Sample records for compression plate dcp

  1. Biomechanical comparison of straight DCP and helical plates for fixation of transverse and oblique bone fractures.

    PubMed

    Aksakal, Bunyamin; Gurger, Murat; Say, Yakup; Yilmaz, Erhan

    2014-01-01

    Biomechanical comparison of straight DCP and helical plates for fixation of transversal and oblique tibial bone fractures were analyzed and compared to each other by axial compression, bending and torsion tests. An in vitro osteosynthesis of transverse (TF) and oblique bone fracture (OF) fixations have been analysed on fresh sheep tibias by using the DCP and helical compression plates (HP). Statistically significant differences were found for both DCP and helical plate fixations under axial compression, bending and torsional loads. The strength of fixation systems was in favor of DC plating with exception of the TF-HP fixation group under compression loads and torsional moments. The transvers fracture (TF) stability was found to be higher than that found in oblique fracture (OF) fixed by helical plates (HP). However, under torsional testing, compared to conventional plating, the helical plate fixations provided a higher torsional resistance and strength. The maximum stiffness at axial compression loading and maximum torsional strength was achieved in torsional testing for the TF-HP fixations. From in vitro biomechanical analysis, fracture type and plate fixation system groups showed different responses under different loadings. Consequently, current biomechanical analyses may encourage the usage of helical HP fixations in near future during clinical practice for transverse bone fractures.

  2. Ultrasonometry evaluation of axial compression osteosinthesis. An experimental study

    PubMed Central

    Bezuti, Márcio Takey; Mandarano, Luiz Garcia; Barbieri, Giuliano; Mazzer, Nilton; Barbieri, Cláudio Henrique

    2013-01-01

    OBJECTIVE: To measure the ultrasound propagation velocity (UV) through a tibial transverse osteotomy in sheep, before and after the fixation with a DCP plate. MATERIAL AND METHODS: Ten assemblies of a DCP plate with the diaphyseal segment of tibiae, in which a transverse osteotomy was made, were used. Both coronal and sagittal transverse and the axial UV were measured, first with the intact bone assembled with the plate and then with the uncompressed and compressed osteotomy; statistical comparisons were made at the 1% (p<0.01) level of significance. RESULTS: Compared with the intact bone assembly, axial UV significantly decreased with the addition of the osteotomy and significantly increased with compression, presenting the same behavior for the other modalities, although not significantly. DISCUSSION AND CONCLUSION: In accordance with the literature data on the ultrasonometric evaluation of fracture healing, underwater UV measurement was able to demonstrate the efficiency of DCP plate fixation. The authors conclude that the method has a potential for clinical application in the postoperative follow-up of DCP plate osteosinthesis, with a capability to demonstrate when it becomes ineffective. Laboratory investigation. PMID:24453644

  3. Biomechanical assessment and 3D finite element analysis of the treatment of tibial fractures using minimally invasive percutaneous plates

    PubMed Central

    Hu, Xin-Jia; Wang, Hua

    2017-01-01

    The aim of the present study was to investigate the biomechanical effects of varying the length of a limited contact-dynamic compression plate (LC-DCP) and the number and position of screws on middle tibial fractures, and to provide biomechanical evidence regarding minimally invasive plate osteosynthesis (MIPO). For biomechanical testing, 60 tibias from cadavers (age at mortality, 20–40 years) were used to create middle and diagonal fracture models without defects. Tibias were randomly grouped and analyzed by biomechanic and three-dimensional (3D) finite element analysis. The differences among LC-DCPs of different lengths (6-, 10- and 14-hole) with 6 screws, 14-hole LC-DCPs with different numbers of screws (6, 10 and 14), and 14-hole LC-DCPs with 6 screws at different positions with regard to mechanical characteristics, including compressing, torsion and bending, were examined. The 6-hole LC-DCP had greater vertical compression strain compared with the 10- and 14-hole LC-DCPs (P<0.01), and the 14-hole LC-DCP had greater lateral strain than the 6- and 10-hole LC-DCPs (P<0.01). Furthermore, significant differences in torque were observed among the LC-DPs of different lengths (P<0.01). For 14-hole LC-DCPs with different numbers of screws, no significant differences in vertical strain, lateral strain or torque were detected (P>0.05). However, plates with 14 screws had greater vertical strain compared with those fixed with 6 or 10 screws (P<0.01). For 4-hole LC-DCPs with screws at different positions, vertical compression strain values were lowest for plates with screws at positions 1, 4, 7, 8, 11 and 14 (P<0.01). The lateral strain values and vertical strain values for plates with screws at positions 1, 3, 6, 9, 12 and 14 were significantly lower compared with those at the other positions (P<0.01), and torque values were also low. Thus, the 14-hole LC-DCP was the most stable against vertical compression, torsion and bending, and the 6-hole LC-DCP was the least stable. However, the use of 14 screws with a 14-hole LC-DCP provided less stability against bending than did 6 or 10 screws. Furthermore, fixation with distributed screws, in which some screws were close to the fracture line, provided good stability against compression and torsion, while fixation with screws at the ends of the LC-DCP provided poor stability against bending, compressing and torsion. PMID:28781632

  4. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware.

    PubMed

    Windolf, Markus; Klos, Kajetan; Wähnert, Dirk; van der Pol, Bas; Radtke, Roman; Schwieger, Karsten; Jakob, Roland P

    2010-05-21

    Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence") utilizing conventional (non-locked) implants in comparison to conventional LC-DCP (limited contact dynamic compression plate) and LCP (locking compression plate) stabilization, in a human cadaveric diaphyseal gap model. In eight pairs of human cadaveric femora, one femur per pair was randomly assigned to receive a Fence construct with either elevated or non-elevated plate, while the contralateral femur received either an LCP or LC-DCP instrumentation. Fracture gap motion and fatigue performance under cyclic loading was evaluated successively in axial compression and in torsion. Results were statistically compared in a pairwise setting. The elevated Fence constructs allowed significantly higher gap motion compared to the LCP instrumentations (axial compression: p

  5. In vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: prototype equine spoon plate versus axially positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion.

    PubMed

    Sod, Gary A; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S; Gill, Marjorie S

    2007-12-01

    To compare in vitro monotonic biomechanical properties of an equine spoon plate (ESP) with an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws (DCP-TLS) inserted in lag fashion for equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=18 pairs). For each forelimb pair, 1 PIP joint was stabilized with an ESP (8 hole, 4.5 mm) and 1 with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression with load applied under displacement control at a constant rate of 5 cm/s. Six construct pairs were tested for cyclic fatigue under axial compression with cyclic load (0-7.5 kN) applied at 6 Hz; cycles to failure were recorded. Six construct pairs were tested in single cycle to failure under torsional loading applied at a constant displacement rate (0.17 radians/s) until rotation of 0.87 radians occurred. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load for ESP fixation were significantly greater (for axial compression and torsion) than for DCP-TLS fixation. Mean (+/- SD) values for the ESP and DCP-TLS fixation techniques, respectively, in single cycle to failure under axial compression were: yield load 123.9 +/- 8.96 and 28.5 +/- 3.32 kN; stiffness, 13.11 +/- 0.242 and 2.60 +/- 0.17 kN/cm; and failure load, 144.4 +/- 13.6 and 31.4 +/- 3.8 kN. In single cycle to failure under torsion, mean (+/- SD) values for ESP and DCP-TLS, respectively, were: stiffness 2,022 +/- 26.2 and 107.9 +/- 11.1 N m/rad; and failure load: 256.4 +/- 39.2 and 87.1 +/- 11.5 N m. Mean cycles to failure in axial compression of ESP fixation (622,529 +/- 65,468) was significantly greater than DCP-TLS (95,418 +/- 11,037). ESP was superior to an axial 3-hole narrow DCP with 2 abaxial transarticular screws inserted in lag fashion in resisting static overload forces and cyclic fatigue. In vitro results support further evaluation of ESP for PIP joint arthrodesis in horses. Its specific design may provide increased stability without need for external coaptation support.

  6. Screw Loosening and Pelvic Canal Narrowing After Lateral Plating of Feline Ilial Fractures With Locking and Nonlocking Plates.

    PubMed

    Schmierer, Philipp A; Kircher, Patrick R; Hartnack, Sonja; Knell, Sebastian C

    2015-10-01

    To compare the frequency of complications, including screw loosening and pelvic canal narrowing, associated with dynamic compression plating, locking plating, and double locking plating of ilial fractures in cats. Historical cohort study. The radiographs and medical records of cats with pelvic fractures that were presented between 2004 and 2013 were reviewed. The cases were categorized based on the plate type and number as dynamic compression plate (DCP), single locking plate (LPS) and double locking plates (dLPS). The frequency of screw loosening was compared across categories using a Fisher's exact test. The change in pelvic alignment, described by the change in sacral index (postoperative sacral index-followup sacral index), was compared across plate categories using ANOVA. The frequency of screw loosening for DCP (5/10) was significantly higher than LPS (1/13) and dLPS (0/11) (P = .05, P = .012, respectively). There was no significant difference in the SI change across plate categories. The mean change in sacral index for DCP was -0.11 (95%CI -0.25 to 0.03), for LPS was 0.0007 (95%CI -0.07 to 0.08), and for dLPS was -0.01 (95%CI -0.04 to 0.02). None of the cats showed constipation postoperatively. Screw loosening occurred less often but the change in pelvic canal alignment was not significantly different in ilial fractures repaired with LPS or dLPS compared to ilial fractures repaired with DCP. Locking plating of ilial fractures in cats may offer advantages compared to nonlocking plating. © Copyright 2015 by The American College of Veterinary Surgeons.

  7. Outcome of Repair of Distal Radial and Ulnar Fractures in Dogs Weighing 4 kg or Less Using a 1.5-mm Locking Adaption Plate or 2.0-mm Limited Contact Dynamic Compression Plate.

    PubMed

    Nelson, Thomas A; Strom, Adam

    2017-11-01

    Objectives  Retrospective evaluation of repairing distal radial and ulnar fractures in small breed dogs with the Synthes 1.5-mm locking Adaption plate system and compare results in a similar group of patients repaired with the Synthes 2.0-mm limited contact-dynamic compression plate (LC-DCP). Methods  Electronic medical records from one specialty referral centre were reviewed from March 21, 2010, to October 9, 2015, for patients weighing less than or equal to 4 kg that had a distal one-third radial and ulnar fracture repaired with a Synthes 1.5-mm locking adaption plate or Synthes 2.0-mm LC-DCP. Further inclusion criteria included application of the plate to the cranial surface of the radius via open reduction and internal fixation. Results  Six 1.5-mm Adaption plates and 7 2.0-mm LC-DCPs were used to repair 13 distal radial and ulnar fractures in 12 dogs. There were three major complications in the 1.5-mm adaption plate group (one plate fracture, one screw pull-out and one fracture through a distal screw hole) and one major complication in the 2.0-mm LC-DCP group due to a re-fracture. All patients without a complication had good or excellent functional outcome. Clinical Significance  The authors recommend that the 1.5-mm Adaption plate be used only when a 2.0-mm LC-DCP would not allow for a minimum of two screws in the distal segment and at the discretion of the surgeon. Schattauer GmbH Stuttgart.

  8. Failure mode and bending moment of canine pancarpal arthrodesis constructs stabilized with two different implant systems.

    PubMed

    Wininger, Fred A; Kapatkin, Amy S; Radin, Alex; Shofer, Frances S; Smith, Gail K

    2007-12-01

    To compare failure mode and bending moment of a canine pancarpal arthrodesis construct using either a 2.7 mm/3.5 mm hybrid dynamic compression plate (HDCP) or a 3.5 mm dynamic compression plate (DCP). Paired in vitro biomechanical testing of canine pancarpal arthrodesis constructs stabilized with either a 2.7/3.5 HDCP or 3.5 DCP. Paired cadaveric canine antebrachii (n=5). Pancarpal arthrodesis constructs were loaded to failure (point of maximum load) in 4-point bending using a materials-testing machine. Using this point of failure, bending moments were calculated from system variables for each construct and the 2 plating systems compared using a paired t-test. To examine the relationship between metacarpal diameter and screw diameter failure loads, linear regression was used and Pearson' correlation coefficient was calculated. Significance was set at P<.05. HDCP failed at higher loads than DCP for 9 of 10 constructs. The absolute difference in failure rates between the 2 plates was 0.552+/-0.182 N m, P=.0144 (95% confidence interval: -0.58 to 1.68). This is an 8.1% mean difference in bending strength. There was a significant linear correlation r=0.74 (P-slope=.014) and 0.8 (P-slope=.006) between metacarpal diameter and failure loads for the HDCP and 3.5 DCP, respectively. There was a small but significant difference between bending moment at failure between 2.7/3.5 HDCP and 3.5 DCP constructs; however, the difference may not be clinically evident in all patients. The 2.7/3.5 HDCP has physical and mechanical properties making it a more desirable plate for pancarpal arthrodesis.

  9. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion.

    PubMed

    Sod, Gary A; Riggs, Laura M; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S

    2010-01-01

    To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP-TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3-TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=15 pairs). For each forelimb pair, 1 PIP joint was stabilized with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP-TLS fixation were significantly greater than those of the 3-TLS fixation. Mean cycles to failure in axial compression of the DCP-TLS fixation was significantly greater than that of the 3-TLS fixation. The DCP-TLS was superior to the 3-TLS in resisting the static overload forces and in resisting cyclic fatigue. The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.

  10. Biomechanical testing of locking and nonlocking plates in the canine scapula.

    PubMed

    Acquaviva, Anthony E; Miller, Emily I; Eisenmann, David J; Stone, Rick T; Kraus, Karl H

    2012-01-01

    Locking plates have been shown to offer improved fixation in fractures involving either osteoporotic bone or bone with lesser screw pullout strength, such as thin and flat bones. Fractures of the scapular body are one type of fracture where the screw pullout strength using conventional plate fixation may not be sufficient to overcome physiologic forces. The purpose of this study was to compare the pullout strengths of locking plates to conventional nonlocking plates in the canine scapula. A 2.7 mm string of pearls plate (SOP) and a 2.7 mm limited contact dynamic compression plate (LC-DCP) were applied with similar divergent screws to the supraspinatus fossa of the scapula. Forces perpendicular to the plates were applied and both the loads at failure and modes of failure were recorded. No differences were noted in loads at failure between the two plating systems. Although the modes of failure were not significantly different, the SOP constructs tended to fail more often by bone slicing and coring, whereas the LC-DCP constructs failed primarily by screw stripping. Neither of the plate systems used in this study demonstrated a distinct mechanical advantage. The application and limitations of locking plate systems in various clinical situations require further study.

  11. Biomechanical analysis of posteromedial tibial plateau split fracture fixation.

    PubMed

    Zeng, Zhi-Min; Luo, Cong-Feng; Putnis, Sven; Zeng, Bing-Fang

    2011-01-01

    The purpose of this study was to compare the biomechanical strength of four different fixation methods for a posteromedial tibial plateau split fracture. Twenty-eight tibial plateau fractures were simulated using right-sided synthetic tibiae models. Each fracture model was randomly instrumented with one of the four following constructs, anteroposterior lag-screws, an anteromedial limited contact dynamic compression plate (LC-DCP), a lateral locking plate, or a posterior T-shaped buttress plate. Vertical subsidence of the posteromedial fragment was measured from 500 N to 1500 N during biomechanical testing, the maximum load to failure was also determined. It was found that the posterior T-shaped buttress plate allowed the least subsidence of the posteromedial fragment and produced the highest mean failure load than each of the other three constructs (P=0.00). There was no statistical significant difference between using lag screws or an anteromedial LC-DCP construct for the vertical subsidence at a 1500 N load and the load to failure (P>0.05). This study showed that a posterior-based buttress technique is biomechanically the most stable in-vitro fixation method for posteromedial split tibial plateau fractures, with AP screws and anteromedial-based LC-DCP are not as stable for this type of fracture. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Expression of TGF-β in Fractures Fixed by Nitinol Swan-like Memory Compressive Connectors

    NASA Astrophysics Data System (ADS)

    Li, M.; Zhang, C. C.; Xu, S. G.; Fu, Q. G.

    2011-07-01

    In this article, the effect of internal fixation of a Nitinol swan-like memory compressive connector (SMC) on the temporal expression of transforming growth factor-β (TGF-β) at fracture sites is evaluated. Specimens were collected from 35 New Zealand rabbits modeled for bilateral humeral fracture fixed with either SMC or stainless dynamic compression plate (DCP). Five rabbits each were killed at day 1, 3, 7, 14, 21, 28, and 56. The local positive staining potency, positive area ratio, and positive index of TGF-β were measured using an immunohistochemistry approach (EnVision) in combination with a computerized image analysis system. TGF-β staining was seen in mesenchymal cells, osteoblasts, chondrocytes, and in the extracellular matrix of fractures fixed in both the SMC and the DCP samples without a significant difference in staining at both the early stages (days 1 and 3) and day 56. A higher TGF-β content was observed in the fractures fixed with SMC when compared to that of DCP from day 7 to 28. As a conclusion, TGF-β is highly expressed in fractures fixed with SMC during chondrogenesis stage and entochondrostosis stage. Finally, the mechanism of how SMC promoting synthesis and secretion of TGF-β in the process of fracture healing has been discussed.

  13. An in vitro biomechanical comparison of hydroxyapatite coated and uncoated ao cortical bone screws for a limited contact: dynamic compression plate fixation of osteotomized equine 3rd metacarpal bones.

    PubMed

    Durham, Myra E; Sod, Gary A; Riggs, Laura M; Mitchell, Colin F

    2015-02-01

    To compare the monotonic biomechanical properties of a broad 4.5 mm limited contact-dynamic compression plate (LC-DCP) fixation secured with hydroxyapatite (HA) coated cortical bone screws (HA-LC-DCP) versus uncoated cortical bone screws (AO-LC-DCP) to repair osteotomized equine 3rd metacarpal (MC3) bones. Experimental. Adult equine cadaveric MC3 bones (n = 12 pair). Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for: (1) 4 point bending single cycle to failure testing; (2) 4 point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. For the HA-LC-DCP-MC3 construct, an 8-hole broad LC-DCP (Synthes Ltd, Paoli, PA) was secured on the dorsal surface of each randomly selected MC3 bone with a combination of four 5.5 mm and four 4.5 mm HA-coated cortical screws. For the AO-LC-DCP-MC3 construct, an 8-hole 4.5 mm broad LC-DCP was secured on the dorsal surface of the contralateral MC3 bone with a combination of four 5.5 mm and four 4.5 mm uncoated cortical screws. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P < .05. Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4 point bending, single cycle to failure, of the HA-LC-DCP fixation were significantly greater than those of the AO-LC-DCP fixation. Mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, in single cycle to failure under 4 point bending were: yield load, 26.7 ± 2.15 and 16.3 ± 1.38 kN; yield bending moment, 527.4 ± 42.4 and 322.9 ± 27.2 N-m; composite rigidity, 5306 ± 399 and 3003 ± 300 N-m/rad; failure load, 40.6 ± 3.94 and 26.5 ± 2.52 kN; and failure bending moment, 801.9 ± 77.9 and 522.9 ± 52.2 N-m. Mean cycles to failure in 4 point bending of the HA-LC-DCP fixation (116,274 ± 13,211) was significantly greater than that of the AO-LC-DCP fixation 47,619 ± 6580. Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad HA-LC-DCP fixation compared with the AO-LC-DCP fixation. In single cycle to failure under torsion, mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, were: yield load, 101.3 ± 14.68 and 70.54 ± 10.20 N-m; composite rigidity, 437.9 ± 32.9 and 220.7 ± 17.6 N-m/rad; and failure load: 105.7 ± 15.5 and 75.28 ± 10.1 N-m. HA-LC-DCP was superior to AO-LC-DCP in resisting the static overload forces (palmarodorsal 4 point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4 point bending. © Copyright 2014 by The American College of Veterinary Surgeons.

  14. Suitability of DCPs with screw locking elements to allow sufficient interfragmentary motion to promote secondary bone healing of osteoporotic fractures.

    PubMed

    Cuadrado, A; Yánez, A; Carta, J A; Garcés, G

    2013-06-01

    This paper analyses the suitability of a system comprising a Dynamic Compression Plate (DCP) and Screw Locking Elements (SLEs) to allow sufficient interfragmentary motion to promote secondary bone healing in osteoporotic fractures. Four fixation systems were mounted on bone-simulating reinforced epoxy bars filled with solid rigid polyurethane foam. Group 1, used for comparison purposes, represents a system comprised of a Locking Compression Plate (LCP) and eight locking screws. Groups 2 and 3 represent a system comprised of a DCP plate with eight cortical screws and two SLEs placed on the screws furthest from (group 2) and nearest to (group 3) the fracture. Group 4 represents the system comprised of a DCP plate with SLEs placed on all eight cortical screws. Cyclic compression tests of up to 10,000 load cycles were performed in order to determine the parameters of interest, namely the stiffnesses and the interfragmentary motion of the various configurations under consideration. Tukey's multiple comparison test was used to analyse the existence or otherwise of significant differences between the means of the groups. At 10,000 cycles, interfragmentary motion at the far cortex for group 2 was 0.60±0.04 mm and for group 3 0.59±0.03 mm (there being no significant differences: p=0.995). The mean interfragmentary motion at the far cortex of the LCP construct was 70% less than that of the two groups with 2SLEs (there being significant differences: p=1.1×10(-8)). In the case of group 4 this figure was 45% less than in groups 2 and 3 (there being significant differences: p=5.6×10(-6)). At 10,000 cycles, interfragmentary motion at the near cortex for group 2 was 0.24±0.06 mm and for group 3 0.24±0.03 mm (there being no significant differences: p=1.000). The mean interfragmentary motion at the near cortex of the LCP construct was 70.8% less than that of the two groups with 2SLEs (there being significant differences: p=0.011). In the case of group 4 this figure was 66.7% less than in groups 2 and 3 (there being significant differences: p=0.016). The mean stiffness at 10,000 cycles was 960±110 N mm(-1) for group 2 and 969±53 N mm(-1) for group 3 (there being no significant differences: p=1.000). For group 1 (the LCP construct) the mean stiffness at 10,000 cycles was 3144±446 N mm(-1), 3.25 times higher than that of groups 2 and 3 (there being significant differences: p=0.00002), and 1.6 times higher than that of the DCP+8SLEs construct (1944±408 N mm(-1), there being significant differences: p=0.007). It is concluded that using the DCP+2SLEs construct sufficient interfragmentary motion is ensured to promote secondary bone healing. However, if too many SLEs are used the result may be, as with the LCP, an excessively rigid system for callus formation. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Plate versus intramedullary fixation of two-part and multifragmentary displaced midshaft clavicle fractures - a long-term analysis.

    PubMed

    Chan, Gareth; Korac, Zelimir; Miletic, Matija; Vidovic, Dinko; Phadnis, Joideep; Bakota, Bore

    2017-11-01

    Surgical fixation of displaced midshaft clavicle fractures is predominantly achieved with intramedullary (IM) or plate fixation. Both techniques have potential pitfalls: plate fixation involves greater periosteal stripping and protuberance of the implant, whereas IM fixation may be associated with implant-related complications, such as migration or skin irritation, which may lead to further surgery for implant removal. The aim of this study was to compare these two methods in simple (Robinson 2b.1) and multifragmentary (Robinson 2b.2) displaced midshaft clavicle fractures. A total of 133 consecutive patients who underwent surgical fixation for a displaced midshaft clavicle fracture with either IM fixation using a 2.5-mm Kirschner wire or plate fixation using an 8-hole Dynamic Compression Plate (DCP) were retrospectively reviewed. Follow-up was a minimum of 1 year. The patients were allocated into two injury groups: displaced simple 2-part fractures (64 IM vs. 16 DCP) and displaced multifragmentary fractures (27 IM vs. 26 DCP). The major observed outcome measures were: infection rate, non-union rate, reoperation rate and postoperative range of motion (ROM). Rates of non-union for displaced 2-part fractures were 2/64 (3.13%) with IM fixation and 0/16 (0.00%) with plate fixation (p = 0.477). For displaced multifragmentary fractures, rates of non-union were 2/27 (7.41%) with IM fixation and 0/26 (0.00%) with plate fixation (p = 0.161). No significant difference was observed between the two fixation modalities in patient-reported time to regain ROM on the injured side for displaced 2-part fractures (p = 0.129) and displaced multifragmentary fractures (p = 0.070). Deep infection rate was zero (p = 1.000) overall in the study, and reoperation rate for IM and plate fixation, respectively, was 3.13% and 6.25% in the Robinson 2b.1 group (p = 0.559) and 7.41% and 7.69% in the Robinson 2b.2 group (p = 0.969). IM fixation of displaced midshaft clavicle fractures (Robinson 2b.1) has an equivalent non-union rate to plate fixation and similarly low complication and reoperation rates. For displaced midshaft multifragmentary clavicle fractures (Robinson 2b.2), the higher non-union rates observed with IM fixation leads us to recommend consideration of plate fixation for Robinson 2b.2 fractures. © 2017 Elsevier Ltd. All rights reserved.

  16. Development of the Gliding Hole of the Dynamics Compression Plate

    NASA Astrophysics Data System (ADS)

    Salim, U. A.; Suyitno; Magetsari, R.; Mahardika, M.

    2017-02-01

    The gliding hole of the dynamics compression plate is designed to facilitate relative movement of pedicle screw during surgery application. The gliding hole shape is then geometrically complex. The gliding hole manufactured using machining processes used to employ ball-nose cutting tool. Then, production cost is expensive due to long production time. This study proposed to increase productivity of DCP products by introducing forming process (cold forming). The forming process used to involve any press tool devices. In the closed die forming press tool is designed with little allowance, then work-pieces is trapped in the mould after forming. Therefore, it is very important to determine hole geometry and dimensions of raw material in order to success on forming process. This study optimized the hole sizes with both geometry analytics and experiments. The success of the forming process was performed by increasing the holes size on the raw materials. The holes size need to be prepared is diameter of 5.5 mm with a length of 11.4 mm for the plate thickness 3 mm and diameter of 6 mm with a length of 12.5 mm for the plate thickness 4 mm.

  17. Effect of repeated compaction of tablets on tablet properties and work of compaction using an instrumented laboratory tablet press.

    PubMed

    Gamlen, Michael John Desmond; Martini, Luigi G; Al Obaidy, Kais G

    2015-01-01

    The repeated compaction of Avicel PH101, dicalcium phosphate dihydrate (DCP) powder, 50:50 DCP/Avicel PH101 and Starch 1500 was studied using an instrumented laboratory tablet press which measures upper punch force, punch displacement and ejection force and operates using a V-shaped compression profile. The measurement of work compaction was demonstrated, and the test materials were ranked in order of compaction behaviour Avicel PH101 > DCP/Avicel PH101 > Starch > DCP. The behaviour of the DCP/Avicel PH101 mixture was distinctly non-linear compared with the pure components. Repeated compaction and precompression had no effect on the tensile fracture strength of Avicel PH101 tablets, although small effects on friability and disintegration time were seen. Repeated compaction and precompression reduced the tensile strength and the increased disintegration time of the DCP tablets, but improved the strength and friability of Starch 1500 tablets. Based on the data reported, routine laboratory measurement of tablet work of compaction may have potential as a critical quality attribute of a powder blend for compression. The instrumented press was suitable for student use with minimal supervisor input.

  18. Role of autologous non-vascularised intramedullary fibular strut graft in humeral shaft nonunions following failed plating.

    PubMed

    Kashayi-Chowdojirao, Sreekanth; Vallurupalli, Aashish; Chilakamarri, Vijay Krishna; Patnala, Chandrasekhar; Chodavarapu, Lalith Mohan; Kancherla, Nageswara Rao; Khazi Syed, Asif Hussain

    2017-11-01

    Non-union humeral shaft fractures are seen frequently in clinical practice at about 2-10% in conservative management and 30% in surgically operated patients. Osteosynthesis using dynamic compression plate (DCP), intramedullary nailing, locking compression plate (LCP), Ilizarov technique along with bone grafting have been reported previously. In cases of prior failed plate-screw osteosynthesis the resultant osteopenia, cortical defect, bone loss, scalloping around screws and metallosis, make the management of non-union more complicated. Fibular graft as an intramedullary strut is useful in these conditions by increasing screw purchase, union and mechanical stability. This study is a retrospective and prospective follow up of revision plating along with autologous non-vascularised intramedullary fibular strut graft (ANVFG) for humeral non-unions following failed plate osteosynthesis. Seventy eight cases of nonunion humeral shaft fractures were managed in our institute between 2008 and 2015. Of these, 57 cases were failed plate osteosynthesis, in which 15 cases were infected and 42 cases were noninfected. Out of the 78 cases, bone grafting was done in 55 cases. Fibular strut graft was used in 22 patients, of which 4 cases were of primary nonunion with osteoporotic bone. Applying the exclusion criteria of infection and inclusion criteria of failed plate osteosynthesis managed with revision plating using either LCP or DCP and ANVFG, 17 cases were studied. The mean age of the patients was 40.11 yrs (range: 26-57 yrs). The mean duration of non-union was 4.43 yrs (range: 0.5-14 yrs). The mean follow-up period was 33.41 months (range: 12-94 months). The average length of fibula was 10.7 cm (range: 6-15 cm). Main outcome measurements included bony union by radiographic assessment and pre- and postoperative functional evaluation using the DASH (Disabilities of the Arm, Shoulder and Hand) score. Results: Sixteen out of 17 fractures united following revision plating and fibular strut grafting. Average time taken for union was 3.5 months (range: 3-5 months). Complications included one each of implant failure with bending, transient radial nerve palsy and transient ulnar nerve palsy. No case had infection, graft site morbidity or peroneal nerve palsy. Functional assessment by DASH score improved from 59.14 (range: 43.6-73.21) preoperatively to 23.39 (range: 8.03-34.2) postoperatively (p = 0.0003). Conclusion: The results of our study indicate that revision plating along with ANVFG is a reliable option in humeral diaphyseal non-unions with failed plate-screw osteosynthesis providing adequate screw purchase, mechanical stability and high chances of union with good functional outcome.

  19. Influence of the osteosynthesis plate on ultrasound propagation in the bone

    PubMed Central

    Bezuti, Márcio Takey; Mandarano-Filho, Luiz Garcia; Barbieri, Giuliano; Mazzer, Nilton; Barbieri, Cláudio Henrique

    2014-01-01

    Objective: To analyze the influence of steel plates for osteosynthesis on the velocity of ultrasound propagation (VU) through the bone. Methods: The transverse coronal and sagittal velocity of ultrasound propagation underwater were measured on the intact bone and then on assemblies of the same bone with two types of osteosynthesis plates (DCP and semi tubular), fixed onto the dorsal side of the bones. The first arriving signal (FAS) was the ultrasound parameter used, taking the coronal and sagittal diameters as the distances to calculate velocity. Intergroup statistical comparisons were made at significance level of 1% (p<0.01). Results: Velocity was higher on the intact bones than on the bone-plate assemblies and higher for the semitubular than for the compression plates, although differences were not statistically significant for most comparisons (p=0.0132 to 0.9884), indicating that the steel plates do not interfere significantly with ultrasound wave propagation through the bone-plate assemblies. Conclusion: The velocity reduction effect was attributed to the greater reflection coefficient of the steel as compared to that of bone and water. Ultrasonometry can, thus, be used in the evaluation of healing of fractures fixed with steel plates. Experimental Study. PMID:25328436

  20. Biomechanical analysis of four different fixations for the posterolateral shearing tibial plateau fracture.

    PubMed

    Zhang, Wei; Luo, Cong-Feng; Putnis, Sven; Sun, Hui; Zeng, Zhi-Min; Zeng, Bing-Fang

    2012-03-01

    The posterolateral shearing tibial plateau fracture is uncommon in the literature, however with the increased usage of computer tomography (CT), the incidence of these fractures is no longer as low as previously thought. Few studies have concentrated on this fracture, least of all using a biomechanical model. The purpose of this study was to compare and analyse the biomechanical characteristics of four different types of internal fixation to stabilise the posterolateral shearing tibial plateau fracture. Forty synthetic tibiae (Synbone, right) simulated the posterolateral shearing fracture models and these were randomly assigned into four groups; Group A was fixed with two anterolateral lag screws, Group B with an anteromedial Limited Contact Dynamic Compression Plate (LC-DCP), Group C with a lateral locking plate, and Group D with a posterolateral buttress plate. Vertical displacement of the posterolateral fragment was measured using three different strengths of axial loading force, and finally loaded until fixation failure. It was concluded that the posterolateral buttress plate is biomechanically the strongest fixation method for the posterolateral shearing tibial plateau fracture. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Shoulder arthrodesis for treatment of flail shoulder in children with polio.

    PubMed

    Miller, Joshua D; Pinero, Joseph R; Goldstein, Rachel; Yen, Yi-Meng; Eves, William; Otsuka, Norman Y

    2011-09-01

    Poliomyelitis in children can cause paralysis of shoulder girdle muscles leading to a flail shoulder. Shoulder arthrodesis is indicated as a possible treatment for these children in order to stabilize the shoulder. This retrospective study reviewed all shoulder arthrodesis surgeries owing to complications of polio performed at a major medical institution between 1981 and 1996 to assess position of fusion, radiographic evidence of fusion, complications, and patient satisfaction. A review of medical records identified 11 patients undergoing 13 shoulder arthrodesis procedures, with a mean age of 14.7 years at the time of the procedure. Internal fixation was achieved with large cancellous screws in 8 patients and a Dynamic Compression Plate (DCP) plate in 5 procedures. Average follow-up period was 41 months. Eight patients were placed into a spica cast and 5 used a sling postoperatively. Shoulder arthrodesis surgery in this cohort resulted in an average position of fusion with 42.3 degrees of abduction, 23.8 degrees of flexion, and 26.2 degrees of internal rotation. Twelve of the 13 procedures assessed for radiographic union demonstrated fusion. The most common complications were malrotation and nonunion. Of the 13 procedures, 2 underwent humeral osteotomies for malrotation, and 1 with 6.5 mm cancellous screws required revision with a DCP plate owing to nonunion. Six patients underwent hardware removal, 3 of which were specifically owing to complaints of painful hardware. At final follow-up, no patient reported pain and all expressed satisfaction with their results and improved shoulder function after repair. This study is the largest series of shoulder arthrodesis surgeries for treatment of patients with a flail shoulder from polio to date, providing a more thorough analysis of its efficacy as an indicated treatment. Level III-Retrospective Comparative Study.

  2. Retrospective analysis of factors associated with outcome of proximal interphalangeal joint arthrodesis in 82 horses including Warmblood and Thoroughbred sport horses and Quarter Horses (1992-2014).

    PubMed

    Herthel, T D; Rick, M C; Judy, C E; Cohen, N D; Herthel, D J

    2016-09-01

    Outcomes associated with arthrodesis of the proximal interphalangeal (PIP) joint in Quarter Horses used for Western performance activities are well documented but little is known regarding outcomes for other types of horses. To identify factors associated with outcomes, including breed and activity, after arthrodesis of the PIP joint in Warmbloods, Thoroughbreds and Quarter Horses. Retrospective case series. Surgical case records of 82 Quarter Horses principally engaged in Western performance and Thoroughbred or Warmblood breeds principally engaged in showing, showjumping and dressage, with arthrodesis of the PIP joint were reviewed. Arthrodesis was performed with either 3 transarticular cortex bone screws placed in lag fashion, a dynamic compression plate (DCP) with 2 transarticular cortex bone screws placed in lag fashion, or a locking compression plate (LCP) with 2 transarticular cortex bone screws placed in lag fashion. Demographic data, clinical presentation, radiographic findings, surgical technique, post operative treatment and complications were recorded. Long-term follow-up was obtained for all 82 horses. Osteoarthritis of the PIP joint was the most common presenting condition requiring arthrodesis, which was performed with either the 3 screw technique (n = 41), DCP fixation (n = 22), or LCP fixation (n = 19). Post operatively, 23/31 (74%) Warmbloods/Thoroughbreds and 44/51 (87%) Quarter Horses achieved successful outcomes. Thirteen of 23 (57%) Warmbloods/Thoroughbreds and 24 of 38 (63%) Quarter Horses, used for athletic performance, returned to successful competition. Within this subgroup of horses engaged in high-level activity, regardless of breed type, horses undergoing hindlimb arthrodesis were significantly more likely to return to successful competition (73%; 33/45) than those with forelimb arthrodesis (25%; 4/16, P = 0.002). Arthrodesis of the PIP joint in Warmbloods/Thoroughbreds and Quarter Horses results in a favourable outcome for return to their intended use and athletic competition. © 2015 EVJ Ltd.

  3. Investigation of drug-excipient compatibility using rheological and thermal tools

    NASA Astrophysics Data System (ADS)

    Trivedi, Maitri R.

    HYPOTHESIS: We plan to investigate a different approach to evaluate drug-excipient physical compatibility using rheological and thermal tools as opposed to commonly used chemical techniques in pharmaceutical industry. This approach offers practical solutions to routinely associated problems arising with API's and commonly used hydrates forms of excipients. ABSTRACT: Drug-Excipient compatibility studies are an important aspect of pre-formulation and formulation development in pharmaceutical research and development. Various approaches have been used in pharmaceutical industry including use of thermal analysis and quantitative assessment of drug-excipient mixtures after keeping the samples under stress environment depending upon the type of formulation. In an attempt to provide better understanding of such compatibility aspect of excipients with different properties of API, various rheological and thermal studies were conducted on binary mixtures of excipients which exist in different hydrates. Dibasic Calcium Phosphate (DCP, anhydrous and dihydrate forms) and Lactose (Lac, anhydrous and monohydrate) were selected with cohesive API's (Acetaminophen and Aspirin). Binary mixtures of DCP and Lac were prepared by addition of 0% w/w to 50% w/w of the API into each powder blend. Rheological and thermal aspects were considered using different approaches such as powder rheometer, rotational shear cell and traditional rheometery approaches like angle of repose (AOR), hausner's ratio (HR) and cares index (CI). Thermal analysis was conducted using modulated differential scanning calorimetry (MDSC) and thermal effusivity. The data suggested that the powder rheometer showed distinctive understanding in the flowability behavior of binary mixtures with addition of increasing proportion of API's than traditional approaches. Thermal approaches revealed the potential interaction of water of crystallization DCP-D with the API (APAP) while such interactions were absent in DCP-A, while in case of Lac-M and Lac-A, interaction with water of crystallization were not present. Binary mixtures prepared with DCP-D were better flowable while blends with DCP-A were better in stability (physical), compressibility and permeability. Similarly binary mixtures prepared with Lac-M were better flowable and stable in physical compatibility as compared to Lac-A. Lac-A were better in compressibility and permeability. Second part of these research included understanding the powder behavior from wet granulation point of view. Wet granulation includes the formation of agglomerates with powders to form granules in order to have better flowability, content uniformity and compressibility of granular mass. End point determination of powders involving change in powder energies and compressibility, permeability along with thermal analyses were conducted. The effects of water of crystallization on end point determination was studied and based on which overall effects on drug-excipient compatibility using different hydrate forms of excipients were evaluated.

  4. Evaluation of locked plate in the osteosynthesis of fractures in osteoporotic bones.

    PubMed

    Oboirien, Muhammad; Agbo, Stephen Patrick; Ajiboye, Lukman Olalekan

    2017-01-01

    The use of conventional dynamic compression plates (DCPs) in osteoporotic bones is associated with higher chances of implant failure. The advent and use of locking combi-plates have ensured a stable construct during osteosynthesis of fractures in osteoporotic bones. The study aims to assess the outcome of use of locking combi-plates in the management of fractures in osteoporotic bones in our environment. Cases of patients with nonunion and localized osteoporosis from January 2014 to December 2014 that were managed with locked combi-plates were reviewed. Outcome was assessed by time to healing, stability of implant construct after 6 and 12 months. There were 10 patients with mean age of 47.4 ± 12.63 years. There were 9 males and 1 female, and road traffic crashes were the mechanism of injury in 90% (n = 9) and gunshot injuries in 10% (n = 1). Atrophic nonunion was the most common indication for osteosynthesis with 80%, followed by fibrous nonunion with 10.0%. The humerus was the most common long bone involved with 50%. Locked broad DCP was used in 62.5%, and the duration between initial injury and surgery was 6 and 48 months, with an average of 17.5 months. The outcome was such that 90% healed after 12 months on follow-up while one case had the implant backing out and delay union at 6 months. The use of locked plate in the management of nonunion in the presence of osteoporosis ensures stable fixation construct and healing. Contexte: L'utilisation de plaques de compression dynamiques conventionnelles dans les os ostéoporotiques est associée à des chances plus élevées de défaillance de l'implant. L'avènement et l'utilisation de combi-plaques de verrouillage ont assuré une construction stable lors de l'ostéosyntheis de fractures dans les os ostéoporotiques. Objectifs: L'étude vise à évaluer le résultat de l'utilisation de combi-plaques de verrouillage dans la gestion des fractures dans les os ostéoporotiques dans notre environnement. Méthodologie: Les cas de patients atteints d'ostéoporose non syndiquée et localisée de janvier 2014 à décembre 2014 qui ont été gérés avec des combi-plaques verrouillées ont été examinés. Le résultat a été évalué par le temps de guérison, la stabilité de la construction d'implant après 6 et 12 mois. Résultats: il y avait 10 patients avec un âge moyen de 47,4 12,63. Il y avait 9 hommes et 1 accident de la route et de la route était le mécanisme de la blessure dans 90% (n = 9) et les blessures par balle dans 10% (n = 1). La non-union atrophique était l'indication la plus courante pour l'ostéosynthèse avec 80%, suivie d'une non-union fibreuse avec 10,0%. L'humérus était l'os le plus fréquent impliqué avec 50%. La plaque de compression dynamique bloquée (DCP) a été utilisée à 62,5% et la durée entre la blessure initiale et la chirurgie était de 6 et 48 mois avec une moyenne de 17,5 mois. Le résultat était tel que 90% ont été guéris après 12 mois de suivi, tandis que 1 cas avait l'implantation de l'implant et retardé l'union à 6 mois. L'utilisation de la plaque verrouillée dans la gestion de la non-union en présence d'ostéoporose assure une construction stable de fixation et une guérison.

  5. Comminuted supracondylar femoral fractures: a biomechanical analysis comparing the stability of medial versus lateral plating in axial loading.

    PubMed

    Briffa, Nikolai; Karthickeyan, Raju; Jacob, Joshua; Khaleel, Arshad

    2016-11-01

    The aim of this study was to compare the biomechanical properties of medial and lateral plating of a medially comminuted supracondylar femoral fracture. A supracondylar femoral fracture model comparing two fixation methods was tested cyclically in axial loading. One-centimetre supracondylar gap osteotomies were created in six synthetic femurs approximately 6 cm proximal to the knee joint. There were two constructs investigated: group 1 and group 2 were stabilized with an 8-hole LC-DCP, medially and laterally, respectively. Both construct groups were axially loaded. Global displacement (total length), wedge displacement, bending moment and strain were measured. Medial plating showed a significantly decreased displacement, bending moment and strain at the fracture site in axial loading. Medial plating of a comminuted supracondylar femur fracture is more stable than lateral plating.

  6. A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model.

    PubMed

    Kenzig, Allison R; Butler, James R; Priddy, Lauren B; Lacy, Kristen R; Elder, Steven H

    2017-07-13

    Fracture of the ilium is common orthopedic injury that often requires surgical stabilization in canine patients. Of the various methods of surgical stabilization available, application of a lateral bone plate to the ilium is the most common method of fixation. Many plating options are available, each having its own advantages and disadvantages. The purpose of this study was to evaluate the biomechanical properties of a 3.5 mm String-of-Pearls™ plate and a 3.5 mm dynamic compression plate in a cadaveric canine ilial fracture model. Hemipelves were tested in cantilever bending to failure and construct stiffness, yield load, displacement at yield, ultimate load, and mode of failure were compared. The mean stiffness of dynamic compression plate (116 ± 47 N/mm) and String-of-Pearls™ plate (107 ± 18 N/mm) constructs, mean yield load of dynamic compression plate (793 ± 333 N) and String-of-Pearls™ plate (860 ± 207 N) constructs, mean displacement at yield of dynamic compression plate (8.6 ± 3.0 mm) and String-of-Pearls™ plate (10.2 ± 2.8 mm) constructs, and ultimate load at failure of dynamic compression plate (936 ± 320 N) and String-of-Pearls™ plate (939 ± 191 N) constructs were not significantly different. No differences were found between constructs with respect to mode of failure. No significant biomechanical differences were found between String-of-Pearls™ plate and dynamic compression plate constructs in this simplified cadaveric canine ilial fracture model.

  7. Biomechanical comparison of straight and helical compression plates for fixation of transverse and oblique bone fractures: Modeling and experiments.

    PubMed

    Sezek, Sinan; Aksakal, Bunyamin; Gürger, Murat; Malkoc, Melih; Say, Y

    2016-08-12

    Total deformation and stability of straight and helical compression plates were studied by means of the finite element method (FEM) and in vitro biomechanical experiments. Fixations of transverse (TF) and oblique (45°) bone (OF) fractures have been analyzed on sheep tibias by designing the straight compression (SP) and Helical Compression Plate (HP) models. The effects of axial compression, bending and torsion loads on both plating systems were analyzed in terms of total displacements. Numerical models and experimental models suggested that under compression loadings, bone fracture gap closures for both fracture types were found to be in the favor of helical plate designs. The helical plate (HP) fixations provided maximum torsional resistance compared to the (SP) fixations. The fracture gap closure and stability of helical plate fixation for transverse fractures was determined to be higher than that found for the oblique fractures. The comparison of average compression stress, bending and torsion moments showed that the FEM and experimental results are in good agreement and such designs are likely to have a positive impact in future bone fracture fixation designs.

  8. Anomalous Buckling Characteristics of Laminated Metal-Matrix Composite Plates with Central Square Holes

    NASA Technical Reports Server (NTRS)

    Ko, William L.

    1998-01-01

    Compressive buckling analysis was performed on metal-matrix composite (MMC) plates with central square holes. The MMC plates have varying aspect ratios and hole sizes and are supported under different boundary conditions. The finite-element structural analysis method was used to study the effects of plate boundary conditions, plate aspect ratio, hole size, and the composite stacking sequence on the compressive buckling strengths of the perforated MMC plates. Studies show that by increasing the hole sizes, compressive buckling strengths of the perforated MMC plates could be considerably increased under certain boundary conditions and aspect ratios ("anomalous" buckling behavior); and that the plate buckling mode could be symmetrical or antisymmetrical, depending on the plate boundary conditions, aspect ratio, and the hole size. For same-sized plates with same-sized holes, the compressive buckling strengths of the perforated MMC plates with [90/0/0/90]2 lamination could be as much as 10 percent higher or lower than those of the [45/- 45/- 45/45]2 laminations, depending on the plate boundary conditions, plate aspect ratios, and the hole size. Clamping the plate edges induces far stronger "anomalous" buckling behavior (enhancing compressive buckling strengths at increasing hole sizes) of the perforated MMC plates than simply supporting the plate edges.

  9. Dynamic Stabilization of Simple Fractures With Active Plates Delivers Stronger Healing Than Conventional Compression Plating

    PubMed Central

    Tsai, Stanley; Bliven, Emily K.; von Rechenberg, Brigitte; Kindt, Philipp; Augat, Peter; Henschel, Julia; Fitzpatrick, Daniel C.; Madey, Steven M.

    2017-01-01

    Objectives: Active plates dynamize a fracture by elastic suspension of screw holes within the plate. We hypothesized that dynamic stabilization with active plates delivers stronger healing relative to standard compression plating. Methods: Twelve sheep were randomized to receive either a standard compression plate (CP) or an active plate (ACTIVE) for stabilization of an anatomically reduced tibial osteotomy. In the CP group, absolute stabilization was pursued by interfragmentary compression with 6 cortical screws. In the ACTIVE group, dynamic stabilization after bony apposition was achieved with 6 elastically suspended locking screws. Fracture healing was analyzed weekly on radiographs. After sacrifice 9 weeks postsurgery, the torsional strength of healed tibiae and contralateral tibiae was measured. Finally, computed tomography was used to assess fracture patterns and healing modes. Results: Healing in both groups included periosteal callus formation. ACTIVE specimens had almost 6 times more callus area by week 9 (P < 0.001) than CP specimens. ACTIVE specimens recovered on average 64% of their native strength by week 9, and were over twice as strong as CP specimens, which recovered 24% of their native strength (P = 0.008). Microcomputed tomography demonstrated that compression plating induced a combination of primary bone healing and gap healing. Active plating consistently stimulated biological bone healing by periosteal callus formation. Conclusions: Compared with compression plating, dynamic stabilization of simple fractures with active plates delivers significantly stronger healing. PMID:27861456

  10. Diaphyseal Fractures of the Forearm in Adults, Plating Or Intramedullary Nailing Is a Better Option for the Treatment?

    PubMed Central

    Al-Sadek, Tabet A.; Niklev, Desislav; Al-Sadek, Ahmed

    2016-01-01

    BACKGROUND: Fractures of the radius and ulna occupy a large field of the modern traumatology. Therefore, these fractures are a major subject in modern orthopaedics and traumatology. The study of the mechanisms of the trauma, and the pathophysiological changes that occur are of great importance for the development of ever more efficient and varied ways of the treatment and prophylactics of this type of fracture. AIM: The aim of this paper was to study the pattern of the diaphyseal fractures of the forearm in adults, to decide the modalities of surgical management, to observe the period of fracture healing clinically and radiologically, as well to study the rehabilitation of the patients. MATERIAL AND METHODS: The present study included 45 cases of diaphyseal fractures of both bones forearm in adults presenting to the orthopaedic outpatient department. For all the patients a detailed history was taken. A thorough clinical examination was carried out, required X-rays were taken, and initial treatment was given and admitted as in all patients. After careful pre-operative planning and evaluation for anaesthetic fitness, patients were operated for the fractures of both bone forearms. Twenty-three cases with 46 fractures were treated by open reduction and rigid fixation with DCP & Semi-tubular plates and 22 cases with 44 fractures were treated by closed reduction and fixation with “Talwarkar” intramedullary square nails. RESULTS: United results were found in 100% of plating group vs. 86% in the nailing group. Delayed and non-union results were found in 9% of the nailing group only. Average time to union in weeks was 9.4 weeks in the plating group vs. 10.2 weeks in the nailing group. CONCLUSION: Open reduction and internal fixation with compression plates with strict adherence to surgical technique is the gold standard method of treatment in both bones forearm fractures with excellent results than closed reduction, internal fixation with “Talwarkar” square nails which is also again a simple method with better results than conservative methods. PMID:28028411

  11. High voltage feedthrough bushing

    DOEpatents

    Brucker, John P.

    1993-01-01

    A feedthrough bushing for a high voltage diode provides for using compression sealing for all sealing surfaces. A diode assembly includes a central conductor extending through the bushing and a grading ring assembly circumferentially surrounding and coaxial with the central conductor. A flexible conductive plate extends between and compressively seals against the central conductor and the grading ring assembly, wherein the flexibility of the plate allows inner and outer portions of the plate to axially translate for compression sealing against the central conductor and the grading ring assembly, respectively. The inner portion of the plate is bolted to the central conductor for affecting sealing. A compression beam is also bolted to the central conductor and engages the outer portion of the plate to urge the outer portion toward the grading ring assembly to obtain compression sealing therebetween.

  12. A Study of the Efficiency of High-strength, Steel, Cellular-core Sandwich Plates in Compression

    NASA Technical Reports Server (NTRS)

    Johnson, Aldie E , Jr; Semonian, Joseph W

    1956-01-01

    Structural efficiency curves are presented for high-strength, stainless-steel, cellular-core sandwich plates of various proportions subjected to compressive end loads for temperatures of 80 F and 600 F. Optimum proportions of sandwich plates for any value of the compressive loading intensity can be determined from the curves. The efficiency of steel sandwich plates of optimum proportions is compared with the efficiency of solid plates of high-strength steel and aluminum and titanium alloys at the two temperatures.

  13. Compressive strength of damaged and repaired composite plates

    NASA Technical Reports Server (NTRS)

    Finn, Scott R.; He, Yi-Fei; Springer, George S.; Lee, Hung-Joo

    1992-01-01

    Tests were performed assessing the effectiveness of repair in restoring the mechanical properties of damaged, solid composite plates made either of Fiberite T300/976 graphite-epoxy, Fiberite IM7/977-2 graphite-toughened epoxy, or ICI APC-2 graphite-PEEK. The plate length, the layup and the amount of damage were also varied. Damage was introduced in the plates either by impacting them with a solid projectile or by applying a transverse static load. Some (75 percent) or all (100 percent) of the damaged zone was then cut out, and the plate was repaired by plugging and patching the hole. The effectiveness of the repair was evaluated by measuring the compressive strengths of undamaged plates, damaged plates with no cutout, damaged plates with a cutout, and repaired plates. The data at an intermediate stage of repair provide information on the effect of each repair step on the compressive strength. The results indicated that for the solid plates used in these tests, the repair methods used herein did not improve the compressive strength of already damaged plates.

  14. Ilizarov external fixation versus plate osteosynthesis in the management of extra-articular fractures of the distal tibia.

    PubMed

    Fadel, Mohamed; Ahmed, Mohamed Ali; Al-Dars, Ahmed Mounir; Maabed, Mustafa Ahmed; Shawki, Hashem

    2015-03-01

    The purpose of this study was to evaluate the outcome of Ilizarov external fixation (IE) versus dynamic compression plate (PO) in the management of extra-articular distal tibial fractures. Between 2010 and 2011, extra-articular distal tibial fractures in 40 consecutive patients met the inclusion criteria. They were classified according to AO classification fracture type A (A1, A2, and A3). In a randomized method, two equal groups were managed using either IE or PO. PO was performed using open reduction and internal fixation (ORIF) and DCP through anterolateral approach. IE was done using Ilizarov frame. For the PO group, non-weight bearing ambulation was permitted on the second postoperative day but partial weight bearing was permitted according to the progression in union criteria clinically and radiologically. For the IE group, weight bearing started as tolerated from the first postoperative day. Physiotherapy and pin-site care was performed by the patient themselves. Modified Mazur ankle score was applied to IE (excellent 10, good 10) and in PO (excellent 2, good 8, poor 6). Data were statically analysed using (Mann-Whitney test). The rate of healing in the IE group (average 130) was higher than the PO (average 196.5); plus, there were no cases of delayed union or nonunion in the IE group (p value 0.003). It was found that IE compared with PO provides provision of immediate weight bearing as tolerated following postoperative recovery, irrespective of radiological or clinical healing with no infection, deformity or non-union.

  15. The Synergy of Double Cross-linking Agents on the Properties of Styrene Butadiene Rubber Foams

    PubMed Central

    Shao, Liang; Ji, Zhan-You; Ma, Jian-Zhong; Xue, Chao-Hua; Ma, Zhong-Lei; Zhang, Jing

    2016-01-01

    Sulfur (S) cross-linking styrene butadiene rubber (SBR) foams show high shrinkage due to the cure reversion, leading to reduced yield and increased processing cost. In this paper, double cross-linking system by S and dicumyl peroxide (DCP) was used to decrease the shrinkage of SBR foams. Most importantly, the synergy of double cross-linking agents was reported for the first time to our knowledge. The cell size and its distribution of SBR foams were investigated by FESEM images, which show the effect of DCP content on the cell structure of the SBR foams. The relationships between shrinkage and crystalline of SBR foams were analyzed by the synergy of double cross-linking agents, which were demonstrated by FTIR, Raman spectra, XRD, DSC and TGA. When the DCP content was 0.6 phr, the SBR foams exhibit excellent physical and mechanical properties such as low density (0.223 g/cm3), reduced shrinkage (2.25%) and compression set (10.96%), as well as elevated elongation at break (1.78 × 103%) and tear strength (54.63 N/mm). The results show that these properties are related to the double cross-linking system of SBR foams. Moreover, the double cross-linking SBR foams present high electromagnetic interference (EMI) shielding properties compared with the S cross-linking SBR foams. PMID:27841307

  16. The Synergy of Double Cross-linking Agents on the Properties of Styrene Butadiene Rubber Foams

    NASA Astrophysics Data System (ADS)

    Shao, Liang; Ji, Zhan-You; Ma, Jian-Zhong; Xue, Chao-Hua; Ma, Zhong-Lei; Zhang, Jing

    2016-11-01

    Sulfur (S) cross-linking styrene butadiene rubber (SBR) foams show high shrinkage due to the cure reversion, leading to reduced yield and increased processing cost. In this paper, double cross-linking system by S and dicumyl peroxide (DCP) was used to decrease the shrinkage of SBR foams. Most importantly, the synergy of double cross-linking agents was reported for the first time to our knowledge. The cell size and its distribution of SBR foams were investigated by FESEM images, which show the effect of DCP content on the cell structure of the SBR foams. The relationships between shrinkage and crystalline of SBR foams were analyzed by the synergy of double cross-linking agents, which were demonstrated by FTIR, Raman spectra, XRD, DSC and TGA. When the DCP content was 0.6 phr, the SBR foams exhibit excellent physical and mechanical properties such as low density (0.223 g/cm3), reduced shrinkage (2.25%) and compression set (10.96%), as well as elevated elongation at break (1.78 × 103%) and tear strength (54.63 N/mm). The results show that these properties are related to the double cross-linking system of SBR foams. Moreover, the double cross-linking SBR foams present high electromagnetic interference (EMI) shielding properties compared with the S cross-linking SBR foams.

  17. Circulating dendritic cell precursors in chronic kidney disease: a cross-sectional study.

    PubMed

    Paul, Katharina; Kretzschmar, Daniel; Yilmaz, Atilla; Bärthlein, Barbara; Titze, Stephanie; Wolf, Gunter; Busch, Martin

    2013-12-10

    Dendritic cells (DC) are professional antigen-presenting cells in the immune system. They patrol the blood as circulating dendritic cell precursors (DCP). Decreased blood DCP count has been shown to be related to atherosclerotic plaque burden. Since chronic kidney disease (CKD) is associated with chronic inflammation and increased cardiovascular risk, the aim of our study was to investigate a potential effect of CKD on circulating DCP numbers especially in patients with a history of cardiovascular disease. The number of circulating myeloid (mDCP), plasmacytoid (pDCP), and total DCP (tDCP) was analysed by flow cytometry in 245 patients with CKD stage 3 (with and without known cardiovascular events) and 85 coronary healthy controls. In addition, data were compared with a historical group of 130 patients with known coronary artery disease (CAD). Compared to controls, patients with CKD 3 revealed a significant decrease in circulating mDCP (-29%), pDCP (-43%), and tDCP (-38%) (P < 0.001, respectively). Compared with CAD-patients, the decrease in circulating DCP in CKD was comparable or even more pronounced indicating a potential role for DCP in cardiovascular risk potentiation due to CKD. Based on previous findings in CAD, the marked decrease of DCP in CKD implicates a potential role for DCP as a mediator of cardiovascular disease. Whether DCP in CKD may act as new cardiovascular biomarkers needs to be established in future prospective trials.

  18. LagLoc - a new surgical technique for locking plate systems.

    PubMed

    Triana, Miguel; Gueorguiev, Boyko; Sommer, Christoph; Stoffel, Karl; Agarwal, Yash; Zderic, Ivan; Helfen, Tobias; Krieg, James C; Krause, Fabian; Knobe, Matthias; Richards, R Geoff; Lenz, Mark

    2018-06-19

    Treatment of oblique and spiral fractures remains challenging. The aim of this study was to introduce and investigate the new LagLoc technique for locked plating with generation of interfragmentary compression, combining the advantages of lag-screw and locking-head-screw techniques. Oblique fracture was simulated in artificial diaphyseal bones, assigned to three groups for plating with a 7-hole locking compression plate. Group I was plated with three locking screws in holes 1, 4 and 7. The central screw crossed the fracture line. In group II the central hole was occupied with a lag screw perpendicular to fracture line. Group III was instrumented applying the LagLoc technique as follows. Hole 4 was predrilled perpendicularly to the plate, followed by overdrilling of the near cortex and insertion of a locking screw whose head was covered by a holding sleeve to prevent temporarily the locking in the plate hole and generate interfragmentary compression. Subsequently, the screw head was released and locked in the plate hole. Holes 1 and 7 were occupied with locking screws. Interfragmentary compression in the fracture gap was measured using pressure sensors. All screws in the three groups were tightened with 4Nm torque. Interfragmentary compression in group I (167 ± 25N) was significantly lower in comparison to groups II (431 ± 21N) and III (379 ± 59N), p≤0.005. The difference in compression between groups II and III remained not significant (p = 0.999). The new LagLoc technique offers an alternative tool to generate interfragmentary compression with the application of locking plates by combining the biomechanical advantages of lag screw and locking screw fixations. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. Regional variations in growth plate chondrocyte deformation as predicted by three-dimensional multi-scale simulations.

    PubMed

    Gao, Jie; Roan, Esra; Williams, John L

    2015-01-01

    The physis, or growth plate, is a complex disc-shaped cartilage structure that is responsible for longitudinal bone growth. In this study, a multi-scale computational approach was undertaken to better understand how physiological loads are experienced by chondrocytes embedded inside chondrons when subjected to moderate strain under instantaneous compressive loading of the growth plate. Models of representative samples of compressed bone/growth-plate/bone from a 0.67 mm thick 4-month old bovine proximal tibial physis were subjected to a prescribed displacement equal to 20% of the growth plate thickness. At the macroscale level, the applied compressive deformation resulted in an overall compressive strain across the proliferative-hypertrophic zone of 17%. The microscale model predicted that chondrocytes sustained compressive height strains of 12% and 6% in the proliferative and hypertrophic zones, respectively, in the interior regions of the plate. This pattern was reversed within the outer 300 μm region at the free surface where cells were compressed by 10% in the proliferative and 26% in the hypertrophic zones, in agreement with experimental observations. This work provides a new approach to study growth plate behavior under compression and illustrates the need for combining computational and experimental methods to better understand the chondrocyte mechanics in the growth plate cartilage. While the current model is relevant to fast dynamic events, such as heel strike in walking, we believe this approach provides new insight into the mechanical factors that regulate bone growth at the cell level and provides a basis for developing models to help interpret experimental results at varying time scales.

  20. Regional Variations in Growth Plate Chondrocyte Deformation as Predicted By Three-Dimensional Multi-Scale Simulations

    PubMed Central

    Gao, Jie; Roan, Esra; Williams, John L.

    2015-01-01

    The physis, or growth plate, is a complex disc-shaped cartilage structure that is responsible for longitudinal bone growth. In this study, a multi-scale computational approach was undertaken to better understand how physiological loads are experienced by chondrocytes embedded inside chondrons when subjected to moderate strain under instantaneous compressive loading of the growth plate. Models of representative samples of compressed bone/growth-plate/bone from a 0.67 mm thick 4-month old bovine proximal tibial physis were subjected to a prescribed displacement equal to 20% of the growth plate thickness. At the macroscale level, the applied compressive deformation resulted in an overall compressive strain across the proliferative-hypertrophic zone of 17%. The microscale model predicted that chondrocytes sustained compressive height strains of 12% and 6% in the proliferative and hypertrophic zones, respectively, in the interior regions of the plate. This pattern was reversed within the outer 300 μm region at the free surface where cells were compressed by 10% in the proliferative and 26% in the hypertrophic zones, in agreement with experimental observations. This work provides a new approach to study growth plate behavior under compression and illustrates the need for combining computational and experimental methods to better understand the chondrocyte mechanics in the growth plate cartilage. While the current model is relevant to fast dynamic events, such as heel strike in walking, we believe this approach provides new insight into the mechanical factors that regulate bone growth at the cell level and provides a basis for developing models to help interpret experimental results at varying time scales. PMID:25885547

  1. MicroRNA-141-3p/200a-3p target and may be involved in post-transcriptional repression of RNA decapping enzyme Dcp2 during renal development.

    PubMed

    Zhang, Ming-Nan; Tang, Qun-Ye; Li, Rui-Min; Song, Man-Gen

    2018-06-18

    The RNA decapping enzyme Dcp2 is a crucial enzyme involved in the process of RNA turnover, which can post-transcriptionally regulate gene expression. Dcp2 has been found to be highly expressed in embryonic, but not adult, kidneys. Here we showed that Dcp2 mRNA was expressed, but Dcp2 proteins were absent, in mouse kidneys after postnatal day 10 (P10). In kidneys of adult Dcp2-IRES-EGFP knock-in mice, Dcp2 was undetectable but EGFP was expressed, indicating that Dcp2 mRNA was not completely silenced in adult kidneys. Using luciferase reporter assays, we found that miR-141-3p/200a-3p directly targeted the 3' UTR of Dcp2 mRNA. Overexpression of miR-141-3p and miR-200a-3p downregulated endogenous Dcp2 protein expression. Furthermore, miR-141-3p and miR-200a-3p expression was low in embryonic kidneys but increased dramatically after P10 and was negatively correlated with Dcp2 protein expression during renal development. These results suggest miR-141-3p/200a-3p may be involved in post-transcriptional repression of Dcp2 expression during renal development. IRES: internal ribosome entry site; EGFP: enhanced green fluorescent protein; UTR: untranslated region.

  2. Buckling and postbuckling behavior of square compression-loaded graphite-epoxy plates with circular cutouts

    NASA Technical Reports Server (NTRS)

    Nemeth, Michael P.

    1989-01-01

    The postbuckling behavior of square compression-loaded graphite-epoxy plates and isotropic plates with a central circular cutout is studied. The results suggest that the change in the plate's axial stiffness is strongly dependent on cutout size and plate orthotropy. It is found that the cutout size and stacking sequence of a composite plate may be tailored to optimize postbuckling stiffness. Also, it is suggested that a cutout may influence model interaction in a plate. The effects of load-path eccentricity on buckling behavior are examined.

  3. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    PubMed

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  4. DcpS is a transcript-specific modulator of RNA in mammalian cells

    PubMed Central

    Zhou, Mi; Bail, Sophie; Plasterer, Heather L.; Rusche, James

    2015-01-01

    The scavenger decapping enzyme DcpS is a multifunctional protein initially identified by its property to hydrolyze the resulting cap structure following 3′ end mRNA decay. In Saccharomyces cerevisiae, the DcpS homolog Dcs1 is an obligate cofactor for the 5′-3′ exoribonuclease Xrn1 while the Caenorhabditis elegans homolog Dcs-1, facilitates Xrn1 mediated microRNA turnover. In both cases, this function is independent of the decapping activity. Whether DcpS and its decapping activity can affect mRNA steady state or stability in mammalian cells remains unknown. We sought to determine DcpS target genes in mammalian cells using a cell-permeable DcpS inhibitor compound, RG3039 initially developed for therapeutic treatment of spinal muscular atrophy. Global mRNA levels were examined following DcpS decapping inhibition with RG3039. The steady-state levels of 222 RNAs were altered upon RG3039 treatment. Of a subset selected for validation, two transcripts that appear to be long noncoding RNAs HS370762 and BC011766, were dependent on DcpS and its scavenger decapping catalytic activity and referred to as DcpS-responsive noncoding transcripts (DRNT) 1 and 2, respectively. Interestingly, only the increase in DRNT1 transcript was accompanied with an increase of its RNA stability and this increase was dependent on both DcpS and Xrn1. Importantly, unlike in yeast where the DcpS homolog is an obligate cofactor for Xrn1, stability of additional Xrn1 dependent RNAs were not altered by a reduction in DcpS levels. Collectively, our data demonstrate that DcpS in conjunction with Xrn1 has the potential to regulate RNA stability in a transcript-selective manner in mammalian cells. PMID:26001796

  5. Deformation Response of Unsymmetrically Laminated Plates Subjected to Inplane Loading

    NASA Technical Reports Server (NTRS)

    Ochinero, Tomoya T.; Hyer, Michael W.

    2002-01-01

    This paper discusses the out-of-plane deformation behavior of unsymmetric cross-ply composite plates compressed inplane by displacing one edge of the plate a known amount. The plates are assumed to be initially flat and several boundary conditions are considered. Geometrically nonlinear behavior is assumed. The primary objectives are to study the out-of-plane behavior as a function of increasing inplane compression and to determine if bifurcation behavior and secondary buckling can occur. It is shown that, depending on the boundary conditions, both can occur, though the characteristics are different than the pre and post-buckling behavior of a companion symmetric cross-ply plate. Furthermore, while a symmetric cross-ply plate can postbuckle with either a positive or negative out-of-plane displacement, the unsymmetric cross-ply plates studied deflect out-of-plane only in one direction throughout the range of inplane compression, the direction again depending on the boundary conditions

  6. Metabolism of 2,4-dichlorophenol in tobacco engineered with bacterial degradative genes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perkins, E.J.; Sekine, M.; Gordon, M.P.

    1990-05-01

    The potential use of plants in toxic waste remediation has been overlooked. While chlorophenols are relatively slowly metabolized in Nicotiana tabacum var. Xanthi leaf extracts, chlorocatechols are rapidly metabolized, presumably by polyphenol oxidases. Our initial focus has been the fate of 2,4-dichlorophenol (2,4DCP) in var. Xanthi plants which express a bacterial 2,4DCP hydroxylase, which converts 2,4DCP to 3,5-dichlorocatechol. The roots of wild type and 2,4DCP hydroxylase transgenic plants growing in hydroponics were exposed to {sup 14}C-2,4DCP. Approximately 95% of {sup 14}C-2,4DCP metabolites remained in the roots when exposed to 2,4DCP. Upon extraction of root tissue, three major metabolites were foundmore » in untransformed plants and four major metabolites in transformed plants. Upon digestion with beta-D-glucosidase, these metabolites disappeared concomitant with the appearance of free 2,4DCP in wild type plants and 2,4DCP and 3,5-dichlorocatechol in transgenic plants. It is apparent that the chlorophenols are not readily available substrates for polyphenol oxidases in whole plants.« less

  7. Characterization of dipeptidylcarboxypeptidase of Leishmania donovani: a molecular model for structure based design of antileishmanials

    NASA Astrophysics Data System (ADS)

    Baig, Mirza Saqib; Kumar, Ashutosh; Siddiqi, Mohammad Imran; Goyal, Neena

    2010-01-01

    Leishmania donovani dipeptidylcarboxypeptidsae (LdDCP), an angiotensin converting enzyme (ACE) related metallopeptidase has been identified and characterized as a putative drug target for antileishmanial chemotherapy. The kinetic parameters for LdDCP with substrate, Hip-His-Leu were determined as, Km, 4 mM and Vmax, 1.173 μmole/ml/min. Inhibition studies revealed that known ACE inhibitors (captopril and bradykinin potentiating peptide; BPP1) were weak inhibitors for LdDCP as compared to human testicular ACE (htACE) with Ki values of 35.8 nM and 3.9 μM, respectively. Three dimensional model of LdDCP was generated based on crystal structure of Escherichia coli DCP (EcDCP) by means of comparative modeling and assessed using PROSAII, PROCHECK and WHATIF. Captopril docking with htACE, LdDCP and EcDCP and analysis of molecular electrostatic potentials (MEP) suggested that the active site domain of three enzymes has several minor but potentially important structural differences. These differences could be exploited for designing selective inhibitor of LdDCP thereby antileishmanial compounds either by denovo drug design or virtual screening of small molecule databases.

  8. Maternally Recruited DCP1A and DCP2 Contribute to Messenger RNA Degradation During Oocyte Maturation and Genome Activation in Mouse1

    PubMed Central

    Ma, Jun; Flemr, Matyas; Strnad, Hynek; Svoboda, Petr; Schultz, Richard M.

    2012-01-01

    ABSTRACT The oocyte-to-zygote transition entails transforming a highly differentiated oocyte into totipotent blastomeres and represents one of the earliest obstacles that must be successfully hurdled for continued development. Degradation of maternal mRNAs, which likely lies at the heart of this transition, is characterized by a transition from mRNA stability to instability during oocyte maturation. Although phosphorylation of the oocyte-specific RNA-binding protein MSY2 during maturation is implicated in making maternal mRNAs more susceptible to degradation, mechanisms underlying mRNA degradation during oocyte maturation remain poorly understood. We report that DCP1A and DCP2, proteins responsible for decapping mRNA, are encoded by maternal mRNAs recruited for translation during maturation via cytoplasmic polyadenylation elements located in their 3′ untranslated regions. Both DCP1A and DCP2 are phosphorylated during maturation, with CDC2A being the kinase likely responsible for both, although MAPK may be involved in DCP1A phosphorylation. Inhibiting accumulation of DCP1A and DCP2 by RNA interference or morpholinos decreases not only degradation of mRNAs during meiotic maturation but also transcription of the zygotic genome. The results indicate that maternally recruited DCP1A and DCP2 are critical players in the transition from mRNA stability to instability during meiotic maturation and that proper maternal mRNA degradation must be successful to execute the oocyte-to-zygote transition. PMID:23136299

  9. Regiospecific dechlorination of pentachlorophenol by dichlorophenol-adapted microorganisms in freshwater, anaerobic sediment slurries.

    PubMed Central

    Bryant, F O; Hale, D D; Rogers, J E

    1991-01-01

    The reductive dechlorination of pentachlorophenol (PCP) was investigated in anaerobic sediments that contained nonadapted or 2,4- or 3,4-dichlorophenol (DCP)-adapted microbial communities. Adaptation of sediment communities increased the rate of conversion of 2,4- or 3,4-DCP to monochlorophenols (CPs) and eliminated the lag phase before dechlorination was observed. Both 2,4- and 3,4-DCP-adapted sediment communities dechlorinated the six DCP isomers to CPs. The specificity of chlorine removal from the DCP isomers indicated a preference for ortho-chlorine removal by 2,4-DCP-adapted sediment communities and for para-chlorine removal by 3,4-DCP-adapted sediment communities. Sediment slurries containing nonadapted microbial communities either did not dechlorinate PCP or did so following a lag phase of at least 40 days. Sediment communities adapted to dechlorinate 2,4- or 3,4-DCP dechlorinated PCP without an initial lag phase. The 2,4-DCP-adapted communities initially removed the ortho-chlorine from PCP, whereas the 3,4-DCP-adapted communities initially removed the para-chlorine from PCP. A 1:1 mixture of the adapted sediment communities also dechlorinated PCP without a lag phase. Dechlorination by the mixture was regiospecific, following a para greater than ortho greater than meta order of chlorine removal. Intermediate products of degradation, 2,3,5,6-tetrachlorophenol, 2,3,5-trichlorophenol, 3,5-DCP, 3-CP, and phenol, were identified by a combination of cochromatography (high-pressure liquid chromatography) with standards and gas chromatography-mass spectrometry. PMID:1768102

  10. Compressed-air power tools in orthopaedic surgery: exhaust air is a potential source of contamination.

    PubMed

    Sagi, H C; DiPasquale, Thomas; Sanders, Roy; Herscovici, Dolfi

    2002-01-01

    To determine if the exhaust from surgical compressed-air power tools contains bacteria and if the exhaust leads to contamination of sterile surfaces. Bacteriologic study of orthopaedic power tools. Level I trauma center operative theater. None. Part I. Exhaust from two sterile compact air drills was sampled directly at the exhaust port. Part II. Exhaust from the drills was directed at sterile agar plates from varying distances. The agar plates represented sterile surfaces within the operative field. Part III. Control cultures. A battery-powered drill was operated over open agar plates in similar fashion as the compressed-air drills. Agar plates left open in the operative theater served as controls to rule out atmospheric contamination. Random cultures were taken from agar plates, gloves, drills, and hoses. Incidence of positive cultures. In Part I, all filters from both compressed-air drill exhausts were culture negative ( = 0.008). In Part II, the incidence of positive cultures for air drills number one and number two was 73% and 82%, respectively. The most commonly encountered organisms were, coagulase-negative Staphylococcus, and Micrococcus species. All control cultures from agar plates, battery-powered drill, gloves, and hoses were negative ( < 0.01). Exhaust from compressed-air power tools in orthopaedic surgery may contribute to the dissemination of bacteria onto the surgical field. We do not recommend the use of compressed-air power tools that do not have a contained exhaust.

  11. Simulated effect on the compressive and shear mechanical properties of bionic integrated honeycomb plates.

    PubMed

    He, Chenglin; Chen, Jinxiang; Wu, Zhishen; Xie, Juan; Zu, Qiao; Lu, Yun

    2015-05-01

    Honeycomb plates can be applied in many fields, including furniture manufacturing, mechanical engineering, civil engineering, transportation and aerospace. In the present study, we discuss the simulated effect on the mechanical properties of bionic integrated honeycomb plates by investigating the compressive and shear failure modes and the mechanical properties of trabeculae reinforced by long or short fibers. The results indicate that the simulated effect represents approximately 80% and 70% of the compressive and shear strengths, respectively. Compared with existing bionic samples, the mass-specific strength was significantly improved. Therefore, this integrated honeycomb technology remains the most effective method for the trial manufacturing of bionic integrated honeycomb plates. The simulated effect of the compressive rigidity is approximately 85%. The short-fiber trabeculae have an advantage over the long-fiber trabeculae in terms of shear rigidity, which provides new evidence for the application of integrated bionic honeycomb plates. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Finite element analysis of residual stress in cold expanded plate with different thickness and expansion ratio

    NASA Astrophysics Data System (ADS)

    Arifin Shariffudin, Kamarul; Karuppanan, Saravanan; Patil, Santosh S.

    2017-10-01

    Cold expansion of fastener/rivet holes is a common way to generate beneficial compressive residual stress around the fastener hole. In this study, cold expansion process was simulated by finite-element method in order to determine the residual stress field around two cold expanded holes by varying the plate thickness and expansion ratio of the hole. The model was developed in ANSYS and assigned to aluminium alloy 7475-T61 material model. The results showed that the residual stress become more compressive as the plate thickness is increased up to t/d = 2.6 and decreased for further level of thickness. In addition, the residual stress at the edge of the hole become more compressive as the expansion ratio is increased up to 4.5% and decreased for further level of expansion. This study also found that the residual stresses near the entrance and the exit face of the plate are less compressive than the residual stresses on the mid-thickness of the plate.

  13. 7-methylguanosine diphosphate (m(7)GDP) is not hydrolyzed but strongly bound by decapping scavenger (DcpS) enzymes and potently inhibits their activity.

    PubMed

    Wypijewska, Anna; Bojarska, Elzbieta; Lukaszewicz, Maciej; Stepinski, Janusz; Jemielity, Jacek; Davis, Richard E; Darzynkiewicz, Edward

    2012-10-09

    Decapping scavenger (DcpS) enzymes catalyze the cleavage of a residual cap structure following 3' → 5' mRNA decay. Some previous studies suggested that both m(7)GpppG and m(7)GDP were substrates for DcpS hydrolysis. Herein, we show that mononucleoside diphosphates, m(7)GDP (7-methylguanosine diphosphate) and m(3)(2,2,7)GDP (2,2,7-trimethylguanosine diphosphate), resulting from mRNA decapping by the Dcp1/2 complex in the 5' → 3' mRNA decay, are not degraded by recombinant DcpS proteins (human, nematode, and yeast). Furthermore, whereas mononucleoside diphosphates (m(7)GDP and m(3)(2,2,7)GDP) are not hydrolyzed by DcpS, mononucleoside triphosphates (m(7)GTP and m(3)(2,2,7)GTP) are, demonstrating the importance of a triphosphate chain for DcpS hydrolytic activity. m(7)GTP and m(3)(2,2,7)GTP are cleaved at a slower rate than their corresponding dinucleotides (m(7)GpppG and m(3)(2,2,7)GpppG, respectively), indicating an involvement of the second nucleoside for efficient DcpS-mediated digestion. Although DcpS enzymes cannot hydrolyze m(7)GDP, they have a high binding affinity for m(7)GDP and m(7)GDP potently inhibits DcpS hydrolysis of m(7)GpppG, suggesting that m(7)GDP may function as an efficient DcpS inhibitor. Our data have important implications for the regulatory role of m(7)GDP in mRNA metabolic pathways due to its possible interactions with different cap-binding proteins, such as DcpS or eIF4E.

