NASA Technical Reports Server (NTRS)
Tserng, Hua-Quen; Ketterson, Andrew; Saunier, Paul; McCarty, Larry; Davis, Steve
1998-01-01
The design, fabrication, and performance of K-band high-efficiency, linear power pHEMT amplifiers implemented in Embedded Transmission Line (ETL) MMIC configuration with unthinned GaAs substrate and topside grounding are reported. A three-stage amplifier achieved a power-added efficiency of 40.5% with 264 mW output at 20.2 GHz. The linear gain is 28.5 dB with 1-dB gain compression output power of 200 mW and 31% power-added efficiency. The carrier-to-third-order intermodulation ratio is approx. 20 dBc at the 1-dB compression point. A RF functional yield of more than 90% has been achieved.
S-band low noise amplifier using 1 μm InGaAs/InAlAs/InP pHEMT
NASA Astrophysics Data System (ADS)
Hamaizia, Z.; Sengouga, N.; Yagoub, M. C. E.; Missous, M.
2012-02-01
This paper discusses the design of a wideband low noise amplifier (LNA) in which specific architecture decisions were made in consideration of system-on-chip implementation for radio-astronomy applications. The LNA design is based on a novel ultra-low noise InGaAs/InAlAs/InP pHEMT Linear and non-linear modelling of this pHEMT has been used to design an LNA operating from 2 to 4 GHz. A common-drain in cascade with a common source inductive degeneration, broadband LNA topology is proposed for wideband applications. The proposed configuration achieved a maximum gain of 27 dB and a noise figure of 0.3 dB with a good input and output return loss (S11 < -10 dB, S22 < -11 dB). This LNA exhibits an input 1-dB compression point of -18 dBm, a third order input intercept point of 0 dBm and consumes 85 mW of power from a 1.8 V supply.
Design and fabrication of pHEMT MMIC switches for IEEE 802.11.a/b/g WLAN applications
NASA Astrophysics Data System (ADS)
Mun, Jae Kyoung; Ji, Hong Gu; Ahn, Hyokyun; Kim, Haecheon; Park, Chong-Ook
2005-08-01
In this paper, we propose a channel structure for a promising switch pHEMT with excellent isolation characteristics based on the distribution of electric field intensity beneath the Schottky contact in the transistor. Using the proposed device channel structure, SPST and SPDT switches were designed and fabricated, applicable to 2.4 GHz and 5.8 GHz WLAN systems. We discuss the relationship between dc characteristics and switch parameters in this paper in detail. The developed SPST switch exhibits a low insertion loss of 0.26 dB and a high isolation of 34.3 dB with a control voltage of 0 V/-3 V at 5.8 GHz. The SPDT also shows a good performance of 0.85 dB insertion loss and 31.5 dB isolation under the same conditions. The measured power-handling capability at 2.4 GHz reveals that the SPDT has an output power of 27 dBm at the 1 dB compression point and a third-order intercept point of more than 46 dBm.
Vitee, Nandini; Ramiah, Harikrishnan; Chong, Wei-Keat; Tan, Gim-Heng; Kanesan, Jeevan; Reza, Ahmed Wasif
2014-01-01
A low-power wideband mixer is designed and implemented in 0.13 µm standard CMOS technology based on resistive feedback current-reuse (RFCR) configuration for the application of cognitive radio receiver. The proposed RFCR architecture incorporates an inductive peaking technique to compensate for gain roll-off at high frequency while enhancing the bandwidth. A complementary current-reuse technique is used between transconductance and IF stages to boost the conversion gain without additional power consumption by reusing the DC bias current of the LO stage. This downconversion double-balanced mixer exhibits a high and flat conversion gain (CG) of 14.9 ± 1.4 dB and a noise figure (NF) better than 12.8 dB. The maximum input 1-dB compression point (P1dB) and maximum input third-order intercept point (IIP3) are -13.6 dBm and -4.5 dBm, respectively, over the desired frequency ranging from 50 MHz to 10 GHz. The proposed circuit operates down to a supply headroom of 1 V with a low-power consumption of 3.5 mW.
Mulcahey, Mary K.; Monchik, Keith O.; Yongpravat, Charlie; Badger, Gary J.; Fadale, Paul D.; Hulstyn, Michael J.; Fleming, Braden C.
2011-01-01
The purpose of this study was to compare tibiofemoral (TF) kinematics and TF compressive stresses between single bundle- (SB-) and double bundle-ACL reconstruction (DB-ACLR) during simulated squatting. Twelve matched pairs of fresh frozen cadaver knees were utilized. A simulated squat through 100° of knee flexion was performed in the ACL-intact joint. The ACL was transected and SB- and DB-ACLR procedures were performed in one knee of each pair. The squat was repeated. Knee kinematics were measured using a motion tracking system and the TF compressive forces were measured using thin film pressure sensors. The posterior shifts of the tibia for SB- and DB-ACLR knees were significantly greater than the ACL-intact condition for knee flexion angles 0° to 40° (p<.05). However, there was no difference between the SB- and DB-ACLR knees at any flexion angle (0° to 100°; p=.37). SB- and DB-ACLR knees had greater IE rotation than intact knees from 90° through 50° of flexion (p<.05), but not between 40° and full extension. There was no difference between SB- and DB-ACLR knees (p=.68). The TF compressive stresses of the DB-ACLR were significantly lower than intact for all angles except 10° (p=.06), whereas SB-ACLR knees did not differ from intact at flexion angles between 30° and 50° (p>.32). There were no significant differences between the two reconstruction conditions (p=.74). This study showed that there was no difference in the TF kinematics or compressive stresses between SB- and DB-ACLR, and only minor differences when compared to the intact state. PMID:21696962
Smart absorbing property of composites with MWCNTs and carbonyl iron as the filler
NASA Astrophysics Data System (ADS)
Xu, Yonggang; Yuan, Liming; Cai, Jun; Zhang, Deyuan
2013-10-01
A smart absorbing composite was prepared by mixing silicone rubber, multi-walled carbon nanotubes (MWCNTs) and flaky carbonyl iron particles (CIPs) in a two-roll mixer. The complex permittivity and permeability of composites with variable compression strain was measured by the transmission method and dc electric conductivity was measured by the standard four-point contact method, then the reflection loss (RL) could be calculated to evaluate the microwave absorbing ability. The results showed that the applied compression strain made the complex permittivity decrease but not obviously due to the broken original conductive network. The enforcement of the strain on the complex permeability was attributed to the orientation of flaky CIPs. With the compressing strain applied on the composites with thickness 1 mm or 1.5 mm, the RL value decreased (minimum -13.2 dB and -25.1 dB) and the absorbing band (RL<-10 dB) was widened (5.2-10.6 GHz and 4.0-8.4 GHz). While as the composite thickness decreased caused by the compression strain, the RL value still decreased (minimum -12.4 dB and -18.6 dB) and the absorbing band was also broadened (6.5-10.7 GHz and 4.4-10.0 GHz). Thus the smart absorbing property was effective on preparing absorbers with wide absorption band and high absorption ratio.
Transformer-Feedback Interstage Bandwidth Enhancement for MMIC Multistage Amplifiers
NASA Astrophysics Data System (ADS)
Nikandish, Gholamreza; Medi, Ali
2015-02-01
The transformer-feedback (TRFB) interstage bandwidth enhancement technique for broadband multistage amplifiers is presented. Theory of the TRFB bandwidth enhancement and the design conditions for maximum bandwidth, maximally flat gain, and maximally flat group delay are provided. It is shown that the TRFB bandwidth enhancement can provide higher bandwidth compared to the conventional techniques based on reactive impedance matching networks. A three-stage low-noise amplifier (LNA) monolithic microwave integrated circuit with the TRFB between its consecutive stages is designed and implemented in a 0.1- μm GaAs pHEMT process. The TRFB is realized by coupling between the drain bias lines of transistors. The reuse of bias lines leads to bandwidth enhancement without increasing the chip area and power consumption. The LNA features average gain of 23 dB and 3-dB bandwidth of 11-39 GHz. It provides a noise figure of 2.1-3.0 dB and an output 1-dB compression point of 8.6 dBm, while consuming 40 mA of current from a 2-V supply.
Compression Garments, Muscle Contractile Function, and Economy in Trail Runners.
Vercruyssen, Fabrice; Gruet, Mathieu; Colson, Serge S; Ehrstrom, Sabine; Brisswalter, Jeanick
2017-01-01
Physiological mechanisms behind the use of compression garments (CGs) during off-road running are unknown. To investigate the influence of wearing CGs vs conventional running clothing (CON) on muscle contractile function and running economy before and after short-distance trail running. Knee-extensor neuromuscular function and running economy assessed from two 5-min treadmill runs (11 and 14 km/h) were evaluated before and after an 18.6-km short-distance trail run in 12 trained athletes wearing either CGs (stocking + short-tight) or CON. Quadriceps neuromuscular function was assessed from mechanical and EMG recording after maximal percutaneous electrical femoral-nerve stimulations (single-twitch doublets at 10 [Db 10 ] and 100 Hz [Db 100 ] delivered at rest and during maximal quadriceps voluntary contraction [MVC]). Running economy (in mL O 2 · km -1 · kg -1 ) increased after trail running independent of the clothing condition and treadmill speeds (P < .001). Similarly, MVC decreased after CON and CGs conditions (-11% and -13%, respectively, P < .001). For both clothing conditions, a significant decrease in quadriceps voluntary activation, Db 10 , Db 100 , and the low-to-high frequency doublet ratio were observed after trail running (time effect, all P < .01), without any changes in rectus femoris maximal M-wave. Wearing CGs does not reduce physiological alterations induced during short-distance trail running. Further studies should determine whether higher intensity of compression pressure during exercises of longer duration may be effective to induce any physiological benefits in experienced trail runners.
Radio astronomy ultra-low-noise amplifier for operation at 91 cm wavelength in high RFI environment
NASA Astrophysics Data System (ADS)
Korolev, A. M.; Zakharenko, V. V.; Ulyanov, O. M.
2016-02-01
An ultra-low-noise input amplifier intended for a use in a radio telescope operating at 91 cm wavelength is presented. The amplifier noise temperatures are 12.8 ± 1.5 and 10.0 ± 1.5 K at ambient temperatures of 293 and 263 K respectively. The amplifier does not require cryogenic cooling. It can be quickly put in operation thus shortening losses in the telescope observation time. High linearity of the amplifier (output power at 1 dB gain compression P1dB ≥ 22 dBm, output third order intercept point OIP3 ≥ 37 dBm) enables the telescope operation in highly urbanized and industrialized regions. To obtain low noise characteristics along with high linearity, high-electron-mobility field-effect transistors were used in parallel in the circuit developed. The transistors used in the amplifier are cost-effective and commercially available. The circuit solution is recommended for similar devices working in ultra-high frequency band.
Cao, Yu; Brady, Gerald J; Gui, Hui; Rutherglen, Chris; Arnold, Michael S; Zhou, Chongwu
2016-07-26
In this paper, we report record radio frequency (RF) performance of carbon nanotube transistors based on combined use of a self-aligned T-shape gate structure, and well-aligned, high-semiconducting-purity, high-density polyfluorene-sorted semiconducting carbon nanotubes, which were deposited using dose-controlled, floating evaporative self-assembly method. These transistors show outstanding direct current (DC) performance with on-current density of 350 μA/μm, transconductance as high as 310 μS/μm, and superior current saturation with normalized output resistance greater than 100 kΩ·μm. These transistors create a record as carbon nanotube RF transistors that demonstrate both the current-gain cutoff frequency (ft) and the maximum oscillation frequency (fmax) greater than 70 GHz. Furthermore, these transistors exhibit good linearity performance with 1 dB gain compression point (P1dB) of 14 dBm and input third-order intercept point (IIP3) of 22 dBm. Our study advances state-of-the-art of carbon nanotube RF electronics, which have the potential to be made flexible and may find broad applications for signal amplification, wireless communication, and wearable/flexible electronics.
Power Amplifier Linearizer for High Frequency Medical Ultrasound Applications
Choi, Hojong; Jung, Hayong; Shung, K. Kirk
2015-01-01
Power amplifiers (PAs) are used to produce high-voltage excitation signals to drive ultrasonic transducers. A larger dynamic range of linear PAs allows higher contrast resolution, a highly desirable characteristic in ultrasonic imaging. The linearity of PAs can be improved by reducing the nonlinear harmonic distortion components of high-voltage output signals. In this paper, a linearizer circuit is proposed to reduce output signal harmonics when working in conjunction with a PA. The PA performance with and without the linearizer was measured by comparing the output power 1-dB compression point (OP1dB), and the second- and third-order harmonic distortions (HD2 and HD3, respectively). The results show that the PA with the linearizer circuit had higher OP1dB (31.7 dB) and lower HD2 (−61.0 dB) and HD3 (−42.7 dB) compared to those of the PA alone (OP1dB (27.1 dB), HD2 (−38.2 dB), and HD3 (−36.8 dB)) at 140 MHz. A pulse-echo measurement was also performed to further evaluate the capability of the linearizer circuit. The HD2 of the echo signal received by the transducer using a PA with the linearizer (−24.8 dB) was lower than that obtained for the PA alone (−16.6 dB). The linearizer circuit is capable of improving the linearity performance of PA by lowering harmonic distortions. PMID:26622209
Ka-band Ga-As FET noise receiver/device development
NASA Technical Reports Server (NTRS)
Schellenberg, J. M.; Feng, M.; Hackett, L. H.; Watkins, E. T.; Yamasaki, H.
1982-01-01
The development of technology for a 30 GHz low noise receiver utilizing GaAs FET devices exclusively is discussed. This program required single and dual-gate FET devices, low noise FET amplifiers, dual-gate FET mixers, and FET oscillators operating at Ka-band frequencies. A 0.25 micrometer gate FET device, developed with a minimum noise figure of 3.3 dB at 29 GHz and an associated gain of 7.4 dB, was used to fabricate a 3-stage amplifier with a minimum noise figure and associated gain of 4.4 dB and 17 dB, respectively. The 1-dB gain bandwidth of this amplifier extended from below 26.5 GHz to 30.5 GHz. A dual-gate mixer with a 2 dB conversion loss and a minimum noise figure of 10 dB at 29 GHz as well as a dielectric resonator stabilized FET oscillator at 25 GHz for the receiver L0. From these components, a hybrid microwave integrated circuit receiver was constructed which demonstrates a minimum single-side band noise figure of 4.6 dB at 29 GHz with a conversion gain of 17 dB. The output power at the 1-dB gain compression point was -5 dBm.
Comparison between Humphrey Field Analyzer and Micro Perimeter 1 in normal and glaucoma subjects.
Ratra, Vineet; Ratra, Dhanashree; Gupta, Muneeswar; Vaitheeswaran, K
2012-05-01
To determine the correlation between fundus perimetry with Micro Perimeter 1 (MP1) and conventional automated static threshold perimetry using the Humphrey Field Analyzer (HFA) in healthy individuals and in subjects with glaucoma. In this study, we enrolled 45 eyes with glaucoma and 21 eyes of age-matched, healthy individuals. All subjects underwent complete ophthalmic examination. Differential light sensitivity was measured at 21 corresponding points in a rectangular test grid in both MP1 and HFA. Similar examination settings were used with Goldmann III stimulus, stimulus presentation time of 200 ms, and white background illumination (1.27 cd/m(2)). Statistical analysis was done with the SPSS 14 using linear regression and independent t-test. The mean light thresholds of 21 matching points in control group with MP1 and HFA were 14.97 ± 2.64 dB and 30.90 ± 2.08 dB, respectively. In subjects with glaucoma, the mean values were MP1: 11.73 ± 4.36 dB and HFA: 27.96 ± 5.41 dB. Mean difference of light thresholds among the two instruments was 15.86 ± 3.25 dB in normal subjects (P < 0.001) and 16.22 ± 2.77 dB in glaucoma subjects (P < 0.001). Pearson correlation analysis of the HFA and MP1 results for each test point location in both cases and control subjects showed significant positive correlation (controls, r = 0.439, P = 0.047; glaucoma subjects, r = 0.812, P < 0.001). There was no difference between nasal and temporal points but a slight vertical asymmetry was observed with MP1. There are significant and reproducible differences in the differential light threshold in MP1 and HFA in both normal and glaucoma subjects. We found a correction factor of 17.271 for comparison of MP1 with HFA. MP1 appeared to be more sensitive in predicting loss in glaucoma.
X-band T/R switch with body-floating multi-gate PDSOI NMOS transistors
NASA Astrophysics Data System (ADS)
Park, Mingyo; Min, Byung-Wook
2018-03-01
This paper presents an X-band transmit/receive switch using multi-gate NMOS transistors in a silicon-on-insulator CMOS process. For low loss and high power handling capability, floating body multi-gate NMOS transistors are adopted instead of conventional stacked NMOS transistors, resulting in 53% reduction of transistor area. Comparing to the stacked NMOS transistors, the multi gate transistor shares the source and drain region between stacked transistors, resulting in reduced chip area and parasitics. The impedance between bodies of gates in multi-gate NMOS transistors is assumed to be very large during design and confirmed after measurement. The measured input 1 dB compression point is 34 dBm. The measured insertion losses of TX and RX modes are respectively 1.7 dB and 2.0 dB at 11 GHz, and the measured isolations of TX and RX modes are >27 dB and >20 dB in X-band, respectively. The chip size is 0.086 mm2 without pads, which is 25% smaller than the T/R switch with stacked transistors.
Discrimination of rippled-spectrum patterns in noise: A manifestation of compressive nonlinearity
Milekhina, Olga N.; Nechaev, Dmitry I.; Klishin, Vladimir O.
2017-01-01
In normal-hearing listeners, rippled-spectrum discrimination was psychophysically investigated in both silence and with a simultaneous masker background using the following two paradigms: measuring the ripple density resolution with the phase-reversal test and measuring the ripple-shift threshold with the ripple-shift test. The 0.5-oct wide signal was centered on 2 kHz, the signal levels were 50 and 80 dB SPL, and the masker levels varied from 30 to 100 dB SPL. The baseline ripple density resolutions were 8.7 oct-1 and 8.6 oct-1 for the 50-dB and 80-dB signals, respectively. The baseline ripple shift thresholds were 0.015 oct and 0.018 oct for the 50-dB and 80-dB signals, respectively. The maskers were 0.5-oct noises centered on 2 kHz (on-frequency) or 0.75 to 1.25 oct below the signal (off-frequency maskers). The effects of the maskers were as follows: (i) both on- and low-frequency maskers reduced the ripple density resolution and increased the ripple shift thresholds, (ii) the masker levels at threshold (the ripple density resolution decrease down to 3 oct–1 or ripple shift threshold increased up to 0.1 oct) increased with increasing frequency spacing between the signal and masker, (iii) the masker levels at threshold were higher for the 80-dB signal than for the 50-dB signal, and (iv) the difference between the masker levels at threshold for the 50-dB and 80-dB signals decreased with increasing frequency spacing between the masker and signal. Within the 30-dB (from 50 to 80 dB SPL) signal level, the growth of the masker level at threshold was 27.8 dB for the on-frequency masker and 9 dB for the low-frequency masker. It is assumed that the difference between the on- and low-frequency masking of the rippled-spectrum discrimination reflects the cochlear compressive non-linearity. With this assumption, the compression was 0.3 dB/dB. PMID:28346538
Hybrid silica coarse wavelength-division multiplexer transmitter optical subassembly
NASA Astrophysics Data System (ADS)
An, Jun-Ming; Zhang, Jia-Shun; Wang, Liang-Liang; Zhu, Kaiwu; Sun, Bingli; Li, Yong; Hou, Jie; Li, Jian-Guang; Wu, Yuan-Da; Wang, Yue; Yin, Xiao-Jie
2018-01-01
Based on silica arrayed waveguide grating technology, a hybrid integrated transmitter optical subassembly was developed. Four direct-modulating distributed feedback lasers and four focusing microlenses were integrated to a coarse wavelength-division multiplexer (CWDM) on a CuW substrate. The four-channel silica-on-silicon CWDM was fabricated with 1.5% refractive index difference and 20-nm wavelength spacing. The experimental results showed that the output optical power was >3 mW with 45 mA of injection current, the slope efficiency was >0.0833 W/A, and the 3-dB bandwidth was broader than 18.15 GHz. The 1-dB compress points were higher than 18 and 15.8 dBm for frequency of 10 and 18 GHz, respectively.
Assessment of Central Retinal Sensitivity Employing Two Types of Microperimetry Devices
Liu, Hongting; Bittencourt, Millena G.; Wang, Jiangxia; Sophie, Raafay; Annam, Rachel; Ibrahim, Mohamed A.; Sepah, Yasir J.; Moradi, Ahmadreza; Scholl, Hendrik P. N.; Nguyen, Quan Dong
2014-01-01
Purpose To compare the retinal sensitivity measurements obtained with two microperimeters, the Micro-Perimeter 1 (MP-1) and the Optos optical coherence tomography (OCT)/scanning laser ophthalmoscope (SLO) in subjects with and without maculopathies. Methods Forty-five eyes with no known ocular disease and 47 eyes with maculopathies were examined using both microperimeters. A contrast-adjusted scale was applied to resolve the different stimuli and background luminance existing between the two devices. Results There was a strong ceiling effect with the MP-1 in the healthy group, with 90.1% (1136 of 1260) test points clustered at 20 dB. The mean sensitivity for the corresponding points in the OCT/SLO was 25.8 ± 1.9 dB. A floor effect was also observed with the OCT/SLO in the maculopathy group with 9.7% (128 of 1316) points clustered at 9-dB values. The corresponding mean sensitivity in the MP-1 was 1.7 ± 3.9 dB. A regression equation between the two microperimeters was established in the common 10 to19 dB intervals as: OCT/SLO = 15.6 + 0.564 × MP-1 − 0.009 × MP-12 + k (k is an individual point constant; MP-1 coefficient P < 0.001; MP-12 coefficient P = 0.006). Conclusion The OCT/SLO and the MP-1 provide two different ranges of contrasts for microperimetry examination. Broadening the dynamic range may minimize the constraint of the ceiling and floor effect. There is a significant mathematical relationship in the common interval of the contrast scale. Translational Relevance Applying a unified and broadened dynamic range in different types of microperimeters will help to generate consistent clinical reference for measurements. PMID:25237592
Campbell, G M; Tiwari, S; Hofbauer, C; Picke, A-K; Rauner, M; Huber, G; Peña, J A; Damm, T; Barkmann, R; Morlock, M M; Hofbauer, L C; Glüer, C-C
2016-01-01
Type 2 diabetes mellitus increases skeletal fragility; however, the contributing mechanisms and the efficacy of bone-forming agents are unclear. We studied diabetes and parathyroid hormone (PTH) treatment effects on cortical porosity (Ct.Po), non-enzymatic glycation (NEG) and bone mechanics in Zucker diabetic fatty (ZDF) rats. Eleven-week old ZDF diabetic (DB) and non-diabetic (ND) rats were given 75μg/kg PTH (1-84) or vehicle 5days per week over 12weeks. The right femora and L4 vertebrae were excised, micro-CT scanned, and tested in 3-point bending and uniaxial compression, respectively. NEG of the samples was determined using fluorescence. Diabetes increased Ct.Po (vertebra (vert): +40.6%, femur (fem): +15.5% vs. ND group, p<0.05) but had no effect on NEG. PTH therapy reduced vertebral NEG in the ND animals only (-73% vs untreated group, p<0.05), and increased femoral NEG in the DB vs. ND groups (+63%, p<0.05). PTH therapy had no effect on Ct.Po. Diabetes negatively affected bone tissue mechanics where reductions in vertebral maximum strain (-22%) and toughness (-42%) were observed in the DB vs. ND group (p<0.05). PTH improved maximum strain in the vertebra of the ND animals (+21%, p<0.05) but did not have an effect in the DB group. PTH increased femoral maximum strain (+21%) and toughness (+28%) in ND and decreased femoral maximum stress (-13%) and toughness (-27%) in the DB animals (treated vs. untreated, p<0.05). Ct.Po correlated negatively with maximum stress (fem: R=-0.35, p<0.05, vert: R=-0.57, p<0.01), maximum strain (fem: R=-0.35, p<0.05, vert: R=-0.43, p<0.05) and toughness (fem: R=-0.34, p<0.05, vert: R=-0.55, p<0.01), and NEG correlated negatively with toughness at the femur (R=-0.34, p<0.05) and maximum strain at the vertebra (R=-0.49, p<0.05). Diabetes increased cortical porosity and reduced bone mechanics, which were not improved with PTH treatment. PTH therapy alone may worsen diabetic bone mechanics through formation of new bone with high AGEs cross-linking. Optimal treatment regimens must address both improvements of bone mass and glycemic control in order to successfully reduce diabetic bone fragility. This article is part of a Special Issue entitled "Bone and diabetes". Copyright © 2015 Elsevier Inc. All rights reserved.
Experimental implementation of array-compressed parallel transmission at 7 tesla.
Yan, Xinqiang; Cao, Zhipeng; Grissom, William A
2016-06-01
To implement and validate a hardware-based array-compressed parallel transmission (acpTx) system. In array-compressed parallel transmission, a small number of transmit channels drive a larger number of transmit coils, which are connected via an array compression network that implements optimized coil-to-channel combinations. A two channel-to-eight coil array compression network was developed using power splitters, attenuators and phase shifters, and a simulation was performed to investigate the effects of coil coupling on power dissipation in a simplified network. An eight coil transmit array was constructed using induced current elimination decoupling, and the coil and network were validated in benchtop measurements, B1+ mapping scans, and an accelerated spiral excitation experiment. The developed attenuators came within 0.08 dB of the desired attenuations, and reflection coefficients were -22 dB or better. The simulation demonstrated that up to 3× more power was dissipated in the network when coils were poorly isolated (-9.6 dB), versus well-isolated (-31 dB). Compared to split circularly-polarized coil combinations, the additional degrees of freedom provided by the array compression network led to 54% lower squared excitation error in the spiral experiment. Array-compressed parallel transmission was successfully implemented in a hardware system. Further work is needed to develop remote network tuning and to minimize network power dissipation. Magn Reson Med 75:2545-2552, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
An inductorless multi-mode RF front end for GNSS receiver in 55 nm CMOS
NASA Astrophysics Data System (ADS)
Yanbin, Luo; Chengyan, Ma; Yebing, Gan; Min, Qian; Tianchun, Ye
2015-10-01
An inductorless multi-mode RF front end for a global navigation satellite system (GNSS) receiver is presented. Unlike the traditional topology of a low noise amplifier (LNA), the inductorless current-mode noise-canceling LNA is applied in this design. The high-impedance-input radio frequency amplifier (RFA) further amplifies the GNSS signals and changes the single-end signal path into fully differential. The passive mixer down-converts the signals to the intermediate frequency (IF) band and conveys the signals to the analogue blocks. The local oscillator (LO) buffer divides the output frequency of the voltage controlled oscillator (VCO) and generates 25%-duty-cycle quadrature square waves to drive the mixer. Our measurement results display that the implemented RF front end achieves good overall performance while consuming only 6.7 mA from 1.2 V supply. The input return loss is better than -26 dB and the ultra low noise figure of 1.43 dB leads to high sensitivity of the GNSS receiver. The input 1 dB compression point is -43 dBm at the high gain of 48 dB. The designed circuit is fabricated in 55 nm CMOS technology and the die area, which is much smaller than traditional circuit, is around 220 × 280 μm2.
[Effects of infrasound on visual electrophysiology in mice].
Shi, Li; Zhang, Zuo-ming; Chen, Jing-zao; Liu, Jing
2003-04-01
To investigate the possible effects of infrasound on visual functions. One hundred and fifty mature male Kunming-mice were divided into 5 groups, in which one was control and the other four were exposed to infrasound of 8 Hz, 90 dB; 8 Hz, 130 dB; 16 Hz, 90 dB and 16 Hz, 130 dB 2 h/d respectively. The exposure time for them were 0, 1, 4, 7, 14 and 21 d respectively, each group was divided into 6 sub-groups. Electroretinogram (ERG), oscillatory potentials (OPs), and visual evoked potential (VEP) were recorded after exposure. The visual electrophysiological indices after 8 Hz, 90 dB and 16 Hz, 90 dB exposures were similar except for a little difference at some temporal points (P<0.05). Most of the indices in 8 Hz, 130 dB group changed after 7 d exposure, and the longer the exposure, the more obvious changes were observed (P<0.01). The indices in 16 Hz, 130 dB group changed obviously after 1 d and reversed with increase of exposure time (P<0.01). The effect of infrasound on visual functions are related to its frequency and intensity. Infrasound of different frequencies causes different levels of retinal resonance, which leads to different degrees of cellular lesion and produces different electrical potentials.
Millimeter-wave pseudomorphic HEMT MMIC phased array components for space communications
NASA Technical Reports Server (NTRS)
Lan, G. L.; Pao, C. K.; Wu, C. S.; Mandolia, G.; Hu, M.; Yuan, S.; Leonard, Regis
1991-01-01
Recent advances in pseudomorphic HEMT MMIC (PMHEMT/MMIC) technology have made it the preferred candidate for high performance millimeter-wave components for phased array applications. This paper describes the development of PMHEMT/MMIC components at Ka-band and V-band. Specifically, the following PMHEMT/MMIC components will be described: power amplifiers at Ka-band; power amplifiers at V-band; and four-bit phase shifters at V-band. For the Ka-band amplifier, 125 mW output power with 5.5 dB gain and 21 percent power added efficiency at 2 dB compression point has been achieved. For the V-band amplifier, 112 mW output power with 6 dB gain and 26 percent power added efficiency has been achieved. And, for the V-band phase shifter, four-bit (45 deg steps) phase shifters with less than 8 dB insertion loss from 61 GHz to 63 GHz will be described.
Optimized satellite image compression and reconstruction via evolution strategies
NASA Astrophysics Data System (ADS)
Babb, Brendan; Moore, Frank; Peterson, Michael
2009-05-01
This paper describes the automatic discovery, via an Evolution Strategy with Covariance Matrix Adaptation (CMA-ES), of vectors of real-valued coefficients representing matched forward and inverse transforms that outperform the 9/7 Cohen-Daubechies-Feauveau (CDF) discrete wavelet transform (DWT) for satellite image compression and reconstruction under conditions subject to quantization error. The best transform evolved during this study reduces the mean squared error (MSE) present in reconstructed satellite images by an average of 33.78% (1.79 dB), while maintaining the average information entropy (IE) of compressed images at 99.57% in comparison to the wavelet. In addition, this evolved transform achieves 49.88% (3.00 dB) average MSE reduction when tested on 80 images from the FBI fingerprint test set, and 42.35% (2.39 dB) average MSE reduction when tested on a set of 18 digital photographs, while achieving average IE of 104.36% and 100.08%, respectively. These results indicate that our evolved transform greatly improves the quality of reconstructed images without substantial loss of compression capability over a broad range of image classes.
High-performance 1.3-μm laser diode by LP-MOVPE
NASA Astrophysics Data System (ADS)
Li, TongNing; Ji, Jin-yan; Yan, Xin-min; Liu, Tao; Ning, Zhou; Liu, Jiang; Liu, Zi-li; Huang, Ge-fan
1996-09-01
The progress in 1.3 micrometers wavelength InGaAsP/InP lasers for optic fiber communication and subscriber loop applications is reviewed. By using LP-MOVPE/LPE epitaxy techniques, the performance of commercial optical devices is considerably improved. The bandwidth of the 1.3 micrometers uncooled MQW-LD module could be high to 1.6GHz, threshold current Ith < 15mA, maximum fiber output power Pf >= 20mW while uniformity, reproducible, high yield are achieved. Further by growing active layer with compressive strained structure the lowest threshold current Ith equals 3.8mA was achieved with high reflection coating and the temperature performance of the SL-MQW-LD has been greatly improved, the change of slop efficiency at 25 degrees C and 85 degrees C is less than 1 dB. Using the holographic technique a high power 1.31 micrometers InGaAsP/InP multiquantum well distributed feedback laser has also been developed. The fiber output power of butterfly packaged module with optic isolator Pf > 10mW, threshold current Ith < 18mA, slop efficiency Es > 22 percent and side mode suppression ratio SMSR > 40dB. The composite triple beat CTB < -66dBc and the composite second order CSO < -56dBc by test frequencies equals 55.25 to approximately 289.25MHz with 40 NCTA channels, the carrier to noise ration CNR > 50 dB and the relative intensity noise RIN < -160dB/Hz.
Infrasound-induced changes on sexual behavior in male rats and some underlying mechanisms.
Zhuang, Zhiqiang; Pei, Zhaohui; Chen, Jingzao
2007-01-01
To investigate some bioeffects of infrasound on copulation as well as underlying mechanisms, we inspected the changes of sexual behavior, serum testosterone concentration and mRNA expression levels of steroidogenic factor 1 (SF-1), steroidogenic acute regulatory protein (StAR) and cytochrome P450 cholesterol side chain cleavage enzyme (P450scc) in testes of rats exposed to infrasound of 8Hz at 90 or 130dB for 1, 7, 14 and 21 days (2h/day), respectively. Rats exposed to 90dB exhibited significant decrement in sexual behavior, serum testosterone levels and mRNA expression levels of StAR and P450scc at the time point of 1 day but not at the rest time points, and no significantly change of SF-1 mRNA expression was observed over the period of 21 days in spite of mild fluctuation. Rats exposed to 130dB exhibited significant decrement in all aspects above, which became more profound with prolonged exposure. Our conclusion is that adverse bioeffects of infrasound on reproduction depend on some exposure parameters, the mechanism of which could involve in the decreased expression of some key enzymes or regulator for testosterone biosynthesis. Copyright © 2006. Published by Elsevier B.V.
Range side lobe inversion for chirp-encoded dual-band tissue harmonic imaging.
Shen, Che-Chou; Peng, Jun-Kai; Wu, Chi
2014-02-01
Dual-band (DB) harmonic imaging is performed by transmitting and receiving at both fundamental band (f0) and second-harmonic band (2f0). In our previous work, particular chirp excitation has been developed to increase the signal- to-noise ratio in DB harmonic imaging. However, spectral overlap between the second-order DB harmonic signals results in range side lobes in the pulse compression. In this study, a novel range side lobe inversion (RSI) method is developed to alleviate the level of range side lobes from spectral overlap. The method is implemented by firing an auxiliary chirp to change the polarity of the range side lobes so that the range side lobes can be suppressed in the combination of the original chirp and the auxiliary chirp. Hydrophone measurements show that the RSI method reduces the range side lobe level (RSLL) and thus increases the quality of pulse compression in DB harmonic imaging. With the signal bandwidth of 60%, the RSLL decreases from -23 dB to -36 dB and the corresponding compression quality improves from 78% to 94%. B-mode images also indicate that the magnitude of range side lobe is suppressed by 7 dB when the RSI method is applied.
NASA Astrophysics Data System (ADS)
Hwang, Yuh-Jing; Chiong, Chau-Ching; Huang, Yau-De; Huang, Chi-Den; Liu, Ching-Tang; Kuo, Yue-Fang; Weng, Shou-Hsien; Ho, Chin-Ting; Chiang, Po-Han; Wu, Hsiao-Ling; Chang, Chih-Cheng; Jian, Shou-Ting; Lee, Chien-Feng; Lee, Yi-Wei; Pospieszalski, Marian; Henke, Doug; Finger, Ricardo; Tapia, Valeria; Gonzalez, Alvaro
2016-07-01
The ALMA Band-1 receiver front-end prototype cold and warm cartridge assemblies, including the system and key components for ALMA Band-1 receivers have been developed and two sets of prototype cartridge were fully tested. The measured aperture efficiency for the cold receiver is above the 80% specification except for a few frequency points. Based on the cryogenically cooled broadband low-noise amplifiers provided by NRAO, the receiver noise temperature can be as low as 15 - 32K for pol-0 and 17 - 30K for pol-1. Other key testing items are also measured. The receiver beam pattern is measured, the results is well fit to the simulation and design. The pointing error extracted from the measured beam pattern indicates the error is 0.1 degree along azimuth and 0.15 degree along elevation, which is well fit to the specification (smaller than 0.4 degree). The equivalent hot load temperature for 5% gain compression is 492 - 4583K, which well fit to the specification of 5% with 373K input thermal load. The image band suppression is higher than 30 dB typically and the worst case is higher than 20 dB for 34GHz RF signal and 38GHz LO signal, which is all higher than 7 dB required specification. The cross talk between orthogonal polarization is smaller than -85 dB based on present prototype LO. The amplitude stability is below 2.0 x 10-7 , which is fit to the specification of 4.0 x 10-7 for timescales in the range of 0.05 s ≤ T ≤ 100 s. The signal path phase stability measured is smaller than 5 fs, which is smaller than 22 fs for Long term (delay drift) 20 s ≤ T < 300 sec. The IF output phase variation is smaller than 3.5° rms typically, and the specification is less than 4.5° rms. The measured IF output power level is -28 to -30.5 dBm with 300K input load. The measured IF output power flatness is less than 5.6 dB for 2GHz window, and 1.3dB for 31MHz window. The first batch of prototype cartridges will be installed on site for further commissioning on July of 2017.
Modified Point Mass Trajectory Simulation for Base-Burn Projectiles
1992-03-01
Konrad Adenauer Ufer 2-6 1 DGAM 54 Koblenz ATTN: Mr. J.L. Perez Minguez GERMANY Poligono de Experiencias Paseo de Extremedura WTD 91 D. BW-031 28024...directly related to the average projectile base pressure, Pb, as follows: 1 Pb Cob YM2_ (1) 2 db2 where: db = base diameter of projectile in calibers M...and p v Ab is the free-stream mass flow through an area equal to the base of the projectile, Ab. Danberg (1990) has shown that ABP is linearly related
Markowitz, Michael; Fu, Dong-Jing; Levitan, Bennett; Gopal, Srihari; Turkoz, Ibrahim; Alphs, Larry
2013-07-11
Increasing availability and use of long-acting injectable antipsychotics have generated a need to compare these formulations with their oral equivalents; however, a paucity of relevant data is available. This post hoc comparison of the long-term efficacy, safety and tolerability of maintenance treatment with paliperidone palmitate (PP) versus oral paliperidone extended release (ER) used data from two similarly designed, randomised, double-blind (DB), placebo-controlled schizophrenia relapse prevention trials. Assessments included measures of time to relapse, symptom changes/functioning and treatment-emergent adverse events (TEAEs). Time to relapse between treatment groups was evaluated using a Cox proportional hazards model. Between-group differences for continuous variables for change scores during the DB phase were assessed using analysis of co-variance models. Categorical variables were evaluated using Chi-square and Fisher's exact tests. No adjustment was made for multiplicity. Approximately 45% of enrolled subjects in both trials were stabilised and randomised to the DB relapse prevention phase. Risk of relapse was higher in subjects treated with paliperidone ER than in those treated with PP [paliperidone ER/PP hazard ratio (HR), 2.52; 95% confidence interval (CI), 1.46-4.35; p < 0.001]. Similarly, risk of relapse after withdrawal of paliperidone ER treatment (placebo group of the paliperidone ER study) was higher than after withdrawal of PP (paliperidone ER placebo/PP placebo HR, 2.25; 95% CI, 1.59-3.18; p < 0.001). Stabilised schizophrenic subjects treated with PP maintained functioning demonstrated by the same proportions of subjects with mild to no difficulties in functioning at DB baseline and end point [Personal and Social Performance (PSP) scale total score >70, both approximately 58.5%; p = 1.000] compared with a 10.9% decrease for paliperidone ER (58.5% vs 47.6%, respectively; p = 0.048). The least squares mean change for Positive and Negative Syndrome Scale (PANSS) total score at DB end point in these previously stabilised subjects was 3.5 points in favour of PP (6.0 vs 2.5; p = 0.025). The rates of TEAEs and AEs of interest appeared similar. This analysis supports maintenance of effect with the injectable compared with the oral formulation of paliperidone in patients with schizophrenia. The safety profile of PP was similar to that of paliperidone ER. Future studies are needed to confirm these findings.
P³DB 3.0: From plant phosphorylation sites to protein networks.
Yao, Qiuming; Ge, Huangyi; Wu, Shangquan; Zhang, Ning; Chen, Wei; Xu, Chunhui; Gao, Jianjiong; Thelen, Jay J; Xu, Dong
2014-01-01
In the past few years, the Plant Protein Phosphorylation Database (P(3)DB, http://p3db.org) has become one of the most significant in vivo data resources for studying plant phosphoproteomics. We have substantially updated P(3)DB with respect to format, new datasets and analytic tools. In the P(3)DB 3.0, there are altogether 47 923 phosphosites in 16 477 phosphoproteins curated across nine plant organisms from 32 studies, which have met our multiple quality standards for acquisition of in vivo phosphorylation site data. Centralized by these phosphorylation data, multiple related data and annotations are provided, including protein-protein interaction (PPI), gene ontology, protein tertiary structures, orthologous sequences, kinase/phosphatase classification and Kinase Client Assay (KiC Assay) data--all of which provides context for the phosphorylation event. In addition, P(3)DB 3.0 incorporates multiple network viewers for the above features, such as PPI network, kinase-substrate network, phosphatase-substrate network, and domain co-occurrence network to help study phosphorylation from a systems point of view. Furthermore, the new P(3)DB reflects a community-based design through which users can share datasets and automate data depository processes for publication purposes. Each of these new features supports the goal of making P(3)DB a comprehensive, systematic and interactive platform for phosphoproteomics research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukherjee, S; Yao, W
2015-06-15
Purpose: To study different noise-reduction algorithms and to improve the image quality of low dose cone beam CT for patient positioning in radiation therapy. Methods: In low-dose cone-beam CT, the reconstructed image is contaminated with excessive quantum noise. In this study, three well-developed noise reduction algorithms namely, a) penalized weighted least square (PWLS) method, b) split-Bregman total variation (TV) method, and c) compressed sensing (CS) method were studied and applied to the images of a computer–simulated “Shepp-Logan” phantom and a physical CATPHAN phantom. Up to 20% additive Gaussian noise was added to the Shepp-Logan phantom. The CATPHAN phantom was scannedmore » by a Varian OBI system with 100 kVp, 4 ms and 20 mA. For comparing the performance of these algorithms, peak signal-to-noise ratio (PSNR) of the denoised images was computed. Results: The algorithms were shown to have the potential in reducing the noise level for low-dose CBCT images. For Shepp-Logan phantom, an improvement of PSNR of 2 dB, 3.1 dB and 4 dB was observed using PWLS, TV and CS respectively, while for CATPHAN, the improvement was 1.2 dB, 1.8 dB and 2.1 dB, respectively. Conclusion: Penalized weighted least square, total variation and compressed sensing methods were studied and compared for reducing the noise on a simulated phantom and a physical phantom scanned by low-dose CBCT. The techniques have shown promising results for noise reduction in terms of PSNR improvement. However, reducing the noise without compromising the smoothness and resolution of the image needs more extensive research.« less
Cost-effective TCM-based WDM-PON for highly asymmetric traffic conditions.
Lee, Danbi; Kwon, Won-Bae; Chae, Chang-Joon; Park, Chang-Soo
2015-11-16
A time compression multiplexing (TCM)-based wavelength division multiplexing passive optical network (WDM-PON) using a reflective semiconductor optical amplifier (RSOA) is proposed, and its feasibility is experimentally demonstrated. In the proposed system, the RSOA pre-amplifies a 10 Gb/s downstream signal and modulates the RSOA output, wavelength-locked to the downstream signal, with a 1.25 Gb/s upstream signal simultaneously. The sensitivity of the downstream signal is improved by about 3 dB through the RSOA. The downstream and upstream signals have power penalties of about 0.1 dB and 1.1 dB, respectively, at bit error rates (BERs) of 10(-9) after 20 km transmission.
Nesnow, S; Davis, C; Padgett, W T; Adams, L; Yacopucci, M; King, L C
2000-06-01
The comparative genotoxic effects of racemic trans-8,9-dihydroxy-8, 9-dihydrodibenzo[a,l]pyrene (trans-DB[a,l]P-8,9-diol), the metabolic K-region dihydrodiol of dibenzo[a,l] pyrene (DB[a,l]P) (dibenzo[def, p]chrysene) and DB[a,l]P in transformable mouse embryo C3H10T(1)/(2)Cl8 (C3H10T(1)/(2)) fibroblasts was investigated. The C3H10T(1)/(2) mouse embryo morphological cell-transforming activities of these polycyclic aromatic hydrocarbons (PAHs) were assayed using concentration-response studies. At concentrations of 33 nM and above both trans-DB[a,l]P-8,9-diol and DB[a,l]P produced significant (and similar) numbers of type II and III foci per dish and numbers of dishes with type II and II foci. Concomitant cytotoxicity studies revealed a reduction in colony survival of approximately 25% up to 198 nM for both PAHs. DNA adducts of trans-DB[a,l]P-8,9-diol and DB[a,l]P in C3H10T(1)/(2) cells were analyzed by a (32)P-post-labeling TLC/HPLC method. No adducts were observed in the DNA of C3H10T(1)/(2) cells treated with trans-DB[a, l]P-8,9-diol at concentrations that induced morphological cell transformation. Under the same exposure and chromatographic conditions, DNA adducts of deoxyadenosine and deoxyguanosine derived from the fjord region anti-DB[a,l]P-11,12-diol-13,14-epoxide and syn-DB[a,l]P-11,12-diol-13,14-epoxide were observed in the DNA of DB[a,l]P-treated cells. These results indicate that trans-DB[a,l]P-8, 9-diol has intrinsic genotoxic activity equal to that of DB[a,l]P, based on morphological cell transformation of mouse embryo fibroblasts. The activity of trans-DB[a,l]P-8,9-diol is apparently not associated with the formation of observable stable covalent DNA adducts. These results suggest that under appropriate conditions, trans-DB[a,l]P-8,9-diol may serve as an intermediate in the genotoxicity of DB[a,l]P.
Distractions during critical phases of anaesthesia for caesarean section: an observational study.
Jenkins, A; Wilkinson, J V; Akeroyd, M A; Broom, M A
2015-05-01
Aviation's 'sterile cockpit' rule holds that distractions on the flight deck should be kept at a minimum during critical phases of flight. To assess current practice at comparable points during obstetric regional anaesthesia, we measured ambient noise and distracting events during 30 caesarean sections in three phases: during establishment of regional anaesthesia; during testing of regional blockade; and after delivery of the fetal head. Mean (SD) noise levels were 62.5 (3.9) dB during establishment of blockade, 63.9 (4.1) dB during testing and 66.8 (5.0) dB after delivery (p < 0.001). The median rates of sudden, loud (> 70 dB) noises, non-clinical conversations and numbers of staff present in the operating theatre increased during each of the three phases. Conversely, entrances into, and exits from, theatre per minute were highest during establishment of regional anaesthesia and decreased over the subsequent two time periods (p < 0.001). © 2014 The Association of Anaesthetists of Great Britain and Ireland.
Ultrasonic data compression via parameter estimation.
Cardoso, Guilherme; Saniie, Jafar
2005-02-01
Ultrasonic imaging in medical and industrial applications often requires a large amount of data collection. Consequently, it is desirable to use data compression techniques to reduce data and to facilitate the analysis and remote access of ultrasonic information. The precise data representation is paramount to the accurate analysis of the shape, size, and orientation of ultrasonic reflectors, as well as to the determination of the properties of the propagation path. In this study, a successive parameter estimation algorithm based on a modified version of the continuous wavelet transform (CWT) to compress and denoise ultrasonic signals is presented. It has been shown analytically that the CWT (i.e., time x frequency representation) yields an exact solution for the time-of-arrival and a biased solution for the center frequency. Consequently, a modified CWT (MCWT) based on the Gabor-Helstrom transform is introduced as a means to exactly estimate both time-of-arrival and center frequency of ultrasonic echoes. Furthermore, the MCWT also has been used to generate a phase x bandwidth representation of the ultrasonic echo. This representation allows the exact estimation of the phase and the bandwidth. The performance of this algorithm for data compression and signal analysis is studied using simulated and experimental ultrasonic signals. The successive parameter estimation algorithm achieves a data compression ratio of (1-5N/J), where J is the number of samples and N is the number of echoes in the signal. For a signal with 10 echoes and 2048 samples, a compression ratio of 96% is achieved with a signal-to-noise ratio (SNR) improvement above 20 dB. Furthermore, this algorithm performs robustly, yields accurate echo estimation, and results in SNR enhancements ranging from 10 to 60 dB for composite signals having SNR as low as -10 dB.
A 5.2/5.8 GHz Dual Band On-Off Keying Transmitter Design for Bio-Signal Transmission
NASA Astrophysics Data System (ADS)
Wu, Chang-Hsi; You, Hong-Cheng; Huang, Shun-Zhao
2018-02-01
An architecture of 5.2/5.8-GHz dual-band on-off keying (DBOOK) modulated transmitter is designed in a 0.18-μm CMOS technology. The proposed DBOOK transmitter is used in the biosignal transmission system with high power efficiency and small area. To reduce power consumption and enhance output swing, two pairs of center-tapped transformers are used as both LC tank and source grounding choke for the designed voltage controlled oscillator (VCO). Switching capacitances are used to achieve dual band operations, and a complemented power combiner is used to merge the differential output power of VCO to a single-ended output. Besides, the linearizer circuits are used in the proposed power amplifier with wideband output matching to improve the linearity both at 5.2/5.8-GHz bands. The designed DBOOK transmitter is implemented by dividing it into two chips. One chip implements the dual-band switching VCO and power combiner, and the other chip implements a linear power amplifier including dual-band operation. The first chip drives an output power of 2.2mW with consuming power of 5.13 mW from 1.1 V supply voltage. With the chip size including pad of 0.61 × 0.91 m2, the measured data rate and transmission efficiency attained are 100 Mb/s and 51 pJ/bit, respectively. The second chip, for power enhanced mode, exhibits P1 dB of -9 dBm, IIP3 of 1 dBm, the output power 1 dB compression point of 12.42 dBm, OIP3 of about 21 dBm, maximum output power of 17.02/16.18 dBm, and power added efficiency of 17.13/16.95% for 5.2/ 5.8 GHz. The chip size including pads is 0:693 × 1:084mm2.
Moore, Brian C J; Füllgrabe, Christian; Stone, Michael A
2011-01-01
To determine preferred parameters of multichannel compression using individually fitted simulated hearing aids and a method of paired comparisons. Fourteen participants with mild to moderate hearing loss listened via a simulated five-channel compression hearing aid fitted using the CAMEQ2-HF method to pairs of speech sounds (a male talker and a female talker) and musical sounds (a percussion instrument, orchestral classical music, and a jazz trio) presented sequentially and indicated which sound of the pair was preferred and by how much. The sounds in each pair were derived from the same token and differed along a single dimension in the type of processing applied. For the speech sounds, participants judged either pleasantness or clarity; in the latter case, the speech was presented in noise at a 2-dB signal-to-noise ratio. For musical sounds, they judged pleasantness. The parameters explored were time delay of the audio signal relative to the gain control signal (the alignment delay), compression speed (attack and release times), bandwidth (5, 7.5, or 10 kHz), and gain at high frequencies relative to that prescribed by CAMEQ2-HF. Pleasantness increased with increasing alignment delay only for the percussive musical sound. Clarity was not affected by alignment delay. There was a trend for pleasantness to decrease slightly with increasing bandwidth, but this was significant only for female speech with fast compression. Judged clarity was significantly higher for the 7.5- and 10-kHz bandwidths than for the 5-kHz bandwidth for both slow and fast compression and for both talker genders. Compression speed had little effect on pleasantness for 50- or 65-dB SPL input levels, but slow compression was generally judged as slightly more pleasant than fast compression for an 80-dB SPL input level. Clarity was higher for slow than for fast compression for input levels of 80 and 65 dB SPL but not for a level of 50 dB SPL. Preferences for pleasantness were approximately equal with CAMEQ2-HF gains and with gains slightly reduced at high frequencies and were lower when gains were slightly increased at high frequencies. Speech clarity was not affected by changing the gain at high frequencies. Effects of alignment delay were small except for the percussive sound. A wider bandwidth was slightly preferred for speech clarity. Speech clarity was slightly greater with slow compression, especially at high levels. Preferred high-frequency gains were close to or a little below those prescribed by CAMEQ2-HF.
Mochizuki, Futa; Kagawa, Keiichiro; Okihara, Shin-ichiro; Seo, Min-Woong; Zhang, Bo; Takasawa, Taishi; Yasutomi, Keita; Kawahito, Shoji
2016-02-22
In the work described in this paper, an image reproduction scheme with an ultra-high-speed temporally compressive multi-aperture CMOS image sensor was demonstrated. The sensor captures an object by compressing a sequence of images with focal-plane temporally random-coded shutters, followed by reconstruction of time-resolved images. Because signals are modulated pixel-by-pixel during capturing, the maximum frame rate is defined only by the charge transfer speed and can thus be higher than those of conventional ultra-high-speed cameras. The frame rate and optical efficiency of the multi-aperture scheme are discussed. To demonstrate the proposed imaging method, a 5×3 multi-aperture image sensor was fabricated. The average rising and falling times of the shutters were 1.53 ns and 1.69 ns, respectively. The maximum skew among the shutters was 3 ns. The sensor observed plasma emission by compressing it to 15 frames, and a series of 32 images at 200 Mfps was reconstructed. In the experiment, by correcting disparities and considering temporal pixel responses, artifacts in the reconstructed images were reduced. An improvement in PSNR from 25.8 dB to 30.8 dB was confirmed in simulations.
Wavelet-based audio embedding and audio/video compression
NASA Astrophysics Data System (ADS)
Mendenhall, Michael J.; Claypoole, Roger L., Jr.
2001-12-01
Watermarking, traditionally used for copyright protection, is used in a new and exciting way. An efficient wavelet-based watermarking technique embeds audio information into a video signal. Several effective compression techniques are applied to compress the resulting audio/video signal in an embedded fashion. This wavelet-based compression algorithm incorporates bit-plane coding, index coding, and Huffman coding. To demonstrate the potential of this audio embedding and audio/video compression algorithm, we embed an audio signal into a video signal and then compress. Results show that overall compression rates of 15:1 can be achieved. The video signal is reconstructed with a median PSNR of nearly 33 dB. Finally, the audio signal is extracted from the compressed audio/video signal without error.
Efficacy of the Amsler Grid Test in Evaluating Glaucomatous Central Visual Field Defects.
Su, Daniel; Greenberg, Andrew; Simonson, Joseph L; Teng, Christopher C; Liebmann, Jeffrey M; Ritch, Robert; Park, Sung Chul
2016-04-01
To investigate the efficacy of the Amsler grid test in detecting central visual field (VF) defects in glaucoma. Prospective, cross-sectional study. Patients with glaucoma with reliable Humphrey 10-2 Swedish Interactive Threshold Algorithm standard VF on the date of enrollment or within the previous 3 months. Amsler grid tests were performed for each eye and were considered "abnormal" if there was any perceived scotoma with missing or blurry grid lines within the central 10 degrees ("Amsler grid scotoma"). An abnormal 10-2 VF was defined as ≥3 adjacent points at P < 0.01 with at least 1 point at P < 0.005 in the same hemifield on the pattern deviation plot. Sensitivity, specificity, and positive and negative predictive values of the Amsler grid scotoma area were calculated with the 10-2 VF as the clinical reference standard. Among eyes with an abnormal 10-2 VF, regression analyses were performed between the Amsler grid scotoma area and the 10-2 VF parameters (mean deviation [MD], scotoma extent [number of test points with P < 0.01 in total deviation map] and scotoma mean depth [mean sensitivity of test points with P < 0.01 in total deviation map]). Sensitivity, specificity, and positive and negative predictive values of the Amsler grid scotoma area. A total of 106 eyes (53 patients) were included (mean ± standard deviation age, 24-2 MD and 10-2 MD = 66±12 years, -9.61±8.64 decibels [dB] and -9.75±9.00 dB, respectively). Sensitivity, specificity, and positive and negative predictive values of the Amsler grid test were 68%, 92%, 97%, and 46%, respectively. Sensitivity was 40% in eyes with 10-2 MD better than -6 dB, 58% in eyes with 10-2 MD between -12 and -6 dB, and 92% in eyes with 10-2 MD worse than -12 dB. The area under the receiver operating characteristic curve of the Amsler grid scotoma area was 0.810 (95% confidence interval, 0.723-0.880, P < 0.001). The Amsler grid scotoma area had the strongest relationship with 10-2 MD (quadratic R(2)=0.681), followed by 10-2 scotoma extent (quadratic R(2)=0.611) and 10-2 scotoma mean depth (quadratic R(2)=0.299) (all P < 0.001). The Amsler grid can be used to screen for moderate to severe central vision loss from glaucoma. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Dynamics of road traffic noise in Bhadrak city, India.
Swain, Bijay Kumar; Panda, Santosh Kumar; Goswami, Shreerup
2012-11-01
Road traffic noise assessed in 13 different squares of major intersection points in Bhadrak city during four different specified times i.e. 7-10 a.m., 11 a.m.-2 p.m., 3-6 p.m. and 7-10 p.m.. Road traffic was found to be the most important source of community noise at the studied sites. The noise levels of all the 13 squares were found to be beyond the permissible limit [70 dB (A)] during day time. Leq (equivalent noise level) values ranged from 93.4 to 100.5; 91.5 to 100.6; 95.1 to 107.3 and 97.3 to 106.3 dB during 7-10 a.m., 11 a.m.-2 p.m., 3-6 p.m. and 7-10 p.m. respectively. LNP values range from 115.7 to 127.7; 114.2 to 129.8; 118.2 to 138.2 and 120.7 to 135 dB, while TNI values range from 134.3 to 154.7; 130.7 to 157.9; 136.7 to 168.2 and 137.2 to 165 dB during 7-10 a.m., 11 a.m.-2 p.m., 3-6 p.m. and 7-10 p.m. respectively. Reprehensibly, even minimum LNP and TNI values are more than 114 and 130 dB respectively. Analysis of variance also computed for investigated squares at the peak hour i.e. 7-10 p.m. to infer the level of significance. The observed value of F (0.47) was less than the tabulated values and was not significant at both 5 and 1% levels of significance. Thus, the noise levels of different squares did not differ significantly at their peak hours. A preliminary public health survey carried out based on questionnaire method amongst 202 local inhabitants reveal the degree of annoyance due to road traffic noise.
Anti-liver-kidney microsome antibody type 1 recognizes human cytochrome P450 db1.
Gueguen, M; Yamamoto, A M; Bernard, O; Alvarez, F
1989-03-15
Anti-liver-kidney microsome antibody type 1 (LKM1), present in the sera of a group of children with autoimmune hepatitis, was recently shown to recognize a 50 kDa protein identified as rat liver cytochromes P450 db1 and db2. High homology between these two members of the rat P450 IID subfamily and human P450 db1 suggested that anti-LKM1 antibody is directed against this human protein. To test this hypothesis, a human liver cDNA expression library in phage lambda GT-11 was screened using rat P450 db1 cDNA as a probe. Two human cDNA clones were found to be identical to human P450 db1 by restriction mapping. Immunoblot analysis using as antigen, the purified fusion protein from one of the human cDNA clones showed that only anti-LKM1 with anti-50 kDa reactivity recognized the fusion protein. This fusion protein was further used to develop an ELISA test that was shown to be specific for sera of children with this disease. These results: 1) identify the human liver antigen recognized by anti-LKM1 auto-antibodies as cytochrome P450 db1, 2) allow to speculate that mutation on the human P450 db1 gene could alter its expression in the hepatocyte and make it auto-antigenic, 3) provide a simple and specific diagnostic test for this disease.
Reinforced cementitous composite with in situ shrinking microfibers
NASA Astrophysics Data System (ADS)
Kim, Eric S.; Lee, Jason K.; Lee, Patrick C.; Huston, Dryver R.; Tan, Ting; Al-Ghamdi, Saleh
2017-03-01
This paper describes an innovative fiber reinforcement technology for cementitious composite structures that employs in situ shrinking microfibers to provide supplemental strength-enhancing compressive stresses. Reinforced concrete is one of the most commonly used structural materials in construction industry, primarily due to its cost, durability, ability to be easily fabricated into a variety of shapes on site, and locally abundant raw material availability almost everywhere. Unlike incumbent passive reinforcing microfiber technology, in situ shrinking microfibers that respond to an in situ stimulus such as heat, pH, or moisture variations can induce pre-compression to matrix and create additional resistance from external loads, creating stronger composite structures. In this paper, heat-activated-shrinking (HAS) microfibers made from polyolefin, and pH-activated-shrinking (pHAS) microfibers made from chitosan powder were used to study effects of shrinking microfiber reinforcing in concrete. Shrinking ratios and tensile strengths of both microfibers were measured. Cementitious specimens with active shrinking microfibers, passive non shrinking fibers, as well as control samples were made. Mechanical properties of the samples were compared with compression and three-point bending tests. The optimum microfiber weight percentages for HAS microfibers were 0.5 wt% in compression tests, and 1.0 wt% in three-point bending tests. For pHAS microfibers, the optimum weight percentages were 0.5 wt% in three-point bending tests. Compared to heat passive microfibers specimens, 45% increase in the maximum compression strengths, and 124% increase in the maximum bending strengths were achieved at the optimum weight percentages of HAS microfibers. In addition, with 0.5 wt% of pHAS microfibers, 145% increase in the maximum bending strengths of three-point bending tests resulted compared to pH passive microfibers specimens.
Antibodies against human cytochrome P-450db1 in autoimmune hepatitis type II.
Zanger, U M; Hauri, H P; Loeper, J; Homberg, J C; Meyer, U A
1988-11-01
In a subgroup of children with chronic active hepatitis, circulating autoantibodies occur that bind to liver and kidney endoplasmic reticulum (anti-liver/kidney microsome antibody type I or anti-LKM1). Anti-LKM1 titers follow the severity of the disease and the presence of these antibodies serves as a diagnostic marker for this autoimmune hepatitis type II. We demonstrate that anti-LKM1 IgGs specifically inhibit the hydroxylation of bufuralol in human liver microsomes. Using two assay systems with different selectivity for the two cytochrome P-450 isozymes catalyzing bufuralol metabolism in human liver, we show that anti-LKM1 exclusively recognizes cytochrome P-450db1. Immunopurification of the LKM1 antigen from solubilized human liver microsomes resulted in an electrophoretically homogenous protein that had the same molecular mass (50 kDa) as purified P-450db1 and an identical N-terminal amino acid sequence. Recognition of both purified P-450db1 and the immunoisolated protein on western blots by several monoclonal antibodies confirmed the identity of the LKM1 antigen with cytochrome P-450db1. Cytochrome P-450db1 has been identified as the target of a common genetic polymorphism of drug oxidation. However, the relationship between the polymorphic cytochrome P-450db1 and the appearance of anti-LKM1 autoantibodies as well as their role in the pathogenesis of chronic active hepatitis remains speculative.
Comparing NetCDF and SciDB on managing and querying 5D hydrologic dataset
NASA Astrophysics Data System (ADS)
Liu, Haicheng; Xiao, Xiao
2016-11-01
Efficiently extracting information from high dimensional hydro-meteorological modelling datasets requires smart solutions. Traditional methods are mostly based on files, which can be edited and accessed handily. But they have problems of efficiency due to contiguous storage structure. Others propose databases as an alternative for advantages such as native functionalities for manipulating multidimensional (MD) arrays, smart caching strategy and scalability. In this research, NetCDF file based solutions and the multidimensional array database management system (DBMS) SciDB applying chunked storage structure are benchmarked to determine the best solution for storing and querying 5D large hydrologic modelling dataset. The effect of data storage configurations including chunk size, dimension order and compression on query performance is explored. Results indicate that dimension order to organize storage of 5D data has significant influence on query performance if chunk size is very large. But the effect becomes insignificant when chunk size is properly set. Compression of SciDB mostly has negative influence on query performance. Caching is an advantage but may be influenced by execution of different query processes. On the whole, NetCDF solution without compression is in general more efficient than the SciDB DBMS.
Bioinformatics Analysis of Protein Phosphorylation in Plant Systems Biology Using P3DB.
Yao, Qiuming; Xu, Dong
2017-01-01
Protein phosphorylation is one of the most pervasive protein post-translational modification events in plant cells. It is involved in many plant biological processes, such as plant growth, organ development, and plant immunology, by regulating or switching signaling and metabolic pathways. High-throughput experimental methods like mass spectrometry can easily characterize hundreds to thousands of phosphorylation events in a single experiment. With the increasing volume of the data sets, Plant Protein Phosphorylation DataBase (P3DB, http://p3db.org ) provides a comprehensive, systematic, and interactive online platform to deposit, query, analyze, and visualize these phosphorylation events in many plant species. It stores the protein phosphorylation sites in the context of identified mass spectra, phosphopeptides, and phosphoproteins contributed from various plant proteome studies. In addition, P3DB associates these plant phosphorylation sites to protein physicochemical information in the protein charts and tertiary structures, while various protein annotations from hierarchical kinase phosphatase families, protein domains, and gene ontology are also added into the database. P3DB not only provides rich information, but also interconnects and provides visualization of the data in networks, in systems biology context. Currently, P3DB includes the KiC (Kinase Client) assay network, the protein-protein interaction network, the kinase-substrate network, the phosphatase-substrate network, and the protein domain co-occurrence network. All of these are available to query for and visualize existing phosphorylation events. Although P3DB only hosts experimentally identified phosphorylation data, it provides a plant phosphorylation prediction model for any unknown queries on the fly. P3DB is an entry point to the plant phosphorylation community to deposit and visualize any customized data sets within this systems biology framework. Nowadays, P3DB has become one of the major bioinformatics platforms of protein phosphorylation in plant biology.
Antibodies against human cytochrome P-450db1 in autoimmune hepatitis type II.
Zanger, U M; Hauri, H P; Loeper, J; Homberg, J C; Meyer, U A
1988-01-01
In a subgroup of children with chronic active hepatitis, circulating autoantibodies occur that bind to liver and kidney endoplasmic reticulum (anti-liver/kidney microsome antibody type I or anti-LKM1). Anti-LKM1 titers follow the severity of the disease and the presence of these antibodies serves as a diagnostic marker for this autoimmune hepatitis type II. We demonstrate that anti-LKM1 IgGs specifically inhibit the hydroxylation of bufuralol in human liver microsomes. Using two assay systems with different selectivity for the two cytochrome P-450 isozymes catalyzing bufuralol metabolism in human liver, we show that anti-LKM1 exclusively recognizes cytochrome P-450db1. Immunopurification of the LKM1 antigen from solubilized human liver microsomes resulted in an electrophoretically homogenous protein that had the same molecular mass (50 kDa) as purified P-450db1 and an identical N-terminal amino acid sequence. Recognition of both purified P-450db1 and the immunoisolated protein on western blots by several monoclonal antibodies confirmed the identity of the LKM1 antigen with cytochrome P-450db1. Cytochrome P-450db1 has been identified as the target of a common genetic polymorphism of drug oxidation. However, the relationship between the polymorphic cytochrome P-450db1 and the appearance of anti-LKM1 autoantibodies as well as their role in the pathogenesis of chronic active hepatitis remains speculative. Images PMID:3186722
Topical Substance P Increases Inflammatory Cell Density in Genetically Diabetic Murine Wounds
Scott, Jeffrey R; Tamura, Richard N.; Muangman, Pornprom; Isik, F. Frank; Xie, Chengyu; Gibran, Nicole S.
2008-01-01
The neuropeptide substance P (SP) is a known inflammatory mediator released from cutaneous peripheral nerve terminals. SP effects on cellular composition in the cutaneous response to injury remain unclear. Based on our previous observations about SP effects on wound repair, we hypothesized that topical SP increases inflammatory cell density infiltration early after injury. A full thickness 1.5×1.5 cm-square wound was created on the dorsum of 8–9 wk old C57BL/6J-m+Leprdb mice (db/db). Wounds were treated daily with 300μl of either normal saline (0.9% NaCl) or 10−9M SP for seven days. Three wounds from each group were harvested at 2,3,7,14, and 28 days. Samples underwent enzymatic digestion and were incubated with fluorescent-labeled antibodies. Using flow cytometry, cellular content and density for each sample was derived. Masson Trichrome stained histology specimens were prepared to confirm results. Cell density in the SP-treated wounds (11.3×107 cells/gram tissue, SD +/−1.5×107) was greater than in NaCl-treated wounds (7×107 cells/gram tissue, SD +/−2.3×107, p<.05) at day 7 post-wounding. Substance P significantly increased the density of leukocytes (2.1×107, SD +/−3.6×106 vs. 1.8×107, SD+/−4.9×105, p<.02) 3 days after wounding and the density of macrophages (2.9 ×107, SD+/−7.5×106 vs. 1.3×107, SD+/−1.4×106, p<.05) 7 days after wounding. There were no significant differences in endothelial cell, leukocyte or macrophage density at later time points. Topical SP treatment increases early inflammatory density in the healing wounds of db/db mice. These data support a role for nerve-mediated inflammation in cutaneous wound repair. PMID:18638272
Baudrand, R; Lian, CG; Lian, BQ; Ricchiuti, V; Yao, TM; Li, J; Williams, GH; Adler, GK
2015-01-01
Background/Aim Obesity is associated with changes in adiponectin and pro-inflammatory adipokines. Sodium intake can affect adipokine secretion suggesting a role in cardiovascular dysfunction. We tested if long-term dietary sodium restriction modifies the expression of adiponectin and ameliorates the pro-inflammatory profile of obese, diabetic Methods/Results Db/db mice were randomized to high sodium (HS 1.6% Na+, n=6) or low sodium (LS 0.03% Na+, n=8) diet for 16 weeks and compared with lean, db/+ mice on HS diet (n=8). Insulin levels were 50% lower in the db/db mice on LS diet when compared with HS db/db (p <0.05). LS diet increased cardiac adiponectin mRNA levels in db/db mice by 5-fold when compared with db/db mice on HS diet and by 2-fold when compared with HS lean mice (both p < 0.01). LS diet increased adiponectin in adipose tissue compared with db/db mice on HS diet, achieving levels similar to those of lean mice. MCP-1, IL-6 and TNF-α expression were reduced more than 50% in adipose tissue of db/db mice on LS diet when compared with HS db/db mice (all p < 0.05), to levels observed in the HS lean mice. Further, LS db/db mice had significantly reduced circulating MCP-1 and IL-6 levels when compared with HS db/db mice (both p < 0.01). Conclusion In obese-diabetic mice, long-term LS diet increases adiponectin in heart and adipose tissue and reduces pro-inflammatory factors in adipose tissue and plasma. These additive mechanisms may contribute to the potential cardioprotective benefits of LS diet in obesity-related metabolic disorders. PMID:24418377
Experimental demonstration of fiber optical parametric chirped-pulse amplification
NASA Astrophysics Data System (ADS)
Zhou, Yue; Cheung, Kim K. Y.; Chui, P. C.; Wong, Kenneth K. Y.
2010-02-01
A fiber optical parametric chirped-pulse amplifier (FOPCPA) is experimentally demonstrated. A 1.76 ps signal at 1542 nm with a peak power of 20 mW is broadened to 40 ps, and then amplified by a 100-ps pulsed pump at 1560 nm. The corresponding idler at 1578 nm is generated as the FOPCPA output. The same medium used to stretch the signal is deployed to compress the idler to 3.8 ps, and another spool of fiber is deployed to further compress the idler to 1.87 ps. The peak power of the compressed idler is 2 W, which corresponds to a gain of 20 dB.
Park, Sang-Sub
2014-01-01
The purpose of this study is to grasp difference in quality of chest compression accuracy between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method. Participants were progressed 64 people except 6 absentees among 70 people who agreed to participation with completing the CPR curriculum. In the classification of group in participants, the modified chest compression method was called as smartphone group (33 people). The standardized chest compression method was called as traditional group (31 people). The common equipments in both groups were used Manikin for practice and Manikin for evaluation. In the meantime, the smartphone group for application was utilized Android and iOS Operating System (OS) of 2 smartphone products (G, i). The measurement period was conducted from September 25th to 26th, 2012. Data analysis was used SPSS WIN 12.0 program. As a result of research, the proper compression depth (mm) was shown the proper compression depth (p< 0.01) in traditional group (53.77 mm) compared to smartphone group (48.35 mm). Even the proper chest compression (%) was formed suitably (p< 0.05) in traditional group (73.96%) more than smartphone group (60.51%). As for the awareness of chest compression accuracy, the traditional group (3.83 points) had the higher awareness of chest compression accuracy (p< 0.001) than the smartphone group (2.32 points). In the questionnaire that was additionally carried out 1 question only in smartphone group, the modified chest compression method with the use of smartphone had the high negative reason in rescuer for occurrence of hand back pain (48.5%) and unstable posture (21.2%).
Heo, Dong Won; Kim, Kyoung Nam; Lee, Min Woo; Lee, Sung Bok; Kim, Chang-Sik
2017-01-01
To evaluate the properties of pattern standard deviation (PSD) according to localization of the glaucomatous optic neuropathy. We enrolled 242 eyes of 242 patients with primary open-angle glaucoma, with a best-corrected visual acuity ≥ 20/25, and no media opacity. Patients were examined via dilated fundus photography, spectral-domain optical coherence tomography, and Humphrey visual field examination, and divided into those with hemi-optic neuropathy (superior or inferior) and bi-optic neuropathy (both superior and inferior). We assessed the relationship between mean deviation (MD) and PSD. Using broken stick regression analysis, the tipping point was identified, i.e., the point at which MD became significantly associated with a paradoxical reversal of PSD. In 91 patients with hemi-optic neuropathy, PSD showed a strong correlation with MD (r = -0.973, β = -0.965, p < 0.001). The difference between MD and PSD ("-MD-PSD") was constant (mean, -0.32 dB; 95% confidence interval, -2.48~1.84 dB) regardless of visual field defect severity. However, in 151 patients with bi-optic neuropathy, a negative correlation was evident between "-MD-PSD" and MD (r2 = 0.907, p < 0.001). Overall, the MD tipping point was -14.0 dB, which was close to approximately 50% damage of the entire visual field (p < 0.001). Although a false decrease of PSD usually begins at approximately 50% visual field damage, in patients with hemi-optic neuropathy, the PSD shows no paradoxical decrease and shows a linear correlation with MD.
Choi, Hojong; Woo, Park Chul; Yeom, Jung-Yeol; Yoon, Changhan
2017-04-04
A power MOSFET linearizer is proposed for a high-voltage power amplifier (HVPA) used in high-frequency pulse-echo instrumentation. The power MOSFET linearizer is composed of a DC bias-controlled series power MOSFET shunt with parallel inductors and capacitors. The proposed scheme is designed to improve the gain deviation characteristics of the HVPA at higher input powers. By controlling the MOSFET bias voltage in the linearizer, the gain reduction into the HVPA was compensated, thereby reducing the echo harmonic distortion components generated by the ultrasonic transducers. In order to verify the performance improvement of the HVPA implementing the power MOSFET linearizer, we measured and found that the gain deviation of the power MOSFET linearizer integrated with HVPA under 10 V DC bias voltage was reduced (-1.8 and -0.96 dB, respectively) compared to that of the HVPA without the power MOSFET linearizer (-2.95 and -3.0 dB, respectively) when 70 and 80 MHz, three-cycle, and 26 dB m input pulse waveforms are applied, respectively. The input 1-dB compression point (an index of linearity) of the HVPA with power MOSFET linearizer (24.17 and 26.19 dB m at 70 and 80 MHz, respectively) at 10 V DC bias voltage was increased compared to that of HVPA without the power MOSFET linearizer (22.03 and 22.13 dB m at 70 and 80 MHz, respectively). To further verify the reduction of the echo harmonic distortion components generated by the ultrasonic transducers, the pulse-echo responses in the pulse-echo instrumentation were compared when using HVPA with and without the power MOSFET linearizer. When three-cycle 26 dB m input power was applied, the second, third, fourth, and fifth harmonic distortion components of a 75 MHz transducer driven by the HVPA with power MOSFET linearizer (-48.34, -44.21, -48.34, and -46.56 dB, respectively) were lower than that of the HVPA without the power MOSFET linearizer (-45.61, -41.57, -45.01, and -45.51 dB, respectively). When five-cycle 20 dB m input power was applied, the second, third, fourth, and fifth harmonic distortions of the HVPA with the power MOSFET linearizer (-41.54, -41.80, -48.86, and -46.27 dB, respectively) were also lower than that of the HVPA without the power MOSFET linearizer (-25.85, -43.56, -49.04, and -49.24 dB, respectively). Therefore, we conclude that the power MOSFET linearizer could reduce gain deviation of the HVPA, thus reducing the echo signal harmonic distortions generated by the high-frequency ultrasonic transducers in pulse-echo instrumentation.
Trask, Aaron J; Delbin, Maria A; Katz, Paige S; Zanesco, Angelina; Lucchesi, Pamela A
2012-01-01
The goals of the present study were to compare coronary resistance microvessel (CRM) remodeling between type 1 diabetes mellitus (T1DM) and type 2 diabetes mellitus (T2DM) mice, and to determine the impact of aerobic exercise training on CRM remodeling in diabetes. Eight week old male mice were divided into T1DM: control sedentary (Control-SD), T1DM sedentary (T1DM-SD) induced by streptozotocin, and T1DM exercise trained (T1DM-TR); T2DM: control sedentary (Db/db-SD), T2DM sedentary (db/db-SD), and T2DM trained (db/db-TR). Aerobic exercise training (TR) was performed on a mouse treadmill for 8weeks. CRMs were isolated and mounted on a pressure myograph to measure and record vascular remodeling and mechanics. CRM diameters, wall thickness, stress-strain, incremental modulus remained unchanged in T1DM-SD mice compared to control, and exercise training showed no effect. In contrast, CRMs isolated from db/db-SD mice exhibited decreased luminal diameter with thicker microvascular walls, which significantly increased the wall:lumen ratio (Db/db-SD: 5.8±0.3 vs. db/db-SD: 8.9±0.7, p<0.001). Compared to db/db-SD mice, coronary arterioles isolated from db/db-TR mice had similar internal diameter and wall thickness, while wall:lumen ratio (6.8±0.2, p<0.05) and growth index (db/db-SD: 16.2 vs. db/db-TR: 4.3, % over Db/db) were reduced. These data show that CRMs undergo adverse inward hypertrophic remodeling only in T2DM, but not T1DM, and that aerobic exercise training can partially mitigate this process. Copyright © 2012 Elsevier Inc. All rights reserved.
Ye, Hongying; Zhang, Herbert J; Xu, Aimin; Hoo, Ruby L C
2013-01-01
This study was designed to (1) investigate the expression profiles of resistin in db/db mice and its dynamic association with metabolic parameters; and (2) evaluate the effects of Rosiglitazone on production of resistin. Db/db mice and their lean litter mates were used for this study. Epididymal fat tissue was excised from mice of different age (from 5 to 12 weeks) for ex vivo incubation. Resistin,along with adiponectin,in serum and conditioned culture medium of epididymal fat pads were measured with immunoassays. The gene expression of resistin was determined by real-time PCR. Rosiglitazone or the vehicle (PBS) was administered into db/db mice by daily intra-gastric gavage. Differentiated 3T3-L1 adipocytes were used for in vitro evaluation. The secretion of resistin from the fat pads in db/db mice was significantly lower than that in lean mice (P<0.01). The mRNA expression of the resistin gene in fat tissue of db/db mice at the age of 5 weeks was decreased by 60.5% compared to lean controls (p<0.05). Serum levels of resistin were comparable between the obese and lean groups, perhaps due to the increased total fat mass in db/db mice. Correlation analysis showed that serum resistin levels were positively correlated to resistin secretion from fat pads(r = 0.844,P = 0.000), while negatively associated with the body weight (r = -0.515, P = 0.000) and fasting glucose level (r = -0.357, P = 0.002). Notably, treatment with rosiglitazone increased the serum resistin levels by 66.4%(P<0.05)in db/db mice. In 3T3-L1 adipocytes, Rosiglitazone (10 uM) markedly enhanced the secretion of resistin by 120% (P<0.01) and its gene expression by 78.1% (P<0.05). Both resistin gene expression and its secretion from the epididymal adipose tissue were decreased in db/db obese mice, while the insulin-sensitizing drug rosiglitazone increased resistin production. Our results do not support the role of resistin as an etiological link between obesity and diabetes.
NASA Astrophysics Data System (ADS)
Han, Jiang-An; Kong, Zhi-Hui; Ma, Kaixue; Yeo, Kiat Seng; Lim, Wei Meng
2016-11-01
This paper presents a novel balun for a millimeter-wave power amplifier (PA) design to achieve high-power density in a 65-nm low-power (LP) CMOS process. By using a concentric winding technique, the proposed parallel combining balun with compact size accomplishes power combining and unbalance-balance conversion concurrently. For calculating its power combination efficiency in the condition of various amplitude and phase wave components, a method basing on S-parameters is derived. Based on the proposed parallel combining balun, a fabricated 60-GHz industrial, scientific, and medical (ISM) band PA with single-ended I/O achieves an 18.9-dB gain and an 8.8-dBm output power at 1-dB compression and 14.3-dBm saturated output power ( P sat) at 62 GHz. This PA occupying only a 0.10-mm2 core area has demonstrated a high-power density of 269.15 mW/mm2 in 65 nm LP CMOS.
Querques, Lea; Querques, Giuseppe; Forte, Raimondo; Souied, Eric H
2012-06-01
To investigate the microperimetric correlations of autofluorescence imaging and optical coherence tomography (OCT) in dry age-related macular degeneration (AMD). Retrospective, observational, cross-sectional study. Consecutive patients with dry AMD underwent a complete ophthalmologic examination, including best-corrected visual acuity (BCVA), blue fundus autofluorescence (FAF), near-infrared autofluorescence, and spectral-domain (SD)-OCT with integrated microperimetry. A total of 58 eyes of 29 patients (21 women; mean age 73 ± 9 years) were included. Mean BCVA was 0.28 ± 0.3 logarithm of the minimal angle of resolution (logMAR). Overall, 2842 points were analyzed as regards FAF and near-infrared autofluorescence patterns, the status of inner segment/outer segment (IS/OS) interface, and retinal sensitivity. We observed a good correlation between the FAF and near-infrared autofluorescence patterns for all the points graded (increased FAF/near-infrared autofluorescence, Pearson rho = 0.6, P = .02; decreased FAF/near-infrared autofluorescence, Pearson rho = 0.7, P = .01; normal FAF/near-infrared autofluorescence, Pearson rho = 0.7, P = .01). Mean retinal sensitivity was significantly reduced in cases of decreased FAF (4.73 ± 2.23 dB) or increased FAF (4.75 ± 2.39 dB) compared with normal FAF (7.44 ± 2.34 dB) (P = .001). Mean retinal sensitivity was significantly reduced in case of decreased near-infrared autofluorescence (3.87 ± 2.28 dB), compared with increased near-infrared autofluorescence (5.76 ± 2.44 dB) (P = .02); mean retinal sensitivity in case of increased near-infrared autofluorescence was significantly reduced compared with normal near-infrared autofluorescence (7.15 ± 2.38 dB) (P = .002). On SD-OCT, there was a high inverse correlation between retinal sensitivity and rate of disruptions in IS/OS interface (Pearson rho = -0.72, P = .001). A reduced retinal sensitivity consistently correlates with decreased FAF/near-infrared autofluorescence and a disrupted IS/OS interface. Increased near-infrared autofluorescence may represent a useful method for detection of retinal abnormalities early in dry AMD development. Copyright © 2012 Elsevier Inc. All rights reserved.
1992-04-13
and J. E. Bowers. - Design of density is negligible so that (I) simply gives an exponential 1.3-om GalnA&P mrface-emitang lawe for hig4andwidth opera...promising design used a dorn from 15n. requemay reepoa of the device was planar interdigitated Schotky barrier with a low-frequency charsicterzda t a CW-lur...measured detector frequency response. device designs , p-i-n [1], [2], vertical Schottky barrier [3], This model gives a 24-GHz 3-dB point for the present
Central Field Index Versus Visual Field Index for Central Visual Function in Stable Glaucoma.
Rao, Aparna; Padhy, Debananda; Mudunuri, Harika; Roy, Avik K; Sarangi, Sarada P; Das, Gopinath
2017-01-01
To compare the variability of central field index (CFI) versus visual field index (VFI) in stable glaucoma with central fixation involvement. For this retrospective study, we identified multiple visual fields (VFs) of patients with repeatable central fixation involvement on Humphrey VFs (24-2 and 10-2 program) which were stable (clinically and on VFs) over a very short period of 2 to 3 months. The VFI and CFI were calculated as described in earlier reports. We graded the fields as early [mean deviation (MD)>-6 dB], moderate (-6.1 to -12 dB), and severe glaucoma (<-12 dB) based on MD on 24-2 program. The variability of CFI and VFI between visits and across different severity of glaucoma was compared. Relation of the divergence to field indices and clinical parameters were assessed. The intervisit difference for VFI was greater than CFI ranging from -4% to 9% versus -1% to 8% in early (P=0.9), -13% to 18% versus -6% to 17% (P=0.056) in moderate, and -21% to 19% versus -9% to 9% (P<0.001) in severe glaucoma. The CFI within each group had narrower range than VFI with maximum range in severe glaucoma (33% to 95%). The divergence of CFI from VFI started at MD 24-2 beyond (worse) -10 dB. This difference between CFI and VFI was associated significantly with number of points with P<1% on 24-2 (R=80.3%). CFI is less variable than VFI in stable eyes with fixation involvement especially in severe glaucoma indicating need for incorporating CFI calculation for monitoring advanced disease in eyes with central defects.
Casas, F J; Pascual, J P; de la Fuente, M L; Artal, E; Portilla, J
2010-07-01
This paper describes a comparative nonlinear analysis of low-noise amplifiers (LNAs) under different stimuli for use in astronomical applications. Wide-band Gaussian-noise input signals, together with the high values of gain required, make that figures of merit, such as the 1 dB compression (1 dBc) point of amplifiers, become crucial in the design process of radiometric receivers in order to guarantee the linearity in their nominal operation. The typical method to obtain the 1 dBc point is by using single-tone excitation signals to get the nonlinear amplitude to amplitude (AM-AM) characteristic but, as will be shown in the paper, in radiometers, the nature of the wide-band Gaussian-noise excitation signals makes the amplifiers present higher nonlinearity than when using single tone excitation signals. Therefore, in order to analyze the suitability of the LNA's nominal operation, the 1 dBc point has to be obtained, but using realistic excitation signals. In this work, an analytical study of compression effects in amplifiers due to excitation signals composed of several tones is reported. Moreover, LNA nonlinear characteristics, as AM-AM, total distortion, and power to distortion ratio, have been obtained by simulation and measurement with wide-band Gaussian-noise excitation signals. This kind of signal can be considered as a limit case of a multitone signal, when the number of tones is very high. The work is illustrated by means of the extraction of realistic nonlinear characteristics, through simulation and measurement, of a 31 GHz back-end module LNA used in the radiometer of the QUIJOTE (Q U I JOint TEnerife) CMB experiment.
NASA Astrophysics Data System (ADS)
Nguyen, Thu-Mai; Song, Shaozhen; Arnal, Bastien; Wong, Emily Y.; Shen, Tueng T.; Wang, Ruikang K.; O'Donnell, Matthew
2015-03-01
Tissue stiffness can be measured from the propagation speed of shear waves. Acoustic radiation force (ARF) can generate shear waves by focusing ultrasound in tissue for ~100 μs. Safety considerations and electronics abilities limit ultrasound pressures. We previously presented shear wave elastography combining ARF and phase-sensitive optical coherence tomography (PhS-OCT) [1]. Here, we use amplitude-modulated ARF to enhance shear wave signal-to-noise ratio (SNR) at low pressures. Experiments were performed on tissue-mimicking phantoms. ARF was applied using a single-element transducer, driven by a 7.5 MHz, 3-ms, sine wave modulated in amplitude by a linear-swept frequency (1 to 7 kHz). Pressures between 1 to 3 MPa were tested. Displacements were tracked using PhS-OCT and numerically compressed using pulse compression methods detailed in previous work [2]. SNR was compared to that of 200-μs bursts. Stiffness maps were reconstructed using time-of-flight computations. 200-μs bursts give barely detectable displacements at 1 MPa (3.7 dB SNR). Pulse compression gives 36.2 dB at 1.5 MPa. In all cases with detectable displacements, shear wave speeds were determined in 5%-gelatin and 10%-gelatin phantoms and compared to literature values. Applicability to ocular tissues (cornea, intraocular lens) is under investigation.
[Auditory evoked potential and personality traits in chronic primary insomniacs].
Shen, Jian; Shui, Ren-de; Feng, Lei; Liu, Yu-Hong; He, Wei; Huang, Jing-Yi; Wang, Wei
2009-05-01
To investigate the personality traits and intensity dependence of auditory evoked potentials (AEPs) in chronic primary insomnia. Thirty-seven patients with chronic primary insomnia (insomnia group) and 44 healthy subjects (control group) were enrolled in the study. The AEPs were examined in insomnia and control groups; the personality traits were studied by Zuckerman's Sensation Seeking Scales (SSS) and Zuckerman-Kuhlman's Personality Questionnaire (ZKPQ); and the mood states by Plutchik-van Praag's Depression Inventory (PVP). The scores of neuroticism-anxiety and depression in insomnia group were significantly higher than those in control group (P<0.01); and the scores of impulsivity and aggression-hostility were also higher than those in control group (P<0.05); N1-P2 amplitude of AEP increased with stimulus intensity, which were significantly different in 70, 80, 90,100 dB (P<0.01). There were significant correlations between activity and N1 latency at 80 dB, activity and P2 latency at 100 dB (r=0.270, r=0.276, P<0.05); and between total scores of sensation seeking scale and N1-P2 amplitude (r=0.3746, r=0.35329, P<0.01) at 70 and 90 dB stimulus intensity in insomnia group. There were significant correlations among experience seeking and N1-P2 amplitude, experience seeking and slope rate (P<0.01) at 70, 80, 90, 100 dB stimulus intensity in insomnia group (r=0.539, r=0.3439, r=0.439, r=0.3278). There were significant correlations between sensation seeking of boredom susceptibility and slope rate (r=-0.282998, P<0.05) in insomnia group. There were significant correlations between thrill and adventure seeking and N1-P2 amplitude(r=0.2789, P<0.05) at 90 dB stimulus intensity in insomnia group; there were significant correlations between PVP and N1-P2 amplitude (r=-0.3434, r=-0.3158, P<0.05) at 70 dB and N1 latency at 80 dB in insomnia group. Chronic primary insomnia sufferers have higher levels of neuroticism-anxiety, depression, aggression-hostility and impulsivity, and some are correlated with stimulus intensity dependence in AEP.
Trial of Continuous or Interrupted Chest Compressions during CPR.
