Sample records for composite reliability evaluation

  1. Probability techniques for reliability analysis of composite materials

    NASA Technical Reports Server (NTRS)

    Wetherhold, Robert C.; Ucci, Anthony M.

    1994-01-01

    Traditional design approaches for composite materials have employed deterministic criteria for failure analysis. New approaches are required to predict the reliability of composite structures since strengths and stresses may be random variables. This report will examine and compare methods used to evaluate the reliability of composite laminae. The two types of methods that will be evaluated are fast probability integration (FPI) methods and Monte Carlo methods. In these methods, reliability is formulated as the probability that an explicit function of random variables is less than a given constant. Using failure criteria developed for composite materials, a function of design variables can be generated which defines a 'failure surface' in probability space. A number of methods are available to evaluate the integration over the probability space bounded by this surface; this integration delivers the required reliability. The methods which will be evaluated are: the first order, second moment FPI methods; second order, second moment FPI methods; the simple Monte Carlo; and an advanced Monte Carlo technique which utilizes importance sampling. The methods are compared for accuracy, efficiency, and for the conservativism of the reliability estimation. The methodology involved in determining the sensitivity of the reliability estimate to the design variables (strength distributions) and importance factors is also presented.

  2. Computer-aided design of polymers and composites

    NASA Technical Reports Server (NTRS)

    Kaelble, D. H.

    1985-01-01

    This book on computer-aided design of polymers and composites introduces and discusses the subject from the viewpoint of atomic and molecular models. Thus, the origins of stiffness, strength, extensibility, and fracture toughness in composite materials can be analyzed directly in terms of chemical composition and molecular structure. Aspects of polymer composite reliability are considered along with characterization techniques for composite reliability, relations between atomic and molecular properties, computer aided design and manufacture, polymer CAD/CAM models, and composite CAD/CAM models. Attention is given to multiphase structural adhesives, fibrous composite reliability, metal joint reliability, polymer physical states and transitions, chemical quality assurance, processability testing, cure monitoring and management, nondestructive evaluation (NDE), surface NDE, elementary properties, ionic-covalent bonding, molecular analysis, acid-base interactions, the manufacturing science, and peel mechanics.

  3. Behavioral Scale Reliability and Measurement Invariance Evaluation Using Latent Variable Modeling

    ERIC Educational Resources Information Center

    Raykov, Tenko

    2004-01-01

    A latent variable modeling approach to reliability and measurement invariance evaluation for multiple-component measuring instruments is outlined. An initial discussion deals with the limitations of coefficient alpha, a frequently used index of composite reliability. A widely and readily applicable structural modeling framework is next described…

  4. Reliability analysis of laminated CMC components through shell subelement techniques

    NASA Technical Reports Server (NTRS)

    Starlinger, Alois; Duffy, Stephen F.; Gyekenyesi, John P.

    1992-01-01

    An updated version of the integrated design program Composite Ceramics Analysis and Reliability Evaluation of Structures (C/CARES) was developed for the reliability evaluation of ceramic matrix composites (CMC) laminated shell components. The algorithm is now split into two modules: a finite-element data interface program and a reliability evaluation algorithm. More flexibility is achieved, allowing for easy implementation with various finite-element programs. The interface program creates a neutral data base which is then read by the reliability module. This neutral data base concept allows easy data transfer between different computer systems. The new interface program from the finite-element code Matrix Automated Reduction and Coupling (MARC) also includes the option of using hybrid laminates (a combination of plies of different materials or different layups) and allows for variations in temperature fields throughout the component. In the current version of C/CARES, a subelement technique was implemented, enabling stress gradients within an element to be taken into account. The noninteractive reliability function is now evaluated at each Gaussian integration point instead of using averaging techniques. As a result of the increased number of stress evaluation points, considerable improvements in the accuracy of reliability analyses were realized.

  5. Writing Evaluation: Rater and Task Effects on the Reliability of Writing Scores for Children in Grades 3 and 4

    PubMed Central

    Kim, Grace Young-Suk; Schatschneider, Christopher; Wanzek, Jeanne; Gatlin, Brandy; Al Otaiba, Stephanie

    2017-01-01

    We examined how raters and tasks influence measurement error in writing evaluation and how many raters and tasks are needed to reach a desirable level of .90 and .80 reliabilities for children in Grades 3 and 4. A total of 211 children (102 boys) were administered three tasks in narrative and expository genres, respectively, and their written compositions were evaluated in widely used evaluation methods for developing writers: holistic scoring, productivity, and curriculum-based writing scores. Results showed that 54% and 52% of variance in narrative and expository compositions were attributable to true individual differences in writing. Students’ scores varied largely by tasks (30.44% and 28.61% of variance), but not by raters. To reach the reliability of .90, multiple tasks and raters were needed, and for the reliability of .80, a single rater and multiple tasks were needed. These findings offer important implications about reliably evaluating children’s writing skills, given that writing is typically evaluated by a single task and a single rater in classrooms and even in state accountability systems. PMID:29075050

  6. Evaluation of composite adhesive bonds using digital image correlation

    NASA Astrophysics Data System (ADS)

    Shrestha, Shashi Shekhar

    Advanced composite materials are widely used for many structural applications in the aerospace/aircraft industries today. Joining of composite structures using adhesive bonding offers several advantages over traditional fastening methods. However, this technique is not yet employed for fastening the primary structures of aircrafts or space vehicles. There are several reasons for this: There are not any reliable non-destructive evaluation (NDE) methods that can quantify the strength of the bonds, and there are no certifications of quality assurance for inspecting the bond quality. Therefore, there is a significant need for an effective, reliable, easy to use NDE method for the analysis of composite adhesive joints. This research aimed to investigate an adhesively bonded composite-aluminum joints of variable bond strength using digital image correlation (DIC). There are many future possibilities in continuing this research work. As the application of composite materials and adhesive bond are increasing rapidly, the reliability of the composite structures using adhesive bond should quantified. Hence a lot of similar research using various adhesive bonds and materials can be conducted for characterizing the behavior of adhesive bond. The results obtained from this research will set the foundation for the development of ultrasonic DIC as a nondestructive approach for the evaluation of adhesive bond line.

  7. Evaluation of air-displacement plethysmography for body composition assessment in preterm infants

    USDA-ARS?s Scientific Manuscript database

    Adiposity may contribute to the future risk of disease. The aim of this study was to evaluate the accuracy and reliability of an air-displacement plethysmography (ADP) system to estimate percentage fat mass (%FM) in preterm infants and to evaluate interdevice reliability in infants. A total of 70 pr...

  8. Reliability analysis of laminated CMC components through shell subelement techniques

    NASA Technical Reports Server (NTRS)

    Starlinger, A.; Duffy, S. F.; Gyekenyesi, J. P.

    1992-01-01

    An updated version of the integrated design program C/CARES (composite ceramic analysis and reliability evaluation of structures) was developed for the reliability evaluation of CMC laminated shell components. The algorithm is now split in two modules: a finite-element data interface program and a reliability evaluation algorithm. More flexibility is achieved, allowing for easy implementation with various finite-element programs. The new interface program from the finite-element code MARC also includes the option of using hybrid laminates and allows for variations in temperature fields throughout the component.

  9. Reliability analysis of composite structures

    NASA Technical Reports Server (NTRS)

    Kan, Han-Pin

    1992-01-01

    A probabilistic static stress analysis methodology has been developed to estimate the reliability of a composite structure. Closed form stress analysis methods are the primary analytical tools used in this methodology. These structural mechanics methods are used to identify independent variables whose variations significantly affect the performance of the structure. Once these variables are identified, scatter in their values is evaluated and statistically characterized. The scatter in applied loads and the structural parameters are then fitted to appropriate probabilistic distribution functions. Numerical integration techniques are applied to compute the structural reliability. The predicted reliability accounts for scatter due to variability in material strength, applied load, fabrication and assembly processes. The influence of structural geometry and mode of failure are also considerations in the evaluation. Example problems are given to illustrate various levels of analytical complexity.

  10. Training less-experienced faculty improves reliability of skills assessment in cardiac surgery.

    PubMed

    Lou, Xiaoying; Lee, Richard; Feins, Richard H; Enter, Daniel; Hicks, George L; Verrier, Edward D; Fann, James I

    2014-12-01

    Previous work has demonstrated high inter-rater reliability in the objective assessment of simulated anastomoses among experienced educators. We evaluated the inter-rater reliability of less-experienced educators and the impact of focused training with a video-embedded coronary anastomosis assessment tool. Nine less-experienced cardiothoracic surgery faculty members from different institutions evaluated 2 videos of simulated coronary anastomoses (1 by a medical student and 1 by a resident) at the Thoracic Surgery Directors Association Boot Camp. They then underwent a 30-minute training session using an assessment tool with embedded videos to anchor rating scores for 10 components of coronary artery anastomosis. Afterward, they evaluated 2 videos of a different student and resident performing the task. Components were scored on a 1 to 5 Likert scale, yielding an average composite score. Inter-rater reliabilities of component and composite scores were assessed using intraclass correlation coefficients (ICCs) and overall pass/fail ratings with kappa. All components of the assessment tool exhibited improvement in reliability, with 4 (bite, needle holder use, needle angles, and hand mechanics) improving the most from poor (ICC range, 0.09-0.48) to strong (ICC range, 0.80-0.90) agreement. After training, inter-rater reliabilities for composite scores improved from moderate (ICC, 0.76) to strong (ICC, 0.90) agreement, and for overall pass/fail ratings, from poor (kappa = 0.20) to moderate (kappa = 0.78) agreement. Focused, video-based anchor training facilitates greater inter-rater reliability in the objective assessment of simulated coronary anastomoses. Among raters with less teaching experience, such training may be needed before objective evaluation of technical skills. Published by Elsevier Inc.

  11. Probabilistic sizing of laminates with uncertainties

    NASA Technical Reports Server (NTRS)

    Shah, A. R.; Liaw, D. G.; Chamis, C. C.

    1993-01-01

    A reliability based design methodology for laminate sizing and configuration for a special case of composite structures is described. The methodology combines probabilistic composite mechanics with probabilistic structural analysis. The uncertainties of constituent materials (fiber and matrix) to predict macroscopic behavior are simulated using probabilistic theory. Uncertainties in the degradation of composite material properties are included in this design methodology. A multi-factor interaction equation is used to evaluate load and environment dependent degradation of the composite material properties at the micromechanics level. The methodology is integrated into a computer code IPACS (Integrated Probabilistic Assessment of Composite Structures). Versatility of this design approach is demonstrated by performing a multi-level probabilistic analysis to size the laminates for design structural reliability of random type structures. The results show that laminate configurations can be selected to improve the structural reliability from three failures in 1000, to no failures in one million. Results also show that the laminates with the highest reliability are the least sensitive to the loading conditions.

  12. Evaluation of Validity and Reliability for Hierarchical Scales Using Latent Variable Modeling

    ERIC Educational Resources Information Center

    Raykov, Tenko; Marcoulides, George A.

    2012-01-01

    A latent variable modeling method is outlined, which accomplishes estimation of criterion validity and reliability for a multicomponent measuring instrument with hierarchical structure. The approach provides point and interval estimates for the scale criterion validity and reliability coefficients, and can also be used for testing composite or…

  13. Composite power system well-being analysis

    NASA Astrophysics Data System (ADS)

    Aboreshaid, Saleh Abdulrahman Saleh

    The evaluation of composite system reliability is extremely complex as it is necessary to include detailed modeling of both generation and transmission facilities and their auxiliary elements. The most significant quantitative indices in composite power system adequacy evaluation are those which relate to load curtailment. Many utilities have difficulty in interpreting the expected load curtailment indices as the existing models are based on adequacy analysis and in many cases do not consider realistic operating conditions in the system under study. This thesis presents a security based approach which alleviates this difficulty and provides the ability to evaluate the well-being of customer load points and the overall composite generation and transmission power system. Acceptable deterministic criteria are included in the probabilistic evaluation of the composite system reliability indices to monitor load point well-being. The degree of load point well-being is quantified in terms of the healthy and marginal state indices in addition to the traditional risk indices. The individual well-being indices of the different system load points are aggregated to produce system indices. This thesis presents new models and techniques to quantify the well-being of composite generation and, direct and alternating current transmission systems. Security constraints are basically the operating limits which must be satisfied for normal system operation. These constraints depend mainly on the purpose behind the study. The constraints which govern the practical operation of a power system are divided, in this thesis, into three sets namely, steady-state, voltage stability and transient stability constraints. The inclusion of an appropriate transient stability constraint will lead to a more accurate appraisal of the overall power system well-being. This thesis illustrates the utilization of a bisection method in the analytical evaluation of the critical clearing time which forms the basis of most existing stability assessments. The effect of employing high-speed-simultaneous or adaptive reclosing schemes is presented in this thesis. An effective and fast technique to incorporate voltage stability considerations in composite generation and transmission system reliability evaluation is also presented. The proposed technique can be easily incorporated in an existing composite power system reliability program using voltage stability constraints that are constructed for individual load points based on a relatively simple risk index. It is believed that the concepts, procedures and indices presented in this thesis will provide useful tools for power system designers, planners and operators and assist them to perform composite system well-being analysis in addition to traditional risk assessment.

  14. Optimizing the Reliability and Performance of Service Composition Applications with Fault Tolerance in Wireless Sensor Networks

    PubMed Central

    Wu, Zhao; Xiong, Naixue; Huang, Yannong; Xu, Degang; Hu, Chunyang

    2015-01-01

    The services composition technology provides flexible methods for building service composition applications (SCAs) in wireless sensor networks (WSNs). The high reliability and high performance of SCAs help services composition technology promote the practical application of WSNs. The optimization methods for reliability and performance used for traditional software systems are mostly based on the instantiations of software components, which are inapplicable and inefficient in the ever-changing SCAs in WSNs. In this paper, we consider the SCAs with fault tolerance in WSNs. Based on a Universal Generating Function (UGF) we propose a reliability and performance model of SCAs in WSNs, which generalizes a redundancy optimization problem to a multi-state system. Based on this model, an efficient optimization algorithm for reliability and performance of SCAs in WSNs is developed based on a Genetic Algorithm (GA) to find the optimal structure of SCAs with fault-tolerance in WSNs. In order to examine the feasibility of our algorithm, we have evaluated the performance. Furthermore, the interrelationships between the reliability, performance and cost are investigated. In addition, a distinct approach to determine the most suitable parameters in the suggested algorithm is proposed. PMID:26561818

  15. Probabilistic Methods for Structural Reliability and Risk

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.

    2010-01-01

    A probabilistic method is used to evaluate the structural reliability and risk of select metallic and composite structures. The method is a multiscale, multifunctional and it is based on the most elemental level. A multifactor interaction model is used to describe the material properties which are subsequently evaluated probabilistically. The metallic structure is a two rotor aircraft engine, while the composite structures consist of laminated plies (multiscale) and the properties of each ply are the multifunctional representation. The structural component is modeled by finite element. The solution method for structural responses is obtained by an updated simulation scheme. The results show that the risk for the two rotor engine is about 0.0001 and the composite built-up structure is also 0.0001.

  16. Probabilistic Methods for Structural Reliability and Risk

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.

    2008-01-01

    A probabilistic method is used to evaluate the structural reliability and risk of select metallic and composite structures. The method is a multiscale, multifunctional and it is based on the most elemental level. A multi-factor interaction model is used to describe the material properties which are subsequently evaluated probabilistically. The metallic structure is a two rotor aircraft engine, while the composite structures consist of laminated plies (multiscale) and the properties of each ply are the multifunctional representation. The structural component is modeled by finite element. The solution method for structural responses is obtained by an updated simulation scheme. The results show that the risk for the two rotor engine is about 0.0001 and the composite built-up structure is also 0.0001.

  17. Approaches for Combining Multiple Measures of Teacher Performance: Reliability, Validity, and Implications for Evaluation Policy

    ERIC Educational Resources Information Center

    Martínez, José Felipe; Schweig, Jonathan; Goldschmidt, Pete

    2016-01-01

    A key question facing teacher evaluation systems is how to combine multiple measures of complex constructs into composite indicators of performance. We use data from the Measures of Effective Teaching (MET) study to investigate the measurement properties of composite indicators obtained under various conjunctive, disjunctive (or complementary),…

  18. Composite shade guides and color matching.

    PubMed

    Paolone, Gaetano; Orsini, Giovanna; Manauta, Jordi; Devoto, Walter; Putignano, Angelo

    2014-01-01

    Finding reliable systems that can help the clinician match the color of direct composite restorations is often an issue. After reviewing several composite shade guides available on the market and outlining their main characteristics and limits (unrealistic specimen thickness, not made with the same material the clinician will use, only a few allow to overlap enamel tabs on dentin ones), the authors evaluated the reliability of a system designed to produce self-made standardized "tooth-shaped" shade guide specimens. Small changes in composite enamel thickness may determine huge differences in esthetic outcomes. In conclusion, the results showed that all the specimens demonstrated comparable enamel thickness in all the examined areas (cervical, middle, incisal).

  19. Development of a patient safety climate survey for Chinese hospitals: cross-national adaptation and psychometric evaluation.

    PubMed

    Zhu, Junya; Li, Liping; Zhao, Hailei; Han, Guangshu; Wu, Albert W; Weingart, Saul N

    2014-10-01

    Existing patient safety climate instruments, most of which have been developed in the USA, may not accurately reflect the conditions in the healthcare systems of other countries. To develop and evaluate a patient safety climate instrument for healthcare workers in Chinese hospitals. Based on a review of existing instruments, expert panel review, focus groups and cognitive interviews, we developed items relevant to patient safety climate in Chinese hospitals. The draft instrument was distributed to 1700 hospital workers from 54 units in six hospitals in five Chinese cities between July and October 2011, and 1464 completed surveys were received. We performed exploratory and confirmatory factor analyses and estimated internal consistency reliability, within-unit agreement, between-unit variation, unit-mean reliability, correlation between multi-item composites, and association between the composites and two single items of perceived safety. The final instrument included 34 items organised into nine composites: institutional commitment to safety, unit management support for safety, organisational learning, safety system, adequacy of safety arrangements, error reporting, communication and peer support, teamwork and staffing. All composites had acceptable unit-mean reliabilities (≥0.74) and within-unit agreement (Rwg ≥0.71), and exhibited significant between-unit variation with intraclass correlation coefficients ranging from 9% to 21%. Internal consistency reliabilities ranged from 0.59 to 0.88 and were ≥0.70 for eight of the nine composites. Correlations between composites ranged from 0.27 to 0.73. All composites were positively and significantly associated with the two perceived safety items. The Chinese Hospital Survey on Patient Safety Climate demonstrates adequate dimensionality, reliability and validity. The integration of qualitative and quantitative methods is essential to produce an instrument that is culturally appropriate for Chinese hospitals. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. An overview of computational simulation methods for composite structures failure and life analysis

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.

    1993-01-01

    Three parallel computational simulation methods are being developed at the LeRC Structural Mechanics Branch (SMB) for composite structures failure and life analysis: progressive fracture CODSTRAN; hierarchical methods for high-temperature composites; and probabilistic evaluation. Results to date demonstrate that these methods are effective in simulating composite structures failure/life/reliability.

  1. Quality Control and Nondestructive Evaluation Techniques for Composites. Part 1. Overview of Characterization Techniques for Composite Reliability

    DTIC Science & Technology

    1982-05-01

    MONITORING AND MANAGEMENT , 34 7.0 NONDESTRUCTIVE EVALUATION ( NDE ) 37 8. 0 SURFACE NDE 44 9.0 PERFORMANCE AND PROOF TESTING 46 10.0 SUMMARY AND...Chemical Quality Assurance Testing 2. Processability Testing 3. Cure Monitoring and Management 4. Nondestructive Evaluation ( NDE ) 5. Performance and...the management concept for implementing the specific tests. Chemical analysis, nondestructive evaluation ( NDE ) and environmental fatigue testing of

  2. A Decentralized Compositional Framework for Dependable Decision Process in Self-Managed Cyber Physical Systems

    PubMed Central

    Hou, Kun-Mean; Zhang, Zhan

    2017-01-01

    Cyber Physical Systems (CPSs) need to interact with the changeable environment under various interferences. To provide continuous and high quality services, a self-managed CPS should automatically reconstruct itself to adapt to these changes and recover from failures. Such dynamic adaptation behavior introduces systemic challenges for CPS design, advice evaluation and decision process arrangement. In this paper, a formal compositional framework is proposed to systematically improve the dependability of the decision process. To guarantee the consistent observation of event orders for causal reasoning, this work first proposes a relative time-based method to improve the composability and compositionality of the timing property of events. Based on the relative time solution, a formal reference framework is introduced for self-managed CPSs, which includes a compositional FSM-based actor model (subsystems of CPS), actor-based advice and runtime decomposable decisions. To simplify self-management, a self-similar recursive actor interface is proposed for decision (actor) composition. We provide constraints and seven patterns for the composition of reliability and process time requirements. Further, two decentralized decision process strategies are proposed based on our framework, and we compare the reliability with the static strategy and the centralized processing strategy. The simulation results show that the one-order feedback strategy has high reliability, scalability and stability against the complexity of decision and random failure. This paper also shows a way to simplify the evaluation for dynamic system by improving the composability and compositionality of the subsystem. PMID:29120357

  3. A Decentralized Compositional Framework for Dependable Decision Process in Self-Managed Cyber Physical Systems.

    PubMed

    Zhou, Peng; Zuo, Decheng; Hou, Kun-Mean; Zhang, Zhan

    2017-11-09

    Cyber Physical Systems (CPSs) need to interact with the changeable environment under various interferences. To provide continuous and high quality services, a self-managed CPS should automatically reconstruct itself to adapt to these changes and recover from failures. Such dynamic adaptation behavior introduces systemic challenges for CPS design, advice evaluation and decision process arrangement. In this paper, a formal compositional framework is proposed to systematically improve the dependability of the decision process. To guarantee the consistent observation of event orders for causal reasoning, this work first proposes a relative time-based method to improve the composability and compositionality of the timing property of events. Based on the relative time solution, a formal reference framework is introduced for self-managed CPSs, which includes a compositional FSM-based actor model (subsystems of CPS), actor-based advice and runtime decomposable decisions. To simplify self-management, a self-similar recursive actor interface is proposed for decision (actor) composition. We provide constraints and seven patterns for the composition of reliability and process time requirements. Further, two decentralized decision process strategies are proposed based on our framework, and we compare the reliability with the static strategy and the centralized processing strategy. The simulation results show that the one-order feedback strategy has high reliability, scalability and stability against the complexity of decision and random failure. This paper also shows a way to simplify the evaluation for dynamic system by improving the composability and compositionality of the subsystem.

  4. Development of Valid and Reliable Measures of Patient and Family Experiences of Hospice Care for Public Reporting.

    PubMed

    Anhang Price, Rebecca; Stucky, Brian; Parast, Layla; Elliott, Marc N; Haas, Ann; Bradley, Melissa; Teno, Joan M

    2018-03-20

    Increasingly, dying patients and their families have a choice of hospice providers. Care quality varies considerably across providers; informing consumers of these differences may help to improve their selection of hospices. To develop and evaluate standardized survey measures of hospice care experiences for the purpose of comparing and publicly reporting hospice performance. We assessed item performance and constructed composite measures by factor analysis, evaluating item-scale correlations and estimating reliability. To assess key drivers of overall experiences, we regressed overall rating and willingness to recommend the hospice on each composite. Data submitted by 2500 hospices participating in national implementation of the Consumer Assessment of Healthcare Providers and Systems (CAHPS ® ) Hospice Survey for April through September 2015. Composite measures of Hospice Team Communication, Getting Timely Care, Treating Family Member with Respect, Getting Emotional and Religious Support, Getting Help for Symptoms, and Getting Hospice Care Training. Cronbach's alpha estimates for the composite measures range from 0.61 to 0.85; hospice-level reliability for the measures range from 0.67 to 0.81 assuming 200 completed surveys per hospice. Together, the composites are responsible for 48% of the variance in caregivers' overall ratings of hospices. Hospice Team Communication is the strongest predictor of overall rating of care. Our analyses provide evidence of the reliability and validity of CAHPS Hospice Survey measure scores. Results also highlight important opportunities to improve the quality of hospice care, particularly with regard to addressing symptoms of anxiety and sadness, discussing side effects of pain medicine, and keeping family informed of the patient's condition.

  5. Infrared thermographic evaluation of marine composite structures

    NASA Astrophysics Data System (ADS)

    Jones, Thomas S.

    1995-06-01

    Glass fiber composite materials have been used for many years in the construction of pleasure, cruising, and racing marine vessels. These vessels have demonstrated excellent performance characteristics and have been reliable in service. Even so, as with all material systems, they are subject to damage from accident, neglect, and abuse. Traditional nondestructive inspection approaches are not always fully effective for examining composite marine structures. Infrared imaging offers a particularly attractive approach for the inspection of composite material structures. Glass fiber composites frequently possess a combination of thermal properties that make them good candidates for infrared thermographic evaluation while other nondestructive evaluation approaches provide limited success. Infrared thermography combines the advantages of being nondestructive with the capability of rapidly inspecting wide surface areas.

  6. Evaluation of residual strength in the basalt fiber reinforced composites under impact damage

    NASA Astrophysics Data System (ADS)

    Kim, Yun-Hae; Lee, Jin-Woo; Moon, Kyung-Man; Yoon, Sung-Won; Baek, Tae-Sil; Hwang, Kwang-Il

    2015-03-01

    Composites are vulnerable to the impact damage by the collision as to the thickness direction, because composites are being manufactured by laminating the fiber. The understanding about the retained strength after the impact damage of the material is essential in order to secure the reliability of the structure design using the composites. In this paper, we have tried to evaluate the motion of the material according to the kinetic energy and potential energy and the retained strength after impact damage by testing the free fall test of the basalt fiber reinforced composite in the limelight as the environment friendly characteristic.

  7. Reliable Execution Based on CPN and Skyline Optimization for Web Service Composition

    PubMed Central

    Ha, Weitao; Zhang, Guojun

    2013-01-01

    With development of SOA, the complex problem can be solved by combining available individual services and ordering them to best suit user's requirements. Web services composition is widely used in business environment. With the features of inherent autonomy and heterogeneity for component web services, it is difficult to predict the behavior of the overall composite service. Therefore, transactional properties and nonfunctional quality of service (QoS) properties are crucial for selecting the web services to take part in the composition. Transactional properties ensure reliability of composite Web service, and QoS properties can identify the best candidate web services from a set of functionally equivalent services. In this paper we define a Colored Petri Net (CPN) model which involves transactional properties of web services in the composition process. To ensure reliable and correct execution, unfolding processes of the CPN are followed. The execution of transactional composition Web service (TCWS) is formalized by CPN properties. To identify the best services of QoS properties from candidate service sets formed in the TCSW-CPN, we use skyline computation to retrieve dominant Web service. It can overcome that the reduction of individual scores to an overall similarity leads to significant information loss. We evaluate our approach experimentally using both real and synthetically generated datasets. PMID:23935431

  8. Reliable execution based on CPN and skyline optimization for Web service composition.

    PubMed

    Chen, Liping; Ha, Weitao; Zhang, Guojun

    2013-01-01

    With development of SOA, the complex problem can be solved by combining available individual services and ordering them to best suit user's requirements. Web services composition is widely used in business environment. With the features of inherent autonomy and heterogeneity for component web services, it is difficult to predict the behavior of the overall composite service. Therefore, transactional properties and nonfunctional quality of service (QoS) properties are crucial for selecting the web services to take part in the composition. Transactional properties ensure reliability of composite Web service, and QoS properties can identify the best candidate web services from a set of functionally equivalent services. In this paper we define a Colored Petri Net (CPN) model which involves transactional properties of web services in the composition process. To ensure reliable and correct execution, unfolding processes of the CPN are followed. The execution of transactional composition Web service (TCWS) is formalized by CPN properties. To identify the best services of QoS properties from candidate service sets formed in the TCSW-CPN, we use skyline computation to retrieve dominant Web service. It can overcome that the reduction of individual scores to an overall similarity leads to significant information loss. We evaluate our approach experimentally using both real and synthetically generated datasets.

  9. Development and psychometric evaluation of the Core Nurse Resource Scale.

    PubMed

    Simpson, Michelle R

    2010-11-01

    To examine the factor structure, internal consistency reliability and concurrent-related validity of the Core Nurse Resource Scale. A cross-sectional survey study design was used to obtain a sample of 149 nurses and nursing staff [Registered Nurse (RNs), Licensed Practical Nurse (LPNs) and Certified Nursing Assistant (CNAs)] working in long-term care facilities. Exploratory factor analysis, Cronbach's alpha and bivariate correlations were used to evaluate validity and reliability. Exploratory factor analysis yielded a scale with 18 items on three factors, accounting for 52% of the variance in scores. Internal consistency reliability for the composite and Core Nurse Resource Scale factors ranged from 0.79 to 0.91. The Core Nurse Resource Scale composite scale and subscales correlated positively with a measure of work engagement (r=0.247-0.572). The initial psychometric evaluation of the Core Nurse Resource Scale demonstrates it is a sound measure. Further validity and reliability assessment will need to be explored and assessed among nurses and other nursing staff working in other practice settings. The intent of the Core Nurse Resource Scale is to evaluate the presence of physical, psychological and social resources of the nursing work environment, to identify workplaces at risk for disengaged (low work engagement) nursing staff and to provide useful diagnostic information to healthcare administrators interested in interventions to improve the nursing work environment. © 2010 The Author. Journal compilation © 2010 Blackwell Publishing Ltd.

  10. Probabilistic Assessment of Fracture Progression in Composite Structures

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.; Minnetyan, Levon; Mauget, Bertrand; Huang, Dade; Addi, Frank

    1999-01-01

    This report describes methods and corresponding computer codes that are used to evaluate progressive damage and fracture and to perform probabilistic assessment in built-up composite structures. Structural response is assessed probabilistically, during progressive fracture. The effects of design variable uncertainties on structural fracture progression are quantified. The fast probability integrator (FPI) is used to assess the response scatter in the composite structure at damage initiation. The sensitivity of the damage response to design variables is computed. The methods are general purpose and are applicable to stitched and unstitched composites in all types of structures and fracture processes starting from damage initiation to unstable propagation and to global structure collapse. The methods are demonstrated for a polymer matrix composite stiffened panel subjected to pressure. The results indicated that composite constituent properties, fabrication parameters, and respective uncertainties have a significant effect on structural durability and reliability. Design implications with regard to damage progression, damage tolerance, and reliability of composite structures are examined.

  11. [Critical revision of the available methods for evaluate the body composition in population-based and clinical studies].

    PubMed

    Rezende, Fabiane; Rosado, Lina; Franceschinni, Sylvia; Rosado, Gilberto; Ribeiro, Rita; Marins, João Carlos Bouzas

    2007-12-01

    The corporal composition evaluation is extremely important for the individual and population nutritional state diagnosis and for the establishment of appropriate clinical-nutritional conducts. An excess of body fat is frequently associated with important metabolic alterations and chronic diseases, such as diabetes, hypertension and dyslipidemia The availability of methods to assess body composition is essential to evaluate health status of individuals. There are several methods for the corporal composition analysis, and it is important to know the limitation of each one and his/her validity so that the obtained estimates are reliable and correctly interpreted. The purpose of this study was to revise the applicability of some nutritional state indicators and corporal composition evaluation methods, such as corporal mass index, waist circumference and waist-hip relation, skinfold measurements, bioelectrical impedance analysis and near-infrared interactance.

  12. Internal Consistency, Retest Reliability, and their Implications For Personality Scale Validity

    PubMed Central

    McCrae, Robert R.; Kurtz, John E.; Yamagata, Shinji; Terracciano, Antonio

    2010-01-01

    We examined data (N = 34,108) on the differential reliability and validity of facet scales from the NEO Inventories. We evaluated the extent to which (a) psychometric properties of facet scales are generalizable across ages, cultures, and methods of measurement; and (b) validity criteria are associated with different forms of reliability. Composite estimates of facet scale stability, heritability, and cross-observer validity were broadly generalizable. Two estimates of retest reliability were independent predictors of the three validity criteria; none of three estimates of internal consistency was. Available evidence suggests the same pattern of results for other personality inventories. Internal consistency of scales can be useful as a check on data quality, but appears to be of limited utility for evaluating the potential validity of developed scales, and it should not be used as a substitute for retest reliability. Further research on the nature and determinants of retest reliability is needed. PMID:20435807

  13. Nondestructive Evaluation for Aerospace Composites

    NASA Technical Reports Server (NTRS)

    Leckey, Cara; Cramer, Elliott; Perey, Daniel

    2015-01-01

    Nondestructive evaluation (NDE) techniques are important for enabling NASA's missions in space exploration and aeronautics. The expanded and continued use of composite materials for aerospace components and vehicles leads to a need for advanced NDE techniques capable of quantitatively characterizing damage in composites. Quantitative damage detection techniques help to ensure safety, reliability and durability of space and aeronautic vehicles. This presentation will give a broad outline of NASA's range of technical work and an overview of the NDE research performed in the Nondestructive Evaluation Sciences Branch at NASA Langley Research Center. The presentation will focus on ongoing research in the development of NDE techniques for composite materials and structures, including development of automated data processing tools to turn NDE data into quantitative location and sizing results. Composites focused NDE research in the areas of ultrasonics, thermography, X-ray computed tomography, and NDE modeling will be discussed.

  14. Nondestructive evaluation of composite materials - A design philosophy

    NASA Technical Reports Server (NTRS)

    Duke, J. C., Jr.; Henneke, E. G., II; Stinchcomb, W. W.; Reifsnider, K. L.

    1984-01-01

    Efficient and reliable structural design utilizing fiber reinforced composite materials may only be accomplished if the materials used may be nondestructively evaluated. There are two major reasons for this requirement: (1) composite materials are formed at the time the structure is fabricated and (2) at practical strain levels damage, changes in the condition of the material, that influence the structure's mechanical performance is present. The fundamental basis of such a nondestructive evaluation capability is presented. A discussion of means of assessing nondestructively the material condition as well as a damage mechanics theory that interprets the material condition in terms of its influence on the mechanical response, stiffness, strength and life is provided.

  15. Holistic Evaluation of Writing Samples for Placement in Post-Secondary English Composition Courses.

    ERIC Educational Resources Information Center

    Guerrero, Barry J.; Robison, Ruth E.

    A study was conducted by the Student Development Center of the University of Hawaii at Hilo to develop a writing placement procedure in a community college setting which would be practical, reliable, and valid. The key to this procedure was an English composition placement device that could help readers rate, holistically, writing samples written…

  16. Test-Retest Reliability and Practice Effects of the Stability Evaluation Test.

    PubMed

    Williams, Richelle M; Corvo, Matthew A; Lam, Kenneth C; Williams, Travis A; Gilmer, Lesley K; McLeod, Tamara C Valovich

    2017-01-17

    Postural control plays an essential role in concussion evaluation. The Stability Evaluation Test (SET) aims to objectively analyze postural control by measuring sway velocity on the NeuroCom's VSR portable force platform (Natus, San Carlos, CA). To assess the test-retest reliability and practice effects of the SET protocol. Cohort. Research Laboratory. Fifty healthy adults (males=20, females=30, age=25.30±3.60 years, height=166.60±12.80 cm, mass=68.80±13.90 kg). All participants completed four trials of the SET. Each trial consisted of six 20-second balance tests with eyes closed, under the following conditions: double-leg firm (DFi), single-leg firm (SFi), tandem firm (TFi), double-leg foam (DFo), single-leg foam (SFo), and tandem foam (TFo). Each trial was separated by a 5-minute seated rest period. The dependent variable was sway velocity (deg/sec), with lower values indicating better balance. Sway velocity was recorded for each of the six conditions as well as a composite score for each trial. Test-retest reliability was analyzed across four trials with Intraclass Correlation Coefficients. Practice effects analyzed with repeated measures analysis of variance, followed by Tukey post-hoc comparisons for any significant main effects (p<.05). Sway velocity reliability values were good to excellent: DFi (ICC=0.88;95%CI:0.81,0.92), SFi (ICC=0.75;95%CI:0.61,0.85), TFi (ICC=0.84;95%CI:0.75,0.90), DFo (ICC=0.83;95%CI:0.74,0.90), SFo (ICC=0.82;95%CI:0.72,0.89), TFo (ICC=0.81;95%CI:0.69,0.88), and composite score (ICC=0.93;95%CI:0.88,0.95). Significant practice effects (p<.05) were noted on the SFi, DFo, SFo, TFo conditions, and composite scores. Our results suggest the SET has good to excellent reliability for the assessment of postural control in healthy adults. Due to the practice effects noted, a familiarization session is recommended (i.e., all 6 conditions) prior to recording the data. Future studies should evaluate injured patients to determine meaningful change scores during various injuries.

  17. The MG Composite

    PubMed Central

    Burns, Ted M.; Conaway, Mark; Sanders, Donald B.

    2010-01-01

    Objective: To study the concurrent and construct validity and test-retest reliability in the practice setting of an outcome measure for myasthenia gravis (MG). Methods: Eleven centers participated in the validation study of the Myasthenia Gravis Composite (MGC) scale. Patients with MG were evaluated at 2 consecutive visits. Concurrent and construct validities of the MGC were assessed by evaluating MGC scores in the context of other MG-specific outcome measures. We used numerous potential indicators of clinical improvement to assess the sensitivity and specificity of the MGC for detecting clinical improvement. Test-retest reliability was performed on patients at the University of Virginia. Results: A total of 175 patients with MG were enrolled at 11 sites from July 1, 2008, to January 31, 2009. A total of 151 patients were seen in follow-up. Total MGC scores showed excellent concurrent validity with other MG-specific scales. Analyses of sensitivities and specificities of the MGC revealed that a 3-point improvement in total MGC score was optimal for signifying clinical improvement. A 3-point improvement in the MGC also appears to represent a meaningful improvement to most patients, as indicated by improved 15-item myasthenia gravis quality of life scale (MG-QOL15) scores. The psychometric properties were no better for an individualized subscore made up of the 2 functional domains that the patient identified as most important to treat. The test-retest reliability coefficient of the MGC was 98%, with a lower 95% confidence interval of 97%, indicating excellent test-retest reliability. Conclusions: The Myasthenia Gravis Composite is a reliable and valid instrument for measuring clinical status of patients with myasthenia gravis in the practice setting and in clinical trials. PMID:20439845

  18. Improving the residency admissions process by integrating a professionalism assessment: a validity and feasibility study.

    PubMed

    Bajwa, Nadia M; Yudkowsky, Rachel; Belli, Dominique; Vu, Nu Viet; Park, Yoon Soo

    2017-03-01

    The purpose of this study was to provide validity and feasibility evidence in measuring professionalism using the Professionalism Mini-Evaluation Exercise (P-MEX) scores as part of a residency admissions process. In 2012 and 2013, three standardized-patient-based P-MEX encounters were administered to applicants invited for an interview at the University of Geneva Pediatrics Residency Program. Validity evidence was gathered for P-MEX content (item analysis); response process (qualitative feedback); internal structure (inter-rater reliability with intraclass correlation and Generalizability); relations to other variables (correlations); and consequences (logistic regression to predict admission). To improve reliability, Kane's formula was used to create an applicant composite score using P-MEX, structured letter of recommendation (SLR), and structured interview (SI) scores. Applicant rank lists using composite scores versus faculty global ratings were compared using the Wilcoxon signed-rank test. Seventy applicants were assessed. Moderate associations were found between pairwise correlations of P-MEX scores and SLR (r = 0.25, P = .036), SI (r = 0.34, P = .004), and global ratings (r = 0.48, P < .001). Generalizability of the P-MEX using three cases was moderate (G-coefficient = 0.45). P-MEX scores had the greatest correlation with acceptance (r = 0.56, P < .001), were the strongest predictor of acceptance (OR 4.37, P < .001), and increased pseudo R-squared by 0.20 points. Including P-MEX scores increased composite score reliability from 0.51 to 0.74. Rank lists of applicants using composite score versus global rating differed significantly (z = 5.41, P < .001). Validity evidence supports the use of P-MEX scores to improve the reliability of the residency admissions process by improving applicant composite score reliability.

  19. An innovative and comprehensive technique to evaluate different measures of medication adherence: The network meta-analysis.

    PubMed

    Tonin, Fernanda S; Wiecek, Elyssa; Torres-Robles, Andrea; Pontarolo, Roberto; Benrimoj, Shalom Charlie I; Fernandez-Llimos, Fernando; Garcia-Cardenas, Victoria

    2018-05-19

    Poor medication adherence is associated with adverse health outcomes and higher costs of care. However, inconsistencies in the assessment of adherence are found in the literature. To evaluate the effect of different measures of adherence in the comparative effectiveness of complex interventions to enhance patients' adherence to prescribed medications. A systematic review with network meta-analysis was performed. Electronic searches for relevant pairwise meta-analysis including trials of interventions that aimed to improve medication adherence were performed in PubMed. Data extraction was conducted with eligible trials evaluating short-period adherence follow-up (until 3 months) using any measure of adherence: self-report, pill count, or MEMS (medication event monitoring system). To standardize the results obtained with these different measures, an overall composite measure and an objective composite measure were also calculated. Network meta-analyses for each measure of adherence were built. Rank order and surface under the cumulative ranking curve analyses (SUCRA) were performed. Ninety-one trials were included in the network meta-analyses. The five network meta-analyses demonstrated robustness and reliability. Results obtained for all measures of adherence were similar across them and to both composite measures. For both composite measures, interventions comprising economic + technical components were the best option (90% of probability in SUCRA analysis) with statistical superiority against almost all other interventions and against standard care (odds ratio with 95% credibility interval ranging from 0.09 to 0.25 [0.02, 0.98]). The use of network meta-analysis was reliable to compare different measures of adherence of complex interventions in short-periods follow-up. Analyses with longer follow-up periods are needed to confirm these results. Different measures of adherence produced similar results. The use of composite measures revealed reliable alternatives to establish a broader and more detailed picture of adherence. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Prediction of composites behavior undergoing an ATP process through data-mining

    NASA Astrophysics Data System (ADS)

    Martin, Clara Argerich; Collado, Angel Leon; Pinillo, Rubén Ibañez; Barasinski, Anaïs; Abisset-Chavanne, Emmanuelle; Chinesta, Francisco

    2018-05-01

    The need to characterize composite surfaces for distinct mechanical or physical processes leads to different manners of evaluate the state of the surface. During many manufacturing processes deformation occurs, thus hindering composite classification for fabrication processes. In this work we focus on the challenge of a priori identifying the surfaces' behavior in order to optimize manufacturing. We will propose and validate the curvature of the surface as a reliable parameter and we will develop a tool that allows the prediction of the surface behavior.

  1. Computed tomography for non-destructive evaluation of composites: Applications and correlations

    NASA Technical Reports Server (NTRS)

    Goldberg, B.; Hediger, L.; Noel, E.

    1985-01-01

    The state-of-the-art fabrication techniques for composite materials are such that stringent species-specific acceptance criteria must be generated to insure product reliability. Non-destructive evaluation techniques including computed tomography (CT), X-ray radiography (RT), and ultrasonic scanning (UT) are investigated and compared to determine their applicability and limitations to graphite epoxy, carbon-carbon, and carbon-phenolic materials. While the techniques appear complementary, CT is shown to provide significant, heretofore unattainable data. Finally, a correlation of NDE techniques to destructive analysis is presented.

  2. An evaluation of the influence of modifications of selected face elements on the reliability of composite drawings.

    PubMed

    Lewandowski, Z

    2004-01-01

    The modification of various face elements in a composite drawing influences its reliability in relation to the corresponding photograph. Changes in various face elements are the cause of this decrease in similarity, when examined by both sexes. The results of an initial test suggest: regardless of the observing subject's sex, the highest rated picture (regarded as the most similar one) was the original picture. The face with a shortened nose height (n-sn) was recognised as the least similar to the original. In the second test, this picture obtained the lowest number of points, irrespective of the examining subjects' sex. In the examining group of females, the picture with changed bigonial breadth (go-go) was rated low. In the group of males the picture with a shortened interocular breadth (en-en) appeared poorly reliable. In the case of females, the likeness of the composite drawing to the photograph is least affected by shortening of mouth breadth (ch-ch), whereas in males, by the decrease in nose breadth (al-al).

  3. Psychometric Properties of the Death Anxiety Scale-Extended among Patients with End-Stage Renal Disease.

    PubMed

    Sharif Nia, Hamid; Pahlevan Sharif, Saeed; Koocher, Gerald P; Yaghoobzadeh, Ameneh; Haghdoost, Ali Akbar; Mar Win, Ma Thin; Soleimani, Mohammad Ali

    2017-01-01

    This study aimed to evaluate the validity and reliability of the Persian version of Death Anxiety Scale-Extended (DAS-E). A total of 507 patients with end-stage renal disease completed the DAS-E. The factor structure of the scale was evaluated using exploratory factor analysis with an oblique rotation and confirmatory factor analysis. The content and construct validity of the DAS-E were assessed. Average variance extracted, maximum shared squared variance, and average shared squared variance were estimated to assess discriminant and convergent validity. Reliability was assessed using Cronbach's alpha coefficient (α = .839 and .831), composite reliability (CR = .845 and .832), Theta (θ = .893 and .867), and McDonald Omega (Ω = .796 and .743). The analysis indicated a two-factor solution. Reliability and discriminant validity of the factors was established. Findings revealed that the present scale was a valid and reliable instrument that can be used in assessment of death anxiety in Iranian patients with end-stage renal disease.

  4. Lightweight thermally efficient composite feedlines, preliminary design and evaluation. [for the space tug propulsion system

    NASA Technical Reports Server (NTRS)

    Spond, D. E.; Holzworth, R. E.; Hall, C. A.

    1974-01-01

    Six liquid hydrogen feedline design concepts were developed for the cryogenic space tug. The feedlines include composite and all-metal vacuum jacketed and non-vacuum jacketed concepts, and incorporate the latest technology developments in the areas of thermally efficient vacuum jacket end closures and standoffs, radiation shields in the vacuum annulus, thermal coatings, and lightweight dissimilar metal flanged joints. The feedline design concepts were evaluated on the basis of thermal performance, weight, cost, reliability, and reusability. It is shown that composite tubing provides improved thermal performance and reduced weight for each design concept considered. Approximately 12 kg (26 lb.) can be saved by the use of composite tubing for the LH2 feedline and the other propulsion lines in the space tug.

  5. Tensile failure criteria for fiber composite materials

    NASA Technical Reports Server (NTRS)

    Rosen, B. W.; Zweben, C. H.

    1972-01-01

    The analysis provides insight into the failure mechanics of these materials and defines criteria which serve as tools for preliminary design material selection and for material reliability assessment. The model incorporates both dispersed and propagation type failures and includes the influence of material heterogeneity. The important effects of localized matrix damage and post-failure matrix shear stress transfer are included in the treatment. The model is used to evaluate the influence of key parameters on the failure of several commonly used fiber-matrix systems. Analyses of three possible failure modes were developed. These modes are the fiber break propagation mode, the cumulative group fracture mode, and the weakest link mode. Application of the new model to composite material systems has indicated several results which require attention in the development of reliable structural composites. Prominent among these are the size effect and the influence of fiber strength variability.

  6. Associating gunpowder and residues from commercial ammunition using compositional analysis.

    PubMed

    MacCrehan, William A; Reardon, Michelle R; Duewer, David L

    2002-03-01

    Qualitatively identifying and quantitatively determining the additives in smokeless gunpowder to calculate a numerical propellant to stabilizer (P/S) ratio is a new approach to associate handgun-fired organic gunshot residues (OGSR) with unfired powder. In past work, the P/S values of handgun OGSR and cartridges loaded with known gunpowders were evaluated. In this study, gunpowder and residue samples were obtained from seven boxes of commercial 38 caliber ammunition with the goals of associating cartridges within a box and matching residues to unfired powders, based on the P/S value and the qualitative identity of the additives. Gunpowder samples from four of the seven boxes of ammunition could be easily differentiated. When visual comparisons of the cartridge powders were considered in addition to composition, powder samples from all seven boxes of ammunition could be reliably differentiated. Handgun OGSR was also collected and evaluated in bulk as well as for individual particles. In some cases, residues could be reliably differentiated based on P/S and additive identity. It was instructive to evaluate the composition of individual unfired gunpowder and OGSR particles. We determined that both the numerical centroid and dispersity of the P/S measurements provide information for associations and exclusions. Associating measurements from residue particles with those of residue samples collected from a test firing of the same weapon and ammunition appears to be a useful approach to account for any changes in composition that occur during the firing process.

  7. Differential Weighting for Subcomponent Measures of Integrated Clinical Encounter Scores Based on the USMLE Step 2 CS Examination: Effects on Composite Score Reliability and Pass-Fail Decisions.

    PubMed

    Park, Yoon Soo; Lineberry, Matthew; Hyderi, Abbas; Bordage, Georges; Xing, Kuan; Yudkowsky, Rachel

    2016-11-01

    Medical schools administer locally developed graduation competency examinations (GCEs) following the structure of the United States Medical Licensing Examination Step 2 Clinical Skills that combine standardized patient (SP)-based physical examination and the patient note (PN) to create integrated clinical encounter (ICE) scores. This study examines how different subcomponent scoring weights in a locally developed GCE affect composite score reliability and pass-fail decisions for ICE scores, contributing to internal structure and consequential validity evidence. Data from two M4 cohorts (2014: n = 177; 2015: n = 182) were used. The reliability of SP encounter (history taking and physical examination), PN, and communication and interpersonal skills scores were estimated with generalizability studies. Composite score reliability was estimated for varying weight combinations. Faculty were surveyed for preferred weights on the SP encounter and PN scores. Composite scores based on Kane's method were compared with weighted mean scores. Faculty suggested weighting PNs higher (60%-70%) than the SP encounter scores (30%-40%). Statistically, composite score reliability was maximized when PN scores were weighted at 40% to 50%. Composite score reliability of ICE scores increased by up to 0.20 points when SP-history taking (SP-Hx) scores were included; excluding SP-Hx only increased composite score reliability by 0.09 points. Classification accuracy for pass-fail decisions between composite and weighted mean scores was 0.77; misclassification was < 5%. Medical schools and certification agencies should consider implications of assigning weights with respect to composite score reliability and consequences on pass-fail decisions.

  8. Evaluation of Psychometric Properties of the Second Version of the Taqwa (Piety) Questionnaire in Bahasa Melayu.

    PubMed

    Seghatoleslam, Tahereh; Habil, Hussain; Hatim, Ahmad; Ardakani, Abolfazl; Ishak, Khafidz; Rashid, Rusdi

    2017-02-10

    The aim of the study is to evaluate the psychometric properties of the Bahasa Melayu version of the Taqwa (piety) questionnaire, used for the measurement of behaviour of Drug Dependency Syndrome (DDS), in Malay patients. A sample of 98 males with a psychiatric diagnosis (DSM-IV-R) as the DDS was randomly selected from Kajang Khafidz Polyclinic Kuala Lumpur, Malaysia. After receiving their agreement to attend the study, they completed the Taqwa (piety) questionnaire. The reliability was assessed by determining the Cronbach's [Formula: see text] to measure the consistency of related questions for all four dimensions (subscales), including individual, social, cognitional, and emotional Taqwa behaviour. In the next step to evaluate the composite reliability, convergent, and discrimination validity, a measurement model was determined via Conformity Factor Analysis (CFA) based on Partial List Square method (Smart- PLS Ver: 2M3). The reliability of four dimensions of the questionnaire was acceptable ([Formula: see text] correlated to each other. However, according to the CFA method, the items with low loading factor (<0.5) were excluded from each dimension. Item 24 and 35 that were related to individual Taqwa, and item 35 that belonged to emotional Taqwa were excluded from the analysis. The composite reliability and convergent, and discrimination validity were satisfied in all conformity factor loading that exceeded 0/05. The psychometric properties of the Taqwa questionnaire are acceptable, and the scale is a good instrument for assessing the Islamic attitude, beliefs, and behaviour of the Bahasa Melayu DDS patients.

  9. Evaluation of the physical properties of dental resin composites using optical fiber sensing technology.

    PubMed

    Rajan, Ginu; Shouha, Paul; Ellakwa, Ayman; Bhowmik, Kishore; Xi, Jiangtao; Prusty, Gangadhara

    2016-09-01

    The characterization of the physical properties of dental resin composites is fraught with difficulties relating to significant intra and inter test parameter variabilities and is relatively time consuming and expensive. The main aim of this study was to evaluate whether optical fiber Bragg grating (FBG) sensing system may become a viable tool to study dental material characteristics. Of particular focus was the potential for the system to demonstrate a multi parameter all-in-one feature. A miniature FBG was embedded in six different dental resin composites and employed as a sensor to evaluate linear polymerization shrinkage, thermal expansion and water sorption. Six commercially available dental composites with different filler types and volume are evaluated. The tests are repeated with three sets of samples. The curing characteristics and residual strain gradient exhibited by the cured dental composites were also observed and commented. Among the studied samples, SDR shows lowest polymerization shrinkage, while Beautifil FO3 shows the highest. The results also show clear distinction between particle filler type and fiber reinforcement based composites in their polymerization shrinkage properties. The agreement of the results with existing literatures show that FBG based system provides accurate results. Polymerization shrinkage rate of the samples are also obtained. Thermal expansion of the composites are measured using the FBG sensing method for the first time and is correlated with resin type, volume, filler type and glass transition temperature. The water sorption characteristics of the dental composite are also successfully measured using the FBG sensing method. The high level of repeatability and the low standard deviations shown in the results indicate good reliability with the use of FBG sensors. This study demonstrates how optical fiber technology can provide simple and reliable methods of measuring the critical physical properties of dental composites. In addition due to the embedding and preservation of the sensor within the samples multiple parameters can be tested for with the same sample. These features are expected to greatly assist material science researchers in dentistry as well as other biomedical fields. Of some interest the phenomenon of stress relaxation of dental composite at higher temperature was observed. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  10. An in vitro study of the effect of different restorative materials on the reliability of a veneering porcelain.

    PubMed

    Anderson, Matthew R; Chung, Kwok-Hung; Flinn, Brian D; Raigrodski, Ariel J

    2013-12-01

    Implant-supported, porcelain veneered restorations experience a greater rate of porcelain fracture than tooth-supported restorations. For completely edentulous patients, one approach to minimizing porcelain fracture is to use acrylic resin in the mandible, although its efficacy is unknown. The purpose of this study was to evaluate the reliability of a veneering porcelain fatigued with different restorative materials in vitro. Fifty-nine veneering porcelain disk specimens were fabricated by layering veneering porcelain on nickel-chromium base metal alloy disks. Four groups of different indenter materials fatigued the porcelain specimens: group WC, tungsten carbide served as a control; group FC, pressed leucite glass ceramic; group NHC, nanohybrid composite resin denture tooth; and group AR, unfilled acrylic resin denture tooth. Porcelain specimens were randomly divided into 4 groups (n=14). A step-stress accelerated life-testing model was used. Use-level probability Weibull plots were generated, and the reliability of each group was estimated for a theoretical completion of 50 000 cycles at 150 N. Nanohybrid composite resin and unfilled acrylic resin denture tooth groups had higher reliability than tungsten carbide and leucite glass ceramic groups. No significant differences existed between the reliability of the tungsten carbide and leucite glass ceramic groups and the nanohybrid composite resin and acrylic resin denture tooth groups. Veneering porcelain disk specimens fatigued with the unfilled acrylic resin and nanohybrid composite resin denture tooth indenters exhibited higher reliability than the specimens fatigued with either the tungsten carbide or leucite glass ceramic indenters. All of the veneering porcelain disk specimens failed with the same mode of fracture, although the surface posttest exhibited different fracture characteristics among specimens fatigued with the 4 different materials. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  11. Stochastic-Strength-Based Damage Simulation of Ceramic Matrix Composite Laminates

    NASA Technical Reports Server (NTRS)

    Nemeth, Noel N.; Mital, Subodh K.; Murthy, Pappu L. N.; Bednarcyk, Brett A.; Pineda, Evan J.; Bhatt, Ramakrishna T.; Arnold, Steven M.

    2016-01-01

    The Finite Element Analysis-Micromechanics Analysis Code/Ceramics Analysis and Reliability Evaluation of Structures (FEAMAC/CARES) program was used to characterize and predict the progressive damage response of silicon-carbide-fiber-reinforced reaction-bonded silicon nitride matrix (SiC/RBSN) composite laminate tensile specimens. Studied were unidirectional laminates [0] (sub 8), [10] (sub 8), [45] (sub 8), and [90] (sub 8); cross-ply laminates [0 (sub 2) divided by 90 (sub 2),]s; angled-ply laminates [plus 45 (sub 2) divided by -45 (sub 2), ]s; doubled-edge-notched [0] (sub 8), laminates; and central-hole laminates. Results correlated well with the experimental data. This work was performed as a validation and benchmarking exercise of the FEAMAC/CARES program. FEAMAC/CARES simulates stochastic-based discrete-event progressive damage of ceramic matrix composite and polymer matrix composite material structures. It couples three software programs: (1) the Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC), (2) the Ceramics Analysis and Reliability Evaluation of Structures Life Prediction Program (CARES/Life), and (3) the Abaqus finite element analysis program. MAC/GMC contributes multiscale modeling capabilities and micromechanics relations to determine stresses and deformations at the microscale of the composite material repeating-unit-cell (RUC). CARES/Life contributes statistical multiaxial failure criteria that can be applied to the individual brittle-material constituents of the RUC, and Abaqus is used to model the overall composite structure. For each FEAMAC/CARES simulation trial, the stochastic nature of brittle material strength results in random, discrete damage events that incrementally progress until ultimate structural failure.

  12. Melt-infiltrated Sic Composites for Gas Turbine Engine Applications

    NASA Technical Reports Server (NTRS)

    Morscher, Gregory N.; Pujar, Vijay V.

    2004-01-01

    SiC-SiC ceramic matrix composites (CMCs) manufactured by the slurry -cast melt-infiltration (MI) process are leading candidates for many hot-section turbine engine components. A collaborative program between Goodrich Corporation and NASA-Glenn Research Center is aimed at determining and optimizing woven SiC/SiC CMC performance and reliability. A variety of composites with different fiber types, interphases and matrix compositions have been fabricated and evaluated. Particular focus of this program is on the development of interphase systems that will result in improved intermediate temperature stressed-oxidation properties of this composite system. The effect of the different composite variations on composite properties is discussed and, where appropriate, comparisons made to properties that have been generated under NASA's Ultra Efficient Engine Technology (UEET) Program.

  13. Probabilistic Multi-Scale, Multi-Level, Multi-Disciplinary Analysis and Optimization of Engine Structures

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.; Abumeri, Galib H.

    2000-01-01

    Aircraft engines are assemblies of dynamically interacting components. Engine updates to keep present aircraft flying safely and engines for new aircraft are progressively required to operate in more demanding technological and environmental requirements. Designs to effectively meet those requirements are necessarily collections of multi-scale, multi-level, multi-disciplinary analysis and optimization methods and probabilistic methods are necessary to quantify respective uncertainties. These types of methods are the only ones that can formally evaluate advanced composite designs which satisfy those progressively demanding requirements while assuring minimum cost, maximum reliability and maximum durability. Recent research activities at NASA Glenn Research Center have focused on developing multi-scale, multi-level, multidisciplinary analysis and optimization methods. Multi-scale refers to formal methods which describe complex material behavior metal or composite; multi-level refers to integration of participating disciplines to describe a structural response at the scale of interest; multidisciplinary refers to open-ended for various existing and yet to be developed discipline constructs required to formally predict/describe a structural response in engine operating environments. For example, these include but are not limited to: multi-factor models for material behavior, multi-scale composite mechanics, general purpose structural analysis, progressive structural fracture for evaluating durability and integrity, noise and acoustic fatigue, emission requirements, hot fluid mechanics, heat-transfer and probabilistic simulations. Many of these, as well as others, are encompassed in an integrated computer code identified as Engine Structures Technology Benefits Estimator (EST/BEST) or Multi-faceted/Engine Structures Optimization (MP/ESTOP). The discipline modules integrated in MP/ESTOP include: engine cycle (thermodynamics), engine weights, internal fluid mechanics, cost, mission and coupled structural/thermal, various composite property simulators and probabilistic methods to evaluate uncertainty effects (scatter ranges) in all the design parameters. The objective of the proposed paper is to briefly describe a multi-faceted design analysis and optimization capability for coupled multi-discipline engine structures optimization. Results are presented for engine and aircraft type metrics to illustrate the versatility of that capability. Results are also presented for reliability, noise and fatigue to illustrate its inclusiveness. For example, replacing metal rotors with composites reduces the engine weight by 20 percent, 15 percent noise reduction, and an order of magnitude improvement in reliability. Composite designs exist to increase fatigue life by at least two orders of magnitude compared to state-of-the-art metals.

  14. Long-term reliability of ImPACT in professional ice hockey.

    PubMed

    Echemendia, Ruben J; Bruce, Jared M; Meeuwisse, Willem; Comper, Paul; Aubry, Mark; Hutchison, Michael

    2016-02-01

    This study sought to assess the test-retest reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) across 2-4 year time intervals and evaluate the utility of a newly proposed two-factor (Speed/Memory) model of ImPACT across multiple language versions. Test-retest data were collected from non-concussed National Hockey League (NHL) players across 2-, 3-, and 4-year time intervals. The two-factor model was examined using different language versions (English, French, Czech, Swedish) of the test using a one-year interval, and across 2-4 year intervals using the English version of the test. The two-factor Speed index improved reliability across multiple language versions of ImPACT. The Memory factor also improved but reliability remained below the traditional cutoff of .70 for use in clinical decision-making. ImPACT reliabilities remained low (below .70) regardless of whether the four-composite or the two-factor model was used across 2-, 3-, and 4-year time intervals. The two-factor approach increased ImPACT's one-year reliability over the traditional four-composite model among NHL players. The increased stability in test scores improves the test's ability to detect cognitive changes following injury, which increases the diagnostic utility of the test and allows for better return to play decision-making by reducing the risk of exposing an athlete to additional trauma while the brain may be at a heightened vulnerability to such trauma. Although the Speed Index increases the clinical utility of the test, the stability of the Memory index remains low. Irrespective of whether the two-factor or traditional four-composite approach is used, these data suggest that new baselines should occur on a yearly basis in order to maximize clinical utility.

  15. Sample size planning for composite reliability coefficients: accuracy in parameter estimation via narrow confidence intervals.

    PubMed

    Terry, Leann; Kelley, Ken

    2012-11-01

    Composite measures play an important role in psychology and related disciplines. Composite measures almost always have error. Correspondingly, it is important to understand the reliability of the scores from any particular composite measure. However, the point estimates of the reliability of composite measures are fallible and thus all such point estimates should be accompanied by a confidence interval. When confidence intervals are wide, there is much uncertainty in the population value of the reliability coefficient. Given the importance of reporting confidence intervals for estimates of reliability, coupled with the undesirability of wide confidence intervals, we develop methods that allow researchers to plan sample size in order to obtain narrow confidence intervals for population reliability coefficients. We first discuss composite reliability coefficients and then provide a discussion on confidence interval formation for the corresponding population value. Using the accuracy in parameter estimation approach, we develop two methods to obtain accurate estimates of reliability by planning sample size. The first method provides a way to plan sample size so that the expected confidence interval width for the population reliability coefficient is sufficiently narrow. The second method ensures that the confidence interval width will be sufficiently narrow with some desired degree of assurance (e.g., 99% assurance that the 95% confidence interval for the population reliability coefficient will be less than W units wide). The effectiveness of our methods was verified with Monte Carlo simulation studies. We demonstrate how to easily implement the methods with easy-to-use and freely available software. ©2011 The British Psychological Society.

  16. Application of low-coherence interferometry for in situ nondestructive evaluation of thin and thick multilayered transparent composites

    NASA Astrophysics Data System (ADS)

    Khomenko, Anton; Cloud, Gary Lee; Haq, Mahmoodul

    2015-12-01

    Multilayered transparent composites having laminates with polymer interlayers and backing sheets are commonly used in a wide range of applications where visibility, transparency, impact resistance, and safety are essential. Manufacturing flaws or damage during operation can seriously compromise both safety and performance. Most fabrication defects are not discernible until after the entire multilayered transparent composite assembly has been completed, and in-the-field inspection for damage is a problem not yet solved. A robust and reliable nondestructive evaluation (NDE) technique is needed to evaluate structural integrity and identify defects that result from manufacturing issues as well as in-service damage arising from extreme environmental conditions in addition to normal mechanical and thermal loads. Current optical techniques have limited applicability for NDE of such structures. This work presents a technique that employs a modified interferometer utilizing a laser diode or femtosecond fiber laser source to acquire in situ defect depth location inside a thin or thick multilayered transparent composite, respectively. The technique successfully located various defects inside examined composites. The results show great potential of the technique for defect detection, location, and identification in multilayered transparent composites.

  17. Injection repair of carbon fiber/bismaleimide composite panels with bisphenol E cyanate ester resin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thunga, Mahendra; Bauer, Amy; Obusek, Kristine

    2014-08-01

    Resin injection of bisphenol E cyanate ester, a low viscosity resin that cures into a high temperature thermoset polymer, is investigated as a reliable repair method to restore strength and stiffness in delaminated carbon fiber/bismaleimide composites used in aircraft panels. The influence of temperature on the viscosity of the uncured resin was measured to optimize the injection conditions for high resin infiltration into the delaminations. The repair efficiency of the resin was evaluated by varying the panel thickness and the method by which the delamination damage was created in the composite specimens. Ultrasonic scanning (C-scan), flash thermography images, and cross-sectionmore » analysis of repaired panels revealed excellent resin infiltration into the damaged region. Evaluation of mechanical repair efficiency using both bending stiffness and in-plain compressive strength of the composite panels as the repair metrics showed values exceeding 100%.« less

  18. Carbon Fiber Reinforced Ceramic Composites for Propulsion Applications

    NASA Technical Reports Server (NTRS)

    Freedman, Marc (Technical Monitor); Shivakumar, Kunigal N.

    2003-01-01

    Fiber reinforced ceramic composites are materials of choice for gas turbine engines because of their high thermal efficiency, thrust/weight ratio, and operating temperatures. However, the successful introduction of ceramic composites to hot structures is limited because of excessive cost of manufacturing, reproducibility, nonuniformity, and reliability. Intense research is going on around the world to address some of these issues. The proposed effort is to develop a comprehensive status report of the technology on processing, testing, failure mechanics, and environmental durability of carbon fiber reinforced ceramic composites through extensive literature study, vendor and end-user survey, visits to facilities doing this type of work, and interviews. Then develop a cooperative research plan between NASA GRC and NCA&T (Center for Composite Materials Research) for processing, testing, environmental protection, and evaluation of fiber reinforced ceramic composites.

  19. Test-retest reliability of a standardized psychiatric interview (DIS/CIDI).

    PubMed

    Semler, G; Wittchen, H U; Joschke, K; Zaudig, M; von Geiso, T; Kaiser, S; von Cranach, M; Pfister, H

    1987-01-01

    The reliability of DSM-III diagnoses using an expanded version of the Diagnostic Interview Schedule (DIS), called the Composite International Diagnostic Interview (CIDI), was evaluated by examining 60 psychiatric inpatients on a test-retest basis. Acceptable agreement coefficients of (kappa) 0.5 or above were found for all but two disorders: dysthymic disorder and generalized anxiety disorder. The subclassification of DSM-III affective disorders also revealed some discrepancies between the test and the retest interviews. When compared with results from earlier versions of the DIS, diagnostic reliability was found to have improved for the DSM-III anxiety disorders in particular. These improvements can possibly be attributed to some changes in the wording of the respective items of this section. Several reasons for lowered test-retest reliability are discussed.

  20. Redesign of the System for Evaluation of Teaching Qualities in Anesthesiology Residency Training (SETQ Smart).

    PubMed

    Lombarts, Kiki M J M H; Ferguson, Andrew; Hollmann, Markus W; Malling, Bente; Arah, Onyebuchi A

    2016-11-01

    Given the increasing international recognition of clinical teaching as a competency and regulation of residency training, evaluation of anesthesiology faculty teaching is needed. The System for Evaluating Teaching Qualities (SETQ) Smart questionnaires were developed for assessing teaching performance of faculty in residency training programs in different countries. This study investigated (1) the structure, (2) the psychometric qualities of the new tools, and (3) the number of residents' evaluations needed per anesthesiology faculty to use the instruments reliably. Two SETQ Smart questionnaires-for faculty self-evaluation and for resident evaluation of faculty-were developed. A multicenter survey was conducted among 399 anesthesiology faculty and 430 residents in six countries. Statistical analyses included exploratory factor analysis, reliability analysis using Cronbach α, item-total scale correlations, interscale correlations, comparison of composite scales to global ratings, and generalizability analysis to assess residents' evaluations needed per faculty. In total, 240 residents completed 1,622 evaluations of 247 faculty. The SETQ Smart questionnaires revealed six teaching qualities consisting of 25 items. Cronbach α's were very high (greater than 0.95) for the overall SETQ Smart questionnaires and high (greater than 0.80) for the separate teaching qualities. Interscale correlations were all within the acceptable range of moderate correlation. Overall, questionnaire and scale scores correlated moderately to highly with the global ratings. For reliable feedback to individual faculty, three to five resident evaluations are needed. The first internationally piloted questionnaires for evaluating individual anesthesiology faculty teaching performance can be reliably, validly, and feasibly used for formative purposes in residency training.

  1. Reliability and Construct Validity of the NEI VFQ-25 in a Subset of Patients With Geographic Atrophy From the Phase 2 Mahalo Study.

    PubMed

    Sivaprasad, Sobha; Tschosik, Elizabeth; Kapre, Audrey; Varma, Rohit; Bressler, Neil M; Kimel, Miriam; Dolan, Chantal; Silverman, David

    2018-06-01

    Geographic atrophy (GA) is an advanced form of age-related macular degeneration characterized by progressive, irreversible visual function loss. This analysis evaluates the psychometric properties of the 25-Item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) composite, near activity, and distance activity scores in patients with GA. Reliability and validity study. Reliability and validity were tested with NEI VFQ-25 data collected from 100 subjects with GA from United States' sites of the phase 2 Mahalo study of lampalizumab (ClinicalTrials.gov identifier: NCT01229215). Strong internal consistency and reproducibility were demonstrated for the NEI VFQ-25 composite (Cronbach's α, 0.95; intraclass correlation coefficient [ICC], 0.86), near activity (Cronbach's α, 0.84; ICC, 0.80), and distance activity (Cronbach's α, 0.84; ICC, 0.84) scores. Convergent validity with the binocular measures, Minnesota Low-Vision Reading Test (MNRead) reading speed and Functional Reading Independence (FRI) index score, was demonstrated for baseline NEI VFQ-25 composite (Pearson correlation [r] = 0.61 and 0.69, respectively), near activities (r = 0.69 and 0.73), and distance activities (r = 0.57 and 0.64) scores. Known-group validity testing for baseline mean NEI VFQ-25 scores (composite, near activities, and distance activities) showed differences between patients with mean maximum MNRead reading speed ≥ 80 vs < 80 words per minute, and between mean FRI index score ≥ 2.5 vs < 2.5 (all P < .0001). Psychometric evidence supports the NEI VFQ-25 as a reliable and valid cross-sectional measure of the impact of GA on patient visual function and vision-related quality of life. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Precipitation Strengthenable NiTiPd High Temperature Shape Memory Alloys

    NASA Technical Reports Server (NTRS)

    Bigelow, Glen; Garg, Anita; Benafan, Othmane; Noebe, Ronald; Gaydosh, Darrell; Padula, Santo, II

    2017-01-01

    In binary NiTi alloys, it has long been known that Ni-rich alloys can be heat treated to produce precipitates which both strengthen the matrix against dislocations and improve the behavior of the material under thermal and mechanical cycling. Within recent years, the same effect has been observed in Ni-rich NiTiHf high temperature shape memory alloys and heat treatment regimens have been defined which will reliably produce improved properties. In NiTiPd alloys, precipitation has also been observed, but studies are still underway to define reliable heat treatments and compositions which will provide a balance of strengthening and good thermomechanical properties. For this study, a series of NiTi-32 at.Pd alloys was produced to determine the effect of changing nickeltitanium content on the transformation behavior and heat treatability of the material. Samples were aged at temperatures between 350C and 450C for times up to 100 hours. Actuation type behavior was evaluated using uniaxial constant force thermal cycling (UCFTC) to determine the effect of composition and aging on the material behavior. TEMSEM was used to evaluate the microstructure and determine the types of precipitates formed. The correlation between composition, heat treat, microstructure, and thermomechanical behavior will be addressed and discussed.

  3. CCARES: A computer algorithm for the reliability analysis of laminated CMC components

    NASA Technical Reports Server (NTRS)

    Duffy, Stephen F.; Gyekenyesi, John P.

    1993-01-01

    Structural components produced from laminated CMC (ceramic matrix composite) materials are being considered for a broad range of aerospace applications that include various structural components for the national aerospace plane, the space shuttle main engine, and advanced gas turbines. Specifically, these applications include segmented engine liners, small missile engine turbine rotors, and exhaust nozzles. Use of these materials allows for improvements in fuel efficiency due to increased engine temperatures and pressures, which in turn generate more power and thrust. Furthermore, this class of materials offers significant potential for raising the thrust-to-weight ratio of gas turbine engines by tailoring directions of high specific reliability. The emerging composite systems, particularly those with silicon nitride or silicon carbide matrix, can compete with metals in many demanding applications. Laminated CMC prototypes have already demonstrated functional capabilities at temperatures approaching 1400 C, which is well beyond the operational limits of most metallic materials. Laminated CMC material systems have several mechanical characteristics which must be carefully considered in the design process. Test bed software programs are needed that incorporate stochastic design concepts that are user friendly, computationally efficient, and have flexible architectures that readily incorporate changes in design philosophy. The CCARES (Composite Ceramics Analysis and Reliability Evaluation of Structures) program is representative of an effort to fill this need. CCARES is a public domain computer algorithm, coupled to a general purpose finite element program, which predicts the fast fracture reliability of a structural component under multiaxial loading conditions.

  4. Reliability and life prediction of ceramic composite structures at elevated temperatures

    NASA Technical Reports Server (NTRS)

    Duffy, Stephen F.; Gyekenyesi, John P.

    1994-01-01

    Methods are highlighted that ascertain the structural reliability of components fabricated of composites with ceramic matrices reinforced with ceramic fibers or whiskers and subject to quasi-static load conditions at elevated temperatures. Each method focuses on a particular composite microstructure: whisker-toughened ceramics, laminated ceramic matrix composites, and fabric reinforced ceramic matrix composites. In addition, since elevated service temperatures usually involve time-dependent effects, a section dealing with reliability degradation as a function of load history has been included. A recurring theme throughout this chapter is that even though component failure is controlled by a sequence of many microfailure events, failure of ceramic composites will be modeled using macrovariables.

  5. Effects of core-to-dentin thickness ratio on the biaxial flexural strength, reliability, and fracture mode of bilayered materials of zirconia core (Y-TZP) and veneer indirect composite resins.