  14. Optimization of a Simple Ship Structural Model Using MAESTRO

    DTIC Science & Technology

    1999-03-01

    Substructures MAESTRO Model Modules . . . MAESTRO Model Girders . . . . MAESTRO Model Tranverse Frames 9 10 11 12 13 Structural and Non-Structural...Weight Distribution 14 Longitudinal Load Distribution on the Model . 15 Tranverse Load Distribution on the Model . . . 16 Hogging Displacement of...Compression, Flange PYCP Panel Yield - Compression, Plate PSPBT Panel Serviceability- Plate Bending Tranverse PSPBL Panel Serviceability - Plate

  15. Fuel cell end plate structure

    DOEpatents

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.

  16. Effective Widths of Compression-Loaded Plates With a Cutout

    NASA Technical Reports Server (NTRS)

    Hilburger, Mark W.; Nemeth, Michael P.; Starnes, James H., Jr.

    2000-01-01

    A study of the effects of cutouts and laminate construction on the prebuckling and initial postbuckling stiffnesses, and the effective widths of compression-loaded, laminated-composite and aluminum square plates is presented. The effective-width concept is extended to plates with cutouts, and experimental and nonlinear finite-element analysis results are presented. Behavioral trends are compared for seven plate families and for cutout-diameter-to-plate-width ratios up to 0.66. A general compact design curve that can be used to present and compare the effective widths for a wide range of laminate constructions is also presented. A discussion of how the results can be used and extended to include certain types of damage, cracks, and other structural discontinuities or details is given. Several behavioral trends are described that initially appear to be nonintuitive. The results demonstrate a complex interaction between cutout size and plate orthotropy that affects the axial stiffness and effective width of a plate subjected to compression loads.

  17. Biomechanical analysis of fixation of middle third fractures of the clavicle.

    PubMed

    Drosdowech, Darren S; Manwell, Stuart E E; Ferreira, Louis M; Goel, Danny P; Faber, Kenneth J; Johnson, James A

    2011-01-01

    This biomechanical study compares four different techniques of fixation of middle third clavicular fractures. Twenty fresh-frozen clavicles were randomized into four groups. Each group used a different fixation device (3.5 Synthes reconstruction plate, 3.5 Synthes limited contact dynamic compression plate, 3.5 Synthes locking compression plate, and 4.5 DePuy Rockwood clavicular pin). All constructs were mechanically tested in bending and torque modes both with and without a simulated inferior cortical defect. Bending load to failure was also conducted. The four groups were compared using an analysis of variance test. The plate constructs were stiffer than the pin during both pure bending and torque loads with or without an inferior cortical defect. Bending load to failure with an inferior cortical defect revealed that the reconstruction plate was weaker compared with the other three groups. The limited contact and locking plates were stiffer than the reconstruction plate but demonstrated statistical significance only with the cortical defect. As hypothesized, the 3.5 limited contact dynamic compression plate and 3.5 locking compression plate demonstrated the greatest resistance to bending and torque loads, especially in the presence of simulated comminution of a middle third clavicular fracture. The reconstruction plate demonstrated lower stiffness and strength values compared with the other plates, especially with a cortical defect, whereas the pin showed poor resistance to bending and torque loads in all modes of testing. This information may help surgeons to choose the most appropriate method of fixation when treating fractures of the middle third of the clavicle.

  18. Progress in hypersonic turbulence modeling

    NASA Technical Reports Server (NTRS)

    Wilcox, David C.

    1991-01-01

    A compressibility modification is developed for k-omega (Wilcox, 1988) and k-epsilon (Jones and Launder, 1972) models, that is similar to those of Sarkar et al. (1989) and Zeman (1990). Results of the perturbation solution for the compressible wall layer demonstrate why the Sarkar and Zeman terms yield inaccurate skin friction for the flat-plate boundary layer. A new compressibility term is developed which permits accurate predictions of the compressible mixing layer, flat-plate boundary layer, and shock separated flows.

  19. Elastic and plastic buckling of simply supported solid-core sandwich plates in compression

    NASA Technical Reports Server (NTRS)

    Seide, Paul; Stowell, Elbridge Z

    1950-01-01

    A solution is presented for the problem of the compressive buckling of simply supported, flat, rectangular, solid-core sandwich plates stressed either in the elastic range or in the plastic range. Charts for the analysis of long sandwich plates are presented for plates having face materials of 24s-t3 aluminum alloy, 76s-t6 alclad aluminum alloy, and stainless steel. A comparison of computed and experimental buckling stresses of square solid-core sandwich plates indicates fair agreement between theory and experiment.

  20. Electrode Plate For An Eletrlchemical Cell And Having A Metal Foam Type Support, And A Method Of Obtaining Such An Electrode

    DOEpatents

    Verhoog, Roelof; Precigout, Claude; Stewart, Donald

    1996-05-21

    The electrode plate includes an active portion that is pasted with active material, and a plate head that is made up of three layers of compressed metal foam comprising: a non-pasted portion of height G of the support of the electrode plate; and two strips of non-pasted metal foam of height R on either side of the non-pasted portion of height G of the support and also extending for an overlap height h.sub.2 over the pasted portion of the support. The plate head includes a zone of reduced thickness including a portion that is maximally compressed, and a transitional portion between said maximally compressed portion and the remainder of the electrode which is of thickness e.sub.2. A portion of said plate head forms a connection tab. The method of obtaining the electrode consists in simultaneously rolling all three layers of metal foam in the plate head, and then in cutting matter away from the plates so as to obtain respective connection tabs.

  1. [Degradation of 2, 4-dichlorophenol in aqueous solution by ZVI/EDDS/air system].

    PubMed

    Sun, Qian; Zhou, Hai-Yan; Cao, Meng-Hua; Wu, Lin-Na; Wang, Lin-Ling; Chen, Jing; Lu, Xiao-Hua

    2012-11-01

    A new oxidation system of Fenton-like system (ZVI/EDDS/Air) has been developed to degrade 2,4-chlorophenols (2,4-DCP) in aqueous solution. The influences of initial conditions, i. e., EDDS concentration, iron dosage, aeration rate, 2,4-DCP concentration and pH as well as reaction temperature on the degradation of 2,4-DCP were studied. The results demonstrated that this ZVI/EDDS/Air system was able to effectively degrade 2,4-DCP in aqueous solution, and the degradation of 2,4-DCP conforms to the pseudo-first-order reaction kinetics equation. Removal of above 99% 2,4-DCP was achieved in ZVI/EDDS/Air system at room temperature and pressure after 1 h reaction when the initial conditions were 2,4-DCP 100 mg x L(-1), EDDS 0.80 mmo x L(-1), ZVI 20 g x L(-1), aeration rate 2 L x (min x L)(-1). Compared with ZVI/EDTA/Air system, ZVI/EDDS/Air system showed higher efficiency in the degradation of 2,4-DCP at ambient circumstance and was more environmentally benign.

  2. Fate and origin of 1,2-dichloropropane in an unconfined shallow aquifer

    USGS Publications Warehouse

    Tesoriero, A.J.; Loffler, F.E.; Liebscher, H.

    2001-01-01

    A shallow aquifer with different redox zones overlain by intensive agricultural activity was monitored for the occurrence of 1,2-dichloropropane (DCP) to assess the fate and origin of this pollutant. DCP was detected more frequently in groundwater samples collected in aerobic and nitrate-reducing zones than those collected from iron-reducing zones. Simulated DCP concentrations for groundwater entering an iron-reducing zone were calculated from a fate and transport model that included dispersion, sorption, and hydrolysis but not degradation. Simulated concentrations were well in excess of measured values, suggesting that microbial degradation occurred in the iron-reducing zone. Microcosm experiments were conducted using aquifer samples collected from iron-reducing and aerobic zones to evaluate the potential for microbial degradation of DCP and to explain field observations. Hydrogenolysis of DCP and production of monochlorinated propanes in microcosm experiments occurred only with aquifer materials collected from the iron-reducing zone, and no dechlorination was observed in microcosms established with aquifer materials collected from the aerobic zones. Careful analyses of the DCP/1,2,2-trichloropropane ratios in groundwater indicated that older fumigant formulations were responsible for the high levels of DCP present in this aquifer.A shallow aquifer with different redox zones overlain by intensive agricultural activity was monitored for the occurrence of 1,2-dichloropropane (DCP) to assess the fate and origin of this pollutant. DCP was detected more frequently in groundwater samples collected in aerobic and nitrate-reducing zones than those collected from iron-reducing zones. Simulated DCP concentrations for groundwater entering an iron-reducing zone were calculated from a fate and transport model that included dispersion, sorption, and hydrolysis but not degradation. Simulated concentrations were well in excess of measured values, suggesting that microbial degradation occurred in the iron-reducing zone. Microcosm experiments were conducted using aquifer samples collected from iron-reducing and aerobic zones to evaluate the potential for microbial degradation of DCP and to explain field observations. Hydrogenolysis of DCP and production of monochlorinated propanes in microcosm experiments occurred only with aquifer materials collected from the iron-reducing zone, and no dechlorination was observed in microcosms established with aquifer materials collected from the aerobic zones. Careful analyses of the DCP/1,2,2-trichloropropane ratios in groundwater indicated that older fumigant formulations were responsible for the high levels of DCP present in this aquifer.

  3. Effect of the Process Parameters on the Formability, Microstructure, and Mechanical Properties of Thin Plates Fabricated by Rheology Forging Process with Electromagnetic Stirring Method

    NASA Astrophysics Data System (ADS)

    Jin, Chul Kyu; Jang, Chang Hyun; Kang, Chung Gil

    2014-01-01

    A thin plate (150 × 150 × 1.2 mm) with embedded corrugation is fabricated using the rheoforming method. Semisolid slurry is created using the electromagnetic stirring (EMS) system, and the thin plate is made with the forging die at the 200-ton hydraulic press. The cross sections and microstructures of the slurry with and without stirring are examined. To investigate the effect of the process parameters on the formability, microstructure, and mechanical properties of thin plate the slurry is subjected to 16 types of condition for the forging experiment. The 16 types included the following conditions: Whether the EMS is applied or not, three fractions of the solid phase at 35, 45 and 55 pct; two compression velocities at 30 and 300 mm s-1; and four different compression pressures—100, 150, 200 and 250 MPa. The thin plate's formability is enhanced at higher punch velocity for compressing the slurry, and fine solid particles are uniformly distributed, which in turn, enhances the plate's mechanical properties. The pressure between 150 and 200 MPa is an appropriate condition to form thin plates. A thin plate without defects can be created when the slurry at 35 pct of the solid fraction (f s) was applied at the compression velocity of 300 mm s-1 and 150 MPa of pressure. The surface state of thin plate is excellent with 220 MPa of tensile strength and 13.5 pct of elongation. The primary particles are fine over the entire plate, and there are no liquid segregation-related defects.

  4. Compressive failure modes and parameter optimization of the trabecular structure of biomimetic fully integrated honeycomb plates.

    PubMed

    Chen, Jinxiang; Tuo, Wanyong; Zhang, Xiaoming; He, Chenglin; Xie, Juan; Liu, Chang

    2016-12-01

    To develop lightweight biomimetic composite structures, the compressive failure and mechanical properties of fully integrated honeycomb plates were investigated experimentally and through the finite element method. The results indicated that: fracturing of the fully integrated honeycomb plates primarily occurred in the core layer, including the sealing edge structure. The morphological failures can be classified into two types, namely dislocations and compactions, and were caused primarily by the stress concentrations at the interfaces between the core layer and the upper and lower laminations and secondarily by the disordered short-fiber distribution in the material; although the fully integrated honeycomb plates manufactured in this experiment were imperfect, their mass-specific compressive strength was superior to that of similar biomimetic samples. Therefore, the proposed bio-inspired structure possesses good overall mechanical properties, and a range of parameters, such as the diameter of the transition arc, was defined for enhancing the design of fully integrated honeycomb plates and improving their compressive mechanical properties. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Plastic buckling. [post-bifurcation and imperfection sensitivity

    NASA Technical Reports Server (NTRS)

    Hutchinson, J. W.

    1974-01-01

    The present article is concerned mainly with the post-bifurcation and imperfection-sensitivity aspects of plastic buckling. A simple two-degree-of-freedom model is used to introduce post-bifurcation behavior and a second model illustrates features of the behavior of continuous solids and structures. Hill's bifurcation criterion for a class of three-dimensional solids is applied to the Donnell-Mushtari-Vlasov (DMV) theory of plates and shells. A general treatment of the initial post-bifurcation behavior of plates and shells is given within the context of the DMV theory. This is illustrated by problems involving columns and circular plates under radial compression. Numerical results are given for a column under axial compression, a circular plate under radial compression, and spherical and cylindrical shells.

  6. Does plate type influence the clinical outcomes and implant removal in midclavicular fractures fixed with 2.7-mm anteroinferior plates? A retrospective cohort study

    PubMed Central

    2014-01-01

    Background The purpose of this study was to evaluate surgical healing rates, implant failure, implant removal, and the need for surgical revision with regards to plate type in midshaft clavicle fractures fixed with 2.7-mm anteroinferior plates utilizing modern plating techniques. Methods This retrospective exploratory cohort review took place at a level I teaching trauma center and a single large private practice office. A total of 155 skeletally mature individuals with 156 midshaft clavicle fractures between March 2002 and March 2012 were included in the final results. Fractures were identified by mechanism of injury and classified based on OTA/AO criteria. All fractures were fixed with 2.7-mm anteroinferior plates. Primary outcome measurements included implant failure, malunion, nonunion, and implant removal. Secondary outcome measurements included pain with the visual analog scale and range of motion. Statistically significant testing was set at 0.05, and testing was performed using chi-square, Fisher’s exact, Mann–Whitney U, and Kruskall-Wallis. Results Implant failure occurred more often in reconstruction plates as compared to dynamic compression plates (p = 0.029). Malunions and nonunions occurred more often in fractures fixed with reconstruction plates as compared to dynamic compression plates, but it was not statistically significant. Implant removal attributed to irritation or implant prominence was observed in 14 patients. Statistically significant levels of pain were seen in patients requiring implant removal (p = 0.001) but were not associated with the plate type. Conclusions Anteroinferior clavicular fracture fixation with 2.7-mm dynamic compression plates results in excellent healing rates with low removal rates in accordance with the published literature. Given higher rates of failure, 2.7-mm reconstruction plates should be discouraged in comparison to stiffer and more reliable 2.7-mm dynamic compression plates. PMID:24993508

  7. Analysis of behavior of simply supported flat plates compressed beyond the buckling load into the plastic range

    NASA Technical Reports Server (NTRS)

    Mayers, J; Budiansky, Bernard

    1955-01-01

    An analysis is presented of the postbuckling behavior of a simply supported square flat plate with straight edges compressed beyond the buckling load into the plastic range. The method of analysis involves the application of a variational principle of the deformation theory of plasticity in conjunction with computations carried out on a high-speed calculating machine. Numerical results are obtained for several plate proportions and for one material. The results indicate plate strengths greater than those that have been found experimentally on plates that do not satisfy straight-edge conditions. (author)

  8. Fenton-like oxidation of 2,4-DCP in aqueous solution using iron-based nanoparticles as the heterogeneous catalyst.

    PubMed

    Li, Renchao; Gao, Ying; Jin, Xiaoying; Chen, Zuliang; Megharaj, Mallavarapu; Naidu, Ravendra

    2015-01-15

    In this report, various iron-based nanoparticles (nZVI, n-Ni/Fe, n-Pd/Fe) were used for both heterogeneous Fenton oxidation of 2,4-dichlorophenol (2,4-DCP) and reductive dechlorination of 2,4-DCP in order to understand their roles in the Fenton oxidation and the reductive degradation of 2,4-DCP. The dechlorination efficiency of 2,4-DCP using nZVI, n-Ni/Fe, n-Fe/Pd and Fe(2)(+) was 6.48%, 6.80%, 15.95%, 5.02%, while Fenton oxidation efficiency of 2,4-DCP was 57.87%, 34.23%, 27.94%, 19.61% after 180 min, respectively. The new findings included a higher dechlorination using n-Fe/Pd due to Pd effective catalysis and the effective heterogeneous Fenton oxidation using nZVI depending on reductive dechlorination and heterogeneous Fenton oxidation occurs simultaneously. However, nZVI as the potential catalyst for heterogeneous Fenton was observed, and SEM, EDS and XRD demonstrate that change on the nZVI surface occurred due to the Fe(2+) leaching, and Total Organic Carbon (TOC) (30.71%) shows that 2,4-DCP was degraded. Furthermore, the experiment indicates that the pH values and concentration of 2,4-DCP significantly impacted on the heterogeneous Fenton oxidation of 2,4-DCP and the data fits well with the pseudo first-order kinetic model, which was a diffusion-controlled reaction. Finally, a possible mechanism for degradation of 2,4-DCP was proposed. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Physeal growth arrest by excessive compression: histological, biochemical, and micro-CT observations in rabbits.

    PubMed

    Yoo, Won Joon; Cheon, Jung-Eun; Lee, Hye Ran; Cho, Tae-Joon; Choi, In Ho

    2011-12-01

    Compressive force across the growth plate may cause retardation and even arrest of physeal growth. The purpose of this study was to investigate histologic changes, metabolic changes in terms of glycosaminoglycan (GAG) concentration, and contrast-enhanced micro-computed tomography (CEMCT) findings of physeal cartilage in a rabbit model of physeal damage caused by excessive compression. Compressive forces were applied via external fixators for two weeks to the growth plates of distal femurs and proximal tibiae of right hind-legs in 8-week-old rabbits. Left hind-legs remained intact and were used as controls. Forty-four bone specimens containing growth plates of distal femurs or proximal tibiae were harvested one week (n = 12) and four weeks (n = 32) after surgery, and examined for histologic findings (H&E staining) and GAGs quantification in physeal cartilage. After incubation in an ionic contrast material for 48 hours, specimens were scanned by CEMCT, and the pixel values of physeal cartilage were measured. CEMCT showed a thin, highly attenuated line parallel to the growth plate in compressed specimens harvested at four weeks after surgery, which was found to be transversely connected trabecular bone. In these specimens, GAG content in physeal cartilage was significantly lower, and CEMCT pixel values of physeal cartilage were significantly higher than in the specimens from the contralateral control side. Excessive compressive force applied to growth plates produces altered histologic features and metabolic function in terms of decreased GAG content in physeal cartilage, changes that can be demonstrated by CEMCT.

  10. Birnessite-induced mechanochemical degradation of 2,4-dichlorophenol.

    PubMed

    Nasser, A; Mingelgrin, U

    2014-07-01

    DCP (2,4-dichlorophenol) is the key-intermediate in the synthesis of some widely used pesticides and is an EPA priority pollutant. The mechanochemical breakdown of DCP loaded on birnessite (δ-MnO2), montmorillonite saturated with Na(+) or Cu(2+) and hematite was investigated. Mechanical force was applied by grinding of mixtures of DCP and the minerals, using mortar and pestle. Grinding of DCP for 5 min with the montmorillonites or with hematite resulted in negligible degradation during grinding, while grinding with birnessite induced the immediate degradation of 90% of the loaded DCP. Incubation for 24h after grinding did result in up to 30% degradation of the DCP loaded on the other minerals tested. HPLC and LC-MS analysis revealed that the transformation of DCP yielded oligomerization products as well as partial dechlorination. DCP degradation on birnessite was accompanied with a substantial increase in the extractability of manganese from the mineral into an acidic aqueous solution, indicating that Mn(IV) in the mineral transformed into Mn(II) and that birnessite served as an electron acceptor in the transformation. The oligomerization and partial dechlorination brought about by grinding, suggest a reduction in bioavailability and toxicity. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Linear optical pulse compression based on temporal zone plates.

    PubMed

    Li, Bo; Li, Ming; Lou, Shuqin; Azaña, José

    2013-07-15

    We propose and demonstrate time-domain equivalents of spatial zone plates, namely temporal zone plates, as alternatives to conventional time lenses. Both temporal intensity zone plates, based on intensity-only temporal modulation, and temporal phase zone plates, based on phase-only temporal modulation, are introduced and studied. Temporal zone plates do not exhibit the limiting tradeoff between temporal aperture and frequency bandwidth (temporal resolution) of conventional linear time lenses. As a result, these zone plates can be ideally designed to offer a time-bandwidth product (TBP) as large as desired, practically limited by the achievable temporal modulation bandwidth (limiting the temporal resolution) and the amount of dispersion needed in the target processing systems (limiting the temporal aperture). We numerically and experimentally demonstrate linear optical pulse compression by using temporal zone plates based on linear electro-optic temporal modulation followed by fiber-optics dispersion. In the pulse-compression experiment based on temporal phase zone plates, we achieve a resolution of ~25.5 ps over a temporal aperture of ~5.77 ns, representing an experimental TBP larger than 226 using a phase-modulation amplitude of only ~0.8π rad. We also numerically study the potential of these devices to achieve temporal imaging of optical waveforms and present a comparative analysis on the performance of different temporal intensity and phase zone plates.

  12. In vitro and in vivo effects of 2,4 diaminoquinazoline inhibitors of the decapping scavenger enzyme DcpS: Context-specific modulation of SMN transcript levels

    PubMed Central

    Androphy, Elliot J.; Calo, Alessandro; Potter, Kyle; Custer, Sara K.; Du, Sarah; Foley, Timothy L.; Gopalsamy, Ariamala; Reedich, Emily J.; Gordo, Susana M.; Gordon, William; Hosea, Natalie; Jones, Lyn H.; Krizay, Daniel K.; LaRosa, Gregory; Li, Hongxia; Mathur, Sachin; Menard, Carol A.; Patel, Paraj; Ramos-Zayas, Rebeca; Rietz, Anne; Rong, Haojing; Zhang, Baohong; Tones, Michael A.

    2017-01-01

    C5-substituted 2,4-diaminoquinazoline inhibitors of the decapping scavenger enzyme DcpS (DAQ-DcpSi) have been developed for the treatment of spinal muscular atrophy (SMA), which is caused by genetic deficiency in the Survival Motor Neuron (SMN) protein. These compounds are claimed to act as SMN2 transcriptional activators but data underlying that claim are equivocal. In addition it is unclear whether the claimed effects on SMN2 are a direct consequence of DcpS inhibitor or might be a consequence of lysosomotropism, which is known to be neuroprotective. DAQ-DcpSi effects were characterized in cells in vitro utilizing DcpS knockdown and 7-methyl analogues as probes for DcpS vs non-DcpS-mediated effects. We also performed analysis of Smn transcript levels, RNA-Seq analysis of the transcriptome and SMN protein in order to identify affected pathways underlying the therapeutic effect, and studied lysosomotropic and non-lysosomotropic DAQ-DCpSi effects in 2B/- SMA mice. Treatment of cells caused modest and transient SMN2 mRNA increases with either no change or a decrease in SMNΔ7 and no change in SMN1 transcripts or SMN protein. RNA-Seq analysis of DAQ-DcpSi-treated N2a cells revealed significant changes in expression (both up and down) of approximately 2,000 genes across a broad range of pathways. Treatment of 2B/- SMA mice with both lysomotropic and non-lysosomotropic DAQ-DcpSi compounds had similar effects on disease phenotype indicating that the therapeutic mechanism of action is not a consequence of lysosomotropism. In striking contrast to the findings in vitro, Smn transcripts were robustly changed in tissues but there was no increase in SMN protein levels in spinal cord. We conclude that DAQ-DcpSi have reproducible benefit in SMA mice and a broad spectrum of biological effects in vitro and in vivo, but these are complex, context specific, and not the result of simple SMN2 transcriptional activation. PMID:28945765

  13. Dorsal Plating of Unstable Scaphoid Fractures and Nonunions.

    PubMed

    Bain, Gregory I; Turow, Arthur; Phadnis, Joideep

    2015-09-01

    Achieving stable fixation of displaced acute and chronic nonunited scaphoid fractures continues to be a challenge for the treating surgeon. The threaded compression screw has been the mainstay of treatment of these fractures for the last 3 decades; however, persistent nonunion after screw fixation has prompted development of new techniques. Recent results of volar buttress plating have been promising. We describe a novel technique of dorsal scaphoid plating. In contrast to volar plating, the dorsal plate is biomechanically more favorable as it utilizes the tension side of the scaphoid bone for dynamic compression. Dorsal scaphoid plating provides a more stable construct than the traditional Herbert screw and mitigates the need for vascular or corticocancellous bone grafting in most cases.

  14. “Rational” Management of Dichlorophenols Biodegradation by the Microalga Scenedesmus obliquus

    PubMed Central

    Papazi, Aikaterini; Kotzabasis, Kiriakos

    2013-01-01

    The microalga Scenedesmus obliquus exhibited the ability to biodegrade dichlorophenols (dcps) under specific autotrophic and mixotrophic conditions. According to their biodegradability, the dichlorophenols used can be separated into three distinct groups. Group I (2,4-dcp and 2,6 dcp – no meta-substitution) consisted of quite easily degraded dichlorophenols, since both chloride substituents are in less energetically demanding positions. Group II (2,3-dcp, 2,5-dcp and 3,4-dcp – one meta-chloride) was less susceptible to biodegradation, since one of the two substituents, the meta one, required higher energy for C-Cl-bond cleavage. Group III (3,5-dcp – two meta-chlorides) could not be biodegraded, since both chlorides possessed the most energy demanding positions. In general, when the dcp-toxicity exceeded a certain threshold, the microalga increased the energy offered for biodegradation and decreased the energy invested for biomass production. As a result, the biodegradation per cell volume of group II (higher toxicity) was higher, than group I (lower toxicity) and the biodegradation of dichlorophenols (higher toxicity) was higher than the corresponding monochlorophenols (lower toxicity). The participation of the photosynthetic apparatus and the respiratory mechanism of microalga to biodegrade the group I and the group II, highlighted different bioenergetic strategies for optimal management of the balance between dcp-toxicity, dcp-biodegradability and culture growth. Additionally, we took into consideration the possibility that the intermediates of each dcp-biodegradation pathway could influence differently the whole biodegradation procedures. For this reason, we tested all possible combinations of phenolic intermediates to check cometabolic interactions. The present contribution bring out the possibility of microalgae to operate as “smart” bioenergetic “machines”, that have the ability to continuously “calculate” the energy reserves and “use” the most energetically advantageous dcp-biodegradation strategy. We tried to manipulate the above fact, changing the energy reserves and as a result the chosen strategy, in order to take advantage of their abilities in detoxifying the environment. PMID:23613903

  15. A genetic screen for modifiers of Drosophila caspase Dcp-1 reveals caspase involvement in autophagy and novel caspase-related genes.

    PubMed

    Kim, Young-Il; Ryu, Taewoo; Lee, Judong; Heo, Young-Shin; Ahnn, Joohong; Lee, Seung-Jae; Yoo, OokJoon

    2010-01-25

    Caspases are cysteine proteases with essential functions in the apoptotic pathway; their proteolytic activity toward various substrates is associated with the morphological changes of cells. Recent reports have described non-apoptotic functions of caspases, including autophagy. In this report, we searched for novel modifiers of the phenotype of Dcp-1 gain-of-function (GF) animals by screening promoter element- inserted Drosophila melanogaster lines (EP lines). We screened approximately 15,000 EP lines and identified 72 Dcp-1-interacting genes that were classified into 10 groups based on their functions and pathways: 4 apoptosis signaling genes, 10 autophagy genes, 5 insulin/IGF and TOR signaling pathway genes, 6 MAP kinase and JNK signaling pathway genes, 4 ecdysone signaling genes, 6 ubiquitination genes, 11 various developmental signaling genes, 12 transcription factors, 3 translation factors, and 11 other unclassified genes including 5 functionally undefined genes. Among them, insulin/IGF and TOR signaling pathway, MAP kinase and JNK signaling pathway, and ecdysone signaling are known to be involved in autophagy. Together with the identification of autophagy genes, the results of our screen suggest that autophagy counteracts Dcp-1-induced apoptosis. Consistent with this idea, we show that expression of eGFP-Atg5 rescued the eye phenotype caused by Dcp-1 GF. Paradoxically, we found that over-expression of full-length Dcp-1 induced autophagy, as Atg8b-GFP, an indicator of autophagy, was increased in the eye imaginal discs and in the S2 cell line. Taken together, these data suggest that autophagy suppresses Dcp-1-mediated apoptotic cell death, whereas Dcp-1 positively regulates autophagy, possibly through feedback regulation. We identified a number of Dcp-1 modifiers that genetically interact with Dcp-1-induced cell death. Our results showing that Dcp-1 and autophagy-related genes influence each other will aid future investigations of the complicated relationships between apoptosis and autophagy.

  16. "Rational" management of dichlorophenols biodegradation by the microalga Scenedesmus obliquus.

    PubMed

    Papazi, Aikaterini; Kotzabasis, Kiriakos

    2013-01-01

    The microalga Scenedesmus obliquus exhibited the ability to biodegrade dichlorophenols (dcps) under specific autotrophic and mixotrophic conditions. According to their biodegradability, the dichlorophenols used can be separated into three distinct groups. Group I (2,4-dcp and 2,6 dcp - no meta-substitution) consisted of quite easily degraded dichlorophenols, since both chloride substituents are in less energetically demanding positions. Group II (2,3-dcp, 2,5-dcp and 3,4-dcp - one meta-chloride) was less susceptible to biodegradation, since one of the two substituents, the meta one, required higher energy for C-Cl-bond cleavage. Group III (3,5-dcp - two meta-chlorides) could not be biodegraded, since both chlorides possessed the most energy demanding positions. In general, when the dcp-toxicity exceeded a certain threshold, the microalga increased the energy offered for biodegradation and decreased the energy invested for biomass production. As a result, the biodegradation per cell volume of group II (higher toxicity) was higher, than group I (lower toxicity) and the biodegradation of dichlorophenols (higher toxicity) was higher than the corresponding monochlorophenols (lower toxicity). The participation of the photosynthetic apparatus and the respiratory mechanism of microalga to biodegrade the group I and the group II, highlighted different bioenergetic strategies for optimal management of the balance between dcp-toxicity, dcp-biodegradability and culture growth. Additionally, we took into consideration the possibility that the intermediates of each dcp-biodegradation pathway could influence differently the whole biodegradation procedures. For this reason, we tested all possible combinations of phenolic intermediates to check cometabolic interactions. The present contribution bring out the possibility of microalgae to operate as "smart" bioenergetic "machines", that have the ability to continuously "calculate" the energy reserves and "use" the most energetically advantageous dcp-biodegradation strategy. We tried to manipulate the above fact, changing the energy reserves and as a result the chosen strategy, in order to take advantage of their abilities in detoxifying the environment.

  17. Failure mechanisms of uni-ply composite plates with a circular hole under static compressive loading

    NASA Technical Reports Server (NTRS)

    Khamseh, A. R.; Waas, A. M.

    1992-01-01

    The objective of the study was to identify and study the failure mechanisms associated with compressive-loaded uniply graphite/epoxy square plates with a central circular hole. It is found that the type of compressive failure depends on the hole size. For large holes with the diameter/width ratio exceeding 0.062, fiber buckling/kinking initiated at the hole is found to be the dominant failure mechanism. In plates with smaller hole sizes, failure initiates away from the hole edge or complete global failure occurs. Critical buckle wavelengths at failure are presented as a function of the normalized hole diameter.

  18. Analytical results for post-buckling behaviour of plates in compression and in shear

    NASA Technical Reports Server (NTRS)

    Stein, M.

    1985-01-01

    The postbuckling behavior of long rectangular isotropic and orthotropic plates is determined. By assuming trigonometric functions in one direction, the nonlinear partial differential equations of von Karman large deflection plate theory are converted into nonlinear ordinary differential equations. The ordinary differential equations are solved numerically using an available boundary value problem solver which makes use of Newton's method. Results for longitudinal compression show different postbuckling behavior between isotropic and orthotropic plates. Results for shear show that change in inplane edge constraints can cause large change in postbuckling stiffness.

  19. [Impact of disabling chronic pain: results of a cross-sectional population study with face-to-face interview].

    PubMed

    Cabrera-Leon, Andrés; Cantero-Braojos, Miguel Ángel

    2017-11-16

    To assess the impact of disabling chronic pain (DCP) on quality of life, work, consumption of medication and usage of health services. Cross-sectional population study with face-to-face interview. Andalusian Health Survey (2011 edition). 6,507 people over the age of 16 (p=q=0.5; confidence level=95%; sampling error=1.49, design effect=1.52). Not applicable. Dependent variable: DCP: population limited in their activity by any of the CP specified in the survey. quality of life, absence from work, consumption of medication and utilization of health services. Compared to a population without CP, DCP impact is 6 points less on the mental quality of life and 12 points on the physical one, medication consumption is triple, health services utilization is almost double, and long absence from work is triple. On the other hand, a population with nondisabling chronic pain (nDCP) presents similar results to a population without CP. We have considered DCP as another CP category because of its huge impact, as is shown in our study, on the study variables. On the contrary, the population with nDCP does not obtain significant impact differences when compared to the population without CP. Therefore, we believe that Primary Care and Public Health should lead different prevention strategies for DCP as well as for the identification of the nDCP population to decrease its possible deterioration towards DCP. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  20. The effect of a microscale fracture on dynamic capillary pressure of two-phase flow in porous media

    NASA Astrophysics Data System (ADS)

    Tang, Mingming; Lu, Shuangfang; Zhan, Hongbin; Wenqjie, Guo; Ma, Huifang

    2018-03-01

    Dynamic capillary pressure (DCP) effects, which is vital for predicting multiphase flow behavior in porous media, refers to the injection rate dependence capillary pressure observed during non-equilibrium displacement experiments. However, a clear picture of the effects of microscale fractures on DCP remains elusive. This study quantified the effects of microscale fractures on DCP and simulated pore-scale force and saturation change in fractured porous media using the multiphase lattice Boltzmann method (LBM). Eighteen simulation cases were carried out to calculate DCP as a function of wetting phase saturation. The effects of viscosity ratio and fracture orientation, aperture and length on DCP and DCP coefficient τ were investigated, where τ refers to the ratio of the difference of DCP and static capillary pressure (SCP) over the rate of wetting-phase saturation change versus time. Significant differences in τ values were observed between unfractured and fractured porous media. The τ values of fractured porous media were 1.1  × 104 Pa ms to 5.68 × 105 Pa ms, which were one or two orders of magnitude lower than those of unfractured porous media with a value of 4 × 106 Pa. ms. A horizontal fracture had greater effects on DCP and τ than a vertical fracture, given the same fracture aperture and length. This study suggested that a microscale fracture might result in large magnitude changes in DCP for two-phase flow.

  1. Passive margins getting squeezed in the mantle convection vice

    NASA Astrophysics Data System (ADS)

    Husson, Laurent; Yamato, Philippe; Becker, Thorsten; Pedoja, Kevin

    2013-04-01

    Quaternary coastal geomorphology reveals that passive margins underwent wholesale uplift at least during the glacial cycle. In addition, these not-so-passive margins often exhibit long term exhumation and tectonic inversion, which suggest that compression and tectonic shortening could be the mechanism that triggers their overall uplift. We speculate that the compression in the lithosphere gradually increased during the Cenozoic. The many mountain belts at active margins that accompany this event readily witness this increase. Less clear is how that compression increase affects passive margins. In order to address this issue, we design minimalist 2D viscous models to quantify the impact of plate collision on the stress regime. In these models, a sluggish plate is disposed on a less viscous mantle. It is driven by a "mantle conveyor belt" alternatively excited by lateral shear stresses that represent a downwelling on one side, an upwelling on the other side, or both simultaneously. The lateral edges of the plate are either free or fixed, respectively representing the cases of free convergence and collision. In practice, it dramatically changes the upper boundary condition for mantle circulation and subsequently, for the stress field. The flow pattern transiently evolves almost between two end-members, starting from a situation close to a Couette flow to a pattern that looks like a Poiseuille flow with an almost null velocity at the surface (though in the models, the horizontal velocity at the surface is not strictly null, as the lithosphere deforms). In the second case, the lithosphere is highly stressed horizontally and deforms. For an equivalent bulk driving force, compression increases drastically at passive margins if upwellings are active because they push plates towards the collision. Conversely, if only downwellings are activated, compression occurs on one half of the plate and extension on the other half, because only the downwelling is pulling the plate. Thus, active upwellings underneath oceanic plates are required to explain compression at passive margins. This conclusion is corroborated by "real-Earth" 3D spherical models, wherein the flow is alternatively driven by density anomalies inferred from seismic tomography -and therefore include both downwellings at subduction zones and upwellings above the superswells- and density anomalies that correspond to subducting slabs only. While the second scenario mostly compresses the active margins of upper plates and leave other areas at rest, the first scenario efficiently compresses passive margins where the geological record reveals their uplift, exhumation, and tectonic inversion.

  2. Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates

    PubMed Central

    Ganesh, VK; Ramakrishna, K; Ghista, Dhanjoo N

    2005-01-01

    Background In the internal fixation of fractured bone by means of bone-plates fastened to the bone on its tensile surface, an on-going concern has been the excessive stress-shielding of the bone by the excessively-stiff stainless-steel plate. The compressive stress-shielding at the fracture-interface immediately after fracture-fixation delays callus formation and bone healing. Likewise, the tensile stress-shielding of the layer of the bone underneath the plate can cause osteoporosis and decrease in tensile strength of this layer. Method In order to address this problem, we propose to use stiffness-graded plates. Accordingly, we have computed (by finite-element analysis) the stress distribution in the fractured bone fixed by composite plates, whose stiffness is graded both longitudinally and transversely. Results It can be seen that the stiffness-graded composite-plates cause less stress-shielding (as an example: at 50% of the healing stage, stress at the fracture interface is compressive in nature i.e. 0.002 GPa for stainless steel plate whereas stiffness graded plates provides tensile stress of 0.002 GPa. This means that stiffness graded plate is allowing the 50% healed bone to participate in loadings). Stiffness-graded plates are more flexible, and hence permit more bending of the fractured bone. This results in higher compressive stresses induced at the fractured faces accelerate bone-healing. On the other hand, away from the fracture interface the reduced stiffness and elastic modulus of the plate causes the neutral axis of the composite structure to be lowered into the bone resulting in the higher tensile stress in the bone-layer underneath the plate, wherein is conducive to the bone preserving its tensile strength. Conclusion Stiffness graded plates (with in-built variable stiffness) are deemed to offer less stress-shielding to the bone, providing higher compressive stress at the fractured interface (to induce accelerated healing) as well as higher tensile stress in the intact portion of the bone (to prevent bone remodeling and osteoporosis). PMID:16045807

  3. Fuel cell separator plate with bellows-type sealing flanges

    DOEpatents

    Louis, G.A.

    1984-05-29

    A fuel cell separator includes a rectangular flat plate having two unitary upper sealing flanges respectively comprising opposite marginal edges of the plate folded upwardly and back on themselves and two lower sealing flanges respectively comprising the other two marginal edges of the plate folded downwardly and back on themselves. Each of the sealing flanges includes a flat wall spaced from the plate and substantially parallel thereto and two accordion-pleated side walls, one of which interconnects the flat wall with the plate and the other of which steps just short of the plate, these side walls affording resilient compressibility to the sealing flange in a direction generally normal to the plane of the plate. Four corner members close the ends of the sealing flanges. An additional resiliently compressible reinforcing member may be inserted in the passages formed by each of the sealing flanges with the plate.

  4. Fuel cell separator plate with bellows-type sealing flanges

    DOEpatents

    Louis, George A.

    1986-08-05

    A fuel cell separator includes a rectangular flat plate having two unitary upper sealing flanges respectively comprising opposite marginal edges of the plate folded upwardly and back on themselves and two lower sealing flanges respectively comprising the other two marginal edges of the plate folded downwardly and back on themselves. Each of the sealing flanges includes a flat wall spaced from the plate and substantially parallel thereto and two accordion-pleated side walls, one of which interconnects the flat wall with the plate and the other of which stops just short of the plate, these side walls affording resilient compressibility to the sealing flange in a directiongenerally normal to the plane of the plate. Four corner members close the ends of the sealing flanges. An additional resiliently compressible reinforcing member may be inserted in the passages formed by each of the sealing flanges with the plate.

  5. Dilatation-dissipation corrections for advanced turbulence models

    NASA Technical Reports Server (NTRS)

    Wilcox, David C.

    1992-01-01

    This paper analyzes dilatation-dissipation based compressibility corrections for advanced turbulence models. Numerical computations verify that the dilatation-dissipation corrections devised by Sarkar and Zeman greatly improve both the k-omega and k-epsilon model predicted effect of Mach number on spreading rate. However, computations with the k-gamma model also show that the Sarkar/Zeman terms cause an undesired reduction in skin friction for the compressible flat-plate boundary layer. A perturbation solution for the compressible wall layer shows that the Sarkar and Zeman terms reduce the effective von Karman constant in the law of the wall. This is the source of the inaccurate k-gamma model skin-friction predictions for the flat-plate boundary layer. The perturbation solution also shows that the k-epsilon model has an inherent flaw for compressible boundary layers that is not compensated for by the dilatation-dissipation corrections. A compressibility modification for k-gamma and k-epsilon models is proposed that is similar to those of Sarkar and Zeman. The new compressibility term permits accurate predictions for the compressible mixing layer, flat-plate boundary layer, and a shock separated flow with the same values for all closure coefficients.

  6. Continious production of exfoliated graphite composite compositions and flow field plates

    DOEpatents

    Shi, Jinjun; Zhamu, Aruna; Jang, Bor Z.

    2010-07-20

    A process of continuously producing a more isotropic, electrically conductive composite composition is provided. The process comprises: (a) continuously supplying a compressible mixture comprising exfoliated graphite worms and a binder or matrix material, wherein the binder or matrix material is in an amount of between 3% and 60% by weight based on the total weight of the mixture; (b) continuously compressing the compressible mixture at a pressure within the range of from about 5 psi or 0.035 MPa to about 50,000 psi or 350 MPa in at least a first direction into a cohered graphite composite compact; and (c) continuously compressing the composite compact in a second direction, different from the first direction, to form the composite composition in a sheet or plate form. The process leads to composite plates with exceptionally high thickness-direction electrical conductivity.

  7. About DCP | Division of Cancer Prevention

    Cancer.gov

    The Division of Cancer Prevention (DCP) is the division of the National Cancer Institute (NCI) devoted to cancer prevention research. DCP provides funding and administrative support to clinical and laboratory researchers, community and multidisciplinary teams, and collaborative scientific networks. |

  8. Damage Progression in Buckle-Resistant Notched Composite Plates Loaded in Uniaxial Compression

    NASA Technical Reports Server (NTRS)

    McGowan, David M.; Davila, Carlos G.; Ambur, Damodar R.

    2001-01-01

    Results of an experimental and analytical evaluation of damage progression in three stitched composite plates containing an angled central notch and subjected to compression loading are presented. Parametric studies were conducted systematically to identify the relative effects of the material strength parameters on damage initiation and growth. Comparisons with experiments were conducted to determine the appropriate in situ values of strengths for progressive failure analysis. These parametric studies indicated that the in situ value of the fiber buckling strength is the most important parameter in the prediction of damage initiation and growth in these notched composite plates. Analyses of the damage progression in the notched, compression-loaded plates were conducted using in situ material strengths. Comparisons of results obtained from these analyses with experimental results for displacements and axial strains show good agreement.

  9. Bending of Rectangular Plates with Large Deflections

    NASA Technical Reports Server (NTRS)

    Levy, Samuel

    1942-01-01

    The solution of von Karman's fundamental equations for large deflections of plates is presented for the case of a simply supported rectangular plate under combined edge compression and lateral loading. Numerical solutions are given for square plates and for rectangular plates with a width-span ratio of 3:1. The effective widths under edge compression are compared with effective widths according to von Karman, Bengston, Marguerre, and Cox and with experimental results by Ramberg, McPherson, and Levy. The deflections for a square plate under lateral pressure are compared with experimental and theoretical results by Kaiser. It is found that the effective widths agree closely with Marguerre's formula and with the experimentally observed values and that the deflections agree with the experimental results and with Kaiser's work.

  10. Experimental and theoretical study of the buckling of narrow thin plates on an elastic foundation under compression

    NASA Astrophysics Data System (ADS)

    Kurguzov, V. D.; Demeshkin, A. G.

    2016-05-01

    The paper describes the processes of elastic deformation of thin films under mechanical loading. The film is modeled longitudinally by a compressed plate arranged on an elastic foundation. A computer model of the buckling of the narrow thin plate with a delamination portion located on an elastic foundation is constructed. This paper also touches upon the supercritical behavior of the plate-substrate system. The experiments on the axial compression of a metal strip adhered to a rubber plate are performed, and 2 to 7 buckling modes are obtained therein. The critical loads and buckling modes obtained in the numerical calculations are compared with the experimental data. It is shown that there is the possibility of progressive delamination of the metal plate from the foundation if the critical load is exceeded. It is found that the use of the proposed approach, which, in contrast to other approaches, accounts for the elastic deformation of the substrate, causes the dependence between the critical bending stress and the stiffness of the foundation.

  11. Buckling analysis for axially compressed flat plates, structural sections, and stiffened plates reinforced with laminated composites

    NASA Technical Reports Server (NTRS)

    Viswanathan, A. V.; Soong, T.; Miller, R. E., Jr.

    1971-01-01

    A classical buckling analysis is developed for stiffened, flat plates composed of a series of linked plate and beam elements. Plates are idealized as multilayered orthotropic elements. Structural beads and lips are idealized as beams. The loaded edges of the stiffened plate are simply-supported and the conditions at the unloaded edges can be prescribed arbitrarily. The plate and beam elements are matched along their common junctions for displacement continuity and force equilibrium in an exact manner. Offsets between elements are considered in the analysis. Buckling under uniaxial compressive load for plates, sections, and stiffened plates is investigated. Buckling loads are the lowest of all possible general and local failure modes, and the mode shape is used to determine whether buckling is a local or general instability. Numerical correlations with existing analysis and test data for plates, sections, and stiffened plates including boron-reinforced structures are discussed. In general correlations are reasonably good.

  12. Diagnostic accuracy of des-gamma-carboxy prothrombin for hepatocellular carcinoma in a French cohort using the Lumipulse® G600 analyzer.

    PubMed

    Sultanik, P; Ginguay, A; Vandame, J; Popovici, T; Meritet, J-F; Cynober, L; Pol, S; Bories, P-N

    2017-01-01

    The increasing incidence of hepatocellular carcinoma (HCC) in Western countries requests reliable tumour markers for preclinical diagnosis. We evaluated the diagnostic accuracy of des-gamma-carboxy prothrombin (DCP), in comparison with alpha-fetoprotein (AFP) in a French cohort using a new analyser. One hundred and sixty-two patients with virus-related cirrhosis (46 HCC patients and 116 controls) were recruited in this retrospective proof-of-concept study. DCP was measured on new Lumipulse ® G600 analyzer and AFP on usual Cobas e602 analyzer in serum samples that were collected at the time of HCC diagnosis for HCC patients or during follow-up for controls. DCP and AFP levels were higher in HCC patients. The area under receiver operating characteristic curve was larger for DCP than for AFP (0.89 vs 0.77, P=.03). At the cut-off value of 128 mAU/mL, sensitivity and specificity for DCP were 74% and 92%. At the cut-off value of 20 μg/L, sensitivity and specificity for AFP were 63% and 82%. NRI >0 for the association of "AFP+DCP" were 101%, P<.0001, and 23%, P=.03, compared to "AFP" or "DCP" alone, respectively. We conclude that DCP outperformed AFP for the detection of HCC. © 2016 John Wiley & Sons Ltd.

  13. Buckling behavior of long symmetrically laminated plates subjected to combined loadings

    NASA Technical Reports Server (NTRS)

    Nemeth, Michael P.

    1992-01-01

    A parametric study is presented of the buckling behavior of infinitely long, symmetrically laminated anisotropic plates subjected to combined loadings. The loading conditions considered are axial tension and compression transverse tension and compression, and shear. Results obtained using a special-purpose analysis, well-suited for parametric studies, are presented for clamped and simply supported plates. Moreover, results are presented for some common laminate constructions, and generic buckling design charts are presented for a wide range of parameters. The generic design charts are presented in terms of useful nondimensional parameters, and the dependence of the nondimensional parameters on laminate fiber orientation, stacking sequence, and material properties is discussed. An important finding of the study is that the effects of anisotropy are much more pronounced in shear-loaded plates than in compression-loaded plates. In addition, the effects of anisotropy on plates subjected to combined loadings are generally manifested as a phase shift of self-similar buckling interaction curves. A practical application of this phase shift is that the buckling resistance of long plates can be improved by applying a shear loading with a specific orientation. In all cases considered in the study, the buckling coefficients of infinitely long plates are found to be independent of the bending stiffness ratio (D sub 11/D sub 22)(1/4).

  14. Buckling behavior of long symmetrically laminated plates subjected to combined loads

    NASA Technical Reports Server (NTRS)

    Nemeth, Michael P.

    1992-01-01

    A parametric study of the buckling behavior of infinitely long symmetrically laminated anisotropic plates subjected to combined loadings is presented. The loading conditions considered are axial tension and compression, transverse tension and compression, and shear. Results obtained using a special purpose analysis, well suited for parametric studies are presented for clamped and simply supported plates. Moreover, results are presented for some common laminate constructions, and generic buckling design charts are presented for a wide range of parameters. The generic design charts are presented in terms of useful nondimensional parameters, and dependence of the nondimensional parameters on laminate fiber orientation, stacking sequence, and material properties is discussed. An important finding of the study is that the effects of anisotropy are much more pronounced in shear-loaded plates than in compression loaded plates. In addition, the effects of anisotropy on plates subjected to combined loadings are generally manifested as a phase shift of self-similar buckling interaction curves. A practical application of this phase shift is the buckling resistance of long plates can be improved by applying a shear loading with a specific orientation. In all cases considered, it is found that the buckling coefficients of infinitely long plates are independent of the bending stiffness ratio (D sub 11/D sub 22) sup 1/4.

  15. Dual small fragment plating improves screw-to-screw load sharing for mid-diaphyseal humeral fracture fixation: a finite element study.

    PubMed

    Kosmopoulos, Victor; Luedke, Colten; Nana, Arvind D

    2015-01-01

    A smaller humerus in some patients makes the use of a large fragment fixation plate difficult. Dual small fragment plate constructs have been suggested as an alternative. This study compares the biomechanical performance of three single and one dual plate construct for mid-diaphyseal humeral fracture fixation. Five humeral shaft finite element models (1 intact and 4 fixation) were loaded in torsion, compression, posterior-anterior (PA) bending, and lateral-medial (LM) bending. A comminuted fracture was simulated by a 1-cm gap. Fracture fixation was modelled by: (A) 4.5-mm 9-hole large fragment plate (wide), (B) 4.5-mm 9-hole large fragment plate (narrow), (C) 3.5-mm 9-hole small fragment plate, and (D) one 3.5-mm 9-hole small fragment plate and one 3.5-mm 7-hole small fragment plate. Model A showed the best outcomes in torsion and PA bending, whereas Model D outperformed the others in compression and LM bending. Stress concentrations were located near and around the unused screw holes for each of the single plate models and at the neck of the screws just below the plates for all the models studied. Other than in PA bending, Model D showed the best overall screw-to-screw load sharing characteristics. The results support using a dual small fragment locking plate construct as an alternative in cases where crutch weight-bearing (compression) tolerance may be important and where anatomy limits the size of the humerus bone segment available for large fragment plate fixation.

  16. SU-F-T-91: Development of Real Time Abdominal Compression Force (ACF) Monitoring System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, T; Kim, D; Kang, S

    Purpose: Hard-plate based abdominal compression is known to be effective, but no explicit method exists to quantify abdominal compression force (ACF) and maintain the proper ACF through the whole procedure. In addition, even with compression, it is necessary to do 4D CT to manage residual motion but, 4D CT is often not possible due to reduced surrogating sensitivity. In this study, we developed and evaluated a system that both monitors ACF in real time and provides surrogating signal even under compression. The system can also provide visual-biofeedback. Methods: The system developed consists of a compression plate, an ACF monitoring unitmore » and a visual-biofeedback device. The ACF monitoring unit contains a thin air balloon in the size of compression plate and a gas pressure sensor. The unit is attached to the bottom of the plate thus, placed between the plate and the patient when compression is applied, and detects compression pressure. For reliability test, 3 volunteers were directed to take several different breathing patterns and the ACF variation was compared with the respiratory flow and external respiratory signal to assure that the system provides corresponding behavior. In addition, guiding waveform were generated based on free breathing, and then applied for evaluating the effectiveness of visual-biofeedback. Results: We could monitor ACF variation in real time and confirmed that the data was correlated with both respiratory flow data and external respiratory signal. Even under abdominal compression, in addition, it was possible to make the subjects successfully follow the guide patterns using the visual biofeedback system. Conclusion: The developed real time ACF monitoring system was found to be functional as intended and consistent. With the capability of both providing real time surrogating signal under compression and enabling visual-biofeedback, it is considered that the system would improve the quality of respiratory motion management in radiation therapy. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)« less

  17. Instability of fiber-reinforced viscoelastic composite plates to in-plane compressive loads

    NASA Technical Reports Server (NTRS)

    Chandiramani, N. K.; Librescu, L.

    1990-01-01

    This study analyzes the stability behavior of unidirectional fiber-reinforced composite plates with viscoelastic material behavior subject to in-plane biaxial compressive edge loads. To predict the effective time-dependent material properties, elastic fibers embedded in a linearly viscoelastic matrix are examined. The micromechanical relations developed for a transversely isotropic medium are discussed along with the correspondence principle of linear viscoelasticity. It is concluded that the stability boundary obtained for a viscoelastic plate is lower (more critical) than its elastic counterpart, and the transverse shear deformation effects are more pronounced in viscoelastic plates than in their elastic counterparts.

  18. Charts relating the compressive buckling stress of longitudinally supported plates to the effective deflectional and rotational stiffness of the supports

    NASA Technical Reports Server (NTRS)

    Anderson, Roger A; Semonian, Joseph W

    1954-01-01

    A stability analysis is made of a long flat rectangular plate subjected to a uniform longitudinal compressive stress and supported along its longitudinal edges and along one or more longitudinal lines by elastic line supports. The elastic supports possess deflectional and rotational stiffness. Such configuration is an idealization of the compression cover skin and internal structure of a wing and tail surfaces. The results of the analysis are presented in the form of charts in which the buckling-stress coefficient is plotted against the buckle length of the plate for a wide range of support stiffnesses. The charts make possible the determination of the compressive buckling stress of plates supported by members whose stiffness may or may not be defined by elementary beam bending and twisting theory but yet whose effective restraint is amenable to evaluation. The deflectional and rotational stiffness provided by longitudinal stiffeners and full-depth webs is discussed and numerical examples are given to illustrate the application of the charts to the design of wing structures.

  19. Disposition and metabolism of 2,3-( UC)dichloropropene in rats after inhalation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bond, J.A.; Medinsky, M.A.; Dutcher, J.S.

    1985-01-01

    2,3-Dichloropropene (2,3-DCP) is a constituent of some commercially available preplant soil fumigants for the control of plant parasitic nematodes. The purpose of this investigation was to determine the disposition and metabolism of 2,3-( UC)DCP in rats after inhalation. Male Fischer-344 rats were exposed nose-only to a vapor concentration of 250 nmol 2,3-( UC)DCP/liter air (7.5 ppm; 25C, 620 Torr) for 6 hr. Blood samples were taken during exposure, and urine, feces, expired air, and tissues were collected for up to 65 hr after exposure. Urinary excretion was the major route of elimination of UC (55% of estimated absorbed 2,3-DCP). Half-timemore » for elimination of UC in urine was 9.8 +/- 0.05 hr (anti x +/- SE). Half-time for elimination of UC feces (17% of absorbed 2,3-DCP) was 12.9 +/- 0.14 hr (anti x +/- SE). Approximately 1 and 3% of the estimated absorbed 2,3-( UC)DCP were exhaled as either 2,3-( UC)DCP or UCO2, respectively. Concentrations of UC in blood increased during 240 min of exposure, after which no further increases in blood concentration of UC were seen. UC was widely distributed in tissues analyzed after a 6-hr exposure of rats to 2,3-( UC)DCP. Urinary bladder (150 nmol/g), nasal turbinates (125 nmol/g), kidneys (84 nmol/g), small intestine (61 nmol/g), and liver (35 nmol/g) were tissues with the highest concentrations of UC immediately after exposure. Over 90% of the UC in tissues analyzed was 2,3-DCP metabolites. Half-times for elimination of UC from tissues examined ranged from 3 to 11 hr. The data from this study indicate that after inhalation 2,3-DCP is metabolized in tissues and readily excreted. 21 references. 2 figures, 4 tables.« less

  20. Environmental effects on the compressive properties - Thermosetting vs. thermoplastic composites

    NASA Technical Reports Server (NTRS)

    Haque, A.; Jeelani, S.

    1992-01-01

    The influence of moisture and temperature on the compressive properties of graphite/epoxy and APC-2 materials systems was investigated to assess the viability of using APC-2 instead of graphite/epoxy. Data obtained indicate that the moisture absorption rate of T-300/epoxy is higher than that of APC-2. Thick plate with smaller surface area absorbs less moisture than thin plate with larger surface area. The compressive strength and modulus of APC-2 are higher than those of T-300/epoxy composite, and APC-2 sustains higher compressive strength in the presence of moisture. The compressive strength and modulus decrease with the increase of temperature in the range of 23-100 C. The compression failure was in the form of delamination, interlaminar shear, and end brooming.

  1. Fate and origin of 1,2 - dichloropropane in an unconfined shallow aquifer

    USGS Publications Warehouse

    Tesoriero, Anthony J.; Loffler, F.E.; Liebscher, Hugh

    2001-01-01

    A shallow aquifer with different redox zones overlain by intensive agricultural activity was monitored for the occurrence of 1,2-dichloropropane (DCP) to assess the fate and origin of this pollutant. DCP was detected more frequently in groundwater samples collected in aerobic and nitrate-reducing zones than those collected from iron-reducing zones. Simulated DCP concentrations for groundwater entering an iron-reducing zone were calculated from a fate and transport model that included dispersion, sorption, and hydrolysis but not degradation. Simulated concentrations were well in excess of measured values, suggesting that microbial degradation occurred in the iron-reducing zone. Microcosm experiments were conducted using aquifer samples collected from iron-reducing and aerobic zones to evaluate the potential for microbial degradation of DCP and to explain field observations. Hydrogenolysis of DCP and production of monochlorinated propanes in microcosm experiments occurred only with aquifer materials collected from the iron-reducing zone, and no dechlorination was observed in microcosms established with aquifer materials collected from the aerobic zones. Careful analyses of the DCP/1,2,2-trichloropropane ratios in groundwater indicated that older fumigant formulations were responsible for the high levels of DCP present in this aquifer.

  2. Differential utilization of decapping enzymes in mammalian mRNA decay pathways

    PubMed Central

    Li, You; Song, Mangen; Kiledjian, Megerditch

    2011-01-01

    mRNA decapping is a crucial step in the regulation of mRNA stability and gene expression. Dcp2 is an mRNA decapping enzyme that has been widely studied. We recently reported the presence of a second mammalian cytoplasmic decapping enzyme, Nudt16. Here we address the differential utilization of the two decapping enzymes in specified mRNA decay processes. Using mouse embryonic fibroblast (MEF) cell lines derived from a hypomorphic knockout of the Dcp2 gene with undetectable levels of Dcp2 or MEF cell lines harboring a Nudt16-directed shRNA to generate reduced levels of Nudt16, we demonstrate the distinct roles for Dcp2 and Nudt16 in nonsense-mediated mRNA decay (NMD), decay of ARE-containing mRNA and miRNA-mediated silencing. Our results indicated that NMD preferentially utilizes Dcp2 rather than Nudt16; Dcp2 and Nudt16 are redundant in miRNA-mediated silencing; and Dcp2 and Nudt16 are differentially utilized for ARE-mRNA decay. These data demonstrate that the two distinct decapping enzymes can uniquely function in specific mRNA decay processes in mammalian cells. PMID:21224379

  3. Stalagmite carbon isotopes and dead carbon proportion (DCP) in a near-closed-system situation: An interplay between sulphuric and carbonic acid dissolution

    NASA Astrophysics Data System (ADS)

    Bajo, Petra; Borsato, Andrea; Drysdale, Russell; Hua, Quan; Frisia, Silvia; Zanchetta, Giovanni; Hellstrom, John; Woodhead, Jon

    2017-08-01

    In this study, the 'dead carbon proportion' (DCP) calculated from combined U-Th and radiocarbon analyses was used to explore the carbon isotope systematics in Corchia Cave (Italy) speleothems, using the example of stalagmite CC26 which grew during the last ∼12 ka. The DCP values in CC26 are among the highest ever recorded in a stalagmite, spanning the range 44.8-68.8%. A combination of almost closed-system conditions and sulphuric acid dissolution (SAD) are proposed as major drivers in producing such a high DCP with minor contribution from old organic matter from the deep vadose zone. The long-term decrease in both DCP and δ13C most likely reflects post-glacial soil recovery above the cave, with a progressive increase of soil CO2 contribution to the total dissolved inorganic carbon (DIC). Pronounced millennial-scale shifts in DCP and relatively small coeval but antipathetic changes in δ13C are modulated by the effects of hydrological variability on open and closed-system dissolution, SAD and prior calcite precipitation. Hence, the DCP in Corchia Cave speleothems represents an additional proxy for rainfall amount.

  4. Rapid and early α-fetoprotein and des-γ-carboxy prothrombin responses to initial arterial infusion chemotherapy predict treatment outcomes of advanced hepatocellular carcinoma

    PubMed Central

    OYAMA, KENJI; KODA, MASAHIKO; SUGIHARA, TAKAAKI; KISHINA, MANABU; MIYOSHI, KENICHI; OKAMOTO, TOSHIAKI; HODOTSUKA, MASANORI; FUJISE, YUKI; MATONO, TOMOMITSU; TOKUNAGA, SHIHO; OKAMOTO, KINYA; HOSHO, KEIKO; OKANO, JUNICHI; MURAWAKI, YOSHIKAZU

    2015-01-01

    The aim of the present study was to predict the effects of transarterial infusion (TAI) chemotherapy based on early changes in α-fetoprotein (AFP) and des-γ-carboxy prothrombin (DCP) in patients with advanced hepatocellular carcinoma (HCC). Seventy-four patients who underwent TAI with cisplatin, 5-fluorouracil, mitomycin C and epirubicin for advanced HCC were enrolled. Antitumor responses were evaluated 6 months after TAI. Rapid and early responses were defined as the ratio of AFP or DCP after 1 week and 1 month compared to baseline. A total of 5, 10, 17 and 42 patients had complete response (CR), partial response (PR), stable disease (SD) or progressive disease (PD), respectively. Early AFP response was significantly lower in the CR+PR compared to the SD+PD groups (P<0.01). The early DCP response was significantly lower in the CR+PR compared to the SD+PD. The sensitivity and specificity of rapid and early AFP responses in the CR+PR were 0.78 and 0.72, and 0.80 and 0.73, respectively, and those of rapid and early DCP responses were 0.67 and 0.65, and 0.77 and 0.71, respectively. The combination of AFP and DCP responses had higher specificity compared to AFP or DCP alone responses. Patients were divided into responder and non-responder groups to evaluate the prediction of survival outcome. Early responders of AFP, DCP and AFP+DCP, who were divided based on the cut-off values of CR+PR survived significantly longer than the non-responders (P<0.05). In conclusion, rapid or early responses of AFP and/or DCP levels 1 and 4 weeks after TAI chemotherapy helped to predict the treatment effects. PMID:26137283

  5. Effect of wheat bran and dried carrot pomace addition on quality characteristics of chicken sausage

    PubMed Central

    2018-01-01

    Objective Effect of addition of wheat bran (WB) and dried carrot pomace (DCP) on sensory, textural, colour, physico-chemical and nutritional characteristics of chicken sausage were evaluated. Methods WB and DCP were used as a source of dietary fibre at 3%, 6%, and 9% level individually. Different quality attributes of sausages were estimated. One product from each source with very good sensory acceptability was selected to analyze dietary fibre content and shelf life under refrigerated storage. Results Sensory acceptability of 3% fibre enriched sausage was comparable with control and a further increase in fibre level resulted in a decrease in sensory acceptability. Fibre enriched sausages were significantly harder and less cohesive than control sausage. Significant increase in gumminess and chewiness was observed at 6% level in WB treated sausages and 9% level in DCP treated sausages. Moisture content decreased significantly in all treated sausages, protein content decreased significantly in DCP-2 and DCP-3 sausages while fat content decreased in all WB and DCP-3 treated sausages in comparison to control. The fibre enriched sausage had significantly higher dietary fibre and lower cholesterol content. Cooking yield and emulsion stability increased in treated sausages and a significant difference was noticed at 6% level in both types of sausages. pH of WB treated sausages was significantly higher and DCP treated sausage significantly lower in comparison to control. Conclusion The results of present study indicate that fibre enriched chicken sausage with moderate acceptability can be developed by incorporating WB and DCP each up to 9% level. Chicken sausage with very good acceptability, higher dietary fibre content and storability up to 15 days at refrigerated temperature can be developed by incorporating WB and DCP at 6% level each. PMID:28823131

  6. [Experimental study on Dendrobium candidum polysaccharides on promotion of hair growth].

    PubMed

    Chen, Jian; Qi, Hui; Li, Jin-Biao; Yi, Yan-Qun; Chen, Dan; Hu, Xiao-Hong; Wang, Mei-Ling; Sun, Xing-Li; Wei, Xiao-Yong

    2014-01-01

    To observe the effect and mechanism of Dendrobium candidum polysaccharides (DCP) in promoting hair growth, in order to lay a foundation for the development and utilization of D. candidum. The water-extraction and alcohol-precipitation method was adopted to extract DCP, and the phenol-sulphuric acid method was used to determine its content. Thirty C57BL6J mice were collected to establish the hair loss model with hair removal cream. They were randomly divided into the control group, the positive control group and the DCP group, and given 0.2 mL of ultra-pure water, minoxidil tincture and DCP (5.0 g x L(-1)) 21 days. The mice hair growth scoring standard was adopted to evaluate the hair growth of C57BL/6J mice at 7, 14 d. The hairs in unit hair-losing areas of treated C57BL/6J mice at 21 d were weighed to evaluate the effect of DCP on the promotion of hair growth. MTT assay and RT-PCR method were used to evaluate the effect of DCP on the proliferatin of HaCaT cells and the mRNA expression of VEGF in HaCaT cells. The extraction percent of DCP was 29.87%, and its content was 79.65%. The average scores for the hair growth and weight of C57BL/6J mice of DCP group were much higher than the control group. The survival rate and mRNA expression of VEGF of HaCaT cells were much higher than the control group. DCP has the effect in promoting hair growth. Its mechanism may be related to the up-regulation of the mRNA expression of VEGF.

  7. Finite-Difference Solutions for Compressible Laminar Boundary-Layer Flows of a Dusty Gas over a Semi-Infinite Flat Plate.

    DTIC Science & Technology

    1986-08-01

    AD-A174 952 FINITE - DIFFERENCE SOLUTIONS FOR CONPRESSIBLE LANINAR 1/2 BOUNDARY-LAYER FLOUS (U) TORONTO UNIV DOWNSVIEW (ONTARIO) INST FOR AEROSPACE...dilute dusty gas over a semi-infinite flat plate. Details are given of the impliit finite , difference schemes as well as the boundary conditions... FINITE - DIFFERENCE SOLUTIONS FOR COMPRESSIBLE LAMINAR BOUNDARY-LAYER FLOWS OF A DUSTY GAS OVER A SEMI-INFINITE FLAT PLATE by B. Y. Wang and I. I

  8. Stability and Process of Destruction of Compressed Plate of Layered Composite Materials With Defects

    NASA Astrophysics Data System (ADS)

    Bokhoeva, L. A.; Rogov, V. E.; Chermoshentseva, A. S.; Lobanov, D. V.

    2016-08-01

    Interlayer defects in composite materials are a pressing problem, which affecting their performance characteristics. In this research, we considered the problem of the stability and of the fracture process of the compressed thin plate made of laminated composite materials with the interlayer defects. In this research we had got a critical equation for a plate with interlayer defect. The experiment showed the effect and the quantity of nano-dispersed additives on the mechanical properties of composite materials with interlayer defects.

  9. Blended-Wing-Body Structural Technology Study

    NASA Technical Reports Server (NTRS)

    Starnes, James H.

    1998-01-01

    In most studies of stability of plates, the axial stress has been taken as uniform compression throughout flat rectangular plates. Buckling of isotropic plates under a compressive stress that varies linearly from one loaded edge to the other has been studied by Libove et al. Cases of practical interest exist, however, in which the axial stress is not uniform but varies from tension at both loaded edges to compression in the middle. An example is the stability of the crown of the hat stiffened panel, a candidate configuration of the upper and lower skin of the Blended Wing Body (BWB) Aircraft. The BWB Aircraft is an advanced long-range ultra-high-capacity airliner with the principal feature being the pressurized wide double-deck body which is blended into the wing. In the present research, analytical methods are used to investigate the local stability of the crown in order to minimize its weight while optimizing its buckling strength. The crown is modeled as a rectangular laminated composite plate subjected to a second degree parabolic variation of axial stresses in the longitudinal direction. A varying tension-compression- tension axial stresses are induced in the crown of the stiffeners due to bending. The change in axial stresses is equilibrated by nonuniform shear stresses along the plate edges and transverse normal stresses.

  10. Active vibration control of structures undergoing bending vibrations

    NASA Technical Reports Server (NTRS)

    Pla, Frederic G. (Inventor); Rajiyah, Harindra (Inventor)

    1995-01-01

    An active vibration control subassembly for a structure (such as a jet engine duct or a washing machine panel) undergoing bending vibrations caused by a source (such as the clothes agitator of the washing machine) independent of the subassembly. A piezoceramic actuator plate is vibratable by an applied electric AC signal. The plate is connected to the structure such that vibrations in the plate induced by the AC signal cause canceling bending vibrations in the structure and such that the plate is compressively pre-stressed along the structure when the structure is free of any bending vibrations. The compressive prestressing increases the amplitude of the canceling bending vibrations before the critical tensile stress level of the plate is reached. Preferably, a positive electric DC bias is also applied to the plate in its poling direction.

  11. Identification of functional domains in Arabidopsis thaliana mRNA decapping enzyme (AtDcp2)

    PubMed Central

    Gunawardana, Dilantha; Cheng, Heung-Chin; Gayler, Kenwyn R.

    2008-01-01

    The Arabidopsis thaliana decapping enzyme (AtDcp2) was characterized by bioinformatics analysis and by biochemical studies of the enzyme and mutants produced by recombinant expression. Three functionally significant regions were detected: (i) a highly disordered C-terminal region with a putative PSD-95, Discs-large, ZO-1 (PDZ) domain-binding motif, (ii) a conserved Nudix box constituting the putative active site and (iii) a putative RNA binding domain consisting of the conserved Box B and a preceding loop region. Mutation of the putative PDZ domain-binding motif improved the stability of recombinant AtDcp2 and secondary mutants expressed in Escherichia coli. Such recombinant AtDcp2 specifically hydrolysed capped mRNA to produce 7-methyl GDP and decapped RNA. AtDcp2 activity was Mn2+- or Mg2+-dependent and was inhibited by the product 7-methyl GDP. Mutation of the conserved glutamate-154 and glutamate-158 in the Nudix box reduced AtDcp2 activity up to 400-fold and showed that AtDcp2 employs the catalytic mechanism conserved amongst Nudix hydrolases. Unlike many Nudix hydrolases, AtDcp2 is refractory to inhibition by fluoride ions. Decapping was dependent on binding to the mRNA moiety rather than to the 7-methyl diguanosine triphosphate cap of the substrate. Mutational analysis of the putative RNA-binding domain confirmed the functional significance of an 11-residue loop region and the conserved Box B. PMID:18025047

  12. Analysis of 3-MCPD and 1,3-DCP in Various Foodstuffs Using GC-MS

    PubMed Central

    Kim, Wooseok; Jeong, Yun A; On, Jiwon; Choi, Ari; Lee, Jee-yeon; Lee, Joon Goo; Lee, Kwang-Geun

    2015-01-01

    3-Monochloro-1,2-propanediol (3-MCPD) and 1,3-dichloro-2-propanol (1,3-DCP) are not only produced in the manufacturing process of foodstuffs such as hydrolyzed vegetable proteins and soy sauce but are also formed by heat processing in the presence of fat and low water activity. 3-MCPD exists both in free and ester forms, and the ester form has been also detected in various foods. Free 3-MCPD and 1,3-DCP are classified as Group 2B by the International Agency for Research on Cancer. Although there is no data confirming the toxicity of either compound in humans, their toxicity was evidenced in animal experimentation or in vitro. Although few studies have been conducted, free 3-MCPD has been shown to have neurotoxicity, reproductive toxicity, and carcinogenicity. In contrast, 1,3-DCP only has mutagenic activity. The purpose of this study was to analyze 3-MCPD and 1,3-DCP in various foods using gas chromatography -mass spectrometry. 3-MCPD and 1,3-DCP were analyzed using phenyl boronic acid derivatization and the liquid–liquid extraction method, respectively. The analytical method for 3-MCPD and 1,3-DCP was validated in terms of linearity, limit of detection (LOD), limit of quantitation, accuracy and precision. Consequently, the LODs of 3-MCPD and 1,3-DCP in various matrices were identified to be in the ranges of 4.18~10.56 ng/g and 1.06~3.15 ng/g, respectively. PMID:26483891

  13. Spin ejector

    DOEpatents

    Andersen, John A.; Flanigan, John J.; Kindley, Robert J.

    1978-01-01

    The disclosure relates to an apparatus for spin ejecting a body having a flat plate base containing bosses. The apparatus has a base plate and a main ejection shaft extending perpendicularly from the base plate. A compressible cylindrical spring is disposed about the shaft. Bearings are located between the shaft and the spring. A housing containing a helical aperture releasably engages the base plate and surrounds the shaft bearings and the spring. A piston having an aperture follower disposed in the housing aperture is seated on the spring and is guided by the shaft and the aperture. The spring is compressed and when released causes the piston to spin eject the body.

  14. Environmental effects on the compressive properties - Thermosetting vs. thermoplastic composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haque, A.; Jeelani, S.

    1992-02-01

    The influence of moisture and temperature on the compressive properties of graphite/epoxy and APC-2 materials systems was investigated to assess the viability of using APC-2 instead of graphite/epoxy. Data obtained indicate that the moisture absorption rate of T-300/epoxy is higher than that of APC-2. Thick plate with smaller surface area absorbs less moisture than thin plate with larger surface area. The compressive strength and modulus of APC-2 are higher than those of T-300/epoxy composite, and APC-2 sustains higher compressive strength in the presence of moisture. The compressive strength and modulus decrease with the increase of temperature in the range ofmore » 23-100 C. The compression failure was in the form of delamination, interlaminar shear, and end brooming. 9 refs.« less

  15. 75 FR 38802 - DCP Raptor Pipeline, LLC; Notice of Baseline Filing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-06

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-42-000] DCP Raptor Pipeline, LLC; Notice of Baseline Filing June 28, 2010. Take notice that on June 22, 2010, DCP Raptor Pipeline, LLC submitted a baseline filing of its Statement of Operating Conditions for services provided...

  16. 76 FR 47576 - DCP Intrastate Network, LLC; Notice of Filing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-05

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-120-000] DCP Intrastate Network, LLC; Notice of Filing Take notice that on July 26, 2011, DCP Intrastate Network, LLC filed to provide notice of its cancellation of its Statement of Operating Conditions for Interstate Gas...

  17. 76 FR 9012 - DCP Intrastate Network, LLC; Notice of Filing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-16

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-85-000] DCP Intrastate Network, LLC; Notice of Filing Take notice that on February 1, 2011, DCP Intrastate Network, LLC (DCPIN) filed to provide notice of its withdrawal of rates for transportation service under Section 311 of the...

  18. 75 FR 37786 - DCP Guadalupe Pipeline, LLC; Notice of Baseline Filing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-30

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-31-000] DCP Guadalupe Pipeline, LLC; Notice of Baseline Filing June 23, 2010. Take notice that on June 10, 2010, DCP Guadalupe Pipeline, LLC submitted a baseline filing of its Storage Statement of Operating Conditions for services...

  19. 76 FR 7552 - DCP Guadalupe Pipeline, LLC; Notice of Baseline Filing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-10

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [ Docket No. PR10-31-001] DCP Guadalupe Pipeline, LLC; Notice of Baseline Filing Take notice that on February 3, 2011, DCP Guadalupe Pipeline, LLC submitted a revised baseline filing of their Statement of Operating Conditions for services provided under...

  20. The Diaper Change Play: Validation of a New Observational Assessment Tool for Early Triadic Family Interactions in the First Month Postpartum.

    PubMed

    Rime, Jérôme; Tissot, Hervé; Favez, Nicolas; Watson, Michael; Stadlmayr, Werner

    2018-01-01

    The quality of family relations, observed during mother-father-infant triadic interactions, has been shown to be an important contributor to child social and affective development, beyond the quality of dyadic mother-child, father-child, and marital relationships. Triadic interactions have been well described in families with 3 month olds and older children using the Lausanne Trilogue Play (LTP). Little is known about the development of mother-father-baby interactions in the very 1st weeks postpartum, mostly because no specific observational setting or particular instrument had been designed to cover this age yet. To fill this gap, we adapted the LTP to create a new observational setting, namely the Diaper Change Play (DCP). Interactions are assessed using the Family Alliance Assessment Scales for DCP (FAAS-DCP). We present the validation of the DCP and its coding system, the FAAS-DCP. The three validation studies presented here (44 mother-father-child-triads) involve a sample of parents with 3-week-old infants recruited in two maternity wards ( n = 32 and n = 12) in Switzerland. Infants from both sites were all healthy according to their APGAR scores, weight at birth, and scores on the NICU Network Neurobehavioral Scale (NNNS), which was additionally conducted on the twelve infants recruited in one of the maternity ward. Results showed that the "FAAS - DCP" coding system has good psychometric properties, with a good internal consistency and a satisfying reliability among the three independent raters. Finally, the "FAAS-DCP" scores on the interactive dimensions are comparable to the similar dimensions in the FAAS-LTP. The results showed that there is no statistically significant difference on scores between the "FAAS-DCP" and the "FAAS," which is consistent with previous studies underlying stability in triadic interaction patterns from pregnancy to 18 months. These first results indicated that the DCP is a promising observational setting, able to assess the development of the early family triadic functioning. The DCP and the FAAS-DCP offer to both clinicians and researchers a way to improve the understanding of the establishment of early family functioning as well as to study the young infant's triangular capacity. Perspectives for future research will be discussed.

  1. Plating by glass-bead peening

    NASA Technical Reports Server (NTRS)

    Babecki, A. J.; Haehner, C. L.

    1971-01-01

    Technique permits plating of primarily metallic substrates with either metals or nonmetals at normal temperature. Peening uses compressed air to apply concurrent streams of small glass beads and powdered plating material to the substrate.