Nichol, Graham; Leroux, Brian; Wang, Henry; Callaway, Clifton W; Sopko, George; Weisfeldt, Myron; Stiell, Ian; Morrison, Laurie J; Aufderheide, Tom P; Cheskes, Sheldon; Christenson, Jim; Kudenchuk, Peter; Vaillancourt, Christian; Rea, Thomas D; Idris, Ahamed H; Colella, Riccardo; Isaacs, Marshal; Straight, Ron; Stephens, Shannon; Richardson, Joe; Condle, Joe; Schmicker, Robert H; Egan, Debra; May, Susanne; Ornato, Joseph P
2015-12-03
During cardiopulmonary resuscitation (CPR) in patients with out-of-hospital cardiac arrest, the interruption of manual chest compressions for rescue breathing reduces blood flow and possibly survival. We assessed whether outcomes after continuous compressions with positive-pressure ventilation differed from those after compressions that were interrupted for ventilations at a ratio of 30 compressions to two ventilations. This cluster-randomized trial with crossover included 114 emergency medical service (EMS) agencies. Adults with non-trauma-related cardiac arrest who were treated by EMS providers received continuous chest compressions (intervention group) or interrupted chest compressions (control group). The primary outcome was the rate of survival to hospital discharge. Secondary outcomes included the modified Rankin scale score (on a scale from 0 to 6, with a score of ≤3 indicating favorable neurologic function). CPR process was measured to assess compliance. Of 23,711 patients included in the primary analysis, 12,653 were assigned to the intervention group and 11,058 to the control group. A total of 1129 of 12,613 patients with available data (9.0%) in the intervention group and 1072 of 11,035 with available data (9.7%) in the control group survived until discharge (difference, -0.7 percentage points; 95% confidence interval [CI], -1.5 to 0.1; P=0.07); 7.0% of the patients in the intervention group and 7.7% of those in the control group survived with favorable neurologic function at discharge (difference, -0.6 percentage points; 95% CI, -1.4 to 0.1, P=0.09). Hospital-free survival was significantly shorter in the intervention group than in the control group (mean difference, -0.2 days; 95% CI, -0.3 to -0.1; P=0.004). In patients with out-of-hospital cardiac arrest, continuous chest compressions during CPR performed by EMS providers did not result in significantly higher rates of survival or favorable neurologic function than did interrupted chest compressions. (Funded by the National Heart, Lung, and Blood Institute and others; ROC CCC ClinicalTrials.gov number, NCT01372748.).
Phase transition studies of Na3Bi system under uniaxial strain
NASA Astrophysics Data System (ADS)
Nie, Tiaoping; Meng, Lijun; Li, Yanru; Luan, Yanhua; Yu, Jun
2018-03-01
We investigated the electronic properties and phase transitions of Na3Bi in four structural phases (space groups P63/mmc, P \\overline{3} c1, Fm \\overline{3} m and Cmcm) under constant-volume uniaxial strain using the first-principles method. For P63/mmc and P \\overline{3} c1-Na3Bi, an important phase transition from a topological Dirac semimetal (TDS) to a topological insulator appears under compression strain around 4.5%. The insulating gap increases with the increasing compressive strain and up to around 0.1 eV at a strain of 10%. However, both P63/mmc and P \\overline{3} c1-Na3Bi still keep the properties of a TDS within a tensile strain of 0-10%, although the Dirac points move away from the Γ point along Γ-A in reciprocal space as the tensile strain increases. The Na3Bi with space group Fm \\overline{3} m is identified as a topological semimetal with the inverted bands between Na-3s and Bi-6p and a parabolic dispersion in the vicinity of Γ point. Interestingly, for Fm \\overline{3} m-Na3Bi, both compression and tensile strain lead to a TDS which is identified by calculating surface Fermi arcs and topological invariants at time-reversal planes (k z = 0 and k z = π/c) in reciprocal space. Additionally, we confirmed the high pressure phase Cmcm-Na3Bi is an ordinary insulator with a gap of about 0.62 eV. It is noteworthy that its gap almost keeps constant around 0.60 eV within a compression strain of 0-10%. In contrast, a remarkable phase transition from an insulator to a metal phase appears under tensile strain. Moreover, this phase transition is highly sensitive to tensile strain and takes place only at a strain 1.0%. These strain-induced electronic structures and phase transitions of the Na3Bi system in various phases are important due to their possible applications under high pressure in future electronic devices.
NASA Astrophysics Data System (ADS)
Babichev, A. V.; Karachinsky, L. Ya.; Novikov, I. I.; Gladyshev, A. G.; Mikhailov, S.; Iakovlev, V.; Sirbu, A.; Stepniak, G.; Chorchos, L.; Turkiewicz, J. P.; Agustin, M.; Ledentsov, N. N.; Voropaev, K. O.; Ionov, A. S.; Egorov, A. Yu.
2017-02-01
We report for the first time on wafer-fused InGaAs-InP/AlGaAs-GaAs 1550 nm vertical-cavity surface-emitting lasers (VCSELs) incorporating a InAlGaAs/InP MQW active region with re-grown tunnel junction sandwiched between top and bottom undoped AlGaAs/GaAs distributed Bragg reflectors (DBRs) all grown by molecular beam epitaxy. InP-based active region includes seven compressively strained quantum wells (2.8 nm) optimized to provide high differential gain. Devices with this active region demonstrate lasing threshold current < 2.5 mA and output optical power > 2 mW in the temperature range of 10-70°C. The wall-plug efficiency (WPE) value-reaches 20 %. Lasing spectra show single mode CW operation with a longitudinal side mode suppression ratio (SMSR) up to 45 dB at > 2 mW output power. Small signal modulation response measurements show a 3-dB modulation bandwidth of 9 GHz at pump current of 10 mA and a D-factor value of 3 GHz/(mA)1/2. Open-eye diagram at 30 Gb/s of standard NRZ is demonstrated. Achieved CW and modulation performance is quite sufficient for fiber to the home (FTTH) applications where very large volumes of low-cost lasers are required.
Metabolic characterization of a mouse deficient in all known leptin receptor isoforms.
Osborn, Olivia; Sanchez-Alavez, Manuel; Brownell, Sara E; Ross, Brendon; Klaus, Joe; Dubins, Jeffrey; Beutler, Bruce; Conti, Bruno; Bartfai, Tamas
2010-01-01
We have characterized a newly generated mouse model of obesity, a mouse strain deficient in all five previously described leptin receptor isoforms. These transgenic mice, named the db (333)/db (333) mice, were identified from an ENU mutagenesis screen and carry a point mutation in the seventh exon of the db gene encoding the leptin receptor, resulting in a premature stop codon (Y(333)Stop) and gene product that lacks STAT signaling domains. db (333)/db (333) mice have a morbidly obese phenotype, with body weights diverging from wild type as early as 4 weeks of age (P < 0.05). To determine the contribution of the short isoforms of the leptin receptor in this metabolic phenotype, we performed an extensive metabolic characterization of the db (333)/db (333) mouse in relation to the well-characterized db/db mouse lacking only the long form of the leptin receptor. db (333)/db (333) mice have similar endocrine and metabolic parameters as previously described in other leptin receptor transgenic mice including db/db mice that lack only the long isoform of the leptin receptor. However, db (333)/db (333) mice show a subtle trend toward higher body weight and insulin levels, lower oxygen, carbon dioxide production, respiratory exchange ratio (RER), and temperature than db/db mice suggesting the short isoforms may play an additional role in energy homeostasis.
Barboni, Mirella Telles Salgueiro; Szepessy, Zsuzsanna; Ventura, Dora Fix; Németh, János
2018-04-01
To establish fluctuation limits, it was considered that not only overall macular sensitivity but also fluctuations of individual test points in the macula might have clinical value. Three repeated measurements of microperimetry were performed using the Standard Expert test of Macular Integrity Assessment (MAIA) in healthy subjects ( N = 12, age = 23.8 ± 1.5 years old) and in patients with age-related macular degeneration (AMD) ( N = 11, age = 68.5 ± 7.4 years old). A total of 37 macular points arranged in four concentric rings and in four quadrants were analyzed individually and in groups. The data show low fluctuation of macular sensitivity of individual test points in healthy subjects (average = 1.38 ± 0.28 dB) and AMD patients (average = 2.12 ± 0.60 dB). Lower sensitivity points are more related to higher fluctuation than to the distance from the central point. Fixation stability showed no effect on the sensitivity fluctuation. The 95th percentile of the standard deviations of healthy subjects was, on average, 2.7 dB, ranging from 1.2 to 4 dB, depending on the point tested. Point analysis and regional analysis might be considered prior to evaluating macular sensitivity fluctuation in order to distinguish between normal variation and a clinical change. S tatistical methods were used to compare repeated microperimetry measurements and to establish fluctuation limits of the macular sensitivity. This analysis could add information regarding the integrity of different macular areas and provide new insights into fixation points prior to the biofeedback fixation training.
Walder, B; Francioli, D; Meyer, J J; Lançon, M; Romand, J A
2000-07-01
Because of around-the-clock activities, environmental noise and light are among the many causes of sleep disturbance in an intensive care unit (ICU). The implementation of guidelines may potentially change behavior rules and improve sleep quality. A prospective interventional study, observing the effects of simple nighttime guidelines on light and noise levels in an ICU. A modern surgical ICU, subdivided into six identical three-bed rooms. Critically ill adult patients. Between two observation periods, five guidelines were implemented to decrease both light and noise during the night shift in the patient's room. Light levels and noise levels were obtained using a luxmeter and a sound level meter [A-weighted decibels (dB) scale] and were monitored continuously from 11 pm to 5 am both before (period P1) and after (period P2) the implementation of guidelines. Similar patient's gravity and nursing workload scores were observed between P1 and P2. A low mean (<5 Lux) and maximal light level were measured during both P1 and P2. The implementation of guidelines lowered mean light disturbance intensity with a greater variability of light during P2. All noise levels were high and corresponded more to a quiet office for noise level equivalents and to a busy restaurant for peak noise levels during both P1 and P2. Guidelines decreased the noise level equivalent (P1, 51.3 dB; P2, 48.3 dB), peak noise level (P1, 74.9 dB; P2, 70.8 dB), and the number of acoustic identified alarms (P1, 22.1 dB; P2, 15.8 dB) during P2. The night light levels were low during both periods, and lowering the light levels induced a greater variation of light, which may impair sleep quality. All measured noise levels were high during both periods, which could contribute to sleep disturbance, and the implementation of guidelines significantly lowers some important noise levels. The background noise level was unchanged.
Vishwakarma, R K; Shivhare, U S; Nanda, S K
2012-09-01
Hertz's theory of contact stresses was applied to predict the splitting of guar seeds during uni-axial compressive loading between 2 rigid parallel plates. The apparent modulus of elasticity of guar seeds varied between 296.18 and 116.19 MPa when force was applied normal to hilum joint (horizontal position), whereas it varied between 171.86 and 54.18 MPa when force was applied in the direction of hilum joint (vertical position) with in moisture content range of 5.16% to 15.28% (d.b.). At higher moisture contents, the seeds yielded after considerable deformation, thus showing ductile nature. Distribution of stresses below the point of contact were plotted to predict the location of critical point, which was found at 0.44 to 0.64 mm and 0.37 to 0.53 mm below the contact point in vertical and horizontal loading, respectively, depending upon moisture content. The separation of cotyledons from each other initiated before yielding of cotyledons and thus splitting of seed took place. The relationships between apparent modulus of elasticity, principal stresses with moisture content were described using second-order polynomial equations and validated experimentally. Manufacture of guar gum powder requires dehulling and splitting of guar seeds. This article describes splitting behavior of guar seeds under compressive loading. Results of this study may be used for design of dehulling and splitting systems of guar seeds. © 2012 Institute of Food Technologists®
Rasmussen, Stinne Eika; Nebsbjerg, Mette Amalie; Krogh, Lise Qvirin; Bjørnshave, Katrine; Krogh, Kristian; Povlsen, Jonas Agerlund; Riddervold, Ingunn Skogstad; Grøfte, Thorbjørn; Kirkegaard, Hans; Løfgren, Bo
2017-01-01
Emergency dispatchers use protocols to instruct bystanders in cardiopulmonary resuscitation (CPR). Studies changing one element in the dispatcher's protocol report improved CPR quality. Whether several changes interact is unknown and the effect of combining multiple changes previously reported to improve CPR quality into one protocol remains to be investigated. We hypothesize that a novel dispatch protocol, combining multiple beneficial elements improves CPR quality compared with a standard protocol. A novel dispatch protocol was designed including wording on chest compressions, using a metronome, regular encouragements and a 10-s rest each minute. In a simulated cardiac arrest scenario, laypersons were randomized to perform single-rescuer CPR guided with the novel or the standard protocol. a composite endpoint of time to first compression, hand position, compression depth and rate and hands-off time (maximum score: 22 points). Afterwards participants answered a questionnaire evaluating the dispatcher assistance. The novel protocol (n=61) improved CPR quality score compared with the standard protocol (n=64) (mean (SD): 18.6 (1.4)) points vs. 17.5 (1.7) points, p<0.001. The novel protocol resulted in deeper chest compressions (mean (SD): 58 (12)mm vs. 52 (13)mm, p=0.02) and improved rate of correct hand position (61% vs. 36%, p=0.01) compared with the standard protocol. In both protocols hands-off time was short. The novel protocol improved motivation among rescuers compared with the standard protocol (p=0.002). Participants guided with a standard dispatch protocol performed high quality CPR. A novel bundle of care protocol improved CPR quality score and motivation among rescuers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
The comparative genotoxic effects of racemic trans-8,9dihydroxy-8,9-dihydrodibenzo[a,l]pyrene (trans- DB[a,l]P8,9-diol), the metabolic K-region dihydrodiol of dibenzo[a,l] pyrene (DB[a,l]P) (dibenzo[def,p]chrysene) and DB[a,l]P in transformable mouse embryo C3HIOT1/2C18 (C3HIOT1/...
Behavior of visual field index in advanced glaucoma.
Rao, Harsha L; Senthil, Sirisha; Choudhari, Nikhil S; Mandal, Anil K; Garudadri, Chandra S
2013-01-14
To evaluate the magnitude of Visual Field Index (VFI) change attributable to change in the estimation algorithm from the pattern deviation probability plot (PDPP) to the total deviation probability plot (TDPP) when the mean deviation (MD) crosses -20 decibels (dB). In a retrospective study, 37 stable glaucoma eyes in which MD of the VFs crossed -20 dB were identified. For each eye, a pair of VFs was selected so that one VF of the pair had a MD better than but close to -20 dB and the other had a MD worse than but again close to -20 dB. The change in VFI in the VF pairs and its associations with the number of points in probability plots with normal threshold sensitivities were evaluated. Similar pairs of VFs from 28 stable glaucoma eyes where the MD crossed -10 dB were chosen as controls. The change in VFI in VF pairs when the MD crossed 20 dB ranged from 3% to 33% (median: 15%), while the change when MD crossed -10 dB ranged from 1% to 8% (median: 4%). Difference in the number of points with normal threshold sensitivities in PDPP when MD was better than -20 dB compared to those in TDPP when MD crossed -20 dB significantly influenced the VFI change (R(2) = 0.65). Considering the eccentricity of these points further explained the VFI change (R(2) = 0.81). The decrease in VFI when MD crosses -20 dB can be highly variable. This has to be considered with the use of VFI in clinical and research settings.
The Words-in-Noise Test (WIN), list 3: a practice list.
Wilson, Richard H; Watts, Kelly L
2012-02-01
The Words-in-Noise Test (WIN) was developed as an instrument to quantify the ability of listeners to understand monosyllabic words in background noise using multitalker babble (Wilson, 2003). The 50% point, which is calculated with the Spearman-Kärber equation (Finney, 1952), is used as the evaluative metric with the WIN materials. Initially, the WIN was designed as a 70-word instrument that presented ten unique words at each of seven signal-to-noise ratios from 24 to 0 dB in 4 dB decrements. Subsequently, the 70-word list was parsed into two 35-word lists that achieved equivalent recognition performances (Wilson and Burks, 2005). This report involves the development of a third list (WIN List 3) that was developed to serve as a practice list to familiarize the participant with listening to words presented in background babble. To determine-on young listeners with normal hearing and on older listeners with sensorineural hearing loss-the psychometric properties of the WIN List 3 materials. A quasi-experimental, repeated-measures design was used. Twenty-four young adult listeners (M = 21.6 yr) with normal pure-tone thresholds (≤ 20 dB HL at 250 to 8000 Hz) and 24 older listeners (M = 65.9 yr) with sensorineural hearing loss participated. The level of the babble was fixed at 80 dB SPL with the level of the words varied from 104 to 80 dB SPL in 4 dB decrements. For listeners with normal hearing, the 50% points for Lists 1 and 2 were similar (4.3 and 5.1 dB S/N, respectively), both of which were lower than the 50% point for List 3 (7.4 dB S/N). A similar relation was observed with the listeners with hearing loss, 50% points for Lists 1 and 2 of 12.2 and 12.4 dB S/N, respectively, compared to 15.8 dB S/N for List 3. The differences between Lists 1 and 2 and List 3 were significant. The relations among the psychometric functions and the relations among the individual data both reflected these differences. The significant ∼3 dB difference between performances on WIN Lists 1 and 2 and on WIN List 3 by the listeners with normal hearing and the listeners with hearing loss dictates caution with the use of List 3. The use of WIN List 3 should be reserved for ancillary purposes in which equivalent recognition performances are not required, for example, as a practice list or a stand alone measure. American Academy of Audiology.
40 Gbit/s low-loss silicon optical modulator based on a pipin diode.
Ziebell, Melissa; Marris-Morini, Delphine; Rasigade, Gilles; Fédéli, Jean-Marc; Crozat, Paul; Cassan, Eric; Bouville, David; Vivien, Laurent
2012-05-07
40 Gbit/s low-loss silicon optical modulators are demonstrated. The devices are based on the carrier depletion effect in a pipin diode to generate a good compromise between high efficiency, speed and low optical loss. The diode is embedded in a Mach-Zehnder interferometer, and a self-aligned fabrication process was used to obtain precise localization of the active p-doped region in the middle of the waveguide. Using a 4.7 mm (resp. 0.95 mm) long phase shifter, the modulator exhibits an extinction ratio of 6.6 dB (resp. 3.2 dB), simultaneously with an optical loss of 6 dB (resp. 4.5 dB) at the same operating point.
Design and Evaluation of a Personal Diffusion Battery.
Vosburgh, Donna J H; Klein, Timothy; Sheehan, Maura; Anthony, T Renee; Peters, Thomas M
A four-stage personal diffusion battery (pDB) was designed and constructed to measure submicron particle size distributions. The pDB consisted of a screen-type diffusion battery, solenoid valve system, and electronic controller. A data inversion spreadsheet was created to solve for the number median diameter (NMD), geometric standard deviation (GSD), and particle number concentration of unimodal aerosols using stage number concentrations from the pDB combined with a handheld condensation particle counter (pDB+CPC). The inversion spreadsheet included particle entry losses, theoretical penetrations across screens, the detection efficiency of the CPC, and constraints so the spreadsheet solved to values within the pDB range. Size distribution parameters (NMD, GSD, and number concentration) measured with the pDB+CPC with inversion spreadsheet were within 25% of those measured with a scanning mobility particle sizer (SMPS) for 5 of 12 polydisperse combustion aerosols. For three tests conducted with propylene torch exhaust, the pDB+CPC with inversion spreadsheet successfully identified that the NMD was smaller than the constraint value of 16 nm. The ratio of the nanoparticle portion of the aerosol compared to the reference ( R nano ) was calculated to determine the ability of pDB+CPC with inversion spreadsheet to measure the nanoparticle portion of the aerosols. The R nano ranged from 0.87 to 1.01 when the inversion solved and from 0.06 to 2.01 when the inversion solved to a constraint. The pDB combined with CPC has limited use as a personal monitor but combining the pDB with a different detector would allow for the pDB to be used as a personal monitor.
Design and Evaluation of a Personal Diffusion Battery
Vosburgh, Donna J. H.; Klein, Timothy; Sheehan, Maura; Anthony, T. Renee; Peters, Thomas M.
2016-01-01
A four-stage personal diffusion battery (pDB) was designed and constructed to measure submicron particle size distributions. The pDB consisted of a screen-type diffusion battery, solenoid valve system, and electronic controller. A data inversion spreadsheet was created to solve for the number median diameter (NMD), geometric standard deviation (GSD), and particle number concentration of unimodal aerosols using stage number concentrations from the pDB combined with a handheld condensation particle counter (pDB+CPC). The inversion spreadsheet included particle entry losses, theoretical penetrations across screens, the detection efficiency of the CPC, and constraints so the spreadsheet solved to values within the pDB range. Size distribution parameters (NMD, GSD, and number concentration) measured with the pDB+CPC with inversion spreadsheet were within 25% of those measured with a scanning mobility particle sizer (SMPS) for 5 of 12 polydisperse combustion aerosols. For three tests conducted with propylene torch exhaust, the pDB+CPC with inversion spreadsheet successfully identified that the NMD was smaller than the constraint value of 16 nm. The ratio of the nanoparticle portion of the aerosol compared to the reference (R nano) was calculated to determine the ability of pDB+CPC with inversion spreadsheet to measure the nanoparticle portion of the aerosols. The R nano ranged from 0.87 to 1.01 when the inversion solved and from 0.06 to 2.01 when the inversion solved to a constraint. The pDB combined with CPC has limited use as a personal monitor but combining the pDB with a different detector would allow for the pDB to be used as a personal monitor. PMID:26900207
Compression techniques in tele-radiology
NASA Astrophysics Data System (ADS)
Lu, Tianyu; Xiong, Zixiang; Yun, David Y.
1999-10-01
This paper describes a prototype telemedicine system for remote 3D radiation treatment planning. Due to voluminous medical image data and image streams generated in interactive frame rate involved in the application, the importance of deploying adjustable lossy to lossless compression techniques is emphasized in order to achieve acceptable performance via various kinds of communication networks. In particular, the compression of the data substantially reduces the transmission time and therefore allows large-scale radiation distribution simulation and interactive volume visualization using remote supercomputing resources in a timely fashion. The compression algorithms currently used in the software we developed are JPEG and H.263 lossy methods and Lempel-Ziv (LZ77) lossless methods. Both objective and subjective assessment of the effect of lossy compression methods on the volume data are conducted. Favorable results are obtained showing that substantial compression ratio is achievable within distortion tolerance. From our experience, we conclude that 30dB (PSNR) is about the lower bound to achieve acceptable quality when applying lossy compression to anatomy volume data (e.g. CT). For computer simulated data, much higher PSNR (up to 100dB) is expectable. This work not only introduces such novel approach for delivering medical services that will have significant impact on the existing cooperative image-based services, but also provides a platform for the physicians to assess the effects of lossy compression techniques on the diagnostic and aesthetic appearance of medical imaging.
Tan, Rose S; Guymer, Robyn H; Luu, Chi D
2018-05-01
To determine the intrasession and intersession test-retest repeatability of retinal sensitivity measurements using a dark-adapted chromatic perimeter (DACP). For intrasession testing, retinal sensitivity within the central 24° for the 505-nm stimulus was measured after 20, 30, and 40 minutes of dark adaptation (DA) and for the 625-nm stimulus was measured after the first and second 505-nm tests. For intersession testing, retinal sensitivity for both stimuli was measured after 30 minutes of DA at baseline and 1 month. The point-wise sensitivity (PWS) difference and coefficient of repeatability (CoR) of each stimulus and group were determined. For intrasession testing, 10 age-related macular degeneration (AMD) and eight control subjects were recruited. The overall CoR for the 505-nm stimulus was 8.4 dB for control subjects and 9.1 dB for AMD cases, and for the 625-nm stimulus was 6.7 dB for control subjects and 9.5 dB for AMD cases. For intersession testing, seven AMD cases and 13 control subjects returned an overall CoR for the 505-nm stimulus of 8.2 dB for the control and 11.7 dB for the AMD group. For the 625-nm stimulus the CoR was 6.2 dB for the control group and 8.4 dB for the AMD group. Approximately 80% of all test points had a PWS difference of ±5 dB between the two intrasession or intersession measurements for both stimuli. The CoR for the DACP is larger than that reported for scotopic perimeters; however, the majority of test points had a PWS difference of ±5 dB between tests. The DACP offers an opportunity to measure static and dynamic rod function at multiple locations with an acceptable reproducibility level.
Tamrakar, Akhilesh K; Yadav, Prem P; Tiwari, Priti; Maurya, Rakesh; Srivastava, Arvind K
2008-08-13
To identify pongamol and karanjin as lead compounds with antihyperglycemic activity from Pongamia pinnata fruits. Streptozotocin-induced diabetic rats and hyperglycemic, hyperlipidemic and hyperinsulinemic db/db mice were used to investigate the antihyperglycemic activity of pongamol and karangin isolated from the fruits of Pongamia pinnata. In streptozotocin-induced diabetic rats, single dose treatment of pongamol and karanjin lowered the blood glucose level by 12.8% (p<0.05) and 11.7% (p<0.05) at 50mg /kg dose and 22.0% (p<0.01) and 20.7% (p<0.01) at 100mg/kg dose, respectively after 6h post-oral administration. The compounds also significantly lowered blood glucose level in db/db mice with percent activity of 35.7 (p<0.01) and 30.6 (p<0.01), respectively at 100mg/kg dose after consecutive treatment for 10 days. The compounds were observed to exert a significant inhibitory effect on enzyme protein tyrosine phosphatase-1B (EC 3.1.3.48). The results showed that pongamol and karangin isolated from the fruits of Pongamia pinnata possesses significant antihyperglycemic activity in Streptozotocin-induced diabetic rats and type 2 diabetic db/db mice and protein tyrosine phosphatase-1B may be the possible target for their activity.
Hydrostatic weighing without head submersion: description of a method.
Donnelly, J E; Brown, T E; Israel, R G; Smith-Sintek, S; O'Brien, K F; Caslavka, B
1988-02-01
Hydrostatic weighing (HW) was performed at residual volume (RV) and total lung capacity without head submersion (TLCNS). Ninety-five males (25.6 +/- 4.9 yr) and 87 females (22.6 +/- 5.2 yr) were studied at two laboratory sites using identical protocols. Twenty males and 20 females were separated from the original group and randomly assigned to cross-validation groups. RVs were determined by the oxygen dilution method. Vital capacity was determined with the subject submerged in water to the shoulders. Underwater weight was determined using 10 trials at RV and 5 trials at TLCNS, with the order of methods randomly assigned. Regression analysis provided an equation to predict body density (pDb) at RV from body density (Db) at TLCNS. The equation for males was pDb (HW at RV) = 0.5829 (DbHW at TLCNS) + 0.4059, r = 0.88, SEE = 0.0067. The equation for females was pDb (HW at RV) = 0.4745 (DbHW at TLCNS) + 0.5173, r = 0.85, SEE = 0.0061. Cross-validation showed no significant differences using Db from HW at RV (males = 1.0626 g.ml-1, females = 1.0493 g.ml-1 and pDb from HW at TLCNS (males = 1.0625 g.ml-1, females = 1.0479 g.ml-1). The correlation coefficient SEE and total error for males were r = 0.95, 0.0043, and 0.0041, respectively and for females r = 0.82, 0.0084, and 0.0085, respectively. Mean percent fat for RV and TLCNS was identical for males and differed by 0.7% for females. Test-re-test data indicated the TLCNS procedure was reliable (r = 0.98).(ABSTRACT TRUNCATED AT 250 WORDS)
Basha, Tamer A; Tang, Maxine C; Tsao, Connie; Tschabrunn, Cory M; Anter, Elad; Manning, Warren J; Nezafat, Reza
2018-01-01
To develop a dark blood-late gadolinium enhancement (DB-LGE) sequence that improves scar-blood contrast and delineation of scar region. The DB-LGE sequence uses an inversion pulse followed by T 2 magnetization preparation to suppress blood and normal myocardium. Time delays inserted after preparation pulses and T 2 -magnetization-prep duration are used to adjust tissue contrast. Selection of these parameters was optimized using numerical simulations and phantom experiments. We evaluated DB-LGE in 9 swine and 42 patients (56 ± 14 years, 33 male). Improvement in scar-blood contrast and overall image quality was subjectively evaluated by two independent readers (1 = poor, 4 = excellent). The signal ratios among scar, blood, and myocardium were compared. Simulations and phantom studies demonstrated that simultaneous nulling of myocardium and blood can be achieved by selecting appropriate timing parameters. The scar-blood contrast score was significantly higher for DB-LGE (P < 0.001) with no significant difference in overall image quality (P > 0.05). Scar-blood signal ratios for DB-LGE versus LGE were 5.0 ± 2.8 versus 1.5 ± 0.5 (P < 0.001) for patients, and 2.2 ± 0.7 versus 1.0 ± 0.4 (P = 0.0023) for animals. Scar-myocardium signal ratios were 5.7 ± 2.9 versus 6.3 ± 2.6 (P = 0.35) for patients, and 3.7 ± 1.1 versus 4.1 ± 2.0 (P = 0.60) for swine. The DB-LGE sequence simultaneously reduces normal myocardium and blood signal intensity, thereby enhancing scar-blood contrast while preserving scar-myocardium contrast. Magn Reson Med 79:351-360, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Chunling, Ji; Hourong, Zhou; Xiulin, Yang; Qian, Zhang; Yuhui, Yuan; Jia, Huang
2015-12-01
To study the protective effect of erythropoietin (EPO) on brain tissue with cardiac arrest-cardiopulmonary resuscitation (CA-CPR) and its mechanism. 120 male Sprague-Dawley (SD) rats were randomly divided into three groups (each n = 40), namely: sham group, routine chest compression group, and conventional chest compression + EPO group (EPO group). The rats in each group were subdivided into CA and 6, 12, 24, 48 hours after restoration of spontaneous circulation (ROSC) five subgroups (each n = 8). The model of CA was reproduced according to the Hendrickx classical asphyxia method followed by routine chest compression, and the rats in sham group only underwent anesthesia, tracheostomy intubation and venous-puncture without asphyxia and CPR. The rats in EPO group were given the routine chest compression + EPO 5 kU/kg (2 mL/kg) after CA. Blood sample was collected at different time points of intervention for the determination the content of serum S100 β protein by enzyme linked immunosorbent assay (ELISA). All the rats were sacrificed at the corresponding time points, and the hippocampus was harvested for the calculation of the number of S100 β protein positive cells, and to examine the pathological changes and their scores at 24 hours after ROSC by light microscopy. With prolongation of ROSC time, the serum levels of S100 β protein (µg/L) in the routine chose compression group and the EPO group were significantly elevated, peaking at 24 hours (compared with CA: 305.7 ± 29.2 vs. 44.4 ± 6.2 in routine chest compression group, and 276.7 ± 28.9 vs. 44.7 ± 5.6 in the EPO group, both P < 0.05), followed by a fall. The levels of S100 β protein at each time point after ROSC in EPO group were significanthy lower than those of the routine chest compression group (83.2 ± 7.5 vs. 114.3 ± 15.3 at 6 hours, 123.9 ± 20.2 vs. 184.9 ± 22.2 at 12 hours, 276.7 ± 28.9 vs. 305.7 ± 29.2 at 24 hours, 256.3 ± 26.6 vs. 283.2 ± 23.6 at 48 hours, all P < 0.05). With the prolongation of ROSC time, the S100 β protein positive cell number in brain (cells/HP) in the routine chest compression group and the EPO group was significantly increased, peaking at 24 hours (compared with CA: 14.3 ± 2.2 vs. 6.7 ± 0.7 in the routine chest compression group, 11.3 ± 1.3 vs. 6.8 ± 0.9 in the EPO group, both P < 0.05), then it began to fall. The S100 β protein positive cell number in brain at each time point after ROSC in the EPO group was significantly lower than that of the routine chest compression group (7.0 ± 0.9 vs. 7.9 ± 1.9 at 6 hours, 8.4 ± 1.1 vs. 10.2 ± 2.2 at 12 hours, 11.3 ± 1.3 vs. 14.3 ± 2.2 at 24 hours, 8.3 ± 0.8 vs. 10.8 ± 2.0 at 48 hours, all P < 0.05). Under the light microscope, a serious brain cortex injury was found after reproduction of the model, and the degree of injury was reduced after EPO intervention. The pathological score at 24 hours after ROSC in EPO group was lower than that of routine chest compression group (3.83 ± 0.73 vs. 4.17 ± 0.75, P < 0.05). The S100 β protein level in serum and brain tissue was increased early in asphyxia CA-CPR rats. EPO intervention can reduce the expression of S100 protein and reduce the degree of brain injury.
Transceiver Design for CMUT-Based Super-Resolution Ultrasound Imaging.
Behnamfar, Parisa; Molavi, Reza; Mirabbasi, Shahriar
2016-04-01
A recently introduced structure for the capacitive micromachined ultrasonic transducers (CMUTs) has focused on the applications of the asymmetric mode of vibration and has shown promising results in construction of super-resolution ultrasound images. This paper presents the first implementation and experimental results of a transceiver circuit to interface such CMUT structures. The multiple input/multiple output receiver in this work supports both fundamental and asymmetric modes of operation and includes transimpedance amplifiers and low-power variable-gain stages. These circuit blocks are designed considering the trade-offs between gain, input impedance, noise, linearity and power consumption. The high-voltage transmitter can generate pulse voltages up to 60 V while occupying a considerably small area. The overall circuit is designed and laid out in a 0.35 μm CMOS process and a four-channel transceiver occupies 0.86 × 0.38 mm(2). The prototype chip is characterized in both electrical and mechanical domains. Measurement results show that each receiver channel has a nominal gain of 110 dBΩ with a 3 dB bandwidth of 9 MHz while consuming 1.02 mW from a 3.3 V supply. The receiver is also highly linear, with 1 dB compression point of minimum 1.05 V which is considerably higher than the previously reported designs. The transmitter consumes 98.1 mW from a 30 V supply while generating 1.38 MHz, 30 V pulses. The CMOS-CMUT system is tested in the transmit mode and shows full functionality in air medium.
Schönbach, Etienne M; Wolfson, Yulia; Strauss, Rupert W; Ibrahim, Mohamed A; Kong, Xiangrong; Muñoz, Beatriz; Birch, David G; Cideciyan, Artur V; Hahn, Gesa-Astrid; Nittala, Muneeswar; Sunness, Janet S; Sadda, SriniVas R; West, Sheila K; Scholl, Hendrik P N
2017-07-01
New outcome measures for treatment trials for Stargardt disease type 1 (STGD1) and other macular diseases are needed. Microperimetry allows mapping of light sensitivity of the macula and provides topographic information on visual function beyond visual acuity. To measure and analyze retinal light sensitivity of the macula in STGD1 using fundus-controlled perimetry (microperimetry). This was a multicenter prospective cohort study. A total of 199 patients and 326 eyes with molecularly confirmed (ABCA4) STGD1 underwent testing with the Nidek MP-1 microperimeter as part of the multicenter, prospective Natural History of the Progression of Atrophy Secondary to Stargardt Disease (ProgStar) study. Sensitivity of 68 retinal loci was tested, and the mean sensitivity (MS) was determined; each point was categorized as "normal," "relative," or "deep" scotoma. Mean sensitivity and the number of points with normal sensitivity, relative, or deep scotomas. Mean (SD) patient age was 34.2 (14.7) years, mean (SD) best-corrected visual acuity of all eyes was 47.8 (16.9) Early Treatment Diabetic Retinopathy Study letter score (approximately 20/100 Snellen equivalent), and mean MS of all eyes of all 68 points was 11.0 (5.0) dB. The median number of normal points per eye was 49 (mean [SD], 41.3 [20.8]; range, 0-68); abnormal sensitivity and deep scotomas were more prevalent in the central macula. Mean sensitivity was lower in the fovea (mean [SD], 2.7 [4.4] dB) than in the inner (mean [SD], 6.8 [5.8] dB) and outer ring (mean [SD], 12.7 [5.3] dB). Overall MS per eye was 0.086 dB lower per year of additional age (95% CI, -0.13 to -0.041; P < .001) and 0.21 dB lower per additional year of duration of STGD1 (95% CI, -0.28 to -0.14; P < .001). Longer duration of STGD1 was associated with worse MS (β = -0.18; P < .001), with a lower number of normal test points (β = -0.71; P < .001), and with a higher number of deep scotoma points (β = -0.70; P < .001). We found 11 eyes with low MS (<6 dB) but very good best-corrected visual acuity of at least 72 Early Treatment Diabetic Retinopathy Study letter score (20/40 Snellen equivalent). We provide an extensive analysis of macular sensitivity parameters in STGD1 and demonstrate their association with demographic characteristics and vision. These data suggest microperimetry testing provides a more comprehensive assessment of retinal function and will be an important outcome measure in future clinical trials.
Pattern of age-associated decline of static and dynamic balance in community-dwelling older women.
Takeshima, Nobuo; Islam, Mohammod M; Rogers, Michael E; Koizumi, Daisuke; Tomiyama, Naoki; Narita, Makoto; Rogers, Nicole L
2014-07-01
Falling is the leading cause of injury-related deaths in older adults, and a loss of balance is often the precursor to a fall. However, little is known about the rate at which balance declines with age. The objective of the present study was to determine whether there is an age-associated decline in static (SB) and/or dynamic (DB) balance in community-dwelling older women. SB and DB were determined in 971 older women. Intraclass correlation coefficients (ICC) were used to determine test-retest reliability. Sway velocity was used to measure SB standing on a platform and foam with eyes open and closed. DB was characterized by limits of stability (LOS) that measured end-point excursion (EXE) and maximum excursion (MXE) of the body's center of pressure. ICC for EXE and MXE for the LOS test were excellent (EPE = 0.96, MXE = 0.96). ICC for SB tests, except for the eyes open firm surface condition (ICC = 0.10), showed a high level of reproducibility (ICC = 0.88 and 0.90). Relationships existed between age and SB (r = 0.31, P < 0.001), and between age and DB (r = -0.46--0.48, P < 0.001). The rate of decline for both DB and SB was approximately 1% per year. Age was significantly associated with all balance measures. DB got significantly lower with advancing age until 80 years, and then plateaued. SB did not decline with age until 80 years, and then decreased significantly thereafter. Although large individual variation was found with balance ability, an age-related decline was found with both dynamic and static balance for Japanese older women. © 2013 Japan Geriatrics Society.
Virtual viewpoint generation for three-dimensional display based on the compressive light field
NASA Astrophysics Data System (ADS)
Meng, Qiao; Sang, Xinzhu; Chen, Duo; Guo, Nan; Yan, Binbin; Yu, Chongxiu; Dou, Wenhua; Xiao, Liquan
2016-10-01
Virtual view-point generation is one of the key technologies the three-dimensional (3D) display, which renders the new scene image perspective with the existing viewpoints. The three-dimensional scene information can be effectively recovered at different viewing angles to allow users to switch between different views. However, in the process of multiple viewpoints matching, when N free viewpoints are received, we need to match N viewpoints each other, namely matching C 2N = N(N-1)/2 times, and even in the process of matching different baselines errors can occur. To address the problem of great complexity of the traditional virtual view point generation process, a novel and rapid virtual view point generation algorithm is presented in this paper, and actual light field information is used rather than the geometric information. Moreover, for better making the data actual meaning, we mainly use nonnegative tensor factorization(NTF). A tensor representation is introduced for virtual multilayer displays. The light field emitted by an N-layer, M-frame display is represented by a sparse set of non-zero elements restricted to a plane within an Nth-order, rank-M tensor. The tensor representation allows for optimal decomposition of a light field into time-multiplexed, light-attenuating layers using NTF. Finally, the compressive light field of multilayer displays information synthesis is used to obtain virtual view-point by multiple multiplication. Experimental results show that the approach not only the original light field is restored with the high image quality, whose PSNR is 25.6dB, but also the deficiency of traditional matching is made up and any viewpoint can obtained from N free viewpoints.
A highly linear power amplifier for WLAN
NASA Astrophysics Data System (ADS)
Jie, Jin; Jia, Shi; Baoli, Ai; Xuguang, Zhang
2016-02-01
A three-stage power amplifier (PA) for WLAN application in 2.4-2.5 GHz is presented. The proposed PA employs an adaptive bias circuit to adjust the operating point of the PA to improve the linearity of the PA. Two methods to short the 2nd harmonic circuit are compared in the area of efficiency and gain of the PA. The PA is taped out in the process of 2 μm InGaP/GaAs HBT and is tested by the evaluation board. The measured results show that 31.5 dB power gain and 29.3 dBm P1dB with an associated 40.4% power added efficiency (PAE) under the single tone stimulus. Up to 26.5 dBm output power can be achieved with an error vector magnitude (EVM) of lower than 3% under the 64QAM/OFDM WLAN stimulus. Project supported by the National Natural Science Foundation of China (No. 61201244) and the Natural Science Fund of SUES (No. E1-0501-14-0168).
Anti-diabetic effect of Alpinia oxyphylla extract on 57BL/KsJ db-/db- mice
Xie, Yiqiang; Xiao, Man; Li, Dan; Liu, Hongqin; Yun, Fenglin; Wei, Yi; Sang, Shenggang; Du, Guankui
2017-01-01
Diabetes mellitus is characterized by high blood glucose levels. Increased levels of reactive oxygen species (ROS) may disrupt insulin signaling and result in insulin resistance. The Alpinia oxyphylla extract (AOE) possesses powerful antioxidant activity and may therefore inhibit the development of insulin resistance. The objective of the present study was to determine the effects of AOE on blood glucose, insulin and lipid levels in a type II diabetic nephropathy animal model (C57BIKsj db-/db-). All experiments were performed on male C57BL/Ks DB/DB and db-/db- mice that were left to acclimatize for 1 week prior to the experimental period. AOE was administered to these mice at different dosages (100, 300 and 500 mg/kg) for 8 weeks. The results demonstrated that AOE did not affect mouse weight, while blood glucose concentrations were found to significantly decrease in a dose-dependent manner (P<0.05). The effect of administering 500 mg/kg AOE (AOE500) to db-/db- mice was tested further. Treatment with AOE500 for 8 weeks led to improved glucose tolerance and reduced plasma insulin concentrations (P<0.05), as well as a significant decrease in triglyceride concentrations (P<0.05) and levels of total cholesterol (P<0.05) in db-/db- mice. Furthermore, treatment with AOE500 decreased the concentration of malondialdehyde, elevated the concentration of glutathione and increased the activities of the antioxidant enzymes superoxide dismutase and peroxidase (P<0.05) in the livers of db-/db- mice. Meanwhile, AOE-treated mice exhibited significantly reduced urine albumin, creatinine and blood urea nitrogen excretion (P<0.05). In parallel, the upregulated expression of phosphatase and tensin homolog (PTEN) in the liver and kidneys of db-/db- mice was impaired following AOE500 treatment. The results of the present study suggest that AOE regulates blood glucose and lipid levels and improves renal function by mediating oxidative stress and PTEN expression at the onset of type II diabetes mellitus. PMID:28413472
Repeatability of normal multifocal VEP: implications for detecting progression.
Fortune, Brad; Demirel, Shaban; Zhang, Xian; Hood, Donald C; Johnson, Chris A
2006-04-01
To assess the repeatability of the multifocal visual evoked potential (mfVEP) and to compare it with the repeatability of standard automated perimetry (SAP) in the same group of 50 normal controls retested after 1 year. Our second aim was to assess the repeatability of false alarm rates determined previously for the mfVEP using various cluster criteria. Fifty individuals with normal vision participated in this study (33 females and 17 males). The age range was 26.7 to 77.9 years and the group average age (+/- SD) was 51.4 (+/- 12.1) years. Pattern-reversal mfVEPs were obtained using a dartboard stimulus pattern in VERIS and two 8-minute runs per eye were averaged. The average number of days between the first and second mfVEP tests was 378 (+/- 58). SAP visual fields were obtained within 17.4 (+/- 20.3) days of the mfVEP using the SITA-standard threshold algorithm. Repeatability of mfVEPs and SAP total deviation values were evaluated by calculating point-wise limits of agreement (LOA). Specificity (1-false alarm rate) was evaluated for a range of cluster criteria, whereby the number and probability level of the points defining a cluster were varied. Point-wise LOA for the mfVEP signal-to-noise ratio (SNR) ranged from 2.0 to 4.3 dB, with an average of 2.9 dB across all 60 locations. For SAP, LOA ranged from 2.4 to 8.9 dB, with an average of 4.0 dB (excluding the points immediately above and below the blind spot). Clusters of abnormal points were not likely to repeat on either mfVEP or SAP. When an mfVEP abnormality was defined as the repeat presence (confirmation) of a 3-point (P < 0.05) cluster anywhere within a single hemifield, only 1 (of 200) monocular hemifield was deemed abnormal. Although the LOA of the mfVEP were similar throughout the field, the limited dynamic range of SNR at superior field locations will limit the ability to follow progression in "depth" at those locations. Repeatability of the mfVEP was slightly better than SAP visual fields in this group of controls with a 1-year retest interval. This suggests that progression in early stages should be more easily detectable by mfVEP. However, in certain field locations (eg, superior periphery), the relatively more narrow dynamic range of the SNR of the mfVEP may limit detection of progression to just 1 event. Confirmation of a 3-point cluster abnormality is highly suggestive of a true defect on the mfVEP.
A Wireless Headstage for Combined Optogenetics and Multichannel Electrophysiological Recording.
Gagnon-Turcotte, Gabriel; LeChasseur, Yoan; Bories, Cyril; Messaddeq, Younes; De Koninck, Yves; Gosselin, Benoit
2017-02-01
This paper presents a wireless headstage with real-time spike detection and data compression for combined optogenetics and multichannel electrophysiological recording. The proposed headstage, which is intended to perform both optical stimulation and electrophysiological recordings simultaneously in freely moving transgenic rodents, is entirely built with commercial off-the-shelf components, and includes 32 recording channels and 32 optical stimulation channels. It can detect, compress and transmit full action potential waveforms over 32 channels in parallel and in real time using an embedded digital signal processor based on a low-power field programmable gate array and a Microblaze microprocessor softcore. Such a processor implements a complete digital spike detector featuring a novel adaptive threshold based on a Sigma-delta control loop, and a wavelet data compression module using a new dynamic coefficient re-quantization technique achieving large compression ratios with higher signal quality. Simultaneous optical stimulation and recording have been performed in-vivo using an optrode featuring 8 microelectrodes and 1 implantable fiber coupled to a 465-nm LED, in the somatosensory cortex and the Hippocampus of a transgenic mouse expressing ChannelRhodospin (Thy1::ChR2-YFP line 4) under anesthetized conditions. Experimental results show that the proposed headstage can trigger neuron activity while collecting, detecting and compressing single cell microvolt amplitude activity from multiple channels in parallel while achieving overall compression ratios above 500. This is the first reported high-channel count wireless optogenetic device providing simultaneous optical stimulation and recording. Measured characteristics show that the proposed headstage can achieve up to 100% of true positive detection rate for signal-to-noise ratio (SNR) down to 15 dB, while achieving up to 97.28% at SNR as low as 5 dB. The implemented prototype features a lifespan of up to 105 minutes, and uses a lightweight (2.8 g) and compact [Formula: see text] rigid-flex printed circuit board.
HippDB: a database of readily targeted helical protein-protein interactions.
Bergey, Christina M; Watkins, Andrew M; Arora, Paramjit S
2013-11-01
HippDB catalogs every protein-protein interaction whose structure is available in the Protein Data Bank and which exhibits one or more helices at the interface. The Web site accepts queries on variables such as helix length and sequence, and it provides computational alanine scanning and change in solvent-accessible surface area values for every interfacial residue. HippDB is intended to serve as a starting point for structure-based small molecule and peptidomimetic drug development. HippDB is freely available on the web at http://www.nyu.edu/projects/arora/hippdb. The Web site is implemented in PHP, MySQL and Apache. Source code freely available for download at http://code.google.com/p/helidb, implemented in Perl and supported on Linux. arora@nyu.edu.
Large signal design - Performance and simulation of a 3 W C-band GaAs power MMIC
NASA Astrophysics Data System (ADS)
White, Paul M.; Hendrickson, Mary A.; Chang, Wayne H.; Curtice, Walter R.
1990-04-01
This paper describes a C-band GaAs power MMIC amplifier that achieved a gain of 17 dB and 1 dB compressed CW power output of 34 dBm across a 4.5-6.25-GHz frequency range, without design iteration. The first-pass design success was achieved due to the application of a harmonic balance simulator to define the optimum output load, using a large-signal FET model determined statistically on a well controlled foundry-ready process line. The measured performance was close to that predicted by a full harmonic balance circuit analysis.
Wu, Yan-ju; Guo, Xin; Li, Chun-jun; Li, Dai-qing; Zhang, Jie; Yang, Yiping; Kong, Yan; Guo, Hang; Liu, De-min; Chen, Li-ming
2015-02-01
Vildagliptin promotes beta cell survival by inhibiting cell apoptosis. It has been suggested that chronic ER (endoplasmic reticulum) stress triggers beta cell apoptosis. The objective of the study is to explore whether the pro-survival effect of vildagliptin is associated with attenuation of endoplasmic reticulum stress in islets of db/db mice. Vildagliptin was orally administered to db/db mice for 6 weeks, followed by evaluation of beta cell apoptosis by caspase3 activity and TUNEL staining method. Endoplasmic reticulum stress markers were determined with quantitative RT-PCR, immunohistochemistry and immunoblot analysis. After 6 weeks of treatment, vildagliptin treatment increased plasma active GLP-1 levels (22.63±1.19 vs. 11.69±0.44, P<0.001), inhibited beta cell apoptosis as demonstrated by lower amounts of TUNEL staining nuclei (0.37±0.03 vs. 0.55±0.03, P<0.01) as well as decreased caspase3 activity (1.48±0.11 vs. 2.67±0.13, P<0.01) in islets of diabetic mice compared with untreated diabetic group. Further, vildagliptin treatment down-regulated several genes related to endoplasmic reticulum stress including TRIB3 (tribbles homolog 3) (15.9±0.4 vs. 33.3±1.7, ×10⁻³, P<0.001), ATF-4(activating transcription factor 4) (0.83±0.06 vs. 1.42±0.02, P<0.001) and CHOP(C/EBP homologous protein) (0.07±0.01 vs. 0.16±0.01, P<0.001). Vildagliptin promoted beta cell survival in db/db mice in association with down-regulating markers of endoplasmic reticulum stress including TRIB3, ATF-4 as well as CHOP. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Campolina, Bruno L.
The prediction of aircraft interior noise involves the vibroacoustic modelling of the fuselage with noise control treatments. This structure is composed of a stiffened metallic or composite panel, lined with a thermal and acoustic insulation layer (glass wool), and structurally connected via vibration isolators to a commercial lining panel (trim). The goal of this work aims at tailoring the noise control treatments taking design constraints such as weight and space optimization into account. For this purpose, a representative aircraft double-wall is modelled using the Statistical Energy Analysis (SEA) method. Laboratory excitations such as diffuse acoustic field and point force are addressed and trends are derived for applications under in-flight conditions, considering turbulent boundary layer excitation. The effect of the porous layer compression is firstly addressed. In aeronautical applications, compression can result from the installation of equipment and cables. It is studied analytically and experimentally, using a single panel and a fibrous uniformly compressed over 100% of its surface. When compression increases, a degradation of the transmission loss up to 5 dB for a 50% compression of the porous thickness is observed mainly in the mid-frequency range (around 800 Hz). However, for realistic cases, the effect should be reduced since the compression rate is lower and compression occurs locally. Then the transmission through structural connections between panels is addressed using a four-pole approach that links the force-velocity pair at each side of the connection. The modelling integrates experimental dynamic stiffness of isolators, derived using an adapted test rig. The structural transmission is then experimentally validated and included in the double-wall SEA model as an equivalent coupling loss factor (CLF) between panels. The tested structures being flat, only axial transmission is addressed. Finally, the dominant sound transmission paths are identified in the 100 Hz to 10 kHz frequency range for double-walls under diffuse acoustic field and under point-force excitations. Non-resonant transmission is higher at low frequencies (frequencies lower than 1 kHz) while the structure-borne and the airborne paths dominate at mid- and high-frequencies, around 1 kHz and higher, respectively. An experimental validation on double-walls shows that the model is able to predict changes in the overall transmission caused by different structural couplings (rigid coupling, coupling via isolators and structurally uncoupled). Noise reduction means adapted to each transmission path, such as absorption, dissipation and structural decoupling, may be then derived. Keywords: Statistical energy analysis, Vibration isolator, Double-wall, Transfer path analysis, Transmission Loss.
NASA Astrophysics Data System (ADS)
Wang, Jun; Min, Kyeong-Yuk; Chong, Jong-Wha
2010-11-01
Overdrive is commonly used to reduce the liquid-crystal response time and motion blur in liquid-crystal displays (LCDs). However, overdrive requires a large frame memory in order to store the previous frame for reference. In this paper, a high-compression-ratio codec is presented to compress the image data stored in the on-chip frame memory so that only 1 Mbit of on-chip memory is required in the LCD overdrives of mobile devices. The proposed algorithm further compresses the color bitmaps and representative values (RVs) resulting from the block truncation coding (BTC). The color bitmaps are represented by a luminance bitmap, which is further reduced and reconstructed using median filter interpolation in the decoder, while the RVs are compressed using adaptive quantization coding (AQC). Interpolation and AQC can provide three-level compression, which leads to 16 combinations. Using a rate-distortion analysis, we select the three optimal schemes to compress the image data for video graphics array (VGA), wide-VGA LCD, and standard-definitionTV applications. Our simulation results demonstrate that the proposed schemes outperform interpolation BTC both in PSNR (by 1.479 to 2.205 dB) and in subjective visual quality.
Sundaram, S; Cendoroglo, M; Cooker, L A; Jaber, B L; Faict, D; Holmes, C J; Pereira, B J
1997-11-01
Low pH, high osmolality, increasing glucose concentration, and glucose degradation products (GDP) formed during heat sterilization of conventional peritoneal dialysis (PD) fluids have been shown to have a detrimental effect on cells involved in peritoneal host defense. The two-chambered PD fluid bag in which glucose at pH approximately 3 is separated from a bicarbonate (25 mmol/L)-lactate (15 mmol/L) buffer during heat sterilization permits PD fluids with lower GDP to be delivered to the patient at neutral pH. To establish the possible benefit of two-chambered bag PD fluids on peripheral blood mononuclear cell (PBMC) and polymorphonuclear (PMN) cell function, we compared conventional 1.5% Dianeal (1.5%D) with 1.5% two-chambered bag bicarbonate-lactate (1.5%D-B), and conventional 4.25% Dianeal (4.25%D) with 4.25% two-chambered bag bicarbonate-lactate (4.25%D-B). Furthermore, to study the effect of the sterilization process on PBMC and PMN function, we compared filter-sterilized 4.25%D (4.25%D-F) with 4.25%D and 4.25%D-B. PBMC were harvested by Ficoll-Hypaque separation, and 2.5 x 10(6) cells in RPMI were incubated with an equal volume of the test fluids for 4 hours, pelleted, and resuspended in RPMI containing 10 ng endotoxin for a further 20 hours. Tumor necrosis factor alpha (TNF-alpha) production by endotoxin-stimulated PBMC was not significantly different (P = 0.10) between 1.5%D-B and 1.5%D, but was significantly higher (P = 0.01) with 4.25%D-B compared with 4.25%D. PBMC exposed to filter-sterilized fluid (4.25%D-F) showed significantly higher endotoxin-stimulated TNF-alpha production compared with 4.25%D (P = 0.02), but was not significantly different from 4.25%D-B (P = 0.40). PMN were harvested by Ficoll-Hypaque separation and 10 x 10(6) cells incubated with test fluids for 30 minutes. After incubation, phagocytosis (phagocytosis index) was determined by the uptake of 14C-labeled Staphylococcus aureus, oxidative burst by reduction of ferricytochrome C to ferrocytochrome C on stimulation with PMA, and enzyme release by measurement of endotoxin-stimulated bactericidal/permeability increasing protein (BPI). Bicarbonate-lactate two-chambered fluids of similar osmolality and glucose concentration conferred a significant improvement in phagocytosis (P = 0.02 for 1.5%D-B and P < 0.001 for 4.25%D-B). Oxidative burst and BPI release were significantly higher in 4.25%D-B compared with 4.25%D (P < 0.001). Filter-sterilized 4.25%D-F conferred a significant improvement in phagocytosis and oxidative burst compared with 4.25%D (P < 0.001) or 4.25%D-B (P < 0.001). Furthermore, conventional 4.25%D was associated with significantly lower BPI release compared with 4.25%D-F (P = 0.01). GDP's acetaldehyde and 5-HMF were analyzed in 4.25%D-B, 4.25%D, and 4.25%D-F. Acetaldehyde was below the lower limit (0.79 ppm) of the standard curve in 4.25%D-B and 4.25%D-F fluids but was detected (3.76 to 5.12 ppm) in all of the 4.25%D fluids. Relative levels of 5-HMF in the 4.25%D-B (0.032 to 0.041 Abs @ 284 nm) and 4.25%D (0.031 to 0.036 Abs @ 284 nm) were similar. The lowest levels (0.001 Abs @ 284 nm) were observed in the filter-sterilized 4.25%D-F. The beneficial effects of two-chambered bicarbonate lactate-buffered PD fluids on PBMC and PMN function are probably related to reduction of GDP from heat sterilization of glucose in a separate chamber at a lower pH. This improvement in biocompatibility could have a beneficial affect on peritoneal defenses.
NASA Technical Reports Server (NTRS)
Arvin, G. H.; Israeli, L.; Stolpestad, J. H.; Stacher, G. W.
1981-01-01
The application of the superplastic forming/diffusion bonding (SPF/DB) process to supersonic cruise research is investigated. The capability of an SPF/DB titanium structure to meet the structural requirements of the inner wing area of the NASA arrow-wing advanced supersonic transport design is evaluated. Selection of structural concepts and their optimization for minimum weight, SPF/DB process optimization, fabrication of representative specimens, and specimen testing and evaluation are described. The structural area used includes both upper and lower wing panels, where the upper wing panel is used for static compression strength evaluation and the lower panel, in tension, is used for fracture mechanics evaluations. The individual test specimens, cut from six large panels, consist of 39 static specimens, 10 fracture mechanics specimens, and one each full size panel for compression stability and fracture mechanics testing. Tests are performed at temperatures of -54 C (-65 F), room temperature, and 260 C (500 F).
Solid state Ku-band spacecraft transmitters
NASA Technical Reports Server (NTRS)
Wisseman, W. R.; Tserng, H. Q.; Coleman, D. J.; Doerbeck, F. H.
1977-01-01
A transmitter is considered that consists of GaAs IMPATT and Read diodes operating in a microstrip circuit environment to provide amplification with a minimum of 63 db small signal gain and a minimum compressed gain at 5 W output of 57 db. Reported are Schottky-Read diode design and fabrication, microstrip and circulator optimization, preamplifier development, power amplifier development, dc-to-dc converter design, and integration of the breadboard transmitter modules. A four-stage power amplifier in cascade with a three-stage preamplifier had an overall gain of 56.5 db at 13.5 GHz with a power output of 4.5 W. A single-stage Read amplifier delivered 5.9 W with 4 db gain at 22% efficiency.
Valdetara, Federica; Fracassetti, Daniela; Campanello, Alessia; Costa, Carlo; Foschino, Roberto; Compagno, Concetta; Vigentini, Ileana
2017-01-01
Dekkera/Brettanomyces bruxellensis , the main spoilage yeast in barrel-aged wine, metabolize hydroxycinnamic acids into off-flavors, namely ethylphenols. Recently, both the enzymes involved in this transformation, the cinnamate decarboxylase ( DbCD ) and the vinylphenol reductase ( DbVPR ), have been identified. To counteract microbial proliferation in wine, sulfur dioxide (SO 2 ) is used commonly to stabilize the final product, but limiting its use is advised to preserve human health and boost sustainability in winemaking. In the present study, the influence of SO 2 was investigated in relation with pH and ethanol factors on the expression of DbCD and DbVPR genes and volatile phenol production in D. bruxellensis CBS2499 strain under different model wines throughout a response surface methodology (RSM). In order to ensure an exact quantification of DbCD and DbVPR expression, an appropriate housekeeping gene was sought among DbPDC , DbALD , DbEF , DbACT , and DbTUB genes by GeNorm and Normfinder algorithms. The latter gene showed the highest expression stability and it was chosen as the reference housekeeping gene in qPCR assays. Even though SO 2 could not be commented as main factor because of its statistical irrelevance on the response of DbCD gene, linear interactions with pH and ethanol concurred to define a significant effect ( p < 0.05) on its expression. The DbCD gene was generally downregulated respect to a permissive growth condition (0 mg/L mol. SO 2 , pH 4.5 and 5% v/v ethanol); the combination of the factor levels that maximizes its expression (0.83-fold change) was calculated at 0.25 mg/L mol. SO 2 , pH 4.5 and 12.5% (v/v) ethanol. On the contrary, DbVPR expression was not influenced by main factors or by their interactions; however, its expression is maximized (1.80-fold change) at the same conditions calculated for DbCD gene. While no linear interaction between factors influenced the off-flavor synthesis, ethanol and pH produced a significant effect as individual factors. The obtained results can be useful to improve the SO 2 management at the grape harvesting and during winemaking in order to minimize the D./B. bruxellensis spoilage.
Self-Debriefing vs Instructor Debriefing in a Pre-Internship Simulation Curriculum: Night on Call.
Oikawa, Sayaka; Berg, Benjamin; Turban, Joseph; Vincent, Dale; Mandai, Yasuhiro; Birkmire-Peters, Deborah
2016-05-01
This study sought to determine if learner self-performance assessment (SPA) and team-performance assessment (TPA) were different when simulation based education (SBE) was supported by self-debriefing (S-DB), compared to traditional facilitator-led debriefing (F-DB). "One-Night-On-Call," an internship preparation curriculum, was selected to provide SBE. Participants worked as team members in 4 sequential bedside acute care problem-solving scenarios. Fifty-seven learners were randomized to 9 F-DB and 10 S-DB Teams. Participants completed SPA and TPA assessment checklist questionnaires immediately following the first and fourth (final) scenarios. Learner SPA and TPA scores improved overall from the first to the fourth scenarios (P <.05). F-DB versus S-DB cohorts did not differ in overall SPA scores. The F-DB average TPA score was 12.8 (SD±2.1) compared to a S-DB score of 14.1 (SD±2.1) (P =.001). F-DB participants' increase in TPA was due to increases in the Patient Assessment and Treatment sub-domains that exceeded corresponding improvements in the S-DB cohort. Self- debriefing strategies are equivalent to facilitator-led debriefing in some situations. Self-debriefing offers opportunities to enable simulation-based education by decreasing the number of required faculty debriefers, and may be uniquely well matched to simulation-based teamwork training.
Bruder-Nascimento, Thiago; Callera, Glaucia; Montezano, Augusto Cesar; Antunes, Tayze T.; He, Ying; Cat, Aurelie Nguyen Dinh; Ferreira, Nathanne S.; Barreto, Pedro A.; Olivon, Vânia C.; Tostes, Rita C.; Touyz, Rhian M.
2016-01-01
Potential benefits of statins in the treatment of chronic kidney disease beyond lipid-lowering effects have been described. However, molecular mechanisms involved in renoprotective actions of statins have not been fully elucidated. We questioned whether statins influence development of diabetic nephropathy through reactive oxygen species, RhoA and Akt/GSK3 pathway, known to be important in renal pathology. Diabetic mice (db/db) and their control counterparts (db/+) were treated with atorvastatin (10 mg/Kg/day, p.o., for 2 weeks). Diabetes-associated renal injury was characterized by albuminuria (albumin:creatinine ratio, db/+: 3.2 ± 0.6 vs. db/db: 12.5 ± 3.1*; *P<0.05), increased glomerular/mesangial surface area, and kidney hypertrophy. Renal injury was attenuated in atorvastatin-treated db/db mice. Increased ROS generation in the renal cortex of db/db mice was also inhibited by atorvastatin. ERK1/2 phosphorylation was increased in the renal cortex of db/db mice. Increased renal expression of Nox4 and proliferating cell nuclear antigen, observed in db/db mice, were abrogated by statin treatment. Atorvastatin also upregulated Akt/GSK3β phosphorylation in the renal cortex of db/db mice. Our findings suggest that atorvastatin attenuates diabetes-associated renal injury by reducing ROS generation, RhoA activity and normalizing Akt/GSK3β signaling pathways. The present study provides some new insights into molecular mechanisms whereby statins may protect against renal injury in diabetes. PMID:27649495
Short latency vestibular evoked potentials in the Japanese quail (Coturnix coturnix japonica)
NASA Technical Reports Server (NTRS)
Jones, S. M.; Jones, T. A.; Shukla, R.
1997-01-01
Short-latency vestibular-evoked potentials to pulsed linear acceleration were characterized in the quail. Responses occurred within 8 ms following the onset of stimuli and were composed of a series of positive and negative peaks. The latencies and amplitudes of the first four peaks were quantitatively characterized. Mean latencies at 1.0 g ms-1 ranged from 1265 +/- 208 microseconds (P1, N = 18) to 4802 +/- 441 microseconds (N4, N = 13). Amplitudes ranged from 3.72 +/- 1.51 microV (P1/N1, N = 18) to 1.49 +/- 0.77 microV (P3/N3, N = 16). Latency-intensity (LI) slopes ranged from -38.7 +/- 7.3 microseconds dB-1 (P1, N = 18) to -71.6 +/- 21.9 microseconds dB-1 (N3, N = 15) and amplitude-intensity (AI) slopes ranged from 0.20 +/- 0.08 microV dB-1 (P1/N1, N = 18) to 0.07 +/- 0.04 microV dB-1 (P3/N3, N = 11). The mean response threshold across all animals was -21.83 +/- 3.34 dB re: 1.0 g ms-1 (N = 18). Responses remained after cochlear extirpation showing that they could not depend critically on cochlear activity. Responses were eliminated by destruction of the vestibular end organs, thus showing that responses depended critically and specifically on the vestibular system. The results demonstrate that the responses are vestibular and the findings provide a scientific basis for using vestibular responses to evaluate vestibular function through ontogeny and senescence in the quail.
Comparative Analysis of Red-Edge Hyperspectral Indices
NASA Astrophysics Data System (ADS)
Gupta, R.; Vijayan, D.; Prasad, T.
The spectrally continuous observations of 3 nm bandwidth in 680 to 800 nm range over the growth cycle of wheat were subjected to first order differentiation to identify the point of inflection in red to near-IR transition zone. During 40 to 84 days after sowing (DAS), the point of inflection was observed in 723 to 735 nm region with peak response at 729 nm for 64 DAS . For differentiated curve pertaining to 25 DAS (initial vegetative) and 90 DAS (initial senescence) phenological stages, the point of inflection was in 690-693 and 744-747 nm spectral region, respectively. The ratios corresponding to 1dB (RI1dB = R 735 /R720), 2dB (RI 2dB = R738/R 720), 3dB (RI3dB = R741 /R 717) down signal levels and half signal level (RIhalf = R747/R 708 ) were computed. For nomenclature point of view, R41 refers to reflectance for 3 nm7 bandwidth centered at 741 nm. Correlations for these developed RIs were studied with reference to indices given by Vogelmann i.e., VOG a = R 740 /R720 , VOG b = [(R 734-R747)/(R715+R720)] and red edge spectral parameter (RESP) = R750 /R 710. VOG a and RESP conceptually resemble with developed RI 2dB and RIhalf , respectively. All RIs were found correlated with VOGa , VOG b and RESP with r2 in the range of 0.96 to 0.99; r2 was 0.998 for RI2dB and VOG a pair and 0.996 for RI half and RESP pair; the slope factor of regression relationship improved by about 50% from RI dB to2 RI3dB and by about 125% from RI3dB to RIhalf with r2 in 0.97-0.99 range. Thus, theoretical basis for VOG a and RESP in terms of dB based indices has been provided. The wavelengths used in VOGb are noticed in dB based indices ; to provide stability to small magnitude R720, the sum of R720 and R715 has been used in VOGb. Based on regression analysis of these indices with LAI in its growth and decline phases separately, the slope value for VOG b, RI 2dB, VOG a, RIhalf, RESP and area under 680 to 760 nm for first order derivative curve (area) were in 0.08-0.11, 0.24 - 0.34, 0.27-0.38, 0.86-1.18, 0.89-1.27 and 7.6-13.87 range, respectively. Here, the first value in the range refers to slope value for the growth phase of LAI while the second value in the range refers to that for the decline phase of LAI. To judge the sensitivity for the rate of change in red - edge, the change in area for ratio indices and normalized indices in 680 to 760 nm (red-near IR transition region) with 673 nm were analysed. The rate of change for area under the red edge as a function of DAS was more for ratio indices as compared to that for normalized indices.
Multi-rate, real time image compression for images dominated by point sources
NASA Technical Reports Server (NTRS)
Huber, A. Kris; Budge, Scott E.; Harris, Richard W.
1993-01-01
An image compression system recently developed for compression of digital images dominated by point sources is presented. Encoding consists of minimum-mean removal, vector quantization, adaptive threshold truncation, and modified Huffman encoding. Simulations are presented showing that the peaks corresponding to point sources can be transmitted losslessly for low signal-to-noise ratios (SNR) and high point source densities while maintaining a reduced output bit rate. Encoding and decoding hardware has been built and tested which processes 552,960 12-bit pixels per second at compression rates of 10:1 and 4:1. Simulation results are presented for the 10:1 case only.
Validation of the BOD POD with hydrostatic weighing: influence of body clothing.
Fields, D A; Hunter, G R; Goran, M I
2000-02-01
Whole body air-displacement plethysmography (BOD POD), a new body composition technique, was validated against hydrodensitometry (UWW) in 67 women wearing a one-piece swimsuit (OP) who represent a wide range of body fatness and age. Additionally, the effect of trapped isothermic air in clothing while in the BOD POD was examined by comparing different clothing schemes (a one-piece swimsuit (OP), two-piece swimsuit (TP), a hospital gown (HG), and a hospital gown previously included in a volume calibration (GC)) in a subset of 25 women. Cross-sectional data analysis. 67 healthy Caucasian females. Body density g/cm3 (Db) by BOD POD and UWW. In 67 females UWW Db (1.030+/-0.020 g/cm3) was higher (P<0.01) than BOD POD Db (1. 028+/-0.020 g/cm3). This is a difference of 1.0% fat. The R2 was 0. 94, SEE was 0.005 g/cm3 and the regression between Db by UWW and BOD POB did not significantly deviate from the line of identity. In the subset group of 25 subjects, OP Db (1.040+/-0.014 g/cm3) and TP Db (1.040+/-0.014 g/cm3) were significantly lower (P<0.01) than UWW Db (1.044+/-0.014 g/cm3) or a difference of 1.9% fat. The R2 was 0.86 and the SEE was 0.005 g/cm3 and the regression between Db by UWW and both OP and TP did not significantly deviate from the line of identity. HG Db (1.056+/-0.016 g/cm3) and GC Db (1.037+/-0.016 g/cm3) were significantly different (P<0.01) from UWW Db (1.044+/-0. 014 g/cm3). This difference in density translates to a difference of 5.5% and 3.2% fat respectively. The regression between Db by UWW and both HG and GC significantly deviated from the line of identity. This study supports the use of the BOD POD as a substitute for UWW. However, caution should be made in using the BOD POD if subjects are clothed in anything other than a tight fitting swimsuit.
Deloose, Eveline; Janssen, Pieter; Corsetti, Maura; Biesiekierski, Jessica; Masuy, Imke; Rotondo, Alessandra; Van Oudenhove, Lukas; Depoortere, Inge; Tack, Jan
2017-03-01
Background: Denatonium benzoate (DB) has been shown to influence ongoing ingestive behavior and gut peptide secretion. Objective: We studied how the intragastric administration of DB affects interdigestive motility, motilin and ghrelin plasma concentrations, hunger and satiety ratings, and food intake in healthy volunteers. Design: Lingual bitter taste sensitivity was tested with the use of 6 concentrations of DB in 65 subjects. A placebo or 1 μmol DB/kg was given intragastrically to assess its effect on fasting gastrointestinal motility and hunger ratings, motilin and ghrelin plasma concentrations, satiety, and caloric intake. Results: Women ( n = 39) were more sensitive toward a lingual bitter stimulus ( P = 0.005) than men ( n = 26). In women ( n = 10), intragastric DB switched the origin of phase III contractions from the stomach to the duodenum ( P = 0.001) and decreased hunger ratings ( P = 0.04). These effects were not observed in men ( n = 10). In women ( n = 12), motilin ( P = 0.04) plasma concentrations decreased after intragastric DB administration, whereas total and octanoylated ghrelin were not affected. The intragastric administration of DB decreased hunger ( P = 0.008) and increased satiety ratings ( P = 0.01) after a meal (500 kcal) in 13 women without affecting gastric emptying in 6 women. Caloric intake tended to decrease after DB administration compared with the placebo (mean ± SEM: 720 ± 58 compared with 796 ± 45 kcal; P = 0.08) in 20 women. Conclusions: Intragastric DB administration decreases both antral motility and hunger ratings during the fasting state, possibly because of a decrease in motilin release. Moreover, DB decreases hunger and increases satiety ratings after a meal and shows potential for decreasing caloric intake. This trial was registered at clinicaltrials.gov as NCT02759926. © 2017 American Society for Nutrition.
High Performance Power Amplifiers Utilizing Novel Balun Design Techniques
NASA Astrophysics Data System (ADS)
Stameroff, Alexander Nicholas
In this PhD. research, a new power amplifier architecture is introduced. This work develops the push-pull architecture into a multifunctional matching network and combiner to create a high power, high efficiency, linear power amplifier (PA) that operates over a wide bandwidth. The traditional push-pull architecture uses an input balun to split a single ended signal into a differential signal, amplify it, and recombine it. This new technique realizes this architecture as a planar, hybrid, PA in X band. The first contribution of this work is the development of planar Marchand baluns that operate over a wide bandwidth. An analysis technique is developed and broadside coupled, Marchand baluns in an inhomogeneous medium are employed. These baluns operate over a bandwidth from 5 to 26 GHz with amplitude and phase imbalances less than 0.5 dB and 5 °, respectively. The even and odd mode behavior of the Marchand balun is utilized to provide harmonic matching for the PA. The balun inherently presents an open circuit to common mode signals at its center frequency. This is utilized to match the second harmonic to an open circuit condition. A band-stop filter is used as a harmonic trap to match the third harmonic to a short circuit. This achieves inverse class F matching for high efficiency operation. This network simultaneously acts as a combiner and matching network for high power and efficiency. A prototype PA was fabricated to prove this concept and achieves a saturated output power, Psat, greater than 33 dBm and a power added efficiency, PAE, greater than 62% over the bandwidth from 9.7 to 10.3 GHz. This technique was refined to operate over a wide bandwidth. The harmonic trap was removed and the out-of-band behavior of the balun was used to provide the short circuit matching at the third harmonic. A prototype PA was fabricated that achieved a 1 dB compressed power, P1dB, and PAE greater than 40 dBm and 55% respectively over the band from 8 to 12 GHz. Finally, the technique was extended to combine power from four transistors by the development of a 4-to-1 balun. A prototype PA was fabricated to prove this concept and achieves a P1dB and PAE greater than 43 dBm and 55% over the band from 8 to 12 GHz.
Barbier, Paolo; Alimento, Marina; Berna, Giovanni; Celeste, Fabrizio; Gentile, Francesco; Mantero, Antonio; Montericcio, Vincenzo; Muratori, Manuela
2007-05-01
Large files produced by standard compression algorithms slow down spread of digital and tele-echocardiography. We validated echocardiographic video high-grade compression with the new Motion Pictures Expert Groups (MPEG)-4 algorithms with a multicenter study. Seven expert cardiologists blindly scored (5-point scale) 165 uncompressed and compressed 2-dimensional and color Doppler video clips, based on combined diagnostic content and image quality (uncompressed files as references). One digital video and 3 MPEG-4 algorithms (WM9, MV2, and DivX) were used, the latter at 3 compression levels (0%, 35%, and 60%). Compressed file sizes decreased from 12 to 83 MB to 0.03 to 2.3 MB (1:1051-1:26 reduction ratios). Mean SD of differences was 0.81 for intraobserver variability (uncompressed and digital video files). Compared with uncompressed files, only the DivX mean score at 35% (P = .04) and 60% (P = .001) compression was significantly reduced. At subcategory analysis, these differences were still significant for gray-scale and fundamental imaging but not for color or second harmonic tissue imaging. Original image quality, session sequence, compression grade, and bitrate were all independent determinants of mean score. Our study supports use of MPEG-4 algorithms to greatly reduce echocardiographic file sizes, thus facilitating archiving and transmission. Quality evaluation studies should account for the many independent variables that affect image quality grading.
Self-Debriefing vs Instructor Debriefing in a Pre-Internship Simulation Curriculum: Night on Call
Oikawa, Sayaka; Turban, Joseph; Vincent, Dale; Mandai, Yasuhiro; Birkmire-Peters, Deborah
2016-01-01
This study sought to determine if learner self-performance assessment (SPA) and team-performance assessment (TPA) were different when simulation based education (SBE) was supported by self-debriefing (S-DB), compared to traditional facilitator-led debriefing (F-DB). “One-Night-On-Call,” an internship preparation curriculum, was selected to provide SBE. Participants worked as team members in 4 sequential bedside acute care problem-solving scenarios. Fifty-seven learners were randomized to 9 F-DB and 10 S-DB Teams. Participants completed SPA and TPA assessment checklist questionnaires immediately following the first and fourth (final) scenarios. Learner SPA and TPA scores improved overall from the first to the fourth scenarios (P <.05). F-DB versus S-DB cohorts did not differ in overall SPA scores. The F-DB average TPA score was 12.8 (SD±2.1) compared to a S-DB score of 14.1 (SD±2.1) (P =.001). F-DB participants' increase in TPA was due to increases in the Patient Assessment and Treatment sub-domains that exceeded corresponding improvements in the S-DB cohort. Self- debriefing strategies are equivalent to facilitator-led debriefing in some situations. Self-debriefing offers opportunities to enable simulation-based education by decreasing the number of required faculty debriefers, and may be uniquely well matched to simulation-based teamwork training. PMID:27239391
NASA Astrophysics Data System (ADS)
Nguyen, Thu-Mai; Song, Shaozhen; Arnal, Bastien; Wong, Emily Y.; Huang, Zhihong; Wang, Ruikang K.; O'Donnell, Matthew
2014-01-01
Assessing the biomechanical properties of soft tissue provides clinically valuable information to supplement conventional structural imaging. In the previous studies, we introduced a dynamic elastography technique based on phase-sensitive optical coherence tomography (PhS-OCT) to characterize submillimetric structures such as skin layers or ocular tissues. Here, we propose to implement a pulse compression technique for shear wave elastography. We performed shear wave pulse compression in tissue-mimicking phantoms. Using a mechanical actuator to generate broadband frequency-modulated vibrations (1 to 5 kHz), induced displacements were detected at an equivalent frame rate of 47 kHz using a PhS-OCT. The recorded signal was digitally compressed to a broadband pulse. Stiffness maps were then reconstructed from spatially localized estimates of the local shear wave speed. We demonstrate that a simple pulse compression scheme can increase shear wave detection signal-to-noise ratio (>12 dB gain) and reduce artifacts in reconstructing stiffness maps of heterogeneous media.
Valdetara, Federica; Fracassetti, Daniela; Campanello, Alessia; Costa, Carlo; Foschino, Roberto; Compagno, Concetta; Vigentini, Ileana
2017-01-01
Dekkera/Brettanomyces bruxellensis, the main spoilage yeast in barrel-aged wine, metabolize hydroxycinnamic acids into off-flavors, namely ethylphenols. Recently, both the enzymes involved in this transformation, the cinnamate decarboxylase (DbCD) and the vinylphenol reductase (DbVPR), have been identified. To counteract microbial proliferation in wine, sulfur dioxide (SO2) is used commonly to stabilize the final product, but limiting its use is advised to preserve human health and boost sustainability in winemaking. In the present study, the influence of SO2 was investigated in relation with pH and ethanol factors on the expression of DbCD and DbVPR genes and volatile phenol production in D. bruxellensis CBS2499 strain under different model wines throughout a response surface methodology (RSM). In order to ensure an exact quantification of DbCD and DbVPR expression, an appropriate housekeeping gene was sought among DbPDC, DbALD, DbEF, DbACT, and DbTUB genes by GeNorm and Normfinder algorithms. The latter gene showed the highest expression stability and it was chosen as the reference housekeeping gene in qPCR assays. Even though SO2 could not be commented as main factor because of its statistical irrelevance on the response of DbCD gene, linear interactions with pH and ethanol concurred to define a significant effect (p < 0.05) on its expression. The DbCD gene was generally downregulated respect to a permissive growth condition (0 mg/L mol. SO2, pH 4.5 and 5% v/v ethanol); the combination of the factor levels that maximizes its expression (0.83-fold change) was calculated at 0.25 mg/L mol. SO2, pH 4.5 and 12.5% (v/v) ethanol. On the contrary, DbVPR expression was not influenced by main factors or by their interactions; however, its expression is maximized (1.80-fold change) at the same conditions calculated for DbCD gene. While no linear interaction between factors influenced the off-flavor synthesis, ethanol and pH produced a significant effect as individual factors. The obtained results can be useful to improve the SO2 management at the grape harvesting and during winemaking in order to minimize the D./B. bruxellensis spoilage. PMID:28955312
Wang, Jie-Mei; Tao, Jun; Chen, Dan-Dan; Cai, Jing-Jing; Irani, Kaikobad; Wang, Qinde; Yuan, Hong; Chen, Alex F
2014-01-01
Vascular precursor cells with angiogenic potentials are important for tissue repair, which is impaired in diabetes mellitus. MicroRNAs are recently discovered key regulators of gene expression, but their role in vascular precursor cell-mediated angiogenesis in diabetes mellitus is unknown. We tested the hypothesis that the microRNA miR-27b rescues impaired bone marrow-derived angiogenic cell (BMAC) function in vitro and in vivo in type 2 diabetic mice. BMACs from adult male type 2 diabetic db/db and from normal littermate db/+ mice were used. miR-27b expression was decreased in db/db BMACs. miR-27b mimic improved db/db BMAC function, including proliferation, adhesion, tube formation, and delayed apoptosis, but it did not affect migration. Elevated thrombospondin-1 (TSP-1) protein in db/db BMACs was suppressed on miR-27b mimic transfection. Inhibition of miR-27b in db/+ BMACs reduced angiogenesis, which was reversed by TSP-1 small interfering RNA (siRNA). miR-27b suppressed the pro-oxidant protein p66(shc) and mitochondrial oxidative stress, contributing to its protection of BMAC function. miR-27b also suppressed semaphorin 6A to improve BMAC function in diabetes mellitus. Luciferase binding assay suggested that miR-27b directly targeted TSP-1, TSP-2, p66(shc), and semaphorin 6A. miR-27b improved topical cell therapy of diabetic BMACs on diabetic skin wound closure, with a concomitant augmentation of wound perfusion and capillary formation. Normal BMAC therapy with miR-27b inhibition demonstrated reduced efficacy in wound closure, perfusion, and capillary formation. Local miR-27b delivery partly improved wound healing in diabetic mice. miR-27b rescues impaired BMAC angiogenesis via TSP-1 suppression, semaphorin 6A expression, and p66shc-dependent mitochondrial oxidative stress and improves BMAC therapy in wound healing in type 2 diabetic mice.
[Environmental noise levels in 2 intensive care units in a tertiary care centre].
Ornelas-Aguirre, José Manuel; Zárate-Coronado, Olivia; Gaxiola-González, Fabiola; Neyoy-Sombra, Venigna
2017-04-03
The World Health Organisation (WHO) has established a maximum noise level of 40 decibels (dB) for an intensive care unit. The aim of this study was to compare the noise levels in 2 different intensive care units at a tertiary care centre. Using a cross-sectional design study, an analysis was made of the maximum noise level was within the intensive coronary care unit and intensive care unit using a digital meter. A measurement was made in 4 different points of each room, with 5minute intervals, for a period of 60minutes 7:30, 14:30, and 20:30. The means of the observations were compared with descriptive statistics and Mann-Whitney U. An analysis with Kruskal-Wallis test was performed to the mean noise level. The noise observed in the intensive care unit had a mean of 64.77±3.33dB (P=.08), which was similar to that in the intensive coronary care unit, with a mean of 60.20±1.58dB (P=.129). Around 25% or more of the measurements exceeded the level recommended by the WHO by up to 20 points. Noise levels measured in intensive care wards exceed the maximum recommended level for a hospital. It is necessary to design and implement actions for greater participation of health personnel in the reduction of environmental noise. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.
Spatially adaptive bases in wavelet-based coding of semi-regular meshes
NASA Astrophysics Data System (ADS)
Denis, Leon; Florea, Ruxandra; Munteanu, Adrian; Schelkens, Peter
2010-05-01
In this paper we present a wavelet-based coding approach for semi-regular meshes, which spatially adapts the employed wavelet basis in the wavelet transformation of the mesh. The spatially-adaptive nature of the transform requires additional information to be stored in the bit-stream in order to allow the reconstruction of the transformed mesh at the decoder side. In order to limit this overhead, the mesh is first segmented into regions of approximately equal size. For each spatial region, a predictor is selected in a rate-distortion optimal manner by using a Lagrangian rate-distortion optimization technique. When compared against the classical wavelet transform employing the butterfly subdivision filter, experiments reveal that the proposed spatially-adaptive wavelet transform significantly decreases the energy of the wavelet coefficients for all subbands. Preliminary results show also that employing the proposed transform for the lowest-resolution subband systematically yields improved compression performance at low-to-medium bit-rates. For the Venus and Rabbit test models the compression improvements add up to 1.47 dB and 0.95 dB, respectively.
Single-Shot Readout of a Superconducting Qubit using a Josephson Parametric Oscillator
2016-01-11
Gustavsson2, Vitaly Shumeiko1, W.D. Oliver2,3, C.M. Wilson4, Per Delsing1, and Jonas Bylander1 1Microtechnology and Nanoscience, Chalmers University of...Josephson Parametric Oscillator Philip Krantz1, Andreas Bengtsson1, Michaël Simoen1, Simon Gustavsson2, Vitaly Shumeiko1, W. D. Oliver2,3, C. M...BOX Qubit 10 mK 300 K Parametric resonator Fdc (b) 2.8 K 4-8 GHz HEMT R e so n at o r Q u b it P u m p (a) -40 dB -40 dB -20 dB-6 0 d B BPF A| | 2 B
Visual field changes after cataract extraction: the AGIS experience.
Koucheki, Behrooz; Nouri-Mahdavi, Kouros; Patel, Gitane; Gaasterland, Douglas; Caprioli, Joseph
2004-12-01
To test the hypothesis that cataract extraction in glaucomatous eyes improves overall sensitivity of visual function without affecting the size or depth of glaucomatous scotomas. Experimental study with no control group. One hundred fifty-eight eyes (of 140 patients) from the Advanced Glaucoma Intervention Study with at least two reliable visual fields within a year both before and after cataract surgery were included. Average mean deviation (MD), pattern standard deviation (PSD), and corrected pattern standard deviation (CPSD) were compared before and after cataract extraction. To evaluate changes in scotoma size, the number of abnormal points (P < .05) on the pattern deviation plot was compared before and after surgery. We described an index ("scotoma depth index") to investigate changes of scotoma depth after surgery. Mean values for MD, PSD, and CPSD were -13.2, 6.4, and 5.9 dB before and -11.9, 6.8, and 6.2 dB after cataract surgery (P < or = .001 for all comparisons). Mean (+/- SD) number of abnormal points on pattern deviation plot was 26.7 +/- 9.4 and 27.5 +/- 9.0 before and after cataract surgery, respectively (P = .02). Scotoma depth index did not change after cataract extraction (-19.3 vs -19.2 dB, P = .90). Cataract extraction caused generalized improvement of the visual field, which was most marked in eyes with less advanced glaucomatous damage. Although the enlargement of scotomas was statistically significant, it was not clinically meaningful. No improvement of sensitivity was observed in the deepest part of the scotomas.
780nm-range VCSEL array for laser printer system and other applications at Ricoh
NASA Astrophysics Data System (ADS)
Jikutani, Naoto; Itoh, Akihiro; Harasaka, Kazuhiro; Sasaki, Toshihide; Sato, Shunichi
2016-03-01
A 780 nm-range 40 channels vertical-cavity surface-emitting laser (VCSEL) array was developed as a writing light source for printers. A 15° off missoriented GaAs substrate, an aluminum-free GaInAsP/GaInP compressively-strained multiple quantum well and an anisotropic-shape transverse-mode filter were employed to control polarization characteristics. The anisotropic-shape transverse-mode filter also suppressed higher transverse-mode and enabled high-power single-mode operation. Thus, orthogonal-polarization suppression-ratio (OPSR) of over 22 dB and side-mode suppression-ratio (SMSR) of 30 dB were obtained at operation power of 3mW at same time for wide oxide-aperture range below 50 μm2. Moreover, a thermal resistance was reduced for 38% by increasing a thickness of high thermal conductivity layer (3λ/4-AlAs layer) near a cavity. By this structure, a peak-power increased to 1.3 times. Moreover, a power-fall caused by self-heating at pulse-rise was decreased to 10% and the one caused by a thermal-crosstalk between channels was decreased to 46%. The VCSEL array was mounted in a ceramic package with a tilted seal glass to prevent optical-crosstalk caused by other channels. Thus, we achieved stable-output and high-quality beam characteristics for long-duration pulse drive.
Skylab S-193 radar altimeter experiment analyses and results
NASA Technical Reports Server (NTRS)
Brown, G. S. (Editor)
1977-01-01
The design of optimum filtering procedures for geoid recovery is discussed. Statistical error bounds are obtained for pointing angle estimates using average waveform data. A correlation of tracking loop bandwidth with magnitude of pointing error is established. The impact of ocean currents and precipitation on the received power are shown to be measurable effects. For large sea state conditions, measurements of sigma 0 deg indicate a distinct saturation level of about 8 dB. Near-nadir less than 15 deg values of sigma 0 deg are also presented and compared with theoretical models. Examination of Great Salt Lake Desert scattering data leads to rejection of a previously hypothesized specularly reflecting surface. Pulse-to-pulse correlation results are in agreement with quasi-monochromatic optics theoretical predictions and indicate a means for estimating direction of pointing error. Pulse compression techniques for and results of estimating significant waveheight from waveform data are presented and are also shown to be in good agreement with surface truth data. A number of results pertaining to system performance are presented.
