Fleury, Eduardo F C; Gianini, Ana Claudia; Marcomini, Karem; Oliveira, Vilmar
2018-01-01
To determine the applicability of a computer-aided diagnostic system strain elastography system for the classification of breast masses diagnosed by ultrasound and scored using the criteria proposed by the breast imaging and reporting data system ultrasound lexicon and to determine the diagnostic accuracy and interobserver variability. This prospective study was conducted between March 1, 2016, and May 30, 2016. A total of 83 breast masses subjected to percutaneous biopsy were included. Ultrasound elastography images before biopsy were interpreted by 3 radiologists with and without the aid of computer-aided diagnostic system for strain elastography. The parameters evaluated by each radiologist results were sensitivity, specificity, and diagnostic accuracy, with and without computer-aided diagnostic system for strain elastography. Interobserver variability was assessed using a weighted κ test and an intraclass correlation coefficient. The areas under the receiver operating characteristic curves were also calculated. The areas under the receiver operating characteristic curve were 0.835, 0.801, and 0.765 for readers 1, 2, and 3, respectively, without computer-aided diagnostic system for strain elastography, and 0.900, 0.926, and 0.868, respectively, with computer-aided diagnostic system for strain elastography. The intraclass correlation coefficient between the 3 readers was 0.6713 without computer-aided diagnostic system for strain elastography and 0.811 with computer-aided diagnostic system for strain elastography. The proposed computer-aided diagnostic system for strain elastography system has the potential to improve the diagnostic performance of radiologists in breast examination using ultrasound associated with elastography.
Computer-aided US diagnosis of breast lesions by using cell-based contour grouping.
Cheng, Jie-Zhi; Chou, Yi-Hong; Huang, Chiun-Sheng; Chang, Yeun-Chung; Tiu, Chui-Mei; Chen, Kuei-Wu; Chen, Chung-Ming
2010-06-01
To develop a computer-aided diagnostic algorithm with automatic boundary delineation for differential diagnosis of benign and malignant breast lesions at ultrasonography (US) and investigate the effect of boundary quality on the performance of a computer-aided diagnostic algorithm. This was an institutional review board-approved retrospective study with waiver of informed consent. A cell-based contour grouping (CBCG) segmentation algorithm was used to delineate the lesion boundaries automatically. Seven morphologic features were extracted. The classifier was a logistic regression function. Five hundred twenty breast US scans were obtained from 520 subjects (age range, 15-89 years), including 275 benign (mean size, 15 mm; range, 5-35 mm) and 245 malignant (mean size, 18 mm; range, 8-29 mm) lesions. The newly developed computer-aided diagnostic algorithm was evaluated on the basis of boundary quality and differentiation performance. The segmentation algorithms and features in two conventional computer-aided diagnostic algorithms were used for comparative study. The CBCG-generated boundaries were shown to be comparable with the manually delineated boundaries. The area under the receiver operating characteristic curve (AUC) and differentiation accuracy were 0.968 +/- 0.010 and 93.1% +/- 0.7, respectively, for all 520 breast lesions. At the 5% significance level, the newly developed algorithm was shown to be superior to the use of the boundaries and features of the two conventional computer-aided diagnostic algorithms in terms of AUC (0.974 +/- 0.007 versus 0.890 +/- 0.008 and 0.788 +/- 0.024, respectively). The newly developed computer-aided diagnostic algorithm that used a CBCG segmentation method to measure boundaries achieved a high differentiation performance. Copyright RSNA, 2010
Computer-Aided Medical Diagnosis. Literature Review
1978-12-15
Croft found a 13% difference in diagnostic accuracy. He considered this difference insignificant in relation to the diagnostic differences caused ...type of diseases diagnosed probably are the major cause of cross-study variability in diagnostic accuracy. The consistency of diagnostic accuracy...REFERENCES ALPEROVITCH, A. and FRAGU, P., A suggestion for an effective use of a computer-aided diagnosis system in screening for hyperthyroidism , Method
A tutorial on the use of ROC analysis for computer-aided diagnostic systems.
Scheipers, Ulrich; Perrey, Christian; Siebers, Stefan; Hansen, Christian; Ermert, Helmut
2005-07-01
The application of the receiver operating characteristic (ROC) curve for computer-aided diagnostic systems is reviewed. A statistical framework is presented and different methods of evaluating the classification performance of computer-aided diagnostic systems, and, in particular, systems for ultrasonic tissue characterization, are derived. Most classifiers that are used today are dependent on a separation threshold, which can be chosen freely in many cases. The separation threshold separates the range of output values of the classification system into different target groups, thus conducting the actual classification process. In the first part of this paper, threshold specific performance measures, e.g., sensitivity and specificity, are presented. In the second part, a threshold-independent performance measure, the area under the ROC curve, is reviewed. Only the use of separation threshold-independent performance measures provides classification results that are overall representative for computer-aided diagnostic systems. The following text was motivated by the lack of a complete and definite discussion of the underlying subject in available textbooks, references and publications. Most manuscripts published so far address the theme of performance evaluation using ROC analysis in a manner too general to be practical for everyday use in the development of computer-aided diagnostic systems. Nowadays, the user of computer-aided diagnostic systems typically handles huge amounts of numerical data, not always distributed normally. Many assumptions made in more or less theoretical works on ROC analysis are no longer valid for real-life data. The paper aims at closing the gap between theoretical works and real-life data. The review provides the interested scientist with information needed to conduct ROC analysis and to integrate algorithms performing ROC analysis into classification systems while understanding the basic principles of classification.
Arunyanak, Sirikarn P; Harris, Bryan T; Grant, Gerald T; Morton, Dean; Lin, Wei-Shao
2016-07-01
This report describes a digital approach for computer-guided surgery and immediate provisionalization in a partially edentulous patient. With diagnostic data obtained from cone-beam computed tomography and intraoral digital diagnostic scans, a digital pathway of virtual diagnostic waxing, a virtual prosthetically driven surgical plan, a computer-aided design and computer-aided manufacturing (CAD/CAM) surgical template, and implant-supported screw-retained interim restorations were realized with various open-architecture CAD/CAM systems. The optional CAD/CAM diagnostic casts with planned implant placement were also additively manufactured to facilitate preoperative inspection of the surgical template and customization of the CAD/CAM-fabricated interim restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
An Instructor's Diagnostic Aid for Feedback in Training.
ERIC Educational Resources Information Center
Andrews, Dee H.; Uliano, Kevin C.
1988-01-01
Instructor's Diagnostic Aid for Feedback in Training (IDAFT) is a computer-assisted method based on error analysis, domains of learning, and events of instruction. Its use with Navy team instructors is currently being explored. (JOW)
Stapleton, Brandon M; Lin, Wei-Shao; Ntounis, Athanasios; Harris, Bryan T; Morton, Dean
2014-09-01
This clinical report demonstrated the use of an implant-supported fixed dental prosthesis fabricated with a contemporary digital approach. The digital diagnostic data acquisition was completed with a digital diagnostic impression with an intraoral scanner and cone-beam computed tomography with a prefabricated universal radiographic template to design a virtual prosthetically driven implant surgical plan. A surgical template fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) was used to perform computer-guided implant surgery. The definitive digital data were then used to design the definitive CAD/CAM-fabricated fixed dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
May, Donald M.; And Others
The minicomputer-based Computerized Diagnostic and Decision Training (CDDT) system described combines the principles of artificial intelligence, decision theory, and adaptive computer assisted instruction for training in electronic troubleshooting. The system incorporates an adaptive computer program which learns the student's diagnostic and…
ERIC Educational Resources Information Center
Stevenson, Kimberly
This master's thesis describes the development of an expert system and interactive videodisc computer-based instructional job aid used for assisting in the integration of electron beam lithography devices. Comparable to all comprehensive training, expert system and job aid development require a criterion-referenced systems approach treatment to…
Bayes' theorem application in the measure information diagnostic value assessment
NASA Astrophysics Data System (ADS)
Orzechowski, Piotr D.; Makal, Jaroslaw; Nazarkiewicz, Andrzej
2006-03-01
The paper presents Bayesian method application in the measure information diagnostic value assessment that is used in the computer-aided diagnosis system. The computer system described here has been created basing on the Bayesian Network and is used in Benign Prostatic Hyperplasia (BPH) diagnosis. The graphic diagnostic model enables to juxtapose experts' knowledge with data.
1987-06-01
to a field of research called Computer-Aided Instruction (CAI). CAI is a powerful methodology for enhancing the overall quaiity and effectiveness of...provides a very powerful tool for statistical inference, especially when pooling informations from different source is appropriate. Thus. prior...04 , 2 ’ .. ."k, + ++ ,,;-+-,..,,..v ->’,0,,.’ I The power of the model lies in its ability to adapt a diagnostic session to the level of knowledge
NASA Astrophysics Data System (ADS)
Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru
2008-03-01
Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The function to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and Success in login" effective. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.
Computer-aided diagnostic strategy selection.
Greenes, R A
1986-03-01
Determination of the optimal diagnostic work-up strategy for the patient is becoming a major concern for the practicing physician. Overlap of the indications for various diagnostic procedures, differences in their invasiveness or risk, and high costs have made physicians aware of the need to consider the choice of procedure carefully, as well as its relation to management actions available. In this article, the author discusses research approaches that aim toward development of formal decision analytic methods to allow the physician to determine optimal strategy; clinical algorithms or rules as guides to physician decisions; improved measures for characterizing the performance of diagnostic tests; educational tools for increasing the familiarity of physicians with the concepts underlying these measures and analytic procedures; and computer-based aids for facilitating the employment of these resources in actual clinical practice.
Computer-Aided Diagnosis of Acute Lymphoblastic Leukaemia
2018-01-01
Leukaemia is a form of blood cancer which affects the white blood cells and damages the bone marrow. Usually complete blood count (CBC) and bone marrow aspiration are used to diagnose the acute lymphoblastic leukaemia. It can be a fatal disease if not diagnosed at the earlier stage. In practice, manual microscopic evaluation of stained sample slide is used for diagnosis of leukaemia. But manual diagnostic methods are time-consuming, less accurate, and prone to errors due to various human factors like stress, fatigue, and so forth. Therefore, different automated systems have been proposed to wrestle the glitches in the manual diagnostic methods. In recent past, some computer-aided leukaemia diagnosis methods are presented. These automated systems are fast, reliable, and accurate as compared to manual diagnosis methods. This paper presents review of computer-aided diagnosis systems regarding their methodologies that include enhancement, segmentation, feature extraction, classification, and accuracy. PMID:29681996
NASA Astrophysics Data System (ADS)
Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou
2006-03-01
Multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information.
NASA Astrophysics Data System (ADS)
Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kakinuma, Ryutaru; Moriyama, Noriyuki
2009-02-01
Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. To overcome these problems, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The functions to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and "Success in login" effective. As a result, patients' private information is protected. We can share the screen of Web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with workstation. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.
Computer-aided diagnostic detection system of venous beading in retinal images
NASA Astrophysics Data System (ADS)
Yang, Ching-Wen; Ma, DyeJyun; Chao, ShuennChing; Wang, ChuinMu; Wen, Chia-Hsien; Lo, ChienShun; Chung, Pau-Choo; Chang, Chein-I.
2000-05-01
The detection of venous beading in retinal images provides an early sign of diabetic retinopathy and plays an important role as a preprocessing step in diagnosing ocular diseases. We present a computer-aided diagnostic system to automatically detect venous beading of blood vessels. It comprises of two modules, referred to as the blood vessel extraction module and the venus beading detection module. The former uses a bell-shaped Gaussian kernel with 12 azimuths to extract blood vessels while the latter applies a neural network-based shape cognitron to detect venous beading among the extracted blood vessels for diagnosis. Both modules are fully computer-automated. To evaluate the proposed system, 61 retinal images (32 beaded and 29 normal images) are used for performance evaluation.
Histological Image Feature Mining Reveals Emergent Diagnostic Properties for Renal Cancer
Kothari, Sonal; Phan, John H.; Young, Andrew N.; Wang, May D.
2016-01-01
Computer-aided histological image classification systems are important for making objective and timely cancer diagnostic decisions. These systems use combinations of image features that quantify a variety of image properties. Because researchers tend to validate their diagnostic systems on specific cancer endpoints, it is difficult to predict which image features will perform well given a new cancer endpoint. In this paper, we define a comprehensive set of common image features (consisting of 12 distinct feature subsets) that quantify a variety of image properties. We use a data-mining approach to determine which feature subsets and image properties emerge as part of an “optimal” diagnostic model when applied to specific cancer endpoints. Our goal is to assess the performance of such comprehensive image feature sets for application to a wide variety of diagnostic problems. We perform this study on 12 endpoints including 6 renal tumor subtype endpoints and 6 renal cancer grade endpoints. Keywords-histology, image mining, computer-aided diagnosis PMID:28163980
An evaluation of consensus techniques for diagnostic interpretation
NASA Astrophysics Data System (ADS)
Sauter, Jake N.; LaBarre, Victoria M.; Furst, Jacob D.; Raicu, Daniela S.
2018-02-01
Learning diagnostic labels from image content has been the standard in computer-aided diagnosis. Most computer-aided diagnosis systems use low-level image features extracted directly from image content to train and test machine learning classifiers for diagnostic label prediction. When the ground truth for the diagnostic labels is not available, reference truth is generated from the experts diagnostic interpretations of the image/region of interest. More specifically, when the label is uncertain, e.g. when multiple experts label an image and their interpretations are different, techniques to handle the label variability are necessary. In this paper, we compare three consensus techniques that are typically used to encode the variability in the experts labeling of the medical data: mean, median and mode, and their effects on simple classifiers that can handle deterministic labels (decision trees) and probabilistic vectors of labels (belief decision trees). Given that the NIH/NCI Lung Image Database Consortium (LIDC) data provides interpretations for lung nodules by up to four radiologists, we leverage the LIDC data to evaluate and compare these consensus approaches when creating computer-aided diagnosis systems for lung nodules. First, low-level image features of nodules are extracted and paired with their radiologists semantic ratings (1= most likely benign, , 5 = most likely malignant); second, machine learning multi-class classifiers that handle deterministic labels (decision trees) and probabilistic vectors of labels (belief decision trees) are built to predict the lung nodules semantic ratings. We show that the mean-based consensus generates the most robust classi- fier overall when compared to the median- and mode-based consensus. Lastly, the results of this study show that, when building CAD systems with uncertain diagnostic interpretation, it is important to evaluate different strategies for encoding and predicting the diagnostic label.
Cone Beam Computed Tomography-Dawn of A New Imaging Modality in Orthodontics
Mamatha, J; Chaitra, K R; Paul, Renji K; George, Merin; Anitha, J; Khanna, Bharti
2015-01-01
Today, we are in a world of innovations, and there are various diagnostics aids that help to take a decision regarding treatment in a well-planned way. Cone beam computed tomography (CBCT) has been a vital tool for imaging diagnostic tool in orthodontics. This article reviews case reports during orthodontic treatment and importance of CBCT during the treatment evaluation. PMID:26225116
Computer-Aided Diagnostic System For Mass Survey Chest Images
NASA Astrophysics Data System (ADS)
Yasuda, Yoshizumi; Kinoshita, Yasuhiro; Emori, Yasufumi; Yoshimura, Hitoshi
1988-06-01
In order to support screening of chest radiographs on mass survey, a computer-aided diagnostic system that automatically detects abnormality of candidate images using a digital image analysis technique has been developed. Extracting boundary lines of lung fields and examining their shapes allowed various kind of abnormalities to be detected. Correction and expansion were facilitated by describing the system control, image analysis control and judgement of abnormality in the rule type programing language. In the experiments using typical samples of student's radiograms, good results were obtained for the detection of abnormal shape of lung field, cardiac hypertrophy and scoliosis. As for the detection of diaphragmatic abnormality, relatively good results were obtained but further improvements will be necessary.