    PubMed

    Su, Naichuan; Liao, Yunmao; Zhang, Hai; Yue, Li; Lu, Xiaowen; Shen, Jiefei; Wang, Hang

    2017-01-01

    Indirect composite resins (ICR) are promising alternatives as veneering materials for zirconia frameworks. The effects of core-to-dentin thickness ratio (C/Dtr) on the mechanical property of bilayered veneer ICR/yttria-tetragonal zirconia polycrystalline (Y-TZP) core disks have not been previously studied. The purpose of this in vitro study was to assess the effects of C/Dtr on the biaxial flexural strength, reliability, and fracture mode of bilayered veneer ICR/ Y-TZP core disks. A total of 180 bilayered 0.6-mm-thick composite resin disks in core material and C/Dtr of 2:1, 1:1, and 1:2 were tested with either core material placed up or placed down for piston-on-3-ball biaxial flexural strength. The mean biaxial flexural strength, Weibull modulus, and fracture mode were measured to evaluate the variation trend of the biaxial flexural strength, reliability, and fracture mode of the bilayered disks with various C/Dtr. One-way analysis of variance (ANOVA) and chi-square tests were used to evaluate the variation tendency of fracture mode with the C/Dtr or material placed down during testing (α=.05). Light microscopy was used to identify the fracture mode. The mean biaxial flexural strength and reliability improved with the increase in C/Dtr when specimens were tested with the core material either up and down, and depended on the materials that were placed down during testing. The rates of delamination, Hertzian cone cracks, subcritical radial cracks, and number of fracture fragments partially depended on the C/Dtr and the materials that were placed down during testing. The biaxial flexural strength, reliability, and fracture mode in bilayered structures of Y-TZP core and veneer ICR depend on both the C/Dtr and the material that was placed down during testing. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Optimization of Adaptive Intraply Hybrid Fiber Composites with Reliability Considerations

    NASA Technical Reports Server (NTRS)

    Shiao, Michael C.; Chamis, Christos C.

    1994-01-01

    The reliability with bounded distribution parameters (mean, standard deviation) was maximized and the reliability-based cost was minimized for adaptive intra-ply hybrid fiber composites by using a probabilistic method. The probabilistic method accounts for all naturally occurring uncertainties including those in constituent material properties, fabrication variables, structure geometry, and control-related parameters. Probabilistic sensitivity factors were computed and used in the optimization procedures. For actuated change in the angle of attack of an airfoil-like composite shell structure with an adaptive torque plate, the reliability was maximized to 0.9999 probability, with constraints on the mean and standard deviation of the actuation material volume ratio (percentage of actuation composite material in a ply) and the actuation strain coefficient. The reliability-based cost was minimized for an airfoil-like composite shell structure with an adaptive skin and a mean actuation material volume ratio as the design parameter. At a O.9-mean actuation material volume ratio, the minimum cost was obtained.

  7. Non-destructive Evaluation of Bonds Between Fiberglass Composite and Metal

    NASA Technical Reports Server (NTRS)

    Zhao, Selina; Sonta, Kestutis; Perey, Daniel F.; Cramer, K. E.; Berger, Libby

    2015-01-01

    To assess the integrity and reliability of an adhesive joint in an automotive composite component, several non-destructive evaluation (NDE) methodologies are correlated to lap shear bond strengths. A glass-fabric-reinforced composite structure was bonded to a metallic structure with a two-part epoxy adhesive. Samples were subsequently cut and tested in shear, and flaws were found in some areas. This study aims to develop a reliable and portable NDE system for service-level adhesive inspection in the automotive industry. The results of the experimental investigation using several NDE methods are presented and discussed. Fiberglass-to-metal bonding is the ideal configuration for NDE via thermography using excitation with induction heating, due to the conductive metal and non-conductive glass-fiber-reinforced composites. Excitation can be either by a research-grade induction heater of highly defined frequency and intensity, or by a service-level heater, such as would be used for sealing windshields in a body shop. The thermographs thus produced can be captured via a high-resolution infrared camera, with principal component analysis and 2D spatial Laplacian processing. Alternatively, the thermographs can be captured by low resolution thermochromic microencapsulated liquid crystal film imaging, which needs no post-processing and can be very inexpensive. These samples were also examined with phased-array ultrasound. The NDE methods are compared to the lap shear values and to each other for approximate cost, accuracy, and time and level of expertise needed.

  8. ARABIC TRANSLATION AND ADAPTATION OF THE HOSPITAL CONSUMER ASSESSMENT OF HEALTHCARE PROVIDERS AND SYSTEMS (HCAHPS) PATIENT SATISFACTION SURVEY INSTRUMENT.

    PubMed

    Dockins, James; Abuzahrieh, Ramzi; Stack, Martin

    2015-01-01

    To translate and adapt an effective, validated, benchmarked, and widely used patient satisfaction measurement tool for use with an Arabic-speaking population. Translation of survey's items, survey administration process development, evaluation of reliability, and international benchmarking Three hundred-bed tertiary care hospital in Jeddah, Saudi Arabia. 645 patients discharged during 2011 from the hospital's inpatient care units. INTERVENTIONS; The Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) instrument was translated into Arabic, a randomized weekly sample of patients was selected, and the survey was administered via telephone during 2011 to patients or their relatives. Scores were compiled for each of the HCAHPS questions and then for each of the six HCAHPS clinical composites, two non-clinical items, and two global items. Clinical composite scores, as well as the two non-clinical and two global items were analyzed for the 645 respondents. Clinical composites were analyzed using Spearman's correlation coefficient and Cronbach's alpha to demonstrate acceptable internal consistency for these items and scales demonstrated acceptable internal consistency for the clinical composites. (Spearman's correlation coefficient = 0.327 - 0.750, P < 0.01; Cronbach's alpha = 0.516 - 0.851) All ten HCAHPS measures were compared quarterly to US national averages with results that closely paralleled the US benchmarks. . The Arabic translation and adaptation of the HCAHPS is a valid, reliable, and feasible tool for evaluation and benchmarking of inpatient satisfaction in Arabic speaking populations.

  9. New materials for high temperature turbines; ONERA's DS composites confronted with blade problems

    NASA Technical Reports Server (NTRS)

    Bibring, H.

    1977-01-01

    ONERA's refractory DS composites were cited as materials required for use in advanced aircraft turbines, operating at high temperatures. These materials were found to be reliable in the construction of turbine blades. Requirements for a blade material in aircraft turbines operating at higher temperatures were compared with the actual performance as found in COTAC DS composite testing. The structure and properties of the more fully developed 74 and 741 types were specified. High temperature structural stability, impact of thermal and mechanical fatigue, oxidation resistance and coating capability were thoroughly evaluated. The problem of cooling passages in DS eutectic blades is also outlined.

  10. Reliability and Generalizability of Ratings of Compositions.

    ERIC Educational Resources Information Center

    Lehmann, Rainer H.

    A total of 1,487 eleventh grade students from the Hamburg (West Germany) school system were asked to complete four writing assignments used in an International Association for the Evaluation of Educational Achievement (IEA) study of writing assessment. In analyzing the writing samples, the study focused on: (1) between-rater effects; (2)…

  11. Study on Distribution Reliability with Parallel and On-site Distributed Generation Considering Protection Miscoordination and Tie Line

    NASA Astrophysics Data System (ADS)

    Chaitusaney, Surachai; Yokoyama, Akihiko

    In distribution system, Distributed Generation (DG) is expected to improve the system reliability as its backup generation. However, DG contribution in fault current may cause the loss of the existing protection coordination, e.g. recloser-fuse coordination and breaker-breaker coordination. This problem can drastically deteriorate the system reliability, and it is more serious and complicated when there are several DG sources in the system. Hence, the above conflict in reliability aspect unavoidably needs a detailed investigation before the installation or enhancement of DG is done. The model of composite DG fault current is proposed to find the threshold beyond which existing protection coordination is lost. Cases of protection miscoordination are described, together with their consequences. Since a distribution system may be tied with another system, the issues of tie line and on-site DG are integrated into this study. Reliability indices are evaluated and compared in the distribution reliability test system RBTS Bus 2.

  12. Highly reliable field electron emitters produced from reproducible damage-free carbon nanotube composite pastes with optimal inorganic fillers.

    PubMed

    Kim, Jae-Woo; Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul; Ahn, Seungjoon; Song, Yoon-Ho

    2014-02-14

    Highly reliable field electron emitters were developed using a formulation for reproducible damage-free carbon nanotube (CNT) composite pastes with optimal inorganic fillers and a ball-milling method. We carefully controlled the ball-milling sequence and time to avoid any damage to the CNTs, which incorporated fillers that were fully dispersed as paste constituents. The field electron emitters fabricated by printing the CNT pastes were found to exhibit almost perfect adhesion of the CNT emitters to the cathode, along with good uniformity and reproducibility. A high field enhancement factor of around 10,000 was achieved from the CNT field emitters developed. By selecting nano-sized metal alloys and oxides and using the same formulation sequence, we also developed reliable field emitters that could survive high-temperature post processing. These field emitters had high durability to post vacuum annealing at 950 °C, guaranteeing survival of the brazing process used in the sealing of field emission x-ray tubes. We evaluated the field emitters in a triode configuration in the harsh environment of a tiny vacuum-sealed vessel and observed very reliable operation for 30 h at a high current density of 350 mA cm(-2). The CNT pastes and related field emitters that were developed could be usefully applied in reliable field emission devices.

  13. Highly reliable field electron emitters produced from reproducible damage-free carbon nanotube composite pastes with optimal inorganic fillers

    NASA Astrophysics Data System (ADS)

    Kim, Jae-Woo; Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul; Ahn, Seungjoon; Song, Yoon-Ho

    2014-02-01

    Highly reliable field electron emitters were developed using a formulation for reproducible damage-free carbon nanotube (CNT) composite pastes with optimal inorganic fillers and a ball-milling method. We carefully controlled the ball-milling sequence and time to avoid any damage to the CNTs, which incorporated fillers that were fully dispersed as paste constituents. The field electron emitters fabricated by printing the CNT pastes were found to exhibit almost perfect adhesion of the CNT emitters to the cathode, along with good uniformity and reproducibility. A high field enhancement factor of around 10 000 was achieved from the CNT field emitters developed. By selecting nano-sized metal alloys and oxides and using the same formulation sequence, we also developed reliable field emitters that could survive high-temperature post processing. These field emitters had high durability to post vacuum annealing at 950 °C, guaranteeing survival of the brazing process used in the sealing of field emission x-ray tubes. We evaluated the field emitters in a triode configuration in the harsh environment of a tiny vacuum-sealed vessel and observed very reliable operation for 30 h at a high current density of 350 mA cm-2. The CNT pastes and related field emitters that were developed could be usefully applied in reliable field emission devices.

  14. Quantification of uncertainties in the performance of smart composite structures

    NASA Technical Reports Server (NTRS)

    Shiao, Michael C.; Chamis, Christos C.

    1993-01-01

    A composite wing with spars, bulkheads, and built-in control devices is evaluated using a method for the probabilistic assessment of smart composite structures. Structural responses (such as change in angle of attack, vertical displacements, and stresses in regular plies with traditional materials and in control plies with mixed traditional and actuation materials) are probabilistically assessed to quantify their respective scatter. Probabilistic sensitivity factors are computed to identify those parameters that have a significant influence on a specific structural response. Results show that the uncertainties in the responses of smart composite structures can be quantified. Responses such as structural deformation, ply stresses, frequencies, and buckling loads in the presence of defects can be reliably controlled to satisfy specified design requirements.

  15. Validity and Reliability of Thai Version of the Foot and Ankle Ability Measure (FAAM) Subjective Form.

    PubMed

    Arunakul, Marut; Arunakul, Preeyaphan; Suesiritumrong, Chakhrist; Angthong, Chayanin; Chernchujit, Bancha

    2015-06-01

    Self-administered questionnaires have become an important aspect for clinical outcome assessment of foot and ankle-related problems. The Foot and Ankle Ability Measure (FAAM) subjective form is a region-specific questionnaire that is widely used and has sufficient validity and reliability from previous studies. Translate the original English version of FAAM into a Thai version and evaluate the validity and reliability of Thai FAAM in patients with foot and ankle-related problems. The FAAM subjective form was translated into Thai using forward-backward translation protocol. Afterward, reliability and validity were tested. Following responses from 60 consecutive patients on two questionnaires, the Thai FAAM subjective form and the short form (SF)-36, were used. The validity was tested by correlating the scores from both questionnaires. The reliability was adopted by measuring the test-retest reliability and internal consistency. Thai FAAM score including activity of daily life (ADL) and Sport subscale demonstrated the sufficient correlations with physical functioning (PF) and physical composite score (PCS) domains of the SF-36 (statistically significant with p < 0.001 level and ≥ 0.5 values). The result of reliability revealed highly intra-class correlation coefficient as 0.8 and 0.77, respectively from test-retest study. The internal consistency was strong (Cronbach alpha = 0.94 and 0.88, respectively). The Thai version of FAAM subjective form retained the characteristics of the original version and has proved a reliable evaluation instrument for patients with foot and ankle-related problems.

  16. Reliable change of the sensory organization test.

    PubMed

    Broglio, Steven P; Ferrara, Michael S; Sopiarz, Kay; Kelly, Michael S

    2008-03-01

    To establish the sensitivity and specificity of the NeuroCom Sensory Organization Test (SOT) and provide practitioners with cut-scores for clinical decision making using estimates of reliable change. Retrospective cohort study. Research laboratory. Healthy (n = 66) and concussed (n = 63) young adult participants. Postural control assessments on the NeuroCom SOT were completed twice (baseline and follow-up) for both groups. Postconcussion assessments were administered within 24 hours of injury diagnosis. The reliable change technique was used to calculated cut-scores for each SOT variable (composite balance; somatosensory, visual, and vestibular ratios) at the 95%, 90%, 85%, 80%, 75%, and 70% confidence interval levels. When cut-scores were applied to the post-concussion evaluations, sensitivity and specificity varied with SOT variable and confidence interval. An evaluation for change on one or more SOT variable resulted in the highest combined sensitivity (57%) and specificity (80%) at the 75% confidence interval. Use of reliable change scores to detect significant changes in performance on the SOT resulted in decreased sensitivity and improved specificity compared to a previous report. These findings indicate that some concussed athletes may not show large changes in postconcussion postural control and this postural control evaluation should not be used in exclusion of other assessment techniques. The postural control assessment should be combined with other evaluative measures to gain the highest sensitivity to concussive injuries.

  17. Assessing adherence to the evidence base in the management of poststroke dysphagia.

    PubMed

    Burton, Christopher; Pennington, Lindsay; Roddam, Hazel; Russell, Ian; Russell, Daphne; Krawczyk, Karen; Smith, Hilary A

    2006-01-01

    To evaluate the reliability and responsiveness to change of an audit tool to assess adherence to evidence of effectiveness in the speech and language therapy (SLT) management of poststroke dysphagia. The tool was used to review SLT practice as part of a randomized study of different education strategies. Medical records were audited before and after delivery of the trial intervention. Seventeen SLT departments in the north-west of England participated in the study. The assessment tool was used to assess the medical records of 753 patients before and 717 patients after delivery of the trial intervention across the 17 departments. A target of 10 records per department per month was sought, using systematic sampling with a random start. Inter- and intra-rater reliability were explored, together with the tool's internal consistency and responsiveness to change. The assessment tool had high face validity, although internal consistency was low (ra = 0.37). Composite scores on the tool were however responsive to differences between SLT departments. Both inter- and intra-rater reliability ranged from 'substantial' to 'near perfect' across all items. The audit tool has high face validity and measurement reliability. The use of a composite adherence score should, however, proceed with caution as internal consistency is low.

  18. Assessment of Metabolome Annotation Quality: A Method for Evaluating the False Discovery Rate of Elemental Composition Searches

    PubMed Central

    Matsuda, Fumio; Shinbo, Yoko; Oikawa, Akira; Hirai, Masami Yokota; Fiehn, Oliver; Kanaya, Shigehiko; Saito, Kazuki

    2009-01-01

    Background In metabolomics researches using mass spectrometry (MS), systematic searching of high-resolution mass data against compound databases is often the first step of metabolite annotation to determine elemental compositions possessing similar theoretical mass numbers. However, incorrect hits derived from errors in mass analyses will be included in the results of elemental composition searches. To assess the quality of peak annotation information, a novel methodology for false discovery rates (FDR) evaluation is presented in this study. Based on the FDR analyses, several aspects of an elemental composition search, including setting a threshold, estimating FDR, and the types of elemental composition databases most reliable for searching are discussed. Methodology/Principal Findings The FDR can be determined from one measured value (i.e., the hit rate for search queries) and four parameters determined by Monte Carlo simulation. The results indicate that relatively high FDR values (30–50%) were obtained when searching time-of-flight (TOF)/MS data using the KNApSAcK and KEGG databases. In addition, searches against large all-in-one databases (e.g., PubChem) always produced unacceptable results (FDR >70%). The estimated FDRs suggest that the quality of search results can be improved not only by performing more accurate mass analysis but also by modifying the properties of the compound database. A theoretical analysis indicates that FDR could be improved by using compound database with smaller but higher completeness entries. Conclusions/Significance High accuracy mass analysis, such as Fourier transform (FT)-MS, is needed for reliable annotation (FDR <10%). In addition, a small, customized compound database is preferable for high-quality annotation of metabolome data. PMID:19847304

  19. Evaluation of hospital outcomes: the relation between length-of-stay, readmission, and mortality in a large international administrative database.

    PubMed

    Lingsma, Hester F; Bottle, Alex; Middleton, Steve; Kievit, Job; Steyerberg, Ewout W; Marang-van de Mheen, Perla J

    2018-02-14

    Hospital mortality, readmission and length of stay (LOS) are commonly used measures for quality of care. We aimed to disentangle the correlations between these interrelated measures and propose a new way of combining them to evaluate the quality of hospital care. We analyzed administrative data from the Global Comparators Project from 26 hospitals on patients discharged between 2007 and 2012. We correlated standardized and risk-adjusted hospital outcomes on mortality, readmission and long LOS. We constructed a composite measure with 5 levels, based on literature review and expert advice, from survival without readmission and normal LOS (best) to mortality (worst outcome). This composite measure was analyzed using ordinal regression, to obtain a standardized outcome measure to compare hospitals. Overall, we observed a 3.1% mortality rate, 7.8% readmission rate (in survivors) and 20.8% long LOS rate among 4,327,105 admissions. Mortality and LOS were correlated at the patient and the hospital level. A patient in the upper quartile LOS had higher odds of mortality (odds ratio = 1.45, 95% confidence interval 1.43-1.47) than those in the lowest quartile. Hospitals with a high standardized mortality had higher proportions of long LOS (r = 0.79, p < 0.01). Readmission rates did not correlate with either mortality or long LOS rates. The interquartile range of the standardized ordinal composite outcome was 74-117. The composite outcome had similar or better reliability in ranking hospitals than individual outcomes. Correlations between different outcome measures are complex and differ between hospital- and patient-level. The proposed composite measure combines three outcomes in an ordinal fashion for a more comprehensive and reliable view of hospital performance than its component indicators.

  20. Evaluation of capillary zone electrophoresis for the determination of protein composition in therapeutic immunoglobulins and human albumins.

    PubMed

    Christians, Stefan; van Treel, Nadine Denise; Bieniara, Gabriele; Eulig-Wien, Annika; Hanschmann, Kay-Martin; Giess, Siegfried

    2016-07-01

    Capillary zone electrophoresis (CZE) provides an alternative means of separating native proteins on the basis of their inherent electrophoretic mobilities. The major advantage of CZE is the quantification by UV detection, circumventing the drawbacks of staining and densitometry in the case of gel electrophoresis methods. The data of this validation study showed that CZE is a reliable assay for the determination of protein composition in therapeutic preparations of human albumin and human polyclonal immunoglobulins. Data obtained by CZE are in line with "historical" data obtained by the compendial method, provided that peak integration is performed without time correction. The focus here was to establish a rapid and reliable test to substitute the current gel based zone electrophoresis techniques for the control of protein composition of human immunoglobulins or albumins in the European Pharmacopoeia. We believe that the more advanced and modern CZE method described here is a very good alternative to the procedures currently described in the relevant monographs. Copyright © 2016 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  1. Fracture mechanics methodology: Evaluation of structural components integrity

    NASA Astrophysics Data System (ADS)

    Sih, G. C.; de Oliveira Faria, L.

    1984-09-01

    The application of fracture mechanics to structural-design problems is discussed in lectures presented in the AGARD Fracture Mechanics Methodology course held in Lisbon, Portugal, in June 1981. The emphasis is on aeronautical design, and chapters are included on fatigue-life prediction for metals and composites, the fracture mechanics of engineering structural components, failure mechanics and damage evaluation of structural components, flaw-acceptance methods, and reliability in probabilistic design. Graphs, diagrams, drawings, and photographs are provided.

  2. Critical aspects for the reliable headspace analysis of plants cultivated in vitro.

    PubMed

    Maes, K; Vercammen, J; Pham-Tuan, H; Sandra, P; Debergh, P C

    2001-01-01

    Various factors controlling the recoveries of volatile organic compounds in vitro headspace analysis of tomato plants (Lycopersicon esculentum Mill. 'Moneymaker'), sampled using solid phase micro-extraction, were evaluated and optimised. The variations in composition of the headspaces were determined as a function of time, and following in vitro wounding of the plant.

  3. Processing and mechanical properties of metal-ceramic composites with controlled microstructure formed by reactive metal penetration

    NASA Astrophysics Data System (ADS)

    Ellerby, Donald Thomas

    1999-12-01

    Compared to monolithic ceramics, metal-reinforced ceramic composites offer the potential for improved toughness and reliability in ceramic materials. As such, there is significant scientific and commercial interest in the microstructure and properties of metal-ceramic composites. Considerable work has been conducted on modeling the toughening behavior of metal reinforcements in ceramics; however, there has been limited application and testing of these concepts on real systems. Composites formed by newly developed reactive processes now offer the flexibility to systematically control metal-ceramic composite microstructure, and to test some of the property models that have been proposed for these materials. In this work, the effects of metal-ceramic composite microstructure on resistance curve (R-curve) behavior, strength, and reliability were systematically investigated. Al/Al2O3 composites were formed by reactive metal penetration (RMP) of aluminum metal into aluminosilicate ceramic preforms. Processing techniques were developed to control the metal content, metal composition, and metal ligament size in the resultant composite microstructure. Quantitative stereology and microscopy were used to characterize the composite microstructures, and then the influence of microstructure on strength, toughness, R-curve behavior, and reliability, was investigated. To identify the strength limiting flaws in the composite microstructure, fractography was used to determine the failure origins. Additionally, the crack bridging tractions produced by the metal ligaments in metal-ceramic composites formed by the RMP process were modeled. Due to relatively large flaws and low bridging stresses in RMP composites, no dependence of reliability on R-curve behavior was observed. The inherent flaws formed during reactive processing appear to limit the strength and reliability of composites formed by the RMP process. This investigation has established a clear relationship between processing, microstructure, and properties in metal-ceramic composites formed by the RMP process. RMP composite properties are determined by the metal-ceramic composite microstructure (e.g., metal content and ligament size), which can be systematically varied by processing. Furthermore, relative to the ceramic preforms used to make the composites, metal-ceramic composites formed by RMP generally have improved properties and combinations of properties that make them more desirable for advanced engineering applications.

  4. Feasibility and Reliability of Body Composition Measurements in Adults with Severe Intellectual and Sensory Disabilities

    ERIC Educational Resources Information Center

    Waninge, A.; van der Weide, W.; Evenhuis, I. J.; van Wijck, R.; van der Schans, C. P.

    2009-01-01

    Background: Anthropometric measurements are widely used to reliably quantify body composition and to estimate risks of overweight in healthy subjects and in patients. However, information about the reliability of anthropometric measurements in subjects with severe intellectual and sensory disabilities is lacking. Objective: The purpose of this…

  5. Evaluation of bacterial communities belonging to natural whey starters for Grana Padano cheese by length heterogeneity-PCR.

    PubMed

    Lazzi, C; Rossetti, L; Zago, M; Neviani, E; Giraffa, G

    2004-01-01

    To detect bacteria present in controlled dairy ecosystems with defined composition by length-heterogeneity (LH)-PCR. LH-PCR allows to distinguish different organisms on the basis of natural variations in the length of 16S rRNA gene sequences. LH-PCR was applied to depict population structure of the lactic acid bacteria (LAB) species recoverable from Grana Padano cheese whey starters. Typical bacterial species present in the LAB community were evidenced and well discriminated. Small differences in species composition, e.g. the frequent finding of Streptococcus thermophilus and the constant presence of thermophilic lactobacilli (Lactobacillus helveticus, Lact. delbrueckii subsp. lactis/bulgaricus and Lact. fermentum) were reliably highlighted. Specificity of LH-PCR was confirmed by species-specific PCR from total DNA of the cultures. LH-PCR is a useful tool to monitor microbial composition and population dynamics in dairy starter cultures. When present, non-dominant bacterial species present in the whey starters, such as Strep. thermophilus, can easily be visualized and characterized without isolating and cultivating single strains. A similar approach can be applied to more complex dairy ecosystems such as milk or cheese curd. Community members and differences in population structure of controlled dairy ecosystems such as whey starters for hard cheeses can be evaluated and compared in a relative easy, fast, reliable and highly reproducible way.

  6. Probabilistic Analysis and Design of a Raked Wing Tip for a Commercial Transport

    NASA Technical Reports Server (NTRS)

    Mason Brian H.; Chen, Tzi-Kang; Padula, Sharon L.; Ransom, Jonathan B.; Stroud, W. Jefferson

    2008-01-01

    An approach for conducting reliability-based design and optimization (RBDO) of a Boeing 767 raked wing tip (RWT) is presented. The goal is to evaluate the benefits of RBDO for design of an aircraft substructure. A finite-element (FE) model that includes eight critical static load cases is used to evaluate the response of the wing tip. Thirteen design variables that describe the thickness of the composite skins and stiffeners are selected to minimize the weight of the wing tip. A strain-based margin of safety is used to evaluate the performance of the structure. The randomness in the load scale factor and in the strain limits is considered. Of the 13 variables, the wing-tip design was controlled primarily by the thickness of the thickest plies in the upper skins. The report includes an analysis of the optimization results and recommendations for future reliability-based studies.

  7. Benchmarking of Computational Models for NDE and SHM of Composites

    NASA Technical Reports Server (NTRS)

    Wheeler, Kevin; Leckey, Cara; Hafiychuk, Vasyl; Juarez, Peter; Timucin, Dogan; Schuet, Stefan; Hafiychuk, Halyna

    2016-01-01

    Ultrasonic wave phenomena constitute the leading physical mechanism for nondestructive evaluation (NDE) and structural health monitoring (SHM) of solid composite materials such as carbon-fiber-reinforced polymer (CFRP) laminates. Computational models of ultrasonic guided-wave excitation, propagation, scattering, and detection in quasi-isotropic laminates can be extremely valuable in designing practically realizable NDE and SHM hardware and software with desired accuracy, reliability, efficiency, and coverage. This paper presents comparisons of guided-wave simulations for CFRP composites implemented using three different simulation codes: two commercial finite-element analysis packages, COMSOL and ABAQUS, and a custom code implementing the Elastodynamic Finite Integration Technique (EFIT). Comparisons are also made to experimental laser Doppler vibrometry data and theoretical dispersion curves.

  8. Comparison of Metal-Backed Free-Space and Open-Ended Coaxial Probe Techniques for the Dielectric Characterization of Aeronautical Composites †

    PubMed Central

    López-Rodríguez, Patricia; Escot-Bocanegra, David; Poyatos-Martínez, David; Weinmann, Frank

    2016-01-01

    The trend in the last few decades is that current unmanned aerial vehicles are completely made of composite materials rather than metallic, such as carbon-fiber or fiberglass composites. From the electromagnetic point of view, this fact forces engineers and scientists to assess how these materials may affect their radar response or their electronics in terms of electromagnetic compatibility. In order to evaluate this, electromagnetic characterization of different composite materials has become a need. Several techniques exist to perform this characterization, all of them based on the utilization of different sensors for measuring different parameters. In this paper, an implementation of the metal-backed free-space technique, based on the employment of antenna probes, is utilized for the characterization of composite materials that belong to an actual drone. Their extracted properties are compared with those given by a commercial solution, an open-ended coaxial probe (OECP). The discrepancies found between both techniques along with a further evaluation of the methodologies, including measurements with a split-cavity resonator, conclude that the implemented free-space technique provides more reliable results for this kind of composites than the OECP technique. PMID:27347966

  9. Preliminary evaluation of adhesion strength measurement devices for ceramic/titanium matrix composite bonds

    NASA Technical Reports Server (NTRS)

    Pohlchuck, Bobby; Zeller, Mary V.

    1992-01-01

    The adhesive bond between ceramic cement and a titanium matrix composite substrate to be used in the National Aerospace Plane program is evaluated. Two commercially available adhesion testers, the Sebastian Adherence Tester and the CSEM REVETEST Scratch Tester, are evaluated to determine their suitability for quantitatively measuring adhesion strength. Various thicknesses of cements are applied to several substrates, and bond strengths are determined with both testers. The Sabastian Adherence Tester has provided limited data due to an interference from the sample mounting procedure, and has been shown to be incapable of distinguishing adhesion strength from tensile and shear properties of the cement itself. The data from the scratch tester has been found to be difficult to interpret due to the porosity and hardness of the cement. Recommendations are proposed for a more reliable adhesion test method.

  10. Resin composite repair for implant-supported crowns.

    PubMed

    Bonfante, Estevam A; Suzuki, Marcelo; Hirata, Ronaldo; Bonfante, Gerson; Fardin, Vinicius P; Coelho, Paulo G

    2017-08-01

    This study evaluated the reliability of implant-supported crowns repaired with resin composites. Fifty-four titanium abutments were divided in three groups (n = 18 each) to support resin nanoceramic molar crowns, as follows: (LU) (Lava Ultimate, 3M ESPE); LU repaired with either a direct or an indirect resin composite. Samples were subjected to mouth-motion accelerated-life testing in water (n = 18). Cumulative damage with a use stress of 300 N was used to plot Weibull curves for group comparison. Reliability was calculated for a mission of 100,000 cycles at 400 N load. Beta values were 0.83 for LU, 0.31 and 0.27 for LU repaired with Filtek and Ceramage, respectively. Weibull modulus for LU was 9.5 and η = 1047 N, m = 6.85, and η = 1002 N for LU repaired with Ceramage, and m = 4.65 and η = 766 N for LU repaired with Filtek (p < 0.10 between LU and LU repaired with Filtek). Reliability at 400 N was 100% for both LU and LU repaired with Ceramage which were significantly higher than LU Filtek repair (32%). LU restored crowns failed cohesively. Fractures were confined within the restored material, and detailed fractography is presented. The performance of resin nanoceramic material repaired with an indirect composite was maintained after accelerated-life testing compared to unrepaired controls. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1481-1489, 2017. © 2016 Wiley Periodicals, Inc.

  11. Comparing the Psychometric Properties of Two Physical Activity Self-Efficacy Instruments in Urban, Adolescent Girls: Validity, Measurement Invariance, and Reliability

    PubMed Central

    Voskuil, Vicki R.; Pierce, Steven J.; Robbins, Lorraine B.

    2017-01-01

    Aims: This study compared the psychometric properties of two self-efficacy instruments related to physical activity. Factorial validity, cross-group and longitudinal invariance, and composite reliability were examined. Methods: Secondary analysis was conducted on data from a group randomized controlled trial investigating the effect of a 17-week intervention on increasing moderate to vigorous physical activity among 5th–8th grade girls (N = 1,012). Participants completed a 6-item Physical Activity Self-Efficacy Scale (PASE) and a 7-item Self-Efficacy for Exercise Behaviors Scale (SEEB) at baseline and post-intervention. Confirmatory factor analyses for intervention and control groups were conducted with Mplus Version 7.4 using robust weighted least squares estimation. Model fit was evaluated with the chi-square index, comparative fit index, and root mean square error of approximation. Composite reliability for latent factors with ordinal indicators was computed from Mplus output using SAS 9.3. Results: Mean age of the girls was 12.2 years (SD = 0.96). One-third of the girls were obese. Girls represented a diverse sample with over 50% indicating black race and an additional 19% identifying as mixed or other race. Both instruments demonstrated configural invariance for simultaneous analysis of cross-group and longitudinal invariance based on alternative fit indices. However, simultaneous metric invariance was not met for the PASE or the SEEB instruments. Partial metric invariance for the simultaneous analysis was achieved for the PASE with one factor loading identified as non-invariant. Partial metric invariance was not met for the SEEB. Longitudinal scalar invariance was achieved for both instruments in the control group but not the intervention group. Composite reliability for the PASE ranged from 0.772 to 0.842. Reliability for the SEEB ranged from 0.719 to 0.800 indicating higher reliability for the PASE. Reliability was more stable over time in the control group for both instruments. Conclusions: Results suggest that the intervention influenced how girls responded to indicator items. Neither of the instruments achieved simultaneous metric invariance making it difficult to assess mean differences in PA self-efficacy between groups. PMID:28824487

  12. Characterising the reproducibility and reliability of dietary patterns among Yup'ik Alaska Native people.

    PubMed

    Ryman, Tove K; Boyer, Bert B; Hopkins, Scarlett; Philip, Jacques; O'Brien, Diane; Thummel, Kenneth; Austin, Melissa A

    2015-02-28

    FFQ data can be used to characterise dietary patterns for diet-disease association studies. In the present study, we evaluated three previously defined dietary patterns--'subsistence foods', market-based 'processed foods' and 'fruits and vegetables'--among a sample of Yup'ik people from Southwest Alaska. We tested the reproducibility and reliability of the dietary patterns, as well as the associations of these patterns with dietary biomarkers and participant characteristics. We analysed data from adult study participants who completed at least one FFQ with the Center for Alaska Native Health Research 9/2009-5/2013. To test the reproducibility of the dietary patterns, we conducted a confirmatory factor analysis (CFA) of a hypothesised model using eighteen food items to measure the dietary patterns (n 272). To test the reliability of the dietary patterns, we used the CFA to measure composite reliability (n 272) and intra-class correlation coefficients for test-retest reliability (n 113). Finally, to test the associations, we used linear regression (n 637). All factor loadings, except one, in CFA indicated acceptable correlations between foods and dietary patterns (r>0·40), and model-fit criteria were >0·90. Composite and test-retest reliability of the dietary patterns were, respectively, 0·56 and 0·34 for 'subsistence foods', 0·73 and 0·66 for 'processed foods', and 0·72 and 0·54 for 'fruits and vegetables'. In the multi-predictor analysis, the dietary patterns were significantly associated with dietary biomarkers, community location, age, sex and self-reported lifestyle. This analysis confirmed the reproducibility and reliability of the dietary patterns in the present study population. These dietary patterns can be used for future research and development of dietary interventions in this underserved population.

  13. Characterizing the Reproducibility and Reliability of Dietary Patterns among Yup’ik Alaska Native People

    PubMed Central

    Ryman, Tove K.; Boyer, Bert B.; Hopkins, Scarlett; Philip, Jacques; O’Brien, Diane; Thummel, Kenneth; Austin, Melissa A.

    2015-01-01

    Food frequency questionnaire (FFQ) data can be used to characterize dietary patterns for diet-disease association studies. Among a sample of Yup’ik people from Southwest Alaska, we evaluated three previously defined dietary patterns: “subsistence foods” and market-based “processed foods” and “fruits and vegetables”. We tested the reproducibility and reliability of the dietary patterns and tested associations of the patterns with dietary biomarkers and participant characteristics. We analyzed data from adult study participants who completed at least one FFQ with the Center for Alaska Native Health Research 9/2009–5/2013. To test reproducibility we conducted a confirmatory factor analysis (CFA) of a hypothesized model using 18 foods to measure the dietary patterns (n=272). To test the reliability of the dietary patterns, we used CFA to measure the composite reliability (n=272) and intraclass correlation coefficients for test-retest reliability (n=113). Finally, to test associations we used linear regression (n=637). All CFA factor loadings, except one, indicated acceptable correlations between foods and dietary patterns (r > 0.40) and model fit criteria were greater than 0.90. Composite and test-retest reliability of dietary patterns were respectively 0.56 and 0.34 for subsistence foods, 0.73 and 0.66 for processed foods, and 0.72 and 0.54 for fruits and vegetables. In the multi-predictor analysis, dietary patterns were significantly associated with dietary biomarkers, community location, age, sex, and self-reported lifestyle. This analysis confirmed the reproducibility and reliability of the dietary patterns in this study population. These dietary patterns can be used for future research and development of dietary interventions in this underserved population. PMID:25656871

  14. Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study

    PubMed Central

    Hashmi, Ali M.; Naz, Shahana; Asif, Aftab; Khawaja, Imran S.

    2016-01-01

    Objective: To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. Methods: After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. Results: The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. Conclusion: The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research. PMID:28083049

  15. Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study.

    PubMed

    Hashmi, Ali M; Naz, Shahana; Asif, Aftab; Khawaja, Imran S

    2016-01-01

    To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research.

  16. Electrical impedance myography in facioscapulohumeral muscular dystrophy.

    PubMed

    Statland, Jeffrey M; Heatwole, Chad; Eichinger, Katy; Dilek, Nuran; Martens, William B; Tawil, Rabi

    2016-10-01

    In this study we determined the reliability and validity of electrical impedance myography (EIM) in facioscapulohumeral muscular dystrophy (FSHD). We performed a prospective study of EIM on 16 bilateral limb and trunk muscles in 35 genetically defined and clinically affected FSHD patients (reliability testing on 18 patients). Summary scores based on body region were derived. Reactance and phase (50 and 100 kHz) were compared with measures of strength, FSHD disease severity, and functional outcomes. Participants were mostly men, mean age 53.0 years, and included a full range of severity. Limb and trunk muscles showed good to excellent reliability [intraclass correlation coefficients (ICC) 0.72-0.99]. Summary scores for the arm, leg, and trunk showed excellent reliability (ICC 0.89-0.98). Reactance was the most sensitive EIM parameter to a broad range of FSHD disease metrics. EIM is a reliable measure of muscle composition in FSHD that offers the possibility to serially evaluate affected muscles. Muscle Nerve 54: 696-701, 2016. © 2016 Wiley Periodicals, Inc.

  17. Quality Evaluation of Raw Moutan Cortex Using the AHP and Gray Correlation-TOPSIS Method

    PubMed Central

    Zhou, Sujuan; Liu, Bo; Meng, Jiang

    2017-01-01

    Background: Raw Moutan cortex (RMC) is an important Chinese herbal medicine. Comprehensive and objective quality evaluation of Chinese herbal medicine has been one of the most important issues in the modern herbs development. Objective: To evaluate and compare the quality of RMC using the weighted gray correlation- Technique for Order Preference by Similarity to an Ideal Solution (TOPSIS) method. Materials and Methods: The percentage composition of gallic acid, catechin, oxypaeoniflorin, paeoniflorin, quercetin, benzoylpaeoniflorin, paeonol in different batches of RMC was determined, and then adopting MATLAB programming to construct the gray correlation-TOPSIS assessment model for quality evaluation of RMC. Results: The quality evaluation results of model evaluation and objective evaluation were consistent, reliable, and stable. Conclusion: The model of gray correlation-TOPSIS can be well applied to the quality evaluation of traditional Chinese medicine with multiple components and has broad prospect in application. SUMMARY The experiment tries to construct a model to evaluate the quality of RMC using the weighted gray correlation- Technique for Order Preference by Similarity to an Ideal Solution (TOPSIS) method. Results show the model is reliable and provide a feasible way in evaluating quality of traditional Chinese medicine with multiple components. PMID:28839384

  18. Reliability and validity of abbreviated surveys derived from the National Eye Institute Visual Function Questionnaire: The Study of Osteoporotic Fractures

    PubMed Central

    Gergana, Kodjebacheva; Coleman, Anne L.; Ensrud, Kristine E.; Cauley, Jane A.; Yu, Fei; Stone, Katie L.; Pedula, Kathryn L.; Hochberg, Marc C.; Mangione, Carol M.

    2010-01-01

    Purpose To test the reliability and validity of questionnaires shortened from the National Eye Institute 25-item Vision Function Questionnaire (NEI VFQ-9 and NEI VFQ-8). Design A cross-sectional multi-center cohort study. Methods Reliability was assessed by Cronbach alpha coefficients. Validity was evaluated by studying the association of vision-targeted quality-of-life composite scores with objective visual function measurements. Study population: A total of 5,482 women between the ages of 65 and 100 years participated in the Year-10 clinic visit in the Study of Osteoporotic Fractures (SOF). A total of 3,631 women with complete data were included in the visual acuity (VA) and visual field (VF) analysis of the NEI VFQ-9, which is defined for those who care to drive. and 5,311 in the analysis of the NEI VFQ-8. To assess differences in prevalent eye diseases, which were ascertained for a random sample of SOF participants, 853 and 1,237 women were included in the NEI VFQ-9 and the NEI VFQ-8 analyses, respectively. Results Cronbach alpha coefficient for the NEI VFQ-9 scale was 0.83 and that of the NEI VFQ-8 was 0.84. Using both questionnaires, women with VA worse than 20/40 had lower composite scores compared to those with VA 20/40 or better (p<0.001). Participants with mild, moderate, and severe binocular VF loss had lower composite scores compared to those with no binocular VF loss (p<0.001).Compared to women without chronic eye diseases in both eyes, women with at least one chronic eye disease in at least one eye had lower composite scores. Conclusions Both questionnaires showed high reliability across items and validity with respect to clinical markers of eye disease Future research should compare the properties of these shortened surveys to those of the NEI VFQ-25. PMID:20103058

  19. Structural health monitoring in composite materials using frequency response methods

    NASA Astrophysics Data System (ADS)

    Kessler, Seth S.; Spearing, S. Mark; Atalla, Mauro J.; Cesnik, Carlos E. S.; Soutis, Constantinos

    2001-08-01

    Cost effective and reliable damage detection is critical for the utilization of composite materials in structural applications. Non-destructive evaluation techniques (e.g. ultrasound, radiography, infra-red imaging) are available for use during standard repair and maintenance cycles, however by comparison to the techniques used for metals these are relatively expensive and time consuming. This paper presents part of an experimental and analytical survey of candidate methods for the detection of damage in composite materials. The experimental results are presented for the application of modal analysis techniques applied to rectangular laminated graphite/epoxy specimens containing representative damage modes, including delamination, transverse ply cracks and through-holes. Changes in natural frequencies and modes were then found using a scanning laser vibrometer, and 2-D finite element models were created for comparison with the experimental results. The models accurately predicted the response of the specimems at low frequencies, but the local excitation and coalescence of higher frequency modes make mode-dependent damage detection difficult and most likely impractical for structural applications. The frequency response method was found to be reliable for detecting even small amounts of damage in a simple composite structure, however the potentially important information about damage type, size, location and orientation were lost using this method since several combinations of these variables can yield identical response signatures.

  20. Probabilistic Evaluation of Advanced Ceramic Matrix Composite Structures

    NASA Technical Reports Server (NTRS)

    Abumeri, Galib H.; Chamis, Christos C.

    2003-01-01

    The objective of this report is to summarize the deterministic and probabilistic structural evaluation results of two structures made with advanced ceramic composites (CMC): internally pressurized tube and uniformly loaded flange. The deterministic structural evaluation includes stress, displacement, and buckling analyses. It is carried out using the finite element code MHOST, developed for the 3-D inelastic analysis of structures that are made with advanced materials. The probabilistic evaluation is performed using the integrated probabilistic assessment of composite structures computer code IPACS. The affects of uncertainties in primitive variables related to the material, fabrication process, and loadings on the material property and structural response behavior are quantified. The primitive variables considered are: thermo-mechanical properties of fiber and matrix, fiber and void volume ratios, use temperature, and pressure. The probabilistic structural analysis and probabilistic strength results are used by IPACS to perform reliability and risk evaluation of the two structures. The results will show that the sensitivity information obtained for the two composite structures from the computational simulation can be used to alter the design process to meet desired service requirements. In addition to detailed probabilistic analysis of the two structures, the following were performed specifically on the CMC tube: (1) predicted the failure load and the buckling load, (2) performed coupled non-deterministic multi-disciplinary structural analysis, and (3) demonstrated that probabilistic sensitivities can be used to select a reduced set of design variables for optimization.

  1. Nondestructive Evaluation of Adhesive Bonds via Ultrasonic Phase Measurements

    NASA Technical Reports Server (NTRS)

    Haldren, Harold A.; Perey, Daniel F.; Yost, William T.; Cramer, K. Elliott; Gupta, Mool C.

    2016-01-01

    The use of advanced composites utilizing adhesively bonded structures offers advantages in weight and cost for both the aerospace and automotive industries. Conventional nondestructive evaluation (NDE) has proved unable to reliably detect weak bonds or bond deterioration during service life conditions. A new nondestructive technique for quantitatively measuring adhesive bond strength is demonstrated. In this paper, an ultrasonic technique employing constant frequency pulsed phased-locked loop (CFPPLL) circuitry to monitor the phase response of a bonded structure from change in thermal stress is discussed. Theoretical research suggests that the thermal response of a bonded interface relates well with the quality of the adhesive bond. In particular, the effective stiffness of the adhesive-adherent interface may be extracted from the thermal phase response of the structure. The sensitivity of the CFPPLL instrument allows detection of bond pathologies that have been previously difficult-to-detect. Theoretical results with this ultrasonic technique on single epoxy lap joint (SLJ) specimens are presented and discussed. This technique has the potential to advance the use of adhesive bonds - and by association, advanced composite structures - by providing a reliable method to measure adhesive bond strength, thus permitting more complex, lightweight, and safe designs.

  2. CRACK GROWTH ANALYSIS OF SOLID OXIDE FUEL CELL ELECTROLYTES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    S. Bandopadhyay; N. Nagabhushana

    2003-10-01

    Defects and Flaws control the structural and functional property of ceramics. In determining the reliability and lifetime of ceramics structures it is very important to quantify the crack growth behavior of the ceramics. In addition, because of the high variability of the strength and the relatively low toughness of ceramics, a statistical design approach is necessary. The statistical nature of the strength of ceramics is currently well recognized, and is usually accounted for by utilizing Weibull or similar statistical distributions. Design tools such as CARES using a combination of strength measurements, stress analysis, and statistics are available and reasonably wellmore » developed. These design codes also incorporate material data such as elastic constants as well as flaw distributions and time-dependent properties. The fast fracture reliability for ceramics is often different from their time-dependent reliability. Further confounding the design complexity, the time-dependent reliability varies with the environment/temperature/stress combination. Therefore, it becomes important to be able to accurately determine the behavior of ceramics under simulated application conditions to provide a better prediction of the lifetime and reliability for a given component. In the present study, Yttria stabilized Zirconia (YSZ) of 9.6 mol% Yttria composition was procured in the form of tubes of length 100 mm. The composition is of interest as tubular electrolytes for Solid Oxide Fuel Cells. Rings cut from the tubes were characterized for microstructure, phase stability, mechanical strength (Weibull modulus) and fracture mechanisms. The strength at operating condition of SOFCs (1000 C) decreased to 95 MPa as compared to room temperature strength of 230 MPa. However, the Weibull modulus remains relatively unchanged. Slow crack growth (SCG) parameter, n = 17 evaluated at room temperature in air was representative of well studied brittle materials. Based on the results, further work was planned to evaluate the strength degradation, modulus and failure in more representative environment of the SOFCs.« less

  3. Study on the repeatability of manufacturing nano-silica (SiO2) reinforced composite laminates

    NASA Astrophysics Data System (ADS)

    Prince Jeya Lal, L.; Ramesh, S.; Natarajan, Elango

    2018-04-01

    Repeatability to manufacture nano-silica reinforced composite laminates with consistent mechanical properties is studied. In this study, composite laminates are manufactured by hand layup and there after mechanical properties of the laminates are evaluated under tensile and flexural loading conditions. Composite laminates are fabricated and tested under equivalent conditions. Plain weave E-Glass fabric and epoxy LY556 are used as reinforcement and matrix. Nano-silica of size 17nm is used as filler. To enhance the reliability of composite characterization, utmost care is taken to avoid defects like voids, surface defects and under-saturations. Homogeneous distribution of nano silica in matrix is analyzed using TEM study. Inconsistencies in mechanical properties are quantified by coefficient of variation. In this study, the coefficient of variation is estimated in terms of break load for tensile test is 4.45 and for flexural test is 2.27 and is well within the limits.

  4. Noninteractive macroscopic reliability model for whisker-reinforced ceramic composites

    NASA Technical Reports Server (NTRS)

    Duffy, Stephen F.; Arnold, Steven M.

    1990-01-01

    Considerable research is underway in the field of material science focusing on incorporating silicon carbide whiskers into silicon nitride and alumina matrices. These composites show the requisite thermal stability and thermal shock resistance necessary for use as components in advanced gas turbines and heat exchangers. This paper presents a macroscopic noninteractive reliability model for whisker-reinforced ceramic composites. The theory is multiaxial and is applicable to composites that can be characterized as transversely isotropic. Enough processing data exists to suggest this idealization encompasses a significantly large class of fabricated components. A qualitative assessment of the model is made by presenting reliability surfaces in several different stress spaces and for different values of model parameters.

  5. Baseline Neurocognitive Performance and Clearance for Athletes to Return to Contact.

    PubMed

    Asken, Breton M; Clugston, James R; Snyder, Aliyah R; Bauer, Russell M

    2017-01-01

     Computerized neurocognitive assessments are commonly used to manage sport-related concussion. Variations in baseline performance may influence neurocognitive performance after injury as well as the amount of time needed for an athlete to be cleared for return to sport participation.  To investigate the relationship between mean baseline Immediate Post-Concussion Assessment and Cognitive Test (ImPACT) scores and postconcussion reliable decline as well as the association between postconcussion cognitive decline and days missed after injury.  Cross-sectional study.  University concussion databank.  A total of 84 collegiate athletes who sustained a concussion between 2008 and 2015 were studied. For each ImPACT composite score (verbal memory, visual memory, visual motor speed, reaction time), athletes were grouped based on the presence or absence of reliable decline and on the presence of reliable decline in 0, 1, 2, 3, or 4 cognitive domains.  Outcome measures were baseline ImPACT composite scores and days missed due to concussion.  Athletes with a reliable decline in visual memory scored higher on baseline visual memory than did athletes with no decline or an improvement (t 82 = -2.348, P = .021, d = 0.65). When comparing athletes who displayed a reliable decline with those who showed no change or an improvement in any composite score, days missed did not differ. The number of composite scores with a reliable decline demonstrated no main effect on days missed (P = .530).  Athletes who exhibited cognitive decline in most or all of the composite scores did not miss more days after injury than athletes with a decline in fewer or none of the composite scores. Athletes should be educated regarding the lack of association between baseline neurocognitive scores and the presence or absence of a reliable decline after concussion, as well as the fact that, on average, individuals with a reliable decline across multiple domains did not miss more time after concussion.

  6. Validation of the dutch version of the health education impact questionnaire (HEIQ) and comparison of the Dutch translation with the English, German and French HEIQ.

    PubMed

    Ammerlaan, Judy W; van Os-Medendorp, Harmieke; Sont, Jacob K; Elsworth, Gerald R; Osborne, Richard H

    2017-01-31

    The Health Education Impact Questionnaire (heiQ) evaluates the effectiveness of health education and self-management programs provided to people dealing with a wide range of conditions. Aim of this study was to translate, culturally adapt and validate the Dutch translation of the heiQ and to compare the results with the English, German and French translations. A systematic translation process was undertaken. Psychometric properties were studied among patients with arthritis, atopic dermatitis, food allergy and asthma (n = 286). Factorial validity using confirmatory factor analysis, item difficulty (D), item remainder correlation and composite reliability were conducted. Stability was tested using the intra-class correlation coefficient (ICC). Items were well understood and only minor language adjustments were required. Confirmatory fit indices were >0.95 and item difficulty was D ≥ 0.65 for all items in scales showing acceptable fit indices, except for the reversed Emotional distress scale. Composite reliability ranged between 0.67 and 0.85. Test-retest reliability (n = 93) ICC varied between 0.61 and 0.84. Comparisons with other translations showed comparable fit indices. A lower ICC on Self-monitoring and insight scale was observed. The Dutch translation of the heiQ was found to be well understood and user friendly by patients with Rheumatoid Arthritis, Atopic Dermatitis, Food allergy and asthma and to have robust psychometric properties for evaluating the impact of health education and self-management programs. Given the wide applications of the heiQ and the comparability of the Dutch results with the English, German and French version, the heiQ is a practical and useful questionnaire to evaluate the impact of self-management support programs in different countries and populations with different diseases.

  7. Electric service reliability cost/worth assessment in a developing country

    NASA Astrophysics Data System (ADS)

    Pandey, Mohan Kumar

    Considerable work has been done in developed countries to optimize the reliability of electric power systems on the basis of reliability cost versus reliability worth. This has yet to be considered in most developing countries, where development plans are still based on traditional deterministic measures. The difficulty with these criteria is that they cannot be used to evaluate the economic impacts of changing reliability levels on the utility and the customers, and therefore cannot lead to an optimum expansion plan for the system. The critical issue today faced by most developing countries is that the demand for electric power is high and growth in supply is constrained by technical, environmental, and most importantly by financial impediments. Many power projects are being canceled or postponed due to a lack of resources. The investment burden associated with the electric power sector has already led some developing countries into serious debt problems. This thesis focuses on power sector issues facing by developing countries and illustrates how a basic reliability cost/worth approach can be used in a developing country to determine appropriate planning criteria and justify future power projects by application to the Nepal Integrated Electric Power System (NPS). A reliability cost/worth based system evaluation framework is proposed in this thesis. Customer surveys conducted throughout Nepal using in-person interviews with approximately 2000 sample customers are presented. The survey results indicate that the interruption cost is dependent on both customer and interruption characteristics, and it varies from one location or region to another. Assessments at both the generation and composite system levels have been performed using the customer cost data and the developed NPS reliability database. The results clearly indicate the implications of service reliability to the electricity consumers of Nepal, and show that the reliability cost/worth evaluation is both possible and practical in a developing country. The average customer interruption costs of Rs 35/kWh at Hierarchical Level I and Rs 26/kWh at Hierarchical Level II evaluated in this research work led to an optimum reserve margin of 7.5%, which is considerably lower than the traditional reserve margin of 15% used in the NPS. A similar conclusion may result in other developing countries facing difficulties in power system expansion planning using the traditional approach. A new framework for system planning is therefore recommended for developing countries which would permit an objective review of the traditional system planning approach, and the evaluation of future power projects using a new approach based on fundamental principles of power system reliability and economics.

  8. Simulated space environmental effects on a polyetherimide and its carbon fiber-reinforced composites

    NASA Technical Reports Server (NTRS)

    Kern, Kristen T.; Stancil, Phillip C.; Harries, Wynford L.; Long, Edward R., Jr.; Thibeault, Sheila A.

    1993-01-01

    The selection of materials for spacecraft construction requires identification of candidate materials which can perform reliably in the space environment. Understanding the effects of the space environment on the materials is an important step in the selection of candidate materials. This work examines the effects of energetic electrons, thermal cycling, electron radiation in conjunction with thermal cycling, and atomic oxygen on a thermoplastic polyetherimide and its carbon-fiber-reinforced composites. Composite materials made with non-sized fibers as well as materials made with fibers sized with an epoxy were evaluated. The mechanical and thermomechanical properties of the materials were studied and spectroscopic techniques were used to investigate the mechanisms for the observed effects. Considerations for future material development are suggested.

  9. Environmental exposure effects on composite materials for commercial aircraft

    NASA Technical Reports Server (NTRS)

    Gibbons, M. N.

    1982-01-01

    The data base for composite materials' properties as they are affected by the environments encountered in operating conditions, both in flight and at ground terminals is expanded. Absorbed moisture degrades the mechanical properties of graphite/epoxy laminates at elevated temperatures. Since airplane components are frequently exposed to atmospheric moisture, rain, and accumulated water, quantitative data are required to evaluate the amount of fluids absorbed under various environmental conditions and the subsequent effects on material properties. In addition, accelerated laboratory test techniques are developed are reliably capable of predicting long term behavior. An accelerated environmental exposure testing procedure is developed, and experimental results are correlated and compared with analytical results to establish the level of confidence for predicting composite material properties.

  10. A Direct Method for Obtaining Approximate Standard Error and Confidence Interval of Maximal Reliability for Composites with Congeneric Measures

    ERIC Educational Resources Information Center

    Raykov, Tenko; Penev, Spiridon

    2006-01-01

    Unlike a substantial part of reliability literature in the past, this article is concerned with weighted combinations of a given set of congeneric measures with uncorrelated errors. The relationship between maximal coefficient alpha and maximal reliability for such composites is initially dealt with, and it is shown that the former is a lower…

  11. Composite Reliability and Standard Errors of Measurement for a Seven-Subtest Short Form of the Wechsler Adult Intelligence Scale-Revised.

    ERIC Educational Resources Information Center

    Schretlen, David; And Others

    1994-01-01

    Composite reliability and standard errors of measurement were computed for prorated Verbal, Performance, and Full-Scale intelligence quotient (IQ) scores from a seven-subtest short form of the Wechsler Adult Intelligence Scale-Revised. Results with 1,880 adults (standardization sample) indicate that this form is as reliable as the complete test.…

  12. Damage tolerance certification of a fighter horizontal stabilizer

    NASA Astrophysics Data System (ADS)

    Huang, Jia-Yen; Tsai, Ming-Yang; Chen, Jong-Sheng; Ong, Ching-Long

    1995-05-01

    A review of the program for the damage tolerance certification test of a composite horizontal stabilizer (HS) of a fighter is presented. The object of this program is to certify that the fatigue life and damage tolerance strength of a damaged composite horizontal stabilizer meets the design requirements. According to the specification for damage tolerance certification, a test article should be subjected to two design lifetimes of flight-by-flight load spectra simulating the in-service fatigue loading condition for the aircraft. However, considering the effect of environmental change on the composite structure, one additional lifetime test was performed. In addition, to evaluate the possibilities for extending the service life of the structure, one more lifetime test was carried out with the spectrum increased by a factor of 1.4. To assess the feasibility and reliability of repair technology on a composite structure, two damaged areas were repaired after two lifetimes of damage tolerance test. On completion of four lifetimes of the damage tolerance test, the static residual strength was measured to check whether structural strength after repair met the requirements. Stiffness and static strength of the composite HS with and without damage were evaluated and compared.

  13. Shear bond strength of indirect composite material to monolithic zirconia.

    PubMed

    Sari, Fatih; Secilmis, Asli; Simsek, Irfan; Ozsevik, Semih

    2016-08-01

    This study aimed to evaluate the effect of surface treatments on bond strength of indirect composite material (Tescera Indirect Composite System) to monolithic zirconia (inCoris TZI). Partially stabilized monolithic zirconia blocks were cut into with 2.0 mm thickness. Sintered zirconia specimens were divided into different surface treatment groups: no treatment (control), sandblasting, glaze layer & hydrofluoric acid application, and sandblasting + glaze layer & hydrofluoric acid application. The indirect composite material was applied to the surface of the monolithic zirconia specimens. Shear bond strength value of each specimen was evaluated after thermocycling. The fractured surface of each specimen was examined with a stereomicroscope and a scanning electron microscope to assess the failure types. The data were analyzed using one-way analysis of variance (ANOVA) and Tukey LSD tests (α=.05). Bond strength was significantly lower in untreated specimens than in sandblasted specimens (P<.05). No difference between the glaze layer and hydrofluoric acid application treated groups were observed. However, bond strength for these groups were significantly higher as compared with the other two groups (P<.05). Combined use of glaze layer & hydrofluoric acid application and silanization are reliable for strong and durable bonding between indirect composite material and monolithic zirconia.

  14. Communicative Access Measures for Stroke: Development and Evaluation of a Quality Improvement Tool.

    PubMed

    Kagan, Aura; Simmons-Mackie, Nina; Victor, J Charles; Chan, Melodie T

    2017-11-01

    To (1) develop a systems-level quality improvement tool targeting communicative access to information and decision-making for stroke patients with language disorders; and (2) evaluate the resulting tool-the Communicative Access Measures for Stroke (CAMS). Survey development and evaluation was in line with accepted guidelines and included item generation and reduction, survey formatting and composition, pretesting, pilot testing, and reliability assessment. Development and evaluation were carried out in hospital and community agency settings. The project used a convenience sample of 31 participants for the survey development, and 63 participants for the CAMS reliability study (broken down into 6 administrators/managers, 32 frontline staff, 25 participants with aphasia). Eligible participants invited to the reliability study included individuals from 45 community-based organizations in Ontario as well as 4400 individuals from communities of practice. Not applicable. Data were analyzed using kappa statistics and intraclass correlations for each item score on all surveys. A tool, the CAMS, comprising 3 surveys, was developed for health facilities from the perspectives of (1) administrators/policymakers, (2) staff/frontline health care providers, and (3) patients with aphasia (using a communicatively accessible version). Reliability for items on the CAMS-Administrator and CAMS-Staff surveys was moderate to high (kappa/intraclass correlation coefficients [ICCs], .54-1.00). As expected, reliability was lower for the CAMS-Patient survey, with most items having ICCs between 0.4 and 0.6. These findings suggest that CAMS may provide useful quality improvement information for health care facilities with an interest in improving care for patients with stroke and aphasia. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  15. Contaminants in landfill soils - Reliability of prefeasibility studies.

    PubMed

    Hölzle, Ingo

    2017-05-01

    Recent landfill mining studies have researched the potential for resource recovery using samples from core drilling or grab cranes. However, most studies used small sample numbers, which may not represent the heterogeneous landfill composition. As a consequence, there exists a high risk of an incorrect economic and/or ecological evaluation. The main objective of this work is to investigate the possibilities and limitations of preliminary investigations concerning the crucial soil composition. The preliminary samples of landfill investigations were compared to the excavation samples from three completely excavated landfills in Germany. In addition, the research compared the reliability of prediction of the two investigation methods, core drilling and grab crane. Sampling using a grab crane led to better results, even for smaller investigations of 10 samples. Analyses of both methods showed sufficiently accurate results to make predictions (standard error 5%, level of confidence 95%) for most heavy metals, cyanide and PAH in the dry substance and for sulphate, barium, Benzo[a]pyrene, pH and the electrical conductivity in leachate analyses of soil type waste. While chrome and nickel showed less accurate results, the concentrations of hydrocarbons, TOC, DOC, PCB and fluorine (leachate) were not predictable even for sample numbers of up to 59. Overestimations of pollutant concentrations were more frequently apparent in drilling, and underestimations when using a grab crane. The dispersion of the element and elemental composition had no direct impact on the reliability of prediction. Thus, an individual consideration of the particular element or elemental composition for dry substance and leachate analyses is recommended to adapt the sample strategy and calculate an optimum sample number. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Composite Overwrapped Pressure Vessels (COPV): Developing Flight Rationale for the Space Shuttle Program

    NASA Technical Reports Server (NTRS)

    Kezirian, Michael T.

    2010-01-01

    Introducing composite vessels into the Space Shuttle Program represented a significant technical achievement. Each Orbiter vehicle contains 24 (nominally) Kevlar tanks for storage of pressurized helium (for propulsion) and nitrogen (for life support). The use of composite cylinders saved 752 pounds per Orbiter vehicle compared with all-metal tanks. The weight savings is significant considering each Shuttle flight can deliver 54,000 pounds of payload to the International Space Station. In the wake of the Columbia accident and the ensuing Return to Flight activities, the Space Shuttle Program, in 2005, re-examined COPV hardware certification. Incorporating COPV data that had been generated over the last 30 years and recognizing differences between initial Shuttle Program requirements and current operation, a new failure mode was identified, as composite stress rupture was deemed credible. The Orbiter Project undertook a comprehensive investigation to quantify and mitigate this risk. First, the engineering team considered and later deemed as unfeasible the option to replace existing all flight tanks. Second, operational improvements to flight procedures were instituted to reduce the flight risk and the danger to personnel. Third, an Orbiter reliability model was developed to quantify flight risk. Laser profilometry inspection of several flight COPVs identified deep (up to 20 mil) depressions on the tank interior. A comprehensive analysis was performed and it confirmed that these observed depressions were far less than the criterion which was established as necessary to lead to liner buckling. Existing fleet vessels were exonerated from this failure mechanism. Because full validation of the Orbiter Reliability Model was not possible given limited hardware resources, an Accelerated Stress Rupture Test of a flown flight vessel was performed to provide increased confidence. A Bayesian statistical approach was developed to evaluate possible test results with respect to the model credibility and thus flight rationale for continued operation of the Space Shuttle with existing flight hardware. A non-destructive evaluation (NDE) technique utilizing Raman Spectroscopy was developed to directly measure the overwrap residual stress state. Preliminary results provide optimistic results that patterns of fluctuation in fiber elastic strains over the outside vessel surface could be directly correlated with increased fiber stress ratios and thus reduced reliability.

  17. Comprehensive drought characteristics analysis based on a nonlinear multivariate drought index

    NASA Astrophysics Data System (ADS)

    Yang, Jie; Chang, Jianxia; Wang, Yimin; Li, Yunyun; Hu, Hui; Chen, Yutong; Huang, Qiang; Yao, Jun

    2018-02-01

    It is vital to identify drought events and to evaluate multivariate drought characteristics based on a composite drought index for better drought risk assessment and sustainable development of water resources. However, most composite drought indices are constructed by the linear combination, principal component analysis and entropy weight method assuming a linear relationship among different drought indices. In this study, the multidimensional copulas function was applied to construct a nonlinear multivariate drought index (NMDI) to solve the complicated and nonlinear relationship due to its dependence structure and flexibility. The NMDI was constructed by combining meteorological, hydrological, and agricultural variables (precipitation, runoff, and soil moisture) to better reflect the multivariate variables simultaneously. Based on the constructed NMDI and runs theory, drought events for a particular area regarding three drought characteristics: duration, peak, and severity were identified. Finally, multivariate drought risk was analyzed as a tool for providing reliable support in drought decision-making. The results indicate that: (1) multidimensional copulas can effectively solve the complicated and nonlinear relationship among multivariate variables; (2) compared with single and other composite drought indices, the NMDI is slightly more sensitive in capturing recorded drought events; and (3) drought risk shows a spatial variation; out of the five partitions studied, the Jing River Basin as well as the upstream and midstream of the Wei River Basin are characterized by a higher multivariate drought risk. In general, multidimensional copulas provides a reliable way to solve the nonlinear relationship when constructing a comprehensive drought index and evaluating multivariate drought characteristics.

  18. Flexible Transparent Conductive Films with High Performance and Reliability Using Hybrid Structures of Continuous Metal Nanofiber Networks for Flexible Optoelectronics.

    PubMed

    Park, Juyoung; Hyun, Byung Gwan; An, Byeong Wan; Im, Hyeon-Gyun; Park, Young-Geun; Jang, Junho; Park, Jang-Ung; Bae, Byeong-Soo

    2017-06-21

    We report an Ag nanofiber-embedded glass-fabric reinforced hybrimer (AgNF-GFRHybrimer) composite film as a reliable and high-performance flexible transparent conducting film. The continuous AgNF network provides superior optoelectronic properties of the composite film by minimizing transmission loss and junction resistance. In addition, the excellent thermal/chemical stability and mechanical durability of the GFRHybrimer matrix provides enhanced mechanical durability and reliability of the final AgNF-GFRHybrimer composite film. To demonstrate the availability of our AgNF-GFRHybrimer composite as a transparent conducting film, we fabricated a flexible organic light-emitting diode (OLED) device on the AgNF-GFRHybrimer film; the OLED showed stable operation during a flexing.

  19. Lightweight thermally efficient composite feedlines for the space tug cryogenic propulsion system

    NASA Technical Reports Server (NTRS)

    Spond, D. E.

    1975-01-01

    Six liquid hydrogen feedline design concepts were developed for the cryogenic space tug. The feedlines include composite and all-metal vacuum jacketed and nonvacuum jacketed concepts, and incorporate the latest technological developments in the areas of thermally efficient vacuum jacket end closures and standoffs, radiation shields in the vacuum annulus, thermal coatings, and lightweight dissimilar metal flanged joints. The feedline design concepts are evaluated on the basis of thermal performance, weight, cost, reliability, and reusability. Design concepts were proved in a subscale test program. Detail design was completed on the most promising composite feedline concept and an all-metal feedline. Three full scale curved composite feedlines and one all-metal feedline assembly were fabricated and subjected to a test program representative of flight hardware qualification. The test results show that composite feedline technology is fully developed. Composite feedlines are ready for space vehicle application and offer significant reduction in weights over the conventional all-metal feedlines presently used.

  20. Fiber optics reflectance spectroscopy (45°x: 45°) for color analysis of dental composite.

    PubMed

    Gargano, Marco; Ludwig, Nicola; Federighi, Veronica; Sykes, Ros; Lodi, Giovanni; Sardella, Andrea; Carrassi, Antonio; Varoni, Elena M

    2016-08-01

    To evaluate the application of a fiber optic reflectance spectroscopy (FORS) prototype probe for 45°x: 45° FORS for determining color of dental materials. A portable spectrophotometer with a highly manageable fiber optics co-axial probe was used to apply 45°x: 45° FORS for color matching in restorative dentistry. The color coordinates in CIELAB space of two dental shade guides and of the corresponding photopolymerized composites were collected and compared. The 45°x: 45° FORS with the co-axial probe (test system), the integrating sphere spectroscopy (reference system) and a commercial dental colorimeter (comparator system) were used to collect data and calculate color differences (ΔE and ΔE00). FORS system displayed high repeatability, reproducibility and accuracy. ΔE and ΔE00 values between the shade-guide, each other, and the corresponding composites resulted above the clinically acceptable limit. The 45°x: 45° FORS test system demonstrated suitable in vitro performance for dental composite color evaluation. 45°x: 45° fiber optic reflectance spectroscopy allows reliable color analysis of small surfaces of dental composites, favoring the color matching of material with the closely surrounding dental tissue, and confirming significant color differences between shade guide tabs and photo-polymerized composites.

  1. Constructing the 'Best' Reliability Data for the Job - Developing Generic Reliability Data from Alternative Sources Early in a Product's Development Phase

    NASA Technical Reports Server (NTRS)

    Kleinhammer, Roger K.; Graber, Robert R.; DeMott, D. L.

    2016-01-01

    Reliability practitioners advocate getting reliability involved early in a product development process. However, when assigned to estimate or assess the (potential) reliability of a product or system early in the design and development phase, they are faced with lack of reasonable models or methods for useful reliability estimation. Developing specific data is costly and time consuming. Instead, analysts rely on available data to assess reliability. Finding data relevant to the specific use and environment for any project is difficult, if not impossible. Instead, analysts attempt to develop the "best" or composite analog data to support the assessments. Industries, consortia and vendors across many areas have spent decades collecting, analyzing and tabulating fielded item and component reliability performance in terms of observed failures and operational use. This data resource provides a huge compendium of information for potential use, but can also be compartmented by industry, difficult to find out about, access, or manipulate. One method used incorporates processes for reviewing these existing data sources and identifying the available information based on similar equipment, then using that generic data to derive an analog composite. Dissimilarities in equipment descriptions, environment of intended use, quality and even failure modes impact the "best" data incorporated in an analog composite. Once developed, this composite analog data provides a "better" representation of the reliability of the equipment or component. It can be used to support early risk or reliability trade studies, or analytical models to establish the predicted reliability data points. It also establishes a baseline prior that may updated based on test data or observed operational constraints and failures, i.e., using Bayesian techniques. This tutorial presents a descriptive compilation of historical data sources across numerous industries and disciplines, along with examples of contents and data characteristics. It then presents methods for combining failure information from different sources and mathematical use of this data in early reliability estimation and analyses.

  2. Overlap in genomic variation associated with milk fat composition in Holstein Friesian and Dutch native dual-purpose breeds.

    PubMed

    Maurice-Van Eijndhoven, M H T; Bovenhuis, H; Veerkamp, R F; Calus, M P L

    2015-09-01

    The aim of this study was to identify if genomic variations associated with fatty acid (FA) composition are similar between the Holstein-Friesian (HF) and native dual-purpose breeds used in the Dutch dairy industry. Phenotypic and genotypic information were available for the breeds Meuse-Rhine-Yssel (MRY), Dutch Friesian (DF), Groningen White Headed (GWH), and HF. First, the reliability of genomic breeding values of the native Dutch dual-purpose cattle breeds MRY, DF, and GWH was evaluated using single nucleotide polymorphism (SNP) effects estimated in HF, including all SNP or subsets with stronger associations in HF. Second, the genomic variation of the regions associated with FA composition in HF (regions on Bos taurus autosome 5, 14, and 26), were studied in the different breeds. Finally, similarities in genotype and allele frequencies between MRY, DF, GWH, and HF breeds were assessed for specific regions associated with FA composition. On average across the traits, the highest reliabilities of genomic prediction were estimated for GWH (0.158) and DF (0.116) when the 8 to 22 SNP with the strongest association in HF were included. With the same set of SNP, GEBV for MRY were the least reliable (0.022). This indicates that on average only 2 (MRY) to 16% (GWH) of the genomic variation in HF is shared with the native Dutch dual-purpose breeds. The comparison of predicted variances of different regions associated with milk and milk fat composition showed that breeds clearly differed in genomic variation within these regions. Finally, the correlations of allele frequencies between breeds across the 8 to 22 SNP with the strongest association in HF were around 0.8 between the Dutch native dual-purpose breeds, whereas the correlations between the native breeds and HF were clearly lower and around 0.5. There was no consistent relationship between the reliabilities of genomic prediction for a specific breed and the correlation between the allele frequencies of this breed and HF. In conclusion, most of the genomic variation associated with FA composition in the Dutch dual-purpose breeds appears to be breed-specific. Furthermore, the minor allele frequencies of genes having an effect on the milk FA composition in HF were shown to be much smaller in the breeds MRY, DF, and GWH, especially for the MRY breed. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Iterative fitting method for the evaluation and quantification of PAES spectra

    NASA Astrophysics Data System (ADS)

    Zimnik, Samantha; Hackenberg, Mathias; Hugenschmidt, Christoph

    2017-01-01

    The elemental composition of surfaces is of great importance for the understanding of many surface processes such as catalysis. For a reliable analysis and a comparison of results, the quantification of the measured data is indispensable. Positron annihilation induced Auger Electron Spectroscopy (PAES) is a spectroscopic technique that measures the elemental composition with outstanding surface sensitivity, but up to now, no standardized evaluation procedure for PAES spectra is available. In this paper we present a new approach for the evaluation of PAES spectra of compounds, using the spectra obtained for the pure elements as reference. The measured spectrum is then fitted by a linear combination of the reference spectra by varying their intensities. The comparison of the results of the fitting routine with a calculation of the full parameter range shows an excellent agreement. We present the results of the new analysis method to evaluate the PAES spectra of sub-monolayers of Ni on a Pd substrate.

  4. PubMed

    Steagall, Paulo V M; Monteiro, Beatriz P; Lavoie, Anne-Marie; Frank, Diane; Troncy, Eric; Luna, Stelio P L; Brondani, Juliana T

    2017-01-01

    Validation of the French version of the UNESP-Botucatu multidimensional composite pain scale for assessing postoperative pain in cats. The aim of this study was to validate the French version of the UNESP-Botucatu multidimensional composite pain scale (MCPS-Fr) to assess postoperative pain in cats. Two veterinarians and one DVM student identified three domains of behavior based on video analyses: "psychomotor change", "protection of the painful area" and "physiological variables". Internal consistency was excellent (Cronbach's alpha coefficient of 0.94, 0.90 and 0.61, respectively). Criterion validity was good to very good when evaluations from the three observers were compared with a "gold standard". Inter- and intra-rater reliability for each scale item were good to very good. The optimal cut-off point identified with a ROC curve was > 7 (scale range 0-30 points), with a sensitivity of 97.8% and specificity of 99.1%. The MCPS-Fr is a valid, reliable and responsive instrument for assessing acute pain in cats undergoing ovariohysterectomy.(Translated by Dr. Beatriz Monteiro).