Novel modes and adaptive block scanning order for intra prediction in AV1
NASA Astrophysics Data System (ADS)
Hadar, Ofer; Shleifer, Ariel; Mukherjee, Debargha; Joshi, Urvang; Mazar, Itai; Yuzvinsky, Michael; Tavor, Nitzan; Itzhak, Nati; Birman, Raz
2017-09-01
The demand for streaming video content is on the rise and growing exponentially. Networks bandwidth is very costly and therefore there is a constant effort to improve video compression rates and enable the sending of reduced data volumes while retaining quality of experience (QoE). One basic feature that utilizes the spatial correlation of pixels for video compression is Intra-Prediction, which determines the codec's compression efficiency. Intra prediction enables significant reduction of the Intra-Frame (I frame) size and, therefore, contributes to efficient exploitation of bandwidth. In this presentation, we propose new Intra-Prediction algorithms that improve the AV1 prediction model and provide better compression ratios. Two (2) types of methods are considered: )1( New scanning order method that maximizes spatial correlation in order to reduce prediction error; and )2( New Intra-Prediction modes implementation in AVI. Modern video coding standards, including AVI codec, utilize fixed scan orders in processing blocks during intra coding. The fixed scan orders typically result in residual blocks with high prediction error mainly in blocks with edges. This means that the fixed scan orders cannot fully exploit the content-adaptive spatial correlations between adjacent blocks, thus the bitrate after compression tends to be large. To reduce the bitrate induced by inaccurate intra prediction, the proposed approach adaptively chooses the scanning order of blocks according to criteria of firstly predicting blocks with maximum number of surrounding, already Inter-Predicted blocks. Using the modified scanning order method and the new modes has reduced the MSE by up to five (5) times when compared to conventional TM mode / Raster scan and up to two (2) times when compared to conventional CALIC mode / Raster scan, depending on the image characteristics (which determines the percentage of blocks predicted with Inter-Prediction, which in turn impacts the efficiency of the new scanning method). For the same cases, the PSNR was shown to improve by up to 7.4dB and up to 4 dB, respectively. The new modes have yielded 5% improvement in BD-Rate over traditionally used modes, when run on K-Frame, which is expected to yield 1% of overall improvement.
NASA Astrophysics Data System (ADS)
Li, Yan-Ming; Liang, Zhen-Zhen; Song, Chun-Lei
2016-05-01
To compare the effect of 3 kinds of different materials on the hemostasis of puncture site after central venous catheterization. Method: A selection of 120 patients with peripheral central venous catheter chemotherapy in the Affiliated Hospital of our university from January 2014 to April 2015, Randomly divided into 3 groups, using the same specification (3.5cm × 2cm) alginate gelatin sponge and gauze dressing, 3 kinds of material compression puncture point, 3 groups of patients after puncture 24 h within the puncture point of local blood and the catheter after the catheter 72 h within the catheter maintenance costs. Result: (1) The local infiltration of the puncture point in the 24 h tube: The use of alginate dressing and gelatin sponge hemostatic effect is better than that of compression gauze. The difference was statistically significant (P <0.05). Compared with gelatin sponge and alginate dressing hemostatic effect, The difference was not statistically significant. (2) Tube maintenance cost: Puncture point using gelatin sponge, The local maintenance costs of the catheter within 72 h after insertion of the tube are lowest, compared with alginate dressing and gauze was significant (P<0.05). Conclusion: The choice of compression hemostasis material for the puncture site after PICC implantation, using gelatin sponge and gauze dressing is more effective and economic.
Li, Yu-Sang; Wang, Jun-Xian; Jia, Mei-Mei; Liu, Min; Li, Xiao-Jun; Tang, He-Bin
2012-01-01
As a traditional Chinese medicine, dragon's blood (DB) is widely used in treating various pains for thousands of years due to its potent anti-inflammatory and analgesic effects. In the present study, we observed that intragastric administration of DB at dosages of 0.14, 0.56, and 1.12 g/kg potently inhibited paw edema, hyperalgesia, cyclooxygenase-2 (COX-2) protein expression, or preprotachykinin-A mRNA expression in carrageenan-inflamed or sciatic nerve-injured (chronic constriction injury) rats, respectively. A short-term (15 s or 10 min) pre-exposure of cultured rat dorsal root ganglion (DRG) neurons to DB (0.3, 3, and 30 µg/ml) or its component cochinchinenin B (CB; 0.1, 1, and 10 µM) blocked capsaicin-evoked increases in both the intracellular calcium ion concentration and the substance P release. Moreover, a long-term (180 min) exposure of cultured rat DRG neurons to DB or CB significantly attenuated bradykinin-induced substance P release. These findings indicate that DB exerts anti-inflammatory and analgesic effects by blocking the synthesis and release of substance P through inhibition of COX-2 protein induction and intracellular calcium ion concentration. Therefore, DB may serve as a promising potent therapeutic agent for treatment of chronic pain, and its effective component CB might partly contribute to anti-inflammatory and analgesic effects.
Choi, Hojong; Woo, Park Chul; Yeom, Jung-Yeol; Yoon, Changhan
2017-01-01
A power MOSFET linearizer is proposed for a high-voltage power amplifier (HVPA) used in high-frequency pulse-echo instrumentation. The power MOSFET linearizer is composed of a DC bias-controlled series power MOSFET shunt with parallel inductors and capacitors. The proposed scheme is designed to improve the gain deviation characteristics of the HVPA at higher input powers. By controlling the MOSFET bias voltage in the linearizer, the gain reduction into the HVPA was compensated, thereby reducing the echo harmonic distortion components generated by the ultrasonic transducers. In order to verify the performance improvement of the HVPA implementing the power MOSFET linearizer, we measured and found that the gain deviation of the power MOSFET linearizer integrated with HVPA under 10 V DC bias voltage was reduced (−1.8 and −0.96 dB, respectively) compared to that of the HVPA without the power MOSFET linearizer (−2.95 and −3.0 dB, respectively) when 70 and 80 MHz, three-cycle, and 26 dBm input pulse waveforms are applied, respectively. The input 1-dB compression point (an index of linearity) of the HVPA with power MOSFET linearizer (24.17 and 26.19 dBm at 70 and 80 MHz, respectively) at 10 V DC bias voltage was increased compared to that of HVPA without the power MOSFET linearizer (22.03 and 22.13 dBm at 70 and 80 MHz, respectively). To further verify the reduction of the echo harmonic distortion components generated by the ultrasonic transducers, the pulse-echo responses in the pulse-echo instrumentation were compared when using HVPA with and without the power MOSFET linearizer. When three-cycle 26 dBm input power was applied, the second, third, fourth, and fifth harmonic distortion components of a 75 MHz transducer driven by the HVPA with power MOSFET linearizer (−48.34, −44.21, −48.34, and −46.56 dB, respectively) were lower than that of the HVPA without the power MOSFET linearizer (−45.61, −41.57, −45.01, and −45.51 dB, respectively). When five-cycle 20 dBm input power was applied, the second, third, fourth, and fifth harmonic distortions of the HVPA with the power MOSFET linearizer (−41.54, −41.80, −48.86, and −46.27 dB, respectively) were also lower than that of the HVPA without the power MOSFET linearizer (−25.85, −43.56, −49.04, and −49.24 dB, respectively). Therefore, we conclude that the power MOSFET linearizer could reduce gain deviation of the HVPA, thus reducing the echo signal harmonic distortions generated by the high-frequency ultrasonic transducers in pulse-echo instrumentation. PMID:28375165
Dibenzo[a,l]pyrene (DB[a1]P) is less prevalent in the environment but 100-200X more carcinogenic in rodents than benzo[a]pyrene (B[a]P) .B[a]P induces most of its adducts on G, whereas DB[a,1]P produces most its adducts on A. Using the Salmonella mutagenicity assay, we have exami...
Kılıç, D; Göksu, E; Kılıç, T; Buyurgan, C S
2018-05-01
The aim of this randomized cross-over study was to compare one-minute and two-minute continuous chest compressions in terms of chest compression only CPR quality metrics on a mannequin model in the ED. Thirty-six emergency medicine residents participated in this study. In the 1-minute group, there was no statistically significant difference in the mean compression rate (p=0.83), mean compression depth (p=0.61), good compressions (p=0.31), the percentage of complete release (p=0.07), adequate compression depth (p=0.11) or the percentage of good rate (p=51) over the four-minute time period. Only flow time was statistically significant among the 1-minute intervals (p<0.001). In the 2-minute group, the mean compression depth (p=0.19), good compression (p=0.92), the percentage of complete release (p=0.28), adequate compression depth (p=0.96), and the percentage of good rate (p=0.09) were not statistically significant over time. In this group, the number of compressions (248±31 vs 253±33, p=0.01) and mean compression rates (123±15 vs 126±17, p=0.01) and flow time (p=0.001) were statistically significant along the two-minute intervals. There was no statistically significant difference in the mean number of chest compressions per minute, mean chest compression depth, the percentage of good compressions, complete release, adequate chest compression depth and percentage of good compression between the 1-minute and 2-minute groups. There was no statistically significant difference in the quality metrics of chest compressions between 1- and 2-minute chest compression only groups. Copyright © 2017 Elsevier Inc. All rights reserved.
Validation of air displacement plethysmography for assessing body composition.
Wagner, D R; Heyward, V H; Gibson, A L
2000-07-01
The purpose of this study was to verify the validity of an air displacement plethysmography device (Bod Pod) for estimating body density (Db). The Db from the Bod Pod (DbBP) was compared with the Db from hydrostatic weighing (DbHW) at residual lung volume in a heterogeneous sample of 30 black men who varied in age (32.0 +/- 7.7 yr), height (180.3 +/- 7.5 cm), body mass (84.2 +/- 15.0 kg), body fatness (16.1 +/- 7.5%), and self-reported physical activity level and socioeconomic status. The Db for each method was converted to relative body fat (%BF) using race-specific conversion formulas and subsequently compared with %BF obtained from dual-energy x-ray absorptiometry (%BFDXA). Linear regression, using DbHW as the dependent variable and DbBP as the predictor, produced an R2 = 0.84 and SEE = 0.00721 g x cc(-1). However, the mean difference between the two methods (0.00450 +/- 0.00718 g x cc(-1) was significant (P < 0.01). The Bod Pod underestimated the Db of 73% of the sample. The %BF estimates from the Bod Pod, HW, and DXA differed significantly (P < 0.01). The average %BFBP (17.7 +/- 7.4%) was significantly greater than %BFHW (15.8 +/- 7.5%) and %BFDXA (16.1 +/- 7.5%); however, there was no significant difference between %BFHW and %BFDXA. The Bod Pod significantly and systematically underestimated Db, resulting in an overestimation of %BF. More cross-validation research is needed before recommending the Bod Pod as a reference method.
NASA Astrophysics Data System (ADS)
Viswanathan, E.; Sundareswari, M.; Jayalakshmi, D. S.; Manjula, M.; Krishnaveni, S.
2017-09-01
First principles calculations are carried out in order to analyze the structural, electronic, mechanical, thermal and optical properties of BP and BAs compounds by ternary alloying with nitrogen namely B(P,As)1-xNx (x = 0.25, 0.5, 0.75) alloys at ambient condition. Thereby we report the mechanical and thermal properties of B(P,As)1-xNx (x = 0.25, 0.5, 0.75) alloys namely bulk modulus, shear modulus, Young's modulus, hardness, ductile-brittle nature, elastic wave velocity, Debye temperature, melting point, etc.; optical properties of B(P)1-xNx (x = 0.25, 0.5, 0.75) and B(As)1-xNx (x = 0.25, 0.75) alloys namely the dielectric function of real and imaginary part, refractive index, extinction coefficient and reflectivity and the hardness profile of the parent compounds BP and BAs under compression. The charge density plot, density of states histograms and band structures are plotted and discussed for all the ternary alloys of the present study. The calculated results agree very well with the available literature. Analysis of the present study reveals that the ternary alloy combinations namely BP.25N.75 and BAs.25N.75 could be superhard materials; hardness of BP and BAs increases with compression.
Shock-adiabatic to quasi-isentropic compression of warm dense helium up to 150 GPa
NASA Astrophysics Data System (ADS)
Zheng, J.; Chen, Q. F.; Gu, Y. J.; Li, J. T.; Li, Z. G.; Li, C. J.; Chen, Z. Y.
2017-06-01
Multiple reverberation compression can achieve higher pressure, higher temperature, but lower entropy. It is available to provide an important validation for the elaborate and wider planetary models and simulate the inertial confinement fusion capsule implosion process. In the work, we have developed the thermodynamic and optical properties of helium from shock-adiabatic to quasi-isentropic compression by means of a multiple reverberation technique. By this technique, the initial dense gaseous helium was compressed to high pressure and high temperature and entered the warm dense matter (WDM) region. The experimental equation of state (EOS) of WDM helium in the pressure-density-temperature (P-ρ -T) range of 1 -150 GPa , 0.1 -1.1 g c m-3 , and 4600-24 000 K were measured. The optical radiations emanating from the WDM helium were recorded, and the particle velocity profiles detecting from the sample/window interface were obtained successfully up to 10 times compression. The optical radiation results imply that dense He has become rather opaque after the 2nd compression with a density of about 0.3 g c m-3 and a temperature of about 1 eV. The opaque states of helium under multiple compression were analyzed by the particle velocity measurements. The multiple compression technique could efficiently enhanced the density and the compressibility, and our multiple compression ratios (ηi=ρi/ρ0,i =1 -10 ) of helium are greatly improved from 3.5 to 43 based on initial precompressed density (ρ0) . For the relative compression ratio (ηi'=ρi/ρi -1) , it increases with pressure in the lower density regime and reversely decreases in the higher density regime, and a turning point occurs at the 3rd and 4th compression states under the different loading conditions. This nonmonotonic evolution of the compression is controlled by two factors, where the excitation of internal degrees of freedom results in the increasing compressibility and the repulsive interactions between the particles results in the decreasing compressibility at the onset of electron excitation and ionization. In the P-ρ -T contour with the experiments and the calculations, our multiple compression states from insulating to semiconducting fluid (from transparent to opaque fluid) are illustrated. Our results give an elaborate validation of EOS models and have applications for planetary and stellar opaque atmospheres.
Patino, Cecilia M.; Varma, Rohit; Azen, Stanley P.; Conti, David V.; Nichol, Michael B.; McKean-Cowdin, Roberta
2010-01-01
Purpose To assess the impact of change in visual field (VF) on change in health related quality of life (HRQoL) at the population level. Design Prospective cohort study Participants 3,175 Los Angles Latino Eye Study (LALES) participants Methods Objective measures of VF and visual acuity and self-reported HRQoL were collected at baseline and 4-year follow-up. Analysis of covariance was used to evaluate mean differences in change of HRQoL across severity levels of change in VF and to test for effect modification by covariates. Main outcome measures General and vision-specific HRQoL. Results Of 3,175 participants, 1430 (46%) showed a change in VF (≥1 decibel [dB]) and 1651, 1715 (54%) reported a clinically important change (≥5 points) in vision-specific HRQoL. Progressive worsening and improvement in the VF were associated with increasing losses and gains in vision-specific HRQoL for the composite score and 10 of its 11 subscales (all Ptrends<0.05). Losses in VF > 5 dB and gains > 3 dB were associated with clinically meaningful losses and gains in vision-specific HRQoL, respectively. Areas of vision-specific HRQoL most affected by greater losses in VF were driving, dependency, role-functioning, and mental health. The effect of change in VF (loss or gain) on mean change in vision-specific HRQoL varied by level of baseline vision loss (in visual field and/or visual acuity) and by change in visual acuity (all P-interactions<0.05). Those with moderate/severe VF loss at baseline and with a > 5 dB loss in visual field during the study period had a mean loss of vision-specific HRQoL of 11.3 points, while those with no VF loss at baseline had a mean loss of 0.97 points Similarly, with a > 5 dB loss in VF and baseline visual acuity impairment (mild/severe) there was a loss in vision-specific HRQoL of 10.5 points, whereas with no visual acuity impairment at baseline there was a loss of vision-specific HRQoL of 3.7 points. Conclusion Both losses and gains in VF produce clinically meaningful changes in vision-specific HRQoL. In the presence of pre-existing vision loss (VF and visual acuity), similar levels of visual field change produce greater losses in quality of life. PMID:21458074
Cardiopulmonary resuscitation by chest compression alone or with mouth-to-mouth ventilation.
Hallstrom, A; Cobb, L; Johnson, E; Copass, M
2000-05-25
Despite extensive training of citizens of Seattle in cardiopulmonary resuscitation (CPR), bystanders do not perform CPR in almost half of witnessed cardiac arrests. Instructions in chest compression plus mouth-to-mouth ventilation given by dispatchers over the telephone can require 2.4 minutes. In experimental studies, chest compression alone is associated with survival rates similar to those with chest compression plus mouth-to-mouth ventilation. We conducted a randomized study to compare CPR by chest compression alone with CPR by chest compression plus mouth-to-mouth ventilation. The setting of the trial was an urban, fire-department-based, emergency-medical-care system with central dispatching. In a randomized manner, telephone dispatchers gave bystanders at the scene of apparent cardiac arrest instructions in either chest compression alone or chest compression plus mouth-to-mouth ventilation. The primary end point was survival to hospital discharge. Data were analyzed for 241 patients randomly assigned to receive chest compression alone and 279 assigned to chest compression plus mouth-to-mouth ventilation. Complete instructions were delivered in 62 percent of episodes for the group receiving chest compression plus mouth-to-mouth ventilation and 81 percent of episodes for the group receiving chest compression alone (P=0.005). Instructions for compression required 1.4 minutes less to complete than instructions for compression plus mouth-to-mouth ventilation. Survival to hospital discharge was better among patients assigned to chest compression alone than among those assigned to chest compression plus mouth-to-mouth ventilation (14.6 percent vs. 10.4 percent), but the difference was not statistically significant (P=0.18). The outcome after CPR with chest compression alone is similar to that after chest compression with mouth-to-mouth ventilation, and chest compression alone may be the preferred approach for bystanders inexperienced in CPR.
Compressed liquid densities, saturated liquid densities, and vapor pressures of 1,1-difluoroethane
DOE Office of Scientific and Technical Information (OSTI.GOV)
Defibaugh, D.R.; Morrison, G.
1996-05-01
The compressed liquid densities and vapor pressures of 1,1-difluoroethane (HFC-152a) have been measured, correlated, and compared with other data. The liquid densities were measured with a combined standard uncertainty of {+-}0.05% using a vibrating tube densimeter over a temperature range of 243 K to 371 K and at pressures from near the saturated vapor pressure to 6,500 kPa; thus the data extend nearly to the critical point ({Tc} = 386.41 K and P{sub c} = 4514.7 kPa). The vapor pressures were measured with a combined standard uncertainty of {+-}0.02% using a stainless steel ebulliometer in the temperature range from 280more » K to 335 K. Saturated liquid densities were calculated by extrapolating the compressed liquid isotherms to the saturation pressure.« less
Tang, Yijin; Liu, Zhi; Ding, Shuang; Lin, Chin H; Cai, Yuqin; Rodriguez, Fabian A; Sayer, Jane M; Jerina, Donald M; Amin, Shantu; Broyde, Suse; Geacintov, Nicholas E
2012-12-04
The most potent tumorigen identified among the polycyclic aromatic hydrocarbons (PAH) is the nonplanar fjord region dibenzo[a,l]pyrene (DB[a,l]P). It is metabolically activated in vivo through the widely studied diol epoxide (DE) pathway to form covalent adducts with DNA bases, predominantly guanine and adenine. The (+)-11S,12R,13R,14S DE enantiomer forms adducts via its C14 position with the exocyclic amino group of guanine. Here, we present the first nuclear magnetic resonance solution structure of a DB[a,l]P-derived adduct, the 14R-(+)-trans-anti-DB[a,l]P-N(2)-dG (DB[a,l]P-dG) lesion in double-stranded DNA. In contrast to the stereochemically identical benzo[a]pyrene-derived N(2)-dG adduct (B[a]P-dG) in which the B[a]P rings reside in the B-DNA minor groove on the 3'-side of the modifed deoxyguanosine, in the DB[a,l]P-derived adduct the DB[a,l]P rings intercalate into the duplex on the 3'-side of the modified base from the sterically crowded minor groove. Watson-Crick base pairing of the modified guanine with the partner cytosine is broken, but these bases retain some stacking with the bulky DB[a,l]P ring system. This new theme in PAH DE-DNA adduct conformation differs from (1) the classical intercalation motif in which Watson-Crick base pairing is intact at the lesion site and (2) the base-displaced intercalation motif in which the damaged base and its partner are extruded from the helix. The structural considerations that lead to the intercalated conformation of the DB[a,l]P-dG lesion in contrast to the minor groove alignment of the B[a]P-dG adduct, and the implications of the DB[a,l]P-dG conformational motif for the recognition of such DNA lesions by the human nucleotide excision repair apparatus, are discussed.
[Comparing the ranges of defect measured with standard white on white and Pulsar perimetries].
González de la Rosa, M; González-Hernández, M; García-Feijoo, J; Sánchez Méndez, M; García-Sánchez, J
2011-04-01
Normal thresholds on Pulsar perimetry fall faster than those of standard perimetry in the peripheral visual field. Two related studies were performed. Firstly, the frequency distributions of glaucoma defects on standard automated perimetry (SAP) and the relationship of the centre and periphery (Study A) were studied first, followed by an attempt to establish the limits of pulsar perimetry (Study B). A: frequency of defects was calculated in 78.663 SAP perimetries (G1-TOP, Octopus 1-2-3, Haag-Streit). Study B: 204 eyes with mean defect (MD-SAP) lower than 9 dB were examined 8.92 ± 4.19 times with SAP (TOP-32, Octopus 311) and temporal modulation perimetry (T30W, Pulsar Perimeter, Haag-Streit). Study A: 50.7% of the SAP examinations showed MD values lower than 9 dB and 32.7% bellow 6 dB. The MD correlation of the central 20° with the MD of the most peripheral points was r=0.933. Study B: in cases with MD-TOP-32 lower than 6 dB, SAP had the maximum possibility of detecting defect in 0.02% of points and Pulsar in 0.29%. In subjects with MD-TOP-32 between 6 and 9 dB frequencies were 0.38% in SAP and 3.5% in Pulsar (5.1% for eccentricities higher than 20°). Pulsar allows detecting defects, without range limitations, in the initial half of SAP frequencies expected on glaucoma patients. In order to study the progression of deeper defects the examination should focus on the central points, where the dynamic range of both systems is more equivalent. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
Li, Jun; He, Wang; Liao, Bo; Yang, Jingyue
2015-07-31
This study evaluated the association between free fatty acid (FFA), ROS generation, mitochondrial dysfunction and bone mineral density (BMD) in type 2 diabetic patients and investigated the molecular mechanism. db/db and high fat (HF)-fed mice were treated by Etomoxir, an inhibitor of CPT1, MitoQ, and PFT-α, an inhibitor of P53. Bone metabolic factors were assessed and BMSCs were isolated and induced to osteogenic differentiation. FFA, lipid peroxidation and mtDNA copy number were correlated with BMD in T2DM patients. Etomoxir, MitoQ and PFT-α significantly inhibited the decrease of BMD and bone breaking strength in db/db and HF-fed mice and suppressed the reduction of BMSCs-differentiated osteoblasts. Etomoxir and MitoQ, but not PFT-α, inhibited the increase of mitochondrial ROS generation in db/db and HF-fed mice and osteoblasts. In addition, Etomoxir, MitoQ and PFT-α significantly inhibited mitochondrial dysfunction in osteoblasts. Moreover, mitochondrial apoptosis was activated in osteoblasts derived from db/db and HF-fed mice, which was inhibited by Etomoxir, MitoQ and PFT-α. Furthermore, mitochondrial accumulation of P53 recruited Bax and initiated molecular events of apoptotic events. These results demonstrated that fatty acid oxidation resulted in ROS generation, activating P53/Bax-mediated mitochondrial apoptosis, leading to reduction of osteogenic differentiation and bone loss in T2DM.
NASA Astrophysics Data System (ADS)
Ligeret, V.; Vermersch, F.-J.; Bansropun, S.; Lecomte, M.; Calligaro, M.; Parillaud, O.; Krakowski, M.
2017-11-01
Atomic clocks will be used in the future European positioning system Galileo. Among them, the optically pumped clocks provide a better alternative with comparable accuracy for a more compact system. For these systems, diode lasers emitting at 852nm are strategic components. The laser in a conventional bench for atomic clocks presents disadvantages for spatial applications. A better approach would be to realise a system based on a distributed-feedback laser (DFB). We have developed the technological foundations of such lasers operating at 852nm. These include an Al free active region, a single spatial mode ridge waveguide and a DFB structure. The device is a separate confinement heterostructure with a GaInP large optical cavity and a single compressive strained GaInAsP quantum well. The broad area laser diodes are characterised by low internal losses (<3cm -1 ), a high internal efficiency (94%) and a low transparency current density (100A/cm2). For an AR-HR coated ridge Fabry Perot laser, we obtain a power of 230mW with M2=1.3. An optical power of 150mW was obtained at 854nm wavelength, 20°C for AR-HR coated devices. We obtain a single spatial mode emission with M2=1.21 and a SMSR over 30dB, both at 150mW. DFB Lasers at 852.12nm, corresponding to the D2 caesium transition, were then realised with a power of 40mW, 37°C for uncoated devices. The SMSR is over 30dB and the M2=1.33 at 40mW. Furthermore, the preliminary results of the linewidth obtained with a Fabry Perot interferometer give a value of less than 2MHz.
[Manual trigger point therapy of shoulder pain : Randomized controlled study of effectiveness].
Sohns, S; Schnieder, K; Licht, G; von Piekartz, H
2016-12-01
Although chronic shoulder pain is highly prevalent and myofascial trigger points (mTrP) are thought to be found in the majority of patients with shoulder complaints, the influence on the pain mechanism remains unclear. There are only very few controlled clinical studies on the effects of manual trigger point compression therapy. This randomized controlled trial (RCT) compared the short-term effects of manual trigger point compression therapy (n = 6) with manual sham therapy (n = 6) in patients with unilateral shoulder pain due to myofascial syndrome (MFS). The measurement data were collected before and after two sessions of therapy. Pressure pain thresholds (PPT) of mTrP and symmetrically located points on the asymptomatic side were measured together with neutral points in order to detect a potential unilateral or generalized hyperalgesia. Additionally, the pain was assessed on a visual analog scale (VAS) at rest and during movement and the neck disability index (NDI) and disabilities of the arm, shoulder and hand (DASH) questionnaires were also completed and evaluated. Both treatment modalities led to a significant improvement; however, the manual trigger point compression therapy was significantly more effective in comparison to sham therapy, as measured by different parameters. The significant improvement of PPT values in the interventional group even at sites that were not directly treated, indicates central mechanisms in pain threshold modulation induced by manual compression therapy. The weaker but still measurable effects of sham therapy might be explained by the sham modality being a hands on technique or by sufficient stimulation of the trigger point region during the diagnostics and PPT measurements.
Compressed sensing system considerations for ECG and EMG wireless biosensors.
Dixon, Anna M R; Allstot, Emily G; Gangopadhyay, Daibashish; Allstot, David J
2012-04-01
Compressed sensing (CS) is an emerging signal processing paradigm that enables sub-Nyquist processing of sparse signals such as electrocardiogram (ECG) and electromyogram (EMG) biosignals. Consequently, it can be applied to biosignal acquisition systems to reduce the data rate to realize ultra-low-power performance. CS is compared to conventional and adaptive sampling techniques and several system-level design considerations are presented for CS acquisition systems including sparsity and compression limits, thresholding techniques, encoder bit-precision requirements, and signal recovery algorithms. Simulation studies show that compression factors greater than 16X are achievable for ECG and EMG signals with signal-to-quantization noise ratios greater than 60 dB.
Przyborowski, Kamil; Wojewoda, Marta; Sitek, Barbara; Zakrzewska, Agnieszka; Kij, Agnieszka; Wandzel, Krystyna; Zoladz, Jerzy Andrzej; Chlopicki, Stefan
2015-01-01
1-Methylnicotinamide (MNA), which was initially considered to be a biologically inactive endogenous metabolite of nicotinamide, has emerged as an anti-thrombotic and anti-inflammatory agent with the capacity to release prostacyclin (PGI2). In the present study, we characterized the effects of MNA on exercise capacity and the endothelial response to exercise in diabetic mice. Eight-week-old db/db mice were untreated or treated with MNA for 4 weeks (100 mg·kg-1), and their exercise capacity as well as NO- and PGI2-dependent response to endurance running were subsequently assessed. MNA treatment of db/db mice resulted in four-fold and three-fold elevation of urine concentrations of MNA and its metabolites (Met-2PY + Met-4PY), respectively (P<0.01), but did not affect HbA1c concentration, fasting glucose concentration or lipid profile. However, insulin sensitivity was improved (P<0.01). In MNA-treated db/db mice, the time to fatigue for endurance exercise was significantly prolonged (P<0.05). Post-exercise Δ6-keto-PGF1α (difference between mean concentration in the sedentary and exercised groups) tended to increase, and post-exercise leukocytosis was substantially reduced in MNA-treated animals. In turn, the post-exercise fall in plasma concentration of nitrate was not affected by MNA. In conclusion, we demonstrated for the first time that MNA improves endurance exercise capacity in mice with diabetes, and may also decrease the cardiovascular risk of exercise.
Tang, Yijin; Liu, Zhi; Ding, Shuang; Lin, Chin H.; Cai, Yuqin; Rodriguez, Fabian A.; Sayer, Jane M.; Jerina, Donald M.; Amin, Shantu; Broyde, Suse; Geacintov, Nicholas E.
2012-01-01
The most potent tumorigen identified among the polycyclic aromatic hydrocarbons (PAH) is the non-planar fjord region dibenzo[a,l]pyrene (DB[a,l]P). It is metabolically activated in vivo through the widely-studied diol epoxide (DE) pathway to form covalent adducts with DNA bases, predominantly guanine and adenine. The (+)-11S,12R,13R,14S DE enantiomer forms adducts via its C14-position with the exocyclic amino group of guanine. Here, we present the first NMR solution structure of a DB[a,l]P-derived adduct, the 14R (+)-trans-anti-DB[a,l]P–N2-dG (DB[a,l]P-dG) lesion in double-stranded DNA. In contrast to the stereochemically identical benzo[a]pyrene-derived N2-dG adduct (B[a]P-dG) in which the B[a]P rings reside in the B-DNA minor groove on the 3’-side of the modifed deoxyguanosine, in the DB[a,l]P-derived adduct the DB[a,l]P rings intercalate into the duplex on the 3’-side of the modified base from the sterically crowded minor groove. Watson-Crick base pairing of the modified guanine with the partner cytosine is broken, but these bases retain some stacking with the bulky DB[a,l]P ring system. This new theme in PAH DE - DNA adduct conformation differs from: (1) the classical intercalation motif where Watson-Crick base-pairing is intact at the lesion site, and (2) the base-displaced intercalation motif in which the damaged base and its partner are extruded from the helix . The structural considerations that lead to the intercalated conformation of the DB[a,l]P-dG lesion in contrast to the minor groove alignment of the B[a]P-dG adduct, and the implications of the DB[a,l]P-dG conformational motif for the recognition of such DNA lesions by the human nucleotide excision repair apparatus, are discussed. PMID:23121427
Optimal color coding for compression of true color images
NASA Astrophysics Data System (ADS)
Musatenko, Yurij S.; Kurashov, Vitalij N.
1998-11-01
In the paper we present the method that improves lossy compression of the true color or other multispectral images. The essence of the method is to project initial color planes into Karhunen-Loeve (KL) basis that gives completely decorrelated representation for the image and to compress basis functions instead of the planes. To do that the new fast algorithm of true KL basis construction with low memory consumption is suggested and our recently proposed scheme for finding optimal losses of Kl functions while compression is used. Compare to standard JPEG compression of the CMYK images the method provides the PSNR gain from 0.2 to 2 dB for the convenient compression ratios. Experimental results are obtained for high resolution CMYK images. It is demonstrated that presented scheme could work on common hardware.
Additivity of nonsimultaneous masking for short Gaussian-shaped sinusoids.
Laback, Bernhard; Balazs, Peter; Necciari, Thibaud; Savel, Sophie; Ystad, Solvi; Meunier, Sabine; Kronland-Martinet, Richard
2011-02-01
The additivity of nonsimultaneous masking was studied using Gaussian-shaped tone pulses (referred to as Gaussians) as masker and target stimuli. Combinations of up to four temporally separated Gaussian maskers with an equivalent rectangular bandwidth of 600 Hz and an equivalent rectangular duration of 1.7 ms were tested. Each masker was level-adjusted to produce approximately 8 dB of masking. Excess masking (exceeding linear additivity) was generally stronger than reported in the literature for longer maskers and comparable target levels. A model incorporating a compressive input/output function, followed by a linear summation stage, underestimated excess masking when using an input/output function derived from literature data for longer maskers and comparable target levels. The data could be predicted with a more compressive input/output function. Stronger compression may be explained by assuming that the Gaussian stimuli were too short to evoke the medial olivocochlear reflex (MOCR), whereas for longer maskers tested previously the MOCR caused reduced compression. Overall, the interpretation of the data suggests strong basilar membrane compression for very short stimuli.
NASA Technical Reports Server (NTRS)
Weber, W. J., III; Stanton, P. H.; Sumida, J. T.
1978-01-01
A bandwidth compressive modem making use of multi-amplitude minimum shift keying (MAMSK) has been designed and implemented in a laboratory environment at microwave frequencies. This system achieves a substantial bandwidth reduction over binary PSK and operates within 0.5 dB of theoretical performance. A number of easily implemented microwave transmitters have been designed to generate the required set of 16 signals. The receiver has been designed to work at 1 Mbit/s and contains the necessary phase tracking, AGC, and symbol synchronization loops as well as a lock detector, SNR estimator and provisions for differential decoding. This paper describes this entire system and presents the experimental results.
Park, Chan Hum; Yokozawa, Takako; Noh, Jeong Sook
2014-08-01
This study was conducted to examine whether oligonol, a low-molecular-weight polyphenol derived from lychee fruit, has an ameliorative effect on diabetes-induced alterations, such as advanced glycation end product (AGE) formation or apoptosis in the kidneys of db/db mice with type 2 diabetes. Oligonol [10 or 20 mg/(kg body weight · d), orally] was administered every day for 8 wk to prediabetic db/db mice, and its effect was compared with vehicle-treated db/db and normal control mice (m/m). The administration of oligonol decreased the elevated renal glucose concentrations and reactive oxygen species in db/db mice (P < 0.05). The increased serum urea nitrogen and creatinine concentrations, which reflect renal dysfunction in db/db mice, were substantially lowered by oligonol. Oligonol reduced renal protein expression of NAD(P)H oxidase subunits (p22 phagocytic oxidase and NAD(P)H oxidase-4), AGEs (except for pentosidine), and c-Jun N-terminal kinase B-targeting proinflammatory tumor necrosis factor-α (P < 0.05). Oligonol improved the expressions of antiapoptotic [B-cell lymphoma protein 2 (Bcl-2) and survivin] and proapoptotic [Bcl-2-associated X protein, cytochrome c, and caspase-3] proteins in the kidneys of db/db mice (P < 0.05). In conclusion, these results provide important evidence that oligonol exhibits a pleiotropic effect on AGE formation and apoptosis-related variables, representing renoprotective effects against the development of diabetic complications in db/db mice with type 2 diabetes. © 2014 American Society for Nutrition.
Moore, Johanna C; Lamhaut, Lionel; Hutin, Alice; Dodd, Kenneth W; Robinson, Aaron E; Lick, Michael C; Salverda, Bayert J; Hinke, Mason B; Labarere, José; Debaty, Guillaume; Segal, Nicolas
2017-10-01
The purpose of this study was to examine continuous oxygen insufflation (COI) in a swine model of cardiac arrest. The primary hypothesis was COI during standard CPR (S-CPR) should result in higher intrathoracic pressure (ITP) during chest compression and lower ITP during decompression versus S-CPR alone. These changes with COI were hypothesized to improve hemodynamics. The second hypothesis was that changes in ITP with S-CPR+COI would result in superior hemodynamics compared with active compression decompression (ACD) + impedance threshold device (ITD) CPR, as this method primarily lowers ITP during chest decompression. After 6min of untreated ventricular fibrillation, S-CPR was initiated in 8 female swine for 4min, then 3min of S-CPR+COI, then 3min of ACD+ITD CPR, then 3min of S-CPR+COI. ITP and hemodynamics were continuously monitored. During S-CPR+COI, ITP was always positive during the CPR compression and decompression phases. ITP compression values with S-CPR+COI versus S-CPR alone were 5.5±3 versus 0.2±2 (p<0.001) and decompression values were 2.8±2 versus -1.3±2 (p<0.001), respectively. With S-CPR+COI versus ACD+ITD the ITP compression values were 5.5±3 versus 1.5±2 (p<0.01) and decompression values were 2.8±2 versus -4.7±3 (p<0.001), respectively. COI during S-CPR created a continuous positive pressure in the airway during both the compression and decompression phase of CPR. At no point in time did COI generate a negative intrathoracic pressures during CPR in this swine model of cardiac arrest. Copyright © 2017 Elsevier B.V. All rights reserved.
New numerical solutions of three-dimensional compressible hydrodynamic convection. [in stars
NASA Technical Reports Server (NTRS)
Hossain, Murshed; Mullan, D. J.
1990-01-01
Numerical solutions of three-dimensional compressible hydrodynamics (including sound waves) in a stratified medium with open boundaries are presented. Convergent/divergent points play a controlling role in the flows, which are dominated by a single frequency related to the mean sound crossing time. Superposed on these rapid compressive flows, slower eddy-like flows eventually create convective transport. The solutions contain small structures stacked on top of larger ones, with vertical scales equal to the local pressure scale heights, H sub p. Although convective transport starts later in the evolution, vertical scales of H sub p are apparently selected at much earlier times by nonlinear compressive effects.
Optimal Compression Methods for Floating-point Format Images
NASA Technical Reports Server (NTRS)
Pence, W. D.; White, R. L.; Seaman, R.
2009-01-01
We report on the results of a comparison study of different techniques for compressing FITS images that have floating-point (real*4) pixel values. Standard file compression methods like GZIP are generally ineffective in this case (with compression ratios only in the range 1.2 - 1.6), so instead we use a technique of converting the floating-point values into quantized scaled integers which are compressed using the Rice algorithm. The compressed data stream is stored in FITS format using the tiled-image compression convention. This is technically a lossy compression method, since the pixel values are not exactly reproduced, however all the significant photometric and astrometric information content of the image can be preserved while still achieving file compression ratios in the range of 4 to 8. We also show that introducing dithering, or randomization, when assigning the quantized pixel-values can significantly improve the photometric and astrometric precision in the stellar images in the compressed file without adding additional noise. We quantify our results by comparing the stellar magnitudes and positions as measured in the original uncompressed image to those derived from the same image after applying successively greater amounts of compression.
High-Throughput Detection of Bacillus Anthracis Spores using Peptide-Conjugated Nano/Micro-Beads
2006-07-26
natto was a lab-stock isolated from natto . Expertise with B. anthracis ∆Sterne (pXO1-, pXO2-) and B. anthracis Sterne 34F2 (pXO1+, pXO2-) were...spore-peptide-Qdot complexes were analyzed by FACS. We found that BA1 peptide did not bind to B. subtilis DB104, B. subtilis natto and B. cereus...subtilis DB104, B. subtilis natto and B. cereus used as other more negative controls did not show fluorescence (data not shown). We then examined the
Effect of Pointing Error on the BER Performance of an Optical CDMA FSO Link with SIK Receiver
NASA Astrophysics Data System (ADS)
Nazrul Islam, A. K. M.; Majumder, S. P.
2017-12-01
An analytical approach is presented for an optical code division multiple access (OCDMA) system over free space optical (FSO) channel considering the effect of pointing error between the transmitter and the receiver. Analysis is carried out with an optical sequence inverse keying (SIK) correlator receiver with intensity modulation and direct detection (IM/DD) to find the bit error rate (BER) with pointing error. The results are evaluated numerically in terms of signal-to-noise plus multi-access interference (MAI) ratio, BER and power penalty due to pointing error. It is noticed that the OCDMA FSO system is highly affected by pointing error with significant power penalty at a BER of 10-6 and 10-9. For example, penalty at BER 10-9 is found to be 9 dB corresponding to normalized pointing error of 1.4 for 16 users with processing gain of 256 and is reduced to 6.9 dB when the processing gain is increased to 1,024.
NASA Astrophysics Data System (ADS)
Starosolski, Roman
2016-07-01
Reversible denoising and lifting steps (RDLS) are lifting steps integrated with denoising filters in such a way that, despite the inherently irreversible nature of denoising, they are perfectly reversible. We investigated the application of RDLS to reversible color space transforms: RCT, YCoCg-R, RDgDb, and LDgEb. In order to improve RDLS effects, we propose a heuristic for image-adaptive denoising filter selection, a fast estimator of the compressed image bitrate, and a special filter that may result in skipping of the steps. We analyzed the properties of the presented methods, paying special attention to their usefulness from a practical standpoint. For a diverse image test-set and lossless JPEG-LS, JPEG 2000, and JPEG XR algorithms, RDLS improves the bitrates of all the examined transforms. The most interesting results were obtained for an estimation-based heuristic filter selection out of a set of seven filters; the cost of this variant was similar to or lower than the transform cost, and it improved the average lossless JPEG 2000 bitrates by 2.65% for RDgDb and by over 1% for other transforms; bitrates of certain images were improved to a significantly greater extent.
Is complex signal processing for bone conduction hearing aids useful?
Kompis, Martin; Kurz, Anja; Pfiffner, Flurin; Senn, Pascal; Arnold, Andreas; Caversaccio, Marco
2014-05-01
To establish whether complex signal processing is beneficial for users of bone anchored hearing aids. Review and analysis of two studies from our own group, each comparing a speech processor with basic digital signal processing (either Baha Divino or Baha Intenso) and a processor with complex digital signal processing (either Baha BP100 or Baha BP110 power). The main differences between basic and complex signal processing are the number of audiologist accessible frequency channels and the availability and complexity of the directional multi-microphone noise reduction and loudness compression systems. Both studies show a small, statistically non-significant improvement of speech understanding in quiet with the complex digital signal processing. The average improvement for speech in noise is +0.9 dB, if speech and noise are emitted both from the front of the listener. If noise is emitted from the rear and speech from the front of the listener, the advantage of the devices with complex digital signal processing as opposed to those with basic signal processing increases, on average, to +3.2 dB (range +2.3 … +5.1 dB, p ≤ 0.0032). Complex digital signal processing does indeed improve speech understanding, especially in noise coming from the rear. This finding has been supported by another study, which has been published recently by a different research group. When compared to basic digital signal processing, complex digital signal processing can increase speech understanding of users of bone anchored hearing aids. The benefit is most significant for speech understanding in noise.
Litton, Edward; Elliott, Rosalind; Thompson, Kelly; Watts, Nicola; Seppelt, Ian; Webb, Steven A R
2017-06-01
To use clinically accessible tools to determine unit-level and individual patient factors associated with sound levels and sleep disruption in a range of representative ICUs. A cross-sectional, observational study. Australian and New Zealand ICUs. All patients 16 years or over occupying an ICU bed on one of two Point Prevalence study days in 2015. Ambient sound was measured for 1 minute using an application downloaded to a personal mobile device. Bedside nurses also recorded the total time and number of awakening for each patient overnight. The study included 539 participants with sound level recorded using an application downloaded to a personal mobile device from 39 ICUs. Maximum and mean sound levels were 78 dB (SD, 9) and 62 dB (SD, 8), respectively. Maximum sound levels were higher in ICUs with a sleep policy or protocol compared with those without maximum sound levels 81 dB (95% CI, 79-83) versus 77 dB (95% CI, 77-78), mean difference 4 dB (95% CI, 0-2), p < 0.001. There was no significant difference in sound levels regardless of single room occupancy, mechanical ventilation status, or illness severity. Clinical nursing staff in all 39 ICUs were able to record sleep assessment in 15-minute intervals. The median time awake and number of prolonged disruptions were 3 hours (interquartile range, 1-4) and three (interquartile range, 2-5), respectively. Across a large number of ICUs, patients were exposed to high sound levels and substantial sleep disruption irrespective of factors including previous implementation of a sleep policy. Sound and sleep measurement using simple and accessible tools can facilitate future studies and could feasibly be implemented into clinical practice.
1977-02-07
CHG12 1 Dr.%VC 8 DB ILA8 DC1II 29 FTLE: FDS TAPIRWLST Al 1/19/77 16:1~2 H.I.T. LINCOLN LAB3ORATORY 1 DB116 DB16 D11G12 1 DI)V8 DD V,"R DWl 1 DBV16 DBV...5 CD27 CA27 CDC.6 CAC6 "F23 CD25 CA25 CD%.4 CAt4 IN ,7 F2’ C!ൠ CA24 CDV3 CA.^ ELI 11 CI)22 CA23 CP,2 CA,2 1D1.. CA22 CDI CA. 1 "FH CD39 CA38 CD17...FC17 FE22 ,26 FC19 UE24 1 ’P27 FC19 F21 1 IP 29 FA V7 EF21 1 !p33* FA10 FF12" I %P32 FG EE1 1 IP3 FG ’i^7 EF15 1 ’P 34 FGF12 Ffl2 1 1115FG ’ 1 F12
Bowd, Christopher; Weinreb, Robert N; Balasubramanian, Madhusudhanan; Lee, Intae; Jang, Giljin; Yousefi, Siamak; Zangwill, Linda M; Medeiros, Felipe A; Girkin, Christopher A; Liebmann, Jeffrey M; Goldbaum, Michael H
2014-01-01
The variational Bayesian independent component analysis-mixture model (VIM), an unsupervised machine-learning classifier, was used to automatically separate Matrix Frequency Doubling Technology (FDT) perimetry data into clusters of healthy and glaucomatous eyes, and to identify axes representing statistically independent patterns of defect in the glaucoma clusters. FDT measurements were obtained from 1,190 eyes with normal FDT results and 786 eyes with abnormal FDT results from the UCSD-based Diagnostic Innovations in Glaucoma Study (DIGS) and African Descent and Glaucoma Evaluation Study (ADAGES). For all eyes, VIM input was 52 threshold test points from the 24-2 test pattern, plus age. FDT mean deviation was -1.00 dB (S.D. = 2.80 dB) and -5.57 dB (S.D. = 5.09 dB) in FDT-normal eyes and FDT-abnormal eyes, respectively (p<0.001). VIM identified meaningful clusters of FDT data and positioned a set of statistically independent axes through the mean of each cluster. The optimal VIM model separated the FDT fields into 3 clusters. Cluster N contained primarily normal fields (1109/1190, specificity 93.1%) and clusters G1 and G2 combined, contained primarily abnormal fields (651/786, sensitivity 82.8%). For clusters G1 and G2 the optimal number of axes were 2 and 5, respectively. Patterns automatically generated along axes within the glaucoma clusters were similar to those known to be indicative of glaucoma. Fields located farther from the normal mean on each glaucoma axis showed increasing field defect severity. VIM successfully separated FDT fields from healthy and glaucoma eyes without a priori information about class membership, and identified familiar glaucomatous patterns of loss.
Wang, Yuhao; Li, Xin; Xu, Kai; Ren, Fengbo; Yu, Hao
2017-04-01
Compressive sensing is widely used in biomedical applications, and the sampling matrix plays a critical role on both quality and power consumption of signal acquisition. It projects a high-dimensional vector of data into a low-dimensional subspace by matrix-vector multiplication. An optimal sampling matrix can ensure accurate data reconstruction and/or high compression ratio. Most existing optimization methods can only produce real-valued embedding matrices that result in large energy consumption during data acquisition. In this paper, we propose an efficient method that finds an optimal Boolean sampling matrix in order to reduce the energy consumption. Compared to random Boolean embedding, our data-driven Boolean sampling matrix can improve the image recovery quality by 9 dB. Moreover, in terms of sampling hardware complexity, it reduces the energy consumption by 4.6× and the silicon area by 1.9× over the data-driven real-valued embedding.
Tanaka, Tagayasu; Inaba, Ryoichi; Aoyama, Atsuhito
2016-01-01
Objectives: This study investigated the actual situation of noise and low-frequency sounds in firework events and their impact on pyrotechnicians. Methods: Data on firework noise and low-frequency sounds were obtained at a point located approximately 100 m away from the launch site of a firework display held in "A" City in 2013. We obtained the data by continuously measuring and analyzing the equivalent continuous sound level (Leq) and the one-third octave band of the noise and low-frequency sounds emanating from the major firework detonations, and predicted sound levels at the original launch site. Results: Sound levels of 100-115 dB and low-frequency sounds of 100-125 dB were observed at night. The maximum and mean Leq values were 97 and 95 dB, respectively. The launching noise level predicted from the sounds (85 dB) at the noise measurement point was 133 dB. Occupational exposure to noise for pyrotechnicians at the remote operation point (located 20-30 m away from the launch site) was estimated to be below 100 dB. Conclusions: Pyrotechnicians are exposed to very loud noise (>100 dB) at the launch point. We believe that it is necessary to implement measures such as fixing earplugs or earmuffs, posting a warning at the workplace, and executing a remote launching operation to prevent hearing loss caused by occupational exposure of pyrotechnicians to noise. It is predicted that both sound levels and low-frequency sounds would be reduced by approximately 35 dB at the remote operation site. PMID:27725489
Tanaka, Tagayasu; Inaba, Ryoichi; Aoyama, Atsuhito
2016-11-29
This study investigated the actual situation of noise and low-frequency sounds in firework events and their impact on pyrotechnicians. Data on firework noise and low-frequency sounds were obtained at a point located approximately 100 m away from the launch site of a firework display held in "A" City in 2013. We obtained the data by continuously measuring and analyzing the equivalent continuous sound level (Leq) and the one-third octave band of the noise and low-frequency sounds emanating from the major firework detonations, and predicted sound levels at the original launch site. Sound levels of 100-115 dB and low-frequency sounds of 100-125 dB were observed at night. The maximum and mean Leq values were 97 and 95 dB, respectively. The launching noise level predicted from the sounds (85 dB) at the noise measurement point was 133 dB. Occupational exposure to noise for pyrotechnicians at the remote operation point (located 20-30 m away from the launch site) was estimated to be below 100 dB. Pyrotechnicians are exposed to very loud noise (>100 dB) at the launch point. We believe that it is necessary to implement measures such as fixing earplugs or earmuffs, posting a warning at the workplace, and executing a remote launching operation to prevent hearing loss caused by occupational exposure of pyrotechnicians to noise. It is predicted that both sound levels and low-frequency sounds would be reduced by approximately 35 dB at the remote operation site.
Decreased retinal sensitivity after internal limiting membrane peeling for macular hole surgery.
Tadayoni, Ramin; Svorenova, Ivana; Erginay, Ali; Gaudric, Alain; Massin, Pascale
2012-12-01
To compare the retinal sensitivity and frequency of microscotomas found by spectral domain optical coherence tomography (SD-OCT) combined with scanning laser ophthalmoscopy (SLO) microperimetry after idiopathic macular hole closure, in eyes that underwent internal limiting membrane (ILM) peeling and eyes that did not. This was a retrospective, non-randomised, comparative study. Combined SD-OCT and SLO microperimetry was performed in 16 consecutive eyes after closure of an idiopathic macular hole. A customised microperimetry pattern with 29 measurement points was used. The ILM was peeled in 8/16 eyes. The main outcome measure was mean retinal sensitivity. Mean retinal sensitivity (in dB) was lower after peeling: 9.80 ± 2.35 dB with peeling versus 13.19 ± 2.92 without (p=0.0209). Postoperative microscotomas were significantly more frequent after ILM peeling: 11.3 ± 6.6 points with retinal sensitivity below 10 dB in eyes that underwent peeling versus 2.9 ± 4.6 in those that did not (p=0.0093). These results suggest that ILM peeling may reduce retinal sensitivity, and significantly increase the incidence of microscotomas. Until a prospective trial confirming or not these results, it seems justified to avoid peeling the ILM when its potential benefit seems minor or unproved, and when peeling is carried out, to limit the surface peeled to the bare minimum.
p40 (ΔNp63) expression in breast disease and its correlation with p63 immunohistochemistry
Kim, Sang Kyum; Jung, Woo Hee; Koo, Ja Seung
2014-01-01
p63 protein is widely used to identify myoepithelial cells in breast disease. There have been no comparative studies of the p63 antibodies which detect different isoforms. In this study, we examine the expression profiles of p63 protein in benign proliferative diseases and malignant tumors of the breast using pan-p63 and p40 antibodies, and analyze their diagnostic utility and clinical implications. We selected 32 adenoses, 34 intraductal papillomas, 31 ductal carcinoma in situ (DCIS), 257 invasive ductal carcinoma (IDC), and 36 metaplastic carcinomas, and created tissue microarray blocks from them. Immunohistochemical assays for p63 protein were performed on these samples. We investigated the expression patterns of the pan-p63 (TP63, 4A4, Dako, 1:700), p40 antibody [5-17, CalBiochem/EMD Biosciences, 1:2000, p40 (CB)], and p40 antibody [polyclonal, Diagnostic BioSystems, 1:100, p40 (DB)] in various forms of breast disease. We determined that p63 and p40 (DB) expression in myoepithelial cells was broadly similar and showed cognate clinicopathologic features, unlike p40 (CB). p40 (CB) was more sensitive (99.0%) but less specific (85.8%), and p63 was less sensitive (93.8%) in adenosis, IP, and DCIS. In IDCs, p63 and p40 (DB) had similar expression in cancer cells; p40 (CB) expression, however, was statistically different. In metaplastic carcinomas, both p63 and p40 (DB) had distinct expression profiles, according to their histologic subtypes. We conclude that p40 antibodies as well as pan-p63 antibody are specific and sensitive myoepithelial cell markers. Interpretation of p40 positivity in cancer cells, however, should be considered carefully, due to their relatively lower specificity. PMID:24696720
Shen, Min; Sun, Dongdong; Li, Weijie; Liu, Bing; Wang, Shenxu; Zhang, Zheng; Cao, Feng
2012-01-01
Aim. To investigate the combination effects and mechanisms of valsartan (angiotensin II type 1 receptor blocker) and LAF237 (DPP-IV inhibitor) on prevention against oxidative stress and inflammation injury in db/db mice aorta. Methods. Db/db mice (n = 40) were randomized to receive valsartan, LAF237, valsartan plus LAF237, or saline. Oxidative stress and inflammatory reaction in diabetic mice aorta were examined. Results. Valsartan or LAF237 pretreatment significantly increased plasma GLP-1 expression, reduced apoptosis of endothelial cells isolated from diabetic mice aorta. The expression of NAD(P)H oxidase subunits also significantly decreased resulting in decreased superoxide production and ICAM-1 (fold change: valsartan : 7.5 ± 0.7, P < 0.05; LAF237: 10.2 ± 1.7, P < 0.05), VCAM-1 (fold change: valsartan : 5.2 ± 1.2, P < 0.05; LAF237: 4.8 ± 0.6, P < 0.05), and MCP-1 (fold change: valsartan: 3.2 ± 0.6, LAF237: 4.7 ± 0.8; P < 0.05) expression. Moreover, the combination treatment with valsartan and LAF237 resulted in a more significant increase of GLP-1 expression. The decrease of the vascular oxidative stress and inflammation reaction was also higher than monotherapy with valsartan or LAF237. Conclusion. These data indicated that combination treatment with LAF237 and valsartan acts in a synergistic manner on vascular oxidative stress and inflammation in type 2 diabetic mice. PMID:22474415
Optimizing otoacoustic emission protocols for a UNHS program.
Hatzopoulos, S; Petruccelli, J; Ciorba, A; Martini, A
2009-01-01
To identify the optimal test protocol to screen for hearing problems in newborns, an evaluation of three distortion product otoacoustic emission (DPOAE) protocols was conducted in neonates, from a well-baby nursery (WBN) and from a neonatal intensive care unit (NICU) and compared to the performance in newborns of a more standard protocol based on transient-evoked OAEs (TEOAEs). The DPOAE protocols used asymmetrical stimulus intensities (L(1) > L(2)) with a frequency ratio of 1.22, in the following format: (P1), L(1) = 60, L(2) = 50 dB SPL; (P2), L(1) = 65, L(2) = 55 dB SPL, and (P3), L(1) = 75, L(2) = 65 dB SPL. Linear TEOAE responses, evoked by click stimuli of 75 dB peSPL, were used as controls of normal cochlear function. Five frequencies at 1.5, 2.0, 3.0, 4.0 and 5.0 kHz were tested with a common commercially available macro-based software subroutine (Otodynamics Corp, ILO-92). The project evaluated the responses from 1200 WBN infants (average age 48 h) and 350 low-birth-weight NICU infants, all randomly selected. Statistical analyses comparing the signal-to-noise ratios (S/N), at the predefined f(2) frequencies, indicated that the P1 and P2 DPOAE protocols generated similar responses. Significant S/N differences were observed in the P3 to P2 dataset comparisons. DPOAE scoring criteria were estimated from the P3 dataset using a one-sided, distribution-free confidence intervals. The scoring criteria for a 'pass' were estimated as a minimum S/N of 6.0, 7.0 and 6.0 dB at 2.0, 3.0 and 4.0 kHz, respectively. In terms of feasibility, the P3 protocol generated responses in 98% of the WBN and 94.8% of the NICU infants. All three DPOAE protocols demonstrated shorter time-recording requirements than the standard TEOAE test. The false-positive and false-negative rates for the NICU infants were estimated as 0.0028 and 0.003%, respectively.
Gibert, Olivier; Dufour, Dominique; Giraldo, Andrés; Sánchez, Teresa; Reynes, Max; Pain, Jean-Pierre; González, Alonso; Fernández, Alejandro; Díaz, Alberto
2009-09-09
The morphological, physical, and chemical characteristics of 23 unripe cultivated varieties of Colombian Musaceae were assessed. Fresh pulp dry matter helped to discriminate the following consumption subgroups: FHIA dessert hybrids (hydes: 24.6%) < dessert bananas (des: 29.4%) < nonplantain cooking bananas (cook: 32.0%) < FHIA cooking hybrids (hycook: 34.2%) < plantains (pl: 41.1%). Banana flour starch content on dry basis (db) varied from 74.2 to 88.2% among the varieties, with: pl: 86.5% > cook and hycook: 84% > des: 81.9% > hydes: 79.7% (p
Matching Automatic Gain Control Across Devices in Bimodal Cochlear Implant Users.
Veugen, Lidwien C E; Chalupper, Josef; Snik, Ad F M; Opstal, A John van; Mens, Lucas H M
2016-01-01
The purpose of this study was to improve bimodal benefit in listeners using a cochlear implant (CI) and a hearing aid (HA) in contralateral ears, by matching the time constants and the number of compression channels of the automatic gain control (AGC) of the HA to the CI. Equivalent AGC was hypothesized to support a balanced loudness for dynamically changing signals like speech and improve bimodal benefit for speech understanding in quiet and with noise presented from the side(s) at 90 degree. Fifteen subjects participated in the study, all using the same Advanced Bionics Harmony CI processor and HA (Phonak Naida S IX UP). In a 3-visit crossover design with 4 weeks between sessions, performance was measured using a HA with a standard AGC (syllabic multichannel compression with 1 ms attack time and 50 ms release time) or an AGC that was adjusted to match that of the CI processor (dual AGC broadband compression, 3 and 240 msec attack time, 80 and 1500 msec release time). In all devices, the AGC was activated above the threshold of 63 dB SPL. The authors balanced loudness across the devices for soft and loud input sounds in 3 frequency bands (0 to 548, 548 to 1000, and >1000 Hz). Speech understanding was tested in free field in quiet and in noise for three spatial speaker configurations, with target speech always presented from the front. Single-talker noise was either presented from the CI side or the HA side, or uncorrelated stationary speech-weighted noise or single-talker noise was presented from both sides. Questionnaires were administered to assess differences in perception between the two bimodal fittings. Significant bimodal benefit over the CI alone was only found for the AGC-matched HA for the speech tests with single-talker noise. Compared with the standard HA, matched AGC characteristics significantly improved speech understanding in single-talker noise by 1.9 dB when noise was presented from the HA side. AGC matching increased bimodal benefit insignificantly by 0.6 dB when noise was presented from the CI implanted side, or by 0.8 (single-talker noise) and 1.1 dB (stationary noise) in the more complex configurations with two simultaneous maskers from both sides. In questionnaires, subjects rated the AGC-matched HA higher than the standard HA for understanding of one person in quiet and in noise, and for the quality of sounds. Listening to a slightly raised voice, subjects indicated increased listening comfort with matched AGCs. At the end of the study, 9 of 15 subjects preferred to take home the AGC-matched HA, 1 preferred the standard HA and 5 subjects had no preference. For bimodal listening, the AGC-matched HA outperformed the standard HA in speech understanding in noise tasks using a single competing talker and it was favored in questionnaires and in a subjective preference test. When noise was presented from the HA side, AGC matching resulted in a 1.9 dB SNR additional benefit, even though the HA was at the least favorable SNR side in this speaker configuration. Our results possibly suggest better binaural processing for matched AGCs.
Jung, Tae Woo; Choi, Hae Yoon; Lee, So Young; Hong, Ho Cheol; Yang, Sae Jeong; Yoo, Hye Jin; Youn, Byung-Soo; Baik, Sei Hyun; Choi, Kyung Mook
2013-01-01
Selenoprotein P (SeP) was recently identified as a hepatokine that induces insulin resistance (IR) in rodents and humans. Recent clinical trials have shown that salsalate, a prodrug of salicylate, significantly lowers blood glucose levels and increases adiponectin concentrations. We examined the effects of salsalate and full length-adiponectin (fAd) on the expression of SeP under hyperlipidemic conditions and explored their regulatory mechanism on SeP. In palmitate-treated HepG2 cells as well as high fat diet (HFD)-fed male Spraque Dawley (SD) rats and male db/db mice, SeP expression and its regulatory pathway, including AMPK-FOXO1α, were evaluated after administration of salsalate and salicylate. Palmitate treatment significantly increased SeP expression and aggravated IR, while knock-down of SeP by siRNA restored these changes in HepG2 cells. Palmitate-induced SeP expression was inhibited by both salsalate and salicylate, which was mediated by AMPK activation, and was blocked by AMPK siRNA or an inhibitor of AMPK. Chromatin immunoprecipitation (ChIP) and electrophoretic mobility shift (EMSA) assay showed that salsalate suppressed SeP expression by AMPK-mediated phosphorylation of FOXO1α. Moreover, fAd also reduced palmitate-induced SeP expression through the activation of AMPK, which results in improved IR. Both salsalate and salicylate treatment significantly improved glucose intolerance and insulin sensitivity, accompanied by reduced SeP mRNA and protein expression in HFD-fed rats and db/db mice, respectively. Taken together, we found that salsalate and adiponectin ameliorated palmitate-induced IR in hepatocytes via SeP inhibition through the AMPK-FOXO1α pathway. The regulation of SeP might be a novel mechanism mediating the anti-diabetic effects of salsalate and adiponectin.
Comparison. US P-61 and Delft sediment samplers
Beverage, Joseph P.; Williams, David T.
1990-01-01
The Delft Bottle (DB) is a flow-through device designed by the Delft Hydraulic Laboratory (DHL), The Netherlands, to sample sand-sized sediment suspended in streams. The US P-61 sampler was designed by the Federal Interagency Sedimentation Project (FISP) at the St. Anthony Falls Hydraulic Laboratory, Minneapolis, Minnesota, to collect suspended sediment from deep, swift rivers. The results of two point-sampling tests in the United States, the Mississippi River near Vicksburg, Mississippi, in 1983 and the Colorado River near Blythe, California, in 1984, are provided in this report. These studies compare sand-transport rates, rather than total sediment-transport rates, because fine material washes through the DB sampler. In the United States, the commonly used limits for sand-sized material are 0.062 mm to 2.00 mm (Vanoni 1975).
Yang, Jae-Hyuk; Chang, Minho; Kwak, Dai-Soon; Wang, Joon Ho
2014-09-01
Regarding reconstruction surgery of the anterior cruciate ligament (ACL), there is still a debate whether to perform a single bundle (SB) or double bundle (DB) reconstruction. The purpose of this study was to analyze and compare the volume and surface area of femoral and tibial tunnels during transtibial SB versus transportal DB ACL reconstruction. A consecutive series of 26 patients who underwent trantibial SB ACL reconstruction and 27 patients with transportal DB ACL reconstruction using hamstring autograft from January 2010 to October 2010 were included in this study. Three-dimensional computed tomography (3D-CT) was taken within one week after operation. The CT bone images were segmented with use of Mimics software v14.0. The obtained digital images were then imported in the commercial package Geomagic Studio v10.0 and SketchUp Pro v8.0 for processing. The femoral and tibial tunnel lengths, diameters, volumes and surface areas were evaluated. A comparison between the two groups was performed using the independent-samples t-test. A p-value less than the significance value of 5% (p < 0.05) was considered statistically significant. Regarding femur tunnels, a significant difference was not found between the tunnel volume for SB technique (1,496.51 ± 396.72 mm(3)) and the total tunnel volume for DB technique (1,593.81 ± 469.42 mm(3); p = 0.366). However, the total surface area for femoral tunnels was larger in DB technique (919.65 ± 201.79 mm(2)) compared to SB technique (810.02 ± 117.98 mm(2); p = 0.004). For tibia tunnels, there was a significant difference between tunnel volume for the SB technique (2,070.43 ± 565.07 mm(3)) and the total tunnel volume for the DB technique (2,681.93 ± 668.09 mm(3); p ≤ 0.001). The tibial tunnel surface area for the SB technique (958.84 ± 147.50 mm(2)) was smaller than the total tunnel surface area for the DB technique (1,493.31 ± 220.79 mm(2); p ≤ 0.001). Although the total femoral tunnel volume was similar between two techniques, the total surface area was larger in the DB technique. For the tibia, both total tunnel volume and the surface area were larger in DB technique.
[The effects of infrasound on the blood coagulation function of guinea pigs].
Ma, Wen-min; Qi, Peng; Zhang, Jian-zhong; Yi, Yong; Chen, Xing-ming; Zhang, Jun; Han, Rui-gang
2011-03-01
To study the change of the blood coagulation function of guinea pigs exposed to 16 Hz/120 dB, 16 Hz/125 dB infrasound and to explore the mechanism of circulation system damage. Seventy-two guinea pigs were divided into 3 groups: the control group, the group exposed to 16 Hz/120 dB infrasound for 1.5 h a day and the group exposed to 16 Hz/125 dB infrasound for 1.5 h a day. Each exposure group was divided into 4 sub-groups (8 guinea pigs a sub-group) which were exposed to infrasound for 1, 7, 14 and 21 d, respectively. The coagulation function and serum nitric oxide (NO) were measured for control group and all sub-groups after exposure to infrasound. The prothrombin time (PT), international normalized ratio (INR) and serum NO of group exposed to 16 Hz/125 dB infrasound were (31.16 ± 3.05) s, 2.53 ± 1.21 and (88.304 ± 52.601) µmol/L, respectively, which were significantly higher than those [(21.36 ± 0.10) s, 1.65 ± 0.07 and (30.943 ± 26.864) µmol/L] of control group (P < 0.05). PT and INR of sub-groups exposed to 16 Hz/125 dB infrasound for 14 and 21 d were significantly higher than those of control group. NO of sub-groups exposed to 16 Hz/125 dB infrasound for 1 week and 2 weeks were significantly higher than that of control group (P < 0.05), but NO of sub-group exposed to 16 Hz/125 dB infrasound for 3 weeks decreased slightly. The blood coagulation function of guinea pigs exposed to 16 Hz/125 dB infrasound decreased, PT and INR may be used as the indexes to assess of blood coagulation function change induced by the infrasound exposure.
JPEG 2000-based compression of fringe patterns for digital holographic microscopy
NASA Astrophysics Data System (ADS)
Blinder, David; Bruylants, Tim; Ottevaere, Heidi; Munteanu, Adrian; Schelkens, Peter
2014-12-01
With the advent of modern computing and imaging technologies, digital holography is becoming widespread in various scientific disciplines such as microscopy, interferometry, surface shape measurements, vibration analysis, data encoding, and certification. Therefore, designing an efficient data representation technology is of particular importance. Off-axis holograms have very different signal properties with respect to regular imagery, because they represent a recorded interference pattern with its energy biased toward the high-frequency bands. This causes traditional images' coders, which assume an underlying 1/f2 power spectral density distribution, to perform suboptimally for this type of imagery. We propose a JPEG 2000-based codec framework that provides a generic architecture suitable for the compression of many types of off-axis holograms. This framework has a JPEG 2000 codec at its core, extended with (1) fully arbitrary wavelet decomposition styles and (2) directional wavelet transforms. Using this codec, we report significant improvements in coding performance for off-axis holography relative to the conventional JPEG 2000 standard, with Bjøntegaard delta-peak signal-to-noise ratio improvements ranging from 1.3 to 11.6 dB for lossy compression in the 0.125 to 2.00 bpp range and bit-rate reductions of up to 1.6 bpp for lossless compression.
Alcalde-Estévez, Elena; Arroba, Ana I; Sánchez-Fernández, Elena M; Mellet, Carmen Ortiz; García Fernández, Jose M; Masgrau, Laura; Valverde, Ángela M
2018-01-01
Neuroinflammation is an early event during diabetic retinopathy (DR) that impacts the dynamics of microglia polarization. Gliosis is a hallmark of DR and we have reported the beneficial effects of 1R-DSO-ONJ, a member of the sp 2 -iminosugar glycolipid (sp 2 -IGL) family, in targeting microglia and reducing gliosis in diabetic db/db mice. Herein, we analyzed the effect of DSO 2 -ONJ, another family compound incorporating a sulfone group that better mimics the phosphate group of phosphatidylinositol ether lipid analogues (PIAs), in Bv.2 microglial cells treated with bacterial lipopolysaccaride (LPS) and in retinal explants from db/db mice. In addition to decreasing iNOS and inflammasome activation, the anti-inflammatory effect of DSO 2 -ONJ was mediated by direct p38α MAPK activation. Computational docking experiments demonstrated that DSO 2 -ONJ binds to p38α MAPK at the same site where PIAs and the alkyl phospholipid perifosine activators do, suggesting similar mechanism of action. Moreover, treatment of microglial cells with DSO 2 -ONJ increased both heme-oxygenase (HO)-1 and Il10 expression regardless the presence of LPS. In retinal explants from db/db mice, DSO 2 -ONJ also induced HO-1 and reduced gliosis. Since IL-10-mediated induction of HO-1 expression is mediated by p38α MAPK activation, our results suggest that this molecular mechanism is involved in the anti-inflammatory effects of DSO 2 -ONJ in microglia. Copyright © 2017 Elsevier Ltd. All rights reserved.
A real-time chirp-coded imaging system with tissue attenuation compensation.
Ramalli, A; Guidi, F; Boni, E; Tortoli, P
2015-07-01
In ultrasound imaging, pulse compression methods based on the transmission (TX) of long coded pulses and matched receive filtering can be used to improve the penetration depth while preserving the axial resolution (coded-imaging). The performance of most of these methods is affected by the frequency dependent attenuation of tissue, which causes mismatch of the receiver filter. This, together with the involved additional computational load, has probably so far limited the implementation of pulse compression methods in real-time imaging systems. In this paper, a real-time low-computational-cost coded-imaging system operating on the beamformed and demodulated data received by a linear array probe is presented. The system has been implemented by extending the firmware and the software of the ULA-OP research platform. In particular, pulse compression is performed by exploiting the computational resources of a single digital signal processor. Each image line is produced in less than 20 μs, so that, e.g., 192-line frames can be generated at up to 200 fps. Although the system may work with a large class of codes, this paper has been focused on the test of linear frequency modulated chirps. The new system has been used to experimentally investigate the effects of tissue attenuation so that the design of the receive compression filter can be accordingly guided. Tests made with different chirp signals confirm that, although the attainable compression gain in attenuating media is lower than the theoretical value expected for a given TX Time-Bandwidth product (BT), good SNR gains can be obtained. For example, by using a chirp signal having BT=19, a 13 dB compression gain has been measured. By adapting the frequency band of the receiver to the band of the received echo, the signal-to-noise ratio and the penetration depth have been further increased, as shown by real-time tests conducted on phantoms and in vivo. In particular, a 2.7 dB SNR increase has been measured through a novel attenuation compensation scheme, which only requires to shift the demodulation frequency by 1 MHz. The proposed method characterizes for its simplicity and easy implementation. Copyright © 2015 Elsevier B.V. All rights reserved.
Strube, Patrick; Pfitzner, Berit M; Streitparth, Florian; Hartwig, Tony; Putzier, Michael
2017-01-01
The aim of the present study was to histologically compare chondrotoxicity in surgically harvested intervertebral discs (IVDs) of patients following discoblock, discography, or no preoperative intervention. Thirty patients (IVD degeneration Modic ≥ 2°, Pfirrmann 3° or 4°) at L4/5 or L5/S1 who were planned for anterior lumbar interbody fusion were randomly assigned to three groups (open MRI: group DG - discography with gadobutrol; group DB - discoblock with bupivacaine at 4 weeks prior to surgery; group C - no intervention). The intervertebral discs were histologically evaluated and compared using ANOVA and Bonferroni tests for cell count, apoptosis, and proliferation. A reduced cell count (groups DG vs. DB vs. C: 14.9 ± 7.1, 9.2 ± 3.8, and 16.6 ± 5.2 cells/mm 2 , respectively; p ANOVA = 0.016), increased apoptosis (groups DG vs. DB vs. C: 34.9 ± 10.2, 47.4 ± 16.3, 32.6 ± 12.2 %, respectively; p ANOVA = 0.039) and increased cell proliferation (post hoc pDB vs. DG or C p < 0.001; for 3-7 cell monoclonal cell nests: groups DG vs. DB vs. C: 2.4 ± 1, 3.9 ± 1, 2.2 ± 1.1, respectively; p intervention x nest size = 0.006) were found in the IVDs of patients in group DB. This in vivo study suggests that chondrotoxic effects occur in IVD cells after the intradiscal injection of bupivacaine but not after gadobutrol administration. • Local bupivacaine administration to intervertebral discs leads to cell toxicity and proliferation. • Gadobutrol demonstrated no significant effect on cell count, apoptosis, or cell proliferation. • In vivo cytotoxicity was demonstrated histologically in humans for the first time. • Addition/administration of bupivacaine during discographies must be judged critically.
Assessment and analysis of noise levels in and around Ib river coalfield, Orissa, India.
Mohapatra, Haraprasad; Goswami, Shreerup
2012-05-01
Heavy earth moving machineries, different capacities of dumpers and loaders, blasting and drilling make the mining environment noisy. A study was carried out to assess the noise level in different opencast projects in and around Belpahar and Brajarajnagar areas of Ib river coalfield. Noise assessment was carried out in various residential, commercial and industrial places. The noise levels, especially L(eq) values of different wheel loaders, dumpers, shovel and crusher units were also assessed and were more than permissible limit (90dB) in some of their operating conditions. Sound ressure level measurements while drilling into coal and overburden at Lakhanpur opencast project yielded noise levels (L(eq)) of 81.33 to 96.2 dB. Thus, these L(eq) values of drilling machines in most of the operating conditions were above permissible limit. The average noise intensities (6 a.m.-10 p.m.: 51.6-60.875dB and 10 p.m.-6 a.m.: 42.6-49.8dB) and L(eq) values (6 a.m.-10 p.m.: 50.9-67.0dB and 10 p.m.-6 a.m.: 40.8-53.3dB) during both day and night time of the residential areas around the Ib river coalfield were in close proximity or beyond the permissible limit. The L(eq) values at some of the commercial and industrial places were beyond (6 a.m.-10 p.m.: 61.6-88.3 dB and 10 p.m.-6 a.m.: 55.4-64.8dB) permissible limit. However, in most of the cases, the L(max) noise values were more (6 a.m.-10 p.m.: 68.5-91.4 dB and 10 p.m.-6 a.m.: 69.3-76.4dB) than the permissible limit. Analysis of variance was also computed for heavy earth moving machineries in different operating conditions and also for different residential, commercial and industrial places to infer the level of significance. The difference of noise intensity produced by different wheel loaders at Lakhanpur and Lilari opencast projects, drilling machines at Lakhanpur opencast project, 50 tons capacity dumpers at various conditions of Ib river coalfield within the same operating condition was significant at both 5% and 1% levels of significance. Similarly, the variance of estimated noise level in residential places during day time and commercial and industrial places during day and night time was significant at both 5% and 1% levels of significance. Moreover, a preliminary survey adopting questionnaire method amongst the mine workers and local inhabitants was also carried out to evaluate their perception about the mining related noise.
Compressed Air Quality, A Case Study In Paiton Coal Fired Power Plant Unit 1 And 2
NASA Astrophysics Data System (ADS)
Indah, Nur; Kusuma, Yuriadi; Mardani
2018-03-01
The compressed air system becomes part of a very important utility system in a Plant, including the Steam Power Plant. In PLN’S coal fired power plant, Paiton units 1 and 2, there are four Centrifugal air compressor types, which produce compressed air as much as 5.652 cfm and with electric power capacity of 1200 kW. Electricity consumption to operate centrifugal compressor is 7.104.117 kWh per year. Compressed air generation is not only sufficient in quantity (flow rate) but also meets the required air quality standards. compressed air at Steam Power Plant is used for; service air, Instrument air, and for fly Ash. This study aims to measure some important parameters related to air quality, followed by potential disturbance analysis, equipment breakdown or reduction of energy consumption from existing compressed air conditions. These measurements include counting the number of dust particles, moisture content, relative humidity, and also compressed air pressure. From the measurements, the compressed air pressure generated by the compressor is about 8.4 barg and decreased to 7.7 barg at the furthest point, so the pressure drop is 0.63 barg, this number satisfies the needs in the end user. The measurement of the number of particles contained in compressed air, for particle of 0.3 micron reaches 170,752 particles, while for the particle size 0.5 micron reaches 45,245 particles. Measurements of particles conducted at several points of measurement. For some point measurements the number of dust particle exceeds the standard set by ISO 8573.1-2010 and also NACE Code, so it needs to be improved on the air treatment process. To see the amount of moisture content in compressed air, it is done by measuring pressure dew point temperature (PDP). Measurements were made at several points with results ranging from -28.4 to 30.9 °C. The recommendation of improving compressed air quality in steam power plant, Paiton unit 1 and 2 has the potential to extend the life of instrumentation equipment, improve the reliability of equipment, and reduce the amount of energy consumption up to 502,579 kWh per year.
Pang, Daorui; You, Lijun; Zhou, Lin; Li, Tong; Zheng, Bisheng; Liu, Rui Hai
2017-12-13
The objective of the present study is to investigate the hepatic steatosis relieving effect of Averrhoa carambola free phenolic extract (ACF) on leptin receptor-deficient (db/db) mice and elucidate the modulation hepatic lipogenesis mechanisms. The serum alanine aminotransferase (ALT) and aspartate aminotransferase (AST) assays, accompanying hematoxylin and eosin (H&E) staining, were applied to identify the alleviation of liver histopathological changes. Serum and hepatic lipid assays, combined with oil red O staining, were used to investigate the amelioration of lipid accumulation. Further assessments by quantitative real-time PCR and western blot assays were used to elucidate the suppression of the fatty acid and triglyceride (TG) synthesis mechanisms underlying ACF protection. These results indicated that ACF treatment significantly reduced the liver TG of db/db mice (p < 0.05). The mechanisms are partly through phosphorylation of AMPK α and down-regulation of SREBP-1c expression, and further down-regulation of FAS and SCD1 (p < 0.05). In addition, the expression levels of mircoRNA-34a and mircoRNA-33, which modulate this signaling pathway, were significantly down-regulated by ACF treatment (p < 0.05). Collectively, these results revealed that ACF exhibited a potent hepatic steatosis relieving effect partly by inhibiting the signal transduction of hepatic lipogenesis.
Xu, Zixing; Xu, Weihong; Wang, Changsheng; Luo, Hongbin; Li, Guishuang; Chen, Rongsheng
2013-11-01
To study the effectiveness of long segment fixation combined with vertebroplasty (LSF-VP) for severe osteoporotic thoracolumbar compressive fractures with kyphosis deformity. Between March 2006 and May 2012, a retrospective analysis was made on the clinical data of 48 cases of severe osteoporotic thoracolumbar compressive fractures with more than 50% collapse of the anterior vertebral body or more than 400 of sagittal angulation, which were treated by LSF-VP in 27 cases (LSF-VP group) or percutaneous kyphoplasty (PKP) in 21 cases (PKP group). All patients suffered from single thoracolumbar vertebral compressive fracture at T11 to L2. There was no significant difference in gender, age, spinal segment, and T values of bone mineral density between 2 groups (P > 0.05). The effectiveness of the treatment was appraised by visual analogue scale (VAS), Cobb angle of thoracolumbar kyphosis, height of anterior/posterior vertebral body, and compressive ratio of vertebrae before and after operations. The LSF-VP group had longer operation time, hospitalization days, and more bone cement injection volume than the PKP group, showing significant differences (P < 0.05). Intraoperative blood loss in LSF-VP group ranged from 220 to 1,050 mL (mean, 517 mL). No pulmonaryor cerebral embolism or cerebrospinal fluid leakage was found in both groups. Asymptomatic bone cement leakage was found in 3 cases of LSF-VP group and 2 cases of PKP group. The patients were followed up for 16-78 months (mean, 41.1 months) in LSF-VP group, and 12-71 months (mean, 42.1 months) in PKP group. No fixation failure such as loosened or broken pedicle screw was found in LSF-VP group during the follow-up, and no re-fracture or adjacent vertebral body fracture was found. Two cases in PKP group at 39 and 56 months after operation respectively were found to have poor maintenance of vertebral height and loss of rectification (Cobb angle was more than 40 degrees) with recurrence of pain, which were treated by second surgery of LSF-VP; another case had compressive fracture of the adjacent segment and thoracolumbar kyphosis at 16 months after operation, which was treated by second surgery of LSF-VP. There were significant differences in the other indexes between each pair of the three time points (P < 0.05), except the Cobb angle of thoracolumbar kyphosis, and the height of posterior vertebral body between discharge and last follow-up in LSF-VP group, and except the Cobb angle of thoracolumbar kyphosis and compressive ratio of bertebrae between discharge and last follow-up in PKP group (P > 0.05). After operation, the other indexes of LSF-VP group were significantly better than those of PKP group at each time point (P < 0.05), except the VAS score and the height of posterior vertebral body at discharge (P > 0.05). The effectiveness of LSF-VP is satisfactory in treating severe osteoporotic thoracolumbar compressive fractures with kyphosis deformity. LSF-VP can acquire better rectification of kyphosis and recovery of vertebral body height than PKP.
Animal model of cochlear third window in the scala vestibuli or scala tympani.
Attias, Joseph; Preis, Michal; Shemesh, Rafi; Hadar, Tuvia; Nageris, Ben I
2010-08-01
The auditory impact of a cochlear third window differs by its location in the scala vestibuli or scala tympani. Pathologic third window has been investigated primarily in the vestibular apparatus of animals and humans. Dehiscence of the superior semicircular canal is the clinical model. Fat sand rats (n = 11) have a unique inner-ear anatomy that allows easy surgical access. A window was drilled in the bony labyrinth over the scala vestibuli in 1 group (12 ears) and over the scala tympani in another (7 ears) while preserving the membranous labyrinth. Auditory brain stem responses to high- and low-frequency stimuli delivered by air and bone conduction were recorded before and after the procedure. Scala vestibuli group: preoperative air-conduction thresholds to clicks and tone-bursts averaged 8.3 and 9.6 dB, respectively, and bone-conduction thresholds, 4.6 and 3.3 dB, respectively; after fenestration, air-conduction thresholds averaged 40.4 and 41.8 dB, respectively, and bone-conduction thresholds, -1 and 5.6 dB, respectively. Scala tympani group: preoperative air-conduction thresholds to clicks and tone-bursts averaged 8.6 dB each, and bone-conduction thresholds, 7.9 dB and 7.1 dB, respectively; after fenestration, air-conduction thresholds averaged 11.4 and 9.3 dB, respectively, and bone-conduction thresholds, 9.3 and 4.2 dB, respectively. The changes in air- (p = 0.0001) and bone-conduction (p = 0.04) thresholds were statistically significant only in the scala vestibuli group. The presence of a cochlear third window over the scala vestibuli, but not over the scala tympani, causes a significant increase in air-conduction auditory thresholds. These results agree with the theoretic model and clinical findings and contribute to our understanding of vestibular dehiscence.
Simplified design of diaphragm-based fiber optic extrinsic Fabry-Perot accelerometer
NASA Astrophysics Data System (ADS)
Wang, Zhaogang; Zhang, Wentao; Han, Jing; Huang, Wenzhu; Li, Fang
2014-11-01
A fiber optic Fabry-Perot accelerometer (FOFPA) with diaphragm-mass-collimator (DMC) gathered structure is presented. This design makes the structure more compacts and the manufacturing process more controllable. The operation principle based on Fabry-Perot interference is described. Several tests using intensity demodulation scheme which can control the working point of FOFPA were carried out. Experimental results show that: axis sensitivity of the proposed FOFPA is 36.07 dB (re: 0 dB=1 V/g) with a fluctuation less than 0.9 dB in a frequency bandwidth of 10-125 Hz, the resonant frequency is about 350 Hz, measurement range is about 70 dB@100 Hz. which are much close to theoretical values
NASA Astrophysics Data System (ADS)
Zhou, Yuxin; Wang, Xin; Tang, Zijuan; Lou, Shuqin
2018-05-01
In this paper, a switchable multi-wavelength erbium-doped fiber ring laser based on a tapered in-line Mach–Zehnder interferometer is proposed. The in-line Mach–Zehnder interferometer is fabricated by splicing a large-core fiber between two segments of single mode fibers, in which the first splicing point is tapered and the second splicing point is connected directly. By carefully rotating the polarization controller, switchable single-, dual-, triple- and quad-wavelength lasing outputs can be obtained with a side mode suppression ratio higher than 50 dB. The maximal peak power difference of multi-wavelength lasing is 3.67 dB, demonstrating a good power equalization performance. Furthermore, the proposed laser is proven to be very stable at room temperature. The wavelength shifts and peak power fluctuations are less than 0.02 nm and 1.3 dB over half an hour. In addition, stable quintuple-wavelength lasing with a side mode suppression ratio higher than 50 dB can also be realized when the filter length is changed.
Jin, Chao; Li, Huan; Li, Xianjun; Wang, Miaomiao; Liu, Congcong; Guo, Jianxin; Yang, Jian
2018-02-01
Purpose To determine whether a single 51-minute exposure to acoustic noise during 3-T multisequence magnetic resonance (MR) neuroimaging could affect the hearing threshold of healthy adults with earplugs and sponge mats as hearing protection. Materials and Methods With earplugs and motion-refraining sponge mats as hearing protection, 26 healthy young adults underwent 3-T MR neuroimaging imaging that included T1-weighted three-dimensional gradient-echo sequence, T2-weighted fast spin-echo sequence, diffusion-tensor imaging, diffusion-kurtosis imaging, T2*-weighted three-dimensional multiecho gradient-echo sequence, and blood oxygen level-dependent imaging. Automated auditory brainstem response (ABR) was used to measure the hearing thresholds within 24 hours before, within 20 minutes after, and 25 days after the MR examination. One-way repeated-measure analysis of variance with Bonferroni adjustment was used to compare automated ABR results among the three tests and partial η 2 (η p 2 ) was reported as a measure of effect size. Results Automated ABR results showed significantly increased mean threshold shift of 5.0 dB ± 8.1 (standard deviation) (left ear: 4.8 dB ± 9.2 [95% confidence interval: 1.09, 8.53], η p 2 = 0.221, P = .013; right ear: 5.2 dB ± 6.9 [95% confidence interval: 2.36, 8.02], η p 2 = 0.364, P = .001) immediately after the MR examination compared with the baseline study. This shift is below the temporary threshold shift of 40-50 dB that is associated with cochlea nerve changes. Automated ABR obtained at day 25 after MR imaging showed no significant differences from baseline (left ear: -2.3 dB ± 8.6 [95% confidence interval: -5.79, 1.78], η p 2 = 0.069, P = .185; right ear: 0.4 dB ± 7.3 [95% confidence interval: -3.35, 2.58], η p 2 = 0.003, P = .791). Conclusion A 3-T MR neuroimaging examination with the acoustic noise at equivalent sound pressure level of 103.5-111.3 dBA lasting 51 minutes can cause temporary hearing threshold shift in healthy volunteers with hearing protection. © RSNA, 2017.
NASA Technical Reports Server (NTRS)
Gabriel, Philip M.; Yeh, Penshu; Tsay, Si-Chee
2013-01-01
This paper presents results and analyses of applying an international space data compression standard to weather radar measurements that can easily span 8 orders of magnitude and typically require a large storage capacity as well as significant bandwidth for transmission. By varying the degree of the data compression, we analyzed the non-linear response of models that relate measured radar reflectivity and/or Doppler spectra to the moments and properties of the particle size distribution characterizing clouds and precipitation. Preliminary results for the meteorologically important phenomena of clouds and light rain indicate that for a 0.5 dB calibration uncertainty, typical for the ground-based pulsed-Doppler 94 GHz (or 3.2 mm, W-band) weather radar used as a proxy for spaceborne radar in this study, a lossless compression ratio of only 1.2 is achievable. However, further analyses of the non-linear response of various models of rainfall rate, liquid water content and median volume diameter show that a lossy data compression ratio exceeding 15 is realizable. The exploratory analyses presented are relevant to future satellite missions, where the transmission bandwidth is premium and storage requirements of vast volumes of data, potentially problematic.
Rail-dbGaP: analyzing dbGaP-protected data in the cloud with Amazon Elastic MapReduce.
Nellore, Abhinav; Wilks, Christopher; Hansen, Kasper D; Leek, Jeffrey T; Langmead, Ben
2016-08-15
Public archives contain thousands of trillions of bases of valuable sequencing data. More than 40% of the Sequence Read Archive is human data protected by provisions such as dbGaP. To analyse dbGaP-protected data, researchers must typically work with IT administrators and signing officials to ensure all levels of security are implemented at their institution. This is a major obstacle, impeding reproducibility and reducing the utility of archived data. We present a protocol and software tool for analyzing protected data in a commercial cloud. The protocol, Rail-dbGaP, is applicable to any tool running on Amazon Web Services Elastic MapReduce. The tool, Rail-RNA v0.2, is a spliced aligner for RNA-seq data, which we demonstrate by running on 9662 samples from the dbGaP-protected GTEx consortium dataset. The Rail-dbGaP protocol makes explicit for the first time the steps an investigator must take to develop Elastic MapReduce pipelines that analyse dbGaP-protected data in a manner compliant with NIH guidelines. Rail-RNA automates implementation of the protocol, making it easy for typical biomedical investigators to study protected RNA-seq data, regardless of their local IT resources or expertise. Rail-RNA is available from http://rail.bio Technical details on the Rail-dbGaP protocol as well as an implementation walkthrough are available at https://github.com/nellore/rail-dbgap Detailed instructions on running Rail-RNA on dbGaP-protected data using Amazon Web Services are available at http://docs.rail.bio/dbgap/ : anellore@gmail.com or langmea@cs.jhu.edu Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press.