Evaluation of computer-aided detection and diagnosis systems.
Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping
2013-08-01
Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and "best practices" for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in clinical practice.
Evaluation of computer-aided detection and diagnosis systemsa)
Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G.; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T.; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M.; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping
2013-01-01
Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and “best practices” for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in clinical practice. PMID:23927365
Cupek, Rafal; Ziębiński, Adam
2016-01-01
Rheumatoid arthritis is the most common rheumatic disease with arthritis, and causes substantial functional disability in approximately 50% patients after 10 years. Accurate measurement of the disease activity is crucial to provide an adequate treatment and care to the patients. The aim of this study is focused on a computer aided diagnostic system that supports an assessment of synovitis severity. This paper focus on a computer aided diagnostic system that was developed within joint Polish-Norwegian research project related to the automated assessment of the severity of synovitis. Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Synovitis is estimated by ultrasound examiner using the scoring system graded from 0 to 3. Activity score is estimated on the basis of the examiner's experience or standardized ultrasound atlases. The method needs trained medical personnel and the result can be affected by a human error. The porotype of a computer-aided diagnostic system and algorithms essential for an analysis of ultrasonic images of finger joints are main scientific output of the MEDUSA project. Medusa Evaluation System prototype uses bone, skin, joint and synovitis area detectors for mutual structural model based evaluation of synovitis. Finally, several algorithms that support the semi-automatic or automatic detection of the bone region were prepared as well as a system that uses the statistical data processing approach in order to automatically localize the regions of interest. Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Activity score is estimated on the basis of the examiner's experience and the result can be affected by a human error. In this paper we presented the MEDUSA project which is focused on a computer aided diagnostic system that supports an assessment of synovitis severity.
The future of medical diagnostics: large digitized databases.
Kerr, Wesley T; Lau, Edward P; Owens, Gwen E; Trefler, Aaron
2012-09-01
The electronic health record mandate within the American Recovery and Reinvestment Act of 2009 will have a far-reaching affect on medicine. In this article, we provide an in-depth analysis of how this mandate is expected to stimulate the production of large-scale, digitized databases of patient information. There is evidence to suggest that millions of patients and the National Institutes of Health will fully support the mining of such databases to better understand the process of diagnosing patients. This data mining likely will reaffirm and quantify known risk factors for many diagnoses. This quantification may be leveraged to further develop computer-aided diagnostic tools that weigh risk factors and provide decision support for health care providers. We expect that creation of these databases will stimulate the development of computer-aided diagnostic support tools that will become an integral part of modern medicine.
Computer-aided dermoscopy for diagnosis of melanoma
Barzegari, Masoomeh; Ghaninezhad, Haiedeh; Mansoori, Parisa; Taheri, Arash; Naraghi, Zahra S; Asgari, Masood
2005-01-01
Background Computer-aided dermoscopy using artificial neural networks has been reported to be an accurate tool for the evaluation of pigmented skin lesions. We set out to determine the sensitivity and specificity of a computer-aided dermoscopy system for diagnosis of melanoma in Iranian patients. Methods We studied 122 pigmented skin lesions which were referred for diagnostic evaluation or cosmetic reasons. Each lesion was examined by two clinicians with naked eyes and all of their clinical diagnostic considerations were recorded. The lesions were analyzed using a microDERM® dermoscopy unit. The output value of the software for each lesion was a score between 0 and 10. All of the lesions were excised and examined histologically. Results Histopathological examination revealed melanoma in six lesions. Considering only the most likely clinical diagnosis, sensitivity and specificity of clinical examination for diagnosis of melanoma were 83% and 96%, respectively. Considering all clinical diagnostic considerations, the sensitivity and specificity were 100% and 89%. Choosing a cut-off point of 7.88 for dermoscopy score, the sensitivity and specificity of the score for diagnosis of melanoma were 83% and 96%, respectively. Setting the cut-off point at 7.34, the sensitivity and specificity were 100% and 90%. Conclusion The diagnostic accuracy of the dermoscopy system was at the level of clinical examination by dermatologists with naked eyes. This system may represent a useful tool for screening of melanoma, particularly at centers not experienced in the field of pigmented skin lesions. PMID:16000171
Enhancements in medicine by integrating content based image retrieval in computer-aided diagnosis
NASA Astrophysics Data System (ADS)
Aggarwal, Preeti; Sardana, H. K.
2010-02-01
Computer-aided diagnosis (CAD) has become one of the major research subjects in medical imaging and diagnostic radiology. With cad, radiologists use the computer output as a "second opinion" and make the final decisions. Retrieving images is a useful tool to help radiologist to check medical image and diagnosis. The impact of contentbased access to medical images is frequently reported but existing systems are designed for only a particular context of diagnosis. The challenge in medical informatics is to develop tools for analyzing the content of medical images and to represent them in a way that can be efficiently searched and compared by the physicians. CAD is a concept established by taking into account equally the roles of physicians and computers. To build a successful computer aided diagnostic system, all the relevant technologies, especially retrieval need to be integrated in such a manner that should provide effective and efficient pre-diagnosed cases with proven pathology for the current case at the right time. In this paper, it is suggested that integration of content-based image retrieval (CBIR) in cad can bring enormous results in medicine especially in diagnosis. This approach is also compared with other approaches by highlighting its advantages over those approaches.
Bayesian networks and statistical analysis application to analyze the diagnostic test accuracy
NASA Astrophysics Data System (ADS)
Orzechowski, P.; Makal, Jaroslaw; Onisko, A.
2005-02-01
The computer aided BPH diagnosis system based on Bayesian network is described in the paper. First result are compared to a given statistical method. Different statistical methods are used successfully in medicine for years. However, the undoubted advantages of probabilistic methods make them useful in application in newly created systems which are frequent in medicine, but do not have full and competent knowledge. The article presents advantages of the computer aided BPH diagnosis system in clinical practice for urologists.
Computer-aided testing of pilot response to critical in-flight events
NASA Technical Reports Server (NTRS)
Giffin, W. C.; Rockwell, T. H.
1984-01-01
This research on pilot response to critical in-flight events employs a unique methodology including an interactive computer-aided scenario-testing system. Navigation displays, instrument-panel displays, and assorted textual material are presented on a touch-sensitive CRT screen. Problem diagnosis scenarios, destination-diversion scenarios and combined destination/diagnostic tests are available. A complete time history of all data inquiries and responses is maintained. Sample results of diagnosis scenarios obtained from testing 38 licensed pilots are presented and discussed.
Enormous knowledge base of disease diagnosis criteria.
Xiao, Z H; Xiao, Y H; Pei, J H
1995-01-01
One of the problems in the development of the medical knowledge systems is the limitations of the system's knowledge. It is a common expectation to increase the number of diseases contained in a system. Using a high density knowledge representation method designed by us, we have developed the Enormous Knowledge Base of Disease Diagnosis Criteria (EKBDDC). It contains diagnostic criteria of 1,001 diagnostic entities and describes nearly 4,000 items of diagnostic indicators. It is the core of a huge medical project--the Electronic-Brain Medical Erudite (EBME). This enormous knowledge base was implemented initially on a low-cost popular microcomputer, which can aid in the prompting of typical disease and in teaching of diagnosis. The knowledge base is easy to expand. One of the main goals of EKBDDC is to increase the number of diseases included in it as far as possible using a low-cost computer with a comparatively small storage capacity. For this, we have designed a high density knowledge representation method. Criteria of various diagnostic entities are respectively stored in different records of the knowledge base. Each diagnostic entity corresponds to a diagnostic criterion data set; each data set consists of some diagnostic criterion data values (Table 1); each data is composed of two parts: integer and decimal; the integral part is the coding number of the given diagnostic information, and the decimal part is the diagnostic value of this information to the disease indicated by corresponding record number. For example, 75.02: the integer 75 is the coding number of "hemorrhagic skin rash"; the decimal 0.02 is the diagnostic value of this manifestation for diagnosing allergic purpura. TABULAR DATA, SEE PUBLISHED ABSTRACT. The algebraic sum method, a special form of the weighted summation, is adopted as mathematical model. In EKBDDC, the diagnostic values, which represent the significance of the disease manifestations for diagnosing corresponding diseases, were determined empirically. It is of a great economical, practical, and technical significance to realize enormous knowledge bases of disease diagnosis criteria on a low-cost popular microcomputer. This is beneficial for the developing countries to popularize medical informatics. To create the enormous international computer-aided diagnosis system, one may jointly develop the unified modules of disease diagnosis criteria used to "inlay" relevant computer-aided diagnosis systems. It is just like assembling a house using prefabricated panels.
NASA Astrophysics Data System (ADS)
Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kaneko, Masahiro; Kakinuma, Ryutaro; Moriyama, Noriyuki
2010-03-01
Diagnostic MDCT imaging requires a considerable number of images to be read. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. Because of such a background, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis. We also have developed the teleradiology network system by using web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. Our teleradiology network system can perform Web medical image conference in the medical institutions of a remote place using the web medical image conference system. We completed the basic proof experiment of the web medical image conference system with information security solution. We can share the screen of web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with the workstation that builds in some diagnostic assistance methods. Biometric face authentication used on site of teleradiology makes "Encryption of file" and "Success in login" effective. Our Privacy and information security technology of information security solution ensures compliance with Japanese regulations. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new teleradiology network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our teleradiology network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.
Krause, C; Ens, K; Fechner, K; Voigt, J; Fraune, J; Rohwäder, E; Hahn, M; Danckwardt, M; Feirer, C; Barth, E; Martinetz, T; Stöcker, W
2015-04-01
Antinuclear autoantibodies (ANA) are highly informative biomarkers in autoimmune diagnostics. The increasing demand for effective test systems, however, has led to the development of a confusingly large variety of different platforms. One of them, the indirect immunofluorescence (IIF), is regarded as the common gold standard for ANA screening, as described in a position statement by the American College of Rheumatology in 2009. Technological solutions have been developed aimed at standardization and automation of IIF to overcome methodological limitations and subjective bias in IIF interpretation. In this review, we present the EUROPattern Suite, a system for computer-aided immunofluorescence microscopy (CAIFM) including automated acquisition of digital images and evaluation of IIF results. The system was originally designed for ANA diagnostics on human epithelial cells, but its applications have been extended with the latest system update version 1.5 to the analysis of antineutrophil cytoplasmic antibodies (ANCA) and anti-dsDNA antibodies. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Tomar, Deepak; Dhingra, Anil; Tomer, Anil; Sharma, Shalini; Sharma, Vivek; Miglani, Anjali
2013-05-01
Aberrant root canal anatomy is diagnostically and clinically challenging for clinicians. The most common root canal configuration of human molars is 2 roots and 3 canals, but various combinations may still exist. Third molars are known to have the most unusual anatomy among human teeth. Restorative, prosthetic, and orthodontic considerations often require endodontic treatment of third molars in order for them to be retained as functional components of the dental arch. The present case report demonstrates unusual root canal morphology of the mandibular third molar. Roentgenographic examination, which included spiral CT scan, revealed 3 separate mesial roots in tooth #48 with 3 independent canals and 3 canal orifices, indicating an endodontic rarity. The present case report puts impetus on exploration of additional canals using advanced diagnostic aids, such as spiral computed tomography, which can have a huge impact on the successful outcome of endodontic therapy. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Rockwell, T. H.; Giffin, W. C.
1982-01-01
Computer displays using PLATO are illustrated. Diagnostic scenarios are described. A sample of subject data is presented. Destination diversion displays, a combined destination, diversion scenario, and critical in-flight event (CIFE) data collection/subject testing system are presented.
Computed tomography as a diagnostic aid for extracanal invasive resorption.
Kim, Euiseong; Kim, Kee-Deog; Roh, Byoung-Duck; Cho, Yong-Sik; Lee, Seung-Jong
2003-07-01
A case of multiple extracanal invasive resorption is reported. The patient had a history of hypothyroidism for approximately 1 yr before the dental visit. Utilization of computed tomography and a rapid prototyping tooth model in diagnosing the exact location and the size of the resorption area are discussed.
Computer-assisted education and interdisciplinary breast cancer diagnosis
NASA Astrophysics Data System (ADS)
Whatmough, Pamela; Gale, Alastair G.; Wilson, A. R. M.
1996-04-01
The diagnosis of breast disease for screening or symptomatic women is largely arrived at by a multi-disciplinary team. We report work on the development and assessment of an inter- disciplinary computer based learning system to support the diagnosis of this disease. The diagnostic process is first modelled from different viewpoints and then appropriate knowledge structures pertinent to the domains of radiologist, pathologist and surgeon are depicted. Initially the underlying inter-relationships of the mammographic diagnostic approach were detailed which is largely considered here. Ultimately a system is envisaged which will link these specialties and act as a diagnostic aid as well as a multi-media educational system.
Computer Aided Diagnostic Support System for Skin Cancer: A Review of Techniques and Algorithms
Masood, Ammara; Al-Jumaily, Adel Ali
2013-01-01
Image-based computer aided diagnosis systems have significant potential for screening and early detection of malignant melanoma. We review the state of the art in these systems and examine current practices, problems, and prospects of image acquisition, pre-processing, segmentation, feature extraction and selection, and classification of dermoscopic images. This paper reports statistics and results from the most important implementations reported to date. We compared the performance of several classifiers specifically developed for skin lesion diagnosis and discussed the corresponding findings. Whenever available, indication of various conditions that affect the technique's performance is reported. We suggest a framework for comparative assessment of skin cancer diagnostic models and review the results based on these models. The deficiencies in some of the existing studies are highlighted and suggestions for future research are provided. PMID:24575126
On the convergence of nanotechnology and Big Data analysis for computer-aided diagnosis.
Rodrigues, Jose F; Paulovich, Fernando V; de Oliveira, Maria Cf; de Oliveira, Osvaldo N
2016-04-01
An overview is provided of the challenges involved in building computer-aided diagnosis systems capable of precise medical diagnostics based on integration and interpretation of data from different sources and formats. The availability of massive amounts of data and computational methods associated with the Big Data paradigm has brought hope that such systems may soon be available in routine clinical practices, which is not the case today. We focus on visual and machine learning analysis of medical data acquired with varied nanotech-based techniques and on methods for Big Data infrastructure. Because diagnosis is essentially a classification task, we address the machine learning techniques with supervised and unsupervised classification, making a critical assessment of the progress already made in the medical field and the prospects for the near future. We also advocate that successful computer-aided diagnosis requires a merge of methods and concepts from nanotechnology and Big Data analysis.
NASA Astrophysics Data System (ADS)
Mostapha, Mahmoud; Khalifa, Fahmi; Alansary, Amir; Soliman, Ahmed; Gimel'farb, Georgy; El-Baz, Ayman
2013-10-01
Early detection of renal transplant rejection is important to implement appropriate medical and immune therapy in patients with transplanted kidneys. In literature, a large number of computer-aided diagnostic (CAD) systems using different image modalities, such as ultrasound (US), magnetic resonance imaging (MRI), computed tomography (CT), and radionuclide imaging, have been proposed for early detection of kidney diseases. A typical CAD system for kidney diagnosis consists of a set of processing steps including: motion correction, segmentation of the kidney and/or its internal structures (e.g., cortex, medulla), construction of agent kinetic curves, functional parameter estimation, diagnosis, and assessment of the kidney status. In this paper, we survey the current state-of-the-art CAD systems that have been developed for kidney disease diagnosis using dynamic MRI. In addition, the paper addresses several challenges that researchers face in developing efficient, fast and reliable CAD systems for the early detection of kidney diseases.