  5. Assessment of NDE Reliability Data

    NASA Technical Reports Server (NTRS)

    Yee, B. G. W.; Chang, F. H.; Couchman, J. C.; Lemon, G. H.; Packman, P. F.

    1976-01-01

    Twenty sets of relevant Nondestructive Evaluation (NDE) reliability data have been identified, collected, compiled, and categorized. A criterion for the selection of data for statistical analysis considerations has been formulated. A model to grade the quality and validity of the data sets has been developed. Data input formats, which record the pertinent parameters of the defect/specimen and inspection procedures, have been formulated for each NDE method. A comprehensive computer program has been written to calculate the probability of flaw detection at several confidence levels by the binomial distribution. This program also selects the desired data sets for pooling and tests the statistical pooling criteria before calculating the composite detection reliability. Probability of detection curves at 95 and 50 percent confidence levels have been plotted for individual sets of relevant data as well as for several sets of merged data with common sets of NDE parameters.

  6. The SPADE Symptom Cluster in Primary Care Patients With Chronic Pain.

    PubMed

    Davis, Lorie L; Kroenke, Kurt; Monahan, Patrick; Kean, Jacob; Stump, Timothy E

    2016-05-01

    Sleep disturbance, pain, anxiety, depression, and low energy/fatigue, the SPADE pentad, are the most prevalent and co-occurring symptoms in the general population and clinical practice. Co-occurrence of SPADE symptoms may produce additive impairment and negatively affect treatment response, potentially undermining patients' health and functioning. The purpose of this paper is to determine: (1) prevalence and comorbidity (ie, clustering) of SPADE symptoms; (2) internal reliability and construct validity of a composite SPADE symptom score derived from the Patient-Reported Outcomes Measurement Information System (PROMIS) measures; and (3) whether improvement in somatic symptom burden represented by a composite score predicted subsequent measures of functional status at 3 and 12 months follow-up. Secondary analysis of data from the Stepped Care to Optimize Pain care Effectiveness study, a randomized trial of a collaborative care intervention for Veterans with chronic pain. Most patients had multiple SPADE symptoms; only 9.6% of patients were monosymptomatic. The composite PROMIS symptom score had good internal reliability (Cronbach's alpha=0.86) and construct validity and strongly correlated with multiple measures of functional status; improvement in the composite score significantly correlated with higher scores for 5 of 6 functional status outcomes. The standardized error of measurement (SEM) for the composite T-score was 2.84, suggesting a 3-point difference in an individual's composite score may be clinically meaningful. Brief PROMIS measures may be useful in evaluating SPADE symptoms and overall symptom burden. Because symptom burden may predict functional status outcomes, better identification and management of comorbid symptoms may be warranted.

  7. Progress on automated data analysis algorithms for ultrasonic inspection of composites

    NASA Astrophysics Data System (ADS)

    Aldrin, John C.; Forsyth, David S.; Welter, John T.

    2015-03-01

    Progress is presented on the development and demonstration of automated data analysis (ADA) software to address the burden in interpreting ultrasonic inspection data for large composite structures. The automated data analysis algorithm is presented in detail, which follows standard procedures for analyzing signals for time-of-flight indications and backwall amplitude dropout. New algorithms have been implemented to reliably identify indications in time-of-flight images near the front and back walls of composite panels. Adaptive call criteria have also been applied to address sensitivity to variation in backwall signal level, panel thickness variation, and internal signal noise. ADA processing results are presented for a variety of test specimens that include inserted materials and discontinuities produced under poor manufacturing conditions. Software tools have been developed to support both ADA algorithm design and certification, producing a statistical evaluation of indication results and false calls using a matching process with predefined truth tables. Parametric studies were performed to evaluate detection and false call results with respect to varying algorithm settings.

  8. Microtomography evaluation of dental tissue wear surface induced by in vitro simulated chewing cycles on human and composite teeth.

    PubMed

    Bedini, Rossella; Pecci, Raffaella; Notarangelo, Gianluca; Zuppante, Francesca; Persico, Salvatore; Di Carlo, Fabio

    2012-01-01

    In this study a 3D microtomography display of tooth surfaces after in vitro dental wear tests has been obtained. Natural teeth have been compared with prosthetic teeth, manufactured by three different polyceramic composite materials. The prosthetic dental element samples, similar to molars, have been placed in opposition to human teeth extracted by paradontology diseases. After microtomography analysis, samples have been subjected to in vitro fatigue test cycles by servo-hydraulic mechanical testing machine. After the fatigue test, each sample has been subjected again to microtomography analysis to obtain volumetric value changes and dental wear surface images. Wear surface images were obtained by 3D reconstruction software and volumetric value changes were measured by CT analyser software. The aim of this work has been to show the potential of microtomography technique to display very clear and reliable wear surface images. Microtomography analysis methods to evaluate volumetric value changes have been used to quantify dental tissue and composite material wear.

  9. A Critique of a Phenomenological Fiber Breakage Model for Stress Rupture of Composite Materials

    NASA Technical Reports Server (NTRS)

    Reeder, James R.

    2010-01-01

    Stress rupture is not a critical failure mode for most composite structures, but there are a few applications where it can be critical. One application where stress rupture can be a critical design issue is in Composite Overwrapped Pressure Vessels (COPV's), where the composite material is highly and uniformly loaded for long periods of time and where very high reliability is required. COPV's are normally required to be proof loaded before being put into service to insure strength, but it is feared that the proof load may cause damage that reduces the stress rupture reliability. Recently, a fiber breakage model was proposed specifically to estimate a reduced reliability due to proof loading. The fiber breakage model attempts to model physics believed to occur at the microscopic scale, but validation of the model has not occurred. In this paper, the fiber breakage model is re-derived while highlighting assumptions that were made during the derivation. Some of the assumptions are examined to assess their effect on the final predicted reliability.

  10. Development and evaluation of CAHPS survey items assessing how well healthcare providers address health literacy.

    PubMed

    Weidmer, Beverly A; Brach, Cindy; Hays, Ron D

    2012-09-01

    The complexity of health information often exceeds patients' skills to understand and use it. To develop survey items assessing how well healthcare providers communicate health information. Domains and items for the Consumer Assessment of Healthcare Providers and Systems (CAHPS) Item Set for Addressing Health Literacy were identified through an environmental scan and input from stakeholders. The draft item set was translated into Spanish and pretested in both English and Spanish. The revised item set was field tested with a randomly selected sample of adult patients from 2 sites using mail and telephonic data collection. Item-scale correlations, confirmatory factor analysis, and internal consistency reliability estimates were estimated to assess how well the survey items performed and identify composite measures. Finally, we regressed the CAHPS global rating of the provider item on the CAHPS core communication composite and the new health literacy composites. A total of 601 completed surveys were obtained (52% response rate). Two composite measures were identified: (1) Communication to Improve Health Literacy (16 items); and (2) How Well Providers Communicate About Medicines (6 items). These 2 composites were significantly uniquely associated with the global rating of the provider (communication to improve health literacy: P<0.001, b=0.28; and communication about medicines composite: P=0.02, b=0.04). The 2 composites and the CAHPS core communication composite accounted for 51% of the variance in the global rating of the provider. A 5-item subset of the Communication to Improve Health Literacy composite accounted for 90% of the variance of the original 16-item composite. This study provides support for reliability and validity of the CAHPS Item Set for Addressing Health Literacy. These items can serve to assess whether healthcare providers have communicated effectively with their patients and as a tool for quality improvement.

  11. Pile Driving

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Machine-oriented structural engineering firm TERA, Inc. is engaged in a project to evaluate the reliability of offshore pile driving prediction methods to eventually predict the best pile driving technique for each new offshore oil platform. Phase I Pile driving records of 48 offshore platforms including such information as blow counts, soil composition and pertinent construction details were digitized. In Phase II, pile driving records were statistically compared with current methods of prediction. Result was development of modular software, the CRIPS80 Software Design Analyzer System, that companies can use to evaluate other prediction procedures or other data bases.

  12. Developing and testing the CHORDS: Characteristics of Responsible Drinking Survey.

    PubMed

    Barry, Adam E; Goodson, Patricia

    2011-01-01

    Report on the development and psychometric testing of a theoretically and evidence-grounded instrument, the Characteristics of Responsible Drinking Survey (CHORDS). Instrument subjected to four phases of pretesting (cognitive validity, cognitive and motivational qualities, pilot test, and item evaluation) and a final posttest implementation. Large public university in Texas. Randomly selected convenience sample (n  =  729) of currently enrolled students. This 78-item questionnaire measures individuals' responsible drinking beliefs, motivations, intentions, and behaviors. Cronbach α, split-half reliability, principal components analysis and Spearman ρ were conducted to investigate reliability, stability, and validity. Measures in the CHORDS exhibited high internal consistency reliability and strong correlations of split-half reliability. Factor analyses indicated five distinct scales were present, as proposed in the theoretical model. Subscale composite scores also exhibited a correlation to alcohol consumption behaviors, indicating concurrent validity. The CHORDS represents the first instrument specifically designed to assess responsible drinking beliefs and behaviors. It was found to elicit valid and reliable data among a college student sample. This instrument holds much promise for practitioners who desire to empirically investigate dimensions of responsible drinking.

  13. Psychometric evaluation of a unified Portuguese-language version of the Body Shape Questionnaire in female university students.

    PubMed

    Silva, Wanderson Roberto; Costa, David; Pimenta, Filipa; Maroco, João; Campos, Juliana Alvares Duarte Bonini

    2016-07-21

    The objectives of this study were to develop a unified Portuguese-language version, for use in Brazil and Portugal, of the Body Shape Questionnaire (BSQ) and to estimate its validity, reliability, and internal consistency in Brazilian and Portuguese female university students. Confirmatory factor analysis was performed using both original (34-item) and shortened (8-item) versions. The model's fit was assessed with χ²/df, CFI, NFI, and RMSEA. Concurrent and convergent validity were assessed. Reliability was estimated through internal consistency and composite reliability (α). Transnational invariance of the BSQ was tested using multi-group analysis. The original 32-item model was refined to present a better fit and adequate validity and reliability. The shortened model was stable in both independent samples and in transnational samples (Brazil and Portugal). The use of this unified version is recommended for the assessment of body shape concerns in both Brazilian and Portuguese college students.

  14. Effect of Processing Parameters on Reliability of VARTM/SCRIMP Composite Panels - Phase 1

    DTIC Science & Technology

    2007-07-01

    used in this program (Hess and Beach, 2000). The structural risks associated with new FRP composite ship structures can be mitigated by...reliability calibration of new designs. This program focuses on addressing the first and second tasks outlined above. 1.2. Phase I - Objectives The...Accomplishments: Tension Testing An optimized geometry for tension coupon testing was developed for marine grade composites. The new geometry reduces

  15. Composite Stress Rupture: A New Reliability Model Based on Strength Decay

    NASA Technical Reports Server (NTRS)

    Reeder, James R.

    2012-01-01

    A model is proposed to estimate reliability for stress rupture of composite overwrap pressure vessels (COPVs) and similar composite structures. This new reliability model is generated by assuming a strength degradation (or decay) over time. The model suggests that most of the strength decay occurs late in life. The strength decay model will be shown to predict a response similar to that predicted by a traditional reliability model for stress rupture based on tests at a single stress level. In addition, the model predicts that even though there is strength decay due to proof loading, a significant overall increase in reliability is gained by eliminating any weak vessels, which would fail early. The model predicts that there should be significant periods of safe life following proof loading, because time is required for the strength to decay from the proof stress level to the subsequent loading level. Suggestions for testing the strength decay reliability model have been made. If the strength decay reliability model predictions are shown through testing to be accurate, COPVs may be designed to carry a higher level of stress than is currently allowed, which will enable the production of lighter structures

  16. FEAMAC/CARES Stochastic-Strength-Based Damage Simulation Tool for Ceramic Matrix Composites

    NASA Technical Reports Server (NTRS)

    Nemeth, Noel; Bednarcyk, Brett; Pineda, Evan; Arnold, Steven; Mital, Subodh; Murthy, Pappu; Bhatt, Ramakrishna

    2016-01-01

    Reported here is a coupling of two NASA developed codes: CARES (Ceramics Analysis and Reliability Evaluation of Structures) with the MAC/GMC (Micromechanics Analysis Code/ Generalized Method of Cells) composite material analysis code. The resulting code is called FEAMAC/CARES and is constructed as an Abaqus finite element analysis UMAT (user defined material). Here we describe the FEAMAC/CARES code and an example problem (taken from the open literature) of a laminated CMC in off-axis loading is shown. FEAMAC/CARES performs stochastic-strength-based damage simulation response of a CMC under multiaxial loading using elastic stiffness reduction of the failed elements.

  17. Stochastic-Strength-Based Damage Simulation Tool for Ceramic Matrix Composite

    NASA Technical Reports Server (NTRS)

    Nemeth, Noel; Bednarcyk, Brett; Pineda, Evan; Arnold, Steven; Mital, Subodh; Murthy, Pappu

    2015-01-01

    Reported here is a coupling of two NASA developed codes: CARES (Ceramics Analysis and Reliability Evaluation of Structures) with the MAC/GMC (Micromechanics Analysis Code/ Generalized Method of Cells) composite material analysis code. The resulting code is called FEAMAC/CARES and is constructed as an Abaqus finite element analysis UMAT (user defined material). Here we describe the FEAMAC/CARES code and an example problem (taken from the open literature) of a laminated CMC in off-axis loading is shown. FEAMAC/CARES performs stochastic-strength-based damage simulation response of a CMC under multiaxial loading using elastic stiffness reduction of the failed elements.

  18. Validity and reliability of the Self-Reported Physical Fitness (SRFit) survey.

    PubMed

    Keith, NiCole R; Clark, Daniel O; Stump, Timothy E; Miller, Douglas K; Callahan, Christopher M

    2014-05-01

    An accurate physical fitness survey could be useful in research and clinical care. To estimate the validity and reliability of a Self-Reported Fitness (SRFit) survey; an instrument that estimates muscular fitness, flexibility, cardiovascular endurance, BMI, and body composition (BC) in adults ≥ 40 years of age. 201 participants completed the SF-36 Physical Function Subscale, International Physical Activity Questionnaire (IPAQ), Older Adults' Desire for Physical Competence Scale (Rejeski), the SRFit survey, and the Rikli and Jones Senior Fitness Test. BC, height and weight were measured. SRFit survey items described BC, BMI, and Senior Fitness Test movements. Correlations between the Senior Fitness Test and the SRFit survey assessed concurrent validity. Cronbach's Alpha measured internal consistency within each SRFit domain. SRFit domain scores were compared with SF-36, IPAQ, and Rejeski survey scores to assess construct validity. Intraclass correlations evaluated test-retest reliability. Correlations between SRFit and the Senior Fitness Test domains ranged from 0.35 to 0.79. Cronbach's Alpha scores were .75 to .85. Correlations between SRFit and other survey scores were -0.23 to 0.72 and in the expected direction. Intraclass correlation coefficients were 0.79 to 0.93. All P-values were 0.001. Initial evaluation supports the SRFit survey's validity and reliability.

  19. Reliable change, sensitivity, and specificity of a multidimensional concussion assessment battery: implications for caution in clinical practice.

    PubMed

    Register-Mihalik, Johna K; Guskiewicz, Kevin M; Mihalik, Jason P; Schmidt, Julianne D; Kerr, Zachary Y; McCrea, Michael A

    2013-01-01

    To provide reliable change confidence intervals for common clinical concussion measures using a healthy sample of collegiate athletes and to apply these reliable change parameters to a sample of concussed collegiate athletes. Two independent samples were included in the study and evaluated on common clinical measures of concussion. The healthy sample included male, collegiate football student-athletes (n = 38) assessed at 2 time points. The concussed sample included college-aged student-athletes (n = 132) evaluated before and after a concussion. Outcome measures included symptom severity scores, Automated Neuropsychological Assessment Metrics throughput scores, and Sensory Organization Test composite scores. Application of the reliable change parameters suggests that a small percentage of concussed participants were impaired on each measure. We identified a low sensitivity of the entire battery (all measures combined) of 50% but high specificity of 96%. Clinicians should be trained in understanding clinical concussion measures and should be aware of evidence suggesting the multifaceted battery is more sensitive than any single measure. Clinicians should be cautioned that sensitivity to balance and neurocognitive impairments was low for each individual measure. Applying the confidence intervals to our injured sample suggests that these measures do not adequately identify postconcussion impairments when used in isolation.

  20. Acoustic emission from composite materials. [nondestructive tests

    NASA Technical Reports Server (NTRS)

    Visconti, I. C.; Teti, R.

    1979-01-01

    The two basic areas where the acoustic emission (AE) technique can be applied are materials research and the evaluation of structural reliability. This experimental method leads to a better understanding of fracture mechanisms and is an NDT technique particularly well suited for the study of propagating cracks. Experiments are described in which acoustic emissions were unambiguously correlated with microstructural fracture mechanisms. The advantages and limitations of the AE technique are noted.

  1. Evaluating the test-retest reliability of symptom indices associated with the ImPACT post-concussion symptom scale (PCSS).

    PubMed

    Merritt, Victoria C; Bradson, Megan L; Meyer, Jessica E; Arnett, Peter A

    2018-05-01

    The Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) is a commonly used tool in sports concussion assessment. While test-retest reliabilities have been established for the ImPACT cognitive composites, few studies have evaluated the psychometric properties of the ImPACT's Post-Concussion Symptom Scale (PCSS). The purpose of this study was to establish the test-retest reliability of symptom indices associated with the PCSS. Participants included 38 undergraduate students (50.0% male) who underwent neuropsychological testing as part of their participation in their psychology department's research subject pool. The majority of the participants were Caucasian (94.7%) and had no history of concussion (73.7%). All participants completed the ImPACT at two time points, approximately 6 weeks apart. The PCSS was the main outcome measure, and eight symptom indices were calculated (a total symptom score, three symptom summary indices, and four symptom clusters). Pearson correlations (r) and intraclass correlation coefficients (ICCs) were computed as measures of test-retest reliability. Overall, reliabilities ranged from low to high (r = .44 to .80; ICC = .44 to .77). The cognitive symptom cluster exhibited the highest test-retest reliability (r = .80, ICC = .77), followed by the positive symptom total (PST) index, an indicator of the total number of symptoms endorsed (r = .71, ICC = .69). In contrast, the commonly used total symptom score showed lower test-retest reliability (r = .67, ICC = .62). Paired-samples t tests revealed no significant differences between test and retest for any of the symptom variables (all p > .01). Finally, reliable change indices (RCI) were computed to determine whether differences observed between test and retest represented clinically significant change. RCI values were provided for each symptom index at the 80%, 90%, and 95% confidence intervals. These results suggest that evaluating additional symptom indices beyond the total symptom score from the PCSS is beneficial. Findings from this study can be applied to athlete samples to assess reliable change in symptoms following concussion.

  2. Critical Needs for Robust and Reliable Database for Design and Manufacturing of Ceramic Matrix Composites

    NASA Technical Reports Server (NTRS)

    Singh, M.

    1999-01-01

    Ceramic matrix composite (CMC) components are being designed, fabricated, and tested for a number of high temperature, high performance applications in aerospace and ground based systems. The critical need for and the role of reliable and robust databases for the design and manufacturing of ceramic matrix composites are presented. A number of issues related to engineering design, manufacturing technologies, joining, and attachment technologies, are also discussed. Examples of various ongoing activities in the area of composite databases. designing to codes and standards, and design for manufacturing are given.

  3. Probabilistic Analysis of a Composite Crew Module

    NASA Technical Reports Server (NTRS)

    Mason, Brian H.; Krishnamurthy, Thiagarajan

    2011-01-01

    An approach for conducting reliability-based analysis (RBA) of a Composite Crew Module (CCM) is presented. The goal is to identify and quantify the benefits of probabilistic design methods for the CCM and future space vehicles. The coarse finite element model from a previous NASA Engineering and Safety Center (NESC) project is used as the baseline deterministic analysis model to evaluate the performance of the CCM using a strength-based failure index. The first step in the probabilistic analysis process is the determination of the uncertainty distributions for key parameters in the model. Analytical data from water landing simulations are used to develop an uncertainty distribution, but such data were unavailable for other load cases. The uncertainty distributions for the other load scale factors and the strength allowables are generated based on assumed coefficients of variation. Probability of first-ply failure is estimated using three methods: the first order reliability method (FORM), Monte Carlo simulation, and conditional sampling. Results for the three methods were consistent. The reliability is shown to be driven by first ply failure in one region of the CCM at the high altitude abort load set. The final predicted probability of failure is on the order of 10-11 due to the conservative nature of the factors of safety on the deterministic loads.

  4. Low concentration graphene nanoplatelets for shape stabilization and thermal transfer reinforcement of Mannitol: a phase change material for a medium-temperature thermal energy system

    NASA Astrophysics Data System (ADS)

    Jing, Gu; Dehong, Xia; Li, Wang; Wenqing, Ao; Zhaodong, Qi

    2018-03-01

    We report herein a novel series of Mannitol/GNPs (graphene nanoplatelets) composites with incremental GNPs loadings from 1 wt% to 10 wt% for further applications in medium-temperature thermal energy system. The phase change behavior and thermal conductivity of Mannitol/GNPs composite, a nanostructured PCM, have been evaluated as a function of GNPs content. Compared to the pristine Mannitol, the resultant stabilized composite with 8 wt% of GNPs displays an extremely high 1054% enhancement in thermal conductivity, and inherits 92% of phase change enthalpy of bulk Mannitol PCM (phase change material). More importantly, 92%Mannitol/GNPs composite still preserves its initial shape without any leakage even when subjected to a 400 consecutive melting/re-solidification cycles. The resulting Mannitol composites exhibit excellent chemical compatibility, large phase change enthalpy and improved thermal reliability, as compared to base PCM, which stands distinct in its class of organic with reference to the past literatures.

  5. Outer skin protection of columbium Thermal Protection System (TPS) panels

    NASA Technical Reports Server (NTRS)

    Culp, J. D.

    1973-01-01

    A coated columbium alloy material system 0.04 centimeter thick was developed which provides for increased reliability to the load bearing character of the system in the event of physical damage to and loss of the exterior protective coating. The increased reliability to the load bearing columbium alloy (FS-85) was achieved by interposing an oxidation resistant columbium alloy (B-1) between the FS-85 alloy and a fused slurry silicide coating. The B-1 alloy was applied as a cladding to the FS-85 and the composite was fused slurry silicide coated. Results of material evaluation testing included cyclic oxidation testing of specimens with intentional coating defects, tensile testing of several material combinations exposed to reentry profile conditions, and emittance testing after cycling of up to 100 simulated reentries. The clad material, which was shown to provide greater reliability than unclad materials, holds significant promise for use in the thermal protection system of hypersonic reentry vehicles.

  6. Evaluation of the Consumer Assessment of Healthcare Providers and Systems In-Center Hemodialysis Survey

    PubMed Central

    Paoli, Carly J.; Hays, Ron D.; Taylor-Stokes, Gavin; Piercy, James; Gitlin, Matthew

    2014-01-01

    Background and objectives The US Centers for Medicare and Medicaid Services (CMS) End Stage Renal Disease Prospective Payment System and Quality Incentive Program requires that dialysis centers meet predefined criteria for quality of patient care to ensure future funding. The CMS selected the Consumer Assessment of Healthcare Providers and Systems In-Center Hemodialysis (CAHPS-ICH) survey for the assessment of patient experience of care. This analysis evaluated the psychometric properties of the CAHPS-ICH survey in a sample of hemodialysis patients. Design, setting, participants, & measurements Data were drawn from the Adelphi CKD Disease Specific Program (a retrospective, cross-sectional survey of nephrologists and patients). Selected United States–based nephrologists treating patients receiving hemodialysis completed patient record forms and provided information on their dialysis center. Patients (n=404) completed the CAHPS-ICH survey (comprising 58 questions) providing six scores for the assessment of patient experience of care. CAHPS-ICH item-scale convergence, discrimination, and reliability were evaluated for multi-item scales. Floor and ceiling effects were estimated for all six scores. Patient (demographics, dialysis history, vascular access method) and facility characteristics (size, ratio of patients-to-physicians, nurses, and technicians) associated with the CAHPS-ICH scores were also evaluated. Results Item-scale correlations and internal consistency reliability estimates provided support for the nephrologists’ communication (range, 0.16–0.71; α=0.81) and quality of care (range, 0.16–0.76; α=0.90) composites. However, the patient information composite had low internal consistency reliability (α=0.55). Provider-to-patient ratios (range, 2.37 for facilities with >36 patients per physician to 2.8 for those with <8 patients per physician) and time spent in the waiting room (3.44 for >15 minutes of waiting time to 3.75 for 5 to <10 minutes) were characteristics most consistently related to patients’ perceptions of dialysis care. Conclusions CAHPS-ICH is a potentially valuable and informative tool for the evaluation of patients’ experiences with dialysis care. Additional studies are needed to estimate clinically meaningful differences between care providers. PMID:24832092

  7. Shear bond strength of indirect composite material to monolithic zirconia

    PubMed Central

    2016-01-01

    PURPOSE This study aimed to evaluate the effect of surface treatments on bond strength of indirect composite material (Tescera Indirect Composite System) to monolithic zirconia (inCoris TZI). MATERIALS AND METHODS Partially stabilized monolithic zirconia blocks were cut into with 2.0 mm thickness. Sintered zirconia specimens were divided into different surface treatment groups: no treatment (control), sandblasting, glaze layer & hydrofluoric acid application, and sandblasting + glaze layer & hydrofluoric acid application. The indirect composite material was applied to the surface of the monolithic zirconia specimens. Shear bond strength value of each specimen was evaluated after thermocycling. The fractured surface of each specimen was examined with a stereomicroscope and a scanning electron microscope to assess the failure types. The data were analyzed using one-way analysis of variance (ANOVA) and Tukey LSD tests (α=.05). RESULTS Bond strength was significantly lower in untreated specimens than in sandblasted specimens (P<.05). No difference between the glaze layer and hydrofluoric acid application treated groups were observed. However, bond strength for these groups were significantly higher as compared with the other two groups (P<.05). CONCLUSION Combined use of glaze layer & hydrofluoric acid application and silanization are reliable for strong and durable bonding between indirect composite material and monolithic zirconia. PMID:27555895

  8. Asymmetrical flow field-flow fractionation of white wine chromophoric colloidal matter.

    PubMed

    Coelho, Christian; Parot, Jérémie; Gonsior, Michael; Nikolantonaki, Maria; Schmitt-Kopplin, Philippe; Parlanti, Edith; Gougeon, Régis D

    2017-04-01

    Two analytical separation methods-size-exclusion chromatography and asymmetrical flow field-flow fractionation-were implemented to evaluate the integrity of the colloidal composition of Chardonnay white wine and the impact of pressing and fermentations on the final macromolecular composition. Wine chromophoric colloidal matter, representing UV-visible-absorbing wine macromolecules, was evaluated by optical and structural measurements combined with the description of elution profiles obtained by both separative techniques. The objective of this study was to apply these two types of fractionation on a typical Chardonnay white wine produced in Burgundy and to evaluate how each of them impacted the determination of the macromolecular chromophoric content of wine. UV-visible and fluorescence measurements of collected fractions were successfully applied. An additional proteomic study revealed that grape and microorganism proteins largely impacted the composition of chromophoric colloidal matter of Chardonnay wines. Asymmetrical flow field-flow fractionation appeared to be more reliable and less invasive with respect to the native chemical environment of chromophoric wine macromolecules, and hence is recommended as a tool to fractionate chromophoric colloidal matter in white wines. Graphical Abstract An innovative macromolecular separation method based on Asymmetrical Flow Field-Flow Fractionation was developed to better control colloidal dynamics across Chardonnay white winemaking.

  9. "Reliability generalization of the Multigroup Ethnic Identity Measure-Revised (MEIM-R)": Correction to Herrington et al. (2016).

    PubMed

    2016-10-01

    Reports an error in "Reliability Generalization of the Multigroup Ethnic Identity Measure-Revised (MEIM-R)" by Hayley M. Herrington, Timothy B. Smith, Erika Feinauer and Derek Griner ( Journal of Counseling Psychology , Advanced Online Publication, Mar 17, 2016, np). The name of author Erika Feinauer was misspelled as Erika Feinhauer. All versions of this article have been corrected. (The following abstract of the original article appeared in record 2016-13160-001.) Individuals' strength of ethnic identity has been linked with multiple positive indicators, including academic achievement and overall psychological well-being. The measure researchers use most often to assess ethnic identity, the Multigroup Ethnic Identity Measure (MEIM), underwent substantial revision in 2007. To inform scholars investigating ethnic identity, we performed a reliability generalization analysis on data from the revised version (MEIM-R) and compared it with data from the original MEIM. Random-effects weighted models evaluated internal consistency coefficients (Cronbach's alpha). Reliability coefficients for the MEIM-R averaged α = .88 across 37 samples, a statistically significant increase over the average of α = .84 for the MEIM across 75 studies. Reliability coefficients for the MEIM-R did not differ across study and participant characteristics such as sample gender and ethnic composition. However, consistently lower reliability coefficients averaging α = .81 were found among participants with low levels of education, suggesting that greater attention to data reliability is warranted when evaluating the ethnic identity of individuals such as middle-school students. Future research will be needed to ascertain whether data with other measures of aspects of personal identity (e.g., racial identity, gender identity) also differ as a function of participant level of education and associated cognitive or maturation processes. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  10. Reliability generalization of the Multigroup Ethnic Identity Measure-Revised (MEIM-R).

    PubMed

    Herrington, Hayley M; Smith, Timothy B; Feinauer, Erika; Griner, Derek

    2016-10-01

    [Correction Notice: An Erratum for this article was reported in Vol 63(5) of Journal of Counseling Psychology (see record 2016-33161-001). The name of author Erika Feinauer was misspelled as Erika Feinhauer. All versions of this article have been corrected.] Individuals' strength of ethnic identity has been linked with multiple positive indicators, including academic achievement and overall psychological well-being. The measure researchers use most often to assess ethnic identity, the Multigroup Ethnic Identity Measure (MEIM), underwent substantial revision in 2007. To inform scholars investigating ethnic identity, we performed a reliability generalization analysis on data from the revised version (MEIM-R) and compared it with data from the original MEIM. Random-effects weighted models evaluated internal consistency coefficients (Cronbach's alpha). Reliability coefficients for the MEIM-R averaged α = .88 across 37 samples, a statistically significant increase over the average of α = .84 for the MEIM across 75 studies. Reliability coefficients for the MEIM-R did not differ across study and participant characteristics such as sample gender and ethnic composition. However, consistently lower reliability coefficients averaging α = .81 were found among participants with low levels of education, suggesting that greater attention to data reliability is warranted when evaluating the ethnic identity of individuals such as middle-school students. Future research will be needed to ascertain whether data with other measures of aspects of personal identity (e.g., racial identity, gender identity) also differ as a function of participant level of education and associated cognitive or maturation processes. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  11. Coupled Multi-Disciplinary Optimization for Structural Reliability and Affordability

    NASA Technical Reports Server (NTRS)

    Abumeri, Galib H.; Chamis, Christos C.

    2003-01-01

    A computational simulation method is presented for Non-Deterministic Multidisciplinary Optimization of engine composite materials and structures. A hypothetical engine duct made with ceramic matrix composites (CMC) is evaluated probabilistically in the presence of combined thermo-mechanical loading. The structure is tailored by quantifying the uncertainties in all relevant design variables such as fabrication, material, and loading parameters. The probabilistic sensitivities are used to select critical design variables for optimization. In this paper, two approaches for non-deterministic optimization are presented. The non-deterministic minimization of combined failure stress criterion is carried out by: (1) performing probabilistic evaluation first and then optimization and (2) performing optimization first and then probabilistic evaluation. The first approach shows that the optimization feasible region can be bounded by a set of prescribed probability limits and that the optimization follows the cumulative distribution function between those limits. The second approach shows that the optimization feasible region is bounded by 0.50 and 0.999 probabilities.

  12. Multiple-foil microabrasion package (A0023)

    NASA Technical Reports Server (NTRS)

    Mcdonnell, J. A. M.; Ashworth, D. G.; Carey, W. C.; Flavill, R. P.; Jennison, R. C.

    1984-01-01

    The specific scientific objectives of this experiment are to measure the spatial distribution, size, velocity, radiance, and composition of microparticles in near-Earth space. The technological objectives are to measure erosion rates resulting from microparticle impacts and to evaluate thin-foil meteor 'bumpers'. The combinations of sensitivity and reliability in this experiment will provide up to 1000 impacts per month for laboratory analysis and will extend current sensitivity limits by 5 orders of magnitude in mass.

  13. Reliability of magnetic resonance imaging assessment of rotator cuff: the ROW study.

    PubMed

    Jain, Nitin B; Collins, Jamie; Newman, Joel S; Katz, Jeffrey N; Losina, Elena; Higgins, Laurence D

    2015-03-01

    Physiatrists encounter patients with rotator cuff disorders, and imaging is frequently an important component of their diagnostic assessment. However, there is a paucity of literature on the reliability of magnetic resonance imaging (MRI) assessment between shoulder specialists and musculoskeletal radiologists. We assessed inter- and intrarater reliability of MRI characteristics of the rotator cuff. Cross-sectional secondary analyses in a prospective cohort study. Academic tertiary care centers. Subjects with shoulder pain were recruited from orthopedic and physiatry clinics. Two shoulder-fellowship-trained physicians (a physiatrist and a shoulder surgeon) jointly performed a blinded composite MRI review by consensus of 31 subjects with shoulder pain. Subsequently, MRI was reviewed by one fellowship-trained musculoskeletal radiologist. We calculated the Cohen kappa coefficients and percentage agreement among the 2 reviews (composite review of 2 shoulder specialists versus that of the musculoskeletal radiologist). Intrarater reliability was assessed among the shoulder specialists by performing a repeated blinded composite MRI review. In addition to this repeated composite review, only one of the physiatry shoulder specialists performed an additional review. Interrater reliability (shoulder specialists versus musculoskeletal radiologist) was substantial for the presence or absence of tear (kappa 0.90 [95% confidence interval {CI}, 0.72-1.00]), tear thickness (kappa 0.84 [95% CI, 0.70-0.99]), longitudinal size of tear (kappa 0.75 [95% CI, 0.44-1.00]), fatty infiltration (kappa 0.62 [95% CI, 0.45-0.79]), and muscle atrophy (kappa 0.68 [95% CI, 0.50-0.86]). There was only fair interrater reliability of the transverse size of tear (kappa 0.20 [95% CI, 0.00-0.51]). The kappa for intrarater reliability was high for tear thickness (0.88 [95% CI, 0.72-1.00]), longitudinal tear size (0.61 [95% CI, 0.22-0.99]), fatty infiltration (0.89 [95% CI, 0.80,-0.98]), and muscle atrophy (0.87 [95% CI, 0.76-0.98]). Intrarater reliability for the individual shoulder specialist was similar to that of the composite reviews. There was high interrater and intrarater reliability for most findings on shoulder MRI. Analysis of our data supports the reliability of MRI assessment by shoulder specialists for rotator cuff disorders. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  14. Criteria for optimizing food composition tables in relation to studies of habitual food intakes.

    PubMed

    Joyanes, María; Lema, Lourdes

    2006-01-01

    The purpose of this study is to increase the accuracy, reliability, and precision of food composition data and, in consequence, better approximate nutrient intake estimations and recommendations. To do this it is necessary to specify and taken into account factors that play an important role in the variation of composition in order to avoid excessively broad dispersions and irregularities in data distributions. This implies the presentation of representative and, as consequence, extrapolable data, with nutritionally grounded confidence intervals. This study suggests a methodology that better approaches the accuracy, reliability, and precision of food composition data.

  15. The Society of Thoracic Surgeons Composite Measure of Individual Surgeon Performance for Adult Cardiac Surgery: A Report of The Society of Thoracic Surgeons Quality Measurement Task Force.

    PubMed

    Shahian, David M; He, Xia; Jacobs, Jeffrey P; Kurlansky, Paul A; Badhwar, Vinay; Cleveland, Joseph C; Fazzalari, Frank L; Filardo, Giovanni; Normand, Sharon-Lise T; Furnary, Anthony P; Magee, Mitchell J; Rankin, J Scott; Welke, Karl F; Han, Jane; O'Brien, Sean M

    2015-10-01

    Previous composite performance measures of The Society of Thoracic Surgeons (STS) were estimated at the STS participant level, typically a hospital or group practice. The STS Quality Measurement Task Force has now developed a multiprocedural, multidimensional composite measure suitable for estimating the performance of individual surgeons. The development sample from the STS National Database included 621,489 isolated coronary artery bypass grafting procedures, isolated aortic valve replacement, aortic valve replacement plus coronary artery bypass grafting, mitral, or mitral plus coronary artery bypass grafting procedures performed by 2,286 surgeons between July 1, 2011, and June 30, 2014. Each surgeon's composite score combined their aggregate risk-adjusted mortality and major morbidity rates (each weighted inversely by their standard deviations) and reflected the proportion of case types they performed. Model parameters were estimated in a Bayesian framework. Composite star ratings were examined using 90%, 95%, or 98% Bayesian credible intervals. Measure reliability was estimated using various 3-year case thresholds. The final composite measure was defined as 0.81 × (1 minus risk-standardized mortality rate) + 0.19 × (1 minus risk-standardized complication rate). Risk-adjusted mortality (median, 2.3%; interquartile range, 1.7% to 3.0%), morbidity (median, 13.7%; interquartile range, 10.8% to 17.1%), and composite scores (median, 95.4%; interquartile range, 94.4% to 96.3%) varied substantially across surgeons. Using 98% Bayesian credible intervals, there were 207 1-star (lower performance) surgeons (9.1%), 1,701 2-star (as-expected performance) surgeons (74.4%), and 378 3-star (higher performance) surgeons (16.5%). With an eligibility threshold of 100 cases over 3 years, measure reliability was 0.81. The STS has developed a multiprocedural composite measure suitable for evaluating performance at the individual surgeon level. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Monitoring the fracture behavior of metal matrix composites by combined NDE methodologies

    NASA Astrophysics Data System (ADS)

    Kordatos, E. Z.; Exarchos, D. A.; Mpalaskas, A. C.; Matikas, T. E.

    2015-03-01

    Current work deals with the non-destructive evaluation (NDE) of the fatigue behavior of metal matrix composites (MMCs) materials using Infrared Thermography (IRT) and Acoustic Emission (AE). AE monitoring was employed to record a wide spectrum of cracking events enabling the characterization of the severity of fracture in relation to the applied load. IR thermography as a non-destructive, real-time and non-contact technique, allows the detection of heat waves generated by the thermo-mechanical coupling during mechanical loading of the sample. In this study an IR methodology, based on the monitoring of the intrinsically dissipated energy, was applied for the determination of the fatigue limit of A359/SiCp composites. The thermographic monitoring is in agreement with the AE results enabling the reliable monitoring of the MMCs' fatigue behavior.

  17. Constructing the "Best" Reliability Data for the Job

    NASA Technical Reports Server (NTRS)

    DeMott, D. L.; Kleinhammer, R. K.

    2014-01-01

    Modern business and technical decisions are based on the results of analyses. When considering assessments using "reliability data", the concern is how long a system will continue to operate as designed. Generally, the results are only as good as the data used. Ideally, a large set of pass/fail tests or observations to estimate the probability of failure of the item under test would produce the best data. However, this is a costly endeavor if used for every analysis and design. Developing specific data is costly and time consuming. Instead, analysts rely on available data to assess reliability. Finding data relevant to the specific use and environment for any project is difficult, if not impossible. Instead, we attempt to develop the "best" or composite analog data to support our assessments. One method used incorporates processes for reviewing existing data sources and identifying the available information based on similar equipment, then using that generic data to derive an analog composite. Dissimilarities in equipment descriptions, environment of intended use, quality and even failure modes impact the "best" data incorporated in an analog composite. Once developed, this composite analog data provides a "better" representation of the reliability of the equipment or component can be used to support early risk or reliability trade studies, or analytical models to establish the predicted reliability data points. Data that is more representative of reality and more project specific would provide more accurate analysis, and hopefully a better final decision.

  18. Constructing the Best Reliability Data for the Job

    NASA Technical Reports Server (NTRS)

    Kleinhammer, R. K.; Kahn, J. C.

    2014-01-01

    Modern business and technical decisions are based on the results of analyses. When considering assessments using "reliability data", the concern is how long a system will continue to operate as designed. Generally, the results are only as good as the data used. Ideally, a large set of pass/fail tests or observations to estimate the probability of failure of the item under test would produce the best data. However, this is a costly endeavor if used for every analysis and design. Developing specific data is costly and time consuming. Instead, analysts rely on available data to assess reliability. Finding data relevant to the specific use and environment for any project is difficult, if not impossible. Instead, we attempt to develop the "best" or composite analog data to support our assessments. One method used incorporates processes for reviewing existing data sources and identifying the available information based on similar equipment, then using that generic data to derive an analog composite. Dissimilarities in equipment descriptions, environment of intended use, quality and even failure modes impact the "best" data incorporated in an analog composite. Once developed, this composite analog data provides a "better" representation of the reliability of the equipment or component can be used to support early risk or reliability trade studies, or analytical models to establish the predicted reliability data points. Data that is more representative of reality and more project specific would provide more accurate analysis, and hopefully a better final decision.

  19. Reliability Analysis and Reliability-Based Design Optimization of Circular Composite Cylinders Under Axial Compression

    NASA Technical Reports Server (NTRS)

    Rais-Rohani, Masoud

    2001-01-01

    This report describes the preliminary results of an investigation on component reliability analysis and reliability-based design optimization of thin-walled circular composite cylinders with average diameter and average length of 15 inches. Structural reliability is based on axial buckling strength of the cylinder. Both Monte Carlo simulation and First Order Reliability Method are considered for reliability analysis with the latter incorporated into the reliability-based structural optimization problem. To improve the efficiency of reliability sensitivity analysis and design optimization solution, the buckling strength of the cylinder is estimated using a second-order response surface model. The sensitivity of the reliability index with respect to the mean and standard deviation of each random variable is calculated and compared. The reliability index is found to be extremely sensitive to the applied load and elastic modulus of the material in the fiber direction. The cylinder diameter was found to have the third highest impact on the reliability index. Also the uncertainty in the applied load, captured by examining different values for its coefficient of variation, is found to have a large influence on cylinder reliability. The optimization problem for minimum weight is solved subject to a design constraint on element reliability index. The methodology, solution procedure and optimization results are included in this report.

  20. A Comparison of Composite Reliability Estimators: Coefficient Omega Confidence Intervals in the Current Literature

    ERIC Educational Resources Information Center

    Padilla, Miguel A.; Divers, Jasmin

    2016-01-01

    Coefficient omega and alpha are both measures of the composite reliability for a set of items. Unlike coefficient alpha, coefficient omega remains unbiased with congeneric items with uncorrelated errors. Despite this ability, coefficient omega is not as widely used and cited in the literature as coefficient alpha. Reasons for coefficient omega's…

  1. Estimating the Reliability of a Test Battery Composite or a Test Score Based on Weighted Item Scoring

    ERIC Educational Resources Information Center

    Feldt, Leonard S.

    2004-01-01

    In some settings, the validity of a battery composite or a test score is enhanced by weighting some parts or items more heavily than others in the total score. This article describes methods of estimating the total score reliability coefficient when differential weights are used with items or parts.

  2. New Flexible Silicone-Based EEG Dry Sensor Material Compositions Exhibiting Improvements in Lifespan, Conductivity, and Reliability

    PubMed Central

    Yu, Yi-Hsin; Chen, Shih-Hsun; Chang, Che-Lun; Lin, Chin-Teng; Hairston, W. David; Mrozek, Randy A.

    2016-01-01

    This study investigates alternative material compositions for flexible silicone-based dry electroencephalography (EEG) electrodes to improve the performance lifespan while maintaining high-fidelity transmission of EEG signals. Electrode materials were fabricated with varying concentrations of silver-coated silica and silver flakes to evaluate their electrical, mechanical, and EEG transmission performance. Scanning electron microscope (SEM) analysis of the initial electrode development identified some weak points in the sensors’ construction, including particle pull-out and ablation of the silver coating on the silica filler. The newly-developed sensor materials achieved significant improvement in EEG measurements while maintaining the advantages of previous silicone-based electrodes, including flexibility and non-toxicity. The experimental results indicated that the proposed electrodes maintained suitable performance even after exposure to temperature fluctuations, 85% relative humidity, and enhanced corrosion conditions demonstrating improvements in the environmental stability. Fabricated flat (forehead) and acicular (hairy sites) electrodes composed of the optimum identified formulation exhibited low impedance and reliable EEG measurement; some initial human experiments demonstrate the feasibility of using these silicone-based electrodes for typical lab data collection applications. PMID:27809260

  3. New Flexible Silicone-Based EEG Dry Sensor Material Compositions Exhibiting Improvements in Lifespan, Conductivity, and Reliability.

    PubMed

    Yu, Yi-Hsin; Chen, Shih-Hsun; Chang, Che-Lun; Lin, Chin-Teng; Hairston, W David; Mrozek, Randy A

    2016-10-31

    This study investigates alternative material compositions for flexible silicone-based dry electroencephalography (EEG) electrodes to improve the performance lifespan while maintaining high-fidelity transmission of EEG signals. Electrode materials were fabricated with varying concentrations of silver-coated silica and silver flakes to evaluate their electrical, mechanical, and EEG transmission performance. Scanning electron microscope (SEM) analysis of the initial electrode development identified some weak points in the sensors' construction, including particle pull-out and ablation of the silver coating on the silica filler. The newly-developed sensor materials achieved significant improvement in EEG measurements while maintaining the advantages of previous silicone-based electrodes, including flexibility and non-toxicity. The experimental results indicated that the proposed electrodes maintained suitable performance even after exposure to temperature fluctuations, 85% relative humidity, and enhanced corrosion conditions demonstrating improvements in the environmental stability. Fabricated flat (forehead) and acicular (hairy sites) electrodes composed of the optimum identified formulation exhibited low impedance and reliable EEG measurement; some initial human experiments demonstrate the feasibility of using these silicone-based electrodes for typical lab data collection applications.

  4. Assessment of first-year post-graduate residents: usefulness of multiple tools.

    PubMed

    Yang, Ying-Ying; Lee, Fa-Yauh; Hsu, Hui-Chi; Huang, Chin-Chou; Chen, Jaw-Wen; Cheng, Hao-Min; Lee, Wen-Shin; Chuang, Chiao-Lin; Chang, Ching-Chih; Huang, Chia-Chang

    2011-12-01

    Objective Structural Clinical Examination (OSCE) usually needs a large number of stations with long test time, which usually exceeds the resources available in a medical center. We aimed to determine the reliability of a combination of Direct Observation of Procedural Skills (DOPS), Internal Medicine in-Training Examination (IM-ITE(®)) and OSCE, and to verify the correlation between the small-scale OSCE+DOPS+IM-ITE(®)-composited scores and 360-degree evaluation scores of first year post-graduate (PGY(1)) residents. Between 2007 January to 2010 January, two hundred and nine internal medicine PGY1 residents completed DOPS, IM-ITE(®) and small-scale OSCE at our hospital. Faculty members completed 12-item 360-degree evaluation for each of the PGY(1) residents regularly. The small-scale OSCE scores correlated well with the 360-degree evaluation scores (r = 0.37, p < 0.021). Interestingly, the addition of DOPS scores to small-scale OSCE scores [small-scale OSCE+DOPS-composited scores] increased it's correlation with 360-degree evaluation scores of PGY(1) residents (r = 0.72, p < 0.036). Further, combination of IM-ITE(®) score with small-scale OSCE+DOPS scores [small-scale OSCE+DOPS+IM-ITE(®)-composited scores] markedly enhanced their correlation with 360-degree evaluation scores (r = 0.85, p < 0.016). The strong correlations between 360-degree evaluation and small-scale OSCE+DOPS+IM-ITE(®)-composited scores suggested that both methods were measuring the same quality. Our results showed that the small-scale OSCE, when associated with both the DOPS and IM-ITE(®), could be an important assessment method for PGY(1) residents. Copyright © 2011. Published by Elsevier B.V.

  5. Reliability Issues and Solutions in Flexible Electronics Under Mechanical Fatigue

    NASA Astrophysics Data System (ADS)

    Yi, Seol-Min; Choi, In-Suk; Kim, Byoung-Joon; Joo, Young-Chang

    2018-07-01

    Flexible devices are of significant interest due to their potential expansion of the application of smart devices into various fields, such as energy harvesting, biological applications and consumer electronics. Due to the mechanically dynamic operations of flexible electronics, their mechanical reliability must be thoroughly investigated to understand their failure mechanisms and lifetimes. Reliability issue caused by bending fatigue, one of the typical operational limitations of flexible electronics, has been studied using various test methodologies; however, electromechanical evaluations which are essential to assess the reliability of electronic devices for flexible applications had not been investigated because the testing method was not established. By employing the in situ bending fatigue test, we has studied the failure mechanism for various conditions and parameters, such as bending strain, fatigue area, film thickness, and lateral dimensions. Moreover, various methods for improving the bending reliability have been developed based on the failure mechanism. Nanostructures such as holes, pores, wires and composites of nanoparticles and nanotubes have been suggested for better reliability. Flexible devices were also investigated to find the potential failures initiated by complex structures under bending fatigue strain. In this review, the recent advances in test methodology, mechanism studies, and practical applications are introduced. Additionally, perspectives including the future advance to stretchable electronics are discussed based on the current achievements in research.

  6. Reliability Issues and Solutions in Flexible Electronics Under Mechanical Fatigue

    NASA Astrophysics Data System (ADS)

    Yi, Seol-Min; Choi, In-Suk; Kim, Byoung-Joon; Joo, Young-Chang

    2018-03-01

    Flexible devices are of significant interest due to their potential expansion of the application of smart devices into various fields, such as energy harvesting, biological applications and consumer electronics. Due to the mechanically dynamic operations of flexible electronics, their mechanical reliability must be thoroughly investigated to understand their failure mechanisms and lifetimes. Reliability issue caused by bending fatigue, one of the typical operational limitations of flexible electronics, has been studied using various test methodologies; however, electromechanical evaluations which are essential to assess the reliability of electronic devices for flexible applications had not been investigated because the testing method was not established. By employing the in situ bending fatigue test, we has studied the failure mechanism for various conditions and parameters, such as bending strain, fatigue area, film thickness, and lateral dimensions. Moreover, various methods for improving the bending reliability have been developed based on the failure mechanism. Nanostructures such as holes, pores, wires and composites of nanoparticles and nanotubes have been suggested for better reliability. Flexible devices were also investigated to find the potential failures initiated by complex structures under bending fatigue strain. In this review, the recent advances in test methodology, mechanism studies, and practical applications are introduced. Additionally, perspectives including the future advance to stretchable electronics are discussed based on the current achievements in research.

  7. Meta-Analysis of Scale Reliability Using Latent Variable Modeling

    ERIC Educational Resources Information Center

    Raykov, Tenko; Marcoulides, George A.

    2013-01-01

    A latent variable modeling approach is outlined that can be used for meta-analysis of reliability coefficients of multicomponent measuring instruments. Important limitations of efforts to combine composite reliability findings across multiple studies are initially pointed out. A reliability synthesis procedure is discussed that is based on…

  8. Determining efficacy of monitoring devices on ceramic bond to resin composite

    PubMed Central

    Osorio, Estrella; Aguilera, Fátima S.; Osorio, Raquel; García-Godoy, Franklin; Cabrerizo-Vilchez, Miguel A.; Toledano, Manuel

    2012-01-01

    Objectives: This paper aims to assess the effectiveness of 3D nanoroughness and 2D microroughness evaluations, by their correlation with contact angle measurements and shear bond strength test, in order to evaluate the effect of two different acids conditioning on the bonding efficacy of a leucite-based glass-ceramic to a composite resin. Study Design: Ceramic (IPS Empress) blocks were treated as follows: 1) no treatment, 2) 37% phosphoric acid (H3PO4), 15 s, 3) 9% hydrofluoric acid (HF), 5 min. Micro- and nano-roughness were assessed with a profilometer and by means of an atomic force microscopy (AFM). Water contact angle (CA) measurements were determined to assess wettability of the ceramic surfaces with the asixymetric drop shape analysis contact diameter technique. Shear bond strength (SBS) was tested to a resin composite (Z100) with three different adhesive systems (Scotchbond Multipurpose Plus, Clearfil New Bond, ProBOND). Scanning electron microscopy (SEM) images were performed. Results: Nanoroughness values assessed in 50x50 μm areas were higher for the HF group, these differences were not detected by profilometric analysis. HF treatment created the nano- roughest surfaces and the smallest CA (p<0.05), producing the highest SBS to the composite resin with all tested adhesive systems (p<0.05). No differences existed between the SBS produced by the adhesive systems evaluated with any of the surface treatments tested. Conclusions: Nano-roughness obtained in a 50x50 µm scan size areas was the most reliable data to evaluate the topographical changes produced by the different acid treatments on ceramic surfaces. Key words:Dental ceramic, acid etching, bonding efficacy, resin composite, adhesive systems, contact angle, roughness. PMID:22549693

  9. Assessing inspection sensitivity as it relates to damage tolerance in composite rotor hubs

    NASA Astrophysics Data System (ADS)

    Roach, Dennis P.; Rackow, Kirk

    2001-08-01

    Increasing niche applications, growing international markets, and the emergence of advanced rotorcraft technology are expected to greatly increase the population of helicopters over the next decade. In terms of fuselage fatigue, helicopters show similar trends as fixed-wing aircraft. The highly unsteady loads experienced by rotating wings not only directly affect components in the dynamic systems but are also transferred to the fixed airframe structure. Expanded use of rotorcraft has focused attention on the use of new materials and the optimization of maintenance practices. The FAA's Airworthiness Assurance Center (AANC) at Sandia National Labs has joined with Bell Helicopter andother agencies in the rotorcraft industry to evaluate nondestructive inspection (NDI) capabilities in light of the damage tolerance of assorted rotorcraft structure components. Currently, the program's emphasis is on composite rotor hubs. The rotorcraft industry is constantly evaluating new types of lightweight composite materials that not only enhance the safety and reliability of rotor components but also improve performance and extended operating life as well. Composite rotor hubs have led to the use of bearingless rotor systems that are less complex and require less maintenance than their predecessors. The test facility described in this paper allows the structural stability and damage tolerance of composite hubs to be evaluated using realistic flight load spectrums of centrifugal force and bending loads. NDI was integrated into the life-cycle fatigue tests in order to evaluate flaw detection sensitivity simultaneously wiht residual strength and general rotor hub peformance. This paper will describe the evolving use of damage tolerance analysis (DTA) to direct and improve rotorcraft maintenance along with the related use of nondestructive inspections to manage helicopter safety. OVeralll, the data from this project will provide information to improve the producibility, inspectability, serviceability, and cost effectively of rotorcraft components.

  10. Reliability analysis of composite laminates with load sharing

    NASA Technical Reports Server (NTRS)

    Wetherhold, Robert C.; Thomas, David J.

    1991-01-01

    By viewing a composite lamina as a homogeneous solid whose directional strengths are random variables, lamina reliability under multiaxial stresses may be determined using either an interactive or a noninteractive criterion. From the reliability values for the individual laminae comprising a given laminate, Thomas and Wetherhold (1991) have proposed a method for determining bounds for the overall laminate reliability. In this paper, simple physically plausible phenomenological rules are proposed for redistribution of load after a lamina has failed within the confines of a laminate. These rules are illustrated by application to (0/ +/-15)s and (90/ +/-45/0)s graphite/epoxy laminates, and the results are compared to the previously proposed bounds.

  11. Refinement and partial validation of the UNESP-Botucatu multidimensional composite pain scale for assessing postoperative pain in horses.

    PubMed

    Taffarel, Marilda Onghero; Luna, Stelio Pacca Loureiro; de Oliveira, Flavia Augusta; Cardoso, Guilherme Schiess; Alonso, Juliana de Moura; Pantoja, Jose Carlos; Brondani, Juliana Tabarelli; Love, Emma; Taylor, Polly; White, Kate; Murrell, Joanna C

    2015-04-01

    Quantification of pain plays a vital role in the diagnosis and management of pain in animals. In order to refine and validate an acute pain scale for horses a prospective, randomized, blinded study was conducted. Twenty-four client owned adult horses were recruited and allocated to one of four following groups: anaesthesia only (GA); pre-emptive analgesia and anaesthesia (GAA,); anaesthesia, castration and postoperative analgesia (GC); or pre-emptive analgesia, anaesthesia and castration (GCA). One investigator, unaware of the treatment group, assessed all horses at time-points before and after intervention and completed the pain scale. Videos were also obtained at these time-points and were evaluated by a further four blinded evaluators who also completed the scale. The data were used to investigate the relevance, specificity, criterion validity and inter- and intra-observer reliability of each item on the pain scale, and to evaluate construct validity and responsiveness of the scale. Construct validity was demonstrated by the observed differences in scores between the groups, four hours after anaesthetic recovery and before administration of systemic analgesia in the GC group. Inter- and intra-observer reliability for the items was only satisfactory. Subsequently the pain scale was refined, based on results for relevance, specificity and total item correlation. Scale refinement and exclusion of items that did not meet predefined requirements generated a selection of relevant pain behaviours in horses. After further validation for reliability, these may be used to evaluate pain under clinical and experimental conditions.

  12. Two baselines are better than one: Improving the reliability of computerized testing in sports neuropsychology.

    PubMed

    Bruce, Jared; Echemendia, Ruben; Tangeman, Lindy; Meeuwisse, Willem; Comper, Paul; Hutchison, Michael; Aubry, Mark

    2016-01-01

    Computerized neuropsychological tests are frequently used to assist in return-to-play decisions following sports concussion. However, due to concerns about test reliability, the Centers for Disease Control and Prevention recommends yearly baseline testing. The standard practice that has developed in baseline/postinjury comparisons is to examine the difference between the most recent baseline test and postconcussion performance. Drawing from classical test theory, the present study investigated whether temporal stability could be improved by taking an alternate approach that uses the aggregate of 2 baselines to more accurately estimate baseline cognitive ability. One hundred fifteen English-speaking professional hockey players with 3 consecutive Immediate Postconcussion Assessment and Testing (ImPACT) baseline tests were extracted from a clinical program evaluation database overseen by the National Hockey League and National Hockey League Players' Association. The temporal stability of ImPACT composite scores was significantly increased by aggregating test performance during Sessions 1 and 2 to predict performance during Session 3. Using this approach, the 2-factor Memory (r = .72) and Speed (r = .79) composites of ImPACT showed acceptable long-term reliability. Using the aggregate of 2 baseline scores significantly improves temporal stability and allows for more accurate predictions of cognitive change following concussion. Clinicians are encouraged to estimate baseline abilities by taking into account all of an athlete's previous baseline scores.

  13. On the Relationship between Maximal Reliability and Maximal Validity of Linear Composites

    ERIC Educational Resources Information Center

    Penev, Spiridon; Raykov, Tenko

    2006-01-01

    A linear combination of a set of measures is often sought as an overall score summarizing subject performance. The weights in this composite can be selected to maximize its reliability or to maximize its validity, and the optimal choice of weights is in general not the same for these two optimality criteria. We explore several relationships…

  14. The Pittsburgh Sleep Quality Index: validation of the Urdu translation.

    PubMed

    Hashmi, Ali Madeeh; Khawaja, Imran Shuja; Butt, Zeeshan; Umair, Muhammad; Naqvi, Suhaib Haider; Jawad-Ul-Haq

    2014-02-01

    To translate and validate the Pittsburgh Sleep Quality Index (PSQI), a standardized self-administered questionnaire for the assessment of subjective sleep quality into the Urdu language. Validation study. Mayo Hospital, Lahore, from March to April 2012. The PSQI was translated into Urdu following standard guidelines. The final Urdu version (PSQI-U) was administered to 200 healthy volunteers comprising medical students, nursing staff and doctors. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation of component scores with global score was assessed by calculating Spearman correlation coefficient. Correlation between global PSQI-U scores at baseline with global scores for each PSQI-U and PSQI-E at 4-week interval was evaluated by calculating Spearman correlation coefficient. Moreover, scores on individual items of the scale at baseline were compared with respective scores after 4-week by t-test. One hundred and eighty five (185) participants completed the PSQI-U at baseline. The Cronbach alpha for PSQI-U was 0.56. Scores on individual components of the PSQI-U and composite scores were all highly correlated with each other (all p-values < 0.01). Composite scores for PSQI-U at baseline and PSQI-E at 4-week interval were also highly correlated with each other (Spearman correlation coefficient 0.74, p-value < 0.01) indicating good linguistic interchangeability. Composite scores for PSQI-U at baseline and at 4-week interval were positively correlated with each other (Spearman correlation coefficient 0.70, p < 0.01) indicating good test-retest reliability. The PSQI-U is a valid and reliable instrument for the assessment of sleep quality. It shows good linguistic interchangeability and test-retest reliability in comparison to the original English version when applied to individuals who speak the Urdu language. The PSQI-U can be a tool either for clinical management or research.

  15. Evaluation of a Multi-Decadal Simulation of Stratospheric Ozone by Comparison with Total Ozone Mapping Spectrometer (TOMS) Observations

    NASA Technical Reports Server (NTRS)

    Douglass, Anne R.; Stolarski, Richard S.; Steenrod, Steven; Pawson, Steven

    2003-01-01

    One key application of atmospheric chemistry and transport models is prediction of the response of ozone and other constituents to various natural and anthropogenic perturbations. These include changes in composition, such as the previous rise and recent decline in emission of man-made chlorofluorcarbons, changes in aerosol loading due to volcanic eruption, and changes in solar forcing. Comparisons of hindcast model results for the past few decades with observations are a key element of model evaluation and provide a sense of the reliability of model predictions. The 25 year data set from Total Ozone Mapping Spectrometers is a cornerstone of such model evaluation. Here we report evaluation of three-dimensional multi-decadal simulation of stratospheric composition. Meteorological fields for this off-line calculation are taken from a 50 year simulation of a general circulation model. Model fields are compared with observations from TOMS and also with observations from the Stratospheric Aerosol and Gas Experiment (SAGE), Microwave Limb Sounder (MLS), Cryogenic Limb Array Etalon Spectrometer (CLAES), and the Halogen Occultation Experiment (HALOE). This overall evaluation will emphasize the spatial, seasonal, and interannual variability of the simulation compared with observed atmospheric variability.

  16. Characterizations of mortar-degraded spinney waste composite nominated as solidifying agent for radwastes due to immersion processes

    NASA Astrophysics Data System (ADS)

    Saleh, H. M.; Eskander, S. B.

    2012-11-01

    Immobilization process of radioactive wastes is a compromise between economic and reliability factors. It involves the use of inert and cheap matrices to fix the wastes in homogenous monolithic solid forms. The characteristics of the resulting waste form were studied in various disposal options before coming to the final conclusion concerning the solidification process. A proposed mortar composite is formed from a mixture of Portland cement and sand in the weight ratio of 0.33 which by slurry of degraded spinney waste fibers at the ratio of 0.7 relative to the Portland cement. The composite was prepared at the laboratory ambient conditions (25 ± 5 °C). The temperature changes accompanying the hydration process were followed up to 96 h. At the end of 28 days, curing period, the performance of the obtained composite was evaluated under immersion circumstances imitating a flooding scenario that could happen at a disposal site. Compressive strength, porosity and mass changes were investigated under complete static immersion conditions in three different leachants, namely acetic acid, groundwater and seawater for 48 weeks. X-ray and scanning electron microscopy were used to follow and evaluate the changes that may occur for the proposed composite under flooding conditions. Based on the experimental data reached, it could be concluded that the prepared mortar composite can be nominated as a matrix for solidification/stabilization of some radwaste categories, even under the aggressive attacks of various immersion media.

  17. Damage detection in composites using nonlinear ultrasonically modulated thermography

    NASA Astrophysics Data System (ADS)

    Malfense Fierro, G.-P.; Dionysopoulos, D.; Meo, M.; Ciampa, F.

    2018-03-01

    This paper proposes a novel nonlinear ultrasonically stimulated thermography technique for a quick and reliable assessment of material damage in carbon fibre reinforced plastic (CFRP) composite materials. The proposed nondestructive evaluation (NDE) method requires narrow sweep ultrasonic excitation using contact piezoelectric transducers in order to identify dual excitation frequencies associated with the damage resonance. High-amplitude signals and higher harmonic generation are necessary conditions for an accurate identification of these two input frequencies. Dual periodic excitation using high- and low-frequency input signals was then performed in order to generate frictional heating at the crack location that was measured by an infrared (IR) camera. To validate this concept, an impact damaged CFRP composite panel was tested and the experimental results were compared with traditional flash thermography. A laser vibrometer was used to investigate the response of the material with dual frequency excitation. The proposed nonlinear ultrasonically modulated thermography successfully detected barely visible impact damage in CFRP composites. Hence, it can be considered as an alternative to traditional flash thermography and thermosonics by allowing repeatable detection of damage in composites.

  18. Fatigue methodology III; Proceedings of the AHS National Technical Specialists' Meeting on Advanced Rotorcraft Structures, Scottsdale, AZ, Oct. 3-5, 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1989-01-01

    Papers on rotorcraft and fatigue methodology are presented, covering topics such as reliability design for rotorcraft, a comparison between theory and fatigue test data on stress concentration factors, the retirement lives of rolling element bearings, hydrogen embrittlement risk analysis for high hardness steel parts, and rotating system load monitoring with minimum fixed system instrumentation. Additional topics include usage data collection to improve structural integrity of operational helicopters, usage monitory of military helicopters, improvements to the fatigue substantiation of the H-60 composite tail rotor blade, helicopter surviellance programs, and potential application of automotive fatigue technology in rotorcraft design. Also, consideration ismore » given to fatigue evaluation of C/MH-53 E main rotor damper threaded joints, SH-2F airframe fatigue test program, a ply termination concept for improving fracture and fatigue strength of composite laminates, the analysis and testing of composite panels subject to muzzle blast effects, the certification plan for an all-composite main rotor flexbeam, and the effects of stacking sequence on the flexural strength of composite beams.« less

  19. Internal and external factors affecting photosynthetic pigment composition in plants: a meta-analytical approach.

    PubMed

    Esteban, Raquel; Barrutia, Oihana; Artetxe, Unai; Fernández-Marín, Beatriz; Hernández, Antonio; García-Plazaola, José Ignacio

    2015-04-01

    Photosynthetic pigment composition has been a major study target in plant ecophysiology during the last three decades. Although more than 2000 papers have been published, a comprehensive evaluation of the responses of photosynthetic pigment composition to environmental conditions is not yet available. After an extensive survey, we compiled data from 525 papers including 809 species (subkingdom Viridiplantae) in which pigment composition was described. A meta-analysis was then conducted to assess the ranges of photosynthetic pigment content. Calculated frequency distributions of pigments were compared with those expected from the theoretical pigment composition. Responses to environmental factors were also analysed. The results revealed that lutein and xanthophyll cycle pigments (VAZ) were highly responsive to the environment, emphasizing the high phenotypic plasticity of VAZ, whereas neoxanthin was very stable. The present meta-analysis supports the existence of relatively narrow limits for pigment ratios and also supports the presence of a pool of free 'unbound' VAZ. Results from this study provide highly reliable ranges of photosynthetic pigment contents as a framework for future research on plant pigments. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.

  20. Design Protocols and Analytical Strategies that Incorporate Structural Reliability Models

    NASA Technical Reports Server (NTRS)

    Duffy, Stephen F.

    1995-01-01

    The general goal of this project is to establish design protocols that enable the engineer to analyze and predict certain types of behavior in ceramic composites. Sections of the final report addresses the following: Description of the Problem that Motivated the Technology Development, Description of the New Technology that was Developed, Unique and Novel Features of the Technology and Results/Benefits of Application (year by year accomplishments), and Utilization of New Technology in Non-Aerospace Applications. Activities for this reporting period included the development of a design analysis as part of a cooperative agreement with general Electric Aircraft Engines. The effort focused on modifying the Toughened Ceramics Analysis and Reliability Evaluation of Structures (TCARES) algorithm for use in the design of engine components fabricated from NiAl. Other activities related to the development of an ASTM standard practice for estimating Weibull parameters. The standard focuses on the evaluation and reporting of uniaxial strength data, and the estimation of probability distribution parameters for ceramics which fail in a brittle fashion.

  1. Still under the microscope: can a surgical aptitude test predict otolaryngology resident performance?

    PubMed

    Moore, Eric J; Price, Daniel L; Van Abel, Kathryn M; Carlson, Matthew L

    2015-02-01

    Application to otolaryngology-head and neck surgery residency is highly competitive, and the interview process strives to select qualified applicants with a high aptitude for the specialty. Commonly employed criteria for applicant selection have failed to show correlation with proficiency during residency training. We evaluate the correlation between the results of a surgical aptitude test administered to otolaryngology resident applicants and their performance during residency. Retrospective study at an academic otolaryngology-head and neck surgery residency program. Between 2007 and 2013, 224 resident applicants participated in a previously described surgical aptitude test administered at a microvascular surgical station. The composite score and attitudinal scores for 24 consecutive residents who matched at our institution were recorded, and their residency performance was analyzed by faculty survey on a five-point scale. The composite and attitudinal scores were analyzed for correlation with residency performance score by regression analysis. Twenty-four residents were evaluated for overall quality as a clinician by eight faculty members who were blinded to the results of surgical aptitude testing. The results of these surveys showed good inter-rater reliability. Both the overall aptitude test scores and the subset attitudinal score showed reliability in predicting performance during residency training. The goal of the residency selection process is to evaluate the candidate's potential for success in residency and beyond. The results of this study suggest that a simple-to-administer clinical skills test may have predictive value for success in residency and clinician quality. 4. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  2. Health Monitoring System for Composite Structures

    NASA Technical Reports Server (NTRS)

    Tang, S. S.; Riccardella, P. C.; Andrews, R. J.; Grady, J. E.; Mucciaradi, A. N.

    1996-01-01

    An automated system was developed to monitor the health status of composites. It uses the vibration characteristics of composites to identify a component's damage condition. The vibration responses are characterized by a set of signal features defined in the time, frequency and spatial domains. The identification of these changes in the vibration characteristics corresponding to different health conditions was performed using pattern recognition principles. This allows efficient data reduction and interpretation of vast amounts of information. Test components were manufactured from isogrid panels to evaluate performance of the monitoring system. The components were damaged by impact to simulate different health conditions. Free vibration response was induced by a tap test on the test components. The monitoring system was trained using these free vibration responses to identify three different health conditions. They are undamaged vs. damaged, damage location and damage zone size. High reliability in identifying the correct component health condition was achieved by the monitoring system.

  3. Estimation of dc transport dynamics in strongly correlated (La,Pr,Ca)MnO{sub 3} film using an insulator-metal composite model for terahertz conductivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, T. V. A.; Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531; Hattori, A. N.

    2014-07-14

    Temperature-dependent conductivities at dc and terahertz (THz) frequency region (σ{sub THz}(ω,T)) were obtained for a strongly correlated (La{sub 0.275}Pr{sub 0.35}Ca{sub 0.375})MnO{sub 3} (LPCMO) film using THz time domain spectroscopy. A composite model that describes σ{sub THz}(ω,T) for LPCMO through the insulator-metal transition (IMT) was established by incorporating Austin-Mott model characterizing the hopping of localized electrons and Drude model explaining the behavior of free electrons. This model enables us to reliably investigate the dc transport dynamics from THz conductivity measurement, i.e., simultaneously evaluate the dc conductivity and the competing composition of metal and insulator phases through the IMT, reflecting the changesmore » in microscopic conductivity of these phases.« less

  4. Clinical composite measures of disease activity and damage used to evaluate patients with systemic lupus erythematosus: A systematic literature review.

    PubMed

    Castrejón, Isabel; Rúa-Figueroa, Iñigo; Rosario, María Piedad; Carmona, Loreto

    2014-01-01

    To determine the most appropriate indices to evaluate the disease activity and damage in patients with sytemic lupus erythematosus (SLE). A systematic literature search was performed to identify validation studies of indices used to evaluate disease activity and damage. We collected information for each instrument on every aspect of validation including feasibility, reliability, validity and sensitivity to change using ad hoc forms. A total of 38 articles were included addressing the validation of 6 composite indices to evaluate disease activity (BILAG, ECLAM, SLAM, SLEDAI, LAI and SLAQ); and 3 indices to evaluate damage (SLICC/ACE-DI, LDIQ and BILD). Only the SLAQ, LIDIQ and the BILD were self-administered. Feasibility and internal consistency was only studied in 3 indices (BILAG, SLAQ and SDI) with a Cronbach's α ranging from 0.35 to 0.87. The intra-observer reliability was examined by the intraclass correlation coefficient for BILAG with a result of 0.48 (95%CI: 0,23-0,81) and using analysis of variance for SLAM-R (0,78), SLEDAI (0,33) and the LAI (0,81). The inter-observer feasibility was evaluated using the correlation coefficient for ECLAM (0,90-0,93), the SLAM (0,86) and MEX-SLEDAI (0,97-0,89). The construct validity was examined by means of convergence with other instruments, specifically with global assessment by the physician, with similar results between indices (0,48-0,75). Lastly, responsiveness was tested in all indices except LAI, SDI and LDIQ, with a standardized response mean ranging from 0.12 to 0.75. Although multiple instruments have been validated for use in SLE it was not possible to find direct evidence of which is the most appropriate. BILAG and SLEDAI, with moderate feasibility and low responsiveness, are the 2 indices with a most complete validation and more extensively used. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  5. First evidence on the validity and reliability of the Safety Organizing Scale-Nursing Home version (SOS-NH).

    PubMed

    Ausserhofer, Dietmar; Anderson, Ruth A; Colón-Emeric, Cathleen; Schwendimann, René

    2013-08-01

    The Safety Organizing Scale is a valid and reliable measure on safety behaviors and practices in hospitals. This study aimed to explore the psychometric properties of the Safety Organizing Scale-Nursing Home version (SOS-NH). In a cross-sectional analysis of staff survey data, we examined validity and reliability of the 9-item Safety SOS-NH using American Educational Research Association guidelines. This substudy of a larger trial used baseline survey data collected from staff members (n = 627) in a variety of work roles in 13 nursing homes (NHs) in North Carolina and Virginia. Psychometric evaluation of the SOS-NH revealed good response patterns with low average of missing values across all items (3.05%). Analyses of the SOS-NH's internal structure (eg, comparative fit indices = 0.929, standardized root mean square error of approximation = 0.045) and consistency (composite reliability = 0.94) suggested its 1-dimensionality. Significant between-facility variability, intraclass correlations, within-group agreement, and design effect confirmed appropriateness of the SOS-NH for measurement at the NH level, justifying data aggregation. The SOS-NH showed discriminate validity from one related concept: communication openness. Initial evidence regarding validity and reliability of the SOS-NH supports its utility in measuring safety behaviors and practices among a wide range of NH staff members, including those with low literacy. Further psychometric evaluation should focus on testing concurrent and criterion validity, using resident outcome measures (eg, patient fall rates). Copyright © 2013 American Medical Directors Association, Inc. All rights reserved.

