER materials for Reinforced Carbon-Carbon (RCC) composites. For the large area repair applications, PLASTER (Patch Laminates and Sealant Technology for Exterior Repair) based systems have been developed. In this presentation, critical in-space repair needs and technical challenges as well as various issues and complexities will be discussed along with the plasma performance and post test characterization of repaired RCC materials.

  18. On structural health monitoring of aircraft adhesively bonded repairs

    NASA Astrophysics Data System (ADS)

    Pavlopoulou, Sofia

    The recent interest in life extension of ageing aircraft and the need to address the repair challenges in the new age composite ones, led to the investigation of new repair methodologies such as adhesively bonded repair patches. The present thesis focuses on structural health monitoring aspects of the repairs, evaluating their performance with guided ultrasonic waves aiming to develop a monitoring strategy which would eliminate unscheduled maintenance and unnecessary inspection costs. To address the complex nature of the wave propagation phenomena, a finite element based model identified the existing challenges by exploring the interaction of the excitation waves with different levels of damage. The damage sensitivity of the first anti-symmetric mode was numerically investigated. An external bonded patch and a scarf repair, were further tested in static and dynamic loadings, and their performance was monitored with Lamb waves, excited by surface-bonded piezoelectric transducers.. The response was processed by means of advanced pattern recognition and data dimension reduction techniques such as novelty detection and principal component analysis. An optimisation of these tools enabled an accurate damage detection under complex conditions. The phenomena of mode isolation and precise arrival time determination under a noisy environment and the problem of inadequate training data were investigated and solved through appropriate transducer arrangements and advanced signal processing respectively. The applicability of the established techniques was demonstrated on an aluminium repaired helicopter tail stabilizer. Each case study utilised alternative non-destructive techniques for validation such as 3D digital image correlation, X-ray radiography and thermography. Finally a feature selection strategy was developed through the analysis of the instantaneous properties of guided waves for damage detection purposes..

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roach, Dennis Patrick; Rackow, Kirk A.

    A typical aircraft can experience over 2,000 fatigue cycles (cabin pressurizations) and even greater flight hours in a single year. An unavoidable by-product of aircraft use is that crack, impact, and corrosion flaws develop throughout the aircraft's skin and substructure elements. Economic barriers to the purchase of new aircraft have placed even greater demands on efficient and safe repair methods. The use of bonded composite doublers offers the airframe manufacturers and aircraft maintenance facilities a cost effective method to safely extend the lives of their aircraft. Instead of riveting multiple steel or aluminum plates to facilitate an aircraft repair, itmore » is now possible to bond a single Boron-Epoxy composite doubler to the damaged structure. The FAA's Airworthiness Assurance Center at Sandia National Labs (AANC), Boeing, and Federal Express completed a pilot program to validate and introduce composite doubler repair technology to the U.S. commercial aircraft industry. This project focused on repair of DC-10 fuselage structure and its primary goal was to demonstrate routine use of this repair technology using niche applications that streamline the design-to-installation process. As composite doubler repairs gradually appear in the commercial aircraft arena, successful flight operation data is being accumulated. These commercial aircraft repairs are not only demonstrating the engineering and economic advantages of composite doubler technology but they are also establishing the ability of commercial maintenance depots to safely adopt this repair technique. This report presents the array of engineering activities that were completed in order to make this technology available for widespread commercial aircraft use. Focused laboratory testing was conducted to compliment the field data and to address specific issues regarding damage tolerance and flaw growth in composite doubler repairs. Fatigue and strength tests were performed on a simulated wing repair using a substandard design and a flawed installation. In addition, the new Sol-Gel surface preparation technique was evaluated. Fatigue coupon tests produced Sol-Gel results that could be compared with a large performance database from conventional, riveted repairs. It was demonstrated that not only can composite doublers perform well in severe off-design conditions (low doubler stiffness and presence of defects in doubler installation) but that the Sol-Gel surface preparation technique is easier and quicker to carry out while still producing optimum bonding properties. Nondestructive inspection (NDI) methods were developed so that the potential for disbond and delamination growth could be monitored and crack growth mitigation could be quantified. The NDI methods were validated using full-scale test articles and the FedEx aircraft installations. It was demonstrated that specialized NDI techniques can detect flaws in composite doubler installations before they reach critical size. Probability of Detection studies were integrated into the FedEx training in order to quantify the ability of aircraft maintenance depots to properly monitor these repairs. In addition, Boeing Structural Repair and Nondestructive Testing Manuals were modified to include composite doubler repair and inspection procedures. This report presents the results from the FedEx Pilot Program that involved installation and surveillance of numerous repairs on operating aircraft. Results from critical NDI evaluations are reported in light of damage tolerance assessments for bonded composite doublers. This work has produced significant interest from airlines and aircraft manufacturers. The successful Pilot Program produced flight performance history to establish the durability of bonded composite patches as a permanent repair on commercial aircraft structures. This report discusses both the laboratory data and Pilot Program results from repair installations on operating aircraft to introduce composite doubler repairs into mainstream commercial aircraft use.« less

  20. Concomitant abdominoplasty and umbilical hernia repair using the Ventralex hernia patch.

    PubMed

    Neinstein, Ryan M; Matarasso, Alan; Abramson, David L

    2015-04-01

    Patients requesting abdominoplasty often have concomitant umbilical hernias and may request simultaneous treatment. The vascularity of the umbilicus is potentially at risk during these combined procedures. In this study, the authors present a technique for treating umbilical hernias at the time of abdominoplasty surgery using the Ventralex hernia patch. A total of 11 female patients with a mean age of 39.4 years (range, 28 to 51 years) undergoing abdominoplasty with umbilical hernia repair with the Ventralex patch were included. The mean body mass index was 27.6 kg/m (range, 20 to 34 kg/m). No vascular compromise of the umbilicus was seen. The hernia repair did not alter the abdominoplasty results. One patient had transient umbilical swelling postoperatively that resolved within 6 months postoperatively. The authors present a series of umbilical hernia repairs in abdominoplasty patients using a minimal access incision by means of the rectus fascia and the Ventralex patch that is fast and reliable and preserves the blood supply to the umbilicus.

  1. Experimental evaluation of ileal patch in delayed primary repair of penetrating colon injuries: An animal study.

    PubMed

    Abbasi, Hamid Reza; Bolandparvaz, Shahram; Yarmohammadi, Hooman; Geramizadeh, Bita; Tanideh, Nader; Paydar, Shahram; Hosseini, Seyed Vahid

    2006-10-01

    Primary repair of traumatic colonic perforation is progressively gaining acceptance as the best method of management. However, when delayed, the risk of infection-related complications may increase. Here, we present a new method of repairing colon perforation in the presence of peritonitis. Acute colon injury was simulated in 22 German shepherd dogs. The dogs were randomly divided into two groups of 11 and after 24 hours they were operated on. The perforations were repaired by subserosal suture technique. In the first group (group A), ileal patch was used. In the other group (group B), the colon was closed by debridement and anastomosis. After 6 weeks, the repairs were assessed on the basis of survival, gross and histological assessments. Nine (82%) dogs in group A and six (56%) in group B survived. Ileal patch utilization significantly decreased the mortality rate (p < 0.05). The cause of death in two group A dogs and five group B dogs was peritonitis and intra-abdominal abscess formation. None of the surviving dogs showed evidence of anastomotic leakage or breakdown. Small bowel patch used in primary repair of colon injury in the presence of peritonitis may decrease the risk of postoperative infection-related complications and the mortality rate.

  2. Natural orifice transluminal endoscopic surgery for patients with perforated peptic ulcer.

    PubMed

    Bonin, Eduardo A; Moran, Erica; Gostout, Christopher J; McConico, Andrea L; Zielinski, Martin; Bingener, Juliane

    2012-06-01

    Perforation accounts for 70% of deaths attributed to peptic ulcers. Laparoscopic repair is effective but infrequently used. Our aim was to assess how many patients with perforated peptic ulcer could be candidates for a transluminal endoscopic omental patch closure. This retrospective study reviewed patients with perforated peptic ulcer from 2005 to 2010. Demographics, ulcer characteristics, operative procedure, and outcomes were recorded. Candidates for endoscopic transluminal repair were defined as those having undergone omental patch closure of an ulcer of appropriate size and no contraindications to laparoscopy or endoscopy. In the retrospective review, a total of 104 patients were identified; 62% female, mean age = 68 years, mean ASA of 3, and 63% medication-related ulcers. Fifty-nine (63%) had an omental patch (80% open), and 35 (37%) had other procedures. Ten patients had nonoperative management. Thirty-day mortality was 14% and 1 year mortality was 35%. Forty-nine patients (52%) were considered potential candidates for transluminal repair. Sixty-three percent of our patients sustained a medication-related perforation with 1 year mortality of 35%. The majority of patients were treated using open omental patch repair. Transluminal endoscopic repair may provide an additional situation for a minimally invasive approach for a number of these patients.

  3. Fibrin patch-based insulin-like growth factor-1 gene-modified stem cell transplantation repairs ischemic myocardium.

    PubMed

    Li, Jun; Zhu, Kai; Yang, Shan; Wang, Yulin; Guo, Changfa; Yin, Kanhua; Wang, Chunsheng; Lai, Hao

    2015-05-01

    Bone marrow mesenchymal stem cells (BMSCs), tissue-engineered cardiac patch, and therapeutic gene have all been proposed as promising therapy strategies for cardiac repair after myocardial infarction. In our study, BMSCs were modified with insulin-like growth factor-1 (IGF-1) gene, loaded into a fibrin patch, and then transplanted into a porcine model of ischemia/reperfusion (I/R) myocardium injury. The results demonstrated that IGF-1 gene overexpression could promote proliferation of endothelial cells and cardiomyocyte-like differentiation of BMSCs in vitro. Four weeks after transplantation of fibrin patch loaded with gene-modified BMSCs, IGF-1 overexpression could successfully promote angiogenesis, inhibit remodeling, increase grafted cell survival and reduce apoptosis. In conclusion, the integrated strategy, which combined fibrin patch with IGF-1 gene modified BMSCs, could promote the histological cardiac repair for a clinically relevant porcine model of I/R myocardium injury. © 2015 by the Society for Experimental Biology and Medicine.

  4. A Feasibility Study into the Active Smart Patch Concept for Composite Bonded Repairs

    DTIC Science & Technology

    2008-08-01

    electrical resistance foil gauges and PVDF (polyvinylidene) piezoelectric film to sense the local strain relaxation that occurs in re- sponse to failure of...structural components, like a wing skin, that are ‘thin’ in comparison to the wavelengths of low frequency ultrasound , and therefore act as efficient...region for the respective excitation frequency. The processed experimental data is compared to theoretical dispersion curves for both Lamb waves and

  5. Aeronautical Research Laboratories Structures Division Annual Report 1979-80

    DTIC Science & Technology

    1981-04-01

    8217 :- LLWL 0 > D z cw iLU U Cn C 0 Jojoe ; ou!,sos SSJI 20 12.1.5 Fibre composite patch repair A report has been completea on the design of boron fibre...bl.R.Ae.S., M.I.L.Aust. S.R. Sarrailhe, C.Eng., M.I.Hech.E., M.I.h.Aust. Experimental Officer Class 2 R.P. Carey , B.Hech.E., M.I.E.Aust. R.G. Parker

  6. Catheter enterostomy and patch repair of the abdominal wall for gastroschisis with intestinal atresia: report of a case.

    PubMed

    Ohno, Koichi; Nakamura, Tetsuro; Azuma, Takashi; Yoshida, Tatsuyuki; Yamada, Hiroto; Hayashi, Hiroaki; Masahata, Kazunori

    2009-01-01

    A male infant, weighing 2177 g, was born with the entire intestine protruding through a defect on the right side of the navel. Intestinal atresia, approximately 70 cm from the Treitz ligament, was also confirmed. Primary anastomosis and abdominal wall repair were impossible because of the intestinal dilation and thick peel, as well as the small abdominal cavity. Thus, we initially performed catheter enterostomy with a 14-F balloon catheter and patch repair of the abdominal wall, to enable the baby to be fed. Secondary anastomosis and abdominal wall repair was safely performed when the baby was 106 days old. The combination of catheter enterostomy and patch repair of the abdominal wall does not require dissection of the intestine and it can be safely performed in low-birth-weight babies. It also enables feeding and weight gain, and the overlying skin prevents contamination of the artificial sheet. We recommend this combination for neonates with both gastroschisis and intestinal atresia.

  7. Use of buccal mucosa patch graft for recurrent large urethrocutaneous fistula after hypospadias repair.

    PubMed

    Kiss, András; Pirót, László; Karsza, Levente; Merksz, Miklós

    2004-01-01

    To assess the effectiveness of buccal mucosa patch graft in the treatment of recurrent large urethrocutaneous fistula after hypospadias repair. A free graft of buccal mucosa was used for closure in 7 boys (mean age 4.8 years) with large (>4 mm) urethocutaneous fistula. Four fistulas were in the midshaft, 2 of them penoscrotal and 1 coronal type. All patients had undergone at least two previous unsuccessful fistula repairs, and 3 of them had undergone three attempts for closure. Fistula repairs were similar in all cases. The repair was successful in 6 out of 7 cases, and in these cases the urinary stream was good after the removal of the catheter. The unsuccessful case was the coronal one. Based on our experience it seems that in cases with recurrent large fistula after hypospadias reconstruction, the use of buccal mucosa patch graft for closure is a good treatment choice. Copyright 2004 S. Karger AG, Basel

  8. Molecular biology of Streptococcus pneumoniae: an everlasting challenge.

    PubMed

    Sicard, M; Gasc, A M; Giammarinaro, P; Lefrançois, J; Pasta, F; Samrakandi, M

    2000-01-01

    Streptococcus pneumoniae is a model for elucidating: 1) recombination steps of DNA, from its discovery to polarity of integration; 2) long-patch mismatch repair, short-patch repair triggered by A/G and exclusion of deletions; 3) resistance to beta-lactam antibiotics; and 4) factors of virulence. Several of these topics remain a challenge for future investigations.

  9. Dimer excision in Escherichia coli in the presence of caffeine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rothman, R.H.

    1980-07-01

    The observation that polA1 and recL152 mutations result in both slow pyrimidine dimer excision and large repair patch size leads to the hypothesis that patch size is directly related to the rate of excision. In this study caffeine, a known inhibitor of excision repair, was used to examine the extent of correlation between excision rate and patch size by measuring patch size in the presence of several concentrations of caffeine. Both the rate of excision and the resistance to ultraviolet radiation were reduced with increasing concentrations of caffeine after irradiation. Caffeine also inhibited the rate at which incisions were mademore » and prolonged the time required to rejoin the discontinuities. Patch size, however, was unaffected by caffeine treatment.« less

  10. Expedient Repair Materials for Roadway Pavements

    DTIC Science & Technology

    2005-03-01

    SILSPEC 900 PNS Patch/spall SSI Const. & Indus. Elastomeric conc. Matls Sikadur 22 Lo-Mod Sika Corp. Epoxy polymer concrete SikaTop 123 Plus Thin...patch Sika 2-component, polymer- 15 min modified Sikaset Roadway Patch Patch/spall Sika 1-comp. with high 15-25 min (15 min) (2000) alumina cement (not

  11. INTERNAL REPAIR OF PIPELINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bill Bruce; Nancy Porter; George Ritter

    2005-07-20

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, undermore » congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners, indicating that this type of liner is only marginally effective at restoring the pressure containing capabilities of pipelines. Failure pressures for larger diameter pipe repaired with a semi-circular patch of carbon fiber-reinforced composite lines were also marginally greater than that of a pipe section with un-repaired simulated damage without a liner. These results indicate that fiber reinforced composite liners have the potential to increase the burst pressure of pipe sections with external damage Carbon fiber based liners are viewed as more promising than glass fiber based liners because of the potential for more closely matching the mechanical properties of steel. Pipe repaired with weld deposition failed at pressures lower than that of un-repaired pipe in both the virgin and damaged conditions, indicating that this repair technology is less effective at restoring the pressure containing capability of pipe than a carbon fiber-reinforced liner repair. Physical testing indicates that carbon fiber-reinforced liner repair is the most promising technology evaluated to-date. In lieu of a field installation on an abandoned pipeline, a preliminary nondestructive testing protocol is being developed to determine the success or failure of the fiber-reinforced liner pipeline repairs. Optimization and validation activities for carbon-fiber repair methods are ongoing.« less

  12. Generalized peritonitis requiring re-operation after leakage of omental patch repair of perforated peptic ulcer.

    PubMed

    Maghsoudi, Hemmat; Ghaffari, Alireza

    2011-01-01

    Peptic ulcer perforations are a common emergency, but available literature is silent on the exact definition, incidence, management, and complications of peritonitis due to omental patch leakage. Retrospective data were collected on 422 patients who underwent omental patch repair of perforated peptic ulcer between March 20, 1999 and March 20, 2006. The definitive diagnosis of perforated peptic ulcer and omental patch leakage was obtained at surgery. Seventeen (4%) patients experienced generalized peritonitis due to omental patch leakage. Mean age was 60.6 years. Mortality rate was 29.4%, and the mean hospital stay was 23.6 days. Delay in surgical approach, shock on admission, and age were all significantly associated with increased mortality. Peritonitis due to omental patch leakage can result in significant morbidity and mortality. The most common causes of omental patch leakage and operative procedures were unknown and reinsertion of omentum, respectively. Factors such as shock on admission or delayed surgery, have significantly contributed to fatal outcomes and need careful attention.

  13. INTERNAL REPAIR OF PIPELINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robin Gordon; Bill Bruce; Ian Harris

    2004-12-31

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, undermore » congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners, indicating that this type of liner is only marginally effective at restoring the pressure containing capabilities of pipelines. Failure pressures for larger diameter pipe repaired with a semi-circular patch of carbon fiber-reinforced composite lines were also marginally greater than that of a pipe section with un-repaired simulated damage without a liner. These results indicate that fiber reinforced composite liners have the potential to increase the burst pressure of pipe sections with external damage Carbon fiber based liners are viewed as more promising than glass fiber based liners because of the potential for more closely matching the mechanical properties of steel. Pipe repaired with weld deposition failed at pressures lower than that of un-repaired pipe in both the virgin and damaged conditions, indicating that this repair technology is less effective at restoring the pressure containing capability of pipe than a carbon fiber-reinforced liner repair. Physical testing indicates that carbon fiber-reinforced liner repair is the most promising technology evaluated to-date. The first round of optimization and validation activities for carbon-fiber repairs are complete. Development of a comprehensive test plan for this process is recommended for use in the field trial portion of this program.« less

  14. The effects of platelet lysate patches on the activity of tendon-derived cells.

    PubMed

    Costa-Almeida, Raquel; Franco, Albina R; Pesqueira, Tamagno; Oliveira, Mariana B; Babo, Pedro S; Leonor, Isabel B; Mano, João F; Reis, Rui L; Gomes, Manuela E

    2018-03-01

    Platelet-derived biomaterials are widely explored as cost-effective sources of therapeutic factors, holding a strong potential for endogenous regenerative medicine. Particularly for tendon repair, treatment approaches that shift the injury environment are explored to accelerate tendon regeneration. Herein, genipin-crosslinked platelet lysate (PL) patches are proposed for the delivery of human-derived therapeutic factors in patch augmentation strategies aiming at tendon repair. Developed PL patches exhibited a controlled release profile of PL proteins, including bFGF and PDGF-BB. Additionally, PL patches exhibited an antibacterial effect by preventing the adhesion, proliferation and biofilm formation by S. aureus, a common pathogen in orthopaedic surgical site infections. Furthermore, these patches supported the activity of human tendon-derived cells (hTDCs). Cells were able to proliferate over time and an up-regulation of tenogenic genes (SCX, COL1A1 and TNC) was observed, suggesting that PL patches may modify the behavior of hTDCs. Accordingly, hTDCs deposited tendon-related extracellular matrix proteins, namely collagen type I and tenascin C. In summary, PL patches can act as a reservoir of biomolecules derived from PL and support the activity of native tendon cells, being proposed as bioinstructive patches for tendon regeneration. Platelet-derived biomaterials hold great interest for the delivery of therapeutic factors for applications in endogenous regenerative medicine. In the particular case of tendon repair, patch augmentation strategies aiming at shifting the injury environment are explored to improve tendon regeneration. In this study, PL patches were developed with remarkable features, including the controlled release of growth factors and antibacterial efficacy. Remarkably, PL patches supported the activity of native tendon cells by up-regulating tenogenic genes and enabling the deposition of ECM proteins. This patch holds great potential towards simultaneously reducing post-implantation surgical site infections and promoting tendon regeneration for prospective in vivo applications. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  15. Transplantation of mesenchymal stem cells cultured on biomatrix support induces repairing of digestive tract defects, in animal model.

    PubMed

    Sîrbu-Boeţi, Mirela-Patricia; Chivu, Mihaela; Pâslaru, Liliana Livia; Efrimescu, C; Herlea, V; Pecheanu, C; Moldovan, Lucia; Dragomir, Laura; Bleotu, Coralia; Ciucur, Elena; Vidulescu, Cristina; Vasilescu, Mihaela; Boicea, Anişoara; Mănoiu, S; Ionescu, M I; Popescu, I

    2009-01-01

    Transplanted mesenchymal stem cells (MSCs) appear to play a significant role in adult tissue repair. The aim of this research was to obtain MSCs enriched, three dimensional (3D) patches for transplant, and to test their ability to induce repair of iatrogenic digestive tract defects in rats. MSCs were obtained from human and rat bone marrow, cultured in vitro, and seeded in a collagen-agarose scaffold, where they showed enhanced viability and proliferation. The phenotype of the cultured cells was representative for MSCs (CD105+, CD90+, and CD34-, CD45-, CD3-, CD14-). The 3D patch was obtained by laying the MSCs enriched collagen-agarose scaffold on a human or swine aortic fragment. After excision of small portions of the rat digestive tract, the 3D patches were sutured at the edge of the defect using micro-surgical techniques. The rats were sacrificed at time-points and the regeneration of the digestive wall was investigated by immunofluorescence, light and electron microscopy. The MSCs enriched 3D patches were biocompatible, biodegradable, and prompted the regeneration of the four layers of the stomach and intestine wall in rats. Human cells were identified in the rat regenerated digestive wall as a hallmark of the transplanted MSCs. For the first time we constructed 3D patches made of cultured bone marrow MSCs, embedded into a collagen-rich biomatrix, on vascular bio-material support, and transplanted them in order to repair iatrogenic digestive tract defects. The result was a complete repair with preservation of the four layered structure of the digestive wall.

  16. INTERNAL REPAIR OF PIPELINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robin Gordon; Bill Bruce; Ian Harris

    2004-08-17

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, undermore » congested intersections, and under railway. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners, indicating that this type of liner is only marginally effective at restoring the pressure containing capabilities of pipelines. Failure pressures for larger diameter pipe repaired with a semi-circular patch of carbon fiber-reinforced composite lines were also marginally greater than that of a pipe section with un-repaired simulated damage without a liner. These results indicate that fiber reinforced composite liners have the potential to increase the burst pressure of pipe sections with external damage Carbon fiber based liners are viewed as more promising than glass fiber based liners because of the potential for more closely matching the mechanical properties of steel. Pipe repaired with weld deposition failed at pressures lower than that of un-repaired pipe in both the virgin and damaged conditions, indicating that this repair technology is less effective at restoring the pressure containing capability of pipe than a carbon fiber-reinforced liner repair. Physical testing indicates that carbon fiber-reinforced liner repair is the most promising technology evaluated to-date. Development of a comprehensive test plan for this process is recommended for use in the field trial portion of this program.« less

  17. Finite Element and Analytical Analysis of Cracks in Thick Stiffened Plates Repaired with a Single Sided Composite Patch

    DTIC Science & Technology

    2014-06-01

    DC,Tech. Rep. CG-D-05–00, 2000. [16] S. Kou, Welding Metallurgy , 2nd edition, Hoboken: Wiley Interscience, 2003. [17] C. Poe, “Stress intensity...continuous aluminum superstructure welded to the deck. The shape of the superstructure created numerous stress concentration areas. Of the greatest concern...study as it will help provide a conservative estimate. In marine applications almost all stiffening members are attached by welding . Unlike a

  18. Endovascular treatment of false-aneurysm ten years after dacron patch aortoplasty for coarctation of the aortic isthmus. Report of a case.

    PubMed

    Illuminati, Giulio; Pacilè, Maria Antonietta; Palumbo, Piergaspare; Salvatori, Filippo Maria; Vietri, Francesco

    2013-01-01

    False aneurysm degeneration is a known complication of patch aortoplasty for coarctation of the aortic isthmus. Open surgical treatment consists of prosthetic graft repair of the involved aorta, often requires circulatory arrest to achieve a safe proximal aortic control and perform proximal anastomosis, and finally is associated with substantial perioperative morbidity. Endografting of the diseased aorta is a valuable alternative to open repair, when feasible, with good short and long term results. We now report one more case of false aneurysm ten years after Dacron patch aortoplasty for isthmic coarctation in a 26-year-old woman, successfully treated by endovascular repair via the left common iliac artery, and a complete exclusion of the aneurysm at two year follow-up.

  19. Computer-aided patch planning for treatment of complex coarctation of the aorta

    NASA Astrophysics Data System (ADS)

    Rietdorf, Urte; Riesenkampff, Eugénie; Kuehne, Titus; Huebler, Michael; Meinzer, Hans-Peter; Wolf, Ivo

    2009-02-01

    Between five and eight percent of all children born with congenitally malformed hearts suffer from coarctations of the aorta. Some severe coarctations can only be treated by surgical repair. Untreated, this defect can cause serious damage to organ development or even lead to death. Patch repair requires open surgery. It can affect patients of any age: newborns with severe coarctation and/or hypoplastic aortic arch as well as older patients with late diagnosis of coarctation of the aorta. Another patient group are patients of varying age with re-coarctation of the aorta or hypoplastic aortic arch after surgical and/or interventional repair. If anatomy is complex and interventional treatment by catheterization, balloon angioplasty or stent placement is not possible, surgery is indicated. The choice of type of surgery depends not only on the given anatomy but also on the experience the surgical team has with each method. One surgical approach is patch repair. A patch of a suitable shape and size is sewed into the aorta to expand the aortic lumen at the site of coarctation. At present, the shape and size of the patch are estimated intra-operatively by the surgeon. We have developed a software application that allows planning of the patch pre-operatively on the basis of magnetic resonance angiographic data. The application determines the diameter of the coarctation and/or hypoplastic segment and constructs a patch proposal by calculating the difference to the normal vessel diameter pre-operatively. Evaluation of MR angiographic datasets from 12 test patients with different kinds of aortic arch stenosis shows a divergence of only (1.5+/-1.2) mm in coarctation diameters between manual segmentations and our approach, with comparable time expenditure. Following this proposal the patch can be prepared and adapted to the patient's anatomy pre-operatively. Ideally, this leads to shorter operation times and a better long-term outcome with a reduced rate of residual stenosis and re-stenosis and aneurysm formation.

  20. Surgical repair of supravalvular aortic stenosis in children with williams syndrome: a 30-year experience.

    PubMed

    Fricke, Tyson A; d'Udekem, Yves; Brizard, Christian P; Wheaton, Gavin; Weintraub, Robert G; Konstantinov, Igor E

    2015-04-01

    Williams syndrome is an uncommon genetic disorder associated with supravalvular aortic stenosis (SVAS) in childhood. We reviewed outcomes of children with Williams syndrome who underwent repair of SVAS during a 30-year period at a single institution. Between 1982 and 2012, 28 patients with Williams syndrome were operated on for SVAS. Mean age at operation was 5.2 years (range, 3 months to 13 years), and mean weight at operation was 18.6 kg (range, 4.1 to 72.4 kg). Associated cardiac lesions in 11 patients (39.3%) were repaired at the time of the SVAS repair. The most common associated cardiac lesion was main pulmonary artery stenosis (8 of 28 [28%]). A 3-patch repair was performed in 10 patients, a Doty repair in 17, and a McGoon repair in 1 (3.6%). There were no early deaths. Follow-up was 96% complete (27 of 28). Overall mean follow-up was 11.2 years (range, 1 month to 27.3 years). Mean follow-up was 5 years (range, 1 month to 14.3 years) for the 3-patch repair patients and 14.7 years (range, 6 weeks to 27 years) for the Doty repair patients. Of the 17 Doty patients, there were 4 (24%) late deaths, occurring at 6 weeks, 3.5 years, 4 years, and 16 years after the initial operation. There were no late deaths in the 3-patch repair patients. Overall survival was 86% at 5, 10, and 15 years after repair. Survival was 82% at 5, 10 and 15 years for the Doty repair patients. Overall, 6 of 27 patients (22%) patients required late reoperation at a mean of 11.2 years (range, 3.6 to 23 years). No 3-patch repair patients required reoperation. Overall freedom from reoperation was 91% at 5 years and 73% at 10 and 15 years. Freedom from reoperation for the Doty repair patients was 93% at 5 years and 71% at 10 and 15 years. Surgical repair of SVAS in children Williams syndrome has excellent early results. However, significant late mortality and morbidity warrants close follow-up. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. The benefit of synthetic versus biological patch augmentation in the repair of posterosuperior massive rotator cuff tears: a 3-year follow-up study.

    PubMed

    Ciampi, Pietro; Scotti, Celeste; Nonis, Alessandro; Vitali, Matteo; Di Serio, Clelia; Peretti, Giuseppe M; Fraschini, Gianfranco

    2014-05-01

    Rotator cuff repair typically results in a satisfactory, although variable, clinical outcome. However, anatomic failure of the repaired tendon often occurs. Patch augmentation can improve the results of open rotator cuff repair by supporting the healing process, protecting the suture, and reducing friction in the subacromial space. Cohort study; Level of evidence, 3. A total of 152 patients with a posterosuperior massive rotator cuff tear were treated by open repair only (control group; n = 51; mean age, 67.06 ± 4.42 years), open repair together with collagen patch augmentation (collagen group; n = 49; mean age, 66.53 ± 5.17 years), or open repair together with polypropylene patch augmentation (polypropylene group; n = 52; mean age, 66.17 ± 5.44 years) and were retrospectively studied. Patients were evaluated preoperatively and after 36 months with a visual analog scale (VAS) and the University of California, Los Angeles (UCLA) shoulder rating scale and by measuring elevation of the scapular plane and strength with a dynamometer. The VAS and UCLA scores were also obtained 2 months postoperatively. Tendon integrity was assessed after 1 year by ultrasound. Patients were homogeneous as per the preoperative assessment. After 2 months, results (mean ± standard deviation) for the control, collagen, and polypropylene groups, respectively, were as follows: VAS scores were 6.96 ± 1.11, 6.46 ± 1.02, and 4.92 ± 0.90, while UCLA scores were 11.29 ± 1.46, 11.40 ± 1.51, and 19.15 ± 1.99. After 36 months, the mean scores for the respective groups were 3.66 ± 1.05, 4.06 ± 1.02, and 3.28 ± 1.10 for the VAS and 14.88 ± 1.98, 14.69 ± 1.99, and 24.61 ± 3.22 for the UCLA scale. In addition, after 36 months, elevation on the scapular plane was 140.68° ± 9.84°, 140.61° ± 12.48°, and 174.71° ± 8.18°, and abduction strength was 8.73 ± 0.54 kg, 9.03 ± 0.60 kg, and 13.79 ± 0.64 kg for the control, collagen, and polypropylene groups, respectively. The retear rate after 12 months was 41% (21/51) for the control group, 51% (25/49) for the collagen group, and 17% (9/52) for the polypropylene group. In particular, the reduced 12-month retear rate and the increased UCLA scores, abduction strength, and elevation at 3-year follow-up were statistically significant for patients treated with a polypropylene patch compared with those treated with repair only or with a collagen patch. Polypropylene patch augmentation of rotator cuff repair was demonstrated to significantly improve the 36-month outcome in terms of function, strength, and retear rate.

  2. Generalized Peritonitis Requiring Re-operation After Leakage of Omental Patch Repair of Perforated Peptic Ulcer

    PubMed Central

    Maghsoudi, Hemmat; Ghaffari, Alireza

    2011-01-01

    Background/Aim: Peptic ulcer perforations are a common emergency, but available literature is silent on the exact definition, incidence, management, and complications of peritonitis due to omental patch leakage. Patients and Methods: Retrospective data were collected on 422 patients who underwent omental patch repair of perforated peptic ulcer between March 20, 1999 and March 20, 2006. The definitive diagnosis of perforated peptic ulcer and omental patch leakage was obtained at surgery. Results: Seventeen (4%) patients experienced generalized peritonitis due to omental patch leakage. Mean age was 60.6 years. Mortality rate was 29.4%, and the mean hospital stay was 23.6 days. Delay in surgical approach, shock on admission, and age were all significantly associated with increased mortality. Conclusions: Peritonitis due to omental patch leakage can result in significant morbidity and mortality. The most common causes of omental patch leakage and operative procedures were unknown and reinsertion of omentum, respectively. Factors such as shock on admission or delayed surgery, have significantly contributed to fatal outcomes and need careful attention. PMID:21372350

  3. Construction and characterization of mismatch-containing circular DNA molecules competent for assessment of nick-directed human mismatch repair in vitro.

    PubMed

    Larson, Erik D; Nickens, David; Drummond, James T

    2002-02-01

    The ability of cell-free extracts to correct DNA mismatches has been demonstrated in both prokaryotes and eukaryotes. Such an assay requires a template containing both a mismatch and a strand discrimination signal, and the multi-step construction process can be technically difficult. We have developed a three-step procedure for preparing DNA heteroduplexes containing a site-specific nick. The mismatch composition, sequence context, distance to the strand signal, and the means for assessing repair in each strand are adjustable features built into a synthetic oligonucleotide. Controlled ligation events involving three of the four DNA strands incorporate the oligonucleotide into a circular template and generate the repair-directing nick. Mismatch correction in either strand of a prototype G.T mismatch was achieved by placing a nick 10-40 bp away from the targeted base. This proximity of nick and mismatch represents a setting where repair has not been well characterized, but the presence of a nick was shown to be essential, as was the MSH2/MSH6 heterodimer, although low levels of repair occurred in extract defective in each protein. All repair events were inhibited by a peptide that interacts with proliferating cell nuclear antigen and inhibits both mismatch repair and long-patch replication.

  4. Evaluation of precast patches on U.S. 60 near the New Kent and James City County line.

    DOT National Transportation Integrated Search

    2006-01-01

    This project evaluated the use of precast concrete patches for repairing jointed concrete pavement. Six patches were placed: three had dowels cast into them during fabrication, and three had dowels inserted in place (dowel bar retrofit). Fabrication ...

  5. Treatment of massive and recurrent rotator cuff tears augmented with a poly-l-lactide graft, a preliminary study.

    PubMed

    Lenart, Brett A; Martens, Kelly A; Kearns, Kenneth A; Gillespie, Robert J; Zoga, Adam C; Williams, Gerald R

    2015-06-01

    The incidence of failed rotator cuff repairs remains high, especially in the setting of massive tears or revision repairs. The purpose of this study was to evaluate patient outcomes and repair integrity after augmentation with the repair patch, a poly-l-lactide synthetic polymer. Sixteen consecutive patients with massive or recurrent rotator cuff tears underwent open repair with synthetic poly-l-lactide patch augmentation. Two patients required the patch to bridge defects, and 1 patient retore after a motor vehicle accident and had revision surgery at another institution. The 13 remaining patients were retrospectively evaluated from 1.2 to 1.7 years (average, 1.5 years) after surgery by PENN, American Shoulder and Elbow Surgeons, and Single Assessment Numeric Evaluation scores. Magnetic resonance imaging was used to examine the integrity of the repair at a minimum of 1 year of follow-up. The mean age was 57.3 years (42-68 years). Five patients (38%) had an intact rotator cuff at the time of follow-up. The remaining patients (62%) had full-thickness tears. PENN scores significantly improved from a preoperative score of 50.9 to 77.6 (P < .005). American Shoulder and Elbow Surgeons scores significantly improved from 32.8 to 74.2 (P = .0001). Single Assessment Numeric Evaluation scores at latest follow-up were 76.2. Poly-l-lactide repair patch augmentation of massive and recurrent large to massive rotator cuff tears demonstrates significant improvement in shoulder outcome measures for this difficult population, despite a retear rate of 62%. Further investigation with larger, prospective long-term studies is needed to determine whether this technique provides a true benefit compared with traditional, nonaugmented repair. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  6. Influence of very short patch mismatch repair on SOS inducing lesions after aminoglycoside treatment in Escherichia coli.

    PubMed

    Baharoglu, Zeynep; Mazel, Didier

    2014-01-01

    Low concentrations of aminoglycosides induce the SOS response in Vibrio cholerae but not in Escherichia coli. In order to determine whether a specific factor present in E. coli prevents this induction, we developed a genetic screen where only SOS inducing mutants are viable. We identified the vsr gene coding for the Vsr protein of the very short patch mismatch repair (VSPR) pathway. The effect of mismatch repair (MMR) mutants was also studied. We propose that lesions formed upon aminoglycoside treatment are preferentially repaired by VSPR without SOS induction in E. coli and by MMR when VSPR is impaired. Copyright © 2014 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  7. Nondestructive and Strain Testing of Composite Sandwich Panels

    NASA Astrophysics Data System (ADS)

    Goyings, Ryan

    In April 2006, Sikorsky Aircraft received a contract from the United States Marine Corps (USMC) to develop a successor to their CH-53E heavy-lift helicopter. The new designation is the CH-53K "Super Stallion" and provides increased operating capabilities through the use of design revisions that incorporate extensive use of carbon fiber composites and composite sandwich panels. "The CH-53K will have five times the capability at half of the operational cost of the aircraft it's replacing. It will be the most capable helicopter ever produced. With more than twice the combat radius of the CH-53E, the CH-53K uses mature technology to deliver a fully shipboard compatible platform to meet current and future Marine Corps requirements". Upon introduction, it will be the largest rotary wing aircraft in the United States Department of Defense. The USMC will incorporate the CH-53K into the Joint Operations Concept of Full Spectrum Dominance and Sea Power 21 thereby enabling rapid, decisive operations and the early termination of conflict by projecting and sustaining forces to distant anti-access, area-denial environments. Even with an increased lift capability, the CH-53K is a slow moving, low flying helicopter susceptible to damage from small arms fire. There is no field level composite repair capability within any maintained documents published by the Department of Defense. Purdue University has developed a field level rapid repair technique capable of returning strength and integrity to damaged carbon composite structural components. The patch is made from carbon fiber weave that is applied using a field capable Vacuum Assisted Resin Transfer Molding (VARTM). This thesis seeks to validate, using nondestructive testing methods and strain monitoring, the manufacturing, damage, and repair process of composite sandwich panels representative of the CH-53K structural panels.

  8. Evaluation of bonding agent application on concrete patch performance.

    DOT National Transportation Integrated Search

    2014-08-01

    The durability of partial depth repair is directly related to the bond strength between the repair material and existing : concrete. Bond strength development sensitivity to wait time with the use of bonding agents in partial depth repair was : inves...

  9. Effect of platelet-rich plasma and porcine dermal collagen graft augmentation for rotator cuff healing in a rabbit model.

    PubMed

    Chung, Seok Won; Song, Byung Wook; Kim, Yeun Ho; Park, Kyoung Un; Oh, Joo Han

    2013-12-01

    The rate of healing failure after surgical repair of chronic rotator cuff tears is considerably high. To verify the effect of platelet-rich plasma (PRP) with and without porcine dermal collagen graft augmentation on tendon-to-bone healing, using the rabbit supraspinatus tendon. Controlled laboratory study. A total of 80 rabbits were randomly allocated into 4 groups (20 rabbits per group: 12 for histological and 8 for mechanical testing): repair (R), repair + patch augmentation (RPa), repair + PRP (RPr), and repair + patch + PRP (RPaPr). The right shoulder was used for experimental interventions, and the left served as a control. Six weeks after the detachment of the supraspinatus, the torn tendon was repaired in a transosseous manner, simulating double-row repair in all groups. Platelet-rich plasma was prepared and applied onto the repair site in the RPr and RPaPr groups, and the patch was used to augment the repair in the RPa and RPaPr groups. The mechanical tensile strength test was performed at 8 weeks after repair and the histological evaluation at 4 and 8 weeks. At 4 weeks, the collagen fibers were poorly organized, and fiber continuity was not established in all groups. However, vascularity and cellularity were higher with granulation tissue formation in the PRP-treated groups (RPr and RPaPr) than the nontreated groups (R and RPa). At 8 weeks, tendon-to-bone integration was much improved with more collagen fibers, and longitudinally oriented collagen fibers were visible in all groups. The PRP-treated groups showed better collagen fiber continuity and orientation than the nontreated groups; however, no distinctive difference was found between the patch-augmented groups (RPa and RPaPr) and nonaugmented groups (R and RPr). The mean load-to-failure results were 61.57 ± 29.99 N, 76.84 ± 16.08 N, 105.35 ± 33.82 N, and 117.93 ± 12.60 N for the R, RPa, RPr, and RPaPr groups, respectively, and they were significantly different between the R and RPr (P = .018), R and RPaPr (P = .002), and RPa and RPaPr (P = .029) groups. This animal study showed the enhancement of tendon-to-bone healing after local administration of autologous PRP assessed by histological and biomechanical testing in a rabbit model of chronic rotator cuff tears. However, there was little additive effect of the patch graft. The use of PRP might be a biological supplement to increase the rotator cuff healing rate, which still remains low even after successful cuff repair, but this result should be interpreted with caution regarding clinical applications.

  10. Partial-depth precast concrete patching.

    DOT National Transportation Integrated Search

    1974-01-01

    Experiments were performed with partial-depth precast concrete patching to determine the feasibility of the method. In the experiments prefabricated slabs of various sizes, stockpiled near the pavement repair site were installed in machine cut holes ...

  11. Cementitious materials for thin patches : final report.

    DOT National Transportation Integrated Search

    2001-06-01

    Ten cementitious patching materials, which were suitable for thin, vertical repairs according to the manufacturers, were evaluated. Compatibility with cathodic protection systems was a particular concern. The materials were tested for propensity to c...

  12. DNA repair in mammalian mitochondria: Much more than we thought?

    PubMed

    Liu, Pingfang; Demple, Bruce

    2010-06-01

    For many years, the repair of most damage in mitochondrial DNA (mtDNA) was thought limited to short-patch base excision repair (SP-BER), which replaces a single nucleotide by the sequential action of DNA glycosylases, an apurinic/apyrimidinic (AP) endonuclease, the mitochondrial DNA polymerase gamma, an abasic lyase activity, and mitochondrial DNA ligase. However, the likely array of lesions inflicted on mtDNA by oxygen radicals and the possibility of replication errors and disruptions indicated that such a restricted repair repertoire would be inadequate. Recent studies have considerably expanded our knowledge of mtDNA repair to include long-patch base excision repair (LP-BER), mismatch repair, and homologous recombination and nonhomologous end-joining. In addition, elimination of mutagenic 8-oxodeoxyguanosine triphosphate (8-oxodGTP) helps prevent cell death due to the accumulation of this oxidation product in mtDNA. Although it was suspected for many years that irreparably damaged mtDNA might be targeted for degradation, only recently was clear evidence provided for this hypothesis. Therefore, multiple DNA repair pathways and controlled degradation of mtDNA function together to maintain the integrity of mitochondrial genome.

  13. Off-pump repair of a post-infarct ventricular septal defect: the 'Hamburger procedure'

    PubMed Central

    Barker, Thomas A; Ng, Alexander; Morgan, Ian S

    2006-01-01

    We report a novel off-pump technique for the surgical closure of post-infarct ventricular septal defects (VSDs). The case report describes the peri-operative management of a 76 year old lady who underwent the 'Hamburger procedure' for closure of her apical VSD. Refractory cardiogenic shock meant that traditional patch repairs requiring cardiopulmonary bypass would be poorly tolerated. We show that echocardiography guided off-pump posterior-anterior septal plication is a safe, effective method for closing post-infarct VSDs in unstable patients. More experience is required to ascertain whether this technique will become an accepted alternative to patch repairs. PMID:16722552

  14. Remote reactor repair: GTA (gas tungsten Arc) weld cracking caused by entrapped helium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanne, Jr, W R

    1988-01-01

    A repair patch was welded to the wall of a nuclear reactor tank using remotely controlled thirty-foot long robot arms. Further repair was halted when gas tungsten arc (GTA) welds joining type 304L stainless steel patches to the 304 stainless steel wall developed toe cracks in the heat-affected zone (HAZ). The role of helium in cracking was investigated using material with entrapped helium from tritium decay. As a result of this investigation, and of an extensive array of diagnostic tests performed on reactor tank wall material, helium embrittlement was shown to be the cause of the toe cracks.

  15. Living cardiac patch: the elixir for cardiac regeneration.

    PubMed

    Lakshmanan, Rajesh; Krishnan, Uma Maheswari; Sethuraman, Swaminathan

    2012-12-01

    A thorough understanding of the cellular and muscle fiber orientation in left ventricular cardiac tissue is of paramount importance for the generation of artificial cardiac patches to treat the ischemic myocardium. The major challenge faced during cardiac patch engineering is to choose a perfect combination of three entities; cells, scaffolds and signaling molecules comprising the tissue engineering triad for repair and regeneration. This review provides an overview of various scaffold materials, their mechanical properties and fabrication methods utilized in cardiac patch engineering. Stem cell therapies in clinical trials and the commercially available cardiac patch materials were summarized in an attempt to provide a recent perspective in the treatment of heart failure. Various tissue engineering strategies employed thus far to construct viable thick cardiac patches is schematically illustrated. Though many strategies have been proposed for fabrication of various cardiac scaffold materials, the stage and severity of the disease condition demands the incorporation of additional cues in a suitable scaffold material. The scaffold may be nanofibrous patch, hydrogel or custom designed films. Integration of stem cells and biomolecular cues along with the scaffold may provide the right microenvironment for the repair of unhealthy left ventricular tissue as well as promote its regeneration.

  16. New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case.

    PubMed

    Berezina, Tamara L; Fechtner, Robert D; Cohen, Amir; Kim, Eliott E; Chu, David S

    2015-01-01

    We present the case of successful repair of an exposed glaucoma drainage tube by cornea graft fixation with tissue adhesive, and without subsequent coverage by adjacent conjunctiva or donor tissues. Patient with history of keratoglobus with thin cornea and sclera, and phthisical contralateral eye, underwent three unsuccessful corneal grafts followed by Boston type 1 keratoprosthesis in the right eye. Ahmed drainage device with sclera patch graft was implanted to control the intraocular pressure. Two years later the tube eroded through sclera graft and conjunctiva. Repair was performed by covering the tube with a corneal patch graft secured by tissue adhesive after the conjunctiva in this area was dissected away. The cornea graft was left uncovered due to fragility of adjacent conjunctiva. The healing of ocular and graft surfaces was complete prior to the 1 month follow-up. Conjunctival epithelium covered the corneal patch graft. At 12 months follow-up, the graft and the tube remained stable. Our report suggests that corneal patch graft fixation to the sclera by means of tissue adhesive, without closing the conjunctiva, can be considered as an effective alternative surgical approach for managing exposed glaucoma drainage tube, accompanied by adjacent conjunctiva tissue deficiency. How to cite this article: Berezina TL, Fechtner RD, Cohen A, Kim EE, Chu DS. New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case. J Curr Glaucoma Pract 2015;9(2):62-64.

  17. Evaluation of concrete patching materials : final report.

    DOT National Transportation Integrated Search

    1985-01-01

    The project evaluated numerous repairs on portland cement concrete pavements and bridge decks made with a number of laboratory accepted, proprietary patching materials and portland cement concrete mixtures of different designs. It was ascertained tha...

  18. Deep patch technique for landslide repair. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helwany, B.M.

    1994-10-01

    The report describes the laboratory testing of the `USFS deep patch` technique and a CTI modification of this technique for repairing landslides with geosynthetic reinforcement. The technique involves replacing sections of roadway lost due to landslides on top of a geosynthetically-reinforced embankment. The CTI modification involves replacing the reinforced slope with a geosynthetically-reinforced retaining wall with a truncated base. Both techniques rely on the cantilevering ability of the reinforced mass to limit the load on the foundation with a high slide potential. The tests with road base showed that (1) both the USFS and CTI repair reduced effectively the adversemore » effects of local landsliding on the highway pavement by preventing crack propagation; (2) the USFS repair increased the stability of the repaired slope, which was in progressive failure, by reducing the stresses exerted on it; and (3) the CTI repair produced substantially greater stresses on its foundation due to the truncated base of the reinforced mass.« less

  19. Omental patch repair effectively treats perforated marginal ulcer following Roux-en-Y gastric bypass.

    PubMed

    Wendling, Mark R; Linn, John G; Keplinger, Kara M; Mikami, Dean J; Perry, Kyle A; Melvin, W Scott; Needleman, Bradley J

    2013-02-01

    Marginal ulcer formation remains a significant complication of Roux-en-Y gastric bypass (RYGB). Up to 1 % of all RYGB patients will develop free perforation of a marginal ulcer. Classically, this complication has required anastomotic revision; however, this approach is associated with significant morbidity. Several small series have suggested that omental patch repair may be effective. The aim of this study was to examine the management of perforated marginal ulcers following RYGB. All patients who underwent operative intervention for perforated ulcers between 2003 and 2011 were reviewed. Those with a history of RYGB with perforation of a marginal ulcer were included in the analysis. Data collected included operative approach, operative time, blood loss, length of hospital stay, complications, smoking history, and steroid or NSAID use. From January 2003 to December 2011, a total of 1,760 patients underwent RYGB at our institution. Eighteen (0.85 %) developed perforation of a marginal ulcer. Three patients' original procedure was performed at another institution. Eight patients (44 %) had at least one risk factor for ulcer formation. Treatment included omental patch repair (laparoscopic, n = 7; open, n = 9) or anastomotic revision (n = 2). Compared to anastomotic revision, omental patch repair had shorter OR time (101 ± 57 vs. 138 ± 2 min), decreased estimated blood loss (70 ± 72 vs. 250 ± 71 mL), and shorter total length of stay (5.6 ± 1.4 vs. 11.0 ± 5.7 days). Perforated marginal ulcer represents a significant complication of RYGB. Patients should be educated to reduce risk factors for perforation, as prolonged proton pump inhibitor therapy may not prevent this complication in a patient with even just one risk factor. In our sample population we found laparoscopic or open omental patch repair to be a safe and effective treatment for this condition and it was associated with decreased operative time, blood loss, and length of stay.

  20. Pothole repair

    DOT National Transportation Integrated Search

    1999-11-01

    The primary objective of the pothole experiment was to determine which combinations of materials and patching procedures provide the most cost-effective repair of potholes in asphalt concrete-surfaced pavements. This technical summary summarizes the ...

  1. The fabrication and characterization of a multi-laminate, angle-ply collagen patch for annulus fibrosus repair.

    PubMed

    McGuire, Rachel; Borem, Ryan; Mercuri, Jeremy

    2017-12-01

    One major limitation of intervertebral disc (IVD) repair is that no ideal biomaterial has been developed that effectively mimics the angle-ply collagen architecture and mechanical properties of the native annulus fibrosus (AF). Furthermore, it would be beneficial to devise a simple, scalable process by which to manufacture a biomimetic biomaterial that could function as a mechanical repair patch to be secured over a large defect in the outer AF that will support AF tissue regeneration. Such a biomaterial would: (1) enable the employment of early-stage interventional strategies to treat IVD degeneration (i.e. nucleus pulposus arthroplasty); (2) prevent IVD re-herniation in patients with large AF defects; and (3) serve as a platform to develop full-thickness AF and whole IVD tissue engineering strategies. Due to the innate collagen fibre alignment and mechanical strength of pericardium, a procedure was developed to assemble multi-laminate angle-ply AF patches derived from decellularized pericardial tissue. Patches were subsequently assessed histologically to confirm angle-ply microarchitecture, and mechanically assessed for biaxial burst strength and tensile properties. Additionally, patch cytocompatibility was evaluated following seeding with bovine AF cells. This study demonstrated the effective removal of porcine cell remnants from the pericardium, and the ability to reliably produce multi-laminate patches with angle-ply architecture using a simple assembly technique. Resultant patches demonstrated their inherent ability to resist biaxial burst pressures reminiscent of intradiscal pressures commonly borne by the AF, and exhibited tensile strength and modulus values reported for native human AF. Furthermore, the biomaterial supported AF cell viability, infiltration and proliferation. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Handbook for Repairing Nonconventional Roofing Systems

    DTIC Science & Technology

    1988-12-01

    membrane. 61 PIMB (solvent) Figure 71. Apply welding solvent to the PIB patch. Figure 72. Work the solvent Into the P113 patch. Pila 62 (solvent) Figure 73...when exposed to flame but will not burn nor support combustion . PVC repair techniques are basically the same as for a new application of a PVC fully...granules (if desired) before the final coat dries. 83 PUF F4gue 102. Remove the damaged material and bevel the s! des of the hole. 4󈧵, Figure 103. Trim th

  3. Analysis of aggregate pier systems for stabilization of subgrade settlement.

    DOT National Transportation Integrated Search

    2014-12-01

    Every year, ODOT undertakes numerous pavement patching/resurfacing projects to repair pavement : distress and structural failure due to soft and/or organic soils constituting the subgrade. Other than the : temporary solution of patching/resurfacing, ...

  4. Evaluation of cold mixes for winter pothole repair.

    DOT National Transportation Integrated Search

    1995-01-01

    This study was conducted to evaluate the performance of 13 proprietary cold-mix patching materials, 4 of which are currently approved under a Virginia Department of Transportation (VDOT) Special Provision for High Quality Cold Patching Materials. Col...

  5. Research notes : alternate method for pothole patching.

    DOT National Transportation Integrated Search

    1998-09-01

    Typically, throw and roll pothole patches will likely fail before the pavement is resurfaced or rehabilitated. Alternatively, semi-permanent repairs are time consuming and require more people and added lane closure time. An alternate method is spray ...

  6. Bacterial genes mutL, mutS, and dcm participate in repair of mismatches at 5-methylcytosine sites.

    PubMed Central

    Lieb, M

    1987-01-01

    Certain amber mutations in the cI gene of bacteriophage lambda appear to recombine very frequently with nearby mutations. The aberrant mutations included C-to-T transitions at the second cytosine in 5'CC(A/T)GG sequences (which are subject to methylation by bacterial cytosine methylase) and in 5'CCAG and 5'CAGG sequences. Excess cI+ recombinants arising in crosses that utilize these mutations are attributable to the correction of mismatches by a bacterial very-short-patch (VSP) mismatch repair system. In the present study I found that two genes required for methyladenine-directed (long-patch) mismatch repair, mutL and mutS, also functioned in VSP mismatch repair; mutH and mutU (uvrD) were dispensable. VSP mismatch repair was greatly reduced in a dcm Escherichia coli mutant, in which 5-methylcytosine was not methylated. However, mismatches in heteroduplexes prepared from lambda DNA lacking 5-methylcytosine were repaired in dcm+ bacteria. These results indicate that the product of gene dcm has a repair function in addition to its methylase activity. PMID:2959653

  7. The "Flat Diaphragm": Does the Degree of Curvature of the Diaphragm on Postoperative X-Ray Predict Congenital Diaphragmatic Hernia Recurrence?

    PubMed

    Short, Heather L; Clifton, Matthew S; Arps, Kelly; Travers, Curtis; Loewen, Jonathan; Schlager, Avraham

    2018-04-01

    The appearance of the diaphragmatic curvature and the rib insertion level of the diaphragm on postoperative chest X-ray (CXR) may predict recurrence. Our purpose was to examine the relationship between the curvature of the diaphragm on postoperative CXR and recurrence. We performed a retrospective review of left-sided, Bochdalek congenital diaphragmatic hernia (CDH) surgical repairs from 2004 to 2015 at a single institution. We developed a tool to measure the flatness of the diaphragm on postoperative CXR, termed the diaphragmatic curvature index (τ). The primary outcome of interest was recurrence after surgical repair. Of the 127 patients identified, 54% (n = 69) had a primary repair, while 46% (n = 58) required a patch repair. The overall recurrence rate was 21.3% (n = 27). There was no difference in median lateral rib insertion level in patients with and without recurrence or those who had a primary or patch repair. The overall median diaphragmatic curvature index was 6.29 (interquartile range [IQR] 5.30-8.09) and was not significantly different among patients who had a recurrence (6.00, IQR 5.34-8.24) and those who did not (6.46, IQR 5.24-8.07) (P = .853). Within the primary repair group (6.34 versus 6.93, P = .84) and the patch repair group (5.59 versus 6.18, P = .46), the median diaphragmatic curvature index was not different among patients who had a recurrence and those who did not. A flat appearance of the diaphragm on postoperative CXR as measured by the median diaphragmatic curvature index (τ) is not associated with recurrence. The shape of the diaphragm on CXR after CDH repair may not be predictive of recurrence as previously thought.

  8. Damage Tolerant Analysis of Cracked Al 2024-T3 Panels repaired with Single Boron/Epoxy Patch

    NASA Astrophysics Data System (ADS)

    Mahajan, Akshay D.; Murthy, A. Ramachandra; Nanda Kumar, M. R.; Gopinath, Smitha

    2018-06-01

    It is known that damage tolerant analysis has two objectives, namely, remaining life prediction and residual strength evaluation. To achieve the these objectives, determination of accurate and reliable fracture parameter is very important. XFEM methodologies for fatigue and fracture analysis of cracked aluminium panels repaired with different patch shapes made of single boron/epoxy have been developed. Heaviside and asymptotic crack tip enrichment functions are employed to model the crack. XFEM formulations such as displacement field formulation and element stiffness matrix formulation are presented. Domain form of interaction integral is employed to determine Stress Intensity Factor of repaired cracked panels. Computed SIFs are incorporated in Paris crack growth model to predict the remaining fatigue life. The residual strength has been computed by using the remaining life approach, which accounts for both crack growth constants and no. of cycles to failure. From the various studies conducted, it is observed that repaired panels have significant effect on reduction of the SIF at the crack tip and hence residual strength as well as remaining life of the patched cracked panels are improved significantly. The predicted remaining life and residual strength will be useful for design of structures/components under fatigue loading.

  9. Novel engineered tendon-fibrocartilage-bone composite with cyclic tension for rotator cuff repair.

    PubMed

    Liu, Qian; Hatta, Taku; Qi, Jun; Liu, Haoyu; Thoreson, Andrew R; Amadio, Peter C; Moran, Steven L; Steinmann, Scott P; Gingery, Anne; Zhao, Chunfeng

    2018-05-15

    Surgical repair of rotator cuff tears presents a significant clinical challenge with high failure rates and inferior functional outcomes. Graft augmentation improves repair outcomes, however currently available grafting materials have limitations. While cell-seeded decellularized tendon slices may facilitate cell infiltration, promote tendon incorporation and preserve original mechanical strength, the unique fibrocartilage zone is yet to be successfully reestablished. In this study, we investigated the biological and mechanical properties of an engineered tendon-fibrocartilage-bone composite (TFBC) with cyclic tension (3% strain, 0.2 Hz). Decellularized TFBCs seeded with bone marrow-derived mesenchymal stem cell (BMSCs) sheets and subjected to mechanical stimulation for up to 7 days, were characterized by histology, immunohistochemistry, scanning electron microscopy, mechanical testing, and transcriptional regulation. The decellularized TFBC maintained native enthesis structure and properties. Mechanically stimulated TFBC-BMSC constructs displayed increased cell migration after 7 days of culture compared to static groups. The seeded cell sheet not only integrated well with tendon scaffold but also distributed homogeneously and aligned to the direction of stretch under dynamic culture. Developmental genes were regulated including, scleraxis which was significantly upregulated with mechanical stimulation. The Young's modulus of the cell-seeded constructs was significantly higher compared to the non-cell-seeded controls. In conclusion, the results of this study reveal that the TFBC-BMSC composite provides an ideal multilayer construct for cell seeding and growth, with mechanical preconditioning further enhances cell penetration and differentiation. The BMSC cell sheet revitalized TFBC in conjunction with mechanical stimulation could serve as a novel and primed biological patch to improve rotator cuff repair. This article is protected by copyright. All rights reserved.

  10. Partial-depth repair of jointed PCC pavements : cast-in-place and precast procedures.

    DOT National Transportation Integrated Search

    1977-01-01

    The installation of durable patches on jointed portland cement concrete pavement using several types of cast-in-place concrete, is described. The recommended procedures for pavement preparation and patch installation are given, and additional mainten...

  11. In vivo results of hydrogel composite pericardial substitutes.

    PubMed

    Blue, M A; Guilbeau, E J; Brandon, T A; Walker, A S; Bjotvedt, G; Fisk, R L

    1991-01-01

    In this study, two improved pericardial patches were developed and evaluated for their efficacy as pericardial substitutes. The patches are composites consisting of a hydrogel (PHEMA) that coats an underlying mesh (either ETFE or PET). Studies were conducted using subcutaneous implants in rats and pericardial patch implants in greyhound dogs. Adhesions between the substitute and pericardium and the epicardium were minimal. The ETFE composite patch caused an unacceptable epicardial reaction. The PET patch results were encouraging; the epicardium was largely unaffected by the patch.

  12. Modeling and Application of Piezoelectric Materials in Repair of Engineering Structures

    NASA Astrophysics Data System (ADS)

    Wu, Nan

    The shear horizontal wave propagation and vibration of piezoelectric coupled structures under an open circuit electrical boundary condition are studied. Following the studies on the dynamic response of piezoelectric coupled structures, the repair of both crack/notch and delaminated structures using piezoelectric materials are conducted. The main contribution was the proposed the active structural repair design using piezoelectric materials for different structures. An accurate model for the piezoelectric effect on the shear wave propagation is first proposed to guide the application of piezoelectric materials as sensors and actuators in the repair of engineering structures. A vibration analysis of a circular steel substrate surface bonded by a piezoelectric layer with open circuit is presented. The mechanical models and solutions for the wave propagation and vibration analysis of piezoelectric coupled structures are established based on the Kirchhoff plate model and Maxwell equation. Following the studies of the dynamic response of piezoelectric coupled structures, a close-loop feedback control repair methodology is proposed for a vibrating delaminated beam structure by using piezoelectric patches. The electromechanical characteristic of the piezoelectric material is employed to induce a local shear force above the delamination area via an external actuation voltage, which is designed as a feedback of the deflection of a vibrating beam and a delaminated plate, to reduce the stress singularity around the delamination tips. Furthermore, an experimental realization of an effective repair of a notched cantilever beam structure subjected to a dynamic loading by use of piezoelectric patches is reported. A small piezoelectric patch used as a sensor is placed on the notch position to monitor the severity of the stress singularity around the notch area by measuring the charge output on the sensor, and a patch used as an actuator is located around the notch area to generate a required bending moment by employing an actuation voltage to reduce the stress singularity at the notch position. The actuation voltage on the actuator is designed from a feedback circuit process. Through the analytical model, FEM simulation and experimental studies, the active structural repair method using piezoelectric materials is realized and proved to be feasible and practical.

  13. Repair of Tricuspid Valve Leaflet With CardioCel Patch After Traumatic Tricuspid Regurgitation.

    PubMed

    Konstantinidou, Maria Kalliopi; Moat, Neil

    2017-09-01

    Posttraumatic tricuspid valve regurgitation (TR) is a rare entity and is almost always associated with blunt chest trauma. It is usually identified by transthoracic echocardiography after the manifestation of clinical symptoms of heart failure. Treatment varies from long-term medical therapy and observation to surgical correction with tricuspid valve replacement or repair. We describe the case of a 26-year-old man who was involved in a major road traffic accident and was referred for surgical repair a year later because of severe posttraumatic TR. The tricuspid valve was successfully reconstructed with a CardioCel patch, Gore-Tex neochordae, and a tricuspid ring. The patient recovered well. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Base Excision Repair

    PubMed Central

    Krokan, Hans E.; Bjørås, Magnar

    2013-01-01

    Base excision repair (BER) corrects DNA damage from oxidation, deamination and alkylation. Such base lesions cause little distortion to the DNA helix structure. BER is initiated by a DNA glycosylase that recognizes and removes the damaged base, leaving an abasic site that is further processed by short-patch repair or long-patch repair that largely uses different proteins to complete BER. At least 11 distinct mammalian DNA glycosylases are known, each recognizing a few related lesions, frequently with some overlap in specificities. Impressively, the damaged bases are rapidly identified in a vast excess of normal bases, without a supply of energy. BER protects against cancer, aging, and neurodegeneration and takes place both in nuclei and mitochondria. More recently, an important role of uracil-DNA glycosylase UNG2 in adaptive immunity was revealed. Furthermore, other DNA glycosylases may have important roles in epigenetics, thus expanding the repertoire of BER proteins. PMID:23545420

  15. Laparoscopic versus open operation for perforated peptic ulcer in pediatric patients: A 10-year experience.

    PubMed

    Wong, Carol W Y; Chung, Patrick H Y; Tam, Paul K H; Wong, Kenneth K Y

    2015-12-01

    Perforated peptic ulcer (PPU) is a relatively uncommon condition in children. We aim to evaluate and compare the outcomes of laparoscopic omental patch repair versus open repair for PPU in pediatric patients. Children who underwent omental patch repair for PPU from 2004 to 2014 in our hospital were reviewed retrospectively. Patient demographics, perioperative as well as intraoperative details and surgical outcomes, were analyzed. Thirteen patients were identified, and all presented with abdominal pain. The median age of the study group was 14.9years (range 6.3 to 18.4years). Radiological evidence of pneumoperitoneum on erect chest x-ray (CXR) was found only in five patients (38.5%). None of the patients had a known history of peptic ulcer disease. Diagnosis other than PPU was made in five patients preoperatively. Laparoscopic repair was attempted in eight patients with one of them requiring conversion. There was no significant difference in patient demographics when compared with the open repair group. The perforation site was in the duodenum in 11 patients and in the antrum in two patients. The mean size of perforation was larger in the open repair group (p=0.005). Although the operating time was longer in the laparoscopic group (p=0.51), the length of hospital stay was significantly shorter (p=0.048). Only two patient diseases were Helicobacter pylori related. Clinical features of perforated peptic ulcer in children are different from adults. Risk factors are less frequently identified. Laparoscopic omental patch repair is a feasible surgical option and is associated with satisfactory outcomes in pediatric practice. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Patch-Augmented Rotator Cuff Repair and Superior Capsule Reconstruction

    PubMed Central

    Petri, M.; Greenspoon, J.A.; Moulton, S.G.; Millett, P.J.

    2016-01-01

    Background: Massive rotator cuff tears in active patients with minimal glenohumeral arthritis remain a particular challenge for the treating surgeon. Methods: A selective literature search was performed and personal surgical experiences are reported. Results: For patients with irreparable rotator cuff tears, a reverse shoulder arthroplasty or a tendon transfer are often performed. However, both procedures have rather high complication rates and debatable long-term results, particularly in younger patients. Therefore, patch-augmented rotator cuff repair or superior capsule reconstruction (SCR) have been recently developed as arthroscopically applicable treatment options, with promising biomechanical and early clinical results. Conclusion: For younger patients with irreparable rotator cuff tears wishing to avoid tendon transfers or reverse total shoulder arthroplasty, both patch-augmentation and SCR represent treatment options that may delay the need for more invasive surgery. PMID:27708733

  17. Bonding agents for portland cement concrete and mortar.

    DOT National Transportation Integrated Search

    1983-01-01

    Structural repairs of bridge piers and abutements require patching concrete : used depends upon the depth of the patch to be made. In some instances, the : use of a liquid bonding agent has been specified in the mixes as well as in a : grout scrubbed...

  18. A field investigation of concrete patches containing pyrament blended concrete.

    DOT National Transportation Integrated Search

    1994-01-01

    During roadway repairs, state highway officials try to minimize lane closure times. This reduces inconvenience to travelers, reduces traffic control needs, and helps minimize work zone accidents. For rapid repairs, materials that provide high early s...

  19. Portland cement concrete (PCC) partial-depth spall repair

    DOT National Transportation Integrated Search

    1999-11-01

    The primary aim of the partial-depth spall repair study was to determine the most effective and economical materials and procedures for placing quality, long-lasting partial-depth patches in jointed concrete pavements. A secondary objective of the st...

  20. Numerical simulations of mechanical properties of innovative pothole patching materials featuring high toughness, low viscosity nano-molecular resins

    NASA Astrophysics Data System (ADS)

    Yuan, K. Y.; Yuan, W.; Ju, J. W.; Yang, J. M.; Kao, W.; Carlson, L.