Deep Learning Role in Early Diagnosis of Prostate Cancer
Reda, Islam; Khalil, Ashraf; Elmogy, Mohammed; Abou El-Fetouh, Ahmed; Shalaby, Ahmed; Abou El-Ghar, Mohamed; Elmaghraby, Adel; Ghazal, Mohammed; El-Baz, Ayman
2018-01-01
The objective of this work is to develop a computer-aided diagnostic system for early diagnosis of prostate cancer. The presented system integrates both clinical biomarkers (prostate-specific antigen) and extracted features from diffusion-weighted magnetic resonance imaging collected at multiple b values. The presented system performs 3 major processing steps. First, prostate delineation using a hybrid approach that combines a level-set model with nonnegative matrix factorization. Second, estimation and normalization of diffusion parameters, which are the apparent diffusion coefficients of the delineated prostate volumes at different b values followed by refinement of those apparent diffusion coefficients using a generalized Gaussian Markov random field model. Then, construction of the cumulative distribution functions of the processed apparent diffusion coefficients at multiple b values. In parallel, a K-nearest neighbor classifier is employed to transform the prostate-specific antigen results into diagnostic probabilities. Finally, those prostate-specific antigen–based probabilities are integrated with the initial diagnostic probabilities obtained using stacked nonnegativity constraint sparse autoencoders that employ apparent diffusion coefficient–cumulative distribution functions for better diagnostic accuracy. Experiments conducted on 18 diffusion-weighted magnetic resonance imaging data sets achieved 94.4% diagnosis accuracy (sensitivity = 88.9% and specificity = 100%), which indicate the promising results of the presented computer-aided diagnostic system. PMID:29804518
Integrated Artificial Intelligence Approaches for Disease Diagnostics.
Vashistha, Rajat; Chhabra, Deepak; Shukla, Pratyoosh
2018-06-01
Mechanocomputational techniques in conjunction with artificial intelligence (AI) are revolutionizing the interpretations of the crucial information from the medical data and converting it into optimized and organized information for diagnostics. It is possible due to valuable perfection in artificial intelligence, computer aided diagnostics, virtual assistant, robotic surgery, augmented reality and genome editing (based on AI) technologies. Such techniques are serving as the products for diagnosing emerging microbial or non microbial diseases. This article represents a combinatory approach of using such approaches and providing therapeutic solutions towards utilizing these techniques in disease diagnostics.
The microcomputer in the dental office: a new diagnostic aid.
van der Stelt, P F
1985-06-01
The first computer applications in the dental office were based upon standard accountancy procedures. Recently, more and more computer applications have become available to meet the specific requirements of dental practice. This implies not only business procedures, but also facilities to store patient records in the system and retrieve them easily. Another development concerns the automatic calculation of diagnostic data such as those provided in cephalometric analysis. Furthermore, growth and surgical results in the craniofacial area can be predicted by computerized extrapolation. Computers have been useful in obtaining the patient's anamnestic data objectively and for the making of decisions based on such data. Computer-aided instruction systems have been developed for undergraduate students to bridge the gap between textbook and patient interaction without the risks inherent in the latter. Radiology will undergo substantial changes as a result of the application of electronic imaging devices instead of the conventional radiographic films. Computer-assisted electronic imaging will enable image processing, image enhancement, pattern recognition and data transmission for consultation and storage purposes. Image processing techniques will increase image quality whilst still allowing low-dose systems. Standardization of software and system configuration and the development of 'user friendly' programs is the major concern for the near future.
NASA Astrophysics Data System (ADS)
Beiden, Sergey V.; Wagner, Robert F.; Campbell, Gregory; Metz, Charles E.; Chan, Heang-Ping; Nishikawa, Robert M.; Schnall, Mitchell D.; Jiang, Yulei
2001-06-01
In recent years, the multiple-reader, multiple-case (MRMC) study paradigm has become widespread for receiver operating characteristic (ROC) assessment of systems for diagnostic imaging and computer-aided diagnosis. We review how MRMC data can be analyzed in terms of the multiple components of the variance (case, reader, interactions) observed in those studies. Such information is useful for the design of pivotal studies from results of a pilot study and also for studying the effects of reader training. Recently, several of the present authors have demonstrated methods to generalize the analysis of multiple variance components to the case where unaided readers of diagnostic images are compared with readers who receive the benefit of a computer assist (CAD). For this case it is necessary to model the possibility that several of the components of variance might be reduced when readers incorporate the computer assist, compared to the unaided reading condition. We review results of this kind of analysis on three previously published MRMC studies, two of which were applications of CAD to diagnostic mammography and one was an application of CAD to screening mammography. The results for the three cases are seen to differ, depending on the reader population sampled and the task of interest. Thus, it is not possible to generalize a particular analysis of variance components beyond the tasks and populations actually investigated.
ERIC Educational Resources Information Center
Hopf-Weichel, Rosemarie; And Others
This report describes results of the first year of a three-year program to develop and evaluate a new Adaptive Computerized Training System (ACTS) for electronics maintenance training. (ACTS incorporates an adaptive computer program that learns the student's diagnostic and decision value structure, compares it to that of an expert, and adapts the…
NASA Astrophysics Data System (ADS)
Vilagosh, Zoltan; Lajevardipour, Alireza; Wood, Andrew
2018-01-01
Finite-difference time-domain (FDTD) computational phantoms aid the analysis of THz radiation interaction with human skin. The presented computational phantoms have accurate anatomical layering and electromagnetic properties. A novel "large sheet" simulation technique is used allowing for a realistic representation of lateral absorption and reflection of in-vivo measurements. Simulations carried out to date have indicated that hair follicles act as THz propagation channels and confirms the possible role of melanin, both in nevi and skin pigmentation, to act as a significant absorber of THz radiation. A novel freezing technique has promise in increasing the depth of skin penetration of THz radiation to aid diagnostic imaging.
A Computer-Aided Distinction Method of Borderline Grades of Oral Cancer
NASA Astrophysics Data System (ADS)
Sami, Mustafa M.; Saito, Masahisa; Muramatsu, Shogo; Kikuchi, Hisakazu; Saku, Takashi
We have developed a new computer-aided diagnostic system for differentiating oral borderline malignancies in hematoxylin-eosin stained microscopic images. Epithelial dysplasia and carcinoma in-situ (CIS) of oral mucosa are two different borderline grades similar to each other, and it is difficult to distinguish between them. A new image processing and analysis method has been applied to a variety of histopathological features and shows the possibility for differentiating the oral cancer borderline grades automatically. The method is based on comparing the drop-shape similarity level in a particular manually selected pair of neighboring rete ridges. It was found that the considered similarity level in dysplasia was higher than those in epithelial CIS, of which pathological diagnoses were conventionally made by pathologists. The developed image processing method showed a good promise for the computer-aided pathological assessment of oral borderline malignancy differentiation in clinical practice.
NASA Technical Reports Server (NTRS)
Rockwell, T. H.; Giffin, W. C.; Romer, D. J.
1984-01-01
Rockwell and Giffin (1982) and Giffin and Rockwell (1983) have discussed the use of computer aided testing (CAT) in the study of pilot response to critical in-flight events. The present investigation represents an extension of these earlier studies. In testing pilot responses to critical in-flight events, use is made of a Plato-touch CRT system operating on a menu based format. In connection with the typical diagnostic problem, the pilot was presented with symptoms within a flight scenario. In one problem, the pilot has four minutes for obtaining the information which is needed to make a diagnosis of the problem. In the reported research, the attempt has been made to combine both diagnosis and diversion scenario into a single computer aided test. Tests with nine subjects were conducted. The obtained results and their significance are discussed.
Oloumi, Faraz; Rangayyan, Rangaraj M.; Ells, Anna L.
2016-01-01
Abstract. Retinopathy of prematurity (ROP), a disorder of the retina occurring in preterm infants, is the leading cause of preventable childhood blindness. An active phase of ROP that requires treatment is associated with the presence of plus disease, which is diagnosed clinically in a qualitative manner by visual assessment of the existence of a certain level of increase in the thickness and tortuosity of retinal vessels. The present study performs computer-aided diagnosis (CAD) of plus disease via quantitative measurement of tortuosity in retinal fundus images of preterm infants. Digital image processing techniques were developed for the detection of retinal vessels and measurement of their tortuosity. The total lengths of abnormally tortuous vessels in each quadrant and the entire image were then computed. A minimum-length diagnostic-decision-making criterion was developed to assess the diagnostic sensitivity and specificity of the values obtained. The area (Az) under the receiver operating characteristic curve was used to assess the overall diagnostic accuracy of the methods. Using a set of 19 retinal fundus images of preterm infants with plus disease and 91 without plus disease, the proposed methods provided an overall diagnostic accuracy of Az=0.98. Using the total length of all abnormally tortuous vessel segments in an image, our techniques are capable of CAD of plus disease with high accuracy without the need for manual selection of vessels to analyze. The proposed methods may be used in a clinical or teleophthalmological setting. PMID:28018938
Foley, Finbar; Rajagopalan, Srinivasan; Raghunath, Sushravya M; Boland, Jennifer M; Karwoski, Ronald A; Maldonado, Fabien; Bartholmai, Brian J; Peikert, Tobias
2016-01-01
Increased clinical use of chest high-resolution computed tomography results in increased identification of lung adenocarcinomas and persistent subsolid opacities. However, these lesions range from very indolent to extremely aggressive tumors. Clinically relevant diagnostic tools to noninvasively risk stratify and guide individualized management of these lesions are lacking. Research efforts investigating semiquantitative measures to decrease interrater and intrarater variability are emerging, and in some cases steps have been taken to automate this process. However, many such methods currently are still suboptimal, require validation and are not yet clinically applicable. The computer-aided nodule assessment and risk yield software application represents a validated tool for the automated, quantitative, and noninvasive tool for risk stratification of adenocarcinoma lung nodules. Computer-aided nodule assessment and risk yield correlates well with consensus histology and postsurgical patient outcomes, and therefore may help to guide individualized patient management, for example, in identification of nodules amenable to radiological surveillance, or in need of adjunctive therapy. Copyright © 2016 Elsevier Inc. All rights reserved.
A computer-aided ECG diagnostic tool.
Oweis, Rami; Hijazi, Lily
2006-03-01
Jordan lacks companies that provide local medical facilities with products that are of help in daily performed medical procedures. Because of this, the country imports most of these expensive products. Consequently, a local interest in producing such products has emerged and resulted in serious research efforts in this area. The main goal of this paper is to provide local (the north of Jordan) clinics with a computer-aided electrocardiogram (ECG) diagnostic tool in an attempt to reduce time and work demands for busy physicians especially in areas where only one general medicine doctor is employed and a bulk of cases are to be diagnosed. The tool was designed to help in detecting heart defects such as arrhythmias and heart blocks using ECG signal analysis depending on the time-domain representation, the frequency-domain spectrum, and the relationship between them. The application studied here represents a state of the art ECG diagnostic tool that was designed, implemented, and tested in Jordan to serve wide spectrum of population who are from poor families. The results of applying the tool on randomly selected representative sample showed about 99% matching with those results obtained at specialized medical facilities. Costs, ease of interface, and accuracy indicated the usefulness of the tool and its use as an assisting diagnostic tool.
[The possibility of using a laser stereolithography method in forensic medicine].
Abramov, S S; Boldyrev, N N; Evseev, A V; Kotsiuba, E V; Novikov, M M; Panchenko, V Ia; Semeshin, N M; Iakunin, V P
1998-01-01
The data of computer-aided tomography are proposed to be used in forensic medical diagnostic and identification studies. The technology of making hard copies of objects by laser stereolithography on the basis of tomography data is described.
Deep-reasoning fault diagnosis - An aid and a model
NASA Technical Reports Server (NTRS)
Yoon, Wan Chul; Hammer, John M.
1988-01-01
The design and evaluation are presented for the knowledge-based assistance of a human operator who must diagnose a novel fault in a dynamic, physical system. A computer aid based on a qualitative model of the system was built to help the operators overcome some of their cognitive limitations. This aid differs from most expert systems in that it operates at several levels of interaction that are believed to be more suitable for deep reasoning. Four aiding approaches, each of which provided unique information to the operator, were evaluated. The aiding features were designed to help the human's casual reasoning about the system in predicting normal system behavior (N aiding), integrating observations into actual system behavior (O aiding), finding discrepancies between the two (O-N aiding), or finding discrepancies between observed behavior and hypothetical behavior (O-HN aiding). Human diagnostic performance was found to improve by almost a factor of two with O aiding and O-N aiding.
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, Joshua J.; Taplin, Stephen H.; Carney, Patricia A.; Abraham, Linn; Sickles, Edward A.; D'Orsi, Carl; Berns, Eric A.; Cutter, Gary; Hendrick, R. Edward; Barlow, William E.; Elmore, Joann G.
2011-01-01
Background Computer-aided detection identifies suspicious findings on mammograms to assist radiologists. Since the Food and Drug Administration approved the technology in 1998, it has been disseminated into practice, but its effect on the accuracy of interpretation is unclear. Methods We determined the association between the use of computer-aided detection at mammography facilities and the performance of screening mammography from 1998 through 2002 at 43 facilities in three states. We had complete data for 222,135 women (a total of 429,345 mammograms), including 2351 women who received a diagnosis of breast cancer within 1 year after screening. We calculated the specificity, sensitivity, and positive predictive value of screening mammography with and without computer-aided detection, as well as the rates of biopsy and breast-cancer detection and the overall accuracy, measured as the area under the receiver-operating-characteristic (ROC) curve. Results Seven facilities (16%) implemented computer-aided detection during the study period. Diagnostic specificity decreased from 90.2% before implementation to 87.2% after implementation (P<0.001), the positive predictive value decreased from 4.1% to 3.2% (P = 0.01), and the rate of biopsy increased by 19.7% (P<0.001). The increase in sensitivity from 80.4% before implementation of computer-aided detection to 84.0% after implementation was not significant (P = 0.32). The change in the cancer-detection rate (including invasive breast cancers and ductal carcinomas in situ) was not significant (4.15 cases per 1000 screening mammograms before implementation and 4.20 cases after implementation, P = 0.90). Analyses of data from all 43 facilities showed that the use of computer-aided detection was associated with significantly lower overall accuracy than was nonuse (area under the ROC curve, 0.871 vs. 0.919; P = 0.005). Conclusions The use of computer-aided detection is associated with reduced accuracy of interpretation of screening mammograms. The increased rate of biopsy with the use of computer-aided detection is not clearly associated with improved detection of invasive breast cancer. PMID:17409321
Levman, Jacob E D; Gallego-Ortiz, Cristina; Warner, Ellen; Causer, Petrina; Martel, Anne L
2016-02-01
Magnetic resonance imaging (MRI)-enabled cancer screening has been shown to be a highly sensitive method for the early detection of breast cancer. Computer-aided detection systems have the potential to improve the screening process by standardizing radiologists to a high level of diagnostic accuracy. This retrospective study was approved by the institutional review board of Sunnybrook Health Sciences Centre. This study compares the performance of a proposed method for computer-aided detection (based on the second-order spatial derivative of the relative signal intensity) with the signal enhancement ratio (SER) on MRI-based breast screening examinations. Comparison is performed using receiver operating characteristic (ROC) curve analysis as well as free-response receiver operating characteristic (FROC) curve analysis. A modified computer-aided detection system combining the proposed approach with the SER method is also presented. The proposed method provides improvements in the rates of false positive markings over the SER method in the detection of breast cancer (as assessed by FROC analysis). The modified computer-aided detection system that incorporates both the proposed method and the SER method yields ROC results equal to that produced by SER while simultaneously providing improvements over the SER method in terms of false positives per noncancerous exam. The proposed method for identifying malignancies outperforms the SER method in terms of false positives on a challenging dataset containing many small lesions and may play a useful role in breast cancer screening by MRI as part of a computer-aided detection system.