  6. E-Services quality assessment framework for collaborative networks

    NASA Astrophysics Data System (ADS)

    Stegaru, Georgiana; Danila, Cristian; Sacala, Ioan Stefan; Moisescu, Mihnea; Mihai Stanescu, Aurelian

    2015-08-01

    In a globalised networked economy, collaborative networks (CNs) are formed to take advantage of new business opportunities. Collaboration involves shared resources and capabilities, such as e-Services that can be dynamically composed to automate CN participants' business processes. Quality is essential for the success of business process automation. Current approaches mostly focus on quality of service (QoS)-based service selection and ranking algorithms, overlooking the process of service composition which requires interoperable, adaptable and secure e-Services to ensure seamless collaboration, data confidentiality and integrity. Lack of assessment of these quality attributes can result in e-Service composition failure. The quality of e-Service composition relies on the quality of each e-Service and on the quality of the composition process. Therefore, there is the need for a framework that addresses quality from both views: product and process. We propose a quality of e-Service composition (QoESC) framework for quality assessment of e-Service composition for CNs which comprises of a quality model for e-Service evaluation and guidelines for quality of e-Service composition process. We implemented a prototype considering a simplified telemedicine use case which involves a CN in e-Healthcare domain. To validate the proposed quality-driven framework, we analysed service composition reliability with and without using the proposed framework.

  7. Design Optimization Method for Composite Components Based on Moment Reliability-Sensitivity Criteria

    NASA Astrophysics Data System (ADS)

    Sun, Zhigang; Wang, Changxi; Niu, Xuming; Song, Yingdong

    2017-08-01

    In this paper, a Reliability-Sensitivity Based Design Optimization (RSBDO) methodology for the design of the ceramic matrix composites (CMCs) components has been proposed. A practical and efficient method for reliability analysis and sensitivity analysis of complex components with arbitrary distribution parameters are investigated by using the perturbation method, the respond surface method, the Edgeworth series and the sensitivity analysis approach. The RSBDO methodology is then established by incorporating sensitivity calculation model into RBDO methodology. Finally, the proposed RSBDO methodology is applied to the design of the CMCs components. By comparing with Monte Carlo simulation, the numerical results demonstrate that the proposed methodology provides an accurate, convergent and computationally efficient method for reliability-analysis based finite element modeling engineering practice.

  8. A Systematic Review of the Psychometric Properties of Composite LGBT Prejudice and Discrimination Scales.

    PubMed

    Morrison, Melanie A; Bishop, C J; Morrison, Todd G

    2018-01-08

    Prejudice and discrimination against LGBT individuals is widespread and has been shown to have negative consequences for sexual and gender minority persons' physical and psychological wellbeing. A recent and problematic trend in the literature is to compositely measure prejudice toward and discrimination against LGBT persons. As such, a review of the psychometric properties of scales assessing, in a combinatory fashion, negative attitudes and/or behaviors toward LGBT persons is warranted. In the current study, 32 scales were identified, and their psychometric properties were evaluated. Most of the scales reviewed did not provide sufficient information regarding item development and refinement, scale dimensionality, scale score reliability, or validity. Properties of the reviewed scales are summarized, and recommendations for better measurement practice are articulated.

  9. Composite Overwrapped Pressure Vessels (COPV) Stress Rupture Test

    NASA Technical Reports Server (NTRS)

    Russell, Richard; Flynn, Howard; Forth, Scott; Greene, Nathanael; Kezian, Michael; Varanauski, Don; Yoder, Tommy; Woodworth, Warren

    2009-01-01

    One of the major concerns for the aging Space Shuttle fleet is the stress rupture life of composite overwrapped pressure vessels (COPVs). Stress rupture life of a COPV has been defined as the minimum time during which the composite maintains structural integrity considering the combined effects of stress levels and time. To assist in the evaluation of the aging COPVs in the Orbiter fleet an analytical reliability model was developed. The actual data used to construct this model was from testing of COPVs constructed of similar, but not exactly same materials and pressure cycles as used on Orbiter vessels. Since no actual Orbiter COPV stress rupture data exists the Space Shuttle Program decided to run a stress rupture test to compare to model predictions. Due to availability of spares, the testing was unfortunately limited to one 40" vessel. The stress rupture test was performed at maximum operating pressure at an elevated temperature to accelerate aging. The test was performed in two phases. The first phase, 130 F, a moderately accelerated test designed to achieve the midpoint of the model predicted point reliability. The more aggressive second phase, performed at 160 F was designed to determine if the test article will exceed the 95% confidence interval of the model. This paper will discuss the results of this test, it's implications and possible follow-on testing.

  10. Standardization of carbon-phenolic composite test methodology

    NASA Technical Reports Server (NTRS)

    Hall, W. B.

    1986-01-01

    The objective of this study was to evaluate the residual volatiles, filler content, and resin flow test procedures for carbon-phenolic prepreg materials. The residual volatile test procedure was rewritten with tighter procedure control which was then evaluated by round robin testing by four laboratories on the same rolls of prepreg. Results indicated that the residual volatiles test was too operator and equipment dependent to be reliable, and it was recommended that the test be discontinued. The resin flow test procedures were rewritten with tighter procedure control, and it is now considered to be an acceptable test. It was recommended that the filler content determination be made prior to prepregging.

  11. The psychometric properties of a shortened Dutch version of the consequences scale used in the Core Alcohol and Drug Survey.

    PubMed

    De Bruyn, Sara; Wouters, Edwin; Ponnet, Koen; Van Damme, Joris; Van Hal, Guido

    2017-01-01

    Alcohol and drug misuse among college students has been studied extensively and has been clearly identified as a public health problem. Within more general populations alcohol misuse remains one of the leading causes of disease, disability and death worldwide. Conducting research on alcohol misuse requires valid and reliable instruments to measure its consequences. One scale that is often used is the consequences scale in the Core Alcohol and Drug Survey (CADS). However, psychometric studies on the CADS are rare and the ones that do exist report varying results. This article aims to address this imbalance by examining the psychometric properties of a Dutch version of the CADS in a large sample of Flemish university and college students. The analyses are based on data collected by the inter-university project 'Head in the clouds', measuring alcohol use among students. In total, 19,253 students participated (22.1% response rate). The CADS scale was measured using 19 consequences, and participants were asked how often they had experienced these on a 6-point scale. Firstly, the factor structure of the CADS was examined. Two models from literature were compared by performing confirmatory factor analyses (CFA) and were adapted if necessary. Secondly, we assessed the composite reliability as well as the convergent, discriminant and concurrent validity. The two-factor model, identifying personal consequences (had a hangover; got nauseated or vomited; missed a class) and social consequences (got into an argument or fight; been criticized by someone I know; done something I later regretted; been hurt or injured) was indicated to be the best model, having both a good model fit and an acceptable composite reliability. In addition, construct validity was evaluated to be acceptable, with good discriminant validity, although the convergent validity of the factor measuring 'social consequences' could be improved. Concurrent validity was evaluated as good. In deciding which model best represents the data, it is crucial that not only the model fit is evaluated, but the importance of factor reliability and validity issues is also taken into account. The two-factor model, identifying personal consequences and social consequences, was concluded to be the best model. This shortened Dutch version of the CADS (CADS_D) is a useful tool to screen alcohol-related consequences among college students.

  12. Fracture Toughness and Reliability in High-Temperature Structural Ceramics and Composites: Prospects and Challenges for the 21st Century

    NASA Technical Reports Server (NTRS)

    Dutta, Sunil

    1999-01-01

    The importance of high fracture toughness and reliability in Si3N4, and SiC-based structural ceramics and ceramic matrix composites is reviewed. The potential of these ceramics and ceramic matrix composites for high temperature applications in defense and aerospace applications such as gas turbine engines, radomes, and other energy conversion hardware have been well recognized. Numerous investigations were pursued to improve fracture toughness and reliability by incorporating various reinforcements such as particulate-, whisker-, and continuous fiber into Si3N4 and SiC matrices. All toughening mechanisms, e.g. crack deflection, crack branching, crack bridging, etc., essentially redistribute stresses at the crack tip and increase the energy needed to propagate a crack through the composite material, thereby resulting in improved fracture toughness and reliability. Because of flaw insensitivity, continuous fiber reinforced ceramic composite (CFCC) was found to have the highest potential for higher operating temperature and longer service conditions. However, the ceramic fibers should display sufficient high temperature strength and creep resistance at service temperatures above 1000 'C. The greatest challenge to date is the development of high quality ceramic fibers with associate coatings able to maintain their high strength in oxidizing environment at high temperature. In the area of processing, critical issues are, preparation of optimum matrix precursors, precursor infiltration into fiber array, and matrix densification at a temperature, where grain crystallization and fiber degradation do not occur. A broad scope of effort is required for improved processing and properties with a better understanding of all candidate composite systems.

  13. NBS: Nondestructive evaluation of nonuniformities in 2219 aluminum alloy plate: Relationship to processing

    NASA Technical Reports Server (NTRS)

    Swartzendruber, L.; Boettinger, W.; Ives, L.; Coriell, S.; Ballard, D.; Laughlin, D.; Clough, R.; Biancanieilo, F.; Blau, P.; Cahn, J.

    1980-01-01

    The compositional homogeneity, microstructure, hardness, electrical conductivity and mechanical properties of 2219 aluminum alloy plates are influenced by the process variables during casting, rolling and thermomechanical treatment. The details of these relationships wre investigated for correctly processed 2219 plate as well as for deviations caused by improper quenching after solution heat treatment. Primary emphasis was been placed on the reliability of eddy current electrical conductivity and hardness as NDE tools to detect variations in mechanical properties.

  14. Can Reliability of Multiple Component Measuring Instruments Depend on Response Option Presentation Mode?

    ERIC Educational Resources Information Center

    Menold, Natalja; Raykov, Tenko

    2016-01-01

    This article examines the possible dependency of composite reliability on presentation format of the elements of a multi-item measuring instrument. Using empirical data and a recent method for interval estimation of group differences in reliability, we demonstrate that the reliability of an instrument need not be the same when polarity of the…

  15. Validity and feasibility of the american college of surgeons colectomy composite outcome quality measure.

    PubMed

    Merkow, Ryan P; Hall, Bruce L; Cohen, Mark E; Wang, Xue; Adams, John L; Chow, Warren B; Lawson, Elise H; Bilimoria, Karl Y; Richards, Karen; Ko, Clifford Y

    2013-03-01

    To develop a reliable, robust, parsimonious, risk-adjusted 30-day composite colectomy outcome measure. A fundamental aspect in the pursuit of high-quality care is the development of valid and reliable performance measures in surgery. Colon resection is associated with appreciable morbidity and mortality and therefore is an ideal quality improvement target. From 2010 American College of Surgeons National Surgical Quality Improvement Program data, patients were identified who underwent colon resection for any indication. A composite outcome of death or any serious morbidity within 30 days of the index operation was established. A 6-predictor, parsimonious model was developed and compared with a more complex model with more variables. National caseload requirements were calculated on the basis of increasing reliability thresholds. From 255 hospitals, 22,346 patients were accrued who underwent a colon resection in 2010, most commonly for neoplasm (46.7%). A mortality or serious morbidity event occurred in 4461 patients (20.0%). At the hospital level, the median composite event rate was 20.7% (interquartile range: 15.8%-26.3%). The parsimonious model performed similarly to the full model (Akaike information criterion: 19,411 vs 18,988), and hospital-level performance comparisons were highly correlated (R = 0.97). At a reliability threshold of 0.4, 56 annual colon resections would be required and achievable at an estimated 42% of US and 69% of American College of Surgeons National Surgical Quality Improvement Program hospitals. This 42% of US hospitals performed approximately 84% of all colon resections in the country in 2008. It is feasible to design a measure with a composite outcome of death or serious morbidity after colon surgery that has a low burden for data collection, has substantial clinical importance, and has acceptable reliability.

  16. In-service health monitoring of composite structures

    NASA Technical Reports Server (NTRS)

    Pinto, Gino A.; Ventres, C. S.; Ginty, Carol A.; Chamis, Christos C.

    1990-01-01

    The aerospace industry is witnessing a vast utilization of composites in critical structural applications and anticipates even more use of them in future aircraft. Therefore, a definite need exists for a composite health monitoring expert system to meet today's current needs and tomorrow's future demands. The primary goal for this conceptual health monitoring system is functional reliably for in-service operation in the environments of various composite structures. The underlying philosophy of this system is to utilize proven vibration techniques to assess the structural integrity of a fibrous composite. Statistical methods are used to determine if the variances in the measured data are acceptable for making a reliable decision on the health status of the composite. The flexible system allows for algorithms describing any composite fatigue or damage behavior characteristic to be provided as an input to the system. Alert thresholds and variances can also be provided as an input to this system and may be updated to allow for future changes/refinements in the composite's structural integrity behavior.

  17. Modeling heterogeneous (co)variances from adjacent-SNP groups improves genomic prediction for milk protein composition traits.

    PubMed

    Gebreyesus, Grum; Lund, Mogens S; Buitenhuis, Bart; Bovenhuis, Henk; Poulsen, Nina A; Janss, Luc G

    2017-12-05

    Accurate genomic prediction requires a large reference population, which is problematic for traits that are expensive to measure. Traits related to milk protein composition are not routinely recorded due to costly procedures and are considered to be controlled by a few quantitative trait loci of large effect. The amount of variation explained may vary between regions leading to heterogeneous (co)variance patterns across the genome. Genomic prediction models that can efficiently take such heterogeneity of (co)variances into account can result in improved prediction reliability. In this study, we developed and implemented novel univariate and bivariate Bayesian prediction models, based on estimates of heterogeneous (co)variances for genome segments (BayesAS). Available data consisted of milk protein composition traits measured on cows and de-regressed proofs of total protein yield derived for bulls. Single-nucleotide polymorphisms (SNPs), from 50K SNP arrays, were grouped into non-overlapping genome segments. A segment was defined as one SNP, or a group of 50, 100, or 200 adjacent SNPs, or one chromosome, or the whole genome. Traditional univariate and bivariate genomic best linear unbiased prediction (GBLUP) models were also run for comparison. Reliabilities were calculated through a resampling strategy and using deterministic formula. BayesAS models improved prediction reliability for most of the traits compared to GBLUP models and this gain depended on segment size and genetic architecture of the traits. The gain in prediction reliability was especially marked for the protein composition traits β-CN, κ-CN and β-LG, for which prediction reliabilities were improved by 49 percentage points on average using the MT-BayesAS model with a 100-SNP segment size compared to the bivariate GBLUP. Prediction reliabilities were highest with the BayesAS model that uses a 100-SNP segment size. The bivariate versions of our BayesAS models resulted in extra gains of up to 6% in prediction reliability compared to the univariate versions. Substantial improvement in prediction reliability was possible for most of the traits related to milk protein composition using our novel BayesAS models. Grouping adjacent SNPs into segments provided enhanced information to estimate parameters and allowing the segments to have different (co)variances helped disentangle heterogeneous (co)variances across the genome.

  18. The Vanderbilt Holistic Face Processing Test: A short and reliable measure of holistic face processing

    PubMed Central

    Richler, Jennifer J.; Floyd, R. Jackie; Gauthier, Isabel

    2014-01-01

    Efforts to understand individual differences in high-level vision necessitate the development of measures that have sufficient reliability, which is generally not a concern in group studies. Holistic processing is central to research on face recognition and, more recently, to the study of individual differences in this area. However, recent work has shown that the most popular measure of holistic processing, the composite task, has low reliability. This is particularly problematic for the recent surge in interest in studying individual differences in face recognition. Here, we developed and validated a new measure of holistic face processing specifically for use in individual-differences studies. It avoids some of the pitfalls of the standard composite design and capitalizes on the idea that trial variability allows for better traction on reliability. Across four experiments, we refine this test and demonstrate its reliability. PMID:25228629

  19. The comprehensive care project: measuring physician performance in ambulatory practice.

    PubMed

    Holmboe, Eric S; Weng, Weifeng; Arnold, Gerald K; Kaplan, Sherrie H; Normand, Sharon-Lise; Greenfield, Sheldon; Hood, Sarah; Lipner, Rebecca S

    2010-12-01

    To investigate the feasibility, reliability, and validity of comprehensively assessing physician-level performance in ambulatory practice. Ambulatory-based general internists in 13 states participated in the assessment. We assessed physician-level performance, adjusted for patient factors, on 46 individual measures, an overall composite measure, and composite measures for chronic, acute, and preventive care. Between- versus within-physician variation was quantified by intraclass correlation coefficients (ICC). External validity was assessed by correlating performance on a certification exam. Medical records for 236 physicians were audited for seven chronic and four acute care conditions, and six age- and gender-appropriate preventive services. Performance on the individual and composite measures varied substantially within (range 5-86 percent compliance on 46 measures) and between physicians (ICC range 0.12-0.88). Reliabilities for the composite measures were robust: 0.88 for chronic care and 0.87 for preventive services. Higher certification exam scores were associated with better performance on the overall (r = 0.19; p<.01), chronic care (r = 0.14, p = .04), and preventive services composites (r = 0.17, p = .01). Our results suggest that reliable and valid comprehensive assessment of the quality of chronic and preventive care can be achieved by creating composite measures and by sampling feasible numbers of patients for each condition. © Health Research and Educational Trust.

  20. Probabilistic structural analysis methods of hot engine structures

    NASA Technical Reports Server (NTRS)

    Chamis, C. C.; Hopkins, D. A.

    1989-01-01

    Development of probabilistic structural analysis methods for hot engine structures at Lewis Research Center is presented. Three elements of the research program are: (1) composite load spectra methodology; (2) probabilistic structural analysis methodology; and (3) probabilistic structural analysis application. Recent progress includes: (1) quantification of the effects of uncertainties for several variables on high pressure fuel turbopump (HPFT) turbine blade temperature, pressure, and torque of the space shuttle main engine (SSME); (2) the evaluation of the cumulative distribution function for various structural response variables based on assumed uncertainties in primitive structural variables; and (3) evaluation of the failure probability. Collectively, the results demonstrate that the structural durability of hot engine structural components can be effectively evaluated in a formal probabilistic/reliability framework.

  1. Validity and reliability of the BOD POD® S/T tracking system.

    PubMed

    Tseh, W; Caputo, J L; Keefer, D J

    2010-10-01

    BOD POD(®) self-testing (S/T) body composition tracking system is a practical assessment tool designed for use in the health and fitness industries. Relative to its parent counterpart, the BOD POD(®) S/T has received little research attention. The primary purpose was to determine the validity of the BOD POD(®) S/T against hydrostatic weighing and 7-site skinfolds. Secondary aim was to determine the within-day and between-day reliability of the BOD POD(®) S/T. After a period of equipment and testing accommodation, volunteer's (N=50) body composition (%BF) via 7-site skinfolds, BOD POD(®) S/T, and hydrostatic weighing were obtained on the second and third visits. BOD POD(®) S/T significantly overestimated %BF when compared to hydrostatic weighing and 7-site skinfolds. There was no statistical difference between 7-site skinfolds and hydrostatic weighing values. BOD POD(®) S/T reliability within-day and between-days were high. While the BOD POD(®) S/T body composition tracking system is deemed reliable both within-day and between-days, it did significantly overestimate %BF in comparison to hydrostatic weighing and skinfolds. Future research should be aimed at deriving a correction factor for this body composition assessment tool. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Reliability and acceptability of the Multiple Sclerosis Quality of Life-29 questionnaire in an English-speaking cohort.

    PubMed

    Baker, Georgina; Nair, Krishnan Padmakumari Sivaraman; Baster, Kathleen; Rosato, Rosalba; Solari, Alessandra

    2018-05-01

    Multiple Sclerosis Quality-of-Life Questionnaire-54 (MSQoL-54) is a disease-specific instrument for assessing health-related quality of life (HRQoL). Due to the number of items, the time taken to complete it is long. A shorter 29-item version, Multiple Sclerosis Quality-of-Life Questionnaire-29 (MSQoL-29) is yet to be evaluated in English. To assess reliability and acceptability of English version of MSQoL-29. Among 100 participants with MS who first completed both MSQoL-54 and MSQoL-29, 91 completed MSQoL-29 after 4-8 weeks. We looked for internal consistency (Cronbach's alpha), acceptability, reliability (intraclass correlation coefficients (ICCs)) and agreement (Bland-Altman plots). ICCs were strongly positive between MSQoL-54 and MSQoL-29 (Physical Health Composite (PHC) -ICC = 0.914, confidence interval (CI) = 0.872-0.942; Mental Health Composite (MHC) - ICC = 0.875, CI = 0.814-0.916) and between the two MSQoL-29 (PHC - ICC = 0.970, CI = 0.955-0.980; MHC - ICC = 0.937, CI = 0.904-0.958). On Bland-Altman plots, the MSQoL-29 scores of 95% of participants during two visits were within the limits of agreement (LOAs). Time taken to complete MSQoL-29 was 7.2 ± 2.9 minutes and MSQoL-54 was 19.79 ± 5.4 minutes ( p = 0.0001). MSQoL-29 has good test-retest reliability in English-speaking population and was quicker to complete.

  3. Measuring the impact of diagnostic decision support on the quality of clinical decision making: development of a reliable and valid composite score.

    PubMed

    Ramnarayan, Padmanabhan; Kapoor, Ritika R; Coren, Michael; Nanduri, Vasantha; Tomlinson, Amanda L; Taylor, Paul M; Wyatt, Jeremy C; Britto, Joseph F

    2003-01-01

    Few previous studies evaluating the benefits of diagnostic decision support systems have simultaneously measured changes in diagnostic quality and clinical management prompted by use of the system. This report describes a reliable and valid scoring technique to measure the quality of clinical decision plans in an acute medical setting, where diagnostic decision support tools might prove most useful. Sets of differential diagnoses and clinical management plans generated by 71 clinicians for six simulated cases, before and after decision support from a Web-based pediatric differential diagnostic tool (ISABEL), were used. A composite quality score was calculated separately for each diagnostic and management plan by considering the appropriateness value of each component diagnostic or management suggestion, a weighted sum of individual suggestion ratings, relevance of the entire plan, and its comprehensiveness. The reliability and validity (face, concurrent, construct, and content) of these two final scores were examined. Two hundred fifty-two diagnostic and 350 management suggestions were included in the interrater reliability analysis. There was good agreement between raters (intraclass correlation coefficient, 0.79 for diagnoses, and 0.72 for management). No counterintuitive scores were demonstrated on visual inspection of the sets. Content validity was verified by a consultation process with pediatricians. Both scores discriminated adequately between the plans of consultants and medical students and correlated well with clinicians' subjective opinions of overall plan quality (Spearman rho 0.65, p < 0.01). The diagnostic and management scores for each episode showed moderate correlation (r = 0.51). The scores described can be used as key outcome measures in a larger study to fully assess the value of diagnostic decision aids, such as the ISABEL system.

  4. Development of Probabilistic Life Prediction Methodologies and Testing Strategies for MEMS and CMC's

    NASA Technical Reports Server (NTRS)

    Jadaan, Osama

    2003-01-01

    This effort is to investigate probabilistic life prediction methodologies for ceramic matrix composites and MicroElectroMechanical Systems (MEMS) and to analyze designs that determine stochastic properties of MEMS. For CMC's this includes a brief literature survey regarding lifing methodologies. Also of interest for MEMS is the design of a proper test for the Weibull size effect in thin film (bulge test) specimens. The Weibull size effect is a consequence of a stochastic strength response predicted from the Weibull distribution. Confirming that MEMS strength is controlled by the Weibull distribution will enable the development of a probabilistic design methodology for MEMS - similar to the GRC developed CARES/Life program for bulk ceramics. A main objective of this effort is to further develop and verify the ability of the Ceramics Analysis and Reliability Evaluation of Structures/Life (CARES/Life) code to predict the time-dependent reliability of MEMS structures subjected to multiple transient loads. A second set of objectives is to determine the applicability/suitability of the CARES/Life methodology for CMC analysis, what changes would be needed to the methodology and software, and if feasible, run a demonstration problem. Also important is an evaluation of CARES/Life coupled to the ANSYS Probabilistic Design System (PDS) and the potential of coupling transient reliability analysis to the ANSYS PDS.

  5. Performance of high school male athletes on the Functional Movement Screen™.

    PubMed

    Smith, Laura J; Creps, James R; Bean, Ryan; Rodda, Becky; Alsalaheen, Bara

    2017-09-01

    (1) Describe the performance of the Functional Movement Screen™ (FMS™) by reporting the proportion of adolescents with a score of ≤14 and the frequency of asymmetries in a cross-sectional sample; (2) explore associations between FMS™ to age and body mass, and explore the construct validity of the FMS™ against common postural stability measures; (3) examine the inter-rater and test-retest reliability of the FMS™ in adolescents. Cross-sectional. Field-setting. 94 male high-school athletes. The FMS™, Y-Balance Test (YBT) and Balance Error Scoring System (BESS). The median FMS™ composite score was 16 (9-21), 33% of participants scored below the suggested injury risk cutoff composite score of ≤14, and 62.8% had at least one asymmetry. No relationship was observed between the FMS™ to common static/dynamic balance tests. The inter-rater reliability of the FMS™ composite score suggested good reliability (ICC = 0.88, CI 95%:0.77, 0.94) and test-retest reliability for FMS™ composite scores was good with ICC = 0.83 (CI 95%:0.56, 0.95). FMS™ results should be interpreted cautiously with attention to the asymmetries identified during the screen, regardless of composite score. The lack of relationship between the FMS™ and other balance measures supports the notion that multiple screening tests should be used in order to provide a comprehensive picture of the adolescent athlete. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Nonlinear imaging (NIM) of barely visible impact damage (BVID) in composite panels using a semi and full air-coupled linear and nonlinear ultrasound technique

    NASA Astrophysics Data System (ADS)

    Malfense Fierro, Gian Piero; Meo, Michele

    2018-03-01

    Two non-contact methods were evaluated to address the reliability and reproducibility concerns affecting industry adoption of nonlinear ultrasound techniques for non-destructive testing and evaluation (NDT/E) purposes. A semi and a fully air-coupled linear and nonlinear ultrasound method was evaluated by testing for barely visible impact damage (BVID) in composite materials. Air coupled systems provide various advantages over contact driven systems; such as: ease of inspection, no contact and lubrication issues and a great potential for non-uniform geometry evaluation. The semi air-coupled setup used a suction attached piezoelectric transducer to excite the sample and an array of low-cost microphones to capture the signal over the inspection area, while the second method focused on a purely air-coupled setup, using an air-coupled transducer to excite the structure and capture the signal. One of the issues facing nonlinear and any air-coupled systems is transferring enough energy to stimulate wave propagation and in the case of nonlinear ultrasound; damage regions. Results for both methods provided nonlinear imaging (NIM) of damage regions using a sweep excitation methodology, with the semi aircoupled system providing clearer results.

  7. Cultural competency assessment tool for hospitals: evaluating hospitals' adherence to the culturally and linguistically appropriate services standards.

    PubMed

    Weech-Maldonado, Robert; Dreachslin, Janice L; Brown, Julie; Pradhan, Rohit; Rubin, Kelly L; Schiller, Cameron; Hays, Ron D

    2012-01-01

    The U.S. national standards for culturally and linguistically appropriate services (CLAS) in health care provide guidelines on policies and practices aimed at developing culturally competent systems of care. The Cultural Competency Assessment Tool for Hospitals (CCATH) was developed as an organizational tool to assess adherence to the CLAS standards. First, we describe the development of the CCATH and estimate the reliability and validity of the CCATH measures. Second, we discuss the managerial implications of the CCATH as an organizational tool to assess cultural competency. We pilot tested an initial draft of the CCATH, revised it based on a focus group and cognitive interviews, and then administered it in a field test with a sample of California hospitals. The reliability and validity of the CCATH were evaluated using factor analysis, analysis of variance, and Cronbach's alphas. Exploratory and confirmatory factor analyses identified 12 CCATH composites: leadership and strategic planning, data collection on inpatient population, data collection on service area, performance management systems and quality improvement, human resources practices, diversity training, community representation, availability of interpreter services, interpreter services policies, quality of interpreter services, translation of written materials, and clinical cultural competency practices. All the CCATH scales had internal consistency reliability of .65 or above, and the reliability was .70 or above for 9 of the 12 scales. Analysis of variance results showed that not-for-profit hospitals have higher CCATH scores than for-profit hospitals in five CCATH scales and higher CCATH scores than government hospitals in two CCATH scales. The CCATH showed adequate psychometric properties. Managers and policy makers can use the CCATH as a tool to evaluate hospital performance in cultural competency and identify and target improvements in hospital policies and practices that undergird the provision of CLAS.

  8. Development and validation of the Simulation Learning Effectiveness Inventory.

    PubMed

    Chen, Shiah-Lian; Huang, Tsai-Wei; Liao, I-Chen; Liu, Chienchi

    2015-10-01

    To develop and psychometrically test the Simulation Learning Effectiveness Inventory. High-fidelity simulation helps students develop clinical skills and competencies. Yet, reliable instruments measuring learning outcomes are scant. A descriptive cross-sectional survey was used to validate psychometric properties of the instrument measuring students' perception of stimulation learning effectiveness. A purposive sample of 505 nursing students who had taken simulation courses was recruited from a department of nursing of a university in central Taiwan from January 2010-June 2010. The study was conducted in two phases. In Phase I, question items were developed based on the literature review and the preliminary psychometric properties of the inventory were evaluated using exploratory factor analysis. Phase II was conducted to evaluate the reliability and validity of the finalized inventory using confirmatory factor analysis. The results of exploratory and confirmatory factor analyses revealed the instrument was composed of seven factors, named course arrangement, equipment resource, debriefing, clinical ability, problem-solving, confidence and collaboration. A further second-order analysis showed comparable fits between a three second-order factor (preparation, process and outcome) and the seven first-order factor models. Internal consistency was supported by adequate Cronbach's alphas and composite reliability. Convergent and discriminant validities were also supported by confirmatory factor analysis. The study provides evidence that the Simulation Learning Effectiveness Inventory is reliable and valid for measuring student perception of learning effectiveness. The instrument is helpful in building the evidence-based knowledge of the effect of simulation teaching on students' learning outcomes. © 2015 John Wiley & Sons Ltd.

  9. The Bereaved Parent Needs Assessment: a new instrument to assess the needs of parents whose children died in the pediatric intensive care unit*.

    PubMed

    Meert, Kathleen L; Templin, Thomas N; Michelson, Kelly N; Morrison, Wynne E; Hackbarth, Richard; Custer, Joseph R; Schim, Stephanie M; Briller, Sherylyn H; Thurston, Celia S

    2012-11-01

    To evaluate the reliability and validity of the Bereaved Parent Needs Assessment, a new instrument to measure parents' needs and need fulfillment around the time of their child's death in the pediatric intensive care unit. We hypothesized that need fulfillment would be negatively related to complicated grief and positively related to quality of life during bereavement. Cross-sectional survey. Five U.S. children's hospital pediatric intensive care units. Parents (n = 121) bereaved in a pediatric intensive care unit 6 months earlier. Surveys included the 68-item Bereaved Parent Needs Assessment, the Inventory of Complicated Grief, and the abbreviated version of the World Health Organization Quality of Life questionnaire. Each Bereaved Parent Needs Assessment item described a potential need and was rated on two scales: 1) a 5-point rating of importance (1 = not at all important, 5 = very important) and 2) a 5-point rating of fulfillment (1 = not at all met, 5 = completely met). Three composite scales were computed: 1) total importance (percentage of all needs rated ≥4 for importance), 2) total fulfillment (percentage of all needs rated ≥4 for fulfillment), and 3) percent fulfillment (percentage of important needs that were fulfilled). Internal consistency reliability was assessed by Cronbach's α and Spearman-Brown-corrected split-half reliability. Generalized estimating equations were used to test predictions between composite scales and the Inventory of Complicated Grief and World Health Organization Quality of Life questionnaire. Two items had mean importance ratings <3, and 55 had mean ratings >4. Reliability of composite scores ranged from 0.92 to 0.94. Total fulfillment was negatively correlated with Inventory of Complicated Grief (r = -.29; p < .01) and positively correlated with World Health Organization Quality of Life questionnaire (r = .21; p < .05). Percent fulfillment was also significantly correlated with both outcomes. Adjusting for parent's age, education, and loss of an only child, percent fulfillment remained significantly correlated with Inventory of Complicated Grief but not with World Health Organization Quality of Life questionnaire. The Bereaved Parent Needs Assessment demonstrated reliability and validity to assess the needs of parents bereaved in the pediatric intensive care unit. Meeting parents' needs around the time of their child's death may promote adjustment to loss.

  10. Composition of web services using Markov decision processes and dynamic programming.

    PubMed

    Uc-Cetina, Víctor; Moo-Mena, Francisco; Hernandez-Ucan, Rafael

    2015-01-01

    We propose a Markov decision process model for solving the Web service composition (WSC) problem. Iterative policy evaluation, value iteration, and policy iteration algorithms are used to experimentally validate our approach, with artificial and real data. The experimental results show the reliability of the model and the methods employed, with policy iteration being the best one in terms of the minimum number of iterations needed to estimate an optimal policy, with the highest Quality of Service attributes. Our experimental work shows how the solution of a WSC problem involving a set of 100,000 individual Web services and where a valid composition requiring the selection of 1,000 services from the available set can be computed in the worst case in less than 200 seconds, using an Intel Core i5 computer with 6 GB RAM. Moreover, a real WSC problem involving only 7 individual Web services requires less than 0.08 seconds, using the same computational power. Finally, a comparison with two popular reinforcement learning algorithms, sarsa and Q-learning, shows that these algorithms require one or two orders of magnitude and more time than policy iteration, iterative policy evaluation, and value iteration to handle WSC problems of the same complexity.

  11. A comparison of positive and negative alcohol expectancy and value and their multiplicative composite as predictors of post-treatment abstinence survivorship.

    PubMed

    Jones, B T; McMahon, J

    1996-01-01

    Within social learning theory, positive alcohol expectancies represent motivation to drink and negative expectancies, motivation to restrain. It is also recognized that a subjective evaluation of expectancies ought to moderate their impact, although the evidence for this in social drinkers is problematic. This paper addresses the speculation that the moderating effect will be more evident in clinical populations. This study shows that (i) both expectancy and value reliably, independently and equally predict clients' abstinence survivorship following discharge from a treatment programme (and that this is almost entirely confined to the negative rather than positive terms). When (ii) expectancy evaluations are processed against expectancy through multiplicative composites (i.e. expectancy x value), their predictive power is only equivalent to either expectancy or value on its own. However (iii) when the multiplicative composite is assessed following the statistical guidelines advocated by Evans (1991) (i.e. within the same model as its constituents, expectancy and value) the increase in outcome variance explained by its inclusion is negligible and casts doubt upon its use in alcohol research. This does not appear to apply to value, however, and its possible role in treatment is discussed.

  12. Reliability based impact localization in composite panels using Bayesian updating and the Kalman filter

    NASA Astrophysics Data System (ADS)

    Morse, Llewellyn; Sharif Khodaei, Zahra; Aliabadi, M. H.

    2018-01-01

    In this work, a reliability based impact detection strategy for a sensorized composite structure is proposed. Impacts are localized using Artificial Neural Networks (ANNs) with recorded guided waves due to impacts used as inputs. To account for variability in the recorded data under operational conditions, Bayesian updating and Kalman filter techniques are applied to improve the reliability of the detection algorithm. The possibility of having one or more faulty sensors is considered, and a decision fusion algorithm based on sub-networks of sensors is proposed to improve the application of the methodology to real structures. A strategy for reliably categorizing impacts into high energy impacts, which are probable to cause damage in the structure (true impacts), and low energy non-damaging impacts (false impacts), has also been proposed to reduce the false alarm rate. The proposed strategy involves employing classification ANNs with different features extracted from captured signals used as inputs. The proposed methodologies are validated by experimental results on a quasi-isotropic composite coupon impacted with a range of impact energies.

  13. Validity and reliability of a video questionnaire to assess physical function in older adults.

    PubMed

    Balachandran, Anoop; N Verduin, Chelsea; Potiaumpai, Melanie; Ni, Meng; Signorile, Joseph F

    2016-08-01

    Self-report questionnaires are widely used to assess physical function in older adults. However, they often lack a clear frame of reference and hence interpreting and rating task difficulty levels can be problematic for the responder. Consequently, the usefulness of traditional self-report questionnaires for assessing higher-level functioning is limited. Video-based questionnaires can overcome some of these limitations by offering a clear and objective visual reference for the performance level against which the subject is to compare his or her perceived capacity. Hence the purpose of the study was to develop and validate a novel, video-based questionnaire to assess physical function in older adults independently living in the community. A total of 61 community-living adults, 60years or older, were recruited. To examine validity, 35 of the subjects completed the video questionnaire, two types of physical performance tests: a test of instrumental activity of daily living (IADL) included in the Short Physical Functional Performance battery (PFP-10), and a composite of 3 performance tests (30s chair stand, single-leg balance and usual gait speed). To ascertain reliability, two-week test-retest reliability was assessed in the remaining 26 subjects who did not participate in validity testing. The video questionnaire showed a moderate correlation with the IADLs (Spearman rho=0.64, p<0.001; 95% CI (0.4, 0.8)), and a lower correlation with the composite score of physical performance tests (Spearman rho=0.49, p<0.01; 95% CI (0.18, 0.7)). The test-retest assessment yielded an intra-class correlation (ICC) of 0.87 (p<0.001; 95% CI (0.70, 0.94)) and a Cronbach's alpha of 0.89 demonstrating good reliability and internal consistency. Our results show that the video questionnaire developed to evaluate physical function in community-living older adults is a valid and reliable assessment tool; however, further validation is needed for definitive conclusions. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Assessing the predictive value of the American Board of Family Practice In-training Examination.

    PubMed

    Replogle, William H; Johnson, William D

    2004-03-01

    The American Board of Family Practice In-training Examination (ABFP ITE) is a cognitive examination similar in content to the ABFP Certification Examination (CE). The ABFP ITE is widely used in family medicine residency programs. It was originally developed and intended to be used for assessment of groups of residents. Despite lack of empirical support, however, some residency programs are using ABFP ITE scores as individual resident performance indicators. This study's objective was to estimate the positive predictive value of the ABFP ITE for identifying residents at risk for poor performance on the ABFP CE or a subsequent ABFP ITE. We used a normal distribution model for correlated test scores and Monte Carlo simulation to investigate the effect of test reliability (measurement errors) on the positive predictive value of the ABFP ITE. The positive predictive value of the composite score was .72. The positive predictive value of the eight specialty subscales ranged from .26 to .57. Only the composite score of the ABFP ITE has acceptable positive predictive value to be used as part of a comprehension resident evaluation system. The ABFP ITE specialty subscales do not have sufficient positive predictive value or reliability to warrant use as performance indicators.

  15. Evaluation of physical activity measures used in middle-aged women.

    PubMed

    Pettee Gabriel, Kelley; McClain, James J; Lee, Chong D; Swan, Pamela D; Alvar, Brent A; Mitros, Melanie R; Ainsworth, Barbara E

    2009-07-01

    To evaluate the reliability and validity of five commonly used physical activity questionnaires (PAQ) in women aged 45-65 yr with varying physical activity (PA) levels. Data were obtained from the Evaluation of Physical Activity Measures in Middle-aged Women (PAW) Study and included 66 women (aged 52.6 +/- 5.4 yr). PAQ evaluated include Modifiable Activity Questionnaire (past week and past month version), Nurses' Health Study PAQ, Active Australia Survey, and Women's Health Initiative PAQ. Intraclass correlation coefficients (ICC) between administrations of the PAQ were used to assess test-retest reliability. Spearman rank-order correlation coefficients were used to examine the associations of PA and physical fitness data with PAQ summary estimates. Accelerometer-determined median (25th, 75th percentiles) times (min.d) spent in moderate-lifestyle [760-1951 counts (ct)], moderate-walk (1952-5724 ct), vigorous (> or =5725 ct), and combined moderate and vigorous PA (MVPA > or = 1952 ct) during the 35 d of observation were 66.0 (51.2, 81.3), 23.1 (14.1, 34.6), 0.4 (0.0, 2.3), and 24.3 (15.9, 41.6) min, respectively. The PAQ were shown to be reproducible and relatively stable over time (ICC = 0.32 to 0.91) and were associated with total counts per day (ct.d, 0.46 to 0.60, all P < 0.001), and most were associated with many facets of physical fitness, including cardiorespiratory fitness (0.36 to 0.46, P < 0.01), body composition (-0.27 to -0.34, P < 0.05), and muscular fatigue (-0.25 to -0.44, P < 0.05). The PAQ evaluated in this study were shown to be reliable and associated with PA and physical fitness measures. Current findings support the utility of these PAQ for PA assessment in research studies of middle-aged women.

  16. Validation of the Practice Environment Scale to the Brazilian culture.

    PubMed

    Gasparino, Renata C; Guirardello, Edinêis de B

    2017-07-01

    To validate the Brazilian version of the Practice Environment Scale. The Practice Environment Scale is a tool that evaluates the presence of characteristics that are favourable for professional nursing practice because a better work environment contributes to positive results for patients, professionals and institutions. Methodological study including 209 nurses. Validity was assessed via a confirmatory factor analysis using structural equation modelling, in which the correlations between the instrument and the following variables were tested: burnout, job satisfaction, safety climate, perception of quality of care and intention to leave the job. Subgroups were compared and the reliability was assessed using Cronbach's alpha and the composite reliability. Factor analysis resulted in exclusion of seven items. Significant correlations were obtained between the subscales and all variables in the study. The reliability was considered acceptable. The Brazilian version of the Practice Environment Scale is a valid and reliable tool used to assess the characteristics that promote professional nursing practice. Use of this tool in Brazilian culture should allow managers to implement changes that contribute to the achievement of better results, in addition to identifying and comparing the environments of health institutions. © 2017 John Wiley & Sons Ltd.

  17. Hydrolysis condensation reactions of titanium alkoxides in thin films: A study of the steric hindrance effect by X-ray photoelectron spectroscopy

    NASA Astrophysics Data System (ADS)

    Barlier, Vincent; Bounor-Legaré, Véronique; Boiteux, Gisèle; Davenas, Joël; Léonard, Didier

    2008-06-01

    An original approach based on X-ray photoelectron spectroscopy (XPS) is proposed to study the influence of the surrounding humidity on the hydrolysis-condensation reactions of five titanium alkoxides in thin films. More precisely, the influence of the nature of the ligands (propoxide, butoxide, isopropoxide, phenoxide, and 9H-carbazole-9-yl-ethyl-oxy) on the reaction rate was evidenced. The reaction advancement was evaluated by comparing XPS chemical compositions to theoretical compositions calculated for all the possible rates. XPS chemical environment information allowed validating the reliability of this approach through the evaluation of the condensation state. In both approaches, the influence of the steric hindrance on the reactivity of titanium alkoxides was highlighted to be similar to what has been previously observed in solution. Theses results corroborate the validity of our XPS approach to determine titanium alkoxide hydrolysis-condensation reactions in the specific application of thin films.

  18. Quantitative measurement of carbon nanotubes released from their composites by thermal carbon analysis

    NASA Astrophysics Data System (ADS)

    Ogura, I.; Kotake, M.; Ata, S.; Honda, K.

    2017-06-01

    The release of free carbon nanotubes (CNTs) and CNTs partly embedded in matrix debris into the air may occur during mechanical and abrasion processes involving CNT composites. Since the harmful effects of CNT-matrix mixtures have not yet been fully evaluated, it is considered that any exposure to CNTs, including CNT-matrix mixtures, should be measured and controlled. Thermal carbon analysis, such as Method 5040 of the National Institute for Occupational Safety and Health, is one of the most reliable quantitative methods for measuring CNTs in the air. However, when CNTs are released together with polymer matrices, this technique may be inapplicable. In this study, we evaluated the potential for using thermal carbon analysis to determine CNTs in the presence of polymer matrices. Our results showed that thermal carbon analysis was potentially capable of determining CNTs in distinction from polyamide 12, polybutylene terephthalate, polypropylene, and polyoxymethylene. However, it was difficult to determine CNTs in the presence of polyethylene terephthalate, polycarbonate, polyetheretherketone, or polyamide 6.

  19. [Psychometric validation in Spanish of the Brazilian short version of the Primary Care Assessment Tools-users questionnaire for the evaluation of the orientation of health systems towards primary care].

    PubMed

    Vázquez Peña, Fernando; Harzheim, Erno; Terrasa, Sergio; Berra, Silvina

    2017-02-01

    To validate the Brazilian short version of the PCAT for adult patients in Spanish. Analysis of secondary data from studies made to validate the extended version of the PCAT questionnaire. City of Córdoba, Argentina. Primary health care. The sample consisted of 46% of parents, whose children were enrolled in secondary education in three institutes in the city of Cordoba, and the remaining 54% were adult users of the National University of Cordoba Health Insurance. Pearson's correlation coefficient comparing the extended and short versions. Goodness-of-fit indices in confirmatory factor analysis, composite reliability, average variance extracted, and Cronbach's alpha values, in order to assess the construct validity and the reliability of the short version. The values of Pearson's correlation coefficient between this short version and the long version were high .818 (P<.001), implying a very good criterion validity. The indicators of good global adjustment to the confirmatory factor analysis were good. The value of composite reliability was good (.802), but under the variance media extracted: .3306, since 3 variables had weak factorials loads. The Cronbach's alpha was acceptable (.85). The short version of the PCAT-users developed in Brazil showed an acceptable psychometric performance in Spanish as a quick assessment tool, in a comparative study with the extended version. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  20. How reliable are Functional Movement Screening scores? A systematic review of rater reliability.

    PubMed

    Moran, Robert W; Schneiders, Anthony G; Major, Katherine M; Sullivan, S John

    2016-05-01

    Several physical assessment protocols to identify intrinsic risk factors for injury aetiology related to movement quality have been described. The Functional Movement Screen (FMS) is a standardised, field-expedient test battery intended to assess movement quality and has been used clinically in preparticipation screening and in sports injury research. To critically appraise and summarise research investigating the reliability of scores obtained using the FMS battery. Systematic literature review. Systematic search of Google Scholar, Scopus (including ScienceDirect and PubMed), EBSCO (including Academic Search Complete, AMED, CINAHL, Health Source: Nursing/Academic Edition), MEDLINE and SPORTDiscus. Studies meeting eligibility criteria were assessed by 2 reviewers for risk of bias using the Quality Appraisal of Reliability Studies checklist. Overall quality of evidence was determined using van Tulder's levels of evidence approach. 12 studies were appraised. Overall, there was a 'moderate' level of evidence in favour of 'acceptable' (intraclass correlation coefficient ≥0.6) inter-rater and intra-rater reliability for composite scores derived from live scoring. For inter-rater reliability of composite scores derived from video recordings there was 'conflicting' evidence, and 'limited' evidence for intra-rater reliability. For inter-rater reliability based on live scoring of individual subtests there was 'moderate' evidence of 'acceptable' reliability (κ≥0.4) for 4 subtests (Deep Squat, Shoulder Mobility, Active Straight-leg Raise, Trunk Stability Push-up) and 'conflicting' evidence for the remaining 3 (Hurdle Step, In-line Lunge, Rotary Stability). This review found 'moderate' evidence that raters can achieve acceptable levels of inter-rater and intra-rater reliability of composite FMS scores when using live ratings. Overall, there were few high-quality studies, and the quality of several studies was impacted by poor study reporting particularly in relation to rater blinding. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Preliminary Development of a Multidimensional Semantic Patient Experience Measurement Questionnaire.

    PubMed

    Kleiss, James A

    2016-10-01

    The purpose of this research was to assess the utility and reliability of a multidimensional patient experience measurement questionnaire in a clinical setting. Patient experience has emerged as an important metric for quality of healthcare. A number of separate concepts have been used to measure patient experience, but psychological research suggests that subjective experience is actually a composite of several independent concepts including: (a) evaluation/valence, (b) potency/control, (c) activity/arousal, and (d) novelty. The present research evaluates the reliability of a multidimensional patient experience measurement questionnaire in a clinical setting. A multidimensional semantic differential questionnaire was developed to measure the four underlying semantic dimensions of patient experience mentioned above. A group of 60 patients used the questionnaire to assess prescan expectations and postscan experience of a magnetic resonance scan. Data for one patient were deleted because their scan was interrupted. Results revealed more positive evaluation/valence, higher potency/control, and lower activity/arousal for postscan ratings compared to prescan expectations. Ratings of novelty were neutral in both the prescan and the postscan conditions. Subsequent analysis suggested that internal consistency for some concepts could be improved by replacing several specific rating scales. Present results provide evidence of the utility and reliability of a multidimensional semantic questionnaire for measuring patient experience in an actual clinical setting. Recommendations to improve internal consistency for the concepts potency/control, activity/arousal, and novelty were also provided. © The Author(s) 2016.

  2. An Evaluation Method of Equipment Reliability Configuration Management

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Feng, Weijia; Zhang, Wei; Li, Yuan

    2018-01-01

    At present, many equipment development companies have been aware of the great significance of reliability of the equipment development. But, due to the lack of effective management evaluation method, it is very difficult for the equipment development company to manage its own reliability work. Evaluation method of equipment reliability configuration management is to determine the reliability management capabilities of equipment development company. Reliability is not only designed, but also managed to achieve. This paper evaluates the reliability management capabilities by reliability configuration capability maturity model(RCM-CMM) evaluation method.

  3. Synchrotron radiation microbeam X-ray diffraction for nondestructive assessments of local structural properties of faceted InGaN/GaN quantum wells

    NASA Astrophysics Data System (ADS)

    Sakaki, Atsushi; Funato, Mitsuru; Kawamura, Tomoaki; Araki, Jun; Kawakami, Yoichi

    2018-03-01

    Synchrotron radiation (SR) X-ray diffraction with a sub-µm spatial resolution is used to nondestructively evaluate the local thickness and alloy composition of three-dimensionally faceted InGaN/GaN quantum wells (QWs). The (0001) facet QW on a trapezoidal structure composed of (0001), \\{ 11\\bar{2}2\\} , and \\{ 11\\bar{2}0\\} facets is nonuniform, most likely owing to the migration of adatoms between facets. The thickness and composition markedly vary within a short distance for the \\{ 11\\bar{2}2\\} facet QW of another pyramidal structure. The QW parameters acquired by SR microbeam X-ray diffraction reproduce the local emission property assessed by cathodoluminescence, thereby indicating the high reliability of this method.

  4. Probabilistic load simulation: Code development status

    NASA Astrophysics Data System (ADS)

    Newell, J. F.; Ho, H.

    1991-05-01

    The objective of the Composite Load Spectra (CLS) project is to develop generic load models to simulate the composite load spectra that are included in space propulsion system components. The probabilistic loads thus generated are part of the probabilistic design analysis (PDA) of a space propulsion system that also includes probabilistic structural analyses, reliability, and risk evaluations. Probabilistic load simulation for space propulsion systems demands sophisticated probabilistic methodology and requires large amounts of load information and engineering data. The CLS approach is to implement a knowledge based system coupled with a probabilistic load simulation module. The knowledge base manages and furnishes load information and expertise and sets up the simulation runs. The load simulation module performs the numerical computation to generate the probabilistic loads with load information supplied from the CLS knowledge base.

  5. [Sampling optimization for tropical invertebrates: an example using dung beetles (Coleoptera: Scarabaeinae) in Venezuela].

    PubMed

    Ferrer-Paris, José Rafael; Sánchez-Mercado, Ada; Rodríguez, Jon Paul

    2013-03-01

    The development of efficient sampling protocols is an essential prerequisite to evaluate and identify priority conservation areas. There are f ew protocols for fauna inventory and monitoring in wide geographical scales for the tropics, where the complexity of communities and high biodiversity levels, make the implementation of efficient protocols more difficult. We proposed here a simple strategy to optimize the capture of dung beetles, applied to sampling with baited traps and generalizable to other sampling methods. We analyzed data from eight transects sampled between 2006-2008 withthe aim to develop an uniform sampling design, that allows to confidently estimate species richness, abundance and composition at wide geographical scales. We examined four characteristics of any sampling design that affect the effectiveness of the sampling effort: the number of traps, sampling duration, type and proportion of bait, and spatial arrangement of the traps along transects. We used species accumulation curves, rank-abundance plots, indicator species analysis, and multivariate correlograms. We captured 40 337 individuals (115 species/morphospecies of 23 genera). Most species were attracted by both dung and carrion, but two thirds had greater relative abundance in traps baited with human dung. Different aspects of the sampling design influenced each diversity attribute in different ways. To obtain reliable richness estimates, the number of traps was the most important aspect. Accurate abundance estimates were obtained when the sampling period was increased, while the spatial arrangement of traps was determinant to capture the species composition pattern. An optimum sampling strategy for accurate estimates of richness, abundance and diversity should: (1) set 50-70 traps to maximize the number of species detected, (2) get samples during 48-72 hours and set trap groups along the transect to reliably estimate species abundance, (3) set traps in groups of at least 10 traps to suitably record the local species composition, and (4) separate trap groups by a distance greater than 5-10km to avoid spatial autocorrelation. For the evaluation of other sampling protocols we recommend to, first, identify the elements of sampling design that could affect the sampled effort (the number of traps, sampling duration, type and proportion of bait) and their spatial distribution (spatial arrangement of the traps) and then, to evaluate how they affect richness, abundance and species composition estimates.

  6. Direct Resin Composite Restoration of Maxillary Central Incisors with Fractured Tooth Fragment Reattachment: Case Report.

    PubMed

    Szmidt, Monika; Górski, Maciej; Barczak, Katarzyna; Buczkowska-Radlińska, Jadwiga

    This article presents a clinical protocol to reconstruct two accidentally damaged maxillary central incisors using composite resin material and a fractured tooth component. A patient was referred to the clinic with fracture of the two maxillary central incisors. Clinical examination revealed that both teeth were fractured in the middle third of the crown and that the fractures involved enamel and dentin with no pulp exposure. The patient had also suffered a lower lip laceration. When the lip was evaluated, a fractured fragment of the maxillary right central incisor was found inside the wound. The missing part of the tooth was replaced via adhesive attachment. Due to the damage of the fractured part of the maxillary left central incisor, direct composite restoration of this tooth was performed. With the advent of adhesive dentistry, the process of fragment reattachment has become simplified and more reliable. This procedure provides improved function, is faster to perform, and provides long-lasting effects, indicating that reattachment of a coronal fragment is a realistic alternative to placement of conventional resin composite restorations.

  7. Reliability and Validity of Composite Scores from the NIH Toolbox Cognition Battery in Adults

    PubMed Central

    Heaton, Robert K.; Akshoomoff, Natacha; Tulsky, David; Mungas, Dan; Weintraub, Sandra; Dikmen, Sureyya; Beaumont, Jennifer; Casaletto, Kaitlin B.; Conway, Kevin; Slotkin, Jerry; Gershon, Richard

    2014-01-01

    This study describes psychometric properties of the NIH Toolbox Cognition Battery (NIHTB-CB) Composite Scores in an adult sample. The NIHTB-CB was designed for use in epidemiologic studies and clinical trials for ages 3 to 85. A total of 268 self-described healthy adults were recruited at four university-based sites, using stratified sampling guidelines to target demographic variability for age (20–85 years), gender, education, and ethnicity. The NIHTB-CB contains seven computer-based instruments assessing five cognitive sub-domains: Language, Executive Function, Episodic Memory, Processing Speed, and Working Memory. Participants completed the NIHTB-CB, corresponding gold standard validation measures selected to tap the same cognitive abilities, and sociodemographic questionnaires. Three Composite Scores were derived for both the NIHTB-CB and gold standard batteries: “Crystallized Cognition Composite,” “Fluid Cognition Composite,” and “Total Cognition Composite” scores. NIHTB Composite Scores showed acceptable internal consistency (Cronbach’s alphas = 0.84 Crystallized, 0.83 Fluid, 0.77 Total), excellent test–retest reliability (r: 0.86–0.92), strong convergent (r: 0.78–0.90) and discriminant (r: 0.19–0.39) validities versus gold standard composites, and expected age effects (r = 0.18 crystallized, r = − 0.68 fluid, r = − 0.26 total). Significant relationships with self-reported prior school difficulties and current health status, employment, and presence of a disability provided evidence of external validity. The NIH Toolbox Cognition Battery Composite Scores have excellent reliability and validity, suggesting they can be used effectively in epidemiologic and clinical studies. PMID:24960398

  8. Radiopacity of flowable composite by a digital technique.

    PubMed

    Dukić, W; Delija, B; Lešić, S; Dubravica, I; Derossi, D

    2013-01-01

    The aim of this in vitro study was to evaluate the radiopacity of 19 current dental flowable composite materials by a digital technique. Digital radiographs were obtained with a CCD sensor using an aluminum step wedge, a 1-mm-thick tooth slice, and a 1-mm-thick flowable composite specimen using five different combinations of exposure and voltage. The radiopacity in pixels was determined using Digora 2.6. software. The equivalent thickness of aluminum for each material was then calculated based on the calibration curve. All of the tested flowable composite materials had higher radiopacities than that of dentin, but in almost every combination of exposure and voltage, there were some composite materials that exhibited radiopacities equal to or slightly greater than enamel p>α; α=0.01). Of the flowable composite materials tested, 37% showed lower radiopacities than enamel, and 21% of the tested materials had higher radiopacities than the 3-mm aluminum equivalent. The highest radiopacity at all exposure values was produced by the Majesty Flow and Charisma Opal Flow materials, which had radiopacities almost twice that of enamel. Flowable composite materials should have radiopacities greater than that of enamel (ISO 4049), an important consideration for the introduction of new materials to the market. The digital radiopacity analysis techniques used in this study provide an easy, reliable, rapid, and precise method to characterize radiopacity of dental flowable composite materials.

  9. Comparability of Mayo-Portland Adaptability Inventory ratings by staff, significant others and people with acquired brain injury.

    PubMed

    Malec, James F

    2004-06-01

    To determine the internal consistency, reliability and comparability of the Mayo-Portland Adaptability Inventory (MPAI-4) and sub-scales completed by people with acquired brain injury (ABI), family and significant others (SO) and rehabilitation staff. 134 people with ABI consecutively seen for outpatient rehabilitation evaluation. MPAI-4 protocols based on independent ratings by the people with ABI undergoing evaluation, SO and rehabilitation staff were submitted to Rasch Facets analysis to determine the internal consistency of the overall measure and sub-scales (Ability, Adjustment and Participation indices) for each rater group and for a composite measure based on all rater groups. Rater agreement for individual items was also examined. Rasch indicators of internal consistency were entirely within acceptable limits for 3-rater composite full scale and sub-scale measures; these indicators were generally within acceptable limits for measures based on a single rater group. Item agreement was generally acceptable; disagreements suggested various sources of bias for specific rater groups. The MPAI-4 possesses satisfactory internal consistency regardless of rating source. A composite measure based on ratings made independently by people with ABI, SO and staff may serve as a 'gold standard' for research purposes. In the clinical setting, assessment of varying perspectives and biases may not only best represent outcome as evaluated by all parties involved but be essential to developing effective rehabilitation plans.

  10. The Comprehensive Care Project: Measuring Physician Performance in Ambulatory Practice

    PubMed Central

    Holmboe, Eric S; Weng, Weifeng; Arnold, Gerald K; Kaplan, Sherrie H; Normand, Sharon-Lise; Greenfield, Sheldon; Hood, Sarah; Lipner, Rebecca S

    2010-01-01

    Objective To investigate the feasibility, reliability, and validity of comprehensively assessing physician-level performance in ambulatory practice. Data Sources/Study Setting Ambulatory-based general internists in 13 states participated in the assessment. Study Design We assessed physician-level performance, adjusted for patient factors, on 46 individual measures, an overall composite measure, and composite measures for chronic, acute, and preventive care. Between- versus within-physician variation was quantified by intraclass correlation coefficients (ICC). External validity was assessed by correlating performance on a certification exam. Data Collection/Extraction Methods Medical records for 236 physicians were audited for seven chronic and four acute care conditions, and six age- and gender-appropriate preventive services. Principal Findings Performance on the individual and composite measures varied substantially within (range 5–86 percent compliance on 46 measures) and between physicians (ICC range 0.12–0.88). Reliabilities for the composite measures were robust: 0.88 for chronic care and 0.87 for preventive services. Higher certification exam scores were associated with better performance on the overall (r = 0.19; p <.01), chronic care (r = 0.14, p = .04), and preventive services composites (r = 0.17, p = .01). Conclusions Our results suggest that reliable and valid comprehensive assessment of the quality of chronic and preventive care can be achieved by creating composite measures and by sampling feasible numbers of patients for each condition. PMID:20819110

  11. Manufacturing process modeling for composite materials and structures, Sandia blade reliability collaborative

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guest, Daniel A.; Cairns, Douglas S.

    2014-02-01

    The increased use and interest in wind energy over the last few years has necessitated an increase in the manufacturing of wind turbine blades. This increase in manufacturing has in many ways out stepped the current understanding of not only the materials used but also the manufacturing methods used to construct composite laminates. The goal of this study is to develop a list of process parameters which influence the quality of composite laminates manufactured using vacuum assisted resin transfer molding and to evaluate how they influence laminate quality. Known to be primary factors for the manufacturing process are resin flowmore » rate and vacuum pressure. An incorrect balance of these parameters will often cause porosity or voids in laminates that ultimately degrade the strength of the composite. Fiber waviness has also been seen as a major contributor to failures in wind turbine blades and is often the effect of mishandling during the lay-up process. Based on laboratory tests conducted, a relationship between these parameters and laminate quality has been established which will be a valuable tool in developing best practices and standard procedures for the manufacture of wind turbine blade composites.« less

  12. Simulation of guided-wave ultrasound propagation in composite laminates: Benchmark comparisons of numerical codes and experiment.

    PubMed

    Leckey, Cara A C; Wheeler, Kevin R; Hafiychuk, Vasyl N; Hafiychuk, Halyna; Timuçin, Doğan A

    2018-03-01

    Ultrasonic wave methods constitute the leading physical mechanism for nondestructive evaluation (NDE) and structural health monitoring (SHM) of solid composite materials, such as carbon fiber reinforced polymer (CFRP) laminates. Computational models of ultrasonic wave excitation, propagation, and scattering in CFRP composites can be extremely valuable in designing practicable NDE and SHM hardware, software, and methodologies that accomplish the desired accuracy, reliability, efficiency, and coverage. The development and application of ultrasonic simulation approaches for composite materials is an active area of research in the field of NDE. This paper presents comparisons of guided wave simulations for CFRP composites implemented using four different simulation codes: the commercial finite element modeling (FEM) packages ABAQUS, ANSYS, and COMSOL, and a custom code executing the Elastodynamic Finite Integration Technique (EFIT). Benchmark comparisons are made between the simulation tools and both experimental laser Doppler vibrometry data and theoretical dispersion curves. A pristine and a delamination type case (Teflon insert in the experimental specimen) is studied. A summary is given of the accuracy of simulation results and the respective computational performance of the four different simulation tools. Published by Elsevier B.V.

  13. Concurrent Probabilistic Simulation of High Temperature Composite Structural Response

    NASA Technical Reports Server (NTRS)

    Abdi, Frank

    1996-01-01

    A computational structural/material analysis and design tool which would meet industry's future demand for expedience and reduced cost is presented. This unique software 'GENOA' is dedicated to parallel and high speed analysis to perform probabilistic evaluation of high temperature composite response of aerospace systems. The development is based on detailed integration and modification of diverse fields of specialized analysis techniques and mathematical models to combine their latest innovative capabilities into a commercially viable software package. The technique is specifically designed to exploit the availability of processors to perform computationally intense probabilistic analysis assessing uncertainties in structural reliability analysis and composite micromechanics. The primary objectives which were achieved in performing the development were: (1) Utilization of the power of parallel processing and static/dynamic load balancing optimization to make the complex simulation of structure, material and processing of high temperature composite affordable; (2) Computational integration and synchronization of probabilistic mathematics, structural/material mechanics and parallel computing; (3) Implementation of an innovative multi-level domain decomposition technique to identify the inherent parallelism, and increasing convergence rates through high- and low-level processor assignment; (4) Creating the framework for Portable Paralleled architecture for the machine independent Multi Instruction Multi Data, (MIMD), Single Instruction Multi Data (SIMD), hybrid and distributed workstation type of computers; and (5) Market evaluation. The results of Phase-2 effort provides a good basis for continuation and warrants Phase-3 government, and industry partnership.

  14. Viscoelastic behaviour of hydrogel-based composites for tissue engineering under mechanical load.

    PubMed

    Kocen, Rok; Gasik, Michael; Gantar, Ana; Novak, Saša

    2017-03-06

    Along with biocompatibility, bioinductivity and appropriate biodegradation, mechanical properties are also of crucial importance for tissue engineering scaffolds. Hydrogels, such as gellan gum (GG), are usually soft materials, which may benefit from the incorporation of inorganic particles, e.g. bioactive glass, not only due to the acquired bioactivity, but also due to improved mechanical properties. They exhibit complex viscoelastic properties, which can be evaluated in various ways. In this work, to reliably evaluate the effect of the bioactive glass (BAG) addition on viscoelastic properties of the composite hydrogel, we employed and compared the three most commonly used techniques, analyzing their advantages and limitations: monotonic uniaxial unconfined compression, small amplitude oscillatory shear (SAOS) rheology and dynamic mechanical analysis (DMA). Creep and small amplitude dynamic strain-controlled tests in DMA are suggested as the best ways for the characterization of mechanical properties of hydrogel composites, whereas the SAOS rheology is more useful for studying the hydrogel's processing kinetics, as it does not induce volumetric changes even at very high strains. Overall, the results confirmed a beneficial effect of BAG (nano)particles on the elastic modulus of the GG-BAG composite hydrogel. The Young's modulus of 6.6 ± 0.8 kPa for the GG hydrogel increased by two orders of magnitude after the addition of 2 wt.% BAG particles (500-800 kPa).

  15. Reliability and Construct Validity of Limits of Stability Test in Adolescents Using a Portable Forceplate System.

    PubMed

    Alsalaheen, Bara; Haines, Jamie; Yorke, Amy; Broglio, Steven P

    2015-12-01

    To examine the reliability, convergent, and discriminant validity of the limits of stability (LOS) test to assess dynamic postural stability in adolescents using a portable forceplate system. Cross-sectional reliability observational study. School setting. Adolescents (N=36) completed all measures during the first session. To examine the reliability of the LOS test, a subset of 15 participants repeated the LOS test after 1 week. Not applicable. Outcome measurements included the LOS test, Balance Error Scoring System, Instrumented Balance Error Scoring System, and Modified Clinical Test for Sensory Interaction on Balance. A significant relation was observed among LOS composite scores (r=.36-.87, P<.05). However, no relation was observed between LOS and static balance outcome measurements. The reliability of the LOS composite scores ranged from moderate to good (intraclass correlation coefficient model 2,1=.73-.96). The results suggest that the LOS composite scores provide unique information about dynamic postural stability, and the LOS test completed at 100% of the theoretical limit appeared to be a reliable test of dynamic postural stability in adolescents. Clinicians should use dynamic balance measurement as part of their balance assessment and should not use static balance testing (eg, Balance Error Scoring System) to make inferences about dynamic balance, especially when balance assessment is used to determine rehabilitation outcomes, or when making return to play decisions after injury. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  16. The Reliability of Microalloyed Sn-Ag-Cu Solder Interconnections Under Cyclic Thermal and Mechanical Shock Loading

    NASA Astrophysics Data System (ADS)

    Mattila, Toni T.; Hokka, Jussi; Paulasto-Kröckel, Mervi

    2014-11-01

    In this study, the performance of three microalloyed Sn-Ag-Cu solder interconnection compositions (Sn-3.1Ag-0.52Cu, Sn-3.0Ag-0.52Cu-0.24Bi, and Sn-1.1Ag-0.52Cu-0.1Ni) was compared under mechanical shock loading (JESD22-B111 standard) and cyclic thermal loading (40 ± 125°C, 42 min cycle) conditions. In the drop tests, the component boards with the low-silver nickel-containing composition (Sn-Ag-Cu-Ni) showed the highest average number of drops-to-failure, while those with the bismuth-containing alloy (Sn-Ag-Cu-Bi) showed the lowest. Results of the thermal cycling tests showed that boards with Sn-Ag-Cu-Bi interconnections performed the best, while those with Sn-Ag-Cu-Ni performed the worst. Sn-Ag-Cu was placed in the middle in both tests. In this paper, we demonstrate that solder strength is an essential reliability factor and that higher strength can be beneficial for thermal cycling reliability but detrimental to drop reliability. We discuss these findings from the perspective of the microstructures and mechanical properties of the three solder interconnection compositions and, based on a comprehensive literature review, investigate how the differences in the solder compositions influence the mechanical properties of the interconnections and discuss how the differences are reflected in the failure mechanisms under both loading conditions.

  17. Confirmatory Factor Analysis of the Malay Version of the Confusion, Hubbub and Order Scale (CHAOS-6) among Myocardial Infarction Survivors in a Malaysian Cardiac Healthcare Facility.

    PubMed

    Ganasegeran, Kurubaran; Selvaraj, Kamaraj; Rashid, Abdul

    2017-08-01

    The six item Confusion, Hubbub and Order Scale (CHAOS-6) has been validated as a reliable tool to measure levels of household disorder. We aimed to investigate the goodness of fit and reliability of a new Malay version of the CHAOS-6. The original English version of the CHAOS-6 underwent forward-backward translation into the Malay language. The finalised Malay version was administered to 105 myocardial infarction survivors in a Malaysian cardiac health facility. We performed confirmatory factor analyses (CFAs) using structural equation modelling. A path diagram and fit statistics were yielded to determine the Malay version's validity. Composite reliability was tested to determine the scale's reliability. All 105 myocardial infarction survivors participated in the study. The CFA yielded a six-item, one-factor model with excellent fit statistics. Composite reliability for the single factor CHAOS-6 was 0.65, confirming that the scale is reliable for Malay speakers. The Malay version of the CHAOS-6 was reliable and showed the best fit statistics for our study sample. We thus offer a simple, brief, validated, reliable and novel instrument to measure chaos, the Skala Kecelaruan, Keriuhan & Tertib Terubahsuai (CHAOS-6) , for the Malaysian population.

  18. Confirmatory Factor Analysis of the Malay Version of the Confusion, Hubbub and Order Scale (CHAOS-6) among Myocardial Infarction Survivors in a Malaysian Cardiac Healthcare Facility

    PubMed Central

    Ganasegeran, Kurubaran; Selvaraj, Kamaraj; Rashid, Abdul

    2017-01-01

    Background The six item Confusion, Hubbub and Order Scale (CHAOS-6) has been validated as a reliable tool to measure levels of household disorder. We aimed to investigate the goodness of fit and reliability of a new Malay version of the CHAOS-6. Methods The original English version of the CHAOS-6 underwent forward-backward translation into the Malay language. The finalised Malay version was administered to 105 myocardial infarction survivors in a Malaysian cardiac health facility. We performed confirmatory factor analyses (CFAs) using structural equation modelling. A path diagram and fit statistics were yielded to determine the Malay version’s validity. Composite reliability was tested to determine the scale’s reliability. Results All 105 myocardial infarction survivors participated in the study. The CFA yielded a six-item, one-factor model with excellent fit statistics. Composite reliability for the single factor CHAOS-6 was 0.65, confirming that the scale is reliable for Malay speakers. Conclusion The Malay version of the CHAOS-6 was reliable and showed the best fit statistics for our study sample. We thus offer a simple, brief, validated, reliable and novel instrument to measure chaos, the Skala Kecelaruan, Keriuhan & Tertib Terubahsuai (CHAOS-6), for the Malaysian population. PMID:28951688

  19. Reliability-Based Design Optimization of a Composite Airframe Component

    NASA Technical Reports Server (NTRS)

    Patnaik, Surya N.; Pai, Shantaram S.; Coroneos, Rula M.

    2009-01-01

    A stochastic design optimization methodology (SDO) has been developed to design components of an airframe structure that can be made of metallic and composite materials. The design is obtained as a function of the risk level, or reliability, p. The design method treats uncertainties in load, strength, and material properties as distribution functions, which are defined with mean values and standard deviations. A design constraint or a failure mode is specified as a function of reliability p. Solution to stochastic optimization yields the weight of a structure as a function of reliability p. Optimum weight versus reliability p traced out an inverted-S-shaped graph. The center of the inverted-S graph corresponded to 50 percent (p = 0.5) probability of success. A heavy design with weight approaching infinity could be produced for a near-zero rate of failure that corresponds to unity for reliability p (or p = 1). Weight can be reduced to a small value for the most failure-prone design with a reliability that approaches zero (p = 0). Reliability can be changed for different components of an airframe structure. For example, the landing gear can be designed for a very high reliability, whereas it can be reduced to a small extent for a raked wingtip. The SDO capability is obtained by combining three codes: (1) The MSC/Nastran code was the deterministic analysis tool, (2) The fast probabilistic integrator, or the FPI module of the NESSUS software, was the probabilistic calculator, and (3) NASA Glenn Research Center s optimization testbed CometBoards became the optimizer. The SDO capability requires a finite element structural model, a material model, a load model, and a design model. The stochastic optimization concept is illustrated considering an academic example and a real-life raked wingtip structure of the Boeing 767-400 extended range airliner made of metallic and composite materials.

  20. Thick thermal barrier coatings for diesel engines

    NASA Technical Reports Server (NTRS)

    Beardsley, M. Brad

    1995-01-01

    Caterpillar's approach to applying thick thermal barrier coatings (TTBC's) to diesel engine combustion chambers has been to use advanced modeling techniques to predict engine conditions and combine this information with fundamental property evaluation of TTBC systems to predict engine performance and TTBC stress states. Engine testing has been used to verify the predicted performance of the TTBC systems and provide information on failure mechanisms. The objective Caterpillar's program to date has been to advance the fundamental understanding of thick thermal barrier coating systems. Previous reviews of thermal barrier coating technology concluded that the current level of understanding of coating system behavior is inadequate and the lack of fundamental understanding may impeded the application of TTBC's to diesel engines. Areas of TTBC technology being examined in this program include powder characteristics and chemistry; bond coat composition; coating design, microstructure, and thickness as they affect properties, durability, and reliability; and TTBC 'aging' effects (microstructural and property changes) under diesel engine operating conditions. Methods to evaluate the reliability and durability of TTBC's have been developed that attempt to understand the fundamental strength of TTBC's for particular stress states.

  1. Thick thermal barrier coatings for diesel engines

    NASA Technical Reports Server (NTRS)

    Beardsley, M. B.

    1995-01-01

    Caterpillar's approach to applying Thick Thermal Barrier Coatings (TTBC's) to diesel engine combustion chambers has been to use advanced modeling techniques to predict engine conditions and combine this information with fundamental property evaluation of TTBC systems to predict engine performance and TTBC stress states. Engine testing has been used to verify the predicted performance of the TTBC systems and provide information on failure mechanisms. The objective of Caterpillar's subcontract with ORNL is to advance the fundamental understanding of thick thermal barrier coating systems. Previous reviews of thermal barrier coating technology concluded that the current level of understanding of coating system behavior is inadequate and the lack of fundamental understanding may impede the application of TTBC's to diesel engines. Areas of TTBC technology being examined in this program include powder characteristics and chemistry; bond coat composition; coating design, microstructure, and thickness as they affect properties, durability, and reliability; and TTBC 'aging' effects (microstructural and property changes) under diesel engine operating conditions. Methods to evaluate the reliability and durability of TTBC's have been developed that attempt to understand the fundamental strength of TTBC's for particular stress states.