    2012-04-01

    As asphalt pavements age and deteriorate, recurring pothole repair failures and propagating alligator cracks in the asphalt pavements have become a serious issue to our daily life and resulted in high repairing costs for pavement and vehicles. To solve this urgent issue, pothole repair materials with superior durability and long service life are needed. In the present work, revolutionary pothole patching materials with high toughness, high fatigue resistance that are reinforced with nano-molecular resins have been developed to enhance their resistance to traffic loads and service life of repaired potholes. In particular, DCPD resin (dicyclopentadiene, C10H12) with a Rhuthinium-based catalyst is employed to develop controlled properties that are compatible with aggregates and asphalt binders. In this paper, a multi-level numerical micromechanics-based model is developed to predict the mechanical properties of these innovative nanomolecular resin reinforced pothole patching materials. Coarse aggregates in the finite element analysis are modeled as irregular shapes through image processing techniques and randomly-dispersed coated particles. The overall properties of asphalt mastic, which consists of fine aggregates, asphalt binder, cured DCPD and air voids are theoretically estimated by the homogenization technique of micromechanics. Numerical predictions are compared with suitably designed experimental laboratory results.

  1. Pipe inspection and repair system

    NASA Technical Reports Server (NTRS)

    Schempf, Hagen (Inventor); Mutschler, Edward (Inventor); Chemel, Brian (Inventor); Boehmke, Scott (Inventor); Crowley, William (Inventor)

    2004-01-01

    A multi-module pipe inspection and repair device. The device includes a base module, a camera module, a sensor module, an MFL module, a brush module, a patch set/test module, and a marker module. Each of the modules may be interconnected to construct one of an inspection device, a preparation device, a marking device, and a repair device.

  2. Repairing Hard-to-Reach Cracks in Heat-Exchanger Tubes

    NASA Technical Reports Server (NTRS)

    Mills, R. C., Sr.; Duesberg, J.

    1986-01-01

    Inaccessible leaks repaired from accessible side of tube. Fish-Mouth insert placed in cut in leaky heat-exchanger tube. Insert welded or brazed to tube, and remaining open area of cut patched. Method developed for repairing leaks in nozzle coolant tubes of Space Shuttle main engine. Method also used on other types of tubular heat exchangers.

  3. Salvage hypospadias repairs

    PubMed Central

    Sripathi, V.; Satheesh, M.; Shubha, K.

    2008-01-01

    Aim: Review of our experience and to develop an algorithm for salvage procedures in the management of hypospadias cripples and treatment of urethral strictures following hypospadias repair. Methods: This is a retrospective review of hypospadias surgeries over a 41-month period. Out of a total 168 surgeries, 20 were salvage/re-operative repairs. In three children a Duplay repair was feasible, while in four others a variety of single-stage repairs could be done. The repair was staged in seven children – buccal mucosal grafts (BMGs) in five, buccal mucosal tube in one, and skin graft in one. Five children with dense strictures were managed by dorsal BMG inlay grafting in one, vascularized tunical onlay grafting on the ventrum in one, and a free tunical patch in one. Three children were treated by internal urethrotomy and stenting for four weeks with a poor outcome. Results: The age of children ranged from 1.5–15 years (mean 4.5). Follow-up ranged from 3 months to 3.5 years. Excellent results were obtained in 10 children (50%) with a well-surfaced erect penis and a slit-like meatus. Glans closure could not be achieved and meatus was coronal in three. Two children developed fistulae following a Duplay repair and following a staged BMG. Three repairs failed completely – a composite repair broke down, a BMG tube stenosed with a proximal leak, and a stricture recurred with loss of a ventral free tunical graft. Conclusions: In salvage procedures performed on hypospadias cripples, a staged repair with buccal mucosa as an inlay in the first stage followed by tubularization 4–6 months later provides good results. A simple algorithm to plan corrective surgery in failed hypospadias cases and obtain satisfactory results is devised. PMID:20011495

  4. Salvage hypospadias repairs.

    PubMed

    Sripathi, V; Satheesh, M; Shubha, K

    2008-10-01

    Review of our experience and to develop an algorithm for salvage procedures in the management of hypospadias cripples and treatment of urethral strictures following hypospadias repair. This is a retrospective review of hypospadias surgeries over a 41-month period. Out of a total 168 surgeries, 20 were salvage/re-operative repairs. In three children a Duplay repair was feasible, while in four others a variety of single-stage repairs could be done. The repair was staged in seven children - buccal mucosal grafts (BMGs) in five, buccal mucosal tube in one, and skin graft in one. Five children with dense strictures were managed by dorsal BMG inlay grafting in one, vascularized tunical onlay grafting on the ventrum in one, and a free tunical patch in one. Three children were treated by internal urethrotomy and stenting for four weeks with a poor outcome. The age of children ranged from 1.5-15 years (mean 4.5). Follow-up ranged from 3 months to 3.5 years. Excellent results were obtained in 10 children (50%) with a well-surfaced erect penis and a slit-like meatus. Glans closure could not be achieved and meatus was coronal in three. Two children developed fistulae following a Duplay repair and following a staged BMG. Three repairs failed completely - a composite repair broke down, a BMG tube stenosed with a proximal leak, and a stricture recurred with loss of a ventral free tunical graft. In salvage procedures performed on hypospadias cripples, a staged repair with buccal mucosa as an inlay in the first stage followed by tubularization 4-6 months later provides good results. A simple algorithm to plan corrective surgery in failed hypospadias cases and obtain satisfactory results is devised.

  5. Is Decellularized Porcine Small Intestine Sub-mucosa Patch Suitable for Aortic Arch Repair?

    PubMed Central

    Corno, Antonio F.; Smith, Paul; Bezuska, Laurynas; Mimic, Branko

    2018-01-01

    Introduction: We reviewed our experience with decellularized porcine small intestine sub-mucosa (DPSIS) patch, recently introduced for congenital heart defects. Materials and Methods: Between 10/2011 and 04/2016 a DPSIS patch was used in 51 patients, median age 1.1 months (5 days to 14.5 years), for aortic arch reconstruction (45/51 = 88.2%) or aortic coarctation repair (6/51 = 11.8%). All medical records were retrospectively reviewed, with primary endpoints interventional procedure (balloon dilatation) or surgery (DPSIS patch replacement) due to patch-related complications. Results: In a median follow-up time of 1.5 ± 1.1 years (0.6–2.3years) in 13/51 patients (25.5%) a re-intervention, percutaneous interventional procedure (5/51 = 9.8%) or re-operation (8/51 = 15.7%) was required because of obstruction in the correspondence of the DPSIS patch used to enlarge the aortic arch/isthmus, with median max velocity flow at Doppler interrogation of 4.0 ± 0.51 m/s. Two patients required surgery after failed interventional cardiology. The mean interval between DPSIS patch implantation and re-intervention (percutaneous procedure or re-operation) was 6 months (1–17 months). While there were 3 hospital deaths (3/51 = 5.9%) not related to the patch implantation, no early or late mortality occurred for the subsequent procedure required for DPSIS patch interventional cardiology or surgery. The median max velocity flow at Doppler interrogation through the aortic arch/isthmus for the patients who did not require interventional procedure or surgery was 1.7 ± 0.57 m/s. Conclusions: High incidence of re-interventions with DPSIS patch for aortic arch and/or coarctation forced us to use alternative materials (homografts and decellularized gluteraldehyde preserved bovine pericardial matrix). PMID:29900163

  6. MDOT innovation leading to faster, longer-lasting pavement repairs : research spotlight.

    DOT National Transportation Integrated Search

    2015-01-01

    Current methods of patching pavement must evolve to meet increasing mobility demands. : To address this need, MDOT has been testing a new generation of rapid set full-depth : pavement repair materials. Initial results are promising. The new materials...

  7. Evaluation of a tissue-engineered bovine pericardial patch in paediatric patients with congenital cardiac anomalies: initial experience with the ADAPT-treated CardioCel(R) patch.

    PubMed

    Neethling, William M L; Strange, Geoff; Firth, Laura; Smit, Francis E

    2013-10-01

    This study evaluated the safety, efficacy and clinical performance of the tissue-engineered ADAPT® bovine pericardial patch (ABPP) in paediatric patients with a range of congenital cardiac anomalies. In this single-centre, prospective, non-randomized clinical study, paediatric patients underwent surgery for insertion of the ABPP. Primary efficacy measures included early (<30 day) morbidity; incidence of device-related complications; haemodynamic performance derived from echocardiography assessment at 6- and 12-month follow-up and magnetic resonance imaging findings in 10 randomly selected patients at 12 months. Secondary measures included device-handling characteristics; shape and sizing characteristics and perioperative implant complications. The Aristotle complexity scoring system was used to score the complexity level of all surgical procedures. Patients completing the 12-month study were eligible to enter a long-term evaluation study. Between April 2008 and September 2009, the ABPP was used in 30 paediatric patients. In the 30-day postoperative period, no graft-related morbidity was observed. In total, there were 5 deaths (2 in the 30-day postoperative period and 3 within the first 6 postoperative months). All deaths were deemed due to comorbid non-graft-related events. Echocardiography assessment at 6 and 12 months revealed intact anatomical and haemodynamically stable repairs without any visible calcification of the patch. Magnetic resonance imaging assessment in 10 patients at 12 months revealed no signs of calcification. Fisher's exact test demonstrated that patients undergoing more complex, higher risk surgical repairs (Aristotle complexity score >8) were significantly more likely to die (P = 0.0055, 58% survival compared with 100% survival for less complex surgical repairs). In 19 patients, echocardiographic data were available at 18-36 months with no evidence of device calcification, infection, thromboembolic events or device failure. This study demonstrates the safety and efficacy of this engineered bovine pericardial patch as a cardiovascular substitute for surgical repair of both simple and more complex congenital cardiac defects.

  8. Effectiveness of sacrificial anodes in high-resistivity shotcrete repairs.

    DOT National Transportation Integrated Search

    2005-01-01

    This study investigated the use of discrete sacrificial anodes to improve the durability and extend the life of a shotcrete patch repair in a column. Three columns were used in the investigation. In two columns, anodes were placed around the perimete...

  9. Analysis of repair and PCNA complex formation induced by ionizing radiation in human fibroblast cell lines.

    PubMed

    Karmakar, P; Balajee, A S; Natarajan, A T

    2001-05-01

    Proliferating cell nuclear antigen (PCNA), an auxiliary factor for DNA polymerase delta and epsilon, is involved in both DNA replication and repair. Previous studies in vitro have demonstrated the requirement of PCNA in the resynthesis step of nucleotide excision repair (NER) and base excision repair (BER). Using a native chromatin template isolated under near physiological conditions, we have analysed the involvement of PCNA in the BER pathway in different NER defective human cell lines. The repair sites and PCNA were visualized by indirect immunolabelling followed by fluorescence microscopy. The results indicate that exposure to X-rays triggers the induction of PCNA in all the three human fibroblast cell lines studied, namely normal, xeroderma pigmentosum group A (XP-A) and Cockayne syndrome group B (CS-B). In all the cell lines, induction of PCNA and repair patches occurred in a dose- and time-dependent fashion. Induction of repair patches in NER-deficient XP-A cells suggests that the X-ray-induced lesions are largely repaired via the BER pathway involving PCNA as one of the key components of this pathway. X-ray-induced repair synthesis was greatly inhibited by treatment of cells with DNA polymerase inhibitors aphidicolin and cytosine arabinoside. Interestingly, inhibition of repair resynthesis did not affect the intensity of PCNA staining in X-irradiated cells indicating that the PCNA may be required for the BER pathway at a step preceding the resynthesis step.

  10. Planar biaxial testing of heart valve cusp replacement biomaterials: Experiments, theory and material constants.

    PubMed

    Labrosse, Michel R; Jafar, Reza; Ngu, Janet; Boodhwani, Munir

    2016-11-01

    Aortic valve (AV) repair has become an attractive option to correct aortic insufficiency. Yet, cusp reconstruction with various cusp replacement materials has been associated with greater long-term repair failures, and it is still unknown how such materials mechanically compare with native leaflets. We used planar biaxial testing to characterize six clinically relevant cusp replacement materials, along with native porcine AV leaflets, to ascertain which materials would be best suited for valve repair. We tested at least six samples of: 1) fresh autologous porcine pericardium (APP), 2) glutaraldehyde fixed porcine pericardium (GPP), 3) St Jude Medical pericardial patch (SJM), 4) CardioCel patch (CC), 5) PeriGuard (PG), 6) Supple PeriGuard (SPG) and 7) fresh porcine AV leaflets (PC). We introduced efficient displacement-controlled testing protocols and processing, as well as advanced convexity requirements on the strain energy functions used to describe the mechanical response of the materials under loading. The proposed experimental and data processing pipeline allowed for a robust in-plane characterization of all the materials tested, with constants determined for two Fung-like hyperelastic, anisotropic strain energy models. Overall, CC and SPG (respectively PG) patches ranked as the closest mechanical equivalents to young (respectively aged) AV leaflets. Because the native leaflets as well as CC, PG and SPG patches exhibit significant anisotropic behaviors, it is suggested that the fiber and cross-fiber directions of these replacement biomaterials be matched with those of the host AV leaflets. The long-term performance of cusp replacement materials would ideally be evaluated in large animal models for AV disease and cusp repair, and over several months or more. Given the unavailability and impracticality of such models, detailed information on stress-strain behavior, as studied herein, and investigations of durability and valve dynamics will be the best surrogates, as they have been for prosthetic valves. Overall, comparison with Fig. 3 suggests that CC and SPG (respectively PG) patches may be the closest mechanical equivalents to young (respectively aged) AV leaflets. Interestingly, the thicknesses of these materials are close to those reported for porcine and younger human AV leaflets, which may facilitate surgical implantation, by contrast to the thinner APP which has poor handling qualities. Because the native leaflets as well as CC, PG and SPG patches exhibit anisotropic behaviors, from a mechanistic perspective alone, it stands to reason that cardiac surgeons should seek to intraoperatively match the fiber and cross-fiber directions of these replacement biomaterials with those of the repaired AV leaflets. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Structural Repair of Steel Piping by In-Situ Sleeving of Nanostructured Materials

    DOT National Transportation Integrated Search

    2009-06-03

    The focus of Task 1 is to demonstrate the repair of degraded pipeline steel using patches of high strength nanocrystalline metal. As mentioned in Bi-Monthly Research Progress Report #2, the cracking caused by corrosion damage in the steel pipe sectio...

  12. Selective versus routine patch metal allergy testing to select bar material for the Nuss procedure in 932 patients over 10years.

    PubMed

    Obermeyer, Robert J; Gaffar, Sheema; Kelly, Robert E; Kuhn, M Ann; Frantz, Frazier W; McGuire, Margaret M; Paulson, James F; Kelly, Cynthia S

    2018-02-01

    The aim of the study was to determine the role of patch metal allergy testing to select bar material for the Nuss procedure. An IRB-approved (11-04-WC-0098) single institution retrospective, cohort study comparing selective versus routine patch metal allergy testing to select stainless steel or titanium bars for Nuss repair was performed. In Cohort A (9/2004-1/2011), selective patch testing was performed based on clinical risk factors. In Cohort B (2/2011-9/2014), all patients were patch tested. The cohorts were compared for incidence of bar allergy and resultant premature bar loss. Risk factors for stainless steel allergy or positive patch test were evaluated. Cohort A had 628 patients with 63 (10.0%) selected for patch testing, while all 304 patients in Cohort B were tested. Over 10years, 15 (1.8%) of the 842 stainless steel Nuss repairs resulted in a bar allergy, and 5 had a negative preoperative patch test. The incidence of stainless steel bar allergy (1.8% vs 1.7%, p=0.57) and resultant bar loss (0.5% vs 1.3%, p=0.23) was not statistically different between cohorts. An allergic reaction to a stainless steel bar or a positive patch test was more common in females (OR=2.3, p<0.001) and patients with a personal (OR=24.8, p<0.001) or family history (OR=3.1, p<0.001) of metal sensitivity. Stainless steel bar allergies occur at a low incidence with either routine or selective patch metal allergy testing. If selective testing is performed, it is advisable in females and patients with a personal or family history of metal sensitivity. A negative preoperative patch metal allergy test does not preclude the possibility of a postoperative stainless steel bar allergy. Level III Treatment Study and Study of Diagnostic Test. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Repair process and a repaired component

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberts, III, Herbert Chidsey; Simpson, Stanley F.

    Matrix composite component repair processes are disclosed. The matrix composite repair process includes applying a repair material to a matrix composite component, securing the repair material to the matrix composite component with an external securing mechanism and curing the repair material to bond the repair material to the matrix composite component during the securing by the external securing mechanism. The matrix composite component is selected from the group consisting of a ceramic matrix composite, a polymer matrix composite, and a metal matrix composite. In another embodiment, the repair process includes applying a partially-cured repair material to a matrix composite component,more » and curing the repair material to bond the repair material to the matrix composite component, an external securing mechanism securing the repair material throughout a curing period, In another embodiment, the external securing mechanism is consumed or decomposed during the repair process.« less

  14. Field evaluation of corrosion inhibitors for concrete : interim report 2, evaluation of installation and initial condition of bridge repairs done with corrosion-inhibiting admixtures and topical treatments.

    DOT National Transportation Integrated Search

    1999-06-01

    Four bridge decks were overlayed and patched and one bridge pier was patched using concrete with and without corrosion inhibiting admixtures. Some concrete surfaces received topically applied corrosion-inhibiting treatments prior to placement of the ...

  15. Annexins in plasma membrane repair.

    PubMed

    Boye, Theresa Louise; Nylandsted, Jesper

    2016-10-01

    Disruption of the plasma membrane poses deadly threat to eukaryotic cells and survival requires a rapid membrane repair system. Recent evidence reveal various plasma membrane repair mechanisms, which are required for cells to cope with membrane lesions including membrane fusion and replacement strategies, remodeling of cortical actin cytoskeleton and vesicle wound patching. Members of the annexin protein family, which are Ca2+-triggered phospholipid-binding proteins emerge as important components of the plasma membrane repair system. Here, we discuss the mechanisms of plasma membrane repair involving annexins spanning from yeast to human cancer cells.

  16. The use of epoxy patch grafts for the repair of experimentally-created diaphragmatic defects in dogs.

    PubMed

    Matsumoto, H; Oguchi, Y; Miyake, Y; Masuda, Y; Masada, S; Kuno, Y; Shibahara, I; Takashima, K; Yamane, H; Yamagata, S; Noishiki, Y; Yamane, Y

    1996-07-01

    Canine pericardium which had been treated with polyepoxy compounds (Denacol EX-313) was used as a patch graft for the correction of experimentally-created diaphragmatic defects in five dogs belonging to the same litter. Clinical, macroscopic and histological examinations were conducted every month up to five months after suturing of the patch graft. Clinical examination of the patch graft showed no apparent abnormalities. Macroscopic examination conducted during autopsy showed that the patch graft maintained adequate elasticity for five months after suturing, the surface of the patch graft was covered with a thin membrane and neovascularization was observed. Histological examination showed that the surface of the patch graft was covered with a thin membrane. Inflammatory tissue reactions were observed at one month, but gradually decreased from the second month onwards. In addition, the patch graft had excellent tissue affinity.

  17. Rapid road repair vehicle

    DOEpatents

    Mara, Leo M.

    1998-01-01

    Disclosed is a rapid road repair vehicle capable of moving over a surface to be repaired at near normal posted traffic speeds to scan for and find an the high rate of speed, imperfections in the pavement surface, prepare the surface imperfection for repair by air pressure and vacuum cleaning, applying a correct amount of the correct patching material to effect the repair, smooth the resulting repaired surface, and catalog the location and quality of the repairs for maintenance records of the road surface. The rapid road repair vehicle can repair surface imperfections at lower cost, improved quality, at a higher rate of speed than was was heretofor possible, with significantly reduced exposure to safety and health hazards associated with this kind of road repair activities in the past.

  18. Rapid road repair vehicle

    DOEpatents

    Mara, L.M.

    1998-05-05

    Disclosed is a rapid road repair vehicle capable of moving over a surface to be repaired at near normal posted traffic speeds to scan for and find at the high rate of speed, imperfections in the pavement surface, prepare the surface imperfection for repair by air pressure and vacuum cleaning, applying a correct amount of the correct patching material to effect the repair, smooth the resulting repaired surface, and catalog the location and quality of the repairs for maintenance records of the road surface. The rapid road repair vehicle can repair surface imperfections at lower cost, improved quality, at a higher rate of speed than was not heretofor possible, with significantly reduced exposure to safety and health hazards associated with this kind of road repair activities in the past. 2 figs.

  19. Application of Circular Patch Plasty (Dor Procedure) or Linear Repair Techniques in the Treatment of Left Ventricular Aneurysms.

    PubMed

    Kaya, Ugur; Çolak, Abdurrahim; Becit, Necip; Ceviz, Munacettin; Kocak, Hikmet

    2018-01-01

    The aim of this study was to evaluate early clinical outcomes and echocardiographic measurements of the left ventricle in patients who underwent left ventricular aneurysm repair using two different techniques associated to myocardial revascularization. Eighty-nine patients (74 males, 15 females; mean age 58±8.4 years; range: 41 to 80 years) underwent post-infarction left ventricular aneurysm repair and myocardial revascularization performed between 1996 and 2016. Ventricular reconstruction was performed using endoventricular circular patch plasty (Dor procedure) (n=48; group A) or linear repair technique (n=41; group B). Multi-vessel disease in 55 (61.7%) and isolated left anterior descending (LAD) disease in 34 (38.2%) patients were identified. Five (5.6%) patients underwent aneurysmectomy alone, while the remaining 84 (94.3%) patients had aneurysmectomy with bypass. The mean number of grafts per patient was 2.1±1.2 with the Dor procedure and 2.9±1.3 with the linear repair technique. In-hospital mortality occurred in 4.1% and 7.3% in group A and group B, respectively (P>0.05). The results of our study demonstrate that post-infarction left ventricular aneurysm repair can be performed with both techniques with acceptable surgical risk and with satisfactory hemodynamic improvement.

  20. Structural Technology and Analysis Program (STAP) Delivery Order 0004: Durability Patch

    NASA Astrophysics Data System (ADS)

    Ikegami, Roy; Haugse, Eric; Trego, Angela; Rogers, Lynn; Maly, Joe

    2001-06-01

    Structural cracks in secondary structure, resulting from a high cycle fatigue (HCF) environment, are often referred to as nuisance cracks. This type of damage can result in costly inspections and repair. The repairs often do not last long because the repaired structure continues to respond in a resonant fashion to the environment. Although the use of materials for passive damping applications is well understood, there are few applications to high-cycle fatigue problems. This is because design information characterization temperature, resonant response frequency and strain levels are difficult to determine. The Durability Patch and Damage Dosimeter Program addressed these problems by: (1) Developing a damped repair design process which includes a methodology for designing the material and application characteristics required to optimally damp the repair. (2) Designing and developing a rugged, small, and lightweight data acquisition unit called the damage dosimeter. This is a battery operated, single board computer, capable of collecting three channels of strain and one channel of temperature, processing this data by user developed algorithms written in the C programming language, and storing the processed data in resident memory. The dosimeter is used to provide flight data needed to characterize the vibration environment. The vibration environment is then used to design the damping material characteristics and repair. The repair design methodology and dosimeter were demonstrated on B-52, C-130, and F-15 aircraft applications.

  1. Stem cells are dispensable for lung homeostasis but restore airways after injury.

    PubMed

    Giangreco, Adam; Arwert, Esther N; Rosewell, Ian R; Snyder, Joshua; Watt, Fiona M; Stripp, Barry R

    2009-06-09

    Local tissue stem cells have been described in airways of the lung but their contribution to normal epithelial maintenance is currently unknown. We therefore developed aggregation chimera mice and a whole-lung imaging method to determine the relative contributions of progenitor (Clara) and bronchiolar stem cells to epithelial maintenance and repair. In normal and moderately injured airways chimeric patches were small in size and not associated with previously described stem cell niches. This finding suggested that single, randomly distributed progenitor cells maintain normal epithelial homeostasis. In contrast we found that repair following severe lung injury resulted in the generation of rare, large clonal cell patches that were associated with stem cell niches. This study provides evidence that epithelial stem cells are dispensable for normal airway homeostasis. We also demonstrate that stem cell activation and robust clonal cellular expansion occur only during repair from severe lung injury.

  2. A New Absorbable Synthetic Substitute With Biomimetic Design for Dural Tissue Repair.

    PubMed

    Shi, Zhidong; Xu, Tao; Yuan, Yuyu; Deng, Kunxue; Liu, Man; Ke, Yiquan; Luo, Chengyi; Yuan, Tun; Ayyad, Ali

    2016-04-01

    Dural repair products are evolving from animal tissue-derived materials to synthetic materials as well as from inert to absorbable features; most of them lack functional and structural characteristics compared with the natural dura mater. In the present study, we evaluated the properties and tissue repair performance of a new dural repair product with biomimetic design. The biomimetic patch exhibits unique three-dimensional nonwoven microfiber structure with good mechanical strength and biocompatibility. The animal study showed that the biomimetic patch and commercially synthetic material group presented new subdural regeneration at 90 days, with low level inflammatory response and minimal to no adhesion formation detected at each stage. In the biological material group, no new subdural regeneration was observed and severe adhesion between the implant and the cortex occurred at each stage. In clinical case study, there was no cerebrospinal fluid leakage, and all the postoperation observations were normal. The biomimetic structure and proper rate of degradation of the new absorbable dura substitute can guide the meaningful reconstruction of the dura mater, which may provide a novel approach for dural defect repair. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  3. The biomechanical effects of polytetrafluoroethylene suture augmentations in lateral-row rotator cuff repairs in an ovine model.

    PubMed

    Beimers, Lijkele; Lam, Patrick H; Murrell, George A C

    2014-10-01

    This study investigated the biomechanical effects of expanded polytetrafluoroethylene (ePTFE) suture augmentation patches in rotator cuff repair constructs. The infraspinatus tendon in 24 cadaveric ovine shoulders was repaired using an inverted horizontal mattress suture with 2 knotless bone anchors (ArthroCare, Austin, TX, USA) in a lateral-row configuration. Four different repair groups (6 per group) were created: (1) standard repair using inverted horizontal mattress sutures, (2) repair with ePTFE suture augmentations on the bursal side of the tendon, (3) repair with ePTFE suture augmentations on the articular side, and, (4) repair with ePTFE suture augmentations on both sides of the tendon. Footprint contact pressure, stiffness, and the load to failure of the repair constructs were measured. Repairs with ePTFE suture augmentations on the bursal side exerted significantly more footprint contact pressure (0.40 ± 0.01 MPa) than those on the articular side (0.34 ± 0.02 MPa, P = .04) and those on both sides (0.33 ± 0.02 MPa, P = .01). At 15 degrees of abduction, ePTFE-augmented repairs on the bursal side had higher footprint contact pressure (0.26 ± 0.03 MPa) compared with standard repairs (0.15 ± 0.02 MPa, P = .01) and with ePTFE-augmented repairs on the articular side (0.18 ± 0.02 MPa, P = .03). The ePTFE-augmented repairs on the bursal side demonstrated significantly higher failure loads (178 ± 18 N) than standard repairs (120 ± 17 N, P = .04). Inverted horizontal mattress sutures augmented with ePTFE patches on the bursal side of the tendon enhanced footprint contact pressures and the ultimate load to failure of lateral-row rotator cuff repairs in an ovine model. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Long-term successful arthroscopic repair of large and massive rotator cuff tears with a functional and degradable reinforcement device.

    PubMed

    Proctor, Christopher S

    2014-10-01

    Rotator cuff repair is a procedure with varying outcomes, and there has been subsequent interest in devices that reinforce the repair and enhance structural and functional outcomes. The objective of this study was to determine these outcomes for arthroscopic repair of large and massive rotator cuff tears augmented with a synthetic absorbable mesh designed specifically for reinforcement of tendon repair by imaging and clinical assessments. Consecutive arthroscopic repairs were performed on 18 patients with large to massive rotator cuff tears by use of a poly-l-lactic acid synthetic patch as a reinforcement device and fixation with 4 sutures. Patients were assessed preoperatively and at 6 months, 12 months, and a mean of 42 months after surgery by the American Shoulder and Elbow Surgeons (ASES) shoulder score to evaluate clinical performance and at 12 months by ultrasound to assess structural repair. Ultrasound showed that 15 of 18 patients had intact rotator cuff repair at 12 months; at 42 months, an additional patient had a failed repair. Patients showed improvement in the ASES shoulder score from 25 preoperatively to 71 at 12 months and 70 at 42 months after surgery. Patients with intact rotator cuff (n = 14) at 42 months had an ASES shoulder score of 82. The poly-l-lactic acid bioabsorbable patch designed specifically to reinforce the surgical repair of tendons supported successful repair of large to massive rotator cuff tears in 83% of patients at 12 months after surgery and 78% of patients at 42 months after surgery, with substantial functional improvement. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  5. A rapid non-radioactive technique for measurement of repair synthesis in primary human fibroblasts by incorporation of ethynyl deoxyuridine (EdU).

    PubMed

    Limsirichaikul, Siripan; Niimi, Atsuko; Fawcett, Heather; Lehmann, Alan; Yamashita, Shunichi; Ogi, Tomoo

    2009-03-01

    Xeroderma pigmentosum (XP) is an autosomal recessive genetic disorder. Afflicted patients show extreme sun-sensitivity and skin cancer predisposition. XP is in most cases associated with deficient nucleotide excision repair (NER), which is the process responsible for removing photolesions from DNA. Measuring NER activity by nucleotide incorporation into repair patches, termed 'unscheduled DNA synthesis (UDS)', is one of the most commonly used assays for XP-diagnosis and NER research. We have established a rapid and accurate procedure for measuring UDS by replacement of thymidine with 5-ethynyl-2'-deoxyuridine (EdU). EdU incorporated into repair patches can be directly conjugated to fluorescent azide derivatives, thereby obviating the need for either radiolabeled thymidine or denaturation and antibody detection of incorporated bromodeoxyuridine (BrdU). We demonstrate that the EdU incorporation assay is compatible with conventional techniques such as immunofluorescent staining and labeling of cells with micro-latex beads. Importantly, we can complete the entire UDS assay within half a day from preparation of the assay coverslips; this technique may prove useful as a method for XP diagnosis.

  6. Marginal ulcer perforation: a single center experience.

    PubMed

    Natarajan, S K; Chua, D; Anbalakan, K; Shelat, V G

    2017-10-01

    Marginal ulcer (MU) is defined as ulcer on the jejunal side of the gastrojejunostomy (GJ) anastomosis. Most MUs are managed medically but those with complications like bleeding or perforation require intervention. It is recommended that GJ anastomosis be revised in patients with MU perforation (MUP). The aim of this case series is to study the clinical presentation and management of MUP. Three hundred and thirty-two patients who underwent emergency surgery for perforated peptic ulcer at a single center were studied over a period of 5 years. Nine patients (2.7 %) presented with MUP. GJ was previously done for either complicated peptic ulcer (n = 4) or for suspected gastric malignancy (n = 5). Two patients had previously completed H. pylori therapy. None of the patients presented with septic shock. MU was on the jejunal side of GJ in all patients. The median MUP size was 10 mm. Four patients (44.4 %) had omental patch repair, three (33.3 %) had primary closure, and one each had revision of GJ and jejunal serosal patch repair. There were no leaks, intra-abdominal abscess or reoperation and no malignancies. MUP patients do not present with septic shock. Omental patch repair or primary closure is sufficient enough. Revision of Billroth-II-GJ into Roux-en-Y-GJ is not mandatory.

  7. Laparoscopic versus Open Omental Patch Repair for Early Presentation of Perforated Peptic Ulcer: Matched Retrospective Cohort Study.

    PubMed

    Lee, Daniel Jin Keat; Ye, MaDong; Sun, Keith Haozhe; Shelat, Vishalkumar G; Koura, Aaryan

    2016-01-01

    Introduction. The aim of this study was to compare the outcomes between laparoscopic and open omental patch repair (LOPR versus OR) in patients with similar presentation of perforated peptic ulcer (PPU). The secondary aim was to evaluate the outcomes according to the severity of peritonitis. Methods. All patients who underwent omental patch repair at two university-affiliated institutes between January 2010 and December 2014 were reviewed. Matched cohort between LOPR and OR groups was achieved by only including patients that had ulcer perforation <2 cm in size and symptoms occurring <48 hours. Outcome measures were defined in accordance with length of stay (LOS), postoperative complications, and mortality. Results. 148 patients met the predefined inclusion criteria with LOPR performed in 40 patients. Outcome measures consistently support laparoscopic approach but only length of hospital stay (LOS) achieved statistical significance (LOPR 4 days versus OR 5 days, p < 0.01). In a subgroup analysis of patients with MPI score >21, LOPR is also shown to benefit, particularly resulting in significant shorter LOS (4 days versus 11 days, p < 0.01). Conclusion. LOPR offers improved short-term outcomes in patients who present within 48 hours and with perforation size <2 cm. LOPR also proved to be more beneficial in high MPI cases.

  8. Laparoscopic versus Open Omental Patch Repair for Early Presentation of Perforated Peptic Ulcer: Matched Retrospective Cohort Study

    PubMed Central

    Sun, Keith Haozhe; Koura, Aaryan

    2016-01-01

    Introduction. The aim of this study was to compare the outcomes between laparoscopic and open omental patch repair (LOPR versus OR) in patients with similar presentation of perforated peptic ulcer (PPU). The secondary aim was to evaluate the outcomes according to the severity of peritonitis. Methods. All patients who underwent omental patch repair at two university-affiliated institutes between January 2010 and December 2014 were reviewed. Matched cohort between LOPR and OR groups was achieved by only including patients that had ulcer perforation <2 cm in size and symptoms occurring <48 hours. Outcome measures were defined in accordance with length of stay (LOS), postoperative complications, and mortality. Results. 148 patients met the predefined inclusion criteria with LOPR performed in 40 patients. Outcome measures consistently support laparoscopic approach but only length of hospital stay (LOS) achieved statistical significance (LOPR 4 days versus OR 5 days, p < 0.01). In a subgroup analysis of patients with MPI score >21, LOPR is also shown to benefit, particularly resulting in significant shorter LOS (4 days versus 11 days, p < 0.01). Conclusion. LOPR offers improved short-term outcomes in patients who present within 48 hours and with perforation size <2 cm. LOPR also proved to be more beneficial in high MPI cases. PMID:27722200

  9. Long-term outcomes of reoperations following repair of partial atrioventricular septal defect.

    PubMed

    Buratto, Edward; Ye, Xin Tao; Bullock, Andrew; Kelly, Andrew; d'Udekem, Yves; Brizard, Christian P; Konstantinov, Igor E

    2016-08-01

    Partial atrioventricular septal defect (pAVSD) is repaired with excellent long-term survival. However, up to 25% of patients require reoperations. This study reviews results of reoperation following pAVSD repair at a single institution. From 1975 to 2012, 40 patients (16%, 40/246) underwent reoperation following pAVSD repair at the study institution. The data were retrospectively reviewed. The mean time to reoperation was 5.4 ± 5.8 years. The most common reoperations were left atrioventricular valve (LAVV) surgery (78%, 31/40) and resection of left ventricular outflow tract obstruction (20%, 8/40). The most common cause for LAVV surgery was regurgitation through the cleft (58%, 18/31), followed by central regurgitation (29%, 9/31). Most cases of LAVV regurgitation were treated by repair (77%, 24/31), rather than replacement (23%, 7/31). Since the introduction of a patch augmentation technique for LAVV repair in 1998, the rate of repair has increased from 54 to 94% (P = 0.012). The early mortality rate was 2.5% (1/40). The survival rate was 90% (95% CI: 76-96) at 10 years and 83% (95% CI: 60-94) at 20 years. The rate of freedom from further reoperation was 66% (95% CI: 46-80) at 10- and 20-year follow-up. The most common cause for reoperation following pAVSD repair was LAVV regurgitation through the LAVV cleft. Reoperation is performed with survival comparable to that of primary pAVSD repair, yet the rate of further reoperations remains high. The patch augmentation technique for LAVVR has significantly increased the rate of successful LAVV repair. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. Biocompatibility evaluation of cigarette and carbon papers used in repair of traumatic tympanic membrane perforations: experimental study.

    PubMed

    Altuntaş, Emine Elif; Sümer, Zeynep

    2013-01-01

    The purposes of this study were to investigate the biocompatibility of two different paper patches (carbon and cigarette papers) and compare the adhesion and proliferation features of L929 fibroblast cells by using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT Test) test and scanning electron microscopy (SEM). In this study, time-dependent cytotoxic effects of cigarette and carbon papers used in repairing small traumatic TM perforations were investigated in vitro by using MTT test. And also adhesion and spreading of cells over disk surface were observed by SEM. Cytotoxicity test carried out by MTT analysis on leakage products collected from two types of paper patches at the end of 24 and 48 h revealed no cytotoxicity (P > 0.05). In SEM studies, it was observed that cells started to proliferate over disk surface as a result of 48-h incubation, and SEM revealed that the cell proliferation over cigarette paper was more compared to the one over carbon paper. We believe that this is the first study where biocompatibility and adhesion features of carbon and cigarette paper have been studied by using L929 fibroblast cell culture. As a result, biocompatibility of cigarette paper and also whether cigarette paper was superior to carbon paper in cell attachment and biocompatibility were studied. It was found, by MTT test and SEM test, that cigarette paper had a higher biocompatibility and cell attachment, and thus cigarette paper should be the patch to be preferred in cases where TM perforations are repaired by paper-patch method.

  11. Implantation of the Medtronic Harmony Transcatheter Pulmonary Valve Improves Right Ventricular Size and Function in an Ovine Model of Postoperative Chronic Pulmonary Insufficiency.

    PubMed

    Schoonbeek, Rosanne C; Takebayashi, Satoshi; Aoki, Chikashi; Shimaoka, Toru; Harris, Matthew A; Fu, Gregory L; Kim, Timothy S; Dori, Yoav; McGarvey, Jeremy; Litt, Harold; Bouma, Wobbe; Zsido, Gerald; Glatz, Andrew C; Rome, Jonathan J; Gorman, Robert C; Gorman, Joseph H; Gillespie, Matthew J

    2016-10-01

    Pulmonary insufficiency is the nexus of late morbidity and mortality after transannular patch repair of tetralogy of Fallot. This study aimed to establish the feasibility of implantation of the novel Medtronic Harmony transcatheter pulmonary valve (hTPV) and to assess its effect on pulmonary insufficiency and ventricular function in an ovine model of chronic postoperative pulmonary insufficiency. Thirteen sheep underwent baseline cardiac magnetic resonance imaging, surgical pulmonary valvectomy, and transannular patch repair. One month after transannular patch repair, the hTPV was implanted, followed by serial magnetic resonance imaging and computed tomography imaging at 1, 5, and 8 month(s). hTPV implantation was successful in 11 animals (85%). There were 2 procedural deaths related to ventricular fibrillation. Seven animals survived the entire follow-up protocol, 5 with functioning hTPV devices. Two animals had occlusion of hTPV with aneurysm of main pulmonary artery. A strong decline in pulmonary regurgitant fraction was observed after hTPV implantation (40.5% versus 8.3%; P=0.011). Right ventricular end diastolic volume increased by 49.4% after transannular patch repair (62.3-93.1 mL/m 2 ; P=0.028) but was reversed to baseline values after hTPV implantation (to 65.1 mL/m 2 at 8 months, P=0.045). Both right ventricular ejection fraction and left ventricular ejection fraction were preserved after hTPV implantation. hTPV implantation is feasible, significantly reduces pulmonary regurgitant fraction, facilitates right ventricular volume improvements, and preserves biventricular function in an ovine model of chronic pulmonary insufficiency. This percutaneous strategy could potentially offer an alternative for standard surgical pulmonary valve replacement in dilated right ventricular outflow tracts, permitting lower risk, nonsurgical pulmonary valve replacement in previously prohibitive anatomies. © 2016 American Heart Association, Inc.

  12. Atelocollagen Enhances the Healing of Rotator Cuff Tendon in Rabbit Model.

    PubMed

    Suh, Dong-Sam; Lee, Jun-Keun; Yoo, Ji-Chul; Woo, Sang-Hun; Kim, Ga-Ram; Kim, Ju-Won; Choi, Nam-Yong; Kim, Yongdeok; Song, Hyun-Seok

    2017-07-01

    Failure of rotator cuff healing is a common complication despite the rapid development of surgical repair techniques for the torn rotator cuff. To verify the effect of atelocollagen on tendon-to-bone healing in the rabbit supraspinatus tendon compared with conventional cuff repair. Controlled laboratory study. A tear of the supraspinatus tendon was created and repaired in 46 New Zealand White rabbits. They were then randomly allocated into 2 groups (23 rabbits per group; 15 for histological and 8 for biomechanical test). In the experimental group, patch-type atelocollagen was implanted between bone and tendon during repair; in the control group, the torn tendon was repaired without atelocollagen. Each opposite shoulder served as a sham (tendon was exposed only). Histological evaluation was performed at 4, 8, and 12 weeks. Biomechanical tensile strength was tested 12 weeks after surgery. Histological evaluation scores of the experimental group (4.0 ± 1.0) were significantly superior to those of the control group (7.7 ± 2.7) at 12 weeks ( P = .005). The load to failure was significantly higher in the experimental group (51.4 ± 3.9 N) than in the control group (36.4 ± 5.9 N) ( P = .001). Histological and biomechanical studies demonstrated better results in the experimental group using atelocollagen in a rabbit model of the supraspinatus tendon tear. Atelocollagen patch could be used in the cuff repair site to enhance healing.

  13. Long-term outcome of large artificial patch aortic repair for diffuse stenosis in Williams syndrome.

    PubMed

    Sughimoto, Koichi; Takahara, Yoshiharu; Mogi, Kenji; Sakurai, Manabu; Aoki, Chikashi

    2010-10-01

    There have been only a few reports concerning the long-term results of a surgical procedure using a large artificial patch for patients with Williams syndrome. Twelve years have passed since a patient with William's syndrome underwent a surgery with a patch angioplasty for the diffuse supravalvular aortic stenosis and deformities of the neck branch arteries. The patient had a well-balanced aortic growth without stenotic or aneurysmal changes, which was confirmed during the time of the second surgery when replacing the mitral valve. This technique of using a large patch has proven to be safe for Williams syndrome patients with diffuse supravalvular aortic stenosis in the long term.

  14. In vivo experimental study on laser welded ICG-loaded chitosan patches for vessel repair

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Matteini, Paolo; Esposito, Giuseppe; Albanese, Alessio; Puca, Alfredo; Maira, Giulio; Rossi, Giacomo; Pini, Roberto

    2011-03-01

    Laser welding of microvessels provides several advantages over conventional suturing techniques: surgical times reduction, vascular healing process improvement, tissue damage reduction. We present the first application of biopolymeric patches in an in vivo laser assisted procedure for vessel repair. The study was performed in 20 New Zealand rabbits. After anesthesia, a 3-cm segment of the right common carotid artery was exposed and clamped proximally and distally. A linear lesion 3 mm in length was carried out. We used a diode laser emitting at 810 nm and equipped with a 300 μm diameter optical fiber. To close the cut, ICG-loaded chitosan films were prepared: chitosan is characterized by biodegradability, biocompatibility, antimicrobial, haemostatic and wound healing-promoting activity. ICG is an organic chromophore commonly used in the laser welding procedures to mediate the photothermal conversion at the basis of the welding effect. The membranes were used to wrap the whole length of the cut, and then they were welded in the correct position by delivering single laser spots to induce local patch/tissue adhesion. The result is an immediate closure of the wound, with no bleeding at clamps release. The animals were observed during follow-up and sacrificed after 2, 7, 30 and 90 days. All the repaired vessels were patent, no bleeding signs were documented. The carotid samples underwent histological examinations. The advantages of the proposed technique are: simplification of the surgical procedure and shortening of the operative time; good strength of the vessel repair; decreased foreign-body reaction, reduced inflammatory response and improved vascular healing process.

  15. Species composition and structure of regenerated and remnant forest patches within an urban landscape

    Treesearch

    Wayne C. Zipperer

    2002-01-01

    Regenerated and remnant forest patches were inventoried in Syracuse, New York, USA to determine differences in structure, species composition, human disturbances, and landscape context. Patches had similar mean stem diameter, total stem density, and total basal areas, but differed with respect to diameter distribution, disturbance regime, landscape context, and...

  16. Fetoscopic single-layer repair of open spina bifida using a cellulose patch: preliminary clinical experience.

    PubMed

    Pedreira, Denise A L; Zanon, Nelci; de Sá, Renato A M; Acacio, Gregório L; Ogeda, Edilson; Belem, Teresa M L O U; Chmait, Ramen H; Kontopoulos, Eftichia; Quintero, Ruben A

    2014-11-01

    To report our preliminary clinical experience in the antenatal correction of open spina bifida (OSB) using a fetoscopic approach and a simplified closure technique. Four fetuses with lumbar-sacral defects were operated in utero from 25 to 27 weeks. Surgeries were performed percutaneously under general anesthesia using three trocars and partial carbon dioxide insufflation. After dissection of the neural placode, the surrounding skin was closed over a cellulose patch using a single continuous stitch. Surgical closure was successful in three of the four cases. All successful cases showed improvement of the hindbrain herniation and no neonatal neurosurgical repair was required in two cases. Delivery occurred between 31 and 33 weeks, and no fetal or neonatal deaths occurred. Ventriculoperitoneal shunting was not needed in two out of the 3 successful cases. Our preliminary experience suggests that definitive fetoscopic repair of OSB is feasible using our innovative surgical technique. A phase I trial for the fetoscopic correction of OSB with this technique is currently being conducted.

  17. Iatrogenic Aortic Valve Perforation after Ventricular Septal Defect Repair

    PubMed Central

    Ren, Chonglei; Wang, Mingyan; Wang, Yao; Gao, Changqing

    2017-01-01

    Iatrogenic aortic valve (AV) perforation during non-aortic cardiac operations is a rare complication. The suture-related inadvertent injury to an AV leaflet can produce leaflet perforation with aortic regurgitation after ventricular septal defect repair (VSDR). We report three consecutive patients who had iatrogenic aortic leaflet perforation during VSDR in other hospitals and referred to our hospital for reoperation. In all three cases, the perforated AV leaflets were preserved and repaired by autologous pericardial patch or direct local closure. PMID:29057770

  18. Effect of an Extra Hydrophobic Resin Layer on Repair Shear Bond Strength of a Silorane-Based Composite Resin

    PubMed Central

    Mohammadi, Narmin; Bahari, Mahmoud; Kimyai, Soodabeh; Rahbani Nobar, Behnam

    2015-01-01

    Objectives: Composite repair is a minimally invasive and conservative approach. This study aimed to evaluate the effect of an additional hydrophobic resin layer on the repair shear bond strength of a silorane-based composite repaired with silorane or methacrylate-based composite. Materials and Methods: Sixty bar-shaped composite blocks were fabricated and stored in saline for 72 hours. The surface of the samples were roughened by diamond burs and etched with phosphoric acid; then, they were randomly divided into three groups according to the repairing process: Group 1: Silorane composite-silorane bonding agent-silorane composite; group 2: Silorane composite-silorane bonding agent-hydrophobic resin-silorane composite, and group 3: Silorane composite-silorane bonding agent-hydrophobic resin methacrylate-based composite. Repairing composite blocks measured 2.5×2.5×5mm. After repairing, the samples were stored in saline for 24 hours and thermocycled for 1500 cycles. The repair bond strength was measured at a strain rate of 1mm/min. Twenty additional cylindrical composite blocks (diameter: 2.5mm, height: 6mm) were also fabricated for measuring the cohesive strength of silorane-based composite. The data were analyzed using One-way ANOVA and the post hoc Tukey’s test (α=0.05). Results: Cohesive bond strength of silorane composite was significantly higher than the repair bond strengths in other groups (P<0.001). The repair bond strength of group 3 was significantly higher than that of group 1 (P=0.001). Conclusion: Application of an additional hydrophobic resin layer for repair of silorane-based composite with a methacrylate-based composite enhanced the repair shear bond strength. PMID:27559348

  19. Manufacturing and testing of active composite panels with embedded piezoelectric sensors and actuators: wires out by molded-in holes

    NASA Astrophysics Data System (ADS)

    Ghasemi-Nejhad, Mehrdad N.; Pourjalali, Saeid

    2003-08-01

    This work presents manufacturing and testing of active composite panels (ACPs) with embedded piezoelectric sensors and actuators. The composite material employed here is a plain weave carbon epoxy prepreg fabric with about 0.33 mm ply thickness. The piezoelectric patches employed here are Continuum Control Corporation, CCC, (recently Continuum Photonics, Inc) active fiber composite patches with 0.33 mm thickness, i.e. close to the composite ply thickness. Composite cut-out layers are used to fill the space around the embedded piezoelectric patches to minimize the problems associated with ply drops in composites. The piezoelectric patches were embedded inside the composite laminate. High-temperature wires were soldered to the piezoelectric leads, insulated from the carbon substructure by high-temperature materials, and were taken out of the composite laminates employing a molded-in hole technique that reduces the stress concentration as opposed to a drilled hole, and thereby enhancing the performance of the composite structure. The laminated ACP"s were co-cured inside an autoclave employing the cure cycle recommended by the composite material supplier. The curie temperature of the embedded piezoelectric patches should be well above the curing temperature of the composite materials as was the case here. The manufactured ACP beams and plates were trimmed and then tested for their functionality. Vibration suppression as well as simultaneous vibration suppression and precision positioning tests, using PID control as well as Hybrid Adaptive Control techniques were successfully conducted on the manufactured ACP beams and their functionality were demonstrated. Recommendations on the use of this embedding technique for ACPs are provided.

  20. Outcomes of aortopulmonary window repair in children: 33 years of experience.

    PubMed

    Naimo, Phillip S; Yong, Matthew S; d'Udekem, Yves; Brizard, Christian P; Kelly, Andrew; Weintraub, Robert; Konstantinov, Igor E

    2014-11-01

    The purpose of this study was to assess the outcomes of children undergoing repair of aortopulmonary window (APW). We conducted a retrospective review of all children (n=43) who underwent surgical repair of APW between 1980 and 2013. Median age at surgery was 40 days (range, 13 to 125). Simple APW was present in 15 of 43 patients (35%), and 28 of 43 patients (65%) patients had concomitant cardiovascular anomalies. The aorta was repaired by direct suturing in 36 patients (84%) patients and patching in 7 patients (16%). The main pulmonary artery was repaired by direct suturing in 22 patients (51%) patients and by patching in 21 (49%). Cardiopulmonary bypass was used in 42 of the 43 patients (97.7%). Single-staged repair of concomitant cardiovascular anomalies was undertaken in 26 of 28 patients (93%). Only 2 of the 28 patients (7%) underwent repair of interrupted aortic arch before APW repair. Operative mortality was 6.7% (1 of 15 patients) among patients with simple APW and 18% (5 of 28 patients) among patients with concomitant anomalies. Operative weight less than 2.5 kg was associated with mortality on univariable analysis (p=0.02). Median follow-up was 10.1 years (range, 0.17 to 24.2). There were no late deaths. Overall survival was 86% (95% confidence interval: 71.3 to 94.2) at 10 years. Freedom from reoperation was 95.3% (95% confidence interval: 86.2 to 99.9) at 10 years. At last follow-up, all patients were in New York Heart Association functional class I/II. Survival beyond discharge from the hospital is associated with excellent outcomes. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. No patch technique for complete atrioventricular canal repair.

    PubMed

    Aramendi, José Ignacio; Rodriguez, Miguel Angel; Luis, Teresa; Voces, Roberto

    2006-08-01

    We describe our initial experience with a new technique, consisting in direct closure of the ventricular septal defect component of the AV canal, by directly attaching the common bridging leaflets to the crest of the ventricular septum with interrupted sutures. After closure of the cleft, the ostium primum defect was closed with a running suture suturing the border of the septum primum to the newly created AV valve annulus. Three patients were operated upon. There was no mortality. Mean ischemic time was 39 min and mean pump time 77 min. All patients remained in sinus rhythm. At follow-up only trivial or mild mitral regurgitation was observed. This new technique permits the repair of complete AV canal without the need for any patch. It is fast, simple and reproducible.

  2. Conjunctival inclusion cyst following repair of tube erosion in a child with aphakic glaucoma, leading to endophthalmitis.

    PubMed

    Roy, Avik Kumar; Senthil, Sirisha

    2015-01-01

    Glaucoma in aphakia is a major long term complication following congenital cataract surgery. Implantation of glaucoma drainage device provides an effective approach to manage refractory paediatric glaucoma. However implant surgery in young individuals is not free of complications. The prompt detection and management of tube erosion is of utmost importance to prevent devastating sequel of endophthalmitis. Implantation cyst following repair of tube erosion has not been reported so far. This case illustrates the rare occurrence of inclusion cyst following repair of tube erosion, the possible causes and its consequences. A 2-year-old child with aphakia developed intractable glaucoma. Following a failed glaucoma filtering surgery he underwent sequential Ahmed Glaucoma Valve implantation in both the eyes. Six weeks following right eye surgery, the child presented with conjunctival erosion overlying the tube, which was treated with scleral patch graft and conjunctival advancement. One month after the repair of tube erosion, the child presented with implantation cyst under the scleral patch graft, which was treated by drainage with a 29G needle. The child presented with endophthalmitis of his right eye following an episode of bilateral conjunctivitis. This was managed by an emergency pars plana vitrectomy, intraocular antibiotics and tube excision. At the last follow up visit, the IOP was 20 mmHg with 2 topical antiglaucoma medications in the right eye following a trans scleral photocoagulation. Lifelong careful follow-up of paediatric eyes with implant surgery is mandatory to look for complication such as tube erosion. It is important to place additional sutures to secure the patch graft during implantation of glaucoma drainage devices in children to prevent graft displacement and consequent tube erosion. During repair of tube erosion, it is crucial to remove all the conjunctival epithelium around the tube, thus not to incorporate epithelial tissue within the surgical wound.

  3. Repair of tetralogy of Fallot associated with atrioventricular septal defect.

    PubMed

    Tláskal, T; Hucín, B; Kostelka, M; Chaloupecký, V; Marek, J; Tax, P; Janouàek, J; Kuèera, V; Hruda, J; Reich, O; Skovránek, J

    1998-01-01

    Tetralogy of Fallot, when associated with atrioventricular septal defect permitting shunting at ventricular level, represents a complex cyanotic congenital malformation. Experience with surgical repair is limited, and results vary considerably. Between 1984 and 1996, we repaired 14 consecutive patients with this combination seen in our center. Their ages ranged from 8 months to 21 years (median 7.4 years). Six (42.9%) had Down's syndrome. In eight patients the correct diagnosis was made using echocardiography alone. In the remaining six patients, who had previously-constructed arterial shunts and/or suspected pulmonary arterial stenosis, catheterization and angiocardiography were also performed. The repair consisted of double patch closure of the septal defect, reconstruction of two atrioventricular orifices, and relief of pulmonary stenosis at all levels. In five patients with a hypoplastic pulmonary trunk, a monocusp transannular patch (four patients) or an allograft (one patient) was used for restoration of continuity from the right ventricle to the pulmonary arteries. Patch enlargement of one or both pulmonary arteries was necessary in five patients. One patient (7.1%) died early, and another late. The twelve surviving (85.8%) patients have been followed for 1.2-12.5 years after surgery (median 4.9 years, mean 5.9+/-3.9 years). During the follow-up, reoperation was necessary for repair of residual ventricular septal defect and pulmonary regurgitation in two patients, and closure of an atrial septal defect and alteration to left atrioventricular valvar regurgitation in one patient. Seven patients are in class I of the New York Heart Association, four in class II, and one in class III. Tetralogy of Fallot associated with atrioventricular septal defect can be corrected with low mortality and good long-term results. Residual lesions, however, have a tendency to progress, especially when seen in combination. After surgery, all patients need long-term close follow-up.

  4. Long-term results of pulmonary valve annular enlargement with valve repair in tetralogy of Fallot.

    PubMed

    Kim, Hyungtae; Sung, Si Chan; Choi, Kwang Ho; Lee, Hyoung Doo; Kim, Geena; Ko, Hoon; Lee, Young Seok

    2018-06-01

    We adopted an operative technique of pulmonary valve (PV) annular enlargement with valve repair in tetralogy of Fallot (TOF) correction to reduce postoperative pulmonary regurgitation (PR) 16 years ago. Here, we have evaluated the long-term results. Between April 2000 and August 2005, 43 patients (26 men) with tetralogy of Fallot with pulmonary stenosis underwent PV annular enlargement with valve repair. The median age and body weight at the time of surgery were 14 months and 10.2 kg, respectively. There was no operative mortality. Mean postoperative PR grade at discharge was 0.93 ± 0.40 (none or trivial in 10 patients, mild in 27 patients, mild to moderate in 5 patients and moderate in 1 patient), and the mean postoperative pressure gradient across PV was 13.0 ± 10.9 mmHg. The mean follow-up duration was 131.9 ± 42.9 months. During follow-up, 1 reoperation was performed for residual ventricular septal defect. The mean PR grade at the last follow-up echocardiography was 1.59 ± 0.60 (mild in 17 patients, mild to moderate in 8 patients, moderate in 14 patients, moderate to severe in 1 patient and severe in 3 patients), and the mean pressure gradient was 22.7 ± 9.9 mmHg. We have compared the incidence of moderate or more PR with the incidence of patients who underwent simple transannular patch enlargement through propensity score matching. The PV repair group had a lower incidence of moderate or more PR compared with the simple transannular patch group (40% vs 68%, P = 0.04). PV annular enlargement with valve repair has reasonable long-term results and yields a lower long-term incidence of significant PR compared with the simple transannular patch enlargement technique.

  5. Turbine repair process, repaired coating, and repaired turbine component

    DOEpatents

    Das, Rupak; Delvaux, John McConnell; Garcia-Crespo, Andres Jose

    2015-11-03

    A turbine repair process, a repaired coating, and a repaired turbine component are disclosed. The turbine repair process includes providing a turbine component having a higher-pressure region and a lower-pressure region, introducing particles into the higher-pressure region, and at least partially repairing an opening between the higher-pressure region and the lower-pressure region with at least one of the particles to form a repaired turbine component. The repaired coating includes a silicon material, a ceramic matrix composite material, and a repaired region having the silicon material deposited on and surrounded by the ceramic matrix composite material. The repaired turbine component a ceramic matrix composite layer and a repaired region having silicon material deposited on and surrounded by the ceramic matrix composite material.

  6. Integration of stem cell-derived exosomes with in situ hydrogel glue as a promising tissue patch for articular cartilage regeneration.

    PubMed

    Liu, Xiaolin; Yang, Yunlong; Li, Yan; Niu, Xin; Zhao, Bizeng; Wang, Yang; Bao, Chunyan; Xie, Zongping; Lin, Qiuning; Zhu, Linyong

    2017-03-30

    The regeneration of articular cartilage, which scarcely shows innate self-healing ability, is a great challenge in clinical treatment. Stem cell-derived exosomes (SC-Exos), an important type of extracellular nanovesicle, exhibit great potential for cartilage regeneration to replace stem cell-based therapy. Cartilage regeneration often takes a relatively long time and there is currently no effective administration method to durably retain exosomes at cartilage defect sites to effectively exert their reparative effect. Therefore, in this study, we exploited a photoinduced imine crosslinking hydrogel glue, which presents excellent operation ability, biocompatibility and most importantly, cartilage-integration, as an exosome scaffold to prepare an acellular tissue patch (EHG) for cartilage regeneration. It was found that EHG can retain SC-Exos and positively regulate both chondrocytes and hBMSCs in vitro. Furthermore, EHG can integrate with native cartilage matrix and promote cell deposition at cartilage defect sites, finally resulting in the promotion of cartilage defect repair. The EHG tissue patch therefore provides a novel, cell-free scaffold material for wound repair.

  7. Esophageal replacement by hydroxylated bacterial cellulose patch in a rabbit model.

    PubMed

    Zhu, Changlai; Liu, Fang; Qian, Wenbo; Wang, Yingjie; You, Qingsheng; Zhang, Tianyi; Li, Feng

    2015-01-01

    To repair esophageal defects by hydroxylated and kombucha-synthesized bacterial cellulose (HKBC) patch in a rabbit model. Semicircular esophageal defects 1 cm in length of the cervical esophagus were initially created in 18 Japanese big-ear rabbits and then repaired with HKBC patch grafts. The clinical outcomes including survival rate, weight change, food intake, and hematological and radiologic evaluation were observed. After X-ray evaluation, the rabbits were sacrificed sequentially at 1, 3, and 6 months for histopathologic analysis with light microscopy and scanning electron microscopy. Survival rate during the first month was 88.9% (n = 16). Two rabbits died from anastomotic leakage during the entire follow-up. Postoperatively, feeding function and body weight were gradually restored in the surviving animals. No hematological abnormalities were found, and no obvious anastomotic leakage, stenosis, or obstruction was observed under X-ray examination. The histopathologic results showed a progressive regeneration of the esophagus in the graft area, where the neo-esophagus tissue had characteristics similar to native esophageal tissue after 3 months of surgery. HKBC is beneficial for esophageal tissue regeneration and may be a promising material for esophageal reconstruction.

  8. New Technologies for Surgery of the Congenital Cardiac Defect

    PubMed Central

    Kalfa, David; Bacha, Emile

    2013-01-01

    The surgical repair of complex congenital heart defects frequently requires additional tissue in various forms, such as patches, conduits, and valves. These devices often require replacement over a patient’s lifetime because of degeneration, calcification, or lack of growth. The main new technologies in congenital cardiac surgery aim at, on the one hand, avoiding such reoperations and, on the other hand, improving long-term outcomes of devices used to repair or replace diseased structural malformations. These technologies are: 1) new patches: CorMatrix® patches made of decellularized porcine small intestinal submucosa extracellular matrix; 2) new devices: the Melody® valve (for percutaneous pulmonary valve implantation) and tissue-engineered valved conduits (either decellularized scaffolds or polymeric scaffolds); and 3) new emerging fields, such as antenatal corrective cardiac surgery or robotically assisted congenital cardiac surgical procedures. These new technologies for structural malformation surgery are still in their infancy but certainly present great promise for the future. But the translation of these emerging technologies to routine health care and public health policy will also largely depend on economic considerations, value judgments, and political factors. PMID:23908869

  9. Comparison of a novel bone-tendon allograft with a human dermis-derived patch for repair of chronic large rotator cuff tears using a canine model.

    PubMed

    Smith, Matthew J; Cook, James L; Kuroki, Keiichi; Jayabalan, Prakash S; Cook, Cristi R; Pfeiffer, Ferris M; Waters, Nicole P

    2012-02-01

    This study tested a bone-tendon allograft versus human dermis patch for reconstructing chronic rotator cuff repair by use of a canine model. Mature research dogs (N = 15) were used. Radiopaque wire was placed in the infraspinatus tendon (IST) before its transection. Three weeks later, radiographs showed IST retraction. Each dog then underwent 1 IST treatment: debridement (D), direct repair of IST to bone with a suture bridge and human dermis patch augmentation (GJ), or bone-tendon allograft (BT) reconstruction. Outcome measures included lameness grading, radiographs, and ultrasonographic assessment. Dogs were killed 6 months after surgery and both shoulders assessed biomechanically and histologically. BT dogs were significantly (P = .01) less lame than the other groups. BT dogs had superior bone-tendon, tendon, and tendon-muscle integrity compared with D and GJ dogs. Biomechanical testing showed that the D group had significantly (P = .05) more elongation than the other groups whereas BT had stiffness and elongation characteristics that most closely matched normal controls. Radiographically, D and GJ dogs showed significantly more retraction than BT dogs (P = .003 and P = .045, respectively) Histologically, GJ dogs had lymphoplasmacytic infiltrates, tendon degeneration and hypocellularity, and poor tendon-bone integration. BT dogs showed complete incorporation of allograft bone into host bone, normal bone-tendon junctions, and well-integrated allograft tendon. The bone-tendon allograft technique re-establishes a functional IST bone-tendon-muscle unit and maintains integrity of repair in this model. Clinical trials using this bone-tendon allograft technique are warranted. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  10. Biodegradable materials for surgical management of infective endocarditis: new solution or a dead end street?

    PubMed

    Myers, Patrick O; Cikirikcioglu, Mustafa; Kalangos, Afksendiyos

    2014-08-03

    One third of patients with infective endocarditis will require operative intervention. Given the superiority of valve repair over valve replacement in many indications other than endocarditis, there has been increasing interest and an increasing number of reports of excellent results of valve repair in acute infective endocarditis. The theoretically ideal material for valve repair in this setting is non-permanent, "vanishing" material, not at risk of seeding or colonization. The goal of this contribution is to review currently available data on biodegradable materials for valve repair in infective endocarditis. Rigorous electronic and manual literature searches were conducted to identify reports of biodegradable materials for valve repair in infective endocarditis. Articles were identified in electronic database searches of Medline, Embase and the Cochrane Library, using a predetermined search strategy. 49 manuscripts were included in the review. Prosthetic materials needed for valve repair can be summarized into annuloplasty rings to remodel the mitral or tricuspid annulus, and patch materials to replace resected valvar tissue. The commercially available biodegradable annuloplasty ring has shown interesting clinical results in a single-center experience; however further data is required for validation and longer follow-up. Unmodified extra-cellular matrix patches, such as small intestinal submucosa, have had promising initial experimental and clinical results in non-infected valve repair, although in valve repair for endocarditis has been reported in only one patient, and concerns have been raised regarding their mechanical stability in an infected field. These evolving biodegradable devices offer the potential for valve repair with degradable materials replaced with autologous tissue, which could further improve the results of valve repair for infective endocarditis. This is an evolving field with promising experimental or initial clinical results, however long-term outcomes are lacking and further data is necessary to validate this theoretically interesting approach to infective endocarditis.

  11. Biodegradable materials for surgical management of infective endocarditis: new solution or a dead end street?

    PubMed Central

    2014-01-01

    Background One third of patients with infective endocarditis will require operative intervention. Given the superiority of valve repair over valve replacement in many indications other than endocarditis, there has been increasing interest and an increasing number of reports of excellent results of valve repair in acute infective endocarditis. The theoretically ideal material for valve repair in this setting is non-permanent, “vanishing” material, not at risk of seeding or colonization. The goal of this contribution is to review currently available data on biodegradable materials for valve repair in infective endocarditis. Discussion Rigorous electronic and manual literature searches were conducted to identify reports of biodegradable materials for valve repair in infective endocarditis. Articles were identified in electronic database searches of Medline, Embase and the Cochrane Library, using a predetermined search strategy. 49 manuscripts were included in the review. Prosthetic materials needed for valve repair can be summarized into annuloplasty rings to remodel the mitral or tricuspid annulus, and patch materials to replace resected valvar tissue. The commercially available biodegradable annuloplasty ring has shown interesting clinical results in a single-center experience; however further data is required for validation and longer follow-up. Unmodified extra-cellular matrix patches, such as small intestinal submucosa, have had promising initial experimental and clinical results in non-infected valve repair, although in valve repair for endocarditis has been reported in only one patient, and concerns have been raised regarding their mechanical stability in an infected field. Summary These evolving biodegradable devices offer the potential for valve repair with degradable materials replaced with autologous tissue, which could further improve the results of valve repair for infective endocarditis. This is an evolving field with promising experimental or initial clinical results, however long-term outcomes are lacking and further data is necessary to validate this theoretically interesting approach to infective endocarditis. PMID:25087015

  12. [Inguinal hernia repair: results of randomized clinical trials and meta-analyses].

    PubMed

    Slim, K; Vons, C

    2008-01-01

    This evidence-based review of the literature aims to answer two questions regarding inguinal hernia repair: 1. should a prosthetic patch be used routinely? 2. Which approach is better - laparoscopic or open surgery? After a comprehensive search of electronic databases we retained only meta-analyses (n=14) and/or randomised clinical trials (n=4). Review of this literature suggests with a good level of evidence that prosthetic hernia repair is the gold standard; the laparoscopic approach has very few proven benefits and may involve more serious complications when performed outside expert centers. The role of laparoscopy for the repair of bilateral or recurrent hernias needs better evaluation.

  13. Development of Guidelines for In-Situ Repair of SLS-Class Composite Flight Hardware

    NASA Technical Reports Server (NTRS)

    Weber, Thomas P., Jr.; Cox, Sarah B.

    2018-01-01

    The purpose of composite repair development at KSC (John F. Kennedy Space Center) is to provide support to the CTE (Composite Technology for Exploration) project. This is a multi-space center effort with the goal of developing bonded joint technology for SLS (Space Launch System) -scale composite hardware. At KSC, effective and efficient repair processes need to be developed to allow for any potential damage to composite components during transport or launch preparation. The focus of the composite repair development internship during the spring of 2018 was on the documentation of repair processes and requirements for process controls based on techniques developed through hands-on work with composite test panels. Three composite test panels were fabricated for the purpose of repair and surface preparation testing. The first panel included a bonded doubler and was fabricated to be damaged and repaired. The second and third panels were both fabricated to be cut into lap-shear samples to test the strength of bond of different surface preparation techniques. Additionally, jointed composite test panels were impacted at MSFC (Marshall Space Flight Center) and analyzed for damage patterns. The observations after the impact tests guided the repair procedure at KSC to focus on three repair methods. With a finalized repair plan in place, future work will include the strength testing of different surface preparation techniques, demonstration of repair methods, and repair of jointed composite test panels being impacted at MSFC.

