Traumatismo craneoencefálico leve
Ortega Zufiría, José Manuel; Prieto, Noemí Lomillos; Cuba, Bernardino Choque; Degenhardt, Martin Tamarit; Núñez, Pedro Poveda; López Serrano, María Remedios; López Raigada, Azahara Belén
2018-01-01
Resumen Introducción y objetivo: El TCE leve representa un problema sanitario de enorme interés debido a que un número significativo de enfermos con trauma leve desarrollará complicaciones potencialmente mortales. El objetivo de este estudio ha sido describir una serie amplia de pacientes adultos, mayores de 14 años, que sufren TCE leve, atendidos en el Hospital Universitario de Getafe, entre los años 2010 y 2015 (n = 2480), estudiar el perfil epidemiológico y analizar el diagnóstico y el tratamiento efectuados, así como establecer los principales factores pronósticos que influyen en el resultado final. Método: Se ha realizado un estudio retrospectivo, de revisión de historias clínicas, analizando los resultados con estudio estadístico bivariable y multivariable. Resultados: El TCE leve es más frecuente en varones, y el mecanismo causante más común en nuestro medio es el accidente de tráfico. Se propone un modelo de clasificación de pacientes según grupos de riesgo, que los subdivide en riesgo bajo, intermedio o alto, que se correlaciona bien con la probabilidad de desarrollar complicación intracraneal, y, consecuentemente, con el resultado final. Se discute la indicación de la radiografía simple de cráneo y de la Tomografía Computarizada (TC), así como del ingreso hospitalario para observación neurológica. Conclusiones: En este estudio, la presencia de focalidad neurológica en la exploración clínica, la edad, las alteraciones de la coagulación y la existencia de fractura en la radiografía simple se relacionan con mayor posibilidad de desarrollar lesiones traumáticas intracraneales y con peor pronóstico final. La escala de Glasgow para el Coma es deficitaria en la determinación del resultado final del paciente que sufre TCE, porque no considera variables tales como la amnesia o la pérdida de conocimiento, muy frecuentes en el traumatismo craneoencefálico leve. PMID:29430327
Application of multidetector-row computed tomography in propeller flap planning.
Ono, Shimpei; Chung, Kevin C; Hayashi, Hiromitsu; Ogawa, Rei; Takami, Yoshihiro; Hyakusoku, Hiko
2011-02-01
The propeller flap is defined as (1) being island-shaped, (2) having an axis that includes the perforators, and (3) having the ability to be rotated around an axis. The advantage of the propeller flap is that it is a pedicle flap that can be applied to cover defects located at the distal ends of the extremities. The specific aims of the authors' study were (1) to evaluate the usefulness of multidetector-row computed tomography in the planning of propeller flaps and (2) to present a clinical case series of propeller flap reconstructions that were planned preoperatively using multidetector-row computed tomography. The authors retrospectively analyzed all cases between April of 2007 and April of 2010 at Nippon Medical School Hospital in Tokyo, where multidetector-row computed tomography was used preoperatively to plan surgical reconstructions using propeller flaps. Thirteen patients underwent 16 flaps using the propeller flap technique. The perforators were identified accurately by multidetector-row computed tomography preoperatively in all cases. This is the first report describing the application of multidetector-row computed tomography in the planning of propeller flaps. Multidetector-row computed tomography is superior to other imaging methods because it demonstrates more precisely the perforator's position and subcutaneous course using high-resolution three-dimensional images. By using multidetector-row computed tomography to preoperatively identify a flap's perforators, the surgeon can better plan the flap design to efficiently conduct the flap surgery.
Maier, I L; Leyhe, J R; Tsogkas, I; Behme, D; Schregel, K; Knauth, M; Schnieder, M; Liman, J; Psychogios, M-N
2018-05-01
One-stop management of mechanical thrombectomy-eligible patients with large-vessel occlusion represents an innovative approach in acute stroke treatment. This approach reduces door-to-reperfusion times by omitting multidetector CT, using flat detector CT as pre-mechanical thrombectomy imaging. The purpose of this study was to compare the diagnostic performance of the latest-generation flat detector CT with multidetector CT. Prospectively derived data from patients with ischemic stroke with large-vessel occlusion and mechanical thrombectomy were analyzed in this monocentric study. All included patients underwent multidetector CT before referral to our comprehensive stroke center and flat detector CT in the angiography suite before mechanical thrombectomy. Diagnosis of early ischemic signs, quantified by the ASPECTS, was compared between modalities using cross tables, the Pearson correlation, and Bland-Altman plots. The predictive value of multidetector CT- and flat detector CT-derived ASPECTS for functional outcome was investigated using area under the receiver operating characteristic curve analysis. Of 25 patients, 24 (96%) had flat detector CT with sufficient diagnostic quality. Median multidetector CT and flat detector CT ASPECTSs were 7 (interquartile range, 5.5-9 and 4.25-8, respectively) with a mean period of 143.6 ± 49.5 minutes between both modalities. The overall sensitivity was 85.1% and specificity was 83.1% for flat detector CT ASPECTS compared with multidetector CT ASPECTS as the reference technique. Multidetector CT and flat detector CT ASPECTS were strongly correlated ( r = 0.849, P < .001) and moderately predicted functional outcome (area under the receiver operating characteristic curve, 0.738; P = .007 and .715; P = .069, respectively). Determination of ASPECTS on flat detector CT is feasible, showing no significant difference compared with multidetector CT ASPECTS and a similar predictive value for functional outcome. Our findings support the use of flat detector CT for emergency stroke imaging before mechanical thrombectomy to reduce door-to-groin time. © 2018 by American Journal of Neuroradiology.
Martina, Maria Cristina; Cesarani, Federico; Boano, Rosa; Fiore Marochetti, Elisa; Gandini, Giovanni
The objective of our work was to report the most recent findings obtained with multidetector computed tomography of a child mummy from the Roman period (119-123 CE) housed at the Egyptian Museum in Turin, Italy. Multidetector computed tomography and postprocessing were applied to understand the embalming techniques, the nature of a foreign object, and anthropometrical values. The information was compared with that from other mummies that were buried in the same tomb, but today housed in different museums. New information regarding the embalming technique was revealed. Multidetector computed tomography allowed the identification of a knife-like metallic object, probably an amulet for the child's protection in the afterlife. Multidetector computed tomography and image postprocessing confirm their valuable role in noninvasive studies in ancient mummies and provided evidence of a unique cultural practice in the late history of Ancient Egypt such as placing a knife possibly as an amulet.
Bolliger, Stephan A; Ross, Steffen; Thali, Michael J; Hostettler, Bernhard; Menkveld-Gfeller, Ursula
2012-01-01
The study of fossils permits the reconstruction of past life on our planet and enhances our understanding of evolutionary processes. However, many fossils are difficult to recognize, being encased in a lithified matrix whose tedious removal is required before examination is possible. The authors describe the use of multidetector computed tomography (CT) in locating, identifying, and examining fossil remains of crocodilians (Mesosuchia) embedded in hard shale, all without removing the matrix. In addition, they describe how three-dimensional (3D) reformatted CT images provided details that were helpful for extraction and preparation. Multidetector CT can help experienced paleontologists localize and characterize fossils in the matrix of a promising rock specimen in a nondestructive manner. Moreover, with its capacity to generate highly accurate 3D images, multidetector CT can help determine whether the fossils warrant extraction and can assist in planning the extraction process. Thus, multidetector CT may well become an invaluable tool in the field of paleoradiology.
Soukup, Jason W; Drees, Randi; Koenig, Lisa J; Snyder, Christopher J; Hetzel, Scott; Miles, Chanda R; Schwarz, Tobias
2015-01-01
The objective of this blinded study was to validate the use of cone beam computed tomography (C) for imaging of the canine maxillary dentoalveolar structures by comparing its diagnostic image quality with that of 64-multidetector row CT Sagittal slices of a tooth-bearing segment of the maxilla of a commercially purchased dog skull embedded in methylmethacrylate were obtained along a line parallel with the dental arch using a commercial histology diamond saw. The slice of tooth-bearing bone that best depicted the dentoalveolar structures was chosen and photographed. The maxillary segment was imaged with cone beam CT and 64-multidetector row CT. Four blinded evaluators compared the cone beam CT and 64-multidetector row CT images and image quality was scored as it related to the anatomy of dentoalveolar structures. Trabecular bone, enamel, dentin, pulp cavity, periodontal ligament space, and lamina dura were scored In addition, a score depicting the evaluators overall impression of the image was recorded. Images acquired with cone beam CT were found to be significantly superior in image quality to images acquired with 64-multidetector row CT overall, and in all scored categories. In our study setting cone beam CT was found to be a valid and clinically superior imaging modality for the canine maxillary dentoalveolar structures when compared to 64-multidetector row CT.
Soukup, Jason W.; Drees, Randi; Koenig, Lisa J.; Snyder, Christopher J.; Hetzel, Scott; Miles, Chanda R.; Schwarz, Tobias
2016-01-01
Summary The objective of this blinded study was to validate the use of cone beam computed tomography (CT) for imaging of the canine maxillary dentoalveolar structures by comparing its diagnostic image quality with that of 64-multidetector row CT. Sagittal slices of a tooth-bearing segment of the maxilla of a commercially purchased dog skull embedded in methyl methacrylate were obtained along a line parallel with the dental arch using a commercial histology diamond saw. The slice of tooth-bearing bone that best depicted the dentoalveolar structures was chosen and photographed. The maxilla segment was imaged with cone beam CT and 64-multidetector row CT. Four blinded evaluators compared the cone beam CT and 64-multidetector row CT images and image quality was scored as it related to the anatomy of dentoalveolar structures. Trabecular bone, enamel, dentin, pulp cavity, periodontal ligament space, and lamina dura were scored. In addition, a score depicting the evaluators overall impression of the image was recorded. Images acquired with cone beam CT were found to be significantly superior in image quality to images acquired with 64-multidetector row CT overall, and in all scored categories. In our study setting, cone beam CT was found to be a valid and clinically superior imaging modality for the canine maxillary dentoalveolar structures when compared to 64-multidetector row CT. PMID:26415384
Multidetector Computed Tomography for Congenital Anomalies of the Aortic Arch: Vascular Rings.
García-Guereta, Luis; García-Cerro, Estefanía; Bret-Zurita, Montserrat
2016-07-01
The development of multidetector computed tomography has triggered a revolution in the study of the aorta and other large vessels and has replaced angiography in the diagnosis of congenital anomalies of the aortic arch, particularly vascular rings. The major advantage of multidetector computed tomography is that it permits clear 3-dimensional assessment of not only vascular structures, but also airway and esophageal compression. The current update aims to summarize the embryonic development of the aortic arch and the developmental anomalies leading to vascular ring formation and to discuss the current diagnostic and therapeutic role of multidetector computed tomography in this field. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Kumar, Sheo; Neyaz, Zafar; Gupta, Archna
2010-01-01
The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment.
Kim, Bo Ram; Lee, Jeong Min; Lee, Dong Ho; Yoon, Jeong Hee; Hur, Bo Yun; Suh, Kyung Suk; Yi, Nam-Joon; Lee, Kyung Boon; Han, Joon Koo
2017-10-01
Purpose To compare the diagnostic performance of gadoxetic acid-enhanced liver magnetic resonance (MR) imaging with that of contrast material-enhanced multidetector computed tomography (CT) in the detection of borderline hepatocellular nodules in patients with liver cirrhosis and to determine the Liver Imaging Reporting and Data System (LI-RADS) categories of these detected nodules. Materials and Methods The institutional review board approved this retrospective study and waived the informed consent requirement. Sixty-eight patients with pathologically proven dysplastic nodules (DNs) (low-grade DNs, n = 20; high-grade DNs, n = 17), early hepatocellular carcinomas (HCCs) (n = 42), or progressed HCCs (n = 33) underwent gadoxetic acid-enhanced MR imaging and multidetector CT. An additional 57 patients without any DNs or HCCs in the explanted livers were included as control subjects. Three radiologists independently graded the presence of liver nodules on a five-point confidence scale and assigned LI-RADS categories by using imaging findings. Jackknife alternative free-response receiver operating characteristics (JAFROC) software was used to compare the diagnostic accuracy of each modality in lesion detection. Results Reader-averaged figures of merit estimated with JAFROC software to detect hepatocellular nodules were 0.774 for multidetector CT and 0.842 for MR imaging (P = .002). Readers had significantly higher detection sensitivity for early HCCs with MR imaging than with multidetector CT (78.6% vs 52.4% [P = .001], 71.4% vs 50.0% [P = .011], and 73.8% vs 50.0% [P = .001], respectively). A high proportion of overall detected early HCCs at multidetector CT (59.4%) and MR imaging (72.3%) were categorized as LI-RADS category 4. Most early HCCs (76.2%) and high-grade DNs (82.4%) demonstrated hypointensity on hepatobiliary phase images. In total, 30 more LI-RADS category 4 early HCCs were identified with MR imaging than with multidetector CT across all readers. Conclusion Gadoxetic acid-enhanced MR imaging performed significantly better in the detection of high-risk borderline nodules, especially early HCCs, than did multidetector CT. © RSNA, 2017 Online supplemental material is available for this article.
Diagnosis and classification of pancreatic and duodenal injuries in emergency radiology.
Linsenmaier, Ulrich; Wirth, Stefan; Reiser, Maximilian; Körner, Markus
2008-10-01
Pancreatic and duodenal injuries after blunt abdominal trauma are rare; however, delays in diagnosis and treatment can significantly increase morbidity and mortality. Multidetector computed tomography (CT) has a major role in early diagnosis of pancreatic and duodenal injuries. Detecting the often subtle signs of injury with whole-body CT can be difficult because this technique usually does not include a dedicated protocol for scanning the pancreas. Specific injury patterns in the pancreas and duodenum often have variable expression at early posttraumatic multidetector CT: They may be hardly visible, or there may be considerable exudate, hematomas, organ ruptures, or active bleeding. An accurate multidetector CT technique allows optimized detection of subtle abnormalities. In duodenal injuries, differentiation between a contusion of the duodenal wall or mural hematoma and a duodenal perforation is vital. In pancreatic injuries, determination of involvement of the pancreatic duct is essential. The latter conditions require immediate surgical intervention. Use of organ injury scales and a surgical classification adapted for multidetector CT enables classification of organ injuries for trauma scoring, treatment planning, and outcome control. In addition, multidetector CT reliably demonstrates potential complications of duodenal and pancreatic injuries, such as posttraumatic pancreatitis, pseudocysts, fistulas, exudates, and abscesses. (c) RSNA, 2008.
Monte: A compact and versatile multidetector system based on monolithic telescopes
NASA Astrophysics Data System (ADS)
Amorini, F.; Bonanno, A.; Cardella, G.; di Pietro, A.; Fallica, G.; Figuera, P.; Morea, A.; Musumarra, A.; Papa, M.; Pappalardo, G.; Pinto, A.; Rizzo, F.; Tian, W.; Tudisco, S.; Valvo, G.
2005-09-01
We present the characteristics of a new multidetector based on monolithic silicon telescopes: MONTE. By using high-energy ion implantation techniques, the ΔE and residual energy stages of such telescopes have been integrated on the same silicon chip, obtaining extremely thin ΔE stages of the order of 1 μm. This allowed one to obtain a very low charge identification energy threshold and a very good β background suppression in reactions induced by radioactive ion beams. The multidetector has a modular structure and can be assembled in different geometrical configurations according to experimental needs.
Multi-detector row computed tomography angiography of peripheral arterial disease
Dijkshoorn, Marcel L.; Pattynama, Peter M. T.; Myriam Hunink, M. G.
2007-01-01
With the introduction of multi-detector row computed tomography (MDCT), scan speed and image quality has improved considerably. Since the longitudinal coverage is no longer a limitation, multi-detector row computed tomography angiography (MDCTA) is increasingly used to depict the peripheral arterial runoff. Hence, it is important to know the advantages and limitations of this new non-invasive alternative for the reference test, digital subtraction angiography. Optimization of the acquisition parameters and the contrast delivery is important to achieve a reliable enhancement of the entire arterial runoff in patients with peripheral arterial disease (PAD) using fast CT scanners. The purpose of this review is to discuss the different scanning and injection protocols using 4-, 16-, and 64-detector row CT scanners, to propose effective methods to evaluate and to present large data sets, to discuss its clinical value and major limitations, and to review the literature on the validity, reliability, and cost-effectiveness of multi-detector row CT in the evaluation of PAD. PMID:17882427
Brewer, Amandaa K; Striegel, André M
2011-04-15
The string-of-pearls-type morphology is ubiquitous, manifesting itself variously in proteins, vesicles, bacteria, synthetic polymers, and biopolymers. Characterizing the size and shape of analytes with such morphology, however, presents a challenge, due chiefly to the ease with which the "strings" can be broken during chromatographic analysis or to the paucity of information obtained from the benchmark microscopy and off-line light scattering methods. Here, we address this challenge with multidetector hydrodynamic chromatography (HDC), which has the ability to determine, simultaneously, the size, shape, and compactness and their distributions of string-of-pearls samples. We present the quadruple-detector HDC analysis of colloidal string-of-pearls silica, employing static multiangle and quasielastic light scattering, differential viscometry, and differential refractometry as detection methods. The multidetector approach shows a sample that is broadly polydisperse in both molar mass and size, with strings ranging from two to five particles, but which also contains a high concentration of single, unattached "pearls". Synergistic combination of the various size parameters obtained from the multiplicity of detectors employed shows that the strings with higher degrees of polymerization have a shape similar to the theory-predicted shape of a Gaussian random coil chain of nonoverlapping beads, while the strings with lower degrees of polymerization have a prolate ellipsoidal shape. The HDC technique is contrasted experimentally with multidetector size-exclusion chromatography, where, even under extremely gentle conditions, the strings still degraded during analysis. Such degradation is shown to be absent in HDC, as evidenced by the fact that the molar mass and radius of gyration obtained by HDC with multiangle static light scattering detection (HDC/MALS) compare quite favorably to those determined by off-line MALS analysis under otherwise identical conditions. The multidetector HDC results were also comparable to those obtained by transmission electron microscopy (TEM). Unlike off-line MALS or TEM, however, multidetector HDC is able to provide complete particle analysis based on the molar mass, size, shape, and compactness and their distributions for the entire sample population in less than 20 min. © 2011 American Chemical Society
Multidetector Scattering as a Probe of Local Structure in Disordered Phases
NASA Astrophysics Data System (ADS)
Clark, Noel A.; Ackerson, Bruce J.; Hurd, Alan J.
1983-05-01
The local translational structure of a two-dimensional colloidal liquid is observed by use of cross correlation of the intensity fluctuations of light scattered by the liquid through two different wave vectors. The utility of multidetector scattering in probing multipoint correlations in disordered phases is thereby demonstrated unambiguously.
Multidetector CT of blunt traumatic venous injuries in the chest, abdomen, and pelvis.
Holly, Brian P; Steenburg, Scott D
2011-01-01
Venous injuries as a result of blunt trauma are rare. Even though current protocols for multidetector computed tomography (CT) of patients with trauma are designed to evaluate primarily the solid organs and arteries, blunt venous injuries may nevertheless be identified, or at least suspected, on the basis of the multidetector CT findings. Venous injuries are associated with high morbidity and mortality rates. Diagnosis of a possible venous injury is crucial because the physical findings of a venous injury are nonspecific and may be absent. This article aims to make the radiologist aware of various venous injuries caused by blunt trauma and to provide helpful hints to aid in the identification of venous injuries. Multidetector CT technology, in combination with interactive manipulation of the raw dataset, can be useful in the creation of multiplanar reconstructed images and in the identification of a venous injury caused by blunt trauma. Familiarity with direct and indirect signs of venous injuries, as well as with examples of blunt traumatic venous injuries in the chest, abdomen, and pelvis, will help in the diagnosis of these injuries.
T staging of gastric cancer: role of multi-detector row CT.
Kumano, Seishi; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Iannaccone, Riccardo; Nakata, Saki; Onishi, Hiromitsu; Osuga, Keigo; Tomoda, Kaname; Catalano, Carlo; Nakamura, Hironobu
2005-12-01
To evaluate retrospectively the accuracy of multi-detector row computed tomography (CT) in the assessment of serosal invasion in patients with gastric cancer. The Ethics Committee does not require approval or informed consent for retrospective studies. Forty-one consecutive patients (24 men, 17 women; mean age, 68 years) with gastric cancer were included in this study. All patients were given 600 mL of tap water to drink and were positioned prone or supine on the scanning table. The detector row configuration included four detector rows, a section thickness of 1.25 mm, a pitch of 6, and a reconstruction interval of 0.63 mm. Transverse and multiplanar reconstruction images were simultaneously evaluated by two independent observers to assess the depth of tumor invasion in the gastric wall (ie, T stage). T staging at multi-detector row CT was compared with T staging at histologic evaluation (reference standard), which was performed by means of surgical or histologic examination of the resected specimen. We also calculated the sensitivity, specificity, and accuracy of multi-detector row CT for each observer in the assessment of serosal invasion. Analysis of interobserver agreement showed substantial or almost perfect agreement (nonweighted kappa value of 0.78 and weighted kappa value of 0.85). Correct assessment of gastric wall invasion was 80% and 85% for observers 1 and 2, respectively. The sensitivity, specificity, and accuracy of multi-detector row CT in the assessment of serosal invasion were 90%, 95%, and 93%, respectively, for observer 1 and 80%, 97%, and 93%, respectively, for observer 2. Overstaging occurred in six patients, and understaging occurred in five patients. All understaged tumors were scirrhous subtype gastric cancer. Multi-detector row CT scanning of patients with gastric cancer gave 93% accuracy in the assessment of serosal invasion in patients with gastric cancer. RSNA, 2005
De Maeseneer, M; Buls, N; Cleeren, N; Lenchik, L; De Mey, J
2006-01-01
We present an unusual application of multidetector CT and shaded surface rendering in the investigation of a soil sample, containing an ancient Roman bronze bowl. The CT findings were of fundamental importance in helping the archaeologists study the bronze bowl from the soil sample.
Patent foramen ovale: detection with nongated multidetector CT.
Revel, Marie-Pierre; Faivre, Jean-Baptiste; Letourneau, Thierry; Henon, Hilde; Leys, Didier; Delannoy-Deken, Valérie; Remy-Jardin, Martine; Remy, Jacques
2008-10-01
To evaluate nongated multidetector computed tomography (CT) in the detection of patent foramen ovale (PFO) and atrial septal aneurysm (ASA) in comparison with transesophageal echocardiography (TEE). The study was approved by the institutional review board, and informed consent was obtained from all patients. One hundred five patients (57 men, 48 women; mean age, 53 years) with a recent stroke underwent TEE and multidetector CT on the same day. After injection of a diluted iodinated contrast material, a series of 2.4-mm-thick transverse images centered on the fossa ovalis were acquired in conjunction with release of the Valsalva maneuver. Two independent radiologists considered PFO present if left atrial enhancement was detected visually before enhancement of the pulmonary veins or if an early peak of left atrial enhancement was found at time-attenuation curve analysis. PFO was detected with 98% specificity (95% confidence interval [CI]: 0.91, 0.99). Overall sensitivity was 55% (95% CI: 0.38, 0.70), ranging from 28% for shunts classified as grade 1 at TEE to 91% for those classified as grade 4 at TEE. Interreader agreement was good (kappa = 0.81). Visual assessment was better than time-attenuation curve analysis, which enabled detection of only 15 of the 40 cases of PFO. Multidetector CT depicted only 22% of cases of ASA. The mean effective radiation dose was 2.3 mSv. Nongated multidetector CT can be used to diagnose high-grade shunts through a PFO, with 91% sensitivity and 98% specificity. Thus, PFO detection, in addition to routine CT evaluation of the lungs, could be indicated in patients with unexplained hypoxemia. (c) RSNA, 2008.
Yun, Chun-Ho; Schlett, Christopher L; Rogers, Ian S; Truong, Quynh A; Toepker, Michael; Donnelly, Patrick; Brady, Thomas J; Hoffmann, Udo; Bamberg, Fabian
2009-08-01
The aim of the study was to assess differences in the presence, extent, and composition of coronary atherosclerotic plaque burden as detected by coronary multidetector computed tomography (MDCT) between patients with and without diabetes mellitus. We compared coronary atherosclerotic plaques (any plaque, calcified [CAP], non-calcified [NCAP, and mixed plaque [MCAP
Relationship between noise, dose, and pitch in cardiac multi-detector row CT.
Primak, Andrew N; McCollough, Cynthia H; Bruesewitz, Michael R; Zhang, Jie; Fletcher, Joel G
2006-01-01
In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends on pitch because the spiral interpolation algorithm makes use of redundant data from different detector rows to decrease noise for pitch values less than 1 (and increase noise for pitch values > 1). However, in cardiac spiral CT, redundant data cannot be used because such data averaging would degrade the temporal resolution. Therefore, the behavior of noise versus pitch returns to the single detector row paradigm, with noise being independent of pitch. Consequently, since faster rotation times require lower pitch values in cardiac multi-detector row CT, dose is increased without a commensurate decrease in noise. Thus, the use of faster rotation times will improve temporal resolution, not alter noise, and increase dose. For a particular application, the higher dose resulting from faster rotation speeds should be justified by the clinical benefits of the improved temporal resolution. RSNA, 2006
Methods for radiation detection and characterization using a multiple detector probe
Akers, Douglas William; Roybal, Lyle Gene
2014-11-04
Apparatuses, methods, and systems relating to radiological characterization of environments are disclosed. Multi-detector probes with a plurality of detectors in a common housing may be used to substantially concurrently detect a plurality of different radiation activities and types. Multiple multi-detector probes may be used in a down-hole environment to substantially concurrently detect radioactive activity and contents of a buried waste container. Software may process, analyze, and integrate the data from the different multi-detector probes and the different detector types therein to provide source location and integrated analysis as to the source types and activity in the measured environment. Further, the integrated data may be used to compensate for differential density effects and the effects of radiation shielding materials within the volume being measured.
Moores, L; Kline, J; Portillo, A K; Resano, S; Vicente, A; Arrieta, P; Corres, J; Tapson, V; Yusen, R D; Jiménez, D
2016-01-01
ESSENTIALS: When high probability of pulmonary embolism (PE), sensitivity of computed tomography (CT) is unclear. We investigated the sensitivity of multidetector CT among 134 patients with a high probability of PE. A normal CT alone may not safely exclude PE in patients with a high clinical pretest probability. In patients with no clear alternative diagnosis after CTPA, further testing should be strongly considered. Whether patients with a negative multidetector computed tomographic pulmonary angiography (CTPA) result and a high clinical pretest probability of pulmonary embolism (PE) should be further investigated is controversial. This was a prospective investigation of the sensitivity of multidetector CTPA among patients with a priori clinical assessment of a high probability of PE according to the Wells criteria. Among patients with a negative CTPA result, the diagnosis of PE required at least one of the following conditions: ventilation/perfusion lung scan showing a high probability of PE in a patient with no history of PE, abnormal findings on venous ultrasonography in a patient without previous deep vein thrombosis at that site, or the occurrence of venous thromboembolism (VTE) in a 3-month follow-up period after anticoagulation was withheld because of a negative multidetector CTPA result. We identified 498 patients with a priori clinical assessment of a high probability of PE and a completed CTPA study. CTPA excluded PE in 134 patients; in these patients, the pooled incidence of VTE was 5.2% (seven of 134 patients; 95% confidence interval [CI] 1.5-9.0). Five patients had VTEs that were confirmed by an additional imaging test despite a negative CTPA result (five of 48 patients; 10.4%; 95% CI 1.8-19.1), and two patients had objectively confirmed VTEs that occurred during clinical follow-up of at least 3 months (two of 86 patients; 2.3%; 95% CI 0-5.5). None of the patients had a fatal PE during follow-up. A normal multidetector CTPA result alone may not safely exclude PE in patients with a high clinical pretest probability. © 2015 International Society on Thrombosis and Haemostasis.
Role of virtual bronchoscopy in children with a vegetable foreign body in the tracheobronchial tree.
Behera, G; Tripathy, N; Maru, Y K; Mundra, R K; Gupta, Y; Lodha, M
2014-12-01
Multidetector computed tomography virtual bronchoscopy is a non-invasive diagnostic tool which provides a three-dimensional view of the tracheobronchial airway. This study aimed to evaluate the usefulness of virtual bronchoscopy in cases of vegetable foreign body aspiration in children. The medical records of patients with a history of foreign body aspiration from August 2006 to August 2010 were reviewed. Data were collected regarding their clinical presentation and chest X-ray, virtual bronchoscopy and rigid bronchoscopy findings. Cases of metallic and other non-vegetable foreign bodies were excluded from the analysis. Patients with multidetector computed tomography virtual bronchoscopy showing features of vegetable foreign body were included in the analysis. For each patient, virtual bronchoscopy findings were reviewed and compared with those of rigid bronchoscopy. A total of 60 patients; all children ranging from 1 month to 8 years of age, were included. The mean age at presentation was 2.01 years. Rigid bronchoscopy confirmed the results of multidetector computed tomography virtual bronchoscopy (i.e. presence of foreign body, site of lodgement, and size and shape) in 59 patients. In the remaining case, a vegetable foreign body identified by virtual bronchoscopy was revealed by rigid bronchoscopy to be a thick mucus plug. Thus, the positive predictive value of virtual bronchoscopy was 98.3 per cent. Multidetector computed tomography virtual bronchoscopy is a sensitive and specific diagnostic tool for identifying radiolucent vegetable foreign bodies in the tracheobronchial tree. It can also provide a useful pre-operative road map for rigid bronchoscopy. Patients suspected of having an airway foreign body or chronic unexplained respiratory symptoms should undergo multidetector computed tomography virtual bronchoscopy to rule out a vegetable foreign body in the tracheobronchial tree and avoid general anaesthesia and invasive rigid bronchoscopy.
Caro-Domínguez, Pablo; Compton, Gregory; Humpl, Tilman; Manson, David E
2016-09-01
The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children.
Ectopic Multinodular Goiter: Multidetector Computed Tomography Findings
Karakaya, Afak Durur; Kantarci, Mecit; Yalcin, Ahmet; Demir, Berrin
2008-01-01
The thyroid is the first endocrine gland to form during embryogenesis. At this stage, incomplete or anomalous migration of thyroid tissue causes ectopic localization of the gland. In our case, a 55-year-old woman who was evaluated via ultrasonography (USG) and multi-detector computed tomography (MDCT) had no thyroid gland at the normal location, but did have ectopic thyroid tissue in the left submandibular and submental regions. PMID:25610021
[Sigmoid endometriosis: a diagnostic dilemma on multidetector CT].
Telegrafo, Michele; Lorusso, Valentina; Rubini, Giuseppe; Rella, Leonarda; Pezzolla, Angela; Stabile Ianora, Amato Antonio; Moschetta, Marco
2013-01-01
Intestinal endometriosis represents a common condition that occurs particularly in women of reproductive age. The gastrointestinal tract is the third most common localization of endometriosis, after the ovaries and the peritoneum, and recto-sigmoid tract is involved in 70% of cases. Recto-sigmoid endometriosis has to be differentiated from other diseases of large bowel, especially in patients without a history of endometriosis. We report a case of sigmoid endometriosis which represented a diagnostic dilemma on multidetector computed tomography.
Wyler, Annabelle; Bousson, Valérie; Bergot, Catherine; Polivka, Marc; Leveque, Eric; Vicaut, Eric; Laredo, Jean-Denis
2007-02-01
To assess spiral multidetector computed tomographic (CT) arthrography for the depiction of cartilage thickness in hips without cartilage loss, with evaluation of anatomic slices as the reference standard. Permission to perform imaging studies in cadaveric specimens of individuals who had willed their bodies to science was obtained from the institutional review board. Two independent observers measured the femoral and acetabular hyaline cartilage thickness of 12 radiographically normal cadaveric hips (from six women and five men; age range at death, 52-98 years; mean, 76.5 years) on spiral multidetector CT arthrographic reformations and on coronal anatomic slices. Regions of cartilage loss at gross or histologic examination were excluded. CT arthrographic and anatomic measurements in the coronal plane were compared by using Bland-Altman representation and a paired t test. Differences between mean cartilage thicknesses at the points of measurement were tested by means of analysis of variance. Interobserver and intraobserver reproducibilities were determined. At CT arthrography, mean cartilage thickness ranged from 0.32 to 2.53 mm on the femoral head and from 0.95 to 3.13 mm on the acetabulum. Observers underestimated cartilage thickness in the coronal plane by 0.30 mm +/- 0.52 (mean +/- standard error) at CT arthrography (P < .001) compared with the anatomic reference standard. Ninety-five percent of the differences between CT arthrography and anatomic values ranged from -1.34 to 0.74 mm. The difference between mean cartilage thicknesses at the different measurement points was significant for coronal spiral multidetector CT arthrography and anatomic measurement of the femoral head and acetabulum and for sagittal and transverse CT arthrography of the femoral head (P < .001). Changes in cartilage thickness from the periphery to the center of the joint ("gradients") were found by means of spiral multidetector CT arthrography and anatomic measurement. Spiral multidetector CT arthrography depicts cartilage thickness gradients in radiographically normal cadaveric hips. (c) RSNA, 2007.
López-Ramírez, M A; Lever-Rosas, C D; Motta-Ramírez, G A; Rebollo-Hurtado, V; Guzmán-Bárcenas, J; Fonseca-Morales, J V; Carreño-Lomeli, M A
In relation to the number of new cases diagnosed, gastric cancer is the fourth most common cancer worldwide, and the second cause of cancer death. The development of multidetector tomography has improved the preoperative staging of gastric cancer. To correlate preoperative tomographic studies with the definitive pathologic results according to the TNM staging system. A retrospective, cross-sectional study within the time frame of January 2009 to December 2013 was conducted that included the case records of 67 patients. They all had upper endoscopy and preoperative multidetector tomography examinations, underwent surgical resection, and had the corresponding histopathology study. Statistical analysis was carried out with the SPSS version 15.0 software and the sensitivity and specificity calculations were made using the Excel 2011 program for Mac. The majority of the patients included in the case series had clinical stage iii and iv disease. When compared with the histopathologic result, the overall accuracy of multidetector CT was 83% (T0 96%, T1 94%, T2 93%, T3 67%, and T4 67%) for tumor size (T) and was 70% (N0 72%, N1 73%, N2 70%, and N3 66%) for lymph node involvement (N). Overall sensitivity was 48% (T0 100%, T1 0%, T2 33%, T3 44%, and T4 65%) for T and was 41% (N0 58%, N1 56%, N2 15%, and N3 35%) for N. A strong association between the multidetector CT results and the pathology results was demonstrated through the Spearman's correlation, especially in T4 and N3. Multidetector computed tomography showed greater congruency in detecting stages T4, N0, and N3 in gastric cancer, when compared with the definitive histopathologic results. Copyright © 2017 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.
NASA Technical Reports Server (NTRS)
Knaub, D.; Yerazunis, S. W.
1978-01-01
Vertical wheel loads, wheel speeds, and torque relationships are considered in the design of a propulsion system capable of responding to steering, slope climbing, and irregular local terrains. The system developed is applied to the RPI Mars roving vehicle. The mechanical system required to implement the elevation laser scanning/multidetector principle was the design and construction of a mechanical system for implementing the elevation scanning/multidetector principle is also discussed.
Wanner, Matthew R; Karmazyn, Boaz; Fan, Rong
2015-12-01
Hemobilia secondary to gallbladder polyposis is rare in children but has been reported in a few children with metachromatic leukodystrophy. We present a case with preoperative multidetector computed tomography (MDCT) diagnosis of massive hemobilia caused by gallbladder polyposis in a patient with metachromatic leukodystrophy. Our report highlights the importance of both awareness of the association of gallbladder polyposis with other syndromes such as metachromatic leukodystrophy as well as the possibility of this entity presenting with life-threatening bleeding.
Fayad, Laura M; Johnson, Pamela; Fishman, Elliot K
2005-01-01
Computed tomography (CT) plays an important role in the evaluation of musculoskeletal disease in the pediatric patient. With the advent of high-performance 16-section multidetector CT, images can be produced with subsecond gantry rotation times and with submillimeter acquisition, which yields true isotropic high-resolution volume data sets; these features are not attainable with older spiral CT technology. Such capabilities are particularly helpful in the evaluation of pediatric patients by virtually eliminating the need for sedation and minimizing dependence on patient cooperation. The role of three-dimensional (3D) volume imaging in the evaluation of pediatric musculoskeletal disease continues to evolve, with this technique becoming increasingly important in detection and characterization of lesions as well as in decisions about patient care. Specific designs and protocols for multidetector CT studies can be selected to minimize radiation dose to the patient. Principal clinical applications of 3D CT in evaluation of the pediatric musculoskeletal system include developmental abnormalities, trauma, neoplasms, and postoperative imaging.
Sivanandam, S E; Mathew, Georgie; Bhat, Sanjay H
2009-07-01
Persistent hematuria is one of the most dreaded complications following percutanous nephrolithotomy (PCNL). Although invasive, a catheter-based angiogram is usually used to localize the bleeding vessel and subsequently embolize it. Advances in imaging technology have now made it possible to use a non invasive multi-detector computed tomography (MDCT) angiogram with 3-D reconstruction to establish the diagnosis. We report a case of post-PCNL hemorrhage due to a pseudo aneurysm that was missed by a conventional angiogram and subsequently detected on MDCT angiogram.
Raman, Siva P; Lessne, Mark; Kawamoto, Satomi; Chen, Yifei; Salvatori, Roberto; Prescott, Jason D; Fishman, Elliot K
2015-01-01
The management of patients with primary hyperaldosteronism (PH) varies depending on whether the unregulated aldosterone secretion localizes to a single unilateral adrenal gland, traditionally determined using adrenal vein sampling (AVS). This study seeks to determine if the performance of multidetector computed tomography (MDCT) examinations performed using the latest scanner technology can reasonably match the results of AVS, and potentially avoid AVS in some patients. Computed tomographic scans in 56 patients with PH were independently reviewed by 2 radiologists for the presence of adrenal nodules and qualitative adrenal thickening. Results were correlated with AVS results. Of 35 patients with MDCT evidence of unilateral nodules, the imaging findings correctly predicted AVS localization in only 23 (65.7%) cases. When stratified by size, MDCT was accurate in only 71.4% of cases for nodules measuring 10 mm or less, and only 55.0% of cases for nodules measuring 11 to 20 mm. Of the 12 cases where MDCT did not correctly localize, AVS localized to the contralateral adrenal gland in 4 cases, whereas AVS suggested no lateralization in 8 cases. In patients with normal bilateral adrenal glands on MDCT, 2/7 (28.6%) of cases demonstrated unilateral localization on AVS, and in patients with bilateral adrenal nodules, only 3/14 (21.4%) did not demonstrate lateralization on AVS. Multidetector computed tomography, even when performed with the latest generation of MDCT scanners, does not offer sufficient diagnostic accuracy to replace AVS in patients with PH.
Novel wearable and wireless ring-type pulse oximeter with multi-detectors.
Huang, Cheng-Yang; Chan, Ming-Che; Chen, Chien-Yue; Lin, Bor-Shyh
2014-09-19
The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2). Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the above issue. However, the tissue structure of the finger base is complex, and there is lack of detailed information on the effect of the light source and detector placement on measuring SPO2. In this study, the practicability of a ring-type pulse oximeter with a multi-detector was investigated by optical human tissue simulation. The optimal design of a ring-type pulse oximeter that can provide the best efficiency of measuring SPO2 was discussed. The efficiency of ring-type pulse oximeters with a single detector and a multi-detector was also discussed. Finally, a wearable and wireless ring-type pulse oximeter was also implemented to validate the simulation results and was compared with the commercial fingertip-type pulse oximeter.
Novel Wearable and Wireless Ring-Type Pulse Oximeter with Multi-Detectors
Huang, Cheng-Yang; Chan, Ming-Che; Chen, Chien-Yue; Lin, Bor-Shyh
2014-01-01
The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2). Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the above issue. However, the tissue structure of the finger base is complex, and there is lack of detailed information on the effect of the light source and detector placement on measuring SPO2. In this study, the practicability of a ring-type pulse oximeter with a multi-detector was investigated by optical human tissue simulation. The optimal design of a ring-type pulse oximeter that can provide the best efficiency of measuring SPO2 was discussed. The efficiency of ring-type pulse oximeters with a single detector and a multi-detector was also discussed. Finally, a wearable and wireless ring-type pulse oximeter was also implemented to validate the simulation results and was compared with the commercial fingertip-type pulse oximeter. PMID:25244586
[The role of multidetector computer tomography in diagnosis of acute pancreatitis].
Lohanikhina, K Iu; Hordiienko, K P; Kozarenko, T M
2014-10-01
With the objective to improve the diagnostic semiotics of an acute pancreatitis (AP) 35 patients were examined, using 64-cut computeric tomograph Lightspeed VCT (GE, USA) with intravenous augmentation in arterial and portal phases. Basing on analysis of the investigations conducted, using multidetector computeric tomography (MDCT), the AP semiotics was systematized, which is characteristic for oedematous and destructive forms, diagnosed in 19 (44.2%) and 16 (45.8%) patients, accordingly. The procedure for estimation of preservation of the organ functional capacity in pancreonecrosis pres- ence was elaborated, promoting rising of the method diagnostic efficacy by 5.3 - 9.4%.
Multidetector computed tomography diagnosis of gastric volvulus through the foramen of Morgagni.
Lecouvet, S; Coulier, B; Pierard, F; Gogoase, M; Coppens, J P; Van Hoof, M
2014-01-01
Morgagni hernia is considered to be the rarest form of all diaphragmatic hernias. It develops through a congenital defect in the retrosternal area. Usually asymptomatic, this entity can lead to life-threatening complications such as incarceration, strangulation or volvulus of the herniated viscus. We hereby report a rare case of organoaxial gastric volvulus producing through the foramen of Morgagni in a 78-year-old woman. The full diagnosis was made by upper gastro-intestinal series and multidetector computed tomography (MDCT). The basic anatomy, physiopathology, diagnostic methods, complications and surgical treatment of Morgagni hernia are briefly reviewed.
Yamashita, Seigo; Sacher, Frédéric; Mahida, Saagar; Berte, Benjamin; Lim, Han S; Komatsu, Yuki; Amraoui, Sana; Denis, Arnaud; Derval, Nicolas; Laurent, François; Montaudon, Michel; Hocini, Mélèze; Haïssaguerre, Michel; Jaïs, Pierre; Cochet, Hubert
2015-04-01
Epicardial ventricular tachycardia (VT) ablation is associated with risks of coronary artery (CA) and phrenic nerve (PN) injury. We investigated the role of multidetector computed tomography in visualizing CA and PN during VT ablation. Ninety-five consecutive patients (86 men; age, 57 ± 15) with VT underwent cardiac multidetector computed tomography. The PN detection rate and anatomic variability were analyzed. In 49 patients undergoing epicardial mapping, real-time multidetector computed tomographic integration was used to display CAs/PN locations in 3-dimensional mapping systems. Elimination of local abnormal ventricular activities (LAVAs) was used as ablation end point. The distribution of CAs/PN with respect to LAVA was analyzed and compared between VT etiologies. Multidetector computed tomography detected PN in 81 patients (85%). Epicardial LAVAs were observed in 44 of 49 patients (15 ischemic cardiomyopathy, 15 nonischemic cardiomyopathy, and 14 arrhythmogenic right ventricular cardiomyopathy) with a mean of 35 ± 37 LAVA points/patient. LAVAs were located within 1 cm from CAs and PN in 35 (80%) and 18 (37%) patients, respectively. The prevalence of LAVA adjacent to CAs was higher in nonischemic cardiomyopathy and arrhythmogenic right ventricular cardiomyopathy than in ischemic cardiomyopathy (100% versus 86% versus 53%; P < 0.01). The prevalence of LAVAs adjacent to PN was higher in nonischemic cardiomyopathy than in ischemic cardiomyopathy (93% versus 27%; P < 0.001). Epicardial ablation was performed in 37 patients (76%). Epicardial LAVAs could not be eliminated because of the proximity to CAs or PN in 8 patients (18%). The epicardial electrophysiological VT substrate is often close to CAs and PN in patients with nonischemic cardiomyopathy. High-resolution image integration is potentially useful to minimize risks of PN and CA injury during epicardial VT ablation. © 2015 American Heart Association, Inc.
Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui
2013-12-01
The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P = 0.25) nor DSA (P = 1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P = 1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.
Akpinar, Erhan; Türkbey, Bariş; Cil, Barbaros Erhan; Canyiğit, Murat; Dündar, Ziya; Balkanci, Ferhun
2007-06-01
Acute lower gastrointestinal system (GIS) bleeding is a life-threatening condition. Immediate determination of the origin of the bleeding is crucial, since hemostatic management must be initiated as rapidly as possible. Colonoscopy, radionuclide studies, and conventional angiography are considered the most important methods for assessing the origin of the bleeding. There are few published reports about the feasibility of computed tomography (CT) in acute GIS bleeding. We present multidetector CT (MDCT) findings in a case of Hodgkin disease status one month post-chemotherapy (CHOP protocol; cyclophosphamide, doxorubicin, vincristine, prednisone) that presented with acute lower GIS bleeding.
Yuksekkaya, Ruken; Ozturk, Banu; Celikyay, Fatih; Sade, Recep; Kupeli, Mustafa; Yeginsu, Ali
2013-01-01
A bronchopleural fistula (BPF) is defined as a direct pathway between the bronchial tree or lung parenchyma and the pleural space. Herein, we describe the clinical findings and imaging results of BPFs in three cases. The patients' medical histories revealed that the first had recurrent pulmonary tuberculosis, the second had small-cell lung cancer (SCLC) and had previously undergone chemoradiotherapy, and the third had trauma. Multidetector computed tomography (MDCT) showed clear communication between the airways and pleural spaces which was sufficient for a proper diagnosis without performing a bronchoscopy. PMID:26029624
Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults
Matos, António P.; Mascarenhas, Vasco; Herédia, Vasco
2014-01-01
Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall. PMID:25295188
Multidetector computer tomography: evaluation of blunt chest trauma in adults.
Palas, João; Matos, António P; Mascarenhas, Vasco; Herédia, Vasco; Ramalho, Miguel
2014-01-01
Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.
Broad ligament hernia successfully treated by laparoscopy: Case report and review of literature.
Matsunami, Masatoshi; Kusanagi, Hiroshi; Hayashi, Ken; Yamada, Shigetoshi; Kano, Nobuyasu
2014-11-01
We report a case of a 36-year-old woman with a history of caesarean section who presented with small bowel obstruction. Abdominal multi-detector CT showed discontinuity of the small bowel near the broad ligament on the left. We made a provisional diagnosis of an internal hernia through a defect in the broad ligament and performed laparoscopic exploration, which revealed a viable ileal loop incarcerated by the broad ligament. Multi-detector CT may be useful for diagnosing this type of defect preoperatively, whereby open surgery can be avoided. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.
Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware.
Vande Berg, Bruno; Malghem, Jacques; Maldague, Baudouin; Lecouvet, Frederic
2006-12-01
Multi-detector CT imaging (MDCT) becomes routine imaging modality in the assessment of the postoperative orthopedic patients with metallic instrumentation that degrades image quality at MR imaging. This article reviews the physical basis and CT appearance of such metal-related artifacts. It also addresses the clinical value of MDCT in postoperative orthopedic patients with emphasis on fracture healing, spinal fusion or arthrodesis, and joint replacement. MDCT imaging shows limitations in the assessment of the bone marrow cavity and of the soft tissues for which MR imaging remains the imaging modality of choice despite metal-related anatomic distortions and signal alteration.
Measurement of positron annihilation lifetimes for positron burst by multi-detector array
NASA Astrophysics Data System (ADS)
Wang, B. Y.; Kuang, P.; Liu, F. Y.; Han, Z. J.; Cao, X. Z.; Zhang, P.
2018-03-01
It is currently impossible to exploit the timing information in a gamma-ray pulse generated within nanoseconds when a high-intensity positron burst annihilation event occurs in a target using conventional single-detector methods. A state-of-the-art solution to the problem is proposed in this paper. In this approach, a multi-detector array composed of many independent detection cells mounted spherically around the target is designed to detect the time distribution of the annihilated gamma rays generated following, in particular, a positron burst emitting huge amounts of positrons in a short pulse duration, even less than a few nano- or picoseconds.
Lee, L.Y.
1973-12-01
A readout system has been provided for reading out a radiation multidetector device with a reduced number of signal sensors. A radiation hodoscope, such as an array of scintillation counters, multiwire proportional counter array, or a set of multidetectors which do not receive signals simultaneously, is divided into equal numbered groups. A first group of signal terminals is connected to the equal numbered groups of detectors so that a signal from any one of the detectors of a group will be fed to one of the first group of terminals. A second group of signal terminals is connected to the detector groups so that a signal from a particular numbered detector of each of the detector groups is connected to one of the second group of terminals. Both groups of signal terminals are, in turn, coupled to signal sensors so that when a signal is simultaneously observed in one of the first group of terminals and one of the second group of tenniinals the specific detector detecting a radiation event is determined. The sensors are arranged in such a manner that a binary code is developed from their outputs which can be stored in a digital storage means according to the location of the event in the multidetector device. (Official Gazette)
Solomon, Justin; Mileto, Achille; Nelson, Rendon C; Roy Choudhury, Kingshuk; Samei, Ehsan
2016-04-01
To determine if radiation dose and reconstruction algorithm affect the computer-based extraction and analysis of quantitative imaging features in lung nodules, liver lesions, and renal stones at multi-detector row computed tomography (CT). Retrospective analysis of data from a prospective, multicenter, HIPAA-compliant, institutional review board-approved clinical trial was performed by extracting 23 quantitative imaging features (size, shape, attenuation, edge sharpness, pixel value distribution, and texture) of lesions on multi-detector row CT images of 20 adult patients (14 men, six women; mean age, 63 years; range, 38-72 years) referred for known or suspected focal liver lesions, lung nodules, or kidney stones. Data were acquired between September 2011 and April 2012. All multi-detector row CT scans were performed at two different radiation dose levels; images were reconstructed with filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction (MBIR) algorithms. A linear mixed-effects model was used to assess the effect of radiation dose and reconstruction algorithm on extracted features. Among the 23 imaging features assessed, radiation dose had a significant effect on five, three, and four of the features for liver lesions, lung nodules, and renal stones, respectively (P < .002 for all comparisons). Adaptive statistical iterative reconstruction had a significant effect on three, one, and one of the features for liver lesions, lung nodules, and renal stones, respectively (P < .002 for all comparisons). MBIR reconstruction had a significant effect on nine, 11, and 15 of the features for liver lesions, lung nodules, and renal stones, respectively (P < .002 for all comparisons). Of note, the measured size of lung nodules and renal stones with MBIR was significantly different than those for the other two algorithms (P < .002 for all comparisons). Although lesion texture was significantly affected by the reconstruction algorithm used (average of 3.33 features affected by MBIR throughout lesion types; P < .002, for all comparisons), no significant effect of the radiation dose setting was observed for all but one of the texture features (P = .002-.998). Radiation dose settings and reconstruction algorithms affect the extraction and analysis of quantitative imaging features in lesions at multi-detector row CT.
Right heart on multidetector CT
Gopalan, D
2011-01-01
Right ventricular function plays an integral role in the pathogenesis and outcome of many cardiovascular diseases. Imaging the right ventricle has long been a challenge because of its complex geometry. In recent years there has been a tremendous expansion in multidetector row CT (MDCT) and its cardiac applications. By judicious modification of contrast medium protocol, it is possible to achieve good opacification of the right-sided cardiac chambers, thereby paving the way for exploring the overshadowed right heart. This article will describe the key features of right heart anatomy, review MDCT acquisition techniques, elaborate the various morphological and functional information that can be obtained, and illustrate some important clinical conditions associated with an abnormal right heart. PMID:22723537
Multi-detector CT angiography of the aortic valve—Part 2: disease specific findings
Ganeshan, Arul
2014-01-01
The aortic valve and adjacent structures should be routinely evaluated on all thoracic cross-sectional imaging studies. Echocardiography and magnetic resonance imaging (MRI) are the main imaging techniques used for assessment of the aortic valve and related pathology but multi-detector computed tomography (MDCT) can offer valuable complimentary information in some clinical scenarios. MDCT is the definite means of assessing aortic valvular calcification, acute aortic syndrome and for non-invasive assessment of the coronary arteries. MDCT also has an emerging role in the planning and follow-up of trans-catheter aortic valve replacement. This article reviews the spectrum of aortic valve disease highlighting the key MDCT imaging features. PMID:25202663
NASA Astrophysics Data System (ADS)
Favalli, A.; Lombardi, M.; MacArthur, D. W.; McCluskey, C.; Moss, C. E.; Paffett, M. T.; Ianakiev, K. D.
2018-01-01
Improving the quality of safeguards measurements at Gas Centrifuge Enrichment Plants while reducing the inspection effort is an important objective given the number of existing and new plants that need to be safeguarded. A useful tool in many safeguards approaches is the on-line monitoring of enrichment in process pipes. One requirement of such a monitor is a simple, reliable and precise passive measurement of the 186-keV line from 235U. The other information required is the amount of gas in the pipe, which can be obtained by a transmission or pressure measurement. We describe our research to develop such a passive measurement system. Unfortunately, a complication arises in the interpretation of the gamma measurements, from the contribution of uranium deposits on the wall of the pipe to the 186-keV peak. A multi-detector approach to address this complication is presented where two measurements, one with signal primarily from gas and one with signal primarily from deposits, are performed simultaneously with different detectors and geometries. This allows a correction to be made to the 186-keV peak for the contribution from the deposit. We present the design of the multi-detector system and the results of the experimental calibration of the proof-of-principle prototype built at LANL.
Bahadir, Osman; Kosucu, Polat
2012-12-01
To objectively assess the efficacy of radiofrequency thermal ablation of inferior turbinate hypertrophy. Thirty-five patients with nasal obstruction secondary to inferior turbinate hypertrophy were prospectively enrolled. Radiofrequency energy was delivered to four sites in each inferior turbinate. Patients were evaluated before and 8 weeks after intervention. Subjective evaluation of nasal obstruction was performed using a visual analogue scale (VAS), and objective evaluation of the turbinate volume reduction was calculated using multidetector CT. Volumetric measurements of the preoperative inferior turbinate were compared with postoperative values on both sides. The great majority of patients (91.4%) exhibited subjective postoperative improvement. Mean obstruction (VAS) improved significantly from 7.45±1.48 to 3.54±1.96. Significant turbinate volume reduction was achieved by the surgery on both right and left sides [(preoperative vs. postoperative, right: 6.55±1.62cm(3) vs. 5.10±1.47cm(3), (P<0.01); left: 6.72±1.53cm(3) vs. 5.00±1.37cm(3), (P<0.01)] respectively. Radiofrequency is a safe and effective surgical procedure in reducing turbinate volume in patients with inferior turbinate hypertrophy. Multidetector CT is an objective method of assessment in detecting radiofrequency turbinate volume reduction. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Diagnostic performance of 64-slice multidetector coronary computed tomographic angiography in women.
Jug, Borut; Gupta, Mohit; Papazian, Jenny; Li, Dong; Tsang, Janet; Bhatia, Harpreet; Karlsberg, Ronald; Budoff, Matthew
2012-12-01
Diagnostic approach to chest pain in women is challenging, but still under-investigated. The purpose of this study was to assess the diagnostic performance of 64-slice multidetector coronary computed tomographic angiography (CCTA) in women with chest pain. We included 606 patients--255 women and 351 men (mean age 61 ± 12 years for both)--who had been referred for a CCTA and an invasive coronary angiography (diagnostic standard) because of chest pain, either as part of clinical work-up in two urban medical centers or as part of the multicenter ACCURACY trial. On a patient-based model, the sensitivity, specificity, and positive predictive value (PPV) and negative predictive value to detect ≥50% and ≥70% stenosis were 98%, 84%, 87%, and 97% and 96%, 83%, 77%, and 97%, respectively, for women and 97%, 83%, 89%, and 95% and 94%, 91%, 90%, and 94%, respectively, for men. There were no statistically significant differences between men and women in diagnostic performance measures except for the PPV of detecting a ≥70% stenosis (P = .007). In women with chest pain, 64-slice multidetector CCTA is at least as sensitive and specific as in men. Our findings suggest that CCTA is a promising diagnostic tool for timely detection and/or exclusion of CAD in symptomatic intermediate-risk female populations.
Multidetector CT evaluation of the postoperative pancreas.
Yamauchi, Fernando I; Ortega, Cinthia D; Blasbalg, Roberto; Rocha, Manoel S; Jukemura, José; Cerri, Giovanni G
2012-01-01
Several pancreatic diseases may require surgical treatment, with most of these procedures classified as resection or drainage. Resection procedures, which are usually performed to remove pancreatic tumors, include pancreatoduodenectomy, central pancreatectomy, distal pancreatectomy, and total pancreatectomy. Drainage procedures are usually performed to treat chronic pancreatitis after the failure of medical therapy and include the Puestow and Frey procedures. The type of surgery depends not only on the patient's symptoms and the location of the disease, but also on the expertise of the surgeon. Radiologists should become familiar with these surgical procedures to better understand postoperative changes in anatomic findings. Multidetector computed tomography is the modality of choice for identifying normal findings after surgery, postoperative complications, and tumor recurrence in patients who have undergone pancreatic surgery. RSNA, 2012
{sup 25}Na and {sup 25}Mg fragmentation on {sup 12}C at 9.23 MeV per nucleon at TRIUMF
DOE Office of Scientific and Technical Information (OSTI.GOV)
St-Onge, Patrick; Boisjoli, Mark; Fregeau, Marc-Olivier
2012-10-20
HERACLES is a multidetector that is used to study heavy-ion collisions, with ion beams with an energy range between 8 to 15 MeV per nucleon. It has 78 detectors axially distributed around the beam axis in 6 rings allowing detection of multiple charged fragments from nuclear reactions. HERACLES has 4 different types of detectors, BC408/BaF{sub 2} phoswich, Si/CsI(Tl) telescope, BC408/BC444 phoswich and CsI(Tl) detectors. The multidetector has been run with a radioactive {sup 25}Na beam and a stable {sup 25}Mg beam at 9.23 MeV per nucleon on a carbon target.
Toroid cavity/coil NMR multi-detector
Gerald, II, Rex E.; Meadows, Alexander D.; Gregar, Joseph S.; Rathke, Jerome W.
2007-09-18
An analytical device for rapid, non-invasive nuclear magnetic resonance (NMR) spectroscopy of multiple samples using a single spectrometer is provided. A modified toroid cavity/coil detector (TCD), and methods for conducting the simultaneous acquisition of NMR data for multiple samples including a protocol for testing NMR multi-detectors are provided. One embodiment includes a plurality of LC resonant circuits including spatially separated toroid coil inductors, each toroid coil inductor enveloping its corresponding sample volume, and tuned to resonate at a predefined frequency using a variable capacitor. The toroid coil is formed into a loop, where both ends of the toroid coil are brought into coincidence. Another embodiment includes multiple micro Helmholtz coils arranged on a circular perimeter concentric with a central conductor of the toroid cavity.
Koren Fernández, L; Alonso Charterina, S; Alcalá-Galiano Rubio, A; Sánchez Nistal, M A
2014-01-01
Pulmonary aspergillosis is a fungal infection usually caused by inhaling Aspergillus fumigatus spores. However, when we talk about aspergillosis, we normally refer to the spectrum of clinical and radiological findings that depend directly on the patient's immune status, on the prior existence of lung disease, and on the virulence of the infective organism. There are four types of pulmonary aspergillosis (aspergilloma, allergic bronchopulmonary aspergillosis, chronic necrotizing pulmonary aspergillosis, and invasive aspergillosis), and each type has its own distinct radiologic findings. We review the signs of pulmonary aspergillosis on multidetector computed tomography and we correlate them with patients' symptoms and immune responses. Likewise, we discuss the differential diagnoses. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
High resolution multidetector CT aided tissue analysis and quantification of lung fibrosis
NASA Astrophysics Data System (ADS)
Zavaletta, Vanessa A.; Karwoski, Ronald A.; Bartholmai, Brian; Robb, Richard A.
2006-03-01
Idiopathic pulmonary fibrosis (IPF, also known as Idiopathic Usual Interstitial Pneumontis, pathologically) is a progressive diffuse lung disease which has a median survival rate of less than four years with a prevalence of 15-20/100,000 in the United States. Global function changes are measured by pulmonary function tests and the diagnosis and extent of pulmonary structural changes are typically assessed by acquiring two-dimensional high resolution CT (HRCT) images. The acquisition and analysis of volumetric high resolution Multi-Detector CT (MDCT) images with nearly isotropic pixels offers the potential to measure both lung function and structure. This paper presents a new approach to three dimensional lung image analysis and classification of normal and abnormal structures in lungs with IPF.
Stojanovska, Jadranka; Ibrahim, El-Sayed H.; Chughtai, Aamer R.; Jackson, Elizabeth A.; Gross, Barry H.; Jacobson, Jon A.; Tsodikov, Alexander; Daneshvar, Brian; Long, Benjamin D.; Chenevert, Thomas L.; Kazerooni, Ella A.
2017-01-01
Intrathoracic fat volume, more specifically, epicardial fat volume, is an emerging imaging biomarker of adverse cardiovascular events. The purpose of this work is to show the feasibility and reproducibility of intrathoracic fat volume measurement applied to contrast-enhanced multidetector computed tomography images. A retrospective cohort study of 62 subjects free of cardiovascular disease (55% females, age = 49 ± 11 years) conducted from 2008 to 2011 formed the study group. Intrathoracic fat volume was defined as all fat voxels measuring −50 to −250 Hounsfield Unit within the intrathoracic cavity from the level of the pulmonary artery bifurcation to the heart apex. The intrathoracic fat was separated into epicardial and extrapericardial fat by tracing the pericardium. The measurements were obtained by 2 readers and compared for interrater reproducibility. The fat volume measurements for the study group were 141 ± 72 cm3 for intrathoracic fat, 58 ± 27 cm3 for epicardial fat, and 84 ± 50 cm3 for extrapericardial fat. There was no statistically significant difference in intrathoracic fat volume measurements between the 2 readers, with correlation coefficients of 0.88 (P = .55) for intrathoracic fat volume and −0.12 (P = .33) for epicardial fat volume. Voxel-based measurement of intrathoracic fat, including the separation into epicardial and extrapericardial fat, is feasible and highly reproducible from multidetector computed tomography scans. PMID:28626797
Omura, Kensuke; Ota, Hideki; Takahashi, Yuuki; Matsuura, Tomonori; Seiji, Kazumasa; Arai, Yoichi; Morimoto, Ryo; Satoh, Fumitoshi; Takase, Kei
2017-03-01
Adrenal venous sampling is the most reliable diagnostic procedure to determine surgical indications in primary aldosteronism. Because guidelines recommend multidetector computed tomography (CT) to evaluate the adrenal gland, some past reports used multidetector CT as a guide for adrenal venous sampling. However, the detailed anatomy of the right adrenal vein and its relationship with an accessory hepatic vein remains uncertain. The purpose of this study was to describe detailed anatomical variations of the right adrenal vein and to determine the concordance between CT and catheter venography in patients with primary aldosteronism. In total, 440 consecutive patients who underwent adrenal venous sampling were included. Four-phase dynamic CT was performed. Anatomical locations and variations of the right adrenal vein and its relationship with the accessory hepatic vein were compared with catheter venographic findings. Successful catheterization was achieved in 437 patients (99%). The right adrenal vein was visualized in the late arterial phase with CT in 420 patients (95%). The right adrenal vein formed a common trunk with the accessory hepatic vein in 87 patients (20%). CT identified the correct craniocaudal level of the orifice in 354 patients (84%). Anatomical variations, location, and angle of inflow of the right adrenal vein based on CT demonstrated high concordance with catheter venography. CT may provide useful information for preparation before adrenal venous sampling. © 2017 American Heart Association, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Favalli, A.; Lombardi, M.; MacArthur, D. W.
Improving the quality of safeguards measurements at Gas Centrifuge Enrichment Plants while reducing the inspection effort is an important objective given the number of existing and new plants that need to be safeguarded. A useful tool in many safeguards approaches is the on-line monitoring of enrichment in process pipes. One requirement of such a monitor is a simple, reliable and precise passive measurement of the 186-keV line from 235U. The other information required is the amount of gas in the pipe, which can be obtained by a transmission or pressure measurement. Here, we describe our research to develop such amore » passive measurement system. Unfortunately, a complication arises in the interpretation of the gamma measurements, from the contribution of uranium deposits on the wall of the pipe to the 186-keV peak. A multi-detector approach to address this complication is presented where two measurements, one with signal primarily from gas and one with signal primarily from deposits, are performed simultaneously with different detectors and geometries. This allows a correction to be made to the 186-keV peak for the contribution from the deposit. Finally, we present the design of the multi-detector system and the results of the experimental calibration of the proof-of-principle prototype built at LANL.« less
Favalli, A.; Lombardi, M.; MacArthur, D. W.; ...
2017-09-14
Improving the quality of safeguards measurements at Gas Centrifuge Enrichment Plants while reducing the inspection effort is an important objective given the number of existing and new plants that need to be safeguarded. A useful tool in many safeguards approaches is the on-line monitoring of enrichment in process pipes. One requirement of such a monitor is a simple, reliable and precise passive measurement of the 186-keV line from 235U. The other information required is the amount of gas in the pipe, which can be obtained by a transmission or pressure measurement. Here, we describe our research to develop such amore » passive measurement system. Unfortunately, a complication arises in the interpretation of the gamma measurements, from the contribution of uranium deposits on the wall of the pipe to the 186-keV peak. A multi-detector approach to address this complication is presented where two measurements, one with signal primarily from gas and one with signal primarily from deposits, are performed simultaneously with different detectors and geometries. This allows a correction to be made to the 186-keV peak for the contribution from the deposit. Finally, we present the design of the multi-detector system and the results of the experimental calibration of the proof-of-principle prototype built at LANL.« less
Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.
Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P
2005-12-01
Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.
Stomach arteriovenous malformation resected by laparoscopy-assisted surgery: A case report.
Hotta, Masahiro; Yamamoto, Kazuhito; Cho, Kazumitsu; Takao, Yoshimune; Fukuoka, Takeshi; Uchida, Eiji
2016-05-01
Arteriovenous malformations of the stomach are an uncommon cause of upper GI bleeding. We report a case of stomach arteriovenous malformation in an 85-year-old Asian man who presented with massive hematemesis. Initial esophagogastroduodenoscopy did not detect this lesion, but contrast multi-detector CT confirmed GI bleeding. Multi-detector CT revealed a mass of blood vessels underlying the submucosa that arose from the right gastroepiploic artery. Repeat esophagogastroduodenoscopy showed that the lesion was a submucosal tumor with erosion and without active bleeding in the lower body of the stomach on the greater curvature. We performed partial gastrectomy via laparoscopy-assisted surgery. The histopathological diagnosis was arteriovenous malformation. © 2016 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
... Computed tomography scan - heart; Calcium scoring; Multi-detector CT scan - heart; Electron beam computed tomography - heart; Agatston ... table that slides into the center of the CT scanner. You will lie on your back with ...
Taylor, Stuart A; Halligan, Steve; Bartram, Clive I; Morgan, Paul R; Talbot, Ian C; Fry, Nicola; Saunders, Brian P; Khosraviani, Kirosh; Atkin, Wendy
2003-10-01
To investigate the effects of orientation, collimation, pitch, and tube current setting on polyp detection at multi-detector row computed tomographic (CT) colonography and to determine the optimal combination of scanning parameters for screening. A colectomy specimen containing 117 polyps of different sizes was insufflated and imaged with a multi-detector row CT scanner at various collimation (1.25 and 2.5 mm), pitch (3 and 6), and tube current (50, 100, and 150 mA) settings. Two-dimensional multiplanar reformatted images and three-dimensional endoluminal surface renderings from the 12 resultant data sets were examined by one observer for the presence and conspicuity of polyps. The results were analyzed with Poisson regression and logistic regression to determine the effects of scanning parameters and of specimen orientation on polyp detection. The percentage of polyps that were detected significantly increased when collimation (P =.008) and table feed (P =.03) were decreased. Increased tube current resulted in improved detection only of polyps with a diameter of less than 5 mm. Polyps of less than 5 mm were optimally depicted with a collimation of 1.25 mm, a pitch of 3, and a tube current setting of 150 mA; polyps with a diameter greater than 5 mm were adequately depicted with 1.25-mm collimation and with either pitch setting and any of the three tube current settings. Small polyps in the transverse segment (positioned at a 90 degrees angle to the z axis of scanning) were significantly less visible than those in parallel or oblique orientations (P <.001). The effective radiation dose, calculated with a Monte Carlo simulation, was 1.4-10.0 mSv. Detection of small polyps (<5 mm) with multi-detector row CT is highly dependent on collimation, pitch, and, to a lesser extent, tube current. Collimation of 1.25 mm, combined with pitch of 6 and tube current of 50 mA, provides for reliable detection of polyps 5 mm or larger while limiting the effective radiation dose. Polyps smaller than 5 mm, however, may be poorly depicted with use of these settings in the transverse colon. Copyright RSNA, 2003
Cardiac Computed Tomography (Multidetector CT, or MDCT)
... other tests, such as chest X-rays , electrocardiograms (ECG) , echocardiograms (echocardiography) , or stress tests , don’t give ... be attached to your chest to monitor your ECG. The ECG is also needed to help the ...
Casula, E; Lonjedo, E; Cerverón, M J; Ruiz, A; Gómez, J
2014-01-01
The increase in the frequency of abdominal aortic aneurysms (AAA) and the widely accepted use of endovascular aneurysm repair (EVAR) as a first-line treatment or as an alternative to conventional surgery make it necessary for radiologists to have thorough knowledge of the pre- and post-treatment findings. The high image quality provided by multidetector computed tomography (MDCT) enables CT angiography to play a fundamental role in the study of AAA and in planning treatment. The objective of this article is to review the cases of AAA in which CT angiography was the main imaging technique, so that radiologists will be able to detect the signs related to this disease, to diagnose it, to plan treatment, and to detect complications in the postoperative period. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.
Collimated prompt gamma TOF measurements with multi-slit multi-detector configurations
NASA Astrophysics Data System (ADS)
Krimmer, J.; Chevallier, M.; Constanzo, J.; Dauvergne, D.; De Rydt, M.; Dedes, G.; Freud, N.; Henriquet, P.; La Tessa, C.; Létang, J. M.; Pleskač, R.; Pinto, M.; Ray, C.; Reithinger, V.; Richard, M. H.; Rinaldi, I.; Roellinghoff, F.; Schuy, C.; Testa, E.; Testa, M.
2015-01-01
Longitudinal prompt-gamma ray profiles have been measured with a multi-slit multi-detector configuration at a 75 MeV/u 13C beam and with a PMMA target. Selections in time-of-flight and energy have been applied in order to discriminate prompt-gamma rays produced in the target from background events. The ion ranges which have been extracted from each individual detector module agree amongst each other and are consistent with theoretical expectations. In a separate dedicated experiment with 200 MeV/u 12C ions the fraction of inter-detector scattering has been determined to be on the 10%-level via a combination of experimental results and simulations. At the same experiment different collimator configurations have been tested and the shielding properties of tungsten and lead for prompt-gamma rays have been measured.
Evaluation of prosthetic valve thrombosis by 64-row multi-detector computed tomography. .
Tarzia, Vincenzo; Bortolussi, Giacomo; Rubino, Maurizio; Gallo, Michele; Bottio, Tomaso; Gerosa, Gino
2015-03-01
Multi-detector computed tomography (MDCT), combined with retrospective electrocardiographic gating, permits cardiac imaging with high accuracy. Recent advances in MDCT have seemed to respond adequately to the need for a non-invasive and reliable assessment of the coronary artery lumen. Two patients with prosthetic aortic valves (one bioprosthetic, one mechanical) presented at the authors' institution with dyspnea and syncopal episodes. MDCT was performed to evaluate thrombus characteristics and exclude coronary artery disease (CAD). Based on the MDCT coronary artery assessment, neither patient underwent preoperative invasive coronary angiography, abolishing the risk of any iatrogenic thrombus fragmentation and subsequent embolization. One patient underwent surgical treatment without complications, while medical therapy was successful in the other case. MDCT can be used for the accurate imaging of thrombi on prosthetic aortic valves, and to correctly assess possible CAD.
Montaudon, M; Desbarats, P; Berger, P; de Dietrich, G; Marthan, R; Laurent, F
2007-01-01
A thickened bronchial wall is the morphological substratum of most diseases of the airway. Theoretical and clinical models of bronchial morphometry have so far focused on bronchial lumen diameter, and bronchial length and angles, mainly assessed from bronchial casts. However, these models do not provide information on bronchial wall thickness. This paper reports in vivo values of cross-sectional wall area, lumen area, wall thickness and lumen diameter in ten healthy subjects as assessed by multi-detector computed tomography. A validated dedicated software package was used to measure these morphometric parameters up to the 14th bronchial generation, with respect to Weibel's model of bronchial morphometry, and up to the 12th according to Boyden's classification. Measured lumen diameters and homothety ratios were compared with theoretical values obtained from previously published studies, and no difference was found when considering dichotomic division of the bronchial tree. Mean wall area, lumen area, wall thickness and lumen diameter were then provided according to bronchial generation order, and mean homothety ratios were computed for wall area, lumen area and wall thickness as well as equations giving the mean value of each parameter for a given bronchial generation with respect to its value in generation 0 (trachea). Multi-detector computed tomography measurements of bronchial morphometric parameters may help to improve our knowledge of bronchial anatomy in vivo, our understanding of the pathophysiology of bronchial diseases and the evaluation of pharmacological effects on the bronchial wall. PMID:17919291
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Xiaohua; Yuan, Huishu; Duan, Jianghui
2013-08-15
Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lungmore » function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.« less
Dong, J; Hayakawa, Y; Kober, C
2014-01-01
When metallic prosthetic appliances and dental fillings exist in the oral cavity, the appearance of metal-induced streak artefacts is not avoidable in CT images. The aim of this study was to develop a method for artefact reduction using the statistical reconstruction on multidetector row CT images. Adjacent CT images often depict similar anatomical structures. Therefore, reconstructed images with weak artefacts were attempted using projection data of an artefact-free image in a neighbouring thin slice. Images with moderate and strong artefacts were continuously processed in sequence by successive iterative restoration where the projection data was generated from the adjacent reconstructed slice. First, the basic maximum likelihood-expectation maximization algorithm was applied. Next, the ordered subset-expectation maximization algorithm was examined. Alternatively, a small region of interest setting was designated. Finally, the general purpose graphic processing unit machine was applied in both situations. The algorithms reduced the metal-induced streak artefacts on multidetector row CT images when the sequential processing method was applied. The ordered subset-expectation maximization and small region of interest reduced the processing duration without apparent detriments. A general-purpose graphic processing unit realized the high performance. A statistical reconstruction method was applied for the streak artefact reduction. The alternative algorithms applied were effective. Both software and hardware tools, such as ordered subset-expectation maximization, small region of interest and general-purpose graphic processing unit achieved fast artefact correction.
Meta-Analysis of Stress Myocardial Perfusion Imaging
2017-06-06
Coronary Disease; Echocardiography; Fractional Flow Reserve, Myocardial; Hemodynamics; Humans; Magnetic Resonance Imaging; Myocardial Perfusion Imaging; Perfusion; Predictive Value of Tests; Single Photon Emission Computed Tomography; Positron Emission Tomography; Multidetector Computed Tomography; Echocardiography, Stress; Coronary Angiography
Tonolini, Massimo
2016-01-01
Inguinal hernia repair (IHR) with prosthetic mesh implantation is the most common procedure in general surgery, and may be performed using either an open or laparoscopic approach. This paper provides an overview of contemporary tension-free IHR techniques and materials, and illustrates the expected postoperative imaging findings and iatrogenic injuries. Emphasis is placed on multidetector CT, which represents the ideal modality to comprehensively visualize the operated groin region and deeper intra-abdominal structures. CT consistently depicts seroma, mesh infections, hemorrhages, bowel complications and urinary bladder injuries, and thus generally provides a consistent basis for therapeutic choice. Since radiologists are increasingly requested to investigate suspected iatrogenic complications, this paper aims to provide an increased familiarity with early CT studies after IHR, including complications and normal postoperative appearances such as focal pseudolesions, in order to avoid misinterpretation and inappropriate management. PMID:27460285
Posterior semicircular canal dehiscence: value of VEMP and multidetector CT.
Vanspauwen, R; Salembier, L; Van den Hauwe, L; Parizel, P; Wuyts, F L; Van de Heyning, P H
2006-01-01
To illustrate that posterior semicircular canal dehiscence can present similarly to superior semicircular canal dehiscence. The symptomatology initially presented as probable Menière's disease evolving into a mixed conductive hearing loss with a Carhart notch-type perceptive component suggestive of otosclerosis-type stapes fixation. A small hole stapedotomy resulted in a dead ear and a horizontal semicircular canal hypofunction. Recurrent incapacitating vertigo attacks developed. Vestibular evoked myogenic potential (VEMP) testing demonstrated intact vestibulocollic reflexes. Additional evaluation with high resolution multidetector computed tomography (MDCT) of the temporal bone showed a dehiscence of the left posterior semicircular canal. Besides superior semicircular canal dehiscence, posterior semicircular canal dehiscence has to be included in the differential diagnosis of atypical Menière's disease and/or low tone conductive hearing loss. The value of performing MDCT before otosclerosis-type surgery is stressed. VEMP might contribute to establishing the differential diagnosis.
Akiba, Tadashi; Marushima, Hideki; Harada, Junta; Kobayashi, Susumu; Morikawa, Toshiaki
2009-01-01
Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. 3D-MDCT imaging is useful for preoperatively understanding the individual thoracic anatomy in lung cancer surgery. This modality can therefore contribute to safer anatomical pulmonary operations, especially in VATS.
Targeted post-mortem computed tomography cardiac angiography: proof of concept.
Saunders, Sarah L; Morgan, Bruno; Raj, Vimal; Robinson, Claire E; Rutty, Guy N
2011-07-01
With the increasing use and availability of multi-detector computed tomography and magnetic resonance imaging in autopsy practice, there has been an international push towards the development of the so-called near virtual autopsy. However, currently, a significant obstacle to the consideration as to whether or not near virtual autopsies could one day replace the conventional invasive autopsy is the failure of post-mortem imaging to yield detailed information concerning the coronary arteries. To date, a cost-effective, practical solution to allow high throughput imaging has not been presented within the forensic literature. We present a proof of concept paper describing a simple, quick, cost-effective, manual, targeted in situ post-mortem cardiac angiography method using a minimally invasive approach, to be used with multi-detector computed tomography for high throughput cadaveric imaging which can be used in permanent or temporary mortuaries.