  2. Structural design methodologies for ceramic-based material systems

    NASA Technical Reports Server (NTRS)

    Duffy, Stephen F.; Chulya, Abhisak; Gyekenyesi, John P.

    1991-01-01

    One of the primary pacing items for realizing the full potential of ceramic-based structural components is the development of new design methods and protocols. The focus here is on low temperature, fast-fracture analysis of monolithic, whisker-toughened, laminated, and woven ceramic composites. A number of design models and criteria are highlighted. Public domain computer algorithms, which aid engineers in predicting the fast-fracture reliability of structural components, are mentioned. Emphasis is not placed on evaluating the models, but instead is focused on the issues relevant to the current state of the art.

  3. Evaluation of Reaction Cross Section Data Used for Thin Layer Activation Technique

    NASA Astrophysics Data System (ADS)

    Ditrói, F.; Takács, S.; Tárkányi, F.

    2005-05-01

    Thin layer activation (TLA) is a widely used nuclear method to investigate and control the loss of material during wear, corrosion and erosion processes. The process requires knowledge of depth profiles of the investigated radioisotopes produced by charged particle bombardment. The depth distribution of the activity can be determined with direct, very time-consuming step by step measurement or by calculation from reliable cross section, stopping power and sample composition data. These data were checked experimentally at several points performing only a couple of measurements.

  4. Evaluation of Reaction Cross Section Data Used for Thin Layer Activation Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ditroi, F.; Takacs, S.; Tarkanyi, F.

    2005-05-24

    Thin layer activation (TLA) is a widely used nuclear method to investigate and control the loss of material during wear, corrosion and erosion processes. The process requires knowledge of depth profiles of the investigated radioisotopes produced by charged particle bombardment. The depth distribution of the activity can be determined with direct, very time-consuming step by step measurement or by calculation from reliable cross section, stopping power and sample composition data. These data were checked experimentally at several points performing only a couple of measurements.

  5. Platelet composite coatings for tin whisker mitigation

    DOE PAGES

    Rohwer, Lauren E. S.; Martin, James E.

    2015-09-14

    In this study, reliable methods for tin whisker mitigation are needed for applications that utilize tin-plated commercial components. Tin can grow whiskers that can lead to electrical shorting, possibly causing critical systems to fail catastrophically. The mechanisms of tin whisker growth are unclear and this makes prediction of the lifetimes of critical components uncertain. The development of robust methods for tin whisker mitigation is currently the best approach to eliminating the risk of shorting. Current mitigation methods are based on unfilled polymer coatings that are not impenetrable to tin whiskers. In this paper we report tin whisker mitigation results formore » several filled polymer coatings. The whisker-penetration resistance of the coatings was evaluated at elevated temperature and high humidity and under temperature cycling conditions. The composite coatings comprised Ni and MgF 2-coated Al/Ni/Al platelets in epoxy resin or silicone rubber. In addition to improved whisker mitigation, these platelet composites have enhanced thermal conductivity and dielectric constant compared with unfilled polymers.« less

  6. Platelet Composite Coatings for Tin Whisker Mitigation

    NASA Astrophysics Data System (ADS)

    Rohwer, Lauren E. S.; Martin, James E.

    2015-11-01

    Reliable methods for tin whisker mitigation are needed for applications that utilize tin-plated commercial components. Tin can grow whiskers that can lead to electrical shorting, possibly causing critical systems to fail catastrophically. The mechanisms of tin whisker growth are unclear and this makes prediction of the lifetimes of critical components uncertain. The development of robust methods for tin whisker mitigation is currently the best approach to eliminating the risk of shorting. Current mitigation methods are based on unfilled polymer coatings that are not impenetrable to tin whiskers. In this paper we report tin whisker mitigation results for several filled polymer coatings. The whisker-penetration resistance of the coatings was evaluated at elevated temperature and high humidity and under temperature cycling conditions. The composite coatings comprised Ni and MgF2-coated Al/Ni/Al platelets in epoxy resin or silicone rubber. In addition to improved whisker mitigation, these platelet composites have enhanced thermal conductivity and dielectric constant compared with unfilled polymers.

  7. Neutral monosaccharide composition analysis of plant-derived oligo- and polysaccharides by high performance liquid chromatography.

    PubMed

    Yan, Jun; Shi, Songshan; Wang, Hongwei; Liu, Ruimin; Li, Ning; Chen, Yonglin; Wang, Shunchun

    2016-01-20

    A novel analytical method for neutral monosaccharide composition analysis of plant-derived oligo- and polysaccharides was developed using hydrophilic interaction liquid chromatography coupled to a charged aerosol detector. The effects of column type, additives, pH and column temperature on retention and separation were evaluated. Additionally, the method could distinguish potential impurities in samples, including chloride, sulfate and sodium, from sugars. The results of validation demonstrated that this method had good linearity (R(2) ≥ 0.9981), high precision (relative standard deviation ≤ 4.43%), and adequate accuracy (94.02-103.37% recovery) and sensitivity (detection limit: 15-40 ng). Finally, the monosaccharide compositions of the polysaccharide from Eclipta prostrasta L. and stachyose were successfully profiled through this method. This report represents the first time that all of these common monosaccharides could be well-separated and determined simultaneously by high performance liquid chromatography without additional derivatization. This newly developed method is convenient, efficient and reliable for monosaccharide analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Nondestructive Methods and Special Test Instrumentation Supporting NASA Composite Overwrapped Pressure Vessel Assessments

    NASA Technical Reports Server (NTRS)

    Saulsberry, Regor; Greene, Nathanael; Cameron, Ken; Madaras, Eric; Grimes-Ledesma, Lorie; Thesken, John; Phoenix, Leigh; Murthy, Pappu; Revilock, Duane

    2007-01-01

    Many aging composite overwrapped pressure vessels (COPVs), being used by the National Aeronautics and Space Administration (NASA) are currently under evaluation to better quantify their reliability and clarify their likelihood of failure due to stress rupture and age-dependent issues. As a result, some test and analysis programs have been successfully accomplished and other related programs are still in progress at the NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) and other NASA centers, with assistance from the commercial sector. To support this effort, a group of Nondestructive Evaluation (NDE) experts was assembled to provide NDE competence for pretest evaluation of test articles and for application of NDE technology to real-time testing. Techniques were required to provide assurance that the test article had adequate structural integrity and manufacturing consistency to be considered acceptable for testing and these techniques were successfully applied. Destructive testing is also being accomplished to better understand the physical and chemical property changes associated with progression toward "stress rupture" (SR) failure, and it is being associated with NDE response, so it can potentially be used to help with life prediction. Destructive work also includes the evaluation of residual stresses during dissection of the overwrap, laboratory evaluation of specimens extracted from the overwrap to evaluate physical property changes, and quantitative microscopy to inform the theoretical micromechanics.

  9. Design of Composite Structures for Reliability and Damage Tolerance

    NASA Technical Reports Server (NTRS)

    Rais-Rohani, Masoud

    1999-01-01

    A summary of research conducted during the first year is presented. The research objectives were sought by conducting two tasks: (1) investigation of probabilistic design techniques for reliability-based design of composite sandwich panels, and (2) examination of strain energy density failure criterion in conjunction with response surface methodology for global-local design of damage tolerant helicopter fuselage structures. This report primarily discusses the efforts surrounding the first task and provides a discussion of some preliminary work involving the second task.

  10. Composite structural materials. [aircraft applications

    NASA Technical Reports Server (NTRS)

    Ansell, G. S.; Loewy, R. G.; Wiberley, S. E.

    1981-01-01

    The development of composite materials for aircraft applications is addressed with specific consideration of physical properties, structural concepts and analysis, manufacturing, reliability, and life prediction. The design and flight testing of composite ultralight gliders is documented. Advances in computer aided design and methods for nondestructive testing are also discussed.

  11. Correcting Coefficient Alpha for Correlated Errors: Is [alpha][K]a Lower Bound to Reliability?

    ERIC Educational Resources Information Center

    Rae, Gordon

    2006-01-01

    When errors of measurement are positively correlated, coefficient alpha may overestimate the "true" reliability of a composite. To reduce this inflation bias, Komaroff (1997) has proposed an adjusted alpha coefficient, ak. This article shows that ak is only guaranteed to be a lower bound to reliability if the latter does not include correlated…

  12. Interval Estimation of Revision Effect on Scale Reliability via Covariance Structure Modeling

    ERIC Educational Resources Information Center

    Raykov, Tenko

    2009-01-01

    A didactic discussion of a procedure for interval estimation of change in scale reliability due to revision is provided, which is developed within the framework of covariance structure modeling. The method yields ranges of plausible values for the population gain or loss in reliability of unidimensional composites, which results from deletion or…

  13. Evaluating cognition in individuals with Huntington disease: Neuro-QoL cognitive functioning measures.

    PubMed

    Lai, Jin-Shei; Goodnight, Siera; Downing, Nancy R; Ready, Rebecca E; Paulsen, Jane S; Kratz, Anna L; Stout, Julie C; McCormack, Michael K; Cella, David; Ross, Christopher; Russell, Jenna; Carlozzi, Noelle E

    2018-03-01

    Cognitive functioning impacts health-related quality of life (HRQOL) for individuals with Huntington disease (HD). The Neuro-QoL includes two patient-reported outcome (PRO) measures of cognition-Executive Function (EF) and General Concerns (GC). These measures have not previously been validated for use in HD. The purpose of this analysis is to evaluate the reliability and validity of the Neuro-QoL Cognitive Function measures for use in HD. Five hundred ten individuals with prodromal or manifest HD completed the Neuro-QoL Cognition measures, two other PRO measures of HRQOL (WHODAS 2.0 and EQ5D), and a depression measure (PROMIS Depression). Measures of functioning The Total Functional Capacity and behavior (Problem Behaviors Assessment) were completed by clinician interview. Objective measures of cognition were obtained using clinician-administered Symbol Digit Modalities Test and the Stroop Test (Word, Color, and Interference). Self-rated, clinician-rated, and objective composite scores were developed. We examined the Neuro-QoL measures for reliability, convergent validity, discriminant validity, and known-groups validity. Excellent reliabilities (Cronbach's alphas ≥ 0.94) were found. Convergent validity was supported, with strong relationships between self-reported measures of cognition. Discriminant validity was supported by less robust correlations between self-reported cognition and other constructs. Prodromal participants reported fewer cognitive problems than manifest groups, and early-stage HD participants reported fewer problems than late-stage HD participants. The Neuro-QoL Cognition measures provide reliable and valid assessments of self-reported cognitive functioning for individuals with HD. Findings support the utility of these measures for assessing self-reported cognition.

  14. WHO Study on the reliability and validity of the alcohol and drug use disorder instruments: overview of methods and results.

    PubMed

    Ustün, B; Compton, W; Mager, D; Babor, T; Baiyewu, O; Chatterji, S; Cottler, L; Göğüş, A; Mavreas, V; Peters, L; Pull, C; Saunders, J; Smeets, R; Stipec, M R; Vrasti, R; Hasin, D; Room, R; Van den Brink, W; Regier, D; Blaine, J; Grant, B F; Sartorius, N

    1997-09-25

    The WHO Study on the reliability and validity of the alcohol and drug use disorder instruments in an international study which has taken place in centres in ten countries, aiming to test the reliability and validity of three diagnostic instruments for alcohol and drug use disorders: the Composite International Diagnostic Interview (CIDI), the Schedules for Clinical Assessment in Neuropsychiatry (SCAN) and a special version of the Alcohol Use Disorder and Associated Disabilities Interview schedule-alcohol/drug-revised (AUDADIS-ADR). The purpose of the reliability and validity (R&V) study is to further develop the alcohol and drug sections of these instruments so that a range of substance-related diagnoses can be made in a systematic, consistent, and reliable way. The study focuses on new criteria proposed in the tenth revision of the International Classification of Diseases (ICD-10) and the fourth revision of the diagnostic and statistical manual of mental disorders (DSM-IV) for dependence, harmful use and abuse categories for alcohol and psychoactive substance use disorders. A systematic study including a scientifically rigorous measure of reliability (i.e. 1 week test-retest reliability) and validity (i.e. comparison between clinical and non-clinical measures) has been undertaken. Results have yielded useful information on reliability and validity of these instruments at diagnosis, criteria and question level. Overall the diagnostic concordance coefficients (kappa, kappa) were very good for dependence disorders (0.7-0.9), but were somewhat lower for the abuse and harmful use categories. The comparisons among instruments and independent clinical evaluations and debriefing interviews gave important information about possible sources of unreliability, and provided useful clues on the applicability and consistency of nosological concepts across cultures.

  15. Olfactory Cleft Endoscopy Scale correlates with olfactory metrics in patients with chronic rhinosinusitis

    PubMed Central

    Soler, Zachary M.; Hyer, J. Madison; Karnezis, Tom T.; Schlosser, Rodney J.

    2015-01-01

    Introduction Olfactory loss affects a majority of patients with chronic rhinosinusitis (CRS). Traditional objective measures of disease severity, including endoscopy scales, focus upon the paranasal sinuses and often have weak correlation to olfaction. Methods Adults with CRS were prospectively evaluated by blinded reviewers with a novel Olfactory Cleft Endoscopy Scale (OCES) that evaluated discharge, polyps, edema, crusting and scarring of the olfactory cleft. Objective olfactory function was assessed using “Sniffin’ Sticks testing, including composite threshold-discrimination-identification (TDI) scores. Olfactory-specific quality-of-life was evaluated using the short modified version of the Questionnaire of Olfactory Disorders (QOD-NS). Inter- and intra-rater reliability was assessed among 3 reviewers for OCES grading. Multivariate linear regression was then used to test associations between OCES scores and measures of olfaction, controlling for potential confounding factors. Results The OCES score was evaluated in 38 patients and had a high overall reliability (ICC=0.92; 95% CI: 0.91–0.96). The OCES significantly correlated with objective olfaction as measured by TDI score (p<0.001), with TDI score falling by 1.13 points for every 1 point increase in OCES score. Similar significant associations were found for threshold, discrimination, and identification scores (p<0.003 for all) after controlling for age, gender, race, and reviewer/review. The OCES was also highly associated with patient-reported QOD-NS scores (p=0.009). Conclusion A novel olfactory cleft endoscopy scale shows high reliability and correlates with both objective and patient-reported olfaction in patients with CRS. Further studies to determine prognostic value and responsiveness to change are warranted. PMID:26718315

  16. The impact of different types of textile liners used in protective footwear on the subjective sensations of firefighters.

    PubMed

    Irzmańska, Emilia

    2015-03-01

    The paper presents ergonomic evaluation of footwear used with three types of textile liners differing in terms of design and material composition. Two novel textile composite liners with enhanced hygienic properties were compared with a standard liner used in firefighter boots. The study involved 45 healthy firefighters from fire and rescue units who wore protective footwear with one of the three types of liners. The study was conducted in a laboratory under a normal atmosphere. The ergonomic properties of the protective footwear and liners were evaluated according to the standard EN ISO 20344:2012 as well as using an additional questionnaire concerning the thermal and moisture sensations experienced while wearing the footwear. The study was conducted on a much larger group of subjects (45) than that required by the ISO standard (3) to increase the reliability of subjective evaluations. Some statistically significant differences were found between the different types of textile liners used in firefighter boots. It was confirmed that the ergonomic properties of protective footwear worn in the workplace may be improved by the use of appropriate textile components. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  17. Abutment design for implant-supported indirect composite molar crowns: reliability and fractography.

    PubMed

    Bonfante, Estevam Augusto; Suzuki, Marcelo; Lubelski, William; Thompson, Van P; de Carvalho, Ricardo Marins; Witek, Lukasz; Coelho, Paulo G

    2012-12-01

    To investigate the reliability of titanium abutments veneered with indirect composites for implant-supported crowns and the possibility to trace back the fracture origin by qualitative fractographic analysis. Large base (LB) (6.4-mm diameter base, with a 4-mm high cone in the center for composite retention), small base (SB-4) (5.2-mm base, 4-mm high cone), and small base with cone shortened to 2 mm (SB-2) Ti abutments were used. Each abutment received incremental layers of indirect resin composite until completing the anatomy of a maxillary molar crown. Step-stress accelerated-life fatigue testing (n = 18 each) was performed in water. Weibull curves with use stress of 200 N for 50,000 and 100,000 cycles were calculated. Probability Weibull plots examined the differences between groups. Specimens were inspected in light-polarized and scanning electron microscopes for fractographic analysis. Use level probability Weibull plots showed Beta values of 0.27 for LB, 0.32 for SB-4, and 0.26 for SB-2, indicating that failures were not influenced by fatigue and damage accumulation. The data replotted as Weibull distribution showed no significant difference in the characteristic strengths between LB (794 N) and SB-4 abutments (836 N), which were both significantly higher than SB-2 (601 N). Failure mode was cohesive within the composite for all groups. Fractographic markings showed that failures initiated at the indentation area and propagated toward the margins of cohesively failed composite. Reliability was not influenced by abutment design. Qualitative fractographic analysis of the failed indirect composite was feasible. © 2012 by the American College of Prosthodontists.

  18. A two-factor theory for concussion assessment using ImPACT: memory and speed.

    PubMed

    Schatz, Philip; Maerlender, Arthur

    2013-12-01

    We present the initial validation of a two-factor structure of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) using ImPACT composite scores and document the reliability and validity of this factor structure. Factor analyses were conducted for baseline (N = 21,537) and post-concussion (N = 560) data, yielding "Memory" (Verbal and Visual) and "Speed" (Visual Motor Speed and Reaction Time) Factors; inclusion of Total Symptom Scores resulted in a third discrete factor. Speed and Memory z-scores were calculated, and test-retest reliability (using intra-class correlation coefficients) at 1 month (0.88/0.81), 1 year (0.85/0.75), and 2 years (0.76/0.74) were higher than published data using Composite scores. Speed and Memory scores yielded 89% sensitivity and 70% specificity, which was higher than composites (80%/62%) and comparable with subscales (91%/69%). This emergent two-factor structure has improved test-retest reliability with no loss of sensitivity/specificity and may improve understanding and interpretability of ImPACT test results.

  19. Quantifying complexity of financial short-term time series by composite multiscale entropy measure

    NASA Astrophysics Data System (ADS)

    Niu, Hongli; Wang, Jun

    2015-05-01

    It is significant to study the complexity of financial time series since the financial market is a complex evolved dynamic system. Multiscale entropy is a prevailing method used to quantify the complexity of a time series. Due to its less reliability of entropy estimation for short-term time series at large time scales, a modification method, the composite multiscale entropy, is applied to the financial market. To qualify its effectiveness, its applications in the synthetic white noise and 1 / f noise with different data lengths are reproduced first in the present paper. Then it is introduced for the first time to make a reliability test with two Chinese stock indices. After conducting on short-time return series, the CMSE method shows the advantages in reducing deviations of entropy estimation and demonstrates more stable and reliable results when compared with the conventional MSE algorithm. Finally, the composite multiscale entropy of six important stock indices from the world financial markets is investigated, and some useful and interesting empirical results are obtained.

  20. Composite structural materials

    NASA Technical Reports Server (NTRS)

    Ansell, G. S.; Wiberley, S. E.

    1978-01-01

    The purpose of the RPI composites program is to develop advanced technology in the areas of physical properties, structural concepts and analysis, manufacturing, reliability and life prediction. Concommitant goals are to educate engineers to design and use composite materials as normal or conventional materials. A multifaceted program was instituted to achieve these objectives.

  1. Coefficient alpha and interculture test selection.

    PubMed

    Thurber, Steven; Kishi, Yasuhiro

    2014-04-01

    The internal consistency reliability of a measure can be a focal point in an evaluation of the potential adequacy of an instrument for adaptation to another cultural setting. Cronbach's alpha (α) coefficient is often used as the statistical index for such a determination. However, alpha presumes a tau-equivalent test and may constitute an inaccurate population estimate for multidimensional tests. These notions are expanded and examined with a Japanese version of a questionnaire on nursing attitudes toward suicidal patients, originally constructed in Sweden using the English language. The English measure was reported to have acceptable internal consistency (α) albeit the dimensionality of the questionnaire was not addressed. The Japanese scale was found to lack tau-equivalence. An alternative to alpha, "composite reliability," was computed and found to be below acceptable standards in magnitude and precision. Implications for research application of the Japanese instrument are discussed. © The Author(s) 2012.

  2. Stress and reliability analyses of multilayered composite cylinder under thermal and mechanical loads

    NASA Astrophysics Data System (ADS)

    Wang, Xiaohua

    The coupling resulting from the mutual influence of material thermal and mechanical parameters is examined in the thermal stress analysis of a multilayered isotropic composite cylinder subjected to sudden axisymmetric external and internal temperature. The method of complex frequency response functions together with the Fourier transform technique is utilized. Because the coupling parameters for some composite materials, such as carbon-carbon, are very small, the effect of coupling is neglected in the orthotropic thermal stress analysis. The stress distributions in multilayered orthotropic cylinders subjected to sudden axisymmetric temperature loading combined with dynamic pressure as well as asymmetric temperature loading are also obtained. The method of Fourier series together with the Laplace transform is utilized in solving the heat conduction equation and thermal stress analysis. For brittle materials, like carbon-carbon composites, the strength variability is represented by two or three parameter Weibull distributions. The 'weakest link' principle which takes into account both the carbon-carbon composite cylinders. The complex frequency response analysis is performed on a multilayered orthotropic cylinder under asymmetrical thermal load. Both deterministic and random thermal stress and reliability analyses can be based on the results of this frequency response analysis. The stress and displacement distributions and reliability of rocket motors under static or dynamic line loads are analyzed by an elasticity approach. Rocket motors are modeled as long hollow multilayered cylinders with an air core, a thick isotropic propellant inner layer and a thin orthotropic kevlar-epoxy case. The case is treated as a single orthotropic layer or a ten layered orthotropic structure. Five material properties and the load are treated as random variable with normal distributions when the reliability of the rocket motor is analyzed by the first-order, second-moment method (FOSM).

  3. Elucidative analysis and sequencing of two respiratory health monitoring methods to study the impact of varying atmospheric composition on human health

    NASA Astrophysics Data System (ADS)

    Awasthi, Amit; Hothi, Navjot; Kaur, Prabhjot; Singh, Nirankar; Chakraborty, Monojit; Bansal, Sangeeta

    2017-12-01

    Atmospheric composition of ambient air consists of different gases in definite proportion that affect the earth's climate and its ecological system. Due to varied anthropogenic reasons, this composition is changed, which ultimately have an impact on the health of living beings. For survival, the human respiratory system is one of the sensitive systems, which is easily and closely affected by the change in atmospheric composition of an external environment. Many studies have been conducted to quantify the effects of atmospheric pollution on human health by using different approaches. This article presents different scenario of studies conducted to evaluate the effects on different human groups. Differences between the studies conducted using spirometry and survey methods are presented in this article to extract a better sequence between these two methodologies. Many studies have been conducted to measure the respiratory status by evaluating the respiratory symptoms and hospital admissions. Limited numbers of studies are found with repeated spirometry on the same subjects for long duration to nullify the error arising due to decrease in efforts by the same subjects during manoeuvre of pulmonary function tests. Present study reveals the importance of methodological sequencing in order to obtain more authentic and reliable results. This study suggests that impacts of deteriorating atmospheric composition on human health can be more significantly studied if spirometry is done after survey analysis. The article also proposes that efficiency and authenticity of surveys involving health impacts will increase, if medical data information of patients is saved in hospitals in a proper format.

  4. Evaluation of the durability of composite tidal turbine blades.

    PubMed

    Davies, Peter; Germain, Grégory; Gaurier, Benoît; Boisseau, Amélie; Perreux, Dominique

    2013-02-28

    The long-term reliability of tidal turbines is critical if these structures are to be cost effective. Optimized design requires a combination of material durability models and structural analyses. Composites are a natural choice for turbine blades, but there are few data available to predict material behaviour under coupled environmental and cycling loading. The present study addresses this problem, by introducing a multi-level framework for turbine blade qualification. At the material scale, static and cyclic tests have been performed, both in air and in sea water. The influence of ageing in sea water on fatigue performance is then quantified, and much lower fatigue lives are measured after ageing. At a higher level, flume tank tests have been performed on three-blade tidal turbines. Strain gauging of blades has provided data to compare with numerical models.

  5. Composition of Web Services Using Markov Decision Processes and Dynamic Programming

    PubMed Central

    Uc-Cetina, Víctor; Moo-Mena, Francisco; Hernandez-Ucan, Rafael

    2015-01-01

    We propose a Markov decision process model for solving the Web service composition (WSC) problem. Iterative policy evaluation, value iteration, and policy iteration algorithms are used to experimentally validate our approach, with artificial and real data. The experimental results show the reliability of the model and the methods employed, with policy iteration being the best one in terms of the minimum number of iterations needed to estimate an optimal policy, with the highest Quality of Service attributes. Our experimental work shows how the solution of a WSC problem involving a set of 100,000 individual Web services and where a valid composition requiring the selection of 1,000 services from the available set can be computed in the worst case in less than 200 seconds, using an Intel Core i5 computer with 6 GB RAM. Moreover, a real WSC problem involving only 7 individual Web services requires less than 0.08 seconds, using the same computational power. Finally, a comparison with two popular reinforcement learning algorithms, sarsa and Q-learning, shows that these algorithms require one or two orders of magnitude and more time than policy iteration, iterative policy evaluation, and value iteration to handle WSC problems of the same complexity. PMID:25874247

  6. On Multi-Objective Based Constitutive Modelling Methodology and Numerical Validation in Small-Hole Drilling of Al6063/SiCp Composites

    PubMed Central

    Xiang, Junfeng; Xie, Lijing; Gao, Feinong; Zhang, Yu; Yi, Jie; Wang, Tao; Pang, Siqin; Wang, Xibin

    2018-01-01

    Discrepancies in capturing material behavior of some materials, such as Particulate Reinforced Metal Matrix Composites, by using conventional ad hoc strategy make the applicability of Johnson-Cook constitutive model challenged. Despites applicable efforts, its extended formalism with more fitting parameters would increase the difficulty in identifying constitutive parameters. A weighted multi-objective strategy for identifying any constitutive formalism is developed to predict mechanical behavior in static and dynamic loading conditions equally well. These varying weighting is based on the Gaussian-distributed noise evaluation of experimentally obtained stress-strain data in quasi-static or dynamic mode. This universal method can be used to determine fast and directly whether the constitutive formalism is suitable to describe the material constitutive behavior by measuring goodness-of-fit. A quantitative comparison of different fitting strategies on identifying Al6063/SiCp’s material parameters is made in terms of performance evaluation including noise elimination, correlation, and reliability. Eventually, a three-dimensional (3D) FE model in small-hole drilling of Al6063/SiCp composites, using multi-objective identified constitutive formalism, is developed. Comparison with the experimental observations in thrust force, torque, and chip morphology provides valid evidence on the applicability of the developed multi-objective identification strategy in identifying constitutive parameters. PMID:29324688

  7. Analysis and Implementation of Accident Tolerant Nuclear Fuels

    NASA Astrophysics Data System (ADS)

    Prewitt, Benjamin Joseph

    To improve the reliability and robustness of LWR, accident tolerant nuclear fuels and cladding materials are being developed to possibly replace the current UO2/zirconium system. This research highlights UN and U3Si 2, two of the most favorable accident tolerant fuels being developed. To evaluate the commercial feasiblilty of these fuels, two areas of research were conducted. Chemical fabrication routes for both fuels were investigated in detail, considering UO2 and UF6 as potential starting materials. Potential pathways for industrial scale fabrication using these methods were discussed. Neutronic performance of 70%UN-30%U3Si2 composite was evaluated in MNCP using PWR assembly and core models. The results showed comparable performance to an identical UO2 fueled simulation with the same configuration. The parameters simulated for composite and oxide fuel include the following: fuel to moderator ratio curves; energy dependent flux spectra; temperature coefficients for fuel and moderator; delayed neutron fractions; power peaking factors; axial and radial flux profiles in 2D and 3D; burnup; critical boron concentration; and shutdown margin. Overall, the neutronic parameters suggest that the transition from UO2 to composite in existing nuclear systems will not require significant changes in operating procedures or modifications to standards and regulations.

  8. A probabilistic method to establish the reliability of carbon-carbon rocket motor nozzles. Volume 3: Stress and reliability analysis of layered composite cylinders under thermal shock

    NASA Astrophysics Data System (ADS)

    Heller, R. A.; Thangjitham, S.; Wang, X.

    1992-04-01

    The state of stress in a cylindrical structure consisting of multiple layers of carbon-carbon composite and subjected to thermal and pressure shock are analyzed using an elasticity approach. The reliability of the structure based on the weakest link concept and the Weibull distribution is also calculated. Coupled thermo-elasticity is first assumed and is shown to be unnecessary for the material considered. The effects of external and internal thermal shock as well as a superimposed pressure shock are examined. It is shown that for the geometry chosen, the structure may fail when exposed to thermal shock alone while a superimposed pressure shock can mitigate the probability of failure.

  9. Structural Integrity Evaluation of the Lear Fan 2100 Aircraft

    NASA Technical Reports Server (NTRS)

    Kan, H. P.; Dyer, T. A.

    1996-01-01

    An in-situ nondestructive inspection was conducted to detect manufacturing and assembly induced defects in the upper two wing surfaces (skin s) and upper fuselage skin of the Lear Fan 2100 aircraft E009. The effects of the defects, detected during the inspection, on the integrity of the structure was analytically evaluated. A systematic evaluation was also conducted to determine the damage tolerance capability of the upper wing skin against impact threats and assembly induced damage. The upper wing skin was divided into small regions for damage tolerance evaluations. Structural reliability, margin of safety, allowable strains, and allowable damage size were computed. The results indicated that the impact damage threat imposed on composite military aircraft structures is too severe for the Lear Fan 2100 upper wing skin. However, the structural integrity is not significantly degraded by the assembly induced damage for properly assembled structures, such as the E009 aircraft.

  10. Reliability of the Star Excursion Balance Test and Two New Similar Protocols to Measure Trunk Postural Control.

    PubMed

    López-Plaza, Diego; Juan-Recio, Casto; Barbado, David; Ruiz-Pérez, Iñaki; Vera-Garcia, Francisco J

    2018-05-18

    Although the Star Excursion Balance test (SEBT) has shown a good intrasession reliability, the intersession reliability of this test has not been deeply studied. Furthermore, there is an evident high influence of the lower limbs in the performance of the SEBT, so even if it has been used to measure core stability, it is possibly not the most suitable measurement. The aims of this study were to (1) to assess the absolute and relative between-session reliability of the SEBT and 2 novel variations of this test to assess trunk postural control while sitting, ie, the Star Excursion Sitting Test (SEST) and the Star Excursion Timing Test (SETT); and (2) to analyze the relationships between these 3 test scores. Correlational and reliability test-retest study. Controlled laboratory environment. Twenty-seven physically active men (age: 24.54 ± 3.05 years). Relative and absolute reliability of the SEBT, SEST, and SETT were calculated through the intraclass correlation coefficient (ICC) and standard error of measurement (SEM), respectively. A Pearson correlation analysis was carried out between the variables of the 3 tests. Maximum normalized reach distances were assessed for different SEBT and SEST directions. In addition, composite indexes were calculated for SEBT, SEST, and SETT. The SEBT (dominant leg: ICC = 0.87 [0.73-0.94], SEM = 2.12 [1.66-2.93]; nondominant leg: ICC = 0.74 [0.50-0.87], SEM = 3.23 [2.54-4.45]), SEST (ICC = 0.85 [0.68-0.92], SEM = 1.27 [1.03-1.80]), and SETT (ICC = 0.61 [0.30-0.80], SEM = 2.31 [1.82-3.17]) composite indexes showed moderate-to-high 1-month reliability. A learning effect was detected for some SEBT and SEST directions and for SEST and SETT composite indexes. No significant correlations were found between SEBT and its 2 variations (r ≤ .366; P > .05). A significant correlation was found between the SEST and SETT composite indexes (r = .520; P > .01). SEBT, SEST, and SETT are reliable field protocols to measure postural control. However, whereas the SEBT assesses postural control in single-leg stance, SEST and SETT provide trunk postural control measures with lower influence of the lower-limbs. To be determined. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  11. How we determined the most reliable solid medium for studying treatment of tuberculosis

    PubMed Central

    Heilig, Charles M.; Feng, Pei-Jean I.; Joloba, Moses L.; Johnson, John L.; Morgan, Karen; Gitta, Phineas; Boom, W. Henry; Mayanja-Kizza, Harriet; Eisenach, Kathleen D.; Bozeman, Lorna; Goldberg, Stefan V.

    2014-01-01

    Phase 2 clinical trials for tuberculosis (TB) treatment require reliable culture methods to determine presence or absence of Mycobacterium tuberculosis (Mtb) over the course of therapy, as these trials are based primarily on bacteriological endpoints. We evaluate which of 5 solid media is most reliable: Lowenstein-Jensen (LJ) egg-based medium and 4 Middlebrook agar media (nonselective 7H10 and 7H11 and selective 7H10 and 7H11). We analyze 393 specimens from 50 HIV-negative Ugandan adults with newly-diagnosed, pulmonary TB and high acid-fast bacillus smear grade. Specimens were collected every 2–4 weeks during the first 12 weeks of therapy. We compare the results for each culture to 2 composite reference standards—one that was deemed positive if any solid culture was positive for Mtb and another based on latent class analysis. Both reference standards established that the 2 selective Middlebrook media most reliably determine the presence or absence of Mtb (P<0.003), largely because of their lower contamination rates. We also showed that results on Middlebrook media were similar to each other, while LJ was most frequently discordant. Contaminated results appeared more likely to be truly negative than to harbor undetected Mtb. PMID:24661816

  12. How we determined the most reliable solid medium for studying treatment of tuberculosis.

    PubMed

    Heilig, Charles M; Feng, Pei-Jean I; Joloba, Moses L; Johnson, John L; Morgan, Karen; Gitta, Phineas; Boom, W Henry; Mayanja-Kizza, Harriet; Eisenach, Kathleen D; Bozeman, Lorna; Goldberg, Stefan V

    2014-05-01

    Phase 2 clinical trials for tuberculosis (TB) treatment require reliable culture methods to determine presence or absence of Mycobacterium tuberculosis (Mtb) over the course of therapy, as these trials are based primarily on bacteriological endpoints. We evaluate which of 5 solid media is most reliable: Lowenstein-Jensen (LJ) egg-base medium and 4 Middlebrook agar media (nonselective 7H10 and 7H11 and selective 7H10 and 7H11). We analyze 393 specimens from 50 HIV-negative Ugandan adults with newly-diagnosed, pulmonary TB and high acid-fast bacillus smear grade. Specimens were collected every 2-4 weeks during the first 12 weeks of therapy. We compare the results for each culture to 2 composite reference standards--one that was deemed positive if any solid culture was positive for Mtb and another based on latent-class analysis. Both reference standards established that the 2 selective Middlebrook media most reliably determine the presence or absence of Mtb (P < 0.003), largely because of their lower contamination rates. We also showed that results on Middlebrook media were similar to each other, while LJ was most frequently discordant. Contaminated results appeared more likely to be truly negative than to harbor undetected Mtb. Published by Elsevier Ltd.

  13. Comparing Fit and Reliability Estimates of a Psychological Instrument Using Second-Order CFA, Bifactor, and Essentially Tau-Equivalent (Coefficient Alpha) Models via AMOS 22

    ERIC Educational Resources Information Center

    Black, Ryan A.; Yang, Yanyun; Beitra, Danette; McCaffrey, Stacey

    2015-01-01

    Estimation of composite reliability within a hierarchical modeling framework has recently become of particular interest given the growing recognition that the underlying assumptions of coefficient alpha are often untenable. Unfortunately, coefficient alpha remains the prominent estimate of reliability when estimating total scores from a scale with…

  14. Ultrasonic Studies of Composites Undergoing Thermal and Fatigue Loading

    NASA Technical Reports Server (NTRS)

    Madaras, Eric I.; Winfree, William P.; Johnston, Patrick H.

    1997-01-01

    New composite materials possess attractive properties for use in advanced aircraft. A necessary requirement for their introduction into aeronautic use is an accurate understanding of their long term aging processes so that proper design criteria can be established. In order to understand those properties, these composites must be exposed to thermal and load cycles that are characteristic of flight conditions. Additionally, airline companies will require nondestructive evaluation (NDE) methods that can be used in the field to assess the condition of these new materials as they age. As part of an effort to obtain the required information about new composites for aviation use, we are performing ultrasonic measurements both in the NDE laboratory and in the materials testing laboratory at NASA. The materials testing laboratory is equipped with environmental chambers mounted on load frames so that composite samples can be exposed to thermal and loading cycles representative of flight protocols. Applying both temperature and load simultaneously will help to highlight temperature and load interactions during the aging of these composite materials. This study reports on our initial ultrasonic attenuation results from thermoset and thermoplastic composite samples. Ultrasonic attenuation measurements have been used reliably to assess the effects of material degradation. For example, recently, researchers have shown that by using frequencies of ultrasound on the order of 24 MHz, they could obtain adequate contrast in the evaluation of thermal degradation in these composites. This paper will present data that shows results at a lower frequency range. In addition, we report results on the frequency dependence of attenuation as the slope of attenuation with respect to frequency, beta = delta alpha (f) / delta f. The slope of attenuation is an attractive parameter since it is quantitative, yet does not require interface corrections like conventional quantitative attenuation measurements. This is a consequence of the assumption that interface correction terms are frequently independent. Uncertainty in those corrections terms compromises the value of conventional quantitative attenuation data.

  15. Proof test methodology for composites

    NASA Technical Reports Server (NTRS)

    Wu, Edward M.; Bell, David K.

    1992-01-01

    The special requirements for proof test of composites are identified based on the underlying failure process of composites. Two proof test methods are developed to eliminate the inevitable weak fiber sites without also causing flaw clustering which weakens the post-proof-test composite. Significant reliability enhancement by these proof test methods has been experimentally demonstrated for composite strength and composite life in tension. This basic proof test methodology is relevant to the certification and acceptance of critical composite structures. It can also be applied to the manufacturing process development to achieve zero-reject for very large composite structures.

  16. Development and psychometric evaluation of a health-related quality of life instrument for individuals with adult-onset hearing loss.

    PubMed

    Stika, Carren J; Hays, Ron D

    2015-07-01

    Self-reports of 'hearing handicap' are available, but a comprehensive measure of health-related quality of life (HRQOL) for individuals with adult-onset hearing loss (AOHL) does not exist. Our objective was to develop and evaluate a multidimensional HRQOL instrument for individuals with AOHL. The Impact of Hearing Loss Inventory Tool (IHEAR-IT) was developed using results of focus groups, a literature review, advisory expert panel input, and cognitive interviews. The 73-item field-test instrument was completed by 409 adults (22-91 years old) with varying degrees of AOHL and from different areas of the USA. Multitrait scaling analysis supported four multi-item scales and five individual items. Internal consistency reliabilities ranged from 0.93 to 0.96 for the scales. Construct validity was supported by correlations between the IHEAR-IT scales and scores on the 36-item Short Form Health Survey, version 2.0 (SF-36v2) mental composite summary (r = 0.32-0.64) and the Hearing Handicap Inventory for the Elderly/Adults (HHIE/HHIA) (r ≥ -0.70). The field test provides initial support for the reliability and construct validity of the IHEAR-IT for evaluating HRQOL of individuals with AOHL. Further research is needed to evaluate the responsiveness to change of the IHEAR-IT scales and identify items for a short-form.

  17. Student assessment by objective structured examination in a neurology clerkship

    PubMed Central

    Adesoye, Taiwo; Smith, Sandy; Blood, Angela; Brorson, James R.

    2012-01-01

    Objectives: We evaluated the reliability and predictive ability of an objective structured clinical examination (OSCE) in the assessment of medical students at the completion of a neurology clerkship. Methods: We analyzed data from 195 third-year medical students who took the OSCE. For each student, the OSCE consisted of 2 standardized patient encounters. The scores obtained from each encounter were compared. Faculty clinical evaluations of each student for 2 clinical inpatient rotations were also compared. Hierarchical regression analysis was applied to test the ability of the averaged OSCE scores to predict standardized written examination scores and composite clinical scores. Results: Students' OSCE scores from the 2 standardized patient encounters were significantly correlated with each other (r = 0.347, p < 0.001), and the scores for all students were normally distributed. In contrast, students' faculty clinical evaluation scores from 2 different clinical inpatient rotations were uncorrelated, and scores were skewed toward the highest ratings. After accounting for clerkship order, better OSCE scores were predictive of better National Board of Medical Examiners standardized examination scores (R2Δ = 0.131, p < 0.001) and of better faculty clinical scores (R2Δ = 0.078, p < 0.001). Conclusions: Student assessment by an OSCE provides a reliable and predictive objective assessment of clinical performance in a neurology clerkship. PMID:22855865

  18. Advanced composites for windmills

    NASA Astrophysics Data System (ADS)

    Bourquardez, G.

    A development status assessment is conducted for advanced composite construction techniques for windmill blade structures which, as in the case of composite helicopter rotors, promise greater reliability, longer service life, superior performance, and lower costs. Composites in wind turbine applications must bear aerodynamic, inertial and gravitational loads in complex interaction cycles. Attention is given to large Darrieus-type vertical axis windmills, to which composite construction methods may offer highly effective pitch-control mechanisms, especially in the 'umbrella' configuration.

  19. An integrated control strategy for the composite braking system of an electric vehicle with independently driven axles

    NASA Astrophysics Data System (ADS)

    Sun, Fengchun; Liu, Wei; He, Hongwen; Guo, Hongqiang

    2016-08-01

    For an electric vehicle with independently driven axles, an integrated braking control strategy was proposed to coordinate the regenerative braking and the hydraulic braking. The integrated strategy includes three modes, namely the hybrid composite mode, the parallel composite mode and the pure hydraulic mode. For the hybrid composite mode and the parallel composite mode, the coefficients of distributing the braking force between the hydraulic braking and the two motors' regenerative braking were optimised offline, and the response surfaces related to the driving state parameters were established. Meanwhile, the six-sigma method was applied to deal with the uncertainty problems for reliability. Additionally, the pure hydraulic mode is activated to ensure the braking safety and stability when the predictive failure of the response surfaces occurs. Experimental results under given braking conditions showed that the braking requirements could be well met with high braking stability and energy regeneration rate, and the reliability of the braking strategy was guaranteed on general braking conditions.

  20. Test-retest reliability and practice effects of a rapid screen of mild traumatic brain injury.

    PubMed

    De Monte, Veronica Eileen; Geffen, Gina Malke; Kwapil, Karleigh

    2005-07-01

    Test-retest reliabilities and practice effects of measures from the Rapid Screen of Concussion (RSC), in addition to the Digit Symbol Substitution Test (Digit Symbol), were examined. Twenty five male participants were tested three times; each testing session scheduled a week apart. The test-retest reliability estimates for most measures were reasonably good, ranging from .79 to .97. An exception was the delayed word recall test, which has had a reliability estimate of .66 for the first retest, and .59 for the second retest. Practice effects were evident from Times 1 to 2 on the sentence comprehension and delayed recall subtests of the RSC, Digit Symbol and a composite score. There was also a practice effect of the same magnitude found from Time 2 to Time 3 on Digit Symbol, delayed recall and the composite score. Statistics on measures for both the first and second retest intervals, with associated practice effects, are presented to enable the calculation of reliable change indices (RCI). The RCI may be used to assess any improvement in cognitive functioning after mild Traumatic Brain Injury.

  1. Contact acoustic nonlinearity (CAN)-based continuous monitoring of bolt loosening: Hybrid use of high-order harmonics and spectral sidebands

    NASA Astrophysics Data System (ADS)

    Zhang, Zhen; Liu, Menglong; Liao, Yaozhong; Su, Zhongqing; Xiao, Yi

    2018-03-01

    The significance of evaluating bolt tightness in engineering structures, preferably in a continuous manner, cannot be overemphasized. With hybrid use of high-order harmonics (HOH) and spectral sidebands, a contact acoustic nonlinearity (CAN)-based monitoring framework is developed for detecting bolt loosening and subsequently evaluating the residual torque on a loose bolt. Low-frequency pumping vibration is introduced into the bolted joint to produce a "breathing" effect at the joining interface that modulates the propagation characteristics of a high-frequency probing wave when it traverses the bolt, leading to the generation of HOH and vibro-acoustic nonlinear distortions (manifested as sidebands in the signal spectrum). To gain insight into the mechanism of CAN generation and to correlate the acquired nonlinear responses of a loose joint with the residual torque remaining on the bolt, an analytical model based on micro-contact theory is established. Two types of nonlinear index, respectively exploiting the induced HOH and spectral sidebands, are defined without dependence on excitation intensity and are experimentally demonstrated to be effective in continuously monitoring bolt loosening in both aluminum-aluminum and composite-composite bolted joints. Taking a step further, variation of the index pair is quantitatively associated with the residual torque on a loose bolt. The approach developed provides a reliable method of continuous evaluation of bolt tightness in both composite and metallic joints, regardless of their working conditions, from early awareness of bolt loosening at an embryonic stage to quantitative estimation of residual torque.

  2. Composite structural materials

    NASA Technical Reports Server (NTRS)

    Loewy, Robert G.; Wiberley, Stephen E.

    1988-01-01

    A decade long program to develop critical advanced composite technology in the areas of physical properties, structural concept and analysis, manufacturing, reliability, and life predictions is reviewed. Specific goals are discussed. The status of the chemical vapor deposition effects on carbon fiber properties; inelastic deformation of metal matrix laminates; fatigue damage in fibrous MMC laminates; delamination fracture toughness in thermoplastic matrix composites; and numerical analysis of composite micromechanical behavior are presented.

  3. Reliability-Based Design Optimization of a Composite Airframe Component

    NASA Technical Reports Server (NTRS)

    Pai, Shantaram S.; Coroneos, Rula; Patnaik, Surya N.

    2011-01-01

    A stochastic optimization methodology (SDO) has been developed to design airframe structural components made of metallic and composite materials. The design method accommodates uncertainties in load, strength, and material properties that are defined by distribution functions with mean values and standard deviations. A response parameter, like a failure mode, has become a function of reliability. The primitive variables like thermomechanical loads, material properties, and failure theories, as well as variables like depth of beam or thickness of a membrane, are considered random parameters with specified distribution functions defined by mean values and standard deviations.

  4. Strength and reliability analysis of metal-composite overwrapped pressure vessel

    NASA Astrophysics Data System (ADS)

    Burov, A. E.; Lepikhin, A. M.; Moskvichev, V. V.

    2017-12-01

    Metal-composite overwrapped pressure vessels (MCOPV) have found a wide application in aerospace and aeronautical industries. Such vessels should combine impermeability and high weight efficiency with enhanced long-term safety and durability. To meet these requirements, theoretical and experimental studies on the mechanics of deformation and failure of MCOPV are required. In the paper, the analysis on strength, lifetime and reliability of MCOPV is presented. A high performance of the MCOPV is justified by comparing the calculation results with experiment data obtained on full-scale samples.

  5. Advanced Composite Wind Turbine Blade Design Based on Durability and Damage Tolerance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abumeri, Galib; Abdi, Frank

    2012-02-16

    The objective of the program was to demonstrate and verify Certification-by-Analysis (CBA) capability for wind turbine blades made from advanced lightweight composite materials. The approach integrated durability and damage tolerance analysis with robust design and virtual testing capabilities to deliver superior, durable, low weight, low cost, long life, and reliable wind blade design. The GENOA durability and life prediction software suite was be used as the primary simulation tool. First, a micromechanics-based computational approach was used to assess the durability of composite laminates with ply drop features commonly used in wind turbine applications. Ply drops occur in composite joints andmore » closures of wind turbine blades to reduce skin thicknesses along the blade span. They increase localized stress concentration, which may cause premature delamination failure in composite and reduced fatigue service life. Durability and damage tolerance (D&DT) were evaluated utilizing a multi-scale micro-macro progressive failure analysis (PFA) technique. PFA is finite element based and is capable of detecting all stages of material damage including initiation and propagation of delamination. It assesses multiple failure criteria and includes the effects of manufacturing anomalies (i.e., void, fiber waviness). Two different approaches have been used within PFA. The first approach is Virtual Crack Closure Technique (VCCT) PFA while the second one is strength-based. Constituent stiffness and strength properties for glass and carbon based material systems were reverse engineered for use in D&DT evaluation of coupons with ply drops under static loading. Lamina and laminate properties calculated using manufacturing and composite architecture details matched closely published test data. Similarly, resin properties were determined for fatigue life calculation. The simulation not only reproduced static strength and fatigue life as observed in the test, it also showed composite damage and fracture modes that resemble those reported in the tests. The results show that computational simulation can be relied on to enhance the design of tapered composite structures such as the ones used in turbine wind blades. A computational simulation for durability, damage tolerance (D&DT) and reliability of composite wind turbine blade structures in presence of uncertainties in material properties was performed. A composite turbine blade was first assessed with finite element based multi-scale progressive failure analysis to determine failure modes and locations as well as the fracture load. D&DT analyses were then validated with static test performed at Sandia National Laboratories. The work was followed by detailed weight analysis to identify contribution of various materials to the overall weight of the blade. The methodology ensured that certain types of failure modes, such as delamination progression, are contained to reduce risk to the structure. Probabilistic analysis indicated that composite shear strength has a great influence on the blade ultimate load under static loading. Weight was reduced by 12% with robust design without loss in reliability or D&DT. Structural benefits obtained with the use of enhanced matrix properties through nanoparticles infusion were also assessed. Thin unidirectional fiberglass layers enriched with silica nanoparticles were applied to the outer surfaces of a wind blade to improve its overall structural performance and durability. The wind blade was a 9-meter prototype structure manufactured and tested subject to three saddle static loading at Sandia National Laboratory (SNL). The blade manufacturing did not include the use of any nano-material. With silica nanoparticles in glass composite applied to the exterior surfaces of the blade, the durability and damage tolerance (D&DT) results from multi-scale PFA showed an increase in ultimate load of the blade by 9.2% as compared to baseline structural performance (without nano). The use of nanoparticles lead to a delay in the onset of delamination. Load-displacement relationships obtained from testing of the blade with baseline neat material were compared to the ones from analytical simulation using neat resin and using silica nanoparticles in the resin. Multi-scale PFA results for the neat material construction matched closely those from test for both load displacement and location and type of damage and failure. AlphaSTAR demonstrated that wind blade structures made from advanced composite materials can be certified with multi-scale progressive failure analysis by following building block verification approach.« less

  6. Disbond detection with piezoelectric wafer active sensors in RC structures strengthened with FRP composite overlays

    NASA Astrophysics Data System (ADS)

    Giurgiutiu, Victor; Harries, Kent; Petrou, Michael; Bost, Joel; Quattlebaum, Josh B.

    2003-12-01

    The capability of embedded piezoelectric wafer active sensors (PWAS) to perform in-situ nondestructive evaluation (NDE) for structural health monitoring (SHM) of reinforced concrete (RC) structures strengthened with fiber reinforced polymer (FRP) composite overlays is explored. First, the disbond detection method were developed on coupon specimens consisting of concrete blocks covered with an FRP composite layer. It was found that the presence of a disbond crack drastically changes the electromechanical (E/M) impedance spectrum measured at the PWAS terminals. The spectral changes depend on the distance between the PWAS and the crack tip. Second, large scale experiments were conducted on a RC beam strengthened with carbon fiber reinforced polymer (CFRP) composite overlay. The beam was subject to an accelerated fatigue load regime in a three-point bending configuration up to a total of 807,415 cycles. During these fatigue tests, the CFRP overlay experienced disbonding beginning at about 500,000 cycles. The PWAS were able to detect the disbonding before it could be reliably seen by visual inspection. Good correlation between the PWAS readings and the position and extent of disbond damage was observed. These preliminary results demonstrate the potential of PWAS technology for SHM of RC structures strengthened with FRP composite overlays.

  7. Evaluation of morphology and size of cracks of the Interfacial Transition Zone (ITZ) in concrete containing fly ash (FA).

    PubMed

    Golewski, Grzegorz Ludwik

    2018-06-07

    Interfacial Transition Zone (ITZ) of coarse aggregate cement matrix is commonly regarded as the weakest element of concrete. In this phase - the first cracks in the material are initiated, and the process of destruction of the composite begins. An improvement of the ITZ properties are positively influenced by the mineral additives used for the composite. One of such a substitute for a binder is, potentially hazardous industrial waste, siliceous fly ash (FA). In this paper the ITZ between aggregate and cement paste in concretes containing FA is considered. The paper presents the results of tests on the effect of the addition of FA in the amount of: 0, 20 and 30% by weight of cement on morphology and size of cracks of the ITZ in composites. In matured concretes the smallest cracks occur in composite with the 20% FA additive. It can be concluded that composites with 20% addition of FA are characterized by low permeability and therefore high durability. The results of tests carried out can be helpful in obtaining concrete with the highest possible: strength, durability and reliability of operation. Moreover, such procedures also cause a restriction storage of hazardous materials, i.e. FA - by 160 million tons per year. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Olympic Scoring of English Compositions

    ERIC Educational Resources Information Center

    Follman, John; Panther, Edward

    1974-01-01

    Examines empirically the efficacy of utilizing Olympic diving and gymnastic scoring systems for grading graduate students' English compositions. Results indicated that such scoring rules do not produce ratings different in reliability or in level from conventional letter grades. (ED)

  9. The quality and suitability of written educational materials for patients*.

    PubMed

    Demir, Fatma; Ozsaker, Esma; Ilce, Arzu Ozcan

    2008-01-01

    In this study, the quality and suitability of written educational materials being used for the education of patients in surgical departments of hospitals were studied. In the literature, it is stated that most of the educational materials for patients are not suitable from the aspects of contents, structure, design, composition and language. In this descriptive type study, which was carried out between March and May 2006, 59 examples of written educational material used for patient education at 138 surgical clinics were evaluated for quality and suitability. The written educational materials obtained were evaluated independently by researchers from the aspect of quality and suitability. The DISCERN measuring instrument was used in the evaluation of the reliability of the written educational materials and the Evaluation of the Suitability of Written Materials form was used in the evaluation of suitability. It was determined that the educational materials received low scores for reliability and information quality. It was determined that the total scores for the written educational materials were average for suitability. It was determined that there were no written educational materials in more than half of the surgical units included in the study. It was also found that the educational materials had serious deficiencies. This study showed that there was no adequate written patient educational material at the clinics. This deficiency in written educational materials could be eliminated by having them prepared by health professionals in accordance with guidebooks and taking the target group into account.

  10. Effects of measurement method and transcript availability on inexperienced raters' stuttering frequency scores.

    PubMed

    Chakraborty, Nalanda; Logan, Kenneth J

    To examine the effects of measurement method and transcript availability on the accuracy, reliability, and efficiency of inexperienced raters' stuttering frequency measurements. 44 adults, all inexperienced at evaluating stuttered speech, underwent 20 min of preliminary training in stuttering measurement and then analyzed a series of sentences, with and without access to transcripts of sentence stimuli, using either a syllable-based analysis (SBA) or an utterance-based analysis (UBA). Participants' analyses were compared between groups and to a composite analysis from two experienced evaluators. Stuttering frequency scores from the SBA and UBA groups differed significantly from the experienced evaluators' scores; however, UBA scores were significantly closer to the experienced evaluators' scores and were completed significantly faster than the SBA scores. Transcript availability facilitated scoring accuracy and efficiency in both groups. The internal reliability of stuttering frequency scores was acceptable for the SBA and UBA groups; however, the SBA group demonstrated only modest point-by-point agreement with ratings from the experienced evaluators. Given its accuracy and efficiency advantages over syllable-based analysis, utterance-based fluency analysis appears to be an appropriate context for introducing stuttering frequency measurement to raters who have limited experience in stuttering measurement. To address accuracy gaps between experienced and inexperienced raters, however, use of either analysis must be supplemented with training activities that expose inexperienced raters to the decision-making processes used by experienced raters when identifying stuttered syllables. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Composition measurement of epitaxial Sc x Ga1-x N films

    NASA Astrophysics Data System (ADS)

    Tsui, H. C. L.; Goff, L. E.; Barradas, N. P.; Alves, E.; Pereira, S.; Palgrave, R. G.; Davies, R. J.; Beere, H. E.; Farrer, I.; Ritchie, D. A.; Moram, M. A.

    2016-06-01

    Four different methods for measuring the compositions of epitaxial Sc x Ga1-x N films were assessed and compared to determine which was the most reliable and accurate. The compositions of epitaxial Sc x Ga1-x N films with 0 ≤ x ≤ 0.26 were measured directly using Rutherford backscattering (RBS) and x-ray photoelectron spectroscopy (XPS), and indirectly using c lattice parameter measurements from x-ray diffraction and c/a ratio measurements from electron diffraction patterns. RBS measurements were taken as a standard reference. XPS was found to underestimate the Sc content, whereas c lattice parameter and c/a ratio were not reliable for composition determination due to the unknown degree of strain relaxation in the film. However, the Sc flux used during growth was found to relate linearly with x and could be used to estimate the Sc content.

  12. Fifteen-Minute Comprehensive Alcohol Risk Survey: Reliability and Validity Across American Indian and White Adolescents

    PubMed Central

    Komro, Kelli A; Livingston, Melvin D; Kominsky, Terrence K; Livingston, Bethany J; Garrett, Brady A; Molina, Mildred Maldonado; Boyd, Misty L

    2015-01-01

    Objective: American Indians (AIs) suffer from significant alcohol-related health disparities, and increased risk begins early. This study examined the reliability and validity of measures to be used in a preventive intervention trial. Reliability and validity across racial/ethnic subgroups are crucial to evaluate intervention effectiveness and promote culturally appropriate evidence-based practice. Method: To assess reliability and validity, we used three baseline surveys of high school students participating in a preventive intervention trial within the jurisdictional service area of the Cherokee Nation in northeastern Oklahoma. The 15-minute alcohol risk survey included 16 multi-item scales and one composite score measuring key proximal, primary, and moderating variables. Forty-four percent of the students indicated that they were AI (of whom 82% were Cherokee), including 23% who reported being AI only (n = 435) and 18% both AI and White (n = 352). Forty-seven percent reported being White only (n = 901). Results: Scales were adequately reliable for the full sample and across race/ethnicity defined by AI, AI/White, and White subgroups. Among the full sample, all scales had acceptable internal consistency, with minor variation across race/ethnicity. All scales had extensive to exemplary test–retest reliability and showed minimal variation across race/ethnicity. The eight proximal and two primary outcome scales were each significantly associated with the frequency of alcohol use during the past month in both the cross-sectional and the longitudinal models, providing support for both criterion validity and predictive validity. For most scales, interpretation of the strength of association and statistical significance did not differ between the racial/ethnic subgroups. Conclusions: The results support the reliability and validity of scales of a brief questionnaire measuring risk and protective factors for alcohol use among AI adolescents, primarily members of the Cherokee Nation. PMID:25486402

  13. Reliability and Creep/Fatigue Analysis of a CMC Component

    NASA Technical Reports Server (NTRS)

    Murthy, Pappu L. N.; Mital, Subodh K.; Gyekenyesi, John Z.; Gyekenyesi, John P.

    2007-01-01

    High temperature ceramic matrix composites (CMC) are being explored as viable candidate materials for hot section gas turbine components. These advanced composites can potentially lead to reduced weight and enable higher operating temperatures requiring less cooling; thus leading to increased engine efficiencies. There is a need for convenient design tools that can accommodate various loading conditions and material data with their associated uncertainties to estimate the minimum predicted life as well as the failure probabilities of a structural component. This paper presents a review of the life prediction and probabilistic analyses performed for a CMC turbine stator vane. A computer code, NASALife, is used to predict the life of a 2-D woven silicon carbide fiber reinforced silicon carbide matrix (SiC/SiC) turbine stator vane due to a mission cycle which induces low cycle fatigue and creep. The output from this program includes damage from creep loading, damage due to cyclic loading and the combined damage due to the given loading cycle. Results indicate that the trends predicted by NASALife are as expected for the loading conditions used for this study. In addition, a combination of woven composite micromechanics, finite element structural analysis and Fast Probability Integration (FPI) techniques has been used to evaluate the maximum stress and its probabilistic distribution in a CMC turbine stator vane. Input variables causing scatter are identified and ranked based upon their sensitivity magnitude. Results indicate that reducing the scatter in proportional limit strength of the vane material has the greatest effect in improving the overall reliability of the CMC vane.

  14. Psychometric characteristics of the MATRICS Consensus Cognitive Battery in a large pooled cohort of stable schizophrenia patients.

    PubMed

    Georgiades, Anastasia; Davis, Vicki G; Atkins, Alexandra S; Khan, Anzalee; Walker, Trina W; Loebel, Antony; Haig, George; Hilt, Dana C; Dunayevich, Eduardo; Umbricht, Daniel; Sand, Michael; Keefe, Richard S E

    2017-12-01

    The MATRICS Consensus Cognitive Battery (MCCB) was developed to assess cognitive treatment effects in schizophrenia clinical trials, and is considered the FDA gold standard outcome measure for that purpose. The aim of the present study was to establish pre-treatment psychometric characteristics of the MCCB in a large pooled sample. The dataset included 2616 stable schizophrenia patients enrolled in 15 different clinical trials between 2007 and 2016 within the United States (94%) and Canada (6%). The MCCB was administered twice prior to the initiation of treatment in 1908 patients. Test-retest reliability and practice effects of the cognitive composite score, the neurocognitive composite score, which excludes the domain Social Cognition, and the subtests/domains were examined using Intra-Class Correlations (ICC) and Cohen's d. Simulated regression models explored which domains explained the greatest portion of variance in composite scores. Test-retest reliability was high (ICC=0.88) for both composite scores. Practice effects were small for the cognitive (d=0.15) and neurocognitive (d=0.17) composites. Simulated bootstrap regression analyses revealed that 3 of the 7 domains explained 86% of the variance for both composite scores. The domains that entered most frequently in the top 3 positions of the regression models were Speed of Processing, Working Memory, and Visual Learning. Findings provide definitive psychometric characteristics and a benchmark comparison for clinical trials using the MCCB. The test-retest reliability of the MCCB composite scores is considered excellent and the learning effects are small, fulfilling two of the key criteria for outcome measures in cognition clinical trials. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Cultural competency assessment tool for hospitals: Evaluating hospitals’ adherence to the culturally and linguistically appropriate services standards

    PubMed Central

    Weech-Maldonado, Robert; Dreachslin, Janice L.; Brown, Julie; Pradhan, Rohit; Rubin, Kelly L.; Schiller, Cameron; Hays, Ron D.

    2016-01-01

    Background The U.S. national standards for culturally and linguistically appropriate services (CLAS) in health care provide guidelines on policies and practices aimed at developing culturally competent systems of care. The Cultural Competency Assessment Tool for Hospitals (CCATH) was developed as an organizational tool to assess adherence to the CLAS standards. Purposes First, we describe the development of the CCATH and estimate the reliability and validity of the CCATH measures. Second, we discuss the managerial implications of the CCATH as an organizational tool to assess cultural competency. Methodology/Approach We pilot tested an initial draft of the CCATH, revised it based on a focus group and cognitive interviews, and then administered it in a field test with a sample of California hospitals. The reliability and validity of the CCATH were evaluated using factor analysis, analysis of variance, and Cronbach’s alphas. Findings Exploratory and confirmatory factor analyses identified 12 CCATH composites: leadership and strategic planning, data collection on inpatient population, data collection on service area, performance management systems and quality improvement, human resources practices, diversity training, community representation, availability of interpreter services, interpreter services policies, quality of interpreter services, translation of written materials, and clinical cultural competency practices. All the CCATH scales had internal consistency reliability of .65 or above, and the reliability was .70 or above for 9 of the 12 scales. Analysis of variance results showed that not-for-profit hospitals have higher CCATH scores than for-profit hospitals in five CCATH scales and higher CCATH scores than government hospitals in two CCATH scales. Practice Implications The CCATH showed adequate psychometric properties. Managers and policy makers can use the CCATH as a tool to evaluate hospital performance in cultural competency and identify and target improvements in hospital policies and practices that undergird the provision of CLAS. PMID:21934511

  16. Evaluation of selected thermal control coatings for long-life space structures

    NASA Technical Reports Server (NTRS)

    Teichman, Louis A.; Slemp, Wayne S.; Witte, William G., Jr.

    1992-01-01

    Graphite-reinforced resin matrix composites are being considered for spacecraft structural applications because of their light weight, high stiffness, and lower thermal expansion. Thin protective coatings with stable optical properties and the proper ratio of solar absorption (alpha sub s) to thermal emittance (epsilon) minimize orbital thermal extremes and protect these materials against space environment degradation. Sputtered coatings applied directly to graphite/epoxy composite surfaces and anodized coatings applied to thin aluminum foil were studied for use both as an atomic oxygen barrier and as thermal control coatings. Additional effort was made to develop nickel-based coatings which could be applied directly to composites. These coating systems were selected because their inherent tenacity made them potentially more reliable than commercial white paints for long-life space missions. Results indicate that anodized aluminum foil coatings are suitable for tubular and flat composite structures on large platforms in low Earth orbit. Anodized foil provides protection against some elements of the natural space environment (atomic oxygen, ultraviolet, and particulate radiation) and offers a broad range of tailored alpha sub s/epsilon. The foil is readily available and can be produced in large quantities, while the anodizing process is a routine commercial technique.

  17. ICAN: A versatile code for predicting composite properties

    NASA Technical Reports Server (NTRS)

    Ginty, C. A.; Chamis, C. C.

    1986-01-01

    The Integrated Composites ANalyzer (ICAN), a stand-alone computer code, incorporates micromechanics equations and laminate theory to analyze/design multilayered fiber composite structures. Procedures for both the implementation of new data in ICAN and the selection of appropriate measured data are summarized for: (1) composite systems subject to severe thermal environments; (2) woven fabric/cloth composites; and (3) the selection of new composite systems including those made from high strain-to-fracture fibers. The comparisons demonstrate the versatility of ICAN as a reliable method for determining composite properties suitable for preliminary design.

  18. Reproducibility of ZrO2-based freeze casting for biomaterials.

    PubMed

    Naleway, Steven E; Fickas, Kate C; Maker, Yajur N; Meyers, Marc A; McKittrick, Joanna

    2016-04-01

    The processing technique of freeze casting has been intensely researched for its potential to create porous scaffold and infiltrated composite materials for biomedical implants and structural materials. However, in order for this technique to be employed medically or commercially, it must be able to reliably produce materials in great quantities with similar microstructures and properties. Here we investigate the reproducibility of the freeze casting process by independently fabricating three sets of eight ZrO2-epoxy composite scaffolds with the same processing conditions but varying solid loading (10, 15 and 20 vol.%). Statistical analyses (One-way ANOVA and Tukey's HSD tests) run upon measurements of the microstructural dimensions of these composite scaffold sets show that, while the majority of microstructures are similar, in all cases the composite scaffolds display statistically significant variability. In addition, composite scaffolds where mechanically compressed and statistically analyzed. Similar to the microstructures, almost all of their resultant properties displayed significant variability though most composite scaffolds were similar. These results suggest that additional research to improve control of the freeze casting technique is required before scaffolds and composite scaffolds can reliably be reproduced for commercial or medical applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Ceramic Technology Project semiannual progress report, October 1992--March 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, D.R.

    1993-09-01

    This project was developed to meet the ceramic technology requirements of the OTS`s automotive technology programs. Although progress has been made in developing reliable structural ceramics, further work is needed to reduce cost. The work described in this report is organized according to the following work breakdown structure project elements: Materials and processing (monolithics [Si nitride, carbide], ceramic composites, thermal and wear coatings, joining, cost effective ceramic machining), materials design methodology (contact interfaces, new concepts), data base and life prediction (structural qualification, time-dependent behavior, environmental effects, fracture mechanics, nondestructive evaluation development), and technology transfer.

  20. FEAMAC-CARES Software Coupling Development Effort for CMC Stochastic-Strength-Based Damage Simulation

    NASA Technical Reports Server (NTRS)

    Nemeth, Noel N.; Bednarcyk, Brett A.; Pineda, Evan; Arnold, Steven; Mital, Subodh; Murthy, Pappu; Walton, Owen

    2015-01-01

    Reported here is a coupling of two NASA developed codes: CARES (Ceramics Analysis and Reliability Evaluation of Structures) with the MACGMC composite material analysis code. The resulting code is called FEAMACCARES and is constructed as an Abaqus finite element analysis UMAT (user defined material). Here we describe the FEAMACCARES code and an example problem (taken from the open literature) of a laminated CMC in off-axis loading is shown. FEAMACCARES performs stochastic-strength-based damage simulation response of a CMC under multiaxial loading using elastic stiffness reduction of the failed elements.

  1. Reliability and Confidence Interval Analysis of a CMC Turbine Stator Vane

    NASA Technical Reports Server (NTRS)

    Murthy, Pappu L. N.; Gyekenyesi, John P.; Mital, Subodh K.

    2008-01-01

    High temperature ceramic matrix composites (CMC) are being explored as viable candidate materials for hot section gas turbine components. These advanced composites can potentially lead to reduced weight, enable higher operating temperatures requiring less cooling and thus leading to increased engine efficiencies. However, these materials are brittle and show degradation with time at high operating temperatures due to creep as well as cyclic mechanical and thermal loads. In addition, these materials are heterogeneous in their make-up and various factors affect their properties in a specific design environment. Most of these advanced composites involve two- and three-dimensional fiber architectures and require a complex multi-step high temperature processing. Since there are uncertainties associated with each of these in addition to the variability in the constituent material properties, the observed behavior of composite materials exhibits scatter. Traditional material failure analyses employing a deterministic approach, where failure is assumed to occur when some allowable stress level or equivalent stress is exceeded, are not adequate for brittle material component design. Such phenomenological failure theories are reasonably successful when applied to ductile materials such as metals. Analysis of failure in structural components is governed by the observed scatter in strength, stiffness and loading conditions. In such situations, statistical design approaches must be used. Accounting for these phenomena requires a change in philosophy on the design engineer s part that leads to a reduced focus on the use of safety factors in favor of reliability analyses. The reliability approach demands that the design engineer must tolerate a finite risk of unacceptable performance. This risk of unacceptable performance is identified as a component's probability of failure (or alternatively, component reliability). The primary concern of the engineer is minimizing this risk in an economical manner. The methods to accurately determine the service life of an engine component with associated variability have become increasingly difficult. This results, in part, from the complex missions which are now routinely considered during the design process. These missions include large variations of multi-axial stresses and temperatures experienced by critical engine parts. There is a need for a convenient design tool that can accommodate various loading conditions induced by engine operating environments, and material data with their associated uncertainties to estimate the minimum predicted life of a structural component. A probabilistic composite micromechanics technique in combination with woven composite micromechanics, structural analysis and Fast Probability Integration (FPI) techniques has been used to evaluate the maximum stress and its probabilistic distribution in a CMC turbine stator vane. Furthermore, input variables causing scatter are identified and ranked based upon their sensitivity magnitude. Since the measured data for the ceramic matrix composite properties is very limited, obtaining a probabilistic distribution with their corresponding parameters is difficult. In case of limited data, confidence bounds are essential to quantify the uncertainty associated with the distribution. Usually 90 and 95% confidence intervals are computed for material properties. Failure properties are then computed with the confidence bounds. Best estimates and the confidence bounds on the best estimate of the cumulative probability function for R-S (strength - stress) are plotted. The methodologies and the results from these analyses will be discussed in the presentation.

  2. Development and reliability testing of the Worksite and Energy Balance Survey.

    PubMed

    Hoehner, Christine M; Budd, Elizabeth L; Marx, Christine M; Dodson, Elizabeth A; Brownson, Ross C

    2013-01-01

    Worksites represent important venues for health promotion. Development of psychometrically sound measures of worksite environments and policy supports for physical activity and healthy eating are needed for use in public health research and practice. Assess the test-retest reliability of the Worksite and Energy Balance Survey (WEBS), a self-report instrument for assessing perceptions of worksite supports for physical activity and healthy eating. The WEBS included items adapted from existing surveys or new items on the basis of a review of the literature and expert review. Cognitive interviews among 12 individuals were used to test the clarity of items and further refine the instrument. A targeted random-digit-dial telephone survey was administered on 2 occasions to assess test-retest reliability (mean days between time periods = 8; minimum = 5; maximum = 14). Five Missouri census tracts that varied by racial-ethnic composition and walkability. Respondents included 104 employed adults (67% white, 64% women, mean age = 48.6 years). Sixty-three percent were employed at worksites with less than 100 employees, approximately one-third supervised other people, and the majority worked a regular daytime shift (75%). Test-retest reliability was assessed using Spearman correlations for continuous variables, Cohen's κ statistics for nonordinal categorical variables, and 1-way random intraclass correlation coefficients for ordinal categorical variables. Test-retest coefficients ranged from 0.41 to 0.97, with 80% of items having reliability coefficients of more than 0.6. Items that assessed participation in or use of worksite programs/facilities tended to have lower reliability. Reliability of some items varied by gender, obesity status, and worksite size. Test-retest reliability and internal consistency for the 5 scales ranged from 0.84 to 0.94 and 0.63 to 0.84, respectively. The WEBS items and scales exhibited sound test-retest reliability and may be useful for research and surveillance. Further evaluation is needed to document the validity of the WEBS and associations with energy balance outcomes.

  3. Time-saving design of experiment protocol for optimization of LC-MS data processing in metabolomic approaches.

    PubMed

    Zheng, Hong; Clausen, Morten Rahr; Dalsgaard, Trine Kastrup; Mortensen, Grith; Bertram, Hanne Christine

    2013-08-06

    We describe a time-saving protocol for the processing of LC-MS-based metabolomics data by optimizing parameter settings in XCMS and threshold settings for removing noisy and low-intensity peaks using design of experiment (DoE) approaches including Plackett-Burman design (PBD) for screening and central composite design (CCD) for optimization. A reliability index, which is based on evaluation of the linear response to a dilution series, was used as a parameter for the assessment of data quality. After identifying the significant parameters in the XCMS software by PBD, CCD was applied to determine their values by maximizing the reliability and group indexes. Optimal settings by DoE resulted in improvements of 19.4% and 54.7% in the reliability index for a standard mixture and human urine, respectively, as compared with the default setting, and a total of 38 h was required to complete the optimization. Moreover, threshold settings were optimized by using CCD for further improvement. The approach combining optimal parameter setting and the threshold method improved the reliability index about 9.5 times for a standards mixture and 14.5 times for human urine data, which required a total of 41 h. Validation results also showed improvements in the reliability index of about 5-7 times even for urine samples from different subjects. It is concluded that the proposed methodology can be used as a time-saving approach for improving the processing of LC-MS-based metabolomics data.

  4. Optimization Testbed Cometboards Extended into Stochastic Domain

    NASA Technical Reports Server (NTRS)

    Patnaik, Surya N.; Pai, Shantaram S.; Coroneos, Rula M.; Patnaik, Surya N.