  14. INTERNAL REPAIR OF PIPELINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robin Gordon; Bill Bruce; Nancy Porter

    2003-05-01

    The two broad categories of deposited weld metal repair and fiber-reinforced composite repair technologies were reviewed for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Preliminary test programs were developed for both deposited weld metal repairs and for fiber-reinforced composite repair. To date, all of the experimental work pertaining to the evaluation of potential repair methods has focused on fiber-reinforced composite repairs. Hydrostatic testing was also conducted on four pipeline sections with simulated corrosion damage: twomore » with composite liners and two without.« less

  15. Light-Curing Adhesive Repair Tapes

    NASA Technical Reports Server (NTRS)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.

  16. Earlier Pulmonary Valve Replacement in Down Syndrome Patients Following Tetralogy of Fallot Repair.

    PubMed

    Sullivan, Rachel T; Frommelt, Peter C; Hill, Garick D

    2017-08-01

    The association between Down syndrome and pulmonary hypertension could contribute to more severe pulmonary regurgitation after tetralogy of Fallot repair and possibly earlier pulmonary valve replacement. We compared cardiac magnetic resonance measures of pulmonary regurgitation and right ventricular dilation as well as timing of pulmonary valve replacement between those with and without Down syndrome after tetralogy of Fallot repair. Review of our surgical database from 2000 to 2015 identified patients with tetralogy of Fallot with pulmonary stenosis. Those with Down syndrome were compared to those without. The primary outcome of interest was time from repair to pulmonary valve replacement. Secondary outcomes included pulmonary regurgitation and indexed right ventricular volume on cardiac magnetic resonance imaging. The cohort of 284 patients included 35 (12%) with Down syndrome. Transannular patch repair was performed in 210 (74%). Down syndrome showed greater degree of pulmonary regurgitation (55 ± 14 vs. 37 ± 16%, p = 0.01) without a significantly greater rate of right ventricular dilation (p = 0.09). In multivariable analysis, Down syndrome (HR 2.3, 95% CI 1.2-4.5, p = 0.02) and transannular patch repair (HR 5.5, 95% CI 1.7-17.6, p = 0.004) were significant risk factors for valve replacement. Those with Down syndrome had significantly lower freedom from valve replacement (p = 0.03). Down syndrome is associated with an increased degree of pulmonary regurgitation and earlier pulmonary valve replacement after tetralogy of Fallot repair. These patients require earlier assessment by cardiac magnetic resonance imaging to determine timing of pulmonary valve replacement and evaluation for and treatment of preventable causes of pulmonary hypertension.

  17. Gene manipulated peritoneal cell patch repairs infarcted myocardium

    PubMed Central

    Huang, Wei; Zhang, Dongsheng; Millard, Ronald W.; Wang, Tao; Zhao, Tiemin; Fan, Guo-Chang; Ashraf, Atif; Xu, Meifeng; Ashraf, Muhammad; Wang, Yigang

    2010-01-01

    A gene manipulated cell patch using a homologous peritoneum substrate was developed and applied after myocardial infarction to repair scarred myocardium. We genetically engineered male rat mesenchymal stem cells (MSC) using adenoviral transduction to over-express CXCR4/green fluorescent protein (GFP) (MSCCXCR4) or MSCNull or siRNA targeting CXCR4 (MSCsiRNA). Gene expression was studied by real-time quantitative PCR (qPCR) and enzyme-linked immunosorbent assay (ELISA). Cells were cultured on excised peritoneum for 9 days. Two weeks after left anterior descending (LAD) coronary artery ligation in female hearts, the peritoneum patch was applied over the scarred myocardium, cell side down. Efficacy of engraftment was determined by presence of GFP positive cells. One month after cell implantation, echocardiography was performed and hearts were harvested for histological analysis. Left ventricle (LV) fibrosis, LV anterior wall thickness (AWT) and blood vessel density at the margins of the graft were measured. There was significant up-regulation of the chemokines in the MSCCXCR4 group cultured under normoxic conditions when compared to the MSCNull group and a further increase was observed after exposure to hypoxia. One month after cell transplantation with the peritoneum patch, substantial numbers of GFP-positive cells were observed in and around the infarcted myocardium in MSCCXCR4 group. LV AWT, LV fibrosis and LV function were significantly improved in the MSCCXCR4 group as compared to these same variables in the MSCNull control. These salutary effects were absent in MSCsiRNA group. The gene manipulated MSC-seeded peritoneum patch promotes tissue nutrition (angiogenesis), reduces myocardial remodeling, and enhances heart function after myocardial infarction. PMID:19913551

  18. The Fanconi Anemia DNA Repair Pathway Is Regulated by an Interaction between Ubiquitin and the E2-like Fold Domain of FANCL*

    PubMed Central

    Miles, Jennifer A.; Frost, Mark G.; Carroll, Eilis; Rowe, Michelle L.; Howard, Mark J.; Sidhu, Ateesh; Chaugule, Viduth K.; Alpi, Arno F.; Walden, Helen

    2015-01-01

    The Fanconi Anemia (FA) DNA repair pathway is essential for the recognition and repair of DNA interstrand crosslinks (ICL). Inefficient repair of these ICL can lead to leukemia and bone marrow failure. A critical step in the pathway is the monoubiquitination of FANCD2 by the RING E3 ligase FANCL. FANCL comprises 3 domains, a RING domain that interacts with E2 conjugating enzymes, a central domain required for substrate interaction, and an N-terminal E2-like fold (ELF) domain. The ELF domain is found in all FANCL homologues, yet the function of the domain remains unknown. We report here that the ELF domain of FANCL is required to mediate a non-covalent interaction between FANCL and ubiquitin. The interaction involves the canonical Ile44 patch on ubiquitin, and a functionally conserved patch on FANCL. We show that the interaction is not necessary for the recognition of the core complex, it does not enhance the interaction between FANCL and Ube2T, and is not required for FANCD2 monoubiquitination in vitro. However, we demonstrate that the ELF domain is required to promote efficient DNA damage-induced FANCD2 monoubiquitination in vertebrate cells, suggesting an important function of ubiquitin binding by FANCL in vivo. PMID:26149689

  19. Damage Tolerant Repair Techniques for Pressurized Aircraft Fuselages

    DTIC Science & Technology

    1994-01-01

    2 if20 20 offset 50, fatigue GST, GLARE 2 if20 20 static, no fatigue *Unidirectional SP500 carbon/epoxy tape . "* Fatigue load did not initiate a crack...Et value, so this is a reasonable assumption. It further implies zero crack opening under the patch. The Erdogan solution [51 for two collinear...Cr Figure 6. 11. Idealization of patched crack as unfailed ligament between two collinear cracks (after [5, 6)). The Erdogan solution leads to the AK

  20. Two-year interfacial bond durability and nanoleakage of repaired silorane-based resin composite.

    PubMed

    Mobarak, E; El-Deeb, H

    2013-01-01

    To investigate the effect of silane primer application, intermediate adhesive agent/repair composite, and storage period on the interfacial microtensile bond strength (μTBS) of repaired silorane-based resin composite compared with unrepaired composites and on the nanoleakage. Forty-eight 1-month-old substrate specimens from Filtek P90 were roughened, etched, and distributed over two groups (n=24) based on receiving silane (Clearfil Ceramic Primer) or not. Then, half of the specimens (n=12) were repaired with P90 System Adhesive/Filtek P90 and the other half with Adper Scotchbond Multipurpose adhesive/Filtek Z250 resin composite. Within each repair category, repaired specimens were stored in artificial saliva at 37°C for either 24 hours (n=6) or two years before being serially sectioned into sticks (0.6 ± 0.01 mm(2)). From each specimen, two sticks were prepared for nanoleakage determination and four sticks were used for μTBS testing. Additional unrepaired specimens from each composite (n=12) were made to determine the cohesive strength at 24 hours and two years. Mean μTBS were calculated and statistically analyzed. Modes of failure were also determined. General linear model analysis revealed no significant effect for the silane priming, intermediate adhesive agent/repair composite, and storage period or for their interactions on the μTBS values of the repaired specimens. There was no significant difference between the cohesive strength of Filtek P90 and Filtek Z250; both were significantly higher than all repaired categories. At 24 hours, nanoleakage was not detected when silorane-based composite was repaired with the same material. However, after two years, all repair categories showed nanoleakage. Silane application has no effect on μTBS and nanoleakage. Durability of the interfacial bond of repaired silorane-based resin composite appeared successful regardless of the chemistry of the intermediate adhesive agent/composite used for repair. However, nanoleakage was detected early when a different repair intermediate adhesive agent/composite was used.

  1. Product evaluation : Thoro product demonstration

    DOT National Transportation Integrated Search

    1986-07-18

    This report contains a product evaluation of Thoro System's "Roadpatch" and "Thorite". Roadpatch is a cement base, fast-setting patching material. The material is fortified with special alkali resistant glass fibers. It is designed to repair potholes...

  2. Graft Utilization in the Augmentation of Large-to-Massive Rotator Cuff Repairs: A Systematic Review.

    PubMed

    Ferguson, Devin P; Lewington, Matthew R; Smith, T Duncan; Wong, Ivan H

    2016-11-01

    Current treatment options for symptomatic large-to-massive rotator cuff tears can reduce pain, but failure rates remain high. Surgeons have incorporated synthetic and biologic grafts to augment these repairs, with promising results. Multiple reviews exist that summarize these products; however, no systematic review has investigated the grafts' ability to maintain structural integrity after augmentation of large-to-massive rotator cuff repairs. To systematically review and evaluate the effectiveness of grafts in the augmentation of large-to-massive rotator cuff repairs. Systematic review. A comprehensive search of 4 reputable databases was completed. Inclusion criteria were (1) large-to-massive rotator cuff tear, (2) graft augmentation of primary repairs ± primary repair control group, and (3) minimum clinical and radiologic follow-up of 12 months. Two reviewers screened the titles, abstracts, and full articles and extracted the data from eligible studies. Results were summarized into evidence tables stratified by graft origin and level of evidence. Ten studies fit the inclusion criteria. Allograft augmentation was functionally and structurally superior to primary repair controls, with intact repairs in 85% versus 40% of patients (P < .01). This was supported by observational study data. Xenograft augmentation failed to demonstrate superiority to primary repair controls, with worse structural healing rates (27% vs 60%; P =.11). Both comparative studies supported this finding. There have also been many reports of inflammatory reactions with xenograft use. Polypropylene patches are associated with improved structural (83% vs 59% and 49%; P < .01) and functional outcomes when compared with controls and xenograft augmentation; however, randomized data are lacking. Augmentation of large-to-massive rotator cuff repairs with human dermal allografts is associated with superior functional and structural outcome when compared with conventional primary repair. Xenograft augmentation failed to demonstrate a statistically significant difference and may be associated with worse rerupture rates and occasional severe inflammatory reactions. Polypropylene patches have initial promising results. Research in this field is limited; future researchers should continue to develop prospective, randomized controlled trials to establish clear recommendations. © 2016 The Author(s).

  3. Fatigue behavior of a thermally-activated NiTiNb SMA-FRP patch

    NASA Astrophysics Data System (ADS)

    El-Tahan, M.; Dawood, M.

    2016-01-01

    This paper presents the details of an experimental study that was conducted to characterize the fatigue behavior of a thermally-activated shape memory alloy (SMA)/carbon fiber reinforced polymer (CFRP) patch that can be used to repair cracked steel members. A total of 14 thermally-activated patches were fabricated and tested to evaluate the stability of the prestress under fatigue loading. The parameters considered in this study are the prestress level in the nickel-titanium-niobium SMA wires and the applied force range. An empirical model to predict the degradation of the prestress is also presented. The results indicate that patches for which the maximum applied loads in a fatigue cycle did not cause debonding of the SMA wires from the CFRP sustained two million loading cycles with less than 20% degradation of the prestress.

  4. Mechanical and Vibration Testing of Carbon Fiber Composite Material with Embedded Piezoelectric Sensors

    NASA Technical Reports Server (NTRS)

    Duffy, Kirsten P.; Lerch, Bradley A.; Wilmoth, Nathan G.; Kray, Nicholas; Gemeinhardt, Gregory

    2012-01-01

    Piezoelectric materials have been proposed as a means of decreasing turbomachinery blade vibration either through a passive damping scheme, or as part of an active vibration control system. For polymer matrix fiber composite (PMFC) blades, the piezoelectric elements could be embedded within the blade material, protecting the brittle piezoceramic material from the airflow and from debris. Before implementation of a piezoelectric element within a PMFC blade, the effect on PMFC mechanical properties needs to be understood. This study attempts to determine how the inclusion of a packaged piezoelectric patch affects the material properties of the PMFC. Composite specimens with embedded piezoelectric patches were tested in four-point bending, short beam shear, and flatwise tension configurations. Results show that the embedded piezoelectric material does decrease the strength of the composite material, especially in flatwise tension, attributable to failure at the interface or within the piezoelectric element itself. In addition, the sensing properties of the post-cured embedded piezoelectric materials were tested, and performed as expected. The piezoelectric materials include a non-flexible patch incorporating solid piezoceramic material, and two flexible patch types incorporating piezoelectric fibers. The piezoceramic material used in these patches was Navy Type-II PZT.

  5. A modern era comparison of right versus left sided congenital diaphragmatic hernia outcomes.

    PubMed

    Collin, Michael; Trinder, Sarah; Minutillo, Corrado; Rao, Shripada; Dickinson, Jan; Samnakay, Naeem

    2016-09-01

    This study aims to retrospectively review outcomes, including neurodevelopmental outcomes, of neonatal right sided congenital diaphragmatic hernias (RCDH) compared with left sided congenital diaphragmatic hernias (L-CDH) treated surgically at our institute. A retrospective review was undertaken of all cases of congenital diaphragmatic hernia (CDH) treated at Princess Margaret Hospital for Children (PMH), Perth, born between 1st January 2002 and 1st August 2012. The outcomes of R-CDH cases were compared with L-CDH cases. We examined duration of ventilatory support, use of patch versus primary closure, the CDH recurrence rates, the number of reoperations and neurodevelopmental follow-up at one year of age. Forty-nine cases of CDH were operated on at PMH during the 10-year period. Of these, ten cases were R-CDH with 39 L-CDH cases. Of 49 cases, 34 were diagnosed antenatally, 5 R-CDH versus 29 L-CDH. Only 8/39 cases of L-CDH required patch repair for larger defects, while 5/10 R-CDH required patch repair. Postoperative mortality was 6/49 (1/10 right sided versus 5/39 left sided). Recurrence was observed in 5/10 R-CDH versus 6/39 L-CDH with p=0.03. Thirty-three of 43 surviving patients received one-year follow-up with Griffiths general quotient (GQ) assessment demonstrating a median score of 98 for L-CDH (IQR 86 to 104.25) and 91 for R-CDH (IQR 76.5 to 93). R-CDH required patch repair more commonly than L-CDH because of larger defect size or complete agenesis. The rate of recurrent herniation was the only morbidity significantly higher in the R-CDH group. Survivors of R-CDH did not have a significant difference in neurodevelopmental outcome compared to L-CDH cases, with both groups exhibiting normal median GQ scores at one year of age. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  6. Engineering properties of brittle repair materials : summary report.

    DOT National Transportation Integrated Search

    1992-09-01

    Most codes of practice prescribe procedures for selecting patch configuration and materials based on test devised for evaluating new pavement materials. This study is aimed at examining the special consideration to be given to such evaluation procedu...

  7. Performance analysis of smart laminated composite plate integrated with distributed AFC material undergoing geometrically nonlinear transient vibrations

    NASA Astrophysics Data System (ADS)

    Shivakumar, J.; Ashok, M. H.; Khadakbhavi, Vishwanath; Pujari, Sanjay; Nandurkar, Santosh

    2018-02-01

    The present work focuses on geometrically nonlinear transient analysis of laminated smart composite plates integrated with the patches of Active fiber composites (AFC) using Active constrained layer damping (ACLD) as the distributed actuators. The analysis has been carried out using generalised energy based finite element model. The coupled electromechanical finite element model is derived using Von Karman type nonlinear strain displacement relations and a first-order shear deformation theory (FSDT). Eight-node iso-parametric serendipity elements are used for discretization of the overall plate integrated with AFC patch material. The viscoelastic constrained layer is modelled using GHM method. The numerical results shows the improvement in the active damping characteristics of the laminated composite plates over the passive damping for suppressing the geometrically nonlinear transient vibrations of laminated composite plates with AFC as patch material.

  8. Scale-specific habitat relationships influence patch occupancy: defining neighborhoods to optimize the effectiveness of landscape-scale grassland bird conservation

    USGS Publications Warehouse

    Guttery, Michael; Ribic, Christine; Sample, David W.; Paulios, Andy; Trosen, Chris; Dadisman, John D.; Schneider, Daniel; Horton, Josephine

    2017-01-01

    ContextBeyond the recognized importance of protecting large areas of contiguous habitat, conservation efforts for many species are complicated by the fact that patch suitability may also be affected by characteristics of the landscape within which the patch is located. Currently, little is known about the spatial scales at which species respond to different aspects of the landscape surrounding an occupied patch.ObjectivesUsing grassland bird point count data, we describe an approach to evaluating scale-specific effects of landscape composition on patch occupancy.MethodsWe used data from 793 point count surveys conducted in idle and grazed grasslands across Wisconsin, USA from 2012 to 2014 to evaluate scale-dependencies in the response of grassland birds to landscape composition. Patch occupancy models were used to evaluate the relationship between occupancy and landscape composition at scales from 100 to 3000 m.ResultsBobolink (Dolichonyx oryzivorus) exhibited a pattern indicating selection for grassland habitats in the surrounding landscape at all spatial scales while selecting against other habitats. Eastern Meadowlark (Sturnella magna) displayed evidence of scale sensitivity for all habitat types. Grasshopper Sparrow (Ammodramus savannarum) showed a strong positive response to pasture and idle grass at all scales and negatively to cropland at large scales. Unlike other species, patch occupancy by Henslow’s Sparrow (A. henslowii) was primarily influenced by patch area.ConclusionsOur results suggest that both working grasslands (pasture) and idle conservation grasslands can play an important role in grassland bird conservation but also highlight the importance of considering species-specific patch and landscape characteristics for effective conservation.

  9. Acute aortic dissection involving the root: operative and long-term outcome after curative proximal repair†

    PubMed Central

    Urbanski, Paul P.; Lenos, Aristidis; Irimie, Vadim; Bougioukakis, Petros; Zacher, Michael; Diegeler, Anno

    2016-01-01

    OBJECTIVES The aim of the study was to evaluate operative and long-term results after surgery of acute aortic dissection involving the root, in which the proximal repair consisted of curative resection of all dissected aortic sinuses and was performed using either valve-sparing root repair or complete root replacement with a valve conduit. METHODS Between August 2002 and March 2013, 162 consecutive patients (mean age 63 ± 14 years) underwent surgery for acute type A aortic dissection. Eighty-six patients with an involvement of the aortic root underwent curative surgery of the proximal aorta consisting of valve-sparing root repair (n = 54, 62.8%) or complete valve and root replacement using composite valve grafts (n = 32, 37.2%). In patients with root repair, all dissected aortic walls were resected and root remodelling using the single patch technique (n = 53) or root repair with valve reimplantation (n = 1) was performed without the use of any glue. All perioperative data were collected prospectively and retrospective statistical examination was performed using univariate and multivariate analyses. RESULTS The mean follow-up was 5.2 ± 3.5 years for all patients (range 0–12 years) and 6.1 ± 3.3 years for survivors. The 30-day mortality rate was 5.8% (5 patients), being considerably lower in the repair sub-cohort (1.9 vs 12.5%). The estimated survival rate at 5 and 10 years was 80.0 ± 4.5 and 69.1 ± 6.7%, respectively. No patient required reoperation on the proximal aorta and/or aortic valve during the follow-up time and there were only two valve-related events (both embolic, one in each group). Among those patients with repaired valves, the last echocardiography available showed no insufficiency in 40 and an irrelevant insufficiency (1+) in 14. CONCLUSIONS Curative repair of the proximal aorta in acute dissection involving the root provides favourable operative and long-term outcome with very low risk of aortic complications and/or reoperations, regardless if a valve-sparing procedure or replacement with a valve conduit is used. Valve-sparing surgery is frequently suitable, providing excellent outcome and very high durability. PMID:26848190

  10. Spatiotemporal modeling of laser tissue soldering using photothermal nanocomposites.

    PubMed

    Mushaben, Madaline; Urie, Russell; Flake, Tanner; Jaffe, Michael; Rege, Kaushal; Heys, Jeffrey

    2018-02-01

    Laser tissue soldering using photothermal solders is a technology that facilitates rapid sealing using heat-induced changes in the tissue and the solder material. The solder material is made of gold nanorods embedded in a protein matrix patch that can be placed over the tissue rupture site and heated with a laser. Although laser tissue soldering is an attractive approach for surgical repair, potential photothermal damage can limit the success of this approach. Development of predictive mathematical models of photothermal effects including cell death, can lead to more efficient approaches in laser-based tissue repair. We describe an experimental and modeling investigation into photothermal solder patches for sealing porcine and mouse cadaver intestine sections using near-infrared laser irradiation. Spatiotemporal changes in temperature were determined at the surface as well as various depths below the patch. A mathematical model, based on the finite element method, predicts the spatiotemporal temperature distribution in the patch and surrounding tissue, as well as concomitant cell death in the tissue is described. For both the porcine and mouse intestine systems, the model predicts temperatures that are quantitatively similar to the experimental measurements with the model predictions of temperature increase often being within a just a few degrees of experimental measurements. This mathematical model can be employed to identify optimal conditions for minimizing healthy cell death while still achieving a strong seal of the ruptured tissue using laser soldering. Lasers Surg. Med. 50:143-152, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  11. Investigation on Flexure Test of Composite Beam of Repair Materials and Substrate Concrete for Durable Repair

    NASA Astrophysics Data System (ADS)

    Pattnaik, Rashmi R.; Rangaraju, Prasada Rao

    2014-12-01

    An experimental study was conducted on composite beam of repair materials and substrate concrete to investigate the failures of concrete repair due to differences in strength of repair materials and substrate concrete. In this investigation the flexural strength, load-deflection curves and failure patterns of the composite beam specimens are studied for the durability of the concrete repair. Flexure test was conducted to simulate tensile stress in the concrete repair material. Compressive strength and split tensile strength of the repair materials and substrate concrete are investigated to aid in the analysis of the concrete repair. It was observed that the repair materials of higher compressive strength than the substrate concrete are causing an incompatible failure in the concrete repair.

  12. Shear horizontal guided wave modes to infer the shear stiffness of adhesive bond layers.

    PubMed

    Le Crom, Bénédicte; Castaings, Michel

    2010-04-01

    This paper presents a non-destructive, ultrasonic technique to evaluate the quality of bonds between substrates. Shear-horizontally polarized (SH) wave modes are investigated to infer the shear stiffness of bonds, which is necessarily linked to the shear resistance that is a critical parameter for bonded structures. Numerical simulations are run for selecting the most appropriate SH wave modes, i.e., with higher sensitivity to the bond than to other components, and experiments are made for generating-detecting pre-selected SH wave modes and for measuring their phase velocities. An inverse problem is finally solved, consisting of the evaluation of the shear stiffness modulus of a bond layer at different curing times between a metallic plate and a composite patch, such assembly being investigated in the context of repair of aeronautical structures.

  13. Plating Patches On Heat-Exchanger Jackets

    NASA Technical Reports Server (NTRS)

    Loureiro, Henry; Kubik, Frank

    1989-01-01

    Permanent repairs made without welding. Technique used to repair nickel-alloy nozzle jacket of Space Shuttle main engine. Applicable to other metal heat-exchanger jackets with similar configurations. Does not require welding, brazing, soldering, or other operations involving high temperatures and consequent damage to surrounding areas. Portion of jacket around damaged area removed by grinding and polishing out to edges adjacent to tube/jacket braze bonds. Spaces between tubes filled with wax preventing contamination of spaces during subsequent plating.

  14. The Fanconi Anemia DNA Repair Pathway Is Regulated by an Interaction between Ubiquitin and the E2-like Fold Domain of FANCL.

    PubMed

    Miles, Jennifer A; Frost, Mark G; Carroll, Eilis; Rowe, Michelle L; Howard, Mark J; Sidhu, Ateesh; Chaugule, Viduth K; Alpi, Arno F; Walden, Helen

    2015-08-21

    The Fanconi Anemia (FA) DNA repair pathway is essential for the recognition and repair of DNA interstrand crosslinks (ICL). Inefficient repair of these ICL can lead to leukemia and bone marrow failure. A critical step in the pathway is the monoubiquitination of FANCD2 by the RING E3 ligase FANCL. FANCL comprises 3 domains, a RING domain that interacts with E2 conjugating enzymes, a central domain required for substrate interaction, and an N-terminal E2-like fold (ELF) domain. The ELF domain is found in all FANCL homologues, yet the function of the domain remains unknown. We report here that the ELF domain of FANCL is required to mediate a non-covalent interaction between FANCL and ubiquitin. The interaction involves the canonical Ile44 patch on ubiquitin, and a functionally conserved patch on FANCL. We show that the interaction is not necessary for the recognition of the core complex, it does not enhance the interaction between FANCL and Ube2T, and is not required for FANCD2 monoubiquitination in vitro. However, we demonstrate that the ELF domain is required to promote efficient DNA damage-induced FANCD2 monoubiquitination in vertebrate cells, suggesting an important function of ubiquitin binding by FANCL in vivo. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  15. Endoscopic observation of different repair patterns in human traumatic tympanic membrane perforations.

    PubMed

    Huang, Peng; Zhang, Shujun; Gong, Xinhong; Wang, Xuesong; Lou, Zi-Han

    2017-08-03

    In the last decade, there has been an increasing use of biomaterial patches in the regeneration of traumatic tympanic membrane perforations. The major advantages of biomaterial patches are to provisionally restore the physiological function of the middle ear, thereby immediately improving ear symptoms, and act as a scaffold for epithelium migration. However, whether there are additional biological effects on eardrum regeneration is unclear for biological material patching in the clinic. This study evaluated the healing response for different repair patterns in human traumatic tympanic membrane perforations by endoscopic observation. In total, 114 patients with traumatic tympanic membrane perforations were allocated sequentially to two groups: the spontaneous healing group (n=57) and Gelfoam patch-treated group (n=57). The closure rate, closure time, and rate of otorrhea were compared between the groups at 3 months. Ultimately, 107 patients were analyzed in the two groups (52 patients in the spontaneous healing group vs. 55 patients in the Gelfoam patch-treated group). The overall closure rate at the end of the 3 month follow-up period was 90.4% in the spontaneous healing group and 94.5% in the Gelfoam patch-treated group; the difference was not statistically significant (p>0.05). However, the total average closure time was significantly different between the two groups (26.8±9.1 days in the spontaneous healing group vs. 14.7±9.1 days in the Gelfoam patch-treated group, p<0.01). In addition, the closure rate was not significantly different between the spontaneous healing group and Gelfoam patch-treated group regardless of the perforation size. The closure time in the Gelfoam patch-treated group was significantly shorter than that in the spontaneous healing group regardless of the perforation size (small perforations: 7.1±1.6 days vs. 12.6±3.9, medium-sized perforations: 13.3±2.2 days vs. 21.8±4.2 days, and large perforations: 21.2±4.7 days vs. 38.4±5.7 days; p<0.01). In the regeneration of traumatic tympanic membrane perforations, Gelfoam patching not only plays a scaffolding role for epithelial migration, it also promotes edema and hyperplasia of granulation tissue at the edges of the perforation and accelerates eardrum healing. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  16. Oral buccal mucous membrane allograft with a corneal lamellar graft for the repair of Boston type 1 keratoprosthesis stromal melts.

    PubMed

    Ziai, Setareh; Rootman, David S; Slomovic, Allan R; Chan, Clara C

    2013-11-01

    To describe a surgical technique to repair Boston type 1 keratoprosthesis (KPro)-related corneal melts. Technique description and review of 3 representative cases. After harvesting the buccal mucosa from the patient's inner lower lip, the exposed area of the KPro back plate is prepared for repair by adequate exposure and removal of necrotic tissue. The area is then covered with a lamellar patch of cornea secured in place with interrupted 10-0 nylon sutures, followed by a thin layer of buccal mucosa secured in place with interrupted 8-0 vicryl sutures. This technique provides surgeons with a method to repair KPro-related corneal melts when there is a conjunctival deficiency.

  17. Engineering properties of brittle repair materials : final report : volume I.

    DOT National Transportation Integrated Search

    1992-09-01

    Most codes of practice prescribe procedures for selecting patch configuration and materials based on tests devised for evaluating new pavement materials. This study is aimed at examining the special consideration to be given to such evaluation proced...

  18. Engineering properties of brittle repair materials : final report : volume II.

    DOT National Transportation Integrated Search

    1992-09-01

    Most codes of practice prescribe procedures for selecting patch configuration and materials based on tests devised for evaluating new pavement materials. This study is aimed at examining the special consideration to be given to such evaluation proced...

  19. Dye-enhanced protein solders and patches in laser-assisted tissue welding.

    PubMed

    Small, W; Heredia, N J; Maitland, D J; Da Silva, L B; Matthews, D L

    1997-01-01

    This study examines the use of dye-enhanced protein bonding agents in 805 nm diode laser-assisted tissue welding. A comparison of an albumin liquid solder and collagen solid-matrix patches used to repair arteriotomies in an in vitro porcine model is presented. Extrinsic bonding media in the form of solders and patches have been used to enhance the practice of laser tissue welding. Preferential absorption of the laser wavelength has been achieved by the incorporation of chromophores. Both the solder and the patch included indocyanine green dye (ICG) to absorb the 805 nm continuous-wave diode laser light used to perform the welds. Solder-mediated welds were divided into two groups (high power/short exposure and low power/long exposure), and the patches were divided into three thickness groups ranging from 0.1 to 1.3 mm. The power used to activate the patches was constant, but the exposure time was increased with patch thickness. Burst pressure results indicated that solder-mediated and patched welds yielded similar average burst strengths in most cases, but the patches provided a higher success rate (i.e., more often exceeded 150 mmHg) and were more consistent (i.e., smaller standard deviation) than the solder. The strongest welds were obtained using 1.0-1.3 mm thick patches, while the high power/short exposure solder group was the weakest. Though the solder and patches yielded similar acute weld strengths, the solid-matrix patches facilitated the welding process and provided consistently strong welds. The material properties of the extrinsic agents influenced their performance.

  20. Testing of self-repairing composite airplane components by use of CAI and the release of the repair chemicals from carefully inserted small tubes

    NASA Astrophysics Data System (ADS)

    Dry, Carolyn

    2007-04-01

    The research on self repair of airplane components, under an SBIR phase II with Wright Patterson Air Force Base, has investigated the attributes and best end use applications for such a technology. These attributes include issues related to manufacturability, cost, potential benefits such as weight reduction, and cost reduction. The goal of our research has been to develop self-repairing composites with unique strength for air vehicles. Our revolutionary approach involves the autonomous release of repair chemicals from within the composite matrix itself. The repair agents are contained in hollow, structural fibers that are embedded within the matrix. Under stress, the composite senses external environmental factors and reacts by releasing the repair agents from within the hollow vessels. This autonomous response occurs wherever and whenever cracking, debonding or other matrix damage transpires. Superior performance over the life of the composite is achieved through this self-repairing mechanism. The advantages to the military would be safely executed missions, fewer repairs and eventually lighter vehicles. In particular the research has addressed the issues by correlating the impact of the various factors, such as 1) delivery vessel placement, shape/size and effect on composite strength, chemicals released and their effect on the matrix, release trigger and efficacy and any impact on matrix properties 2) impact of composite processing methods that involve heat and pressure on the repair vessels. Our self repairing system can be processed at temperatures of 300-350F, repairs in less than 30 seconds and does not damage the composite by repair fiber insertion or chemical release. Scaling up and manufacture of components has revealed that anticipating potential problems allowed us to avoid those associated with processing temperatures and pressures. The presentation will focus on compression after impact testing and the placement of repair fibers/tubes into prepreg laminates.

  1. Flexible shape-memory scaffold for minimally invasive delivery of functional tissues

    NASA Astrophysics Data System (ADS)

    Montgomery, Miles; Ahadian, Samad; Davenport Huyer, Locke; Lo Rito, Mauro; Civitarese, Robert A.; Vanderlaan, Rachel D.; Wu, Jun; Reis, Lewis A.; Momen, Abdul; Akbari, Saeed; Pahnke, Aric; Li, Ren-Ke; Caldarone, Christopher A.; Radisic, Milica

    2017-10-01

    Despite great progress in engineering functional tissues for organ repair, including the heart, an invasive surgical approach is still required for their implantation. Here, we designed an elastic and microfabricated scaffold using a biodegradable polymer (poly(octamethylene maleate (anhydride) citrate)) for functional tissue delivery via injection. The scaffold’s shape memory was due to the microfabricated lattice design. Scaffolds and cardiac patches (1 cm × 1 cm) were delivered through an orifice as small as 1 mm, recovering their initial shape following injection without affecting cardiomyocyte viability and function. In a subcutaneous syngeneic rat model, injection of cardiac patches was equivalent to open surgery when comparing vascularization, macrophage recruitment and cell survival. The patches significantly improved cardiac function following myocardial infarction in a rat, compared with the untreated controls. Successful minimally invasive delivery of human cell-derived patches to the epicardium, aorta and liver in a large-animal (porcine) model was achieved.

  2. Repair of Inaccessible Ventral Dural Defect in Thoracic Spine: Double Layered Duraplasty

    PubMed Central

    Lee, Dong-Hyun; Park, Jeong-Ill; Park, Ki-Su; Cho, Dae-Chul; Sung, Joo-Kyung

    2016-01-01

    We propose a double layered (intradural and epidural patch) duraplasty that utilizes Lyoplant and Duraseal. We examined a 47-year-old woman after decompression for thoracic ossification of posterior longitudinal ligament was performed in another hospital. On postoperative day 7, she complained of weakness in both legs. Postoperative magnetic resonance imaging (MRI) showed cerebrospinal fluid (CSF) collection with cord compression. In the operative field, we found 2 large dural defects on the ventral dura mater. We performed a conventional fat graft with fibrin glue. However, the patient exhibited neurologic deterioration, and a postoperative MRI again showed CSF collection. We performed dorsal midline durotomy and inserted a intradural and epidural Lyoplant patch. She immediately experienced diminishing back pain postoperatively. Her visual analog scale and motor power improved markedly. Postoperative MRIs performed at 2 and 16 months showed no spinal cord compression or CSF leakage to the epidural space. We describe a new technique for double layered duraplasty. Although we do not recommend this technique for all dural repairs, double-layered duraplasty may be useful for repairing large inaccessible dural tears in cases of persistent CSF leakage refractory to conventional management. PMID:27437022

  3. Acrylate-induced allergic contact dermatitis in a car windscreen repairer.

    PubMed

    Fremlin, G; Sansom, J

    2014-10-01

    We report a case of an allergic skin reaction to ultraviolet-cured acrylates in a windscreen repair worker. The patient presented with a 6 month history of fingertip dryness, vesicles and desquamation. He had worked as a self-employed car windscreen repairer for 19 years. Previous management with vinyl glove protection and treatment with clobetasol propionate ointment had produced little improvement. He was patch tested to the British Society for Cutaneous Allergy standard and preservatives series and to the two acrylates used in his work environment, identified using safety data sheets, methyl methacrylate 2% pet and 2-hydroxyethylmethacrylate (2-HEMA) 2% pet. A positive reaction was seen at Day 4 to 2-HEMA, but all other patch tests were negative. An occupational allergic contact dermatitis to 2-HEMA was diagnosed. The patient was given avoidance advice and advised to use nitrile gloves. Although he was unable to give up his current work, he has continued his job using nitrile gloves with marked improvement. © The Author 2014. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. A PC-PU nanoparticle/PU/decellularized scaffold composite vascular patch: Synergistically optimized overall performance promotes endothelialization.

    PubMed

    Zhang, Jun; Liu, Cheng; Feng, Fuling; Wang, Dawei; Lu, Shuaishuai; Wei, Guo; Mo, Hong; Qiao, Tong

    2017-12-01

    Composite vascular patches have gained increasingly attention due to the limited availability of autologous patches (vascular graft materials made from the blood vessels of the same recipient), the lack of growth capability of nonautologous patches (vascular graft materials made from the blood vessels of a different donor) and the disadvantages of synthetic patches. In this study, we report a highly biocompatible phosphatidylcholine-polyurethane nanoparticle/polyurethane/decellularized scaffold composite vascular patch (PCVP). It was fabricated by a facile method - cosedimentation. Its in vitro blood and cell compatibility including hemolysis, plasma recalcification time, coagulation time, platelet adhesion and cytotoxicity was evaluated. The surface modified with phosphatidylcholine-polyurethane (PC-PU) nanoparticles exhibited the improved anticoagulation activity. The in vivo performance of the PCVP was investigated in a mouse model. The nanopatterned surface that resembled the concave-convex structure of the luminal surface of native blood vessels enhanced cell attachment, proliferation, migration and differentiation. The decellularized scaffold had the mechanical property similar to that of the targeted blood vessels, which could withstand in vivo dynamic blood pressure. The overall performance of the PCVP was synergistically optimized by each layer of the multilayer design. The patched artery remained patent and the formation of endothelial tissue - endothelialization was achieved 30days after the in vivo implantation in a mouse model. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Self-repair of cracks in brittle material systems

    NASA Astrophysics Data System (ADS)

    Dry, Carolyn M.

    2016-04-01

    One of the most effective uses for self repair is in material systems that crack because the cracks can allow the repair chemical to flow into the crack damage sites in all three dimensions. In order for the repair chemical to stay in the damage site and flow along to all the crack and repair there must be enough chemical to fill the entire crack. The repair chemical must be designed appropriately for the particular crack size and total volume of cracks. In each of the three examples of self repair in crackable brittle systems, the viscosity and chemical makeup and volume of the repair chemicals used is different for each system. Further the chemical delivery system has to be designed for each application also. Test results from self repair of three brittle systems are discussed. In "Self Repair of Concrete Bridges and Infrastructure" two chemicals were used due to different placements in bridges to repair different types of cracks- surface shrinkage and shear cracks, In "Airplane Wings and Fuselage, in Graphite" the composite has very different properties than the concrete bridges. In the graphite for airplane components the chemical also had to survive the high processing temperatures. In this composite the cracks were so definite and deep and thin that the repair chemical could flow easily and repair in all layers of the composite. In "Ceramic/Composite Demonstrating Self Repair" the self repair system not only repaired the broken ceramic but also rebounded the composite to the ceramic layer

  6. Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases

    PubMed Central

    Kuwelker, Saatchi Mahesh; Shetty, Devi Prasad; Dalvi, Bharat

    2017-01-01

    Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with severe tricuspid regurgitation (TR) 6 weeks and 3 months following the device closure. They underwent surgical repair with patch augmentation of the TV leaflets. Postoperatively, both are asymptomatic with a mild residual TR. PMID:28163430

  7. Structure and specificity of FEN-1 from Methanopyrus kandleri

    DOE PAGES

    Shah, Santosh; Dunten, Pete; Stiteler, Amanda; ...

    2014-11-18

    DNA repair is fundamental to genome stability and is found in all three domains of life. However, many archaeal species, such as Methanopyrus kandleri, contain only a subset of the eukaryotic nucleotide excision repair (NER) homologues, and those present often contain significant differences compared to their eukaryotic homologues. To clarify the role of the NER XPG-like protein Mk0566 from M. kandleri, its biochemical activity and three dimensional structure were investigated. Ultimately, we found both to be more similar to human FEN-1 than human XPG, suggesting a biological role in replication and long-patch base excision repair rather than in NER.

  8. Allergic contact dermatitis from a nonbisphenol A epoxy in a graphite fiber reinforced epoxy laminate.

    PubMed

    Mathias, C G

    1987-09-01

    An employee of the Composites Division of an aircraft engine manufacturing firm developed dermatitis associated with the handling of a graphite fiber reinforced epoxy laminate (epoxy prepreg). Patch test investigation demonstrated that the responsible causal agent was the nonbisphenol A epoxy binder, 4-glycidyloxy-N, N-diglycidylaniline. A patch test with bisphenol A epoxy from a standard patch test screening series was negative. Subsequent interviews with employees of the Composites Division suggested that a relative lack of awareness of the cutaneous hazards of fiber reinforced epoxy laminates, compared with liquid epoxy resin systems, may be an important risk factor for allergic sensitization to these composite materials.

  9. Use of a platelet-rich fibrin membrane to repair traumatic tympanic membrane perforations: a comparative study.

    PubMed

    Gür, Özer Erdem; Ensari, Nuray; Öztürk, Mehmet Türker; Boztepe, Osman Fatih; Gün, Taylan; Selçuk, Ömer Tarık; Renda, Levent

    2016-10-01

    (1) To evaluate the effects of a platelet-rich fibrin (PRF) membrane in the repair of traumatic tympanic membrane (TM) perforations; and (2) to compare the use of a PRF membrane with the paper patch technique with regard to recovery rates, healing time, and correction of the mean air-bone gap. A randomized, prospective analysis was performed for 60 patients who were treated for traumatic TM perforations using one of the two methods. Closure rate, speed of healing, and hearing gain were compared between the PRF (Group 1) and paper patch (Group 2) groups. Closure was obtained in 28 (93%) perforations in Group 1 and 25 (83%) perforations in Group 2 (p > 0.05). On day 10, full closure of the TM was observed in 24 (80%) patients in Group 1 and 16 (53%) patients in Group 2 (p < 0.05). The improvement in the mean air-bone gap was 14.1 dB in Group 1 and 12.4 dB in Group 2 on post-operative day 45 (p < 0.05). In comparison with the paper patch method, PRF, a new method, provided more rapid healing with more successful audiological results, and with no requirement for a second procedure.

  10. Novel Repair Concept for Composite Materials by Repetitive Geometrical Interlock Elements

    PubMed Central

    Hufenbach, Werner; Adam, Frank; Heber, Thomas; Weckend, Nico; Bach, Friedrich-Wilhelm; Hassel, Thomas; Zaremba, David

    2011-01-01

    Material adapted repair technologies for fiber-reinforced polymers with thermosetting matrix systems are currently characterized by requiring major efforts for repair preparation and accomplishment in all industrial areas of application. In order to allow for a uniform distribution of material and geometrical parameters over the repair zone, a novel composite interlock repair concept is introduced, which is based on a repair zone with undercuts prepared by water-jet technology. The presented numerical and experimental sensitivity analyses make a contribution to the systematic development of the interlock repair technology with respect to material and geometrical factors of influence. The results show the ability of the novel concept for a reproducible and automatable composite repair. PMID:28824134

  11. Investigation on Failures of Composite Beam and Substrate Concrete due to Drying Shrinkage Property of Repair Materials

    NASA Astrophysics Data System (ADS)

    Pattnaik, Rashmi Ranjan

    2017-06-01

    A Finite Element Analysis (FEA) and an experimental study was conducted on composite beam of repair material and substrate concrete to investigate the failures of the composite beam due to drying shrinkage property of the repair materials. In FEA, the stress distribution in the composite beam due to two concentrate load and shrinkage of repair materials were investigated in addition to the deflected shape of the composite beam. The stress distributions and load deflection shapes of the finite element model were investigated to aid in analysis of the experimental findings. In the experimental findings, the mechanical properties such as compressive strength, split tensile strength, flexural strength, and load-deflection curves were studied in addition to slant shear bond strength, drying shrinkage and failure patterns of the composite beam specimens. Flexure test was conducted to simulate tensile stress at the interface between the repair material and substrate concrete. The results of FEA were used to analyze the experimental results. It was observed that the repair materials with low drying shrinkage are showing compatible failure in the flexure test of the composite beam and deform adequately in the load deflection curves. Also, the flexural strength of the composite beam with low drying shrinkage repair materials showed higher flexural strength as compared to the composite beams with higher drying shrinkage value of the repair materials even though the strength of those materials were more.

  12. Sealing Materials for Use in Vacuum at High Temperatures

    NASA Technical Reports Server (NTRS)

    Pettit, Donald R.; Camarda, Charles J.; Lee Vaughn, Wallace

    2012-01-01

    Sealing materials that can be applied and left in place in vacuum over a wide range of temperatures (especially temperatures of a few thousand degrees Celsius) have been conceived and investigated for potential utility in repairing thermal-protection tiles on the space shuttles in orbit before returning to Earth. These materials are also adaptable to numerous terrestrial applications that involve vacuum processing and/or repair of structures that must withstand high temperatures. These materials can be formulated to have mechanical handling characteristics ranging from almost freely flowing liquid-like consistency through paste-like consistency to stiff puttylike consistency, and to retain these characteristics in vacuum until heated to high curing temperatures. A sealing material of this type can be formulated to be used in any of several different ways for example, to be impregnated into a high-temperature-fabric patch, impregnated into a high-temperature-fabric gasket for sealing a patch, applied under a patch, or applied alone in the manner of putty or wallboard compound. The sealing material must be formulated to be compatible with, and adhere to, the structural material(s) to be repaired. In general, the material consists of a vacuum-compatible liquid containing one or more dissolved compound(s) and/or mixed with suspended solid particles. Depending on the intended application, the liquid can be chosen to be of a compound that can remain in place in vacuum for a time long enough to be useful, and/or to evaporate or decompose in a controlled way to leave a useful solid residue behind. The evaporation rate is determined by proper choice of vapor pressure, application of heat, and/or application of ultraviolet light or other optical radiation. The liquid chosen for the original space shuttle application is a commercial silicone vacuum-pump oil.

  13. Optimal Location of Piezoelectric Patch on Composite Structure using Viewing Method

    NASA Astrophysics Data System (ADS)

    Samyal, Rahul; Bagha, Ashok K.

    2017-08-01

    A useful material which is manufactured by mixing of two or three different materials in homogeneous level is termed as composite material. In now day’s composite materials are used in wide area such as aerospace, automobiles, satellite, bullet proof jackets, rotor blades etc. In this paper modal analysis of composite material, mixture of polyester as matrix and glass as fiber, is carried out by using ABAQUS software. The modal analysis of composite material for fiber orientation 450 is carried out. In this paper by viewing the different mode shapes of the composite material, the optimal location of piezoelectric patch is carried out.

  14. Assessment of Pulmonary Artery Stiffness of Repaired Congenital Heart Disease Patients

    NASA Astrophysics Data System (ADS)

    Lee, Namheon; Banerjee, Rajit; Taylor, Michael; Hor, Kan

    2012-10-01

    Surgical correction or palliation of congenital heart disease (CHD) often requires augmenting the main pulmonary artery (MPA) with non-native material or placing a cylindrical graft. The degree to which this intervention affects PA compliance is largely unknown. In this study, the MPA stiffness characteristics were assessed by its compliance, distensibility, and pressure-strain modulus. Coregistered velocity encoded phase-contrast MRI and cardiac catheterization data were available for a cohort of repaired CHD patients (n=8) and controls (n=3). All patients were repaired with either an RV-PA conduit or a RV outflow tract patch. We measured the MPA area change by MRI and MPA pressure during the cath. The measurements were taken through or just distal to the conduit. The MPA compliance and distensibility for the patients were significantly lower than the controls: compliance (9.8±10.8 vs 28.3±7.7mm^2/mmHg, p<0.05), distensibility (2.2±1.5 vs 6.6±2.1%Area change/mmHg, p=0.05). The patients had a significantly higher pressure-strain modulus (152.3±116.4mmHg, p<0.05) than the controls (35.8±10.6mmHg). The abnormally elevated PA stiffness due to the rigidity of the conduit or patch material may cause a compliance mismatch resulting in high stress levels contributing to the observed progressive PA dilatation. This may be a factor in the progressive RV dilatation seen in this cohort of repaired CHD patients.

  15. Repair Options for Airframes

    DTIC Science & Technology

    2001-03-01

    typical applications. This patch configuration can be best obtained with unidirectional tape . Woven material has greater formability and could also...1979. 15. Erdogan F and Arn K, "A Sandwich Plate With a Part-Through and a Debonding Crack," Engineering Fracture Mechanics, Vol. 4, June 1972. 16

  16. Complex interaction of dendritic connectivity and hierarchical patch size on biodiversity in river-like landscapes.

    PubMed

    Carrara, Francesco; Rinaldo, Andrea; Giometto, Andrea; Altermatt, Florian

    2014-01-01

    Habitat fragmentation and land use changes are causing major biodiversity losses. Connectivity of the landscape or environmental conditions alone can shape biodiversity patterns. In nature, however, local habitat characteristics are often intrinsically linked to a specific connectivity. Such a link is evident in riverine ecosystems, where hierarchical dendritic structures command related scaling on habitat capacity. We experimentally disentangled the effect of local habitat capacity (i.e., the patch size) and dendritic connectivity on biodiversity in aquatic microcosm metacommunities by suitably arranging patch sizes within river-like networks. Overall, more connected communities that occupy a central position in the network exhibited higher species richness, irrespective of patch size arrangement. High regional evenness in community composition was found only in landscapes preserving geomorphological scaling properties of patch sizes. In these landscapes, some of the rarer species sustained regionally more abundant populations better tracking their own niche requirements compared to landscapes with homogeneous patch size or landscapes with spatially uncorrelated patch size. Our analysis suggests that altering the natural link between dendritic connectivity and patch size strongly affects community composition and population persistence at multiple scales. The experimental results are demonstrating a principle that can be tested in theoretical metacommunity models and eventually be projected to real riverine ecosystems.

  17. Angle-ply biomaterial scaffold for annulus fibrosus repair replicates native tissue mechanical properties, restores spinal kinematics, and supports cell viability.

    PubMed

    Borem, Ryan; Madeline, Allison; Walters, Joshua; Mayo, Henry; Gill, Sanjitpal; Mercuri, Jeremy

    2017-08-01

    Annulus fibrosus (AF) damage commonly occurs due to intervertebral disc (IVD) degeneration/herniation. The dynamic mechanical role of the AF is essential for proper IVD function and thus it is imperative that biomaterials developed to repair the AF withstand the mechanical rigors of the native tissue. Furthermore, these biomaterials must resist accelerated degradation within the proteolytic environment of degenerate IVDs while supporting integration with host tissue. We have previously reported a novel approach for developing collagen-based, multi-laminate AF repair patches (AFRPs) that mimic the angle-ply architecture and basic tensile properties of the human AF. Herein, we further evaluate AFRPs for their: tensile fatigue and impact burst strength, IVD attachment strength, and contribution to functional spinal unit (FSU) kinematics following IVD repair. Additionally, AFRP resistance to collagenase degradation and cytocompatibility were assessed following chemical crosslinking. In summary, AFRPs demonstrated enhanced durability at high applied stress amplitudes compared to human AF and withstood radially-directed biaxial stresses commonly borne by the native tissue prior to failure/detachment from IVDs. Moreover, FSUs repaired with AFRPs and nucleus pulposus (NP) surrogates had their axial kinematic parameters restored to intact levels. Finally, carbodiimide crosslinked AFRPs resisted accelerated collagenase digestion without detrimentally effecting AFRP tensile properties or cytocompatibility. Taken together, AFRPs demonstrate the mechanical robustness and enzymatic stability required for implantation into the damaged/degenerate IVD while supporting AF cell infiltration and viability. The quality of life for millions of individuals globally is detrimentally impacted by IVD degeneration and herniation. These pathologies often result in the structural demise of IVD tissue, particularly the annulus fibrosus (AF). Biomaterials developed for AF repair have yet to demonstrate the mechanical strength and durability required for utilization in the spine. Herein, we demonstrate the development of an angle-ply AF repair patch (AFRP) that can resist the application of physiologically relevant stresses without failure and which contributes to the restoration of functional spinal unit axial kinematics following repair. Furthermore, we show that this biomaterial can resist accelerated degradation in a simulated degenerate environment and supports AF cell viability. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  18. Valve-sparing options in tetralogy of Fallot surgery.

    PubMed

    Bacha, Emile

    2012-01-01

    Given late outcomes of patients with tetralogy of Fallot repaired in the 1970s and 1980s, as well as a better understanding of the late deleterious effects of pulmonary regurgitation, there is a tendency toward preservation of the pulmonary valve function during primary repair of tetralogy of Fallot. The bar keeps moving downward, to include smaller and more dysmorphic pulmonary valves. This article reviews some useful indications and techniques for valve-sparing options, including intraoperative balloon dilation and cusp reconstruction using a patch. Just like other valve repair techniques, no one technique can be applied uniformly, and surgeons must master a wide armamentarium of techniques. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Foliar fungal communities strongly differ between habitat patches in a landscape mosaic

    PubMed Central

    Robin, Cécile; Capdevielle, Xavier; Delière, Laurent; Vacher, Corinne

    2016-01-01

    Background Dispersal events between habitat patches in a landscape mosaic can structure ecological communities and influence the functioning of agrosystems. Here we investigated whether short-distance dispersal events between vineyard and forest patches shape foliar fungal communities. We hypothesized that these communities homogenize between habitats over the course of the growing season, particularly along habitat edges, because of aerial dispersal of spores. Methods We monitored the richness and composition of foliar and airborne fungal communities over the season, along transects perpendicular to edges between vineyard and forest patches, using Illumina sequencing of the Internal Transcribed Spacer 2 (ITS2) region. Results In contrast to our expectation, foliar fungal communities in vineyards and forest patches increasingly differentiate over the growing season, even along habitat edges. Moreover, the richness of foliar fungal communities in grapevine drastically decreased over the growing season, in contrast to that of forest trees. The composition of airborne communities did not differ between habitats. The composition of oak foliar fungal communities change between forest edge and centre. Discussion These results suggest that dispersal events between habitat patches are not major drivers of foliar fungal communities at the landscape scale. Selective pressures exerted in each habitat by the host plant, the microclimate and the agricultural practices play a greater role, and might account for the differentiation of foliar fugal communities between habitats. PMID:27833817

  20. Effect of Various Laser Surface Treatments on Repair Shear Bond Strength of Aged Silorane-Based Composite

    PubMed Central

    Alizadeh Oskoee, Parnian; Savadi Oskoee, Siavash; Rikhtegaran, Sahand; Pournaghi-Azar, Fatemeh; Gholizadeh, Sarah; Aleyasin, Yasaman; Kasrae, Shahin

    2017-01-01

    Introduction: Successful repair of composite restorations depends on a strong bond between the old composite and the repair composite. This study sought to assess the repair shear bond strength of aged silorane-based composite following surface treatment with Nd:YAG, Er,Cr:YSGG and CO2 lasers. Methods: Seventy-six Filtek silorane composite cylinders were fabricated and aged by 2 months of water storage at 37°C. The samples were randomly divided into 4 groups (n=19) of no surface treatment (group 1) and surface treatment with Er,Cr:YSGG (group 2), Nd:YAG (group 3) and CO2 (group 4) lasers. The repair composite was applied and the shear bond strength was measured. The data were analyzed using one-way analysis of variance (ANOVA) and Tukey posthoc test. Prior to the application of the repair composite, 2 samples were randomly selected from each group and topographic changes on their surfaces following laser irradiation were studied using a scanning electron microscope (SEM). Seventeen other samples were also fabricated for assessment of cohesive strength of composite. Results: The highest and the lowest mean bond strength values were 8.99 MPa and 6.69 MPa for Er,Cr:YSGG and control groups, respectively. The difference in the repair bond strength was statistically significant between the Er,Cr:YSGG and other groups. Bond strength of the control, Nd:YAG and CO2 groups was not significantly different. The SEM micrographs revealed variable degrees of ablation and surface roughness in laser-treated groups. Conclusion: Surface treatment with Er,Cr:YSGG laser significantly increase the repair bond strength of aged silorane-based composite resin. PMID:29071025

  1. An experimental approach to free vibration analysis of smart composite beam

    NASA Astrophysics Data System (ADS)

    Yashavantha Kumar, G. A.; Sathish Kumar, K. M.

    2018-02-01

    Experimental vibration analysis is a main concern of this study. In designing any structural component the important parameter that has to be considered is vibration. The present work involves the experimental investigation of free vibration analysis of a smart beam. Smart beam consists of glass/epoxy composite as a main substrate and two PZT patches. The PZT patches are glued above and below the main beam. By experimentation the natural frequencies and mode shapes are obtained for both with and without PZT patches of a beam. Finally through experimentation the response of the smart beam is recorded.

  2. [Right branch pulmonary artery stenosis with supravalvar aortic stenosis as a complication of Lecompte maneuver for tetralogy of Fallot associated with absent pulmonary valve].

    PubMed

    Honda, Yoshihiro; Suzuki, Shoji; Kaga, Shigeaki; Yoshida, Yukiyo; Kimura, Mitsuhiro; Kamiya, Kentaro; Sakakibara, Kenji; Katsu, Masatake

    2015-05-01

    The patient was diagnosed with tetralogy of Fallot associated with absent pulmonary valve syndrome and a low birth weight of 1,912 g. He suffered from respiratory distress on day 14 and received non-invasive positive pressure ventilation. At 5 months of age and 4.1 kg, he underwent intracardiac repair including right ventricular outflow repair with a monocusp patch, patch closure of the ventricular septum defect and right pulmonary transposition to the anterior of the ascending aorta following the Lecompte maneuver for airway decompression. He was subsequently discharged to home and exhibited an uneventful clinical course with non-invasive positive pressure ventilation for 5 months postoperatively. However, right pulmonary artery and supra-aortic stenosis was noted 2 years after the operation. Computed tomography (CT) and angiography showed ascending aorta strangulation by the right pulmonary artery with right ventricular outflow regurgitation. Right pulmonary artery reconstruction using polytetrafluoroethylene graft interposition and repeat right ventricular outflow repair with bicuspid hand-sewn valves was therefore performed;the postoperative course was uneventful. Pre- and post-operative management using non-invasive positive pressure ventilation and airway decompression with pulmonary artery translocation is a useful strategy in patients exhibiting symptomatic tetralogy of Fallot associated with absent pulmonary valve syndrome in the neonatal period.

  3. Strand displacement synthesis by yeast DNA polymerase ε

    PubMed Central

    Ganai, Rais A.; Zhang, Xiao-Ping; Heyer, Wolf-Dietrich; Johansson, Erik

    2016-01-01

    DNA polymerase ε (Pol ε) is a replicative DNA polymerase with an associated 3′–5′ exonuclease activity. Here, we explored the capacity of Pol ε to perform strand displacement synthesis, a process that influences many DNA transactions in vivo. We found that Pol ε is unable to carry out extended strand displacement synthesis unless its 3′–5′ exonuclease activity is removed. However, the wild-type Pol ε holoenzyme efficiently displaced one nucleotide when encountering double-stranded DNA after filling a gap or nicked DNA. A flap, mimicking a D-loop or a hairpin structure, on the 5′ end of the blocking primer inhibited Pol ε from synthesizing DNA up to the fork junction. This inhibition was observed for Pol ε but not with Pol δ, RB69 gp43 or Pol η. Neither was Pol ε able to extend a D-loop in reconstitution experiments. Finally, we show that the observed strand displacement synthesis by exonuclease-deficient Pol ε is distributive. Our results suggest that Pol ε is unable to extend the invading strand in D-loops during homologous recombination or to add more than two nucleotides during long-patch base excision repair. Our results support the hypothesis that Pol ε participates in short-patch base excision repair and ribonucleotide excision repair. PMID:27325747

  4. A new technique for the closure of the lens capsule by laser welding.

    PubMed

    Pini, Roberto; Rossi, Francesca; Menabuoni, Luca; Lenzetti, Ivo; Yoo, Sonia; Parel, Jean-Marie

    2008-01-01

    A new method is presented for the closure of the lens capsule based on laser welding of suitably prepared patches of anterior capsular tissue. Experiments were performed in freshly enucleated porcine eyes. The patches were previously stained with a solution of indocyanine green in sterile water and then welded on the recipient capsule by means of diode laser radiation at 810 nm. The welded tissue revealed mechanical properties comparable to those of healthy tissue. This technique is proposed to repair capsular breaks and to provide the closure of the capsulorhexis in lens refilling procedures.

  5. Analysis of Piezoelectric Actuator for Vibration Control of Composite plate

    NASA Astrophysics Data System (ADS)

    Gomaa, Ahmed R.; Hai, Huang

    2017-07-01

    Vibration analysis is studied numerically in this paper for a simply supported composite plate subjected to external loadings. Vibrations are controlled by using piezoelectric patches. Finite element method (ANSYS) is used for obtaining finite element model of the smart plate structure, a layered composite plate is manufactured experimentally and tested to obtain the structure mechanical properties. Different piezoelectric patch areas and different applied gain voltage effects on vibration attenuation is studied. The numerical solution is compared with the experimental work, a good agreement achieved.

  6. Advanced Technology Composite Fuselage - Repair and Damage Assessment Supporting Maintenance

    NASA Technical Reports Server (NTRS)

    Flynn, B. W.; Bodine, J. B.; Dopker, B.; Finn, S. R.; Griess, K. H.; Hanson, C. T.; Harris, C. G.; Nelson, K. M.; Walker, T. H.; Kennedy, T. C.; hide

    1997-01-01

    Under the NASA-sponsored contracts for Advanced Technology Composite Aircraft Structures (ATCAS) and Materials Development Omnibus Contract (MDOC), Boeing is studying the technologies associated with the application of composite materials to commercial transport fuselage structure. Included in the study is the incorporation of maintainability and repairability requirements of composite primary structure into the design. This contractor report describes activities performed to address maintenance issues in composite fuselage applications. A key aspect of the study was the development of a maintenance philosophy which included consideration of maintenance issues early in the design cycle, multiple repair options, and airline participation in design trades. Fuselage design evaluations considered trade-offs between structural weight, damage resistance/tolerance (repair frequency), and inspection burdens. Analysis methods were developed to assess structural residual strength in the presence of damage, and to evaluate repair design concepts. Repair designs were created with a focus on mechanically fastened concepts for skin/stringer structure and bonded concepts for sandwich structure. Both a large crown (skintstringer) and keel (sandwich) panel were repaired. A compression test of the keel panel indicated the demonstrated repairs recovered ultimate load capability. In conjunction with the design and manufacturing developments, inspection methods were investigated for their potential to evaluate damaged structure and verify the integrity of completed repairs.

  7. Repair of damaged DNA in-vivo. Comprehensive progress report, August 1980-August 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanawalt, P.C.

    1983-07-01

    We have extended our characterization of long patch excision repair (LPER) and have demonstrated that LPER is not mutagenic (or error-prone); that the recA function is required for LPER, at least for its regulation; that the substrate for LPER is produced as a linear (not an exponential) function of uv (254 nm) dose; and that LPER can occur in uvr/sup -/ cells treated with N-methyl-N-nitro-N-nitrosoguanidine (MNNG). We have developed 3 methods for measuring the frequency of interstrand crosslinks in DNA and are now applying these methods to the study of the formation and repair of DNA crosslinks in E.Coli. Wemore » have developed a monoclonal antibody specific for thymine glycol in DNA, and are using it to study the repair of thymine glycol in E. coli.« less

  8. Species Richness Responses to Structural or Compositional Habitat Diversity between and within Grassland Patches: A Multi-Taxon Approach

    PubMed Central

    Lengyel, Szabolcs; Déri, Eszter; Magura, Tibor

    2016-01-01

    Habitat diversity (spatial heterogeneity within and between habitat patches in a landscape, HD) is often invoked as a driver of species diversity at small spatial scales. However, the effect of HD on species richness (SR) of multiple taxa is not well understood. We quantified HD and SR in a wet-dry gradient of open grassland habitats in Hortobágy National Park (E-Hungary) and tested the effect of compositional and structural factors of HD on SR of flowering plants, orthopterans, true bugs, spiders, ground beetles and birds. Our dataset on 434 grassland species (170 plants, 264 animals) showed that the wet-dry gradient (compositional HD at the between-patch scale) was primarily related to SR in orthopterans, ground-dwelling arthropods, and all animals combined. The patchiness, or plant association richness, of the vegetation (compositional HD at the within-patch scale) was related to SR of vegetation-dwelling arthropods, whereas vegetation height (structural HD at the within-patch scale) was related to SR of ground-dwelling arthropods and birds. Patch area was related to SR only in birds, whereas management (grazing, mowing, none) was related to SR of plants and true bugs. All relationships between HD and SR were positive, indicating increasing SR with increasing HD. However, total SR was not related to HD because different taxa showed similar positive responses to different HD variables. Our findings, therefore, show that even though HD positively influences SR in a wide range of grassland taxa, each taxon responds to different compositional or structural measures of HD, resulting in the lack of a consistent relationship between HD and SR when taxon responses are pooled. The idiosyncratic responses shown here exemplify the difficulties in detecting general HD-SR relationships over multiple taxa. Our results also suggest that management and restoration aimed specifically to sustain or increase the diversity of habitats are required to conserve biodiversity in complex landscapes. PMID:26901569

  9. Fabrication of tissue engineered tympanic membrane patches using computer-aided design and injection molding.

    PubMed

    Hott, Morgan E; Megerian, Cliff A; Beane, Rich; Bonassar, Lawrence J

    2004-07-01

    The goal of the current study was to use computer-aided design and injection molding technologies to tissue engineer precisely shaped cartilage in the shape of butterfly tympanic membrane patches out of chondrocyte-seeded calcium alginate gels. Molds were designed on SolidWorks 2000 and built out of acrylonitrile butadiene styrene (ABS) using fused deposition modeling (FDM). Tympanic membrane patches were fabricated using bovine articular chondrocytes seeded at 50 x 10 cells/mL in 2% calcium alginate gels. Molded patches were cultured in vitro for up to 10 weeks and assessed biochemically, morphologically, and histologically. Unmolded patches demonstrated outstanding dimensional fidelity, with a volumetric precision of at least 3 microL, and maintained their shape well for up to 10 weeks of in vitro culture. Glycosaminoglycan and collagen content increased steadily over 10 weeks in culture, demonstrating continual deposition of new extracellular matrix consistent with new tissue development. The use of computer-aided design and injection molding technologies allows for the fabrication of very small, precisely shaped chondrocyte-seeded calcium alginate structures that faithfully maintain their shape during in vitro culture. In vitro fabrication of tympanic membrane patches with a precisely controlled geometry may have the potential to provide a minimally invasive alternative to traditional methods for the repair of chronic tympanic membrane perforations.

  10. Process Optimization of Bismaleimide (BMI) Resin Infused Carbon Fiber Composite

    NASA Technical Reports Server (NTRS)

    Ehrlich, Joshua W.; Tate, LaNetra C.; Cox, Sarah B.; Taylor, Brian J.; Wright, M. Clara; Faughnan, Patrick D.; Batterson, Lawrence M.; Caraccio, Anne J.; Sampson, Jeffery W.

    2013-01-01

    Engineers today are presented with the opportunity to design and build the next generation of space vehicles out of the lightest, strongest, and most durable materials available. Composites offer excellent structural characteristics and outstanding reliability in many forms that will be utilized in future aerospace applications including the Commercial Crew and Cargo Program and the Orion space capsule. NASA's Composites for Exploration (CoEx) project researches the various methods of manufacturing composite materials of different fiber characteristics while using proven infusion methods of different resin compositions. Development and testing on these different material combinations will provide engineers the opportunity to produce optimal material compounds for multidisciplinary applications. Through the CoEx project, engineers pursue the opportunity to research and develop repair patch procedures for damaged spacecraft. Working in conjunction with Raptor Resins Inc., NASA engineers are utilizing high flow liquid infusion molding practices to manufacture high-temperature composite parts comprised of intermediate modulus 7 (IM7) carbon fiber material. IM7 is a continuous, high-tensile strength composite with outstanding structural qualities such as high shear strength, tensile strength and modulus as well as excellent corrosion, creep, and fatigue resistance. IM7 carbon fiber, combined with existing thermoset and thermoplastic resin systems, can provide improvements in material strength reinforcement and deformation-resistant properties for high-temperature applications. Void analysis of the different layups of the IM7 material discovered the largest total void composition within the [ +45 , 90 , 90 , -45 ] composite panel. Tensile and compressional testing proved the highest mechanical strength was found in the [0 4] layup. This paper further investigates the infusion procedure of a low-cost/high-performance BMI resin into an IM7 carbon fiber material and the optical, chemical, and mechanical analyses performed.

  11. Biodiversity conservation in an anthropized landscape: Trees, not patch size drive, bird community composition in a low-input agro-ecosystem.