NASA Astrophysics Data System (ADS)
Martorana, N. S.; Auditore, L.; Berceanu, I.; Cardella, G.; Chatterjee, M. B.; De Luca, S.; De Filippo, E.; Dell'Aquila, D.; Gnoffo, B.; Lanzalone, G.; Lombardo, I.; Maiolino, C.; Norella, S.; Pagano, A.; Pagano, E. V.; Papa, M.; Pirrone, S.; Politi, G.; Porto, F.; Quattrocchi, L.; Rizzo, F.; Russotto, P.; Trifirò, A.; Trimarchi, M.; Verde, G.; Vigilante, M.
2017-11-01
We report on the results obtained by studying nuclear reactions between isotopes of Ca and Ti at 25 MeV/nucleon. We used the multidetector CHIMERA to detect charged reaction products. In particular, we studied two main effects: the isospin diffusion and the isospin drift. In order to study these processes we performed a moving-source analysis on kinetic energy spectra of the isobar nuclei ^{3H} and ^{3He} . This method allows to isolate the emission from the typical sources produced in reactions at Fermi energy: projectile like fragment (PLF), target like fragment (TLF), and mid-velocity (MV) emission. The obtained results are compared to previous experimental investigations and to simulations obtained with CoMD-II model.
Eren, Suat
2010-01-01
Objective: To evaluate the efficacy of multi-detector row CT (MDCT) on pelvic congestion syndrome (PCS), which is often overlooked or poorly visualized with routine imaging examination. Materials and Methods: We evaluated the MDCT features of 40 patients with PCS (mean age, 45 years; range, 29–60 years) using axial, coronal, sagittal, 3D volume-rendered, and Maximum Intensity Projection MIP images. Results: MDCT revealed pelvic varices and ovarian vein dilatations in all patients. Bilateral ovarian vein dilatation was present in 25 patients, and 15 patients had unilateral dilatation. While 12 cases of secondary pelvic varices occurred simultaneously with a retroaortic left renal vein, 10 cases were due solely to a mass obstruction or stenosis of venous structures. Conclusion: MDCT is an effective tool in the evaluation of PCS, and it has more advantages than other imaging modalities. PMID:25610142
de Weerd, Louis; Weum, Sven; Mercer, James B
2009-09-01
The aim of this paper is to evaluate dynamic infrared thermography (DIRT) as a technique to assist in preoperative perforator selection and planning of free deep inferior epigastric perforator (DIEP) flaps. Twenty-seven patients, scheduled for secondary autologous breast reconstruction with either a free DIEP flap or superficial inferior epigastric artery flap, were included in this prospective clinical study. Preoperative mapping of perforators was performed with a hand-held Doppler and DIRT. A multidetector computer tomography scan was additionally carried out in the last 8 patients. In 23 patients a DIEP flap was used. The perforator as selected from DIRT was a suitable perforator in all DIEP flaps. The location and quality of the selected perforator from DIRT corresponded well with the multidetector computer tomography scan results. Preoperative perforator selection and planning of DIEP flaps is facilitated with the use of DIRT. The technique is noninvasive and easy to use.
Aubry, S; Pousse, A; Sarliève, P; Laborie, L; Delabrousse, E; Kastler, B
2006-11-01
To model vertebrae in 3D to improve radioanatomic knowledge of the spine with the vascular and nerve environment and simulate CT-guided interventions. Vertebra acquisitions were made with multidetector CT. We developed segmentation software and specific viewer software using the Delphi programming environment. This segmentation software makes it possible to model 3D high-resolution segments of vertebrae and their environment from multidetector CT acquisitions. Then the specific viewer software provides multiplanar reconstructions of the CT volume and the possibility to select different 3D objects of interest. This software package improves radiologists' radioanatomic knowledge through a new 3D anatomy presentation. Furthermore, the possibility of inserting virtual 3D objects in the volume can simulate CT-guided intervention. The first volumetric radioanatomic software has been born. Furthermore, it simulates CT-guided intervention and consequently has the potential to facilitate learning interventions using CT guidance.
Current role of multidetector computed tomography in imaging of wrist injuries.
Syed, Mohd Arif; Raj, Vimal; Jeyapalan, Kanagaratnam
2013-01-01
Imaging of the wrist is challenging to both radiologists and orthopedic surgeons. This is primarily because of the complex anatomy/functionality of the wrist and also the fact that many frequent injuries are sustained to the hands. On going developments in multidetector computed tomography (MDCT) technology with its "state of the art" postprocessing capabilities have revolutionized this field. Apart from routine imaging of wrist trauma, it is now possible to assess intrinsic ligaments with MDCT arthrography, thereby avoiding invasive diagnostic arthroscopies. Postoperative wrist imaging can be a diagnostic challenge, and MDCT can be helpful in assessment of these cases because volume acquisition and excellent postprocessing abilities help to evaluate these wrists in any desired plane and thinner slices. This article pictorially reviews the current clinical role of MDCT imaging of wrist in our practice. It also describes arthrography technique and scanning parameters used at our center. Copyright © 2013 Mosby, Inc. All rights reserved.
Recent technologic advances in multi-detector row cardiac CT.
Halliburton, Sandra Simon
2009-11-01
Recent technical advances in multi-detector row CT have resulted in lower radiation dose, improved temporal and spatial resolution, decreased scan time, and improved tissue differentiation. Lower radiation doses have resulted from the use of pre-patient z collimators, the availability of thin-slice axial data acquisition, the increased efficiency of ECG-based tube current modulation, and the implementation of iterative reconstruction algorithms. Faster gantry rotation and the simultaneous use of two x-ray sources have led to improvements in temporal resolution, and gains in spatial resolution have been achieved through application of the flying x-ray focal-spot technique in the z-direction. Shorter scan times have resulted from the design of detector arrays with increasing numbers of detector rows and through the simultaneous use of two x-ray sources to allow higher helical pitch. Some improvement in tissue differentiation has been achieved with dual energy CT. This article discusses these recent technical advances in detail.
Ye, Feng; Liu, Jun; Ouyang, Han
2015-08-01
The purpose of this meta-analysis was to compare the diagnostic accuracy of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and multidetector-row computed tomography (MDCT) for hepatocellular carcinoma (HCC).Medline, Cochrane, EMBASE, and Google Scholar databases were searched until July 4, 2014, using combinations of the following terms: gadoxetic acid disodium, Gd-EOB-DTPA, multidetector CT, contrast-enhanced computed tomography, and magnetic resonance imaging. Inclusion criteria were as follows: confirmed diagnosis of primary HCC by histopathological examination of a biopsy specimen; comparative study of MRI using Gd-EOB-DTPA and MDCT for diagnosis of HCC; and studies that provided quantitative outcome data. The pooled sensitivity and specificity of the 2 methods were compared, and diagnostic accuracy was assessed with alternative-free response receiver-operating characteristic analysis.Nine studies were included in the meta-analysis, and a total of 1439 lesions were examined. The pooled sensitivity and specificity for 1.5T MRI were 0.95 and 0.96, respectively, for 3.0T MRI were 0.91 and 0.96, respectively, and for MDCT were 0.74 and 0.93, respectively. The pooled diagnostic odds ratio for 1.5T and 3.0T MRI was 242.96, respectively, and that of MDCT was 33.47. To summarize, Gd-EOB-DTPA-enhanced MRI (1.5T and 3.0T) has better diagnostic accuracy for HCC than MDCT.
Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook
2009-01-01
To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.
Penetrating Colorectal Injuries: Diagnostic Performance of Multidetector CT with Trajectography.
Dreizin, David; Boscak, Alexis R; Anstadt, Michael J; Tirada, Nikki; Chiu, William C; Munera, Felipe; Bodanapally, Uttam K; Hornick, Michael; Stein, Deborah M
2016-12-01
Purpose To determine the diagnostic performance of multidetector computed tomography (CT) with trajectography for penetrating colorectal injuries. Materials and Methods This institutional review board-approved and HIPAA-compliant study was a 6-year blinded retrospective review by two independent readers of 182 consecutive patients who preoperatively underwent 40- or 64-row multidetector CT for penetrating torso trauma below the diaphragm and had surgically confirmed findings. Colorectal perforation was present in 42 patients. Trajectory analysis with postprocessing software was used for all studies. Additional signs evaluated were rectal contrast agent leak, collections of extruded fecal material, mural defect, wall thickening, abnormal enhancement, free fluid or stranding, and free air. The quality of the colorectal contrast agent administration was recorded. Sensitivity, specificity, predictive values, areas under the receiver operating characteristic curves (AUCs), and Cohen κ were determined. Results In patients with rectal contrast agent administration (n = 151), AUCs were 0.90-0.91, which indicated excellent accuracy. Trajectory was sensitive (88%-91%). For single wounds (n = 104), sensitivity of trajectory was 96% for both readers, but was only 80% for multiple wounds (n = 47). Contrast agent leak was highly specific (96%-98%), but insensitive (42%-46%). Improved diagnostic performance was observed in patients with poor colonic distension or opacification. Accuracy remained high (AUC, 0.86-0.99) in the group without rectal contrast agent administration (n = 31). Conclusion Trajectory had excellent sensitivity, while rectal contrast agent leak was specific but insensitive. Sensitivity of trajectory was lower for multiple wounds. Accuracy remained high in patients without rectal contrast agent administration. © RSNA, 2016.
Use of multidetector computed tomography in the assessment of dogs with pericardial effusion.
Scollan, K F; Bottorff, B; Stieger-Vanegas, S; Nemanic, S; Sisson, D
2015-01-01
Contrast-enhanced multidetector computed tomography (MDCT) allows high spatial and temporal resolution imaging of cardiac, thoracic, and abdominal structures. Accurate determination of the cause of pericardial effusion (PE) is essential to providing appropriate treatment and prognosis. Echocardiography and pericardial fluid analysis may not differentiate between causes of PE and cannot identify extracardiac metastasis. Describe the thoracic and abdominal MDCT findings and evaluate the utility of MDCT to differentiate between neoplastic and nonneoplastic causes of PE in dogs. Eleven client-owned dogs with PE diagnosed by echocardiography. Prospective observational study. Transthoracic echocardiography (TTE), 3-view thoracic radiography, and contrast-enhanced thoracic and abdominal MDCT images were evaluated for the presence of cardiac masses, pulmonary metastases, and abdominal masses. Histopathology in 5 dogs and survival analysis in all dogs were evaluated. A neoplastic cause was identified in 6/11 dogs and a nonneoplastic cause was identified in 5/11. Cardiac MDCT findings were consistent with TTE findings in all dogs with right atrial (5/5) and heart base masses (1/1). Pulmonary metastases were identified in 1/11 dogs by thoracic radiography and in 2/11 dogs by MDCT. MDCT identified splenic or hepatic lesions consistent with neoplasia in 6/11 and 5/11 dogs, respectively. Focal MDCT pericardial changes at the pericardiocentesis site were noted in 3/11 dogs. Multidetector computed tomography did not improve the detection of cardiac masses in dogs with PE over echocardiography. The benefit of MDCT was primarily in the detection of pulmonary metastases and extracardiac lesions using a single imaging modality. Copyright © 2014 by the American College of Veterinary Internal Medicine.
Basak, Muzaffer; Ozkurt, Huseyin; Tanriverdi, Orhan; Cay, Esra; Aydin, Mustafa; Miroglu, Cengiz
2009-01-01
The purpose of this study was to evaluate the use of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with suspected bladder tumors and histories of bladder carcinoma operation. Thirty-six patients (29 men and 7 women) with a mean age of 66 years (range, 24-88 years) with suspected bladder tumors and histories of bladder carcinoma operation were included in this prospective study. Virtual cystoscopy was performed by 16-slice multidetector CT scanner. The bladder was filled with diluted contrast material solution through a Foley catheter. Then, all patients underwent conventional cystoscopy examination. Two reviewers found 18 lesions detected by virtual cystoscopy by consensus, whereas 19 lesions were depicted by conventional cystoscopy. At virtual and conventional cystoscopies, the conditions of 3 patients, 2 with chronic inflammations and 1 with foreign body reaction, were wrongly diagnosed as tumors. At conventional cystoscopy, one patient's result was wrongly interpreted as normal. In pathologic evaluation, all tumors were diagnosed as transitional cell carcinoma. Bladder tumor can be noninvasively diagnosed using virtual cystoscopy. Use of virtual cystoscopy should be considered inpatients who present with hematuria or have histories of bladder carcinoma operation and are for follow-up because of its lesser complication risk and its being a less invasive, easily applied procedure without need of anesthesia. In the future, owing to the development of the CT technology and image processing technique, virtual cystoscopy may have a part in the detection of bladder cancer.
Koizumi, Hiroshi; Sur, Jaideep; Seki, Kenji; Nakajima, Koh; Sano, Tsukasa; Okano, Tomohiro
2010-08-01
To assess effects of dose reduction on image quality in evaluating maxilla and mandible for pre-surgical implant planning using cadavers. Six cadavers were used for the study using multi-detector computed tomography (CT) operated at 120 kV and the variable tube current of 80, 40, 20 and 10 mA. A slice thickness of 0.625 mm and pitch 1 were used. Multi-planar images perpendicular and parallel to dentitions were created. The images were evaluated by five oral radiologists in terms of visibility of the anatomical landmarks including alveolar crest, mandibular canal, floors of the maxillary sinus and nasal cavity, contours/cortical layer of jaw bones and the details of trabecular bone. Observers were asked to determine the quality of the images in comparison with 80 mA images based on the criteria: excellent, good, fair or non-diagnostic. The average scores of all observers were calculated for each specimen in all exposure conditions. The 40 mA images could visualize such landmarks and were evaluated to be same or almost equivalent in quality to the 80 mA images. Even the 20 mA images could be accepted just for diagnostic purpose for implant with substantial deterioration of the image quality. The 10 mA images may not be accepted because of the obscured contour caused by image noise. Significant dose reduction by lowering mA can be utilized for pre-surgical implant planning in multi-detector CT.
Raza, Mushahid; Elkhodair, Samer; Zaheer, Asif; Yousaf, Sohail
2013-11-01
A true gold standard to rule out a significant cervical spine injury in subset of blunt trauma patients with altered sensorium is still to be agreed upon. The objective of this study is to determine whether in obtunded adult patients with blunt trauma, a clinically significant injury to the cervical spine be ruled out on the basis of a normal multidetector cervical spine computed tomography. Comprehensive database search was conducted to include all the prospective and retrospective studies on blunt trauma patients with altered sensorium undergoing cervical spine multidetector CT scan as core imaging modality to "clear" the cervical spine. The studies used two main gold standards, magnetic resonance imaging of the cervical spine and/or prolonged clinical follow-up. The data was extracted to report true positive, true negatives, false positives and false negatives. Meta-analysis of sensitivity, specificity, negative and positive predictive values was performed using Meta Analyst Beta 3.13 software. We also performed a retrospective investigation comparing a robust clinical follow-up and/or cervical spine MR findings in 53 obtunded blunt trauma patients, who previously had undergone a normal multidetector CT scan of the cervical spine reported by a radiologist. A total of 10 studies involving 1850 obtunded blunt trauma patients with initial cervical spine CT scan reported as normal were included in the final meta-analysis. The cumulative negative predictive value and specificity of cervical spine CT of the ten studies was 99.7% (99.4-99.9%, 95% confidence interval). The positive predictive value and sensitivity was 93.7% (84.0-97.7%, 95% confidence interval). In the retrospective review of our obtunded blunt trauma patients, none was later diagnosed to have significant cervical spine injury that required a change in clinical management. In a blunt trauma patient with altered sensorium, a normal cervical spine CT scan is conclusive to safely rule out a clinically significant cervical spine injury. The results of this meta-analysis strongly support the removal of cervical precautions in obtunded blunt trauma patient after normal cervical spine computed tomography. Any further imaging like magnetic resonance imaging of the cervical spine should be performed on case-to-case basis. Copyright © 2013 Elsevier Ltd. All rights reserved.
Positron Scanner for Brain Tumors
DOE R&D Accomplishments Database
Robertson, J. S.; Bozzo, S. R.
1964-10-09
It was thought that if a multi-detector device could be developed, the scanning time would be greatly shortened, with such consequent advantages as being able to work with lower dose of radiation, to obtain serial determinations, and to work with shorter-lived isotopes.
NASA Astrophysics Data System (ADS)
Tarasov, A. P.; Egorov, A. I.; Rogatkin, D. A.
2017-07-01
Using multidetector computed tomography, thicknesses of bone squame and soft tissues of human head were assessed. MC simulation revealed impropriety of source-detector separation distances for 3 oximeters, which can cause extracerebral contamination.
Femoral head avascular necrosis: a frequently missed incidental finding on multidetector CT.
Barille, M F; Wu, Jim S; McMahon, Colm J
2014-03-01
To determine the incidence of missed femoral head avascular necrosis (AVN) on pelvic computed tomography (CT) performed for clinical indications other than assessment for AVN. The study was a Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study. The picture archiving and communication system (PACS) database was queried for patients with diagnosis of femoral head AVN on magnetic resonance imaging (MRI), who also underwent pelvic multidetector CT after or <30 days before the MRI examination. The MRI and CT images of 144 hips of 72 patients (39 patients with reported AVN on MRI and 33 age-matched controls; mean age = 60 years, 28 male, 44 female), were reviewed in consensus by two readers in a randomized, blinded manner. Using MRI-proven CT-visible AVN as a reference standard, the incidence of missed AVN on initial CT interpretation was determined. Readers confirmed AVN in 33 patients on the MRI images. Nine hips with AVN underwent joint replacement of the affected joint(s) prior to subsequent CT and were excluded. Forty-three MRI-proven AVN cases in 28 patients (15 bilateral, 13 unilateral) were available for analysis. The study readers diagnosed 35/43 (81%) MRI-proven AVN cases in 22/28 (79%) patients. Four of the 35 (11%) cases of MRI-proven, CT-visible AVN were prospectively reported in 3/22 (14%) patients at initial clinical interpretation, with a miss rate of 89% per hip and 86% per patient. Multidetector CT has high accuracy for detection of AVN; however, this is frequently missed as an incidental finding (89% missed in the present study). Assessment for signs of femoral AVN should be part of routine search pattern in interpretation of pelvic CT. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Characterization of the Left-Sided Substrate in Arrhythmogenic Right Ventricular Cardiomyopathy.
Berte, Benjamin; Denis, Arnaud; Amraoui, Sana; Yamashita, Seigo; Komatsu, Yuki; Pillois, Xavier; Sacher, Frédéric; Mahida, Saagar; Wielandts, Jean-Yves; Sellal, Jean-Marc; Frontera, Antonio; Al Jefairi, Nora; Derval, Nicolas; Montaudon, Michel; Laurent, François; Hocini, Mélèze; Haïssaguerre, Michel; Jaïs, Pierre; Cochet, Hubert
2015-12-01
The correlates of left ventricular (LV) substrate in arrhythmogenic right ventricular (RV) cardiomyopathy are largely unknown. Thirty-two patients with arrhythmogenic RV cardiomyopathy (47±14 years; 6 women) were included. RV and LV dysplasia were defined from multidetector computed tomography and cardiac magnetic resonance imaging. Arrhythmias were characterized as right-sided or left-sided on 12-lead ECG recordings at baseline and during isoproterenol testing. In 14 patients, the imaging substrate was compared with voltage mapping and local abnormal ventricular activity. Imaging abnormalities were found in 32 (100%) and 21 (66%) patients on the RV and LV, respectively, intramyocardial fat on multidetector computed tomography being the most sensitive feature. LV involvement related to none of the Task Force criteria. Right-sided arrhythmias were more frequent than left-sided arrhythmias (P=0.003) although the latter were more frequent in case of LV involvement (P=0.02). The agreement between low voltage and fat on multidetector computed tomography was high on the RV when using either endocardial unipolar or epicardial bipolar data (κ=0.82 and κ=0.78, respectively) but lower on the LV (κ=0.54 for epicardial bipolar). LV local abnormal ventricular activity was found in all patients with LV involvement, and none of the others. The density of local abnormal ventricular activity within fat areas was similar between the RV and LV (P=0.57). LV substrate is frequent in arrhythmogenic RV cardiomyopathy, but poorly identified by current diagnostic strategies. Left-sided arrhythmias are more frequent in case of LV involvement. LV fat hosts the same density of local abnormal ventricular activity as RV fat, but is less efficiently detected by voltage mapping. These results support the need for alternative diagnostic strategies to identify LV dysplasia. © 2015 American Heart Association, Inc.
Williams, Michelle C; Golay, Saroj K; Hunter, Amanda; Weir-McCall, Jonathan R; Mlynska, Lucja; Dweck, Marc R; Uren, Neal G; Reid, John H; Lewis, Steff C; Berry, Colin; van Beek, Edwin J R; Roditi, Giles; Newby, David E; Mirsadraee, Saeed
2015-01-01
Introduction Observer variability can influence the assessment of CT coronary angiography (CTCA) and the subsequent diagnosis of angina pectoris due to coronary heart disease. Methods We assessed 210 CTCAs from the Scottish COmputed Tomography of the HEART (SCOT-HEART) trial for intraobserver and interobserver variability. Calcium score, coronary angiography and image quality were evaluated. Coronary artery disease was defined as none (<10%), mild (10–49%), moderate (50–70%) and severe (>70%) luminal stenosis and classified as no (<10%), non-obstructive (10–70%) or obstructive (>70%) coronary artery disease. Post-CTCA diagnosis of angina pectoris due to coronary heart disease was classified as yes, probable, unlikely or no. Results Patients had a mean body mass index of 29 (28, 30) kg/m2, heart rate of 58 (57, 60)/min and 62% were men. Intraobserver and interobserver agreements for the presence or absence of coronary artery disease were excellent (95% agreement, κ 0.884 (0.817 to 0.951) and good (91%, 0.791 (0.703 to 0.879)). Intraobserver and interobserver agreement for the presence or absence of angina pectoris due to coronary heart disease were excellent (93%, 0.842 (0.918 to 0.755) and good (86%, 0.701 (0.799 to 0.603)), respectively. Observer variability of calcium score was excellent for calcium scores below 1000. More segments were categorised as uninterpretable with 64-multidetector compared to 320-multidetector CTCA (10.1% vs 2.6%, p<0.001) but there was no difference in observer variability. Conclusions Multicentre multidetector CTCA has excellent agreement in patients under investigation for suspected angina due to coronary heart disease. Trial registration number NCT01149590. PMID:26019881
Yi, Ji Sook; Han, Jong Kyu; Kim, Hyun-Joo
2015-01-01
Objective To assess inter-modality variability when evaluating cervical intervertebral disc herniation using 64-slice multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI). Materials and Methods Three musculoskeletal radiologists independently reviewed cervical spine 1.5-T MRI and 64-slice MDCT data on C2-3 though C6-7 of 51 patients in the context of intervertebral disc herniation. Interobserver and inter-modality agreements were expressed as unweighted kappa values. Weighted kappa statistics were used to assess the extents of agreement in terms of the number of involved segments (NIS) in disc herniation and epicenter measurements collected using MDCT and MRI. Results The interobserver agreement rates upon evaluation of disc morphology by the three radiologists were in fair to moderate agreement (k = 0.39-0.53 for MDCT images; k = 0.45-0.56 for MRIs). When the disc morphology was categorized into two and four grades, the inter-modality agreement rates were moderate (k-value, 0.59) and substantial (k-value, 0.66), respectively. The inter-modality agreements for evaluations of the NIS (k-value, 0.78) and the epicenter (k-value, 0.79) were substantial. Also, the interobserver agreements for the NIS (CT; k-value, 0.85 and MRI; k-value, 0.88) and epicenter (CT; k-value, 0.74 and MRI; k-value, 0.70) evaluations by two readers were substantial. MDCT tended to underestimate the extent of herniated disc lesions compared with MRI. Conclusion Multidetector-row computed tomography and MRI showed a moderate-to-substantial degree of inter-modality agreement for the assessment of herniated cervical discs. MDCT images have a tendency to underestimate the anterior/posterior extent of the herniated disc compared with MRI. PMID:26175589
[Evaluation of cardiac tumors by multidetector computed tomography and magnetic resonance imaging].
Mercado-Guzman, Marcela P; Meléndez-Ramírez, Gabriela; Castillo-Castellon, Francisco; Kimura-Hayama, Eric
Cardiac tumors, are a rare pathology (0.002-0.3%) in all age groups, however, they have a clinic importance, due the affected organ. They are classified in primary (benign or malignant) and secondary (metastasis) types. Among primary type, mixoma, is the most common benign tumor, and sarcoma represents most of the malignant injuries. Cardiac metastasis are more frequent than primary tumors. Clinic effects of cardiac tumors are unspecific and vary according their location, size and agresivity. The use of Multidetector Computed Tomography (MDCT) and Magnetic Resonance Imaging (MRI) assist on the location, sizing, anatomical relationships and the compromise of adyacents structures, besides, MRI is useful for tissue characterization of the tumor. Due to the previous reasons, studies based on noninvasive cardiovascular imaging, have an important role on the characterization of these lesions and the differential diagnosis among them. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.
Kakimoto, Naoya; Chindasombatjaroen, Jira; Tomita, Seiki; Shimamoto, Hiroaki; Uchiyama, Yuka; Hasegawa, Yoko; Kishino, Mitsunobu; Murakami, Shumei; Furukawa, Souhei
2013-01-01
The purpose of this study was to investigate the usefulness of computerized tomography (CT), particularly contrast-enhanced CT, in differentiation of jaw cysts and cystic-appearing tumors. We retrospectively analyzed contrast-enhanced CT images of 90 patients with odontogenic jaw cysts or cystic-appearing tumors. The lesion size and CT values were measured and the short axis to long axis (S/L) ratio, contrast enhancement (CE) ratio, and standard deviation ratio were calculated. The lesion size and the S/L ratio of keratocystic odontogenic tumors were significantly different from those of radicular cysts and follicular cysts. There were no significant differences in the CE ratio among the lesions. Multidetector CT provided diagnostic information about the size of odontogenic cysts and cystic-appearing tumors of the jaws that was related to the lesion type, but showed no relation between CE ratio and the type of these lesions. Copyright © 2013 Elsevier Inc. All rights reserved.
Jones, Blake C; Lipson, Evan J; Childers, Brandon; Fishman, Elliot K; Johnson, Pamela T
The incidence of melanoma has risen dramatically over the past several decades. Oncologists rely on the ability of radiologists to identify subtle radiographic changes representing metastatic and recurrent melanoma in uncommon locations on multidetector computed tomography (MDCT) as the front-line imaging surveillance tool. To accomplish this goal, MDCT acquisition and display must be optimized and radiologist interpretation and search patterns must be tailored to identify the unique and often subtle metastatic lesions of melanoma. This article describes MDCT acquisition and display techniques that optimize the visibility of melanoma lesions, such as high-contrast display windows and multiplanar reconstructions. In addition, innovative therapies for melanoma, such as immunotherapy and small-molecule therapy, have altered clinical management and outcomes and have also changed the spectrum of therapeutic complications that can be detected on MDCT. Recent advances in melanoma therapy and potential complications that the radiologist can identify on MDCT are reviewed.
Latest results and perspectives of the KASCADE-Grande EAS Facility
NASA Astrophysics Data System (ADS)
Haungs, A.; Apel, W. D.; Arteaga-Velázquez, J. C.; Bekk, K.; Bertaina, M.; Blümer, J.; Bozdog, H.; Brancus, I. M.; Buchholz, P.; Cantoni, E.; Chiavassa, A.; Cossavella, F.; Daumiller, K.; de Souza, V.; di Pierro, F.; Doll, P.; Engel, R.; Engler, J.; Finger, M.; Fuhrmann, D.; Ghia, P. L.; Gils, H. J.; Glasstetter, R.; Grupen, C.; Heck, D.; Hörandel, J. R.; Huege, T.; Isar, P. G.; Kampert, K.-H.; Kang, D.; Kickelbick, D.; Klages, H. O.; Link, K.; Łuczak, P.; Ludwig, M.; Mathes, H. J.; Mayer, H. J.; Melissas, M.; Milke, J.; Mitrica, B.; Morello, C.; Navarra, G.; Nehls, S.; Oehlschläger, J.; Ostapchenko, S.; Over, S.; Palmieri, N.; Petcu, M.; Pierog, T.; Rebel, H.; Roth, M.; Schieler, H.; Schröder, F. G.; Sima, O.; Toma, G.; Trinchero, G. C.; Ulrich, H.; Weindl, A.; Wochele, J.; Wommer, M.; Zabierowski, J.
2012-01-01
KASCADE-Grande is a multi-detector experiment at KIT (Karlsruhe Institute of Technology) in Germany for measuring extensive air showers in the primary energy range of 100 TeV to 1 EeV. This paper does not provide a synopsis of all results of the KASCADE-Grande experiment. Rather it is focused on three aspects of current interests illustrating the advantages of a multi-detector facility. Results on the analysis of individual energy spectra of primary mass groups around the knee obtained by unfolding the shower size measurements of KASCADE with the help of the new hadronic interaction model EPOS and the all-particle energy spectrum at higher energies obtained by Grande measurements will be discussed. As KASCADE-Grande serves also as host of the LOPES radio detection experiment where both experiments measure the same showers, special emphasis will be given in comparing the characteristics and feasibility of both techniques in estimating the main parameters of high-energy primary cosmic rays: energy, composition, and arrival direction.
Zhu, Chengcheng; Patterson, Andrew J; Thomas, Owen M; Sadat, Umar; Graves, Martin J; Gillard, Jonathan H
2013-04-01
Luminal stenosis is used for selecting the optimal management strategy for patients with carotid artery disease. The aim of this study is to evaluate the reproducibility of carotid stenosis quantification using manual and automated segmentation methods using submillimeter through-plane resolution Multi-Detector CT angiography (MDCTA). 35 patients having carotid artery disease with >30 % luminal stenosis as identified by carotid duplex imaging underwent contrast enhanced MDCTA. Two experienced CT readers quantified carotid stenosis from axial source images, reconstructed maximum intensity projection (MIP) and 3D-carotid geometry which was automatically segmented by an open-source toolkit (Vascular Modelling Toolkit, VMTK) using NASCET criteria. Good agreement among the measurement using axial images, MIP and automatic segmentation was observed. Automatic segmentation methods show better inter-observer agreement between the readers (intra-class correlation coefficient (ICC): 0.99 for diameter stenosis measurement) than manual measurement of axial (ICC = 0.82) and MIP (ICC = 0.86) images. Carotid stenosis quantification using an automatic segmentation method has higher reproducibility compared with manual methods.
Controversies in imaging of hepatocellular carcinoma: multidetector CT (MDCT)
Silverman, Paul M; Szklaruk, Janio
2005-01-01
Primary hepatocellular carcinoma (HCC) is a significant tumor worldwide and represents the most common primary hepatic neoplasm. Staging criteria are important for appreciation of timely work up of these neoplasms in contradiction with surgical colleagues. This article demonstrates the appearance of HCC on multiphasic, multidetector CT (MDCT) and relates these findings to current staging criteria. The variable appearance on different planes of contrast is critical to appreciate in staging this neoplasm. The hypervascular nature of the primary tumor makes MDCT and three-phase imaging a critical feature in the detection and characterization of this tumor. This is especially critical in the patients who are candidates for surgical resection. Additionally, MDCT has allowed arterial phase imaging to define the vascular supply of the tumor. An accurate representation of the size and number of lesions is critical in not only the initial staging but also the follow-up of hepatocellular carcinoma. The post-treatment features including the appearance post-surgically and after radiofrequency ablation can be well appreciated on MDCT. PMID:16361147
Acute Perforated Diverticulitis: Assessment With Multidetector Computed Tomography.
Sessa, Barbara; Galluzzo, Michele; Ianniello, Stefania; Pinto, Antonio; Trinci, Margherita; Miele, Vittorio
2016-02-01
Colonic diverticulitis is a common condition in the western population. Complicated diverticulitis is defined as the presence of extraluminal air or abscess, peritonitis, colon occlusion, or fistulas. Multidetector row computed tomography (MDCT) is the modality of choice for the diagnosis and the staging of diverticulitis and its complications, which enables performing an accurate differential diagnosis and addressing the patients to a correct management. MDCT is accurate in diagnosing the site of perforation in approximately 85% of cases, by the detection of direct signs (focal bowel wall discontinuity, extraluminal gas, and extraluminal enteric contrast) and indirect signs, which are represented by segmental bowel wall thickening, abnormal bowel wall enhancement, perivisceral fat stranding of fluid, and abscess. MDCT is accurate in the differentiation from complicated colon diverticulitis and colon cancer, often with a similar imaging. The computed tomography-guided classification is recommended to discriminate patients with mild diverticulitis, generally treated with antibiotics, from those with severe diverticulitis with a large abscess, which may be drained with a percutaneous approach. Copyright © 2016 Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Molar mass averages, distributions, and architectural information of polymers are routinely obtained using size-exclusion chromatography (SEC). It has previously been shown that ultrahigh molar mass polymers may experience degradation during SEC analysis, leading to inaccurate molar mass averages a...
Abernethy malformation with portal vein aneurysm in a child.
Chandrashekhara, Sheragaru H; Bhalla, Ashu Seith; Gupta, Arun Kumar; Vikash, C S; Kabra, Susheel Kumar
2011-01-01
Abernethy malformation is an extremely rare anomaly of the splanchnic venous system. We describe multidetector computed tomography findings of an incidentally detected Abernethy malformation with portal vein aneurysm in a two-and-half-year old child. The computed tomography scan was performed for the evaluation of respiratory distress, poor growth, and loss of appetite.
NASA Astrophysics Data System (ADS)
Belinato, W.; Santos, W. S.; Paschoal, C. M. M.; Souza, D. N.
2015-06-01
The combination of positron emission tomography (PET) and computed tomography (CT) has been extensively used in oncology for diagnosis and staging of tumors, radiotherapy planning and follow-up of patients with cancer, as well as in cardiology and neurology. This study determines by the Monte Carlo method the internal organ dose deposition for computational phantoms created by multidetector CT (MDCT) beams of two PET/CT devices operating with different parameters. The different MDCT beam parameters were largely related to the total filtration that provides a beam energetic change inside the gantry. This parameter was determined experimentally with the Accu-Gold Radcal measurement system. The experimental values of the total filtration were included in the simulations of two MCNPX code scenarios. The absorbed organ doses obtained in MASH and FASH phantoms indicate that bowtie filter geometry and the energy of the X-ray beam have significant influence on the results, although this influence can be compensated by adjusting other variables such as the tube current-time product (mAs) and pitch during PET/CT procedures.
Facenda, Catherine; Vaz, Nuno; Castañeda, Edgar Augusto; del Amo, Montserrat; Garcia-Diez, Ana Isabel; Pomes, Jaime
2017-01-01
Blunt injuries to the chest wall are an important chapter on emergency room (ER) departments, being the third most common injuries in trauma patients which ominous complications could appear. This article describes different types of traumatic events affecting the chest wall, which maybe misdiagnosed with conventional X-ray. Special emphasis has been done in computed tomography (CT) and multidetector CT (MDCT) imaging. This technique is considered the “gold-standard” for those traumatic patients, due to its fast acquisition covering the whole area of interest in axial plane, reconstructing multiplanar (2D, 3D) volume-rendered images with a superb quality and angiographic CT capabilities for evaluating vascular damage. Complementary techniques such as ultrasonography (US) and magnetic resonance imaging (MRI) may improve the diagnostic accuracy due to its great capacity in visualising soft-tissue trauma (muscle-tendinous tears) and subtle fractures. All these imaging methods have an important role in quantifying the severity of chest wall trauma. The findings of this study have been exposed with cases of our archives in a didactic way. PMID:28932697
Keles, Papatya; Yuce, Ihsan; Keles, Sait; Kantarci, Mecit
2016-06-01
The aim of this study was to define the different courses and percentages of hepatic artery that were detected during preoperative evaluation of living liver donors by multidetector computed tomographic angiography (MDCTA). We evaluated 150 donors before hepatic transplantation. All of the donors were evaluated by multislice CT scan with 256 detectors. For each patient, arterial, portal and venous phase images were obtained. The hepatic arterial variations were evaluated by the same radiologist according to Michels' classification. Common hepatic arterial anatomy (type I) was observed in 95 donors (63.3%). Other arterial variations were determined in the remaining 55 donors (36.6%). The second common variation was type XI which did not match with the description of Michels' classification variation in 15 donors (10%). The remaining variations described in Michels' classification were seen at lower rates. Type VII or X variation was not seen. MDCTA is a useful method to identify the blood supply of the liver before the liver transplantations, and surgeons can make their plan on the basis of CT data.
Lee, Sun Hee; Jung, Ji Mi; Song, Min Seob; Choi, Seok jin; Chung, Woo Yeong
2013-08-01
Turner syndrome is well known to be associated with significant cardiovascular abnormalities. This paper studied the incidence of cardiovascular abnormalities in asymptomatic adolescent patients with Turner syndrome using multidetector computed tomography (MDCT) instead of echocardiography. Twenty subjects diagnosed with Turner syndrome who had no cardiac symptoms were included. Blood pressure and electrocardiography (ECG) was checked. Cardiovascular abnormalities were checked by MDCT. According to the ECG results, 11 had a prolonged QTc interval, 5 had a posterior fascicular block, 3 had a ventricular conduction disorder. MDCT revealed vascular abnormalities in 13 patients (65%). Three patients had an aberrant right subclavian artery, 2 had dilatation of left subclavian artery, and others had an aortic root dilatation, aortic diverticulum, and abnormal left vertebral artery. As for venous abnormalities, 3 patients had partial anomalous pulmonary venous return and 2 had a persistent left superior vena cava. This study found cardiovascular abnormalities in 65% of asymptomatic Turner syndrome patients using MDCT. Even though, there are no cardiac symptoms in Turner syndrome patients, a complete evaluation of the heart with echocardiography or MDCT at transition period to adults must be performed.
Pros and cons of colonoscopy in management of acute lower gastrointestinal bleeding
Lhewa, Dekey Y; Strate, Lisa L
2012-01-01
Acute lower gastrointestinal bleeding (LGIB) is a frequent gastrointestinal cause of hospitalization, particularly in the elderly, and its incidence appears to be on the rise. Endoscopic and radiographic measures are available for the evaluation and treatment of LGIB including flexible sigmoidoscopy, colonoscopy, angiography, radionuclide scintigraphy and multi-detector row computed tomography. Although no modality has emerged as the gold standard in the management of LGIB, colonoscopy is the current preferred initial test for the majority of the patients presenting with hematochezia felt to be from a colon source. Colonoscopy has the ability to diagnose all sources of bleeding from the colon and, unlike the radiologic modalities, does not require active bleeding at the time of the examination. In addition, therapeutic interventions such as cautery and endoclips can be applied to achieve hemostasis and prevent recurrent bleeding. Studies suggest that colonoscopy, particularly when performed early in the hospitalization, can decrease hospital length of stay, rebleeding and the need for surgery. However, results from available small trials are conflicting and larger, multicenter studies are needed. Compared to other management options, colonoscopy is a safe procedure with complications reported in less than 2% of patients, including those undergoing urgent examinations. The requirement of bowel preparation (typically 4 or more liters of polyethylene glycol), the logistical complexity of coordinating after-hours colonoscopy, and the low prevalence of stigmata of hemorrhage complicate the use of colonoscopy for LGIB, particularly in urgent situations. This review discusses the above advantages and disadvantages of colonoscopy in the management of acute lower gastrointestinal bleeding in further detail. PMID:22468081
The impact of manual threshold selection in medical additive manufacturing.
van Eijnatten, Maureen; Koivisto, Juha; Karhu, Kalle; Forouzanfar, Tymour; Wolff, Jan
2017-04-01
Medical additive manufacturing requires standard tessellation language (STL) models. Such models are commonly derived from computed tomography (CT) images using thresholding. Threshold selection can be performed manually or automatically. The aim of this study was to assess the impact of manual and default threshold selection on the reliability and accuracy of skull STL models using different CT technologies. One female and one male human cadaver head were imaged using multi-detector row CT, dual-energy CT, and two cone-beam CT scanners. Four medical engineers manually thresholded the bony structures on all CT images. The lowest and highest selected mean threshold values and the default threshold value were used to generate skull STL models. Geometric variations between all manually thresholded STL models were calculated. Furthermore, in order to calculate the accuracy of the manually and default thresholded STL models, all STL models were superimposed on an optical scan of the dry female and male skulls ("gold standard"). The intra- and inter-observer variability of the manual threshold selection was good (intra-class correlation coefficients >0.9). All engineers selected grey values closer to soft tissue to compensate for bone voids. Geometric variations between the manually thresholded STL models were 0.13 mm (multi-detector row CT), 0.59 mm (dual-energy CT), and 0.55 mm (cone-beam CT). All STL models demonstrated inaccuracies ranging from -0.8 to +1.1 mm (multi-detector row CT), -0.7 to +2.0 mm (dual-energy CT), and -2.3 to +4.8 mm (cone-beam CT). This study demonstrates that manual threshold selection results in better STL models than default thresholding. The use of dual-energy CT and cone-beam CT technology in its present form does not deliver reliable or accurate STL models for medical additive manufacturing. New approaches are required that are based on pattern recognition and machine learning algorithms.
Paulus, Elena M; Fabian, Timothy C; Savage, Stephanie A; Zarzaur, Ben L; Botta, Vandana; Dutton, Wesley; Croce, Martin A
2014-02-01
Aggressive screening to diagnose blunt cerebrovascular injury (BCVI) results in early treatment, leading to improved outcomes and reduced stroke rates. While computed tomographic angiography (CTA) has been widely adopted for BCVI screening, evidence of its diagnostic sensitivity is marginal. Previous work from our institution using 32-channel multidetector CTA in 684 patients demonstrated an inadequate sensitivity of 51% (Ann Surg. 2011,253: 444-450). Digital subtraction angiography (DSA) continues to be the reference standard of diagnosis but has significant drawbacks of invasiveness and resource demands. There have been continued advances in CT technology, and this is the first report of an extensive experience with 64-channel multidetector CTA. Patients screened for BCVI using CTA and DSA (reference) at a Level 1 trauma center during the 12-month period ending in May 2012 were identified. Results of CTA and DSA, complications, and strokes were retrospectively reviewed and compared. A total of 594 patients met criteria for BCVI screening and underwent both CTA and DSA. One hundred twenty-eight patients (22% of those screened) had 163 injured vessels: 99 (61%) carotid artery injuries and 64 (39%) vertebral artery injuries. Sixty-four-channel CTA demonstrated an overall sensitivity per vessel of 68% and specificity of 92%. The 52 false-negative findings on CTA were composed of 34 carotid artery injuries and 18 vertebral artery injuries; 32 (62%) were Grade I injuries. Overall, positive predictive value was 36.2%, and negative predictive value was 97.5%. Six procedure-related complications (1%) occurred with DSA, including two iatrogenic dissections and one stroke. Sixty-four-channel CTA demonstrated a significantly improved sensitivity of 68% versus the 51% previously reported for the 32-channel CTA (p = 0.0075). Sixty-two percent of the false-negative findings occurred with low-grade injuries. Considering complications, cost, and resource demand associated with DSA, this study suggests that 64-channel CTA may replace DSA as the primary screening tool for BCVI. Diagnostic study, level III.
Aggarwal, Shivani R; Clavel, Marie-Annick; Messika-Zeitoun, David; Cueff, Caroline; Malouf, Joseph; Araoz, Philip A; Mankad, Rekha; Michelena, Hector; Vahanian, Alec; Enriquez-Sarano, Maurice
2013-01-01
Aortic valve calcification (AVC) is the intrinsic mechanism of valvular obstruction leading to aortic stenosis (AS) and is measurable by multidetector computed tomography. The link between sex and AS is controversial and that with AVC is unknown. We prospectively performed multidetector computed tomography in 665 patients with AS (aortic valve area, 1.05±0.35 cm(2); mean gradient, 39±19 mm Hg) to measure AVC and to assess the impact of sex on the AVC-AS severity link in men and women. AS severity was comparable between women and men (peak aortic jet velocity: 4.05±0.99 versus 3.93±0.91 m/s, P=0.11; aortic valve area index: 0.55±0.20 versus 0.56±0.18 cm(2)/m(2); P=0.46). Conversely, AVC load was lower in women versus men (1703±1321 versus 2694±1628 arbitrary units; P<0.0001) even after adjustment for their smaller body surface area or aortic annular area (both P<0.0001). Thus, odds of high-AVC load were much greater in men than in women (odds ratio, 5.07; P<0.0001). Although AVC showed good associations with hemodynamic AS severity in men and women (all r>0.67; P<0.0001), for any level of AS severity measured by peak aortic jet velocity or aortic valve area index, AVC load, absolute or indexed, was higher in men versus women (all P≤0.01). In this large AS population, women incurred similar AS severity than men for lower AVC loads, even after indexing for their smaller body size. Hence, the relationship between valvular calcification process and AS severity differs in women and men, warranting further pathophysiological inquiry. For AS severity diagnostic purposes, interpretation of AVC load should be different in men and in women.
Khalique, Omar K; Hahn, Rebecca T; Gada, Hemal; Nazif, Tamim M; Vahl, Torsten P; George, Isaac; Kalesan, Bindu; Forster, Molly; Williams, Mathew B; Leon, Martin B; Einstein, Andrew J; Pulerwitz, Todd C; Pearson, Gregory D N; Kodali, Susheel K
2014-08-01
This study sought to determine the impact of quantity and location of aortic valve calcification (AVC) on paravalvular regurgitation (PVR) and rates of post-dilation (PD) immediately after transcatheter aortic valve replacement (TAVR). The impact of AVC in different locations within the aortic valve complex is incompletely understood. This study analyzed 150 patients with severe, symptomatic aortic stenosis who underwent TAVR. Total AVC volume scores were calculated from contrast-enhanced multidetector row computed tomography imaging. AVC was divided by leaflet sector and region (Leaflet, Annulus, left ventricular outflow tract [LVOT]), and a combination of LVOT and Annulus (AnnulusLVOT). Asymmetry was assessed. Receiver-operating characteristic analysis was performed with greater than or equal to mild PVR and PD as classification variables. Logistic regression was performed. Quantity of and asymmetry of AVC for all regions of the aortic valve complex predicted greater than or equal to mild PVR by receiver-operating characteristic analysis (area under the curve = 0.635 to 0.689), except Leaflet asymmetry. Receiver-operating characteristic analysis for PD was significant for quantity and asymmetry of AVC in all regions, with higher area under the curve values than for PVR (area under the curve = 0.648 to 0.741). On multivariable analysis, Leaflet and AnnulusLVOT calcification were independent predictors of both PVR and PD regardless of multidetector row computed tomography area cover index. Quantity and asymmetry of AVC in all regions of the aortic valve complex predict greater than or equal to mild PVR and performance of PD, with the exception of Leaflet asymmetry. Quantity of AnnulusLVOT and Leaflet calcification independently predict PVR and PD when taking into account multidetector row computed tomography area cover index. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Robert-Ebadi, H; Glauser, F; Planquette, B; Moumneh, T; Le Gal, G; Righini, M
2017-08-01
Essentials Safety of computed tomography (CTPA) to exclude pulmonary embolism (PE) in all patients is debated. We analysed the outcome of PE-likely outpatients left untreated after negative CTPA alone. The 3-month venous thromboembolic risk in these patients was very low (0.6%; 95% CI 0.2-2.3). Multidetector CTPA alone safely excludes PE in patients with likely clinical probability. Background In patients with suspected pulmonary embolism (PE) classified as having a likely or high pretest clinical probability, the need to perform additional testing after a negative multidetector computed tomography pulmonary angiography (CTPA) finding remains a matter of debate. Objectives To assess the safety of excluding PE by CTPA without additional imaging in patients with a likely pretest probability of PE. Patients/Methods We retrospectively analyzed patients included in two multicenter management outcome studies that assessed diagnostic algorithms for PE diagnosis. Results Two thousand five hundred and twenty-two outpatients with suspected PE were available for analysis. Of these 2522 patients, 845 had a likely clinical probability as assessed by use of the simplified revised Geneva score. Of all of these patients, 314 had the diagnosis of PE excluded by a negative CTPA finding alone without additional testing, and were left without anticoagulant treatment and followed up for 3 months. Two patients presented with a venous thromboembolism (VTE) during follow-up. Therefore, the 3-month VTE risk in likely-probability patients after a negative CTPA finding alone was 2/314 (0.6%; 95% confidence interval [CI] 0.2-2.3%). Conclusions In outpatients with suspected PE and a likely clinical probability as assessed by use of the simplified revised Geneva score, CTPA alone seems to be able to safely exclude PE, with a low 3-month VTE rate, which is similar to the VTE rate following the gold standard, i.e. pulmonary angiography. © 2017 International Society on Thrombosis and Haemostasis.
Dong, Zhi-Hui; Yang, Zhi-Gang; Chen, Tian-Wu; Chu, Zhi-Gang; Deng, Wen; Shao, Heng
2011-01-01
Massive earthquakes are harmful to humankind. This study of a historical cohort aimed to investigate the difference between earthquake-related crush thoracic traumas and thoracic traumas unrelated to earthquakes using a multi-detector Computed Tomography (CT). We retrospectively compared an earthquake-exposed cohort of 215 thoracic trauma crush victims of the Sichuan earthquake to a cohort of 215 non-earthquake-related thoracic trauma patients, focusing on the lesions and coexisting injuries to the thoracic cage and the pulmonary parenchyma and pleura using a multi-detector CT. The incidence of rib fracture was elevated in the earthquake-exposed cohort (143 vs. 66 patients in the non-earthquake-exposed cohort, Risk Ratio (RR) = 2.2; p<0.001). Among these patients, those with more than 3 fractured ribs (106/143 vs. 41/66 patients, RR=1.2; p<0.05) or flail chest (45/143 vs. 11/66 patients, RR=1.9; p<0.05) were more frequently seen in the earthquake cohort. Earthquake-related crush injuries more frequently resulted in bilateral rib fractures (66/143 vs. 18/66 patients, RR= 1.7; p<0.01). Additionally, the incidence of non-rib fracture was higher in the earthquake cohort (85 vs. 60 patients, RR= 1.4; p<0.01). Pulmonary parenchymal and pleural injuries were more frequently seen in earthquake-related crush injuries (117 vs. 80 patients, RR=1.5 for parenchymal and 146 vs. 74 patients, RR = 2.0 for pleural injuries; p<0.001). Non-rib fractures, pulmonary parenchymal and pleural injuries had significant positive correlation with rib fractures in these two cohorts. Thoracic crush traumas resulting from the earthquake were life threatening with a high incidence of bony thoracic fractures. The ribs were frequently involved in bilateral and severe types of fractures, which were accompanied by non-rib fractures, pulmonary parenchymal and pleural injuries.
Dong, Zhi-hui; Yang, Zhi-gang; Chen, Tian-wu; Chu, Zhi-gang; Deng, Wen; Shao, Heng
2011-01-01
PURPOSE: Massive earthquakes are harmful to humankind. This study of a historical cohort aimed to investigate the difference between earthquake-related crush thoracic traumas and thoracic traumas unrelated to earthquakes using a multi-detector Computed Tomography (CT). METHODS: We retrospectively compared an earthquake-exposed cohort of 215 thoracic trauma crush victims of the Sichuan earthquake to a cohort of 215 non-earthquake-related thoracic trauma patients, focusing on the lesions and coexisting injuries to the thoracic cage and the pulmonary parenchyma and pleura using a multi-detector CT. RESULTS: The incidence of rib fracture was elevated in the earthquake-exposed cohort (143 vs. 66 patients in the non-earthquake-exposed cohort, Risk Ratio (RR) = 2.2; p<0.001). Among these patients, those with more than 3 fractured ribs (106/143 vs. 41/66 patients, RR = 1.2; p<0.05) or flail chest (45/143 vs. 11/66 patients, RR = 1.9; p<0.05) were more frequently seen in the earthquake cohort. Earthquake-related crush injuries more frequently resulted in bilateral rib fractures (66/143 vs. 18/66 patients, RR = 1.7; p<0.01). Additionally, the incidence of non-rib fracture was higher in the earthquake cohort (85 vs. 60 patients, RR = 1.4; p<0.01). Pulmonary parenchymal and pleural injuries were more frequently seen in earthquake-related crush injuries (117 vs. 80 patients, RR = 1.5 for parenchymal and 146 vs. 74 patients, RR = 2.0 for pleural injuries; p<0.001). Non-rib fractures, pulmonary parenchymal and pleural injuries had significant positive correlation with rib fractures in these two cohorts. CONCLUSIONS: Thoracic crush traumas resulting from the earthquake were life threatening with a high incidence of bony thoracic fractures. The ribs were frequently involved in bilateral and severe types of fractures, which were accompanied by non-rib fractures, pulmonary parenchymal and pleural injuries. PMID:21789386
Tung, Matthew K; Cameron, James D; Casan, Joshua M; Crossett, Marcus; Troupis, John M; Meredith, Ian T; Seneviratne, Sujith K
2013-01-01
Minimization of radiation exposure remains an important subject that occurs in parallel with advances in scanner technology. We report our experience of evolving radiation dose and its determinants after the introduction of 320-multidetector row cardiac CT within a single tertiary cardiology referral service. Four cohorts of consecutive patients (total 525 scans), who underwent cardiac CT at defined time points as early as 2008, are described. These include a cohort just after scanner installation, after 2 upgrades of the operating system, and after introduction of an adaptive iterative image reconstruction algorithm. The proportions of nondiagnostic coronary artery segments and studies with nondiagnostic segments were compared between cohorts. Significant reductions were observed in median radiation doses in all cohorts compared with the initial cohort (P < .001). Median dose-length product fell from 944 mGy · cm (interquartile range [IQR], 567.3-1426.5 mGy · cm) to 156 mGy · cm (IQR, 99.2-265.0 mGy · cm). Although the proportion of prospectively triggered scans has increased, reductions in radiation dose have occurred independently of distribution of scan formats. In multiple regression that combined all groups, determinants of dose-length product were tube output, the number of cardiac cycles scanned, tube voltage, scan length, scan format, body mass index, phase width, and heart rate (adjusted R(2) = 0.85, P < .001). The proportion of nondiagnostic coronary artery segments was slightly increased in group 4 (2.9%; P < .01). While maintaining diagnostic quality in 320-multidetector row cardiac CT, the radiation dose has decreased substantially because of a combination of dose-reduction protocols and technical improvements. Continued minimization of radiation dose will increase the potential for cardiac CT to expand as a cardiac imaging modality. Copyright © 2013 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Abernethy malformation with portal vein aneurysm in a child
Chandrashekhara, Sheragaru H.; Bhalla, Ashu Seith; Gupta, Arun Kumar; Vikash, C. S.; Kabra, Susheel Kumar
2011-01-01
Abernethy malformation is an extremely rare anomaly of the splanchnic venous system. We describe multidetector computed tomography findings of an incidentally detected Abernethy malformation with portal vein aneurysm in a two-and-half-year old child. The computed tomography scan was performed for the evaluation of respiratory distress, poor growth, and loss of appetite. PMID:21430844
USDA-ARS?s Scientific Manuscript database
Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row ...
The New Approach to Sport Medicine: 3-D Reconstruction
ERIC Educational Resources Information Center
Ince, Alparslan
2015-01-01
The aim of this study is to present a new approach to sport medicine. Comparative analysis of the Vertebrae Lumbales was done in sedentary group and Muay Thai athletes. It was done by acquiring three dimensional (3-D) data and models through photogrammetric methods from the Multi-detector Computerized Tomography (MDCT) images of the Vertebrae…
MDCT detection of anomalous origins of the left main coronary artery: report of 2 cases.
Matsumoto, Naoya; Sato, Yuichi; Kunimasa, Taeko; Yoda, Shunichi; Yokoyama, Shinichiro; Takayama, Tadateru; Komatsu, Sei; Achenbach, Stephan; Saito, Satoshi; Hirayama, Atsushi
2008-11-28
The left main coronary artery (LMCA) arising either from the right sinus of Valsalva, separately from the right coronary artery (RCA), or from the RCA as a single coronary artery is an extremely rare coronary artery anomaly. We report 2 cases of anomalous origins of the LMCA detected by multidetector-row computed tomography.
Akhilesh, Philomina; Kulkarni, Arti R; Jamhale, Shramika H; Sharma, S D; Kumar, Rajesh; Datta, D
2017-04-25
The purpose of this study was to estimate eye lens dose during brain scans in 16-, 64-, 128- and 256-slice multidetector computed tomography (CT) scanners in helical acquisition mode and to test the feasibility of using radiochromic film as eye lens dosemeter during CT scanning. Eye lens dose measurements were performed using Gafchromic XR-QA2 film on a polystyrene head phantom designed with outer dimensions equivalent to the head size of a reference Indian man. The response accuracy of XR-QA2 film was validated by using thermoluminescence dosemeters. The eye lens dose measured using XR-QA2 film on head phantom for plain brain scanning in helical mode ranged from 43.8 to 45.8 mGy. The XR-QA2 film measured dose values were in agreement with TLD measured dose values within a maximum variation of 8.9%. The good correlation between the two data sets confirms the viability of using XR-QA2 film for eye lens dosimetry. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lacalzada-Almeida, Juan; De la Rosa-Hernández, Alejandro; Izquierdo-Gómez, María Manuela; García-Niebla, Javier; Hernández-Betancor, Iván; Bonilla-Arjona, Juan Alfonso; Barragán-Acea, Antonio; Laynez-Cerdeña, Ignacio
2018-01-01
A 61-year-old male with a prosthetic St Jude aortic valve size 24 presented with heart failure symptoms and minimal-effort angina. Eleven months earlier, the patient had undergone cardiac surgery because of an aortic root dilatation and bicuspid aortic valve with severe regurgitation secondary to infectious endocarditis by Coxiela burnetii and coronary artery disease in the left circumflex coronary artery. Then, a prosthesis valve and a saphenous bypass graft to the left circumflex coronary artery were placed. The patient was admitted to the Cardiology Department of Hospital Universitario de Canarias, Tenerife, Spain and a transthoracic echocardiography was performed that showed severe paraprosthetic aortic regurgitation and an aortic pseudoaneurysm. The 64-slice multidetector computed tomography confirmed the pseudoaneurysm, originating from the right sinus of Valsalva, with a compression of the native right coronary artery and a normal saphenous bypass graft. On the basis of these findings, we performed surgical treatment with a favorable postoperative evolution. In our case, results from complementary cardiac imaging techniques were crucial for patient management. The multidetector computed tomography allowed for a confident diagnosis of an unusual mechanism of coronary ischemia.
Ueda, Tomohiro; Teshima, Hideki; Fukunaga, Shuji; Aoyagi, Shigeaki; Tanaka, Hiroyuki
2013-01-01
This study was performed to evaluate the diagnostic role of electrocardiographically gated multidetector-row computed tomography (MDCT) for prosthetic valve obstruction (PVO) in the aortic position. Between 2002 and 2006, 9 patients were diagnosed with PVO of an aortic bileaflet mechanical valve based on echocardiographic and cineradiographic criteria. These 9 patients were examined using MDCT before replacement of the mechanical valve, and intraoperative findings were compared to morphologic periprosthetic abnormalities observed on MDCT. CT attenuation (Hounsfield units; HU) of the periprosthetic abnormalities was measured to investigate the underlying cause of the PVO. MDCT showed subprosthetic masses extending beyond the prosthetic ring into the orifice of the valve. At reoperation, presence of subprosthetic pannus was confirmed in all of the 9 patients, but no periprosthetic thrombus was found. The mean CT attenuation of the subprosthetic pannus was 170 HU, and it was significantly greater than that obtained from the interventricular septum (108 HU; P<0.0001). MDCT can be used to clearly visualize subprosthetic pannus causing PVO and the mean CT attenuation of subprosthetic pannus is significantly higher than that of the interventricular septum on MDCT.
Greyling, Guilaume; Pasch, Harald
2017-08-25
Multidetector thermal field-flow fractionation (ThFFF) is shown to be a versatile characterisation platform that can be used to characterise hydrophilic polymers in a variety of organic and aqueous solutions with various ionic strengths. It is demonstrated that ThFFF fractionates isotactic and syndiotactic poly(methacrylic acid) (PMAA) as well as poly(2-vinyl pyridine) (P2VP) and poly(4-vinyl pyridine) (P4VP) according to microstructure in organic solvents and that the ionic strength of the mobile phase has no influence on the retention behaviour of the polymers. With regard to aqueous solutions, it is shown that, despite the weak retention, isotactic and syndiotactic PMAA show different retention behaviours which can qualitatively be attributed to microstructure. Additionally, it is shown that the ionic strength of the mobile phase has a significant influence on the thermal diffusion of polyelectrolytes in aqueous solutions and that the addition of an electrolyte is essential to achieve a microstructure-based separation of P2VP and P4VP in aqueous solutions. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kudoh, Kouichi, E-mail: cdk70770@par.odn.ne.jp; Kadota, Masataka; Nakayama, Yoshiharu
2003-09-15
A girl with continuous urinary incontinence was successfully treated by angiographic embolization of a hypoplastic pelvic kidney with a single unilateral vaginal ectopic opening of the ureter. For this intervention, CT angiography was useful for detecting the corresponding renal artery of the hypoplastic kidney.
Imaging of patent foramen ovale with 64-section multidetector CT.
Saremi, Farhood; Channual, Stephanie; Raney, Aidan; Gurudevan, Swaminatha V; Narula, Jagat; Fowler, Steven; Abolhoda, Amir; Milliken, Jeffrey C
2008-11-01
To investigate the feasibility of 64-section multidetector computed tomography (CT) by using CT angiography (a) to demonstrate anatomic detail of the interatrial septum pertinent to the patent foramen ovale (PFO), and (b) to visually detect left-to-right PFO shunts and compare these findings in patients who also underwent transesophageal echocardiography (TEE). In this institutional review board-approved HIPAA-compliant study, electrocardiographically gated coronary CT angiograms in 264 patients (159 men, 105 women; mean age, 60 years) were reviewed for PFO morphologic features. The length and diameter of the opening of the PFO tunnel, presence of atrial septal aneurysm (ASA), and PFO shunts were evaluated. A left-to-right shunt was assigned a grade according to length of contrast agent jet (grade 1,
CT angiography of the renal arteries and veins: normal anatomy and variants.
Hazırolan, Tuncay; Öz, Meryem; Türkbey, Barış; Karaosmanoğlu, Ali Devrim; Oğuz, Berna Sayan; Canyiğit, Murat
2011-03-01
Conventional angiography has long been regarded as gold standard imaging modality for evaluation of the renal vasculature. Introduction of multidetector computed tomography (MDCT) angiography had a groundbreaking impact on evaluation of the renal vessels and is gradually replacing conventional angiography as standard imaging. Herein, we review and illustrate the normal and variant anatomy of renal vessels with special emphasis on imaging protocols and reconstruction techniques in MDCT.
Real-time multiplicity counter
Rowland, Mark S [Alamo, CA; Alvarez, Raymond A [Berkeley, CA
2010-07-13
A neutron multi-detector array feeds pulses in parallel to individual inputs that are tied to individual bits in a digital word. Data is collected by loading a word at the individual bit level in parallel. The word is read at regular intervals, all bits simultaneously, to minimize latency. The electronics then pass the word to a number of storage locations for subsequent processing, thereby removing the front-end problem of pulse pileup.
Multi-detector CT features of acute intestinal ischemia and their prognostic correlations.
Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe
2014-05-28
Acute intestinal ischemia is an abdominal emergency occurring in nearly 1% of patients presenting with acute abdomen. The causes can be occlusive or non occlusive. Early diagnosis is important to improve survival rates. In most cases of late or missed diagnosis, the mortality rate from intestinal infarction is very high, with a reported value ranging from 60% to 90%. Multi-detector computed tomography (MDCT) is a fundamental imaging technique that must be promptly performed in all patients with suspected bowel ischemia. Thanks to the new dedicated reconstruction program, its diagnostic potential is much improved compared to the past and currently it is superior to that of any other noninvasive technique. The increased spatial and temporal resolution, high-quality multi-planar reconstructions, maximum intensity projections, vessel probe, surface-shaded volume rending and tissue transition projections make MDCT the gold standard for the diagnosis of intestinal ischemia, with reported sensitivity, specificity, positive and negative predictive values of 64%-93%, 92%-100%, 90%-100% and 94%-98%, respectively. MDCT contributes to appropriate treatment planning and provides important prognostic information thanks to its ability to define the nature and extent of the disease. The purpose of this review is to examine the diagnostic and prognostic role of MDCT in bowel ischemia with special regard to the state of art new reconstruction software.
Tsili, Athina C; Argyropoulou, Maria I
2015-01-01
Renal cell carcinoma (RCC) accounts for approximately 90%-95% of kidney tumors. With the widespread use of cross-sectional imaging modalities, more than half of RCCs are detected incidentally, often diagnosed at an early stage. This may allow the planning of more conservative treatment strategies. Computed tomography (CT) is considered the examination of choice for the detection and staging of RCC. Multidetector CT (MDCT) with the improvement of spatial resolution and the ability to obtain multiphase imaging, multiplanar and three-dimensional reconstructions in any desired plane brought about further improvement in the evaluation of RCC. Differentiation of RCC from benign renal tumors based on MDCT features is improved. Tumor enhancement characteristics on MDCT have been found closely to correlate with the histologic subtype of RCC, the nuclear grade and the cytogenetic characteristics of clear cell RCC. Important information, including tumor size, localization, and organ involvement, presence and extent of venous thrombus, possible invasion of adjacent organs or lymph nodes, and presence of distant metastases are provided by MDCT examination. The preoperative evaluation of patients with RCC was improved by depicting the presence or absence of renal pseudocapsule and by assessing the possible neoplastic infiltration of the perirenal fat tissue and/or renal sinus fat compartment. PMID:26120380
Zhu, Caisong; Liu, Wei; Yang, Jun; Yang, Jing; Shao, Kangwei; Yuan, Lixin; Chen, Hairong; Lu, Wei; Zhu, Ying
2016-07-01
The aim of the present study was to compare the multidetector computed tomography (MDCT) features of benign and malignant nodules in patients with chronic lymphocytic thyroiditis (CLT). MDCT findings, including the size, solid percentage, calcification, margin, capsule, anteroposterior-transverse diameter ratio as well as the mode and the degree of enhancement of 137 thyroid nodules in 127 CLT cases were retrospectively analyzed. Furthermore, the correlation between MDCT findings and pathological results combined with the CT perfusion imaging was analyzed for the differences between benign and malignant nodules. A total of 77.5% (31/40) of malignant nodules were completely solid, and 33% (32/97) of benign nodules were predominantly cystic. Compared with the benign nodules, micro-calcification and internal calcification were more frequently observed in the malignant nodules (P<0.05). MDCT features such as ill-defined margin, absence of capsule or incomplete capsule or homogeneous enhancement were more likely to be present in the malignant nodules (P<0.05). Nevertheless, no significant difference was observed in the enhancement degree at arterial or venous phase between benign and malignant nodules (P>0.05). MDCT features are useful in differentiating the benign and malignant nodules in CLT patients, and it may be essential for a radiologist to review the MDCT characteristics of nodules in the clinical practice.
Wang, Qiushi; Juan, Yu-Hsiang; Li, Yong; Xie, Jia-Jun; Liu, Hui; Huang, Hongfei; Liu, Zaiyi; Zheng, Junhui; Saboo, Ujwala S.; Saboo, Sachin S.; Liang, Changhong
2015-01-01
Abstract This study aims to evaluate the multidetector computed tomography (CT) imaging features in differentiating exophytic renal angiomyolipoma (AML) from retroperitoneal liposarcoma. We retrospectively enrolled 42 patients with confirmed exophytic renal AML (31 patients) or retroperitoneal liposarcoma (11 patients) during 8 years period to assess: renal parenchymal defect at site of tumor contact, supply from branches of renal artery, tumoral vessel extending through the renal parenchyma, dilated intratumoral vessels, hemorrhage, non–fat-containing intratumoral nodules with postcontrast enhancement, calcification, renal sinus enlargement, anterior displacement of kidneys, and other associated AML. Renal parenchymal defect, renal arterial blood supply, tumoral vessel through the renal parenchyma, dilated intratumoral vessels, intratumoral/perirenal hemorrhage, renal sinus enlargement, and associated AML were seen only or mainly in exophytic renal AML (all P value < 0.05); however, non–fat-attenuating enhancing intratumoral nodules, intratumoral calcification, and anterior displacement of the kidney were more common in liposarcoma (all P value < 0.05). AMLs reveal renal parenchymal defect at the site of tumor contact, supply from renal artery, tumoral vessel extending through the renal parenchyma, dilated intratumoral vessels, intratumoral and/or perirenal hemorrhage, renal sinus enlargement, and associated AML. Non–fat-attenuating enhancing intratumoral nodules, intratumoral calcifications, and anterior displacement of kidney were more commonly seen in liposarcoma. PMID:26376398
Kushnir, Vladimir M; Wani, Sachin B; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris M; Mullady, Daniel K; Jonnalagadda, Sreenivasa S; Early, Dayna S; Edmundowicz, Steven A; Azar, Riad R
2013-04-01
There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: (1) evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP), and multidetector computed tomography (MDCT) for pancreas divisum; and (2) assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent endoscopic retrograde pancreatography and cross-sectional imaging. The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than the sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) (P < 0.001 for each). On review by expert radiologists, the sensitivity of MDCT increased to 83.3% in cases where the pancreatic duct was visualized, with fair IOA (κ = 0.34). Expert review of MRCPs did not identify any additional cases of pancreas divisum; IOA was moderate (κ = 0.43). Endoscopic ultrasound is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum.
Neubauer, Jakob; Benndorf, Matthias; Lang, Hannah; Lampert, Florian; Kemna, Lars; Konstantinidis, Lukas; Neubauer, Claudia; Reising, Kilian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Goerke, Sebastian M
2015-08-01
To compare the visualization of cortical fractures, cortical defects, and orthopedic screws in a dedicated extremity flat-panel computed tomography (FPCT) scanner and a multidetector computed tomography (MDCT) scanner.We used feet of European roe deer as phantoms for cortical fractures, cortical defects, and implanted orthopedic screws. FPCT and MDCT scans were performed with equivalent dose settings. Six observers rated the scans according to number of fragments, size of defects, size of defects opposite orthopedic screws, and the length of different screws. The image quality regarding depiction of the cortical bone was assessed. The gold standard (real number of fragments) was evaluated by autopsy.The correlation of reader assessment of fragments, cortical defects, and screws with the gold standard was similar for FPCT and MDCT. Three readers rated the subjective image quality of the MDCT to be higher, whereas the others showed no preferences.Although the image quality was rated higher in the MDCT than in the FPCT by 3 out of 6 observers, both modalities proved to be comparable regarding the visualization of cortical fractures, cortical defects, and orthopedic screws and of use to musculoskeletal radiology regarding fracture detection and postsurgical evaluation in our experimental setting.
Inci, Ercan; Ekizoglu, Oguzhan; Turkay, Rustu; Aksoy, Sema; Can, Ismail Ozgur; Solmaz, Dilek; Sayin, Ibrahim
2016-10-01
Morphometric analysis of the mandibular ramus (MR) provides highly accurate data to discriminate sex. The objective of this study was to demonstrate the utility and accuracy of MR morphometric analysis for sex identification in a Turkish population.Four hundred fifteen Turkish patients (18-60 y; 201 male and 214 female) who had previously had multidetector computed tomography scans of the cranium were included in the study. Multidetector computed tomography images were obtained using three-dimensional reconstructions and a volume-rendering technique, and 8 linear and 3 angular values were measured. Univariate, bivariate, and multivariate discriminant analyses were performed, and the accuracy rates for determining sex were calculated.Mandibular ramus values produced high accuracy rates of 51% to 95.6%. Upper ramus vertical height had the highest rate at 95.6%, and bivariate analysis showed 89.7% to 98.6% accuracy rates with the highest ratios of mandibular flexure upper border and maximum ramus breadth. Stepwise discrimination analysis gave a 99% accuracy rate for all MR variables.Our study showed that the MR, in particular morphometric measures of the upper part of the ramus, can provide valuable data to determine sex in a Turkish population. The method combines both anthropological and radiologic studies.
Greyling, Guilaume; Pasch, Harald
2018-01-12
Charged block copolymer self-assemblies, such as charged micelles, have attracted much attention as versatile drug delivery systems due to their readily tunable characteristics such as size and surface charge. However, current column-based analytical techniques are not suitable to fractionate and comprehensively characterize charged micelles in terms of size, molar mass, chemical composition and morphology. Multidetector thermal field-flow fractionation (ThFFF) is shown to be a unique characterization platform that can be used to characterize charged micelles in terms of size, molar mass, chemical composition and morphology in aqueous mobile phases with various ionic strengths and pH. This is demonstrated by the characterization of poly(methacrylic acid)-b-poly(methyl methacrylate) self-assemblies in high pH buffers as well as the characterization of cationic poly(2-vinyl pyridine)-b-polystyrene and poly(4-vinyl pyridine)-b-polystyrene self-assemblies in low pH buffers. Moreover, it is shown that ThFFF is capable of separating charged micelles according to the corona composition. These investigations prove convincingly that ThFFF is broadly applicable to the comprehensive characterization of amphiphilic self-assemblies even when aqueous mobile phases are used. Copyright © 2017 Elsevier B.V. All rights reserved.
Greyling, Guilaume; Pasch, Harald
2015-10-02
Poly(methyl methacrylate)-polystyrene (PMMA-PS) micelles with isotactic and syndiotactic coronas are prepared in acetonitrile and subjected to thermal field-flow fractionation (ThFFF) analysis at various conditions of increasing temperature gradients. It is shown for the first time that multidetector ThFFF provides comprehensive information on important micelle characteristics such as size (Dh), shape (Rg/Rh), aggregation number (Z), thermal diffusion (DT) and Soret coefficients (ST) as a function of temperature from a single injection. Moreover, it is found that micelles exhibit a unique decreasing trend in DT as a function of temperature which is independent of the tacticity of the corona and the micelle preparation method used. It is also demonstrated that ThFFF can monitor micelle to vesicle transitions as a function of temperature. In addition to ThFFF, it is found from DLS analysis that the tacticity of the corona influences the critical micelle concentration and the magnitude to which micelles expand/contract with temperature. The tacticity does not, however, influence the critical micelle temperature. Furthermore, the separation of micelles based on the tacticity of the corona highlight the unique capabilities of ThFFF. Copyright © 2015 Elsevier B.V. All rights reserved.
Kulkarni, S; Emre, S; Arvelakis, A; Asch, W; Bia, M; Formica, R; Israel, G
2011-01-01
Multidetector computed tomography (MDCT) angiography is a reliable technique for assessing pre-operative renal anatomy in living kidney donors. The method has largely evolved into protocols that eliminate dedicated venous phase and instead utilize a combined arterial/venous phase to delineate arterial and venous anatomy simultaneously. Despite adoption of this protocol, there has been no study to assess its accuracy. To assess whether or not MDCT angiography compares favorably to intra-operative findings, 102 donors underwent MDCT angiography without a dedicated venous phase with surgical interpretation of renal anatomy. Anatomical variants included multiple arteries (12%), multiple veins (7%), early arterial bifurcation (13%), late venous confluence (5%), circumaortic renal veins (5%), retroaortic vein (1%), and ureteral duplication (2%). The sensitivity and specificity of multiple arterial anomalies were 100% and 97%, respectively. The sensitivity and specificity of multiple venous anomalies were 92% and 98%, respectively. The most common discrepancy was noted exclusively in the interpretation of right venous anatomy as it pertained to the renal vein/vena cava confluence (3%). MDCT angiography using a combined arterial/venous contrast-enhanced phase provides suitable depiction of renal donor anatomy. Careful consideration should be given when planning a right donor nephrectomy whether the radiographic interpretation is suggestive of a late confluence. © 2010 John Wiley & Sons A/S.
Multidetector row computed tomography evaluation of the micropig kidney as a potential renal donor.
Yoon, Woong; Lee, Min Young; Ryu, Jung Min; Moon, Yong Ju; Lee, Sang Hun; Park, Jae Hong; Yun, Seung Pil; Jang, Min Woo; Park, Sung Su; Han, Ho Jae
2010-03-01
Multidetector row computed tomography (MDCT) provides anatomical information about the kidney and other internal organs. Presently, the suitability of 64-channel MDCT to assess the kidney of healthy micropigs was evaluated. Morphological evaluations of the kidney and the major renal vessels of six healthy micropigs were carried out using MDCT, recording kidney volume and the diameter and length of renal arteries and veins. The mean diameters and lengths of the renal artery were 0.44 +/- 0.05 and 4.51 +/- 0.55 cm on the right side and 0.46 +/- 0.06 and 3.36 +/- 0.27 cm on the left side, respectively. The mean diameters and lengths of the renal vein were 1.44 +/- 0.52 and 4.22 +/- 1.29 cm on the right side and 1.38 +/- 0.17 and 5.15 +/- 0.87 cm on the left side, respectively. The mean volume of the right kidney was 79.3 +/- 14.5 mL and of the left kidney was 78.0 +/- 13.9 mL. The data presented in this study suggest that the MDCT offers a noninvasive, rapid, and accurate method for the evaluation of the renal anatomy in living kidney donors. It also provides sufficient information about extra-renal anatomy important for donor surgery and determination of organ suitability.
Light scattering measurement of sodium polyacrylate products
NASA Astrophysics Data System (ADS)
Lama, Nisha; Norwood, David; Boone, Steven; Massie-Boyer, Valerie
2015-03-01
In the presentation, we will describe the use of a multi-detector HPLC incorporating the DAWN EOS multi-angle laser light scattering (MALLS) detector to measure the properties such as molecular weight, RMS radius, contour and persistence length and polydispersity of sodium polyacrylate products. The samples of sodium polyacrylate are used in various industries as thickening agents, coating dispersants, artificial snow, laundry detergent and disposable diapers. Data and results obtained from the experiment will be presented.
Isospin equilibration processes and dipolar signals: Coherent cluster production
NASA Astrophysics Data System (ADS)
Papa, M.; Berceanu, I.; Acosta, L.; Agodi, C.; Auditore, L.; Cardella, G.; Chatterjee, M. B.; Dell'Aquila, D.; De Filippo, E.; Francalanza, L.; Lanzalone, G.; Lombardo, I.; Maiolino, C.; Martorana, N.; Pagano, A.; Pagano, E. V.; Pirrone, S.; Politi, G.; Quattrocchi, L.; Rizzo, F.; Russotto, P.; Trifiró, A.; Trimarchi, M.; Verde, G.; Vigilante, M.