    2010-01-01

    COMparative Evaluation Testbed of Optimization and Analysis Routines for the Design of Structures (CometBoards) is a multidisciplinary design optimization software. It was originally developed for deterministic calculation. It has now been extended into the stochastic domain for structural design problems. For deterministic problems, CometBoards is introduced through its subproblem solution strategy as well as the approximation concept in optimization. In the stochastic domain, a design is formulated as a function of the risk or reliability. Optimum solution including the weight of a structure, is also obtained as a function of reliability. Weight versus reliability traced out an inverted-S-shaped graph. The center of the graph corresponded to 50 percent probability of success, or one failure in two samples. A heavy design with weight approaching infinity could be produced for a near-zero rate of failure that corresponded to unity for reliability. Weight can be reduced to a small value for the most failure-prone design with a compromised reliability approaching zero. The stochastic design optimization (SDO) capability for an industrial problem was obtained by combining three codes: MSC/Nastran code was the deterministic analysis tool, fast probabilistic integrator, or the FPI module of the NESSUS software, was the probabilistic calculator, and CometBoards became the optimizer. The SDO capability requires a finite element structural model, a material model, a load model, and a design model. The stochastic optimization concept is illustrated considering an academic example and a real-life airframe component made of metallic and composite materials.

  5. Sulphured Polyacrylonitrile Composite Analysed by in operando UV-Visible Spectroscopy and 4-electrode Swagelok Cell.

    PubMed

    Dominko, Robert; Patel, Manu U M; Bele, Marjan; Pejovnik, Stane

    2016-01-01

    The electrochemical characteristics of sulfurized polyacrylonitrile composite (PAN/S) cathodes were compared with the commonly used carbon/S-based composite material. The difference in the working mechanism of these composites was examined. Analytical investigations were performed on both kinds of cathode electrode composites by using two reliable analytical techniques, in-situ UV-Visible spectroscopy and a four-electrode Swagelok cell. This study differentiates the working mechanisms of PAN/S composites from conventional elemental sulphur/carbon composite and also sheds light on factors that could be responsible for capacity fading in the case of PAN/S composites.

  6. Creep and creep-recovery of a thermoplastic resin and composite

    NASA Technical Reports Server (NTRS)

    Hiel, Clem

    1988-01-01

    The database on advanced thermoplastic composites, which is currently available to industry, contains little data on the creep and viscoelastic behavior. This behavior is nevertheless considered important, particularly for extended-service reliability in structural applications. The creep deformation of a specific thermoplastic resin and composite is reviewed. The problem to relate the data obtained on the resin to the data obtained on the composite is discussed.

  7. Method for Selective Cleaning of Mold Release from Composite Honeycomb Surfaces

    NASA Technical Reports Server (NTRS)

    Pugel, Diane

    2011-01-01

    Honeycomb structures are commonly employed as load- and force-bearing structures as they are structurally strong and lightweight. Manufacturing processes for heat-molded composite honeycomb structures commence with the placement of pre-impregnated composite layups over metal mandrels. To prevent permanent bonding between the composite layup and the metal mandrels, an agent, known as a mold release agent, is used. Mold release agents allow the molded composite material to be removed from mandrels after a heat-forming process. Without a specific removal process, mold release agents may continue to adhere to the surface of the composite material, thereby affecting the bonding of other materials that may come into contact with the composite surface in later stages of processing A constituent common to commercially available household cleaning agents is employed for the removal of mold release agents common to the manufacturing of heat-formed composite materials. The reliability of the solvent has been proven by the longevity and reliability of commercial household cleaners. At the time of this reporting, no one has attempted using constituent for this purpose. The material to be cleaned is immersed in the solution, vertically removed so that the solution is allowed to drain along cell walls and into a solvent bath, and then placed on a compressed airflow table for drying.

  8. RELIABLE COMPUTATION OF HOMOGENEOUS AZEOTROPES. (R824731)

    EPA Science Inventory

    Abstract

    It is important to determine the existence and composition of homogeneous azeotropes in the analysis of phase behavior and in the synthesis and design of separation systems, from both theoretical and practical standpoints. A new method for reliably locating an...

  9. A study on reliability of power customer in distribution network

    NASA Astrophysics Data System (ADS)

    Liu, Liyuan; Ouyang, Sen; Chen, Danling; Ma, Shaohua; Wang, Xin

    2017-05-01

    The existing power supply reliability index system is oriented to power system without considering actual electricity availability in customer side. In addition, it is unable to reflect outage or customer’s equipment shutdown caused by instantaneous interruption and power quality problem. This paper thus makes a systematic study on reliability of power customer. By comparing with power supply reliability, reliability of power customer is defined and extracted its evaluation requirements. An indexes system, consisting of seven customer indexes and two contrast indexes, are designed to describe reliability of power customer from continuity and availability. In order to comprehensively and quantitatively evaluate reliability of power customer in distribution networks, reliability evaluation method is proposed based on improved entropy method and the punishment weighting principle. Practical application has proved that reliability index system and evaluation method for power customer is reasonable and effective.

  10. Numerical study of the effect of the shape of the phase diagram on the eutectic freezing temperature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ode, M.; Shimono, M.; Sasajima, N.

    2013-09-11

    To evaluate the reliability of metal-carbon eutectic systems as fixed points for the next generation of high-temperature standards the effect of thermodynamic properties related to the shape of eutectic phase diagram on the freezing temperature is investigated within the context of the numerical multi-phase-field model. The partition coefficient and liquidus slopes of the two solids involved in the eutectic reaction are varied deliberately and independently. The difference between the eutectic temperature and the freezing temperature is determined in dependence of the solid/liquid (s/l) interface shape and concentration. Where appropriate reference is made to the Jackson-Hunt analytical theory. It is shownmore » that there are mainly two typical conditions to decrease the undercooling: 1) a small liquidus slope and 2) the associated difference between the eutectic composition and the liquid composition during solidification.« less

  11. Uranium mobility across annual growth rings in three deciduous tree species

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McHugh, Kelly C.; Widom, Elisabeth; Spitz, Henry B.

    Black walnut (Juglans nigra), slippery elm (Ulmus rubra), and white ash (Fraxinus americana) trees were evaluated as potential archives of past uranium (U) contamination. Like other metals, U mobility in annual growth rings of trees is potentially dependent on the tree species. Uranium concentrations and isotopic compositions (masses 234, 235, 236, and 238) were analyzed by thermal ionization mass spectrometry to test the efficacy of using tree rings to retroactively monitor U pollution from the FFMPC, a U purification facility operating from 1951 to 1989. This study found non-natural U (depleted U and detectable 236U) in growth rings of allmore » three tree species that pre-dated the start of operations at FFMPC and compositional trends that did not correspond with known contamination events. Therefore, the annual growth rings of these tree species cannot be used to reliably monitor the chronology of U contamination.« less

  12. Three-dimensional surface imaging system for assessing human obesity

    NASA Astrophysics Data System (ADS)

    Xu, Bugao; Yu, Wurong; Yao, Ming; Pepper, M. Reese; Freeland-Graves, Jeanne H.

    2009-10-01

    The increasing prevalence of obesity suggests a need to develop a convenient, reliable, and economical tool for assessment of this condition. Three-dimensional (3-D) body surface imaging has emerged as an exciting technology for the estimation of body composition. We present a new 3-D body imaging system, which is designed for enhanced portability, affordability, and functionality. In this system, stereo vision technology is used to satisfy the requirement for a simple hardware setup and fast image acquisition. The portability of the system is created via a two-stand configuration, and the accuracy of body volume measurements is improved by customizing stereo matching and surface reconstruction algorithms that target specific problems in 3-D body imaging. Body measurement functions dedicated to body composition assessment also are developed. The overall performance of the system is evaluated in human subjects by comparison to other conventional anthropometric methods, as well as air displacement plethysmography, for body fat assessment.

  13. A 3D surface imaging system for assessing human obesity

    NASA Astrophysics Data System (ADS)

    Xu, B.; Yu, W.; Yao, M.; Yao, X.; Li, Q.; Pepper, M. R.; Freeland-Graves, J. H.

    2009-08-01

    The increasing prevalence of obesity suggests a need to develop a convenient, reliable and economical tool for assessment of this condition. Three-dimensional (3D) body surface imaging has emerged as an exciting technology for estimation of body composition. This paper presents a new 3D body imaging system, which was designed for enhanced portability, affordability, and functionality. In this system, stereo vision technology was used to satisfy the requirements for a simple hardware setup and fast image acquisitions. The portability of the system was created via a two-stand configuration, and the accuracy of body volume measurements was improved by customizing stereo matching and surface reconstruction algorithms that target specific problems in 3D body imaging. Body measurement functions dedicated to body composition assessment also were developed. The overall performance of the system was evaluated in human subjects by comparison to other conventional anthropometric methods, as well as air displacement plethysmography, for body fat assessment.

  14. Uranium mobility across annual growth rings in three deciduous tree species.

    PubMed

    McHugh, Kelly C; Widom, Elisabeth; Spitz, Henry B; Wiles, Gregory C; Glover, Sam E

    2018-02-01

    Black walnut (Juglans nigra), slippery elm (Ulmus rubra), and white ash (Fraxinus americana) trees were evaluated as potential archives of past uranium (U) contamination. Like other metals, U mobility in annual growth rings of trees is dependent on the tree species. Uranium concentrations and isotopic compositions (masses 234, 235, 236, and 238) were analyzed by thermal ionization mass spectrometry to test the efficacy of using tree rings to retroactively monitor U pollution from the FFMPC, a U purification facility operating from 1951 to 1989. This study found non-natural U (depleted U and detectable 236 U) in growth rings of all three tree species that pre-dated the start of operations at FFMPC and compositional trends that did not correspond with known contamination events. Therefore, the annual growth rings of these tree species cannot be used to reliably monitor the chronology of U contamination. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Evaluating symptom outcomes in gastroparesis clinical trials: validity and responsiveness of the Gastroparesis Cardinal Symptom Index-Daily Diary (GCSI-DD).

    PubMed

    Revicki, D A; Camilleri, M; Kuo, B; Szarka, L A; McCormack, J; Parkman, H P

    2012-05-01

    Patient-reported symptom scales are needed to evaluate treatments for gastroparesis. The Gastroparesis Cardinal Symptom Index-Daily Diary (GCSI-DD) was developed to assess daily symptoms of gastroparesis. This study evaluated the validity and responsiveness of the GCSI-DD in patients with gastroparesis. Symptomatic patients were started with a new treatment for gastroparesis. Patients completed the GCSI-DD each evening during a baseline week and for 8 weeks of treatment. Responders were defined based on patient and clinician global rating of change. Minimal important differences (MID) were estimated based on baseline to 4 week changes in symptoms scores for small improvements. Of 69 patients participating, 46 had idiopathic, 19 diabetic, and four postfundoplication gastroparesis. Excellent test-retest reliability was seen for GCSI-DD scores, and there were significant correlations between GCSI-DD scores and clinician ratings of symptom severity. Responders to treatment reported improvements in nausea [effect size (ES) = 0.42, P < 0.001], postprandial fullness, ES = 0.83, P < 0.001), bloating (ES = 0.34, P < 0.001), early satiety (ES = 0.53, P < 0.001), but lower responses for upper abdominal pain (ES = 0.29), and vomiting (ES = 0.22; P = 0.119). MIDs were 0.55 for nausea, 0.97 for excessive fullness, 0.63 for bloating, 0.77 for postprandial fullness, and 0.30 for abdominal pain. A composite score of four symptoms (Composite-1; nausea, bloating, excessive fullness, postprandial fullness) had ES of 0.61 and MID of 0.73. Composite-2 score (nausea, early satiety, bloating, abdominal pain) had a lower ES of 0.47. Symptoms of early satiety, nausea, postprandial fullness, and bloating were responsive to treatment for gastroparesis. A composite of these symptoms also demonstrates validity and responsiveness to treatment for gastroparesis, and may represent an acceptable endpoint for evaluating the effectiveness of medical treatments in clinical trials for gastroparesis. © 2012 Blackwell Publishing Ltd.

  16. Validation of a combined health literacy and numeracy instrument for patients with type 2 diabetes.

    PubMed

    Luo, Huabin; Patil, Shivajirao P; Wu, Qiang; Bell, Ronny A; Cummings, Doyle M; Adams, Alyssa D; Hambidge, Bertha; Craven, Kay; Gao, Fei

    2018-05-20

    This study aimed to validate a new consolidated measure of health literacy and numeracy (health literacy scale [HLS] plus the subjective numeracy scale [SNS]) in patients with type 2 diabetes (T2DM). A convenience sample (N = 102) of patients with T2DM was recruited from an academic family medicine center in the southeastern US between September-December 2017. Participants completed a questionnaire that included the composite HLS/SNS (22 questions) and a commonly used objective measure of health literacy-S-TOFHLA (40 questions). Internal reliability of the HLS/SNS was assessed using Cronbach's alpha. Criterion and construct validity was assessed against the S-TOFHLA. The composite HLS/SNS had good internal reliability (Cronbach's alpha = 0.83). A confirmatory factor analysis revealed there were four factors in the new instrument. Model fit indices showed good model-data fit (RMSEA = 0.08). The Spearman's rank order correlation coefficient between the HLS/SNS and the S-TOFHLA was 0.45 (p < 0.01). Our study suggests that the composite HLS/SNS is a reliable, valid instrument. Published by Elsevier B.V.

  17. Evaluation of a Propolis Water Extract Using a Reliable RP-HPLC Methodology and In Vitro and In Vivo Efficacy and Safety Characterisation

    PubMed Central

    Rocha, Bruno Alves; Bueno, Paula Carolina Pires; Vaz, Mirela Mara de Oliveira Lima Leite; Nascimento, Andresa Piacezzi; Ferreira, Nathália Ursoli; Moreno, Gabriela de Padua; Rodrigues, Marina Rezende; Costa-Machado, Ana Rita de Mello; Barizon, Edna Aparecida; Campos, Jacqueline Costa Lima; de Oliveira, Pollyanna Francielli; Acésio, Nathália de Oliveira; Martins, Sabrina de Paula Lima; Tavares, Denise Crispim; Berretta, Andresa Aparecida

    2013-01-01

    Since the beginning of propolis research, several groups have studied its antibacterial, antifungal, and antiviral properties. However, most of these studies have only employed propolis ethanolic extract (PEE) leading to little knowledge about the biological activities of propolis water extract (PWE). Based on this, in a previous study, we demonstrated the anti-inflammatory and immunomodulatory activities of PWE. In order to better understand the equilibrium between effectiveness and toxicity, which is essential for a new medicine, the characteristics of PWE were analyzed. We developed and validated an RP-HPLC method to chemically characterize PWE and PEE and evaluated the in vitro antioxidant/antimicrobial activity for both extracts and the safety of PWE via determining genotoxic potential using in vitro and in vivo mammalian micronucleus assays. We have concluded that the proposed analytical methodology was reliable, and both extracts showed similar chemical composition. The extracts presented antioxidant and antimicrobial effects, while PWE demonstrated higher antioxidant activity and more efficacious for the most of the microorganisms tested than PEE. Finally, PWE was shown to be safe using micronucleus assays. PMID:23710228

  18. Reliability of concussion history in former professional football players.

    PubMed

    Kerr, Zachary Y; Marshall, Stephen W; Guskiewicz, Kevin M

    2012-03-01

    The reliability of athletes to recall and self-report a concussion history has never been quantified. This study examined the reliability of the self-report concussion history measure and explored determinants of recall in the number of self-reported concussions in a group of retired professional football players. In 2001, a short questionnaire was administered to a cohort of former professional football players to ascertain the number of self-reported concussions they sustained during their professional playing careers. In 2010, the same instrument was readministered to a subset (n = 899) of the original cohort to assess reliability. Overall reliability was moderate (weighted Cohen κ = 0.48). The majority (62.1%) reported the same number of concussions in both administrations (2001 and 2010); 31.4% reported more concussions in the second administration. Compared with the "same number reported" group, the "greater number reported" group had more deficits in the second administration in their Short Form 36 physical health (composite score combining physical functioning, role physical, bodily pain, general health) and mental health (e.g., composite score combining vitality, social functioning, role emotional) scales. The self-reported concussion history had moderate reliability in former professional football players, on the basis of two administrations of the same instrument, 9 yr apart. However, changes in health status may be differentially associated with recall of concussions.

  19. Study on evaluation of construction reliability for engineering project based on fuzzy language operator

    NASA Astrophysics Data System (ADS)

    Shi, Yu-Fang; Ma, Yi-Yi; Song, Ping-Ping

    2018-03-01

    System Reliability Theory is a research hotspot of management science and system engineering in recent years, and construction reliability is useful for quantitative evaluation of project management level. According to reliability theory and target system of engineering project management, the defination of construction reliability appears. Based on fuzzy mathematics theory and language operator, value space of construction reliability is divided into seven fuzzy subsets and correspondingly, seven membership function and fuzzy evaluation intervals are got with the operation of language operator, which provides the basis of corresponding method and parameter for the evaluation of construction reliability. This method is proved to be scientific and reasonable for construction condition and an useful attempt for theory and method research of engineering project system reliability.

  20. Integral nuclear data validation using experimental spent nuclear fuel compositions

    DOE PAGES

    Gauld, Ian C.; Williams, Mark L.; Michel-Sendis, Franco; ...

    2017-07-19

    Measurements of the isotopic contents of spent nuclear fuel provide experimental data that are a prerequisite for validating computer codes and nuclear data for many spent fuel applications. Under the auspices of the Organisation for Economic Co-operation and Development (OECD) Nuclear Energy Agency (NEA) and guidance of the Expert Group on Assay Data of Spent Nuclear Fuel of the NEA Working Party on Nuclear Criticality Safety, a new database of expanded spent fuel isotopic compositions has been compiled. The database, Spent Fuel Compositions (SFCOMPO) 2.0, includes measured data for more than 750 fuel samples acquired from 44 different reactors andmore » representing eight different reactor technologies. Measurements for more than 90 isotopes are included. This new database provides data essential for establishing the reliability of code systems for inventory predictions, but it also has broader potential application to nuclear data evaluation. Furthermore, the database, together with adjoint based sensitivity and uncertainty tools for transmutation systems developed to quantify the importance of nuclear data on nuclide concentrations, are described.« less

  1. Towards a Probabilistic Preliminary Design Criterion for Buckling Critical Composite Shells

    NASA Technical Reports Server (NTRS)

    Arbocz, Johann; Hilburger, Mark W.

    2003-01-01

    A probability-based analysis method for predicting buckling loads of compression-loaded laminated-composite shells is presented, and its potential as a basis for a new shell-stability design criterion is demonstrated and discussed. In particular, a database containing information about specimen geometry, material properties, and measured initial geometric imperfections for a selected group of laminated-composite cylindrical shells is used to calculate new buckling-load "knockdown factors". These knockdown factors are shown to be substantially improved, and hence much less conservative than the corresponding deterministic knockdown factors that are presently used by industry. The probability integral associated with the analysis is evaluated by using two methods; that is, by using the exact Monte Carlo method and by using an approximate First-Order Second- Moment method. A comparison of the results from these two methods indicates that the First-Order Second-Moment method yields results that are conservative for the shells considered. Furthermore, the results show that the improved, reliability-based knockdown factor presented always yields a safe estimate of the buckling load for the shells examined.

  2. Integral nuclear data validation using experimental spent nuclear fuel compositions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gauld, Ian C.; Williams, Mark L.; Michel-Sendis, Franco

    Measurements of the isotopic contents of spent nuclear fuel provide experimental data that are a prerequisite for validating computer codes and nuclear data for many spent fuel applications. Under the auspices of the Organisation for Economic Co-operation and Development (OECD) Nuclear Energy Agency (NEA) and guidance of the Expert Group on Assay Data of Spent Nuclear Fuel of the NEA Working Party on Nuclear Criticality Safety, a new database of expanded spent fuel isotopic compositions has been compiled. The database, Spent Fuel Compositions (SFCOMPO) 2.0, includes measured data for more than 750 fuel samples acquired from 44 different reactors andmore » representing eight different reactor technologies. Measurements for more than 90 isotopes are included. This new database provides data essential for establishing the reliability of code systems for inventory predictions, but it also has broader potential application to nuclear data evaluation. Furthermore, the database, together with adjoint based sensitivity and uncertainty tools for transmutation systems developed to quantify the importance of nuclear data on nuclide concentrations, are described.« less

  3. Delamination Modeling of Composites for Improved Crash Analysis

    NASA Technical Reports Server (NTRS)

    Fleming, David C.

    1999-01-01

    Finite element crash modeling of composite structures is limited by the inability of current commercial crash codes to accurately model delamination growth. Efforts are made to implement and assess delamination modeling techniques using a current finite element crash code, MSC/DYTRAN. Three methods are evaluated, including a straightforward method based on monitoring forces in elements or constraints representing an interface; a cohesive fracture model proposed in the literature; and the virtual crack closure technique commonly used in fracture mechanics. Results are compared with dynamic double cantilever beam test data from the literature. Examples show that it is possible to accurately model delamination propagation in this case. However, the computational demands required for accurate solution are great and reliable property data may not be available to support general crash modeling efforts. Additional examples are modeled including an impact-loaded beam, damage initiation in laminated crushing specimens, and a scaled aircraft subfloor structures in which composite sandwich structures are used as energy-absorbing elements. These examples illustrate some of the difficulties in modeling delamination as part of a finite element crash analysis.

  4. Construction of an efficient evaluative instrument for myasthenia gravis: the MG composite.

    PubMed

    Burns, Ted M; Conaway, Mark R; Cutter, Gary R; Sanders, Donald B

    2008-12-01

    We assessed the performance of items from the Quantitative Myasthenia Gravis (QMG), MMT (Manual Muscle Test), and MG-ADL (Myasthenia Gravis - Activities of Daily Living) scales, using data from two recently completed treatment trials of generalized MG. Items were selected that were relevant to manifestations of MG, meaningful to both the physician and the patient, and responsive to clinical change. After the 10 items were chosen, they were weighted based on input from MG experts from around the world, considering factors such as quality of life, disease severity, risk, prognosis, validity, and reliability. The MG Composite is easy to administer, takes less than 5 minutes to complete, and requires no equipment. Weighting of the response options of the 10 items should result in ordinal scores that better represent MG status and are more responsive to meaningful clinical change. To better determine its suitability for clinical use and for treatment trials, the MG Composite will be tested prospectively at several academic medical centers and will be used as a secondary measure of efficacy in pending clinical trials of MG.

  5. Social Skills Questionnaire for Argentinean College Students (SSQ-U) Development and Validation.

    PubMed

    Morán, Valeria E; Olaz, Fabián O; Del Prette, Zilda A P

    2015-11-27

    In this paper we present a new instrument called Social Skills Questionnaire for Argentinean College Students (SSQ-U). Based on the adapted version of the Social Skills Inventory - Del Prette (SSI-Del Prette) (Olaz, Medrano, Greco, & Del Prette, 2009), we wrote new items for the scale, and carried out psychometric analysis to assess the validity and reliability of the instrument. In the first study, we collected evidence based on test content through expert judges who evaluated the quality and the relevance of the items. In the second and third studies, we provided validity evidence based on the internal structure of the instrument using exploratory (n = 1067) and confirmatory (n = 661) factor analysis. Results suggested a five-factor structure consistent with the dimensions of social skills, as proposed by Kelly (2002). The fit indexes corresponding to the obtained model were adequate, and composite reliability coefficients of each factor were excellent (above .75). Finally, in the fourth study, we provided evidence of convergent and discriminant validity. The obtained results allow us to conclude that the SSQ-U is the first valid and reliable instrument for measuring social skills in Argentinean college students.

  6. Reliability of the hospital nutrition environment scan for cafeterias, vending machines, and gift shops.

    PubMed

    Winston, Courtney P; Sallis, James F; Swartz, Michael D; Hoelscher, Deanna M; Peskin, Melissa F

    2013-08-01

    According to ecological models, the physical environment plays a major role in determining individual health behaviors. As such, researchers have started targeting the consumer nutrition environment of large-scale foodservice operations when implementing obesity-prevention programs. In 2010, the American Hospital Association released a call-to-action encouraging health care facilities to join in this movement and improve their facilities' consumer nutrition environments. The Hospital Nutrition Environment Scan (HNES) for Cafeterias, Vending Machines, and Gift Shops was developed in 2011, and the present study evaluated the inter-rater reliability of this instrument. Two trained raters visited 39 hospitals in southern California and completed the HNES. Percent agreement, kappa statistics, and intraclass correlation coefficients were calculated. Percent agreement between raters ranged from 74.4% to 100% and kappa statistics ranged from 0.458 to 1.0. The intraclass correlation coefficient for the overall nutrition composite scores was 0.961. Given these results, the HNES demonstrated acceptable reliability metrics and can now be disseminated to assess the current state of hospital consumer nutrition environments. Copyright © 2013 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  7. Validation of the Resilience Scale for Adolescents in Norwegian adolescents 13-18 years.

    PubMed

    Moksnes, Unni K; Haugan, Gørill

    2018-03-01

    Resilience is seen as a vital resource for coping and mental health in adolescents. However, there is no universally accepted theory or definition of resilience, leading to considerable challenges regarding how to operationalise and measure this construct. The study aimed at providing further knowledge of the psychometric properties (dimensionality, construct validity and internal consistency) of the 28-item version of the Resilience Scale for Adolescents (READ) in N = 1183 Norwegian adolescents, 13-18 years old. Dimensionality of READ was tested using confirmatory factor analysis (CFA). Convergent validity and reliability were tested using Pearson's correlation analysis, Cronbach's alpha and composite reliability. The CFA supported a modified, 20-item, five-factor structure with high reliability, supporting the dimensionality and internal consistency of the instrument. Convergent validity was confirmed where all factors correlated in expected directions with measures of sense of coherence, self-esteem, stress and depression. The psychometric properties of the READ need to be further evaluated in adolescents; however, the results indicate that a modified 20-item version of READ is adequate for assessing resilience in the present sample of Norwegian adolescents. © 2017 Nordic College of Caring Science.

  8. Auditory color constancy: calibration to reliable spectral properties across nonspeech context and targets.

    PubMed

    Stilp, Christian E; Alexander, Joshua M; Kiefte, Michael; Kluender, Keith R

    2010-02-01

    Brief experience with reliable spectral characteristics of a listening context can markedly alter perception of subsequent speech sounds, and parallels have been drawn between auditory compensation for listening context and visual color constancy. In order to better evaluate such an analogy, the generality of acoustic context effects for sounds with spectral-temporal compositions distinct from speech was investigated. Listeners identified nonspeech sounds-extensively edited samples produced by a French horn and a tenor saxophone-following either resynthesized speech or a short passage of music. Preceding contexts were "colored" by spectral envelope difference filters, which were created to emphasize differences between French horn and saxophone spectra. Listeners were more likely to report hearing a saxophone when the stimulus followed a context filtered to emphasize spectral characteristics of the French horn, and vice versa. Despite clear changes in apparent acoustic source, the auditory system calibrated to relatively predictable spectral characteristics of filtered context, differentially affecting perception of subsequent target nonspeech sounds. This calibration to listening context and relative indifference to acoustic sources operates much like visual color constancy, for which reliable properties of the spectrum of illumination are factored out of perception of color.

  9. The Consumer Assessment of Healthcare Providers and Systems (CAHPS) cultural competence (CC) item set.

    PubMed

    Weech-Maldonado, Robert; Carle, Adam; Weidmer, Beverly; Hurtado, Margarita; Ngo-Metzger, Quyen; Hays, Ron D

    2012-09-01

    There is a need for reliable and valid measures of cultural competence (CC) from the patient's perspective. This paper evaluates the reliability and validity of the Consumer Assessments of Healthcare Providers and Systems (CAHPS) CC item set. Using 2008 survey data, we assessed the internal consistency of the CAHPS CC scales using the Cronbach α's and examined the validity of the measures using exploratory and confirmatory factor analysis, multitrait scaling analysis, and regression analysis. A random stratified sample (based on race/ethnicity and language) of 991 enrollees, younger than 65 years, from 2 Medicaid managed care plans in California and New York. CAHPS CC item set after excluding screener items and ratings. Confirmatory factor analysis (Comparative Fit Index=0.98, Tucker Lewis Index=0.98, and Root Mean Square Error or Approximation=0.06) provided support for a 7-factor structure: Doctor Communication--Positive Behaviors, Doctor Communication--Negative Behaviors, Doctor Communication--Health Promotion, Doctor Communication--Alternative Medicine, Shared Decision-Making, Equitable Treatment, and Trust. Item-total correlations (corrected for item overlap) for the 7 scales exceeded 0.40. Exploratory factor analysis showed support for 1 additional factor: Access to Interpreter Services. Internal consistency reliability estimates ranged from 0.58 (Alternative Medicine) to 0.92 (Positive Behaviors) and was 0.70 or higher for 4 of the 8 composites. All composites were positively and significantly associated with the overall doctor rating. The CAHPS CC 26-item set demonstrates adequate measurement properties and can be used as a supplemental item set to the CAHPS Clinician and Group Surveys in assessing culturally competent care from the patient's perspective.

  10. Development and Validation of a Family Meeting Assessment Tool (FMAT).

    PubMed

    Hagiwara, Yuya; Healy, Jennifer; Lee, Shuko; Ross, Jeanette; Fischer, Dixie; Sanchez-Reilly, Sandra

    2018-01-01

    A cornerstone procedure in Palliative Medicine is to perform family meetings. Learning how to lead a family meeting is an important skill for physicians and others who care for patients with serious illnesses and their families. There is limited evidence on how to assess best practice behaviors during end-of-life family meetings. Our aim was to develop and validate an observational tool to assess trainees' ability to lead a simulated end-of-life family meeting. Building on evidence from published studies and accrediting agency guidelines, an expert panel at our institution developed the Family Meeting Assessment Tool. All fourth-year medical students (MS4) and eight geriatric and palliative medicine fellows (GPFs) were invited to participate in a Family Meeting Objective Structured Clinical Examination, where each trainee assumed the physician role leading a complex family meeting. Two evaluators observed and rated randomly chosen students' performances using the Family Meeting Assessment Tool during the examination. Inter-rater reliability was measured using percent agreement. Internal consistency was measured using Cronbach α. A total of 141 trainees (MS4 = 133 and GPF = 8) and 26 interdisciplinary evaluators participated in the study. Internal reliability (Cronbach α) of the tool was 0.85. Number of trainees rated by two evaluators was 210 (MS4 = 202 and GPF = 8). Rater agreement was 84%. Composite scores, on average, were significantly higher for fellows than for medical students (P < 0.001). Expert-based content, high inter-rater reliability, good internal consistency, and ability to predict educational level provided initial evidence for construct validity for this novel assessment tool. Copyright © 2017 American Academy of Hospice and Palliative Medicine. All rights reserved.

  11. Flywheel Rotor Safe-Life Technology

    NASA Technical Reports Server (NTRS)

    Ratner, J. K. H.; Chang, J. B.; Christopher, D. A.; McLallin, Kerry L. (Technical Monitor)

    2002-01-01

    Since the 1960s, research has been conducted into the use of flywheels as energy storage systems. The-proposed applications include energy storage for hybrid and electric automobiles, attitude control and energy storage for satellites, and uninterruptible power supplies for hospitals and computer centers. For many years, however, the use of flywheels for space applications was restricted by the total weight of a system employing a metal rotor. With recent technological advances in the manufacturing of composite materials, however, lightweight composite rotors have begun to be proposed for such applications. Flywheels with composite rotors provide much higher power and energy storage capabilities than conventional chemical batteries. However, the failure of a high speed flywheel rotor could be a catastrophic event. For this reason, flywheel rotors are classified by the NASA Fracture Control Requirements Standard as fracture critical parts. Currently, there is no industry standard to certify a composite rotor for safe and reliable operation forth( required lifetime of the flywheel. Technical problems hindering the development of this standard include composite manufacturing inconsistencies, insufficient nondestructive evaluation (NDE) techniques for detecting defects and/or impact damage, lack of standard material test methods for characterizing composite rotor design allowables, and no unified proof (over-spin) test for flight rotors. As part of a flywheel rotor safe-life certification pro-ram funded b the government, a review of the state of the art in composite rotors is in progress. The goal of the review is to provide a clear picture of composite flywheel rotor technologies. The literature review has concentrated on the following topics concerning composites and composite rotors: durability (fatigue) and damage tolerance (safe-life) analysis/test methods, in-service NDE and health monitoring techniques, spin test methods/ procedures, and containment options. This report presents the papers selected for their relevance to this topic and summarizes them.

  12. High Performance COPVs for In-Space Storage of High Pressure Cryogenic Fuels

    NASA Technical Reports Server (NTRS)

    Schneider, Judy; Dyess, Mark; Hastings, Chad; Wang, Jun

    2008-01-01

    Polymeric composite overwrapped pressure vessels (COPVs) provide an attractive material system to support developing commercial launch business and alternate fuel ventures. However to be able to design with these materials, the mechanical behavior of the materials must be understood with regards to processing, performance, damage tolerance, and environment. For the storage of cryogenic propellants, it is important to evaluate the materials performance and impact damage resistance at cryogenic temperatures in order to minimize weight and to ensure safety and reliability. As part of this study, material tests of candidate fiber and resin systems were used as the basis for the selection of the material combinations for evaluation in a COPV at cryogenic conditions. This comprehensive approach has also been expanded to address issues with impact damage tolerance and material degradation due to environmental factors. KEY WORDS: Cryogenic testing, evaluation and applications for pressure vessels, COPVs, tanks, or storage vessels.

  13. [Comparative studies on fissure sealing: composite versus Cermet cement].

    PubMed

    Hickel, R; Voss, A

    1989-06-01

    Fifty two molars sealed with either composite or Cermet cement were compared. The composite sealant was applied after enamel etching using a rubber dam. Before sealing with Cermet cement the enamel was only cleaned with pumice powder and sodium hypochlorie and the material was applied without enamel etching. After an average follow-up of 1.6 years composite sealants proved to be significantly more reliable. Cermet cement sealings showed defects more frequently.

  14. Analysis of whisker-toughened CMC structural components using an interactive reliability model

    NASA Technical Reports Server (NTRS)

    Duffy, Stephen F.; Palko, Joseph L.

    1992-01-01

    Realizing wider utilization of ceramic matrix composites (CMC) requires the development of advanced structural analysis technologies. This article focuses on the use of interactive reliability models to predict component probability of failure. The deterministic William-Warnke failure criterion serves as theoretical basis for the reliability model presented here. The model has been implemented into a test-bed software program. This computer program has been coupled to a general-purpose finite element program. A simple structural problem is presented to illustrate the reliability model and the computer algorithm.

  15. A phylogenetic comparison of urease-positive thermophilic Campylobacter (UPTC) and urease-negative (UN) C. lari.

    PubMed

    Hirayama, Junichi; Tazumi, Akihiro; Hayashi, Kyohei; Tasaki, Erina; Kuribayashi, Takashi; Moore, John E; Millar, Beverley C; Matsuda, Motoo

    2011-06-01

    In the present study, the reliability of full-length gene sequence information for several genes including 16S rRNA was examined, for the discrimination of the two representative Campylobacter lari taxa, namely urease-negative (UN) C. lari and urease-positive thermophilic Campylobacter (UPTC). As previously described, 16S rRNA gene sequence are not reliable for the molecular discrimination of UN C. lari from UPTC organisms employing both the unweighted pair group method using arithmetic means analysis (UPGMA) and neighbor joining (NJ) methods. In addition, three composite full-length gene sequences (ciaB, flaC and vacJ) out of seven gene loci examined were reliable for discrimination employing dendrograms constructed by the UPGMA method. In addition, all the dendrograms of the NJ phylogenetic trees constructed based on the nine gene information were not reliable for the discrimination. Three composite full-length gene sequences (ciaB, flaC and vacJ) were reliable for the molecular discrimination between UN C. lari and UPTC organisms employing the UPGMA method, as well as among four thermophilic Campylobacter species. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Scores Assigned by Inexpert EFL Raters to Different Quality EFL Compositions, and the Raters' Decision-Making Behaviors

    ERIC Educational Resources Information Center

    Han, Turgay

    2017-01-01

    The aim of this study is to examine the variability in and reliability of scores assigned to different quality EFL compositions by EFL instructors and their rating behaviors. Using a mixed research design, quantitative data were collected from EFL instructors' ratings of 30 compositions of three different qualities using a holistic scoring rubric.…

  17. Technology Base Enhancement Program. Metal Matrix Composites

    DTIC Science & Technology

    1993-08-30

    efficiency, improved structural reliability, and reduced maintenance when compared to carbon fiber reinforced composites . Aerospace engines (in particular...different materials. The composite consists of a metal matrix reinforced with particulates, flakes, whiskers,3 continuous fibers , filaments, wires, or...graphite and carbon to metals. They come in three general forms: particulates (or particles) with a length to diameter ratio of about 1; chopped fibers or

  18. Eighth DOD/NASA/FAA Conference on Fibrous Composites in Structural Design, Part 2

    NASA Technical Reports Server (NTRS)

    Starnes, James H., Jr. (Compiler); Bohon, Herman L. (Compiler); Garzon, Sherry B. (Compiler)

    1990-01-01

    Papers presented at the conference are compiled. The conference provided a forum for the scientific community to exchange composite structures design information and an opportunity to observe recent progress in composite structures design and technology. Part 2 contains papers related to the following subject areas: the application in design; methodology in design; and reliability in design.

  19. Ultrasonic nonlinear guided wave inspection of microscopic damage in a composite structure

    NASA Astrophysics Data System (ADS)

    Zhang, Li; Borigo, Cody; Owens, Steven; Lissenden, Clifford; Rose, Joseph; Hakoda, Chris

    2017-02-01

    Sudden structural failure is a severe safety threat to many types of military and industrial composite structures. Because sudden structural failure may occur in a composite structure shortly after macroscale damage initiates, reliable early diagnosis of microdamage formation in the composite structure is critical to ensure safe operation and to reduce maintenance costs. Ultrasonic guided waves have been widely used for long-range defect detection in various structures. When guided waves are generated under certain excitation conditions, in addition to the traditional linear wave mode (known as the fundamental harmonic wave mode), a number of nonlinear higher-order harmonic wave modes are also be generated. Research shows that the nonlinear parameters of a higher-order harmonic wave mode could have excellent sensitivity to microstructural changes in a material. In this work, we successfully employed a nonlinear guided wave structural health monitoring (SHM) method to detect microscopic impact damage in a 32-layer carbon/epoxy fiber-reinforced composite plate. Our effort has demonstrated that, utilizing appropriate transducer design, equipment, excitation signals, and signal processing techniques, nonlinear guided wave parameter measurements can be reliably used to monitor microdamage initiation and growth in composite structures.

  20. Cross-Cultural Translation, Adaptation and Reliability of the Danish M. D. Andeson Dysphagia Inventory (MDADI) in Patients with Head and Neck Cancer.

    PubMed

    Hajdú, Sara Fredslund; Plaschke, Christina Caroline; Johansen, Christoffer; Dalton, Susanne Oksbjerg; Wessel, Irene

    2017-08-01

    The objectives were to translate and culturally adapt the M.D. Anderson Dysphagia Inventory (MDADI) into Danish and subsequently test the reliability of the Danish version. The MDADI was translated into Danish and cross culturally adapted through cognitive interviews. The final version was test-retest evaluated in a group of head and neck cancer (HNC) patients who responded to the questionnaire twice with a mean of eight days apart. Interclass correlation coefficient, Cronbach's alpha, floor and ceiling effects, standard error of measurement and minimal detectable change were investigated. Fourteen patients were interviewed on the comprehensibility of the Danish MDADI, and all found the questionnaire meaningful, easy to understand, non-offensive and to include relevant aspects of dysphagia related to HNC. Sixty-four patients were included in the test-retest study. Especially, one item in the emotional scale (E7) appeared to be often misinterpreted, and ceiling effects were found in all four subdomains (global, emotional, functional and physical). The four subdomains and the composite score showed acceptable test-retest reliability and internal consistency in a Danish population of HNC patients. The Danish MDADI is reliable in terms of internal consistency and test-retest reproducibility and can be used in assessing the health-related quality of life in head and neck cancer patients with dysphagia.

  1. The Relation between Polyphenols and Body Composition in US Hispanics/Latinos: Results from the Hispanic Community Health Study/Study of Latinos (HCHS/SOL) Study of Latinos Nutrition and Physical Activity Assessment Study (SOLNAS)

    PubMed Central

    Makarem, Nour; Mossavar-Rahmani, Yasmin; Hua, Simin; Wong, William W; Van Horn, Linda; Daviglus, Martha L; Franke, Adrian A; Gellman, Marc D; Kaplan, Robert C; Beasley, Jeannette M

    2017-01-01

    Abstract Background: Polyphenols offer high antioxidant potential that may protect against chronic diseases. Epidemiologic evidence documenting their influence on body composition and obesity risk is limited, particularly among Hispanics/Latinos who are disproportionately prone to obesity. Objectives: The aims of this study were to evaluate cross-sectional associations of urinary polyphenols with body mass index (BMI) and body fat percentage (%BF) in a diverse Hispanic/Latino population and to assess the reliability of polyphenol measurements. Methods: Participants were 442 adults from the Study of Latinos/Nutrition and Physical Activity Assessment Study (SOLNAS) aged 18–74 y. Doubly labeled water was used as an objective recovery biomarker of energy. Polyphenol excretion from 24-h urine samples was assessed. Measures were repeated in a subsample (n = 90) to provide a reliability measure. Anthropometric measures were obtained by trained personnel, and %BF was measured by 18O dilution. Linear regression models were used to evaluate multivariable associations between body composition and polyphenols. Spearman correlation coefficients between BMI and %BF with polyphenols and intraclass correlation coefficients (ICCs) between polyphenol measures were computed. Results: A weak correlation was observed for resveratrol and %BF (r = −0.11, P = 0.02). In multivariable-adjusted regression models, weak inverse associations were observed for resveratrol and urolithin A with %BF [β ± SE: −0.010 ± 0.004 (P = 0.007) and −0.004 ± 0.002 (P = 0.03), respectively]. For every 50% increase in these urinary polyphenols, there was a 1% and 0.4% decrease in %BF. Urolithin A was inversely associated with BMI (β ± SE: −0.004 ± 0.002; P = 0.02) and with 5% lower odds of obesity in models not adjusted for total energy expenditure (TEE; OR: 0.95; 95% CI: 0.91, 0.99; P = 0.02). For every 50% increase in urolithin A, there was a 0.4-unit decrease in BMI. Associations were attenuated after adjustment for TEE. Reliability study findings were indicative of weak to moderate correlations (ICCs: 0.11–0.65), representing a degree of within-person variation in polyphenol biomarkers. Conclusions: Although associations were weak, resveratrol and urolithin A were inversely associated with obesity. Repeated polyphenol urine measures could clarify their long-term impact on body adiposity.

  2. Development of a Standard Set of Software Indicators for Aeronautical Systems Center.

    DTIC Science & Technology

    1992-09-01

    29:12). The composite models listed include COCOMO and the Software Productivity, Quality, and Reliability Model ( SPQR ) (29:12). The SPQR model was...determine the values of the 68 input parameters. Source provides no specifics. Indicator Name SPQR (SW Productivity, Qual, Reliability) Indicator Class

  3. 32 CFR 32.53 - Retention and access requirements for records.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., reliability, and security of the original computer data. Recipients shall also maintain an audit trail... group of costs is chargeable (such as computer usage chargeback rates or composite fringe benefit rates... maintained on a computer, recipients shall retain the computer data on a reliable medium for the time periods...

  4. 32 CFR 32.53 - Retention and access requirements for records.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., reliability, and security of the original computer data. Recipients shall also maintain an audit trail... group of costs is chargeable (such as computer usage chargeback rates or composite fringe benefit rates... maintained on a computer, recipients shall retain the computer data on a reliable medium for the time periods...

  5. 32 CFR 32.53 - Retention and access requirements for records.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., reliability, and security of the original computer data. Recipients shall also maintain an audit trail... group of costs is chargeable (such as computer usage chargeback rates or composite fringe benefit rates... maintained on a computer, recipients shall retain the computer data on a reliable medium for the time periods...

  6. DOE research and development report. Progress report, October 1980-September 1981

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bingham, Carleton D.

    The DOE New Brunswick Laboratory (NBL) is the US Government's Nuclear Materials Standards and Measurement Laboratory. NBL is assigned the mission to provide and maintain, as an essential part of federal statutory responsibilities related to national and international safeguards of nuclear materials for USA defense and energy programs, an ongoing capability for: the development, preparation, certification, and distribution of reference materials for the calibration and standardization of nuclear materials measurements; the development, improvement, and evaluation of nuclear materials measurement technology; the assessment and evaluation of the practice and application of nuclear materials measurement technology; expert and reliable specialized nuclear materialsmore » measurement services for the government; and technology exchange and training in nuclear materials measurement and standards. Progress reports for this fiscal year are presented under the following sections: (1) development or evaluation of measurement technology (elemental assay of uranium plutonium; isotope composition); (2) standards and reference materials (NBL standards and reference materials; NBS reference materials); and (3) evaluation programs (safeguards analytical laboratory evaluation; general analytical evaluation program; other evaluation programs).« less

  7. Validity and reliability of bioelectrical impedance analysis and skinfold thickness in predicting body fat in military personnel.

    PubMed

    Aandstad, Anders; Holtberget, Kristian; Hageberg, Rune; Holme, Ingar; Anderssen, Sigmund A

    2014-02-01

    Previous studies show that body composition is related to injury risk and physical performance in soldiers. Thus, valid methods for measuring body composition in military personnel are needed. The frequently used body mass index method is not a valid measure of body composition in soldiers, but reliability and validity of alternative field methods are less investigated in military personnel. Thus, we carried out test and retest of skinfold (SKF), single frequency bioelectrical impedance analysis (SF-BIA), and multifrequency bioelectrical impedance analysis measurements in 65 male and female soldiers. Several validated equations were used to predict percent body fat from these methods. Dual-energy X-ray absorptiometry was also measured, and acted as the criterion method. Results showed that SF-BIA was the most reliable method in both genders. In women, SF-BIA was also the most valid method, whereas SKF or a combination of SKF and SF-BIA produced the highest validity in men. Reliability and validity varied substantially among the equations examined. The best methods and equations produced test-retest 95% limits of agreement below ±1% points, whereas the corresponding validity figures were ±3.5% points. Each investigator and practitioner must consider whether such measurement errors are acceptable for its specific use. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.

  8. Cross-cultural adaptation, content validation, and reliability of the Nigerian Composite Lifestyle CVD Risk Factors Questionnaire for adolescents among Yoruba rural adolescents in Nigeria.

    PubMed

    Odunaiya, Nse A; Louw, Quinette A; Grimmer, Karen

    2017-06-01

    Assessment of lifestyle risk factors must be culturally- and contextually relevant and available in local languages. This paper reports on a study which aimed to cross culturally adapt a composite lifestyle cardiovascular disease (CVD) risk factors questionnaire into an African language (Yoruba) and testing some of its psychometric properties such as content validity and test retest reliability in comparison to the original English version. This study utilized a cross sectional design. Translation of the English version of the questionnaire into Yoruba was undertaken using the guideline by Beaton et al. The translated instrument was presented to 21 rural adolescents to assess comprehensibility and clarity using a sample of convenience. A test retest reliability was conducted among 150 rural adolescents using a purposive sampling. Data was analyzed using intraclass correlation (ICC ) model 3, Cohen kappa statistics and prevalence rates. ICC ranged between 0.4-0.8. The Yoruba version was completed 15-20 minutes and was reported to be culturally appropriate and acceptable for rural Nigerian adolescents. The Yoruba translation of the Nigerian composite lifestyle risk factors questionnaire performs at least as well as the original English version in terms of content validity and reliability. It took a shorter time to complete therefore may be more relevant to rural adolescents.

  9. Development and Psychometric Evaluation of a Health-Related Quality of Life Instrument for Individuals with Adult-Onset Hearing Loss

    PubMed Central

    Stika, Carren J.; Hays, Ron D.

    2016-01-01

    Objective Self-reports of “hearing handicap” are available, but a comprehensive measure of health-related quality of life (HRQOL) for individuals with adult-onset hearing loss (AOHL) does not exist. Our objective was to develop and evaluate a multidimensional HRQOL instrument for individuals with AOHL. Design The Impact of Hearing Loss Inventory Tool (IHEAR-IT) was developed using results of focus groups, a literature review, Advisory Expert Panel input, and cognitive interviews. Study Sample The 73-item field-test instrument was completed by 409 adults (22-91 years old) with varying degrees of AOHL and from different areas of the US. Results Multitrait scaling analysis supported four multi-item scales and five individual items. Internal consistency reliabilities ranged from 0.93 to 0.96 for the scales. Construct validity was supported by correlations between the IHEAR-IT scales and scores on the 36-Item Short Form Health Survey, Version 2.0 (SF-36v2) Mental Composite Summary (r’s = 0.32 – 0.64) and the Hearing Handicap Inventory for the Elderly/Adults (HHIE/HHIA) (r’s > −0.70). Conclusions The field test provide initial support for the reliability and construct validity of the IHEAR-IT for evaluating HRQOL of individuals with AOHL. Further research is needed to evaluate the responsiveness to change of the IHEAR-IT scales and identify items for a short-form. PMID:27104754

  10. Preliminary appraisal of the reliability and validity of the Colorado State University Feline Acute Pain Scale.

    PubMed

    Shipley, Hilary; Guedes, Alonso; Graham, Lynelle; Goudie-DeAngelis, Elizabeth; Wendt-Hornickle, Erin

    2018-05-01

    Objectives The objective of this study was to determine the inter-rater reliability and convergent validity of the Colorado State University Feline Acute Pain Scale (CSU-FAPS) in a preliminary appraisal of its performance in a clinical teaching setting. Methods Sixty-eight female cats were assessed for pain after ovariohysterectomy. A cohort of 21 cats was examined independently by four raters (two board-certified anesthesiologists and two anesthesia residents) with the CSU-FAPS, and intra-class correlation coefficient (ICC) was used to determine inter-rater reliability. Weighted Cohen's kappa was used to determine inter-rater reliability centered on the 'need to reassess analgesic plan' (dichotomous scale). A separate cohort of 47 cats was evaluated independently by two raters (one board-certified anesthesiologist and one veterinary small animal rotating intern) using the CSU-FAPS and the Glasgow Composite Measure Pain Scale (CMPS-Feline), and Spearman rank-order correlation was determined to assess convergent validity. Reliability was interpreted using Altman's classification as very good, good, moderate, fair and poor. Validity was considered adequate if correlation coefficients were between 0.4 and 0.8. Results The ICC was 0.61 for anesthesiologists and 0.67 for residents, indicating good reliability. Weighted Cohen's kappa was 0.79 for anesthesiologists and 0.44 for residents, indicating moderate to good reliability. The Spearman rank correlation indicated a statistically significant ( P = 0.0003) positive correlation (0.31; 95% confidence interval 0.14-0.46) between the CSU-FAPS and the CMPS-Feline. Conclusions and relevance The CSU-FAPS showed moderate-to-good inter-rater reliability when used by veterinarians to assess pain level or need to reassess analgesic plan after ovariohysterectomy in cats. The validity fell short of current guidelines for correlation coefficients and further refinement and testing are warranted to improve its performance.

  11. Validation of the English version of the UNESP-Botucatu multidimensional composite pain scale for assessing postoperative pain in cats

    PubMed Central

    2013-01-01

    Background A scale validated in one language is not automatically valid in another language or culture. The purpose of this study was to validate the English version of the UNESP-Botucatu multidimensional composite pain scale (MCPS) to assess postoperative pain in cats. The English version was developed using translation, back-translation, and review by individuals with expertise in feline pain management. In sequence, validity and reliability tests were performed. Results Of the three domains identified by factor analysis, the internal consistency was excellent for ‘pain expression’ and ‘psychomotor change’ (0.86 and 0.87) but not for ‘physiological variables’ (0.28). Relevant changes in pain scores at clinically distinct time points (e.g., post-surgery, post-analgesic therapy), confirmed the construct validity and responsiveness (Wilcoxon test, p < 0.001). Favorable correlation with the IVAS scores (p < 0.001) and moderate to very good agreement between blinded observers and ‘gold standard’ evaluations, supported criterion validity. The cut-off point for rescue analgesia was > 7 (range 0–30 points) with 96.5% sensitivity and 99.5% specificity. Conclusions The English version of the UNESP-Botucatu-MCPS is a valid, reliable and responsive instrument for assessing acute pain in cats undergoing ovariohysterectomy, when used by anesthesiologists or anesthesia technicians. The cut-off point for rescue analgesia provides an additional tool for guiding analgesic therapy. PMID:23867090

  12. Validation of the English version of the UNESP-Botucatu multidimensional composite pain scale for assessing postoperative pain in cats.

    PubMed

    Brondani, Juliana T; Mama, Khursheed R; Luna, Stelio P L; Wright, Bonnie D; Niyom, Sirirat; Ambrosio, Jennifer; Vogel, Pamela R; Padovani, Carlos R

    2013-07-17

    A scale validated in one language is not automatically valid in another language or culture. The purpose of this study was to validate the English version of the UNESP-Botucatu multidimensional composite pain scale (MCPS) to assess postoperative pain in cats. The English version was developed using translation, back-translation, and review by individuals with expertise in feline pain management. In sequence, validity and reliability tests were performed. Of the three domains identified by factor analysis, the internal consistency was excellent for 'pain expression' and 'psychomotor change' (0.86 and 0.87) but not for 'physiological variables' (0.28). Relevant changes in pain scores at clinically distinct time points (e.g., post-surgery, post-analgesic therapy), confirmed the construct validity and responsiveness (Wilcoxon test, p < 0.001). Favorable correlation with the IVAS scores (p < 0.001) and moderate to very good agreement between blinded observers and 'gold standard' evaluations, supported criterion validity. The cut-off point for rescue analgesia was > 7 (range 0-30 points) with 96.5% sensitivity and 99.5% specificity. The English version of the UNESP-Botucatu-MCPS is a valid, reliable and responsive instrument for assessing acute pain in cats undergoing ovariohysterectomy, when used by anesthesiologists or anesthesia technicians. The cut-off point for rescue analgesia provides an additional tool for guiding analgesic therapy.

  13. Psychometric evaluation of dietary self-efficacy and outcome expectation scales in female college freshmen.

    PubMed

    Kedem, Leia E; Evans, Ellen M; Chapman-Novakofski, Karen

    2014-11-01

    Lifestyle interventions commonly measure psychosocial beliefs as precursors to positive behavior change, but often overlook questionnaire validation. This can affect measurement accuracy if the survey has been developed for a different population, as differing behavioral influences may affect instrument validity. The present study aimed to explore psychometric properties of self-efficacy and outcome expectation scales-originally developed for younger children-in a population of female college freshmen (N = 268). Exploratory principal component analysis was used to investigate underlying data patterns and assess validity of previously published subscales. Composite scores for reliable subscales (Cronbach's α ≥ .70) were calculated to help characterize self-efficacy and outcome expectation beliefs in this population. The outcome expectation factor structure clearly comprised of positive (α = .81-.90) and negative outcomes (α = .63-.67). The self-efficacy factor structure included themes of motivation and effort (α = .75-.94), but items pertaining to hunger and availability cross-loaded often. Based on cross-loading patterns and low Cronbach's alpha values, respectively, self-efficacy items regarding barriers to healthy eating and negative outcome expectation items should be refined to improve reliability. Composite scores suggested that eating healthfully was associated with positive outcomes, but self-efficacy to do so was lower. Thus, dietary interventions for college students may be more successful by including skill-building activities to enhance self-efficacy and increase the likelihood of behavior change. © The Author(s) 2014.

  14. Are body size and volatile blends honest signals in orchid bees?

    PubMed

    Arriaga-Osnaya, Brenda Jessica; Contreras-Garduño, Jorge; Espinosa-García, Francisco Javier; García-Rodríguez, Yolanda Magdalena; Moreno-García, Miguel; Lanz-Mendoza, Humberto; Godínez-Álvarez, Héctor; Cueva Del Castillo, Raúl

    2017-05-01

    Secondary sexual traits may convey reliable information about males' ability to resist pathogens and that females may prefer those traits because their genes for resistance would be passed on to their offspring. In many insect species, large males have high mating success and can canalize more resources to the immune function than smaller males. In other species, males use pheromones to identify and attract conspecific mates, and thus, they might function as an honest indicator of a male's condition. The males of orchid bees do not produce pheromones. They collect and store flower volatiles, which are mixed with the volatile blends from other sources, like fungi, sap and resins. These blends are displayed as perfumes during the courtship. In this study, we explored the relationship between inter-individual variation in body size and blend composition with the males' phenoloxidase (PO) content in Euglossa imperialis . PO content is a common measure of insect immune response because melanine, its derived molecule, encapsulates parasites and pathogens. Body size and blend composition were related to bees' phenolic PO content. The inter-individual variation in body size and tibial contents could indicate differences among males in their skills to gain access to some compounds. The females may evaluate their potential mates through these compounds because some of them are reliable indicators of the males' capacity to resist infections and parasites.

  15. Body composition prediction equations based on deuterium oxide dilution method in Mexican children: a national study.

    PubMed

    Ramírez, E; Valencia, M E; Bourges, H; Espinosa, T; Moya-Camarena, S Y; Salazar, G; Alemán-Mateo, H

    2012-10-01

    Obesity and undernutrition co-exist in many regions of Mexico. However, accurate assessments are difficult because epidemiological data on body composition are not available. The aim of this study was to facilitate assessments of body composition in Mexican school children of different geographical regions and ethnicity by developing equations for bioelectrical impedance and anthropometry based on deuterium oxide dilution. We evaluated 336 subjects (143 belonged to six major indigenous groups) from Northern, Central and Southern Mexico. We measured height (Ht), weight (Wt), tricipital skinfold (Tricp-SKF) and resistance (R) based on a bioimpedance analysis (BIA). Fat-free mass (FFM) and fat mass (FM) were estimated from measurements of total body water with the deuterium dilution technique. The final BIA equation was FFM (kg)=0.661 × Ht²/R+0.200 × Wt-0.320. The R² was 0.96; the square root of the mean square error (SRMSE) was 1.39 kg. The final anthropometric equation was FM (kg)=-1.067 × sex+0.458 × Tricp-SKF+0.263 × Wt-5.407. The R² was 0.91; SRMSE was 1.60 kg. The BIA equation had a bias of 0.095 kg and precision of 1.43 kg. The anthropometric equation had a bias of 0.047 kg and precision of 1.58 kg. We validated two equations for evaluating body composition in Mexican indigenous and non-indigenous children and youth from three main regions of the country. These equations provided reliable estimates and will promote a better understanding of both obesity and undernutrition.

  16. Improving reliability of a residency interview process.

    PubMed

    Peeters, Michael J; Serres, Michelle L; Gundrum, Todd E

    2013-10-14

    To improve the reliability and discrimination of a pharmacy resident interview evaluation form, and thereby improve the reliability of the interview process. In phase 1 of the study, authors used a Many-Facet Rasch Measurement model to optimize an existing evaluation form for reliability and discrimination. In phase 2, interviewer pairs used the modified evaluation form within 4 separate interview stations. In phase 3, 8 interviewers individually-evaluated each candidate in one-on-one interviews. In phase 1, the evaluation form had a reliability of 0.98 with person separation of 6.56; reproducibly, the form separated applicants into 6 distinct groups. Using that form in phase 2 and 3, our largest variation source was candidates, while content specificity was the next largest variation source. The phase 2 g-coefficient was 0.787, while confirmatory phase 3 was 0.922. Process reliability improved with more stations despite fewer interviewers per station-impact of content specificity was greatly reduced with more interview stations. A more reliable, discriminating evaluation form was developed to evaluate candidates during resident interviews, and a process was designed that reduced the impact from content specificity.

  17. Claims about the Reliability of Student Evaluations of Instruction: The Ecological Fallacy Rides Again

    ERIC Educational Resources Information Center

    Morley, Donald D.

    2012-01-01

    The vast majority of the research on student evaluation of instruction has assessed the reliability of groups of courses and yielded either a single reliability coefficient for the entire group, or grouped reliability coefficients for each student evaluation of teaching (SET) item. This manuscript argues that these practices constitute a form of…

  18. Prediction of Process-Induced Distortions in L-Shaped Composite Profiles Using Path-Dependent Constitutive Law

    NASA Astrophysics Data System (ADS)

    Ding, Anxin; Li, Shuxin; Wang, Jihui; Ni, Aiqing; Sun, Liangliang; Chang, Lei

    2016-10-01

    In this paper, the corner spring-in angles of AS4/8552 L-shaped composite profiles with different thicknesses are predicted using path-dependent constitutive law with the consideration of material properties variation due to phase change during curing. The prediction accuracy mainly depends on the properties in the rubbery and glassy states obtained by homogenization method rather than experimental measurements. Both analytical and finite element (FE) homogenization methods are applied to predict the overall properties of AS4/8552 composite. The effect of fiber volume fraction on the properties is investigated for both rubbery and glassy states using both methods. And the predicted results are compared with experimental measurements for the glassy state. Good agreement is achieved between the predicted results and available experimental data, showing the reliability of the homogenization method. Furthermore, the corner spring-in angles of L-shaped composite profiles are measured experimentally and the reliability of path-dependent constitutive law is validated as well as the properties prediction by FE homogenization method.

  19. Versatile composite resins simplifying the practice of restorative dentistry.

    PubMed

    Margeas, Robert

    2014-01-01

    After decades of technical development and refinement, composite resins continue to simplify the practice of restorative dentistry, offering clinicians versatility, predictability, and enhanced physical properties. With a wide range of products available today, composite resins are a reliable, conservative, multi-functional restorative material option. As manufacturers strive to improve such properties as compression strength, flexural strength, elastic modulus, coefficient of thermal expansion, water sorption, and wear resistance, several classification systems of composite resins have been developed.

  20. Advanced composites characterization with x-ray technologies

    NASA Astrophysics Data System (ADS)

    Baaklini, George Y.

    1993-12-01

    Recognizing the critical need to advance new composites for the aeronautics and aerospace industries, we are focussing on advanced test methods that are vital to successful modeling and manufacturing of future generations of high temperature and durable composite materials. These newly developed composites are necessary to reduce propulsion cost and weight, to improve performance and reliability, and to address longer-term national strategic thrusts for sustaining global preeminence in high speed air transport and in high performance military aircraft.

  1. Assessing quality of life in patients with prostate cancer: a systematic and standardized comparison of available instruments.

    PubMed

    Schmidt, Stefanie; Garin, Olatz; Pardo, Yolanda; Valderas, José M; Alonso, Jordi; Rebollo, Pablo; Rajmil, Luis; Garcia-Forero, Carlos; Ferrer, Montse

    2014-10-01

    The objective was to obtain a standardized evaluation of available prostate cancer-specific quality of life instruments used in patients with early-stage disease. We carried out systematic literature reviews in the PubMed database to identify manuscripts which contained information regarding either the development process or metric properties of prostate cancer-specific quality of life instruments. Each instrument was evaluated by two experts, independently, using the Evaluating Measures of Patient-Reported Outcomes (EMPRO) tool. An overall and seven attribute-specific EMPRO scores were calculated (range 0-100, worst to best): measurement model, reliability, validity, responsiveness, interpretability, burden and alternative forms. Eight instruments and 57 manuscripts (2-15 per instrument) were identified. The Expanded Prostate Cancer Index Composite (EPIC) was the best rated (overall EMPRO score 83.1 points). Good results were also obtained by University of California Los Angeles-Prostate Cancer Index (UCLA-PCI), Patient-Oriented Prostate Utility Scale (PORPUS) and Prostate Cancer Quality of Life Instrument (PC-QoL) with 77.3, 70.5 and 64.8 points, respectively. These four instruments passed with distinction the validity and responsiveness evaluation. Insufficient reliability results were observed for UCLA-PCI and PORPUS. Current evidence supports the choice of EPIC, PORPUS or PC-QoL. Attribute-specific EMPRO results facilitate selecting the adequate instrument for every purpose. For longitudinal studies or clinical trials, where responsiveness is the priority, EPIC or PC-QoL should be considered. We recommend the PORPUS for economic evaluations because it allows cost-utility analysis, and EPIC short versions to minimize administration burden.

  2. Composite Overwrapped Pressure Vessels (COPV) Stress Rupture Test: Part 2. Part 2

    NASA Technical Reports Server (NTRS)

    Russell, Richard; Flynn, Howard; Forth, Scott; Greene, Nathanael; Kezirian, Michael; Varanauski, Don; Leifeste, Mark; Yoder, Tommy; Woodworth, Warren

    2010-01-01

    One of the major concerns for the aging Space Shuttle fleet is the stress rupture life of composite overwrapped pressure vessels (COPVs). Stress rupture life of a COPY has been defined as the minimum time during which the composite maintains structural integrity considering the combined effects of stress levels and time. To assist in the evaluation of the aging COPVs in the Orbiter fleet an analytical reliability model was developed. The actual data used to construct this model was from testing of COPVs constructed of similar, but not exactly same materials and pressure cycles as used on Orbiter vessels. Since no actual Orbiter COPV stress rupture data exists the Space Shuttle Program decided to run a stress rupture test to compare to model predictions. Due to availability of spares, the testing was unfortunately limited to one 40" vessel. The stress rupture test was performed at maximum operating pressure at an elevated temperature to accelerate aging. The test was performed in two phases. The first phase, 130 F, a moderately accelerated test designed to achieve the midpoint of the model predicted point reliability. A more aggressive second phase, performed at 160 F, was designed to determine if the test article will exceed the 95% confidence interval ofthe model. In phase 3, the vessel pressure was increased to above maximum operating pressure while maintaining the phase 2 temperature. After reaching enough effectives hours to reach the 99.99% confidence level of the model phase 4 testing began when the temperature was increased to greater than 170 F. The vessel was maintained at phase 4 conditions until it failed after over 3 million effect hours. This paper will discuss the results of this test, it's implications and possible follow-on testing.

  3. Environmental degradation of composites for marine structures: new materials and new applications

    PubMed Central

    2016-01-01

    This paper describes the influence of seawater ageing on composites used in a range of marine structures, from boats to tidal turbines. Accounting for environmental degradation is an essential element in the multi-scale modelling of composite materials but it requires reliable test data input. The traditional approach to account for ageing effects, based on testing samples after immersion for different periods, is evolving towards coupled studies involving strong interactions between water diffusion and mechanical loading. These can provide a more realistic estimation of long-term behaviour but still require some form of acceleration if useful data, for 20 year lifetimes or more, are to be obtained in a reasonable time. In order to validate extrapolations from short to long times, it is essential to understand the degradation mechanisms, so both physico-chemical and mechanical test data are required. Examples of results from some current studies on more environmentally friendly materials including bio-sourced composites will be described first. Then a case study for renewable marine energy applications will be discussed. In both cases, studies were performed first on coupons at the material level, then during structural testing and analysis of large components, in order to evaluate their long-term behaviour. This article is part of the themed issue ‘Multiscale modelling of the structural integrity of composite materials’. PMID:27242304

  4. Component-Level Tuning of Kinematic Features from Composite Therapist Impressions of Movement Quality

    PubMed Central

    Venkataraman, Vinay; Turaga, Pavan; Baran, Michael; Lehrer, Nicole; Du, Tingfang; Cheng, Long; Rikakis, Thanassis; Wolf, Steven L.

    2016-01-01

    In this paper, we propose a general framework for tuning component-level kinematic features using therapists’ overall impressions of movement quality, in the context of a Home-based Adaptive Mixed Reality Rehabilitation (HAMRR) system. We propose a linear combination of non-linear kinematic features to model wrist movement, and propose an approach to learn feature thresholds and weights using high-level labels of overall movement quality provided by a therapist. The kinematic features are chosen such that they correlate with the quality of wrist movements to clinical assessment scores. Further, the proposed features are designed to be reliably extracted from an inexpensive and portable motion capture system using a single reflective marker on the wrist. Using a dataset collected from ten stroke survivors, we demonstrate that the framework can be reliably used for movement quality assessment in HAMRR systems. The system is currently being deployed for large-scale evaluations, and will represent an increasingly important application area of motion capture and activity analysis. PMID:25438331

  5. The Face-Symbol Test and the Symbol-Digit Test are not reliable surrogates for the Paced Auditory Serial Addition Test in multiple sclerosis.

    PubMed

    Williams, J; O'Rourke, K; Hutchinson, M; Tubridy, N

    2006-10-01

    The Paced Auditory Serial Addition Test (PASAT) is the chosen task for cognitive assessment in the multiple sclerosis functional composite (MSFC) and a widely used task in neuropsychological studies of people with multiple sclerosis (MS), but is unpopular with patients. The Face-Symbol Test (FST) and Symbol-Digit Tests (SDT) are alternative methods of cognitive testing in MS, which are easily administered and patient-friendly. In order to evaluate the potential of the FST as a possible surrogate for the PASAT, we directly compared the FST to the PASAT and the SDT in a cohort of 50 MS patients with varying levels of disability. There was significant correlation between SDT and FST scores (Spearman's rho 0.80, 95% CI 0.66-0.88), R(2) 65%, with moderate inter-test agreement (k =0.52). In contrast, SDT and FST scores were less predictive of PASAT scores. We concluded that neither the FST nor SDT are reliable surrogates for the PASAT.

  6. Stochastic-Strength-Based Damage Simulation Tool for Ceramic Matrix and Polymer Matrix Composite Structures

    NASA Technical Reports Server (NTRS)

    Nemeth, Noel N.; Bednarcyk, Brett A.; Pineda, Evan J.; Walton, Owen J.; Arnold, Steven M.

    2016-01-01

    Stochastic-based, discrete-event progressive damage simulations of ceramic-matrix composite and polymer matrix composite material structures have been enabled through the development of a unique multiscale modeling tool. This effort involves coupling three independently developed software programs: (1) the Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC), (2) the Ceramics Analysis and Reliability Evaluation of Structures Life Prediction Program (CARES/ Life), and (3) the Abaqus finite element analysis (FEA) program. MAC/GMC contributes multiscale modeling capabilities and micromechanics relations to determine stresses and deformations at the microscale of the composite material repeating unit cell (RUC). CARES/Life contributes statistical multiaxial failure criteria that can be applied to the individual brittle-material constituents of the RUC. Abaqus is used at the global scale to model the overall composite structure. An Abaqus user-defined material (UMAT) interface, referred to here as "FEAMAC/CARES," was developed that enables MAC/GMC and CARES/Life to operate seamlessly with the Abaqus FEA code. For each FEAMAC/CARES simulation trial, the stochastic nature of brittle material strength results in random, discrete damage events, which incrementally progress and lead to ultimate structural failure. This report describes the FEAMAC/CARES methodology and discusses examples that illustrate the performance of the tool. A comprehensive example problem, simulating the progressive damage of laminated ceramic matrix composites under various off-axis loading conditions and including a double notched tensile specimen geometry, is described in a separate report.

  7. Cryopyrin-associated periodic syndromes: development of a patient-reported outcomes instrument to assess the pattern and severity of clinical disease activity.

    PubMed

    Hoffman, Hal M; Wolfe, Frederick; Belomestnov, Pavel; Mellis, Scott J

    2008-09-01

    Development of an instrument for characterization of symptom patterns and severity in patients with cryopyrin-associated periodic syndromes (CAPS). Two generations of daily health assessment forms (DHAFs) were evaluated in this study. The first-generation DHAF queried 11 symptoms. Analyses of results obtained with that instrument identified five symptoms included in a revised second-generation DHAF that was tested for internal consistency and test-retest reliability. This DHAF was also assessed during the initial portion of a phase 3 clinical study of CAPS treatment. Forty-eight CAPS patients provided data for the first-generation DHAFs. Five symptoms (rash, fever, joint pain, eye redness/pain, and fatigue) were included in the revised second-generation DHAF. Symptom severity was highly variable during all study phases with as many as 89% of patients reporting at least one symptom flare, and percentages of days with flares reaching 58% during evaluation of the second-generation instrument. Mean composite key symptom scores (KSSs) computed during evaluation of the second-generation DHAF correlated well with Physician's Global Assessment of Disease Activity (r=0.91, p<0.0001) and patient reports of limitations of daily activities (r=0.68, p<0.0001). Test-retest reliability and Cronbach's alpha's were high (0.93 and 0.94, respectively) for the second-generation DHAF. Further evaluation of this DHAF during a baseline period and placebo treatment in a phase 3 clinical study of CAPS patients indicated strong correlations between baseline KSS and Physician's Global Assessment of Disease Activity. Cronbach's alpha's at baseline and test-retest reliability were also high. Potentially important study limitations include small sample size, the lack of a standard tool for CAPS symptom assessment against which to validate the DHAF, and no assessment of the instrument's responsivity to CAPS therapy. The DHAF is a new instrument that may be useful for capturing symptom patterns and severity in CAPS patients and monitoring responses to therapies for these conditions.

  8. Trace metal speciation in natural waters: Computational vs. analytical

    USGS Publications Warehouse

    Nordstrom, D. Kirk

    1996-01-01

    Improvements in the field sampling, preservation, and determination of trace metals in natural waters have made many analyses more reliable and less affected by contamination. The speciation of trace metals, however, remains controversial. Chemical model speciation calculations do not necessarily agree with voltammetric, ion exchange, potentiometric, or other analytical speciation techniques. When metal-organic complexes are important, model calculations are not usually helpful and on-site analytical separations are essential. Many analytical speciation techniques have serious interferences and only work well for a limited subset of water types and compositions. A combined approach to the evaluation of speciation could greatly reduce these uncertainties. The approach proposed would be to (1) compare and contrast different analytical techniques with each other and with computed speciation, (2) compare computed trace metal speciation with reliable measurements of solubility, potentiometry, and mean activity coefficients, and (3) compare different model calculations with each other for the same set of water analyses, especially where supplementary data on speciation already exist. A comparison and critique of analytical with chemical model speciation for a range of water samples would delineate the useful range and limitations of these different approaches to speciation. Both model calculations and analytical determinations have useful and different constraints on the range of possible speciation such that they can provide much better insight into speciation when used together. Major discrepancies in the thermodynamic databases of speciation models can be evaluated with the aid of analytical speciation, and when the thermodynamic models are highly consistent and reliable, the sources of error in the analytical speciation can be evaluated. Major thermodynamic discrepancies also can be evaluated by simulating solubility and activity coefficient data and testing various chemical models for their range of applicability. Until a comparative approach such as this is taken, trace metal speciation will remain highly uncertain and controversial.

  9. Improvement and evaluation of thermal, electrical, sealing and mechanical contacts, and their interface materials

    NASA Astrophysics Data System (ADS)

    Luo, Xiangcheng

    Material contacts, including thermal, electrical, seating (fluid sealing and electromagnetic sealing) and mechanical (pressure) contacts, together with their interface materials, were, evaluated, and in some cases, improved beyond the state of the art. The evaluation involved the use of thermal, electrical and mechanical methods. For thermal contacts, this work evaluated and improved the heat transfer efficiency between two contacting components by developing various thermal interface pastes. Sodium silicate based thermal pastes (with boron nitride particles as the thermally conductive filler) as well as polyethylene glycol (PEG) based thermal pastes were developed and evaluated. The optimum volume fractions of BN in sodium silicate based pastes and PEG based pastes were 16% and 18% respectively. The contribution of Li+ ions to the thermal contact conductance in the PEG-based paste was confirmed. For electrical contacts, the relationship between the mechanical reliability and electrical reliability of solder/copper and silver-epoxy/copper joints was addressed. Mechanical pull-out testing was conducted on solder/copper and silver-epoxy/copper joints, while the contact electrical resistivity was measured. Cleansing of the copper surface was more effective for the reliability of silver-epoxy/copper joint than that of solder/copper joint. For sealing contacts, this work evaluated flexible graphite as an electromagnetic shielding gasket material. Flexible graphite was found to be at least comparable to conductive filled silicone (the state of the art) in terms of the shielding effectiveness. The conformability of flexible graphite with its mating metal surface under repeated compression was characterized by monitoring the contact electrical resistance, as the conformability is important to both electromagnetic scaling and fluid waling using flexible graphite. For mechanical contacts, this work focused on the correlation of the interface structure (such as elastic/plastic deformation, oxidation, strain hardening, passive layer damage, fracture, etc.) with the electrical contact resistance, which was measured in real time for contacts under dynamic compression, thus allowing both reversible and irreversible changes to be observed. The materials studied included metals (carbon steel, stainless steel, aluminum and copper), carbon fiber reinforced polymer-matrix composite (nylon-6), ceramic (mortar) and graphite, due to their relevance to fastening, concrete structures, electric brushes and electrical pressure contacts.