Salati, Michele; Pompili, Cecilia; Refai, Majed; Xiumè, Francesco; Sabbatini, Armando; Brunelli, Alessandro
2014-06-01
The aim of the present study was to verify whether the implementation of an electronic health record (EHR) in our thoracic surgery unit allows creation of a high-quality clinical database saving time and costs. Before August 2011, multiple individuals compiled the on-paper documents/records and a single data manager inputted selected data into the database (traditional database, tDB). Since the adoption of an EHR in August 2011, multiple individuals have been responsible for compiling the EHR, which automatically generates a real-time database (EHR-based database, eDB), without the need for a data manager. During the initial period of implementation of the EHR, periodic meetings were held with all physicians involved in the use of the EHR in order to monitor and standardize the data registration process. Data quality of the first 100 anatomical lung resections recorded in the eDB was assessed by measuring the total number of missing values (MVs: existing non-reported value) and inaccurate values (wrong data) occurring in 95 core variables. The average MV of the eDB was compared with the one occurring in the same variables of the last 100 records registered in the tDB. A learning curve was constructed by plotting the number of MVs in the electronic database and tDB with the patients arranged by the date of registration. The tDB and eDB had similar MVs (0.74 vs 1, P = 0.13). The learning curve showed an initial phase including about 35 records, where MV in the eDB was higher than that in the tDB (1.9 vs 0.74, P = 0.03), and a subsequent phase, where the MV was similar in the two databases (0.7 vs 0.74, P = 0.6). The inaccuracy rate of these two phases in the eDB was stable (0.5 vs 0.3, P = 0.3). Using EHR saved an average of 9 min per patient, totalling 15 h saved for obtaining a dataset of 100 patients with respect to the tDB. The implementation of EHR allowed streamlining the process of clinical data recording. It saved time and human resource costs, without compromising the quality of data. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
NASA Astrophysics Data System (ADS)
Stone, Michael A.; Moore, Brian C. J.
2003-08-01
Using a ``noise-vocoder'' cochlear implant simulator [Shannon et al., Science 270, 303-304 (1995)], the effect of the speed of dynamic range compression on speech intelligibility was assessed, using normal-hearing subjects. The target speech had a level 5 dB above that of the competing speech. Initially, baseline performance was measured with no compression active, using between 4 and 16 processing channels. Then, performance was measured using a fast-acting compressor and a slow-acting compressor, each operating prior to the vocoder simulation. The fast system produced significant gain variation over syllabic timescales. The slow system produced significant gain variation only over the timescale of sentences. With no compression active, about six channels were necessary to achieve 50% correct identification of words in sentences. Sixteen channels produced near-maximum performance. Slow-acting compression produced no significant degradation relative to the baseline. However, fast-acting compression consistently reduced performance relative to that for the baseline, over a wide range of performance levels. It is suggested that fast-acting compression degrades performance for two reasons: (1) because it introduces correlated fluctuations in amplitude in different frequency bands, which tends to produce perceptual fusion of the target and background sounds and (2) because it reduces amplitude modulation depth and intensity contrasts.
Practicality of magnetic compression for plasma density control
Gueroult, Renaud; Fisch, Nathaniel J.
2016-03-16
Here, plasma densification through magnetic compression has been suggested for time-resolved control of the wave properties in plasma-based accelerators [P. F. Schmit and N. J. Fisch, Phys. Rev. Lett. 109, 255003 (2012)]. Using particle in cell simulations with real mass ratio, the practicality of large magnetic compression on timescales shorter than the ion gyro-period is investigated. For compression times shorter than the transit time of a compressional Alfven wave across the plasma slab, results show the formation of two counter-propagating shock waves, leading to a highly non-uniform plasma density profile. Furthermore, the plasma slab displays large hydromagnetic like oscillations aftermore » the driving field has reached steady state. Peak compression is obtained when the two shocks collide in the mid-plane. At this instant, very large plasma heating is observed, and the plasmaβ is estimated to be about 1. Although these results point out a densification mechanism quite different and more complex than initially envisioned, these features still might be advantageous in particle accelerators.« less
Moore, Brian C J
2012-09-01
This article reviews a series of studies on the factors influencing sound quality preferences, mostly for jazz and classical music stimuli. The data were obtained using ratings of individual stimuli or using the method of paired comparisons. For normal-hearing participants, the highest ratings of sound quality were obtained when the reproduction bandwidth was wide (55 to 16000 Hz) and ripples in the frequency response were small (less than ± 5 dB). For hearing-impaired participants listening via a simulated five-channel compression hearing aid with gains set using the CAM2 fitting method, preferences for upper cutoff frequency varied across participants: Some preferred a 7.5- or 10-kHz upper cutoff frequency over a 5-kHz cutoff frequency, and some showed the opposite preference. Preferences for a higher upper cutoff frequency were associated with a shallow high-frequency slope of the audiogram. A subsequent study comparing the CAM2 and NAL-NL2 fitting methods, with gains slightly reduced for participants who were not experienced hearing aid users, showed a consistent preference for CAM2. Since the two methods differ mainly in the gain applied for frequencies above 4 kHz (CAM2 recommending higher gain than NAL-NL2), these results suggest that extending the upper cutoff frequency is beneficial. A system for reducing "overshoot" effects produced by compression gave small but significant benefits for sound quality of a percussion instrument (xylophone). For a high-input level (80 dB SPL), slow compression was preferred over fast compression.
Goel, Atul; Nag, Pankaj; Rahuja, Neha; Srivastava, Rohit; Chaurasia, Sumit; Gautam, Sudeep; Chandra, Sharat; Siddiqi, Mohammad Imran; Srivastava, Arvind K
2014-08-25
A series of functionalized biaryl-4-carbonitriles was synthesized in three steps and evaluated for PTP-1B inhibitory activity. Among the synthesized compounds, four biaryls 6a-d showed inhibition (IC50 58-75 μM) against in vitro PTP-1B assay possibly due to interaction with amino acid residues Lys120, Tyr46 through hydrogen bonding and aromatic-aromatic interactions, respectively. Two biaryl-4-carbonitriles 6b and 6c showed improved glucose tolerance, fasting as well as postprandial blood glucose, serum total triglycerides, and increased high-density lipoprotein-cholesterol in SLM, STZ, STZ-S and C57BL/KsJ-db/db animal models. The bioanalysis of 4'-bromo-2,3-dimethyl-5-(piperidin-1-yl)biphenyl-4-carbonitrile (6b) revealed that like insulin, it increased 2-deoxyglucose uptake in skeletal muscle cells (L6 and C2C12 myotubes). The compound 6b significantly up-regulated the genes related to the insulin signaling pathways like AMPK, MAPK including glucose transporter-4 (GLUT-4) gene in muscle tissue of C57BL/KsJ-db/db mice. Furthermore, it was observed that the compound 6b up-regulated PPARα, UCP2 and HNF4α, which are key regulator of glucose, lipid, and fatty acid metabolism. Western blot analysis of the compound 6b showed that it significantly increased the phosphorylation of AMPK and p38 MAPK and ameliorated glucose uptake in C57BL/KsJ-db/db mice through the AMPK-p38 MAPK pathway. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Joint Services Electronics Program
1990-10-09
correlate the onset of superconductivity with the appearance of thermal signals. D. PUBLICATIONS CITING JSEP SPONSORSHIP 1. Mitzi , D.B., L.W. Lombardo, A...6564. 2. KIm, J.H., 1. Bozovic, D.B. Mitzi , A. Kapitulnik and J.S. Harris Jr., "Optical Anisotropy of Bi 2 Sr 2CaCu 2O8 ," Phys. Rev. B 41 (1990...7251. 3. Murray, C.A., P.L. (.ammel, D.J. Bishop, D.B. Mitzi and A. Kapitulnik, "Observation of a Hexatic Vortex Glass in Flux Lattices of the High-Tc
Choi, Kyung Ha; Lee, Hyun Ah; Park, Mi Hwa; Han, Ji-Sook
2016-08-01
The effect of mulberry (Morus alba L.) fruit extract (MFE) on hyperglycemia and insulin sensitivity in an animal model of type 2 diabetes was evaluated. C57BL/Ksj-diabetic db/db mice were divided into three groups: diabetic control, rosiglitazone, and MFE groups. Blood glucose, plasma insulin, and intraperitoneal glucose were measured, and an insulin tolerance test was performed after MFE supplementation in db/db mice. In addition, the protein levels of various targets of insulin signaling were measured by western blotting. The blood levels of glucose and HbA1c were significantly lower in the MFE-supplemented group than in the diabetic control group. Moreover, glucose and insulin tolerance tests showed that MFE treatment increased insulin sensitivity. The homeostatic index of insulin resistance significantly decreased in the MFE-supplemented group relative to the diabetic control group. MFE supplementation significantly stimulated the levels of phosphorylated (p)-AMP-activated protein kinase (pAMPK) and p-Akt substrate of 160 kDa (pAS160) and enhanced the level of plasma membrane-glucose transporter 4 (GLUT4) in skeletal muscles. Further, dietary MFE significantly increased pAMPK and decreased the levels of glucose 6-phosphatase and phosphoenolpyruvate carboxykinase in the liver. MFE may improve hyperglycemia and insulin sensitivity via activation of AMPK and AS160 in skeletal muscles and inhibition of gluconeogenesis in the liver.
Biomechanical Comparison of Five Posterior Cruciate Ligament Reconstruction Techniques.
Nuelle, Clayton W; Milles, Jeffrey L; Pfeiffer, Ferris M; Stannard, James P; Smith, Patrick A; Kfuri, Mauricio; Cook, James L
2017-07-01
No surgical technique recreates native posterior cruciate ligament (PCL) biomechanics. We compared the biomechanics of five different PCL reconstruction techniques versus the native PCL. Cadaveric knees ( n = 20) were randomly assigned to one of five reconstruction techniques: Single bundle all-inside arthroscopic inlay, single bundle all-inside suspensory fixation, single bundle arthroscopic-assisted open onlay (SB-ONL), double bundle arthroscopic-assisted open inlay (DB-INL), and double bundle all-inside suspensory fixation (DB-SUSP). Each specimen was potted and connected to a servo-hydraulic load frame for testing in three conditions: PCL intact, PCL deficient, and PCL reconstructed. Testing consisted of a posterior force up to 100 N at a rate of 1 N/s at four knee flexion angles: 10, 30, 60, and 90 degrees. Three material properties were measured under each condition: load to 5 mm displacement, maximal displacement, and stiffness. Data were normalized to the native PCL, compared across techniques, compared with all PCL-intact knees and to all PCL-deficient knees using one-way analysis of variance. For load to 5 mm displacement, intact knees required significantly ( p < 0.03) more load at 30 degrees of flexion than all reconstructions except the DB-SUSP. At 60 degrees of flexion, intact required significantly ( p < 0.01) more load than all others except the SB-ONL. At 90 degrees, intact, SB-ONL, DB-INL, and DB-SUSP required significantly more load ( p < 0.05). Maximal displacement testing showed the intact to have significantly ( p < 0.02) less laxity than all others except the DB-INL and DB-SUSP at 60 degrees. At 90 degrees the intact showed significantly ( p < 0.01) less laxity than all others except the DB-SUSP. The intact was significantly stiffer than all others at 30 degrees ( p < 0.03) and 60 degrees ( p < 0.01). Finally, the intact was significantly ( p < 0.05) stiffer than all others except the DB-SUSP at 90 degrees. No technique matched the exact properties of the native PCL, but the double bundle reconstructions more closely recreated the native biomechanics immediately after implantation, with the DB-SUSP coming closest to the native ligament. This study contributes new data for consideration in PCL reconstruction technique choice. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Nielsen, Anne Møller; Henriksen, Mikael J V; Isbye, Dan Lou; Lippert, Freddy K; Rasmussen, Lars Simon
2010-09-01
Video-based self-instruction (VSI) with a 24-min DVD and a personal resuscitation manikin solves some of the barriers associated with traditional basic life support (BLS) courses. No accurate assessment of the actual improvement in skills after attending a VSI course has been determined, and in this study we assess the skill improvement in laypersons undergoing VSI. The BLS skills of 68 untrained laypersons (high school students, their teachers and persons excluded from mainstream society) were assessed using the Laerdal ResusciAnne and PC Skill Reporting System 2.0 in a 3 min test. A total score (12-48 points) was calculated and 12 different variables were recorded. The participants attended a 24-min VSI course (MiniAnne, Laerdal) and took home the DVD and manikin for optional subsequent self-training. We repeated the test 3 1/2-4 months later. There was a significant increase in the total score (p<0.0001) from 26.5 to 34 points. The participants performed significantly better in checking responsiveness, opening the airway, checking for respiration and using the correct compression/ventilation ratio (all p-values<0.001). The compression depth improved from 38 mm to 49.5 mm and the total number of compressions increased from 67 to 141. The ventilation volume and the total number of ventilations increased, and total "hands-off" time decreased from 120.5 s to 85 s. Untrained laypersons attending a 24 min DVD-based BLS course have a significantly improved BLS performance after 3 1/2-4 months compared to pre-test skill performance. Especially the total number of compressions improved and the hands-off time decreased. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
Urbanowicz, Tomasz K; Budniak, Wiktor; Buczkowski, Piotr; Perek, Bartłomiej; Walczak, Maciej; Tomczyk, Jadwiga; Katarzyński, Sławomir; Jemielity, Marek
2014-12-01
Monitoring the central nervous system during aortic dissection repair may improve the understanding of the intraoperative changes related to its bioactivity. The aim of the study was to evaluate the influence of deep hypothermia on intraoperative brain bioactivity measured by the compressed spectral array (CSA) method and to assess the influence of the operations on postoperative cognitive function. The study enrolled 40 patients (31 men and 9 women) at the mean age of 60.2 ± 8.6 years, diagnosed with acute aortic dissection. They underwent emergency operations in deep hypothermic circulatory arrest (DHCA). During the operations, brain bioactivity was monitored with the compressed spectral array method. There were no intraoperative deaths. Electrocerebral silence during DHCA was observed in 31 patients (74%). The lowest activity was observed during DHCA: it was 0.01 ± 0.05 nW in the left hemisphere and 0.01 ± 0.03 nW in the right hemisphere. The postoperative results of neurological tests deteriorated statistically significantly (26.9 ± 1.7 points vs. 22.0 ± 1.7 points; p < 0.001), especially among patients who exhibited brain activity during DHCA. The compressed spectral array method is clinically useful in monitoring brain bioactivity during emergency operations of acute aortic dissections. Electrocerebral silence occurs in 75% of patients during DHCA. The cognitive function of patients deteriorates significantly after operations with DHCA.
NASA Astrophysics Data System (ADS)
Huang, Xiangdi
2017-02-01
One of the most influential fundamental tools in harmonic analysis is the Riesz transforms. It maps Lp functions to Lp functions for any p ∈ (1 , ∞) which plays an important role in singular operators. As an application in fluid dynamics, the norm equivalence between ‖∇u‖Lp and ‖ div u ‖ Lp +‖ curl u ‖ Lp is well established for p ∈ (1 , ∞). However, since Riesz operators sent bounded functions only to BMO functions, there is no hope to bound ‖∇u‖L∞ in terms of ‖ div u ‖ L∞ +‖ curl u ‖ L∞. As pointed out by Hoff (2006) [11], this is the main obstacle to obtain uniqueness of weak solutions for isentropic compressible flows. Fortunately, based on new observations, see Lemma 2.2, we derive an exact estimate for ‖∇u‖L∞ ≤ (2 + 1 / N)‖ div u ‖ L∞ for any N-dimensional radially symmetric vector functions u. As a direct application, we give an affirmative answer to the open problem of uniqueness of some weak solutions to the compressible spherically symmetric flows in a bounded ball.
A low insertion loss GaAs pHEMT switch utilizing dual n +-doping AlAs etching stop layers design
NASA Astrophysics Data System (ADS)
Chien, Feng-Tso; Lin, Da-Wei; Yang, Chih-Wei; Fu, Jeffrey S.; Chiu, Hsien-Chin
2010-03-01
A low insertion loss single-pole-single-throw (SPST) pseudomorphic high electron mobility transistor (pHEMT) switch utilizing the n +-type doping in AlAs etching stop layer was fabricated and investigated. This novel design reduces device sheet resistance resulting in an improvement of dc and rf power performance. In addition, the gate recess selectivity for GaAs/AlAs interface was not sacrificed after highly n +-type doping in AlAs etching stop layer. The pHEMT with n +-AlAs etching stop layer, also named Modified pHEMT (M-pHEMT), demonstrated a lower sheet resistance ( Rsh) of 65.9 Ω/γ, a higher maximum drain-to-source current ( Idmax) of 317.8 mA/mm and a higher peak transconductance ( gm) of 259.3 mS/mm which are superior to standard pHEMT performance with values of 71.9 Ω/γ, 290.3 mA/mm and 252.1 mS/mm, respectively. Due to a significant sheet resistance improvement from this novel epitaxial design, an SPST pHEMT switch was realized to manifest its industrial application potential. The results achieved an on-state insertion loss of 1.42 dB, an off-state isolation of 13.02 dB at 0.9 GHz, which were superior to traditional pHEMT switch under same condition of operation with values of 1.68 dB and 11.42 dB, respectively. It is proved that dual n +-doping AlAs etching stop layers scheme is beneficial for low loss microwave switches applications.
Stress on external hexagon and Morse taper implants submitted to immediate loading
Odo, Caroline H.; Pimentel, Marcele J.; Consani, Rafael L.X.; Mesquita, Marcelo F.; Nóbilo, Mauro A.A.
2015-01-01
Background/Aims This study aimed to evaluate the stress distribution around external hexagon (EH) and Morse taper (MT) implants with different prosthetic systems of immediate loading (distal bar (DB), casting technique (CT), and laser welding (LW)) by using photoelastic method. Methods Three infrastructures were manufactured on a model simulating an edentulous lower jaw. All models were composed by five implants (4.1 mm × 13.0 mm) simulating a conventional lower protocol. The samples were divided into six groups. G1: EH implants with DB and acrylic resin; G2: EH implants with titanium infrastructure CT; G3: EH implants with titanium infrastructure attached using LW; G4: MT implants with DB and acrylic resin; G5: MT implants with titanium infrastructure CT; G6: MT implants with titanium infrastructure attached using LW. After the infrastructures construction, the photoelastic models were manufactured and a loading of 4.9 N was applied in the cantilever. Five pre-determined points were analyzed by Fringes software. Results Data showed significant differences between the connection types (p < 0.0001), and there was no significant difference among the techniques used for infrastructure. Conclusion The reduction of the stress levels was more influenced by MT connection (except for CT). Different bar types submitted to immediate loading not influenced stress concentration. PMID:26605142
High-resolution vascular tissue characterization in mice using 55 MHz ultrasound hybrid imaging
Mahmoud, Ahmed M.; Sandoval, Cesar; Teng, Bunyen; Schnermann, Jurgen B.; Martin, Karen H.; Mustafa, S. Jamal; Mukdadi, Osama M.
2012-01-01
Ultrasound and Duplex ultrasonography in particular are routinely used to diagnose cardiovascular disease (CVD), which is the leading cause of morbidity and mortality worldwide. However, these techniques may not be able to characterize vascular tissue compositional changes due to CVD. This work describes an ultrasound-based hybrid imaging technique that can be used for vascular tissue characterization and the diagnosis of atherosclerosis. Ultrasound radiofrequency (RF) data were acquired and processed in time, frequency, and wavelet domains to extract six parameters including time integrated backscatter (TIB), time variance (Tvar), time entropy (TE), frequency integrated backscatter (FIB), wavelet root mean square value (Wrms), and wavelet integrated backscatter (WIB). Each parameter was used to reconstruct an image co-registered to morphological B-scan. The combined set of hybrid images were used to characterize vascular tissue in vitro and in vivo using three mouse models including control (C57BL/6), and atherosclerotic apolipoprotein E-knockout (APOE-KO) and APOE/A1 adenosine receptor double knockout (DKO) mice. The technique was tested using high-frequency ultrasound including single-element (center frequency = 55 MHz) and commercial array (center frequency = 40 MHz) systems providing superior spatial resolutions of 24 μm and 40 μm, respectively. Atherosclerotic vascular lesions in the APOE-KO mouse exhibited the highest values (contrast) of −10.11 ± 1.92 dB, −12.13 ± 2.13 dB, −7.54 ± 1.45 dB, −5.10 ± 1.06 dB, −5.25 ± 0.94 dB, and −10.23 ± 2.12 dB in TIB, Tvar, TE, FIB, Wrms, WIB hybrid images (n = 10, p < 0.05), respectively. Control segments of normal vascular tissue showed the lowest values of −20.20 ± 2.71 dB, −22.54 ± 4.54 dB, −14.94 ± 2.05 dB, −9.64 ± 1.34 dB, −10.20 ± 1.27 dB, and −19.36 ± 3.24 dB in same hybrid images (n = 6, p < 0.05). Results from both histology and optical images showed good agreement with ultrasound findings within a maximum error of 3.6% in lesion estimation. This study demonstrated the feasibility of a high-resolution hybrid imaging technique to diagnose atherosclerosis and characterize plaque components in mouse. In the future, it can be easily implemented on commercial ultrasound systems and eventually translated into clinics as a screening tool for atherosclerosis and the assessment of vulnerable plaques. PMID:23218908
Assessment, analysis and appraisal of road traffic noise pollution in Rourkela city, India.
Goswami, Shreerup; Swain, Bijay Kumar; Panda, Santosh Kumar
2013-09-01
The problem of road traffic noise pollution has become a concern for both the public and the policy makers. Noise level was assessed in 12 different squares of Rourkela city during different specified times (7-10 a.m., 11 a.m.-2 p.m., 3-6 p.m., 7-10 p.m., 10 p.m.-12 midnight and 4-6 a.m.). Noise descriptors such as L,eq, traffic noise index, noise pollution level, noise climate, Lday, Levening, Lnight and Lden were assessed to reveal the extent of noise pollution due to heavy traffic in this city. The equivalent noise levels of all the 12 squares were found to be much beyond the permissible limit (70dB during day time and 55dB during night time). Appallingly, even the minimum L eq and NPL values were more than 82 dB and 96 dB during day time and 69 dB and 91 dB during night time respectively. Lden values of investigated squares ranged from 83.4 to 86.1 dB and were even more than the day time permissible limit of traffic noise. The prediction model was used in the present study to predict noise pollution level instead of Leq. Comparison of predicted with that of the actual measured data demonstrated that the model used for the prediction has the ability to calibrate the multicomponent traffic noise and yield reliable results close to that by direct measurement. Lastly, it is inferred that the dimension of the traffic generated noise pollution in Rourkela is critical.
An Efficient Audio Watermarking Algorithm in Frequency Domain for Copyright Protection
NASA Astrophysics Data System (ADS)
Dhar, Pranab Kumar; Khan, Mohammad Ibrahim; Kim, Cheol-Hong; Kim, Jong-Myon
Digital Watermarking plays an important role for copyright protection of multimedia data. This paper proposes a new watermarking system in frequency domain for copyright protection of digital audio. In our proposed watermarking system, the original audio is segmented into non-overlapping frames. Watermarks are then embedded into the selected prominent peaks in the magnitude spectrum of each frame. Watermarks are extracted by performing the inverse operation of watermark embedding process. Simulation results indicate that the proposed watermarking system is highly robust against various kinds of attacks such as noise addition, cropping, re-sampling, re-quantization, MP3 compression, and low-pass filtering. Our proposed watermarking system outperforms Cox's method in terms of imperceptibility, while keeping comparable robustness with the Cox's method. Our proposed system achieves SNR (signal-to-noise ratio) values ranging from 20 dB to 28 dB, in contrast to Cox's method which achieves SNR values ranging from only 14 dB to 23 dB.
Dohi, Satoshi; Ichizuka, Kiyotake; Matsuoka, Ryu; Seo, Kohei; Nagatsuka, Masaaki; Sekizawa, Akihiko
2017-09-01
The risk of maternal and fetal mortality is high if cardiopulmonary arrest occurs during pregnancy. To assess the best position for maternal cardiopulmonary resuscitation (CPR), a prospective randomized crossover study was undertaken, involving basic life support mannequin-based simulation (BLS-MS) and a swine model of pulseless electrical activity (an unstable cardiac state) incorporating a fetal mannequin (PEA-FM). The BLS-MS (performed by certified rescuers) served to evaluate the quality of chest compressions in 30° left lateral tilt (LLT) and supine positions. Based on a 5-point scale, each rescuer subjectively graded their experience. The PEA-FM model was used to compare coronary perfusion pressure readings during CPR in supine, supine with left uterine displacement, 30° LLT, and 30° right lateral tilt positions. Compression rate and correctness of hand position, compression depth, and recoil were measures of compression quality (BLS-MS). Compared with LLT position, supine position enabled correct hand position (rate: 0.99 vs 0.88; p<0.05) and compression depth (rate: 0.76 vs 0.36; p<0.001) significantly more often. Moreover, BLS-MS rescuers found chest compressions significantly easier to perform with the mannequin in supine (vs LLT) position (difficulty score: 1.75 vs 3.95; p<0.001). In the PEA-FM study arm, supine position with left uterine displacement and right lateral tilt positions had the highest and lowest recorded coronary perfusion pressure readings, respectively. Supine position with left uterine displacement is optimal for maternal CPR. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
Efficacy of compression of different capacitance beds in the amelioration of orthostatic hypotension
NASA Technical Reports Server (NTRS)
Denq, J. C.; Opfer-Gehrking, T. L.; Giuliani, M.; Felten, J.; Convertino, V. A.; Low, P. A.
1997-01-01
Orthostatic hypotension (OH) is the most disabling and serious manifestation of adrenergic failure, occurring in the autonomic neuropathies, pure autonomic failure (PAF) and multiple system atrophy (MSA). No specific treatment is currently available for most etiologies of OH. A reduction in venous capacity, secondary to some physical counter maneuvers (e.g., squatting or leg crossing), or the use of compressive garments, can ameliorate OH. However, there is little information on the differential efficacy, or the mechanisms of improvement, engendered by compression of specific capacitance beds. We therefore evaluated the efficacy of compression of specific compartments (calves, thighs, low abdomen, calves and thighs, and all compartments combined), using a modified antigravity suit, on the end-points of orthostatic blood pressure, and symptoms of orthostatic intolerance. Fourteen patients (PAF, n = 9; MSA, n = 3; diabetic autonomic neuropathy, n = 2; five males and nine females) with clinical OH were studied. The mean age was 62 years (range 31-78). The mean +/- SEM orthostatic systolic blood pressure when all compartments were compressed was 115.9 +/- 7.4 mmHg, significantly improved (p < 0.001) over the head-up tilt value without compression of 89.6 +/- 7.0 mmHg. The abdomen was the only single compartment whose compression significantly reduced OH (p < 0.005). There was a significant increase of peripheral resistance index (PRI) with compression of abdomen (p < 0.001) or all compartments (p < 0.001); end-diastolic index and cardiac index did not change. We conclude that denervation increases vascular capacity, and that venous compression improves OH by reducing this capacity and increasing PRI. Compression of all compartments is the most efficacious, followed by abdominal compression, whereas leg compression alone was less effective, presumably reflecting the large capacity of the abdomen relative to the legs.
Jiang, Tongxiao; Wang, Guizhong; Zhang, Wei; Li, Chen; Wang, Aimin; Zhang, Zhigang
2013-02-15
We report octave-spanning spectrum generated in a tapered silica photonic crystal fiber by a mode-locked Yb:fiber ring laser at a repetition rate as high as 528 MHz. The output pulses from this laser were compressed to 62 fs. By controlling the hole expansion and core diameter, a silica PCF was tapered to 20 cm with an optimal d/Λ ratio of 0.6. Pulses with the energy of 280 pJ and the peak power of 4.5 kW were injected into the tapered fiber and the pulse spectrum was expanded from 500 to 1600 nm at the level of -30 dB.
New Technologies in Amplification: Applications to the Pediatric Population.
ERIC Educational Resources Information Center
Kopun, Judy
1995-01-01
Discussion of technological advances in amplification for children with hearing impairments focuses on the advantages and limitations of fitting children with devices that have features such as dynamic-range compression, multiband signal processing, multimemory capability, digital feedback reduction, and frequency transposition. (Author/DB)
Plasma Switch for High-Power Active Pulse Compressor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirshfield, Jay L.
2013-11-04
Results are presented from experiments carried out at the Naval Research Laboratory X-band magnicon facility on a two-channel X-band active RF pulse compressor that employed plasma switches. Experimental evidence is shown to validate the basic goals of the project, which include: simultaneous firing of plasma switches in both channels of the RF circuit, operation of quasi-optical 3-dB hybrid directional coupler coherent superposition of RF compressed pulses from both channels, and operation of the X-band magnicon directly in the RF pulse compressor. For incident 1.2 ?s pulses in the range 0.63 ? 1.35 MW, compressed pulses of peak powers 5.7 ?more » 11.3 MW were obtained, corresponding to peak power gain ratios of 8.3 ? 9.3. Insufficient bakeout and conditioning of the high-power RF circuit prevented experiments from being conducted at higher RF input power levels.« less
Performance and Uniformity of Mass-Produced SIS Mixers for ALMA Band 8 Receiver Cartridges
NASA Astrophysics Data System (ADS)
Tomura, Tomonuri; Noguchi, Takashi; Sekimoto, Yutaro; Shan, Wenlei; Sato, Naohisa; Iizuka, Yoshizo; Kumagai, Kazuyoshi; Niizeki, Yasuaki; Iwakuni, Mikio; Ito, Tetsuya
2015-05-01
The Atacama large millimeter/submillimeter array (ALMA), which was jointly built in Chile by Europe, North America and East Asia, has an observational band from 30 to 950 GHz [1], [2]. We developed receiver cartridges for ALMA Band 8 (385-500 GHz) [3]-[5] which is one of ALMA 10 frequency bands. The Band 8 receiver cartridges were produced as 73 cartridges, and 292 SIS mixers were installed in their cartridges. Also, their all cartridges were required to meet following ALMA specifications: 1. The noise temperature is less than 196 K over 80% of the frequency range and less than 292 K at any frequency from 385 to 500 GHz. 2. The image rejection ratio is larger than 10 dB over 90% of the frequency range. 3. The IF output power variation is less than 7.0 dB peak-to-peak in the 4-8 GHz band. 4. The gain compression to RF load temperatures between 77 and 373 K is less than 5%. 5. The Allan variance of the IF output power is less than 4.0×10-7 in the time scale of 0.05 s≤T≤100 s and 3.0×10-6 at 300 s. To meet these specifications, the performance and uniformity of the SIS mixers are crucial. The SIS mixers with Nb/Al-AlOx/Nb superconductor-insulator-superconductor (SIS) tunnel junctions were fabricated in a clean room of National Astronomical Observatory of Japan and over 1000 mixer chips were mass-produced. After screening these mixers, 73 Band 8 receivers were assembled and tested. We report the test results of the mass-produced mixers and the receiver cartridges in detail from a statistical point of view.
Low Voltage Current-Reused Pseudo-Differential Programmable Gain Amplifier
NASA Astrophysics Data System (ADS)
Nguyen, Huy-Hieu; Lee, Jeong-Seon; Lee, Sang-Gug
This paper reports a current-reused pseudo-differential (CRPD) programmable gain amplifier (PGA) that demonstrates small size, low power, wide band, low noise, and high linearity operation with 4 control bits. Implemented in 0.18um CMOS technology, the PGA shows the gain range from -9.9 to 8.3dB with gain error of less than ±0.38dB. The IIP3, P1dB, and smallest 3-dB bandwidth are 10.5 to 27dBm, -9 to 9.5dBm, and 250MHz, respectively. The PGA occupies the chip area of 0.04mm2 and consumes only 460 µA from a 1.2V supply.
Crisp, Jonathan G; Lovato, Luis M; Jang, Timothy B
2010-12-01
Compression ultrasonography of the lower extremity is an established method of detecting proximal lower extremity deep venous thrombosis when performed by a certified operator in a vascular laboratory. Our objective is to determine the sensitivity and specificity of bedside 2-point compression ultrasonography performed in the emergency department (ED) with portable vascular ultrasonography for the detection of proximal lower extremity deep venous thrombosis. We did this by directly comparing emergency physician-performed ultrasonography to lower extremity duplex ultrasonography performed by the Department of Radiology. This was a prospective, cross-sectional study and diagnostic test assessment of a convenience sample of ED patients with a suspected lower extremity deep venous thrombosis, conducted at a single-center, urban, academic ED. All physicians had a 10-minute training session before enrolling patients. ED compression ultrasonography occurred before Department of Radiology ultrasonography and involved identification of 2 specific points: the common femoral and popliteal vessels, with subsequent compression of the common femoral and popliteal veins. The study result was considered positive for proximal lower extremity deep venous thrombosis if either vein was incompressible or a thrombus was visualized. Sensitivity and specificity were calculated with the final radiologist interpretation of the Department of Radiology ultrasonography as the criterion standard. A total of 47 physicians performed 199 2-point compression ultrasonographic examinations in the ED. Median number of examinations per physician was 2 (range 1 to 29 examinations; interquartile range 1 to 5 examinations). There were 45 proximal lower extremity deep venous thromboses observed on Department of Radiology evaluation, all correctly identified by ED 2-point compression ultrasonography. The 153 patients without proximal lower extremity deep venous thrombosis all had a negative ED compression ultrasonographic result. One patient with a negative Department of Radiology ultrasonographic result was found to have decreased compression of the popliteal vein on ED compression ultrasonography, giving a single false-positive result, yet repeated ultrasonography by the Department of Radiology 1 week later showed a popliteal deep venous thrombosis. The sensitivity and specificity of ED 2-point compression ultrasonography for deep venous thrombosis were 100% (95% confidence interval 92% to 100%) and 99% (95% confidence interval 96% to 100%), respectively. Emergency physician-performed 2-point compression ultrasonography of the lower extremity with a portable vascular ultrasonographic machine, conducted in the ED by this physician group and in this patient sample, accurately identified the presence and absence of proximal lower extremity deep venous thrombosis. Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
Effect of Human Auditory Efferent Feedback on Cochlear Gain and Compression
Drga, Vit; Plack, Christopher J.
2014-01-01
The mammalian auditory system includes a brainstem-mediated efferent pathway from the superior olivary complex by way of the medial olivocochlear system, which reduces the cochlear response to sound (Warr and Guinan, 1979; Liberman et al., 1996). The human medial olivocochlear response has an onset delay of between 25 and 40 ms and rise and decay constants in the region of 280 and 160 ms, respectively (Backus and Guinan, 2006). Physiological studies with nonhuman mammals indicate that onset and decay characteristics of efferent activation are dependent on the temporal and level characteristics of the auditory stimulus (Bacon and Smith, 1991; Guinan and Stankovic, 1996). This study uses a novel psychoacoustical masking technique using a precursor sound to obtain a measure of the efferent effect in humans. This technique avoids confounds currently associated with other psychoacoustical measures. Both temporal and level dependency of the efferent effect was measured, providing a comprehensive measure of the effect of human auditory efferents on cochlear gain and compression. Results indicate that a precursor (>20 dB SPL) induced efferent activation, resulting in a decrease in both maximum gain and maximum compression, with linearization of the compressive function for input sound levels between 50 and 70 dB SPL. Estimated gain decreased as precursor level increased, and increased as the silent interval between the precursor and combined masker-signal stimulus increased, consistent with a decay of the efferent effect. Human auditory efferent activation linearizes the cochlear response for mid-level sounds while reducing maximum gain. PMID:25392499
Brückner, Markus; Heidemann, Jan; Nowacki, Tobias M; Cordes, Friederike; Stypmann, Jörg; Lenz, Philipp; Gohar, Faekah; Lügering, Andreas; Bettenworth, Dominik
2017-01-01
AIM To study mucosal addressin cellular adhesion molecule-1 (MAdCAM-1) and vascular endothelial growth factor (VEGF)-targeted contrast enhanced ultrasound (CEUS) for the assessment of murine colitis and carcinogenesis. METHODS C57BL/6 mice were challenged with 3% dextran sodium-sulfate (DSS) for three, six or nine days to study the development of acute colitis. Ultrasound was performed with and without the addition of unspecific contrast agents. MAdCAM-1-targeted contrast agent was used to detect and quantify MAdCAM-1 expression. Inflammatory driven colorectal azoxymethane (AOM)/DSS-induced carcinogenesis was examined on day 42 and 84 using VEGF-targeted contrast agent. Highly specific tissue echogenicity was quantified using specialized software. Sonographic findings were correlated to tissue staining, western blot analysis and immunohistochemistry to quantify the degree of inflammation and stage of carcinogenesis. RESULTS Native ultrasound detected increased general bowel wall thickening that correlated with more progressed and more severe DSS-colitis (healthy mice: 0.3 mm ± 0.03 vs six days DSS: 0.5 mm ± 0.2 vs nine days DSS: 0.6 mm ± 0.2, P < 0.05). Moreover, these sonographic findings correlated well with clinical parameters such as weight loss (r2 = 0.74) and histological damage (r2 = 0.86) (P < 0.01). In acute DSS-induced murine colitis, CEUS targeted against MAdCAM-1 detected and differentiated stages of mild, moderate and severe colitis via calculation of mean pixel contrast intensity in decibel (9.6 dB ± 1.6 vs 12.9 dB ± 1.4 vs 18 dB ± 3.33, P < 0.05). Employing the AOM/DSS-induced carcinogenesis model, tumor development was monitored by CEUS targeted against VEGF and detected a significantly increased echogenicity in tumors as compared to adjacent healthy mucosa (healthy mucosa, 1.6 dB ± 1.4 vs 42 d, 18.2 dB ± 3.3 vs 84 d, 18.6 dB ± 4.9, P < 0.01). Tissue echogenicity strongly correlated with histological analysis and immunohistochemistry findings (VEGF-positive cells in 10 high power fields of healthy mucosa: 1 ± 1.2 vs 42 d after DSS start: 2.4 ± 1.6 vs 84 d after DSS start: 3.5 ± 1.3, P < 0.01). CONCLUSION Molecularly targeted CEUS is a highly specific and non-invasive imaging modality, which characterizes murine intestinal inflammation and carcinogenesis in vivo. PMID:28522908
Brückner, Markus; Heidemann, Jan; Nowacki, Tobias M; Cordes, Friederike; Stypmann, Jörg; Lenz, Philipp; Gohar, Faekah; Lügering, Andreas; Bettenworth, Dominik
2017-04-28
To study mucosal addressin cellular adhesion molecule-1 (MAdCAM-1) and vascular endothelial growth factor (VEGF)-targeted contrast enhanced ultrasound (CEUS) for the assessment of murine colitis and carcinogenesis. C57BL/6 mice were challenged with 3% dextran sodium-sulfate (DSS) for three, six or nine days to study the development of acute colitis. Ultrasound was performed with and without the addition of unspecific contrast agents. MAdCAM-1-targeted contrast agent was used to detect and quantify MAdCAM-1 expression. Inflammatory driven colorectal azoxymethane (AOM)/DSS-induced carcinogenesis was examined on day 42 and 84 using VEGF-targeted contrast agent. Highly specific tissue echogenicity was quantified using specialized software. Sonographic findings were correlated to tissue staining, western blot analysis and immunohistochemistry to quantify the degree of inflammation and stage of carcinogenesis. Native ultrasound detected increased general bowel wall thickening that correlated with more progressed and more severe DSS-colitis (healthy mice: 0.3 mm ± 0.03 vs six days DSS: 0.5 mm ± 0.2 vs nine days DSS: 0.6 mm ± 0.2, P < 0.05). Moreover, these sonographic findings correlated well with clinical parameters such as weight loss ( r 2 = 0.74) and histological damage ( r 2 = 0.86) ( P < 0.01). In acute DSS-induced murine colitis, CEUS targeted against MAdCAM-1 detected and differentiated stages of mild, moderate and severe colitis via calculation of mean pixel contrast intensity in decibel (9.6 dB ± 1.6 vs 12.9 dB ± 1.4 vs 18 dB ± 3.33, P < 0.05). Employing the AOM/DSS-induced carcinogenesis model, tumor development was monitored by CEUS targeted against VEGF and detected a significantly increased echogenicity in tumors as compared to adjacent healthy mucosa (healthy mucosa, 1.6 dB ± 1.4 vs 42 d, 18.2 dB ± 3.3 vs 84 d, 18.6 dB ± 4.9, P < 0.01). Tissue echogenicity strongly correlated with histological analysis and immunohistochemistry findings (VEGF-positive cells in 10 high power fields of healthy mucosa: 1 ± 1.2 vs 42 d after DSS start: 2.4 ± 1.6 vs 84 d after DSS start: 3.5 ± 1.3, P < 0.01). Molecularly targeted CEUS is a highly specific and non-invasive imaging modality, which characterizes murine intestinal inflammation and carcinogenesis in vivo .
Correlation estimation and performance optimization for distributed image compression
NASA Astrophysics Data System (ADS)
He, Zhihai; Cao, Lei; Cheng, Hui
2006-01-01
Correlation estimation plays a critical role in resource allocation and rate control for distributed data compression. A Wyner-Ziv encoder for distributed image compression is often considered as a lossy source encoder followed by a lossless Slepian-Wolf encoder. The source encoder consists of spatial transform, quantization, and bit plane extraction. In this work, we find that Gray code, which has been extensively used in digital modulation, is able to significantly improve the correlation between the source data and its side information. Theoretically, we analyze the behavior of Gray code within the context of distributed image compression. Using this theoretical model, we are able to efficiently allocate the bit budget and determine the code rate of the Slepian-Wolf encoder. Our experimental results demonstrate that the Gray code, coupled with accurate correlation estimation and rate control, significantly improves the picture quality, by up to 4 dB, over the existing methods for distributed image compression.
Compressed storage of arterial pressure waveforms by selection of significant points.
de Graaf, P M; van Goudoever, J; Wesseling, K H
1997-09-01
Continuous records of arterial blood pressure can be obtained non-invasively with Finapres, even for periods of 24 hours. Increasingly, storage of such records is done digitally, requiring large disc capacities. It is therefore necessary to find methods to store blood pressure waveforms in compressed form. The method of selection of significant points known from ECG data compression is adapted. Points are selected as significant wherever the first derivative of the pressure wave changes sign. As a second stage recursive partitioning is used to select additional points such that the difference between the selected points, linearly interpolated, and the original curve remains below a maximum. This method is tested on finger arterial pressure waveform epochs of 60 s duration taken from 32 patients with a wide range of blood pressures and heart rates. An average compression factor of 4.6 (SD 1.0) is obtained when accepting a maximum difference of 3 mmHg. The root mean squared error is 1 mmHg averaged over the group of patient waveforms. Clinically relevant parameters such as systolic, diastolic and mean pressure are reproduced with an offset error of less than 0.5 (0.3) mmHg and scatter less than 0.6 (0.1) mmHg. It is concluded that a substantial compression factor can be achieved with a simple and computationally fast algorithm and little deterioration in waveform quality and pressure level accuracy.
Interaural attenuation for Sennheiser HDA 200 circumaural earphones.
Brännström, K Jonas; Lantz, Johannes
2010-06-01
Interaural attenuation (IA) was evaluated for pure tones (frequency range 125 to 16000 Hz) using Sennheiser HDA 200 circumaural earphones and Telephonics TDH-39P earphones in nine unilaterally deaf subjects. Audiometry was conducted in 1-dB steps using the manual ascending technique in accordance with ISO 8253-1. For all subjects and for all tested frequencies, the lowest IA value for HDA 200 was 42 dB. The present IA values for TDH-39P earphones closely resemble previously reported data. The findings show that the HDA 200 earphones provide more IA than the TDH-39P, especially at lower frequencies (
Code of Federal Regulations, 2011 CFR
2011-01-01
... FACILITIES NON-FEDERAL NAVIGATION FACILITIES Microwave Landing System (MLS) § 171.303 Definitions. As used in... operation of the landing guidance system. Beam center means the midpoint between the -3 dB points on the... main lobe measured at the -3 dB points and defined in angular units on the boresight, in the horizontal...
Code of Federal Regulations, 2010 CFR
2010-01-01
... FACILITIES NON-FEDERAL NAVIGATION FACILITIES Microwave Landing System (MLS) § 171.303 Definitions. As used in... operation of the landing guidance system. Beam center means the midpoint between the -3 dB points on the... main lobe measured at the -3 dB points and defined in angular units on the boresight, in the horizontal...
Code of Federal Regulations, 2012 CFR
2012-01-01
... FACILITIES NON-FEDERAL NAVIGATION FACILITIES Microwave Landing System (MLS) § 171.303 Definitions. As used in... operation of the landing guidance system. Beam center means the midpoint between the -3 dB points on the... main lobe measured at the -3 dB points and defined in angular units on the boresight, in the horizontal...
Code of Federal Regulations, 2014 CFR
2014-01-01
... FACILITIES NON-FEDERAL NAVIGATION FACILITIES Microwave Landing System (MLS) § 171.303 Definitions. As used in... operation of the landing guidance system. Beam center means the midpoint between the -3 dB points on the... main lobe measured at the -3 dB points and defined in angular units on the boresight, in the horizontal...
Code of Federal Regulations, 2013 CFR
2013-01-01
... FACILITIES NON-FEDERAL NAVIGATION FACILITIES Microwave Landing System (MLS) § 171.303 Definitions. As used in... operation of the landing guidance system. Beam center means the midpoint between the -3 dB points on the... main lobe measured at the -3 dB points and defined in angular units on the boresight, in the horizontal...
Jaakkola, A; Vesti, E; Immonen, I
1998-07-01
To evaluate the correlation between the central visual field and changes in fluorescein angiography and fundus photography in patients treated with strontium plaque radiotherapy for subfoveal exudative age related macular degeneration (AMD). Octopus program 34 automated static perimetry, fluorescein angiography, and colour fundus photography were performed on 19 patients at baseline and at 12 months after strontium-90 plaque therapy. A schematic picture outlining the areas of hyperfluorescent neovascular membranes and subretinal blood was drawn of a projected 30 degrees fundus fluorescein angiogram. This drawing was superimposed on the size adjusted Octopus visual field. The changes in retinal sensitivity were calculated and related to angiographic changes. Three of the 19 patients had a reliability factor (RF) > 15% and were excluded from further analysis. In the remaining 16 patients the mean defect (MD) and loss variance (LV) values remained unchanged in patients showing regression of the choroidal neovascular membrane (CNVM) to irradiation at 12 months. MD was 7.7 (SD 1.7) at baseline and 7.6 (1.9) at 12 months (p = 0.86), and LV was 32.6 (13.9) at baseline and 32.4 (15.7) at 12 months (p = 0.94). However, in patients with progression of the CNVM at 12 months, both the MD and LV increased significantly during the 12 month follow up (MD from 7.3 (2.9) to 13.1 (3.6) (p = 0.05) and LV from 31.0 (22.9) to 71.8 (24.1) (p = 0.017)). When comparing the mean retinal sensitivity in the area of the primary CNVM (including classic, occult, and haemorrhagic components), the results were analogous: in patients with a regression of the CNVM after irradiation the mean sensitivity remained almost unchanged. It was 10.3 (6.4) dB at baseline and 9.4 (7.3) dB at 12 months (p = 0.58). In five out of 11 patients (45%) with regression of the CNVM, the mean retinal sensitivity even improved by 2.0-5.0 dB in the area of the original lesion during follow up. Instead, in patients showing progression of the CNVM at 12 months, there was a significant loss in mean retinal sensitivity--from 9.9 (4.6) dB at baseline to 1.0 (1.1) dB at 12 months (p = 0.019). The mean retinal sensitivity in the area of the irradiated but clinically normal retina during follow up was not significantly altered (21.5 dB at baseline, 19.7 dB at 12 months (p = 0.10)). Regression of subfoveal choroidal membranes in AMD after focal strontium irradiation is connected with stabilisation or even improvement of retinal sensitivity in central visual field measured by automated perimetry. Strontium plaque irradiation does not change the sensitivity in clinically normal paramacular retina during a 12 month follow up.
Jing, Da; Luo, Erping; Cai, Jing; Tong, Shichao; Zhai, Mingming; Shen, Guanghao; Wang, Xin; Luo, Zhuojing
2016-09-01
Leptin, a major hormonal product of adipocytes, is involved in regulating appetite and energy metabolism. Substantial studies have revealed the anabolic actions of leptin on skeletons and bone cells both in vivo and in vitro. Growing evidence has substantiated that leptin receptor-deficient db/db mice exhibit decreased bone mass and impaired bone microstructure despite several conflicting results previously reported. We herein systematically investigated bone microarchitecture, mechanical strength, bone turnover and its potential molecular mechanisms in db/db mice. More importantly, we also explored an effective approach for increasing bone mass in leptin receptor-deficient animals in an easy and noninvasive manner. Our results show that deterioration of trabecular and cortical bone microarchitecture and decreases of skeletal mechanical strength-including maximum load, yield load, stiffness, energy, tissue-level modulus and hardness-in db/db mice were significantly ameliorated by 12-week, whole-body vibration (WBV) with 0.5 g, 45 Hz via micro-computed tomography (μCT), three-point bending, and nanoindentation examinations. Serum biochemical analysis shows that WBV significantly decreased serum tartrate-resistant acid phosphatase 5b (TRACP5b) and CTx-1 levels and also mitigated the reduction of serum osteocalcin (OCN) in db/db mice. Bone histomorphometric analysis confirmed that decreased bone formation-lower mineral apposition rate, bone formation rate, and osteoblast numbers in cancellous bone-in db/db mice were suppressed by WBV. Real-time PCR assays show that WBV mitigated the reductions of tibial alkaline phosphatase (ALP), OCN, Runt-related transcription factor 2 (RUNX2), type I collagen (COL1), BMP2, Wnt3a, Lrp6, and β-catenin mRNA expression, and prevented the increases of tibial sclerostin (SOST), RANK, RANKL, RANL/osteoprotegerin (OPG) gene levels in db/db mice. Our results show that WBV promoted bone quantity and quality in db/db mice with obvious anabolic and anticatabolic effects. This study not only enriches our basic knowledge about bone quality and bone turnover mechanisms in leptin receptor-deficient animals, but also advances our understanding of the skeletal sensitivity of leptin-resistant db/db mice in response to external mechanical stimulation. © 2016 American Society for Bone and Mineral Research. © 2016 American Society for Bone and Mineral Research.
Kim, Bohyoung; Lee, Kyoung Ho; Kim, Kil Joong; Mantiuk, Rafal; Kim, Hye-ri; Kim, Young Hoon
2008-06-01
The objective of our study was to assess the effects of compressing source thin-section abdominal CT images on final transverse average-intensity-projection (AIP) images. At reversible, 4:1, 6:1, 8:1, 10:1, and 15:1 Joint Photographic Experts Group (JPEG) 2000 compressions, we compared the artifacts in 20 matching compressed thin sections (0.67 mm), compressed thick sections (5 mm), and AIP images (5 mm) reformatted from the compressed thin sections. The artifacts were quantitatively measured with peak signal-to-noise ratio (PSNR) and a perceptual quality metric (High Dynamic Range Visual Difference Predictor [HDR-VDP]). By comparing the compressed and original images, three radiologists independently graded the artifacts as 0 (none, indistinguishable), 1 (barely perceptible), 2 (subtle), or 3 (significant). Friedman tests and exact tests for paired proportions were used. At irreversible compressions, the artifacts tended to increase in the order of AIP, thick-section, and thin-section images in terms of PSNR (p < 0.0001), HDR-VDP (p < 0.0001), and the readers' grading (p < 0.01 at 6:1 or higher compressions). At 6:1 and 8:1, distinguishable pairs (grades 1-3) tended to increase in the order of AIP, thick-section, and thin-section images. Visually lossless threshold for the compression varied between images but decreased in the order of AIP, thick-section, and thin-section images (p < 0.0001). Compression artifacts in thin sections are significantly attenuated in AIP images. On the premise that thin sections are typically reviewed using an AIP technique, it is justifiable to compress them to a compression level currently accepted for thick sections.
Red raspberry (Rubus idaeus L.) intake decreases oxidative stress in obese diabetic (db/db) mice.
Noratto, Giuliana D; Chew, Boon P; Atienza, Liezl M
2017-07-15
Red raspberry fruit intake was investigated on obese diabetic (db/db) mice for 8weeks. Animals fed isocaloric diets (5.3% freeze-dried raspberry, or control) were assessed for obesity-diabetes-disease risk biomarkers. Results showed that raspberry intake improved antioxidant status and lessened plasma interleukin (IL)-6 (0.3-fold of control, p<0.1); most likely through enhancing glutathione peroxidase (GPx) activity in liver (4.3-fold of control), and in blood (2.1-fold of control). Other disease-risk biomarkers were similar between groups (p>0.05). Plasma levels of total cholesterol (T-CHL), low density lipoprotein-cholesterol (LDL-CHL), and resistin were higher in the raspberry group. Overall, the enhanced detoxifying cell defenses exerted by raspberry intake might be due to its polyphenolics and fibre. This study demonstrates in vivo that raspberry intake, at a dose that can be achieved by human consumption, might protect against diabetes-induced oxidative stress. Copyright © 2017 Elsevier Ltd. All rights reserved.
2014-01-01
Background Increased levels of the most electronegative type of LDL, L5, have been observed in the plasma of patients with metabolic syndrome (MetS) and ST-segment elevation myocardial infarction and can induce endothelial dysfunction. Because men have a higher predisposition to developing coronary artery disease than do premenopausal women, we hypothesized that LDL electronegativity is increased in men and promotes endothelial damage. Methods L5 levels were compared between middle-aged men and age-matched, premenopausal women with or without MetS. We further studied the effects of gender-influenced LDL electronegativity on aortic cellular senescence and DNA damage in leptin receptor–deficient (db/db) mice by using senescence-associated–β-galactosidase and γH2AX staining, respectively. We also studied the protective effects of 17β-estradiol and genistein against electronegative LDL–induced senescence in cultured bovine aortic endothelial cells (BAECs). Results L5 levels were higher in MetS patients than in healthy subjects (P < 0.001), particularly in men (P = 0.001). LDL isolated from male db/db mice was more electronegative than that from male or female wild-type mice. In addition, LDL from male db/db mice contained abundantly more apolipoprotein CIII and induced more BAEC senescence than did female db/db or wild-type LDL. In the aortas of db/db mice but not wild-type mice, we observed cellular senescence and DNA damage, and the effect was more significant in male than in female db/db mice. Pretreatment with 17β-estradiol or genistein inhibited BAEC senescence induced by male or female db/db LDL and downregulated the expression of lectin-like oxidized LDL receptor-1 and tumor necrosis factor-alpha protein. Conclusion The gender dichotomy of LDL-induced cardiovascular damage may underlie the increased propensity to coronary artery disease in men. PMID:24666525
Lerman, Oren Z; Galiano, Robert D; Armour, Mary; Levine, Jamie P; Gurtner, Geoffrey C
2003-01-01
Although it is known that systemic diseases such as diabetes result in impaired wound healing, the mechanism for this impairment is not understood. Because fibroblasts are essential for wound repair, we compared the in vitro behavior of fibroblasts cultured from diabetic, leptin receptor-deficient (db/db) mice with wild-type fibroblasts from mice of the same genetic background in processes important during tissue repair. Adult diabetic mouse fibroblast migration exhibited a 75% reduction in migration compared to normal fibroblasts (P < 0.001) and was not significantly stimulated by hypoxia (1% O(2)), whereas wild-type fibroblast migration was up-regulated nearly twofold in hypoxic conditions (P < 0.05). Diabetic fibroblasts produced twice the amount of pro-matrix metalloproteinase-9 as normal fibroblasts, as measured by both gelatin zymography and enzyme-linked immunosorbent assay (P < 0.05). Adult diabetic fibroblasts exhibited a sevenfold impairment in vascular endothelial growth factor (VEGF) production (4.5 +/- 1.3 pg/ml versus 34.8 +/- 3.3 pg/ml, P < 0.001) compared to wild-type fibroblasts. Moreover, wild-type fibroblast production of VEGF increased threefold in response to hypoxia, whereas diabetic fibroblast production of VEGF was not up-regulated in hypoxic conditions (P < 0.001). To address the question whether these differences resulted from chronic hyperglycemia or absence of the leptin receptor, fibroblasts were harvested from newborn db/db mice before the onset of diabetes (4 to 5 weeks old). These fibroblasts showed no impairments in VEGF production under basal or hypoxic conditions, confirming that the results from db/db fibroblasts in mature mice resulted from the diabetic state and were not because of alterations in the leptin-leptin receptor axis. Markers of cellular viability including proliferation and senescence were not significantly different between diabetic and wild-type fibroblasts. We conclude that, in vitro, diabetic fibroblasts show selective impairments in discrete cellular processes critical for tissue repair including cellular migration, VEGF production, and the response to hypoxia. The VEGF abnormalities developed concurrently with the onset of hyperglycemia and were not seen in normoglycemic, leptin receptor-deficient db/db mice. These observations support a role for fibroblast dysfunction in the impaired wound healing observed in human diabetics, and also suggest a mechanism for the poor clinical outcomes that occur after ischemic injury in diabetic patients.
Cellular Dysfunction in the Diabetic Fibroblast
Lerman, Oren Z.; Galiano, Robert D.; Armour, Mary; Levine, Jamie P.; Gurtner, Geoffrey C.
2003-01-01
Although it is known that systemic diseases such as diabetes result in impaired wound healing, the mechanism for this impairment is not understood. Because fibroblasts are essential for wound repair, we compared the in vitro behavior of fibroblasts cultured from diabetic, leptin receptor-deficient (db/db) mice with wild-type fibroblasts from mice of the same genetic background in processes important during tissue repair. Adult diabetic mouse fibroblast migration exhibited a 75% reduction in migration compared to normal fibroblasts (P < 0.001) and was not significantly stimulated by hypoxia (1% O2), whereas wild-type fibroblast migration was up-regulated nearly twofold in hypoxic conditions (P < 0.05). Diabetic fibroblasts produced twice the amount of pro-matrix metalloproteinase-9 as normal fibroblasts, as measured by both gelatin zymography and enzyme-linked immunosorbent assay (P < 0.05). Adult diabetic fibroblasts exhibited a sevenfold impairment in vascular endothelial growth factor (VEGF) production (4.5 ± 1.3 pg/ml versus 34.8 ± 3.3 pg/ml, P < 0.001) compared to wild-type fibroblasts. Moreover, wild-type fibroblast production of VEGF increased threefold in response to hypoxia, whereas diabetic fibroblast production of VEGF was not up-regulated in hypoxic conditions (P < 0.001). To address the question whether these differences resulted from chronic hyperglycemia or absence of the leptin receptor, fibroblasts were harvested from newborn db/db mice before the onset of diabetes (4 to 5 weeks old). These fibroblasts showed no impairments in VEGF production under basal or hypoxic conditions, confirming that the results from db/db fibroblasts in mature mice resulted from the diabetic state and were not because of alterations in the leptin-leptin receptor axis. Markers of cellular viability including proliferation and senescence were not significantly different between diabetic and wild-type fibroblasts. We conclude that, in vitro, diabetic fibroblasts show selective impairments in discrete cellular processes critical for tissue repair including cellular migration, VEGF production, and the response to hypoxia. The VEGF abnormalities developed concurrently with the onset of hyperglycemia and were not seen in normoglycemic, leptin receptor-deficient db/db mice. These observations support a role for fibroblast dysfunction in the impaired wound healing observed in human diabetics, and also suggest a mechanism for the poor clinical outcomes that occur after ischemic injury in diabetic patients. PMID:12507913
Memory-efficient decoding of LDPC codes
NASA Technical Reports Server (NTRS)
Kwok-San Lee, Jason; Thorpe, Jeremy; Hawkins, Jon
2005-01-01
We present a low-complexity quantization scheme for the implementation of regular (3,6) LDPC codes. The quantization parameters are optimized to maximize the mutual information between the source and the quantized messages. Using this non-uniform quantized belief propagation algorithm, we have simulated that an optimized 3-bit quantizer operates with 0.2dB implementation loss relative to a floating point decoder, and an optimized 4-bit quantizer operates less than 0.1dB quantization loss.
A 16.9 dBm InP DHBT W-band power amplifier with more than 20 dB gain
NASA Astrophysics Data System (ADS)
Hongfei, Yao; Yuxiong, Cao; Danyu, Wu; Xiaoxi, Ning; Yongbo, Su; Zhi, Jin
2013-07-01
A two-stage MMIC power amplifier has been realized by use of a 1-μm InP double heterojunction bipolar transistor (DHBT). The cascode structure, low-loss matching networks, and low-parasite cell units enhance the power gain. The optimum load impedance is determined from load-pull simulation. A coplanar waveguide transmission line is adopted for its ease of fabrication. The chip size is 1.5 × 1.7 mm2 with the emitter area of 16 × 1 μm × 15 μm in the output stage. Measurements show that small signal gain is more than 20 dB over 75.5-84.5 GHz and the saturated power is 16.9 dBm @ 79 GHz with gain of 15.2 dB. The high power gain makes it very suitable for medium power amplification.
Generation of squeezing in a driven many-body system
NASA Astrophysics Data System (ADS)
Hebbe Madhusudhana, Bharath; Boguslawski, Matthew; Anquez, Martin; Robbins, Bryce; Barrios, Maryrose; Hoang, Thai; Chapman, Michael
2016-05-01
In a spin-1 Bose-Einstein condensate, the non-linear spin-dependent collisional interactions can create entanglement and squeezing. Typically, the condensate is initialized at an unstable fixed point of the phase space, and subsequent free evolution under a time-independent Hamiltonian creates the squeezed state. Alternatively, it is possible to generate squeezing by driving the system localized at a stable fixed point. Here, we demonstrate that periodic modulation of the Hamiltonian can generate highly squeezed states. Our measurements show -5 dB of squeezing, limited by the detection, but calculations indicate that a theoretical potential of -20 dB of squeezing. We discuss the advantages of this method compared with the typical techniques.
Off-nadir antenna bias correction using Amazon rain forest sigma deg data. [Brazil
NASA Technical Reports Server (NTRS)
Birrer, I. J.; Bracalente, E. M.; Dome, G. J.; Sweet, J.; Berthold, G.; Moore, R. K. (Principal Investigator)
1981-01-01
The radar response from the Amazon rain forest was studied to determine the suitability of this region for use as a standard target to calibrate a scatterometer like that proposed for the National Ocean Satellite System (NOSS). Backscattering observations made by the SEASAT-1 scatterometer system show the Amazon rain forest to be a homogeneous, azimuthally-isotropic, radar target which is insensitive to polarization. The variation with angle of incidence may be adequately modeled as sigma deg (dB) = alpha theta + beta with typical values for the incidence-angle coefficient from 0.07 dB deg to 0.15 dB/deg. A small diurnal effect occurs, with measurements at sunrise being 0.5 dB to 1 dB higher than the rest of the day. Maximum likelihood estimation algorithms are presented which permit determination of relative bias and true pointing angle for each beam. Specific implementation of these algorithms for the proposed NOSS scatterometer system is also discussed.
Medellin-Kowalewski, Alexandra; Wilkens, Rune; Wilson, Alexandra; Ruan, Ji; Wilson, Stephanie R
2016-01-01
The primary objective of our study was to examine the association between contrast-enhanced ultrasound (CEUS) parameters and established gray-scale ultrasound with color Doppler imaging (CDI) for the determination of disease activity in patients with Crohn disease. Our secondary objective was to develop quantitative time-signal intensity curve thresholds for disease activity. One hundred twenty-seven patients with Crohn disease underwent ultrasound with CDI and CEUS. Reviewers graded wall thickness, inflammatory fat, and mural blood flow as showing remission or inflammation (mild, moderate, or severe). If both gray-scale ultrasound and CDI predicted equal levels of disease activity, the studies were considered concordant. If ultrasound images suggested active disease not supported by CDI findings, the ultrasound results for disease activity were indeterminate. Time-signal intensity curves from CEUS were acquired with calculation of peak enhancement (PE), and AUCs. Interobserver variation and associations between PE and ultrasound parameters were examined. Multiclass ROC analysis was used to develop CEUS thresholds for activity. Ninety-six (76%) studies were concordant, 19 of which showed severe disease, and 31 (24%) studies were indeterminate. Kappa analyses revealed good interobserver agreement on grades for CDI (κ = 0.76) and ultrasound (κ = 0.80) assessments. PE values on CEUS and wall thickness showed good association with the Spearman rank correlation coefficient for the entire population (ρ = 0.62, p < 0.01) and for the concordant group (ρ = 0.70, p < 0.01). Multiclass ROC analyses of the concordant group using wall thickness alone as the reference standard showed cutoff points of 18.2 dB for differentiating mild versus moderate activity (sensitivity, 89.0% and specificity, 87.0%) and 23.0 dB for differentiating moderate versus severe (sensitivity, 90% and specificity, 86.8%). Almost identical cutoff points were observed when using ultrasound global assessment as the reference standard: using 18.2 dB to differentiate mild versus moderate activity yielded sensitivity of 89.2% and specificity of 90.9% and using 22.9 dB to differentiate moderate versus severe activity yielded sensitivity of 89.5% and specificity of 83.1%. Quantitative CEUS parameters integrated into inflammatory assessments with ultrasound reduce indeterminate results and improve disease activity level determinations.
Wenzler, Tanja; Boykin, David W; Ismail, Mohamed A; Hall, James Edwin; Tidwell, Richard R; Brun, Reto
2009-10-01
African sleeping sickness is a fatal parasitic disease, and all drugs currently in use for treatment have strong liabilities. It is essential to find new, effective, and less toxic drugs, ideally with oral application, to control the disease. In this study, the aromatic diamidine DB75 (furamidine) and two aza analogs, DB820 and DB829 (CPD-0801), as well as their methoxyamidine prodrugs and amidoxime metabolites, were evaluated against African trypanosomes. The active parent diamidines showed similar in vitro profiles against different Trypanosoma brucei strains, melarsoprol- and pentamidine-resistant lines, and a P2 transporter knockout strain (AT1KO), with DB75 as the most trypanocidal molecule. In the T. b. rhodesiense strain STIB900 acute mouse model, the aza analogs DB820 and DB829 demonstrated activities superior to that of DB75. The aza prodrugs DB844 and DB868, as well as two metabolites of DB844, were orally more potent in the T. b. brucei strain GVR35 mouse central nervous system (CNS) model than DB289 (pafuramidine maleate). Unexpectedly, the parent diamidine DB829 showed high activity in the mouse CNS model by the intraperitoneal route. In conclusion, DB868 with oral and DB829 with parenteral application are potential candidates for further development of a second-stage African sleeping sickness drug.
[Spectral characteristics of refractive index based on nanocoated optical fiber F-P sensor].
Jiang, Ming-Shun; Li, Qiu-Shun; Sui, Qing-Mei; Jia, Lei; Peng, Peng
2013-01-01
An optical fiber Fabry-Perot (F-P) interferometer end surface was modified using layer-by-layer assembly and chemical covalent cross linking method, and the refractive index (RI) response characteristics of coated optical fiber F-P sensor were experimentally studied. Poly diallyldimethylammonium chloride (PDDA) and sodium polystyrene sulfonate (PSS) were chosen as nano-film materials. With the numbers of layers increasing, the reflection spectral contrast of optical fiber F-P sensor presents from high to low, then to high regularity. And the reflection spectral contrast has good temperature stability. The reflection spectra of the optical F-P sensor coated with 20 bilayers for a series of concentration of sucrose and inorganic solution were measured. Experimental results show that the inflection point extends from 1.457 to 1.462 3, and the reflection spectral contrast sensitivity to low RI material and high RI material is 24.53 and 3.60 dB x RI(-1), respectively, with good linearity. The results demonstrate that the functional coated optical F-P sensor provides a new method for biology and chemical material test.
Kobayashi, Miho; Nomura, Masaru; Kimoto, Hiromi
2007-11-01
This study was designed selectively to eliminate a theta-plasmid from Lactococcus lactis strains by transforming synthetic competitors. A shuttle vector for Escherichia coli and L. lactis, pDB1, was constructed by ligating a partial replicon of pDR1-1B, which is a 7.3 kb theta-plasmid in L. lactis DRC1, with an erythromycin resistance gene into pBluescript II KS(+). This versatile vector was used to construct competitors to common lactococcal theta-plasmids. pDB1 contains the 5' half of the replication origin and the 3' region of repB of pDR1-1B, but lacks the 1.1-kb region normally found between these two segments. A set of primers, Pv3 and Pv4, was designed to amplify the 1.1-kb middle parts of the general theta-replicons of lactococcal plasmids. When the PCR products were cloned into the Nru I and Xho I sites of pDB1, synthetic replicons were constructed and replication activity was restored. A number of theta-plasmids in L. lactis ssp. lactis and cremoris were eliminated selectively by transforming the synthetic competitors. These competitors were easily eliminated by subculture for a short time in the absence of selection. The resulting variants contained no exogenous DNA and are suitable for food products, since part of the phenotype was altered without altering other plasmids indispensable for fermentation.
Deflection amplifier for image dissectors
NASA Technical Reports Server (NTRS)
Salomon, P. M.
1977-01-01
Balanced symmetrical y-axis amplifier uses zener-diode level shifting to interface operational amplifiers to high voltage bipolar output stages. Nominal voltage transfer characteristic is 40 differential output volts per input volt; bandwidth, between -3-dB points, is approximately 8 kHz; loop gain is nominally 89 dB with closed loop gain of 26 dB.
Sperlich, Billy; Born, Dennis-Peter; Kaskinoro, Kimmo; Kalliokoski, Kari K; Laaksonen, Marko S
2013-01-01
The purpose of this experiment was to investigate skeletal muscle blood flow and glucose uptake in m. biceps (BF) and m. quadriceps femoris (QF) 1) during recovery from high intensity cycle exercise, and 2) while wearing a compression short applying ~37 mmHg to the thigh muscles. Blood flow and glucose uptake were measured in the compressed and non-compressed leg of 6 healthy men by using positron emission tomography. At baseline blood flow in QF (P = 0.79) and BF (P = 0.90) did not differ between the compressed and the non-compressed leg. During recovery muscle blood flow was higher compared to baseline in both compressed (P<0.01) and non-compressed QF (P<0.001) but not in compressed (P = 0.41) and non-compressed BF (P = 0.05; effect size = 2.74). During recovery blood flow was lower in compressed QF (P<0.01) but not in BF (P = 0.26) compared to the non-compressed muscles. During baseline and recovery no differences in blood flow were detected between the superficial and deep parts of QF in both, compressed (baseline P = 0.79; recovery P = 0.68) and non-compressed leg (baseline P = 0.64; recovery P = 0.06). During recovery glucose uptake was higher in QF compared to BF in both conditions (P<0.01) with no difference between the compressed and non-compressed thigh. Glucose uptake was higher in the deep compared to the superficial parts of QF (compression leg P = 0.02). These results demonstrate that wearing compression shorts with ~37 mmHg of external pressure reduces blood flow both in the deep and superficial regions of muscle tissue during recovery from high intensity exercise but does not affect glucose uptake in BF and QF.
High-resolution vascular tissue characterization in mice using 55MHz ultrasound hybrid imaging.
Mahmoud, Ahmed M; Sandoval, Cesar; Teng, Bunyen; Schnermann, Jurgen B; Martin, Karen H; Mustafa, S Jamal; Mukdadi, Osama M
2013-03-01
Ultrasound and Duplex ultrasonography in particular are routinely used to diagnose cardiovascular disease (CVD), which is the leading cause of morbidity and mortality worldwide. However, these techniques may not be able to characterize vascular tissue compositional changes due to CVD. This work describes an ultrasound-based hybrid imaging technique that can be used for vascular tissue characterization and the diagnosis of atherosclerosis. Ultrasound radiofrequency (RF) data were acquired and processed in time, frequency, and wavelet domains to extract six parameters including time integrated backscatter (T(IB)), time variance (T(var)), time entropy (T(E)), frequency integrated backscatter (F(IB)), wavelet root mean square value (W(rms)), and wavelet integrated backscatter (W(IB)). Each parameter was used to reconstruct an image co-registered to morphological B-scan. The combined set of hybrid images were used to characterize vascular tissue in vitro and in vivo using three mouse models including control (C57BL/6), and atherosclerotic apolipoprotein E-knockout (APOE-KO) and APOE/A(1) adenosine receptor double knockout (DKO) mice. The technique was tested using high-frequency ultrasound including single-element (center frequency=55 MHz) and commercial array (center frequency=40 MHz) systems providing superior spatial resolutions of 24 μm and 40 μm, respectively. Atherosclerotic vascular lesions in the APOE-KO mouse exhibited the highest values (contrast) of -10.11±1.92 dB, -12.13±2.13 dB, -7.54±1.45 dB, -5.10±1.06 dB, -5.25±0.94 dB, and -10.23±2.12 dB in T(IB), T(var), T(E), F(IB), W(rms), W(IB) hybrid images (n=10, p<0.05), respectively. Control segments of normal vascular tissue showed the lowest values of -20.20±2.71 dB, -22.54±4.54 dB, -14.94±2.05 dB, -9.64±1.34 dB, -10.20±1.27 dB, and -19.36±3.24 dB in same hybrid images (n=6, p<0.05). Results from both histology and optical images showed good agreement with ultrasound findings within a maximum error of 3.6% in lesion estimation. This study demonstrated the feasibility of a high-resolution hybrid imaging technique to diagnose atherosclerosis and characterize plaque components in mouse. In the future, it can be easily implemented on commercial ultrasound systems and eventually translated into clinics as a screening tool for atherosclerosis and the assessment of vulnerable plaques. Copyright © 2012 Elsevier B.V. All rights reserved.
Wininger, Fred A; Kapatkin, Amy S; Radin, Alex; Shofer, Frances S; Smith, Gail K
2007-12-01
To compare failure mode and bending moment of a canine pancarpal arthrodesis construct using either a 2.7 mm/3.5 mm hybrid dynamic compression plate (HDCP) or a 3.5 mm dynamic compression plate (DCP). Paired in vitro biomechanical testing of canine pancarpal arthrodesis constructs stabilized with either a 2.7/3.5 HDCP or 3.5 DCP. Paired cadaveric canine antebrachii (n=5). Pancarpal arthrodesis constructs were loaded to failure (point of maximum load) in 4-point bending using a materials-testing machine. Using this point of failure, bending moments were calculated from system variables for each construct and the 2 plating systems compared using a paired t-test. To examine the relationship between metacarpal diameter and screw diameter failure loads, linear regression was used and Pearson' correlation coefficient was calculated. Significance was set at P<.05. HDCP failed at higher loads than DCP for 9 of 10 constructs. The absolute difference in failure rates between the 2 plates was 0.552+/-0.182 N m, P=.0144 (95% confidence interval: -0.58 to 1.68). This is an 8.1% mean difference in bending strength. There was a significant linear correlation r=0.74 (P-slope=.014) and 0.8 (P-slope=.006) between metacarpal diameter and failure loads for the HDCP and 3.5 DCP, respectively. There was a small but significant difference between bending moment at failure between 2.7/3.5 HDCP and 3.5 DCP constructs; however, the difference may not be clinically evident in all patients. The 2.7/3.5 HDCP has physical and mechanical properties making it a more desirable plate for pancarpal arthrodesis.
Adrenic acid as an inflammation enhancer in non-alcoholic fatty liver disease.
Horas H Nababan, Saut; Nishiumi, Shin; Kawano, Yuki; Kobayashi, Takashi; Yoshida, Masaru; Azuma, Takeshi
2017-06-01
This study was designed to identify novel links between lipid species and disease progression in non-alcoholic fatty liver disease (NAFLD). We analyzed lipid species in the liver and plasma of db/db mice fed a choline-deficient l-amino acid-defined, high-fat diet (CDAHFD) using liquid chromatography/mass spectrometry (LC/MS). An in vitro experiment was performed using HepG2 cells stimulated with recombinant human TNFα or IL1β. The expression of steatosis-, inflammation-, and fibrosis-related genes were analyzed. Plasma samples from NAFLD patients were also analyzed by LC/MS. The CDAHFD-fed db/db mice with hepatic steatosis, inflammation, mild fibrosis, obesity, and hypercholesterolemia displayed significantly higher hepatic and plasma levels of free adrenic acid (p < 0.05). The accumulated adrenic acid in the CDAHFD-fed db/db mice was associated with increased expression of ELOVL2 and 5, and the suppression of the acyl-CoA oxidase 1 gene during peroxisomal β-oxidation. The pretreatment of HepG2 cells with adrenic acid enhanced their cytokine-induced cytokines and chemokines mRNA expression. In NAFLD patients, the group with the highest ALT levels exhibited higher plasma adrenic acid concentrations than the other ALT groups (p-value for trend <0.001). Data obtained demonstrated that adrenic acid accumulation contributes to disease progression in NAFLD. Copyright © 2017 Elsevier Inc. All rights reserved.
Huang, Shan-Shan; Ding, Da-Fa; Chen, Sheng; Dong, Cheng-Long; Ye, Xiao-Long; Yuan, Yang-Gang; Feng, Ya-Min; You, Na; Xu, Jia-Rong; Miao, Heng; You, Qiang; Lu, Xiang; Lu, Yi-Bing
2017-01-01
Podocyte apoptosis coincides with albuminuria onset and precedes podocytopenia in diabetic nephropathy. However, there is a lack of effective therapeutic drugs to protect podocytes from apoptosis. Here, we demonstrated that resveratrol relieved a series of indicators of diabetic nephropathy and attenuated apoptosis of podocytes in db/db diabetic model mice. In addition, resveratrol induced autophagy in both db/db mice and human podocytes. Furthermore, inhibition of autophagy by 3-methyladenine (3-MA) and autophagy gene 5 (Atg5) short hairpin RNA (shRNA) reversed the protective effects of resveratrol on podocytes. Finally, we found that resveratrol might regulate autophagy and apoptosis in db/db mice and podocytes through the suppression of microRNA-383-5p (miR-383-5p). Together, our results indicate that resveratrol effectively attenuates high glucose-induced apoptosis via the activation of autophagy in db/db mice and podocytes, which involves miR-383-5p. Thus, this study reveals a new possible strategy to treat diabetic nephropathy. PMID:28374806
The effect of hydraulic bed movement on the quality of chest compressions.
Park, Maeng Real; Lee, Dae Sup; In Kim, Yong; Ryu, Ji Ho; Cho, Young Mo; Kim, Hyung Bin; Yeom, Seok Ran; Min, Mun Ki
2017-08-01
The hydraulic height control systems of hospital beds provide convenience and shock absorption. However, movements in a hydraulic bed may reduce the effectiveness of chest compressions. This study investigated the effects of hydraulic bed movement on chest compressions. Twenty-eight participants were recruited for this study. All participants performed chest compressions for 2min on a manikin and three surfaces: the floor (Day 1), a firm plywood bed (Day 2), and a hydraulic bed (Day 3). We considered 28 participants of Day 1 as control and each 28 participants of Day 2 and Day 3 as study subjects. The compression rates, depths, and good compression ratios (>5-cm compressions/all compressions) were compared between the three surfaces. When we compared the three surfaces, we did not detect a significant difference in the speed of chest compressions (p=0.582). However, significantly lower values were observed on the hydraulic bed in terms of compression depth (p=0.001) and the good compression ratio (p=0.003) compared to floor compressions. When we compared the plywood and hydraulic beds, we did not detect significant differences in compression depth (p=0.351) and the good compression ratio (p=0.391). These results indicate that the movements in our hydraulic bed were associated with a non-statistically significant trend towards lower-quality chest compressions. Copyright © 2017 Elsevier Inc. All rights reserved.
Parnell, Laurence D.; Iyer, Lakshmanan K.; Liu, Zhenhua; Kane, Anne V.; Chen, C-Y. Oliver; Tai, Albert K.; Bowman, Thomas A.; Obin, Martin S.; Mason, Joel B.; Greenberg, Andrew S.; Choi, Sang-Woon; Selhub, Jacob; Paul, Ligi; Crott, Jimmy W.
2015-01-01
Obesity is a risk factor for colorectal cancer (CRC), and alterations in the colonic microbiome and metabolome may be mechanistically involved in this relationship. The relative contribution of diet and obesity per se are unclear. We compared the effect of diet- and genetically-induced obesity on the intestinal microbiome and metabolome in a mouse model of CRC. Apc1638N mice were made obese by either high fat (HF) feeding or the presence of the Leprdb/db (DbDb) mutation. Intestinal tumors were quantified and stool microbiome and metabolome were profiled. Genetic obesity, and to a lesser extent HF feeding, promoted intestinal tumorigenesis. Each induced distinct microbial patterns: taxa enriched in HF were mostly Firmicutes (6 of 8) while those enriched in DbDb were split between Firmicutes (7 of 12) and Proteobacteria (5 of 12). Parabecteroides distasonis was lower in tumor-bearing mice and its abundance was inversely associated with colonic Il1b production (p<0.05). HF and genetic obesity altered the abundance of 49 and 40 fecal metabolites respectively, with 5 in common. Of these 5, adenosine was also lower in obese and in tumor-bearing mice (p<0.05) and its concentration was inversely associated with colonic Il1b and Tnf production (p<0.05). HF and genetic obesity differentially alter the intestinal microbiome and metabolome. A depletion of adenosine and P.distasonis in tumor-bearing mice could play a mechanistic role in tumor formation. Adenosine and P. distasonis have previously been shown to be anti-inflammatory in the colon and we postulate their reduction could promote tumorigenesis by de-repressing inflammation. PMID:26284788
Pfalzer, Anna C; Nesbeth, Paula-Dene C; Parnell, Laurence D; Iyer, Lakshmanan K; Liu, Zhenhua; Kane, Anne V; Chen, C-Y Oliver; Tai, Albert K; Bowman, Thomas A; Obin, Martin S; Mason, Joel B; Greenberg, Andrew S; Choi, Sang-Woon; Selhub, Jacob; Paul, Ligi; Crott, Jimmy W
2015-01-01
Obesity is a risk factor for colorectal cancer (CRC), and alterations in the colonic microbiome and metabolome may be mechanistically involved in this relationship. The relative contribution of diet and obesity per se are unclear. We compared the effect of diet- and genetically-induced obesity on the intestinal microbiome and metabolome in a mouse model of CRC. Apc1638N mice were made obese by either high fat (HF) feeding or the presence of the Leprdb/db (DbDb) mutation. Intestinal tumors were quantified and stool microbiome and metabolome were profiled. Genetic obesity, and to a lesser extent HF feeding, promoted intestinal tumorigenesis. Each induced distinct microbial patterns: taxa enriched in HF were mostly Firmicutes (6 of 8) while those enriched in DbDb were split between Firmicutes (7 of 12) and Proteobacteria (5 of 12). Parabecteroides distasonis was lower in tumor-bearing mice and its abundance was inversely associated with colonic Il1b production (p<0.05). HF and genetic obesity altered the abundance of 49 and 40 fecal metabolites respectively, with 5 in common. Of these 5, adenosine was also lower in obese and in tumor-bearing mice (p<0.05) and its concentration was inversely associated with colonic Il1b and Tnf production (p<0.05). HF and genetic obesity differentially alter the intestinal microbiome and metabolome. A depletion of adenosine and P.distasonis in tumor-bearing mice could play a mechanistic role in tumor formation. Adenosine and P. distasonis have previously been shown to be anti-inflammatory in the colon and we postulate their reduction could promote tumorigenesis by de-repressing inflammation.
Yeung, Joyce; Davies, Robin; Gao, Fang; Perkins, Gavin D
2014-04-01
This study aims to compare the effect of three CPR prompt and feedback devices on quality of chest compressions amongst healthcare providers. A single blinded, randomised controlled trial compared a pressure sensor/metronome device (CPREzy), an accelerometer device (Phillips Q-CPR) and simple metronome on the quality of chest compressions on a manikin by trained rescuers. The primary outcome was compression depth. Secondary outcomes were compression rate, proportion of chest compressions with inadequate depth, incomplete release and user satisfaction. The pressure sensor device improved compression depth (37.24-43.64 mm, p=0.02), the accelerometer device decreased chest compression depth (37.38-33.19 mm, p=0.04) whilst the metronome had no effect (39.88 mm vs. 40.64 mm, p=0.802). Compression rate fell with all devices (pressure sensor device 114.68-98.84 min(-1), p=0.001, accelerometer 112.04-102.92 min(-1), p=0.072 and metronome 108.24 min(-1) vs. 99.36 min(-1), p=0.009). The pressure sensor feedback device reduced the proportion of compressions with inadequate depth (0.52 vs. 0.24, p=0.013) whilst the accelerometer device and metronome did not have a statistically significant effect. Incomplete release of compressions was common, but unaffected by the CPR feedback devices. Users preferred the accelerometer and metronome devices over the pressure sensor device. A post hoc study showed that de-activating the voice prompt on the accelerometer device prevented the deterioration in compression quality seen in the main study. CPR feedback devices vary in their ability to improve performance. In this study the pressure sensor device improved compression depth, whilst the accelerometer device reduced it and metronome had no effect. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Comparison of the compressive strength of 3 different implant design systems.
Pedroza, Jose E; Torrealba, Ysidora; Elias, Augusto; Psoter, Walter
2007-01-01
The aims of this study were twofold: to compare the static compressive strength at the implant-abutment interface of 3 design systems and to describe the implant abutment connection failure mode. A stainless steel holding device was designed to align the implants at 30 degrees with respect to the y-axis. Sixty-nine specimens were used, 23 for each system. A computer-controlled universal testing machine (MTS 810) applied static compression loading by a unidirectional vertical piston until failure. Specimens were evaluated macroscopically for longitudinal displacement, abutment looseness, and screw and implant fracture. Data were analyzed by analysis of variance (ANOVA). The mean compressive strength for the Unipost system was 392.5 psi (SD +/-40.9), for the Spline system 342.8 psi (SD+/-25.8), and for the Screw-Vent system 269.1 psi (SD+/-30.7). The Unipost implant-abutment connection demonstrated a statistically significant superior mechanical stability (P < or = .009) compared with the Spline implant system. The Spline implant system showed a statistically significant higher compressive strength than the Screw-Vent implant system (P < or =.009). Regarding failure mode, the Unipost system consistently broke at the same site, while the other systems failed at different points of the connection. The Unipost system demonstrated excellent fracture resistance to compressive forces; this resistance may be attributed primarily to the diameter of the abutment screw and the 2.5 mm counter bore, representing the same and a unique piece of the implant. The Unipost implant system demonstrated a statistically significant superior compressive strength value compared with the Spline and Screw-Vent systems, at a 30 degrees angulation.
Hearing and Otoacoustic Emissions Outcome of Stapedotomy: Does the Prosthesis Diameter Matter?
Faranesh, Nabil; Magamseh, Ebrahim; Zaaroura, Suliman; Zeidan, Reem; Shupak, Avi
2017-08-01
To compare the hearing and otoacoustic emissions (OAE) outcome of stapedotomy employing 0.4 and 0.6 mm diameter prostheses. In total, 18 patients with otosclerosis participated in a prospective, double-armed, randomized cohort study. All the patients underwent small fenestra drill stapedotomy employing the Causse fluroplastic large loop piston prostheses. The patients were randomly assigned to groups of 0.4 mm (n=9) and 0.6 mm (n=9) diameter prostheses. The results of pure tone air and bone audiometries, speech audiometry, and OAE conducted 12 months post operatively were compared within and between the groups. The within-group analysis showed significant post-stapedotomy improvements in the average air conduction pure tone thresholds in both groups (52.9±9.6 vs. 25.6±5.2 dB HL; p<0.0001 and 54.6±10.4 vs. 22.2±8.2 dB HL; p<0.0001 for the 0.4 and 0.6 mm groups, respectively) and average air-bone gap (ABG; 37.1±8.5 vs. 8.1±3.9 dB HL; p<0.0001 and 38.3±7.5 vs. 9.9±4.5 dB HL; p<0.0001 in the 0.4 and 0.6 mm groups, respectively). No significant differences were found between the groups in these outcome measures, as well as in the rate of ABG closure within 10 dB HL and the word recognition scores. Favorable outcome in the post-stapedotomy bone conduction (BC) was found for the 0.6 mm prosthesis group, reflecting superior cancellation of the Carhart phenomenon for the 500-3000 Hz pure tone thresholds average (-1.7±3.7 vs. 3.9±6.2 dB HL for the 0.4 and 0.6 mm groups, respectively; p<0.04) and 1000, 2000, and 4000 Hz average (-2.6±4.33 vs. 3.9±7.8 dB HL for the 0.4 and 0.6 mm groups, respectively; p<0.05). Small signal-to-noise ratio (SNR) values of the transient-evoked OAE (TEOAE) and distortion product OAE (DPOAE) were found at baseline and follow-up evaluation with no consistent changes post stapedotomy. Similar post-stapedotomy hearing results were found for the 0.4 and 0.6 mm prostheses with small but statistically significant advantage in BC gain and the overclosure parameter for the 0.6 mm prosthesis. OAE testing was not found to be of clinical value in the evaluation of stapedotomy hearing outcome.
Prevalence and Social Risk Factors for Hearing Impairment in Chinese Children—A National Survey
Yun, Chunfeng; Wang, Zhenjie; Gao, Jiamin; He, Ping; Guo, Chao; Chen, Gong; Zheng, Xiaoying
2017-01-01
Hearing impairment may affect children’s communication skills, social development, and educational achievement. Little is known about the prevalence of hearing impairment among Chinese children. Data were taken from the 2006 second China National Survey on Disability (CNSD). Hearing impairment was defined as moderate (41–60 dB HL), severe (61–80 dB HL), profound (81–90 dB HL), or complete (>91 dB HL). Logistic regression was used to estimate the odds ratio (OR) and 95% confidence intervals (CI). A weighted number of 567,915 hearing impairment children were identified, yielding a prevalence of 17.49 per 10,000 people (95% CI: 16.90–18.08), with prevention or treatment options possible for 64.6% of hearing impairment children. The main causes of hearing impairment were hereditary, tympanitis, and drug intoxication. Illiteracy in one or both parents (mother: OR = 1.388, 95% CI: 1.125–1.714, p < 0.0001; father: OR = 1.537, 95% CI: 1.152–2.049, p < 0.0001 relative to no school or primary school), annual family income lower than national average (OR = 1.323, 95% CI: 1.044–1.675, p = 0.0203, relative to higher than national average), household size larger than three people (OR = 1.432, 95% CI: 1.164–1.762, p = 0.0007, relative to smaller than three people) and single-mother family (OR = 2.056, 95% CI: 1.390–3.042, p = 0.0176, relative to intact family) were the independence risk factors for hearing impairment among Chinese children. Lower annual family income, male children, larger household size, single-mother family, and lower levels of maternal and paternal education were independent risk factors for hearing impairment for Chinese children. Further studies on hearing impairment prevention and the relationship between parental social factors and the risk of hearing impairment are needed. PMID:28106811
Chlorhexidine Prevents Root Dentine Mineral Loss and Fracture Caused by Calcium Hydroxide over Time
Thomaz, Érika Bárbara Abreu Fonseca; Lima, Darlon Martins; Bauer, José
2017-01-01
Purpose. To evaluate the mineral ion loss of root dentine after treatment with 2% chlorhexidine solution (CHX) and to compare its yield and flexural strength (fs) after exposure to calcium hydroxide [Ca(OH)2]. Materials and Methods. Dentine bars (DB) were made from 90 roots of bovine incisors and randomized into three groups: GControl: distilled/deionized water (DDW), GNaOCl: 2.5% sodium hypochlorite + 17% EDTA, and GCHX: CHX + DDW. The release of phosphate (PO4) and calcium (Ca) ions was measured by spectrophotometry. The DB were exposed to Ca(OH)2 paste for 0, 30, 90, and 180 days. DB were subjected to the three-point bending test to obtain yield and fs values. The fracture patterns were evaluated (20x). Data were analyzed using Kruskal-Wallis and Dunn's post hoc tests or one- and two-way ANOVA followed by Tukey's post hoc test (α = 0.05). Results. GCHX showed lower PO43− and Ca2+ ionic release than GNaOCl (p < 0.001). For yield and fs, GCHX > GNaOCl in all periods (p < 0.001), except for yield strength values on 90 days (p = 0.791). A larger frequency of vertical fractures was observed in GNaOCl and that of oblique fractures in GCHX (p < 0.05). Conclusions. CHX prevented PO43− and Ca2+ loss and showed a tendency to preserve the yield and fs of root dentine over time following exposure to Ca(OH)2 paste. PMID:28539937
Extended Range Underwater Loudhailer for Port Security Applications
2006-06-01
and Subtitle Extended Range Underwater Loudhailer for Port Security Applications 6. Performing Organization Code Project No. 5903 7. Author( s ...used in the audio market . The name ‘RCA’ derives from the Radio Corporation of America, which introduced the design, by the early 1940s, to allow...Test June 2005 Test Range (yds) S pe ct ru m B an d Le ve l ( dB re 1 µ P a) S pe ct ru m B an d Le ve l ( dB re 1 µ P a) Figure 9
Target Detection and Identification Using Canonical Correlations Analysis and Subspace Partitioning
2008-04-01
Fig. 2. ROCs for DCC, DCC-P, NNLS, and NNLSP (Present chemical=t1, background= t56 , SNR= 5 dB) alarm, or 1−specificity, and PD is the probability of...discrimination values are given in each ROC plot. In Fig. 2, we use t56 as the background, and t1 as the target chemical. The SNR is 5 dB. For each
Penna, Mario; Velásquez, Nelson; Solís, Rigoberto
2008-04-01
Thresholds for evoked vocal responses and thresholds of multiunit midbrain auditory responses to pure tones and synthetic calls were investigated in males of Pleurodema thaul, as behavioral thresholds well above auditory sensitivity have been reported for other anurans. Thresholds for evoked vocal responses to synthetic advertisement calls played back at increasing intensity averaged 43 dB RMS SPL (range 31-52 dB RMS SPL), measured at the subjects' position. Number of pulses increased with stimulus intensities, reaching a plateau at about 18-39 dB above threshold and decreased at higher intensities. Latency to call followed inverse trends relative to number of pulses. Neural audiograms yielded an average best threshold in the high frequency range of 46.6 dB RMS SPL (range 41-51 dB RMS SPL) and a center frequency of 1.9 kHz (range 1.7-2.6 kHz). Auditory thresholds for a synthetic call having a carrier frequency of 2.1 kHz averaged 44 dB RMS SPL (range 39-47 dB RMS SPL). The similarity between thresholds for advertisement calling and auditory thresholds for the advertisement call indicates that male P. thaul use the full extent of their auditory sensitivity in acoustic interactions, likely an evolutionary adaptation allowing chorusing activity in low-density aggregations.