2017-11-01
The total dipolar signal related to multi-break-up processes induced on the system ^{48}Ca +{^{27}Al} at 40MeV/nucleon has been investigated with the CHIMERA multi-detector. Experimental data related to semi-peripheral collisions are shown and compared with CoMD-III calculations. The strong connection between the dipolar signal as obtained from the detected fragments and the dynamics of the isospin equilibration processes is also shortly discussed.
Particle Identification in the NIMROD-ISiS Detector Array
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wuenschel, S.; Hagel, K.; May, L. W.
Interest in the influence of the neutron-to-proton (N/Z) ratio on multifragmenting nuclei has demanded an improvement in the capabilities of multi-detector arrays as well as the companion analysis methods. The particle identification method used in the NIMROD-ISiS 4{pi} array is described. Performance of the detectors and the analysis method are presented for the reaction of {sup 86}Kr+{sup 64}Ni at 35 MeV/u.
Imaging of Combat-Related Thoracic Trauma - Review of Penetrating Trauma.
Lichtenberger, John P; Kim, Andrew M; Fisher, Dane; Tatum, Peter S; Neubauer, Brian; Peterson, P Gabriel; Carter, Brett W
2018-03-01
Combat-related thoracic trauma is a significant contributor to morbidity and mortality of the casualties from Operation Enduring Freedom (OEF) and Operation Iraqi Freedom (OIF). Penetrating, blunt, and blast injuries were the most common mechanisms of trauma. Imaging plays a key role in the management of combat-related thoracic trauma casualties. This review discusses the imaging manifestations of thoracic injuries from penetrating trauma, emphasizing epidemiology and diagnostic clues seen during OEF and OIF. The assessment of radiologic findings in patients who suffer from combat-related thoracic trauma is the basis of this review article. The imaging modalities for this study include multi-detector computed tomography and chest radiography. High-velocity penetrating projectile injuries appear as hemorrhage and re-expansion pulmonary edema from the temporary cavity and a linear, blood-filled track from the permanent cavity. In cases where the projectile passes totally through the body, entrance wounds at the skin surface and tracks through the subcutaneous tissues may be the only indications of penetrating trauma. When assessing vascular injury, special attention should be paid to the right hilum in contrast-enhanced multi-detector computed tomography, as contrast is concentrated in the superior vena cava and superior cavoatrial junction may obscure small fragments. Additionally, CT angiography may show vessel disruption or extravasation of contrast distal to normal vessel location in addition to intraluminal filling defects and pseudo-aneurysms. Tension pneumopericardium may rarely complicate penetrating or blunt chest trauma. On imaging, distension of the pericardial sack by pneumopericardium and compression of the heart support the diagnosis of tension. On multi-detector computed tomography in the acute trauma setting, fluid in the pleural space should be considered hemothorax, particularly when Hounsfield units are above 35. Acutely, extravasated blood will have similar attenuation to the thoracic vasculature, whereas clotted blood will have higher values of 50-90 Hounsfield units. Combat-related thoracic trauma continues to be a significant contributor to the morbidity and mortality of those injured during OEF and OIF. This review of the imaging manifestations of penetrating thoracic injury during OEF and OIF focuses on key diagnostic findings for clinicians caring for combat casualties. The distinct injury pattern and atypical imaging manifestations of penetrating trauma are important to recognize early due to the acuity of this patient population and the influence of accurate diagnosis on clinical management.
Tacher, Vania; Duran, Rafael; Lin, MingDe; Sohn, Jae Ho; Sharma, Karun V.; Wang, Zhijun; Chapiro, Julius; Gacchina Johnson, Carmen; Bhagat, Nikhil; Dreher, Matthew R.; Schäfer, Dirk; Woods, David L.; Lewis, Andrew L.; Tang, Yiqing; Grass, Michael; Wood, Bradford J.
2016-01-01
Purpose To assess the visibility of radiopaque microspheres during transarterial embolization (TAE) in the VX2 rabbit liver tumor model by using multimodality imaging, including single-snapshot radiography, cone-beam computed tomography (CT), multidetector CT, and micro-CT. Materials and Methods The study was approved by the institutional animal care and use committee. Fifteen VX2-tumor-bearing rabbits were assigned to three groups depending on the type of embolic agent injected: 70–150-μm radiopaque microspheres in saline (radiopaque microsphere group), 70–150-μm radiopaque microspheres in contrast material (radiopaque microsphere plus contrast material group), and 70–150-μm radiolucent microspheres in contrast material (nonradiopaque microsphere plus contrast material group). Rabbits were imaged with single-snapshot radiography, cone-beam CT, and multidetector CT. Three to 5 weeks after sacrifice, excised livers were imaged with micro-CT and histologic analysis was performed. The visibility of the embolic agent was assessed with all modalities before and after embolization by using a qualitative three-point scale score reading study and a quantitative assessment of the signal-to-noise ratio (SNR) change in various regions of interest, including the tumor and its feeding arteries. The Kruskal-Wallis test was used to compare the rabbit characteristics across groups, and the Wilcoxon signed rank test was used to compare SNR measurements before and after embolization. Results Radiopaque microspheres were qualitatively visualized within tumor feeding arteries and targeted tissue with all imaging modalities (P < .05), and their presence was confirmed with histologic examination. SNRs of radiopaque microsphere deposition increased after TAE on multidetector CT, cone-beam CT, and micro-CT images (P < .05). Similar results were obtained when contrast material was added to radiopaque microspheres, except for additional image attenuation due to tumor enhancement. For the group with nonradiopaque microspheres and contrast material, retained tumoral contrast remained qualitatively visible with all modalities except for micro-CT, which demonstrated soluble contrast material washout over time. Conclusion Radiopaque microspheres were visible with all imaging modalities and helped increase conspicuity of the tumor as well as its feeding arteries after TAE in a rabbit VX2 liver tumor model. © RSNA, 2015 PMID:26678453
Hagendorfer, Harald; Kaegi, Ralf; Traber, Jacqueline; Mertens, Stijn F L; Scherrers, Roger; Ludwig, Christian; Ulrich, Andrea
2011-11-14
In this work we discuss about the method development, applicability and limitations of an asymmetric flow field flow fractionation (A4F) system in combination with a multi-detector setup consisting of UV/vis, light scattering, and inductively coupled plasma mass spectrometry (ICPMS). The overall aim was to obtain a size dependent-, element specific-, and quantitative method appropriate for the characterization of metallic engineered nanoparticle (ENP) dispersions. Thus, systematic investigations of crucial method parameters were performed by employing well characterized Au nanoparticles (Au-NPs) as a defined model system. For good separation performance, the A4F flow-, membrane-, and carrier conditions were optimized. To obtain reliable size information, the use of laser light scattering based detectors was evaluated, where an online dynamic light scattering (DLS) detector showed good results for the investigated Au-NP up to a size of 80 nm in hydrodynamic diameter. To adapt large sensitivity differences of the various detectors, as well as to guarantee long term stability and minimum contamination of the mass spectrometer a split-flow concept for coupling ICPMS was evaluated. To test for reliable quantification, the ICPMS signal response of ionic Au standards was compared to that of Au-NP. Using proper stabilization with surfactants, no difference for concentrations of 1-50 μg Au L(-1) in the size range from 5 to 80 nm for citrate stabilized dispersions was observed. However, studies using different A4F channel membranes showed unspecific particle-membrane interaction resulting in retention time shifts and unspecific loss of nanoparticles, depending on the Au-NP system as well as membrane batch and type. Thus, reliable quantification and discrimination of ionic and particular species was performed using ICPMS in combination with ultracentrifugation instead of direct quantification with the A4F multi-detector setup. Figures of merit were obtained, by comparing the results from the multi detector approach outlined above, with results from batch-DLS and transmission electron microscopy (TEM). Furthermore, validation performed with certified NIST Au-NP showed excellent agreement. The developed methods show potential for characterization of other commonly used and important metallic engineered nanoparticles. Copyright © 2011 Elsevier B.V. All rights reserved.
Hilar cholangiocarcinoma: Cross sectional evaluation of disease spectrum
Mahajan, Mangal S; Moorthy, Srikanth; Karumathil, Sreekumar P; Rajeshkannan, R; Pothera, Ramchandran
2015-01-01
Although hilar cholangiocarcinoma is relatively rare, it can be diagnosed on imaging by identifying its typical pattern. In most cases, the tumor appears to be centered on the right or left hepatic duct with involvement of the ipsilateral portal vein, atrophy of hepatic lobe on that side, and invasion of adjacent liver parenchyma. Multi-detector computed tomography (MDCT) and magnetic resonance cholangiopancreatography (MRCP) are commonly used imaging modalities to assess the longitudinal and horizontal spread of tumor. PMID:25969643
Update on the imaging diagnosis of otosclerosis.
Gredilla Molinero, J; Mancheño Losa, M; Santamaría Guinea, N; Arévalo Galeano, N; Grande Bárez, M
2016-01-01
Otosclerosis is a primary osteodystrophy of the temporal bone that causes progressive conductive hearing loss. The diagnosis is generally clinical, but multidetector CT (MDCT), the imaging technique of choice, is sometimes necessary. The objective of this article is to systematically review the usefulness of imaging techniques for the diagnosis and postsurgical assessment of otosclerosis, fundamentally the role of MDCT, to decrease the surgical risk. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Interrupted Aortic Arch Associated with Absence of Left Common Carotid Artery: Imaging with MDCT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Onbas, Omer; Olgun, Hasim; Ceviz, Naci
2006-06-15
Interrupted aortic arch (IAA) is a rare severe congenital heart defect defined as complete luminal and anatomic discontinuity between ascending and descending aorta. Although its association with various congenital heart defects has been reported, absence of left common carotid artery (CCA) in patients with IAA has not been reported previously. We report a case of IAA associated with the absence of left CCA which was clearly shown on multidetector-row spiral CT.
Idriz, Sanjin; Patel, Jaymin H; Ameli Renani, Seyed; Allan, Rosemary; Vlahos, Ioannis
2015-01-01
The use of computed tomography (CT) in clinical practice has been increasing rapidly, with the number of CT examinations performed in adults and children rising by 10% per year in England. Because the radiology community strives to reduce the radiation dose associated with pediatric examinations, external factors, including guidelines for pediatric head injury, are raising expectations for use of cranial CT in the pediatric population. Thus, radiologists are increasingly likely to encounter pediatric head CT examinations in daily practice. The variable appearance of cranial sutures at different ages can be confusing for inexperienced readers of radiologic images. The evolution of multidetector CT with thin-section acquisition increases the clarity of some of these sutures, which may be misinterpreted as fractures. Familiarity with the normal anatomy of the pediatric skull, how it changes with age, and normal variants can assist in translating the increased resolution of multidetector CT into more accurate detection of fractures and confident determination of normality, thereby reducing prolonged hospitalization of children with normal developmental structures that have been misinterpreted as fractures. More important, the potential morbidity and mortality related to false-negative interpretation of fractures as normal sutures may be avoided. The authors describe the normal anatomy of all standard pediatric sutures, common variants, and sutural mimics, thereby providing an accurate and safe framework for CT evaluation of skull trauma in pediatric patients. (©)RSNA, 2015.
Hirono, Keiichi; Hata, Yukiko; Miyao, Naruaki; Nakaoka, Hideyuki; Saito, Kazuyoshi; Ibuki, Keijiro; Watanabe, Kazuhiro; Ozawa, Sayaka; Higuma, Tomonori; Yoshimura, Naoki; Nishida, Naoki; Ichida, Fukiko
2016-09-01
Anomalous origin of the right coronary artery (AORCA) is a rare congenital anomaly that may cause myocardial ischemia and sudden death. We reviewed the clinicopathological records of three cases of AORCA, and compared these with two cases of sudden cardiac death with AORCA revealed by autopsy. We report three juvenile cases with an AORCA originating above the commissural junction between the left and right aortic sinuses, with interarterial and intramural compression. They presented with exertional symptoms and were diagnosed with an AORCA by multidetector computed tomography (MDCT), which successfully delineated the spatial resolution of the anomalous origin and course of the right coronary artery (RCA), in the operating room. All three underwent successful surgical unroofing of the RCA. Two cases of sudden cardiac death with AORCA revealed by autopsy showed a slit-like orifice, acute-angled take-off, and long intramural course of the RCA, resembling the RCAs of three juvenile cases. It is crucial to be alert to the presentation of exertional symptoms, as sudden death may be the first manifestation of an anomalous coronary artery, such as those observed in these three cases. MDCT provided an excellent definition and spatial resolution of the unusual origin and intramural course of the RCA, facilitating the correct surgical remedy and resulting in a good outcome for the patients. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Park, Ko Woon; Kim, Seong Hyun; Choi, Seong Ho; Lee, Won Jae
2010-01-01
To evaluate useful computed tomographic features to differentiate nonneoplastic and neoplastic gallbladder polyps 1 cm or bigger. Thirty-one patients with 32 nonneoplastic polyps and 67 patients with 73 neoplastic polyps 1 cm or bigger underwent unenhanced and dual-phase (arterial and portal venous phases) multi-detector row computed tomography. Gallbladder polyps were diagnosed by cholecystectomy. Computed tomographic features including size (
Role of multidetector computed tomography in evaluating incidentally detected breast lesions.
Moschetta, Marco; Scardapane, Arnaldo; Lorusso, Valentina; Rella, Leonarda; Telegrafo, Michele; Serio, Gabriella; Angelelli, Giuseppe; Ianora, Amato Antonio Stabile
2015-01-01
Computed tomography (CT) does not represent the primary method for the evaluation of breast lesions; however, it can detect breast abnormalities, even when performed for other reasons related to thoracic structures. The aim of this study is to evaluate the potential benefits of 320-row multidetector CT (MDCT) in evaluating and differentiating incidentally detected breast lesions by using vessel probe and 3D analysis software with net enhancement value. Sixty-two breast lesions in 46 patients who underwent 320-row chest CT examination were retrospectively evaluated. CT scans were assessed searching for the presence, location, number, morphological features, and density of breast nodules. Net enhancement was calculated by subtracting precontrast density from the density obtained by postcontrast values. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CT were calculated for morphological features and net enhancement. Thirty of 62 lesions were found to be malignant at histological examination and 32 were found to be benign. When morphological features were considered, the sensitivity, specificity, accuracy, PPV, and NPV of CT were 87%, 100%, 88%, 100%, and 50%, respectively. Based on net enhancement, CT reached a sensitivity, specificity, accuracy, PPV, and NPV of 100%, 94%, 97%, 94%, and 100%, respectively. MDCT allows to recognize and characterize breast lesions based on morphological features. Net enhancement can be proposed as an additional accurate feature of CT.
Rocco, Francesco; Cozzi, Luigi Alberto; Cozzi, Gabriele
2015-07-01
To use triphasic multi-detector computed tomography (MDCT) to study the renal segmental arterial anatomy and its relationship with the urinary tract to plan nephron-sparing surgery (NSS). One hundred and fifty nine patients underwent abdominal contrast-enhanced MDCT. We evaluated renal arteries and parenchymal vasculature. In 61 patients, the arteries and the urinary tract were represented simultaneously. 86.60% presented a single renal artery; 13.4%, multiple arteries. All single renal arteries divided into anterior and posterior branch before the hilum. The anterior artery branched into a superior, middle, and inferior branch. In 43.14%, the inferior artery arose before the others; in 45.75%, the superior artery arose before the others; in 9.80%, the branches shared a common trunk. In 26.80%, the posterior artery supplies the entire posterior surface; in 73.20%, it ends along the inferior calyx. In 96.73%, the upper pole was vascularized by the anterior superior branch and the posterior artery: the "tuning fork". MDCT showed four vascular segments in 96.73% and five in 3.27%. MDCT showed two avascular areas: the first along the projection of the inferior calyx on the posterior aspect, the second between the branches of the "tuning fork". The arterial phase provides the arterial tree representation; the delayed phase shows arteries and urinary tract simultaneously. MDCT provides a useful representation of the renal anatomy prior to intervascular-intrarenal NSS.
ZHU, CAISONG; LIU, WEI; YANG, JUN; YANG, JING; SHAO, KANGWEI; YUAN, LIXIN; CHEN, HAIRONG; LU, WEI; ZHU, YING
2016-01-01
The aim of the present study was to compare the multidetector computed tomography (MDCT) features of benign and malignant nodules in patients with chronic lymphocytic thyroiditis (CLT). MDCT findings, including the size, solid percentage, calcification, margin, capsule, anteroposterior-transverse diameter ratio as well as the mode and the degree of enhancement of 137 thyroid nodules in 127 CLT cases were retrospectively analyzed. Furthermore, the correlation between MDCT findings and pathological results combined with the CT perfusion imaging was analyzed for the differences between benign and malignant nodules. A total of 77.5% (31/40) of malignant nodules were completely solid, and 33% (32/97) of benign nodules were predominantly cystic. Compared with the benign nodules, micro-calcification and internal calcification were more frequently observed in the malignant nodules (P<0.05). MDCT features such as ill-defined margin, absence of capsule or incomplete capsule or homogeneous enhancement were more likely to be present in the malignant nodules (P<0.05). Nevertheless, no significant difference was observed in the enhancement degree at arterial or venous phase between benign and malignant nodules (P>0.05). MDCT features are useful in differentiating the benign and malignant nodules in CLT patients, and it may be essential for a radiologist to review the MDCT characteristics of nodules in the clinical practice. PMID:27347131
Ozcan, H Nursun; Gormez, Ayşegul; Ozsurekci, Yasemin; Karakaya, Jale; Oguz, Berna; Unal, Sule; Cetin, Mualla; Ceyhan, Mehmet; Haliloglu, Mithat
2017-02-01
Computed tomography (CT) is commonly used to detect pulmonary infection in immunocompromised children. To compare MRI and multidetector CT findings of pulmonary abnormalities in immunocompromised children. Seventeen neutropaenic children (6 girls; ages 2-18 years) were included. Non-contrast-enhanced CT was performed with a 64-detector CT scanner. Axial and coronal non-enhanced thoracic MRI was performed using a 1.5-T scanner within 24 h of the CT examination (true fast imaging with steady-state free precession, fat-saturated T2-weighted turbo spin echo with motion correction, T2-weighted half-Fourier single-shot turbo spin echo [HASTE], fat-saturated T1-weighted spoiled gradient echo). Pulmonary abnormalities (nodules, consolidations, ground glass opacities, atelectasis, pleural effusion and lymph nodes) were evaluated and compared among MRI sequences and between MRI and CT. The relationship between MRI sequences and nodule sizes was examined by chi- square test. Of 256 CT lesions, 207 (81%, 95% confidence interval [CI] 76-85%) were detected at MRI. Of 202 CT-detected nodules, 157 (78%, 95% CI 71-83%) were seen at motion-corrected MRI. Of the 1-5-mm nodules, 69% were detected by motion-corrected T2-weighted MRI and 38% by HASTE MRI. Sensitivity of MRI (both axial fat-saturated T2-weighted turbo spin echo with variable phase encoding directions (BLADE) images and HASTE sequences) to detect pulmonary abnormalities is promising.
Kushnir, Vladimir M.; Wani, Sachin B.; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris; Mullady, Daniel; Jonnalagadda, Sreenivasa S.; Early, Dayna S.; Edmundowicz, Steven A.; Azar, Riad R.
2014-01-01
OBJECTIVES There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: 1. Evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP) and multi-detector computed tomography (MDCT) for pancreas divisum. 2. Assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. METHODS For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography (ERP) who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent ERP and cross-sectional imaging. RESULTS The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) [p<0.001 for each]. On review by expert radiologists the sensitivity of MDCT increased to 83.3% in cases where the pancreatic duct was visualized, with fair IOA (қ=0.34). Expert review of MRCPs did not identify any additional cases of pancreas divisum; IOA was moderate (қ=0.43). CONCLUSIONS EUS is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum. PMID:23211370
Mejean, Simon; Bouvier, Erik; Bataille, Vincent; Seknadji, Patrick; Fourchy, Dominique; Tabet, Jean-Yves; Lairez, Olivier; Cormier, Bertrand
2016-10-15
Mitral annular calcium (MAC) is a common finding in older patients referred for transcatheter aortic valve implantation (TAVI). Multidetector computed tomography (MDCT) allows fine quantification of the calcific deposits. Our objective was to estimate the prevalence of MAC and associated mitral stenosis (MS) in patients referred for TAVI using MDCT. A cohort of 346 consecutive patients referred for TAVI evaluation was screened by MDCT for MAC: 174 had MAC (50%). Of these patients, 165 patients (95%) had mitral valve area (MVA) assessable by MDCT planimetry (age 83.8 ± 5.9 years). Median mitral calcium volume and MVA were 545 mm 3 (193 to 1,253 mm 3 ) and 234 mm 2 (187 to 297 mm 2 ), respectively. The MS was very severe, severe, and moderate in 2%, 22%, and 10% patients, respectively. By multivariate analysis, MVA was independently correlated to mitral calcium volume, aortic annular area, and some specific patterns of mitral leaflet calcium. Based on these findings, a formula was elaborated to predict the presence of a significant MS. In conclusion, MDCT allows detailed assessment of MAC in TAVI populations, demonstrating a high prevalence. Mitral analysis should become routine during MDCT screening before TAVI as it may alter therapeutic strategy. Copyright © 2016 Elsevier Inc. All rights reserved.
Ogura, I; Kaneda, T; Sasaki, Y; Buch, K; Sakai, O
2015-06-01
Temporal bone fracture after mandibular trauma is thought to be rare, and its prevalence has not been reported in the literature. The purpose of this study was to investigate the prevalence of temporal bone fractures in patients with mandibular fractures and the relationship between temporal bone fractures and the mandibular fracture location using multidetector-row computed tomography (MDCT). A prospective study was performed in 201 patients with mandibular fractures who underwent 64-MDCT scans. The mandibular fracture locations were classified as median, paramedian, angle, and condylar types. Statistical analysis for the relationship between prevalence of temporal bone fractures and mandibular fracture locations was performed using χ(2) test with Fisher's exact test. A P-value < 0.05 was considered statistically significant. The percentage of cases with temporal bone fracture was 3.0 % of all patients with mandibular fractures and 19.0 % of those with multiple mandibular fractures of paramedian and condylar type. There was a significant relationship between the incidence of temporal bone fracture and the paramedian- and condylar-type mandibular fracture (P = 0.001). Multiple mandibular fractures of paramedian and condylar type may be a stronger indicator for temporal bone fractures. This study suggests that patients with mandibular fracture, especially the paramedian and condylar type, should be examined for coexisting temporal bone fracture using MDCT.
Foster, Allison; Morandi, Federica; May, Elizabeth
2015-01-01
Previous reports describing the prevalence of ear diseases in dogs have primarily been based on dogs presenting with clinical signs of disease. The prevalence of subclinical ear disease remains unknown. The purpose of this cross-sectional retrospective study was to describe the prevalence of lesions consistent with middle and external ear disease in dogs presented for multidetector computed tomography (CT) of the head and/or cranial cervical spine at our hospital during the period of July 2011 and August 2013. For each included dog, data recorded were signalment, CT findings, diagnosis, and treatment. A total of 199 dogs met inclusion criteria. Nineteen dogs (9.5%) were referred for evaluation of suspected ear disease and 27 dogs (13.5%) had histories or physical examination findings consistent with otitis externa. A total of 163 dogs (81.9%) had CT lesions consistent with external ear disease (i.e. ear canal mineralization, external canal thickening, and/or narrowing of the external canal). Thirty-nine dogs (19.5%) had CT lesions consistent with middle ear disease (i.e. soft tissue attenuating/fluid material in the tympanic bullae, bulla wall thickening or lysis, and/or periosteal proliferation of the temporal bone). Findings from this study indicated that the prevalence of external and middle ear disease in dogs could be higher than that previously reported. © 2014 American College of Veterinary Radiology.
Torimitsu, Suguru; Makino, Yohsuke; Saitoh, Hisako; Sakuma, Ayaka; Ishii, Namiko; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Yamaguchi, Rutsuko; Hashimoto, Mari; Hoshioka, Yumi; Iwase, Hirotaro
2015-12-01
Sex estimation of decomposed or skeletal remains is clearly important in forensic contexts. Recently, contemporary population-specific data has been obtained using multidetector computed tomography (MDCT) scanning. The main purpose of this study was to investigate skeletal pelvic dimorphism in a contemporary Japanese forensic sample and to quantify the accuracy of sex estimation using various pelvic measurements obtained from three-dimensional (3D) CT images. This study used a total of 208 cadavers (104 males, 104 females) of which postmortem CT scanning and subsequent forensic autopsy were conducted between December 2011 and August 2014. Eleven measurements of each pelvis were obtained from 3D CT reconstructed images that extracted only bone data. The measurements were analyzed using descriptive statistics and discriminant function analyses. All except one measurement were dimorphic in terms of sex differences. Univariate discriminant function analyses using these measurements provided sex classification accuracy rates of 62.0-98.1%. The subpubic angle was found to contribute most significantly to accurate sex estimation. Multivariate discriminant functions yielded sex prediction accuracy rates of 63.9-98.1%. In conclusion, the pelvic measurements obtained from 3D CT images of a contemporary Japanese population successfully demonstrated sexual dimorphism and may be useful for the estimation of skeletal sex in the field of forensic anthropology. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Toyota, Naoyuki; Nakamura, Yuko; Hieda, Masashi; Akiyama, Naoko; Terada, Hiroaki; Matsuura, Noriaki; Nishiki, Masayo; Kono, Hirotaka; Kohno, Hiroshi; Irei, Toshimitsu; Yoshikawa, Yukinobu; Kuraoka, Kazuya; Taniyama, Kiyomi; Awai, Kazuo
2013-09-01
The purpose of this study was to evaluate the diagnostic capability of gadoxetate disodium (Gd-EOB)-MRI for the detection of hepatocellular carcinoma (HCC) compared with multidetector CT (MDCT). Fifty patients with 57 surgically proven HCCs who underwent Gd-EOB-MRI and MDCT from March 2008 to June 2011 were evaluated. Two observers evaluated MR and CT on a lesion-by-lesion basis. We analyzed sensitivity by grading on a 5-point scale, the degree of arterial enhancement and the differences in histological grades in the diffusion-weighted images (DWI). The results showed that the sensitivity of Gd-EOB-MRI was higher than that of MDCT especially for HCCs that were 1 cm in diameter or smaller. The hepatobiliary phase was useful for the detecting of small HCC. We had few cases in which it was difficult to judge HCC in the arterial enhancement between MRI and MDCT. In the diffusion-weighted image, well differentiated HCC tended to show a low signal intensity, and poorly differentiated HCC tended to show a high signal intensity. In moderately differentiated HCC's, the mean diameter of the high signal intensity group was larger than that of the low signal intensity group (24.5 mm vs. 15.8 mm). In conclusion, Gd-EOB-MRI tended to show higher sensitivity compared to MDCT in the detection of HCC.
Artioli, Diana; Tagliabue, Marianna; Aseni, Paolo; Sironi, Sandro; Vanzulli, Angelo
2010-11-01
To evaluate the performance of magnetic resonance (MR) and multidetector computed tomography (MDCT) in the assessment of living donor's vascular and biliary anatomy, having surgical findings as reference standard. Thirty-two living liver donors underwent MR cholangiography (1.5-T; standard cholangiography pulse sequences and delayed acquisitions after administration of biliary contrast agent) for biliary anatomy evaluation. MDCT (16-row multidetector scanner, multiphase protocol, 3mm slice thickness) was also performed in all cases for the assessment of vascular anatomy before transplantation. Hepatic veins (<4mm in diameter) were not considered. MR and MDCT images interpretation was performed by two reviewers by consensus, based on source axial images, multiplanar reformats, and three-dimensional (3D) postprocessing images. Surgical intraoperative findings were used as standard of reference. At surgery, 17 biliary anomalies, 3 portal anomalies, 32 venous and 8 arterial variants were found in the 32 patients. MR correctly identified 15/17 biliary anomalies, with a sensitivity of 88% and a specificity of 93%. MDCT correctly identified 8/8 arterial, 3/3 portal and 29/32 venous variants, with a sensitivity of 100% and 91%, respectively, and a specificity of 100%. MR and MDCT proved to be efficient in evaluating living liver donor's biliary and vascular anatomy. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Antunes, Sofia; Esposito, Antonio; Palmisano, Anna; Colantoni, Caterina; Cerutti, Sergio; Rizzo, Giovanna
2016-05-01
Extraction of the cardiac surfaces of interest from multi-detector computed tomographic (MDCT) data is a pre-requisite step for cardiac analysis, as well as for image guidance procedures. Most of the existing methods need manual corrections, which is time-consuming. We present a fully automatic segmentation technique for the extraction of the right ventricle, left ventricular endocardium and epicardium from MDCT images. The method consists in a 3D level set surface evolution approach coupled to a new stopping function based on a multiscale directional second derivative Gaussian filter, which is able to stop propagation precisely on the real boundary of the structures of interest. We validated the segmentation method on 18 MDCT volumes from healthy and pathologic subjects using manual segmentation performed by a team of expert radiologists as gold standard. Segmentation errors were assessed for each structure resulting in a surface-to-surface mean error below 0.5 mm and a percentage of surface distance with errors less than 1 mm above 80%. Moreover, in comparison to other segmentation approaches, already proposed in previous work, our method presented an improved accuracy (with surface distance errors less than 1 mm increased of 8-20% for all structures). The obtained results suggest that our approach is accurate and effective for the segmentation of ventricular cavities and myocardium from MDCT images.
Jinzaki, Masahiro; Okabe, Teruo; Endo, Ayaka; Kawamura, Akio; Koga, Seiko; Yamada, Minoru; Fukuda, Keiichi; Kuribayashi, Sachio
2012-01-01
To clarify multidetector computed tomography (MDCT) findings of attenuated plaque detected by intravascular ultrasound (IVUS). One hundred and fifty-four patients with stable angina underwent MDCT before IVUS. The attenuated plaque was identified in the targeted artery with IVUS, and the same artery was analyzed with MDCT for the presence of a high density area (HDA) >130 Hounsfield units (HU), and a low density area (LDA) <30 HU. A HDA in attenuated plaque was compared with that in calcified plaque. Ten attenuated plaques and 15 calcified plaques were identified in 9 of 154 patients (males=9, 66.2 ± 9.5 years). Eight of the 10 attenuated plaques and all 15 calcified plaques were accompanied with a HDA on MDCT. The HDA ranged from 174 to 667 HU (mean 389.0 ± 148.3 HU) in the 8 attenuated plaques, and from 545 to 1,205 HU (mean 920.9 ± 215.9 HU) in 15 calcified plaques. There was a significant difference in CT density of the HDA between the attenuated and calcified plaque (P<0.001). All attenuated plaques contained LDA <30 HU in the portions without HDA. MDCT has the ability to demonstrate attenuated plaque as the combination of HDA (approximately 400 HU on average) and LDA <30 HU. The HDA can be differentiated from calcified plaque by its lower CT density value.
Tonolini, Massimo; Ierardi, Anna Maria; Bracchi, Elena; Magistrelli, Paolo; Vella, Adriana; Carrafiello, Gianpaolo
2017-10-01
Despite availability of effective therapies, peptic ulcer disease (PUD) remains a major global disease, resulting from a combination of persistent Helicobacter pylori infection and widespread use of nonsteroidal anti-inflammatory drugs. Albeit endoscopy definitely represents the mainstay diagnostic technique, patients presenting to emergency departments with unexplained abdominal pain generally undergo multidetector CT as an initial investigation. Although superficial ulcers generally remain inconspicuous, careful multiplanar CT interpretation may allow to detect deep ulcers, secondary mural and extraluminal signs of peptic gastroduodenitis, thereby allowing timely endoscopic verification and appropriate treatment. This pictorial essay aims to provide radiologists with an increased familiarity with CT diagnosis of non-perforated PUD, with emphasis on differential diagnosis. Following an overview of current disease epidemiology and complications, it explains the appropriate CT acquisition and interpretation techniques, and reviews with several examples the cross-sectional findings of uncomplicated PUD. Afterwards, the CT features of PUD complications such as ulcer haemorrhage, gastric outlet obstruction, biliary and pancreatic fistulisation are presented. • Gastric and duodenal peptic ulcers are increasingly caused by nonsteroidal anti-inflammatory drugs • Multiplanar CT interpretation allows detecting deep ulcers and secondary signs of gastroduodenitis • CT diagnosis of uncomplicated peptic disease relies on direct and indirect signs • Currently the commonest complication, haemorrhage may be treated with transarterial embolisation • Other uncommon complications include gastric outlet obstruction and biliopancreatic fistulisation.
Hirose, Tomoaki; Igami, Tsuyoshi; Koga, Kusuto; Hayashi, Yuichiro; Ebata, Tomoki; Yokoyama, Yukihiro; Sugawara, Gen; Mizuno, Takashi; Yamaguchi, Junpei; Mori, Kensaku; Nagino, Masato
2017-03-01
Fusion angiography using reconstructed multidetector-row computed tomography (MDCT) images, and cholangiography using reconstructed images from MDCT with a cholangiographic agent include an anatomical gap due to the different periods of MDCT scanning. To conquer such gaps, we attempted to develop a cholangiography procedure that automatically reconstructs a cholangiogram from portal-phase MDCT images. The automatically produced cholangiography procedure utilized an original software program that was developed by the Graduate School of Information Science, Nagoya University. This program structured 5 candidate biliary tracts, and automatically selected one as the candidate for cholangiography. The clinical value of the automatically produced cholangiography procedure was estimated based on a comparison with manually produced cholangiography. Automatically produced cholangiograms were reconstructed for 20 patients who underwent MDCT scanning before biliary drainage for distal biliary obstruction. The procedure showed the ability to extract the 5 main biliary branches and the 21 subsegmental biliary branches in 55 and 25 % of the cases, respectively. The extent of aberrant connections and aberrant extractions outside the biliary tract was acceptable. Among all of the cholangiograms, 5 were clinically applied with no correction, 8 were applied with modest improvements, and 3 produced a correct cholangiography before automatic selection. Although our procedure requires further improvement based on the analysis of additional patient data, it may represent an alternative to direct cholangiography in the future.
Machida, Haruhiko; Yuhara, Toshiyuki; Tamura, Mieko; Numano, Tomokazu; Abe, Shinji; Sabol, John M; Suzuki, Shigeru; Ueno, Eiko
2012-06-01
Using an anthropomorphic phantom, we have investigated the feasibility of digital tomosynthesis (DT) of flat-panel detector (FPD) radiography to reduce radiation dose for sinonasal examination compared to multi-detector computed tomography (MDCT). A female Rando phantom was scanned covering frontal to maxillary sinus using the clinically routine protocol by both 64-detector CT (120 kV, 200 mAs, and 1.375-pitch) and DT radiography (80 kV, 1.0 mAs per projection, 60 projections, 40° sweep, and posterior-anterior projections). Glass dosimeters were used to measure the radiation dose to internal organs including the thyroid gland, brain, submandibular gland, and the surface dose at various sites including the eyes during those scans. We compared the radiation dose to those anatomies between both modalities. In DT radiography, the doses of the thyroid gland, brain, submandibular gland, skin, and eyes were 230 ± 90 μGy, 1770 ± 560 μGy, 1400 ± 80 μGy, 1160 ± 2100 μGy, and 112 ± 6 μGy, respectively. These doses were reduced to approximately 1/5, 1/8, 1/12, 1/17, and 1/290 of the respective MDCT dose. For sinonasal examinations, DT radiography enables dramatic reduction in radiation exposure and dose to the head and neck region, particularly to the lens of the eye. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Automated Quantification of Pneumothorax in CT
Do, Synho; Salvaggio, Kristen; Gupta, Supriya; Kalra, Mannudeep; Ali, Nabeel U.; Pien, Homer
2012-01-01
An automated, computer-aided diagnosis (CAD) algorithm for the quantification of pneumothoraces from Multidetector Computed Tomography (MDCT) images has been developed. Algorithm performance was evaluated through comparison to manual segmentation by expert radiologists. A combination of two-dimensional and three-dimensional processing techniques was incorporated to reduce required processing time by two-thirds (as compared to similar techniques). Volumetric measurements on relative pneumothorax size were obtained and the overall performance of the automated method shows an average error of just below 1%. PMID:23082091
Techniques for Targeted Fermi-GBM Follow-Up of Gravitational-Wave Events
NASA Technical Reports Server (NTRS)
Blackburn, L.; Camp, J.; Briggs, M. S.; Connaughton, V.; Jenke, P.; Christensen, N.; Veitch, J.
2012-01-01
The Advanced LIGO and Advanced Virgo ground-based gravitational-wave (GW) detectors are projected to come online 2015 2016, reaching a final sensitivity sufficient to observe dozens of binary neutron star mergers per year by 2018. We present a fully-automated, targeted search strategy for prompt gamma-ray counterparts in offline Fermi-GBM data. The multi-detector method makes use of a detailed model response of the instrument, and benefits from time and sky location information derived from the gravitational-wave signal.
SIKA—the multiplexing cold-neutron triple-axis spectrometer at ANSTO
NASA Astrophysics Data System (ADS)
Wu, C.-M.; Deng, G.; Gardner, J. S.; Vorderwisch, P.; Li, W.-H.; Yano, S.; Peng, J.-C.; Imamovic, E.
2016-10-01
SIKA is a new cold-neutron triple-axis spectrometer receiving neutrons from the cold source CG4 of the 20MW Open Pool Australian Light-water reactor. As a state-of-the-art triple-axis spectrometer, SIKA is equipped with a large double-focusing pyrolytic graphite monochromator, a multiblade pyrolytic graphite analyser and a multi-detector system. In this paper, we present the design, functions, and capabilities of SIKA, and discuss commissioning experimental results from powder and single-crystal samples to demonstrate its performance.
Gupta, Rajiv; Jones, Stephen E; Mooyaart, Eline A Q; Pomerantz, Stuart R
2006-06-01
The development of multidetector row computed tomography (MDCT) now permits visualization of the entire vascular tree that is relevant for the management of stroke within 15 seconds. Advances in MDCT have brought computed tomography angiography (CTA) to the frontline in evaluation of stroke. CTA is a rapid and noninvasive modality for evaluating the neurovasculature. This article describes the role of CTA in the management of stroke. Fundamentals of contrast delivery, common pathologic findings, artifacts, and pitfalls in CTA interpretation are discussed.
The Air-Shower Experiment KASCADE-Grande
NASA Astrophysics Data System (ADS)
Haungs, A.; Apel, W. D.; Arteaga, J. C.; Badea, F.; Bekk, K.; Bertaina, M.; Blümer, J.; Bozdog, H.; Brancus, I. M.; Brüggemann, M.; Buchholz, P.; Cantoni, E.; Chiavassa, A.; Cossavella, F.; Daumiller, K.; de Souza, V.; di Pierro, F.; Doll, P.; Engel, R.; Engler, J.; Finger, M.; Fuhrmann, D.; Ghia, P. L.; Gils, H. J.; Glasstetter, R.; Grupen, C.; Heck, D.; Hörandel, J. R.; Huege, T.; Isar, P. G.; Kampert, K.-H.; Kang, D.; Kickelbick, D.; Klages, H. O.; Kolotaev, Y.; Łuczak, P.; Mathes, H. J.; Mayer, H. J.; Milke, J.; Mitrica, B.; Morello, C.; Navarra, G.; Nehls, S.; Oehlschläger, J.; Ostapchenko, S.; Over, S.; Petcu, M.; Pierog, T.; Rebel, H.; Roth, M.; Schieler, H.; Schröder, F.; Sima, O.; Stümpert, M.; Toma, G.; Trinchero, G.; Ulrich, H.; Walkowiak, W.; Weindl, A.; Wochele, J.; Wommer, M.; Zabierowski, J.; KASCADE-Grande Collaboration
2009-12-01
KASCADE-Grande is an extensive air shower experiment at the Forschungszentrum Karlsruhe, Germany. Main parts of the experiment are the Grande array spread over an area of 700×700 m, the original KASCADE array covering 200×200 m with unshielded and shielded detectors, and additional muon tracking devices. This multi-detector system allows to investigate the energy spectrum, composition, and anisotropies of cosmic rays in the energy range up to 1 EeV. An overview on the performance of the apparatus and first results will be given.
Osteochondral lesions about the ankle.
Naran, Ketan N; Zoga, Adam C
2008-11-01
Osteochondral lesions (OCLs) about the foot and ankle often manifest clinically as prolonged joint pain after trauma, often an ankle sprain, which is refractory to conventional, conservative therapeutic treatment. Noncontrast MR imaging is the standard of care imaging modality for diagnosing and classifying osteochondral lesions, but equivocal or difficult lesions can be assessed more specifically with direct MR arthrography or in conjunction with multidetector CT. Once an OCL has been identified, the imager should make every effort to determine whether it is stable or potentially unstable.
Polyarteritis nodosa: MDCT as a 'One-Stop Shop' Modality for Whole-Body Arterial Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsai, W.-L.; Tsai, I-C.; Lee Tain, E-mail: s841082@ym.edu.t
Polyarteritis nodosa is a rare disease, which is characterized by aneurysm formation and occlusion in the arteries of multiple systems. Due to its extensive involvement, whole-body evaluation is necessary for diagnosis and treatment monitoring. We report a case of polyarteritis nodosa using multidetector-row computed tomography (MDCT) as a 'one-stop shop' modality for whole-body arterial evaluation. With precise protocol design, MDCT can be used as a reliable noninvasive modality providing comprehensive whole-body arterial evaluation.
Wielpütz, Mark O; Heußel, Claus P; Herth, Felix J F; Kauczor, Hans-Ulrich
2014-03-14
Chest X-ray, computed tomography (CT), and magnetic resonance imaging (MRI) each have characteristic advantages and disadvantages that need to be considered in clinical decision-making. This point is discussed in reference to the main types of lung disease that are encountered in practice. A selective literature search was performed in the PubMed and Google Scholar databases. Existing clinical guidelines on the main types of lung disease and studies concerning radiological diagnosis were also con - sidered in this review. There have been no more than a few large-scale, controlled comparative trials of different radiological techniques. Chest X-ray provides general orientation as an initial diagnostic study and is especially useful in the diagnosis of pneumonia, cancer, and chronic obstructive pulmonary disease (COPD). Multi-detector CT affords nearly isotropic spatial resolution at a radiation dose of only 0.2-5 mSv, much lower than before. Its main indications, according to current guidelines, are tumors, acute pulmonary embolism, pulmonary hypertension, pulmonary fibrosis, advanced COPD, and pneumonia in a high-risk patient. MRI is used in the diagnosis of cystic fibrosis, pulmonary embolism, pulmonary hypertension, and bronchial carcinoma. The positive predictive value (PPV) of a chest X-ray in outpatients with pneumonia is only 27% (gold standard, CT); in contrast, an initial, non-randomized trial of MRI in nosocomial pneumonia revealed a PPV of 95%. For the staging of mediastinal lymph nodes in bronchial carcinoma, MRI has a PPV of 88% and positron emission tomography with CT (PET/CT) has a PPV of 79%, while CT alone has a PPV of 41% (gold standard, histology). The choice of radiologicalal technique for the detection, staging, follow-up, and quantification of lung disease should be based on the individual clinical options, so that appropriate treatment can be provided without excessive use of diagnostic testing.
Dodd, Lori E; Wagner, Robert F; Armato, Samuel G; McNitt-Gray, Michael F; Beiden, Sergey; Chan, Heang-Ping; Gur, David; McLennan, Geoffrey; Metz, Charles E; Petrick, Nicholas; Sahiner, Berkman; Sayre, Jim
2004-04-01
Cancer of the lung and bronchus is the leading fatal malignancy in the United States. Five-year survival is low, but treatment of early stage disease considerably improves chances of survival. Advances in multidetector-row computed tomography technology provide detection of smaller lung nodules and offer a potentially effective screening tool. The large number of images per exam, however, requires considerable radiologist time for interpretation and is an impediment to clinical throughput. Thus, computer-aided diagnosis (CAD) methods are needed to assist radiologists with their decision making. To promote the development of CAD methods, the National Cancer Institute formed the Lung Image Database Consortium (LIDC). The LIDC is charged with developing the consensus and standards necessary to create an image database of multidetector-row computed tomography lung images as a resource for CAD researchers. To develop such a prospective database, its potential uses must be anticipated. The ultimate applications will influence the information that must be included along with the images, the relevant measures of algorithm performance, and the number of required images. In this article we outline assessment methodologies and statistical issues as they relate to several potential uses of the LIDC database. We review methods for performance assessment and discuss issues of defining "truth" as well as the complications that arise when truth information is not available. We also discuss issues about sizing and populating a database.
Atar, Eli; Kornowski, Ran; Fuchs, Shmuell; Naftali, Noa; Belenky, Alexander; Bachar, Gil N
2007-10-01
Myocardial bridging is a congenital condition in which a segment of an epicardial artery has an intramural course within the myocardium. The aim of the present study was to evaluate the prevalence of myocardial bridging and the ability of 64-slice coronary computed tomography angiography to identify myocardial bridging in asymptomatic adults. One hundred sixty-nine consecutive asymptomatic subjects underwent 64-row multidetector computed tomography (MDCT) of the coronary arteries. Two experienced CT radiologists identified myocardial bridging >1 mm in thickness, by consensus. We examined the frequency of myocardial bridging and evaluated the length, thickness, and coronary wall lesions. Myocardial bridges were found in 28 (17%) of 165 subjects. Twenty-one subjects (75%) had 1 bridge and 7 subjects (25%) had 2, for a total of 35 myocardial bridges. Twenty-one bridges (60%) were located in the left anterior descending, 8.5% in the diagonal branch, and 2.8% in the circumflex arteries. The segment beneath the myocardial bridge was always free of coronary wall plaques, but the arterial segment proximal to it had significant coronary wall plaques in 24 cases (68.6%). We found that the incidence of myocardial bridging in asymptomatic adults is 7%, which is in agreement with some pathologic studies in the literature. Our study shows that MDCT of the coronary arteries is a reliable and noninvasive technique, which can accurately locate the site of myocardial bridging, and measure its thickness, course, and length.
de Freitas, Ricardo Miguel Costa; Andrade, Celi Santos; Caldas, José Guilherme Mendes Pereira; Kanas, Alexandre Fligelman; Cabral, Richard Halti; Tsunemi, Miriam Harumi; Rodríguez, Hernán Joel Cervantes; Rabbani, Said Rahnamaye
2015-05-01
New spinal interventions or implants have been tested on ex vivo or in vivo porcine spines, as they are readily available and have been accepted as a comparable model to human cadaver spines. Imaging-guided interventional procedures of the spine are mostly based on fluoroscopy or, still, on multidetector computed tomography (MDCT). Cone-beam computed tomography (CBCT) and magnetic resonance imaging (MRI) are also available methods to guide interventional procedures. Although some MDCT data from porcine spines are available in the literature, validation of the measurements on CBCT and MRI is lacking. To describe and compare the anatomical measurements accomplished with MDCT, CBCT, and MRI of lumbar porcine spines to determine if CBCT and MRI are also useful methods for experimental studies. An experimental descriptive-comparative study. Sixteen anatomical measurements of an individual vertebra from six lumbar porcine spines (n=36 vertebrae) were compared with their MDCT, CBCT, and MRI equivalents. Comparisons were made for the absolute values of the parameters. Similarities were found in all imaging methods. Significant correlation (p<.05) was observed with all variables except those that included cartilaginous tissue from the end plates when the anatomical study was compared with the imaging methods. The CBCT and MRI provided imaging measurements of the lumbar porcine spines that were similar to the anatomical and MDCT data, and they can be useful for specific experimental research studies. Copyright © 2015 Elsevier Inc. All rights reserved.
Alasnag, Mirvat; Umakanthan, Branavan; Foster, Gary P
2008-07-01
Coronary arteriography (CA) is the standard method to image coronary lesions. Multidetector cardiac computerized tomography (MDCT) provides high-resolution images of coronary arteries, allowing a noninvasive alternative to determine lesion type. To date, no studies have assessed the ability of MDCT to categorize coronary lesion types. The objective of this study was to determine the accuracy of lesion type categorization by MDCT using CA as a reference standard. Patients who underwent both MDCT and CA within 2 months of each other were enrolled. MDCT and CA images were reviewed in a blinded fashion. Lesions were categorized according to the SCAI classification system (Types I-IV). The origin, proximal and middle segments of the major arteries were analyzed. Each segment comprised a data point for comparison. Analysis was performed using the Spearman Correlation Test. Four hundred eleven segments were studied, of which 110 had lesions. The lesion distribution was as follows: 35 left anterior descending (LAD), 29 circumflex (Cx), 31 right coronary artery (RCA), 2 ramus intermedius, 8 diagonal, 4 obtuse marginal and 2 left internal mammary arteries. Correlations between MDCT and CA were significant in all major vessels (LAD, Cx, RCA) (p < 0.001). The overall correlation coefficient was 0.67. Concordance was strong for lesion Types II-IV (97%) and poor for Type I (30%). High-risk coronary lesion types can be accurately categorized by MDCT. This ability may allow MDCT to play an important noninvasive role in the planning of coronary interventions.
Ugurel, M S; Battal, B; Bozlar, U; Nural, M S; Tasar, M; Ors, F; Saglam, M; Karademir, I
2010-08-01
The purpose of our investigation was to determine the anatomical variations in the coeliac trunk-hepatic arterial system and the renal arteries in patients who underwent multidetector CT (MDCT) angiography of the abdominal aorta for various reasons. A total of 100 patients were analysed retrospectively. The coeliac trunk, hepatic arterial system and renal arteries were analysed individually and anatomical variations were recorded. Statistical analysis of the relationship between hepatocoeliac variations and renal artery variations was performed using a chi(2) test. There was a coeliac trunk trifurcation in 89% and bifurcation in 8% of the cases. Coeliac trunk was absent in 1%, a hepatosplenomesenteric trunk was seen in 1% and a splenomesenteric trunk was present in 1%. Hepatic artery variation was present in 48% of patients. Coeliac trunk and/or hepatic arterial variation was present in 23 (39.7%) of the 58 patients with normal renal arteries, and in 27 (64.3%) of the 42 patients with accessory renal arteries. There was a statistically significant correlation between renal artery variations and coeliac trunk-hepatic arterial system variations (p = 0.015). MDCT angiography permits a correct and detailed evaluation of hepatic and renal vascular anatomy. The prevalence of variations in the coeliac trunk and/or hepatic arteries is increased in people with accessory renal arteries. For that reason, when undertaking angiographic examinations directed towards any single organ, the possibility of variations in the vascular structure of other organs should be kept in mind.
Qi, Rui; Zhou, Xiangping; Yu, Jianqun; Li, Zhenlin
2014-04-01
This study aims to explore the inferior adhesion of the renal fascia (RF), and the inferior connectivity of the perirenal spaces (PS) with multidetector computed tomography (MDCT), and to investigate the diagnostic value of CT for showing this anatomy. From May to July 2012, eighty-two patients with acute pancreatitis presented in our hospital were enrolled into this study and underwent contrast-enhanced CT scans. All the image data were used to perform three dimensional reconstruction to show the inferior attachment of RF and the inferior connectivity of PS. The fusion of anterior renal fascia (ARF) and posterior renal fascia (PRF) next to the plane of iliac fossa were found on the left in 71.95% (59/82) cases, and on the right in 75.61% (62/82). In these cases, bilateral perirenal spaces, and anterior and posterior pararenal spaces were not found to be connected with each other. No fusion of ARF and PRF below the level of bilateral kidneys occurred on the left side in 28.05% (23/82) cases and on the right side in 24.39% (20/82). In these patients, the PS extended to the extraperitoneal space of the pelvic cavity and further to the inguinal region, and bilateral anterior and posterior pararenal spaces were not found to be connected with each other. Three-dimensional reconstruction on contrast-enhanced MDCT could be a valuable procedure for depicting inferior attachment of RF, and the inferior connectivity of PS.
Multidetector CT of Surgically Proven Blunt Bowel and Mesenteric Injury.
Bates, David D B; Wasserman, Michael; Malek, Anita; Gorantla, Varun; Anderson, Stephan W; Soto, Jorge A; LeBedis, Christina A
2017-01-01
Blunt traumatic injury is one of the leading causes of morbidity and mortality in the United States. Unintentional injury represents the leading cause of death in the United States for all persons between the ages of 1 and 44 years. In the setting of blunt abdominal trauma, the reported rate of occurrence of bowel and mesenteric injuries ranges from 1% to 5%. Despite the relatively low rate of blunt bowel and mesenteric injury in patients with abdominal and pelvic trauma, delays in diagnosis are associated with increased rates of sepsis, a prolonged course in the intensive care unit, and increased mortality. During the past 2 decades, as multidetector computed tomography (CT) has emerged as an essential tool in emergency radiology, several direct and indirect imaging features have been identified that are associated with blunt bowel and mesenteric injury. The imaging findings in cases of blunt bowel and mesenteric injury can be subtle and may be seen in the setting of multiple complex injuries, such as multiple solid-organ injuries and spinal fractures. Familiarity with the various imaging features of blunt bowel and mesenteric injury, as well as an understanding of their clinical importance with regard to the care of the patient, is essential to making a timely diagnosis. Once radiologists are familiar with the spectrum of findings of blunt bowel and mesenteric injury, they will be able to make timely diagnoses that will lead to improved patient outcomes. © RSNA, 2017.
Selberherr, Andreas; Hörmann, Marcus; Prager, Gerhard; Riss, Philipp; Scheuba, Christian; Niederle, Bruno
2017-03-01
The purpose of this study was to demonstrate the high number of kidney stones in primary hyperparathyroidism (PHPT) and the low number of in fact "asymptomatic" patients. Forty patients with PHPT (28 female, 12 male; median age 58 (range 33-80) years; interquartile range 17 years [51-68]) without known symptoms of kidney stones prospectively underwent multidetector computed tomography (MDCT) and ultrasound (US) examinations of the urinary tract prior to parathyroid surgery. Images were evaluated for the presence and absence of stones, as well as for the number of stones and sizes in the long axis. The MDCT and US examinations were interpreted by two experienced radiologists who were blinded to all clinical and biochemical data. Statistical analysis was performed using the Wilcoxon signed-rank test. US revealed a total of 4 kidney stones in 4 (10 %) of 40 patients (median size 6.5 mm, interquartile range 11.5 mm). MDCT showed a total of 41 stones (median size was 3 mm, interquartile range 2.25 mm) in 15 (38 %) of 40 patients. The number of kidney stones detected with MDCT was significantly higher compared to US (p = 0.00124). MDCT is a highly sensitive method for the detection of "silent" kidney stones in patients with PHPT. By widely applying this method, the number of asymptomatic courses of PHPT may be substantially reduced. MDCT should be used primarily to detect kidney stones in PHPT and to exclude asymptomatic PHPT.
Norris, Joseph M; Kishikova, Lyudmila; Avadhanam, Venkata S; Koumellis, Panos; Francis, Ian S; Liu, Christopher S C
2015-08-01
To investigate the efficacy of 640-slice multidetector computed tomography (MDCT) for detecting osteo-odonto laminar resorption in the osteo-odonto-keratoprosthesis (OOKP) compared with the current standard 32-slice MDCT. Explanted OOKP laminae and bone-dentine fragments were scanned using 640-slice MDCT (Aquilion ONE; Toshiba) and 32-slice MDCT (LightSpeed Pro32; GE Healthcare). Pertinent comparisons including image quality, radiation dose, and scanning parameters were made. Benefits of 640-slice MDCT over 32-slice MDCT were shown. Key comparisons of 640-slice MDCT versus 32-slice MDCT included the following: percentage difference and correlation coefficient between radiological and anatomical measurements, 1.35% versus 3.67% and 0.9961 versus 0.9882, respectively; dose-length product, 63.50 versus 70.26; rotation time, 0.175 seconds versus 1.000 seconds; and detector coverage width, 16 cm versus 2 cm. Resorption of the osteo-odonto lamina after OOKP surgery can result in potentially sight-threatening complications, hence it warrants regular monitoring and timely intervention. MDCT remains the gold standard for radiological assessment of laminar resorption, which facilitates detection of subtle laminar changes earlier than the onset of clinical signs, thus indicating when preemptive measures can be taken. The 640-slice MDCT exhibits several advantages over traditional 32-slice MDCT. However, such benefits may not offset cost implications, except in rare cases, such as in young patients who might undergo years of radiation exposure.
Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I
2017-08-01
A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p < 0.01), superior scalar localization (p < 0.01), and reduced blooming artifact (p < 0.05), compared with conventional 64-slice MDCT. There was no significant difference between platforms when comparing streak or ring artifact. The new generation 192-slice MDCT scanner offers several notable advantages for cochlear implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.
Cho, S H; Sung, Y M; Kim, M S
2012-10-01
The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images.
Yahaba, Misuzu; Kawata, Naoko; Iesato, Ken; Matsuura, Yukiko; Sugiura, Toshihiko; Kasai, Hajime; Sakurai, Yoriko; Terada, Jiro; Sakao, Seiichiro; Tada, Yuji; Tanabe, Nobuhiro; Tatsumi, Koichiro
2014-06-01
Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation caused by emphysema and small airway narrowing. Quantitative evaluation of airway dimensions by multi-detector computed tomography (MDCT) has revealed a correlation between airway dimension and airflow limitation. However, the effect of emphysema on this correlation is unclear. The goal of this study was to determine whether emphysematous changes alter the relationships between airflow limitation and airway dimensions as measured by inspiratory and expiratory MDCT. Ninety-one subjects underwent inspiratory and expiratory MDCT. Images were evaluated for mean airway luminal area (Ai), wall area percentage (WA%) from the third to the fifth generation of three bronchi (B1, B5, B8) in the right lung, and low attenuation volume percent (LAV%). Correlations between each airway index and airflow limitation were determined for each patient and compared between patients with and without evidence of emphysema. In patients without emphysema, Ai and WA% from both the inspiratory and expiratory scans were significantly correlated with FEV1. No correlation was detected in patients with emphysema. In addition, emphysematous COPD patients with GOLD stage 1 or 2 disease had significantly lower changes in B8 Ai than non-emphysematous patients. A significant correlation exists between airway parameters and FEV1 in patients without emphysema. Emphysema may influence airway dimensions even in patients with mild to moderate COPD. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Jung, Chang Hee; Hwang, Jenie Yoonoo; Shin, Mi Seon; Yu, Ji Hee; Kim, Eun Hee; Bae, Sung Jin; Yang, Dong Hyun; Kang, Joon-Won; Park, Joong-Yeol; Kim, Hong-Kyu
2013-01-01
Despite the noninvasiveness and accuracy of multidetector computed tomography (MDCT), its use as a routine screening tool for occult coronary atherosclerosis is unclear. We investigated whether the ratio of apolipoprotein B (apoB) to apolipoprotein A1 (apoA1), an indicator of the balance between atherogenic and atheroprotective cholesterol transport could predict occult coronary atherosclerosis detected by MDCT. We collected the data of 1,401 subjects (877 men and 524 women) who participated in a routine health screening examination of Asan Medical Center. Significant coronary artery stenosis defined as > 50% stenosis was detected in 114 subjects (8.1%). An increase in apoB/A1 quartiles was associated with increased percentages of subjects with significant coronary stenosis and noncalcified plaques (NCAP). After adjustment for confounding variables, each 0.1 increase in serum apoB/A1 was significantly associated with increased odds ratios (ORs) for coronary stenosis and NCAP of 1.23 and 1.18, respectively. The optimal apoB/A1 ratio cut off value for MDCT detection of significant coronary stenosis was 0.58, which had a sensitivity of 70.2% and a specificity of 48.2% (area under the curve, 0.61; 95% CI, 0.58-0.63, P < 0.001). Our results indicate that apoB/A1 ratio is a good indicator of occult coronary atherosclerosis detected by coronary MDCT. PMID:23678262
Jung, Chang Hee; Hwang, Jenie Yoonoo; Shin, Mi Seon; Yu, Ji Hee; Kim, Eun Hee; Bae, Sung Jin; Yang, Dong Hyun; Kang, Joon-Won; Park, Joong-Yeol; Kim, Hong-Kyu; Lee, Woo Je
2013-05-01
Despite the noninvasiveness and accuracy of multidetector computed tomography (MDCT), its use as a routine screening tool for occult coronary atherosclerosis is unclear. We investigated whether the ratio of apolipoprotein B (apoB) to apolipoprotein A1 (apoA1), an indicator of the balance between atherogenic and atheroprotective cholesterol transport could predict occult coronary atherosclerosis detected by MDCT. We collected the data of 1,401 subjects (877 men and 524 women) who participated in a routine health screening examination of Asan Medical Center. Significant coronary artery stenosis defined as > 50% stenosis was detected in 114 subjects (8.1%). An increase in apoB/A1 quartiles was associated with increased percentages of subjects with significant coronary stenosis and noncalcified plaques (NCAP). After adjustment for confounding variables, each 0.1 increase in serum apoB/A1 was significantly associated with increased odds ratios (ORs) for coronary stenosis and NCAP of 1.23 and 1.18, respectively. The optimal apoB/A1 ratio cut off value for MDCT detection of significant coronary stenosis was 0.58, which had a sensitivity of 70.2% and a specificity of 48.2% (area under the curve, 0.61; 95% CI, 0.58-0.63, P < 0.001). Our results indicate that apoB/A1 ratio is a good indicator of occult coronary atherosclerosis detected by coronary MDCT.
Annoni, Andrea Daniele; Mancini, Maria E; Andreini, Daniele; Formenti, Alberto; Mushtaq, Saima; Nobili, Enrica; Guglielmo, Marco; Baggiano, Andrea; Conte, Edoardo; Pepi, Mauro
2017-10-01
Multidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol. Two-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100 Kvp tube voltage), Group C (Iomeprol 400 and 80 Kvp tube voltage) and Group D (Iomeprol 400 and 100 Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups. No significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80 kV versus groups using 100 kV but without differences in terms of image quality. ED was significantly lower in groups with 80 kV. Multidetector Computed Tomography Angiography protocols using 80 kV and low concentration contrast media are feasible without need of tailored injection protocols. © 2017 The Royal Australian and New Zealand College of Radiologists.
He, Xiaoning; Holtorf, Anke-Peggy; Rinde, Harald; Xie, Shuangshuang; Shen, Wen; Hou, Jiancun; Li, Xuehua; Li, Ziping; Lai, Jiaming; Wang, Yuting; Zhang, Lin; Wang, Jian; Li, Xuesong; Ma, Kuansheng; Ye, Feng; Ouyang, Han; Zhao, Hong
2018-01-01
Limited data exists in China on the comparative cost of gadolinium ethoxybenzyl diethylenetriamine magnetic resonance imaging (Gd-EOB-DTPA-MRI) with other imaging techniques. This study compared the total cost of Gd-EOB-DTPA-MRI with multidetector computed tomography (MDCT) and extracellular contrast media–enhanced MRI (ECCM-MRI) as initial imaging procedures in patients with suspected hepatocellular carcinoma (HCC). We developed a decision-tree model on the basis of the Chinese clinical guidelines for HCC, which was validated by clinical experts from China. The model compared the diagnostic accuracy and costs of alternative initial imaging procedures. Compared with MDCT and ECCM-MRI, Gd-EOB-DTPA-MRI imaging was associated with higher rates of diagnostic accuracy, i.e. higher proportions of true positives (TP) and true negatives (TN) with lower false positives (FP). Total diagnosis and treatment cost per patient after the initial Gd-EOB-DTPA-MRI evaluation was similar to MDCT (¥30,360 vs. ¥30,803) and lower than that reported with ECCM-MRI (¥30,360 vs. ¥31,465). Lower treatment cost after initial Gd-EOB-DTPA-MRI was driven by reduced utilization of confirmatory diagnostic procedures and unnecessary treatments. The findings reported that Gd-EOB-DTPA-MRI offered higher diagnostic accuracy compared with MDCT and ECCM-MRI at a comparable cost, which indicates Gd-EOB-DTPA-MRI could be the preferred initial imaging procedure for the diagnosis of HCC in China. PMID:29324837
Mandich Crovetto, D; Alonso Charterina, S; Jiménez López-Guarch, C; Pont Vilalta, M; Pérez Núñez, M; de Pablo Gafas, A; Escribano Subías, P
2016-01-01
To use multidetector computed tomography (MDCT) to evaluate the structural changes in the right heart and pulmonary arteries that occur in patients with severe pulmonary hypertension treated by double lung transplantation. This was a retrospective study of 21 consecutive patients diagnosed with severe pulmonary hypertension who underwent double lung transplantation at our center between 2010 and 2014. We analyzed the last MDCT study done before lung transplantation and the first MDCT study done after lung transplantation. We recorded the following variables: diameter of the pulmonary artery trunk, ratio of the diameter of the pulmonary artery trunk to the diameter of the ascending aorta, diameter of the right ventricle, ratio of the diameter of the left ventricle to the diameter of the right ventricle, and eccentricity index. Statistical analysis consisted of the comparison of the means of the variables recorded. In all cases analyzed, the MDCT study done a mean of 24±14 days after double lung transplantation showed a significant reduction in the size of the right heart chambers, with improved indices of ventricular interdependency index, and reduction in the size of the pulmonary artery trunk (p<0.001 for all the variables analyzed). Patients with pulmonary hypertension treated by double lung transplantation present early reverse remodeling of the changes in the structures of the right heart and pulmonary arterial tree. MDCT is useful for detecting these changes. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Takahashi, Masashi; Ohashi, Hirofumi
2013-06-01
Costello syndrome is a rare multiple congenital anomaly syndrome caused by heterozygous germline HRAS mutations, which is characterized by intellectual disability, growth retardation, distinctive facies, loose skin, cardiomyopathy and a preposition to malignancies. Although teeth abnormalities have been encountered in nearly two-thirds of the patients in literature, the evaluation tended to be limited to the extent which can be obtained from physical examination. We investigated detailed craniofacial, oral and dental findings in four patients with Costello syndrome. In this study, images reconstructed by multi-detector row computed tomography (MDCT) were used as substitutes for dental cast study and panoramic and lateral cephalometric radiograph studies to evaluate dental arches, tooth size, relationships between craniofacial and dental structures, and hypodontia. All four patients showed true/relative macrocephaly with facial bone hypoplasia and gingival hypertrophy. Occlusal attrition, malocclusion, small dental arches, microdontia, and convex face were noted in three patients. In addition, one patient showed dental caries, conic tooth and gingivitis, and another patient showed hypodontia. Our study suggests that craniofacial and dental abnormalities are common in Costello syndrome patients and comprehensive dental care should be provided from early infancy. To our knowledge, this is the first study of thorough craniofacial and dental evaluation by using MDCT in Costello syndrome. MDCT is a useful tool for precise evaluation of craniofacial and oral manifestations in patients with congenital anomaly/intellectual disability syndromes. © 2012 The Authors. Congenital Anomalies © 2012 Japanese Teratology Society.
Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M.
2016-01-01
Purpose To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. Methods As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Results Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = < .004). No significant differences were detected concerning the modalities’ specificities (with values between P = .98). Raters' confidence was higher in RED-MDCT and RED-CBCT compared to radiography (P < .001). Conclusion The diagnostic accuracy of RED-MDCT and RED-CBCT for wrist fractures proved to be similar and in some parts even higher compared to radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run. PMID:27788215
Kim, Jong Gyu
2012-01-01
Background During the planning of a thoracodorsal artery perforator (TDAP) free flap, preoperative multidetector-row computed tomographic (MDCT) angiography is valuable for predicting the locations of perforators. However, CT-based perforator mapping of the thoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thick MDCT images in multiple planes to search for reliable perforators accurately. Methods Between July 2010 and October 2011, 19 consecutive patients (13 males, 6 females) who underwent MDCT prior to TDAP free flap operations were enrolled in this study. Patients ranged in age from 10 to 75 years (mean, 39.3 years). MDCT images were acquired at a thickness of 1 mm in the axial, coronal, and sagittal planes. Results The thoracodorsal artery perforators were detected in all 19 cases. The reliable perforators originating from the descending branch were found in 14 cases, of which 6 had transverse branches. The former were well identified in the coronal view, and the latter in the axial view. The location of the most reliable perforators on MDCT images corresponded well with the surgical findings. Conclusions Though MDCT has been widely used in performing the abdominal perforator free flap for detecting reliable perforating vessels, it is not popular in the TDAP free flap. The results of this study suggest that multiple planes of MDCT may increase the probability of detecting the most reliable perforators, along with decreasing the probability of missing available vessels. PMID:22872839
Epicardial adipose tissue as a predictor of coronary artery disease in asymptomatic subjects.
Bachar, Gil N; Dicker, Dror; Kornowski, Ran; Atar, Eli
2012-08-15
This study sought to elucidate the relation between epicardial adipose tissue (EAT) thickness measured by multidetector computed tomography and presence of coronary artery atherosclerosis. Recent studies have suggested that fat disposition in visceral organs and epicardial tissue could serve as a predictor of coronary artery disease (CAD). The sample included 190 asymptomatic subjects with ≥ 1 cardiovascular risk factor who were referred for cardiac computed tomographic angiography. Body mass index, blood pressure, fasting glucose level, and lipid profile were measured. Multidetector computed tomographic results were analyzed for atherosclerosis burden, calcium Agatston score, and EAT thickness: mean EAT values were 3.54 ± 1.59 mm in patients with atherosclerosis and 1.85 ± 1.28 mm in patients without atherosclerosis (p <0.001). On receiver operating characteristic analysis, an EAT value ≥ 2.4 mm predicted the presence of significant (>50% diameter) coronary artery stenosis. There was a significant difference in EAT values between patients with and without metabolic syndrome (2.58 ± 1.63 vs 2.04 ± 1.46 mm, p <0.05) and between patients with a calcium score >400 and <400 (3.38 ± 1.58 vs 2.02 ± 1.42 mm, p <0.0001). In conclusion, asymptomatic patients with CAD have significantly more EAT than patients without CAD. An EAT thickness of 2.4 mm is the optimal cutoff for prediction of presence of significant CAD. Copyright © 2012 Elsevier Inc. All rights reserved.
Jones, Jeryl C; Appt, Susan E; Bourland, J Daniel; Hoyer, Patricia B; Clarkson, Thomas B; Kaplan, Jay R
2007-09-01
Macaques are important models for menopause and associated diseases in women. A sensitive, noninvasive technique for quantifying changes in ovarian morphology would facilitate longitudinal studies focused on the health-related sequelae of naturally occurring or experimentally induced alterations in ovarian structure and function. Multidetector computed tomography (MDCT) is a fast, non-invasive imaging technique that uses X-rays, multiple rows of detectors, and computers to generate detailed slice images of structures. The purpose of this study was to describe the utility of MDCT for reliably characterizing ovarian morphology in macaques. Five macaques were scanned using contrast-enhanced MDCT. The following characteristics were described: 1) appearance of ovaries and adjacent landmarks, 2) effects of varying technical protocols on ovarian image quality, 3) radiation doses delivered to the pelvic region during scanning, and 4) MDCT estimates of ovarian volume and antral follicle counts versus those measured directly in ovarian tissue. Ovaries were distinguishable in all MDCT scans and exhibited heterogeneous contrast enhancement. Antral follicles appeared as focal areas of nonenhancement. Ovarian image quality with 5 pediatric scanning protocols was sufficient for discriminating ovarian margins. Pelvic region radiation doses ranged from 0.5 to 0.7 rad. Antral follicles counted using MDCT ranged from 3 to 5 compared with 3 to 4 counted using histology. Ovarian volumes measured using MDCT ranged from 0.41 to 0.67 ml compared with 0.40 to 0.65 ml by water displacement. MDCT is a promising technique for measuring longitudinal changes in macaque ovarian morphology reliably and noninvasively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferro, Carlo; Rossi, Umberto G., E-mail: urossi76@hotmail.com; Bovio, Giulio
2007-09-15
A patient was admitted because of severe abdominal pain, anorexia, and intestinal bleeding. Contrast-enhanced multidetector computed tomography demonstrated acute portal and superior mesenteric vein thrombosis (PSMVT). The patient was treated percutaneously with transjugular intrahepatic portosystemic shunt (TIPS), mechanical aspiration thrombectomy, and direct thrombolysis, and 1 week after the procedure, complete patency of the portal and superior mesenteric veins was demonstrated. TIPS, mechanical aspiration thrombectomy, and direct thrombolysis together are promising endovascular techniques for the treatment of symptomatic acute PSMVT.
Real-time operating system for a multi-laser/multi-detector system
NASA Technical Reports Server (NTRS)
Coles, G.
1980-01-01
The laser-one hazard detector system, used on the Rensselaer Mars rover, is reviewed briefly with respect to the hardware subsystems, the operation, and the results obtained. A multidetector scanning system was designed to improve on the original system. Interactive support software was designed and programmed to implement real time control of the rover or platform with the elevation scanning mast. The formats of both the raw data and the post-run data files were selected. In addition, the interface requirements were selected and some initial hardware-software testing was completed.
Appendiceal hemorrhage -- an uncommon cause of lower gastrointestinal bleeding.
Chiang, Ching-Chung; Tu, Chi-Wen; Liao, Chi-Szu; Shieh, Min-Chieh; Sung, Tien-Chou
2011-06-01
Lower gastrointestinal bleeding is a common disease among elderly patients. The common sources of lower gastrointestinal bleeding include vascular disease, Crohn's disease, neoplasms, inflammatory bowel disease, hemorrhoids, and ischemic colitis. Lower gastrointestinal bleeding arising from the appendix is an extremely rare condition. We report a case of appendiceal hemorrhage in a young male. Diagnosis was made by multidetector computerized tomography during survey for hematochezia. The patient recovered well after appendectomy. The histological finding revealed focal erosion of appendix mucosa with bleeding. Copyright © 2011. Published by Elsevier B.V.
Lane, John I; Witte, Robert J; Driscoll, Colin L W; Shallop, Jon K; Beatty, Charles W; Primak, Andrew N
2007-08-01
To use the improved resolution available with 64-slice multidetector computed tomography (MDCT) in vivo to localize the cochlear implant electrode array within the basal turn. Sixty-four-slice MDCT examinations of the temporal bones were retrospectively reviewed in 17 patients. Twenty-three implants were evaluated. Tertiary referral facility. All patients with previous cochlear implantation evaluated at our center between January 2004 and March 2006 were offered a computed tomographic examination as part of the study. In addition, preoperative computed tomographic examinations in patients being evaluated for a second bilateral device were included. Sixty-four-slice MDCT examination of the temporal bones. Localization of the electrode array within the basal turn from multiplanar reconstructions of the cochlea. Twenty-three implants were imaged in 17 patients. We were able to localize the electrode array within the scala tympani within the basal turn in 10 implants. In 3 implants, the electrode array was localized to the scala vestibuli. Migration of the electrode array from scala tympani to scala vestibuli was observed in three implants. Of the 7 implants in which localization of the electrode array was indeterminate, all had disease entities that obscured the definition of the normal cochlear anatomy. Sixty-four-slice MDCT with multiplanar reconstructions of the postoperative cochlea after cochlear implantation allows for accurate localization of the electrode array within the basal turn where normal cochlear anatomy is not obscured by the underlying disease process. Correlating the position of the electrode in the basal turn with surgical technique and implant design could be helpful in improving outcomes.
Tan, J S P; Tan, K-L; Lee, J C L; Wan, C-M; Leong, J-L; Chan, L-L
2009-02-01
To our knowledge, there has been no study that compares the radiation dose delivered to the eye lens by 16- and 64-section multidetector CT (MDCT) for standard clinical neuroimaging protocols. Our aim was to assess radiation-dose differences between 16- and 64-section MDCT from the same manufacturer, by using near-identical neuroimaging protocols. Three cadaveric heads were scanned on 16- and 64-section MDCT by using standard neuroimaging CT protocols. Eye lens dose was measured by using thermoluminescent dosimeters (TLD), and each scanning was repeated to reduce random error. The dose-length product, volume CT dose index (CTDI(vol)), and TLD readings for each imaging protocol were averaged and compared between scanners and protocols, by using the paired Student t test. Statistical significance was defined at P < .05. The radiation dose delivered and eye lens doses were lower by 28.1%-45.7% (P < .000) on the 64-section MDCT for near-identical imaging protocols. On the 16-section MDCT, lens dose reduction was greatest (81.1%) on a tilted axial mode, compared with a nontilted helical mode for CT brain scans. Among the protocols studied, CT of the temporal bone delivered the greatest radiation dose to the eye lens. Eye lens radiation doses delivered by the 64-section MDCT are significantly lower, partly due to improvements in automatic tube current modulation technology. However, where applicable, protection of the eyes from the radiation beam by either repositioning the head or tilting the gantry remains the best way to reduce eye lens dose.
Hirakuri, Ayaka; Numasawa, Kanako; Takeishi, Hideki; Satomura, Minato; Takeda, Hiromitsu; Harada, Kuniaki; Asanuma, Osamu; Sakata, Motomichi
2012-01-01
The exposure of the eye lens caused by multi-detector row computed tomography (MDCT) of the temporal bone is a serious problem. Our aim was to evaluate the radiation dose to the eye lens by different scan baselines (orbitomeatal line; OML, acanthiomeatal line; AML) and examine the difference of the depiction of the temporal bone structures. Measurement of the exposure to the eye lens was performed by means of MDCT of the temporal bone with a radio-photoluminescence glass dosimeter using a rand phantom. Moreover, we studied only one volunteer (58-year-old male) who had no symptom and was not suspected of having any ear abnormalities with a two scan baseline. Visualization of the major anatomical structures of the temporal bone (the tympanic portion of the facial nerve canal, the body of the incus, stapes superstructures, vestibule etc.) was performed on the volunteer. The average absorbed dose was 6.42 mGy by the OML and 1.59 mGy by the AML, respectively. With regard to visualization of the temporal bone structures, all structures were of equal quality with the two scan baseline. With the AML line, the radiation dose to the eye lens was reduced to 75%. Therefore, the authors recommended an AML for use for MDCT of the temporal bone. In clinical practice, the optimization of scanning factor (kVp, mAs etc.) and the use of the radio-protection should be implemented for radiation dose reduction of the eye lens by MDCT of the temporal bone.