  10. Advances in Micromechanics Modeling of Composites Structures for Structural Health Monitoring

    NASA Astrophysics Data System (ADS)

    Moncada, Albert

    Although high performance, light-weight composites are increasingly being used in applications ranging from aircraft, rotorcraft, weapon systems and ground vehicles, the assurance of structural reliability remains a critical issue. In composites, damage is absorbed through various fracture processes, including fiber failure, matrix cracking and delamination. An important element in achieving reliable composite systems is a strong capability of assessing and inspecting physical damage of critical structural components. Installation of a robust Structural Health Monitoring (SHM) system would be very valuable in detecting the onset of composite failure. A number of major issues still require serious attention in connection with the research and development aspects of sensor-integrated reliable SHM systems for composite structures. In particular, the sensitivity of currently available sensor systems does not allow detection of micro level damage; this limits the capability of data driven SHM systems. As a fundamental layer in SHM, modeling can provide in-depth information on material and structural behavior for sensing and detection, as well as data for learning algorithms. This dissertation focuses on the development of a multiscale analysis framework, which is used to detect various forms of damage in complex composite structures. A generalized method of cells based micromechanics analysis, as implemented in NASA's MAC/GMC code, is used for the micro-level analysis. First, a baseline study of MAC/GMC is performed to determine the governing failure theories that best capture the damage progression. The deficiencies associated with various layups and loading conditions are addressed. In most micromechanics analysis, a representative unit cell (RUC) with a common fiber packing arrangement is used. The effect of variation in this arrangement within the RUC has been studied and results indicate this variation influences the macro-scale effective material properties and failure stresses. The developed model has been used to simulate impact damage in a composite beam and an airfoil structure. The model data was verified through active interrogation using piezoelectric sensors. The multiscale model was further extended to develop a coupled damage and wave attenuation model, which was used to study different damage states such as fiber-matrix debonding in composite structures with surface bonded piezoelectric sensors.

  11. Composite membrane with integral rim

    DOEpatents

    Routkevitch, Dmitri; Polyakov, Oleg G

    2015-01-27

    Composite membranes that are adapted for separation, purification, filtration, analysis, reaction and sensing. The composite membranes can include a porous support structure having elongate pore channels extending through the support structure. The composite membrane also includes an active layer comprising an active layer material, where the active layer material is completely disposed within the pore channels between the surfaces of the support structure. The active layer is intimately integrated within the support structure, thus enabling great robustness, reliability, resistance to mechanical stress and thermal cycling, and high selectivity. Methods for the fabrication of composite membranes are also provided.

  12. A base-metal conductor system for silicon solar cells

    NASA Technical Reports Server (NTRS)

    Coleman, M. G.; Pryor, R. A.; Sparks, T. G.

    1980-01-01

    Solder, copper, and silver are evaluated as conductor layer metals for silicon solar cell metallization on the basis of metal price stability and reliability under operating conditions. Due to its properties and cost, copper becomes an attractive candidate for the conductor layer. It is shown that nickel operates as an excellent diffusion barrier between copper and silicon while simultaneously serving as an electrical contact and mechanical contact to silicon. The nickel-copper system may be applied to the silicon by plating techniques utilizing a variety of plating bath compositions. Solar cells having excellent current-voltage characteristics are fabricated to demonstrate the nickel-copper metallization system.

  13. Identification of Aeromonas isolates by matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    PubMed

    Lamy, Brigitte; Kodjo, Angeli; Laurent, Frédéric

    2011-09-01

    We evaluated the accuracy of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for identifying aeromonads with an extraction procedure. Genus-level accuracy was 100%. Compared to rpoB gene sequencing, species-level accuracy was 90.6% (29/32) for type and reference strains and 91.4% for a collection of 139 clinical and environmental isolates, making this system one of the most accurate and rapid methods for phenotypic identification. The reliability of this technique was very promising, although some improvements in database composition, taxonomy, and discriminatory power are needed. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Effect of Cyclic Thermo-Mechanical Loads on Fatigue Reliability in Polymer Matrix Composites

    NASA Technical Reports Server (NTRS)

    Shah, A. R.; Murthy, P. L. N.; Chamis, C. C.

    1996-01-01

    A methodology to compute probabilistic fatigue life of polymer matrix laminated composites has been developed and demonstrated. Matrix degradation effects caused by long term environmental exposure and mechanical/thermal cyclic loads are accounted for in the simulation process. A unified time-temperature-stress dependent multi-factor interaction relationship developed at NASA Lewis Research Center has been used to model the degradation/aging of material properties due to cyclic loads. The fast probability integration method is used to compute probabilistic distribution of response. Sensitivities of fatigue life reliability to uncertainties in the primitive random variables (e.g., constituent properties, fiber volume ratio, void volume ratio, ply thickness, etc.) computed and their significance in the reliability- based design for maximum life is discussed. The effect of variation in the thermal cyclic loads on the fatigue reliability for a (0/+/- 45/90)(sub s) graphite/epoxy laminate with a ply thickness of 0.127 mm, with respect to impending failure modes has been studied. The results show that, at low mechanical cyclic loads and low thermal cyclic amplitudes, fatigue life for 0.999 reliability is most sensitive to matrix compressive strength, matrix modulus, thermal expansion coefficient, and ply thickness. Whereas at high mechanical cyclic loads and high thermal cyclic amplitudes, fatigue life at 0.999 reliability is more sensitive to the shear strength of matrix, longitudinal fiber modulus, matrix modulus, and ply thickness.

  15. Evaluation of Reliability Coefficients for Two-Level Models via Latent Variable Analysis

    ERIC Educational Resources Information Center

    Raykov, Tenko; Penev, Spiridon

    2010-01-01

    A latent variable analysis procedure for evaluation of reliability coefficients for 2-level models is outlined. The method provides point and interval estimates of group means' reliability, overall reliability of means, and conditional reliability. In addition, the approach can be used to test simple hypotheses about these parameters. The…

  16. Measuring cognitive change with ImPACT: the aggregate baseline approach.

    PubMed

    Bruce, Jared M; Echemendia, Ruben J; Meeuwisse, Willem; Hutchison, Michael G; Aubry, Mark; Comper, Paul

    2017-11-01

    The Immediate Post-Concussion Assessment and Cognitive Test (ImPACT) is commonly used to assess baseline and post-injury cognition among athletes in North America. Despite this, several studies have questioned the reliability of ImPACT when given at intervals employed in clinical practice. Poor test-retest reliability reduces test sensitivity to cognitive decline, increasing the likelihood that concussed athletes will be returned to play prematurely. We recently showed that the reliability of ImPACT can be increased when using a new composite structure and the aggregate of two baselines to predict subsequent performance. The purpose of the present study was to confirm our previous findings and determine whether the addition of a third baseline would further increase the test-retest reliability of ImPACT. Data from 97 English speaking professional hockey players who had received at least 4 ImPACT baseline evaluations were extracted from a National Hockey League Concussion Program database. Linear regression was used to determine whether each of the first three testing sessions accounted for unique variance in the fourth testing session. Results confirmed that the aggregate baseline approach improves the psychometric properties of ImPACT, with most indices demonstrating adequate or better test-retest reliability for clinical use. The aggregate baseline approach provides a modest clinical benefit when recent baselines are available - and a more substantial benefit when compared to approaches that obtain baseline measures only once during the course of a multi-year playing career. Pending confirmation in diverse samples, neuropsychologists are encouraged to use the aggregate baseline approach to best quantify cognitive change following sports concussion.

  17. Reliability Evaluation of Machine Center Components Based on Cascading Failure Analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Ying-Zhi; Liu, Jin-Tong; Shen, Gui-Xiang; Long, Zhe; Sun, Shu-Guang

    2017-07-01

    In order to rectify the problems that the component reliability model exhibits deviation, and the evaluation result is low due to the overlook of failure propagation in traditional reliability evaluation of machine center components, a new reliability evaluation method based on cascading failure analysis and the failure influenced degree assessment is proposed. A direct graph model of cascading failure among components is established according to cascading failure mechanism analysis and graph theory. The failure influenced degrees of the system components are assessed by the adjacency matrix and its transposition, combined with the Pagerank algorithm. Based on the comprehensive failure probability function and total probability formula, the inherent failure probability function is determined to realize the reliability evaluation of the system components. Finally, the method is applied to a machine center, it shows the following: 1) The reliability evaluation values of the proposed method are at least 2.5% higher than those of the traditional method; 2) The difference between the comprehensive and inherent reliability of the system component presents a positive correlation with the failure influenced degree of the system component, which provides a theoretical basis for reliability allocation of machine center system.

  18. Composite Reliability of a Workplace-Based Assessment Toolbox for Postgraduate Medical Education

    ERIC Educational Resources Information Center

    Moonen-van Loon, J. M. W.; Overeem, K.; Donkers, H. H. L. M.; van der Vleuten, C. P. M.; Driessen, E. W.

    2013-01-01

    In recent years, postgraduate assessment programmes around the world have embraced workplace-based assessment (WBA) and its related tools. Despite their widespread use, results of studies on the validity and reliability of these tools have been variable. Although in many countries decisions about residents' continuation of training and…

  19. Probabilistic and structural reliability analysis of laminated composite structures based on the IPACS code

    NASA Technical Reports Server (NTRS)

    Sobel, Larry; Buttitta, Claudio; Suarez, James

    1993-01-01

    Probabilistic predictions based on the Integrated Probabilistic Assessment of Composite Structures (IPACS) code are presented for the material and structural response of unnotched and notched, 1M6/3501-6 Gr/Ep laminates. Comparisons of predicted and measured modulus and strength distributions are given for unnotched unidirectional, cross-ply, and quasi-isotropic laminates. The predicted modulus distributions were found to correlate well with the test results for all three unnotched laminates. Correlations of strength distributions for the unnotched laminates are judged good for the unidirectional laminate and fair for the cross-ply laminate, whereas the strength correlation for the quasi-isotropic laminate is deficient because IPACS did not yet have a progressive failure capability. The paper also presents probabilistic and structural reliability analysis predictions for the strain concentration factor (SCF) for an open-hole, quasi-isotropic laminate subjected to longitudinal tension. A special procedure was developed to adapt IPACS for the structural reliability analysis. The reliability results show the importance of identifying the most significant random variables upon which the SCF depends, and of having accurate scatter values for these variables.

  20. A Comparison of Various Stress Rupture Life Models for Orbiter Composite Pressure Vessels and Confidence Intervals

    NASA Technical Reports Server (NTRS)

    Grimes-Ledesma, Lorie; Murthy, Pappu L. N.; Phoenix, S. Leigh; Glaser, Ronald

    2007-01-01

    In conjunction with a recent NASA Engineering and Safety Center (NESC) investigation of flight worthiness of Kevlar Overwrapped Composite Pressure Vessels (COPVs) on board the Orbiter, two stress rupture life prediction models were proposed independently by Phoenix and by Glaser. In this paper, the use of these models to determine the system reliability of 24 COPVs currently in service on board the Orbiter is discussed. The models are briefly described, compared to each other, and model parameters and parameter uncertainties are also reviewed to understand confidence in reliability estimation as well as the sensitivities of these parameters in influencing overall predicted reliability levels. Differences and similarities in the various models will be compared via stress rupture reliability curves (stress ratio vs. lifetime plots). Also outlined will be the differences in the underlying model premises, and predictive outcomes. Sources of error and sensitivities in the models will be examined and discussed based on sensitivity analysis and confidence interval determination. Confidence interval results and their implications will be discussed for the models by Phoenix and Glaser.

  1. Development of Composite PCMs by Incorporation of Paraffin into Various Building Materials

    PubMed Central

    Memon, Shazim Ali; Liao, Wenyu; Yang, Shuqing; Cui, Hongzhi; Shah, Syed Farasat Ali

    2015-01-01

    In this research, we focused on the development of composite phase-change materials (CPCMs) by incorporation of a paraffin through vacuum impregnation in widely used building materials (Kaolin and ground granulated blast-furnace slag (GGBS)). The composite PCMs were characterized using environmental scanning electron microscopy (ESEM), Fourier transform infrared spectroscopy (FT-IR), differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) techniques. Moreover, thermal performance of cement paste composite PCM panels was evaluated using a self-designed heating system. Test results showed that the maximum percentage of paraffin retained by Kaolin and GGBS was found to be 18% and 9%, respectively. FT-IR results show that CPCMs are chemically compatible. The phase-change temperatures of CPCMs were in the human comfort zone, and they possessed considerable latent-heat storage capacity. TGA results showed that CPCMs are thermally stable, and they did not show any sign of degradation below 150 °C. From thermal cycling tests, it was revealed that the CPCMs are thermally reliable. Thermal performance tests showed that in comparison to the control room model, the room models prepared with CPCMs reduced both the temperature fluctuations and maximum indoor center temperature. Therefore, the prepared CPCMs have some potential in reducing peak loads in buildings when applied to building facade. PMID:28787953

  2. Revealing the nature of morphological changes in carbon nanotube-polymer saturable absorber under high-power laser irradiation.

    PubMed

    Chernysheva, Maria; Araimi, Mohammed Al; Rance, Graham A; Weston, Nicola J; Shi, Baogui; Saied, Sayah; Sullivan, John L; Marsh, Nicholas; Rozhin, Aleksey

    2018-05-10

    Composites of single-walled carbon nanotubes (SWNTs) and water-soluble polymers (WSP) are the focus of significant worldwide research due to a number of applications in biotechnology and photonics, particularly for ultrashort pulse generation. Despite the unique possibility of constructing non-linear optical SWNT-WSP composites with controlled optical properties, their thermal degradation threshold and limit of operational power remain unexplored. In this study, we discover the nature of the SWNT-polyvinyl alcohol (PVA) film thermal degradation and evaluate the modification of the composite properties under continuous high-power ultrashort pulse laser operation. Using high-precision optical microscopy and micro-Raman spectroscopy, we have examined SWNT-PVA films before and after continuous laser radiation exposure (up to 40 hours) with a maximum optical fluence of 2.3 mJ·cm -2 . We demonstrate that high-intensity laser radiation results in measurable changes in the composition and morphology of the SWNT-PVA film due to efficient heat transfer from SWNTs to the polymer matrix. The saturable absorber modification does not affect the laser operational performance. We anticipate our work to be a starting point for more sophisticated research aimed at the enhancement of SWNT-PVA films fabrication for their operation as reliable saturable absorbers in high-power ultrafast lasers.

  3. Degradation of ticarcillin by subcritial water oxidation method: Application of response surface methodology and artificial neural network modeling.

    PubMed

    Yabalak, Erdal

    2018-05-18

    This study was performed to investigate the mineralization of ticarcillin in the artificially prepared aqueous solution presenting ticarcillin contaminated waters, which constitute a serious problem for human health. 81.99% of total organic carbon removal, 79.65% of chemical oxygen demand removal, and 94.35% of ticarcillin removal were achieved by using eco-friendly, time-saving, powerful and easy-applying, subcritical water oxidation method in the presence of a safe-to-use oxidizing agent, hydrogen peroxide. Central composite design, which belongs to the response surface methodology, was applied to design the degradation experiments, to optimize the methods, to evaluate the effects of the system variables, namely, temperature, hydrogen peroxide concentration, and treatment time, on the responses. In addition, theoretical equations were proposed in each removal processes. ANOVA tests were utilized to evaluate the reliability of the performed models. F values of 245.79, 88.74, and 48.22 were found for total organic carbon removal, chemical oxygen demand removal, and ticarcillin removal, respectively. Moreover, artificial neural network modeling was applied to estimate the response in each case and its prediction and optimizing performance was statistically examined and compared to the performance of central composite design.

  4. A Multiuser Manufacturing Resource Service Composition Method Based on the Bees Algorithm

    PubMed Central

    Xie, Yongquan; Zhou, Zude; Pham, Duc Truong; Xu, Wenjun; Ji, Chunqian

    2015-01-01

    In order to realize an optimal resource service allocation in current open and service-oriented manufacturing model, multiuser resource service composition (RSC) is modeled as a combinational and constrained multiobjective problem. The model takes into account both subjective and objective quality of service (QoS) properties as representatives to evaluate a solution. The QoS properties aggregation and evaluation techniques are based on existing researches. The basic Bees Algorithm is tailored for finding a near optimal solution to the model, since the basic version is only proposed to find a desired solution in continuous domain and thus not suitable for solving the problem modeled in our study. Particular rules are designed for handling the constraints and finding Pareto optimality. In addition, the established model introduces a trusted service set to each user so that the algorithm could start by searching in the neighbor of more reliable service chains (known as seeds) than those randomly generated. The advantages of these techniques are validated by experiments in terms of success rate, searching speed, ability of avoiding ingenuity, and so forth. The results demonstrate the effectiveness of the proposed method in handling multiuser RSC problems. PMID:26339232

  5. Developing an oropharyngeal cancer (OPC) knowledge and behaviors survey.

    PubMed

    Dodd, Virginia J; Riley Iii, Joseph L; Logan, Henrietta L

    2012-09-01

    To use the community participation research model to (1) develop a survey assessing knowledge about mouth and throat cancer and (2) field test and establish test-retest reliability with newly developed instrument. Cognitive interviews with primarily rural African American adults to assess their perception and interpretation of survey items. Test-retest reliability was established with a racially diverse rural population. Test-retest reliabilities ranged from .79 to .40 for screening awareness and .74 to .19 for knowledge. Coefficients increased for composite scores. Community participation methodology provided a culturally appropriate survey instrument that demonstrated acceptable levels of reliability.

  6. A New Tool for Nutrition App Quality Evaluation (AQEL): Development, Validation, and Reliability Testing

    PubMed Central

    Huang, Wenhao; Chapman-Novakofski, Karen M

    2017-01-01

    Background The extensive availability and increasing use of mobile apps for nutrition-based health interventions makes evaluation of the quality of these apps crucial for integration of apps into nutritional counseling. Objective The goal of this research was the development, validation, and reliability testing of the app quality evaluation (AQEL) tool, an instrument for evaluating apps’ educational quality and technical functionality. Methods Items for evaluating app quality were adapted from website evaluations, with additional items added to evaluate the specific characteristics of apps, resulting in 79 initial items. Expert panels of nutrition and technology professionals and app users reviewed items for face and content validation. After recommended revisions, nutrition experts completed a second AQEL review to ensure clarity. On the basis of 150 sets of responses using the revised AQEL, principal component analysis was completed, reducing AQEL into 5 factors that underwent reliability testing, including internal consistency, split-half reliability, test-retest reliability, and interrater reliability (IRR). Two additional modifiable constructs for evaluating apps based on the age and needs of the target audience as selected by the evaluator were also tested for construct reliability. IRR testing using intraclass correlations (ICC) with all 7 constructs was conducted, with 15 dietitians evaluating one app. Results Development and validation resulted in the 51-item AQEL. These were reduced to 25 items in 5 factors after principal component analysis, plus 9 modifiable items in two constructs that were not included in principal component analysis. Internal consistency and split-half reliability of the following constructs derived from principal components analysis was good (Cronbach alpha >.80, Spearman-Brown coefficient >.80): behavior change potential, support of knowledge acquisition, app function, and skill development. App purpose split half-reliability was .65. Test-retest reliability showed no significant change over time (P>.05) for all but skill development (P=.001). Construct reliability was good for items assessing age appropriateness of apps for children, teens, and a general audience. In addition, construct reliability was acceptable for assessing app appropriateness for various target audiences (Cronbach alpha >.70). For the 5 main factors, ICC (1,k) was >.80, with a P value of <.05. When 15 nutrition professionals evaluated one app, ICC (2,15) was .98, with a P value of <.001 for all 7 constructs when the modifiable items were specified for adults seeking weight loss support. Conclusions Our preliminary effort shows that AQEL is a valid, reliable instrument for evaluating nutrition apps’ qualities for clinical interventions by nutrition clinicians, educators, and researchers. Further efforts in validating AQEL in various contexts are needed. PMID:29079554

  7. Reliability Evaluation and Improvement Approach of Chemical Production Man - Machine - Environment System

    NASA Astrophysics Data System (ADS)

    Miao, Yongchun; Kang, Rongxue; Chen, Xuefeng

    2017-12-01

    In recent years, with the gradual extension of reliability research, the study of production system reliability has become the hot topic in various industries. Man-machine-environment system is a complex system composed of human factors, machinery equipment and environment. The reliability of individual factor must be analyzed in order to gradually transit to the research of three-factor reliability. Meanwhile, the dynamic relationship among man-machine-environment should be considered to establish an effective blurry evaluation mechanism to truly and effectively analyze the reliability of such systems. In this paper, based on the system engineering, fuzzy theory, reliability theory, human error, environmental impact and machinery equipment failure theory, the reliabilities of human factor, machinery equipment and environment of some chemical production system were studied by the method of fuzzy evaluation. At last, the reliability of man-machine-environment system was calculated to obtain the weighted result, which indicated that the reliability value of this chemical production system was 86.29. Through the given evaluation domain it can be seen that the reliability of man-machine-environment integrated system is in a good status, and the effective measures for further improvement were proposed according to the fuzzy calculation results.

  8. The influence of validity criteria on Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) test-retest reliability among high school athletes.

    PubMed

    Brett, Benjamin L; Solomon, Gary S

    2017-04-01

    Research findings to date on the stability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) Composite scores have been inconsistent, requiring further investigation. The use of test validity criteria across these studies also has been inconsistent. Using multiple measures of stability, we examined test-retest reliability of repeated ImPACT baseline assessments in high school athletes across various validity criteria reported in previous studies. A total of 1146 high school athletes completed baseline cognitive testing using the online ImPACT test battery at two time periods of approximately two-year intervals. No participant sustained a concussion between assessments. Five forms of validity criteria used in previous test-retest studies were applied to the data, and differences in reliability were compared. Intraclass correlation coefficients (ICCs) ranged in composite scores from .47 (95% confidence interval, CI [.38, .54]) to .83 (95% CI [.81, .85]) and showed little change across a two-year interval for all five sets of validity criteria. Regression based methods (RBMs) examining the test-retest stability demonstrated a lack of significant change in composite scores across the two-year interval for all forms of validity criteria, with no cases falling outside the expected range of 90% confidence intervals. The application of more stringent validity criteria does not alter test-retest reliability, nor does it account for some of the variation observed across previously performed studies. As such, use of the ImPACT manual validity criteria should be utilized in the determination of test validity and in the individualized approach to concussion management. Potential future efforts to improve test-retest reliability are discussed.

  9. Explosive scabbling of structural materials

    DOEpatents

    Bickes, Jr., Robert W.; Bonzon, Lloyd L.

    2002-01-01

    A new approach to scabbling of surfaces of structural materials is disclosed. A layer of mildly energetic explosive composition is applied to the surface to be scabbled. The explosive composition is then detonated, rubbleizing the surface. Explosive compositions used must sustain a detonation front along the surface to which it is applied and conform closely to the surface being scabbled. Suitable explosive compositions exist which are stable under handling, easy to apply, easy to transport, have limited toxicity, and can be reliably detonated using conventional techniques.

  10. Micromechanical analysis of thermo-inelastic multiphase short-fiber composites

    NASA Technical Reports Server (NTRS)

    Aboudi, Jacob

    1994-01-01

    A micromechanical formulation is presented for the prediction of the overall thermo-inelastic behavior of multiphase composites which consist of short fibers. The analysis is an extension of the generalized method of cells that was previously derived for inelastic composites with continuous fibers, and the reliability of which was critically examined in several situations. The resulting three dimensional formulation is extremely general, wherein the analysis of thermo-inelastic composites with continuous fibers as well as particulate and porous inelastic materials are merely special cases.

  11. Two-year Test-Retest Reliability in High School Athletes Using the Four- and Two-Factor ImPACT Composite Structures: The Effects of Learning Disorders and Headache/Migraine Treatment History.

    PubMed

    Brett, Benjamin L; Solomon, Gary S; Hill, Jennifer; Schatz, Philip

    2018-03-01

    This study examined the test-retest reliability of the four- and two-factor structures (i.e., Memory and Speed) of ImPACT over a 2-year interval across multiple groups with premorbid conditions, including those with a history of special education or learning disorders (LD; n = 114), treatment history for headache/migraine (n = 81), and a control group (n = 792). Nine hundred and eighty seven high school athletes completed baseline testing using online ImPACT across a 2-year interval. Paired-samples t-tests documented improvement from initial to follow-up assessments. Test stability was examined using Regression-based measures (RBM) and Reliable change indices (RCI). Reliability was examined using intraclass correlation coefficients (ICC). Significant improvement on all four composites were observed for the control group over a 2-year interval; whereas significant differences were observed only on Visual Motor Speed for the LD and headache/migraine treatment history groups. ICCs ranges were similar across groups and greater or comparable reliability was observed for the two-factor structure on Memory (0.67-0.73) and Speed (0.76-0.78) composites. RCIs and RBMs demonstrated stability for the four- and two-factor structures, with few cases falling outside the range of expected change within a healthy sample at the 90% and 95% CIs. Typical practices of obtaining new baselines every 2 years in the high school population can be applied to athletes with a history of special education or LD and headache/migraine treatment. The two-factor structure has potential to increase test-retest reliability. Further research regarding clinical utility is needed. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Improving Reliability of a Residency Interview Process

    PubMed Central

    Serres, Michelle L.; Gundrum, Todd E.

    2013-01-01

    Objective. To improve the reliability and discrimination of a pharmacy resident interview evaluation form, and thereby improve the reliability of the interview process. Methods. In phase 1 of the study, authors used a Many-Facet Rasch Measurement model to optimize an existing evaluation form for reliability and discrimination. In phase 2, interviewer pairs used the modified evaluation form within 4 separate interview stations. In phase 3, 8 interviewers individually-evaluated each candidate in one-on-one interviews. Results. In phase 1, the evaluation form had a reliability of 0.98 with person separation of 6.56; reproducibly, the form separated applicants into 6 distinct groups. Using that form in phase 2 and 3, our largest variation source was candidates, while content specificity was the next largest variation source. The phase 2 g-coefficient was 0.787, while confirmatory phase 3 was 0.922. Process reliability improved with more stations despite fewer interviewers per station—impact of content specificity was greatly reduced with more interview stations. Conclusion. A more reliable, discriminating evaluation form was developed to evaluate candidates during resident interviews, and a process was designed that reduced the impact from content specificity. PMID:24159209

  13. Indices of Paraspinal Muscles Degeneration: Reliability and Association With Facet Joint Osteoarthritis: Feasibility Study.

    PubMed

    Kalichman, Leonid; Klindukhov, Alexander; Li, Ling; Linov, Lina

    2016-11-01

    A reliability and cross-sectional observational study. To introduce a scoring system for visible fat infiltration in paraspinal muscles; to evaluate intertester and intratester reliability of this system and its relationship with indices of muscle density; to evaluate the association between indices of paraspinal muscle degeneration and facet joint osteoarthritis. Current evidence suggests that the paraspinal muscles degeneration is associated with low back pain, facet joint osteoarthritis, spondylolisthesis, and degenerative disc disease. However, the evaluation of paraspinal muscles on computed tomography is not radiological routine, probably because of absence of simple and reliable indices of paraspinal degeneration. One hundred fifty consecutive computed tomography scans of the lower back (N=75) or abdomen (N=75) were evaluated. Mean radiographic density (in Hounsfield units) and SD of the density of multifidus and erector spinae were evaluated at the L4-L5 spinal level. A new index of muscle degeneration, radiographic density ratio=muscle density/SD of density, was calculated. To evaluate the visible fat infiltration in paraspinal muscles, we proposed a 3-graded scoring system. The prevalence of facet joint osteoarthritis was also evaluated. Intraclass correlation and κ statistics were used to evaluate inter-rater and intra-rater reliability. Logistic regression examined the association between paraspinal muscle indices and facet joint osteoarthritis. Intra-rater reliability for fat infiltration score (κ) ranged between 0.87 and 0.92; inter-rater reliability between 0.70 and 0.81. Intra-rater reliability (intraclass correlation) for mean density of paraspinal muscles ranged between 0.96 and 0.99, inter-rater reliability between 0.95 and 0.99; SD intra-rater reliability ranged between 0.82 and 0.91, inter-rater reliability between 0.80 and 0.89. Significant associations (P<0.01) were found between facet joint osteoarthritis, fat infiltration score, and radiographic density ratio. Two suggested indices of paraspinal muscle degeneration showed excellent reliability and were significantly associated with facet joint osteoarthritis. Additional studies are needed to evaluate the associations with other spinal degeneration features and low back pain.

  14. Properties Of Carbon/Carbon and Carbon/Phenolic Composites

    NASA Technical Reports Server (NTRS)

    Mathis, John R.; Canfield, A. R.

    1993-01-01

    Report presents data on physical properties of carbon-fiber-reinforced carbon-matrix and phenolic-matrix composite materials. Based on tests conducted on panels, cylinders, blocks, and formed parts. Data used by designers to analyze thermal-response and stress levels and develop structural systems ensuring high reliability at minimum weight.

  15. Validity and Reliability of Assessing Body Composition Using a Mobile Application.

    PubMed

    Macdonald, Elizabeth Z; Vehrs, Pat R; Fellingham, Gilbert W; Eggett, Dennis; George, James D; Hager, Ronald

    2017-12-01

    The purpose of this study was to determine the validity and reliability of the LeanScreen (LS) mobile application that estimates percent body fat (%BF) using estimates of circumferences from photographs. The %BF of 148 weight-stable adults was estimated once using dual-energy x-ray absorptiometry (DXA). Each of two administrators assessed the %BF of each subject twice using the LS app and manually measured circumferences. A mixed-model ANOVA and Bland-Altman analyses were used to compare the estimates of %BF obtained from each method. Interrater and intrarater reliabilities values were determined using multiple measurements taken by each of the two administrators. The LS app and manually measured circumferences significantly underestimated (P < 0.05) the %BF determined using DXA by an average of -3.26 and -4.82 %BF, respectively. The LS app (6.99 %BF) and manually measured circumferences (6.76 %BF) had large limits of agreement. All interrater and intrarater reliability coefficients of estimates of %BF using the LS app and manually measured circumferences exceeded 0.99. The estimates of %BF from manually measured circumferences and the LS app were highly reliable. However, these field measures are not currently recommended for the assessment of body composition because of significant bias and large limits of agreements.

  16. Realizing Crack Diagnosing and Self‐Healing by Electricity with a Dynamic Crosslinked Flexible Polyurethane Composite

    PubMed Central

    Pu, Wuli; Fu, Daihua; Wang, Zhanhua; Gan, Xinpeng; Lu, Xili; Yang, Li

    2018-01-01

    Abstract Combining self‐healing functions with damage diagnosing, which can achieve timely healing autonomously, is expected to improve the reliability and reduce life cycle cost of materials. Here, a flexible conductive composite composed of a dynamically crosslinked polyurethane bearing Diels–Alder bonds (PUDA) and carbon nanotubes (CNTs), which possess both crack diagnosing and self‐healing functions, is reported. The introduced dynamic Diels–Alder bonds endow the materials self‐healing function and the powder‐based preparation route based on the specially designed CNTs‐coated PUDA micropowders leads to the formation of segregated CNTs network, which makes the composite possess excellent mechanical properties and high conductivity. Because of the sufficient electrothermal and photothermal effect of CNTs, the composites can be healed rapidly and repeatedly by electricity or near‐infrared light based on the retro‐Diels–Alder reaction. An obvious color difference in the infrared thermograph resulting from the resistance difference between damaged and undamaged area can be observed when applying the voltage, which can be used for crack diagnosing. Using the same electrical circuit, the crack in the PUDA/CNTs composite can be noninvasively detected first and then be autonomously healed. The composites also exhibit a strain‐sensing function with good sensitivity and high reliability, thus will have potential applications in electronic strain sensors. PMID:29876226

  17. Communication about patient pain in primary care: development of the Physician-Patient Communication about Pain scale (PCAP).

    PubMed

    Haskard-Zolnierek, Kelly B

    2012-01-01

    This paper describes the development of the 47-item Physician-Patient Communication about Pain (PCAP) scale for use with audiotaped medical visit interactions. Patient pain was assessed with the Medical Outcomes Study SF-36 Bodily Pain Scale. Four raters assessed 181 audiotaped patient interactions with 68 physicians. Descriptive statistics of PCAP items were computed. Principal components analyses with 20 scale items were used to reduce the scale to composite variables for analyses. Validity was assessed through (1) comparing PCAP composite scores for patients with high versus low pain and (2) correlating PCAP composites with a separate communication rating scale. Principal components analyses yielded four physician and five patient communication composites (mean alpha=.77). Some evidence for concurrent validity was provided (5 of 18 correlations with communication validation rating scale were significant). Paired-sample t tests showed significant differences for 4 patient PCAP composites, showing the PCAP scale discriminates between high and low pain patients' communication. The PCAP scale shows partial evidence of reliability and two forms of validity. More research with this scale (developing more reliable and valid composites) is needed to extend these preliminary findings before this scale is applicable for use in practice. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  18. Design and rationale of the MICHELANGELO Organization to Assess Strategies in Acute Ischemic Syndromes (OASIS)-5 trial program evaluating fondaparinux, a synthetic factor Xa inhibitor, in patients with non-ST-segment elevation acute coronary syndromes.

    PubMed

    Mehta, Shamir R; Yusuf, Salim; Granger, Christopher B; Wallentin, Lars; Peters, Ron J G; Bassand, Jean-Pierre; Budaj, Andrzej; Joyner, Campbell; Chrolavicius, Susan; Fox, Keith A A

    2005-12-01

    Factor Xa plays a central role in the generation of thrombin, making it a novel target for treatment of arterial thrombosis. Fondaparinux, a synthetic pentasaccharide, is a factor Xa inhibitor, which has been shown to be superior to enoxaparin for the prevention of venous thrombosis. We designed a large, phase III, randomized trial to evaluate the efficacy and safety of fondaparinux compared with enoxaparin in acute coronary syndromes. The OASIS-5 trial is a randomized, double-blind trial of fondaparinux versus enoxaparin in 20,000 patients with unstable angina or non-ST-segment elevation myocardial infarction. The primary objective is to determine whether fondaparinux is noninferior to enoxaparin in preventing the composite of death, new myocardial infarction, and refractory ischemia at 9 days (primary outcome) and at 30 days (secondary outcome) after randomization. There will be additional follow-up of all patients for 3 to 6 months after randomization. If noninferiority is established at 9 days, superiority will be tested. The primary safety outcome is to evaluate the rates of major bleeds in the 2 groups with the balance of benefit and risk assessed by comparing the impact on the composite of the primary and safety outcomes. Secondary outcomes are each component of the composite primary outcome separately at days 9, 30, and up to 6 months. The TIMACS, a major substudy using a partial 2x2 factorial design evaluating whether early angiography and intervention (within 24 hours) are superior to a more delayed approach (after 36 hours) in reducing major ischemic events at 6 months after randomization. The MICHELANGELO OASIS 5 program will provide a comprehensive and reliable evaluation of fondaparinux in a broad spectrum of patients with ACS.

  19. Composite structural materials. [fiber reinforced composites for aircraft structures

    NASA Technical Reports Server (NTRS)

    Ansell, G. S.; Loewy, R. G.; Wiberly, S. E.

    1981-01-01

    Physical properties of fiber reinforced composites; structural concepts and analysis; manufacturing; reliability; and life prediction are subjects of research conducted to determine the long term integrity of composite aircraft structures under conditions pertinent to service use. Progress is reported in (1) characterizing homogeneity in composite materials; (2) developing methods for analyzing composite materials; (3) studying fatigue in composite materials; (4) determining the temperature and moisture effects on the mechanical properties of laminates; (5) numerically analyzing moisture effects; (6) numerically analyzing the micromechanics of composite fracture; (7) constructing the 727 elevator attachment rib; (8) developing the L-1011 engine drag strut (CAPCOMP 2 program); (9) analyzing mechanical joints in composites; (10) developing computer software; and (11) processing science and technology, with emphasis on the sailplane project.

  20. A study on the real-time reliability of on-board equipment of train control system

    NASA Astrophysics Data System (ADS)

    Zhang, Yong; Li, Shiwei

    2018-05-01

    Real-time reliability evaluation is conducive to establishing a condition based maintenance system for the purpose of guaranteeing continuous train operation. According to the inherent characteristics of the on-board equipment, the connotation of reliability evaluation of on-board equipment is defined and the evaluation index of real-time reliability is provided in this paper. From the perspective of methodology and practical application, the real-time reliability of the on-board equipment is discussed in detail, and the method of evaluating the realtime reliability of on-board equipment at component level based on Hidden Markov Model (HMM) is proposed. In this method the performance degradation data is used directly to realize the accurate perception of the hidden state transition process of on-board equipment, which can achieve a better description of the real-time reliability of the equipment.

  1. Reliability analysis of the Chinese version of the Functional Assessment of Cancer Therapy - Leukemia (FACT-Leu) scale based on multivariate generalizability theory.

    PubMed

    Meng, Qiong; Yang, Zheng; Wu, Yang; Xiao, Yuanyuan; Gu, Xuezhong; Zhang, Meixia; Wan, Chonghua; Li, Xiaosong

    2017-05-04

    The Functional Assessment of Cancer Therapy-Leukemia (FACT-Leu) scale, a leukemia-specific instrument for determining the health-related quality of life (HRQOL) in patients with leukemia, had been developed and validated, but there have been no reports on the development of a simplified Chinese version of this scale. This is a new exploration to analyze the reliability of the HRQOL measurement using multivariate generalizability theory (MGT). This study aimed to develop a Chinese version of the FACT-Leu scale and evaluate its reliability using MGT to provide evidence to support the revision and improvement of this scale. The Chinese version of the FACT-Leu scale was developed by four steps: forward translation, backward translation, cultural adaptation and pilot-testing. The HRQOL was measured for eligible inpatients with leukemia using this scale to provide data. A single-facet multivariate Generalizability Study (G-study) design was demonstrated to estimate the variance-covariance components and then several Decision Studies (D-studies) with varying numbers of items were analyzed to obtain reliability coefficients and to understand how much the measurement reliability could be vary as the number of items in MGT changes. One-hundred and one eligible inpatients diagnosed with leukemia were recruited and completed the HRQOL measurement at the time of admission to the hospital. In the G-study, the variation component of the patient-item interaction was largest while the variation component of the item was the smallest for the four of five domains, except for the leukemia-specific (LEUS) domain. In the D-study, at the level of domain, the generalizability coefficients (G) and the indexes of dependability (Ф) for four of the five domains were approximately equal to or greater than 0.80 except for the Emotional Well-being (EWB) domain (>0.70 but <0.80). For the overall scale, the composite G and composite Ф coefficients were greater than 0.90. Based on the G coefficient and Ф coefficient, two decision options for revising this scale considering the number of items were obtained: one is a 37-item version while the other is a 45-item version. The Chinese version of the FACT-Leu scale has good reliability as a whole based on the results of MGT and the implementation of MGT could lead to more informed decisions in complex questionnaire design and improvement.

  2. Interrater and intrarater reliability of FDI criteria applied to photographs of posterior tooth-colored restorations.

    PubMed

    Kim, Dohyun; Ahn, So-Yeon; Kim, Junyoung; Park, Sung-Ho

    2017-07-01

    Since 2007, the FDI World Dental Federation (FDI) criteria have been used for the clinical evaluation of dental restorations. However, the reliability of the FDI criteria has not been sufficiently addressed. The purpose of this study was to assess and compare the interrater and intrarater reliability of the FDI criteria by evaluating posterior tooth-colored restorations photographically. A total of 160 clinical photographs of posterior tooth-colored restorations were evaluated independently by 5 raters with 9 of the FDI criteria suitable for photographic evaluation. The raters recorded the score of each restoration by using 5 grades, and the score was dichotomized into the clinical evaluation scores. After 1 month, 2 of the raters reevaluated the same set of 160 photographs in random order. To estimate the interrater reliability among the 5 raters, the proportion of agreement was calculated, and the Fleiss multirater kappa statistic was used. For the intrarater reliability, the proportion of agreement was calculated, and the Cohen standard kappa statistic was used for each of the 2 raters. The interrater proportion of agreement was 0.41 to 0.57, and the kappa value was 0.09 to 0.39. Overall, the intrarater reliability was higher than the interrater reliability, and rater 1 demonstrated higher intrarater reliability than rater 2. The proportion of agreement and kappa values increased when the 5 scores were dichotomized. The reliability was relatively lower for the esthetic properties compared with the functional or biological properties. Within the limitations of this study, the FDI criteria presented slight to fair interrater reliability and fair to excellent intrarater reliability in the photographic evaluation of posterior tooth-colored restorations. The reliability was improved by simplifying the evaluation scores. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Long-term prediction of fish growth under varying ambient temperature using a multiscale dynamic model

    PubMed Central

    2009-01-01

    Background Feed composition has a large impact on the growth of animals, particularly marine fish. We have developed a quantitative dynamic model that can predict the growth and body composition of marine fish for a given feed composition over a timespan of several months. The model takes into consideration the effects of environmental factors, particularly temperature, on growth, and it incorporates detailed kinetics describing the main metabolic processes (protein, lipid, and central metabolism) known to play major roles in growth and body composition. Results For validation, we compared our model's predictions with the results of several experimental studies. We showed that the model gives reliable predictions of growth, nutrient utilization (including amino acid retention), and body composition over a timespan of several months, longer than most of the previously developed predictive models. Conclusion We demonstrate that, despite the difficulties involved, multiscale models in biology can yield reasonable and useful results. The model predictions are reliable over several timescales and in the presence of strong temperature fluctuations, which are crucial factors for modeling marine organism growth. The model provides important improvements over existing models. PMID:19903354

  4. Raising the Reliability of Forming Rolls by Alloying Their Core with Copper

    NASA Astrophysics Data System (ADS)

    Zhizhkina, N. A.

    2016-11-01

    The mechanical properties and the structure of forming rolls from cast irons of different compositions are studied. A novel iron including a copper additive that lowers its chilling and raises the homogeneity of the structure is suggested for the roll cores. The use of such iron should raise the reliability of the rolls in operation.

  5. Synthesis, Characterization And Modeling Of Functionally Graded Multifunctional Hybrid Composites For Extreme Environments

    DTIC Science & Technology

    2017-04-04

    research thrust areas are designed to enable the development of reliable, damage tolerant, lightweight structures with excellent thermal management...46 2. RESEARCH THRUST AREA: MULTISCALE CHARACTERIZATION AND MODELING .................................... 56 2.1 DESIGN OF MATERIALS...The research thrust areas are designed to enable the development of reliable, damage tolerant, lightweight structures with excellent thermal

  6. Are Validity and Reliability "Relevant" in Qualitative Evaluation Research?

    ERIC Educational Resources Information Center

    Goodwin, Laura D.; Goodwin, William L.

    1984-01-01

    The views of prominant qualitative methodologists on the appropriateness of validity and reliability estimation for the measurement strategies employed in qualitative evaluations are summarized. A case is made for the relevance of validity and reliability estimation. Definitions of validity and reliability for qualitative measurement are presented…

  7. Assessing the reliability of FTIR spectroscopy measurements and validity of bioelectrical impedance analysis as a surrogate measure of body composition among children and adolescents aged 8-19 years attending schools in Kampala, Uganda.

    PubMed

    Ndagire, Catherine T; Muyonga, John H; Isabirye, Dan; Odur, Benard; Somda, Serge M A; Bukenya, Richard; Andrade, Juan E; Nakimbugwe, Dorothy

    2018-06-04

    Accurate measurement of body composition in children and adolescents is important as the quantities of fat and fat-free mass have implications for health risk. The objectives of the present study were: to determine the reliability of Fourier Transform Infrared spectroscopy (FTIR) measurements and; compare the Fat Mass (FM), Fat Free Mass (FFM) and body fat percentage (%BF) values determined by bioelectrical impedance analysis (BIA) to those determined by deuterium dilution method (DDM) to identify correlations and agreement between the two methods. A cross-sectional study was conducted among 203 children and adolescents aged 8-19 years attending schools in Kampala city, Uganda. Pearson product-moment correlation at 5% significance level was considered for assessing correlations. Bland Altman analysis was used to examine the agreement between of FTIR measurements and between estimates by DDM and BIA.. Reliability of measurements was determined by Cronbach's alpha. There was good agreement between the in vivo D 2 O saliva enrichment measurements at 3 and 4 h among the studied age groups based on Bland-Altman plots. Cronbach's alpha revealed that measurements of D 2 O saliva enrichment had very good reliability. For children and young adolescents, DDM and BIA gave similar estimates of FFM, FM, and %BF. Among older adolescents, BIA significantly over-estimated FFM and significantly under-estimated FM and %BF compared to estimates by DDM. The correlation between FFM, FM and %BF estimates by DDM and BIA was high and significant among young and older adolescents and for FFM among children. Reliability of the FTIR spectroscopy measurements was very good among the studied population. BIA is suitable for assessing body composition among children (8-9 years) and young adolescents (10-14 years) but not among older adolescents (15-19 years) in Uganda. The body composition measurements of older adolescents determined by DDM can be predicted using those provided by BIA using population-specific regression equations.

  8. Escherichia coli sampling reliability at a frequently closed Chicago beach: monitoring and management implications

    USGS Publications Warehouse

    Whitman, Richard L.; Nevers, Meredith B.

    2004-01-01

    Monitoring beaches for recreational water quality is becoming more common, but few sampling designs or policy approaches have evaluated the efficacy of monitoring programs. The authors intensively sampled water for E. coli (N=1770) at 63rd Street Beach, Chicago for 6 months in 2000 in order to (1) characterize spatial-temporal trends, (2) determine between and within transect variation, and (3) estimate sample size requirements and determine sampling reliability.E. coli counts were highly variable within and between sampling sites but spatially and diurnally autocorrelated. Variation in counts decreased with water depth and time of day. Required number of samples was high for 70% precision around the critical closure level (i.e., 6 within or 24 between transect replicates). Since spatial replication may be cost prohibitive, composite sampling is an alternative once sources of error have been well defined. The results suggest that beach monitoring programs may be requiring too few samples to fulfill management objectives desired. As the recreational water quality national database is developed, it is important that sampling strategies are empirically derived from a thorough understanding of the sources of variation and the reliability of collected data. Greater monitoring efficacy will yield better policy decisions, risk assessments, programmatic goals, and future usefulness of the information.

  9. European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 30: factorial models to Brazilian cancer patients

    PubMed Central

    Campos, Juliana Alvares Duarte Bonini; Spexoto, Maria Cláudia Bernardes; da Silva, Wanderson Roberto; Serrano, Sergio Vicente; Marôco, João

    2018-01-01

    ABSTRACT Objective To evaluate the psychometric properties of the seven theoretical models proposed in the literature for European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 30 (EORTC QLQ-C30), when applied to a sample of Brazilian cancer patients. Methods Content and construct validity (factorial, convergent, discriminant) were estimated. Confirmatory factor analysis was performed. Convergent validity was analyzed using the average variance extracted. Discriminant validity was analyzed using correlational analysis. Internal consistency and composite reliability were used to assess the reliability of instrument. Results A total of 1,020 cancer patients participated. The mean age was 53.3±13.0 years, and 62% were female. All models showed adequate factorial validity for the study sample. Convergent and discriminant validities and the reliability were compromised in all of the models for all of the single items referring to symptoms, as well as for the “physical function” and “cognitive function” factors. Conclusion All theoretical models assessed in this study presented adequate factorial validity when applied to Brazilian cancer patients. The choice of the best model for use in research and/or clinical protocols should be centered on the purpose and underlying theory of each model. PMID:29694609

  10. Developing a Workflow Composite Score to Measure Clinical Information Logistics. A Top-down Approach.

    PubMed

    Liebe, J D; Hübner, U; Straede, M C; Thye, J

    2015-01-01

    Availability and usage of individual IT applications have been studied intensively in the past years. Recently, IT support of clinical processes is attaining increasing attention. The underlying construct that describes the IT support of clinical workflows is clinical information logistics. This construct needs to be better understood, operationalised and measured. It is therefore the aim of this study to propose and develop a workflow composite score (WCS) for measuring clinical information logistics and to examine its quality based on reliability and validity analyses. We largely followed the procedural model of MacKenzie and colleagues (2011) for defining and conceptualising the construct domain, for developing the measurement instrument, assessing the content validity, pretesting the instrument, specifying the model, capturing the data and computing the WCS and testing the reliability and validity. Clinical information logistics was decomposed into the descriptors data and information, function, integration and distribution, which embraced the framework validated by an analysis of the international literature. This framework was refined selecting representative clinical processes. We chose ward rounds, pre- and post-surgery processes and discharge as sample processes that served as concrete instances for the measurements. They are sufficiently complex, represent core clinical processes and involve different professions, departments and settings. The score was computed on the basis of data from 183 hospitals of different size, ownership, location and teaching status. Testing the reliability and validity yielded encouraging results: the reliability was high with r(split-half) = 0.89, the WCS discriminated between groups; the WCS correlated significantly and moderately with two EHR models and the WCS received good evaluation results by a sample of chief information officers (n = 67). These findings suggest the further utilisation of the WCS. As the WCS does not assume ideal workflows as a gold standard but measures IT support of clinical workflows according to validated descriptors a high portability of the WCS to other hospitals in other countries is very likely. The WCS will contribute to a better understanding of the construct clinical information logistics.

  11. Composite membranes and methods for making same

    DOEpatents

    Routkevitch, Dmitri; Polyakov, Oleg G

    2012-07-03

    Composite membranes that are adapted for separation, purification, filtration, analysis, reaction and sensing. The composite membranes can include a porous support structure having elongate pore channels extending through the support structure. The composite membrane also includes an active layer comprising an active layer material, where the active layer material is completely disposed within the pore channels between the surfaces of the support structure. The active layer is intimately integrated within the support structure, thus enabling great robustness, reliability, resistance to mechanical stress and thermal cycling, and high selectivity. Methods for the fabrication of composite membranes are also provided.

  12. Probabilistic assessment of uncertain adaptive hybrid composites

    NASA Technical Reports Server (NTRS)

    Shiao, Michael C.; Singhal, Surendra N.; Chamis, Christos C.

    1994-01-01

    Adaptive composite structures using actuation materials, such as piezoelectric fibers, were assessed probabilistically utilizing intraply hybrid composite mechanics in conjunction with probabilistic composite structural analysis. Uncertainties associated with the actuation material as well as the uncertainties in the regular (traditional) composite material properties were quantified and considered in the assessment. Static and buckling analyses were performed for rectangular panels with various boundary conditions and different control arrangements. The probability density functions of the structural behavior, such as maximum displacement and critical buckling load, were computationally simulated. The results of the assessment indicate that improved design and reliability can be achieved with actuation material.

  13. Composite turbine blade design options for Claude (open) cycle OTEC power systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Penney, T R

    1985-11-01

    Small-scale turbine rotors made from composites offer several technical advantages for a Claude (open) cycle ocean thermal energy conversion (OTEC) power system. Westinghouse Electric Corporation has designed a composite turbine rotor/disk using state-of-the-art analysis methods for large-scale (100-MW/sub e/) open cycle OTEC applications. Near-term demonstrations using conventional low-pressure turbine blade shapes with composite material would achieve feasibility and modern credibility of the open cycle OTEC power system. Application of composite blades for low-pressure turbo-machinery potentially improves the reliability of conventional metal blades affected by stress corrosion.

  14. Processing and Properties Of Refractory Zirconium Diboride Composites For Use In High Temperature Applications

    NASA Technical Reports Server (NTRS)

    Stackpoole, Margaret; Gusman, M.; Ellerby, D.; Johnson, S. M.; Arnold, Jim (Technical Monitor)

    2001-01-01

    The Thermal Protection Materials and Systems Branch at NASA Ames Research Center is involved in the development of a class of refractory oxidation-resistant diboride composites termed Ultra High Temperature Ceramics or UHTCs. These composites have good high temperature properties making them candidate materials for thermal protection system (TPS) applications. The current research focuses on improving processing methods to develop more reliable composites with enhanced thermal and mechanical properties. This presentation will concentrate on the processing of ZrB2/SiC composites. Some preliminary mechanical properties and oxidation data will also be presented.

  15. Evaluation of reliability modeling tools for advanced fault tolerant systems

    NASA Technical Reports Server (NTRS)

    Baker, Robert; Scheper, Charlotte

    1986-01-01

    The Computer Aided Reliability Estimation (CARE III) and Automated Reliability Interactice Estimation System (ARIES 82) reliability tools for application to advanced fault tolerance aerospace systems were evaluated. To determine reliability modeling requirements, the evaluation focused on the Draper Laboratories' Advanced Information Processing System (AIPS) architecture as an example architecture for fault tolerance aerospace systems. Advantages and limitations were identified for each reliability evaluation tool. The CARE III program was designed primarily for analyzing ultrareliable flight control systems. The ARIES 82 program's primary use was to support university research and teaching. Both CARE III and ARIES 82 were not suited for determining the reliability of complex nodal networks of the type used to interconnect processing sites in the AIPS architecture. It was concluded that ARIES was not suitable for modeling advanced fault tolerant systems. It was further concluded that subject to some limitations (the difficulty in modeling systems with unpowered spare modules, systems where equipment maintenance must be considered, systems where failure depends on the sequence in which faults occurred, and systems where multiple faults greater than a double near coincident faults must be considered), CARE III is best suited for evaluating the reliability of advanced tolerant systems for air transport.

  16. Blinded evaluation of interrater reliability of an operative competency assessment tool for direct laryngoscopy and rigid bronchoscopy.

    PubMed

    Ishman, Stacey L; Benke, James R; Johnson, Kaalan Erik; Zur, Karen B; Jacobs, Ian N; Thorne, Marc C; Brown, David J; Lin, Sandra Y; Bhatti, Nasir; Deutsch, Ellen S

    2012-10-01

    OBJECTIVES To confirm interrater reliability using blinded evaluation of a skills-assessment instrument to assess the surgical performance of resident and fellow trainees performing pediatric direct laryngoscopy and rigid bronchoscopy in simulated models. DESIGN Prospective, paired, blinded observational validation study. SUBJECTS Paired observers from multiple institutions simultaneously evaluated residents and fellows who were performing surgery in an animal laboratory or using high-fidelity manikins. The evaluators had no previous affiliation with the residents and fellows and did not know their year of training. INTERVENTIONS One- and 2-page versions of an objective structured assessment of technical skills (OSATS) assessment instrument composed of global and a task-specific surgical items were used to evaluate surgical performance. RESULTS Fifty-two evaluations were completed by 17 attending evaluators. The instrument agreement for the 2-page assessment was 71.4% when measured as a binary variable (ie, competent vs not competent) (κ = 0.38; P = .08). Evaluation as a continuous variable revealed a 42.9% percentage agreement (κ = 0.18; P = .14). The intraclass correlation was 0.53, considered substantial/good interrater reliability (69% reliable). For the 1-page instrument, agreement was 77.4% when measured as a binary variable (κ = 0.53, P = .0015). Agreement when evaluated as a continuous measure was 71.0% (κ = 0.54, P < .001). The intraclass correlation was 0.73, considered high interrater reliability (85% reliable). CONCLUSIONS The OSATS assessment instrument is an effective tool for evaluating surgical performance among trainees with acceptable interrater reliability in a simulator setting. Reliability was good for both the 1- and 2-page OSATS checklists, and both serve as excellent tools to provide immediate formative feedback on operational competency.

  17. A New Tool for Nutrition App Quality Evaluation (AQEL): Development, Validation, and Reliability Testing.

    PubMed

    DiFilippo, Kristen Nicole; Huang, Wenhao; Chapman-Novakofski, Karen M

    2017-10-27

    The extensive availability and increasing use of mobile apps for nutrition-based health interventions makes evaluation of the quality of these apps crucial for integration of apps into nutritional counseling. The goal of this research was the development, validation, and reliability testing of the app quality evaluation (AQEL) tool, an instrument for evaluating apps' educational quality and technical functionality. Items for evaluating app quality were adapted from website evaluations, with additional items added to evaluate the specific characteristics of apps, resulting in 79 initial items. Expert panels of nutrition and technology professionals and app users reviewed items for face and content validation. After recommended revisions, nutrition experts completed a second AQEL review to ensure clarity. On the basis of 150 sets of responses using the revised AQEL, principal component analysis was completed, reducing AQEL into 5 factors that underwent reliability testing, including internal consistency, split-half reliability, test-retest reliability, and interrater reliability (IRR). Two additional modifiable constructs for evaluating apps based on the age and needs of the target audience as selected by the evaluator were also tested for construct reliability. IRR testing using intraclass correlations (ICC) with all 7 constructs was conducted, with 15 dietitians evaluating one app. Development and validation resulted in the 51-item AQEL. These were reduced to 25 items in 5 factors after principal component analysis, plus 9 modifiable items in two constructs that were not included in principal component analysis. Internal consistency and split-half reliability of the following constructs derived from principal components analysis was good (Cronbach alpha >.80, Spearman-Brown coefficient >.80): behavior change potential, support of knowledge acquisition, app function, and skill development. App purpose split half-reliability was .65. Test-retest reliability showed no significant change over time (P>.05) for all but skill development (P=.001). Construct reliability was good for items assessing age appropriateness of apps for children, teens, and a general audience. In addition, construct reliability was acceptable for assessing app appropriateness for various target audiences (Cronbach alpha >.70). For the 5 main factors, ICC (1,k) was >.80, with a P value of <.05. When 15 nutrition professionals evaluated one app, ICC (2,15) was .98, with a P value of <.001 for all 7 constructs when the modifiable items were specified for adults seeking weight loss support. Our preliminary effort shows that AQEL is a valid, reliable instrument for evaluating nutrition apps' qualities for clinical interventions by nutrition clinicians, educators, and researchers. Further efforts in validating AQEL in various contexts are needed. ©Kristen Nicole DiFilippo, Wenhao Huang, Karen M. Chapman-Novakofski. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 27.10.2017.

  18. An evaluation of the Iosipescu specimen for composite materials shear property measurement

    NASA Technical Reports Server (NTRS)

    Morton, J.; Ho, H.; Tsai, M. Y.; Farley, G. L.

    1992-01-01

    A detailed evaluation of the suitability of the Iosipescu specimen tested in the modified Wyoming fixture is presented. A linear finite element model of the specimen is used to assess the uniformity of the shear stress field in the vicinity of the notch, and demonstrate the effect of the nonuniform stress field upon strain gage measurements used for the determination of composite shear moduli. Based upon test results from graphite-epoxy laminates, the proximity of the load introduction point to the test section and the material orthotropy greatly influence the individual gage readings, however, shear modulus determination is not significantly affected by the lack of pure shear. Correction factors are needed to allow for the nonuniformity of the strain field and the use of the average shear stress in the shear modulus evaluation. The correction factors are determined for the region occupied by the strain gage rosette. A comparison of the strain gage readings from one surface of a specimen with corresponding data from moire interferometry on the opposite face documented an extreme sensitivity of some fiber orientations to eccentric loading which induced twisting and spurious shear stress-strain curves. The discovery of specimen twisting explains the apparently inconsistent shear property data found in the literature. Recommendations for improving the reliability and accuracy of the shear modulus values are made, and the implications for shear strength measurement discussed.

  19. SPSS Macros for Assessing the Reliability and Agreement of Student Evaluations of Teaching

    ERIC Educational Resources Information Center

    Morley, Donald D.

    2009-01-01

    This article reports and demonstrates two SPSS macros for calculating Krippendorff's alpha and intraclass reliability coefficients in repetitive situations where numerous coefficients are needed. Specifically, the reported SPSS macros were used to evaluate the interrater agreement and reliability of student evaluations of teaching in thousands of…

  20. Evaluation methodologies for an advanced information processing system

    NASA Technical Reports Server (NTRS)

    Schabowsky, R. S., Jr.; Gai, E.; Walker, B. K.; Lala, J. H.; Motyka, P.

    1984-01-01

    The system concept and requirements for an Advanced Information Processing System (AIPS) are briefly described, but the emphasis of this paper is on the evaluation methodologies being developed and utilized in the AIPS program. The evaluation tasks include hardware reliability, maintainability and availability, software reliability, performance, and performability. Hardware RMA and software reliability are addressed with Markov modeling techniques. The performance analysis for AIPS is based on queueing theory. Performability is a measure of merit which combines system reliability and performance measures. The probability laws of the performance measures are obtained from the Markov reliability models. Scalar functions of this law such as the mean and variance provide measures of merit in the AIPS performability evaluations.

  1. Quantitative Assessment of Antimicrobial Activity of PLGA Films Loaded with 4-Hexylresorcinol

    PubMed Central

    Kemme, Michael; Heinzel-Wieland, Regina

    2018-01-01

    Profound screening and evaluation methods for biocide-releasing polymer films are crucial for predicting applicability and therapeutic outcome of these drug delivery systems. For this purpose, we developed an agar overlay assay embedding biopolymer composite films in a seeded microbial lawn. By combining this approach with model-dependent analysis for agar diffusion, antimicrobial potency of the entrapped drug can be calculated in terms of minimum inhibitory concentrations (MICs). Thus, the topical antiseptic 4-hexylresorcinol (4-HR) was incorporated into poly(lactic-co-glycolic acid) (PLGA) films at different loadings up to 3.7 mg/cm2 surface area through a solvent casting technique. The antimicrobial activity of 4-HR released from these composite films was assessed against a panel of Gram-negative and Gram–positive bacteria, yeasts and filamentous fungi by the proposed assay. All the microbial strains tested were susceptible to PLGA-4-HR films with MIC values down to 0.4% (w/w). The presented approach serves as a reliable method in screening and quantifying the antimicrobial activity of polymer composite films. Moreover, 4-HR-loaded PLGA films are a promising biomaterial that may find future application in the biomedical and packaging sector. PMID:29324696

  2. On the Problems of Cracking and the Question of Structural Integrity of Engineering Composite Materials

    NASA Astrophysics Data System (ADS)

    Beaumont, Peter W. R.

    2014-02-01

    Predicting precisely where a crack will develop in a material under stress and exactly when in time catastrophic fracture of the component will occur is one the oldest unsolved mysteries in the design and building of large engineering structures. Where human life depends upon engineering ingenuity, the burden of testing to prove a "fracture safe design" is immense. For example, when human life depends upon structural integrity as an essential design requirement, it takes ten thousand material test coupons per composite laminate configuration to evaluate an airframe plus loading to ultimate failure tails, wing boxes, and fuselages to achieve a commercial aircraft airworthiness certification. Fitness considerations for long-life implementation of aerospace composites include understanding phenomena such as impact, fatigue, creep, and stress corrosion cracking that affect reliability, life expectancy, and durability of structure. Structural integrity analysis treats the design, the materials used, and figures out how best components and parts can be joined. Furthermore, SI takes into account service duty. However, there are conflicting aims in the complete design process of designing simultaneously for high efficiency and safety assurance throughout an economically viable lifetime with an acceptable level of risk.

  3. Covariate-free and Covariate-dependent Reliability.

    PubMed

    Bentler, Peter M

    2016-12-01

    Classical test theory reliability coefficients are said to be population specific. Reliability generalization, a meta-analysis method, is the main procedure for evaluating the stability of reliability coefficients across populations. A new approach is developed to evaluate the degree of invariance of reliability coefficients to population characteristics. Factor or common variance of a reliability measure is partitioned into parts that are, and are not, influenced by control variables, resulting in a partition of reliability into a covariate-dependent and a covariate-free part. The approach can be implemented in a single sample and can be applied to a variety of reliability coefficients.

  4. Static and Fatigue Strength Evaluations for Bolted Composite/Steel Joints for Heavy Vehicle Chassis Components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Xin; Stephens, Elizabeth V.; Herling, Darrell R.

    2004-09-14

    In May 2003, ORNL and PNNL began collaboration on a four year research effort focused on developing joining techniques to overcome the technical issues associated with joining lightweight materials in heavy vehicles. The initial focus of research is the development and validation of joint designs for a composite structural member attached to a metal member that satisfy the structural requirements both economically and reliably. Huck-bolting is a common joining method currently used in heavy truck chassis structures. The initial round of testing was conducted to establish a performance benchmark by evaluating the static and fatigue behavior of an existing steel/steelmore » chassis joint at the single huck-bolt level. Both tension and shear loading conditions were considered, and the resulting static and fatigue strengths will be used to guide the joint design for a replacement composite/steel joint. A commercially available, pultruded composite material was chosen to study the generic issues related to composite/steel joints. Extren is produced by STRONGWELL, and it is a combination of fiberglass reinforcement and thermosetting polyester or vinyl ester resin systems. Extren sheets of 3.2 mm thick were joined to 1.4 mm SAE1008 steel sheets with a standard grade 5 bolt with 6.35 mm diameter. Both tension and shear loading modes were considered for the single hybrid joint under static and fatigue loading conditions. Since fiberglass reinforced thermoset polymer composites are a non-homogenous material, their strengths and behavior are dependent upon the design of the composite and reinforcement. The Extren sheet stock was cut along the longitudinal direction to achieve maximum net-section strength. The effects of various manufacturing factors and operational conditions on the static and fatigue strength of the hybrid joint were modeled and experimentally verified. It was found that loading mode and washer size have significant influence on the static and fatigue strength of the hybrid joint. The effect of different fatigue test frequencies on the sample temperature and the resulting fatigue life was also examined.« less

  5. The reliability of multidimensional neuropsychological measures: from alpha to omega.

    PubMed

    Watkins, Marley W

    To demonstrate that Coefficient omega, a model-based estimate, is more a more appropriate index of reliability than coefficient alpha for the multidimensional scales that are commonly employed by neuropsychologists. As an illustration, a structural model of an overarching general factor and four first-order factors for the WAIS-IV based on the standardization sample of 2200 participants was identified and omega coefficients were subsequently computed for WAIS-IV composite scores. Alpha coefficients were ≥ .90 and omega coefficients ranged from .75 to .88 for WAIS-IV factor index scores, indicating that the blend of general and group factor variance in each index score created a reliable multidimensional composite. However, the amalgam of variance from general and group factors did not allow the precision of Full Scale IQ (FSIQ) and factor index scores to be disentangled. In contrast, omega hierarchical coefficients were low for all four factor index scores (.10-.41), indicating that most of the reliable variance of each factor index score was due to the general intelligence factor. In contrast, the omega hierarchical coefficient for the FSIQ score was .84. Meaningful interpretation of WAIS-IV factor index scores as unambiguous indicators of group factors is imprecise, thereby fostering unreliable identification of neurocognitive strengths and weaknesses, whereas the WAIS-IV FSIQ score can be interpreted as a reliable measure of general intelligence. It was concluded that neuropsychologists should base their clinical decisions on reliable scores as indexed by coefficient omega.

  6. Reliability and Validity towards Environment Attitude Scale for Secondary School Students

    ERIC Educational Resources Information Center

    Uzunoz, Abdulkadir

    2011-01-01

    This research, tries to develop an attitude scale (educational access schemes (EAS) for SS) which determines the approaches of secondary students for environment. First 400 secondary students were invited to write a composition named "The importance of environment and its position in our lives". The compositions were examined one by one…

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rohwer, Lauren E. S.; Martin, James E.

    In this study, reliable methods for tin whisker mitigation are needed for applications that utilize tin-plated commercial components. Tin can grow whiskers that can lead to electrical shorting, possibly causing critical systems to fail catastrophically. The mechanisms of tin whisker growth are unclear and this makes prediction of the lifetimes of critical components uncertain. The development of robust methods for tin whisker mitigation is currently the best approach to eliminating the risk of shorting. Current mitigation methods are based on unfilled polymer coatings that are not impenetrable to tin whiskers. In this paper we report tin whisker mitigation results formore » several filled polymer coatings. The whisker-penetration resistance of the coatings was evaluated at elevated temperature and high humidity and under temperature cycling conditions. The composite coatings comprised Ni and MgF 2-coated Al/Ni/Al platelets in epoxy resin or silicone rubber. In addition to improved whisker mitigation, these platelet composites have enhanced thermal conductivity and dielectric constant compared with unfilled polymers.« less

  8. Correlation of ash-flow tuffs.

    USGS Publications Warehouse

    Hildreth, W.; Mahood, G.

    1985-01-01

    Discrimination and correlation of ash-flow sheets is important in structurally complex, long-lived volcanic fields where such sheets provide the best keys to the regional stratigraphic framework. Three-dimensional complexities resulting from pulsatory eruptions, sectorial emplacement, mechanical sorting during outflow, thermal and compositional zoning of magmas, the physical zoning of cooling units, and structural and erosional disruption can make such correlation and discrimination difficult. When lithologic, magnetic, petrographic, chemical, and isotopic criteria for correlating ash-flow sheets are critically evaluated, many problems and pitfalls can be identified. Distinctive phenocrysts, pumice clasts, and lithic fragments are among the more reliable criteria, as are high-precision K-Ar ages and thermal remanent magnetization (TRM) directions in unaltered welded tuff. Chemical correlation methods should rely principally upon welded or nonwelded pumice blocks, not upon the ash-flow matrix, which is subject to fractionation, mixing, and contamination during emplacement. Compositional zoning of most large sheets requires that many samples be analyzed before phenocryst, glass or whole-rock chemical trends can be used confidently as correlation criteria.-Authors

  9. Chemical Differentiation of Osseous, Dental, and Non-skeletal Materials in Forensic Anthropology using Elemental Analysis.

    PubMed

    Zimmerman, Heather A; Meizel-Lambert, Cayli J; Schultz, John J; Sigman, Michael E

    2015-03-01

    Forensic anthropologists are generally able to identify skeletal materials (bone and tooth) using gross anatomical features; however, highly fragmented or taphonomically altered materials may be problematic to identify. Several chemical analysis techniques have been shown to be reliable laboratory methods that can be used to determine if questionable fragments are osseous, dental, or non-skeletal in nature. The purpose of this review is to provide a detailed background of chemical analysis techniques focusing on elemental compositions that have been assessed for use in differentiating osseous, dental, and non-skeletal materials. More recently, chemical analysis studies have also focused on using the elemental composition of osseous/dental materials to evaluate species and provide individual discrimination, but have generally been successful only in small, closed groups, limiting their use forensically. Despite significant advances incorporating a variety of instruments, including handheld devices, further research is necessary to address issues in standardization, error rates, and sample size/diversity. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  10. Profiling defect depth in composite materials using thermal imaging NDE

    NASA Astrophysics Data System (ADS)

    Obeidat, Omar; Yu, Qiuye; Han, Xiaoyan

    2018-04-01

    Sonic Infrared (IR) NDE, is a relatively new NDE technology; it has been demonstrated as a reliable and sensitive method to detect defects. SIR uses ultrasonic excitation with IR imaging to detect defects and flaws in the structures being inspected. An IR camera captures infrared radiation from the target for a period of time covering the ultrasound pulse. This period of time may be much longer than the pulse depending on the defect depth and the thermal properties of the materials. With the increasing deployment of composites in modern aerospace and automobile structures, fast, wide-area and reliable NDE methods are necessary. Impact damage is one of the major concerns in modern composites. Damage can occur at a certain depth without any visual indication on the surface. Defect depth information can influence maintenance decisions. Depth profiling relies on the time delays in the captured image sequence. We'll present our work on the defect depth profiling by using the temporal information of IR images. An analytical model is introduced to describe heat diffusion from subsurface defects in composite materials. Depth profiling using peak time is introduced as well.

  11. Reliability model for ductile hybrid FRP rebar using randomly dispersed chopped fibers

    NASA Astrophysics Data System (ADS)

    Behnam, Bashar Ramzi

    Fiber reinforced polymer composites or simply FRP composites have become more attractive to civil engineers in the last two decades due to their unique mechanical properties. However, there are many obstacles such as low elasticity modulus, non-ductile behavior, high cost of the fibers, high manufacturing costs, and absence of rigorous characterization of the uncertainties of the mechanical properties that restrict the use of these composites. However, when FRP composites are used to develop reinforcing rebars in concrete structural members to replace the conventional steel, a huge benefit can be achieved since FRP materials don't corrode. Two FRP rebar models are proposed that make use of multiple types of fibers to achieve ductility, and chopped fibers are used to reduce the manufacturing costs. In order to reach the most optimum fractional volume of each type of fiber, to minimize the cost of the proposed rebars, and to achieve a safe design by considering uncertainties in the materials and geometry of sections, appropriate material resistance factors have been developed, and a Reliability Based Design Optimization (RBDO), has been conducted for the proposed schemes.

  12. Development and Psychometric Testing of a Sexual Concerns Questionnaire for Kidney Transplant Recipients.

    PubMed

    Muehrer, Rebecca J; Lanuza, Dorothy M; Brown, Roger L; Djamali, Arjang

    2015-01-01

    This study describes the development and psychometric testing of the Sexual Concerns Questionnaire (SCQ) in kidney transplant (KTx) recipients. Construct validity was assessed using the Kroonenberg and Lewis exploratory/confirmatory procedure and testing hypothesized relationships with established questionnaires. Configural and weak invariance were examined across gender, dialysis history, relationship status, and transplant type. Reliability was assessed with Cronbach's alpha, composite reliability, and test-retest reliability. Factor analysis resulted in a 7-factor solution and suggests good model fit. Construct validity was also supported by the tests of hypothesized relationships. Configural and weak invariance were supported for all subgroups. Reliability of the SCQ was also supported. Findings indicate the SCQ is a valid and reliable measure of KTx recipients' sexual concerns.

  13. A Review on VSC-HVDC Reliability Modeling and Evaluation Techniques

    NASA Astrophysics Data System (ADS)

    Shen, L.; Tang, Q.; Li, T.; Wang, Y.; Song, F.

    2017-05-01

    With the fast development of power electronics, voltage-source converter (VSC) HVDC technology presents cost-effective ways for bulk power transmission. An increasing number of VSC-HVDC projects has been installed worldwide. Their reliability affects the profitability of the system and therefore has a major impact on the potential investors. In this paper, an overview of the recent advances in the area of reliability evaluation for VSC-HVDC systems is provided. Taken into account the latest multi-level converter topology, the VSC-HVDC system is categorized into several sub-systems and the reliability data for the key components is discussed based on sources with academic and industrial backgrounds. The development of reliability evaluation methodologies is reviewed and the issues surrounding the different computation approaches are briefly analysed. A general VSC-HVDC reliability evaluation procedure is illustrated in this paper.

  14. Reliability of hunger-related assessments during 24-hour fasts and their relationship to body composition and subsequent energy compensation.