    PubMed

    Mellink, Eric; Riojas-López, Mónica E; Cárdenas-García, Melinda

    2017-01-01

    One of the most typical agro-ecosystems in the Llanos de Ojuelos, a semi-arid region of central Mexico, is that of fruit-production orchards of nopales (prickly pear cacti). This perennial habitat with complex vertical structure provides refuge and food for at least 112 species of birds throughout the year. Nopal orchards vary in their internal structure, size and shrub/tree composition, yet these factors have unknown effects on the animals that use them. To further understand the conservation potential of this agro-ecosystem, we evaluated the effects of patch-size and the presence of trees on bird community composition, as well as several habitat variables, through an information-theoretical modelling approach. Community composition was obtained through a year of census transects in 12 orchards. The presence of trees in the orchards was the major driver of bird communities followed by seasonality; bird communities are independent of patch size, except for small orchard patches that benefit black-chin sparrows, which are considered a sensitive species. At least 55 species of six trophic guilds (insectivores, granivores, carnivores, nectivores, omnivores, and frugivores) used the orchards. Orchards provide adequate habitat and food resources for several sensitive species of resident and migratory sparrows. The attributes that make orchards important for birds: trees, shrubs, herb seeds, and open patches can be managed to maintain native biodiversity in highly anthropized regions with an urgent need to find convergence between production and biological conservation.

  12. Biodiversity conservation in an anthropized landscape: Trees, not patch size drive, bird community composition in a low-input agro-ecosystem

    PubMed Central

    Mellink, Eric; Cárdenas-García, Melinda

    2017-01-01

    One of the most typical agro-ecosystems in the Llanos de Ojuelos, a semi-arid region of central Mexico, is that of fruit-production orchards of nopales (prickly pear cacti). This perennial habitat with complex vertical structure provides refuge and food for at least 112 species of birds throughout the year. Nopal orchards vary in their internal structure, size and shrub/tree composition, yet these factors have unknown effects on the animals that use them. To further understand the conservation potential of this agro-ecosystem, we evaluated the effects of patch-size and the presence of trees on bird community composition, as well as several habitat variables, through an information-theoretical modelling approach. Community composition was obtained through a year of census transects in 12 orchards. The presence of trees in the orchards was the major driver of bird communities followed by seasonality; bird communities are independent of patch size, except for small orchard patches that benefit black-chin sparrows, which are considered a sensitive species. At least 55 species of six trophic guilds (insectivores, granivores, carnivores, nectivores, omnivores, and frugivores) used the orchards. Orchards provide adequate habitat and food resources for several sensitive species of resident and migratory sparrows. The attributes that make orchards important for birds: trees, shrubs, herb seeds, and open patches can be managed to maintain native biodiversity in highly anthropized regions with an urgent need to find convergence between production and biological conservation. PMID:28686608

  13. Process-Driven Ecological Modeling for Landscape Change Analysis

    NASA Astrophysics Data System (ADS)

    Altman, S.; Reif, M. K.; Swannack, T. M.

    2013-12-01

    Landscape pattern is an important driver in ecosystem dynamics and can control system-level functions such as nutrient cycling, connectivity, biodiversity and carbon sequestration. However, the links between process, pattern and function remain ambiguous. Understanding the quantitative relationship between ecological processes and landscape pattern across temporal and spatial scales is vital for successful management and implementation of ecosystem-level projects. We used remote sensing imagery to develop critical landscape metrics to understand the factors influencing landscape change. Our study area, a coastal area in southwest Florida, is highly dynamic with critically eroding beaches and a range of natural and developed land cover types. Hurricanes in 2004 and 2005 caused a breach along the coast of North Captiva Island that filled in by 2010. We used a time series of light detection and ranging (lidar) elevation data and hyperspectral imagery from 2006 and 2010 to determine land cover changes. Landscape level metrics used included: Largest Patch Index, Class Area, Area-weighted mean area, Clumpiness, Area-weighted Contiguity Index, Number of Patches, Percent of landcover, Area-weighted Shape. Our results showed 1) 27% increase in sand/soil class as the channel repaired itself and shoreline was reestablished, 2) 40% decrease in the mudflat class area due to conversion to sand/soil and water, 3) 30% increase in non-wetland vegetation class as a result of new vegetation around the repaired channel, and 4) the water class only slightly increased though there was a marked increase in the patch size area. Thus, the smaller channels disappeared with the infilling of the channel, leaving much larger, less complex patches behind the breach. Our analysis demonstrated that quantification of landscape pattern is critical to linking patterns to ecological processes and understanding how both affect landscape change. Our proof of concept indicated that ecological processes can correlate to landscape pattern and that ecosystem function changes significantly as pattern changes. However, the number of links between landscape metrics and ecological processes are highly variable. Extensively studied processes such as biodiversity can be linked to numerous landscape metrics. In contrast, correlations between sediment cycling and landscape pattern have only been evaluated for a limited number of metrics. We are incorporating these data into a relational database linking landscape and ecological patterns, processes and metrics. The database will be used to parameterize site-specific landscape evolution models projecting how landscape pattern will change as a result of future ecosystem restoration projects. The model is a spatially-explicit, grid-based model that projects changes in community composition based on changes in soil elevations. To capture scalar differences in landscape change, local and regional landscape metrics are analyzed at each time step and correlated with ecological processes to determine how ecosystem function changes with scale over time.

  14. Patterns of vegetation and grasshopper community composition.

    PubMed

    Kemp, W P; Harvey, S J; O'Neill, K M

    1990-06-01

    A study was conducted to evaluate differences in rangeland grasshopper communities over environmental gradients in Gallatin Valley, Montana, USA. The concept of habitat type (Daubenmire 1966) was used as a basis for discriminating between groupings of patches based on vegetation. A total of 39 patches were selected that represented five recognized grassland habitat types (Mueggler and Stewart 1980), as well as two disturbed types (replanting within a known habitat type). Repeated sampling in 1988 of both the insect and plant communities yielded a total of 40 grasshopper (19 664 individuals) and 97 plant species. Detrended Correspondence Analysis (DCA) indicated that patch classifications based on presence and percent cover of plants were appropriate and showed good between-group (habitat type) separation for patches along gradients of precipitation/elevation and plant community complexity. Results from undisturbed habitats showed that plant and grasshopper species composition changed over observed environmental gradients and suggested that habitat type influenced not only species presence, but also relative abundance. Discussion is presented that relates results with patch-use and core and satellite species paradigms.

  15. 3D modelling of squeeze flow of unidirectional and fabric composite inserts

    NASA Astrophysics Data System (ADS)

    Ghnatios, Chady; Abisset-Chavanne, Emmanuelle; Chinesta, Francisco; Keunings, Roland

    2016-10-01

    The enhanced design flexibility provided to the thermo-forming of thermoplastic materials arises from the use of both continuous and discontinuous thermoplastic prepregs. Discontinuous prepregs are patches used to locally strengthen the part. In this paper, we propose a new modelling approach for suspensions involving composite patches that uses theoretical concepts related to discontinuous fibres suspensions, transversally isotropic fluids and extended dumbbell models.

  16. Fistula repair after hypospadias surgery using buccal mucosal graft.

    PubMed

    Hosseini, Jalil; Kaviani, Ali; Mohammadhosseini, Mojtaba; Rezaei, Alireza; Rezaei, Iraj; Javanmard, Babak

    2009-01-01

    The aim of this study was to evaluate the success rate of urethrocutaneous fistula repair using buccal mucosal graft in patients with a previous hypospadias repair. We reviewed records of our patients with urethrocutaneous fistula developed after hypospadias repair in whom buccal mucosal graft fistula repair had been performed. All of the patients had been followed up for 24 postoperative months. A successful surgical operation was defined as no fistula recurrence or urethral stricture. Retrograde urethrography and urethrocystoscopy would be performed in patients who had any history of decreased force and caliber of urine or any difficulty in urination. Fistula repair using buccal mucosa patch graft had been done in 14 children with urethrocutaneous fistula developing after hypospadias reconstruction. The mean age of the children was 8.70 +/- 1.99 years old (range, 4 to 11 years). Seven fistulas were in the midshaft, 4 were in the penoscrotal region, and 3 were in the coronal region. Repair of the fistulas was successful in 11 of 14 patients (78.6%). In the remaining children, the diameter of the fistula was smaller than that before the operation, offering a good opportunity for subsequent closure. Our findings showed that fistula repair using buccal mucosal graft can be one of the acceptable techniques for repairing fistulas developed after hypospadias repair.

  17. Hierarchical spatial segregation of two Mediterranean vole species: the role of patch-network structure and matrix composition.

    PubMed

    Pita, Ricardo; Lambin, Xavier; Mira, António; Beja, Pedro

    2016-09-01

    According to ecological theory, the coexistence of competitors in patchy environments may be facilitated by hierarchical spatial segregation along axes of environmental variation, but empirical evidence is limited. Cabrera and water voles show a metapopulation-like structure in Mediterranean farmland, where they are known to segregate along space, habitat, and time axes within habitat patches. Here, we assess whether segregation also occurs among and within landscapes, and how this is influenced by patch-network and matrix composition. We surveyed 75 landscapes, each covering 78 ha, where we mapped all habitat patches potentially suitable for Cabrera and water voles, and the area effectively occupied by each species (extent of occupancy). The relatively large water vole tended to be the sole occupant of landscapes with high habitat amount but relatively low patch density (i.e., with a few large patches), and with a predominantly agricultural matrix, whereas landscapes with high patch density (i.e., many small patches) and low agricultural cover, tended to be occupied exclusively by the small Cabrera vole. The two species tended to co-occur in landscapes with intermediate patch-network and matrix characteristics, though their extents of occurrence were negatively correlated after controlling for environmental effects. In combination with our previous studies on the Cabrera-water vole system, these findings illustrated empirically the occurrence of hierarchical spatial segregation, ranging from within-patches to among-landscapes. Overall, our study suggests that recognizing the hierarchical nature of spatial segregation patterns and their major environmental drivers should enhance our understanding of species coexistence in patchy environments.

  18. Asphalt Raking. Instructor Manual. Trainee Manual.

    ERIC Educational Resources Information Center

    Laborers-AGC Education and Training Fund, Pomfret Center, CT.

    This packet consists of the instructor and trainee manuals for an asphalt raking course. The instructor manual contains a course schedule for 4 days of instruction, content outline, and instructor outline. The trainee manual is divided into five sections: safety, asphalt basics, placing methods, repair and patching, and clean-up and maintenance.…

  19. Evaluation of epoxy compounds as a material for patching and protecting concrete : final report.

    DOT National Transportation Integrated Search

    1971-01-01

    The final report summarizes the results of a study of the use of epoxy compounds in the shallow surface repair and sealing of concrete bridge decks. The research effort concentrated on the use of epoxy resin systems as bonded overlays and included ev...

  20. Masonry Procedures. Building Maintenance. Module V. Instructor's Guide.

    ERIC Educational Resources Information Center

    Eck, Francis

    This curriculum guide, one of six modules keyed to the building maintenance competency profile developed by industry and education professionals, provides materials for a masonry procedures unit containing eight lessons. Lesson topics are masonry safety practices; set forms; mix concrete; patch and/or repair concrete; pour and finish concrete; mix…

  1. Effect of Landscape Pattern on Insect Species Density within Urban Green Spaces in Beijing, China

    PubMed Central

    Su, Zhimin; Li, Xiaoma; Zhou, Weiqi; Ouyang, Zhiyun

    2015-01-01

    Urban green space is an important refuge of biodiversity in urban areas. Therefore, it is crucial to understand the relationship between the landscape pattern of green spaces and biodiversity to mitigate the negative effects of urbanization. In this study, we collected insects from 45 green patches in Beijing during July 2012 using suction sampling. The green patches were dominated by managed lawns, mixed with scattered trees and shrubs. We examined the effects of landscape pattern on insect species density using hierarchical partitioning analysis and partial least squares regression. The results of the hierarchical partitioning analysis indicated that five explanatory variables, i.e., patch area (with 19.9% independent effects), connectivity (13.9%), distance to nearest patch (13.8%), diversity for patch types (11.0%), and patch shape (8.3%), significantly contributed to insect species density. With the partial least squares regression model, we found species density was negatively related to patch area, shape, connectivity, diversity for patch types and proportion of impervious surface at the significance level of p < 0.05 and positively related to proportion of vegetated land. Regression tree analysis further showed that the highest species density was found in green patches with an area <500 m2. Our results indicated that improvement in habitat quality, such as patch area and connectivity that are typically thought to be important for conservation, did not actually increase species density. However, increasing compactness (low-edge) of patch shape and landscape composition did have the expected effect. Therefore, it is recommended that the composition of the surrounding landscape should be considered simultaneously with planned improvements in local habitat quality. PMID:25793897

  2. Effect of landscape pattern on insect species density within urban green spaces in Beijing, China.

    PubMed

    Su, Zhimin; Li, Xiaoma; Zhou, Weiqi; Ouyang, Zhiyun

    2015-01-01

    Urban green space is an important refuge of biodiversity in urban areas. Therefore, it is crucial to understand the relationship between the landscape pattern of green spaces and biodiversity to mitigate the negative effects of urbanization. In this study, we collected insects from 45 green patches in Beijing during July 2012 using suction sampling. The green patches were dominated by managed lawns, mixed with scattered trees and shrubs. We examined the effects of landscape pattern on insect species density using hierarchical partitioning analysis and partial least squares regression. The results of the hierarchical partitioning analysis indicated that five explanatory variables, i.e., patch area (with 19.9% independent effects), connectivity (13.9%), distance to nearest patch (13.8%), diversity for patch types (11.0%), and patch shape (8.3%), significantly contributed to insect species density. With the partial least squares regression model, we found species density was negatively related to patch area, shape, connectivity, diversity for patch types and proportion of impervious surface at the significance level of p < 0.05 and positively related to proportion of vegetated land. Regression tree analysis further showed that the highest species density was found in green patches with an area <500 m2. Our results indicated that improvement in habitat quality, such as patch area and connectivity that are typically thought to be important for conservation, did not actually increase species density. However, increasing compactness (low-edge) of patch shape and landscape composition did have the expected effect. Therefore, it is recommended that the composition of the surrounding landscape should be considered simultaneously with planned improvements in local habitat quality.

  3. Ceramic Adhesive and Methods for On-Orbit Repair of Re-Entry Vehicles

    NASA Technical Reports Server (NTRS)

    Riedell, James A.; Easler, Timothy E.

    2013-01-01

    This adhesive is capable of repairing damaged leading edge components of reentry vehicles while in space, and is novel with regard to its ability to be applied in the vacuum of space, and in a microgravity environment. Once applied, the adhesive provides thermal and oxidation protection to the substrate (in this case, reinforced carbon/carbon composites, RCCs) during re-entry of a space vehicle. Although there may be many formulations for repair adhesives, at the time of this reporting, this is the first known adhesive capable of an on-orbit repair. The adhesive is an engineered ceramic material composed of a pre-ceramic polymer and refractory powders in the form of a paste or putty that can be applied to a scratched, cracked, or fractured composite surface, covering and protecting the damaged area. The adhesive is then "cured" with a heat cycle, thereby cross-linking the polymer into a hardened material and bonding it to the substrate. During the heat of reentry, the material is converted to a ceramic coating that provides thermal and oxidative stability to the repaired area, thus allowing the vehicle to pass safely from space into the upper atmosphere. Ceramic powders such as SiC, ZrB2 and Y2O3 are combined with allylhydridopolycarbosilane (AHPCS) resin, and are mixed to form a paste adhesive. The material is then applied to the damaged area by brush, spatula, trowel, or other means to fill cracks, gaps, and holes, or used to bond patches onto the damaged area. The material is then cured, in a vacuum, preferably at 250F (approximately equal to 121C) for two hours. The re-entry heating of the vehicle at temperatures in excess of 3,000F (approximately equal to 1,650C) then converts this material into a ceramic coating. This invention has demonstrated advantages in resistance to high temperatures, as was demonstrated in more than 100 arc-jet tests in representative environments at NASA. Extensive testing verified oxidation protection for the repaired substrate (RCC), and confirmed that the microstructure of the resulting repair leads to durability and resistance to melting or flow. Its processability and working life in a vacuum was demonstrated by NASA astronauts in glovebox processing studies, as well as on-orbit in the open space shuttle bay. All of these advantages increase the working life of NASA vehicles, as well as improve safety for any crew on a manned vehicle. The adhesive, trademarked NOAX(TM). or Non-Oxide Adhesive Experimental, flew on all space shuttle missions from Return To Flight (STS-114) until the final flight (STS- 135) as a crack repair material for the leading edges and nose cap of the vehicle. NOAX(TM) was patented under U.S. Patents 7,628,878 and 7,888,277.

  4. Development of a robotic system of nonstripping pipeline repair by reinforced polymeric compositions

    NASA Astrophysics Data System (ADS)

    Rybalkin, LA

    2018-03-01

    The article considers the possibility of creating a robotic system for pipeline repair. The pipeline repair is performed due to inner layer formation by special polyurethane compositions reinforced by short glass fiber strands. This approach provides the opportunity to repair pipelines without excavation works and pipe replacement.

  5. Shift in soil microbial communities with shrub encroachment in Inner Mongolia grasslands, China

    NASA Astrophysics Data System (ADS)

    Shen, H.; Li, H.; Zhang, J.; Hu, H.; Chen, L.; Zhu, Y.; Fang, J.

    2017-12-01

    The ongoing expansion of shrub encroachment into grasslands represents a unique form of land cover change. How this process affects soil microbial communities is poorly understood. In this study, we aim to assess the effects of shrub encroachment on soil microbial biomass, abundance and composition by comparing data between shrub patches and neighboring herb patches in shrub-encroached grasslands (SEGs) in Inner Mongolia, China. Fourteen SEG sites from two ecosystem types (typical and desert grasslands) were investigated. The phospholipid fatty acid (PLFA) method was used to analyze the composition and biomass of the soil microbial community. Our results showed that the top-soil microbial biomass and abundances of gram-negative bacteria, arbuscular mycorrhizal fungi, and actinomycetes were significantly higher in shrub patches than in herb patches in both typical and desert grasslands (P < 0.05). The fungi to bacteria ratio was significantly higher in shrub patches than in herb patches in desert grassland (P < 0.05). The microbial biomass was positively associated with mean annual precipitation, total nitrogen and available phosphorus, and negatively associated with mean annual temperature. Our results also indicated that the variation in microbial composition was largely explained by edaphic factors, followed by climate factors. In conclusion, shrub encroachment in Inner Mongolia grasslands has significantly influenced the structure and abundance of soil microbial communities, which makes the microbial communities toward a fresh organic carbon-based structure. This study highlights the importance of edaphic and climate factors in microbial community shifts in SEGs.

  6. Repair or replacement of defective direct resin-based composite restorations: contemporary teaching in U.S. and Canadian dental schools.

    PubMed

    Lynch, Christopher D; Blum, Igor R; Frazier, Kevin B; Haisch, Larry D; Wilson, Nairn H F

    2012-02-01

    Opportunities exist to promote minimally invasive dentistry by repairing rather than replacing defective and failing direct resin-based composite restorations. The authors conducted a study to investigate the current teaching of such techniques in U.S. and Canadian dental schools. In late 2010, the authors, with the assistance of the Consortium of Operative Dentistry Educators, invited 67 U.S. and Canadian dental schools to participate in an Internet-based survey. The response rate was 72 percent. Eighty-eight percent of the dental schools taught repair of defective direct resin-based composite restorations. Of these schools, 79 percent reported providing both didactic and clinical teaching. Although teaching repair of defective resin-based composite restorations was included in the didactic curricula of most schools, students in some schools did not gain experience in minimally invasive management of defective resin-based composite restorations by means of performing repair procedures. The American Dental Association's Code on Dental Procedures and Nomenclature does not have a procedure code for resin-based composite restoration repairs, which may limit patients' access to this dental treatment. Teaching dental students minimally invasive dentistry procedures, including restoration repair, extends the longevity of dental restorations and reduces detrimental effects on teeth induced by invasive procedures, thereby serving the interests of patients.

  7. Injection repair of carbon fiber/bismaleimide composite panels with bisphenol E cyanate ester resin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thunga, Mahendra; Bauer, Amy; Obusek, Kristine

    2014-08-01

    Resin injection of bisphenol E cyanate ester, a low viscosity resin that cures into a high temperature thermoset polymer, is investigated as a reliable repair method to restore strength and stiffness in delaminated carbon fiber/bismaleimide composites used in aircraft panels. The influence of temperature on the viscosity of the uncured resin was measured to optimize the injection conditions for high resin infiltration into the delaminations. The repair efficiency of the resin was evaluated by varying the panel thickness and the method by which the delamination damage was created in the composite specimens. Ultrasonic scanning (C-scan), flash thermography images, and cross-sectionmore » analysis of repaired panels revealed excellent resin infiltration into the damaged region. Evaluation of mechanical repair efficiency using both bending stiffness and in-plain compressive strength of the composite panels as the repair metrics showed values exceeding 100%.« less

  8. Room Temperature Curing Resin Systems for Graphite/Epoxy Composite Repair.

    DTIC Science & Technology

    1979-12-01

    ROOM TEMPERATURE CURING RESIN SYSTEMS FOR GRAPHITE/EPOXY COMPOS--ETC(UI DEC 79 0 J CRABTREE N62269-79-C-G224 UNCLASSIFIE O80-46 NADC -781 1-6 NL END...Room Temperature Curing Resin Sys-U3 linal for Graphite/Epoxy Composite Repair •.Dec *79 NOR- -46h: V111IT NUM8ER(s) 4362269-79- ,722 S. PERFORMING...repair, composite repair room temperature cure resin , moderate temperature cure resins , epoxies, adhesives, vinyl eater polymers, anaerobic curing polymers

  9. Quality of inguinal hernia operative reports: room for improvement

    PubMed Central

    Ma, Grace W.; Pooni, Amandeep; Forbes, Shawn S.; Eskicioglu, Cagla; Pearsall, Emily; Brenneman, Fred D.; McLeod, Robin S.

    2013-01-01

    Background Operative reports (ORs) serve as the official documentation of surgical procedures. They are essential for optimal patient care, physician accountability and billing, and direction for clinical research and auditing. Nonstandardized narrative reports are often of poor quality and lacking in detail. We sought to audit the completeness of narrative inguinal hernia ORs. Methods A standardized checklist for inguinal hernia repair (IHR) comprising 33 variables was developed by consensus of 4 surgeons. Five high-volume IHR surgeons categorized items as essential, preferable or nonessential. We audited ORs for open IHR at 6 academic hospitals. Results We audited 213 ORs, and we excluded 7 femoral hernia ORs. Tension-free repairs were the most common (82.5%), and the plug-and-patch technique was the most frequent (52.9%). Residents dictated 59% of ORs. Of 33 variables, 15 were considered essential and, on average, 10.8 ± 1.3 were included. Poorly reported elements included first occurrence versus recurrent repair (8.3%), small bowel viability in incarcerated hernias (10.7%) and occurrence of intraoperative complications (32.5%). Of 18 nonessential elements, deep vein thrombosis prophylaxis, preoperative antibiotics and urgency were reported in 1.9%, 11.7% and 24.3% of ORs, respectively. Repair-specific details were reported in 0 to 97.1% of ORs, including patch sutured to tubercle (55.1%) and location of plug (67.0%). Conclusion Completeness of IHR ORs varied with regards to essential and nonessential items but were generally incomplete, suggesting there is opportunity for improvement, including implementation of a standardized synoptic OR. PMID:24284146

  10. Far field focusing for a microwave patch antenna with composite substrate

    NASA Astrophysics Data System (ADS)

    Wan, Jian; Rybin, Oleg; Shulga, Sergey

    2018-03-01

    Modeling for a compact microwave antenna structure on base of a miniaturized rectangular patch antenna with composite substrate and magnetic superstrates is made in this study by using FDTD simulations. The resonant frequency of the antenna structure is supposed to be 15 GHz. The design of the antenna with composite substrate and without superstrate is made up by using the microwave miniaturization concept for rectangular patch antennas created by first author of this study. The optimal distance between the superstrate and antenna surface is found by using Fabry-Perot cavity theory as maximum values of power directivity and efficiency of the antenna is achieved. The comparative analysis with regard to some far and near field parameters of the above antenna structures and the antenna with dielectric substrate having same value of the relative permittivity is performed.

  11. Effect of organic solvents compared to sandblasting on the repair bond strength of nanohybrid and nanofilled composite resins.

    PubMed

    Brum, Rafael Torres; Vieira, Sergio; Freire, Andrea; Mazur, Rui Fernando; De Souza, Evelise Machado; Rached, Rodrigo Nunes

    2017-01-01

    This study evaluated the effect of different surface treatments on the repair bond strength of nanohybrid (Empress Direct) and nanofilled (Filtek Z350 XT) composite resins. A total of 120 specimens of each material (7.5 x 4.5 x 3 mm) were prepared and polished with SiC paper. Half of the specimens were kept in water for seven days and the other half for six months; they were then divided into six groups according to the type of surface treatment: negative control (no treatment), Al2O3sandblasted, liquid acetone, acetone gel, liquid alcohol and alcohol gel. Following application of the silane coupling agent and the adhesive system, composite resin cylinders were fabricated on the specimens and light cured (20 seconds). The same composite resins were used for the repair. Additionally, ten intact specimens of each composite resin (without repair) were prepared (positive control). The specimens were then loaded to failure in the microshear mode. Three additional specimens were fabricated in each group, and the surface treatments were analyzed by atomic force microscopy, energy-dispersive X-ray spectroscopy (EDS) and scanning electron microscopy (SEM). The nanofilled composite resin showed higher cohesive strength and repair bond strength than the nanohybrid composite resin. The aging process affected the repair bond strength of the nanofilled composite resin. Al2O3sandblasting was more efficient for the nanofilled composite resin and promoted greater surface roughness in both materials. The solvents demonstrated higher efficacy for the nanohybrid composite resin. The strengths resulting from the solvents were material dependent, and Al2O3sandblasting resulted in superior repair bond strength in both materials.

  12. Repairability of CAD/CAM high-density PMMA- and composite-based polymers.

    PubMed

    Wiegand, Annette; Stucki, Lukas; Hoffmann, Robin; Attin, Thomas; Stawarczyk, Bogna

    2015-11-01

    The study aimed to analyse the shear bond strength of computer-aided design and computer-aided manufacturing (CAD/CAM) polymethyl methacrylate (PMMA)- and composite-based polymer materials repaired with a conventional methacrylate-based composite after different surface pretreatments. Each 48 specimens was prepared from six different CAD/CAM polymer materials (Ambarino high-class, artBloc Temp, CAD-Temp, Lava Ultimate, Telio CAD, Everest C-Temp) and a conventional dimethacrylate-based composite (Filtek Supreme XTE, control) and aged by thermal cycling (5000 cycles, 5-55 °C). The surfaces were left untreated or were pretreated by mechanical roughening, aluminium oxide air abrasion or silica coating/silanization (each subgroup n = 12). The surfaces were further conditioned with an etch&rinse adhesive (OptiBond FL) before the repair composite (Filtek Supreme XTE) was adhered to the surface. After further thermal cycling, shear bond strength was tested, and failure modes were assessed. Shear bond strength was statistically analysed by two- and one-way ANOVAs and Weibull statistics, failure mode by chi(2) test (p ≤ 0.05). Shear bond strength was highest for silica coating/silanization > aluminium oxide air abrasion = mechanical roughening > no surface pretreatment. Independently of the repair pretreatment, highest bond strength values were observed in the control group and for the composite-based Everest C-Temp and Ambarino high-class, while PMMA-based materials (artBloc Temp, CAD-Temp and Telio CAD) presented significantly lowest values. For all materials, repair without any surface pretreatment resulted in adhesive failures only, which mostly were reduced when surface pretreatment was performed. Repair of CAD/CAM high-density polymers requires surface pretreatment prior to adhesive and composite application. However, four out of six of the tested CAD/CAM materials did not achieve the repair bond strength of a conventional dimethacrylate-based composite. Repair of PMMA- and composite-based polymers can be achieved by surface pretreatment followed by application of an adhesive and a conventional methacrylate-based composite.

  13. Habitat structure mediates biodiversity effects on ecosystem properties

    PubMed Central

    Godbold, J. A.; Bulling, M. T.; Solan, M.

    2011-01-01

    Much of what we know about the role of biodiversity in mediating ecosystem processes and function stems from manipulative experiments, which have largely been performed in isolated, homogeneous environments that do not incorporate habitat structure or allow natural community dynamics to develop. Here, we use a range of habitat configurations in a model marine benthic system to investigate the effects of species composition, resource heterogeneity and patch connectivity on ecosystem properties at both the patch (bioturbation intensity) and multi-patch (nutrient concentration) scale. We show that allowing fauna to move and preferentially select patches alters local species composition and density distributions, which has negative effects on ecosystem processes (bioturbation intensity) at the patch scale, but overall positive effects on ecosystem functioning (nutrient concentration) at the multi-patch scale. Our findings provide important evidence that community dynamics alter in response to localized resource heterogeneity and that these small-scale variations in habitat structure influence species contributions to ecosystem properties at larger scales. We conclude that habitat complexity forms an important buffer against disturbance and that contemporary estimates of the level of biodiversity required for maintaining future multi-functional systems may need to be revised. PMID:21227969

  14. Habitat structure mediates biodiversity effects on ecosystem properties.

    PubMed

    Godbold, J A; Bulling, M T; Solan, M

    2011-08-22

    Much of what we know about the role of biodiversity in mediating ecosystem processes and function stems from manipulative experiments, which have largely been performed in isolated, homogeneous environments that do not incorporate habitat structure or allow natural community dynamics to develop. Here, we use a range of habitat configurations in a model marine benthic system to investigate the effects of species composition, resource heterogeneity and patch connectivity on ecosystem properties at both the patch (bioturbation intensity) and multi-patch (nutrient concentration) scale. We show that allowing fauna to move and preferentially select patches alters local species composition and density distributions, which has negative effects on ecosystem processes (bioturbation intensity) at the patch scale, but overall positive effects on ecosystem functioning (nutrient concentration) at the multi-patch scale. Our findings provide important evidence that community dynamics alter in response to localized resource heterogeneity and that these small-scale variations in habitat structure influence species contributions to ecosystem properties at larger scales. We conclude that habitat complexity forms an important buffer against disturbance and that contemporary estimates of the level of biodiversity required for maintaining future multi-functional systems may need to be revised.

  15. Two layer structure for reinforcing pothole repair

    NASA Astrophysics Data System (ADS)

    Yuan, Wei; Yuan, Kuo-Yao; Zou, Linhua; Yang, Jenn-Ming; Ju, Jiann-Wen; Kao, Wei; Carlson, Larry

    2013-04-01

    We have applied dicyclopentadiene (DCPD) resin for reinforcing pothole patch materials due to its unique properties - low cost, low viscosity at beginning and ultra-toughness after curing, chemical compatibility with tar, tunable curing profile through catalyst design. In this paper, we have designed a two layer structure - well compacted base layer and DCPD reinforced 1-1.5" top layer - for pothole repair. By choosing two graded asphalt mixes, a porous top layer and fully compacted base layer was prepared after compaction and ready for DCPD resin infiltration. The DCPD curing and infiltration profile within this porous top layer was measured with thermocouples. The rutting resistance was tested with home-made wheel rutter. The cage effect due to the p-DCPD wrapping was characterized with wheel penetration test. The results showed that this two layer structure pothole repair has greatly improved properties and can be used for pothole repair to increase the service life.

  16. Influence of different repair procedures on bond strength of adhesive filling materials to etched enamel in vitro.

    PubMed

    Hannig, Christian; Hahn, Petra; Thiele, Patrick-Philipp; Attin, Thomas

    2003-01-01

    Contamination of etched enamel with repair bond agents during repair of dental restorations may interfere with the bonding of composite to enamel. This study examined the bond strength of adhesive filling materials to etched bovine enamel after pre-treatment with the repair systems Monobond S, Silibond and Co-Jet. The materials Tetric Ceram, Dyract and Definite and their corresponding bonding agents (Syntac Single Comp, Prime & Bond NT, Etch and Prime) were tested in combination with the repair systems. One hundred and thirty-five enamel specimens were etched (37% phosphoric acid, 60 seconds) and equally distributed among three groups (A-C). In Group A, the repair materials were applied on etched enamel followed by applying the composite materials without using their respective bonding material. In Group B, the composite materials were placed on etched enamel after applying the repair materials and bonding agents. In control Group C, the composite materials and bonding agents were applied on etched enamel without using the repair systems. In each sub-group, every composite material was applied on 15 specimens. Samples were stored in artificial saliva for 14 days and thermocycled 1,000 times (5 degrees C/55 degrees C). The shear bond strength of the samples were then determined in a universal testing machine (ISO 10477). Applying Monobond or Silibond followed by the use of its respective bonding agents resulted in a bond strength that was not statistically different from the controls for all filling materials (Group C). The three composites that used Monobond and Silibond without applying the corresponding bonding agent resulted in bond strengths that were significantly lower than the controls. Utilizing the Co-Jet-System drastically reduced the bond strength of composites on etched enamel. Contamination of etched enamel with the repairing bonding agents Monobond and Silibond does not interfere with bond strength if the application of Monobond and Silibond is followed by using its corresponding bonding system of the composites tested.

  17. Creep Forming of Carbon-Reinforced Ceramic-Matrix Composites

    NASA Technical Reports Server (NTRS)

    Vaughn, Wallace L.; Scotti, Stephan J.; Ashe, Melissa P.; Connolly, Liz

    2007-01-01

    A set of lecture slides describes an investigation of creep forming as a means of imparting desired curvatures to initially flat stock plates of carbon-reinforced ceramic-matrix composite (C-CMC) materials. The investigation is apparently part of a continuing effort to develop improved means of applying small CCMC repair patches to reinforced carbon-carbon leading edges of aerospace vehicles (e.g., space shuttles) prior to re-entry into the atmosphere of the Earth. According to one of the slides, creep forming would be an intermediate step in a process that would yield a fully densified, finished C-CMC part having a desired size and shape (the other steps would include preliminary machining, finish machining, densification by chemical vapor infiltration, and final coating). The investigation included experiments in which C-CMC disks were creep-formed by heating them to unspecified high temperatures for time intervals of the order of 1 hour while they were clamped into single- and double-curvature graphite molds. The creep-formed disks were coated with an oxidation- protection material, then subjected to arc-jet tests, in which the disks exhibited no deterioration after exposure to high-temperature test conditions lasting 490 seconds.

  18. Does the light source affect the repairability of composite resins?

    PubMed

    Karaman, Emel; Gönülol, Nihan

    2014-01-01

    The aim of this study was to examine the effect of the light source on the microshear bond strength of different composite resins repaired with the same substrate. Thirty cylindrical specimens of each composite resin--Filtek Silorane, Filtek Z550 (3M ESPE), Gradia Direct Anterior (GC), and Aelite Posterior (BISCO)--were prepared and light-cured with a QTH light curing unit (LCU). The specimens were aged by thermal cycling and divided into three subgroups according to the light source used--QTH, LED, or PAC (n = 10). They were repaired with the same substrate and a Clearfil Repair Kit (Kuraray). The specimens were light-cured and aged for 1 week in distilled water at 37 °C. The microshear bond strength and failure modes were assessed. There was no significant difference in the microshear bond strength values among the composite resins, except for the Filtek Silorane group that showed significantly lower bond strength values when polymerized with the PAC unit compared to the QTH or LED unit. In conclusion, previously placed dimethacrylate-based composites can be repaired with different light sources; however, if the composite to be repaired is silorane-based, then using a QTH or LED device may be the best option.

  19. The Microwave Assisted Composite Manufacturing and Repair (MACMAR) Project

    NASA Technical Reports Server (NTRS)

    Falker, John; Terrier, Douglas; Clayton, Ronald G.; Worthy, Erica; Sosa, Edward

    2015-01-01

    The inherent microwave property of carbon nanotubes (CNTs) generates the thermal energy required to induce reversible polymerization of the matrix in these self-healing composites. Microwaves will be used to demonstrate advanced composite manufacturing and repair using self-healing composites.

  20. The management of defective resin composite restorations: current trends in dental school teaching in Japan.

    PubMed

    Lynch, C D; Hayashi, M; Seow, L L; Blum, I R; Wilson, N H F

    2013-01-01

    The aim of this article is to investigate the contemporary teaching of the management of defective direct resin composite restorations in dental schools in Japan. A questionnaire relating to the teaching of the management of defective resin composite restorations was developed and e-mailed to 29 dental schools in Japan in 2010. Completed responses were received from 19 of the 29 invited schools (response rate = 66%). Eighteen schools (95%) report that they included the teaching of repair of direct defective resin composite restorations in their dental school programs. Thirteen schools reported that they included both clinical and didactic instruction on the repair of direct resin composite restorations. Fourteen schools did not teach any mechanical roughening of the exposed resin composite restoration surface before undertaking a repair. The most commonly reported treatment was acid etching with phosphoric acid (12 schools). The most commonly taught material for completing repairs was a flowable resin composite (16 schools). The teaching of repair of defective resin composite restorations is well established within many Japanese dental schools, to a greater extent than in some other regions of the world. The impact of this teaching on subsequent clinical practices in Japan should be investigated. Furthermore, it is concluded that there is a need for much stronger leadership in operative and conservative dentistry, ideally at the global level, to resolve differences in key aspects of operative procedures such as repairs.

  1. Indirect facilitation becomes stronger with seedling age in a degraded seasonally dry forest

    NASA Astrophysics Data System (ADS)

    Torres, Romina C.; Renison, Daniel

    2016-01-01

    In seasonally dry forests direct facilitation by woody species due to amelioration of harsh abiotic conditions could be important during germination and early establishment of tree seedlings, and under some species but not others. Recent research suggests that at later stages facilitation by woody species may be indirect due to protection of saplings from herbivores, implying that under absence of herbivores reforestation programs may plant saplings in unprotected open sites. We used the native tree Lithraea molleoides from central Argentina as a model species to test this hypothesis. We performed a seeding and planting experiment simulating early and late establishment respectively, which included 234 study plots situated in herbaceous, shrub and tree patches of differing species composition and under two herbivore treatments (grazed and ungrazed) and replicated at three sites. Seedling counts averaged 0.82% of the sown seeds after 6 months, were highest under shrubs and lowest in open patches, and were influenced by woody species composition only in tree patches (all P values < 0.05). At seedling stages we detected no influence of herbivory (P = 0.4) nor of indirect facilitation due to herbivory (herbivory × patch type P = 0.7). Survival of planted saplings was 53% after 3 years and over winter dieback affected 76% of the saplings. At sapling stages we found an increasing importance of indirect facilitation through protection from herbivores, as we recorded the highest sapling survival and growth at tree and shrub patches and the lowest in open patches (all P values < 0.001), and a negative effect of livestock (P < 0.001) mainly on the open patches (herbivory × patch type P = 0.07 and P = 0.001 for survival and growth, respectively). We found no significant influence of woody species composition on sapling survival and growth (all P values > 0.05). We conclude that direct facilitation is involved at all studied stages while indirect facilitation becomes increasingly important at the sapling stage.

  2. Strand displacement synthesis by yeast DNA polymerase ε.

    PubMed

    Ganai, Rais A; Zhang, Xiao-Ping; Heyer, Wolf-Dietrich; Johansson, Erik

    2016-09-30

    DNA polymerase ε (Pol ε) is a replicative DNA polymerase with an associated 3'-5' exonuclease activity. Here, we explored the capacity of Pol ε to perform strand displacement synthesis, a process that influences many DNA transactions in vivo We found that Pol ε is unable to carry out extended strand displacement synthesis unless its 3'-5' exonuclease activity is removed. However, the wild-type Pol ε holoenzyme efficiently displaced one nucleotide when encountering double-stranded DNA after filling a gap or nicked DNA. A flap, mimicking a D-loop or a hairpin structure, on the 5' end of the blocking primer inhibited Pol ε from synthesizing DNA up to the fork junction. This inhibition was observed for Pol ε but not with Pol δ, RB69 gp43 or Pol η. Neither was Pol ε able to extend a D-loop in reconstitution experiments. Finally, we show that the observed strand displacement synthesis by exonuclease-deficient Pol ε is distributive. Our results suggest that Pol ε is unable to extend the invading strand in D-loops during homologous recombination or to add more than two nucleotides during long-patch base excision repair. Our results support the hypothesis that Pol ε participates in short-patch base excision repair and ribonucleotide excision repair. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.

  3. How do patch quality and spatial context affect invertebrate communities in a natural moss microlandscape?

    NASA Astrophysics Data System (ADS)

    Trekels, Hendrik; Driesen, Mario; Vanschoenwinkel, Bram

    2017-11-01

    Globally, moss associated invertebrates remain poorly studied and it is largely unknown to what extent their diversity is driven by local environmental conditions or the landscape context. Here, we investigated small scale drivers of invertebrate communities in a moss landscape in a temperate forest in Western Europe. By comparing replicate quadrats of 5 different moss species in a continuous moss landscape, we found that mosses differed in invertebrate density and community composition. Although, in general, richness was similar among moss species, some invertebrate taxa were significantly linked to certain moss species. Only moss biomass and not relative moisture content could explain differences in invertebrate densities among moss species. Second, we focused on invertebrate communities associated with the locally common moss species Kindbergia praelonga in isolated moss patches on dead tree trunks to look at effects of patch size, quality, heterogeneity and connectivity on invertebrate communities. Invertebrate richness was higher in patches under closed canopies than under more open canopies, presumably due to the higher input of leaf litter and/or lower evaporation. In addition, increased numbers of other moss species in the same patch seemed to promote invertebrate richness in K. praelonga, possibly due to mass effects. Since invertebrate richness was unaffected by patch size and isolation, dispersal was probably not limiting in this system with patches separated by tens of meters, or stochastic extinctions may be uncommon. Overall, we conclude that invertebrate composition in moss patches may not only depend on local patch conditions, in a particular moss species, but also on the presence of other moss species in the direct vicinity.

  4. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  5. The $7-Billion Patch for Campus Maintenance

    ERIC Educational Resources Information Center

    Carlson, Scott

    2009-01-01

    Colleges are facing a growing deferred-maintenance problem, which at many public institutions adds up to repair bills in the hundreds of millions of dollars. Sometimes state legislatures have not supported those colleges at levels needed to maintain campus infrastructure. But at the same time, colleges continue to expand their campuses even as…

  6. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  7. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  8. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  9. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  10. Repair of pig dura in vivo using temperature controlled CO(2) laser soldering.

    PubMed

    Forer, Boaz; Vasilyev, Tamar; Brosh, Tamar; Kariv, Noam; Gil, Ziv; Fliss, Dan M; Katzir, Abraham

    2005-10-01

    The purpose of this study was to demonstrate that laser soldering might be successfully used for closing holes or cuts in the dura layer, which encapsulates the brain. A temperature controlled fiberoptic CO(2) laser system and albumin solder were used for spot soldering of fascia patches to holes in the dura of farm pigs, in vitro and in vivo. The mean burst pressure of the soldered patches in the in vitro experiments was 190 +/- 88 mm Hg-significantly higher than typical maximum CSF pressure of 15 mm Hg. In the in vivo experiments the pigs showed no postoperative complications. Histopathological studies exhibited an accepted level of inflammatory reaction and showed no thermal damage to the underlying brain tissue. It has been clearly demonstrated that temperature controlled laser soldering is a very useful technique for the repair of the dura. It provides significant advantages over standard closure techniques: it is easy to apply, the bond is strong and watertight and the procedure is likely to be much faster than suturing. This research work will lead to clinical trials.

  11. Patch dynamics of a foraging assemblage of bees.

    PubMed

    Wright, David Hamilton

    1985-03-01

    The composition and dynamics of foraging assemblages of bees were examined from the standpoint of species-level arrival and departure processes in patches of flowers. Experiments with bees visiting 4 different species of flowers in subalpine meadows in Colorado gave the following results: 1) In enriched patches the rates of departure of bees were reduced, resulting in increases in both the number of bees per species and the average number of species present. 2) The reduction in bee departure rates from enriched patches was due to mechanical factors-increased flower handling time, and to behavioral factors-an increase in the number of flowers visited per inflorescence and in the number of inflorescences visited per patch. Bees foraging in enriched patches could collect nectar 30-45% faster than those foraging in control patches. 3) The quantitative changes in foraging assemblages due to enrichment, in terms of means and variances of species population sizes, fraction of time a species was present in a patch, and in mean and variance of the number of species present, were in reasonable agreement with predictions drawn from queuing theory and studies in island biogeography. 4) Experiments performed with 2 species of flowers with different corolla tube lengths demonstrated that manipulation of resources of differing availability had unequal effects on particular subsets of the larger foraging community. The arrival-departure process of bees on flowers and the immigration-extinction process of species on islands are contrasted, and the value of the stochastic, species-level approach to community composition is briefly discussed.

  12. Partial hammock valve: surgical repair in adulthood.

    PubMed

    Aramendi, José I; Rodríguez, Miguel A; Voces, Roberto; Pérez, Pedro; Rodrigo, David

    2006-09-01

    We describe a forme frustrée of hammock valve involving only the posterior mitral leaflet. Three adult patients were referred to surgery with the diagnosis of severe mitral regurgitation due to fibrosis of the posterior mitral leaflet. The final diagnosis was done intraoperatively. In all of them the posterior leaflet was attached to some accessory papillary muscles arranged en palisade, with three to four fused muscle heads producing restrictive leaflet motion in systole. Repair consisted in division of the papillary muscles, patch augmentation, and ring annuloplasty. This previously unreported lesion is congenital but manifests itself in adulthood.

  13. Management of carotid Dacron patch infection: a case report using median sternotomy for proximal common carotid artery control and in situ polytetrafluoroethylene grafting.

    PubMed

    Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Ceccanei, Gianluca; Pacilè, Maria Antonietta

    2009-01-01

    We report on a 58-year-old male who presented with an enlarging cervical hematoma 3 months following carotid endarterectomy with Dacron patch repair, due to septic disruption of the Dacron patch secondary to presumed infection. The essential features of this case are the control of the proximal common carotid artery gained through a median sternotomy, because the patient was markedly obese with minimal thyromental distance, and the treatment consisting of in situ polytetrafluoroethylene bypass grafting, due to the absence of a suitable autogenous saphenous vein. Median sternotomy is rarely required in case of reintervention for septic false aneurysms and hematomas following carotid endarterectomy but should be considered whenever difficult control of the common carotid artery, when entering the previous cervicotomy, is anticipated. In situ polytetrafluoroethylene grafting can be considered if autogenous vein material is lacking.

  14. Repair vs replacement of direct composite restorations: a survey of teaching and operative techniques in Oceania.

    PubMed

    Brunton, Paul A; Ghazali, Amna; Tarif, Zahidah H; Loch, Carolina; Lynch, Christopher; Wilson, Nairn; Blum, Igor R

    2017-04-01

    To evaluate the teaching and operative techniques for the repair and/or replacement of direct resin-based composite restorations (DCRs) in dental schools in Oceania. A 14-item questionnaire was mailed to the heads of operative dentistry in 16 dental schools in Oceania (Australia, New Zealand, Fiji and Papua New Guinea). The survey asked whether the repair of DCRs was taught within the curriculum; the rationale behind the teaching; how techniques were taught, indications for repair, operative techniques, materials used, patient acceptability, expected longevity and recall systems. All 16 schools participated in the study. Thirteen (81%) reported the teaching of composite repairs as an alternative to replacement. Most schools taught the theoretical and practical aspects of repair at a clinical level only. All 13 schools (100%) agreed on tooth substance preservation being the main reason for teaching repair. The main indications for repair were marginal defects (100%), followed by secondary caries (69%). All 13 schools that performed repairs reported high patient acceptability, and considered it a definitive measure. Only three schools (23%) claimed to have a recall system in place following repair of DCRs. Most respondents either did not know or did not answer when asked about the longevity of DCRs. Repair of DCRs seems to be a viable alternative to replacement, which is actively taught within Oceania. Advantages include it being minimally invasive, preserving tooth structure, and time and money saving. However, standardised guidelines need to be developed and further clinical long-term studies need to be carried out. The decision between replacing or repairing a defective composite restoration tends to be based on what clinicians have been taught, tempered by experience and judgement. This study investigated the current status of teaching and operative techniques of repair of direct composite restorations in dental schools in Oceania. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Vegetation composition and structure of forest patches along urban-rural gradients

    Treesearch

    W.C. Zipperer; G.R. Guntenspergen

    2009-01-01

    The urban landscape is highly altered by human activities and is a mosaic of different land covers and land uses. Imbedded in this are forest patches of different origins (Zipperer et al .• 1997). How these patches influence and are influenced by the urban landscape is of ecological importance when managing the urban forest for ecosystem goods and services.

  16. PEMFs: new post-surgical management in dentristry

    NASA Astrophysics Data System (ADS)

    Tonetti, Luca

    2014-01-01

    Aim of study: the possible effects on dental postsurgical management using small and not invasive devices: RecoveryRx or ActiPatch producted by Bioelectronics company (USA) Materials and methods: review of literature using searching engines Keywords: PEMFs, postsurgical treatment, pain, wound healing, RecoveryRx, ActiPatch Results: Pulsed Electro Magnetic Fields have been used extensively for decades for many conditions and medical disciplines. Imperceptible cell dysfunction that is not corrected early can lead to disease. Fine-tuning can be done daily in only minutes, using pulsed electromagnetic fields (PEMFs). In addition, when there is a known imbalance (when symptoms are present) or there is a known disease or condition, PEMF treatments, used either alone or along with other therapies, can often help cells rebalance dysfunction faster. It is seen in literature that RecoveryRX and ActiPatch improve the cell metabolism, rebalance the membrane potential difference, improve the circulation and the oxigenation of the tissues, acceleration of osteogenesis, acceleration repair of soft tissues, reduce pain. Conclusion: the RecoveryRX and ActiPatch devices could improve the postsurgical healing reducing the patient discomfort.

  17. Two intelligent materials, both of which are self-forming and self-repairing; one also self-senses and recycles

    NASA Astrophysics Data System (ADS)

    Dry, Carolyn M.

    1996-04-01

    Two self-forming and repair polymer cementitious composites were developed over a decade apart by the author. Both relied on a nature based paradigm as a model for building, in particular bone formation, repair, and degradation. For the first composite, the proposed material accreted from the ocean, made from a fluids based chemistry, that of seawater. The land based system was not built in-situ but relied on a man made supply of materials which were self-forming, self-repairing and dissolving. But in both cases a fluid based chemistry was necessary for self-building, repair and recycling of a bone-like composite material.

  18. Repair of dimethacrylate-based composite restorations by a silorane-based composite: a one-year randomized clinical trial.

    PubMed

    Popoff, D A V; Santa Rosa, T T A; Ferreira, R C; Magalhães, C S; Moreira, A N; Mjör, I A

    2012-01-01

    To investigate clinical performance of a low-shrinkage silorane-based composite resin when used for repairing conventional dimethacrylate-based composite restorations. Despite the continued development of resin-based materials, polymerization shrinkage and shrinkage stress still require improvement. A silorane-based monomer system was recently made available for dental restorations. This report refers to the use of this material for making repairs and evaluates the clinical performance of this alternative treatment. One operator repaired the defective dimethacrylate-based composite resin restorations that were randomly assigned to one of two treatment groups: control (n=50) repair with Adper SE Plus (3M/ESPE) and Filtek P60 Posterior Restorative (3M/ESPE), and test (n=50) repair with P90 System Adhesive Self-Etch Primer and Bond (3M/ESPE) and Filtek P90 Low Shrink Posterior Restorative (3M/ESPE). After one week, restorations were finished and polished. Two calibrated examiners (Kw≥0.78) evaluated all repaired restorations, blindly and independently, at baseline and one year. The parameters examined were marginal adaptation, anatomic form, surface roughness, marginal discoloration, postoperative sensitivity, and secondary caries. The restorations were classified as Alpha, Bravo, or Charlie, according to modified US Public Health Service criteria. Mann-Whitney and Wilcoxon tests were used to compare the groups. Of the 100 restorations repaired in this study, 93 were reexamined at baseline. Dropout from baseline to one-year recall was 11%. No statistically significant differences were found between the materials for all clinical criteria, at baseline or at one-year recall (p>0.05). No statistically significant differences were registered (p>0.05) for each material when compared for all clinical criteria at baseline and at one-year recall. The hypothesis tested in this randomized controlled clinical trial was accepted. After the one-year evaluations, the silorane-based composite exhibited a similar performance compared with dimethacrylate-based composite when used to make repairs.

  19. A hydrogel pericardial patch.

    PubMed

    Allder, M A; Guilbeau, E J; Brandon, T A; Walker, A S; Koeneman, J B; Fisk, R L

    1990-01-01

    Patients undergoing repeat cardiac operations are higher operative risks than those undergoing an initial cardiac procedure because adhesion formation can occur if the native pericardium is not closed. A unique composite patch that may be used to augment the pericardial tissue when primary closure is not possible has been developed. The patch is made of a hydrogel, poly (2-hydroxyethyl methacrylate), reinforced with an ethylene tetrafluoroethylene (ETFE) mesh. The mesh provides the needed mechanical properties, whereas the patch's surface properties are comparable to the hydrogel. Two types of patches were fabricated: one with the mesh weave at a perpendicular orientation and one at 45 degrees to the principle loading direction. The patches were mechanically tested and compared with canine pericardium. Ultimate tensile strength of the patches is not significantly different from canine pericardium (p less than 0.05), are the patch suture strength is nearly twice that of canine pericardium. The perpendicular patch is stiffer than canine pericardium, whereas the 45 degree patch is not (p less than 0.05). The 45 degree patch shows considerable promise as a pericardial substitute because it closely matches the properties native canine pericardium.

  20. MG53-mediated cell membrane repair protects against acute kidney injury

    PubMed Central

    Lin, Peihui; Tan, Tao; Wang, Zhen; Chen, Ken; Zhou, Xinyu; Gumpper, Kristyn; Zhu, Hua; Ludwig, Thomas; Mohler, Peter J.; Rovin, Brad; Abraham, William T.; Zeng, Chunyu; Ma, Jianjie

    2015-01-01

    Injury to the renal proximal tubular epithelium (PTE) represents the underlying consequence of acute kidney injury (AKI) after exposure to various stressors, including nephrotoxins and ischemia/reperfusion (I/R). Although the kidney has the ability to repair itself after mild injury, insufficient repair of PTE cells may trigger inflammatory and fibrotic responses, leading to chronic renal failure. We report that MG53, a member of the TRIM family of proteins, participates in repair of injured PTE cells and protects against the development of AKI. We show that MG53 translocates to acute injury sites on PTE cells and forms a repair patch. Ablation of MG53 leads to defective membrane repair. MG53-deficient mice develop pronounced tubulointerstitial injury and increased susceptibility to I/R-induced AKI compared to wild-type mice. Recombinant human MG53 (rhMG53) protein can target injury sites on PTE cells to facilitate repair after I/R injury or nephrotoxin exposure. Moreover, in animal studies, intravenous delivery of rhMG53 ameliorates cisplatin-induced AKI without affecting the tumor suppressor efficacy of cisplatin. These findings identify MG53 as a vital component of reno-protection, and targeting MG53-mediated repair of PTE cells represents a potential approach to prevention and treatment of AKI. PMID:25787762

  1. Active Piezoelectric Vibration Control of Subscale Composite Fan Blades

    NASA Technical Reports Server (NTRS)

    Duffy, Kirsten P.; Choi, Benjamin B.; Provenza, Andrew J.; Min, James B.; Kray, Nicholas

    2012-01-01

    As part of the Fundamental Aeronautics program, researchers at NASA Glenn Research Center (GRC) are investigating new technologies supporting the development of lighter, quieter, and more efficient fans for turbomachinery applications. High performance fan blades designed to achieve such goals will be subjected to higher levels of aerodynamic excitations which could lead to more serious and complex vibration problems. Piezoelectric materials have been proposed as a means of decreasing engine blade vibration either through a passive damping scheme, or as part of an active vibration control system. For polymer matrix fiber composite blades, the piezoelectric elements could be embedded within the blade material, protecting the brittle piezoceramic material from the airflow and from debris. To investigate this idea, spin testing was performed on two General Electric Aviation (GE) subscale composite fan blades in the NASA GRC Dynamic Spin Rig Facility. The first bending mode (1B) was targeted for vibration control. Because these subscale blades are very thin, the piezoelectric material was surface-mounted on the blades. Three thin piezoelectric patches were applied to each blade two actuator patches and one small sensor patch. These flexible macro-fiber-composite patches were placed in a location of high resonant strain for the 1B mode. The blades were tested up to 5000 rpm, with patches used as sensors, as excitation for the blade, and as part of open- and closed-loop vibration control. Results show that with a single actuator patch, active vibration control causes the damping ratio to increase from a baseline of 0.3% critical damping to about 1.0% damping at 0 RPM. As the rotor speed approaches 5000 RPM, the actively controlled blade damping ratio decreases to about 0.5% damping. This occurs primarily because of centrifugal blade stiffening, and can be observed by the decrease in the generalized electromechanical coupling with rotor speed.

  2. Membrane Vibration Tests Using Surface-Bonded Piezoelectric Patch Actuation

    NASA Technical Reports Server (NTRS)

    Gasper, James L.; Pappa, Richard S.

    2003-01-01

    This paper describes the status of on-going work at the NASA Langley Research Center to measure the dynamics of thin membranes. The test article is a one-meter square pre-tensioned Kapton membrane that incorporates small surface-bonded piezoelectric patches strategically positioned to excite many modes. It is shown that PVDF (polyvinylidene fluoride) and MFC (macro fiber composite) piezoelectric patch actuators provide adequate excitation energy to obtain modal frequencies and mode shapes. Results from modal tests performed on the membrane using piezoelectric patches of different sizes and positions are discussed.

  3. Self repairing composites for drone air vehicles

    NASA Astrophysics Data System (ADS)

    Dry, Carolyn

    2015-04-01

    The objective of this effort was to demonstrate the feasibility of impact-initiated delivery of repair chemicals through hollow fiber architectures embedded within graphite fiber reinforced polymer matrix composites, representative of advanced drone aircraft component material systems. Self-repairing structures through coupon and elements were demonstrated, and evaluated.

  4. Patch size and landscape effects on density and nesting success of grassland birds

    USGS Publications Warehouse

    Winter, Maiken; Johnson, Douglas H.; Shaffer, Jill A.; Donovan, Therese M.; Svedarsky, W. Daniel

    2006-01-01

    Current management recommendations for grassland birds in North America emphasize providing large patches of grassland habitat within landscapes that have few forest or shrubland areas. These Bird Conservation Areas are being proposed under the assumption that large patches of habitat in treeless landscapes will maintain viable populations of grassland birds. This assumption requires that patch size and landscape features affect density and nesting success of grassland birds, and that these effects are consistent among years and regions and across focal species. However, these assumptions have not yet been validated for grassland birds, and the relative importance of local vegetation structure, patch size, and landscape composition on grassland bird populations is not well known. In addition, factors influencing grassland bird nesting success have been investigated mostly in small-scale and short-duration studies. To develop management guidelines for grassland birds, we tested the spatial and temporal repeatability of the influence of patch size and landscape composition on density and nesting success of 3 grassland passerines, after controlling for local-scale vegetation structure, climate, and—when analyzing nest success—bird density. We conducted our study during 4 years (1998–2001) in 44 study plots that were set up in 3 regions of the northern tallgrass prairie in Minnesota and North Dakota, USA. In these study plots we measured density and nesting success of clay-colored sparrows (Spizella pallida), Savannah sparrows (Passerculus sandwichensis), and bobolinks (Dolichonyx oryzivorus). Statistical models indicated that density was influenced by patch size, landscape, region, and local vegetation structure more so than by local vegetation structure alone. Both magnitude and direction of the response of density to patch size varied among regions, years, and species. In contrast, the direction of landscape effects was consistent among regions, years, and between Savannah sparrows and bobolinks. In each species, this landscape effect was independent of patch size. Nesting success was not clearly influenced by patch size or landscape composition, and none of the factors that influenced avian density also influenced nesting success in any of the 3 species. General statements on “optimal habitat” for grassland birds should therefore be viewed cautiously. Instead, long-term studies in different regions as well as a deeper understanding of the local system are needed to determine which factors are most important for grassland birds in a particular area.

  5. Ceramic composite coating

    DOEpatents

    Wicks, George G.

    1997-01-01

    A thin, room-temperature-curing, ceramic composite for coating and patching etal substrates comprises a sol gel silica glass matrix filled with finely ground particles or fibers, preferably alumina. The sol gel glass is made by adding ethanol to water to form a first mixture, then separately adding ethanol to tetraethyl orthosilicate to form a second mixture, then slowly adding the first to the second mixture to make a third mixture, and making a slurry by adding the finely ground particles or fibers to the third mixture. The composite can be applied by spraying, brushing or trowelling. If applied to patch fine cracks, densification of the ceramic composite may be obtained to enhance sealing by applying heat during curing.

  6. Ceramic composite coating

    DOEpatents

    Wicks, G.G.

    1997-01-21

    A thin, room-temperature-curing, ceramic composite for coating and patching metal substrates comprises a sol gel silica glass matrix filled with finely ground particles or fibers, preferably alumina. The sol gel glass is made by adding ethanol to water to form a first mixture, then separately adding ethanol to tetraethyl orthosilicate to form a second mixture, then slowly adding the first to the second mixture to make a third mixture, and making a slurry by adding the finely ground particles or fibers to the third mixture. The composite can be applied by spraying, brushing or trowelling. If applied to patch fine cracks, densification of the ceramic composite may be obtained to enhance sealing by applying heat during curing.

  7. Ventral incisional hernia (VIH) repair after liver transplantation (OLT) with a biological mesh: experience in 3 cases.

    PubMed

    Schaffellner, S; Sereinigg, M; Wagner, D; Jakoby, E; Kniepeiss, D; Stiegler, P; Haybäck, J; Müller, H

    2016-05-01

    Hernias after orthotopic liver transplant (OLT) occur in about 30 % of cases. Predisposing factors in liver cirrhotic patients of cases are ascites, low abdominal muscle mass and cachexia before and immunosuppression after OLT. Standard operative transplant-technique even in small hernias is to implant a mesh. For patients after liver transplantation a porcine non-cross linked biological patch being less immunogenic than synthetic and cross-linked meshes is chosen for ventral incisional hernia repair. 3 patients (1 female, 2 male), OLT indications Hepatitis C, exogenous- toxic cirrhosis, median-age 53 (51 - 56) and median time to hernia occurrence after OLT were 10 month (6 - 18 m) are documented. 2 patients suffered from diabetes, 2 from chronic-obstructive lung disease. Maintenance immunosuppressions were Everolimus in 1 patient, Everolimus + MMF in the second and Everolimus +Tacrolimus in the third patient. The biological was chosen for hernia repair due to the preexisting risk- factors. Meshes, 10 × 16 cm were placed, in IPOM (Intra-Peritonel-Onlay-Mesh) -position by relaparatomy. Insolvable, monofile, interrupted sutures were used. All patients recovered primarily, and were dismissed within 10 d post OP. No wound healing disorders or signs of postoperative infections occurred. All are free of hernia recurrence in a mean observation time of 22 month (10 - 36). The usage of porcine non-cross-linked biological patches seems feasible for incisional hernia repair after OLT. Wound infections in these patients have been observed with other meshes. Further investigation is needed to prove potential superiority of this biological to the other meshes. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Early Results of Rheumatic Mitral Valve Repair.

    PubMed

    Petrone, Giuseppe; Theodoropoulos, Panagiotis; Punjabi, Prakash P

    2016-11-01

    Mitral valve repair (MVr) in rheumatic heart disease (RHD) remains challenging. The present authors' surgical experience of MVr in 56 patients with RHD operated in between January 2011 and September 2014 is reported. Among the patients (mean age 32 ± 11 years), 11 were in NYHA functional class II, 32 in class III, and seven in class IV. An adequate or oversized autologous pericardial patch was sutured to extend the coaptating edge of both the anterior leaflet (in 18 patients) and the posterior leaflet (in 30 patients). Neochordae were implanted as needed (n = 43), and leaflet thinning (n = 13), commissurotomy (n = 15) and chordal splitting (n = 9) were also performed. A rigid annuloplasty ring was implanted in 32 patients, and in 24 patients a complete flexible annuloplasty ring made from pericardium, 4 mm Gore-Tex tube graft or a Dacron patch was constructed. Repair was not attempted in 16 patients, with replacement using a mechanical bileaflet prosthesis being considered the only option. Intraoperative post-repair transesophageal echocardiography demonstrated competency, with trivial mitral regurgitation (MR) up to grade I in all patients and a minimum coaptation depth ≥5 mm. There were no intraoperative or in-hospital deaths. Clinical and echocardiographic evaluations were performed up to six weeks after surgery, at which time 51 patients were in NYHA classes I-II and five were in class III. Residual mild MR up to grade I was identified in six patients. No recurrence of MR was observed in any of the patients, and no patients were reoperated on. The lack of adequate access to anticoagulation medication and monitoring, in addition to religious/cultural bias to the type of prosthetic valve used in low-income countries, necessitates an increase in the numbers of rheumatic MVr.

  9. [Experimental study on loading naringin composite scaffolds for repairing rabbit osteochondral defects].

    PubMed

    Huang, Junbo; Wang, Shiyong; Zhang, Xiaomin; Li, Gen; Ji, Puzhong; Zhao, Hongbin

    2017-04-01

    To investigate the performance of loading naringin composite scaffolds and its effects on repair of osteochondral defects. The loading naringin and unloading naringin sustained release microspheres were prepared by W/O/W method; with the materials of the attpulgite and the collagen type I, the loading naringin, unloading naringin, and loading transforming growth factor β 1 (TGF-β 1 ) osteochondral composite scaffolds were constructed respectively by "3 layers sandwich method". The effect of sustained-release of loading naringin microspheres, the morphology of the composite scaffolds, and the biocompatibility were evaluated respectively by releasing in vitro , scanning electron microscope, and cell counting kit 8. Forty Japanese white rabbits were randomly divided into groups A, B, C, and D, 10 rabbits each group. After a osteochondral defect of 4.5 mm in diameter and 4 mm in depth was made in the intercondylar fossa of two femurs. Defect was not repaired in group A (blank control), and defect was repaired with unloading naringin composite scaffolds (negative control group), loading naringin composite scaffolds (experimental group), and loading TGF-β 1 composite scaffolds (positive control group) in groups B, C, and D respectively. At 3 and 6 months after repair, the intercondylar fossa was harvested for the general, HE staining, and toluidine blue staining to observe the repair effect. Western blot was used to detect the expression of collagen type II in the new cartilage. Loading naringin microspheres had good effect of sustained-release; the osteochondral composite scaffolds had good porosity; the cell proliferation rate on loading naringin composite scaffold was increased significantly when compared with unloading naringin scaffold ( P <0.05). General observation revealed that defect range of groups C and D was reduced significantly when compared with groups A and B at 3 months after repair; at 6 months after repair, defects of group C were covered by new cartilage, and new cartilage well integrated with the adjacent cartilage in group D. The results of histological staining revealed that defects were filled with a small amount of fibrous tissue in groups A and B, and a small amount of new cartilage in groups C and D at 3 months after repair; new cartilage of groups C and D was similar to normal cartilage, but defects were filled with a large amount of fibrous tissue in groups A and B at 6 months after repair. The expression of collagen type II in groups C and D was significantly higher than that in groups A and B ( P <0.05), but no significant difference was found between groups C and D ( P >0.05). Loading naringin composite scaffolds have good biocompatibility and effect in repair of rabbit articular osteochondral defects.

  10. Repair Strength in Simulated Restorations of Methacrylate- or Silorane-Based Composite Resins.

    PubMed

    Consani, Rafael Leonardo Xediek; Marinho, Tatiane; Bacchi, Atais; Caldas, Ricardo Armini; Feitosa, Victor Pinheiro; Pfeifer, Carmem Silvia

    2016-01-01

    The study verified the bond strength in simulated dental restorations of silorane- or methacrylate-based composites repaired with methacrylate-based composite. Methacrylate- (P60) or silorane-based (P90) composites were used associated with adhesive (Adper Single Bond 2). Twenty-four hemi-hourglass-shaped samples were repaired with each composite (n=12). Samples were divided according to groups: G1= P60 + Adper Single Bond 2+ P60; G2= P60 + Adper Single Bond 2 + P60 + thermocycling; G3= P90 + Adper Single Bond 2 + P60; and G4= P90 + Adper Single Bond 2 + P60 + thermocycling. G1 and G3 were submitted to tensile test 24 h after repair procedure, and G2 and G4 after submitted to 5,000 thermocycles at 5 and 55 ?#61616;C for 30 s in each bath. Tensile bond strength test was accomplished in an universal testing machine at crosshead speed of 0.5 mm/min. Data (MPa) were analyzed by two-way ANOVA and Tukey's test (5%). Sample failure pattern (adhesive, cohesive in resin or mixed) was evaluated by stereomicroscope at 30?#61655; and images were obtained in SEM. Bond strength values of methacrylate-based composite samples repaired with methacrylate-based composite (G1 and G2) were greater than for silorane-based samples (G3 and G4). Thermocycling decreased the bond strength values for both composites. All groups showed predominance of adhesive failures and no cohesive failure in composite resin was observed. In conclusion, higher bond strength values were observed in methacrylate-based resin samples and greater percentage of adhesive failures in silorane-based resin samples, both composites repaired with methacrylate-based resin.