Nagy, Eszter; Apfaltrer, Georg; Riccabona, Michael; Singer, Georg; Stücklschweiger, Georg; Guss, Helmuth; Sorantin, Erich
2017-01-01
Objectives To evaluate and compare surface doses of a cone beam computed tomography (CBCT) and a multidetector computed tomography (MDCT) device in pediatric ankle and wrist phantoms. Methods Thermoluminescent dosimeters (TLD) were used to measure and compare surface doses between CBCT and MDCT in a left ankle and a right wrist pediatric phantom. In both modalities adapted pediatric dose protocols were utilized to achieve realistic imaging conditions. All measurements were repeated three times to prove test-retest reliability. Additionally, objective and subjective image quality parameters were assessed. Results Average surface doses were 3.8 ±2.1 mGy for the ankle, and 2.2 ±1.3 mGy for the wrist in CBCT. The corresponding surface doses in optimized MDCT were 4.5 ±1.3 mGy for the ankle, and 3.4 ±0.7 mGy for the wrist. Overall, mean surface dose was significantly lower in CBCT (3.0 ±1.9 mGy vs. 3.9 ±1.2 mGy, p<0.001). Subjectively rated general image quality was not significantly different between the study protocols (p = 0.421), whereas objectively measured image quality parameters were in favor of CBCT (p<0.001). Conclusions Adapted extremity CBCT imaging protocols have the potential to fall below optimized pediatric ankle and wrist MDCT doses at comparable image qualities. These possible dose savings warrant further development and research in pediatric extremity CBCT applications. PMID:28570626
Çiledağ, Nazan; Arda, Kemal; Arıbaş, Bilgin Kadri; Tekgündüz, Ali Irfan Emre; Altuntaş, Fevzi
2012-01-01
Objective: To evaluate vessel involvement and the role of multidetector computed tomography (MDCT) in the earlydiagnosis of invasive pulmonary aspergillosis (IPA) in patients with febrile neutropenia and antibiotic-resistant feverundergoing autologous bone morrow transplantation. Material and Methods: In all, 74 pulmonary MDCT examinations in 37 consecutive hematopoietic stem celltransplantation patients with febrile neutropenia and clinically suspected IPA were retrospectively evaluated. Results: Diagnosis of IPA was based on Fungal Infections Cooperative Group, and National Institute of Allergy andInfectious Diseases Mycoses Study Consensus Group criteria. In all, 0, 14, and 11 patients were diagnosed as proven,probable, and possible IPA, respectively. Among the 25 patients accepted as probable and possible IPA, all had pulmonaryMDCT findings consistent with IPA. The remaining 12 patients were accepted as having fever of unknown origin (FUO)and had patent vessels based on MDCT findings.In the patients with probable and possible IPA, 72 focal pulmonary lesions were observed; in 41 of the 72 (57%) lesionsvascular occlusion was noted and the CT halo sign was observed in 25 of these 41 (61%) lesions. Resolution of feveroccurred following antifungal therapy in 19 (76%) of the 25 patients with probable and possible IPA. In all, 6 (25%)of the patients diagnosed as IPA died during follow-up. Transplant-related mortality 100 d post transplant in patientswith IPA and FUO was 24% and 0%, respectively. Conclusion: In conclusion, MDCT has a potential role in the early diagnosis of IPA via detection of vessel occlusion. PMID:24744620
Specchi, Swan; d'Anjou, Marc-André; Carmel, Eric Norman; Bertolini, Giovanna
2014-01-01
Collateral venous pathways develop in dogs with obstruction or increased blood flow resistance at any level of the caudal vena cava in order to maintain venous drainage to the right atrium. The purpose of this retrospective study was to describe the sites, causes of obstruction, and configurations of venous collateral pathways for a group of dogs with caudal vena cava obstruction. Computed tomography databases from two veterinary hospitals were searched for dogs with a diagnosis of caudal vena cava obstruction and multidetector row computed tomographic angiographic (CTA) scans that included the entire caudal vena cava. Images for each included dog were retrieved and collateral venous pathways were characterized using image postprocessing and a classification system previously reported for humans. A total of nine dogs met inclusion criteria and four major collateral venous pathways were identified: deep (n = 2), portal (n = 2), intermediate (n = 7), and superficial (n = 5). More than one collateral venous pathway was present in 5 dogs. An alternative pathway consisting of renal subcapsular collateral veins, arising mainly from the caudal pole of both kidneys, was found in three dogs. In conclusion, findings indicated that collateral venous pathway patterns similar to those described in humans are also present in dogs with caudal vena cava obstruction. These collateral pathways need to be distinguished from other vascular anomalies in dogs. Postprocessing of multidetector-row CTA images allowed delineation of the course of these complicated venous pathways and may be a helpful adjunct for treatment planning in future cases. © 2014 American College of Veterinary Radiology.
Le Couteulx, S; Caudron, J; Dubourg, B; Cauchois, G; Dupré, M; Michelin, P; Durand, E; Eltchaninoff, H; Dacher, J-N
2018-05-01
To evaluate intra- and inter-observer variability of multidetector computed tomography (MDCT) sizing of the aortic annulus before transcatheter aortic valve replacement (TAVR) and the effect of observer experience, aortic valve calcification and image quality. MDCT examinations of 52 consecutive patients with tricuspid aortic valve (30 women, 22 men) with a mean age of 83±7 (SD) years (range: 64-93 years) were evaluated retrospectively. The maximum and minimum diameters, area and circumference of the aortic annulus were measured twice at diastole and systole with a standardized approach by three independent observers with different levels of experience (expert [observer 1]; resident with intensive 6 months practice [observer 2]; trained resident with starting experience [observer 3]). Observers were requested to recommend the valve prosthesis size. Calcification volume of the aortic valve and signal to noise ratio were evaluated. Intra- and inter-observer reproducibility was excellent for all aortic annulus dimensions, with an intraclass correlation coefficient ranging respectively from 0.84 to 0.98 and from 0.82 to 0.97. Agreement for selection of prosthesis size was almost perfect between the two most experienced observers (k=0.82) and substantial with the inexperienced observer (k=0.67). Aortic valve calcification did not influence intra-observer reproducibility. Image quality influenced reproducibility of the inexperienced observer. Intra- and inter-observer variability of aortic annulus sizing by MDCT is low. Nevertheless, the less experienced observer showed lower reliability suggesting a learning curve. Copyright © 2017. Published by Elsevier Masson SAS.
Multidetector computed tomography urography for diagnosing upper urinary tract urothelial tumour.
Cowan, Nigel C; Turney, Ben W; Taylor, Nia J; McCarthy, Catherine L; Crew, Jeremy P
2007-06-01
To evaluate multidetector computed tomography urography (MDCTU) for diagnosing upper urinary tract (UUT) urothelial tumour by comparison with retrograde ureteropyelography (RUP). MDCTU and RUP were used in a selected series of adult patients presenting with haematuria. Entry criteria were based on findings on intravenous urography and were chosen to ensure a high prevalence of UUT urothelial tumour to allow a valid retrospective comparison of the diagnostic techniques. MDCTU and RUP studies were scored for the presence and absence of UUT urothelial tumour by two radiologists, retrospectively and independently, and while unaware of the demographic and clinical information. The reference standards were the histopathology and clinical follow-up. MDCTU and RUP were used in 106 patients over a 24-month period. RUP was attempted in 151 of 212 UUTs; the corresponding MDCTU for each UUT was reviewed. MDCTU was a true-positive (TP) for urothelial tumour in 31, true-negative (TN) in 111, false-positive (FP) in eight and false-negative (FN) in one UUT, giving a sensitivity of 0.97, a specificity of 0.93, a positive predictive value (PPV) of 0.79 and a negative PV (NPV) of 0.99. RUP was technically successful and diagnostic in 96% of the UUTs (143/151). For diagnosing urothelial tumour, RUP was TP in 26, TN in 112, FP in four and FN in one UUT, giving a sensitivity of 0.97, specificity of 0.93, a PPV of 0.79 and NPV of 0.99. This study validates quantitatively the use of MDCTU for diagnosing UUT urothelial tumour.
Elucidating early CT after pancreatico-duodenectomy: a primer for radiologists.
Tonolini, Massimo; Ierardi, Anna Maria; Carrafiello, Gianpaolo
2018-04-13
Pancreatico-duodenectomy (PD) represents the standard surgical treatment for resectable malignancies of the pancreatic head, distal common bile duct, periampullary region and duodenum, and is also performed to manage selected benign tumours and refractory chronic pancreatitis. Despite improved surgical techniques and acceptable mortality, PD remains a technically demanding, high-risk operation burdened with high morbidity (complication rates 40-50% of patients). Multidetector computed tomography (CT) represents the mainstay modality to rapidly investigate the postoperative abdomen, and to provide a consistent basis for an appropriate choice between conservative, interventional or surgical treatment. However, radiologists require familiarity with the surgically altered anatomy, awareness of expected imaging appearances and possible complications to correctly interpret early post-PD CT studies. This paper provides an overview of surgical indications and techniques, discusses risk factors and clinical manifestations of the usual postsurgical complications, and suggests appropriate techniques and indications for early postoperative CT imaging. Afterwards, the usual, normal early post-PD CT findings are presented, including transient fluid, pneumobilia, delayed gastric emptying, identification of pancreatic gland remnant and of surgical anastomoses. Finally, several imaging examples review the most common and some unusual complications such as pancreatic fistula, bile leaks, abscesses, intraluminal and extraluminal haemorrhage, and acute pancreatitis. • Pancreatico-duodenectomy (PD) is a technically demanding surgery burdened with high morbidity (40-50%). • Multidetector CT is the mainstay technique to investigate suspected complications following PD. • Interpreting post-PD CT requires knowledge of surgically altered anatomy and expected findings. • CT showing collection at surgical site supports clinico-biological diagnosis of pancreatic fistula. • Other complications include biliary leaks, haemorrhage, abscesses and venous thrombosis.
Beliaev, Andrei M; Barber, P Alan; Marshall, Roger J; Civil, Ian
2014-06-01
Blunt cerebrovascular injury (BCVI) occurs in 0.2-2.7% of blunt trauma patients and has up to 30% mortality. Conventional screening does not recognize up to 20% of BCVI patients. To improve diagnosis of BCVI, both an expanded battery of screening criteria and a multi-detector computed tomography angiography (CTA) have been suggested. The aim of this study is to investigate whether the use of CTA restricted to the Denver protocol screen-positive patients would reduce the unnecessary use of CTA as a pre-emptive screening tool. This is a registry-based study of blunt trauma patients admitted to Auckland City Hospital from 1998 to 2012. The diagnosis of BCVI was confirmed or excluded with CTA, magnetic resonance angiography and, if these imaging were non-conclusive, four-vessel digital subtraction angiography. Thirty (61%) BCVI and 19 (39%) non-BCVI patients met eligibility criteria. The Denver protocol applied to our cohort of patients had a sensitivity of 97% (95% confidence interval (CI): 83-100%) and a specificity of 42% (95% CI: 20-67%). With a prevalence of BCVI in blunt trauma patients of 0.2% and 2.7%, post-test odds of a screen-positive test were 0.03 (95% CI: 0.002-0.005) and 0.046 (95% CI: 0.314-0.068), respectively. Application of the CTA to the Denver protocol screen-positive trauma patients can decrease the use of CTA as a pre-emptive screening tool by 95-97% and reduces its hazards. © 2013 Royal Australasian College of Surgeons.
Petrović, Kosta; Turkalj, Ivan; Stojanović, Sanja; Vucaj-Cirilović, Viktorija; Nikolić, Olivera; Stojiljković, Dragana
2013-08-01
Computerized tomography (CT), especially multidetector CT (MDCT), has had a revolutionary impact in diagnostic in traumatized patients. The aim of the study was to identify and compare the frequency of injuries to bone structures of the thorax displayed with 5-mm-thick axial CT slices and thin-slice (MDCT) examination with the use of 3D reconstructions, primarily multiplanar reformations (MPR). This prospective study included 61 patients with blunt trauma submitted to CT scan of the thorax as initial assessment. The two experienced radiologists inde pendently and separately described the findings for 5-mm-thick axial CT slices (5 mm CT) as in monoslice CT examination; MPR and other 3D reconstructions along with thin-slice axial sections which were available in modern MDCT technologies. After describing thin-slice examination in case of disagreement in the findings, the examiners redescribed thin-slice examination together which was ultimately considered as a real, true finding. No statistically significant difference in interobserver evaluation of 5 mm CT examination was recorded (p > 0.05). Evaluation of fractures of sternum with 5 mm CT and MDCT showed a statistically significant difference (p < 0.05) in favor of better display of injury by MDCT examination. MDCT is a powerful diagnostic tool that can describe higher number of bone fractures of the chest in traumatized patients compared to 5 mm CT, especially in the region of sternum for which a statistical significance was obtained using MPR. Moreover, the importance of MDCT is also set by easier and more accurate determination of the level of bone injury.
Kikuchi, Yasuka; Oyama-Manabe, Noriko; Naya, Masanao; Manabe, Osamu; Tomiyama, Yuuki; Sasaki, Tsukasa; Katoh, Chietsugu; Kudo, Kohsuke; Tamaki, Nagara; Shirato, Hiroki
2014-07-01
This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against (15)O-H₂O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P < 0.0001). CFR showed good correlation between dynamic CTP and PET (r = 0.67, P = 0.0126). CFRCT in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. • MBF and CFR can be calculated using dynamic CTP with 320-row MDCT. • MBF and CFR showed good correlation between dynamic CTP and PET. • Lower CFR was well demonstrated in CAD patients by dynamic CTP.
Osteoporosis Imaging: State of the Art and Advanced Imaging
2012-01-01
Osteoporosis is becoming an increasingly important public health issue, and effective treatments to prevent fragility fractures are available. Osteoporosis imaging is of critical importance in identifying individuals at risk for fractures who would require pharmacotherapy to reduce fracture risk and also in monitoring response to treatment. Dual x-ray absorptiometry is currently the state-of-the-art technique to measure bone mineral density and to diagnose osteoporosis according to the World Health Organization guidelines. Motivated by a 2000 National Institutes of Health consensus conference, substantial research efforts have focused on assessing bone quality by using advanced imaging techniques. Among these techniques aimed at better characterizing fracture risk and treatment effects, high-resolution peripheral quantitative computed tomography (CT) currently plays a central role, and a large number of recent studies have used this technique to study trabecular and cortical bone architecture. Other techniques to analyze bone quality include multidetector CT, magnetic resonance imaging, and quantitative ultrasonography. In addition to quantitative imaging techniques measuring bone density and quality, imaging needs to be used to diagnose prevalent osteoporotic fractures, such as spine fractures on chest radiographs and sagittal multidetector CT reconstructions. Radiologists need to be sensitized to the fact that the presence of fragility fractures will alter patient care, and these fractures need to be described in the report. This review article covers state-of-the-art imaging techniques to measure bone mineral density, describes novel techniques to study bone quality, and focuses on how standard imaging techniques should be used to diagnose prevalent osteoporotic fractures. © RSNA, 2012 PMID:22438439
Boulif, Jamila; Gerber, Bernhard; Slimani, Alisson; Lazam, Siham; de Meester, Christophe; Piérard, Sophie; Pasquet, Agnès; Pouleur, Anne-Catherine; Vancraeynest, David; El Khoury, Gébrine; de Kerchove, Laurent; Noirhomme, Philippe; Vanoverschelde, Jean-Louis
To validate aortic valve calcium (AVC) load measurements by multidetector row computed tomography (MDCT), to evaluate the impact of tube potential and slice thickness on AVC scores, to examine the accuracy of AVC load in distinguishing severe from nonsevere aortic stenosis (AS) and to investigate its effectiveness as an alternative diagnosis method when echocardiography remains inconclusive. We prospectively studied 266 consecutive patients with moderate to severe AS who underwent MDCT to measure AVC load and a comprehensive echocardiographic examination to assess AS severity. AVC load was validated against valve weight in 57 patients undergoing aortic valve replacement. The dependence of AVC scores on tube potential and slice thickness was also tested, as well as the relationship between AVC load and echocardiographic criteria of AS severity. MDCT Agatston score correlated well with valve weight (r = 0.82, p < 0.001) and hemodynamic indices of AS severity (all p < 0.001). Ex-vivo Agatston scores decreased significantly with increasing tube potential and slice thickness (repeated measures ANOVA p < 0.001). Multivariate analysis identified mean gradient, the indexed effective orifice area, male gender and left ventricular outflow tract cross-sectional area as independent correlates of the in-vivo AVC load. MDCT-derived AVC load correlated well with valve weight and hemodynamic indices of AS severity. It also depends on tube potential and slice thickness, thus suggesting that these parameters should be standardized to optimize reproducibility and accuracy. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Cho, S H; Sung, Y M; Kim, M S
2012-01-01
Objective The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. Methods 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. Results 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Conclusion Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images. PMID:22514102
Ishii, Namiko; Sakuma, Ayaka; Makino, Yohsuke; Torimitsu, Suguru; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Hoshioka, Yumi; Iwase, Hirotaro; Saitoh, Hisako
2016-09-01
The purpose of this study was to determine the incidence of three-rooted mandibular first molars in a contemporary Japanese population using multidetector computed tomography (MDCT) and examine whether this characteristic root form may be useful for identification purposes. Prior to their forensic autopsies, we obtained MDCT scans of 365 cadavers (255 males, 110 females) with mandibular first molars on both sides. Altogether, 730 mandibular first molars were examined morphologically on reconstructed CT images, and the incidence of three-rooted molars was recorded. The results were analyzed statistically to determine sex and left-right differences using the chi-square test. In all, 189 (25.9%) of the 730 mandibular first molars had three roots: 79 (31.0%) in the 255 males and 35 (31.8%) in the 110 females. No statistically significant difference was found between the sexes. In the 39 individuals who had unilateral three-rooted mandibular first molars, 7 (17.9%) were on the left side and 32 (82.1%) were on the right side, indicating a statistically significant predominance on the right side. The incidence of three-rooted mandibular first molars in contemporary Japanese individuals was 25.9%, with no statistically significant sex difference, but in the case of unilateral three-rooted teeth, with a statistically significant predominance on the right side. Our study found that Japanese and northeastern Asians have a high incidence of the three-rooted mandibular first molars among individuals of Mongolian origin; this finding may be a useful screening tool for identification of unknown individuals. Copyright © 2016. Published by Elsevier Ireland Ltd.
Savić, Živorad N.; Soldatović, Ivan I.; Brajović, Milan D.; Pavlović, Aleksandra M.; Mladenović, Dušan R.; Škodrić-Trifunović, Vesna D.
2011-01-01
The increased thickness of the carotid wall >1 mm is a significant predictor of coronary and cerebrovascular diseases. The purpose of our study was to assess the agreement between multidetector row computed tomography angiography (MDCTA) in measuring carotid artery wall thickness (CAWT) and color Doppler ultrasound (CD-US) in measuring intimae-media thickness (IMT). Eighty-nine patients (aged 35–81) were prospectively analyzed using a 64-detector MDCTA and a CD-US scanner. Continuous data were described as the mean value ± standard deviation, and were compared using the Mann–Whitney U test. A p value <0.05 was considered significant. Bland–Altman statistics were employed to measure the agreement between MDCTA and CD-US. CAWT ranged from 0.62 to 1.60 mm, with a mean value of 1.09 mm. IMT ranged from 0.60 to 1.55 mm, with a mean value of 1.06 mm. We observed an excellent agreement between CD-US and MDCTA in the evaluation of the common carotid artery thickness, with a bias between methods of 0.029 mm (which is a highly statistically important difference of absolute values [t = 43.289; p < 0.01] obtained by paired T test), and limits of agreement from 0.04 to 0.104. Pearson correlation coefficient was 0.9997 (95% CI 0.9996–0.9998; p < 0.01). We conclude that there is an excellent correlation between CAWT and IMT measurements obtained with the MDCTA and CD-US. PMID:22224072
Demehri, S; Muhit, A; Zbijewski, W; Stayman, J W; Yorkston, J; Packard, N; Senn, R; Yang, D; Foos, D; Thawait, G K; Fayad, L M; Chhabra, A; Carrino, J A; Siewerdsen, J H
2015-06-01
To assess visualization tasks using cone-beam CT (CBCT) compared to multi-detector CT (MDCT) for musculoskeletal extremity imaging. Ten cadaveric hands and ten knees were examined using a dedicated CBCT prototype and a clinical multi-detector CT using nominal protocols (80 kVp-108mAs for CBCT; 120 kVp- 300 mAs for MDCT). Soft tissue and bone visualization tasks were assessed by four radiologists using five-point satisfaction (for CBCT and MDCT individually) and five-point preference (side-by-side CBCT versus MDCT image quality comparison) rating tests. Ratings were analyzed using Kruskal-Wallis and Wilcoxon signed-rank tests, and observer agreement was assessed using the Kappa-statistic. Knee CBCT images were rated "excellent" or "good" (median scores 5 and 4) for "bone" and "soft tissue" visualization tasks. Hand CBCT images were rated "excellent" or "adequate" (median scores 5 and 3) for "bone" and "soft tissue" visualization tasks. Preference tests rated CBCT equivalent or superior to MDCT for bone visualization and favoured the MDCT for soft tissue visualization tasks. Intraobserver agreement for CBCT satisfaction tests was fair to almost perfect (κ ~ 0.26-0.92), and interobserver agreement was fair to moderate (κ ~ 0.27-0.54). CBCT provided excellent image quality for bone visualization and adequate image quality for soft tissue visualization tasks. • CBCT provided adequate image quality for diagnostic tasks in extremity imaging. • CBCT images were "excellent" for "bone" and "good/adequate" for "soft tissue" visualization tasks. • CBCT image quality was equivalent/superior to MDCT for bone visualization tasks.
NASA Astrophysics Data System (ADS)
Mulyadin; Dewang, Syamsir; Abdullah, Bualkar; Tahir, Dahlang
2018-03-01
In this study, the image quality of CT scan using phantom American College of Radiology (ACR) was determined. Scanning multidetector CT is used to know the image quality parameters by using a solid phantom containing four modules and primarily from materials that are equivalent to water. Each module is 4 cm in diameter and 20 cm in diameter. There is white alignment marks painted white to reflect the alignment laser and there are also “HEAD”, “FOOT”, and “TOP” marks on the phantom to help align. This test obtains CT images of each module according to the routine inspection protocol of the head. Acceptance of image quality obtained for determination: CT Number Accuracy (CTN), CT Number Uniformity and Noise, Linearity CT Number, Slice Technique, Low Contrast Resolution and High Contrast Resolution represent image quality parameters. In testing CT Number Accuracy (CTN), CT Uniform number and Noise are in the range of tolerable values allowed. In the test, Linearity CT Number obtained correlation value above 0.99 is the relationship between electron density and CT Number. In a low contrast resolution test, the smallest contrast groups are visible. In contrast, the high resolution is seen up to 7 lp/cm. The quality of GE CT Scan is very high, as all the image quality tests obtained are within the tolerance brackets of values permitted by the Nuclear Power Control Agency (BAPETEN). Image quality test is a way to get very important information about the accuracy of snoring result by using phantom ACR.
Shokri, Abbas; Ramezani, Leila; Bidgoli, Mohsen; Akbarzadeh, Mahdi; Ghazikhanlu-Sani, Karim; Fallahi-Sichani, Hamed
2018-03-01
This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values (MGVs) of each cylinder were calculated in each imaging protocol. In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes ( P <.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.
Association between arterial calcifications and nonlacunar and lacunar ischemic strokes.
van Dijk, Anouk C; Fonville, Susanne; Zadi, Taihra; van Hattem, Antonius M G; Saiedie, Ghesrouw; Koudstaal, Peter J; van der Lugt, Aad
2014-03-01
Nonlacunar cerebral infarcts are presumed to be caused by thromboembolism from the heart or extracranial arteries, whereas lacunar infarcts are thought to be caused by small vessel disease. We investigated to what extent arterial calcifications differ between nonlacunar and lacunar ischemic strokes. We studied 820 consecutive patients with transient ischemic attack or ischemic stroke in the anterior circulation who underwent multidetector computed tomography angiography and had no rare cause of stroke. The presence of likely cardioembolic pathogenesis was determined according to the Trial of Org 10172 in Acute Stroke Treatment criteria. The remaining 708 patients were categorized as nonlacunar or lacunar strokes, either transient ischemic attacks or strokes, based on clinical symptoms corrected by brain imaging results. We measured volume of calcifications in the aortic arch, symptomatic extracranial and intracranial carotid artery using multidetector computed tomography angiography. The difference in calcifications between nonlacunar and lacunar strokes was assessed with a multivariable logistic regression analysis. We adjusted for degree of symptomatic carotid artery stenosis and cardiovascular risk factors. We found an independent association between volume of aortic arch calcifications and nonlacunar ischemic strokes (adjusted odds ratio [95% confidence interval], 1.11 [1.02-1.21]). No independent associations between extracranial and intracranial carotid artery calcifications and nonlacunar strokes were present. The only difference we found between nonlacunar and lacunar strokes was a higher calcification volume in the aortic arch in nonlacunar strokes. Our findings only partially confirm the notion of distinct etiologies and suggest that the potential role of other plaque components, plaque morphology, and aortic arch calcifications in ischemic stroke subtypes awaits further evaluation.
Furlan, A; Marin, D; Vanzulli, A; Patera, G Palermo; Ronzoni, A; Midiri, M; Bazzocchi, M; Lagalla, R; Brancatelli, G
2011-01-01
Objectives Our aim was to compare retrospectively hepatic venous and delayed phase images for the detection of tumour washout during multiphasic multidetector row CT (MDCT) of the liver in patients with hepatocellular carcinoma (HCC). Methods 30 cirrhotic patients underwent multiphasic MDCT in the 90 days before liver transplantation. MDCT was performed before contrast medium administration and during hepatic arterial hepatic venous and delayed phases, images were obtained at 12, 55 and 120 s after trigger threshold. Two radiologists qualitatively evaluated images for lesion attenuation. Tumour washout was evaluated subjectively and objectively. Tumour-to-liver contrast (TLC) was measured for all pathologically proven HCCs. Results 48 HCCs were detected at MDCT. 46 of the 48 tumours (96%) appeared as either hyper- or isoattenuating during the hepatic arterial phase subjective washout was present in 15 HCCs (33%) during the hepatic venous phase and in 35 (76%) during the delayed phase (p<0.001, McNemar’s test). Objective washout was present in 30 of the 46 HCCs (65%) during the hepatic venous phase and in 42 of the HCCs (91%) during the delayed phase (p=0.001). The delayed phase yielded significantly higher mean TLC absolute values compared with the hepatic venous phase (−16.1±10.8 HU vs −10.5±10.2 HU; p<0.001). Conclusions The delayed phase is superior to the hepatic venous phase for detection of tumour washout of pathologically proven HCC in cirrhotic patients. PMID:21081569
The Excitation of High Spin States with Quasielastic and Deep Inelastic Reactions.
NASA Astrophysics Data System (ADS)
Knott, Clinton Neal
1988-12-01
The feasibility of populating high spin states using reactions induced by a 220 MeV ^{22 }Ne beam on a ^{170} Er target was studied. The experiment was carried out using a multidetector array for high resolution gamma-ray spectroscopy, a 14 element sum multiplicity spectrometer and six DeltaE-E particle telescopes. Detailed information was obtained concerning the reaction mechanisms associated with various reaction channels. Deep inelastic collisions are shown to be a promising tool for high spin spectroscopy in regions of the chart of nuclides which are not accessible by other reactions.
Bardo, Dianna M E; Brown, Paul
2008-08-01
Cardiac MDCT is here to stay. And, it is more than just imaging coronary arteries. Understanding the differences in and the benefits of one CT scanner from another will help you to optimize the capabilities of the scanner, but requires a basic understanding of the MDCT imaging physics.This review provides key information needed to understand the differences in the types of MDCT scanners, from 64 - 320 detectors, flat panels, single and dual source configurations, step and shoot prospective and retrospective gating, and how each factor influences radiation dose, spatial and temporal resolution, and image noise.
Deconvolution Methods for Multi-Detectors
1989-08-30
in [7). We will say sometimes that the family of distributions jI,..,’m is strongly coprime. It might be useful to explain why is (4) called a...form g In the variable ?. given by n 3(11) g q(z~t,p):= 1 kz()(k k=1 Given a family of m entire holomorphic functions f n’*If m its zero set Z is defined...write g1 g jdk" Recall the k=l coefficients gi are holomorphic in both z and t. Let F be the vector valued holomorphic function F: - (f1 ’..’,f ) we
Radiology of pancreatic neoplasms: An update
de la Santa, Luis Gijón; Retortillo, José Antonio Pérez; Miguel, Ainhoa Camarero; Klein, Lea Marie
2014-01-01
Diagnostic imaging is an important tool to evaluate pancreatic neoplasms. We describe the imaging features of pancreatic malignancies and their benign mimics. Accurate detection and staging are essential for ensuring appropriate selection of patients who will benefit from surgery and for preventing unnecessary surgeries in patients with unresectable disease. Ultrasound, multidetector computed tomography with multiplanar reconstruction and magnetic resonance imaging can help to do a correct diagnosis. Radiologists should be aware of the wide variety of anatomic variants and pathologic conditions that may mimic pancreatic neoplasms. The knowledge of the most important characteristic key findings may facilitate the right diagnosis. PMID:25232458
Radiology of pancreatic neoplasms: An update.
de la Santa, Luis Gijón; Retortillo, José Antonio Pérez; Miguel, Ainhoa Camarero; Klein, Lea Marie
2014-09-15
Diagnostic imaging is an important tool to evaluate pancreatic neoplasms. We describe the imaging features of pancreatic malignancies and their benign mimics. Accurate detection and staging are essential for ensuring appropriate selection of patients who will benefit from surgery and for preventing unnecessary surgeries in patients with unresectable disease. Ultrasound, multidetector computed tomography with multiplanar reconstruction and magnetic resonance imaging can help to do a correct diagnosis. Radiologists should be aware of the wide variety of anatomic variants and pathologic conditions that may mimic pancreatic neoplasms. The knowledge of the most important characteristic key findings may facilitate the right diagnosis.
Population of high spin states by quasi-elastic and deep inelastic collisions
NASA Astrophysics Data System (ADS)
Takai, H.; Knott, C. N.; Winchell, D. F.; Saladin, J. X.; Kaplan, M. S.; de Faro, L.; Aryaeinejad, R.; Blue, R. A.; Ronningen, R. M.; Morrissey, D. J.; Lee, I. Y.; Dietzsch, O.
1988-09-01
The feasibility of populating high spin states using reactions induced by a 10 MeV/nucleon 22Ne beam on 170Er was studied. The experiment was carried out using a multidetector array for high resolution γ-ray spectroscopy, a 14 element sum-multiplicity spectrometer and six ΔE-E telescopes. Detailed information was obtained concerning the reaction mechanisms associated with various reaction channels. Deep inelastic collisions are shown to be a promising tool for high spin spectroscopy in regions of the chart of nuclides which are not accessible by other reactions.
NASA Astrophysics Data System (ADS)
Apel, W. D.; Arteaga, J. C.; Bähren, L.; Bekk, K.; Bertaina, M.; Biermann, P. L.; Blümer, J.; Bozdog, H.; Brancus, I. M.; Buchholz, P.; Cantoni, E.; Chiavassa, A.; Daumiller, K.; de Souza, V.; Di Pierro, F.; Doll, P.; Engel, R.; Falcke, H.; Finger, M.; Fuchs, B.; Fuhrmann, D.; Gemmeke, H.; Grupen, C.; Haungs, A.; Heck, D.; Hörandel, J. R.; Horneffer, A.; Huber, D.; Huege, T.; Isar, P. G.; Kampert, K.-H.; Kang, D.; Krömer, O.; Kuijpers, J.; Link, K.; Łuczak, P.; Ludwig, M.; Mathes, H. J.; Melissas, M.; Morello, C.; Oehlschläger, J.; Palmieri, N.; Pierog, T.; Rautenberg, J.; Rebel, H.; Roth, M.; Rühle, C.; Saftoiu, A.; Schieler, H.; Schmidt, A.; Schröder, F. G.; Sima, O.; Toma, G.; Trinchero, G. C.; Weindl, A.; Wochele, J.; Wommer, M.; Zabierowski, J.; Zensus, J. A.
2012-04-01
We observe a correlation between the slope of radio lateral distributions and the mean muon pseudorapidity of 59 individual cosmic-ray-air-shower events. The radio lateral distributions are measured with LOPES, a digital radio interferometer colocated with the multidetector-air-shower array KASCADE-Grande, which includes a muon-tracking detector. The result proves experimentally that radio measurements are sensitive to the longitudinal development of cosmic-ray air showers. This is one of the main prerequisites for using radio arrays for ultra-high-energy particle physics and astrophysics.
Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico
2017-04-01
Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.
Imaging of pannus formation in patients with mechanical heart valves.
Gündüz, Sabahattin; Özkan, Mehmet; Yesin, Mahmut
2015-11-26
Patient-prosthesis mismatch (PPM) should be recognized in patients with elevated transprosthetic gradients but without leaflet immobility, since the treatment strategy may differ in either etiology. However, thrombus and/or pannus formation should be excluded before a diagnosis of PPM is made. Particularly, pannus formation may not be diagnosed with 2-dimensional transesophageal echocardiography. Electrocardiographically gated 64-section multidetector computed tomography (MDCT) may be a promising tool in diagnosing or excluding pannus formation. Our report underlines the utility of MDCT in this regard and also emphasizes the importance of recognition of PPM as a differential diagnosis in such patients.
Imaging of pannus formation in patients with mechanical heart valves
Gündüz, Sabahattin; Özkan, Mehmet; Yesin, Mahmut
2015-01-01
Patient-prosthesis mismatch (PPM) should be recognized in patients with elevated transprosthetic gradients but without leaflet immobility, since the treatment strategy may differ in either etiology. However, thrombus and/or pannus formation should be excluded before a diagnosis of PPM is made. Particularly, pannus formation may not be diagnosed with 2-dimensional transesophageal echocardiography. Electrocardiographically gated 64-section multidetector computed tomography (MDCT) may be a promising tool in diagnosing or excluding pannus formation. Our report underlines the utility of MDCT in this regard and also emphasizes the importance of recognition of PPM as a differential diagnosis in such patients. PMID:26635931
The ROSPHERE γ-ray spectroscopy array
NASA Astrophysics Data System (ADS)
Bucurescu, D.; Căta-Danil, I.; Ciocan, G.; Costache, C.; Deleanu, D.; Dima, R.; Filipescu, D.; Florea, N.; Ghiţă, D. G.; Glodariu, T.; Ivaşcu, M.; Lică, R.; Mărginean, N.; Mărginean, R.; Mihai, C.; Negret, A.; Niţă, C. R.; Olăcel, A.; Pascu, S.; Sava, T.; Stroe, L.; Şerban, A.; Şuvăilă, R.; Toma, S.; Zamfir, N. V.; Căta-Danil, G.; Gheorghe, I.; Mitu, I. O.; Suliman, G.; Ur, C. A.; Braunroth, T.; Dewald, A.; Fransen, C.; Bruce, A. M.; Podolyák, Zs.; Regan, P. H.; Roberts, O. J.
2016-11-01
The ROmanian array for SPectroscopy in HEavy ion REactions (ROSPHERE) has been designed as a multi-detector setup dedicated to γ-ray spectroscopy studies at the Bucharest 9 MV Tandem accelerator. Consisting of up to 25 detectors (either Compton suppressed HPGe detectors or fast LaBr3(Ce) scintillator detectors) together with a state of the art plunger device, ROSPHERE is a powerful tool for lifetime measurements using the Recoil Distance Doppler Shift (RDDS) and the in-beam Fast Electronic Scintillation Timing (FEST) methods. The array's geometry, detectors, electronics and data acquisition system are described. Selected results from the first experimental campaigns are also presented.
Razek, Ahmed Abdel Khalek Abdel; Ezzat, Amany; Azmy, Emad; Tharwat, Nehal
2013-08-01
The authors evaluated the role of whole-body 64-slice multidetector computed tomography (WB-MDCT) in treatment planning for multiple myeloma. This was a prospective study of 28 consecutive patients with multiple myeloma (19 men, nine women; age range, 51-73 years; mean age, 60 years) who underwent WB-MDCT and conventional radiography (CR) of the skeleton. The images were interpreted for the presence of bony lesions, medullary lesions, fractures and extraosseous lesions. We evaluated any changes in treatment planning as a result of WB-MDCT findings. WB-MDCT was superior to CR for detecting bony lesions (p=0.001), especially of the spine (p=0.001) and thoracic cage (p=0.006). WB-MDCT upstaged 14 patients, with a significant difference in staging (p=0.002) between WB-MDCT and CR. Medullary involvement either focal (n=6) or diffuse (n=3) had a positive correlation with the overall score (r=0.790) and stage (r=0.618) of disease. Spine fractures were better detected at WB-MDCT (n=4) than at CR (n=2). Extraosseous soft tissue lesions (n=7) were detected only at WB-MDCT. Findings detected at the WB-MDCT led to changes in the patient's treatment plan in 39% of cases. Upstaging of seven patients (25%) altered the medical treatment plan, and four of 28 (14%) patients required additional radiotherapy (7%) and vertebroplasty (7%). We conclude that WB-MDCT has an impact on treatment planning and prognosis in patients with multiple myeloma, as it has high rate of detecting cortical and medullary bone lesions, spinal fracture and extraosseous lesions. This information may alter treatment planning in multiple myeloma due to disease upstaging and detection of spine fracture and extraosseous spinal lesions.
Lell, M M; May, M S; Brand, M; Eller, A; Buder, T; Hofmann, E; Uder, M; Wuest, W
2015-07-01
CT is the imaging technique of choice in the evaluation of midface trauma or inflammatory disease. We performed a systematic evaluation of scan protocols to optimize image quality and radiation exposure on third-generation dual-source CT. CT protocols with different tube voltage (70-150 kV), current (25-300 reference mAs), prefiltration, pitch value, and rotation time were systematically evaluated. All images were reconstructed with iterative reconstruction (Advanced Modeled Iterative Reconstruction, level 2). To individually compare results with otherwise identical factors, we obtained all scans on a frozen human head. Conebeam CT was performed for image quality and dose comparison with multidetector row CT. Delineation of important anatomic structures and incidental pathologic conditions in the cadaver head was evaluated. One hundred kilovolts with tin prefiltration demonstrated the best compromise between dose and image quality. The most dose-effective combination for trauma imaging was Sn100 kV/250 mAs (volume CT dose index, 2.02 mGy), and for preoperative sinus surgery planning, Sn100 kV/150 mAs (volume CT dose index, 1.22 mGy). "Sn" indicates an additional prefiltration of the x-ray beam with a tin filter to constrict the energy spectrum. Exclusion of sinonasal disease was possible with even a lower dose by using Sn100 kV/25 mAs (volume CT dose index, 0.2 mGy). High image quality at very low dose levels can be achieved by using a Sn100-kV protocol with iterative reconstruction. The effective dose is comparable with that of conventional radiography, and the high image quality at even lower radiation exposure favors multidetector row CT over conebeam CT. © 2015 by American Journal of Neuroradiology.
Tack, Denis; Jahnen, Andreas; Kohler, Sarah; Harpes, Nico; De Maertelaer, Viviane; Back, Carlo; Gevenois, Pierre Alain
2014-01-01
To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. • External support through clinical audit may optimise default parameters of routine CT. • Reduction of 75th percentiles used as reference diagnostic levels is 18-75 %. • The effect of this audit is sustainable over time. • Dose savings through optimisation can be added to those achievable through CT.
Markers of Vascular Perturbation Correlate with Airway Structural Change in Asthma
Kruger, Stanley J.; Schiebler, Mark L.; Evans, Michael D.; Sorkness, Ronald L.; Denlinger, Loren C.; Busse, William W.; Jarjour, Nizar N.; Montgomery, Robert R.; Mosher, Deane F.; Fain, Sean B.
2013-01-01
Rationale: Air trapping and ventilation defects on imaging are characteristics of asthma. Airway wall thickening occurs in asthma and is associated with increased bronchial vascularity and vascular permeability. Vascular endothelial cell products have not been explored as a surrogate to mark structural airway changes in asthma. Objectives: Determine whether reporters of vascular endothelial cell perturbation correlate with airway imaging metrics in patients with asthma of varying severity. Methods: Plasma from Severe Asthma Research Program subjects was analyzed by ELISAs for soluble von Willebrand factor mature protein (VWF:Ag) and propeptide (VWFpp), P-selectin, and platelet factor 4. Additional subjects were analyzed over 48 hours after whole-lung antigen challenge. We calculated ventilation defect volume by hyperpolarized helium-3 magnetic resonance imaging and areas of low signal density by multidetector computed tomography (less than −856 Hounsfield units [HU] at functional residual capacity and −950 HU at total lung capacity [TLC]). Measurements and Main Results: VWFpp and VWFpp/Ag ratio correlated with and predicted greater percentage defect volume on hyperpolarized helium-3 magnetic resonance imaging. P-selectin correlated with and predicted greater area of low density on chest multidetector computed tomography less than −950 HU at TLC. Platelet factor 4 did not correlate. Following whole-lung antigen challenge, variation in VWFpp, VWFpp/Ag, and P-selectin among time-points was less than that among subjects, indicating stability and repeatability of the measurements. Conclusions: Plasma VWFpp and P-selectin may be useful as surrogates of functional and structural defects that are evident on imaging. The results raise important questions about why VWFpp and P-selectin are associated specifically with different imaging abnormalities. PMID:23855693
Ianniello, Stefania; Di Giacomo, Vincenza; Sessa, Barbara; Miele, Vittorio
2014-09-01
Combined clinical examination and supine chest radiography have shown low accuracy in the assessment of pneumothorax in unstable patients with major chest trauma during the primary survey in the emergency room. The aim of our study was to evaluate the diagnostic accuracy of extended-focused assessment with sonography in trauma (e-FAST), in the diagnosis of pneumothorax, compared with the results of multidetector computed tomography (MDCT) and of invasive interventions (thoracostomy tube placement). This was a retrospective case series involving 368 consecutive unstable adult patients (273 men and 95 women; average age, 25 years; range, 16-68 years) admitted to our hospital's emergency department between January 2011 and December 2012 for major trauma (Injury Severity Score ≥ 15). We evaluated the accuracy of thoracic ultrasound in the detection of pneumothorax compared with the results of MDCT and invasive interventions (thoracostomy tube placement). Institutional review board approval was obtained prior to commencement of this study. Among the 736 lung fields included in the study, 87 pneumothoraces were detected with thoracic CT scans (23.6%). e-FAST detected 67/87 and missed 20 pneumothoraces (17 mild, 3 moderate). The diagnostic performance of ultrasound was: sensitivity 77% (74% in 2011 and 80% in 2012), specificity 99.8%, positive predictive value 98.5%, negative predictive value 97%, accuracy 97.2% (67 true positive; 668 true negative; 1 false positive; 20 false negative); 17 missed mild pneumothoraces were not immediately life-threatening (thickness less than 5 mm). Thoracic ultrasound (e-FAST) is a rapid and accurate first-line, bedside diagnostic modality for the diagnosis of pneumothorax in unstable patients with major chest trauma during the primary survey in the emergency room.
Clarkson, Wesley A; Restrepo, Carlos Santiago; Bauch, Terry D; Rubal, Bernard J
2009-01-01
This study examines the effects of intravenous infusion of adenosine and sublingual nitroglycerin on coronary angiograms obtained by current-generation multidetector computed tomography. We assessed coronary vasodilation at baseline and after intravenous adenosine (140 µg/kg/min) or sublingual nitroglycerin spray (800 µg) in 7 female swine (weight, 40.9 ± 1.4 kg) by using electrocardiogram-gated coronary angiography with a 64-detector scanner (rotation time, 400 ms; 120kV; 400 mA) and intravenous contrast (300 mg/mL iohexol, 4.5 mL/s, 2 mL/kg). Cross-sectional areas of segments in the left anterior descending, circumflex, and right coronary arteries were evaluated in oblique orthogonal views. Images were acquired at an average heart rate of 73 ± 11 beats per minute. Changes in aortic pressure were not significant with nitroglycerin but decreased (approximately 10%) with adenosine. Of the 76 segments analyzed (baseline range, 2 to 39 mm2), 1 distal segment could not be assessed after adenosine. Segment cross-sectional area increased by 11.3% with nitroglycerin but decreased by 9.6% during adenosine infusion. The results of the present study are consistent with the practice of using sublingual nitroglycerin to enhance visualization of epicardial vessels and suggest that intravenous adenosine may hinder coronary artery visualization. This study is the first repeated-measures electrocardiogram-gated CT evaluation to use the same imaging technology to assess changes in coronary cross-sectional area before and after treatment with a vasodilator. The nitroglycerin-associated changes in our swine model were modest in comparison with previously reported human studies. PMID:20034433
Farghadani, Maryam; Momeni, Mohammad; Hekmatnia, Ali; Momeni, Fateme; Baradaran Mahdavi, Mohammad Mehdi
2016-01-01
The celiac axis, superior mesenteric artery (SMA), and hepatic artery are the most important branches of abdominal aorta due to their vascularization field. The aim of our study was to evaluate the prevalence of different anatomical variation of celiac axis, SMA, hepatic artery, and its branches with multidetector computed tomography (MDCT) angiography of upper abdomen arteries. MDCT of 607 kidney donor and traumatic patients that referred to MDCT unit at Al Zahra Hospital in Isfahan from 2012 to 2015 were retrospectively evaluated. We excluded patients with history of abdominal vascular surgery and hepatic or pancreatic surgery. Computed tomography images of the patient were obtained with 64-row MDCT scanner and anatomical variations were analyzed. Three hundred and eighty-eight (63.9%) of the 607 patients had classic arterial anatomy and 219 (36.1%) patients had variant types. The most common type of variation was the origin of the right hepatic artery (RHA) from SMA (9.6%), and the next common variation was the origin of the left hepatic artery (LHA) from the left gastric artery (6.9%). Variations in the origin of the common hepatic artery (CHA) were seen in 16 (2.6%) patients. Buhler arc was identified in two patients. The RHA originated from the celiac axis in 11 (1.8%) patients and from the aorta in 8 (1.3%) patients. Trifurcation of CHA into gastroduodenal artery, RHA, and LHA was detected in 11 (1.8%) patients. The results of the present study showed that anatomical variation occurs in a high percentage of patients. Detection of these variations can guide surgical and radiological interventional planning.
Koyoshi, Rie; Shiga, Yuhei; Idemoto, Yoshiaki; Ueda, Yoko; Tashiro, Kohei; Kuwano, Takashi; Kitajima, Ken; Fujimi, Kanta; Kawamura, Akira; Ogawa, Masahiro; Miura, Shin-Ichiro
2018-01-01
We evaluated the safety of a bolus injection of landiolol hydrochloride, an ultrashort-acting β1-selective antagonist, as a premedication prior to multidetector-row computed tomography coronary angiography (CTA). The subjects consisted of 176 patients (M/F = 64:112, 67 ± 11 years) who had heart rate (HR) at rest ≥ 70 beats/min (bpm) and underwent CTA. Systolic/diastolic blood pressure (SBP/DBP) and HR were measured before and after the administration of landiolol. SBP/DBP and HR upon entry to the CT room were 136 ± 17/80 ± 11 mm Hg and 83 ± 10 bpm, respectively. HR was significantly reduced at the time of CTA scan (62 ± 7 bpm). Next, we divided the patients into three groups according to HR upon entry to the CT room: 70 - 79 bpm (n = 76), 80 - 89 bpm (n = 60) and ≥ 90 bpm (n = 40). HR at the time of CTA scan was significantly lower than that upon entry to the CT room in all three groups: 70 - 79 bpm (74 ± 3 bpm upon entry to the CT room to 61 ± 6 bpm at the time of CAT scan), 80 - 89 bpm (84 ± 3 to 63 ± 7 bpm) and ≥ 90 bpm (98 ± 6 to 65 ± 7 bpm). Although SBP/DBP was significantly decreased after the CTA scan (123 ± 18/72 ± 12 mm Hg), landiolol had no severe adverse events throughout CTA. In conclusion, a bolus injection of landiolol reduced HR by about 20 bpm without any severe adverse effects. Thus, a bolus injection of landiolol hydrochloride may be a suitable pretreatment for controlling HR in CTA.
Leyhe, Johanna Rosemarie; Tsogkas, Ioannis; Hesse, Amélie Carolina; Behme, Daniel; Schregel, Katharina; Papageorgiou, Ismini; Liman, Jan; Knauth, Michael; Psychogios, Marios-Nikos
2017-12-01
Flat detector CT (FDCT) has been used as a peri-interventional diagnostic tool in numerous studies with mixed results regarding image quality and detection of intracranial lesions. We compared the diagnostic aspects of the latest generation FDCT with standard multidetector CT (MDCT). 102 patients were included in our retrospective study. All patients had undergone interventional procedures. FDCT was acquired peri-interventionally and compared with postinterventional MDCT regarding depiction of ventricular/subarachnoidal spaces, detection of intracranial hemorrhage, and delineation of ischemic lesions using an ordinal scale. Ischemic lesions were quantified with the Alberta Stroke Program Early CT Scale (ASPECTS) on both examinations. Two neuroradiologists with varying grades of experience and a medical student scored the anonymized images separately, blinded to the clinical history. The two methods were of equal diagnostic value regarding evaluation of the ventricular system and the subarachnoidal spaces. Subarachnoidal, intraventricular, and parenchymal hemorrhages were detected with a sensitivity of 95%, 97%, and 100% and specificity of 97%, 100%, and 99%, respectively, using FDCT. Gray-white differentiation was feasible in the majority of FDCT scans, and ischemic lesions were detected with a sensitivity of 71% on FDCT, compared with MDCT scans. The mean difference in ASPECTS values on FDCT and MDCT was 0.5 points (95% CI 0.12 to 0.88). The latest generation of FDCT is a reliable and accurate tool for the detection of intracranial hemorrhage. Gray-white differentiation is feasible in the supratentorial region. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
NASA Astrophysics Data System (ADS)
Ichihara, Takashi; George, Richard T.; Silva, Caterina; Lima, Joao A. C.; Lardo, Albert C.
2011-02-01
The purpose of this study was to develop a quantitative method for myocardial blood flow (MBF) measurement that can be used to derive accurate myocardial perfusion measurements from dynamic multidetector computed tomography (MDCT) images by using a compartment model for calculating the first-order transfer constant (K1) with correction for the capillary transit extraction fraction (E). Six canine models of left anterior descending (LAD) artery stenosis were prepared and underwent first-pass contrast-enhanced MDCT perfusion imaging during adenosine infusion (0.14-0.21 mg/kg/min). K1 , which is the first-order transfer constant from left ventricular (LV) blood to myocardium, was measured using the Patlak plot method applied to time-attenuation curve data of the LV blood pool and myocardium. The results were compared against microsphere MBF measurements, and the extraction fraction of contrast agent was calculated. K1 is related to the regional MBF as K1=EF, E=(1-exp(-PS/F)), where PS is the permeability-surface area product and F is myocardial flow. Based on the above relationship, a look-up table from K1 to MBF can be generated and Patlak plot-derived K1 values can be converted to the calculated MBF. The calculated MBF and microsphere MBF showed a strong linear association. The extraction fraction in dogs as a function of flow (F) was E=(1-exp(-(0.2532F+0.7871)/F)) . Regional MBF can be measured accurately using the Patlak plot method based on a compartment model and look-up table with extraction fraction correction from K1 to MBF.
Sørgaard, Mathias; Linde, Jesper J; Hove, Jens D; Petersen, Jan R; Jørgensen, Tem B S; Abdulla, Jawdat; Heitmann, Merete; Kragelund, Charlotte; Hansen, Thomas Fritz; Udholm, Patricia M; Pihl, Christian; Kühl, J Tobias; Engstrøm, Thomas; Jensen, Jan Skov; Høfsten, Dan E; Kelbæk, Henning; Kofoed, Klaus F
2016-09-01
Patients admitted with chest pain are a diagnostic challenge because the majority does not have coronary artery disease (CAD). Assessment of CAD with coronary computed tomography angiography (CCTA) is safe, cost-effective, and accurate, albeit with a modest specificity. Stress myocardial computed tomography perfusion (CTP) has been shown to increase the specificity when added to CCTA, without lowering the sensitivity. This article describes the design of a randomized controlled trial, CATCH-2, comparing a clinical diagnostic management strategy of CCTA alone against CCTA in combination with CTP. Patients with acute-onset chest pain older than 50 years and with at least one cardiovascular risk factor for CAD are being prospectively enrolled to this study from 6 different clinical sites since October 2013. A total of 600 patients will be included. Patients are randomized 1:1 to clinical management based on CCTA or on CCTA in combination with CTP, determining the need for further testing with invasive coronary angiography including measurement of the fractional flow reserve in vessels with coronary artery lesions. Patients are scanned with a 320-row multidetector computed tomography scanner. Decisions to revascularize the patients are taken by the invasive cardiologist independently of the study allocation. The primary end point is the frequency of revascularization. Secondary end points of clinical outcome are also recorded. The CATCH-2 will determine whether CCTA in combination with CTP is diagnostically superior to CCTA alone in the management of patients with acute-onset chest pain. Copyright © 2015 Elsevier Inc. All rights reserved.
Gooley, Robert P; Cameron, James D; Soon, Jennifer; Loi, Duncan; Chitale, Gauri; Syeda, Rifath; Meredith, Ian T
2015-09-01
Multidetector computed tomographic (MDCT) assessment of the aortoventricular interface has gained increased importance with the advent of minimally invasive treatment modalities for aortic and mitral valve disease. This has included a standardised technique of identifying a plane through the nadir of each coronary cusp, the basal plane, and taking further measurements in relation to this plane. Despite this there is no published data defining normal ranges for these aortoventricular metrics in a healthy cohort. This study seeks to quantify normative ranges for MDCT derived aortoventricular dimensions and evaluate baseline demographic and anthropomorphic associates of these measurements in a normal cohort. 250 consecutive patients undergoing MDCT coronary angiography were included. Aortoventricular dimensions at multiple levels of the aortoventricular interface were assessed and normative ranges quantified. Multivariate linear regression was performed to identify baseline predictors of each metric. The mean age was 59±12 years. The basal plane was eccentric (EI=0.22±0.06) while the left ventricular outflow tract was more eccentric (EI=0.32±0.06), with no correlation to gender, age or hypertension. Male gender, height and body mass index were consistent independent predictors of larger aortoventricular dimensions at all anatomical levels, while age was predictive of supra-annular measurements. Male gender, height and BMI are independent predictors of all aortoventricular dimensions while age predicts only supra-annular dimensions. Use of defined metrics such as the basal plane and formation of normative ranges for these metrics allows reference for clinical reporting and for future research studies by using a standardised measurement technique. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Türkvatan, Aysel; Akinci, Serkan; Yildiz, Sener; Olçer, Tülay; Cumhur, Turhan
2009-04-01
Currently, multidetector computed tomographic (MDCT) angiography has become a noninvasive alternative imaging modality to catheter renal angiography for the evaluation of renal vascular anatomy in living renal donors. In this study, we investigated the diagnostic accuracy of 16-slice MDCT in the preoperative assessment of living renal donors. Fifty-nine consecutive living renal donors (32 men, 27 women) underwent MDCT angiography followed by open donor nephrectomy. All MDCT studies were performed by using a 16-slice MDCT scanner with the same protocol consisting of arterial and nephrographic phases followed by conventional abdominal radiography. The MDCT images were assessed retrospectively for the number and branching pattern of the renal arteries and for the number and presence of major or minor variants of the renal veins. The results were compared with open surgical results. The sensitivity and specificity of MDCT for the detection of anatomic variants of renal arteries including the accessory arteries (n = 9), early arterial branching (n = 7) and major renal venous anomalies including the accessory renal veins (n = 3), late venous confluence (n = 4), circumaortic (n = 2) or retroaortic (n = 3) left renal veins were 100%. However, the sensitivity for identification of minor venous variants was 79%. All of three ureteral duplications were correctly identified at excretory phase conventional abdominal radiography. Sixteen-slice MDCT is highly accurate for the identification of anatomic variants of renal arteries and veins. Dual-phase MDCT angiography including arterial and nephrographic phases followed by conventional abdominal radiography enables complete assessment of renal donors without significant increase of radiation dose. However, the evaluation of minor venous variants may be problematic because of their small diameters and poor opacification.
Chaosuwannakit, N; Makarawate, P
2018-01-01
Primary evaluation of patients with pulmonary atresia with ventricular septal defect (PA-VSD) traditionally relies upon echocardiography and conventional cardiac angiography (CCA). Cardiac angiography is considered the gold standard for delineation of anatomy in children with PA-VSD. Data comparing CCA and dual-source multidetector-row computed tomography angiography (MDCT) in PA-VSD patients is limited. The objective of this study was to test the hypothesis that MDCT is equivalent to CCA for anatomic delineation in these patients. Twenty-eight patients with PA-VSD underwent CCA and MDCT in close proximity to each other without interval therapy. A retrospective review of these 28 patients was performed. All MDCT data of pulmonary artery morphology, major aortopulmonary collateral arteries (MAPCAs) and type of blood supply (dual vs. single supply) were evaluated by blinded experts and results were compared with CCA. Twenty-eight patients had adequate size right and left pulmonary arteries (21 confluent and 7 non-confluent). Seven patients had complete absence of native pulmonary artery and 3 patients had stenosis of distal branches of pulmonary arteries; all had MAPCAs from descending thoracic aorta and/or subclavian arteries. Sensitivity, specificity, positive and negative predictive value of MDCT for detecting confluent of pulmonary arteries, absence of native pulmonary artery and stenosis of pulmonary arteries were all 100%. Moreover, accuracy of detecting MAPCAs was excellent. These results suggest that MDCT and CCA are equivalent in their ability to delineate pulmonary artery anatomy and MAPCAs. Dual source MDCT provides high diagnostic accuracy in evaluation of pulmonary blood supply in patients with PA-VSD and allows precise characterisation of the condition of pulmonary arteries and MAPCAs which is of paramount importance in managing patients with PA-VSD. (Folia Morphol 2018; 77, 1: 116-122).
Fan, L; Liu, S-Y; Li, Q-C; Yu, H; Xiao, X-S
2012-01-01
Objective To evaluate different features between benign and malignant pulmonary focal ground-glass opacity (fGGO) on multidetector CT (MDCT). Methods 82 pathologically or clinically confirmed fGGOs were retrospectively analysed with regard to demographic data, lesion size and location, attenuation value and MDCT features including shape, margin, interface, internal characteristics and adjacent structure. Differences between benign and malignant fGGOs were analysed using a χ2 test, Fisher's exact test or Mann–Whitney U-test. Morphological characteristics were analysed by binary logistic regression analysis to estimate the likelihood of malignancy. Results There were 21 benign and 61 malignant lesions. No statistical differences were found between benign and malignant fGGOs in terms of demographic data, size, location and attenuation value. The frequency of lobulation (p=0.000), spiculation (p=0.008), spine-like process (p=0.004), well-defined but coarse interface (p=0.000), bronchus cut-off (p=0.003), other air-containing space (p=0.000), pleural indentation (p=0.000) and vascular convergence (p=0.006) was significantly higher in malignant fGGOs than that in benign fGGOs. Binary logistic regression analysis showed that lobulation, interface and pleural indentation were important indicators for malignant diagnosis of fGGO, with the corresponding odds ratios of 8.122, 3.139 and 9.076, respectively. In addition, a well-defined but coarse interface was the most important indicator of malignancy among all interface types. With all three important indicators considered, the diagnostic sensitivity, specificity and accuracy were 93.4%, 66.7% and 86.6%, respectively. Conclusion An fGGO with lobulation, a well-defined but coarse interface and pleural indentation gives a greater than average likelihood of being malignant. PMID:22128130
Direk, Filiz; Uysal, Ismihan Ilknur; Kivrak, Ali Sami; Fazliogullari, Zeliha; Unver Dogan, Nadire; Karabulut, Ahmet Kagan
2018-03-01
The mental foramen and lingual vascular canals are related to vessels and nerves in the mandibular body. The aim of the present study was to determine the number and location of these structures and to make measurements of them. The archived Multidetector Computed Tomography images of 100 adult (15- to 70-year-old) patients were evaluated retrospectively. The diameters of the mental foramens and their distances from the front, back, upper and lower reference points were measured. The distribution of mental foramens with respect to the teeth was also researched. The presence of lingual vascular canals, and the number of median and lateral canals was determined, and the length of the median lingual vascular canals measured. All measurement parameters were analyzed by gender, side and age group. Eleven patients demonstrated a total of 15 accessory mental foramen. Median lingual vascular canals were observed in 100% of cases, with lateral lingual vascular canals determined in 32%. Significant differences were observed in the results of different gender groups (P < 0.05); in contrast, no significant difference was observed related with age or side. Accessory mental foramen was determined mostly in males, and unilaterally on the right side; also, the distances of mental foramen, except the distance from the back border of the mandible (P < 0.05), were found to be higher, bilaterally, in males. Variation of mental foramen, as well as the presence, position and size of lingual vascular canals can be clearly investigated by multidetector computed tomography. A preoperative knowledge of the positions of neurovascular and bone structures is very important for preventing complications that may occur during or after operations.
Liszewski, Mark C; Sahni, V Anik; Shyn, Paul B; Friedman, Sonia; Hornick, Jason L; Erturk, Sukru M; Mortele, Koenraad J
2012-01-01
To describe the multidetector-row computed tomography enterographic (MD-CTE) features of the ileal-anal pouch after ileal pouch anal anastomosis (IPAA) surgery and correlate them with pouch endoscopy and histopathologic findings. All MD-CTE examinations performed on patients who underwent IPAA from July 1, 2005 to December 1, 2010 (n = 35; 16 [45.7%] men; mean age, 37.7 years; age range, 22-72 years) were retrospectively evaluated in consensus by 2 radiologists. All studies were evaluated for the presence of multiple imaging features. Two radiographic scores were then calculated: a total radiographic score and a radiographic active inflammation score. In patients who underwent MD-CTE, pouch endoscopy, and biopsy within 30 days (n = 13), both scores were correlated with findings on pouch endoscopy and histopathology. Of the 35 patients, 33 (94%) had at least one MD-CTE finding of active or chronic pouch inflammation and 27 patients (77%) had at least one MD-CTE finding of active pouch inflammation. Of the 13 patients who underwent endoscopy and biopsy, the total radiographic score demonstrated a strong positive correlation with endoscopic score (r = 0.81; P = 0.001) and a moderate positive correlation with histopathologic score (r = 0.56; P = 0.047). The radiographic active inflammation score demonstrated a strong positive correlation with endoscopic score (r = 0.83; P = 0.0004), but only a weak nonsignificant positive correlation with histopathologic score (r = 0.492, P = 0.087). In patients who had IPAA surgery, findings on MD-CTE correlate positively with findings on pouch endoscopy and histopathology and are sensitive measures for pouch inflammation with high positive predictive value. Thus, MD-CTE can be a useful noninvasive test in the early evaluation of symptomatic patients.
Podlesnikar, Tomaz; Prihadi, Edgard A; van Rosendael, Philippe J; Vollema, E Mara; van der Kley, Frank; de Weger, Arend; Ajmone Marsan, Nina; Naji, Franjo; Fras, Zlatko; Bax, Jeroen J; Delgado, Victoria
2018-01-01
Accurate aortic annulus sizing is key for selection of appropriate transcatheter aortic valve implantation (TAVI) prosthesis size. The present study compared novel automated 3-dimensional (3D) transesophageal echocardiography (TEE) software and multidetector row computed tomography (MDCT) for aortic annulus sizing and investigated the influence of the quantity of aortic valve calcium (AVC) on the selection of TAVI prosthesis size. A total of 83 patients with severe aortic stenosis undergoing TAVI were evaluated. Maximal and minimal aortic annulus diameter, perimeter, and area were measured. AVC was assessed with computed tomography. The low and high AVC burden groups were defined according to the median AVC score. Overall, 3D TEE measurements slightly underestimated the aortic annulus dimensions as compared with MDCT (mean differences between maximum, minimum diameter, perimeter, and area: -1.7 mm, 0.5 mm, -2.7 mm, and -13 mm 2 , respectively). The agreement between 3D TEE and MDCT on aortic annulus dimensions was superior among patients with low AVC burden (<3,025 arbitrary units) compared with patients with high AVC burden (≥3,025 arbitrary units). The interobserver variability was excellent for both methods. 3D TEE and MDCT led to the same prosthesis size selection in 88%, 95%, and 81% of patients in the total population, the low, and the high AVC burden group, respectively. In conclusion, the novel automated 3D TEE imaging software allows accurate and highly reproducible measurements of the aortic annulus dimensions and shows excellent agreement with MDCT to determine the TAVI prosthesis size, particularly in patients with low AVC burden. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
Gaudio, Carlo; Mirabelli, Francesca; Pelliccia, Francesco; Francone, Marco; Tanzilli, Gaetano; Di Michele, Sara; Leonetti, Stefania; De Vincentis, Giuseppe; Carbone, Iacopo; Mangieri, Enrico; Catalano, Carlo; Passariello, Roberto
2009-07-10
The 64-slice multidetector-row computed tomography (MDCT) is an accurate noninvasive technique for assessing the degree of luminal narrowing in coronary arteries of patients with chronic ischemic disease. Aim of this study was to determine the value of MDCT in comparison to invasive coronary angiography (ICA) for detecting the presence and extent of coronary atherosclerotic plaques in a population of asymptomatic, hypertensive patients considered to be at high risk for cardiovascular events. We studied 67 asymptomatic, hypertensive patients at high-risk (Euro Score >5%). All patients had negative or nondiagnostic findings at exercise stress testing and therefore underwent both MDCT and ICA. In the per-patient analysis, MDCT correctly identified 16/17 (94%) patients with significant coronary artery disease involving at least 1 vessel and 48/50 (96%) normal subjects. In the per-segment analysis, MDCT correctly detected 21/22 (95%) coronary segments with a stenosis >or=50% and 856/868 (98%) normal segments, with a high negative predictivity of normal scans (100%). There was a good concordance between MDCT and ICA, with a high Pearson correlation coefficient between the coronary narrowings with the two techniques (r=0.84, p<0.01). Mean coronary calcium score was higher for the 17 patients with significant coronary artery disease on ICA than in the 50 patients without (422+/-223 HU vs 72+/-21 HU p<0.001). The ROC curves identified 160 as the best calcium volumetric score cut-off value able to identify >or=1 significant coronary stenosis with sensitivity 88% and specificity 85%. MDCT is an excellent noninvasive technique for early identification of significant coronary stenoses in high risk asymptomatic hypertensive patients and might provide unique information for the screening of this broad population.
Hirose, Tomohiro; Nitta, Norihisa; Shiraishi, Junji; Nagatani, Yukihiro; Takahashi, Masashi; Murata, Kiyoshi
2008-12-01
The aim of this study was to evaluate the usefulness of computer-aided diagnosis (CAD) software for the detection of lung nodules on multidetector-row computed tomography (MDCT) in terms of improvement in radiologists' diagnostic accuracy in detecting lung nodules, using jackknife free-response receiver-operating characteristic (JAFROC) analysis. Twenty-one patients (6 without and 15 with lung nodules) were selected randomly from 120 consecutive thoracic computed tomographic examinations. The gold standard for the presence or absence of nodules in the observer study was determined by consensus of two radiologists. Six expert radiologists participated in a free-response receiver operating characteristic study for the detection of lung nodules on MDCT, in which cases were interpreted first without and then with the output of CAD software. Radiologists were asked to indicate the locations of lung nodule candidates on the monitor with their confidence ratings for the presence of lung nodules. The performance of the CAD software indicated that the sensitivity in detecting lung nodules was 71.4%, with 0.95 false-positive results per case. When radiologists used the CAD software, the average sensitivity improved from 39.5% to 81.0%, with an increase in the average number of false-positive results from 0.14 to 0.89 per case. The average figure-of-merit values for the six radiologists were 0.390 without and 0.845 with the output of the CAD software, and there was a statistically significant difference (P < .0001) using the JAFROC analysis. The CAD software for the detection of lung nodules on MDCT has the potential to assist radiologists by increasing their accuracy.
Baskerville, Jerry Ray; Herrick, John
2012-02-01
This study focuses on clinically assigned prospective estimated pretest probability and pretest perception of legal risk as independent variables in the ordering of multidetector computed tomographic (MDCT) head scans. Our primary aim is to measure the association between pretest probability of a significant finding and pretest perception of legal risk. Secondarily, we measure the percentage of MDCT scans that physicians would not order if there was no legal risk. This study is a prospective, cross-sectional, descriptive analysis of patients 18 years and older for whom emergency medicine physicians ordered a head MDCT. We collected a sample of 138 patients subjected to head MDCT scans. The prevalence of a significant finding in our population was 6%, yet the pretest probability expectation of a significant finding was 33%. The legal risk presumed was even more dramatic at 54%. These data support the hypothesis that physicians presume the legal risk to be significantly higher than the risk of a significant finding. A total of 21% or 15% patients (95% confidence interval, ±5.9%) would not have been subjected to MDCT if there was no legal risk. Physicians overestimated the probability that the computed tomographic scan would yield a significant result and indicated an even greater perceived medicolegal risk if the scan was not obtained. Physician test-ordering behavior is complex, and our study queries pertinent aspects of MDCT testing. The magnification of legal risk vs the pretest probability of a significant finding is demonstrated. Physicians significantly overestimated pretest probability of a significant finding on head MDCT scans and presumed legal risk. Copyright © 2012 Elsevier Inc. All rights reserved.
Stratis, Andreas; Zhang, Guozhi; Lopez-Rendon, Xochitl; Politis, Constantinus; Hermans, Robert; Jacobs, Reinhilde; Bogaerts, Ria; Shaheen, Eman; Bosmans, Hilde
2017-09-01
To calculate organ doses and estimate the effective dose for justification purposes in patients undergoing orthognathic treatment planning purposes and temporal bone imaging in dental cone beam CT (CBCT) and Multidetector CT (MDCT) scanners. The radiation dose to the ICRP reference male voxel phantom was calculated for dedicated orthognathic treatment planning acquisitions via Monte Carlo simulations in two dental CBCT scanners, Promax 3D Max (Planmeca, FI) and NewTom VGi evo (QR s.r.l, IT) and in Somatom Definition Flash (Siemens, DE) MDCT scanner. For temporal bone imaging, radiation doses were calculated via MC simulations for a CBCT protocol in NewTom 5G (QR s.r.l, IT) and with the use of a software tool (CT-expo) for Somatom Force (Siemens, DE). All procedures had been optimized at the acceptance tests of the devices. For orthognathic protocols, dental CBCT scanners deliver lower doses compared to MDCT scanners. The estimated effective dose (ED) was 0.32mSv for a normal resolution operation mode in Promax 3D Max, 0.27mSv in VGi-evo and 1.18mSv in the Somatom Definition Flash. For temporal bone protocols, the Somatom Force resulted in an estimated ED of 0.28mSv while for NewTom 5G the ED was 0.31 and 0.22mSv for monolateral and bilateral imaging respectively. Two clinical exams which are carried out with both a CBCT or a MDCT scanner were compared in terms of radiation dose. Dental CBCT scanners deliver lower doses for orthognathic patients whereas for temporal bone procedures the doses were similar. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Chu, Zhi-gang; Yang, Zhi-gang; Dong, Zhi-hui; Chen, Tian-wu; Zhu, Zhi-yu; Deng, Wen; Xiao, Jia-he
2011-10-01
In a massive earthquake, cranio-maxillofacial trauma was common. The present study was to determine the features of cranio-maxillofacial trauma sustained in the massive Sichuan earthquake by multi-detector row computed tomography (MDCT). The study included 221 consecutive patients (123 males and 98 females; age range, 1-83 years; median age, 35 years) with cranio-maxillofacial trauma in the Sichuan earthquake, who underwent cranio-maxillofacial MDCT scans. The image data were retrospectively reviewed focusing on the injuries of the cranio-maxillofacial soft tissue, facial bones and cranium. All patients had soft tissue injuries frequently with foreign bodies. Ninety-seven (43.9%) patients had fractures (1.5 involved sites per patient, range from 1 to 8) including single cranial fractures in 36 (37.1%) cases, single maxillofacial fractures were seen in 48 (49.5%) and cranio-maxillofacial fractures in 13 (13.4%). Single bone fracture was more common than multiple bone fractures (p<0.05). Nasal, ethmoid bones and the orbits were the most commonly involved sites of the craniofacial region. Thirty-eight (17.2%) patients had intracranial injuries, the commonest being subarachnoid haemorrhage and the commonest sites were the temporal and frontal regions. Coexisting intracranial injuries were more common in patients with cranial fractures than in patients with maxillofacial fractures (p<0.05). Our results indicate that the cranio-maxillofacial trauma arising from the massive Sichuan earthquake had some characteristic features, and a significant number of individuals had the potential for combined cranial and maxillofacial injuries, successful management of which required a multidisciplinary approach. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.
2013-01-01
Introduction Peptic ulcer disease is still the major cause of gastrointestinal perforation despite major improvements in both diagnostic and therapeutic strategies. While the diagnosis of a perforated ulcer is straightforward in typical cases, its clinical onset may be subtle because of comorbidities and/or concurrent therapies. Case presentation We report the case of a 53-year-old Caucasian man with a history of chronic myeloid leukemia on maintenance therapy (100mg/day) with imatinib who was found to have a subphrenic abscess resulting from a perforated duodenal ulcer that had been clinically overlooked. Our patient was febrile (38.5°C) with abdominal tenderness and hypoactive bowel sounds. On the abdominal plain X-ray films, a right subphrenic abscess could be seen. On contrast-enhanced multi-detector computed tomography, a huge air-fluid collection extending from the subphrenic to the subhepatic anterior space was observed. After oral administration of 500cm3 of 3 percent diluted diatrizoate meglumine, an extraluminal leakage of the water-soluble iodinated contrast media could then be appreciated as a result of a perforated duodenal ulcer. During surgery, the abscess was drained and extensive adhesiolysis had to be performed to expose the duodenal bulb where the ulcer was first identified by methylene blue administration and then sutured. Conclusions While subphrenic abscesses are well known complications of perforated gastric or duodenal ulcers, they have nowadays become rare thanks to advances in both diagnostic and therapeutic strategies for peptic ulcer disease. However, when peptic ulcer disease is not clinically suspected, the contribution of imaging may be substantial. PMID:24215711
Baskerville, J R; Chang, J H; Viator, M; Rutledge, W; Miryala, R; Duval, K E; Nishino, T K
2009-01-01
To determine the iatrogenic absorbed dosage of radiation of the patient in milligray (mGy) computerised tomography dose index volume (CTDIvol) when tested with multidetector computerised tomography (MDCT) in the emergency department (ED) setting and calculate the absorbed dosage of radiation per clinically actionable result and emergently treatable finding (ETF). The University of Texas Medical Branch (UTMB) ED located in Galveston, Texas, USA, is a level 1 trauma and tertiary referral centre treating 70,000 patients per annum. A retrospective cross-sectional data analysis of 770 emergency patients investigated by MDCT in July 2007. The presence of actionable results and ETF were determined by chart review. A total of 5320 emergency patients was treated in the UTMB ED in July 2007. This included 4508 medical and 812 trauma patients. A total of 1094 MDCT studies was performed, of which complete data were available on 1046. A total of 770 patients was investigated by MDCT, representing 14.47% of all emergency patients. This included 33.99% of trauma patients and 10.96% of medical patients. Actionable results were found in 341 studies and ETF in 105 studies. The mean radiation was 163.27 and 530.23 mGy CTDIvol for actionable results and ETF, respectively, for all studies. The mean radiation was 53.27 and 106.36 mGy CTDIvol for medical and trauma patients, respectively. The absorbed dosage of radiation of patients investigated by MDCT is clinically significant. The actionable results and ETF in our study demonstrate considerable opportunity for improvement in the utilisation of this technology by physicians.
Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Abe, Takayuki; Kuribayashi, Sachio; Ogawa, Kenji
2013-08-01
To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA-950) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P < 0.0001) of tomosynthesis than radiography for the detection of pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA-950. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA-950. • Tomosynthesis showed significantly better diagnostic performance for pulmonary emphysema than radiography. • Interobserver agreement for tomosynthesis was significantly higher than that for radiography. • Sensitivity increased with increasing LAA -950 in both tomosynthesis and radiography. • Tomosynthesis imparts a similar radiation dose to two projection chest radiography. • Radiation dose and cost of tomosynthesis are lower than those of MDCT.
Chow, Benjamin J W; Freeman, Michael R; Bowen, James M; Levin, Leslie; Hopkins, Robert B; Provost, Yves; Tarride, Jean-Eric; Dennie, Carole; Cohen, Eric A; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan R; Paul, Narinder; Parker, John D; O'Reilly, Daria J; Xie, Feng; Goeree, Ron
2011-06-13
Computed tomographic coronary angiography (CTCA) has gained clinical acceptance for the detection of obstructive coronary artery disease. Although single-center studies have demonstrated excellent accuracy, multicenter studies have yielded variable results. The true diagnostic accuracy of CTCA in the "real world" remains uncertain. We conducted a field evaluation comparing multidetector CTCA with invasive CA (ICA) to understand CTCA's diagnostic accuracy in a real-world setting. A multicenter cohort study of patients awaiting ICA was conducted between September 2006 and June 2009. All patients had either a low or an intermediate pretest probability for coronary artery disease and underwent CTCA and ICA within 10 days. The results of CTCA and ICA were interpreted visually by local expert observers who were blinded to all clinical data and imaging results. Using a patient-based analysis (diameter stenosis ≥50%) of 169 patients, the sensitivity, specificity, positive predictive value, and negative predictive value were 81.3% (95% confidence interval [CI], 71.0%-89.1%), 93.3% (95% CI, 85.9%-97.5%), 91.6% (95% CI, 82.5%-96.8%), and 84.7% (95% CI, 76.0%-91.2%), respectively; the area under receiver operating characteristic curve was 0.873. The diagnostic accuracy varied across centers (P < .001), with a sensitivity, specificity, positive predictive value, and negative predictive value ranging from 50.0% to 93.2%, 92.0% to 100%, 84.6% to 100%, and 42.9% to 94.7%, respectively. Compared with ICA, CTCA appears to have good accuracy; however, there was variability in diagnostic accuracy across centers. Factors affecting institutional variability need to be better understood before CTCA is universally adopted. Additional real-world evaluations are needed to fully understand the impact of CTCA on clinical care. clinicaltrials.gov Identifier: NCT00371891.