Risk factors for poor visual outcome in patients with idiopathic intracranial hypertension.
Wall, Michael; Falardeau, Julie; Fletcher, William A; Granadier, Robert J; Lam, Byron L; Longmuir, Reid A; Patel, Anil D; Bruce, Beau B; He, Hua; McDermott, Michael P
2015-09-01
Determine potential risk factors for progressive visual field loss in the Idiopathic Intracranial Hypertension Treatment Trial, a randomized placebo-controlled trial of acetazolamide in patients with idiopathic intracranial hypertension and mild visual loss concurrently receiving a low sodium, weight reduction diet. Logistic regression and classification tree analyses were used to evaluate potential risk factors for protocol-defined treatment failure (>2 dB perimetric mean deviation [PMD] change in patients with baseline PMD -2 to -3.5 dB or >3 dB PMD change with baseline PMD -3.5 to -7 dB). Seven participants (6 on diet plus placebo) met criteria for treatment failure. The odds ratio for patients with grades III to V papilledema vs those with grades I and II was 8.66 (95% confidence interval [CI] 1.65-∞, p = 0.025). A 1-unit decrease in the number of letters correct on the ETDRS (Early Treatment Diabetic Retinopathy Study) chart at baseline was associated with an increase in the odds of treatment failure by a factor of 1.16 (95% CI 1.04-1.30, p = 0.005). Compared with female participants, the odds ratio for male participants was 26.21 (95% CI 1.61-433.00, p = 0.02). The odds of treatment failure were 10.59 times higher (95% CI 1.63-116.83, p = 0.010) for patients with >30 transient visual obscurations per month vs those with ≤30 per month. Male patients, those with high-grade papilledema, and those with decreased visual acuity at baseline were more likely to experience treatment failure. All but one of these patients were treated with diet alone. These patients should be monitored closely and be considered for aggressive treatment of their idiopathic intracranial hypertension. © 2015 American Academy of Neurology.
Wise, L M; Wang, Z; Grynpas, M D
2007-10-01
Fractography has not been fully developed as a useful technique in assessing failure mechanisms of bone. While fracture surfaces of osteonal bone have been explored, this may not apply to conventional mechanical testing of mouse bone. Thus, the focus of this work was to develop and evaluate the efficacy of a fractography protocol for use in supplementing the interpretation of failure mechanisms in mouse bone. Micro-computed tomography and three-point bending were performed on femora of two groups of 6-month-old mice (C57BL/6 and a mixed strain background of 129SV/C57BL6). SEM images of fracture surfaces were collected, and areas of "tension", "compression" and "transition" were identified. Percent areas of roughness were identified and estimated within areas of "tension" and "compression" and subsequently compared to surface roughness measurements generated from an optical profiler. Porosity parameters were determined on the tensile side. Linear regression analysis was performed to evaluate correlations between certain parameters. Results show that 129 mice exhibit significantly increased bone mineral density (BMD), number of "large" pores, failure strength, elastic modulus and energy to failure compared to B6 mice (p<0.001). Both 129 and B6 mice exhibit significantly (p<0.01) more percent areas of tension (49+/-1%, 42+/-2%; respectively) compared to compression (26+/-2%, 31+/-1%; respectively). In terms of "roughness", B6 mice exhibit significantly less "rough" areas (30+/-4%) compared to "smooth" areas (70+/-4%) on the tensile side only (p<0.001). Qualitatively, 129 mice demonstrate more evidence of bone toughening through fiber bridging and loosely connected fiber bundles. The number of large pores is positively correlated with failure strength (p=0.004), elastic modulus (p=0.002) and energy to failure (p=0.041). Percent area of tensile surfaces is positively correlated with failure strength (p<0.001), elastic modulus (p=0.016) and BMD (p=0.037). Percent area of rough compressive surfaces is positively correlated with energy to failure (p=0.039). Evaluation of fracture surfaces has helped to explain why 129 mice have increased mechanical properties compared to B6 mice, namely via toughening mechanisms on the compressive side of failure. Several correlations exist between fractography parameters and mechanical behavior, supporting the utility of fractography with skeletal mouse models.
Kristensen, Jesper T; Houmann, Andreas; Liu, Xiaomin; Turchinovich, Dmitry
2008-06-23
We report on highly reproducible low-loss fusion splicing of polarization-maintaining single-mode fibers (PM-SMFs) and hollow-core photonic crystal fibers (HC-PCFs). The PM-SMF-to-HC-PCF splices are characterized by the loss of 0.62 +/- 0.24 dB, and polarization extinction ratio of 19 +/- 0.68 dB. The reciprocal HC-PCF-to-PM-SMF splice loss is found to be 2.19 +/- 0.33 dB, which is caused by the mode evolution in HC-PCF. The return loss in both cases was measured to be -14 dB. We show that a splice defect is caused by the HC-PCF cleave defect, and the lossy splice can be predicted at an early stage of the splicing process. We also demonstrate that the higher splice loss compromises the PM properties of the splice. Our splicing technique was successfully applied to the realization of a low-loss, environmentally stable monolithic PM fiber laser pulse compressor, enabling direct end-of-the-fiber femtosecond pulse delivery.
Structure/Psychophysical Relationships in X-Linked Retinoschisis.
Bennett, Lea D; Wang, Yi-Zhong; Klein, Martin; Pennesi, Mark E; Jayasundera, Thiran; Birch, David G
2016-02-01
To compare structural properties from spectral-domain optical coherence tomography (SDOCT) and psychophysical measures from a subset of patients enrolled in a larger multicenter natural history study of X-linked retinoschisis (XLRS). A subset of males (n = 24) participating in a larger natural history study of XLRS underwent high-resolution SDOCT. Total retina (TR) thickness and outer segment (OS) thickness were measured manually. Shape discrimination hyperacuity (SDH) and contour integration perimetry (CIP) were performed on an iPad with the myVisionTrack application. Sensitivity was measured with fundus-guided perimetry (4-2 threshold testing strategy; 10-2 grid, spot size 3, 68 points). Correlation was determined with Pearson's r correlation. Values are presented as the mean ± SD. Mean macular OS thickness was less in XLRS patients (17.2 ± 8.1 μm) than in controls (37.1 ± 5.7 μm; P < 0.0001) but mean TR thickness was comparable (P = 0.5884). For patients, total sensitivity was lower (13.2 ± 6.6 dB) than for controls (24.2 ± 2.4 dB; P = 0.0008) and had a strong correlation with photoreceptor OS (R(2) = 0.55, P = 0.0001) and a weak correlation with TR thickness (R(2) = 0.22, P = 0.0158). The XLRS subjects had a logMAR best corrected visual acuity (BCVA) of 0.5 ± 0.3 that was associated with OS (R(2) = 0.79, P < 0.0001) but not TR thickness (R(2) = 0.01, P = 0.6166). Shape DH and CIP inner ring correlated with OS (R(2) = 0.33, P = 0.0085 and R(2) = 0.47, P = 0.0001, respectively) but not TR thickness (R(2) = 0.0004, P = 0.93; R(2) = 0.0043, P = 0.75, respectively). When considered from a single visit, OS thickness within the macula is more closely associated with macular function than TR thickness within the macula in patients with XLRS.
Structure/Psychophysical Relationships in X-Linked Retinoschisis
Bennett, Lea D.; Wang, Yi-Zhong; Klein, Martin; Pennesi, Mark E.; Jayasundera, Thiran; Birch, David G.
2016-01-01
Purpose To compare structural properties from spectral-domain optical coherence tomography (SDOCT) and psychophysical measures from a subset of patients enrolled in a larger multicenter natural history study of X-linked retinoschisis (XLRS). Methods A subset of males (n = 24) participating in a larger natural history study of XLRS underwent high-resolution SDOCT. Total retina (TR) thickness and outer segment (OS) thickness were measured manually. Shape discrimination hyperacuity (SDH) and contour integration perimetry (CIP) were performed on an iPad with the myVisionTrack application. Sensitivity was measured with fundus-guided perimetry (4-2 threshold testing strategy; 10-2 grid, spot size 3, 68 points). Correlation was determined with Pearson's r correlation. Values are presented as the mean ± SD. Results Mean macular OS thickness was less in XLRS patients (17.2 ± 8.1 μm) than in controls (37.1 ± 5.7 μm; P < 0.0001) but mean TR thickness was comparable (P = 0.5884). For patients, total sensitivity was lower (13.2 ± 6.6 dB) than for controls (24.2 ± 2.4 dB; P = 0.0008) and had a strong correlation with photoreceptor OS (R2 = 0.55, P = 0.0001) and a weak correlation with TR thickness (R2 = 0.22, P = 0.0158). The XLRS subjects had a logMAR best corrected visual acuity (BCVA) of 0.5 ± 0.3 that was associated with OS (R2 = 0.79, P < 0.0001) but not TR thickness (R2 = 0.01, P = 0.6166). Shape DH and CIP inner ring correlated with OS (R2 = 0.33, P = 0.0085 and R2 = 0.47, P = 0.0001, respectively) but not TR thickness (R2 = 0.0004, P = 0.93; R2 = 0.0043, P = 0.75, respectively). Conclusions When considered from a single visit, OS thickness within the macula is more closely associated with macular function than TR thickness within the macula in patients with XLRS. PMID:26830370
Simulating Radar Signals for Detection Performance Evaluation.
1981-02-01
defined by g = e-(aO/e 3dB) 2 (70) where a = 1.6651 and 0 3dB Is the one-way half-power heamwidth, we note that from (60) and (68) a=( 03dB) 2 , ( 71 ...8217erform;ice of Some Nonparametric Rank Tests and an Alpplication to Radar," JEEE ’’ra.. Information Theory , Vol. IT-16, pp 309- 318 (c!;pecjally Section...V1 1 1 C . fl I V IC ’A It N FI (.LLTrif -I~d P’LE (,%I I CiRCS-SE CT IC& AREA C vu I$1 i rKI I %1 : 111. C I -PjI Ik ~I G%ft- 71 -Y: I I LAl. I J10F
Morgan, Ryan W; Kilbaugh, Todd J; Shoap, Wesley; Bratinov, George; Lin, Yuxi; Hsieh, Ting-Chang; Nadkarni, Vinay M; Berg, Robert A; Sutton, Robert M
2017-02-01
Most pediatric in-hospital cardiac arrests (IHCAs) occur in ICUs where invasive hemodynamic monitoring is frequently available. Titrating cardiopulmonary resuscitation (CPR) to the hemodynamic response of the individual improves survival in preclinical models of adult cardiac arrest. The objective of this study was to determine if titrating CPR to systolic blood pressure (SBP) and coronary perfusion pressure (CoPP) in a pediatric porcine model of asphyxia-associated ventricular fibrillation (VF) IHCA would improve survival as compared to traditional CPR. After 7min of asphyxia followed by VF, 4-week-old piglets received either hemodynamic-directed CPR (HD-CPR; compression depth titrated to SBP of 90mmHg and vasopressor administration to maintain CoPP ≥20mmHg); or Standard Care (compression depth 1/3 of the anterior-posterior chest diameter and epinephrine every 4min). All animals received CPR for 10min prior to the first defibrillation attempt. CPR was continued for a maximum of 20min. Protocolized intensive care was provided to all surviving animals for 4h. The primary outcome was 4-h survival. Survival rate was greater with HD-CPR (12/12) than Standard Care (6/10; p=0.03). CoPP during HD-CPR was higher compared to Standard Care (point estimate +8.1mmHg, CI 95 : 0.5-15.8mmHg; p=0.04). Chest compression depth was lower with HD-CPR than Standard Care (point estimate -14.0mm, CI95: -9.6 to -18.4mm; p<0.01). Prior to the first defibrillation attempt, more vasopressor doses were administered with HD-CPR vs. Standard Care (median 5 vs. 2; p<0.01). Hemodynamic-directed CPR improves short-term survival compared to standard depth-targeted CPR in a porcine model of pediatric asphyxia-associated VF IHCA. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Morgan, Ryan W.; Kilbaugh, Todd J.; Shoap, Wesley; Bratinov, George; Lin, Yuxi; Hsieh, Ting-Chang; Nadkarni, Vinay M.; Berg, Robert A.; Sutton, Robert M.
2016-01-01
Aim Most pediatric in-hositalcardiac arrests(IHCAs) occur in ICUs where invasive hemodynamic monitoring is frequently available. Titrating cardiopulmonary resuscitation (CPR) to the hemodynamic response of the individual improves survival in preclinical models of adult cardiac arrest. The objective of this study was to determine if titrating CPR to systolic blood pressure (SBP) and coronary perfusion pressure (CoPP) in a pediatric porcine model of asphyxia-associated ventricular fibrillation (VF) IHCA would improve survival as compared to traditional CPR. Methods After 7 minutes of asphyxia followed by VF, 4-week-old piglets received either Hemodynamic-Directed CPR (HD-CPR; compression depth titrated to SBP of 90mmHg and vasopressor administration to maintain CoPP ≥20mmHg); or Standard Care (compression depth 1/3 of the anterior-posterior chest diameter and epinephrine every 4 minutes). All animals received CPR for 10 minutes prior to the first defibrillation attempt. CPR was continued for a maximum of 20 minutes. Protocolized intensive care was provided to all surviving animals for 4 hours. The primary outcome was 4-hour survival. Results Survival rate was greater with HD-CPR (12/12) than Standard Care (6/10; p=0.03). CoPP during HD-CPR was higher compared to Standard Care (point estimate +8.1mmHg, CI95: 0.5–15.8mmHg; p=0.04). Chest compression depth was lower with HD-CPR than Standard Care (point estimate 14.0mm, CI95: 9.6–18.4mm; p<0.01). Prior to the first defibrillation attempt, more vasopressor doses were administered with HD-CPR versus Standard Care (median 5 versus 2; p<0.01). Conclusions Hemodynamic-directed CPR improves short-term survival compared to standard depth-targeted CPR in a porcine model of pediatric asphyxia-associated VF IHCA. PMID:27923692
1975-09-01
unit volume of conductor is: k2 2 dB 2 W" - 1 -PV : •iw2 1d11TII-3- 2 wihen the superconductor is in the normal state and: k - 2 dB I j P/ dB...C 2 -Bc ha 2 + 2 2 ’ -.4) ic ic B ~ h 2 .2t J P(-a~d) - (-• + 2_-- + 1 ) Jc Jc In the region d<x<a Jc =ici and the local power dissipation per unit ... unit length ever the whole of the circu- lar cross section is: ( 1 2 = x dh I4 :ross section
NASA Astrophysics Data System (ADS)
Mun, Jae-Kyoung; Oh, Jung-Hun; Sung, Ho-Kun; Wang, Cong
2015-12-01
The effects of the doping concentration ratios between upper and lower silicon planar-doping layers on the DC and RF characteristics of the double planar doped pseudomorphic high electron mobility transistors (pHEMTs) are investigated. From the device simulation, an increase of maximum extrinsic transconductance and a decrease of total on- and off-state capacitances are observed, as well as an increase of the upper to lower planar-doping concentration ratios (UTLPDR), which give rise to an enhancement of the switching speed and isolation characteristics. On the basis of simulation results, two types of pHEMTs are fabricated with two different UTLPDRs of 4:1 and 1:2. After applying these two types' pHEMTs, single-pole-double-throw (SPDT) transmitter/receiver monolithic microwave integrated circuit (MMIC) switches are also designed and fabricated. The SPDT MMIC switch with a 4:1 UTLPDR shows an insertion loss of 0.58 dB, isolation of 40.2 dB, and switching speed of 100 ns, respectively, which correspondingly indicate a 0.23 dB lower insertion loss, 2.90 dB higher isolation and 2.5 times faster switching speed than those of 1:2 UTLPDR at frequency range of 2-6 GHz. From the simulation results and comparative studies, we propose that the UTLPDR must be greater than 4:1 for the best switching performance. With the abovementioned excellent performances, the proposed switch would be quite promising in the application of information and communications technology system.
Moraska, Albert F.; Hickner, Robert C.; Kohrt, Wendy M.; Brewer, Alan
2012-01-01
Objective To demonstrate proof-of-principle measurement for physiological change within an active myofascial trigger point (MTrP) undergoing trigger point release (ischemic compression). Design Interstitial fluid was sampled continuously at a trigger point before and after intervention. Setting A biomedical research clinic at a university hospital. Participants Two subjects from a pain clinic presenting with chronic headache pain. Interventions A single microdialysis catheter was inserted into an active MTrP of the upper trapezius to allow for continuous sampling of interstitial fluid before and after application of trigger point therapy by a massage therapist. Main Outcome Measures Procedural success, pain tolerance, feasibility of intervention during sample collection, determination of physiologically relevant values for local blood flow, as well as glucose and lactate concentrations. Results Both patients tolerated the microdialysis probe insertion into the MTrP and treatment intervention without complication. Glucose and lactate concentrations were measured in the physiological range. Following intervention, a sustained increase in lactate was noted for both subjects. Conclusions Identifying physiological constituents of MTrP’s following intervention is an important step toward understanding pathophysiology and resolution of myofascial pain. The present study forwards that aim by showing proof-of-concept for collection of interstitial fluid from an MTrP before and after intervention can be accomplished using microdialysis, thus providing methodological insight toward treatment mechanism and pain resolution. Of the biomarkers measured in this study, lactate may be the most relevant for detection and treatment of abnormalities in the MTrP. PMID:22975226
Experimental and Analytical Studies of Shielding Concepts for Point Sources and Jet Noises.
NASA Astrophysics Data System (ADS)
Wong, Raymond Lee Man
This analytical and experimental study explores concepts for jet noise shielding. Model experiments centre on solid planar shields, simulating engine-over-wing installations, and 'sugar scoop' shields. Tradeoff on effective shielding length is set by interference 'edge noise' as the shield trailing edge approaches the spreading jet. Edge noise is minimized by (i) hyperbolic cutouts which trim off the portions of most intense interference between the jet flow and the barrier and (ii) hybrid shields--a thermal refractive extension (a flame); for (ii) the tradeoff is combustion noise. In general, shielding attenuation increases steadily with frequency, following low frequency enhancement by edge noise. Although broadband attenuation is typically only several dB, the reduction of the subjectively weighted perceived noise levels is higher. In addition, calculated ground contours of peak PN dB show a substantial contraction due to shielding: this reaches 66% for one of the 'sugar scoop' shields for the 90 PN dB contour. The experiments are complemented by analytical predictions. They are divided into an engineering scheme for jet noise shielding and more rigorous analysis for point source shielding. The former approach combines point source shielding with a suitable jet source distribution. The results are synthesized into a predictive algorithm for jet noise shielding: the jet is modelled as a line distribution of incoherent sources with narrow band frequency (TURN)(axial distance)('-1). The predictive version agrees well with experiment (1 to 1.5 dB) up to moderate frequencies. The insertion loss deduced from the point source measurements for semi-infinite as well as finite rectangular shields agrees rather well with theoretical calculation based on the exact half plane solution and the superposition of asymptotic closed-form solutions. An approximate theory, the Maggi-Rubinowicz line integral, is found to yield reasonable predictions for thin barriers including cutouts if a certain correction is applied. The more exact integral equation approach (solved numerically) is applied to a more demanding geometry: a half round sugar scoop shield. It is found that the solutions of integral equation derived from Helmholtz formula in normal derivative form show satisfactory agreement with measurements.
Reduced coronary flow and resistance reserve in primary scleroderma myocardial disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nitenberg, A.; Foult, J.M.; Kahan, A.
1986-08-01
The maximum coronary vasodilator capacity after intravenous dipyridamole (0.14 mg X kg-1 X min-1 X 4 minutes) was studied in seven patients with primary scleroderma myocardial disease and compared to that of seven control subjects. Hemodynamic data and left ventricular angiographic data were not different in the two groups. The coronary flow reserve was evaluated by the dipyridamole/basal coronary sinus blood flow ratio (D/B CSBF) and the coronary resistance reserve by the dipyridamole/basal coronary resistance ratio (D/B CR). Coronary reserve was greatly impaired in the group with primary scleroderma myocardial disease: D/B CSBF was lower than in the control groupmore » (2.54 +/- 1.37 vs 4.01 +/- 0.56, respectively; p less than 0.05) and D/B CR was higher than in the control group (0.47 +/- 0.25 vs 0.23 +/- 0.04, respectively; p less than 0.05). Such a decreased coronary flow and resistance reserve in patients with primary scleroderma myocardial disease was not explained by an alteration of left ventricular function. It may be an important contributing factor in the pathogenesis of primary scleroderma myocardial disease.« less
Experimental investigations on airborne gravimetry based on compressed sensing.
Yang, Yapeng; Wu, Meiping; Wang, Jinling; Zhang, Kaidong; Cao, Juliang; Cai, Shaokun
2014-03-18
Gravity surveys are an important research topic in geophysics and geodynamics. This paper investigates a method for high accuracy large scale gravity anomaly data reconstruction. Based on the airborne gravimetry technology, a flight test was carried out in China with the strap-down airborne gravimeter (SGA-WZ) developed by the Laboratory of Inertial Technology of the National University of Defense Technology. Taking into account the sparsity of airborne gravimetry by the discrete Fourier transform (DFT), this paper proposes a method for gravity anomaly data reconstruction using the theory of compressed sensing (CS). The gravity anomaly data reconstruction is an ill-posed inverse problem, which can be transformed into a sparse optimization problem. This paper uses the zero-norm as the objective function and presents a greedy algorithm called Orthogonal Matching Pursuit (OMP) to solve the corresponding minimization problem. The test results have revealed that the compressed sampling rate is approximately 14%, the standard deviation of the reconstruction error by OMP is 0.03 mGal and the signal-to-noise ratio (SNR) is 56.48 dB. In contrast, the standard deviation of the reconstruction error by the existing nearest-interpolation method (NIPM) is 0.15 mGal and the SNR is 42.29 dB. These results have shown that the OMP algorithm can reconstruct the gravity anomaly data with higher accuracy and fewer measurements.
Experimental Investigations on Airborne Gravimetry Based on Compressed Sensing
Yang, Yapeng; Wu, Meiping; Wang, Jinling; Zhang, Kaidong; Cao, Juliang; Cai, Shaokun
2014-01-01
Gravity surveys are an important research topic in geophysics and geodynamics. This paper investigates a method for high accuracy large scale gravity anomaly data reconstruction. Based on the airborne gravimetry technology, a flight test was carried out in China with the strap-down airborne gravimeter (SGA-WZ) developed by the Laboratory of Inertial Technology of the National University of Defense Technology. Taking into account the sparsity of airborne gravimetry by the discrete Fourier transform (DFT), this paper proposes a method for gravity anomaly data reconstruction using the theory of compressed sensing (CS). The gravity anomaly data reconstruction is an ill-posed inverse problem, which can be transformed into a sparse optimization problem. This paper uses the zero-norm as the objective function and presents a greedy algorithm called Orthogonal Matching Pursuit (OMP) to solve the corresponding minimization problem. The test results have revealed that the compressed sampling rate is approximately 14%, the standard deviation of the reconstruction error by OMP is 0.03 mGal and the signal-to-noise ratio (SNR) is 56.48 dB. In contrast, the standard deviation of the reconstruction error by the existing nearest-interpolation method (NIPM) is 0.15 mGal and the SNR is 42.29 dB. These results have shown that the OMP algorithm can reconstruct the gravity anomaly data with higher accuracy and fewer measurements. PMID:24647125
Wang, X H; Mao, T T; Pan, Y Y; Xie, H H; Zhang, H Y; Xiao, J; Jiang, L P
2016-03-01
To observe the expressions of tumor necrosis factor alpha (TNF-α), matrix metalloproteinase 2 (MMP-2) and collagen in local skin tissue of pressure ulcer of rats, and to explore the possible mechanism of the pathogenesis of pressure ulcer. Forty male SD rats were divided into normal control group, 3 d compression group, 5 d compression group, 7 d compression group, and 9 d compression group according to the random number table, with 8 rats in each group. The rats in normal control group did not receive any treatment, whereas the rats in the latter 4 groups were established the deep tissue injury model (3 d compression group) and pressure ulcer model (the other 3 groups) on the gracilis muscle on both hind limbs using a way of cycle compression of ischemia-reperfusion magnet. The rats in 3 d compression group received only three cycles of compression, while the compressed skin of the rats in 5 d compression group, 7 d compression group, and 9 d compression group were cut through and received pressure to 5, 7 and 9 cycles after three cycles of compression, respectively. The rats in 3 d compression group were sacrificed immediately after receiving compression for 3 d (the rats in normal control group were sacrificed at the same time), and the rats in the other 3 groups were respectively sacrificed after receiving compression for 5, 7, and 9 d, and the skin tissue on the central part of gracilis muscle on both hind limbs were harvested. The morphology of the skin tissue was observed with HE staining. The expression of collagen fiber was observed with Masson staining. The expressions of collagen type Ⅳ and MMP-2 were detected by immunohistochemical method. The expressions of TNF-α and phosphorylated NF kappa B (NF-κB) were determined by Western blotting. Data were processed with one-way analysis of variance and LSD test. (1) In normal control group, the skin tissue of rats was stratified squamous epithelium, with the clear skin structure, and there was no obvious infiltration of inflammatory cells. In 3 d compression group, the skin layers of rats were clear, with quite a few fibroblasts, and the inflammatory cells began to infiltrate. In 5 d compression group, 7 d compression group, and 9 d compression group, the epidermis of rats thickened, with the number of fibroblasts reduced, and the infiltration of inflammatory cells enhanced with the compressed time prolonging. (2) In normal control group, the collagen fibers in skin tissue of rats were arranged in order, with rich content. In 3 d compression group, the collagen fibers in skin tissue of rats were arranged orderly, with high expression level, which was similar to that in normal control group (P>0.05). In 5 d compression group and 7 d compression group, the collagen fibers in skin tissue of rats were arranged in disorder, with the expression level gradually reduced, which were significantly lower than that in normal control group (with P values below 0.01). In 9 d compression group, the expression of collagen fiber in skin tissue of rats was a little higher than that in 7 d compression group, but it was still significantly lower than that in normal control group (P<0.01). (3) The expressions of collagen type Ⅳ in skin tissue of rats in normal control group, 3 d compression group, 5 d compression group, 7 d compression group, and 9 d compression group were respectively 11.0±2.8, 9.0±1.7, 8.3±2.8, 5.1±1.8, and 5.4±1.2. The expression of collagen type Ⅳ in skin tissue of rats in 3 d compression group was similar to that in normal control group (P>0.05). The expressions of collagen type Ⅳ in skin tissue of rats in 5 d compression group, 7 d compression group, and 9 d compression group were significantly lower than that in normal control group (P<0.05 or P<0.01). The expression of MMP-2 in skin tissue of rats in 3 d compression group was similar to that in normal control group (P>0.05). The expressions of MMP-2 in skin tissue of rats in 5 d compression group, 7 d compression group, and 9 d compression group were significantly higher than that in normal control group (P<0.05 or P<0.01). (4) The expression of TNF-α in skin tissue of rats in normal control group was 0.48±0.11, and the expressions of TNF-α in skin tissue of rats in 3 d compression group, 5 d compression group, 7 d compression group, and 9 d compression group were respectively 0.84±0.08, 1.13±0.19, 1.34±0.16, and 1.52±0.23, which were all significantly higher than that in normal control group (with P values below 0.01). The expressions of phosphorylated NF-κB in skin tissue of rats in 3 d compression group and 9 d compression group were similar to that in normal control group (with P values above 0.05), and the expressions of phosphorylated NF-κB in skin tissue of rats in 5 d compression group and 7 d compression group were significantly higher than that in normal control group (P<0.05 or P<0.01). The high expression of MMP-2 and reduction of collagen induced by inflammatory reaction mediated by the high expression of TNF-α in local skin tissue of pressure ulcer of rats may be one of the important reasons for the formation of pressure ulcer.
Neutral endopeptidase inhibition in diabetic wound repair.
Spenny, Michelle L; Muangman, Pornprom; Sullivan, Stephen R; Bunnett, Nigel W; Ansel, John C; Olerud, John E; Gibran, Nicole S
2002-01-01
In response to cutaneous injury, sensory nerves release substance P, a proinflammatory neuropeptide. Substance P stimulates mitogenesis and migration of keratinocytes, fibroblasts, and endothelial cells. Neutral endopeptidase (NEP), a cell surface metallopeptidase, degrades substance P. Chronic nonhealing wounds and skin from patients with diabetes mellitus show increased NEP localization and activity. We hypothesized that increased NEP may retard wound healing and that NEP inhibition would improve closure kinetics in an excisional murine wound model. NEP enzyme activity was measured in skin samples from mutant diabetic mice (db/db) and nondiabetic (db/-) littermates by degradation of glutaryl-ala-ala-phe-4-methoxy-2-naphthylamine. Full-thickness 6-mm dorsal excisional wounds treated with normal saline or the NEP inhibitor thiorphan (10 microM or 25 microM) for 7 days were followed until closure. Histological examination and NEP activity were evaluated in a subset of wounds. NEP activity in unwounded db/db skin (20.6 pmol MNA/hr/ microg) significantly exceeded activity in db/-skin (7.9 pmol MNA/hr/ microg; p = 0.02). In db/db mice, 25 microM thiorphan shortened time to closure (18.0 days; p < 0.05) compared to normal saline (23.5 days). NEP inhibition did not alter closure kinetics in db/-mice. While the inflammatory response appeared enhanced in early wounds treated with thiorphan, blinded histological scoring of healed wounds using a semiquantitative scale showed no difference in inflammation. Unwounded skin from diabetic mice shows increased NEP activity and NEP inhibition improved wound closure kinetics without affecting contraction, suggesting that its principal effect was to augment epithelialization.
Physicsdesign point for a 1MW fusion neutron source
NASA Astrophysics Data System (ADS)
Woodruff, Simon; Melnik, Paul; Sieck, Paul; Stuber, James; Romero-Talamas, Carlos; O'Bryan, John; Miller, Ronald
2016-10-01
We are developing a design point for a spheromak experiment heated by adiabatic compression for use as a compact neutron source. We utilize the CORSICA and NIMROD MHD codes as well as analytic modeling to assess a concept with target parameters R0 =0.5m, Rf =0.17m, T0 =1keV, Tf =8keV, n0 =2e20m-3 and nf = 5e21m-3, with radial convergence of C =R0/Rf =3. We present results from CORSICA showing the placement of coils and passive structure to ensure stability during compression. We specify target parameters for the compression in terms of plasma beta, formation efficiency and energy confinement. We present results simulations of magnetic compression using the NIMROD code to examine the role of rotation on the stability and confinement of the spheromak as it is compressed. Supported by DARPA Grant N66001-14-1-4044 and IAEA CRP on Compact Fusion Neutron Sources.
Dou, Lin; Wang, Shuyue; Sun, Libo; Huang, Xiuqing; Zhang, Yang; Shen, Tao; Guo, Jun; Man, Yong; Tang, Weiqing; Li, Jian
2017-01-01
Insulin resistance is a critical factor contributing to the pathogenesis of type 2 diabetes and other metabolic diseases. Recent studies have indicated that miR-338-3p plays an important role in cancer. Here, we investigated whether miR-338-3p mediates tumour necrosis factor-α (TNF-α)-induced hepatic insulin resistance. The activation of the insulin signalling pathway and the level of glycogenesis were examined in the livers of the db/db and high fat diet (HFD)-fed mice and in HEP1-6 cells transfected with miR-338-3p mimic or inhibitor. Computational prediction of microRNA target, luciferase assay and Western blot were used to assess the miR-338-3p target. Chromatin immunoprecipitation (ChIP) assay was used to determine the transcriptional regulator of miR-338-3p. miR-338-3p was down-regulated in the livers of the db/db, HFD-fed and TNF-α-treated C57BL/6J mice, as well as in mouse HEP1-6 hepatocytes treated with TNF-α. Importantly the down-regulation of miR-338-3p induced insulin resistance, as indicated by impaired glucose tolerance and insulin tolerance. Further research showed that the down-regulated miR-338-3p resulted in the impaired AKT/ glycogen synthase kinase 3 beta (GSl·Gβ) signalling pathway and glycogen synthesis. In contrast, hepatic over-expression of miR-338-3p rescued the TNF-α-induced insulin resistance. Moreover, protein phosphatase 4 regulator subunit 1 (PP4R1) was identified as a direct target of miR-338-3p that mediated hepatic insulin signalling by regulating protein phosphatase 4 (PP4). Finally we identified hepatic nuclear factor 4 alpha (HNF-4α) as the transcriptional regulator of miRNA-338-3p. Our studies provide novel insight into the critical role and molecular mechanism by which miR-338-3p is involved in TNF-α-induced hepatic insulin resistance. miR-338-3p might mediate TNF-α-induced hepatic insulin resistance by targeting PP4R1 to regulate PP4 expression. © 2017 The Author(s). Published by S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Juan; Li, Li; Yun, Hui-fang
2015-08-07
Background: Diabetic vascular smooth muscle cells (VSMCs) exhibit significantly increased rates of proliferation and migration, which was the most common pathological change in atherosclerosis. In addition, the study about the role for miRNAs in the regulation of VSMC proliferation is just beginning to emerge and additional miRNAs involved in VSMC proliferation modulation should be identified. Methods: The expression of miR-138 and SIRT1 were examined in SMCs separated from db/db mice and in SMC lines C-12511 exposed to high glucose with qRT-PCR and western blot. The regulation of miR-138 on the expression of SMCs was detected with luciferase report assay. VSMCsmore » proliferation and migration assays were performed to examine the effect of miR-138 inhibitor on VSMCs proliferation and migration. Results: We discovered that higher mRNA level of miR-138 and reduced expression of SIRT1 were observed in SMCs separated from db/db mice and in SMC lines C-12511. Moreover, luciferase report assay showed that the activity of SIRT1 3′-UTR was highly increased by miR-138 inhibitor and reduced by miR-138 mimic. In addition, we examined that the up-regulation of NF-κB induced by high glucose in SMCs was reversed by resveratrol and miR-138 inhibitor. MTT and migration assays showed that miR-138 inhibitor attenuated the proliferation and migration of smooth muscle cells. Conclusion: In this study, we revealed that miR-138 might promote proliferation and migration of SMC in db/db mice through suppressing the expression of SIRT1. - Highlights: • Higher mRNA level of miR-138 was observed in SMCs from db/db mice. • The mRNA and protein level of SIRT1 in SMCs from db/db mice were greatly reduced. • miR-138 could regulate the expression of SIRT1 in SMCs. • SIRT1 overexpression reversed the up-regulation of acetylized p65 and NF-κB induced by high glucose. • MiR-138 inhibitor reversed VSMCs proliferation and migration induced by high glucose.« less
Adaptive bit plane quadtree-based block truncation coding for image compression
NASA Astrophysics Data System (ADS)
Li, Shenda; Wang, Jin; Zhu, Qing
2018-04-01
Block truncation coding (BTC) is a fast image compression technique applied in spatial domain. Traditional BTC and its variants mainly focus on reducing computational complexity for low bit rate compression, at the cost of lower quality of decoded images, especially for images with rich texture. To solve this problem, in this paper, a quadtree-based block truncation coding algorithm combined with adaptive bit plane transmission is proposed. First, the direction of edge in each block is detected using Sobel operator. For the block with minimal size, adaptive bit plane is utilized to optimize the BTC, which depends on its MSE loss encoded by absolute moment block truncation coding (AMBTC). Extensive experimental results show that our method gains 0.85 dB PSNR on average compare to some other state-of-the-art BTC variants. So it is desirable for real time image compression applications.
Medical Ultrasound Video Coding with H.265/HEVC Based on ROI Extraction
Wu, Yueying; Liu, Pengyu; Gao, Yuan; Jia, Kebin
2016-01-01
High-efficiency video compression technology is of primary importance to the storage and transmission of digital medical video in modern medical communication systems. To further improve the compression performance of medical ultrasound video, two innovative technologies based on diagnostic region-of-interest (ROI) extraction using the high efficiency video coding (H.265/HEVC) standard are presented in this paper. First, an effective ROI extraction algorithm based on image textural features is proposed to strengthen the applicability of ROI detection results in the H.265/HEVC quad-tree coding structure. Second, a hierarchical coding method based on transform coefficient adjustment and a quantization parameter (QP) selection process is designed to implement the otherness encoding for ROIs and non-ROIs. Experimental results demonstrate that the proposed optimization strategy significantly improves the coding performance by achieving a BD-BR reduction of 13.52% and a BD-PSNR gain of 1.16 dB on average compared to H.265/HEVC (HM15.0). The proposed medical video coding algorithm is expected to satisfy low bit-rate compression requirements for modern medical communication systems. PMID:27814367
Medical Ultrasound Video Coding with H.265/HEVC Based on ROI Extraction.
Wu, Yueying; Liu, Pengyu; Gao, Yuan; Jia, Kebin
2016-01-01
High-efficiency video compression technology is of primary importance to the storage and transmission of digital medical video in modern medical communication systems. To further improve the compression performance of medical ultrasound video, two innovative technologies based on diagnostic region-of-interest (ROI) extraction using the high efficiency video coding (H.265/HEVC) standard are presented in this paper. First, an effective ROI extraction algorithm based on image textural features is proposed to strengthen the applicability of ROI detection results in the H.265/HEVC quad-tree coding structure. Second, a hierarchical coding method based on transform coefficient adjustment and a quantization parameter (QP) selection process is designed to implement the otherness encoding for ROIs and non-ROIs. Experimental results demonstrate that the proposed optimization strategy significantly improves the coding performance by achieving a BD-BR reduction of 13.52% and a BD-PSNR gain of 1.16 dB on average compared to H.265/HEVC (HM15.0). The proposed medical video coding algorithm is expected to satisfy low bit-rate compression requirements for modern medical communication systems.
Logic programming to infer complex RNA expression patterns from RNA-seq data.
Weirick, Tyler; Militello, Giuseppe; Ponomareva, Yuliya; John, David; Döring, Claudia; Dimmeler, Stefanie; Uchida, Shizuka
2018-03-01
To meet the increasing demand in the field, numerous long noncoding RNA (lncRNA) databases are available. Given many lncRNAs are specifically expressed in certain cell types and/or time-dependent manners, most lncRNA databases fall short of providing such profiles. We developed a strategy using logic programming to handle the complex organization of organs, their tissues and cell types as well as gender and developmental time points. To showcase this strategy, we introduce 'RenalDB' (http://renaldb.uni-frankfurt.de), a database providing expression profiles of RNAs in major organs focusing on kidney tissues and cells. RenalDB uses logic programming to describe complex anatomy, sample metadata and logical relationships defining expression, enrichment or specificity. We validated the content of RenalDB with biological experiments and functionally characterized two long intergenic noncoding RNAs: LOC440173 is important for cell growth or cell survival, whereas PAXIP1-AS1 is a regulator of cell death. We anticipate RenalDB will be used as a first step toward functional studies of lncRNAs in the kidney.
Huang, Le; You, Yong-Ke; Zhu, Tracy Y; Zheng, Li-Zhen; Huang, Xiao-Ru; Chen, Hai-Yong; Yao, Dong; Lan, Hui-Yao; Qin, Ling
2016-06-10
This study aimed to evaluate the validation of the leptin receptor-deficient mice model for secondary osteoporosis associated with type 2 diabetes mellitus (T2DM) at bone micro-architectural level. Thirty three 36-week old male mice were divided into four groups: normal control (db/m) (n = 7), leptin receptor-deficient T2DM (db/db) (n = 8), human C-reactive protein (CRP) transgenic normal control (crp/db/m) (n = 7), and human CRP transgenic T2DM (crp/db/db) (n = 11). Lumber vertebrae (L5) and bilateral lower limbs were scanned by micro-CT to analyze trabecular and cortical bone quality. Right femora were used for three-point bending to analyze the mechanical properties. Trabecular bone quality at L5 was better in db/db or crp/db/db group in terms of bone mineral density (BMD), bone volume fraction, connectivity density, trabecular number and separation (all p < 0.05). However the indices measured at proximal tibia showed comparable trabecular BMD and microarchitecture among the four groups. Femur length in crp/db/db group was significantly shorter than db/m group (p < 0.05) and cortices were thinner in db/db and crp/db/db groups (p > 0.05). Maximum loading and energy yield in mechanical test were similar among groups while the elastic modulus in db/db and crp/db/db significantly lower than db/m. The leptin-receptor mice is not a proper model for secondary osteoporosis associated with T2DM.
NASA Astrophysics Data System (ADS)
Huang, Le; You, Yong-Ke; Zhu, Tracy Y.; Zheng, Li-Zhen; Huang, Xiao-Ru; Chen, Hai-Yong; Yao, Dong; Lan, Hui-Yao; Qin, Ling
2016-06-01
This study aimed to evaluate the validation of the leptin receptor-deficient mice model for secondary osteoporosis associated with type 2 diabetes mellitus (T2DM) at bone micro-architectural level. Thirty three 36-week old male mice were divided into four groups: normal control (db/m) (n = 7), leptin receptor-deficient T2DM (db/db) (n = 8), human C-reactive protein (CRP) transgenic normal control (crp/db/m) (n = 7), and human CRP transgenic T2DM (crp/db/db) (n = 11). Lumber vertebrae (L5) and bilateral lower limbs were scanned by micro-CT to analyze trabecular and cortical bone quality. Right femora were used for three-point bending to analyze the mechanical properties. Trabecular bone quality at L5 was better in db/db or crp/db/db group in terms of bone mineral density (BMD), bone volume fraction, connectivity density, trabecular number and separation (all p < 0.05). However the indices measured at proximal tibia showed comparable trabecular BMD and microarchitecture among the four groups. Femur length in crp/db/db group was significantly shorter than db/m group (p < 0.05) and cortices were thinner in db/db and crp/db/db groups (p > 0.05). Maximum loading and energy yield in mechanical test were similar among groups while the elastic modulus in db/db and crp/db/db significantly lower than db/m. The leptin-receptor mice is not a proper model for secondary osteoporosis associated with T2DM.
Iron under conditions close to the α - γ - ɛ triple point
NASA Astrophysics Data System (ADS)
Dewaele, Agnès; Svitlyk, Volodymyr; Bottin, François; Bouchet, Johann; Jacobs, Jeroen
2018-05-01
The stability domains and equations of state of α-Fe, ɛ-Fe, and γ-Fe have been measured using X-ray diffraction under conditions close to their triple point: 7 ≤ P ≤ 20 GPa and 480 ≤ T ≤ 820 K. Special attention was paid to ensure the hydrostatic compression of the sample, which was a single crystal at start. Narrow α - γ and α - ɛ coexistence domains were observed, while the γ - ɛ transformation appeared sluggish. The triple point is measured at 8.7 ± 1.0 GPa and 750 ± 30 K. Anharmonic effects are evidenced in the equation of state of ɛ-Fe and partly reproduced using ab initio molecular dynamics simulations.
Mozaffari, Mahmood S; Abdelsayed, Rafik; Liu, Jun Yao; Zakhary, Ibrahim; Baban, Babak
2012-02-01
Hallmark features of type 2 diabetes mellitus include glucosuria and polyuria. Further, renal aquaporin 2 is pivotal to regulation of fluid excretion and urine osmolality. Accordingly, we tested the hypothesis that the db/db mouse displays increased glucosuria and fluid excretion but reduced urine osmolality in association with decreased renal aquaporin 2 level. In addition, we examined the effect of chromium picolinate (Cr(pic)3) which is purported to improve glycemic control. The db/db mice excreted more urine in association with marked glucose excretion but lower urine osmolality than db/m control group. Light microscopic examination of renal tissue revealed proliferation of tubular structures in db/db compared to the db/m mice, a feature validated with Ki67 immunostaining. Further, these tubules showed generally similar immunostaining intensity and pattern for aquaporin 2 indicating that proliferated tubules are of distal origin. On the other hand, renal aquaporin 2 protein level was significantly higher in the db/db than db/m group. Treatment of db/db mice with Cr(pic)3 reduced plasma glucose and hemoglobin A1c (~15-17%, p<0.05) and Ki67 positive cells but other parameters were similar to their untreated counterparts. Collectively, these findings suggest that proliferation of renal distal tubules and increased aquaporin 2 level likely represent an adaptive mechanism to regulate fluid excretion to prevent dehydration in the setting of marked glucosuria in the db/db mouse, features not affected by Cr(pic)3 treatment. These observations are of relevance to increasing interest in developing therapeutic agents that facilitate renal glucose elimination. Copyright © 2011 Elsevier Inc. All rights reserved.
Mozaffari, Mahmood S.; Abdelsayed, Rafik; Liu, Jun Yao; Zakhary, Ibrahim; Baban, Babak
2011-01-01
Hallmark features of type 2 diabetes mellitus include glucosuria and polyuria. Further, renal aquaporin 2 is pivotal to regulation of fluid excretion and urine osmolality. Accordingly, we tested the hypothesis that the db/db mouse displays increased glucosuria and fluid excretion but reduced urine osmolality in association with decreased renal aquaporin 2 level. In addition, we examined the effect of chromium picolinate (Cr(pic)3) which is purported to improve glycemic control. The db/db mice excreted more urine in association with marked glucose excretion but lower urine osmolality than db/m control group. Light microscopic examination of renal tissue revealed proliferation of tubular structures in db/db compared to the db/m mice, a feature validated with Ki67 immunostaining. Further, these tubules showed generally similar immunostaining intensity and pattern for aquaporin 2 indicating that proliferated tubules are of distal origin. On the other hand, renal aquaporin 2 protein level was significantly higher in the db/db than db/m group. Treatment of db/db mice with Cr(pic)3 reduced plasma glucose and hemoglobin A1c (~ 15–17%, p<0.05) and Ki67 positive cells but other parameters were similar to their untreated counterparts. Collectively, these findings suggest that proliferation of renal distal tubules and increased aquaporin 2 level likely represent an adaptive mechanism to regulate fluid excretion to prevent dehydration in the setting of marked glucosuria in the db/db mouse, features not affected by Cr(pic)3 treatment. These observations are of relevance to increasing interest in developing therapeutic agents that facilitate renal glucose elimination. PMID:21983138
Enhanced microwave shielding and mechanical properties of high loading MWCNT-epoxy composites
NASA Astrophysics Data System (ADS)
Singh, B. P.; Prasanta; Choudhary, Veena; Saini, Parveen; Pande, Shailaja; Singh, V. N.; Mathur, R. B.
2013-04-01
Dispersion of high loading of carbon nanotubes (CNTs) in epoxy resin is a challenging task for the development of efficient and thin electromagnetic interference (EMI) shielding materials. Up to 20 wt% of multiwalled carbon nanotubes (MWCNTs) loading in the composite was achieved by forming CNT prepreg in the epoxy resin as a first step. These prepreg laminates were then compression molded to form composites which resulted in EMI shielding effectiveness of -19 dB for 0.35 mm thick film and -60 dB at for 1.75 mm thick composites in the X-band (8.2-12.4 GHz). One of the reasons for such high shielding is attributed to the high electrical conductivity of the order of 9 S cm-1 achieved in these composites which is at least an order of magnitude higher than previously reported results at this loading. In addition, an improvement of 40 % in the tensile strength over the neat resin value is observed. Thermal conductivity of the MWCNTs-epoxy composite reached 2.18 W/mK as compared to only 0.14 W/mK for cured epoxy.
Application of automatic gain control for radiometer diagnostic in SST-1 tokamak.
Makwana, Foram R; Siju, Varsha; Edappala, Praveenlal; Pathak, S K
2017-12-01
This paper describes the characterisation of a negative feedback type of automatic gain control (AGC) circuit that will be an integral part of the heterodyne radiometer system operating at a frequency range of 75-86 GHz at SST-1 tokamak. The developed AGC circuit is a combination of variable gain amplifier and log amplifier which provides both gain and attenuation typically up to 15 dB and 45 dB, respectively, at a fixed set point voltage and it has been explored for the first time in tokamak radiometry application. The other important characteristics are that it exhibits a very fast response time of 390 ns to understand the fast dynamics of electron cyclotron emission and can operate at very wide input RF power dynamic range of around 60 dB that ensures signal level within the dynamic range of the detection system.
LNA with wide range of gain control and wideband interference rejection
NASA Astrophysics Data System (ADS)
Wang, Jhen-Ji; Chen, Duan-Yu
2016-10-01
This work presents a low-noise amplifier (LNA) design with a wide-range gain control characteristic that integrates adjustable current distribution and output impedance techniques. For a given gain characteristic, the proposed LNA provides better wideband interference rejection performance than conventional LNA. Moreover, the proposed LNA also has a wider gain control range than conventional LNA. Therefore, it is suitable for satellite communications systems. The simulation results demonstrate that the voltage gain control range is between 14.5 and 34.2 dB for such applications (2600 MHz); the input reflection coefficient is less than -18.9 dB; the noise figure (NF) is 1.25 dB; and the third-order intercept point (IIP3) is 4.52 dBm. The proposed LNA consumes 23.85-28.17 mW at a supply voltage of 1.8 V. It is implemented by using TSMC 0.18-um RF CMOS process technology.
Compression Limit of Two-Dimensional Water Constrained in Graphene Nanocapillaries.
Zhu, YinBo; Wang, FengChao; Bai, Jaeil; Zeng, Xiao Cheng; Wu, HengAn
2015-12-22
Evaluation of the tensile/compression limit of a solid under conditions of tension or compression is often performed to provide mechanical properties that are critical for structure design and assessment. Algara-Siller et al. recently demonstrated that when water is constrained between two sheets of graphene, it becomes a two-dimensional (2D) liquid and then is turned into an intriguing monolayer solid with a square pattern under high lateral pressure [ Nature , 2015 , 519 , 443 - 445 ]. From a mechanics point of view, this liquid-to-solid transformation characterizes the compression limit (or metastability limit) of the 2D monolayer water. Here, we perform a simulation study of the compression limit of 2D monolayer, bilayer, and trilayer water constrained in graphene nanocapillaries. At 300 K, a myriad of 2D ice polymorphs (both crystalline-like and amorphous) are formed from the liquid water at different widths of the nanocapillaries, ranging from 6.0 to11.6 Å. For monolayer water, the compression limit is typically a few hundred MPa, while for the bilayer and trilayer water, the compression limit is 1.5 GPa or higher, reflecting the ultrahigh van der Waals pressure within the graphene nanocapillaries. The compression-limit (phase) diagram is obtained at the nanocapillary width versus pressure (h-P) plane, based on the comprehensive molecular dynamics simulations at numerous thermodynamic states as well as on the Clapeyron equation. Interestingly, the compression-limit curves exhibit multiple local minima.
Coding gains and error rates from the Big Viterbi Decoder
NASA Technical Reports Server (NTRS)
Onyszchuk, I. M.
1991-01-01
A prototype hardware Big Viterbi Decoder (BVD) was completed for an experiment with the Galileo Spacecraft. Searches for new convolutional codes, studies of Viterbi decoder hardware designs and architectures, mathematical formulations, and decompositions of the deBruijn graph into identical and hierarchical subgraphs, and very large scale integration (VLSI) chip design are just a few examples of tasks completed for this project. The BVD bit error rates (BER), measured from hardware and software simulations, are plotted as a function of bit signal to noise ratio E sub b/N sub 0 on the additive white Gaussian noise channel. Using the constraint length 15, rate 1/4, experimental convolutional code for the Galileo mission, the BVD gains 1.5 dB over the NASA standard (7,1/2) Maximum Likelihood Convolution Decoder (MCD) at a BER of 0.005. At this BER, the same gain results when the (255,233) NASA standard Reed-Solomon decoder is used, which yields a word error rate of 2.1 x 10(exp -8) and a BER of 1.4 x 10(exp -9). The (15, 1/6) code to be used by the Cometary Rendezvous Asteroid Flyby (CRAF)/Cassini Missions yields 1.7 dB of coding gain. These gains are measured with respect to symbols input to the BVD and increase with decreasing BER. Also, 8-bit input symbol quantization makes the BVD resistant to demodulated signal-level variations which may cause higher bandwidth than the NASA (7,1/2) code, these gains are offset by about 0.1 dB of expected additional receiver losses. Coding gains of several decibels are possible by compressing all spacecraft data.
Oil point and mechanical behaviour of oil palm kernels in linear compression
NASA Astrophysics Data System (ADS)
Kabutey, Abraham; Herak, David; Choteborsky, Rostislav; Mizera, Čestmír; Sigalingging, Riswanti; Akangbe, Olaosebikan Layi
2017-07-01
The study described the oil point and mechanical properties of roasted and unroasted bulk oil palm kernels under compression loading. The literature information available is very limited. A universal compression testing machine and vessel diameter of 60 mm with a plunger were used by applying maximum force of 100 kN and speed ranging from 5 to 25 mm min-1. The initial pressing height of the bulk kernels was measured at 40 mm. The oil point was determined by a litmus test for each deformation level of 5, 10, 15, 20, and 25 mm at a minimum speed of 5 mmmin-1. The measured parameters were the deformation, deformation energy, oil yield, oil point strain and oil point pressure. Clearly, the roasted bulk kernels required less deformation energy compared to the unroasted kernels for recovering the kernel oil. However, both kernels were not permanently deformed. The average oil point strain was determined at 0.57. The study is an essential contribution to pursuing innovative methods for processing palm kernel oil in rural areas of developing countries.
Fabrication of arc-induced long-period gratings in different silica fibers
NASA Astrophysics Data System (ADS)
Ranjan, Rajeev; Esposito, Flavio; Campopiano, Stefania; Iadicicco, Agostino
2017-05-01
In this work, we report on recent results about the fabrication of Long Period Gratings (LPGs) in different single mode optical fibers, by means of Electric Arc Discharge (EAD) technique. In particular, the results are related to three optical fibers with different doping elements, i.e.: standard telecommunication Ge-doped SMF28, highly photosensitive B/Gecodoped PS1250/1500, and P-doped P-SM-5 fibers. EAD leads to a point-by-point LPG inscription, due to localized tapering of the transversal size of the core and cladding regions along the fiber, and to changes of the silica refractive index due to the stress relaxation induced by local hot spots. Here, we take into consideration both standard and unconventional silica fibers and the aim of the work is to identify an appropriate "recipe" for each fiber, for manufacturing LPGs with strong and narrow attenuation bands (depth higher than 25 dB) and trivial power losses (<0.5 dB). Indeed, a proper combination of arc power and duration, as well as fiber tension, allows for the appropriate core and cladding modulation and thus for the desired LPGs spectral features. The sensitivity characteristics towards surrounding refractive index (SRI) and temperature changes of these LPGs are also investigated, highlighting the effects of different kind of doping.
Asare, George Awuku; Adjei, Samuel; Afriyie, Daniel; Appiah-Danquah, Akua Bempomaa; Asia, Jonas; Asiedu, Bernice; Santa, Sheila; Doku, Derek
2015-12-01
Cardiovascular disease (CVD) accounts for 17.3 million deaths per year globally. In Ghana, CVD accounts for 22.2% of deaths. Croton membranaceus (CM) Mull. Arg. (Euphorbiaceae), a medicinal plant in Ghana is mainly used traditionally for the treatment of benign prostatic hyperplasia and measles. However, some hypoglycaemic and hypotensive effects have recently been reported but not scientifically examined. The study aimed at establishing whether Croton membranaceus (CM) used for prostatitis had any effect on CVD markers. In experiment 1, lipid profile changes were determined. Twenty four male Spontaneously Hypertensive Rats (SHR) were divided into 4 groups. Low (LD), intermediate (ID) and high dose (HD) groups received 25, 50 and 100 mg/kg b.wt. CM aqueous root extracts (CMARE) for 60 days, respectively, the controls received distilled water. In experiment 2, blood glucose levels (BGL) were determined. 21 db/db mice were divided into 3 groups of 7 mice each alongside db/+ mice (7) (negative control). Groups 1 and 2 received 250 mg/kg b.wt CMARE and metformin, respectively. Group 3 (positive control) and db/+ mice (negative control) received distilled water. Mice were monitored for 15 hours. Data collected were analysed using SPSS version 20. Hypotriglyceridaemic effect was observed (p=0.005). High Density Lipoprotein cholesterol (HDL) and Low Density Lipoprotein cholesterol (LDL) showed significant increases (p=0.013) and decreases (p=0.003), respectively. A significant CRP reduction was observed for ID and HD groups (p = 0.010, p = 0.011, respectively). BGL was reduced in Metformin and Croton groups (p=0.000; p= 0.006, respectively) after 3 hours. In conclusion, CMARE has positive effects on some CVD biomarkers and a hypoglycaemic effect.
Adjei, Samuel; Afriyie, Daniel; Appiah-Danquah, Akua Bempomaa; Asia, Jonas; Asiedu, Bernice; Santa, Sheila; Doku, Derek
2015-01-01
Introduction Cardiovascular disease (CVD) accounts for 17.3 million deaths per year globally. In Ghana, CVD accounts for 22.2% of deaths. Croton membranaceus (CM) Mull. Arg. (Euphorbiaceae), a medicinal plant in Ghana is mainly used traditionally for the treatment of benign prostatic hyperplasia and measles. However, some hypoglycaemic and hypotensive effects have recently been reported but not scientifically examined. Aim The study aimed at establishing whether Croton membranaceus (CM) used for prostatitis had any effect on CVD markers. Materials and Methods In experiment 1, lipid profile changes were determined. Twenty four male Spontaneously Hypertensive Rats (SHR) were divided into 4 groups. Low (LD), intermediate (ID) and high dose (HD) groups received 25, 50 and 100 mg/kg b.wt. CM aqueous root extracts (CMARE) for 60 days, respectively, the controls received distilled water. In experiment 2, blood glucose levels (BGL) were determined. 21 db/db mice were divided into 3 groups of 7 mice each alongside db/+ mice (7) (negative control). Groups 1 and 2 received 250 mg/kg b.wt CMARE and metformin, respectively. Group 3 (positive control) and db/+ mice (negative control) received distilled water. Mice were monitored for 15 hours. Data collected were analysed using SPSS version 20. Results Hypotriglyceridaemic effect was observed (p=0.005). High Density Lipoprotein cholesterol (HDL) and Low Density Lipoprotein cholesterol (LDL) showed significant increases (p=0.013) and decreases (p=0.003), respectively. A significant CRP reduction was observed for ID and HD groups (p = 0.010, p = 0.011, respectively). BGL was reduced in Metformin and Croton groups (p=0.000; p= 0.006, respectively) after 3 hours. Conclusion In conclusion, CMARE has positive effects on some CVD biomarkers and a hypoglycaemic effect. PMID:26816938
NASA Astrophysics Data System (ADS)
Damberg, W.; Floegel, K.; Sahm, A.
1983-02-01
A noise reduction device for pneumatic nailers was developed. Conditions of use, range of products available, market regulations and measuring methods were studied. Ease of operation, service life, functional reliability and maintenance capacity were studied. Results show that the essential noise sources of the device are the compressed air blasts of the working and relation phases and the impact of the piston on the bumper. Packages of measures implemented on a laboratory scale indicate noise reduction possibilities for nailers in the short, medium and long term. The sound level of a single shot can be reduced from 110 dB to 93 dB.
Near-toll quality digital speech transmission in the mobile satellite service
NASA Technical Reports Server (NTRS)
Townes, S. A.; Divsalar, D.
1986-01-01
This paper discusses system considerations for near-toll quality digital speech transmission in a 5 kHz mobile satellite system channel. Tradeoffs are shown for power performance versus delay for a 4800 bps speech compression system in conjunction with a 16 state rate 2/3 trellis coded 8PSK modulation system. The suggested system has an additional 150 ms of delay beyond the propagation delay and requires an E(b)/N(0) of about 7 dB for a Ricean channel assumption with line-of-sight to diffuse component ratio of 10 assuming ideal synchronization. An additional loss of 2 to 3 dB is expected for synchronization in fading environment.
Murgier, J; Cassard, X
2014-05-01
Cryotherapy is a useful adjunctive analgesic measure in patients with postoperative pain following anterior cruciate ligament (ACL) surgery. Either static permanent compression or dynamic intermittent compression can be added to increase the analgesic effect of cryotherapy. Our objective was to compare the efficacy of these two compression modalities combined with cryotherapy in relieving postoperative pain and restoring range of knee motion after ligament reconstruction surgery. When combined with cryotherapy, a dynamic and intermittent compression is associated with decreased analgesic drug requirements, less postoperative pain, and better range of knee motion compared to static compression. We conducted a case-control study of consecutive patients who underwent anterior cruciate ligament reconstruction at a single institution over a 3-month period. Both groups received the same analgesic drug protocol. One group was managed with cryotherapy and dynamic intermittent compression (Game Ready(®)) and the other with cryotherapy and static compression (IceBand(®)). Of 39 patients, 20 received dynamic and 19 static compression. In the post-anaesthesia recovery unit, the mean visual analogue scale (VAS) pain score was 2.4 (range, 0-6) with dynamic compression and 2.7 (0-7) with static compression (P=0.3); corresponding values were 1.85 (0-9) vs. 3 (0-8) (P=0.16) after 6 hours and 0.6 (0-3) vs. 1.14 (0-3) (P=0.12) at discharge. The cumulative mean tramadol dose per patient was 57.5mg (0-200mg) with dynamic compression and 128.6 mg (0-250 mg) with static compression (P=0.023); corresponding values for morphine were 0mg vs. 1.14 mg (0-8 mg) (P<0.05). Mean range of knee flexion at discharge was 90.5° (80°-100°) with dynamic compression and 84.5° (75°-90°) with static compression (P=0.0015). Dynamic intermittent compression combined with cryotherapy decreases analgesic drug requirements after ACL reconstruction and improves the postoperative recovery of range of knee motion. Level III, case-control study. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
The use of ZFP lossy floating point data compression in tornado-resolving thunderstorm simulations
NASA Astrophysics Data System (ADS)
Orf, L.
2017-12-01
In the field of atmospheric science, numerical models are used to produce forecasts of weather and climate and serve as virtual laboratories for scientists studying atmospheric phenomena. In both operational and research arenas, atmospheric simulations exploiting modern supercomputing hardware can produce a tremendous amount of data. During model execution, the transfer of floating point data from memory to the file system is often a significant bottleneck where I/O can dominate wallclock time. One way to reduce the I/O footprint is to compress the floating point data, which reduces amount of data saved to the file system. In this presentation we introduce LOFS, a file system developed specifically for use in three-dimensional numerical weather models that are run on massively parallel supercomputers. LOFS utilizes the core (in-memory buffered) HDF5 driver and includes compression options including ZFP, a lossy floating point data compression algorithm. ZFP offers several mechanisms for specifying the amount of lossy compression to be applied to floating point data, including the ability to specify the maximum absolute error allowed in each compressed 3D array. We explore different maximum error tolerances in a tornado-resolving supercell thunderstorm simulation for model variables including cloud and precipitation, temperature, wind velocity and vorticity magnitude. We find that average compression ratios exceeding 20:1 in scientifically interesting regions of the simulation domain produce visually identical results to uncompressed data in visualizations and plots. Since LOFS splits the model domain across many files, compression ratios for a given error tolerance can be compared across different locations within the model domain. We find that regions of high spatial variability (which tend to be where scientifically interesting things are occurring) show the lowest compression ratios, whereas regions of the domain with little spatial variability compress extremely well. We observe that the overhead for compressing data with ZFP is low, and that compressing data in memory reduces the amount of memory overhead needed to store the virtual files before they are flushed to disk.
MicroRNA-134-5p promotes high glucose-induced podocyte apoptosis by targeting bcl-2
Qian, Xiaoxiao; Tan, Juan; Liu, Ling; Chen, Sheng; You, Na; Yong, Huijuan; Pan, Minglin; You, Qiang; Ding, Dafa; Lu, Yibing
2018-01-01
Podocyte apoptosis is a typical early feature of diabetic nephropathy (DN), with loss of nephrin integrity contributing to increased proteinuria in patients with DN. Emerging evidence shows that microRNAs (miRNAs) play vital roles in the pathogenesis of DN. Thus, we aimed to further elucidate the role of miRNAs in podocyte apoptosis in DN. We used db/db and db/m mice maintained under a continuous feeding regime for 12 weeks. Using microarray analysis, we found several miRNAs potentially related to podocyte apoptosis. In addition, we cultured a conditionally immortalized human podocyte cell line in 30 mM D-glucose and found that miR-134-5p was upregulated in both db/db mice and high-glucose (HG)-treated podocytes. Upregulation of miR-134-5p was accompanied by podocyte apoptosis and downregulation of nephrin. Inhibition of miR-134-5p produced the opposite effect. Dual-luciferase reporter assays showed that miR-134-5p directly targeted the 3’-untranslated region of the B-cell lymphoma-2 gene (BCL2), and further study confirmed an increase in bcl-2 protein level in HG-treated podocytes transfected with anti-miR-134-5p. Knockdown of BCL2 impeded the antiapoptotic effect of anti-miR-134-5p. Finally, we found that miR-134-5p might regulate apoptosis in db/db mice and podocytes by targeting BCL2. Taken together, our findings suggest that miR-134-5p promotes podocyte apoptosis under HG conditions by targeting BCL2. Our study provides a meaningful approach to interpret the mechanisms of action of miRNAs involved in DN. PMID:29636888
Qi, Lu; Kang, Kihwa; Zhang, Cuilin; van Dam, Rob M; Kraft, Peter; Hunter, David; Lee, Chih-Hao; Hu, Frank B
2008-11-01
To examine the longitudinal association of fat mass-and obesity-associated (FTO) variant with obesity, circulating adipokine levels, and FTO expression in various materials from human and mouse. We genotyped rs9939609 in 2,287 men and 3,520 women from two prospective cohorts. Plasma adiponectin and leptin were measured in a subset of diabetic men (n = 854) and women (n = 987). Expression of FTO was tested in adipocytes from db/db mice and mouse macrophages. We observed a trend toward decreasing associations between rs9939609 and BMI at older age (>or=65 years) in men, whereas the associations were constant across different age groups in women. In addition, the single nucleotide polymorphism (SNP) rs9939609 was associated with lower plasma adiponectin (log[e]--means, 1.82 +/- 0.04, 1.73 +/- 0.03, and 1.68 +/- 0.05 for TT, TA, and AA genotypes, respectively; P for trend = 0.02) and leptin (log[e]--means, 3.56 +/- 0.04, 3.63 +/- 0.04, and 3.70 +/- 0.06; P for trend = 0.06) in diabetic women. Adjustment for BMI attenuated the associations. FTO gene was universally expressed in human and mice tissues, including adipocytes. In an ancillary study of adipocytes from db/db mice, FTO expression was approximately 50% lower than in those from wild-type mice. The association between FTO SNP rs9939609 and obesity risk may decline at older age. The variant affects circulating adiponectin and leptin levels through the changes in BMI. In addition, the expression of FTO gene was reduced in adipocytes from db/db mice.
Giglio, Vincenzo; Puddu, Paolo Emilio; Holland, Mark R; Camastra, Giovanni; Ansalone, Gerardo; Ricci, Enzo; Mela, Julia; Sciarra, Federico; Di Gennaro, Marco
2014-12-01
The aims of the study were, first, to assess whether myocardial ultrasound tissue characterization (UTC) in Becker muscular dystrophy (BMD) can be used to differentiate between patients with deletions and those without deletions; and second, to determine whether UTC is helpful in diagnosing the evolution of left ventricular dysfunction, a precursor of dilated cardiomyopathy. Both cyclic variation of integrated backscatter and calibrated integrated backscatter (cIBS) were assessed in 87 patients with BMD and 70 controls. The average follow-up in BMD patients was 48 ± 12 mo. UTC analysis was repeated only in a subgroup of 40 BMD patients randomly selected from the larger overall group (15 with and 25 without left ventricular dysfunction). Discrimination between BMD patients with and without dystrophin gene deletion was not possible on the basis of UTC data: average cvIBS was 5.2 ± 1.2 and 5.5 ± 1.4 dB, and average cIBS was 29.9 ± 4.7 and 29.6 ± 5.8, respectively, significantly different (p < 0.001) only from controls (8.6 ± 0.5 and 24.6 ± 1.2 dB). In patients developing left ventricular dysfunction during follow-up, cIBS increased to 31.3 ± 5.4 dB, but not significantly (p = 0.08). The highest cIBS values (34.6 ± 5.3 dB, p < 0.09 vs. baseline, p < 0.01 vs BMD patients without left ventricular dysfunction) were seen in the presence of severe left ventricular dysfunction. Multivariate statistics indicated that an absolute change of 6 dB in cIBS is associated with a high probability of left ventricular dysfunction. UTC analysis does not differentiate BMD patients with or without dystrophin gene deletion, but may be useful in indexing left ventricular dysfunction during follow-up. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
ZFP compression plugin (filter) for HDF5
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Mark C.
H5Z-ZFP is a compression plugin (filter) for the HDF5 library based upon the ZFP-0.5.0 compression library. It supports 4- or 8-byte integer or floating point HDF5 datasets of any dimension but partitioned in 1, 2, or 3 dimensional chunks. It supports ZFP's four fundamental modes of operation; rate, precision, accuracy or expert. It is a lossy compression plugin.
Relationship among visual field, blood flow, and neural structure measurements in glaucoma.
Hwang, John C; Konduru, Ranjith; Zhang, Xinbo; Tan, Ou; Francis, Brian A; Varma, Rohit; Sehi, Mitra; Greenfield, David S; Sadda, Srinivas R; Huang, David
2012-05-17
To determine the relationship among visual field, neural structural, and blood flow measurements in glaucoma. Case-control study. Forty-seven eyes of 42 patients with perimetric glaucoma were age-matched with 27 normal eyes of 27 patients. All patients underwent Doppler Fourier-domain optical coherence tomography to measure retinal blood flow and standard glaucoma evaluation with visual field testing and quantitative structural imaging. Linear regression analysis was performed to analyze the relationship among visual field, blood flow, and structure, after all variables were converted to logarithmic decibel scale. Retinal blood flow was reduced in glaucoma eyes compared to normal eyes (P < 0.001). Visual field loss was correlated with both reduced retinal blood flow and structural loss of rim area and retinal nerve fiber layer (RNFL). There was no correlation or paradoxical correlation between blood flow and structure. Multivariate regression analysis revealed that reduced blood flow and structural loss are independent predictors of visual field loss. Each dB decrease in blood flow was associated with at least 1.62 dB loss in mean deviation (P ≤ 0.001), whereas each dB decrease in rim area and RNFL was associated with 1.15 dB and 2.56 dB loss in mean deviation, respectively (P ≤ 0.03). There is a close link between reduced retinal blood flow and visual field loss in glaucoma that is largely independent of structural loss. Further studies are needed to elucidate the causes of the vascular dysfunction and potential avenues for therapeutic intervention. Blood flow measurement may be useful as an independent assessment of glaucoma severity.
Signal processing for the profoundly deaf.
Boothyroyd, A
1990-01-01
Profound deafness, defined here as a hearing loss in excess of 90 dB, is characterized by high thresholds, reduced hearing range in the intensity and frequency domains, and poor resolution in the frequency and time domains. The high thresholds call for hearing aids with unusually high gains or remote microphones that can be placed close to the signal source. The former option creates acoustic feedback problems for which digital signal processing may yet offer solutions. The latter option calls for carrier wave technology that is already available. The reduced frequency and intensity ranges would appear to call for frequency and/or amplitude compression. It might also be argued, however, that any attempts to compress the acoustic signal into the limited hearing range of the profoundly deaf will be counterproductive because of poor frequency and time resolution, especially when the signal is present in noise. In experiments with a 2-channel compression system, only 1 of 9 subjects showed an improvement of perception with the introduction of fast-release (20 ms) compression. The other 8 experienced no benefit or a slight deterioration of performance. These results support the concept of providing the profoundly deaf with simpler, rather than more complex, patterns, perhaps through the use of feature extraction hearing aids. Data from users of cochlear implants already employing feature extraction techniques also support this concept.
A comparison between temporal and subband minimum variance adaptive beamforming
NASA Astrophysics Data System (ADS)
Diamantis, Konstantinos; Voxen, Iben H.; Greenaway, Alan H.; Anderson, Tom; Jensen, Jørgen A.; Sboros, Vassilis
2014-03-01
This paper compares the performance between temporal and subband Minimum Variance (MV) beamformers for medical ultrasound imaging. Both adaptive methods provide an optimized set of apodization weights but are implemented in the time and frequency domains respectively. Their performance is evaluated with simulated synthetic aperture data obtained from Field II and is quantified by the Full-Width-Half-Maximum (FWHM), the Peak-Side-Lobe level (PSL) and the contrast level. From a point phantom, a full sequence of 128 emissions with one transducer element transmitting and all 128 elements receiving each time, provides a FWHM of 0.03 mm (0.14λ) for both implementations at a depth of 40 mm. This value is more than 20 times lower than the one achieved by conventional beamforming. The corresponding values of PSL are -58 dB and -63 dB for time and frequency domain MV beamformers, while a value no lower than -50 dB can be obtained from either Boxcar or Hanning weights. Interestingly, a single emission with central element #64 as the transmitting aperture provides results comparable to the full sequence. The values of FWHM are 0.04 mm and 0.03 mm and those of PSL are -42 dB and -46 dB for temporal and subband approaches. From a cyst phantom and for 128 emissions, the contrast level is calculated at -54 dB and -63 dB respectively at the same depth, with the initial shape of the cyst being preserved in contrast to conventional beamforming. The difference between the two adaptive beamformers is less significant in the case of a single emission, with the contrast level being estimated at -42 dB for the time domain and -43 dB for the frequency domain implementation. For the estimation of a single MV weight of a low resolution image formed by a single emission, 0.44 * 109 calculations per second are required for the temporal approach. The same numbers for the subband approach are 0.62 * 109 for the point and 1.33 * 109 for the cyst phantom. The comparison demonstrates similar resolution but slightly lower side-lobes and higher contrast for the subband approach at the expense of increased computation time.
Kawai, Yu; Weatherhead, Jeffrey R; Traube, Chani; Owens, Tonie A; Shaw, Brenda E; Fraser, Erin J; Scott, Annette M; Wojczynski, Melody R; Slaman, Kristen L; Cassidy, Patty M; Baker, Laura A; Shellhaas, Renee A; Dahmer, Mary K; Shever, Leah L; Malas, Nasuh M; Niedner, Matthew F
2017-01-01
Noise pollution in pediatric intensive care units (PICU) contributes to poor sleep and may increase risk of developing delirium. The Environmental Protection Agency (EPA) recommends <45 decibels (dB) in hospital environments. The objectives are to assess the degree of PICU noise pollution, to develop a delirium bundle targeted at reducing noise, and to assess the effect of the bundle on nocturnal noise pollution. This is a QI initiative at an academic PICU. Thirty-five sound sensors were installed in patient bed spaces, hallways, and common areas. The pediatric delirium bundle was implemented in 8 pilot patients (40 patient ICU days) while 108 non-pilot patients received usual care over a 28-day period. A total of 20,609 hourly dB readings were collected. Hourly minimum, average, and maximum dB of all occupied bed spaces demonstrated medians [interquartile range] of 48.0 [39.0-53.0], 52.8 [48.1-56.2] and 67.0 [63.5-70.5] dB, respectively. Bed spaces were louder during the day (10AM to 4PM) than at night (11PM to 5AM) (53.5 [49.0-56.8] vs. 51.3 [46.0-55.3] dB, P < 0.01). Pilot patient rooms were significantly quieter than non-pilot patient rooms at night (n=210, 45.3 [39.7-55.9]) vs. n=1841, 51.2 [46.9-54.8] dB, P < 0.01). The pilot rooms compliant with the bundle had the lowest hourly nighttime average dB (44.1 [38.5-55.5]). Substantial noise pollution exists in our PICU, and utilizing the pediatric delirium bundle led to a significant noise reduction that can be perceived as half the loudness with hourly nighttime average dB meeting the EPA standards when compliant with the bundle.
Identification of a second PAD1 in Brettanomyces bruxellensis LAMAP2480.
González, Camila; Godoy, Liliana; Ganga, Ma Angélica
2017-02-01
Volatile phenols are aromatic compounds produced by some yeasts of the genus Brettanomyces as defense against the toxicity of hydroxycinnamic acids (p-coumaric acid, ferulic acid and caffeic acid). The origin of these compounds in winemaking involves the sequential action of two enzymes: coumarate decarboxylase and vinylphenol reductase. The first one converts hydroxycinnamic acids into hydroxystyrenes, which are then reduced to ethyl derivatives by vinylphenol reductase. Volatile phenols derived from p-coumaric acid (4-vinylphenol and 4-ethylphenol) have been described as the major contributors to self-defeating aromas associated with stable, gouache, wet mouse, etc., which generates large economic losses in the wine industry. The gene responsible for the production of 4-vinylphenol from p-coumaric acid has been identified as PAD1, which encodes a phenylacrylic acid decarboxylase. PAD1 has been described for many species, among them Candida albicans, Candida dubliniensis, Debaryomyces hansenii and Pichia anomala. In Brettanomyces bruxellensis LAMAP2480, a 666 bp reading frame (DbPAD) encodes a coumarate decarboxylase. Recent studies have reported the existence of a new reading frame belonging to DbPAD called DbPAD2 of 531 bp, which could encode a protein with similar enzymatic activity to PAD1. The present study confirmed that the transformation of Saccharomyces cerevisiae strain BY4722 with reading frame DbPAD2 under the control of the B. bruxellensis ACT1 promoter, encodes an enzyme with coumarate decarboxylase activity. This work has provided deeper insight into the origin of aroma defects in wine due to contamination by Brettanomyces spp.
A joint source-channel distortion model for JPEG compressed images.
Sabir, Muhammad F; Sheikh, Hamid Rahim; Heath, Robert W; Bovik, Alan C
2006-06-01
The need for efficient joint source-channel coding (JSCC) is growing as new multimedia services are introduced in commercial wireless communication systems. An important component of practical JSCC schemes is a distortion model that can predict the quality of compressed digital multimedia such as images and videos. The usual approach in the JSCC literature for quantifying the distortion due to quantization and channel errors is to estimate it for each image using the statistics of the image for a given signal-to-noise ratio (SNR). This is not an efficient approach in the design of real-time systems because of the computational complexity. A more useful and practical approach would be to design JSCC techniques that minimize average distortion for a large set of images based on some distortion model rather than carrying out per-image optimizations. However, models for estimating average distortion due to quantization and channel bit errors in a combined fashion for a large set of images are not available for practical image or video coding standards employing entropy coding and differential coding. This paper presents a statistical model for estimating the distortion introduced in progressive JPEG compressed images due to quantization and channel bit errors in a joint manner. Statistical modeling of important compression techniques such as Huffman coding, differential pulse-coding modulation, and run-length coding are included in the model. Examples show that the distortion in terms of peak signal-to-noise ratio (PSNR) can be predicted within a 2-dB maximum error over a variety of compression ratios and bit-error rates. To illustrate the utility of the proposed model, we present an unequal power allocation scheme as a simple application of our model. Results show that it gives a PSNR gain of around 6.5 dB at low SNRs, as compared to equal power allocation.
Surface, Interface, and Bulk Properties of High Tc Superconductors
1989-06-30
Superconductors Phys. Rev. B 39, 823, (1989) Z.-X. Shen, P.A.P. Lindberg, B.O. Wells, D.B. Mitzi , I. Lindau, W.E. Spicer and A. Kapitulnik Valence Band...Lindau, W.E. Spicer, P. Soukiassian, D.B. Mitzi , C.B. Eom, A. Kapitulnik and T.H. Geballe Surface and Electronic Structure of Bi-Ca-Sr-Cu-O...P.A.P. Lindberg, D.S. Dessau, I. Lindau, W.E. Spicer, D.B. Mitzi , I. Bozvic and A. Kapitulnik Photoelectron energy loss study of the Bi 2CaSr 2Cu20 8
Wu, Jichao; Tian, Zhiliang; Sun, Yu; Lu, Cuicui; Liu, Ning; Gao, Zhaopeng; Zhang, Linxue; Dong, Shiyun; Yang, Fan; Zhong, Xin; Xu, Changqing; Lu, Fanghao; Zhang, Weihua
2017-01-01
Diabetic cardiomyopathy (DCM) is a serious complication of diabetes. Hydrogen sulphide (H2S), a newly found gaseous signalling molecule, has an important role in many regulatory functions. The purpose of this study is to investigate the effects of exogenous H2S on autophagy and its possible mechanism in DCM induced by type II diabetes (T2DCM). In this study, we found that sodium hydrosulphide (NaHS) attenuated the augment in left ventricular (LV) mass and increased LV volume, decreased reactive oxygen species (ROS) production and ameliorated H2S production in the hearts of db/db mice. NaHS facilitated autophagosome content degradation, reduced the expression of P62 (a known substrate of autophagy) and increased the expression of microtubule-associated protein 1 light chain 3 II. It also increased the expression of autophagy-related protein 7 (ATG7) and Beclin1 in db/db mouse hearts. NaHS increased the expression of Kelch-like ECH-associated protein 1 (Keap-1) and reduced the ubiquitylation level in the hearts of db/db mice. 1,4-Dithiothreitol, an inhibitor of disulphide bonds, increased the ubiquitylation level of Keap-1, suppressed the expression of Keap-1 and abolished the effects of NaHS on ubiquitin aggregate clearance and ROS production in H9C2 cells treated with high glucose and palmitate. Overall, we concluded that exogenous H2S promoted ubiquitin aggregate clearance via autophagy, which might exert its antioxidative effect in db/db mouse myocardia. Moreover, exogenous H2S increased Keap-1 expression by suppressing its ubiquitylation, which might have an important role in ubiquitin aggregate clearance via autophagy. Our findings provide new insight into the mechanisms responsible for the antioxidative effects of H2S in the context of T2DCM. PMID:28796243
Testing of visual field with virtual reality goggles in manual and visual grasp modes.
Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas
2014-01-01
Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.
NASA Astrophysics Data System (ADS)
Qin, Guoxuan; Yuan, Hao-Chih; Celler, George K.; Zhou, Weidong; Ma, Zhenqiang
2009-12-01
This paper reports the realization of flexible RF/microwave PIN diodes and switches using transferrable single-crystal Si nanomembranes (SiNM) that are monolithically integrated on low-cost, flexible plastic substrates. High frequency response is obtained through the realization of low parasitic resistance achieved with heavy ion implantation before nanomembrane release and transfer. The flexible lateral SiNM PIN diodes exhibit typical rectifying characteristics with insertion loss and isolation better than 0.9 dB and 19.6 dB, respectively, from DC to 5 GHz, as well as power handling up to 22.5 dBm without gain compression. A single-pole single-throw (SPST) flexible RF switch employing shunt-series PIN diode configuration has achieved insertion loss and isolation better than 0.6 dB and 22.9 dB, respectively, from DC to 5 GHz. Furthermore, the SPST microwave switch shows performance improvement and robustness under mechanical deformation conditions. The study demonstrates the considerable potential of using properly processed transferrable SiNM for microwave passive components. Future investigations on transferrable SiNMs will lead to eventual realization of monolithic microwave integrated systems on low-cost flexible substrates.
Montenegro, Mary L L S; Braz, Carolina A; Rosa-e-Silva, Julio C; Candido-dos-Reis, Francisco J; Nogueira, Antonio A; Poli-Neto, Omero B
2015-12-01
Chronic pelvic pain is a common condition among women, and 10 to 30 % of causes originate from the abdominal wall, and are associated with trigger points. Although little is known about their pathophysiology, variable methods have been practiced clinically. The purpose of this study was to evaluate the efficacy of local anaesthetic injections versus ischemic compression via physical therapy for pain relief of abdominal wall trigger points in women with chronic pelvic pain. We conducted a parallel group randomized trial including 30 women with chronic pelvic pain with abdominal wall trigger points. Subjects were randomly assigned to one of two intervention groups. One group received an injection of 2 mL 0.5 % lidocaine without a vasoconstrictor into a trigger point. In the other group, ischemic compression via physical therapy was administered at the trigger points three times, with each session lasting for 60 s, and a rest period of 30 s between applications. Both treatments were administered during one weekly session for four weeks. Our primary outcomes were satisfactory clinical response rates and percentages of pain relief. Our secondary outcomes are pain threshold and tolerance at the trigger points. All subjects were evaluated at baseline and 1, 4, and 12 weeks after the interventions. The study was conducted at a tertiary hospital that was associated with a university providing assistance predominantly to working class women who were treated by the public health system. Clinical response rates and pain relief were significantly better at 1, 4, and 12 weeks for those receiving local anaesthetic injections than ischemic compression via physical therapy. The pain relief of women treated with local anaesthetic injections progressively improved at 1, 4, and 12 weeks after intervention. In contrast, women treated with ischemic compression did not show considerable changes in pain relief after intervention. In the local anaesthetic injection group, pain threshold and tolerance improved with time in the absence of significant differences between groups. Lidocaine injection seems to be better for reducing the severity of chronic pelvic pain secondary to abdominal wall trigger points compared to ischemic compression via physical therapy. ClinicalTrials.gov NCT00628355. Date of registration: February 25, 2008.
Zhao, Ruozhi; Le, Khuong; Moghadasian, Mohammed H; Shen, Garry X
2013-08-01
Cardiovascular disease is the predominant cause of death in diabetic patients. Fibroblasts are one of the major types of cells in the heart or vascular wall. Increased levels of glycated low-density lipoprotein (glyLDL) were detected in diabetic patients. Previous studies in our group demonstrated that oxidized LDL increased the amounts of NADPH oxidase (NOX), plasminogen activator inhibitor-1 (PAI-1), and heat shock factor-1 (HSF1) in fibroblasts. This study examined the expression of NOX, PAI-1, and HSF1 in glyLDL-treated wild-type or HSF1-deficient mouse embryo fibroblasts (MEFs) and in leptin receptor-knockout (db/db) diabetic mice. Treatment with physiologically relevant levels of glyLDL increased superoxide and H2O2 release and the levels of NOX4 and p22phox (an essential component of multiple NOX complexes) in wild-type or HSF1-deficient MEFs. The levels of HSF1 and PAI-1 were increased by glyLDL in wild-type MEFs, but not in HSF1-deficient MEFs. Diphenyleneiodonium (a nonspecific NOX inhibitor) or small interfering RNA for p22phox prevented glyLDL-induced increases in the levels of NOX4, HSF1, or PAI-1 in MEFs. The amounts of NOX4, HSF1, and PAI-1 were elevated in hearts of db/db diabetic mice compared to wild-type mice. The results suggest that glyLDL increased the abundance of NOX4 or p22phox via an HSF1-independent pathway, but that of PAI-1 via an HSF1-dependent manner. NOX4 plays a crucial role in glyLDL-induced expression of HSF1 and PAI-1 in mouse fibroblasts. Increased expression of NOX4, HSF1, and PAI-1 was detected in cardiovascular tissue of diabetic mice. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Barrie, A. C.; Smith, S. E.; Dorelli, J. C.; Gershman, D. J.; Yeh, P.; Schiff, C.; Avanov, L. A.