  11. Repair of extrahepatic bile duct defect using a collagen patch in a Swine model.

    PubMed

    Tao, Liang; Li, Qiang; Ren, Haozhen; Chen, Bing; Hou, Xianglin; Mou, Lingjun; Zhou, Siqiao; Zhou, Jianxin; Sun, Xitai; Dai, Jianwu; Ding, Yitao

    2015-04-01

    Extrahepatic bile duct (EBD) injury can happen during surgery. To repair a defect of the EBD and prevent postoperative biliary complications, a collagen membrane was designed. The collagen material was porous, biocompatible, and degradable and could maintain its shape in bile soaking for about 4 weeks. The goal was to induce rapid bile duct tissue regeneration. Twenty Chinese experimental hybrid pigs were used in this study and divided into a patch group and a control group. A spindle-shaped defect (20 mm × 6 mm) was made in the anterior wall of the lower EBD in the swine model, and then the defect was reconstructed using a collagen patch with a drainage tube and wrapped with greater omentum. Ultrasound was performed at 2, 4, 8, and 12 weeks postoperatively. Liver function tests and white blood cell count (WBC) were measured. Hematoxylin-eosin staining, cytokeratin 7 immunohistochemical staining, and Van Gieson's staining of EBD were used. The diameter and thickness of the EBD at the graft site were measured. There was no significant difference in liver function tests or WBC in the patch group compared with the control group. No evidence of leakage or stricture was observed, but some pigs developed biliary sludge or stone at 4 and 8 weeks. The drainage tube was lost within 12 weeks. The neo-EBD could withstand normal biliary pressure 2 weeks after surgery. Histological study showed the accessory glands and epithelial cells gradually regenerated at graft sites from 4 weeks, with increasing vessel infiltration and decreasing inflammation. The collagen fibers became regular with full coverage of epithelial cells. The statistical analysis of diameter and thickness showed no stricture formation at the graft site, but the EBD wall was slightly thicker than in the normal bile duct due to collagen fiber deposition. The structure of the neo-EBD was similar to that of the normal EBD. The collagen membrane patch associated with a drainage tube and wrapped with greater omentum effectively induced the regeneration of the EBD defect within 12 weeks. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Effects of the duration and inorganic nitrogen composition of a nutrient-rich patch on soil exploration by the roots of Lolium perenne in a heterogeneous environment.

    PubMed

    Nakamura, Ryoji; Kachi, N; Suzuki, J-I

    2010-05-01

    We investigated the growth of and soil exploration by Lolium perenne under a heterogeneous environment before its roots reached a nutrient-rich patch. Temporal changes in the distribution of inorganic nitrogen, i.e., NO(3)(-)-N and NH(4)(+)-N, in the heterogeneous environment during the experimental period were also examined. The results showed that roots randomly explored soil, irrespective of the patchy distribution of inorganic nitrogen and differences in the chemical composition of inorganic nitrogen distribution between heterogeneous and homogeneous environments. We have also elucidated the potential effects of patch duration and inorganic nitrogen distribution on soil exploration by roots and thus on plant growth.

  13. Covalent modification of pericardial patches for sustained rapamycin delivery inhibits venous neointimal hyperplasia

    PubMed Central

    Bai, Hualong; Lee, Jung Seok; Chen, Elizabeth; Wang, Mo; Xing, Ying; Fahmy, Tarek M.; Dardik, Alan

    2017-01-01

    Prosthetic grafts and patches are commonly used in cardiovascular surgery, however neointimal hyperplasia remains a significant concern, especially under low flow conditions. We hypothesized that delivery of rapamycin from nanoparticles (NP) covalently attached to patches allows sustained site-specific delivery of therapeutic agents targeted to inhibit localized neointimal hyperplasia. NP were covalently linked to pericardial patches using EDC/NHS chemistry and could deliver at least 360 ng rapamycin per patch without detectable rapamycin in serum; nanoparticles were detectable in the liver, kidney and spleen but no other sites within 24 hours. In a rat venous patch angioplasty model, control patches developed robust neointimal hyperplasia on the patch luminal surface characterized by Eph-B4-positive endothelium and underlying SMC and infiltrating cells such as macrophages and leukocytes. Patches delivering rapamycin developed less neointimal hyperplasia, less smooth muscle cell proliferation, and had fewer infiltrating cells but retained endothelialization. NP covalently linked to pericardial patches are a novel composite delivery system that allows sustained site-specific delivery of therapeutics; NP delivering rapamycin inhibit patch neointimal hyperplasia. NP linked to patches may represent a next generation of tissue engineered cardiovascular implants. PMID:28071663

  14. Covalent modification of pericardial patches for sustained rapamycin delivery inhibits venous neointimal hyperplasia

    NASA Astrophysics Data System (ADS)

    Bai, Hualong; Lee, Jung Seok; Chen, Elizabeth; Wang, Mo; Xing, Ying; Fahmy, Tarek M.; Dardik, Alan

    2017-01-01

    Prosthetic grafts and patches are commonly used in cardiovascular surgery, however neointimal hyperplasia remains a significant concern, especially under low flow conditions. We hypothesized that delivery of rapamycin from nanoparticles (NP) covalently attached to patches allows sustained site-specific delivery of therapeutic agents targeted to inhibit localized neointimal hyperplasia. NP were covalently linked to pericardial patches using EDC/NHS chemistry and could deliver at least 360 ng rapamycin per patch without detectable rapamycin in serum; nanoparticles were detectable in the liver, kidney and spleen but no other sites within 24 hours. In a rat venous patch angioplasty model, control patches developed robust neointimal hyperplasia on the patch luminal surface characterized by Eph-B4-positive endothelium and underlying SMC and infiltrating cells such as macrophages and leukocytes. Patches delivering rapamycin developed less neointimal hyperplasia, less smooth muscle cell proliferation, and had fewer infiltrating cells but retained endothelialization. NP covalently linked to pericardial patches are a novel composite delivery system that allows sustained site-specific delivery of therapeutics; NP delivering rapamycin inhibit patch neointimal hyperplasia. NP linked to patches may represent a next generation of tissue engineered cardiovascular implants.

  15. Geometrically nonlinear transient vibrations of actively damped anti-symmetric angle ply laminated composite shallow shell using active fibre composite (AFC) actuators

    NASA Astrophysics Data System (ADS)

    Ashok, M. H.; Shivakumar, J.; Nandurkar, Santosh; Khadakbhavi, Vishwanath; Pujari, Sanjay

    2018-02-01

    In present work, the thin laminated composite shallow shell as smart structure with AFC material’s ACLD treatment is analyzed for geometrically nonlinear transient vibrations. The AFC material is used to make the constraining layer of the ACLD treatment. Golla-Hughes-McTavish (GHM) is used to model the constrained viscoelastic layer of the ACLD treatment in time domain. Along with a simple first-order shear deformation theory the Von Kármán type non-linear strain displacement relations are used for deriving this electromechanical coupled problem. A 3-dimensional finite element model of smart composite panels integrated with the ACLD treated patches has been modelled to reveal the performance of ACLD treated patches on improving the damping properties of slender anti-symmetric angle-ply laminated shallow shell, in controlling the transient vibrations which are geometrically nonlinear. The mathematical results explain that the ACLD treated patches considerably enhance the damping properties of anti-symmetric angle-ply panels undergoing geometrically nonlinear transient vibrations.

  16. Certification Tests on Cold Patch Asphalt Repair Materials for Use in Airfield Pavements

    DTIC Science & Technology

    2010-06-01

    in Airfield Pavements Mariely Mejías-Santiago, Franciso del Valle Roldán, and Lucy P. Priddy Geotechnical and Structures Laboratory U.S. Army...28 Figure 19. Pavement structure in the test section...ERDC), Geotechnical and Structures Laboratory (GSL), Vicksburg, MS. The findings and recommendations presented in this report are based upon laboratory

  17. Concrete Finisher: Apprenticeship Course Outline. Apprenticeship and Industry Training. 4805.2

    ERIC Educational Resources Information Center

    Alberta Advanced Education, 2005

    2005-01-01

    The graduate of the Concrete Finisher apprenticeship program is a certified journeyperson who will be able to: (1) perform tests to confirm concrete quality; (2) interpret building codes, plans and specifications as they apply to the trade; (3) place and finish concrete in a professional manner; (4) cut, patch, maintain and repair concrete…

  18. Amplification of unscheduled DNA synthesis signal enables fluorescence-based single cell quantification of transcription-coupled nucleotide excision repair

    PubMed Central

    Wienholz, Franziska; Vermeulen, Wim

    2017-01-01

    Abstract Nucleotide excision repair (NER) comprises two damage recognition pathways: global genome NER (GG-NER) and transcription-coupled NER (TC-NER), which remove a wide variety of helix-distorting lesions including UV-induced damage. During NER, a short stretch of single-stranded DNA containing damage is excised and the resulting gap is filled by DNA synthesis in a process called unscheduled DNA synthesis (UDS). UDS is measured by quantifying the incorporation of nucleotide analogues into repair patches to provide a measure of NER activity. However, this assay is unable to quantitatively determine TC-NER activity due to the low contribution of TC-NER to the overall NER activity. Therefore, we developed a user-friendly, fluorescence-based single-cell assay to measure TC-NER activity. We combined the UDS assay with tyramide-based signal amplification to greatly increase the UDS signal, thereby allowing UDS to be quantified at low UV doses, as well as DNA-repair synthesis of other excision-based repair mechanisms such as base excision repair and mismatch repair. Importantly, we demonstrated that the amplified UDS is sufficiently sensitive to quantify TC-NER-derived repair synthesis in GG-NER-deficient cells. This assay is important as a diagnostic tool for NER-related disorders and as a research tool for obtaining new insights into the mechanism and regulation of excision repair. PMID:28088761

  19. Generic patches containing fentanyl: In vitro equivalence and abuse deterrent evaluation according to EMA and FDA guidelines.

    PubMed

    Padula, Cristina; Pescina, Silvia; Nicoli, Sara; Santi, Patrizia

    2018-02-15

    The aim of this work was to characterize in vitro and ex vivo the performances of Durogesic and of two bioequivalent generic products, by evaluating: (a) fentanyl release; (b) fentanyl permeation across porcine skin and (c) fentanyl ease of extraction. Additional characteristics studied are the effect of temperature and skin integrity, applied individually or combined, to check a possible synergism. The two generic patches resulted equivalent to the originator according to the new Guideline. Nevertheless, the same data reported in a different way, i.e. considering the total amount of drug permeated from the whole patch over the application time, highlight differences among the patches. The additional tests performed showed that skin integrity does not represent a barrier for fentanyl permeation across the skin, regardless of the type and complexity of the patch. The effect of temperature resulted critical for two out of three patches, probably due to the different composition and to the different structure. The combination of skin damage and elevated temperature did not produce a synergistic effect. Fentanyl extraction was different for the different products and variable according to the conditions used. The results reported in the present work underline the influence of patch composition and complexity on fentanyl extraction, release and skin permeation, in particular in conditions that can be critical, such as elevated temperature. In particular, the effect of critical variables, such as skin integrity and temperature, should be addressed to in the development of a new or new generic patch and new discriminant tests should be developed. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. [Effect of thermal cycling on the composite- composite repair bond strength].

    PubMed

    Liu, Chang; Lin, Fei; Yue, Lin

    2015-08-01

    To evaluate the effect of aging of the composite and the adhesive interface on composite-composite repair bond strength. Methacrylate-based composite resin (Clearfil AP-X, composite A) and silorane-based composite resin (Filtek P90, composite B) and their corresponding adhesive, Clearfil SE Bond (adhesive a) and Filtek P90 System Adhesive (adhesive b), were selected in this study. Twenty-four substrates were prepared from composite A or B separately and divided into three groups, each group had 8 substrates: group one, new composites were adhered to the substrates with the use of adhesive a or b, followed by cutting the blocks into sticks; group two, new composites were adhered to the substrates using adhesive a or b, followed by cutting into sticks and thermal cycling; group three, substrates were thermocycled, then polished and adhered new composites using adhesive a or b, followed by cutting into sticks. Each group had 8 combinations of substrate(A, B)-adhesive(a, b)-repair composite (A, B). Fifteen sticks without flaws in each combination of 3 groups were selected utilizing stereomicroscope. The data were analyzed by independent samples t test. In group two, the microtensile strength(MS) of combinations using adhesive a and composite A or B to repair [A-a-A: (45.0 ± 3.2) MPa, B-a-A: (41.7 ± 3.3) MPa, A-a-B: (28.6 ± 3.9) MPa, B-a-B: (47.7 ± 6.6) MPa], and using adhesive b and composite A to repair [A-b-A: (44.2 ± 4.7) MPa, B-b-A: (38.0 ± 3.2) MPa] decreased significantly compared with corresponding combinations in group 1[A-a-A: (70.7 ± 5.5) MPa, B-a-A: (60.3 ± 5.1) MPa, A-a-B: (44.2 ± 1.6) MPa, B-a-B: (54.1 ± 3.2) MPa, A-b-A: (65.6 ± 7.2) MPa, B-b-A: (59.1 ± 4.1) MPa] (P<0.05). However, there was no significant difference between the MS of combinations using adhesive b and composite B to repair in group one and the MS of combinations in group two (P>0.05). The MS of all combinations in group three decreased significantly (P<0.05). Aging of the composite and the adhesive interface might affect the composite-composite repair bond strength.

  1. Contact allergy to denture materials in the burning mouth syndrome.

    PubMed

    van Joost, T; van Ulsen, J; van Loon, L A

    1988-02-01

    Several factors may be responsible for stomatitis in general and the burning mouth syndrome in particular. The results of patch testing are reported in 4 patients with burning mouth symptoms thought to be due to sensitization to denture material. 2 patients reacted to substances in Luxene dentures, but the allergens were not identified. In a 3rd patient, sensitization was found to monomeric methyl methacrylate. The other patient gave positive patch tests to epoxy resin (and bisphenol A), probably present in glue used for repair of dental plates. To obtain a complete diagnosis in cases of suspected contact stomatitis due to allergens in dentures, a reliable standard test series is required.

  2. Repair bond strength in aged methacrylate- and silorane-based composites.

    PubMed

    Bacchi, Atais; Consani, Rafael Leonardo; Sinhoreti, Mario Alexandre; Feitosa, Victor Pinheiro; Cavalcante, Larissa Maria; Pfeifer, Carmem Silva; Schneider, Luis Felipe

    2013-10-01

    To evaluate the tensile bond strength at repaired interfaces of aged dental composites, either dimethacrylate- or silorane-based, when subjected to different surface treatments. The composites used were Filtek P60 (methacrylate-based, 3M ESPE) and Filtek P90 (silorane-based, 3M ESPE), of which 50 slabs were stored for 6 months at 37°C. The surface of adhesion was abraded with a 600-grit silicone paper and the slabs repaired with the respective composite, according to the following surface treatment protocols: G1: no treatment; G2: adhesive application; G3: silane + adhesive; G4: sandblasting (Al2O3) + adhesive; G5: sandblasting (Al2O3) + silane + adhesive. After 24-h storage in distilled water at 37°C, tensile bond strength (TBS) was determined in a universal testing machine (Instron 4411) at a crosshead speed of 0.5 mm/min. The original data were submitted to two-way ANOVA and Tukey's test (α = 5%). The methacrylate-based composite presented a statistically significantly higher repair potential than did the silorane-based resin (p = 0.0002). Of the surface treatments for the silorane-based composite, aluminum-oxide air abrasion and adhesive (18.5 ± 3.3MPa) provided higher bond strength than only adhesive application or the control group without surface treatment. For Filtek P60, the control without treatment presented lower repair strength than all other groups with surface treatments, which were statistically similar to each other. The interaction between the factors resin composite and surface treatment was significant (p = 0.002). For aged silorane-based materials, repairs were considered successful after sandblasting (Al2O3) and adhesive application. For methacrylate resin, repair was successful with all surface treatments tested.

  3. Sealing of minimally invasive Class II fillings (slot) using an adhesive patch: sealant margin extension for prevention.

    PubMed

    Schmidlin, Patrick R; Seemann, Rainer; Filli, Tilla; Attin, Thomas; Imfeld, Thomas

    2007-01-01

    A laboratory study was performed to assess the potential of an adhesive patch to seal small, unbeveled, Class II, box-only (slot) composite fillings. After minimal access cavity preparation with an 80 pm diamond bur, 40 box-only Class II cavities were prepared mesially and distally in 20 extracted human molars using a u-shaped PCS insert (EMS). One cavity per tooth was adhesively filled with a hybrid composite material in one increment. A patch, acting as an adhesive matrice, was applied to the other cavity of each tooth to seal the restoration. The margin of the patch was located in areas easily accessible to oral hygiene measures and self-cleaning. All the teeth were subjected to thermo-mechanical stress in a computer-controlled masticator device. In 10 teeth, caries was induced in a microbial-based artificial mouth model and quantitatively determined by confocal laser scanning microscopy. Microleakage was assessed in the other 10 teeth in two planar sections after immersion in 0.5% basic fuchsin solution. The results showed no demineralization at the filling margins protected with the patch. Microleakage was observed in one sample only and was limited to the enamel. In contrast, the margins of fillings without the patch application showed a mean demineralization depth of 146 +/- 42 microm and dye penetration into the dentin in five sections. This innovative approach to sealing restorative margins with an adhesive patch results in less leakage and filling margin demineralization and merits further investigation.

  4. Laparoscopic inguinal hernia repair: gold standard in bilateral hernia repair? Results of more than 2800 patients in comparison to literature.

    PubMed

    Wauschkuhn, Constantin Aurel; Schwarz, Jochen; Boekeler, Ulf; Bittner, Reinhard

    2010-12-01

    Advantages and disadvantages of open and endoscopic hernia surgery are still being discussed. Until now there has been no study that evaluated the advantages and disadvantages of bilateral hernia repair in a large number of patients. Our prospectively collected database was analyzed to compare the results of laparoscopic bilateral with laparoscopic unilateral hernia repair. We then compared these results with the results of a literature review regarding open and laparoscopic bilateral hernia repair. From April 1993 to December 2007 there were 7240 patients with unilateral primary hernia (PH) and 2880 patients with bilateral hernia (5760 hernias) who underwent laparoscopic transabdominal preperitoneal patch plastic (TAPP). Of the 10,120 patients, 28.5% had bilateral hernias. Adjusted for the number of patients operated on, the mean duration of surgery for unilateral hernia repair was shorter than that for bilateral repair (45 vs. 70 min), but period of disability (14 vs. 14 days) was the same. Adjusted for the number of hernias repaired, morbidity (1.9 vs. 1.4%), reoperation (0.5 vs. 0.43%), and recurrence rate (0.63 vs. 0.42%) were similar for unilateral versus bilateral repair, respectively. The review of the literature shows a significantly shorter time out of work after laparoscopic bilateral repair than after the bilateral open approach. Simultaneous laparoscopic repair of bilateral inguinal hernias does not increase the risk for the patient and has an equal length of down time compared with unilateral repair. According to literature, recovery after laparoscopic repair is faster than after open simultaneous repair. Laparoscopic/endoscopic inguinal hernia repair of bilateral hernias should be recommended as the gold standard.

  5. Two sides of the same coin: TFIIH complexes in transcription and DNA repair.

    PubMed

    Zhovmer, Alexander; Oksenych, Valentyn; Coin, Frédéric

    2010-04-13

    TFIIH is organized into a seven-subunit core associated with a three-subunit Cdk-activating kinase (CAK) module. TFIIH has roles in both transcription initiation and DNA repair. During the last 15 years, several studies have been conducted to identify the composition of the TFIIH complex involved in DNA repair. Recently, a new technique combining chromatin immunoprecipitation and western blotting resolved the hidden nature of the TFIIH complex participating in DNA repair. Following the recruitment of TFIIH to the damaged site, the CAK module is released from the core TFIIH, and the core subsequently associates with DNA repair factors. The release of the CAK is specifically driven by the recruitment of the DNA repair factor XPA and is required to promote the incision/excision of the damaged DNA. Once the DNA lesions have been repaired, the CAK module returns to the core TFIIH on the chromatin, together with the release of the repair factors. These data highlight the dynamic composition of a fundamental cellular factor that adapts its subunit composition to the cell needs.

  6. Species presence frequency and diversity in different patch types along an altitudinal gradient: Larix chinensis Beissn in Qinling Mountains (China).

    PubMed

    Huang, Minyi; Duan, Renyan; Wang, Shixiong; Wang, Zhigao; Fan, Weiyi

    2016-01-01

    Forest communities are mosaic systems composed of patches classified into four different developmental patch types: gap patch (G), building patch (B), mature patch (M) and degenerate patch (D). To study the mechanisms maintaining diversity in subalpine coniferous forests, species presence frequency and diversity in the four distinct patch types (G, B, M and D) of Larix chinensis conifer forests at three altitudinal gradients in the Qinling Mountains were analyzed. Our results were as follows: (1) Different species (or functional groups) had distinct presence frequencies in the four different patch types along the altitudinal gradient; (2) Some species or functional groups (species groups sharing similar traits and responses to the environment) only occurred in some specific patches. For seed dispersal, species using wind mainly occurred in G and D, while species using small animals mainly occurred in B and M; (3) Species composition of adjacent patch types was more similar than non-adjacent patch types, based on the lower β diversity index of the former; (4) The maximum numbers of species and two diversity indices (D' and H') were found in the middle altitudes. Various gap-forming processes and dispersal limitation may be the two major mechanisms determining species diversity in Larix chinensis coniferous forests at the patch scale.

  7. Nanowired three-dimensional cardiac patches

    NASA Astrophysics Data System (ADS)

    Dvir, Tal; Timko, Brian P.; Brigham, Mark D.; Naik, Shreesh R.; Karajanagi, Sandeep S.; Levy, Oren; Jin, Hongwei; Parker, Kevin K.; Langer, Robert; Kohane, Daniel S.

    2011-11-01

    Engineered cardiac patches for treating damaged heart tissues after a heart attack are normally produced by seeding heart cells within three-dimensional porous biomaterial scaffolds. These biomaterials, which are usually made of either biological polymers such as alginate or synthetic polymers such as poly(lactic acid) (PLA), help cells organize into functioning tissues, but poor conductivity of these materials limits the ability of the patch to contract strongly as a unit. Here, we show that incorporating gold nanowires within alginate scaffolds can bridge the electrically resistant pore walls of alginate and improve electrical communication between adjacent cardiac cells. Tissues grown on these composite matrices were thicker and better aligned than those grown on pristine alginate and when electrically stimulated, the cells in these tissues contracted synchronously. Furthermore, higher levels of the proteins involved in muscle contraction and electrical coupling are detected in the composite matrices. It is expected that the integration of conducting nanowires within three-dimensional scaffolds may improve the therapeutic value of current cardiac patches.

  8. [Subchondral drilling method combined with gum-bletilla complex to repair articular cartilage defects].

    PubMed

    Huang, Yong; Wang, Xin-Ling; Qiu, Heng; Xiao, Yi-Cheng; Wu, Zong-Hong; Xu, Jian

    2018-02-01

    Two types(A model and B model) of articular cartilage defect models were prepared by using adult New Zealand white rabbits. A model group was applied by drilling without through subchondral bone, whose right joint was repaired by composite scaffolds made by seed cell, gum-bletilla as well as Pluronic F-127, and left side was blank control. B model group was applied by subchondral drilling method, whose right joint was repaired by using composite scaffolds made by gum-bletilla and Pluronic F-127 without seed cells, and left side was blank control. Autogenous contrast was used in both model types. In addition, another group was applied with B model type rabbits, which was repaired with artificial complex material of Pluronic F-127 in both joint sides. 4, 12 and 24 weeks after operation, the animals were sacrificed and the samples were collected from repaired area for staining with HE, typeⅡcollagen immunohistochemical method, Alcian blue, and toluidine blue, and then were observed with optical microscope. Semi-quantitative scores were graded by referring to Wakitanis histological scoring standard to investigate the histomorphology of repaired tissue. Hyaline cartilage repairing was achieved in both Group A and Group B, with satisfactory results. There were no significant differences on repairing effects for articular cartilage defects between composite scaffolds made by seed cell, gum-bletilla and Pluronic F-127, and the composite scaffolds made by gum-bletilla and Pluronic F-127 without seed cell. Better repairing effects for articular cartilage defects were observed in groups with use of gum-bletilla, indicating that gum-bletilla is a vital part in composite scaffolds material. Copyright© by the Chinese Pharmaceutical Association.

  9. Invertebrate community response to a shifting mosaic of habitat

    USGS Publications Warehouse

    Engle, David M.; Fuhlendorf, S.D.; Roper, A.; Leslie, David M.

    2008-01-01

    Grazing management has focused largely on promoting vegetation homogeneity through uniform distribution of grazing to minimize area in a pasture that is either heavily disturbed or undisturbed. An alternative management model that couples grazing and fire (i.e., patch burning) to promote heterogeneity argues that grazing and fire interact through a series of positive and negative feedbacks to cause a shifting mosaic of vegetation composition and structure across the landscape. We compared patch burning with traditional homogeneity-based management in tallgrass prairie to determine the influence of the two treatments on the aboveground invertebrate community. Patch burning resulted in a temporal flush of invertebrate biomass in patches transitional between unburned and patches burned in the current year. Total invertebrate mass was about 50% greater in these transitional patches within patch-burned pastures as compared to pastures under traditional, homogeneity-based management. Moreover, the mosaic of patches in patch-burned pastures contained a wider range of invertebrate biomass and greater abundance of some invertebrate orders than did the traditionally managed pastures. Patch burning provides habitat that meets requirements for a broad range of invertebrate species, suggesting the potential for patch burning to benefit other native animal assemblages in the food chain.

  10. Endoscope-assisted laparoscopic repair of perforated peptic ulcers.

    PubMed

    Lee, Kun-Hua; Chang, Hung-Chi; Lo, Chong-Jeh

    2004-04-01

    Laparoscopic repairs for perforated peptic ulcer (PPU) are likely to fail in patients with shock, gastric outlet obstruction, or large perforations. This prospective study was performed to evaluate a revised approach of laparoscopic repair with endoscopic assistance to treat these patients. Between April 2001 and February 2002, 30 consecutive patients with PPU were enrolled in this study. The mean age was 43.1 +/- 12.2 years. Male to female ratio was 27:2. One patient was excluded from laparoscopic repair due to a gastric outlet obstruction. The other 29 patients were managed according to a protocol of preoperative upper endoscopy and laparoscopic intracorporeal suture repair with an omental patch. The average operative time was 58.1 +/- 13.5 minutes (range, 36-96 min). The average diameter of perforation was 4.2 +/- 2.0 mm (range, 1-12 mm). The average time to resume oral fluids was 3.2 +/- 0.8 days (range, 2-8 days). The average hospital stay was 4.7 +/- 1.1 days (range, 3-10 days). There was no leakage or mortality. Most patients did not receive parenteral analgesics postoperatively. We conclude that endoscope-assisted laparoscopic repair for PPU is safe and effective. This revised technique allows surgeons to exclude patients who are likely to fail the laparoscopic repair.

  11. Self-repairing composites for airplane components

    NASA Astrophysics Data System (ADS)

    Dry, Carolyn

    2008-03-01

    Durability and damage tolerance criteria drives the design of most composite structures. Those criteria could be altered by developing structure that repairs itself from impact damage. This is a technology for increasing damage tolerance for impact damage. Repaired damage would enable continued function and prevent further degradation to catastrophic failure in the case of an aircraft application. Further, repaired damage would enable applications to be utilized without reduction in performance due to impacts. Self repairing structures are designed to incorporate hollow fibers, which will release a repairing agent when the structure is impacted, so that the repairing agent will fill delaminations, voids and cracks in les than one minute, thus healing matrix voids. The intent is to modify the durability and damage tolerance criteria by incorporation of self-healing technologies to reduce overall weight: The structure will actually remain lighter than current conventional design procedures allow. Research objective(s) were: Prove that damage can be repaired to within 80-90% of original flexural strength in less than one minute, in laminates that are processed at 300-350F typical for aircraft composites. These were successfully met. The main focus was on testing of elements in compression after impact and a larger component in shear at Natural Process Design, Inc. Based on these results the advantages purposes are assessed. The results show potential; with self repairing composites, compressive strength is maintained sufficiently so that less material can be used as per durability and damage tolerance, yielding a lighter structure.

  12. Experimental Spin Testing of Integrally Damped Composite Plates

    NASA Technical Reports Server (NTRS)

    Kosmatka, John

    1998-01-01

    The experimental behavior of spinning laminated composite pretwisted plates (turbo-fan blade-like) with small (less than 10% by volume) integral viscoelastic damping patches was investigated at NASA-Lewis Research Center. Ten different plate sets were experimentally spin tested and the resulting data was analyzed. The first-four plate sets investigated tailoring patch locations and definitions to damp specific modes on spinning flat graphite/epoxy plates as a function of rotational speed. The remaining six plate sets investigated damping patch size and location on specific modes of pretwisted (30 degrees) graphite/epoxy plates. The results reveal that: (1) significant amount of damping can be added using a small amount of damping material, (2) the damped plates experienced no failures up to the tested 28,000 g's and 750,000 cycles, (3) centrifugal loads caused an increase in bending frequencies and corresponding reductions in bending damping levels that are proportional to the bending stiffness increase, and (4) the centrifugal loads caused a decrease in torsion natural frequency and increase in damping levels of pretwisted composite plates.

  13. Resin composite repair for implant-supported crowns.

    PubMed

    Bonfante, Estevam A; Suzuki, Marcelo; Hirata, Ronaldo; Bonfante, Gerson; Fardin, Vinicius P; Coelho, Paulo G

    2017-08-01

    This study evaluated the reliability of implant-supported crowns repaired with resin composites. Fifty-four titanium abutments were divided in three groups (n = 18 each) to support resin nanoceramic molar crowns, as follows: (LU) (Lava Ultimate, 3M ESPE); LU repaired with either a direct or an indirect resin composite. Samples were subjected to mouth-motion accelerated-life testing in water (n = 18). Cumulative damage with a use stress of 300 N was used to plot Weibull curves for group comparison. Reliability was calculated for a mission of 100,000 cycles at 400 N load. Beta values were 0.83 for LU, 0.31 and 0.27 for LU repaired with Filtek and Ceramage, respectively. Weibull modulus for LU was 9.5 and η = 1047 N, m = 6.85, and η = 1002 N for LU repaired with Ceramage, and m = 4.65 and η = 766 N for LU repaired with Filtek (p < 0.10 between LU and LU repaired with Filtek). Reliability at 400 N was 100% for both LU and LU repaired with Ceramage which were significantly higher than LU Filtek repair (32%). LU restored crowns failed cohesively. Fractures were confined within the restored material, and detailed fractography is presented. The performance of resin nanoceramic material repaired with an indirect composite was maintained after accelerated-life testing compared to unrepaired controls. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1481-1489, 2017. © 2016 Wiley Periodicals, Inc.

  14. Effect of Different Surface Treatments on Repair Micro-shear Bond Strength of Silica- and Zirconia-filled Composite Resins

    PubMed Central

    Joulaei, Mohammad; Bahari, Mahmoud; Ahmadi, Anahid; Savadi Oskoee, Siavash

    2012-01-01

    Background and aims Effect of surface treatments on repair bond strength of aged composite resins might be different due to their dissimilar fillers. The aim was to evaluate the effect of different surface treatments on repair micro-shear bond strength (µSBS) of silica- (Spectrum TPH) and zirconia-filled (Filtek Z250) composite resins. Materials and methods Twenty-seven composite resin blocks were made from each type of composite resin: Z250 and Spectrum TPH. After aging, blocks of each type were randomly divided into three groups according to surface treatments: alloy primer, silane, and only surface roughening. Subsequently, each group was further subdivided into 3 subgroups based on the adhesive system used: Single Bond, Clearfil SE Bond, and Margin Bond. Four composite resin columns were added on each block. After thermocycling, µSBStest were done at cross head speed of 0.5 mm/min. Data was analysed using multifactor ANOVA, one-way ANOVA and a post-hoc Bonferroni tests (α = 0.05). Results Analysis of data showed that the effect of composite resin type was not significant (p > 0.05), but the effects of the type of surface treatment (p = 0.01) and the type of adhesive system (p = 0.01) were significant on repair µSBS. In addition, the cumulative effect of the composite type-surface treatment and the composite type with the type of adhesive system were not statistically significant (p > 0.05). However, the cumulative effects of the adhesive system-surface treatment (p = 0.03) and the composite type-the adhesive system-surface treatments (p = 0.002) were significant. Conclusion Although repair µSBS values of both silica- and zirconia-filled composite resins were similar, use of different combinations of surface treatments and adhesive systems affected their repair µSBS differently. PMID:23277859

  15. Species sorting and patch dynamics in harlequin metacommunities affect the relative importance of environment and space.

    PubMed

    Leibold, Mathew A; Loeuille, Nicolas

    2015-12-01

    Metacommunity theory indicates that variation in local community structure can be partitioned into components including those related to local environmental conditions vs. spatial effects and that these can be quantified using statistical methods based on variation partitioning. It has been hypothesized that joint associations of community composition with environment and space could be due to patch dynamics involving colonization-extinction processes in environmentally heterogeneous landscapes but this has yet to be theoretically shown. We develop a two-patch, type-two, species competition model in such a "harlequin" landscape (where different patches have different environments) to evaluate how composition is related to environmental and spatial effects as a function of background extinction rate. Using spatially implicit analytical models, we find that the environmental association of community composition declines with extinction rate as expected. Using spatially explicit simulation models, we further find that there is an increase in the spatial structure with extinction due to spatial patterning into clusters that are not related to environmental conditions but that this increase is limited. Natural metacommunities often show both environment and spatial determination even under conditions of relatively high isolation and these could be more easily explained by our model than alternative metacommunity models.

  16. VRPI Thermoresponsive Reversibly Attachable Patch for Temporary Intervention in Ocular Trauma

    DTIC Science & Technology

    2014-09-01

    Polymerization (ATRP) on biocompatible substrates (e.g. parylene, polyimide , etc.). Adhesion data performed on preliminary samples under uniaxial testing...adhesion performance is completed in vitro, adhesion in vivo and biocompatibility will be assessed using a rabbit animal model. 15. SUBJECT TERMS...vitro, validate adhesive performance in vivo and perform preliminary biocompatibility assessments. 2. Keywords. sutureless wound repair

  17. Preconditioning allows engraftment of mouse and human embryonic lung cells, enabling lung repair in mice.

    PubMed

    Rosen, Chava; Shezen, Elias; Aronovich, Anna; Klionsky, Yael Zlotnikov; Yaakov, Yasmin; Assayag, Miri; Biton, Inbal Eti; Tal, Orna; Shakhar, Guy; Ben-Hur, Herzel; Shneider, David; Vaknin, Zvi; Sadan, Oscar; Evron, Shmuel; Freud, Enrique; Shoseyov, David; Wilschanski, Michael; Berkman, Neville; Fibbe, Willem E; Hagin, David; Hillel-Karniel, Carmit; Krentsis, Irit Milman; Bachar-Lustig, Esther; Reisner, Yair

    2015-08-01

    Repair of injured lungs represents a longstanding therapeutic challenge. We show that human and mouse embryonic lung tissue from the canalicular stage of development (20-22 weeks of gestation for humans, and embryonic day 15-16 (E15-E16) for mouse) are enriched with progenitors residing in distinct niches. On the basis of the marked analogy to progenitor niches in bone marrow (BM), we attempted strategies similar to BM transplantation, employing sublethal radiation to vacate lung progenitor niches and to reduce stem cell competition. Intravenous infusion of a single cell suspension of canalicular lung tissue from GFP-marked mice or human fetal donors into naphthalene-injured and irradiated syngeneic or SCID mice, respectively, induced marked long-term lung chimerism. Donor type structures or 'patches' contained epithelial, mesenchymal and endothelial cells. Transplantation of differentially labeled E16 mouse lung cells indicated that these patches were probably of clonal origin from the donor. Recipients of the single cell suspension transplant exhibited marked improvement in lung compliance and tissue damping reflecting the energy dissipation in the lung tissues. Our study provides proof of concept for lung reconstitution by canalicular-stage human lung cells after preconditioning of the pulmonary niche.

  18. Bioactive glass/polymer composites for bone and nerve repair and regeneration

    NASA Astrophysics Data System (ADS)

    Mohammadkhah, Ali

    Bioactive glasses have several attractive properties in hard and soft tissue repair but their brittleness limited their use, as scaffolding materials, for applications in load-bearing hard tissue repair. At the same time, because of their bioactive properties, they are being studied more often for soft tissue repair. In the present work, a new glass/polymer composite scaffold was developed for the repair of load-bearing bones with high flexural strength and without brittle behavior. The new composites have 2.5 times higher flexural strength and ˜100 times higher work of fracture (without catastrophic failure) compared to a similar bare glass scaffold. Also the use of two known bioactive glasses (13-93-B3 and 45S5) was investigated in developing glass/Poly(epsilon-caprolactone) (PCL) composite films for peripheral nerve repair. It was found that a layer of globular hydroxyapatite (HA) formed on both sides of the composites. The borate glass in the composites was fully reacted in SBF and different ions were released into the solution. The addition of bioactive glass particles to the PCL lowered its elastic modulus and yield strength, but the composites remained intact after the 14 day period in SBF at 37°C. Finally, in an effort to design a better bioactive glass, new borosilicate glass compositions were developed that possess advantages of borate and silicate bioactive glasses at the same time. It was found that replacing small amounts of B2O3 with SiO2 improved glass formation, resistance to nucleation and crystallization, and increased the release rate of boron and silicon in vitro. This new borosilicate glass could be a good alternative to existing silicate and borate bioactive glasses.

  19. Mechanical characterization of composite repairs for fiberglass wind turbine blades

    NASA Astrophysics Data System (ADS)

    Chawla, Tanveer Singh

    While in service, wind turbine blades experience various modes of loading. An example is impact loading in the form of hail or bird strikes, which might lead to localized damage or formation of cracks a few plies deep on the blade surface. One of the methods to conduct repairs on wind turbine blades that are damaged while in service is hand lay-up of the repair part after grinding out the damaged portion and some of its surrounding area. The resin used for such repairs usually differs from the parent plate resin in composition and properties such as gel time, viscosity, etc. As a result the properties of the repaired parts are not the same as that of the undamaged blades. Subsequent repetitive loading can be detrimental to weak repairs to such an extent so as to cause delamination at the parent-repair bondline causing the repairs to eventually fall off the blade. Thus the strength and toughness of the repair are of critical importance. Initial part of this work consists of an effort to increase repair strength by identifying an optimum hand layup repair resin for fiberglass wind turbine blades currently being manufactured by a global company. As delamination of the repair from the parent blade is a major concern and unidirectional glass fibers along with a polymer resin are used to manufacture blades under consideration, testing method detailed in ASTM D 5528 (Test Method for Mode I Interlaminar Fracture Toughness of Unidirectional Fiber-Reinforced Polymer Matrix Composites) was followed to determine propagation fracture toughness values of the prospective vinyl ester repair resin candidates. These values were compared to those for a base polyester repair resin used by the company. Experimental procedure and results obtained from the above mentioned testing using double cantilever beam (DCB) specimens are detailed. Three new repair resins were shortlisted through mode I testing. It was also found that variation in the depth of the ground top ply of the parent part affects the propagation fracture toughness values of the repair. Repairs conducted on surfaces with partially ground top plies possess higher fracture toughness values than those conducted on surfaces with complete top plies ground off. The three top repair resin candidates were then evaluated against the base repair resin under fatigue loading. The specimen configuration and testing method were chosen so as to be able to test hand layup repairs under tension -- tension cyclic loading. It was observed that all three new repair resins perform better than the base repair resin. The selection of the optimum repair resin was based on results from mode I and fatigue testing. Global manufacturing regulations and standards were also of prime concern. The final new repair resin is being used by the company in all of its plants over the globe. The balance of this work involves study of the effect of mixed mode I -- mode II loading on the strength of repairs conducted on fiber reinforced composite parts using hand lay-up technique. The specimens for this part were similar to those manufactured for mode I testing but with different dimensions and layup. They were made and tested in accordance with ASTM D 6671 (Standard Test Method for Mixed Mode I -- Mode II Interlaminar Fracture Toughness of Unidirectional Fiber Reinforced Polymer Matrix Composites). Comparison was made between the fracture toughness of the above chosen optimum repair resin and the base repair resin. At least two levels of mode mixture GII/G (Mode II fracture toughness / Mode I and II fracture toughness) were examined. Also, two levels of grinding were considered (complete ply vs. partial ply ground off) in order to establish the influence of varying top-ply grinding depths on the strength of hand layup repairs conducted on fiberglass composite structures. The results of this work have the potential to improve the repair process for current fiberglass wind turbine blades.

  20. Simple patch closure for perforated peptic ulcer in children followed by helicobacter pylori eradication.

    PubMed

    Yildiz, Turan; Ilce, Huri Tilla; Ceran, Canan; Ilce, Zekeriya

    2014-05-01

    Peptic ulcer disease in children is rare. Therefore, the diagnosis can be missed until complications such as perforation or hemorrhage occur. Few reports have investigated the procedures and outcomes of children who have undergone operations for perforated duodenal ulcers. We report our experience with the modified Graham technique for perforated duodenal ulcers in nine children and review the literature. Methods : The records of patients operated on for a perforated duodenal ulcer in the last 8 years in two pediatric surgery centers were evaluated retrospectively. Patient demographics, symptoms, time to admission to hospital, operative findings, and postoperative clinical course were evaluated. Results : Nine children (mean age 13.2 years, range 6-170 years) were included. All patients were admitted in the first six hours after their abdominal pain started. In three patients, there was free air on plain x-rays, while the x-rays were normal in six. All perforations were located on the anterior surface of the first part of the duodenum and repaired with primary suturing and Graham patch omentoplasty. The recovery was uneventful in all patients. In five patients, urea breath tests were performed postoperatively for Helicobacter Pylori, and the results were positive. All patients underwent triple therapy with lansoprazole, amoxicillin, and clarithromycin. The mean follow-up time was 58 (range 3-94) months. Conclusions : Peptic ulcer perforation should be suspected in children who have acute abdominal pain and peritoneal signs, especially when their suffering is intense. The simple patch repair and postoperative triple therapy for Helicobacter Pylori are safe and satisfactory for treating peptic ulcer perforation in children.

  1. Improving left ventricular outflow tract obstruction repair in common atrioventricular canal defects.

    PubMed

    Myers, Patrick O; del Nido, Pedro J; Marx, Gerald R; Emani, Sitaram; Mayer, John E; Pigula, Frank A; Baird, Christopher W

    2012-08-01

    Left ventricular outflow tract obstruction (LVOTO) is the second most frequent reason for reoperation after atrioventricular canal (AVC) defect repair. Limited data are available on the mechanisms of LVOTO, their treatment, and outcomes. Between 1998 and 2010, 56 consecutive children with AVC underwent 68 LVOTO procedures. The AVC was partial in 4, transitional in 9, and complete in 43. The LVOTO procedure was required in 21 patients at the primary AVC repair, and the initial LVOTO procedure in 35 patients was a late reoperation after AVC repair. During a mean follow-up of 50±41 months, 5 patients (24%) with LVOTO repair at AVC repair required a reoperation for LVOTO, and 7 patients (20%) whose initial LVOTO repair was a reoperation required a second reoperation for LVOTO repair. Overall freedom from LVOTO reoperation was 98.5% at 1 year, 92.5% at 3 years, 81% at 5 years, 72.2% at 7 years, and 52.5% at 10 and 12 years. The freedom from reoperation was neither significantly different between partial, transitional, and complete AVC (p=0.78) nor between timing of the LVOT procedure (p=0.49). Modified single-patch AVC repair was associated with a higher LVOTO reoperation rate (p=0.04). Neither the mechanisms leading to LVOTO nor the surgical techniques used were independent predictors of reoperation. LVOTO in AVC is a complex and multifactorial disease. Aggressive surgical repair has improved late outcomes; however, risk factors for reoperation and the ideal approach for repair remain to be defined. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Conserving Tropical Tree Diversity and Forest Structure: The Value of Small Rainforest Patches in Moderately-Managed Landscapes

    PubMed Central

    Hernández-Ruedas, Manuel A.; Arroyo-Rodríguez, Víctor; Meave, Jorge A.; Martínez-Ramos, Miguel; Ibarra-Manríquez, Guillermo; Martínez, Esteban; Jamangapé, Gilberto; Melo, Felipe P. L.; Santos, Bráulio A.

    2014-01-01

    Rainforests are undergoing severe deforestation and fragmentation worldwide. A huge amount of small forest patches are being created, but their value in conserving biodiversity and forest structure is still controversial. Here, we demonstrate that in a species-rich and moderately-managed Mexican tropical landscape small rainforest patches (<100 ha) can be highly valuable for the conservation of tree diversity and forest structure. These patches showed diverse communities of native plants, including endangered species, and a new record for the country. Although the number of logged trees increased in smaller patches, patch size was a poor indicator of basal area, stem density, number of species, genera and families, and community evenness. Cumulative species-area curves indicated that all patches had a similar contribution to the regional species diversity. This idea also was supported by the fact that patches strongly differed in floristic composition (high β-diversity), independently of patch size. Thus, in agreement with the land-sharing approach, our findings support that small forest patches in moderately-managed landscapes should be included in conservation initiatives to maintain landscape heterogeneity, species diversity, and ecosystem services. PMID:24901954

  3. Conserving tropical tree diversity and forest structure: the value of small rainforest patches in moderately-managed landscapes.

    PubMed

    Hernández-Ruedas, Manuel A; Arroyo-Rodríguez, Víctor; Meave, Jorge A; Martínez-Ramos, Miguel; Ibarra-Manríquez, Guillermo; Martínez, Esteban; Jamangapé, Gilberto; Melo, Felipe P L; Santos, Bráulio A

    2014-01-01

    Rainforests are undergoing severe deforestation and fragmentation worldwide. A huge amount of small forest patches are being created, but their value in conserving biodiversity and forest structure is still controversial. Here, we demonstrate that in a species-rich and moderately-managed Mexican tropical landscape small rainforest patches (<100 ha) can be highly valuable for the conservation of tree diversity and forest structure. These patches showed diverse communities of native plants, including endangered species, and a new record for the country. Although the number of logged trees increased in smaller patches, patch size was a poor indicator of basal area, stem density, number of species, genera and families, and community evenness. Cumulative species-area curves indicated that all patches had a similar contribution to the regional species diversity. This idea also was supported by the fact that patches strongly differed in floristic composition (high β-diversity), independently of patch size. Thus, in agreement with the land-sharing approach, our findings support that small forest patches in moderately-managed landscapes should be included in conservation initiatives to maintain landscape heterogeneity, species diversity, and ecosystem services.

  4. Importance of ecotone type to landscape dynamics at biome transition zones

    USDA-ARS?s Scientific Manuscript database

    Landscapes in biome transition zones consist of a mosaic of patches dominated or codominated by species from adjacent biomes. Shifts in the vegetation composition and dynamics of a biome transition zone depend upon the underlying patch dynamics of the ecotones between these dominant species. Landsc...

  5. Gradient modeling of conifer species using random forests

    Treesearch

    Jeffrey S. Evans; Samuel A. Cushman

    2009-01-01

    Landscape ecology often adopts a patch mosaic model of ecological patterns. However, many ecological attributes are inherently continuous and classification of species composition into vegetation communities and discrete patches provides an overly simplistic view of the landscape. If one adopts a nichebased, individualistic concept of biotic communities then it may...

  6. Stiffness and strength of fiber reinforced polymer composite bridge deck systems

    NASA Astrophysics Data System (ADS)

    Zhou, Aixi

    This research investigates two principal characteristics that are of primary importance in Fiber Reinforced Polymer (FRP) bridge deck applications: STIFFNESS and STRENGTH. The research was undertaken by investigating the stiffness and strength characteristics of the multi-cellular FRP bridge deck systems consisting of pultruded FRP shapes. A systematic analysis procedure was developed for the stiffness analysis of multi-cellular FRP deck systems. This procedure uses the Method of Elastic Equivalence to model the cellular deck as an equivalent orthotropic plate. The procedure provides a practical method to predict the equivalent orthotropic plate properties of cellular FRP decks. Analytical solutions for the bending analysis of single span decks were developed using classical laminated plate theory. The analysis procedures can be extended to analyze continuous FRP decks. It can also be further developed using higher order plate theories. Several failure modes of the cellular FRP deck systems were recorded and analyzed through laboratory and field tests and Finite Element Analysis (FEA). Two schemes of loading patches were used in the laboratory test: a steel patch made according to the ASSHTO's bridge testing specifications; and a tire patch made from a real truck tire reinforced with silicon rubber. The tire patch was specially designed to simulate service loading conditions by modifying real contact loading from a tire. Our research shows that the effects of the stiffness and contact conditions of loading patches are significant in the stiffness and strength testing of FRP decks. Due to the localization of load, a simulated tire patch yields larger deflection than the steel patch under the same loading level. The tire patch produces significantly different failure compared to the steel patch: a local bending mode with less damage for the tire patch; and a local punching-shear mode for the steel patch. A deck failure function method is proposed for predicting the failure of FRP decks. Using developed laminated composite theories and FEA techniques, a strength analysis procedure containing ply-level information was proposed and detailed for FRP deck systems. The behavior of the deck's unsupported (free) edges was also investigated using ply-level FEA.

  7. Microshear bond strength and finite element analysis of resin composite adhesion to press-on-metal ceramic for repair actions after various conditioning methods.

    PubMed

    Kanat, Burcu; Cömlekoğlu, M Erhan; Cömlekoğlu, Mine Dündar; Culha, Osman; Ozcan, Mutlu; Güngör, Mehmet Ali

    2014-02-01

    This study evaluated the repair bond strength of differently surface-conditioned press-on-metal ceramic to repair composites and determined the location of the accumulated stresses by finite element analysis. Press-on-metal ceramic disks (IPS InLine PoM, Ivoclar Vivadent) (N = 45, diameter: 3 mm, height: 2 mm) were randomly divided into 3 groups (n = 15 per group) and conditioned with one of the following methods: 9.5% hydrofluoric acid (HF) (Porcelain etch), tribochemical silica coating (TS) (CoJet), and an unconditioned group acted as the control (C). Each group was divided into three subgroups depending on the repair composite resins: a) Arabesk Top (V, a microhybrid; VOCO), b) Filtek Z250 (F, a hybrid;3M ESPE); c) Tetric EvoCeram (T, a nanohybrid; Ivoclar Vivadent) (n = 5 per subgroup). Repair composites disks (diameter: 1 mm, height: 1 mm) were photopolymerized on each ceramic block. Microshear bond strength (MSB) tests were performed (1 mm/min) and the obtained data were statistically analyzed using 2-way ANOVA and Tukey's post-hoc test (α = 0.05). Failure types were analyzed under SEM. Vickers indentation hardness, Young's modulus, and finite element analysis (FEA) were performed complementary to MSB tests to determine stress accumulation areas. MSB results were significantly affected by the surface conditioning methods (p = 0.0001), whereas the repair composite types did not show a significant effect (p = 0.108). The interaction terms between the repair composite and surface conditioning method were also statistically significant (p = 0.0001). The lowest MSB values (MPa ± SD) were obtained in the control group (V = 4 ± 0.8; F = 3.9 ± 0.7; T = 4.1 ± 0.7) (p < 0.05). While the group treated with T composite resulted in significantly lower MSB values for the HF group (T= 4.1 ± 0.8) compared to those of other composites (V = 8.1 ± 2.6; F = 7.6 ± 2.2) (p < 0.05), there were no significant differences when TS was used as a conditioning method (V = 5 ± 1.7; F = 4.7 ± 1; T = 6.2 ± 0.8) (p > 0.05). The control group presented exclusively adhesive failures. Cohesive failures in composite followed by mixed failure types were more common in HF and TS conditioned groups. Elasticity modulus of the composites were 22.9, 12.09, and 10.41 GPa for F, T, and V, respectively. Vickers hardness of the composites were 223, 232, and 375 HV for V, T, and F, respectively. Von Mises stresses in the FEA analysis for the V and T composites spread over a large area due to the low elastic modulus of the composite, whereas the F composite material accumulated more stresses at the bonded interface. Press-on-metal ceramic could best be repaired using tribochemical silica coating followed by silanization, regardless of the repair composite type in combination with their corresponding adhesive resins, providing that no cohesive ceramic failure was observed.

  8. Computer generated holographic microtags

    DOEpatents

    Sweatt, William C.

    1998-01-01

    A microlithographic tag comprising an array of individual computer generated holographic patches having feature sizes between 250 and 75 nanometers. The tag is a composite hologram made up of the individual holographic patches and contains identifying information when read out with a laser of the proper wavelength and at the proper angles of probing and reading. The patches are fabricated in a steep angle Littrow readout geometry to maximize returns in the -1 diffracted order. The tags are useful as anti-counterfeiting markers because of the extreme difficulty in reproducing them.

  9. Bone-to-bone Fixation Enhances Functional Healing of the Porcine Anterior Cruciate Ligament Using a Collagen-Platelet Composite

    PubMed Central

    Murray, Martha M.; Magarian, Elise; Zurakowski, David; Fleming, Braden C.

    2010-01-01

    Purpose The purpose of this study was to determine if providing bony stabilization between the tibia and femur would improve the structural properties of an “enhanced” ACL repair using a collagen-platelet composite when compared to the traditional (Marshall) suture technique. Methods Twelve pigs underwent unilateral ACL transection and were treated with sutures connecting the bony femoral ACL attachment site to the distal ACL stump (LIGAMENT group), or to the tibia via a bone tunnel (TIBIA group). A collagen-platelet composite was placed around the sutures to enhance the biologic repair in both groups. Anteroposterior (AP) knee laxity and the graft structural properties were measured after 15 weeks of healing in both the ACL-repaired and contralateral ACL-intact joints. Results Enhanced ACL repair with bone-to-bone fixation significantly improved yield load and linear stiffness of the ACL repairs (p<0.05) after 15 weeks of healing. However, laxity values of the knees were similar in both groups of repaired knees (p>0.10). Conclusions Using an enhanced ACL suture repair technique that includes bone-to-bone fixation to protect the repair in the initial healing stages resulted in an ACL with improved structural properties after 15 weeks in the porcine model. Clinical Relevance The healing response of an ACL suture repair using a collagen-platelet composite can be enhanced by providing bony stabilization between the tibia and femur to protect the graft during the initial healing process in a translational model. PMID:20810092

  10. Effect of Er,Cr:YSGG laser, air abrasion, and silane application on repaired shear bond strength of composites.

    PubMed

    Cho, S D; Rajitrangson, P; Matis, B A; Platt, J A

    2013-01-01

    Aged resin composites have a limited number of carbon-carbon double bonds to adhere to a new layer of resin. Study objectives were to 1) evaluate various surface treatments on repaired shear bond strength between aged and new resin composites and 2) to assess the influence of a silane coupling agent after surface treatments. Eighty disk-shape resin composite specimens were fabricated and thermocycled 5000 times prior to surface treatment. Specimens were randomly assigned to one of the three surface treatment groups (n=20): 1) air abrasion with 50-μm aluminum oxide, 2) tribochemical silica coating (CoJet), or 3) Er,Cr:YSGG (erbium, chromium: yttrium-scandium-gallium-garnet) laser or to a no-treatment control group (n=20). Specimens were etched with 35% phosphoric acid, rinsed, and dried. Each group was divided into two subgroups (n=10): A) no silanization and B) with silanization. The adhesive agent was applied and new resin composite was bonded to each conditioned surface. Shear bond strength was evaluated and data analyzed using two-way analysis of variance (ANOVA). Air abrasion with 50-μm aluminum oxide showed significantly higher repair bond strength than the Er,Cr:YSGG laser and control groups. Air abrasion with 50-μm aluminum oxide was not significantly different from tribochemical silica coating. Tribochemical silica coating had significantly higher repair bond strength than Er,Cr:YSGG laser and the control. Er,Cr:YSGG laser and the control did not have significantly different repair bond strengths. Silanization had no influence on repair bond strength for any of the surface treatment methods. Air abrasion with 50-μm aluminum oxide and tribochemical silica followed by the application of bonding agent provided the highest repair shear bond strength values, suggesting that they might be adequate methods to improve the quality of repairs of resin composites.

  11. Hydrologic connection between ponds positively affects macrophyte alpha and gamma diversity but negatively affects beta diversity.

    PubMed

    Akasaka, Munemitsu; Takamura, Noriko

    2012-05-01

    Connections between habitat patches can positively influence the number of species in respective patches, providing a basis for preferentially conserving interconnected patches. However, from a regional perspective, it is not known whether conserving multiple sets of interconnected habitat patches would include more species (i.e., show higher gamma diversity) than conserving multiple, unconnected, solitary patches. We studied aquatic macrophytes in 15 sets of unidirectionally interconnected ponds and 19 unconnected ponds and also tested whether alpha and beta diversity, expressed as the number of species and dissimilarity in species composition, respectively, differed between connected and unconnected ponds. We found that gamma diversity was higher in connected ponds than in unconnected ponds, even after controlling for surface area. This resulted from a higher alpha diversity in connected ponds, despite lower beta diversity. These results suggest that connections between habitat patches positively influence diversity at both local and regional scales. When the total surface area available for conservation is limited, interconnected habitat patches should be preferentially conserved.

  12. Repair of bis-acryl provisional restorations using flowable composite resin.

    PubMed

    Bohnenkamp, David M; Garcia, Lily T

    2004-11-01

    Provisional restorations provide interim coverage for prepared teeth while fixed definitive restorations are fabricated. Several types of autopolymerizing acrylic resins have been used for many years to fabricate provisional restorations. In recent years, bis-acryl resin composite material has gained popularity among clinicians for the direct fabrication of provisional fixed restorations. Occasionally, deficiencies may occur while fabricating a direct provisional restoration and require chairside repair. This article describes an effective procedure for the use of light-polymerized flowable composite resin for the intraoral repair of bis-acryl provisional restorations.

  13. Preparation of active 3D film patches via aligned fiber electrohydrodynamic (EHD) printing

    NASA Astrophysics Data System (ADS)

    Wang, Jun-Chuan; Zheng, Hongxia; Chang, Ming-Wei; Ahmad, Zeeshan; Li, Jing-Song

    2017-03-01

    The design, preparation and application of three-dimensional (3D) printed structures have gained appreciable interest in recent times, particularly for drug dosage development. In this study, the electrohydrodynamic (EHD) printing technique was developed to fabricate aligned-fiber antibiotic (tetracycline hydrochloride, TE-HCL) patches using polycaprolactone (PCL), polyvinyl pyrrolidone (PVP) and their composite system (PVP-PCL). Drug loaded 3D patches possessed perfectly aligned fibers giving rise to fibrous strut orientation, variable inter-strut pore size and controlled film width (via layering). The effect of operating parameters on fiber deposition and alignment were explored, and the impact of the film structure, composition and drug loading was evaluated. FTIR demonstrated successful TE-HCL encapsulation in aligned fibers. Patches prepared using PVP and TE-HCL displayed enhanced hydrophobicity. Tensile tests exhibited changes to mechanical properties arising from additive effects. Release of antibiotic from PCL-PVP dosage forms was shown over 5 days and was slower compared to pure PCL or PVP. The printed patch void size also influenced antibiotic release behavior. The EHDA printing technique provides an exciting opportunity to tailor dosage forms in a single-step with minimal excipients and operations. These developments are crucial to meet demands where dosage forms cannot be manufactured rapidly or when a personalized approach is required.

  14. Preparation of active 3D film patches via aligned fiber electrohydrodynamic (EHD) printing

    PubMed Central

    Wang, Jun-Chuan; Zheng, Hongxia; Chang, Ming-Wei; Ahmad, Zeeshan; Li, Jing-Song

    2017-01-01

    The design, preparation and application of three-dimensional (3D) printed structures have gained appreciable interest in recent times, particularly for drug dosage development. In this study, the electrohydrodynamic (EHD) printing technique was developed to fabricate aligned-fiber antibiotic (tetracycline hydrochloride, TE-HCL) patches using polycaprolactone (PCL), polyvinyl pyrrolidone (PVP) and their composite system (PVP-PCL). Drug loaded 3D patches possessed perfectly aligned fibers giving rise to fibrous strut orientation, variable inter-strut pore size and controlled film width (via layering). The effect of operating parameters on fiber deposition and alignment were explored, and the impact of the film structure, composition and drug loading was evaluated. FTIR demonstrated successful TE-HCL encapsulation in aligned fibers. Patches prepared using PVP and TE-HCL displayed enhanced hydrophobicity. Tensile tests exhibited changes to mechanical properties arising from additive effects. Release of antibiotic from PCL-PVP dosage forms was shown over 5 days and was slower compared to pure PCL or PVP. The printed patch void size also influenced antibiotic release behavior. The EHDA printing technique provides an exciting opportunity to tailor dosage forms in a single-step with minimal excipients and operations. These developments are crucial to meet demands where dosage forms cannot be manufactured rapidly or when a personalized approach is required. PMID:28272513

  15. Preparation of porous PLA/DBM composite biomaterials and experimental research of repair rabbit radius segmental bone defect.

    PubMed

    Zhang, Yumin; Wang, Jianru; Wang, Jue; Niu, Xiaojun; Liu, Jianchun; Gao, Lan; Zhai, Xiaoyan; Chu, Kaibo

    2015-12-01

    Bone substitutes are used in wide range of orthopaedic application. An ideal bone substitute should exhibit superior osteoinductive and osteoconductive properties. Neither bio-derived materials nor synthetic materials can meet the needs of an ideal bone substitute. Preparation of composite materials is a promising way to improve properties of biomaterial. In this study, the porous poly lactic acid (PLA)/demineralized bone matrix (DBM) composite biomaterials prepared by supercritical CO2 technique were implanted to repair rabbit radius segmental bone defect. By comparing with PLA and bone autograft, the X-ray result and histological analysis showed the repair effect of PLA/DBM porous composite materials is significantly better than that of the PLA group and the blank control group, and is similar to autologous bone. The PLA/DBM can promote the healing of bone defects and can be used as a kind of ideal alternative materials to repair bone defects.

  16. Effect of curing and silanizing on composite repair bond strength using an improved micro-tensile test method

    PubMed Central

    Eliasson, Sigfus Thor; Dahl, Jon E.

    2017-01-01

    Abstract Objectives: To evaluate the micro-tensile repair bond strength between aged and new composite, using silane and adhesives that were cured or left uncured when new composite was placed. Methods: Eighty Filtek Supreme XLT composite blocks and four control blocks were stored in water for two weeks and thermo-cycled. Sandpaper ground, etched and rinsed specimens were divided into two experimental groups: A, no further treatment and B, the surface was coated with bis-silane. Each group was divided into subgroups: (1) Adper Scotchbond Multi-Purpose, (2) Adper Scotchbond Multi-Purpose adhesive, (3) Adper Scotchbond Universal, (4) Clearfil SE Bond and (5) One Step Plus. For each adhesive group, the adhesive was (a) cured according to manufacturer’s instructions or (b) not cured before repair. The substrate blocks were repaired with Filtek Supreme XLT. After aging, they were serially sectioned, producing 1.1 × 1.1 mm square test rods. The rods were prepared for tensile testing and tensile strength calculated at fracture. Type of fracture was examined under microscope. Results: Leaving the adhesive uncured prior to composite repair placement increased the mean tensile values statistically significant for all adhesives tested, with or without silane pretreatment. Silane surface treatment improved significantly (p < 0.001) tensile strength values for all adhesives, both for the cured and uncured groups. The mean strength of the control composite was higher than the strongest repair strength (p < 0.001). Conclusions: Application of freshly made silane and a thin bonding layer, rendered higher tensile bond strength. Not curing the adhesive before composite placement increased the tensile bond strength. PMID:28642928

  17. Proximity to AGCT sequences dictates MMR-independent versus MMR-dependent mechanisms for AID-induced mutation via UNG2

    PubMed Central

    Thientosapol, Eddy Sanchai; Sharbeen, George; Lau, K.K. Edwin; Bosnjak, Daniel; Durack, Timothy; Stevanovski, Igor; Weninger, Wolfgang

    2017-01-01

    Abstract AID deaminates C to U in either strand of Ig genes, exclusively producing C:G/G:C to T:A/A:T transition mutations if U is left unrepaired. Error-prone processing by UNG2 or mismatch repair diversifies mutation, predominantly at C:G or A:T base pairs, respectively. Here, we show that transversions at C:G base pairs occur by two distinct processing pathways that are dictated by sequence context. Within and near AGCT mutation hotspots, transversion mutation at C:G was driven by UNG2 without requirement for mismatch repair. Deaminations in AGCT were refractive both to processing by UNG2 and to high-fidelity base excision repair (BER) downstream of UNG2, regardless of mismatch repair activity. We propose that AGCT sequences resist faithful BER because they bind BER-inhibitory protein(s) and/or because hemi-deaminated AGCT motifs innately form a BER-resistant DNA structure. Distal to AGCT sequences, transversions at G were largely co-dependent on UNG2 and mismatch repair. We propose that AGCT-distal transversions are produced when apyrimidinic sites are exposed in mismatch excision patches, because completion of mismatch repair would require bypass of these sites. PMID:28039326

  18. A unified view of base excision repair: lesion-dependent protein complexes regulated by post-translational modification

    PubMed Central

    Almeida, Karen H.; Sobol, Robert W.

    2007-01-01

    Base excision repair (BER) proteins act upon a significantly broad spectrum of DNA lesions that result from endogenous and exogenous sources. Multiple sub-pathways of BER (short-path or long-patch) and newly designated DNA repair pathways (e.g., SSBR and NIR) that utilize BER proteins complicate any comprehensive understanding of BER and its role in genome maintenance, chemotherapeutic response, neurodegeneration, cancer or aging. Herein, we propose a unified model of BER, comprised of three functional processes: Lesion Recognition/Strand Scission, Gap Tailoring and DNA Synthesis/Ligation, each represented by one or more multiprotein complexes and coordinated via the XRCC1/DNA Ligase III and PARP1 scaffold proteins. BER therefore may be represented by a series of repair complexes that assemble at the site of the DNA lesion and mediates repair in a coordinated fashion involving protein-protein interactions that dictate subsequent steps or sub-pathway choice. Complex formation is influenced by post-translational protein modifications that arise from the cellular state or the DNA damage response, providing an increase in specificity and efficiency to the BER pathway. In this review, we have summarized the reported BER protein-protein interactions and protein post-translational modifications and discuss the impact on DNA repair capacity and complex formation. PMID:17337257

  19. The effect of heterogeneous landscape dynamics on ecotone types at two convergent semi-arid biomes

    USDA-ARS?s Scientific Manuscript database

    Landscapes in biome transition zones consist of a mosaic of patches dominated or codominated by species from adjacent biomes. Shifts in the vegetation composition and dynamics of a biome transition zone depend upon the underlying patch dynamics of the ecotones between these dominant species. Landsca...

  20. Understory vegetation and site factors : implications for a managed Wisconsin landscape

    Treesearch

    K.D. Brosofske; J. Chen; Thomas R. Crow

    2001-01-01

    We investigated relationships between edaphic and environmental factors (soil, forest floor, topography, and canopy) and understory vegetation (composition, richness, and Shannon-Wiener diversity index, H')among 77 plots representing seven major patch types comprising a landscape in northern Wisconsin that has a long history of human management. Sampled patch...