Minamiguchi, Hiroki; Kawai, Nobuyuki; Sato, Morio; Ikoma, Akira; Sanda, Hiroki; Nakata, Kouhei; Tanaka, Fumihiro; Nakai, Motoki; Sonomura, Tetsuo; Murotani, Kazuhiro; Hosokawa, Seiki; Nishioku, Tadayoshi
2014-01-01
Aortography for detecting hemorrhage is limited when determining the catheter treatment strategy because the artery responsible for hemorrhage commonly overlaps organs and non-responsible arteries. Selective catheterization of untargeted arteries would result in repeated arteriography, large volumes of contrast medium, and extended time. A volume-rendered hemorrhage-responsible arteriogram created with 64 multidetector-row CT (64MDCT) during aortography (MDCTAo) can be used both for hemorrhage mapping and catheter navigation. The MDCTAo depicted hemorrhage in 61 of 71 cases of suspected acute arterial bleeding treated at our institute in the last 3 years. Complete hemostasis by embolization was achieved in all cases. The hemorrhage-responsible arteriogram was used for navigation during catheterization, thus assisting successful embolization. Hemorrhage was not visualized in the remaining 10 patients, of whom 6 had a pseudoaneurysm in a visceral artery; 1 with urinary bladder bleeding and 1 with chest wall hemorrhage had gaze tamponade; and 1 with urinary bladder hemorrhage and 1 with uterine hemorrhage had spastic arteries. Six patients with pseudoaneurysm underwent preventive embolization and the other 4 patients were managed by watchful observation. MDCTAo has the advantage of depicting the arteries responsible for hemoptysis, whether from the bronchial arteries or other systemic arteries, in a single scan. MDCTAo is particularly useful for identifying the source of acute arterial bleeding in the pancreatic arcade area, which is supplied by both the celiac and superior mesenteric arteries. In a case of pelvic hemorrhage, MDCTAo identified the responsible artery from among numerous overlapping visceral arteries that branched from the internal iliac arteries. In conclusion, a hemorrhage-responsible arteriogram created by 64MDCT immediately before catheterization is useful for deciding the catheter treatment strategy for acute arterial bleeding.
Woodhams, Reiko; Nishimaki, Hiroshi; Fujii, Kaoru; Kakita, Satoko; Hayakawa, Kazushige
2010-10-01
The purpose of this study was to assess the efficacy of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI) by analyzing morphology and diameter of superior mesenteric artery (SMA). We assessed whether MDCT was as useful as angiography for the diagnosis of NOMI. Four patients who were diagnosed with NOMI were retrospectively analyzed. All patients had 8-row MDCT followed by laparotomy. Two of them underwent angiography after MDCT. The morphology and diameter of SMA of these cases was analyzed on multi-planar reconstructed (MPR) images. The mean diameter of SMA of NOMI cases was compared to that of 13 control cases. MPR images of all NOMI cases showed irregular narrowing of the SMA, spasm of the arcades of SMA, and poor demonstration of intramural vessels. MPR images of two patients who had angiography were concordant with their angiograms. The mean diameter of SMA of NOMI patients was 3.4±1.1mm, which was statistically smaller than that of 13 control patients, 6.0±1.5mm (P<0.05, Wilcoxon rank sum tests). Angiography has been recognized essential for the diagnosis of NOMI. This study shows the possibility of MDCT to be an equivalently useful modality compared to angiography for the diagnosis of NOMI by interpreting morphologic appearance and diameter of SMA. Introduction of MDCT in the decision tree of NOMI treatment may bring the benefit of prompt diagnosis and subsequent early and efficient initiation of therapy, which may improve the mortality. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Jeon, Sun Kyung; Choi, Young Hun; Cheon, Jung-Eun; Kim, Woo Sun; Cho, Yeon Jin; Ha, Ji Young; Lee, Seung Hyun; Hyun, Hyejin; Kim, In-One
2018-04-01
The 320-row multidetector computed tomography (CT) scanner has multiple scan modes, including volumetric modes. To compare the image quality and radiation dose of 320-row CT in three acquisition modes - helical, one-shot volume, and wide-volume scan - at pediatric brain imaging. Fifty-seven children underwent unenhanced brain CT using one of three scan modes (helical scan, n=21; one-shot volume scan, n=17; wide-volume scan, n=19). For qualitative analysis, two reviewers evaluated overall image quality and image noise using a 5-point grading system. For quantitative analysis, signal-to-noise ratio, image noise and posterior fossa artifact index were calculated. To measure the radiation dose, adjusted CT dose index per unit volume (CTDI adj ) and dose length product (DLP) were compared. Qualitatively, the wide-volume scan showed significantly less image noise than the helical scan (P=0.009), and less streak artifact than the one-shot volume scan (P=0.001). The helical mode showed significantly lower signal-to-noise ratio, with a higher image noise level compared with the one-shot volume and wide-volume modes (all P<0.05). The CTDI adj and DLP were significantly lower in the one-shot volume and wide-volume modes compared with those in the helical scan mode (all P<0.05). For pediatric unenhanced brain CT, both the wide-volume and one-shot volume scans reduced radiation dose compared to the helical scan mode, while the wide-volume scan mode showed fewer streak artifacts in the skull vertex and posterior fossa than the one-shot volume scan.
Mei, Kai; Kopp, Felix K; Bippus, Rolf; Köhler, Thomas; Schwaiger, Benedikt J; Gersing, Alexandra S; Fehringer, Andreas; Sauter, Andreas; Münzel, Daniela; Pfeiffer, Franz; Rummeny, Ernst J; Kirschke, Jan S; Noël, Peter B; Baum, Thomas
2017-12-01
Osteoporosis diagnosis using multidetector CT (MDCT) is limited to relatively high radiation exposure. We investigated the effect of simulated ultra-low-dose protocols on in-vivo bone mineral density (BMD) and quantitative trabecular bone assessment. Institutional review board approval was obtained. Twelve subjects with osteoporotic vertebral fractures and 12 age- and gender-matched controls undergoing routine thoracic and abdominal MDCT were included (average effective dose: 10 mSv). Ultra-low radiation examinations were achieved by simulating lower tube currents and sparse samplings at 50%, 25% and 10% of the original dose. BMD and trabecular bone parameters were extracted in T10-L5. Except for BMD measurements in sparse sampling data, absolute values of all parameters derived from ultra-low-dose data were significantly different from those derived from original dose images (p<0.05). BMD, apparent bone fraction and trabecular thickness were still consistently lower in subjects with than in those without fractures (p<0.05). In ultra-low-dose scans, BMD and microstructure parameters were able to differentiate subjects with and without vertebral fractures, suggesting osteoporosis diagnosis is feasible. However, absolute values differed from original values. BMD from sparse sampling appeared to be more robust. This dose-dependency of parameters should be considered for future clinical use. • BMD and quantitative bone parameters are assessable in ultra-low-dose in vivo MDCT scans. • Bone mineral density does not change significantly when sparse sampling is applied. • Quantitative trabecular bone microstructure measurements are sensitive to dose reduction. • Osteoporosis subjects could be differentiated even at 10% of original dose. • Radiation exposure should be considered when comparing quantitative bone parameters.
Jung, Seung Chai; Cho, Jeong Yeon
2011-01-01
Objective To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal streak artifact with contrast media of different iodine concentrations. Materials and Methods A 16-row MDCT was performed in 15 sedated rabbits by injection of 2 mL contrast media/kg body weight at a rate of 0.3 mL/sec. Monomeric nonionic contrast media of 250, 300, and 370 mg iodine/mL were injected at 1-week intervals. Mean attenuation values were measured in each renal structure with attenuation differences among the structures. The artifact was evaluated by CT window width/level and three grading methods. The values were compared with iodine concentrations. Results The 370 mg iodine/mL concentration showed significantly higher cortical enhancement than 250 mg iodine/mL in all phases (p < 0.05). There was however no significant difference in the degree of enhancement between the 300 mg iodine/mL and 370 mg iodine/mL concentrations in all phases. There is a significant difference in attenuation for the cortex-outer medulla between 250 mg iodine/mL and 300 mg iodine/mL (p < 0.05). The artifact was more severe with a medium of 370 mg iodine/mL than with 250 mg iodine/mL by all grading methods (p < 0.05). Conclusion The 300 mg iodine/mL is considered to be the most appropriate iodine concentration in an aspect of the enhancement and artifact on a kidney MDCT scan. PMID:22043154
Shokri, Abbas; Bidgoli, Mohsen; Akbarzadeh, Mahdi; Ghazikhanlu-Sani, Karim; Fallahi-Sichani, Hamed
2018-01-01
Purpose This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. Materials and Methods A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values (MGVs) of each cylinder were calculated in each imaging protocol. Results In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes (P<.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. Conclusion The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results. PMID:29581947
Isotani, Shuji; Shimoyama, Hirofumi; Yokota, Isao; Noma, Yasuhiro; Kitamura, Kousuke; China, Toshiyuki; Saito, Keisuke; Hisasue, Shin-ichi; Ide, Hisamitsu; Muto, Satoru; Yamaguchi, Raizo; Ukimura, Osamu; Gill, Inderbir S; Horie, Shigeo
2015-10-01
The predictive model of postoperative renal function may impact on planning nephrectomy. To develop the novel predictive model using combination of clinical indices with computer volumetry to measure the preserved renal cortex volume (RCV) using multidetector computed tomography (MDCT), and to prospectively validate performance of the model. Total 60 patients undergoing radical nephrectomy from 2011 to 2013 participated, including a development cohort of 39 patients and an external validation cohort of 21 patients. RCV was calculated by voxel count using software (Vincent, FUJIFILM). Renal function before and after radical nephrectomy was assessed via the estimated glomerular filtration rate (eGFR). Factors affecting postoperative eGFR were examined by regression analysis to develop the novel model for predicting postoperative eGFR with a backward elimination method. The predictive model was externally validated and the performance of the model was compared with that of the previously reported models. The postoperative eGFR value was associated with age, preoperative eGFR, preserved renal parenchymal volume (RPV), preserved RCV, % of RPV alteration, and % of RCV alteration (p < 0.01). The significant correlated variables for %eGFR alteration were %RCV preservation (r = 0.58, p < 0.01) and %RPV preservation (r = 0.54, p < 0.01). We developed our regression model as follows: postoperative eGFR = 57.87 - 0.55(age) - 15.01(body surface area) + 0.30(preoperative eGFR) + 52.92(%RCV preservation). Strong correlation was seen between postoperative eGFR and the calculated estimation model (r = 0.83; p < 0.001). The external validation cohort (n = 21) showed our model outperformed previously reported models. Combining MDCT renal volumetry and clinical indices might yield an important tool for predicting postoperative renal function.
Kim, Inwha; Kim, Dae Jung; Kim, Kyoung Ah; Yoon, Sang Wook; Lee, Jong Tae
2014-01-01
To investigate the feasibility and accuracy of multidetector computed tomography (MDCT) angiography for assessment of subsegmental tumor-feeding vessels in transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC). A total of 23 patients with 36 HCCs who underwent TACE during a 14-month period were enrolled. All patients underwent 3-phase dynamic MDCT within a month before TACE. Arterial phase MDCT images were retrospectively reformatted and analyzed for determination of single subsegmental tumor-feeding vessel using maximum intensity projection (MIP) and volume-rendering technique (VRT). Two radiologists independently assessed and scored the MIP and VRT images using 4-grade visual scores (grade 1, no depiction of tumor-feeding vessel; grade 2, indeterminate tumor-feeding vessel; grade 3, probable tumor-feeding vessel; and grade 4, good depiction of tumor-feeding vessel). The weighted kappa test was used to determine interobserver variability, and Wilcoxon signed rank test was used to differentiate visual scores of each technique. Results of digital subtraction angiography were defined as the criterion standard; therefore, assessment of subsegmental tumor-feeding vessel using MIP or VRT was compared with digital subtraction angiography, and the accuracy of each technique was calculated. Interobserver agreement (weighted kappa, 0.746 on VRT and 0.806 on MIP) was substantial to almost perfect. The visual scores for MIP (mean, 3.64 for reviewer 1 and 3.5 for reviewer 2) were higher than those for VRT (mean, 2.11 for reviewer 1 and 2.22 for reviewer 2; P = 0.000). The accuracy for assessing subsegmental tumor-feeding vessel was 22.2% for VRT and 77.8% for MIP. Multidetector CT angiography using MIP showed good imaging quality and high accuracy for determination of subsegmental tumor-feeding vessels.
Lee, Jeong-Min; Kim, Myeong-Jin; Phongkitkarun, Sith; Sobhonslidsuk, Abhasnee; Holtorf, Anke-Peggy; Rinde, Harald; Bergmann, Karsten
2016-08-01
The effectiveness of treatment decisions and economic outcomes of using gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging (Gd-EOB-DTPA-MRI) were compared with extracellular contrast media-enhanced MRI (ECCM-MRI) and multi-detector computed tomography (MDCT) as initial procedures in patients with suspected hepatocellular carcinoma (HCC) in South Korea and Thailand. A decision-tree model simulated the clinical pathway for patients with suspected HCC from the first imaging procedure to a confirmed treatment decision. Input data (probabilities and resource consumptions) were estimated and validated by clinical experts. Costs for diagnostic alternatives and related treatment options were derived from published sources, taking into account both payer's and hospital's perspectives. All experts from Korea and Thailand agreed that Gd-EOB-DTPA-MRI yields the highest diagnostic certainty and minimizes the need for additional confirmatory diagnostic procedures in HCC. In Korea, from the payer's perspective, total cost was USD $3087/patient to reach a confirmed treatment decision using Gd-EOB-DTPA-MRI (vs $3205/patient for MDCT and $3403/patient for ECCM-MRI). From the hospital's perspective, Gd-EOB-DTPA-MRI incurred the lowest cost ($2289/patient vs $2320/patient and $2528/patient, respectively). In Thailand, Gd-EOB-DTPA-MRI was the least costly alternative for the payer ($702/patient vs $931/patient for MDCT and $873/patient for ECCM-MRI). From the hospital's perspective, costs were $1106/patient, $1178/patient, and $1087/patient for Gd-EOB-DTPA-MRI, MDCT, and ECCM-MRI, respectively. Gd-EOB-DTPA-MRI as an initial imaging procedure in patients with suspected HCC provides better diagnostic certainty and relevant statutory health insurance cost savings in Thailand and Korea, compared with ECCM-MRI and MDCT.
Ichikawa, Katsuhiro; Hara, Takanori; Urikura, Atsushi; Takata, Tadanori; Ohashi, Kazuya
2015-06-01
The purpose of this study was to propose a method for assessing the temporal resolution (TR) of multi-detector row computed tomography (CT) (MDCT) in the helical acquisition mode using temporal impulse signals generated by a metal ball passing through the acquisition plane. An 11-mm diameter metal ball was shot along the central axis at approximately 5 m/s during a helical acquisition, and the temporal sensitivity profile (TSP) was measured from the streak image intensities in the reconstructed helical CT images. To assess the validity, we compared the measured and theoretical TSPs for the 4-channel modes of two MDCT systems. A 64-channel MDCT system was used to compare TSPs and image quality of a motion phantom for the pitch factors P of 0.6, 0.8, 1.0 and 1.2 with a rotation time R of 0.5 s, and for two R/P combinations of 0.5/1.2 and 0.33/0.8. Moreover, the temporal transfer functions (TFs) were calculated from the obtained TSPs. The measured and theoretical TSPs showed perfect agreement. The TSP narrowed with an increase in the pitch factor. The image sharpness of the 0.33/0.8 combination was inferior to that of the 0.5/1.2 combination, despite their almost identical full width at tenth maximum values. The temporal TFs quantitatively confirmed these differences. The TSP results demonstrated that the TR in the helical acquisition mode significantly depended on the pitch factor as well as the rotation time, and the pitch factor and reconstruction algorithm affected the TSP shape. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Matsutani, Hideyuki; Sano, Tomonari; Kondo, Takeshi; Fujimoto, Shinichiro; Sekine, Takako; Arai, Takehiro; Morita, Hitomi; Takase, Shinichi
2010-12-20
A high radiation dose associated with 64 multidetector-row computed tomography (64-MDCT) is a major concern for physicians and patients alike. A new 320 row area detector computed tomography (ADCT) can obtain a view of the entire heart with one rotation (0.35 s) without requiring the helical method. As such, ADCT is expected to reduce the radiation dose. We studied image quality and radiation dose of ADCT compared to that of 64-MDCT in patients with a low heart rate (HR≤60). Three hundred eighty-five consecutive patients underwent 64-MDCT and 379 patients, ADCT. Patients with an arrhythmia were excluded. Prospective ECG-gated helical scan with high HP (FlashScan) in 64 was used for MDCT and prospective ECG-gated conventional one beat scan, for 320-ADCT. Image quality was visually evaluated by an image quality score. Radiation dose was estimated by DLP (mGy・cm) for 64-MDCT and DLP.e (mGy・cm) for 320-ADCT. Radiation dose of 320-ADCT (208±48 mGy・cm) was significantly (P<0.0001) lower than that of 64-MDCT (484±112 mGy・cm), and image quality score of 320-ADCT (3.0±0.2) was significantly (P=0.0011) higher than that of 64-MDCT (2.9±0.4). Scan time of 320-ADCT (1.4±0.1 s) was also significantly (P<0.0001) shorter than that of 64-MDCT (6.8±0.6 s). 320-ADCT can achieve not only a reduction in radiation dose but also a superior image quality and shortening of scan time compared to 64-MDCT.
Park, Jung Mi; Kim, Il Young; Kim, Sang Won; Lee, Sang Mi; Kim, Hyun Gi; Kim, Shin Young; Shin, Hyung Chul
2013-04-01
The aim of this study was to compare the diagnosability between (18)F-fluorodeoxyglucose (FDG) PET/CT and enhanced multi-detector CT (MDCT) for the detection of liver metastasis (LM) according to the size and location in liver and to evaluate standard maximum standardized uptake values (SUVmax) of all liver metastatic lesions. One hundred two consecutive patients with malignancy who underwent both FDG PET/CT and MDCT for LM evaluation were retrospectively reviewed. Among them, 56 patients with LM were enrolled in this study. LM was confirmed by follow-up imaging studies after at least 6 months or by histopathology. FDG PET/CT and MDCT images were visually analyzed using three-point scale by the consensus of two radiologists and two nuclear medicine physicians. The size and location (central vs. sub-capsular) of the all liver lesions were evaluated using MDCT images. Furthermore, SUVmax of all liver lesions on FDG PET/CT images were calculated. A total of 146 liver lesions were detected by FDG PET/CT and MDCT and 142 of the lesions were diagnosed as LM. The detection rates of MDCT and FDG PET/CT for LM by visual analysis were 77 and 78%, respectively. There was no significant difference of detection rate according to the overall location and size of the lesions. However, FDG PET/CT was more sensitive than MDCT for detecting small and sub-capsular LM. The detection rate of FDG PET/CT for LM was 68% by the cutoff SUVmax of 2.7. Although the diagnosabilities of MDCT and FDG PET/CT for detecting LM were comparable, FDG PET/CT is superior to MDCT for detecting small LM located in the sub-capsular portion of liver.
Combined pulse-oximeter-NIRS system for biotissue diagnostics
NASA Astrophysics Data System (ADS)
Hovhannisyan, Vladimir A.
2005-08-01
Multi-wavelength (670, 805, 848 and 905 nm), multi-detector device for non-invasive measurement of biochemical components concentration in human or animal tissues, combining the methods of conventional pulse-oximetry and near infrared spectroscopy, is developed. The portable and clinically applicable system allows to measure heart pulse rate, oxygen saturation of arterial hemoglobin (pulse-oximetry method) and local absolute concentration of oxyhemoglobin, deoxyhemoglobin and oxidized cytochrome aa3 or other IR absorbed compounds (NIRS method). The system can be applied in monitoring of oxygen availability and utilization by the brain in neonatal and adults, neuro- traumatology, intensive care medicine, transplantation and plastic surgery, in sport, high-altitude and aviation medicine.
Watson, Tom Anthony; Arthurs, Owen John; Muthialu, Nagarajan; Calder, Alistair Duncan
2014-02-01
Cerebro-costo-mandibular syndrome (CCMS) describes a triad of mandibular hypoplasia, brain dysfunction and posterior rib defects ("rib gaps"). We present the CT imaging for a 2-year-old girl with CCMS that highlights the rib gap defects and shows absent transverse processes with abnormal fusion of the ribs directly to the vertebral bodies. We argue that this is likely to relate to abnormal lateral sclerotome development in embryology, with the failure of normal costo-vertebral junctions compounding impaired thoracic function. The case also highlights the use of CT for specific indications in skeletal dysplasia.
Study of resonances produced in light nuclei through two and multi particle correlations
NASA Astrophysics Data System (ADS)
Quattrocchi, L.; Acosta, L.; Amorini, F.; Anzalone, A.; Auditore, L.; Berceanu, I.; Cardella, G.; Chbihi, A.; De Filippo, E.; De Luca, S.; Dell' Aquila, D.; Francalanza, L.; Gnoffo, B.; Grzeszczuk, A.; Lanzalone, G.; Lombardo, I.; Martel, I.; Martorana, N. S.; Minniti, T.; Norella, S.; Pagano, A.; Pagano, E. V.; Papa, M.; Pirrone, S.; Politi, G.; Porto, F.; Rizzo, F.; Rosato, E.; Russotto, P.; Trifirò, A.; Trimarchi, M.; Verde, G.; Veselsky, M.; Vigilante, M.
2017-06-01
CORRELATION experiment has been performed at INFN-LNS of Catania, using the 4π multi-detector CHIMERA, with the aim of exploring correlations between two and multi light particle produced in 12C+24Mg collisions at 35 AMeV. Particular attention has been paid to the decay mechanisms of Hoyle state, an excited resonant state of 12C produced via the triple-α process and characterized by a pronounced molecular like structure with three α particles. The study of the Hoyle state is essential for nucleosynthesis, but it also represents a clearly isolated state that can be studied as a three-α cluster system.
Radiologic evaluation of acute chest pain--suspected myocardial ischemia.
Stanford, William
2007-08-15
The American College of Radiology has developed appropriateness criteria for a number of clinical conditions and procedures. Criteria are available on imaging tests used in the evaluation of acute chest pain--suspected myocardial ischemia. Imaging tests for a suspected cardiac etiology include transthoracic echocardiography, transesophageal echocardiography, radionuclide perfusion imaging, radionuclide ventriculography, radionuclide infarct avid imaging, and positron emission tomography. If the cardiac ischemic work-up is negative or indeterminate, applicable tests include chest radiography; conventional, multidetector, and electron beam computed tomography; and magnetic resonance imaging. A summary of the criteria, with the advantages and limitations of each test, is presented in this article.
Aladmawi, Mohamed A.; Vriz, Olga; Galzerano, Domenico
2017-01-01
Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus. PMID:28540078
Mladenovic, Zorica; Vranes, Danijela; Obradovic, Slobodan; Dzudovic, Boris; Angelkov Ristic, Andjelka; Ratkovic, Nenad; Jovic, Zoran; Spasic, Marijan; Maric Kocijancic, Jelena; Djruic, Predrag
2018-06-04
Unicuspid aortic valve (UAV) is a rare congenital anomaly of aorta associated with a faster progress of valvular dysfunction, aortic dilatation and with necessity for more frequent controls and precise evaluation Asymptomatic 35 year old man had abnormal systolic diastolic murmur on aortic valve during routine examination. Initial diagnostic with transthoracic echocardiography (TTE) supposed bicuspid aortic valve, while three-dimensional transesophageal echocardiography (3D TEE) and multidetector computed tomography defined unicuspid, unicomissural aortic valve with moderate aortic stenosis and regurgitation. This case report confirmed that 3D TEE gives us opportunity for early, improved and precise diagnosis of UAV. © 2018 Wiley Periodicals, Inc.
Gunn, P J; Weaver, A D; Lemenager, R P; Gerrard, D E; Claeys, M C; Lake, S L
2009-09-01
The objective of this study was to evaluate the influence of dietary protein and fat from distillers dried grains with solubles (DDGS) on feedlot performance, carcass characteristics, and meat quality in finishing steers. Angus-cross steers (n = 105; 443 +/- 20 kg of BW) were blocked by BW and randomly assigned to 1 of 5 dietary treatments: 1) corn-based diet with DDGS included at 25% of DM (CON), 2) CON with DDGS included at twice the amount of CON (50% of DM; 50DDGS), 3) CON with added corn protein to equal the CP in the 50DDGS diet (CON+CP), 4) CON with added vegetable oil to equal the fat in the 50DDGS diet (CON+VO), and 5) CON with protein and fat added to equal the CP and fat in the 50DDGS diet (CON+CPVO). Steers were fed to a common 12th-rib fat depth endpoint (1.3 +/- 0.2 cm; 68 to 125 d on trial). Loins and rounds were collected from 44 carcasses for Warner-Bratzler shear force (WBSF), ether extract, and case-life analyses. Data were analyzed using the MIXED procedure of SAS. Contrasts between 1) CON vs. elevated CP diets (50DDGS, CON+CP, and CON+CPVO; EP), 2) CON vs. elevated fat diets (50DDGS, CON+VO, and CON+CPVO; EF) and 3) CON vs. diets with elevated CP and fat (50DDGS and CON+CPVO; EPF) were analyzed. There were no differences in days on feed or DMI among treatments. Steers fed CON had greater ADG (P
Park, Soyun; Kim, Min-Sung; Jang, Woongsik; Park, Jin Kuen; Wang, Dong Hwan
2018-03-08
Herein, solvent-treated bandgap-tunable covalent organic nanosheets (CONs) were prepared via the Stille cross-coupling reaction. These materials are considered useful as interlayers in photovoltaic devices upon the alignment of energy levels between other components. Among various types of solar cells, according to the organic-interlayer study, inverted planar perovskite solar cells (PSCs) are mostly demanded to effectively transport and collect charge carriers due to their high performance. At first, the C-V analysis proved the energy levels of the frontier orbitals for CON-10 and CON-16 nanosheets; this verified the suitability of these nanosheets as hole transport layers (HTLs) with the PEDOT:PSS upon casting both films from DMSO. It became evident, however, that the hole transport property of the PEDOT:PSS on the CON-16 layer was unfavorable with the increasing UPS-proven hole injection barrier. In addition, both CONs induced a rough surface morphology; however, CON-10 showed a relatively smooth surface as compared to CON-16 based on the Scanning electron microscopy (SEM) and Atomic force microscopy (AFM) profiles; furthermore, their surface properties influenced both the PEDOT:PSS layers and the perovskite layers. Especially, the XRD profiles presented an enhanced crystallinity of the perovskite layers with CON-10. All these aspects indicate that CON-10 is a more effective HTL material, and several versions of perovskite solar cells (PSCs) have been fabricated with/without CON-10 and CON-16 together with the PEDOT:PSS to determine the more-HTL-suitable CON. As a result, the power conversion efficiencies (PCEs) of the optimized devices with CON-10 exhibited a value of 10.2%, which represented a 1% increase over those of the reference devices without the CONs and was 4% higher than that of the CON-16 devices. Moreover, the devices with CON-10 were further optimized with TiO x using Al electrodes, leading to a PCE increase of these devices that became slightly higher than the PCEs of the device with CON-10 and without TiO x . This tendency was supported by photoluminescence (PL) spectroscopy, photocurrent density (J ph ), and space-charge-limited current (SCLC) mobility results.
Nanda, Tavish; Dunbar, Kristen E; Campbell, Ashley A; Bathras, Ryan M; Kazim, Michael
2018-05-18
Despite the paucity of supporting data, it has generally been held that proptosis in thyroid eye disease (TED) may provide relative protection from compressive optic neuropathy (CON) by producing spontaneous decompression. The objective of this study was to investigate this phenomenon in patients with bilateral TED-CON. We retrospectively reviewed the charts of 67 patients (134 orbits) with bilateral TED-CON at Columbia-Presbyterian Medical Center. Significant asymmetric proptosis (Hertel) was defined as ≥ 2 mm. Significant asymmetric CON was defined first, as the presence of an relative afferent pupillary defect. Those without an relative afferent pupillary defect were evaluated according to the TED-CON formula y = -0.69 - 0.31 × (motility) - 0.2 × (mean deviation) - 0.02 × (color vision) as previously established for the diagnosis of TED-CON. A difference in the formula result ≥ 1.0 between eyes was considered significant. Patients were then divided into 4 groups. Forty-one of 67 patients demonstrated asymmetric CON (29 by relative afferent pupillary defect, 12 by formula). Twenty-one of 67 patients demonstrated asymmetric proptosis. Only 5 of 12 (41.6%) of the patients who had both asymmetric proptosis and asymmetric CON (group 1) showed greater proptosis in the eye with less CON. Twenty-nine patients (group 2) showed that asymmetric CON occurred despite symmetrical proptosis. Seventeen patients (group 3), showed the inverse, that asymmetric differences in proptosis occurred with symmetrical CON. Despite commonly held assumptions, our results suggest that greater proptosis is not associated with improved TED-CON. Combining groups 1 to 3-all of which demonstrated asymmetry of either proptosis, CON, or both-91.4% of patients did not show a relationship between greater proptosis and improved CON.
The Pros and Cons of Army Automation
2007-11-13
The Pros and Cons of Army Automation 1 Running Head: THE PROS AND CONS OF ARMY AUTOMATION The Pros and Cons of Army Automation SGM...TITLE AND SUBTITLE The Pros and Cons of Army Automation 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...Prescribed by ANSI Std Z39-18 The Pros and Cons of Army Automation 2 Outline I. Introduction (MSG (P) Dostie) II. Manual skills (MSG (P
Iacobellis, Francesca; Ierardi, Anna M; Mazzei, Maria A; Magenta Biasina, Alberto; Carrafiello, Gianpaolo; Nicola, Refky; Scaglione, Mariano
2016-01-01
Acute vascular injuries are the second most common cause of fatalities in patients with multiple traumatic injuries; thus, prompt identification and management is essential for patient survival. Over the past few years, multidetector CT (MDCT) using dual-phase scanning protocol has become the imaging modality of choice in high-energy deceleration traumas. The objective of this article was to review the role of dual-phase MDCT in the identification and management of acute vascular injuries, particularly in the chest and abdomen following multiple traumatic injuries. In addition, this article will provide examples of MDCT features of acute vascular injuries with correlative surgical and interventional findings.
Advantage of vein grafts for anomalous origin of a right coronary artery.
Kansaku, Rei; Saitoh, Hirofumi; Eguchi, Shoji; Maruyama, Yukio; Ohtsuka, Hideaki; Higuchi, Kotaro
2009-03-01
A 66-year-old man with anomalous origin of the right coronary artery suffered from chest pain. The results of coronary angiography and multidetector computer tomography indicated that the proximal right coronary artery was intermittently compressed, causing the ischemia. Coronary artery bypass grafting was regarded as a reliable treatment compared with percutaneous coronary intervention or other surgeries. Because of plentiful flow of the right coronary artery, we decided to use a vein graft to avoid competitive flow. Postoperative coronary angiography revealed intact flow in both the native coronary artery and the vein graft 1 year after the surgery. The myocardial ischemia seen on scintigraphy and the chest pain had disappeared.
Congenital Anomaly of Single Dominant Right Coronary Artery with Hypoplastic Left Coronary Artery.
Chuang, Cheng-Yen; Chen, Yen-Chou; Cheng, Ho-Shun; Hsieh, Ming-Hsiung
2015-11-01
With the popularization of new imaging technology, more people are deciding to undergo non-invasive studies such as multidetector computerized tomography (MDCT) before receiving coronary angiography. For this reason, coronary anomalies of coronary artery are being encountered more frequently. We here report a 68-year-old male presenting with typical angina. The MDCT images suggested chronic total occlusion of the left anterior descending (LAD) artery with collateral circulation from the right coronary artery (RCA). The patient's coronary angiography showed a congenital coronary anomaly with a single dominant RCA supplying the entire coronary circulation of the heart with both LAD and left circumflex artery hypoplasia. Angiography; Anomaly; Computerized tomography; Coronary artery.
Recent advances in imaging cancer of the kidney and urinary tract.
Hilton, Susan; Jones, Lisa P
2014-10-01
Modern radiologic imaging is an aid to treatment planning for localized renal cancer, enabling characterization of mass lesions. For patients who present with advanced renal cancer, new imaging techniques enable a functional assessment of treatment response not possible using anatomic measurements alone. Multidetector CT urography permits simultaneous assessment of the kidneys and urinary tract for patients with unexplained hematuria. Both CT and MRI play a significant role in staging and follow up of patients treated for urothelial cancer. Newer imaging methods such as diffusion-weighted MRI have shown promising results for improving accuracy of staging and follow up of urothelial cancer. Copyright © 2014 Elsevier Inc. All rights reserved.
Errors in imaging of traumatic injuries.
Scaglione, Mariano; Iaselli, Francesco; Sica, Giacomo; Feragalli, Beatrice; Nicola, Refky
2015-10-01
The advent of multi-detector computed tomography (MDCT) has drastically improved the outcomes of patients with multiple traumatic injuries. However, there are still diagnostic challenges to be considered. A missed or the delay of a diagnosis in trauma patients can sometimes be related to perception or other non-visual cues, while other errors are due to poor technique or poor image quality. In order to avoid any serious complications, it is important for the practicing radiologist to be cognizant of some of the most common types of errors. The objective of this article is to review the various types of errors in the evaluation of patients with multiple trauma injuries or polytrauma with MDCT.
Importance of eccentric actions in performance adaptations to resistance training
NASA Technical Reports Server (NTRS)
Dudley, Gary A.; Miller, Bruce J.; Buchanan, Paul; Tesch, Per A.
1991-01-01
The importance of eccentric (ecc) muscle actions in resistance training for the maintenance of muscle strength and mass in hypogravity was investigated in experiments in which human subjects, divided into three groups, were asked to perform four-five sets of 6 to 12 repetitions (rep) per set of three leg press and leg extension exercises, 2 days each weeks for 19 weeks. One group, labeled 'con', performed each rep with only concentric (con) actions, while group con/ecc with performed each rep with only ecc actions; the third group, con/con, performed twice as many sets with only con actions. Control subjects did not train. It was found that resistance training wih both con and ecc actions induced greater increases in muscle strength than did training with only con actions.
2010-08-02
Cost and Price Analysis & Negotiations (5-2)—DAU CON 217 & CON 218 Certified; MN3318 Contingency Contracting (3-0)—DAU CON 234 Certified; and...MN3315 Advanced Contract Management (4-0)—DAU CON 214 & CON 215 Certified. CDR (Ret) Yoder has recently been published or cited in the following works...certified as the primary guide for all DAU CON 234 course deliveries. Contracting Out Government Procurement Functions: An Analysis (NPS-CM-07-105), E
2016-01-01
A study was undertaken with an objective of evaluating the long-term impacts of organic (ORG) and conventional (CON) methods of coffee farming on soil physical, chemical, biological, and microbial diversity. Electrical conductivity and bulk density were found to increase by 34% and 21%, respectively, in CON compared to ORG system, while water holding capacity was found decreased in both the systems. Significant increase in organic carbon was observed in ORG system. Major nutrients, nitrogen and potassium, levels showed inclination in both ORG and CON system, but the trend was much more pronounced in CON system. Phosphorus was found to increase in both ORG and CON system, but its availability was found to be more with CON system. In biological attributes, higher soil respiration and fluorescein diacetate activity were recorded in ORG system compared to CON system. Higher soil urease activity was observed in CON system, while dehydrogenase activity does not show significant differences between ORG and CON systems. ORG system was found to have higher macrofauna (31.4%), microbial population (34%), and microbial diversity indices compared to CON system. From the present study, it is accomplished that coffee soil under long-term ORG system has better soil properties compared to CON system. PMID:27042378
Velmourougane, Kulandaivelu
2016-01-01
A study was undertaken with an objective of evaluating the long-term impacts of organic (ORG) and conventional (CON) methods of coffee farming on soil physical, chemical, biological, and microbial diversity. Electrical conductivity and bulk density were found to increase by 34% and 21%, respectively, in CON compared to ORG system, while water holding capacity was found decreased in both the systems. Significant increase in organic carbon was observed in ORG system. Major nutrients, nitrogen and potassium, levels showed inclination in both ORG and CON system, but the trend was much more pronounced in CON system. Phosphorus was found to increase in both ORG and CON system, but its availability was found to be more with CON system. In biological attributes, higher soil respiration and fluorescein diacetate activity were recorded in ORG system compared to CON system. Higher soil urease activity was observed in CON system, while dehydrogenase activity does not show significant differences between ORG and CON systems. ORG system was found to have higher macrofauna (31.4%), microbial population (34%), and microbial diversity indices compared to CON system. From the present study, it is accomplished that coffee soil under long-term ORG system has better soil properties compared to CON system.
Schieck, S J; Shurson, G C; Kerr, B J; Johnston, L J
2010-12-01
Crossbred pigs (n = 216; BW = 31.3 ± 1.8 kg) were used to determine the effects of long- and short-term feeding of crude glycerol on growth performance, carcass traits, and pork quality of grow-finish pigs. Pigs were blocked by initial BW, and pens within blocks were assigned randomly to 1 of 3 dietary treatments (24 pens; 9 pigs/pen). Dietary treatments were control, a corn-soybean meal-based diet (CON); long-term, CON + 8% glycerol fed throughout the experiment (LT); and short-term, pigs fed CON for the first 6 wk followed by CON + 8% glycerol fed during the last 8 wk of the experiment (ShT). Pigs fed LT had greater (P < 0.05) ADG, whereas pigs fed ShT tended (P < 0.10) to grow faster than CON (CON = 0.962 kg/d, LT = 0.996 kg/d, and ShT = 0.992 kg/d; SE = 0.01). Pigs assigned to LT had greater (P < 0.05) ADFI compared with CON, whereas ShT-fed pigs had similar ADFI to CON (CON = 2.78 kg/d, LT = 2.93 kg/d, and ShT = 2.86 kg/d; SE = 0.03). Gain:feed tended (P < 0.10) to be greater for CON- and ShT-fed pigs compared with LT-fed pigs (CON = 0.346, LT = 0.339, and ShT = 0.346; SE = 0.002). Hot carcass weight was greater (P < 0.05) for LT-fed pigs compared with CON, whereas ShT-fed pigs had HCW similar to both LT- and CON-fed pigs (CON = 94.8 kg, LT = 97.5 kg, and ShT = 96.3 kg; SE = 0.90). Dressing percentage of CON-fed pigs was similar to both LT- and ShT-fed pigs, but LT-fed pigs tended to have greater (P = 0.06) dressing percentage than ShT-fed pigs (CON = 74.5%, LT = 74.9%, and ShT = 74.3%; SE = 0.16). Tenth-rib backfat (P = 0.26) and LM area (P = 0.17) were not affected by dietary treatment. There was a trend (P < 0.10) for LT-fed pigs to have a smaller fat-free lean percentage than CON-fed pigs (CON = 53.1%, LT = 52.26%, and ShT = 52.67%; SE = 0.25). Short-term glycerol feeding increased (P < 0.05) belly firmness compared with CON and had similar belly firmness compared with LT-fed pigs (CON = 29.46°, LT = 35.16°, and ST = 42.08°; SE = 3.07). Dietary treatment had no effect (P > 0.60) on pork quality of loins based on taste panel assessments. Feeding pigs 8% crude glycerol throughout the grow-finish period resulted in a 3% improvement in growth rate and a 2% depression in BW gain efficiency compared with CON diets. Grow-finish pigs fed diets containing 8% crude glycerol during the last 8 wk before slaughter achieved growth performance similar to pigs fed CON diets. Effects of crude glycerol on carcass traits seem to be limited to improvements in belly firmness with short-term feeding of glycerol.
78 FR 62661 - Notice of Lodging of Consent Decree Pursuant to the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-22
... and Natural Resources Division, and should refer to United States v. ConAgra Foods, Inc., and ConAgra... United States of America v. ConAgra Foods, Inc., and ConAgra Grocery Products, LLC, Civil Action No. 2:13-cv-02756. This Decree represents a settlement of claims against the Defendants ConAgra Foods, Inc...
Morioka, Shinichiro; Ichikawa, Mika; Mori, Keita; Kurai, Hanako
2018-03-16
Coagulase-negative staphylococci (CoNS) are the most common contaminants of blood cultures, however, we sometimes have difficulties in determining their clinical significance. It is still controversial that there is a significant difference between the contamination group and the true bacteraemia group in the time to positivity (TTP) of blood cultures. We validated the relationship between a TTP and the presence of CoNS bacteraemia in cancer patients by using an objective, non-judgmental definition for CoNS contamination. We retrospectively reviewed 175 sets of blood cultures drawn from 95 patients that yielded CoNS from October 2011 to March 2013. We considered as contamination if an isolate of CoNS was identified in one out of multiple sets of blood cultures. We investigated the TTP, the threshold values and corresponding likelihood ratios to distinguish CoNS bacteraemia from contamination. The median TTP in CoNS bacteraemia group was significantly shorter than that in contamination group (14 h 45 min and 20 h 31 min, respectively, p = .0157). A TTP of ≤16 h had a specificity of 83% for predicting CoNS bacteraemia, and that of >20 h had a sensitivity of 86% for predicting CoNS contamination. We validated that the median TTP in CoNS bacteraemia group was significantly shorter than that in their contamination group, and that a TTP of ≤16 h was associated with CoNS bacteraemia, while that of >20 h was associated with CoNS contamination, if evaluated with an objective, non-judgmental definition for CoNS contamination.
Hullborne Hydrofoil Six-Degree of Freedom Motion Prediction Computer Program
1976-07-01
UAVEI (7.7) , WAVE2 (797) .!NUEX(1493) .DtIM3(4034) KRN 21 NOE=2 *NO%1 KRN 22 no0 12IzlNON KPZN 23 NIxN0N- I KPN 24 FR(I.1)xEM1 CK,1) KRN 25 FR(192)2-SNE...CON7(J,1)* WAVE2 (1,J)-CON2(NJ,1 )*SOUR2(1,J) KRN III PRA(1,3)=PRA(T,3)+CON1(J,2)*WAVEi CIJ)-CON1(NJ,2)*SOUR1(I.J) KRN 112 PRA(1,4)zPRA(194) .CON2(J,2...8217 WAVE2 (lj)-CON2(NJ,2)*SOUR2(IJJ KRN 113 PPV(1.2)=PRV(192) *CON2(J,1)*SOUR2(I.J) *CON2(NJt1)* WAVE2 (1.J) KRN 115 PRV(193;=PRV(193),CONI(Jt?)4SOUR1(1,J
Interagency Rebuilding Efforts in Iraq: A Case Study of the Rusafa Political District
2013-02-26
Cart Seller 18-Aug-2010 $950.00 PRIVSEC NON-CON Cart Seller 18-Aug-2010 $500.00 PRIVSEC NON-CON Embroidery 18-Aug-2010 $22,900.00 PRIVSEC NON-CON...Kindergarten 18-Aug-2010 $11,300.00 PRIVSEC 50 NON-CON Embroidery & Sewing Factory 18-Aug-2010 $21,000.00 PRIVSEC NON-CON Book Shop 18-Aug-2010 $3,204.00
An anatomical review of spinal cord blood supply.
Melissano, G; Bertoglio, L; Rinaldi, E; Leopardi, M; Chiesa, R
2015-10-01
Knowledge of the spinal cord (SC) vascular supply is important in patients undergoing procedures that involve the thoracic and thoracoabdominal aorta. However, the SC vasculature has a complex anatomy, and teaching is often based only on anatomical sketches with highly variable accuracy; historically, this has required a "leap of faith" on the part of aortic surgeons. Fortunately, this "leap of faith" is no longer necessary given recent breakthroughs in imaging technologies and postprocessing software. Imaging methods have expanded the non-invasive diagnostic ability to determine a patient's SC vascular pattern, particularly in detecting the presence and location of the artery of Adamkiewicz. CT is the imaging modality of choice for most patients with thoracic and thoracoabdominal aortic disease, proving especially useful in the determination of feasibility and planning of endovascular treatment. Thus the data set required for analysis of SC vascular anatomy is usually already available. We have concentrated our efforts on CT angiography, which offers particularly good imaging capabilities with state-of-the-art multidetector scanners. Multidetector row helical CT provides examinations of an extensive range in the craniocaudal direction with thin collimation in a short time interval, giving excellent temporal and spatial resolution. This paper provides examples of the SC vasculature imaging quality that can be obtained with 64 row scanners and appropriate postprocessing. Knowledge of the principal anatomical features of the SC blood supply of individual patients undergoing open or endovascular thoracoabdominal procedures has several potential benefits. For open surgery, analysis of the SC vasculature could tell us the aortic region that feeds the Adamkiewicz artery and thus needs to be reimplanted. For endovascular procedures, we can determine whether the stent-graft will cover the Adamkiewicz artery, thus avoiding unnecessary coverage. CT data can also be used to stratify risk of SC ischemia and guide the selective use of spinal cord injury prevention strategies.
Finkenstaedt, Tim; Morsbach, Fabian; Calcagni, Maurizio; Vich, Magdalena; Pfirrmann, Christian W A; Alkadhi, Hatem; Runge, Val M; Andreisek, Gustav; Guggenberger, Roman
2014-08-01
The aim of this study was to compare image quality and extent of artifacts from scaphoid fracture fixation screws using different computed tomography (CT) modalities and radiation dose protocols. Imaging of 6 cadaveric wrists with artificial scaphoid fractures and different fixation screws was performed in 2 screw positions (45° and 90° orientation in relation to the x/y-axis) using multidetector CT (MDCT) and 2 flat-panel CT modalities, C-arm flat-panel CT (FPCT) and cone-beam CT (CBCT), the latter 2 with low and standard radiation dose protocols. Mean cartilage attenuation and metal artifact-induced absolute Hounsfield unit changes (= artifact extent) were measured. Two independent radiologists evaluated different image quality criteria using a 5-point Likert-scale. Interreader agreements (Cohen κ) were calculated. Mean absolute Hounsfield unit changes and quality ratings were compared using Friedman and Wilcoxon signed-rank tests. Artifact extent was significantly smaller for MDCT and standard-dose FPCT compared with CBCT low- and standard-dose acquisitions (all P < 0.05). No significant differences in artifact extent among different screw types and scanning positions were noted (P > 0.05). Both MDCT and FPCT standard-dose protocols showed equal ratings for screw bone interface, fracture line, and trabecular bone evaluation (P = 0.06, 0.2, and 0.2, respectively) and performed significantly better than FPCT low- and CBCT low- and standard-dose acquisitions (all P < 0.05). Good interreader agreement was found for image quality comparisons (Cohen κ = 0.76-0.78). Both MDCT and FPCT standard-dose acquisition showed comparatively less metal-induced artifacts and better overall image quality compared with FPCT low-dose and both CBCT acquisitions. Flat-panel CT may provide sufficient image quality to serve as a versatile CT alternative for postoperative imaging of internally fixated wrist fractures.
Zeltzer, Assaf A; Anzarut, Alexander; Braeckmans, Delphine; Seidenstuecker, Katrin; Hendrickx, Benoit; Van Hedent, Eddy; Hamdi, Moustapha
2017-09-01
A growing number of surgeons perform lymph node transfers for the treatment of lymphedema. When harvesting a vascularized lymph node groin flap (VGLNF) one of the major concerns is the potential risk of iatrogenic lymphedema of the donor-site. This article helps understanding of the lymph node distribution of the groin in order to minimize this risk. Fifty consecutive patients undergoing abdominal mapping by multi-detector CT scanner were included and 100 groins analyzed. The groin was divided in three zones (of which zone II is the safe zone) and lymph nodes were counted and mapped with their distances to anatomic landmarks. Further node units were plotted and counted. The average age was 48 years. A mean number of nodes of 6.5/groin was found. In zone II, which is our zone of interest a mean of 3.1 nodes were counted with a mean size of 7.8 mm. In three patients no nodes were found in zone II. In five patients nodes were seen in zone II but were not sufficient in size or number to be considered a lymph node unit. On average the lymph node unit in zone II was found to be 48.3 mm from the pubic tubercle when projected on a line from the pubic tubercle to the anterior superior iliac spine, 16.0 mm caudal to this line, and 20.4 mm above the groin crease. On average the lymph node unit was a mean of 41.7 mm lateral to the SCIV-SIEV confluence. This study provides increased understanding of the lymphatic anatomy in zone II of the groin flap and suggests a refined technique for designing the VGLNF. As with any flap there is a degree of individual patient variability. However, having information on the most common anatomy and flap design is of great value. © 2017 Wiley Periodicals, Inc.
Ohno, Takeshi; Araki, Fujio; Onizuka, Ryota; Hatemura, Masahiro; Shimonobou, Toshiaki; Sakamoto, Takashi; Okumura, Shuichiro; Ideguchi, Daichi; Honda, Keiichi; Kawata, Kenji
2017-03-01
This study compared dosimetric properties among four commercial multi-detector CT (MDCT) scanners. The X-ray beam characteristics were obtained from photon intensity attenuation curves of aluminum and off-center ratio (OCR) profiles in air, which were measured with four commercial MDCT scanners. The absorbed dose for MDCT scanners was evaluated with Farmer ionization chamber measurements at the center and four peripheral points in the body- and head-type cylindrical water phantoms. Measured collected charge was converted to absorbed dose using a 60 Co absorbed dose-to-water calibration factor and Monte Carlo (MC)-calculated correction factors. Four MDCT scanners were modeled to correspond with measured X-ray beam characteristics using GMctdospp (IMPS, Germany) software. Al half-value layers (Al-HVLs) with a body-bowtie filter determined from measured Al-attenuation curves ranged 7.2‒9.1mm at 120kVp and 6.1‒8.0mm at 100kVp. MC-calculated Al-HVLs and OCRs in air were in acceptable agreement within 0.5mm and 5% of measured values, respectively. The percentage difference between nominal and actual beam width was greater with decreasing collimation width. The absorbed doses for MDCT scanners at 120kVp ranged 5.1‒7.1mGy and 10.8‒17.5mGy per 100mAs at the center in the body- and head-type water phantoms, respectively. Measured doses at four peripheral points were within 5% agreement of MC-calculated values. The absorbed dose at the center in both water phantoms increased with decreasing Al-HVL for the same charge on the focus. In this study the X-ray beam characteristics and the absorbed dose were measured and compared with calculated values for four MDCT scanners. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Lee, Youn Joo; Lim, Yeon Soo; Lim, Hyun Wook; Yoo, Won Jong; Choi, Byung Gil; Kim, Bum Soo
2014-10-01
There are very few reports assessing in-stent restenosis (ISR) after vertebral artery ostium (VAO) stents using multidetector computed tomography (MDCT). To compare the diagnostic accuracy of computed tomography angiography (CTA) using 64-slice MDCT with digital subtraction angiography (DSA) for detection of significant ISR after VAO stenting. The study evaluated 57 VAO stents in 57 patients (39 men, 18 women; mean age 64 years [range, 48-90 years]). All stents were scanned with a 64-slice MDCT scanner. Three sets of images were reconstructed with three different convolution kernels. Two observers who were blinded to the results of DSA assessed the diagnostic accuracy of CTA for detecting significant ISR (≥50% diameter narrowing) of VAO stents in comparison with DSA as the reference standard. The sensitivity, specificity, positive and negative predictive values, and accuracy were calculated. Of the 57 stents, 46 (81%) were assessable using CTA, while 11 (19%) were not. No stents with diameters ≤2.75 mm were assessable. DSA revealed 13 cases of significant ISR in all stents. The respective sensitivity, specificity, positive and negative predictive values, and accuracy were 92%, 82%, 60%, 97%, and 84% for all stents. On excluding the 11 non-assessable stents, the respective values were 88%, 95%, 78%, 97%, and 93%. Of the 46 CTA assessable stents, eight significant ISRs were diagnosed on DSA. Seven of eight patients with significant ISR by DSA were diagnosed correctly with CTA. The area under the receiver-operating characteristic curve (AUC) was 0.87 for all stents and 0.91 for assessable stents, indicating good to excellent agreement between CTA and DSA for detecting significant ISR after VAO stenting. Sixty-four-slice MDCT is a promising non-invasive method of assessing stent patency and can exclude significant ISR with high diagnostic values after VAO stenting. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Takakuwa, Kevin M; Halpern, Ethan J; Shofer, Frances S
2011-02-01
The study aimed to examine time and imaging costs of 2 different imaging strategies for low-risk emergency department (ED) observation patients with acute chest pain or symptoms suggestive of acute coronary syndrome. We compared a "triple rule-out" (TRO) 64-section multidetector computed tomography protocol with nuclear stress testing. This was a prospective observational cohort study of consecutive ED patients who were enrolled in our chest pain observation protocol during a 16-month period. Our standard observation protocol included a minimum of 2 sets of cardiac enzymes at least 6 hours apart followed by a nuclear stress test. Once a week, observation patients were offered a TRO (to evaluate for coronary artery disease, thoracic dissection, and pulmonary embolus) multidetector computed tomography with the option of further stress testing for those patients found to have evidence of coronary artery disease. We analyzed 832 consecutive observation patients including 214 patients who underwent the TRO protocol. Mean total length of stay was 16.1 hours for TRO patients, 16.3 hours for TRO plus other imaging test, 22.6 hours for nuclear stress testing, 23.3 hours for nuclear stress testing plus other imaging tests, and 23.7 hours for nuclear stress testing plus TRO (P < .0001 for TRO and TRO + other test compared to stress test ± other test). Mean imaging times were 3.6, 4.4, 5.9, 7.5, and 6.6 hours, respectively (P < .05 for TRO and TRO + other test compared to stress test ± other test). Mean imaging costs were $1307 for TRO patients vs $945 for nuclear stress testing. Triple rule-out reduced total length of stay and imaging time but incurred higher imaging costs. A per-hospital analysis would be needed to determine if patient time savings justify the higher imaging costs. Copyright © 2011 Elsevier Inc. All rights reserved.
Small-airway obstruction and emphysema in chronic obstructive pulmonary disease.
McDonough, John E; Yuan, Ren; Suzuki, Masaru; Seyednejad, Nazgol; Elliott, W Mark; Sanchez, Pablo G; Wright, Alexander C; Gefter, Warren B; Litzky, Leslie; Coxson, Harvey O; Paré, Peter D; Sin, Don D; Pierce, Richard A; Woods, Jason C; McWilliams, Annette M; Mayo, John R; Lam, Stephen C; Cooper, Joel D; Hogg, James C
2011-10-27
The major sites of obstruction in chronic obstructive pulmonary disease (COPD) are small airways (<2 mm in diameter). We wanted to determine whether there was a relationship between small-airway obstruction and emphysematous destruction in COPD. We used multidetector computed tomography (CT) to compare the number of airways measuring 2.0 to 2.5 mm in 78 patients who had various stages of COPD, as judged by scoring on the Global Initiative for Chronic Obstructive Lung Disease (GOLD) scale, in isolated lungs removed from patients with COPD who underwent lung transplantation, and in donor (control) lungs. MicroCT was used to measure the extent of emphysema (mean linear intercept), the number of terminal bronchioles per milliliter of lung volume, and the minimum diameters and cross-sectional areas of terminal bronchioles. On multidetector CT, in samples from patients with COPD, as compared with control samples, the number of airways measuring 2.0 to 2.5 mm in diameter was reduced in patients with GOLD stage 1 disease (P=0.001), GOLD stage 2 disease (P=0.02), and GOLD stage 3 or 4 disease (P<0.001). MicroCT of isolated samples of lungs removed from patients with GOLD stage 4 disease showed a reduction of 81 to 99.7% in the total cross-sectional area of terminal bronchioles and a reduction of 72 to 89% in the number of terminal bronchioles (P<0.001). A comparison of the number of terminal bronchioles and dimensions at different levels of emphysematous destruction (i.e., an increasing value for the mean linear intercept) showed that the narrowing and loss of terminal bronchioles preceded emphysematous destruction in COPD (P<0.001). These results show that narrowing and disappearance of small conducting airways before the onset of emphysematous destruction can explain the increased peripheral airway resistance reported in COPD. (Funded by the National Heart, Lung, and Blood Institute and others.).
Turba, Ulku Cenk; Uflacker, Renan; Bozlar, Ugur; Hagspiel, Klaus D
2009-03-01
The purpose of this study was to determine renal arterial anatomy and gender differences in adults without renovascular disease using multidetector computed tomography angiography (MDCTA). MDCTA datasets of 399 patients were retrospectively reviewed. Measurements of the aortorenal diameters, the angulation of the renal ostia and pedicles as well as the distance between the origins of the renal arteries were measured. Differences in measurements between genders were tested for statistical significance using analysis of variance (ANOVA) and Pearson's Chi-Square tests. A total of 798 renal arteries were available for analysis in 207 female (mean age = 52.91 years) and 192 male patients (mean age = 53.04 years). Female patients were found to have smaller aortae (at the level of the right renal ostium) and bilateral renal arteries than males (mean aortic diameter M/F = 18.33/15.89 mm, mean right renal artery ostial diameter M/F = 5.06/4.59 mm, mean left ostial renal diameter M/F = 5.14/4.66 mm) (p < .001). There was no statistical significance for the renal ostia level in relation to the vertebrae and the majority of renal arteries originated at the L1 and L2 levels. The longitudinal distance between right and left renal artery ostia ranged from 0 to 32 mm (mean = 4,6 mm, median = 5mm). The mean anteroposterior orientation of the right renal ostia was M/F = 29.45 degrees/28.20 degrees , and M/F = -7.96 degrees/-11.14 degrees for left renal artery ostia. The mean anteroposterior orientation of the right renal pedicle was M/F = 41.37 degrees/44.34 degrees and M/F = 42.31 degrees/43.95 degrees for the left pedicle. There are some differences in normal renal arterial anatomy between genders. Normal renal arterial information is useful not only for planning and performing of endovascular and laparoscopic urologic procedures, but also for medical device development. Copyright 2009 Wiley-Liss, Inc.
Ateşoğlu, Sibel; Deniz, Mustafa; Uslu, Ayşe İmge
2018-01-18
Sternum is one of the skeleton parts which have frequently congenital anomalies and variations are commonly used by researchers in determining sex. We evaluated the morphological characteristics and sex-related changes of the sternum in adult individuals using multidetector CT in our study. 200 adults (103 female and 97 male) aged between 18-87 years were evaluated. Utilizing the morphological characteristics of the sternum based on the multi-slice images; length, width and the thickness of Manubrium, length, width and the thickness of Corpus Sterni, total length of Sternum, Sternal angle, Sternal index, length of the xiphoid process, the thickness of xiphoid process, the number of indents of xiphoid process were measured and a total of 20 parameters were evaluated by adding age, height and weight to these variables. The mean length of the manubrium, the length of corpus sterni, the length of total sternum, sternal index, sternal angle were found in females 46.7±5.1,86.6±9.7, 133.1±1.1, 54.47±10.0 and 163.75±5.79; in males 51.2±6, 102.4±13.3, 154.1±13.1, 50.11±10.02 and 162.21±6.17, respectively. We found that Hyrtl's law and Sternal index did not provide adequate accuracy for sex determination in our patients. It has been detected that the length of the Manubrium alone is not helpful for individual samples. Total length of the sternum was found to be more reliable than the length of the Manubrium and the length of corpus Sterni. We determined Sternal cleft and Sternal foramen as 0.5% and 3.5%, respectively. We suggest that the Morphometric standards cannot be universally applied and can demonstrate individual differences. The standard rules must be implemented for every population.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohno, T; Araki, F
2015-06-15
Purpose: To compare dosimetric properties and patient organ doses from four commercial multidetector CT (MDCT) using Monte Carlo (MC) simulation based on the absorbed dose measured using a Farmer chamber and cylindrical water phantoms according to AAPM TG-111. Methods: Four commercial MDCT were modeled using the GMctdospp (IMPS, Germany) based on the EGSnrc user code. The incident photon spectrum and bowtie filter for MC simulations were determined so that calculated values of aluminum half-value layer (Al-HVL) and off-center ratio (OCR) profile in air agreed with measured values. The MC dose was calibrated from absorbed dose measurements using a Farmer chambermore » and cylindrical water phantoms. The dose distributions of head, chest, and abdominal scan were calculated using patient CT images and mean organ doses were evaluated from dose volume histograms. Results: The HVLs at 120 kVp of Brilliance, LightSpeed, Aquilion, and SOMATOM were 9.1, 7.5, 7.2, and 8.7 mm, respectively. The calculated Al-HVLs agreed with measurements within 0.3%. The calculated and measured OCR profiles agreed within 5%. For adult head scans, mean doses for eye lens from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.7, 38.5, 47.2 and 28.4 mGy, respectively. For chest scans, mean doses for lung from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.1, 26.1, 35.3 and 24.0 mGy, respectively. For adult abdominal scans, the mean doses for liver from Brilliance, LightSpeed, Aquilion, and SOMATOM were 16.5, 21.3, 22.7, and 18.0 mGy, respectively. The absorbed doses increased with decreasing Al-HVL. The organ doses from Aquilion were two greater than those from Brilliance in head scan. Conclusion: MC dose distributions based on absorbed dose measurement in cylindrical water phantom are useful to evaluate individual patient organ doses.« less
Chu, Zhi-gang; Yang, Zhi-gang; Dong, Zhi-hui; Chen, Tian-wu; Zhu, Zhi-yu; Shao, Heng
2011-01-01
OBJECTIVE: The features of earthquake-related head injuries may be different from those of injuries obtained in daily life because of differences in circumstances. We aim to compare the features of head traumas caused by the Sichuan earthquake with those of other common head traumas using multidetector computed tomography. METHODS: In total, 221 patients with earthquake-related head traumas (the earthquake group) and 221 patients with other common head traumas (the non-earthquake group) were enrolled in our study, and their computed tomographic findings were compared. We focused the differences between fractures and intracranial injuries and the relationships between extracranial and intracranial injuries. RESULTS: More earthquake-related cases had only extracranial soft tissue injuries (50.7% vs. 26.2%, RR = 1.9), and fewer cases had intracranial injuries (17.2% vs. 50.7%, RR = 0.3) compared with the non-earthquake group. For patients with fractures and intracranial injuries, there were fewer cases with craniocerebral injuries in the earthquake group (60.6% vs. 77.9%, RR = 0.8), and the earthquake-injured patients had fewer fractures and intracranial injuries overall (1.5±0.9 vs. 2.5±1.8; 1.3±0.5 vs. 2.1±1.1). Compared with the non-earthquake group, the incidences of soft tissue injuries and cranial fractures combined with intracranial injuries in the earthquake group were significantly lower (9.8% vs. 43.7%, RR = 0.2; 35.1% vs. 82.2%, RR = 0.4). CONCLUSION: As depicted with computed tomography, the severity of earthquake-related head traumas in survivors was milder, and isolated extracranial injuries were more common in earthquake-related head traumas than in non-earthquake-related injuries, which may have been the result of different injury causes, mechanisms and settings. PMID:22012045
Wielpütz, Mark O.; Weinheimer, Oliver; Eichinger, Monika; Wiebel, Matthias; Biederer, Jürgen; Kauczor, Hans-Ulrich; Heußel, Claus P.
2013-01-01
Background Histopathological studies on lung specimens from patients with cystic fibrosis (CF) and recent results from a mouse model indicate that emphysema may contribute to CF lung disease. However, little is known about the relevance of emphysema in patients with CF. In the present study, we used computationally generated density masks based on multidetector computed tomography (MDCT) of the chest for non-invasive characterization and quantification of emphysema in CF. Methods Volumetric MDCT scans were acquired in parallel to pulmonary function testing in 41 patients with CF (median age 20.1 years; range 7-66 years) and 21 non-CF controls (median age 30.4 years; range 4-68 years), and subjected to dedicated software. The lung was segmented, low attenuation volumes below a threshold of -950 Hounsfield units were assigned to emphysema volume (EV), and the emphysema index was computed (EI). Results were correlated with forced expiratory volume in 1 s percent predicted (FEV1%), residual volume (RV), and RV/total lung capacity (RV/TLC). Results We show that EV was increased in CF (457±530 ml) compared to non-CF controls (78±90 ml) (P<0.01). EI was also increased in CF (7.7±7.5%) compared to the control group (1.2±1.4%) (P<0.05). EI correlated inversely with FEV1% (rs=-0.66), and directly with RV (rs=0.69) and RV/TLC (rs=0.47) in patients with CF (P<0.007), but not in non-CF controls. Emphysema in CF was detected from early adolescence (~13 years) and increased with age (rs=0.67, P<0.001). Conclusions Our results indicate that early onset emphysema detected by densitometry on chest MDCT is a characteristic pathology that contributes to airflow limitation and may serve as a novel endpoint for monitoring lung disease in CF. PMID:23991177
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damilakis, John; Tzedakis, Antonis; Perisinakis, Kostas
Purpose: Current methods for the estimation of conceptus dose from multidetector CT (MDCT) examinations performed on the mother provide dose data for typical protocols with a fixed scan length. However, modified low-dose imaging protocols are frequently used during pregnancy. The purpose of the current study was to develop a method for the estimation of conceptus dose from any MDCT examination of the trunk performed during all stages of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study to model the Siemens Sensation 16 and Sensation 64 MDCT scanners. Four mathematical phantoms were used, simulatingmore » women at 0, 3, 6, and 9 months of gestation. The contribution to the conceptus dose from single simulated scans was obtained at various positions across the phantoms. To investigate the effect of maternal body size and conceptus depth on conceptus dose, phantoms of different sizes were produced by adding layers of adipose tissue around the trunk of the mathematical phantoms. To verify MCNP results, conceptus dose measurements were carried out by means of three physical anthropomorphic phantoms, simulating pregnancy at 0, 3, and 6 months of gestation and thermoluminescence dosimetry (TLD) crystals. Results: The results consist of Monte Carlo-generated normalized conceptus dose coefficients for single scans across the four mathematical phantoms. These coefficients were defined as the conceptus dose contribution from a single scan divided by the CTDI free-in-air measured with identical scanning parameters. Data have been produced to take into account the effect of maternal body size and conceptus position variations on conceptus dose. Conceptus doses measured with TLD crystals showed a difference of up to 19% compared to those estimated by mathematical simulations. Conclusions: Estimation of conceptus doses from MDCT examinations of the trunk performed on pregnant patients during all stages of gestation can be made using the method developed in the current study.« less
Slówko, Witold; Wiatrowski, Artur; Krysztof, Michał
2018-01-01
The paper considers some major problems of adapting the multi-detector method for three-dimensional (3D) imaging of wet bio-medical samples in Variable Pressure/Environmental Scanning Electron Microscope (VP/ESEM). The described method pertains to "single-view techniques", which to create the 3D surface model utilise a sequence of 2D SEM images captured from a single view point (along the electron beam axis) but illuminated from four directions. The basis of the method and requirements resulting from them are given for the detector systems of secondary (SE) and backscattered electrons (BSE), as well as designs of the systems which could work in variable conditions. The problems of SE detection with application of the Pressure Limiting Aperture (PLA) as the signal collector are discussed with respect to secondary electron backscattering by a gaseous environment. However, the authors' attention is turned mainly to the directional BSE detection, realized in two ways. The high take off angle BSE were captured through PLA with use of the quadruple semiconductor detector placed inside the intermediate chamber, while BSE starting at lower angles were detected by the four-folded ionization device working in the sample chamber environment. The latter relied on a conversion of highly energetic BSE into low energetic SE generated on walls and a gaseous environment of the deep discharge gap oriented along the BSE velocity direction. The converted BSE signal was amplified in an ionising avalanche developed in the electric field arranged transversally to the gap. The detector system operation is illustrated with numerous computer simulations and examples of experiments and 3D images. The latter were conducted in a JSM 840 microscope with its combined detector-vacuum equipment which could extend capabilities of this high vacuum instrument toward elevated pressures (over 1kPa) and environmental conditions. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Bezzi, Mario; Bruni, Antonio
2011-02-15
We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findingsmore » and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.« less
Utsunomiya, Hiroto; Yamamoto, Hideya; Kunita, Eiji; Kitagawa, Toshiro; Ohashi, Norihiko; Oka, Toshiharu; Yamazato, Ryo; Horiguchi, Jun; Kihara, Yasuki
2010-11-01
We examined the association of aortic valve calcification (AVC) and mitral annular calcification (MAC) to coronary atherosclerosis using 64-multidetector computed tomography (MDCT). Valvular calcification is considered a manifestation of atherosclerosis. The impact of multiple heart valve calcium deposits on the distribution and characteristics of coronary plaque is unknown. We evaluated 322 patients referred for 64-MDCT, and assessed valvular calcification and the extent of calcified (CAP), mixed (MCAP), and noncalcified coronary atherosclerotic plaque (NCAP) in accordance with the 17-coronary segments model. We assessed the vulnerable characteristics of coronary plaque with positive remodeling, low-density plaque (CT density ≤38 Hounsfield units), and the presence of adjacent spotty calcification. In 49 patients with both AVC and MAC, the segment numbers of CAP and MCAP were larger than in those with a lack of valvular calcification and an isolated AVC (p<0.001 for both). Multivariate analyses revealed that a combined presence of AVC and MAC was independently associated with the presence (odds ratio [OR] 9.36, 95% confidence interval [95%CI] 1.55-56.53, p=0.015) and extent (β-estimate 1.86, p<0.001) of overall coronary plaque. When stratified by plaque composition, it was associated with the extent of CAP (β-estimate 1.77, p<0.001) and MCAP (β-estimate 1.04, p<0.001), but not with NCAP. Moreover, it was also related to the presence of coronary plaque with all three vulnerable characteristics (OR 4.87, 95%CI 1.85-12.83, p=0.001). The combined presence of AVC and MAC is highly associated with the presence, extent, and vulnerable characteristics of coronary plaque identified by 64-MDCT. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Ho, Lisa M; Nelson, Rendon C; Delong, David M
2007-05-01
To prospectively evaluate the use of lean body weight (LBW) as the main determinant of the volume and rate of contrast material administration during multi-detector row computed tomography of the liver. This HIPAA-compliant study had institutional review board approval. All patients gave written informed consent. Four protocols were compared. Standard protocol involved 125 mL of iopamidol injected at 4 mL/sec. Total body weight (TBW) protocol involved 0.7 g iodine per kilogram of TBW. Calculated LBW and measured LBW protocols involved 0.86 g of iodine per kilogram and 0.92 g of iodine per kilogram calculated or measured LBW for men and women, respectively. Injection rate used for the three experimental protocols was determined proportionally on the basis of the calculated volume of contrast material. Postcontrast attenuation measurements during portal venous phase were obtained in liver, portal vein, and aorta for each group and were summed for each patient. Patient-to-patient enhancement variability in same group was measured with Levene test. Two-tailed t test was used to compare the three experimental protocols with the standard protocol. Data analysis was performed in 101 patients (25 or 26 patients per group), including 56 men and 45 women (mean age, 53 years). Average summed attenuation values for standard, TBW, calculated LBW, and measured LBW protocols were 419 HU +/- 50 (standard deviation), 443 HU +/- 51, 433 HU +/- 50, and 426 HU +/- 33, respectively (P = not significant for all). Levene test results for summed attenuation data for standard, TBW, calculated LBW, and measured LBW protocols were 40 +/- 29, 38 +/- 33 (P = .83), 35 +/- 35 (P = .56), and 26 +/- 19 (P = .05), respectively. By excluding highly variable but poorly perfused adipose tissue from calculation of contrast medium dose, the measured LBW protocol may lessen patient-to-patient enhancement variability while maintaining satisfactory hepatic and vascular enhancement.
Holalkere, N-S; Matthes, K; Kalva, S P; Brugge, W R; Sahani, D V
2011-01-01
Objective In this study we aimed to assess the image quality and degree of vascular enhancement using low-concentration contrast media (LCCM) (300 mg I ml–1) and high-concentration contrast media (HCCM) (370 mg I ml–1) on 64-slice multidetector row CT (MDCT) abdominal CT angiography (CTA). In addition, we aimed to study the feasibility of using HCCM with a reduced total iodine dose. Methods CTA of the abdomen on a 64-slice MDCT was performed on 15 anaesthetised pigs. Study pigs were divided into three groups of five each based on the iodine concentration and dose received: Group A (LCCM; 300 mg I ml–1), Group B (HCCM; 370 mg I ml–1) and Group C HCCM with 20% less iodine dose. The total iodine injected was kept constant (600 mg kg–1) in Groups A and B. Qualitative and quantitative analyses were performed to study and compare each group for image quality, visibility of the branch order of the superior mesenteric artery (SMA), artefacts, degree of enhancement in the aorta and main stem arteries and uniformity of enhancement in the aorta. Groups were compared using the analysis of variance test. Results The image quality of 64-slice MDCT angiography was excellent with a mean score of 4.63 and confident visualisation of the third to fifth order branches of the SMA in all groups. Group B demonstrated superior vascular enhancement, as compared with Groups A and C (p≤0.05). Uniform aortic enhancement was achieved with the use of LCCM and HCCM with 20% less iodine dose. Conclusion 64-slice MDCT angiography of the abdomen was of excellent quality. HCCM improves contrast enhancement and overall CTA image quality and allows the iodine dose to be reduced. PMID:21081582
2011-01-01
Background Diagnosis of extracardiac intrathoracic vascular anomalies is of clinical importance, but remains challenging. Traditional imaging modalities, such as radiography, echocardiography, and angiography, are inherently limited by the difficulties of a 2-dimensional approach to a 3-dimensional object. We postulated that accurate characterization of malformations of the aorta would benefit from 3-dimensional assessment. Therefore, multidetector-row computed tomography (MDCT) was chosen as a 3-dimensional, new, and noninvasive imaging technique. The purpose of this study was to evaluate patients with 2 common diseases of the intrathoracic aorta, either patent ductus arteriosus or vascular ring anomaly, by contrast-enhanced 64-row computed tomography. Results Electrocardiography (ECG)-gated and thoracic nongated MDCT images were reviewed in identified cases of either a patent ductus arteriosus or vascular ring anomaly. Ductal size and morphology were determined in 6 dogs that underwent ECG-gated MDCT. Vascular ring anomalies were characterized in 7 dogs and 3 cats by ECG-gated MDCT or by a nongated thoracic standard protocol. Cardiac ECG-gated MDCT clearly displayed the morphology, length, and caliber of the patent ductus arteriosus in 6 affected dogs. Persistent right aortic arch was identified in 10 animals, 8 of which showed a coexisting aberrant left subclavian artery. A mild dilation of the proximal portion of the aberrant subclavian artery near its origin of the aorta was present in 4 dogs, and a diverticulum analogous to the human Kommerell's diverticulum was present in 2 cats. Conclusions Contrast-enhanced MDCT imaging of thoracic anomalies gives valuable information about the exact aortic arch configuration. Furthermore, MDCT was able to characterize the vascular branching patterns in dogs and cats with a persistent right aortic arch and the morphology and size of the patent ductus arteriosus in affected dogs. This additional information can be of help with regard to improved diagnoses of thoracic anomalies and the planning of surgical interventions. PMID:21943366
Pulmonary involvement in rheumatoid arthritis: multidetector computed tomography findings.
Yuksekkaya, Ruken; Celikyay, Fatih; Yilmaz, Ayse; Arslan, Sule; Inanir, Ahmet; Inonu, Handan; Deniz, Caglar
2013-12-01
Pulmonary involvement in rheumatoid arthritis (RA) is common and encompasses a large spectrum of disease with different treatment options and prognoses. Therefore, assessment of these patients with multidetector computed tomography (MDCT) is vital. To evaluate the MDCT pulmonary findings of patients with RA and to compare these findings with the clinical status. Chest MDCT scans of 85 patients with RA between 2006-2012 were assessed. One patient with a pulmonary infection was excluded from the study. MDCT findings and distribution of the CT findings were examined, and patients were classified according to the predominant CT pattern. The pulmonary function test (PFT) results and categories, demographic characteristics, and clinical status of some of the patients for whom the results were obtained were evaluated, and the CT findings, PFT results, demographic characteristics, and clinical status were compared. The study group consisted of 20 men (mean age, 58.1 years ± 13.1; range, 15-77 years) and 64 women (mean age, 55.3 years ± 11.5; range, 30-84 years). The most frequent findings were nodules (78.6%) and pleural thickening (48.8%). The most common CT patterns were follicular bronchiolitis (FB) in 28 (33.3%) patients and nodular disease (ND) in 12 (14.3%) others. There was no statistically significant difference between the CT findings and PFT results, and no statistically significant difference was noted in the CT findings between symptomatic and asymptomatic patients. In addition, there were some patients who exhibited no symptoms and/or had abnormal PFT results but had abnormal CT findings. Rheumatoid arthritis is associated with a high frequency of CT findings and CT patterns, with nodules and pleural thickening being the most common CT findings and FB and ND being the most common CT patterns. MDCT identification of patients with RA may be helpful in the evaluation of pulmonary disease, even in patients without symptoms and PFT abnormalities.
Aortic Arch Width and Cardiovascular Disease in Men and Women in the Community.
Chuang, Michael L; Gona, Philimon N; Qazi, Saadia; Musgrave, Rebecca M; Fox, Caroline S; Massaro, Joseph M; Hoffmann, Udo; O'Donnell, Christopher J
2018-06-16
We sought to determine whether increased aortic arch width (AAW) adds to standard Framingham risk factors and coronary artery calcium (CAC) for prediction of incident adverse cardiovascular disease (CVD) events in community-dwelling adults. A total of 3026 Framingham Heart Study Offspring and Third Generation cohort participants underwent noncontrast multidetector computed tomography from 2002 to 2005 to quantify CAC. We measured AAW as the distance between the centroids of the ascending and descending thoracic aorta, at the level of main pulmonary artery bifurcation or the right pulmonary artery. We determined sex, age group, and body size specific cut points for high (≥90th percentile) AAW from a healthy referent group (N=1471) and dichotomized AAW as high or not high across all study participants. Clinical covariates were obtained at Offspring cycle 7 (1998-2001) or Third Generation cycle 1 (2002-2005) examinations. The primary CVD outcome was a composite of myocardial infarction, coronary insufficiency, cerebrovascular accident, first hospitalization for heart failure, or CVD death. Cox proportional hazards models were used to estimate hazard ratio of high AAW on time-to-incident CVD after adjustment for Framingham risk factors and CAC. Net reclassification improvement was used to assess the effect of adding AAW to the baseline Framingham risk factor+CAC model. A total of 2826 participants (aged 51±11 years, 48% women) had complete covariates and were free of CVD at multidetector computed tomography. Over a median 8.9 years of follow-up, there were 135 incident CVD events. High AAW was independently predictive of CVD events (hazard ratio, 1.55; P =0.032) and appropriately reclassified participants at risk: net reclassification improvement, 0.31 (95% confidence interval, 0.15-0.48). AAW augments traditional CVD risk factors and CAC for prediction of incident adverse CVD events among community-dwelling adults. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Qi, Rui; Zhou, Xianping; Yu, Jianqun; Chen, Weixia; Li, Zhenlin; Zhang, Chunle
2012-08-01
The present paper is aimed to observe the lateral attachment of the renal fascia (RF) in vivo with multidetector computed tomography (MDCT) scanning, and to discuss its diagnostic value. 121 healthy adults were adopted into this experiment. All images were obtained with MDCT and double phase enhancement scanning. Then we observed the lateral attachment of RF. In addition, we mad a fresh body specimen as anatomical basis. The study found that above the renal hilar plane (RHP), the anterior renal fascia laterally fused with the peritoneum of the liver on the right and the peritoneum of the spleen on the left,and the posterior renal fascia fused with the subdiaphragmatic fascia. The lateral attachment of the RF at the RHP and the lower renal pole(LRP)is divided into three types. The RF in Type I is about 47.9% (58/121) at the left RHP, while about 33.9% (41/121) at the right RHP. At the LRP of the kidney is about 55.3% (67/121) on the left, and about 42.1% (51/121) on the right. The RF in Type I is about 38.8% (47/121) on the left side at the RHP, about 26.4% (32/121) on the right side. At the LRP, left side about 27.3% (33/121), right side about 13.3%(16/121). The RF in Type III at the RHP is 13.3% (16/121) on the left side, and on the right side is about 39.7% (48/121). At the LRP, it is about 17.4% (21/121) on the left side, and about 44.6% (54/121) on the right side. MDCT can display the lateral attachment of the RF better as well as the outside connection of the retroperitoneal space.