2017-01-01
Data compression has been a staple of imaging instruments for years. Recently, plasma measurements have utilized compression with relatively low compression ratios. The Fast Plasma Investigation (FPI) on board the Magnetospheric Multiscale (MMS) mission generates data roughly 100 times faster than previous plasma instruments, requiring a higher compression ratio to fit within the telemetry allocation. This study investigates the performance of a space-based compression standard employing a Discrete Wavelet Transform and a Bit Plane Encoder (DWT/BPE) in compressing FPI plasma count data. Data from the first 6 months of FPI operation are analyzed to explore the error modes evident in the data and how to adapt to them. While approximately half of the Dual Electron Spectrometer (DES) maps had some level of loss, it was found that there is little effect on the plasma moments and that errors present in individual sky maps are typically minor. The majority of Dual Ion Spectrometer burst sky maps compressed in a lossless fashion, with no error introduced during compression. Because of induced compression error, the size limit for DES burst images has been increased for Phase 1B. Additionally, it was found that the floating point compression mode yielded better results when images have significant compression error, leading to floating point mode being used for the fast survey mode of operation for Phase 1B. Despite the suggested tweaks, it was found that wavelet-based compression, and a DWT/BPE algorithm in particular, is highly suitable to data compression for plasma measurement instruments and can be recommended for future missions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pieper, Claus Christian, E-mail: claus.christian.pieper@ukb.uni-bonn.de; Thomas, Daniel, E-mail: daniel.thomas@ukb.uni-bonn.de; Nadal, Jennifer, E-mail: jennifer.nadal@ukb.uni-bonn.de
PurposeTo intra-individually compare discomfort levels and patient satisfaction after arterial access closure using the ExoSeal{sup ®} vascular closure device (VCD) and manual compression (MC) in a prospective study design.MethodsPatients undergoing two planned interventions from 07/2013 to 09/2014 could participate in the study. Access closure was performed with an ExoSeal{sup ®}-VCD in one and MC in the other intervention. Patients were clinically and sonographically examined and were given questionnaires 1 day after intervention [groin- and back-pain during bedrest (100-point visual analog scale; 0: no pain); comfortability of bedrest (10-point Likert scale, 1: comfortable), satisfaction with closure (10-point Likert scale, 1: very satisfied)].more » Results were analyzed in a cross-over design.Results48 patients (29 male, median age 62.5 (32–88) years) were included. An ExoSeal{sup ®}-VCD was used first in 25 cases. As four of these subsequently refused MC as second intervention, data from 44 patients could be analyzed. All closures were technically successful (successful device deployment) without major complications. Groin- and back-pain after VCD-use/MC was 0 (0–15) vs. 10 (0–80) and 0 (0–75) vs. 25 (0–90), respectively (p < 0.0001). Bedrest after VCD-use was more comfortable than after MC [1 (range 1–7) vs. 6 (2–10); p < 0.0001]. Satisfaction with the closure procedure and with the intervention in general was higher after VCD-use compared to MC [1 (1–3) vs. 5 (2–10) and 1 (1–2) vs. 2 (1–4), respectively; p < 0.0001].ConclusionIntra-individual comparison showed pain levels and discomfort to be significantly lower after ExoSeal{sup ®} use compared to MC. VCD closure was associated with higher satisfaction both with the closure itself and with the intervention in general.« less
1993-06-01
s )) = Op (C(s), db(s))" (26) Equation (27) defines OP. Brt(JxBR’T()-,BR as the complement of Op,. Op,(C(s), db(s)) = 0p,(C(s), db(s))’" (27) The...9.5 tf=13.0 t= 11.0 tf= 12.8 128 words tr-13.5 tf=16.9 t,=14.3 t(=17.3 t,=16.5 tf=22.0 Op,,(C(s), db( s )), Op .<(C(s), db( s )), Op ,(C(s), db( s )), Op >(C...OP.(C(s), db( s )), Op •(C(s), db( s )), Op <(C(s), db( s )), Op >(C(s), db( s )), Op .(C(s), db( s
Gap detection threshold in the rat before and after auditory cortex ablation.
Syka, J; Rybalko, N; Mazelová, J; Druga, R
2002-10-01
Gap detection threshold (GDT) was measured in adult female pigmented rats (strain Long-Evans) by an operant conditioning technique with food reinforcement, before and after bilateral ablation of the auditory cortex. GDT was dependent on the frequency spectrum and intensity of the continuously present noise in which the gaps were embedded. The mean values of GDT for gaps embedded in white noise or low-frequency noise (upper cutoff frequency 3 kHz) at 70 dB sound pressure level (SPL) were 1.57+/-0.07 ms and 2.9+/-0.34 ms, respectively. Decreasing noise intensity from 80 dB SPL to 20 dB SPL produced a significant increase in GDT. The increase in GDT was relatively small in the range of 80-50 dB SPL for white noise and in the range of 80-60 dB for low-frequency noise. The minimal intensity level of the noise that enabled GDT measurement was 20 dB SPL for white noise and 30 dB SPL for low-frequency noise. Mean GDT values at these intensities were 10.6+/-3.9 ms and 31.3+/-4.2 ms, respectively. Bilateral ablation of the primary auditory cortex (complete destruction of the Te1 and partial destruction of the Te2 and Te3 areas) resulted in an increase in GDT values. The fifth day after surgery, the rats were able to detect gaps in the noise. The values of GDT observed at this time were 4.2+/-1.1 ms for white noise and 7.4+/-3.1 ms for low-frequency noise at 70 dB SPL. During the first month after cortical ablation, recovery of GDT was observed. However, 1 month after cortical ablation GDT still remained slightly higher than in controls (1.8+/-0.18 for white noise, 3.22+/-0.15 for low-frequency noise, P<0.05). A decrease in GDT values during the subsequent months was not observed.
Two-thumb technique is superior to two-finger technique during lone rescuer infant manikin CPR.
Udassi, Sharda; Udassi, Jai P; Lamb, Melissa A; Theriaque, Douglas W; Shuster, Jonathan J; Zaritsky, Arno L; Haque, Ikram U
2010-06-01
Infant CPR guidelines recommend two-finger chest compression with a lone rescuer and two-thumb with two rescuers. Two-thumb provides better chest compression but is perceived to be associated with increased ventilation hands-off time. We hypothesized that lone rescuer two-thumb CPR is associated with increased ventilation cycle time, decreased ventilation quality and fewer chest compressions compared to two-finger CPR in an infant manikin model. Crossover observational study randomizing 34 healthcare providers to perform 2 min CPR at a compression rate of 100 min(-1) using a 30:2 compression:ventilation ratio comparing two-thumb vs. two-finger techniques. A Laerdal Baby ALS Trainer manikin was modified to digitally record compression rate, compression depth and compression pressure and ventilation cycle time (two mouth-to-mouth breaths). Manikin chest rise with breaths was video recorded and later reviewed by two blinded CPR instructors for percent effective breaths. Data (mean+/-SD) were analyzed using a two-tailed paired t-test. Significance was defined qualitatively as p< or =0.05. Mean % effective breaths were 90+/-18.6% in two-thumb and 88.9+/-21.1% in two-finger, p=0.65. Mean time (s) to deliver two mouth-to-mouth breaths was 7.6+/-1.6 in two-thumb and 7.0+/-1.5 in two-finger, p<0.0001. Mean delivered compressions per minute were 87+/-11 in two-thumb and 92+/-12 in two-finger, p=0.0005. Two-thumb resulted in significantly higher compression depth and compression pressure compared to the two-finger technique. Healthcare providers required 0.6s longer time to deliver two breaths during two-thumb lone rescuer infant CPR, but there was no significant difference in percent effective breaths delivered between the two techniques. Two-thumb CPR had 4 fewer delivered compressions per minute, which may be offset by far more effective compression depth and compression pressure compared to two-finger technique. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
The wnt/β-catenin signaling pathway participates in rhein ameliorating kidney injury in DN mice.
Duan, Suyan; Wu, Yingyi; Zhao, Chuanyan; Chen, Mingyu; Yuan, Yanggang; Xing, Changying; Zhang, Bo
2016-01-01
The present study aimed to investigate the relationship between wnt/β-catenin signaling pathway and kidney impairment in diabetic nephropathy (DN) mice as well as the renoprotective effect of rhein (RH). Mice were randomly divided into four groups (n = 6): db/db mice treated with RH (DN + RH), db/db mice (DN), db/m mice treated with RH (NC + RH) and db/m mice (NC). RH-treated groups were administered orally at a daily dose 120 mg/kg. Mice were sacrificed after 12 weeks of treatments. In our study, increased albuminuria, together with weight gain and hyperglycemia was observed in the beginning of the study and continued to increase throughout the length of the study (12 weeks). Histopathologic changes were observed in the DN group. Expectedly, mice receiving the treatment with RH were protected from this injury. Meanwhile, the expression of nephrin, a podocyte-specific marker, was significantly reduced while wnt1, p-GSK-3β/tGSK-3β, p-β-catenin/tβ-catenin were higher in the DN group mice when analyzed by immunofluorescence and Western blotting. RH reversed these above changes. wnt/β-catenin signaling pathway participates in RH ameliorating kidney injury in DN mice. The manipulation of RH might act as a promising therapeutic intervention for DN.
Gonzalez-Hernandez, M; de la Rosa, M Gonzalez; de la Vega, R Rodriguez; Hernandez-Vidal, A
2007-01-01
Analyze the stability and accuracy of 3 perimetric techniques. A total of 104 stable eyes (65 subjects) with ocular hypertension and early glaucoma [group G, mean defect = 1.08 dB, SD = 2.0, in standard TOP automatic perimetry (SAP)] were examined 5 times during 18 months using: (a) SAP; (b) Pulsar temporal modulation perimetry (T30W), and (c) frequency-doubling technology (FDT N30). Ninety eyes from 90 normal controls were compared with the first set of examinations of group G. The learning effect was minimal in the 3 techniques but higher in Pulsar (1.0 src, p < 0.05) than in SAP and FDT (0.4 dB). Long-term fluctuation (F) was significantly higher in FDT (3.1 dB, SD = 1.4, p < 0.0001) than in SAP (2.3 dB, SD = 1.1) and in Pulsar (1.9 src, SD = 0.7). Pulsar and FDT reduce F when increasing the number of examinations. F seems equivalent in SAP and FDT and lower in Pulsar, considering small-scale differences of the 3 perimeters. A slight learning effect would be expected on FDT and SAP in patients with previous experience with SAP. The stability and sensitivity of Pulsar is greater than on the other 2 systems. For early diagnosis of glaucoma it is essential to prove the reproducibility and coincidence of perimetric results. (c) 2007 S. Karger AG, Basel.
Using Bitmap Indexing Technology for Combined Numerical and TextQueries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stockinger, Kurt; Cieslewicz, John; Wu, Kesheng
2006-10-16
In this paper, we describe a strategy of using compressedbitmap indices to speed up queries on both numerical data and textdocuments. By using an efficient compression algorithm, these compressedbitmap indices are compact even for indices with millions of distinctterms. Moreover, bitmap indices can be used very efficiently to answerBoolean queries over text documents involving multiple query terms.Existing inverted indices for text searches are usually inefficient forcorpora with a very large number of terms as well as for queriesinvolving a large number of hits. We demonstrate that our compressedbitmap index technology overcomes both of those short-comings. In aperformance comparison against amore » commonly used database system, ourindices answer queries 30 times faster on average. To provide full SQLsupport, we integrated our indexing software, called FastBit, withMonetDB. The integrated system MonetDB/FastBit provides not onlyefficient searches on a single table as FastBit does, but also answersjoin queries efficiently. Furthermore, MonetDB/FastBit also provides avery efficient retrieval mechanism of result records.« less
Milles, Jeffrey L; Nuelle, Clayton W; Pfeiffer, Ferris; Stannard, James P; Smith, Patrick; Kfuri, Mauricio; Cook, James L
2017-05-01
Controversy exists regarding double-bundle (DB) versus single-bundle (SB) posterior cruciate ligament (PCL) reconstruction, with differences in multiple variables affecting biomechanical and clinical results. Our objective was to compare immediate postimplantation biomechanics of SB versus DB reconstructions to determine the relative importance of restoring both PCL bundles versus total graft volume. Twenty knees were randomly assigned to five techniques ( n = 4 knees/technique), performed by three surgeons experienced in their technique(s), three SB techniques ( n = 12; all-inside arthroscopic inlay, all-inside suspensory fixation, and arthroscopic-assisted open onlay), and two DB techniques ( n = 8; arthroscopic-assisted open inlay and all-inside suspensory fixation). Each knee was tested in three conditions: PCL-intact, PCL-deficient, and post-PCL reconstruction. Testing consisted of a posterior-directed force at four knee flexion angles, 10, 30, 60, and 90 degrees, to measure load to 5 mm of posterior displacement, maximum displacement (at 100 N load), and stiffness. Data for each knee were normalized, combined into two groups (SB and DB), and then compared using one-way analysis of variance. Graft volumes were calculated and analyzed to determine if differences significantly influenced the biomechanical results. Intact knees were stiffer than both groups at most angles ( p < 0.02; p < 0.05). DB was stiffer than SB at all angles except 30 degrees ( p < 0.05). Intact knees had less laxity than SB ( p < 0.03) and DB ( p < 0.05) at 60 and 90 degrees. DB had less laxity than SB at all angles except 60 degrees ( p < 0.05). Intact knees required more load than SB at 30, 60, and 90 degrees ( p < 0.01) and more than DB at 60 and 90 degrees ( p < 0.05). DB required more load than SB at 30, 60, and 90 degrees ( p < 0.01). Graft volumes did not have strong correlations ( r = 0.13-0.37) to any measurements. Neither group of PCL reconstruction techniques was able to replicate native PCL biomechanics. DB reconstructions were biomechanically superior to SB reconstructions; they may be preferred for clinical use when immediate post-reconstruction graft strength and stability are critical. These results were not strongly influenced by graft size differences, further supporting the PCL codominance theory. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Uchtenhagen, Hannes; Abualrous, Esam T; Stahl, Evi; Allerbring, Eva B; Sluijter, Marjolein; Zacharias, Martin; Sandalova, Tatyana; van Hall, Thorbald; Springer, Sebastian; Nygren, Per-Åke; Achour, Adnane
2013-11-01
The immunogenicity of H-2D(b) (D(b)) restricted epitopes can be significantly increased by substituting peptide position 3 to a proline (p3P). The p3P modification enhances MHC stability without altering the conformation of the modified epitope allowing for T-cell cross-reactivity with the native peptide. The present study reveals how specific interactions between p3P and the highly conserved MHC heavy chain residue Y159 increase the stability of D(b) in complex with an optimized version of the melanoma-associated epitope gp10025-33 . Furthermore, the p3P modification directly increased the affinity of the D(b)/gp10025-33 -specific T-cell receptor (TCR) pMel. Surprisingly, the enhanced TCR binding was independent from the observed increased stability of the optimized D(b)/gp10025-33 complex and from the interactions formed between p3P and Y159, indicating a direct effect of the p3P modification on TCR recognition. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Liu, Yuan; Wang, Renxin; Zhang, Guojun; Du, Jin; Zhao, Long; Xue, Chenyang; Zhang, Wendong; Liu, Jun
2015-07-01
This paper presents methods of promoting the sensitivity of Microelectromechanical Systems (MEMS) vector hydrophone by increasing the sensing area of cilium and perfect insulative Parylene membrane. First, a low-density sphere is integrated with the cilium to compose a "lollipop shape," which can considerably increase the sensing area. A mathematic model on the sensitivity of the "lollipop-shaped" MEMS vector hydrophone is presented, and the influences of different structural parameters on the sensitivity are analyzed via simulation. Second, the MEMS vector hydrophone is encapsulated through the conformal deposition of insulative Parylene membrane, which enables underwater acoustic monitoring without any typed sound-transparent encapsulation. Finally, the characterization results demonstrate that the sensitivity reaches up to -183 dB (500 Hz 0dB at 1 V/ μPa ), which is increased by more than 10 dB, comparing with the previous cilium-shaped MEMS vector hydrophone. Besides, the frequency response takes on a sensitivity increment of 6 dB per octave. The working frequency band is 20-500 Hz and the concave point depth of 8-shaped directivity is beyond 30 dB, indicating that the hydrophone is promising in underwater acoustic application.
Yoon, Jeong Hee; Yu, Mi Hye; Chang, Won; Park, Jin-Young; Nickel, Marcel Dominik; Son, Yohan; Kiefer, Berthold; Lee, Jeong Min
2017-10-01
The purpose of the study was to investigate the clinical feasibility of free-breathing dynamic T1-weighted imaging (T1WI) using Cartesian sampling, compressed sensing, and iterative reconstruction in gadoxetic acid-enhanced liver magnetic resonance imaging (MRI). This retrospective study was approved by our institutional review board, and the requirement for informed consent was waived. A total of 51 patients at high risk of breath-holding failure underwent dynamic T1WI in a free-breathing manner using volumetric interpolated breath-hold (BH) examination with compressed sensing reconstruction (CS-VIBE) and hard gating. Timing, motion artifacts, and image quality were evaluated by 4 radiologists on a 4-point scale. For patients with low image quality scores (<3) on the late arterial phase, respiratory motion-resolved (extradimension [XD]) reconstruction was additionally performed and reviewed in the same manner. In addition, in 68.6% (35/51) patients who had previously undergone liver MRI, image quality and motion artifacts on dynamic phases using CS-VIBE were compared with previous BH-T1WIs. In all patients, adequate arterial-phase timing was obtained at least once. Overall image quality of free-breathing T1WI was 3.30 ± 0.59 on precontrast and 2.68 ± 0.70, 2.93 ± 0.65, and 3.30 ± 0.49 on early arterial, late arterial, and portal venous phases, respectively. In 13 patients with lower than average image quality (<3) on the late arterial phase, motion-resolved reconstructed T1WI (XD-reconstructed CS-VIBE) significantly reduced motion artifacts (P < 0.002-0.021) and improved image quality (P < 0.0001-0.002). In comparison with previous BH-T1WI, CS-VIBE with hard gating or XD reconstruction showed less motion artifacts and better image quality on precontrast, arterial, and portal venous phases (P < 0.0001-0.013). Volumetric interpolated breath-hold examination with compressed sensing has the potential to provide consistent, motion-corrected free-breathing dynamic T1WI for liver MRI in patients at high risk of breath-holding failure.
Football Equipment Removal Improves Chest Compression and Ventilation Efficacy.
Mihalik, Jason P; Lynall, Robert C; Fraser, Melissa A; Decoster, Laura C; De Maio, Valerie J; Patel, Amar P; Swartz, Erik E
2016-01-01
Airway access recommendations in potential catastrophic spine injury scenarios advocate for facemask removal, while keeping the helmet and shoulder pads in place for ensuing emergency transport. The anecdotal evidence to support these recommendations assumes that maintaining the helmet and shoulder pads assists inline cervical stabilization and that facial access guarantees adequate airway access. Our objective was to determine the effect of football equipment interference on performing chest compressions and delivering adequate ventilations on patient simulators. We hypothesized that conditions with more football equipment would decrease chest compression and ventilation efficacy. Thirty-two certified athletic trainers were block randomized to participate in six different compression conditions and six different ventilation conditions using human patient simulators. Data for chest compression (mean compression depth, compression rate, percentage of correctly released compressions, and percentage of adequate compressions) and ventilation (total ventilations, mean ventilation volume, and percentage of ventilations delivering adequate volume) conditions were analyzed across all conditions. The fully equipped athlete resulted in the lowest mean compression depth (F5,154 = 22.82; P < 0.001; Effect Size = 0.98) and delivery of adequate compressions (F5,154 = 15.06; P < 0.001; Effect Size = 1.09) compared to all other conditions. Bag-valve mask conditions resulted in delivery of significantly higher mean ventilation volumes compared to all 1- or 2-person pocketmask conditions (F5,150 = 40.05; P < 0.001; Effect Size = 1.47). Two-responder ventilation scenarios resulted in delivery of a greater number of total ventilations (F5,153 = 3.99; P = 0.002; Effect Size = 0.26) and percentage of adequate ventilations (F5,150 = 5.44; P < 0.001; Effect Size = 0.89) compared to one-responder scenarios. Non-chinstrap conditions permitted greater ventilation volumes (F3,28 = 35.17; P < 0.001; Effect Size = 1.78) and a greater percentage of adequate volume (F3,28 = 4.85; P = 0.008; Effect Size = 1.12) compared to conditions with the chinstrap buckled or with the chinstrap in place but not buckled. Chest compression and ventilation delivery are compromised in equipment-intense conditions when compared to conditions whereby equipment was mostly or entirely removed. Emergency medical personnel should remove the helmet and shoulder pads from all football athletes who require cardiopulmonary resuscitation, while maintaining appropriate cervical spine stabilization when injury is suspected. Further research is needed to confirm our findings supporting full equipment removal for chest compression and ventilation delivery.
Souday, Vincent; Koning, Nick J; Perez, Bruno; Grelon, Fabien; Mercat, Alain; Boer, Christa; Seegers, Valérie; Radermacher, Peter; Asfar, Pierre
2016-01-01
To test the hypothesis whether enriched air nitrox (EAN) breathing during simulated diving reduces decompression stress when compared to compressed air breathing as assessed by intravascular bubble formation after decompression. Human volunteers underwent a first simulated dive breathing compressed air to include subjects prone to post-decompression venous gas bubbling. Twelve subjects prone to bubbling underwent a double-blind, randomized, cross-over trial including one simulated dive breathing compressed air, and one dive breathing EAN (36% O2) in a hyperbaric chamber, with identical diving profiles (28 msw for 55 minutes). Intravascular bubble formation was assessed after decompression using pulmonary artery pulsed Doppler. Twelve subjects showing high bubble production were included for the cross-over trial, and all completed the experimental protocol. In the randomized protocol, EAN significantly reduced the bubble score at all time points (cumulative bubble scores: 1 [0-3.5] vs. 8 [4.5-10]; P < 0.001). Three decompression incidents, all presenting as cutaneous itching, occurred in the air versus zero in the EAN group (P = 0.217). Weak correlations were observed between bubble scores and age or body mass index, respectively. EAN breathing markedly reduces venous gas bubble emboli after decompression in volunteers selected for susceptibility for intravascular bubble formation. When using similar diving profiles and avoiding oxygen toxicity limits, EAN increases safety of diving as compared to compressed air breathing. ISRCTN 31681480.
Point-Cloud Compression for Vehicle-Based Mobile Mapping Systems Using Portable Network Graphics
NASA Astrophysics Data System (ADS)
Kohira, K.; Masuda, H.
2017-09-01
A mobile mapping system is effective for capturing dense point-clouds of roads and roadside objects Point-clouds of urban areas, residential areas, and arterial roads are useful for maintenance of infrastructure, map creation, and automatic driving. However, the data size of point-clouds measured in large areas is enormously large. A large storage capacity is required to store such point-clouds, and heavy loads will be taken on network if point-clouds are transferred through the network. Therefore, it is desirable to reduce data sizes of point-clouds without deterioration of quality. In this research, we propose a novel point-cloud compression method for vehicle-based mobile mapping systems. In our compression method, point-clouds are mapped onto 2D pixels using GPS time and the parameters of the laser scanner. Then, the images are encoded in the Portable Networking Graphics (PNG) format and compressed using the PNG algorithm. In our experiments, our method could efficiently compress point-clouds without deteriorating the quality.
The influence of constitutional isomerism and change on molecular recognition processes.
Williams, Avril R; Northrop, Brian H; Houk, Kendall N; Stoddart, J Fraser; Williams, David J
2004-10-25
Three constitutionally isomeric bis(naphthylmethyl)ammonium ions, in which the two naphthyl groups are substituted 1) both at their 1-positions, 2) one at its 1-position and the other at its 2-position, and 3) both at their 2-positions, have been investigated separately in solution for their propensities to undergo spontaneous self-assembly with three different [24]crown-8 derivatives, namely, pyrido[24]crown-8 (P24C8), dipyrido[24]crown-8 (DP24C8) and dibenzo[24]crown-8 (DB24C8), in turn to form [2]pseudorotaxanes. The strengths of the 1:1 complexes depend on the composition of the secondary dialkylammonium ions and on the nature of the crown ether hosts; generally, as far as the guest cation is concerned, the 1/1- and 2/2-isomers form stronger complexes, as indicated by stability constant measurements, than the 1/2-isomer and, as far as the crown ethers are concerned, the more flexible P24C8 is a much more efficient host than either DP24C8 or DB24C8. The rates of formation of the [2]pseudorotaxanes are fast (i.e., taking no more than a few minutes) in solution with the exception of one case, that is, in which the crown ether host is DB24C8 and the guest cation is the 1/1-isomer, when it can take upwards of one month for the complexation-decomplexation equilibrium to be established at room temperature. In all cases, the equilibrium between complexed and uncomplexed species is slow on the NMR timescale, allowing the determination of stability constants to be made readily using the single-point method. X-ray crystallography and molecular modeling have been used to gain insight into ground and transition state interactions, respectively, in some of the [2]pseudorotaxanes. The relative stabilities of the three [2]pseudorotaxanes formed by each guest cation in the presence of the three crown ether hosts were also evaluated in solution by competition experiments that were monitored by (1)H NMR spectroscopy. By and large the results of the competition experiments could be predicted on the basis of the derived stability constants for the individual [2]pseudorotaxanes.
NASA Astrophysics Data System (ADS)
Li, Benye; Jiang, Lan; Wang, Sumei; Tsai, Hai-Lung; Xiao, Hai
2011-11-01
An improved point-by-point inscription method is proposed to fabricate long period fiber gratings (LPFGs) by using a laser operating at 800 nm with 35 fs duration pulses. The sensitivity to misalignment between the core and the focus is reduced by scanning a rectangular part on the fiber. LPFGs with an attenuation depth of 20 dB are achieved within the wavelength range of 1465-1575 nm. Characterization of the temperature sensitivity and thermal stability of the LPFGs is presented. A 5.6 nm wavelength shift and a 1.2 dB decrease in the attenuation peak are observed following heat treatment at 600 °C for 4 h. The fabricated LPFGs are used as refractive index sensors. The effect of heat treatment on the response of the LPFGs to refractive index changes is also studied.
Assessment of the sedative effects of buprenorphine administered with 10 μg/kg detomidine in horses.
Love, E J; Taylor, P M; Murrell, J; Whay, H R; Waterman-Pearson, A E
2011-04-09
The aim of this randomised, observer-blinded, crossover study was to compare the effects of six treatments, administered intravenously to six horses: saline and saline (S/S); detomidine and saline (D/S); detomidine and 5 µg/kg buprenorphine (D/B5); detomidine and 7.5 µg/kg buprenorphine (D/B7.5); detomidine and 10 µg/kg buprenorphine (D/B10); and detomidine and 25 µg/kg butorphanol (D/BUT). The detomidine dose was 10 µg/kg for all treatments in which it was included. Sedation was subjectively assessed and recorded on a visual analogue scale. Peak sedation, duration of sedation and the area under the curve (AUC) for sedation scores were investigated using a univariate general linear model with post-hoc Tukey tests (P<0.05). Peak sedation and duration of sedation were statistically significantly different between treatments (P<0.001). No sedation was apparent after administration of S/S. The AUC was significantly different between treatments (P=0.010), with S/S being significantly different from D/S, D/BUT, D/B5 and D/B7.5, but not D/B10 (P=0.051).
Histone methyltransferase G9a modulates hepatic insulin signaling via regulating HMGA1.
Xue, Weili; Huang, Jin; Chen, Hong; Zhang, Yu; Zhu, Xiuqin; Li, Jianshuang; Zhang, Wenquan; Yuan, Yangmian; Wang, Yan; Zheng, Ling; Huang, Kun
2018-02-01
Hepatic insulin sensitivity is critical for glucose homeostasis, and insulin resistance is a fundamental syndrome found in various metabolic disorders, including obesity and type 2 diabetes. Despite considerable studies on the mechanisms of hepatic insulin resistance, the link between epigenetic regulation and the development of insulin resistance remains elusive. Here, we reported that G9a/EHMT2, a histone methyltransferase, was markedly decreased in the liver of db/db mice and high-fat diet (HFD)-fed mice. In cultured hepatic cells, G9a knockdown resulted in downregulation of insulin receptor, p-AKT and p-GSK3β; while upon upregulation, G9a prevented the palmitic acid- or glucosamine-induced insulin resistance by preserving the normal level of insulin receptor and integrity of insulin signaling. Further mechanistic study suggested that G9a regulated the expression level of high mobility group AT-hook 1 (HMGA1), a key regulator responsible for the transcription of insulin receptor (INSR) gene. Overexpression of HMGA1 normalized the impaired insulin signaling in G9a knockdown hepatic cells. Importantly, in db/db mice, restoring the expression level of G9a not only upregulated HMGA1 level and improved the impaired hepatic insulin signaling, but also alleviated hyperglycemia and hyperinsulinemia. Together, our results revealed a novel role for G9a in modulating insulin signaling, at least in part, depending on its regulatory function on HMGA1. Copyright © 2017 Elsevier B.V. All rights reserved.
The Tripole Antenna: An Adaptive Array with Full Polarization Flexibility.
1980-12-01
The polarization ellipse 4 3 The Poincare sphere 6 4 SINR vs. Bi. 12 8d=450 , @d=450, ad=1!5, Bd=30 °, SNR=O dB 00i= 45 , INR-4O dB. 5 SINR vs. 01, 13...y and n is most easily visualized by making use of the Poincare Sphere 4 . This tech- nique represents the state of polarization by a point on a...clockwise circular polarization (a = + 450) at the upper pole. Thus, an arbitrary plane wave coming into the array may be character- ized by four
Compression of laminated composite beams with initial damage
NASA Technical Reports Server (NTRS)
Breivik, Nicole L.; Gurdal, Zafer; Griffin, O. H., Jr.
1993-01-01
The effect of isolated damage modes on the compressive strength and failure characteristics of laminated composite test specimens were evaluated experimentally and numerically. In addition to specimens without initial damage, specimens with three types of initial damage were considered: (1) specimens with short delaminations distributed evenly through the specimen thickness, (2) specimens with few long delaminations, and (3) specimens with local fiber damage in the surface plies under the three-point bend contact point. It was found that specimens with short multiple delamination experienced the greatest reduction in compression strength compared to the undamaged specimens. Single delaminations far from the specimen surface had little effect on the final compression strength, and moderate strength reduction was observed for specimens with localized surface ply damage.
Helleman, Hiske W; Dreschler, Wouter A
2015-02-01
To investigate the effect of a break in music exposure on temporary threshold shifts. A cross-over design where subjects are exposed to dance music for either two hours consecutively, or exposed to two hours of dance music with a one-hour break in between. Outcome measure was the change in hearing threshold, measured in 1-dB steps at different time points after ending the music. Eighteen normal-hearing subjects participated in this study. Changes in pure-tone threshold were observed in both conditions and were similar, regardless of the break. Threshold shifts could be averaged for 1000, 2000, and 4000 Hz. The shift immediately after the ending of the music was 1.7 dB for right ears, and 3.4 dB for left ears. The difference between left and right ears was significant. One hour after the exposure, right ears were recovered to baseline conditions whereas left ears showed a small but clinically irrelevant remaining shift of approximately 1 dB. The advice to use chill-out zones is still valid, because this helps to reduce the duration to the exposure. This study does not provide evidence that a rest period gives an additional reduction of temporary threshold shifts.
Chen, Jerry Yongqiang; Zhou, Zhihong; Ang, Benjamin Fu Hong; Yew, Andy Khye Soon; Chou, Siaw Meng; Chia, Shi-Lu; Koh, Joyce Suang Bee; Howe, Tet Sen
2015-12-01
To compare the stiffness of locking compression plate (LCP) constructs with or without drilling the near cortex with elongated figure-of-8 holes. 24 synthetic bones were sawn to create a 10-mm gap and were fixed with a 9-hole 4.5-mm narrow LCP. In 12 bones, the near cortex of the adjacent holes to the LCP holes was drilled to create elongated figure-of-8 holes before screw insertion. The stiffness of LCP constructs under axial loading or 4-point bending was assessed by (1) dynamic quasi-physiological testing for fatigue strength, (2) quasi-static testing for stiffness, and (3) testing for absolute strength to failure. None of the 24 constructs had subcatastrophic or catastrophic failure after 10 000 cycles of fatigue loading (p=1.000). The axial stiffness reduced by 16% from 613±62 to 517±44 N/mm (p=0.012) in the case group, whereas the bending stiffness was 16±1 Nm2 in both groups (p=1.000). The maximum axial load to catastrophic failure was 1596±84 N for the control group and 1627±48 N for the case group (p=0.486), whereas the maximum bending moment to catastrophic failure was 79±12 and 80±10 Nm, respectively (p=0.919). Drilling the near cortex with elongated figure-of-8 holes reduces the axial stiffness of the LCP construct, without compromising its bending stiffness or strength.
Fixed-Rate Compressed Floating-Point Arrays.
Lindstrom, Peter
2014-12-01
Current compression schemes for floating-point data commonly take fixed-precision values and compress them to a variable-length bit stream, complicating memory management and random access. We present a fixed-rate, near-lossless compression scheme that maps small blocks of 4(d) values in d dimensions to a fixed, user-specified number of bits per block, thereby allowing read and write random access to compressed floating-point data at block granularity. Our approach is inspired by fixed-rate texture compression methods widely adopted in graphics hardware, but has been tailored to the high dynamic range and precision demands of scientific applications. Our compressor is based on a new, lifted, orthogonal block transform and embedded coding, allowing each per-block bit stream to be truncated at any point if desired, thus facilitating bit rate selection using a single compression scheme. To avoid compression or decompression upon every data access, we employ a software write-back cache of uncompressed blocks. Our compressor has been designed with computational simplicity and speed in mind to allow for the possibility of a hardware implementation, and uses only a small number of fixed-point arithmetic operations per compressed value. We demonstrate the viability and benefits of lossy compression in several applications, including visualization, quantitative data analysis, and numerical simulation.
Mammographic compression in Asian women.
Lau, Susie; Abdul Aziz, Yang Faridah; Ng, Kwan Hoong
2017-01-01
To investigate: (1) the variability of mammographic compression parameters amongst Asian women; and (2) the effects of reducing compression force on image quality and mean glandular dose (MGD) in Asian women based on phantom study. We retrospectively collected 15818 raw digital mammograms from 3772 Asian women aged 35-80 years who underwent screening or diagnostic mammography between Jan 2012 and Dec 2014 at our center. The mammograms were processed using a volumetric breast density (VBD) measurement software (Volpara) to assess compression force, compression pressure, compressed breast thickness (CBT), breast volume, VBD and MGD against breast contact area. The effects of reducing compression force on image quality and MGD were also evaluated based on measurement obtained from 105 Asian women, as well as using the RMI156 Mammographic Accreditation Phantom and polymethyl methacrylate (PMMA) slabs. Compression force, compression pressure, CBT, breast volume, VBD and MGD correlated significantly with breast contact area (p<0.0001). Compression parameters including compression force, compression pressure, CBT and breast contact area were widely variable between [relative standard deviation (RSD)≥21.0%] and within (p<0.0001) Asian women. The median compression force should be about 8.1 daN compared to the current 12.0 daN. Decreasing compression force from 12.0 daN to 9.0 daN increased CBT by 3.3±1.4 mm, MGD by 6.2-11.0%, and caused no significant effects on image quality (p>0.05). Force-standardized protocol led to widely variable compression parameters in Asian women. Based on phantom study, it is feasible to reduce compression force up to 32.5% with minimal effects on image quality and MGD.
76 FR 71892 - Broadband Over Power Lines
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-21
... Commission to: (1) Make part of the rulemaking record unredacted versions of several staff technical studies... public comment on those studies, and (3) provide a reasoned explanation of its choice of the... Phase 1 Study that show that the noise floor would rise by more than 20 dB at nearly all points, and by...
Access to Microsoft Windows 95 for Persons with Low Vision: An Overview.
ERIC Educational Resources Information Center
Shragai, Y.
1995-01-01
This article examines Windows 95, pointing out differences and improvements from Windows 3.1 for persons with low vision. Windows 95 is seen as providing substantially greater accessibility than Windows 3.1, though the graphical user interface may still pose serious problems for some users with low vision. (DB)
Ma, Lei; Zhang, Di; Chen, Wei; Shen, Yong; Zhang, Yingze; Ding, Wenyuan; Zhang, Wei; Wang, Linfeng; Yang, Dalong
2014-01-01
Cervical spondylotic myelopathy (CSM) is a common cause of disability in elderly patients. Previous studies have shown that spinal cord cell apoptosis due to spinal cord compression plays an important role in the pathology of myelopathy. Although changes in magnetic resonance imaging (MRI) T2 signal intensity ratio (SIR) are considered to be an indicator of CSM, little information is published supporting the correlation between changes in MRI signal and pathological changes. This study aims to testify the correlation between MRI T2 SIR changes and cell apoptosis using a CSM animal model. Forty-eight rabbits were randomly assigned to four groups: one control group and three experimental chronic compression groups, with each group containing 12 animals. Chronic compression of the cervical spinal cord was implemented in the experimental groups by implanting a screw in the C3 vertebra. The control group underwent sham surgery. Experimental groups were observed for 3, 6, or 9 months after surgery. MRI T2-weighted SIR Tarlov motor scores and cortical somatosensory-evoked potentials (CSEPs) were periodically monitored. At each time point, rabbits from one group were sacrificed to determine the level of apoptosis by histology (n = 6) and Western blotting (n = 6). Tarlov motor scores in the compression groups were lower at all time points than the control group scores, with the lowest score at 9 months (P < 0.001). Electrophysiological testing showed a significantly prolonged latency in CSEP in the compression groups compared with the control group. All rabbits in the compression groups showed higher MRI T2 SIR in the injury epicenter compared with controls, and higher SIR was also found at 9 months compared with 3 or 6 months. Histological analysis showed significant apoptosis in the spinal cord tissue in the compression groups, but not in the control group. There were significant differences in apoptosis degree over time (P < 0.001), with the 9-month group displaying the most severe spinal cord apoptosis. Spearman's rank correlation test showed that there was close relation between MRI SIR and degree of caspase-3 expression in Western blotting (r = 0.824. P < 0.001). Clear apoptosis of spinal cord tissue was observed during chronic focal spinal compression. Changes in MRI T2 SIR may be related to the severity of the apoptosis in cervical spinal cord.
Buechner, Andreas; Dyballa, Karl-Heinz; Hehrmann, Phillipp; Fredelake, Stefan; Lenarz, Thomas
2014-01-01
Objective To investigate the performance of monaural and binaural beamforming technology with an additional noise reduction algorithm, in cochlear implant recipients. Method This experimental study was conducted as a single subject repeated measures design within a large German cochlear implant centre. Twelve experienced users of an Advanced Bionics HiRes90K or CII implant with a Harmony speech processor were enrolled. The cochlear implant processor of each subject was connected to one of two bilaterally placed state-of-the-art hearing aids (Phonak Ambra) providing three alternative directional processing options: an omnidirectional setting, an adaptive monaural beamformer, and a binaural beamformer. A further noise reduction algorithm (ClearVoice) was applied to the signal on the cochlear implant processor itself. The speech signal was presented from 0° and speech shaped noise presented from loudspeakers placed at ±70°, ±135° and 180°. The Oldenburg sentence test was used to determine the signal-to-noise ratio at which subjects scored 50% correct. Results Both the adaptive and binaural beamformer were significantly better than the omnidirectional condition (5.3 dB±1.2 dB and 7.1 dB±1.6 dB (p<0.001) respectively). The best score was achieved with the binaural beamformer in combination with the ClearVoice noise reduction algorithm, with a significant improvement in SRT of 7.9 dB±2.4 dB (p<0.001) over the omnidirectional alone condition. Conclusions The study showed that the binaural beamformer implemented in the Phonak Ambra hearing aid could be used in conjunction with a Harmony speech processor to produce substantial average improvements in SRT of 7.1 dB. The monaural, adaptive beamformer provided an averaged SRT improvement of 5.3 dB. PMID:24755864
A preliminary assessment of noise level during Deepawali festival in Balasore, India.
Goswami, Shreerup; Swain, Bijay Kumar; Mohapatra, Hara Prasad; Bal, Kshirod Kumar
2013-11-01
A preliminary assessment of noise levels during Deepawali, was made in the present study. In order to assess the situation of noise levels in and around Balasore during two consecutive Deepawali of the year 2010 and 2011; noise monitoring was carried out in three different specified times (4:30-7:00 p.m., 7:00-10:30 p.m., 10:30 p.m.-1:00 a.m.). Noise descriptors such as L10, L50, L90, Leq, noise pollution level and noise climate were assessed to reveal the extent of noise pollution in this festival of crackers. Permissible limit of noise levels (Leq) prescribed by WHO during the festival was 100 dB and Lmax must not exceed 110 dB during such occasion. However, in all the cases Lmax and NPL values exceeded 110 dB, while Leq values ranged from 92.9 to 101.9 dB during 2010 Deepawali and 81.5 to 100.8 dB during 2011 Deepawali. On the other hand, all the noise monitoring sites belonged to residential areas. The assessed noise levels during such festivity are much more than 55/45 dB i.e. prescribed for residential areas for day/night time by CPCB. However, it was observed that the noise of Deepawali (Leq) decreased considerably and was less during 2011 than 2010. These may be due to increased environmental awareness among the public. Subsequently, the people of Balasore prefered to celebrate Deepawali, the festival of lights without sound and smoke. Noise policy should also be worked out for a better understanding of such local, social and cultural festivals in which annoyance arise.
DrugMetZ DB: an anthology of human drug metabolizing Chytochrome P450 enzymes.
Antony, Tresa Remya Thomas; Nagarajan, Shanthi
2006-11-14
Understandings the basics of Cytochrome P450 (P450 or CYP) will help to discern drug metabolism. CYP, a super-family of heme-thiolate proteins, are found in almost all living organisms and is involved in the biotransformation of a diverse range of xenobiotics, therapeutic drugs and toxins. Here, we describe DrugMetZ DB, a database for CYP metabolizing drugs. The DB is implemented in MySQL, PHP and HTML. www.bicpu.edu.in/DrugMetZDB/
A novel wavelength multiplexer/demutiplexer based on side-port multimode interference coupler
NASA Astrophysics Data System (ADS)
Wei, Shile; Jian, Wu; Zhao, Lingjuan; Qiu, Jifang; Yin, Zuoshan; Hui, Rongqing
2014-05-01
Based on side-port multimode interference coupler, a novel design of 1.31/1.55-μm wavelength multiplexer/demutiplexer on SOI platform with conventional channel waveguides is proposed and analyzed by using wide-angle beam propagation method. With a 25.9μm long ultra-short MMI section, nearly an order of magnitude shorter than that of the previously reported 1.31/1.55-μm wavelength MMI splitters on SOI, simulation results exhibit contrasts of 28dB and 25dB at wavelength 1.31 and 1.55 μm, respectively, and the insertion losses are both below 0.55dB. Meanwhile, the analysis shows that the proposed structure has larger fabrication tolerances than restricted MMI based structures and the present design methodology also applies to split other wavelengths and in different material platforms, such as InP, GaAs and PLC guides, etc.
Thennarasu, G; Sivasamy, A
2016-12-01
Stringent Environmental standards followed worldwide led to the emergence of advanced oxidation process for the removal of toxic contaminants from water and wastewater. Among all semiconductor photocatalysts have great potential in the degradation of organic and inorganic pollutants into lesser harmful products under visible light irradiations. The present research work describes the synthesis of Cu doped ZnO (CuDZ) via a co-precipitation method to attain high crystallized powder confirmed by XRD analysis. The FE-SEM images showed that the CuDZ has cotton ball like morphology with a uniform size ranged from 25 to 40nm. TEM, FT-IR and UV-DRS studies of the synthesized CuDZ are also discussed in detail. The photocatalytic activity of the as prepared CuDZ catalyst was tested for the degradation of Direct Blue 71 (DB 71) dye in aqueous phase under visible light irradiation. The degree of degradation was found to be dependent on aqueous phase pH, duration of irradiation time, amount of photocatalyst, the initial dye concentration and kinetics of photodegradation. The maximum photocatytic degradation of DB 71 dye was found to be effective at pH 6.8. The optimum amount of photocatalyst was found 3gL -1 of CuDZ for the complete degradation of DB 71 dye (0.01gL -1 ). The reusability of the photocatalyst indicates that 96% of DB 71 dye was degraded up to 3rd cycles of use. The visible photodegradation of DB 71 dye was exhibited pseudo-first-order kinetics. Chemical oxygen demand and ESI-MS studies confirmed the complete mineralization of DB 71 dye molecules. Copyright © 2015 Elsevier Inc. All rights reserved.
Um, Jihyun; Yu, Jinyeong; Park, Ki-Sook
2017-01-01
Wound healing is delayed in diabetes due to a number of factors, including impaired angiogenesis and poor dermal healing. The present study demonstrated that subcutaneous administration of substance P (SP) accelerates wound healing in db/db type 2 diabetic mice (db/db mice). SP injection (10 nM/kg, subcutaneously) enhanced angiogenesis, induced the mobilization of endothelial progenitor cells (EPCs) and increased the number of EPC-colony forming units (EPC-CFUs) in the bone marrow of db/db mice. Immunohistochemistry was performed to check the effects of SP on the cellular proliferation and the subcellular localization of Yes-associated protein (YAP) in the wound dermis. SP also upregulated cellular proliferation in the injured dermis of db/db mice. Compared with the control group, an increased number of cells in the wound dermis of SP-treated mice exhibited nuclear localization of YAP, which induces cellular proliferation. The results of the current study indicate that subcutaneous administration of SP may be a promising therapeutic strategy to treat diabetic wounds exhibiting impaired angiogenesis and dysfunctional dermal wound healing. PMID:28339006
Wang, Yishan; Doleschel, Sammy; Wunderlich, Ralf; Heinen, Stefan
2016-07-01
In this paper, a wearable and wireless ECG system is firstly designed with Bluetooth Low Energy (BLE). It can detect 3-lead ECG signals and is completely wireless. Secondly the digital Compressed Sensing (CS) is implemented to increase the energy efficiency of wireless ECG sensor. Different sparsifying basis, various compression ratio (CR) and several reconstruction algorithms are simulated and discussed. Finally the reconstruction is done by the android application (App) on smartphone to display the signal in real time. The power efficiency is measured and compared with the system without CS. The optimum satisfying basis built by 3-level decomposed db4 wavelet coefficients, 1-bit Bernoulli random matrix and the most suitable reconstruction algorithm are selected by the simulations and applied on the sensor node and App. The signal is successfully reconstructed and displayed on the App of smartphone. Battery life of sensor node is extended from 55 h to 67 h. The presented wireless ECG system with CS can significantly extend the battery life by 22 %. With the compact characteristic and long term working time, the system provides a feasible solution for the long term homecare utilization.
Real-Time Mobile Device-Assisted Chest Compression During Cardiopulmonary Resuscitation.
Sarma, Satyam; Bucuti, Hakiza; Chitnis, Anurag; Klacman, Alex; Dantu, Ram
2017-07-15
Prompt administration of high-quality cardiopulmonary resuscitation (CPR) is a key determinant of survival from cardiac arrest. Strategies to improve CPR quality at point of care could improve resuscitation outcomes. We tested whether a low cost and scalable mobile phone- or smart watch-based solution could provide accurate measures of compression depth and rate during simulated CPR. Fifty health care providers (58% intensive care unit nurses) performed simulated CPR on a calibrated training manikin (Resusci Anne, Laerdal) while wearing both devices. Subjects received real-time audiovisual feedback from each device sequentially. Primary outcome was accuracy of compression depth and rate compared with the calibrated training manikin. Secondary outcome was improvement in CPR quality as defined by meeting both guideline-recommend compression depth (5 to 6 cm) and rate (100 to 120/minute). Compared with the training manikin, typical error for compression depth was <5 mm (smart phone 4.6 mm; 95% CI 4.1 to 5.3 mm; smart watch 4.3 mm; 95% CI 3.8 to 5.0 mm). Compression rates were similarly accurate (smart phone Pearson's R = 0.93; smart watch R = 0.97). There was no difference in improved CPR quality defined as the number of sessions meeting both guideline-recommended compression depth (50 to 60 mm) and rate (100 to 120 compressions/minute) with mobile device feedback (60% vs 50%; p = 0.3). Sessions that did not meet guideline recommendations failed primarily because of inadequate compression depth (46 ± 2 mm). In conclusion, a mobile device application-guided CPR can accurately track compression depth and rate during simulation in a practice environment in accordance with resuscitation guidelines. Copyright © 2017 Elsevier Inc. All rights reserved.
Investigation of the relationship between aircraft noise and community annoyance in China.
Guoqing, Di; Xiaoyi, Liu; Xiang, Shi; Zhengguang, Li; Qili, Lin
2012-01-01
A survey of community annoyance induced by aircraft noise exposure was carried out around Hangzhou Xiaoshan International Airport. To investigate the relationship curves between aircraft noise and the percentage of "highly annoyed" persons in China and also to get annoyance threshold of aircraft noise in China. Noise annoyance induced by aircraft noise exposure was assessed by 764 local residents around the airport using the International Commission on Biological Effect of Noise (ICBEN) scale. The status quo of aircraft noise pollution was measured by setting up 39 monitoring points. The interpolation was used to estimate the weighted effective continuous perceived noise levels (LWECPN) in different areas around the airport, and the graph of equal noise level contour was drawn. The membership function was used to calculate the annoyance threshold of aircraft noise. Data were analyzed using SPSS 16.0 and Origin 8.0. The results showed that if LWECPN was 64.3 dB (Ldn was 51.4 dB), then 15% respondents were highly annoyed. If LWECPN was 68.1 dB (Ldn was 55.0 dB), then 25% respondents were highly annoyed. The annoyance threshold of aircraft noise (LWECPN) was 73.7 dB, while the annoyance threshold of a single flight incident instantaneous noise level (LAmax) was 72.9 dB. People around the airport had felt annoyed before the aircraft noise LWECPN reached the standard limit.
NASA Astrophysics Data System (ADS)
Lo, Mu-Chieh; Guzmán, Robinson; Ali, Muhsin; Santos, Rui; Augustin, Luc; Carpintero, Guillermo
2017-10-01
We report on an optical frequency comb with 14nm (~1.8 THz) spectral bandwidth at -3 dB level that is generated using a passively mode-locked quantum-well (QW) laser in photonic integrated circuits (PICs) fabricated through an InP generic photonic integration technology platform. This 21.5-GHz colliding-pulse mode-locked laser cavity is defined by on-chip reflectors incorporating intracavity phase modulators followed by an extra-cavity SOA as booster amplifier. A 1.8-THz-wide optical comb spectrum is presented with ultrafast pulse that is 0.35-ps-wide. The radio frequency beat note has a 3-dB linewidth of 450 kHz and 35-dB SNR.
Acoustical Techniques/Designs Investigated During the Southeast Asia Conflict 1966-1972
1981-01-21
the inbuoy processor above, the three sensor channels, two directional and one omni, are multi - plexed together and via the RF link transmitted back to...width at the 10 db dco;.n points and mnximtum side lobe level of -15 db) requires at least six’ elements in the line. At a geometric wean frequency of...presentation provides the data to the operator in the most accessible format. The vehicle descriptors are easily extracted with the aid of multi -point
Compression of thick laminated composite beams with initial impact-like damage
NASA Technical Reports Server (NTRS)
Breivik, N. L.; Guerdal, Z.; Griffin, O. H., Jr.
1992-01-01
While the study of compression after impact of laminated composites has been under consideration for many years, the complexity of the damage initiated by low velocity impact has not lent itself to simple predictive models for compression strength. The damage modes due to non-penetrating, low velocity impact by large diameter objects can be simulated using quasi-static three-point bending. The resulting damage modes are less coupled and more easily characterized than actual impact damage modes. This study includes the compression testing of specimens with well documented initial damage states obtained from three-point bend testing. Compression strengths and failure modes were obtained for quasi-isotropic stacking sequences from 0.24 to 1.1 inches thick with both grouped and interspersed ply stacking. Initial damage prior to compression testing was divided into four classifications based on the type, extent, and location of the damage. These classifications are multiple through-thickness delaminations, isolated delamination, damage near the surface, and matrix cracks. Specimens from each classification were compared to specimens tested without initial damage in order to determine the effects of the initial damage on the final compression strength and failure modes. A finite element analysis was used to aid in the understanding and explanation of the experimental results.
CMOS analog baseband circuitry for an IEEE 802.11 b/g/n WLAN transceiver
NASA Astrophysics Data System (ADS)
Zheng, Gong; Xiaojie, Chu; Qianqian, Lei; Min, Lin; Yin, Shi
2012-11-01
An analog baseband circuit for a direct conversion wireless local area network (WLAN) transceiver in a standard 0.13-μm CMOS occupying 1.26 mm2 is presented. The circuit consists of active-RC receiver (RX) 4th order elliptic lowpass filters(LPFs), transmit (PGAs) with DC offset cancellation (DCOC) servo loops, and on-chip output buffers. The RX baseband gain can be programmed in the range of -11 to 49 dB in 2 dB steps with 50-30.2 nV/√Hz input referred noise (IRN) and a 21 to -41 dBm in-band 3rd order interception point (IIP3). The RX/TX LPF cutoff frequencies can be switched between 5 MHz, 10 MHz, and 20 MHz to fulfill the multimode 802.11b/g/n requirements. The TX baseband gain of the I/Q paths are tuned separately from -1.6 to 0.9 dB in 0.1 dB steps to calibrate TX I/Q gain mismatches. By using an identical integrator based elliptic filter synthesis method together with global compensation applied to the LPF capacitor array, the power consumption of the RX LPF is considerably reduced and the proposed chip draws 26.8 mA/8 mA by the RX/TX baseband paths from a 1.2 V supply.
Belghith, Akram; Bowd, Christopher; Medeiros, Felipe A; Hammel, Naama; Yang, Zhiyong; Weinreb, Robert N; Zangwill, Linda M
2016-02-01
We determined if the Bruch's membrane opening (BMO) location changes over time in healthy eyes and eyes with progressing glaucoma, and validated an automated segmentation algorithm for identifying the BMO in Cirrus high-definition coherence tomography (HD-OCT) images. We followed 95 eyes (35 progressing glaucoma and 60 healthy) for an average of 3.7 ± 1.1 years. A stable group of 50 eyes had repeated tests over a short period. In each B-scan of the stable group, the BMO points were delineated manually and automatically to assess the reproducibility of both segmentation methods. Moreover, the BMO location variation over time was assessed longitudinally on the aligned images in 3D space point by point in x, y, and z directions. Mean visual field mean deviation at baseline of the progressing glaucoma group was -7.7 dB. Mixed-effects models revealed small nonsignificant changes in BMO location over time for all directions in healthy eyes (the smallest P value was 0.39) and in the progressing glaucoma eyes (the smallest P value was 0.30). In the stable group, the overall intervisit-intraclass correlation coefficient (ICC) and coefficient of variation (CV) were 98.4% and 2.1%, respectively, for the manual segmentation and 98.1% and 1.9%, respectively, for the automated algorithm. Bruch's membrane opening location was stable in normal and progressing glaucoma eyes with follow-up between 3 and 4 years indicating that it can be used as reference point in monitoring glaucoma progression. The BMO location estimation with Cirrus HD-OCT using manual and automated segmentation showed excellent reproducibility.
Chou, Jonathan C.; Rollins, Stuart D.; Ye, Minghao; Batlle, Daniel; Fawzi, Amani A.
2014-01-01
Purpose. We sought to determine the effects of atrasentan, a selective endothelin-A receptor antagonist, on the retinal vascular and structural integrity in a db/db mouse, an animal model of type 2 diabetes and diabetic retinopathy. Methods. Diabetic mice, 23 weeks old, were given either atrasentan or vehicle treatment in drinking water for 8 weeks. At the end of the treatment period, eyes underwent trypsin digest to assess the retinal vascular pathology focusing on capillary degeneration, endothelial cell, and pericyte loss. Paraffin-embedded retinal cross sections were used to evaluate retinal sublayer thickness both near the optic nerve and in the retinal periphery. Immunohistochemistry and TUNEL assay were done to evaluate retinal cellular and vascular apoptosis. Results. Compared with untreated db/db mice, atrasentan treatment was able to ameliorate the retinal vascular pathology by reducing pericyte loss (29.2% ± 0.4% vs. 44.4% ± 2.0%, respectively, P < 0.05) and capillary degeneration as determined by the percentage of acellular capillaries (8.6% ± 0.3% vs. 3.3% ± 0.41%, respectively, P < 0.05). A reduction in inner retinal thinning both at the optic nerve and at the periphery in treated diabetic mice was also observed in db/db mice treated with atrasentan as compared with untreated db/db mice (P < 0.05). TUNEL assay suggested that atrasentan may decrease enhanced apoptosis in neuroretinal layers and vascular pericytes in the db/db mice. Conclusions. Endothelin-A receptor blockade using atrasentan significantly reduces the vascular and neuroretinal complications in diabetic mice. Endothelin-A receptor blockade is a promising therapeutic target in diabetic retinopathy. PMID:24644048
Predicting failure: acoustic emission of berlinite under compression.
Nataf, Guillaume F; Castillo-Villa, Pedro O; Sellappan, Pathikumar; Kriven, Waltraud M; Vives, Eduard; Planes, Antoni; Salje, Ekhard K H
2014-07-09
Acoustic emission has been measured and statistical characteristics analyzed during the stress-induced collapse of porous berlinite, AlPO4, containing up to 50 vol% porosity. Stress collapse occurs in a series of individual events (avalanches), and each avalanche leads to a jerk in sample compression with corresponding acoustic emission (AE) signals. The distribution of AE avalanche energies can be approximately described by a power law p(E)dE = E(-ε)dE (ε ~ 1.8) over a large stress interval. We observed several collapse mechanisms whereby less porous minerals show the superposition of independent jerks, which were not related to the major collapse at the failure stress. In highly porous berlinite (40% and 50%) an increase of energy emission occurred near the failure point. In contrast, the less porous samples did not show such an increase in energy emission. Instead, in the near vicinity of the main failure point they showed a reduction in the energy exponent to ~ 1.4, which is consistent with the value reported for compressed porous systems displaying critical behavior. This suggests that a critical avalanche regime with a lack of precursor events occurs. In this case, all preceding large events were 'false alarms' and unrelated to the main failure event. Our results identify a method to use pico-seismicity detection of foreshocks to warn of mine collapse before the main failure (the collapse) occurs, which can be applied to highly porous materials only.
Portable Dynamic Pressure Calibrator
NASA Technical Reports Server (NTRS)
Wright, Morgan S.; Maynard, Everett (Technical Monitor)
1996-01-01
A portable, dynamic pressure calibrator was fabricated for use on wind tunnel models at NASA-Ames Research Center. The calibrator generates sine wave pressures at levels up to 1 PSIG P-P(168dB) at frequencies from 10Hz to 6KHz and .5 PSIG P.P (162dB) at frequencies from 6KHz to 20KHz. The calibrator consists of two units connected by a single cable. The handheld unit contains a pressure transducer, speaker, and deadman switch. This unit allows application of dynamic pressure to transducers/ports on installed wind tunnel models. The base unit contains all of power supplies, controls and displays. This unit allows amplitude and frequency to be set and verified at a safe location off of the model.
Lagrangian statistics in compressible isotropic homogeneous turbulence
NASA Astrophysics Data System (ADS)
Yang, Yantao; Wang, Jianchun; Shi, Yipeng; Chen, Shiyi
2011-11-01
In this work we conducted the Direct Numerical Simulation (DNS) of a forced compressible isotropic homogeneous turbulence and investigated the flow statistics from the Lagrangian point of view, namely the statistics is computed following the passive tracers trajectories. The numerical method combined the Eulerian field solver which was developed by Wang et al. (2010, J. Comp. Phys., 229, 5257-5279), and a Lagrangian module for tracking the tracers and recording the data. The Lagrangian probability density functions (p.d.f.'s) have then been calculated for both kinetic and thermodynamic quantities. In order to isolate the shearing part from the compressing part of the flow, we employed the Helmholtz decomposition to decompose the flow field (mainly the velocity field) into the solenoidal and compressive parts. The solenoidal part was compared with the incompressible case, while the compressibility effect showed up in the compressive part. The Lagrangian structure functions and cross-correlation between various quantities will also be discussed. This work was supported in part by the China's Turbulence Program under Grant No.2009CB724101.
On the analysis of shock implosion
NASA Astrophysics Data System (ADS)
Mishkin, Eli A.; Alejaldre, Carlos
1984-06-01
An imploding shock wave, coming from infinity, moves through an ideal gas with the adiabatic constant γ. To define a single-valued self-similar coefficient λ(γ), over the whole classical interval 1 < γ < ∞, its boundary values λ(1), λ(∞) are deduced. The conservation equations, cast in form of quadratics, exhibit their singular points P,M,M‧. At P the pressure is maximum, at M the velocity of the gas U1, minus ξ, equals the speed of sound C, at M‧ there is a linear relationship between U1, U˙1 and C. The representative curve of the compressed gas passes analytically through all of them. The relative position of P, M, M‧ leads to three solutions of the quadratic conservation equations. Representative curves of the state of the imploded gas, at various values of γ, are shown. The errors associated with the idealized models of implosion and explosion are evaluated.
Rekhi, G S; Nellore, R V; Hussain, A S; Tillman, L G; Malinowski, H J; Augsburger, L L
1999-06-02
The objective of this study, was to examine the influence of critical formulation and processing variables as described in the AAPS/FDA Workshop II report on scale-up of oral extended-release dosage forms, using a hydrophilic polymer hydroxypropyl methylcellulose (Methocel K100LV). A face-centered central composite design (26 runs+3 center points) was selected and the variables studied were: filler ratio (lactose:dicalcium phosphate (50:50)), polymer level (15/32.5/50%), magnesium stearate level (1/1.5/2%), lubricant blend time (2/6/10 min) and compression force (400/600/800 kg). Granulations (1.5 kg, 3000 units) were manufactured using a fluid-bed process, lubricated and tablets (100 mg metoprolol tartrate) were compressed on an instrumented Manesty D3B rotary tablet press. Dissolution tests were performed using USP apparatus 2, at 50 rpm in 900 ml phosphate buffer (pH 6.8). Responses studied included percent drug released at Q1 (1 h), Q4, Q6, Q12. Analysis of variance indicated that change in polymer level was the most significant factor affecting drug release. Increase in dicalcium phosphate level and compression force were found to affect the percent released at the later dissolution time points. Some interaction effects between the variables studied were also found to be statistically significant. The drug release mechanism was predominantly found to be Fickian diffusion controlled (n=0.46-0.59). Response surface plots and regression models were developed which adequately described the experimental space. Three formulations having slow-, medium- and fast-releasing dissolution profiles were identified for a future bioavailability/bioequivalency study. The results of this study provided the framework for further work involving both in vivo studies and scale-up.
A Double Dwell High Sensitivity GPS Acquisition Scheme Using Binarized Convolution Neural Network
Wang, Zhen; Zhuang, Yuan; Yang, Jun; Zhang, Hengfeng; Dong, Wei; Wang, Min; Hua, Luchi; Liu, Bo; Shi, Longxing
2018-01-01
Conventional GPS acquisition methods, such as Max selection and threshold crossing (MAX/TC), estimate GPS code/Doppler by its correlation peak. Different from MAX/TC, a multi-layer binarized convolution neural network (BCNN) is proposed to recognize the GPS acquisition correlation envelope in this article. The proposed method is a double dwell acquisition in which a short integration is adopted in the first dwell and a long integration is applied in the second one. To reduce the search space for parameters, BCNN detects the possible envelope which contains the auto-correlation peak in the first dwell to compress the initial search space to 1/1023. Although there is a long integration in the second dwell, the acquisition computation overhead is still low due to the compressed search space. Comprehensively, the total computation overhead of the proposed method is only 1/5 of conventional ones. Experiments show that the proposed double dwell/correlation envelope identification (DD/CEI) neural network achieves 2 dB improvement when compared with the MAX/TC under the same specification. PMID:29747373
DWT-Based High Capacity Audio Watermarking
NASA Astrophysics Data System (ADS)
Fallahpour, Mehdi; Megías, David
This letter suggests a novel high capacity robust audio watermarking algorithm by using the high frequency band of the wavelet decomposition, for which the human auditory system (HAS) is not very sensitive to alteration. The main idea is to divide the high frequency band into frames and then, for embedding, the wavelet samples are changed based on the average of the relevant frame. The experimental results show that the method has very high capacity (about 5.5kbps), without significant perceptual distortion (ODG in [-1, 0] and SNR about 33dB) and provides robustness against common audio signal processing such as added noise, filtering, echo and MPEG compression (MP3).
Raman dissipative soliton fiber laser pumped by an ASE source.
Pan, Weiwei; Zhang, Lei; Zhou, Jiaqi; Yang, Xuezong; Feng, Yan
2017-12-15
The mode locking of a Raman fiber laser with an amplified spontaneous emission (ASE) pump source is investigated for performance improvement. Raman dissipative solitons with a compressed pulse duration of 1.05 ps at a repetition rate of 2.47 MHz are generated by utilizing nonlinear polarization rotation and all-fiber Lyot filter. A signal-to-noise ratio as high as 85 dB is measured in a radio-frequency spectrum, which suggests excellent temporal stability. Multiple-pulse operation with unique random static distribution is observed for the first time, to the best of our knowledge, at higher pump power in mode-locked Raman fiber lasers.
NASA Astrophysics Data System (ADS)
Grudinin, A. B.; Dianov, Evgenii M.; Korobkin, D. V.; Prokhorov, A. M.; Semenov, V. A.; Khrushchev, I. Yu
1990-08-01
An experimental investigation was made of the process of amplification of femtosecond pulses in single-mode fiber waveguides activated with erbium ions. The amplified pulses were compressed from 80 to 55 fs in the course of their propagation. The energy of the pulses was estimated to be 5 nJ. The maximum gain was 26 dB.
Electronic topological transitions in Zn under compression
NASA Astrophysics Data System (ADS)
Kechin, Vladimir V.
2001-01-01
The electronic structure of hcp Zn under pressure up to 10 GPa has been calculated self-consistently by means of the scalar relativistic tight-binding linear muffin-tin orbital method. The calculations show that three electronic topological transitions (ETT's) occur in Zn when the c/a axial ratio diminishes under compression. One transition occurs at c/a~=1.82 when the ``needles'' appear around the symmetry point K of the Brillouin zone. The other two transitions occur at c/a~=3, when the ``butterfly'' and ``cigar'' appear simultaneously both around the L point. It has been shown that these ETT's are responsible for a number of anomalies observed in Zn at compression.
Noise analysis of the seismic system employed in the northern and southern California seismic nets
Eaton, J.P.
1984-01-01
The seismic networks have been designed and operated to support recording on Develocorders (less than 40db dynamic range) and analog magnetic tape (about 50 db dynamic range). The principal analysis of the records has been based on Develocorder films; and background earth noise levels have been adjusted to be about 1 to 2 mm p-p on the film readers. Since the traces are separated by only 10 to 12 mm on the reader screen, they become hopelessly tangled when signal amplitudes on several adjacent traces exceed 10 to 20 mm p-p. Thus, the background noise level is hardly more than 20 db below the level of largest readable signals. The situation is somewhat better on tape playbacks, but the high level of background noise set to accomodate processing from film records effectively limits the range of maximum-signal to background-earth-noise on high gain channels to a little more than 30 db. Introduction of the PDP 11/44 seismic data acquisition system has increased the potential dynamic range of recorded network signals to more than 60 db. To make use of this increased dynamic range we must evaluate the characteristics and performance of the seismic system. In particular, we must determine whether the electronic noise in the system is or can be made sufficiently low so that background earth noise levels can be lowered significantly to take advantage of the increased dynamic range of the digital recording system. To come to grips with the complex problem of system noise, we have carried out a number of measurements and experiments to evaluate critical components of the system as well as to determine the noise characteristics of the system as a whole.
Nitescu, Nicoletta; DiBona, Gerald F; Grimberg, Elisabeth; Guron, Gregor
2010-01-01
The aim was to examine the role of angiotensin II type 1 receptors in dynamic autoregulation of renal blood flow (RBF) in endotoxemia. Experiments were performed on anesthetized rats 16 h after intraperitoneal lipopolysaccharide (LPS) or vehicle administration. After baseline measurements, groups Sham-Saline, LPS-Saline and LPS-Candesartan received isotonic saline or candesartan (10 μg kg(-1) i.v.). Data were collected during eight consecutive 20-min clearance periods (C1-8). Transfer function (TF) analysis in the frequency domain was used to examine dynamic autoregulation of RBF. Endotoxemic rats showed an approximate 50% reduction in glomerular filtration rate (GFR) and RBF (p < 0.05 vs. Sham-Saline). Candesartan significantly increased RBF (+40 ± 6% vs. baseline; p < 0.05) but did not significantly influence GFR. Endotoxemic animals showed a normal myogenic response but had elevated TF gain values in the frequency range of the tubuloglomerular feedback mechanism (TGF; 0.01-0.03 Hz) reflecting impaired autoregulation (periods C3-4, 2.2 ± 1.6 vs. -2.6 ± 0.6 dB, p < 0.05, and C7-8, -0.4 ± 1.3 vs. -4.0 ± 0.8 dB, p < 0.05; in groups LPS-Saline and Sham-Saline, respectively). Candesartan normalized TF gain in this frequency range (periods C7-8, -6.1 ± 2.3 dB in group LPS-Candesartan, p < 0.05 vs. LPS-Saline). Candesartan ameliorates the adverse effect of endotoxin on the TGF component of dynamic autoregulation of RBF. Copyright © 2010 S. Karger AG, Basel.
Li, Yi; Qian, Li; Zhou, Ciming; Fan, Dian; Xu, Qiannan; Pang, Yandong; Chen, Xi; Tang, Jianguan
2018-01-12
Multi-point vibration sensing at the low frequency range of 0.5-100 Hz is of vital importance for applications such as seismic monitoring and underwater acoustic imaging. Location-resolved multi-point sensing using a single fiber and a single demodulation system can greatly reduce system deployment and maintenance costs. We propose and demonstrate the demodulation of a fiber-optic system consisting of 500 identical ultra-weak Fiber Bragg gratings (uwFBGs), capable of measuring the amplitude, frequency and phase of acoustic signals from 499 sensing fibers covering a total range of 2.5 km. For demonstration purposes, we arbitrarily chose six consecutive sensors and studied their performance in detail. Using a passive demodulation method, we interrogated the six sensors simultaneously, and achieved a high signal-to-noise ratio of 22.1 dB, excellent linearity, phase sensitivity of around 0.024 rad/Pa, and a dynamic range of about 38 dB. We demonstrated a frequency response flatness of <1.2 dB in the range of 0.5-100 Hz. Compared to the prior state-of-the-art demonstration using a similar method, we have increased the sensing range from 1 km to 2.5 km, and increased the frequency range from 0.4 octaves to 7.6 octaves, in addition to achieving sensing in the very challenging low-frequency range of 0.5-100 Hz.
NASA Technical Reports Server (NTRS)
Rowland, John R.; Goldhirsh, Julius; Vogel, Wolfhard J.; Torrence, Geoffrey W.
1991-01-01
An overview and a status description of the planned LMSS mobile K band experiment with ACTS is presented. As a precursor to the ACTS mobile measurements at 20.185 GHz, measurements at 19.77 GHz employing the Olympus satellite were originally planned. However, because of the demise of Olympus in June of 1991, the efforts described here are focused towards the ACTS measurements. In particular, we describe the design and testing results of a gyro controlled mobile-antenna pointing system. Preliminary pointing measurements during mobile operations indicate that the present system is suitable for measurements employing a 15 cm aperture (beamwidth at approximately 7 deg) receiving antenna operating with ACTS in the high gain transponder mode. This should enable measurements with pattern losses smaller than plus or minus 1 dB over more than 95 percent of the driving distance. Measurements with the present mount system employing a 60 cm aperture (beamwidth at approximately 1.7 deg) results in pattern losses smaller than plus or minus 3 dB for 70 percent of the driving distance. Acceptable propagation measurements may still be made with this system by employing developed software to flag out bad data points due to extreme pointing errors. The receiver system including associated computer control software has been designed and assembled. Plans are underway to integrate the antenna mount with the receiver on the University of Texas mobile receiving van and repeat the pointing tests on highways employing a recently designed radome system.
Hayes, Katherine L; Messina, Louis M; Schwartz, Lawrence M; Yan, Jinglian; Burnside, Amy S; Witkowski, Sarah
2018-05-01
Peripheral artery disease is an atherosclerotic occlusive disease that causes limb ischemia and has few effective noninterventional treatments. Stem cell therapy is promising, but concomitant diabetes may limit its effectiveness. We evaluated the therapeutic potential of skeletal muscle pericytes to augment postischemic neovascularization in wild-type and type 2 diabetic (T2DM) mice. Wild-type C57BL/6J and leptin receptor spontaneous mutation db/db T2DM mice underwent unilateral femoral artery excision to induce limb ischemia. Twenty-four hours after ischemia induction, CD45 - CD34 - CD146 + skeletal muscle pericytes or vehicle controls were transplanted into ischemic hindlimb muscles. At postoperative day 28, pericyte transplantation augmented blood flow recovery in wild-type mice (79.3 ± 5% vs. 61.9 ± 5%; P = 0.04), but not in T2DM mice (48.6% vs. 46.3 ± 5%; P = 0.51). Pericyte transplantation augmented collateral artery enlargement in wild-type (26.7 ± 2 μm vs. 22.3 ± 1 μm, P = 0.03), but not T2DM mice (20.4 ± 1.4 μm vs. 18.5 ± 1.2 μm, P = 0.14). Pericyte incorporation into collateral arteries was higher in wild-type than in T2DM mice ( P = 0.002). Unexpectedly, pericytes differentiated into Schwann cells in vivo. In vitro, Insulin increased Nox2 expression and decreased tubular formation capacity in human pericytes. These insulin-induced effects were reversed by N-acetylcysteine antioxidant treatment. In conclusion, T2DM impairs the ability of pericytes to augment neovascularization via decreased collateral artery enlargement and impaired engraftment into collateral arteries, potentially via hyperinsulinemia-induced oxidant stress. While pericytes show promise as a unique form of stem cell therapy to increase postischemic neovascularization, characterizing the molecular mechanisms by which T2DM impairs their function is essential to achieve their therapeutic potential.
MRI dynamic range and its compatibility with signal transmission media
Gabr, Refaat E.; Schär, Michael; Edelstein, Arthur D.; Kraitchman, Dara L.; Bottomley, Paul A.; Edelstein, William A.
2010-01-01
As the number of MRI phased array coil elements grows, interactions among cables connecting them to the system receiver become increasingly problematic. Fiber optic or wireless links would reduce electromagnetic interference, but their dynamic range (DR) is generally less than that of coaxial cables. Raw MRI signals, however, have a large DR because of the high signal amplitude near the center of k-space. Here, we study DR in MRI in order to determine the compatibility of MRI multicoil imaging with non-coaxial cable signal transmission. Since raw signal data are routinely discarded, we have developed an improved method for estimating the DR of MRI signals from conventional magnitude images. Our results indicate that the DR of typical surface coil signals at 3 T for human subjects is less than 88 dB, even for three-dimensional acquisition protocols. Cardiac and spine coil arrays had a maximum DR of less than 75 dB and head coil arrays less than 88 dB. The DR derived from magnitude images is in good agreement with that measured from raw data. The results suggest that current analog fiber optic links, with a spurious-free DR of 60–70 dB at 500 kHz bandwidth, are not by themselves adequate for transmitting MRI data from volume or array coils with DR ~90 dB. However, combining analog links with signal compression might make non-coaxial cable signal transmission viable. PMID:19251444
MRI dynamic range and its compatibility with signal transmission media.
Gabr, Refaat E; Schär, Michael; Edelstein, Arthur D; Kraitchman, Dara L; Bottomley, Paul A; Edelstein, William A
2009-06-01
As the number of MRI phased array coil elements grows, interactions among cables connecting them to the system receiver become increasingly problematic. Fiber optic or wireless links would reduce electromagnetic interference, but their dynamic range (DR) is generally less than that of coaxial cables. Raw MRI signals, however, have a large DR because of the high signal amplitude near the center of k-space. Here, we study DR in MRI in order to determine the compatibility of MRI multicoil imaging with non-coaxial cable signal transmission. Since raw signal data are routinely discarded, we have developed an improved method for estimating the DR of MRI signals from conventional magnitude images. Our results indicate that the DR of typical surface coil signals at 3T for human subjects is less than 88 dB, even for three-dimensional acquisition protocols. Cardiac and spine coil arrays had a maximum DR of less than 75 dB and head coil arrays less than 88 dB. The DR derived from magnitude images is in good agreement with that measured from raw data. The results suggest that current analog fiber optic links, with a spurious-free DR of 60-70 dB at 500 kHz bandwidth, are not by themselves adequate for transmitting MRI data from volume or array coils with DR approximately 90 dB. However, combining analog links with signal compression might make non-coaxial cable signal transmission viable.
Off-nadir antenna bias correction using Amazon rain sigma(0) data
NASA Technical Reports Server (NTRS)
Birrer, I. J.; Dome, G. J.; Sweet, J.; Berthold, G.; Moore, R. K.
1982-01-01
The radar response from the Amazon rain forest was studied to determine the suitability of this region for use as a standard target to calibrate a scatterometer like that proposed for the National Oceanic Satellite System (NOSS). Backscattering observations made by the SEASAT Scatterometer System (SASS) showed the Amazon rain forest to be a homogeneous, azimuthally-isotropic, radar target which was insensitive to polarization. The variation with angle of incidence was adequately modeled as scattering coefficient (dB) = a theta b with typical values for the incidence-angle coefficient from 0.07 to 0.15 dB/deg. A small diurnal effect occurs, with measurements at sunrise being 0.5 dB to 1 dB higher than the rest of the day. Maximum-likelihood estimation algorithms presented here permit determination of relative bias and true pointing angle for each beam. Specific implementation of these algorithms for the proposed NOSS scatterometer system is also discussed.
Kill, Clemens; Torossian, Alexander; Freisburger, Christian; Dworok, Sebastian; Massmann, Martin; Nohl, Thorsten; Henning, Ronald; Wallot, Pascal; Gockel, Andreas; Steinfeldt, Thorsten; Graf, Jürgen; Eberhart, Leopold; Wulf, Hinnerk
2009-09-01
During cardiac arrest the paramount goal of basic life support (BLS) is the oxygenation of vital organs. Current recommendations are to combine chest compressions with ventilation in a fixed ratio of 30:2; however the optimum compression/ventilation ratio is still debatable. In our study we compared four different compression/ventilation ratios and documented their effects on the return of spontaneous circulation (ROSC), gas exchange, cerebral tissue oxygenation and haemodynamics in a pig model. Study was performed on 32 pigs under general anaesthesia with endotracheal intubation. Arterial and central venous lines were inserted. For continuous cerebral tissue oxygenation a Licox PtiO(2) probe was implanted. After 3 min of cardiac arrest (ventricular fibrillation) animals were randomized to a compression/ventilation-ratio 30:2, 100:5, 100:2 or compressions-only. Subsequently 10 min BLS, Advanced Life Support (ALS) was performed (100%O(2), 3 defibrillations, 1mg adrenaline i.v.). Data were analyzed with 2-factorial ANOVA. ROSC was achieved in 4/8 (30:2), 5/8 (100:5), 2/8 (100:2) and 0/8 (compr-only) pigs. During BLS, PaCO(2) increased to 55 mm Hg (30:2), 68 mm Hg (100:5; p=0.0001), 66 mm Hg (100:2; p=0.002) and 72 mm Hg (compr-only; p<0.0001). PaO(2) decreased to 58 mmg (30:2), 40 mm Hg (100:5; p=0.15), 43 mm Hg (100:2; p=0.04) and 26 mm Hg (compr-only; p<0.0001). PtiO(2) baseline values were 12.7, 12.0, 11.1 and 10.0 mm Hg and decreased to 8.1 mm Hg (30:2), 4.1 mm Hg (100:5; p=0.08), 4.3 mm Hg (100:2; p=0.04), and 4.5 mm Hg (compr-only; p=0.69). During BLS, a compression/ventilation-ratio of 100:5 seems to be equivalent to 30:2, while ratios of 100:2 or compressions-only detoriate peripheral arterial oxygenation and reduce the chance for ROSC.
Shin, Lewis K; Jeffrey, R Brooke; Berry, Gerald J; Olcott, Eric W
2017-12-01
Purpose To test the hypothesis that appendiceal spectral Doppler waveforms can distinguish patients with and patients without appendicitis. Materials and Methods In this retrospective study, Doppler waveforms were obtained from intramural appendiceal arteries identified with color Doppler imaging in 60% (93 of 155) of consecutive patients whose appendices were visualized at graded compression ultrasonography (US) performed for suspected appendicitis (53 male and 40 female; age, 1-56 years; mean, 14.5 years) over the 5-month period from November 2015 through March 2016. Point, non-angle-corrected peak systolic velocity (PSV) and resistive index (RI) values were compared between patients with and patients without appendicitis by utilizing histopathologically proven appendicitis and 6-week clinical follow-up as diagnostic reference standards. Data were assessed by using the Student t test, exact binomial distribution, two-sample test of proportions, and receiver operating characteristic analysis. Results Among the 93 patients, 36 (38.7%) had proven appendicitis (mean PSV, 19.7 cm/sec; mean RI, 0.69) and 57 patients (61.2%) did not (mean PSV, 7.1 cm/sec, P < .0001; mean RI, 0.50, P < .0001). The area under the receiver operating characteristic curve for the diagnosis of appendicitis was 0.97 (95% confidence interval [CI]: 0.95, 1.00) for PSV and 0.86 (95% CI: 0.78, 0.95; P = .011) for RI. Chosen discriminatory criteria of PSV greater than 10 cm/sec and RI greater than 0.65 yielded specificity for appendicitis of 94.7% and 96.5% with sensitivity of 88.9% and 63.9% (P = .013) and negative predictive value of 93.1% and 80.9% (P = .045), respectively. Original clinical graded compression US interpretations based on established US findings demonstrated specificity of 96.2% and sensitivity of 100.0%. Considering the subset of 20 patients whose maximum outer diameter measured 6-8 mm, the discriminatory criteria of PSV greater than 10 cm/sec and RI greater than 0.65 yielded specificity for appendicitis of 88.9% each, with sensitivity of 100.0% and 63.6% and negative predictive value of 100.0% and 66.6%, respectively. Conclusion In patients with visualized appendices at US, those with appendicitis exhibit significantly higher point PSV and point RI values than do patients without appendicitis and are distinguishable with high specificity by using a PSV greater than 10 cm/sec and an RI greater than 0.65 as diagnostic criteria. © RSNA, 2017.
30 CFR 938.15 - Approval of Pennsylvania regulatory program amendments.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Subsidence and Land 2001 Conservation Act: Repeal of Section 4 (52 P.S. 1406.4); 5(b)(partial approval); 5.1...)); 5.2(a)(1), (2), and (3) (52 P.S. 1406.5b(a)(1), (2), and (3)); 5.2(b)(1) (52 P.S. 1406.5b(b)(1)); 5... approval); 5.4(a)(1), (2) and (4) (52 P.S. 1406.5d(a)(1), (2) and (4)); 5.4(b) (52 P.S. 1406.5d(b)); 5.5(a...
30 CFR 938.15 - Approval of Pennsylvania regulatory program amendments.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Subsidence and Land 2001 Conservation Act: Repeal of Section 4 (52 P.S. 1406.4); 5(b)(partial approval); 5.1...)); 5.2(a)(1), (2), and (3) (52 P.S. 1406.5b(a)(1), (2), and (3)); 5.2(b)(1) (52 P.S. 1406.5b(b)(1)); 5... approval); 5.4(a)(1), (2) and (4) (52 P.S. 1406.5d(a)(1), (2) and (4)); 5.4(b) (52 P.S. 1406.5d(b)); 5.5(a...
30 CFR 938.15 - Approval of Pennsylvania regulatory program amendments.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Subsidence and Land 2001 Conservation Act: Repeal of Section 4 (52 P.S. 1406.4); 5(b)(partial approval); 5.1...)); 5.2(a)(1), (2), and (3) (52 P.S. 1406.5b(a)(1), (2), and (3)); 5.2(b)(1) (52 P.S. 1406.5b(b)(1)); 5... approval); 5.4(a)(1), (2) and (4) (52 P.S. 1406.5d(a)(1), (2) and (4)); 5.4(b) (52 P.S. 1406.5d(b)); 5.5(a...
30 CFR 938.15 - Approval of Pennsylvania regulatory program amendments.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Subsidence and Land 2001 Conservation Act: Repeal of Section 4 (52 P.S. 1406.4); 5(b)(partial approval); 5.1...)); 5.2(a)(1), (2), and (3) (52 P.S. 1406.5b(a)(1), (2), and (3)); 5.2(b)(1) (52 P.S. 1406.5b(b)(1)); 5... approval); 5.4(a)(1), (2) and (4) (52 P.S. 1406.5d(a)(1), (2) and (4)); 5.4(b) (52 P.S. 1406.5d(b)); 5.5(a...
Elevated Steroid Hormone Production in the db/db Mouse Model of Obesity and Type 2 Diabetes.
Hofmann, Anja; Peitzsch, Mirko; Brunssen, Coy; Mittag, Jennifer; Jannasch, Annett; Frenzel, Annika; Brown, Nicholas; Weldon, Steven M; Eisenhofer, Graeme; Bornstein, Stefan R; Morawietz, Henning
2017-01-01
Obesity and type 2 diabetes have become a major public health problem worldwide. Steroid hormone dysfunction appears to be linked to development of obesity and type 2 diabetes and correction of steroid abnormalities may offer new approaches to therapy. We therefore analyzed plasma steroids in 15-16 week old obese and diabetic db/db mice using liquid chromatography-tandem mass spectrometry. Lean db/+ served as controls. Db/db mice developed obesity, hyperglycemia, hyperleptinemia, and hyperlipidemia. Hepatic triglyceride storage was increased and adiponectin and pancreatic insulin were lowered. Aldosterone, corticosterone, 11-deoxycorticosterone, and progesterone were respectively increased by 3.6-, 2.9-, 3.4, and 1.7-fold in db/db mice compared to controls. Ratios of aldosterone-to-progesterone and corticosterone-to-progesterone were respectively 2.0- and 1.5-fold higher in db/db mice. Genes associated with steroidogenesis were quantified in the adrenal glands and gonadal adipose tissues. In adrenals, Cyp11b2 , Cyp11b1 , Cyp21a1 , Hsd3b1 , Cyp11a1 , and StAR were all significantly increased in db/db mice compared with db/+ controls. In adipose tissue, no Cyp11b2 or Cyp11b1 transcripts were detected and no differences in Cyp21a1 , Hsd3b1 , Cyp11a1 , or StAR expression were found between db/+ and db/db mice. In conclusion, the present study showed an elevated steroid hormone production and adrenal steroidogenesis in the db/db model of obesity and type 2 diabetes. © Georg Thieme Verlag KG Stuttgart · New York.
Mirza, Muzna; Brown, Todd B; Saini, Devashish; Pepper, Tracy L; Nandigam, Hari Krishna; Kaza, Niroop; Cofield, Stacey S
2008-10-01
Cardiopulmonary resuscitation (CPR) with adequate chest compression depth appears to improve first shock success in cardiac arrest. We evaluate the effect of simplification of chest compression instructions on compression depth in dispatcher-assisted CPR protocol. Data from two randomized, double-blinded, controlled trials with identical methodology were combined to obtain 332 records for this analysis. Subjects were randomized to either modified Medical Priority Dispatch System (MPDS) v11.2 protocol or a new simplified protocol. The main difference between the protocols was the instruction to "push as hard as you can" in the simplified protocol, compared to "push down firmly 2in. (5cm)" in MPDS. Data were recorded via a Laerdal ResusciAnne SkillReporter manikin. Primary outcome measures included: chest compression depth, proportion of compressions without error, with adequate depth and with total release. Instructions to "push as hard as you can", compared to "push down firmly 2in. (5cm)", resulted in improved chest compression depth (36.4 mm vs. 29.7 mm, p<0.0001), and improved median proportion of chest compressions done to the correct depth (32% vs. <1%, p<0.0001). No significant difference in median proportion of compressions with total release (100% for both) and average compression rate (99.7 min(-1) vs. 97.5 min(-1), p<0.56) was found. Modifying dispatcher-assisted CPR instructions by changing "push down firmly 2in. (5cm)" to "push as hard as you can" achieved improvement in chest compression depth at no cost to total release or average chest compression rate.
Implementing and diagnosing magnetic flux compression on the Z pulsed power accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
McBride, Ryan D.; Bliss, David E.; Gomez, Matthew R.
2015-11-01
We report on the progress made to date for a Laboratory Directed Research and Development (LDRD) project aimed at diagnosing magnetic flux compression on the Z pulsed-power accelerator (0-20 MA in 100 ns). Each experiment consisted of an initially solid Be or Al liner (cylindrical tube), which was imploded using the Z accelerator's drive current (0-20 MA in 100 ns). The imploding liner compresses a 10-T axial seed field, B z ( 0 ) , supplied by an independently driven Helmholtz coil pair. Assuming perfect flux conservation, the axial field amplification should be well described by B z ( tmore » ) = B z ( 0 ) x [ R ( 0 ) / R ( t )] 2 , where R is the liner's inner surface radius. With perfect flux conservation, B z ( t ) and dB z / dt values exceeding 10 4 T and 10 12 T/s, respectively, are expected. These large values, the diminishing liner volume, and the harsh environment on Z, make it particularly challenging to measure these fields. We report on our latest efforts to do so using three primary techniques: (1) micro B-dot probes to measure the fringe fields associated with flux compression, (2) streaked visible Zeeman absorption spectroscopy, and (3) fiber-based Faraday rotation. We also mention two new techniques that make use of the neutron diagnostics suite on Z. These techniques were not developed under this LDRD, but they could influence how we prioritize our efforts to diagnose magnetic flux compression on Z in the future. The first technique is based on the yield ratio of secondary DT to primary DD reactions. The second technique makes use of the secondary DT neutron time-of-flight energy spectra. Both of these techniques have been used successfully to infer the degree of magnetization at stagnation in fully integrated Magnetized Liner Inertial Fusion (MagLIF) experiments on Z [P. F. Schmit et al. , Phys. Rev. Lett. 113 , 155004 (2014); P. F. Knapp et al. , Phys. Plasmas, 22 , 056312 (2015)]. Finally, we present some recent developments for designing and fabricating novel micro B-dot probes to measure B z ( t ) inside of an imploding liner. In one approach, the micro B-dot loops were fabricated on a printed circuit board (PCB). The PCB was then soldered to off-the-shelf 0.020- inch-diameter semi-rigid coaxial cables, which were terminated with standard SMA connectors. These probes were recently tested using the COBRA pulsed power generator (0-1 MA in 100 ns) at Cornell University. In another approach, we are planning to use new multi-material 3D printing capabilities to fabricate novel micro B-dot packages. In the near future, we plan to 3D print these probes and then test them on the COBRA generator. With successful operation demonstrated at 1-MA, we will then make plans to use these probes on a 20-MA Z experiment.« less
Nishiyama, Chika; Iwami, Taku; Kitamura, Tetsuhisa; Ando, Masahiko; Sakamoto, Tetsuya; Marukawa, Seishiro; Kawamura, Takashi
2014-01-01
It is unclear how much the length of a cardiopulmonary resuscitation (CPR) training program can be reduced without ruining its effectiveness. The authors aimed to compare CPR skills 6 months and 1 year after training between shortened chest compression-only CPR training and conventional CPR training. Participants were randomly assigned to either the compression-only CPR group, which underwent a 45-minute training program consisting of chest compressions and automated external defibrillator (AED) use with personal training manikins, or the conventional CPR group, which underwent a 180-minute training program with chest compressions, rescue breathing, and AED use. Participants' resuscitation skills were evaluated 6 months and 1 year after the training. The primary outcome measure was the proportion of appropriate chest compressions 1 year after the training. A total of 146 persons were enrolled, and 63 (87.5%) in the compression-only CPR group and 56 (75.7%) in the conventional CPR group completed the 1-year evaluation. The compression-only CPR group was superior to the conventional CPR group regarding the proportion of appropriate chest compression (mean ± SD = 59.8% ± 40.0% vs. 46.3% ± 28.6%; p = 0.036) and the number of appropriate chest compressions (mean ± SD = 119.5 ± 80.0 vs. 77.2 ± 47.8; p = 0.001). Time without chest compression in the compression-only CPR group was significantly shorter than that in the conventional CPR group (mean ± SD = 11.8 ± 21.1 seconds vs. 52.9 ± 14.9 seconds; p < 0.001). The shortened compression-only CPR training program appears to help the general public retain CPR skills better than the conventional CPR training program. UMIN-CTR UMIN000001675. © 2013 by the Society for Academic Emergency Medicine.