  1. Laser welding versus suturing in tunica vaginalis and venous patch graft corporoplasty.

    PubMed

    Kirsch, A J; Chang, D T; Miller, M I; Connor, J P; Hensle, T W; Shabsigh, R

    1995-08-01

    Congenital penile curvature may result from corporeal disproportion in nearly 40% of cases, while in adults scarring of the corporeal bodies or periurethral fibrosis accounts for the majority of cases. Some surgeons advocate lengthening the fibrosed corporeal bodies by excising tunica albuginea and grafting such defects to straighten the penis. Tunica vaginalis, dermis, dorsal vein and lyophilized dura have been used for this purpose. Traditionally, these graft biomaterials have been sutured to the tunica albuginea. We assessed the feasibility, short-term safety and efficacy of diode laser tissue welding using albumin based solder and indocyanine green dye to perform patch graft corporoplasty in the dog. Ten animals were subjected to bilateral transverse excision of 1 x 2 cm. sections of tunica albuginea. Corporoplasty was performed using grafts composed of saphenous vein (5) or tunica vaginalis (5). Microsurgical repair with 7-zero polydioxanone suture (10) was compared to contralateral laser welded repair (10) by recording operative time, initial and short-term bursting pressures (mean plus or minus standard deviation) and histological analysis. Operative time on the laser side (9.8 +/- 2.3 minutes) was significantly shorter (p < 0.05) than on the suture side (17.1 +/- 5.1 minutes). Leak pressures, initially (laser 105.7 +/- 23.8 mm. Hg versus suture 35.3 +/- 8.0 mm. Hg), at 3 to 5 days (greater than 333.3 +/- 62.4 mm. Hg versus 136.6 +/- 39.4 mm. Hg) and at 7 to 10 days (greater than 397.8 +/- 39.8 mm. Hg versus 191.5 +/- 46.4 mm. Hg) were higher (p < 0.05) in the laser side compared to controls. Graft failure (necrosis) occurred in 3 repairs (2 laser on day 4 and 1 suture on day 10). Viable tissue with minimal differences in foreign body reaction between groups was observed in the remaining grafts. We conclude that laser welded patch graft corporoplasty using tunica vaginalis or vein is easy to perform, and provides excellent initial and short-term leak pressures. The use of laser welding in conjunction with suturing may be beneficial in corporoplasty for congenital or acquired penile curvature.

  2. Removal of N-6-methyladenine by the nucleotide excision repair pathway triggers the repair of mismatches in yeast gap-repair intermediates.

    PubMed

    Guo, Xiaoge; Jinks-Robertson, Sue

    2013-12-01

    Gap-repair assays have been an important tool for studying the genetic control of homologous recombination in yeast. Sequence analysis of recombination products derived when a gapped plasmid is diverged relative to the chromosomal repair template additionally has been used to infer structures of strand-exchange intermediates. In the absence of the canonical mismatch repair pathway, mismatches present in these intermediates are expected to persist and segregate at the next round of DNA replication. In a mismatch repair defective (mlh1Δ) background, however, we have observed that recombination-generated mismatches are often corrected to generate gene conversion or restoration events. In the analyses reported here, the source of the aberrant mismatch removal during gap repair was examined. We find that most mismatch removal is linked to the methylation status of the plasmid used in the gap-repair assay. Whereas more than half of Dam-methylated plasmids had patches of gene conversion and/or restoration interspersed with unrepaired mismatches, mismatch removal was observed in less than 10% of products obtained when un-methylated plasmids were used in transformation experiments. The methylation-linked removal of mismatches in recombination intermediates was due specifically to the nucleotide excision repair pathway, with such mismatch removal being partially counteracted by glycosylases of the base excision repair pathway. These data demonstrate that nucleotide excision repair activity is not limited to bulky, helix-distorting DNA lesions, but also targets removal of very modest perturbations in DNA structure. In addition to its effects on mismatch removal, methylation reduced the overall gap-repair efficiency, but this reduction was not affected by the status of excision repair pathways. Finally, gel purification of DNA prior to transformation reduced gap-repair efficiency four-fold in a nucleotide excision repair-defective background, indicating that the collateral introduction of UV damage can potentially compromise genetic interpretations. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Removal of N-6-methyladenine by the nucleotide excision repair pathway triggers the repair of mismatches in yeast gap-repair intermediates

    PubMed Central

    Guo, Xiaoge; Jinks-Robertson, Sue

    2013-01-01

    Gap-repair assays have been an important tool for studying the genetic control of homologous recombination in yeast. Sequence analysis of recombination products derived when a gapped plasmid is diverged relative to the chromosomal repair template additionally has been used to infer structures of strand-exchange intermediates. In the absence of the canonical mismatch repair pathway, mismatches present in these intermediates are expected to persist and segregate at the next round of DNA replication. In a mismatch repair defective (mlh1Δ) background, however, we have observed that recombination-generated mismatches are often corrected to generate gene conversion or restoration events. In the analyses reported here, the source of the aberrant mismatch removal during gap repair was examined. We find that most mismatch removal is linked to the methylation status of the plasmid used in the gap-repair assay. Whereas more than half of Dam-methylated plasmids had patches of gene conversion and/or restoration interspersed with unrepaired mismatches, mismatch removal was observed in less than 10% of products obtained when un-methylated plasmids were used in transformation experiments. The methylation-linked removal of mismatches in recombination intermediates was due specifically to the nucleotide excision repair pathway, with such mismatch removal being partially counteracted by glycosylases of the base excision repair pathway. These data demonstrate that nucleotide excision repair activity is not limited to bulky, helix-distorting DNA lesions, but also targets removal of very modest perturbations in DNA structure. In addition to its effects on mismatch removal, methylation reduced the overall gap-repair efficiency, but this reduction was not affected by the status of excision repair pathways. Finally, gel purification of DNA prior to transformation reduced gap-repair efficiency four-fold in a nucleotide excision repair-defective background, indicating that the cillateral introduction of UV damage can potentially compromise genetic interpretations. PMID:24120148

  4. Linking potential heat source and sink to urban heat island: Heterogeneous effects of landscape pattern on land surface temperature.

    PubMed

    Li, Weifeng; Cao, Qiwen; Lang, Kun; Wu, Jiansheng

    2017-05-15

    Rapid urbanization has significantly contributed to the development of urban heat island (UHI). Regulating landscape composition and configuration would help mitigate the UHI in megacities. Taking Shenzhen, China, as a case study area, we defined heat source and heat sink and identified strong and weak sources as well as strong and weak sinks according to the natural and socioeconomic factors influencing land surface temperature (LST). Thus, the potential thermal contributions of heat source and heat sink patches were differentiated. Then, the heterogeneous effects of landscape pattern on LST were examined by using semiparametric geographically weighted regression (SGWR) models. The results showed that landscape composition has more significant effects on thermal environment than configuration. For a strong source, the percentage of patches has a positive impact on LST. Additionally, when mosaicked with some heat sink, even a small improvement in the degree of dispersion of a strong source helps to alleviate UHI. For a weak source, the percentage and density of patches have positive impacts on LST. For a strong sink, the percentage, density, and degree of aggregation of patches have negative impacts on LST. The effects of edge density and patch shape complexity vary spatially with the fragmentation of a strong sink. Similarly, the impacts of a weak sink are mainly exerted via the characteristics of percent, density, and shape complexity of patches. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Detection of Delamination in Composite Beams Using Broadband Acoustic Emission Signatures

    NASA Technical Reports Server (NTRS)

    Okafor, A. C.; Chandrashekhara, K.; Jiang, Y. P.

    1996-01-01

    Delamination in composite structure may be caused by imperfections introduced during the manufacturing process or by impact loads by foreign objects during the operational life. There are some nondestructive evaluation methods to detect delamination in composite structures such as x-radiography, ultrasonic testing, and thermal/infrared inspection. These methods are expensive and hard to use for on line detection. Acoustic emission testing can monitor the material under test even under the presence of noise generated under load. It has been used extensively in proof-testing of fiberglass pressure vessels and beams. In the present work, experimental studies are conducted to investigate the use of broadband acoustic emission signatures to detect delaminations in composite beams. Glass/epoxy beam specimens with full width, prescribed delamination sizes of 2 inches and 4 inches are investigated. The prescribed delamination is produced by inserting Teflon film between laminae during the fabrication of composite laminate. The objectives of this research is to develop a method for predicting delamination size and location in laminated composite beams by combining smart materials concept and broadband AE analysis techniques. More specifically, a piezoceramic (PZT) patch is bonded on the surface of composite beams and used as a pulser. The piezoceramic patch simulates the AE wave source as a 3 cycles, 50KHz, burst sine wave. One broadband AE sensor is fixed near the PZT patch to measure the AE wave near the AE source. A second broadband AE sensor, which is used as a receiver, is scanned along the composite beams at 0.25 inch step to measure propagation of AE wave along the composite beams. The acquired AE waveform is digitized and processed. Signal strength, signal energy, cross-correlation of AE waveforms, and tracking of specific cycle of AE waveforms are used to detect delamination size and location.

  6. Polymers Advance Heat Management Materials for Vehicles

    NASA Technical Reports Server (NTRS)

    2013-01-01

    For 6 years prior to the retirement of the Space Shuttle Program, the shuttles carried an onboard repair kit with a tool for emergency use: two tubes of NOAX, or "good goo," as some people called it. NOAX flew on all 22 flights following the Columbia accident, and was designed to repair damage that occurred on the exterior of the shuttle. Bill McMahon, a structural materials engineer at Marshall Space Flight Center says NASA needed a solution for the widest range of possible damage to the shuttle s exterior thermal protection system. "NASA looked at several options in early 2004 and decided on a sealant. Ultimately, NOAX performed the best and was selected," he says. To prove NOAX would work effectively required hundreds of samples manufactured at Marshall and Johnson, and a concerted effort from various NASA field centers. Johnson Space Center provided programmatic leadership, testing, tools, and crew training; Glenn Research Center provided materials analysis; Langley Research Center provided test support and led an effort to perform large patch repairs; Ames Research Center provided additional testing; and Marshall provided further testing and the site of NOAX manufacturing. Although the sealant never had to be used in an emergency situation, it was tested by astronauts on samples of reinforced carbon-carbon (RCC) during two shuttle missions. (RCC is the thermal material on areas of the shuttle that experience the most heat, such as the nose cone and wing leading edges.) The material handled well on orbit, and tests showed the NOAX patch held up well on RCC.

  7. Mechanisms of double-strand-break repair during gene targeting in mammalian cells.

    PubMed Central

    Ng, P; Baker, M D

    1999-01-01

    In the present study, the mechanism of double-strand-break (DSB) repair during gene targeting at the chromosomal immunoglobulin mu-locus in a murine hybridoma was examined. The gene-targeting assay utilized specially designed insertion vectors genetically marked in the region of homology to the chromosomal mu-locus by six diagnostic restriction enzyme site markers. The restriction enzyme markers permitted the contribution of vector-borne and chromosomal mu-sequences in the recombinant product to be determined. The use of the insertion vectors in conjunction with a plating procedure in which individual integrative homologous recombination events were retained for analysis revealed several important features about the mammalian DSB repair process:The presence of the markers within the region of shared homology did not affect the efficiency of gene targeting.In the majority of recombinants, the vector-borne marker proximal to the DSB was absent, being replaced with the corresponding chromosomal restriction enzyme site. This result is consistent with either formation and repair of a vector-borne gap or an "end" bias in mismatch repair of heteroduplex DNA (hDNA) that favored the chromosomal sequence. Formation of hDNA was frequently associated with gene targeting and, in most cases, began approximately 645 bp from the DSB and could encompass a distance of at least 1469 bp.The hDNA was efficiently repaired prior to DNA replication.The repair of adjacent mismatches in hDNA occurred predominantly on the same strand, suggesting the involvement of a long-patch repair mechanism. PMID:10049929

  8. Lectin-based food poisoning: a new mechanism of protein toxicity.

    PubMed

    Miyake, Katsuya; Tanaka, Toru; McNeil, Paul L

    2007-08-01

    Ingestion of the lectins present in certain improperly cooked vegetables can result in acute GI tract distress, but the mechanism of toxicity is unknown. In vivo, gut epithelial cells are constantly exposed to mechanical and other stresses and consequently individual cells frequently experience plasma membrane disruptions. Repair of these cell surface disruptions allows the wounded cell to survive: failure results in necrotic cell death. Plasma membrane repair is mediated, in part, by an exocytotic event that adds a patch of internal membrane to the defect site. Lectins are known to inhibit exocytosis. We therefore tested the novel hypothesis that lectin toxicity is due to an inhibitory effect on plasma membrane repair. Repair of plasma membrane disruptions and exocytosis of mucus was assessed after treatment of cultured cell models and excised segments of the GI tract with lectins. Plasma membrane disruptions were produced by focal irradiation of individual cells, using a microscope-based laser, or by mechanical abrasion of multiple cells, using a syringe needle. Repair was then assessed by monitoring the cytosolic penetration of dyes incapable of crossing the intact plasma membrane. We found that cell surface-bound lectins potently inhibited plasma membrane repair, and the exocytosis of mucus that normally accompanies the repair response. Lectins potently inhibit plasma membrane repair, and hence are toxic to wounded cells. This represents a novel form of protein-based toxicity, one that, we propose, is the basis of plant lectin food poisoning.

  9. Pulmonary annulus growth after the modified Blalock-Taussig shunt in tetralogy of Fallot.

    PubMed

    Nakashima, Kouki; Itatani, Keiichi; Oka, Norihiko; Kitamura, Tadashi; Horai, Tetsuya; Hari, Yosuke; Miyaji, Kagami

    2014-09-01

    In tetralogy of Fallot (TOF), it is well known that postoperative pulmonary regurgitation reduces right ventricular function during long-term follow-up. Complete repair without a transannular patch should help avoid pulmonary regurgitation. Recently, primary complete repair has been preferred to the staged repair with use of a Blalock-Taussig shunt (BTS) even in neonates or small infants; however, little has been reported about the influence of a BTS on pulmonary annular growth. We examined 40 patients with TOF or double-outlet right ventricle with pulmonary stenosis. Twenty-one patients received a BTS before complete repair, whereas 19 patients underwent primary complete repair. Pulmonary annular size was measured by echocardiography before BTS, complete repair, or both, and ventricular volume was measured by cardiac catheterization. There were no significant differences in complete repair age or body size between the groups. Pulmonary annulus sizes in the BTS group were smaller than those in the primary repair group (Z score, -5.1 ± 2.5 vs -3.7 ± 1.8). After the BTS, significant annular growth (Z score, -2.8 ± 2.1) was observed (p = 0.0028), with a significant increase in left ventricular end-diastolic volume (p = 0.015). When patients with severe pulmonary stenosis (Z score > -7.0) were excluded, pulmonary annular preservation at complete repair was achieved in 64.7% (11/17) of the BTS group and 36.8% (7/19) of the primary repair group (p = 0.088). The BTS increased the pulmonary annular size and the left ventricular volume during the 6 months before complete repair, resulting in preservation of the pulmonary valve function. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Temporal changes in community composition of heterotrophic bacteria during in situ iron enrichment in the western subarctic Pacific (SEEDS-II)

    NASA Astrophysics Data System (ADS)

    Kataoka, Takafumi; Suzuki, Koji; Hayakawa, Maki; Kudo, Isao; Higashi, Seigo; Tsuda, Atsushi

    2009-12-01

    Little is known about the effects of iron enrichment in high-nitrate low-chlorophyll (HNLC) waters on the community composition of heterotrophic bacteria, which are crucial to nutrient recycling and microbial food webs. Using denaturing gradient gel electrophoresis (DGGE) of 16S rDNA fragments, we investigated the heterotrophic eubacterial community composition in surface waters during an in situ iron-enrichment experiment (SEEDS-II) in the western subarctic Pacific in the summer of 2004. DGGE fingerprints representing the community composition of eubacteria differed inside and outside the iron-enriched patch. Sequencing of DGGE bands revealed that at least five phylotypes of α-proteobacteria including Roseobacter, Cytophaga-Flavobacteria- Bacteroides (CFB), γ-proteobacteria, and Actinobacteria occurred in almost all samples from the iron-enriched patch. Diatoms did not bloom during SEEDS-II, but the eubacterial composition in the iron-enriched patch was similar to that in diatom blooms observed previously. Although dissolved organic carbon (DOC) accumulation was not detected in surface waters during SEEDS-II, growth of the Roseobacter clade might have been particularly stimulated after iron additions. Two identified phylotypes of CFB were closely related to the genus Saprospira, whose algicidal activity might degrade the phytoplankton assemblages increased by iron enrichment. These results suggest that the responses of heterotrophic bacteria to iron enrichment could differ among phylotypes during SEEDS-II.

  11. Methods for freeform fabrication of structures

    DOEpatents

    Kaufman, Stephen G.; Spletzer, Barry L.

    2000-01-01

    Rapid prototyping methods and apparatuses that produce structures made of continuous-fiber polymer-matrix composites without the use of molds. Instead of using molds, the composite structure is fabricated patch by patch in layers or wraps, using a two- or three-axis stage connected to a rapidly-reconfigurable forming surface, and a robot arm to position the evolving composite structure, which are both programmable devices. Because programmable devices are included, i.e., a robot and a two- or three-axis stage connected to the reconfigurable forming surface, the control program needed to produce a desired shape can be easily modified to automatically generate the desired shape from an electronic model (e.g., using a CAD/CAM system) of the desired (predetermined) shape.

  12. Repair of Composites: Design Choices Leading to Lower Life-Cycle Cost

    NASA Astrophysics Data System (ADS)

    Kassapoglou, Christos; Rangelov, Konstantin; Rangelov, Svilen

    2017-08-01

    The fabrication cost of composite aircraft structures is revisited and the effect of part size on cost is examined with emphasis on design decisions which affect the ease of (bonded) repair and the total cost of the part and subsequent repairs. The case of moderately loaded stiffened fuselage or wing panels under compression is analysed in detail and the fabrication cost of the panel made as a single piece or as an assembly of smaller identical components or modules is determined. The cost of special purpose repairs for two different damage sizes is compared to removing and replacing damaged modules. Hand layup and automated processing are compared. It is found that for certain repair sizes removing and replacing modules leads to lower overall cost as compared to applying a special purpose repair.

  13. Surgical results and protocols in the spectrum of tetralogy of Fallot.

    PubMed Central

    Kirklin, J W; Blackstone, E H; Kirklin, J K; Pacifico, A D; Aramendi, J; Bargeron, L M

    1983-01-01

    Between 1967 and July 1982, 1103 operations were performed for the tetralogy of Fallot of all types with 116 (10.5%) hospital deaths. Eighty-eight hospital deaths (10.5%) occurred in the 836 patients undergoing repair. The incremental risk factors for hospital death after repair include pulmonary arterial problems (p = 0.0002), major associated cardiac anomalies (p less than 0.0001), small size (young age) (p less than 0.0001), and more than one previous operation (p = 0.0004). Absent pulmonary valve is a risk factor (p = 0.04). In patients with pulmonary stenosis, the hospital mortality has decreased with time (p = 0.08), but the incremental risk of a high hematocrit (p = 0.0003) and of transannular patching (p = 0.05) has persisted. In the current era, the risk of repair in patients with pulmonary stenosis is estimated to be 1.6% (70% confidence limits [CL] 0.7% to 3.5%) at age 5 years, and at age 12 months to be 4.1% (CL 2.7% to 6.3%) without a transannular patch and 7.7% (CL a5.3% to 11%) with one. When pulmonary atresia is present, the probability of hospital death after repair when a valved extracardiac conduit is used is estimated to be lowest (5%; CL 2% to 8%) between 5 1/2 and 16 years of age. No deaths occurred among 53 patients with pulmonary stenosis receiving a primary palliative Blalock-Taussig or Gore-Tex shunt, and six deaths (12%) occurred in 51 patients with pulmonary atresia. Serious interim complications (sudden death, brain abscess) after these shunts occurred in two (1.9%; CL 0.6% to 4.5%) of the patients operated on. No iatrogenic pulmonary arterial problems have been recognized. Protocols based on these results are presented. Many of these selective recommendations may become unnecessary if the damaging effects of cardiopulmonary bypass are overcome by future research. Images Fig. 2. Fig. 3. PMID:6615049

  14. Glaucoma aqueous drainage device erosion repair with buccal mucous membrane grafts.

    PubMed

    Rootman, Dan B; Trope, Graham E; Rootman, David S

    2009-01-01

    Glaucoma aqueous drainage devices are important and effective in the management of recalcitrant glaucoma. One complication of this procedure is erosion and exposure of the tube or plate. Strategies to re-cover glaucoma aqueous drainage devices in such cases have met with variable success. The majority of these interventions use conjunctiva for superficial coverage. However, conjunctiva can be in limited supply, and subject to reerosion. In this report, we discuss the use of oral buccal mucous membrane in combination with a lamellar corneal patch graft for repair of 3 exposed tubes, 2 plates, and a pars plana clip. Mean time to exposure was 4.8 years. Five eyes from 4 patients are presented and the surgical technique is described. Buccal membrane repairs were considered a surgical success in 5 out of 6 cases (83%) with mean follow-up of 1.5 years. We advocate the use of buccal membrane in the repair of glaucoma aqueous drainage device tube/plate erosions in patients for whom local conjunctiva is of variable quality or limited supply. Advantages of this procedure and tissue option are discussed.

  15. Iatrogenic Diversion of Inferior Vena Cava into Left Atrium after Surgery for a Rare Combination of Congenital Heart Diseases

    PubMed Central

    Sabzi, Feridoun

    2016-01-01

    Atrial septal defect (ASD) is a common congenital anomaly that has low surgical mortality and morbidity. We report a very rare case of a low-lying ASD, combined with the drainage of the inferior vena cava and the left superior vena cava into the left atrium. This combination was associated with an unroofed coronary sinus. We also describe an iatrogenic surgical diversion of the inferior vena cava into the left atrium with its complication. The patient presented with moderate cyanosis and was referred for elective ASD repair. He underwent surgical repair of the ASD after transthoracic echocardiography. Early postoperative right-to-left shunting with cyanosis and hypoxia was associated with abdominal complications. Surgical re-exploration revealed the diversion of the inferior vena cava into the left atrium, which was repaired with a pericardial patch. Peptic ulcer perforation was repaired after abdominal laparotomy. The patient had an uneventful recovery and was discharged home on the 17th postoperative day. One-year follow-up revealed no recurrence of cyanosis or residual ASD on echocardiography. PMID:27928261

  16. Optical trapping performance of dielectric-metallic patchy particles

    PubMed Central

    Lawson, Joseph L.; Jenness, Nathan J.; Clark, Robert L.

    2015-01-01

    We demonstrate a series of simulation experiments examining the optical trapping behavior of composite micro-particles consisting of a small metallic patch on a spherical dielectric bead. A full parameter space of patch shapes, based on current state of the art manufacturing techniques, and optical properties of the metallic film stack is examined. Stable trapping locations and optical trap stiffness of these particles are determined based on the particle design and potential particle design optimizations are discussed. A final test is performed examining the ability to incorporate these composite particles with standard optical trap metrology technologies. PMID:26832054

  17. Computer generated holographic microtags

    DOEpatents

    Sweatt, W.C.

    1998-03-17

    A microlithographic tag comprising an array of individual computer generated holographic patches having feature sizes between 250 and 75 nanometers is disclosed. The tag is a composite hologram made up of the individual holographic patches and contains identifying information when read out with a laser of the proper wavelength and at the proper angles of probing and reading. The patches are fabricated in a steep angle Littrow readout geometry to maximize returns in the -1 diffracted order. The tags are useful as anti-counterfeiting markers because of the extreme difficulty in reproducing them. 5 figs.

  18. Structural attributes of individual trees for identifying homogeneous patches in a tropical rainforest

    NASA Astrophysics Data System (ADS)

    Alexander, Cici; Korstjens, Amanda H.; Hill, Ross A.

    2017-03-01

    Mapping and monitoring tropical rainforests and quantifying their carbon stocks are important, both for devising strategies for their conservation and mitigating the effects of climate change. Airborne Laser Scanning (ALS) has advantages over other remote sensing techniques for describing the three-dimensional structure of forests. This study identifies forest patches using ALS-based structural attributes in a tropical rainforest in Sumatra, Indonesia. A method to group trees with similar attributes into forest patches based on Thiessen polygons and k-medoids clustering is developed, combining the advantages of both raster and individual tree-based methods. The structural composition of the patches could be an indicator of habitat type and quality. The patches could also be a basis for developing allometric models for more accurate estimation of carbon stock than is currently possible with generalised models.

  19. Evaluation of bisphenol E cyanate ester for the resin-injection repair of advanced composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lio, Wilber Yaote

    2009-12-01

    This thesis is a compilation of a general introduction and literature review that ties together the subsequent chapters which consist of two journal articles that have yet to be submitted for publication. The overall topic relates to the evaluation and application of a new class of cyanate ester resin with unique properties that lend it applicable to use as a resin for injection repair of high glass transition temperature polymer matrix composites. The first article (Chapter 2) details the evaluation and optimization of adhesive properties of this cyanate ester and alumina nanocomposites under different conditions. The second article (Chapter 3)more » describes the development and evaluation of an injection repair system for repairing delaminations in polymer matrix composites.« less

  20. Dynamics in species composition of stream fish assemblages: environmental variability and nested subsets

    Treesearch

    Christopher M. Taylor; Melvin L. Warren

    2001-01-01

    Stream landscapes are highly variable in space and time and, like terrestrial landscapes, the resources they contain are patchily distributed. Organisms may disperse among patches to fulfill life-history requirements, but biotic and abiotic factors may limit patch or locality occupancy. Thus, the dynamics of immigration and extinction determine, in part, the local...

  1. The effects of matrix structure on movement decisions of meadow voles (Microtus pennsylvanicus)

    Treesearch

    Robin E. Russell; Robert K. Swihart; Bruce A. Craig

    2007-01-01

    The composition of the landscape between patches (the matrix) can have important effects on movement rates that potentially outweigh the effects of patch size and isolation. We conducted a small-scale experiment with radiocollared meadow voles (Microtus pennsylvanicus) to quantify the effects of matrix habitat on movement behavior of voles. Habitat...

  2. [Treatment of Fallot tetralogy with a transannular patch. Six years follow-up].

    PubMed

    Galicia-Tornell, Myriam; Reyes-López, Alfonso; Ruíz-González, Sergio; Bolio-Cerdán, Alejandro; González-Ojeda, Alejandro; Fuentes-Orozco, Clotilde

    2015-01-01

    Primary repair of Fallot tetralogy has been performed successfully for the last 45 years. It has low surgical mortality (< 5%), with excellent long-term results. However, there are delayed adverse effects: progressive right ventricular dilation and dysfunction, arrhythmia, and sudden death. In our centre, Fallot tetralogy is the most common form of cyanotic congenital heart disease (including transannular patch) and accounts for 7.5% of all cardiovascular surgical procedures. The mid-term follow-up results are reported. Case series. The study included patients who had complete repair of Fallot tetralogy with transannular patch from January 2000 to December 2009. An analysis was performed on the clinical variables, morbidity and mortality. There were 52 patients in the study, with mean age 4 ± 2 years. Perioperative mortality in 6 patients, with 5 associated with residual right ventricular obstruction and, 1 associated with further surgery. The survival rate was 88% (46) patients, with a follow-up 75 ± 26 months. Late morbidity occurred in 14, due to right ventricular dysfunction in 11, recurrent distal obstruction in 2, and residual ventricular septal defect in 1. Associated risk factors were severe pulmonary insufficiency (p=0.001); QRS > 160 ms, p=0.001); cardiothoracic > 0.60 index, (p=0.048), and tricuspid regurgitation (p=0.001). There was reasonable long-term survival and excellent quality of life after total correction of Fallot tetralogy; however, progressive right ventricular dysfunction requires continuous monitoring, as well as the choice of optimal timing of pulmonary valve replacement. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  3. Design and Analysis of a Stiffened Composite Structure Repair Concept

    NASA Technical Reports Server (NTRS)

    Przekop, Adam

    2011-01-01

    A design and analysis of a repair concept applicable to a stiffened thin-skin composite panel based on the Pultruded Rod Stitched Efficient Unitized Structure is presented. Since the repair concept is a bolted repair using metal components, it can easily be applied in the operational environment. Initial analyses are aimed at validating the finite element modeling approach by comparing with available test data. Once confidence in the analysis approach is established several repair configurations are explored and the most efficient one presented. Repairs involving damage to the top of the stiffener alone are considered in addition to repairs involving a damaged stiffener, flange and underlying skin. High fidelity finite element modeling techniques such as mesh-independent definition of compliant fasteners, elastic-plastic metallic material properties and geometrically nonlinear analysis are utilized in the effort. The results of the analysis are presented and factors influencing the design are assessed and discussed.

  4. Evaluation of a new composite prosthesis for the repair of abdominal wall defects.

    PubMed

    Losi, Paola; Munaò, Antonella; Spiller, Dario; Briganti, Enrica; Martinelli, Ilaria; Scoccianti, Marco; Soldani, Giorgio

    2007-10-01

    The degree of integration of biomaterials used in the repair of abdominal wall defects seems to depend upon the structure of the prosthesis. The present investigation evaluates the behaviour in terms of adhesion formation and integration of a new composite prosthesis that could be employed in this clinical application. Full-thickness abdominal wall defects (7 x 5 cm) were created in 16 anaesthetized New Zealand white rabbits and the prosthesis were placed in direct contact with the visceral peritoneum during the experiment. The defects were repaired with a composite prosthesis or pure polypropylene mesh to establish two study groups (n = 8 each). The composite device was constituted by a polypropylene mesh physically attached to a poly(ether)urethane-polydimethylsiloxane laminar sheet. Animals were sacrificed 7, 14, 21 and 30 days after implant and prosthesis/surrounding tissue specimens subjected to light and electron microscopy. Firm adhesions were detected in the polypropylene implants, while they were not present in the composite implants. The excellent behaviour of the composite prosthesis shown in this study warrants further investigation on its use for the repair of abdominal wall defects when a prosthetic device needs to be placed in contact with the intestinal loops.

  5. Repair of restorations--criteria for decision making and clinical recommendations.

    PubMed

    Hickel, Reinhard; Brüshaver, Katrin; Ilie, Nicoleta

    2013-01-01

    In the last decade, repair of restorations has become more and more popular while teaching repair of restorations is now included in most universities in Europe and North America. The aim of this paper was therefore to systematically review the clinical and the in vitro aspects of repair of restorations by considering different restorative materials--resin-based composites, amalgam, glass-ionomer cements, ceramics or metals. The paper gives also an overview of the occurrences of teaching repair in different universities. Furthermore, the paper outlines criteria for decision making when to treat a defect restoration with refurbishment, repair, replacement or no treatment. The database search strategy for resin based composite restoration repair (n=360) and the following hand search (n=95) retrieved 455 potentially eligible studies. After de-duplication, 260 records were examined by the titles and abstracts. 154 studies were excluded and 106 articles were assessed for eligibility by analyzing the full texts. Following the same search and selection process, 42 studies for amalgam repair, 51 studies for cast, inlay or porcelain restoration repair and 8 studies for teaching were assessed for eligibility by analysis of the full texts. Following databases were analyzed: Cochrane Library, MEDLINE, EMBASE, BIOSIS and PUBMED. Papers were selected if they met the following criteria: replacement, refurbishment or repair of resin composite restorations or amalgam restorations or inlay, cast restoration or porcelain repair. Clinical studies, in vitro studies and reports about teaching were included. Repair of restoration is a valuable method to improve the quality of restorations and is accepted, practiced and taught in many universities. However, there is a need for methodologically sound randomized controlled long-term clinical trials to be able to give an evidence based recommendation. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. Repair & Strengthening of Distressed/Damaged Ends of Prestressed Beams with FRP Composites

    DOT National Transportation Integrated Search

    2018-02-01

    Over the past few decades, fiber reinforced polymer (FRP) composites have emerged as a lightweight and efficient material used for the repair and retrofit of concrete infrastructures. FRP can be applied to concrete as either externally bonded laminat...

  7. INTERNAL REPAIR OF PIPELINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robin Gordon; Bill Bruce; Ian Harris

    2004-04-12

    The two broad categories of deposited weld metal repair and fiber-reinforced composite liner repair technologies were reviewed for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Preliminary test programs were developed for both deposited weld metal repair and for fiber-reinforced composite liner repair. Evaluation trials have been conducted using a modified fiber-reinforced composite liner provided by RolaTube and pipe sections without liners. All pipe section specimens failed in areas of simulated damage. Pipe sections containing fiber-reinforcedmore » composite liners failed at pressures marginally greater than the pipe sections without liners. The next step is to evaluate a liner material with a modulus of elasticity approximately 95% of the modulus of elasticity for steel. Preliminary welding parameters were developed for deposited weld metal repair in preparation of the receipt of Pacific Gas & Electric's internal pipeline welding repair system (that was designed specifically for 559 mm (22 in.) diameter pipe) and the receipt of 559 mm (22 in.) pipe sections from Panhandle Eastern. The next steps are to transfer welding parameters to the PG&E system and to pressure test repaired pipe sections to failure. A survey of pipeline operators was conducted to better understand the needs and performance requirements of the natural gas transmission industry regarding internal repair. Completed surveys contained the following principal conclusions: (1) Use of internal weld repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling (HDD) when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) Pipe diameter sizes range from 50.8 mm (2 in.) through 1,219.2 mm (48 in.). The most common size range for 80% to 90% of operators surveyed is 508 mm to 762 mm (20 in. to 30 in.), with 95% using 558.8 mm (22 in.) pipe. An evaluation of potential repair methods clearly indicates that the project should continue to focus on the development of a repair process involving the use of GMAW welding and on the development of a repair process involving the use of fiber-reinforced composite liners.« less

  8. Immediate vs delayed repair bond strength of a nanohybrid resin composite.

    PubMed

    El-Askary, Farid S; El-Banna, Ahmed H; van Noort, Richard

    2012-06-01

    To evaluate both the immediate and water-stored repair tensile bond strength (TBS) of a nanohybrid resin composite using different bonding protocols. One hundred sixty half hourglass-shaped slabs were prepared. Eighty half-slabs were wet ground immediately after light curing using high-speed abrasive burs, while the other half-slabs were stored in water for one month (delayed) and then wet ground for repair. Each set of the 80 repaired slabs was split into two groups to be tested for TBS after 24 h or 1 month of water storage. For all repaired slabs, either immediate or delayed, four bonding procedures were used involving wet and dry bonding with a 3-step etch-and-rinse adhesive with or without silane pretreatment. TBS tests were performed at a crosshead speed of 0.5 mm/min. To determine the cohesive strength of the resin composite itself, which served as the reference, additional whole slabs were prepared and tested in tension after a 24-h (n = 10) and a 1-month storage period (n = 10). Failure modes were evaluated using a stereomicroscope at 40X magnification. Three-way ANOVA was run to test the effect of water storage, testing time, bonding protocols, and their interactions on the repair TBS, which was given as a percentage of the reference values. For the immediate repair groups, the repair TBS ranged from 40% to 61.9% after 24-h storage and from 26% to 53.1% after 1-month water storage compared to the TBS of the whole slabs. For the delayed repair group, the repaired TBS ranged from 47.2% to 63.6% for the 24-h repairs and from 32.2% to 44.2% for the test groups stored in water for 1 month. Three-way ANOVA revealed that water storage had no significant effect on the repair TBS (p = 0.619). Both testing time and bonding protocols had a significant effect on the repair TBS (p = 0.001). The interactions between the independent variables (water storage, testing time, and bonding protocols) had no significant effect (p = 0.067). The repair bond strength was consistently and highly significantly less than the cohesive strength of the composite. A delay of 1 month before carrying out the repair had no effect on the bond strength, irrespective of the bonding procedure used. Silane treatment did not improve the repair bond strength. In all instances, except for the immediate wet bonding plus silane procedure and delayed dry bonding, the bond strength of the repairs significantly dropped after 1 month of storage in water.

  9. Repair bond strength of nanohybrid composite resins with a universal adhesive

    PubMed Central

    Altinci, Pinar; Mutluay, Murat; Tezvergil-Mutluay, Arzu

    2018-01-01

    Abstract Objective: To investigate the repair bond strength of fresh and aged nanohybrid and hybrid composite resins using a universal adhesive (UA). Materials and methods: Fresh and aged substrates were prepared using two nanohybrid (Venus Pearl, Heraus Kulzer; Filtek Supreme XTE, 3 M ESPE) and one hybrid (Z100, 3 M ESPE) composite resin, and randomly assigned to different surface treatments: (1) no treatment (control), (2) surface roughening with 320-grit (SR), (3) SR + UA (iBOND, Heraus Kulzer), (4) SR + Silane (Signum, Ceramic Bond I, Heraeus Kulzer) + UA, (5) SR + Sandblasting (CoJet, 3 M ESPE) + Silane + UA. After surface treatment, fresh composite resin was added to the substrates at 2 mm layer increments to a height of 5 mm, and light cured. Restored specimens were water-stored for 24 h and sectioned to obtain 1.0 × 1.0 mm beams (n = 12), and were either water-stored for 24 h at 37 °C, or water-stored for 24 h, and then thermocycled for 6000 cycles before microtensile bond strength (µTBS) testing. Data were analyzed with ANOVA and Tukey’s HSD tests (p = .05). Results: Combined treatment of SR, sandblasting, silane and UA provided repair bond strength values comparable to the cohesive strength of each tested resin material (p < .05). Thermocycling significantly reduced the cohesive strength of the composite resins upto 65% (p < .05). Repair bond strengths of UA-treated groups were more stable under thermocycling. Conclusions: Universal adhesive application is a reliable method for composite repair. Sandblasting and silane application slightly increases the repair strength for all substrate types. PMID:29250576

  10. Repair bond strength of nanohybrid composite resins with a universal adhesive.

    PubMed

    Altinci, Pinar; Mutluay, Murat; Tezvergil-Mutluay, Arzu

    2018-01-01

    Objective: To investigate the repair bond strength of fresh and aged nanohybrid and hybrid composite resins using a universal adhesive (UA). Materials and methods: Fresh and aged substrates were prepared using two nanohybrid (Venus Pearl, Heraus Kulzer; Filtek Supreme XTE, 3 M ESPE) and one hybrid (Z100, 3 M ESPE) composite resin, and randomly assigned to different surface treatments: (1) no treatment (control), (2) surface roughening with 320-grit (SR), (3) SR + UA (iBOND, Heraus Kulzer), (4) SR + Silane (Signum, Ceramic Bond I, Heraeus Kulzer) + UA, (5) SR + Sandblasting (CoJet, 3 M ESPE) + Silane + UA. After surface treatment, fresh composite resin was added to the substrates at 2 mm layer increments to a height of 5 mm, and light cured. Restored specimens were water-stored for 24 h and sectioned to obtain 1.0 × 1.0 mm beams ( n  = 12), and were either water-stored for 24 h at 37 °C, or water-stored for 24 h, and then thermocycled for 6000 cycles before microtensile bond strength (µTBS) testing. Data were analyzed with ANOVA and Tukey's HSD tests ( p  = .05). Results: Combined treatment of SR, sandblasting, silane and UA provided repair bond strength values comparable to the cohesive strength of each tested resin material ( p  < .05). Thermocycling significantly reduced the cohesive strength of the composite resins upto 65% ( p  < .05). Repair bond strengths of UA-treated groups were more stable under thermocycling. Conclusions: Universal adhesive application is a reliable method for composite repair. Sandblasting and silane application slightly increases the repair strength for all substrate types.

  11. Surgical repair and postoperative course of an infant with infracardiac total anomalous pulmonary venous connection, cor triatriatum sinistrum and transposition of the great arteries.

    PubMed

    Thies, W R; Matthies, W; Minami, K; Pott, U; Meyer, H; Körfer, R

    1990-01-01

    The combination of a d-transposition of the great arteries, cor triatriatum sinistrum and a total anomalous pulmonary venous connection of the infracardiac type is a very rare condition. Up to now, one surgical repair in an adolescent with transposed great arteries and total anomalous pulmonary venous drainage of the supracardiac type has been reported. In this paper, an infant with the above mentioned cardiovascular malformation is presented. The common pulmonary vein drained into the inferior vena cava and was obstructed. There were arborisation abnormalities in both lungs with mild pulmonary hypertension. The infant has been successfully operated upon at the age of 6 months and a weight of 4.5 kg. The membrane within the left atrium was resected, the common pulmonary vein was anastomosed to the left atrium and a Mustard procedure was performed. During the first 6 postoperative weeks, the infant had problems with adaptation. There was both a transient ballooning of the Mustard patch with significant obstruction of the pulmonary venous drainage and a delayed pulmonary recovery. Two months later, the patch was straightened and the child could be discharged from hospital. After 12 months, the child died from an infection of the airways.

  12. Management and outcomes of scoliosis in children with congenital diaphragmatic hernia.

    PubMed

    Antiel, Ryan M; Riley, John S; Cahill, Patrick J; Campbell, Robert M; Waqar, Lindsay; Herkert, Lisa M; Rintoul, Natalie E; Peranteau, William H; Flake, Alan W; Adzick, N Scott; Hedrick, Holly L

    2016-12-01

    The purpose of this study was to evaluate the management and outcomes of CDH patients with scoliosis. From January 1996 to August 2015, 26 of 380 (7%) CDH patients were diagnosed with scoliosis. Six (23%) were prenatally diagnosed by ultrasound, and 9 (35%) were diagnosed postnatally. The remaining 11 (42%) developed scoliosis after discharge. Mean follow-up was 6.6years. Among the 15 patients with congenital scoliosis, there were 2 (13%) perinatal deaths. Five of the 13 (38%) survivors required orthopedic surgery, and 2 have required bracing. The mean age at initial surgery was 7years. These five children underwent an average of 2.8 (range 1-7) expansions or revisions. All surgical patients required supplemental oxygen at 28days of life, and 1 required a tracheostomy. None of the 11 patients who developed scoliosis later in life required surgery, but 3 have required bracing. Six of the 11 (55%) required a patch repair for CDH compared to 158 of 264 (60%) CDH patients without scoliosis (p=0.73). Early diagnosis of scoliosis in CDH patients is associated with a high rate of surgery. There was not a higher incidence of patch repair among patients who developed scoliosis. Prognosis. Retrospective study, level II. Copyright © 2016. Published by Elsevier Inc.

  13. Evaluation of flexural, diametral tensile, and shear bond strength of composite repairs.

    PubMed

    Imbery, T A; Gray, T; DeLatour, F; Boxx, C; Best, A M; Moon, P C

    2014-01-01

    Repairing composite restorations may be a more conservative treatment than replacing the entire restoration. The objective of this in vitro study was to determine the best repair method by measuring flexural, diametral tensile, and shear bond strength of repaired composites in which the surfaces were treated with chemical primers (Add & Bond or Silane Bond Enhancer), a bonding agent (Optibond Solo Plus [OBSP]), or mechanical retention with a bonding agent. Filtek Supreme Ultra shade B1B was placed in special molds to fabricate specimens that served to test the flexural, diametral tensile, or shear strength of the inherent resin substrate. The same molds were modified to make specimens for testing repair strength of the resin. Repairs were made immediately or after aging in deionized water at 37°C for seven days. All repair sites were finished with coarse Sof-Lex discs to simulate finishing new restorations or partially removing aged restorations. Repair surfaces were treated with one of the following: 1) phosphoric-acid etching and OBSP; 2) Add & Bond; 3) phosphoric-acid etching, Silane Bond Enhancer, and OBSP; or 4) quarter round bur, phosphoric-acid etching, and OBSP. Specimens were placed back in the original molds to fabricate specimens for diametral tensile or flexural testing or in an Ultradent jig to make specimens for shear bond testing. Composite resin in shade B5B was polymerized against the treated surfaces to make repairs. Two negative control groups for the three testing methods consisted of specimens in which repairs were made immediately or after aging without any surface treatments. Controls and experimental repairs were aged (water 37°C, 24 hours) before flexural, diametral tensile, or shear testing in an Instron Universal testing machine at a crosshead speed of 0.5 mm/min. Experimental flexural repair strengths ranged from 26.4% to 88.6% of the inherent substrate strength. Diametral tensile repair strengths ranged from 40% to 80% of the inherent substrate strength, and shear bond strength repairs ranged from 56% to 102%. Geometric means were statistically analyzed with two-way analysis of variance on their log-transformed values. Significant differences were determined using Tukey honestly significant difference (p<0.05). Depending on the mechanical property being tested, surface treatments produced different results. OBSP produced more consistent results than chemical primers.

  14. Tensile bond strength of an aged resin composite repaired with different protocols.

    PubMed

    Celik, Esra Uzer; Ergücü, Zeynep; Türkün, L Sebnem; Ercan, Utku Kürșat

    2011-08-01

    To evaluate the effect of different surface treatments and bonding procedures on the tensile bond strength (TBS) of resin composites repaired 6 months after polymerization. Resin composite sticks were aged in distilled water at 37°C for 6 months. They were divided into 12 groups (n = 10) according to the combination of surface treatment/bonding procedures [none, only bur treatment, XP Bond (XPB/Dentsply/DeTrey) with/without bur, AdheSE (A-SE/Ivoclar/Vivadent) with/without bur, Composite Primer (CP/GC) with/without bur, CP after bur and acid-etching, XPB after acid etching and CP with bur, A-SE after bur and CP]. The ultimate tensile bond strength (UTS) of the resin composites was tested in intact but aged specimens. Tensile bond strengths were tested with a universal testing machine (Shimadzu). Data were analyzed using one-way ANOVA and Duncan Multiple Comparisons tests (p < 0.05). All repaired groups showed significantly higher TBS than the group without any sureface treatment (p < 0.05). Four groups resulted in TBS similar to those of intact resin composite UTS: A-SE, A-SE with bur, A-SE after CP with bur, and XPB after acid etching+CP with bur. Bur treatment, silane primer or etch-and-rinse adhesive application alone were not successful in the repair process of aged resin composite, whereas self-etching adhesive alone showed similar performance to the intact specimens. Combined procedures generally showed better performance: A-SE with bur, A-SE after CP with bur, and XPB after acid etching +CP with bur showed TBS similar to those of the intact specimens. It was concluded that bur roughening of the surfaces and rebonding procedures were essential for repairing aged resin composites.

  15. Anthropogenic Halo Disturbances Alter Landscape and Plant Richness: A Ripple Effect

    PubMed Central

    Liu, Bingliang; Su, Jinbao; Chen, Jianwei; Cui, Guofa; Ma, Jianzhang

    2013-01-01

    Although anthropogenic landscape fragmentation is often considered as the primary threat to biodiversity, other factors such as immediate human disturbances may also simultaneously threaten species persistence in various ways. In this paper, we introduce a conceptual framework applied to recreation landscapes (RLs), with an aim to provide insight into the composite influences of landscape alteration accompanying immediate human disturbances on plant richness dynamics. These impacts largely occur at patch-edges. They can not only alter patch-edge structure and environment, but also permeate into surrounding natural matrices/patches affecting species persistence–here we term these “Halo disturbance effects” (HDEs). We categorized species into groups based on seed or pollen dispersal mode (animal- vs. wind-dispersed) as they can be associated with species richness dynamics. We evaluated the richness of the two groups and total species in our experimental landscapes by considering the distance from patch-edge, the size of RLs and the intensity of human use over a six-year period. Our results show that animal-dispersed species decreased considerably, whereas wind-dispersed species increased while their richness presented diverse dynamics at different distances from patch-edges. Our findings clearly demonstrate that anthropogenic HDEs produce ripple effects on plant, providing an experimental interpretation for the diverse responses of species to anthropogenic disturbances. This study highlights the importance of incorporating these composite threats into conservation and management strategies. PMID:23424648

  16. Finite-Element Analysis of Crack Arrest Properties of Fiber Reinforced Composites Application in Semi-Elliptical Cracked Pipelines

    NASA Astrophysics Data System (ADS)

    Wang, Linyuan; Song, Shulei; Deng, Hongbo; Zhong, Kai

    2018-04-01

    In nowadays, repair method using fiber reinforced composites as the mainstream pipe repair technology, it can provide security for X100 high-grade steel energy long-distance pipelines in engineering. In this paper, analysis of cracked X100 high-grade steel pipe was conducted, simulation analysis was made on structure of pipes and crack arresters (CAs) to obtain the J-integral value in virtue of ANSYS Workbench finite element software and evaluation on crack arrest effects was done through measured elastic-plastic fracture mechanics parameter J-integral and the crack arrest coefficient K, in a bid to summarize effect laws of composite CAs and size of pipes and cracks for repairing CAs. The results indicate that the K value is correlated with laying angle λ, laying length L2/D1, laying thickness T1/T2of CAs, crack depth c/T1 and crack length a/c, and calculate recommended parameters for repairing fiber reinforced composite CAs in terms of two different crack forms.

  17. Landscape-level effects on aboveground biomass of tropical forests: A conceptual framework.

    PubMed

    Melito, Melina; Metzger, Jean Paul; de Oliveira, Alexandre A

    2018-02-01

    Despite the general recognition that fragmentation can reduce forest biomass through edge effects, a systematic review of the literature does not reveal a clear role of edges in modulating biomass loss. Additionally, the edge effects appear to be constrained by matrix type, suggesting that landscape composition has an influence on biomass stocks. The lack of empirical evidence of pervasive edge-related biomass losses across tropical forests highlights the necessity for a general framework linking landscape structure with aboveground biomass. Here, we propose a conceptual model in which landscape composition and configuration mediate the magnitude of edge effects and seed-flux among forest patches, which ultimately has an influence on biomass. Our model hypothesizes that a rapid reduction of biomass can occur below a threshold of forest cover loss. Just below this threshold, we predict that changes in landscape configuration can strongly influence the patch's isolation, thus enhancing biomass loss. Moreover, we expect a synergism between landscape composition and patch attributes, where matrix type mediates the effects of edges on species decline, particularly for shade-tolerant species. To test our conceptual framework, we propose a sampling protocol where the effects of edges, forest amount, forest isolation, fragment size, and matrix type on biomass stocks can be assessed both collectively and individually. The proposed model unifies the combined effects of landscape and patch structure on biomass into a single framework, providing a new set of main drivers of biomass loss in human-modified landscapes. We argue that carbon trading agendas (e.g., REDD+) and carbon-conservation initiatives must go beyond the effects of forest loss and edges on biomass, considering the whole set of effects on biomass related to changes in landscape composition and configuration. © 2017 John Wiley & Sons Ltd.

  18. Understanding Magnetic Resonance Imaging of Knee Cartilage Repair: A Focus on Clinical Relevance.

    PubMed

    Hayashi, Daichi; Li, Xinning; Murakami, Akira M; Roemer, Frank W; Trattnig, Siegfried; Guermazi, Ali

    2017-06-01

    The aims of this review article are (a) to describe the principles of morphologic and compositional magnetic resonance imaging (MRI) techniques relevant for the imaging of knee cartilage repair surgery and their application to longitudinal studies and (b) to illustrate the clinical relevance of pre- and postsurgical MRI with correlation to intraoperative images. First, MRI sequences that can be applied for imaging of cartilage repair tissue in the knee are described, focusing on comparison of 2D and 3D fast spin echo and gradient recalled echo sequences. Imaging features of cartilage repair tissue are then discussed, including conventional (morphologic) MRI and compositional MRI techniques. More specifically, imaging techniques for specific cartilage repair surgery techniques as described above, as well as MRI-based semiquantitative scoring systems for the knee cartilage repair tissue-MR Observation of Cartilage Repair Tissue and Cartilage Repair OA Knee Score-are explained. Then, currently available surgical techniques are reviewed, including marrow stimulation, osteochondral autograft, osteochondral allograft, particulate cartilage allograft, autologous chondrocyte implantation, and others. Finally, ongoing research efforts and future direction of cartilage repair tissue imaging are discussed.

  19. [Hybrid repair of postoperative ventral hernia].

    PubMed

    Gogiya, B Sh; Alyautdinov, R R; Karmazanovsky, G G; Chekmareva, I A; Kopyltsov, A A

    2018-01-01

    To develop new technique of abdominal wall repair for postoperative ventral hernia without disadvantages which are intrinsic for open and laparoscopic surgery. Combined open and laparoscopic hernia repair was used in 18 patients with postoperative ventral hernia. Open stage provided safe dissection of abdominal adhesions and defect closure by autoplasty, laparoscopic procedure consisted of prosthesis deployment without separation of abdominal wall layers. Two types of composite endoprostheses with anti-adhesive coating were used for abdominal wall repair. There were no cases of recurrence or infectious complications in long-term period (from 3 to 106 months). Hybrid repair of postoperative ventral hernia is safe and effective procedure. Further studies are necessary to assess cost-effectiveness ratio of this method in view of expensive composite endoprostheses and laparoscopic supplies.

  20. Fatigue Resistance of Liquid-assisted Self-repairing Aluminum Alloys Reinforced with Shape Memory Alloys

    NASA Technical Reports Server (NTRS)

    Wright, M. Clara; Manuel, Michele; Wallace, Terryl

    2013-01-01

    A self-repairing aluminum-based composite system has been developed using a liquid-assisted healing theory in conjunction with the shape memory effect of wire reinforcements. The metal-metal composite was thermodynamically designed to have a matrix with a relatively even dispersion of a low-melting eutectic phase, allowing for repair of cracks at a predetermined temperature. Additionally, shape memory alloy (SMA) wire reinforcements were used within the composite to provide crack closure. Investigators focused the research on fatigue cracks propagating through the matrix in order to show a proof-of-concept Shape Memory Alloy Self-Healing (SMASH) technology for aeronautical applications.

  1. Effect of Diamond Bur Grit Size on Composite Repair.

    PubMed

    Valente, Lisia L; Silva, Manuela F; Fonseca, Andrea S; Münchow, Eliseu A; Isolan, Cristina P; Moraes, Rafael R

    2015-06-01

    This study investigated the effect of diamond bur grit size on the repair bond strength of fresh and aged resin composites. Blocks of microhybrid composite (Opallis, FGM) were stored in distilled water at 37°C for 24 h (fresh composite) or subjected to 5000 thermal cycles (aged composite). The surfaces were roughened using diamond-coated, flame-shaped carbide burs with medium grit (#3168), fine grit (#3168F), or extra-fine grit (#3168FF). The control group underwent no surface treatment. Surface roughness, water contact angle, and surface topography by scanning electron microscopy (SEM) were evaluated (n = 3). Samples were restored with resin composite and sectioned into beam-shaped specimens, which were subjected to microtensile bond testing. Failure modes were classified using a stereomicroscope. Data were statistically analyzed using the Student- Newman-Keuls test and two-way ANOVA, with significance set at p < 0.05. Higher surface roughness was observed for groups treated with the medium- and fine-grit burs; aged composites were rougher than fresh composites. The water contact angle formed on the aged composite was lower than that on the fresh composite. The highest repair bond strength was observed for the fine-grit bur group, and the lowest was recorded for control. Interfacial failures were more predominant. SEM images showed that the surfaces treated with fine- and extra-fine-grit burs had a more irregular topography. Surface roughening of fresh or aged resin composites with diamond burs improved retention of the repair material. Fine-grit burs generally performed better than medium- and extra-fine-grit burs.

  2. Circularly Polarized S Band Dual Frequency Square Patch Antenna Using Glass Microfiber Reinforced PTFE Composite

    PubMed Central

    Samsuzzaman, M.; Islam, M. T.; Arshad, Haslina; Mandeep, J. S.; Misran, N.

    2014-01-01

    Circularly polarized (CP) dual frequency cross-shaped slotted patch antenna on 1.575 mm thick glass microfiber reinforced polytetrafluoroethylene (PTFE) composite material substrate is designed and fabricated for satellite applications. Asymmetric cross-shaped slots are embedded in the middle of the square patch for CP radiation and four hexagonal slots are etched on the four sides of the square patch for desired dual frequency. Different substrate materials have been analysed to achieve the desired operating band. The experimental results show that the impedance bandwidth is approximately 30 MHz (2.16 GHz to 2.19 GHz) for lower band and 40 MHz (3.29 GHz to 3.33 GHz) for higher band with an average peak gain of 6.59 dBiC and 5.52 dBiC, respectively. Several optimizations are performed to obtain the values of the antenna physical parameters. Moreover, the proposed antenna possesses compactness, light weight, simplicity, low cost, and circularly polarized. It is an attractive candidate for dual band satellite antennas where lower band can be used for uplink and upper band can be used for downlink. PMID:24982943

  3. Safety and Efficacy of Single Incision Laparoscopic Surgery for Total Extraperitoneal Inguinal Hernia Repair

    PubMed Central

    2011-01-01

    Almost 20 years after the first laparoscopic inguinal hernia repair was performed, single incision laparoscopic surgery (SILS™) is set to revolutionize minimally invasive surgery. However, the loss of triangulation must be overcome before the technique can be popularized. This study reports the first 100 laparoscopic total extraperitoneal hernia repairs using a single incision. The study cohort comprised 68 patients with a mean age of 44 (range, 18 to 83): 36 unilateral and 32 bilateral hernias. Twelve patients also underwent umbilical hernia repair with the Ventralex patch requiring no additional incisions. A 2.5-cm to 3-cm crescentic incision within the confines of the umbilicus was performed. Standard dissecting instruments and 52-cm/5.5-mm/300 laparoscope were used. Operation times were 50 minutes for unilateral and 80 minutes for bilateral. There was one conversion to conventional 3-port laparoscopic repair and none to open surgery. Outpatient surgery was achieved in all (except one). Analgesic requirements were minimal: 8 Dextropropoxyphene tablets (range, 0 to 20). There were no intraoperative or postoperative complications with a high patient satisfaction score. Single-incision laparoscopic hernia repair is safe and efficient simply by modifying dissection techniques (so-called “inline” and “vertical”). Comparable success can be obtained while negating the risks of bowel and vascular injuries from sharp trocars and achieving improved cosmetic results. PMID:21902942

  4. Adhesive bonded structural repair. I - Materials and processes, damage assessment and repair

    NASA Astrophysics Data System (ADS)

    Wegman, Raymond F.; Tullos, Thomas R.

    1993-08-01

    A standard method for the repair of adhesive bonded and composite laminate structures is introduced. Suitable materials and equipment for making satisfactory repairs are identified. Methods by which structures may be inspected, both before and after repair, are discussed. The objective in selecting the methods and materials is to restore the structure to its original integrity, i.e., to make a permanent repair. The use of these methods is recommended to promote standardized repair procedures.

  5. Modulation of Rhamm (CD168) for selective adipose tissue development

    DOEpatents

    Turley, Eva A; Bissell, Mina J

    2014-05-06

    Herein is described the methods and compositions for modulation of Rhamm, also known as CD 186, and its effects on wound repair, muscle differentiation, bone density and adipogeneisis through its ability to regulate mesenchymal stem cell differentiation. Compositions and methods are provided for blocking Rhamm function for selectively increasing subcutaneous, but not, visceral fat. Compositions and methods for modulating Rhamm in wound repair are also described.

  6. Point-of-care instrument for monitoring tissue health during skin graft repair

    NASA Astrophysics Data System (ADS)

    Gurjar, R. S.; Seetamraju, M.; Zhang, J.; Feinberg, S. E.; Wolf, D. E.

    2011-06-01

    We have developed the necessary theoretical framework and the basic instrumental design parameters to enable mapping of subsurface blood dynamics and tissue oxygenation for patients undergoing skin graft procedures. This analysis forms the basis for developing a simple patch geometry, which can be used to map by diffuse optical techniques blood flow velocity and tissue oxygenation as a function of depth in subsurface tissue.skin graft, diffuse correlation analysis, oxygen saturation.

  7. Pediatric ocular injury secondary to a Burmese python bite.

    PubMed

    Behrens, Alice W; Jones, Maria H; Lowery, R Scott

    2018-03-22

    We report the case of a 6-year-old girl with a penetrating ocular injury caused by a Burmese python. She received intravenous cefazolin before presenting and was treated thereafter with daily topical antibiotics and atropine. Six weeks after injury, she underwent cataract extraction and sulcus implantation of an intraocular lens and iris synechiolysis, with postoperative patching. Final visual outcome was excellent despite no globe repair was performed. Published by Elsevier Inc.

  8. Repair techniques for celion/LARC-160 graphite/polyimide composite structures

    NASA Technical Reports Server (NTRS)

    Jones, J. S.; Graves, S. R.

    1984-01-01

    The large stiffness-to-weight and strength-to-weight ratios of graphite composite in combination with the 600 F structural capability of the polyimide matrix can reduce the total structure/TPS weight of reusable space vehicles by 20-30 percent. It is inevitable that with planned usage of GR/PI structural components, damage will occur either in the form of intrinsic flaw growth or mechanical damage. Research and development programs were initiated to develop repair processes and techniques specific to Celion/LARC-160 GR/PI structure with emphasis on highly loaded and lightly loaded compression critical structures for factory type repair. Repair processes include cocure and secondary bonding techniques applied under vacuum plus positive autoclave pressure. Viable repair designs and processes are discussed for flat laminates, honeycomb sandwich panels, and hat-stiffened skin-stringer panels. The repair methodology was verified through structural element compression tests at room temperature and 315 C (600 F).

  9. Glenn Refractory Adhesive for Bonding and Exterior Repair (GRABER) Developed for Repairing Shuttle Damage

    NASA Technical Reports Server (NTRS)

    Singh, Mrityunjay; Shpargel, Tarah P.

    2005-01-01

    Advanced in-space repair technologies for reinforced carbon/carbon composite (RCC) thermal protection system (TPS) structures are critically needed for the space shuttle Return To Flight (RTF) efforts. These technologies are also critical for the repair and refurbishment of thermal protection system structures of future Crew Exploration Vehicles of space exploration programs. The Glenn Refractory Adhesive for Bonding and Exterior Repair (GRABER) material developed at the NASA Glenn Research Center has demonstrated capabilities for repair of small cracks and damage in RCC leading-edge material. The concept consists of preparing an adhesive paste of desired ceramic in a polymer/phenolic resin matrix with appropriate additives, such as surfactants, and then applying the paste into the damaged or cracked area of the RCC composite components with caulking guns. The adhesive paste cures at 100 to 120 C and transforms into a high-temperature ceramic during simulated vehicle reentry testing conditions.

  10. In utero repair of myelomeningocele: experimental pathophysiology, initial clinical experience, and outcomes.

    PubMed

    Farmer, Diana L; von Koch, Cornelia S; Peacock, Warwick J; Danielpour, Moise; Gupta, Nalin; Lee, Hanmin; Harrison, Michael R

    2003-08-01

    Experimental work raises the possibility that in utero repair of myelomeningocele (MMC) may improve lower extremity, bladder, and bowel function, ameliorate the Arnold-Chiari malformation, and decrease the need for postnatal shunting. We previously developed fetal lamb models to create and reverse lower extremity damage and the Arnold-Chiari malformation in utero. We then applied our extensive experience with fetal surgery, including fetal endoscopic (fetoscopic) surgical manipulation, to develop techniques for MMC repair. A tertiary referral center. All patients treated between 1998 and 2002 for a prenatally diagnosed MMC. Either fetoscopic MMC repair, fetoscopic patch repair, or limited maternal hysterotomy and microsurgical 3-layered fetal MMC repair was performed. Gestational age at delivery, survival, neurologic outcome, and need for ventricular shunting at 1 year. Complete fetoscopic repair was accomplished in 1 fetus. Two other fetuses underwent partial fetoscopic procedures. The remaining 10 patients underwent limited maternal hysterotomy and microsurgical 3-layered fetal MMC repair. Four of 13 patients died, and the mean gestational age at delivery of 11 fetuses born alive was 31 weeks. Five of 9 required ventricular shunting by age 1 year. In 2 patients, lower extremity function improved by more than 2 vertebral levels compared with prenatal ultrasonography. Five of 10 patients who lived longer than 3 weeks required postnatal wound revision within 7 days after birth. Fetoscopic repair, although feasible, does not yet yield optimal surgical results. Open surgical repair before 22 weeks' gestation is physiologically sound and technically feasible. One third of patients appear to be spared the need for a shunt at age 1 year, but improvement in distal neurologic function is less clear. Additionally, fetal mortality is associated with this procedure. Our results complement the data published by groups at Children's Hospital of Philadelphia, in Pennsylvania, and Vanderbilt University, Nashville, Tenn. A National Institutes of Health-sponsored prospective randomized trial is now underway at these 3 centers to compare fetal repair with postnatal repair.

  11. Macronutrient balancing affects patch departure by guerezas (Colobus guereza).

    PubMed

    Johnson, Caley A; Raubenheimer, David; Chapman, Colin A; Tombak, Kaia J; Reid, Andrea J; Rothman, Jessica M

    2017-04-01

    Foraging strategies are central in shaping social structure and grouping patterns in primates. We address Colobus guereza foraging strategies by investigating their patch departure decisions in relation to diet composition and nutrition. We examine whether guerezas are constrained in their intake of food in patches and thereby forage according to a fixed amount strategy that dictates patch departure. Additionally, we assess whether guereza employ a fixed time strategy or attempt to balance nutrients when foraging. We measured food patch occupancy time, intake rates, and analyzed foods for macronutrients, fiber, and condensed tannins. We determined that guerezas do not employ a fixed time foraging strategy; patch residence time varied widely between 1 and 290 min. They also did not depart patches or stop eating when they reached a specific intake of dry mass, macronutrients, or condensed tannins. However, guerezas maintained a macronutrient balance when feeding across patches, and the balance of protein to non-protein energy (fats and carbohydrates) in patches is the best indicator of time adult guerezas spent feeding in patches. Previous studies have shown that the protein-to-fiber ratio is important in predicting food selection for folivores and their biomass; however, we found that guerezas did not maximize protein and minimize fiber intake while foraging in patches, nor did they stay longer in patches with the highest ratio of protein to fiber concentrations. This study raises questions about the nutritional and social implications of patch depletion as a foraging strategy in folivorous monkeys where food limitation predicts competitive and social regimes. Am. J. Primatol. 79:e22495, 2017. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  12. Pretreatment of pericardial patches with antibiotics does not alter patch healing in vivo.

    PubMed

    Bai, Hualong; Kuwahara, Go; Wang, Mo; Brownson, Kirstyn E; Foster, Trenton R; Yamamoto, Kota; Xing, Ying; Dardik, Alan

    2016-04-01

    Pretreatment with antibiotics is commonly performed before surgical implantation of prosthetic materials. We previously showed that pericardial patches are infiltrated by macrophages and arterial stem cells after implantation into an artery. We hypothesized that antibiotic pretreatment would diminish the number of cells infiltrating into the patch, potentially affecting early neointimal formation. Bovine pericardial patches were pretreated with saline, bacitracin (500 U/mL), or cephalexin (10 mg/mL) for 30 minutes before implantation into the Wistar rat infrarenal aorta. Patches were retrieved on day 7 or day 30 and analyzed for histology and cell infiltration. Markers of proliferation, apoptosis, vascular cell identity, and M1 and M2 macrophage subtypes were examined using immunofluorescence and immunohistochemistry. Extracted proteins were analyzed by Western blot. At day 7, pericardial patches pretreated with bacitracin or cephalexin showed similar amounts of neointimal thickening (P = .55) and cellular infiltration (P = .42) compared with control patches. Patches pretreated with antibiotics showed similar proliferation (P = .09) and apoptosis (P = .84) as control patches. The cell composition of the neointima in pretreated patches was similar to control patches, with a thin endothelial layer overlying a thin layer of smooth muscle cells (P = .45), and containing similar numbers of CD34-positive (P = .26) and vascular endothelial growth factor receptor 2-positive (P = .31) cells. Interestingly, within the body of the patch, there were fewer macrophages (P = .0003) and a trend towards fewer endothelial progenitor cells (P = .051). No M1 macrophages were found in or around any of the patches. M2 macrophages were present around the patches, and there was no difference in numbers of M2 macrophages surrounding control patches and patches pretreated with antibiotics (P = .24). There was no difference in neointimal thickness at day 30 between control patches and patches pretreated with antibiotics (P = .52). Pretreatment of bovine pericardial patches with the antibiotics bacitracin or cephalexin has no detrimental effect on early patch healing, with similar neointimal thickness, cellular infiltration, and numbers of M2 macrophages compared with control patches. These results suggest that the host vessel response to patch angioplasty using pericardial patches is adaptive remodeling (eg, arterial healing). Published by Elsevier Inc.

  13. Bond strength of repaired amalgam restorations.

    PubMed

    Rey, Rosalia; Mondragon, Eduardo; Shen, Chiayi

    2015-01-01

    This in vitro study investigated the interfacial flexural strength (FS) of amalgam repairs and the optimal combination of repair materials and mechanical retention required for a consistent and durable repair bond. Amalgam bricks were created, each with 1 end roughened to expose a fresh surface before repair. Four groups followed separate repair protocols: group 1, bonding agent with amalgam; group 2, bonding agent with composite resin; group 3, mechanical retention (slot) with amalgam; and group 4, slot with bonding agent and amalgam. Repaired specimens were stored in artificial saliva for 1, 10, 30, 120, or 360 days before being loaded to failure in a 3-point bending test. Statistical analysis showed significant changes in median FS over time in groups 2 and 4. The effect of the repair method on the FS values after each storage period was significant for most groups except the 30-day storage groups. Amalgam-amalgam repair with adequate condensation yielded the most consistent and durable bond. An amalgam bonding agent could be beneficial when firm condensation on the repair surface cannot be achieved or when tooth structure is involved. Composite resin can be a viable option for amalgam repair in an esthetically demanding region, but proper mechanical modification of the amalgam surface and selection of the proper bonding system are essential.