Low-contrast detectability in volume rendering: a phantom study on multidetector-row spiral CT data.
Shin, Hoen-Oh; Falck, Christian V; Galanski, Michael
2004-02-01
To cope with the increasing amount of CT data, there is growing interest in direct volume-rendering techniques (VRT) as a diagnostic tool. The aim of this phantom study was to analyze the low-contrast detectability (LCD) of VRT compared with multi-planar reformations (MPR). Soft tissue lesions were simulated by spheres of different diameters (3-8 mm). The average lesion density was 15 HU compared with a background density of 35 HU. Two different CT protocols with 40 and 150 mAs were performed on a multi-detector row CT. The scanning parameters were as following: 140 kV; 2x0.5-mm slice collimation; pitch 2 (table movement per rotation/single slice collimation), and reconstruction with 0.5-mm slice thickness at 0.5-mm interval. A B30 kernel was used for reconstruction. The VRT was performed by mapping Hounsfield values to gray levels equal to a CT window (center: 60 HU; window: 370 HU ). A linear ramp was applied for the opacity transfer function varying the maximum opacity between 0.1 and 1.0. A statistical method based on the Rose model was used to calculate the detection threshold depending on lesion size and image noise. Additionally, clinical data of 2 patients with three liver lesions of different sizes and density were evaluated. In VRT, LCD was most dependent on object size. Regarding lesions larger than 5 mm, VRT is significantly superior to MPR (p<0.05) for all opacity settings. In lesions sized 3-5 mm a maximum opacity level approximately 40-50% showed a near equivalent detectability in VRT and MPR. For higher opacity levels VRT was superior to MPR. Only for 3-mm lesions MPR performed slightly better in low-contrast detectability (p<0.05). Compared with MPR, VRT shows similar performance in LCD. Due to noise suppression effects, it is suited for visualization of data with high noise content.
Effect of certificate of need law on emergency department length of stay.
Paul, Jomon Aliyas; Ni, Huan; Bagchi, Aniruddha
2014-10-01
The impact of the Certificate of Need (CON) law on Emergency Department (ED) care remains elusive in the academic literature. We study the impact of CON law on ED Length of Stay (LOS). We examine ED LOS to detect any statistically significant difference between CON and non-CON states. We then estimate the effects of CON law on ED LOS by treating CON as an exogenous (endogenous) variable. We find that the CON legislation positively impacts ED care by reducing ED LOS (95% confidence interval [CI] -61.3 to -10.3), and we can't reject the hypothesis that the CON legislation can be treated as an exogenous variable in our model. An increase in the stringency of the CON law (measured by the threshold on equipment expenditure that is subject to a CON review) tends to diminish this positive impact on ED LOS (95% CI 9.9-68.0). The party affiliation of the Governor (95% CI 10.3-37.5), the political environment as a function of the agreement on voting between state senators (95% CI-64.8 to -12.9), proportion of young population (0-17 years) when compared with the elderly (>65 years) (95% CI-2299.7 to -184.1), proportion of population covered by privately purchased insurance (95% CI-819.3 to -59.9), etc., are found to significantly impact ED LOS in a state. This study provides a better understanding of the impact of CON law on ED care, which extends the previous literature that has mainly focused on CON effects on inpatient care. Copyright © 2014 Elsevier Inc. All rights reserved.
Increased blood pressure later in life may be associated with perinatal n-3 fatty acid deficiency.
Armitage, James A; Pearce, Adrian D; Sinclair, Andrew J; Vingrys, Algis J; Weisinger, Richard S; Weisinger, Harrison S
2003-04-01
Hypertension is a major risk factor for cardiovascular and cerebrovascular disease. Previous work in both animals and humans with high blood pressure has demonstrated the antihypertensive effects of n-3 polyunsaturated fatty acids (PUFA), although it is not known whether these nutrients are effective in preventing hypertension. The predominant n-3 PUFA in the mammalian nervous system, docosahexaenoic acid (DHA), is deposited into synaptic membranes at a high rate during the perinatal period, and recent observations indicate that the perinatal environment is important for the normal development of blood pressure control. This study investigated the importance of perinatal n-3 PUFA supply in the control of blood pressure in adult Sprague-Dawley rats. Pregnant rat dams were fed semisynthetic diets that were either deficient in (DEF) or supplemented with (CON) n-3 PUFA. Offspring were fed the same diets as their mothers until 9 wk; then, half of the rats from each group were crossed over to the opposite diet creating four groups, i.e., CON-CON; CON-DEF; DEF-DEF, DEF-CON. Mean arterial blood pressures (MAP) were measured directly, at 33 wk of age, by cannulation of the femoral artery. The phospholipid fatty acid profile of the hypothalamic region was determined by capillary gas-liquid chromatography. The tissue phospholipid fatty acid profile reflected the diet that the rats were consuming at the time of testing. Both groups receiving DEF after 9 wk of age (i.e., DEF-DEF and CON-DEF) had similar profiles with a reduction in DHA levels of 30%, compared with rats receiving CON (i.e., CON-CON and DEF-CON). DEF-DEF rats had significantly raised MAP compared with all other groups, with differences as great as 17 mm Hg. DEF-CON rats had raised MAP compared with CON-CON rats, and DEF-DEF rats had higher MAP than CON-DEF rats, despite the fact that their respective fatty acid profiles were not different. These findings indicate that inadequate levels of DHA in the perinatal period are associated with altered blood pressure control in later life. The way in which these long-term effects are produced remains to be elucidated.
Graham, R N J
2012-01-01
With the increasing tempo of military conflicts in the last decade, much has been learnt about imaging battlefield casualties in the acute setting. Ultrasound in the form of focused abdominal sonography in trauma (FAST) has proven invaluable in emergency triage of patients for immediate surgery. Multidetector CT allows accurate determination of battlefield trauma injuries. It permits the surgeons and anaesthetists to plan their interventions more thoroughly and to be made aware of clinically occult injuries. There are common injury patterns associated with blast injury, gunshot wounds and blunt trauma. While this body of knowledge is most applicable to the battlefield, there are parallels with peacetime radiology, particularly in terrorist attacks and industrial accidents. This pictorial review is based on the experiences of a UK radiologist deployed in Afghanistan in 2010. PMID:22806621
Automated software configuration in the MONSOON system
NASA Astrophysics Data System (ADS)
Daly, Philip N.; Buchholz, Nick C.; Moore, Peter C.
2004-09-01
MONSOON is the next generation OUV-IR controller project being developed at NOAO. The design is flexible, emphasizing code re-use, maintainability and scalability as key factors. The software needs to support widely divergent detector systems ranging from multi-chip mosaics (for LSST, QUOTA, ODI and NEWFIRM) down to large single or multi-detector laboratory development systems. In order for this flexibility to be effective and safe, the software must be able to configure itself to the requirements of the attached detector system at startup. The basic building block of all MONSOON systems is the PAN-DHE pair which make up a single data acquisition node. In this paper we discuss the software solutions used in the automatic PAN configuration system.
Addai, Theodore; Kola, Monahar; Raqeem, Muhammad Wajih; Barsamyan, Sergey; Mirrakhimov, Aibek E.
2016-01-01
An 82-year-old female with history of hyperlipidemia and hypertension presented to the clinic with chief complaint of nonradiating chest tightness accompanied by exertional dyspnea. Cardiac catheterization showed the absence of left coronary system; the entire coronary system originated from the right aortic sinus as a common trunk which then gave off the right coronary artery and the left main coronary artery. Cardiac catheterization demonstrated also another rare coronary anomaly: dual left anterior descending artery. Patient underwent percutaneous coronary intervention and subsequent multidetector computed tomography angiography confirmed the above angiography findings. Patient was subsequently discharged home on double antiplatelet therapy with aspirin and clopidogrel and has been asymptomatic since then. PMID:27293909
Abchee, Antoine; Saade, Charbel; Al-Mohiy, Hussain; El-Merhi, Fadi
2014-01-01
Congenital vascular anomalies of the venous drainage in the chest affect both cardiac and non-cardiac structures. Collateral venous drainage from the left subclavian vein to the great cardiac vein is a rare venous drainage pattern. These anomalies present a diagnostic challenge. Multi-detector computed tomography (MDCT) is useful in the diagnosis and treatment planning of these clinically complex disorders. We present a case report of an 18-year-old Caucasian male who came to our institute for evaluation of venous drainage patterns to the heart. We describe the contrast technique of bilateral dual injection MDCT venography and the imaging features of the venous drainage patterns to the heart. PMID:25379351
Abchee, Antoine; Saade, Charbel; Al-Mohiy, Hussain; El-Merhi, Fadi
2014-01-01
Congenital vascular anomalies of the venous drainage in the chest affect both cardiac and non-cardiac structures. Collateral venous drainage from the left subclavian vein to the great cardiac vein is a rare venous drainage pattern. These anomalies present a diagnostic challenge. Multi-detector computed tomography (MDCT) is useful in the diagnosis and treatment planning of these clinically complex disorders. We present a case report of an 18-year-old Caucasian male who came to our institute for evaluation of venous drainage patterns to the heart. We describe the contrast technique of bilateral dual injection MDCT venography and the imaging features of the venous drainage patterns to the heart.
Imaging in chronic obstructive pulmonary disease.
Shaker, Saher B; Dirksen, Asger; Bach, Karen S; Mortensen, Jann
2007-06-01
Chronic obstructive pulmonary disease (COPD) is divided into pulmonary emphysema and chronic bronchitis (CB). Emphysema is defined patho-anatomically as "permanent enlargement of airspaces distal to the terminal bronchiole, accompanied by the destruction of their walls, and without obvious fibrosis" (1). These lesions are readily identified and quantitated using computed tomography (CT), whereas the accompanying hyperinflation is best detected on plain chest X-ray, especially in advanced disease. The diagnosis of CB is clinical and relies on the presence of productive cough for 3 months in 2 or more successive years. The pathological changes of mucosal inflammation and bronchial wall thickening have been more difficult to identify with available imaging techniques. However, recent studies using Multi-detector row CT (MDCT) reported more reproducible assessment of air wall thickening.
Estimation of regional lung expansion via 3D image registration
NASA Astrophysics Data System (ADS)
Pan, Yan; Kumar, Dinesh; Hoffman, Eric A.; Christensen, Gary E.; McLennan, Geoffrey; Song, Joo Hyun; Ross, Alan; Simon, Brett A.; Reinhardt, Joseph M.
2005-04-01
A method is described to estimate regional lung expansion and related biomechanical parameters using multiple CT images of the lungs, acquired at different inflation levels. In this study, the lungs of two sheep were imaged utilizing a multi-detector row CT at different lung inflations in the prone and supine positions. Using the lung surfaces and the airway branch points for guidance, a 3D inverse consistent image registration procedure was used to match different lung volumes at each orientation. The registration was validated using a set of implanted metal markers. After registration, the Jacobian of the deformation field was computed to express regional expansion or contraction. The regional lung expansion at different pressures and different orientations are compared.
NASA Astrophysics Data System (ADS)
Pirrone, S.; Politi, G.; Wieleczko, J. P.; Gnoffo, B.; De Filippo, E.; La Commara, M.; Russotto, P.; Trimarchi, M.; Vigilante, M.; Ademard, G.; Auditore, L.; Beck, C.; Bercenau, I.; Bonnet, E.; Borderie, B.; Cardella, G.; Chibihi, A.; Colonna, M.; D'Onofrio, A.; Frankland, J. D.; Lanzalone, G.; Lautesse, P.; Lebhertz, D.; Le Neidre, N.; Lombardo, I.; Mazurek, K.; Pagano, A.; Pagano, E. V.; Papa, M.; Piasecki, E.; Porto, F.; Quattrocchi, L.; Rizzo, F.; Spadaccini, G.; Trifirò, A.; Verde, G.
2017-09-01
The study of the decay modes competition of the compound systems produced in the collisions ^{78}{Kr} + ^{40}{Ca} and ^{86}{Kr} + ^{48}{Ca} at 10MeV/A is presented. In particular, the N / Z entrance channel influence on the decay paths of the compound systems, directly connected to the isospin influence, is investigated. The experiment was performed at the INFN Laboratori Nazionali del Sud (LNS) in Catania by using the 4 π multi-detector CHIMERA. Charge, mass, angular distributions and kinematical features of the reaction products were studied. The analysis shows some differences in the contribution arising from the various reaction mechanisms for the neutron-poor and neutron-rich systems.
Nuclear stopping in central Xe+Sn collisions: Confrontation with experimental data
NASA Astrophysics Data System (ADS)
Rajni, Vermani, Yogesh K.
2018-05-01
The influence of symmetry energy and cross section on nuclear stopping is studied in central 54129Xe+50 120Sn Sn collisions at Fermi energies (Elab≈ 20-100 MeV/nucleon). The analysis is conducted using isospin dependent quantum molecular dynamics (IQMD) transport model. Model calculations are done using reduced isospin dependent nucleon-nucleon cross section (σiso) and isospin independent cross section (σnoiso). Calculations using the two versions of cross section are analyzed with and without symmetry energy (Esym). The results are then compared with the experimental data taken with 4π multidetector INDRA. From this comparison, we conclude that nuclear stopping and related production of light charged particles (LCPs) are strongly influenced by isospin dependence of nucleon-nucleon cross section.
PHACES syndrome associated with carcinoid endobronchial tumor.
Mama, Nadia; H'mida, Dorra; Lahmar, Imen; Yacoubi, Mohamed Tahar; Tlili-Graiess, Kalthoum
2014-05-01
PHACES syndrome consists of the constellation of manifestations including posterior fossa anomalies of the brain (most commonly Dandy-Walker malformations), hemangiomas of the face and scalp, arterial abnormalities, cardiac defects, eye anomalies and sternal defects. We present a case with a possible PHACES syndrome including sternal cleft and supraumbilical raphé, precordial skin tag, persistent left superior vena cava and subtle narrowing of the aorta with an endobronchial carcinoid tumor. All these anomalies were discovered on chest multi-detector CT. This is a unique case of PHACES syndrome associated with carcinoid tumor. Review of the literature revealed 3 cases of PHACES syndrome with glial tumor. The authors tried to find the relationship between PHACES syndrome and carcinoid tumors or gliomas, which all derive from the neural crest cells.
State deregulation and Medicare costs for acute cardiac care.
Ho, Vivian; Ku-Goto, Meei-Hsiang
2013-04-01
Past literature suggests that Certificate of Need (CON) regulations for cardiac care were ineffective in improving quality, but less is known about the effect of CON on patient costs. We analyzed Medicare data for 1991-2002 to test whether states that dropped CON experienced changes in costs or reimbursements for coronary artery bypass graft (CABG) surgery or percutaneous coronary interventions. We found that states that dropped CON experienced lower costs per patient for CABG but not for percutaneous coronary intervention. Average Medicare reimbursement was lower for both procedures in states that dropped CON. The cost savings from removing CON regulations slightly exceed the total fixed costs of new CABG facilities that entered after deregulation. Assuming continued cost savings past 2002, the savings from deregulating CABG surgery outweigh the fixed costs of new entry. Thus, CON regulations for CABG may not be justified in terms of either improving quality or controlling cost growth.
9 CFR 319.301 - Chili con carne with beans.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Chili con carne with beans. 319.301 Section 319.301 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... Dehydrated Meat Food Products § 319.301 Chili con carne with beans. Chili con carne with beans shall contain...
9 CFR 319.301 - Chili con carne with beans.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Chili con carne with beans. 319.301 Section 319.301 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... Dehydrated Meat Food Products § 319.301 Chili con carne with beans. Chili con carne with beans shall contain...
9 CFR 319.301 - Chili con carne with beans.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Chili con carne with beans. 319.301 Section 319.301 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... Dehydrated Meat Food Products § 319.301 Chili con carne with beans. Chili con carne with beans shall contain...
9 CFR 319.301 - Chili con carne with beans.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Chili con carne with beans. 319.301 Section 319.301 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... Dehydrated Meat Food Products § 319.301 Chili con carne with beans. Chili con carne with beans shall contain...
9 CFR 319.300 - Chili con carne.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Chili con carne. 319.300 Section 319.300 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY... Products § 319.300 Chili con carne. “Chili con carne” shall contain not less than 40 percent of meat...
9 CFR 319.301 - Chili con carne with beans.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Chili con carne with beans. 319.301 Section 319.301 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... Dehydrated Meat Food Products § 319.301 Chili con carne with beans. Chili con carne with beans shall contain...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Wen-wen; Yu, Jia-ying; Xu, Huai-long
2011-10-22
Highlights: {yields} ConA induces cancer cell death targeting apoptosis and autophagy. {yields} ConA inhibits cancer cell angiogenesis. {yields} ConA is utilized in pre-clinical and clinical trials. -- Abstract: Concanavalin A (ConA), a Ca{sup 2+}/Mn{sup 2+}-dependent and mannose/glucose-binding legume lectin, has drawn a rising attention for its remarkable anti-proliferative and anti-tumor activities to a variety of cancer cells. ConA induces programmed cell death via mitochondria-mediated, P73-Foxo1a-Bim apoptosis and BNIP3-mediated mitochondrial autophagy. Through IKK-NF-{kappa}B-COX-2, SHP-2-MEK-1-ERK, and SHP-2-Ras-ERK anti-angiogenic pathways, ConA would inhibit cancer cell survival. In addition, ConA stimulates cell immunity and generates an immune memory, resisting to the same genotypic tumor.more » These biological findings shed light on new perspectives of ConA as a potential anti-neoplastic agent targeting apoptosis, autophagy and anti-angiogenesis in pre-clinical or clinical trials for cancer therapeutics.« less
Xu, Dan-Feng; Zhang, Shen; Wang, Cun-Zhou; Li, Jun; Qu, Chuang-Yu; Cui, Xin-Gang; Zhao, Sheng-Jia
2012-08-01
The aim of the study was to assess the efficacy of low-frequency electrotherapy (LFE) for female patients with early-stage detrusor underactivity (DUA) due to neuromuscular deficiency. A total of 102 female patients were divided randomly into four groups: LFE-NC (normal compliance), LFE-LC (low compliance), CON (control)-NC and CON-LC. Patients in the LFE-NC and LFE-LC groups received LFE, and those in the CON-NC and CON-LC groups received conservative treatment. Urodynamic evaluation was performed before and after treatment. After treatment, 82 % of the LFE-NC regained detrusor contractility, whereas only 2 (8 %) of the CON-NC had normal detrusor contraction. None of LFE-LC or CON-LC regained detrusor contractility (p < 0.01). The per cent of LFE-NC who relied on catheterization for bladder emptying decreased by 43 % (p < 0.01). Those in the LFE-LC, CON-NC and CON-LC groups decreased by only 4, 12 or 0 % (p > 0.05). LFE was more effective for DUA patients with normal compliance; these patients benefited from LFE, but DUA patients with low compliance did not.
Rojo-Trejo, María Elena; Rangel Peniche, Diana Beatriz; Arellano Jiménez, María Del Rocío; Sabath Silva, Ernesto Francisco
2016-06-30
Introducción: el bajo peso al nacer (BPN) es un factor de riesgo para desarrollar obesidad en la vida adulta.Objetivo: evaluar diferencias en la composición corporal de niños de entre 8 y 10 años de edad con y sin antecedente de BPN.Métodos: fue un estudio observacional, transversal comparativo. Participaron 112 niños (95 con adecuado peso al nacer [APN] y 17 con BPN). Se realizó antropometría (peso, talla, circunferencias de cintura y cadera, pliegue cutáneo de tríceps [PCT] y subescapular [PCSE]).Resultados: se encontró una prevalencia combinada del 41% para sobrepeso y obesidad en ambos grupos de estudio. El porcentaje de grasa corporal total fue menor en las niñas con BPN (no significativo); sin embargo, el indicador PCT-PCSE fue significativamente más alto (p = 0,04) que el de las niñas con APN. En contra de lo esperado, al estratificar según porcentaje de grasa y peso al nacer, se encontró que el grupo con BPN presentó un porcentaje de grasa bajo (p < 0,05) en comparación con el grupo de APN, siendo 6 veces mayor la posibilidad de que un niño con BPN presente porcentaje de grasa total bajo a esta edad.Conclusiones: a estas edades no se encontró mayor porcentaje de grasa en el grupo con BPN en comparación con el de APN; sin embargo, las niñas con BPN presentaron mayor deposición de grasa troncal que las de APN. La deposición de grasa es un indicador que hay que considerar, y no únicamente el índice de masa corporal, en la evaluación nutricia infantil.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Qi; Xu, Xi, E-mail: xuxi@njust.edu.cn; Yang,
Salecan, a water-soluble extracellular β-glucan produced by Agrobacterium sp. ZX09, has been reported to exhibit a wide range of biological effects. The aims of the present study were to investigate the protective effect of salecan against Concanavalin A (ConA)-induced hepatitis, a well-established animal model of immune-mediated liver injury, and to search for possible mechanisms. C57BL/6 mice were pretreated with salecan followed by ConA injection. Salecan treatment significantly reduced ConA-induced acute liver injury, and suppressed the expression and secretion of inflammatory cytokines including interferon (IFN)-γ, interleukin (IL)-6 and IL-1β in ConA-induced liver injury model. The high expression levels of chemokines andmore » adhesion molecules such as MIP-1α, MIP-1β, ICAM-1, MCP-1 and RANTES in the liver induced by ConA were also down-regulated after salecan treatment. Salecan inhibited the infiltration and activation of inflammatory cells, especially T cells, in the liver induced by ConA. Moreover, salecan reversed the metabolic profiles of ConA-treated mice towards the control group by partly recovering the metabolic perturbations induced by ConA. Our results suggest the preventive and therapeutic potential of salecan in immune-mediated hepatitis. - Highlights: • Salecan treatment significantly reduced ConA-induced liver injury. • Salecan suppressed the expression and secretion of inflammatory cytokines. • Salecan decreased the expression of chemokines and adhesion molecules in liver. • Salecan inhibited the infiltration and activation of T cells induced by ConA. • Salecan partly recovered the metabolic perturbations induced by ConA.« less
Effect of Maternal Obesity on Fetal Growth and Expression of Placental Fatty Acid Transporters.
Ye, Kui; Li, Li; Zhang, Dan; Li, Yi; Wang, Hai Qing; Lai, Han Lin; Hu, Chuan Lai
2017-12-15
To explore the effects of maternal high-fat (HF) diet-induced obesity on fetal growth and the expression of placental nutrient transporters. Maternal obesity was established in rats by 8 weeks of pre-pregnancy fed HF diet, while rats in the control group were fed normal (CON) diet. Diet-induced obesity (DIO) rats and diet-induced obesity-resistant (DIR) rats were selected according to body weight gain over this period. After copulation, the CON rats were divided into two groups: switched to HF diet (CON-HF group) or maintained on the CON diet (CON-CON group). The DIO rats and DIR rats were maintained on the HF diet throughout pregnancy. Pregnant rats were euthanized at day 21 gestation, fetal and placental weights were recorded, and placental tissue was collected. Reverse transcription-polymerase chain reaction was used to determine mRNA expression of placental nutrient transporters. Protein expression was determined by Western blot. Average fetal weight of DIO dams was reduced by 6.9%, and the placentas of CON-HF and DIO dams were significantly heavier than the placentas of CON-CON and DIR dams at day 21 of gestation (p<0.05). The fetal/placental weight ratio of DIO dams was significantly reduced compared with the fetal/placental weight ratio of CON-CON dams (p<0.05). The mRNA expression of GLUT-1 and SNAT-2 were not significantly different between groups. The mRNA and protein expression levels of CD36, FATP-1, and FATP-4 in DIO dams were decreased significantly (p<0.05). Maternal obesity induced by a HF diet led to intrauterine growth retardation and down-regulated the expression of placental fatty acid transporters.
The Columbia Thyroid Eye Disease-Compressive Optic Neuropathy Formula.
Callahan, Alison B; Campbell, Ashley A; Oropesa, Susel; Baraban, Aryeh; Kazim, Michael
2018-06-13
Diagnosing thyroid eye disease-compressive optic neuropathy (TED-CON) is challenging, particularly in cases lacking a relative afferent pupillary defect. Large case series of TED-CON patients and accessible diagnostic tools are lacking in the current literature. This study aims to create a mathematical formula that accurately predicts the presence or absence of CON based on the most salient clinical measures of optic neuropathy. A retrospective case series compares 108 patients (216 orbits) with either unilateral or bilateral TED-CON and 41 age-matched patients (82 orbits) with noncompressive TED. Utilizing clinical variables assessing optic nerve function and/or risk of compressive disease, and with the aid of generalized linear regression modeling, the authors create a mathematical formula that weighs the relative contribution of each clinical variable in the overall prediction of CON. Data from 213 orbits in 110 patients derived the formula: y = -0.69 + 2.58 × (afferent pupillary defect) - 0.31 × (summed limitation of ductions) - 0.2 × (mean deviation on Humphrey visual field testing) - 0.02 × (% color plates). This accurately predicted the presence of CON (y > 0) versus non-CON (y < 0) in 82% of cases with 83% sensitivity and 81% specificity. When there was no relative afferent pupillary defect, which was the case in 63% of CON orbits, the formula correctly predicted CON in 78% of orbits with 73% sensitivity and 83% specificity. The authors developed a mathematical formula, the Columbia TED-CON Formula (CTD Formula), that can help guide clinicians in accurately diagnosing TED-CON, particularly in the presence of bilateral disease and when no relative afferent pupillary defect is present.
Alvarez Padilla, Facundo Nicolás; Schiavoni, Emiliano Nestor; Bustos, Mario Eduardo Francisco
2018-04-20
INTRODUCCIONEl derrame pleural neoplásico (DPN) implica una enfermedad oncológica avanzada. La biopsia pleural por cirugía torácica endoscópica permite el diagnóstico en más del 90% de los casos y la instrumentación del espacio pleural complicado, mejorando los resultados de la técnica.MATERIAL Y METODOSe realizó un análisis retrospectivo de pacientes con DPN operados para la realización de una pleurodesis química con talco. Se formaron dos grupos, uno con derrame pleural neoplásico complicado (DPNC) y otro con derrame pleural neoplásico no complicado (DPNNC). En el grupo con DPNC se realizó "maniobras de liberación - expansión". Se compararon las variables entre ambos grupos para el análisis pertinente.RESULTADOSSe analizaron 28 pacientes con DPN tratados con pleurodesis química por cirugía torácica endoscópica. La edad promedio fue de 62,64 años. El compromiso pleural por patología mamaria fue la forma más frecuente (46,4%). No se hubo diferencia en cuanto a complicaciones (p= 0,31) y riesgo de defunción a los 30 días (p=1,09) con el manejo agresivo del espacio pleural. La demora en la indicación de pleurodesis se relacionó con un mayor índice de complicaciones (p=0,002) y mayor probabilidad de defunción dentro de los 30 días (p=0,008). La mayoría de pacientes se reinsertó a sus tareas diarias, con buena tolerancia a la disnea luego del procedimiento. CONCLUSIONEn los pacientes con DPNC, las "maniobras de liberación - expansión pulmonar" descriptas, aumentarían las chances de mejorar los resultados con bajo riesgo. La pleurodesis química temprana mejora la calidad de vida de los pacientes portadores de un DPN.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fullerton, Aaron M., E-mail: fuller22@msu.edu; Roth, Robert A., E-mail: rothr@msu.edu; Ganey, Patricia E., E-mail: ganey@msu.edu
Inflammation plays a major role in immune-mediated liver injury, and exposure to environmental pollutants such as 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) has been reported to alter the inflammatory response as well as affect immune cell activity. In this study, we tested the hypothesis that TCDD pretreatment exacerbates hepatotoxicity in a murine model of immune-mediated liver injury induced by concanavalin A (Con A) administration. Mice were pretreated with 30 μg/kg TCDD or vehicle control on day zero and then given either Con A or saline intravenously on day four. Mice treated with TCDD did not develop liver injury; however, TCDD pretreatment increased liver injurymore » resulting from moderate doses of Con A (4–10 mg/kg). TCDD-pretreated mice had altered plasma concentrations of inflammatory cytokines, including interferon gamma (IFNγ), and TCDD/Con A-induced hepatotoxicity was attenuated in IFNγ knockout mice. At various times after treatment, intrahepatic immune cells were isolated, and expression of cell activation markers as well as cytolytic proteins was determined. TCDD pretreatment increased the proportion of activated natural killer T (NKT) cells and the percent of cells expressing Fas ligand (FasL) after Con A administration. In addition FasL knockout mice and mice treated with CD18 antiserum were both protected from TCDD/Con A-induced hepatotoxicity, suggesting a requirement for direct cell–cell interaction between effector immune cells and parenchymal cell targets in the development of liver injury from TCDD/Con A treatment. In summary, exposure to TCDD increased NKT cell activation and exacerbated immune-mediated liver injury induced by Con A through a mechanism involving IFNγ and FasL expression. -- Highlights: ► TCDD pretreatment sensitizes mice to Con A-induced hepatotoxicity. ► TCDD pretreatment increased concentration of IFNγ in plasma after Con A. ► Con A-induced activation of NKT cells was increased by TCDD pretreatment. ► FasL-positive NKT cells increased with TCDD pretreatment versus Con A alone. ► IFNγ and FasL are critical to the development of liver injury from TCDD/Con A.« less
Ying, Zhixiong; Zhang, Hao; Su, Weipeng; Zhou, Le; Wang, Fei; Li, Yue; Zhang, Lili; Wang, Tian
2017-10-01
Background: Individuals with intrauterine growth restriction (IUGR) are prone to developing type 2 diabetes mellitus (T2DM). Dietary methionine restriction (MR) improves insulin sensitivity and glucose homeostasis in individuals with normal birth weight (NBW). Objective: This study investigated the effects of MR on plasma glucose concentration and hepatic and muscle glucose metabolism in pigs with IUGR. Methods: Thirty female NBW and 60 same-sex spontaneous IUGR piglets (Landrace × Yorkshire) were selected. After weaning (day 21), the piglets were fed diets with adequate methionine (NBW-CON and IUGR-CON) or 30% less methionine (IUGR-MR) ( n = 6). At day 180, 1 pig with a body weight near the mean of each replication was selected for biochemical analysis. Results: The IUGR-CON group showed 41.6%, 68.6%, and 67.1% higher plasma glucose concentration, hepatic phosphoenolpyruvate carboxykinase activity, and glucose-6-phosphatase activity, respectively, than the NBW-CON group ( P < 0.05). Muscle glycogen content and glycogen synthase activity were 36.9% and 38.8% lower, respectively, in the IUGR-CON than the NBW-CON group ( P < 0.05), respectively, and there was decreased hepatic and muscle protein kinase B phosphorylation in the IUGR-CON group ( P < 0.05). Compared with the IUGR-CON pigs, the IUGR-MR pigs had 28.7% lower plasma glucose concentrations ( P < 0.05), which were similar to those of the NBW-CON pigs ( P ≥ 0.05). The hepatic glycogen content and glycogen synthase activity of the IUGR-MR pigs were 62.9% and 50.8% higher than those of the IUGR-CON pigs ( P < 0.05) and 53.5% and 84.3% higher than the NBW-CON pigs ( P < 0.05), respectively. The IUGR-MR pigs' hepatic and muscle protein kinase B phosphorylation was higher than that of the IUGR-CON pigs ( P < 0.05) and similar to that of the NBW-CON pigs ( P ≥ 0.05). Conclusion: MR attenuates hyperglycemia in IUGR pigs by enhancing hepatic protein kinase B signaling and glycogen synthesis, implying a potential nutritional strategy to prevent type 2 diabetes mellitus in IUGR offspring. © 2017 American Society for Nutrition.
Vielmuth, Franziska; Schumann, Ricarda G; Spindler, Volker; Wolf, Armin; Scheler, Renate; Mayer, Wolfgang J; Henrich, Paul B; Haritoglou, Christos
2017-01-01
Objetivo: Evaluar la rigidez de la membrana limitante interna (MLI) humana y evaluar los posibles cambios de las propiedades mecánicas tras administrar una inyección intravítrea de ocriplasmina para tratar la tracción vitreomacular. Métodos: Este estudio se compone de una serie de casos intervencionales y comparativos de 12 muestras de MLI extraídas mediante cirugía y obtenidas de forma consecutiva de 9 ojos de 9 pacientes después de someterse sin éxito a vitreólisis farmacológica con ocriplasmina. Durante el mismo periodo de tiempo, 16 muestras de otros 13 ojos sin tratamiento con ocriplasmina se obtuvieron mediante vitrectomía y sirvieron como controles. Todos los pacientes presentaron agujeros maculares o tracción vitreomacular y se sometieron a vitrectomía con disección de la MLI tanto con tinción con azul brillante (AB) como sin ella. Todas las muestras se analizaron con un microscopio de fuerza atómica con imágenes de las regiones de 25 × 25 μm. En todas las muestras, se analizaron tanto la parte de la retina como la del vítreo de la MLI. Resultados: La microscopia de fuerza atómica no reveló diferencias significativas en cuanto a elasticidad de las muestras de MLI extraídas de ojos con o sin tratamiento con ocriplasmina. Las áreas onduladas de la parte de la retina presentaron una mayor rigidez que la parte del vítreo de la MLI. La cartografía topográfica tanto de la parte del vítreo como de la retina de la MLI no mostró ninguna alteración aparente de la morfología en ojos tratados con ocriplasmina en comparación con los ojos no tratados. La tinción con azul brillante conllevó un aumento de la rigidez tisular. Conclusiones: Las inyecciones intravítreas de ocriplasmina no varían las propiedades biomecánicas de la MLI humana. No existen pruebas de un posible efecto enzimático que interfiera con la rigidez de esta membrana basal. © 2017 S. Karger AG, Basel.
Code of Federal Regulations, 2010 CFR
2010-10-01
... REGULATION SYSTEM Career Development, Contracting Authority, and Responsibilities 301.608 Training... new DPA. b CON 237, CON 100, and CON 110 are available at the DAU Web site at http://www.dau.mil/registrar/enroll.asp. CON 100 is also offered through HHS University (see Web site at: http://learning.hhs...
Nakano, Eri; Hata, Masayuki; Oishi, Akio; Miyamoto, Kazuaki; Uji, Akihito; Fujimoto, Masahiro; Miyata, Manabu; Yoshimura, Nagahisa
2016-08-01
The purpose was to investigate an objective and quantitative method to estimate the redness of the optic disc neuroretinal rim, and to determine the usefulness of this method to differentiate compressive optic neuropathy (CON) from glaucomatous optic neuropathy (GON). In our study there were 126 eyes: 40 with CON, 40 with normal tension glaucoma (NTG), and 46 normal eyes (NOR). Digital color fundus photographs were assessed for the redness of disc rim color using ImageJ software. We separately measured the intensity of red, green, and blue pixels from RGB images. Three disc color indices (DCIs), which indicate the redness intensity, were calculated through existing formulas. All three DCIs of CON were significantly smaller than those of NOR (P < 0.001). In addition, when compared with NTG, DCIs were also significantly smaller in CON (P < 0.05). A comparison of mild CON and mild NTG (mean deviation (MD) > -6 dB), in which the extent of retinal nerve fiber layer thinning is comparable, the DCIs of mild CON were significantly smaller than those of mild NTG (P < 0.05). In contrast, DCIs did not differ between moderate-to-severe stages of CON and NTG (MD ≤ -6 dB), though the retinal nerve fibers of CON were more severely damaged than those of NTG. To differentiate between mild CON and mild NTG, all AUROCs for the three DCIs were above 0.700. A quantitative and objective assessment of optic disc color was useful in differentiating early-stage CON from GON and NOR.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Coniothyrium minitans strain CON/M/91... PESTICIDE CHEMICAL RESIDUES IN FOOD Exemptions From Tolerances § 180.1213 Coniothyrium minitans strain CON/M... tolerance is established for residues of the microbial pesticide Coniothyrium minitans strain CON/M/91-08...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Coniothyrium minitans strain CON/M/91... PESTICIDE CHEMICAL RESIDUES IN FOOD Exemptions From Tolerances § 180.1213 Coniothyrium minitans strain CON/M... tolerance is established for residues of the microbial pesticide Coniothyrium minitans strain CON/M/91-08...
Hilbrands, A M; Johnston, L J; McClelland, K M; Cox, R B; Baidoo, S K; Souza, L W O; Shurson, G C
2013-01-01
Two experiments were conducted to evaluate the effects of feeding continuously a diet containing 40% dried distillers grains with solubles (DDGS) or intermittently diets containing 20 or 40% DDGS on growth performance and carcass quality of pigs. Responses of the pigs to abrupt introduction and removal of dietary DDGS with differing concentrations of standardized ileal digestible (SID) AA were also evaluated. In Exp. 1, crossbred pigs (n=216; initial BW=51.3±3.1 kg) were assigned randomly to 1 of 4 treatments, which included a corn-soybean meal control (CON), a 20% DDGS diet (D20), a switch between D20 and CON (D20-CON), and a switch between a 40% DDGS diet and CON (D40-CON) with 6 pens per treatment. Pigs abruptly introduced and removed from a 20% DDGS diet (D20-CON) exhibited no differences in growth performance or carcass quality compared with CON pigs. However, intermittently feeding a 40% DDGS diet (D40-CON) resulted in lighter HCW (P<0.05) compared with all other treatments. In Exp. 2, crossbred pigs (n=324; initial BW=33.2±3.0 kg) were assigned randomly to 1 of 6 treatments, including a corn-soybean meal control (CON), a 40% low SID AA DDGS diet (LD), a 40% high SID AA DDGS diet (HD), LD and CON diets alternated (LD-CON), HD and CON diets alternated (HD-CON), or HD and LD diets alternated (HD-LD) with 6 pens per treatment. Final BW and ADG were less (P<0.05) for LD and HD-LD pigs compared with CON pigs, but HD pigs tended to have reduced (P<0.10) final BW and ADG. Loin muscle area was smaller for LD and HD-LD pigs compared with CON pigs (P<0.05). Percentage carcass lean was not affected by dietary treatment. Backfat of DDGS-fed pigs was more unsaturated than CON pigs, but AA digestibility of DDGS did not affect this response. Digestibility of AA in DDGS can influence pig performance and carcass quality when fed at high concentrations (40% or more). The use of a high SID AA DDGS source may diminish some of the negative responses observed for growth performance and carcass characteristics when feeding high concentrations of DDGS if accurate values of SID AA are used in diet formulation. Periodic inclusion and removal of 40% DDGS from diets did not adversely affect growth performance or carcass quality regardless of the SID AA digestibility of the DDGS used. These results indicate that it is possible to abruptly incorporate and remove DDGS from grower-finisher swine diets without meaningful detrimental effects on growth performance or carcass quality.
Pros and Cons of International Weapons Procurement Collaboration.
1995-01-01
ad- vanced U.S. industry. Greater risk of cost growth and schedule slippage. Pro: U.S. and partners share common equip- ment. Con : U.S. require...Mark A., 1947- Pros and cons of international weapons procurement collaboration / Mark Lorell, Julia Lowell, p. cm "Prepared for the Office...one/ Cons of International Weapons Procurement Collaboration Mark Lorell Julia Lowell National Defense Research Institute Prepared for the
Cao, Haihui; Nazarian, Ara; Ackerman, Jerome L; Snyder, Brian D; Rosenberg, Andrew E; Nazarian, Rosalynn M; Hrovat, Mirko I; Dai, Guangping; Mintzopoulos, Dionyssios; Wu, Yaotang
2010-06-01
In this study, bone mineral density (BMD) of normal (CON), ovariectomized (OVX), and partially nephrectomized (NFR) rats was measured by (31)P NMR spectroscopy; bone matrix density was measured by (1)H water- and fat-suppressed projection imaging (WASPI); and the extent of bone mineralization (EBM) was obtained by the ratio of BMD/bone matrix density. The capability of these MR methods to distinguish the bone composition of the CON, OVX, and NFR groups was evaluated against chemical analysis (gravimetry). For cortical bone specimens, BMD of the CON and OVX groups was not significantly different; BMD of the NFR group was 22.1% (by (31)P NMR) and 17.5% (by gravimetry) lower than CON. For trabecular bone specimens, BMD of the OVX group was 40.5% (by (31)P NMR) and 24.6% (by gravimetry) lower than CON; BMD of the NFR group was 26.8% (by (31)P NMR) and 21.5% (by gravimetry) lower than CON. No significant change of cortical bone matrix density between CON and OVX was observed by WASPI or gravimetry; NFR cortical bone matrix density was 10.3% (by WASPI) and 13.9% (by gravimetry) lower than CON. OVX trabecular bone matrix density was 38.0% (by WASPI) and 30.8% (by gravimetry) lower than CON, while no significant change in NFR trabecular bone matrix density was observed by either method. The EBMs of OVX cortical and trabecular specimens were slightly higher than CON but not significantly different from CON. Importantly, EBMs of NFR cortical and trabecular specimens were 12.4% and 26.3% lower than CON by (31)P NMR/WASPI, respectively, and 4.0% and 11.9% lower by gravimetry. Histopathology showed evidence of osteoporosis in the OVX group and severe secondary hyperparathyroidism (renal osteodystrophy) in the NFR group. These results demonstrate that the combined (31)P NMR/WASPI method is capable of discerning the difference in EBM between animals with osteoporosis and those with impaired bone mineralization. Copyright 2010 Elsevier Inc. All rights reserved.
Boo, Nem Yun; Suhaida, Abdul Rahman; Rohana, Jaafar
2015-01-01
INTRODUCTION This case-control study aimed to determine whether catheter use was significantly associated with coagulase-negative staphylococci (CoNS) colonisation and/or sepsis in neonates. METHODS Weekly swabs of the nose, umbilicus, rectum, wounds, eye discharge and intravenous catheter tips (after removal) of infants admitted to the neonatal intensive care unit of Universiti Kebangsaan Malaysia Medical Centre, Malaysia, were cultured. CoNS sepsis was diagnosed if pure growth of CoNS was cultured from the peripheral blood specimen of symptomatic infants. For each infant with CoNS colonisation or sepsis, a control infant was retrospectively and randomly selected from unaffected infants in the ward. Multivariate analyses were performed to determine whether catheter use was a significant risk factor. RESULTS CoNS colonisation was detected in 113 (8.7%) infants. CoNS sepsis was found in 12 (10.6%) infants with CoNS colonisation and 7 (0.6%) infants without CoNS colonisation. Multivariate analysis showed that the following were significantly associated with CoNS colonisation: conjunctivitis (adjusted odds ratio [OR] 8.2, 95% confidence interval [CI] 1.9–34.8, p = 0.005); central venous catheters (adjusted OR 5.8, 95% CI 1.9–17.8, p = 0.002); and nasopharyngeal and/or oral suctioning more than twice in the 48 hours before positive culture (adjusted OR 7.3, 95% CI 3.3–16.2, p < 0.001). Exposure to frequent nasopharyngeal and/or oral suctioning (adjusted OR 20.8, 95% CI 3.5–125.3, p = 0.001) was the only significant factor associated with CoNS sepsis. CONCLUSION Infants requiring more than two nasopharyngeal and/or oral suctions in the previous 48 hours were found to have a higher risk of developing CoNS colonisation and sepsis. PMID:25532513
Kuo, Chia-Hua; Hwang, Hyonson; Lee, Man-Cheong; Castle, Arthur L; Ivy, John L
2004-02-01
The purpose of this study was to investigate the role of insulin on skeletal muscle GLUT-4 protein expression and glycogen storage after postexercise carbohydrate supplementation. Male Sprague-Dawley rats were randomly assigned to one of six treatment groups: sedentary control (Con), Con with streptozocin (Stz/C), immediately postexercise (Ex0), Ex0 with Stz (Stz/Ex0), 5-h postexercise (Ex5), and Ex5 with Stz (Stz/Ex5). Rats were exercised by swimming (2 bouts of 3 h) and carbohydrate supplemented immediately after each exercise session by glucose intubation (1 ml of a 50% wt/vol). Stz was administered 72-h before exercise, which resulted in hyperglycemia and elimination of the insulin response to the carbohydrate supplement. GLUT-4 protein of Ex0 rats was 30% above Con in fast-twitch (FT) red and 21% above Con in FT white muscle. In Ex5, GLUT-4 protein was 52% above Con in FT red and 47% above Con in FT white muscle. Muscle glycogen in FT red and white muscle was also increased above Con in Ex5 rats. Neither GLUT-4 protein nor muscle glycogen was increased above Con in Stz/Ex0 or Stz/Ex5 rats. GLUT-4 mRNA in FT red muscle of Ex0 rats was 61% above Con but only 33% above Con in Ex5 rats. GLUT-4 mRNA in FT red muscle of Stz/C and Stz/Ex0 rats was similar but significantly elevated in Ex5/Stz rats. These results suggest that insulin is essential for the increase in GLUT-4 protein expression following postexercise carbohydrate supplementation.
A Randomized Phase 2 Study of Long-Acting TransCon GH vs Daily GH in Childhood GH Deficiency.
Chatelain, Pierre; Malievskiy, Oleg; Radziuk, Klaudziya; Senatorova, Ganna; Abdou, Magdy O; Vlachopapadopoulou, Elpis; Skorodok, Yulia; Peterkova, Valentina; Leff, Jonathan A; Beckert, Michael
2017-05-01
TransCon Growth Hormone (GH) (Ascendis Pharma) is a long-acting recombinant sustained-release human GH prodrug in development for children with GH deficiency (GHD). To compare the pharmacokinetics, pharmacodynamics, safety, and efficacy of weekly TransCon GH to that of daily GH in prepubertal children with GHD. Randomized, open-label, active-controlled study of three doses of weekly TransCon GH versus daily Genotropin (Pfizer). Thirty-eight centers in 14 European countries and Egypt. Prepubertal male and female treatment-naïve children with GHD (n = 53). Subjects received one of three TransCon GH doses (0.14, 0.21, or 0.30 mg GH/kg/wk) or Genotropin 0.03 mg GH/kg/d for 26 weeks. GH and insulinlike growth factor-1 (IGF-1) levels, growth, adverse events, and immunogenicity. Both GH maximum concentration and area under the curve were similar following TransCon GH or Genotropin administration at comparable doses. A dose response was observed, with IGF-1 standard deviation scores increasing into the normal range for all three TransCon GH doses. Annualized mean height velocity for the three TransCon GH doses ranged from 11.9 cm to 13.9 cm, which was not statistically different from 11.6 cm for Genotropin. Adverse events were mild to moderate, and most were unrelated to the study drug. Injection site tolerance was good. One TransCon GH subject developed a low-titer, nonneutralizing antibody response to GH. The results suggest that long-acting TransCon GH is comparable to daily Genotropin for GH (pharmacokinetics) and IGF-1 (pharmacodynamics) levels, safety, and efficacy and support advancement into phase 3 development. Copyright © 2017 Endocrine Society
Immunocontraception for Managing Feral Cattle in Hong Kong
Massei, Giovanna; Koon, Ka-Kei; Benton, Steven; Brown, Richard; Gomm, Matt; Orahood, Darcy S.; Pietravalle, Stéphane; Eckery, Douglas C.
2015-01-01
Conflicts between human interests and feral cattle in Hong Kong derive from growing numbers of free-roaming cattle. Public antipathy towards lethal population control led the local authorities to consider fertility control to reduce cattle numbers. This study assessed the potential side effects of the immunocontraceptive GonaCon on individual female cattle and established the effectiveness of GonaCon to induce infertility. We evaluated GonaCon in 34 captive cattle assigned to four groups: Control administered a sham solution; Webbed (surgically sterilized through removal of the oviducts), administered one dose of GonaCon; Webbed, administered one dose of GonaCon and a booster dose three months later, and Treated, administered one dose of GonaCon. The side effects of GonaCon were assessed by monitoring injection site, body weight, body condition, size of lymph nodes, body temperature, and feeding behaviour 1 week and 1, 3, 6, 9 and 12 months after vaccination and by haematological and biochemical variables at vaccination and three months post-vaccination. The effectiveness of GonaCon to cause infertility was monitored by quantifying anti-GnRH antibody titres and by using kits to detect cycling and pregnancy. GonaCon-treated cattle showed no injection site reaction, limping, or abnormal behaviour. No differences were observed in all physiological and welfare indicators between control and vaccinated cattle. All control cattle and 4 of the 12 cattle in the Treated group became pregnant. Cattle administered a booster dose had higher anti-GnRH antibody titres than cattle that received one dose. We concluded that GonaCon does not compromise the animals’ welfare and is effective in reducing fertility in cattle. A booster dose is likely to increase the duration of infertility. Further studies are required to assess the feasibility and costs of immunocontraception for controlling free-roaming cattle populations. PMID:25856283
Immunocontraception for managing feral cattle in Hong Kong.
Massei, Giovanna; Koon, Ka-Kei; Benton, Steven; Brown, Richard; Gomm, Matt; Orahood, Darcy S; Pietravalle, Stéphane; Eckery, Douglas C
2015-01-01
Conflicts between human interests and feral cattle in Hong Kong derive from growing numbers of free-roaming cattle. Public antipathy towards lethal population control led the local authorities to consider fertility control to reduce cattle numbers. This study assessed the potential side effects of the immunocontraceptive GonaCon on individual female cattle and established the effectiveness of GonaCon to induce infertility. We evaluated GonaCon in 34 captive cattle assigned to four groups: Control administered a sham solution; Webbed (surgically sterilized through removal of the oviducts), administered one dose of GonaCon; Webbed, administered one dose of GonaCon and a booster dose three months later, and Treated, administered one dose of GonaCon. The side effects of GonaCon were assessed by monitoring injection site, body weight, body condition, size of lymph nodes, body temperature, and feeding behaviour 1 week and 1, 3, 6, 9 and 12 months after vaccination and by haematological and biochemical variables at vaccination and three months post-vaccination. The effectiveness of GonaCon to cause infertility was monitored by quantifying anti-GnRH antibody titres and by using kits to detect cycling and pregnancy. GonaCon-treated cattle showed no injection site reaction, limping, or abnormal behaviour. No differences were observed in all physiological and welfare indicators between control and vaccinated cattle. All control cattle and 4 of the 12 cattle in the Treated group became pregnant. Cattle administered a booster dose had higher anti-GnRH antibody titres than cattle that received one dose. We concluded that GonaCon does not compromise the animals' welfare and is effective in reducing fertility in cattle. A booster dose is likely to increase the duration of infertility. Further studies are required to assess the feasibility and costs of immunocontraception for controlling free-roaming cattle populations.
Mahgoub, Mohamed M; Macky, Tamer A
2017-07-11
Objetivo: El objetivo de este estudio fue comparar el efecto de la panfotocoagulación (PFC) en el edema macular diabético (EMD) en pacientes con retinopatía diabética proliferativa (RDP) con el fotocoagulador Pascal® (FP) vs. un fotocoagulador con láser de argón convencional (FLAC). Métodos: Se aleatorizó el uso de FP o FLAC en ochenta ojos con RDP y EMD con afectación central de la mácula. Ambos grupos tuvieron una evaluación de base de mejor agudeza visual corregida y fueron examinados con tomografía de coherencia óptica y angiografía con fluoresceína. Resultados: El número medio de disparos de láser en los grupos de FP y FLAC fue 1.726,10 y 752,00 en la sesión 1 y 1.589,00 y 830,00 (p < 0,001) en la sesión 2, respectivamente. El grosor foveal central (GFC) medio antes de comenzar el estudio fue 306 ± 100 y 314 ± 98 en los grupos de FP y FLAC, respectivamente. A las 8 semanas, el GFC medio fue 332 ± 116 y 347 ± 111 en los grupos de FP y FLAC, respectivamente (p > 0,05). La MAVC media fue similar durante el periodo de estudio y no hubo ninguna diferencia significativa entre los grupos (p > 0,05). Conclusiones: El FP y el FLAC mostraron efectos similares en el EMD en ojos con RDP y fueron igualmente seguros sin un aumento significativo del GFC. © 2017 S. Karger AG, Basel.
Investigation of the γ-decay behavior of 52Cr with the γ 3 setup at HIγS
NASA Astrophysics Data System (ADS)
Wilhelmy, J.; Erbacher, P.; Gayer, U.; Isaak, J.; Löher, B.; Müscher, M.; Pickstone, S. G.; Pietralla, N.; Ries, P.; Romig, C.; Savran, D.; Spieker, M.; Tornow, W.; Werner, V.; Zilges, A.; Zweidinger, M.
2018-02-01
The γ-ray strength function is an important input parameter for the calculation of nucleosynthesis processes. To study the dipole response in more detail, the γ-decay behavior of the fp shell nucleus 52Cr was investigated with the high-efficiency γ 3 setup at the High Intensity γ-ray Source facility at TUNL in Durham, USA. The highly intense quasi mono-energetic γ-ray beam allows for excitations selective in multipolarity (J=1 and J=2) and energy. The γ 3 setup is a multi-detector array consisting of HPGe and LaBr3 detectors with high efficiency and enables the measurement of γ-γ coincidences. Experimental results of 52Cr will be presented and discussed in this contribution.
High Intensity Focused Ultrasound Ablation of Pancreatic Neuroendocrine Tumours: Report of Two Cases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orgera, Gianluigi, E-mail: gianluigi.orgera@ieo.it; Krokidis, Miltiadis; Monfardini, Lorenzo
2011-04-15
We describe the use of ultrasound-guided high-intensity focused ultrasound (HIFU) for ablation of two pancreatic neuroendocrine tumours (NETs; insulinomas) in two inoperable young female patients. Both suffered from episodes of severe nightly hypoglycemia that was not efficiently controlled by medical treatment. After HIFU ablation, local disease control and symptom relief were achieved without postinterventional complications. The patients remained free of symptoms during 9-month follow-up. The lesions appeared to be decreased in volume, and there was decreased enhancing pattern in the multidetector computed tomography control (MDCT). HIFU is likely to be a valid alternative for symptoms control in patients with pancreaticmore » NETs. However, currently the procedure should be reserved for inoperable patients for whom symptoms cannot be controlled by medical therapy.« less
A system definition study for the Advanced Meteorological Temperature Sounder (AMTS)
NASA Technical Reports Server (NTRS)
1977-01-01
The functional requirements of Exhibit A (11) were used as the baseline for the conceptual design of a fixed grating out of plane multidetector spectrometer for the Space Shuttle application. Because the grating instrument would be large and the 28 element detector array would be difficult to cool radiatively from a free flying spacecraft and because increasing the spectral resolution of the grating instrument would be difficult in an instrument of reasonable size, a parallel study of a Nichelson interferometer spectrometer was undertaken. This type of instrument offers compact size, fewer detectors to cool, and the possibility of increased spectral resolution. The design and performance parameters of both the grating and interferometer approaches are described. The tradeoffs involved in comparing the two systems for sounding applications are discussed.
Bilateral subclavian origin of the bronchial arteries combined with absence of other origins.
Jie, Bing; Sun, Xi-Wen; Yu, Dong; Jiang, Sen
2014-08-01
There are numerous anatomical variations of the sites of origin of the bronchial arteries (BAs). A subclavian origin of a BA involves an aberrant artery that originates from the subclavian artery (SCA) or its branches. However, the aberrant artery usually originates directly from the SCA, and an SCA-origin BA arising from the branches of the SCA is rare. We herein present an extremely rare case of a right BA arising from the ipsilateral costocervical trunk, and a left BA arising from the ipsilateral thyrocervical trunk, in the absence of other origins of the BA. This anatomical variation was detected during pretherapeutic evaluation by multidetector-row computed tomography and confirmed by selective angiography. Recognition of these anatomic variations is important to surgical, diagnostic, and interventional radiologic procedures in the thorax.
Usui, Akihito; Kawasumi, Yusuke; Hosokai, Yoshiyuki; Kozakai, Masataka; Saito, Haruo; Funayama, Masato
2016-01-01
Gunshot injury has always been an important field of investigation in postmortem forensic radiology. The localization and retrieval of the bullet and of potentially important fragments are vital to these cases. Using postmortem multidetector-row computed tomography (MDCT) prior to forensic autopsy, we sought to illustrate the importance of this modality in the noninvasive characterization of gunshot wounds. We obtained and analyzed MDCT images in three cases of gunshot wounds (accidental close-range shotgun shooting, suicidal contact gunshot to the head and accidental long-range buckshot shooting). We discuss the value of postmortem MDCT findings in gunshot wound cases by comparing with forensic autopsy findings in Japan, a developing country with miserably low autopsy rate. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Test of GET Electronics for the CHIMERA and FARCOS multi-detectors
NASA Astrophysics Data System (ADS)
De Luca, S.; Acosta, L.; Auditore, L.; Boiano, C.; Cardella, G.; Castoldi, A.; D'Andrea, M.; De Filippo, E.; Dell'Aquila, D.; Fichera, F.; Gnoffo, B.; Guazzoni, C.; Lanzalone, G.; Lombardo, I.; Martorana, N. S.; Minniti, T.; Norella, S.; Pagano, A.; Pagano, E. V.; Papa, M.; Pirrone, S.; Politi, G.; Quattrocchi, L.; Rizzo, F.; Russotto, P.; Saccà, G.; Trifirò, A.; Trimarchi, M.; Verde, G.; Vigilante, M.
2017-11-01
In this paper we present the results of the tests on the new digital electronics GET (General Electronics for Tpc), which will be used for the readout of the CsI(Tl) detectors of CHIMERA (Charged Heavy Ion Mass and Energy Resolving Array) and for the new correlator FARCOS (Femtoscope ARray for COrrelations and Spectroscopy). The new electronics allows us to digitize the full waveform of the signals produced by the detector. Among its features it is worth noticing the compactness and low power consumption (5W for 256 channels). Tests have been performed with pulsers, radioactive sources and ion beams. With such electronics very good results in energy resolution and isotope separation of the detected fragments were obtained, by using both hardware and software filters.
PDCO: Polarizational-directional correlation from oriented nuclei
NASA Astrophysics Data System (ADS)
Droste, Ch.; Rohoziński, S. G.; Starosta, K.; Morek, T.; Srebrny, J.; Magierski, P.
1996-02-01
A general formula is given for correlation between two polarized gamma rays ( γ1 and γ2) emitted in a cascade from an oriented (for example, due to a heavy ion reaction) nucleus. It allows us or one to calculate the angular correlation between: (a) Linear polarizations of γ1 and γ2. (b) Polarization of γ1 and direction of γ2 or vice versa. (c) Directions of γ1 and γ2 (DCO). The formula, discussed in detail for the case (b), can be used in the analysis of data coming from the modern multidetector gamma ray spectrometers that contain new generation detectors (e.g. CLOVER) sensitive to the polarization. The analysis of polarization together with DCO ratio can lead to a unique spin/parity assignment and a mixing ratio determination.
NASA Astrophysics Data System (ADS)
Kang, D.; Apel, W. D.; Arteaga-Velazquez, J. C.; Bekk, K.; Bertaina, M.; Blümer, J.; Bozdog, H.; Brancus, I. M.; Cantoni, E.; Chiavassa, A.; Cossavella, F.; Daumiller, K.; de Souza, V.; Di Pierro, F.; Doll, P.; Engel, R.; Engler, J.; Finger, M.; Fuchs, B.; Fuhrmann, D.; Gils, H. J.; Glasstetter, R.; Grupen, C.; Haungs, A.; Heck, D.; Hörandel, J. R.; Huber, D.; Huege, T.; Kampert, K.-H.; Klages, H. O.; Link, K.; Łuczak, P.; Ludwig, M.; Mathes, H. J.; Mayer, H. J.; Melissas, M.; Milke, J.; Morello, C.; Oehlschläger, J.; Ostapchenko, S.; Palmieri, N.; Petcu, M.; Pierog, T.; Rebel, H.; Roth, M.; Schieler, H.; Schoo, S.; Schroder, F.; Sima, O.; Toma, G.; Trinchero, G. C.; Ulrich, H.; Weindl, A.; Wochele, J.; Wommer, M.; Zabierowski, J.
2013-02-01
KASCADE-Grande is a large detector array for observations of the energy spectrum as well as the chemical composition of cosmic ray air showers up to primary energies of 1 EeV. The multi-detector arrangement allows to measure the electromagnetic and muonic components for individual air showers. In this analysis, the reconstruction of the all-particle energy spectrum is based on the size spectra of the charged particle component. The energy is calibrated by using Monte Carlo simulations performed with CORSIKA and high-energy interaction models QGSJet, EPOS and SIBYLL. In all cases FLUKA has been used as low-energy interaction model. In this contribution the resulting spectra by means of different hadronic interaction models will be compared and discussed.
Broad ligament hernia successfully repaired by single-incision laparoscopy: A case report.
Takeyama, Hiroshi; Kogita, Yuya; Nishigaki, Takahiko; Yamashita, Masafumi; Aikawa, Eriko; Hoshi, Minako; Taniguchi, Hirokazu; Maruyama, Yasuki; Nakajima, Kazuhiro; Yamamoto, Yoshimitsu; Adachi, Kazushige; Yamamoto, Hitoshi; Ikeda, Kimimasa; Kurokawa, Eiji
2017-11-08
A 52-year-old woman with a history of two parturitions presented with lower abdominal pain. Multi-detector CT of the abdomen showed discontinuity of the sigmoid colon near the broad ligament on the left side. We assigned a provisional diagnosis of an internal hernia progressing through a defect in the broad ligament. SILS revealed a total broad ligament defect on the left side but no signs of ischemic, necrotic bowel. We successfully repaired the broad ligament defect with suturing. At the 2-month follow-up, the patient remained well with no signs of recurrence. This case appears to be the first report of a broad ligament hernia successfully diagnosed and repaired by SILS. © 2017 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
High-throughput SANS experiment on two-detector system of YuMO spectrometer
NASA Astrophysics Data System (ADS)
Kuklin, A. I.; Ivankov, A. I.; Soloviov, D. V.; Rogachev, A. V.; Kovalev, Yu S.; Soloviev, A. G.; Islamov, A. Kh; Balasoiu, M.; Vlasov, A. V.; Kutuzov, S. A.; Sirotin, A. P.; Kirilov, A. S.; Skoi, V. V.; Rulev, M. I.; Gordeliy, V. I.
2018-03-01
Using a multidetector system on the YuMO spectrometer allows shortening the time of measurements. The quantitative comparison of the measurement time using one and two-detector mode is done. The time range for experiments was from several minutes up to 12 hours. It was shown that two-detector system shortens more than twice the time of the measurement. While making a structural investigation using advanced software the two-detector system allows to treat the data at a qualitatively new level. An example illustrating the features of the channels choice and measurement time on the spectrometer was shown. The results of this paper could be used when planning the experiments on the YuMO spectrometer, for modernization of the installation and for equipment using time-of-flight method.
Dose reduction in paediatric MDCT: general principles.
Paterson, A; Frush, D P
2007-06-01
The number of multi-detector array computed tomography (MDCT) examinations performed per annum continues to increase in both the adult and paediatric populations. Estimates from 2003 suggested that CT contributed 17% of a radiology department's workload, yet was responsible for up to 75% of the collective population dose from medical radiation. The effective doses for some CT examinations today overlap with those argued to have an increased risk of cancer. This is especially pertinent for paediatric CT, as children are more radiosensitive than adults (and girls more radiosensitive than boys). In addition, children have a longer life ahead of them, in which radiation induced cancers may become manifest. Radiologists must be aware of these facts and practise the ALARA (as low as is reasonably achievable) principle, when it comes to deciding CT protocols and parameters.
Trabecular bone class mapping across resolutions: translating methods from HR-pQCT to clinical CT
NASA Astrophysics Data System (ADS)
Valentinitsch, Alexander; Fischer, Lukas; Patsch, Janina M.; Bauer, Jan; Kainberger, Franz; Langs, Georg; DiFranco, Matthew
2015-03-01
Quantitative assessment of 3D bone microarchitecture in high-resolution peripheral quantitative computed tomography (HR-pQCT) has shown promise in fracture risk assessment and biomechanics, but is limited to the distal radius and tibia. Trabecular microarchitecture classes (TMACs), based on voxel-wise clustering texture and structure tensor features in HRpQCT, is extended in this paper to quantify trabecular bone classes in clinical multi-detector CT (MDCT) images. Our comparison of TMACs in 12 cadaver radii imaged using both HRpQCT and MDCT yields a mean Dice score of up to 0.717+/-0.40 and visually concordant bone quality maps. Further work to develop clinically viable bone quantitative imaging using HR-pQCT validation could have a significant impact on overall bone health assessment.
2001-06-01
34 Table 4. Pros and Cons of Alternate Solutions ................................................................. 43 viii Abstract...the best structure for the Air Force goes beyond the scope of this paper. The table below summarizes the pros and cons of the three alternate...solutions presented. Table 4. Pros and Cons of Alternate Solutions Solution Pros Cons No CRU Centralized management and training, few MOG limitations
Muscle fiber characteristics and performance correlates of male Olympic-style weightlifters.
Fry, Andrew C; Schilling, Brian K; Staron, Robert S; Hagerman, Fredrick C; Hikida, Robert S; Thrush, John T
2003-11-01
Biopsies fro the vastus lateralis muscle of male weightlifters (WL; n=6; X +/- SE, age=27.0 +/- 2.1 years), and non-weight-trained men (CON; n=7; age=27.0 +/- 2.0 years) were compared for fiber types, myosin heavy chain (MHC) and titin content, and fiber type-specific capillary density. Differences (p<0.05) were observed for percent fiber types IIC (WL=0.4 +/- 0.2, CON=2.4 +/- 0.8); IIA (WL=50.5 +/- 3.2, CON=26.9 +/- 3.7); and IIB (WL=1.7 +/- 1.4, CON=21.0 +/- 5.3), as well as percent MHC IIa (WL=65.3 +/- 2.4, CON=52.1 +/- 4.2) and percent MHC IIB (WL=0.9 +/- 0.9; CON=18.2 +/- 6.1). All WL exhibited only the titin-1 isoform. Capillary density (caps.mm(-2)) for all fiber types combined was greater for the CON subjects (WL=192.7 +/- 17.3; CON=262.9 +/- 26.3), due primarily to a greater capillary density in the IIA fibers. Weightlifting performances and vertical jump power were correlated with type II fiber characteristics. These results suggest that successful weightlifting performance is not dependent on IIB fibers, and that weightlifters exhibit large percentages of type IIA muscle fibers and MHC IIa isoform content.
ComSciCon: The Communicating Science Workshop for Graduate Students
NASA Astrophysics Data System (ADS)
Sanders, Nathan; Drout, Maria; Kohler, Susanna; Cook, Ben; ComSciCon Leadership Team
2018-01-01
ComSciCon (comscicon.com) is a national workshop series organized by graduate students, for graduate students, focused on leadership and training in science communication. Our goal is to empower young scientists to become leaders in their field, propagating appreciation and understanding of research results to broad and diverse audiences. ComSciCon attendees meet and interact with professional communicators, build lasting networks with graduate students in all fields of science and engineering from around the country, and write and publish original works. ComSciCon consists of both a flagship national conference series run annually for future leaders in science communication, and a series of regional and specialized workshops organized by ComSciCon alumni nationwide. We routinely receive over 1000 applications for 50 spots in our national workshop. Since its founding in 2012, over 300 STEM graduate students have participated in the national workshop, and 23 local spin-off workshops have been organized in 10 different locations throughout the country. This year, ComSciCon is working to grow as a self-sustaining organization by launching as an independent 501(c)(3) non-profit. In this poster we will discuss the ComSciCon program and methods, our results to date, potential future collaborations between ComSciCon and AAS, and how you can become involved.
ConSpeciFix: Classifying prokaryotic species based on gene flow.
Bobay, Louis-Marie; Ellis, Brian Shin-Hua; Ochman, Howard
2018-05-16
Classification of prokaryotic species is usually based on sequence similarity thresholds, which are easy to apply but lack a biologically-relevant foundation. Here, we present ConSpeciFix, a program that classifies prokaryotes into species using criteria set forth by the Biological Species Concept, thereby unifying species definition in all domains of life. ConSpeciFix's webserver is freely available at www.conspecifix.com. The local version of the program can be freely downloaded from https://github.com/Bobay-Ochman/ConSpeciFix. ConSpeciFix is written in Python 2.7 and requires the following dependencies: Usearch, MCL, MAFFT and RAxML. ljbobay@uncg.edu.
Horiuchi, Satoshi; Tsuda, Akira; Kobayashi, Hisanori; Fallon, Elizabeth A; Sakano, Yuji
2017-07-01
This study examined self-efficacy (confidence to exercise), pros (exercise's advantages), and cons (exercise's disadvantages) as variables associated across the transtheoretical model's six stages of change in 403 Japanese college students. A series of logistic regression analyses were conducted. Results showed that higher pros and lower cons were associated with being in contemplation compared to precontemplation. Lower cons were associated with being in preparation compared to contemplation. Higher self-efficacy was associated with being in action compared to preparation as well as being in maintenance compared to action. Lower cons were associated with being in termination compared to maintenance.
Mejoras en la exactitud del reloj de ángulo horario del telescopio de 2,15 mts de CASLEO
NASA Astrophysics Data System (ADS)
Aballay, J. L.; Pereyra, P. F.; Marún, A. H.
Para aumentar la exactitud en el control del ángulo horario del telescopio, se está implementando el uso de un reloj con una precisión de 1/100 seg. En conjunto con el encoder que otorga la posición con un acierto de 0,012 seg. de arco, se podrá implementar otro dígito en el reloj de ángulo horario con la posibilidad de ver las décimas. Esto, sumado a la precisión ya lograda en declinación, permitirá realizar offsets con mayor exactitud.
Do hospital chief executive officers extract rents from Certificate of Need laws?
Eichmann, Traci L; Santerre, Rexford E
2011-01-01
Prior research suggests that Certificate of Need (CON) laws reduce competition in the hospital services industry. As a result, this study empirically investigates if not-for-profit hospital chief executive officers (CEOs) are able to extract rents from CON laws in the form of higher compensation. A sample of 256 not-for-profit hospital CEOs in states with and without CON laws and data for 2007 are used in the empirical analysis. The study considers the endogenous nature of a CON law and allows such a law to indirectly affect CEO compensation through its impact on the number of hospitals and beds. The multiple regression results indicate that special and public interests both motivate the decision of a state to maintain a CON law. CON laws are shown to reduce the number of beds at the typical hospital by 12 percent, on average, and the number of hospitals per 100,000 persons by 48 percent. These reductions ultimately lead urban hospital CEOs in states with CON laws to extract economic rents of $91,000 annually.
Kim, Ho Myeong; Cho, Eun Jin; Bae, Hyeun-Jong
2016-08-01
Jack bean (JB, Canavalia ensiformis) is the source of bio-based products, such as proteins and bio-sugars that contribute to modern molecular biology and biomedical research. In this study, the use of jack bean was evaluated as a source for concanavalin A (Con A) and bio-sugar production. A novel method for purifying Con A from JBs was successfully developed using a glucosylated magnetic nano matrix (GMNM) as a physical support, which facilitated easy separation and purification of Con A. In addition, the enzymatic conversion rate of 2% (w/v) Con A extracted residue to bio-sugar was 98.4%. Therefore, this new approach for the production of Con A and bio-sugar is potentially useful for obtaining bio-based products from jack bean. Copyright © 2016 Elsevier Ltd. All rights reserved.
Saber, Huda; Jasni, Azmiza Syawani; Jamaluddin, Tengku Zetty Maztura Tengku; Ibrahim, Rosni
2017-10-01
Coagulase-negative staphylococci (CoNS) are considered low pathogenic organisms. However, they are progressively causing more serious infections with time because they have adapted well to various antibiotics owing to their ability to form biofilms. Few studies have been conducted on CoNS in both, hospital and community-acquired settings, especially in Malaysia. Thus, it is important to study their species and gene distributions. A mobile genetic element, staphylococcal cassette chromosome mec (SCC mec ), plays an important role in staphylococci pathogenesis. Among CoNS, SCC mec has been studied less frequently than Staphylococcus aureus (coagulase-positive staphylococci). A recent study (8) conducted in Malaysia successfully detected SCC mec type I to VIII as well as several new combination patterns in CoNS species, particularly Staphylococcus epidermidis . However, data are still limited, and further research is warranted. This paper provides a review on SCC mec types among CoNS species.
Influence of eccentric actions on the metabolic cost of resistance exercise
NASA Technical Reports Server (NTRS)
Dudley, Gary A.; Golden, Catherine L.; Tesch, Per A.; Harris, Robert T.; Buchanan, Paul
1991-01-01
The contributions of concentric (con) and eccentric (ecc) muscle actions are evaluated with respect to increasing the metabolic cost of resistance exercise. Male subjects perform leg exercise with either con and ecc actions or only con actions while the net energy cost of the exercise is measured by oxygen consumption data. In both groups, the con actions require 290 J/kg body weight of total work, with an energy cost of 0.003 cal/J. The energy costs for the con/ecc actions of the second group is increased by 14 percent. The metabolic cost of leg exercise is concluded to be primarily generated by the con leg actions, and ecc leg actions increase the resistance with only a slight increase in required energy. The findings are significant for practical applications that emphasize the conservation of energy expenditure during exercise in spacecraft environments.
Elmore, M R P; Elischer, M F; Claeys, M C; Pajor, E A
2015-03-01
Raising beef cattle on concrete floors can negatively impact their welfare by increasing joint swelling and body lesions, as well as abnormalities in resting behavior and postural changes. We hypothesized that the addition of rubber mats to concrete pens would improve beef cattle welfare by improving performance, health, hygiene, and resting behavior. Forty-eight crossbred Angus steers were housed in pens of 4 and randomly assigned to a single flooring treatment: (1) fully slatted concrete (CON), (2) fully slatted rubber mat (SLAT), or (3) solid rubber mat (SOLID; 60% of pen floor) from 36 to 48 wk of age. Weight, ADG, lesions, gait score, joint swelling, and animal and pen cleanliness were collected every 2 wk. Behavioral time budgets and frequency of postural changes (an indicator of floor traction and comfort) were collected at 0, 6, and 12 wk. No differences in weight gain or ADG were observed. Steers on SOLID flooring (0.80 ± 0.08) showed increased lesions compared to SLAT (0.38 ± 0.08) and CON (0.37 ± 0.08; both, = 0.05); however, there was no difference between SLAT and CON. SLAT steers (1.69 ± 0.04) showed a reduced gait score compared to SOLID (1.95 ± 0.04) and CON (1.98 ± 0.04; both, < 0.05), but SOLID and CON did not differ. Steers on SLAT flooring had less joint swelling (both knees and hocks) compared to SOLID and CON (all comparisons, < 0.05), but SOLID and CON did not differ. Steers on SOLID (3.64 ± 0.05) flooring were dirtier than those on SLAT (2.27 ± 0.05) and CON (2.19 ± 0.05; both, < 0.001), whereas SLAT and CON were similar. Additionally, SOLID and SLAT pens were less clean than CON pens ( < 0.001 and = 0.094, respectively), and SOLID was less clean than SLAT ( < 0.001). Time budget behavior was affected by treatment ( = 0.043), where SOLID differed from CON and SLAT (both, < 0.05). Steers on SOLID flooring preferred to rest on the rubber mat vs. slatted concrete ( = 0.001). Steers on SLAT flooring changed their posture more frequently than those on SOLID and CON flooring (both, < 0.05), but SOLID and CON did not differ. Compared to CON steers, SOLID steers showed an increase in lesions and a reduction in cleanliness, whereas SLAT steers showed a decrease in gait score and joint swelling and an increase in postural changes. Combined, these data suggest that the addition of slatted rubber mats to concrete pens may improve beef cattle welfare.
Autonomous Formation Flying from Ground to Flight
NASA Technical Reports Server (NTRS)
Chapman, Keith B.; Dell, Gregory T.; Rosenberg, Duane L.; Bristow, John
1999-01-01
The cost of on-orbit operations remains a significant and increasingly visible concern in the support of satellite missions. Headway has been made in automating some ground operations; however, increased mission complexity and more precise orbital constraints have compelled continuing human involvement in mission design and maneuver planning operations. AI Solutions, Inc. in cooperation with the National Aeronautics and Space Administration's (NASA) Goddard Space Flight Center (GSFC) has tackled these more complex problems through the development of AutoCon as a tool for an automated solution. NASA is using AutoCon to automate the maneuver planning for the Earth Orbiter-1 (EO-1) mission. AutoCon was developed originally as a ground system tool. The EO-1 mission will be using a scaled version of AutoCon on-board the EO-1 satellite to command orbit adjustment maneuvers. The flight version of AutoCon plans maneuvers based on formation flying algorithms developed by GSFC, JPL, and other industry partners. In its fully autonomous mode, an AutoCon planned maneuver will be executed on-board the satellite without intervention from the ground. This paper describes how AutoCon automates maneuver planning for the formation flying constraints of the EO-1 mission. AutoCon was modified in a number of ways to automate the maneuver planning on-board the satellite. This paper describes how the interface and functionality of AutoCon were modified to support the on-board system. A significant component of this modification was the implementation of a data smoother, based on a Kalman filter, that ensures that the spacecraft states estimated by an on-board GPS receiver are as accurate as possible for maneuver planning. This paper also presents the methodology use to scale the AutoCon functionality to fit and execute on the flight hardware. This paper also presents the modes built that allow the incremental phasing in of autonomy. New technologies for autonomous operations are usually received with significant, and probably appropriate trepidation. A number of safeguards have been designed in both AutoCon and the interfacing systems to alleviate the potential of mission-impacting anomalies from the on-board autonomous system. This paper describes the error checking, input data integrity validation and limits set on maneuvers in AutoCon and the on-board system.