  2. Buckling and postbuckling behavior of square compression-loaded graphite-epoxy plates with circular cutouts

    NASA Technical Reports Server (NTRS)

    Nemeth, Michael P.

    1990-01-01

    An experimental study of the postbuckling behavior of square compression-loaded graphite-epoxy plates and isotropic plates with a central circular cutout is presented. Results are presented for unidirectional (0 sub 10)s and (90 sub 10)s plates, (0/90 sub 5)s plates, and for aluminum plates. Results are also presented for (+ or - O sub 6)s angle-ply plates for values of O = 30, 46, and 60 degrees. The experimental results indicate that the change in axial stiffness of a plate at buckling is strongly dependent upon cutout size and plate orthotropy. The presence of a cutout gives rise to an internal load distribution that changes, sometimes dramtically, as a function of cutout size coupled with the plate orthotropy. In the buckled state, the role of orthotropy becomes more significant since bending in addition to membrane orthotropy is present. Most of the plates with cutouts exhibited less postbuckling stiffness than the corresponding plate without a cutout, and the postbuckling stiffness decreased with increasing cutout size. However, some of the highly orthotropic plates with cutouts exhibited more postbuckling stiffness than the corresponding plate without a cutout.

  3. Fuel cell separator with compressible sealing flanges

    DOEpatents

    Mientek, A.P.

    1984-03-30

    A separator for separating adjacent fuel cells in a stack of such cells includes a flat, rectangular, gas-impermeable plate disposed between adjacent cells and having two opposite side margins thereof folded back over one side of the plate to form two first seal flanges and having the other side margins thereof folded back over the opposite side of the plate to form two second seal flanges, each of the seal flanges cooperating with the plate to define a channel in which is disposed a resiliently compressible stack of thin metal sheets. The two first seal flanges cooperate with the electrolyte matrix of one of the cells to form a gas-impermeable seal between an electrode of the one cell and one of two reactant gas manifolds. The second seal flanges cooperate with the electrolyte matrix of the other cell for forming a gas-impermeable seal between an electrode of the other cell and the other of the two reactant gas manifolds. The seal flanges cooperate with the associated compressible stacks of sheets for maintaining a spacing between the plate and the electrolyte matrices while accommodating variation of that spacing.

  4. Fuel cell separator with compressible sealing flanges

    DOEpatents

    Mientek, Anthony P.

    1985-04-30

    A separator for separating adjacent fuel cells in a stack of such cells includes a flat, rectangular, gas-impermeable plate disposed between adjacent cells and having two opposite side margins thereof folded back over one side of the plate to form two first seal flanges and having the other side margins thereof folded back over the opposite side of the plate to form two second seal flanges, each of the seal flanges cooperating with the plate to define a channel in which is disposed a resiliently compressible stack of thin metal sheets. The two first seal flanges cooperate with the electrolyte matrix of one of the cells to form a gas-impermeable seal between an electrode of the one cell and one of two reactant gas manifolds. The second seal flanges cooperate with the electrolyte matrix of the other cell for forming a gas-impermeable seal between an electrode of the other cell and the other of the two reactant gas manifolds. The seal flanges cooperate with the associated compressible stacks of sheets for maintaining a spacing between the plate and the electrolyte matrices while accommodating variation of that spacing.

  5. Feasibility of in vivo three-dimensional T 2* mapping using dicarboxy-PROXYL and CW-EPR-based single-point imaging.

    PubMed

    Kubota, Harue; Komarov, Denis A; Yasui, Hironobu; Matsumoto, Shingo; Inanami, Osamu; Kirilyuk, Igor A; Khramtsov, Valery V; Hirata, Hiroshi

    2017-06-01

    The aim of this study was to demonstrate the feasibility of in vivo three-dimensional (3D) relaxation time T 2 * mapping of a dicarboxy-PROXYL radical using continuous-wave electron paramagnetic resonance (CW-EPR) imaging. Isotopically substituted dicarboxy-PROXYL radicals, 3,4-dicarboxy-2,2,5,5-tetra( 2 H 3 )methylpyrrolidin-(3,4- 2 H 2 )-(1- 15 N)-1-oxyl ( 2 H, 15 N-DCP) and 3,4-dicarboxy-2,2,5,5-tetra( 2 H 3 )methylpyrrolidin-(3,4- 2 H 2 )-1-oxyl ( 2 H-DCP), were used in the study. A clonogenic cell survival assay was performed with the 2 H-DCP radical using squamous cell carcinoma (SCC VII) cells. The time course of EPR signal intensities of intravenously injected 2 H, 15 N-DCP and 2 H-DCP radicals were determined in tumor-bearing hind legs of mice (C3H/HeJ, male, n = 5). CW-EPR-based single-point imaging (SPI) was performed for 3D T 2 * mapping. 2 H-DCP radical did not exhibit cytotoxicity at concentrations below 10 mM. The in vivo half-life of 2 H, 15 N-DCP in tumor tissues was 24.7 ± 2.9 min (mean ± standard deviation [SD], n = 5). The in vivo time course of the EPR signal intensity of the 2 H, 15 N-DCP radical showed a plateau of 10.2 ± 1.2 min (mean ± SD) where the EPR signal intensity remained at more than 90% of the maximum intensity. During the plateau, in vivo 3D T 2 * maps with 2 H, 15 N-DCP were obtained from tumor-bearing hind legs, with a total acquisition time of 7.5 min. EPR signals of 2 H, 15 N-DCP persisted long enough after bolus intravenous injection to conduct in vivo 3D T 2 * mapping with CW-EPR-based SPI.

  6. PKCε Increases Extracellular Elastin and Fibulin-5/DANCE in Dermal Fibroblasts.

    PubMed

    Nishizaki, Tomoyuki

    2018-01-01

    In the earlier study, the selective PKCε activator DCP-LA increased elastic fibres in the dermis of HR-1 hairless mice. As a process of elastic fibre formation, tropoelastin, an elastin monomer, is secreted into the extracellular space. Secreted tropoelastin is delivered to the microfibrils by fibulin-5/developmental arteries and neural crest epidermal growth factor-like (DANCE) and undergoes self-association. Then, tropoelastin assembles around the microfibrils, growing into elastin and elastic fibres by lysyl oxidase (LOX)- or LOX-like (LOXL)-mediated cross-linking. The present study was conducted to understand the mechanism underlying DCP-LA-induced increase in elastin/elastic fibre. Western blotting, immunocytochemistory, and real-time reverse transcription-polymerase chain reaction (RT-PCR) were carried out in cultured human dermal fibroblasts. PKCε, mammalian target of rapamycin complex (mTOR), and p70 S6 kinase (S6K) were knocked-down by transfecting each siRNA. DCP-LA increased elastin and fibulin-5/DANCE in a treatment time (6-24 h)- and a bell-shaped concentration (1 nM-1 µM)-dependent manner in the culture medium of human dermal fibroblasts. DCP-LA markedly increased elastic fibres in the extracellular space of cultured fibroblasts. DCP-LA-induced increase in extracellular elastin and fibulin-5/DANCE was abolished by a PKC inhibitor or knocking-down PKCε. DCP-LA did not affect expression of mRNAs for tropoelastin and fiblin-5/DANCE in cultured fibroblasts. DCP-LA-induced increase in extracellular elastin and fibulin-5/DANCE was not inhibited by the protein synthesis inhibitor cycloheximide or by knocking-down mTOR and S6K. DCP-LA never increased extracellular elastin in the presence of elastase, that breaks down elastin. An inhibitor of matrix metalloproteinase 9, that degrades multiple extracellular matrix components including elastin, had no effect on the basal levels and the DCP-LA-induced increase levels of extracellular elastin. The results of the present study indicate that PKCε, activated by DCP-LA, increases elastin and fibulin-5/DANCE in the extracellular space of cultured fibroblasts by the mechanism independent of transcriptional and translational modulation or inhibition of elastolysis. © 2018 The Author(s). Published by S. Karger AG, Basel.

  7. Down-regulation of Decapping Protein 2 mediates chronic nicotine exposure-induced locomotor hyperactivity in Drosophila.

    PubMed

    Ren, Jing; Sun, Jinghan; Zhang, Yunpeng; Liu, Tong; Ren, Qingzhong; Li, Yan; Guo, Aike

    2012-01-01

    Long-term tobacco use causes nicotine dependence via the regulation of a wide range of genes and is accompanied by various health problems. Studies in mammalian systems have revealed some key factors involved in the effects of nicotine, including nicotinic acetylcholine receptors (nAChRs), dopamine and other neurotransmitters. Nevertheless, the signaling pathways that link nicotine-induced molecular and behavioral modifications remain elusive. Utilizing a chronic nicotine administration paradigm, we found that adult male fruit flies exhibited locomotor hyperactivity after three consecutive days of nicotine exposure, while nicotine-naive flies did not. Strikingly, this chronic nicotine-induced locomotor hyperactivity (cNILH) was abolished in Decapping Protein 2 or 1 (Dcp2 or Dcp1) -deficient flies, while only Dcp2-deficient flies exhibited higher basal levels of locomotor activity than controls. These results indicate that Dcp2 plays a critical role in the response to chronic nicotine exposure. Moreover, the messenger RNA (mRNA) level of Dcp2 in the fly head was suppressed by chronic nicotine treatment, and up-regulation of Dcp2 expression in the nervous system blocked cNILH. These results indicate that down-regulation of Dcp2 mediates chronic nicotine-exposure-induced locomotor hyperactivity in Drosophila. The decapping proteins play a major role in mRNA degradation; however, their function in the nervous system has rarely been investigated. Our findings reveal a significant role for the mRNA decapping pathway in developing locomotor hyperactivity in response to chronic nicotine exposure and identify Dcp2 as a potential candidate for future research on nicotine dependence.

  8. Solar photocatalytic degradation of chlorophenols mixture (4-CP and 2,4-DCP): Mechanism and kinetic modelling.

    PubMed

    Abeish, Abdulbasit M; Ang, Ha Ming; Znad, Hussein

    2015-01-01

    The solar-photocatalytic degradation mechanisms and kinetics of 4-chlorophenol (4-CP) and 2,4-dichlorophenol (2,4-DCP) using TiO2 have been investigated both individually and combined. The individual solar-photocatalytic degradation of both phenolic compounds showed that the reaction rates follow pseudo-first-order reaction. During the individual photocatalytic degradation of both 4-CP and 2,4-DCP under the same condition of TiO2 (0.5 g L(-1)) and light intensities (1000 mW cm(-2)) different intermediates were detected, three compounds associated with 4-CP (hydroquinone (HQ), phenol (Ph) and 4-chlorocatechol (4-cCat)) and two compounds associated with 2,4-DCP (4-CP and Ph). The photocatalytic degradation of the combined mixture (4-CP and 2,4-DCP) was also investigated at the same conditions and different 2,4-DCP initial concentrations. The results showed that the degradation rate of 4-CP decreases when the 2,4-DCP concentration increases. Furthermore, the intermediates detected were similar to that found in the individual degradation but with high Ph concentration. Therefore, a possible reaction mechanism for degradation of this combined mixture was proposed. Moreover, a modified Langmuir-Hinshelwood (L-H) kinetic model considering all detected intermediates was developed. A good agreement between experimental and estimated results was achieved. This model can be useful for scaling-up purposes more accurately as its considering the intermediates formed, which has a significant effect on degrading the main pollutants (4-CP and 2,4-DCP).

  9. Down-Regulation of Decapping Protein 2 Mediates Chronic Nicotine Exposure-Induced Locomotor Hyperactivity in Drosophila

    PubMed Central

    Ren, Jing; Sun, Jinghan; Zhang, Yunpeng; Liu, Tong; Ren, Qingzhong; Li, Yan; Guo, Aike

    2012-01-01

    Long-term tobacco use causes nicotine dependence via the regulation of a wide range of genes and is accompanied by various health problems. Studies in mammalian systems have revealed some key factors involved in the effects of nicotine, including nicotinic acetylcholine receptors (nAChRs), dopamine and other neurotransmitters. Nevertheless, the signaling pathways that link nicotine-induced molecular and behavioral modifications remain elusive. Utilizing a chronic nicotine administration paradigm, we found that adult male fruit flies exhibited locomotor hyperactivity after three consecutive days of nicotine exposure, while nicotine-naive flies did not. Strikingly, this chronic nicotine-induced locomotor hyperactivity (cNILH) was abolished in Decapping Protein 2 or 1 (Dcp2 or Dcp1) -deficient flies, while only Dcp2-deficient flies exhibited higher basal levels of locomotor activity than controls. These results indicate that Dcp2 plays a critical role in the response to chronic nicotine exposure. Moreover, the messenger RNA (mRNA) level of Dcp2 in the fly head was suppressed by chronic nicotine treatment, and up-regulation of Dcp2 expression in the nervous system blocked cNILH. These results indicate that down-regulation of Dcp2 mediates chronic nicotine-exposure-induced locomotor hyperactivity in Drosophila. The decapping proteins play a major role in mRNA degradation; however, their function in the nervous system has rarely been investigated. Our findings reveal a significant role for the mRNA decapping pathway in developing locomotor hyperactivity in response to chronic nicotine exposure and identify Dcp2 as a potential candidate for future research on nicotine dependence. PMID:23300696

  10. Preparation of graphite dispersed copper composite with intruding graphite particles in copper plate

    NASA Astrophysics Data System (ADS)

    Noor, Abdul Muizz Mohd; Ishikawa, Yoshikazu; Yokoyama, Seiji

    2017-01-01

    In this study, it was attempted that copper-graphite composite was prepared locally on the surface of a copper plate with using a spot welding machine. Experiments were carried out with changing the compressive load, the repetition number of the compression and the electrical current in order to study the effect of them on carbon content and Vickers hardness on the copper plate surface. When the graphite was pushed into copper plate only with the compressive load, the composite was mainly hardened by the work hardening. The Vickers hardness increased linearly with an increase in the carbon content. When an electrical current was energized through the composite at the compression, the copper around the graphite particles were heated to the temperature above approximately 2100 K and melted. The graphite particles partially or entirely dissolved into the melt. The graphite particles were precipitated from the melt under solidification. In addition, this high temperature caused the improvement of wetting of copper to graphite. This high temperature caused the annealing, and reduced the Vickers hardness. Even in this case, the Vickers hardness increased with an increase in the carbon content. This resulted from the dispersion hardening.

  11. 76 FR 79675 - DCP Raptor Pipeline, LLC; Notice of Extension of Time

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-22

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR09-32-003] DCP Raptor Pipeline, LLC; Notice of Extension of Time On November 30, 2011, DCP Raptor Pipeline, LLC (Raptor) filed a... ] 61,150 (May 20, 2010). Upon consideration, notice is hereby given that an extension of time for...

  12. Waveguide module comprising a first plate with a waveguide channel and a second plate with a raised portion in which a sealing layer is forced into the waveguide channel by the raised portion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strassner, II, Bernd H.; Liedtke, Richard; McDonald, Jacob Jeremiah

    The various technologies presented herein relate to utilizing a sealing layer of malleable material to seal gaps, etc., at a joint between edges of a waveguide channel formed in a first plate and a surface of a clamping plate. A compression pad is included in the surface of the clamping plate and is dimensioned such that the upper surface of the pad is less than the area of the waveguide channel opening on the first plate. The sealing layer is placed between the waveguide plate and the clamping plate, and during assembly of the waveguide module, the compression pad deformsmore » a portion of the sealing layer such that it ingresses into the waveguide channel opening. Deformation of the sealing layer results in the gaps, etc., to be filled, improving the operational integrity of the joint.« less

  13. [Characteristic of the removal of 2,4-dichlorophenol by biological activated carbon].

    PubMed

    Liu, Hong; Li, An-jie; Quan, Xiang-chun; Kong, Xiang-hui; Yun, Ying

    2004-11-01

    The adsorption characteristics and kinetics of 2,4-Dichlorophenol (2,4-DCP) by biological activated carbon (BAC) was studied through contrast experiments with conventional activated sludge alone or quartz as the carrier. The advantage and disadvantage of removing 2,4-DCP using BAC and the mechanism of this process were investigated. The results show that the method of removing 2,4-DCP by BAC is applicable in practices, and the process of BAC demonstrates high removal rate than the process of suspended activated sludge and biofilm with quartz as the carrier. In addition, the BAC process showed high resistance to shock loadings, therefore, it is suitable to be utilized at high organic loading and under long-term operation. In BAC-system, activated carbon could not only adsorb 2,4-DCP but also oxidized 2,4-DCP.

  14. Compression failure mechanisms of uni-ply composite plates with a circular cutout

    NASA Technical Reports Server (NTRS)

    Khamseh, A. R.; Waas, A. M.

    1992-01-01

    The effect of circular-hole size on the failure mode of uniply graphite-epoxy composite plates is investigated experimentally and analytically for uniaxial compressive loading. The test specimens are sandwiched between polyetherimide plastic for nondestructive evaluations of the uniply failure mechanisms associated with a range of hole sizes. Finite-element modeling based on classical lamination theory is conducted for the corresponding materials and geometries to reproduce the experimental results analytically. The type of compressive failure is found to be a function of hole size, with fiber buckling/kinking at the hole being the dominant failure mechanism for hole diam/plate width ratios exceeding 0.062. The results of the finite-element analysis supported the experimental data for these failure mechanisms and for those corresponding to smaller hole sizes.

  15. Electrochemical properties of the erbium-chitosan-fluorine-modified PbO2 electrode for the degradation of 2,4-dichlorophenol in aqueous solution.

    PubMed

    Wang, Ying; Shen, Zhenyao; Li, Yang; Niu, Junfeng

    2010-05-01

    The erbium (Er)-chitosan-fluorine (F) modified PbO(2) electrode was prepared by electrodeposition method, and its use for adsorption and electrochemical degradation of 2,4-dichlorophenol (2,4-DCP) in aqueous solution was compared with F-PbO(2) and Er-F-PbO(2) electrodes in a batch experiment. The electrodes were characterized by scanning electron microscopy, X-ray diffraction and cyclic voltammetry. Degradation of 2,4-DCP depending on Er and chitosan contents was discussed. The results showed that Er(2)O(3) and chitosan were scattered between the prevailing crystal structure of beta-PbO(2) and thus decreased the internal stress of PbO(2) film. Prior to each electrolysis, the modified PbO(2) anode was first pre-saturated with 2,4-DCP solution for 360 min to preclude the 2,4-DCP decrease due to adsorption. Among the electrodes examined in our study, the highest adsorption and electrochemical degradation for 2,4-DCP and TOC removals that are due to oxidation and adsorption of the organic products onto the chitosan was observed on Er-chitosan-F-PbO(2) electrode. At an applied current density of 5 mAcm(-2), the removal percentages of 2,4-DCP and TOC (solution volume: 180 mL, initial 2,4-DCP concentration: 90 mgL(-1)) were 95% after 120 min and 53% after 360 min, respectively. At Er amount of 10mM in the precursor coating solution, the degradation and mineralization removal for 2,4-DCP on the Er-F-PbO(2) electrode reached a maximum. At chitosan amount of 5 gL(-1), the highest TOC removal on the Er-chitosan-F-PbO(2) electrode was observed. Intermediates mainly including aliphatic carboxylic acids were examined and a possible degradation pathway for 2,4-DCP in aqueous solution involving dechlorination and hydroxylation reactions was proposed. Copyright 2010 Elsevier Ltd. All rights reserved.

  16. A method of vehicle license plate recognition based on PCANet and compressive sensing

    NASA Astrophysics Data System (ADS)

    Ye, Xianyi; Min, Feng

    2018-03-01

    The manual feature extraction of the traditional method for vehicle license plates has no good robustness to change in diversity. And the high feature dimension that is extracted with Principal Component Analysis Network (PCANet) leads to low classification efficiency. For solving these problems, a method of vehicle license plate recognition based on PCANet and compressive sensing is proposed. First, PCANet is used to extract the feature from the images of characters. And then, the sparse measurement matrix which is a very sparse matrix and consistent with Restricted Isometry Property (RIP) condition of the compressed sensing is used to reduce the dimensions of extracted features. Finally, the Support Vector Machine (SVM) is used to train and recognize the features whose dimension has been reduced. Experimental results demonstrate that the proposed method has better performance than Convolutional Neural Network (CNN) in the recognition and time. Compared with no compression sensing, the proposed method has lower feature dimension for the increase of efficiency.

  17. Enhanced tolerance and remediation to mixed contaminates of PCBs and 2,4-DCP by transgenic alfalfa plants expressing the 2,3-dihydroxybiphenyl-1,2-dioxygenase.

    PubMed

    Wang, Yan; Ren, Hejun; Pan, Hongyu; Liu, Jinliang; Zhang, Lanying

    2015-04-09

    Polychlorinated biphenyls (PCBs) and 2,4-dichlorophenol (2,4-DCP) generally led to mixed contamination of soils as a result of commercial and agricultural activities. Their accumulation in the environment poses great risks to human and animal health. Therefore, the effective strategies for disposal of these pollutants are urgently needed. In this study, genetic engineering to enhance PCBs/2,4-DCP phytoremediation is a focus. We cloned the 2,3-dihydroxybiphenyl-1,2-dioxygenase (BphC.B) from a soil metagenomic library, which is the key enzyme of aerobic catabolism of a variety of aromatic compounds, and then it was expressed in alfalfa driven by CaMV 35S promoter using Agrobacterium-mediated transformation. Transgenic line BB11 was selected out through PCR, Western blot analysis and enzyme activity assays. Its disposal and tolerance to both PCBs and 2,4-DCP were examined. The tolerance capability of transgenic line BB11 towards complex contaminants of PCBs/2,4-DCP significantly increased compared with non-transgenic plants. Strong dissipation of PCBs and high removal efficiency of 2,4-DCP were exhibited in a short time. It was confirmed expressing BphC.B would be a feasible strategy to help achieving phytoremediation in mixed contaminated soils with PCBs and 2,4-DCP. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. The Effect of Viscosity of a Fluid on the Frequency Response of a Viscoelastic Plate Loaded by This Fluid

    NASA Astrophysics Data System (ADS)

    Zamanov, A. D.; Ismailov, M. I.; Akbarov, S. D.

    2018-03-01

    A hydroviscoelastic system consisting of a viscoelastic plate and a half-plane filled with a viscous fluid is considered. The effect of viscosity of the fluid on the frequency response of the system and its dependence on the rheological parameters of plate material are estimated. The problem on forced vibrations of the system in the plane strain state is investigated using the exact equations of viscoelastodynamics for describing the motion of the plate and linearized Navier-Stokes equations for describing the flow of the fluid. The results found in the cases of nonviscous compressible and Newtonian compressible viscous fluids are compared.

  19. Biomechanical performance of rigid compared to dynamic anterior cervical plating: analysis of adjacent upper and lower level compressive forces.

    PubMed

    Connor, David E; Shamieh, Khader Samer; Ogden, Alan L; Mukherjee, Debi P; Sin, Anthony; Nanda, Anil

    2012-12-01

    Dynamic anterior cervical plating is well established as a means of enhancing graft loading and subsequent arthrodesis. Current concerns center on the degree of adjacent-level stress induced by these systems. The aim of this study was to evaluate and compare the load transferred to adjacent levels for single-level anterior cervical discectomy and fusion utilizing rigid compared to dynamic anterior plating systems. Nine cadaveric adult human cervical spine specimens were subjected to range-of-motion testing prior to and following C5-C6 anterior cervical discectomy and fusion procedures. Interbody grafting was performed with human fibula tissue. Nondestructive biomechanical testing included flexion/extension and lateral bending loading modes. A constant displacement of 5mm was applied in each direction and the applied load was measured in newtons (N). Specimens were tested in the following order: intact, following discectomy, after rigid plating, then after dynamic plating. Adjacent level (C4-C5 [L(S)] and C6-C7 [L(I)]) compressive forces were measured using low profile load cells inserted into each disc space. The measured load values for plating systems were then normalized using values measured for the intact specimens. Mean loads transferred to L(S) and L(I) during forced flexion in specimens with rigid plating were 23.47 N and 8.76 N, respectively; while the corresponding values in specimens with dynamic plating were 18.55 N and 1.03 N, respectively. Dynamic plating yielded no significant change at L(I) and a 21.0% decrease in load at L(S) when compared with rigid plating, although the difference was not significant. The observed trend suggests that dynamic plating may diminish superior adjacent level compressive stresses. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. 76 FR 76711 - DCP Raptor Pipeline, LLC; Notice of Motion for Extension of Rate Case Filing Deadline

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-08

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR09-32-003] DCP Raptor..., 2011, DCP Raptor Pipeline, LLC (Raptor) filed a request for an extension consistent with the Commission... pipelines to extend the cycle for such reviews from three to five years.\\1\\ Therefore, Raptor requests that...

  1. Stress relaxation of swine growth plate in semi-confined compression: depth dependent tissue deformational behavior versus extracellular matrix composition and collagen fiber organization.

    PubMed

    Amini, Samira; Mortazavi, Farhad; Sun, Jun; Levesque, Martin; Hoemann, Caroline D; Villemure, Isabelle

    2013-01-01

    Mechanical environment is one of the regulating factors involved in the process of longitudinal bone growth. Non-physiological compressive loading can lead to infantile and juvenile musculoskeletal deformities particularly during growth spurt. We hypothesized that tissue mechanical behavior in sub-regions (reserve, proliferative and hypertrophic zones) of the growth plate is related to its collagen and proteoglycan content as well as its collagen fiber orientation. To characterize the strain distribution through growth plate thickness and to evaluate biochemical content and collagen fiber organization of the three histological zones of growth plate tissue. Distal ulnar growth plate samples (N = 29) from 4-week old pigs were analyzed histologically for collagen fiber organization (N = 7) or average zonal thickness (N = 8), or trimmed into the three average zones, based on the estimated thickness of each histological zone, for biochemical analysis of water, collagen and glycosaminoglycan content (N = 7). Other samples (N = 7) were tested in semi-confined compression under 10% compressive strain. Digital images of the fluorescently labeled nuclei were concomitantly acquired by confocal microscopy before loading and after tissue relaxation. Strain fields were subsequently calculated using a custom-designed 2D digital image correlation algorithm. Depth-dependent compressive strain patterns and collagen content were observed. The proliferative and hypertrophic zone developed the highest axial and transverse strains, respectively, under compression compared to the reserve zone, in which the lowest axial and transverse strains arose. The collagen content per wet mass was significantly lower in the proliferative and hypertrophic zones compared to the reserve zone, and all three zones had similar glycosaminoglycan and water content.Polarized light microscopy showed that collagen fibers were mainly organized horizontally in the reserve zone and vertically aligned with the growth direction in the proliferative and hypertrophic zones. Higher strains were developed in growth plate areas (proliferative and hypertrophic) composed of lower collagen content and of vertical collagen fiber organization. The stiffer reserve zone, with its higher collagen content and collagen fibers oriented to restrain lateral expansion under compression, could play a greater role of mechanical support compared to the proliferative and hypertrophic zones, which could be more susceptible to be involved in an abnormal growth process.

  2. Evaluation of a Diabetes Coach Program Aimed to Improve the Care of Children and Youth With Type 1 Diabetes and With Compromised Control.

    PubMed

    Luca, Paola; Haugrud, Bodiel; Husband, Allison; Dawrant, Jonathan; Pacaud, Danièle

    2018-01-31

    To evaluate the impact of the Diabetes Coach Program (DCP) on glycated hemoglobin (A1C) levels in youth with type 1 diabetes. The youth were referred to and participated in the DCP between October 2011 and May 2016. The Diabetes Coach visited families in their homes every 1 to 2 weeks and updated patients' diabetes teams regularly. A1C levels before the DCP were compared with A1C levels during and after discharge from the DCP. Six participating families completed satisfaction surveys via telephone. The DCP included 23 participants (43% male; median age, 11 years; range, 8.8 to 14.5 years); median duration of type 1 diabetes, 1.7 years (range, 0.1 to 6.3 years); median time in the DCP, 1.5 years (range, 0.2 to 2.5 years). During involvement in the program, median A1C levels decreased from baselines of 11.1% (range, 8.9% to 15.3%) to 10.2% (range, 7.6% to 12.4%) (p=0.0028). For 11 of 13 patients discharged from the DCP, the most recent median A1C levels, 11.2% (range, 9.1% to 13.6%), an average of 2.4 years later, were not different from the initial A1C levels (p=0.85). Family feedback was overwhelmingly positive. Participation in the DCP decreased A1C values in pediatric patients; however, the levels were not sustained after visits stopped. Pediatric health coaches may play an important role in the management of type 1 diabetes, but further research is needed to explore their benefits and how positive effects can be sustained. Copyright © 2018 Diabetes Canada. Published by Elsevier Inc. All rights reserved.

  3. Digestibility, productive performance, and egg quality of laying hens as affected by dried cassava pulp replacement with corn and enzyme supplementation.

    PubMed

    Khempaka, Sutisa; Maliwan, Prapot; Okrathok, Supattra; Molee, Wittawat

    2018-02-24

    Two experiments were conducted to investigate the potential use of dried cassava pulp (DCP) supplemented with enzymes as an alternative feed ingredient in laying hen diets. In experiment 1, 45 laying hens (Isa Brown) aged 45 weeks were placed in individual cages to measure nutrient digestibility for 10 days. Nine dietary treatments were control and DCP as a replacement for corn at 20, 25, 30, and 35% supplemented with mixed enzymes (cellulase, glucanase, and xylanase) at 0.10 and 0.15%. Results showed that the use of DCP at 20-35% added with mixed enzymes had no negative effects on dry matter digestibility, while organic matter digestibility and nitrogen retention decreased with increased DCP up to 30-35% in diets. Both enzyme levels (0.10 and 0.15%) showed similar results on nutrient digestibility and retention. In experiment 2, a total of 336 laying hens aged 32 weeks were randomly allocated to seven dietary treatments (control and DCP-substituted diets at 20, 25, and 30%) supplemented with mixed enzymes (0.10 and 0.15%). Diets incorporated with 20-30% of DCP and supplemented with mixed enzymes at both levels had no significant effects on egg production, egg weight, feed intake, egg mass, feed conversion ratio, protein efficiency ratio, or egg quality, except for egg yolk color being decreased with an increase of DCP in diets (P < 0.05). In conclusion, it is suggested that DCP supplemented with enzymes can be used as an energy source in laying hen diets up to 30% without showing negative effects on nutrient digestibility, productive performance, or egg quality.

  4. Elastic plate flexure above mantle plumes explains the upstream offset of volcanic activity at la Réunion and Hawaii

    NASA Astrophysics Data System (ADS)

    Gerbault, Muriel; Fontaine, Fabrice; Rabinowicz, Michel; Bystricky, Micha

    2017-04-01

    Surface volcanism at la Réunion and Hawaii occurs with an offset of 150-180 km upstream to the plume axis with respect to the plate motion. This striking observation raises questions about the forcing of plume-lithosphere thermo-mechanical interactions on melt trajectories beneath these islands. Based on visco-elasto-plastic numerical models handled at kilometric resolution, we propose to explain this offset by the development of compressional stresses at the base of the lithosphere, that result from elastic plate bending above the upward load exerted by the plume head. This horizontal compression adopts a disc shape centered around the plume axis, 20 km thick and 150 km in radius, at 50-70 km depth where the temperature varies from 600°C to 750°C. It lasts for 5 to 10 My in an oceanic plate of age greater than 70 My, a timing that is controlled by the visco-elastic relaxation time at 50-70 km depth. This period of time exceeds the time during which both the Somalian/East-African and Pacific plates drift over the Reunion and Hawaii plumes, respectively, thus rendering this basal compression a persistent feature. It is inferred that the buoyant melts percolating in the plume head pond below this zone of compression and eventually spread laterally until the most compressive principal elastic stresses reverse to the vertical, i.e., 150 km away from the plume head. There, melts propagate through dikes upwards to 35 km depth, where the plate curvature reverses and ambient compression diminishes. This 30-35 km depth may thus host magmatic reservoirs where melts pond, until further differentiation can relaunch ascension up to the surface and form a volcanic edifice. In a second stage, as the volcano grows because of melt accumulation at the top of the plate, the lithosphere is flexed downwards, inducing extra tensile stress at 30-35 km depth and compression at 15 km depth. It implies that now the melts pond at 15 km and form another magmatic reservoir lying just underneath the crust. These two processes explain the ponding of primary (shield) melts at 35 km and 15 km depths as partialy recorded below La Reunion, Mauritius or Hawaii volcanoes with seismic tomography.

  5. Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis

    PubMed Central

    Liu, Da

    2017-01-01

    In this study, we developed and validated a refined three-dimensional finite element model of middle femoral comminuted fracture to compare the biomechanical stability after two kinds of plate fixation: a newly designed assembly locking compression plate (NALCP) and a locking compression plate (LCP). CT data of a male volunteer was converted to middle femoral comminuted fracture finite element analysis model. The fracture was fixated by NALCP and LCP. Stress distributions were observed. Under slow walking load and torsion load, the stress distribution tendency of the two plates was roughly uniform. The anterolateral femur was the tension stress area, and the bone block shifted toward the anterolateral femur. Maximum stress was found on the lateral border of the number 5 countersink of the plate. Under a slow walking load, the NALCP maximum stress was 2.160e+03 MPa and the LCP was 8.561e+02 MPa. Under torsion load, the NALCP maximum stress was 2.260e+03 MPa and the LCP was 6.813e+02 MPa. Based on those results of finite element analysis, the NALCP can provide adequate mechanical stability for comminuted fractures, which would help fixate the bone block and promote bone healing. PMID:29065654

  6. [Arthrodesis of the shoulder. A new and soft-tissue-sparing technique with a deep locking plate in the supraspinatus fossa].

    PubMed

    Klonz, A; Habermeyer, P

    2007-10-01

    Arthrodesis of the glenohumeral joint is a difficult intervention that involves a relatively high probability of complications. A stable internal fixation and secure consolidation is required. The operation needs to achieve several conditions: thorough denudation of the cartilage and partial decortication of the subchondral bone; good congruence of the corresponding surfaces; compression of the gap by tension screws and lasting stability. For increased primary stability a neutralizing plate is generally used as well as a compression screw. Up to now, the plate has usually been applied starting from the scapular spine and extending across the acromial corner to the humeral shaft. A wide exposure is needed for this procedure; the plate is difficult to shape during the operation and often causes some discomfort because it protrudes at the acromial corner. We present an alternative position of the plate in the supraspinatus fossa, where we have sited a 4.5 mm LCP locking plate (Synthes). The implant is inserted under the acromion, does not cause any discomfort at the acromial corner, and is far easier to shape. When it is used in association with a transarticular compressive screw, the technique results in a very stable situation, which allows physiotherapy from the first day after surgery onward.

  7. Non-contact ultrasonic gas flow metering using air-coupled leaky Lamb waves.

    PubMed

    Fan, Zichuan; Jiang, Wentao; Wright, William M D

    2018-04-23

    This paper describes a completely non-contact ultrasonic method of gas flow metering using air-coupled leaky Lamb waves. To show proof of principle, a simplified representation of gas flow in a duct, comprising two separated thin isotropic plates with a gas flowing between them, has been modelled and investigated experimentally. An airborne compression wave emitted from an air-coupled capacitive ultrasonic transducer excited a leaky Lamb wave in the first plate in a non-contact manner. The leakage of this Lamb wave crossed the gas flow at an angle between the two plates as a compression wave, and excited a leaky Lamb wave in the second plate. An air-coupled capacitive ultrasonic transducer on the opposite side of this second plate then detected the airborne compression wave leakage from the second Lamb wave. As the gas flow shifted the wave field between the two plates, the point of Lamb wave excitation in the second plate was displaced in proportion to the gas flow rate. Two such measurements, in opposite directions, formed a completely non-contact contra-propagating Lamb wave flow meter, allowing measurement of the flow velocity between the plates. A COMSOL Multiphysics® model was used to visualize the wave fields, and accurately predicted the time differences that were then measured experimentally. Experiments using different Lamb wave frequencies and plate materials were also similarly verified. This entirely non-contact airborne approach to Lamb wave flow metering could be applied in place of clamp-on techniques in thin-walled ducts or pipes. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Biomechanical characteristics of fixation methods for floating pubic symphysis.

    PubMed

    Song, Wenhao; Zhou, Dongsheng; He, Yu

    2017-03-07

    Floating pubic symphysis (FPS) is a relatively rare injury caused by high-energy mechanisms. There are several fixation methods used to treat FPS, including external fixation, subcutaneous fixation, internal fixation, and percutaneous cannulated screw fixation. To choose the appropriate fixation, it is necessary to study the biomechanical performance of these different methods. The goal of this study was to compare the biomechanical characteristics of six methods by finite element analysis. A three-dimensional finite element model of FPS was simulated. Six methods were used in the FPS model, including external fixation (Ext), subcutaneous rod fixation (Sub-rod), subcutaneous plate fixation (Sub-plate), superior pectineal plate fixation (Int-sup), infrapectineal plate fixation (Int-ifa), and cannulated screw fixation (Int-scr). Compressive and rotational loads were then applied in all models. Biomechanical characteristics that were recorded and analyzed included construct stiffness, micromotion of the fracture gaps, von Mises stress, and stress distribution. The construct stiffness of the anterior pelvic ring was decreased dramatically when FPS occurred. Compressive stiffness was restored by the three internal fixation and Sub-rod methods. Unfortunately, rotational stiffness was not restored satisfactorily by the six methods. For micromotion of the fracture gaps, the displacement was reduced significantly by the Int-sup and Int-ifa methods under compression. The internal fixation methods and Sub-plate method performed well under rotation. The maximum von Mises stress of the implants was not large. For the plate-screw system, the maximum von Mises stress occurred over the region of the fracture and plate-screw joints. The maximum von Mises stress appeared on the rod-screw and screw-bone interfaces for the rod-screw system. The present study showed the biomechanical advantages of internal fixation methods for FPS from a finite element view. Superior stabilization of the anterior pelvic ring and fracture gaps was obtained by internal fixation. Subcutaneous fixation had satisfactory outcomes as well. Sub-rod fixation offered good anti-compression, while the Sub-plate fixation provided favorable anti-rotational capacity.

  9. Chondron curvature mapping in growth plate cartilage under compressive loading.

    PubMed

    Vendra, Bhavya B; Roan, Esra; Williams, John L

    2018-05-18

    The physis, or growth plate, is a layer of cartilage responsible for long bone growth. It is organized into reserve, proliferative and hypertrophic zones. Unlike the reserve zone where chondrocytes are randomly arranged, either singly or in pairs, the proliferative and hypertrophic chondrocytes are arranged within tubular structures called chondrons. In previous studies, the strain patterns within the compressed growth plate have been reported to be nonuniform and inhomogeneous, with an apparent random pattern in compressive strains and a localized appearance of tensile strains. In this study we measured structural deformations along the entire lengths of chondrons when the physis was subjected to physiological (20%) and hyper-physiological (30% and 40%) levels of compression. This provided a means to interpret the apparent random strain patterns seen in texture correlation maps in terms of bending deformations of chondron structures and provided a physical explanation for the inhomogeneous and nonuniform strain patterns reported in previous studies. We observed relatively large bending deformations (kinking) of the chondron structures at the interface of the reserve and proliferative zones during compression. Bending in this region may induce dividing cells to align longitudinally to maintain column formation and drive longitudinal growth. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. 78 FR 47313 - DCP Midstream, LP; Notice of Intent To Prepare an Environmental Assessment for the Proposed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-05

    ... Commission (FERC or Commission) will prepare an environmental assessment (EA) that will discuss the... by DCP Midstream, LP (DCP) in Weld County, Colorado. The Commission will use this EA in its decision... to evaluate in the EA. Please note that the scoping period will close on August 28, 2013. This notice...

  11. GENOTOXICITY OF 1,3-DICHLOROPROPANE, 2,2-DICHLOROPROPANE, AND L,1-DICHLOROPROPENE IN SALMONELLA AND E. COLI PROPHAGE-INDUCTION ASSAYS

    EPA Science Inventory

    Genotoxicity of 1,3-Dichloropropane, 2,2-Dichloropropane, and 1,1-Dichloropropene in
    Salmonella and E. coli Prophage-Induction Assays

    1,3-Dichloropropane (1,3-DCP), 2,2-dichloropropane (2,2-DCP), and 1,1- dichloropropene (I,I-DCP) have been detected in ground water i...

  12. A Simplified Model for the Effect of Weld-Induced Residual Stresses on the Axial Ultimate Strength of Stiffened Plates

    NASA Astrophysics Data System (ADS)

    Chen, Bai-Qiao; Guedes Soares, C.

    2018-03-01

    The present work investigates the compressive axial ultimate strength of fillet-welded steel-plated ship structures subjected to uniaxial compression, in which the residual stresses in the welded plates are calculated by a thermo-elasto-plastic finite element analysis that is used to fit an idealized model of residual stress distribution. The numerical results of ultimate strength based on the simplified model of residual stress show good agreement with those of various methods including the International Association of Classification Societies (IACS) Common Structural Rules (CSR), leading to the conclusion that the simplified model can be effectively used to represent the distribution of residual stresses in steel-plated structures in a wide range of engineering applications. It is concluded that the widths of the tension zones in the welded plates have a quasi-linear behavior with respect to the plate slenderness. The effect of residual stress on the axial strength of the stiffened plate is analyzed and discussed.

  13. Identification and environmental distribution of dcpA encoding the 1,2-dichloropropane-to-propene reductive dehalogenase in organohalide-respiring Chloroflexi

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Padilla-Crespo, Elizabeth; Yan, Jun; Swift, Cynthia M

    2014-01-01

    Dehalococcoides mccartyi (Dhc) strains KS and RC grow with 1,2-dichloropropane (1,2-D) as an electron acceptor in enrichment cultures derived from hydrocarbon-contaminated and pristine river sediments, respectively. Transcription, expression, enzymatic and PCR analyses implicated the reductive dehalogenase gene dcpA in 1,2-D dichloroelimination to propene and inorganic chloride. Quantitative real-time PCR (qPCR) analyses demonstrated Dhc cell increase during growth with 1,2-D and suggested that both Dhc strains carried a single dcpA gene copy per genome. Dhc strain RC and strain KS produced 1.8 0.1 x 107 and 1.4 0.5 x 107 cells per mole of propene formed, respectively. The dcpA gene wasmore » identified in 1,2-D-to-propene-dechlorinating microcosms established with sediment samples collected from different geographical locations in Europe and North and South America. Clone library analysis revealed two distinct dcpA phylogenetic clusters, both of which the dcpA gene-targeted qPCR assay captured, suggesting the qPCR assay is useful for site assessment and bioremediation monitoring at 1,2-D-contaminated sites.« less

  14. Loads and Deformations of Buckled Rectangular Plates. Degree awarded by Virginia Polytechnic Inst., Jun. 1958

    NASA Technical Reports Server (NTRS)

    Stein, Manuel

    1959-01-01

    The nonlinear large-deflection equations of von Karman for plates are converted into a set of linear equations by expanding the displacements Into a power series in terms of an arbitrary parameter. The postbuckling behavior of simply supported rectangular plates subjected to longitudinal compression and subject to a uniform temperature rise is investigated in detail by solving the first few of the equations. Experimental data are presented for the compression problem. Comparisons are made for total shortening and local strains and deflections which indicate good agreement between experimental and theoretical results.

  15. A prospective, randomised trial comparing closed intramedullary nailing with percutaneous plating in the treatment of distal metaphyseal fractures of the tibia.

    PubMed

    Guo, J J; Tang, N; Yang, H L; Tang, T S

    2010-07-01

    We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients' age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware. We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p < 0.001, and 97.9 vs 81.2 minutes, p < 0.001, respectively).After one year, all the fractures had united. Patients who had intramedullary nailing had a higher mean pain score (40 = no pain, 0 = severe pain), [corrected] but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed. We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with these fractures.

  16. [Advanced bone graft combined with locking compression plate for the treatment of middle and distal tibia nonunion].

    PubMed

    Zhao, Xue; Wang, Pan-feng; Zhang, Yun-tong; Zhang, Chun-cai; Xu, Shuo-gui; Zhang, Xin

    2014-12-01

    To explore methods of treating middle and distal tibia nonunion with the treatment of advanced bone graft combined with locking compression plate. From January 2011 to December 2012, 12 patients with middle and distal tibia nonunion were treated with advanced bone graft combined with locking compression plate. Among patients, there were 8 males and 4 females aged from 20 to 69 with an average of 47 years old. The time from first injuries to bone nonunion was from 9 months to 5 years, avergaed 19 months. Four cases were treated with external fixation, 6 cases were treated with plate fixation, 2 cases of 12 patients occurred broken of plate and nail. Eleven patients were non-infective bone nonunion and 1 patient was infective bone nonunion. Preoperative X-ray and CT showed all patients had sequestration and formation of ossified bone with different degrees. Operative time, blood loss, wound healing were observed, fracture healing time was evaluated by postoperative X-ray. Johner-Wruhs scoring standards was used to evaluate ankle joint function after operation at 10 months. Operative time ranged from 90 to 185 min with an average of (125.00±20.15) min; blood loss ranged from 225 to 750 ml with an average of (415.00±120.00) ml. All patients were followed up from 10 months to 2.5 years with an average of 1.5 years. Postoperative X-ray showed bone union was formed around fracture after operation at 4 months in all patients, 3 cases obtained bone healing within 6 months after operation, 9 cases obtained from 8 to 12 months. No infection, injury of nerve and vessles, and broken of plate and nail were ocurred. According to Johner-Wruhs scoring at 10 months after operation, 10 cases obtained excellent results, 1 good and 1 moderate. Advanced bone graft combined with locking compression plate, which can build fracture multi-point supporting based on full compression of bone nonunion to get effective fixation, is an effective method in treating middle and distal tibia nonunion.

  17. The use of used automobile tyres in a partitioning bioreactor for the biodegradation of xenobiotic mixtures.

    PubMed

    Tomeia, M Concetta; Angeluccia, Domenica Mosca; Daugulis, Andrew J

    2014-01-01

    Waste tyres were utilized as the sorption phase in a two-phase partitioning bioreactor (TPPB) for the biodegradation of a binary mixture of 2,4-dichlorophenol (DCP) and 4-nitrophenol (4NP). These compounds are extensively used in the chemical industry and are found in many industrial effluents. Although both compounds are toxic and are on the EPA list of priority pollutants, a higher inhibitory effect on microorganisms is exerted by DCP, and our experimental tests were focused on strategies to reduce its negative impact on microbial activity. Sorption/desorption tests for the DCP-4NP mixture were first performed to verify the related uptake/release rates by the tyres, which showed that the tyres had a higher capacity for DCP uptake and practically no affinity for 4NP. An acclimatized mixed culture was then utilized in a sequencing batch reactor (SBR) operated in conventional and two-phase mode. For the binary DCP-4NP mixture a significant reduction in DCP toxicity, and a concomitant enhancement in substrate removal efficiency (up to 83%for DCP and approximate 100% for 4NP) were clearly seen for the TPPB operated with 10% and 15% v/v tyres, for influent concentrations up to 180 mg/L, with practically negligible biodegradation in the conventional single phase reactor. The long-term utilization of tyres was confirmed at an influent loading of 180 mg/L with a test performed over 20 work cycles showing an improvement of the removal performance for both compounds.

  18. Observation of the initiation and progression of damage in compressively loaded composite plates containing a cutout

    NASA Technical Reports Server (NTRS)

    Waas, A.; Babcock, C., Jr.

    1986-01-01

    A series of experiments was carried out to determine the mechanism of failure in compressively loaded laminated plates with a circular cutout. Real time holographic interferometry and photomicrography are used to observe the progression of failure. These observations together with post experiment plate sectioning and deplying for interior damage observation provide useful information for modelling the failure process. It is revealed that the failure is initiated as a localised instability in the zero layers, at the hole surface. With increasing load extensive delamination cracking is observed. The progression of failure is by growth of these delaminations induced by delamination buckling. Upon reaching a critical state, catastrophic failure of the plate is observed. The levels of applied load and the rate at which these events occur depend on the plate stacking sequence.

  19. On optimization of a composite bone plate using the selective stress shielding approach.

    PubMed

    Samiezadeh, Saeid; Tavakkoli Avval, Pouria; Fawaz, Zouheir; Bougherara, Habiba

    2015-02-01

    Bone fracture plates are used to stabilize fractures while allowing for adequate compressive force on the fracture ends. Yet the high stiffness of conventional bone plates significantly reduces compression at the fracture site, and can lead to subsequent bone loss upon healing. Fibre-reinforced composite bone plates have been introduced to address this drawback. However, no studies have optimized their configurations to fulfill the requirements of proper healing. In the present study, classical laminate theory and the finite element method were employed for optimization of a composite bone plate. A hybrid composite made of carbon fibre/epoxy with a flax/epoxy core, which was introduced previously, was optimized by varying the laminate stacking sequence and the contribution of each material, in order to minimize the axial stiffness and maximize the torsional stiffness for a given range of bending stiffness. The initial 14×4(14) possible configurations were reduced to 13 after applying various design criteria. A comprehensive finite element model, validated against a previous experimental study, was used to evaluate the mechanical performance of each composite configuration in terms of its fracture stability, load sharing, and strength in transverse and oblique Vancouver B1 fracture configurations at immediately post-operative, post-operative, and healed bone stages. It was found that a carbon fibre/epoxy plate with an axial stiffness of 4.6 MN, and bending and torsional stiffness of 13 and 14 N·m(2), respectively, showed an overall superiority compared with other laminate configurations. It increased the compressive force at the fracture site up to 14% when compared to a conventional metallic plate, and maintained fracture stability by ensuring the fracture fragments' relative motions were comparable to those found during metallic plate fixation. The healed stage results revealed that implantation of the titanium plate caused a 40.3% reduction in bone stiffness, while the composite plate lowered the stiffness by 32.9% as compared to the intact femur. This study proposed a number of guidelines for the design of composite bone plates. The findings suggest that a composite bone plate could be customized to allow for moderate compressive force on the fracture ends, while remaining relatively rigid in bending and torsion and strong enough to withstand external loads when a fracture gap is present. The results indicate that the proposed composite bone plate could be a potential candidate for bone fracture plate applications. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. GENOTOXICITY OF 1,3-DICHLOROPROPANE, 2,2-DICHLOROPROPANE, AND 1,1-DICHLOROPROPENE IN SALMONELLA, THE E. COLI PROPHAGE-INDUCTION ASSAY, AND HUMAN HEPH2 CELLS

    EPA Science Inventory

    Genotoxicity of 1,3-Dichloropropane, 2,2-Dichloropropane, and 1,1-Dichloropropene in Salmonella, the E. coli Prophage-Induction Assay and Human HepG2 Cells

    1,3-Dichloropropane (1,3-DCP), 2,2-dichloropropane (2,2-DCP), and 1,1- dichloropropene ( 1,1- DCP) have been detecte...

  1. Measurement of the viscoelastic properties of the vocal folds.

    PubMed

    Wiikmann, Christian; da Silva, Marcelo Alves; Arêas, Elizabeth Pinheiro Gomes; Tsuji, Domingos Hiroshi; Sennes, Luiz Ubirajara

    2009-06-01

    Studies of the viscoelastic properties of the vocal folds are normally performed with rheometers that use parallel plates whose interplate space is usually arbitrarily assigned a fixed value. In tissues subject to variation of thickness between samples, fixed gaps could result in different compressions, compromising the comparison among them. We performed an experimental study to determine whether different compressions can lead to different results in measurements of dynamic viscosity (DV) of vocal fold samples. We measured the DV of vocal fold samples of 10 larynges of cadavers under 3 different compression levels, corresponding to 0.2, 0.5, and 10 N on an 8-mm-diameter parallel-plate rheometer. The DV directly varied with compression. We observed statistically significant differences between the results of 0.2 and 10 N (p = 0.0396) and 0.5 and 10 N (p = 0.0442). The study demonstrated that the level of compression influences the DV measure and suggests that a defined compression level should be used in rheometric studies of biological tissues.

  2. Critical Compressive Stress for Flat Rectangular Plates Supported Along All Edges and Elastically Restrained Against Rotation along the Unloaded Edges

    NASA Technical Reports Server (NTRS)

    Lundquist, Eugene E; Stowell, Elbridge Z

    1942-01-01

    A chart is presented for the values of the coefficient in the formula for the critical compressive stress at which buckling may be expected to occur in flat rectangular plates supported along all edges and, in addition, elastically restrained against rotation along the unloaded edges. The mathematical derivations of the formulas required in the construction of the chart are given.

  3. The fatigue growth of internal delaminations under compressive loading of cross-ply composite plates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pelegri, A.A.; Kardomateas, G.A.; Malik, B.U.

    1997-12-31

    This study focuses on the mode dependence of delamination growth under cyclic compressive loads in cross-ply composite plates. The model proposed makes use of an initial postbuckling solution derived from a perturbation procedure. A mode-dependent crack growth criterion is introduced. Expressions describing the fatigue crack growth are derived in terms of the distribution of the mode adjusted energy release rate. The resulting crack growth laws are numerically integrated to produce delamination growth versus number of cycles diagrams. The model does not impose any restrictive assumptions on the relative thickness of the delaminated and the base plates, although transverse shear stressmore » effects are not considered. Experimental results are presented for cross-ply graphite/epoxy specimens, and the results are compared with experimental results for unidirectional specimens. The test data are obtained for different delamination locations and for different values of applied compressive strain.« less

  4. Use of intramedullary fibular strut graft: a novel adjunct to plating in the treatment of osteoporotic humeral shaft nonunion

    PubMed Central

    Vamsi, K.; Rao, Sharath K.; Gnanadoss, James J.; Pandian, S.

    2008-01-01

    Humeral shaft fractures respond well to conservative treatment and unite without much problem. Since it is uncommon, there is not much discussion regarding the management of nonunion in the literature, and hence this is a challenge to the treating orthopaedic surgeon. Osteoporosis of the fractured bone and stiffness of the surrounding joints compounds the situation further. The Ilizarov fixator, locking compression plate, and vascularised fibular graft are viable options in this scenario but are technically demanding. We used a fibular strut graft for bridging the fracture site in order to enhance the pull-out strength of the screws of the dynamic compression plate. Six patients in the study had successful uneventful union of the fracture at the last follow-up. The fibula is easy to harvest and produces less graft site morbidity. None of the study patients needed additional iliac crest bone grafting. This is the largest reported series of patients with osteoporotic atrophic nonunion of humerus successfully treated solely using the combination of an intramedullary fibular strut graft and dynamic compression plate. PMID:18563410

  5. The beetle elytron plate: a lightweight, high-strength and buffering functional-structural bionic material.

    PubMed

    Zhang, Xiaoming; Xie, Juan; Chen, Jinxiang; Okabe, Yoji; Pan, Longcheng; Xu, Mengye

    2017-06-30

    To investigate the characteristics of compression, buffering and energy dissipation in beetle elytron plates (BEPs), compression experiments were performed on BEPs and honeycomb plates (HPs) with the same wall thickness in different core structures and using different molding methods. The results are as follows: 1) The compressive strength and energy dissipation capacity in the BEP are 2.44 and 5.0 times those in the HP, respectively, when the plates are prepared using the full integrated method (FIM). 2) The buckling stress is directly proportional to the square of the wall thickness (t). Thus, for core structures with equal wall thicknesses, although the core volume of the BEP is 42 percent greater than that of the HP, the mechanical properties of the BEP are several times higher than those of the HP. 3) It is also proven that even when the single integrated method (SIM) is used to prepare BEPs, the properties discussed above remain superior to those of HPs by a factor of several; this finding lays the foundation for accelerating the commercialization of BEPs based on modern manufacturing processes.

  6. 1,3-Dichloro-2-propanol inhibits progesterone production through the expression of steroidogenic enzymes and cAMP concentration in Leydig cells.

    PubMed

    Sun, Jianxia; Bai, Shun; Bai, Weibin; Zou, Feiyan; Zhang, Lei; Li, Guoqiang; Hu, Yunfeng; Li, Mingwei; Yan, Rian; Su, Zhijian; Huang, Yadong

    2014-07-01

    1,3-Dichloro-2-propanol (1,3-DCP) is a well-known food processing contaminant that has been shown to impede male reproductive function. However, its mechanism of action remains elusive. In this study, the effects of 1,3-DCP on progesterone production were investigated using the R2C Leydig cell model. 1,3-DCP significantly reduced cell viability from 7.48% to 97.4% at doses comprised between 0.5 and 6mM. Single cell gel/comet assays and atomic force microscopy assays showed that 1,3-DCP induced early phase cell apoptosis. In addition, 1,3-DCP significantly reduced progesterone production detected by radioimmunoassay (RIA). The results from quantitative polymerase chain reaction and western blotting demonstrated that the mRNA expression levels of steroidogenic acute regulatory protein (StAR), cytochrome P450 side-chain cleavage enzyme and 3β-hydroxysteroid dehydrogenase were significantly down-regulated in R2C cells. Particularly, the change rhythm of Star expression was highly consistent with progesterone production. Furthermore, the cyclic adenosine monophosphate (cAMP) and the mitochondrial membrane potential mediated by ROS, which are involved in regulating progesterone synthesis were also decreased in response to the 1,3-DCP treatment. Overall, the data presented here suggested that 1,3-DCP interferes with the male steroidogenic capacity mainly by down-regulating the level of cAMP and the key enzymes involved in the androgen synthesis pathway. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Stress-Shielding Effect of Nitinol Swan-Like Memory Compressive Connector on Fracture Healing of Upper Limb

    NASA Astrophysics Data System (ADS)

    Fu, Q. G.; Liu, X. W.; Xu, S. G.; Li, M.; Zhang, C. C.

    2009-08-01

    In this article, the stress-shielding effect of a Nitinol swan-like memory compressive connector (SMC) is evaluated. Patients with fracture healing of an upper limb after SMC internal fixation or stainless steel plate fixation were randomly selected and observed comparatively. With the informed consent of the SMC group, minimal cortical bone under the swan-body and swan-neck was harvested; and in the steel plate fixation group, minimal cortical bone under the steel plate and opposite side to the steel plate was also harvested for observation. Main outcome measurements were taken such as osteocyte morphology, Harversian canal histological observation under light microscope; radiographic observation of fracture healing, and computed tomography quantitative scanning of cortical bone. As a conclusion, SMC has a lesser stress-shielding effect to fixed bone than steel plate. Finally, the mechanism of the lesser stress-shielding effect of SMC is discussed.

  8. Urinary concentrations of dichlorophenol pesticides and obesity among adult participants in the U.S. National Health and Nutrition Examination Survey (NHANES) 2005-2008.

    PubMed

    Wei, Yudan; Zhu, Jianmin; Nguyen, An

    2014-03-01

    Accumulating evidence from recent studies has suggested a possible link between exposure to environmental pesticides and obesity. In this study, we assessed the potential associations between exposure to dichlorophenol pesticides and obesity in adults. Study participants aged 20-85 years were selected from the 2005 to 2006 and 2007 to 2008 U.S. National Health and Nutrition Examination Survey, and were categorized as obese and non-obese based on body mass index. Creatinine-corrected urinary concentrations of dichlorophenols were determined to assess level of exposure to environmental pesticides. Multivariate logistic regression was performed using SAS 9.3 to assess the association between 2,4-dichlorophenol (2,4-DCP) and 2,5-dichlorophenol (2,5-DCP) levels in urine and obesity with adjustment for potential confounders. Significantly higher geometric means of urinary concentrations of both 2,5-DCP (p<0.0001) and 2,4-DCP (p=0.0170) were seen in obese adults, compared to that in non-obese adults. A dose-dependent increase in the prevalence of obesity was observed in the study participants across increasing levels of urinary 2,5-DCP (p-trend<0.0001). Urinary concentrations of 2,5-DCP were significantly associated with obesity among the second (AOR: 1.47, 95% CI: 1.12, 1.93), third (AOR: 1.41, 95% CI: 1.07, 1.87), and fourth (AOR: 1.62, 95% CI: 1.21, 2.17) inter-quartiles after adjustment for age, gender, race, education, total fat intake, and physical activity. A statistically significant association was not seen between urinary 2,4-DCP and obesity. Our findings suggest a potential relationship between exposure to the fumigant insecticide paradichlorobenzene, measured as urinary concentrations of 2,5-DCP, and obesity in adults. Because we cannot rule out the possibility of reverse causality in our study, prospective studies measuring exposure during etiologically relevant periods are warranted. Copyright © 2013 Elsevier GmbH. All rights reserved.

  9. Formation of Epichlorohydrin, a Known Rodent Carcinogen, Following Oral Administration of 1,3-Dichloro-2-propanol in Rats

    PubMed Central

    2015-01-01

    The observed toxicity and carcinogenicity of 1,3-dichloro-2-propanol (DCP) in rodents is thought to be due to the formation of reactive metabolites, epichlorohydrin (ECH) and dichloroacetone (DCA). However, there is no direct evidence for the formation of these metabolites from exposure to DCP in rodents due to the challenges of measuring these reactive intermediates directly in vivo. The objective of this work was to investigate the metabolism of DCP to ECH and DCA in vivo by first developing a sensitive analytical method in a suitable biological matrix and analyzing samples from rats administered DCP. DCA reacted rapidly in vitro in rat blood, plasma, and liver homogenate, precluding its detection. Because ECH rapidly disappeared in liver homogenate, but was relatively long-lived in plasma and blood in vitro, blood was selected for analysis of this metabolite. Following a single oral dose of 50 mg/kg DCP in male or female Harlan Sprague–Dawley rats, ECH was detected in blood with a maximum concentration reached at ≤13.7 min. ECH was cleared rapidly with a half-life of ca. 33 and 48 min in males and females, respectively. Following a single oral dose of 25 mg/kg ECH in male and female rats, the elimination half-life of ECH was ca. 34 and 20 min, respectively; the oral bioavailability of ECH was low (males, 5.2%; females, 2.1%), suggesting extensive first pass metabolism of ECH following oral administration. The area under the concentration vs time curve for ECH following oral administration of DCP and intravenous administration of ECH was used to estimate the percent of the DCP dose converted to ECH in rats. On the basis of this analysis, we concluded that in male and female rats following oral administration of 50 mg/kg DCP, ≥1.26% or ≥1.78% of the administered dose was metabolized to ECH, respectively. PMID:25254956

  10. Generalized wall function and its application to compressible turbulent boundary layer over a flat plate

    NASA Astrophysics Data System (ADS)

    Liu, J.; Wu, S. P.

    2017-04-01

    Wall function boundary conditions including the effects of compressibility and heat transfer are improved for compressible turbulent boundary flows. Generalized wall function formulation at zero-pressure gradient is proposed based on coupled velocity and temperature profiles in the entire near-wall region. The parameters in the generalized wall function are well revised. The proposed boundary conditions are integrated into Navier-Stokes computational fluid dynamics code that includes the shear stress transport turbulence model. Numerical results are presented for a compressible boundary layer over a flat plate at zero-pressure gradient. Compared with experimental data, the computational results show that the generalized wall function reduces the first grid spacing in the directed normal to the wall and proves the feasibility and effectivity of the generalized wall function method.

  11. Numerical investigation of the effects of compressibility on the flutter of a cantilevered plate in an inviscid, subsonic, open flow

    NASA Astrophysics Data System (ADS)

    Colera, Manuel; Pérez-Saborid, Miguel

    2018-06-01

    We have carried out a numerical study of the influence of the upstream Mach number on the flutter of a two-dimensional, cantilevered, flexible plate subject to a subsonic, inviscid, open flow. We have assumed a linear elastic model for the plate and that the fluid flow is governed by the linearized potential theory. The fluid equations are solved with a novel frequency-domain, finite differences method to obtain the generalized aerodynamic forces as a function of the plate displacements. Then, these generalized forces are coupled to the equation of motion of the plate and an eigenvalue analysis is performed to find the flutter point. The obtained results are in good agreement with those of related theoretical and experimental studies found in the literature. To the best of our knowledge, the analysis performed here is the first self-consistent, parametric study of the influence of the compressibility on the flutter point of a two-dimensional cantilevered plate in subsonic flow.

  12. Fatigue damage prognosis of internal delamination in composite plates under cyclic compression loadings using affine arithmetic as uncertainty propagation tool

    NASA Astrophysics Data System (ADS)

    Gbaguidi, Audrey J.-M.

    Structural health monitoring (SHM) has become indispensable for reducing maintenance costs and increasing the in-service capacity of a structure. The increased use of lightweight composite materials in aircraft structures drastically increased the effects of fatigue induced damage on their critical structural components and thus the necessity to predict the remaining life of those components. Damage prognosis, one of the least investigated fields in SHM, uses the current damage state of the system to forecast its future performance by estimating the expected loading environments. A successful damage prediction model requires the integration of technologies in areas like measurements, materials science, mechanics of materials, and probability theories, but most importantly the quantification of uncertainty in all these areas. In this study, Affine Arithmetic is used as a method for incorporating the uncertainties due to the material properties into the fatigue life prognosis of composite plates subjected to cyclic compressive loadings. When loadings are compressive in nature, the composite plates undergo repeated buckling-unloading of the delaminated layer which induces mixed modes I and II states of stress at the tip of the delamination in the plates. The Kardomateas model-based prediction law is used to predict the growth of the delamination, while the integration of the effects of the uncertainties for modes I and II coefficients in the fatigue life prediction model is handled using Affine arithmetic. The Mode I and Mode II interlaminar fracture toughness and fatigue characterization of the composite plates are first experimentally studied to obtain the material coefficients and fracture toughness, respectively. Next, these obtained coefficients are used in the Kardomateas law to predict the delamination lengths in the composite plates while using Affine Arithmetic to handle their uncertainties. At last, the fatigue characterization of the composite plates during compressive-buckling loadings is experimentally studied, and the delamination lengths obtained are compared with the predicted values to check the performance of Affine Arithmetic as an uncertainty propagation tool.

  13. Comparison of two screening bioassays, based on the frog sciatic nerve and yeast cells, for the assessment of herbicide toxicity.

    PubMed

    Papaefthimiou, Chrisovalantis; Cabral, Maria de Guadalupe; Mixailidou, Christina; Viegas, Cristina A; Sá-Correia, Isabel; Theophilidis, George

    2004-05-01

    Two different test systems, one based on the isolated sciatic nerve of an amphibian and the other on a microbial eukaryote, were used for the assessment of herbicide toxicity. More specifically, we determined the deleterious effects of increasing concentrations of herbicides of different chemical classes (phenoxyacetic acids, triazines, and acetamides), and of 2,4-dichlorophenol (2,4-DCP), a degradation product of the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D), on electrophysiological parameters and the vitality of the axons of the isolated sciatic nerve of the frog (Rana ridibunda) and on the growth curve of the yeast Saccharomyces cerevisiae based on microtiter plate susceptibility assays. The no-observed-effect-concentration (NOEC), defined as the maximum concentration of the tested compound that has no effect on these biological parameters, was estimated. In spite of the different methodological approaches and biological systems compared, the NOEC values were identical and correlated with the lipophilicity of the tested compounds. The relative toxicity established here, 2,4-DCP > alachlor, metolachlor > metribuzin > 2,4-D, 2-methyl-4-chlorophenoxyacetic acid (MCPA), correlates with the toxicity indexes reported in the literature for freshwater organisms. Based on these results, we suggest that the relatively simple, rapid, and low-cost test systems examined here may be of interest as alternative or complementary tests for toxicological assessment of herbicides.

  14. Fixation of osteoporotic fractures in the upper limb with a locking compression plate.

    PubMed

    Neuhaus, V; King, J D; Jupiter, J B

    2012-01-01

    Locking Compression Plate (LCP) has the advantageous feature that screws can be locked in the plate leaving an angular stable construct. There is no need to have contact between the plate and the bone to achieve stability resulting from friction of the plate-bone-construct. Therefore the plate does not need to be contoured exactly to the bone and the healing bone's periosteal blood supply is not affected. The LCP is used as a bridging plate to gain relative stability in multi-fragmentary, diaphyseal or metaphyseal fractures. Depending on the fracture, the combination hole can also allow the LCP to achieve absolute stability similar to conventional fixation techniques. Osteoporotic fractures have significant impact on morbidity and mortality. Proximal humeral and distal radius fractures are typical examples. These osteoporotic and often comminuted fractures are ideal settings/indications for LCP utilization in the upper extremity. However, the data quality is due to mostly small study populations not so powerful. Unquestionably there has been a clear and fashionable trend to choose operative treatment for these fractures, because the angular stability allows stable fixation and early functional mobilization.

  15. Detail of interior of compressed air chamber showing top of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail of interior of compressed air chamber showing top of working chamber and tie rods that strengthen the outer shell plates of the compression chamber. - Sub Marine Explorer, Located along the beach of Isla San Telmo, Pearl Islands, Isla San Telmo, Former Panama Canal Zone, CZ

  16. A Degradome-Based Polymerase Chain Reaction to Resolve the Potential of Environmental Samples for 2,4-Dichlorophenol Biodegradation.

    PubMed

    Ibrahim, Eslam S; Kashef, Mona T; Essam, Tamer M; Ramadan, Mohammed A

    2017-12-01

    A clean way to overcome environmental pollution is biodegradation. In this perspective, at the intersection of biodegradation and metagenomics, the degradome is defined as the totality of genes related to the biodegradation of a certain compound. It includes the genetic elements from both culturable and uncultured microorganisms. The possibility of assessing the biodegradation potential of an environmental samples, using a degradome-based polymerase chain reaction, was explored. 2,4-Dichlorophenol (2,4-DCP) was chosen as a model and the use of tfdB gene as a biodegradation marker was confirmed by bioinformatics study of TfdB protein. Five primer pairs were designed for the detection of different tfdB gene families. A total of 16 environmental samples were collected from Egyptian agricultural soils and wastewaters and tested for the presence of 2,4-DCP. The biodegradation capacity of 2,4-DCP was determined, for all isolated consortia, to reach up to 350 mg/l. Metagenomic DNA was extracted directly from the soil samples while successive 2,4-DCP-degrading microbial communities were enriched, with increasing concentrations of 2,4-DCP, then their DNA was extracted. The extracted DNA was tested for the distribution of the tfdB gene using a degradome-based polymerase chain reaction. tfdB-1 and tfdB-2 were detected in 5 and 9 samples, respectively. However, the co-existence of both genes was detected only in five samples. All tfdB positive samples were capable of 2,4-DCP degradation. The developed approach of assessing the potential of different environments for degrading 2,4-DCP was successfully measured in terms of accuracy (81.25%) and specificity (100%).

  17. Acylhydrazone bond dynamic covalent polymer gel monolithic column online coupling to high-performance liquid chromatography for analysis of sulfonamides and fluorescent whitening agents in food.

    PubMed

    Zhang, Chengjiang; Luo, Xialin; Wei, Tianfu; Hu, Yufei; Li, Gongke; Zhang, Zhuomin

    2017-10-13

    A new dynamic covalent polymer (DCP) gel was well designed and constructed based on imine chemistry. Polycondensation of 4,4'-biphenyldicarboxaldehyde and 1,3,5-benzenetricarbohydrazide via Schiff-base reaction resulted in an acylhydrazone bond gel (AB-gel) DCP. AB-gel DCP had three-dimensional network of interconnected nanoparticles with hierarchically porous structure. AB-gel DCP was successfully fabricated as a monolithic column by an in-situ chemical bonding method for online enrichment and separation purpose with excellent permeability. AB-gel DCP based monolithic column showed remarkable adsorption affinity towards target analytes including sulfonamides (SAs) and fluorescent whitening agents (FWAs) due to its strong π-π affinity, hydrophobic effect and hydrogen bonding interaction. Then, AB-gel DCP based monolithic column was applied for online separation and analysis of trace SAs and FWAs in food samples coupled with high-performance liquid chromatography (HPLC). Sulfathiazole (ST) and sulfadimidine (SM2) in one positive weever sample were actually found and determined with concentrations of 273.8 and 286.3μg/kg, respectively. 2,5-Bis(5-tert-butyl-2-benzoxazolyl) thiophene (FWA184) was actually quantified in one tea infusion sample with the concentration of 268.5ng/L. The spiked experiments suggested the good recoveries in range of 74.5-110% for SAs in weever and shrimp samples with relative standard deviations (RSDs) less than 9.7% and in range of 74.0-113% for FWAs in milk and tea infusion samples with RSDs less than 9.0%. AB-gel DCP monolithic column was proved to be a promising sample preparation medium for online separation and analysis of trace analytes in food samples with complex matrices. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Fixture for environmental exposure of structural materials under compression load

    NASA Technical Reports Server (NTRS)

    Clark, R. K.; Lisagor, W. B. (Inventor)

    1983-01-01

    A device for stressing a deformable material specimen consists of top plate and a bottom plate sandwiching a guide cylinder. The specimen is positioned on the bottom plate and attached to a load piston. Force is applied through the top plate into the guide cylinder. Once the specimen is loaded, the stress is maintained by tightening tie bolt nuts.

  19. Deep Retinal Capillary Nonperfusion Is Associated With Photoreceptor Disruption in Diabetic Macular Ischemia.

    PubMed

    Scarinci, Fabio; Nesper, Peter L; Fawzi, Amani A

    2016-08-01

    To report outer retinal structural changes associated with macular capillary nonperfusion at the level of deep capillary plexus (DCP) in diabetic patients. Prospective observational cross-sectional study. The study included 14 eyes of 10 patients who were diagnosed as having diabetic retinopathy. To study the outer retina and localize areas of capillary nonperfusion at the superficial (SCP) or DCP, we used the spectral-domain optical coherence tomography (SDOCT) device (RTVue-XR Avanti; Optovue Inc, Fremont, California, USA) with split-spectrum amplitude-decorrelation angiography (SSADA) software for optical coherence tomography angiography (OCTA). Two independent masked graders (F.S. and A.A.F.) qualitatively evaluated SDOCT scans as either normal or having outer retina disruption. The angiographic images were examined to define the presence and location of capillary nonperfusion. Eight eyes showed outer retinal disruption on SDOCT that co-localized to areas of enlarged foveal avascular zone, areas of no flow between capillaries, and capillary nonperfusion of the DCP. Six eyes without outer retinal changes on SDOCT showed robust perfusion of the DCP. Using OCTA, this study shows that macular photoreceptor disruption on SDOCT in patients with diabetic retinopathy corresponds to areas of capillary nonperfusion at the level of the DCP. This is important in highlighting the contribution of the DCP to the oxygen requirements of the photoreceptors as well as the outer retina in diabetic macular ischemia. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Computer program to compute buckling loads of simply supported anisotropic plates

    NASA Technical Reports Server (NTRS)

    Chamis, C. C.

    1973-01-01

    Program handles several types of composites and several load conditions for each plate, both compressive or tensile membrane loads, and bending-stretching coupling via the concept of reduced bending rigidities. Vibration frequencies of homogeneous or layered anisotropic plates can be calculated by slightly modifying the program.

  1. Molecular Imprinted Polymer of Methacrylic Acid Functionalised β-Cyclodextrin for Selective Removal of 2,4-Dichlorophenol

    PubMed Central

    Surikumaran, Hemavathy; Mohamad, Sharifah; Sarih, Norazilawati Muhamad

    2014-01-01

    This work describes methacrylic acid functionalized β-cyclodextrin (MAA-βCD) as a novel functional monomer in the preparation of molecular imprinted polymer (MIP MAA-βCD) for the selective removal of 2,4-dichlorophenol (2,4-DCP). The polymer was characterized using Fourier Transform Infrared (FTIR) spectroscopy, Brunauer-Emmett-Teller (BET) and Field Emission Scanning Electron Microscopy (FESEM) techniques. The influence of parameters such as solution pH, contact time, temperature and initial concentrations towards removal of 2,4-DCP using MIP MAA-βCD have been evaluated. The imprinted material shows fast kinetics and the optimum pH for removal of 2,4-DCP is pH 7. Compared with the corresponding non-imprinted polymer (NIP MAA-βCD), the MIP MAA-βCD exhibited higher adsorption capacity and outstanding selectivity towards 2,4-DCP. Freundlich isotherm best fitted the adsorption equilibrium data of MIP MAA-βCD and the kinetics followed a pseudo-second-order model. The calculated thermodynamic parameters showed that adsorption of 2,4-DCP was spontaneous and exothermic under the examined conditions. PMID:24727378

  2. Evaluation of automated serum des-gamma-carboxyprothrombin (DCP) assays for detecting hepatocellular carcinoma.

    PubMed

    Choi, Jonghyeon; Park, Yongjung; Kim, Jeong-Ho; Kim, Hyon-Suk

    2011-12-01

    We evaluated two new autoanalyzers, μTAS and Lumipulse for des-γ-carboxyprothrombin (DCP) assay. Analytical performance was evaluated, and the upper reference limit of the 97.5th percentile for DCP was re-established using sera from 140 healthy individuals. DCP levels were determined by the two autoanalyzers and EIA in a total of 239 sera from HCC patients (n=120) and those without HCC (n=119). Total imprecision of the two automated assays was <5% CV. Analytical measurement ranges (AMRs) were verified to be linear. The new reference limits were 29.5 mAU/mL for μTAS and 35.0 mAU/mL for Lumipulse. There were proportional and constant biases between the results from the autoanalyzers and those from EIA. The two newly developed DCP assays showed high analytical performance, but re-establishment of reference limits would be necessary. The new analyzers could be useful for clinical laboratories because of convenience of operation and wide AMRs. Copyright © 2011 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. The C-terminal region of Ge-1 presents conserved structural features required for P-body localization.

    PubMed

    Jinek, Martin; Eulalio, Ana; Lingel, Andreas; Helms, Sigrun; Conti, Elena; Izaurralde, Elisa

    2008-10-01

    The removal of the 5' cap structure by the DCP1-DCP2 decapping complex irreversibly commits eukaryotic mRNAs to degradation. In human cells, the interaction between DCP1 and DCP2 is bridged by the Ge-1 protein. Ge-1 contains an N-terminal WD40-repeat domain connected by a low-complexity region to a conserved C-terminal domain. It was reported that the C-terminal domain interacts with DCP2 and mediates Ge-1 oligomerization and P-body localization. To understand the molecular basis for these functions, we determined the three-dimensional crystal structure of the most conserved region of the Drosophila melanogaster Ge-1 C-terminal domain. The region adopts an all alpha-helical fold related to ARM- and HEAT-repeat proteins. Using structure-based mutants we identified an invariant surface residue affecting P-body localization. The conservation of critical surface and structural residues suggests that the C-terminal region adopts a similar fold with conserved functions in all members of the Ge-1 protein family.

  4. The simultaneous separation and determination of chloropropanols in soy sauce and other flavoring with gas chromatography-mass spectrometry in negative chemical and electron impact ionization modes.

    PubMed

    Xu, Xiaomin; Ren, Yiping; Wu, Pinggu; Han, Jianlong; Shen, Xianghong

    2006-02-01

    Both gas chromatography-mass spectrometry in electron ionization (GC-MS-EI) and negative chemical ionization (GC-MS-NCI) modes are reported in this paper for the simultaneous determination of 1,3-dichloropropan-2-ol (1,3-DCP), 2,3-dichloropropan-1-ol (2,3-DCP), 3-chloropropane-1,2-diol (3-MCPD) and 2-chloropropane-1,3-diol (2-MCPD) in soy sauce and other flavoring. D(5)-3-MCPD (for 3-MCPD and 2-MCPD) and d(5)-1,3-DCP (for 1,3-DCP and 2,3-DCP) were used as the deuterium isotopic labelled internal standards. The feasibility of using heptafluorobutyric anhydride modified with triethylamine (HFBA-Et(3)N) as a new derivatization reagent to replace heptafluorobutyrylimidazole (HFBI) is proposed. Liquid/liquid extraction with hexane was introduced for high lipid content samples. A small survey was carried out of soy sauces (103 samples) and instant noodles (45 samples) and the applicability of GC-MS-NCI and GC-MS-EI was assessed in these different matrices.