Object oriented fault diagnosis system for space shuttle main engine redlines
NASA Technical Reports Server (NTRS)
Rogers, John S.; Mohapatra, Saroj Kumar
1990-01-01
A great deal of attention has recently been given to Artificial Intelligence research in the area of computer aided diagnostics. Due to the dynamic and complex nature of space shuttle red-line parameters, a research effort is under way to develop a real time diagnostic tool that will employ historical and engineering rulebases as well as a sensor validity checking. The capability of AI software development tools (KEE and G2) will be explored by applying object oriented programming techniques in accomplishing the diagnostic evaluation.
Computer-aided diagnosis of HIE based on segmentation of MRI
NASA Astrophysics Data System (ADS)
Sun, Ziguang; Li, Chungui; Wang, Qin
2009-10-01
Computer-aided diagnosis has become one of the major research subjects in medical imaging and diagnostic radiology. Hypoxic-ischemic encephalopathy (HIE), remains a serious condition that causes significant mortality and long-term morbidity to neonates. We adopt self-organizing feature maps to segment the tissues, such as white matter and grey matter in the magnetic resonance images. The borderline between white matter and grey matter can be found and the doubtful regions along with the borderline can be localized, then the feature in doubtful regions can be quantified. The method can assist doctors to easily diagnose whether a neonate is ill with mild HIE.
On the diagnostic emulation technique and its use in the AIRLAB
NASA Technical Reports Server (NTRS)
Migneault, Gerard E.
1988-01-01
An aid is presented for understanding and judging the relevance of the diagnostic emulation technique to studies of highly reliable, digital computing systems for aircraft. A short review is presented of the need for and the use of the technique as well as an explanation of its principles of operation and implementation. Details that would be needed for operational control or modification of existing versions of the technique are not described.
"Tennis elbow". A challenging call for computation and medicine
NASA Astrophysics Data System (ADS)
Sfetsioris, D.; Bontioti, E. N.
2014-10-01
An attempt to give an insight on the features composing this musculotendinous disorder. We address the issues of definition, pathophysiology and the mechanism underlying the onset and the occurrence of the disease, diagnosis and diagnostic tools as well as the methods of treatment. We focus mostly on conservative treatment protocols and we recognize the need for a more thorough investigation with the aid of computation.
Acharya, U Rajendra; Sree, S Vinitha; Krishnan, M Muthu Rama; Molinari, Filippo; Zieleźnik, Witold; Bardales, Ricardo H; Witkowska, Agnieszka; Suri, Jasjit S
2014-02-01
Computer-aided diagnostic (CAD) techniques aid physicians in better diagnosis of diseases by extracting objective and accurate diagnostic information from medical data. Hashimoto thyroiditis is the most common type of inflammation of the thyroid gland. The inflammation changes the structure of the thyroid tissue, and these changes are reflected as echogenic changes on ultrasound images. In this work, we propose a novel CAD system (a class of systems called ThyroScan) that extracts textural features from a thyroid sonogram and uses them to aid in the detection of Hashimoto thyroiditis. In this paradigm, we extracted grayscale features based on stationary wavelet transform from 232 normal and 294 Hashimoto thyroiditis-affected thyroid ultrasound images obtained from a Polish population. Significant features were selected using a Student t test. The resulting feature vectors were used to build and evaluate the following 4 classifiers using a 10-fold stratified cross-validation technique: support vector machine, decision tree, fuzzy classifier, and K-nearest neighbor. Using 7 significant features that characterized the textural changes in the images, the fuzzy classifier had the highest classification accuracy of 84.6%, sensitivity of 82.8%, specificity of 87.0%, and a positive predictive value of 88.9%. The proposed ThyroScan CAD system uses novel features to noninvasively detect the presence of Hashimoto thyroiditis on ultrasound images. Compared to manual interpretations of ultrasound images, the CAD system offers a more objective interpretation of the nature of the thyroid. The preliminary results presented in this work indicate the possibility of using such a CAD system in a clinical setting after evaluating it with larger databases in multicenter clinical trials.
Faultfinder: A diagnostic expert system with graceful degradation for onboard aircraft applications
NASA Technical Reports Server (NTRS)
Abbott, Kathy H.; Schutte, Paul C.; Palmer, Michael T.; Ricks, Wendell R.
1988-01-01
A research effort was conducted to explore the application of artificial intelligence technology to automation of fault monitoring and diagnosis as an aid to the flight crew. Human diagnostic reasoning was analyzed and actual accident and incident cases were reconstructed. Based on this analysis and reconstruction, diagnostic concepts were conceived and implemented for an aircraft's engine and hydraulic subsystems. These concepts are embedded within a multistage approach to diagnosis that reasons about time-based, causal, and qualitative information, and enables a certain amount of graceful degradation. The diagnostic concepts are implemented in a computer program called Faultfinder that serves as a research prototype.
Li, Feng
2015-07-01
This review paper is based on our research experience in the past 30 years. The importance of radiologists' role is discussed in the development or evaluation of new medical images and of computer-aided detection (CAD) schemes in chest radiology. The four main topics include (1) introducing what diseases can be included in a research database for different imaging techniques or CAD systems and what imaging database can be built by radiologists, (2) understanding how radiologists' subjective judgment can be combined with technical objective features to improve CAD performance, (3) sharing our experience in the design of successful observer performance studies, and (4) finally, discussing whether the new images and CAD systems can improve radiologists' diagnostic ability in chest radiology. In conclusion, advanced imaging techniques and detection/classification of CAD systems have a potential clinical impact on improvement of radiologists' diagnostic ability, for both the detection and the differential diagnosis of various lung diseases, in chest radiology.
Kamble, Amit Pralhad; Pawar, Rohini Rangarao; Mattigatti, Sudha; Mangala, T. M.; Makandar, Saleem
2017-01-01
The purpose of these case reports is to emphasize the importance of knowledge regarding the root canal morphology and current diagnostic aids one should have as both of these important factors going to affect the prognosis of the endodontic treatment. These two case reports describe the maxillary and mandibular first molars with multiple canals. After clinical and radiographic diagnosis, additional help of cone-beam computed tomography (CBCT) of mandibular molar has been taken to evaluate the morphology and canal pattern; while maxillary molar was evaluated using CBCT scan to evaluate the canal configuration and obturation. In CBCT evaluation, the mandibular molar was diagnosed with six separated canals with three mesial and three distal canals and with radix paramolaris and radix entomolaris. The maxillary molar had five canals with three mesiobuccal (MB) canals. Both molars were instrumented with conventional hand and rotary file systems and obturated by conventional lateral compaction method. The axial images from CBCT show Vertucci Type VIII canal pattern in both roots of first mandibular molars and in MB root of maxillary first molar Sert and Bayirli Type XVIII canal configuration and no accessory canal in distobuccal and palatal root. With the recent innovations in diagnostic and operating aids, we can come across many variations in the root canal morphology of both mandibular and maxillary teeth, especially multi-rooted one (i.e., molars), and the knowledge of which leads to successful endodontic treatment with an excellent prognosis. PMID:29259367
Misawa, Masashi; Kudo, Shin-Ei; Mori, Yuichi; Takeda, Kenichi; Maeda, Yasuharu; Kataoka, Shinichi; Nakamura, Hiroki; Kudo, Toyoki; Wakamura, Kunihiko; Hayashi, Takemasa; Katagiri, Atsushi; Baba, Toshiyuki; Ishida, Fumio; Inoue, Haruhiro; Nimura, Yukitaka; Oda, Msahiro; Mori, Kensaku
2017-05-01
Real-time characterization of colorectal lesions during colonoscopy is important for reducing medical costs, given that the need for a pathological diagnosis can be omitted if the accuracy of the diagnostic modality is sufficiently high. However, it is sometimes difficult for community-based gastroenterologists to achieve the required level of diagnostic accuracy. In this regard, we developed a computer-aided diagnosis (CAD) system based on endocytoscopy (EC) to evaluate cellular, glandular, and vessel structure atypia in vivo. The purpose of this study was to compare the diagnostic ability and efficacy of this CAD system with the performances of human expert and trainee endoscopists. We developed a CAD system based on EC with narrow-band imaging that allowed microvascular evaluation without dye (ECV-CAD). The CAD algorithm was programmed based on texture analysis and provided a two-class diagnosis of neoplastic or non-neoplastic, with probabilities. We validated the diagnostic ability of the ECV-CAD system using 173 randomly selected EC images (49 non-neoplasms, 124 neoplasms). The images were evaluated by the CAD and by four expert endoscopists and three trainees. The diagnostic accuracies for distinguishing between neoplasms and non-neoplasms were calculated. ECV-CAD had higher overall diagnostic accuracy than trainees (87.8 vs 63.4%; [Formula: see text]), but similar to experts (87.8 vs 84.2%; [Formula: see text]). With regard to high-confidence cases, the overall accuracy of ECV-CAD was also higher than trainees (93.5 vs 71.7%; [Formula: see text]) and comparable to experts (93.5 vs 90.8%; [Formula: see text]). ECV-CAD showed better diagnostic accuracy than trainee endoscopists and was comparable to that of experts. ECV-CAD could thus be a powerful decision-making tool for less-experienced endoscopists.
Kuric, Katelyn M; Harris, Bryan T; Morton, Dean; Azevedo, Bruno; Lin, Wei-Shao
2017-09-29
This clinical report describes a digital workflow using extraoral digital photographs and volumetric datasets from cone beam computed tomography (CBCT) imaging to create a 3-dimensional (3D), virtual patient with photorealistic appearance. In a patient with microstomia, hinge axis approximation, diagnostic casts simulating postextraction alveolar ridge profile, and facial simulation of prosthetic treatment outcome were completed in a 3D, virtual environment. The approach facilitated the diagnosis, communication, and patient acceptance of the treatment of maxillary and mandibular computer-aided design and computer-aided manufacturing (CAD-CAM) of immediate dentures at increased occlusal vertical dimension. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Diagnostic aids: the Surgical Sieve revisited.
Chai, Jason; Evans, Lloyd; Hughes, Tom
2017-08-01
Diagnostic errors are well documented in the literature and emphasise the need to teach diagnostic skills at an early stage in medical school to create effective and safe clinicians. Hence, there may be a place for diagnostic aids (such as the Surgical Sieve) that provide a framework for generating ideas about diagnoses. With repeated use of the Surgical Sieve in teaching sessions with students, and prompted by the traditional handheld wheels used in antenatal clinics, we developed the Compass Medicine, a handheld diagnostic wheel comprising three concentric discs attached at the centre. We report a preliminary study comparing the Surgical Sieve and the Compass Medicine in generating differential diagnoses. A total of 48 third-year medical students from Cardiff University participated in a study aimed at measuring the efficacy of diagnostic aids (Surgical Sieve and Compass Medicine) in generating diagnoses. We quantified the effect each aid had on the number of diagnoses generated, and compared the size of the effect between the two diagnostic aids. There may be a place for diagnostic aids that provide a framework for generating ideas about diagnoses RESULTS: The study suggests that both diagnostic aids prompted users to generate a greater number of diagnoses, but there was no significant difference in the size of effect between the two diagnostic aids. We hope that our study with diagnostic aids will encourage the use of robust tools to teach medical students an easily visualised framework for diagnostic thinking. © 2016 John Wiley & Sons Ltd and The Association for the Study of Medical Education.
Can computer-aided diagnosis (CAD) help radiologists find mammographically missed screening cancers?
NASA Astrophysics Data System (ADS)
Nishikawa, Robert M.; Giger, Maryellen L.; Schmidt, Robert A.; Papaioannou, John
2001-06-01
We present data from a pilot observer study whose goal is design a study to test the hypothesis that computer-aided diagnosis (CAD) can improve radiologists' performance in reading screening mammograms. In a prospective evaluation of our computer detection schemes, we have analyzed over 12,000 clinical exams. Retrospective review of the negative screening mammograms for all cancer cases found an indication of the cancer in 23 of these negative cases. The computer found 54% of these in our prospective testing. We added to these cases normal exams to create a dataset of 75 cases. Four radiologists experienced in mammography read the cases and gave their BI-RADS assessment and their confidence that the patient should be called back for diagnostic mammography. They did so once reading the films only and a second time reading with the computer aid. Three radiologists had no change in area under the ROC curve (mean Az of 0.73) and one improved from 0.73 to 0.78, but this difference failed to reach statistical significance (p equals 0.23). These data are being used to plan a larger more powerful study.
2014-06-03
nozzle exit) was developed to aid in porting the VENOM diagnostic to high-enthalpy impulse tunnels. Measurements were also made in the supersonic high...Colonius T, Fedorov AV. 2009. Alternate designs of ultrasonic absorptive coatings for hypersonic boundary layer control. AIAA Pap. No. 2009-4217 51. Craig
E-Assessment Data Compatibility Resolution Methodology with Bidirectional Data Transformation
ERIC Educational Resources Information Center
Malik, Kaleem Razzaq; Ahmad, Tauqir
2017-01-01
Electronic Assessment (E-Assessment) also known as computer aided assessment for the purposes involving diagnostic, formative or summative examining using data analysis. Digital assessments come commonly from social, academic, and adaptive learning in machine readable forms to deliver the machine scoring function. To achieve real-time and smart…
Harris, Bryan T; Montero, Daniel; Grant, Gerald T; Morton, Dean; Llop, Daniel R; Lin, Wei-Shao
2017-02-01
This clinical report proposes a digital workflow using 2-dimensional (2D) digital photographs, a 3D extraoral facial scan, and cone beam computed tomography (CBCT) volumetric data to create a 3D virtual patient with craniofacial hard tissue, remaining dentition (including surrounding intraoral soft tissue), and the realistic appearance of facial soft tissue at an exaggerated smile under static conditions. The 3D virtual patient was used to assist the virtual diagnostic tooth arrangement process, providing patient with a pleasing preoperative virtual smile design that harmonized with facial features. The 3D virtual patient was also used to gain patient's pretreatment approval (as a communication tool), design a prosthetically driven surgical plan for computer-guided implant surgery, and fabricate the computer-aided design and computer-aided manufacturing (CAD-CAM) interim prostheses. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Kuru, Kaya; Niranjan, Mahesan; Tunca, Yusuf; Osvank, Erhan; Azim, Tayyaba
2014-10-01
In general, medical geneticists aim to pre-diagnose underlying syndromes based on facial features before performing cytological or molecular analyses where a genotype-phenotype interrelation is possible. However, determining correct genotype-phenotype interrelationships among many syndromes is tedious and labor-intensive, especially for extremely rare syndromes. Thus, a computer-aided system for pre-diagnosis can facilitate effective and efficient decision support, particularly when few similar cases are available, or in remote rural districts where diagnostic knowledge of syndromes is not readily available. The proposed methodology, visual diagnostic decision support system (visual diagnostic DSS), employs machine learning (ML) algorithms and digital image processing techniques in a hybrid approach for automated diagnosis in medical genetics. This approach uses facial features in reference images of disorders to identify visual genotype-phenotype interrelationships. Our statistical method describes facial image data as principal component features and diagnoses syndromes using these features. The proposed system was trained using a real dataset of previously published face images of subjects with syndromes, which provided accurate diagnostic information. The method was tested using a leave-one-out cross-validation scheme with 15 different syndromes, each of comprised 5-9 cases, i.e., 92 cases in total. An accuracy rate of 83% was achieved using this automated diagnosis technique, which was statistically significant (p<0.01). Furthermore, the sensitivity and specificity values were 0.857 and 0.870, respectively. Our results show that the accurate classification of syndromes is feasible using ML techniques. Thus, a large number of syndromes with characteristic facial anomaly patterns could be diagnosed with similar diagnostic DSSs to that described in the present study, i.e., visual diagnostic DSS, thereby demonstrating the benefits of using hybrid image processing and ML-based computer-aided diagnostics for identifying facial phenotypes. Copyright © 2014. Published by Elsevier B.V.