Autonomous Formation Flying from the Ground to Flight
NASA Technical Reports Server (NTRS)
Chapman, Keith B.; Dell, Gregory T.; Rosenberg, Duane L.; Bristow, John
1999-01-01
The cost of on-orbit operations remains a significant and increasingly visible concern in the support of satellite missions. Headway has been made in automating some ground operations; however, increased mission complexity and more precise orbital constraints have compelled continuing human involvement in mission design and maneuver planning operations. AI Solutions, Inc. in cooperation with the National Aeronautics and Space Administration's (NASA) Goddard Space Flight Center (GSFC) has tackled these more complex problems through the development of AutoCon(TM) as a tool for an automated solution. NASA is using AutoCon(TM) to automate the maneuver planning for the Earth Orbiter-1 (EO-1) mission. AutoCon(TM) was developed originally as a ground system tool. The EO-1 mission will be using a scaled version of AutoCon(TM) on-board the EO-1 satellite to command orbit adjustment maneuvers. The flight version of AutoCon(TM) plans maneuvers based on formation flying algorithms developed by GSFC, JPL, and other industry partners. In its fully autonomous mode, an AutoCon(TM) planned maneuver will be executed on-board the satellite without intervention from the ground. This paper describes how AutoCon(TM) automates maneuver planning for the formation flying constraints of the EO-1 mission. AutoCon(TM) was modified in a number of ways to automate the maneuver planning on-board the satellite. This paper describes how the interface and functionality of AutoCon(TM) were modified to support the on-board system. A significant component of this modification was the implementation of a data smoother, based on a Kalman filter, that ensures that the spacecraft states estimated by an on-board GPS receiver are as accurate as possible for maneuver planning. This paper also presents the methodology used to scale the AutoCon(TM) functionality to fit and execute on the flight hardware. This paper also presents the modes built into the system that allow the incremental phasing in of autonomy. New technologies for autonomous operations are usually received with significant, and probably appropriate, trepidation. A number of safeguards have been designed in both AutoCon(TM) and the interfacing systems to alleviate the potential of mission-impacting anomalies from the on-board autonomous system. This paper describes the error checking, input data integrity validation, and limits set on maneuvers in AutoCon(TM) and the on-board system.
Hulot, Sandrine L.; Korber, Bette; Giorgi, Elena E.; Vandergrift, Nathan; Saunders, Kevin O.; Balachandran, Harikrishnan; Mach, Linh V.; Lifton, Michelle A.; Pantaleo, Giuseppe; Tartaglia, Jim; Phogat, Sanjay; Jacobs, Bertram; Kibler, Karen; Perdiguero, Beatriz; Gomez, Carmen E.; Esteban, Mariano; Rosati, Margherita; Felber, Barbara K.; Pavlakis, George N.; Parks, Robert; Lloyd, Krissey; Sutherland, Laura; Scearce, Richard; Letvin, Norman L.; Seaman, Michael S.; Alam, S. Munir; Montefiori, David; Liao, Hua-Xin; Haynes, Barton F.
2015-01-01
ABSTRACT An effective human immunodeficiency virus type 1 (HIV-1) vaccine must induce protective antibody responses, as well as CD4+ and CD8+ T cell responses, that can be effective despite extraordinary diversity of HIV-1. The consensus and mosaic immunogens are complete but artificial proteins, computationally designed to elicit immune responses with improved cross-reactive breadth, to attempt to overcome the challenge of global HIV diversity. In this study, we have compared the immunogenicity of a transmitted-founder (T/F) B clade Env (B.1059), a global group M consensus Env (Con-S), and a global trivalent mosaic Env protein in rhesus macaques. These antigens were delivered using a DNA prime-recombinant NYVAC (rNYVAC) vector and Env protein boost vaccination strategy. While Con-S Env was a single sequence, mosaic immunogens were a set of three Envs optimized to include the most common forms of potential T cell epitopes. Both Con-S and mosaic sequences retained common amino acids encompassed by both antibody and T cell epitopes and were central to globally circulating strains. Mosaics and Con-S Envs expressed as full-length proteins bound well to a number of neutralizing antibodies with discontinuous epitopes. Also, both consensus and mosaic immunogens induced significantly higher gamma interferon (IFN-γ) enzyme-linked immunosorbent spot assay (ELISpot) responses than B.1059 immunogen. Immunization with these proteins, particularly Con-S, also induced significantly higher neutralizing antibodies to viruses than B.1059 Env, primarily to tier 1 viruses. Both Con-S and mosaics stimulated more potent CD8-T cell responses against heterologous Envs than did B.1059. Both antibody and cellular data from this study strengthen the concept of using in silico-designed centralized immunogens for global HIV-1 vaccine development strategies. IMPORTANCE There is an increasing appreciation for the importance of vaccine-induced anti-Env antibody responses for preventing HIV-1 acquisition. This nonhuman primate study demonstrates that in silico-designed global HIV-1 immunogens, designed for a human clinical trial, are capable of eliciting not only T lymphocyte responses but also potent anti-Env antibody responses. PMID:25855741
Pawanindra, Lal; Vindal, Anubhav; Midha, Manoj; Nagpal, Prashant; Manchanda, Alpana; Chander, Jagdish
2015-10-01
Pre- and post-operative stomach volumes can be important determinants for effectiveness of laparoscopic sleeve gastrectomy (LSG) in causing weight loss. There is little existing data on the volumes of stomach preoperatively and that excised during LSG. This study was designed to evaluate the change in gastric volume after LSG using multi-detector CT and to correlate it with early post-operative weight loss. Twenty consecutive patients with BMI ≥ 40 kg/m(2) and medical comorbidities underwent LSG between October 2011 and October 2013 and were analysed prospectively. The pre-operative stomach volume was measured by MDCT done 1-3 days before the surgery. LSG was performed in the standard manner using a 36F bougie. The volume of excised stomach was measured by distending the specimen with saline. MDCT of the upper abdomen was repeated 3 months postoperatively to calculate the gastric sleeve volume. Weight loss and resolution of comorbidities were documented. The mean pre-operative weight of patients was 123.90 kg, and the mean pre-operative stomach volume on MDCT was 1,067 ml. The stomach volume on pre-operative MDCT correlated with pre-operative weight and BMI. The mean volume of the excised stomach was 859 ml when measured by distension of the specimen and 850 ml on MDCT. After 3 months post surgery, the mean volume of gastric sleeve on MDCT was 217 ml, and the mean weight of the patients was 101.22 kg. The volume of the excised stomach calculated by MDCT correlated with the weight loss achieved 3 months postoperatively. However, no correlation was seen between the gastric sleeve volume 3 months postoperatively and weight loss during this period. MDCT is a good method to measure gastric volume before and after LSG. Early post-operative weight loss (3 months) correlates well with the volume of the excised stomach but not with that of the gastric sleeve.
NASA Astrophysics Data System (ADS)
Angel, Erin
Advances in Computed Tomography (CT) technology have led to an increase in the modality's diagnostic capabilities and therefore its utilization, which has in turn led to an increase in radiation exposure to the patient population. As a result, CT imaging currently constitutes approximately half of the collective exposure to ionizing radiation from medical procedures. In order to understand the radiation risk, it is necessary to estimate the radiation doses absorbed by patients undergoing CT imaging. The most widely accepted risk models are based on radiosensitive organ dose as opposed to whole body dose. In this research, radiosensitive organ dose was estimated using Monte Carlo based simulations incorporating detailed multidetector CT (MDCT) scanner models, specific scan protocols, and using patient models based on accurate patient anatomy and representing a range of patient sizes. Organ dose estimates were estimated for clinical MDCT exam protocols which pose a specific concern for radiosensitive organs or regions. These dose estimates include estimation of fetal dose for pregnant patients undergoing abdomen pelvis CT exams or undergoing exams to diagnose pulmonary embolism and venous thromboembolism. Breast and lung dose were estimated for patients undergoing coronary CTA imaging, conventional fixed tube current chest CT, and conventional tube current modulated (TCM) chest CT exams. The correlation of organ dose with patient size was quantified for pregnant patients undergoing abdomen/pelvis exams and for all breast and lung dose estimates presented. Novel dose reduction techniques were developed that incorporate organ location and are specifically designed to reduce close to radiosensitive organs during CT acquisition. A generalizable model was created for simulating conventional and novel attenuation-based TCM algorithms which can be used in simulations estimating organ dose for any patient model. The generalizable model is a significant contribution of this work as it lays the foundation for the future of simulating TCM using Monte Carlo methods. As a result of this research organ dose can be estimated for individual patients undergoing specific conventional MDCT exams. This research also brings understanding to conventional and novel close reduction techniques in CT and their effect on organ dose.
Colombi, Davide; Dinkel, Julien; Weinheimer, Oliver; Obermayer, Berenike; Buzan, Teodora; Nabers, Diana; Bauer, Claudia; Oltmanns, Ute; Palmowski, Karin; Herth, Felix; Kauczor, Hans Ulrich; Sverzellati, Nicola
2015-01-01
Objectives To describe changes over time in extent of idiopathic pulmonary fibrosis (IPF) at multidetector computed tomography (MDCT) assessed by semi-quantitative visual scores (VSs) and fully automatic histogram-based quantitative evaluation and to test the relationship between these two methods of quantification. Methods Forty IPF patients (median age: 70 y, interquartile: 62-75 years; M:F, 33:7) that underwent 2 MDCT at different time points with a median interval of 13 months (interquartile: 10-17 months) were retrospectively evaluated. In-house software YACTA quantified automatically lung density histogram (10th-90th percentile in 5th percentile steps). Longitudinal changes in VSs and in the percentiles of attenuation histogram were obtained in 20 untreated patients and 20 patients treated with pirfenidone. Pearson correlation analysis was used to test the relationship between VSs and selected percentiles. Results In follow-up MDCT, visual overall extent of parenchymal abnormalities (OE) increased in median by 5 %/year (interquartile: 0 %/y; +11 %/y). Substantial difference was found between treated and untreated patients in HU changes of the 40th and of the 80th percentiles of density histogram. Correlation analysis between VSs and selected percentiles showed higher correlation between the changes (Δ) in OE and Δ 40th percentile (r=0.69; p<0.001) as compared to Δ 80th percentile (r=0.58; p<0.001); closer correlation was found between Δ ground-glass extent and Δ 40th percentile (r=0.66, p<0.001) as compared to Δ 80th percentile (r=0.47, p=0.002), while the Δ reticulations correlated better with the Δ 80th percentile (r=0.56, p<0.001) in comparison to Δ 40th percentile (r=0.43, p=0.003). Conclusions There is a relevant and fully automatically measurable difference at MDCT in VSs and in histogram analysis at one year follow-up of IPF patients, whether treated or untreated: Δ 40th percentile might reflect the change in overall extent of lung abnormalities, notably of ground-glass pattern; furthermore Δ 80th percentile might reveal the course of reticular opacities. PMID:26110421
Kudo, Tomoaki; Kuratani, Toru; Shimamura, Kazuo; Sakamoto, Tomohiko; Kin, Keiwa; Masada, Kenta; Shijo, Takayuki; Torikai, Kei; Maeda, Koichi; Sawa, Yoshiki
2017-10-01
Type 1a endoleak is one of the most severe complications after thoracic endovascular aortic repair (TEVAR), because it carries the risk of aortic rupture. The association between bird-beak configuration and Type 1a endoleak remains unclear. The purpose of this study was to analyse the predictors of Type 1a endoleak following Zone 1 and Zone 2 TEVAR, with a particular focus on the effect of bird-beak configuration. From April 2008 to July 2015, 105 patients (mean age 68.6 years) who underwent Zone 1 and 2 landing TEVAR were enrolled, with a mean follow-up period of 4.3 years. The patients were categorized into 2 groups, according to the presence (Group B, n = 32) or the absence (Group N, n = 73) of bird-beak configuration on the first postoperative multidetector computed tomography. The Kaplan-Meier event-free rate curve showed that Type 1a endoleak and bird-beak progression occurred less frequently in Group N than in Group B. Five-year freedom from Type 1a endoleak rates were 79.7% and 100% for Groups B and N, respectively (P = 0.007). Multivariable logistic regression analysis showed that dissecting aortic aneurysm (odds ratio 3.72, 95% confidence interval 1.30-11.0; P = 0.014) and shorter radius of inner curvature (odds ratio 1.09, 95% confidence interval 0.85-0.99; P = 0.025) were significant risk factors for bird-beak configuration. Multivariable Cox proportional hazard regression showed that Z-type stent graft (hazard ratio 2.69, 95% confidence interval 1.11-6.51; P = 0.030) was a significant risk factor for bird-beak progression. Appropriate stent grafts need to be chosen carefully to prevent Type 1a endoleak and bird-beak configuration after landing Zone 1 and 2 TEVAR. Patients with bird-beak configuration on early postoperative multidetector computed tomography require closer follow-up to screen for Type 1a endoleak. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
2010-01-01
Introduction In recent years, several massive earthquakes have occurred across the globe. Multidetector computed tomography (MDCT) is reliable in detecting spinal injuries. The purpose of this study was to compare the features of spinal injuries resulting from the Sichuan earthquake with those of non-earthquake-related spinal trauma using MDCT. Methods Features of spinal injuries of 223 Sichuan earthquake-exposed patients and 223 non-earthquake-related spinal injury patients were retrospectively compared using MDCT. The date of non-earthquake-related spinal injury patients was collected from 1 May 2009 to 22 July 2009 to avoid the confounding effects of seasonal activity and clothing. We focused on anatomic sites, injury types and neurologic deficits related to spinal injuries. Major injuries were classified according to the grid 3-3-3 scheme of the Magerl (AO) classification system. Results A total of 185 patients (82.96%) in the earthquake-exposed cohort experienced crush injuries. In the earthquake and control groups, 65 and 92 patients, respectively, had neurologic deficits. The anatomic distribution of these two cohorts was significantly different (P < 0.001). Cervical spinal injuries were more common in the control group (risk ratio (RR) = 2.12, P < 0.001), whereas lumbar spinal injuries were more common in the earthquake-related spinal injuries group (277 of 501 injured vertebrae; 55.29%). The major types of injuries were significantly different between these cohorts (P = 0.002). Magerl AO type A lesions composed most of the lesions seen in both of these cohorts. Type B lesions were more frequently seen in earthquake-related spinal injuries (RR = 1.27), while we observed type C lesions more frequently in subjects with non-earthquake-related spinal injuries (RR = 1.98, P = 0.0029). Conclusions Spinal injuries sustained in the Sichuan earthquake were located mainly in the lumbar spine, with a peak prevalence of type A lesions and a high occurrence of neurologic deficits. The anatomic distribution and type of spinal injuries that varied between earthquake-related and non-earthquake-related spinal injury groups were perhaps due to the different mechanism of injury. PMID:21190568
Jones, Jeryl C; Appt, Susan E; Werre, Stephen R; Tan, Joshua C; Kaplan, Jay R
2010-06-01
The purpose of this study was to validate low radiation dose, contrast-enhanced, multi-detector computed tomography (MDCT) as a non-invasive method for measuring ovarian volume in macaques. Computed tomography scans of four known-volume phantoms and nine mature female cynomolgus macaques were acquired using a previously described, low radiation dose scanning protocol, intravenous contrast enhancement, and a 32-slice MDCT scanner. Immediately following MDCT, ovaries were surgically removed and the ovarian weights were measured. The ovarian volumes were determined using water displacement. A veterinary radiologist who was unaware of actual volumes measured ovarian CT volumes three times, using a laptop computer, pen display tablet, hand-traced regions of interest, and free image analysis software. A statistician selected and performed all tests comparing the actual and CT data. Ovaries were successfully located in all MDCT scans. The iliac arteries and veins, uterus, fallopian tubes, cervix, ureters, urinary bladder, rectum, and colon were also consistently visualized. Large antral follicles were detected in six ovaries. Phantom mean CT volume was 0.702+/-SD 0.504 cc and the mean actual volume was 0.743+/-SD 0.526 cc. Ovary mean CT volume was 0.258+/-SD 0.159 cc and mean water displacement volume was 0.257+/-SD 0.145 cc. For phantoms, the mean coefficient of variation for CT volumes was 2.5%. For ovaries, the least squares mean coefficient of variation for CT volumes was 5.4%. The ovarian CT volume was significantly associated with actual ovarian volume (ICC coefficient 0.79, regression coefficient 0.5, P=0.0006) and the actual ovarian weight (ICC coefficient 0.62, regression coefficient 0.6, P=0.015). There was no association between the CT volume accuracy and mean ovarian CT density (degree of intravenous contrast enhancement), and there was no proportional or fixed bias in the CT volume measurements. Findings from this study indicate that MDCT is a valid non-invasive technique for measuring the ovarian volume in macaques.
Arslan, Harun; Fatih Özbay, Mehmet; Çallı, İskan; Doğan, Erkan; Çelik, Sebahattin; Batur, Abdussamet; Bora, Aydın; Yavuz, Alpaslan; Bulut, Mehmet Deniz; Özgökçe, Mesut; Çetin Kotan, Mehmet
2017-03-01
Diagnostic performance of Diffusion-Weighted magnetic resonance Imaging (DWI) and Multi-Detector Computed Tomography (MDCT) for TNM (Tumor, Lymph node, Metastasis) staging of gastric cancer was compared. We used axial T2-weighted images and DWI (b-0,400 and b-800 s/mm2) protocol on 51 pre-operative patients who had been diagnosed with gastric cancer. We also conducted MDCT examinations on them. We looked for a signal increase in the series of DWI images. The depth of tumor invasion in the stomach wall (tumor (T) staging), the involvement of lymph nodes (nodal (N) staging), and the presence or absence of metastases (metastatic staging) in DWI and CT images according to the TNM staging system were evaluated. In each diagnosis of the tumors, sensitivity, specificity, positive and negative accuracy rates of DWI and MDCT examinations were found through a comparison with the results of the surgical pathology, which is the gold standard method. In addition to the compatibilities of each examination with surgical pathology, kappa statistics were used. Sensitivity and specificity of DWI and MDCT in lymph node staging were as follows: N1: DWI: 75.0%, 84.6%; MDCT: 66.7%, 82%;N2: DWI: 79.3%, 77.3%; MDCT: 69.0%, 68.2%; N3: DWI: 60.0%, 97.6%; MDCT: 50.0%, 90.2%. The diagnostic tool DWI seemed more compatible with the gold standard method (surgical pathology), especially in the staging of lymph node, when compared to MDCT. On the other hand, in T staging, the results of DWI and MDCT were better than the gold standard when the T stage increased. However, DWI did not demonstrate superiority to MDCT. The sensitivity and specificity of both imaging techniques for detecting distant metastasis were 100%. The diagnostic accuracy of DWI for TNM staging in gastric cancer before surgery is at a comparable level with MDCT and adding DWI to routine protocol of evaluating lymph nodes metastasis might increase diagnostic accuracy.
Camera, Luigi; Romano, Federica; Liccardo, Immacolata; Liuzzi, Raffaele; Imbriaco, Massimo; Mainenti, Pier Paolo; Pizzuti, Laura Micol; Segreto, Sabrina; Maurea, Simone; Brunetti, Arturo
2015-11-01
As both contrast and radiation dose affect the quality of CT images, a constant image quality in abdominal contrast-enhanced multidetector computed tomography (CE-MDCT) could be obtained balancing radiation and contrast media dose according to the age of the patients. Seventy-two (38 Men; 34 women; aged 20-83 years) patients underwent a single-pass abdominal CE-MDCT. Patients were divided into three different age groups: A (20-44 years); B (45-65 years); and C (>65 years). For each group, a different noise index (NI) and contrast media dose (370 mgI/mL) was selected as follows: A (NI, 15; 2.5 mL/kg), B (NI, 12.5; 2 mL/kg), and C (NI, 10; 1.5 mL/kg). Radiation exposure was reported as dose-length product (DLP) in mGy × cm. For quantitative analysis, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated for both the liver (L) and the abdominal aorta (A). Statistical analysis was performed with a one-way analysis of variance. Standard imaging criteria were used for qualitative analysis. Although peak hepatic enhancement was 152 ± 16, 128 ± 12, and 101 ± 14 Hounsfield units (P < .001) for groups A, B, and C, respectively, no significant differences were observed in the corresponding SNRL with 9.2 ± 1.4, 9.1 ± 1.2, and 9.2 ± 3. Radiation (mGy × cm) and contrast media dose (mL) administered were 476 ± 147 and 155 ± 27 for group A, 926 ± 291 and 130 ± 16 for group B, and 1981 ± 451 and 106 ± 15 for group C, respectively (P < .001). None of the studies was graded as poor or inadequate by both readers, and the prevalence-adjusted bias-adjusted kappa ranged between 0.48 and 0.93 for all but one criteria. A constant image quality in CE-MDCT can be obtained balancing radiation and contrast media dose administered to patients of different age. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
The Procurement of Non Developmental Items: Pros and Cons
1994-09-01
commercial way of procurement will bring more advantages than disadvantages to DOD. The list of the pros greatly outweighs the cons . There is practically...AD-A285 009 MH PROCUREMENT OF NON DEVELOPMENTAL ITEMS: PROS AND CONS THES IS Giorgio Scappaticci. Lt. Col., Italian Air Force AFIT/GLMILALj94S-3 I...PROS AND CONS U;narmou,.ced 0 Justification THESIS Giorgio Scappaticci, Lt. Col., Italian Air Force Dist’ibution f Availability Codes AFIT/GLM/LAL
1982-04-22
acquisition would be an obligation made by the Environmental Protection Agency to a State to aid in the construction of a sewage treatment plant ...DE 1 PINELLAS COUNTY-TREASURE IS. CON FT... 3 FIRE IS. INLET TO JONES BEACH CON NY 2 TOTAL ESTIMATED COST CURRENT BASELINE...HELLFIRE MISSILE SYSTEM EQP OH 418 :I:ND WASTE TREATMENT PLANT CON TN 345 HOSPITAL IMPROVEMENTS FT HOOD CON TX 339 MLRS
Henis, Y I; Elson, E L
1981-01-01
Fluorescence photobleaching recovery was used to study directly and quantitatively the inhibition of the lateral mobility of surface immunoglobulins (sIg) on mouse lymphocytes by localized binding of concanavalin A (Con A) coupled to platelets. Up to a threshold occupancy of about 10% of the upper cell surface by Con A-platelets, the diffusion coefficient and mobile fraction of sIg remained as in untreated cells (5.3 X 10(-10) cm2/sec and 0.65, respectively). At higher surface occupancy, these values decreased to 8 X 10(-11) cm2/sec and 0.11. The magnitude of the effect was independent of the percentage occupancy above the threshold and of the distance from the bound Con A-platelets, indicating a cooperative and propagated phenomenon. Treatment with colchicine or cytochalasin B separately induced only partial reversal of the Con A-induced modulation. Treatment with both reversal of the Con A-induced modulation. Treatment with both drugs together was synergistic and fully reversed the mobility inhibition. The modulation was unaffected by NaN3 and 2-deoxyglucose, suggesting no dependence on metabolic energy. Con A-platelets did not affect the mobility of a lipid probe. Models for the Con A-induced modulation and the relationship between the effects of Con A on sIg mobility and patch formation are discussed. PMID:6940124
Xu, Shizan; Wu, Liwei; Zhang, Qinghui; Feng, Jiao; Li, Sainan; Li, Jingjing; Liu, Tong; Mo, Wenhui; Wang, Wenwen; Lu, Xiya; Yu, Qiang; Chen, Kan; Xia, Yujing; Lu, Jie; Xu, Ling; Zhou, Yingqun; Fan, Xiaoming; Guo, Chuanyong
2017-09-15
Propylene glycol alginate sodium sulfate (PSS), a sulfated polysaccharide possesses anti-inflammatory effects. Here, we investigated the effect of PSS on concanavalin A (Con A)-induced liver injury in mice and examined the underlying mechanisms. Balb/C mice were injected intravenously with Con A (25mg/kg) to generate a model of acute liver injury. PSS (25 or 50mg/kg) was injected intraperitoneally 1h before the Con A administration. The levels of serum liver enzymes, inflammatory cytokines, and other marker proteins were determined, and liver injury was assessed histopathologically 2, 8, and 24h after Con A injection. Pretreatment with PSS reduced the levels of serum liver enzymes, inflammatory cytokines such as tumor necrosis factor (TNF)-α and interleukin (IL)-1β, and attenuated histopathological damage in Con A-induced liver injury in mice. The effects of Con A were mediated by apoptosis and autophagy, as indicated by changes in protein and gene expression of related factors after Con A injection. PSS activated the phosphatidylinositol 3-kinase (PI3K)/protein kinase B (Akt) pathway and showed a protective function against apoptosis and autophagy. PSS ameliorated Con A-induced liver injury by downregulating inflammatory cytokines including TNF-α and IL-1β and regulating apoptosis and autophagy via the PI3K/Akt pathway. Copyright © 2017 Elsevier Inc. All rights reserved.
Mella-Herrera, Rodrigo A; Neunuebel, M Ramona; Golden, James W
2011-03-01
The conR (all0187) gene of the filamentous cyanobacterium Anabaena (Nostoc) sp. strain PCC 7120 is predicted to be part of a family of proteins that contain the LytR-CpsA-Psr domain associated with septum formation and cell wall maintenance. The conR gene was originally misannotated as a transcription regulator. Northern RNA blot analysis showed that conR expression was upregulated 8 h after nitrogen step-down. Fluorescence microscopy of a P(conR)-gfp reporter strain revealed increased GFP fluorescence in proheterocysts and heterocysts beginning 9 h after nitrogen step-down. Insertional inactivation of conR caused a septum-formation defect of vegetative cells grown in nitrate-containing medium. In nitrate-free medium, mutant filaments formed abnormally long heterocysts and were defective for diazotrophic growth. Septum formation between heterocysts and adjacent vegetative cells was abnormal, often with one or both poles of the heterocysts appearing partially open. In a conR mutant, expression of nifH was delayed after nitrogen step-down and nitrogenase activity was approximately 70 % of wild-type activity, indicating that heterocysts of the conR mutant strain are partially functional. We hypothesize that the diazotrophic growth defect is caused by an inability of the heterocysts to transport fixed nitrogen to the neighbouring vegetative cells.
Salidroside mediates apoptosis and autophagy inhibition in concanavalin A-induced liver injury
Feng, Jiao; Niu, Peiqin; Chen, Kan; Wu, Liwei; Liu, Tong; Xu, Shizan; Li, Jingjing; Li, Sainan; Wang, Wenwen; Lu, Xiya; Yu, Qiang; Liu, Ning; Xu, Ling; Wang, Fan; Dai, Weiqi; Xia, Yujing; Fan, Xiaoming; Guo, Chuanyong
2018-01-01
Salidroside (Sal) is a glycoside extract from Rhodiola rosea L. with anti-inflammatory, antioxidant, anticancer and cardioprotective properties. The present study explored the protective effects and the possible mechanisms of Sal on concanavalin A (ConA)-induced liver injury in mice. Balb/C mice were divided into five groups: Normal control (injected with normal saline), ConA (25 mg/kg), Sal (10 mg/kg) +ConA, Sal (20 mg/kg) + ConA (Sal injected 2 h prior to ConA injection) and Sal (20 mg/kg) only. The serum levels of liver enzymes, pro-inflammatory cytokines, and apoptosis- and autophagy-associated marker proteins were determined at 2, 8 and 24 h after ConA injection. LY294002 was further used to verify whether the phosphoinositide 3-kinase (PI3K)/Akt pathway was activated. Primary hepatocytes were isolated to verify the effect of Sal in vitro. The results indicated that Sal was a safe agent to reduce pathological damage and serum liver enzymes in ConA-induced liver injury. Sal suppressed inflammatory reactions in serum and liver tissues, and activated the PI3K/Akt signaling pathway to inhibit apoptosis and autophagy in vivo and in vitro, which could be reversed by LY294002. In conclusion, Sal attenuated ConA-induced liver injury by modulating PI3K/Akt pathway-mediated apoptosis and autophagy in mice.
NASA Astrophysics Data System (ADS)
Esselman, Brian J.; Amberger, Brent K.; Nolan, Alex M.; Woods, R. Claude; McMahon, R. J.
2011-10-01
Intrigued by the reported 2005 synthesis of diazirinone (1), we carried out further experimental and theoretical studies aimed at the detailed matrix-isolation and millimeter-wave spectroscopic characterizations of 1. Diazirinone (1) is a peculiar isoconjugate of two very stable molecules and may be of astrochemical interest. Unfortunately, the original reported methods of diazirinone (1) generation did not yield this species, rather its decomposition products. Inspired by a more recent gas phase pyrolysis of CON6 (2) to yield CON2 (1), we proposed a new method of generating CON6 (2) in solution as a precursor of diazirinone (1). This new synthesis may allow us to generate larger quantities of both CON6 and CON2 for investigation by millimeter-wave spectroscopy. We are able to safely generate carbonyl diazide (2) in sufficient yield from the reaction of triphosgene (3) and tetrabutylammonium azide in diethyl ether. This has allowed us to obtain both matrix-isolation and gas phase IR spectra of carbonyl diazide (2). After purification, it has a gas-phase lifetime that allows samples to be useable for up to several weeks. However, it is a shock-sensitive material that must be handled with care to prevent violent decomposition. In order to provide better mechanistic insight into the decomposition of carbonyl diazide (2) to diazirinone (1), we have engaged in a DFT and ab initio computational study. We have found a pathway between the two species via the triplet acylnitrene, CON4, and an oxaziridine CON2 species, but not at sufficiently low energies to allow for the trapping and detection of diazirinone (1). Preliminary millimeter-wave spectra have been obtained from several synthesized and purified samples of CON6 (2). However, the assignment of the spectra lines has been unexpectedly problematic. We have placed several CON6 (2) samples, confirmed by IR spectroscopy at the time of sample loading, into our instrument and obtained two different sets of rotational lines. This rotational puzzle will be investigated further with a significantly upgraded millimeter-wave spectrometer.
Gibson, Oliver R; Turner, Gareth; Tuttle, James A; Taylor, Lee; Watt, Peter W; Maxwell, Neil S
2015-10-15
Heat acclimation (HA) attenuates physiological strain in hot conditions via phenotypic and cellular adaptation. The aim of this study was to determine whether HA reduced physiological strain, and heat shock protein (HSP) 72 and HSP90α mRNA responses in acute normobaric hypoxia. Sixteen male participants completed ten 90-min sessions of isothermic HA (40°C/40% relative humidity) or exercise training [control (CON); 20°C/40% relative humidity]. HA or CON were preceded (HYP1) and proceeded (HYP2) by a 30-min normobaric hypoxic exposure [inspired O2 fraction = 0.12; 10-min rest, 10-min cycling at 40% peak O2 uptake (V̇O2 peak), 10-min cycling at 65% V̇O2 peak]. HA induced greater rectal temperatures, sweat rate, and heart rates (HR) than CON during the training sessions. HA, but not CON, reduced resting rectal temperatures and resting HR and increased sweat rate and plasma volume. Hemoglobin mass did not change following HA nor CON. HSP72 and HSP90α mRNA increased in response to each HA session, but did not change with CON. HR during HYP2 was lower and O2 saturation higher at 65% V̇O2 peak following HA, but not CON. O2 uptake/HR was greater at rest and 65% V̇O2 peak in HYP2 following HA, but was unchanged after CON. At rest, the respiratory exchange ratio was reduced during HYP2 following HA, but not CON. The increase in HSP72 mRNA during HYP1 did not occur in HYP2 following HA. In CON, HSP72 mRNA expression was unchanged during HYP1 and HYP2. In HA and CON, increases in HSP90α mRNA during HYP1 were maintained in HYP2. HA reduces physiological strain, and the transcription of HSP72, but not HSP90α mRNA in acute normobaric hypoxia. Copyright © 2015 the American Physiological Society.
Planificación Neuroquirúrgica con Software Osirix
Jaimovich, Sebastián Gastón; Guevara, Martin; Pampin, Sergio; Jaimovich, Roberto; Gardella, Javier Luis
2014-01-01
Introducción: La individualidad anatómica es clave para reducir el trauma quirúrgico y obtener un mejor resultado. Actualmente, el avance en las neuroimágenes ha permitido objetivar esa individualidad anatómica, permitiendo planificar la intervención quirúrgica. Con este objetivo, presentamos nuestra experiencia con el software Osirix. Descripción de la técnica: Se presentan 3 casos ejemplificadores de 40 realizados. Caso 1: Paciente con meningioma de la convexidad parasagital izquierda en área premotora; Caso 2: Paciente con macroadenoma hipofisario, operada previamente por vía transeptoesfenoidal en otra institución con una resección parcial; Caso 3: Paciente con lesiones en pedúnculo cerebeloso medio bilateral. Se realizó la planificación prequirúrgica con el software OsiriX, fusionando y reconstruyendo en 3D las imágenes de TC e IRM, para analizar relaciones anatómicas, medir distancias, coordenadas y trayectorias, entre otras funciones. Discusión: El software OsiriX de acceso libre y gratuito permite al cirujano, mediante la fusión y reconstrucción en 3D de imágenes, analizar la anatomía individual del paciente y planificar de forma rápida, simple, segura y económica cirugías de alta complejidad. En el Caso 1 se pudo analizar las relaciones del tumor con las estructuras adyacentes para minimizar el abordaje. En el Caso 2 permitió comprender la anatomía post-operatoria previa del paciente, para determinar la trayectoria del abordaje transnasal endoscópico y la necesidad de ampliar su exposición, logrando la resección tumoral completa. En el Caso 3 permitió obtener las coordenadas estereotáxicas y trayectoria de una lesión sin representación tomográfica. Conclusión: En casos de no contar con costosos sistemas de neuronavegación o estereotáxia el software OsiriX es una alternativa a la hora de planificar la cirugía, con el objetivo de disminuir el trauma y la morbilidad operatoria. PMID:25165617
Poonacha, Nethravathi; Nair, Sandhya; Desai, Srividya; Tuppad, Darshan; Hiremath, Deepika; Mohan, Thulasi; Vipra, Aradhana
2017-01-01
ABSTRACT Coagulase-negative staphylococci (CoNS) are the major causative agents of foreign-body-related infections, including catheter-related bloodstream infections. Because of the involvement of biofilms, foreign-body-related infections are difficult to treat. P128, a chimeric recombinant phage-derived ectolysin, has been shown to possess bactericidal activity on strains of Staphylococcus aureus, including methicillin-resistant S. aureus (MRSA). We tested the killing potential of P128 on three clinically significant species of CoNS, S. epidermidis, S. haemolyticus, and S. lugdunensis, under a variety of physiological conditions representing growing and nongrowing states. The MIC90 and minimum bactericidal concentration at which 90% of strains tested are killed (MBC90) of P128 on 62 clinical strains of CoNS were found to be 16 and 32 μg/ml (0.58 and 1.16 μM), respectively, demonstrating the bactericidal nature of P128 on CoNS strains. Serum showed a potentiating effect on P128 inhibition, as indicated by 4- to 32-fold lower MIC values observed in serum. P128 caused a rapid loss of viability in all CoNS strains tested. Persisters of CoNS that were enriched in the presence of vancomycin or daptomycin were killed by P128 at 1× the MIC in a rapid manner. Low concentrations of P128 caused a 2- to 5-log reduction in CFU in stationary-phase or poorly metabolizing CoNS cultures. P128 at low concentrations eliminated CoNS biofilms in microtiter plates and on the surface of catheters. Combinations of P128 and standard-of-care (SoC) antibiotics were highly synergistic in inhibiting growth in preformed biofilms. Potent activity on planktonic cells, persisters, and biofilms of CoNS suggests that P128 is a promising candidate for the clinical development of treatments for foreign-body-related and other CoNS infections. PMID:28559263
The role of the 2H4 molecule in the generation of suppressor function in Con A-activated T cells.
Morimoto, C; Letvin, N L; Rudd, C E; Hagan, M; Takeuchi, T; Schlossman, S F
1986-11-15
The molecular basis for the suppression generated in a concanavalin A (Con A)-activated T cell culture remains unknown. In this study, we have attempted to determine whether the 2H4 and 4B4 molecules on Con A-activated T cells play some role in the generation of suppression by such cells. We have shown that Con A-activated suppressor cells belong to the 2H4+ subset of T cells but not the 4B4+ (2H4-) subset. Con A-activated T cells exerted their optimal suppressor function on day 2 in culture, a time at which the expression of 2H4 on such cells was maximal and 4B4 was minimal. Furthermore, the stimulation of T cells with the higher concentration of Con A generated the stronger suppressor function. At the same time, both 2H4 expression and density were increased and 4B4 expression and density were decreased on such Con A-activated T cells. More importantly, the treatment of Con A-activated T cells with anti-2H4 antibody but not with anti-4B4, anti-TQ1, or anti-T4 antibodies can block the suppressor function of such cells. Taken together, the above results strongly suggest that the 2H4 molecule itself may be involved in the generation of suppressor function in Con A-activated T cells. The 2H4 antigen on such cells was shown to be comprised of 220,000 and 200,000 m.w. glycoproteins. Thus this study indicates that the 220,000 and 200,000 m.w. structure of the 2H4 molecule may itself play a crucial role in the generation of suppressor signals of Con A-activated cells.
Crushed Ice Ingestion Does Not Improve Female Cycling Time Trial Performance in the Heat.
Zimmermann, Matthew; Landers, Grant Justin; Wallman, Karen Elizabeth
2017-02-01
This study examined the effects of precooling via ice ingestion on female cycling performance in hot, humid conditions. Ten female endurance athletes, mean age (28 ± 6 y), height (167.6 ± 6.5 cm) and body-mass (68.0 ± 11.5 kg) participated in the study. Participants completed an 800 kJ cycle time-trial in hot, humid conditions (34.9 ± 0.3 °C, 49.8 ± 3.5% RH). This was preceded by the consumption of 7 g∙kg -1 of crushed ice (ICE) or water (CON). There was no difference in performance time (CON 3851 ± 449 s; ICE 3767 ± 465 s), oxygen consumption (CON 41.6 ± 7.0 ml∙kg∙min -1 ; ICE 42.4 ± 6.0 ml∙kg∙min -1 ) or respiratory exchange ratio (CON 0.88 ± 0.05; ICE 0.90 ± 0.06) between conditions (p > .05, d < 0.5). Core and skin temperature following the precooling period were lower in ICE (T c 36.4 ± 0.4 °C; T sk 31.6 ± 1.2 °C) compared with CON (T c 37.1 ± 0.4 °C; T sk 32.4 ± 0.7 °C) and remained lower until the 100 kJ mark of the cycle time-trial (p < .05, d > 1.0). Sweat onset occurred earlier in CON (228 ± 113 s) compared with ICE (411 ± 156 s) (p < .05, d = 1.63). Mean thermal sensation (CON 1.8 ± 2.0; ICE 1.2 ± 2.5, p < .05, d = 2.51), perceived exertion (CON 15.3 ± 2.9; ICE 14.9 ± 3.0, p < .05, d = 0.38) and perceived thirst (CON 5.6 ± 2.2; ICE 4.6 ± 2.4, p < .05, d = 0.98) were lower in ICE compared with CON. Crushed ice ingestion did not improve cycling performance in females, although perceptual responses were reduced.
Yan, L; Zhang, Z F; Park, J C; Kim, I H
2012-10-01
A total of 144 pigs ((Landrace×Yorkshire)×Duroc] with an average initial BW of 8.45±0.57 kg were used in a 5-wk growth trial. Pigs were randomly allocated to 4 treatments with 9 replications per pen in a randomized complex block design. Dietary treatments included: i) CON (basal diet), ii) ANT (CON+tylosin 1 g/kg), iii) H1 (CON+H. cordata 1 g/kg) and iv) T1 (CON+T. officinale 1 g/kg). In this study, pigs fed the ANT and T1 treatment had a higher (p<0.05) average daily gain (ADG) and gain:feed (G:F) ratio than those fed CON and H1 treatment. Dietary ANT and T1 treatment led to a higher energy digestibility than the CON group. No difference (p>0.05) was observed on the growth performance and apparent total tract digestibility with H1 supplementation compared with the CON treatment. The inclusion of ANT treatment led to a higher (p<0.05) lymphocyte concentration compared with the CON treatment. Dietary supplementation of herbs did not affect (p>0.05) the blood characteristics (white blood cell (WBC), red blood cell (RBC), IgG, lymphocyte). No difference was observed on (p<0.05) fecal microbial shedding (E. coli and lactobacillus) between ANT and CON groups. Treatments H1 and T1 reduced the fecal E. coli concentration compared with the CON treatment, whereas the fecal lactobacillus concentration was not affected by the herb supplementation (p>0.05). In conclusion, the inclusion of T. officinale (1 g/kg) increased growth performance, feed efficiency, energy digestibility similarly to the antibiotic treatment. Dietary supplementation of T. officinale and H. cordata (1 g/kg) reduced the fecal E. coli concentration in weaning pigs.
Yan, L.; Zhang, Z. F.; Park, J. C.; Kim, I. H.
2012-01-01
A total of 144 pigs ((Landrace×Yorkshire)×Duroc] with an average initial BW of 8.45±0.57 kg were used in a 5-wk growth trial. Pigs were randomly allocated to 4 treatments with 9 replications per pen in a randomized complex block design. Dietary treatments included: i) CON (basal diet), ii) ANT (CON+tylosin 1 g/kg), iii) H1 (CON+H. cordata 1 g/kg) and iv) T1 (CON+T. officinale 1 g/kg). In this study, pigs fed the ANT and T1 treatment had a higher (p<0.05) average daily gain (ADG) and gain:feed (G:F) ratio than those fed CON and H1 treatment. Dietary ANT and T1 treatment led to a higher energy digestibility than the CON group. No difference (p>0.05) was observed on the growth performance and apparent total tract digestibility with H1 supplementation compared with the CON treatment. The inclusion of ANT treatment led to a higher (p<0.05) lymphocyte concentration compared with the CON treatment. Dietary supplementation of herbs did not affect (p>0.05) the blood characteristics (white blood cell (WBC), red blood cell (RBC), IgG, lymphocyte). No difference was observed on (p<0.05) fecal microbial shedding (E. coli and lactobacillus) between ANT and CON groups. Treatments H1 and T1 reduced the fecal E. coli concentration compared with the CON treatment, whereas the fecal lactobacillus concentration was not affected by the herb supplementation (p>0.05). In conclusion, the inclusion of T. officinale (1 g/kg) increased growth performance, feed efficiency, energy digestibility similarly to the antibiotic treatment. Dietary supplementation of T. officinale and H. cordata (1 g/kg) reduced the fecal E. coli concentration in weaning pigs. PMID:25049500
Li, Fan; Ma, Liying; Feng, Yi; Hu, Jing; Ni, Na; Ruan, Yuhua; Shao, Yiming
2017-06-01
HIV-1 transmission in intravenous drug users (IDUs) has been characterized by high genetic multiplicity and suggests a greater challenge for HIV-1 infection blocking. We investigated a total of 749 sequences of full-length gp160 gene obtained by single genome sequencing (SGS) from 22 HIV-1 early infected IDUs in Xinjiang province, northwest China, and generated a transmitted and founder virus (T/F virus) consensus sequence (IDU.CON). The T/F virus was classified as subtype CRF07_BC and predicted to be CCR5-tropic virus. The variable region (V1, V2, and V4 loop) of IDU.CON showed length variation compared with the heterosexual T/F virus consensus sequence (HSX.CON) and homosexual T/F virus consensus sequence (MSM.CON). A total of 26 N-linked glycosylation sites were discovered in the IDU.CON sequence, which is less than that of MSM.CON and HSX.CON. Characterization of T/F virus from IDUs highlights the genetic make-up and complexity of virus near the moment of transmission or in early infection preceding systemic dissemination and is important toward the development of an effective HIV-1 preventive methods, including vaccines.
Yazgi, H; Uyanik, M H; Ayyildiz, A
2009-01-01
This study investigated the colonization of slime-producing coagulase-negative Staphylococcus (CoNS) in 80 patient wards in Turkey (40 vinyl and 40 ceramic tile floors). A total of 480 samples that included 557 CoNS isolates were obtained. Slime production was investigated with the Christensen method and methicillin-susceptibility was tested by the disk-diffusion method. There was a significant difference in the percentage of slime-producing CoNS isolates on vinyl (12.4%) versus ceramic tile flooring (4.4%). From vinyl flooring, the percentage of slime producing methicillin-resistant CoNS (MRCoNS) (8.9%) was significantly higher than for methicillin-sensitive CoNS (MSCoNS) (3.6%), whereas there was no difference from ceramic tile flooring (2.5% MRCoNS versus 1.8% MSCoNS). The most commonly isolated slime-producing CoNS species was S. epidermidis on both types of flooring. It is concluded that vinyl flooring seems to be a more suitable colonization surface for slime-producing CoNS than ceramic tile floors. Further studies are needed to investigate bacterial strains colonized on flooring materials, which are potential pathogens for nosocomial infections.
B cells as accessory cells in a Con A response of a T cell clone.
Takeuchi, M; Kakiuchi, T; Taira, S; Nariuchi, H
1987-12-01
Accessory cell (AC) function of B cells was examined in Con A response of a cloned T cell line, 22-9D, which is Thy 1+,L3T4+,Lyt2-,H-2KbDb+ and I-Ab-.22-9D cells produced IL 2 in the presence of Con A without participation of AC. For the initiation of a proliferative response to Con A, the addition of spleen cells or spleen adherent cells was required. B cells as AC were unable to induce the proliferative response. In the presence of culture supernatant of spleen cells stimulated with Con A (CAS), 22-9D cells showed proliferative response to Con A with B cell AC. The response was inhibited by a relevant monoclonal anti-I-A antibody. Although irradiated spleen cells as AC induced IL 2 receptor expression of 22-9D cells in the presence of Con A, B cells were shown to require the addition of unknown factor(s) in CAS, which was suggested to be different from IL 1, IL 2, IL 3, or IFN-gamma, for the induction of the receptor expression on 22-9D cells.
Games Con Men Play: The Semiosis of Deceptive Interaction.
ERIC Educational Resources Information Center
Hankiss, Agnes
1980-01-01
Analyzes some of the most frequent deceptive interactions as rendered through case histories of male con artists and their victims taken from police records. Discusses the recurrent elements in both the con-games strategies and victims' way of interpreting those strategies. (JMF)
Connected vehicle pilot deployment program phase 1, concept of operations (ConOps) – Tampa (THEA).
DOT National Transportation Integrated Search
2016-02-01
This document describes the Concept of Operations (ConOps) for the Tampa Hillsborough Expressway Authority (THEA) Connected Vehicle (CV) Pilot Deployment. This ConOps describes the current state of operations, establishes the reasons for change, and ...
2012-06-01
in an effort to be more reliable and efficient. However, with the benefits of this new technology comes added risk . This research utilizes a con ...AN APPLICATION OF CON -RESISTANT TRUST TO IMPROVE THE RELIABILITY OF SPECIAL PROTECTION SYSTEMS WITHIN THE SMART GRID THESIS Crystal M. Shipman...Government and is not subject to copyright protection in the United States AFIT/GCO/ENG/12-22 AN APPLICATION OF CON -RESISTANT TRUST TO IMPROVE THE
NASA Technical Reports Server (NTRS)
1994-01-01
In Stennis Space Center's Component Test Facility, piping lines carry rocket propellants and high pressure cryogenic fuels. When the lines are chilled to a pretest temperature of 400 degrees below zero, ordinary piping connectors can leak. Under contract to Stennis, Reflange, Inc. developed the T-Con connector, which included a secondary seal that tolerates severe temperature change. Because of the limited need for the large and expensive T-Con product, Reflange also developed the less costly E-Con, a smaller more compact design with the same technical advantages as the T-Con.
Bueno Vargas, Pilar; Manzano Martín, Manuel; López-Aliaga, Inmaculada; López Pedrosa, José M ª
2016-09-20
Introducción: la gestación y lactancia están relacionadas con pérdidas temporales en la densidad mineral ósea (DMO) materna. Una suplementación con calcio podría resultar beneficiosa para evitar la pérdida de masa ósea del esqueleto materno. Otros nutrientes como los prebióticos han sido identificados como responsables de un incremento en la absorción de minerales, pudiendo condicionar la mineralización ósea.Objetivo: estudiar el efecto de la suplementación de la dieta materna con el prebiótico inulina enriquecida con oligofructosa, durante la gestación y la lactancia sobre el contenido mineral óseo (CMO) y la DMO al final del periodo de lactancia.Métodos: las ratas gestantes fueron alimentadas con dieta estándar (grupo CC), dieta fortificada en calcio (grupo Ca) o enriquecida con el prebiótico inulina enriquecida con oligofructosa (grupo Pre) hasta el final del periodo de lactancia. Posteriormente se evaluó el CMO y DMO por absorciometría de rayos X (DEXA) y el pH del contenido cecal.Resultados:en términos generales, el grupo Pre presenta los mayores valores absolutos de CMO y DMO de entre los tres grupos, siendo en la tibia significativamente diferentes en los grupos CC y Pre frente al grupo Ca. El pH del contenido cecal del grupo Pre es significativamente inferior al de los grupos CC y Ca.Conclusión:la suplementación con inulina enriquecida con oligofructosa, en condiciones nutricionales no deficientes en calcio, durante la gestación y la lactancia, ejerce una protección del esqueleto materno en las ratas y puede ser considerada como una estrategia nutricional para proteger la masa ósea materna en el periodo perinatal.
Nitta, T; Konno-Ejiri, H; Nemoto, K; Okumura, S; Ozawa, A; Nakano, M
1986-09-01
Butanol-extracted water-soluble adjuvant (Bu-WSA) obtained from Bacterionema matruchotii was mitogenic to murine splenic B lymphocytes, but not T lymphocytes. When murine splenic cells were cultured in the presence of Bu-WSA and concanavalin A (Con A) together, [3H]thymidine uptake of the culture cells synergically increased. The mechanism of the synergy of Con A and Bu-WSA and the participation of interleukin (IL) 1 and 2 in the synergy were studied. The proliferation cells in the synergy were Lyt-1+23- lymphocytes. Ia-positive accessory cells were required for the response. When separated cell populations and Marbrook-type culture vessels were used, a mixed cell population of T lymphocytes and B lymphocytes or macrophages (M phi) produced some active factor(s) after co-stimulation by Con A and Bu-WSA, and the factors enhanced DNA synthesis of another Con A-activated T lymphocyte population. Supernatants obtained from the spleen cell cultures or the mixed cell cultures with T lymphocytes and M phi in the presence of Con A and Bu-WSA contained greater amounts of IL-1 and IL-2 than those from cultures containing Con A or Bu-WSA alone. An addition of exogenous IL-1 or IL-2 to spleen cell cultures with Con A resulted in a proliferative response like that obtained through co-stimulation by Con A and Bu-WSA. These results suggest that the synergistic effect of Con A and Bu-WSA on the proliferative response in murine splenic cells is sustained by the enhancement of production of these T-lymphocyte growth factors.
Thrasher, James F; Pérez-Hernández, Rosaura; Arillo-Santillán, Edna; Barrientos-Gutiérrez, Inti
2015-01-01
Resumen Objetivo Evaluar el efecto de las advertencias sanitarias (AS) con pictogramas en las cajetillas de tabaco en adultos fumadores. Material y métodos Cohorte de fumadores con representatividad poblacional de siete ciudades mexi canas, antes (2010) y después (2011) de la implementación de AS con pictogramas (ASP). Para determinar el cambio en las variables sobre el impacto cognitivo y conductual de las advertencias, se estimaron modelos bivariados y ajustados de ecuaciones de estimación generalizada. En el Segundo levantamiento (2011), se estimaron modelos para determiner los factores que se asocian con el reporte de recordar cada advertencia que había entrado al mercado, además de los factores asociados con el autorreporte del impacto de cada advertencia vigente. Resultados Se observaron incrementos importantes de 2010 a 2011 en los conocimientos sobre los riesgos de fumar, los componentes tóxicos del tabaco y el número telefónico para recibir consejos sobre dejar de fumar. La recordación e impacto de las primeras advertencias con pictogramas parecen ser amplios y equitativos a través de la población fumadora. En comparación con 2010, un mayor nivel de ex fumadores entrevistados en 2011 reportaron que las advertencias habían influido mucho en dejar de fumar (RM=2.44, 95% IC 1.27–4.72). Conclusiones Las AS con pictogramas han logrado un impacto importante en el conocimiento y conducta, información relevante para la población y en tomadores de decisiones. PMID:22689162
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-20
... and normal definitions Review proposed TOR changes ConUse Review February 7, 2012 ConUse Review... proposed TOR changes and new or modified Sub-groups' roles and responsibilities Decision to release ConUse...] BILLING CODE 4910-13-P ...
Connected vehicle pilot deployment program phase 1, concept of operations (ConOps) - New York City.
DOT National Transportation Integrated Search
2016-04-08
This document describes the Concept of Operations (ConOps) for the New York City Department of Transportation (NYC) Connected Vehicle Pilot Deployment (CVPD) Project. This ConOps describes the current state of operations, establishes the reasons for ...
Design of protein-responsive micro-sized hydrogels for self-regulating microfluidic systems
NASA Astrophysics Data System (ADS)
Hirayama, Mayu; Tsuruta, Kazuhiro; Kawamura, Akifumi; Ohara, Masayuki; Shoji, Kan; Kawano, Ryuji; Miyata, Takashi
2018-03-01
Diagnosis sensors using micro-total analysis systems (µ-TAS) have been developed for detecting target biomolecules such as proteins and saccharides because they are signal biomolecules for monitoring body conditions and diseases. In this study, biomolecularly stimuli-responsive micro-sized hydrogels that exhibited quick shrinkage in response to lectin concanavalinA (ConA) were prepared in a microchannel by photopolymerization using a fluorescence microscope. In preparing the micro-size hydrogels, glycosyloxyethyl methacrylate (GEMA) as a ligand monomer was copolymerized with a crosslinker in the presence of template ConA in molecular imprinting. The ConA-imprinted micro-hydrogel showed greater shrinkage in response to target ConA than nonimprinted micro-hydrogel. When a buffer solution was switched to an aqueous ConA solution in the Y-shaped microchannel, the flow rates changed quickly because of the responsive shrinkage of the micro-hydrogel prepared in the microchannel. These results suggest that the ConA-imprinted micro-hydrogel acted as a self-regulated microvalve in microfluidic systems.
Salvatore, M; Shu, N; Elofsson, A
2018-01-01
SubCons is a recently developed method that predicts the subcellular localization of a protein. It combines predictions from four predictors using a Random Forest classifier. Here, we present the user-friendly web-interface implementation of SubCons. Starting from a protein sequence, the server rapidly predicts the subcellular localizations of an individual protein. In addition, the server accepts the submission of sets of proteins either by uploading the files or programmatically by using command line WSDL API scripts. This makes SubCons ideal for proteome wide analyses allowing the user to scan a whole proteome in few days. From the web page, it is also possible to download precalculated predictions for several eukaryotic organisms. To evaluate the performance of SubCons we present a benchmark of LocTree3 and SubCons using two recent mass-spectrometry based datasets of mouse and drosophila proteins. The server is available at http://subcons.bioinfo.se/. © 2017 The Protein Society.
Larsen, Malte Nejst; Nielsen, Claus Malta; Helge, Eva Wulff; Madsen, Mads; Manniche, Vibeke; Hansen, Lone; Hansen, Peter Riis; Bangsbo, Jens
2018-01-01
Objectives We investigated whether musculoskeletal fitness of school children aged 8–10 years was affected by frequent intense PE sessions. Design and participants 295 Danish school children aged 8–10 years were cluster randomised to a small-sided ball game group (SSG) (n=96, four schools, five classes), a circuit strength training group (CST) (n=83, four schools, four classes) or a control group (CON, n=116, two schools, five classes). Intervention SSG or CST was performed 3×40 min/week over 10 months. Whole-body dual-energy X-ray absorptiometry (DXA) scans were used to determine areal bone mineral density (aBMD), bone mineral content (BMC) and lean body mass (LBM). Flamingo balance, standing long jump and 20-m sprint tests were used to determine muscular fitness. Results Analysis of baseline-to-10 months change scores showed between-group differences in favour of the interventions in whole-body aBMD (SSG vs CON: 8 mg/cm2, 95% CI 3 to 13; CST vs CON: 7 mg/cm2, 95% CI 2 to 13, p<0.05) and leg BMC (SSG vs CON: 11 g, 95% CI 4 to 18; CST vs CON: 11 g, 95% CI 3 to 18, p<0.05). SSG had higher change scores in leg aBMD compared with CON and CST (SSG vs CON: 19 mg/cm2, 95% CI 11 to 39, p<0.05; SSG vs CST: 12 mg/cm2, 95% CI 3 to 21, p<0.05), and CST had higher change scores in whole-body BMC compared with CON (CST vs CON: 25 g, 95% CI 10 to 39, p<0.05). Both training types resulted in higher change scores in postural balance (SSG vs CON: 2.4 fewer falls/min, 95% CI 0.3 to 4.5, CST vs CON: 3.6 fewer falls/min, 95% CI 1.3 to 5.9, p<0.05) and jump length (SSG vs CON: 10%, 95% CI 5 to 16%; CST vs CON: 9%, 95% CI 3 to 15%, p<0.05). No between-group differences were observed for sprint performance or LBM (p>0.05). Conclusions In conclusion, 3×40 min/week with SSG or CST over a full school year improves bone mineralisation and several aspects of muscular fitness of children aged 8–10 years, suggesting that well-organised intense physical education classes can contribute positively to develop musculoskeletal health in young children. Trial registration number NCT02000492, post results. PMID:27297443
Meeting Report: Breath Biomarkers Networking Sessions at PittCon 2010, Orlando, Florida
The Pittsburgh Conference and Exposition, or "PittCon" (www.pittcon.org/), is one of the largest international conferences for analytical chemistry and instrumentation typically attracting about 25,000 attendees and 1,000 commercial exhibitors. PittCon began in 1950 as a small sp...
Breath Analysis Science at PittCon 2012, Orlando, Florida
Breath analysis science was featured in three organized sessions at this year’s Pittsburgh Conference and Exposition, or ‘PittCon 2012’ (http://www.pittcon.org/). As described in previous meeting reports, PittCon is one of the largest international conferences for analytical chem...
Code of Federal Regulations, 2013 CFR
2013-10-01
... REGULATION SYSTEM Career Development, Contracting Authority, and Responsibilities 301.608 Training... Arrangements). • CON 110 (Mission Support Planning). Purchase cardholders and Approving Officials Yearly... appropriations law. • CON 100 (Shaping Smart Business Arrangements). • CON 110 (Mission Support Planning). Agency...
Code of Federal Regulations, 2014 CFR
2014-10-01
... REGULATION SYSTEM Career Development, Contracting Authority, and Responsibilities 301.608 Training... Arrangements). • CON 110 (Mission Support Planning). Purchase cardholders and Approving Officials Yearly... appropriations law. • CON 100 (Shaping Smart Business Arrangements). • CON 110 (Mission Support Planning). Agency...
Akbar, Haji; Batistel, Fernanda; Drackley, James K.; Loor, Juan J.
2015-01-01
In rodents, fibroblast growth factor 21 (FGF21) has emerged as a key metabolic regulator produced by liver. To gather preliminary data on the potential importance of FGF1, co-regulated genes, and upstream metabolic genes, we examined the hepatic mRNA expression in response to nutrition and inflammation in dairy cows. In experiment 1, induction of ketosis through feed restriction on d 5 postpartum upregulated FGF21, its co-receptor KLB, and PPARA but only elicited a numerical increase in serum FGF21 concentration. In experiment 2, cows in control (CON) or receiving 50 g/d of L-carnitine (C50) from -14 through 21 d had increased FGF21, PPARA, and NFIL3 on d 10 compared with d 2 postpartum. In contrast, compared with CON and C50, 100 g/d L-carnitine (C100) resulted in lower FGF21, KLB, ANGPTL4, and ARNTL expression on d 10. In experiment 3, cows were fed during the dry period either a higher-energy (OVE; 1.62 Mcal/kg DM) or lower-energy (CON; 1.34 Mcal/kg DM) diet and received 0 (OVE:N, CON:N) or 200 μg of LPS (OVE:Y, CON:Y) into the mammary gland at d 7 postpartum. For FGF21 mRNA expression in CON, the LPS challenge (CON:Y) prevented a decrease in expression between d 7 and 14 postpartum such that cows in CON:N had a 4-fold lower expression on d 14 compared with d 7. The inflammatory stimulus induced by LPS in CON:Y resulted in upregulation of PPARA on d 14 to a similar level as cows in OVE:N. In OVE:Y, expression of PPARA was lower than CON:N on d 7 and remained unchanged on d 14. On d 7, LPS led to a 4-fold greater serum FGF21 only in OVE but not in CON cows. In fact, OVE:Y reached the same serum FGF21 concentration as CON:N, suggesting a carryover effect of dietary energy level on signaling mechanisms within liver. Overall, results indicate that nutrition, ketosis, and inflammation during the peripartal period can alter hepatic FGF21, co-regulated genes, and upstream metabolic genes to various extents. The functional outcome of these changes merits further study, and in particular the mechanisms regulating transcription in response to changes in energy balance and feed intake. PMID:26451842
Akbar, Haji; Batistel, Fernanda; Drackley, James K; Loor, Juan J
2015-01-01
In rodents, fibroblast growth factor 21 (FGF21) has emerged as a key metabolic regulator produced by liver. To gather preliminary data on the potential importance of FGF1, co-regulated genes, and upstream metabolic genes, we examined the hepatic mRNA expression in response to nutrition and inflammation in dairy cows. In experiment 1, induction of ketosis through feed restriction on d 5 postpartum upregulated FGF21, its co-receptor KLB, and PPARA but only elicited a numerical increase in serum FGF21 concentration. In experiment 2, cows in control (CON) or receiving 50 g/d of L-carnitine (C50) from -14 through 21 d had increased FGF21, PPARA, and NFIL3 on d 10 compared with d 2 postpartum. In contrast, compared with CON and C50, 100 g/d L-carnitine (C100) resulted in lower FGF21, KLB, ANGPTL4, and ARNTL expression on d 10. In experiment 3, cows were fed during the dry period either a higher-energy (OVE; 1.62 Mcal/kg DM) or lower-energy (CON; 1.34 Mcal/kg DM) diet and received 0 (OVE:N, CON:N) or 200 μg of LPS (OVE:Y, CON:Y) into the mammary gland at d 7 postpartum. For FGF21 mRNA expression in CON, the LPS challenge (CON:Y) prevented a decrease in expression between d 7 and 14 postpartum such that cows in CON:N had a 4-fold lower expression on d 14 compared with d 7. The inflammatory stimulus induced by LPS in CON:Y resulted in upregulation of PPARA on d 14 to a similar level as cows in OVE:N. In OVE:Y, expression of PPARA was lower than CON:N on d 7 and remained unchanged on d 14. On d 7, LPS led to a 4-fold greater serum FGF21 only in OVE but not in CON cows. In fact, OVE:Y reached the same serum FGF21 concentration as CON:N, suggesting a carryover effect of dietary energy level on signaling mechanisms within liver. Overall, results indicate that nutrition, ketosis, and inflammation during the peripartal period can alter hepatic FGF21, co-regulated genes, and upstream metabolic genes to various extents. The functional outcome of these changes merits further study, and in particular the mechanisms regulating transcription in response to changes in energy balance and feed intake.
Fusion and reaction mechanism evolution in 24Mg+12C at intermediate energies
NASA Astrophysics Data System (ADS)
Samri, M.; Grenier, F.; Ball, G. C.; Beaulieu, L.; Gingras, L.; Horn, D.; Larochelle, Y.; Moustabchir, R.; Roy, R.; St-Pierre, C.; Theriault, D.
2002-06-01
The formation and deexcitation of fusionlike events selected in events with a total charge equal or greater than 16 in 24Mg+12C system has been investigated at 25, 35, and 45 MeV/nucleon with a large multidetector array. Central single-source events are selected by use of the statistical discriminant analysis method applied to a set of 26 global variables. The fusion cross section has been extracted for the three bombarding energies and compared to other experimental data and to theoretical predictions. The total multiplicity is found to first increase to a maximum value and then decrease with increasing beam energy. It is shown that this behavior is connected to the opening of multifragmentation channels at 45 MeV/nucleon and the disappearance of channels with only light charged particles.
Ibáñez Sanz, L; Borruel Nacenta, S; Cano Alonso, R; Díez Martínez, P; Navallas Irujo, M
2015-01-01
Gastrointestinal volvuli cause processes that manifest as acute abdomen. Volvuli are important not because they are common, but rather because their possible complications can be severe. All types of volvuli share a common pathophysiology, which consists of intestinal obstruction in a closed loop that results in ischemia. The clinical manifestations are nonspecific, so radiologists play a very important role in the early identification of the most common signs of torsion. These include the "bird's beak sign", the "whirlpool sign", and signs of potentially reversible or irreversible ischemia. The treatment of choice in most cases is surgery, either to correct the torsion and save the organ or to resect it if it is necrotic. Copyright © 2012 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
A brief review of chronic obstructive pulmonary disease.
Hogg, James C
2012-01-01
A recent study, based on a combination of multidetector computed tomography scanning of an intact specimen with microcomputed tomography and histological analysis of lung tissue samples, reported that the number of terminal bronchioles were reduced from approximately 44,500/lung pair in control (donor) lungs to approximately 4800/lung pair in lungs donated by individuals with very severe (Global initiative for chronic Obstructive Lung Disease stage 4) chronic obstructive pulmonary disease (COPD) treated by lung transplantation. The present short review discusses the hypothesis that a rapid rate of terminal bronchiolar destruction causes the rapid decline in lung function leading to advanced COPD. With respect to why the terminal bronchioles are targeted for destruction, the postulated mechanisms of this destruction and the possibility that new treatments are able to either prevent or reverse the underlying cause of airway obstruction in COPD are addressed.
Robust extraction of the aorta and pulmonary artery from 3D MDCT image data
NASA Astrophysics Data System (ADS)
Taeprasartsit, Pinyo; Higgins, William E.
2010-03-01
Accurate definition of the aorta and pulmonary artery from three-dimensional (3D) multi-detector CT (MDCT) images is important for pulmonary applications. This work presents robust methods for defining the aorta and pulmonary artery in the central chest. The methods work on both contrast enhanced and no-contrast 3D MDCT image data. The automatic methods use a common approach employing model fitting and selection and adaptive refinement. During the occasional event that more precise vascular extraction is desired or the method fails, we also have an alternate semi-automatic fail-safe method. The semi-automatic method extracts the vasculature by extending the medial axes into a user-guided direction. A ground-truth study over a series of 40 human 3D MDCT images demonstrates the efficacy, accuracy, robustness, and efficiency of the methods.
Gunshot injuries in the neck area: ballistics elements and forensic issues.
Pinto, Antonio; Brunese, Luca; Scaglione, Mariano; Scuderi, Maria Giuseppina; Romano, Luigia
2009-06-01
The neck is an interesting structure as far as penetrating trauma is concerned because of the multiple vital structures that are concentrated in a small anatomic area. Gunshot wounding is an interaction between the penetrating projectile, the anatomy of the wounded subject, and the chance occurrences that determine the exact missile path. The mass and velocity of the projectile establish the upper limit of possible tissue damage. Management of gunshot neck injuries depends on a clear understanding of the anatomy of the neck. The radiologist can contribute substantially to the successful treatment of the patient with a gunshot wound. Important analysis includes the assessment of the missile path in emergency conditions by using plain film and multidetector row computed tomography. The radiologist further evaluates the extent of wounding by determining missile fragmentation and secondary missile paths.
Electrocardiographically gated 16-section CT of the thorax: cardiac motion suppression.
Hofmann, Lars K; Zou, Kelly H; Costello, Philip; Schoepf, U Joseph
2004-12-01
Thirty patients underwent 16-section multi-detector row computed tomographic (CT) angiography of the thorax with retrospective electrocardiographic gating. Institutional review board approval was obtained for retrospective analysis of CT scan data and records; patient informed consent was not required. Images reconstructed at six different time points (0%, 20%, 40%, 50%, 60%, 80%) within the R-R interval on the electrocardiogram were analyzed by two radiologists for diagnostic quality, to identify suitable reconstruction intervals for optimal suppression of cardiac motion. Five regions of interest (left coronary artery, aortic root, ascending and descending aorta, pulmonary arteries) were evaluated. Best image quality was achieved by referencing image reconstruction to middiastole (50%-60%) for the left coronary artery, aortic root, and ascending aorta. The pulmonary arteries are best displayed during mid- to late diastole (80%). (c) RSNA, 2004
Vascular liver anatomy and main variants: what the radiologist must know.
Seco, M; Donato, P; Costa, J; Bernardes, A; Caseiro-Alves, F
2010-01-01
Advances in surgical techniques are extremely demanding regarding the accuracy and level of detail expected for display of the vascular anatomy of the liver. Precise knowledge of the arterial, portal and hepatic vein territories are mandatory whenever a liver intervention is planned. Sectional anatomy can now be routinely performed on multidetector computed tomography (MDCT) with volumetric data and isotropic voxel display, by means of sub-millimetric slice thickness acquisition. The relevant vascular information can thus be gathered, reviewed and post-processed with unprecedented clarity, obviating the need for digital subtraction angiography. The scope of the present paper is to review the normal vascular liver anatomy, its most relevant variants including additional sources of vascular inflow. Apart from providing the surgeon with a detailed vascular and parenchymal roadmap knowledge of imaging findings may avoid potential confusion with pathologic processes.
NASA Astrophysics Data System (ADS)
Mei, Kai; Kopp, Felix K.; Fehringer, Andreas; Pfeiffer, Franz; Rummeny, Ernst J.; Kirschke, Jan S.; Noël, Peter B.; Baum, Thomas
2017-03-01
The trabecular bone microstructure is a key to the early diagnosis and advanced therapy monitoring of osteoporosis. Regularly measuring bone microstructure with conventional multi-detector computer tomography (MDCT) would expose patients with a relatively high radiation dose. One possible solution to reduce exposure to patients is sampling fewer projection angles. This approach can be supported by advanced reconstruction algorithms, with their ability to achieve better image quality under reduced projection angles or high levels of noise. In this work, we investigated the performance of iterative reconstruction from sparse sampled projection data on trabecular bone microstructure in in-vivo MDCT scans of human spines. The computed MDCT images were evaluated by calculating bone microstructure parameters. We demonstrated that bone microstructure parameters were still computationally distinguishable when half or less of the radiation dose was employed.
That liver lesion on MDCT in the oncology patient: is it important?
Thakrar, Kiran H.; Wenzke, Daniel R.; Newmark, Geraldine M.; Mehta, Uday K.; Berlin, Jonathan W.
2012-01-01
Abstract Multidetector-row computed tomography (MDCT) has become the primary imaging test for the staging and follow-up of most malignancies that originate outside of the central nervous system. Technical advances in this imaging technique have led to significant improvement in the detection of metastatic disease to the liver. An unintended by-product of this improving diagnostic acumen is the discovery of incidental hepatic lesions in oncology patients that in the past remained undetected. These ubiquitous, incidentally identified hepatic lesions have created a management dilemma for both clinicians and radiologists: are these lesions benign or do they represent metastases? Naturally, the answer to this question has profound prognostic and therapeutic implications. In this review, guidelines concerning the diagnosis and management of some of the more common hepatic incidental lesions detected in patients with extrahepatic malignancies are presented. PMID:23023318
Abundancias químicas de ψ Octantis
NASA Astrophysics Data System (ADS)
Medina, M. C.; Pintado, O. I.
Se determinan las abundancias químicas de ψ Oct usando espectros obtenidos con EBASIM en CASLEO. Los valores iniciales de temperatura efectiva y gravedad superficial se calculan con la fotometría uvbyβ. Esta estrella fue estudiada por Pintado y Adelman (1996) usando espectros REOSC y Adelman y otros (1993), este último basado en espectros echelle obtenidos con el Telescopio Anglo Australiano. Comparamos nuestros resultados con los de los trabajos anteriormente mencionados, pudiéndose realizar una evaluación de la calidad de los espectros EBASIM.
Sakane, T; Honda, M; Taniguchi, Y; Kotani, H
1981-08-01
Very few normal human peripheral blood T cells are capable of binding autologous erythrocytes to form rosettes, whereas in the T cell population activated by concanavalin A (Con A) the autorosette levels are markedly enhanced. Fractionation of the Con A-activated T cells with autologous erythrocytes into autorosetting and nonrosetting cells demonstrates that suppressor, but not helper, activity resides in the autorosetting population, whereas the reverse is true of the nonrosetting population. Both these activities are found to be Con A dependent. The Con A-induced human suppressor cells can be identified and separated from the Con A-induced human helper cells by the autorosette technique. Studies on the surface properties of autorosetting and nonrosetting T cells indicate that there is little correlation between the activated suppressor and helper T cell subsets defined by autorosette technique and either those defined by monoclonal antibodies (which are able to distinguish these subsets in the resting but not activated T cells) or those defined by Fc receptors. Since the autorosetting T cell population (which acts as suppressor cells) bears receptors for peanut agglutinin, the nature of Con A-induced human suppressor cells appears to be analogous to that of Con A-induced murine suppressor cells.
Optic neuropathy in thyroid eye disease: results of the balanced decompression technique.
Baril, Catherine; Pouliot, Denis; Molgat, Yvonne
2014-04-01
To determine the efficacy of combined endoscopic medial and external lateral orbital decompression for the treatment of compressive optic neuropathy (CON) in thyroid eye disease (TED). A retrospective review of all patients undergoing combined surgical orbital decompression for CON between 2000 and 2010 was conducted. Fifty-nine eyes of 34 patients undergoing combined surgical orbital decompression for CON. Clinical outcome measures included visual acuity, Hardy-Rand-Rittler (HRR) colour plate testing, relative afferent pupillary defect, intraocular pressure measurement, and Hertel exophthalmometry. A CON score was calculated preoperatively and postoperatively based on the visual acuity and the missed HRR plates. A higher CON score correlates with more severe visual dysfunction. All patients had improvement of their optic neuropathy after surgical decompression. CON score was calculated for 54 eyes and decreased significantly from a mean of 13.2 ± 10.35 preoperatively to a mean of 8.51 ± 10.24 postoperatively (p < 0.0001). Optic neuropathy was completely resolved in 93.22% (55/59 eyes). Eighteen of 34 patients (52.94%) experienced development of new-onset postoperative strabismus that required subsequent surgical intervention. Endoscopic medial combined with external lateral orbital decompression is an effective technique for the treatment of TED-associated CON. © 2013 Canadian Ophthalmological Society Published by Canadian Ophthalmological Society All rights reserved.
Christensen, Kurt D.; Roberts, J. Scott; Uhlmann, Wendy R.; Green, Robert C.
2011-01-01
Purpose Perceptions about the pros and cons of genetic susceptibility testing are among the best predictors of test utilization. How actual testing changes such perceptions has yet to be examined. Methods In a clinical trial, first-degree relatives of patients with Alzheimer disease received genetic risk assessments for Alzheimer disease including APOE disclosure. Participants rated 11 possible benefits associated with genetic testing (pros) and 10 risks or limitations (cons) before genetic risk disclosure and again 12 months afterward. Results Pros were rated higher than cons at baseline (3.53 vs. 1.83, P < 0.001) and at 12 months after risk disclosure (3.33 vs. 1.88, P < 0.001). Ratings of pros decreased during the 12-month period (3.33 vs. 3.53, P < 0.001). Ratings of cons did not change (1.88 vs. 1.83, P = 0.199) except for a three-item discrimination subscale which increased (2.07 vs. 1.92, P = 0.012). Among specific pros and cons, three items related to prevention and treatment changed the most. Conclusion The process of APOE genetic risk assessment for Alzheimer disease sensitizes some to its limitations and the risks of discrimination; however, 1-year after disclosure, test recipients still consider the pros to strongly outweigh the cons. PMID:21270636
Altered thermoregulatory responses in heart failure patients exercising in the heat.
Balmain, Bryce N; Jay, Ollie; Sabapathy, Surendran; Royston, Danielle; Stewart, Glenn M; Jayasinghe, Rohan; Morris, Norman R
2016-11-01
Heart failure (HF) patients appear to exhibit impaired thermoregulatory capacity during passive heating, as evidenced by diminished vascular conductance. Although some preliminary studies have described the thermoregulatory response to passive heating in HF, responses during exercise in the heat remain to be described. Therefore, the aim of this study was to compare thermoregulatory responses in HF and controls (CON) during exercise in the heat. Ten HF (NYHA classes I-II) and eight CON were included. Core temperature (T c ), skin temperature (T sk ), and cutaneous vascular conductance (CVC) were assessed at rest and during 1 h of exercise at 60% of maximal oxygen uptake. Metabolic heat production (H prod ) and the evaporative requirements for heat balance (E req ) were also calculated. Whole-body sweat rate was determined from pre-post nude body mass corrected for fluid intake. While H prod (HF: 3.9 ± 0.9; CON: 6.4 ± 1.5 W/kg) and E req (HF: 3.3 ± 0.9; CON: 5.6 ± 1.4 W/kg) were lower (P < 0.01) for HF compared to CON, both groups demonstrated a similar rise in T c (HF: 0.9 ± 0.4; CON: 1.0 ± 0.3°C). Despite this similar rise in T c , T sk (HF: 1.6 ± 0.7; CON: 2.7 ± 1.2°C), and the elevation in CVC (HF: 1.4 ± 1.0; CON: 3.0 ± 1.2 au/mmHg) was lower (P < 0.05) in HF compared to CON Additionally, whole-body sweat rate (HF: 0.36 ± 0.15; CON: 0.81 ± 0.39 L/h) was lower (P = 0.02) in HF compared to CON Patients with HF appear to be limited in their ability to manage a thermal load and distribute heat content to the body surface (i.e., skin), secondary to impaired circulation to the periphery. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
Becknell, Brian; Mohamed, Ahmad Z; Li, Birong; Wilhide, Michael E; Ingraham, Susan E
2015-01-01
Urinary stasis is a risk factor for recurrent urinary tract infection (UTI). Homozygous mutant Megabladder (Mgb-/-) mice exhibit incomplete bladder emptying as a consequence of congenital detrusor aplasia. We hypothesize that this predisposes Mgb-/- mice to spontaneous and experimental UTI. Mgb-/-, Mgb+/-, and wild-type female mice underwent serial ultrasound and urine cultures at 4, 6, and 8 weeks to detect spontaneous UTI. Urine bacterial isolates were analyzed by Gram stain and speciated. Bladder stones were analyzed by x-ray diffractometry. Bladders and kidneys were subject to histologic analysis. The pathogenicity of coagulase-negative Staphylococcus (CONS) isolated from Mgb-/- urine was tested by transurethral administration to culture-negative Mgb-/- or wild-type animals. The contribution of urinary stasis to CONS susceptibility was evaluated by cutaneous vesicostomy in Mgb-/- mice. Mgb-/- mice develop spontaneous bacteriuria (42%) and struvite bladder stones (31%) by 8 weeks, findings absent in Mgb+/- and wild-type controls. CONS was cultured as a solitary isolate from Mgb-/- bladder stones. Bladders and kidneys from mice with struvite stones exhibit mucosal injury, inflammation, and fibrosis. These pathologic features of cystitis and pyelonephritis are replicated by transurethral inoculation of CONS in culture-negative Mgb-/- females, whereas wild-type animals are less susceptible to CONS colonization and organ injury. Cutaneous vesicostomy prior to CONS inoculation significantly reduces the quantity of CONS recovered from Mgb-/- urine, bladders, and kidneys. CONS is an opportunistic uropathogen in the setting of urinary stasis, leading to enhanced UTI incidence and severity in Mgb-/- mice.