NASA Astrophysics Data System (ADS)
Calabretta, N.; Cooman, I. A.; Stabile, R.
2018-04-01
We propose for the first time a coupling device concept for passive low-loss optical coupling, which is compatible with the ‘generic’ indium phosphide (InP) multi-project-wafer manufacturing. A low-to-high vertical refractive index contrast transition InP waveguide is designed and tapered down to adiabatically couple light into a top polymer waveguide. The on-chip embedded polymer waveguide is engineered at the chip facets for offering refractive-index and spot-size-matching to silica fiber-arrays. Numerical analysis shows that coupling losses lower than 1.5 dB can be achieved for a TE-polarized light between the InP waveguide and the on-chip embedded polymer waveguide at 1550 nm wavelength. The performance is mainly limited by the difficulty to control single-mode operation. However, coupling losses lower than 1.9 dB can be achieved for a bandwidth as large as 200 nm. Moreover, the foreseen fabrication process steps are indicated, which are compatible with the ‘generic’ InP multi-project-wafer manufacturing. A fabrication error tolerance study is performed, indicating that fabrication errors occur only in 0.25 dB worst case excess losses, as long as high precision lithography is used. The obtained results are promising and may open the route to large port counts and cheap packaging of InP-based photonic integrated chips.
NASA Astrophysics Data System (ADS)
Yao, Kai; Wu, Xueyan; An, Zhentao
2017-01-01
A flexible shielding fabric with dense uniform coating was prepared after electrical deposition of amorphous Ni-Fe-P and Ni-P alloy on copper-coated polyethylene terephthalate (PET) fabric. The effects of coating composition and the deposition rate were discussed by the current density, temperature and pH value. The morphology, composition, and structure of coating were analyzed by SEM, EDS, and XRD characterizations. The EMI shielding effectiveness and corrosion resistance were also tested. The results fabric possesses dense, smooth, and uniform coating, when the processing conditions are 60°C, pH=1.5, and current density =8.7A/dm2. The coating fabric consists of amorphous Ni-Fe-P alloy with 16.62% P (weight percent), which has excellent of corrosion resistance. By contrast the EMI shielding effectiveness of amorphous Ni-Fe-P was better than amorphous Ni-P. The EMI shielding effectiveness of this coated fabric achieves 69.20dB-80.30dB in a broad frequency range between 300 kHz˜1.5 GHz.
Farrell, L J; Lo, R; Wanford, J J; Jenkins, A; Maxwell, A; Piddock, L J V
2018-06-11
The current state of antibiotic discovery, research and development is insufficient to respond to the need for new treatments for drug-resistant bacterial infections. The process has changed over the last decade, with most new agents that are in Phases 1-3, or recently approved, having been discovered in small- and medium-sized enterprises or academia. These agents have then been licensed or sold to large companies for further development with the goal of taking them to market. However, early drug discovery and development, including the possibility of developing previously discontinued agents, would benefit from a database of antibacterial compounds for scrutiny by the developers. This article describes the first free, open-access searchable database of antibacterial compounds, including discontinued agents, drugs under pre-clinical development and those in clinical trials: AntibioticDB (AntibioticDB.com). Data were obtained from publicly available sources. This article summarizes the compounds and drugs in AntibioticDB, including their drug class, mode of action, development status and propensity to select drug-resistant bacteria. AntibioticDB includes compounds currently in pre-clinical development and 834 that have been discontinued and that reached varying stages of development. These may serve as starting points for future research and development.
el-Briak, Hasna; Durand, Denis; Nurit, Josiane; Munier, Sylvie; Pauvert, Bernard; Boudeville, Phillipe
2002-01-01
By mixing CaHPO(4) x 2H(2)O (DCPD) and CaO with water or sodium phosphate buffers as liquid phase, a calcium phosphate cement was obtained. Its physical and mechanical properties, such as compressive strength, initial and final setting times, cohesion time, dough time, swelling time, dimensional and thermal behavior, and injectability were investigated by varying different parameters such as liquid to powder (L/P) ratio (0.35-0.7 ml g(-1)), molar calcium to phosphate (Ca/P) ratio (1.67-2.5) and the pH (4, 7, and 9) and the concentration (0-1 M) of the sodium phosphate buffer. The best results were obtained with the pH 7 sodium phosphate buffer at the concentration of 0.75 M. With this liquid phase, physical and mechanical properties depended on the Ca/P and L/P ratios, varying from 3 to 11 MPa (compressive strength), 6 to 10 min (initial setting time), 11 to 15 min (final setting time), 15 to 30 min (swelling time), 7 to 20 min (time of 100% injectability). The dough or working time was over 16 min. This cement expanded during its setting (1.2-5 % according to Ca/P and L/P ratios); this would allow a tight filling. Given the mechanical and rheological properties of this new DCPD/CaO-based cement, its use as root canal sealing material can be considered as classical calcium hydroxide or ZnO/eugenol-based pastes, without or with a gutta-percha point. Copyright 2002 Wiley Periodicals, Inc. J Biomed Mater Res (Appl Biomater) 63: 447-453, 2002
Kim, Yeomyung
2017-01-01
Objective We developed a new chest compression depth (CCD) measuring technology using radar and impulse-radio ultra-wideband (IR-UWB) sensor. This study was performed to determine its accuracy on a soft surface. Methods Four trials, trial 1: chest compressions on the floor using an accelerometer device; trial 2: chest compressions on the floor using an IR-UWB sensor; trial 3: chest compressions on a foam mattress using an accelerometer device; trial 4: chest compressions on a foam mattress using an IR-UWB sensor, were performed in a random order. In all the trials, a cardiopulmonary resuscitation provider delivered 50 uninterrupted chest compressions to a manikin. Results The CCD measured by the manikin and the device were as follows: 57.42 ± 2.23 and 53.92 ± 2.92 mm, respectively in trial 1 (p < 0.001); 56.29 ± 1.96 and 54.16 ± 3.90 mm, respectively in trial 2 (p < 0.001); 55.61 ± 1.57 and 103.48 ± 10.48 mm, respectively in trial 3 (p < 0.001); 57.14 ± 3.99 and 55.51 ± 3.39 mm, respectively in trial 4 (p = 0.012). The gaps between the CCD measured by the manikin and the devices (accelerometer device vs. IR-UWB sensor) on the floor were not different (3.50 ± 2.08 mm vs. 3.15 ± 2.27 mm, respectively, p = 0.136). However, the gaps were significantly different on the foam mattress (48.53 ± 5.65 mm vs. 4.10 ± 2.47 mm, p < 0.001). Conclusion The IR-UWB sensor could measure the CCD accurately both on the floor and on the foam mattress. PMID:28854262
Yu, Byung Gyu; Oh, Je Hyeok; Kim, Yeomyung; Kim, Tae Wook
2017-01-01
We developed a new chest compression depth (CCD) measuring technology using radar and impulse-radio ultra-wideband (IR-UWB) sensor. This study was performed to determine its accuracy on a soft surface. Four trials, trial 1: chest compressions on the floor using an accelerometer device; trial 2: chest compressions on the floor using an IR-UWB sensor; trial 3: chest compressions on a foam mattress using an accelerometer device; trial 4: chest compressions on a foam mattress using an IR-UWB sensor, were performed in a random order. In all the trials, a cardiopulmonary resuscitation provider delivered 50 uninterrupted chest compressions to a manikin. The CCD measured by the manikin and the device were as follows: 57.42 ± 2.23 and 53.92 ± 2.92 mm, respectively in trial 1 (p < 0.001); 56.29 ± 1.96 and 54.16 ± 3.90 mm, respectively in trial 2 (p < 0.001); 55.61 ± 1.57 and 103.48 ± 10.48 mm, respectively in trial 3 (p < 0.001); 57.14 ± 3.99 and 55.51 ± 3.39 mm, respectively in trial 4 (p = 0.012). The gaps between the CCD measured by the manikin and the devices (accelerometer device vs. IR-UWB sensor) on the floor were not different (3.50 ± 2.08 mm vs. 3.15 ± 2.27 mm, respectively, p = 0.136). However, the gaps were significantly different on the foam mattress (48.53 ± 5.65 mm vs. 4.10 ± 2.47 mm, p < 0.001). The IR-UWB sensor could measure the CCD accurately both on the floor and on the foam mattress.
Gender differences in ozone-induced pulmonary and metabolic health effects
SOT 2015 abstractGender differences in ozone-induced pulmonary and metabolic health effectsU.P. Kodavanti1, V.L. Bass2, M.C. Schladweiler1, C.J. Gordon3, K.A. Jarema3, P. Phillips3, A.D. Ledbetter1, D.B. Miller4, S. Snow5, J.E. Richards1. 1 EPHD, NHEERL, USEPA, Research Triangle ...
Tibiotalocalcaneal Arthrodesis Nails: A Comparison of Nails With and Without Internal Compression.
Taylor, James; Lucas, Douglas E; Riley, Aimee; Simpson, G Alex; Philbin, Terrence M
2016-03-01
Hindfoot arthrodesis with tibiotalocalcaneal (TTC) intramedullary nails is used commonly when treating ankle and subtalar arthritis and other hindfoot pathology. Adequate compression is paramount to avoid nonunion and fatigue fracture of the hardware. Arthrodesis systems with internal compression have demonstrated superior compression to systems relying on external methods. This study examined the speed of union with TTC fusion nails with internal compression over nails without internal compression. A retrospective review was performed identifying nail type and time to union of the subtalar joint (STJ) and tibiotalar joint (TTJ). A total of 198 patients were included from 2003 to 2011. The median time to STJ fusion without internal compression was 104 days compared to 92 days with internal compression (P = .044). The median time to TTJ fusion without internal compression was 111 days compared to 93 days with internal compression (P = .010). Adjusting for diabetes, there was no significant difference in fusion speed with or without internal compression for the STJ (P = .561) or TTJ (P = .358). Nonunion rates were 24.5% for the STJ and 17.0% for the TTJ with internal compression, and 43.4% for the STJ and 42.1% for the TTJ without internal compression. This difference remained statistically significant after adjusting for diabetes for the TTJ (P = .001) but not for the STJ (P = .194). The intramedullary hindfoot arthrodesis nail was a viable treatment option in degenerative joint disease of the TTC joint. There appeared to be an advantage using systems with internal compression; however, there was no statistically significant difference after controlling for diabetes. Level III, retrospective comparative series. © The Author(s) 2015.
Function representation with circle inversion map systems
NASA Astrophysics Data System (ADS)
Boreland, Bryson; Kunze, Herb
2017-01-01
The fractals literature develops the now well-known concept of local iterated function systems (using affine maps) with grey-level maps (LIFSM) as an approach to function representation in terms of the associated fixed point of the so-called fractal transform. While originally explored as a method to achieve signal (and 2-D image) compression, more recent work has explored various aspects of signal and image processing using this machinery. In this paper, we develop a similar framework for function representation using circle inversion map systems. Given a circle C with centre õ and radius r, inversion with respect to C transforms the point p˜ to the point p˜', such that p˜ and p˜' lie on the same radial half-line from õ and d(õ, p˜)d(õ, p˜') = r2, where d is Euclidean distance. We demonstrate the results with an example.
Martin, B A; Sigal, A; Kurtzberg, D; Stapells, D R
1997-03-01
This study investigated the effects of decreased audibility produced by high-pass noise masking on cortical event-related potentials (ERPs) N1, N2, and P3 to the speech sounds /ba/and/da/presented at 65 and 80 dB SPL. Normal-hearing subjects pressed a button in response to the deviant sound in an oddball paradigm. Broadband masking noise was presented at an intensity sufficient to completely mask the response to the 65-dB SPL speech sounds, and subsequently high-pass filtered at 4000, 2000, 1000, 500, and 250 Hz. With high-pass masking noise, pure-tone behavioral thresholds increased by an average of 38 dB at the high-pass cutoff and by 50 dB one octave above the cutoff frequency. Results show that as the cutoff frequency of the high-pass masker was lowered, ERP latencies to speech sounds increased and amplitudes decreased. The cutoff frequency where these changes first occurred and the rate of the change differed for N1 compared to N2, P3, and the behavioral measures. N1 showed gradual changes as the masker cutoff frequency was lowered. N2, P3, and behavioral measures showed marked changes below a masker cutoff of 2000 Hz. These results indicate that the decreased audibility resulting from the noise masking affects the various ERP components in a differential manner. N1 is related to the presence of audible stimulus energy, being present whether audible stimuli are discriminable or not. In contrast, N2 and P3 were absent when the stimuli were audible but not discriminable (i.e., when the second formant transitions were masked), reflecting stimulus discrimination. These data have implications regarding the effects of decreased audibility on cortical processing of speech sounds and for the study of cortical ERPs in populations with hearing impairment.
Li, Hua; Ji, Hyeon-Seon; Kang, Ji-Hyun; Shin, Dong-Ha; Park, Ho-Yong; Choi, Myung-Sook; Lee, Chul-Ho; Lee, In-Kyung; Yun, Bong-Sik; Jeong, Tae-Sook
2015-08-19
This study investigated the molecular mechanisms underlying the antidiabetic effect of an ethanol extract of soy leaves (ESL) in db/db mice. Control groups (db/+ and db/db) were fed a normal diet (ND), whereas the db/db-ESL group was fed ND with 1% ESL for 8 weeks. Dietary ESL improved glucose tolerance and lowered plasma glucose, glycated hemoglobin, HOMA-IR, and triglyceride levels. The pancreatic insulin content of the db/db-ESL group was significantly greater than that of the db/db group. ESL supplementation altered pancreatic IRS1, IRS2, Pdx1, Ngn3, Pax4, Ins1, Ins2, and FoxO1 expression. Furthermore, ESL suppressed lipid accumulation and increased glucokinase activity in the liver. ESL primarily contained kaempferol glycosides and pheophorbides. Kaempferol, an aglycone of kaempferol glycosides, improved β-cell proliferation through IRS2-related FoxO1 signaling, whereas pheophorbide a, a product of chlorophyll breakdown, improved insulin secretion and β-cell proliferation through IRS1-related signaling with protein kinase A in MIN6 cells. ESL effectively regulates glucose homeostasis by enhancing IRS-mediated β-cell insulin signaling and suppressing SREBP-1-mediated hepatic lipid accumulation in db/db mice.
Romero, Matthew A.; Osburn, Shelby C.; Mobley, Christopher B.; Anderson, Richard G.; Goodlett, Michael D.; Pascoe, David D.
2017-01-01
Purpose We sought to compare the effects of external pneumatic compression (EPC) and sham when used concurrently with resistance training on performance-related outcomes and molecular measures related to recovery. Methods Twenty (N = 20) resistance-trained male participants (aged 21.6±2.4 years) were randomized to balanced sham or EPC intervention groups. The protocol consisted of 3 consecutive days of heavy, voluminous back squat exercise followed by EPC/sham treatment (Days2-4) and 3 consecutive days of recovery (Days5-7) with EPC/sham only on Days5-6. On Day1 (PRE), and Days3-7, venipuncture, flexibility and pressure-to-pain threshold (PPT) measures were performed. Vastsus lateralis muscle tissue was biopsied at PRE, 1-h post-EPC/sham treatment on Day2 (POST1) and 24-h post-EPC/sham treatment on Day7 (POST2). Isokinetic peak torque was assessed at PRE and POST2. Results Peak isokinetic strength did not change from PRE to POST2 in either group. The PPT was significantly lower on Days3-6 with sham, indicating greater muscle soreness, though this was largely abolished in the EPC group. A significant decrease in flexibility with sham was observed on Day3 (+16.2±4.6% knee joint angle; P<0.01) whereas there was no change with EPC (+2.8±3.8%; P>0.01). Vastus lateralis poly-ubiquitinated proteins significantly increased at the POST2 time point relative to PRE with sham (+66.6±24.6%; P<0.025) and were significantly greater (P<0.025) than those observed with EPC at the same time point (-18.6±8.5%). 4-hydroxynonenal values were significantly lower at POST2 relative to PRE with EPC (-16.2±5.6%; P<0.025) and were significantly lower (P<0.025) than those observed with sham at the same time point (+11.8±5.9%). Conclusion EPC mitigated a reduction in flexibility and PPT that occurred with sham. Moreover, EPC reduced select skeletal muscle oxidative stress and proteolysis markers during recovery from heavy resistance exercise. PMID:28662152
Polycyclic aromatic hydrocarbons (PAHs ) are ubiquitous environmental pollutants. Due to its structural similarity with the potent carcinogen dibenzo[a,l]pyrene (DB[a,l]P) and because of its environmental presence naphtho[1,2- a]pyrene (N[1,2-a]P) is of considerable resea...
NASA Astrophysics Data System (ADS)
Park, J. H.; Chi, H. C.; Lim, I. S.; Seong, Y. J.; Pak, J.
2017-12-01
During the first phase of EEW(Earthquake Early Warning) service to the public by KMA (Korea Meteorological Administration) from 2015 in Korea, KIGAM(Korea Institute of Geoscience and Mineral Resources) has adopted ElarmS2 of UC Berkeley BSL and modified local magnitude relation, travel time curves and association procedures so called TrigDB back-filling method. The TrigDB back-filling method uses a database of sorted lists of stations based on epicentral distances of the pre-defined events located on the grids for 1,401 × 1,601 = 2,243,001 events around the Korean Peninsula at a grid spacing of 0.05 degrees. When the version of an event is updated, the TrigDB back-filling method is invoked. First, the grid closest to the epicenter of an event is chosen from the database and candidate stations, which are stations corresponding to the chosen grid and also adjacent to the already-associated stations, are selected. Second, the directions from the chosen grid to the associated stations are averaged to represent the direction of wave propagation, which is used as a reference for computing apparent travel times. The apparent travel times for the associated stations are computed using a P wave velocity of 5.5 km/s from the grid to the projected points in the reference direction. The travel times for the triggered candidate stations are also computed and used to obtain the difference between the apparent travel times of the associated stations and the triggered candidates. Finally, if the difference in the apparent travel times is less than that of the arrival times, the method forces the triggered candidate station to be associated with the event and updates the event location. This method is useful to reduce false locations of events which could be generated from the deep (> 500 km) and regional distance earthquakes happening on the subduction pacific plate boundaries. In comparison of the case study between TrigDB back-filling applied system and the others, we could get the more reliable results in the early stagy of the version updating by forced association of the neighbored stations.
Performance comparison of leading image codecs: H.264/AVC Intra, JPEG2000, and Microsoft HD Photo
NASA Astrophysics Data System (ADS)
Tran, Trac D.; Liu, Lijie; Topiwala, Pankaj
2007-09-01
This paper provides a detailed rate-distortion performance comparison between JPEG2000, Microsoft HD Photo, and H.264/AVC High Profile 4:4:4 I-frame coding for high-resolution still images and high-definition (HD) 1080p video sequences. This work is an extension to our previous comparative study published in previous SPIE conferences [1, 2]. Here we further optimize all three codecs for compression performance. Coding simulations are performed on a set of large-format color images captured from mainstream digital cameras and 1080p HD video sequences commonly used for H.264/AVC standardization work. Overall, our experimental results show that all three codecs offer very similar coding performances at the high-quality, high-resolution setting. Differences tend to be data-dependent: JPEG2000 with the wavelet technology tends to be the best performer with smooth spatial data; H.264/AVC High-Profile with advanced spatial prediction modes tends to cope best with more complex visual content; Microsoft HD Photo tends to be the most consistent across the board. For the still-image data sets, JPEG2000 offers the best R-D performance gains (around 0.2 to 1 dB in peak signal-to-noise ratio) over H.264/AVC High-Profile intra coding and Microsoft HD Photo. For the 1080p video data set, all three codecs offer very similar coding performance. As in [1, 2], neither do we consider scalability nor complexity in this study (JPEG2000 is operating in non-scalable, but optimal performance mode).
Seidler, Andreas; Wagner, Mandy; Schubert, Melanie; Dröge, Patrik; Römer, Karin; Pons-Kühnemann, Jörn; Swart, Enno; Zeeb, Hajo; Hegewald, Janice
2016-11-01
Several studies point to an elevated risk for cardiovascular diseases induced by traffic noise. We examined the association between aircraft, road traffic and railway noise and heart failure or hypertensive heart disease (HHD) in a large case-control study. The study population consisted of individuals that were insured by three large statutory health insurance funds in the Rhine-Main area of Germany. Based on insurance claims and prescription data, 104,145 cases of heart failure or HHD diagnosed 2006-10 were identified and compared with 654,172 control subjects. Address-specific exposure to aircraft, road and railway traffic noise in 2005 was estimated. Odds Ratios were calculated using logistic regression analysis, adjusted for age, sex, local proportion of persons receiving unemployment benefits, and individual socioeconomic status (available for 39% of the individuals). A statistically significant linear exposure-risk relationship with heart failure or hypertensive heart disease was found for aircraft traffic noise (1.6% risk increase per 10dB increase in the 24-h continuous noise level; 95% CI 0.3-3.0%), road traffic noise (2.4% per 10dB; 95% CI 1.6-3.2%), and railway noise (3.1% per 10dB; 95% CI 2.2-4.1%). For individuals with 24-h continuous aircraft noise levels <40dB and nightly maximum aircraft noise levels exceeding 50dB six or more times, a significantly increased risk was observed. In general, risks of HHD were considerably higher than the risks of heart failure. Regarding the high prevalence of traffic noise from various sources, even low risk increases for frequent diseases are relevant for the population as a whole. Copyright © 2016 Elsevier GmbH. All rights reserved.
Design of a Dual Waveguide Normal Incidence Tube (DWNIT) Utilizing Energy and Modal Methods
NASA Technical Reports Server (NTRS)
Betts, Juan F.; Jones, Michael G. (Technical Monitor)
2002-01-01
This report investigates the partition design of the proposed Dual Waveguide Normal Incidence Tube (DWNIT). Some advantages provided by the DWNIT are (1) Assessment of coupling relationships between resonators in close proximity, (2) Evaluation of "smart liners", (3) Experimental validation for parallel element models, and (4) Investigation of effects of simulated angles of incidence of acoustic waves. Energy models of the two chambers were developed to determine the Sound Pressure Level (SPL) drop across the two chambers, through the use of an intensity transmission function for the chamber's partition. The models allowed the chamber's lengthwise end samples to vary. The initial partition design (2" high, 16" long, 0.25" thick) was predicted to provide at least 160 dB SPL drop across the partition with a compressive model, and at least 240 dB SPL drop with a bending model using a damping loss factor of 0.01. The end chamber sample transmissions coefficients were set to 0.1. Since these results predicted more SPL drop than required, a plate thickness optimization algorithm was developed. The results of the algorithm routine indicated that a plate with the same height and length, but with a thickness of 0.1" and 0.05 structural damping loss, would provide an adequate SPL isolation between the chambers.
Transmitter pointing loss calculation for free-space optical communications link analyses
NASA Technical Reports Server (NTRS)
Marshall, William K.
1987-01-01
In calculating the performance of free-space optical communications links, the transmitter pointing loss is one of the two most important factors. It is shown in this paper that the traditional formula for the instantaneous pointing loss (i.e., for the transmitter telescope far-field beam pattern) is quite inaccurate. A more accurate and practical approximation is developed in which the pointing loss is calculated using a Taylor series approximation. The four-term series is shown to be accurate to 0.1 dB for the theta angles not greater than 0.9 lambda/D (wavelength/telescope diameter).
Jansen, Jesse; McCaffery, Kirsten J; Hayen, Andrew; Ma, David; Reddel, Helen K
2012-03-01
Variation in graphic format can substantially influence interpretation of data. Despite a large body of literature on the optimal design of graphs, little attention has been paid to the format of charts for health monitoring. This study assessed the effect of aspect ratio (x:y ratio) and interconnecting lines on visual identification of change in biological data, such as during asthma exacerbations. Eighty volunteers viewed 72 sets of six consecutive blocks of unidentified biological data, recording if each block of data was increasing, decreasing, or the same as the previous block. Three chart aspect ratios were examined (A, 5.2:1; B, 3.0:1; C, 1.1:1), with or without lines between data points. Datasets from lung function monitoring by asthma patients included a mild/moderate/severe fall ('exacerbation') or no exacerbation. False negative (missing true exacerbations) and false positive (identifying non-existent exacerbations) responses were calculated. 84% of exacerbation blocks were correctly identified. There was a significant interaction between exacerbation severity and aspect ratio (p=0.0048). The most compressed chart (C) had the fewest false negative responses. Moderate falls were missed in 24%, 12%, and 5% of trials on charts A, B, and C, respectively (C vs A: adjusted relative risk 0.19 (95% CI 0.12 to 0.30)). False positive responses were infrequent (A, 2.5%; B, 3.8%; C, 8.3%), increasing slightly if data points were joined with lines (4.3% vs 5.1%, p=0.004) . Compressed charts can improve the visual detection of change in biological data by up to 80%. The aspect ratio of charts should be standardised to facilitate clinical pattern recognition.
Cachia, Victor V; Culbert, Brad; Warren, Chris; Oka, Richard; Mahar, Andrew
2003-01-01
The purpose of this study was to evaluate the structural and mechanical characteristics of a new and unique titanium cortical-cancellous helical compression anchor with BONE-LOK (Triage Medical, Inc., Irvine, CA) technology for compressive internal fixation of fractures and osteotomies. This device provides fixation through the use of a distal helical anchor and a proximal retentive collar that are united by an axially movable pin (U.S. and international patents issued and pending). The helical compression anchor (2.7-mm diameter) was compared with 3.0-mm diameter titanium cancellous screws (Synthes, Paoli, PA) for pullout strength and compression in 7# and 12# synthetic rigid polyurethane foam (simulated bone matrix), and for 3-point bending stiffness. The following results (mean +/- standard deviation) were obtained: foam block pullout strength in 12# foam: 2.7-mm helical compression anchor 70 +/- 2.0 N and 3.0-mm titanium cancellous screws 37 +/- 11 N; in 7# foam: 2.7-mm helical compression anchor 33 +/- 3 N and 3.0-mm titanium cancellous screws 31 +/- 12 N. Three-point bending stiffness, 2.7-mm helical compression anchor 988 +/- 68 N/mm and 3.0-mm titanium cancellous screws 845 +/- 88 N/mm. Compression strength testing in 12# foam: 2.7-mm helical compression anchor 70.8 +/- 4.8 N and 3.0-mm titanium cancellous screws 23.0 +/- 3.1 N, in 7# foam: 2.7-mm helical compression anchor 42.6 +/- 3.2 N and 3.0-mm titanium cancellous screws 10.4 +/- 0.9 N. Results showed greater pullout strength, 3-point bending stiffness, and compression strength for the 2.7-mm helical compression anchor as compared with the 3.0-mm titanium cancellous screws in these testing models. This difference represents a distinct advantage in the new device that warrants further in vivo testing.
The magnitude of tissue cooling during cryotherapy with varied types of compression.
Tomchuk, David; Rubley, Mack D; Holcomb, William R; Guadagnoli, Mark; Tarno, Jason M
2010-01-01
Certified athletic trainers can choose different types of external compression (none, Flex-i-Wrap, and elastic wrap) when applying an ice bag to the body. However, which type facilitates the greatest magnitude of tissue cooling is unclear. To compare the effects of 2 common types of external compression on the magnitude of surface and intramuscular cooling during an ice-bag treatment. Randomized controlled trial. University research laboratory. Fourteen college students (10 women, 4 men; age = 22.4 +/- 1.8 years, height = 169.1 +/- 8.2 cm, mass = 73.3 +/- 18.5 kg, skinfold = 13.14 +/- 1.61 mm) with previous cryotherapy experience and a posterior lower leg skinfold equal to or less than 15 mm. On 3 different days separated by 24 to 48 hours, an ice bag was applied to the posterior lower leg surface of each participant for 30 minutes with no compression, with elastic wrap, or with Flex-i-Wrap. Posterior lower leg surface and intramuscular (2 cm) temperatures were recorded for 95 minutes. At 15 minutes, the elastic wrap produced greater surface temperature reduction than no compression (P = .03); this difference remained throughout the protocol (P range, .03 to .04). At 30 minutes, surface temperatures were 14.95 degrees C, 11.55 degrees C, and 9.49 degrees C when an ice bag was applied with no external compression, Flex-i-Wrap, and elastic wrap, respectively. Surface temperatures between Flex-i-Wrap and elastic wrap and between Flex-i-Wrap and no compression were never different. At 10 minutes, Flex-i-Wrap (P = .006) and elastic wrap (P < .001) produced greater intramuscular temperature reduction than no compression produced; these differences remained throughout the protocol. At 10 minutes, no compression, Flex-i-Wrap, and elastic wrap decreased intramuscular temperature by 1.34 degrees C, 2.46 degrees C, and 2.73 degrees C, respectively. At 25 minutes, elastic wrap (8.03 degrees C) produced greater temperature reduction than Flex-i-Wrap (6.65 degrees C) (P = .03) or no compression (4.63 degrees C) (P < .001 ). These differences remained throughout ice application and until 50 minutes after ice-bag removal. During an ice-bag application, external compression with elastic wrap was more effective than Flex-i-Wrap at reducing intramuscular tissue temperature. Elastic wraps should be used for acute injury care.
Marchianti, Ancah Caesarina Novi; Arimura, Emi; Ushikai, Miharu; Horiuchi, Masahisa
2014-09-01
Exercise is effective for preventing the onset and development of type 2 diabetes mellitus (T2DM) in human cases; however, the effect of exercise on the pathophysiology using animal models of T2DM has not been fully evaluated. We applied voluntary exercise under pair-fed (P) conditions in db mice, an animal model of T2DM. Exercising (Ex) and sedentary (Se) mice were placed in a cage, equipped with a free or locked running wheel, for 4 weeks, respectively. The amount of food consumed by ad libitum-fed wild-type mice under the Se condition (ad-WT) was supplied to all mice, except ad libitum db mice (ad-db). Blood parameters and expression of the genes involved in nutrient metabolism were analyzed. PEx-db (pair-fed and exercising) mice showed significantly lower HbA1c, body weight and liver weight than PSe-db and ad-db mice. Decreased hepatic triglycerides in PEx-db mice corresponded to a lower expression of lipogenic enzyme genes in the liver. Moreover, PEx-db mice showed significantly lower plasma branched-chain amino acids (BCAA), arginine, proline, and tyrosine, in addition to increased skeletal muscle (SM) weight, than PSe-db and ad-db mice, in spite of little influence on the expression of the BCAA transaminase gene, in SM and WAT. We found that exercise under a food restriction condition decreases several amino acids, including BCAA, and may improve insulin sensitivity more than mere food restriction. We propose that the decreased concentration of blood amino acids may be a valuable marker evaluating the effects of exercise on diabetic conditions.
Sex differences in diet and inhaled ozone (O3) induced metabolic impairment
APS 2015 abstract Sex differences in diet and inhaled ozone (O3) induced metabolic impairment U.P. Kodavanti1, V.L. Bass2, M.C. Schladweiler1, C.J. Gordon3, K.A. Jarema1, P. Phillips1, A.D. Ledbetter1, D.B. Miller4, S. Snow5, J.E. Richards1. 1 EPHD, NHEERL, USEPA, Research Triang...
Towards Probablistic Assessment of Hypobaric Decompression Sickness Treatment
NASA Technical Reports Server (NTRS)
Conkin, J.; Abercromby, A. F.; Feiveson, A. H.; Gernhardt, M. L.; Norcross, J. R.; Ploutz-Snyder, R.; Wessel, J. H., III
2013-01-01
INTRODUCTION: Pressure, oxygen (O2), and time are the pillars to effective treatment of decompression sickness (DCS). The NASA DCS Treatment Model links a decrease in computed bubble volume to the resolution of a symptom. The decrease in volume is realized in two stages: a) during the Boyle's Law compression and b) during subsequent dissolution of the gas phase by the O2 window. METHODS: The cumulative distribution of 154 symptoms that resolved during repressurization was described with a log-logistic density function of pressure difference (deltaP as psid) associated with symptom resolution and two other explanatory variables. The 154 symptoms originated from 119 cases of DCS during 969 exposures in 47 different altitude tests. RESULTS: The probability of symptom resolution [P(symptom resolution)] = 1 / (1+exp(- (ln(deltaP) - 1.682 + 1.089×AMB - 0.00395×SYMPTOM TIME) / 0.633)), where AMB is 1 when the subject ambulated as part of the altitude exposure or else 0 and SYMPTOM TIME is the elapsed time in min from start of the altitude exposure to recognition of a DCS symptom. The P(symptom resolution) was estimated from computed deltaP from the Tissue Bubble Dynamics Model based on the "effective" Boyle's Law change: P2 - P1 (deltaP, psid) = P1×V1/V2 - P1, where V1 is the computed volume of a spherical bubble in a unit volume of tissue at low pressure P1 and V2 is computed volume after a change to a higher pressure P2. V2 continues to decrease through time at P2, at a faster rate if 100% ground level O2 was breathed. The computed deltaP is the effective treatment pressure at any point in time as if the entire ?deltaP was just from Boyle's Law compression. DISCUSSION: Given the low probability of DCS during extravehicular activity and the prompt treatment of a symptom with options through the model it is likely that the symptom and gas phase will resolve with minimum resources and minimal impact on astronaut health, safety, and productivity.
Type 2 diabetes and hearing loss in personnel of the Self-Defense Forces.
Sakuta, Hidenari; Suzuki, Takashi; Yasuda, Hiroko; Ito, Teizo
2007-02-01
The association of type 2 diabetes with hearing loss was evaluated in middle-aged male personnel of the Self-Defense Forces (SDFs). Hearing loss was defined as the pure-tone average (PTA) of the thresholds frequency at 0.5, 1, 2, and 4 kHz greater than 25 dB hearing levels (HL) in the worse ear. Diabetes status was determined by self-report of physician-diagnosed diabetes or by oral glucose tolerance test (OGTT). Of 699 subjects studied (age 52.9+/-1.0 years), 103 subjects were classified as having type 2 diabetes. Fasting plasma glucose of diabetic subjects was 120+/-19 mg/dl. Hearing loss levels were (worse) higher among diabetic subjects compared with subjects with normal glucose tolerance (NGT) (30.7+/-13.0 dB versus 27.4+/-12.3 dB, P=0.014). Hearing loss was more prevalent among diabetic subjects than among subjects with normal glucose tolerance (60.2% versus 45.2%, P=0.006). The odds ratio (OR) of type 2 diabetes for the presence of hearing loss was 1.87 (95% confidence interval 1.20-2.91, P=0.006) in a logistic regression analysis adjusted for age, rank, cigarette smoking and ethanol consumption. These results suggest that type 2 diabetes is associated with hearing loss independently of lifestyle factors in middle-aged men.
Eliminating bias in rainfall estimates from microwave links due to antenna wetting
NASA Astrophysics Data System (ADS)
Fencl, Martin; Rieckermann, Jörg; Bareš, Vojtěch
2014-05-01
Commercial microwave links (MWLs) are point-to-point radio systems which are widely used in telecommunication systems. They operate at frequencies where the transmitted power is mainly disturbed by precipitation. Thus, signal attenuation from MWLs can be used to estimate path-averaged rain rates, which is conceptually very promising, since MWLs cover about 20 % of surface area. Unfortunately, MWL rainfall estimates are often positively biased due to additional attenuation caused by antenna wetting. To correct MWL observations a posteriori to reduce the wet antenna effect (WAE), both empirically and physically based models have been suggested. However, it is challenging to calibrate these models, because the wet antenna attenuation depends both on the MWL properties (frequency, type of antennas, shielding etc.) and different climatic factors (temperature, due point, wind velocity and direction, etc.). Instead, it seems straight forward to keep antennas dry by shielding them. In this investigation we compare the effectiveness of antenna shielding to model-based corrections to reduce the WAE. The experimental setup, located in Dübendorf-Switzerland, consisted of 1.85-km long commercial dual-polarization microwave link at 38 GHz and 5 optical disdrometers. The MWL was operated without shielding in the period from March to October 2011 and with shielding from October 2011 to July 2012. This unique experimental design made it possible to identify the attenuation due to antenna wetting, which can be computed as the difference between the measured and theoretical attenuation. The theoretical path-averaged attenuation was calculated from the path-averaged drop size distribution. During the unshielded periods, the total bias caused by WAE was 0.74 dB, which was reduced by shielding to 0.39 dB for the horizontal polarization (vertical: reduction from 0.96 dB to 0.44 dB). Interestingly, the model-based correction (Schleiss et al. 2013) was more effective because it reduced the bias of unshielded periods to 0.07 dB for the horizontal polarization (vertical: 0.06 dB). Applying the same model-based correction to shielded periods reduces the bias even more, to -0.03 dB and -0.01 dB, respectively. This indicates that additional attenuation could be caused also by different effects, such as reflection of sidelobes from wet surfaces and other environmental factors. Further, model-based corrections do not capture correctly the nature of WAE, but more likely provide only an empirical correction. This claim is supported by the fact that detailed analysis of particular events reveals that both antenna shielding and model-based correction performance differ substantially from event to event. Further investigation based on direct observation of antenna wetting and other environmental variables needs to be performed to identify more properly the nature of the attenuation bias. Schleiss, M., J. Rieckermann, and A. Berne, 2013: Quantification and modeling of wet-antenna attenuation for commercial microwave links. IEEE Geosci. Remote Sens. Lett., 10.1109/LGRS.2012.2236074.
Compression of facsimile graphics for transmission over digital mobile satellite circuits
NASA Astrophysics Data System (ADS)
Dimolitsas, Spiros; Corcoran, Frank L.
A technique for reducing the transmission requirements of facsimile images while maintaining high intelligibility in mobile communications environments is described. The algorithms developed are capable of achieving a compression of approximately 32 to 1. The technique focuses on the implementation of a low-cost interface unit suitable for facsimile communication between low-power mobile stations and fixed stations for both point-to-point and point-to-multipoint transmissions. This interface may be colocated with the transmitting facsimile terminals. The technique was implemented and tested by intercepting facsimile documents in a store-and-forward mode.
Chung, Kuo-Liang; Huang, Chi-Chao; Hsu, Tsu-Chun
2017-09-04
In this paper, we propose a novel adaptive chroma subsampling-binding and luma-guided (ASBLG) chroma reconstruction method for screen content images (SCIs). After receiving the decoded luma and subsampled chroma image from the decoder, a fast winner-first voting strategy is proposed to identify the used chroma subsampling scheme prior to compression. Then, the decoded luma image is subsampled as the identified subsampling scheme was performed on the chroma image such that we are able to conclude an accurate correlation between the subsampled decoded luma image and the decoded subsampled chroma image. Accordingly, an adaptive sliding window-based and luma-guided chroma reconstruction method is proposed. The related computational complexity analysis is also provided. We take two quality metrics, the color peak signal-to-noise ratio (CPSNR) of the reconstructed chroma images and SCIs and the gradient-based structure similarity index (CGSS) of the reconstructed SCIs to evaluate the quality performance. Let the proposed chroma reconstruction method be denoted as 'ASBLG'. Based on 26 typical test SCIs and 6 JCT-VC test screen content video sequences (SCVs), several experiments show that on average, the CPSNR gains of all the reconstructed UV images by 4:2:0(A)-ASBLG, SCIs by 4:2:0(MPEG-B)-ASBLG, and SCVs by 4:2:0(A)-ASBLG are 2.1 dB, 1.87 dB, and 1.87 dB, respectively, when compared with that of the other combinations. Specifically, in terms of CPSNR and CGSS, CSBILINEAR-ASBLG for the test SCIs and CSBICUBIC-ASBLG for the test SCVs outperform the existing state-of-the-art comparative combinations, where CSBILINEAR and CSBICUBIC denote the luma-aware based chroma subsampling schemes by Wang et al.
Anti-diabetic and hypolipidemic effects of Sargassum yezoense in db/db mice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Su-Nam, E-mail: snkim@kist.re.kr; Lee, Woojung; Bae, Gyu-Un
2012-08-10
Highlights: Black-Right-Pointing-Pointer Sargassum yezoense (SY) treatment improved glucose and lipid impairment in vivo. Black-Right-Pointing-Pointer This pharmacological action is associated with PPAR{alpha}/{gamma} dual activation. Black-Right-Pointing-Pointer It decreases the expression of G6Pase for gluconeogenesis in liver. Black-Right-Pointing-Pointer It increases the expression of UCP3 for lipid metabolism in adipose tissue. Black-Right-Pointing-Pointer There are no significant side effects such as body weight gain and hepatomegaly. -- Abstract: Peroxisome proliferator-activated receptors (PPARs) have been considered to be desirable targets for metabolic syndrome, even though their specific agonists have several side effects including body weight gain, edema and tissue failure. Previously, we have reported in vitromore » effects of Sargassum yezoense (SY) and its ingredients, sargaquinoic acid (SQA) and sargahydroquinoic acid (SHQA), on PPAR{alpha}/{gamma} dual transcriptional activation. In this study, we describe in vivo pharmacological property of SY on metabolic disorders. SY treatment significantly improved glucose and lipid impairment in db/db mice model. More importantly, there are no significant side effects such as body weight gain and hepatomegaly in SY-treated animals, indicating little side effects of SY in liver and lipid metabolism. In addition, SY led to a decrease in the expression of G6Pase for gluconeogenesis in liver responsible for lowering blood glucose level and an increase in the expression of UCP3 in adipose tissue for the reduction of total and LDL-cholesterol level. Altogether, our data suggest that SY would be a potential therapeutic agent against type 2 diabetes and related metabolic disorders by ameliorating the glucose and lipid metabolism.« less
Electronic structure in 1T-ZrS2 monolayer by strain
NASA Astrophysics Data System (ADS)
Xin, Qianqian; Zhao, Xu; Ma, Xu; Wu, Ninghua; Liu, Xiaomeng; Wei, Shuyi
2017-09-01
We report electronic structure of 1T-ZrS2 monolayer with biaxial strain from -10% to 15%, basing the first principles calculations. Our calculation results indicate that the band structure of ZrS2 monolayer was changed clearly. The location of conduction band minimum (CBM) and valence band maximum (VBM) changed with the variation of isotropic strain. At compressive strain, the location of CBM and VBM retains at M and Γ point, respectively. The band gap of ZrS2 monolayer decreases from 1.111 eV to 0 eV when compressive strain increases from 0% to -8%, which means that the ZrS2 monolayer turns to metal at -8% compressive strain. Under the tensile strain, the ZrS2 monolayer also retains be an indirect band gap semiconductor. The location of CBM moves from M to Γ point and the location of VBM moves along Γ-A-K-Γ direction. The band gap of ZrS2 monolayer firstly increases and then decreases and the biggest band gap is 1.577 eV at tensile strain 6%. We can see the compression strain is more effective than tensile strain in modulating band gap of 1T-ZrS2 monolayer.
Coletta, Alain; Molter, Colin; Duqué, Robin; Steenhoff, David; Taminau, Jonatan; de Schaetzen, Virginie; Meganck, Stijn; Lazar, Cosmin; Venet, David; Detours, Vincent; Nowé, Ann; Bersini, Hugues; Weiss Solís, David Y
2012-11-18
Genomics datasets are increasingly useful for gaining biomedical insights, with adoption in the clinic underway. However, multiple hurdles related to data management stand in the way of their efficient large-scale utilization. The solution proposed is a web-based data storage hub. Having clear focus, flexibility and adaptability, InSilico DB seamlessly connects genomics dataset repositories to state-of-the-art and free GUI and command-line data analysis tools. The InSilico DB platform is a powerful collaborative environment, with advanced capabilities for biocuration, dataset sharing, and dataset subsetting and combination. InSilico DB is available from https://insilicodb.org.
Does MAOA Increase Susceptibility to Prenatal Stress in Young Children?
Massey, Suena H.; Hatcher, Amalia E.; Clark, Caron A.C.; Burns, James L.; Pine, Daniel S.; Skol, Andrew D.; Mroczek, Daniel K.; Espy, Kimberly A.; Goldman, David; Cook, Edwin; Wakschlag, Lauren S.
2017-01-01
Background We previously demonstrated a gene-by-prenatal-environment interaction whereby the monoamine oxidase A gene (MAOA) modified the impact of prenatal tobacco exposure (PTE) on adolescent disruptive behavior (DB), with the MAOA risk genotype varying by sex. We extend this work by examining whether this mechanism is evident with another common adversity, prenatal stress exposure (PSE), and whether sex differences are present earlier in development in closer proximity to exposure. Methods Participants were 281 mothers and their 285 children derived from a prenatal cohort with in-depth prospective measures of PSE and PTE. We assessed DB at age 5 via dimensional developmentally-sensitive measurement. Analyses were stratified by sex based on prior evidence for sex differences. Results Concurrent stress exposure predicted DB in children (β=.310, p=.001), while main effects of prenatal exposures were seen only in boys. We found a three-way interaction of MAOAxPSExsex on DB (β=.813, p=.022). Boys with MAOA-H had more DB as a function of PSE, controlling for PTE (β=.774, p=.015), and as a function of PTE, controlling for PSE (β=.362, p=.037). Boys with MAOA-L did not show this susceptibility. MAOA did not interact with PSE (β=−.133, p=.561) nor PTE (β= −.144; p=.505) in predicting DB in girls. Examination of gene-environment correlation (rGE) showed a correlation between paternal MAOA-L and daughters’ concurrent stress exposure (r=−.240, p=.013). Discussion Findings underscore complex mechanisms linking genetic susceptibility and early adverse exposures. Replication in larger cohorts followed from the pregnancy through adolescence is suggested to elucidate mechanisms that appear to have varying developmental expression. PMID:28163169
Does MAOA increase susceptibility to prenatal stress in young children?
Massey, Suena H; Hatcher, Amalia E; Clark, Caron A C; Burns, James L; Pine, Daniel S; Skol, Andrew D; Mroczek, Daniel K; Espy, Kimberly A; Goldman, David; Cook, Edwin; Wakschlag, Lauren S
2017-05-01
We previously demonstrated a gene-by-prenatal-environment interaction whereby the monoamine oxidase A gene (MAOA) modified the impact of prenatal tobacco exposure (PTE) on adolescent disruptive behavior (DB), with the MAOA risk genotype varying by sex. We extend this work by examining whether this mechanism is evident with another common adversity, prenatal stress exposure (PSE), and whether sex differences are present earlier in development in closer proximity to exposure. Participants were 281 mothers and their 285 children derived from a prenatal cohort with in-depth prospective measures of PSE and PTE. We assessed DB at age 5 via dimensional developmentally-sensitive measurement. Analyses were stratified by sex based on prior evidence for sex differences. Concurrent stress exposure predicted DB in children (β=0.310, p=0.001), while main effects of prenatal exposures were seen only in boys. We found a three-way interaction of MAOA×PSE×sex on DB (β=0.813, p=0.022). Boys with MAOA-H had more DB as a function of PSE, controlling for PTE (β=0.774, p=0.015), and as a function of PTE, controlling for PSE (β=0.362, p=0.037). Boys with MAOA-L did not show this susceptibility. MAOA did not interact with PSE (β=-0.133, p=0.561) nor PTE (β=-0.144; p=0.505) in predicting DB in girls. Examination of gene-environment correlation (rGE) showed a correlation between paternal MAOA-L and daughters' concurrent stress exposure (r=-0.240, p=0.013). Findings underscore complex mechanisms linking genetic susceptibility and early adverse exposures. Replication in larger cohorts followed from the pregnancy through adolescence is suggested to elucidate mechanisms that appear to have varying developmental expression. Copyright © 2017 Elsevier Inc. All rights reserved.
Deschilder, Koen; De Vos, Rien; Stockman, Willem
2007-07-01
Recent cardio pulmonary resuscitation (CPR) guidelines changed the compression:ventilation ratio in 30:2. To compare the quality of chest compressions and exhaustion using the ratio 30:2 versus 15:2. A prospective, randomised crossover design was used. Subjects were recruited from the H.-Hart hospital personnel and the University College Katho for nurses and bio-engineering. Each participant performed 5min of CPR using either the ratio 30:2 or 15:2, then after a 15min rest switched to the other ratio. The data were collected using a questionnaire and an adult resuscitation manikin. The outcomes included exhaustion as measured by a visual analogue scale (VAS) score, depth of chest compressions, rates of chest compressions, total number of chest compressions, number of correct chest compressions and incomplete release. Data were compared using the Wilcoxon Signed Ranks Test. The results are presented as medians and interquartile ranges (IQR). One hundred and thirty subjects completed the study. The exhaustion-score using the VAS was 5.9 (IQR 2.25) for the ratio 30:2 and 4.5 (IQR 2.88) for the ratio 15:2 (P<0.001). The compression depth was 40.5mm (IQR 15.75) for 30:2 and 41mm (IQR 15.5) for 15:2 (P=0.5). The compression rate was 118beats/min (IQR 29) for 30:2 and 115beats/min (IQR 32) for 15:2 (P=0.02). The total number of compressions/5min was 347 (IQR 79) for 30:2 and 244compressions/5min (IQR 72.5) for 15:2 (P<0.001). The number of correct compression/5min was 61.5 (IQR 211.75) for 30:2 and 55.5 (IQR 142.75) for 15:2 (P=0.001). The relative risk (RR) of incomplete release in 30:2 versus 15:2 was 1.087 (95% CI=0.633-1.867). Although the 30:2 ratio is rated to be more exhausting, the 30:2 technique delivers more chest compressions and the quality of chest compressions remains unchanged.
Ghatnekar, Gautam S; Grek, Christina L; Armstrong, David G; Desai, Sanjay C; Gourdie, Robert G
2015-01-01
The gap junction protein, connexin43 (Cx43), has critical roles in the inflammatory, edematous, and fibrotic processes following dermal injury and during wound healing, and is abnormally upregulated at the epidermal wound margins of venous leg ulcers (VLUs). Targeting Cx43 with ACT1, a peptide mimetic of the carboxyl-terminus of Cx43, accelerates fibroblast migration and proliferation, and wound reepithelialization. In a prospective, multicenter clinical trial conducted in India, adults with chronic VLUs were randomized to treatment with an ACT1 gel formulation plus conventional standard-of-care (SOC) protocols, involving maintaining wound moisture and four-layer compression bandage therapy, or SOC protocols alone. The primary end point was mean percent ulcer reepithelialization from baseline to 12 weeks. A significantly greater reduction in mean percent ulcer area from baseline to 12 weeks was associated with the incorporation of ACT1 therapy (79% (SD 50.4)) as compared with compression bandage therapy alone (36% (SD 179.8); P=0.02). Evaluation of secondary efficacy end points indicated a reduced median time to 50 and 100% ulcer reepithelialization for ACT1-treated ulcers. Incorporation of ACT1 in SOC protocols may represent a well-tolerated, highly effective therapeutic strategy that expedites chronic venous ulcer healing by treating the underlying ulcer pathophysiology through Cx43-mediated pathways. PMID:25072595
Numerical simulation of the compressible Orszag-Tang vortex 2. Supersonic flow
NASA Technical Reports Server (NTRS)
Picone, J. M.; Dahlburg, Russell B.
1990-01-01
The numerical investigation of the Orszag-Tang vortex system in compressible magnetofluids will consider initial conditions with embedded supersonic regions. The simulations have initial average Mach numbers 1.0 and 1.5 and beta 10/3 with Lundquist numbers 50, 100, or 200. The behavior of the system differs significantly from that found previously for the incompressible and subsonic analogs. Shocks form at the downstream boundaries of the embedded supersonic regions outside the central magnetic X-point and produce strong local current sheets which dissipate appreciable magnetic energy. Reconnection at the central X-point, which dominates the incompressible and subsonic systems, peaks later and has a smaller impact as M increases from 0.6 to 1.5. Similarly, correlation between the momentum and magnetic field begins significant growth later than in subsonic and incompressible flows. The shocks bound large compression regions, which dominate the wavenumber spectra of autocorrelations in mass density, velocity, and magnetic field.
Efficient Prediction Structures for H.264 Multi View Coding Using Temporal Scalability
NASA Astrophysics Data System (ADS)
Guruvareddiar, Palanivel; Joseph, Biju K.
2014-03-01
Prediction structures with "disposable view components based" hierarchical coding have been proven to be efficient for H.264 multi view coding. Though these prediction structures along with the QP cascading schemes provide superior compression efficiency when compared to the traditional IBBP coding scheme, the temporal scalability requirements of the bit stream could not be met to the fullest. On the other hand, a fully scalable bit stream, obtained by "temporal identifier based" hierarchical coding, provides a number of advantages including bit rate adaptations and improved error resilience, but lacks in compression efficiency when compared to the former scheme. In this paper it is proposed to combine the two approaches such that a fully scalable bit stream could be realized with minimal reduction in compression efficiency when compared to state-of-the-art "disposable view components based" hierarchical coding. Simulation results shows that the proposed method enables full temporal scalability with maximum BDPSNR reduction of only 0.34 dB. A novel method also has been proposed for the identification of temporal identifier for the legacy H.264/AVC base layer packets. Simulation results also show that this enables the scenario where the enhancement views could be extracted at a lower frame rate (1/2nd or 1/4th of base view) with average extraction time for a view component of only 0.38 ms.
A 205GHz Amplifier in 90nm CMOS Technology
2017-03-01
San Jose State University San Jose, CA, USA Abstract: This paper presents a 205GHz amplifier drawing 43.4mA from a 0.9V power supply with...10.5dB power gain, Psat of -1.6dBm, and P1dB ≈ -5.8dBm in a standard 90nm CMOS process. Moreover, the design employs internal (layout-based) /external...reported in [2]. In this paper, two neutralization techniques, internal and external approaches, have been implemented to achieve higher power
Nieto-Sanjuanero, Adriana; Quero-Jiménez, José; Cantú-Moreno, Daniel; Rodríguez-Balderrama, Isaías; Montes-Tapia, Fernando; Rubio-Pérez, Nadina; Treviño-Garza, Consuelo; de la O-Cavazos, Manuel
2015-01-01
To determine the noise levels of different areas responsible for newborn care, develop intervention strategies to decrease the noise, and evaluate its effectiveness. Prospective, observational and longitudinal study carried out using a sonometer, measuring sound levels for three weeks in the neonatal intensive care unit (NICU), neonatal intermediate care unit (UCIREN), delivery (TOCO QX) and nursery (CUNERO) units. We implemented an intervention program and subsequent measurements were performed under the same initial conditions. When comparing the decibel levels in different areas during the three weeks, pre- and post-intervention, we found at the neonatal intensive care unit 59.9±4.8 vs. 56.4±4.7 dB (p<0.001), neonatal intermediate care unit 55.3±3.9 vs. 51.3±4.4 dB (p<0.001), delivery unit 57.3±4.6 vs. 57.3±5.5 dB (NS), and nursery unit 57.6±5.8 vs. 53.9±5.8 dB (p<0.001). There was a significant reduction in noise levels of 3.5 dB at the NICU, 4 dB at UCIREN and 3.7 dB at TOCO QX, so the intervention program was effective in these areas; however, the decibel levels registered continue above those recommended by international standards.
Leem, Kang-Hyun; Kim, Myung-Gyou; Hahm, Young-Tae; Kim, Hye Kyung
2016-12-09
Opuntia ficus-indica var. saboten (OFS) has been used in traditional medicine for centuries to treat several illnesses, including diabetes. However, detailed mechanisms underlying hypoglycemic effects remain unclear. In this study, the mechanism underlying the hypoglycemic activity of OFS was evaluated using in vitro and in vivo systems. OFS treatment inhibited α-glucosidase activity and intestinal glucose absorption assessed by Na⁺-dependent glucose uptake using brush border membrane vesicles. AMP-activated protein kinase (AMPK) is widely recognized as an important regulator of glucose transport in skeletal muscle, and p38 mitogen-activated protein kinase (MAPK) has been proposed to be a component of AMPK-mediated signaling. In the present study, OFS dose-dependently increased glucose uptake in L6 muscle cells. The AMPK and p38 MAPK phosphorylations were stimulated by OFS, and inhibitors of AMPK (compound C ) and p38 MAPK (SB203580) abolished the effects of OFS. Furthermore, OFS increased glucose transporter 4 (GLUT4) translocation to the plasma membrane. OFS administration (1 g/kg and 2 g/kg body weight) in db/db mice dose-dependently ameliorated hyperglycemia, hyperinsulinemia, and glucose tolerance. Insulin resistance assessed by homeostasis model assessment of insulin resistance and quantitative insulin sensitivity check index were also dose-dependently improved with OFS treatment. OFS administration improved pancreatic function through increased β-cell mass in db/db mice. These findings suggest that OFS acts by inhibiting glucose absorption from the intestine and enhancing glucose uptake from insulin-sensitive muscle cells through the AMPK/p38 MAPK signaling pathway.
Leem, Kang-Hyun; Kim, Myung-Gyou; Hahm, Young-Tae; Kim, Hye Kyung
2016-01-01
Opuntia ficus-indica var. saboten (OFS) has been used in traditional medicine for centuries to treat several illnesses, including diabetes. However, detailed mechanisms underlying hypoglycemic effects remain unclear. In this study, the mechanism underlying the hypoglycemic activity of OFS was evaluated using in vitro and in vivo systems. OFS treatment inhibited α-glucosidase activity and intestinal glucose absorption assessed by Na+-dependent glucose uptake using brush border membrane vesicles. AMP-activated protein kinase (AMPK) is widely recognized as an important regulator of glucose transport in skeletal muscle, and p38 mitogen-activated protein kinase (MAPK) has been proposed to be a component of AMPK-mediated signaling. In the present study, OFS dose-dependently increased glucose uptake in L6 muscle cells. The AMPK and p38 MAPK phosphorylations were stimulated by OFS, and inhibitors of AMPK (compound C) and p38 MAPK (SB203580) abolished the effects of OFS. Furthermore, OFS increased glucose transporter 4 (GLUT4) translocation to the plasma membrane. OFS administration (1 g/kg and 2 g/kg body weight) in db/db mice dose-dependently ameliorated hyperglycemia, hyperinsulinemia, and glucose tolerance. Insulin resistance assessed by homeostasis model assessment of insulin resistance and quantitative insulin sensitivity check index were also dose-dependently improved with OFS treatment. OFS administration improved pancreatic function through increased β-cell mass in db/db mice. These findings suggest that OFS acts by inhibiting glucose absorption from the intestine and enhancing glucose uptake from insulin-sensitive muscle cells through the AMPK/p38 MAPK signaling pathway. PMID:27941667
Implementing Connected Component Labeling as a User Defined Operator for SciDB
NASA Technical Reports Server (NTRS)
Oloso, Amidu; Kuo, Kwo-Sen; Clune, Thomas; Brown, Paul; Poliakov, Alex; Yu, Hongfeng
2016-01-01
We have implemented a flexible User Defined Operator (UDO) for labeling connected components of a binary mask expressed as an array in SciDB, a parallel distributed database management system based on the array data model. This UDO is able to process very large multidimensional arrays by exploiting SciDB's memory management mechanism that efficiently manipulates arrays whose memory requirements far exceed available physical memory. The UDO takes as primary inputs a binary mask array and a binary stencil array that specifies the connectivity of a given cell to its neighbors. The UDO returns an array of the same shape as the input mask array with each foreground cell containing the label of the component it belongs to. By default, dimensions are treated as non-periodic, but the UDO also accepts optional input parameters to specify periodicity in any of the array dimensions. The UDO requires four stages to completely label connected components. In the first stage, labels are computed for each subarray or chunk of the mask array in parallel across SciDB instances using the weighted quick union (WQU) with half-path compression algorithm. In the second stage, labels around chunk boundaries from the first stage are stored in a temporary SciDB array that is then replicated across all SciDB instances. Equivalences are resolved by again applying the WQU algorithm to these boundary labels. In the third stage, relabeling is done for each chunk using the resolved equivalences. In the fourth stage, the resolved labels, which so far are "flattened" coordinates of the original binary mask array, are renamed with sequential integers for legibility. The UDO is demonstrated on a 3-D mask of O(1011) elements, with O(108) foreground cells and O(106) connected components. The operator completes in 19 minutes using 84 SciDB instances.
Sepowitz, John J; Armstrong, Nicholes J; Pasiakos, Stefan M
This study characterized the total daily energy expenditure (TDEE), energy intake (EI), body weight, and diet quality (using the Healthy Eating Index-2010 [HEI]) of 20 male US Marines participating in the 9-month US Marine Corps Forces Special Operations Command Individual Training Course (ITC). TDEE was highest (ρ < .05) during Raider Spirit (RS; 6,376 ± 712kcal/d) compared with Survival, Evasion, Resistance, and Escape (SERE; 4,011 ± 475kcal/d) School, Close-Quarters Battle (CQB; 4,189 ± 476kcal/d), and Derna Bridge (DB; 3,754 ± 314kcal/d). Body mass was lost (ρ < .05) during SERE, RS, and DB because EI was less than TDEE (SERE, -3,665kcal/d ± 475kcal/d; RS, -3,966 ± 776kcal/d; and DB, -1,027 ± 740kcal/d; p < .05). However, body mass was restored before the start of each subsequent phase and was not different between the start (86.4 ± 9.8kg) and end of ITC (86.7 ± 9.0kg). HEI score declined during ITC (before, 65.6 ± 11.2 versus after, 60.9 ± 9.7; p < .05) because less greens or beans and more empty calories were consumed (ρ < .05). Dietary protein intake was lowest during RS (0.9 ± 0.4g/kg) compared with all other phases, and carbohydrate intake during RS (3.6 ± 1g/kg), CQB (3.6 ± 1.0g/kg), and DB (3.7 ± 1.0g/kg) was lower than during the academic phase of SERE (5.1 ± 1.0g/kg; p < .05). These data suggest that ITC students, on average, adequately restore body mass between intermittent periods of negative energy balance. Education regarding the importance of maintaining healthy eating patterns while in garrison, consuming more carbohydrate and protein, and better matching EI with TDEE during strenuous training exercises may be warranted. 2017.
Nishizawa, N; Chen, Y; Hsiung, P; Ippen, E P; Fujimoto, J G
2004-12-15
Real-time, ultrahigh-resolution optical coherence tomography (OCT) is demonstrated in the 1.4-1.7-microm wavelength region with a stretched-pulse, passively mode-locked, Er-doped fiber laser and highly nonlinear fiber. The fiber laser generates 100-mW, linearly chirped pulses at a 51-MHz repetition rate. The pulses are compressed and then coupled into a normally dispersive highly nonlinear fiber to generate a low-noise supercontinuum with a 180-nm FWHM bandwidth and 38 mW of output power. This light source is stable, compact, and broadband, permitting high-speed, real-time, high-resolution OCT imaging. In vivo high-speed OCT imaging of human skin with approximately 5.5-microm resolution and 99-dB sensitivity is demonstrated.
Investigating the Short-term Effect of Eyelid Massage on Corneal Topography.
Riede-Pult, Britta H; Evans, Katharine; Pult, Heiko
2017-06-01
The aim of this study was to evaluate the short-term effect of eyelid massage, after the use of warm compresses, on corneal topography. Corneal topography was evaluated on 20 subjects (mean age, 47.0 [SD ±17.3] years) using the Oculus Keratograph (Oculus, Wetzlar, Germany). Corneal eccentricity (Epsilon) was compared between topography measurements before eyelid warming (using warm compresses) (T1), after eyelid warming (T2), directly after eyelid massage (T3), and 30 minutes after eyelid massage (T4). Differences in corneal eccentricity between the enrolment measurement (T1) and consecutive measurements (T1-4) were analyzed. The contralateral eye-treated by warm compresses, but not by eyelid massage-was the control. Visual acuity (decimal), bulbar conjunctival hyperemia, and corneal staining (Cornea and Contact Lens Research Unit grading scale) were evaluated at T1 and T4 to assess clinical safety. No significant differences were found between consecutive eccentricity measurements overall and with the central radii (repeated-measures analysis of variance, P > .238 (massaged eyelid: Epsilon T1: 0.48 [95% confidence interval, ±0.07], T2: 0.49 [±0.05], T3: 0.49 [±0.06], T4: 0.48 [±0.06]; horizontal radii T1: 7.76 [±0.13] mm, T2: 7.74 [±0.13] mm, T3: 7.75 [±0.13] mm, T4: 7.76 [±0.13] mm; vertical radii T1: 7.56 [±0.12] mm, T2: 7.55 [±0.10] mm, T3: 7.54 [±0.10] mm, T4: 7.58 [±0.11] mm). Decimal visual acuity significantly improved at the end of the study (massaged eyelid: T1: 1.1 [±0.1]; T4: 1.3 [±0.1]; P < .032). No significant differences were detected between the consecutive evaluation of corneal staining (Wilcoxon test; P > .285). Redness was not significantly different between time points (repeated-measures analysis of variance; P = .187) in the colateral eyes. Hyperemia was significantly reduced in the massaged eyes (T1: 2.0 grade units [±0.3]; T4: 1.9 [±0.3]; P = .021). Eyelid warming followed by eyelid massage appears to be a safe procedure, without any clinically relevant short-term effects on the cornea.
Song, Junfeng; Luo, Xianshu; Tu, Xiaoguang; Jia, Lianxi; Fang, Qing; Liow, Tsung-Yang; Yu, Mingbin; Lo, Guo-Qiang
2013-05-20
In this work, we demonstrate thermo-optical quasi-digital optical switch (q-DOS) using silicon microring resonator-coupled Mach-Zehnder interferometer. The optical transmission spectra show box-like response with 1-dB and 3-dB bandwidths of ~1.3 nm and ~1.6 nm, respectively. Such broadband flat-top optical response improves the tolerance to the light source wavelength fluctuation of ± 6 Å and temperature variation of ± 6 °C. Dynamic characterizations show the device with switching power of ~37 mW, switching time of ~7 μs, and on/off ratio of > 30 dB. For performance comparison, we also demonstrate a carrier injection-based electro-optical q-DOS by integrating lateral P-i-N junction with the microring resonator, which significantly reduces power consumption to ~12 mW and switching time to ~0.7 ns only.
Baseline 24-2 Central Visual Field Damage Is Predictive of Global Progressive Field Loss.
Garg, Aakriti; De Moraes, C Gustavo; Cioffi, George A; Girkin, Christopher A; Medeiros, Felipe A; Weinreb, Robert N; Zangwill, Linda M; Liebmann, Jeffrey M
2018-03-01
Central visual field (VF) damage in glaucoma patients can significantly hinder daily activities. The present study investigates whether the presence of localized baseline damage to the central 10 degrees of the VF is predictive of faster global mean deviation (MD) progression. Prospective cohort study. Eyes from the multicenter African Descent and Glaucoma Evaluation Study (ADAGES) with established glaucoma and VF loss and a minimum of 5 24-2 VFs were eligible. Baseline central 24-2 damage was defined as any of the 12 central-most points with total deviation (TD) values at P < 0.5% on 2 consecutive examinations. Progression was determined using trend-based and event-based criteria: (1) rates of MD change significantly faster than zero and (2) >-5 dB MD loss over the entire follow-up. A total of 827 eyes of 584 patients were studied. Mean rate of MD change of the entire sample was -0.15 dB/year (95% CI: -0.19 to -0.12, P < .001). Eyes with baseline central damage progressed faster than those without (difference: β central = -0.07 dB/year, 95% CI: -0.11 to -0.01, P = .011) and were more likely to experience MD loss greater than 5 dB (hazard ratio = 3.0 [95% CI: 2.1-4.1, P < .001]). These differences remained significant after adjusting for confounders. The presence of central VF damage at baseline is significantly associated with more rapid global progression. Detection of central VF damage aids in stratification of high-risk patients who may need intensive surveillance and aggressive treatment. Copyright © 2018 Elsevier Inc. All rights reserved.
Pytte, Morten; Kramer-Johansen, Jo; Eilevstjønn, Joar; Eriksen, Morten; Strømme, Taevje A; Godang, Kristin; Wik, Lars; Steen, Petter Andreas; Sunde, Kjetil
2006-12-01
Adrenaline (epinephrine) is used during cardiopulmonary resuscitation (CPR) based on animal experiments without supportive clinical data. Clinically CPR was reported recently to have much poorer quality than expected from international guidelines and what is generally done in laboratory experiments. We have studied the haemodynamic effects of adrenaline during CPR with good laboratory quality and with quality simulating clinical findings and the feasibility of monitoring these effects through VF waveform analysis. After 4 min of cardiac arrest, followed by 4 min of basic life support, 14 pigs were randomised to ClinicalCPR (intermittent manual chest compressions, compression-to-ventilation ratio 15:2, compression depth 30-38 mm) or LabCPR (continuous mechanical chest compressions, 12 ventilations/min, compression depth 45 mm). Adrenaline 0.02 mg/kg was administered 30 s thereafter. Plasma adrenaline concentration peaked earlier with LabCPR than with ClinicalCPR, median (range), 90 (30, 150) versus 150 (90, 270) s (p = 0.007), respectively. Coronary perfusion pressure (CPP) and cortical cerebral blood flow (CCBF) increased and femoral blood flow (FBF) decreased after adrenaline during LabCPR (mean differences (95% CI) CPP 17 (6, 29) mmHg (p = 0.01), FBF -5.0 (-8.8, -1.2) ml min(-1) (p = 0.02) and median difference CCBF 12% of baseline (p = 0.04)). There were no significant effects during ClinicalCPR (mean differences (95% CI) CPP 4.7 (-3.2, 13) mmHg (p = 0.2), FBF -0.2 (-4.6, 4.2) ml min(-1)(p = 0.9) and CCBF 3.6 (-1.8, 9.0)% of baseline (p = 0.15)). Slope VF waveform analysis reflected changes in CPP. Adrenaline improved haemodynamics during laboratory quality CPR in pigs, but not with quality simulating clinically reported CPR performance.
2015-01-01
The dimensions and arrangements of aromatic rings (topology) in adducts derived from the reactions of polycyclic aromatic hydrocarbon (PAH) diol epoxide metabolites with DNA influence the distortions and stabilities of double-stranded DNA, and hence their recognition and processing by the human nucleotide excision repair (NER) system. Dibenzo[a,l]pyrene (DB[a,l]P) is a highly tumorigenic six-ring PAH, which contains a nonplanar and aromatic fjord region that is absent in the structurally related bay region five-ring PAH benzo[a]pyrene (B[a]P). The PAH diol epoxide–DNA adducts formed include the stereoisomeric 14S and 14Rtrans-anti-DB[a,l]P-N2-dG and the stereochemically analogous 10S- and 10R-B[a]P-N2-dG (B[a]P-dG) guanine adducts. However, nuclear magnetic resonance (NMR) solution studies of the 14S-DB[a,l]P-N2-dG adduct in DNA have not yet been presented. Here we have investigated the 14S-DB[a,l]P-N2-dG adduct in two different sequence contexts using NMR methods with distance-restrained molecular dynamics simulations. In duplexes with dC opposite the adduct deleted, a well-resolved base-displaced intercalative adduct conformation can be observed. In full duplexes, in contrast to the intercalated 14R stereoisomeric adduct, the bulky DB[a,l]P residue in the 14S adduct is positioned in a greatly widened and distorted minor groove, with significant disruptions and distortions of base pairing at the lesion site and two 5′-side adjacent base pairs. These unique structural features are significantly different from those of the stereochemically analogous but smaller B[a]P-dG adduct. The greater size and different topology of the DB[a,l]P aromatic ring system lead to greater structurally destabilizing DNA distortions that are partially compensated by stabilizing DB[a,l]P-DNA van der Waals interactions, whose combined effects impact the NER response to the adduct. These structural results broaden our understanding of the structure–function relationship in NER. PMID:24617538
Cuttability Assessment of Selected Rocks Through Different Brittleness Values
NASA Astrophysics Data System (ADS)
Dursun, Arif Emre; Gokay, M. Kemal
2016-04-01
Prediction of cuttability is a critical issue for successful execution of tunnel or mining excavation projects. Rock cuttability is also used to determine specific energy, which is defined as the work done by the cutting force to excavate a unit volume of yield. Specific energy is a meaningful inverse measure of cutting efficiency, since it simply states how much energy must be expended to excavate a unit volume of rock. Brittleness is a fundamental rock property and applied in drilling and rock excavation. Brittleness is one of the most crucial rock features for rock excavation. For this reason, determination of relations between cuttability and brittleness will help rock engineers. This study aims to estimate the specific energy from different brittleness values of rocks by means of simple and multiple regression analyses. In this study, rock cutting, rock property, and brittleness index tests were carried out on 24 different rock samples with different strength values, including marble, travertine, and tuff, collected from sites around Konya Province, Turkey. Four previously used brittleness concepts were evaluated in this study, denoted as B 1 (ratio of compressive to tensile strength), B 2 (ratio of the difference between compressive and tensile strength to the sum of compressive and tensile strength), B 3 (area under the stress-strain line in relation to compressive and tensile strength), and B 9 = S 20, the percentage of fines (<11.2 mm) formed in an impact test for the Norwegian University of Science and Technology (NTNU) model as well as B 9p (B 9 as predicted from uniaxial compressive, Brazilian tensile, and point load strengths of rocks using multiple regression analysis). The results suggest that the proposed simple regression-based prediction models including B 3, B 9, and B 9p outperform the other models including B 1 and B 2 and can be used for more accurate and reliable estimation of specific energy.
Binary power multiplier for electromagnetic energy
Farkas, Zoltan D.
1988-01-01
A technique for converting electromagnetic pulses to higher power amplitude and shorter duration, in binary multiples, splits an input pulse into two channels, and subjects the pulses in the two channels to a number of binary pulse compression operations. Each pulse compression operation entails combining the pulses in both input channels and selectively steering the combined power to one output channel during the leading half of the pulses and to the other output channel during the trailing half of the pulses, and then delaying the pulse in the first output channel by an amount equal to half the initial pulse duration. Apparatus for carrying out each of the binary multiplication operation preferably includes a four-port coupler (such as a 3 dB hybrid), which operates on power inputs at a pair of input ports by directing the combined power to either of a pair of output ports, depending on the relative phase of the inputs. Therefore, by appropriately phase coding the pulses prior to any of the pulse compression stages, the entire pulse compression (with associated binary power multiplication) can be carried out solely with passive elements.
Measurement of Nitrogen Hyperfine Structure on the 53 CM (562 MHz) Butyronitrile Line
NASA Astrophysics Data System (ADS)
Dewberry, Christopher T.; Grubbs, Garry S. Grubbs, II; Raphelt, Andrew; Cooke, Stephen A.
2009-06-01
Recent improvements to our cavity-based Fourier transform radiofrequency spectrometer will be presented. Amongst other improvements use of Miteq amp, model AMF-6F-00100400-10-10P (0.1 GHz to 4 GHz, 65 dB gain minimum, 1 dB noise figure maximum) together with shielding from an improved Faraday cage have significantly helped us in this regard. Electromagnetic fields within our near-spherical cavity have been modeled and results will be presented. We have been able to easily resolve the nitrogen hyperfine structure on the ^aQ_{0,-1} transition 1_{1,0} ← 1_{1,1} located at 562 MHz. This result will be discussed.
Forsum, Elisabet; Henriksson, Pontus; Löf, Marie
2014-01-01
A possibility to assess body composition during pregnancy is often important. Estimating body density (DB) and use the two-component model (2CM) to calculate total body fat (TBF) represents an option. However, this approach has been insufficiently evaluated during pregnancy. We evaluated the 2CM, and estimated fat-free mass (FFM) density and variability in 17 healthy women before pregnancy, in gestational weeks 14 and 32, and 2 weeks postpartum based on DB (underwater weighing), total body water (deuterium dilution) and body weight, assessed on these four occasions. TBF, calculated using the 2CM and published FFM density (TBF2CM), was compared to reference estimates obtained using the three-component model (TBF3CM). TBF2CM minus TBF3CM (mean ± 2SD) was −1.63 ± 5.67 (p = 0.031), −1.39 ± 7.75 (p = 0.16), −0.38 ± 4.44 (p = 0.49) and −1.39 ± 5.22 (p = 0.043) % before pregnancy, in gestational weeks 14 and 32 and 2 weeks postpartum, respectively. The effect of pregnancy on the variability of FFM density was larger in gestational week 14 than in gestational week 32. The 2CM, based on DB and published FFM density, assessed body composition as accurately in gestational week 32 as in non-pregnant adults. Corresponding values in gestational week 14 were slightly less accurate than those obtained before pregnancy. PMID:25526240
Effects of steam inhalation on voice quality-related acoustic measures.
Mahalingam, Shenbagavalli; Boominathan, Prakash
2016-10-01
To investigate the effects of steam inhalation using a facial steamer on voice quality-related acoustic measures. Prospective outcome research: single-blinded experimental study. Forty-five vocally healthy female subjects ranging in age from 18 to 30 years (Mean age: 22.41 years; standard deviation [SD]: 8.91) participated in the study. Phonation samples were recorded under three different conditions in triplicate: baseline recording, immediately after mouth breathing (dehydration), and immediately after 3 minutes of steam inhalation via the mouth (rehydration). In the initial voice recording (prior to dehydration), mean jitter (0.42 %; SD: 0.07), shimmer (2.20 dB; SD: 0.45), and harmonics-to-noise ratio (HNR) (21.60; SD: 2.41) values were within normal limits. After short-term mouth breathing (dehydration, approximately 10 minutes), the mean jitter (1.57 %; SD: 1.82) and shimmer (4.73 dB; SD: 1.83) were significantly increased (P < 0.05), and HNR (18.64; SD: 3.16) was reduced (P < 0.05). After steam inhalation (rehydration) for 3 minutes, mean jitter (0.48 %; SD: 0.12) and shimmer (2.70 dB; SD: 0.71) showed significant decrease (P < 0.05), and HNR (20.10; SD: 3.69) showed significant increase (P < 0.05). All parameters statistically significantly improved from post dehydration values. The simple procedure of steam inhalation using a facial steamer displayed positive effects on parameters proposed to reflect voice quality. 4. Laryngoscope, 126:2305-2309, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Han, Jing; Sun, Lidan; Huang, Xun; Li, Zheng; Zhang, Chenyu; Qian, Hai; Huang, Wenlong
2014-12-01
The short biological half-life limits the therapeutic use of glucagon-like peptide-1 (GLP-1) and chemical modification to improve the interaction of peptides with serum albumin represents an effective strategy to develop long-acting peptide analogues. Coumarin, a natural product, is known to bind tightly to plasma proteins and possesses many biological activities. Therefore, we designed and synthesized a series of coumarin-modified GLP-1 derivatives, hypothesizing that conjugation with coumarin would retain the therapeutic effects and prolong the biological half-life of the conjugates. Four cysteine-modified GLP-1 analogues (1-4) were prepared using Gly8 -GLP-1(7-36)-NH2 peptide as a starting point. These analogues were conjugated with two coumarin maleimides to yield eight compounds (conjugates 6-13) for testing. Activation of human GLP-1 receptors, stability to enzymic inactivation in plasma and binding to human albumin were assessed in vitro. In vivo, effects on oral glucose tolerance tests (OGTT) in rats and on blood glucose levels in db/db mice were studied. Most conjugates showed well preserved receptor activation efficacy, enhanced albumin-binding properties and improved in vitro plasma stability and conjugate 7 was selected to undergo further assessment. In rats, conjugate 7 had a longer circulating t1/2 than exendin-4 or liraglutide. A prolonged antidiabetic effect of conjugate 7 was observed after OGTT in rats and a prolonged hypoglycaemic effect in db/db mice. Cysteine-specific coumarin conjugation with GLP-1 offers a useful approach to the development of long-acting incretin-based antidiabetic agents. Conjugate 7 is a promising long-lasting GLP-1 derivative deserving further investigation. © 2014 The British Pharmacological Society.
Han, Jing; Sun, Lidan; Huang, Xun; Li, Zheng; Zhang, Chenyu; Qian, Hai; Huang, Wenlong
2014-01-01
Background and Purpose The short biological half-life limits the therapeutic use of glucagon-like peptide-1 (GLP-1) and chemical modification to improve the interaction of peptides with serum albumin represents an effective strategy to develop long-acting peptide analogues. Coumarin, a natural product, is known to bind tightly to plasma proteins and possesses many biological activities. Therefore, we designed and synthesized a series of coumarin-modified GLP-1 derivatives, hypothesizing that conjugation with coumarin would retain the therapeutic effects and prolong the biological half-life of the conjugates. Experimental Approach Four cysteine-modified GLP-1 analogues (1–4) were prepared using Gly8-GLP-1(7–36)-NH2 peptide as a starting point. These analogues were conjugated with two coumarin maleimides to yield eight compounds (conjugates 6–13) for testing. Activation of human GLP-1 receptors, stability to enzymic inactivation in plasma and binding to human albumin were assessed in vitro. In vivo, effects on oral glucose tolerance tests (OGTT) in rats and on blood glucose levels in db/db mice were studied. Key Results Most conjugates showed well preserved receptor activation efficacy, enhanced albumin-binding properties and improved in vitro plasma stability and conjugate 7 was selected to undergo further assessment. In rats, conjugate 7 had a longer circulating t1/2 than exendin-4 or liraglutide. A prolonged antidiabetic effect of conjugate 7 was observed after OGTT in rats and a prolonged hypoglycaemic effect in db/db mice. Conclusions and Implications Cysteine-specific coumarin conjugation with GLP-1 offers a useful approach to the development of long-acting incretin-based antidiabetic agents. Conjugate 7 is a promising long-lasting GLP-1 derivative deserving further investigation. PMID:25039358
A 10 bit 200 MS/s pipeline ADC using loading-balanced architecture in 0.18 μm CMOS
NASA Astrophysics Data System (ADS)
Wang, Linfeng; Meng, Qiao; Zhi, Hao; Li, Fei
2017-07-01
A new loading-balanced architecture for high speed and low power consumption pipeline analog-to-digital converter (ADC) is presented in this paper. The proposed ADC uses SHA-less, op-amp and capacitor-sharing technique, capacitor-scaling scheme to reduce the die area and power consumption. A new capacitor-sharing scheme was proposed to cancel the extra reset phase of the feedback capacitors. The non-standard inter-stage gain increases the feedback factor of the first stage and makes it equal to the second stage, by which, the load capacitor of op-amp shared by the first and second stages is balanced. As for the fourth stage, the capacitor and op-amp no longer scale down. From the system’s point of view, all load capacitors of the shared OTAs are balanced by employing a loading-balanced architecture. The die area and power consumption are optimized maximally. The ADC is implemented in a 0.18 μm 1P6M CMOS technology, and occupies a die area of 1.2 × 1.2 mm{}2. The measurement results show a 55.58 dB signal-to-noise-and-distortion ratio (SNDR) and 62.97 dB spurious-free dynamic range (SFDR) with a 25 MHz input operating at a 200 MS/s sampling rate. The proposed ADC consumes 115 mW at 200 MS/s from a 1.8 V supply.
Munro, K J; Lazenby, A
2001-10-01
The electroacoustic characteristics of a hearing instrument are normally selected for individuals using data obtained during audiological assessment. The precise inter-relationship between the electroacoustic and audiometric variables is most readily appreciated when they have been measured at the same reference point, such as the tympanic membrane. However, it is not always possible to obtain the real-ear sound pressure level (SPL) directly if this is below the noise floor of the probe-tube microphone system or if the subject is unco-operative. The real-ear SPL may be derived by adding the subject's real-ear to dial difference (REDD) acoustic transform to the audiometer dial setting. The aim of the present study was to confirm the validity of the Audioscan RM500 to measure the REDD with the ER-3A insert earphone. A probe-tube microphone was used to measure the real-ear SPL and REDD from the right ears of 16 adult subjects ranging in age from 22 to 41 years (mean age 27 years). Measurements were made from 0.25 kHz to 6 kHz at a dial setting of 70 dB with an ER-3A insert earphone and two earmould configurations: the EAR-LINK foam ear-tip and the subjects' customized skeleton earmoulds. Mean REDD varied as a function of frequency but was typically approximately 12 dB with a standard deviation (SD) of +/- 1.7 dB and +/- 2.7 dB for the foam ear-tip and customized earmould, respectively. The mean test-retest difference of the REDD varied with frequency but was typically 0.5 dB (SD 1 dB). Over the frequency range 0.5-4 kHz, the derived values were found to be within 5 dB of the measured values in 95% of subjects when using the EAR-LINK foam ear-tip and within 4 dB when using the skeleton earmould. The individually measured REDD transform can be used in clinical practice to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.
Adaptive Arrays for Multiple Simultaneous Desired Signals.
1983-08-01
weights [Equation (4)]. Using Equation (6), the inverse of the covariance matrix is given by 5 4 i *ŕm * T ". -1 1 I d Z dij (7) L -I + UT U* 4 di x di...Equations (11) and (12) p k = A k Ik d (14) dk aki*~~* ( ~ dk LJk Udk) and 1 t IjI II di l() 27 x = (1 + t UT U*) Thus, the output SNR of the kth desired...signals are assumed to be of the same frequency. There is no jammer 9 0 dB SIGNAL 10 dB SIGNAL 90 % 90 180 Fiur .dptdpatrnofalier rayo tn strpc lmet
2012-01-01
Background Diabetes is one of the risk factors for cognitive deficits such as Alzheimer’s disease. To obtain a better understanding of the anti-dementia effect of chotosan (CTS), a Kampo formula, we investigated its effects on cognitive and emotional deficits of type 2 diabetic db/db mice and putative mechanism(s) underlying the effects. Methods Seven-week-old db/db mice received daily administration of CTS (375 – 750 mg/kg, p.o.) and the reference drug tacrine (THA: 2.5 mg/kg, i.p.) during an experimental period of 7 weeks. From the age of 9-week-old, the animals underwent the novel object recognition test, the modified Y-maze test, and the water maze test to elucidate cognitive performance and the elevated plus maze test to elucidate anxiety-related behavior. After completing behavioral studies, Western blotting and immunohistochemical studies were conducted. Results Compared with age-matched non-diabetic control strain (m/m) mice, db/db mice exhibited impaired cognitive performance and an increased level of anxiety. CTS ameliorated cognitive and emotional deficits of db/db mice, whereas THA improved only cognitive performance. The phosphorylated levels of Akt and PKCα in the hippocampus were significantly lower and higher, respectively, in db/db mice than in m/m mice. Expression levels of the hippocampal cholinergic marker proteins and the number of the septal cholinergic neurons were also reduced in db/db mice compared with those in m/m mice. Moreover, the db/db mice had significantly reduced levels of vasculogenesis/angiogenesis factors, vascular endothelial growth factor (VEGF), VEGF receptor type 2, platelet-derived growth factor-B, and PDGF receptor β, in the hippocampus. CTS and THA treatment reversed these neurochemical and histological alterations caused by diabetes. Conclusion These results suggest that CTS ameliorates diabetes-induced cognitive deficits by protecting central cholinergic and VEGF/PDGF systems via Akt signaling pathway and that CTS exhibits the anxiolytic effect via neuronal mechanism(s) independent of cholinergic or VEGF/PDGF systems in db/db mice. PMID:23082896
Zhao, Qi; Niu, Yimin; Matsumoto, Kinzo; Tsuneyama, Koichi; Tanaka, Ken; Miyata, Takeshi; Yokozawa, Takako
2012-10-20
Diabetes is one of the risk factors for cognitive deficits such as Alzheimer's disease. To obtain a better understanding of the anti-dementia effect of chotosan (CTS), a Kampo formula, we investigated its effects on cognitive and emotional deficits of type 2 diabetic db/db mice and putative mechanism(s) underlying the effects. Seven-week-old db/db mice received daily administration of CTS (375 - 750 mg/kg, p.o.) and the reference drug tacrine (THA: 2.5 mg/kg, i.p.) during an experimental period of 7 weeks. From the age of 9-week-old, the animals underwent the novel object recognition test, the modified Y-maze test, and the water maze test to elucidate cognitive performance and the elevated plus maze test to elucidate anxiety-related behavior. After completing behavioral studies, Western blotting and immunohistochemical studies were conducted. Compared with age-matched non-diabetic control strain (m/m) mice, db/db mice exhibited impaired cognitive performance and an increased level of anxiety. CTS ameliorated cognitive and emotional deficits of db/db mice, whereas THA improved only cognitive performance. The phosphorylated levels of Akt and PKCα in the hippocampus were significantly lower and higher, respectively, in db/db mice than in m/m mice. Expression levels of the hippocampal cholinergic marker proteins and the number of the septal cholinergic neurons were also reduced in db/db mice compared with those in m/m mice. Moreover, the db/db mice had significantly reduced levels of vasculogenesis/angiogenesis factors, vascular endothelial growth factor (VEGF), VEGF receptor type 2, platelet-derived growth factor-B, and PDGF receptor β, in the hippocampus. CTS and THA treatment reversed these neurochemical and histological alterations caused by diabetes. These results suggest that CTS ameliorates diabetes-induced cognitive deficits by protecting central cholinergic and VEGF/PDGF systems via Akt signaling pathway and that CTS exhibits the anxiolytic effect via neuronal mechanism(s) independent of cholinergic or VEGF/PDGF systems in db/db mice.
Rescue of cardiac leptin receptors in db/db mice prevents myocardial triglyceride accumulation.
Hall, Michael E; Maready, Matthew W; Hall, John E; Stec, David E
2014-08-01
Increased leptin levels have been suggested to contribute to cardiac hypertrophy and attenuate cardiac lipid accumulation in obesity, although it has been difficult to separate leptin's direct effects from those caused by changes in body weight and adiposity. To determine whether leptin attenuates cardiac lipid accumulation in obesity or directly causes left ventricular hypertrophy (LVH), we generated a novel mouse model in which the long form of the leptin receptor (LepR) was "rescued" only in cardiomyocytes of obese db/db mice. Reexpression of cardiomyocyte leptin receptors in db/db mice did not cause LVH but reduced cardiac triglycerides and improved cardiac function. Compared with lean wild-type (WT) or db/db-cardiac LepR rescue mice, db/db mice exhibited significantly lower E/A ratio, a measurement of early to late diastolic filling, which averaged 1.5 ± 0.07 in db/db vs. 1.9 ± 0.08 and 1.8 ± 0.11 in WT and db/db-cardiac LepR rescue mice, respectively. No differences in systolic function were observed. Although db/db and db/db-cardiac LepR rescue mice exhibited similar increases in plasma triglycerides, insulin, glucose, and body weight, cardiac triglycerides were significantly higher in db/db compared with WT and db/db cardiac LepR rescue mice, averaging 13.4 ± 4.2 vs. 3.8 ± 1.6 vs. 3.8 ± 0.7 mg/g, respectively. These results demonstrate that despite significant obesity and increases in plasma glucose and triglycerides, db/db cardiac LepR rescue mice are protected against myocardial lipid accumulation. However, we found no evidence that leptin directly causes LVH. Copyright © 2014 the American Physiological Society.
Measurement of Retinal Sensitivity on Tablet Devices in Age-Related Macular Degeneration.