  5. Core-log integration for rock mechanics using borehole breakouts and rock strength experiments: Recent results from plate subduction margins

    NASA Astrophysics Data System (ADS)

    Saito, S.; Lin, W.

    2014-12-01

    Core-log integration has been applied for rock mechanics studies in scientific ocean drilling since 2007 in plate subduction margins such as Nankai Trough, Costa Rica margin, and Japan Trench. State of stress in subduction wedge is essential for controlling dynamics of plate boundary fault. One of the common methods to estimate stress state is analysis of borehole breakouts (drilling induced borehole wall compressive failures) recorded in borehole image logs to determine the maximum horizontal principal stress orientation. Borehole breakouts can also yield possible range of stress magnitude based on a rock compressive strength criterion. In this study, we constrained the stress magnitudes based on two different rock failure criteria, the Mohr-Coulomb (MC) criteria and the modified Wiebols-Cook (mWC) criteria. As the MC criterion is the same as that under unconfined compression state, only one rock parameter, unconfined compressive strength (UCS) is needed to constrain stress magnitudes. The mWC criterion needs the UCS, Poisson's ratio and internal frictional coefficient determined by triaxial compression experiments to take the intermediate principal stress effects on rock strength into consideration. We conducted various strength experiments on samples taken during IODP Expeditions 334/344 (Costa Rica Seismogenesis Project) to evaluate reliable method to estimate stress magnitudes. Our results show that the effects of the intermediate principal stress on the rock compressive failure occurred on a borehole wall is not negligible.

  6. Water survey of Canada: Application for use of ERTS-A for retransmission of water resources data

    NASA Technical Reports Server (NTRS)

    Halliday, R. A. (Principal Investigator); Reid, I. A.

    1974-01-01

    The author has identified the following significant results. Water resources data were retransmitted from nine data collection platforms (DCP) located in remote regions of Canada. The DCPs located in the Arctic operated in temperatures lower than -40 C and the DCP antennas have survived wind speeds of greater than 80 kph and snow loads of a depth of one metre. Ice-out indicators were installed at a few DCP sites. The purpose of these indicators was to enable the detection of the movement of ice out of river channel during spring break-up. The suitability of satellite retransmission as a means of obtaining data from remote areas of Canada continues to be demonstrated. A modest expansion of the DCP network is planned.

  7. Permeable reactive barrier of coarse sand-supported zero valent iron for the removal of 2,4-dichlorophenol in groundwater.

    PubMed

    Gao, Weichun; Zhang, Yongxiang; Zhang, Xiaoye; Duan, Zhilong; Wang, Youhao; Qin, Can; Hu, Xiao; Wang, Hao; Chang, Shan

    2015-11-01

    In this study, coarse sand-supported zero valent iron (ZVI) composite was synthesized by adding sodium alginate to immobilize. Composite was detected by scanning electron microscope (SEM), X-ray diffraction (XRD), and X-ray fluorescence (XRF). SEM results showed that composite had core-shell structure and a wide porous distribution pattern. The synthesized composite was used for degradation of 2,4-dichlorophenol (2,4-DCP) contamination in groundwater. Experimental results demonstrated that degradation mechanism of 2,4-DCP using coarse sand-supported ZVI included adsorption, desorption, and dechlorination. 2,4-DCP adsorption was described as pseudo-second-order kinetic model. It was concluded that dechlorination was the key reaction pathway, ZVI and hydrogen are prime reductants in dechlorination of 2,4-DCP using ZVI.

  8. Improved Design Formulae for Buckling of Orthotropic Plates under Combined Loading

    NASA Technical Reports Server (NTRS)

    Weaver, Paul M.; Nemeth, Michael P.

    2008-01-01

    Simple, accurate buckling interaction formulae are presented for long orthotropic plates with either simply supported or clamped longitudinal edges and under combined loading that are suitable for design studies. The loads include 1) combined uniaxial compression (or tension) and shear, 2) combined pure inplane bending and 3) shear and combined uniaxial compression (or tension) and pure inplane bending. The interaction formulae are the results of detailed regression analysis of buckling data obtained from a very accurate Rayleigh-Ritz method.

  9. Kinetic of carbonaceous substrate in an upflow anaerobic sludge sludge blanket (UASB) reactor treating 2,4 dichlorophenol (2,4 DCP).

    PubMed

    Sponza, Delia Teresa; Uluköy, Ayşen

    2008-01-01

    The performance of an upflow anaerobic sludge blanket (UASB) reactor treating 2,4 dichlorophenol (2,4 DCP) was evaluated at different hydraulic retention times (HRTs) using synthetic wastewater in order to obtain the growth substrate (glucose-COD) and 2,4 DCP removal kinetics. Treatment efficiencies of the UASB reactor were investigated at different hydraulic retention times (2-20 h) corresponding to a food to mass (F/M) ratio of 1.2-1.92 g-COD g(-1) VSS day(-1). A total of 65-83% COD removal efficiencies were obtained at HRTs of 2-20 h. In all, 83% and 99% 2,4 DCP removals were achieved at the same HRTs in the UASB reactor. Conventional Monod, Grau Second-order and Modified Stover-Kincannon models were applied to determine the substrate removal kinetics of the UASB reactor. The experimental data obtained from the kinetic models showed that the Monod kinetic model is more appropriate for correlating the substrate removals compared to the other models for the UASB reactor. The maximum specific substrate utilization rate (k) (mg-COD mg(-1) SS day(-1)), half-velocity concentration (K(s)) (mg COD l(-1)), growth yield coefficient (Y) (mg mg(-1)) and bacterial decay coefficient (b) (day(-1)) were 0.954 mg-COD mg(-1) SS day(-1), 560.29 mg-COD l(-1), 0.78 mg-SS g(-1)-COD, 0.093 day(-1) in the Conventional Monod kinetic model. The second-order kinetic coefficient (k(2)) was calculated as 0.26 day(-1) in the Grau reaction kinetic model. The maximum COD removal rate constant (U(max)) and saturation value (K(B)) were calculated as 7.502 mg CODl(-1)day(-1) and 34.56 mg l(-1)day(-1) in the Modified Stover-Kincannon Model. The (k)(mg-2,4 DCP mg(-1) SS day(-1)), (K(s)) (mg 2,4 DCPl(-1)), (Y) (mg SS mg(-1) 2,4 DCP) and (k(d)) (day(-1)) were 0.0041 mg-2,4 DCP mg(-1) SS day(-1), 2.06 mg-COD l(-1), 0.0017 mg-SS mg(-1) 2,4 DCP and 3.1 x 10(-5) day(-1) in the Conventional Monod kinetic model for 2,4 DCP degradation. The second-order kinetic coefficient (k(2)) was calculated as 0.30 day(-1) in the Grau reaction kinetic model. The maximum 2,4 DCP removal rate constant (U(max)) and saturation value (K(B)) were calculated as 0.01 mg COD l(-1) day(-1) and 9.8 x 10(-3) mg l(-1) day(-1) in the Modified Stover-Kincannon model.

  10. Flexible DCP interface. [signal conditioning system for use with Kansas environmental sensors

    NASA Technical Reports Server (NTRS)

    Kanemasu, E. T. (Principal Investigator); Schimmelpfenning, H.

    1974-01-01

    The author has identified the following significant results. A user of an ERTS data collection system must supply the sensors and signal conditioning interface. The electronic interface must be compatible with the NASA-furnished data collection platform (DCP). A universal signal conditioning system for use with a wide range of environmental sensors is described. The interface is environmentally and electronically compatible with the DCP and has operated satisfactorily for a complete winter wheat growing season in Kansas.

  11. Measurement of effective bulk and contact resistance of gas diffusion layer under inhomogeneous compression - Part I: Electrical conductivity

    NASA Astrophysics Data System (ADS)

    Vikram, Ajit; Chowdhury, Prabudhya Roy; Phillips, Ryan K.; Hoorfar, Mina

    2016-07-01

    This paper describes a measurement technique developed for the determination of the effective electrical bulk resistance of the gas diffusion layer (GDL) and the contact resistance distribution at the interface of the GDL and the bipolar plate (BPP). The novelty of this study is the measurement and separation of the bulk and contact resistance under inhomogeneous compression, occurring in an actual fuel cell assembly due to the presence of the channels and ribs on the bipolar plates. The measurement of the electrical contact resistance, contributing to nearly two-third of the ohmic losses in the fuel cell assembly, shows a non-linear distribution along the GDL/BPP interface. The effective bulk resistance of the GDL under inhomogeneous compression showed a decrease of nearly 40% compared to that estimated for homogeneous compression at different compression pressures. Such a decrease in the effective bulk resistance under inhomogeneous compression could be due to the non-uniform distribution of pressure under the ribs and the channels. This measurement technique can be used to identify optimum GDL, BPP and channel-rib structures based on minimum bulk and contact resistances measured under inhomogeneous compression.

  12. Diagnostic utility of alpha-fetoprotein and des-gamma-carboxyprothrombin in nigerians with hepatocellular carcinoma.

    PubMed

    Ette, Akpakip Ikpong; Ndububa, D A; Adekanle, O; Ekrikpo, U

    2017-10-01

    Alpha-fetoprotein (AFP) and Des-gamma-carboxyprothrombin (DCP) have been extensively studied as biomarkers for the diagnosis of and prognostication in hepatocellular carcinoma (HCC). However there are only few reports on the clinical characteristics of hepatocellular carcinoma in relation to the combination of the two tumor markers in hepatitis B virus-related HCC. The aim of this study was to investigate the clinical characteristics of HBV-related HCC in relation to different sets of AFP and DCP values. Sixty-two patients with untreated HCC were studied. The positive value of AFP was set at 20 1U/L while DCP positive value was set at 150 mAU/ml. Patients were divided into three groups: Group 1(n=36) with AFP ≥ 20 IU/L and DCP ≥ 150 mAU/ml. Group 2(n=24) with AFP <20 1U/L and DCP ≥ 150 mAU/ml. Group 3 (n=2) with AFP < 20 1U/L and DCP < 150 mAU/ml. There were no patients in group 4 meant for those with AFP ≥ 20 1U/L and DCP < 150 mAU/ml. Clinical and laboratory variables were compared among the groups. Clinical and laboratory variables were comparable among the groups with the exception of gender and values of serum alanine aminotransferase (ALT). Males were significantly more than females among the groups (p<0.03). ALT values were significantly different among the groups (p<0.006). Paired comparisons between the groups showed the mean values of serum ALT were significantly higher in group 2 than in group 1(p<0.003). The mean serum ALT values were also higher in group 2 than in group 3 (p <0.014). There was no significant difference between group 1 and group 3 (P = 0.124). HCC patients who are sero-positive for DCP and sero-negative for AFP have significantly higher levels of serum ALT; serum ALT levels may be of diagnostic importance in AFP-negative, HBV-related HCC patients.

  13. Physics of singularities in pressure-impulse theory

    NASA Astrophysics Data System (ADS)

    Krechetnikov, R.

    2018-05-01

    The classical solution in the pressure-impulse theory for the inviscid, incompressible, and zero-surface-tension water impact of a flat plate at zero dead-rise angle exhibits both singular-in-time initial fluid acceleration, ∂v /∂ t |t =0˜δ (t ) , and a near-plate-edge spatial singularity in the velocity distribution, v ˜r-1 /2 , where r is the distance from the plate edge. The latter velocity divergence also leads to the interface being stretched infinitely right after the impact, which is another nonphysical artifact. From the point of view of matched asymptotic analysis, this classical solution is a singular limit when three physical quantities achieve limiting values: sound speed c0→∞ , fluid kinematic viscosity ν →0 , and surface tension σ →0 . This leaves open a question on how to resolve these singularities mathematically by including the neglected physical effects—compressibility, viscosity, and surface tension—first one by one and then culminating in the local compressible viscous solution valid for t →0 and r →0 , demonstrating a nontrivial flow structure that changes with the degree of the bulk compressibility. In the course of this study, by starting with the general physically relevant formulation of compressible viscous flow, we clarify the parameter range(s) of validity of the key analytical solutions including classical ones (inviscid incompressible and compressible, etc.) and understand the solution structure, its intermediate asymptotics nature, characteristics influencing physical processes, and the role of potential and rotational flow components. In particular, it is pointed out that sufficiently close to the plate edge surface tension must be taken into account. Overall, the idea is to highlight the interesting physics behind the singularities in the pressure-impulse theory.

  14. An approach to improve the spatial resolution of a force mapping sensing system

    NASA Astrophysics Data System (ADS)

    Negri, Lucas Hermann; Manfron Schiefer, Elberth; Sade Paterno, Aleksander; Muller, Marcia; Luís Fabris, José

    2016-02-01

    This paper proposes a smart sensor system capable of detecting sparse forces applied to different positions of a metal plate. The sensing is performed with strain transducers based on fiber Bragg gratings (FBG) distributed under the plate. Forces actuating in nine squared regions of the plate, resulting from up to three different loads applied simultaneously to the plate, were monitored with seven transducers. The system determines the magnitude of the force/pressure applied on each specific area, even in the absence of a dedicated transducer for that area. The set of strain transducers with coupled responses and a compressive sensing algorithm are employed to solve the underdetermined inverse problem which emerges from mapping the force. In this configuration, experimental results have shown that the system is capable of recovering the value of the load distributed on the plate with a signal-to-noise ratio better than 12 dB, when the plate is submitted to three simultaneous test loads. The proposed method is a practical illustration of compressive sensing algorithms for the reduction of the number of FBG-based transducers used in a quasi-distributed configuration.

  15. Three-dimensional analytical solution for the instability of a parallel array of mutually attracting identical simply supported piezoelectric microplates

    NASA Astrophysics Data System (ADS)

    Liu, Lei; Wang, Xu

    2017-12-01

    Three-dimensional analytical solutions are derived for the structural instability of a parallel array of mutually attracting identical simply supported orthotropic piezoelectric rectangular microplates by means of a linear perturbation analysis. The two surfaces of each plate can be either insulating or conducting. By considering the fact that the shear stresses and the normal electric displacement (or electric potential) are zero on the two surfaces of each plate, a 2 × 2 transfer matrix for a plate can be obtained directly from the 8 × 8 fundamental piezoelectricity matrix without resolving the original Stroh eigenrelation. The critical interaction coefficient can be determined by solving the resulting generalized eigenvalue problem for the piezoelectric plate array. Also considered in our analysis is the in-plane uniform edge compression acting on the four sides of each piezoelectric plate. Our results indicate that the stabilizing influence of the piezoelectric effect on the structural instability is unignorable; the edge compression always plays a destabilizing role in the structural instability of the plate array with interactions.

  16. Multiscale modeling of growth plate cartilage mechanobiology.

    PubMed

    Gao, Jie; Williams, John L; Roan, Esra

    2017-04-01

    Growth plate chondrocytes are responsible for bone growth through proliferation and differentiation. However, the way they experience physiological loads and regulate bone formation, especially during the later developmental phase in the mature growth plate, is still under active investigation. In this study, a previously developed multiscale finite element model of the growth plate is utilized to study the stress and strain distributions within the cartilage at the cellular level when rapidly compressed to 20 %. Detailed structures of the chondron are included in the model to examine the hypothesis that the same combination of mechanoregulatory signals shown to maintain cartilage or stimulate osteogenesis or fibrogenesis in the cartilage anlage or fracture callus also performs the same function at the cell level within the chondrons of growth plate cartilage. Our cell-level results are qualitatively and quantitatively in agreement with tissue-level theories when both hydrostatic cellular stress and strain are considered simultaneously in a mechanoregulatory phase diagram similar to that proposed at the tissue level by Claes and Heigele for fracture healing. Chondrocytes near the reserve/proliferative zone border are subjected to combinations of high compressive hydrostatic stresses ([Formula: see text] MPa), and cell height and width strains of [Formula: see text] to [Formula: see text] respectively, that maintain cartilage and keep chondrocytes from differentiating and provide conditions favorable for cell division, whereas chondrocytes closer to the hypertrophic/calcified zone undergo combinations of lower compressive hydrostatic stress ([Formula: see text] MPa) and cell height and width strains as low as [Formula: see text] to +4 %, respectively, that promote cell differentiation toward osteogenesis; cells near the outer periphery of the growth plate structure experience a combination of low compressive hydrostatic stress (0 to [Formula: see text] MPa) and high maximum principal strain (20-29 %) that stimulate cell differentiation toward fibrocartilage or fibrous tissue.

  17. Importance of Considering the Middle Capillary Plexus on OCT Angiography in Diabetic Retinopathy.

    PubMed

    Onishi, Alex C; Nesper, Peter L; Roberts, Philipp K; Moharram, Ganna A; Chai, Haitao; Liu, Lei; Jampol, Lee M; Fawzi, Amani A

    2018-04-01

    To quantify microvasculature changes in the superficial (SCP), middle (MCP), and deep capillary plexuses (DCP) in diabetic retinopathy (DR). Retrospective cross-sectional study at a tertiary academic referral center, in which 26 controls (44 eyes), 27 diabetic subjects without retinopathy (44 eyes), 32 subjects with nonproliferative retinopathy (52 eyes), and 27 subjects with proliferative retinopathy (40 eyes) were imaged with optical coherence tomography angiography (OCTA). Outcome measures included parafoveal vessel density (VD), percentage area of nonperfusion (PAN), and adjusted flow index (AFI) at the different plexuses. MCP VD and MCP AFI decreased with worsening DR, while PAN increased, mirroring changes within the DCP. The fitted regression line for MCP and DCP AFI were significantly different than the SCP, while DCP PAN differed from SCP PAN with disease progression. Higher SCP AFI and PAN were different in eyes with diabetes without retinopathy compared with controls. Unexpectedly, sex was found to independently influence MCP VD and AFI with worsening disease. OCTA parameters in the MCP and DCP displayed parallel changes with DR progression, different from the SCP, emphasizing the importance of physiologic considerations in the retinal capillaries. Thus, segmentation protocols that include the MCP within the SCP may be confounded. A difference in DCP PAN with worsening DR was unmasked relative to a prior study that included the MCP with SCP. We confirm that SCP AFI and PAN may serve as early indicators of microvascular changes in DR and identify an interaction between sex and the MCP deserving further study.

  18. Theoretical comparative studies on transport properties of pentacene, pentathienoacene, and 6,13-dichloropentacene.

    PubMed

    Zhang, Xu; Yang, Xiaodi; Geng, Hua; Nan, Guangjun; Sun, Xingwen; Xi, Jinyang; Xu, Xin

    2015-05-05

    Pentacene derivative 6,13-dichloropentacene (DCP) is one of the latest additions to the family of organic semiconductors with a great potential for use in transistors. We carry out a detailed theoretical calculation for DCP, with systematical comparison to pentacene, pentathienoacene (PTA, the thiophene equivalent of pentacene), to gain insights in the theoretical design of organic transport materials. The charge transport parameters and carrier mobilities are investigated from the first-principles calculations, based on the widely used Marcus electron transfer theory and quantum nuclear tunneling model, coupled with random walk simulation. Molecular structure and the crystal packing type are essential to understand the differences in their transport behaviors. With the effect of molecule modification, significant one-dimensional π-stacks are found within the molecular layer in PTA and DCP crystals. The charge transport along the a-axis plays a dominant role for the carrier mobilities in the DCP crystal due to the strong transfer integrals within the a-axis. Pentacene shows a relatively large 3D mobility. This is attributed to the relatively uniform electronic couplings, which thus provides more transport pathways. PTA has a much smaller 3D mobility than pentacene and DCP for the obvious increase of the reorganization energy with the introduction of thiophene. It is found that PTA and DCP exhibit lower HOMO (highest occupied molecular orbital) levels and better environmental stability, indicating the potential applications in organic electronics. © 2015 Wiley Periodicals, Inc.

  19. Responses of soluble microbial products and extracellular polymeric substances to the presence of toxic 2,6-dichlorophenol in aerobic granular sludge system.

    PubMed

    Li, Kai; Wei, Dong; Yan, Tao; Du, Bin; Wei, Qin

    2016-12-01

    The objective of this study was to evaluate the responses of soluble microbial products (SMP) and extracellular polymeric substances (EPS) to the presence of toxic 2,6-dichlorophenol (2,6-DCP) in aerobic granular sludge (AGS) system. Batch experiment showed that NH 4 + -N removal efficiency significantly decreased from 99.6% to 47.2% in the toxic 2,6-DCP of 20 mg/L. Moreover, the inhibition degrees of 2,6-DCP on (SOUR) H , [Formula: see text] and [Formula: see text] were 7.8%, 32.1% and 9.5%, respectively. The main components of SMP, including protein (PN) and polysaccharide (PS) increased from 2.3 ± 0.74 and 16.8 ± 0.12 mg/L to 66.4 ± 0.56 and 18.0 ± 0.19 mg/L in the presence of 2,6-DCP. Three-dimensional excitation-emission matrix (3D-EEM) spectroscopy identified tryptophan PN-like, humic acid-like and fulvic acid-like substances in the control SMP, and their fluorescence intensities increased after exposure to 2,6-DCP. Synchronous fluorescence spectra suggested that the fluorescence quenching between EPS and 2,6-DCP was a static quenching process. The obtained results could provide insightful information on the responses of microbial products to AGS in the presence of toxic chlorophenols. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Transform push, oblique subduction resistance, and intraplate stress of the Juan de Fuca plate

    USGS Publications Warehouse

    Wang, K.; He, J.; Davis, E.E.

    1997-01-01

    The Juan de Fuca plate is a small oceanic plate between the Pacific and North America plates. In the southernmost region, referred to as the Gorda deformation zone, the maximum compressive stress a, constrained by earthquake focal mechanisms is N-S. Off Oregon, and possibly off Washington, NW trending left-lateral faults cutting the Juan de Fuca plate indicate a a, in a NE-SW to E-W direction. The magnitude of differential stress increases from north to south; this is inferred from the plastic yielding and distribution of earthquakes throughout the Gorda deformation zone. To understand how tectonic forces determine the stress field of the Juan de Fuca plate, we have modeled the intraplate stress using both elastic and elastic-perfectly plastic plane-stress finite element models. We conclude that the right-lateral shear motion of the Pacific and North America plates is primarily responsible for the stress pattern of the Juan de Fuca plate. The most important roles are played by a compressional force normal to the Mendocino transform fault, a result of the northward push by the Pacific plate and a horizontal resistance operating against the northward, or margin-parallel, component of oblique subduction. Margin-parallel subduction resistance results in large N-S compression in the Gorda deformation zone because the force is integrated over the full length of the Cascadia subduction zone. The Mendocino transform fault serves as a strong buttress that is very weak in shear but capable of transmitting large strike-normal compressive stresses. Internal failure of the Gorda deformation zone potentially places limits on the magnitude of the fault-normal stresses being transmitted and correspondingly on the magnitude of strike-parallel subduction resistance. Transform faults and oblique subduction zones in other parts of the world can be expected to transmit and create stresses in the same manner. Copyright 1997 by the American Geophysical Union.

  1. The Use of Sphere Indentation Experiments to Characterize Ceramic Damage Models

    DTIC Science & Technology

    2011-09-01

    state having two equal eigenvalues. For TXC, the axial stress (single eigenvalue) is more compressive than the lateral stresses (dual eigenvalues). For...parameters. These dynamic experiments supplement traditional characterization experiments such as tension, triaxial compression , Brazilian, and...These dynamic experiments supplement traditional characterization experiments such as tension, triaxial compression , Brazilian, and plate impact, which

  2. Triple shape memory effects of cross-linked polyethylene/polypropylene blends with cocontinuous architecture.

    PubMed

    Zhao, Jun; Chen, Min; Wang, Xiaoyan; Zhao, Xiaodong; Wang, Zhenwen; Dang, Zhi-Min; Ma, Lan; Hu, Guo-Hua; Chen, Fenghua

    2013-06-26

    In this paper, the triple shape memory effects (SMEs) observed in chemically cross-linked polyethylene (PE)/polypropylene (PP) blends with cocontinuous architecture are systematically investigated. The cocontinuous window of typical immiscible PE/PP blends is the volume fraction of PE (v(PE)) of ca. 30-70 vol %. This architecture can be stabilized by chemical cross-linking. Different initiators, 2,5-dimethyl-2,5-di(tert-butylperoxy)-hexane (DHBP), dicumylperoxide (DCP) coupled with divinylbenzene (DVB) (DCP-DVB), and their mixture (DHBP/DCP-DVB), are used for the cross-linking. According to the differential scanning calorimetry (DSC) measurements and gel fraction calculations, DHBP produces the best cross-linking and DCP-DVB the worst, and the mixture, DHBP/DCP-DVB, is in between. The chemical cross-linking causes lower melting temperature (Tm) and smaller melting enthalpy (ΔHm). The prepared triple shape memory polymers (SMPs) by cocontinuous immiscible PE/PP blends with v(PE) of 50 vol % show pronounced triple SMEs in the dynamic mechanical thermal analysis (DMTA) and visual observation. This new strategy of chemically cross-linked immiscible blends with cocontinuous architecture can be used to design and prepare new SMPs with triple SMEs.

  3. Long term measurement network for FIFE

    NASA Technical Reports Server (NTRS)

    Blad, Blaine L.; Walter-Shea, Elizabeth A.; Hays, Cynthia J.

    1988-01-01

    The objectives were: to obtain selected instruments which were not standard equipment on the Portable Automated Mesometeorological (PAM) and Data Control Platform (DCP) stations; to assist in incorporation of these instruments onto the PAM and DCP stations; to help provide routine maintenance of the instruments; to conduct periodic instrument calibrations; and to repair or replace malfunctioning instruments when possible. All of the objectives were or will be met soon. All instruments and the necessary instrument stands were purchased or made and were available for inclusion on the PAM and DCP stations before the beginning of the IFC-1. Due to problems beyond control, the DCP stations experienced considerable difficulty in becoming operational. To fill some of the gaps caused by the DCP problems, Campbell CR21-X data loggers were installed and the data collected on cassette tapes. Periodic checks of all instruments were made, to maintain data quality, to make necessary adjustments in certain instruments, to replace malfunctioning instruments, and to provide instrument calibration. All instruments will be calibrated before the beginning of the 1988 growing season as soon as the weather permits access to all stations and provides conditions that are not too harsh to work in for extended periods of time.

  4. Degradation of 2,4-dichlorophenol with a novel TiO2/Ti-Fe-graphite felt photoelectrocatalytic oxidation process.

    PubMed

    Zhao, Bao-xiu; Li, Xiang-zhong; Wang, Peng

    2007-01-01

    Degradation of 2,4-dichlorophenol (2,4-DCP) was studied in a novel three-electrode photoelectrocatalytic (PEC) integrative oxidation process, and the factors influencing the degradation rate, such as applied current, flow speed of O2, pH, adscititious voltage and initial 2,4-DCP concentration were investigated and optimized. H2O2 was produced nearby cathode and Fe2+ continuously generated from Fe anode in solution when current and O2 were applied, so, main reactions, H2O2-assisted TiO2 PEC oxidation and E-Fenton reaction, occurred during degradation of 2,4-DCP in this integrative system. The degradation ratio of 2,4-DCP was 93% in this integrative oxidation process, while it was only 31% in E-Fenton process and 46% in H2O2-assisted TiO2 PEC process. So, it revealed that the degradation of 2,4-DCP was improved greatly by photoelectrical cooperation effect. By the investigation of pH, it showed that this integrative process could work well in a wide pH range from pH 3 to pH 9.

  5. Evaluation of the Dignity Care Pathway for community nurses caring for people at the end of life.

    PubMed

    Johnston, Bridget; Östlund, Ulrika; Brown, Hilary

    2012-10-01

    People nearing the end of life fear loss of dignity, and a central tenet of palliative care is to help people die with dignity. The Dignity Care Pathway (DCP) is an intervention based on the Chochinov theoretical model of dignity care. It has four sections: a manual, a Patient Dignity Inventory, reflective questions, and care actions. The feasibility and acceptability of the DCP were evaluated using a qualitative design with a purposive sample of community nurses. Data was collected from April to October 2010 using in-depth interviews, reflective diaries, and case studies and then analysed using framework analysis. The DCP was acceptable to the community nurses, helped them identify when patients were at the end of life, identified patients' key concerns, and aided nurses in providing holistic end-of-life care. It requires the nurse to have excellent communication skills. Some of the nurses found it hard to initiate a conversation on dignity-conserving care. The DCP helps nurses to deliver individualised care and psychological care, which has previously been identified as a difficult area for community nurses. All of the nurses wished to continue to use the DCP and would recommend it to others.

  6. Rotary shaft seal

    DOEpatents

    Langebrake, C.O.

    1984-01-01

    The invention is a novel rotary shaft seal assembly which provides positive-contact sealing when the shaft is not rotated and which operates with its sealing surfaces separated by a film of compressed ambient gas whose width is independent of the speed of shaft rotation. In a preferred embodiment, the assembly includes a disc affixed to the shaft for rotation therewith. Axially movable, non-rotatable plates respectively supported by sealing bellows are positioned on either side of the disc to be in sealing engagement therewith. Each plate carries piezoelectric transucer elements which are electrically energized at startup to produce films of compressed ambient gas between the confronting surfaces of the plates and the disc. Following shutdown of the shaft, the transducer elements are de-energized. A control circuit responds to incipient rubbing between the plate and either disc by altering the electrical input to the transducer elements to eliminate rubbing.

  7. Rotary shaft seal

    DOEpatents

    Langebrake, Clair O.

    1984-01-01

    The invention is a novel rotary shaft seal assembly which provides positive-contact sealing when the shaft is not rotated and which operates with its sealing surfaces separated by a film of compressed ambient gas whose width is independent of the speed of shaft rotation. In a preferred embodiment, the assembly includes a disc affixed to the shaft for rotation therewith. Axially movable, non-rotatable plates respectively supported by sealing bellows are positioned on either side of the disc to be in sealing engagement therewith. Each plate carries piezoelectric transducer elements which are electrically energized at startup to produce films of compressed ambient gas between the confronting surfaces of the plates and the disc. Following shutdown of the shaft, the transducer elements are de-energized. A control circuit responds to incipient rubbing between the plate and either disc by altering the electrical input to the transducer elements to eliminate rubbing.

  8. Shock compression experiments on Lithium Deuteride (LiD) single crystals

    DOE PAGES

    Knudson, M. D.; Desjarlais, M. P.; Lemke, R. W.

    2016-12-21

    Shock compression experiments in the few hundred GPa (multi-Mabr) regime were performed on Lithium Deuteride (LiD) single crystals. This study utilized the high velocity flyer plate capability of the Sandia Z Machine to perform impact experiments at flyer plate velocities in the range of 17-32 km/s. Measurements included pressure, density, and temperature between ~200-600 GPa along the Principal Hugoniot – the locus of end states achievable through compression by large amplitude shock waves – as well as pressure and density of re - shock states up to ~900 GPa. Lastly, the experimental measurements are compared with recent density functional theorymore » calculations as well as a new tabular equation of state developed at Los Alamos National Labs.« less

  9. Fuel cell current collector

    DOEpatents

    Katz, Murray; Bonk, Stanley P.; Maricle, Donald L.; Abrams, Martin

    1991-01-01

    A fuel cell has a current collector plate (22) located between an electrode (20) and a separate plate (25). The collector plate has a plurality of arches (26, 28) deformed from a single flat plate in a checkerboard pattern. The arches are of sufficient height (30) to provide sufficient reactant flow area. Each arch is formed with sufficient stiffness to accept compressive load and sufficient resiliently to distribute the load and maintain electrical contact.

  10. Near Continuum Velocity and Temperature Coupled Compressible Boundary Layer Flow over a Flat Plate

    NASA Astrophysics Data System (ADS)

    He, Xin; Cai, Chunpei

    2017-04-01

    The problem of a compressible gas flows over a flat plate with the velocity-slip and temperature-jump boundary conditions are being studied. The standard single- shooting method is applied to obtain the exact solutions for velocity and temperature profiles when the momentum and energy equations are weakly coupled. A double-shooting method is applied if these two equations are closely coupled. If the temperature affects the velocity directly, more significant velocity slip happens at locations closer to the plate's leading edge, and inflections on the velocity profiles appear, indicating flows may become unstable. As a consequence, the temperature-jump and velocity-slip boundary conditions may trigger earlier flow transitions from a laminar to a turbulent flow state.

  11. Validation of High-Speed Turbulent Boundary Layer and Shock-Boundary Layer Interaction Computations with the OVERFLOW Code

    NASA Technical Reports Server (NTRS)

    Oliver, A. B.; Lillard, R. P.; Blaisdell, G. A.; Lyrintizis, A. S.

    2006-01-01

    The capability of the OVERFLOW code to accurately compute high-speed turbulent boundary layers and turbulent shock-boundary layer interactions is being evaluated. Configurations being investigated include a Mach 2.87 flat plate to compare experimental velocity profiles and boundary layer growth, a Mach 6 flat plate to compare experimental surface heat transfer,a direct numerical simulation (DNS) at Mach 2.25 for turbulent quantities, and several Mach 3 compression ramps to compare computations of shock-boundary layer interactions to experimental laser doppler velocimetry (LDV) data and hot-wire data. The present paper describes outlines the study and presents preliminary results for two of the flat plate cases and two small-angle compression corner test cases.

  12. Assessment of function-graded materials as fracture fixation bone-plates under combined loading conditions using finite element modelling.

    PubMed

    Fouad, H

    2011-05-01

    In previous work by Fouad (Medical Engineering and Physics 2010 [23]), 3D finite element (FE) models for fractured bones with function-graded (FG) bone-plates and traditional bone-plates made of stainless steel (SS) and titanium (Ti) alloy were examined under compressive loading conditions using the ABAQUS Code. In this study, the effects of the presence of the torsional load in addition to the compressive load on the predicted stresses of the fracture fixation bone-plate system are examined at different healing stages. The effects on the stress on the fracture site when using contacted and non-contacted bone-plate systems are also studied. The FE modelling results indicate that the torsional load has significant effects on the resultant stress on the fracture fixation bone-plate system, which should be taken into consideration during the design and the analysis. The results also show that the stress shielding at the fracture site decreases significantly when using FG bone-plates compared to Ti alloy or SS bone-plates. The presence of a gap between the bone and the plate results in a remarkable reduction in bone stress shielding at the fracture site. Therefore, the significant effects of using an FG bone-plate with a gap and the presence of torsional load on the resultant stress on the fracture fixation bone-plate system should be taken into consideration. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Diagnostic Evaluation of Des-Gamma-Carboxy Prothrombin versus α-Fetoprotein for Hepatitis B Virus-Related Hepatocellular Carcinoma in China: A Large-Scale, Multicentre Study

    PubMed Central

    Zheng, Lei; Yin, Yuepeng; Zou, Zhenzhen; Zhou, Feiguo; Zhou, Weiping; Shen, Feng; Gao, Chunfang

    2016-01-01

    An efficient serum marker for hepatocellular carcinoma (HCC) is currently lacking and requires intensive exploration. We aimed to evaluate the performance of des-gamma-carboxy prothrombin (DCP) for identifying hepatitis B virus-related HCC in a large, multicentre study in China. A total of 1034 subjects in three cohorts (A, B, and C) including HCC and various non-HCC controls were enrolled from 4 academic medical centers in China from January 2011 to February 2014. Blind parallel detections were conducted for DCP and AFP. The area under the receiver operating characteristic curve (AUC) was used to evaluate the diagnostic efficacies. In cohort A, which comprised 521 subjects, including patients with HCC, liver metastasis, liver cirrhosis (LC), and liver hemangiomas as well as healthy controls (HCs), the accuracy of DCP for distinguishing HCC from various controls was 6.2–9.7% higher than that of AFP. In cohort B, which comprised 447 subjects, including patients with HCC, LC, and chronic hepatitis B as well as HC, the accuracy of DCP was further elevated (12.3–20.67% higher than that of AFP). The superiority of DCP to AFP was more profound in the surveillance of early HCC [AUC 0.837 (95% CI: 0.771–0.903) vs. 0.650 (0.555–0.745)] and AFP-negative HCC [AUC: 0.856 (0.798–0.914)] and in discriminating HCC from LC (accuracy: 92.9% vs.64.71%). Higher DCP levels were associated with worse clinical behaviors and shorter disease-free survival. DCP not only is complementary to AFP in identifying AFP-negative HCC and in excluding AFP-positive non-HCC (liver cirrhosis), but also demonstrates improved performance in HCC surveillance, early diagnosis, treatment response and recurrence monitoring in the HBV-related population. PMID:27070780

  14. Conceptual finite element study for comparison among superior, anterior, and spiral clavicle plate fixations for midshaft clavicle fracture.

    PubMed

    Huang, Teng-Le; Chen, Wen-Chuan; Lin, Kun-Jhih; Tsai, Cheng-Lun; Lin, Kang-Ping; Wei, Hung-Wen

    2016-10-01

    Open reduction internal fixation technique has been generally accepted for treatment of midshaft clavicle fractures. Both superior and anterior clavicle plates have been reported in clinical or biomechanical researches, while presently the spiral clavicle plate design has been introduced improved biomechanical behavior over conventional designs. In order to objectively realize the multi-directional biomechanical performances among the three geometries for clavicle plate designs, a current conceptual finite element study has been conducted with identical cross-sectional features for clavicle plates. The conceptual superior, anterior, and spiral clavicle plate models were constructed for virtual reduction and fixation to an OTA 15-B1.3 midshaft transverse fracture of clavicle. Mechanical load cases including cantilever bending, axial compression, inferior bending, and axial torsion have been applied for confirming the multi-directional structural stability and implant safety in biomechanical perspective. Results revealed that the anterior clavicle plate model represented lowest plate stress under all loading cases. The superior clavicle plate model showed greater axial compressive stiffness, while the anterior clavicle plate model performed greater rigidity under cantilever bending load. Three model represented similar structural stiffness under axial torsion. Played as a transition structure between superior and anterior clavicle plate, the spiral clavicle plate model revealed comparable results with acceptable multi-directional biomechanical behavior. The concept of spiral clavicle plate design is worth considering in practical application in clinics. Implant safety should be further investigated by evidences in future mechanical tests and clinical observations. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Compressible Navier-Stokes equations: A study of leading edge effects

    NASA Technical Reports Server (NTRS)

    Hariharan, S. I.; Karbhari, P. R.

    1987-01-01

    A computational method is developed that allows numerical calculations of the time dependent compressible Navier-Stokes equations.The current results concern a study of flow past a semi-infinite flat plate.Flow develops from given inflow conditions upstream and passes over the flat plate to leave the computational domain without reflecting at the downstream boundary. Leading edge effects are included in this paper. In addition, specification of a heated region which gets convected with the flow is considered. The time history of this convection is obtained, and it exhibits a wave phenomena.

  16. A study of universal modulation techniques applied to satellite data collection

    NASA Technical Reports Server (NTRS)

    1980-01-01

    A universal modulation and frequency control system for use with data collection platform (DCP) transmitters is examined. The final design discussed can, under software/firmwave control, generate all of the specific digital data modulation formats currently used in the NASA satellite data collection service and can simultaneously synthesize the proper RF carrier frequencies employed. A novel technique for DCP time and frequency control is presented. The emissions of NBS radio station WWV/WWVH are received, detected, and finally decoded in microcomputer software to generate a highly accurate time base for the platform; with the assistance of external hardware, the microcomputer also directs the recalibration of all DCP oscillators to achieve very high frequency accuracies and low drift rates versus temperature, supply voltage, and time. The final programmable DCP design also employs direct microcomputer control of data reduction, formatting, transmitter switching, and system power management.

  17. Assessing the local mechanical environment in medial opening wedge high tibial osteotomy using finite element analysis.

    PubMed

    Pauchard, Yves; Ivanov, Todor G; McErlain, David D; Milner, Jaques S; Giffin, J Robert; Birmingham, Trevor B; Holdsworth, David W

    2015-03-01

    High-tibial osteotomy (HTO) is a surgical technique aimed at shifting load away from one tibiofemoral compartment, in order the reduce pain and progression of osteoarthritis (OA). Various implants have been designed to stabilize the osteotomy and previous studies have been focused on determining primary stability (a global measure) that these designs provide. It has been shown that the local mechanical environment, characterized by bone strains and segment micromotion, is important in understanding healing and these data are not currently available. Finite element (FE) modeling was utilized to assess the local mechanical environment provided by three different fixation plate designs: short plate with spacer, long plate with spacer and long plate without spacer. Image-based FE models of the knee were constructed from healthy individuals (N = 5) with normal knee alignment. An HTO gap was virtually added without changing the knee alignment and HTO implants were inserted. Subsequently, the local mechanical environment, defined by bone compressive strain and wedge micromotion, was assessed. Furthermore, implant stresses were calculated. Values were computed under vertical compression in zero-degree knee extension with loads set at 1 and 2 times the subject-specific body weight (1 BW, 2 BW). All studied HTO implant designs provide an environment for successful healing at 1 BW and 2 BW loading. Implant von Mises stresses (99th percentile) were below 60 MPa in all experiments, below the material yield strength and significantly lower in long spacer plates. Volume fraction of high compressive strain ( > 3000 microstrain) was below 5% in all experiments and no significant difference between implants was detected. Maximum vertical micromotion between bone segments was below 200 μm in all experiments and significantly larger in the implant without a tooth. Differences between plate designs generally became apparent only at 2 BW loading. Results suggest that with compressive loading of 2 BW, long spacer plates experience the lowest implant stresses, and spacer plates (long or short) result in smaller wedge micromotion, potentially beneficial for healing. Values are sensitive to subject bone geometry, highlighting the need for subject-specific modeling. This study demonstrates the benefits of using image-based FE modeling and bone theory to fine-tune HTO implant design.

  18. The relationship of photoreceptor degeneration to retinal vascular development and loss in mutant rhodopsin transgenic and RCS rats.

    PubMed

    Pennesi, Mark E; Nishikawa, Shimpei; Matthes, Michael T; Yasumura, Douglas; LaVail, Matthew M

    2008-12-01

    The early loss of photoreceptors in some retinal degenerations in mice has been shown to have a profound effect on vascular development of the retina. To better characterize this relationship, we have examined the formation of retinal blood vessels during the first month of life in 8 lines of transgenic rats with different ages of onset and rates of photoreceptor cell loss mediated by the expression of mutant rhodopsin (P23H and S334ter). The number of capillary profiles in the superficial plexus (SP) and deep capillary plexus (DCP) of the retina were quantified in retinal sections taken at postnatal day (P) 8, 10, 12, 15 and 30. In normal wild-type rats, the SP and DCP had mostly established mature, adult patterns by P15, as previously shown. In the transgenic rats, the loss of photoreceptors had relatively little effect on the SP. By contrast, the loss of photoreceptors during vascular development had a major impact on the DCP. In the two lines with early and most rapid photoreceptor loss, S334ter-7 and S334ter-3, where about 90% and 65%, respectively, of the photoreceptors were already lost by P15, the DCP either failed to form (S334ter-7) or the number of capillary profiles was less than 7% of controls (S334ter-3). In lines where almost all photoreceptors were still present at P15 (S334ter-4, S334ter-9, P23H-2 and P23H-3), the number of profiles in the DCP were the same as in wild-type controls at P30. In two lines with an intermediate rate of degeneration (S334ter-5 and P23H-1), where only about 25% of the photoreceptors were lost by P15, there was an intermediate number of vascular profiles in the DCP at P30. Thus, a very close relationship between the number of photoreceptors and vessel profiles in the DCP during its development exists in the transgenic rats, and the loss of photoreceptors results in the failure or inhibition of the DCP to develop. Several mechanisms may explain this relationship including changes in the level of physiological oxygen tension or alteration in the release of angiogenic factors that normally drive vessel development. Analysis of older transgenic retinas up to 1 year of age revealed that (1) vascular profiles are lost from the DCP in essentially all lines once fewer than about 30-33% of photoreceptors remain; (2) in those lines where the DCP essentially did not develop (S334ter-7 and S334ter-3), the effect of photoreceptor absence was permanent, and there was no late vascularization of the DCP; (3) the number of capillary profiles in the SP remained no different from controls in any of the lines, despite long-standing loss of photoreceptors; and (4) neovascularization of the RPE by retinal capillaries occurred with a latency of 60-180 days after the loss of photoreceptors, except in S334ter-7 rats, where neovascularization essentially did not occur. Analysis of RCS rats was carried out for comparison.

  19. Ultraviolet A photosensitivity profile of dexchlorpheniramine maleate and promethazine-based creams: Anti-inflammatory, antihistaminic, and skin barrier protection properties.

    PubMed

    Facchini, Gustavo; Eberlin, Samara; Clerici, Stefano Piatto; Alves Pinheiro, Ana Lucia Tabarini; Costa, Adilson

    2017-12-01

    Unwanted side effects such as dryness, hypersensitivity, and cutaneous photosensitivity are challenge for adherence and therapeutical success for patients using treatments for inflammatory and allergic skin response. In this study, we compared the effects of two dermatological formulations, which are used in inflammatory and/or allergic skin conditions: dexchlorpheniramine maleate (DCP; 10 mg/g) and promethazine (PTZ; 20 mg/g). We evaluated both formulations for phototoxicity potential, skin irritation, anti-inflammatory and antihistaminic abilities, and skin barrier repair in vitro and ex vivo using the standard OECD test guideline n° 432, the ECVAM protocol n° 78, and cultured skin explants from a healthy patient. Ultraviolet A was chosen as exogenous agent to induce allergic and inflammatory response. Both PTZ and DCP promoted increases in interleukin-1 (IL-1) synthesis in response to ultraviolet A (UVA) radiation compared to control. However, the increase observed with PTZ was significantly greater than the DCP, indicating that the latter has a lower irritant potential. DCP also demonstrated a protective effect on UVA-induced leukotriene B4 and nuclear factor kappa B (NF-κB) synthesis. Conversely, PTZ demonstrates more robust UVA antihistaminic activity. Likewise, PTZ promoted a significantly greater increase in the production of involucrin and keratin 14, both associated with protective skin barrier property. In conclusion, these data suggest possible diverging UVA response mechanisms of DCP and PTZ, which gives greater insight into the contrasting photosensitizing potential between DCP and PTZ observed in the patients. © 2017 Wiley Periodicals, Inc.

  20. Reinforcement effect of poly(butylene succinate) (PBS)-grafted cellulose nanocrystal on toughened PBS/polylactic acid blends.

    PubMed

    Zhang, Xuzhen; Zhang, Yong

    2016-04-20

    Poly(butylene succinate) (PBS)/polylactic acid (PLA) blends modified with dicumyl peroxide (DCP) were reinforced by PBS-g-cellulose nanocrystal (CNC) through melt mixing. PBS-g-CNC was prepared through in situ polymerization and its structure was confirmed by FTIR, (13)C NMR, XPS and GPC analysis after saponification. The morphological analysis of PBS/PLA/PBS-g-CNC composites before and after etched by CH2Cl2 shows that the addition of DCP and PBS-g-CNC could decrease the size of PBS as a dispersed phase in PLA matrix and improve the dispersion of PBS-g-CNC in both PBS and PLA phases, which could affect the crystallization and mechanical properties of composites. The crystallinity of PLA α'-phase crystal in PBS/PLA/PBS-g-CNC composites is increased obviously by the addition of PBS-g-CNC, leading to an increase of the crystallinity of the composites. PBS/PLA blends modified by DCP have high Notched Izod impact strength and moduli, and the values are increased by the addition of PBS-g-CNC. Both storage modulus and glass translation temperature of PBS/PLA blend are increased by DCP and PBS-g-CNC, which is proved by DMA results, showing a weak molecular segment mobility of PBS/PLA matrix. The addition of DCP decreases the crystallization temperature and crystallinity of PBS/PLA composite, but increases the thermal stability of composites, mostly because of the crosslink effect of DCP on PBS/PLA matrix. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Retrospective review of diphencyprone in the treatment of alopecia areata.

    PubMed

    Lamb, R C; Young, D; Holmes, S

    2016-06-01

    Contact immunotherapy with diphencyprone (DCP) is used to treat alopecia areata (AA). Its reported efficacy is variable, and individual response cannot be predicted. To identify patient and treatment course variables that may affect treatment outcome, and to review DCP service to identify potential areas for development and improvement. This was a retrospective review of a DCP service over a 20-year period (1991-2010). Complete data was available for 205 treatment courses, and 162 (79%) treatment courses were completed for 133 patients. Overall, 72.2% (96/133) of patients had some hair regrowth (any grade). In 15.8% of cases (21/133), response was > 90% regrowth. However, 27.1% (36/133) had no response. We found that extent of alopecia at baseline and duration of disease were statistically significant when comparing patients with an optimal outcome to those without (P < 0.05). In contrast to other reports, atopy, age at onset and nail dystrophy were not statistically significant. For patients receiving more than one course, response to DCP treatment was broadly consistent. Extent of alopecia at baseline and duration of disease are important factors in predicting response. Our results suggest that atopy should not be considered a predictor of poor outcome with respect to DCP treatment. A need for improved data collection, particularly regarding longer-term outcomes, was identified. The role of maintenance therapy requires objective assessment. Opportunities for DCP self-administration by patients should be explored. Limitations of this study include the retrospective nature of the review and lack of long-term follow-up data. © 2015 British Association of Dermatologists.

  2. Bi-directionally draining pore fluid extraction vessel

    DOEpatents

    Prizio, Joseph; Ritt, Alexander; Mower, Timothy E.; Rodine, Lonn

    1991-01-01

    The invention is used to extract pore fluid from porous solids through a combination of mechanical compression and inert-gas injection and comprises a piston for axially compressing samples to force water out, and top and bottom drainage plates for capturing the exuded water and using inert gas to force water to exit when the limits of mechanical compression have been reached.

  3. Rheology of the lithosphere and the folding caused by horizontal compression

    NASA Astrophysics Data System (ADS)

    Birger, B. I.

    2015-05-01

    The laboratory tests of rock specimens show that transient creep, at which deformations increase with time whereas strain rate decreases occurs when creep strains are sufficiently small. Since plate tectonics only permits small deformations in the lithospheric plates, the creep of the lithosphere is transient (non-steady-state). In this work, we study how the rheology of the lithosphere that possesses elasticity, brittleness (pseudo-plasticity), and creep affects the folding in the Earth's crust. Folding is caused by horizontal compression that results from the collision between the lithospheric plates. The effective viscosity characterizing the transient creep is lower than in the case of a steady-state creep and depends on the characteristic time of the considered process. The allowance for transient creep gives the distribution of the rheological properties of the horizontally compressed lithosphere in which the upper crust is brittle, whereas the lower crust and mantle lithosphere are dominated by transient creep. It is shown that the flows that arise in the lithosphere due to the instability under horizontal compression and cause folding are small-scale. These flows are concentrated in the upper brittle crust, they determine the short-wave Earth's surface topography, penetrate into the lower, creep-dominated crust to a shallow depth, and do not penetrate into the mantle. Therefore, these flows do not deform the Moho.

  4. The Diaper Change Play: Validation of a New Observational Assessment Tool for Early Triadic Family Interactions in the First Month Postpartum

    PubMed Central

    Rime, Jérôme; Tissot, Hervé; Favez, Nicolas; Watson, Michael; Stadlmayr, Werner

    2018-01-01

    The quality of family relations, observed during mother–father–infant triadic interactions, has been shown to be an important contributor to child social and affective development, beyond the quality of dyadic mother–child, father–child, and marital relationships. Triadic interactions have been well described in families with 3 month olds and older children using the Lausanne Trilogue Play (LTP). Little is known about the development of mother–father–baby interactions in the very 1st weeks postpartum, mostly because no specific observational setting or particular instrument had been designed to cover this age yet. To fill this gap, we adapted the LTP to create a new observational setting, namely the Diaper Change Play (DCP). Interactions are assessed using the Family Alliance Assessment Scales for DCP (FAAS-DCP). We present the validation of the DCP and its coding system, the FAAS-DCP. The three validation studies presented here (44 mother–father–child–triads) involve a sample of parents with 3-week-old infants recruited in two maternity wards (n = 32 and n = 12) in Switzerland. Infants from both sites were all healthy according to their APGAR scores, weight at birth, and scores on the NICU Network Neurobehavioral Scale (NNNS), which was additionally conducted on the twelve infants recruited in one of the maternity ward. Results showed that the “FAAS – DCP” coding system has good psychometric properties, with a good internal consistency and a satisfying reliability among the three independent raters. Finally, the “FAAS-DCP” scores on the interactive dimensions are comparable to the similar dimensions in the FAAS-LTP. The results showed that there is no statistically significant difference on scores between the “FAAS-DCP” and the “FAAS,” which is consistent with previous studies underlying stability in triadic interaction patterns from pregnancy to 18 months. These first results indicated that the DCP is a promising observational setting, able to assess the development of the early family triadic functioning. The DCP and the FAAS-DCP offer to both clinicians and researchers a way to improve the understanding of the establishment of early family functioning as well as to study the young infant’s triangular capacity. Perspectives for future research will be discussed. PMID:29706912

  5. Comparison of impact results for several polymeric composites over a wide range of low impact velocities

    NASA Technical Reports Server (NTRS)

    Poe, C. C., Jr.; Portanova, M. A.; Masters, J. E.; Sankar, B. V.; Jackson, Wade C.

    1991-01-01

    Static indentation, falling weight, and ballistic impact tests were conducted in clamped plates made of AS4/3501-6 and IM7/8551-7 prepreg tape. The transversely isotropic plates were nominally 7-mm thick. Pendulum and ballistic tests were also conducted on simply supported plates braided with Celion 12000 fibers and 3501-6 epoxy. The 20 degree braided plates were about 5-mm thick. The impactors had spherical or hemispherical shapes with a 12.7 mm diameter. Residual compression strength and damage size were measured. For a given kinetic energy, damage size was least for IM7/8551-7 and greatest for the braided material. Strengths varied inversely with damage size. For a given damage size, strength loss as a fraction of original strength was least for the braided material and greatest for AS4/3501-6 and IM7/8551-7. Strength loss for IM7/8551-7 and AS4/3501-6 was nearly equal. No significant differences were noticed between damage sizes and residual compression strengths for the static indentation, falling weight, and ballistic tests of AS4/3501-6 and IM7/8551-7. For the braided material, sizes of damage were significantly less and compression strengths were significantly more for the falling weight tests than for the ballistic tests.

  6. Effect of component compression on the initial performance of an IPV nickel-hydrogen cell

    NASA Technical Reports Server (NTRS)

    Gahn, Randall F.

    1987-01-01

    An experimental method was developed for evaluating the effect of component compression on the charge and discharge voltage characteristics of a 3 1/2 in. diameter boiler plate cell. A standard boiler plate pressure vessel was modified by the addition of a mechanical feedthrough on the bottom of the vessel which permitted different compressions to be applied to the components without disturbing the integrity of the stack. Compression loadings from 0.94 to 27.4 psi were applied by suspending weights from the feedthrough rod. Cell voltages were measured for 0.96-C, 55-min charge and for 1.37-C, 35-min and 2-C, 24-min discharges. An initial change in voltage performance on both charge and discharge as the loading increased was attributed to seating of the components. Subsequent variation of the compression from 2.97 to 27.4 psi caused only minor changes in either the charge or the discharge voltages. Several one month open-circuit voltage stands and 1100 cycles under LEO conditions at the maximum loading have produced no change in performance.

  7. Effect of component compression on the initial performance of an IPV nickel-hydrogen cell. [Individual Pressure Vessel

    NASA Technical Reports Server (NTRS)

    Gahn, Randall F.

    1987-01-01

    An experimental method was developed for evaluating the effect of component compression on the charge and discharge voltage characteristics of a 3 1/2 in. diameter boiler plate cell. A standard boiler plate pressure vessel was modified by the addition of a mechanical feedthrough on the bottom of the vessel which permitted different compressions to be applied to the components without disturbing the integrity of the stack. Compression loadings from 0.94 to 27.4 psi were applied by suspending weights from the feedthrough rod. Cell voltages were measured for 0.96-C, 55-min charge and for 1.37-C, 35-min and 2-C, 24-min discharges. An initial change in voltage performance on both charge and discharge as the loading increased was attributed to seating of the components. Subsequent variation of the compression from 2.97 to 27.4 psi caused only minor changes in either the charge or the discharge voltages. Several one month open-circuit voltage stands and 1100 cycles under LEO conditions at the maximum loading have produced no change in performance.

  8. Turbulent Friction in the Boundary Layer of a Flat Plate in a Two-Dimensional Compressible Flow at High Speeds

    NASA Technical Reports Server (NTRS)

    Frankl, F.; Voishel, V.

    1943-01-01

    In the present report an investigation is made on a flat plate in a two-dimensional compressible flow of the effect of compressibility and heating on the turbulent frictional drag coefficient in the boundary layer of an airfoil or wing radiator. The analysis is based on the Prandtl-Karman theory of the turbulent boundary later and the Stodola-Crocco, theorem on the linear relation between the total energy of the flow and its velocity. Formulas are obtained for the velocity distribution and the frictional drag law in a turbulent boundary later with the compressibility effect and heat transfer taken into account. It is found that with increase of compressibility and temperature at full retardation of the flow (the temperature when the velocity of the flow at a given point is reduced to zero in case of an adiabatic process in the gas) at a constant R (sub x), the frictional drag coefficient C (sub f) decreased, both of these factors acting in the same sense.

  9. Refined Models for an Analysis of Internal and External Buckling Modes of a Monolayer in a Layered Composite

    NASA Astrophysics Data System (ADS)

    Paimushin, V. N.

    2017-11-01

    For an analysis of internal and external buckling modes of a monolayer inside or at the periphery of a layered composite, refined geometrically nonlinear equations are constructed. They are based on modeling the monolayer as a thin plate interacting with binder layers at the points of boundary surfaces. The binder layer is modeled as a transversely soft foundation. It is assumed the foundations, previously compressed in the transverse direction (the first loading stage), have zero displacements of its external boundary surfaces at the second loading stage, but the contact interaction of the plate with foundations occurs without slippage or delamination. The deformation of the plate at a medium flexure is described by geometrically nonlinear relations of the classical plate theory based on the Kirchhoff-Love hypothesis (the first variant) or the refined Timoshenko model with account of the transverse shear and compression (the second variant). The foundation is described by linearized 3D equations of elasticity theory, which are simplified within the framework of the model of a transversely soft layer. Integrating the linearized equations along the transverse coordinate and satisfying the kinematic joining conditions of the plate with foundations, with account of their initial compression in the thickness direction, a system of 2D geometrically nonlinear equations and appropriate boundary conditions are derived. These equations describe the contact interaction between elements of the deformable system. The relations obtained are simplified for the case of a symmetric stacking sequence.

  10. Postbuckling response of long thick plates loaded in compression including higher order transverse shearing effects

    NASA Technical Reports Server (NTRS)

    Stein, Manuel; Sydow, P. Daniel; Librescu, Liviu

    1990-01-01

    Buckling and postbuckling results are presented for compression-loaded simply-supported aluminum plates and composite plates with a symmetric lay-up of thin + or - 45 deg plies composed of many layers. Buckling results for aluminum plates of finite length are given for various length-to-width ratios. Asymptotes to the curves based on buckling results give N(sub xcr) for plates of infinite length. Postbuckling results for plates with transverse shearing flexibility are compared to results from classical theory for various width-to-thickness ratios. Characteristic curves indicating the average longitudinal direct stress resultant as a function of the applied displacements are calculated based on four different theories: Classical von Karman theory using the Kirchoff assumptions, first-order shear deformation theory, higher-order shear deformation theory, and 3-D flexibility theory. Present results indicate that the 3-D flexibility theory gives the lowest buckling loads. The higher-order shear deformation theory has fewer unknowns than the 3-D flexibility theory but does not take into account through-the-thickness effects. The figures presented show that small differences occur in the average longitudinal direct stress resultants from the four theories that are functions of applied end-shortening displacement.

  11. Peroxidase-catalyzed stabilization of 2,4-dichlorophenol in alkali-extracted soils.

    PubMed

    Palomo, Mónica; Bhandari, Alok

    2011-01-01

    Horseradish peroxidase- (HRP) mediated stabilization of phenolic contaminants is a topic of interest due to its potential for remediation of contaminated soils. This study evaluated the sorption of 2,4-dichlorophenol (DCP) and its HRP-mediated stabilization in two alkali-extracted soils. Alkali extraction reduced the soil organic matter (SOM) contents of the geomaterials and enriched the residual SOM with humin C. Sorption of DCP on these sorbents was complete within 1 d. However, most of the sorbed DCP was removed from the geomaterials by water and methanol, suggesting weak solute-sorbent interactions. The addition of HRP resulted in the generation of DCP polymerization products (DPP), which partitioned between the aqueous and solid phases. The DPP phase distribution was rapid and complete within 24 h. Between 70 and 90% of the added DCP was converted to DPP and up to 43% of the initial aqueous phase contaminant was transformed into a residue that was resistant to extraction with methanol. Bound residues of DPP increased with initial aqueous phase solute concentration and remained fairly constant after 7 d of contact. Contaminant stabilization was noted to be high in the humin-mineral geomaterial. Results illustrate that HRP may be effective in stabilizing phenolic contaminants in subsoils that are likely to contain SOM enriched in humin C.

  12. Accounting For Compressibility In Viscous Flow In Pipes

    NASA Technical Reports Server (NTRS)

    Steinle, Frank W.; Gee, Ken; Murthy, Sreedhara V.

    1991-01-01

    Method developed to account for effects of compressibility in viscous flows through long, circular pipes of uniform diameter. Based on approximation of variations in density and velocity across pipe cross section by profile equations developed for boundary-layer flow between flat plates.

  13. Method of increasing the phase stability and the compressive yield strength of uranium-1 to 3 wt. % zirconium alloy

    DOEpatents

    Anderson, Robert C.

    1986-01-01

    A uranium-1 to 3 wt. % zirconium alloy characterized by high strength, high ductility and stable microstructure is fabricated by an improved thermal mechanical process. A homogenous ingot of the alloy which has been reduced in thickness of at least 50% in the two-step forging operation, rolled into a plate with a 75% reduction and then heated in vacuum at a temperature of about 750.degree. to 850.degree. C. and then quenched in water is subjected to further thermal-mechanical operation steps to increase the compressive yield strength approximately 30%, stabilize the microstructure, and decrease the variations in mechanical properties throughout the plate is provided. These thermal-mechanical steps are achieved by cold rolling the quenched plate to reduce the thickness thereof about 8 to 12%, aging the cold rolled plate at a first temperature of about 325.degree. to 375.degree. C. for five to six hours and then aging the plate at a higher temperature ranging from 480.degree. to 500.degree. C. for five to six hours prior to cooling the billet to ambient conditions and sizing the billet or plate into articles provides the desired increase in mechanical properties and phase stability throughout the plate.

  14. Postbuckling Investigations of Piezoelectric Microdevices Considering Damage Effects

    PubMed Central

    Sun, Zhigang; Wang, Xianqiao

    2014-01-01

    Piezoelectric material has been emerging as a popular building block in MEMS devices owing to its unique mechanical and electrical material properties. However, the reliability of MEMS devices under buckling deformation environments remains elusive and needs to be further explored. Based on the Talreja's tensor valued internal state damage variables as well as the Helmhotlz free energy of piezoelectric material, a constitutive model of piezoelectric materials with damage is presented. The Kachanvo damage evolution law under in-plane compressive loads is employed. The model is applied to the specific case of the postbuckling analysis of the piezoelectric plate with damage. Then, adopting von Karman's plate theory, the nonlinear governing equations of the piezoelectric plates with initial geometric deflection including damage effects under in-plane compressive loads are established. By using the finite difference method and the Newmark scheme, the damage evolution for damage accumulation is developed and the finite difference procedure for postbuckling equilibrium path is simultaneously employed. Numerical results show the postbuckling behaviors of initial flat and deflected piezoelectric plates with damage or no damage under different sets of electrical loading conditions. The effects of applied voltage, aspect ratio of plate, thick-span ratio of plate, damage as well as initial geometric deflections on the postbuckling behaviors of the piezoelectric plate are discussed. PMID:24618774

  15. Development of a hybrid chemical/mechanical heat pump

    NASA Technical Reports Server (NTRS)

    Grzyll, Lawrence R.; Silvestri, John J.; Scaringe, Robert P.

    1991-01-01

    The authors present the current development status of a hybrid chemical/mechanical heat pump for low-lift applications. The heat pump provides electronics cooling by evaporating a pure refrigerant from an absorbent/refrigerant mixture in a generator/cold plate. The current development focused on evaluation of absorbent/refrigerant pairs, corrosion testing, pump and compressor design, and electronic cold plate design. Two cycle configurations were considered. The first configuration utilized a standard mechanical compressor and pump. The second cycle configuration investigated pumps and compressors with non-moving parts. An innovative generator/cold plate design is also presented. The development to date shows that this cycle has about the same performance as standard vapor compression heat pumps with standard refrigerants but may have some performance and reliability advantages over vapor compression heat pumps.

  16. A simple accurate chest-compression depth gauge using magnetic coils during cardiopulmonary resuscitation

    NASA Astrophysics Data System (ADS)

    Kandori, Akihiko; Sano, Yuko; Zhang, Yuhua; Tsuji, Toshio

    2015-12-01

    This paper describes a new method for calculating chest compression depth and a simple chest-compression gauge for validating the accuracy of the method. The chest-compression gauge has two plates incorporating two magnetic coils, a spring, and an accelerometer. The coils are located at both ends of the spring, and the accelerometer is set on the bottom plate. Waveforms obtained using the magnetic coils (hereafter, "magnetic waveforms"), which are proportional to compression-force waveforms and the acceleration waveforms were measured at the same time. The weight factor expressing the relationship between the second derivatives of the magnetic waveforms and the measured acceleration waveforms was calculated. An estimated-compression-displacement (depth) waveform was obtained by multiplying the weight factor and the magnetic waveforms. Displacements of two large springs (with similar spring constants) within a thorax and displacements of a cardiopulmonary resuscitation training manikin were measured using the gauge to validate the accuracy of the calculated waveform. A laser-displacement detection system was used to compare the real displacement waveform and the estimated waveform. Intraclass correlation coefficients (ICCs) between the real displacement using the laser system and the estimated displacement waveforms were calculated. The estimated displacement error of the compression depth was within 2 mm (<1 standard deviation). All ICCs (two springs and a manikin) were above 0.85 (0.99 in the case of one of the springs). The developed simple chest-compression gauge, based on a new calculation method, provides an accurate compression depth (estimation error < 2 mm).

  17. Contribution of actin filaments to the global compressive properties of fibroblasts.

    PubMed

    Ujihara, Yoshihiro; Nakamura, Masanori; Miyazaki, Hiroshi; Wada, Shigeo

    2012-10-01

    Actin filaments are often regarded as tension-bearing components. Here, we examined the effects of actin filaments on global compressive properties of cells experimentally and numerically. Fibroblasts were harvested from the patellar tendon of a mature Japanese white rabbit and treated with cytochalasin D to depolymerize the actin filaments. Intact cells and cells with disrupted actin filaments were subjected to the compressive tests. Each floating cell was held between the cantilever and compressive plates and compressed by moving the compressive plate with a linear actuator to obtain a load-deformation curve under quasi-static conditions. The experimental results demonstrated that the initial stiffness of a cell with disrupted actin filaments decreased by 51%. After the experiments, we simulated the compressive test of cells with/without bundles of actin filaments. A bundle of actin filaments was modeled as a tension-bearing component that generates a force based on Hooke's law only when it was elongated. By contrast, if it was shortened, it was assumed to exert no force. The computational results revealed that the alignment of bundles of actin filaments significantly affected the cell stiffness. In addition, the passive reorientation of bundles of actin filaments perpendicular to the compression induced an increase in the resistance to the vertical elongation of a cell and thereby increased the cell stiffness. These results clearly indicated that bundles of actin filaments contribute to the compressive properties of a cell, even if they are tension-bearing components. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Loading Mode and Environment Effects on Surface Profile Characteristics of Martensite Plates in Cu-Based SMAs

    NASA Astrophysics Data System (ADS)

    Suru, Marius-Gabriel; Paraschiv, Adrian-Liviu; Lohan, Nicoleta Monica; Pricop, Bogdan; Ozkal, Burak; Bujoreanu, Leandru-Gheorghe

    2014-07-01

    The present work reports the influence of the loading mode provided during training under constant stress, in bending, applied to lamellar specimens of Cu-Zn-Al shape memory alloys (SMAs). During training, the specimens were bent by a load fastened at their free end, while being martensitic at room temperature and they lifted the load by one-way effect (1WE), during heating up to austenitic field. On cooling to martensite field, the lower concave surface of bent specimens was compressed, and during heating it was elongated, being subjected to a series of tension-compression cycles, during heating-cooling, respectively. Conversely, the upper convex surface of bent specimens was elongated during cooling and compressed during heating, being subjected to compression-tension cycles. Furthermore, 2WE-trained actuators were tested by means of a hydraulic installation where, this time heating-cooling cycles were performed in oil conditions. Considering that the lower concave surface of the specimens was kept in compressed state, while the upper convex surface was kept in elongated state, the study reveals the influence of the two loading modes and environments on the width of martensite plates of the specimens trained under various numbers of cycles. In this purpose, Cu-Zn-Al specimens, trained under 100-300-500 cycles, were prepared and analyzed by atomic force microscopy (AFM) as well as optical and scanning electron microscopy (OM and SEM, respectively). The analysis also included AFM micrographs corroborated with statistical evaluations in order to reveal the effects of loading mode (tension or compression) in different environmental conditions of the specimens, on the surface profile characteristics of martensite plates, revealed by electropolishing.

  19. On the use and potential use of seasonal to decadal climate predictions for decision-making in Europe

    NASA Astrophysics Data System (ADS)

    Soares, Marta Bruno; Dessai, Suraje

    2014-05-01

    The need for climate information to help inform decision-making in sectors susceptible to climate events and impacts is widely recognised. In Europe, developments in the science and models underpinning the study of climate variability and change have led to an increased interest in seasonal to decadal climate predictions (S2DCP). While seasonal climate forecasts are now routinely produced operationally by a number of centres around the world, decadal climate predictions are still in its infancy restricted to the realm of research. Contrary to other regions of the world, where the use of these types of forecasts, particularly at seasonal timescales, has been pursued in recent years due to higher levels of predictability, little is known about the uptake and climate information needs of end-users regarding S2DCP in Europe. To fill this gap we conducted in-depth interviews with experts and decision-makers across a range of European sectors, a workshop with European climate services providers, and a systematic literature review on the use of S2DCP in Europe. This study is part of the EUropean Provision Of Regional Impact Assessment on a Seasonal-to-decadal timescale (EUPORIAS) project which aims to develop semi-operational prototypes of impact prediction systems in Europe on seasonal to decadal timescales. We found that the emerging landscape of users and potential users of S2DCP in Europe is complex and heterogeneous. Differences in S2DCP information needs across and within organisations and sectors are largely underpinned by factors such as the institutional and regulatory context of the organisations, the plethora of activities and decision-making processes involved, the level of expertise and capacity of the users, and the availability of resources within the organisations. In addition, although the use of S2DCP across Europe is still fairly limited, particular sectors such as agriculture, health, energy, water, (re)insurance, and transport are taking the lead on the use of seasonal forecasts. The potential to use decadal predictions across European sectors was also noted although these are currently not used due to the limitations of the science and the experimental nature of existing predictions. Despite the limited use of these types of climate predictions there is a general understanding that information on the uncertainty of such predictions is a fundamental component of S2DCP although approaches for dealing with such uncertainty also tend to differ across organisations. Perceived barriers to the uptake of these types of climate predictions are mainly associated with low skill and reliability of the models but also with other factors such as relevance, usability, and accessibility of S2DCP by end-users. Potential solutions to overcome such barriers include the potential to explore existing 'windows of opportunity' in Europe, improve current understanding of users' needs, and increase accessibility and awareness of users to available S2DCP in Europe. This paper will present findings from our analysis and consider some of the broader issues raised by the emergence of S2DCP for climate services in Europe.

  20. Fukuyoa paulensis gen. et sp. nov., a New Genus for the Globular Species of the Dinoflagellate Gambierdiscus (Dinophyceae)

    PubMed Central

    Gómez, Fernando; Qiu, Dajun; Lopes, Rubens M.; Lin, Senjie

    2015-01-01

    The marine epiphytic dinoflagellate Gambierdiscus is a toxicologically important genus responsible for ciguatera fish poisoning, the principal cause of non-bacterial illness associated with fish consumption. The genus currently contains species exhibiting either globular or anterior-posteriorly compressed morphologies with marked differences in cell shape and plate arrangement. Here we report a third globular, epiphytic and tychoplanktonic species from the coasts of Ubatuba, Brazil. The new species can be distinguished from G. yasumotoi and G. ruetzleri by its broader first apical plate that occupies a larger portion of the epitheca. Accordingly, phylogenetic trees from small subunit (SSU) and large subunit (LSU) ribosomal DNA sequences also showed strongly supported separation of the new species from the G. yasumotoi / G. ruetzleri group albeit with short distance. The molecular phylogenies, which included new sequences of the planktonic species Goniodoma polyedricum, further indicated that the globular species of Gambierdiscus formed a tight clade, clearly separated (with strong bootstrap support) from the clade of lenticular species including the type for Gambierdiscus. The morphological and molecular data in concert support the split of Gambierdiscus sensu lato into two genera. Gambierdiscus sensu stricto should be reserved for the species with lenticular shapes, highly compressed anterioposteriorly, with short-shank fishhook apical pore plate, large 2' plate, low and ascending cingular displacement, and pouch-like sulcal morphology. The new genus name Fukuyoa gen. nov. should be applied to the globular species, slightly laterally compressed, with long-shank fishhook apical pore plate, large 1' plate, greater and descending cingular displacement, and not pouch-like vertically-oriented sulcal morphology. Fukuyoa contains the new species Fukuyoa paulensis gen. et sp. nov., and F. yasumotoi comb. nov. and F. ruetzleri comb. nov. PMID:25831082

  1. Dynamic Material Properties of Orthotropic Polymer and Molybdenum for Use in Next Generation Composite Armor Concept?

    DTIC Science & Technology

    2011-06-01

    1. Shock Compression Experimental Techniques ...............................22 a. Target...3 Figure 2. Composite plate (left) shown by Poh defeating Tantalum projectile while armor grade steel (right) failed...entire target buildup used for a shock compression experiment ..................................................................................23 Figure

  2. Biosynthesis of Lipoteichoic Acid in Lactobacillus rhamnosus: Role of DltD in d-Alanylation

    PubMed Central

    Debabov, Dmitri V.; Kiriukhin, Michael Y.; Neuhaus, Francis C.

    2000-01-01

    The dlt operon (dltA to dltD) of Lactobacillus rhamnosus 7469 encodes four proteins responsible for the esterification of lipoteichoic acid (LTA) by d-alanine. These esters play an important role in controlling the net anionic charge of the poly (GroP) moiety of LTA. dltA and dltC encode the d-alanine–d-alanyl carrier protein ligase (Dcl) and d-alanyl carrier protein (Dcp), respectively. Whereas the functions of DltA and DltC are defined, the functions of DltB and DltD are unknown. To define the role of DltD, the gene was cloned and sequenced and a mutant was constructed by insertional mutagenesis of dltD from Lactobacillus casei 102S. Permeabilized cells of a dltD::erm mutant lacked the ability to incorporate d-alanine into LTA. This defect was complemented by the expression of DltD from pNZ123/dlt. In in vitro assays, DltD bound Dcp for ligation with d-alanine by Dcl in the presence of ATP. In contrast, the homologue of Dcp, the Escherichia coli acyl carrier protein (ACP), involved in fatty acid biosynthesis, was not bound to DltD and thus was not ligated with d-alanine. DltD also catalyzed the hydrolysis of the mischarged d-alanyl–ACP. The hydrophobic N-terminal sequence of DltD was required for anchoring the protein in the membrane. It is hypothesized that this membrane-associated DltD facilitates the binding of Dcp and Dcl for ligation of Dcp with d-alanine and that the resulting d-alanyl–Dcp is translocated to the primary site of d-alanylation. PMID:10781555

  3. Mobilization of phenol and dichlorophenol in unsaturated soils by non-uniform electrokinetics.

    PubMed

    Luo, Qishi; Zhang, Xihui; Wang, Hui; Qian, Yi

    2005-06-01

    The poor mobility of organic pollutants in contaminated sites frequently results in slow remediation processes. Organics, especially hydrophobic compounds, are generally retained strongly in soil matrix as a result of sorption, sequestration, or even formation into non-aqueous-phase liquids and their mobility is thus greatly reduced. The objective of this study was to evaluate the feasibility of using non-uniform electrokinetic transport processes to enhance the mobility of organic pollutants in unsaturated soils with no injection reagents. Phenol and 2,4-dichlorophenol (2,4-DCP), and kaolin and a natural sandy loam soil were selected as model organics and soils, respectively. The results showed that non-uniform electrokinetics can accelerate the desorption and movement of phenol and 2,4-DCP in unsaturated soils. Electromigration and electroosmotic flow were the main driving forces, and their role in the mobilization of phenol and 2,4-DCP varied with soil pH. The movement of 2,4-DCP in the sandy loam towards the anode (about 1.0 cmd(-1)V(-1)) was 1.0-1.5 cmd(-1)V(-1) slower than that in the kaolin soil, but about 0.5 cmd(-1)V(-1) greater than that of phenol in the sandy loam. When the sandy loam was adjusted to pH 9.3, the movement of phenol and 2,4-DCP towards the anode was about twice and five times faster than that at pH 7.7, respectively. The results also demonstrated that the movement of phenol and 2,4-DCP in soils can be easily controlled by regulating the operational mode of electric field. It is believed that non-uniform electrokinetics has the potential for practical application to in situ remediation of organics-contaminated sites.

  4. Optical coherence tomography angiography discerns preclinical diabetic retinopathy in eyes of patients with type 2 diabetes without clinical diabetic retinopathy.

    PubMed

    Cao, Dan; Yang, Dawei; Huang, Zhongning; Zeng, Yunkao; Wang, Jun; Hu, Yunyan; Zhang, Liang

    2018-05-01

    To investigate changes in retinal vascular plexuses and choriocapillaris in patients with type 2 diabetes mellitus (DM2) without diabetic retinopathy (DR) and healthy controls using optical coherence tomography angiography (OCTA). A total of 71 DM2 and 67 healthy control subjects were included. All subjects underwent OCTA examination (RTVue-XR Avanti; Optovue, Fremont, CA, USA). Average vessel density in superficial capillary plexus (SCP), deep capillary plexus (DCP) and choriocapillaris, parafoveal vessel density in SCP and DCP, FAZ area (mm 2 ) in SCP, microaneurysms and capillary nonperfusion were taken into analysis. Parafoveal vessel density in both SCP and DCP decreased in the eyes without clinical DR compared to normal controls (p < 0.001). Diabetic patients with no signs of DR also had a significant reduction in average vessel density of SCP, DCP and choriocapillaris (p < 0.001, p < 0.001 and p = 0.006, respectively). No significant difference was found in FAZ area of SCP between DM2 eyes and healthy controls (p = 0.253). The average vessel density of SCP and DCP is not correlated with HbA1c or serum creatinine in DM2 patients. Microaneurysms seen in OCTA but not in fundus examination were found in 8 out of the 71 (11.3%) diabetic eyes, and capillary nonperfusion was noted in 18 of 71 diabetic eyes. We demonstrated that OCTA can identify preclinical DR before the manifestation of clinically apparent retinopathy in diabetic eyes. DM2 patients without DR have SCP, DCP and choriocapillaris impairment. Our results suggested that OCTA might be a promising tool for regular screening of diabetic eyes for DR.