Improving NAVFAC's total quality management of construction drawings with CLIPS
NASA Technical Reports Server (NTRS)
Antelman, Albert
1991-01-01
A diagnostic expert system to improve the quality of Naval Facilities Engineering Command (NAVFAC) construction drawings and specification is described. C Language Integrated Production System (CLIPS) and computer aided design layering standards are used in an expert system to check and coordinate construction drawings and specifications to eliminate errors and omissions.
Computer-aided diagnostic system for diffuse liver diseases with ultrasonography by neural networks
NASA Astrophysics Data System (ADS)
Ogawa, K.; Fukushima, M.; Kubota, K.; Hisa, N.
1998-12-01
The aim of the study is to establish a computer-aided diagnostic system for diffuse liver diseases such as chronic active hepatitis (CAH) and liver cirrhosis (LC). The authors introduced an artificial neural network in the classification of these diseases. In this system the neural network was trained by feature parameters extracted from B-mode ultrasonic images of normal liver (NL), CAH and LC. For input data the authors used six parameters calculated by a region of interest (ROI) and a parameter calculated by five ROIs in each image. They were variance of pixel values, coefficient of variation, annular Fourier power spectrum, longitudinal Fourier power spectrum which were calculated for the ROI, and variation of the means of the five ROIs. In addition, the authors used two more parameters calculated from a co-occurrence matrix of pixel values in the ROI. The results showed that the neural network classifier was 83.8% in sensitivity for LC, 90.0% in sensitivity for CAH and 93.6% in specificity, and the system was considered to be helpful for clinical and educational use.
Computer-Aided Recognition of Facial Attributes for Fetal Alcohol Spectrum Disorders.
Valentine, Matthew; Bihm, Dustin C J; Wolf, Lior; Hoyme, H Eugene; May, Philip A; Buckley, David; Kalberg, Wendy; Abdul-Rahman, Omar A
2017-12-01
To compare the detection of facial attributes by computer-based facial recognition software of 2-D images against standard, manual examination in fetal alcohol spectrum disorders (FASD). Participants were gathered from the Fetal Alcohol Syndrome Epidemiology Research database. Standard frontal and oblique photographs of children were obtained during a manual, in-person dysmorphology assessment. Images were submitted for facial analysis conducted by the facial dysmorphology novel analysis technology (an automated system), which assesses ratios of measurements between various facial landmarks to determine the presence of dysmorphic features. Manual blinded dysmorphology assessments were compared with those obtained via the computer-aided system. Areas under the curve values for individual receiver-operating characteristic curves revealed the computer-aided system (0.88 ± 0.02) to be comparable to the manual method (0.86 ± 0.03) in detecting patients with FASD. Interestingly, cases of alcohol-related neurodevelopmental disorder (ARND) were identified more efficiently by the computer-aided system (0.84 ± 0.07) in comparison to the manual method (0.74 ± 0.04). A facial gestalt analysis of patients with ARND also identified more generalized facial findings compared to the cardinal facial features seen in more severe forms of FASD. We found there was an increased diagnostic accuracy for ARND via our computer-aided method. As this category has been historically difficult to diagnose, we believe our experiment demonstrates that facial dysmorphology novel analysis technology can potentially improve ARND diagnosis by introducing a standardized metric for recognizing FASD-associated facial anomalies. Earlier recognition of these patients will lead to earlier intervention with improved patient outcomes. Copyright © 2017 by the American Academy of Pediatrics.
Bergman, Lars G; Fors, Uno GH
2008-01-01
Background Correct diagnosis in psychiatry may be improved by novel diagnostic procedures. Computerized Decision Support Systems (CDSS) are suggested to be able to improve diagnostic procedures, but some studies indicate possible problems. Therefore, it could be important to investigate CDSS systems with regard to their feasibility to improve diagnostic procedures as well as to save time. Methods This study was undertaken to compare the traditional 'paper and pencil' diagnostic method SCID1 with the computer-aided diagnostic system CB-SCID1 to ascertain processing time and accuracy of diagnoses suggested. 63 clinicians volunteered to participate in the study and to solve two paper-based cases using either a CDSS or manually. Results No major difference between paper and pencil and computer-supported diagnosis was found. Where a difference was found it was in favour of paper and pencil. For example, a significantly shorter time was found for paper and pencil for the difficult case, as compared to computer support. A significantly higher number of correct diagnoses were found in the diffilt case for the diagnosis 'Depression' using the paper and pencil method. Although a majority of the clinicians found the computer method supportive and easy to use, it took a longer time and yielded fewer correct diagnoses than with paper and pencil. Conclusion This study could not detect any major difference in diagnostic outcome between traditional paper and pencil methods and computer support for psychiatric diagnosis. Where there were significant differences, traditional paper and pencil methods were better than the tested CDSS and thus we conclude that CDSS for diagnostic procedures may interfere with diagnosis accuracy. A limitation was that most clinicians had not previously used the CDSS system under study. The results of this study, however, confirm that CDSS development for diagnostic purposes in psychiatry has much to deal with before it can be used for routine clinical purposes. PMID:18261222
NESTOR: A Computer-Based Medical Diagnostic Aid That Integrates Causal and Probabilistic Knowledge.
1984-11-01
indiidual conditional probabilities between one cause node and its effect node, but less common to know a joint conditional probability between a...PERFOAMING ORG. REPORT NUMBER * 7. AUTI4ORs) O Gregory F. Cooper 1 CONTRACT OR GRANT NUMBERIa) ONR N00014-81-K-0004 g PERFORMING ORGANIZATION NAME AND...ADDRESS 10. PROGRAM ELEMENT, PROJECT. TASK Department of Computer Science AREA & WORK UNIT NUMBERS Stanford University Stanford, CA 94305 USA 12. REPORT
A proposed computer diagnostic system for malignant melanoma (CDSMM).
Shao, S; Grams, R R
1994-04-01
This paper describes a computer diagnostic system for malignant melanoma. The diagnostic system is a rule base system based on image analyses and works under the PC windows environment. It consists of seven modules: I/O module, Patient/Clinic database, image processing module, classification module, rule base module and system control module. In the system, the image analyses are automatically carried out, and database management is efficient and fast. Both final clinic results and immediate results from various modules such as measured features, feature pictures and history records of the disease lesion can be presented on screen or printed out from each corresponding module or from the I/O module. The system can also work as a doctor's office-based tool to aid dermatologists with details not perceivable by the human eye. Since the system operates on a general purpose PC, it can be made portable if the I/O module is disconnected.
UWGSP6: a diagnostic radiology workstation of the future
NASA Astrophysics Data System (ADS)
Milton, Stuart W.; Han, Sang; Choi, Hyung-Sik; Kim, Yongmin
1993-06-01
The Univ. of Washington's Image Computing Systems Lab. (ICSL) has been involved in research into the development of a series of PACS workstations since the middle 1980's. The most recent research, a joint UW-IBM project, attempted to create a diagnostic radiology workstation using an IBM RISC System 6000 (RS6000) computer workstation and the X-Window system. While the results are encouraging, there are inherent limitations in the workstation hardware which prevent it from providing an acceptable level of functionality for diagnostic radiology. Realizing the RS6000 workstation's limitations, a parallel effort was initiated to design a workstation, UWGSP6 (Univ. of Washington Graphics System Processor #6), that provides the required functionality. This paper documents the design of UWGSP6, which not only addresses the requirements for a diagnostic radiology workstation in terms of display resolution, response time, etc., but also includes the processing performance necessary to support key functions needed in the implementation of algorithms for computer-aided diagnosis. The paper includes a description of the workstation architecture, and specifically its image processing subsystem. Verification of the design through hardware simulation is then discussed, and finally, performance of selected algorithms based on detailed simulation is provided.
Computer-Aided Diagnostic (CAD) Scheme by Use of Contralateral Subtraction Technique
NASA Astrophysics Data System (ADS)
Nagashima, Hiroyuki; Harakawa, Tetsumi
We developed a computer-aided diagnostic (CAD) scheme for detection of subtle image findings of acute cerebral infarction in brain computed tomography (CT) by using a contralateral subtraction technique. In our computerized scheme, the lateral inclination of image was first corrected automatically by rotating and shifting. The contralateral subtraction image was then derived by subtraction of reversed image from original image. Initial candidates for acute cerebral infarctions were identified using the multiple-thresholding and image filtering techniques. As the 1st step for removing false positive candidates, fourteen image features were extracted in each of the initial candidates. Halfway candidates were detected by applying the rule-based test with these image features. At the 2nd step, five image features were extracted using the overlapping scale with halfway candidates in interest slice and upper/lower slice image. Finally, acute cerebral infarction candidates were detected by applying the rule-based test with five image features. The sensitivity in the detection for 74 training cases was 97.4% with 3.7 false positives per image. The performance of CAD scheme for 44 testing cases had an approximate result to training cases. Our CAD scheme using the contralateral subtraction technique can reveal suspected image findings of acute cerebral infarctions in CT images.
Bharti, Puja; Mittal, Deepti; Ananthasivan, Rupa
2016-04-19
Diffuse liver diseases, such as hepatitis, fatty liver, and cirrhosis, are becoming a leading cause of fatality and disability all over the world. Early detection and diagnosis of these diseases is extremely important to save lives and improve effectiveness of treatment. Ultrasound imaging, a noninvasive diagnostic technique, is the most commonly used modality for examining liver abnormalities. However, the accuracy of ultrasound-based diagnosis depends highly on expertise of radiologists. Computer-aided diagnosis systems based on ultrasound imaging assist in fast diagnosis, provide a reliable "second opinion" for experts, and act as an effective tool to measure response of treatment on patients undergoing clinical trials. In this review, we first describe appearance of liver abnormalities in ultrasound images and state the practical issues encountered in characterization of diffuse liver diseases that can be addressed by software algorithms. We then discuss computer-aided diagnosis in general with features and classifiers relevant to diffuse liver diseases. In later sections of this paper, we review the published studies and describe the key findings of those studies. A concise tabular summary comparing image database, features extraction, feature selection, and classification algorithms presented in the published studies is also exhibited. Finally, we conclude with a summary of key findings and directions for further improvements in the areas of accuracy and objectiveness of computer-aided diagnosis. © The Author(s) 2016.
A hybrid lung and vessel segmentation algorithm for computer aided detection of pulmonary embolism
NASA Astrophysics Data System (ADS)
Raghupathi, Laks; Lakare, Sarang
2009-02-01
Advances in multi-detector technology have made CT pulmonary angiography (CTPA) a popular radiological tool for pulmonary emboli (PE) detection. CTPA provide rich detail of lung anatomy and is a useful diagnostic aid in highlighting even very small PE. However analyzing hundreds of slices is laborious and time-consuming for the practicing radiologist which may also cause misdiagnosis due to the presence of various PE look-alike. Computer-aided diagnosis (CAD) can be a potential second reader in providing key diagnostic information. Since PE occurs only in vessel arteries, it is important to mark this region of interest (ROI) during CAD preprocessing. In this paper, we present a new lung and vessel segmentation algorithm for extracting contrast-enhanced vessel ROI in CTPA. Existing approaches to segmentation either provide only the larger lung area without highlighting the vessels or is computationally prohibitive. In this paper, we propose a hybrid lung and vessel segmentation which uses an initial lung ROI and determines the vessels through a series of refinement steps. We first identify a coarse vessel ROI by finding the "holes" from the lung ROI. We then use the initial ROI as seed-points for a region-growing process while carefully excluding regions which are not relevant. The vessel segmentation mask covers 99% of the 259 PE from a real-world set of 107 CTPA. Further, our algorithm increases the net sensitivity of a prototype CAD system by 5-9% across all PE categories in the training and validation data sets. The average run-time of algorithm was only 100 seconds on a standard workstation.
Analysis of adventitious lung sounds originating from pulmonary tuberculosis.
Becker, K W; Scheffer, C; Blanckenberg, M M; Diacon, A H
2013-01-01
Tuberculosis is a common and potentially deadly infectious disease, usually affecting the respiratory system and causing the sound properties of symptomatic infected lungs to differ from non-infected lungs. Auscultation is often ruled out as a reliable diagnostic technique for TB due to the random distribution of the infection and the varying severity of damage to the lungs. However, advancements in signal processing techniques for respiratory sounds can improve the potential of auscultation far beyond the capabilities of the conventional mechanical stethoscope. Though computer-based signal analysis of respiratory sounds has produced a significant body of research, there have not been any recent investigations into the computer-aided analysis of lung sounds associated with pulmonary Tuberculosis (TB), despite the severity of the disease in many countries. In this paper, respiratory sounds were recorded from 14 locations around the posterior and anterior chest walls of healthy volunteers and patients infected with pulmonary TB. The most significant signal features in both the time and frequency domains associated with the presence of TB, were identified by using the statistical overlap factor (SOF). These features were then employed to train a neural network to automatically classify the auscultation recordings into their respective healthy or TB-origin categories. The neural network yielded a diagnostic accuracy of 73%, but it is believed that automated filtering of the noise in the clinics, more training samples and perhaps other signal processing methods can improve the results of future studies. This work demonstrates the potential of computer-aided auscultation as an aid for the diagnosis and treatment of TB.
Image-based diagnostic aid for interstitial lung disease with secondary data integration
NASA Astrophysics Data System (ADS)
Depeursinge, Adrien; Müller, Henning; Hidki, Asmâa; Poletti, Pierre-Alexandre; Platon, Alexandra; Geissbuhler, Antoine
2007-03-01
Interstitial lung diseases (ILDs) are a relatively heterogeneous group of around 150 illnesses with often very unspecific symptoms. The most complete imaging method for the characterisation of ILDs is the high-resolution computed tomography (HRCT) of the chest but a correct interpretation of these images is difficult even for specialists as many diseases are rare and thus little experience exists. Moreover, interpreting HRCT images requires knowledge of the context defined by clinical data of the studied case. A computerised diagnostic aid tool based on HRCT images with associated medical data to retrieve similar cases of ILDs from a dedicated database can bring quick and precious information for example for emergency radiologists. The experience from a pilot project highlighted the need for detailed database containing high-quality annotations in addition to clinical data. The state of the art is studied to identify requirements for image-based diagnostic aid for interstitial lung disease with secondary data integration. The data acquisition steps are detailed. The selection of the most relevant clinical parameters is done in collaboration with lung specialists from current literature, along with knowledge bases of computer-based diagnostic decision support systems. In order to perform high-quality annotations of the interstitial lung tissue in the HRCT images an annotation software and its own file format is implemented for DICOM images. A multimedia database is implemented to store ILD cases with clinical data and annotated image series. Cases from the University & University Hospitals of Geneva (HUG) are retrospectively and prospectively collected to populate the database. Currently, 59 cases with certified diagnosis and their clinical parameters are stored in the database as well as 254 image series of which 26 have their regions of interest annotated. The available data was used to test primary visual features for the classification of lung tissue patterns. These features show good discriminative properties for the separation of five classes of visual observations.