  14. Resin composite repair: Quantitative microleakage evaluation of resin-resin and resin-tooth interfaces with different surface treatments

    PubMed Central

    Celik, Cigdem; Cehreli, Sevi Burcak; Arhun, Neslihan

    2015-01-01

    Objective: The aim was to evaluate the effect of different adhesive systems and surface treatments on the integrity of resin-resin and resin-tooth interfaces after partial removal of preexisting resin composites using quantitative image analysis for microleakage testing protocol. Materials and Methods: A total of 80 human molar teeth were restored with either of the resin composites (Filtek Z250/GrandioSO) occlusally. The teeth were thermocycled (1000×). Mesial and distal 1/3 parts of the restorations were removed out leaving only middle part. One side of the cavity was finished with course diamond bur and the other was air-abraded with 50 μm Al2O3. They were randomly divided into four groups (n = 10) to receive: Group 1: Adper Single Bond 2; Group 2: All Bond 3; Group 3: ClearfilSE; Group 4: BeautiBond, before being repaired with the same resin composite (Filtek Z250). The specimens were re-thermocycled (1000×), sealed with nail varnish, stained with 0.5% basic fuchsin, sectioned mesiodistally and photographed digitally. The extent of dye penetration was measured by image analysis software (ImageJ) for both bur-finished and air-abraded surfaces at resin-tooth and resin-resin interfaces. The data were analyzed statistically. Results: BeautiBond exhibited the most microleakage at every site. Irrespective of adhesive and initial composite type, air-abrasion showed less microleakage except for BeautiBond. The type of initial repaired restorative material did not affect the microleakage. BeautiBond adhesive may not be preferred in resin composite repair in terms of microleakage prevention. Conclusions: Surface treatment with air-abrasion produced the lowest microleakage scores, independent of the adhesive systems and the pre-existing resin composite type. Pre-existing composite type does not affect the microleakage issue. All-in-one adhesive resin (BeautiBond) may not be preferred in resin composite repair in terms of microleakage prevention. PMID:25713491

  15. Self-Repairing Fatigue Damage in Metallic Structures for Aerospace Vehicles Using Shape Memory Alloy Self-healing (SMASH) Technology

    NASA Technical Reports Server (NTRS)

    Wright, M. Clara; Manuel, Michele; Wallace, Terryl; Newman, Andy; Brinson, Kate

    2015-01-01

    This DAA is for the Phase II webinar presentation of the ARMD-funded SMASH technology. A self-repairing aluminum-based composite system has been developed using liquid-assisted healing theory in conjunction with the shape memory effect of wire reinforcements. The metal matrix composite was thermodynamically designed to have a matrix with a relatively even dispersion of low-melting phase, allowing for repair of cracks at a pre-determined temperature. Shape memory alloy wire reinforcements were used within the composite to provide crack closure. Investigators focused the research on fatigue cracks propagating through the matrix in order to optimize and computer model the SMASH technology for aeronautical applications.

  16. Analysis and Testing of a Metallic Repair Applicable to Pressurized Composite Aircraft Structure

    NASA Technical Reports Server (NTRS)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.

    2014-01-01

    Development of repair technology is vital to the long-term application of new structural concepts on aircraft structure. The design, analysis, and testing of a repair concept applicable to a stiffened composite panel based on the Pultruded Rod Stitched Efficient Unitized Structure was recently completed. The damage scenario considered was a mid-bay to mid-bay saw-cut with a severed stiffener, flange, and skin. A bolted metallic repair was selected so that it could be easily applied in the operational environment. The present work describes results obtained from tension and pressure panel tests conducted to validate both the repair concept and finite element analysis techniques used in the design effort. Simulation and experimental strain and displacement results show good correlation, indicating that the finite element modeling techniques applied in the effort are an appropriate compromise between required fidelity and computational effort. Static tests under tension and pressure loadings proved that the proposed repair concept is capable of sustaining load levels that are higher than those resulting from the current working stress allowables. Furthermore, the pressure repair panel was subjected to 55,000 pressure load cycles to verify that the design can withstand a life cycle representative for a transport category aircraft. These findings enable upward revision of the stress allowables that had been kept at an overly-conservative level due to concerns associated with repairability of the panels. This conclusion enables more weight efficient structural designs utilizing the composite concept under investigation.

  17. Phase diagrams of Janus fluids with up-down constrained orientations

    NASA Astrophysics Data System (ADS)

    Fantoni, Riccardo; Giacometti, Achille; Maestre, Miguel Ángel G.; Santos, Andrés

    2013-11-01

    A class of binary mixtures of Janus fluids formed by colloidal spheres with the hydrophobic hemispheres constrained to point either up or down are studied by means of Gibbs ensemble Monte Carlo simulations and simple analytical approximations. These fluids can be experimentally realized by the application of an external static electrical field. The gas-liquid and demixing phase transitions in five specific models with different patch-patch affinities are analyzed. It is found that a gas-liquid transition is present in all the models, even if only one of the four possible patch-patch interactions is attractive. Moreover, provided the attraction between like particles is stronger than between unlike particles, the system demixes into two subsystems with different composition at sufficiently low temperatures and high densities.

  18. Assessment of patches attributes along the Urban Development Gradient

    NASA Astrophysics Data System (ADS)

    Kopel, Daniella; Wittenberg, lea; Malkinson, Dan

    2014-05-01

    The world is increasingly urban. If current trends maintain, by 2050 the global urban population is estimated to be 6.3 billion, nearly doubling the world population in 2010. Consequently, more than 60% of the area projected to be urban in 2030 has yet to be built, replacing the open and agriculture lands with construction and infrastructure. The open green patches (OGP), within the urban matrix, are essential for healthy and wellness of cities by supplying the city's ecological services (Mausback and Seybold, 1998). Regarding future trends, there is a need and obligation to insure the functional and sustainability of the city's OPG. Urban vegetation composition and diversity in the OGP had long been considered as an indication for ecologically functioning systems. Furthermore, urban soil is also essential for the sustainability and function of the urban habitat and ecological services, such as maintaining groundwater restraining urban floods etc. (Lehmann and Stahr 2007). There is no single set of rules to classify a functional urban green patch worth preserving. The aim of this study is to examine the effects of patch properties (including geometry, age, type and location along the urban gradient, connectivity, and urban matrix density) on the presence, abundance and characteristics of vegetation and soil conditions of remnant patches The inspired purpose is to eventually find an assessment for urban open green patches OGP quality by linking, patches attributes, plants indexes and soil quality indexes The research is conducted in the city of Haifa, which is located on the northern part of Mount Carmel in the north-western part of Israel . Mean annual rainfall, 550-800 mm, varies with latitude and the mean temperature is 18.80c. Modern Haifa is a relatively young city which maintains remnant vegetation patches within its municipal boundary. 32 OGP were selected in nine categories (size: small, medium and large, distance from city edge: far, average, near), in which vegetation was surveyed. . All vascular plant species were recorded and identified. The mineral soils (A horizon, depth 10-15 cm) were collected to obtain a constant sample size after removing surface litter and organic matter. The samples were analyzed for mineral and structure properties. Preliminary results of the plant survey and analysis indicated that the patches' vegetation is highly diverse. Within the large patches, regardless of their location along the urban development gradient, higher sub-habitat diversity and plants diversity were observed. The diversity is high for local and exotic species alike. In the medium and small size patches, also regardless of their location, there is a diversity of plant composition that may be connected to different disturbances or matrix related effect not yet considered in the study. Preliminary results of the soil survey and analysis indicated that more than 75% of the soil samples taken from the OGP, regardless of their location in the urban development gradient, exhibited a considerable changes in soil profile, compared to "natural" soils and significant alternations in the physical properties were also observed. The substance that was found in the remnant OGP in Haifa is different from soil, however, links between the urban-soils altered properties and the vegetation composition in those patches, and there relationships are not fully understood.

  19. Can repair increase the longevity of composite resins? Results of a 10-year clinical trial.

    PubMed

    Fernández, E; Martín, J; Vildósola, P; Oliveira Junior, O B; Gordan, V; Mjor, I; Bersezio, C; Estay, J; de Andrade, M F; Moncada, G

    2015-02-01

    The aim of this double-blind clinical trial was to assess the longevity of repairs to localized clinical defects in composite resin restorations that were initially planned to be treated with a restoration replacement. Twenty-eight patients aged 18-80 years old with 50 composite resin restorations (CR) were recruited. The restorations with localized, marginal, anatomical deficiencies and/or secondary caries adjacent to CR that were "clinically judged" to be suitable for repair or replacement according to the USPHS criteria were randomly assigned to Repair (n=25) or Replacement (n=25) groups, and the quality of the restorations was scored according to the modified USPHS criteria. The restorations were blind and two examiners scored them at baseline (Cohen Kappa agreement score 0.74) and at ten years (Cohen Kappa agreement score 0.87) restorations. Wilcoxon tests were performed for comparisons within the same group (95% CI), and Friedman tests were utilized for multiple comparisons between the different years within each group. Over the decade, the two groups behaved similarly on the parameters of marginal adaptation (MA) (p>0.05), secondary caries (SC) (p>0.05), anatomy (A) (p<0.05), and colour (C) (p>0.05). Given that the MA, SC, A and C parameters behaved similarly in both groups, the repair of composite resins should be elected when clinically indicated, because it is a minimally invasive treatment that can consistently increase the longevity of restorations. The repair of defective composite resins as an alternative treatment to increase their longevity proved to be a safe and effective treatment in the long term. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. In vivo laser assisted end-to-end anastomosis with ICG-infused chitosan patches

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Matteini, Paolo; Esposito, Giuseppe; Scerrati, Alba; Albanese, Alessio; Puca, Alfredo; Maira, Giulio; Rossi, Giacomo; Pini, Roberto

    2011-07-01

    Laser assisted vascular repair is a new optimized technique based on the use of ICG-infused chitosan patch to close a vessel wound, with or even without few supporting single stitches. We present an in vivo experimental study on an innovative end-to-end laser assisted vascular anastomotic (LAVA) technique, performed with the application of ICGinfused chitosan patches. The photostability and the mechanical properties of ICG-infused chitosan films were preliminary measured. The in vivo study was performed in 10 New Zealand rabbits. After anesthesia, a 3-cm segment of the right common carotid artery was exposed, thus clamped proximally and distally. The artery was then interrupted by means of a full thickness cut. Three single microsutures were used to approximate the two vessel edges. The ICG-infused chitosan patch was rolled all over the anastomotic site and welded by the use of a diode laser emitting at 810 nm and equipped with a 300 μm diameter optical fiber. Welding was obtained by delivering single laser spots to induce local patch/tissue adhesion. The result was an immediate closure of the anastomosis, with no bleeding at clamps release. Thus animals underwent different follow-up periods, in order to evaluate the welded vessels over time. At follow-up examinations, all the anastomoses were patent and no bleeding signs were documented. Samples of welded vessels underwent histological examinations. Results showed that this technique offer several advantages over conventional suturing methods: simplification of the surgical procedure, shortening of the operative time, better re-endothelization and optimal vascular healing process.

  1. Carboxylated Agarose (CA)-Silk Fibroin (SF) Dual Confluent Matrices Containing Oriented Hydroxyapatite (HA) Crystals: Biomimetic Organic/Inorganic Composites for Tibia Repair.

    PubMed

    Hu, Jing-Xiao; Ran, Jia-Bing; Chen, Si; Jiang, Pei; Shen, Xin-Yu; Tong, Hua

    2016-07-11

    By in situ combining the dual cross-linking matrices of the carboxylated agarose (CA) and the silk fibroin (SF) with the hydroxyapatite (HA) crystals, the CA-SF/HA composites with optimal physicochemical and biological properties were obtained, which were designed to meet the clinical needs of load-bearing bone repair. With the synergistic modulation of the dual organic matrices, the HA nanoparticles presented sheet and rod morphologies due to the preferred orientation, which successfully simulated the biomineralization in nature. The chemical reactivity of the native agarose (NA) was significantly enhanced via carboxylation, and the CA exhibited higher thermal stability than the NA. In the presence of SF, the composites showed optimal mechanical properties that could meet the standard of bone repair. The degradation of the composites in the presence of CA and SF was significantly delayed such that the degradation rate of the implant could satisfy the growth rate of the newly formed bone tissue. The in vitro tests confirmed that the CA-SF/HA composite scaffolds enabled the MG63 cells to proliferate and differentiate well, and the CA/HA composite presented greater capability of promoting the cell behaviors than the NA/HA composite. After 24 days of implantation, newly formed bone was observed at the tibia defect site and around the implant. Extensive osteogenesis was presented in the rats treated with the CA-SF/HA composites. In general, the CA-SF/HA composites prepared in this work had the great potential to be applied for repairing large bone defects.

  2. Emerging Composite Technologies

    NASA Technical Reports Server (NTRS)

    Wright, R.; Austin, R. (Technical Monitor)

    2000-01-01

    The purpose of this presentation is to discuss the external tank composite applications, and composite development as it relates to the the cryogenic tankage, composite repair, cryogenic feedlines, and LO2 compatible composites.

  3. NEIL3 Repairs Telomere Damage during S Phase to Secure Chromosome Segregation at Mitosis.

    PubMed

    Zhou, Jia; Chan, Jany; Lambelé, Marie; Yusufzai, Timur; Stumpff, Jason; Opresko, Patricia L; Thali, Markus; Wallace, Susan S

    2017-08-29

    Oxidative damage to telomere DNA compromises telomere integrity. We recently reported that the DNA glycosylase NEIL3 preferentially repairs oxidative lesions in telomere sequences in vitro. Here, we show that loss of NEIL3 causes anaphase DNA bridging because of telomere dysfunction. NEIL3 expression increases during S phase and reaches maximal levels in late S/G2. NEIL3 co-localizes with TRF2 and associates with telomeres during S phase, and this association increases upon oxidative stress. Mechanistic studies reveal that NEIL3 binds to single-stranded DNA via its intrinsically disordered C terminus in a telomere-sequence-independent manner. Moreover, NEIL3 is recruited to telomeres through its interaction with TRF1, and this interaction enhances the enzymatic activity of purified NEIL3. Finally, we show that NEIL3 interacts with AP Endonuclease 1 (APE1) and the long-patch base excision repair proteins PCNA and FEN1. Taken together, we propose that NEIL3 protects genome stability through targeted repair of oxidative damage in telomeres during S/G2 phase. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  4. Long-term monitoring of mechanical properties of FRP repair materials.

    DOT National Transportation Integrated Search

    2013-07-01

    Fiber- reinforced polymer composites (FRP) are an attractive repair option for existing concrete structures. : CDOT has used this material on some projects, in particular the repair of the Castlewood Canyon Bridge in : 2003. Further use of the materi...

  5. Integrating landscape ecology and geoinformatics to decipher landscape dynamics for regional planning.

    PubMed

    Dikou, Angela; Papapanagiotou, Evangelos; Troumbis, Andreas

    2011-09-01

    We used remote sensing and GIS in conjunction with multivariate statistical methods to: (i) quantify landscape composition (land cover types) and configuration (patch density, diversity, fractal dimension, contagion) for five coastal watersheds of Kalloni gulf, Lesvos Island, Greece, in 1945, 1960, 1971, 1990 and 2002/2003, (ii) evaluate the relative importance of physical (slope, geologic substrate, stream order) and human (road network, population density) variables on landscape composition and configuration, and (iii) characterize processes that led to land cover changes through land cover transitions between these five successive periods in time. Distributions of land cover types did not differ among the five time periods at the five watersheds studied because the largest cumulative changes between 1945 and 2002/2003 did not take place at dominant land cover types. Landscape composition related primarily to the physical attributes of the landscape. Nevertheless, increase in population density and the road network were found to increase heterogeneity of the landscape mosaic (patchiness), complexity of patch shape (fractal dimension), and patch disaggregation (contagion). Increase in road network was also found to increase landscape diversity due to the creation of new patches. The main processes involved in land cover changes were plough-land abandonment and ecological succession. Landscape dynamics during the last 50 years corroborate the ecotouristic-agrotouristic model for regional development to reverse trends in agricultural land abandonment and human population decline and when combined with hypothetical regulatory approaches could predict how this landscape could develop in the future, thus, providing a valuable tool to regional planning.

  6. Damage Tolerant Repair Techniques for Pressurized Aircraft Fuselages

    DTIC Science & Technology

    1994-06-06

    crack patching effectiveness, long cracks ( Erdogan ) 186 Vii Acknowledgments My three years of Ph.D. work would have been impossible without the...fatigue GST, GLARE 2 " " 20 20 static, no fatigue *Unidirectional SP500 carbon/epoxy tape . *Fatigue load did not initiate a crack. The saw cut was...assurnption It further implies zero crack opening under the pat(:r The Erdogan solutior (51 for two Coiinear Ctacks can be expressed as: %A F -. " (621 F

  7. Peripheral Nerve Repair and Prevention of Neuroma Formation

    DTIC Science & Technology

    2014-09-01

    Magee1), ADRB3, β arrestin, Patched 1 (Ptch1) and 2, desert hedgehog (Dhh), smoothen (Smo), Src kinase, and UCP1. (Months 6-36) c. We will also use the...antibody. Figure 9. Representative photomicrographs of desert hedgehog staining in perineurial fibroblasts. A.) C57/BL6 mouse nerve was isolated 3...days after BMP2 induction stained with desert hedgehog (red) and NF (green). P. perineurium; E. endoneurium. Note that the mouse nerve, unlike the

  8. Surgical management of anomalous pulmonary venous connection to the superior vena cava - early results

    PubMed Central

    Chandra, Dinesh; Gupta, Anubhav; Nath, Ranjit K.; kazmi, Aamir; Grover, Vijay; Gupta, Vijay K.

    2013-01-01

    Background The anatomical variability in patients with anomalous pulmonary venous connection to superior vena cava presents a surgical challenge. The problem is further compounded by the common occurrence of postoperative complications like arrhythmias and obstruction of the superior vena cava or pulmonary veins. We present our experience of managing this subset using the two patch and Warden's techniques. Patients and methods Between June 2011 and September 2012, 7 patients with APVC to the SVC were operated in our institute. After delineating the anatomy, five of them had a two patch repair and two were managed with Warden's technique. Results There was no in-hospital mortality or early mortality over a mean follow-up of 9.66 ± 3.88 months (range 6–15 months). All the patients on follow-up had unobstructed pulmonary venous and SVC drainage on echocardiography and all of them were in normal sinus rhythm. Conclusions Anomalous pulmonary venous connection to superior vena cava is a challenging subset of patients in whom the surgical management needs to be individualized. The detailed anatomy must be delineated using echocardiography with or without CT angiography before deciding the surgical plan. This entity can be repaired with excellent immediate and early results. However, these patients must be closely followed up for complications like systemic and pulmonary venous obstruction and sinus node dysfunction. PMID:24206880

  9. A Comparison of Electrospun Polymers Reveals Poly(3-Hydroxybutyrate) Fiber as a Superior Scaffold for Cardiac Repair

    PubMed Central

    Castellano, Delia; Blanes, María; Marco, Bruno; Cerrada, Inmaculada; Ruiz-Saurí, Amparo; Pelacho, Beatriz; Araña, Miriam; Montero, Jose A.; Cambra, Vicente; Prosper, Felipe

    2014-01-01

    The development of biomaterials for myocardial tissue engineering requires a careful assessment of their performance with regards to functionality and biocompatibility, including the immune response. Poly(3-hydroxybutyrate) (PHB), poly(e-caprolactone) (PCL), silk, poly-lactic acid (PLA), and polyamide (PA) scaffolds were generated by electrospinning, and cell compatibility in vitro, and immune response and cardiac function in vitro and in vivo were compared with a noncrosslinked collagen membrane (Col) control material. Results showed that cell adhesion and growth of mesenchymal stem cells, cardiomyocytes, and cardiac fibroblasts in vitro was dependent on the polymer substrate, with PHB and PCL polymers permitting the greatest adhesion/growth of cells. Additionally, polymer substrates triggered unique expression profiles of anti- and pro-inflammatory cytokines in human peripheral blood mononuclear cells. Implantation of PCL, silk, PLA, and PA patches on the epicardial surface of healthy rats induced a classical foreign body reaction pattern, with encapsulation of polymer fibers and induction of the nonspecific immune response, whereas Col and PHB patches were progressively degraded. When implanted on infarcted rat heart, Col, PCL, and PHB reduced negative remodeling, but only PHB induced significant angiogenesis. Importantly, Col and PHB modified the inflammatory response to an M2 macrophage phenotype in cardiac tissue, indicating a more beneficial reparative process and remodeling. Collectively, these results identify PHB as a superior substrate for cardiac repair. PMID:24564648

  10. STS-121 Mission Patch

    NASA Image and Video Library

    2005-06-01

    STS121-S-001 (June 2005) --- The STS-121 patch depicts the space shuttle docked with the International Space Station (ISS) in the foreground, overlaying the astronaut symbol with three gold columns and a gold star. The ISS is shown in the configuration that it will be in during the STS-121 mission. The background shows the nighttime Earth with a dawn breaking over the horizon. STS-121, ISS mission ULF1.1, is the final Shuttle Return to Flight test mission. This utilization and logistics flight will bring a multipurpose logistics module (MPLM) to the ISS with several thousand pounds of new supplies and experiments. In addition, some new orbital replacement units (ORUs) will be delivered and stowed externally on ISS on a special pallet. These ORUs are spares for critical machinery located on the outside of the ISS. During this mission the crew will also carry out testing of shuttle inspection and repair hardware, as well as evaluate operational techniques and concepts for conducting on-orbit inspection and repair. The NASA insignia design for space shuttle flights is reserved for use by the astronauts and for other official use as the NASA Administrator may authorize. Public availability has been approved only in the forms of illustrations by the various news media. When and if there is any change in this policy, which is not anticipated, the change will be publicly announced. Photo credit: NASA

  11. Repair of impact damaged utility poles with fiber reinforced polymers (FRP), phase II.

    DOT National Transportation Integrated Search

    2015-06-01

    Vehicle collisions with steel or aluminum utility poles are common occurrences that yield substantial but often repairable : damage. This project investigates the use of a fiber-reinforced polymer (FRP) composite system for in situ repair that : mini...

  12. Combined open and laparoscopic approach to chronic pain following open inguinal hernia repair.

    PubMed

    Rosen, M J; Novitsky, Y W; Cobb, W S; Kercher, K W; Heniford, B Todd

    2006-03-01

    Chronic groin pain is the most common long-term complication after open inguinal hernia repair. Traditional surgical management of the associated neuralgia consists of injection therapy followed by groin exploration, mesh removal, and nerve transection. The resultant hernia defect may be difficult to repair from an anterior approach. We evaluate the outcomes of a combined laparoscopic and open approach for the treatment of chronic groin pain following open inguinal herniorrhaphy. All patients who underwent groin exploration for chronic neuralgia after a prior open inguinal hernia repair were prospectively analyzed. Patient demographics, type of prior hernia repair, and prior nonoperative therapies were recorded. The operation consisted of a standard three trocar laparoscopic transabdominal preperitoneal hernia repair, followed by groin exploration, mesh removal, and nerve transection. Outcome measures included recurrent groin pain, numbness, hernia recurrence, and complications. Twelve patients (11 male and 1 female) with a mean age of 41 years (range 29-51) underwent combined laparoscopic and open treatment for chronic groin pain. Ten patients complained of unilateral neuralgia, one patient had bilateral complaints, and one patient complained of orchalgia. All patients failed at least two attempted percutaneous nerve blocks. Prior repairs included Lichtenstein (n=9), McVay (n=1), plug and patch (n=1), and Shouldice (n=1). There were no intraoperative complications or wound infections. With a minimum of 6 weeks follow up, all patients were significantly improved. One patient complained of intermittent minor discomfort that required no further therapy. Two patients had persistent numbness in the ilioinguinal nerve distribution but remained satisfied with the procedure. A combined laparoscopic and open approach for postherniorrhaphy groin pain results in good to excellent patient satisfaction with no perioperative morbidity. It may be the preferred technique for the definitive management of chronic neuralgia after prior open hernia repair.

  13. Surface water connectivity drives richness and composition of Arctic lake fish assemblages

    USGS Publications Warehouse

    Laske, Sarah M.; Haynes, Trevor B.; Rosenberger, Amanda E.; Koch, Joshua C.; Wipfli, Mark S.; Whitman, Matthew; Zimmerman, Christian E.

    2016-01-01

    This work provides useful baseline information on the processes that drive the relations between patch connectivity and fish species richness and assemblage composition. The environmental processes that organise fish assemblages in Arctic lakes are likely to change in a warming climate.

  14. [Where does laparoscopy fit in the treatment of inguinal hernia in 2003?].

    PubMed

    Gainant, A

    2003-06-01

    Meta-analysis of randomized studies has clearly shown that prosthetic repair of inguinal hernias decreases the risk of hernia recurrence when compared with herniorraphy without prosthesis; but the optimal route for insertion of the prosthetic patch (laparoscopic versus open inguinal approach) remains in dispute. Meta-analysis of randomized studies comparing laparoscopic with open prosthetic hernia repair suggest that laparoscopy is associated with less post-operative pain (both early and late), a quicker recovery, and earlier return to work. Yet this is at the price of longer operative time and an incidence of rare but potentially severe complications. On the basis of these randomized studies, the ANAES in France and the NICE in England have put forth recommendations which accept the indication for laparoscopic repair in recurrent and bilateral hernias, if done by surgeons experienced in laparoscopic technique. For unilateral hernia in adults, laparoscopic repair has shown no proof of superiority over open prosthetic repair in terms of mortality, morbidity, or recurrence rate. The principal advantage of the laparoscopic approach seems to be improved patient comfort; its disadvantage is higher cost and technical difficulty with a prolonged learning curve. The excess costs of the laparoscopic approach may be compensated by an earlier return to work. At present, the laparoscopic repair of hernias finds its clinical niche in patients with bilateral or recurrent hernias or in patients with unilateral hernia who desire a minimal period of postoperative disability.

  15. Defence Capability Plan 2009 (Australian Department of Defence). Public Version

    DTIC Science & Technology

    2009-01-24

    workings or Intellectual Property . > Armoured vehicles. This capability relates to the repair, maintenance and some upgrades of specialist military...cryptographic equipment. > Composite and exotic materials. This is the ability to repair specialist alloys and composite materials, to develop new...manufacture of some high usage munitions, ammunition components, propellants and explosives. > Signature management. Includes the capabilities and coatings

  16. Characterization of a carbon fiber reinforced polymer repair system for structurally deficient steel piping

    NASA Astrophysics Data System (ADS)

    Wilson, Jeffrey M.

    This Dissertation investigates a carbon fiber reinforced polymer repair system for structurally deficient steel piping. Numerous techniques exist for the repair of high-pressure steel piping. One repair technology that is widely gaining acceptance is composite over-wraps. Thermal analytical evaluations of the epoxy matrix material produced glass transition temperature results, a cure kinetic model, and a workability chart. These results indicate a maximum glass transition temperature of 80°C (176°F) when cured in ambient conditions. Post-curing the epoxy, however, resulted in higher glass-transition temperatures. The accuracy of cure kinetic model presented is temperature dependent; its accuracy improves with increased cure temperatures. Cathodic disbondment evaluations of the composite over-wrap show the epoxy does not breakdown when subjected to a constant voltage of -1.5V and the epoxy does not allow corrosion to form under the wrap from permeation. Combustion analysis of the composite over-wrap system revealed the epoxy is flammable when in direct contact with fire. To prevent combustion, an intumescent coating was developed to be applied on the composite over-wrap. Results indicate that damaged pipes repaired with the carbon fiber composite over-wrap withstand substantially higher static pressures and exhibit better fatigue characteristics than pipes lacking repair. For loss up to 80 percent of the original pipe wall thickness, the composite over-wrap achieved failure pressures above the pipe's specified minimum yield stress during monotonic evaluations and reached the pipe's practical fatigue limit during cyclical pressure testing. Numerous repairs were made to circular, thru-wall defects and monotonic pressure tests revealed containment up to the pipe's specified minimum yield strength for small diameter defects. The energy release rate of the composite over-wrap/steel interface was obtained from these full-scale, leaking pipe evaluations and results indicate a large amount of scatter is associated with this test method. Due to the large amount of scatter present in the leaking pipe evaluations (energy release rate tests), a new laboratory specimen was created to evaluate mixed mode debonding of composite over-wrapped piping. The laboratory specimen results are much more conservative than the leaking pipe evaluations. The laboratory specimen results, however, agree quite favorably to a closed form solution developed in this Dissertation, as well as to energy release rate calculations performed by two different finite element analysis methods, the Modified Crack Closure Integral and the change in compliance method.

  17. Repair of through thickness corrosion/leaking defects in corroded pipelines using Fiber Reinforced Polymer overwrap

    NASA Astrophysics Data System (ADS)

    Nitheesh Kumar, P.; Khan, Vishwas Chandra; Balaganesan, G.; Pradhan, A. K.; Sivakumar, M. S.

    2018-04-01

    The present study is concerned with the repair of through thickness corrosion or leaking defects in metallic pipelines using a commercially available metallic seal and glass/epoxy composite. Pipe specimens are made with three different types of most commonly occurring through thickness corrosion/leaking defects. The metallic seal is applied over the through thickness corrosion/leaking defect and it is reinforced with glass/epoxy composite overwrap. The main objective of the metallic seal is to arrest the leak at live pressure. After reinforcing the metallic seal with glass/epoxy composite overwrap, the repaired composite wrap is able to sustain high pressures. Burst test is performed for different configurations of metallic seal and optimum configuration of metallic seal is determined. The optimum configurations of metallic seal for three different types of through thickness corrosion/leaking defects are further reinforced with glass/epoxy composite wrap and experimental failure pressure is determined by performing the burst test. An analytical model as per ISO 24817 has been developed to validate experimental results.

  18. Analysis and Test of Repair Concepts for a Carbon-Rod Reinforced Laminate

    NASA Technical Reports Server (NTRS)

    Baker, Donald J.; Rousseau, Carl Q.

    2000-01-01

    The use of pultruded carbon-epoxy rods for the reinforcement of composite laminates in some structures results in an efficient structural concept. The results of an analytical and experimental investigation of repair concepts of completely severed carbon-epoxy rods is presented. Three repair concepts are considered: (a) bonded repair with outside moldline and inside moldline doublers; (b) bonded repair with fasteners, and (c) bonded repair with outside moldline doubler only. The stiffness of the repairs was matched with the stiffness of the baseline specimen. The failure strains for the bonded repair with fasteners and the bonded repair with an outside moldline doubler exceeded a target design strain set for the repair concepts.

  19. Self Healing Composite for Aircraft's Structural Application

    NASA Astrophysics Data System (ADS)

    Teoh, S. H.; Chia, H. Y.; Lee, M. S.; Nasyitah, A. J. N.; Luqman, H. B. S. M.; Nurhidayah, S.; Tan, Willy. C. K.

    When one cuts himself, it is amazing to watch how quickly the body acts to mend the wound. Immediately, the body works to pull the skin around the cut back together. The concept of repair by bleeding of enclosed functional agents serves as the biomimetic inspiration of synthetic self repair systems. Such synthetic self repair systems are based on advancement in polymeric materials; the process of human thrombosis is the inspiration for the application of self healing fibres within the composite materials. Results based on flexural 3 point bend test on the prepared samples have shown that the doubled layer healed hollow fibre laminate subjected to a healing regime of 3 weeks has a healed strength increase of 27% compared to the damaged baseline laminate. These results gave us confidence that there is a great potential to adopt such self healing mechanism on actual composite parts like in aircraft's composite structures.

  20. Predation and landscape characteristics independently affect reef fish community organization.

    PubMed

    Stier, Adrian C; Hanson, Katharine M; Holbrook, Sally J; Schmitt, Russell J; Brooks, Andrew J

    2014-05-01

    Trophic island biogeography theory predicts that the effects of predators on prey diversity are context dependent in heterogeneous landscapes. Specifically, models predict that the positive effect of habitat area on prey diversity should decline in the presence of predators, and that predators should modify the partitioning of alpha and beta diversity across patchy landscapes. However, experimental tests of the predicted context dependency in top-down control remain limited. Using a factorial field experiment we quantify the effects of a focal predatory fish species (grouper) and habitat characteristics (patch size, fragmentation) on the partitioning of diversity and assembly of coral reef fish communities. We found independent effects of groupers and patch characteristics on prey communities. Groupers reduced prey abundance by 50% and gamma diversity by 45%, with a disproportionate removal of rare species relative to common species (64% and 36% reduction, respectively; an oddity effect). Further, there was a 77% reduction in beta diversity. Null model analysis demonstrated that groupers increased the importance of stochastic community assembly relative to patches without groupers. With regard to patch size, larger patches contained more fishes, but a doubling of patch size led to a modest (36%) increase in prey abundance. Patch size had no effect on prey diversity; however, fragmented patches had 50% higher species richness and modified species composition relative to unfragmented patches. Our findings suggest two different pathways (i.e., habitat or predator shifts) by which natural and/or anthropogenic processes can drive variation in fish biodiversity and community assembly.

  1. Recent progress in injectable bone repair materials research

    NASA Astrophysics Data System (ADS)

    Chen, Zonggang; Zhang, Xiuli; Kang, Lingzhi; Xu, Fei; Wang, Zhaoling; Cui, Fu-Zhai; Guo, Zhongwu

    2015-12-01

    Minimally invasive injectable self-setting materials are useful for bone repairs and for bone tissue regeneration in situ. Due to the potential advantages of these materials, such as causing minimal tissue injury, nearly no influence on blood supply, easy operation and negligible postoperative pain, they have shown great promises and successes in clinical applications. It has been proposed that an ideal injectable bone repair material should have features similar to that of natural bones, in terms of both the microstructure and the composition, so that it not only provides adequate stimulus to facilitate cell adhesion, proliferation and differentiation but also offers a satisfactory biological environment for new bone to grow at the implantation site. This article reviews the properties and applications of injectable bone repair materials, including those that are based on natural and synthetic polymers, calcium phosphate, calcium phosphate/polymer composites and calcium sulfate, to orthopedics and bone tissue repairs, as well as the progress made in biomimetic fabrication of injectable bone repair materials.

  2. Influence of land mosaic composition and structure on patchy populations: the case of the water vole (Arvicola sapidus) in Mediterranean farmland.

    PubMed

    Pita, Ricardo; Mira, António; Beja, Pedro

    2013-01-01

    The ability of patchy populations to persist in human-dominated landscapes is often assessed using focal patch approaches, in which the local occurrence or abundance of a species is related to the properties of individual patches and the surrounding landscape context. However, useful additional insights could probably be gained through broader, mosaic-level approaches, whereby whole land mosaics with contrasting patch-network and matrix characteristics are the units of investigation. In this study we addressed this issue, analysing how the southern water vole (Arvicola sapidus) responds to variables describing patch-network and matrix properties within replicated Mediterranean farmland mosaics, across a gradient of agricultural intensification. Patch-network characteristics had a dominant effect, with the total amount of habitat positively influencing both the occurrence of water voles and the proportion of area occupied in land mosaics. The proportions of patches and area occupied by the species were positively influenced by mean patch size, and negatively so by patch isolation. Matrix effects were weak, although there was a tendency for a higher proportion of occupied patches in more intensive, irrigated agricultural landscapes, particularly during the dry season. In terms of conservation, results suggest that water voles may be able to cope well with, or even be favoured by, the on-going expansion of irrigated agriculture in Mediterranean dry-lands, provided that a number of patches of wet herbaceous vegetation are maintained within the farmland mosaic. Overall, our study suggests that the mosaic-level approach may provide a useful framework to understand the responses of patchy populations to land use change.

  3. Synthetic and degradable patches: an emerging solution for rotator cuff repair

    PubMed Central

    Hakimi, Osnat; Mouthuy, Pierre-Alexis; Carr, Andrew

    2013-01-01

    The use of rotator cuff augmentation has increased dramatically over the last 10 years in response to the high rate of failure observed after non-augmented surgery. However, although augmentations have been shown to reduce shoulder pain, there is no consensus or clear guideline as to what is the safest or most efficacious material. Current augmentations, either available commercially or in development, can be classified into three categories: non-degradable structures, extra cellular matrix (ECM)-based patches and degradable synthetic scaffolds. Non-degradable structures have excellent mechanical properties, but can cause problems of infection and loss of integrity in the long-term. ECM-based patches usually demonstrate excellent biological properties in vitro, but studies have highlighted complications in vivo due to poor mechanical support and to infection or inflammation. Degradable synthetic scaffolds represent the new generation of implants. It is proposed that a combination of good mechanical properties, active promotion of biological healing, low infection risk and bio-absorption are the ideal characteristics of an augmentation material. Among the materials with these features, those processed by electrospinning have shown great promis. However, their clinical effectiveness has yet to be proven and well conducted clinical trials are urgently required. PMID:23837794

  4. Lightning Strike Induced Damage Mechanisms of Carbon Fiber Composites

    NASA Astrophysics Data System (ADS)

    Kawakami, Hirohide

    Composite materials have a wide application in aerospace, automotive, and other transportation industries, because of the superior structural and weight performances. Since carbon fiber reinforced polymer composites possess a much lower electrical conductivity as compared to traditional metallic materials utilized for aircraft structures, serious concern about damage resistance/tolerance against lightning has been rising. Main task of this study is to clarify the lightning damage mechanism of carbon fiber reinforced epoxy polymer composites to help further development of lightning strike protection. The research on lightning damage to carbon fiber reinforced polymer composites is quite challenging, and there has been little study available until now. In order to tackle this issue, building block approach was employed. The research was started with the development of supporting technologies such as a current impulse generator to simulate a lightning strike in a laboratory. Then, fundamental electrical properties and fracture behavior of CFRPs exposed to high and low level current impulse were investigated using simple coupon specimens, followed by extensive parametric investigations in terms of different prepreg materials frequently used in aerospace industry, various stacking sequences, different lightning intensity, and lightning current waveforms. It revealed that the thermal resistance capability of polymer matrix was one of the most influential parameters on lightning damage resistance of CFRPs. Based on the experimental findings, the semi-empirical analysis model for predicting the extent of lightning damage was established. The model was fitted through experimental data to determine empirical parameters and, then, showed a good capability to provide reliable predictions for other test conditions and materials. Finally, structural element level lightning tests were performed to explore more practical situations. Specifically, filled-hole CFRP plates and patch-repaired CFRP plates were selected as structural elements likely to be susceptible to lightning event. This study forms a solid foundation for the understanding of lightning damage mechanism of CFRPs, and become an important first step toward building a practical damage prediction tool of lighting event.

  5. The Role of Airborne Proteins in Atopic Dermatitis

    PubMed Central

    Hostetler, Sarah Grim; Kaffenberger, Benjamin; Hostetler, Todd

    2010-01-01

    Atopic dermatitis is a common, chronic skin condition. A subpopulation of patients may have cutaneous exposure to common airborne proteins exacerbating their disease through direct proteolytic activity, direct activation of proteinase-activated receptor-2 itch receptors, and immunoglobulin E binding. The most common airborne proteins significant in atopic dermatitis include house dust mites, cockroach, pet dander, and multiple pollens. The literature on atopy patch testing, skin-prick testing, and specific IgE is mixed, with greater support for the use of atopy patch test. Patients with airborne proteins contributing to their disease typically have lesions predominately on air-exposed skin surfaces including the face, neck, and arms; a history of exacerbations after exposure to airborne proteins; severe disease resistant to conventional therapies; and concurrent asthma. Treatment strategies include airborne protein avoidance, removal of airborne proteins from the skin, and barrier repair. Further research is needed to establish the benefit of allergen-specific immunotherapy. PMID:20725535

  6. "It is about how the net looks": a qualitative study of perceptions and practices related to mosquito net care and repair in two districts in eastern Uganda.

    PubMed

    Scandurra, Leah; Acosta, Angela; Koenker, Hannah; Kibuuka, Daniel Musoke; Harvey, Steven

    2014-12-17

    Prolonging net durability has important implications for reducing both malaria transmission and the frequency of net replacement. Protective behaviour, such as net care and repair, offers promise for improving net integrity and durability. Given the potential cost-savings and public health benefit associated with extending the useful life of long-lasting insecticidal nets (LLINs), prevention and mitigation of damage will become ever more critical to ensuring adequate net coverage at the population level. A qualitative assessment was conducted in two districts in central eastern Uganda in September 2013. Data on household net care and repair behaviour, attitudes and practices were collected from 30 respondents through in-depth interviews (IDIs), observations, photos, and video to gather an in-depth understanding of these behaviours. Net damage was common and the most cited causes were children and rodents. Responses revealed strong social norms about net cleanliness and aesthetics, and strong expectations that others should care for and repair their own nets. Respondents were receptive and able to repair nets, though longer-term repair methods, such as sewing and patching, were not as commonly reported or observed. Self-reported behaviour was not always consistent with observed or demonstrated behaviour, revealing potential misconceptions and the need for clear and consistent net care and repair messaging. Respondents considered both aesthetics and malaria protection important when deciding whether, when, and how to care for and repair nets. BCC should continue to emphasize the importance of maintaining net integrity for malaria prevention purposes as well as for maintaining aesthetic appeal. Additional research is needed, particularly surrounding washing, drying, daily storage routines, and gender roles in care and repair, in order to understand the complexity of these behaviours, and refine existing or develop new behaviour change communication (BCC) messages for net care and repair.

  7. Dexpanthenol enhances skin barrier repair and reduces inflammation after sodium lauryl sulphate-induced irritation.

    PubMed

    Proksch, E; Nissen, H P

    2002-12-01

    Dexpanthenol-containing creams have been widely used for treatment of lesions (superficial wounds) of the skin and mucous membranes. Dexpanthenol is converted in tissues to pantothenic acid, a component of coenzyme A. Coenzyme A catalyses early steps in the synthesis of fatty acids and sphingolipids which are of crucial importance for stratum corneum lipid bilayers and cell membrane integrity. In the present study, the effects were examined of a dexpanthenol-containing cream on skin barrier repair, stratum corneum hydration, skin roughness, and inflammation after sodium lauryl sulphate (SLS)-induced irritation. Irritation was induced by application of SLS in patch test chambers. The dexpanthenol-contaming cream or the vehicle were applied twice daily and barrier repair, hydration, roughness, and inflammation of the skin were determined by using biophysical methods. Significantly accelerated skin barrier repair was found in treatments with the dexpanthenol-containing cream (verum) compared with vehicle-treated (placebo) or untreated skin. Both verum and placebo showed an increase in stratum corneum hydration, but significantly more so with the dexpanthenol-containing cream. Both creams reduced skin roughness, but again the verum was superior. The dexpanthenol-containing cream significantly reduced skin redness as a sign of inflammation in contrast to the vehicle, which produced no effect. Treatment with a dexpanthenol-containing cream showed significantly enhanced skin barrier repair and stratum corneum hydration, while reducing skin roughness and inflammation.

  8. Recent advances in aerospace composite NDE

    NASA Astrophysics Data System (ADS)

    Georgeson, Gary E.

    2002-06-01

    As the aerospace industry continues to advance the design and use of composite structure, the NDE community faces the difficulties of trying to keep up. The challenges lie in manufacturing evaluation of the newest aerospace structures and materials and the in-service inspection and monitoring of damaged or aging composites. This paper provides examples of several promising NDI applications in the world of aerospace composites. Airborne (or non-contact) Ultrasonic Testing (UT) has been available for decades, but recently has generated new interest due to significant improvements in transducer design and low noise electronics. Boeing is developing inspection techniques for composite joints and core blankets using this technology. In-service inspection techniques for thick, multi-layer structures are also being advanced. One effective technique integrates the S-9 Sondicator, a traditional bond testing device, with Boeing's Mobile Automated Scanner (MAUS) platform. Composite patches have seen limited use on-aircraft, due, in part, to the difficulty of determining the quality of a bonded joint. A unique approach using Electronic Speckle Pattern Interferometry (ESPI) is showing promise as a bonded patch-inspection method. Other NDI techniques currently being developed for aerospace application are also briefly discussed.

  9. Ability of Impedance-Based Health Monitoring To Detect Structural Damage of Propulsion System Components Assessed

    NASA Technical Reports Server (NTRS)

    Martin, Richard E.; Gyekenyesi, Andrew L.; Sawicki, Jerzy T.; Baaklini, George Y.

    2005-01-01

    Impedance-based structural-health-monitoring uses piezoelectric (PZT) patches that are bonded onto or embedded in a structure. Each individual patch behaves as both an actuator of the surrounding structural area as well as a sensor of the structural response. The size of the excited area varies with the geometry and material composition of the structure, and an active patch is driven by a sinusoidal voltage sweep. When a PZT patch is subjected to an electric field, it produces a mechanical strain; and when it is stressed, it produces an electric charge. Since the patch is bonded to the structure, driving a patch deforms and vibrates the structure. The structure then produces a localized dynamic response. This structural system response is transferred back to the PZT patch, which in turn produces an electrical response. The electromechanical impedance method is based on the principle of electromechanical coupling between the active sensor and the structure, which allows researchers to assess local structural dynamics directly by interrogating a distributed sensor array. Because of mechanical coupling between the sensor and the host structure, this mechanical effect is picked up by the sensor and, through electromechanical coupling inside the active element, is reflected in electrical impedance measured at the sensor s terminals.

  10. Bioengineered porous composite curcumin/silk scaffolds for cartilage regeneration.

    PubMed

    Kim, Do Kyung; In Kim, Jeong; Sim, Bo Ra; Khang, Gilson

    2017-09-01

    Articular cartilage repair is a challenge due to its limited self-repair capacity. Cartilage tissue engineering supports to overcome following injuries or degenerative diseases. Herein, we fabricated the scaffold composed of curcumin and silk fibroin as an appropriate clinical replacement for defected cartilage. The scaffolds were designed to have adequate pore size and mechanical strength for cartilage repair. Cell proliferation, sulfated glycosaminoglycan (sGAG) content and mRNA expression analysis indicated that chondrocytes remained viable and showed its growth ability in the curcumin/silk scaffolds. Especially, in 1mg/ml curcumin/silk scaffold showed higher cell viability rate and extracellular matrix formation than other experimental groups. Furthermore, curcumin/silk scaffold showed its biocompatibility and favorable environment for cartilage repair after transplantation in vivo, as indicated in histological examination results. Overall, the functional composite curcumin/silk scaffold can be applied in cartilage tissue engineering and promising substrate for cartilage repair. Copyright © 2017. Published by Elsevier B.V.

  11. Self-repairing vanadium-zirconium composite conversion coating for aluminum alloys

    NASA Astrophysics Data System (ADS)

    Zhong, Xin; Wu, Xiaosong; Jia, Yuyu; Liu, Yali

    2013-09-01

    In this paper, new self-repairing vanadium-zirconium composite conversion coating was prepared and investigated by Electrochemical impedance spectra (EIS), Scanning electron microscope (SEM) and X-ray photoelectron spectroscopy (XPS), respectively. EIS results showed that V-Zr conversion coating with hydrogen peroxide modified (VZO) revealed an increasing corrosion resistance in corrosive media which meant a certain self-repairing effect. SEM comparison photos also disclosed that VZO treated with scratches was gradually ameliorated from the initial cracked configuration to fewer cracks and more fillers through an immersion of 3.5% NaCl solution. XPS results demonstrated that the content of vanadium on VZO increased and zirconium declined when immersed in the corrosive solution. This explained further that the self-repairing ability could be related to vanadium. From the above results, we inferred possible structures of VZO and proposed that self-repairing effect was achieved through a hydrolysis condensation polymerization process of vanadate in the localized corrosion area.

  12. Understanding how the shape and spatial distribution of ULVZs provides insight into their cause and to the nature of global-scale mantle convection

    NASA Astrophysics Data System (ADS)

    McNamara, Allen; Li, Mingming; Garnero, Ed; Marin, Nicole

    2017-04-01

    Seismic observations of the lower mantle infer multiple scales of compositional heterogeneity. The largest-scale heterogeneity, observed in seismic tomography models, is in the form of large, nearly antipodal regions referred to as the Large Low Shear Velocity Provinces (LLSVPs). In contrast, diffracted wave and core-reflection precursor seismic studies reveal small-scale Ultra Low Velocity Zones (ULVZs) at the base of the mantle that are almost two orders of magnitude smaller than the LLSVPs. We hypothesize that ULVZs provide insight into the nature of LLSVPs, and the LLSVPs, in turn, provide clues to the nature of global-scale mantle convection and compositional state. However, both LLSVPs and ULVZs are observations, and it remains unclear what is causing them. Here, we examine several related questions to aid in understanding their cause and the dynamical processes associated with them. Can we use seismic observations of ULVZ locations to differentiate whether they are caused by compositional heterogeneity or simply partial melting in otherwise normal mantle? Can we use the map-view shape of ULVZs to tell us about lowermost mantle flow directions and the temporal stability of these flow directions? Can the cross-sectional morphology of ULVZs tell us something about the viscosity difference between LLSVPs and background mantle? We performed geodynamical experiments to help answer these questions. We find that ULVZs caused by compositional heterogeneity preferentially form patch-like shapes along the margins of LLSVPs. Rounded patches indicate regions with long-lived stable mantle flow patterns, and linear patches indicate changing mantle flow patterns. Typically, these ULVZ patches have an asymmetrical cross-sectional shape; however, if LLSVPs have a larger grain-size than background mantle, their increased diffusion creep viscosity will act to make them more symmetrical. Alternatively, ULVZs caused simply by partial melting of normal mantle are preferentially located significantly inboard of LLSVP margins and have relatively symmetrical cross-sectional shapes. These results can prompt new seismic studies to better constrain the cause and dynamic significance of multi-scale compositional heterogeneity in the Earth's mantle.

  13. Improving aircraft composite inspections using optimized reference standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roach, D.; Dorrell, L.; Kollgaard, J.

    1998-10-01

    The rapidly increasing use of composites on commercial airplanes coupled with the potential for economic savings associated with their use in aircraft structures means that the demand for composite materials technology will continue to increase. Inspecting these composite structures is a critical element in assuring this continued airworthiness. The FAA`s Airworthiness Assurance NDI Validation Center, in conjunction with the Commercial Aircraft Composite Repair committee, is developing a set of composite reference standards to be used in NDT equipment calibration for accomplishment of damage assessment and post-repair inspection of all commercial aircraft composites. In this program, a series of NDI testsmore » on a matrix of composite aircraft structures and prototype reference standards were completed in order to minimize the number of standards needed to carry out composite inspections on aircraft. Two tasks, related to composite laminates and non-metallic composite honeycomb configurations, were addressed.« less

  14. Corridors and some ecological and evolutionary consequences of connectivity.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orrock, John L

    2004-07-01

    Abstract - By connecting disjunct patches, corridors may offset the effects of fragmentation by promoting gene flow and population persistence. However, the ultimate effect of corridors on a focal species may hinge upon two considerations: how corridors may affect ecological interactions that impinge upon that species, and how corridors might affect the fixation of novel alleles that ultimately determine fitness and persistence. Using an experimental landscape, I show that corridor-mediated changes in patch shape change seed predation in connected and unconnected patches, and shift the behavior, abundance, and distribution of seed predators. Rodent seed predators removed more seeds in connectedmore » patches, arthropod seed predators removed more seeds in rectangular patches, and avian seed predation did not differ due to patch type. Rodent foraging was greater in the interior of connected patches because changes in patch shape influenced risk perceived by rodents while foraging. Ant communities were also affected by changes in patch shape caused by corridors, rather than corridor effects per se. The distribution and abundance of ants differed among edge-rich areas (corridors and wings), edges, and the patch interior. In rectangular patches, fire ants (Solenopsis spp.) had negative impacts on other ant species. By changing the activity of rodents, and the composition of ant communities, corridors may have important impacts on seeds. Bird-dispersed seeds may benefit from increased dispersal among connected patches, but connected patches also have greater predation risk. Using a simulation model, I demonstrate that gene flow between a stable population and a population that experiences local extinction or a reduction in size (e.g. due to natural or anthropogenic disturbance) can dramatically affect fixation of alleles in the stable population. Alone or in concert, frequent disturbance, high rates of movement, and low habitat quality make it more likely that connectivity-mediated fixation will promote fixation of harmful alleles and reduce fixation of beneficial alleles.« less

  15. Preliminary inventory and classification of indigenous afromontane forests on the Blyde River Canyon Nature Reserve, Mpumalanga, South Africa

    PubMed Central

    Lötter, Mervyn C; Beck, Hans T

    2004-01-01

    Background Mixed evergreen forests form the smallest, most widely distributed and fragmented biome in southern Africa. Within South Africa, 44% of this vegetation type has been transformed. Afromontane forest only covers 0.56 % of South Africa, yet it contains 5.35% of South Africa's plant species. Prior to this investigation of the indigenous forests on the Blyde River Canyon Nature Reserve (BRCNR), very little was known about the size, floristic composition and conservation status of the forest biome conserved within the reserve. We report here an inventory of the forest size, fragmentation, species composition and the basic floristic communities along environmental gradients. Results A total of 2111 ha of forest occurs on Blyde River Canyon Nature Reserve. The forest is fragmented, with a total of 60 forest patches recorded, varying from 0.21 ha to 567 ha in size. On average, patch size was 23 ha. Two forest communities – high altitude moist afromontane forest and low altitude dry afromontane forest – are identified. Sub-communities are recognized based on canopy development and slope, respectively. An altitudinal gradient accounts for most of the variation within the forest communities. Conclusion BRCNR has a fragmented network of small forest patches that together make up 7.3% of the reserve's surface area. These forest patches host a variety of forest-dependent trees, including some species considered rare, insufficiently known, or listed under the Red Data List of South African Plants. The fragmented nature of the relatively small forest patches accentuates the need for careful fire management and stringent alien plant control. PMID:15287991

  16. Effect of Technological Tensioning on the Efficiency of Reinforcement of Pipelines with Composite Bands

    NASA Astrophysics Data System (ADS)

    Barkanov, E.; Beschetnikov, D.; Lvov, G.

    2015-01-01

    A mathematical model for the contact interaction of a cylindrical pipe with a composite band during its repair is constructed. A system of governing equations of the contact problem is formulated by using the Timoshenko theory of shells. An analysis of possible solutions is carried out for various combinations of geometric and elastic properties of shells. The possibility of pretension of a prepreg in order to improve the efficiency of repair is considered. The numerical results obtained allow one to establish the desired level of pretension for various repair situations.

  17. Effect of Transplanting Various Concentrations of a Composite of Human Umbilical Cord Blood-Derived Mesenchymal Stem Cells and Hyaluronic Acid Hydrogel on Articular Cartilage Repair in a Rabbit Model

    PubMed Central

    Ha, Chul-Won; Kim, Jin-A; Rhim, Ji-Heon; Park, Yong-Geun; Chung, Jun Young; Lee, Han-Jun

    2016-01-01

    Background Mesenchymal stem cells (MSCs) are known to have therapeutic potential for cartilage repair. However, the optimal concentration of MSCs for cartilage repair remains unclear. Therefore, we aimed to explore the feasibility of cartilage repair by human umbilical cord blood-derived MSCs (hUCB-MSCs) and to determine the optimal concentrations of the MSCs in a rabbit model. Methods Osteochondral defects were created in the trochlear groove of femur in 55 rabbits. Four experimental groups (11 rabbits/group) were treated by transplanting the composite of hUCB-MSCs and HA with various MSCs concentrations (0.1, 0.5, 1.0, and 1.5 x 107 cells/ml). One control group was left untreated. At 4, 8, and 16 weeks post-transplantation, the degree of cartilage repair was evaluated grossly and histologically. Findings Overall, transplanting hUCB-MSCs and HA hydrogel resulted in cartilage repair tissue with better quality than the control without transplantation (P = 0.015 in 0.1, P = 0.004 in 0.5, P = 0.004 in 1.0, P = 0.132 in 1.5 x 107 cells/ml). Interestingly, high cell concentration of hUCB-MSCs (1.5×107 cells/ml) was inferior to low cell concentrations (0.1, 0.5, and 1.0 x 107 cells/ml) in cartilage repair (P = 0.394,P = 0.041, P = 0.699, respectively). The 0.5 x 107 cells/ml group showed the highest cartilage repair score at 4, 8 and 16 weeks post transplantation, and followed by 0.1x107 cells/ml group or 1.0 x 107 cell/ml group. Conclusions The results of this study suggest that transplantation of the composite of hUCB-MSCs and HA is beneficial for cartilage repair. In addition, this study shows that optimal MSC concentration needs to be determined for better cartilage repair. PMID:27824874

  18. Effect of Transplanting Various Concentrations of a Composite of Human Umbilical Cord Blood-Derived Mesenchymal Stem Cells and Hyaluronic Acid Hydrogel on Articular Cartilage Repair in a Rabbit Model.

    PubMed

    Park, Yong-Beom; Ha, Chul-Won; Kim, Jin-A; Rhim, Ji-Heon; Park, Yong-Geun; Chung, Jun Young; Lee, Han-Jun

    2016-01-01

    Mesenchymal stem cells (MSCs) are known to have therapeutic potential for cartilage repair. However, the optimal concentration of MSCs for cartilage repair remains unclear. Therefore, we aimed to explore the feasibility of cartilage repair by human umbilical cord blood-derived MSCs (hUCB-MSCs) and to determine the optimal concentrations of the MSCs in a rabbit model. Osteochondral defects were created in the trochlear groove of femur in 55 rabbits. Four experimental groups (11 rabbits/group) were treated by transplanting the composite of hUCB-MSCs and HA with various MSCs concentrations (0.1, 0.5, 1.0, and 1.5 x 107 cells/ml). One control group was left untreated. At 4, 8, and 16 weeks post-transplantation, the degree of cartilage repair was evaluated grossly and histologically. Overall, transplanting hUCB-MSCs and HA hydrogel resulted in cartilage repair tissue with better quality than the control without transplantation (P = 0.015 in 0.1, P = 0.004 in 0.5, P = 0.004 in 1.0, P = 0.132 in 1.5 x 107 cells/ml). Interestingly, high cell concentration of hUCB-MSCs (1.5×107 cells/ml) was inferior to low cell concentrations (0.1, 0.5, and 1.0 x 107 cells/ml) in cartilage repair (P = 0.394,P = 0.041, P = 0.699, respectively). The 0.5 x 107 cells/ml group showed the highest cartilage repair score at 4, 8 and 16 weeks post transplantation, and followed by 0.1x107 cells/ml group or 1.0 x 107 cell/ml group. The results of this study suggest that transplantation of the composite of hUCB-MSCs and HA is beneficial for cartilage repair. In addition, this study shows that optimal MSC concentration needs to be determined for better cartilage repair.

  19. New Variable Porosity Flow Diverter (VPOD) Stent Design for Treatment of Cerebrovascular Aneurysms

    PubMed Central

    Ionita, Ciprian; Baier, Robert; Rudin, Stephen

    2012-01-01

    Using flow diverting Stents for intracranial aneurysm repair has been an area of recent active research. While current commercial flow diverting stents rely on a dense mesh of braided coils for flow diversion, our group has been developing a method to selectively occlude the aneurysm neck, without endangering nearby perforator vessels. In this paper, we present a new method of fabricating the low porosity patch, a key element of such asymmetric vascular stents (AVS). PMID:22254507

  20. A specialized face-processing model inspired by the organization of monkey face patches explains several face-specific phenomena observed in humans.

    PubMed

    Farzmahdi, Amirhossein; Rajaei, Karim; Ghodrati, Masoud; Ebrahimpour, Reza; Khaligh-Razavi, Seyed-Mahdi

    2016-04-26

    Converging reports indicate that face images are processed through specialized neural networks in the brain -i.e. face patches in monkeys and the fusiform face area (FFA) in humans. These studies were designed to find out how faces are processed in visual system compared to other objects. Yet, the underlying mechanism of face processing is not completely revealed. Here, we show that a hierarchical computational model, inspired by electrophysiological evidence on face processing in primates, is able to generate representational properties similar to those observed in monkey face patches (posterior, middle and anterior patches). Since the most important goal of sensory neuroscience is linking the neural responses with behavioral outputs, we test whether the proposed model, which is designed to account for neural responses in monkey face patches, is also able to predict well-documented behavioral face phenomena observed in humans. We show that the proposed model satisfies several cognitive face effects such as: composite face effect and the idea of canonical face views. Our model provides insights about the underlying computations that transfer visual information from posterior to anterior face patches.

  1. A specialized face-processing model inspired by the organization of monkey face patches explains several face-specific phenomena observed in humans

    PubMed Central

    Farzmahdi, Amirhossein; Rajaei, Karim; Ghodrati, Masoud; Ebrahimpour, Reza; Khaligh-Razavi, Seyed-Mahdi

    2016-01-01

    Converging reports indicate that face images are processed through specialized neural networks in the brain –i.e. face patches in monkeys and the fusiform face area (FFA) in humans. These studies were designed to find out how faces are processed in visual system compared to other objects. Yet, the underlying mechanism of face processing is not completely revealed. Here, we show that a hierarchical computational model, inspired by electrophysiological evidence on face processing in primates, is able to generate representational properties similar to those observed in monkey face patches (posterior, middle and anterior patches). Since the most important goal of sensory neuroscience is linking the neural responses with behavioral outputs, we test whether the proposed model, which is designed to account for neural responses in monkey face patches, is also able to predict well-documented behavioral face phenomena observed in humans. We show that the proposed model satisfies several cognitive face effects such as: composite face effect and the idea of canonical face views. Our model provides insights about the underlying computations that transfer visual information from posterior to anterior face patches. PMID:27113635

  2. Aortic root repair for thoracic aorta false aneurysm following Bentall procedure.

    PubMed

    Kumar, Sanjay; Jones, Steve; Sivananthan, U M; McGoldrick, J P

    2008-08-01

    The Bentall procedure for aortic root replacement in Marfan's syndrome is safe and durable. We describe successful repair of periprosthetic valvular leak, 12 years following Bentall repair with composite graft. The aim of this report is to analyse and evaluate technical factors leading to this unusual occurrence.

  3. Bond strength of the porcelain repair system to all-ceramic copings and porcelain.

    PubMed

    Lee, Sang J; Cheong, Chan Wook; Wright, Robert F; Chang, Brian M

    2014-02-01

    The purpose of this study was to investigate the shear bond strength of the porcelain repair system on alumina and zirconia core ceramics, comparing this strength with that of veneering porcelain. Veneering ceramic (n = 12), alumina core (n = 24), and zirconia core (n = 24) blocks measuring 10 × 5 × 5 mm(3) were fabricated. Veneering ceramic blocks were used as the control. Alumina and zirconia core blocks were divided into 2 groups (n = 12 each), and a slot (2 × 2 × 4 mm(3)) filled with veneering ceramics was prepared into one of the alumina and zirconia core groups (n = 12). Followed by surface treatments of micro-abrasion with 30 μm alumina particles, etching with 35% phosphoric acid and silane primer and bond, composite resin blocks (2 × 2 × 2 mm(3)) were built up and light polymerized onto the treated surfaces by 3 configurations: (a) composite blocks bonded onto veneering ceramic surface alone, (b) composite blocks bonded onto alumina core or zirconia core surfaces, (c) a 50% surface area of the composite blocks bonded to veneering ceramics and the other 50% surface area of the composite blocks to alumina core or zirconia core surfaces. The shear bond strength of the composite to each specimen was tested by a universal testing machine at a 0.5 mm/min crosshead speed. The shear bond strength was analyzed by unpaired t-tests for within the configuration groups and ANOVA for among the different configuration groups. When the mean shear bond strength was compared within groups of the same configuration, there were no statistically significant differences. Comparison of the shear bond strength among groups of different configurations revealed statistically significant differences. The mean shear bond strength of composite onto 100% veneering ceramic surface and composite onto 50% veneering 50% all-ceramic cores was statistically higher than that of composite onto 100% all-ceramic cores; however, the differences of the shear bond strength of composite bonded only onto the veneering ceramic surface were not statistically significant from those of 50% surface area of composite bonded onto all-ceramic cores. No statistically significant differences in the bond strength of a porcelain repair system to alumina and zirconia copings were observed. Increasing the surface of veneering ceramics to a porcelain repair system improved the repair material's bond strength. © 2013 by the American College of Prosthodontists.

  4. Decellularized material as scaffolds for tissue engineering studies in long gap esophageal atresia.

    PubMed

    Lee, Esmond; Milan, Anna; Urbani, Luca; De Coppi, Paolo; Lowdell, Mark W

    2017-05-01

    Esophageal atresia refers to an anomaly in foetal development in which the esophagus terminates in a blind end. Whilst surgical correction is achievable in most patients, when a long gap is present it still represents a major challenge associated with higher morbidity and mortality. In this context, tissue engineering could represent a successful alternative to restore oesophageal function and structure. Naturally derived biomaterials made of decellularized tissues retain native extracellular matrix architecture and composition, providing a suitable bed for the anchorage and growth of relevant cell types. Areas covered: This review outlines the various strategies and challenges in esophageal tissue engineering, highlighting the evolution of ideas in the development of decellularized scaffolds for clinical use. It explores the interplay between clinical needs, ethical dilemmas, and manufacturing challenges in the development of a tissue engineered decellularized scaffold for oesophageal atresia. Expert opinion: Current progress on oesophageal tissue engineering has enabled effective repair of patch defects, whilst the development of a full circumferential construct remains a challenge. Despite the different approaches available and the improvements achieved, a gold standard for fully functional tissue engineered oesophageal constructs has not been defined yet.

  5. Shear Bond Strength of Repair Systems to New CAD/CAM Restorative Materials.

    PubMed

    Üstün, Özlem; Büyükhatipoğlu, Işıl Keçik; Seçilmiş, Aslı

    2016-11-23

    To evaluate the bond strength of repair systems (Ceramic Repair, Clearfil Repair) to computer-aided design/computer-assisted machining (CAD/CAM) restorative materials (IPS e.max CAD, Vita Suprinity, Vita Enamic, Lava Ultimate). Thermally aged CAD/CAM restorative material specimens (5000 cycles between 5°C and 55°C) were randomly divided into two groups according to the repair system: Ceramic Repair (37% phosphoric acid + Monobond-S + Heliobond + Tetric N Ceram) or Clearfil Repair (40% phosphoric acid + mixture of Clearfil Porcelain Bond Activator and Clearfil SE Bond Primer + Clearfil SE Bond + Filtek Z250). The resin composite was light-cured on conditioned specimens. All specimens were stored in distilled water at 37°C for 24 hours and then additionally aged for 5000 thermal cycles. The shear bond strength test was performed using a universal testing machine (0.5 mm/min). Two-way ANOVA was used to detect significance differences according to the CAD/CAM material and composite repair system factors. Subgroup analyses were conducted using the least significant difference post-hoc test. The results of two-way ANOVA indicated that bond strength values varied according to the restorative materials (p < 0.05). No significant differences were observed between the CAD/CAM restorative materials (p > 0.05), except in the Vita Suprinity group (p < 0.05). Moreover, no differences were observed between the repair systems. Both the Clearfil and Ceramic repair systems used in the study allow for successful repairs. © 2016 by the American College of Prosthodontists.

  6. Landscape composition and configuration in the central highlands of Ethiopia.

    PubMed

    Tolessa, Terefe; Senbeta, Feyera; Kidane, Moges

    2016-10-01

    Landscape dynamics are common phenomenon in the human-dominated environments whereby it can be observed that the composition and configuration between landscape elements change over time. This dynamism brings about habitat loss and fragmentation that can greatly alter ecosystem services at patch, class, and landscape levels. We conducted a study to examine composition and configuration of forested landscape in the central highlands of Ethiopia using satellite images of over a period of four decades, and FRAGSTAT raster dataset was used to analyze fragmentation. Our result showed five land use/land cover (LULC) types in the study area. Cultivated land and settlement land increased at the expense of forestland, shrubland, and grassland. Fragmentation analysis showed the number of patches increased for all LULC types, indicating the level of fragmentation and interspersion. Juxtaposition increased for shrubland, grassland, and cultivated lands and decreased for settlement and forestland resulting in the fragmentation and isolation of patches. The study of LULC along with fragmentation at the landscape level can help improve our understanding of the pace at which conversion of landscape elements is happening and the impacts on ecosystem services as studies of LULC are courser in nature and would not show how each land use is reducing in size, proximity and shape among other things that determine ecosystem services. Such type of studies in rural landscapes are very vital to consider appropriate land management policies for the landscape level by taking into account the interaction between each element for sustainable development. We recommend land managers, conservationists, and land owners for observing the roles of each patch in the matrix to maximize the benefits than focusing on a single element.