  5. An analysis of marketing authorisation applications via the mutual recognition and decentralised procedures in Europe.

    PubMed

    Ebbers, Hans C; Langedijk, Joris; Bouvy, Jacoline C; Hoekman, Jarno; Boon, Wouter P C; de Jong, Jean Philippe; De Bruin, Marie L

    2015-10-01

    The aim of this study is to provide a comprehensive overview of the outcomes of marketing authorisation applications via the mutual recognition and decentralised procedures (MRP/DCP) and assess determinants of licensing failure during CMDh referral procedures. All MRP/DCP procedures to the Co-ordination group for Mutual recognition and Decentralised procedures-human (CMDh) during the period from January 2006 to December 2013 were analysed. Reasons for starting referral procedures were scored. In addition, a survey under pharmaceutical companies was performed to estimate the frequency of licensing failure prior to CMDh referrals. During the study period, 10392 MRP/DCP procedures were finalized. Three hundred seventy-seven (3.6%) resulted in a referral procedure, of which 70 (19%) resulted in licensing failure, defined as refusal or withdrawal of the application. The frequency of CMDh referrals decreased from 14.5% in 2006 to 1.6% in 2013. Of all referrals, 272 (72%) were resolved through consensus within the CMDh, the remaining 105 (28%) were resolved at the level of the CHMP. Most referrals were started because of objections raised about the clinical development program. Study design issues and objections about the demonstration of equivalence were most likely to result in licensing failure. An estimated 11% of all MRP/DCP procedures resulted in licensing failure prior to CMDh referral. Whereas the absolute number of MRP/DCP procedures resulting in a referral has reduced substantially over the past years, no specific time trend could be observed regarding the frequency of referrals resulting in licensing failure. Increased knowledge at the level of companies and regulators has reduced the frequency of late-stage failure of marketing applications via the MRP/DCP.

  6. A Resilience Intervention in African American Adults with Type 2 Diabetes: A Pilot Study of Efficacy

    PubMed Central

    Steinhardt, Mary A.; Mamerow, Madonna M.; Brown, Sharon A.; Jolly, Christopher A.

    2010-01-01

    Purpose The purpose of this pilot study was to determine the feasibility of offering our Diabetes Coaching Program (DCP), adapted for African Americans, in a sample of African American adults with type 2 diabetes. Methods The study utilized a one-group, pretest-posttest design to test the acceptance and potential effectiveness of the DCP. Subjects were a convenience sample of 16 African Americans (8 females; 8 males) with type 2 diabetes; twelve subjects (6 females; 6 males) completed the program. The DCP included four weekly class sessions devoted to resilience education and diabetes self-management, followed by eight biweekly support group meetings. Psychosocial process variables (resilience, coping strategies, diabetes empowerment), and proximal (perceived stress, depressive symptoms, diabetes self-management) and distal outcomes (BMI, fasting blood glucose, HbA1c, lipidemia, blood pressure) were assessed at baseline and six-months post study entry. Qualitative data were collected at eight-months via a focus group conducted to examine the acceptability of the DCP. Results Preliminary paired t-tests indicated statistically significant improvements in diabetes empowerment, diabetes self-management, BMI, HbA1c, total cholesterol, LDL-cholesterol, and systolic and diastolic blood pressure. Medium to large effect sizes were reported. Resilience, perceived stress, fasting blood glucose, and HDL-cholesterol improved, but changes were not statistically significant. Focus group data confirmed that participants held positive opinions regarding the DCP and follow-up support group sessions, although they suggested an increase in program length from 4 to 8 weeks. Conclusions The pilot study documented the feasibility and potential effectiveness of the DCP to enhance diabetes empowerment, diabetes self-management, and reductions in the progression of obesity, type 2 diabetes, and CVD in the African American community. Randomized experimental designs are needed to confirm these findings. PMID:19204102

  7. Implant failure in lower limb long bone diaphyseal fractures at a tertiary hospital in Ile- Ife. Nigeria.

    PubMed

    Esan, O; Ikem, I C; Orimolade, E A; Esan, O T

    2014-06-01

    This included determining aetiology of failure and comparing the failure rate in implant fixations using solid intramedullary nail and DCP. A retrospective study conducted at the Orthopaedic Department, Obafemi Awolowo University Teaching Hospital, Ile-Ife,Nigeria. Records of all operated cases of lower limb long bone diaphyseal fractures including those with failed fixations from August 2006-July 2011 were reviewed. Data retrieved included type of implant used, aetiology and characteristics of Implant failure. Data were analysed using SPSS version 16. Frequency distribution of the variables of interest was done. Difference in failure rate of intramedullary nail versus DCP was tested using chi-square. Statistical significance was inferred at p<0.05. A total of 280 patients were studied out of which two hundred and twenty-one patients had long bone diaphyseal fractures and met inclusion criteria, of which 135 had intramedullary nail fixation and 86 had DCP. The rate of implant failure in intramedullary nail was 1.5% while it was 5.8% in patients with DCP (p=0.113; 0R=4.10; 95% CI=0.65- 43.77). Implant fracture was the commonest type of failure seen (100% versus 60%) and non union was the commonest cause of failure seen (50% versus 40%) in the intramedullary nailing and DCP groups respectively. The likelihood of a failed implant is higher in fixations done with DCP compared with intramedullary nail though the difference was not statistically significant. Commonest reason for failure in both groups was non-union. Findings from this study may guide surgeons in choice of implant in the management of long bone fractures.

  8. Elastic flexure controls magma trajectories and explains the offset of primary volcanic activity upstream of mantle plume axis at la Réunion and Hawaii hotspot islands

    NASA Astrophysics Data System (ADS)

    Gerbault, Muriel; Fontaine, Fabrice J.; Rabinowicz, Michel; Bystricky, Misha

    2017-03-01

    Surface volcanism at la Réunion and Hawaii occurs with an offset of 150-180 km upstream to the plume axis with respect to the plate motion. This striking observation raises questions about the forcing of plume-lithosphere thermo-mechanical interactions on melt trajectories beneath these islands. Based on visco-elasto-plastic numerical models handled at kilometric resolution, we propose to explain this offset by the development of compressional stresses at the base of the lithosphere, that result from elastic plate bending above the upward load exerted by the plume head. This horizontal compression adopts a disc shape centered around the plume axis: (i) it is 20 km thick, (ii) it has a 150 km radius, (iii) it lays at the base of the elastic part of the lithosphere, i.e., around ∼50-70 km depth where the temperature varies from ∼600 °C to ∼750 °C, (iv) it lasts for 5 to 10 My in an oceanic plate of age greater than 70 My, and (vi) it is controlled by the visco-elastic relaxation time at ∼50-70 km depth. This period of time exceeds the time during which both the Somalian/East-African and Pacific plates drift over the Reunion and Hawaii plumes, respectively. This indicates that this basal compression is actually a persistent feature. It is inferred that the buoyant melts percolating in the plume head pond below this zone of compression and eventually spread laterally until the most compressive principal elastic stresses reverse to the vertical, i.e., ∼150 km away from the plume head. There, melts propagate through dikes upwards to ∼35 km depth, where the plate curvature reverses and ambient compression diminishes. This 30-35 km depth may thus host a magmatic reservoir where melts transported by dykes pond. Only after further magmatic differentiation can dykes resume their ascension up to the surface and begin forming a volcanic edifice. As the volcano grows because of melt accumulation at the top of the plate, the lithosphere is flexed downwards, inducing extra tensile stress at 30-35 km depth and compression at ∼15 km depth (induced by the edifice load). It implies that now the melts pond at ∼15 km and form another magmatic reservoir lying just underneath the crust. These processes explain the ponding of primary (shield) melts at ∼35 km and ∼15 km depths as recorded below La Reunion, Mauritius or Hawaii volcanoes, all shifted by ∼150 km with respect to the plume axis.

  9. Comparative evaluation of subgrade resilient modulus from non-destructive, in-situ, and laboratory methods.

    DOT National Transportation Integrated Search

    2007-08-01

    Field and laboratory testing programs were conducted to develop models that predict the resilient modulus of subgrade soils from : the test results of DCP, CIMCPT, FWD, Dynaflect, and soil properties. The field testing program included DCP, CIMCPT, F...

  10. Liver Full Reference Set Application: Hiro Yamada - Wako (2011) — EDRN Public Portal

    Cancer.gov

    Wako has received new 510(k) clearance for Lens culinaris agglutinin-reactive fraction of alpha-fetoprotein (AFP-L3) and Des-gamma-carboxy prothrombin (DCP) tests on an innovative μTASWako i30 analyzer from FDA. The AFP-L3 and DCP assayed on an older platform LiBASys have been cleared with indication of use for risk assessment of hepatocellular carcinoma (HCC) in patient at risk for the liver malignancy. Wako believes that early detection of HCC is critical for improving HCC patient outcome. Therefore, Wako is currently seeking collaborative opportunities to retrospectively measure clinical samples using the AFP-L3 and DCP for further determining of effectiveness of the HCC biomarkers in early detection which are collected prospectively during HCC surveillance. The Reference Sample Set in the EDRN biorepository are well characterized and studied. Access to these samples would allow Wako to quickly determine the clinical effectiveness of AFP-L3 and DCP in detecting early HCC

  11. Stabilization of enzymatically polymerized phenolic chemicals in a model soil organic matter-free geomaterial.

    PubMed

    Palomo, Mónica; Bhandari, Alok

    2012-01-01

    A variety of remediation methods, including contaminant transformation by peroxidase-mediated oxidative polymerization, have been proposed to manage soils and groundwater contaminated with chlorinated phenols. Phenol stabilization has been successfully observed during cross polymerization between phenolic polymers and soil organic matter (SOM) for soils with SOM >3%. This study evaluates peroxidase-mediated transformation and removal of 2,4-dichlorophenol (DCP) from an aqueous phase in contact with a natural geomaterial modified to contain negligible (<0.3%) SOM. The results are compared with those for soils with higher SOM. The SOM-free sorbent was generated by removing SOM using a NaOCl oxidation. When horseradish peroxidase (HRP) was used to induce polymerization of DCP, the soil-water phase distribution relationship (PDR) of DCP polymerization products (DPP) was complete within 1 d and PDRs did not significantly change over the 28 d of study. The conversion of DCP to DPP was close to 95% efficient. Extractable solute consisted entirely of DPP with 5% or less of unreacted DCP. The aqueous extractability of DPP from SOM-free geomaterial decreased at longer contact times and at smaller residual aqueous concentrations of DPP. DCP stabilization appeared to have resulted from a combination of sorption, precipitation, and ligand exchange between oligomeric products and the exposed mineral surfaces. Modification of the mineral surface through coverage with DPP enhanced the time-dependent retention of the oligomers. DPP stabilization in SOM-free geomaterial was comparable with that reported in the literature with soil containing SOM contents >1%. Results from this study suggest that the effectiveness of HRP-mediated stabilization of phenolic compounds not only depends on the cross-coupling with SOM, but also on the modification of the surface of the sorbent that can augment affinity with oligomers and enhance stabilization. Coverage of the mineral surface by phenolic oligomers may be analogous to SOM that can potentially sorb other xenobiotics. HRP- mediated reactions can be used to stabilize DCP associated with low SOM mineral soils or aquifer media, thereby restricting the transport of phenolic contaminants in the soil environment. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  12. Effects of dietary inclusion of citrus pulp and rockrose soft stems and leaves on lamb meat quality and fatty acid composition.

    PubMed

    Francisco, A; Alves, S P; Portugal, P V; Dentinho, M T; Jerónimo, E; Sengo, S; Almeida, J; Bressan, M C; Pires, V M R; Alfaia, C M; Prates, J A M; Bessa, R J B; Santos-Silva, J

    2018-04-01

    Meat from lambs finished with high-starch diets often contains low concentration of vaccenic (t11-18:1) and rumenic (c9,t11-18:2) acids and high concentration of t10-18:1. We hypothesized that replacing cereals by dehydrated citrus pulp (DCP) and the inclusion of tanniferous feed sources in oil supplemented diets might reduce the accumulation of t10-18:1 and increase the t11-18:1 and c9,t11-18:2 in lamb meat, without affecting the productive performance. In total, 32 lambs were assigned to four diets which combine two factors: basal diet (BD) (cereals v. DCP) and Cistus ladanifer (CL) (0 v. 150 g/kg dry matter). Feed intake, average daily weight gain and carcass traits were not affected by treatments, except for dressing percentage that was reduced with DCP (P=0.046). Both DCP and C. ladanifer reduced tenderness and juiciness of meat, and C. ladanifer also reduced (P0.05) by diets. However, DCP increased the proportions of odd-chain FA (P=0.005) and several minor biohydrogenation (BH) intermediates in meat lipids. C. ladanifer had few effects on meat FA profile. The proportions of t11-18:1 and c9,t11-18:2 were high in all diets (5.4% and 1.5% of total FA, respectively) and were not influenced by the treatments. Basal diet and CL showed some significant interactions concerning FA composition of intramuscular fat. In diets without C. ladanifer, replacement of cereals by DCP increased the 18:0 (P<0.05) and decreased t10,c12-18:2 (P<0.05), t10-18:1 (P<0.10) and t10-/t11-18:1 ratio (P<0.10) with a large reduction of the individual variation for t10-18:1 and of t10-/t11-18:1 ratio. Combined with cereals, C. ladanifer increased 18:0 and reduced the BH intermediates in meat. Replacement of cereals by DCP seems to promote a more predictable FA profile in lamb meat, reducing the risk of t10-shifted BH pathways in the rumen.

  13. Incorporation of 210Pb and 210Po to Poultry through the Addition of Dicalcium Phosphate (DCP) to the Diet

    NASA Astrophysics Data System (ADS)

    Casacuberta, N.; Masqué, P.; Garcia-Orellana, J.; Gasa, J.; Anguita, M.

    2008-08-01

    Due to the replacement of calcium by uranium in the phosphorite, sedimentary phosphate rock contains high concentrations of 238U (i.e. from 1500 Bqṡkg-1 in Morocco to 4000 Bqṡkg-1 in Tanzania ores). Dicalcium Phosphate (DCP) is produced by the wet acid digestion of the phosphorite, and is used as a source of calcium and phosphorus for livestock feed supplement. If the phosphorite acid digestion is made with hydrochloric acid, DCP may present specific activities of about 103 Bqṡkg-1 of 238U and some of its decay chain daughters. In particular, due to its radiological implications, the presence of 210Pb and 210Po in DCP is of special relevance. The aim of this work was to investigate the potential incorporation of these radionuclides to poultry through its diet. Three different diets were therefore prepared with different contents of both DCP and 210Pb and 210Po. Diet A was used as a blank, and had a 2.5% in weight of monocalcium phosphate (MCP); diet B, with a 5% in weight of DCP; and diet C, with a 2.5% of DCP. Concentrations of 210Pb were 0.93, 101.4 and 51.2 Bqṡkg-1; whereas concentrations of 210Po were 0.92, 74 and 36 Bqṡkg-1 of food for diets A, B and C, respectively. Accumulation of 210Pb and 210Po was analysed at several times during poultry growth in samples of bone, liver, kidney, muscle, excrements as well as entire animals, with a total of 30 broilers fed with the 3 different diets. Results showed clear enhancements in the accumulation of both 210Pb and 210Po in chicken for diets B and C, and in particular in liver and bone. However, total accumulation of radionuclides in chicken, and especially in edible parts, is low compared to its expulsion through excrements. These results are interpreted in terms of the potential dose through consumption of chicken.

  14. Bipolar battery construction

    NASA Technical Reports Server (NTRS)

    Edwards, Dean B. (Inventor); Rippel, Wally E. (Inventor)

    1981-01-01

    A lightweight, bipolar battery construction for lead acid batteries in which a plurality of thin, rigid, biplates each comprise a graphite fiber thermoplastic composition in conductive relation to lead stripes plated on opposite flat surfaces of the plates, and wherein a plurality of nonconductive thermoplastic separator plates support resilient yieldable porous glass mats in which active material is carried, the biplates and separator plates with active material being contained and maintained in stacked assembly by axial compression of the stacked assembly. A method of assembling such a bipolar battery construction.

  15. Comparative studies on crosslinked and uncrosslinked natural rubber biodegradation by Pseudomonas sp.

    PubMed

    Roy, Ram Vinod; Das, Mithu; Banerjee, Rintu; Bhowmick, Anil K

    2006-12-01

    A comparative study on biodegradation of di-cumyl peroxide (DCP) crosslinked and uncrosslinked natural rubber by Pseudomonas sp. was carried out. Decrease in organic carbon content along with the changes in tensile strength of the treated rubber, both DCP crosslinked and uncrosslinked natural rubber, indicated rubber hydrocarbon utilization by the Pseudomonas sp. A decrease in 60.88% MPa and 41.66% MPa was observed after five month's old treated uncrosslinked natural rubber and DCP crosslinked rubber, respectively. Biodegradation was more pronounced in natural uncrosslinked rubber, which was further confirmed by the formation of aldehydic compounds with decrease in CH2 stretching frequencies.

  16. Studies on morphology of Langmuir-Blodgett films of stearic acid deposited with different orientation of substrates with respect to compression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choudhary, Keerti; Manjuladevi, V.; Gupta, R. K., E-mail: raj@pilani.bits-pilani.ac.in

    2016-05-06

    The Langmuir monolayer at an air-water interface shows remarkably different surface pressure – area isotherm, when measured with the surface normal of a Wilhemly plate parallel or perpendicular to the direction of compression of the monolayer. Such difference arises due to difference in stress exerted by the monolayer on the plate in different direction. In this article, we report the effect of changing the direction of substrate normal with respect to the compression of the monolayer during Langmuir-Blodgett (LB) film deposition on the morphology of the films. The morphology of the LB film of stearic acid was studied using anmore » atomic force microscope (AFM). The morphology of the LB films was found to be different due to difference in the stress in different directions.« less

  17. Compression member response of steel angle on truss structure with variation of single and double sections

    NASA Astrophysics Data System (ADS)

    Panjaitan, Arief; Hasibuan, Purwandy

    2018-05-01

    Implementation of an axial compression load on the steel angle can be found at the various structure such as truss system on telecommunication tower. For telecommunication tower, steel angle section can be suggested as an alternative solution due to its assembling easiness as well as its strength. But, antennas and microwaves installation that keep increases every time on this structure demand reinforcement on each leg of the tower structure. One solution suggested is reinforcement with increasing areas section capacity, where tower leg consisted of single angle section will be reinforced to be double angle section. Regarding this case, this research discussed the behavior of two types of steel angle section: single angle of L.30.30.3 and double angles of 2L.30.30.3. These two sections were designed identically in length (103 cm) and tested by axial compression load. At the first step, compression member together with tension member was formed to be a truss system, where compression and tension member were met at a joint plate. Schematic loading was implemented by giving tension loading on the joint plate until failure of specimens. Experimental work findings showed that implementing double angle sections (103 cm) significantly increased compression capacity of steel angle section up to 118 %.

  18. Method of producing exfoliated graphite composite compositions for fuel cell flow field plates

    DOEpatents

    Zhamu, Aruna; Shi, Jinjun; Guo, Jiusheng; Jang, Bor Z

    2014-04-08

    A method of producing an electrically conductive composite composition, which is particularly useful for fuel cell bipolar plate applications. The method comprises: (a) providing a supply of expandable graphite powder; (b) providing a supply of a non-expandable powder component comprising a binder or matrix material; (c) blending the expandable graphite with the non-expandable powder component to form a powder mixture wherein the non-expandable powder component is in the amount of between 3% and 60% by weight based on the total weight of the powder mixture; (d) exposing the powder mixture to a temperature sufficient for exfoliating the expandable graphite to obtain a compressible mixture comprising expanded graphite worms and the non-expandable component; (e) compressing the compressible mixture at a pressure within the range of from about 5 psi to about 50,000 psi in predetermined directions into predetermined forms of cohered graphite composite compact; and (f) treating the so-formed cohered graphite composite to activate the binder or matrix material thereby promoting adhesion within the compact to produce the desired composite composition. Preferably, the non-expandable powder component further comprises an isotropy-promoting agent such as non-expandable graphite particles. Further preferably, step (e) comprises compressing the mixture in at least two directions. The method leads to composite plates with exceptionally high thickness-direction electrical conductivity.

  19. Operative treatment of intra-articular calcaneal fractures with calcaneal plates and its complications

    PubMed Central

    Rak, Vaclav; Ira, Daniel; Masek, Michal

    2009-01-01

    Background: In a retrospective study we analysed intra-articular calcaneal fracture treatment by comparing results and complications related to fracture stabilization with nonlocking calcaneal plates and locking compression plates. Materials and Methods: We performed 76 osteosynthesis (67 patients) of intra-articular calcaneal fractures using the standard extended lateral approach from February 2004 to October 2007. Forty-two operations using nonlocking calcaneal plates (group A) were performed during the first three years, and 34 calcaneal fractures were stabilized using locking compression plates (group B) in 2007. In the Sanders type IV fractures, reconstruction of the calcaneal shape was attempted. Depending on the type of late complication, we performed subtalar arthroscopy in six cases, arthroscopically assisted subtalar distraction bone block arthrodesis in six cases, and plate removal with lateral-wall decompression in five cases. The patients were evaluated by the AOFAS Ankle-Hindfoot Scale. Results: Wound healing complications were 7/42 (17%) in group A and 1/34 (3%) in group B. No patient had deep osseous infection or foot rebound compartment syndrome. Preoperative size of Böhler's angle correlated with postoperative clinical results in both groups. There were no late complications necessitating corrective procedure or arthroscopy until December 2008 in Group B. All late complications ccurred in Group A. The overall results according to the AOFAS Ankle Hindfoot Scale were good or excellent in 23/42 (55%) in group A and in 30/34 (85%) in group B. Conclusion: Open reduction and internal fixation of intra-articular calcaneal fractures has become a standard surgical method. Fewer complications and better results related to treatment with locking compression plates confirmed in comparison to nonlocking ones were noted for all Sanders types of intra-articular calcaneal fractures. Age and Sanders type IV fractures are not considered to be the contraindications to surgery. PMID:19838350

  20. Improving the de-agglomeration and dissolution of a poorly water soluble drug by decreasing the agglomerate strength of the cohesive powder.

    PubMed

    Allahham, Ayman; Stewart, Peter J; Das, Shyamal C

    2013-11-30

    Influence of ternary, poorly water-soluble components on the agglomerate strength of cohesive indomethacin mixtures during dissolution was studied to explore the relationship between agglomerate strength and extent of de-agglomeration and dissolution of indomethacin (Ind). Dissolution profiles of Ind from 20% Ind-lactose binary mixtures, and ternary mixtures containing additional dibasic calcium phosphate (1% or 10%; DCP), calcium sulphate (10%) and talc (10%) were determined. Agglomerate strength distributions were estimated by Monte Carlo simulation of particle size, work of cohesion and packing fraction distributions. The agglomerate strength of Ind decreased from 1.19 MPa for the binary Ind mixture to 0.84 MPa for 1DCP:20Ind mixture and to 0.42 MPa for 1DCP:2Ind mixture. Both extent of de-agglomeration, demonstrated by the concentration of the dispersed indomethacin distribution, and extent of dispersion, demonstrated by the particle size of the dispersed indomethacin, were in descending order of 1DCP:2Ind>1DCP:20Ind>binary Ind. The addition of calcium sulphate dihydrate and talc also reduced the agglomerate strength and improved de-agglomeration and dispersion of indomethacin. While not definitively causal, the improved de-agglomeration and dispersion of a poorly water soluble drug by poorly water soluble components was related to the agglomerate strength of the cohesive matrix during dissolution. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Toxicant inhibition in activated sludge: fractionation of the physiological status of bacteria.

    PubMed

    Foladori, P; Bruni, L; Tamburini, S

    2014-09-15

    In wastewater treatment plants the sensitivity of activated sludge to a toxicant depends on the toxicity test chosen, and thus the use of more than one test is suggested. The physiological status of bacteria in response to toxicants was analysed by flow cytometry to distinguish intact, permeabilised, active cells and cells disrupted. Results were compared with respirometry and bioluminescence bioassay (Vibrio fischeri). 3,5-Dichlorophenol (DCP) was used as reference xenobiotic. DCP has a strong effect on cellular integrity, causing an increase in permeabilised and disrupted cells. A reduction of 44-80% of intact cells with 6-30 mgDCP/L for 5h was found. Inhibition of active cells was 25-49%, at 6-30 mgDCP/L for 5h. The bioluminescence bioassay resulted oversensitive to DCP compared to tests based on activated sludge, while oxygen uptake rate was affected similarly to intact cells measured by flow cytometry. Landfill leachate was tested: a detrimental impact on both cellular integrity and enzymatic activity was observed. Reduction of intact cells and active cells was by 32% and 61% respectively after addition of 50% (v/v) of leachate for 5h. The flow cytometry analysis proposed here might be widely applicable in the monitoring of various toxicants and in other aquatic biosystems. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Cyanidin-3-O-Glucoside Protects against 1,3-Dichloro-2-Propanol-Induced Reduction of Progesterone by Up-regulation of Steroidogenic Enzymes and cAMP Level in Leydig Cells

    PubMed Central

    Sun, Jianxia; Xu, Wei; Zhu, Cuijuan; Hu, Yunfeng; Jiang, Xinwei; Ou, Shiyi; Su, Zhijian; Huang, Yadong; Jiao, Rui; Bai, Weibin

    2016-01-01

    1,3-Dichloro-2-propanol (1,3-DCP) is a food processing contaminant and has been shown to perturb male reproductive function. Cyanidin-3-O-glucoside (C3G), an anthocyanin antioxidant, is reported to have protective effects on many organs. However, it remains unclear whether C3G protects against chemical-induced reproductive toxicity. The present study was therefore to investigate the intervention of C3G on 1,3-DCP-induced reproductive toxicity in R2C Leydig cells. Results demonstrated that C3G inhibited the 1,3-DCP-induced cytotoxicity and cell shape damage with the effective doses being ranging from 10 to 40 μmol/L. In addition, 1,3-DCP (2 mmol/L) exposure significantly increased the ROS level and mitochondrial membrane potential damage ratio, leading to a decrease in progesterone production, while C3G intervention reduced the ROS level, and increased the progesterone production after 24 h treatment. Most importantly, C3G intervention could up-regulate the cyclic adenosine monophosphate (cAMP) level and protein expression of steroidogenic acute regulatory protein and 3β-hydroxysteroid dehydrogenase. It was concluded that C3G is effective in reducing 1,3-DCP-induced reproductive toxicity via activating steroidogenic enzymes and cAMP level. PMID:27867356

  3. Concise and Efficient Fluorescent Probe via an Intromolecular Charge Transfer for the Chemical Warfare Agent Mimic Diethylchlorophosphate Vapor Detection.

    PubMed

    Yao, Junjun; Fu, Yanyan; Xu, Wei; Fan, Tianchi; Gao, Yixun; He, Qingguo; Zhu, Defeng; Cao, Huimin; Cheng, Jiangong

    2016-02-16

    Sarin, used as chemical warfare agents (CWAs) for terrorist attacks, can induce a number of virulent effects. Therefore, countermeasures which could realize robust and convenient detection of sarin are in exigent need. A concise charge-transfer colorimetric and fluorescent probe (4-(6-(tert-butyl)pyridine-2-yl)-N,N-diphenylaniline, TBPY-TPA) that could be capable of real-time and on-site monitoring of DCP vapor was reported in this contribution. Upon contact with DCP, the emission band red-shifted from 410 to 522 nm upon exposure to DCP vapor. And the quenching rate of TBPY-TPA reached up to 98% within 25 s. Chemical substances such as acetic acid (HAc), dimethyl methylphosphonate (DMMP), pinacolyl methylphosphonate (PAMP), and triethyl phosphate (TEP) do not interfere with the detection. A detection limit for DCP down to 2.6 ppb level is remarkably achieved which is below the Immediately Dangerous to Life or Health concentration. NMR data suggested that a transformation of the pyridine group into pyridinium salt via a cascade reaction is responsible for the sensing process which induced the dramatic fluorescent red shift. All of these data suggest TBPY-TPA is a promising fluorescent sensor for a rapid, simple, and low-cost method for DCP detection, which could be easy to prepare as a portable chemosensor kit for its practical application in real-time and on-site monitoring.

  4. Electronic thermal sensor and Data Collection Platform technology: Part 5 in Thermal surveillance of active volcanoes using the Landsat-1 Data Collection System

    USGS Publications Warehouse

    Preble, Duane M.; Friedman, Jules D.; Frank, David

    1976-01-01

    Five Data Collection Platforms (DCP) were integrated electronically with thermall sensing systems, emplaced and operated in an analog mode at selected thermally significant volcanic and geothermal sites. The DCP's transmitted 3260 messages comprising 26,080 ambient, surface, and near-surface temperature records at an accuracy of ±1.15 °C for 1121 instrument days between November 14, 1972 and April 17, 1974. In harsh, windy, high-altitude volcanic environments the DCP functioned best with a small dipole antenna. Sixteen kg of alkaline batteries provided a viable power supply for the DCP systems, operated at a low-duty cycle, for 5 to 8 months. A proposed solar power supply system would lengthen the period of unattended operation of the system considerably. Special methods of data handling such as data storage via a proposed memory system would increase the significance of the twice-daily data reception enabling the DCP's to record full diurnal-temperature cycles at volcanic or geothermal sites. Refinements in the temperature-monitoring system designed and operated in experiment SR 251 included a backup system consisting of a multipoint temperature scanner, a servo mechanism and an analog-to-digital recorder. Improvements were made in temperature-probe design and in construction of corrosion-resistant seals by use of a hydrofluoric-acid-etching technique.

  5. Bioelectrochemical biosensor for water toxicity detection: generation of dual signals for electrochemical assay confirmation.

    PubMed

    Yang, Yuan; Wang, Yan-Zhai; Fang, Zhen; Yu, Yang-Yang; Yong, Yang-Chun

    2018-02-01

    Toxicity assessment of water is of great important to the safety of human health and to social security because of more and more toxic compounds that are spilled into the aquatic environment. Therefore, the development of fast and reliable toxicity assessment methods is of great interest and attracts much attention. In this study, by using the electrochemical activity of Shewanella oneidensis MR-1 cells as the toxicity indicator, 3,5-dichlorophenol (DCP) as the model toxic compound, a new biosensor for water toxicity assessment was developed. Strikingly, the presence of DCP in the water significantly inhibited the maximum current output of the S. oneidensis MR-1 in a three-electrode system and also retarded the current evolution by the cells. Under the optimized conditions, the maximum current output of the biosensor was proportional to the concentration of DCP up to 30 mg/L. The half maximal inhibitory concentration of DCP determined by this biosensor is about 14.5 mg/L. Furthermore, simultaneous monitoring of the retarded time (Δt) for current generation allowed the identification of another biosensor signal in response to DCP which could be employed to verify the electrochemical result by dual confirmation. Thus, the present study has provided a reliable and promising approach for water quality assessment and risk warning of water toxicity.

  6. Cyanidin-3-O-Glucoside Protects against 1,3-Dichloro-2-Propanol-Induced Reduction of Progesterone by Up-regulation of Steroidogenic Enzymes and cAMP Level in Leydig Cells.

    PubMed

    Sun, Jianxia; Xu, Wei; Zhu, Cuijuan; Hu, Yunfeng; Jiang, Xinwei; Ou, Shiyi; Su, Zhijian; Huang, Yadong; Jiao, Rui; Bai, Weibin

    2016-01-01

    1,3-Dichloro-2-propanol (1,3-DCP) is a food processing contaminant and has been shown to perturb male reproductive function. Cyanidin-3- O -glucoside (C3G), an anthocyanin antioxidant, is reported to have protective effects on many organs. However, it remains unclear whether C3G protects against chemical-induced reproductive toxicity. The present study was therefore to investigate the intervention of C3G on 1,3-DCP-induced reproductive toxicity in R2C Leydig cells. Results demonstrated that C3G inhibited the 1,3-DCP-induced cytotoxicity and cell shape damage with the effective doses being ranging from 10 to 40 μmol/L. In addition, 1,3-DCP (2 mmol/L) exposure significantly increased the ROS level and mitochondrial membrane potential damage ratio, leading to a decrease in progesterone production, while C3G intervention reduced the ROS level, and increased the progesterone production after 24 h treatment. Most importantly, C3G intervention could up-regulate the cyclic adenosine monophosphate (cAMP) level and protein expression of steroidogenic acute regulatory protein and 3β-hydroxysteroid dehydrogenase. It was concluded that C3G is effective in reducing 1,3-DCP-induced reproductive toxicity via activating steroidogenic enzymes and cAMP level.

  7. Effects of in vivo static compressive loading on aggrecan and type II and X collagens in the rat growth plate extracellular matrix.

    PubMed

    Cancel, Mathilde; Grimard, Guy; Thuillard-Crisinel, Delphine; Moldovan, Florina; Villemure, Isabelle

    2009-02-01

    Mechanical loads are essential to normal bone growth, but excessive loads can lead to progressive deformities. In addition, growth plate extracellular matrix remodelling is essential to regulate the normal longitudinal bone growth process and to ensure physiological bone mineralization. In order to investigate the effects of static compression on growth plate extracellular matrix using an in vivo animal model, a loading device was used to precisely apply a compressive stress of 0.2 MPa for two weeks on the seventh caudal vertebra (Cd7) of rats during the pubertal growth spurt. Control, sham and loaded groups were studied. Growth modulation was quantified based on calcein labelling, and three matrix components (type II and X collagens, and aggrecan) were assessed using immunohistochemistry/safranin-O staining. As well, extracellular matrix components and enzymes (MMP-3 and -13, ADAMTS-4 and -5) were studied by qRT-PCR. Loading reduced Cd7 growth by 29% (p<0.05) and 15% (p=0.07) when compared to controls and shams respectively. No significant change could be observed in the mRNA expression of collagens and the proteolytic enzyme MMP-13. However, MMP-3 was significantly increased in the loaded group as compared to the control group (p<0.05). No change was observed in aggrecan and ADAMTS-4 and -5 expression. Low immunostaining for type II and X collagens was observed in 83% of the loaded rats as compared to the control rats. This in vivo study shows that, during pubertal growth spurt, two-week static compression reduced caudal vertebrae growth rates; this mechanical growth modulation occurred with decreased type II and X collagen proteins in the growth plate.

  8. Outcome of locking compression plates in humeral shaft nonunions

    PubMed Central

    Kumar, Malhar N; Ravindranath, V Pratap; Ravishankar, MR

    2013-01-01

    Background: Nonunion of diaphyseal fractures of the humerus are frequently seen in clinical practice (incidence of up to 15% in certain studies) and osteosynthesis using dynamic compression plates, intra medullary nails and Ilizarov fixators have been reported previously. Locking compression plates (LCP) are useful in the presence of disuse osteoporosis, segmental bone loss and cortical defects that preclude strong fixation. We report a prospective followup study of the outcome of the use of LCP for humeral nonunion following failed internal fixation in which implants other than LCP had been used. Materials and Methods: Twenty four patients with nonunion of humeral shaft fractures following failed internal fixation were included in the study. The mean followup period was 3.4 years (range: 2.4 to 5.7 years) and the minimum followup period was 2 years. Mean age of the patients was 41.04 years (range: 24 to 57 years). All 24 patients underwent osteosynthesis using LCP and autologous bone grafting (cortico-cancellous iliac crest graft combined with or without fibular strut graft). Main outcome measurements included radiographic assessment of fracture union and pre and postoperative functional evaluation using the modified Constant and Murley scoring system. Results: 23 out of 24 fractures united following osteosynthesis. Average time to union was 16 weeks (range: 10 to 28 weeks). Complications included delayed union (n = 2), transient radial nerve palsy (n = 2) and persistent nonunion (n = 1). Functional evaluation using the Constant and Murley score showed excellent results in 11, good in 10, fair in two and poor outcome in one patient. Conclusions: Locking compression plating and cancellous bone grafting is a reliable option for achieving union in humeral diaphyseal nonunion with failed previous internal fixation and results in good functional outcome in patients with higher physiological demands. PMID:23682176

  9. The Impact of Nitinol Staples on the Compressive Forces, Contact Area, and Mechanical Properties in Comparison to a Claw Plate and Crossed Screws for the First Tarsometatarsal Arthrodesis.

    PubMed

    Aiyer, Amiethab; Russell, Nicholas A; Pelletier, Matthew H; Myerson, Mark; Walsh, William R

    2016-06-01

    Background The optimal fixation method for the first tarsometatarsal arthrodesis remains controversial. This study aimed to develop a reproducible first tarsometatarsal testing model to evaluate the biomechanical performance of different reconstruction techniques. Methods Crossed screws or a claw plate were compared with a single or double shape memory alloy staple configuration in 20 Sawbones models. Constructs were mechanically tested in 4-point bending to 1, 2, and 3 mm of plantar displacement. The joint contact force and area were measured at time zero, and following 1 and 2 mm of bending. Peak load, stiffness, and plantar gapping were determined. Results Both staple configurations induced a significantly greater contact force and area across the arthrodesis than the crossed screw and claw plate constructs at all measurements. The staple constructs completely recovered their plantar gapping following each test. The claw plate generated the least contact force and area at the joint interface and had significantly greater plantar gapping than all other constructs. The crossed screw constructs were significantly stiffer and had significantly less plantar gapping than the other constructs, but this gapping was not recoverable. Conclusions Crossed screw fixation provides a rigid arthrodesis with limited compression and contact footprint across the joint. Shape memory alloy staples afford dynamic fixation with sustained compression across the arthrodesis. A rigid polyurethane foam model provides an anatomically relevant comparison for evaluating the interface between different fixation techniques. Clinical Relevance The dynamic nature of shape memory alloy staples offers the potential to permit early weight bearing and could be a useful adjunctive device to impart compression across an arthrodesis of the first tarsometatarsal joint. Therapeutic, Level V: Bench testing. © 2015 The Author(s).

  10. Reactive processing of biodegradable polyesters with dicumyl peroxide: A structural, rheological and property study

    NASA Astrophysics Data System (ADS)

    Canale, Philip Louis

    Studies were undertaken to gain an understanding as to the mechanistic, rheological, thermal, and mechanical property effects that can be expected by reactively extruding biodegradable polyesters with dicumyl peroxide (DCP). The two main polymers used were poly(epsilon-caprolactone), (PCL), and proprietary copolyester, Eastar 14766. The reactive extrusions were carried out at 160°C at various DCP levels. The percent branching and type of branching, (tetraor tri-functional), were determined by SEC and by the comparison of branched distributions to statistical models. It was found that PCL quantitatively formed tetra-functional branches while the Eastar 14766 formed a combination of tri- and tetra-functional branch points. The Eastar 14766 was also shown to be more reactive than the PCL, with half as much DCP being required to achieve equivalent amounts of branching. Thermal properties were studied by differential scanning calorimetry. In a multi-phase, upper critical solution temperature (UCST) system, such as Eastar 14766, the branches resulted in a compatiblization effect. This was shown as an increase in the glass transition temperature rising with the DCP level used in the reactive extrusion. The crystallization temperature decreased, and the heat of melting increased as the amount of branching/DCP level increased. The latter was attributed to the lower stereo regularity and/or the lower crystallization rate. The crystallization temperature increase is attributed to increased kinetics required, due to slower phase separation or increased viscosity. Branching/DCP level was shown to have a smaller effect on PCL, with the largest effect being an 11% relative decrease in heat of melting at the highest DCP level. Rheology studies showed that both Eastar 14766 and PCL displayed typical branching behavior with increases in melt elasticity and zero shear viscosity. An estimate of the plateau modulus revealed the entanglement molecular weight for Eastar 14766 to be approximately three times lower than that of PCL. This explained why Eastar 14766 had a larger enhancement in zero shear viscosity and elasticity than PCL. It was also noted, qualitatively, that branching in both materials produced a broadened elastic modulus curve. This was attributed to the difference in the molecular weight/relaxation time relationship between linear and branched materials. Tensile modulus and elongation studies showed PCL to be insensitive to branching. However, studies with Eastar 14766 showed tensile strength and elongation at break to be increased 30 and 10% respectively with branching. Tensile modulus on the other hand, remained relatively unchanged. These effects were attributed to phase changes due to increased compatibilization of the copolymer. A brief study of a 50/50 blend of Eastar 14766 and Poly(lactic acid) with and without DCP showed that the blend with DCP had a similar tensile strength. However, the ultimate elongation increased by 150% and the modulus decreased of 26%. This shows the possible utility of reactive blending with peroxides in order to achieve a higher degree of compatibilization in a blend.

  11. 76 FR 63915 - DCP Midstream, LP; Notice of Application

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-14

    ... application pursuant to Section 7(c) of the Natural Gas Act and Part 157 of the Commission's Regulations, for... diameter pipeline (the LaSalle Residue Line) connecting DCP's new non-jurisdictional natural gas processing... non-jurisdictional gas gathering company having facilities in Texas, Oklahoma, New Mexico, Louisiana...

  12. 76 FR 8725 - Notice of Baseline Filings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-15

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Baseline Filings Enstor Grama Ridge Storage and Docket No. PR10-97-002. Transportation, L.L.C.. EasTrans, LLC Docket No. PR10-30-001. DCP Guadalupe Pipeline, LLC...... Docket No. PR10-31-002. DCP Raptor Pipeline, LLC......... Docket No...

  13. 78 FR 43190 - DCP Midstream, LP; Notice of Application

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-19

    ... capacity of 230 MMcf/day and will be used for transportation of natural gas solely on behalf of DCP without... will either: complete its environmental assessment (EA) and place it into the Commission's public... anticipated date for the Commission staff's issuance of the final environmental impact statement (FEIS) or EA...

  14. Elastic Buckling under Combined Stresses of Flat Plates with Integral Waffle-Like Stiffening

    NASA Technical Reports Server (NTRS)

    Dow, Norris F.; Levin, L. Ross; Troutman, John L.

    1953-01-01

    Theory and experiment were compared and found in good agreement for the elastic Buckling under combined stresses of long flat plates with integral waffle-like stiffening in a variety of configurations. For such flat plates, 45deg waffle stiffening was found to be the most effective of the configurations for the proportions considered over the widest range of combinations of compression and shear.

  15. Elastic Buckling Under Combined Stresses of Flat Plates with Integral Waffle-like Stiffening

    NASA Technical Reports Server (NTRS)

    Dow, Norris F; Levin, L Ross; Troutman, John L

    1954-01-01

    Theory and experiment were compared and found in good agreement for the elastic buckling under combined stresses of long flat plates with integral waffle-like stiffening in a variety of configurations. For such flat plates, 45 degree waffle stiffening was found to be the most effective of the configurations for the proportions considered over the widest range of combinations of compression and shear.

  16. High-Fidelity Numerical Modeling of Compressible Flow

    DTIC Science & Technology

    2015-11-01

    details on these aspects of the implementation were reported in an earlier paper by Poggie.42 C. Flowfield Two flat - plate turbulent boundary layer flows...work investigated flat plate turbulent boundary layer flows. The baseline case was a flow at Mach 2.3, under conditions similar to those employed in...analyzed. The solutions are compared to a spanwise- periodic flat - plate turbulent boundary layer developed at the same conditions and yield similar

  17. Mathematical Identification of Influential Parameters on the Elastic Buckling of Variable Geometry Plate

    PubMed Central

    Tepic, Jovan; Kostelac, Milan

    2013-01-01

    The problem of elastic stability of plates with square, rectangular, and circular holes as well as slotted holes was discussed. The existence of the hole reduces the deformation energy of the plate and it affects the redistribution of stress flow in comparison to a uniform plate which causes a change of the external operation of compressive forces. The distribution of compressive force is defined as the approximate model of plane state of stress. The significant parameters of elastic stability compared to the uniform plate, including the dominant role of the shape, size, and orientation of the hole were identified. Comparative analysis of the shape of the hole was carried out on the data from the literature, which are based on different approaches and methods. Qualitative and quantitative accordance of the results has been found out and it verifies exposed methodology as applicable in the study of the phenomenon of elastic stability. Sensitivity factor is defined that is proportional to the reciprocal value of the buckling coefficient and it is a measure of sensitivity of plate to the existence of the hole. Mechanism of loss of stability is interpreted through the absorption of the external operation, induced by the shape of the hole. PMID:24453821

  18. BUCKO- A BUCKLING ANALYSIS FOR RECTANGULAR PLATES WITH CENTRALLY LOCATED CUTOUTS

    NASA Technical Reports Server (NTRS)

    Nemeth, M. P.

    1994-01-01

    BUCKO is a computer program developed to predict the buckling load of a rectangular compression-loaded orthotropic plate with a centrally located cutout. The plate is assumed to be a balanced, symmetric laminate of uniform thickness. The cutout shape can be elliptical, circular, rectangular, or square. The BUCKO package includes sample data that demonstrates the essence of the program and its ease of usage. BUCKO uses an approximate one-dimensional formulation of the classical two-dimensional buckling problem following the Kantorovich method. The boundary conditions are considered to be simply supported unloaded edges and either clamped or simply supported loaded edges. The plate is loaded in uniaxial compression by either uniformly displacing or uniformly stressing two opposite edges of the plate. The BUCKO analysis consists of two parts: calculation of the inplane stress distribution prior to buckling, and calculation of the plate axial load and displacement at buckling. User input includes plate planform and cutout geometry, plate membrane and bending stiffnesses, finite difference parameters, boundary condition data, and loading data. Results generated by BUCKO are the prebuckling strain energy, inplane stress resultants, buckling mode shape, critical end shortening, and average axial and transverse strains at buckling. BUCKO is written in FORTRAN V for batch execution and has been implemented on a CDC CYBER 170 series computer operating under NOS with a central memory requirement of approximately 343K of 60 bit words. This program was developed in 1984 and was last updated in 1990.

  19. Electromechanical acoustic liner

    NASA Technical Reports Server (NTRS)

    Sheplak, Mark (Inventor); Cattafesta, III, Louis N. (Inventor); Nishida, Toshikazu (Inventor); Horowitz, Stephen Brian (Inventor)

    2007-01-01

    A multi-resonator-based system responsive to acoustic waves includes at least two resonators, each including a bottom plate, side walls secured to the bottom plate, and a top plate disposed on top of the side walls. The top plate includes an orifice so that a portion of an incident acoustical wave compresses gas in the resonators. The bottom plate or the side walls include at least one compliant portion. A reciprocal electromechanical transducer coupled to the compliant portion of each of the resonators forms a first and second transducer/compliant composite. An electrical network is disposed between the reciprocal electromechanical transducer of the first and second resonator.

  20. Buckling mode localization in elastic plates due to misplacement in the stiffener location

    NASA Technical Reports Server (NTRS)

    Elishakoff, I.; Li, Y. W.; Starnes, J. H., Jr.

    1998-01-01

    This paper deals with the buckling of the stiffened plate under uni-axial compression. The direct integration of the governing differential equation is performed and the exact solution to the problem is obtained. As examples, a square plate with single stiffener, and a stiffened three-span, continuous plate are investigated, with special attention given to the influence of stiffener misplacement on the buckling load and mode shape of the plate. It is found that a small misplacement of the stiffeners from the nominal configuration may change the buckling mode from a global one to a highly localized one.

  1. The effects of embedded internal delaminations on composite laminate compression strength; an experimental review

    NASA Technical Reports Server (NTRS)

    Nettles, Alan T.

    1994-01-01

    Delaminations in laminated composite materials can degrade the compressive strength of these materials. Delaminations can form as a result of impact damage or processing flaws. In order to better understand the effects of these delaminations on the compressive behavior of laminated composite plates, programs have been conducted to assess the criticality of prescribed delaminations of known size, shape, and location on the compression strength of laminated composites. A review of these programs is presented along with highlights of pertinent findings from each.

  2. Stress analysis of implant-bone fixation at different fracture angle

    NASA Astrophysics Data System (ADS)

    Izzawati, B.; Daud, R.; Afendi, M.; Majid, MS Abdul; Zain, N. A. M.; Bajuri, Y.

    2017-10-01

    Internal fixation is a mechanism purposed to maintain and protect the reduction of a fracture. Understanding of the fixation stability is necessary to determine parameters influence the mechanical stability and the risk of implant failure. A static structural analysis on a bone fracture fixation was developed to simulate and analyse the biomechanics of a diaphysis shaft fracture with a compression plate and conventional screws. This study aims to determine a critical area of the implant to be fractured based on different implant material and angle of fracture (i.e. 0°, 30° and 45°). Several factors were shown to influence stability to implant after surgical. The stainless steel, (S. S) and Titanium, (Ti) screws experienced the highest stress at 30° fracture angle. The fracture angle had a most significant effect on the conventional screw as compared to the compression plate. The stress was significantly higher in S.S material as compared to Ti material, with concentrated on the 4th screw for all range of fracture angle. It was also noted that the screws closest to the intense concentration stress areas on the compression plate experienced increasing amounts of stress. The highest was observed at the screw thread-head junction.

  3. FE Analysis of Buckling Behavior Caused by Welding in Thin Plates of High Tensile Strength Steel

    NASA Astrophysics Data System (ADS)

    Wang, Jiangchao; Rashed, Sherif; Murakawa, Hidekazu

    2014-12-01

    The target of this study was to investigate buckling behavior during the entire welding process which consists of the heating and the cooling processes. For thin plate structures made of high tensile strength steel, not only residual buckling during or after cooling down but also transient buckling during heating may occur. The thermal elastic plastic FE analysis to investigate welding-induced buckling during the entire welding process is presented. Because of the high yield stress of high tensile strength steel, larger longitudinal compressive thermal stress is produced near the welding line compared with that in the case of carbon steel. Therefore, the plate may buckle due to thermal expansion, before the material nears yielding. During cooling down, the longitudinal compressive thermal stress close to the welding line disappears, and longitudinal tensile residual stress is produced due to contraction. Meanwhile, longitudinal compressive residual stress occurs far from the welding line to balance the tensile stress close to the welding line. This distribution of longitudinal residual stress would change the deformed dish shape of transient buckling into a saddle buckling type when the stress exceeds the critical buckling condition.

  4. Screw fixation versus arthroplasty versus plate fixation for 3-part radial head fractures.

    PubMed

    Wu, P H; Shen, L; Chee, Y H

    2016-04-01

    To compare the outcome following headless compression screw fixation versus radial head arthroplasty versus plate fixation for 3-part Mason types III or IV radial head fracture. Records of 25 men and 16 women aged 21 to 80 (mean, 43.3) years who underwent fixation using 2 to 3 2-mm cannulated headless compression screws (n=16), radial head arthroplasty (n=13), or fixation with a 2-mm Synthes plate (n=12) for 3-part Mason types III or IV radial head and neck fracture were reviewed. Treatment option was decided by the surgeon based on the presence of associated injury, neurovascular deficit, and the Mason classification. Bone union, callus formation, and complications (such as heterotopic ossification, malunion, and nonunion) were assessed by an independent registrar or consultant using radiographs. The Mayo Elbow Performance Score and range of motion were assessed by an independent physiotherapist. The median age of the 3 groups were comparable. Associated injuries were most common in patients with arthroplasty, followed by screw fixation and plate fixation (61.5% vs. 50% vs. 33%, p=0.54). The median time to bone union was shorter after screw fixation than plate fixation (55 vs. 86 days, p=0.05). No patient with screw fixation had nonunion, but 4 patients with plate fixation had nonunion. The 3 groups were comparable in terms of the mean Mayo Elbow Performance Score (p=0.56) and the mean range of motion (p=0.45). The complication rate was highest after plate fixation, followed by screw fixation and arthroplasty (50% vs. 18.8% vs. 15.4%, p=0.048). Excluding 20 patients with associated injuries (8 in screw fixation, 8 in arthroplasty, and 4 in plate fixation), the 3 groups were comparable in terms of the median time to bone union (p=0.109), mean Mayo Elbow Performance Score (p=0.260), mean range of motion (p=0.162), and complication rate (p=0.096). Headless compression screw fixation is a viable option for 3-part radial head fracture. It achieves earlier bone union with fewer complications.

  5. Elevated alpha-fetoprotein: differential diagnosis - hepatocellular carcinoma and other disorders.

    PubMed

    Wong, Robert J; Ahmed, Aijaz; Gish, Robert G

    2015-05-01

    The incidence of cirrhosis-related hepatocellular carcinoma (HCC) is rising. Curative surgical options are available; outcomes are acceptable with early diagnosis. Lens culinaris agglutinin-reactive fraction of alpha-fetoprotein (AFP-L3) and des-gamma-carboxy prothrombin (DCP) are HCC risk markers. A high or increasing serum biomarker level can be predictive of the eventual development of HCC, large tumor size, advanced stage, extrahepatic metastases, portal vein thrombosis, and postoperative HCC recurrence. Based on FDA guidelines for HCC risk assessment, clinicians can consider using either the combination of AFP-L3 with DCP, or the combination of AFP-L3 with AFP and DCP. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Calculation of compressible boundary layer flow about airfoils by a finite element/finite difference method

    NASA Technical Reports Server (NTRS)

    Strong, Stuart L.; Meade, Andrew J., Jr.

    1992-01-01

    Preliminary results are presented of a finite element/finite difference method (semidiscrete Galerkin method) used to calculate compressible boundary layer flow about airfoils, in which the group finite element scheme is applied to the Dorodnitsyn formulation of the boundary layer equations. The semidiscrete Galerkin (SDG) method promises to be fast, accurate and computationally efficient. The SDG method can also be applied to any smoothly connected airfoil shape without modification and possesses the potential capability of calculating boundary layer solutions beyond flow separation. Results are presented for low speed laminar flow past a circular cylinder and past a NACA 0012 airfoil at zero angle of attack at a Mach number of 0.5. Also shown are results for compressible flow past a flat plate for a Mach number range of 0 to 10 and results for incompressible turbulent flow past a flat plate. All numerical solutions assume an attached boundary layer.

  7. Short-wavelength buckling and shear failures for compression-loaded composite laminates. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Shuart, M. J.

    1985-01-01

    The short-wavelength buckling (or the microbuckling) and the interlaminar and inplane shear failures of multi-directional composite laminates loaded in uniaxial compression are investigated. A laminate model is presented that idealizes each lamina. The fibers in the lamina are modeled as a plate, and the matrix in the lamina is modeled as an elastic foundation. The out-of-plane w displacement for each plate is expressed as a trigonometric series in the half-wavelength of the mode shape for laminate short-wavelength buckling. Nonlinear strain-displacement relations are used. The model is applied to symmetric laminates having linear material behavior. The laminates are loaded in uniform end shortening and are simply supported. A linear analysis is used to determine the laminate stress, strain, and mode shape when short-wavelength buckling occurs. The equations for the laminate compressive stress at short-wavelength buckling are dominated by matrix contributions.

  8. 75 FR 9201 - DCP Raptor Pipeline, LLC; Notice of Compliance Filing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-01

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR09-32-002] DCP Raptor... Raptor Pipeline, LLC (Raptor) filed its Statement of Operating Conditions in compliance with the January 27, 2010 Letter Order (January 27th Letter Order) in Docket Nos. PR09-32-000 and PR09-32-001. Raptor...

  9. The Problem with the Delta Cost Project Database

    ERIC Educational Resources Information Center

    Jaquette, Ozan; Parra, Edna

    2016-01-01

    The Integrated Postsecondary Education System (IPEDS) collects data on Title IV institutions. The Delta Cost Project (DCP) integrated data from multiple IPEDS survey components into a public-use longitudinal dataset. The DCP Database was the basis for dozens of journal articles and a series of influential policy reports. Unfortunately, a flaw in…

  10. Sharp organic interface of molecular C60 chains and a pentacene derivative SAM on Au(788): A combined STM & DFT study

    NASA Astrophysics Data System (ADS)

    Wang, Jun; Tang, Jian-Ming; Larson, Amanda M.; Miller, Glen P.; Pohl, Karsten

    2013-12-01

    Controlling the molecular structure of the donor-acceptor interface is essential to overcoming the efficiency bottleneck in organic photovoltaics. We present a study of self-assembled fullerene (C60) molecular chains on perfectly ordered 6,13-dichloropentacene (DCP) monolayers forming on a vicinal Au(788) surface using scanning tunneling microscopy in conjunction with density functional theory calculations. DCP is a novel pentacene derivative optimized for photovoltaic applications. The molecules form a brick-wall patterned centered rectangular lattice with the long axis parallel to the monatomic steps that separate the 3.9 nm wide Au(111) terraces. The strong interaction between the C60 molecules and the gold substrate is well screened by the DCP monolayer. At submonolayer C60 coverage, the fullerene molecules form long parallel chains, 1.1 nm apart, with a rectangular arrangement instead of the expected close-packed configuration along the upper step edges. The perfectly ordered DCP structure is unaffected by the C60 chain formation. The controlled sharp highly-ordered organic interface has the potential to improve the conversion efficiency in organic photovoltaics.

  11. Decapping activators in Saccharomyces cerevisiae act by multiple mechanisms.

    PubMed

    Nissan, Tracy; Rajyaguru, Purusharth; She, Meipei; Song, Haiwei; Parker, Roy

    2010-09-10

    Eukaryotic mRNA degradation often occurs in a process whereby translation initiation is inhibited and the mRNA is targeted for decapping. In yeast cells, Pat1, Scd6, Edc3, and Dhh1 all function to promote decapping by an unknown mechanism(s). We demonstrate that purified Scd6 and a region of Pat1 directly repress translation in vitro by limiting the formation of a stable 48S preinitiation complex. Moreover, while Pat1, Edc3, Dhh1, and Scd6 all bind the decapping enzyme, only Pat1 and Edc3 enhance its activity. We also identify numerous direct interactions between Pat1, Dcp1, Dcp2, Dhh1, Scd6, Edc3, Xrn1, and the Lsm1-7 complex. These observations identify three classes of decapping activators that function to directly repress translation initiation and/or stimulate Dcp1/2. Moreover, Pat1 is identified as critical in mRNA decay by first inhibiting translation initiation, then serving as a scaffold to recruit components of the decapping complex, and finally activating Dcp2. Copyright © 2010 Elsevier Inc. All rights reserved.

  12. Novel Dehalogenase Mechanism for 2,3-Dichloro-1-Propanol Utilization in Pseudomonas putida Strain MC4

    PubMed Central

    Arif, Muhammad Irfan; Samin, Ghufrana; van Leeuwen, Jan G. E.; Oppentocht, Jantien

    2012-01-01

    A Pseudomonas putida strain (MC4) that can utilize 2,3-dichloro-1-propanol (DCP) and several aliphatic haloacids and haloalcohols as sole carbon and energy source for growth was isolated from contaminated soil. Degradation of DCP was found to start with oxidation and concomitant dehalogenation catalyzed by a 72-kDa monomeric protein (DppA) that was isolated from cell lysate. The dppA gene was cloned from a cosmid library and appeared to encode a protein equipped with a signal peptide and that possessed high similarity to quinohemoprotein alcohol dehydrogenases (ADHs), particularly ADH IIB and ADH IIG from Pseudomonas putida HK. This novel dehalogenating dehydrogenase has a broad substrate range, encompassing a number of nonhalogenated alcohols and haloalcohols. With DCP, DppA exhibited a kcat of 17 s−1. 1H nuclear magnetic resonance experiments indicated that DCP oxidation by DppA in the presence of 2,6-dichlorophenolindophenol (DCPIP) and potassium ferricyanide [K3Fe(CN)6] yielded 2-chloroacrolein, which was oxidized to 2-chloroacrylic acid. PMID:22752160

  13. Primary Cilia Modulate IHH Signal Transduction in Response to Hydrostatic Loading of Growth Plate Chondrocytes

    PubMed Central

    Shao, Y, Yvonne Y.; Wang, Lai; Welter, J, Jean F.; Ballock, R. Tracy

    2011-01-01

    Indian Hedgehog (Ihh) is a key component of the regulatory apparatus governing chondrocyte proliferation and differentiation in the growth plate. Recent studies have demonstrated that the primary cilium is the site of Ihh signaling within the cell, and that primary cilia are essential for bone and cartilage formation. Primary cilia are also postulated to act as mechanosensory organelles that transduce mechanical forces acting on the cell into biological signals. In this study, we used a hydrostatic compression system to examine Ihh signal transduction under the influence of mechanical load. Our results demonstrate that hydrostatic compression increased both Ihh gene expression and Ihh-responsive Gli-luciferase activity. These increases were aborted by disrupting the primary cilia structure with chloral hydrate. These results suggest that growth plate chondrocytes respond to hydrostatic loading by increasing Ihh signaling, and that the primary cilium is required for this mechano-biological signal transduction to occur. PMID:21930256

  14. Study on the CO2 electric driven fixed swash plate type compressor for eco-friendly vehicles

    NASA Astrophysics Data System (ADS)

    Nam, Donglim; Kim, Kitae; Lee, Jehie; Kwon, Yunki; Lee, Geonho

    2017-08-01

    The purpose of this study is to experiment and to performance analysis about the electric-driven fixed swash plate compressor using alternate refrigerant(R744). Comprehensive simulation model for an electric driven compressor using CO2 for eco-friendly vehicle is presented. This model consists of compression model and dynamic model. The compression model included valve dynamics, leakage, and heat transfer models. And the dynamic model included frictional loss between piston ring and cylinder wall, frictional loss between shoe and swash plate, frictional loss of bearings, and electric efficiency. Especially, because the efficiency of an electric parts(motor and inverter) in the compressor affects the loss of the compressor, the dynamo test was performed. We made the designed compressor, and tested the performance of the compressor about the variety pressure conditions. Also we compared the performance analysis result and performance test result.

  15. Stacking-sequence optimization for buckling of laminated plates by integer programming

    NASA Technical Reports Server (NTRS)

    Haftka, Raphael T.; Walsh, Joanne L.

    1991-01-01

    Integer-programming formulations for the design of symmetric and balanced laminated plates under biaxial compression are presented. Both maximization of buckling load for a given total thickness and the minimization of total thickness subject to a buckling constraint are formulated. The design variables that define the stacking sequence of the laminate are zero-one integers. It is shown that the formulation results in a linear optimization problem that can be solved on readily available software. This is in contrast to the continuous case, where the design variables are the thicknesses of layers with specified ply orientations, and the optimization problem is nonlinear. Constraints on the stacking sequence such as a limit on the number of contiguous plies of the same orientation and limits on in-plane stiffnesses are easily accommodated. Examples are presented for graphite-epoxy plates under uniaxial and biaxial compression using a commercial software package based on the branch-and-bound algorithm.

  16. Surface properties of Indonesian-made narrow dynamic compression plates.

    PubMed

    Dewo, P; Sharma, P K; van der Tas, H F; van der Houwen, E B; Timmer, M; Magetsari, R; Busscher, H J; van Horn, J R; Verkerke, G J

    2008-07-01

    The enormous need of orthopaedic (surgical) implants such as osteosynthesis plates is difficult to be fulfilled in developing countries commonly rely on imported ones. One of the alternatives is utilization of local resources, but only after they have been proven safe to use, to overcome this problem. Surface properties are some of the determining factors of safety for those implants. We have succeeded in developing prototype of osteosynthesis plate and the results indicate that Indonesian-made plates need improvement with regards to the surface quality of physical characterization.

  17. Linkages Between the Megathrust and Upper-plate Deformation: Lessons From the Deformational Dichotomy of the 2016 Kaikoura New Zealand Earthquake

    NASA Astrophysics Data System (ADS)

    Furlong, K. P.; Herman, M. W.

    2017-12-01

    Following the 2016 Mw 7.8 Kaikoura earthquake, the nature of the coseismic rupture was unclear. Seismological and tsunami evidence pointed to significant involvement of the subduction megathrust, while geodetic and field observations pointed to a shallow set of intra-crustal faults as the main participants during the earthquake. It now appears that the Kaikoura earthquake produced synchronous faulting on the plate boundary subduction interface - the megathrust - and on a suite of crustal faults above the rupture zone in the overlying plate. This Kaikoura-style earthquake, involving synchronous ruptures on multiple components of the plate boundary, may be an important mode of plate boundary deformation affecting seismic hazard along subduction zones. Here we propose a model to explain how these upper-plate faults are loaded during the periods between megathrust earthquakes and subsequently can rupture synchronously with the megathrust. Between megathrust earthquakes, horizontal compression, driven by plate convergence, locks the upper-plate faults, particularly those at higher angles to the convergence direction and the oblique plate motion of the subducting Pacific plate deforms the upper-plate in bulk shear. During the time interval of megathrust rupture, two things happen which directly affect the stress conditions acting on these upper-plate faults: (1) slip on the megathrust and the associated `rebound' of the upper plate reduces the compressive or normal stress acting on the upper plate faults, and (2) the base of the upper plate faults (and the upper plate itself) is decoupled from the slab in the region above rupture area. The reduction in normal stress acting on these faults increases their Coulomb Stress state to strongly favor strike-slip fault slip, and the basal decoupling of the upper plate allows it to undergo nearly complete stress recovery in that region; enabling the occurrence of very large offsets on these faults - offsets that exceed the slip on the plate interface. With these results it is clear that the 2016 Kaikoura NZ earthquake represents a mode of subduction zone rupture that must be considered in other regions.

  18. Toxicity and metabolism of 2,4-dichlorophenol by the aquatic angiosperm Lemna gibba

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ensley, H.E.; Barber, J.T.; Polito, M.A.

    1994-02-01

    The toxicity and metabolism of 2,4-dichlorophenol with regard to the aquatic macrophyte Lemna gibba (duckweed), have been studied. Toxicity is described in terms of the effect of 2,4-dichlorophenol (2,4-DCP) on the vegetative reproduction of duckweed over a 10-d growth period; the EC10 and EC50 were 2.5 and 9.2 [mu]M, respectively. Metabolism of 2,4-dichlorophenol was monitored by incubation of the plants with radiolabeled substrate, and periodic sampling and analysis by reversed-phase HPLC of the plant growth medium. Depending on the growth conditions, up to 95% of the 2,4-DCP was metabolized over a 6-d growth period. To analyze the metabolites, the plantsmore » were grown in the presence of sublethal concentrations of [U-[sup 14]C]-2,4-DCP. The growth medium was lyophilized and then mixed with the plants, extracted, and analyzed using reversed-phase HPLC, followed by scintillation counting of the fractions. The major metabolite was isolated and identified as 2,4-dichlorophenol-[beta]-D-glucopyranoside by high-field NMR and MS. The structure of the metabolite was confirmed by synthesis and by enzymatic cleavage of the [beta]-glucosidic linkage to afford 2,4-DCP. An important consequence of conjugate formation is the masking of the presence of 2,4-DCP to the usual analytical techniques used for its detection and quantitation. This finding is probably applicable to other contaminants and organisms.« less

  19. Synthesis and characterization of Ag₃PO₄ immobilized with graphene oxide (GO) for enhanced photocatalytic activity and stability over 2,4-dichlorophenol under visible light irradiation.

    PubMed

    Chen, Xiao-juan; Dai, You-zhi; Wang, Xing-yan; Guo, Jing; Liu, Tan-hua; Li, Fen-fang

    2015-07-15

    A series of visible-light responsive photocatalysts prepared using Ag3PO4 immobilized with graphene oxide (GO) with varying GO content were obtained by an electrostatically driven method, and 2,4-dichlorophenol (2,4-DCP) was used to evaluate the performance of the photocatalysts. The composites exhibited superior photocatalytic activity and stability compared with pure Ag3PO4. When the content of GO was 5%, the degradation efficiency of 2,4-DCP could reach 98.95%, and 55.91% of the total organic (TOC) content was removed within 60 min irradiation. Meanwhile, the efficiency of 91.77% was achieved for 2,4-DCP degradation even after four times of recycling in the photocatalysis/Ag3PO4-GO (5%) system. Reactive species of O2(˙-), OH˙ and h(+) were considered as the main participants for oxidizing 2,4-DCP, as confirmed by the free radical capture experiments. And some organic intermediates including 4-chlorophenol (4-CP), hydroquinone (HQ), benzoquinone (BZQ), 2-chlorohydroquinone and hydroxyhydroquinone (HHQ) were detected by comparison with the standard retention times from the high performance liquid chromatography (HPLC). In short, the enhanced photocatalytic property of Ag3PO4-GO was closely related to the strong absorption ability of GO relative to 2,4-DCP, the effective separation of photogenerated electron-hole pairs, and the excellent electron capture capability of GO. Copyright © 2015. Published by Elsevier B.V.

  20. Efficient peroxydisulfate activation process not relying on sulfate radical generation for water pollutant degradation.

    PubMed

    Zhang, Tao; Chen, Yin; Wang, Yuru; Le Roux, Julien; Yang, Yang; Croué, Jean-Philippe

    2014-05-20

    Peroxydisulfate (PDS) is an appealing oxidant for contaminated groundwater and toxic industrial wastewaters. Activation of PDS is necessary for application because of its low reactivity. Present activation processes always generate sulfate radicals as actual oxidants which unselectively oxidize organics and halide anions reducing oxidation capacity of PDS and producing toxic halogenated products. Here we report that copper oxide (CuO) can efficiently activate PDS under mild conditions without producing sulfate radicals. The PDS/CuO coupled process is most efficient at neutral pH for decomposing a model compound, 2,4-dichlorophenol (2,4-DCP). In a continuous-flow reaction with an empty-bed contact time of 0.55 min, over 90% of 2,4-DCP (initially 20 μM) and 90% of adsorbable organic chlorine (AOCl) can be removed at the PDS/2,4-DCP molar ratio of 1 and 4, respectively. Based on kinetic study and surface characterization, PDS is proposed to be first activated by CuO through outer-sphere interaction, the rate-limiting step, followed by a rapid reaction with 2,4-DCP present in the solution. In the presence of ubiquitous chloride ions in groundwater/industrial wastewater, the PDS/CuO oxidation shows significant advantages over sulfate radical oxidation by achieving much higher 2,4-DCP degradation capacity and avoiding the formation of highly chlorinated degradation products. This work provides a new way of PDS activation for contaminant removal.

  1. Numerical predictions of shock propagation through unreactive and reactive liquids with experimental validation

    NASA Astrophysics Data System (ADS)

    Stekovic, Svjetlana; Nissen, Erin; Bhowmick, Mithun; Stewart, Donald S.; Dlott, Dana D.

    2017-06-01

    The objective of this work is to numerically analyze shock behavior as it propagates through compressed, unreactive and reactive liquid, such as liquid water and liquid nitromethane. Parameters, such as pressure and density, are analyzed using the Mie-Gruneisen EOS and each multi-material system is modeled using the ALE3D software. The motivation for this study is based on provided high-resolution, optical interferometer (PDV) and optical pyrometer measurements. In the experimental set-up, a liquid is placed between an Al 1100 plate and Pyrex BK-7 glass. A laser-driven Al 1100 flyer impacts the plate, causing the liquid to be highly compressed. The numerical model investigates the influence of the high pressure, shock-compressed behavior in each liquid, the energy transfer, and the wave impedance at the interface of each material in contact. The numerical results using ALE3D will be validated by experimental data. This work aims to provide further understanding of shock-compressed behavior and how the shock influences phase transition in each liquid.

  2. Simultaneous identification and quantification of 4-cumylphenol, 2,4-bis-(dimethylbenzyl)phenol and bisphenol A in prawn Macrobrachium rosenbergii.

    PubMed

    Zuo, Yuegang; Zhu, Zhuo

    2014-07-01

    Bisphenol A (BPA), 4-cumylphenol (4-CP) and 2,4-bis-(dimethylbenzyl)phenol (2,4-DCP) are all high production volume chemicals and widely used in plastic and other consumer products. During the past two decades, BPA has attracted a great deal of scientific and public attention due to its presence in the environment and estrogenic property. Although 4-CP and 2,4-DCP are much more estrogenic and toxic than BPA, little information is available about their occurrence and fate in the environment. In this study, a rapid, selective, accurate and reliable analytical method was developed for the simultaneous determination of 4-CP, 2,4-DCP and BPA in prawn Macrobrachium rosenbergii. The method comprises an ultrasound-accelerated extraction followed by capillary gas chromatographic (GC) separation. The detection limits range from 1.50 to 36.4 ng kg(-1) for the three alkylphenols. The calibration curves are linear over the concentration range tested with the coefficients of determination, R(2), greater than 0.994. The developed method was successfully applied to the simultaneous determination of 4-CP, 2,4-DCP and BPA in prawn samples. The peak identification was confirmed using GC-MS. Bisphenol A, 2,4-bis-(dimethylbenzyl)phenol and 4-cumylphenol were found in prawn samples in the concentration ranges of 0.67-5.51, 0.36-1.61, and 0.00-1.96 ng g(-1) (wet weight), respectively. All relative standard deviations are less than 4.8%. At these environmentally relevant concentration levels, 4-CP, 2,4-DCP and BPA may affect the reproduction and development of aquatic organisms, including negative influence on crustaceans' larval survival, molting, metamorphosis and shell hardening. This is the first study reported on the occurrence of 4-CP, 2,4-DCP and BPA in prawn M. rosenbergii. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Energy efficiency of digestible protein, fat and carbohydrate utilisation for growth in rainbow trout and Nile tilapia.

    PubMed

    Schrama, Johan W; Haidar, Mahmoud N; Geurden, Inge; Heinsbroek, Leon T N; Kaushik, Sachi J

    2018-04-01

    Currently, energy evaluation of fish feeds is performed on a digestible energy basis. In contrast to net energy (NE) evaluation systems, digestible energy evaluation systems do not differentiate between the different types of digested nutrients regarding their potential for growth. The aim was to develop an NE evaluation for fish by estimating the energy efficiency of digestible nutrients (protein, fat and carbohydrates) and to assess whether these efficiencies differed between Nile tilapia and rainbow trout. Two data sets were constructed. The tilapia and rainbow data set contained, respectively, eight and nine experiments in which the digestibility of protein, fat and energy and the complete energy balances for twenty-three and forty-five diets was measured. The digestible protein (dCP), digestible fat (dFat) and digestible carbohydrate intakes (dCarb) were calculated. By multiple regression analysis, retained energy (RE) was related to dCP, dFat and dCarb. In tilapia, all digestible nutrients were linearly related to RE (P<0·001). In trout, RE was quadratically related to dCarb (P<0·01) and linearly to dCP and dFat (P<0·001). The NE formula was NE=11·5×dCP+35·8×dFAT+11·3×dCarb for tilapia and NE=13·5×dCP+33·0×dFAT+34·0×dCarb-3·64×(dCarb)2 for trout (NE in kJ/(kg0·8×d); dCP, dFat and dCarb in g/(kg0·8×d)). In tilapia, the energetic efficiency of dCP, dFat and dCarb was 49, 91 and 66 %, respectively, showing large similarity with pigs. Tilapia and trout had similar energy efficiencies of dCP (49 v. 57 %) and dFat (91 v. 84 %), but differed regarding dCarb.

  4. Compression-extension transition of continental crust in a subduction zone: A parametric numerical modeling study with implications on Mesozoic-Cenozoic tectonic evolution of the Cathaysia Block

    PubMed Central

    Chan, Lung Sang; Gao, Jian-Feng

    2017-01-01

    The Cathaysia Block is located in southeastern part of South China, which situates in the west Pacific subduction zone. It is thought to have undergone a compression-extension transition of the continental crust during Mesozoic-Cenozoic during the subduction of Pacific Plate beneath Eurasia-Pacific Plate, resulting in extensive magmatism, extensional basins and reactivation of fault systems. Although some mechanisms such as the trench roll-back have been generally proposed for the compression-extension transition, the timing and progress of the transition under a convergence setting remain ambiguous due to lack of suitable geological records and overprinting by later tectonic events. In this study, a numerical thermo-dynamical program was employed to evaluate how variable slab angles, thermal gradients of the lithospheres and convergence velocities would give rise to the change of crustal stress in a convergent subduction zone. Model results show that higher slab dip angle, lower convergence velocity and higher lithospheric thermal gradient facilitate the subduction process. The modeling results reveal the continental crust stress is dominated by horizontal compression during the early stage of the subduction, which could revert to a horizontal extension in the back-arc region, combing with the roll-back of the subducting slab and development of mantle upwelling. The parameters facilitating the subduction process also favor the compression-extension transition in the upper plate of the subduction zone. Such results corroborate the geology of the Cathaysia Block: the initiation of the extensional regime in the Cathaysia Block occurring was probably triggered by roll-back of the slowly subducting slab. PMID:28182640

  5. 5'-Phosphorothiolate Dinucleotide Cap Analogues: Reagents for Messenger RNA Modification and Potent Small-Molecular Inhibitors of Decapping Enzymes.

    PubMed

    Wojtczak, Blazej A; Sikorski, Pawel J; Fac-Dabrowska, Kaja; Nowicka, Anna; Warminski, Marcin; Kubacka, Dorota; Nowak, Elzbieta; Nowotny, Marcin; Kowalska, Joanna; Jemielity, Jacek

    2018-05-09

    The 5' cap consists of 7-methylguanosine (m 7 G) linked by a 5'-5'-triphosphate bridge to messenger RNA (mRNA) and acts as the master regulator of mRNA turnover and translation initiation in eukaryotes. Cap analogues that influence mRNA translation and turnover (either as small molecules or as part of an RNA transcript) are valuable tools for studying gene expression, which is often also of therapeutic relevance. Here, we synthesized a series of 15 dinucleotide cap (m 7 GpppG) analogues containing a 5'-phosphorothiolate (5'-PSL) moiety (i.e., an O-to-S substitution within the 5'-phosphoester) and studied their biological properties in the context of three major cap-binding proteins: translation initiation factor 4E (eIF4E) and two decapping enzymes, DcpS and Dcp2. While the 5'-PSL moiety was neutral or slightly stabilizing for cap interactions with eIF4E, it significantly influenced susceptibility to decapping. Replacing the γ-phosphoester with the 5'-PSL moiety (γ-PSL) prevented β-γ-pyrophosphate bond cleavage by DcpS and conferred strong inhibitory properties. Combining the γ-PSL moiety with α-PSL and β-phosphorothioate (PS) moiety afforded first cap-derived hDcpS inhibitor with low nanomolar potency. Susceptibility to Dcp2 and translational properties were studied after incorporation of the new analogues into mRNA transcripts by RNA polymerase. Transcripts containing the γ-PSL moiety were resistant to cleavage by Dcp2. Surprisingly, superior translational properties were observed for mRNAs containing the α-PSL moiety, which were Dcp2-susceptible. The overall protein expression measured in HeLa cells for this mRNA was comparable to mRNA capped with the translation augmenting β-PS analogue reported previously. Overall, our study highlights 5'-PSL as a synthetically accessible cap modification, which, depending on the substitution site, can either reduce susceptibility to decapping or confer superior translational properties on the mRNA. The 5'-PSL-analogues may find application as reagents for the preparation of efficiently expressed mRNA or for investigation of the role of decapping enzymes in mRNA processing or neuromuscular disorders associated with decapping.

  6. Incorporation of {sup 210}Pb and {sup 210}Po to Poultry through the Addition of Dicalcium Phosphate (DCP) to the Diet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Casacuberta, N.; Masque, P.; Garcia-Orellana, J.