Wu, Zhichao; Guymer, Robyn H; Jung, Chang J; Goh, Jonathan K; Ayton, Lauren N; Luu, Chi D; Lawson, David J; Turpin, Andrew; McKendrick, Allison M
2015-06-01
We compared measurements of central retinal sensitivity on a portable, low-cost tablet device to the established method of microperimetry in age-related macular degeneration (AMD). A customized test designed to measure central retinal sensitivity (within the central 1° radius) on a tablet device was developed using an open-source platform called PsyPad. A total of 30 participants with AMD were included in this study, and all participants performed a practice test on PsyPad, followed by four tests of one eye and one test of the other eye. Participants then underwent standardized microperimetry examinations in both eyes. The average test duration on PsyPad was 53.9 ± 7.5 seconds, and no significant learning effect was observed over the examinations performed ( P = 1.000). The coefficient of repeatability of central retinal sensitivity between the first two examinations on PsyPad was ±1.76 dB. The mean central retinal sensitivity was not significantly different between PsyPad (25.7 ± 0.4 dB) and microperimetry (26.1 ± 0.4 dB, P = 0.094), and the 95% limits of agreement between the two measures were between -4.12 and 4.92 dB. The measurements of central retinal sensitivity can be performed effectively using a tablet device, displaying reasonably good agreement with those obtained using the established method of microperimetry. These findings highlight the potential of tablet devices as low-cost and portable tools for developing and performing visual function measures that can be easily and widely implemented.
Differentiating between adductor and abductor spasmodic dysphonia using airflow interruption
Hoffman, Matthew R.; Jiang, Jack J.; Rieves, Adam L.; McElveen, Kelsey A.B.; Ford, Charles N.
2009-01-01
Objective To measure the laryngeal resistance (RL), subglottal pressure (Ps), and mean flow rate (MFR) of adductor (ADSD) and abductor (ABSD) spasmodic dysphonia patients using the airflow interrupter. Methods The RL of six ABSD and seven ADSD patients was measured using the airflow interrupter, a noninvasive device designed to measure MFR and Ps via mechanical balloon valve interruption. Subjects performed ten trials at each of two intensity levels, with each trial consisting of a sustained /a/ during which phonation was interrupted for 500 ms. Laryngeal resistance was calculated as subglottal pressure divided by airflow. Results Mean RL for the ADSD and ABSD subtypes at 65 dB were 24.78 cmH2O/l/s and 14.51 cmH2O/l/s, respectively (p = 0.04). Mean RL at 70 dB were 40.02 cmH2O/l/s and 15.84 cmH2O/l/s (p = 0.014). Ps for the ADSD and ABSD subtypes at 65 dB were 10.23 cmH2O and 8.32 cmH2O, respectively (p = 0.582). At the 70 dB level, Ps were 12.39 cmH2O and 11.78 cmH2O (p = 0.886). MFR for the ADSD and ABSD subtypes at 65 dB were 435 ml/s and 746 ml/s (p = 0.205). Mean MFR at 70 dB were 518 ml/s and 848 ml/s (p = 0.198). Conclusion Noninvasive measurements of RL may be useful for differentiating between ADSD and ABSD. This simple objective test which produces a quantitative output could be used to evaluate laryngeal function in patients with spasmodic dysphonia. PMID:19554636
NASA Technical Reports Server (NTRS)
Carpenter, Mark H.; Parsani, Matteo; Fisher, Travis C.; Nielsen, Eric J.
2015-01-01
Staggered grid, entropy stable discontinuous spectral collocation operators of any order are developed for Burgers' and the compressible Navier-Stokes equations on unstructured hexahedral elements. This generalization of previous entropy stable spectral collocation work [1, 2], extends the applicable set of points from tensor product, Legendre-Gauss-Lobatto (LGL) to a combination of tensor product Legendre-Gauss (LG) and LGL points. The new semi-discrete operators discretely conserve mass, momentum, energy and satisfy a mathematical entropy inequality for both Burgers' and the compressible Navier-Stokes equations in three spatial dimensions. They are valid for smooth as well as discontinuous flows. The staggered LG and conventional LGL point formulations are compared on several challenging test problems. The staggered LG operators are significantly more accurate, although more costly to implement. The LG and LGL operators exhibit similar robustness, as is demonstrated using test problems known to be problematic for operators that lack a nonlinearly stability proof for the compressible Navier-Stokes equations (e.g., discontinuous Galerkin, spectral difference, or flux reconstruction operators).
Wide-Range Motion Estimation Architecture with Dual Search Windows for High Resolution Video Coding
NASA Astrophysics Data System (ADS)
Dung, Lan-Rong; Lin, Meng-Chun
This paper presents a memory-efficient motion estimation (ME) technique for high-resolution video compression. The main objective is to reduce the external memory access, especially for limited local memory resource. The reduction of memory access can successfully save the notorious power consumption. The key to reduce the memory accesses is based on center-biased algorithm in that the center-biased algorithm performs the motion vector (MV) searching with the minimum search data. While considering the data reusability, the proposed dual-search-windowing (DSW) approaches use the secondary windowing as an option per searching necessity. By doing so, the loading of search windows can be alleviated and hence reduce the required external memory bandwidth. The proposed techniques can save up to 81% of external memory bandwidth and require only 135 MBytes/sec, while the quality degradation is less than 0.2dB for 720p HDTV clips coded at 8Mbits/sec.
Ediani Machado, Michely; Tomazoni, Fernanda; Ruffo Ortiz, Fernanda; Ardenghi, Thiago Machado; Zanatta, Fabricio Batistin
2017-07-01
It is not clear how using partial-mouth periodontal examination (PMPE) protocols affects estimates of the association between gingival bleeding (GB) and oral health-related quality of life (OHRQoL). The aim of the present study is to assess impact of different PMPEs on the association between GB and OHRQoL in 12-year-old adolescents. A total of 1,134 adolescents were evaluated for clinical and subjective variables. GB was determined by full-mouth examination (FME) of six sites (disto-buccal [DB], mid-buccal [B], mesio-buccal [MB], disto-lingual [DL], mid-lingual, and mesio-lingual [ML]) and different PMPEs were calculated using a 15% cut-off point: 1) full-mouth (MB-B-DB/MB-B-DL); 2) two diagonal quadrants (six sites/MB-B-DB/MB-B-DL); 3) two randomly selected half-mouth quadrants (six sites/MB-B-DB/ MB-B-DL/MB-DB-ML-DL); and 4) the community periodontal index. OHRQoL was assessed using the Child Perceptions Questionnaire (CPQ 11-14 ). Adjusted negative binomial regression models were used to calculate the rate ratio of CPQ 11-14 scores for each PMPE. Adolescents with GB showed significantly poorer OHRQoL than their counterparts when FME was used. In contrast, more than half of PMPE protocols did not detect significant associations between GB and CPQ 11-14 scores in the adjusted analysis. Using PMPE to assess GB in adolescents significantly affects associations with OHRQoL outcomes, depending on the protocol used. PMPEs that evaluated MB-B-DL sites of randomly selected half-mouth quadrants (1 or 2 and 3 or 4) achieved results closer to those obtained with FME.
A Novel Method of Newborn Chest Compression: A Randomized Crossover Simulation Study.
Smereka, Jacek; Szarpak, Lukasz; Ladny, Jerzy R; Rodriguez-Nunez, Antonio; Ruetzler, Kurt
2018-01-01
Objective: To compare a novel two-thumb chest compression technique with standard techniques during newborn resuscitation performed by novice physicians in terms of median depth of chest compressions, degree of full chest recoil, and effective compression efficacy. Patients and Methods: The total of 74 novice physicians with less than 1-year work experience participated in the study. They performed chest compressions using three techniques: (A) The new two-thumb technique (nTTT). The novel method of chest compressions in an infant consists in using two thumbs directed at the angle of 90° to the chest while closing the fingers of both hands in a fist. (B) TFT. With this method, the rescuer compresses the sternum with the tips of two fingers. (C) TTHT. Two thumbs are placed over the lower third of the sternum, with the fingers encircling the torso and supporting the back. Results: The median depth of chest compressions for nTTT was 3.8 (IQR, 3.7-3.9) cm, for TFT-2.1 (IQR, 1.7-2.5) cm, while for TTHT-3.6 (IQR, 3.5-3.8) cm. There was a significant difference between nTTT and TFT, and TTHT and TFT ( p < 0.001) for each time interval during resuscitation. The degree of full chest recoil was 93% (IQR, 91-97) for nTTT, 99% (IQR, 96-100) for TFT, and 90% (IQR, 74-91) for TTHT. There was a statistically significant difference in the degree of complete chest relaxation between nTTT and TFT ( p < 0.001), between nTTT and TTHT ( p = 0.016), and between TFT and TTHT ( p < 0.001). Conclusion: The median chest compression depth for nTTT and TTHT is significantly higher than that for TFT. The degree of full chest recoil was highest for TFT, then for nTTT and TTHT. The effective compression efficiency with nTTT was higher than for TTHT and TFT. Our novel newborn chest compression method in this manikin study provided adequate chest compression depth and degree of full chest recoil, as well as very good effective compression efficiency. Further clinical studies are necessary to confirm these initial results.
Zhao, Fan; Xue, Wen; Wang, Fujun; Liu, Laijun; Shi, Haoqin; Wang, Lu
2018-08-01
Stents are vital devices to treat vascular stenosis in pediatric patients with congenital heart disease. Bioresorbable stents (BRSs) have been applied to reduce challenging complications caused by permanent metal stents. However, it remains almost a total lack of BRSs with satisfactory compression performance specifically for children with congenital heart disease, leading to importantly suboptimal effects. In this work, composite bioresorbable prototype stents with superior compression resistance were designed by braiding and annealing technology, incorporating poly (p-dioxanone) (PPDO) monofilaments and polycaprolactone (PCL) multifilament. Stent prototype compression properties were investigated. The results revealed that novel composite prototype stents showed superior compression force compared to the control ones, as well as recovery ability. Furthermore, deformation mechanisms were analyzed by computational simulation, which revealed bonded interlacing points among yarns play an important role. This research presents important clinical implications in bioresorbable stent manufacture and provides further study with an innovative stent design. Copyright © 2018 Elsevier Ltd. All rights reserved.
Effects of Compression, Staging, and Braid Angle on Braided Rope Seal Performance
NASA Technical Reports Server (NTRS)
Steinetz, Bruce M.; Dunlap, Patrick H.; Adams, Michael L.
2006-01-01
This viewgraph presentation describes the effects of compression, staging and braid angle on braided rope seals. The contents include: 1) Test Fixture Schematics; 2) Comparison of Hybrid Seal Braid Architecture; 3) Residual Interference After Compression Cycling; 4) Effect of Compression, Braid, and Staging on Seal Flow; 5) Effect of Staging on Seal Pressure Drop; 6) Three Stag Seal Durability; 7) P&W Turbine Vane Seal Requirements; and 8) Next Generation Fighter F-22 P&W F119 Engines.
Su, Guanyong; Letcher, Robert J; Farmahin, Reza; Crump, Doug
2018-03-01
Tetradecabromo-1,4-diphenoxybenzene (TeDB-DiPhOBz) and 2,2',3,3',4,4',5,5',6,6'-decabromodiphenyl ether (BDE-209) are flame retardant chemicals that can undergo photolytic degradation. The present study compared the time-dependent photolyic degradation of TeDB-DiPhOBz and BDE-209, and dioxin-like product formation as a result of (UV) irradiation (I; irradiation time periods of 0, 1, 4, 15 and 40 days). Photo-degraded product fractions of UV-I-TeDB-DiPhOBz (nominal concentration: 1.9 μM) were administered to chicken embryonic hepatocytes (CEH), and significant induction of CYP1A4/5 mRNA expression was observed for fractions collected at the day 15 and 40 time points (fold change of 7.3/3.6 and 9.1/4.7, respectively). For the UV-I-BDE-209 fractions (nominal concentration: 10 μM), significant CYP1A4/5 up-regulation occurred at all time points, and the fraction collected on day 1 induced the greatest fold change of 510/86, followed by 410/68 (day 4) and 110/26 (day 15), respectively. For the UV-I-BDE-209 fraction collected at day 40, significant CEH cytotoxicity was observed. As a result, CYP1A4/5 expression was determined at a nominal concentration of 1 μM instead of 10 μM and CYP1A4/5 fold changes of 11/8.2 (day 40) were observed. Fractions eliciting the greatest CYP1A4/5 mRNA upregulation were further screened for transcriptomic effects using a PCR array comprising 27 dioxin-responsive genes. A total of 6 and 16 of the 27 target genes were up or down-regulated following UV-I-TeDB-DiPhOBz and UV-I-BDE-209 exposure, respectively. Overall, and regardless of the formation rate, these results raise concerns regarding the potential formation of dioxin-like compounds from flame retardants in products and materials such as plastics, and in natural sunlight irradiation situations in the environment (e.g. in landfill sites or electronic waste facilities). Copyright © 2017 Elsevier Ltd. All rights reserved.
Diffusive Public Goods and Coexistence of Cooperators and Cheaters on a 1D Lattice
Scheuring, István
2014-01-01
Many populations of cells cooperate through the production of extracellular materials. These materials (enzymes, siderophores) spread by diffusion and can be applied by both the cooperator and cheater (non-producer) cells. In this paper the problem of coexistence of cooperator and cheater cells is studied on a 1D lattice where cooperator cells produce a diffusive material which is beneficial to the individuals according to the local concentration of this public good. The reproduction success of a cell increases linearly with the benefit in the first model version and increases non-linearly (saturates) in the second version. Two types of update rules are considered; either the cooperative cell stops producing material before death (death-production-birth, DpB) or it produces the common material before it is selected to die (production-death-birth, pDB). The empty space is occupied by its neighbors according to their replication rates. By using analytical and numerical methods I have shown that coexistence of the cooperator and cheater cells is possible although atypical in the linear version of this 1D model if either DpB or pDB update rule is assumed. While coexistence is impossible in the non-linear model with pDB update rule, it is one of the typical behaviors in case of the non-linear model with DpB update rule. PMID:25025985
2013-01-01
ξi be the Legendre -Gauss-Lobatto (LGL) points defined as the roots of (1 − ξ2)P ′N (ξ) = 0, where PN (ξ) is the N th order Legendre polynomial . The...mesh refinement. By expanding the solution in a basis of high order polynomials in each element, one can dynamically adjust the order of these basis...on refining the mesh while keeping the polynomial order constant across the elements. If we choose to allow non-conforming elements, the challenge in
Carrier-envelope offset frequency stabilization of an ultrafast semiconductor laser
NASA Astrophysics Data System (ADS)
Jornod, Nayara; Gürel, Kutan; Wittwer, Valentin J.; Brochard, Pierre; Hakobyan, Sargis; Schilt, Stéphane; Waldburger, Dominik; Keller, Ursula; Südmeyer, Thomas
2018-02-01
We present the self-referenced stabilization of the carrier-envelope offset (CEO) frequency of a semiconductor disk laser. The laser is a SESAM-modelocked VECSEL emitting at a wavelength of 1034 nm with a repetition frequency of 1.8 GHz. The 270-fs pulses are amplified to 3 W and compressed to 120 fs for the generation of a coherent octavespanning supercontinuum spectrum. A quasi-common-path f-to-2f interferometer enables the detection of the CEO beat with a signal-to-noise ratio of 30 dB sufficient for its frequency stabilization. The CEO frequency is phase-locked to an external reference with a feedback signal applied to the pump current.
Tabb, Keri L.; Hellwege, Jacklyn N.; Palmer, Nicholette D.; Dimitrov, Latchezar; Sajuthi, Satria; Taylor, Kent D.; NG, Maggie C.Y.; Hawkins, Gregory A.; Chen, Yii-Der Ida; Brown, W. Mark; McWilliams, David; Williams, Adrienne; Lorenzo, Carlos; Norris, Jill M.; Long, Jirong; Rotter, Jerome I.; Curran, Joanne E.; Blangero, John; Wagenknecht, Lynne E.; Langefeld, Carl D.; Bowden, Donald W.
2017-01-01
Summary Family-based methods are a potentially powerful tool to identify trait-defining genetic variants in extended families, particularly when used to complement conventional association analysis. We utilized two-point linkage analysis and single variant association analysis to evaluate whole exome sequencing (WES) data from 1,205 Hispanic Americans (78 families) from the Insulin Resistance Atherosclerosis Family Study. WES identified 211,612 variants above the minor allele frequency threshold of ≥0.005. These variants were tested for linkage and/or association with 50 cardiometabolic traits after quality control checks. Two-point linkage analysis yielded 10,580,600 LOD scores with 1,148 LOD scores ≥3, 183 LOD scores ≥4, and 29 LOD scores ≥5. The maximal novel LOD score was 5.50 for rs2289043:T>C, in UNC5C with subcutaneous adipose tissue volume. Association analysis identified 13 variants attaining genome-wide significance (p<5×10-08), with the strongest association between rs651821:C>T in APOA5, and triglyceride levels (p=3.67×10-10). Overall, there was a 5.2-fold increase in the number of informative variants detected by WES compared to exome chip analysis in this population, nearly 30% of which were novel variants relative to dbSNP build 138. Thus, integration of results from two-point linkage and single-variant association analysis from WES data enabled identification of novel signals potentially contributing to cardiometabolic traits. PMID:28067407
Inner ear contribution to bone conduction hearing in the human.
Stenfelt, Stefan
2015-11-01
Bone conduction (BC) hearing relies on sound vibration transmission in the skull bone. Several clinical findings indicate that in the human, the skull vibration of the inner ear dominates the response for BC sound. Two phenomena transform the vibrations of the skull surrounding the inner ear to an excitation of the basilar membrane, (1) inertia of the inner ear fluid and (2) compression and expansion of the inner ear space. The relative importance of these two contributors were investigated using an impedance lumped element model. By dividing the motion of the inner ear boundary in common and differential motion it was found that the common motion dominated at frequencies below 7 kHz but above this frequency differential motion was greatest. When these motions were used to excite the model it was found that for the normal ear, the fluid inertia response was up to 20 dB greater than the compression response. This changed in the pathological ear where, for example, otosclerosis of the stapes depressed the fluid inertia response and improved the compression response so that inner ear compression dominated BC hearing at frequencies above 400 Hz. The model was also able to predict experimental and clinical findings of BC sensitivity in the literature, for example the so called Carhart notch in otosclerosis, increased BC sensitivity in superior semicircular canal dehiscence, and altered BC sensitivity following a vestibular fenestration and RW atresia. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Nasution, A. B.; Efendi, S.; Suwilo, S.
2018-04-01
The amount of data inserted in the form of audio samples that use 8 bits with LSB algorithm, affect the value of PSNR which resulted in changes in image quality of the insertion (fidelity). So in this research will be inserted audio samples using 5 bits with MLSB algorithm to reduce the number of data insertion where previously the audio sample will be compressed with Arithmetic Coding algorithm to reduce file size. In this research will also be encryption using Triple DES algorithm to better secure audio samples. The result of this research is the value of PSNR more than 50dB so it can be concluded that the image quality is still good because the value of PSNR has exceeded 40dB.
Ellingson, Benjamin M; Salamon, Noriko; Woodworth, Davis C; Yokota, Hajime; Holly, Langston T
2018-05-01
OBJECTIVE The purpose of this study was to quantify the reproducibility, temporal stability, and functional correlation of diffusion MR characteristics in the spinal cord in patients with cervical stenosis with or without myelopathy. The association between longitudinal diffusion tensor imaging (DTI) measurements and serial neurological function assessment was explored at both the group and individual level. METHODS Sixty-six nonoperatively treated patients with cervical stenosis were prospectively followed (3 months to > 5 years) using synchronous serial MRI and functional outcome assessment. A total of 183 separate MRI examinations were performed, separated by at least 3 months, and each patient had a minimum of 2 MRI scans (range 2-5 scans). Anatomical and DTI measurements were performed within the spinal cord at the C1-2 region as well as at the area of highest compression. Coefficients of variance (COVs) were compared across measurements in both reference tissue and areas of compression for anatomical measurements, fractional anisotropy (FA), and mean diffusivity (MD). The correlation between diffusion MR measures at the site of compression and evaluations of neurological function assessed using the modified Japanese Orthopaedic Association (mJOA) scale at multiple time points was evaluated. RESULTS The COVs for anatomical measurements (Torg ratio and canal diameter) were between 7% and 10%. The median COV for FA measurements at the site of compression was 9%, and for reference tissue at C1-2 it was 6%. The median COV for MD at the site of compression was approximately 12%, and for reference tissue at C1-2 it was 10%. The FA and MD measurements of C1-2 averaged 0.61 and 0.91 μm 2 /msec, respectively, whereas the FA and MD measurements at the site of compression averaged 0.51 and 1.26 μm 2 /msec, respectively. Both FA (slope = 0.037; R 2 = 0.3281, p < 0.0001) and MD (slope = -0.074; R 2 = 0.1101, p = 0.0084) were significantly correlated with the mJOA score. The FA decreased by approximately 0.032 units per mJOA unit decrease (R 2 = 0.2037, p < 0.0001), whereas the MD was increased by approximately 0.084 μm 2 /msec for every mJOA unit decrease (R 2 = 0.1016, p < 0.0001). CONCLUSIONS Quantitative DTI measurements of the spinal cord in patients with cervical stenosis with or without myelopathy have a median COV of 5%-10%, similar to anatomical measurements. The reproducibility of these measurements and significant correlation with functional outcome status suggest a potential role in the evaluation and longitudinal surveillance of nonoperatively treated patients. With respect to the specific DTI measurements, FA within the spinal cord appears slightly more sensitive to neurological function and more stable than measures of MD. Therefore, DTI of the spinal cord may be a clinically feasible imaging technique for longitudinally monitoring patients with cervical spondylotic myelopathy.
Muqit, Mahiul M K; Young, Lorna B; McKenzie, Rod; John, Binu; Marcellino, George R; Henson, David B; Turner, George S; Stanga, Paulo E
2013-02-01
To investigate the short-term effects of high-density 20-ms laser on macular thickness using Pascal-targeted retinal photocoagulation (TRP) and reduced fluence/minimally-traumatic panretinal photocoagulation (MT-PRP) compared to standard-intensity PRP (SI-PRP) in proliferative diabetic retinopathy (PDR). Prospective randomised clinical trial. Treatment-naive PDR was treated with single-session 20-ms Pascal 2500 burns photocoagulation randomised to one of three treatment arms (TRP:MT-PRP:SI-PRP). Primary outcome measure was change in central retinal thickness (CRT) on OCT. Secondary outcomes at 4 and 12 weeks post-laser included: OCT peripapillary nerve fibre layer (NFL) thickness; PDR disease regression on Optos angiography; SITA-Std visual fields (VF); and, visual acuity (VA). 30 eyes of 24 patients were studied, ten eyes/arm. At 12 weeks, there were significant reductions in CRT after TRP (9.6 µm; 95% CI, 1.84 to 17.36; p=0.021) and MT-PRP (17.1 µm; 95% CI, 11 to 23.2; p=0.001), versus SI-PRP (+5.9 µm; 95% CI, -6.75 to 18.55; p=0.32). PDR regression was similar between groups (TRP 70%; MT-PRP 70%; SI-PRP 90%; κ=0.76). No significant changes in VA and NFL thickness developed between groups. The VF mean deviation scores increased significantly in all groups at 12 weeks ([TRP, +0.70dB; 95% CI, 0.07 to 1.48; p=0.07], [MT-PRP, +0.63dB; 95% CI, 0.12 to 1.15; p=0.02], [SI-PRP, +1.0dB; 95% CI, 0.19 to 1.74; p=0.02]). There were no laser-related ocular complications. This pilot study reports that high-density 20-ms Pascal TRP and MT-PRP using 2500 burns did not produce increased macular thickness or any ocular adverse events during the short-term.
SGLT2 Protein Expression Is Increased in Human Diabetic Nephropathy
Wang, Xiaoxin X.; Levi, Jonathan; Luo, Yuhuan; Myakala, Komuraiah; Herman-Edelstein, Michal; Qiu, Liru; Wang, Dong; Peng, Yingqiong; Grenz, Almut; Lucia, Scott; Dobrinskikh, Evgenia; D'Agati, Vivette D.; Koepsell, Hermann; Kopp, Jeffrey B.; Rosenberg, Avi Z.; Levi, Moshe
2017-01-01
There is very limited human renal sodium gradient-dependent glucose transporter protein (SGLT2) mRNA and protein expression data reported in the literature. The first aim of this study was to determine SGLT2 mRNA and protein levels in human and animal models of diabetic nephropathy. We have found that the expression of SGLT2 mRNA and protein is increased in renal biopsies from human subjects with diabetic nephropathy. This is in contrast to db-db mice that had no changes in renal SGLT2 protein expression. Furthermore, the effect of SGLT2 inhibition on renal lipid content and inflammation is not known. The second aim of this study was to determine the potential mechanisms of beneficial effects of SGLT2 inhibition in the progression of diabetic renal disease. We treated db/db mice with a selective SGLT2 inhibitor JNJ 39933673. We found that SGLT2 inhibition caused marked decreases in systolic blood pressure, kidney weight/body weight ratio, urinary albumin, and urinary thiobarbituric acid-reacting substances. SGLT2 inhibition prevented renal lipid accumulation via inhibition of carbohydrate-responsive element-binding protein-β, pyruvate kinase L, SCD-1, and DGAT1, key transcriptional factors and enzymes that mediate fatty acid and triglyceride synthesis. SGLT2 inhibition also prevented inflammation via inhibition of CD68 macrophage accumulation and expression of p65, TLR4, MCP-1, and osteopontin. These effects were associated with reduced mesangial expansion, accumulation of the extracellular matrix proteins fibronectin and type IV collagen, and loss of podocyte markers WT1 and synaptopodin, as determined by immunofluorescence microscopy. In summary, our study showed that SGLT2 inhibition modulates renal lipid metabolism and inflammation and prevents the development of nephropathy in db/db mice. PMID:28196866
NASA Astrophysics Data System (ADS)
Zhang, Zhibo; Wang, Enyuan; Chen, Dong; Li, Xuelong; Li, Nan
2016-11-01
In this paper, the P-wave velocities in different directions of sandstone samples under uniaxial compression are measured. The results indicate that the changes in the P-wave velocity in different directions are almost the same. In the initial stage of loading, the P-wave velocity exhibits a rising trend due to compaction and closure of preexisting fissures. As the stress increase, preexisting fissures are closed but induced fractures are not yet generated. The sandstone samples become denser and more uniform. The P-wave velocity remains in a steady state at a high level. In the late stage of loading, the P-wave velocity drops significantly due to the expansion and breakthrough of induced fractures. The P-wave velocity anisotropy index ε is analyzed during the process of loading. It can be observed that the change in the degree of wave velocity anisotropy can be divided into three stages: the AB stage, the BC stage and the CD stage, with a changing trend from decline to incline. In the initial stage of loading, the preexisting fissures have a randomized distribution, and the change is large-scale and uniform. The difference in each spatial point decreases gradually, and synchronization increases gradually. Thus, the P-wave velocity anisotropy declines. As the stress increases gradually, with the expansion and breakthrough of induced fractures, the difference in each spatial point increases. Before failure of rock samples, the violent change region of the rock samples' internal structure is focused on a narrow two-dimensional zone, and the rock samples' structural change is obviously local. Therefore, the degree of velocity anisotropy rises after declining, and it also has good corresponding relation among the AE count, the location of AE events and the degree of wave velocity anisotropy. The projection plane of the main fracture plane on the axis plane is recorded as M plane. Based on the AFF equation, for the CD stage, we analyze the quantitative relationship between the velocity anisotropy index ε and angle θ, which is the difference between the angle of the M plane and the X plane and the angle of the M plane and the Y plane from the theoretical point. The results indicate that 1/ε and cotθ/2 have good negative linear relationship that can be expressed as cotθ/2 = a ∗1/ε + b. According to experimental data, the linear fit of 1/ε and cotθ/2 is found, obtaining cotθ/2 = - 0.04721/ε + 0.03, with a linear fit index of 0.908. From an experimental point of view, the linear relationship between 1/ε and cotθ/2 is verified. Through this research, we propose a new method for quantitatively predicting the main fracture occurrence position by P-wave velocity anisotropy. This work has an important significance for understanding buckling failure of rocks.
The Association of Glaucomatous Visual Field Loss and Balance
de Luna, Regina A.; Mihailovic, Aleksandra; Nguyen, Angeline M.; Friedman, David S.; Gitlin, Laura N.; Ramulu, Pradeep Y.
2017-01-01
Purpose To relate balance measures to visual field (VF) damage from glaucoma. Methods The OPAL kinematic system measured balance, as root mean square (RMS) sway, on 236 patients with suspect/diagnosed glaucoma. Balance was measured with feet shoulder width apart while standing on a firm/foam surface with eyes opened/closed (Instrumental Clinical Test of Sensory Integration and Balance [ICTSIB] conditions), and eyes open on a firm surface under feet together, semi-tandem, or tandem positions (standing balance conditions). Integrated VF (IVF) sensitivities were calculated by merging right and left eye 24-2 VF data. Results Mean age was 71 years (range, 57–93) and mean IVF sensitivity was 27.1 dB (normal = 31 dB). Lower IVF sensitivity was associated with greater RMS sway during eyes-open foam-surface testing (β = 0.23 z-score units/5 dB IVF sensitivity decrement, P = 0.001), but not during other ICTSIB conditions. Lower IVF sensitivity also was associated with greater RMS sway during feet together standing balance testing (0.10 z-score units/5 dB IVF sensitivity decrement, P = 0.049), but not during other standing balance conditions. Visual dependence of balance was lower in patients with worse IVF sensitivity (β = −21%/5 dB IVF sensitivity decrement, P < 0.001). Neither superior nor inferior IVF sensitivity consistently predicted balance measures better than measures of overall VF sensitivity. Conclusions Balance was worse in glaucoma patients with greater VF damage under foam surface testing (designed to inhibit proprioceptive contributions to balance) as well as feet-together firm-surface conditions when somatosensory inputs were available. Translational Relevance Good balance is essential to avoid unnecessary falls and patients with VF loss from glaucoma may be at higher risk of falls because of poor balance. PMID:28553562
Kim, Sung Hee; Choung, Se Young
2010-02-01
In previous study, the anti-diabetic effect of Cinnamomi Cassiae extract (Cinnamon bark: Lauraceae) in a type II diabetic animal model (C57BIKsj db/db) has been reported. To explore their mechanism of action, in present study, the effect of cinnamon extract on anti-hyperglycemia and anti-hyperlipidemia was evaluated by measuring the blood glucose levels, serum insulin, and adiponectin levels, serum and hepatic lipids, PPARalpha mRNA expression in liver and PPARgamma mRNA expression in adipose tissue, respectively. Male C57BIKs db/db mice were divided into a diabetic group and cinnamon extract treated group and examined for a period of 12 weeks (200 mg/kg, p.o). The fasting blood glucose and postprandial 2 h blood glucose levels in the cinnamon treated group were significantly lower than those in the control group (p < 0.01), whereas the serum insulin and adiponectin levels were significantly higher in the cinnamon treated group than in the control group (p < 0.05). The serum lipids and hepatic lipids were improved in the cinnamon administered group. Also the PPARalpha mRNA (liver) and PPARgamma mRNA (adipose tissue) expression levels were increased significantly in the cinnamon treated group (p < 0.05). Our results suggest that cinnamon extract significantly increases insulin sensitivity, reduces serum, and hepatic lipids, and improves hyperglycemia and hyperlipidemia possibly by regulating the PPAR-medicated glucose and lipid metabolism.
Srikantan, Shoba Krishnan; Berg, Robert A; Cox, Tim; Tice, Lisa; Nadkarni, Vinay M
2005-05-01
Optimal chest compression to ventilation ratio (C:V) for one-rescuer cardiopulmonary resuscitation (CPR) is not known, with current American Heart Association recommendations 3:1 for newborns, 5:1 for children, and 15:2 for adults. C:V ratios influence effectiveness of CPR, but memorizing different ratios is educationally cumbersome. We hypothesized that a 10:2 ratio might provide adequate universal application for all age arrest victims. Clinical study. Tertiary care children's hospital. Thirty-five health care providers. Thirty-five health care providers performed 5-min epochs of one-rescuer CPR at C:V ratios of 3:1, 5:1, 10:2, and 15:2 in random order on infant, pediatric, and adult manikins. Compressions were paced at 100/min by metronome. The number of effective compressions and ventilations delivered per minute was recorded by a trained basic life support instructor. Subjective assessments of fatigue (self-report) and exertion (change in rescuer pulse rate compared with baseline) were assessed. Analysis was by repeated measures analysis of variance and paired Student's t-test. Effective infant compressions per minute did not differ by C:V ratio, but ventilations per minute were greater at 3:1 vs. 5:1, 10:2, and 15:2 (p < .05). Effective pediatric compressions per minute were less at 3:1 vs. 5:1, 10:2, and 15:2 (p < .05) and not different between 5:1, 10:2, and 15:2 ratios. Effective pediatric ventilations per minute were greater at 3:1 than all other ratios and both 5:1 and 10:2 were >15:2 (p < .05). Effective adult compressions per minute were progressively greater with 3:1 vs. 5:1 vs. 10:2 vs. 15:2 (p < .05). Self-efficacy was assessed, and rescuers always subjectively rated 10:2 and 15:2 ratios as easier than 5:1 or 3:1 ratios for all manikins. Rescuer pulse change (exertion) was greater after pediatric and adult vs. infant CPR (p < .05), with no significant difference by C:V ratio. C:V ratio and manikin size have a significant influence on the number of effective compressions and ventilations delivered during ideal, metronome-paced, one-rescuer CPR. Low ratios of 3:1, 5:1, and 10:2 favor ventilation, and high ratios of 15:2 favor compression, especially in adult manikins. Rescuers subjectively preferred C:V ratios of 10:2 and 15:2 over 3:1 or 5:1. Infant CPR caused less exertion and subjective fatigue than pediatric or adult CPR technique, without significant difference by C:V ratio. We speculate that a universal 10:2 C:V ratio for one-rescuer layperson CPR is physiologically reasonable but warrants further study with particular attention to educational value and technique retention.
Just, Armin; Wittmann, Uwe; Ehmke, Heimo; Kirchheim, Hartmut R
1998-01-01
The aim of this study was to investigate the autoregulation of renal blood flow under physiological conditions, when challenged by the normal pressure fluctuations, and the contribution of the tubuloglomerular feedback (TGF). The transfer function between 0.0018 and 0.5 Hz was calculated from the spontaneous fluctuations in renal arterial blood pressure (RABP) and renal blood flow (RBF) in conscious resting dogs. The response of RBF to stepwise artificially induced reductions in RABP was also studied (stepwise autoregulation). Under control conditions (n = 12 dogs), the gain of the transfer function started to decrease, indicating improving autoregulation, below 0.06-0.15 Hz (t = 7-17 s). At 0.027 Hz a prominent peak of high gain was found. Below 0.01 Hz (t > 100 s), the gain reached a minimum (maximal autoregulation) of -6.3 ± 0.6 dB. The stepwise autoregulation (n = 4) was much stronger (-19.5 dB). The time delay of the transfer function was remarkably constant from 0.03 to 0.08 Hz (high frequency (HF) range) at 1.7 s and from 0.0034 to 0.01 Hz (low frequency (LF) range) at 14.3 s, respectively. Nifedipine, infused into the renal artery, abolished the stepwise autoregulation (-2.0 ± 1.1 dB, n = 3). The gain of the transfer function (n = 4) remained high down to 0.0034 Hz; in the LF range it was higher than in the control (0.3 ± 1.0 dB, P < 0.05). The time delay in the HF range was reduced to 0.5 s (P < 0.05). After ganglionic blockade (n = 7) no major changes in the transfer function were observed. Under furosemide (frusemide) (40 mg + 10 mg h−1 or 300 mg + 300 mg h−1 i.v.) the stepwise autoregulation was impaired to -7.8 ± 0.3 or -6.7 ± 1.9 dB, respectively (n = 4). In the transfer function (n = 7 or n = 4) the peak at 0.027 Hz was abolished. The delay in the LF range was reduced to -1.1 or -1.6 s, respectively. The transfer gain in the LF range (-5.5 ± 1.2 or -3.8 ± 0.8 dB, respectively) did not differ from the control but was smaller than that under nifedipine (P < 0.05). It is concluded that the ample capacity for regulation of RBF is only partially employed under physiological conditions. The abolition by nifedipine and the negligible effect of ganglionic blockade show that above 0.0034 Hz it is almost exclusively due to autoregulation by the kidney itself. TGF contributes to the maximum autoregulatory capacity, but it is not required for the level of autoregulation expended under physiological conditions. Around 0.027 Hz, TGF even reduces the degree of autoregulation. PMID:9481688
[Synthesis and monolayer behaviors of 4-methyl-5-hydroxy-ethyl isothiazole stearic ester].
Shen, Yu-hua; Kong, Lin; Yang, Jia-xiang; Xie, An-jian; Qian, Jia-sheng; Ouyang, Jian-ming; Xia, Bing
2002-12-01
4-methyl-5-hydroxy-ethyl isothiazole stearic ester (HISE) was synthesized and characterized by FTIR spectroscopy, 1H NMR and MS. The monolayer-forming ability of HISE was studied in subphases with different pH values using isotherms of surface pressure-area per molecule (pi-A). It was observed that the collapse pressure and the film-forming ability of the monolayers of HISE increased gradually as pH values ascended. Research of differentiated pi-A curves (d pi(/dA-A) indicated that there were one or two phase change points during the compressing process, and the incompressibility and the stability of HISE monolayers on alkalescent subphases were better than on acid subphases.
DOT National Transportation Integrated Search
2017-03-30
A 1 dB decrease in the carrier-to-noise (C/N) ratio is equivalent to a -6 dB interference-to-noise (I/N) ratio and a 1 dB increase in the noise floor ((I+N)/N). Regulations alternate between referencing the 1 dB decrease in C/N, -6 dB I/N ratio, and ...
Experimental investigation of shock-cell noise reduction for dual-stream nozzles in simulated flight
NASA Technical Reports Server (NTRS)
Janardan, B. A.; Yamamoto, K.; Majjigi, R. K.; Brausch, J. F.
1984-01-01
Six scale-model nozzles were tested in an anechoic facility to evauate the effectiveness of convergent-divergent (C-D) terminations in reducing shock-cell noise of unsuppressed and mechanically suppressed coannular plug nozzles. One hundred fifty-three acoustic test points with inverted velocity profiles were conducted under static and simulated flight conditions. Diagnostic flow visualization with a shadowgraph and velocity measurements with a laser velocimeter were performed on selected plumes. Shock-cells were identified on the plug and downstream of the plug of the unsuppressed convergent coannular nozzle with truncated plug. Broadband peak frequencies predicted with the two shock-cell structures were correlated with the observed spectra using the measured shock-cell spacings. Relative to a convergent circular nozzle, the perceived noise level (PNL) data at an observer angle of 60 deg relative to inlet, indicated a reduction of (1) 6.5 dB and 9.2 dB with unsuppressed C-D coannular nozzle with truncated plug and (2) 7.7 dB and 8.3 dB with suppressed C-D coannular nozzle under static and simulated flight conditions, espectively. The unsuppressed C-D coannular nozzle with truncated plug, operating at the C-D design condition, had shock-cells downstream of the plug with no shock-cells on the plug. The downstream shock-cells were eliminated by replacing the truncated plug with a smooth extension to obtain an additional 2.4 dB and 3 dB front quadrant PNL reduction, under static and simulated flight conditions, respectively. Other results are discussed.
Frontal auditory evoked potentials and augmenting-reducing.
Bruneau, N; Roux, S; Garreau, B; Lelord, G
1985-09-01
Auditory evoked potentials (AEPs) to tones (750 Hz--200 msec) ranging from 50 to 80 dB SPL were studied at Cz and Fz leads in 29 normal adults (15 males) ranging in age from 20 to 22. Peak-to-trough amplitudes were measured for the P1-N1 and the N1-P2 wave forms as well as baseline (500 msec prestimulus)-to-peak amplitudes for each component, i.e., P1, N1 and P2. Amplitudes were examined as a function of intensity and electrode location. Cz-Fz amplitude differences increased with increasing stimulus intensity, the differentiating peak being the N1 component. An overall reducing phenomenon was found at Fz in the 70-80 dB range whereas an augmenting effect was observed at Cz for these intensities. The augmenting/reducing groups defined by analysis of individual amplitude-intensity patterns were different whether we considered Fz or Cz results: Fz reducers were more numerous than Cz reducers. These results on prominent reducing at the frontal level were examined in relation to the data concerning the modulatory function of the frontal cortex on auditory EPs. Implications were drawn for the role of the frontal cortex in cortical augmenting-reducing.
Pneumatic Compression, But Not Exercise, Can Avoid Intradialytic Hypotension: A Randomized Trial.
Álvares, Valeria R C; Ramos, Camila D; Pereira, Benedito J; Pinto, Ana Lucia; Moysés, Rosa M A; Gualano, Bruno; Elias, Rosilene M
2017-01-01
Conventional hemodialysis (HD) is associated with dialysis-induced hypotension (DIH) and ineffective phosphate removal. As the main source of extracellular fluid removed during HD are the legs, we sought to reduce DIH and increase phosphate removal by using cycling and pneumatic compression, which would potentially provide higher venous return, preserving central blood flow and also offering more phosphate to the dialyzer. We evaluated 21 patients in a randomized crossover fashion in which each patient underwent 3 different HD: control; cycling exercise during the first 60 min; and pneumatic compression during the first 60 min. Data obtained included bioelectrical impedance, hourly blood pressure measurement, biochemical parameters, and direct quantification of phosphate through the dialysate. DIH was defined as a drop in mean arterial pressure (MAP) ≥20 mm Hg. There was no difference in the ultrafiltration rate (p = 0.628), delta weight (p = 0.415), delta of total, intra and extracellular body water among the control, cycling, and pneumatic compression (p = 0.209, p = 0.348, and p = 0.467 respectively). Delta MAP was less changed by pneumatic compression when compared to control, cycling, and pneumatic compression respectively (-4.7 [-17.2, 8.2], -4.7 [-20.5, -0.2], and -2.3 [-8.1, 9.0] mm Hg; p = 0.021). DIH occurred in 43, 38, and 24% of patients in control, cycling, and pneumatic compression respectively (p = 0.014). Phosphate removal did not increase in any intervention (p = 0.486). Higher phosphate removal was dependent on ultrafiltration, pre dialysis serum phosphate, and higher parathyroid hormone. Pneumatic compression during the first hour of dialysis was associated with less DIH, albeit there was no effect on fluid parameters. Neither exercise nor pneumatic compression increased phosphate removal. © 2017 S. Karger AG, Basel.
Jo, Choong Hyun; Cho, Gyu Chong; Lee, Chang Hee
2017-07-01
The purpose of this study was to determine if the over-the-head 2-thumb encircling technique (OTTT) provides better overall quality of cardiopulmonary resuscitation compared with conventional 2-finger technique (TFT) for a lone rescuer in the setting of infant cardiac arrest in ambulance. Fifty medical emergency service students were voluntarily recruited to perform lone rescuer infant cardiopulmonary resuscitation for 2 minutes on a manikin simulating a 3-month-old baby in an ambulance. Participants who performed OTTT sat over the head of manikins to compress the chest using a 2-thumb encircling technique and provide bag-valve mask ventilations, whereas those who performed TFT sat at the side of the manikins to compress using 2-fingers and provide pocket-mask ventilations. Mean hands-off time was not significantly different between OTTT and TFT (7.6 ± 1.1 seconds vs 7.9 ± 1.3 seconds, P = 0.885). Over-the-head 2-thumb encircling technique resulted in greater depth of compression (42.6 ± 1.4 mm vs 41.0 ± 1.4 mm, P < 0.001) and faster rate of compressions (114.4 ± 8.0 per minute vs 112.2 ± 8.2 per minute, P = 0.019) than TFT. Over-the-head 2-thumb encircling technique resulted in a smaller fatigue score than TFT (1.7 ± 1.5 vs 2.5 ± 1.6, P < 0.001). In addition, subjects reported that compression, ventilation, and changing compression to ventilation were easier in OTTT than in TFT. The use of OTTT may be a suitable alternative to TFT in the setting of cardiac arrest of infants during ambulance transfer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kubo, Fumiyo; Miyatsuka, Takeshi, E-mail: miyatsuka-takeshi@umin.net; Department of Medicine, Metabolism and Endocrinology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421
2016-02-26
Glucagon-like peptide 1 (GLP-1) has been shown to play important roles in maintaining β-cell functions, such as insulin secretion and proliferation. While expression levels of GLP-1 receptor (Glp1r) are compromised in the islets of diabetic rodents, it remains unclear when and to what degree Glp1r mRNA levels are decreased during the progression of diabetes. In this study, we performed real-time PCR with the islets of db/db diabetic mice at different ages, and found that the expression levels of Glp1r were comparable to those of the islets of nondiabetic db/misty controls at the age of four weeks, and were significantly decreasedmore » at the age of eight and 12 weeks. To investigate whether restored expression of Glp1r affects the diabetic phenotypes, we generated the transgenic mouse model Pdx1{sup PB}-CreER{sup TM}; CAG-CAT-Glp1r (βGlp1r) that allows for induction of Glp1r expression specifically in β cells. Whereas the expression of exogenous Glp1r had no measurable effect on glucose tolerance in nondiabetic βGlp1r;db/misty mice, βGlp1r;db/db mice exhibited higher glucose and lower insulin levels in blood on glucose challenge test than control db/db littermates. In contrast, four weeks of treatment with exendin-4 improved the glucose profiles and increased serum insulin levels in βGlp1r;db/db mice, to significantly higher levels than those in control db/db mice. These differential effects of exogenous Glp1r in nondiabetic and diabetic mice suggest that downregulation of Glp1r might be required to slow the progression of β-cell failure under diabetic conditions. - Highlights: • Expression levels of incretin receptors were significantly decreased in diabetic db/db islets after the age of eight weeks. • A transgenic mouse model expressing Glp1r specifically in β cells was generated. • Exogenous expression of Glp1r in β cells did not affect metabolic profiles in nondiabetic mice. • Sustained expression of Glp1r in diabetic db/db β cells deteriorated glucose profiles, but significantly improved insulin secretion after treatment with a GLP-1 analog.« less
Characteristics of the ToxRefDB In Vivo Datasets from Chronic, Reproductive and Developmental Assays
ToxRefDB was developed to store data from in vivo animal toxicity studies. The initial focus was populating ToxRefDB with pesticide registration toxicity data that has been historically stored as hard-copy and scanned documents by the Office of Pesticide Programs. A significant p...
NASA Technical Reports Server (NTRS)
Gardiner, Arthur W
1927-01-01
This report summarizes some results obtained with a single cylinder test engine at the Langley Field Laboratory during a preliminary investigation of the problem of applying fuel injection and compression ignition to aircraft engines. For this work a standard Liberty Engine cylinder was fitted with a high compression, 11.4 : 1 compression ratio, piston, and equipped with an airless injection system, including a primary fuel pump, an injection pump, and an automatic injection valve. The results obtained during this investigation have indicated the possibility of applying airless injection and compression ignition to a cylinder of this size, 8-inch bore by 7-inch stroke, when operating at engine speeds as high as 1,850 R. P. M. A minimum specific fuel consumption with diesel engine fuel oil of 0.30 pound per I. HP. Hour was obtained when developing about 16 B. HP. At 1,730 R. P. M.
Paenibacillus segetis sp. nov., isolated from soil of a tropical rainforest.
Huang, Huiqin; Feng, Fengzhao; Liu, Min; Zhang, Fute; Sun, Qianguang; Qin, Songyu; Bao, Shixiang
2016-09-01
A Gram-stain-positive, facultatively anaerobic, endospore-forming, irregular rod-shaped bacterium, designated DB13260T, was isolated from tropical rainforest soil in Jianfengling Nature Reserve in Hainan, China. The isolate was found to grow with 0-4 % (w/v) NaCl, at 5-40 °C and pH 6.0-10.5, with an optimum of 0 % NaCl, 30-37 °C and pH 8.5-9.0, respectively. The predominant isoprenoid quinone was menaquinone 7 (MK-7), and the major fatty acids were anteiso-C15 : 0, iso-C16 : 0 and C16 : 0. The G+C content of the genomic DNA was 53.7 mol%. Analysis of the 16S rRNA gene sequence of strain DB13260T showed an affiliation of the strain with the genus Paenibacillus, sharing 98.3 % and 97.8 % 16S rRNA gene sequence similarities with the closest relatives Paenibacillus anaericanus MH21T and Paenibacillus selenii W126T, respectively. The DNA-DNA hybridization values between strain DB13260T and the two type strains were 60.4 % and 42.6 %, respectively. The combined phenotypic and DNA-DNA hybridization data supported the conclusion that strain DB13260T represents a novel species of the genus Paenibacillus, for which the name Paenibacillussegetis sp. nov. is proposed. The type strain is DB13260T (=CGMCC 1.12769T=DSM 28014T).
NASA Astrophysics Data System (ADS)
He, Jing; Wen, Xuejie; Chen, Ming; Chen, Lin
2015-09-01
In this paper, a Golay complementary training sequence (TS)-based symbol synchronization scheme is proposed and experimentally demonstrated in multiband orthogonal frequency division multiplexing (MB-OFDM) ultra-wideband over fiber (UWBoF) system with a variable rate low-density parity-check (LDPC) code. Meanwhile, the coding gain and spectral efficiency in the variable rate LDPC-coded MB-OFDM UWBoF system are investigated. By utilizing the non-periodic auto-correlation property of the Golay complementary pair, the start point of LDPC-coded MB-OFDM UWB signal can be estimated accurately. After 100 km standard single-mode fiber (SSMF) transmission, at the bit error rate of 1×10-3, the experimental results show that the short block length 64QAM-LDPC coding provides a coding gain of 4.5 dB, 3.8 dB and 2.9 dB for a code rate of 62.5%, 75% and 87.5%, respectively.
On the Use of 3dB Qualification Margin for Structural Parts on Expendable Launch Vehicles
NASA Technical Reports Server (NTRS)
Yunis, Isam
2007-01-01
The standard random vibration qualification test used for Expendable Launch Vehicle components is Maximum Predicted Environment (MPE) + 6dB for a duration of 4 times the service life of the part. This can be a severe qualification test for these fatigue-sensitive structures. This paper uses flight data from several launch vehicles to establish that reducing the qualification approach to MPE+3dB for the duration of the peak environment (1x life) is valid for fatigue-sensitive structural components. Items that can be classified as fatigue-sensitive are probes, ducts, tubing, bellows, hoses, and any non-functional structure. Non-functional structure may be flight critical or carry fluid, but it cannot include any moving parts or electronics. This reduced qualification approach does not include primary or secondary structure which would be exclusively designed by peak loads, either transient or quasi-static, that are so large and of so few cycles as to make fatigue a moot point.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zuur, Charlotte L.; Simis, Yvonne J.; Lamers, Emmy A.
2009-06-01
Purpose: Radiotherapy (RT) is a common treatment of head-and-neck carcinoma. The objective of this study was to perform a prospective multivariate assessment of the dose-effect relationship between intensity-modulated RT and hearing loss. Methods and Materials: Pure tone audiometry at 0.250-16 kHz was obtained before and after treatment in 101 patients (202 ears). All patients received full-course intensity-modulated RT (range, 56-70 Gy), with a median cochlear dose of 11.4 Gy (range, 0.2-69.7). Results: Audiometry was performed 1 week before and a median of 9 weeks (range, 1-112) after treatment. The mean hearing deterioration at pure tone average air-conduction 1-2-4 kHz wasmore » small (from 28.6 dB HL to 30.1 dB HL). However, individual patients showed clinically significant hearing loss, with 10-dB threshold shift incidences of 13% and 18% at pure tone averages air-conduction 1-2-4 kHz and 8-10-12.5 kHz, respectively. Post-treatment hearing capability was unfavorable in the case of greater inner ear radiation doses (p <0.0001), unfavorable baseline hearing capability (p <0.0001), green-eyed patients (p <0.0001), and older age (p <0.0001). Using multivariate analysis, a prediction of individual hearing capabiltity after treatment was made. Conclusion: RT-induced hearing loss in the mean population is modest. However, clinically significant hearing loss was observed in older patients with green eyes and unfavorable pretreatment hearing. In these patients, the intended radiation dose may be adjusted according to the proposed predictive model, aiming to decrease the risk of ototoxicity.« less
Lattimer, C R; Kalodiki, E; Azzam, M; Geroulakos, G
2016-07-01
To test the in vivo haemodynamic performance of graduated elastic compression (GEC) stockings using air-plethysmography (APG) in healthy volunteers (controls) and patients with varicose veins (VVs), post-thrombotic syndrome (PTS), or lymphoedema. Responsiveness data were used to determine which group benefited the most from GEC. There were 12 patients per group compared using no compression, knee-length Class 1 (18-21 mmHg) compression, and Class 2 (23-32 mmHg) compression. Stocking/leg interface pressures (mmHg) were measured supine in two places using an air-sensor transducer. Stocking performance parameters, investigated before and after GEC, included the standard APG tests (working venous volume [wVV], venous filling index [VFI], venous drainage index [VDI], ejection fraction [EF]) and the occlusion plethysmography tests (incremental pressure causing the maximal increase in calf volume [IPMIV], outflow fraction [OF]). Results were expressed as median and interquartile range. Significant graduated compression was achieved in all four groups with higher interface pressures at the ankle. Only the VVs patients had a significant reduction in their wVV (without: 133 [109-146] vs. class1: 93 [74-113] mL) and the VFI (without: 4.6 [3-7.1] vs. class1: 3.1 [1.9-5] mL/s), both at p <.05. The IPMIV improved significantly in all groups except in the PTS group (p <.05). The OF improved only in the controls (without: 43 [38-51] vs. class1: 50 [48-53] %) and the VVs patients (without: 47 [39-58] vs. class1: 56 [50-64] %), both at p <.05. There were no significant differences in the VDI or the EF with GEC. Compression dose-response relationships were not observed. Patients with varicose veins improved the most, whereas those with PTS improved the least. Performance seemed to depend more on disease pathophysiology than compression strength. However, the lack of responsiveness to compression strength may be related to the low external pressures used. Stocking performance tests may have value in selecting those patients who benefit most from compression. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Automating RPM Creation from a Source Code Repository
2012-02-01
apps/usr --with- libpq=/apps/ postgres make rm -rf $RPM_BUILD_ROOT umask 0077 mkdir -p $RPM_BUILD_ROOT/usr/local/bin mkdir -p $RPM_BUILD_ROOT...from a source code repository. %pre %prep %setup %build ./autogen.sh ; ./configure --with-db=/apps/db --with-libpq=/apps/ postgres make
Hains, Guy; Boucher, Pierre B; Lamy, Anne-Marie
2015-03-01
The aim of this study was to evaluate the efficacy of myofascial therapy involving ischemic compression on trigger points in combination with mobilization therapy on patients with chronic nonspecific foot pain. Two quasi-experimental before-and-after studies involving two different baseline states. Foot pain patients at a private clinic were divided into two separate cohorts: A, custom orthotic users; and B, non-users. In Study A, 31 users received 15 experimental treatments consisting of ischemic compressions on trigger points and mobilization of articulations through the foot immediately after study enrollment. In study B, ten non-users were prescribed a soft prefabricated insole and were monitored for five weeks before subsequently receiving 15 experimental treatments after the initial five-week delay. The Foot Function Index (FFI) and patients' perceived improvement score (PIS) on a scale from 0% to 100%. The Study A group (n=31) maintained a significant reduction in the FFI at all three follow-up evaluations. Mean improvement from baseline in FFI was 47%, 49% and 56% at 0, 1 and 6 months, respectively, post-treatment. Mean PIS was 58%, 57%, and 58%, again at 0, 1 and 6 months post-treatment. For the Study B group, mean improvement in FFI was only 19% after the monitoring period, and 64% after the experimental treatment period. Mean PIS was 31% after monitoring, and 78% after experimental treatment. In repeated measures analyses, experimental treatment was associated with a significant main effect in both of these before-and after studies (all P values<0.01). Combined treatment involving ischemic compression and joint mobilization for chronic foot pain is associated with significant improvements in functional and self-perceived improvement immediately and at up to six-months post-treatment. Further validation of this treatment approach within a randomized controlled trial is needed.
NASA Technical Reports Server (NTRS)
Chen, J. H.; Chong, M. S.; Soria, J.; Sondergaard, R.; Perry, A. E.; Rogers, M.; Moser, R.; Cantwell, B. J.
1990-01-01
A preliminary investigation of the geometry of flow patterns in numerically simulated compressible and incompressible mixing layers was carried out using 3-D critical point methodology. Motions characterized by high rates of kinetic energy dissipation and/or high enstrophy were of particular interest. In the approach the partial derivatives of the velocity field are determined at every point in the flow. These are used to construct the invariants of the velocity gradient tensor and the rate-of-strain tensor (P, Q, R, and P(sub s), Q(sub s), R(sub s) respectively). For incompressible flow the first invariant is zero. For the conditions of the compressible simulation, the first invariant is found to be everywhere small, relative to the second and third invariants, and so in both cases the local topology at a point is mainly determined by the second and third invariants. The data at every grid point is used to construct scatter plots of Q versus R and Q(sub s) versus R(sub s). Most points map to a cluster near the origin in Q-R space. However, fine scale motions, that is motions which are characterized by velocity derivatives which scale with the square root of R(sub delta), tend to map to regions which lie far from the origin. Definite trends are observed for motions characterized by high enstrophy and/or high dissipation. The observed trends suggest that, for these motions, the second and third invariants of the velocity gradient and rate-of-strain tensors are strongly correlated. The second and third invariants of the rate-of-strain tensor are related by K(-Q(sub s))(exp 3/2), which is consistent with the above scaling of velocity derivatives. The quantity K appears to depend on Reynolds number with an upper limit K = 2(the square root of 3)/9 corresponding to locally axisymmetric flow. For both the compressible and incompressible mixing layer, regions corresponding to high rates of dissipation are found to be characterized by comparable magnitudes of R(sub ij)R(sub ij) and S(sub ij)S(sub ij). For the incompressible mixing layer, regions characterized by the highest values of enstrophy are found to have relatively low strain rates.
Salehi, Forouz; Hosseini-Zare, Mahshid S; Aghajani, Haleh; Seyedi, Seyedeh Yalda; Hosseini-Zare, Maryam S; Sharifzadeh, Mohammad
2017-08-01
The aim of this study was to determine the effects of cyclic adenosine monophosphate (cAMP) and its dependent pathway on thermal nociception in a mouse model of acute pain. Here, we studied the effect of H-89 (protein kinase A inhibitor), bucladesine (Db-cAMP) (membrane-permeable analog of cAMP), and pentoxifylline (PTX; nonspecific phosphodiesterase (PDE) inhibitor) on pain sensation. Different doses of H-89 (0.05, 0.1, and 0.5 mg/100 g), PTX (5, 10, and 20 mg/100 g), and Db-cAMP (50, 100, and 300 nm/mouse) were administered intraperitoneally (I.p.) 15 min before a tail-flick test. In combination groups, we injected the first and the second compounds 30 and 15 min before the tail-flick test, respectively. I.p. administration of H-89 and PTX significantly decreased the thermal-induced pain sensation in their low applied doses. Db-cAMP, however, decreased the pain sensation in a dose-dependent manner. The highest applied dose of H-89 (0.5 mg/100 g) attenuated the antinociceptive effect of Db-cAMP in doses of 50 and 100 nm/mouse. Surprisingly, Db-cAMP decreased the antinociceptive effect of the lowest dose of H-89 (0.05 mg/100 g). All applied doses of PTX reduced the effect of 0.05 mg/100 g H-89 on pain sensation; however, the highest dose of H-89 compromised the antinociceptive effect of 20 mg/100 g dose of PTX. Co-administration of Db-cAMP and PTX increased the antinociceptive effect of each compound on thermal-induced pain. In conclusion, PTX, H-89, and Db-cAMP affect the thermal-induced pain by probably interacting with intracellular cAMP and cGMP signaling pathways and cyclic nucleotide-dependent protein kinases. © 2017 Société Française de Pharmacologie et de Thérapeutique.
Austin, Andrea L; Spalding, Carmen N; Landa, Katrina N; Myer, Brian R; Donald, Cure; Smith, Jason E; Platt, Gerald; King, Heather C
2017-10-27
In effort to improve chest compression quality among health care providers, numerous feedback devices have been developed. Few studies, however, have focused on the use of cardiopulmonary resuscitation feedback devices for infants and children. This study evaluated the quality of chest compressions with standard team-leader coaching, a metronome (MetroTimer by ONYX Apps), and visual feedback (SkillGuide Cardiopulmonary Feedback Device) during simulated infant cardiopulmonary resuscitation. Seventy voluntary health care providers who had recently completed Pediatric Advanced Life Support or Basic Life Support courses were randomized to perform simulated infant cardiopulmonary resuscitation into 1 of 3 groups: team-leader coaching alone (control), coaching plus metronome, or coaching plus SkillGuide for 2 minutes continuously. Rate, depth, and frequency of complete recoil during cardiopulmonary resuscitation were recorded by the Laerdal SimPad device for each participant. American Heart Association-approved compression techniques were randomized to either 2-finger or encircling thumbs. The metronome was associated with more ideal compression rate than visual feedback or coaching alone (104/min vs 112/min and 113/min; P = 0.003, 0.019). Visual feedback was associated with more ideal depth than auditory (41 mm vs 38.9; P = 0.03). There were no significant differences in complete recoil between groups. Secondary outcomes of compression technique revealed a difference of 1 mm. Subgroup analysis of male versus female showed no difference in mean number of compressions (221.76 vs 219.79; P = 0.72), mean compression depth (40.47 vs 39.25; P = 0.09), or rate of complete release (70.27% vs 64.96%; P = 0.54). In the adult literature, feedback devices often show an increase in quality of chest compressions. Although more studies are needed, this study did not demonstrate a clinically significant improvement in chest compressions with the addition of a metronome or visual feedback device, no clinically significant difference in Pediatric Advanced Life Support-approved compression technique, and no difference between compression quality between genders.
Jin, Shasha; Chang, Cuiqing; Zhang, Lantao; Liu, Yang; Huang, Xianren; Chen, Zhimin
2015-01-01
The aim of this study was to examine the effects of chlorogenic acid (CGA) on glucose and lipid metabolism in late diabetic db/db mice, as well as on adiponectin receptors and their signaling molecules, to provide evidence for CGA in the prevention of type 2 diabetes. We randomly divided 16 female db/db mice into db/db-CGA and db/db-control (CON) groups equally; db/m mice were used as control mice. The mice in both the db/db-CGA and db/m-CGA groups were administered 80 mg/kg/d CGA by lavage for 12 weeks, whereas the mice in both CON groups were given equal volumes of phosphate-buffered saline (PBS) by lavage. At the end of the intervention, we assessed body fat and the parameters of glucose and lipid metabolism in the plasma, liver and skeletal muscle tissues as well as the levels of aldose reductase (AR) and transforming growth factor-β1 (TGF-β1) in the kidneys and measured adiponectin receptors and the protein expression of their signaling molecules in liver and muscle tissues. After 12 weeks of intervention, compared with the db/db-CON group, the percentage of body fat, fasting plasma glucose (FPG) and glycosylated hemoglobin (HbA1c) in the db/db-CGA group were all significantly decreased; TGF-β1 protein expression and AR activity in the kidney were both decreased; and the adiponectin level in visceral adipose was increased. The protein expression of adiponectin receptors (ADPNRs), the phosphorylation of AMP-activated protein kinase (AMPK) in the liver and muscle, and the mRNA and protein levels of peroxisome proliferator-activated receptor alpha (PPAR-α) in the liver were all significantly greater. CGA could lower the levels of fasting plasma glucose and HbA1c during late diabetes and improve kidney fibrosis to some extent through the modulation of adiponectin receptor signaling pathways in db/db mice. PMID:25849026
NASA Technical Reports Server (NTRS)
Seller, J.
1985-01-01
The inertial pointing stability of a gimbal pointing system (AGS) was compared with a magnetic pointing/gimbal followup system (ASPS), under certain conditions of system structural flexibility and disturbance inputs from the gimbal support structure. Separate 3 degree-of-freedom (3DOF) linear models based on NASTRAN modal flexibility data for the gimbal and support structures were generated for the ASPS configurations. Using the models inertial pointing control loops providing 6dB of gain margin and 45 deg of phase margin were defined for each configuration. The pointing loop bandwidth obtained for the ASPS is more than twice the level achieved for the AGS configuration. The AGS limit is attributed to the gimbal and support structure flexibility. As a result of the higher ASPS pointing loop bandwidth and the disturbance rejection provided by the magnetic isolation ASPS pointing performane is significantly better than that of the AGS system. The low frequency peak of the ASPS transfer function from base disturbance to payload angular motion is almost 60dB lower than AGS low frequency peak.
Kubo, Fumiyo; Miyatsuka, Takeshi; Sasaki, Shugo; Takahara, Mitsuyoshi; Yamamoto, Yuichi; Shimo, Naoki; Watada, Hirotaka; Kaneto, Hideaki; Gannon, Maureen; Matsuoka, Taka-aki; Shimomura, Iichiro
2017-01-01
Glucagon-like peptide 1 (GLP-1) has been shown to play important roles in maintaining β-cell functions, such as insulin secretion and proliferation. While expression levels of GLP-1 receptor (Glp1r) are compromised in the islets of diabetic rodents, it remains unclear when and to what degree Glp1r mRNA levels are decreased during the progression of diabetes. In this study, we performed real-time PCR with the islets of db/db diabetic mice at different ages, and found that the expression levels of Glp1r were comparable to those of the islets of nondiabetic db/misty controls at the age of four weeks, and were significantly decreased at the age of eight and 12 weeks. To investigate whether restored expression of Glp1r affects the diabetic phenotypes, we generated the transgenic mouse model Pdx1PB-CreER™; CAG-CAT-Glp1r (βGlp1r) that allows for induction of Glp1r expression specifically in β cells. Whereas the expression of exogenous Glp1r had no measurable effect on glucose tolerance in nondiabetic βGlp1r;db/misty mice, βGlp1r;db/db mice exhibited higher glucose and lower insulin levels in blood on glucose challenge test than control db/db littermates. In contrast, four weeks of treatment with exendin-4 improved the glucose profiles and increased serum insulin levels in βGlp1r;db/db mice, to significantly higher levels than those in control db/db mice. These differential effects of exogenous Glp1r in nondiabetic and diabetic mice suggest that downregulation of Glp1r might be required to slow the progression of β-cell failure under diabetic conditions. PMID:26854076
Liu, Xilin; Zhang, Milin; Xiong, Tao; Richardson, Andrew G; Lucas, Timothy H; Chin, Peter S; Etienne-Cummings, Ralph; Tran, Trac D; Van der Spiegel, Jan
2016-07-18
Reliable, multi-channel neural recording is critical to the neuroscience research and clinical treatment. However, most hardware development of fully integrated, multi-channel wireless neural recorders to-date, is still in the proof-of-concept stage. To be ready for practical use, the trade-offs between performance, power consumption, device size, robustness, and compatibility need to be carefully taken into account. This paper presents an optimized wireless compressed sensing neural signal recording system. The system takes advantages of both custom integrated circuits and universal compatible wireless solutions. The proposed system includes an implantable wireless system-on-chip (SoC) and an external wireless relay. The SoC integrates 16-channel low-noise neural amplifiers, programmable filters and gain stages, a SAR ADC, a real-time compressed sensing module, and a near field wireless power and data transmission link. The external relay integrates a 32 bit low-power microcontroller with Bluetooth 4.0 wireless module, a programming interface, and an inductive charging unit. The SoC achieves high signal recording quality with minimized power consumption, while reducing the risk of infection from through-skin connectors. The external relay maximizes the compatibility and programmability. The proposed compressed sensing module is highly configurable, featuring a SNDR of 9.78 dB with a compression ratio of 8×. The SoC has been fabricated in a 180 nm standard CMOS technology, occupying 2.1 mm × 0.6 mm silicon area. A pre-implantable system has been assembled to demonstrate the proposed paradigm. The developed system has been successfully used for long-term wireless neural recording in freely behaving rhesus monkey.
Comparison of direct and heterodyne detection optical intersatellite communication links
NASA Technical Reports Server (NTRS)
Chen, C. C.; Gardner, C. S.
1987-01-01
The performance of direct and heterodyne detection optical intersatellite communication links are evaluated and compared. It is shown that the performance of optical links is very sensitive to the pointing and tracking errors at the transmitter and receiver. In the presence of random pointing and tracking errors, optimal antenna gains exist that will minimize the required transmitter power. In addition to limiting the antenna gains, random pointing and tracking errors also impose a power penalty in the link budget. This power penalty is between 1.6 to 3 dB for a direct detection QPPM link, and 3 to 5 dB for a heterodyne QFSK system. For the heterodyne systems, the carrier phase noise presents another major factor of performance degradation that must be considered. In contrast, the loss due to synchronization error is small. The link budgets for direct and heterodyne detection systems are evaluated. It is shown that, for systems with large pointing and tracking errors, the link budget is dominated by the spatial tracking error, and the direct detection system shows a superior performance because it is less sensitive to the spatial tracking error. On the other hand, for systems with small pointing and tracking jitters, the antenna gains are in general limited by the launch cost, and suboptimal antenna gains are often used in practice. In which case, the heterodyne system has a slightly higher power margin because of higher receiver sensitivity.
The impact of dysfunctional breathing on the assessment of asthma control.
Veidal, Sandra; Jeppegaard, Maria; Sverrild, Asger; Backer, Vibeke; Porsbjerg, Celeste
2017-02-01
Dysfunctional breathing (DB) is a respiratory disorder, which involves a pattern of breathing too deeply, too superficially and/or too rapidly. In asthma patients, DB may lead to an overestimation of the severity of asthma symptoms, and hence potentially to overtreatment. However, it is not known to which degree DB may affect estimates of asthma control, in a specialist clinical setting. The MAPOut-study examined all patients referred consecutively over a 12-months period for specialist assessment of asthma at the Respiratory Outpatient Clinic at Bispebjerg Hospital in Copenhagen. All patients were examined with the Nijmegen questionnaire with a DB defined as a score ≥23 and the ACQ questionnaire. Linear regression analysis of predictors of ACQ score was performed. Asthma was defined as asthma symptoms and a positive asthma test. Of the 256 patients referred to the lung clinic, data on both the Nijmegen questionnaire and ACQ score was obtained in 127 patients, who were included in the present analysis. Median (range) age: 30 (15-63) years, and 76 (59.8%) were females. DB was found in 31 (24.4%). Asthmatic patients with co-existing DB had a poorer asthma control compared to asthmatics without DB (Median (range) ACQ score: 2.40 (0.20-4.60) vs 1.20 (0.00-4.40); p < 0.001.). A regression analysis showed that the effect of DB on asthma control was independent of airway hyperresponsiveness or airway inflammation in patients with DB. Dysfunctional breathing is common among asthma patients in a specialist setting, and results in a clinically significant underestimation of asthma control, which may potentially lead to overtreatment. Copyright © 2016 Elsevier Ltd. All rights reserved.
Development for a supercompact X -band pulse compression system and its application at SLAC
Wang, Juwen W.; Tantawi, Sami G.; Xu, Chen; ...
2017-11-09
Here, we have successfully designed, fabricated, installed, and tested a super compact X -band SLAC Energy Doubler system at SLAC. It is composed of an elegant 3 dB coupler–mode converter–polarizer coupled to a single spherical energy storage cavity with high Q 0 of 94000 and a diameter less than 12 cm. The available rf peak power of 50 MW can be compressed to a peak average power of more than 200 MW in order to double the kick for the electron bunches in a rf transverse deflector system and greatly improve the measurement resolution of both the electron bunches andmore » the x-ray free-electron laser pulses. The design physics and fabrication as well as the measurement results will be presented in detail. High-power operation has demonstrated the excellent performance of this rf compression system without rf breakdown, sign of pulse heating, and rf radiation.« less
Development for a supercompact X -band pulse compression system and its application at SLAC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Juwen W.; Tantawi, Sami G.; Xu, Chen
Here, we have successfully designed, fabricated, installed, and tested a super compact X -band SLAC Energy Doubler system at SLAC. It is composed of an elegant 3 dB coupler–mode converter–polarizer coupled to a single spherical energy storage cavity with high Q 0 of 94000 and a diameter less than 12 cm. The available rf peak power of 50 MW can be compressed to a peak average power of more than 200 MW in order to double the kick for the electron bunches in a rf transverse deflector system and greatly improve the measurement resolution of both the electron bunches andmore » the x-ray free-electron laser pulses. The design physics and fabrication as well as the measurement results will be presented in detail. High-power operation has demonstrated the excellent performance of this rf compression system without rf breakdown, sign of pulse heating, and rf radiation.« less
NASA Astrophysics Data System (ADS)
Zhu, Zhenyu; Wang, Jianyu
1996-11-01
In this paper, two compression schemes are presented to meet the urgent needs of compressing the huge volume and high data rate of imaging spectrometer images. According to the multidimensional feature of the images and the high fidelity requirement of the reconstruction, both schemes were devised to exploit the high redundancy in both spatial and spectral dimension based on the mature wavelet transform technology. Wavelet transform was applied here in two ways: First, with the spatial wavelet transform and the spectral DPCM decorrelation, a ratio up to 84.3 with PSNR > 48db's near-lossless result was attained. This is based ont he fact that the edge structure among all the spectral bands are similar while WT has higher resolution in high frequency components. Secondly, with the wavelet's high efficiency in processing the 'wideband transient' signals, it was used to transform the raw nonstationary signals in the spectral dimension. A good result was also attained.
Validation of the UNC OCT Index for the Diagnosis of Early Glaucoma
Lee, Gary; Budenz, Donald L.; Warren, Joshua L.; Wall, Michael; Artes, Paul H.; Callan, Thomas M.; Flanagan, John G.
2018-01-01
Purpose To independently validate the performance of the University of North Carolina Optical Coherence Tomography (UNC OCT) Index in diagnosing and predicting early glaucoma. Methods Data of 118 normal subjects (118 eyes) and 96 subjects (96 eyes) with early glaucoma defined as visual field mean deviation (MD) greater than −4 decibels (dB), aged 40 to 80 years, and who were enrolled in the Full-Threshold Testing Size III, V, VI comparison study were used in this study. CIRRUS OCT average and quadrants' retinal nerve fiber layer (RNFL); optic disc vertical cup-to-disc ratio (VCDR), cup-to-disc area ratio, and rim area; and average, minimum, and six sectoral ganglion cell-inner plexiform layer (GCIPL) measurements were run through the UNC OCT Index algorithm. Area under the receiver operating characteristic curve (AUC) and sensitivities at 95% and 99% specificity were calculated and compared between single parameters and the UNC OCT Index. Results Mean age was 60.1 ± 11.0 years for normal subjects and 66.5 ± 8.1 years for glaucoma patients (P < 0.001). MD was 0.29 ± 1.04 dB and −1.30 ± 1.35 dB in normal and glaucomatous eyes (P < 0.001), respectively. The AUC of the UNC OCT Index was 0.96. The best single metrics when compared to the UNC OCT Index were VCDR (0.93, P = 0.054), average RNFL (0.92, P = 0.014), and minimum GCIPL (0.91, P = 0.009). The sensitivities at 95% and 99% specificity were 85.4% and 76.0% (UNC OCT Index), 71.9% and 62.5% (VCDR, all P < 0.001), 64.6% and 53.1% (average RNFL, all P < 0.001), and 66.7% and 58.3% (minimum GCIPL, all P < 0.001), respectively. Conclusions The findings confirm that the UNC OCT Index may provide improved diagnostic perforce over that of single OCT parameters and may be a good tool for detection of early glaucoma. Translational Relevance The UNC OCT Index algorithm may be incorporated easily into routine clinical practice and be useful for detecting early glaucoma. PMID:29629238
Validation of the UNC OCT Index for the Diagnosis of Early Glaucoma.
Mwanza, Jean-Claude; Lee, Gary; Budenz, Donald L; Warren, Joshua L; Wall, Michael; Artes, Paul H; Callan, Thomas M; Flanagan, John G
2018-04-01
To independently validate the performance of the University of North Carolina Optical Coherence Tomography (UNC OCT) Index in diagnosing and predicting early glaucoma. Data of 118 normal subjects (118 eyes) and 96 subjects (96 eyes) with early glaucoma defined as visual field mean deviation (MD) greater than -4 decibels (dB), aged 40 to 80 years, and who were enrolled in the Full-Threshold Testing Size III, V, VI comparison study were used in this study. CIRRUS OCT average and quadrants' retinal nerve fiber layer (RNFL); optic disc vertical cup-to-disc ratio (VCDR), cup-to-disc area ratio, and rim area; and average, minimum, and six sectoral ganglion cell-inner plexiform layer (GCIPL) measurements were run through the UNC OCT Index algorithm. Area under the receiver operating characteristic curve (AUC) and sensitivities at 95% and 99% specificity were calculated and compared between single parameters and the UNC OCT Index. Mean age was 60.1 ± 11.0 years for normal subjects and 66.5 ± 8.1 years for glaucoma patients ( P < 0.001). MD was 0.29 ± 1.04 dB and -1.30 ± 1.35 dB in normal and glaucomatous eyes ( P < 0.001), respectively. The AUC of the UNC OCT Index was 0.96. The best single metrics when compared to the UNC OCT Index were VCDR (0.93, P = 0.054), average RNFL (0.92, P = 0.014), and minimum GCIPL (0.91, P = 0.009). The sensitivities at 95% and 99% specificity were 85.4% and 76.0% (UNC OCT Index), 71.9% and 62.5% (VCDR, all P < 0.001), 64.6% and 53.1% (average RNFL, all P < 0.001), and 66.7% and 58.3% (minimum GCIPL, all P < 0.001), respectively. The findings confirm that the UNC OCT Index may provide improved diagnostic perforce over that of single OCT parameters and may be a good tool for detection of early glaucoma. The UNC OCT Index algorithm may be incorporated easily into routine clinical practice and be useful for detecting early glaucoma.
Numerical simulation of the compressible Orszag-Tang vortex. II. Supersonic flow. Interim report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Picone, J.M.; Dahlburg, R.B.
The numerical investigation of the Orszag-Tang vortex system in compressible magnetofluids will consider initial conditions with embedded supersonic regions. The simulations have initial average Mach numbers M = 1.0 and 1.5 and beta = 10/3 with Lundquist numbers S = 50, 100, or 200. The behavior of the system differs significantly from that found previously for the incompressible and subsonic analogs. Shocks form at the downstream boundaries of the embedded supersonic regions outside the central magnetic X-point and produce strong local current sheets which dissipate appreciable magnetic energy. Reconnection at the central X-point, which dominates the incompressible and subsonic systems,more » peaks later and has a smaller impact as M increases from 0.6 to 1.5. Similarly, correlation between the momentum and magnetic field begins significant growth later than in subsonic and incompressible flows. The shocks bound large compression regions, which dominate the wavenumber spectra of autocorrelations in mass density, velocity, and magnetic field.« less
NASA Technical Reports Server (NTRS)
Arbeille, P.; Berson, M.; Blondeau, B.; Durand, A.; Bodard, S.; Locatelli, A.; Fox, G. E. (Principal Investigator)
1995-01-01
The object of this study was to define and validate a non-invasive method of evaluation and monitoring of vascular resistances in the leg. Blood flow velocity was measured by Doppler ultrasound in an animal model (ewe) with similar blood flow characteristics in the lower limb as man and allowing access to the required invasive measurements for validation of the method (pressure and flow). Vascular resistances distal to the measuring point (femoral, for example) were assessed using the resistance index R = D/S, S being the peak systolic deflection and D that of diastolic reflux of the Doppler spectral analysis of flow in the femoral artery. The values and variations of this resistance index were compared with the vascular resistances calculated from measurements of pressure and flow at the point of Doppler sampling and expressed in mmHg/ml/min. Femoral flow was measured by Doppler ultrasound (Doppler-echo), and mean pressure by an arterial catheter introduced into the abdominal aorta. Compression of the lower limb veins induced a venous return resulting in a reduction of cardiac output and femoral flow. During compression, femoral flow decreased by an average of 29% (p < 0.001) although mean pressure and heart rate did not change significantly. The femoral resistance index (Rf) increased by an average of 37.5% (p < 0.01) and vascular resistances increased by 45.9% (p < 0.01). Injection of 1 mg adrenaline induced peripheral vasoconstriction with an increase in blood pressure and a decrease in heart rate and femoral flow.(ABSTRACT TRUNCATED AT 250 WORDS).
[Effect of nano-hydroxyapatite to glass ionomer cement].
Mu, Ya-Bing; Zang, Guang-Xiang; Sun, Hong-Chen; Wang, Cheng-Kun
2007-12-01
To investigate the mechanical character, microleakage and mineralizing potential of nano-hydroxyapatite (nano-HAP)-added glass ionomer cement(GIC). 8% nano-HAP were incorporated into GIC as composite, and pure GIC as control. Both types of material were used to make 20 cylinders respectively in order to detect three-point flexural strength and compressive strength. Class V cavities were prepared in 120 molars extracted for orthodontic treatment, then were filled by two kinds of material. The microleakage at the composite-dentine interface was observed with confocal laser scanning microscope (CLSM) after stained with 1% rhodamin-B-isothiocyanate for 24 hours. Class V cavities were prepared in the molars of 4 healthy dogs, filled with composite, and the same molars in the other side were filled with GIC as control. The teeth were extracted to observe the mineralizing property with polarimetric microscope in 8 weeks after filling. Three-point flexural strength and compressive of nano-HAP-added GIC were increased compared with pure GIC (P < 0.001, P < 0.05). The nanoleakages and microleakages appeared at the material-dentine interface in the two groups, but there were more microleakages in control group than in experiment group (P = 0.004). New crystals of hydroxyapatite were formed into a new mineralizing zone at the interface of tooth and nano-HAP-added GIC, while there was no hydroxyapatite crystals formed at the interface of tooth and pure GIC. 8% nano-HAP-added GIC can tightly fill tooth and have mineralizing potential, and can be used as liner or filling material for prevention.
Lam, Tze Yan; Seto, Sai Wang; Lau, Yee Man; Au, Lai Shan; Kwan, Yiu Wa; Ngai, Sai Ming; Tsui, Kwong Wing
2006-09-28
In this study, we compared the endothelium-dependent and -independent relaxation of the isolated thoracic aorta of control (+db/+m) and diabetic (+db/+db) (C57BL/KsJ) mice. The gene expression (mRNA and protein) level of the muscarinic M(3) receptors, endothelial nitric oxide synthase (eNOS) and caveolin-1 of the aorta was also evaluated. Acetylcholine caused a concentration-dependent, N(G)-nitro-L-arginine methyl-ester (20 microM)-sensitive relaxation, with approximately 100% relaxation at 10 microM, in +db/+m mice. In +db/+db mice, the acetylcholine-induced relaxation was significantly smaller (maximum relaxation: approximately 80%). The sodium nitroprusside-mediated relaxation was slightly diminished in +db/+db mice, compared to +db/+m mice. However, there was no significant difference in the isoprenaline- and cromakalim-induced relaxation observed in both species. The mRNA and protein expression levels of caveolin-1 were significantly higher in the aorta of +db/+db mice. In contrast, there was no difference in the mRNA and protein expression levels of eNOS and muscarinic M(3) receptors between these mice. Our results demonstrate that the impairment of the acetylcholine-induced, endothelium-dependent aortic relaxation observed in +db/+db mice was probably associated with an enhanced expression of caveolin-1 mRNA and protein.
NASA Astrophysics Data System (ADS)
Matsumoto, Atsushi; Matsushita, Asuka; Takei, Yuki; Akahane, Kouichi; Matsushima, Yuichi; Ishikawa, Hiroshi; Utaka, Katsuyuki
2014-09-01
In this study, we investigated quantum dot intermixing (QDI) for InAs/InGaAlAs highly stacked QDs on an InP(311)B substrate with low-temperature annealing at 650 °C in order to realize integrated photonic devices with QDs and passive waveguides. In particular, we adopted the method of introducing point defects by ICP-RIE to realize a blue shift of the PL peak wavelength by about 150 nm. Moreover, we successfully fabricated double micro-ring resonators by QDI. The output power contrasts of the devices were found to be 9.0 and 8.6 dB for TE and TM modes, respectively.
Chen, Yi-Chen; Lee, Ya-Yun; Pai, Sheng-Fang; Yang, Shue-Fen
2009-05-01
The prevalence of extra distolingual (DL) roots in mandibular first molars in Chinese population is about 20%. The purpose of this study was to evaluate the difference of root length and root curvatures between distobuccal (DB) and DL roots of three-rooted mandibular first molars in a Taiwanese (Chinese) population. Of the 293 extracted mandibular first molars, DL roots were present in 29 (9.9%) teeth. Excluding teeth with fractured DB or DL roots, 21 mandibular first molars were further investigated. DB and DL root lengths were measured from the lower level of furcation at the distal surface to the root apex. The curvature of the DL root was measured on mesial-distal and buccal-lingual radiographs by Schneider's technique. The DL roots were significantly (p < 0.001) shorter than the DB roots with an average of 1.48 +/- 0.81 mm. Most DL roots had a greater curvature in a buccal-lingual orientation (36.35 degrees +/- 9.38 degrees ) than a mesial-distal orientation (9.24 degrees +/- 6.10 degrees ) and 28.57% of the curved DL roots had the curvature at the apical one third (p < 0.001). The results of this study verified the characteristics of shorter root length and severe buccal-lingual inclination of DL roots in three-rooted mandibular first molars.
Effect of Ezetimibe on Insulin Secretion in db/db Diabetic Mice
Zhong, Yong; Wang, Jun; Gu, Ping; Shao, Jiaqing; Lu, Bin; Jiang, Shisen
2012-01-01
Objective. To investigate the effect of ezetimibe on the insulin secretion in db/db mice. Methods. The db/db diabetic mice aged 8 weeks were randomly assigned into 2 groups and intragastrically treated with ezetimibe or placebo for 6 weeks. The age matched db/m mice served as controls. At the end of experiment, glucose tolerance test was performed and then the pancreas was collected for immunohistochemistry. In addition, in vitro perfusion of pancreatic islets was employed for the detection of insulin secretion in the first phase. Results. In the ezetimibe group, the fasting blood glucose was markedly reduced, and the total cholesterol (TC) and low-density lipoprotein cholesterol (LDL-C) were significantly lowered when compared with those in the control group (P < 0.05). At 120 min after glucose tolerance test, the area under curve in the ezetimibe group was significantly smaller than that in the control group (P < 0.05), but the AUCINS0−30 was markedly higher. In vitro perfusion of pancreatic islets revealed the first phase insulin secretion was improved. In addition, the insulin expression in the pancreas in the ezetimibe group was significantly increased as compared to the control group. Conclusion. Ezetimibe can improve glucose tolerance, recover the first phase insulin secretion, and protect the function of β cells in mice. PMID:23118741
The microstructural and functional changes in the macula of heavy habitual smokers.
Sobacı, Güngör; Musayev, Samir; Karslıoglu, Yıldırım; Gündoğan, Fatih Ç; Özge, Gökhan; Erdem, Üzeyir; Bayer, Atilla
2013-10-01
To investigate whether heavy habitual smoking affects microstructures and functions of the macula, 45 age- (20-39 years old) and sex-matched adult smokers (≥1 box/day for ≥5 years) and 45 nonsmokers (controls) were enrolled in this case-control study. Central macular thickness (CMT), macular autofluorescent pigment density (MAPD), macular electroretinogram (ERG), and photostress recovery time (PRT) measurements were performed. The mean age of smokers and nonsmokers was 32.9 ± 3.9 and 33.1 ± 4.1 years, respectively (p = 0.43), and smoking duration was 11 ± 5.6 years. CMT in smokers (220 ± 28 μm) and nonsmokers (217.2 ± 31 μm; p = 0.57) was similar. Smokers had lower MAPD values (124.6) than nonsmokers (138.2) (p = 0.010). Multifocal ERG parameters in the central (6°) hexagon were similar in both groups (p > 0.05 for latency and amplitudes of P1 and N1). PRT in smokers and nonsmokers was similar (7.2 ± 1.2 and 7.4 ± 1.9 min, respectively; p = 0.33); however, foveal threshold value (FTV) at the first minute after photostress was statistically higher in smokers (36.1 ± 1.04 dB) than nonsmokers (34.8 ± 1.05 dB) (p = 0.011). We conclude that decreased MAPD and altered response to photostress may be indicative of early nicotine toxicity in microstructurally sound macula of adult chronic smokers.
Mibefradil reduces blood glucose concentration in db/db mice
Lu, Yujie; Long, Min; Zhou, Shiwen; Xu, Zihui; Hu, Fuquan; Li, Ming
2014-01-01
OBJECTIVE: Numerous recent studies suggest that abnormal intracellular calcium concentration ([Ca2+]i) is a common defect in diabetic animal models and patients. Abnormal calcium handling is an important mechanism in the defective pancreatic β-cell function in type 2 diabetes. T-type Ca2+ channel antagonists lower blood glucose in type 2 diabetes, but the mechanism remains unknown. METHODS: We examined the effect of the Ca2+ channel antagonist mibefradil on blood glucose in male db/db mice and phenotypically normal heterozygous mice by intraperitoneal injection. RESULTS: Mibefradil (15 mg/kg, i.p., b.i.d.) caused a profound reduction of fasting blood glucose from 430.92±20.46 mg/dl to 285.20±5.74 mg/dl in three days. The hypoglycemic effect of mibefradil was reproduced by NNC 55-0396, a compound structurally similar to mibefradil but more selective for T-type Ca2+ channels, but not by the specific L-type Ca2+ channel blocker nicardipine. Mibefradil did not show such hypoglycemic effects in heterozygous animals. In addition, triglycerides, basal insulin and food intake were significantly decreased by mibefradil treatment in the db/db mice but not in the controls. Western blot analysis, immunohistochemistry and immunofluorescence staining showed a significantly increased expression of T-type Ca2+ channel α-subunits Cav3.1 and Cav3.2 in liver and brain tissues from db/db mice compared to those from heterozygous animals. CONCLUSIONS: Collectively, these results suggest that T-type Ca2+ channels are potential therapeutic targets for antidiabetic drugs. PMID:24473561
Lin, Gong-Ru; Pan, Ci-Ling; Chiu, I-Hsiang
2006-03-15
A backward dark-optical-comb-injection mode-locked semiconductor optical amplifier fiber laser (SOAFL) with a femtosecond pulse width and an ultrahigh supermode-noise suppressing ratio (SMSR) is primarily demonstrated. The mode-locked SOAFL pulse with a spectral linewidth of 0.45 nm is shortened from 15 to 8.6 ps under chirp compensation in a 420 m long dispersion-compensated fiber, corresponding to a time-bandwidth product of 0.48. The eighth-order soliton is obtained by the nonlinearly soliton's compression of the chirp-compensated SOAFL pulse in a 112 m long single-mode fiber at an input peak power of 51 W, providing the pulse width, the linewidth, and the nearly transform-limited time-bandwidth product are <200 fs, 13.8 nm, and 0.34, respectively. The phase noise and integrated timing jitter at an offset frequency below 1 MHz are -105 dBc/Hz and 0.8 ps, respectively. An ultrahigh pulse-compression ratio of 43 and a SMSR of 87 dB for the eighth-order SOAFL soliton are reported.