Balmforth, Damian; Chacko, Jacob; Uppal, Rakesh
2016-10-01
A best evidence topic was constructed according to a structured protocol. The question addressed was whether (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) aids the diagnosis of prosthetic valve endocarditis (PVE)? A total of 107 publications were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The reported outcome of all studies was a final diagnosis of confirmed endocarditis on follow-up. All the six studies were non-randomized, single-centre, observational studies and thus represented level 3 evidence. The diagnostic capability of PET/CT for PVE was compared with that of the modified Duke Criteria and echocardiography, and reported in terms of sensitivity, specificity and positive and negative predictive values. All studies demonstrated an increased sensitivity for the diagnosis of PVE when PET/CT was combined with the modified Duke Criteria on admission. A higher SUVmax on PET was found to be significantly associated with a confirmed diagnosis of endocarditis and an additional diagnostic benefit of PET/CT angiography over conventional PET/non-enhanced CT is reported due to improved anatomical resolution. However, PET/CT was found to be unreliable in the early postoperative period due to its inability to distinguish between infection and residual postoperative inflammatory changes. PET/CT was also found to be poor at diagnosing cases of native valve endocarditis. We conclude that PET/CT aids in the diagnosis of PVE when combined with the modified Duke Criteria on admission by increasing the diagnostic sensitivity. The diagnostic ability of PET/CT can be potentiated by the use of PET/CTA; however, its use may be unreliable in the early postoperative period or in native valve endocarditis. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Baltzer, Pascal Andreas Thomas; Renz, Diane M; Kullnig, Petra E; Gajda, Mieczyslaw; Camara, Oumar; Kaiser, Werner A
2009-04-01
The identification of the most suspect enhancing part of a lesion is regarded as a major diagnostic criterion in dynamic magnetic resonance mammography. Computer-aided diagnosis (CAD) software allows the semi-automatic analysis of the kinetic characteristics of complete enhancing lesions, providing additional information about lesion vasculature. The diagnostic value of this information has not yet been quantified. Consecutive patients from routine diagnostic studies (1.5 T, 0.1 mmol gadopentetate dimeglumine, dynamic gradient-echo sequences at 1-minute intervals) were analyzed prospectively using CAD. Dynamic sequences were processed and reduced to a parametric map. Curve types were classified by initial signal increase (not significant, intermediate, and strong) and the delayed time course of signal intensity (continuous, plateau, and washout). Lesion enhancement was measured using CAD. The most suspect curve, the curve-type distribution percentage, and combined dynamic data were compared. Statistical analysis included logistic regression analysis and receiver-operating characteristic analysis. Fifty-one patients with 46 malignant and 44 benign lesions were enrolled. On receiver-operating characteristic analysis, the most suspect curve showed diagnostic accuracy of 76.7 +/- 5%. In comparison, the curve-type distribution percentage demonstrated accuracy of 80.2 +/- 4.9%. Combined dynamic data had the highest diagnostic accuracy (84.3 +/- 4.2%). These differences did not achieve statistical significance. With appropriate cutoff values, sensitivity and specificity, respectively, were found to be 80.4% and 72.7% for the most suspect curve, 76.1% and 83.6% for the curve-type distribution percentage, and 78.3% and 84.5% for both parameters. The integration of whole-lesion dynamic data tends to improve specificity. However, no statistical significance backs up this finding.
Pathapati, Deepti; Shinkar, Pawan Gulabrao; kumar, Satya Awadhesh; Jha; Dattatreya, Palanki Satya; Chigurupati, Namrata; Chigurupati, Mohana Vamsy; Rao, Vatturi Venkata Satya Prabhakar
2017-01-01
The authors report an interesting coincidental unearthing by 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) of a potentially serious medical condition of emphysematous pyelonephritis in a case of nasopharyngeal carcinoma. The management by conservative ureteric stenting and antibiotics was done with gratifying clinical outcome. PMID:28242985
Digital pathology in nephrology clinical trials, research, and pathology practice.
Barisoni, Laura; Hodgin, Jeffrey B
2017-11-01
In this review, we will discuss (i) how the recent advancements in digital technology and computational engineering are currently applied to nephropathology in the setting of clinical research, trials, and practice; (ii) the benefits of the new digital environment; (iii) how recognizing its challenges provides opportunities for transformation; and (iv) nephropathology in the upcoming era of kidney precision and predictive medicine. Recent studies highlighted how new standardized protocols facilitate the harmonization of digital pathology database infrastructure and morphologic, morphometric, and computer-aided quantitative analyses. Digital pathology enables robust protocols for clinical trials and research, with the potential to identify previously underused or unrecognized clinically useful parameters. The integration of digital pathology with molecular signatures is leading the way to establishing clinically relevant morpho-omic taxonomies of renal diseases. The introduction of digital pathology in clinical research and trials, and the progressive implementation of the modern software ecosystem, opens opportunities for the development of new predictive diagnostic paradigms and computer-aided algorithms, transforming the practice of renal disease into a modern computational science.
Computer aided detection system for lung cancer using computer tomography scans
NASA Astrophysics Data System (ADS)
Mahesh, Shanthi; Rakesh, Spoorthi; Patil, Vidya C.
2018-04-01
Lung Cancer is a disease can be defined as uncontrolled cell growth in tissues of the lung. If we detect the Lung Cancer in its early stage, then that could be the key of its cure. In this work the non-invasive methods are studied for assisting in nodule detection. It supplies a Computer Aided Diagnosis System (CAD) for early detection of lung cancer nodules from the Computer Tomography (CT) images. CAD system is the one which helps to improve the diagnostic performance of radiologists in their image interpretations. The main aim of this technique is to develop a CAD system for finding the lung cancer using the lung CT images and classify the nodule as Benign or Malignant. For classifying cancer cells, SVM classifier is used. Here, image processing techniques have been used to de-noise, to enhance, for segmentation and edge detection of an image is used to extract the area, perimeter and shape of nodule. The core factors of this research are Image quality and accuracy.
NASA Astrophysics Data System (ADS)
Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru
2007-03-01
Multislice CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multislice CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. Moreover, we have provided diagnostic assistance methods to medical screening specialists by using a lung cancer screening algorithm built into mobile helical CT scanner for the lung cancer mass screening done in the region without the hospital. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system.
Khumrin, Piyapong; Ryan, Anna; Judd, Terry; Verspoor, Karin
2017-01-01
Computer-aided learning systems (e-learning systems) can help medical students gain more experience with diagnostic reasoning and decision making. Within this context, providing feedback that matches students' needs (i.e. personalised feedback) is both critical and challenging. In this paper, we describe the development of a machine learning model to support medical students' diagnostic decisions. Machine learning models were trained on 208 clinical cases presenting with abdominal pain, to predict five diagnoses. We assessed which of these models are likely to be most effective for use in an e-learning tool that allows students to interact with a virtual patient. The broader goal is to utilise these models to generate personalised feedback based on the specific patient information requested by students and their active diagnostic hypotheses.
Unusual Radiographic Presentation of Pneumocystis Pneumonia in a Patient with AIDS.
Block, Brian L; Mehta, Tejas; Ortiz, Gabriel M; Ferris, Sean P; Vu, Thienkhai H; Huang, Laurence; Cattamanchi, Adithya
2017-01-01
Pneumocystis jirovecii pneumonia (PCP) typically presents as an interstitial and alveolar process with ground glass opacities on chest computed tomography (CT). The absence of ground glass opacities on chest CT is thought to have a high negative predictive value for PCP in individuals with AIDS. Here, we report a case of PCP in a man with AIDS who presented to our hospital with subacute shortness of breath and a nonproductive cough. While his chest CT revealed diffuse nodular rather than ground glass opacities, bronchoscopy with bronchoalveolar lavage and transbronchial biopsies confirmed the diagnosis of PCP and did not identify additional pathogens. PCP was not the expected diagnosis based on chest CT, but it otherwise fit well with the patient's clinical and laboratory presentation. In the era of combination antiretroviral therapy, routine prophylaxis for PCP, and increased use of computed tomography, it may be that PCP will increasingly present with nonclassical chest radiographic patterns. Clinicians should be aware of this presentation when selecting diagnostic and management strategies.
Unusual Radiographic Presentation of Pneumocystis Pneumonia in a Patient with AIDS
Mehta, Tejas; Ortiz, Gabriel M.; Ferris, Sean P.; Vu, Thienkhai H.; Huang, Laurence; Cattamanchi, Adithya
2017-01-01
Pneumocystis jirovecii pneumonia (PCP) typically presents as an interstitial and alveolar process with ground glass opacities on chest computed tomography (CT). The absence of ground glass opacities on chest CT is thought to have a high negative predictive value for PCP in individuals with AIDS. Here, we report a case of PCP in a man with AIDS who presented to our hospital with subacute shortness of breath and a nonproductive cough. While his chest CT revealed diffuse nodular rather than ground glass opacities, bronchoscopy with bronchoalveolar lavage and transbronchial biopsies confirmed the diagnosis of PCP and did not identify additional pathogens. PCP was not the expected diagnosis based on chest CT, but it otherwise fit well with the patient's clinical and laboratory presentation. In the era of combination antiretroviral therapy, routine prophylaxis for PCP, and increased use of computed tomography, it may be that PCP will increasingly present with nonclassical chest radiographic patterns. Clinicians should be aware of this presentation when selecting diagnostic and management strategies. PMID:29362681
NASA Astrophysics Data System (ADS)
Tan, Shanjuan; Feng, Feifei; Wu, Yongjun; Wu, Yiming
To develop a computer-aided diagnostic scheme by using an artificial neural network (ANN) combined with tumor markers for diagnosis of hepatic carcinoma (HCC) as a clinical assistant method. 140 serum samples (50 malignant, 40 benign and 50 normal) were analyzed for α-fetoprotein (AFP), carbohydrate antigen 125 (CA125), carcinoembryonic antigen (CEA), sialic acid (SA) and calcium (Ca). The five tumor marker values were then used as ANN inputs data. The result of ANN was compared with that of discriminant analysis by receiver operating characteristic (ROC) curve (AUC) analysis. The diagnostic accuracy of ANN and discriminant analysis among all samples of the test group was 95.5% and 79.3%, respectively. Analysis of multiple tumor markers based on ANN may be a better choice than the traditional statistical methods for differentiating HCC from benign or normal.
Chang, Ruey-Feng; Lee, Chung-Chien; Lo, Chung-Ming
2016-09-01
The lifetime prevalence of shoulder pain approaches 70%, which is mostly attributable to rotator cuff lesions such as inflammation, calcific tendinitis and tears. On clinical examination, shoulder ultrasound is recommended for the detection of lesions. However, there exists inter-operator variability in diagnostic accuracy because of differences in the experience and expertise of operators. In this study, a computer-aided diagnosis (CAD) system was developed to assist ultrasound operators in diagnosing rotator cuff lesions and to improve the practicality of ultrasound examination. The collected cases included 43 cases of inflammation, 30 cases of calcific tendinitis and 26 tears. For each case, the lesion area and texture features were extracted from the entire lesions and combined in a multinomial logistic regression classifier for lesion classification. The proposed CAD achieved an accuracy of 87.9%. The individual accuracy of this CAD system was 88.4% for inflammation, 83.3% for calcific tendinitis and 92.3% for tears. Cohen's k was 0.798. On the basis of its diagnostic performance, clinical use of this CAD technique has promise. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Diagnostic Imaging of the Hepatobiliary System: An Update.
Marolf, Angela J
2017-05-01
Recent advances in diagnostic imaging of the hepatobiliary system include MRI, computed tomography (CT), contrast-enhanced ultrasound, and ultrasound elastography. With the advent of multislice CT scanners, sedated examinations in veterinary patients are feasible, increasing the utility of this imaging modality. CT and MRI provide additional information for dogs and cats with hepatobiliary diseases due to lack of superimposition of structures, operator dependence, and through intravenous contrast administration. Advanced ultrasound methods can offer complementary information to standard ultrasound imaging. These newer imaging modalities assist clinicians by aiding diagnosis, prognostication, and surgical planning. Copyright © 2016 Elsevier Inc. All rights reserved.
Kim, Kwang Baek; Kim, Chang Won
2015-01-01
Accurate measures of liver fat content are essential for investigating hepatic steatosis. For a noninvasive inexpensive ultrasonographic analysis, it is necessary to validate the quantitative assessment of liver fat content so that fully automated reliable computer-aided software can assist medical practitioners without any operator subjectivity. In this study, we attempt to quantify the hepatorenal index difference between the liver and the kidney with respect to the multiple severity status of hepatic steatosis. In order to do this, a series of carefully designed image processing techniques, including fuzzy stretching and edge tracking, are applied to extract regions of interest. Then, an unsupervised neural learning algorithm, the self-organizing map, is designed to establish characteristic clusters from the image, and the distribution of the hepatorenal index values with respect to the different levels of the fatty liver status is experimentally verified to estimate the differences in the distribution of the hepatorenal index. Such findings will be useful in building reliable computer-aided diagnostic software if combined with a good set of other characteristic feature sets and powerful machine learning classifiers in the future.
Kim, Kwang Baek
2015-01-01
Accurate measures of liver fat content are essential for investigating hepatic steatosis. For a noninvasive inexpensive ultrasonographic analysis, it is necessary to validate the quantitative assessment of liver fat content so that fully automated reliable computer-aided software can assist medical practitioners without any operator subjectivity. In this study, we attempt to quantify the hepatorenal index difference between the liver and the kidney with respect to the multiple severity status of hepatic steatosis. In order to do this, a series of carefully designed image processing techniques, including fuzzy stretching and edge tracking, are applied to extract regions of interest. Then, an unsupervised neural learning algorithm, the self-organizing map, is designed to establish characteristic clusters from the image, and the distribution of the hepatorenal index values with respect to the different levels of the fatty liver status is experimentally verified to estimate the differences in the distribution of the hepatorenal index. Such findings will be useful in building reliable computer-aided diagnostic software if combined with a good set of other characteristic feature sets and powerful machine learning classifiers in the future. PMID:26247023
Selection of examples in case-based computer-aided decision systems
Mazurowski, Maciej A.; Zurada, Jacek M.; Tourassi, Georgia D.
2013-01-01
Case-based computer-aided decision (CB-CAD) systems rely on a database of previously stored, known examples when classifying new, incoming queries. Such systems can be particularly useful since they do not need retraining every time a new example is deposited in the case base. The adaptive nature of case-based systems is well suited to the current trend of continuously expanding digital databases in the medical domain. To maintain efficiency, however, such systems need sophisticated strategies to effectively manage the available evidence database. In this paper, we discuss the general problem of building an evidence database by selecting the most useful examples to store while satisfying existing storage requirements. We evaluate three intelligent techniques for this purpose: genetic algorithm-based selection, greedy selection and random mutation hill climbing. These techniques are compared to a random selection strategy used as the baseline. The study is performed with a previously presented CB-CAD system applied for false positive reduction in screening mammograms. The experimental evaluation shows that when the development goal is to maximize the system’s diagnostic performance, the intelligent techniques are able to reduce the size of the evidence database to 37% of the original database by eliminating superfluous and/or detrimental examples while at the same time significantly improving the CAD system’s performance. Furthermore, if the case-base size is a main concern, the total number of examples stored in the system can be reduced to only 2–4% of the original database without a decrease in the diagnostic performance. Comparison of the techniques shows that random mutation hill climbing provides the best balance between the diagnostic performance and computational efficiency when building the evidence database of the CB-CAD system. PMID:18854606
Computer aided diagnosis of diabetic peripheral neuropathy
NASA Astrophysics Data System (ADS)
Chekh, Viktor; Soliz, Peter; McGrew, Elizabeth; Barriga, Simon; Burge, Mark; Luan, Shuang
2014-03-01
Diabetic peripheral neuropathy (DPN) refers to the nerve damage that can occur in diabetes patients. It most often affects the extremities, such as the feet, and can lead to peripheral vascular disease, deformity, infection, ulceration, and even amputation. The key to managing diabetic foot is prevention and early detection. Unfortunately, current existing diagnostic techniques are mostly based on patient sensations and exhibit significant inter- and intra-observer differences. We have developed a computer aided diagnostic (CAD) system for diabetic peripheral neuropathy. The thermal response of the feet of diabetic patients following cold stimulus is captured using an infrared camera. The plantar foot in the images from a thermal video are segmented and registered for tracking points or specific regions. The temperature recovery of each point on the plantar foot is extracted using our bio-thermal model and analyzed. The regions that exhibit abnormal ability to recover are automatically identified to aid the physicians to recognize problematic areas. The key to our CAD system is the segmentation of infrared video. The main challenges for segmenting infrared video compared to normal digital video are (1) as the foot warms up, it also warms up the surrounding, creating an ever changing contrast; and (2) there may be significant motion during imaging. To overcome this, a hybrid segmentation algorithm was developed based on a number of techniques such as continuous max-flow, model based segmentation, shape preservation, convex hull, and temperature normalization. Verifications of the automatic segmentation and registration using manual segmentation and markers show good agreement.