  7. Interfacial damage identification of steel and concrete composite beams based on piezoceramic wave method.

    PubMed

    Yan, Shi; Dai, Yong; Zhao, Putian; Liu, Weiling

    2018-01-01

    Steel-concrete composite structures are playing an increasingly important role in economic construction because of a series of advantages of great stiffness, good seismic performance, steel material saving, cost efficiency, convenient construction, etc. However, in service process, due to the long-term effects of environmental impacts and dynamic loading, interfaces of a composite structure might generate debonding cracks, relative slips or separations, and so on, lowering the composite effect of the composite structure. In this paper, the piezoceramics (PZT) are used as transducers to perform experiments on interface debonding slips and separations of composite beams, respectively, aimed at proposing an interface damage identification model and a relevant damage detection innovation method based on PZT wave technology. One part of various PZT patches was embedded in concrete as "smart aggregates," and another part of the PZT patches was pasted on the surface of the steel beam flange, forming a sensor array. A push-out test for four specimens was carried out and experimental results showed that, under the action of the external loading, the received signal amplitudes will increasingly decrease with increase of debonding slips along the interface. The proposed signal energy-based interface damage detection algorithm is highly efficient in surface state evaluations of composite beams.

  8. Induction and differentiation of human induced pluripotent stem cells into functional cardiomyocytes on a compartmented monolayer of gelatin nanofibers

    NASA Astrophysics Data System (ADS)

    Tang, Yadong; Liu, Li; Li, Junjun; Yu, Leqian; Wang, Li; Shi, Jian; Chen, Yong

    2016-07-01

    Extensive efforts have been devoted to develop new substrates for culture and differentiation of human induced pluripotent stem cells (hiPSCs) toward cardiac cell-based assays. A more exciting prospect is the construction of cardiac tissue for robust drug screening and cardiac tissue repairing. Here, we developed a patch method by electrospinning and crosslinking of monolayer gelatin nanofibers on a honeycomb frame made of poly(ethylene glycol) diacrylate (PEGDA). The monolayer of the nanofibrous structure can support cells with minimal exogenous contact and a maximal efficiency of cell-medium exchange whereas a single hiPSC colony can be uniformly formed in each of the honeycomb compartments. By modulating the treatment time of the ROCK inhibitor Y-27632, the shape of the hiPSC colony could be controlled from a flat layer to a hemisphere. Afterwards, the induction and differentiation of hiPSCs were achieved on the same patch, leading to a uniform cardiac layer with homogeneous contraction. This cardiac layer could then be used for extracellular recording with a commercial multi-electrode array, showing representative field potential waveforms of matured cardiac tissues with appropriate drug responses.Extensive efforts have been devoted to develop new substrates for culture and differentiation of human induced pluripotent stem cells (hiPSCs) toward cardiac cell-based assays. A more exciting prospect is the construction of cardiac tissue for robust drug screening and cardiac tissue repairing. Here, we developed a patch method by electrospinning and crosslinking of monolayer gelatin nanofibers on a honeycomb frame made of poly(ethylene glycol) diacrylate (PEGDA). The monolayer of the nanofibrous structure can support cells with minimal exogenous contact and a maximal efficiency of cell-medium exchange whereas a single hiPSC colony can be uniformly formed in each of the honeycomb compartments. By modulating the treatment time of the ROCK inhibitor Y-27632, the shape of the hiPSC colony could be controlled from a flat layer to a hemisphere. Afterwards, the induction and differentiation of hiPSCs were achieved on the same patch, leading to a uniform cardiac layer with homogeneous contraction. This cardiac layer could then be used for extracellular recording with a commercial multi-electrode array, showing representative field potential waveforms of matured cardiac tissues with appropriate drug responses. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr04545f

  9. Evidence of phyllosilicates in Wooly Patch, an altered rock encountered at West Spur, Columbia Hills, by the Spirit rover in Gusev crater, Mars

    USGS Publications Warehouse

    Wang, A.; Korotev, R.L.; Jolliff, B.L.; Haskin, L.A.; Crumpler, L.; Farrand, W. H.; Herkenhoff, K. E.; de Souza, Jr.; Kusack, A.G.; Hurowitz, J.A.; Tosca, N.J.

    2006-01-01

    On its traverse to Columbia Hills, the Mars Exploration Rover Spirit investigated an outcrop designated "Wooly Patch" that exhibited morphological, mineralogical, and geochemical characteristics at the extreme ends of ranges observed among rocks studied at West Spur, a westward projecting salient near the foot of the Columbia Hills, Gusev crater. The major-element composition and Fe-mineralogy, as determined by the Alpha-Particle X-ray Spectrometer and Mo??ssbauer Spectrometer, are inconsistent with any reasonable assemblage of basaltic minerals in that there is an excess of Si and Al. The combined data are best explained by the presence of 14-17% phyllosilicate minerals. Phyllosilicates that account for the composition and cation ratios include members of the kaolinite, serpentine, chlorite, and septechlorite groups. The potential existence of kaolinite-type Al-rich phyllosilicates within the Wooly Patch outcrop suggests a mildly acidic environment (pH 4-6) in the past and an open hydrologic system with good drainage conditions in the environment where these rocks were altered. Copyright 2006 by the American Geophysical Union.

  10. Anthropometric and body composition changes in smokers vs abstainers following an exercise-aided pharmacotherapy smoking cessation trial for women.

    PubMed

    Prapavessis, Harry; De Jesus, Stefanie; Fitzgeorge, Lyndsay; Rollo, Scott

    2018-06-07

    Post-cessation weight gain contributes to smoking relapse, especially for women. Furthermore, excess weight in the form of android or visceral fat is associated with metabolic health problems. For this study, a secondary analysis was conducted in 2015 to determine whether quitting status, achieved through a 14 week supervised exercise-aided nicotine replacement therapy (NRT) cessation program [Getting Physical on Cigarette Trial-2009 to 2013; Prapavessis, et al., 2016], affects anthropometric and body composition parameters in female smokers (N = 413, M age = 42.39 years). Anthropometric (weight and BMI) and body composition (% total body fat, % android fat, lean mass and visceral fat) indices were assessed at baseline and end of treatment. Smoking status was confirmed weekly from expired breath carbon monoxide. Adherence to exercise and NRT patch was calculated from the number of exercise sessions attended and patches worn to the number of exercise sessions offered and patches supplied, respectively. Factorial (smoking status) ANCOVAs controlling for baseline anthropometric and body composition parameters as well as adherence to exercise and NRT revealed significant differences in weight (p = .033; ɳ p 2  = 0.017) and BMI (p = .020; ɳ p 2  = 0.020) at week 14. This equated to abstainers weighing 1.26 kg more and having a 0.52 higher BMI than smokers. No significant differences were found for any of the body composition parameters at week 14 (ɳ p 2 range from 0.001-0.007). Abstainers gain modest weight compared to smokers. This weight gain is related to increases in lean mass and not total, android, or visceral fat. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Influence of Land Mosaic Composition and Structure on Patchy Populations: The Case of the Water Vole (Arvicola sapidus) in Mediterranean Farmland

    PubMed Central

    Pita, Ricardo; Mira, António; Beja, Pedro

    2013-01-01

    The ability of patchy populations to persist in human-dominated landscapes is often assessed using focal patch approaches, in which the local occurrence or abundance of a species is related to the properties of individual patches and the surrounding landscape context. However, useful additional insights could probably be gained through broader, mosaic-level approaches, whereby whole land mosaics with contrasting patch-network and matrix characteristics are the units of investigation. In this study we addressed this issue, analysing how the southern water vole (Arvicola sapidus) responds to variables describing patch-network and matrix properties within replicated Mediterranean farmland mosaics, across a gradient of agricultural intensification. Patch-network characteristics had a dominant effect, with the total amount of habitat positively influencing both the occurrence of water voles and the proportion of area occupied in land mosaics. The proportions of patches and area occupied by the species were positively influenced by mean patch size, and negatively so by patch isolation. Matrix effects were weak, although there was a tendency for a higher proportion of occupied patches in more intensive, irrigated agricultural landscapes, particularly during the dry season. In terms of conservation, results suggest that water voles may be able to cope well with, or even be favoured by, the on-going expansion of irrigated agriculture in Mediterranean dry-lands, provided that a number of patches of wet herbaceous vegetation are maintained within the farmland mosaic. Overall, our study suggests that the mosaic-level approach may provide a useful framework to understand the responses of patchy populations to land use change. PMID:23875014

  12. Composite scaffolds for osteochondral repair obtained by combination of additive manufacturing, leaching processes and hMSC-CM functionalization.

    PubMed

    Díaz Lantada, Andrés; Alarcón Iniesta, Hernán; García-Ruíz, Josefa Predestinación

    2016-02-01

    Articular repair is a relevant and challenging area for the emerging fields of tissue engineering and biofabrication. The need of significant gradients of properties, for the promotion of osteochondral repair, has led to the development of several families of composite biomaterials and scaffolds, using different effective approaches, although a perfect solution has not yet been found. In this study we present the design, modeling, rapid manufacturing and in vitro testing of a composite scaffold aimed at osteochondral repair. The presented composite scaffold stands out for having a functional gradient of density and stiffness in the bony phase, obtained in titanium by means of computer-aided design combined with additive manufacture using selective laser sintering. The chondral phase is obtained by sugar leaching, using a PDMS matrix and sugar as porogen, and is joined to the bony phase during the polymerization of PDMS, therefore avoiding the use of supporting adhesives or additional intermediate layers. The mechanical performance of the construct is biomimetic and the stiffness values of the bony and chondral phases can be tuned to the desired applications, by means of controlled modifications of different parameters. A human mesenchymal stem cell (h-MSC) conditioned medium (CM) is used for improving scaffold response. Cell culture results provide relevant information regarding the viability of the composite scaffolds used. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Relationships of habitat patch size to predator community and survival of duck nests

    USGS Publications Warehouse

    Sovada, M.A.; Zicus, M.C.; Greenwood, R.J.; Rave, D.P.; Newton, W.E.; Woodward, R.O.; Beiser, J.A.

    2000-01-01

    We studied duck nest success and predator community composition in relation to size of discrete patches of nesting cover in the Prairie Pothole Region (PPR) of the United States in 1993-95. We focused on nests in uplands that were seeded to perennial grasses and forbs and enrolled in the Conservation Reserve Program (CRP) in Minnesota, North Dakota, and South Dakota. We estimated daily survival rates (DSRs) of upland duck nests and indices of activity for red foxes (Vulpes vulpes), coyotes (Canis latrans), American badgers (Taxidea taxus), striped skunks (Mephitis mephitis), and Franklin's ground squirrels (Spermophilus franklinii), and related these variables to habitat patch size. The effect of patch size (small vs. large) on estimated annual mean DSR was dependent on date of nest initiation (early vs. late) and year. Examination of within-year comparisons for early and late nests suggested that DSR was generally greater in larger habitat patches. Activity indices for the 5 mammalian nest predators were influenced differently by year, location, and patch size. Activity indices of the red fox were greatest in small patches. Coyote indices were the most inconsistent, demonstrating a year X location X patch size interaction. Activity indices of the striped skunk and American badger varied only among years. Franklin's ground squirrel indices were affected by study area location, with higher indices in the southeast than the northwest. Red fox activity was weakly correlated with that of the striped skunk and coyote. Although a positive relationship between habitat patch size and nest success probably exists, we believe the experiment to fully test this hypothesis will continue to be elusive.

  14. Making on-orbit structural repairs to Space Station

    NASA Technical Reports Server (NTRS)

    Haber, Harry S.; Quinn, Alberta

    1989-01-01

    One of the key factors dictating the safety and durability of the proposed U.S. Space Station is the ability to repair structural damage while remaining in orbit. Consequently, studies are conducted to identify the engineering problems associated with accomplishing structural repairs on orbit, due to zero gravity environment and exposure to extreme temperature variations. There are predominant forms of structural failure, depending on the metallic or composite material involved. Aluminum is the primary metallic material used in space vehicle applications. Welding processes on aluminum alloy structures were tested, resulting in final selection of electron beam welding as the primary technique for metallic material repair in Space. Several composite structure repair processes were bench-tested to define their applicability to on-orbit EVA requirements: induction heating prevailed. One of the unique problems identified as inherent in the on-orbit repair process is that of debris containment. The Maintenance Work Station concept provides means to prevent module contamination from repair debris and ensure the creation of a facility for crew members to work easily in a microgravity environment. Different technologies were also examined for application to EVA repair activities, and the concept selected was a spring-loaded, collapsible, box-like Debris Containement and Collection Device with incorporated fold-down tool boards and handholes in the front panel.

  15. Evidence for a Role of FEN1 in Maintaining Mitochondrial DNA Integrity

    PubMed Central

    Kalifa, Lidza; Beutner, Gisela; Phadnis, Naina; Sheu, Shey-Shing; Sia, Elaine A.

    2009-01-01

    Although the nuclear processes responsible for genomic DNA replication and repair are well characterized, the pathways involved in mitochondrial DNA (mtDNA) replication and repair remain unclear. DNA repair has been identified as being particularly important within the mitochondrial compartment due to the organelle’s high propensity to accumulate oxidative DNA damage. It has been postulated that continual accumulation of mtDNA damage and subsequent mutagenesis may function in cellular aging. Mitochondrial base excision repair (mtBER) plays a major role in combating mtDNA oxidative damage; however, the proteins involved in mtBER have yet to be fully characterized. It has been established that during nuclear long-patch (LP) BER, FEN1 is responsible for cleavage of 5′ flap structures generated during DNA synthesis. Furthermore, removal of 5′ flaps has been observed in mitochondrial extracts of mammalian cell lines; yet, the mitochondrial localization of FEN1 has not been clearly demonstrated. In this study, we analyzed the effects of deleting the yeast FEN1 homolog, RAD27, on mtDNA stability in Saccharomyces cerevisiae. Our findings demonstrate that Rad27p/FEN1 is localized in the mitochondrial compartment of both yeast and mice and that Rad27p has a significant role in maintaining mtDNA integrity. PMID:19699691

  16. [Advances in research and application of beta-tricalcium phosphate, collagen and beta-tricalcium phosphate/collagen composite in bone tissue engineering].

    PubMed

    Han, Xiang-Yong; Fu, Yuan-Fei; Zhang, Fu-Qiang

    2007-02-01

    Bone defects in oral and maxillofacial region was a common problem. To repair the defect, bone grafts including autograft, allograft and artificial bone graft were used in clinic despite of their disadvantages. Nowadays, bone tissue engineering has become a commonly used method to repair bone defect. This paper reviewed the application of beta-TCP, collagen and beta-TCP/collagen composite in bone tissue engineering. It was concluded that beta-TCP/collagen composite was a promising materials in bone tissue engineering.

  17. Evaluation of porous gradient hydroxyapatite/zirconia composites for repair of lumbar vertebra defect in dogs.

    PubMed

    Shao, Rong-Xue; Quan, Ren-Fu; Huang, Xiao-Long; Wang, Tuo; Xie, Shang-Ju; Gao, Huan-Huan; Wei, Xi-Cheng; Yang, Di-Sheng

    2016-04-01

    To evaluate the effects of porous gradient composites with hydroxyapatite/zirconia and autologous iliac in repair of lumbar vertebra body defects in dogs. (1) New porous gradient hydroxyapatite/zirconia composites were prepared using foam immersion, gradient compound and high temperature sintering; (2) A total of 18 adult beagle dogs, aged five to eight months and weighted 10-13 kg, were randomly assigned into two subgroups, which were implanted with new porous gradient hydroxyapatite/zirconia composites (subgroup A in 12) or autologous iliac bone (subgroup B in 6); (3) The post-operative data were analyzed and compared between the subgroups to repair the vertebral body defect by roentgenoscopy, morphology and biomechanics. The porosity of new porous gradient hydroxyapatite/zirconia composites is at 25 poles per inch, and the size of pores is at between 150 and 300 µm. The post-operative roentgenoscopy displayed that new-bone formation is increased gradually, and the interface between composites and host-bone becomes became blur, and the new-bone around the composites were integrated into host-bone at 24 weeks postoperatively in subgroup A. As to subgroup B, the resorption and restructure were found at six weeks after the surgery, and the graft-bone and host-bone have been integrated completely without obvious boundary at 24 weeks postoperatively. Histomorphologic study showed that the amount of bone within pores of the porous gradient hydroxyapatite/zirconia composites increased continuously with a prolonged implantation time, and that partial composites were degradated and replaced by new-bone trabeculae. There was no significant difference between subgroups (P > 0.05) in the ultimate compressive strengths. New porous gradient hydroxyapatite/zirconia composites can promote the repair of bony defect, and induce bone tissue to ingrow into the pores, which may be applied widely to the treatment of bony defect in the future. © The Author(s) 2016.

  18. Preclinical evaluation of the effect of the combined use of the Ethicon Securestrap® Open Absorbable Strap Fixation Device and Ethicon Physiomesh™ Open Flexible Composite Mesh Device on surgeon stress during ventral hernia repair

    PubMed Central

    Sutton, Nadia; MacDonald, Melinda H; Lombard, John; Ilie, Bodgan; Hinoul, Piet; Granger, Douglas A

    2018-01-01

    Aim To evaluate whether performing ventral hernia repairs using the Ethicon Physiomesh™ Open Flexible Composite Mesh Device in conjunction with the Ethicon Securestrap® Open Absorbable Strap Fixation Device reduces surgical time and surgeon stress levels, compared with traditional surgical repair methods. Methods To repair a simulated ventral incisional hernia, two surgeries were performed by eight experienced surgeons using a live porcine model. One procedure involved traditional suture methods and a flat mesh, and the other procedure involved a mechanical fixation device and a skirted flexible composite mesh. A Surgery Task Load Index questionnaire was administered before and after the procedure to establish the surgeons’ perceived stress levels, and saliva samples were collected before, during, and after the surgical procedures to assess the biologically expressed stress (cortisol and salivary alpha amylase) levels. Results For mechanical fixation using the Ethicon Physiomesh Open Flexible Composite Mesh Device in conjunction with the Ethicon Securestrap Open Absorbable Strap Fixation Device, surgeons reported a 46.2% reduction in perceived workload stress. There was also a lower physiological reactivity to the intraoperative experience and the total surgical procedure time was reduced by 60.3%. Conclusions This study provides preliminary findings suggesting that the combined use of a mechanical fixation device and a skirted flexible composite mesh in an open intraperitoneal onlay mesh repair has the potential to reduce surgeon stress. Additional studies are needed to determine whether a reduction in stress is observed in a clinical setting and, if so, confirm that this results in improved clinical outcomes. PMID:29296101

  19. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    PubMed

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  20. Early primary repair of tetralogy of fallot in neonates and infants less than four months of age.

    PubMed

    Tamesberger, Melanie I; Lechner, Evelyn; Mair, Rudolf; Hofer, Anna; Sames-Dolzer, Eva; Tulzer, Gerald

    2008-12-01

    The ideal age for correction of tetralogy of Fallot is still under discussion. The aim of this study was to analyze morbidity and mortality in patients who underwent early primary repair of tetralogy of Fallot at the age of less than 4 months and to assess whether neonates, who needed early repair within the first 4 weeks of life, faced an increased risk. From 1995 to 2006, 90 consecutive patients with tetralogy of Fallot and pulmonary stenosis underwent early primary repair. Patient charts were analyzed retrospectively for two groups: group A, 25 neonates younger than 28 days who needed early operation owing to duct-dependent pulmonary circulation or severe hypoxemia; and group B, 65 infants younger than 4 months of age who underwent elective early repair. There was no 30-day mortality; late mortality was 2% after a median follow-up time of 4.7 years. Seven of 88 patients (8%) needed reoperation and twelve of 88 patients (14%) needed reintervention. Groups A and B did not differ significantly in terms of intensive care unit stay, days of mechanical ventilation, overall hospital stay, major or minor complications, or reoperation. Significant differences were found in a more frequent use of a transannular patch (p = 0.045) and more reinterventions (p = 0.046) in group A. Early primary repair of tetralogy of Fallot can be performed safely and effectively in infants younger than 4 months of age and even in neonates younger than 28 days with duct-dependent pulmonary circulation or severe hypoxemia.

  1. Reduced repair capacity of a DNA clustered damage site comprised of 8-oxo-7,8-dihydro-2'-deoxyguanosine and 2-deoxyribonolactone results in an increased mutagenic potential of these lesions

    DOE PAGES

    Cunniffe, Siobhan; O’Neill, Peter; Greenberg, Marc M.; ...

    2014-04-01

    A signature of ionizing radiation is the induction of DNA clustered damaged sites. Non-double strand break (DSB) clustered damage has been shown to compromise the base excision repair pathway, extending the lifetimes of the lesions within the cluster, compared to isolated lesions. This increases the likelihood the lesions persist to replication and thus increasing the mutagenic potential of the lesions within the cluster. Lesions formed by ionizing radiation include 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodGuo) and 2-deoxyribonolactone (dL). dL poses an additional challenge to the cell as it is not repaired by the short-patch base excision repair pathway. Here we show recalcitrant dL repairmore » is reflected in mutations observed when DNA containing it and a proximal 8-oxodGuo is replicated in Escherichia coli. 8-oxodGuo in close proximity to dL on the opposing DNA strand results in an enhanced frequency of mutation of the lesions within the cluster and a 20 base sequence flanking the clustered damage site in an E. coli based plasmid assay. In vitro repair of a dL lesion is reduced when compared to the repair of an abasic (AP) site and a tetrahydrofuran (THF), and this is due mainly to a reduction in the activity of polymerase β, leading to retarded FEN1 and ligase 1 activities. This study has given insights in to the biological effects of clusters containing dL.« less

  2. Imprint of oaks on nitrogen availability and δ15N in California grassland-savanna: A case of enhanced N inputs?

    USGS Publications Warehouse

    Perakis, S.S.; Kellogg, C.H.

    2007-01-01

    Woody vegetation is distributed patchily in many arid and semi-arid ecosystems, where it is often associated with elevated nitrogen (N) pools and availability in islands of fertility. We measured N availability and δ15N in paired blue-oak versus annual grass dominated patches to characterize the causes and consequences of spatial variation in N dynamics of grassland-savanna in Sequoia-Kings Canyon National Park. We found significantly greater surface soil N pools (0–20 cm) in oak patches compared to adjacent grass areas across a 700 m elevation gradient from foothills to the savanna-forest boundary. N accumulation under oaks was associated with a 0.6‰ depletion in soil δ15N relative to grass patches. Results from a simple δ15N mass balance simulation model, constrained by surface soil N and δ15N measured in the field, suggest that the development of islands of N fertility under oaks can be traced primarily to enhanced N inputs. Net N mineralization and percent nitrification in laboratory incubations were consistently higher under oaks across a range of experimental soil moisture regimes, suggesting a scenario whereby greater N inputs to oak patches result in net N accumulation and enhanced N cycling, with a potential for greater nitrate loss as well. N concentrations of three common herbaceous annual plants were nearly 50% greater under oak than in adjacent grass patches, with community composition shifted towards more N-demanding species under oaks. We find that oaks imprint distinct N-rich islands of fertility that foster local feedback between soil N cycling, plant N uptake, and herbaceous community composition. Such patch-scale differences in N inputs and plant–soil interactions increase biogeochemical heterogeneity in grassland-savanna ecosystems and may shape watershed-level responses to chronic N deposition.

  3. Repair Concepts as Design Constraints of a Stiffened Composite PRSEUS Panel

    NASA Technical Reports Server (NTRS)

    Przekop, Adam

    2012-01-01

    A design and analysis of a repair concept applicable to a stiffened thin-skin composite panel based on the Pultruded Rod Stitched Efficient Unitized Structure is presented. The concept is a bolted repair using metal components, so that it can easily be applied in the operational environment. The damage scenario considered is a midbay-to-midbay saw-cut with a severed stiffener, flange and skin. In a previous study several repair configurations were explored and their feasibility confirmed but refinement was needed. The present study revisits the problem under recently revised design requirements and broadens the suite of loading conditions considered. The repair assembly design is based on the critical tension loading condition and subsequently its robustness is verified for a pressure loading case. High fidelity modeling techniques such as mesh-independent definition of compliant fasteners, elastic-plastic material properties for metal parts and geometrically nonlinear solutions are utilized in the finite element analysis. The best repair design is introduced, its analysis results are presented and factors influencing the design are assessed and discussed.

  4. Induction of broad immunity by thermostabilised vaccines incorporated in dissolvable microneedles using novel fabrication methods.

    PubMed

    Vrdoljak, Anto; Allen, Evin A; Ferrara, Francesca; Temperton, Nigel J; Crean, Abina M; Moore, Anne C

    2016-03-10

    Dissolvable microneedle (DMN) patches for immunization have multiple benefits, including vaccine stability and ease-of-use. However, conventional DMN fabrication methods have several drawbacks. Here we describe a novel, microfluidic, drop dispensing-based dissolvable microneedle production method that overcomes these issues. Uniquely, heterogeneous arrays, consisting of microneedles of diverse composition, can be easily produced on the same patch. Robustness of the process was demonstrated by incorporating and stabilizing adenovirus and MVA vaccines. Clinically-available trivalent inactivated influenza vaccine (TIV) in DMN patches is fully stable for greater than 6months at 40°C. Immunization using low dose TIV-loaded DMN patches induced significantly higher antibody responses compared to intramuscular-based immunization in mice. TIV-loaded patches also induced a broader, heterosubtypic neutralizing antibody response. By addressing issues that will be faced in large-scale fill-finish DMN fabrication processes and demonstrating superior thermostable characteristics and immunogenicity, this study progresses the translation of this microneedle platform to eventual clinical deployment. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Within-male melanin-based plumage and bill elaboration in male house sparrows.

    PubMed

    Václav, Radovan

    2006-12-01

    If there is a cost to producing a dark color patch, the size of a patch may not correspond with its pigment concentration. The plumage of male house sparrows represents a case of dark, melanin-based ornamentation, but also a case of neglecting the composite nature of dark signals in birds. Here, I investigated what kind of associations exist between the brightness, chroma, and hue of dark integumentary patches and the size of a secondary sexual trait, the bib, in male house sparrows. I found that males with a larger bib also had a darker bib and bill, and a more saturated bib, bill, epaulets, head crown, and breast than small-bibbed males. Male bib coloration in terms of brightness and chroma was more strongly related to bib size than the coloration of other integumentary patches. However, with respect to hue, only the hue of the bill and cheeks was related to bib size. My results indicate that size, brightness, and chroma of the bib, but also chroma of other deeply colored patches, convey redundant information about the signaler's quality in male house sparrows.

  6. Collagen-Platelet Composite Enhances Biomechanical and Histologic Healing of the Porcine Anterior Cruciate Ligament

    PubMed Central

    Joshi, Shilpa M.; Mastrangelo, Ashley N.; Magarian, Elise M.; Fleming, Braden C.; Murray, Martha M.

    2010-01-01

    Background The anterior cruciate ligament (ACL) fails to heal after traumatic rupture. Furthermore, large-animal models have recently shown that 1-month functional ACL healing is augmented after suture repair when a bioactive scaffold is placed in the tear site. Hypothesis At the time of suture repair, placement of a bioactive scaffold in the ACL wound site would improve the structural properties of the tissue. Study Design Controlled laboratory study. Methods Twenty-seven knees in immature pigs underwent ACL transection and suture repair. A collagen-platelet composite (CPC) was used to supplement the repair in 14 knees. Knees were harvested at 4 weeks, 6 weeks, and 3 months. Mechanical testing and histologic analysis were performed. Results The addition of a CPC to a suture repair resulted in improvements in yield load and linear stiffness of the repair tissue at 3 months, as well as a significant increase in cell density. A reduction in yield load and stiffness occurred at the 6-week time point in both groups, a phase when revascularization was noted. Conclusion The addition of a CPC to a suture repair enhanced the structural properties of the ACL, and the improvement was associated with increased cellularity within the healing ligament. Clinical Relevance The addition of a bioactive scaffold to the wound site improved the functional healing of the ACL after suture repair. The decreased repair strength during revascularization may indicate a need to protect the repair site through this period. PMID:19940313

  7. Evaluation of Repair Efficiency in Structures Made of Fibrous Polymer Composite Materials

    NASA Astrophysics Data System (ADS)

    Anoshkin, A. N.; Vil'deman, V. E.; Lobanov, D. S.; Chikhachev, A. I.

    2014-07-01

    Full-scale experimental investigations into the residual strength of structurally similar elements of acoustical panels after a local repair of defects, such as through breakdown, were conducted. Local repairs without using the vacuum technology were carried out. The technology of repair consists in removing and layer-bylayer replacing the damaged layers of material with repaired ones. For comparison, undamaged and repaired sandwich panel specimens were tested in tension and compression. The specimens were produced by serial technology from a VPS-33 fiberglass prepreg. Their deformation and fracture mechanisms are analyzed, and their loading diagrams are obtained.

  8. Percutaneous fetoscopic closure of large open spina bifida using a bilaminar skin substitute.

    PubMed

    Lapa Pedreira, Denise A; Acacio, Gregório L; Gonçalves, Rodrigo T; Sá, Renato Augusto M; Brandt, Reynaldo A; Chmait, Ramen; Kontopoulos, Eftichia; Quintero, Ruben A

    2018-01-04

    We have previously described our percutaneous fetoscopic technique for the treatment of open spina bifida (OSB). However, approximately 20-30% of OSB defects are too large to allow primary skin closure. We hereby describe a modification of our standard technique using a bilaminar skin substitute to allow closure of such large spinal defects. The aim of this study was to report our clinical experience with the use of a bilaminar skin substitute and a percutaneous fetoscopic technique for the prenatal closure of large spina bifida defects. Surgeries were performed between 24.0 and 28.9 gestational weeks under general anesthesia, using an entirely percutaneous fetoscopic approach with partial CO2 insufflation of the uterine cavity, as previously described. If there was enough skin to be sutured in the midline, only a biocellulose patch was placed over the placode. In cases where skin approximation was not possible, a bilaminar skin substitute (two layers: one silicone and one dermal matrix) was placed over the biocellulose. The surgical site was assessed at birth, and long-term follow-up was performed. Forty-seven consecutive fetuses underwent percutaneous fetoscopic OSB repair. Premature preterm rupture of membranes (PPROM) occurred in 38 (84%), and the mean gestational age at delivery was 32,8 + 2.5 weeks. A bilaminar skin substitute was required in 13 (29%), of which 5 was associated with myeloschisis. In all cases the skin substitute was found at the surgical site, at birth. In 3 (15%) of these cases, postnatal additional repair was needed. In the other 10 cases, the silicone layer detached spontaneously from the dermal matrix (average 25 days after birth), and the lesion healed by secondary-intention. Operating time was significantly longer in cases requiring the bilaminar skin substitute (additional 42 minutes). The subgroup with bilaminar skin substitute had similar PPROM rate and delivery gestational age compared to the one patch group. Complete reversal of hindbrain herniation occurred in 68% of the one patch and in 33% (p < 0.05) of the two patches group. In 4 cases there was no reversal and 3 of them were myeloschisis cases. Large OSB defects may be successfully treated in utero using a bilaminar skin substitute over a biocellulose patch through an entirely percutaneous approach. Although the operating time is longer, surgical outcomes are similar to cases closed primarily. Myeloschisis seems to have a worse prognosis then myelomeningocele cases. PPROM and preterm birth continue to be a challenge. Further experience is needed to assess the risks and benefits of this technique for management of large OSB defects. This article is protected by copyright. All rights reserved.

  9. Proceedings of the USAF Structural Integrity Program Conference Held in San Antonio, Texas on 2-6 December 1991

    DTIC Science & Technology

    1992-07-01

    NONDESTRUCTIVE INSPECTION Probabilistic Durability Evaluation of Alcoa 7050 Aluminum ............................... 305 Composite Repair of Aircraft Structures... Aluminum J.G. Burns, WLIFIBEC 0900-0930 Composite Repair of Aircraft Structures - The Australian Experience L. Molent, Aeronautical Research Laboratory...fatigue test articles consisted of a of 5 percent from the calculated airframe ratio of 2124-T851 aluminum specimen surrounded by 0.882, to preclude

  10. Self-Repairing Mechanism of MUF/Epoxy Microcapsules for Epoxy Material

    NASA Astrophysics Data System (ADS)

    Ni, Zhuo; Lin, Yuhao; Zhou, Xiaobo

    2017-12-01

    In this paper, a post curing reaction for the microcapsule/epoxy composite material and the conditions of thermal treatment for self-healing process were studied by differential scanning calorimetry (DSC). The condition of thermal treatment for post curing (60°C, 2 hours) was employed to fully cure the epoxy composite. Damage mechanism for the epoxy material was demonstrated via data simulation and three-point bending experiment for the stress distribution reveals that micro-cracks are more likely to be generated on the central region in stress concentration area of two constrained boundaries and the numbers of micro-cracks are reduced from the central area to the two ends of the material. Self-repairing performances of MUF microcapsule/epoxy composite materials were characterized using both destructive bending tests and non-destructive DMA measurements. Self-healing efficiencies of the composites embedded 2% and 5% microcapsule content measured by DMA are 101% and 104% respectively which are close to those results of 104% and 113% correspondingly measured by bending tests. Crack formation and development, core material releasing for MUF microcapsules and physiochemical process of the self-repairing were investigated by using OM, fluorescent technique and infrared microscope. These provide detailed evidences and important information on self-healing mechanism of the microcapsule/epoxy self-repairing material.

  11. Repair Bond Strength of Aged Resin Composite after Different Surface and Bonding Treatments

    PubMed Central

    Wendler, Michael; Belli, Renan; Panzer, Reinhard; Skibbe, Daniel; Petschelt, Anselm; Lohbauer, Ulrich

    2016-01-01

    The aim of this study was to compare the effect of different mechanical surface treatments and chemical bonding protocols on the tensile bond strength (TBS) of aged composite. Bar specimens were produced using a nanohybrid resin composite and aged in distilled water for 30 days. Different surface treatments (diamond bur, phosphoric acid, silane, and sandblasting with Al2O3 or CoJet Sand), as well as bonding protocols (Primer/Adhesive) were used prior to application of the repair composite. TBS of the specimens was measured and the results were analyzed using analysis of variance (ANOVA) and the Student–Newman–Keuls test (α = 0.05). Mechanically treated surfaces were characterized under SEM and by profilometry. The effect of water aging on the degree of conversion was measured by means of FTIR-ATR spectroscopy. An important increase in the degree of conversion was observed after aging. No significant differences in TBS were observed among the mechanical surface treatments, despite variations in surface roughness profiles. Phosphoric acid etching significantly improved repair bond strength values. The cohesive TBS of the material was only reached using resin bonding agents. Application of an intermediate bonding system plays a key role in achieving reliable repair bond strengths, whereas the kind of mechanical surface treatment appears to play a secondary role. PMID:28773669

  12. Selection of pipe repair methods.

    DOT National Transportation Integrated Search

    2013-06-01

    The objective of this research is to provide pipeline operators with testing procedures and : results of the performance of composite pipe repair methods and ultimately, improve their : selection and installation, and reduce the risks associated with...

  13. Double-strand break repair and genetic recombination in topoisomerase and primase mutants of bacteriophage T4.

    PubMed

    Shcherbakov, Victor P; Kudryashova, Elena

    2014-09-01

    The effects of primase and topoisomerase II deficiency on the double-strand break (DSB) repair and genetic recombination in bacteriophage T4 were studied in vivo using focused recombination. Site-specific DSBs were induced by SegC endonuclease in the rIIB gene of one of the parents. The frequency/distance relationship was determined in crosses of the wild-type phage, topoisomerase II mutant amN116 (gene 39), and primase mutant E219 (gene 61). Ordinary two-factor (i×j) and three-factor (i k×j) crosses between point rII mutations were also performed. These data provide information about the frequency and distance distribution of the single-exchange (splice) and double-exchange (patch) events. In two-factor crosses ets1×i, the topoisomerase and primase mutants had similar recombinant frequencies in crosses at ets1-i distances longer than 1000 bp, comprising about 80% of the corresponding wild-type values. They, however, differ remarkably in crosses at shorter distances. In the primase mutant, the recombinant frequencies are similar to those in the wild-type crosses at distances less than 100 bp, being a bit diminished at longer distances. In two-factor crosses ets1×i of the topoisomerase mutant, the recombinant frequencies were reduced ten-fold at the shortest distances. In three-factor crosses a6 ets1×i, where we measure patch-related recombination, the primase mutant was quite proficient across the entire range of distances. The topoisomerase mutant crosses demonstrated virtually complete absence of rII(+) recombinants at distances up to 33 bp, with the frequencies increasing steadily at longer distances. The data were interpreted as follows. The primase mutant is fully recombination-proficient. An obvious difference from the wild-type state is some shortage of EndoVII function leading to prolonged existence of HJs and thus stretched out ds-branch migration. This is also true for the topoisomerase mutant. However, the latter is deficient in the ss-branch migration step of the DSB repair pathway and partially deficient in HJ initiation. In apparent contradiction to their effects on the DSB-induced site-specific recombination, the topoisomerase and primase mutants demonstrated about 3-8-fold increase in the recombinant frequencies in the ordinary crosses, with the recombination running exclusively via patches. This implies that most of the spontaneous recombination events are not initiated by dsDNA ends in these mutants. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Field repair of coated columbium Thermal Protection System (TPS)

    NASA Technical Reports Server (NTRS)

    Culp, J. D.

    1972-01-01

    The requirements for field repair of coated columbian panels were studied, and the probable cause of damage were identified. The following types of repair methods were developed, and are ready for use on an operational system: replacement of fused slurrey silicide coating by a short processing cycle using a focused radiant spot heater; repair of the coating by a glassy matrix ceramic composition which is painted or sprayed over the defective area; and repair of the protective coating by plasma spraying molybdenum disilicide over the damaged area employing portable equipment.

  15. In vitro biomechanical and biocompatible evaluation of natural hydroxyapatite/chitosan composite for bone repair.

    PubMed

    Lü, Xiaoying; Zheng, Buzhong; Tang, Xiaojun; Zhao, Lifeng; Lu, Jieyan; Zhang, Zhiwei; Zhang, Jizhong; Cui, Wei

    2011-01-01

    To evaluate the biomechanical properties and biocompatibility of natural hydroxyapatite/chitosan (HA/CS) composites. The natural HA/CS composites with a different proportion of HA and CS were prepared by the cross-linking method, and then the compressive strength, microstructure and pH values of extracts from these composites were measured by SEM and pH meter, respectively. Subsequently, the biocompatibility of the composites was evaluated by means of a series of biological tests, including MTT, acute systemic toxicity, heat source, and hemolysis tests in vitro. The chitosan content in the composites had significantly influenced the mechanical properties and microstructure of the composites. The pH value of the composite extract was approximately 7.0, which was very close to that of human plasma. Furthermore, the natural HA/CS composites showed no cytotoxicity, irritation, teratogenicity, carcinogenicity and special pyrogen. These results indicated that the natural HA/CS composite may be a potential bone repair material.

  16. Human Fanconi Anemia Complementation Group A Protein Stimulates the 5’ Flap Endonuclease Activity of FEN1

    PubMed Central

    Qian, Liangyue; Yuan, Fenghua; Rodriguez-Tello, Paola; Padgaonkar, Suyog; Zhang, Yanbin

    2013-01-01

    In eukaryotic cells, Flap endonuclease 1 (FEN1) is a major structure-specific endonuclease that processes 5’ flapped structures during maturation of lagging strand DNA synthesis, long patch base excision repair, and rescue of stalled replication forks. Here we report that fanconi anemia complementation group A protein (FANCA), a protein that recognizes 5’ flap structures and is involved in DNA repair and maintenance of replication forks, constantly stimulates FEN1-mediated incision of both DNA and RNA flaps. Kinetic analyses indicate that FANCA stimulates FEN1 by increasing the turnover rate of FEN1 and altering its substrate affinity. More importantly, six pathogenic FANCA mutants are significantly less efficient than the wild-type at stimulating FEN1 endonuclease activity, implicating that regulation of FEN1 by FANCA contributes to the maintenance of genomic stability. PMID:24349332

  17. Engineering biosynthetic excitable tissues from unexcitable cells for electrophysiological and cell therapy studies.

    PubMed

    Kirkton, Robert D; Bursac, Nenad

    2011-01-01

    Patch-clamp recordings in single-cell expression systems have been traditionally used to study the function of ion channels. However, this experimental setting does not enable assessment of tissue-level function such as action potential (AP) conduction. Here we introduce a biosynthetic system that permits studies of both channel activity in single cells and electrical conduction in multicellular networks. We convert unexcitable somatic cells into an autonomous source of electrically excitable and conducting cells by stably expressing only three membrane channels. The specific roles that these expressed channels have on AP shape and conduction are revealed by different pharmacological and pacing protocols. Furthermore, we demonstrate that biosynthetic excitable cells and tissues can repair large conduction defects within primary 2- and 3-dimensional cardiac cell cultures. This approach enables novel studies of ion channel function in a reproducible tissue-level setting and may stimulate the development of new cell-based therapies for excitable tissue repair.

  18. An evaluation of Admedus' tissue engineering process-treated (ADAPT) bovine pericardium patch (CardioCel) for the repair of cardiac and vascular defects.

    PubMed

    Strange, Geoff; Brizard, Christian; Karl, Tom R; Neethling, Leon

    2015-03-01

    Tissue engineers have been seeking the 'Holy Grail' solution to calcification and cytotoxicity of implanted tissue for decades. Tissues with all of the desired qualities for surgical repair of congenital heart disease (CHD) are lacking. An anti-calcification tissue engineering process (ADAPT TEP) has been developed and applied to bovine pericardium (BP) tissue (CardioCel, AdmedusRegen Pty Ltd, Perth, WA, Australia) to eliminate cytotoxicity, improve resistance to acute and chronic inflammation, reduce calcification and facilitate controlled tissue remodeling. Clinical data in pediatric patients, and additional pre-market authorized prescriber data demonstrate that CardioCel performs extremely well in the short term and is safe and effective for a range of congenital heart deformations. These data are supported by animal studies which have shown no more than normal physiologic levels of calcification, with good durability, biocompatibility and controlled healing.

  19. Biomaterials in myocardial tissue engineering

    PubMed Central

    Reis, Lewis A.; Chiu, Loraine L. Y.; Feric, Nicole; Fu, Lara; Radisic, Milica

    2016-01-01

    Cardiovascular disease is the leading cause of death in the developed world, and as such there is a pressing need for treatment options. Cardiac tissue engineering emerged from the need to develop alternate sources and methods of replacing tissue damaged by cardiovascular diseases, as the ultimate treatment option for many who suffer from end-stage heart failure is a heart transplant. In this review we focus on biomaterial approaches to augment injured or impaired myocardium with specific emphasis on: the design criteria for these biomaterials; the types of scaffolds—composed of natural or synthetic biomaterials, or decellularized extracellular matrix—that have been used to develop cardiac patches and tissue models; methods to vascularize scaffolds and engineered tissue, and finally injectable biomaterials (hydrogels)designed for endogenous repair, exogenous repair or as bulking agents to maintain ventricular geometry post-infarct. The challenges facing the field and obstacles that must be overcome to develop truly clinically viable cardiac therapies are also discussed. PMID:25066525

  20. Buccal mucosa ureteroplasty for the treatment of complex ureteric injury.

    PubMed

    Sadhu, Sagar; Pandit, Kuntal; Roy, Manas K; Bajoria, Suresh K

    2011-01-01

    Bowel interposition and auto-transplantation of kidney, thought to be a major undertaking, remain the traditional option for the treatment of major and complex ureteric lesions. Buccal mucosa, a well known tissue for urethral reconstruction, can be used safely for the repair of ureter. However, this has been reported poorly in the literature. Here we report a 59- year-old female who had a major ureteric injury by Dormia basket during ureteroscopic extraction of a 2.6 cm impacted stone at pelvi- ureteric junction. On exploration, a long anterior slit was found in the upper ureter measuring approximately 8 cm. It was successfully repaired by free buccal mucosal patch graft over a Double J stent. Thus, a major surgery was avoided. Intra venous urography at 6-month follow up demonstrated a patent ureter. Our experience is encouraging and merits wider application in complex ureteric lesion.

  1. International Space Station (ISS)

    NASA Image and Video Library

    2005-06-09

    The STS-121 patch depicts the Space Shuttle docked with the International Space Station (ISS) in the foreground, overlaying the astronaut symbol with three gold columns and a gold star. The ISS is shown in the configuration that it was during the STS-121 mission. The background shows the nighttime Earth with a dawn breaking over the horizon. STS-121, ISS mission ULF1.1, was the final Shuttle Return to Flight test mission. This utilization and logistics flight delivered a multipurpose logistics module (MPLM) to the ISS with several thousand pounds of new supplies and experiments. In addition, some new orbital replacement units (ORUs) were delivered and stowed externally on the ISS on a special pallet. These ORUs are spares for critical machinery located on the outside of the ISS. During this mission the crew also carried out testing of Shuttle inspection and repair hardware, as well as evaluated operational techniques and concepts for conducting on-orbit inspection and repair.

  2. Finite-Element Modeling of a Damaged Pipeline Repaired Using the Wrap of a Composite Material

    NASA Astrophysics Data System (ADS)

    Lyapin, A. A.; Chebakov, M. I.; Dumitrescu, A.; Zecheru, G.

    2015-07-01

    The nonlinear static problem of FEM modeling of a damaged pipeline repaired by a composite material and subjected to internal pressure is considered. The calculation is carried out using plasticity theory for the pipeline material and considering the polymeric filler and the composite wrap. The level of stresses in various zones of the structure is analyzed. The most widespread alloy used for oil pipelines is selected as pipe material. The contribution of each component of the pipeline-filler-wrap system to the level of stresses is investigated. The effect of the number of composite wrap layers is estimated. The results obtained allow one to decrease the costs needed for producing test specimens.

  3. Autologous Cartilage Chip Transplantation Improves Repair Tissue Composition Compared With Marrow Stimulation.

    PubMed

    Christensen, Bjørn Borsøe; Olesen, Morten Lykke; Lind, Martin; Foldager, Casper Bindzus

    2017-06-01

    Repair of chondral injuries by use of cartilage chips has recently demonstrated clinical feasibility. To investigate in vivo cartilage repair outcome of autologous cartilage chips compared with marrow stimulation in full-thickness cartilage defects in a minipig model. Controlled laboratory study. Six Göttingen minipigs received two 6-mm chondral defects in the medial and lateral trochlea of each knee. The two treatment groups were (1) autologous cartilage chips embedded in fibrin glue (ACC) (n = 12) and (2) marrow stimulation (MST) (n = 12). The animals were euthanized after 6 months, and the composition of repair tissue was quantitatively determined using histomorphometry. Semiquantitative evaluation was performed by means of the International Cartilage Repair Society (ICRS) II score. Collagen type II staining was used to further evaluate the repair tissue composition. Significantly more hyaline cartilage was found in the ACC (17.1%) compared with MST (2.9%) group ( P < .01). Furthermore, the ACC group had significantly less fibrous tissue (23.8%) compared with the MST group (41.1%) ( P < .01). No significant difference in fibrocartilage content was found (54.7% for ACC vs 50.8% for MST). The ACC group had significantly higher ICRS II scores for tissue morphological characteristics, matrix staining, cell morphological characteristics, surface assessment, mid/deep assessment, and overall assessment ( P < .05). The ACC-treated defects had significantly more collagen type II staining (54.5%) compared with the MST-treated defects (28.1%) ( P < .05). ACC transplant resulted in improved quality of cartilage repair tissue compared with MST at 6 months postoperatively. Further studies are needed to investigate ACC as a possible alternative first-line treatment for focal cartilage injuries in the knee.

  4. Composite Repairs of Cracked Metallic Airframe Structures

    DTIC Science & Technology

    1993-05-01

    painting of the surface of composites. Therefore, repairs on external surfaces of aircraft should be painted prior to service. 30 2. ANALITICAL AND...tends to decrease the ’apparent’ stress intensity factor. These factors have to be taken into account when comparing the analytical predictions with the...analytical predictions . The fatigue crack growth data for one of the specimens appears in Figure 2-46Zhe ’Inferred’ stress-intensity factor [from the

  5. Microtensile Bond Strength of New Ceramic/Polymer Materials Repaired with Composite Resin

    DTIC Science & Technology

    2015-06-30

    also have been shown to have higher enamel wear rates than composite-resin CAD/CAM restorations (Mӧrmann et al, 2013). As material choices, cost, and...although the longevity of these repairs has not been validated by clinical studies. Paradigm MZ100 showed the least amount of opposing enamel wear...ability to absorb shock, resist staining and stop crack propagation. Further manufacturer claims are that ceramic/polymer materials are easily

  6. In-Space Repair of Reinforced Carbon-Carbon Thermal Protection System Structures

    NASA Technical Reports Server (NTRS)

    Singh, Mrityunjay

    2006-01-01

    Advanced repair and refurbishment technologies are critically needed for the thermal protection system of current space transportation system as well as for future Crew Exploration Vehicles (CEV). The damage to these components could be caused by impact during ground handling or due to falling of ice or other objects during launch. In addition, in-orbit damage includes micrometeoroid and orbital debris impact as well as different factors (weather, launch acoustics, shearing, etc.) during launch and re-entry. The GRC developed GRABER (Glenn Refractory Adhesive for Bonding and Exterior Repair) material has shown multiuse capability for repair of small cracks and damage in reinforced carbon-carbon (RCC) material. The concept consists of preparing an adhesive paste of desired ceramic with appropriate additives and then applying the paste to the damaged/cracked area of the RCC composites with adhesive delivery system. The adhesive paste cures at 100-120 C and transforms into a high temperature ceramic during simulated entry conditions. A number of plasma torch and ArcJet tests were carried out to evaluate the crack repair capability of GRABER materials for Reinforced Carbon-Carbon (RCC) composites. For the large area repair applications, integrated system for tile and leading edge repair (InSTALER) have been developed. In this presentation, critical in-space repair needs and technical challenges as well as various issues and complexities will be discussed along with the plasma performance and post test characterization of repaired RCC materials.

  7. In-Space Repair and Refurbishment of Thermal Protection System Structures for Reusable Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Singh, M.

    2007-01-01

    Advanced repair and refurbishment technologies are critically needed for the thermal protection system of current space transportation systems as well as for future launch and crew return vehicles. There is a history of damage to these systems from impact during ground handling or ice during launch. In addition, there exists the potential for in-orbit damage from micrometeoroid and orbital debris impact as well as different factors (weather, launch acoustics, shearing, etc.) during launch and re-entry. The GRC developed GRABER (Glenn Refractory Adhesive for Bonding and Exterior Repair) material has shown multiuse capability for repair of small cracks and damage in reinforced carbon-carbon (RCC) material. The concept consists of preparing an adhesive paste of desired ceramic with appropriate additives and then applying the paste to the damaged/cracked area of the RCC composites with an adhesive delivery system. The adhesive paste cures at 100-120 C and transforms into a high temperature ceramic during reentry conditions. A number of plasma torch and ArcJet tests were carried out to evaluate the crack repair capability of GRABER materials for Reinforced Carbon-Carbon (RCC) composites. For the large area repair applications, Integrated Systems for Tile and Leading Edge Repair (InSTALER) have been developed and evaluated under various ArcJet testing conditions. In this presentation, performance of the repair materials as applied to RCC is discussed. Additionally, critical in-space repair needs and technical challenges are reviewed.

  8. State of the Art: MR Imaging after Knee Cartilage Repair Surgery.

    PubMed

    Guermazi, Ali; Roemer, Frank W; Alizai, Hamza; Winalski, Carl S; Welsch, Goetz; Brittberg, Mats; Trattnig, Siegfried

    2015-10-01

    Cartilage injuries are common, especially in athletes. Because these injuries frequently affect young patients, and they have the potential to progress to osteoarthritis, treatment to alleviate symptoms and delay joint degeneration is warranted. A number of surgical techniques are available to treat focal chondral defects, including marrow stimulation, osteochondral auto- and allografting, and autologous chondrocyte implantation. Although arthroscopy is considered the standard of reference for the evaluation of cartilage before and after repair, it is invasive with associated morbidity and cannot adequately depict the deep cartilage layer and underlying bone. Magnetic resonance (MR) imaging provides unparalleled noninvasive assessment of the repair site and all other joint tissues. MR observation of cartilage repair tissue is a well-established semiquantitative scoring system for repair tissue that has primarily been used in clinical research studies. The cartilage repair osteoarthritis knee score (CROAKS) optimizes comprehensive morphologic assessment of the knee joint after cartilage repair. Furthermore, quantitative, compositional MR imaging measurements (eg, T2, T2*, T1ρ), delayed gadolinium-enhanced MR imaging of cartilage (dGEMRIC), and sodium imaging are available for biochemical assessment. These quantitative MR imaging techniques help assess collagen content and orientation, water content, and glycosaminoglycan and/or proteoglycan content both in the repair tissue as it matures and in the "native" cartilage. In this review, the authors discuss the principles of state-of-the-art morphologic and compositional MR imaging techniques for imaging of cartilage repair and their application to longitudinal studies. (©) RSNA, 2015.

  9. [Nano-hydroxyapatite/collagen composite for bone repair].

    PubMed

    Feng, Qing-ling; Cui, Fu-zhai; Zhang, Wei

    2002-04-01

    To develop nano-hydroxyapatite/collagen (NHAC) composite and test its ability in bone repairing. NHAC composite was developed by biomimetic method. The composite showed some features of natural bone in both composition and microstructure. The minerals could contribute to 50% by weight of the composites in sheet form. The inorganic phase in the composite was carbonate-substituted hydroxyapatite (HA) with low crystallinity and nanometer size. HA precipitates were uniformly distributed on the type I collagen matrix without preferential orientation. The composite exhibited an isotropic mechanical behavior. However, the resistance of the composite to localized pressure could reach the lower limit of that of femur compacta. The tissue response to the NHAC composite implanted in marrow cavity was investigated. Knoop micro-hardness test was performed to compare the mechanical behavior of the composite and bone. At the interface of the implant and marrow tissue, solution-mediated dissolution and macrophage-mediated resorption led to the degradation of the composite, followed by interfacial bone formation by osteoblasts. The process of implant degradation and bone substitution was reminiscent of bone remodeling. The composite can be incorporated into bone metabolism instead of being a permanent implant.

  10. Object-based class modelling for multi-scale riparian forest habitat mapping

    NASA Astrophysics Data System (ADS)

    Strasser, Thomas; Lang, Stefan

    2015-05-01

    Object-based class modelling allows for mapping complex, hierarchical habitat systems. The riparian zone, including forests, represents such a complex ecosystem. Forests within riparian zones are biologically high productive and characterized by a rich biodiversity; thus considered of high community interest with an imperative to be protected and regularly monitored. Satellite earth observation (EO) provides tools for capturing the current state of forest habitats such as forest composition including intermixture of non-native tree species. Here we present a semi-automated object based image analysis (OBIA) approach for the mapping of riparian forests by applying class modelling of habitats based on the European Nature Information System (EUNIS) habitat classifications and the European Habitats Directive (HabDir) Annex 1. A very high resolution (VHR) WorldView-2 satellite image provided the required spatial and spectral details for a multi-scale image segmentation and rule-base composition to generate a six-level hierarchical representation of riparian forest habitats. Thereby habitats were hierarchically represented within an image object hierarchy as forest stands, stands of homogenous tree species and single trees represented by sunlit tree crowns. 522 EUNIS level 3 (EUNIS-3) habitat patches with a mean patch size (MPS) of 12,349.64 m2 were modelled from 938 forest stand patches (MPS = 6868.20 m2) and 43,742 tree stand patches (MPS = 140.79 m2). The delineation quality of the modelled EUNIS-3 habitats (focal level) was quantitatively assessed to an expert-based visual interpretation showing a mean deviation of 11.71%.

  11. Safety and efficacy of personal care products containing colloidal oatmeal.

    PubMed

    Criquet, Maryline; Roure, Romain; Dayan, Liliane; Nollent, Virginie; Bertin, Christiane

    2012-01-01

    Colloidal oatmeal is a natural ingredient used in the formulation of a range of personal care products for relief of skin dryness and itchiness. It is also used as an adjunctive product in atopic dermatitis. The safety of personal care products used on vulnerable skin is of particular importance and the risk of developing further skin irritations and/or allergies should be minimized. In a series of studies, we tested the safety of personal care products containing oatmeal (creams, cleansers, lotions) by assessing their irritant/allergenic potential on repeat insult patch testing, in safety-in-use and ocular studies using subjects with nonsensitive and sensitive skin. We also tested the skin moisturizing and repair properties of an oatmeal-containing skin care product for dry skin. We found that oatmeal-containing personal care products had very low irritant potential as well as a very low allergenic sensitization potential. Low-level reactions were documented in 1.0% of subjects during the induction phase of repeat insult patch testing; one of 2291 subjects developed a persistent but doubtful low-level reaction involving edema during the challenge phase in repeat insult patch testing. No allergies were reported by 80 subjects after patch testing after in-use application. Sustained skin moisturizing was documented in subjects with dry skin that lasted up to 2 weeks after product discontinuation. Our results demonstrate that colloidal oatmeal is a safe and effective ingredient in personal care products. No allergies were reported by consumers of 445,820 products sold during a 3-year period.

  12. Safety and efficacy of personal care products containing colloidal oatmeal

    PubMed Central

    Criquet, Maryline; Roure, Romain; Dayan, Liliane; Nollent, Virginie; Bertin, Christiane

    2012-01-01

    Background Colloidal oatmeal is a natural ingredient used in the formulation of a range of personal care products for relief of skin dryness and itchiness. It is also used as an adjunctive product in atopic dermatitis. The safety of personal care products used on vulnerable skin is of particular importance and the risk of developing further skin irritations and/or allergies should be minimized. Methods In a series of studies, we tested the safety of personal care products containing oatmeal (creams, cleansers, lotions) by assessing their irritant/allergenic potential on repeat insult patch testing, in safety-in-use and ocular studies using subjects with nonsensitive and sensitive skin. We also tested the skin moisturizing and repair properties of an oatmeal-containing skin care product for dry skin. Results We found that oatmeal-containing personal care products had very low irritant potential as well as a very low allergenic sensitization potential. Low-level reactions were documented in 1.0% of subjects during the induction phase of repeat insult patch testing; one of 2291 subjects developed a persistent but doubtful low-level reaction involving edema during the challenge phase in repeat insult patch testing. No allergies were reported by 80 subjects after patch testing after in-use application. Sustained skin moisturizing was documented in subjects with dry skin that lasted up to 2 weeks after product discontinuation. Conclusion Our results demonstrate that colloidal oatmeal is a safe and effective ingredient in personal care products. No allergies were reported by consumers of 445,820 products sold during a 3-year period. PMID:23204849

  13. A novel basalt fiber-reinforced polylactic acid composite for hard tissue repair.

    PubMed

    Chen, Xi; Li, Yan; Gu, Ning

    2010-08-01

    A basalt fiber (BF) was, for the first time, introduced into a poly(l-lactic acid) (PLLA) matrix as innovative reinforcement to fabricate composite materials for hard tissue repair. Firstly, BF/PLLA composites and pure PLLA were produced by the methods of solution blending and freeze drying. The results showed that basalt fibers can be uniformly dispersed in the PLLA matrix and significantly improve the mechanical properties and hydrophilicity of the PLLA matrix. The presence of basalt fibers may retard the polymer degradation rate and neutralize the acid degradation from PLLA. Osteoblasts were cultured in vitro to evaluate the cytocompatibility of the composite. An MTT assay revealed that osteoblasts proliferated well for 7 days and there was little difference found in their viability on both PLLA and BF/PLLA films, which was consistent with the alkaline phosphatase (ALP) activity results. A fluorescent staining observation showed that osteoblasts grew well on the composites. SEM images displayed that osteoblasts tended to grow along the fiber axis. The formation of mineralized nodules was observed on the films by Alizarin red S staining. These results suggest that the presence of basalt fibers does not noticeably affect osteoblastic behavior and the designed composites are osteoblast compatible. It is concluded that basalt fibers, as reinforcing fibers, may have promising applications in hard tissue repair.

  14. Damage tolerance certification of a fighter horizontal stabilizer

    NASA Astrophysics Data System (ADS)

    Huang, Jia-Yen; Tsai, Ming-Yang; Chen, Jong-Sheng; Ong, Ching-Long

    1995-05-01

    A review of the program for the damage tolerance certification test of a composite horizontal stabilizer (HS) of a fighter is presented. The object of this program is to certify that the fatigue life and damage tolerance strength of a damaged composite horizontal stabilizer meets the design requirements. According to the specification for damage tolerance certification, a test article should be subjected to two design lifetimes of flight-by-flight load spectra simulating the in-service fatigue loading condition for the aircraft. However, considering the effect of environmental change on the composite structure, one additional lifetime test was performed. In addition, to evaluate the possibilities for extending the service life of the structure, one more lifetime test was carried out with the spectrum increased by a factor of 1.4. To assess the feasibility and reliability of repair technology on a composite structure, two damaged areas were repaired after two lifetimes of damage tolerance test. On completion of four lifetimes of the damage tolerance test, the static residual strength was measured to check whether structural strength after repair met the requirements. Stiffness and static strength of the composite HS with and without damage were evaluated and compared.

  15. Composite Structure Repair. Addendum

    DTIC Science & Technology

    1984-08-01

    room temperature curing systems . For permanent repairs no reduction in " serciveability with regard to the maximum design temperature and the design...pressure for ply compaction and conformation of bonding surfaces. In certain instances, ambient temperature cure systems may be sufficient. - Noisture...than those placed on radomes. Some of ,the resins used for the repairs were ambient curing systems which also required no additional pressure for

  16. Quantifying forest vertical structure to determine bird habitat quality in the Greenbelt Corridor, Denton, TX

    NASA Astrophysics Data System (ADS)

    Matsubayashi, Shiho

    This study presents the integration of light detection and range (LiDAR) and hyperspectral remote sensing to create a three-dimensional bird habitat map in the Greenbelt Corridor of the Elm Fork of the Trinity River. This map permits to examine the relationship between forest stand structure, landscape heterogeneity, and bird community composition. A biannual bird census was conducted at this site during the breeding seasons of 2009 and 2010. Census data combined with the three-dimensional map suggest that local breeding bird abundance, community structure, and spatial distribution patterns are highly influenced by vertical heterogeneity of vegetation surface. For local breeding birds, vertical heterogeneity of canopy surface within stands, connectivity to adjacent forest patches, largest forest patch index, and habitat (vegetation) types proved to be the most influential factors to determine bird community assemblages. Results also highlight the critical role of secondary forests to increase functional connectivity of forest patches. Overall, three-dimensional habitat descriptions derived from integrated LiDAR and hyperspectral data serve as a powerful bird conservation tool that shows how the distribution of bird species relates to forest composition and structure at various scales.

  17. Technical Assessment of the National Full Scale Aerodynamic Complex Fan Blades Repair

    NASA Technical Reports Server (NTRS)

    Young, Clarence P., Jr.; Dixon, Peter G.; St.Clair, Terry L.; Johns, William E.

    1998-01-01

    This report describes the principal activities of a technical review team formed to address National Full Scale Aerodynamic Complex (NFAC) blade repair problems. In particular, the problem of lack of good adhesive bonding of the composite overwrap to the Hyduliginum wood blade material was studied extensively. Description of action plans and technical elements of the plans are provided. Results of experiments designed to optimize the bonding process and bonding strengths obtained on a full scale blade using a two-step cure process with adhesive primers are presented. Consensus recommendations developed by the review team in conjunction with the NASA Ames Fan Blade Repair Project Team are provided along with lessons learned on this program. Implementation of recommendations resulted in achieving good adhesive bonds between the composite materials and wooden blades, thereby providing assurance that the repaired fan blades will meet or exceed operational life requirements.

  18. Effect of different adhesion strategies on bond strength of resin composite to composite-dentin complex.

    PubMed

    Özcan, M; Pekkan, G

    2013-01-01

    Service life of discolored and abraded resin composite restorations could be prolonged by repair or relayering actions. Composite-composite adhesion can be achieved successfully using some surface conditioning methods, but the most effective adhesion protocol for relayering is not known when the composite restorations are surrounded with dentin. This study evaluated the effect of three adhesion strategies on the bond strength of resin composite to the composite-dentin complex. Intact maxillary central incisors (N=72, n=8 per subgroup) were collected and the coronal parts of the teeth were embedded in autopolymerized poly(methyl tfr54methacrylate) surrounded by a polyvinyl chloride cylinder. Cylindrical cavities (diameter: 2.6 mm; depth: 2 mm) were opened in the middle of the labial surfaces of the teeth using a standard diamond bur, and the specimens were randomly divided into three groups. Two types of resin composite, namely microhybrid (Quadrant Anterior Shine; AS) and nanohybrid (Grandio; G), were photo-polymerized incrementally in the cavities according to each manufacturer's recommendations. The composite-enamel surfaces were ground finished to 1200-grit silicone carbide paper until the dentin was exposed. The surfaces of the substrate composites and the surrounding dentin were conditioned according to one of the following adhesion protocols: protocol 1: acid-etching (dentin) + silica coating (composite) + silanization (composite) + primer (dentin) + bonding agent (dentin + composite); protocol 2: silica coating (composite) + acid-etching (dentin) + silanization (composite) + primer (dentin) + bonding agent (dentin + composite); and protocol 3: acid-etching (dentin) + primer (dentin) + silanization (composite) + bonding agent (dentin + composite). Applied primer and bonding agents were the corresponding materials of the composite manufacturer. Silica coating (CoJet sand, 30 μm) was achieved using a chairside air-abrasion device (distance: 10 mm; duration: four seconds in circular motion). After conditioning protocols, the repair resin was adhered to the substrate surfaces using transparent polyethylene molds (diameter: 3.6 mm) incrementally and photo-polymerized. The substrate-adherend combinations were as follows: AS-AS, G-G, AS-G. Shear force was applied to the adhesive interface in a Universal Testing Machine (crosshead speed: 1 mm/min). The types of failures were further evaluated and categorized as follows: 1) cohesive in the composite substrate and 2) adhesive at the interface. Bond strength values (MPa) were statistically analyzed using two-way analysis of variance and least significant difference post hoc tests (α=0.05). Significant effects of the adhesion strategy (p=0.006) and the composite type (p=0.000) were found. Interaction terms were not significant (p=0.292). Regardless of the substrate-adherend combination, protocol 1 (17-22 MPa) showed significantly higher results than did protocols 2 (15-17 MPa) and 3 (11-17 MPa) (p=0.028, p=0.002, respectively). The highest results were obtained from the G-G combination after all three protocols (17-22 MPa). The incidence of cohesive failures was more common when the substrate and the adherend were the same composite type (AS-AS: 87.5%, 87.5%, 75%; G-G: 100%, 75%, 50% for protocols 1, 2, and 3, respectively). When substrate and adherend were used interchangeably, adhesive failures were more frequent (25%, 50%, and 100% for protocol 1, 2, and 3, respectively). When the substrate and the adherend are of the same type, greater repair strength could be expected. In the repair of composites next to the dentin, depending on the composite type, conditioning the composite with silica coating and silanization after etching the dentin adds to the repair strength compared to the results obtained with silane application only.

  19. A novel approach for the fine tuning of resonance frequency of patch antenna

    NASA Astrophysics Data System (ADS)

    Mathur, Monika; Singh, Ghanshyam; Bhatnagar, S. K.

    2013-01-01

    When a patch antenna is fabricated, dimensions of the patch may be slightly different from the designed values due to tolerances in the fabrication process. This alters the resonance frequency of the antenna. To overcome this problem this paper presents a new design approach for fine tuning the resonance frequency by dielectric constant engineering. This approach is especially suited to low temperature co-fired ceramic (LTCC) and similar processes where the antenna dielectric is composed of several layers. Composite dielectric constant of this multilayer structure is altered in such a way that the resonant frequency is set back to the designed value. It has been verified that for proposed micro strip antenna (MSA) design, the frequency-area curve follows a quadratic relation with a variable R (Ratio of cavity area to the patch area). This mathematical model is true up to R 1.27. After this saturation effects set in and the curve follows a straight line behavior.≡

  20. Design and fabrication of a microstrip patch antenna with a low radar cross section in the X-band

    NASA Astrophysics Data System (ADS)

    Jang, Hong-Kyu; Lee, Won-Jun; Kim, Chun-Gon

    2011-01-01

    In this study, the authors developed a radar absorbing method to reduce the antenna radar cross section (RCS) without any loss of antenna performance. The new method was based upon an electromagnetic bandgap (EBG) absorber using conducting polymer (CP). First, a microstrip patch antenna was made by using a copper film and glass/epoxy composite materials, which are typically used for load-bearing structures, such as aircraft and other vehicles. Then, CP EBG patterns were also designed that had a 90% electromagnetic (EM) wave absorbing performance within the X-band (8.2-12.4 GHz). Finally, the CP EBG patterns were printed on the top surface of the microstrip patch antenna. The measured radar absorbing performance of the fabricated patch antenna showed that the frontal RCS of the antenna declined by nearly 95% at 10 GHz frequency while the CP EBG patterns had almost no effect on the antenna's performance.

Top