Becknell, Brian; Mohamed, Ahmad Z.; Li, Birong; Wilhide, Michael E.; Ingraham, Susan E.
2015-01-01
Purpose Urinary stasis is a risk factor for recurrent urinary tract infection (UTI). Homozygous mutant Megabladder (Mgb-/-) mice exhibit incomplete bladder emptying as a consequence of congenital detrusor aplasia. We hypothesize that this predisposes Mgb-/- mice to spontaneous and experimental UTI. Methods Mgb-/-, Mgb+/-, and wild-type female mice underwent serial ultrasound and urine cultures at 4, 6, and 8 weeks to detect spontaneous UTI. Urine bacterial isolates were analyzed by Gram stain and speciated. Bladder stones were analyzed by x-ray diffractometry. Bladders and kidneys were subject to histologic analysis. The pathogenicity of coagulase-negative Staphylococcus (CONS) isolated from Mgb-/- urine was tested by transurethral administration to culture-negative Mgb-/- or wild-type animals. The contribution of urinary stasis to CONS susceptibility was evaluated by cutaneous vesicostomy in Mgb-/- mice. Results Mgb-/- mice develop spontaneous bacteriuria (42%) and struvite bladder stones (31%) by 8 weeks, findings absent in Mgb+/- and wild-type controls. CONS was cultured as a solitary isolate from Mgb-/- bladder stones. Bladders and kidneys from mice with struvite stones exhibit mucosal injury, inflammation, and fibrosis. These pathologic features of cystitis and pyelonephritis are replicated by transurethral inoculation of CONS in culture-negative Mgb-/- females, whereas wild-type animals are less susceptible to CONS colonization and organ injury. Cutaneous vesicostomy prior to CONS inoculation significantly reduces the quantity of CONS recovered from Mgb-/- urine, bladders, and kidneys. Conclusions CONS is an opportunistic uropathogen in the setting of urinary stasis, leading to enhanced UTI incidence and severity in Mgb-/- mice. PMID:26401845
Chacko, Mariam R; von Sternberg, Kirk; Velasquez, Mary M; Wiemann, Constance M; Smith, Peggy B; DiClemente, Ralph
2008-08-01
To identify young women's pros and cons (decisional balance) to seeking chlamydia (CT) and gonorrhea (NGC) screening. Prospective, cross sectional study Community-based reproductive health clinic 192 young women (66% African American; mean age 18.9 years). Content analysis of responses obtained during a decisional balance exercise (pros and cons) promoting CT and NGC screening was conducted. Thematic categories were developed through a coding process, and each response was assigned to one thematic category. The frequency of pros and cons responses for each category and the frequency of participants endorsing each category were calculated. Ten thematic categories in relation to pros and cons of seeking CT and NGC screening were: being healthy; awareness of the body; systemic factors around the clinic visit and testing procedures; benefits and aversions around treatment; partner trust issues; confidentiality; prevention of long term adverse effects, protection of the body; concern for others; fear of results/aversion to testing; and logistical barriers. The three most often cited pros were awareness of the body, being healthy and treatment issues; and the three most often cited cons were logistical barriers (time/transportation), fear/aversion to testing, and systemic factors. A variety of pros and cons to seeking CT and NGC screening were identified at a community-based clinic. Providers in clinical settings can utilize this information when encouraging patients to seek regular STI screening by elucidating and emphasizing those pros and cons that have the most influence on a young woman's decision-making to seek screening.
Chacko, Mariam R.; von Sternberg, Kirk; Velasquez, Mary M.; Wiemann, Constance M.; Smith, Peggy B.; DiClemente, Ralph
2008-01-01
Study Objective To identify young women’s pros and cons (decisional balance) to seeking chlamydia (CT) and gonorrhea (NGC) screening. Design Prospective, cross sectional study Setting Community-based reproductive health clinic Participants 192 young women (66% African American; mean age 18.9 years). Main Outcome Measure(s) Content analysis of responses obtained during a decisional balance exercise (pros and cons) promoting CT and NGC screening was conducted. Thematic categories were developed through a coding process, and each response was assigned to one thematic category. The frequency of pros and cons responses for each category and the frequency of participants endorsing each category were calculated. Results Ten thematic categories in relation to pros and cons of seeking CT and NGC screening were: being healthy; awareness of knowing the body; systemic factors around the clinic visit and testing procedures; benefits and aversions around treatment; partner relationship issues; confidentiality; prevention of long term adverse effects, protection of the body; concern for others; fear of results/aversion to testing; and logistical barriers. The three most often cited pros were awareness, healthy and treatment issues; and the three most often cited cons were logistical barriers (time/transportation), fear/aversion to testing, and systemic issues. Conclusions A variety of pros and cons to seeking CT and NGC screening were identified at a community-based clinic. Providers in clinical settings can utilize this information when encouraging patients to seek regular STI screening by elucidating and emphasizing those pros and cons that have the most influence on a young woman’s decision-making to seek screening. PMID:18656072
Lin, Shao-Yu; Chooi, Yit-Heng; Solomon, Peter S
2018-05-03
To investigate effector gene regulation in the wheat pathogenic fungus Parastagonospora nodorum, the promoter and expression of Tox3 was characterised through a series of complementary approaches. Promoter deletion and DNase I footprinting experiments identified a 25 bp region in the Tox3 promoter as being required for transcription. Subsequent yeast one-hybrid analysis using the DNA sequence as bait identified that interacting partner as the C2H2 zinc finger transcription factor PnCon7, a putative master regulator of pathogenesis. Silencing of PnCon7 resulted in the down-regulation of Tox3 demonstrating that the transcription factor has a positive regulatory role on gene expression. Analysis of Tox3 expression in the PnCon7 silenced strains revealed a strong correlation with PnCon7 transcript levels, supportive of a direct regulatory role. Subsequent pathogenicity assays using PnCon7-silenced isolates revealed that the transcription factor was required for Tox3-mediated disease. The expression of two other necrotrophic effectors (ToxA and Tox1) was also affected but in a non-dose dependent manner suggesting that the regulatory role of PnCon7 on these genes was indirect. Collectively, these data have advanced our fundamental understanding of the Con7 master regulator of pathogenesis by demonstrating its positive regulatory role on the Tox3 effector in P. nodorum through direct interaction. This article is protected by copyright. All rights reserved. © 2018 John Wiley & Sons Ltd.
Trazando la materia oscura con cúmulos globulares
NASA Astrophysics Data System (ADS)
Forte, J. C.
Se describe la estrategia adoptada para mapear la distribución de materia oscura y bariónica en galaxias elípticas cuyos cúmulos globulares están siendo observados con los telescopios VLT y Gemini. Se ejemplifican los resultados con los datos obtenidos en el cúmulo de Fornax.
Estudio de eventos dinámicos en ondas milimétricas
NASA Astrophysics Data System (ADS)
Cristiani, G.; Martínez, G.; Raulin, J. P.; Giménez de Castro, G.; Rovira, M.
El estudio de la actividad solar con el telescopio para ondas submilimétricas (SST), nos permite, por vez primera, trabajar con una resolución temporal de milisegundos. Este hecho ha permitido observar emisión nunca antes comprobada, pulsos o flashes extremadamente rápidos provenientes de las regiones activas, los cuales parecen preanunciar fulguraciones en dichas regiones. Se muestra, como ejemplo, una fulguración observada con el telescopio HASTA en Hα, y los pulsos rápidos que la preceden observados con el SST. Para cuantificar la influencia de la atmósfera terrestre en los datos registrados, se está estudiando la variabilidad temporal de las opacidades a las frecuecias de trabajo (212 y 405 Ghz), es decir los rangos de tiempo para los cuales la opacidad puede variar apreciablemente. Con este fin se calcula la eficiencia de cada canal multiplicada por la temperatura del Sol a estas frecuencias (estas son conocidas con una incerteza del 20 %). Se muestran los resultados obtenidos para cada canal, en donde se grafica este producto como función de la opacidad.
Mutants of Neurospora crassa that alter gene expression and conidia development.
Madi, L; Ebbole, D J; White, B T; Yanofsky, C
1994-01-01
Several genes have been identified that are highly expressed during conidiation. Inactivation of these genes has no observable phenotypic effect. Transcripts of two such genes, con-6 and con-10, are normally absent from vegetative mycelia. To identify regulatory genes that affect con-6 and/or con-10 expression, strains were prepared in which the regulatory regions for these genes were fused to a gene conferring hygromycin resistance. Mutants were then selected that were resistant to the drug during mycelial growth. Mutations in several of the isolates had trans effects; they activated transcription of the corresponding intact gene and, in most isolates, one or more of the other con genes. Most interestingly, resistant mutants were obtained that were defective at different stages of conidiation. One mutant conidiated under conditions that do not permit conidiation in wild type. Images PMID:8016143
La salud en personas con discapacidad intelectual en España: estudio europeo POMONA-II
Martínez-Leal, Rafael; Salvador-Carulla, Luis; Gutiérrez-Colosía, Mencía Ruiz; Nadal, Margarida; Novell-Alsina, Ramón; Martorell, Almudena; González-Gordón, Rodrigo G.; Mérida-Gutiérrez, M. Reyes; Ángel, Silvia; Milagrosa-Tejonero, Luisa; Rodríguez, Alicia; García-Gutiérrez, Juan C.; Pérez-Vicente, Amado; García-Ibáñez, José; Aguilera-Inés, Francisco
2011-01-01
Introducción Estudios internacionales demuestran que existe un patrón diferenciado de salud y una disparidad en la atención sanitaria entre personas con discapacidad intelectual (DI) y población general. Objetivo Obtener datos sobre el estado de salud de las personas con DI y compararlos con datos de población general. Pacientes y métodos Se utilizó el conjunto de indicadores de salud P15 en una muestra de 111 sujetos con DI. Los datos de salud encontrados se compararon según el tipo de residencia de los sujetos y se utilizó la Encuesta Nacional de Salud 2006 para comparar estos datos con los de la población general. Resultados La muestra con DI presentó 25 veces más casos de epilepsia y el doble de obesidad. Un 20% presentó dolor bucal, y existió una alta presencia de problemas sensoriales, de movilidad y psicosis. Sin embargo, encontramos una baja presencia de patologías como la diabetes, la hipertensión, la osteoartritis y la osteoporosis. También presentaron una menor participación en programas de prevención y promoción de la salud, un mayor número de ingresos hospitalarios y un uso menor de los servicios de urgencia. Conclusiones El patrón de salud de las personas con DI difiere del de la población general, y éstas realizan un uso distinto de los servicios sanitarios. Es importante el desarrollo de programas de promoción de salud y de formación profesional específicamente diseñados para la atención de personas con DI, así como la implementación de encuestas de salud que incluyan datos sobre esta población. PMID:21948011
Kim, Duwoon; Lee, Hee-Min; Oh, Kyung-Seo; Ki, Ah Young; Protzman, Rachael A; Kim, Dongkyun; Choi, Jong-Soon; Kim, Min Ji; Kim, Sung Hyun; Vaidya, Bipin; Lee, Seung Jae; Kwon, Joseph
2017-06-01
Rapid methods for the detection and clinical treatment of human norovirus (HuNoV) are needed to control foodborne disease outbreaks, but reliable techniques that are fast and sensitive enough to detect small amounts of HuNoV in food and aquatic environments are not yet available. We explore the interactions between HuNoV and concanavalin A (Con A), which could facilitate the development of a sensitive detection tool for HuNoV. Biophysical studies including hydrogen/deuterium exchange (HDX) mass spectrometry and surface plasmon resonance (SPR) revealed that when the metal coordinated region of Con A, which spans Asp16 to His24, is converted to nine alanine residues (mCon A MCR ), the affinity for HuNoV (GII.4) diminishes, demonstrating that this Ca 2+ and Mn 2+ coordinated region is responsible for the observed virus-protein interaction. The mutated carbohydrate binding region of Con A (mCon A CBR ) does not affect binding affinity significantly, indicating that MCR of Con A is a major region of interaction to HuNoV (GII.4). The results further contribute to the development of a HuNoV concentration tool, Con A-immobilized polyacrylate beads (Con A-PAB), for rapid detection of genotypes from genogroups I and II (GI and GII). This method offers many advantages over currently available methods, including a short concentration time. HuNov (GI and GII) can be detected in just 15 min with 90% recovery through Con A-PAB application. In addition, this method can be used over a wide range of pH values (pH 3.0 - 10.0). Overall, this rapid and sensitive detection of HuNoV (GI and GII) will aid in the prevention of virus transmission pathways, and the method developed here may have applicability for other foodborne viral infections. Copyright © 2017 Elsevier Ltd. All rights reserved.
Observación espectroscópica de NGC 2442
NASA Astrophysics Data System (ADS)
Agüero, E.; Bajaja, E.; Paolantonio, S.
La galaxia NGC 2442 (SAB(s)bc pec) fue observada con el telescopio de 2,15 m y el espectrógrafo REOSC del CASLEO utilizando el detector CCD Tektronix de 1024 × 1024 pixels de 24 μ m (0,26"). Las exposiciones fueron realizadas con la ranura de 3,3'' × 348'', en el plano focal, ubicadas en seis posiciones, cinco a 40o de áng. de pos. y una a 79o. La mayor parte de las exposiciones se efectuó con la red de 1200 líneas mm-1, a un ángulo de 25,53o cubriendo el rango de λλ 6200 a 6900 con dispersión de 32Å mm-1 y resolución de 2,5 Å. Las relaciones entre las intensidades de las líneas de emisión en el núcleo de NGC 2442 indican que es un LINER lo cual es compatible con la sugerencia de Shobrook de que se trataría de una galaxia Seyfert u otro tipo de galaxia activa. La temperatura y densidad electrónicas nucleares son Te ~14.000 K y Ne ~ 530 cm-3, respectivamente. Una región a 87'' al NE en cambio, donde las intensidades son también altas, presenta características espectrales típicas de una Región HII con Te ~6500 K y Ne ~10 cm-3. La correlación de las intensidades con el CO en 115 GHz y con el continuo en 843 MHz y de las velocidades ópticas con las del CO, a lo largo del eje mayor, son muy buenas. La mayor resolución angular de las observaciones, sin embargo, permite apreciar la existencia de dos componentes de velocidad en el núcleo que pueden corresponder a un anillo en rotación o a un fenómeno de expansión.
Nakashima, Hiroyuki; Kinoshita, Manabu; Nakashima, Masahiro; Habu, Yoshiko; Shono, Satoshi; Uchida, Takefumi; Shinomiya, Nariyoshi; Seki, Shuhji
2008-12-01
Although concanavalin A (Con-A)-induced experimental hepatitis is thought to be induced by activated T cells, natural killer T (NKT) cells, and cytokines, precise mechanisms are still unknown. In the current study, we investigated the roles of Kupffer cells, NKT cells, FasL, tumor necrosis factor (TNF), and superoxide in Con-A hepatitis in C57BL/6 mice. Removal of Kupffer cells using gadolinium chloride (GdCl(3)) from the liver completely inhibited Con-A hepatitis, whereas increased serum TNF and IFN-gamma levels were not inhibited at all. Unexpectedly, anti-FasL antibody pretreatment did not inhibit Con-A hepatitis, whereas it inhibited hepatic injury induced by a synthetic ligand of NKT cells, alpha-galactosylceramide. Furthermore, GdCl(3) pretreatment changed neither the activation-induced down-regulation of NK1.1 antigens as well as T cell receptors of NKT cells nor the increased expression of the CD69 activation antigen of hepatic T cells. CD68(+) Kupffer cells greatly increased in proportion in the early phase after Con-A injection; this increase was abrogated by GdCl(3) pretreatment. Anti-TNF antibody (Ab) pretreatment did not inhibit the increase of Kupffer cells, but it effectively suppressed superoxide/reactive oxygen production from Kupffer cells and the resulting hepatic injury. Conversely, depletion of NKT cells in mice by NK1.1 Ab pretreatment did suppress both the increase of CD68(+) Kupffer cells and Con-A hepatitis. Consistently, the diminution of oxygen radicals produced by Kupffer cells by use of free radical scavengers greatly inhibited Con-A hepatitis without suppressing cytokine production. However, adoptive transfer experiments also indicate that a close interaction/cooperation of Kupffer cells with NKT cells is essential for Con-A hepatitis. Superoxide produced by Kupffer cells may be the essential effector in Con-A hepatitis, and TNF and NKT cells support their activation and superoxide production.
Coppotelli, Bibiana Marina; Madueño, Laura; Loviso, Claudia Lorena; Macchi, Marianela; Neme Tauil, Ricardo Martin; Valacco, María Pía; Morelli, Irma Susana
2017-01-01
The present study describes the behavior of a natural phenanthrene-degrading consortium (CON), a synthetic consortium (constructed with isolated strains from CON) and an isolated strain form CON (Sphingobium sp. AM) in phenanthrene cultures to understand the interactions among the microorganisms present in the natural consortium during phenanthrene degradation as a sole carbon and energy source in liquid cultures. In the contaminant degradation assay, the defined consortium not only achieved a major phenanthrene degradation percentage (> 95%) but also showed a more efficient elimination of the intermediate metabolite. The opposite behavior occurred in the CON culture where the lowest phenanthrene degradation and the highest HNA accumulation were observed, which suggests the presence of positive and also negative interaction in CON. To consider the uncultured bacteria present in CON, a metagenomic library was constructed with total CON DNA. One of the resulting scaffolds (S1P3) was affiliated with the Betaproteobacteria class and resulted in a significant similarity with a genome fragment from Burkholderia sp. HB1 chromosome 1. A complete gene cluster, which is related to one of the lower pathways (meta-cleavage of catechol) involved in PAH degradation (ORF 31–43), mobile genetic elements and associated proteins, was found. These results suggest the presence of at least one other microorganism in CON besides Sphingobium sp. AM, which is capable of degrading PAH through the meta-cleavage pathway. Burkholderiales order was further found, along with Sphingomonadales order, by a metaproteomic approach, which indicated that both orders were metabolically active in CON. Our results show the presence of negative interactions between bacterial populations found in a natural consortium selected by enrichment techniques; moreover, the synthetic syntrophic processing chain with only one microorganism with the capability of degrading phenanthrene was more efficient in contaminant and intermediate metabolite degradation than a generalist strain (Sphingobium sp. AM). PMID:28886166
Monde, Kazuaki; Contreras-Galindo, Rafael; Kaplan, Mark H; Markovitz, David M; Ono, Akira
2012-10-01
Human endogenous retroviruses (HERVs), which are remnants of ancestral retroviruses integrated into the human genome, are defective in viral replication. Because activation of HERV-K and coexpression of this virus with HIV-1 have been observed during HIV-1 infection, it is conceivable that HERV-K could affect HIV-1 replication, either by competition or by cooperation, in cells expressing both viruses. In this study, we found that the release efficiency of HIV-1 Gag was 3-fold reduced upon overexpression of HERV-K(CON) Gag. In addition, we observed that in cells expressing Gag proteins of both viruses, HERV-K(CON) Gag colocalized with HIV-1 Gag at the plasma membrane. Furthermore, HERV-K(CON) Gag was found to coassemble with HIV-1 Gag, as demonstrated by (i) processing of HERV-K(CON) Gag by HIV-1 protease in virions, (ii) coimmunoprecipitation of virion-associated HERV-K(CON) Gag with HIV-1 Gag, and (iii) rescue of a late-domain-defective HERV-K(CON) Gag by wild-type (WT) HIV-1 Gag. Myristylation-deficient HERV-K(CON) Gag localized to nuclei, suggesting cryptic nuclear trafficking of HERV-K Gag. Notably, unlike WT HERV-K(CON) Gag, HIV-1 Gag failed to rescue myristylation-deficient HERV-K(CON) Gag to the plasma membrane. Efficient colocalization and coassembly of HIV-1 Gag and HERV-K Gag also required nucleocapsid (NC). These results provide evidence that HIV-1 Gag heteromultimerizes with HERV-K Gag at the plasma membrane, presumably through NC-RNA interaction. Intriguingly, HERV-K Gag overexpression reduced not only HIV-1 release efficiency but also HIV-1 infectivity in a myristylation- and NC-dependent manner. Altogether, these results indicate that Gag proteins of endogenous retroviruses can coassemble with HIV-1 Gag and modulate the late phase of HIV-1 replication.
Hemangioblastomas de fosa posterior: Reporte de 16 casos y revisión de la literatura
Campero, Alvaro; Ajler, Pablo; Fernandez, Julio; Isolan, Gustavo; Paiz, Martin; Rivadeneira, Conrado
2016-01-01
Resumen Objetivo: El propósito del presente trabajo es presentar los resultados de 16 pacientes con diagnóstico de hemangioblastoma de fosa posterior (HBFP), operados con técnicas microquirúrgicas. Método: Desde junio de 2005 a diciembre de 2015, 16 pacientes con diagnóstico de HBFP fueron intervenidos quirúrgicamente. Se evaluó: sexo, edad, tipo de lesión (quística con nódulo, quística sin nódulo, sólida y sólida-quística), sintomatología y resultados postoperatorios. Resultados: De los 16 pacientes intervenidos, 11 fueron varones y 5 mujeres. La edad promedio fue de 44 años. La forma más frecuente fue quística con nódulo (57%), seguida por forma sólida (31%). Un solo caso presentó la forma quística sin nódulo (6%), y uno solo la forma sólido-quística (6%). La sintomatología más frecuente fue cefalea acompañada de síndrome cerebeloso (43%), seguido de síndrome de hipertensión endocraneana (25%). En todos los casos la resección fue completa, siendo necesario en un caso una embolización previa. Como complicaciones postoperatorias, 2 pacientes presentaron ataxia (mejoró al cabo de 3 meses), y 1 paciente presentó una fístula de LCR (se solucionó con un drenaje espinal externo). Se registró un óbito por complicaciones postoperatorias. Conclusión: Lo más frecuente de ver en pacientes con HBFP es la forma quística con nódulo, siendo su sintomatología predominante la cefalea acompañada de síndrome cerebeloso. La resección quirúrgica completa es posible, con una baja tasa de morbimortalidad. PMID:27999708
Zhang, Qian; Sun, Xiaofang; Xiao, Xinhua; Zheng, Jia; Li, Ming; Yu, Miao; Ping, Fan; Wang, Zhixin; Qi, Cuijuan; Wang, Tong; Wang, Xiaojing
2017-01-01
Maternal undernutrition is linked with an elevated risk of diabetes mellitus in offspring regardless of the postnatal dietary status. This is also found in maternal micro-nutrition deficiency, especial chromium which is a key glucose regulator. We investigated whether maternal chromium restriction contributes to the development of diabetes in offspring by affecting DNA methylation status in liver tissue. After being mated with control males, female weanling 8-week-old C57BL mice were fed a control diet (CON, 1.19 mg chromium/kg diet) or a low chromium diet (LC, 0.14 mg chromium/kg diet) during pregnancy and lactation. After weaning, some offspring were shifted to the other diet (CON-LC, or LC-CON), while others remained on the same diet (CON-CON, or LC-LC) for 29 weeks. Fasting blood glucose, serum insulin, and oral glucose tolerance test was performed to evaluate the glucose metabolism condition. Methylation differences in liver from the LC-CON group and CON-CON groups were studied by using a DNA methylation array. Bisulfite sequencing was carried out to validate the results of the methylation array. Maternal chromium limitation diet increased the body weight, blood glucose, and serum insulin levels. Even when switched to the control diet after weaning, the offspring also showed impaired glucose tolerance and insulin resistance. DNA methylation profiling of the offspring livers revealed 935 differentially methylated genes in livers of the maternal chromium restriction diet group. Pathway analysis identified the insulin signaling pathway was the main process affected by hypermethylated genes. Bisulfite sequencing confirmed that some genes in insulin signaling pathway were hypermethylated in livers of the LC-CON and LC-LC group. Accordingly, the expression of genes in insulin signaling pathway was downregulated. There findings suggest that maternal chromium restriction diet results in glucose intolerance in male offspring through alterations in DNA methylation which is associated with the insulin signaling pathway in the mice livers. PMID:28072825
Zhang, Qian; Sun, Xiaofang; Xiao, Xinhua; Zheng, Jia; Li, Ming; Yu, Miao; Ping, Fan; Wang, Zhixin; Qi, Cuijuan; Wang, Tong; Wang, Xiaojing
2017-01-01
Maternal undernutrition is linked with an elevated risk of diabetes mellitus in offspring regardless of the postnatal dietary status. This is also found in maternal micro-nutrition deficiency, especial chromium which is a key glucose regulator. We investigated whether maternal chromium restriction contributes to the development of diabetes in offspring by affecting DNA methylation status in liver tissue. After being mated with control males, female weanling 8-week-old C57BL mice were fed a control diet (CON, 1.19 mg chromium/kg diet) or a low chromium diet (LC, 0.14 mg chromium/kg diet) during pregnancy and lactation. After weaning, some offspring were shifted to the other diet (CON-LC, or LC-CON), while others remained on the same diet (CON-CON, or LC-LC) for 29 weeks. Fasting blood glucose, serum insulin, and oral glucose tolerance test was performed to evaluate the glucose metabolism condition. Methylation differences in liver from the LC-CON group and CON-CON groups were studied by using a DNA methylation array. Bisulfite sequencing was carried out to validate the results of the methylation array. Maternal chromium limitation diet increased the body weight, blood glucose, and serum insulin levels. Even when switched to the control diet after weaning, the offspring also showed impaired glucose tolerance and insulin resistance. DNA methylation profiling of the offspring livers revealed 935 differentially methylated genes in livers of the maternal chromium restriction diet group. Pathway analysis identified the insulin signaling pathway was the main process affected by hypermethylated genes. Bisulfite sequencing confirmed that some genes in insulin signaling pathway were hypermethylated in livers of the LC-CON and LC-LC group. Accordingly, the expression of genes in insulin signaling pathway was downregulated. There findings suggest that maternal chromium restriction diet results in glucose intolerance in male offspring through alterations in DNA methylation which is associated with the insulin signaling pathway in the mice livers.
Coupé, Mickael; Bai, Yanqiang; Gauquelin-Koch, Guillemette; Jiang, Shizhong; Aubry, Patrick; Wan, Yumin; Custaud, Marc-Antoine; Li, Yinghui
2012-01-01
We quantified the impact of 60-day head-down bed rest (HDBR) with countermeasures on arterial and venous response to tilt. Methods: Twenty-one males: 7 control (Con), 7 resistive vibration exercise (RVE) and 7 Chinese herb (Herb) were assessed. Subjects were identified as finisher (F) or non-finishers (NF) at the post-HDBR 20-min tilt test. The cerebral (MCA), femoral (FEM) arterial flow velocity and leg vascular resistance (FRI), the portal vein section (PV), the flow redistribution ratios (MCA/FEM; MCA/PV), the tibial (Tib), gastrocnemius (Gast), and saphenous (Saph) vein sections were measured by echography and Doppler ultrasonography. Arterial and venous parameters were measured at 3-min pre-tilt in the supine position, and at 1 min before the end of the tilt. Results: At post-HDBR tilt, MCA decreased more compared with pre-HDBR tilt in the Con, RVE, and Herb groups, the MCA/FEM tended to decrease in the Con and Herb groups (not significant) but remained stable in the RVE gr. FRI dropped in the Con gr, but remained stable in the Herb gr and increased in the RVE gr. PV decreased less in the Con and Herb groups but remained unchanged in the RVE gr. MCA/PV decreased in the Con and Herb groups, but increased to a similar extent in the RVE gr. Gast section significantly increased more in the Con gr only, whereas Tib section increased more in the Con and Herb groups but not in the RVE gr. The percent change in Saph section was similar at pre- and post-HDBR tilt. Conclusion: In the Con gr, vasoconstriction was reduced in leg and splanchnic areas. RVE and Herb contributed to prevent the loss of vasoconstriction in both areas, but the effect of RVE was higher. RVE and Herb contributed to limit Gast distension whereas only RVE had a protective effect on the Tib. PMID:22412933
2013-01-01
Background Soy oil is a major vegetable oil consumed in the US. A recently developed soybean variety produces oil with a lower concentration of α-linolenic acid, hence a higher (n-6)/(n-3) ratio, than regular soy oil. The study was conducted to determine the metabolic impact of the low α-linolenic acid containing soy oil. Methods Ossabaw pigs were fed diets supplemented with either 13% regular soybean oil (SBO), or 13% of the low α-linolenic soybean oil (LLO) or a control diet (CON) without extra oil supplementation, for 8 weeks. Results Serum and adipose tissue α-linolenic acid concentration was higher in pigs fed the SBO diet than those on the CON and LLO diets. In the serum, the concentration of saturated fatty acids (SFA) was lower in the LLO group than in CON and SBO groups polyunsaturated fatty acid (PUFA) concentration was higher in the LLO group compared to CON and SBO groups. Glucose, insulin, triglycerides and LDL-cholesterol were higher in pigs fed the SBO diet than those fed the CON and LLO diets. HDL-cholesterol was lower in pigs on the SBO diet than those on the CON and LLO diets. Pigs fed SBO and LLO diets had lower CRP concentration than those on the CON diet. Adipose tissue expression of Interleukin 6 (IL-6) was higher in the SBO and LLO diets than the CON. Expression of ECM genes, COLVIA and fibronectin, was significantly reduced in the SBO diet relative to the CON and LLO diets whereas expression of inflammation-related genes, cluster of differentiation 68 (CD68) and monocyte chemoattractant protein 1 (MCP-1), was not different across treatments. Conclusions Results suggest that lowering the content of α-linolenic acid in the context of a high fat diet could lead to mitigation of development of hyperinsulinemia and dyslipidemia without significant effects on adipose tissue inflammation. PMID:23497195
Muthalib, Makii; Lee, Hoseong; Millet, Guillaume Y; Ferrari, Marco; Nosaka, Kazunori
2010-09-01
Eccentric contractions (ECC) require lower systemic oxygen (O2) and induce greater symptoms of muscle damage than concentric contractions (CON); however, it is not known if local muscle oxygenation is lower in ECC than CON during and following exercise. This study compared between ECC and CON for changes in biceps brachii muscle oxygenation [tissue oxygenation index (TOI)] and hemodynamics [total hemoglobin volume (tHb)=oxygenated-Hb+deoxygenated-Hb], determined by near-infrared spectroscopy over 10 sets of 6 maximal contractions of the elbow flexors of 10 healthy subjects. This study also compared between ECC and CON for changes in TOI and tHb during a 10-s sustained and 30-repeated maximal isometric contraction (MVC) task measured immediately before and after and 1-3 days following exercise. The torque integral during ECC was greater (P<0.05) than that during CON by approximately 30%, and the decrease in TOI was smaller (P<0.05) by approximately 50% during ECC than CON. Increases in tHb during the relaxation phases were smaller (P<0.05) by approximately 100% for ECC than CON; however, the decreases in tHb during the contraction phases were not significantly different between sessions. These results suggest that ECC utilizes a lower muscle O2 relative to O2 supply compared with CON. Following exercise, greater (P<0.05) decreases in MVC strength and increases in plasma creatine kinase activity and muscle soreness were evident 1-3 days after ECC than CON. Torque integral, TOI, and tHb during the sustained and repeated MVC tasks decreased (P<0.01) only after ECC, suggesting that muscle O2 demand relative to O2 supply during the isometric tasks was decreased after ECC. This could mainly be due to a lower maximal muscle mass activated as a consequence of muscle damage; however, an increase in O2 supply due to microcirculation dysfunction and/or inflammatory vasodilatory responses after ECC is recognized.
Yan, W Q; Yang, T S; Hou, L Z; Susuki, F; Kato, Y
1994-12-01
The effect of concanavalin A (Con A) on maturing and terminal differentiation in permanent chondrocyte cultures were examined. Chondrocytes isolated from permanent cartilage were seeded at low density and grown in MEM medium containing 10% fetal bovine serum, 50 micrograms/ml of ascorbic acid and antibiotics, at 37 degrees C under 50% CO2 in air. At 0.3% of low serum concentration, addition of Con A to the culture medium increased by 3- to 4-fold the incorporation of [35S] sulfate into large chondroitin sulfate proteoglycan that characteristically found in cartilage. Chemical analysis showed a 4-fold increase in the accumulation of macromolecular containing hexuronic acid in Con A-maintained cultures. The effect of Con A on [35S]sulfate incorporation into proteoglycan was greater than that of various growth factor or hormones. Brief exposure of the permanent chondrocytes to Con A (5 micrograms/ml) for 24 hours and subsequent incubation in its absence for 5-10 days resulted in 10- to 100-fold increase in alkaline phosphatase and binding of 1.25 (OH)2 vitamin D3 to cells. Treatment with Con A also resulted in 10- to 20-fold increase in calcium content and 45Ca incorporation into insoluble material. Methyl-D-mannopyranoside reversed the effect of Con A on [35S]sulfate incorporation into proteoglycan and alkaline phosphatase activity. Since other lectins, such as wheat germ agglutinin, lentil lectin, phytohemagglutinin, Ulex europeasu agglutinin and garden pea lectin had been tested to have little effect on [35S]sulfate incorporation into proteoglycans and induction of alkaline phosphatase activity, the Con A action on chondrocytes seems specific. These results indicate that Con A is a potent modulator of differentiation of chondrocytes, which induces the onset on a maturing and a terminal differentiation in chondrocytes, leading to extensive calcification of the extracellular matrix.
1988-04-01
and Cons . Major Thomas H. Cecil 88-0490 "--"insights into tomorrou,"’ ..v- A A 0 PtY-i f(.> i’I,-:::x:’~ --pcr~ j.~ ~~* --. -- iiV • DISCLAIMER The...k. r- r,’ I’. REPORT NUMBER 88-0490 TITLE WOMEN IN COMBAT-PROS AND CONS AUTHOR(S) MAJOR THOMAS H. CEC-IL, USAF -% FACULTY ADVISOR CH, LT COL DAVID W...NUMBERS 11 TITLE (include Security Classification) WOMEN IN COMBAT--PROS AND CONS 12. PERSON4AL AUTHOR(S) Cecil, Thomas H1., Major, USAF 9a YýOF REPORT
Esselburn, K M; O'Diam, K M; Hill, T M; Bateman, H G; Aldrich, J M; Schlotterbeck, R L; Daniels, K M
2013-09-01
Typical fatty acid profiles of milk and milk replacer (MR) differ. Calf MR in the United States are made from animal fat, which are low in short- and medium-chain fatty acids and linolenic acid. Two 56-d trials compared a control MR containing 27% crude protein and formulated with 3 fat and fatty acid compositions. The 3 MR treatments were (1) only animal fat totaling 17% fat (CON), (2) animal fat supplemented with butyrate, medium-chain fatty acids, and linolenic acid using a commercial product (1.25% NeoTec4 MR; Provimi North America, Brookville, OH) totaling 17% fat (fatty acid-supplemented; FA-S), and (3) milk fat totaling 33% fat (MF). The MR were fed at 660 g of dry matter from d 0 to 42 and weaned. Starter (20% crude protein) and water were fed ad libitum for 56 d. Trial 1 utilized Holstein calves (24 female, 24 male) during summer months and trial 2 utilized Holstein calves (48 male) during fall months. Calves (41±1 kg of initial body weight; 2 to 3d of age) were sourced from a single farm and housed in a naturally ventilated nursery without added heat. Calves were in individual pens with straw bedding. Calf was the experimental unit. Data for each trial were analyzed as a completely randomized design with a 3 (MR treatment) × 2 (sex) factorial arrangement of treatments in trial 1 with repeated measures and as a completely randomized design with 3 MR treatments in trial 2 with repeated measures. Preplanned contrast statements of treatments CON versus FA-S and CON versus MF were used to separate means. We found no interactions of MR treatment by sex. Calf average daily gain, hip width change, and feed efficiency differed (CON
Improving the Current DHS Capabilities Framework
2008-09-01
80 4. Pros and Cons .....................................................................................80 5. Performance Measurement... pros and cons . The chapter also provides a graphic of the proposed framework. • Chapter V – “The Road Ahead.” This chapter discovers and suggests...wheels, tires, tire pattern, tire width, and height to complement achieving the outcome. Finally, Jim considered the pros and cons of his new
Gómez, Luis Alberto; Montoya, Gladis; Rivera, Hernán Mauricio; Hernández, Juan Carlos
2017-04-01
Introducción. El virus del Zika (ZIKV) es un flavivirus con envoltura, transmitido a los seres humanos principalmente por el vector Aedes aegypti. La infección por ZIKV se ha asociado con un gran neurotropismo y con efectos neuropáticos, como el síndrome de Guillain-Barré en el adulto y la microcefalia fetal y posnatal, así como con un síndrome de infección congénita similar al producido por el virus de la rubéola (RV).Objetivo. Comparar las estructuras moleculares de la proteína de envoltura E del virus del Zika (E-ZIKV) y de la E1 del virus de la rubéola (E1-RV), y plantear posibles implicaciones en el neurotropismo y en las alteraciones del sistema nervioso asociadas con el ZIKV.Materiales y métodos. La secuencia de aminoácidos de la proteína E-ZIKV (PDB: 5iZ7) se alineó con la de la glucopreteína E1 del virus de la rubéola (PDB: 4ADG). Los elementos de la estructura secundaria se determinaron usando los programas Vector NTI Advance®, DSSP y POSA, así como herramientas de gestión de datos (AlignX®). Uno de los criterios principales de comparación y alineación fue la asignación de residuos estructuralmente equivalentes, con más de 70 % de identidad.Resultados. La organización estructural de la proteína E-ZIKV (PDB: 5iZ7) fue similar a la de E1-RV (PDB: 4ADG) (70 a 80 % de identidad), y se observó una correspondencia con la estructura definida para las glucoproteínas de fusión de membrana de clase II de los virus con envoltura. E-ZIKV y E1-RV exhibieron elementos estructurales de fusión muy conservados en la región distal del dominio II, asociados con la unión a los receptores celulares de entrada del virus de la rubéola (glucoproteína de mielina del oligodendrocito, Myelin Oligodendrocyte Glycoprotein, MOG), y con los receptores celulares Axl del ZIKV y de otros flavivirus.Conclusión. La comparación de las proteínas E-ZIKV y E1-RV es un paso necesario hacia la definición de otros factores moleculares determinantes del neurotropismo y la patogenia del ZIKV, el cual puede contribuir a generar estrategias de diagnóstico, prevención y tratamiento de las complicaciones neurológicas inducidas por el ZIKV.
Gunter, P; Schwellnus, M; Fuller, P
2004-01-01
Objective: To establish whether a local injection of methylprednisolone acetate (40 mg) is effective in decreasing pain during running in runners with recent onset (less than two weeks) iliotibial band friction syndrome (ITBFS). Methods: Eighteen runners with at least grade 2 ITBFS underwent baseline investigations including a treadmill running test during which pain was recorded on a visual analogue scale every minute. The runners were then randomly assigned to either the experimental (EXP; nine) or a placebo control (CON; nine) group. The EXP group was infiltrated in the area where the iliotibial band crosses the lateral femoral condyle with 40 mg methylprednisolone acetate mixed with a short acting local anaesthetic, and the CON group with short acting local anaesthetic only. The same laboratory based running test was repeated after seven and 14 days. The main measure of outcome was total pain during running (calculated as the area under the pain versus time graph for each running test). Results: There was a tendency (p = 0.07) for a greater decrease in total pain (mean (SEM)) during the treadmill running in the EXP group than the CON group tests from day 0 (EXP = 222 (71), CON = 197 (31)) to day 7 (EXP = 140 (87), CON = 178 (76)), but there was a significant decrease in total pain during running (p = 0.01) from day 7 (EXP = 140 (87), CON = 178 (76)) to day 14 (EXP = 103 (89), CON = 157 (109)) in the EXP group compared with the CON group. Conclusion: Local corticosteroid infiltration effectively decreases pain during running in the first two weeks of treatment in patients with recent onset ITBFS. PMID:15155424
Cue-based assertion classification for Swedish clinical text – developing a lexicon for pyConTextSwe
Velupillai, Sumithra; Skeppstedt, Maria; Kvist, Maria; Mowery, Danielle; Chapman, Brian E.; Dalianis, Hercules; Chapman, Wendy W.
2014-01-01
Objective The ability of a cue-based system to accurately assert whether a disorder is affirmed, negated, or uncertain is dependent, in part, on its cue lexicon. In this paper, we continue our study of porting an assertion system (pyConTextNLP) from English to Swedish (pyConTextSwe) by creating an optimized assertion lexicon for clinical Swedish. Methods and material We integrated cues from four external lexicons, along with generated inflections and combinations. We used subsets of a clinical corpus in Swedish. We applied four assertion classes (definite existence, probable existence, probable negated existence and definite negated existence) and two binary classes (existence yes/no and uncertainty yes/no) to pyConTextSwe. We compared pyConTextSwe’s performance with and without the added cues on a development set, and improved the lexicon further after an error analysis. On a separate evaluation set, we calculated the system’s final performance. Results Following integration steps, we added 454 cues to pyConTextSwe. The optimized lexicon developed after an error analysis resulted in statistically significant improvements on the development set (83% F-score, overall). The system’s final F-scores on an evaluation set were 81% (overall). For the individual assertion classes, F-score results were 88% (definite existence), 81% (probable existence), 55% (probable negated existence), and 63% (definite negated existence). For the binary classifications existence yes/no and uncertainty yes/no, final system performance was 97%/87% and 78%/86% F-score, respectively. Conclusions We have successfully ported pyConTextNLP to Swedish (pyConTextSwe). We have created an extensive and useful assertion lexicon for Swedish clinical text, which could form a valuable resource for similar studies, and which is publicly available. PMID:24556644
Varas-Díaz, Nelson; Neilands, Torsten B.; Guilamo-Ramos, Vincent; Cintrón Bou, Francheska N.
2009-01-01
El estigma relacionado con el VIH/SIDA continúa siendo un obstáculo para la prevención primaria y secundaria del VIH. Las consecuencias para las personas que viven con la enfermedad han sido muy documentadas y continúan siendo una gran preocupación para las personas que proveen servicios de salud y para aquellas que investigan el tema. Estas consecuencias son preocupantes cuando el estigma emana de profesionales de la salud porque se puede limitar el acceso a los servicios. Uno de los principales obstáculos para la investigación del estigma relacionado con el VIH en Puerto Rico es la falta de instrumentos cuantitativos para evaluar las manifestaciones del estigma entre profesionales de la salud. El objetivo principal de este estudio fue desarrollar y probar las propiedades psicométricas de una escala sobre el estigma relacionado con el VIH/SIDA culturalmente apropiada para personas que proveen servicios de salud puertorriqueñas y desarrollar una versión corta de la escala que pudiera usarse en escenarios clínicos con tiempo limitado. El instrumento desarrollado estuvo basado en evidencia cualitativa recopilada entre profesionales y estudiantes de profesiones de la salud puertorriqueños/as (n=80) y administrado a una muestra de 421 profesionales de la salud en adiestramiento. La escala contenía 12 dimensiones del estigma relacionado con el VIH/SIDA. El análisis cuantitativo corroboró 11 de ellas, teniendo como resultado un instrumento con validez y confiabilidad satisfactoria. Estas dimensiones, a su vez, fueron subcomponentes de un factor de estigma general superior. PMID:20333258
Identifying Subgroups among Hardcore Smokers: a Latent Profile Approach
Bommelé, Jeroen; Kleinjan, Marloes; Schoenmakers, Tim M.; Burk, William J.; van den Eijnden, Regina; van de Mheen, Dike
2015-01-01
Introduction Hardcore smokers are smokers who have little to no intention to quit. Previous research suggests that there are distinct subgroups among hardcore smokers and that these subgroups vary in the perceived pros and cons of smoking and quitting. Identifying these subgroups could help to develop individualized messages for the group of hardcore smokers. In this study we therefore used the perceived pros and cons of smoking and quitting to identify profiles among hardcore smokers. Methods A sample of 510 hardcore smokers completed an online survey on the perceived pros and cons of smoking and quitting. We used these perceived pros and cons in a latent profile analysis to identify possible subgroups among hardcore smokers. To validate the profiles identified among hardcore smokers, we analysed data from a sample of 338 non-hardcore smokers in a similar way. Results We found three profiles among hardcore smokers. ‘Receptive’ hardcore smokers (36%) perceived many cons of smoking and many pros of quitting. ‘Ambivalent’ hardcore smokers (59%) were rather undecided towards quitting. ‘Resistant’ hardcore smokers (5%) saw few cons of smoking and few pros of quitting. Among non-hardcore smokers, we found similar groups of ‘receptive’ smokers (30%) and ‘ambivalent’ smokers (54%). However, a third group consisted of ‘disengaged’ smokers (16%), who saw few pros and cons of both smoking and quitting. Discussion Among hardcore smokers, we found three distinct profiles based on perceived pros and cons of smoking. This indicates that hardcore smokers are not a homogenous group. Each profile might require a different tobacco control approach. Our findings may help to develop individualized tobacco control messages for the particularly hard-to-reach group of hardcore smokers. PMID:26207829
Park, Hun-Young; Kim, Jisu; Park, Miyoung; Chung, Nana; Lim, Kiwon
2018-01-01
[Purpose] The purpose of our study was to determine the effectiveness of carbohydrate loading by additional carbohydrate supplements for 7 days after prolonged interval exercise on exercise performance and energy metabolism during submaximal exercise in team-sports athletes. [Methods] Twenty male team-sports athletes (14 soccer and 6 rugby players) volunteered to participate in the study and were equally divided into the experimental group (EXP, n=10) performing additional carbohydrate supplementation for 7 days after prolonged interval exercise until blood glucose level reaches 50 mg/dL or less and the control group (CON, n=10). Then, maximal oxygen consumption (VO2max) and minute ventilation (VE), oxygen consumption (VO2), carbon dioxide excretion (VCO2), respiratory exchange ratio (RER), blood glucose level, and blood lactate level were measured in all team-sports players during submaximal exercise corresponding to 70% VO2max before and after intervention. [Results] There was no significant interaction in all parameters, but team-sports players in the EXP presented more improved VO2max (CON vs EXP = vs 5.3% vs 6.3%), VE (CON vs EXP = vs 3.8% vs 6.6%), VO2 (CON vs EXP = vs 8.5% vs 9.9%), VCO2 (CON vs EXP = vs 2.8% vs 4.0%), blood glucose level (CON vs EXP = vs -12.9% vs -7.6%), and blood lactate level (CON vs EXP = -18.2% vs -25%) compared to those in the CON. [Conclusion] These findings showed that additional carbohydrate supplementation conducted in our study is not effective in exercise performance and energy metabolism during submaximal exercise. PMID:29673243
Mincle Signaling Promotes Con-A Hepatitis
Greco, Stephanie H.; Torres-Hernandez, Alejandro; Kalabin, Aleksandr; Whiteman, Clint; Rokosh, Rae; Ravirala, Sushma; Ochi, Atsuo; Gutierrez, Johana; Salyana, Muhammad Atif; Mani, Vishnu R.; Nagaraj, Savitha V.; Deutsch, Michael; Seifert, Lena; Daley, Donnele; Barilla, Rocky; Hundeyin, Mautin; Nikifrov, Yuriy; Tejada, Karla; Gelb, Bruce E.; Katz, Steven C.; Miller, George
2016-01-01
Concanavalin-A (Con-A) hepatitis is regarded as a T cell-mediated model of acute liver injury. Mincle is a C-type lectin receptor (CLR) that is critical in the immune response to mycobacteria and fungi, but does not have a well-defined role in pre-clinical models of non-pathogen mediated inflammation. Since Mincle can ligate the cell death ligand SAP130, we postulated that Mincle signaling drives intrahepatic inflammation and liver injury in Con-A hepatitis. Acute liver injury was assessed in the murine Con-A hepatitis model using C57BL/6, Mincle−/−, and Dectin-1−/− mice. The role of C/EBPβ and HIF-1α signaling was assessed using selective inhibitors. We found that Mincle was highly expressed in hepatic innate inflammatory cells and endothelial cells in both mice and humans. Furthermore, sterile Mincle ligands and Mincle signaling intermediates were increased in the murine liver in Con-A hepatitis. Most significantly, Mincle deletion or blockade protected against Con-A hepatitis whereas Mincle ligation exacerbated disease. Bone marrow chimeric and adoptive transfer experiments suggested that Mincle signaling in infiltrating myeloid cells dictates disease phenotype. Conversely, signaling via other CLRs did not alter disease course. Mechanistically, we found that Mincle blockade decreased the NF-κβ related signaling intermediates, C/EBPβ and HIF-1α, both of which are necessary in macrophage-mediated inflammatory responses. Accordingly, Mincle deletion lowered production of nitrites in Con-A hepatitis and inhibition of both C/EBPβ and HIF1-α reduced the severity of liver disease. Our work implicates a novel innate immune driver of Con-A hepatitis and, more broadly, suggests a potential role for Mincle in diseases governed by sterile inflammation. PMID:27559045
Mincle Signaling Promotes Con A Hepatitis.
Greco, Stephanie H; Torres-Hernandez, Alejandro; Kalabin, Aleksandr; Whiteman, Clint; Rokosh, Rae; Ravirala, Sushma; Ochi, Atsuo; Gutierrez, Johana; Salyana, Muhammad Atif; Mani, Vishnu R; Nagaraj, Savitha V; Deutsch, Michael; Seifert, Lena; Daley, Donnele; Barilla, Rocky; Hundeyin, Mautin; Nikifrov, Yuriy; Tejada, Karla; Gelb, Bruce E; Katz, Steven C; Miller, George
2016-10-01
Con A hepatitis is regarded as a T cell-mediated model of acute liver injury. Mincle is a C-type lectin receptor that is critical in the immune response to mycobacteria and fungi but does not have a well-defined role in preclinical models of non-pathogen-mediated inflammation. Because Mincle can ligate the cell death ligand SAP130, we postulated that Mincle signaling drives intrahepatic inflammation and liver injury in Con A hepatitis. Acute liver injury was assessed in the murine Con A hepatitis model using C57BL/6, Mincle(-/-), and Dectin-1(-/-) mice. The role of C/EBPβ and hypoxia-inducible factor-1α (HIF-1α) signaling was assessed using selective inhibitors. We found that Mincle was highly expressed in hepatic innate inflammatory cells and endothelial cells in both mice and humans. Furthermore, sterile Mincle ligands and Mincle signaling intermediates were increased in the murine liver in Con A hepatitis. Most significantly, Mincle deletion or blockade protected against Con A hepatitis, whereas Mincle ligation exacerbated disease. Bone marrow chimeric and adoptive transfer experiments suggested that Mincle signaling in infiltrating myeloid cells dictates disease phenotype. Conversely, signaling via other C-type lectin receptors did not alter disease course. Mechanistically, we found that Mincle blockade decreased the NF-κβ-related signaling intermediates C/EBPβ and HIF-1α, both of which are necessary in macrophage-mediated inflammatory responses. Accordingly, Mincle deletion lowered production of nitrites in Con A hepatitis and inhibition of both C/EBPβ and HIF-1α reduced the severity of liver disease. Our work implicates a novel innate immune driver of Con A hepatitis and, more broadly, suggests a potential role for Mincle in diseases governed by sterile inflammation. Copyright © 2016 by The American Association of Immunologists, Inc.
The Effects of Crushed Ice Ingestion Prior to Steady State Exercise in the Heat.
Zimmermann, Matthew; Landers, Grant; Wallman, Karen E; Saldaris, Jacinta
2017-06-01
This study examined the physiological effects of crushed ice ingestion before steady state exercise in the heat. Ten healthy males with age (23 ± 3 y), height (176.9 ± 8.7 cm), body-mass (73.5 ± 8.0 kg), VO 2peak (48.5 ± 3.6 mL∙kg∙min -1 ) participated in the study. Participants completed 60 min of cycling at 55% of their VO 2peak preceded by 30 min of precooling whereby 7 g∙kg -1 of thermoneutral water (CON) or crushed ice (ICE) was ingested. The reduction in T c at the conclusion of precooling was greater in ICE (-0.9 ± 0.3 °C) compared with CON (-0.2 ± 0.2 °C) (p ≤ .05). Heat storage capacity was greater in ICE compared with CON after precooling (ICE -29.3 ± 4.8 W∙m -2 ; CON -11.1 ± 7.3 W∙m -2 , p < .05). Total heat storage was greater in ICE compared with CON at the end of the steady state cycle (ICE 62.0 ± 12.5 W∙m-2; CON 49.9 ± 13.4 W∙m -2 , p < .05). Gross efficiency was higher in ICE compared with CON throughout the steady state cycle (ICE 21.4 ± 1.8%; CON 20.4 ± 1.9%, p < .05). Ice ingestion resulted in a lower thermal sensation at the end of precooling and a lower sweat rate during the initial stages of cycling (p < .05). Sweat loss, respiratory exchange ratio, heart rate and ratings of perceived exertion and thirst were similar between conditions (p > .05). Precooling with crushed ice led to improved gross efficiency while cycling due to an increased heat storage capacity, which was the result of a lower core temperature.
Selective Capture of Glycoproteins Using Lectin-modified Nanoporous Gold Monolith
Alla, Allan J.; d’Andrea, Felipe B.; Bhattarai, Jay K.; Cooper, Jared A.; Tan, Yih Horng; Demchenko, Alexei V.; Stine, Keith J.
2015-01-01
The surface of nanoporous gold (np-Au) monoliths was modified via a flow method with the lectin Concanavalin A (Con A) to develop a substrate for separation and extraction of glycoproteins. Self-assembled monolayers (SAMs) of lipoic acid (LA) on the np-Au monoliths were prepared followed by activation of the terminal carboxyl groups to create amine reactive esters that were utilized in the immobilization of Con A. Thermogravimetric analysis (TGA) was used to determine the surface coverages of LA and Con A on np-Au monoliths which were found to be 1.31 × 1018 molecules m−2 and 1.85 × 1015 molecules m−2, respectively. An in situ solution depletion method was developed that enabled surface coverage characterization without damaging the substrate and suggesting the possibility of regeneration. Using this method, the surface coverages of LA and Con A were found to be 0.989 ×1018 molecules m−2 and 1.32 × 1015 molecules m−2, respectively. The selectivity of the Con A-modified np-Au monolith for the high mannose-containing glycoprotein ovalbumin (OVA) versus negative control non-glycosylated bovine serum albumin (BSA) was demonstrated by the difference in the ratio of the captured molecules to the immobilized Con A molecules, with OVA:Con A = 2.3 and BSA:Con A = 0.33. Extraction of OVA from a 1:3 mole ratio mixture with BSA was demonstrated by the greater amount of depletion of OVA concentration during the circulation with the developed substrate. A significant amount of captured OVA was eluted using α-methyl mannopyranoside as a competitive ligand. This work is motivated by the need to develop new materials for chromatographic separation and extraction substrates for use in preparative and analytical procedures in glycomics. PMID:26554297
Zhao, P. Y.; Baek, H. Y.; Kim, I. H.
2012-01-01
An experiment was conducted to evaluate the effects of bacteriophage supplementation on egg performance, egg quality, excreta microflora, and moisture content in laying hens. A total of 288 Hy-line brown commercial laying hens (36-wk-old) were randomly allotted to 4 treatments in this 6-wk trial and dietary treatments included: i) CON, basal diet; ii) T1, CON+0.020% bacteriophage; iii) T2, CON+0.035% bacteriophage; iv) T3, CON+0.050% bacteriophage. There were 6 replicates for each treatment with 6 adjacent cages (2 hens/cage). Laying hens in T2 and T3 treatments had higher (p<0.05) egg production than those in CON and T1 treatments during wk 0 to 3. In addition, egg production in T1, T2, and T3 treatments was increased (p<0.05) compared with that in CON treatment during wk 4 to 6. At wk 4 and 5, birds in T2 group had higher (p<0.05) HU than those in CON. In addition, at wk 5 and 6, HU in birds fed T1 and T3 diets was greater (p<0.05) than those fed CON diet. E. coli and Salmonella spp. concentrations in excreta were decreased (p<0.05) by T1, T2, and T3 treatments. However, egg weight, egg shell color, yolk height, yolk color unit, egg shell strength, egg shell thickness, egg gravity, and excreta moisture content were not influenced by dietary treatments during the entire experimental period. In conclusion, bacteriophage supplementation has beneficial effects on egg production, egg albumen, and excreta microflora concentration in laying hens. PMID:25049658
Emergence of linezolid-resistant coagulase-negative staphylococci in an intensive care unit.
Balandin, Bárbara; Lobo, Beatriz; Orden, Beatriz; Román, Federico; García, Elena; Martínez, Rocío; Valdivia, Miguel; Ortega, Alfonso; Fernández, Inmaculada; Galdos, Pedro
2016-01-01
The aim of this study was to report the emergence of linezolid-resistant coagulase-negative staphylococci (CoNS) in an intensive care unit. An observational study was conducted in critically ill patients with colonization or infection by linezolid-resistant CoNS between January 2010 and December 2014. We analyzed the epidemiological and clinical features, and the mechanism of resistance to linezolid. We also evaluated the association between the incidence of linezolid-resistant CoNS strains and the consumption of linezolid in the study period. During the study period 49 patients had a linezolid-resistant CoNS strain isolated from clinical samples (blood in 42 cases, urine in 6, peritoneal fluid in 1). Molecular study showed a combination of mechanisms of resistance. Most patients were critically ill (APACHE II score = 21.9 ± 8.3) and nearly all had undergone surgery and invasive procedures, and had prior exposure to antibiotics. Linezolid-resistant CoNS were considered to be contaminants in 42 patients and associated with infection in 7 patients, comprising bacteremia and septic shock in most of them. They were successfully treated with glycopeptides or daptomycin. A modest significant correlation was observed between the decrease in linezolid consumption and the lower incidence of resistant isolates. Linezolid-resistant CoNS had emerged in critically ill patients with severe underlying diseases and prior antibiotic exposure. Most isolates represented colonization; however, linezolid-resistant CoNS can produce serious infections in critically ill patients. Glycopeptides and daptomycin seem to provide useful alternatives for therapy of these infections. A relationship was found between linezolid consumption and the incidence of linezolid-resistant CoNS strains.
Sjøgaard, Gisela; Rosendal, Lars; Kristiansen, Jesper; Blangsted, Anne K; Skotte, Jørgen; Larsson, Britt; Gerdle, Björn; Saltin, Bengt; Søgaard, Karen
2010-03-01
The aim of this investigation was to study female workers active in the labour market for differences between those with trapezius myalgia (MYA) and without (CON) during repetitive pegboard (PEG) and stress (STR) tasks regarding (1) relative muscle load, (2) trapezius muscle blood flow, (3) metabolite accumulation, (4) oxygenation, and (5) pain development. Among 812 female employees (age 30-60 years) at 7 companies with high prevalence of neck/shoulder complaints, clinical examination identified 43 MYA and 19 CON. At rest, during PEG, and STR the trapezius muscle was measured using (1) EMG and MMG, (2) microdialysis, and (3) NIRS. Further, subjective pain ratings were scored (VAS). EMGrms in %MVE (Maximal Voluntary EMG-activity), was significantly higher among MYA than CON during PEG (11.74 +/- 9.09 vs. 7.42 +/- 5.56%MVE) and STR (5.47 +/- 5.00 vs. 3.28 +/- 1.94%MVE). MANOVA showed a group and time effect regarding data from the microdialysis: for MYA versus CON group differences demonstrated lower muscle blood flow and higher lactate and pyruvate concentrations. Potassium and glucose only showed time effects. NIRS showed similar initial decreases in oxygenation with PEG in both groups, but only in CON a significant increase back to baseline during PEG. VAS score at rest was highest among MYA and increased during PEG, but not for CON. The results showed significant differences between CON and MYA regarding muscle metabolism at rest and with PEG and STR. Higher relative muscle load during PEG and STR, insufficient muscle blood flow and oxygenation may account for the higher lactate, pyruvate and pain responses among MYA versus CON.
Park, Hun-Young; Kim, Jisu; Park, Miyoung; Chung, Nana; Lim, Kiwon
2018-03-30
The purpose of our study was to determine the effectiveness of carbohydrate loading by additional carbohydrate supplements for 7 days after prolonged interval exercise on exercise performance and energy metabolism during submaximal exercise in team-sports athletes. Twenty male team-sports athletes (14 soccer and 6 rugby players) volunteered to participate in the study and were equally divided into the experimental group (EXP, n=10) performing additional carbohydrate supplementation for 7 days after prolonged interval exercise until blood glucose level reaches 50 mg/dL or less and the control group (CON, n=10). Then, maximal oxygen consumption (VO2max) and minute ventilation (VE), oxygen consumption (VO2), carbon dioxide excretion (VCO2), respiratory exchange ratio (RER), blood glucose level, and blood lactate level were measured in all team-sports players during submaximal exercise corresponding to 70% VO2max before and after intervention. There was no significant interaction in all parameters, but team-sports players in the EXP presented more improved VO2max (CON vs EXP = vs 5.3% vs 6.3%), VE (CON vs EXP = vs 3.8% vs 6.6%), VO2 (CON vs EXP = vs 8.5% vs 9.9%), VCO2 (CON vs EXP = vs 2.8% vs 4.0%), blood glucose level (CON vs EXP = vs -12.9% vs -7.6%), and blood lactate level (CON vs EXP = -18.2% vs -25%) compared to those in the CON. These findings showed that additional carbohydrate supplementation conducted in our study is not effective in exercise performance and energy metabolism during submaximal exercise. ©2018 The Korean Society for Exercise Nutrition.
Shashidhar, Ravindranath; Bandekar, Jayant R
2006-01-01
A radiation-resistant, Gram-negative and pleomorphic bacterium (CON-1) was isolated from a contaminated tryptone glucose yeast extract agar plate in the laboratory. It was red pigmented, nonmotile, nonsporulating, and aerobic, and contained MK-8 as respiratory quinone. The cell wall of this bacterium contained ornithine. The major fatty acids were C16:0, C16:1, C17:0, C18:1 and iso C18:0. The DNA of CON-1 had a G+C content of 70 mol%. Phylogenetic analysis based on 16S rRNA gene sequences showed that CON-1 exhibited a maximum similarity (94.72%) with Deinococcus grandis. Based on the genotypic, phenotypic and chemotaxonomic characteristics, the bacterium CON-1 was identified as a new species of the genus Deinococcus, for which the name Deinococcus mumbaiensis sp. nov. is proposed. The type strain of D. mumbaiensis is CON-1 (MTCC 7297(T)=DSM 17424(T)).
NASA Astrophysics Data System (ADS)
Nieva, M. F.; Pintado, O. I.; Adelman, S.; Rayle, K. E.; Sanders, S. E., Jr.
Las temperaturas efectivas (Teff) y gravedades superficiales (log g) de un grupo de estrellas de tipo B y A de Secuencia Principal se determinaron en varias etapas. En una primera aproximación se usaron los índices fotométricos de Strömgren para realizar el cálculo con el programa de Napiwotski et al.(1993). Luego se hizo un ajuste comparando datos espectrofotométricos con flujos obtenidos con el modelo ATLAS9 en la región visible. Y a continuación se hizo un mejor ajuste comparando los perfiles de la línea Hγ con espectros sintéticos calculados con SYNTHE. Además, se analizó el efecto de usar el modelo de Canuto y Mazzitelli (1991), donde se considera The Mixing Length Theory, en modelos de atmósferas de estrellas.
Creating an Effective Multi-Domain Wide-Area Surveillance Platform to Enhance Border Security
2008-03-01
SWOT ANALYSIS ........................................................................................43 I. ANALYSIS OF PROS AND CONS ...weaknesses and opportunities and SWOT analysis was also used to build pros and cons for the platform. All the interviewees liked unmanned platforms...because of the reduced night hour’s operations and SWOT analysis was also used to build pros and cons for the platform. All the interviewees really
ConKit: a python interface to contact predictions.
Simkovic, Felix; Thomas, Jens M H; Rigden, Daniel J
2017-07-15
Recent advances in protein residue contact prediction algorithms have led to the emergence of many new methods and a variety of file formats. We present ConKit , an open source, modular and extensible Python interface which allows facile conversion between formats and provides an interface to analyses of sequence alignments and sets of contact predictions. ConKit is available via the Python Package Index. The documentation can be found at http://www.conkit.org . ConKit is licensed under the BSD 3-Clause. hlfsimko@liverpool.ac.uk or drigden@liverpool.ac.uk. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.
PEGylation of Concanavalin A to decrease nonspecific interactions in a fluorescent glucose sensor
NASA Astrophysics Data System (ADS)
Abraham, Alexander A.; Cummins, Brian M.; Locke, Andrea K.; Grunlan, Melissa A.; Coté, Gerard L.
2014-02-01
The ability of people with diabetes to both monitor and regulate blood sugar levels is limited by the conventional "finger-prick" test that provides intermittent, single point measurements. Toward the development of a continuous glucose monitoring (CGM) system, the lectin, Concanavalin A (ConA), has been utilized as a component in a Förster resonance energy transfer (FRET), competitive glucose binding assay. Recently, to avoid reversibility problems associated with ConA aggregation, a suitable competing ligand labeled with 8-aminopyrene-1,3,6-trisulfonic acid trisodium salt (APTS) has been engineered. However, its ability to function as part of a glucose sensing assay is compromised due to the negative charge (at physiological pH) of native ConA that gives rise to non-specific binding with other ConA groups as well as with electrostatically charged assay-delivery carriers. To minimize these undesirable interactions, we have conjugated ConA with monomethoxy-poly(ethylene glycol) (mPEG) (i.e. "PEGylation"). In this preliminary research, fluorescently-labeled ConA was successfully PEGylated with mPEG-Nhydroxylsuccinimide( succinimidyl carbonate) (mPEG-NHS(SC)). The FRET response of APTS-labeled competing ligand (donor) conveyed an increase in the fluorescence intensity with increasing glucose concentrations.
Li, Sainan; Xia, Yujing; Chen, Kan; Li, Jingjing; Liu, Tong; Wang, Fan; Lu, Jie; Zhou, Yingqun; Guo, Chuanyong
2016-01-01
Background Epigallocatechin-3-gallate (EGCG) is the most effective compound in green tea, and possesses a wide range of beneficial effects, including anti-inflammatory, antioxidant, antiobesity, and anticancer effects. In this study, we investigated the protective effects of EGCG in concanavalin A (ConA)-induced hepatitis in mice and explored the possible mechanisms involved in these effects. Methods Balb/C mice were injected with ConA (25 mg/kg) to induce acute autoimmune hepatitis, and EGCG (10 or 30 mg/kg) was administered orally twice daily for 10 days before ConA injection. Serum liver enzymes, proinflammatory cytokines, and other marker proteins were determined 2, 8, and 24 hours after the ConA administration. Results BNIP3 mediated cell apoptosis and autophagy in ConA-induced hepatitis. EGCG decreased the immunoreaction and pathological damage by reducing inflammatory factors, such as TNF-α, IL-6, IFN-γ, and IL-1β. EGCG also exhibited an antiapoptotic and antiautophagic effect by inhibiting BNIP3 via the IL-6/JAKs/STAT3 pathway. Conclusion EGCG attenuated liver injury in ConA-induced hepatitis by downregulating IL-6/JAKs/STAT3/BNIP3-mediated apoptosis and autophagy. PMID:26929598
Influence of protic ionic liquids on the structure and stability of succinylated Con A.
Attri, Pankaj; Venkatesu, Pannuru
2012-01-01
We report the synthesis of a series of ionic liquids (ILs) from various ions having different kosmotropicity including dihydrogen phosphate (H(2)PO(4)(-)), hydrogen sulfate (HSO(4)(-)) and acetate (CH(3)COO(-)) as anions and chaotropic cation such as trialkylammonium cation. To characterize the biomolecular interactions of ILs with protein, we have explored the stability of succinylated Con A (S Con A) in the presence of these aqueous ILs, which are varied combinations of kosmotropic anion with chaotropic cation such as triethylammonium dihydrogen phosphate [(CH(3)CH(2))(3)NH][H(2)PO(4)] (TEAP), trimethylammonium acetate [(CH(3))(3)NH][CH(3)COO] (TMAA), trimethylammonium dihydrogen phosphate [(CH(3))(3)NH][H(2)PO(4)] (TMAP) and trimethylammonium hydrogen sulfate [(CH(3))(3)NH][HSO(4)] (TMAS). Circular dichroism (CD) and fluorescence experiments have been used to characterize the stability of S Con A by ILs. Our data distinctly demonstrate that the long alkyl chain IL TEAP is a strong stabilizer for S Con A. Further, our experimental results reveal that TEAP is an effective refolding enhancer for S Con A from a thermally denatured protein structure. Copyright © 2012 Elsevier B.V. All rights reserved.
Comportamiento del Helio en estrellas químicamente peculiares
NASA Astrophysics Data System (ADS)
Malaroda, S. M.; López García, Z.; Leone, F.; Catalano, F.
Las estrellas químicamente peculiares (CP) se caracterizan por tener deficiencias y sobreabundancias de algunos elementos químicos de hasta 106 veces la abundancia solar. Además presentan variaciones en las líneas espectrales. Se piensa que ello se debe a que los campos magnéticos presentes en este tipo de estrellas son principalmente dipolares, con un eje de simetría diferente del eje de rotación. La distribución de los elementos sobreabundantes y deficientes no es homogénea sobre la superficie estelar y las variaciones observadas serían una consecuencia directa de la rotación estelar. Entre los elementos con abundancia anómala se encuentra el Helio, cuyas líneas tienen intensidades que no son consistentes con una abundancia normal, que no puede ser determinada del modo usual, o sea, considerando una atmósfera con composición solar. Con el fin de determinar la abundancia de este elemento, se inició un estudio de estrellas anómalas de Helio, Hew y He strong. Además se determinarán las abundancias de otros elementos anómalos como ser el Si, Cr, Mg, Mn y Fe. Las mismas se determinan del modo tradicional, o sea: a) medida de los anchos equivalentes de las líneas de los distintos elementos analizados; b) adopción de la temperatura efectiva, gravedad y abundancia del Helio; c) cálculo del modelo de atmósfera d) comparación con las observaciones y reinicio de un proceso iterativo hasta lograr un acuerdo entre todos los parámetros analizados. Las observaciones se llevaron a cabo en el Complejo Astronómico El Leoncito. Se observaron setenta y ocho estrellas anómalas de Helio. En este momento se está procediendo a calcular las abundancias correspondientes a los distintos elementos químicos. Para ello se hace uso de los modelos de Kurucz, ATLAS9. Los cálculos NLTE de las líneas de Helio se llevan a cabo con el programa MULTI y se compararán con los realizados con el programa WIDTH9 de Kurucz (LTE), con el objeto de resaltar la importancia de los efectos NLTE.
The effects of cranial cooling during recovery on subsequent uncompensable heat stress tolerance.
Wallace, Phillip J; Masbou, Anaïs T; Petersen, Stewart R; Cheung, Stephen S
2015-08-01
This study compared cranial (CC) with passive (CON) cooling during recovery on tolerance to subsequent exercise while wearing firefighting protective ensemble and self-contained breathing apparatus in a hot-humid environment. Eleven males (mean ± SD; age, 30.9 ± 9.2 years; peak oxygen consumption, 49.5 ± 5.1 mL · kg(-1) · min(-1)) performed 2 × 20 min treadmill walks (5.6 km · h(-1), 4% incline) in 35 °C and 60% relative humidity. During a 20-min recovery (rest), participants sat and removed gloves, helmets, and flash hoods but otherwise remained encapsulated. A close-fitting liquid-perfused hood pumped 13 °C water at ∼ 500 mL · min(-1) through the head and neck (CC) or no cooling hood was worn (CON). During rest, neck temperature was lower in CC compared with CON from 4 min (CC: 35.73 ± 3.28 °C, CON: 37.66 ± 1.35 °C, p = 0.025) until the end (CC: 33.06 ± 4.70 °C, CON: 36.85 ± 1.63 °C, p = 0.014). Rectal temperature rose in both CC (0.11 ± 0.19 °C) and CON (0.26 ± 0.15 °C) during rest, with nonsignificant interaction between conditions (p = 0.076). Perceived thermal stress was lower (p = 0.006) from 5 min of CC (median: 3 (quartile 1: 3, quartile 3: 4)) until the end of rest compared with CON (median: 4 (quartile 1: 4, quartile 3: 4)). However, there were no significant differences (p = 0.906) in tolerance times during the second exercise between CC (16.55 ± 1.14 min) and CON (16.60 ± 1.31 min), nor were there any difference in rectal temperature at the start (CC: 38.30 ± 0.40 °C, CON: 38.40 ± 0.16 °C, p = 0.496) or at the end (CC: 38.82 ± 0.23 °C, CON: 39.07 ± 0.22 °C, p = 0.173). With high ambient heat and encapsulation, cranial and neck cooling during recovery decreases physiological strain and perceived thermal stress, but is ineffective in improving subsequent uncompensable heat stress tolerance.
Stähli, Barbara E.; Nguyen-Kim, Thi Dan Linh; Gebhard, Cathérine; Frauenfelder, Thomas; Tanner, Felix C.; Nietlispach, Fabian; Maisano, Francesco; Falk, Volkmar; Lüscher, Thomas F.; Maier, Willibald; Binder, Ronald K.
2015-01-01
Low-flow low-gradient severe aortic stenosis (LFLGAS) is associated with worse outcomes. Aortic valve calcification patterns of LFLGAS as compared to non-LFLGAS have not yet been thoroughly assessed. 137 patients undergoing transcatheter aortic valve replacement (TAVR) with preprocedural multidetector computed tomography (MDCT) and postprocedural transthoracic echocardiography were enrolled. Calcification characteristics were assessed by MDCT both for the total aortic valve and separately for each leaflet. 34 patients had LFLGAS and 103 non-LFLGAS. Total aortic valve calcification volume (p < 0.001), mass (p < 0.001), and density (p = 0.004) were lower in LFLGAS as compared to non-LFLGAS patients. At 30-day follow-up, mean transaortic pressure gradients and more than mild paravalvular regurgitation did not differ between groups. In conclusion, LFLGAS and non-LFLGAS express different calcification patterns which, however, did not impact on device success after TAVR. PMID:26435875
NASA Astrophysics Data System (ADS)
Gómez-Ros, J. M.; Bedogni, R.; Moraleda, M.; Delgado, A.; Romero, A.; Esposito, A.
2010-01-01
This communication describes an improved design for a neutron spectrometer consisting of 6Li thermoluminescent dosemeters located at selected positions within a single moderating polyethylene sphere. The spatial arrangement of the dosemeters has been designed using the MCNPX Monte Carlo code to calculate the response matrix for 56 log-equidistant energies from 10 -9 to 100 MeV, looking for a configuration that permits to obtain a nearly isotropic response for neutrons in the energy range from thermal to 20 MeV. The feasibility of the proposed spectrometer and the isotropy of its response have been evaluated by simulating exposures to different reference and workplace neutron fields. The FRUIT code has been used for unfolding purposes. The results of the simulations as well as the experimental tests confirm the suitability of the prototype for environmental and workplace monitoring applications.
Small bowel volvulus with jejunal diverticulum: Primary or secondary?
Shen, Xiao-Fei; Guan, Wen-Xian; Cao, Ke; Wang, Hao; Du, Jun-Feng
2015-09-28
Small bowel volvulus, which is torsion of the small bowel and its mesentery, is a medical emergency, and is categorized as primary or secondary type. Primary type often occurs without any apparent intrinsic anatomical anomalies, while the secondary type is common clinically and could be caused by numerous factors including postoperative adhesions, intestinal diverticulum, and/or tumors. Here, we report a rare case of a 60-year-old man diagnosed with small bowel volvulus using multidetector computed tomography (MDCT) angiography. Further discovery by laparotomy showed one jejunal diverticulum, longer corresponding mesentery with a narrower insertion, and a lack of mesenteric fat. This case report includes several etiological factors of small bowel volvulus, and we discuss the possible cause of small bowel volvulus in this patient. We also highlight the importance of MDCT angiography in the diagnosis of volvulus and share our experience in treating this disease.
Small bowel volvulus with jejunal diverticulum: Primary or secondary?
Shen, Xiao-Fei; Guan, Wen-Xian; Cao, Ke; Wang, Hao; Du, Jun-Feng
2015-01-01
Small bowel volvulus, which is torsion of the small bowel and its mesentery, is a medical emergency, and is categorized as primary or secondary type. Primary type often occurs without any apparent intrinsic anatomical anomalies, while the secondary type is common clinically and could be caused by numerous factors including postoperative adhesions, intestinal diverticulum, and/or tumors. Here, we report a rare case of a 60-year-old man diagnosed with small bowel volvulus using multidetector computed tomography (MDCT) angiography. Further discovery by laparotomy showed one jejunal diverticulum, longer corresponding mesentery with a narrower insertion, and a lack of mesenteric fat. This case report includes several etiological factors of small bowel volvulus, and we discuss the possible cause of small bowel volvulus in this patient. We also highlight the importance of MDCT angiography in the diagnosis of volvulus and share our experience in treating this disease. PMID:26420976
NASA Astrophysics Data System (ADS)
Petruse, Radu Emanuil; Batâr, Sergiu; Cojan, Adela; Maniţiu, Ioan
2014-11-01
Coronary computed tomography angiography (CCTA) allows coronary artery visualization and the detection of coronary stenoses. In addition; it has been suggested as a novel, noninvasive modality for coronary atherosclerotic plaque detection, characterization, and quantification. Accurate identification of coronary plaques is challenging, especially for the noncalcified plaques, due to many factors such as the small size of coronary arteries, reconstruction artifacts caused by irregular heartbeats, beam hardening, and partial volume averaging. The development of 16, 32, 64 and the latest 320 row multidetector CT not only increases the spatial and the temporal resolution significantly, but also increases the number of images to be interpreted by radiologists substantially. Radiologists have to visually examine each coronary artery for suspicious stenosis using visualization tools such as multiplanar reformatting (MPR) and curved planar reformatting (CPR) provided by the review workstation in clinical practice