Structure and Computation in Immunoreagent Design: From Diagnostics to Vaccines.
Gourlay, Louise; Peri, Claudio; Bolognesi, Martino; Colombo, Giorgio
2017-12-01
Novel immunological tools for efficient diagnosis and treatment of emerging infections are urgently required. Advances in the diagnostic and vaccine development fields are continuously progressing, with reverse vaccinology and structural vaccinology (SV) methods for antigen identification and structure-based antigen (re)design playing increasingly relevant roles. SV, in particular, is predicted to be the front-runner in the future development of diagnostics and vaccines targeting challenging diseases such as AIDS and cancer. We review state-of-the-art methodologies for structure-based epitope identification and antigen design, with specific applicative examples. We highlight the implications of such methods for the engineering of biomolecules with improved immunological properties, potential diagnostic and/or therapeutic uses, and discuss the perspectives of structure-based rational design for the production of advanced immunoreagents. Copyright © 2017 Elsevier Ltd. All rights reserved.
Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study.
Sunwoo, Leonard; Kim, Young Jae; Choi, Seung Hong; Kim, Kwang-Gi; Kang, Ji Hee; Kang, Yeonah; Bae, Yun Jung; Yoo, Roh-Eul; Kim, Jihang; Lee, Kyong Joon; Lee, Seung Hyun; Choi, Byung Se; Jung, Cheolkyu; Sohn, Chul-Ho; Kim, Jae Hyoung
2017-01-01
To assess the effect of computer-aided detection (CAD) of brain metastasis (BM) on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR) imaging using follow-up imaging and consensus as the reference standard. The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents) interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP) per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC) method was used to determine the improvement in the diagnostic accuracy. The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM) of 0.874 (without CAD) vs. 0.898 (with CAD) according to JAFROC analysis (p < 0.01). Statistically significant improvement was noted only for less-experienced reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p < 0.01). The additional time required to review the CAD results was approximately 72 sec (40% of the total review time). CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.
Hirose, Tomohiro; Nitta, Norihisa; Shiraishi, Junji; Nagatani, Yukihiro; Takahashi, Masashi; Murata, Kiyoshi
2008-12-01
The aim of this study was to evaluate the usefulness of computer-aided diagnosis (CAD) software for the detection of lung nodules on multidetector-row computed tomography (MDCT) in terms of improvement in radiologists' diagnostic accuracy in detecting lung nodules, using jackknife free-response receiver-operating characteristic (JAFROC) analysis. Twenty-one patients (6 without and 15 with lung nodules) were selected randomly from 120 consecutive thoracic computed tomographic examinations. The gold standard for the presence or absence of nodules in the observer study was determined by consensus of two radiologists. Six expert radiologists participated in a free-response receiver operating characteristic study for the detection of lung nodules on MDCT, in which cases were interpreted first without and then with the output of CAD software. Radiologists were asked to indicate the locations of lung nodule candidates on the monitor with their confidence ratings for the presence of lung nodules. The performance of the CAD software indicated that the sensitivity in detecting lung nodules was 71.4%, with 0.95 false-positive results per case. When radiologists used the CAD software, the average sensitivity improved from 39.5% to 81.0%, with an increase in the average number of false-positive results from 0.14 to 0.89 per case. The average figure-of-merit values for the six radiologists were 0.390 without and 0.845 with the output of the CAD software, and there was a statistically significant difference (P < .0001) using the JAFROC analysis. The CAD software for the detection of lung nodules on MDCT has the potential to assist radiologists by increasing their accuracy.
Kluge, Annette; Grauel, Britta; Burkolter, Dina
2013-03-01
Two studies are presented in which the design of a procedural aid and the impact of an additional decision aid for process control were assessed. In Study 1, a procedural aid was developed that avoids imposing unnecessary extraneous cognitive load on novices when controlling a complex technical system. This newly designed procedural aid positively affected germane load, attention, satisfaction, motivation, knowledge acquisition and diagnostic speed for novel faults. In Study 2, the effect of a decision aid for use before the procedural aid was investigated, which was developed based on an analysis of diagnostic errors committed in Study 1. Results showed that novices were able to diagnose both novel faults and practised faults, and were even faster at diagnosing novel faults. This research contributes to the question of how to optimally support novices in dealing with technical faults in process control. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Giger, Maryellen L.; Chan, Heang-Ping; Boone, John
2008-01-01
The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists’ goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists—as opposed to a completely automatic computer interpretation—focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous—from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects—collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more—from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis. PMID:19175137
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giger, Maryellen L.; Chan, Heang-Ping; Boone, John
2008-12-15
The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities thatmore » are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.« less
Multiphasic Health Testing in the Clinic Setting
LaDou, Joseph
1971-01-01
The economy of automated multiphasic health testing (amht) activities patterned after the high-volume Kaiser program can be realized in low-volume settings. amht units have been operated at daily volumes of 20 patients in three separate clinical environments. These programs have displayed economics entirely compatible with cost figures published by the established high-volume centers. This experience, plus the expanding capability of small, general purpose, digital computers (minicomputers) indicates that a group of six or more physicians generating 20 laboratory appraisals per day can economically justify a completely automated multiphasic health testing facility. This system would reside in the clinic or hospital where it is used and can be configured to do analyses such as electrocardiography and generate laboratory reports, and communicate with large computer systems in university medical centers. Experience indicates that the most effective means of implementing these benefits of automation is to make them directly available to the medical community with the physician playing the central role. Economic justification of a dedicated computer through low-volume health testing then allows, as a side benefit, automation of administrative as well as other diagnostic activities—for example, patient billing, computer-aided diagnosis, and computer-aided therapeutics. PMID:4935771
An intelligent advisory system for pre-launch processing
NASA Technical Reports Server (NTRS)
Engrand, Peter A.; Mitchell, Tami
1991-01-01
The shuttle system of interest in this paper is the shuttle's data processing system (DPS). The DPS is composed of the following: (1) general purpose computers (GPC); (2) a multifunction CRT display system (MCDS); (3) mass memory units (MMU); and (4) a multiplexer/demultiplexer (MDM) and related software. In order to ensure the correct functioning of shuttle systems, some level of automatic error detection has been incorporated into all shuttle systems. For the DPS, error detection equipment has been incorporated into all of its subsystems. The automated diagnostic system, (MCDS) diagnostic tool, that aids in a more efficient processing of the DPS is described.
Drew, Mark S.
2016-01-01
Cutaneous melanoma is the most life-threatening form of skin cancer. Although advanced melanoma is often considered as incurable, if detected and excised early, the prognosis is promising. Today, clinicians use computer vision in an increasing number of applications to aid early detection of melanoma through dermatological image analysis (dermoscopy images, in particular). Colour assessment is essential for the clinical diagnosis of skin cancers. Due to this diagnostic importance, many studies have either focused on or employed colour features as a constituent part of their skin lesion analysis systems. These studies range from using low-level colour features, such as simple statistical measures of colours occurring in the lesion, to availing themselves of high-level semantic features such as the presence of blue-white veil, globules, or colour variegation in the lesion. This paper provides a retrospective survey and critical analysis of contributions in this research direction. PMID:28096807
Welter, Petra; Riesmeier, Jörg; Fischer, Benedikt; Grouls, Christoph; Kuhl, Christiane; Deserno, Thomas M
2011-01-01
It is widely accepted that content-based image retrieval (CBIR) can be extremely useful for computer-aided diagnosis (CAD). However, CBIR has not been established in clinical practice yet. As a widely unattended gap of integration, a unified data concept for CBIR-based CAD results and reporting is lacking. Picture archiving and communication systems and the workflow of radiologists must be considered for successful data integration to be achieved. We suggest that CBIR systems applied to CAD should integrate their results in a picture archiving and communication systems environment such as Digital Imaging and Communications in Medicine (DICOM) structured reporting documents. A sample DICOM structured reporting template adaptable to CBIR and an appropriate integration scheme is presented. The proposed CBIR data concept may foster the promulgation of CBIR systems in clinical environments and, thereby, improve the diagnostic process.
Riesmeier, Jörg; Fischer, Benedikt; Grouls, Christoph; Kuhl, Christiane; Deserno (né Lehmann), Thomas M
2011-01-01
It is widely accepted that content-based image retrieval (CBIR) can be extremely useful for computer-aided diagnosis (CAD). However, CBIR has not been established in clinical practice yet. As a widely unattended gap of integration, a unified data concept for CBIR-based CAD results and reporting is lacking. Picture archiving and communication systems and the workflow of radiologists must be considered for successful data integration to be achieved. We suggest that CBIR systems applied to CAD should integrate their results in a picture archiving and communication systems environment such as Digital Imaging and Communications in Medicine (DICOM) structured reporting documents. A sample DICOM structured reporting template adaptable to CBIR and an appropriate integration scheme is presented. The proposed CBIR data concept may foster the promulgation of CBIR systems in clinical environments and, thereby, improve the diagnostic process. PMID:21672913
Automated Dermoscopy Image Analysis of Pigmented Skin Lesions
Baldi, Alfonso; Quartulli, Marco; Murace, Raffaele; Dragonetti, Emanuele; Manganaro, Mario; Guerra, Oscar; Bizzi, Stefano
2010-01-01
Dermoscopy (dermatoscopy, epiluminescence microscopy) is a non-invasive diagnostic technique for the in vivo observation of pigmented skin lesions (PSLs), allowing a better visualization of surface and subsurface structures (from the epidermis to the papillary dermis). This diagnostic tool permits the recognition of morphologic structures not visible by the naked eye, thus opening a new dimension in the analysis of the clinical morphologic features of PSLs. In order to reduce the learning-curve of non-expert clinicians and to mitigate problems inherent in the reliability and reproducibility of the diagnostic criteria used in pattern analysis, several indicative methods based on diagnostic algorithms have been introduced in the last few years. Recently, numerous systems designed to provide computer-aided analysis of digital images obtained by dermoscopy have been reported in the literature. The goal of this article is to review these systems, focusing on the most recent approaches based on content-based image retrieval systems (CBIR). PMID:24281070
Computational intelligence for target assessment in Parkinson's disease
NASA Astrophysics Data System (ADS)
Micheli-Tzanakou, Evangelia; Hamilton, J. L.; Zheng, J.; Lehman, Richard M.
2001-11-01
Recent advances in image and signal processing have created a new challenging environment for biomedical engineers. Methods that were developed for different fields are now finding a fertile ground in biomedicine, especially in the analysis of bio-signals and in the understanding of images. More and more, these methods are used in the operating room, helping surgeons, and in the physician's office as aids for diagnostic purposes. Neural Network (NN) research on the other hand, has gone a long way in the past decade. NNs now consist of many thousands of highly interconnected processing elements that can encode, store and recall relationships between different patterns by altering the weighting coefficients of inputs in a systematic way. Although they can generate reasonable outputs from unknown input patterns, and can tolerate a great deal of noise, they are very slow when run on a serial machine. We have used advanced signal processing and innovative image processing methods that are used along with computational intelligence for diagnostic purposes and as visualization aids inside and outside the operating room. Applications to be discussed include EEGs and field potentials in Parkinson's disease along with 3D reconstruction of MR or fMR brain images in Parkinson's patients, are currently used in the operating room for Pallidotomies and Deep Brain Stimulation (DBS).
NASA Technical Reports Server (NTRS)
Yaden, David B., Jr.
1991-01-01
An important part of NASA's mission involves the secondary application of its technologies in the public and private sectors. One current application being developed is The Adult Literacy Evaluator, a simulation-based diagnostic tool designed to assess the operant literacy abilities of adults having difficulties in learning to read and write. Using Intelligent Computer-Aided Training (ICAT) system technology in addition to speech recognition, closed-captioned television (CCTV), live video and other state-of-the-art graphics and storage capabilities, this project attempts to overcome the negative effects of adult literacy assessment by allowing the client to interact with an intelligent computer system which simulates real-life literacy activities and materials and which measures literacy performance in the actual context of its use. The specific objectives of the project are as follows: (1) to develop a simulation-based diagnostic tool to assess adults' prior knowledge about reading and writing processes in actual contexts of application; (2) to provide a profile of readers' strengths and weaknesses; and (3) to suggest instructional strategies and materials which can be used as a beginning point for remediation. In the first and development phase of the project, descriptions of literacy events and environments are being written and functional literacy documents analyzed for their components. From these descriptions, scripts are being generated which define the interaction between the student, an on-screen guide and the simulated literacy environment.
Lee, S C; Lee, E T; Kingsley, R M; Wang, Y; Russell, D; Klein, R; Warn, A
2001-04-01
To investigate whether a computer vision system is comparable with humans in detecting early retinal lesions of diabetic retinopathy using color fundus photographs. A computer system has been developed using image processing and pattern recognition techniques to detect early lesions of diabetic retinopathy (hemorrhages and microaneurysms, hard exudates, and cotton-wool spots). Color fundus photographs obtained from American Indians in Oklahoma were used in developing and testing the system. A set of 369 color fundus slides were used to train the computer system using 3 diagnostic categories: lesions present, questionable, or absent (Y/Q/N). A different set of 428 slides were used to test and evaluate the system, and its diagnostic results were compared with those of 2 human experts-the grader at the University of Wisconsin Fundus Photograph Reading Center (Madison) and a general ophthalmologist. The experiments included comparisons using 3 (Y/Q/N) and 2 diagnostic categories (Y/N) (questionable cases excluded in the latter). In the training phase, the agreement rates, sensitivity, and specificity in detecting the 3 lesions between the retinal specialist and the computer system were all above 90%. The kappa statistics were high (0.75-0.97), indicating excellent agreement between the specialist and the computer system. In the testing phase, the results obtained between the computer system and human experts were consistent with those of the training phase, and they were comparable with those between the human experts. The performance of the computer vision system in diagnosing early retinal lesions was comparable with that of human experts. Therefore, this mobile, electronically easily accessible, and noninvasive computer system, could become a mass screening tool and a clinical aid in diagnosing early lesions of diabetic retinopathy.
Behavioral Health in the Patient Centered Medical Home: Meeting the Quadruple Aim Part 1
2011-01-24
visits) Pre-clinician diagnostic aid Patient education materials Psychosocial options Care Facilitator assisted follow-up option Aggressive...clinician diagnostic aid Patient education materials Psychosocial options Care Facilitator assisted follow-up option Aggressive facilitator outreach...visits) Pre-clinician diagnostic aid Patient education materials Psychosocial options Care Facilitator assisted follow-up option Aggressive
Barchuk, A A; Podolsky, M D; Tarakanov, S A; Kotsyuba, I Yu; Gaidukov, V S; Kuznetsov, V I; Merabishvili, V M; Barchuk, A S; Levchenko, E V; Filochkina, A V; Arseniev, A I
2015-01-01
This review article analyzes data of literature devoted to the description, interpretation and classification of focal (nodal) changes in the lungs detected by computed tomography of the chest cavity. There are discussed possible criteria for determining the most likely of their character--primary and metastatic tumor processes, inflammation, scarring, and autoimmune changes, tuberculosis and others. Identification of the most characteristic, reliable and statistically significant evidences of a variety of pathological processes in the lungs including the use of modern computer-aided detection and diagnosis of sites will optimize the diagnostic measures and ensure processing of a large volume of medical data in a short time.