    Due to the replacement of calcium by uranium in the phosphorite, sedimentary phosphate rock contains high concentrations of {sup 238}U (i.e. from 1500 Bq{center_dot}kg{sup -1} in Morocco to 4000 Bq{center_dot}kg{sup -1} in Tanzania ores). Dicalcium Phosphate (DCP) is produced by the wet acid digestion of the phosphorite, and is used as a source of calcium and phosphorus for livestock feed supplement. If the phosphorite acid digestion is made with hydrochloric acid, DCP may present specific activities of about 10{sup 3} Bq{center_dot}kg{sup -1} of {sup 238}U and some of its decay chain daughters. In particular, due to its radiological implications, themore » presence of {sup 210}Pb and {sup 210}Po in DCP is of special relevance. The aim of this work was to investigate the potential incorporation of these radionuclides to poultry through its diet. Three different diets were therefore prepared with different contents of both DCP and {sup 210}Pb and {sup 210}Po. Diet A was used as a blank, and had a 2.5% in weight of monocalcium phosphate (MCP); diet B, with a 5% in weight of DCP; and diet C, with a 2.5% of DCP. Concentrations of {sup 210}Pb were 0.93, 101.4 and 51.2 Bq{center_dot}kg{sup -1}; whereas concentrations of {sup 210}Po were 0.92, 74 and 36 Bq{center_dot}kg{sup -1} of food for diets A, B and C, respectively. Accumulation of {sup 210}Pb and {sup 210}Po was analysed at several times during poultry growth in samples of bone, liver, kidney, muscle, excrements as well as entire animals, with a total of 30 broilers fed with the 3 different diets. Results showed clear enhancements in the accumulation of both {sup 210}Pb and {sup 210}Po in chicken for diets B and C, and in particular in liver and bone. However, total accumulation of radionuclides in chicken, and especially in edible parts, is low compared to its expulsion through excrements. These results are interpreted in terms of the potential dose through consumption of chicken.« less

  7. Shock wave absorber having apertured plate

    DOEpatents

    Shin, Y.W.; Wiedermann, A.H.; Ockert, C.E.

    1983-08-26

    The shock or energy absorber disclosed herein utilizes an apertured plate maintained under the normal level of liquid flowing in a piping system and disposed between the normal liquid flow path and a cavity pressurized with a compressible gas. The degree of openness (or porosity) of the plate is between 0.01 and 0.60. The energy level of a shock wave travelling down the piping system thus is dissipated by some of the liquid being jetted through the apertured plate toward the cavity. The cavity is large compared to the quantity of liquid jetted through the apertured plate, so there is little change in its volume. The porosity of the apertured plate influences the percentage of energy absorbed.

  8. Shock wave absorber having apertured plate

    DOEpatents

    Shin, Yong W.; Wiedermann, Arne H.; Ockert, Carl E.

    1985-01-01

    The shock or energy absorber disclosed herein utilizes an apertured plate maintained under the normal level of liquid flowing in a piping system and disposed between the normal liquid flow path and a cavity pressurized with a compressible gas. The degree of openness (or porosity) of the plate is between 0.01 and 0.60. The energy level of a shock wave travelling down the piping system thus is dissipated by some of the liquid being jetted through the apertured plate toward the cavity. The cavity is large compared to the quantity of liquid jetted through the apertured plate, so there is little change in its volume. The porosity of the apertured plate influences the percentage of energy absorbed.

  9. Estimation of leaf area index and foliage clumping in deciduous forests using digital photography

    NASA Astrophysics Data System (ADS)

    Chianucci, Francesco; Cutini, Andrea

    2013-04-01

    Rapid, reliable and meaningful estimates of leaf area index (LAI) are essential to the characterization of forest ecosystems. In this contribution the accuracy of both fisheye and non-fisheye digital photography for the estimation of forest leaf area in deciduous stands was evaluated. We compared digital hemispherical photography (DHP), the most widely used technique that measures the gap fraction at multiple zenith angles, with methods that measure the gap fraction at a single zenith angle, namely 57.5 degree photography and cover photography (DCP). Comparison with other different gap fraction methods used to calculate LAI such as canopy transmittance measurements from AccuPAR ceptometer and LAI- 2000 Plant Canopy Analyzer (PCA) were also performed. LAI estimated from all these indirect methods were compared with direct measurements obtained by litter traps (LAILT). We applied these methods in 10 deciduous stands of Quercus cerris, Castanea sativa and Fagus sylvatica, the most common deciduous species in Italy, where LAILT ranged from 3.9 to 7.3. DHP and DCP provided good indirect estimates of LAILT, and outperformed the other indirect methods. The DCP method provided estimates of crown porosity, crown cover, foliage cover and the clumping index at the zenith, but required assumptions about the light extinction coefficient at the zenith (k), to accurately estimate LAI. Cover photography provided good indirect estimates of LAI assuming a spherical leaf angle distribution, even though k appeared to decrease as LAI increased, thus affecting the accuracy of LAI estimates in DCP. In contrast, the accuracy of LAI estimates in DHP appeared insensitive to LAILT values, but the method was sensitive to photographic exposure, gamma-correction and was more time-consuming than DCP. Foliage clumping was estimated from all the photographic methods by analyzing either gap size distribution (DCP) or gap fraction distribution (DHP). Foliage clumping was also calculated from PCA and compared with DHP. The studied stands were characterized by fairly homogeneous canopies with higher within-crown clumping than between-crowns clumping; only the segmented analysis of gap fraction for each ring of the fisheye images was found to provide useful clumping index in such homogeneous canopies. By contrast, the 1-azimuth segment method employed in PCA poorly detected clumping in dense canopies. We conclude both fisheye and non-fisheye photographic methods are suitable for dense deciduous forests. Cover photography holds great promise as a means to quickly obtain inexpensive estimates of LAI over large areas. However, in situations where no direct reference measurements of k are available, we recommend using both DHP and DCP, in order to cross-calibrate the two methods; DCP could then be used for more routinely indirect measurement and monitoring of LAI. Keywords: digital hemispherical photography, cover photography, litter trap, AccuPAR ceptometer, LAI-2000.

  10. A comparison of simultaneous plasma, atomic absorption, and iron colorimetric determinations of major and trace constituents in acid mine waters

    USGS Publications Warehouse

    Ball, J.W.; Nordstrom, D. Kirk

    1994-01-01

    Sixty-three water samples collected during June to October 1982 from the Leviathan/Bryant Creek drainage basin were originally analyzed by simultaneous multielement direct-current plasma (DCP) atomic-emission spectrometry, flame atomic-absorption spectrometry, graphite-furnace atomic-absorption spectrometry (GFAAS) (thallium only), ultraviolet-visible spectrometry, and hydride-generation atomic-absorption spectrometry.Determinations were made for the following metallic and semi-metallic constituents: AI, As, B, Ba, Be, Bi, Cd, Ca, Cr, Co, Cu, Fe(11), Fe(total), Li, Pb, Mg, Mn, Mo, Ni, K, Sb, Se, Si, Na, Sr, TI, V, and Zn. These samples were re-analyzed later by simultaneous multielement inductively coupled plasma (ICP) atomic-emission spectrometry and Zeeman-corrected GFAAS to determine the concentrations of many of the same constituents with improved accuracy, precision, and sensitivity. The result of this analysis has been the generation of comparative concentration values for a significant subset of the solute constituents. Many of the more recently determined values replace less-than-detection values for the trace metals; others constitute duplicate analyses for the major constituents. The multiple determinations have yielded a more complete, accurate, and precise set of analytical data. They also have resulted in an opportunity to compare the performance of the plasma-emission instruments operated in their respective simultaneous multielement modes. Flame atomic-absorption spectrometry was judged best for Na and K and hydride-generation atomic-absorption spectrometry was judged best for As because of their lower detection limit and relative freedom from interelement spectral effects. Colorimetric determination using ferrozine as the color agent was judged most accurate, precise, and sensitive for Fe. Cadmium, lead, and vanadium concentrations were too low in this set of samples to enable a determination of whether ICP or DCP is a more suitable technique. Of the remaining elements, Ba, Be, Ca, Cr, Mg, Mn, Sr, and Zn have roughly equivalent accuracy, precision, and detection limit by ICP and DCP. Cobalt and Ni were determined to be better analyzed by ICP, because of lower detection limits; B, Cu, Mo, and Si were determined to be better analyzed by DCP, because of relative freedom from interferences. The determination oral by DCP was far more sensitive, owing to the use of a more sensitive wavelength, compared with the ICP. However, there is a very serious potential interference from a strong Ca emission line near the 396.15 nanometer DCP wavelength. Thus, there is no clear choice between the plasma techniques tested, for the determination oral. The ICP and DCP detection limits are typically between 0.001 and 0.5 milligrams per liter in acid mine waters. For those metals best analyzed by ICP and/or DCP, but below these limits, GFAAS is the method of choice because of its relatively greater sensitivity and specificity. Six of the elements were not determined by DCP, ICP or Zeeman-corrected GFAAS, and are not discussed in this report. These elements are: Bi, Fe(11), Li, Sb, Se, and TI.

  11. Deformable silicone grating fabricated with a photo-imprinted polymer mold

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamada, Itsunari, E-mail: yamada.i@e.usp.ac.jp; Nishii, Junji; Saito, Mitsunori

    A tunable transmission grating was fabricated by molding a silicone elastomer (polydimethylsiloxane). Its optical characteristics were then evaluated during compression. For fabrication, a glass plate with a photoimprinted polymer grating film was used as a mold. Both the grating period and diffraction transmittance of the molded elastomer were functions of the compressive stress. The grating period changed from 3.02 to 2.86 μm during compressing the elastomer in the direction perpendicular to the grooves.

  12. Design of graphene nanoparticle undergoing axial compression: quantum study

    NASA Astrophysics Data System (ADS)

    Glukhova, O. E.; Kirillova, I. V.; Saliy, I. N.; Kolesnikova, A. S.; Slepchenkov, M. M.

    2011-03-01

    We report the results of quantum mechanical investigations of the atomic structure and deformations of graphene nanoparticle undergoing axial compression. We applied the tight-binding (TB) method. Our transferable tightbinding potential correctly reproduced tight-binding changes in the electronic configuration as a function of the local bonding geometry around each carbon atom. The tight-binding method applied provided the consideration and calculation of the rehybridization between σ- and π-orbitals. To research nanoribbons using tight-binding potential our own program was used. We adapted TB method to be able to run the algorithm on a parallel computing machine (computer cluster). To simulate axial compression of graphene nanoparticles the atoms on the ends were fixed on the plates. The plates were moved towards each other to decrease the length at some percent. Plane atomic network undergoing axial compression became wave-like. The amplitude of wave and its period were not constant and changed along axis. This is a phase transition. The strain energy collapse occurs at the value of axial compression 0.03-0.04. The strain energy increased up to the quantity compression 0.03, then collapsed sharply and decreased. So according to our theoretical investigation, the elasticity of graphene nanoparticles is more than the elasticity of nanotubes the same width and length. The curvature of the atomic network because of compression will decrease the reactivity of graphene nanoparticles. We have calculated the atomic structure and electronic structure of the compression graphene nanopaticle at each step of strain of axial compression. We have come to the conclusion that the wave-like graphenes adsorbing protein and nucleic acid are the effective nanosensors and bionanosensors.

  13. On the effects of assembly compression on the performance of liquid-feed DMFCs under methanol-limiting conditions: A 2D numerical study

    NASA Astrophysics Data System (ADS)

    García-Salaberri, P. A.; Vera, M.

    2015-07-01

    The influence of assembly compression on the performance of liquid-feed DMFCs under methanol-limiting conditions is explored by means of a 2D/1D multiphysics across-the-channel model. The numerical formulation incorporates a comprehensive 2D description of the anode GDL, including two-phase phenomena, non-uniform anisotropic transport properties, and electrical contact resistances at the GDL/BPP interface. GDL effective properties are evaluated using empirical data corresponding to Toray® carbon paper. A simplified but physically sound 1D description, locally coupled to the 2D anode GDL model, is adopted to describe transport processes in the MPLs, membrane and cathode GDL, whereas the catalyst layers are treated as infinitely thin surfaces. Good agreement is found between the numerical results and previous experimental data. The interplay between assembly compression, bipolar plate material, and channel configuration is also investigated. The results show that there is an optimum GDL compression ratio in terms of overall power density, the optimal compression level being strongly dependent on bipolar plate material. Beyond the optimum, the detrimental effect of compression is larger in non-parallel flow fields due to the additional reduction of methanol transported by under-rib convection. The results suggest that, under certain conditions, this transport mechanism could be more important than diffusion in the anode of liquid-feed DMFCs.

  14. Inflatable O-ring seal would ease closing of hatch cover plate

    NASA Technical Reports Server (NTRS)

    Neary, K. J.

    1966-01-01

    Inflatable O-ring seal provides positive sealing means that does not require the manual exertion of a large compressive force during opening or closing of a rotary-type hatch cover plate. The O-ring is deflated during opening and closing and inflated after closure by a gas pressure source.

  15. Development and verification of global/local analysis techniques for laminated composites

    NASA Technical Reports Server (NTRS)

    Thompson, Danniella Muheim; Griffin, O. Hayden, Jr.

    1991-01-01

    A two-dimensional to three-dimensional global/local finite element approach was developed, verified, and applied to a laminated composite plate of finite width and length containing a central circular hole. The resulting stress fields for axial compression loads were examined for several symmetric stacking sequences and hole sizes. Verification was based on comparison of the displacements and the stress fields with those accepted trends from previous free edge investigations and a complete three-dimensional finite element solution of the plate. The laminates in the compression study included symmetric cross-ply, angle-ply and quasi-isotropic stacking sequences. The entire plate was selected as the global model and analyzed with two-dimensional finite elements. Displacements along a region identified as the global/local interface were applied in a kinematically consistent fashion to independent three-dimensional local models. Local areas of interest in the plate included a portion of the straight free edge near the hole, and the immediate area around the hole. Interlaminar stress results obtained from the global/local analyses compares well with previously reported trends, and some new conclusions about interlaminar stress fields in plates with different laminate orientations and hole sizes are presented for compressive loading. The effectiveness of the global/local procedure in reducing the computational effort required to solve these problems is clearly demonstrated through examination of the computer time required to formulate and solve the linear, static system of equations which result for the global and local analyses to those required for a complete three-dimensional formulation for a cross-ply laminate. Specific processors used during the analyses are described in general terms. The application of this global/local technique is not limited software system, and was developed and described in as general a manner as possible.

  16. Using H. Stephen Glenn's Developing Capable People Program with Adults in Montana: How Effective Is the Curriculum?

    ERIC Educational Resources Information Center

    Astroth, Kirk A.; Lorbeer, Scott

    1998-01-01

    Pre/posttest scores of 30 participants in H. Stephen Glenn's Developing Capable People (DCP) program offered by Montana Extension showed that DCP effectively increased the use of positive behaviors and decreased negative behaviors in adults interacting with youth. These changes were sustained over 18 months after program completion. (SK)

  17. Grafting of Bacterial Polyhydroxybutyrate (PHB) onto Cellulose via In Situ Reactive Extrusion with Dicumyl Peroxide

    Treesearch

    Liqing Wei; Armando G. McDonald; Nicole M. Stark

    2015-01-01

    Polyhydroxybutyrate (PHB) was grafted onto cellulose fiber by dicumyl peroxide (DCP) radical initiation via in situ reactive extrusion. The yield of the grafted (cellulose-g-PHB) copolymer was recorded and grafting efficiency was found to be dependent on the reaction time and DCP concentration. The grafting mechanism was investigated by electron spin...

  18. ORAL TOXICITY OF 1,3-DICHLOROPROPANE: ACUTE, SHORT-TERM, AND LONG-TERM STUDIES IN RATS

    EPA Science Inventory

    The objective of this investigation was to characterize the acute and short- and long-term toxic potency of orally administered 1,2-dichloropropane (DCP). In the acute and short-term studies, male rats of 250-300 g were gavaged with 0, 100, 250, 500, or 1000 mg DCP/kg in corn oil...

  19. Arthroscopic-assisted Locking Compression Plate clavicular hook fixation for unstable fractures of the lateral end of the clavicle: a prospective study

    PubMed Central

    Lee, Kwang Won; Kim, Kap Jung; Kim, Yong In; Kwon, Won Cho; Choy, Won Sik

    2009-01-01

    The aim of this prospective study was to assess the clinical outcomes of an unstable fracture of the lateral end of the clavicle treated with an arthroscopic-assisted locking compressive plate (LCP) clavicular hook plate. Twenty-three patients underwent arthroscopic assisted LCP clavicular hook plate fixation for these fractures. All patients achieved clinical and radiological union over a mean of 4.2 months (range, 3.4–5 months). Four patients (17%) showed some degree of acromial osteolysis. Three patients (13%) showed radiological signs of arthrosis of the acromioclavicular joint. In one patient, a second fracture (stress) was observed between the medial two screws of the plate without an additional injury. Five patients (22%) showed subacromial bursitis on dynamic ultrasonography. The mean Constant and Murley score was 91 points (range, 81–98). The average level of pain in the shoulder at rest and on abduction was 1 (range, 0–2) and 2.4 (range, 0–4), respectively. Based on our experience, arthroscopic-assisted LCP hook plate fixation for the treatment of unstable fractures of the lateral end of the clavicle is not without complications. However, it is an acceptable alternative method that is easy to apply with good results. Furthermore, it prevents rotator cuff impingement, allows early mobilisation and maintains the acromioclavicular joint biomechanics. PMID:19998033

  20. [Case-control study on minimally invasive percutaneous locking compression plate internal fixation for the treatment of type II and III pilon fractures].

    PubMed

    Zhang, Zhi-Da; Ye, Xiu-Yi; Shang, Li-Yong; Xu, Rong-Ming; Zhu, Yan-Zhao

    2011-12-01

    To explore the clinical efficacy of delayed open reduction and internal fixation with minimally invasive percutaneous locking compression plate for the treatment of type II and III Pilon fractures. From January 2007 to September 2009, 32 patients with type II and III Pilon fractures were treated with open reduction and anatomic plate fixation (AP group) and minimally invasive percutaneous locking compression plate osteosynthesis (LCP group). There were 11 males and 6 females in AP group, with an average age of (37.4 +/- 13.3) years (ranged, 19 to 55 years). And there were 10 males and 5 females in LCP group, with an average age of (34.6 +/- 11.3) years(ranged, 21 to 56 years). The operating time, fracture healing time, aligned angulation and ankle function were compared between the two groups. All the patients were followed up, and the during ranged from 12 to 25 months, with a mean of (15.0 +/- 1.7) months. The average operation time was (76.5 +/- 8.3) min for AP group and (58.3 +/- 3.4) min for LCP group; the average time of fracture healing was (20.5 +/- 0.4) weeks for AP group and (15.7 +/- 0.2) weeks for LCP group; the total angulation between anterior posterior film and lateral film was averaged (6.6 +/- 0.5) degrees for AP group and (3.6 +/- 0.2) degrees for LCP group. As to above index, the results of LCP group were better than those of AP group (P < 0.05). According to Kofoed criteria for ankle joint, the results of LCP group were better than those of AP group in ankle joint pain, wakling and ankle joint function (P < 0.05). The method of minimally invasive percutaneous locking compression plate internal fixation is effective in the treatment of Pilon fracture with less invasion, faster bone union, more stabilized fixation, quicker recovery of ankle function and fewer complications, which is more advantaged for type II and III Pilon fractures.

  1. Global Tectonics of Enceladus: Numerical Model

    NASA Astrophysics Data System (ADS)

    Czechowski, Leszek

    2016-10-01

    Introduction: Enceladus, a satellite of Saturn, is the smallest celestial body in the Solar System where volcanic and tectonic activities are observed. Every second, the mass of 200 kg is ejected into space from the South Polar Terrain (SPT) - [1]. The loss of matter from the body's interior should lead to global compression of the crust. Typical effects of compression are: thrust faults, folding and subduction. However, such forms are not dominant on Enceladus. We propose here special tectonic process that could explain this paradox. Our hypotheses states that the mass loss from SPT is the main driving mechanism of the following tectonic processes: subsidence of SPT, flow in the mantle and motion of adjacent tectonic plates. The hypotheses is presented in [2], [3] and[4].We suggest that the loss of the volatiles results in a void, an instability, and motion of solid matter to fill the void. The motion is presented at the Fig.1 and includes:Subsidence of the 'lithosphere' of SPT.Flow of the matter in the mantle.Motion of plates adjacent to SPT towards the active regionMethods and results: The numerical model of processes presented is developed. It is based on the equations of continuous media..If emerging void is being filled by the subsidence of SPT only, then the velocity of subsidence is 0.05 mmyr-1. However, numerical calculations indicate that all three types of motion are usually important. The role of a given motion depends on the viscosity distribution. Generally, for most of the models the subsidence is 0.02 mmyr-1, but mantle flow and plates' motion also play a role in filling the void. The preliminary results of the numerical model indicate also that the velocity of adjacent plates could be 0.02 mmyr-1 for the Newtonian rheology.Note that in our model the reduction of the crust area is not a result of compression but it is a result of the plate sinking. Therefore the compressional surface features do not have to be dominant. The SPT does not have to be compressed, so the open "tiger stripes" could exist for long time. e suppose that it means the end of activity in the given region.

  2. Structural efficiencies of various aluminum, titanium, and steel alloys at elevated temperatures

    NASA Technical Reports Server (NTRS)

    Heimerl, George J; Hughes, Philip J

    1953-01-01

    Efficient temperature ranges are indicated for two high-strength aluminum alloys, two titanium alloys, and three steels for some short-time compression-loading applications at elevated temperatures. Only the effects of constant temperatures and short exposure to temperature are considered, and creep is assumed not to be a factor. The structural efficiency analysis is based upon preliminary results of short-time elevated-temperature compressive stress-strain tests of the materials. The analysis covers strength under uniaxial compression, elastic stiffness, column buckling, and the buckling of long plates in compression or in shear.

  3. Biomechanical Assessment of the Dorsal Spanning Bridge Plate in Distal Radius Fracture Fixation: Implications for Immediate Weight-Bearing.

    PubMed

    Huang, Jerry I; Peterson, Bret; Bellevue, Kate; Lee, Nicolas; Smith, Sean; Herfat, Safa

    2017-04-01

    The goal of this study was to compare the biomechanical stability of a 2.4-mm dorsal spanning bridge plate with a volar locking plate (VLP) in a distal radius fracture model, during simulated crutch weight-bearing. Five paired cadaveric forearms were tested. A 1-cm dorsal wedge osteotomy was created to simulate an unstable distal radius fracture with dorsal comminution. Fractures were fixed with a VLP or a dorsal bridge plate (DBP). Specimens were mounted to a crutch handle, and optical motion-tracking sensors were attached to the proximal and distal segments. Specimens were loaded in compression at 1 mm/s on a servohydraulic test frame until failure, defined as 2 mm of gap site displacement. The VLP construct was significantly more stable to axial load in a crutch weight-bearing model compared with the DBP plate (VLP: 493 N vs DBP: 332 N). Stiffness was higher in the VLP constructs, but this was not statistically significant (VLP: 51.4 N/mm vs DBP: 32.4 N/mm). With the crutch weight-bearing model, DBP failed consistently with wrist flexion and plate bending, whereas VLP failed with axial compression at the fracture site and dorsal collapse. Dorsal spanning bridge plating is effective as an internal spanning fixator in treating highly comminuted intra-articular distal radius fracture and prevents axial collapse at the radiocarpal joint. However, bridge plating may not offer advantages in early weight-bearing or transfer in polytrauma patients, with less axial stability in our crutch weight-bearing model compared with volar plating. A stiffer 3.5-mm DBP or use of a DBP construct without the central holes may be considered for distal radius fractures if the goal is early crutch weight-bearing through the injured extremity.

  4. Web buckling behavior under in-plane compression and shear loads for web reinforced composite sandwich core

    NASA Astrophysics Data System (ADS)

    Toubia, Elias Anis

    Sandwich construction is one of the most functional forms of composite structures developed by the composite industry. Due to the increasing demand of web-reinforced core for composite sandwich construction, a research study is needed to investigate the web plate instability under shear, compression, and combined loading. If the web, which is an integral part of the three dimensional web core sandwich structure, happens to be slender with respect to one or two of its spatial dimensions, then buckling phenomena become an issue in that it must be quantified as part of a comprehensive strength model for a fiber reinforced core. In order to understand the thresholds of thickness, web weight, foam type, and whether buckling will occur before material yielding, a thorough investigation needs to be conducted, and buckling design equations need to be developed. Often in conducting a parametric study, a special purpose analysis is preferred over a general purpose analysis code, such as a finite element code, due to the cost and effort usually involved in generating a large number of results. A suitable methodology based on an energy method is presented to solve the stability of symmetrical and specially orthotropic laminated plates on an elastic foundation. Design buckling equations were developed for the web modeled as a laminated plate resting on elastic foundations. The proposed equations allow for parametric studies without limitation regarding foam stiffness, geometric dimensions, or mechanical properties. General behavioral trends of orthotropic and symmetrical anisotropic plates show pronounced contribution of the elastic foundation and fiber orientations on the buckling resistance of the plate. The effects of flexural anisotropy on the buckling behavior of long rectangular plates when subjected to pure shear loading are well represented in the model. The reliability of the buckling equations as a design tool is confirmed by comparison with experimental results. Comparing to predicted values, the experimental plate shear test results range between 15 and 35 percent, depending on the boundary conditions considered. The compression testing yielded conservative results, and as such, can provide a valuable tool for the designer.

  5. Similar Modes of Interaction Enable Trailer Hitch and EDC3 To Associate with DCP1 and Me31B in Distinct Protein Complexes▿ †

    PubMed Central

    Tritschler, Felix; Eulalio, Ana; Helms, Sigrun; Schmidt, Steffen; Coles, Murray; Weichenrieder, Oliver; Izaurralde, Elisa; Truffault, Vincent

    2008-01-01

    Trailer Hitch (Tral or LSm15) and enhancer of decapping-3 (EDC3 or LSm16) are conserved eukaryotic members of the (L)Sm (Sm and Like-Sm) protein family. They have a similar domain organization, characterized by an N-terminal LSm domain and a central FDF motif; however, in Tral, the FDF motif is flanked by regions rich in charged residues, whereas in EDC3 the FDF motif is followed by a YjeF_N domain. We show that in Drosophila cells, Tral and EDC3 specifically interact with the decapping activator DCP1 and the DEAD-box helicase Me31B. Nevertheless, only Tral associates with the translational repressor CUP, whereas EDC3 associates with the decapping enzyme DCP2. Like EDC3, Tral interacts with DCP1 and localizes to mRNA processing bodies (P bodies) via the LSm domain. This domain remains monomeric in solution and adopts a divergent Sm fold that lacks the characteristic N-terminal α-helix, as determined by nuclear magnetic resonance analyses. Mutational analysis revealed that the structural integrity of the LSm domain is required for Tral both to interact with DCP1 and CUP and to localize to P-bodies. Furthermore, both Tral and EDC3 interact with the C-terminal RecA-like domain of Me31B through their FDF motifs. Together with previous studies, our results show that Tral and EDC3 are structurally related and use a similar mode to associate with common partners in distinct protein complexes. PMID:18765641

  6. Similar modes of interaction enable Trailer Hitch and EDC3 to associate with DCP1 and Me31B in distinct protein complexes.

    PubMed

    Tritschler, Felix; Eulalio, Ana; Helms, Sigrun; Schmidt, Steffen; Coles, Murray; Weichenrieder, Oliver; Izaurralde, Elisa; Truffault, Vincent

    2008-11-01

    Trailer Hitch (Tral or LSm15) and enhancer of decapping-3 (EDC3 or LSm16) are conserved eukaryotic members of the (L)Sm (Sm and Like-Sm) protein family. They have a similar domain organization, characterized by an N-terminal LSm domain and a central FDF motif; however, in Tral, the FDF motif is flanked by regions rich in charged residues, whereas in EDC3 the FDF motif is followed by a YjeF_N domain. We show that in Drosophila cells, Tral and EDC3 specifically interact with the decapping activator DCP1 and the DEAD-box helicase Me31B. Nevertheless, only Tral associates with the translational repressor CUP, whereas EDC3 associates with the decapping enzyme DCP2. Like EDC3, Tral interacts with DCP1 and localizes to mRNA processing bodies (P bodies) via the LSm domain. This domain remains monomeric in solution and adopts a divergent Sm fold that lacks the characteristic N-terminal alpha-helix, as determined by nuclear magnetic resonance analyses. Mutational analysis revealed that the structural integrity of the LSm domain is required for Tral both to interact with DCP1 and CUP and to localize to P-bodies. Furthermore, both Tral and EDC3 interact with the C-terminal RecA-like domain of Me31B through their FDF motifs. Together with previous studies, our results show that Tral and EDC3 are structurally related and use a similar mode to associate with common partners in distinct protein complexes.

  7. Structures and Nuclear Quadrupole Coupling Tensors of a Series of Chlorine-Containing Hydrocarbons

    NASA Astrophysics Data System (ADS)

    Dikkumbura, Asela S.; Webster, Erica R.; Dorris, Rachel E.; Peebles, Rebecca A.; Peebles, Sean A.; Seifert, Nathan A.; Pate, Brooks

    2016-06-01

    Rotational spectra for gauche-1,2-dichloroethane (12DCE), gauche-1-chloro-2-fluoroethane (1C2FE) and both anti- and gauche-2,3-dichloropropene (23DCP) have been observed using chirped-pulse Fourier-transform microwave (FTMW) spectroscopy in the 6-18 GHz region. Although the anti conformers for all three species are predicted to be more stable than the gauche forms, they are nonpolar (12DCE) or nearly nonpolar (predicted dipole components for anti-1C2FE: μ_a = 0.11 D, μ_b = 0.02 D and for anti-23DCP: μ_a = 0.25 D, μ_b = 0.02 D); nevertheless, it was also possible to observe and assign the spectrum of anti-23DCP. Assignments of parent spectra and 37Cl and 13C substituted isotopologues utilized predictions at the MP2/6-311++G(2d,2p) level and Pickett's SPCAT/SPFIT programs. For the weak anti-23DCP spectra, additional measurements also utilized a resonant-cavity FTMW spectrometer. Full chlorine nuclear quadrupole coupling tensors for gauche-12DCE and both anti- and gauche-23DCP have been diagonalized to allow comparison of coupling constants. Kraitchman's equations were used to determine r_s coordinates of isotopically substituted atoms and r_0 structures were also deduced for gauche conformers of 12DCE and 1C2FE. Structural details and chlorine nuclear quadrupole coupling constants of all three molecules will be compared, and effects of differing halogen substitution and carbon chain length on molecular properties will be evaluated.

  8. Guide to DCP Study Close-Out: Milestones and Tasks | Division of Cancer Prevention

    Cancer.gov

    This guide assists Consortium Lead Organization (CLO) planning for DCP study close-out. Study close-out tasks are organized under milestones, which help mark progress toward completion of the close-out process. Once tasks associated with a milestone are underway, planning for the next milestone may begin. Click on a milestone to view the associated close-out tasks. |

  9. External Link Policy | Division of Cancer Prevention

    Cancer.gov

    The following graphic notice means that you are leaving the DCP Web site: (link is external)This external link provides additional information that is consistent with the intended purpose of DCP.The National Cancer Institute (NCI) cannot attest to the accuracy of a non-federal site.Linking to a non-federal site does not constitute an endorsement by HHS or any of its employees

  10. 76 FR 70717 - DCP Midstream, LP; Notice of Intent To Prepare an Environmental Assessment for the Proposed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-15

    ... (FERC or Commission) will prepare an environmental assessment (EA) that will discuss the environmental... Midstream, LP (DCP) in Weld County, Colorado. This EA will be used by the Commission in its decision-making... be evaluated in the EA. Please note that the scoping period will close on December 8, 2011. Comments...

  11. Opening wedge and anatomic-specific plates in foot and ankle applications.

    PubMed

    Kluesner, Andrew J; Morris, Jason B

    2011-08-01

    As surgeons continually push to improve techniques and outcomes, anatomic-specific and procedure-specific fixation options are becoming increasingly available. The unique size, shape, and function of the foot provide an ideal framework for the use of anatomic-specific plates. These distinctive plate characteristics range from anatomic contouring and screw placements to incorporated step-offs and wedges. By optimizing support, compression, and stabilization, patients may return to weight bearing and activity sooner, improving outcomes. This article discusses anatomic-specific plates and their use in forefoot and rearfoot surgical procedures. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Effects of process variables and kinetics on the degradation of 2,4-dichlorophenol using advanced reduction processes (ARP).

    PubMed

    Yu, Xingyue; Cabooter, Deirdre; Dewil, Raf

    2018-05-24

    This study aims at investigating the efficiency and kinetics of 2,4-DCP degradation via advanced reduction processes (ARP). Using UV light as activation method, the highest degradation efficiency of 2,4-DCP was obtained when using sulphite as a reducing agent. The highest degradation efficiency was observed under alkaline conditions (pH = 10.0), for high sulphite dosage and UV intensity, and low 2,4-DCP concentration. For all process conditions, first-order reaction rate kinetics were applicable. A quadratic polynomial equation fitted by a Box-Behnken Design was used as a statistical model and proved to be precise and reliable in describing the significance of the different process variables. The analysis of variance demonstrated that the experimental results were in good agreement with the predicted model (R 2  = 0.9343), and solution pH, sulphite dose and UV intensity were found to be key process variables in the sulphite/UV ARP. Consequently, the present study provides a promising approach for the efficient degradation of 2,4-DCP with fast degradation kinetics. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Sensitivity studies of pediatric material properties on juvenile lumbar spine responses using finite element analysis.

    PubMed

    Jebaseelan, D Davidson; Jebaraj, C; Yoganandan, Narayan; Rajasekaran, S; Kanna, Rishi M

    2012-05-01

    The objective of the study was to determine the sensitivity of material properties of the juvenile spine to its external and internal responses using a finite element model under compression, and flexion-extension bending moments. The methodology included exercising the 8-year-old juvenile lumbar spine using parametric procedures. The model included the vertebral centrum, growth plates, laminae, pedicles, transverse processes and spinous processes; disc annulus and nucleus; and various ligaments. The sensitivity analysis was conducted by varying the modulus of elasticity for various components. The first simulation was done using mean material properties. Additional simulations were done for each component corresponding to low and high material property variations. External displacement/rotation and internal stress-strain responses were determined under compression and flexion-extension bending. Results indicated that, under compression, disc properties were more sensitive than bone properties, implying an elevated role of the disc under this mode. Under flexion-extension moments, ligament properties were more dominant than the other components, suggesting that various ligaments of the juvenile spine play a key role in modulating bending behaviors. Changes in the growth plate stress associated with ligament properties explained the importance of the growth plate in the pediatric spine with potential implications in progressive deformities.

  14. Shockwave compression of Ar gas at several initial densities

    NASA Astrophysics Data System (ADS)

    Dattelbaum, Dana M.; Goodwin, Peter M.; Garcia, Daniel B.; Gustavsen, Richard L.; Lang, John M.; Aslam, Tariq D.; Sheffield, Stephen A.; Gibson, Lloyd L.; Morris, John S.

    2017-01-01

    Experimental data of the principal Hugoniot locus of variable density gas-phase noble and molecular gases are rare. The majority of shock Hugoniot data is either from shock tube experiments on low-pressure gases or from plate impact experiments on cryogenic, liquefied gases. In both cases, physics regarding shock compressibility, thresholds for the on-set of shock-driven ionization, and even dissociation chemistry are difficult to infer for gases at intermediate densities. We have developed an experimental target design for gas gun-driven plate impact experiments on noble gases at initial pressures between 200-1000 psi. Using optical velocimetry, we are able to directly determine both the shock and particle velocities of the gas on the principal Hugoniot locus, as well as clearly differentiate ionization thresholds. The target design also results in multiply shocking the gas in a quasi-isentropic fashion yielding off-Hugoniot compression data. We describe the results of a series of plate impact experiments on Ar with starting densities between 0.02-0.05 g/cm3 at room temperature. Furthermore, by coupling optical fibers to the targets, we have measured the time-resolved optical emission from the shocked gas using a spectrometer coupled to an optical streak camera to spectrally-resolve the emission, and with a 5-color optical pyrometer for temperature determination.

  15. Buckling behavior of compression-loaded symmetrically-laminated angle-ply plates with holes

    NASA Technical Reports Server (NTRS)

    Nemeth, M. P.

    1986-01-01

    An approximate analysis for buckling of a rectangular specially-orthotropic plate with a central circular hole is applied to symmetrically-laminated angle-ply plates. Results obtained from finite element analyses and experiments indicate that the approximate analysis predicts accurately the buckling loads of (+/-theta sub m)s plates with integer values of m not below 6 and with hole diameters up to 50 percent of the plate width. Moreover, the results indicate that the approximate analysis can be used to predict the buckling trends of plates with hole diameters up to 70 percent of the plate width. Results of a parametric study indicate the influence of hole size, plate aspect ratio, loading conditions, boundary conditions, and orthotropy on the buckling load. Results are also presented that indicate the relationship of the bending stiffness and the prebuckling load distribution to the buckling load of a plate with a hole.

  16. Characterization of Borosilicate Glass Through Confined Compression Testing with Numerical Validation

    DTIC Science & Technology

    2009-11-01

    Characterization Data and Flyer-Plate Impact Data 7.1 Introduction Borosilicate and soda - lime glass have been the object of extensive plate impact...2 GPa as the strength of damaged soda - lime glass at pressures of 4 to 6 GPa. Bourne, et al. [9, 35], showed tests with strength values of 1.8 GPa...equation of state data for borosilicate and soda - lime glass . The flyer-plate impact data greatly extends the confining pressures that can be achieved with

  17. Fuel cell collector plate and method of fabrication

    DOEpatents

    Braun, James C.; Zabriskie, Jr., John E.; Neutzler, Jay K.; Fuchs, Michel; Gustafson, Robert C.

    2001-01-01

    An improved molding composition is provided for compression molding or injection molding a current collector plate for a polymer electrolyte membrane fuel cell. The molding composition is comprised of a polymer resin combined with a low surface area, highly-conductive carbon and/or graphite powder filler. The low viscosity of the thermoplastic resin combined with the reduced filler particle surface area provide a moldable composition which can be fabricated into a current collector plate having improved current collecting capacity vis-a-vis comparable fluoropolymer molding compositions.

  18. ERTS-1 DCS technical support provided by Wallops Station. [ground truth stations and DCP repair depot

    NASA Technical Reports Server (NTRS)

    Smith, R.

    1975-01-01

    Wallops Station accepted the tasks of providing ground truth to several ERTS investigators, operating a DCP repair depot, designing and building an airborne DCP Data Acquisition System, and providing aircraft underflight support for several other investigators. Additionally, the data bank is generally available for use by ERTS and other investigators that have a scientific interest in data pertaining to the Chesapeake Bay area. Working with DCS has provided a means of evaluating the system as a data collection device possibly applicable to ongoing Earth Resources Program activities in the Chesapeake Bay area as well as providing useful data and services to other ERTS investigators. The two areas of technical support provided by Wallops, ground truth stations and repair for DCPs, are briefly discussed.

  19. Biomechanical Comparison of Superior Versus Anterior Plate Position for Fixation of Distal Clavicular Fractures: A New Model.

    PubMed

    Wilkerson, James; Paryavi, Ebrahim; Kim, Hyunchul; Murthi, Anand; Pensy, Raymond A

    2017-01-01

    Although most clavicular fractures are amenable to nonoperative management, metadiaphyseal fractures are considerably more complex, with rates of suboptimal healing as high as 75% when treated nonoperatively. The poor results are ascribed to the deforming forces on the distal clavicle from the surrounding muscles and the weight of the arm. It recently has been noted that some operative fixations of these fractures are also failing when a standard superiorly placed plate is used. We hypothesized that anterior plating, when compared with superior plating, improves the strength and durability of the construct by redirecting the axis of the major deforming force across rather than in line with the screws of the construct. Six pairs of fresh-frozen human cadaveric clavicles with the scapula attached by the coracoclavicular ligaments were osteotomized just medial to the ligaments and plated with a standard 3.5-mm limited-contact dynamic compression plate. Specimens were potted and mounted on a materials testing system machine, preserving the anatomic relationship of the clavicle and scapula. They were then loaded through the coracoclavicular ligaments to mimic the weight of the arm pulling inferiorly. Each specimen was loaded with 375 N at 1 Hz for 2000 cycles. Sequential loading was then applied at 25-N intervals until failure. Statistical analysis was performed using a Wilcoxon signed-rank test. The superiorly plated specimens failed after fewer cycles and with lower force than the anteriorly plated specimens. The median number of cycles to failure was 2082 for anterior plated specimens and 50 for superiorly plated (P = 0.028). The median load to failure was 587.5 N in the anterior group and 375 N in the superior group (P = 0.035). The median stiffness was 46.13 N/mm for anterior and 40.45 N/mm for superior (P = 0.375) plates. Anteriorly plated distal third clavicular fractures have superior strength and durability compared with fractures plated superiorly when using a physician-contoured, 3.5-mm, limited-contact, dynamic compression plate in this cadaver model.

  20. Determining the geotechnical properties of planetary regolith using Low Velocity Penetrometers

    NASA Astrophysics Data System (ADS)

    Seweryn, K.; Skocki, K.; Banaszkiewicz, M.; Grygorczuk, J.; Kolano, M.; Kuciński, T.; Mazurek, J.; Morawski, M.; Białek, A.; Rickman, H.; Wawrzaszek, R.

    2014-09-01

    Measurements of mechanical and thermophysical properties of planetary surface allow determining many important parameters useful for planetologists. For example, effective heat conductivity or thermal inertia of the regolith can help to better understand the processes occurring in the bodies interior. Chemical and mineralogical composition gives us a chance to determine the origin and evolution of moons and satellites. Mechanical properties of the surface are one of the key factors needed by civil engineers for developing future bases on space bodies. Space missions to planetary bodies highly restrict the payload concerning its mass and power consumption. Therefore, it is quite impossible to use a standard terrestrial technique like the Load Plate Test or Direct Shear Tests to determine the geotechnical parameters of the planetary regolith. Even the Dynamic Cone Penetration (DCP) method, which is frequently used for field testing, does not fit well with the constraints imposed by a space mission. Nevertheless, its operation principle is very similar to that of at the Low Velocity Penetrators (LVP), several of them being currently on their way to planetary bodies (e.g. the MUPUS instrument) or which were developed in the last couple of years (e.g. the CHOMIK instrument or the KRET device). In this paper we present a comparison between DCP method and LVP operation which was observed during several tests campaigns during mole KRET and CHOMIK instrument development. The tests were performed in different planetary analogues: JSC-1A, Chenobi and AGK-2010, Phobos analogue, cometary analogues F1, F2 and F3 (SRC) and dry quartz sand. In the last part of the paper the concept of results' interpretation is presented.

  1. Classification and treatment of periprosthetic supracondylar femur fractures.

    PubMed

    Ricci, William

    2013-02-01

    Locked plating and retrograde nailing are two accepted methods for treatment of periprosthetic distal femur fractures. Each has relative benefits and potential pitfalls. Appropriate patient selection and knowledge of the specific femoral component geometry are required to optimally choose between these two methods. Locked plating may be applied to most periprosthetic distal femur fractures. The fracture pattern, simple or comminuted, will dictate the specific plating technique, compression plating or bridge plating. Nailing requires an open intercondylar box and a distal fragment of enough size to allow interlocking. With proper patient selection and proper techniques, good results can be obtained with either method. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. Passive margins getting squeezed in the mantle convection vice

    NASA Astrophysics Data System (ADS)

    Yamato, Philippe; Husson, Laurent; Becker, Thorsten W.; Pedoja, Kevin

    2013-12-01

    margins often exhibit uplift, exhumation, and tectonic inversion. We speculate that the compression in the lithosphere gradually increased during the Cenozoic, as seen in the number of mountain belts found at active margins during that period. Less clear is how that compression increase affects passive margins. In order to address this issue, we design a 2-D viscous numerical model wherein a lithospheric plate rests above a weaker mantle. It is driven by a mantle conveyor belt, alternatively excited by a lateral downwelling on one side, an upwelling on the other side, or both simultaneously. The lateral edges of the plate are either free or fixed, representing the cases of free convergence, and collision (or slab anchoring), respectively. This distinction changes the upper mechanical boundary condition for mantle circulation and thus, the stress field. Between these two regimes, the flow pattern transiently evolves from a free-slip convection mode toward a no-slip boundary condition above the upper mantle. In the second case, the lithosphere is highly stressed horizontally and deforms. For a constant total driving force, compression increases drastically at passive margins if upwellings are active. Conversely, if downwellings alone are activated, compression occurs at short distances from the trench and extension prevails elsewhere. These results are supported by Earth-like models that reveal the same pattern, where active upwellings are required to excite passive margins compression. Our results substantiate the idea that compression at passive margins is in response to the underlying mantle flow that is increasingly resisted by the Cenozoic collisions.

  3. Geometry of slab, intraslab stress field and its tectonic implication in the Nankai trough, Japan

    NASA Astrophysics Data System (ADS)

    Xu, J.; Kono, Y.

    2002-07-01

    The characteristics of geometry of slabs and the intraslab stress field in the Nankai subduction zone, Japan, were analyzed based on highly accurate hypocentral data and focal mechanism solutions. The results suggest that the shallow seismic zone of the Philippine Sea slab subducts with dip angels between 10 and 22 degrees beneath Shikoku and the Kii peninsula, and between 11 and 40 degrees beneath Kyushu. Two types of seismogenic stress field exist within the slab. The stress field of down-dip compression type can be seen in the slab beneath Shikoku and the Kii peninsula, where the horizontal component of regional compression stress is NNW. On the other hand the stress field of down-dip extension type within the slab is dominant in the region from western Shikoku to Kyushu, where the direction of horizontal compressive stress is near WWN. The existence of the two types of stress field is related to the differences of slab geometry and slab age of the subduciton zone. These properties imply that slab beneath Kyushu (40 Ma) probably is older than that beneath Shikoku and the Kii peninsula (11-20 Ma). The young slab of the oceanic Philippine Sea plate subducts with a shallow angle beneath the Eurasian plate in Shikoku and the Kii peninsula. The subduction has encountered strong resistance there, resulting in a down-dip compression stress field. The down-dip extension stress field may be related to the older slab of the Philippine Sea plate which subducts beneath Kyushu with a steeper dip angle.

  4. Compression member response of double steel angles on truss structure with member length variation

    NASA Astrophysics Data System (ADS)

    Hasibuan, Purwandy; Panjaitan, Arief; Haiqal, Muhammad

    2018-05-01

    One type of structures that implements steel angles as its members is truss system of telecommunication tower. For this structure, reinforcements on tower legs are also needed when antennas and microwaves installation placed on the peak of tower increases in quantity. One type of reinforcement methods commonly used is by increasing areas section capacity, where tower leg consisted of single angle section will be reinforced to be double angle sections. Regarding this case, this research discussed behavior two types of double angle steel section 2L 30.30.3 that were designed identically in area section but vary in length: 103 cm and 83 cm. At the first step, compression member together with tension member was formed to be a truss system, where compression and tension member were met at the joint plate. Schematic loading was implemented by giving tension loading on the joint plate, and this loading was terminated when each specimen reached its failure. Research findings showed that implementing shorter double angle (83 cm) sections, increased compression strength of steel angle section up to 13 %. Significant deformation occurring only on the flange for both of specimens indicated that implementing double angle is effective to prevent lateral-torsional buckling.

  5. Minimally invasive repair of pectus carinatum and how to deal with complications

    PubMed Central

    Aragone, Xavier; Blanco, Javier Borbore; Ciano, Alejandro; Abramson, Leonardo

    2016-01-01

    While less common than pectus excavatum, pectus carinatum is also a chest wall deformity affecting males in higher proportion than women. Patient requests for a solution of this disease occur especially during the growth spurt of puberty when this malformation becomes more obvious and difficult to conceal. Those people suffering from pectus carinatum are very likely subject to behavioral changes and negative personality impacts. By compressing the protruding anterior region of the chest wall we achieve correction of the chest contour and simultaneous lateral expansion of the depressed costochondral arches. This original technique and the procedure to apply it fit within the category of minimally invasive surgery. The compression system acts in a way similar to that of orthodontic braces. Two rectangular fixation plates are fixed to the compression strut with screws. The plates have threaded holes along a groove in the central portion, and two holes at both ends used to attach them to the ribs by means of steel wire suture. The compression strut has to be modified into a convex shape to adapt it to the particular characteristics of the patient’s malformation. This molding is done using benders designed as part of the procedure. PMID:29078492

  6. Minimally invasive repair of pectus carinatum and how to deal with complications.

    PubMed

    Abramson, Horacio; Aragone, Xavier; Blanco, Javier Borbore; Ciano, Alejandro; Abramson, Leonardo

    2016-01-01

    While less common than pectus excavatum, pectus carinatum is also a chest wall deformity affecting males in higher proportion than women. Patient requests for a solution of this disease occur especially during the growth spurt of puberty when this malformation becomes more obvious and difficult to conceal. Those people suffering from pectus carinatum are very likely subject to behavioral changes and negative personality impacts. By compressing the protruding anterior region of the chest wall we achieve correction of the chest contour and simultaneous lateral expansion of the depressed costochondral arches. This original technique and the procedure to apply it fit within the category of minimally invasive surgery. The compression system acts in a way similar to that of orthodontic braces. Two rectangular fixation plates are fixed to the compression strut with screws. The plates have threaded holes along a groove in the central portion, and two holes at both ends used to attach them to the ribs by means of steel wire suture. The compression strut has to be modified into a convex shape to adapt it to the particular characteristics of the patient's malformation. This molding is done using benders designed as part of the procedure.

  7. Measure of displacement around holes in composite plates subjected to quasi-static compression

    NASA Technical Reports Server (NTRS)

    Duke, J. C., Jr.; Post, D.; Czarnek, R.; Asundi, A.

    1986-01-01

    Contour maps of thickness changes were obtained for three quasi-isotropic graphite-epoxy plates with central holes, loaded in compression. Thickness changes were determined for six load increments from nearly zero to within a few percent of the failure load. The largest change of thickness occurred near the hole but not at the boundary of the hole. Below 90 percent of the failure load, the thickness changes were nearly proportional to load. Irregularities of thickness changes occurred in zones of compressive stresses and they were attributed to localized fiber buckling. A new optical technique was developed to measure thickness changes with high sensitivity. It utilizes a comparatively simple means of holographic interferometry on both sides of the specimen, followed by additive moire to obtain thickness changes as the sum of the out-of-plane displacements. Sensitivity was 12.5 x 10 to the -6 power in. per fringe order. The fringe patterns represent thickness changes uniquely, even when specimen warpage and consequent out-of-plane displacements are very large.

  8. Normalized stiffness ratios for mechanical characterization of isotropic acoustic foams.

    PubMed

    Sahraoui, Sohbi; Brouard, Bruno; Benyahia, Lazhar; Parmentier, Damien; Geslain, Alan

    2013-12-01

    This paper presents a method for the mechanical characterization of isotropic foams at low frequency. The objective of this study is to determine the Young's modulus, the Poisson's ratio, and the loss factor of commercially available foam plates. The method is applied on porous samples having square and circular sections. The main idea of this work is to perform quasi-static compression tests of a single foam sample followed by two juxtaposed samples having the same dimensions. The load and displacement measurements lead to a direct extraction of the elastic constants by means of normalized stiffness and normalized stiffness ratio which depend on Poisson's ratio and shape factor. The normalized stiffness is calculated by the finite element method for different Poisson ratios. The no-slip boundary conditions imposed by the loading rigid plates create interfaces with a complex strain distribution. Beforehand, compression tests were performed by means of a standard tensile machine in order to determine the appropriate pre-compression rate for quasi-static tests.

  9. Thermal conductivity of a graphite bipolar plate (BPP) and its thermal contact resistance with fuel cell gas diffusion layers: Effect of compression, PTFE, micro porous layer (MPL), BPP out-of-flatness and cyclic load

    NASA Astrophysics Data System (ADS)

    Sadeghifar, Hamidreza; Djilali, Ned; Bahrami, Majid

    2015-01-01

    This paper reports on measurements of thermal conductivity of a graphite bipolar plate (BPP) as a function of temperature and its thermal contact resistance (TCR) with treated and untreated gas diffusion layers (GDLs). The thermal conductivity of the BPP decreases with temperature and its thermal contact resistance with GDLs, which has been overlooked in the literature, is found to be dominant over a relatively wide range of compression. The effects of PTFE loading, micro porous layer (MPL), compression, and BPP out-of-flatness are also investigated experimentally. It is found that high PTFE loadings, MPL and even small BPP out-of-flatness increase the BPP-GDL thermal contact resistance dramatically. The paper also presents the effect of cyclic load on the total resistance of a GDL-BPP assembly, which sheds light on the behavior of these materials under operating conditions in polymer electrolyte membrane fuel cells.

  10. A flex-compressive-mode piezoelectric transducer for mechanical vibration/strain energy harvesting.

    PubMed

    Li, Xiaotian; Guo, Mingsen; Dong, Shuxiang

    2011-04-01

    A piezoelectric transducer for harvesting energy from ambient mechanical vibrations/strains under pressure condition was developed. The proposed transducer was made of two ring-type piezoelectric stacks, one pair of bow-shaped elastic plates, and one shaft that pre-compresses them. This transducer works in flex-compressive (F-C) mode, which is different from a conventional flex-tensional (F-T) one, to transfer a transversely applied force F into an amplified longitudinal force N pressing against the two piezo-stacks via the two bowshaped elastic plates, generating a large electric voltage output via piezoelectric effect. Our experimental results show that without an electric load, an F-C mode piezo-transducer could generate a maximum electric voltage output of up to 110 Vpp, and with an electric load of 40 κΩ, it a maximum power output of 14.6 mW under an acceleration excitation of 1 g peak-peak at the resonance frequency of 87 Hz. © 2011 IEEE

  11. Discovering the Complexity of Capable Faults in Northern Chile

    NASA Astrophysics Data System (ADS)

    Gonzalez, G.; del Río, I. A.; Rojas Orrego, C., Sr.; Astudillo, L. A., Sr.

    2017-12-01

    Great crustal earthquakes (Mw >7.0) in the upper plate of subduction zones are relatively uncommon and less well documented. We hypothesize that crustal earthquakes are poorly represented in the instrumental record because they have long recurrence intervals. In northern Chile, the extreme long-term aridity permits extraordinary preservation of landforms related to fault activity, making this region a primary target to understand how upper plate faults work at subduction zones. To understand how these faults relate to crustal seismicity in the long-term, we have conducted a detailed palaeoseismological study. We performed a palaeoseismological survey integrating trench logging and photogrammetry based on UAVs. Optically stimulated luminescence (OSL) age determinations were practiced for dating deposits linked to faulting. In this contribution we present the study case of two primary faults located in the Coastal Cordillera of northern Chile between Iquique (21ºS) and Antofagasta (24ºS). We estimate the maximum moment magnitude of earthquakes generated in these upper plate faults, their recurrence interval and the fault-slip rate. We conclude that the studied upper plate faults show a complex kinematics on geological timescales. Faults seem to change their kinematics from normal (extension) to reverse (compression) or from normal to transcurrent (compression) according to the stage of subduction earthquake cycle. Normal displacement is related to coseismic stages and compression is linked to interseismic period. As result this complex interaction these faults are capable of generating Mw 7.0 earthquakes, with recurrence times on the order of thousands of years during every stage of the subduction earthquake cycle.

  12. Evaluation of Two Miniplate Systems and Figure-of-eight Bandages for Stabilization of Experimentally Induced Ulnar and Radial Fractures in Pigeons ( Columba livia ).

    PubMed

    Bennert, Beatrice M; Kircher, Patrick R; Gutbrod, Andreas; Riechert, Juliane; Hatt, Jean-Michel

    2016-06-01

    Although plate fixation has advantages over other fixation methods for certain indications, it is rarely used in avian surgery, especially in birds that weigh less than 1000 g. Exceptionally small plating systems for these birds are required, which are relatively expensive and difficult to insert. To study avian fracture healing after repair using miniplates, we evaluated 2 steel miniplate systems in 27 pigeons ( Columba livia ) divided into 4 groups. In each pigeon, the left ulna and radius were transected and the ulna was repaired with a bone plate. In groups A and B, a 1.3-mm adaption plate was applied without and with a figure-of-eight bandage; in groups C and D, a 1.0-mm compression plate was applied without and with a bandage, respectively. Healing was evaluated with radiographs after 3, 14, and 28 days; flight tests were conducted after 14, 21, and 28 days; and the wing was macroscopically examined after euthanasia of birds on day 28. Fractures healed without bending or distortion of the plate in all 27 birds, and no significant differences in healing were found between treatment groups. At the end of the study, 23 pigeons (85.2%) showed good or very good flight ability. Results show the 1.3-mm adaption plate and the 1.0-mm compression plate meet the requirements for avian osteosynthesis and can be recommended for fracture repair of the ulna or other long bones in birds weighing less than 500 g. The application of a figure-of-eight bandage might be beneficial in fracture healing.

  13. A pulse-shaping technique to investigate the behaviour of brittle materials subjected to plate-impact tests.

    PubMed

    Forquin, Pascal; Zinszner, Jean-Luc

    2017-01-28

    Owing to their significant hardness and compressive strengths, ceramic materials are widely employed for use with protective systems subjected to high-velocity impact loadings. Therefore, their mechanical behaviour along with damage mechanisms need to be significantly investigated as a function of loading rates. However, the classical plate-impact testing procedures produce shock loadings in the brittle sample material which cause unrealistic levels of loading rates. Additionally, high-pulsed power techniques and/or functionally graded materials used as flyer plates to smooth the loading pulse remain costly, and are generally difficult to implement. In this study, a shockless plate-impact technique based on the use of either a wavy-machined flyer plate or buffer plate that can be produced by chip-forming is proposed. A series of numerical simulations using an explicit transient dynamic finite-element code have been performed to design and validate the experimental testing configuration. The calculations, conducted in two-dimensional (2D) plane-strain or in 2D axisymmetric modes, prove that the 'wavy' contact surface will produce a pulse-shaping effect, whereas the buffer plate will produce a homogenizing effect of the stress field along the transverse direction of the sample. In addition, 'wavy-shape' geometries of different sizes provide an easy way to change the level of loading rate and rise time in an experimentally tested ceramic specimen. Finally, when a shockless compression loading method is applied to the sample, a Lagrangian analysis of data is made possible by considering an assemblage of ceramic plates of different thicknesses in the target, so the axial stress-strain response of the brittle sample material can be provided.This article is part of the themed issue 'Experimental testing and modelling of brittle materials at high strain rates'. © 2016 The Author(s).

  14. A pulse-shaping technique to investigate the behaviour of brittle materials subjected to plate-impact tests

    NASA Astrophysics Data System (ADS)

    Forquin, Pascal; Zinszner, Jean-Luc

    2017-01-01

    Owing to their significant hardness and compressive strengths, ceramic materials are widely employed for use with protective systems subjected to high-velocity impact loadings. Therefore, their mechanical behaviour along with damage mechanisms need to be significantly investigated as a function of loading rates. However, the classical plate-impact testing procedures produce shock loadings in the brittle sample material which cause unrealistic levels of loading rates. Additionally, high-pulsed power techniques and/or functionally graded materials used as flyer plates to smooth the loading pulse remain costly, and are generally difficult to implement. In this study, a shockless plate-impact technique based on the use of either a wavy-machined flyer plate or buffer plate that can be produced by chip-forming is proposed. A series of numerical simulations using an explicit transient dynamic finite-element code have been performed to design and validate the experimental testing configuration. The calculations, conducted in two-dimensional (2D) plane-strain or in 2D axisymmetric modes, prove that the `wavy' contact surface will produce a pulse-shaping effect, whereas the buffer plate will produce a homogenizing effect of the stress field along the transverse direction of the sample. In addition, `wavy-shape' geometries of different sizes provide an easy way to change the level of loading rate and rise time in an experimentally tested ceramic specimen. Finally, when a shockless compression loading method is applied to the sample, a Lagrangian analysis of data is made possible by considering an assemblage of ceramic plates of different thicknesses in the target, so the axial stress-strain response of the brittle sample material can be provided. This article is part of the themed issue 'Experimental testing and modelling of brittle materials at high strain rates'.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Everett, J.R.; Russell, O.R.; Staskowski, R.J.

    Analysis of 38 contiguous Landsat Multispectral Scanner scenes acquired over Myanmar (Burma) reveals numerous large-scale features associated with margins of the Burman plate, previously unidentified northeast-southwest-trending discontinuities, important extensions of previously mapped fault trends, and numerous structural features that appear favorable for petroleum exploration. A mosaic of these scenes at 1:1,000,000 scale shows a large number of tectonic elements and their spatial relationships. Within the area of investigation are portions of the Indian, Burman, Lhasa, and Shan-Thai plates, and perhaps other, smaller plates. The Himalayan front and Indo-Burman Ranges manifest effects of current and recently past plate movement. The complexitymore » of the kinematic history accounts for the diversity of structural features in the area. The last major event in this long and violent saga, which began in middle Miocene (approximately 11 Ma) time and continues to the present, is the recent change from a collisional to a right-lateral strike-slip transform margin between the Indian and Burman plates. The complexity of the structures visible is the product of multiple plate collisions, rotation of the Indian plate and parts of the Asian plate, and long-continued convergence that changed velocity and direction tbrough time. The most obvious evidence of this complexity, which is immediately apparent on geologic maps or the Landsat mosaic of the region, is the almost right-angle relationship of the folds of the Indo-Burman Ranges and the frontal thrusts and suture zones of the Himalaya. These two sets of compressive features imply maximum compressive stress axes that lie at right angles to each other. The implications are either that the orientation of the stress field changes rapidly over a short distance or that the stress field has changed through time. Both occurrences seem to be true.« less

  16. Basin formation and Neogene sedimentation in a backarc setting, Halmahera, eastern Indonesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, R.; Nichols, G.J.

    1991-03-01

    It has been proposed that basins in backarc setting form in association with subduction by thinning of continental crust, backarc spreading in oceanic crust, compression, or trapping of pieces of oceanic plate behind an arc. The Halmahera basin in eastern Indonesia developed in a backarc setting but does not fall into these categories; it formed by subsidence of thickened crust made up of imbricated Mesozoic-Paleogene arc and ophiolite rocks. Halmahera lies at the western edge of the Philippine Sea Plate in a complex zone of convergence between the Eurasian margin, the oceanic plates of the West Pacific, and the Australian/Indianmore » Plate to the south. The basement is an imbricated complex of Mesozoic to Paleogene ophiolite, arc, and arc-related rocks. During the Miocene this basement complex formed an area of thickened crust upon which carbonate reef and reef-associated sediments were deposited. The authors interpret this shallow marine region to be similar to many of the oceanic plateaus and ridges found within the Philippine Sea Plate today. In the Late Miocene, convergence between the Philippine Sea Plate and the Eurasian margin resulted in the formation of the Halmahera Trench to the west of this region of thickened crust. Subduction of the Molucca Sea Plate caused the development of a volcanic island arc. Subsidence in the backarc area produced a broad sedimentary basin filled by clastics eroded from the arc and from uplifted basement and cover rocks. The basin was asymmetric with the thickest sedimentary fill on the western side, against the volcanic arc. The Halmahera basin was modified in the Plio-Pleistocene by east-west compression as the Molucca Sea Plate was eliminated by subduction.« less

  17. IN VITRO DETERMINATION OF KINETIC CONSTANTS FOR 1,3-DICHLOROPROPANE, 2,2-DICHLOROPROPANE, AND 1,1-DICHLOROPROPENE IN RAT LIVER MICROSOMES AND CYTOSOL

    EPA Science Inventory

    The Safe Drinking Water Act requires the U.S. EPA to establish a list of contaminants to aid in priority setting for the Agency's drinking water program. The 1998 Contaminant Candidate List (CCL) designated 1,3-Dichloropropane (1,3-DCP), 2,2-dichloropropane (2,2-DCP), and 1,1-...

  18. District-Charter Partnerships: Collaboration to Advance Teaching and Learning in New York City. Year 1 Evaluation Results (2016-17)

    ERIC Educational Resources Information Center

    Litt, J.; Fishel, G.

    2017-01-01

    The Office of School Design and Charter Partnerships (OSDCP) at the New York City Department of Education (DOE) developed and executed a plan for district-charter collaboration, which they called the District-Charter Partnerships (DCP) initiative. This document describes the results of a mixed-method study of DCP conducted during the 2016-17…

  19. A simultaneous derivatization of 3-monochloropropanediol and 1,3-dichloropropane with hexamethyldisilazane-trimethylsilyl trifluoromethanesulfonate at room temperature for efficient analysis of food sample analysis.

    PubMed

    Lee, Bai Qin; Wan Mohamed Radzi, Che Wan Jasimah Bt; Khor, Sook Mei

    2016-02-05

    This paper reports the application of hexamethyldisilazane-trimethylsilyl trifluoromethanesulfonate (HMDS-TMSOTf) for the simultaneous silylation of 3-monochloro-1,2-propanediol (3-MCPD) and 1,3-dicholoropropanol (1,3-DCP) in solid and liquid food samples. 3-MCPD and 1,3-DCP are chloropropanols that have been established as Group 2B carcinogens in clinical testing. They can be found in heat-processed food, especially when an extended high-temperature treatment is required. However, the current AOAC detection method is time-consuming and expensive. Thus, HMDS-TMSOTf was used in this study to provide a safer, and cost-effective alternative to the HFBI method. Three important steps are involved in the quantification of 3-MCPD and 1,3-DCP: extraction, derivatization and quantification. The optimization of the derivatization process, which involved focusing on the catalyst volume, derivatization temperature, and derivatization time was performed based on the findings obtained from both the Box-Behnken modeling and a real experimental set up. With the optimized conditions, the newly developed method was used for actual food sample quantification and the results were compared with those obtained via the standard AOAC method. The developed method required less samples and reagents but it could be used to achieve lower limits of quantification (0.0043mgL(-1) for 1,3-DCP and 0.0011mgL(-1) for 3-MCPD) and detection (0.0028mgL(-1) for 1,3-DCP and 0.0008mgL(-1) for 3-MCPD). All the detected concentrations are below the maximum tolerable limit of 0.02mgL(-1). The percentage of recovery obtained from food sample analysis was between 83% and 96%. The new procedure was validated with the AOAC method and showed a comparable performance. The HMDS-TMSOTf derivatization strategy is capable of simultaneously derivatizing 1,3-DCP and 3-MCPD at room temperature, and it also serves as a rapid, sensitive, and accurate analytical method for food samples analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Distributed Relaxation Multigrid and Defect Correction Applied to the Compressible Navier-Stokes Equations

    NASA Technical Reports Server (NTRS)

    Thomas, J. L.; Diskin, B.; Brandt, A.

    1999-01-01

    The distributed-relaxation multigrid and defect- correction methods are applied to the two- dimensional compressible Navier-Stokes equations. The formulation is intended for high Reynolds number applications and several applications are made at a laminar Reynolds number of 10,000. A staggered- grid arrangement of variables is used; the coupled pressure and internal energy equations are solved together with multigrid, requiring a block 2x2 matrix solution. Textbook multigrid efficiencies are attained for incompressible and slightly compressible simulations of the boundary layer on a flat plate. Textbook efficiencies are obtained for compressible simulations up to Mach numbers of 0.7 for a viscous wake simulation.

  1. Tectonic stress in the plates

    NASA Technical Reports Server (NTRS)

    Richardson, R. M.; Solomon, S. C.; Sleep, N. H.

    1979-01-01

    In the present paper, the basic set of global intraplate stress orientation data is plotted and tabulated. Although the global intraplate stress field is complicated, several large-scale patterns can be seen. Much of stable North America is characterized by an E-W to NE-SW trend for the maximum compressive stress. South American lithosphere beneath the Andes, and perhaps farther east in the stable interior, has horizontal compressive stresses trending E-W to NW-SE. Western Europe north of the Alps is characterized by a NW-SE trending maximum horizontal compression, while Asia has the maximum horizontal compressive stress trending more nearly N-S, especially near the Himalayan front.

  2. Primary cilia modulate Ihh signal transduction in response to hydrostatic loading of growth plate chondrocytes.

    PubMed

    Shao, Yvonne Y; Wang, Lai; Welter, Jean F; Ballock, R Tracy

    2012-01-01

    Indian hedgehog (Ihh) is a key component of the regulatory apparatus governing chondrocyte proliferation and differentiation in the growth plate. Recent studies have demonstrated that the primary cilium is the site of Ihh signaling within the cell, and that primary cilia are essential for bone and cartilage formation. Primary cilia are also postulated to act as mechanosensory organelles that transduce mechanical forces acting on the cell into biological signals. In this study, we used a hydrostatic compression system to examine Ihh signal transduction under the influence of mechanical load. Our results demonstrate that hydrostatic compression increased both Ihh gene expression and Ihh-responsive Gli-luciferase activity. These increases were aborted by disrupting the primary cilia structure with chloral hydrate. These results suggest that growth plate chondrocytes respond to hydrostatic loading by increasing Ihh signaling, and that the primary cilium is required for this mechano-biological signal transduction to occur. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Peculiarity of the Relationship between the Seismicity and Tectonic Structure of the Pyrenees

    NASA Astrophysics Data System (ADS)

    Lukk, A. A.; Shevchenko, V. I.

    2018-05-01

    The geotectonic position of the Pyrenees mountain massif in the Alpine-Indonesian mobile belt is considered. The geological data testify to the formation of the structure of the Pyrenees in the setting of a subhorizontal compression perpendicular to the ridge. The commonly accepted interpretation considers this compression in the context of plate tectonic notions related to the collision between the Iberian and Eurasian lithospheric plates resulting from the convergence of the Eurasian and African plates. However, this interpretation is challenged by the the geodetic and seismological measurements. The GPS measurements suggest a certain cross-strike spreading rather than shortening of the Earth's crust; the focal mechanisms of the earthquakes indicate the predominance of a subhorizontal extension perpendicular to the strike of the Pyrenees mountain range. The processes of the gravitational collapse of the mountain chain during the isostatic upwelling of the orogenic crust are considered as the most probable cause of this spreading by a number of the authors.

  4. Effect of Curvature on the Impact Damage Characteristics and Residual Strength of Composite Plates

    NASA Technical Reports Server (NTRS)

    Ambur, Damodar R.; Starnes, James H., Jr.

    1998-01-01

    The results of a study of the response and failure characteristics of thin, cylindrically curved, composite plates subjected to low-speed impact damage are presented. The results indicate that the plate radius and the plate thickness are important structural parameters that influence the nonlinear response of a plate for a given amount of impact energy. Analytical and experimental contact-force results are compared for several plates and the results correlate well. The impact-energy levels required to cause damage initiation and barely visible impact damage are a function of the plate radius for a given plate thickness. The impact-energy levels required to initiate impact damage for plates with a certain range of radii are greater than plates with other radii. The contact-force results corresponding to these impact-energy levels follow a similar trend. Residual strength results for plates with barely visible impact damage suggest that the compression-after-impact residual strength is also a function of plate radius. The residual strength of impact-damaged flat plates appears to be lower than the residual strength of the corresponding cylindrically curved plates.

  5. A novel fixation system for sacroiliac dislocation fracture: internal fixation system design and biomechanics analysis.

    PubMed

    Dawei, Tian; Na, Liu; Jun, Lei; Wei, Jin; Lin, Cai

    2013-02-01

    Although there were many different types of fixation techniques for sacroiliac dislocation fracture, the treat remained challenging in posterior pelvic ring injury. The purpose of this study was to evaluate the biomechanical effects of a novel fixation system we designed. 12 human cadavers (L3-pelvic-femora) were used to compare biomechanical stability after reconstruction on the same specimens in four conditions: (1) intact, (2) cable system, (3) plate-pedicle screw system, and (4) cable system and plate-pedicle screw combination system (combination system). Biomechanical testing was performed on a material testing machine for evaluating the stiffness of the pelvic fixation construct in compression and torsion. The cable system and plate-pedicle screw system alone may be insufficient to resist vertical shearing and rotational loads; however the combination system for unstable sacroiliac dislocation fractures provided significantly greater stability than single plate-pedicle or cable fixation system. The novel fixation system for unstable sacroiliac dislocation fractures produced sufficient stability in axial compression and axial rotation test in type C pelvic ring injuries. It may also offer a better solution for sacroiliac dislocation fractures. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Modal parameter identification of a compression-loaded CFRP stiffened plate and correlation with its buckling behaviour

    NASA Astrophysics Data System (ADS)

    Chaves-Vargas, M.; Dafnis, A.; Reimerdes, H.-G.; Schröder, K.-U.

    2015-10-01

    In order to study the dynamic response and the buckling behaviour of several load-carrying structural components of civil aircraft when subjected to transient load scenarios such as gusts or a landing impact, a generic mid-size aircraft is defined within the European research project DAEDALOS. From this aircraft, several sections or panels in different regions such as wing, vertical tailplane and fuselage are defined. The stiffened carbon-fibre-reinforced plastic (CFRP) plate investigated within the present work represents a simplified version of the wing panel selected from the generic aircraft. As part of the current work, the buckling behaviour and the modal properties of the stiffened plate under the effect of a static in-plane compression load are studied. This is accomplished by means of a test series including quasi-static buckling tests and an experimental modal analysis (EMA). One of the key objectives pursued is the correlation of the modal properties to the buckling behaviour by studying the relationship between the natural frequencies of the stiffened plate and its corresponding buckling load. The experimental work is verified by a finite element analysis.

  7. High-speed laser-launched flyer impacts studied with ultrafast photography and velocimetry

    DOE PAGES

    Banishev, Alexandr A.; Shaw, William L.; Bassett, Will P.; ...

    2016-02-16

    Pulsed lasers can launch thin metal foils at km s -1, but for precision measurements in shock compression science and shock wave spectroscopy, where one-dimensional shock compression is vital, flyer plate impacts with targets must have a high degree of flatness and minimal tilt, and the flyer speeds and impact times at the target must be highly reproducible. We have developed an apparatus that combines ultrafast stroboscopic optical microscopy with photon Doppler velocimetry to study impacts of laser-launched Al and Cu flyer plates with flat, transparent glass targets. The flyer plates were 0.5 mm in diameter, and ranged from 12-100more » μm thick, with flyer speeds up to 6.25 km s -1. The velocity variations over 30-60 launches from the same flyer plate optic can be as low as 0.6%, and the impact time variations can be as low as 0.8 ns. Stroboscopic image streams (reconstructed movies) show uniform, flat impacts with a glass target. As a result, these stroboscopic images can be used to estimate the tilt in the flyer-target impact to be <1mrad.« less

  8. Gas turbine vane platform element

    DOEpatents

    Campbell, Christian X [Oviedo, FL; Schiavo, Anthony L [Oviedo, FL; Morrison, Jay A [Oviedo, FL

    2012-08-28

    A gas turbine CMC shroud plate (48A) with a vane-receiving opening (79) that matches a cross-section profile of a turbine vane airfoil (22). The shroud plate (48A) has first and second curved circumferential sides (73A, 74A) that generally follow the curves of respective first and second curved sides (81, 82) of the vane-receiving opening. Walls (75A, 76A, 77A, 78A, 80, 88) extend perpendicularly from the shroud plate forming a cross-bracing structure for the shroud plate. A vane (22) may be attached to the shroud plate by pins (83) or by hoop-tension rings (106) that clamp tabs (103) of the shroud plate against bosses (105) of the vane. A circular array (20) of shroud plates (48A) may be assembled to form a vane shroud ring in which adjacent shroud plates are separated by compressible ceramic seals (93).

  9. Elastic buckling analysis for composite stiffened panels and other structures subjected to biaxial inplane loads

    NASA Technical Reports Server (NTRS)

    Viswanathan, A. V.; Tamekuni, M.

    1973-01-01

    An exact linear analysis method is presented for predicting buckling of structures with arbitrary uniform cross section. The structure is idealized as an assemblage of laminated plate-strip elements, curved and planar, and beam elements. Element edges normal to the longitudinal axes are assumed to be simply supported. Arbitrary boundary conditions may be specified on any external longitudinal edge of plate-strip elements. The structure or selected elements may be loaded in any desired combination of inplane transverse compression or tension side load and axial compression load. The analysis simultaneously considers all possible modes of instability and is applicable for the buckling of laminated composite structures. Numerical results correlate well with the results of previous analysis methods.

  10. A solution procedure for behavior of thick plates on a nonlinear foundation and postbuckling behavior of long plates

    NASA Technical Reports Server (NTRS)

    Stein, M.; Stein, P. A.

    1978-01-01

    Approximate solutions for three nonlinear orthotropic plate problems are presented: (1) a thick plate attached to a pad having nonlinear material properties which, in turn, is attached to a substructure which is then deformed; (2) a long plate loaded in inplane longitudinal compression beyond its buckling load; and (3) a long plate loaded in inplane shear beyond its buckling load. For all three problems, the two dimensional plate equations are reduced to one dimensional equations in the y-direction by using a one dimensional trigonometric approximation in the x-direction. Each problem uses different trigonometric terms. Solutions are obtained using an existing algorithm for simultaneous, first order, nonlinear, ordinary differential equations subject to two point boundary conditions. Ordinary differential equations are derived to determine the variable coefficients of the trigonometric terms.

  11. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    PubMed

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate constructs and the unlocked IM nail were significantly less with a 50% saw cut depth. Plate fixation was superior to IM nail fixation in limiting the opening of a simulated midtibial stress fracture, and anterior-posterior placement of the plate was an important variable for this construct. Results from these tests can help guide the selection of fixation hardware for patients requiring surgical treatment for a midtibial stress fracture. © 2016 The Author(s).

  12. Risk of bile duct cancer among printing workers exposed to 1,2-dichloropropane and/or dichloromethane.

    PubMed

    Sobue, Tomotaka; Utada, Mai; Makiuchi, Takeshi; Ohno, Yuko; Uehara, Shinichiro; Hayashi, Tomoshige; Sato, Kyoko Kogawa; Endo, Ginji

    2015-01-01

    We conducted a retrospective cohort study to examine the risk of bile duct cancer among current and former workers in the offset color proof printing department at a printing company in Osaka, Japan. Standardized incidence ratios (SIRs) between January 1, 1985, and December 31, 2012, were estimated for the cumulative years of exposure to two chemicals, dichloromethane (DCM) and 1,2-dichloropropane (1,2-DCP), using the national incidence level as a reference. In addition, we examined risk patterns by the calendar year in which observation started. Among 106 workers with a total of 1,452.4 person-years of exposure, 17 bile duct cancer cases were observed, resulting in an estimated overall SIR of 1,132.5 (95% confidence interval (CI): 659.7-1,813.2). The SIR was 1,319.9 (95% CI: 658.9-2,361.7) for those who were exposed to both DCM and 1,2-DCP, and it was 1,002.8 (95% CI: 368.0-2,182.8) for those exposed to 1,2-DCP only. SIRs tended to increase according to years of exposure to 1,2-DCP but not DCM when a 5-year lag time was assumed. The SIRs were higher for the cohorts in which observation started in 1993-2000, particularly in cohorts in which it started in 1996-1999, compared with those in which it started before or after 1993-2000. We observed an extraordinarily high risk of bile duct cancer among the offset color proof printing workers. Elevated risk may be related to cumulative exposure to 1,2-DCP, but there remains some possibility that a portion of the risk is due to other unidentified substances.