    PubMed

    Tinsley, Grant M; Moore, M Lane; Graybeal, Austin J

    2018-05-01

    Many diets employ regular periods of fasting that extend beyond a typical overnight fast (i.e. intermittent fasting [IF]). Evaluation of acute fasting responses provides information concerning the potential theoretical rationale for IF. The purpose of the present investigation was to assess the test-retest reliability of hunger-related variables during 24-hour fasts and the relationship between these variables and body composition, as well as subsequent energy intake (EI) after fasting. Eleven participants (6 F, 5 M) completed two 24-hour fasts after being provided a 3-day standardized weight-maintenance diet. From 16 to 24 h of fasting, participants were directly observed and provided hourly assessments of hunger, desire to eat (DTE), prospective food consumption (PFC), fullness and energy. After the fast, participants were allowed ad libitum food consumption, and compensation was calculated as EI relative to weight-maintenance energy needs. Test-retest reliability for hunger-related assessments at particular durations of fasting was evaluated using intraclass correlation coefficients (ICC), changes in dependent variables were evaluated using ANOVA with repeated measures, and relationships between variables were explored using bivariate correlations. At 16 h of fasting, the ICCs for all hunger-related assessments were statistically significant (r = 0.67-0.91; p ≤ 0.05). However, as the fast progressed, reliability varied substantially. When averaged across the nine measurements, the ICCs were: 0.81 (fullness), 0.74 (PFC), 0.67 (energy), 0.44 (DTE) and 0.36 (hunger). Body fat percentage was significantly correlated with changes in PFC (r = 0.62, p = 0.04), hunger (r = 0.66, p = 0.03), DTE (r = 0.71, p = 0.02), and fullness (r = -0.63, p = 0.04), but not energy (r = -0.16, p = 0.64). Average EI compensation was only 60% of weight-maintenance needs, but substantial variability was observed (7 to 110% compensation). Compensation was significantly correlated with changes in PFC (r = 0.72, p = 0.01), hunger (r = 0.63, p = 0.04) and DTE (r = 0.60, p = 0.05), but not fullness (r = 0.58, p = 0.06) or energy (r = 0.35, p = 0.29). Compensation and body fat percentage were not correlated (r = 0.03, p = 0.94). The percent of energy intake from fat and protein increased after the fast (29.9 to 37.3% and 13.8 to 16.8%; p < 0.05), while the percent of energy intake from carbohydrate decreased (56.4 to 46.0%; p = 0.02). These results may have implications for IF programs. It is possible that the implementation of multiple "test fasts," in which subjective variables and subsequent energy intake are evaluated, could be used to identify candidates who may be more likely to benefit from an IF program. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Effects of low-level radioactive-waste disposal on water chemistry in the unsaturated zone at a site near Sheffield, Illinois, 1982-84

    USGS Publications Warehouse

    Peters, C.A.; Striegl, Robert G.; Mills, P.C.; Healy, R.W.

    1992-01-01

    A 1982-84 field study defined the chemistry of water collected from the unsaturated zone at a low-level radioactive-waste disposal site near Sheffield, Bureau County, Ill. Chemical data were evaluated to determine the principal, naturally occurring geochemical reactions in the unsaturated zone and to evaluate waste-induced effects on pore-water chemistry. Samples of precipitation, unsaturated-zone pore water, and saturated-zone water were analyzed for specific conductance, pH, alkalinity, major cations and anions, dissolved organic carbon, gross alpha and beta radiation, and tritium. Little change in concentration of most major constituents in the unsaturated-zone water was observed with respect to depth or distance from disposal trenches. Tritium and dissolved organic carbon concentrations were, however, dependent on proximity to trenches. The primary reactions, both on-site and off-site, were carbonate and clay dissolution, cation exchange, and the oxidation of pyrite. The major difference between on-site and off-site inorganic water chemistry resulted from the removal of the Roxana Silt and the Radnor Till Member of the Glasford Formation from on-site. Off-site, the Roxana Silt contributed substantial quantities of sodium to solution from montmorillonite dissolution and associated cation-exchange reactions. The Radnor Till Member provided exchange surfaces for magnesium. Precipitation at the site had an ionic composition of calcium zinc sulfate and an average pH of 4.6. Within 0.3 meter of the land surface, infiltrating rainwater or snowmelt changed to an ionic composition of calcium sulfate off-site and calcium bicarbonate on-site and had an average pH of 7.9; below that depth, pH averaged 7.5 and the ionic composition generally was calcium magnesium bicarbonate. Alkalinity and specific conductance differed primarily according to composition of geologic materials. Tritium concentrations ranged from 0.2 (detection limit) to 1,380 nanocuries per liter. The methods of constructing, installing, and sampling with lysimeters were evaluated to ensure data reliability. These evaluations indicate that, with respect to most constituents, the samples retrieved from the lysimeters accurately represented pore-water chemistry.

  16. The development and psychometric validation of an instrument to evaluate nurses' attitudes towards communication with the patient (ACO).

    PubMed

    Giménez-Espert, María Del Carmen; Prado-Gascó, Vicente Javier

    2018-05-01

    Patient communication is a key skill for nurses involved in clinical care. Its measurement is a complex phenomenon that can be addressed through attitude evaluation. To develop and psychometrically test a measure of nurses' attitudes towards communication with patients (ACO), to study the relationship between these dimensions, and to analyse nursing attitudes. To develop and psychometrically test the ACO questionnaire. All hospitals in the province of Valencia were invited by e-mail to distribute the ACO instrument. Ten hospitals took part in the study. The study population was composed of a convenience sample of 400 hospital nurses on general or special services. The inclusion criteria were nurses at the selected centres who had previously provided an informed consent to participate. A literature review and expert consultation (N = 10) was used to develop the content of the questionnaire. The 62-item version of the instrument was applied to a convenience sample of 400 nurses between May 2015 and March 2016. Factor structure was evaluated with exploratory and confirmatory factor analysis (EFA, CFA), and reliability was evaluated with Cronbach's alpha, composite reliability (CR), and average variance extracted (AVE). The final instrument (ACO), composed of 25 items grouped into three attitude dimensions (cognitive, affective and behavioural), had good psychometric properties. In the study sample, nurses had a favourable attitude towards communication. The cognitive and affective dimensions of the ACO should be able to predict the behaviour dimension. The ACO is useful for evaluating current clinical practices, identifying educational needs and assessing the effectiveness of communication training or other interventions intended to improve communication. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Dynamic MRI to quantify musculoskeletal motion: A systematic review of concurrent validity and reliability, and perspectives for evaluation of musculoskeletal disorders.

    PubMed

    Borotikar, Bhushan; Lempereur, Mathieu; Lelievre, Mathieu; Burdin, Valérie; Ben Salem, Douraied; Brochard, Sylvain

    2017-01-01

    To report evidence for the concurrent validity and reliability of dynamic MRI techniques to evaluate in vivo joint and muscle mechanics, and to propose recommendations for their use in the assessment of normal and impaired musculoskeletal function. The search was conducted on articles published in Web of science, PubMed, Scopus, Academic search Premier, and Cochrane Library between 1990 and August 2017. Studies that reported the concurrent validity and/or reliability of dynamic MRI techniques for in vivo evaluation of joint or muscle mechanics were included after assessment by two independent reviewers. Selected articles were assessed using an adapted quality assessment tool and a data extraction process. Results for concurrent validity and reliability were categorized as poor, moderate, or excellent. Twenty articles fulfilled the inclusion criteria with a mean quality assessment score of 66% (±10.4%). Concurrent validity and/or reliability of eight dynamic MRI techniques were reported, with the knee being the most evaluated joint (seven studies). Moderate to excellent concurrent validity and reliability were reported for seven out of eight dynamic MRI techniques. Cine phase contrast and real-time MRI appeared to be the most valid and reliable techniques to evaluate joint motion, and spin tag for muscle motion. Dynamic MRI techniques are promising for the in vivo evaluation of musculoskeletal mechanics; however results should be evaluated with caution since validity and reliability have not been determined for all joints and muscles, nor for many pathological conditions.

  18. Use magnetic resonance imaging to assess articular cartilage

    PubMed Central

    Wang, Yuanyuan; Wluka, Anita E.; Jones, Graeme; Ding, Changhai

    2012-01-01

    Magnetic resonance imaging (MRI) enables a noninvasive, three-dimensional assessment of the entire joint, simultaneously allowing the direct visualization of articular cartilage. Thus, MRI has become the imaging modality of choice in both clinical and research settings of musculoskeletal diseases, particular for osteoarthritis (OA). Although radiography, the current gold standard for the assessment of OA, has had recent significant technical advances, radiographic methods have significant limitations when used to measure disease progression. MRI allows accurate and reliable assessment of articular cartilage which is sensitive to change, providing the opportunity to better examine and understand preclinical and very subtle early abnormalities in articular cartilage, prior to the onset of radiographic disease. MRI enables quantitative (cartilage volume and thickness) and semiquantitative assessment of articular cartilage morphology, and quantitative assessment of cartilage matrix composition. Cartilage volume and defects have demonstrated adequate validity, accuracy, reliability and sensitivity to change. They are correlated to radiographic changes and clinical outcomes such as pain and joint replacement. Measures of cartilage matrix composition show promise as they seem to relate to cartilage morphology and symptoms. MRI-derived cartilage measurements provide a useful tool for exploring the effect of modifiable factors on articular cartilage prior to clinical disease and identifying the potential preventive strategies. MRI represents a useful approach to monitoring the natural history of OA and evaluating the effect of therapeutic agents. MRI assessment of articular cartilage has tremendous potential for large-scale epidemiological studies of OA progression, and for clinical trials of treatment response to disease-modifying OA drugs. PMID:22870497

  19. Sensitivity of physical examination versus arthroscopy in diagnosing subscapularis tendon injury.

    PubMed

    Faruqui, Sami; Wijdicks, Coen; Foad, Abdullah

    2014-01-01

    The purpose of this study was to examine the accuracy of physical examination in the detection of subscapularis tendon tears and compare it with the gold standard of arthroscopy to determine whether clinical examination can reliably predict the presence of subscapularis tendon tears. This was a retrospective analysis of 52 patients (52 shoulders) who underwent arthroscopic subscapularis tendon repairs between September 2008 and April 2012. Positive findings on any combination of the belly press, lift-off, and bear hug tests constituted a positive physical examination result. There was a positive finding on physical examination in 42 of 52 patients. The sensitivity of the physical examination as a whole was 81%. The literature has shown that the belly press, bear hug, and lift-off tests are specific to the subscapularis tendon. To the authors’ knowledge, this is the first study to evaluate the sensitivity of these 3 separate clinical tests as a composite. Knowledge regarding the sensitivity of the subscapularis-specific physical examination as a composite can lead practitioners to implement all 3 components, even when 1 test has a negative finding, thus promoting a more thorough physical examination. Because unrepaired subscapularis tendon tears can result in poor outcomes in the repair of other rotator cuff tendons, a complete physical examination would be beneficial to patients with shoulder pathology. The authors conclude that physical examination, when performed consistently by an experienced practitioner, can reliably predict the presence of subscapularis tendon tears.

  20. Basic failure mechanisms in advanced composites

    NASA Technical Reports Server (NTRS)

    Mullin, J. V.; Mazzio, V. F.; Mehan, R. L.

    1972-01-01

    Failure mechanisms in carbon-epoxy composites are identified as a basis for more reliable prediction of the performance of these materials. The approach involves both the study of local fracture events in model specimens containing small groups of filaments and fractographic examination of high fiber content engineering composites. Emphasis is placed on the correlation of model specimen observations with gross fracture modes. The effects of fiber surface treatment, resin modification and fiber content are studied and acoustic emission methods are applied. Some effort is devoted to analysis of the failure process in composite/metal specimens.

  1. Composite lead for conducting an electrical current between 75--80K and 4. 5K temperatures

    DOEpatents

    Negm, Y.; Zimmerman, G.O.; Powers, R.E. Jr.; McConeghy, R.J.; Kaplan, A.

    1994-12-27

    A composite lead is provided which electrically links and conducts a current between about 75-80K and liquid helium temperature of about 4.5K. The composite lead may be employed singly or in multiples concurrently to provide conduction of electrical current from normal conductors and semi-conductors at room temperature to superconductors operating at 4.5K. In addition, a variety of organizational arrangements and assemblies are provided by which the mechanical strength and electrical reliability of the composite lead is maintained. 12 figures.

  2. Composite lead for conducting an electrical current between 75-80K and 4.5K temperatures

    DOEpatents

    Negm, Yehia; Zimmerman, George O.; Powers, Jr., Robert E.; McConeghy, Randy J.; Kaplan, Alvaro

    1994-12-27

    A composite lead is provided which electrically links and conducts a current between about 75-80K. and liquid helium temperature of about 4.5K. The composite lead may be employed singly or in multiples concurrently to provide conduction of electrical current from normal conductors and semi-conductors at room temperature to superconductors operating at 4.5K. In addition, a variety of organizationl arrangements and assemblies are provided by which the mechanical strength and electrical reliability of the composite lead is maintained.

  3. Performance Evaluation of Reliable Multicast Protocol for Checkout and Launch Control Systems

    NASA Technical Reports Server (NTRS)

    Shu, Wei Wennie; Porter, John

    2000-01-01

    The overall objective of this project is to study reliability and performance of Real Time Critical Network (RTCN) for checkout and launch control systems (CLCS). The major tasks include reliability and performance evaluation of Reliable Multicast (RM) package and fault tolerance analysis and design of dual redundant network architecture.

  4. Students' Evaluation Strategies in a Web Research Task: Are They Sensitive to Relevance and Reliability?

    ERIC Educational Resources Information Center

    Rodicio, Héctor García

    2015-01-01

    When searching and using resources on the Web, students have to evaluate Web pages in terms of relevance and reliability. This evaluation can be done in a more or less systematic way, by either considering deep or superficial cues of relevance and reliability. The goal of this study was to examine how systematic students are when evaluating Web…

  5. The Number of Feedbacks Needed for Reliable Evaluation. A Multilevel Analysis of the Reliability, Stability and Generalisability of Students' Evaluation of Teaching

    ERIC Educational Resources Information Center

    Rantanen, Pekka

    2013-01-01

    A multilevel analysis approach was used to analyse students' evaluation of teaching (SET). The low value of inter-rater reliability stresses that any solid conclusions on teaching cannot be made on the basis of single feedbacks. To assess a teacher's general teaching effectiveness, one needs to evaluate four randomly chosen course implementations.…

  6. Assessing the Reliability of Student Evaluations of Teaching: Choosing the Right Coefficient

    ERIC Educational Resources Information Center

    Morley, Donald

    2014-01-01

    Many of the studies used to support the claim that student evaluations of teaching are reliable measures of teaching effectiveness have frequently calculated inappropriate reliability coefficients. This paper points to three coefficients that would be appropriate depending on if student evaluations were used for formative or summative purposes.…

  7. Reliability prediction of ontology-based service compositions using Petri net and time series models.

    PubMed

    Li, Jia; Xia, Yunni; Luo, Xin

    2014-01-01

    OWL-S, one of the most important Semantic Web service ontologies proposed to date, provides a core ontological framework and guidelines for describing the properties and capabilities of their web services in an unambiguous, computer interpretable form. Predicting the reliability of composite service processes specified in OWL-S allows service users to decide whether the process meets the quantitative quality requirement. In this study, we consider the runtime quality of services to be fluctuating and introduce a dynamic framework to predict the runtime reliability of services specified in OWL-S, employing the Non-Markovian stochastic Petri net (NMSPN) and the time series model. The framework includes the following steps: obtaining the historical response times series of individual service components; fitting these series with a autoregressive-moving-average-model (ARMA for short) and predicting the future firing rates of service components; mapping the OWL-S process into a NMSPN model; employing the predicted firing rates as the model input of NMSPN and calculating the normal completion probability as the reliability estimate. In the case study, a comparison between the static model and our approach based on experimental data is presented and it is shown that our approach achieves higher prediction accuracy.

  8. Reliable and valid tools for measuring surgeons' teaching performance: residents' vs. self evaluation.

    PubMed

    Boerebach, Benjamin C M; Arah, Onyebuchi A; Busch, Olivier R C; Lombarts, Kiki M J M H

    2012-01-01

    In surgical education, there is a need for educational performance evaluation tools that yield reliable and valid data. This paper describes the development and validation of robust evaluation tools that provide surgeons with insight into their clinical teaching performance. We investigated (1) the reliability and validity of 2 tools for evaluating the teaching performance of attending surgeons in residency training programs, and (2) whether surgeons' self evaluation correlated with the residents' evaluation of those surgeons. We surveyed 343 surgeons and 320 residents as part of a multicenter prospective cohort study of faculty teaching performance in residency training programs. The reliability and validity of the SETQ (System for Evaluation Teaching Qualities) tools were studied using standard psychometric techniques. We then estimated the correlations between residents' and surgeons' evaluations. The response rate was 87% among surgeons and 84% among residents, yielding 2625 residents' evaluations and 302 self evaluations. The SETQ tools yielded reliable and valid data on 5 domains of surgical teaching performance, namely, learning climate, professional attitude towards residents, communication of goals, evaluation of residents, and feedback. The correlations between surgeons' self and residents' evaluations were low, with coefficients ranging from 0.03 for evaluation of residents to 0.18 for communication of goals. The SETQ tools for the evaluation of surgeons' teaching performance appear to yield reliable and valid data. The lack of strong correlations between surgeons' self and residents' evaluations suggest the need for using external feedback sources in informed self evaluation of surgeons. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  9. Development of an Extreme High Temperature n-type Ohmic Contact to Silicon Carbide

    NASA Technical Reports Server (NTRS)

    Evans, Laura J.; Okojie, Robert S.; Lukco, Dorothy

    2011-01-01

    We report on the initial demonstration of a tungsten-nickel (75:25 at. %) ohmic contact to silicon carbide (SiC) that performed for up to fifteen hours of heat treatment in argon at 1000 C. The transfer length method (TLM) test structure was used to evaluate the contacts. Samples showed consistent ohmic behavior with specific contact resistance values averaging 5 x 10-4 -cm2. The development of this contact metallization should allow silicon carbide devices to operate more reliably at the present maximum operating temperature of 600 C while potentially extending operations to 1000 C. Introduction Silicon Carbide (SiC) is widely recognized as one of the materials of choice for high temperature, harsh environment sensors and electronics due to its ability to survive and continue normal operation in such environments [1]. Sensors and electronics in SiC have been developed that are capable of operating at temperatures of 600 oC. However operating these devices at the upper reliability temperature threshold increases the potential for early degradation. Therefore, it is important to raise the reliability temperature ceiling higher, which would assure increased device reliability when operated at nominal temperature. There are also instances that require devices to operate and survive for prolonged periods of time above 600 oC [2, 3]. This is specifically needed in the area of hypersonic flight where robust sensors are needed to monitor vehicle performance at temperature greater than 1000 C, as well as for use in the thermomechanical characterization of high temperature materials (e.g. ceramic matrix composites). While SiC alone can withstand these temperatures, a major challenge is to develop reliable electrical contacts to the device itself in order to facilitate signal extraction

  10. Magnetic resonance imaging for diagnosis and assessment of cartilage defect repairs.

    PubMed

    Marlovits, Stefan; Mamisch, Tallal Charles; Vekszler, György; Resinger, Christoph; Trattnig, Siegfried

    2008-04-01

    Clinical magnetic resonance imaging (MRI) is the method of choice for the non-invasive evaluation of articular cartilage defects and the follow-up of cartilage repair procedures. The use of cartilage-sensitive sequences and a high spatial-resolution technique enables the evaluation of cartilage morphology even in the early stages of disease, as well as assessment of cartilage repair. Sequences that offer high contrast between articular cartilage and adjacent structures, such as the fat-suppressed, 3-dimensional, spoiled gradient-echo sequence and the fast spin-echo sequence, are accurate and reliable for evaluating intrachondral lesions and surface defects of articular cartilage. These sequences can also be performed together in reasonable examination times. In addition to morphology, new MRI techniques provide insight into the biochemical composition of articular cartilage and cartilage repair tissue. These techniques enable the diagnosis of early cartilage degeneration and help to monitor the effect and outcome of various surgical and non-surgical cartilage repair therapies.

  11. Computational Infrastructure for Engine Structural Performance Simulation

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.

    1997-01-01

    Select computer codes developed over the years to simulate specific aspects of engine structures are described. These codes include blade impact integrated multidisciplinary analysis and optimization, progressive structural fracture, quantification of uncertainties for structural reliability and risk, benefits estimation of new technology insertion and hierarchical simulation of engine structures made from metal matrix and ceramic matrix composites. Collectively these codes constitute a unique infrastructure readiness to credibly evaluate new and future engine structural concepts throughout the development cycle from initial concept, to design and fabrication, to service performance and maintenance and repairs, and to retirement for cause and even to possible recycling. Stated differently, they provide 'virtual' concurrent engineering for engine structures total-life-cycle-cost.

  12. Off-Shell Persistence of Composite Pions and Kaons

    DOE PAGES

    Qin, Si -Xue; Chen, Chen; Mezrag, Cedric; ...

    2018-01-17

    In order for a Sullivan-like process to provide reliable access to a meson target as t becomes spacelike, the pole associated with that meson should remain the dominant feature of the quarkantiquark scattering matrix and the wave function describing the related correlation must evolve slowly and smoothly. Using continuum methods for the strong-interaction bound-state problem, we explore and delineate the circumstances under which these conditions are satisfied: for the pion, this requires -t ≲ 0.6 GeV 2, whereas -t ≲ 0.9 GeV 2 will suffice for the kaon. Furthermore, these results should prove useful in evaluating the potential of numerousmore » experiments at existing and proposed facilities.« less

  13. Use of a structured functional evaluation process for independent medical evaluations of claimants presenting with disabling mental illness: rationale and design for a multi-center reliability study.

    PubMed

    Bachmann, Monica; de Boer, Wout; Schandelmaier, Stefan; Leibold, Andrea; Marelli, Renato; Jeger, Joerg; Hoffmann-Richter, Ulrike; Mager, Ralph; Schaad, Heinz; Zumbrunn, Thomas; Vogel, Nicole; Bänziger, Oskar; Busse, Jason W; Fischer, Katrin; Kunz, Regina

    2016-07-29

    Work capacity evaluations by independent medical experts are widely used to inform insurers whether injured or ill workers are capable of engaging in competitive employment. In many countries, evaluation processes lack a clearly structured approach, standardized instruments, and an explicit focus on claimants' functional abilities. Evaluation of subjective complaints, such as mental illness, present additional challenges in the determination of work capacity. We have therefore developed a process for functional evaluation of claimants with mental disorders which complements usual psychiatric evaluation. Here we report the design of a study to measure the reliability of our approach in determining work capacity among patients with mental illness applying for disability benefits. We will conduct a multi-center reliability study, in which 20 psychiatrists trained in our functional evaluation process will assess 30 claimants presenting with mental illness for eligibility to receive disability benefits [Reliability of Functional Evaluation in Psychiatry, RELY-study]. The functional evaluation process entails a five-step structured interview and a reporting instrument (Instrument of Functional Assessment in Psychiatry [IFAP]) to document the severity of work-related functional limitations. We will videotape all evaluations which will be viewed by three psychiatrists who will independently rate claimants' functional limitations. Our primary outcome measure is the evaluation of claimant's work capacity as a percentage (0 to 100 %), and our secondary outcomes are the 12 mental functions and 13 functional capacities assessed by the IFAP-instrument. Inter-rater reliability of four psychiatric experts will be explored using multilevel models to estimate the intraclass correlation coefficient (ICC). Additional analyses include subgroups according to mental disorder, the typicality of claimants, and claimant perceived fairness of the assessment process. We hypothesize that a structured functional approach will show moderate reliability (ICC ≥ 0.6) of psychiatric evaluation of work capacity. Enrollment of actual claimants with mental disorders referred for evaluation by disability/accident insurers will increase the external validity of our findings. Finding moderate levels of reliability, we will continue with a randomized trial to test the reliability of a structured functional approach versus evaluation-as-usual.

  14. Computer-Aided Reliability Estimation

    NASA Technical Reports Server (NTRS)

    Bavuso, S. J.; Stiffler, J. J.; Bryant, L. A.; Petersen, P. L.

    1986-01-01

    CARE III (Computer-Aided Reliability Estimation, Third Generation) helps estimate reliability of complex, redundant, fault-tolerant systems. Program specifically designed for evaluation of fault-tolerant avionics systems. However, CARE III general enough for use in evaluation of other systems as well.

  15. Biochemical methane potential prediction of plant biomasses: Comparing chemical composition versus near infrared methods and linear versus non-linear models.

    PubMed

    Godin, Bruno; Mayer, Frédéric; Agneessens, Richard; Gerin, Patrick; Dardenne, Pierre; Delfosse, Philippe; Delcarte, Jérôme

    2015-01-01

    The reliability of different models to predict the biochemical methane potential (BMP) of various plant biomasses using a multispecies dataset was compared. The most reliable prediction models of the BMP were those based on the near infrared (NIR) spectrum compared to those based on the chemical composition. The NIR predictions of local (specific regression and non-linear) models were able to estimate quantitatively, rapidly, cheaply and easily the BMP. Such a model could be further used for biomethanation plant management and optimization. The predictions of non-linear models were more reliable compared to those of linear models. The presentation form (green-dried, silage-dried and silage-wet form) of biomasses to the NIR spectrometer did not influence the performances of the NIR prediction models. The accuracy of the BMP method should be improved to enhance further the BMP prediction models. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Elemental Markers in Elasmobranchs: Effects of Environmental History and Growth on Vertebral Chemistry

    PubMed Central

    Smith, Wade D.; Miller, Jessica A.; Heppell, Selina S.

    2013-01-01

    Differences in the chemical composition of calcified skeletal structures (e.g. shells, otoliths) have proven useful for reconstructing the environmental history of many marine species. However, the extent to which ambient environmental conditions can be inferred from the elemental signatures within the vertebrae of elasmobranchs (sharks, skates, rays) has not been evaluated. To assess the relationship between water and vertebral elemental composition, we conducted two laboratory studies using round stingrays, Urobatis halleri, as a model species. First, we examined the effects of temperature (16°, 18°, 24°C) on vertebral elemental incorporation (Li/Ca, Mg/Ca, Mn/Ca, Zn/Ca, Sr/Ca, Ba/Ca). Second, we tested the relationship between water and subsequent vertebral elemental composition by manipulating dissolved barium concentrations (1x, 3x, 6x). We also evaluated the influence of natural variation in growth rate on elemental incorporation for both experiments. Finally, we examined the accuracy of classifying individuals to known environmental histories (temperature and barium treatments) using vertebral elemental composition. Temperature had strong, negative effects on the uptake of magnesium (DMg) and barium (DBa) and positively influenced manganese (DMn) incorporation. Temperature-dependent responses were not observed for lithium and strontium. Vertebral Ba/Ca was positively correlated with ambient Ba/Ca. Partition coefficients (DBa) revealed increased discrimination of barium in response to increased dissolved barium concentrations. There were no significant relationships between elemental incorporation and somatic growth or vertebral precipitation rates for any elements except Zn. Relationships between somatic growth rate and DZn were, however, inconsistent and inconclusive. Variation in the vertebral elemental signatures of U. halleri reliably distinguished individual rays from each treatment based on temperature (85%) and Ba exposure (96%) history. These results support the assumption that vertebral elemental composition reflects the environmental conditions during deposition and validates the use of vertebral elemental signatures as natural markers in an elasmobranch. Vertebral elemental analysis is a promising tool for the study of elasmobranch population structure, movement, and habitat use. PMID:24098320

  17. Elemental markers in elasmobranchs: effects of environmental history and growth on vertebral chemistry.

    PubMed

    Smith, Wade D; Miller, Jessica A; Heppell, Selina S

    2013-01-01

    Differences in the chemical composition of calcified skeletal structures (e.g. shells, otoliths) have proven useful for reconstructing the environmental history of many marine species. However, the extent to which ambient environmental conditions can be inferred from the elemental signatures within the vertebrae of elasmobranchs (sharks, skates, rays) has not been evaluated. To assess the relationship between water and vertebral elemental composition, we conducted two laboratory studies using round stingrays, Urobatis halleri, as a model species. First, we examined the effects of temperature (16°, 18°, 24°C) on vertebral elemental incorporation (Li/Ca, Mg/Ca, Mn/Ca, Zn/Ca, Sr/Ca, Ba/Ca). Second, we tested the relationship between water and subsequent vertebral elemental composition by manipulating dissolved barium concentrations (1x, 3x, 6x). We also evaluated the influence of natural variation in growth rate on elemental incorporation for both experiments. Finally, we examined the accuracy of classifying individuals to known environmental histories (temperature and barium treatments) using vertebral elemental composition. Temperature had strong, negative effects on the uptake of magnesium (DMg) and barium (DBa) and positively influenced manganese (DMn) incorporation. Temperature-dependent responses were not observed for lithium and strontium. Vertebral Ba/Ca was positively correlated with ambient Ba/Ca. Partition coefficients (DBa) revealed increased discrimination of barium in response to increased dissolved barium concentrations. There were no significant relationships between elemental incorporation and somatic growth or vertebral precipitation rates for any elements except Zn. Relationships between somatic growth rate and DZn were, however, inconsistent and inconclusive. Variation in the vertebral elemental signatures of U. halleri reliably distinguished individual rays from each treatment based on temperature (85%) and Ba exposure (96%) history. These results support the assumption that vertebral elemental composition reflects the environmental conditions during deposition and validates the use of vertebral elemental signatures as natural markers in an elasmobranch. Vertebral elemental analysis is a promising tool for the study of elasmobranch population structure, movement, and habitat use.

  18. Probabilistic Simulation of Combined Thermo-Mechanical Cyclic Fatigue in Composites

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.

    2011-01-01

    A methodology to compute probabilistically-combined thermo-mechanical fatigue life of polymer matrix laminated composites has been developed and is demonstrated. Matrix degradation effects caused by long-term environmental exposure and mechanical/thermal cyclic loads are accounted for in the simulation process. A unified time-temperature-stress-dependent multifactor-interaction relationship developed at NASA Glenn Research Center has been used to model the degradation/aging of material properties due to cyclic loads. The fast probability-integration method is used to compute probabilistic distribution of response. Sensitivities of fatigue life reliability to uncertainties in the primitive random variables (e.g., constituent properties, fiber volume ratio, void volume ratio, ply thickness, etc.) computed and their significance in the reliability-based design for maximum life is discussed. The effect of variation in the thermal cyclic loads on the fatigue reliability for a (0/+/-45/90)s graphite/epoxy laminate with a ply thickness of 0.127 mm, with respect to impending failure modes has been studied. The results show that, at low mechanical-cyclic loads and low thermal-cyclic amplitudes, fatigue life for 0.999 reliability is most sensitive to matrix compressive strength, matrix modulus, thermal expansion coefficient, and ply thickness. Whereas at high mechanical-cyclic loads and high thermal-cyclic amplitudes, fatigue life at 0.999 reliability is more sensitive to the shear strength of matrix, longitudinal fiber modulus, matrix modulus, and ply thickness.

  19. Probabilistic Simulation for Combined Cycle Fatigue in Composites

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.

    2010-01-01

    A methodology to compute probabilistic fatigue life of polymer matrix laminated composites has been developed and demonstrated. Matrix degradation effects caused by long term environmental exposure and mechanical/thermal cyclic loads are accounted for in the simulation process. A unified time-temperature-stress dependent multifactor interaction relationship developed at NASA Glenn Research Center has been used to model the degradation/aging of material properties due to cyclic loads. The fast probability integration method is used to compute probabilistic distribution of response. Sensitivities of fatigue life reliability to uncertainties in the primitive random variables (e.g., constituent properties, fiber volume ratio, void volume ratio, ply thickness, etc.) computed and their significance in the reliability-based design for maximum life is discussed. The effect of variation in the thermal cyclic loads on the fatigue reliability for a (0/+/- 45/90)s graphite/epoxy laminate with a ply thickness of 0.127 mm, with respect to impending failure modes has been studied. The results show that, at low mechanical cyclic loads and low thermal cyclic amplitudes, fatigue life for 0.999 reliability is most sensitive to matrix compressive strength, matrix modulus, thermal expansion coefficient, and ply thickness. Whereas at high mechanical cyclic loads and high thermal cyclic amplitudes, fatigue life at 0.999 reliability is more sensitive to the shear strength of matrix, longitudinal fiber modulus, matrix modulus, and ply thickness.

  20. Probabilistic Simulation of Combined Thermo-Mechanical Cyclic Fatigue in Composites

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.

    2010-01-01

    A methodology to compute probabilistically-combined thermo-mechanical fatigue life of polymer matrix laminated composites has been developed and is demonstrated. Matrix degradation effects caused by long-term environmental exposure and mechanical/thermal cyclic loads are accounted for in the simulation process. A unified time-temperature-stress-dependent multifactor-interaction relationship developed at NASA Glenn Research Center has been used to model the degradation/aging of material properties due to cyclic loads. The fast probability-integration method is used to compute probabilistic distribution of response. Sensitivities of fatigue life reliability to uncertainties in the primitive random variables (e.g., constituent properties, fiber volume ratio, void volume ratio, ply thickness, etc.) computed and their significance in the reliability-based design for maximum life is discussed. The effect of variation in the thermal cyclic loads on the fatigue reliability for a (0/+/-45/90)s graphite/epoxy laminate with a ply thickness of 0.127 mm, with respect to impending failure modes has been studied. The results show that, at low mechanical-cyclic loads and low thermal-cyclic amplitudes, fatigue life for 0.999 reliability is most sensitive to matrix compressive strength, matrix modulus, thermal expansion coefficient, and ply thickness. Whereas at high mechanical-cyclic loads and high thermal-cyclic amplitudes, fatigue life at 0.999 reliability is more sensitive to the shear strength of matrix, longitudinal fiber modulus, matrix modulus, and ply thickness.

  1. Adequacy assessment of composite generation and transmission systems incorporating wind energy conversion systems

    NASA Astrophysics Data System (ADS)

    Gao, Yi

    The development and utilization of wind energy for satisfying electrical demand has received considerable attention in recent years due to its tremendous environmental, social and economic benefits, together with public support and government incentives. Electric power generation from wind energy behaves quite differently from that of conventional sources. The fundamentally different operating characteristics of wind energy facilities therefore affect power system reliability in a different manner than those of conventional systems. The reliability impact of such a highly variable energy source is an important aspect that must be assessed when the wind power penetration is significant. The focus of the research described in this thesis is on the utilization of state sampling Monte Carlo simulation in wind integrated bulk electric system reliability analysis and the application of these concepts in system planning and decision making. Load forecast uncertainty is an important factor in long range planning and system development. This thesis describes two approximate approaches developed to reduce the number of steps in a load duration curve which includes load forecast uncertainty, and to provide reasonably accurate generating and bulk system reliability index predictions. The developed approaches are illustrated by application to two composite test systems. A method of generating correlated random numbers with uniform distributions and a specified correlation coefficient in the state sampling method is proposed and used to conduct adequacy assessment in generating systems and in bulk electric systems containing correlated wind farms in this thesis. The studies described show that it is possible to use the state sampling Monte Carlo simulation technique to quantitatively assess the reliability implications associated with adding wind power to a composite generation and transmission system including the effects of multiple correlated wind sites. This is an important development as it permits correlated wind farms to be incorporated in large practical system studies without requiring excessive increases in computer solution time. The procedures described in this thesis for creating monthly and seasonal wind farm models should prove useful in situations where time period models are required to incorporate scheduled maintenance of generation and transmission facilities. There is growing interest in combining deterministic considerations with probabilistic assessment in order to evaluate the quantitative system risk and conduct bulk power system planning. A relatively new approach that incorporates deterministic and probabilistic considerations in a single risk assessment framework has been designated as the joint deterministic-probabilistic approach. The research work described in this thesis illustrates that the joint deterministic-probabilistic approach can be effectively used to integrate wind power in bulk electric system planning. The studies described in this thesis show that the application of the joint deterministic-probabilistic method provides more stringent results for a system with wind power than the traditional deterministic N-1 method because the joint deterministic-probabilistic technique is driven by the deterministic N-1 criterion with an added probabilistic perspective which recognizes the power output characteristics of a wind turbine generator.

  2. Reliability models: the influence of model specification in generation expansion planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stremel, J.P.

    1982-10-01

    This paper is a critical evaluation of reliability methods used for generation expansion planning. It is shown that the methods for treating uncertainty are critical for determining the relative reliability value of expansion alternatives. It is also shown that the specification of the reliability model will not favor all expansion options equally. Consequently, the model is biased. In addition, reliability models should be augmented with an economic value of reliability (such as the cost of emergency procedures or energy not served). Generation expansion evaluations which ignore the economic value of excess reliability can be shown to be inconsistent. The conclusionsmore » are that, in general, a reliability model simplifies generation expansion planning evaluations. However, for a thorough analysis, the expansion options should be reviewed for candidates which may be unduly rejected because of the bias of the reliability model. And this implies that for a consistent formulation in an optimization framework, the reliability model should be replaced with a full economic optimization which includes the costs of emergency procedures and interruptions in the objective function.« less

  3. Construction and Evaluation of Reliability and Validity of Reasoning Ability Test

    ERIC Educational Resources Information Center

    Bhat, Mehraj A.

    2014-01-01

    This paper is based on the construction and evaluation of reliability and validity of reasoning ability test at secondary school students. In this paper an attempt was made to evaluate validity, reliability and to determine the appropriate standards to interpret the results of reasoning ability test. The test includes 45 items to measure six types…

  4. Reproducibility and relative validity of food group intake in a food frequency questionnaire developed for Nepalese diet.

    PubMed

    Shrestha, Archana; Koju, Rajendra Prasad; Beresford, Shirley A A; Chan, Kwun Chuen Gary; Connell, Frederik A; Karmacharya, Biraj Man; Shrestha, Pramita; Fitzpatrick, Annette L

    2017-08-01

    We developed a food frequency questionnaire (FFQ) designed to measure the dietary practices of adult Nepalese. The present study examined the validity and reproducibility of the FFQ. To evaluate the reproducibility of the FFQ, 116 subjects completed two 115-item FFQ across a four-month interval. Six 24-h dietary recalls were collected (1 each month) to assess the validity of the FFQ. Seven major food groups and 23 subgroups were clustered from the FFQ based on macronutrient composition. Spearman correlation coefficients evaluating reproducibility for all food groups were greater than 0.5, with the exceptions of oil. The correlations varied from 0.41 (oil) to 0.81 (vegetables). All crude spearman coefficients for validity were greater than 0.5 except for dairy products, pizzas/pastas and sausage/burgers. The FFQ was found to be reliable and valid for ranking the intake of food groups for Nepalese dietary intake.

  5. Prediction of the compression ratio for municipal solid waste using decision tree.

    PubMed

    Heshmati R, Ali Akbar; Mokhtari, Maryam; Shakiba Rad, Saeed

    2014-01-01

    The compression ratio of municipal solid waste (MSW) is an essential parameter for evaluation of waste settlement and landfill design. However, no appropriate model has been proposed to estimate the waste compression ratio so far. In this study, a decision tree method was utilized to predict the waste compression ratio (C'c). The tree was constructed using Quinlan's M5 algorithm. A reliable database retrieved from the literature was used to develop a practical model that relates C'c to waste composition and properties, including dry density, dry weight water content, and percentage of biodegradable organic waste using the decision tree method. The performance of the developed model was examined in terms of different statistical criteria, including correlation coefficient, root mean squared error, mean absolute error and mean bias error, recommended by researchers. The obtained results demonstrate that the suggested model is able to evaluate the compression ratio of MSW effectively.

  6. Quantitative Evaluation of Delamination in Composites Using Lamb Waves

    NASA Astrophysics Data System (ADS)

    Michalcová, L.; Hron, R.

    2018-03-01

    Ultrasonic guided wave monitoring has become very popular in the area of structural health monitoring (SHM) of aerospace structures. Any possible type of damage must be reliably assessed. The paper deals with delamination length determination in DCB specimens using Lamb waves. An analytical equation based on the velocity dependence on variable thickness is utilized. The group velocity of the fundamental antisymmetric A0 mode rapidly changes in a particular range of the frequency-thickness product. Using the same actuation frequency the propagation velocity is different for delaminated structure. Lamb wave based delamination lengths were compared to the visually determined lengths. The method of the wave velocity determination proved to be essential. More accurate results were achieved by tracking the maximum amplitude of A0 mode than the first signal arrival. These findings are considered as the basis for the damage evaluation of complex structures.

  7. Field reliability of competency and sanity opinions: A systematic review and meta-analysis.

    PubMed

    Guarnera, Lucy A; Murrie, Daniel C

    2017-06-01

    We know surprisingly little about the interrater reliability of forensic psychological opinions, even though courts and other authorities have long called for known error rates for scientific procedures admitted as courtroom testimony. This is particularly true for opinions produced during routine practice in the field, even for some of the most common types of forensic evaluations-evaluations of adjudicative competency and legal sanity. To address this gap, we used meta-analytic procedures and study space methodology to systematically review studies that examined the interrater reliability-particularly the field reliability-of competency and sanity opinions. Of 59 identified studies, 9 addressed the field reliability of competency opinions and 8 addressed the field reliability of sanity opinions. These studies presented a wide range of reliability estimates; pairwise percentage agreements ranged from 57% to 100% and kappas ranged from .28 to 1.0. Meta-analytic combinations of reliability estimates obtained by independent evaluators returned estimates of κ = .49 (95% CI: .40-.58) for competency opinions and κ = .41 (95% CI: .29-.53) for sanity opinions. This wide range of reliability estimates underscores the extent to which different evaluation contexts tend to produce different reliability rates. Unfortunately, our study space analysis illustrates that available field reliability studies typically provide little information about contextual variables crucial to understanding their findings. Given these concerns, we offer suggestions for improving research on the field reliability of competency and sanity opinions, as well as suggestions for improving reliability rates themselves. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  8. Evaluation of the Transit Reliability Information Program

    DOT National Transportation Integrated Search

    1982-06-01

    This report presents an evaluation of the rail portion of the Transit Reliability Information Program (TRIP), which was designed to collect and analyze equipment reliability data on U.S. transit systems. This assessment was conducted at the end of it...

  9. Probabilistic Composite Design

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.

    1997-01-01

    Probabilistic composite design is described in terms of a computational simulation. This simulation tracks probabilistically the composite design evolution from constituent materials, fabrication process, through composite mechanics and structural components. Comparisons with experimental data are provided to illustrate selection of probabilistic design allowables, test methods/specimen guidelines, and identification of in situ versus pristine strength, For example, results show that: in situ fiber tensile strength is 90% of its pristine strength; flat-wise long-tapered specimens are most suitable for setting ply tensile strength allowables: a composite radome can be designed with a reliability of 0.999999; and laminate fatigue exhibits wide-spread scatter at 90% cyclic-stress to static-strength ratios.

  10. Composite structural materials. [aircraft structures

    NASA Technical Reports Server (NTRS)

    Ansell, G. S.; Loewy, R. G.; Wiberley, S. E.

    1980-01-01

    The use of filamentary composite materials in the design and construction of primary aircraft structures is considered with emphasis on efforts to develop advanced technology in the areas of physical properties, structural concepts and analysis, manufacturing, and reliability and life prediction. The redesign of a main spar/rib region on the Boeing 727 elevator near its actuator attachment point is discussed. A composite fabrication and test facility is described as well as the use of minicomputers for computer aided design. Other topics covered include (1) advanced structural analysis methids for composites; (2) ultrasonic nondestructive testing of composite structures; (3) optimum combination of hardeners in the cure of epoxy; (4) fatigue in composite materials; (5) resin matrix characterization and properties; (6) postbuckling analysis of curved laminate composite panels; and (7) acoustic emission testing of composite tensile specimens.

  11. Laser cutting plastic materials

    NASA Astrophysics Data System (ADS)

    Vancleave, R. A.

    1980-08-01

    A 1000 watt CO2 laser was demonstrated as a reliable production machine tool for cutting of plastics, high strength reinforced composites, and other nonmetals. More than 40 different plastics were laser cut, and the results are tabulated. Applications for laser cutting described include fiberglass reinforced laminates, Kevlar/epoxy composites, fiberglass reinforced phenolics, nylon/epoxy laminates, ceramics, and disposal tooling made from acrylic.

  12. The life times of polymer composites in construction

    NASA Astrophysics Data System (ADS)

    Meier, Urs

    2016-05-01

    This paper discusses examples that prove the long-term reliability of Fiber Reinforced Polymers (FRP) under extreme loading conditions and outdoor weathering. Results of polymer/steel-composite anchorage systems, Glass Fiber Reinforced Polymer (GFRP) plates and shells, GFRP box girders, Carbon Fiber Reinforced Polymer (CFRP) post-tensioning tendons and CFRP stays are going to be presented.

  13. Inorganic elemental compositions of commercial multivitamin/mineral dietary supplements: application of collision/reaction cell inductively coupled-mass spectroscopy

    USDA-ARS?s Scientific Manuscript database

    Microwave digestion followed by analysis using ICP-MS has been shown to be a simple, fast reliable method for the multi-element determination in multivitamin/mineral dietary supplements (MVM). A study of 35 popular MVM dietary supplements revealed that composition and levels varied among products, a...

  14. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF YARD COMPOSITE SOIL SAMPLES (UA-F-5.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of yard composite soil samples in the field. This procedure was followed to ensure consistent and reliable collection of outdoor soil samples during the Arizona NHEXAS project and the "Border" study. ...

  15. Structural composite panel performance under long-term load

    Treesearch

    Theodore L. Laufenberg

    1988-01-01

    Information on the performance of wood-based structural composite panels under long-term load is currently needed to permit their use in engineered assemblies and systems. A broad assessment of the time-dependent properties of panels is critical for creating databases and models of the creep-rupture phenomenon that lead to reliability-based design procedures. This...

  16. Dynamic MRI to quantify musculoskeletal motion: A systematic review of concurrent validity and reliability, and perspectives for evaluation of musculoskeletal disorders

    PubMed Central

    Lempereur, Mathieu; Lelievre, Mathieu; Burdin, Valérie; Ben Salem, Douraied; Brochard, Sylvain

    2017-01-01

    Purpose To report evidence for the concurrent validity and reliability of dynamic MRI techniques to evaluate in vivo joint and muscle mechanics, and to propose recommendations for their use in the assessment of normal and impaired musculoskeletal function. Materials and methods The search was conducted on articles published in Web of science, PubMed, Scopus, Academic search Premier, and Cochrane Library between 1990 and August 2017. Studies that reported the concurrent validity and/or reliability of dynamic MRI techniques for in vivo evaluation of joint or muscle mechanics were included after assessment by two independent reviewers. Selected articles were assessed using an adapted quality assessment tool and a data extraction process. Results for concurrent validity and reliability were categorized as poor, moderate, or excellent. Results Twenty articles fulfilled the inclusion criteria with a mean quality assessment score of 66% (±10.4%). Concurrent validity and/or reliability of eight dynamic MRI techniques were reported, with the knee being the most evaluated joint (seven studies). Moderate to excellent concurrent validity and reliability were reported for seven out of eight dynamic MRI techniques. Cine phase contrast and real-time MRI appeared to be the most valid and reliable techniques to evaluate joint motion, and spin tag for muscle motion. Conclusion Dynamic MRI techniques are promising for the in vivo evaluation of musculoskeletal mechanics; however results should be evaluated with caution since validity and reliability have not been determined for all joints and muscles, nor for many pathological conditions. PMID:29232401

  17. Evaluation of maternal and neonatal hospital care: quality index of completeness

    PubMed Central

    da Silva, Ana Lúcia Andrade; Mendes, Antonio da Cruz Gouveia; Miranda, Gabriella Morais Duarte; de Sá, Domicio Aurélio; de Souza, Wayner Vieira; Lyra, Tereza Maciel

    2014-01-01

    OBJECTIVE Develop an index to evaluate the maternal and neonatal hospital care of the Brazilian Unified Health System. METHODS This descriptive cross-sectional study of national scope was based on the structure-process-outcome framework proposed by Donabedian and on comprehensive health care. Data from the Hospital Information System and the National Registry of Health Establishments were used. The maternal and neonatal network of Brazilian Unified Health System consisted of 3,400 hospitals that performed at least 12 deliveries in 2009 or whose number of deliveries represented 10.0% or more of the total admissions in 2009. Relevance and reliability were defined as criteria for the selection of variables. Simple and composite indicators and the index of completeness were constructed and evaluated, and the distribution of maternal and neonatal hospital care was assessed in different regions of the country. RESULTS A total of 40 variables were selected, from which 27 single indicators, five composite indicators, and the index of completeness of care were built. Composite indicators were constructed by grouping simple indicators and included the following variables: hospital size, level of complexity, delivery care practice, recommended hospital practice, and epidemiological practice. The index of completeness of care grouped the five variables and classified them in ascending order, thereby yielding five levels of completeness of maternal and neonatal hospital care: very low, low, intermediate, high, and very high. The hospital network was predominantly of small size and low complexity, with inadequate child delivery care and poor development of recommended and epidemiological practices. The index showed that more than 80.0% hospitals had a low index of completeness of care and that most qualified heath care services were concentrated in the more developed regions of the country. CONCLUSIONS The index of completeness proved to be of great value for monitoring the maternal and neonatal hospital care of Brazilian Unified Health System and indicated that the quality of health care was unsatisfactory. However, its application does not replace specific evaluations. PMID:25210827

  18. Evaluation of angiogram visualization methods for fast and reliable aneurysm diagnosis

    NASA Astrophysics Data System (ADS)

    Lesar, Žiga; Bohak, Ciril; Marolt, Matija

    2015-03-01

    In this paper we present the results of an evaluation of different visualization methods for angiogram volumetric data-ray casting, marching cubes, and multi-level partition of unity implicits. There are several options available with ray-casting: isosurface extraction, maximum intensity projection and alpha compositing, each producing fundamentally different results. Different visualization methods are suitable for different needs, so this choice is crucial in diagnosis and decision making processes. We also evaluate visual effects such as ambient occlusion, screen space ambient occlusion, and depth of field. Some visualization methods include transparency, so we address the question of relevancy of this additional visual information. We employ transfer functions to map data values to color and transparency, allowing us to view or hide particular tissues. All the methods presented in this paper were developed using OpenCL, striving for real-time rendering and quality interaction. An evaluation has been conducted to assess the suitability of the visualization methods. Results show superiority of isosurface extraction with ambient occlusion effects. Visual effects may positively or negatively affect perception of depth, motion, and relative positions in space.

  19. Evaluation of Ages in the Lunar Highlands with Implications for the Evolution of the Moon

    NASA Astrophysics Data System (ADS)

    Borg, L. E.; Gaffney, A. M.; Carlson, R. W.

    2012-12-01

    The lunar highlands are composed of rocks from the ferroan anorthosite (FAN) and Mg-suites. These samples have been extensively studied because they record most of the major events associated with the formation and evolution of the Earth's Moon. Despite their potential to constrain the timing of these events, chronologic investigations are often ambiguous; in most cases because absolute ages and/or initial isotopic compositions are inconsistent with stratigraphic and petrologic relationships of various rock suites inferred from mineralogical and geochemical studies. The problem is exacerbated by the fact that most samples are difficult to date due to their small size and nearly monomineralic nature, as well as isotopic disturbances associated with impacts. Here several criteria are used to assess the reliability of lunar ages, including: (1) concordance between multiple chronometers, (2) linearity of individual isochrons, (3) resistance of the chronometers to disruption by impact or contamination, (4) consistency between initial isotopic compositions and the petrogenisis of samples, and (5) reasonableness of the elemental concentrations of mineral fractions. If only those samples that meet 4 out of 5 of these criteria are used to constrain lunar chronology many of the apparent conflicts between chronometry and petrology disappear. For example, this analysis demonstrates that the most ancient ages reported for lunar samples are some of the least reliable. The oldest ages determined on both FAN and Mg-suite highland rocks with confidence are in fact ~4.35 Ga. This age is concordant with 142Nd mare source formation ages and a peak in zircon ages, suggesting it represents a major event at ~4.35 Ga. In contrast, several apparently reliable KREEP model ages are older at ~4.48 Ga. If these older model ages are correct, they may represent the solidification age of the Moon, whereas the 4.35 Ga event could reflect secondary magmatism and cumulate re-equilibration associated with density overturn of primordial magma ocean cumulates.

  20. Reliability and risk assessment of structures

    NASA Technical Reports Server (NTRS)

    Chamis, C. C.

    1991-01-01

    Development of reliability and risk assessment of structural components and structures is a major activity at Lewis Research Center. It consists of five program elements: (1) probabilistic loads; (2) probabilistic finite element analysis; (3) probabilistic material behavior; (4) assessment of reliability and risk; and (5) probabilistic structural performance evaluation. Recent progress includes: (1) the evaluation of the various uncertainties in terms of cumulative distribution functions for various structural response variables based on known or assumed uncertainties in primitive structural variables; (2) evaluation of the failure probability; (3) reliability and risk-cost assessment; and (4) an outline of an emerging approach for eventual certification of man-rated structures by computational methods. Collectively, the results demonstrate that the structural durability/reliability of man-rated structural components and structures can be effectively evaluated by using formal probabilistic methods.

  1. Soft error evaluation and vulnerability analysis in Xilinx Zynq-7010 system-on chip

    NASA Astrophysics Data System (ADS)

    Du, Xuecheng; He, Chaohui; Liu, Shuhuan; Zhang, Yao; Li, Yonghong; Xiong, Ceng; Tan, Pengkang

    2016-09-01

    Radiation-induced soft errors are an increasingly important threat to the reliability of modern electronic systems. In order to evaluate system-on chip's reliability and soft error, the fault tree analysis method was used in this work. The system fault tree was constructed based on Xilinx Zynq-7010 All Programmable SoC. Moreover, the soft error rates of different components in Zynq-7010 SoC were tested by americium-241 alpha radiation source. Furthermore, some parameters that used to evaluate the system's reliability and safety were calculated using Isograph Reliability Workbench 11.0, such as failure rate, unavailability and mean time to failure (MTTF). According to fault tree analysis for system-on chip, the critical blocks and system reliability were evaluated through the qualitative and quantitative analysis.

  2. Definition, reporting, and interpretation of composite outcomes in clinical trials: systematic review

    PubMed Central

    Cordoba, Gloria; Schwartz, Lisa; Woloshin, Steven; Bae, Harold

    2010-01-01

    Objective To study how composite outcomes, which have combined several components into a single measure, are defined, reported, and interpreted. Design Systematic review of parallel group randomised clinical trials published in 2008 reporting a binary composite outcome. Two independent observers extracted the data using a standardised data sheet, and two other observers, blinded to the results, selected the most important component. Results Of 40 included trials, 29 (73%) were about cardiovascular topics and 24 (60%) were entirely or partly industry funded. Composite outcomes had a median of three components (range 2–9). Death or cardiovascular death was the most important component in 33 trials (83%). Only one trial provided a good rationale for the choice of components. We judged that the components were not of similar importance in 28 trials (70%); in 20 of these, death was combined with hospital admission. Other major problems were change in the definition of the composite outcome between the abstract, methods, and results sections (13 trials); missing, ambiguous, or uninterpretable data (9 trials); and post hoc construction of composite outcomes (4 trials). Only 24 trials (60%) provided reliable estimates for both the composite and its components, and only six trials (15%) had components of similar, or possibly similar, clinical importance and provided reliable estimates. In 11 of 16 trials with a statistically significant composite, the abstract conclusion falsely implied that the effect applied also to the most important component. Conclusions The use of composite outcomes in trials is problematic. Components are often unreasonably combined, inconsistently defined, and inadequately reported. These problems will leave many readers confused, often with an exaggerated perception of how well interventions work. PMID:20719825

  3. Definition, reporting, and interpretation of composite outcomes in clinical trials: systematic review.

    PubMed

    Cordoba, Gloria; Schwartz, Lisa; Woloshin, Steven; Bae, Harold; Gøtzsche, Peter C

    2010-08-18

    To study how composite outcomes, which have combined several components into a single measure, are defined, reported, and interpreted. Systematic review of parallel group randomised clinical trials published in 2008 reporting a binary composite outcome. Two independent observers extracted the data using a standardised data sheet, and two other observers, blinded to the results, selected the most important component. Of 40 included trials, 29 (73%) were about cardiovascular topics and 24 (60%) were entirely or partly industry funded. Composite outcomes had a median of three components (range 2-9). Death or cardiovascular death was the most important component in 33 trials (83%). Only one trial provided a good rationale for the choice of components. We judged that the components were not of similar importance in 28 trials (70%); in 20 of these, death was combined with hospital admission. Other major problems were change in the definition of the composite outcome between the abstract, methods, and results sections (13 trials); missing, ambiguous, or uninterpretable data (9 trials); and post hoc construction of composite outcomes (4 trials). Only 24 trials (60%) provided reliable estimates for both the composite and its components, and only six trials (15%) had components of similar, or possibly similar, clinical importance and provided reliable estimates. In 11 of 16 trials with a statistically significant composite, the abstract conclusion falsely implied that the effect applied also to the most important component. The use of composite outcomes in trials is problematic. Components are often unreasonably combined, inconsistently defined, and inadequately reported. These problems will leave many readers confused, often with an exaggerated perception of how well interventions work.

  4. Mental imagery boosts music compositional creativity.

    PubMed

    Wong, Sarah Shi Hui; Lim, Stephen Wee Hun

    2017-01-01

    We empirically investigated the effect of mental imagery on young children's music compositional creativity. Children aged 5 to 8 years participated in two music composition sessions. In the control session, participants based their composition on a motif that they had created using a sequence of letter names. In the mental imagery session, participants were given a picture of an animal and instructed to imagine the animal's sounds and movements, before incorporating what they had imagined into their composition. Six expert judges independently rated all music compositions on creativity based on subjective criteria (consensual assessment). Reliability analyses indicated that the expert judges demonstrated a high level of agreement in their ratings. The mental imagery compositions received significantly higher creativity ratings by the expert judges than did the control compositions. These results provide evidence for the effectiveness of mental imagery in enhancing young children's music compositional creativity.

  5. Teamwork as an Essential Component of High-Reliability Organizations

    PubMed Central

    Baker, David P; Day, Rachel; Salas, Eduardo

    2006-01-01

    Organizations are increasingly becoming dynamic and unstable. This evolution has given rise to greater reliance on teams and increased complexity in terms of team composition, skills required, and degree of risk involved. High-reliability organizations (HROs) are those that exist in such hazardous environments where the consequences of errors are high, but the occurrence of error is extremely low. In this article, we argue that teamwork is an essential component of achieving high reliability particularly in health care organizations. We describe the fundamental characteristics of teams, review strategies in team training, demonstrate the criticality of teamwork in HROs and finally, identify specific challenges the health care community must address to improve teamwork and enhance reliability. PMID:16898980

  6. Deep eutectic solvent formation: a structural view using molecular dynamics simulations with classical force fields

    NASA Astrophysics Data System (ADS)

    Mainberger, Sebastian; Kindlein, Moritz; Bezold, Franziska; Elts, Ekaterina; Minceva, Mirjana; Briesen, Heiko

    2017-06-01

    Deep eutectic solvents (DES) have gained a reputation as inexpensive and easy to handle ionic liquid analogues. This work employs molecular dynamics (MD) to simulate a variety of DES. The hydrogen bond acceptor (HBA) choline chloride was paired with the hydrogen bond donors (HBD) glycerol, 1,4-butanediol, and levulinic acid. Levulinic acid was also paired with the zwitterionic HBA betaine. In order to evaluate the reliability of data MD simulations can provide for DES, two force fields were compared: the Merck Molecular Force Field and the General Amber Force Field with two different sets of partial charges for the latter. The force fields were evaluated by comparing available experimental thermodynamic and transport properties against simulated values. Structural analysis was performed on the eutectic systems and compared to non-eutectic compositions. All force fields could be validated against certain experimental properties, but performance varied depending on the system and property in question. While extensive hydrogen bonding was found for all systems, details about the contribution of individual groups strongly varied among force fields. Interaction potentials revealed that HBA-HBA interactions weaken linearly with increasing HBD ratio, while HBD-HBD interactions grew disproportionally in magnitude, which might hint at the eutectic composition of a system.

  7. Fundamental Studies of Adhesion of Dust to PV Module Surfaces: Chemical and Physical Relationships at the Microscale

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kazmerski, Lawrence L.; Diniz, Antonia Sonia A. C.; Maia, Cristiana Brasil

    Photovoltaic (PV) module soiling is a growing area of concern for performance and reliability. This paper provides evaluations of the fundamental interactions of dust/soiling particles with several PV module surfaces. The purpose is to investigate the basic mechanisms involving the chemistry, morphology, and resulting particle adhesion to the first photon-incident surface. The evaluation and mapping of the chemistry and composition of single dust particles collected from operating PV module surfaces are presented. The first correlated direct measurements of the adhesive force of individual grains from field-operating collectors on identical PV module glass are reported, including correlations with specific compositions. Specialmore » microscale atomic force microscopy techniques are adapted to determine the force between the particle and the module glass surface. Results are presented for samples under dry and moisture-exposed conditions, confirming the effects of cementation for surfaces having soluble mineral and/or organic concentrations. Additionally, the effects of hydrocarbon fuels on the enhanced bonding of soiling particles to surfaces are determined for samples from urban and highly trafficked regions. Comparisons between glass and dust-mitigating superhydrophobic and superhydrophilic coatings are presented. Potential limitations of this proximal probe technique are discussed in terms of results and initial proof-of-concept experiments.« less

  8. Developing a Measure of General Academic Ability: An Application of Maximal Reliability and Optimal Linear Combination to High School Students' Scores

    ERIC Educational Resources Information Center

    Dimitrov, Dimiter M.; Raykov, Tenko; AL-Qataee, Abdullah Ali

    2015-01-01

    This article is concerned with developing a measure of general academic ability (GAA) for high school graduates who apply to colleges, as well as with the identification of optimal weights of the GAA indicators in a linear combination that yields a composite score with maximal reliability and maximal predictive validity, employing the framework of…

  9. Space debris mitigation - engineering strategies

    NASA Astrophysics Data System (ADS)

    Taylor, E.; Hammond, M.

    The problem of space debris pollution is acknowledged to be of growing concern by space agencies, leading to recent activities in the field of space debris mitigation. A review of the current (and near-future) mitigation guidelines, handbooks, standards and licensing procedures has identified a number of areas where further work is required. In order for space debris mitigation to be implemented in spacecraft manufacture and operation, the authors suggest that debris-related criteria need to become design parameters (following the same process as applied to reliability and radiation). To meet these parameters, spacecraft manufacturers and operators will need processes (supported by design tools and databases and implementation standards). A particular aspect of debris mitigation, as compared with conventional requirements (e.g. radiation and reliability) is the current and near-future national and international regulatory framework and associated liability aspects. A framework for these implementation standards is presented, in addition to results of in-house research and development on design tools and databases (including collision avoidance in GTO and SSTO and evaluation of failure criteria on composite and aluminium structures).

  10. Confirmatory factor analysis of different versions of the Body Shape Questionnaire applied to Brazilian university students.

    PubMed

    da Silva, Wanderson Roberto; Dias, Juliana Chioda Ribeiro; Maroco, João; Campos, Juliana Alvares Duarte Bonini

    2014-09-01

    This study aimed at evaluating the validity, reliability, and factorial invariance of the complete (34-item) and shortened (8-item and 16-item) versions of the Body Shape Questionnaire (BSQ) when applied to Brazilian university students. A total of 739 female students with a mean age of 20.44 (standard deviation=2.45) years participated. Confirmatory factor analysis was conducted to verify the degree to which the one-factor structure satisfies the proposal for the BSQ's expected structure. Two items of the 34-item version were excluded because they had factor weights (λ)<40. All models had adequate convergent validity (average variance extracted=.43-.58; composite reliability=.85-.97) and internal consistency (α=.85-.97). The 8-item B version was considered the best shortened BSQ version (Akaike information criterion=84.07, Bayes information criterion=157.75, Browne-Cudeck criterion=84.46), with strong invariance for independent samples (Δχ(2)λ(7)=5.06, Δχ(2)Cov(8)=5.11, Δχ(2)Res(16)=19.30). Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Evaluation of the Gratitude Questionnaire in a Chinese Sample of Adults: Factorial Validity, Criterion-Related Validity, and Measurement Invariance Across Sex

    PubMed Central

    Kong, Feng; You, Xuqun; Zhao, Jingjing

    2017-01-01

    The Gratitude Questionnaire (GQ; McCullough et al., 2002) is one of the most widely used instruments to assess dispositional gratitude. The purpose of this study was to validate a Chinese version of the GQ by examining internal consistency, factor structure, convergent validity, and measurement invariance across sex. A total of 1151 Chinese adults were recruited to complete the GQ, Positive Affect and Negative Affect Scales, and Satisfaction with Life Scale. Confirmatory factor analysis indicated that the original unidimensional model fitted well, which is in accordance with the findings in Western populations. Furthermore, the GQ had satisfactory composite reliability and criterion-related validity with measures of life satisfaction and affective well-being. Evidence of configural, metric and scalar invariance across sex was obtained. Tests of the latent mean differences found females had higher latent mean scores than males. These findings suggest that the Chinese version of GQ is a reliable and valid tool for measuring dispositional gratitude and can generally be utilized across sex in the Chinese context. PMID:28919873

  12. Evaluation of the Gratitude Questionnaire in a Chinese Sample of Adults: Factorial Validity, Criterion-Related Validity, and Measurement Invariance Across Sex.

    PubMed

    Kong, Feng; You, Xuqun; Zhao, Jingjing

    2017-01-01

    The Gratitude Questionnaire (GQ; McCullough et al., 2002) is one of the most widely used instruments to assess dispositional gratitude. The purpose of this study was to validate a Chinese version of the GQ by examining internal consistency, factor structure, convergent validity, and measurement invariance across sex. A total of 1151 Chinese adults were recruited to complete the GQ, Positive Affect and Negative Affect Scales, and Satisfaction with Life Scale. Confirmatory factor analysis indicated that the original unidimensional model fitted well, which is in accordance with the findings in Western populations. Furthermore, the GQ had satisfactory composite reliability and criterion-related validity with measures of life satisfaction and affective well-being. Evidence of configural, metric and scalar invariance across sex was obtained. Tests of the latent mean differences found females had higher latent mean scores than males. These findings suggest that the Chinese version of GQ is a reliable and valid tool for measuring dispositional gratitude and can generally be utilized across sex in the Chinese context.

  13. Design and performance testing of a real-time PCR assay for sensitive and reliable direct quantification of Brettanomyces in wine.

    PubMed

    Tessonnière, H; Vidal, S; Barnavon, L; Alexandre, H; Remize, F

    2009-02-28

    Because the yeast Brettanomyces produces volatile phenols and acetic acid, it is responsible for wine spoilage. The uncontrolled accumulation of these molecules in wine leads to sensorial defects that compromise wine quality. The need for a rapid, specific, sensitive and reliable method to detect this spoilage yeast has increased over the last decade. All these requirements are met by real-time PCR. We here propose improvements of existing methods to enhance the robustness of the assay. Six different protocols to isolate DNA from a wine and three PCR mix compositions were tested, and the best method was selected. Insoluble PVPP addition during DNA extraction by a classical phenol:chloroform protocol succeeded in the relief of PCR inhibitors from wine. We developed an internal control which was efficient to avoid false negative results due to decreases in the efficiency of DNA isolation and/or amplification. The method was evaluated by an intra-laboratory study for its specificity, linearity, repeatability and reproducibility. A standard curve was established from 14 different wines artificially inoculated. The quantification limit was 31 cfu/mL.

  14. Reliability and Availability Evaluation Program Manual.

    DTIC Science & Technology

    1982-11-01

    research and development. The manual’s purpose was to provide a practical method for making reliability measurements, measurements directly related to... Research , Development, Test and Evaluation. RMA Reliability, Maintainability and Availability. R&R Repair and Refurbishment, Repair and Replacement, etc...length. phenomena such as mechanical wear and A number of researchers in the reliability chemical deterioration. Maintenance should field 14-pages 402

  15. Assessing Assessment: Evaluating Outcomes and Reliabilities of Grammar, Math, and Writing Skill Measures in an Introductory Journalism Course

    ERIC Educational Resources Information Center

    Farwell, Tricia M.; Alligood, Leon; Fitzgerald, Sharon; Blake, Ken

    2016-01-01

    This article introduces an objective grammar and math assessment and evaluates the assessment's outcome and reliability when fielded among eighty-one students in media writing courses. In addition, the article proposes a rubric for grading straight news leads and compares the rubric's reliability with the reliability of rating straight news leads…

  16. Refinement and initial validation of a multidimensional composite scale for use in assessing acute postoperative pain in cats.

    PubMed

    Brondani, Juliana Tabarelli; Luna, Stelio Pacca Loureiro; Padovani, Carlos Roberto

    2011-02-01

    To refine and test construct validity and reliability of a composite pain scale for use in assessing acute postoperative pain in cats undergoing ovariohysterectomy. 40 cats that underwent ovariohysterectomy in a previous study. In a previous randomized, double-blind, placebo-controlled study, a composite pain scale was developed to assess postoperative pain in cats that received a placebo or an analgesic (tramadol, vedaprofen, or tramadol-vedaprofen combination). In the present study, the scale was refined via item analysis (distribution frequency and occurrence), a nonparametric ANOVA, and item-to-total score correlation. Construct validity was assessed via factor analysis and known-groups discrimination, and reliability was measured by assessing internal consistency. Respiratory rate and respiratory pattern were rejected after item analysis. Factor analysis resulted in 5 dimensions (F1 [psychomotor change], posture, comfort, activity, mental status, and miscellaneous behaviors; F2 [protection of wound area], reaction to palpation of the surgical wound and palpation of the abdomen and flank; F3 [physiologic variables], systolic arterial blood pressure and appetite; F4 [vocal expression of pain], vocalization; and F5 [heart rate]). Internal consistency was excellent for the overall scale and for F1, F2, and F3; very good for F4; and unacceptable for F5. Except for heart rate, the identified factors and scale total score could be used to detect differences between the analgesic and placebo groups and differences among the analgesic treatments. Results provided initial evidence of construct validity and reliability of a multidimensional composite tool for use in assessing acute postoperative pain in cats undergoing ovariohysterectomy.

  17. Risk-adjusted hospital outcomes for children's surgery.

    PubMed

    Saito, Jacqueline M; Chen, Li Ern; Hall, Bruce L; Kraemer, Kari; Barnhart, Douglas C; Byrd, Claudia; Cohen, Mark E; Fei, Chunyuan; Heiss, Kurt F; Huffman, Kristopher; Ko, Clifford Y; Latus, Melissa; Meara, John G; Oldham, Keith T; Raval, Mehul V; Richards, Karen E; Shah, Rahul K; Sutton, Laura C; Vinocur, Charles D; Moss, R Lawrence

    2013-09-01

    BACKGROUND The American College of Surgeons National Surgical Quality Improvement Program-Pediatric was initiated in 2008 to drive quality improvement in children's surgery. Low mortality and morbidity in previous analyses limited differentiation of hospital performance. Participating institutions included children's units within general hospitals and free-standing children's hospitals. Cases selected by Current Procedural Terminology codes encompassed procedures within pediatric general, otolaryngologic, orthopedic, urologic, plastic, neurologic, thoracic, and gynecologic surgery. Trained personnel abstracted demographic, surgical profile, preoperative, intraoperative, and postoperative variables. Incorporating procedure-specific risk, hierarchical models for 30-day mortality and morbidities were developed with significant predictors identified by stepwise logistic regression. Reliability was estimated to assess the balance of information versus error within models. In 2011, 46 281 patients from 43 hospitals were accrued; 1467 codes were aggregated into 226 groupings. Overall mortality was 0.3%, composite morbidity 5.8%, and surgical site infection (SSI) 1.8%. Hierarchical models revealed outlier hospitals with above or below expected performance for composite morbidity in the entire cohort, pediatric abdominal subgroup, and spine subgroup; SSI in the entire cohort and pediatric abdominal subgroup; and urinary tract infection in the entire cohort. Based on reliability estimates, mortality discriminates performance poorly due to very low event rate; however, reliable model construction for composite morbidity and SSI that differentiate institutions is feasible. The National Surgical Quality Improvement Program-Pediatric expansion has yielded risk-adjusted models to differentiate hospital performance in composite and specific morbidities. However, mortality has low utility as a children's surgery performance indicator. Programmatic improvements have resulted in actionable data.

  18. Evaluating reliability of WSN with sleep/wake-up interfering nodes

    NASA Astrophysics Data System (ADS)

    Distefano, Salvatore

    2013-10-01

    A wireless sensor network (WSN) (singular and plural of acronyms are spelled the same) is a distributed system composed of autonomous sensor nodes wireless connected and randomly scattered into a geographical area to cooperatively monitor physical or environmental conditions. Adequate techniques and strategies are required to manage a WSN so that it works properly, observing specific quantities and metrics to evaluate the WSN operational conditions. Among them, one of the most important is the reliability. Considering a WSN as a system composed of sensor nodes the system reliability approach can be applied, thus expressing the WSN reliability in terms of its nodes' reliability. More specifically, since often standby power management policies are applied at node level and interferences among nodes may arise, a WSN can be considered as a dynamic system. In this article we therefore consider the WSN reliability evaluation problem from the dynamic system reliability perspective. Static-structural interactions are specified by the WSN topology. Sleep/wake-up standby policies and interferences due to wireless communications can be instead considered as dynamic aspects. Thus, in order to represent and to evaluate the WSN reliability, we use dynamic reliability block diagrams and Petri nets. The proposed technique allows to overcome the limits of Markov models when considering non-linear discharge processes, since they cannot adequately represent the aging processes. In order to demonstrate the effectiveness of the technique, we investigate some specific WSN network topologies, providing guidelines for their representation and evaluation.

  19. The accuracy of Internet search engines to predict diagnoses from symptoms can be assessed with a validated scoring system.

    PubMed

    Shenker, Bennett S

    2014-02-01

    To validate a scoring system that evaluates the ability of Internet search engines to correctly predict diagnoses when symptoms are used as search terms. We developed a five point scoring system to evaluate the diagnostic accuracy of Internet search engines. We identified twenty diagnoses common to a primary care setting to validate the scoring system. One investigator entered the symptoms for each diagnosis into three Internet search engines (Google, Bing, and Ask) and saved the first five webpages from each search. Other investigators reviewed the webpages and assigned a diagnostic accuracy score. They rescored a random sample of webpages two weeks later. To validate the five point scoring system, we calculated convergent validity and test-retest reliability using Kendall's W and Spearman's rho, respectively. We used the Kruskal-Wallis test to look for differences in accuracy scores for the three Internet search engines. A total of 600 webpages were reviewed. Kendall's W for the raters was 0.71 (p<0.0001). Spearman's rho for test-retest reliability was 0.72 (p<0.0001). There was no difference in scores based on Internet search engine. We found a significant difference in scores based on the webpage's order on the Internet search engine webpage (p=0.007). Pairwise comparisons revealed higher scores in the first webpages vs. the fourth (corr p=0.009) and fifth (corr p=0.017). However, this significance was lost when creating composite scores. The five point scoring system to assess diagnostic accuracy of Internet search engines is a valid and reliable instrument. The scoring system may be used in future Internet research. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. A Standardized Rubric for Evaluating Webquest Design: Reliability Analysis of ZUNAL Webquest Design Rubric

    ERIC Educational Resources Information Center

    Unal, Zafer; Bodur, Yasar; Unal, Aslihan

    2012-01-01

    Current literature provides many examples of rubrics that are used to evaluate the quality of web-quest designs. However, reliability of these rubrics has not yet been researched. This is the first study to fully characterize and assess the reliability of a webquest evaluation rubric. The ZUNAL rubric was created to utilize the strengths of the…

Top