  13. Genetic variants in the PIWI-piRNA pathway gene DCP1A predict melanoma disease-specific survival.

    PubMed

    Zhang, Weikang; Liu, Hongliang; Yin, Jieyun; Wu, Wenting; Zhu, Dakai; Amos, Christopher I; Fang, Shenying; Lee, Jeffrey E; Li, Yi; Han, Jiali; Wei, Qingyi

    2016-12-15

    The Piwi-piRNA pathway is important for germ cell maintenance, genome integrity, DNA methylation and retrotransposon control and thus may be involved in cancer development. In this study, we comprehensively analyzed prognostic roles of 3,116 common SNPs in PIWI-piRNA pathway genes in melanoma disease-specific survival. A published genome-wide association study (GWAS) by The University of Texas M.D. Anderson Cancer Center was used to identify associated SNPs, which were later validated by another GWAS from the Harvard Nurses' Health Study and Health Professionals Follow-up Study. After multiple testing correction, we found that there were 27 common SNPs in two genes (PIWIL4 and DCP1A) with false discovery rate < 0.2 in the discovery dataset. Three tagSNPs (i.e., rs7933369 and rs508485 in PIWIL4; rs11551405 in DCP1A) were replicated. The rs11551405 A allele, located at the 3' UTR microRNA binding site of DCP1A, was associated with an increased risk of melanoma disease-specific death in both discovery dataset [adjusted Hazards ratio (HR) = 1.66, 95% confidence interval (CI) = 1.21-2.27, p =1.50 × 10 -3 ] and validation dataset (HR = 1.55, 95% CI = 1.03-2.34, p = 0.038), compared with the C allele, and their meta-analysis showed an HR of 1.62 (95% CI, 1.26-2.08, p =1.55 × 10 -4 ). Using RNA-seq data from the 1000 Genomes Project, we found that DCP1A mRNA expression levels increased significantly with the A allele number of rs11551405. Additional large, prospective studies are needed to validate these findings. © 2016 UICC.

  14. Changes in highly sensitive alpha-fetoprotein for the prediction of the outcome in patients with hepatocellular carcinoma after hepatectomy.

    PubMed

    Toyoda, Hidenori; Kumada, Takashi; Tada, Toshifumi; Ito, Takanori; Maeda, Atsuyuki; Kaneoka, Yuji; Kagebayashi, Chiaki; Satomura, Shinji

    2014-06-01

    We investigated changes in highly sensitive lens culinaris agglutinin A-reactive fraction of alpha-fetoprotein (hsAFP-L3) measured using a novel method and its predictive ability for prognosis in patients with hepatocellular carcinoma (HCC) who underwent curative hepatectomy, comparing to other HCC tumor markers, that is, AFP, des-gamma-carboxy prothrombin (DCP), and AFP-L3 measured with conventional method (cAFP-L3). AFP, DCP, and AFP-L3 including both cAFP-L3 and hsAFP-L3 were measured before and after curative hepatectomy in 187 patients. The percentage of patients with elevated tumor marker levels pre- and postoperatively was compared, and recurrence-free and overall survival rates were analyzed based on changes in tumor markers. The percentages of patients with elevated AFP, DCP, and cAFP-L3 decreased postoperatively. In contrast, the percentage of patients with elevated hsAFP-L3 did not decrease postoperatively. Both recurrence-free and overall survival rates were significantly lower in patients whose tumor marker levels remained elevated postoperatively than patients without tumor marker elevation postoperatively. Recurrence-free and overall survival rates of patients in whom hsAFP-L3 became elevated postoperatively despite normal preoperative hsAFP-L3 levels were significantly lower than those of patients with normal hsAFP-L3 postoperatively, and were similar to those of patients with persistent elevation. Preoperative elevations of AFP, DCP, and cAFP normalized in many patients postoperatively, but not for hsAFP-L3. The elevation of hsAFP-L3 identifies patients with poor prognosis despite the normalization of AFP and DCP. © 2014 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  15. Heterogeneous electro-Fenton using modified iron-carbon as catalyst for 2,4-dichlorophenol degradation: influence factors, mechanism and degradation pathway.

    PubMed

    Zhang, Chao; Zhou, Minghua; Ren, Gengbo; Yu, Xinmin; Ma, Liang; Yang, Jie; Yu, Fangke

    2015-03-01

    Modified iron-carbon with polytetrafluoroethylene (PTFE) was firstly investigated as heterogeneous electro-Fenton (EF) catalyst for 2,4-dichlorophenol (2,4-DCP) degradation in near neutral pH condition. The catalyst was characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD), and the effects of some important operating parameters such as current intensity and pH on the 2,4-DCP degradation were investigated. After the catalyst modification with 20% PTFE, the degradation performance maintained well with much lower iron leaching, and at current intensity 100 mA, initial pH 6.7, catalyst loading 6 g/L, the degradation efficiency of 2,4-DCP could exceed 95% within 120 min treatment. Two-stage pseudo first-order kinetics of 2,4-DCP degradation was observed, including a slow anodic oxidation stage (first-stage) and much faster heterogeneous EF oxidation (second-stage), in which the automatic drop of pH in the first-stage initiated the Fe(2+) release from micro-electrolysis and thus benefited to the subsequent EF reaction. Aromatic intermediates such as 3,5-dichlorocatechol, 4,6-dichlororesorcinol and 2-chlorohydroquinone were detected by GC-MS. Oxalic acid, acetic acid, formic acid and Cl(-) were quantified by ion chromatograph. Based on these analysis as well as the detection of H₂O₂ and OH, a possible mechanism and degradation pathway for 2,4-DCP were proposed. This work demonstrated that such a heterogeneous EF using cheap modified Fe-C catalyst was promising for organic wastewater treatment in initial neutral pH condition. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Measurement of the residual stress distribution in a thick pre-stretched aluminum plate

    NASA Astrophysics Data System (ADS)

    Yuan, S. X.; Li, X. Q.; M, S.; Zhang, Y. C.; Gong, Y. D.

    2008-12-01

    Thick pre-stretched aluminum alloy plates are widely used in aircraft, while machining distortion caused by initial residual stress release in thick plates is a common and serious problem. To reduce the distortion, the residual stress distribution in thick plate must be measured. According to the characteristics of the thick pre-stretched aluminum alloy plate, based the elastic mechanical theory, this article deduces the modified layer-removal strain method adapting two different strain situations, which are caused by tensile and compressive stress. To validate this method, the residual stresses distribution along the thick direction of plate 2D70T351 is measured by this method, it is shown that the new method deduced in this paper is simple and accurate, and is very useful in engineering.

  17. Buckling analysis for structural sections and stiffened plates reinforced with laminated composites.

    NASA Technical Reports Server (NTRS)

    Viswanathan, A. V.; Soong, T.-C.; Miller, R. E., Jr.

    1972-01-01

    A classical buckling analysis is developed for stiffened, flat plates composed of a series of linked flat plate and beam elements. Plates are idealized as multilayered orthotropic elements; structural beads and lips are idealized as beams. The loaded edges of the stiffened plate are simply supported and the conditions at the unloaded edges can be prescribed arbitrarily. The plate and beam elements are matched along their common junctions for displacement continuity and force equilibrium in an exact manner. Offsets between elements are considered in the analysis. Buckling under uniaxial compressive load for plates, sections and stiffened plates is investigated. Buckling loads are found as the lowest of all possible general and local failure modes and the mode shape is used to determine whether buckling is a local or general instability. Numerical correlations with existing analysis and test data for plates, sections and stiffened plates including boron-reinforced structures are discussed. In general, correlations are reasonably good.

  18. Polonium-210 levels in different environmental samples.

    PubMed

    Fonollosa, E; Peñalver, A; Aguilar, C; Borrull, F

    2015-12-01

    Polonium-210 is analysed in different samples which can be affected by the presence of a dicalcium phosphate plant (DCP). Particularly, it was determined in sludge samples from a drinking water treatment plant located downstream of the phosphate plant. From the obtained results, it was not possible to establish a correlation with the industrial activities carried out in the DCP plant since the measured activities were comparable to the reported in the literature for normal soils. This isotope was also monitored in different biota species (as mussels) taken also downstream of the DCP, and the potential risk of their ingestion by calculating the total effective doses was evaluated. As a result, it is important to highlight that the ingestion of these mussels does not constitute a risk for the population since the found doses were lower than the values published by UNSCEAR.

  19. Comparison of Spall Pullback Signals and X-ray Tomography Analysis in Copper

    NASA Astrophysics Data System (ADS)

    Gard, Marcie; Russell, Rod; Hanna, Romy; Bless, Stephan; InstituteAdvanced Technology Collaboration; Department of Geological Sciences-UT Austin Collaboration

    2011-06-01

    Spall experiments were conducted on electrolytic tough pitch C110 copper plates. Flyer plates half the target-plate thickness were launched with a single-stage compressed-gas gun. Pullback signals were measured with a photonic Doppler velocimeter (PDV). Spall stresses were determined and found to be about 1 GPa. In addition, damage on the spall plane for samples that failed to separate a spall plate was characterized by x-ray tomography. The paper will include a description of threshold damage. The threshold for appearance of a pullback signal corresponded to the initiation of tensile damage, not formation of a spall separation plane.

  20. Liver Rapid Reference Set Application: Hiro Yamada - Wako (2011) — EDRN Public Portal

    Cancer.gov

    Measure clinical effectiveness of AFP-L3 and DCP for early detection of HCC in patient samples collected prospectively during surveillance. However since such samples are not readily available in the USA the reference set samples are well characterized and studied, gaining access to these samples will allow Wako to quickly measure clinical effectiveness of AFP-L3 and DCP in detecting early HCC.

  1. Efficient Wideband Numerical Simulations for Nanostructures Employing a Drude-Critical Points (DCP) Dispersive Model.

    PubMed

    Ren, Qiang; Nagar, Jogender; Kang, Lei; Bian, Yusheng; Werner, Ping; Werner, Douglas H

    2017-05-18

    A highly efficient numerical approach for simulating the wideband optical response of nano-architectures comprised of Drude-Critical Points (DCP) media (e.g., gold and silver) is proposed and validated through comparing with commercial computational software. The kernel of this algorithm is the subdomain level discontinuous Galerkin time domain (DGTD) method, which can be viewed as a hybrid of the spectral-element time-domain method (SETD) and the finite-element time-domain (FETD) method. An hp-refinement technique is applied to decrease the Degrees-of-Freedom (DoFs) and computational requirements. The collocated E-J scheme facilitates solving the auxiliary equations by converting the inversions of matrices to simpler vector manipulations. A new hybrid time stepping approach, which couples the Runge-Kutta and Newmark methods, is proposed to solve the temporal auxiliary differential equations (ADEs) with a high degree of efficiency. The advantages of this new approach, in terms of computational resource overhead and accuracy, are validated through comparison with well-known commercial software for three diverse cases, which cover both near-field and far-field properties with plane wave and lumped port sources. The presented work provides the missing link between DCP dispersive models and FETD and/or SETD based algorithms. It is a competitive candidate for numerically studying the wideband plasmonic properties of DCP media.

  2. USDI DCS technical support: Mississippi Test Facility

    NASA Technical Reports Server (NTRS)

    Preble, D. M.

    1975-01-01

    The objective of the technical support effort is to provide hardware and data processing support to DCS users so that application of the system may be simply and effectively implemented. Technical support at Mississippi Test Facility (MTF) is concerned primarily with on-site hardware. The first objective of the DCP hardware support was to assure that standard measuring apparatus and techniques used by the USGS could be adapted to the DCS. The second objective was to try to standardize the miscellaneous variety of parameters into a standard instrument set. The third objective was to provide the necessary accessories to simplify the use and complement the capabilities of the DCP. The standard USGS sites have been interfaced and are presently operating. These sites are stream gauge, ground water level and line operated quality of water. Evapotranspiration, meteorological and battery operated quality of water sites are planned for near future DCP operation. Three accessories which are under test or development are the Chu antenna, solar power supply and add-on memory. The DCP has proven to be relatively easy to interface with many monitors. The large antenna is awkward to install and transport. The DCS has met the original requirements well; it has and is proving that an operation, satellite-based data collection system is feasible.

  3. Removal of 2,4-dichlorophenol and pentachlorophenol from waters by sorption using coal fly ash from a Portuguese thermal power plant.

    PubMed

    Estevinho, Berta N; Martins, Isabel; Ratola, Nuno; Alves, Arminda; Santos, Lúcia

    2007-05-08

    Chlorophenols are one of the most important groups of priority pollutants, due to their high toxicity, mutagenicity and carcinogenicity. Although activated carbon has been the preferred choice for the removal of such pollutants from wastewaters, the search for cheaper alternative sorbents became common in the last years. Fly ash, a by-product from coal burning power plants, has a surface composition that may enable the sorption of specific organic compounds. Therefore, this feasibility study presents the optimization of the operating parameters of a fixed-bed column containing fly ash particles, percolated by aqueous solutions of 2,4-dichlorophenol (2,4-DCP) and pentachlorophenol (PCP) with concentrations of 1 and 100 microg/ml. Both chlorophenols were analysed by gas chromatography with electron capture detection (GC-ECD), after solid-phase microextraction (SPME), with limits of detection (LODs) of 7.28 microg/l for 2,4-DCP and 1.76 microg/l for PCP. Removal efficiencies above 99% were obtained for an initial concentration of 10 microg/ml of chlorophenols. Column saturation was achieved after 7h of continuous operation for 2,4-DCP and 10h for the PCP for feed levels of 10 microg/ml. Fly ash exhibited more affinity towards the sorption of PCP, in comparison to 2,4-DCP.

  4. Relationship between compatibilizer and yield strength of PLA/PP Blend

    NASA Astrophysics Data System (ADS)

    Jariyakulsith, Pattanun; Puajindanetr, Somchai

    2018-01-01

    The aim of this research is to study the relationship between compatibilizer and yield strength of polylactic acid (PLA) and polypropylene (PP) blend. The PLA is blended with PP (PLA/PP) at the ratios of 70/30, 50/50 and 30/70. In addition, (1) polypropylene grafted maleic anhydride (PP-g-MAH) as a compatibilizer at 0.3 and 0.7 part per hundred of PLA/PP resin (phr) and (2) dicumyl peroxide (DCP) being an initiator at 0.03 and 0.07 phr are added in each composition. Yield strength is characterized to study the interaction between compatibilizer, initiator and yield strength by using experimental design of multilevel full factorial. The results show that (1) the yield strength of PLA/PP blend are increased after addition of compatibilizer. Because the adding of PP-g-MAH and DCP resulted in improving compatibility between PLA and PP. (2) there are interaction between PP-g-MAH and DCP that have affected the final properties of PLA/PP blend. The highest yield strength of 27.68 MPa is provided at the ratio of 70/30 blend by using the 0.3 phr of PP-g-MAH and 0.03 phr of DCP. Linear regression model is fitted and follow the assumptions of normal distribution.

  5. Application of response surface methodology (RSM) for optimisation of COD, NH3-N and 2,4-DCP removal from recycled paper wastewater in a pilot-scale granular activated carbon sequencing batch biofilm reactor (GAC-SBBR).

    PubMed

    Muhamad, Mohd Hafizuddin; Sheikh Abdullah, Siti Rozaimah; Mohamad, Abu Bakar; Abdul Rahman, Rakmi; Hasan Kadhum, Abdul Amir

    2013-05-30

    In this study, the potential of a pilot-scale granular activated carbon sequencing batch biofilm reactor (GAC-SBBR) for removing chemical oxygen demand (COD), ammoniacal nitrogen (NH3-N) and 2,4-dichlorophenol (2,4-DCP) from recycled paper wastewater was assessed. For this purpose, the response surface methodology (RSM) was employed, using a central composite face-centred design (CCFD), to optimise three of the most important operating variables, i.e., hydraulic retention time (HRT), aeration rate (AR) and influent feed concentration (IFC), in the pilot-scale GAC-SBBR process for recycled paper wastewater treatment. Quadratic models were developed for the response variables, i.e., COD, NH3-N and 2,4-DCP removal, based on the high value (>0.9) of the coefficient of determination (R(2)) obtained from the analysis of variance (ANOVA). The optimal conditions were established at 750 mg COD/L IFC, 3.2 m(3)/min AR and 1 day HRT, corresponding to predicted COD, NH3-N and 2,4-DCP removal percentages of 94.8, 100 and 80.9%, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. The important role of polyvinylpyrrolidone and Cu on enhancing dechlorination of 2,4-dichlorophenol by Cu/Fe nanoparticles: Performance and mechanism study

    NASA Astrophysics Data System (ADS)

    Fang, Liping; Xu, Cuihong; Zhang, Wenbin; Huang, Li-Zhi

    2018-03-01

    The important role of polyvinylpyrrolidone (PVP) and Cu on the reductive dechlorination of 2,4-dichlorophenol (2,4-DCP) by Cu/Fe bimetal nanoparticles has been investigated. The synthesized PVP coated Cu/Fe bimetal nanoparticles with different Cu/Fe ratios were systematically characterized by FTIR, XRD, TEM and magnetic hysteresis loops. The Cu/Fe ratio and the PVP loading were optimized for dechlorination performance, and the optimum ratio of PVP to Cu/Fe was found to be 0.35 and the content of Cu in Cu/Fe nanoparticles was 41%. The presence of PVP as a dispersant/stabilizer results in a highly-dispersed Cu/Fe NPs and increase the reactivity of Cu/Fe NPs for 2,4-DCP removal. The dechlorination rate was enhanced at lower pH and higher temperature conditions. The presence of humic acid, PO43-, NO3-, SO42- leads to a slightly decreased removal efficiency of 2,4-DCP. The magnetic property of PVP-Cu/Fe nanoparticles allows rapid magnetic separation of the catalysts after reaction. A galvanic corrosion model was proposed where iron corrodes and transfers electrons to Cu-rich catalytic regions of the nanoparticles, and finally accelerating the reduction efficiency of 2,4-DCP.

  7. Quasi-isentropic compression using compressed water flow generated by underwater electrical explosion of a wire array

    NASA Astrophysics Data System (ADS)

    Gurovich, V.; Virozub, A.; Rososhek, A.; Bland, S.; Spielman, R. B.; Krasik, Ya. E.

    2018-05-01

    A major experimental research area in material equation-of-state today involves the use of off-Hugoniot measurements rather than shock experiments that give only Hugoniot data. There is a wide range of applications using quasi-isentropic compression of matter including the direct measurement of the complete isentrope of materials in a single experiment and minimizing the heating of flyer plates for high-velocity shock measurements. We propose a novel approach to generating quasi-isentropic compression of matter. Using analytical modeling and hydrodynamic simulations, we show that a working fluid composed of compressed water, generated by an underwater electrical explosion of a planar wire array, might be used to efficiently drive the quasi-isentropic compression of a copper target to pressures ˜2 × 1011 Pa without any complex target designs.

  8. The Elasto-Plastic Stability of Plates

    NASA Technical Reports Server (NTRS)

    Ilyushin, A. A.

    1947-01-01

    This article explains results developed from the following research: 'The Stability of Plates and Shells beyond the Elastic Limit.' A significant improvement is found in the derivation of the relations between the stress factors and the strains resulting from the instability of plates and shells. In a strict analysis, the problem reduces to the solution of two simultaneous nonlinear partial differential equations of the fourth order in the deflection and stress function, and in the approximate analysis to a single linear equation of the Bryan type. Solutions are given for the special cases of a rectangular plate buckling into a cylindrical form, and of an arbitrarily shaped plate under uniform compression. These solutions indicate that the accuracy obtained by the approximate method is satisfactory.

  9. Piezoelectric film load cell robot collision detector

    DOEpatents

    Lembke, J.R.

    1988-03-15

    A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are dowelled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector. 3 figs.

  10. Piezoelectric film load cell robot collision detector

    DOEpatents

    Lembke, John R.

    1989-04-18

    A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are dowelled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector.

  11. Piezoelectric film load cell robot collision detector

    DOEpatents

    Lembke, J.R.

    1989-04-18

    A piezoelectric load cell which can be utilized for detecting collisions and obstruction of a robot arm end effector includes a force sensing element of metallized polyvinylidene fluoride (PVDF) film. The piezoelectric film sensing element and a resilient support pad are clamped in compression between upper and lower plates. The lower plate has a central recess in its upper face for supporting the support pad and sensing element, while the upper plate has a corresponding central projection formed on its lower face for bearing on the sensing element and support pad. The upper and lower plates are doweled together for concentric alignment and screwed together. The upper and lower plates are also adapted for mounting between the robot arm wrist and end effector. 3 figs.

  12. End plate assembly having a two-phase fluid-filled bladder and method for compressing a fuel cell stack

    DOEpatents

    Carlstrom, Jr., Charles M.

    2001-01-01

    An end plate assembly is disclosed for use in a fuel cell assembly in which the end plate assembly includes a housing having a cavity, and a bladder receivable in the cavity and engageable with the fuel cell stack. The bladder includes a two-phase fluid having a liquid portion and a vapor portion. Desirably, the two-phase fluid has a vapor pressure between about 100 psi and about 600 psi at a temperature between about 70 degrees C. to about 110 degrees C.

  13. Operative treatment of sternal fractures.

    PubMed

    Al-Qudah, Abdullah

    2006-10-01

    Four patients with displaced sternal fractures complained of intractable pain following road traffic accidents. They all had bone deformities, but only one had associated traumatic injuries. All patients underwent operative reduction and fixation of the fractured sternum using a T-shaped compression-tension stainless steel plate and screws. Pain relief was often dramatic and all patients progressed to sternal union. None required reoperation. No infections occurred. Two plates have subsequently been removed. On follow-up, all patients had excellent results. Sternal plating, which is based on the tension-band principle, is an effective treatment for displaced sternal fractures.

  14. A diffuse plate boundary model for Indian Ocean tectonics

    NASA Technical Reports Server (NTRS)

    Wiens, D. A.; Demets, C.; Gordon, R. G.; Stein, S.; Argus, D.

    1985-01-01

    It is suggested that motion along the virtually aseismic Owen fracture zone is negligible, so that Arabia and India are contained within a single Indo-Arabian plate divided from the Australian plate by a diffuse boundary. The boundary is a zone of concentrated seismicity and deformation commonly characterized as 'intraplate'. The rotation vector of Australia relative to Indo-Arabia is consistent with the seismologically observed 2 cm/yr of left-lateral strike-slip along the Ninetyeast Ridge, north-south compression in the Central Indian Ocean, and the north-south extension near Chagos.

  15. Present-day stress field in subduction zones: Insights from 3D viscoelastic models and data

    NASA Astrophysics Data System (ADS)

    Petricca, Patrizio; Carminati, Eugenio

    2016-01-01

    3D viscoelastic FE models were performed to investigate the impact of geometry and kinematics on the lithospheric stress in convergent margins. Generic geometries were designed in order to resemble natural subduction. Our model predictions mirror the results of previous 2D models concerning the effects of lithosphere-mantle relative flow on stress regimes, and allow a better understanding of the lateral variability of the stress field. In particular, in both upper and lower plates, stress axes orientations depend on the adopted geometry and axes rotations occur following the trench shape. Generally stress axes are oriented perpendicular or parallel to the trench, with the exception of the slab lateral tips where rotations occur. Overall compression results in the upper plate when convergence rate is faster than mantle flow rate, suggesting a major role for convergence. In the slab, along-strike tension occurs at intermediate and deeper depths (> 100 km) in case of mantle flow sustaining the sinking lithosphere and slab convex geometry facing mantle flow or in case of opposing mantle flow and slab concave geometry facing mantle flow. Along-strike compression is predicted in case of sustaining mantle flow and concave slabs or in case of opposing mantle flow and convex slabs. The slab stress field is thus controlled by the direction of impact of mantle flow onto the slab and by slab longitudinal curvature. Slab pull produces not only tension in the bending region of subducted plate but also compression where upper and lower plates are coupled. A qualitative comparison between results and data in selected subductions indicates good match for South America, Mariana and Tonga-Kermadec subductions. Discrepancies, as for Sumatra-Java, emerge due to missing geometric (e.g., occurrence of fault systems and local changes in the orientation of plate boundaries) and rheological (e.g., plasticity associated with slab bending, anisotropy) complexities in the models.

  16. Tectonic evolution of the North Patagonian Andes (41°-44° S) through recognition of syntectonic strata

    NASA Astrophysics Data System (ADS)

    Echaurren, A.; Folguera, A.; Gianni, G.; Orts, D.; Tassara, A.; Encinas, A.; Giménez, M.; Valencia, V.

    2016-05-01

    The North Patagonian fold-thrust belt (41°-44° S) is characterized by a low topography, reduced crustal thickness and a broad lateral development determined by a broken foreland system in the retroarc zone. This particular structural system has not been fully addressed in terms of the age and mechanisms that built this orogenic segment. Here, new field and seismic evidence of syntectonic strata constrain the timing of the main deformational stages, evaluating the prevailing crustal regime for the different mountain domains through time. Growth strata and progressive unconformities, controlled by extensional or compressive structures, were recognized in volcanic and sedimentary rocks from the cordilleran to the extra-Andean domain. These data were used to construct a balanced cross section, whose deep structure was investigated through a thermomechanical model that characterizes the upper plate rheology. Our results indicate two main compressive stages, interrupted by an extensional relaxation period. The first contractional stage in the mid-Cretaceous inverted Jurassic-Lower Cretaceous half graben systems, reactivating the western Cañadón Asfalto rift border ~ 500 km away from the trench, at a time of arc foreland expansion. For this stage, available thermochronological data reveal forearc cooling episodes, and global tectonic reconstructions indicate mid-ocean ridge collisions against the western edge of an upper plate with rapid trenchward displacement. Widespread synextensional volcanism is recognized throughout the Paleogene during plate reorganization; retroarc Paleocene--Eocene flare up activity is interpreted as product of a slab rollback, and fore-to-retroarc Oligocene slab/asthenospheric derived products as an expression of enhanced extension. The second stage of mountain growth occurred in Miocene time associated with Nazca Plate subduction, reaching nearly the same amplitude than the first compressive stage. Extensional weakening of the upper plate predating the described contractional stages appears as a necessary condition for abnormal lateral propagation of deformation.

  17. The many impacts of building mountain belts on plate tectonics and mantle flow

    NASA Astrophysics Data System (ADS)

    Yamato, Philippe; Husson, Laurent

    2015-04-01

    During the Cenozoic, the number of orogens on Earth increased. This observation readily indicates that in the same time, compression in the lithosphere became gradually more and more important. Such an increase of stresses in the lithosphere can impact on plate tectonics and mantle dynamics. We show that mountain belts at plate boundaries increasingly obstruct plate tectonics, slowing down and reorienting their motions. In turn, this changes the dynamic and kinematic surface conditions of the underlying flowing mantle. Ultimately, this modifies the pattern of mantle flow. This forcing could explain many first order features of Cenozoic plate tectonics and mantle flow. Among these, one can cite the compression of passive margins, the important variations in the rates of spreading at oceanic ridges, or the initiation of subduction, the onset of obduction, for the lithosphere. In the mantle, such change in boundary condition redesigns the pattern of mantle flow and, consequently, the oceanic lithosphere cooling. In order to test this hypothesis we first present thermo-mechanical numerical models of mantle convection above which a lithosphere rests. Our results show that when collision occurs, the mantle flow is highly modified, which leads to (i) increasing shear stresses below the lithosphere and (ii) to a modification of the convection style. In turn, the transition between a 'free' convection (mobile lid) and an 'upset' convection (stagnant -or sluggish- lid) highly impacts the dynamics of the lithosphere at the surface of the Earth. Thereby, on the basis of these models and a variety of real examples, we show that on the other side of a collision zone, passive margins become squeezed and can undergo compression, which may ultimately evolve into subduction or obduction. We also show that much further, due to the blocking of the lithosphere, spreading rates decrease at the ridge, a fact that may explain a variety of features such as the low magmatism of ultraslow spreading ridges or the departure of slow spreading ridges from the half-space cooling model.

  18. Locking Compression Plate in Distal Femoral Intra-Articular Fractures: Our Experience

    PubMed Central

    Kiran Kumar, G. N.; Sharma, Gaurav; Farooque, Kamran; Sharma, Vijay; Ratan, Ratnav; Yadav, Sanjay; Lakhotia, Devendra

    2014-01-01

    Background. Intra-articular fractures of distal femur present a huge surgical challenge. The aim of this study is to evaluate functional outcome, fracture healing, and the complications of distal femoral intra-articular fractures using locking compression plates. Material and Methods. We reviewed 46 distal femoral fractures treated with distal femoral locking compression plates between 2009 to 2012. There were 36 men and 10 women with mean age of 35 years (range 20–72). More than half of the patients were of type C3 (AO classification) and had been caused by high energy trauma with associated injuries. Results. 2 patients were lost to follow-up. Of the remaining 44 patients, the mean follow-up period was 25 months (range 18–36). The mean time for radiological union was 12 weeks (range 10–18) except 2 patients which had gone for nonunion. At the latest follow up ROM >120° is noted in 32 patients, 90–120 in 10 patients, and 70–90 in 2 patients. 38 patients (86%) had good/excellent outcome. Conclusion. Use of standard lateral approach for simple intra-articular distal femoral fractures (C1) and transarticular/minimally invasive techniques for complex intra-articular fractures (C2/C3) results in improved exposure of the knee joint and better union rates with low incidence of bone grafting. PMID:27355064

  19. Dynamic Response of Vertebral Elements Related to USAF Injury

    DTIC Science & Technology

    1978-02-01

    eventual loss of mucopolysaccharide matrix from both the hyaline cartilage end plates and fibro- cartilage annulUS« resulting in increased cell...In other studies conducted during this contract period, seven adult Rhesus monkeys have been subjected to implantations of calibrated stress...fibroblasts; 2. Loss of cells from and compression of the circular regions lying between the cartilage end plates and nucleus; 3. Altered staining and

  20. The Effects of Applied Stress and Sensitization on the Passive Film Stability of Al-Mg Alloys

    DTIC Science & Technology

    2013-06-01

    and residual tensile and compressive stresses impact the passive layer film and the material’s electrochemistry. Sample plates of AA5083 were...electrochemistry. Sample plates of AA5083 were sensitized to different levels to promote the formation of intergranular β phase (Al3Mg2). The...41  A.  MATERIAL PROCESSING: FABRICATION AND APPLIED STRESSES OF TEST SAMPLES

  1. Low-Stress Upper Plate Near Subduction Zones and Implications for Temporal Changes in Loading Forces

    NASA Astrophysics Data System (ADS)

    Wang, K.; Hu, Y.; Yoshida, K.

    2016-12-01

    Subduction megathrusts are weak, often with effective friction coefficients as low as 0.03. Consequently, differential stress (S1 - S3) in the nearby upper plate is low. Compression due to plate coupling and tension due to gravity are in a subtle balance that can be tipped by small perturbations. For example, the 2011 M=9 Tohoku-oki earthquake, which has a rupture-zone-average stress drop of only a few MPa, switched offshore margin-normal stress from compression to tension and affected seismicity pattern and stress directions of various parts of the land area. The low differential stress is also reflected in spatial variations of stresses, such as with changes in topography. In the Andes, crustal earthquake focal mechanisms change from thrust-faulting in low-elevation areas to normal-faulting in high-elevation areas. Given the lack of evidence for a pervasively weak crust, the low differential stress may indicate that in general the crust near subduction zones is not critically stressed. If so, crustal earthquakes do not represent pervasive failure but only local failure due to stress, material, and fluid pressure heterogeneity. If distributed permanent deformation that creates topography is not the norm, it either happens in brief episodes or took place in the past. The outer wedge may enter a compressively or extensionally critical state due to coseismic strengthening or weakening, respectively, of the shallow megathrust in largest interplate earthquakes. Temporal changes in loading forces must occur also at much larger temporal and spatial scales in response to changes in the nature of the subducting plate and other tectonic conditions. We propose that submarine wedges and high topography in the upper plate attain their geometry in geologically brief episodes of high differential stress. They normally stay in a low-stress stable state, but their geometry often reflects high-stress episodes of critical states in the past. In other words, rocks have a sustained memory for the most traumatic moments. Except for the weaker outer wedge, the upper plate does not switch from one critical state to another in megathrust earthquake cycles, such as from compressional failure to gravitational collapse.

  2. Catalytic bipolar interconnection plate for use in a fuel cell

    DOEpatents

    Lessing, Paul A.

    1996-01-01

    A bipolar interconnection plate for use between adjacent fuel cell units in a stacked fuel cell assembly. Each plate is manufactured from an intermetallic composition, examples of which include NiAl or Ni.sub.3 Al which can catalyze steam reforming of hydrocarbons. Distributed within the intermetallic structure of the plate is a ceramic filler composition. The plate includes a first side with gas flow channels therein and a second side with fuel flow channels therein. A protective coating is applied to the first side, with exemplary coatings including strontium-doped or calcium-doped lanthanum chromite. To produce the plate, Ni and Al powders are combined with the filler composition, compressed at a pressure of about 10,000-30,000 psi, and heated to about 600.degree.-1000.degree. C. The coating is then applied to the first side of the completed plate using liquid injection plasma deposition or other deposition techniques.

  3. Catalytic bipolar interconnection plate for use in a fuel cell

    DOEpatents

    Lessing, P.A.

    1996-03-05

    A bipolar interconnection plate is described for use between adjacent fuel cell units in a stacked fuel cell assembly. Each plate is manufactured from an intermetallic composition, examples of which include NiAl or Ni{sub 3}Al which can catalyze steam reforming of hydrocarbons. Distributed within the intermetallic structure of the plate is a ceramic filler composition. The plate includes a first side with gas flow channels therein and a second side with fuel flow channels therein. A protective coating is applied to the first side, with exemplary coatings including strontium-doped or calcium-doped lanthanum chromite. To produce the plate, Ni and Al powders are combined with the filler composition, compressed at a pressure of about 10,000--30,000 psi, and heated to about 600--1000 C. The coating is then applied to the first side of the completed plate using liquid injection plasma deposition or other deposition techniques. 6 figs.

  4. In situ X-Ray Diffraction of Shock-Compressed Fused Silica

    NASA Astrophysics Data System (ADS)

    Tracy, Sally June; Turneaure, Stefan J.; Duffy, Thomas S.

    2018-03-01

    Because of its widespread applications in materials science and geophysics, SiO2 has been extensively examined under shock compression. Both quartz and fused silica transform through a so-called "mixed-phase region" to a dense, low compressibility high-pressure phase. For decades, the nature of this phase has been a subject of debate. Proposed structures include crystalline stishovite, another high-pressure crystalline phase, or a dense amorphous phase. Here we use plate-impact experiments and pulsed synchrotron x-ray diffraction to examine the structure of fused silica shock compressed to 63 GPa. In contrast to recent laser-driven compression experiments, we find that fused silica adopts a dense amorphous structure at 34 GPa and below. When compressed above 34 GPa, fused silica transforms to untextured polycrystalline stishovite. Our results can explain previously ambiguous features of the shock-compression behavior of fused silica and are consistent with recent molecular dynamics simulations. Stishovite grain sizes are estimated to be ˜5 - 30 nm for compression over a few hundred nanosecond time scale.

  5. Twyman effect mechanics in grinding and microgrinding.

    PubMed

    Lambropoulos, J C; Xu, S; Fang, T; Golini, D

    1996-10-01

    In the Twyman effect (1905), when one side of a thin plate with both sides polished is ground, the plate bends: The ground side becomes convex and is in a state of compressive residual stress, described in terms of force per unit length (Newtons per meter) induced by grinding, the stress (Newtons per square meter) induced by grinding, and the depth of the compressive layer (micrometers). We describe and correlate experiments on optical glasses from the literature in conditions of loose abrasive grinding (lapping at fixed nominal pressure, with abrasives 4-400 μm in size) and deterministic microgrinding experiments (at a fixed infeed rate) conducted at the Center for Optics Manufacturing with bound diamond abrasive tools (with a diamond size of 3-40 μm, embedded in metallic bond) and loose abrasive microgrinding (abrasives of less than 3 μm in size). In brittle grinding conditions, the grinding force and the depth of the compressive layer correlate well with glass mechanical properties describing the fracture process, such as indentation crack size. The maximum surface residual compressive stress decreases, and the depth of the compressive layer increases with increasing abrasive size. In lapping conditions the depth of the abrasive grain penetration into the glass surface scales with the surface roughness, and both are determined primarily by glass hardness and secondarily by Young's modulus for various abrasive sizes and coolants. In the limit of small abrasive size (ductile-mode grinding), the maximum surface compressive stress achieved is near the yield stress of the glass, in agreement with finite-element simulations of indentation in elastic-plastic solids.

  6. Passive margins getting squeezed in the mantle convection vice

    NASA Astrophysics Data System (ADS)

    Yamato, Philippe; Husson, Laurent; Becker, Thorsten W.; Pedoja, Kevin

    2014-05-01

    Passive margins often exhibit uplift, exhumation and tectonic inversion. We speculate that the compression in the lithosphere gradually increased during the Cenozoic. In the same time, the many mountain belts at active margins that accompany this event seem readily witness this increase. However, how that compression increase affects passive margins remains unclear. In order to address this issue, we design a 2D viscous numerical model wherein a lithospheric plate rests above a weaker mantle. It is driven by a mantle conveyor belt, alternatively excited by a lateral downwelling on one side, an upwelling on the other side, or both simultaneously. The lateral edges of the plate are either free or fixed, representing the cases of free convergence, and collision or slab anchoring, respectively. This distinction changes the upper boundary condition for mantle circulation and, as a consequence, the stress field. Our results show that between these two regimes, the flow pattern transiently evolves from a free-slip convection mode towards a no-slip boundary condition above the upper mantle. In the second case, the lithosphere is highly stressed horizontally and deforms. For an equivalent bulk driving force, compression increases drastically at passive margins provided that upwellings are active. Conversely, if downwellings alone are activated, compression occurs at short distances from the trench and extension prevails elsewhere. These results are supported by Earth-like 3D spherical models that reveal the same pattern, where active upwellings are required to excite passive margins compression. These results support the idea that compression at passive margins, is the response to the underlying mantle flow, that is increasingly resisted by the Cenozoic collisions.

  7. 4D-CT scans reveal reduced magnitude of respiratory liver motion achieved by different abdominal compression plate positions in patients with intrahepatic tumors undergoing helical tomotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Yong, E-mail: hu.yong@zs-hospital.sh.cn; Zhou,

    Purpose: While abdominal compression (AC) can be used to reduce respiratory liver motion in patients receiving helical tomotherapy for hepatocellular carcinoma, the nature and extent of this effect is not well described. The purpose of this study was to evaluate the changes in magnitude of three-dimensional liver motion with abdominal compression using four-dimensional (4D) computed tomography (CT) images of several plate positions. Methods: From January 2012 to October 2015, 72 patients with intrahepatic carcinoma and divided into four groups underwent 4D-CT scans to assess respiratory liver motion. Of the 72 patients, 19 underwent abdominal compression of the cephalic area betweenmore » the subxiphoid and umbilicus (group A), 16 underwent abdominal compression of the caudal region between the subxiphoid area and the umbilicus (group B), 11 patients underwent abdominal compression of the caudal umbilicus (group C), and 26 patients remained free breathing (group D). 4D-CT images were sorted into ten-image series, according to the respiratory phase from the end inspiration to the end expiration, and then transferred to treatment planning software. All liver contours were drawn by a single physician and confirmed by a second physician. Liver relative coordinates were automatically generated to calculate the liver respiratory motion in different axial directions to compile the 10 ten contours into a single composite image. Differences in respiratory liver motion were assessed with a one-way analysis of variance test of significance. Results: The average respiratory liver motion in the Y axial direction was 4.53 ± 1.16, 7.56 ± 1.30, 9.95 ± 2.32, and 9.53 ± 2.62 mm in groups A, B, C, and D, respectively, with a significant change among the four groups (p < 0.001). Abdominal compression was most effective in group A (compression plate on the subxiphoid area), with liver displacement being 2.53 ± 0.93, 4.53 ± 1.16, and 2.14 ± 0.92 mm on the X-, Y-, and Z-axes, respectively. There was no significant difference in respiratory liver motion between group C (displacement: 3.23 ± 1.47, 9.95 ± 2.32, and 2.92 ± 1.10 mm on the X-, Y-, and Z-axes, respectively) and group D (displacement: 3.35 ± 1.55, 9.53 ± 2.62, and 3.35 ± 1.73 mm on the X-, Y-, and Z-axes, respectively). Abdominal compression was least effective in group C (compression on caudal umbilicus), with liver motion in this group similar to that of free-breathing patients (group D). Conclusions: 4D-CT scans revealed significant liver motion control via abdominal compression of the subxiphoid area; however, this control of liver motion was not observed with compression of the caudal umbilicus. The authors, therefore, recommend compression of the subxiphoid area in patients undergoing external radiotherapy for intrahepatic carcinoma.« less

  8. Comparison of the Mechanical Characteristics of a Universal Small Biplane Plating Technique Without Compression Screw and Single Anatomic Plate With Compression Screw.

    PubMed

    Dayton, Paul; Ferguson, Joe; Hatch, Daniel; Santrock, Robert; Scanlan, Sean; Smith, Bret

    2016-01-01

    To better understand the mechanical characteristics of biplane locked plating in small bone fixation, the present study compared the stability under cyclic cantilever loading of a 2-plate locked biplane (BPP) construct without interfragmentary compression with that of a single-plate locked construct with an additional interfragmentary screw (SPS) using surrogate bone models simulating Lapidus arthrodesis. In static ultimate plantar bending, the BPP construct failed at significantly greater load than did the SPS construct (556.2 ± 37.1 N versus 241.6 ± 6.3 N, p = .007). For cyclic failure testing in plantar bending at a 180-N starting load, the BPP construct failed at a significantly greater number of cycles (158,322 ± 50,609 versus 13,718 ± 10,471 cycles) and failure load (242.5 ± 25.0 N versus 180.0 ± 0.0 N) than the SPS construct (p = .002). For cyclic failure testing in plantar bending at a 120-N starting load, the results were not significantly different between the BPP and SPS constructs for the number of cycles (207,646 ± 45,253 versus 159,334 ± 69,430) or failure load (205.0 ± 22.4 N versus 185.0 ± 33.5 N; p = .300). For cyclic testing with 90° offset loading (i.e., medial to lateral bending) at a 120-N starting load, all 5 BPP constructs (tension side) and 2 of the 5 SPS constructs reached 250,000 cycles without failure. Overall, the present study found the BPP construct to have superior or equivalent stability in multiplanar orientations of force application in both static and fatigue testing. Thus, the concept of biplane locked plating, using 2 low profile plates and unicortical screw insertion, shows promise in small bone fixation, because it provides consistent stability in multiplanar orientations, making it universally adaptable to many clinical situations. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Comparative study suggests that human bone morphogenetic proteins have no influence on the outcome of operative treatment of aseptic clavicle non-unions.

    PubMed

    von Rüden, Christian; Morgenstern, Mario; Friederichs, Jan; Augat, Peter; Hackl, Simon; Woltmann, Alexander; Bühren, Volker; Hierholzer, Christian

    2016-11-01

    The purpose of this study was to evaluate the clinical and radiological outcome following compression plate fixation in combination with autologous bone grafting, with and without additional application of recombinant human bone morphogenetic protein (rhBMP) for treatment of aseptic clavicle non-union. Between April 2004 and April 2015, 82 patients were treated for clavicle fracture and had developed aseptic clavicle non-union. Seventy-three out of 82 patients were available for follow-up at least one year after revision surgery; among them, 27 women and 46 men, with a median age of 49 (range, 19-86) years. Forty-five patients received compression plate osteosynthesis with autologous bone grafting, and 28 patients obtained compression plate fixation with autologous bone grafting and additional application of rhBMP-2 (3/28 patients) or rhBMP-7 (25/28 patients). Seventy out of 73 non-unions (96 %) healed within 12 months after revision surgery. Functional outcome according to the DASH Outcome Measure (with rhBMP, 33.16 ± 1.17 points; without rhBMP, 30.58 ± 2.12 points [mean ± SEM]; p = 0.81), non-union healing (p = 0.86), time interval between revision surgery and bone healing (p = 0.37), as well as post-operative complications, did not demonstrate relevant differences between the treatment groups and were not age-dependent. Functional and radiological results demonstrate that successful healing of aseptic clavicle non-union is dependent on radical resection of non-union tissue, restoration of length of the shoulder girdle and application of stable locking-plate osteosynthesis in combination with autologous bone grafting, but not dependent on application of additional rhBMP.

  10. DCP-collected absolute target reflectance signatures assist accurate interpretation of ERTS-1 imagery

    NASA Technical Reports Server (NTRS)

    Weber, F. P.

    1973-01-01

    Data collection platforms (DCP's) are being used at a Black Hills, South Dakota, test site (MMC 226A) to record radiometric measurements needed to determine solar and atmospheric parameters that affect ERTS-1 multispectral scanner radiance measurements. A total of 72 channels of analog data transmitted from an unattended ground truth site via three DCP's at least six times a day. The system has operated with only minor problems since September, sending forth daily measurements of biophysical responses and atmospheric conditions. Comparisons of scene radiance data calculated from ERTS images with that measured on the ground show the image-measured values to be 35 percent higher for the green channel and 20 percent higher for the red channel for the same scene targets. Radiance values for channels 6 and 7 are nearly the same from the ground data and from the imagery.

  11. Sensitive fluorescence on-off probes for the fast detection of a chemical warfare agent mimic.

    PubMed

    Khan, Muhammad Shar Jhahan; Wang, Ya-Wen; Senge, Mathias O; Peng, Yu

    2018-01-15

    Two highly sensitive probes bearing a nucleophilic imine moiety have been utilized for the selective detection of chemical warfare agent (CWA) mimics. Diethyl chlorophosphate (DCP) was used as mimic CWAs. Both iminocoumarin-benzothiazole-based probes not only demonstrated a remarkable fluorescence ON-OFF response and good recognition, but also exhibited fast response times (10s) along with color changes upon addition of DCP. Limits of detection for the two sensors 1 and 2 were calculated as 0.065μM and 0.21μM, respectively, which are much lower than most other reported probes. These two probes not only show high sensitivity and selectivity in solution, but can also be applied for the recognition of DCP in the gas state, with significant color changes easily observed by the naked eye. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Modeling and simulation of clutch pressure plate casting using alternate materials

    NASA Astrophysics Data System (ADS)

    Madhuraj, H. N.; Bharath, M. R.

    2018-04-01

    Clutch Pressure Plate is a stress bearing component in the clutch assembly. Cast iron alloys like FG300, G2500 are commonly used for clutch pressure plate castings. These materials have high compressive strength, low tensile strength & no ductility but these cost high for the manufacturers. There is a need for alternate material so as to reduce cost, defects in castings without losing the life and effectiveness of the clutch plate. The work carried out here is modeling the clutch pressure plate using CAD tool. And then the casting process is simulated by casting simulation for fluid flow and solidification analysis by trying alternate material. Here the castability of the alternate material En-Gjs-400-15 and the commonly used material FG300 for the clutch pressure plate component is analyzed by designing and optimizing a proper gating system.

  13. Terminal-shock and restart control of a Mach 2.5, axisymmetric, mixed compression inlet with 40 percent internal contraction. [wind tunnel tests

    NASA Technical Reports Server (NTRS)

    Baumbick, R. J.

    1974-01-01

    Results of experimental tests conducted on a supersonic, mixed-compression, axisymmetric inlet are presented. The inlet is designed for operation at Mach 2.5 with a turbofan engine (TF-30). The inlet was coupled to either a choked orifice plate or a long duct which had a variable-area choked exit plug. Closed-loop frequency responses of selected diffuser static pressures used in the terminal-shock control system are presented. Results are shown for Mach 2.5 conditions with the inlet coupled to either the choked orifice plate or the long duct. Inlet unstart-restart traces are also presented. High-response inlet bypass doors were used to generate an internal disturbance and also to achieve terminal-shock control.

  14. Analysis of Shock Compression of Strong Single Crystals With Logarithmic Thermoelastic-Plastic Theory

    DTIC Science & Technology

    2014-05-01

    Royal Society of London Series A, 465, 307–334. Clayton, J. (2010a). Modeling nonlinear electromechanical behavior of shocked silicon carbide . Journal...and fourth-order longitudinal elastic constants by shock compression techniques–application to sapphire and fused quartz. Journal of the Acoustical...Vogler, T., & Clayton, J. (2008). Heterogeneous deformation and spall of an extruded tungsten alloy: Plate impact experiments and crystal plasticity

  15. Biomechanical Study of the Fixation Strength of Anteromedial Plating for Humeral Shaft Fractures.

    PubMed

    Zheng, Yin-Feng; Zhou, Jun-Lin; Wang, Xiao-Hong; Shan, Lei; Liu, Yang

    2016-08-05

    Open reduction and internal fixation with plate and screws are the gold standard for the surgical treatment of humeral shaft fractures, this study was to compare the mechanical properties of anteromedial, anterolateral, and posterior plating for humeral shaft fractures. A distal third humeral shaft fracture model was constructed using fourth-generation sawbones (#3404, composite bone). A total of 24 sawbones with a distal third humeral shaft fracture was randomly divided into three Groups: A, B, and C (n = 8 in each group) for anteromedial, anterolateral, and posterior plating, respectively. All sawbones were subjected to horizontal torsional fatigue tests, horizontal torsional and axial compressive fatigue tests, four-point bending fatigue tests in anteroposterior (AP) and mediolateral (ML) directions and horizontal torsional destructive tests. In the horizontal torsional fatigue tests, the mean torsional angle amplitude in Groups A, B, and C were 6.12°, 6.53°, and 6.81°. In horizontal torsional and axial compressive fatigue tests, the mean torsional angle amplitude in Groups A, B, and C were 5.66°, 5.67°, and 6.36°. The mean plate displacement amplitude was 0.05 mm, 0.08 mm, and 0.10 mm. Group A was smaller than Group C (P < 0.05). In AP four-point bending fatigue tests, the mean plate displacement amplitude was 0.16 mm, 0.13 mm, and 0.20 mm. Group B was smaller than Group C (P < 0.05). In ML four-point bending fatigue tests, the mean plate displacement amplitude were 0.16 mm, 0.19 mm, and 0.17 mm. In horizontal torsional destructive tests, the mean torsional rigidity in Groups A, B, and C was 0.82, 0.75, and 0.76 N·m/deg. The yielding torsional angle was 24.50°, 25.70°, and 23.86°. The mean yielding torque was 18.46, 18.05, and 16.83 N·m, respectively. Anteromedial plating was superior to anterolateral or posterior plating in all mechanical tests except in AP four-point bending fatigue tests compared to the anterolateral plating group. We can suggest that anteromedial plating is a clinically safe and effective way for humeral shaft fractures.

  16. The Collapse and Spreading of Sundaland (SE Asia); evolution and Boundary Conditions

    NASA Astrophysics Data System (ADS)

    Pubellier, Manuel; Morley, Christopher

    2014-05-01

    By the end of Mesozoic times Sundaland (the continental core of SE Asia) was an elevated area composed of granite and metamorphic basement on the rims; which suffered collapse and incipient extension, whereas the central part was stable. Most of the basins opened inside evolved since the Late Cretaceous in a manner that may be correlated to the conditions of the subduction in the Sunda Trench. The Sundaland promontory was surrounded by a large subduction zone, except in the north and was a free boundary in the Early Cenozoic. Starting from the Palaeogene, fractures initiated during the India Eurasia collision, and rifting began along large faults (mostly N-S and NNW-SSE strike-slip). The basins remained in a continental fluvio-lacustrine or shallow marine environment for a long time and some are marked by extremely stretched crust (Phu Khanh, Natuna, N. Makassar) or even reached the ocean floor spreading stage (Celebes, Flores). Western Sundaland was a combination of basin opening and strike-slip transpressional deformation. The configuration suggests a free boundary particularly to the east (trench pull associated with the Proto-South China Sea subduction; Java-Sulawesi trench subduction rollback). In the Early Miocene, Australian blocks reached the Sunda subduction zone and imposed local shortening in the south and southeast, whereas the western part was free from compression after the Indian continent had moved away to the north. This suggests an important coupling of the Sunda Plate with the Indo-Australian Plate both to SE and NW, possibly further west rollback had ceased in the Java-Sumatra subduction zone, and compressional stress was being transferred northwards across the plate boundary. The internal compression is expressed to the south by shortening which is transmitted as far as the Malay basin. In the Late Miocene, most of the Sunda Plate was under compression, except the tectonically isolated Andaman Sea and the Damar basins. In the Pliocene, collision north of Australia propagated toward the north and west causing subduction reversal and compression in the short-lived Damar Basin. Docking of the Philippine Plate confined the eastern side of Sundaland and created local compression and uplift such as in NW Borneo, Palawan and Taiwan. Transpressional deformation created extensive folding, strike-slip faulting and uplift of the Central Basin and Arakan Yoma in Myanmar. Minor inversion affected many Thailand rift basins. All the other basins record subsidence. The uplift is responsible for gravity tectonics where thick sediments were accumulated (Sarawak, NE Luconia, Bangladesh wedge). We conclude that the evolution of the basin is closely controlled by the absence or the arrival of continental crust at the boundary of Sundaland.

  17. Autonomous geodynamics of the Pamir-Tien Shan junction zone from seismology data

    NASA Astrophysics Data System (ADS)

    Lukk, A. A.; Shevchenko, V. I.; Leonova, V. G.

    2015-11-01

    The geodynamics of the Tajik Depression, the junction zone of the Pamirs and Tien Shan, is typically considered in the context of plate tectonic concept, which implies intense subhorizontal compression of the zone resulting from the subduction of the Indian and Eurasian lithospheric plates. This convergence has been reliably confirmed by the GPS measurements. However, the joint analysis of the geological structure, seismicity, and geodimeter measurements conducted during a few years at the Garm geodynamical testing site of the Schmidt Institute of Physics of the Earth, Russian Academy of Sciences, demonstrates a widening of the Tajik Depression instead of its shortening, as should be expected from the subhorizontal compression predominant in the present-day stress-state of this region. This conclusion, together with the data from the other regions, suggests that, along with the plate tectonic mechanisms, there are also other, local, autonomous drivers that contribute to the tectogenesis of this region. Besides, the probable existence of these autonomous sources within the Tajik Depression directly follows from the seismology data. Among them is the crustal spreading within the depression suggested by the seismotectonic displacements in the focal mechanisms of the earthquakes. These displacements are directed in different azimuths off the axial's most subsided part of the depression at a depth of 20-30 km. Above this region the distribution of seismotectonic deformations (STD) is chaotic. This pattern of deformation is barely accounted for by a simple model of subhorizontal compression of the Earth's crust in the region. In our opinion, these features of the seismotectonic deformation in the crust within the studied part of the Tajik Depression is probably associated with the gain in the volume of the rocks due to the inflow of the additional material, which is supplied from the bottom crust or upper mantle by the deep fluids. This increase in the rock volume produces the state of horizontal compression (or, more exactly, outward all-round pressure). We suggest considering the subvertical pillar-like object, identified as a cluster of the earthquake hypocenters in the northern part of the region with chaotic STD, as one of the probable channels of fluid supply. This structure' plane is isometric and has a diameter of about 20 km. It stretches downwards to a depth of 40 km, where the seismicity ceases. The suggested scenario of generation of the outward all-round pressure (autonomous geodynamics) can be considered as an independent driver of tectogenesis along with the traditional mechanisms relating the emergence of the stressstate of subhorizontal compression to the plate-tectonic convergence of the Eurasian and Indian lithospheric plates.

  18. Identification of pneumonia and influenza deaths using the death certificate pipeline

    PubMed Central

    2012-01-01

    Background Death records are a rich source of data, which can be used to assist with public surveillance and/or decision support. However, to use this type of data for such purposes it has to be transformed into a coded format to make it computable. Because the cause of death in the certificates is reported as free text, encoding the data is currently the single largest barrier of using death certificates for surveillance. Therefore, the purpose of this study was to demonstrate the feasibility of using a pipeline, composed of a detection rule and a natural language processor, for the real time encoding of death certificates using the identification of pneumonia and influenza cases as an example and demonstrating that its accuracy is comparable to existing methods. Results A Death Certificates Pipeline (DCP) was developed to automatically code death certificates and identify pneumonia and influenza cases. The pipeline used MetaMap to code death certificates from the Utah Department of Health for the year 2008. The output of MetaMap was then accessed by detection rules which flagged pneumonia and influenza cases based on the Centers of Disease and Control and Prevention (CDC) case definition. The output from the DCP was compared with the current method used by the CDC and with a keyword search. Recall, precision, positive predictive value and F-measure with respect to the CDC method were calculated for the two other methods considered here. The two different techniques compared here with the CDC method showed the following recall/ precision results: DCP: 0.998/0.98 and keyword searching: 0.96/0.96. The F-measure were 0.99 and 0.96 respectively (DCP and keyword searching). Both the keyword and the DCP can run in interactive form with modest computer resources, but DCP showed superior performance. Conclusion The pipeline proposed here for coding death certificates and the detection of cases is feasible and can be extended to other conditions. This method provides an alternative that allows for coding free-text death certificates in real time that may increase its utilization not only in the public health domain but also for biomedical researchers and developers. Trial Registration This study did not involved any clinical trials. PMID:22569097

  19. Modeling of orthotropic plate fracture under impact load using various strength criteria

    NASA Astrophysics Data System (ADS)

    Radchenko, Andrey; Krivosheina, Marina; Kobenko, Sergei; Radchenko, Pavel; Grebenyuk, Grigory

    2017-01-01

    The paper presents the comparative analysis of various tensor multinomial criteria of strength for modeling of orthotropic organic plastic plate fracture under impact load. Ashkenazi, Hoffman and Wu strength criteria were used. They allowed fracture modeling of orthotropic materials with various compressive and tensile strength properties. The modeling of organic plastic fracture was performed numerically within the impact velocity range of 700-1500 m/s.

  20. Non Destructive Seal Testing Polymeric Tray

    DTIC Science & Technology

    2006-10-01

    School of Enviromental and Biological Science Rutgers, The State University of New Jersey New Brunswick, New Jersey 08903 Principal Investigator...plate to accept new tray • Insert tray • Push “Continue” button • Lower upper compression plate and hold in position (80 psig) • Raise bottom...John J. Kingman Rd. Fort Belvoir, VA 22060-6221 Contractor: Rutgers, The State University of New Jersey THE CENTER FOR ADVANCED FOOD TECHNOLOGY

  1. Progress Towards a Cartesian Cut-Cell Method for Viscous Compressible Flow

    NASA Technical Reports Server (NTRS)

    Berger, Marsha; Aftosmis, Michael J.

    2011-01-01

    The proposed paper reports advances in developing a method for high Reynolds number compressible viscous flow simulations using a Cartesian cut-cell method with embedded boundaries. This preliminary work focuses on accuracy of the discretization near solid wall boundaries. A model problem is used to investigate the accuracy of various difference stencils for second derivatives and to guide development of the discretization of the viscous terms in the Navier-Stokes equations. Near walls, quadratic reconstruction in the wall-normal direction is used to mitigate mesh irregularity and yields smooth skin friction distributions along the body. Multigrid performance is demonstrated using second-order coarse grid operators combined with second-order restriction and prolongation operators. Preliminary verification and validation for the method is demonstrated using flat-plate and airfoil examples at compressible Mach numbers. Simulations of flow on laminar and turbulent flat plates show skin friction and velocity profiles compared with those from boundary-layer theory. Airfoil simulations are performed at laminar and turbulent Reynolds numbers with results compared to both other simulations and experimental data

  2. Hexavalent Chrome Free Coatings for Electronics Electromagnetic Interference (EMI) Shielding Effectiveness (SE) Interim Test Report

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt R.

    2015-01-01

    Test specimen configuration was provided by Parker Chomerics. The EMI gasket used in this project was Cho-Seal 6503E. Black oxide alloy steel socket head bolts were used to hold the plates together. Non-conductive spacers were used to control the amount of compression on the gaskets. The following test fixture specifications were provided by Parker Chomerics. The CHO-TP09 test plate sets selected for this project consist of two aluminum plates manufactured to the specifications detailed in CHO­-TP09. The first plate, referred to as the test frame, is illustrated in Figure 1. The test frame is designed with a cutout in the center and two alternating bolt patterns. One pattern is used to bolt the test frame to the corresponding test cover plate (Figure 2), forming a test plate set. The second pattern accepts the hardware used to mount the fully assembled test plate set to the main adapter plate (Figure 3).

  3. Iberian plate kinematics: A jumping plate boundary between Eurasia and Africa

    USGS Publications Warehouse

    Srivastava, S.P.; Schouten, Hans; Roest, W.R.; Klitgord, Kim D.; Kovacs, L.C.; Verhoef, J.; Macnab, R.

    1990-01-01

    THE rotation of Iberia and its relation to the formation of the Pyrenees has been difficult to decipher because of the lack of detailed sea-floor spreading data, although several models have been proposed1-7. Here we use detailed aeromagnetic measurements from the sea floor offshore of the Grand Banks of Newfoundland to show that Iberia moved as part of the African plate from late Cretaceous to mid-Eocene time, with a plate boundary extending westward from the Bay of Biscay. When motion along this boundary ceased, a boundary linking extension in the King's Trough to compression along the Pyrenees came into existence. Finally, since the late Oligocene, Iberia has been part of the Eurasian plate, with the boundary between Eurasia and Africa situated along the Azores-Gibraltar fracture zone.

  4. Annual Report 1984.

    DTIC Science & Technology

    1985-01-01

    equipped with data collection platforms (DCP) by the end of FY 1985. (b) Communication. The DCP’s transmit the remote gaging station data over the...activated 78 platforms in FY 84 bringing the total number of operating stations to 85. Plans are to activate seven more platforms in FY 85. c. Acoustic... Platforms . The total program cost for FY 1984 is shown in Table VI-3. The total program cost for FY 1985 will be $172,720. (2) National Weather Service

  5. GOES data-collection system instrumentation, installation, and maintenance manual

    USGS Publications Warehouse

    Blee, J.W.; Herlong, H.E.; Kaufmann, C.D.; Hardee, J.H.; Field, M.L.; Middelburg, R.F.

    1986-01-01

    The purpose of the manual is to describe the installation, operation, and maintenance of Geostationary Operational Environmental Satellite (GOES) data collection platforms (DCP's) and associated equipment. This manual is not a substitute for DCP manufacturers ' manuals but is additional material that describes the application of data-collection platforms in the Water Resources Division. Power supplies, encoders, antennas, Mini Monitors, voltage analog devices, and the installation of these at streamflow-gaging stations are discussed in detail. (USGS)

  6. Quantitative determination and toxicity evaluation of 2,4-dichlorophenol using poly(eosin Y)/hydroxylated multi-walled carbon nanotubes modified electrode

    PubMed Central

    Zhu, Xiaolin; Zhang, Kexin; Wang, Chengzhi; Guan, Jiunian; Yuan, Xing; Li, Baikun

    2016-01-01

    This study aimed at developing simple, sensitive and rapid electrochemical approach to quantitatively determine and assess the toxicity of 2,4-dichlorophenol (2,4-DCP), a priority pollutant and has potential risk to public health through a novel poly(eosin Y, EY)/hydroxylated multi-walled carbon nanotubes composite modified electrode (PEY/MWNTs-OH/GCE). The distinct feature of this easy-fabricated electrode was the synergistic coupling effect between EY and MWNTs-OH that enabled a high electrocatalytic activity to 2,4-DCP. Under optimum conditions, the oxidation peak current enhanced linearly with concentration increasing from 0.005 to 0.1 μM and 0.2 to 40.0 μM, and revealed the detection limit of 1.5 nM. Moreover, the PEY/MWNTs-OH/GCE exhibited excellent electrocatalytic activity toward intracellular electroactive species. Two sensitive electrochemical signals ascribed to guanine/xanthine and adenine/hypoxanthine in human hepatoma (HepG2) cells were detected simultaneously. The sensor was successfully applied to evaluate the toxicity of 2,4-DCP to HepG2 cells. The IC50 values based on the two electrochemical signals are 201.07 and 252.83 μM, respectively. This study established a sensitive platform for the comprehensive evaluation of 2,4-DCP and posed a great potential to simplify environmental toxicity monitoring. PMID:27941912

  7. Polarization Characteristics of Zebra Patterns in Type IV Solar Radio Bursts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaneda, K.; Misawa, H.; Tsuchiya, F.

    The polarization characteristics of zebra patterns (ZPs) in type IV solar bursts were studied. We analyzed 21 ZP events observed by the Assembly of Metric-band Aperture Telescope and Real-time Analysis System between 2010 and 2015 and identified the following characteristics: a degree of circular polarization (DCP) in the range of 0%–70%, a temporal delay of 0–70 ms between the two circularly polarized components (i.e., the right- and left-handed components), and dominant ordinary-mode emission in about 81% of the events. For most events, the relation between the dominant and delayed components could be interpreted in the framework of fundamental plasma emissionmore » and depolarization during propagation, though the values of DCP and delay were distributed across wide ranges. Furthermore, it was found that the DCP and delay were positively correlated (rank correlation coefficient R = 0.62). As a possible interpretation of this relationship, we considered a model based on depolarization due to reflections at sharp density boundaries assuming fundamental plasma emission. The model calculations of depolarization including multiple reflections and group delay during propagation in the inhomogeneous corona showed that the DCP and delay decreased as the number of reflections increased, which is consistent with the observational results. The dispersive polarization characteristics could be explained by the different numbers of reflections causing depolarization.« less

  8. Static Tensile and Transient Dynamic Response of Cracked Aluminum Plate Repaired with Composite Patch - Numerical Study

    NASA Astrophysics Data System (ADS)

    Khalili, S. M. R.; Shariyat, M.; Mokhtari, M.

    2014-06-01

    In this study, the central cracked aluminum plates repaired with two sided composite patches are investigated numerically for their response to static tensile and transient dynamic loadings. Contour integral method is used to define and evaluate the stress intensity factors at the crack tips. The reinforcement for the composite patches is carbon fibers. The effect of adhesive thickness and patch thickness and configuration in tensile loading case and pre-tension, pre-compression and crack length effect on the evolution of the mode I stress intensity factor (SIF) (KI) of the repaired structure under transient dynamic loading case are examined. The results indicated that KI of the central cracked plate is reduced by 1/10 to 1/2 as a result of the bonded composite patch repair in tensile loading case. The crack length and the pre-loads are more effective in repaired structure in transient dynamic loading case in which, the 100 N pre-compression reduces the maximum KI for about 40 %, and the 100 N pre-tension reduces the maximum KI after loading period, by about 196 %.

  9. High precision Hugoniot measurements on statically pre-compressed fluid helium

    NASA Astrophysics Data System (ADS)

    Seagle, Christopher T.; Reinhart, William D.; Lopez, Andrew J.; Hickman, Randy J.; Thornhill, Tom F.

    2016-09-01

    The capability for statically pre-compressing fluid targets for Hugoniot measurements utilizing gas gun driven flyer plates has been developed. Pre-compression expands the capability for initial condition control, allowing access to thermodynamic states off the principal Hugoniot. Absolute Hugoniot measurements with an uncertainty less than 3% on density and pressure were obtained on statically pre-compressed fluid helium utilizing a two stage light gas gun. Helium is highly compressible; the locus of shock states resulting from dynamic loading of an initially compressed sample at room temperature is significantly denser than the cryogenic fluid Hugoniot even for relatively modest (0.27-0.38 GPa) initial pressures. The dynamic response of pre-compressed helium in the initial density range of 0.21-0.25 g/cm3 at ambient temperature may be described by a linear shock velocity (us) and particle velocity (up) relationship: us = C0 + sup, with C0 = 1.44 ± 0.14 km/s and s = 1.344 ± 0.025.

  10. Axisymmetric buckling of the circular graphene sheets with the nonlocal continuum plate model

    NASA Astrophysics Data System (ADS)

    Farajpour, A.; Mohammadi, M.; Shahidi, A. R.; Mahzoon, M.

    2011-08-01

    In this article, the buckling behavior of nanoscale circular plates under uniform radial compression is studied. Small-scale effect is taken into consideration. Using nonlocal elasticity theory the governing equations are derived for the circular single-layered graphene sheets (SLGS). Explicit expressions for the buckling loads are obtained for clamped and simply supported boundary conditions. It is shown that nonlocal effects play an important role in the buckling of circular nanoplates. The effects of the small scale on the buckling loads considering various parameters such as the radius of the plate and mode numbers are investigated.

  11. A comparison of screw insertion torque and pullout strength.

    PubMed

    Ricci, William M; Tornetta, Paul; Petteys, Timothy; Gerlach, Darin; Cartner, Jacob; Walker, Zakiyyah; Russell, Thomas A

    2010-06-01

    Pullout strength of screws is a parameter used to evaluate plate screw fixation strength. However, screw fixation strength may be more closely related to its ability to generate sufficient insertion because stable nonlocked plate-screw fracture fixation requires sufficient compression between plate and bone such that no motion occurs between the plate and bone under physiological loads. Compression is generated by tightening of screws. In osteoporotic cancellous bone, sufficient screw insertion torque may not be generated before screw stripping. The effect of screw thread pitch on generation of maximum insertion torque (MIT) and pullout strength (POS) was investigated in an osteoporotic cancellous bone model and the relationship between MIT and POS was analyzed. Stainless steel screws with constant major (5.0 mm) and minor (2.7 mm) diameters but with varying thread pitches (1, 1.2, 1.5, 1.6, and 1.75 mm) were tested for MIT and POS in a validated osteoporotic surrogate for cancellous bone (density of 160 kg/m(3) [10 lbs/ft(3)]). MIT was measured with a torque-measuring hex driver for screws inserted through a one-third tubular plate. POS was measured after insertion of screws to a depth of 20 mm based on the Standard Specification and Test Methods for Metallic Medical Bone Screws (ASTM F 543-07). Five screws were tested for each failure mode and screw design. The relationship between MIT and compressive force between the plate and bone surrogate was evaluated using pressure-sensitive film. There was a significant difference in mean MIT based on screw pitch (P < 0.0001), whereas POS did not show statistically significant differences among the different screw pitches (P = 0.052). Small screw pitches (1.0 mm and 1.2 mm) had lower MIT and were distinguished from large pitches (1.5 mm, 1.6 mm, and the 1.75 mm) with higher MIT. For POS, only the 1-mm and 1.6-mm pitch screws were found to be different from each other. Linear regression analysis of MIT revealed a moderate correlation to the screw pitch (R(2) = 0.67, P < 0.0001), whereas the analysis of POS suggested no correlation to the screw pitch (R(2) = 0.28, P = 0.006). Pearson correlation analysis indicated no correlation between MIT and POS (P = 0.069, r = -0.37). A linear relationship of increased compression between the plate and bone surrogate was found for increasing screw torque (R(2) = 0.97). These results indicate that the ability of different screw designs to generate high screw insertion torque in a model of osteoporotic cancellous bone is unrelated to their pullout strength. Therefore, extrapolation of results for POS to identify optimal screw design for osteoporotic bone may not be valid. Screw designs that optimize MIT should be sought for fixation in osteoporotic bone.

  12. Characterization of cell mechanical properties by computational modeling of parallel plate compression.

    PubMed

    McGarry, J P

    2009-11-01

    A substantial body of work has been reported in which the mechanical properties of adherent cells were characterized using compression testing in tandem with computational modeling. However, a number of important issues remain to be addressed. In the current study, using computational analyses, the effect of cell compressibility on the force required to deform spread cells is investigated and the possibility that stiffening of the cell cytoplasm occurs during spreading is examined based on published experimental compression test data. The effect of viscoelasticity on cell compression is considered and difficulties in performing a complete characterization of the viscoelastic properties of a cell nucleus and cytoplasm by this method are highlighted. Finally, a non-linear force-deformation response is simulated using differing linear viscoelastic properties for the cell nucleus and the cell cytoplasm.

  13. Detection of ovomucoid-specific low-affinity IgE in infants and its relationship to eczema.

    PubMed

    Kawamoto, Norio; Kamemura, Norio; Kido, Hiroshi; Fukao, Toshiyuki

    2017-06-01

    Allergen-specific low-affinity IgE was previously detected in cord blood by a highly sensitive densely carboxylated protein (DCP) chip, but not by ImmunoCAP. Here, we investigated the presence of low-affinity IgE during the early life of infants and observed its relationship with eczema. We conducted a birth cohort study, collecting sera at birth and 6 and 14 months of age (n = 110). We monitored the ovomucoid (OM)- and egg white (EW)-specific IgE (sIgE) by ImmunoCAP or DCP chip and analyzed the antigen affinity of sIgE by binding inhibition assays in the presence or absence of a mild chaotropic agent, diethyl amine (DEA). The low- and high-affinity OM-sIgEs and sensitization risk factors were analyzed by a multivariate logistic analysis. The OM-sIgE measured by DCP chip significantly correlated with that measured by ImmunoCAP, but some samples assessed as OM-sIgE positive by DCP chip were considered OM-sIgE negative by ImmunoCAP. Binding inhibition analysis after DEA treatment was performed for participants judged as OM-sIgE positive by DCP chip at 14 M. The group assessed as negative for OM- and EW-sIgE by ImmunoCAP at 6 and 14 months showed a larger binding inhibition curve shift after DEA treatment than did the group assessed as positive at these times, indicating the presence of low-affinity sIgE antibodies at 14 months. The logistic regression analysis found that persistent eczema from 6 to 14 months is a significant risk factor for developing high-affinity, but not low-affinity, sIgE. Human infant peripheral blood contains allergen-specific low-affinity sIgE. Persistent eczema is related to the development of high-affinity, but not low-affinity, IgE. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Exploring the use of social network analysis to measure communication between disease programme and district managers at sub-national level in South Africa.

    PubMed

    Kawonga, Mary; Blaauw, Duane; Fonn, Sharon

    2015-06-01

    With increasing interest in maximising synergies between disease control programmes (DCP) and general health services (GHS), methods are needed to measure interactions between DCP and GHS actors. In South Africa, administrative integration reforms make GHS managers at decentralised level (district managers) responsible for the oversight of DCP operations within districts, with DCP managers (programme managers) providing specialist support. The reforms necessitate interdependence, but these actors work together ineffectively. Communication is crucial for joint working, but no research to assess communication between these actors has been done. This study explores the use of social network analysis (SNA) to measure the extent to which programme and district managers in South Africa communicate, using HIV monitoring and evaluation (M&E) as an exemplar. Data were collected from fifty one managers in two provinces during 2010-2011, to measure: a) one-on-one task-related communication - talking about the collation (verification, reporting) and use of HIV data for monitoring HIV interventions; and b) group communication through co-participating in management committees where HIV data are used for monitoring HIV interventions in districts. SNA measures were computed to describe actor centrality, network density (cohesion), and communication within and between respective manager groups. Block modelling was applied to identify management committees that connect respective manager groups. Results show HIV programme managers located at higher level communicated largely amongst themselves as a group (homophily), seldom talked to the district managers to whom they are supposed to provide specialist HIV M&E support, and rarely participated with them in management committees. This research demonstrates the utility of SNA as a tool for measuring the extent of communication between DCP and GHS actors at sub-national level. Actions are needed to bridge observed communication gaps in order to promote collaborative monitoring of HIV programme interventions within districts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Performance evaluation of a granular activated carbon-sequencing batch biofilm reactor pilot plant system used in treating real wastewater from recycled paper industry.

    PubMed

    Muhamad, Mohd Hafizuddin; Sheikh Abdullah, Siti Rozaimah; Mohamad, Abu Bakar; Rahman, Rakmi Abdul; Kadhum, Abdul Amir Hasan

    2012-01-01

    A pilot scale granular activated carbon-sequencing batch biofilm reactor with a capacity of 2.2 m3 was operated for over three months to evaluate its performance treating real recycled paper industry wastewater under different operational conditions. In this study, dissolved air floatation (DAF) and clarifier effluents were used as influent sources of the pilot plant. During the course of the study, the reactor was able to biodegrade the contaminants in the incoming recycled paper mill wastewater in terms of chemical oxygen demand (COD), adsorbable organic halides (AOX; specifically 2,4-dichlorophenol (2,4-DCP)) and ammoniacal nitrogen (NH3-N) removal efficiencies at varying hydraulic retention times (HRTs) of 1-3 days, aeration rates (ARs) of 2.1-3.4 m3/min and influent feed concentration of 40-950 mg COD/l. Percentages of COD, 2,4-DCP and NH3-N removals increased with increasing HRT, resulting in more than 90% COD, 2,4-DCP and NH3-N removals at HRT values above two days. Degradation of COD, 2,4-DCP and NH3-N were seriously affected by variation of ARs, which resulted in significant decrease of COD, 2,4-DCP and NH3-N removals by decreasing ARs from 3.4 m3/min to 2.1 m3/min, varying in the ranges of 24-80%, 6-96% and 5-42%, respectively. In comparison to the clarifier effluent, the treatment performance of DAF effluent, containing high COD concentration, resulted in a higher COD removal of 82%. The use of diluted DAF effluent did not improve significantly the COD removal. Higher NH3-N removal efficiency of almost 100% was observed during operation after maintenance shutdown compared to normal operation, even at the same HRT of one day due to the higher dissolved oxygen concentrations (1-7 mg/l), while no significant difference in COD removal efficiency was observed.

  16. Hip fracture - discharge

    MedlinePlus

    ... or a special metal plate or rod with screws, called compression screws or nails, put in place. Alternatively, you may ... walking as soon as possible. For this reason, it is very important to stay active and follow ...

  17. Variable delivery, fixed displacement pump

    DOEpatents

    Sommars, Mark F.

    2001-01-01

    A variable delivery, fixed displacement pump comprises a plurality of pistons reciprocated within corresponding cylinders in a cylinder block. The pistons are reciprocated by rotation of a fixed angle swash plate connected to the pistons. The pistons and cylinders cooperate to define a plurality of fluid compression chambers each have a delivery outlet. A vent port is provided from each fluid compression chamber to vent fluid therefrom during at least a portion of the reciprocal stroke of the piston. Each piston and cylinder combination cooperates to close the associated vent port during another portion of the reciprocal stroke so that fluid is then pumped through the associated delivery outlet. The delivery rate of the pump is varied by adjusting the axial position of the swash plate relative to the cylinder block, which varies the duration of the piston stroke during which the vent port is closed.

  18. MR-guided fine needle aspiration of breast lesions: Initial experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wald, D.S.; Weinreb, J.C.; Newstead, G.

    1996-01-01

    Fine needle aspiration (FNA) is a minimally invasive procedure that is used to obtain cytologic specimens of suspicious lesions in the breast. The goal of this study was to evaluate the logistics and limitations of MR-guided FNA using a prototype breast localization coil. MR-guided FNAs were attempted on 18 lesions (detected on mammography and/or palpation) in 16 patients. Patients were prone with their compressed mediolaterally between two plates in a circularly polarized RF coil. Lesion position was determined by reference to fiducial makers that corresponded to a grid of holes placed at 5 mm intervals in compression plate. FNA wasmore » performed with a 22G non-ferromagnetic needle. FNA was successful for 11 of 18 lesions (61%). Of the seven unsuccessful cases, there were four in which the lesions were too posteriorly placed to be accessed through the compression plate by the needle. Three cases were too anteriorly placed to be effectively immobilized and, although successfully localized, were insufficiently sampled by the FNA technique. MR-guided FNA is possible using a prototype breast localization device in a select group of patients. Current coil design limits its use in performing MR-guided FNA on the most anteriorly and posteriorly placed breast lesions. Unique requirements of FNA under MR guidance as compared to needle localization and biopsy have been identified. Modifications in localization hardware and cytology aspiration needles should overcome these restrictions. 15 refs., 3 figs.« less

  19. Localisation of deformations of the midfacial complex in subjects with class III malocclusions employing thin-plate spline analysis

    PubMed Central

    SINGH, G. D.; McNAMARA JR, J. A.; LOZANOFF, S.

    1997-01-01

    This study determines deformations of the midface that contribute to a class III appearance, employing thin-plate spline analysis. A total of 135 lateral cephalographs of prepubertal children of European-American descent with either class III malocclusions or a class I molar occlusion were compared. The cephalographs were traced and checked, and 7 homologous landmarks of the midface were identified and digitised. The data sets were scaled to an equivalent size and subjected to Procrustes analysis. These statistical tests indicated significant differences (P<0.05) between the averaged class I and class III morphologies. Thin-plate spline analysis indicated that both affine and nonaffine transformations contribute towards the total spline for the averaged midfacial configuration. For nonaffine transformations, partial warp 3 had the highest magnitude, indicating the large scale deformations of the midfacial configuration. These deformations affected the palatal landmarks, and were associated with compression of the midfacial complex in the anteroposterior plane predominantly. Partial warp 4 produced some vertical compression of the posterior aspect of the midfacial complex whereas partial warps 1 and 2 indicated localised shape changes of the maxillary alveolus region. Large spatial-scale deformations therefore affect the midfacial complex in an anteroposterior axis, in combination with vertical compression and localised distortions. These deformations may represent a developmental diminution of the palatal complex anteroposteriorly that, allied with vertical shortening of midfacial height posteriorly, results in class III malocclusions with a retrusive midfacial profile. PMID:9449078

  20. Balancing Materiel Readiness Risks and Concurrency in Weapon System Acquisition: A Handbook for Program Managers

    DTIC Science & Technology

    1984-07-15

    ftViCCii UWNC COMMAND MIX CM AFT DCP OUTUNC moo ffEOUCST FOR PROGRAM DECISION DRAFT DCP AFSC REVIEW RECOWMEM CATIONS OHI*OC Arse wioc...CS.P3 F16. El*. P» MCA Exhibit 4-6b. EMBEDDED COMPUTER HARDWARE vs. SOFTWARE Exhibit 4-6c. DoD EMBEDDED COMPUTER MARKET 31.J1...the mix of stores carried by that vehicle 6. Anticipated combat tactics employed by the carrying or launching vehicle and its maneuvering

  1. Gene-Environment Interaction and Breast Cancer on Long Island, NY

    DTIC Science & Technology

    2008-05-01

    Report on Human Exposure to Environmental Chemicals, 2005; 6–11-year age group, 2001–2002 survey years; 1999–2000 survey years used for 2,4-DCP and 2,5-DCP...Examination Survey (NHANES) conducted between 1999 and 2002 (Centers for Disease Control and Prevention, 2005). NHANES is designed to collect data on the...The CDC has previ- ously reported concentrations in child partici- pants in the National Health and Nutrition Examination Survey (NHANES) for some

  2. Evaluation of an ERTS-1 data collection platform installed in the Alpine Tundra, Colorado. [for meteorological measurements

    NASA Technical Reports Server (NTRS)

    Barry, R. G.; Clark, J. M.

    1975-01-01

    The communication of data in real-time to users from ground stations in remote areas is a major objective of recent space technology. The data collection system considered uses small battery-operated ground-based transmitters called data collection platforms (DCP). The feasibility of collecting environmental data in extreme cold and windy environments using the ERTS DCP, has been investigated. A summary of the results of an evaluation of the system used is presented.

  3. Development of Curved-Plate Elements for the Exact Buckling Analysis of Composite Plate Assemblies Including Transverse Shear Effects

    NASA Technical Reports Server (NTRS)

    McGowan, David M.; Anderson, Melvin S.

    1998-01-01

    The analytical formulation of curved-plate non-linear equilibrium equations that include transverse-shear-deformation effects is presented. A unified set of non-linear strains that contains terms from both physical and tensorial strain measures is used. Using several simplifying assumptions, linearized, stability equations are derived that describe the response of the plate just after bifurcation buckling occurs. These equations are then modified to allow the plate reference surface to be located a distance z(c), from the centroid surface which is convenient for modeling stiffened-plate assemblies. The implementation of the new theory into the VICONOPT buckling and vibration analysis and optimum design program code is described. Either classical plate theory (CPT) or first-order shear-deformation plate theory (SDPT) may be selected in VICONOPT. Comparisons of numerical results for several example problems with different loading states are made. Results from the new curved-plate analysis compare well with closed-form solution results and with results from known example problems in the literature. Finally, a design-optimization study of two different cylindrical shells subject to uniform axial compression is presented.

  4. Advanced data mining approaches in the assessment of urinary concentrations of bisphenols, chlorophenols, parabens and benzophenones in Brazilian children and their association to DNA damage.

    PubMed

    Rocha, Bruno A; Asimakopoulos, Alexandros G; Honda, Masato; da Costa, Nattane L; Barbosa, Rommel M; Barbosa, Fernando; Kannan, Kurunthachalam

    2018-07-01

    Human exposure to endocrine disrupting chemicals (EDCs) has received considerable attention over the last three decades. However, little is known about the influence of co-exposure to multiple EDCs on effect-biomarkers such as oxidative stress in Brazilian children. In this study, concentrations of 40 EDCs were determined in urine samples collected from 300 Brazilian children of ages 6-14 years and data were analyzed by advanced data mining techniques. Oxidative DNA damage was evaluated from the urinary concentrations of 8-hydroxy-2'-deoxyguanosine (8OHDG). Fourteen EDCs, including bisphenol A (BPA), methyl paraben (MeP), ethyl paraben (EtP), propyl paraben (PrP), 3,4-dihydroxy benzoic acid (3,4-DHB), methyl-protocatechuic acid (OH-MeP), ethyl-protocatechuic acid (OH-EtP), triclosan (TCS), triclocarban (TCC), 2-hydroxy-4-methoxybenzophenone (BP3), 2,4-dihydroxybenzophenone (BP1), bisphenol A bis(2,3-dihydroxypropyl) glycidyl ether (BADGE·2H 2 O), 2,4-dichlorophenol (2,4-DCP), and 2,5-dichlorophenol (2,5-DCP) were found in >50% of the urine samples analyzed. The highest geometric mean concentrations were found for MeP (43.1 ng/mL), PrP (3.12 ng/mL), 3,4-DHB (42.2 ng/mL), TCS (8.26 ng/mL), BP3 (3.71 ng/mL), and BP1 (4.85 ng/mL), and exposures to most of which were associated with personal care product (PCP) use. Statistically significant associations were found between urinary concentrations of 8OHDG and BPA, MeP, 3,4-DHB, OH-MeP, OH-EtP, TCS, BP3, 2,4-DCP, and 2,5-DCP. After clustering the data on the basis of i) 14 EDCs (exposure levels), ii) demography (age, gender and geographic location), and iii) 8OHDG (effect), two distinct clusters of samples were identified. 8OHDG concentration was the most critical parameter that differentiated the two clusters, followed by OH-EtP. When 8OHDG was removed from the dataset, predictability of exposure variables increased in the order of: OH-EtP > OH-MeP > 3,4-DHB > BPA > 2,4-DCP > MeP > TCS > EtP > BP1 > 2,5-DCP. Our results showed that co-exposure to OH-EtP, OH-MeP, 3,4-DHB, BPA, 2,4-DCP, MeP, TCS, EtP, BP1, and 2,5-DCP was associated with DNA damage in children. This is the first study to report exposure of Brazilian children to a wide range of EDCs and the data mining approach further strengthened our findings of chemical co-exposures and biomarkers of effect. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Femoral fracture repair using a locking plate technique in an adult captive polar bear (Ursus maritimus).

    PubMed

    Zimmerman, Dawn M; Dew, Terry; Douglass, Michael; Perez, Edward

    2010-02-01

    To report successful femoral fracture repair in a polar bear. Case report. Female polar bear (Ursus maritimus) 5 years and approximately 250 kg. A closed, complete, comminuted fracture of the distal midshaft femur was successfully reduced and stabilized using a compression plating technique with 2 specialized human femur plates offering axial, rotational, and bending support, and allowing the bone to share loads with the implant. Postoperative radiographs were obtained at 11.5 weeks, 11 months, and 24 months. Bone healing characterized by marked periosteal reaction was evident at 11 months with extensive remodeling evident at 24 months. No complications were noted. Distal mid shaft femoral fracture was reduced, stabilized, and healed in an adult polar bear with a locking plate technique using 2 plates. Previously, femoral fractures in polar bears were considered irreparable. Use of 2 plates applied with a locking plate technique can result in successful fracture repair despite large body weight and inability to restrict postoperative activity.

  6. Deformation and instability of underthrusting lithospheric plates

    NASA Technical Reports Server (NTRS)

    Liu, H.

    1972-01-01

    Models of the underthrusting lithosphere are constructed for the calculation of displacement and deflection. First, a mathematical theory is developed that rigorously demonstrates the elastic instability in the decending lithosphere. The theory states that lithospheric thrust beneath island arcs becomes unstable and suffers deflection as the compression increases. Thus, in the neighborhood of the edges where the lithospheric plate plunges into the asthenosphere and mesosphere its shape will be contorted. Next, the lateral displacement is calculated, and it is shown that, before contortion, the plate will thicken and contract at different positions with the variation in thickness following a parabolic profile. Finally, the depth distribution of the intermediate and deep focus earthquakes is explained in terms of plate buckling and contortion.

  7. Effects of relaxation on the delayed-type hypersensitivity (DTH) reaction to diphenylcyclopropenone (DCP).

    PubMed

    Zachariae, R; Jørgensen, M M; Christensen, S; Bjerring, P

    1997-07-01

    Delayed-type hypersensitivity (DTH) reactions to the experimental allergen diphenylcyclopropenone (DCP) were measured in four groups, which either trained (+) or did not train in relaxation (-) during the sensitization and/or the challenge phase. All groups consisted of high and low hypnotic susceptible subjects. While there were no differences in erythema, the mean induration of the group which trained in relaxation in both the sensitization and the challenge phase (+/+) was significantly greater than that of the group which trained in relaxation in the challenge phase only (-/+). Significant correlations were found between induration and hypnotic susceptibility scores, and between induration and degree of perceived relaxation during challenge. High hypnotic susceptible subjects experienced a higher degree of perceived relaxation and exhibited greater indurative and erythematous DTH reactions to DCP than low hypnotic susceptible subjects in all four experimental conditions. Though the mediating mechanisms remain unclear, our results suggest that relaxation may affect the DTH reaction, and support previous findings of higher psychophysiologic reactivity of high hypnotic susceptible subjects.

  8. Hsp83 loss suppresses proteasomal activity resulting in an upregulation of caspase-dependent compensatory autophagy.

    PubMed

    Choutka, Courtney; DeVorkin, Lindsay; Go, Nancy Erro; Hou, Ying-Chen Claire; Moradian, Annie; Morin, Gregg B; Gorski, Sharon M

    2017-09-02

    The 2 main degradative pathways that contribute to proteostasis are the ubiquitin-proteasome system and autophagy but how they are molecularly coordinated is not well understood. Here, we demonstrate an essential role for an effector caspase in the activation of compensatory autophagy when proteasomal activity is compromised. Functional loss of Hsp83, the Drosophila ortholog of human HSP90 (heat shock protein 90), resulted in reduced proteasomal activity and elevated levels of the effector caspase Dcp-1. Surprisingly, genetic analyses showed that the caspase was not required for cell death in this context, but instead was essential for the ensuing compensatory autophagy, female fertility, and organism viability. The zymogen pro-Dcp-1 was found to interact with Hsp83 and undergo proteasomal regulation in an Hsp83-dependent manner. Our work not only reveals unappreciated roles for Hsp83 in proteasomal activity and regulation of Dcp-1, but identifies an effector caspase as a key regulatory factor for sustaining adaptation to cell stress in vivo.

  9. ERTS-1 data collection systems used to predict wheat disease severities. [Riley County, Kansas

    NASA Technical Reports Server (NTRS)

    Kanemasu, E. T.; Schimmelpfenning, H.; Choy, E. C.; Eversmeyer, M. G.; Lenhert, D.

    1974-01-01

    The author has identified the following significant results. The feasibility of using the data collection system on ERTS-1 to predict wheat leaf rust severity and resulting yield loss was tested. Ground-based data collection platforms (DCP'S), placed in two commercial wheat fields in Riley County, Kansas, transmitted to the satellite such meteorological information as maximum and minimum temperature, relative humidity, and hours of free moisture. Meteorological data received from the two DCP'S from April 23 to 29 were used to estimate the disease progress curve. Values from the curve were used to predict the percentage decrease in wheat yields resulting from leaf rust. Actual decrease in yield was obtained by applying a zinc and maneb spray (5.6 kg/ha) to control leaf rust, then comparing yields of the controlled (healthy) and the noncontrolled (rusted) areas. In each field a 9% decrease in yield was predicted by the DCP-derived data; actual decreases were 12% and 9%.

  10. Enzymatic coupling of 2,4-dichlorophenol to stream fulvic acid in the presence of oxidoreductases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarkar, J.M.; Malcolm, R.L.; Bollag, J.M.

    The coupling {sup 14}C-ring-labelled 2,4-dichlorophenol (2,4-DCP) to stream fulvic acid was investigated in the presence of several oxidoreductases including tyrosinase, peroxidase, and laccases of Rhizoctonia praticola and Trametes vesicolor. During 12-h incubation of the oxidoreductases with {sup 14}C-2, 4-DCP and stream fulvic acid, a substantial amount of the radioactivity was incorporated into fulvic acid. Chromatographic analysis indicated that although a large portion of the radioactivity remained in solution, no unbound {sup 14}C-2,4-DCP was present in the supernatant. The effects of pH, temperature, concentration of fulvic acid, and concentration of enzyme on the coupling processes were studied. The results of thismore » research provide evidence that the enzymatic coupling of certain xenobiotic pollutants to humic substances is an important natural process which must be considered in studies of the fate, reactivity, and persistence of these organic compounds in soils and stream waters.« less

  11. Concepts for improving the damage tolerance of composite compression panels

    NASA Technical Reports Server (NTRS)

    Rhodes, M. D.; Williams, J. G.

    1981-01-01

    The results of an experimental evaluation of graphite-epoxy composite compression panel impact damage tolerance and damage propagation arrest concepts are reported. The tests were conducted on flat plate specimens and blade-stiffened structural panels such as those used in commercial aircraft wings, and the residual strength of damaged specimens and their sensitivity to damage while subjected to in-plane compression loading were determined. Results suggest that matrix materials that fail by delamination have the lowest damage tolerance, and it is concluded that alternative matrix materials with transverse reinforcement to suppress the delamination failure mode and yield the higher-strain value transverse shear crippling mode should be developed.

  12. Heat Transfer in the Turbulent Boundary Layer of a Compressible Gas at High Speeds

    NASA Technical Reports Server (NTRS)

    Frankl, F.

    1942-01-01

    The Reynolds law of heat transfer from a wall to a turbulent stream is extended to the case of flow of a compressible gas at high speeds. The analysis is based on the modern theory of the turbulent boundary layer with laminar sublayer. The investigation is carried out for the case of a plate situated in a parallel stream. The results are obtained independently of the velocity distribution in the turbulent boundar layer.

  13. A Standard Mammography Unit - Standard 3D Ultrasound Probe Fusion Prototype: First Results.

    PubMed

    Schulz-Wendtland, Rüdiger; Jud, Sebastian M; Fasching, Peter A; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W; Emons, Julius

    2017-06-01

    The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound - the second important imaging modality in complementary breast diagnostics - without increasing examination time or requiring additional staff.

  14. PubMed Central

    Schulz-Wendtland, Rüdiger; Jud, Sebastian M.; Fasching, Peter A.; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W.; Emons, Julius

    2017-01-01

    Aim The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Materials and Methods Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. Results The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. Conclusion In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound – the second important imaging modality in complementary breast diagnostics – without increasing examination time or requiring additional staff. PMID:28713173

  15. Damage Control Plan for International Space Station Recharge Tank Assembly Composite Overwrapped Pressure Vessel

    NASA Technical Reports Server (NTRS)

    Cook, Anthony J.

    2011-01-01

    As NASA has retired the Space Shuttle Program, a new method of transporting compressed gaseous nitrogen and oxygen needed to be created for delivery of these crucial life support resources to the International Space Station (ISS). One of the methods selected by NASA includes the use of highly pressurized, unprotected Recharge Tank Assemblies (RTAs) utilizing Composite Overwrapped Pressure Vessels (COPVs). A COPV consists of a thin liner wrapped with a fiber composite and resin or epoxy. It is typically lighter weight than an all metal pressure vessel of similar volume and therefore provides a higher-efficiency means for gas storage. However COPVs are known to be susceptible to damage resulting from handling, tool drop impacts, or impacts from other objects. As a result, a comprehensive Damage Control Plan has been established to mitigate damage to the RTA COPV throughout its life cycle. The DCP is intended to evaluate and mitigate defined threats during manufacturing, shipping and handling, test, assembly level integration, shipment while pressurized, launch vehicle integration and mission operations by defining credible threats and methods for preventing potential damage while still maintaining the primary goal of resupplying ISS gas resources. A comprehensive threat assessment is performed to identify all threats posed to the COPV during the different phases of its lifecycle. The threat assessment is then used as the basis for creating a series of general inspection, surveillance and reporting requirements which apply across all phases of the COPV's life, targeted requirements only applicable to specific work phases and a series of training courses for both ground personnel and crew aboard the ISS. A particularly important area of emphasis deals with creating DCP requirements for a highly pressurized, large and unprotected RTA COPV for use during Inter Vehicular Activities (IVA) operations in the micro gravity environment while supplying pressurized gas to the ISS for crew life support.

  16. Dietary exposure to chloropropanols of secondary school students in Hong Kong.

    PubMed

    Yau, J C W; Kwong, K P; Chung, S W C; Ho, Y Y; Xiao, Y

    2008-01-01

    This paper reports levels of 3-monochloropropan-1,2-diol (3-MCPD) and 1,3-dichloro-2-propanol (1,3-DCP) in a wide range of food items and estimates their dietary exposure for secondary school students in Hong Kong. Dietary exposure to chloropropanols was estimated using local food consumption data obtained from secondary school students in 2000 and the concentrations of 3-MCPD and 1,3-DCP in food samples taken from the local market. The dietary exposure to 3-MCPD for an average secondary school student consumer was estimated to be 0.063-0.150 µg kg(-1) body weight (bw) day(-1), whilst that for the high consumer was 0.152-0.300 µg kg(-1) bw day(-1). Both estimates fell below the provisional maximum tolerable daily intake of 2 µg kg(-1) bw established by the Joint Expert Committee on Food Additives (JECFA) and amounted to less than 20% of this safety reference value. The dietary exposure to 1,3-DCP for an average secondary school student consumer was estimated to be 0.003-0.019 µg kg(-1) bw day(-1), whilst that for the high consumer was 0.009-0.040 µg kg(-1) bw day(-1). The resulting margins of exposures were of low concern for human health. It could be concluded that both the average and high secondary school student consumers were unlikely to experience major toxicological effects of 3-MCPD and 1,3-DCP.

  17. Active deformation processes of the Northern Caucasus deduced from the GPS observations

    NASA Astrophysics Data System (ADS)

    Milyukov, Vadim; Mironov, Alexey; Rogozhin, Eugeny; Steblov, Grigory; Gabsatarov, Yury

    2015-04-01

    The Northern Caucasus, as a part of the Alpine-Himalayan mobile belt, is a zone of complex tectonics associated with the interaction of the two major tectonic plates, Arabian and Eurasian. The first GPS study of the contemporary geodynamics of the Caucasus mountain system were launched in the early 1990s in the framework of the Russia-US joint project. Since 2005 observations of the modern tectonic motion of the Northern Caucasus are carried out using the continuous GPS network. This network encompasses the territory of three Northern Caucasian Republics of the Russian Federation: Karachay-Cherkessia, Kabardino-Balkaria, and North Ossetia. In the Ossetian part of the Northern Caucasus the network of GPS survey-mode sites has been deployed as well. The GPS velocities confirm weak general compression of the Northern Caucasus with at the rate of about 1-2 mm/year. This horizontal motion at the boundary of the Northern Caucasus with respect to the Eurasian plate causes the higher seismic and tectonic activity of this transition zone. This result confirms that the source of deformation of the Northern Caucasus is the sub-meridional drift of the Arabian plate towards the adjacent boundary of the Eastern European part of the Eurasian lithospheric plate. The concept of such convergence implies that the Caucasian segment of the Alpine-Himalayan mobile belt is under compression, the layers of sedimentary and volcanic rocks are folded, the basement blocks are subject to shifts in various directions, and the upper crust layers are ruptured by reverse faults and thrusts. Weak deviation of observed velocities from the pattern corresponding to homogeneous compression can also be revealed, and numerical modeling of deformations of major regional tectonic structures, such as the Main Caucasus Ridge, can explain this. The deformation tensor deduced from the velocity field also exhibits the sub-meridional direction of the major compressional axes which coincides with the direction of the relative Arabian-Eurasian plate motion. This work is partly supported by the Russian Foundation for Basic Research under Grant No 14-45-01005 and № 14-05-90411.

  18. "A" shape plate for open rigid internal fixation of mandible condyle neck fracture.

    PubMed

    Kozakiewicz, Marcin; Swiniarski, Jacek

    2014-09-01

    Reduction of the fracture is crucial for proper outcome of the treatment. The stability of reduction is closed connected to the method of its fixation. The topic of condylar fracture osteosynthesis still remains highly controversial and challenging. That is why authors decided to propose novel design of the fixating plate and the example of its application. The aim of this study was to present A-shape plate dedicated to rigid fixation of mandible condyle neck fracture. A-shape condylar plate (ACP) design is prepared of 1.0 mm thick titanium alloy (grade 5) sheet: posterior and anterior bars are reinforced by widening to 2.5 mm and anatomically curved along the compression and traction lines in ramus and condylar neck. Superior three-hole-group has triangular organization and located on the level of condylar head. The inferior extensions of the bars are equipped in three holes located at each of lower tails. Connecting bar (2.0 mm wide) connects the first hole of each lower tails closing upper part of ACP in triangular shape. The connecting bar runs along compression line of condylar neck. Holes in ACP has 2.0 mm diameter for locking or normal screws. Height of ACP is 31 mm. The proposed new type of plate was compared by finite element analysis (FEA) to nowadays manufactured 9-hole trapezoid plate as the most similar device. ACP design was evaluated by finite element analysis (FEA) and later applied in patient affected with high condylar neck fracture complicated by fracture of coronoid process. FEA revealed high strength of ACP and more stabile fixation than trapezoid plate. The result was caused by multipoint fixation at three regions of the plate and reinforced bars supported by semi-horizontal connecting bar. Clinical application of ACP was as versatile as makes possible to simultaneous fixation of high condylar neck and coronoid process fracture. Application of proposed A-shape condylar plate would be possible in all levels of neck fractures and can be use for stabilization additionally existed coronoid process fracture. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Plate convergence at the westernmost Philippine Sea Plate

    NASA Astrophysics Data System (ADS)

    Wu, Wen-Nan; Hsu, Shu-Kun; Lo, Chung-Liang; Chen, How-Wei; Ma, Kuo-Fong

    2009-03-01

    To understand the convergent characteristics of the westernmost plate boundary between the Philippine Sea Plate (PSP) and Eurasian Plate (EP), we have calculated the stress states of plate motion by focal mechanisms. Cataloged by the Harvard centroid moment tensor solutions (Harvard CMT) and the Broadband Array in Taiwan (BATS) moment tensor, 251 focal mechanisms are used to determine the azimuths of the principal stress axes. We first used all the data to derive the mean stress tensor of the study area. The inversion result shows that the stress regime has a maximum compression along the direction of azimuth N299°. This result is consistent with the general direction of the rigid plate motion between the PSP and EP in the study area. In order to understand the spatial variation of the regional stress pattern, we divided the study area into six sub-areas (blocks A to F) based on the feature of the free-air gravity anomaly. We compare the compressive directions obtained from the stress inversion with the plate motions calculated by the Euler pole and the Global Positioning System (GPS) analysis. As a result, the azimuth of the maximum stress axis, σ1, generally agrees with the directions of the theoretical plate motion and GPS velocity vectors except block C (Lanhsu region) and block F (Ilan plain region). The discrepancy of convergent direction near the Ilan plain region is probably caused by the rifting of the Okinawa Trough. The deviation of the σ1 azimuth in the Lanhsu region could be attributed to a southwestward extrusion of the Luzon Arc (LA) block between 21°N and 22°N whose northern boundary may be associated with the right-lateral NE-SW trending fault (i.e. Huatung Fault, HF) along the Taitung Canyon. Comparing the σ1 stress patterns between block C and block D, great strain energy along HF may not be completely released yet. Alternatively, the upper crust of block C may significantly have decoupled from its lower crust or uppermost mantle.

  20. The reduction of starch in finishing diets supplemented with oil does not prevent the accumulation of trans-10 18:1 in lamb meat.

    PubMed

    Costa, M; Alves, S P; Francisco, A; Almeida, J; Alfaia, C M; Martins, S V; Prates, J A M; Santos-Silva, J; Doran, O; Bessa, R J B

    2017-08-01

    The experiment was conducted to test the hypothesis that the replacement of cereal with low-starch feed ingredients in lambs' finishing diets supplemented with oils could prevent the accumulation of -10-18:1 in meat. Forty lambs were fed 1 of 4 diets supplemented with soybean oil (5.9%) and fish oil (1%) for 6 wk before slaughter. The control (CON) diet contained 43% barley, and in the other diets, barley was completely replaced by dehydrated citrus pulp (DCP), dehydrated sugar beet pulp (DBP), or soybean hulls (SH). Growth performance, feed intake, and carcass and meat quality traits were analyzed. At slaughter, LM samples were collected for gene expression evaluation, and 3 d after slaughter, LM and subcutaneous (s.c.) fat samples were collected for fatty acid analysis. None of the diets affected meat quality, but the DCP diet reduced ADG ( < 0.05) and the DCP and SH diets decreased the feed-to-gain ratio ( < 0.01). The DCP diet increased ( < 0.05) the risk of parakeratosis and the severity of the lesions. Moreover, the DBP treatment led to increased a* (redness) and b* (yellowness) in s.c. fat compared with the CON treatment ( < 0.05). The lipid content of LM did not differ ( > 0.05) with treatment and averaged 34.4 g/kg of meat. Diets had no effect ( > 0.05) on SFA, PUFA, and -MUFA sums and on the -6:-3 ratio in both LM and s.c. fat. A lower expression of fatty acid synthase (FASN) was found with the DCP treatment than with the other treatments ( < 0.001). All treatments showed a high accumulation of -10-18:1, averaging 91 mg/g fatty acid in LM and 147 mg/g fatty acid in s.c. fat. The concentration of -11-18:1 in the tissues was considerably lower than that of -10-18:1, and thus the -10-18:1:-11-18:1 ratio was above 3 with all treatments. Despite this, the SH diet clearly promoted a larger deposition of -11-18:1 and -9,-11-18:2 in tissues compared with the other treatments. () gene expression and SCD activity index in LM were reduced with the SH diet compared with the CON and DCP diets. Overall, these results clearly showed, for the first time, that low-starch/high-NDF diets are not able to prevent the establishment of -10 shifted rumen biohydrogenation pathways, evaluated by the deposition of biohydrogenation intermediates in lamb meat and fat.

  1. Hydroelastic behaviour of a structure exposed to an underwater explosion

    PubMed Central

    Colicchio, G.; Greco, M.; Brocchini, M.; Faltinsen, O. M.

    2015-01-01

    The hydroelastic interaction between an underwater explosion and an elastic plate is investigated num- erically through a domain-decomposition strategy. The three-dimensional features of the problem require a large computational effort, which is reduced through a weak coupling between a one-dimensional radial blast solver, which resolves the blast evolution far from the boundaries, and a three-dimensional compressible flow solver used where the interactions between the compression wave and the boundaries take place and the flow becomes three-dimensional. The three-dimensional flow solver at the boundaries is directly coupled with a modal structural solver that models the response of the solid boundaries like elastic plates. This enables one to simulate the fluid–structure interaction as a strong coupling, in order to capture hydroelastic effects. The method has been applied to the experimental case of Hung et al. (2005 Int. J. Impact Eng. 31, 151–168 (doi:10.1016/j.ijimpeng.2003.10.039)) with explosion and structure sufficiently far from other boundaries and successfully validated in terms of the evolution of the acceleration induced on the plate. It was also used to investigate the interaction of an underwater explosion with the bottom of a close-by ship modelled as an orthotropic plate. In the application, the acoustic phase of the fluid–structure interaction is examined, highlighting the need of the fluid–structure coupling to capture correctly the possible inception of cavitation. PMID:25512585

  2. The fracture characteristic of three collinear cracks under true triaxial compression.

    PubMed

    Liu, Jianjun; Zhu, Zheming; Wang, Bo

    2014-01-01

    The mechanical behavior of multicracks under compression has become a very important project in the field of fracture mechanics and rock mechanics. In this paper, experimental and numerical studies on the fracture property of three collinear cracks under compression were implemented. The specimens were a square concrete plate, and the cracks were made by a very thin film. The tests were conducted by using true triaxial loading device. In the numerical study, the Abaqus code was employed. The effect of crack orientation and the confining stress on cracked specimen compressive strength were investigated. The results show that the critical stresses of cracked specimens change with crack inclination angles, and, as the angle is 45°, the critical stress is the lowest; the critical stresses increase with the confining stresses.

  3. The Fracture Characteristic of Three Collinear Cracks under True Triaxial Compression

    PubMed Central

    Liu, Jianjun; Zhu, Zheming; Wang, Bo

    2014-01-01

    The mechanical behavior of multicracks under compression has become a very important project in the field of fracture mechanics and rock mechanics. In this paper, experimental and numerical studies on the fracture property of three collinear cracks under compression were implemented. The specimens were a square concrete plate, and the cracks were made by a very thin film. The tests were conducted by using true triaxial loading device. In the numerical study, the Abaqus code was employed. The effect of crack orientation and the confining stress on cracked specimen compressive strength were investigated. The results show that the critical stresses of cracked specimens change with crack inclination angles, and, as the angle is 45°, the critical stress is the lowest; the critical stresses increase with the confining stresses. PMID:24790569

  4. Biomechanical Study of the Fixation Strength of Anteromedial Plating for Humeral Shaft Fractures

    PubMed Central

    Zheng, Yin-Feng; Zhou, Jun-Lin; Wang, Xiao-Hong; Shan, Lei; Liu, Yang

    2016-01-01

    Background: Open reduction and internal fixation with plate and screws are the gold standard for the surgical treatment of humeral shaft fractures, this study was to compare the mechanical properties of anteromedial, anterolateral, and posterior plating for humeral shaft fractures. Methods: A distal third humeral shaft fracture model was constructed using fourth-generation sawbones (#3404, composite bone). A total of 24 sawbones with a distal third humeral shaft fracture was randomly divided into three Groups: A, B, and C (n = 8 in each group) for anteromedial, anterolateral, and posterior plating, respectively. All sawbones were subjected to horizontal torsional fatigue tests, horizontal torsional and axial compressive fatigue tests, four-point bending fatigue tests in anteroposterior (AP) and mediolateral (ML) directions and horizontal torsional destructive tests. Results: In the horizontal torsional fatigue tests, the mean torsional angle amplitude in Groups A, B, and C were 6.12°, 6.53°, and 6.81°. In horizontal torsional and axial compressive fatigue tests, the mean torsional angle amplitude in Groups A, B, and C were 5.66°, 5.67°, and 6.36°. The mean plate displacement amplitude was 0.05 mm, 0.08 mm, and 0.10 mm. Group A was smaller than Group C (P < 0.05). In AP four-point bending fatigue tests, the mean plate displacement amplitude was 0.16 mm, 0.13 mm, and 0.20 mm. Group B was smaller than Group C (P < 0.05). In ML four-point bending fatigue tests, the mean plate displacement amplitude were 0.16 mm, 0.19 mm, and 0.17 mm. In horizontal torsional destructive tests, the mean torsional rigidity in Groups A, B, and C was 0.82, 0.75, and 0.76 N·m/deg. The yielding torsional angle was 24.50°, 25.70°, and 23.86°. The mean yielding torque was 18.46, 18.05, and 16.83 N·m, respectively. Conclusions: Anteromedial plating was superior to anterolateral or posterior plating in all mechanical tests except in AP four-point bending fatigue tests compared to the anterolateral plating group. We can suggest that anteromedial plating is a clinically safe and effective way for humeral shaft fractures. PMID:27453236

  5. Dynamic Constitutive/Failure Models

    DTIC Science & Technology

    1988-12-01

    compressive failure--microfracture versus microplasticity . Actual traces observed in plate impact tests on ceramic targets are hardly ever as simple as the...observa- tions for microfracture and microplasticity . Unfortunately, each team of investigators has used slightly different experimental techniques and

  6. Large-deflection theory for end compression of long rectangular plates rigidly clamped along two edges

    NASA Technical Reports Server (NTRS)

    Levy, Samuel; Krupen, Philip

    1943-01-01

    The von Karman equations for flat plates are solved beyond the buckling load up to edge strains equal to eight time the buckling strain, for the extreme case of rigid clamping along the edges parallel to the load. Deflections, bending stresses, and membrane stresses are given as a function of end compressive load. The theoretical values of effective width are compared with the values derived for simple support along the edges parallel to the load. The increases in effective width due to rigid clamping drops from about 20 percent near the buckling strain to about 8 percent at an edge strain equal to eight times the buckling strain. Experimental values of effective width in the elastic range reported in NACA Technical Note No. 684 are between the theoretical curves for the extremes of simple support and rigid clamping.

  7. Recent results concerning the stability of viscoelastic shear deformable plates under compressive edge loading

    NASA Technical Reports Server (NTRS)

    Librescu, L.; Chandiramani, N. K.

    1989-01-01

    Some recent results obtained by the authors are summarized concerning the stability of transversely isotropic flat panels whose materials exhibit a viscoelastic behavior and whose edges are subjected to in-plane biaxial compressive loads. Two transversely isotropic type materials, largely used in advanced technology, are considered: (1) the pyrolytic-graphite type, used in the thermal protection of aerospace vehicles, and (2) the type corresponding to unidirectional fiber-reinforced composites. In the former case, the planes of isotropy are parallel at each point to the midplane of the plate. In the latter case, they are normal to the fiber directions. The micromechanical relations developed by Aboudi (1984, 1986, 1987) are considered in conjunction with the correspondence principle of linear viscoelastic theory in order to predict the macroscopic viscoelastic properties of a material composed of uniaxial elastic fibers embedded in a linear viscoelastic matrix.

  8. Effect of high strain rates on peak stress in a Zr-based bulk metallic glass

    NASA Astrophysics Data System (ADS)

    Sunny, George; Yuan, Fuping; Prakash, Vikas; Lewandowski, John

    2008-11-01

    The mechanical behavior of Zr41.25Ti13.75Cu12.5Ni10Be22.5 (LM-1) has been extensively characterized under quasistatic loading conditions; however, its mechanical behavior under dynamic loading conditions is currently not well understood. A Split-Hopkinson pressure bar (SHPB) and a single-stage gas gun are employed to characterize the mechanical behavior of LM-1 in the strain-rate regime of 102-105/s. The SHPB experiments are conducted with a tapered insert design to mitigate the effects of stress concentrations and preferential failure at the specimen-insert interface. The higher strain-rate plate-impact compression-and-shear experiments are conducted by impacting a thick tungsten carbide (WC) flyer plate with a sandwich sample comprising a thin bulk metallic glass specimen between two thicker WC target plates. Specimens employed in the SHPB experiments failed in the gage-section at a peak stress of approximately 1.8 GPa. Specimens in the high strain-rate plate-impact experiments exhibited a flow stress in shear of approximately 0.9 GPa, regardless of the shear strain-rate. The flow stress under the plate-impact conditions was converted to an equivalent flow stress under uniaxial compression by assuming a von Mises-like material behavior and accounting for the plane strain conditions. The results of these experiments, when compared to the previous work conducted at quasistatic loading rates, indicate that the peak stress of LM-1 is essentially strain rate independent over the strain-rate range up to 105/s.

  9. Pinhole collimator scintigraphy in differential diagnosis of metastasis, fracture, and infections of the spine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bahk, Y.W.; Kim, O.H.; Chung, S.K.

    1987-04-01

    The informational gains obtained by the use of pinhole collimator scintigraphy (PCS) have been well documented. The present study has been undertaken to prospectively investigate its efficacy in diagnosing several commonly occurring spinal diseases. Patient material consisted of metastatic cancer (39 vertebrae), compression fractures (33 vertebrae), tuberculous spondylitis (17 vertebrae), and pyogenic spondylitis (six vertebrae). PCS findings were characterized in terms of localization, appearance, and homogeneity of abnormal radionuclide accumulation. Thus, metastatic cancer manifested as diffusely or focally homogeneous accumulation within the vertebral body or as a typical short-segmental accumulation along the end-plate, whereas compression fracture manifested as characteristic board-likemore » accumulation along the entire length of end-plates. Tuberculous spondylitis, on the other hand, revealed homogeneous accumulation throughout the vertebral body, and pyogenic spondylitis revealed accumulation at the end-zone of opposing vertebral bodies giving sandwich-like appearance. The disk space at the affected level was not narrowed in the former two diseases but it was narrowed in the latter two. It was concluded that PCS may be useful in differentiating metastatic cancer, compression fracture, tuberculous spondylitis, and pyogenic spondylitis.« less

  10. The ambient stress field in the continental margin around the Korean Peninsula and Japanese islands

    NASA Astrophysics Data System (ADS)

    Lee, J.; Hong, T. K.; Chang, C.

    2016-12-01

    The ambient stress field is mainly influenced by regional tectonics. The stress field composition is crucial information for seismic hazard assessment. The Korean Peninsula, Japanese Islands and East Sea comprise the eastern margin of the Eurasian plate. The regions are surrounded by the Okhotsk, Pacific, and Philippine Sea plates. We investigate the regional stress field around the Korean Peninsula and Japanese islands using the focal mechanism solutions of regional earthquakes. Complex lateral and vertical variations of regional crustal stress fields are observed around a continental margin. The dominant compression directions are ENE-WSW around the Korean Peninsula and eastern China, E-W in the central East Sea and northern and southern Japan, NW-SE in the central Japan, and N-S around the northern Nankai trough. The horizontal compression directions are observed to be different by fault type, suggesting structure-dependent stress field distortion. The regional stress field change by depth and location, suggesting that the compression and tension stress may alternate in local region. The stress field and structures affect mutually, causing stress field distortion and reactivation of paleo-structures. These observation may be useful for understanding of local stress-field perturbation for seismic hazard mitigation of the region.

  11. Strength properties of interlocking compressed earth brick units

    NASA Astrophysics Data System (ADS)

    Saari, S.; Bakar, B. H. Abu; Surip, N. A.

    2017-10-01

    This study presents a laboratory investigation on the properties of interlocking compressed earth brick (ICEB) units. Compressive strength, which is one of the most important properties in masonry structures, is used to determine masonry performance. The compressive strength of the ICEB units was determined by applying a compressive strength test for 340 units from four types of ICEB. To analyze the strength of the ICEB units, each unit was capped by a steel plate at the top and bottom to create a flat surface, and then ICEB was loaded until failure. The average compressive strength of the corresponding ICEB units are as follows: wall brick, 19.15 N/mm2; beam brick, 16.99 N/mm2; column brick, 13.18 N/mm2; and half brick, 11.79 N/mm2. All the ICEB units had compressive strength of over 5 N/mm2, which is the minimum strength for a load-bearing brick. This study proves that ICEB units may be used as load-bearing bricks. The strength of ICEBs is equal to that of other common bricks and blocks that are currently available in the market.

  12. High precision Hugoniot measurements on statically pre-compressed fluid helium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seagle, Christopher T.; Reinhart, William D.; Lopez, Andrew J.

    Here we describe how the capability for statically pre-compressing fluid targets for Hugoniot measurements utilizing gas gun driven flyer plates has been developed. Pre-compression expands the capability for initial condition control, allowing access to thermodynamic states off the principal Hugoniot. Absolute Hugoniot measurements with an uncertainty less than 3% on density and pressure were obtained on statically pre-compressed fluid helium utilizing a two stage light gas gun. Helium is highly compressible; the locus of shock states resulting from dynamic loading of an initially compressed sample at room temperature is significantly denser than the cryogenic fluid Hugoniot even for relatively modestmore » (0.27–0.38 GPa) initial pressures. Lastly, the dynamic response of pre-compressed helium in the initial density range of 0.21–0.25 g/cm3 at ambient temperature may be described by a linear shock velocity (us) and particle velocity (u p) relationship: u s = C 0 + su p, with C 0 = 1.44 ± 0.14 km/s and s = 1.344 ± 0.025.« less

  13. High precision Hugoniot measurements on statically pre-compressed fluid helium

    DOE PAGES

    Seagle, Christopher T.; Reinhart, William D.; Lopez, Andrew J.; ...

    2016-09-27

    Here we describe how the capability for statically pre-compressing fluid targets for Hugoniot measurements utilizing gas gun driven flyer plates has been developed. Pre-compression expands the capability for initial condition control, allowing access to thermodynamic states off the principal Hugoniot. Absolute Hugoniot measurements with an uncertainty less than 3% on density and pressure were obtained on statically pre-compressed fluid helium utilizing a two stage light gas gun. Helium is highly compressible; the locus of shock states resulting from dynamic loading of an initially compressed sample at room temperature is significantly denser than the cryogenic fluid Hugoniot even for relatively modestmore » (0.27–0.38 GPa) initial pressures. Lastly, the dynamic response of pre-compressed helium in the initial density range of 0.21–0.25 g/cm3 at ambient temperature may be described by a linear shock velocity (us) and particle velocity (u p) relationship: u s = C 0 + su p, with C 0 = 1.44 ± 0.14 km/s and s = 1.344 ± 0.025.« less

  14. Double- and multi-carbapenemase-producers: the excessively armored bacilli of the current decade.

    PubMed

    Meletis, G; Chatzidimitriou, D; Malisiovas, N

    2015-08-01

    Multidrug-resistant (MDR) and extensively drug-resistant (XDR) Gram-negative nosocomial pathogens commonly carry one carbapenemase gene conferring resistance to carbapenems and other beta-lactam antibiotics. However, increasing reports show that double-carbapenemase-producing (DCP) and even multi-carbapenemase-producing (MCP) bacteria are emerging in some parts of the world, diminishing further, in some cases, the already limited treatment options. In the present review, the up-to-date reports of DCP and MCP isolates are summarized and concerns regarding their emergence are discussed.

  15. CFD Simulations of the IHF Arc-Jet Flow: Compression-Pad Separation Bolt Wedge Tests

    NASA Technical Reports Server (NTRS)

    Gokcen, Tahir; Skokova, Kristina A.

    2017-01-01

    This paper reports computational analyses in support of two wedge tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using two different wedge models, each placed in a free jet downstream of a corresponding different conical nozzle in the Ames 60-MW Interaction Heating Facility. Each panel test article included a metallic separation bolt imbedded in Orion compression-pad and heatshield materials, resulting in a circular protuberance over a flat plate. The protuberances produce complex model flowfields, containing shock-shock and shock-boundary layer interactions, and multiple augmented heating regions on the test plate. As part of the test calibration runs, surface pressure and heat flux measurements on water-cooled calibration plates integrated with the wedge models were also obtained. Surface heating distributions on the test articles as well as arc-jet test environment parameters for each test configuration are obtained through computational fluid dynamics simulations, consistent with the facility and calibration measurements. The present analysis comprises simulations of the non-equilibrium flow field in the facility nozzle, test box, and flow field over test articles, and comparisons with the measured calibration data.

  16. CFD Simulations of the IHF Arc-Jet Flow: Compression-Pad/Separation Bolt Wedge Tests

    NASA Technical Reports Server (NTRS)

    Goekcen, Tahir; Skokova, Kristina A.

    2017-01-01

    This paper reports computational analyses in support of two wedge tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using two different wedge models, each placed in a free jet downstream of a corresponding different conical nozzle in the Ames 60-MW Interaction Heating Facility. Each panel test article included a metallic separation bolt imbedded in Orion compression-pad and heatshield materials, resulting in a circular protuberance over a flat plate. The protuberances produce complex model flowfields, containing shock-shock and shock-boundary layer interactions, and multiple augmented heating regions on the test plate. As part of the test calibration runs, surface pressure and heat flux measurements on water-cooled calibration plates integrated with the wedge models were also obtained. Surface heating distributions on the test articles as well as arc-jet test environment parameters for each test configuration are obtained through computational fluid dynamics simulations, consistent with the facility and calibration measurements. The present analysis comprises simulations of the nonequilibrium flowfield in the facility nozzle, test box, and flowfield over test articles, and comparisons with the measured calibration data.

  17. Efficient 3-D finite element failure analysis of compression loaded angle-ply plates with holes

    NASA Technical Reports Server (NTRS)

    Burns, S. W.; Herakovich, C. T.; Williams, J. G.

    1987-01-01

    Finite element stress analysis and the tensor polynomial failure criterion predict that failure always initiates at the interface between layers on the hole edge for notched angle-ply laminates loaded in compression. The angular location of initial failure is a function of the fiber orientation in the laminate. The dominant stress components initiating failure are shear. It is shown that approximate symmetry can be used to reduce the computer resources required for the case of unaxial loading.

  18. Compression behavior of delaminated composite plates

    NASA Technical Reports Server (NTRS)

    Peck, Scott O.; Springer, George S.

    1989-01-01

    The response of delaminated composite plates to compressive in-plane loads was investigated. The delaminated region may be either circular or elliptical, and may be located between any two plies of the laminate. For elliptical delaminations, the axes of the ellipse may be arbitrarily oriented with respect to the applied loads. A model was developed that describes the stresses, strains, and deformation of the sublaminate created by the delamination. The mathematical model is based on a two dimensional nonlinear plate theory that includes the effects of transverse shear deformation. The model takes into account thermal and moisture induced strains, transverse pressures acting on the sublaminate, and contact between the sublaminate and plate. The solution technique used is the Ritz method. A computationally efficient computer implementation of the model was developed. The code can be used to predict the nonlinear-load-strain behavior of the sublaminate including the buckling load, postbuckling behavior, and the onset of delamination growth. The accuracy of the code was evaluated by comparing the model results to benchmark analytical solutions. A series of experiments was conducted on Fiberite T300/976 graphite/epoxy laminates bonded to an aluminum honeycomb core forming a sandwich panel. Either circles or ellipses made from Teflon film were embedded in the laminates, simulating the presence of a delamination. Each specimen was loaded in compression and the strain history of the sublaminate was recorded far into the postbuckling regime. The extent of delamination growth was evaluated by C-scan examination of each specimen. The experimental data were compared to code predictions. The code was found to describe the data with reasonable accuracy. A sensitivity study examined the relative importance of various material properties, the delamination dimensions, the contact model, the transverse pressure differential, the critical strain energy release rate, and the relative growth direction on the buckling load, the postbuckling behavior, and the growth load of the sublaminate.

  19. Successive post-Variscan stress fields in the French Massif Central and its borders (Western European plate): comparison with geodynamic data

    NASA Astrophysics Data System (ADS)

    Blés, J. L.; Bonijoly, D.; Castaing, C.; Gros, Y.

    1989-11-01

    Structural analysis and particularly microtectonic methods have made it possible to define the different stages of brittle deformation of the Massif Central basement and the surrounding sedimentary cover from the end of the Hercynian orogeny to the end of the Tertiary. During the Stephanian a compressional tectonic regime prevailed: regional faults appeared or were react vated reactivation as a result of initial N-S compression, becoming NW then E-W. These regional strike-slip faults caused local extension which led to the formation of small coal-bearing basins. This compressional regime, which marked the end of the formation of Pangea. was followed by a series of extension episodes: Permian-Triassic extension oscillating around N-S. E-W to NW-SE extension in the Early and Middle Jurassic and finally N-S to NE-SW extension in the Late Jurassic to Cretaceous. The normal faults formed during these episodes strongly influenced the distribution of emerging continents and sedimentary basins. From the Campanian (75 Ma) to the Present, the convergence of Africa and Eurasia involved the distribut on of stresses in the West European plate. Several tectonic episodes are distinguished in the Massif Central. During the Eocene approximately N-S compression predominated. General E-W extension in the Late Eocene-Oligocene resulted in grabens with general northerly strike, mainly in the centre of the Massif Central and on its east and southeast borders. Lastly, compression, varying from NW-SE to E-W, in the north and south of the Massif Central, prevailed during the Alpine orogenic phase at the end of the Miocene. These successive stages of brittle deformation are interpreted in the context of the evolution of the West European plate and its displacement in relation to the African plate. The correspondences between the major geodynamic periods and the distribution of stresses over the West European continent are noted as well as the problems which remair to be resolved.

  20. Seismogenic patterns in the Taiwan region: insights from source parameter inversion of BATS data

    NASA Astrophysics Data System (ADS)

    Kao, Honn; Jian, Pei-Ru

    2001-04-01

    We systematically invert source parameters of 96 earthquakes that occurred in the Taiwan region between July 1995 and June 1998, using waveforms recorded by the newly established Broadband Array in Taiwan for Seismology (BATS). The results are utilized to delineate the seismogenic patterns associated with the regional tectonic processes between the Eurasia and Philippine Sea plates. In general, high seismicity is observed at five locations, including the Nan-ao basin (∼24°N, ∼122.4°E), near the Hualien area (∼24.2°N, ∼121.7°E), east of the Longitudinal Valley and within the Philippine Sea plate, the forearc region to the west of Lanshu, and the Okinawa trough. Events with focal depths less than 25 km scatter across a wide region from the Taiwan Strait to the Ryukyu and Luzon arcs, whereas events between 25 and 50 km concentrate offshore east of Taiwan. Most earthquakes that occurred beneath the Nan-ao basin are consistent with the northward subduction of the Philippine Sea plate along the plate interface. Events offshore east of the Longitudinal Valley and within the Philippine Sea plate are dominated by a compressional regime along the NW/NWW directions, whereas the Lanshu-Lutao forearc is characterized by E-W compression. Normal faults showing N-S extension are observed in the Okinawa trough where we observed a successive rotation of T-axes from N-S to NW-SE as the epicenters approach Taiwan, indicating a possible interaction between the extensional and compressional strain regimes there. Most events between 50 and 65 km depth within the subducted Philippine Sea plate beneath Ryukyu are in downdip extension with lateral compression approximately parallel to the strike of the slab. The depth where the state of strain switches from downdip extension to downdip compression is constrained at 110-125 km for the southernmost Ryukyu slab. Based on our results, we propose that the subducted Philippine Sea plate beneath NE Taiwan plays a significant role in the overall orogenic process of Taiwan. The lithospheric collision in Taiwan should consist of two major components: one is the well-recognized ;arc-continent collision; that dominates the central and southern Taiwan and another the ;slab-continent collision; that reigns in northern Taiwan. A cluster of earthquakes near Hualien suggests that an incipient west- or northwestward subduction of the Philippine Sea plate is currently taking place there. Alternatively, they can be interpreted to suggest that the steeply east-dipping Longitudinal Valley fault may have transformed, near Hualien, into a diffuse thrust zone, which eventually connects itself to the plate interplate beneath the southernmost Ryukyu arc. Earthquakes beneath Taiwan and the Taiwan Strait are compatible with the overall collision convergence and lateral extrusion. Nonetheless, the lateral extrusion is probably only a secondary feature in the tectonic processes of Taiwan.

  1. Effects of Perforation on Rigid PU Foam Plates: Acoustic and Mechanical Properties

    PubMed Central

    Lin, Jia-Horng; Chuang, Yu-Chun; Li, Ting-Ting; Huang, Chen-Hung; Huang, Chien-Lin; Chen, Yueh-Sheng; Lou, Ching-Wen

    2016-01-01

    Factories today are equipped with diverse mechanical equipment in response to rapid technological and industrial developments. Industrial areas located near residential neighborhoods cause massive environmental problems. In particular, noise pollution results in physical and psychological discomfort, and is a seen as invisible and inevitable problem. Thus, noise reduction is a critical and urgent matter. In this study, rigid polyurethane (PU) foam plates undergo perforation using a tapping machine. The mechanical and acoustic properties of these perforated plates as related to perforation rate and perforation depth are evaluated in terms of compression strength, drop-weight impact strength, and sound absorption coefficient. Experimental results indicate that applying the perforation process endows the rigid PU foaming plates with greater load absorption and better sound absorption at medium and high frequencies. PMID:28774119

  2. Effects of Perforation on Rigid PU Foam Plates: Acoustic and Mechanical Properties.

    PubMed

    Lin, Jia-Horng; Chuang, Yu-Chun; Li, Ting-Ting; Huang, Chen-Hung; Huang, Chien-Lin; Chen, Yueh-Sheng; Lou, Ching-Wen

    2016-12-09

    Factories today are equipped with diverse mechanical equipment in response to rapid technological and industrial developments. Industrial areas located near residential neighborhoods cause massive environmental problems. In particular, noise pollution results in physical and psychological discomfort, and is a seen as invisible and inevitable problem. Thus, noise reduction is a critical and urgent matter. In this study, rigid polyurethane (PU) foam plates undergo perforation using a tapping machine. The mechanical and acoustic properties of these perforated plates as related to perforation rate and perforation depth are evaluated in terms of compression strength, drop-weight impact strength, and sound absorption coefficient. Experimental results indicate that applying the perforation process endows the rigid PU foaming plates with greater load absorption and better sound absorption at medium and high frequencies.

  3. Microstructure and mechanical properties of 2.5 vol. % TiBw/Ti6Al4V composites plates fabricated by hot-hydrostatic canned extrusion

    NASA Astrophysics Data System (ADS)

    Zhang, Wencong; Zhang, Lingjia; Feng, Yangju; Cui, Guorong; Chen, Wenzhen

    2018-04-01

    Plates of 2.5 vol. % TiB whisker-reinforced Ti6Al4V titanium matrix composites (TiBw/Ti64) with network structure were successfully fabricated by hot-hydrostatic extrusion with steel cup at 1100 °C. The dimensions of plates were about 150mm in length, 27mm in width and 2mm in thickness. After extrusion, the original equiaxed-network structure formed by TiB whiskers still existed, but was compressed in cross-section and stretched in longitudinal section and then the TiB whiskers were directional distribution along the extrusion direction. Furthermore, the mechanical properties results showed that the strength, hardness and ductility of the plates were significantly improved compared to as-sintered composites.

  4. Force characteristics of a modular squeeze mode magneto-rheological element

    NASA Astrophysics Data System (ADS)

    Craft, Michael J.; Ahmadian, Mehdi; Farjoud, Alireza; Burke, William C. T.; Nagode, Clement

    2010-04-01

    While few publications exist on the behavior of Magneto-Rheological (MR) fluid in squeeze mode, devices using squeeze mode may take advantage of the very large range of adjustment that squeeze mode offers. Based on results obtained through modeling and testing MR fluid in a squeeze mode rheometer, a novel compression-adjustable element has been fabricated and tested, which utilizes MR fluid in squeeze mode. While shear and valve modes have been used exclusively for MR fluid damping applications, recent modeling and testing with MR fluid has revealed that much larger adjustment ranges are achievable in squeeze mode. Utilizing squeeze mode, a compression element, or MR Pouch, was developed consisting of a flexible cylindrical membrane with each end fastened to a steel endplate (pole plates). The silicone rubber pouch material was molded in the required shape for use in the squeeze mode rheometer. This flexible membrane allows for the complete self-containment of MR fluid and because the pouch compensates for volume changes, there is no need for dynamic seals and associated surface finish treatments on the steel components. An electromagnet incorporated in the rheometer passes an adjustable magnetic field axially through the pole plates and MR fluid. Test results show the device was capable of varying the compression force from less than 8lbs to greater than 1000lbs when the pole plates were 0.050" apart. Simulations were compared against test data with good correlation. Possible applications of this technology include primary suspension components, auxiliary suspension bump stops, and other vibration isolation components, as MR Pouches are scalable depending on the application and force requirements.

  5. Optimisation of composite bone plates for ulnar transverse fractures.

    PubMed

    Chakladar, N D; Harper, L T; Parsons, A J

    2016-04-01

    Metallic bone plates are commonly used for arm bone fractures where conservative treatment (casts) cannot provide adequate support and compression at the fracture site. These plates, made of stainless steel or titanium alloys, tend to shield stress transfer at the fracture site and delay the bone healing rate. This study investigates the feasibility of adopting advanced composite materials to overcome stress shielding effects by optimising the geometry and mechanical properties of the plate to match more closely to the bone. An ulnar transverse fracture is characterised and finite element techniques are employed to investigate the feasibility of a composite-plated fractured bone construct over a stainless steel equivalent. Numerical models of intact and fractured bones are analysed and the mechanical behaviour is found to agree with experimental data. The mechanical properties are tailored to produce an optimised composite plate, offering a 25% reduction in length and a 70% reduction in mass. The optimised design may help to reduce stress shielding and increase bone healing rates. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. A simple nonlinear element model

    NASA Astrophysics Data System (ADS)

    Mikhailov, S. G.; Rudenko, O. V.

    2017-05-01

    We study experimentally the behavior of a nonlinear element, a light plate pressed to the opening in the cavity of an acoustic resonator. Measurements of field oscillations inside and outside the cavity have shown that for large amplitudes, they become essentially anharmonic. The time dependences of displacement of the plate with increasing amplitude of the exciting voltage demonstrates a gradual change in the shape of vibrations from harmonic to half-period oscillation. A constant component appears in the cavity: rarefaction or outflow of the medium through the orifice. We construct a theory for nonlinear oscillations of a plate taking into account its different elastic reactions to compression and rarefaction with allowance for monopole radiation by the small-wave-size plate or radiation of a plane wave by the plate. We calculate the amplitudes of the harmonics and solve the problem of low-frequency stationary noise acting on the plate. We obtain expressions for the correlation function and mean power at the output given a normal random process at the input.

  7. Tensile behaviors of three-dimensionally free-formable titanium mesh plates for bone graft applications

    NASA Astrophysics Data System (ADS)

    He, Jianmei

    2017-11-01

    Present metal artificial bones for bone grafts have the problems like too heavy and excessive elastic modulus compared with natural bones. In this study, three-dimensionally (3D) free-formable titanium mesh plates for bone graft applications was introduced to improve these problems. Fundamental mesh shapes and patterns were designed under different base shapes and design parameters through three dimensional CAD tools from higher flexibility and strength points of view. Based on the designed mesh shape and patterns, sample specimens of titanium mesh plates with different base shapes and design variables were manufactured through laser processing. Tensile properties of the sample titanium mesh plates like volume density, tensile elastic modulus were experimentally and analytically evaluated. Experimental results showed that such titanium mesh plates had much higher flexibility and their mechanical properties could be controlled to close to the natural bones. More details on the mechanical properties of titanium mesh plates including compression, bending, torsion and durability will be carried out in future study.

  8. Assessment of carbon fibre composite fracture fixation plate using finite element analysis.

    PubMed

    Saidpour, Seyed H

    2006-07-01

    In the internal fixation of fractured bone by means of bone-plates fastened to the bone on its tensile surface, an on-going concern has been the excessive stress shielding of the bone by the excessively-stiff stainless-steel plate. The compressive stress shielding at the fracture-interface immediately after fracture-fixation delays callus formation and bone healing. Likewise, the tensile stress shielding in the layer of bone underneath the plate can cause osteoporosis and decrease in tensile strength of this layer. In this study a novel forearm internal fracture fixation plate made from short carbon fibre reinforced plastic (CFRP) was used in an attempt to address the problem. Accordingly, it has been possible to analyse the stress distribution in the composite plates using finite-element modelling. A three-dimensional, quarter-symmetric finite element model was generated for the plate system. The stress state in the underlying bone was examined for several loading conditions. Based on the analytical results the composite plate system is likely to reduce stress-shielding effects at the fracture site when subjected to bending and torsional loads. The design of the plate was further optimised by reducing the width around the innermost holes.

  9. Functional outcome of displaced intra-articular calcaneal fractures: a comparison between open reduction/internal fixation and a minimally invasive approach featured an anatomical plate and compression bolts.

    PubMed

    Wu, Zhanpo; Su, Yanling; Chen, Wei; Zhang, Qi; Liu, Yueju; Li, Ming; Wang, Haili; Zhang, Yingze

    2012-09-01

    The purpose of this study is to assess the clinical results of a minimally invasive treatment featured the concept of internal compression, including an anatomic plate and multiple compression bolts compared with open reduction and internal fixation for displaced intra-articular calcaneal fractures (DIACFs). We retrospectively analyzed 329 patients (383 feet) who were identified from trauma inpatient database in our hospital for DIACFs from January 2004 to December 2009. Of them, 148 patients (170 feet) were treated with open reduction and internal fixation (OR group), which involved using a traditional L-shaped extended lateral approach, and fractures were fixed by plate and screws from January 2004 to December 2006; 181 patients (213 feet) were treated with a minimally invasive approach featured the concept of calcaneal internal compression (CIC group), which was achieved by an anatomic plate and multiple compression bolts through a small lateral incision from January 2007 to December 2009. Postoperative complications were recorded. During follow-up, pain and functional outcome were evaluated with the American Orthopaedic Foot and Ankle Society (AOFAS) scores and compared between the two groups. Subsequent subtalar arthrodesis and early implant removal were performed when indicated. Routine hardware removal was scheduled for all patients at 1-year follow-up. There were no significant differences in sex, age, and fracture classification (Sanders classification) between the two groups. Wound healing complications were 4 of 213 (1.88%) in CIC group and 20 of 170 (11.76%) in OR group. Subtalar arthrodesis had to be performed in one case in OR group. Four cases in CIC group and four cases in OR group had the hardware removed earlier due to complications. The average time after surgery to start weight-bearing exercise is 5.64 weeks in CIC group and 9.38 weeks in OR group (p < 0.001). The mean AOFAS score is higher in CIC group than in OR group, although the difference is not statistically significant (87.53 vs. 84.95; p = 0.191). The overall results according to the AOFAS scoring system were good or excellent in 185 of 213 (86.85%) in CIC group and 144 of 170 (84.71%) in OR group. The subjective portion of the AOFAS survey answered by patients showed statistically significant difference in activity limitation and walking surface score (7.31 vs. 7.02 and 3.72 vs. 3.42; p < 0.05) but not in pain and walking distance between the two groups (32.72 vs. 32.29 and 4.37 vs. 4.42; p > 0.05). The study results suggest that this minimally invasive approach featured the concept of the calcaneal internal compression can achieve functional outcome as good as, if not better than the open techniques. It is proved to be an effective alternative treatment for DIACFs. Therapeutic study, level IV.

  10. [APPLICATION OF BUTTERFLY SHAPED LOCKING COMPRESSION PLATE IN COMPLEX DISTAL RADIUS FRACTURES].

    PubMed

    Jiang, Zongyuan; Ma, Tao; Xia, Jiang; Hu, Caizhi; Xu, Lei

    2014-06-01

    To investigate the effectiveness of butterfly shaped locking compression plate for the treatment of complex distal radius fractures. Between June 2011 and January 2013, 20 cases of complex distal radius fractures were treated with butterfly shaped locking compression plate fixation. There were 11 males and 9 females with an average age of 54 years (range, 25-75 years). Injury was caused by falling in 10 cases, by traffic accident in 7 cases, and by falling from height in 3 cases. All of fractures were closed. According to AO classification system, there were 8 cases of type C1, 8 cases of type C2, and 4 cases of type C3. Of them, 9 cases had radial styloid process fracture, 4 cases had sigmoid notch fracture, and 7 cases had both radial styloid process fracture and sigmoid notch fracture. The mean interval between injury and operation was 5.2 days (range, 3-15 days). All incisions healed by first intention; no complications of infection and necrosis occurred. All cases were followed up 14 months on average (range, 10-22 months). All factures healed after 9.3 weeks on average (range, 6-11 weeks). No complications such as displacement of fracture, joint surface subsidence, shortening of the radius, and carpal tunnel syndrome were found during follow-up. At last follow-up, the mean palmar tilt angle was 10.2° (range, 7-15°), and the mean ulnar deviation angle was 21.8° (range, 17-24°). The mean range of motion of the wrist was 45.3° (range, 35-68°) in dorsal extension, 53.5° (range, 40-78°) in palmar flexion, 19.8° (range, 12-27°) in radial inclination, 26.6° (range, 18-31°) in ulnar inclination, 70.2° (range, 45-90°) in pronation, and 68.4° (range, 25-88°) in supination. According to the Dienst scoring system, the results were excellent in 8 cases, good in 10 cases, and fair in 2 cases, and the excellent and good rate was 90%. Treatment of complex distal radius fractures with butterfly shaped locking compression plate can reconstruct normal anatomic structures, especially for radial styloid process and sigmoid notch fractures, and it can get good functional recovery of the wrist and the distal radioulnar joint.

  11. The compressive failure of graphite/epoxy plates with circular holes

    NASA Technical Reports Server (NTRS)

    Knauss, J. F.; Starnes, J. H., Jr.; Henneke, E. G., II

    1978-01-01

    The behavior of fiber reinforced composite plates containing a circular cutout was characterized in terms of geometry (thickness, width, hole diameter), and material properties (bending/extensional stiffness). Results were incorporated in a data base for use by designers in determining the ultimate strength of such a structure. Two thicknesses, 24 plies and 48 plies were chosen to differentiate between buckling and strength failures due to the presence of a cutout. Consistent post-buckling strength was exhibited by both laminate configurations.

  12. Compressive behavior of laminated neoprene bridge bearing pads under thermal aging condition

    NASA Astrophysics Data System (ADS)

    Jun, Xie; Zhang, Yannian; Shan, Chunhong

    2017-10-01

    The present study was conducted to obtain a better understanding of the variation rule of mechanical properties of laminated neoprene bridge bearing pads under thermal aging condition using compression tests. A total of 5 specimens were processed in a high-temperature chamber. After that, the specimens were tested subjected to axial load. The parameter mainly considered time of thermal aging processing for specimens. The results of compression tests show that the specimens after thermal aging processing are more probably brittle failure than the standard specimen. Moreover, the exposure of steel plate, cracks and other failure phenomena are more serious than the standard specimen. The compressive capacity, ultimate compressive strength, compressive elastic modulus of the laminated neoprene bridge bearing pads decreased dramatically with the increasing in the aging time of thermal aging processing. The attenuation trends of ultimate compressive strength, compressive elastic modulus of laminated neoprene bridge bearing pads under thermal aging condition accord with power function. The attenuation models are acquired by regressing data of experiment with the least square method. The attenuation models conform to reality well which shows that this model is applicable and has vast prospect in assessing the performance of laminated neoprene bridge bearing pads under thermal aging condition.

  13. Simultaneous Analysis of 3-MCPD and 1,3-DCP in Asian Style Sauces Using QuEChERS Extraction and Gas Chromatography-Triple Quadrupole Mass Spectrometry.

    PubMed

    Genualdi, Susan; Nyman, Patricia; DeJager, Lowri

    2017-02-01

    Acid hydrolyzed vegetable protein (aHVP) is used for flavoring a wide variety of foods and also in the production of nonfermented soy sauce. During the production of aHVP, chloropropanols including 3-monochloropropane-1,2-diol (3-MCPD) and 1,3 dichloropropane-2-ol (1,3-DCP) can be formed through the reaction of the hydrochloric acid catalyst and residual fat and the reaction of 3-MCPD with acetic acid, respectively. 3-MCPD is a carcinogen, and 1,3-DCP has been classified as a genotoxic carcinogen. The European Union (EU) has set a maximum concentration of 0.02 mg/kg of 3-MCPD in aHVP, and the Food and Drug Administration (FDA) set a guidance limit of 1 mg/kg of 3-MCPD in aHVP. 1,3-DCP is not an approved food additive, and the Joint FAO/WHO Expert Committee on Food Additives (JEFCA) has set a limit at 0.005 mg/kg, which is close to the estimated method detection limit. Currently there are few analytical methods for the simultaneous determination of 3-MCPD and 1,3-DCP without derivatization due to differences in their physical chemical properties and reactivity. A new method was developed using QuEChERS (quick, easy, cheap, effective, rugged, and safe) with direct analysis of the extract without derivatization using gas chromatography-triple quadrupole mass spectrometry (GC-QQQ). Additionally, a market sampling of 60 soy sauce samples was performed in 2015 to determine if concentrations have changed since the FDA limit was set in 2008. The sampling results were compared between the new QuEChERS method and a method using phenylboronic acid (PBA) as a derivatizing agent for 3-MCPD analysis. The concentrations of 3-MCPD detected in soy sauce samples collected in 2015 (

  14. Simultaneous Analysis of 3-MCPD and 1,3-DCP in Asian Style Sauces Using QuEChERS Extraction and Gas Chromatography–Triple Quadrupole Mass Spectrometry

    PubMed Central

    Genualdi, Susan; Nyman, Patricia; DeJager, Lowri

    2017-01-01

    Acid hydrolyzed vegetable protein (aHVP) is used for flavoring a wide variety of foods and also in the production of nonfermented soy sauce. During the production of aHVP, chloropropanols including 3-monochloropropane-1,2-diol (3-MCPD) and 1,3 dichloropropane-2-ol (1,3-DCP) can be formed through the reaction of the hydrochloric acid catalyst and residual fat and the reaction of 3-MCPD with acetic acid, respectively. 3-MCPD is a carcinogen, and 1,3-DCP has been classified as a genotoxic carcinogen. The European Union (EU) has set a maximum concentration of 0.02 mg/kg of 3-MCPD in aHVP, and the Food and Drug Administration (FDA) set a guidance limit of 1 mg/kg of 3-MCPD in aHVP. 1,3-DCP is not an approved food additive, and the Joint FAO/WHO Expert Committee on Food Additives (JEFCA) has set a limit at 0.005 mg/kg, which is close to the estimated method detection limit. Currently there are few analytical methods for the simultaneous determination of 3-MCPD and 1,3-DCP without derivatization due to differences in their physical chemical properties and reactivity. A new method was developed using QuEChERS (quick, easy, cheap, effective, rugged, and safe) with direct analysis of the extract without derivatization using gas chromatography–triple quadrupole mass spectrometry (GC-QQQ). Additionally, a market sampling of 60 soy sauce samples was performed in 2015 to determine if concentrations have changed since the FDA limit was set in 2008. The sampling results were compared between the new QuEChERS method and a method using phenylboronic acid (PBA) as a derivatizing agent for 3-MCPD analysis. The concentrations of 3-MCPD detected in soy sauce samples collected in 2015 (

  15. Error quantification of osteometric data in forensic anthropology.

    PubMed

    Langley, Natalie R; Meadows Jantz, Lee; McNulty, Shauna; Maijanen, Heli; Ousley, Stephen D; Jantz, Richard L

    2018-06-01

    This study evaluates the reliability of osteometric data commonly used in forensic case analyses, with specific reference to the measurements in Data Collection Procedures 2.0 (DCP 2.0). Four observers took a set of 99 measurements four times on a sample of 50 skeletons (each measurement was taken 200 times by each observer). Two-way mixed ANOVAs and repeated measures ANOVAs with pairwise comparisons were used to examine interobserver (between-subjects) and intraobserver (within-subjects) variability. Relative technical error of measurement (TEM) was calculated for measurements with significant ANOVA results to examine the error among a single observer repeating a measurement multiple times (e.g. repeatability or intraobserver error), as well as the variability between multiple observers (interobserver error). Two general trends emerged from these analyses: (1) maximum lengths and breadths have the lowest error across the board (TEM<0.5), and (2) maximum and minimum diameters at midshaft are more reliable than their positionally-dependent counterparts (i.e. sagittal, vertical, transverse, dorso-volar). Therefore, maxima and minima are specified for all midshaft measurements in DCP 2.0. Twenty-two measurements were flagged for excessive variability (either interobserver, intraobserver, or both); 15 of these measurements were part of the standard set of measurements in Data Collection Procedures for Forensic Skeletal Material, 3rd edition. Each measurement was examined carefully to determine the likely source of the error (e.g. data input, instrumentation, observer's method, or measurement definition). For several measurements (e.g. anterior sacral breadth, distal epiphyseal breadth of the tibia) only one observer differed significantly from the remaining observers, indicating a likely problem with the measurement definition as interpreted by that observer; these definitions were clarified in DCP 2.0 to eliminate this confusion. Other measurements were taken from landmarks that are difficult to locate consistently (e.g. pubis length, ischium length); these measurements were omitted from DCP 2.0. This manual is available for free download online (https://fac.utk.edu/wp-content/uploads/2016/03/DCP20_webversion.pdf), along with an accompanying instructional video (https://www.youtube.com/watch?v=BtkLFl3vim4). Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Osteochondroma of the Scapula with Accessory Nerve (XI) Compression.

    PubMed

    Beauchamp-Chalifour, Philippe; Pelet, Stéphane

    2018-01-01

    Osteochondroma is the most common benign bone tumor and is characterized as a cartilage-capped bony stalk. This lesion usually develops from the growth plate of long bones. Most osteochondromas are asymptomatic. Neurovascular compressions or cosmetic issues can occur in specific locations. Malignant transformation is extremely rare, and MRI can help evaluate these lesions. Symptomatic mass and malignancy features are the main surgical indications. Uncommonly, an osteochondroma can develop from flat bones. We present the case of a 25-year-old patient with a right scapula osteochondroma causing an accessory nerve compression. The mass was surgically removed, and the diagnosis was confirmed. The patient fully recovered at the latest 3-year follow-up visit.

  17. Fluxes of 238U decay series radionuclides in a dicalcium phosphate industrial plant.

    PubMed

    Casacuberta, N; Masqué, P; Garcia-Orellana, J

    2011-06-15

    The production of dicalcium phosphate (DCP) is part of the phosphate industry, which has been recently included in the positive list of the NORM industries defined in the revised version of the EU-BSS (Euratom 29/96). The objective of the present work is to study specific concentrations and fluxes of (238,234)U, (230)Th, (226)Ra, (210)Pb and (210)Po at the different stages of the DCP production. Results showed highest activities of (238)U and (210)Pb were found in DCP (1500-2000 Bq kg(-1)); (230)Th and (210)Po were released together with the sludges (1600-2000 Bq kg(-1)) and (226)Ra presented particularly high activities in water (48 × 10(3) Bq m(-3)) and in the reactor scales (115 × 10(3) Bq kg(-1)). Fluxes of radionuclides showed that (238)U outflows were equally distributed between sludges (16 × 10(3) kBq h(-1)) and dicalcium phosphate (20 × 10(3) kBq h(-1)); (230)Th and (210)Po were almost entirely released in the sludges (30 × 10(3)kBq h(-1)) and the greatest (210)Pb outflow was the DCP current (25 × 10(3) kBq h(-1)). (226)Ra was mainly discharged through the water effluent (12 × 10(3) kBq h(-1)). This work highlights the importance of studying the industrial processes involving NORM, as minor changes in the production steps lead to different radionuclide distribution in the process. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Development of form stable Poly(methyl methacrylate) (PMMA) coated thermal phase change material for solar water heater applications

    NASA Astrophysics Data System (ADS)

    Munusamy, Y.; Shanmugam, S.; Shi-Ying, Kee

    2018-04-01

    Phase change material (PCM) is one of the most popular and widely used thermal energy storage material in solar water heater because it able to absorb and release a large amount of latent heat during a phase change process over a narrow temperature range. However the practical application of PCM is limited by two major issues; 1) leakage which leads to material loss and corrosion of tank and 2) large volume change during phase change process which cause pressure build up in the tank. In this work, form-stable PCM was prepared by coating myristic acid with Poly(methyl methacrylate) (PMMA) to prevent leakage of PCM. PMMA was mixed with different weight percentage (0.1, 0.2, 0.3, 0.4 and 0.5 wt%) of dicumyl peroxide (DCP). The purpose of adding DCP to PMMA is to crosslink the polymer and to increase the mechanical strength of PMMA to hold the myristic acid content inside the coating during the phase change process. Leakage test results showed that PMMA mixed with 0.1% DCP exhibit 0% leakage. This result is further supported by Field Emission Scanning Electron Microscopy (FESEM) images and Fourier transform infrared spectroscopy (FTIR) analysis results, where a compact and uniform coating without cracks were formed for PCM coated with PMMA with 0.1% DCP. Differential scanning calorimetry (DSC) results shows that the melting point of form-stable PCM is 55°C, freezing point is 50°C, the latent heat of melting and freezing is 67.59 J/g.

  19. Drosophila caspases involved in developmentally regulated programmed cell death of peptidergic neurons during early metamorphosis.

    PubMed

    Lee, Gyunghee; Wang, Zixing; Sehgal, Ritika; Chen, Chun-Hong; Kikuno, Keiko; Hay, Bruce; Park, Jae H

    2011-01-01

    A great number of obsolete larval neurons in the Drosophila central nervous system are eliminated by developmentally programmed cell death (PCD) during early metamorphosis. To elucidate the mechanisms of neuronal PCD occurring during this period, we undertook genetic dissection of seven currently known Drosophila caspases in the PCD of a group of interneurons (vCrz) that produce corazonin (Crz) neuropeptide in the ventral nerve cord. The molecular death program in the vCrz neurons initiates within 1 hour after pupariation, as demonstrated by the cytological signs of cell death and caspase activation. PCD was significantly suppressed in dronc-null mutants, but not in null mutants of either dredd or strica. A double mutation lacking both dronc and strica impaired PCD phenotype more severely than did a dronc mutation alone, but comparably to a triple dredd/strica/dronc mutation, indicating that dronc is a main initiator caspase, while strica plays a minor role that overlaps with dronc's. As for effector caspases, vCrz PCD requires both ice and dcp-1 functions, as they work cooperatively for a timely removal of the vCrz neurons. Interestingly, the activation of the Ice and Dcp-1 is not solely dependent on Dronc and Strica, implying an alternative pathway to activate the effectors. Two remaining effector caspase genes, decay and damm, found no apparent functions in the neuronal PCD, at least during early metamorphosis. Overall, our work revealed that vCrz PCD utilizes dronc, strica, dcp-1, and ice wherein the activation of Ice and Dcp-1 requires a novel pathway in addition to the initiator caspases.

  20. Novel rubbers from cationic copolymerization of soybean oils and dicyclopentadiene. 1. Synthesis and characterization.

    PubMed

    Andjelkovic, Dejan D; Larock, Richard C

    2006-03-01

    Novel thermosetting copolymers, ranging from tough and ductile to very soft rubbers, have been prepared by the cationic copolymerization of regular (SOY) and 100% conjugated soybean oils (C(100)SOY) with dicyclopentadiene (DCP) catalyzed by Norway fish oil (NFO)-modified and SOY- and C(100)SOY-diluted boron trifluoride diethyl etherate (BFE). The gelation time of the reactions varies from 4 to 991 min at 110 degrees C. The yields of the bulk copolymers are essentially quantitative, while the yields of the cross-linked copolymers remaining after Soxhlet extraction with methylene chloride range from 69% to 88%, depending on the monomer stoichiometry and the catalyst used. (1)H NMR spectroscopy and Soxhlet extraction data indicate that these copolymers consist of a cross-linked soybean oil-DCP network plasticized by certain amounts of methylene chloride-soluble linear or less cross-linked soybean oil-DCP copolymers, unreacted oil, and some low molecular weight hydrolyzed oil. The molecular weights of these soluble fractions are in the range from 400 to 10,000 g/mol based on polystyrene standards. The bulk copolymers have glass transition temperatures ranging from -22.6 to 56.6 degrees C, while their tan delta peak values range from 0.7 to 1.2. Thermogravimetric analysis (TGA) indicates that these soybean oil-DCP copolymers are thermally stable below 200 degrees C, with 10% and 50% weight loss temperatures ranging from 280 to 372 degrees C and 470-554 degrees C, respectively. These properties suggest that these biobased thermosets may prove useful alternatives to current petroleum-based plastics and find widespread utility.

Top