Evolutionary fuzzy modeling human diagnostic decisions.
Peña-Reyes, Carlos Andrés
2004-05-01
Fuzzy CoCo is a methodology, combining fuzzy logic and evolutionary computation, for constructing systems able to accurately predict the outcome of a human decision-making process, while providing an understandable explanation of the underlying reasoning. Fuzzy logic provides a formal framework for constructing systems exhibiting both good numeric performance (accuracy) and linguistic representation (interpretability). However, fuzzy modeling--meaning the construction of fuzzy systems--is an arduous task, demanding the identification of many parameters. To solve it, we use evolutionary computation techniques (specifically cooperative coevolution), which are widely used to search for adequate solutions in complex spaces. We have successfully applied the algorithm to model the decision processes involved in two breast cancer diagnostic problems, the WBCD problem and the Catalonia mammography interpretation problem, obtaining systems both of high performance and high interpretability. For the Catalonia problem, an evolved system was embedded within a Web-based tool-called COBRA-for aiding radiologists in mammography interpretation.
An Interrogative Model of Computer-Aided Adaptive Testing: Some Experimental Evidence
1988-09-01
Ahilitfas 2 Final 3g zj, research report, Office of Naval Research, Arlington, VA, June 1986. Brovn, 3. S. and Harris, a., " Artificial Intelligence and...Building an Intellegent Tutoring System," in Methods and Tactics in Cggnitive Science (Rds. Kintsch, Miller, and Poison), Lavrence Zrlbaum Associates...Education, Washington, DC, November 1984. 89 -7- In SIvasankaran, T. R. and Bul, Tung X., "A Bayesian Diagnostic Model for Intellegent CAI Systems
NASA Astrophysics Data System (ADS)
Lunt, T.; Fuchs, J. C.; Mank, K.; Feng, Y.; Brochard, F.; Herrmann, A.; Rohde, V.; Endstrasser, N.; ASDEX Upgrade Team
2010-11-01
A generally available and easy-to-use viewer for the simultaneous visualisation of the ASDEX Upgrade vacuum vessel computer aided design models, diagnostics and magnetic geometry, solutions of 3D plasma simulation codes and 2D camera images was developed. Here we report on the working principle of this software and give several examples of its technical and scientific application.
Deguchi, Shinji; Kawashima, Kazutaka; Washio, Seiichi
2008-12-01
The effect of artificially altered transglottal pressures on the voice fundamental frequency (F0) is known to be associated with vocal fold stiffness. Its measurement, though useful as a potential diagnostic tool for noncontact assessment of vocal fold stiffness, often requires manual and painstaking determination of an unstable F0 of voice. Here, we provide a computer-aided technique that enables one to carry out the determination easily and accurately. Human subjects vocalized in accordance with a series of reference sounds from a speaker controlled by a computer. Transglottal pressures were altered by means of a valve embedded in a mouthpiece. Time-varying vocal F0 was extracted, without manual procedures, from a specific range of the voice spectrum determined on the basis of the controlled reference sounds. The validity of the proposed technique was assessed for 11 healthy subjects. Fluctuating voice F0 was tracked automatically during experiments, providing the relationship between transglottal pressure change and F0 on the computer. The proposed technique overcomes the difficulty in automatic determination of the voice F0, which tends to be transient both in normal voice and in some types of pathological voice.
FTDD973: A multimedia knowledge-based system and methodology for operator training and diagnostics
NASA Technical Reports Server (NTRS)
Hekmatpour, Amir; Brown, Gary; Brault, Randy; Bowen, Greg
1993-01-01
FTDD973 (973 Fabricator Training, Documentation, and Diagnostics) is an interactive multimedia knowledge based system and methodology for computer-aided training and certification of operators, as well as tool and process diagnostics in IBM's CMOS SGP fabrication line (building 973). FTDD973 is an example of what can be achieved with modern multimedia workstations. Knowledge-based systems, hypertext, hypergraphics, high resolution images, audio, motion video, and animation are technologies that in synergy can be far more useful than each by itself. FTDD973's modular and object-oriented architecture is also an example of how improvements in software engineering are finally making it possible to combine many software modules into one application. FTDD973 is developed in ExperMedia/2; and OS/2 multimedia expert system shell for domain experts.
Djukic, Tijana; Mandic, Vesna; Filipovic, Nenad
2013-12-01
Medical education, training and preoperative diagnostics can be drastically improved with advanced technologies, such as virtual reality. The method proposed in this paper enables medical doctors and students to visualize and manipulate three-dimensional models created from CT or MRI scans, and also to analyze the results of fluid flow simulations. Simulation of fluid flow using the finite element method is performed, in order to compute the shear stress on the artery walls. The simulation of motion through the artery is also enabled. The virtual reality system proposed here could shorten the length of training programs and make the education process more effective. © 2013 Published by Elsevier Ltd.
Application of infrared thermography in computer aided diagnosis
NASA Astrophysics Data System (ADS)
Faust, Oliver; Rajendra Acharya, U.; Ng, E. Y. K.; Hong, Tan Jen; Yu, Wenwei
2014-09-01
The invention of thermography, in the 1950s, posed a formidable problem to the research community: What is the relationship between disease and heat radiation captured with Infrared (IR) cameras? The research community responded with a continuous effort to find this crucial relationship. This effort was aided by advances in processing techniques, improved sensitivity and spatial resolution of thermal sensors. However, despite this progress fundamental issues with this imaging modality still remain. The main problem is that the link between disease and heat radiation is complex and in many cases even non-linear. Furthermore, the change in heat radiation as well as the change in radiation pattern, which indicate disease, is minute. On a technical level, this poses high requirements on image capturing and processing. On a more abstract level, these problems lead to inter-observer variability and on an even more abstract level they lead to a lack of trust in this imaging modality. In this review, we adopt the position that these problems can only be solved through a strict application of scientific principles and objective performance assessment. Computing machinery is inherently objective; this helps us to apply scientific principles in a transparent way and to assess the performance results. As a consequence, we aim to promote thermography based Computer-Aided Diagnosis (CAD) systems. Another benefit of CAD systems comes from the fact that the diagnostic accuracy is linked to the capability of the computing machinery and, in general, computers become ever more potent. We predict that a pervasive application of computers and networking technology in medicine will help us to overcome the shortcomings of any single imaging modality and this will pave the way for integrated health care systems which maximize the quality of patient care.
Recent development on computer aided tissue engineering--a review.
Sun, Wei; Lal, Pallavi
2002-02-01
The utilization of computer-aided technologies in tissue engineering has evolved in the development of a new field of computer-aided tissue engineering (CATE). This article reviews recent development and application of enabling computer technology, imaging technology, computer-aided design and computer-aided manufacturing (CAD and CAM), and rapid prototyping (RP) technology in tissue engineering, particularly, in computer-aided tissue anatomical modeling, three-dimensional (3-D) anatomy visualization and 3-D reconstruction, CAD-based anatomical modeling, computer-aided tissue classification, computer-aided tissue implantation and prototype modeling assisted surgical planning and reconstruction.
Evaluation of image compression for computer-aided diagnosis of breast tumors in 3D sonography
NASA Astrophysics Data System (ADS)
Chen, We-Min; Huang, Yu-Len; Tao, Chi-Chuan; Chen, Dar-Ren; Moon, Woo-Kyung
2006-03-01
Medical imaging examinations form the basis for physicians diagnosing diseases, as evidenced by the increasing use of digital medical images for picture archiving and communications systems (PACS). However, with enlarged medical image databases and rapid growth of patients' case reports, PACS requires image compression to accelerate the image transmission rate and conserve disk space for diminishing implementation costs. For this purpose, JPEG and JPEG2000 have been accepted as legal formats for the digital imaging and communications in medicine (DICOM). The high compression ratio is felt to be useful for medical imagery. Therefore, this study evaluates the compression ratios of JPEG and JPEG2000 standards for computer-aided diagnosis (CAD) of breast tumors in 3-D medical ultrasound (US) images. The 3-D US data sets with various compression ratios are compressed using the two efficacious image compression standards. The reconstructed data sets are then diagnosed by a previous proposed CAD system. The diagnostic accuracy is measured based on receiver operating characteristic (ROC) analysis. Namely, the ROC curves are used to compare the diagnostic performance of two or more reconstructed images. Analysis results ensure a comparison of the compression ratios by using JPEG and JPEG2000 for 3-D US images. Results of this study provide the possible bit rates using JPEG and JPEG2000 for 3-D breast US images.
Short-Term Outcomes of Screening Mammography Using Computer-Aided Detection
Fenton, Joshua J.; Xing, Guibo; Elmore, Joann G.; Bang, Heejung; Chen, Steven L.; Lindfors, Karen K.; Baldwin, Laura-Mae
2013-01-01
Background Computer-aided detection (CAD) has rapidly diffused into screening mammography practice despite limited and conflicting data on its clinical effect. Objective To determine associations between CAD use during screening mammography and the incidence of ductal carcinoma in situ (DCIS) and invasive breast cancer, invasive cancer stage, and diagnostic testing. Design Retrospective cohort study. Setting Medicare program. Participants Women aged 67 to 89 years having screening mammography between 2001 and 2006 in U.S. SEER (Surveillance, Epidemiology and End Results) regions (409 459 mammograms from 163 099 women). Measurements Incident DCIS and invasive breast cancer within 1 year after mammography, invasive cancer stage, and diagnostic testing within 90 days after screening among women without breast cancer. Results From 2001 to 2006, CAD prevalence increased from 3.6% to 60.5%. Use of CAD was associated with greater DCIS incidence (adjusted odds ratio [OR], 1.17 [95% CI, 1.11 to 1.23]) but no difference in invasive breast cancer incidence (adjusted OR, 1.00 [CI, 0.97 to 1.03]). Among women with invasive cancer, CAD was associated with greater likelihood of stage I to II versus III to IV cancer (adjusted OR, 1.27 [CI, 1.14 to 1.41]). In women without breast cancer, CAD was associated with increased odds of diagnostic mammography (adjusted OR, 1.28 [CI, 1.27 to 1.29]), breast ultrasonography (adjusted OR, 1.07 [CI, 1.06 to 1.09]), and breast biopsy (adjusted OR, 1.10 [CI, 1.08 to 1.12]). Limitation Short follow-up for cancer stage, potential unmeasured confounding, and uncertain generalizability to younger women. Conclusion Use of CAD during screening mammography among Medicare enrollees is associated with increased DCIS incidence, the diagnosis of invasive breast cancer at earlier stages, and increased diagnostic testing among women without breast cancer. Primary Funding Source Center for Healthcare Policy and Research, University of California, Davis. PMID:23588746
NASA Astrophysics Data System (ADS)
Jevtić, Dubravka R.; Avramov Ivić, Milka L.; Reljin, Irini S.; Reljin, Branimir D.; Plavec, Goran I.; Petrović, Slobodan D.; Mijin, Dušan Ž.
2014-06-01
The automated, computer-aided method for differentiation and classification of malignant (M) from benign (B) cases, by analyzing the UV/VIS spectra of pleural effusions is described. It was shown that by two independent objective features, the maximum of Katz fractal dimension (KFDmax) and the area under normalized UV/VIS absorbance curve (Area), highly reliable M-B classification is possible. In the Area-KFDmax space M and B samples are linearly separable permitting thus the use of linear support vector machine as a classification tool. By analyzing 104 samples of UV/VIS spectra of pleural effusions (88 M and 16 B) collected from patients at the Clinic for Lung Diseases and Tuberculosis, Military Medical Academy in Belgrade, the accuracy of 95.45% for M cases and 100% for B cases are obtained by using the proposed method. It was shown that by applying some modifications, which are suggested in the paper, the accuracy of 100% for M cases can be reached.
Gao, Luying; Liu, Ruyu; Jiang, Yuxin; Song, Wenfeng; Wang, Ying; Liu, Jia; Wang, Juanjuan; Wu, Dongqian; Li, Shuai; Hao, Aimin; Zhang, Bo
2018-04-01
The purpose of this study was to compare the diagnostic efficiency of a thyroid ultrasound computer-aided diagnosis (CAD) system with that of 1 radiologist. This study retrospectively reviewed 342 surgically resected thyroid nodules from July 2013 to December 2013 at our center. The nodules were assessed on typical ultrasound images using the CAD system and reviewed by 1 experienced radiologist. The radiologist stratified the risk of malignancy using the Thyroid Imaging Reporting and Data Systems (TIRADS) and the American Thyroid Association (ATA) guidelines. The radiologist, using TI-RADS and ATA guidelines, performed better than the CAD system (P < .01). The sensitivity of the CAD system was similar to that of an experienced radiologist (P > .05; P < .01; and P > .05). However, we found that the CAD system had lower specificity (P < .01). The sensitivity of a thyroid ultrasound CAD system in differentiating nodules was similar to that of an experienced radiologist. However, the CAD system had lower specificity. © 2017 Wiley Periodicals, Inc.
An evaluation of computer-aided disproportionality analysis for post-marketing signal detection.
Lehman, H P; Chen, J; Gould, A L; Kassekert, R; Beninger, P R; Carney, R; Goldberg, M; Goss, M A; Kidos, K; Sharrar, R G; Shields, K; Sweet, A; Wiholm, B E; Honig, P K
2007-08-01
To understand the value of computer-aided disproportionality analysis (DA) in relation to current pharmacovigilance signal detection methods, four products were retrospectively evaluated by applying an empirical Bayes method to Merck's post-marketing safety database. Findings were compared with the prior detection of labeled post-marketing adverse events. Disproportionality ratios (empirical Bayes geometric mean lower 95% bounds for the posterior distribution (EBGM05)) were generated for product-event pairs. Overall (1993-2004 data, EBGM05> or =2, individual terms) results of signal detection using DA compared to standard methods were sensitivity, 31.1%; specificity, 95.3%; and positive predictive value, 19.9%. Using groupings of synonymous labeled terms, sensitivity improved (40.9%). More of the adverse events detected by both methods were detected earlier using DA and grouped (versus individual) terms. With 1939-2004 data, diagnostic properties were similar to those from 1993 to 2004. DA methods using Merck's safety database demonstrate sufficient sensitivity and specificity to be considered for use as an adjunct to conventional signal detection methods.
Breast Histopathological Image Retrieval Based on Latent Dirichlet Allocation.
Ma, Yibing; Jiang, Zhiguo; Zhang, Haopeng; Xie, Fengying; Zheng, Yushan; Shi, Huaqiang; Zhao, Yu
2017-07-01
In the field of pathology, whole slide image (WSI) has become the major carrier of visual and diagnostic information. Content-based image retrieval among WSIs can aid the diagnosis of an unknown pathological image by finding its similar regions in WSIs with diagnostic information. However, the huge size and complex content of WSI pose several challenges for retrieval. In this paper, we propose an unsupervised, accurate, and fast retrieval method for a breast histopathological image. Specifically, the method presents a local statistical feature of nuclei for morphology and distribution of nuclei, and employs the Gabor feature to describe the texture information. The latent Dirichlet allocation model is utilized for high-level semantic mining. Locality-sensitive hashing is used to speed up the search. Experiments on a WSI database with more than 8000 images from 15 types of breast histopathology demonstrate that our method achieves about 0.9 retrieval precision as well as promising efficiency. Based on the proposed framework, we are developing a search engine for an online digital slide browsing and retrieval platform, which can be applied in computer-aided diagnosis, pathology education, and WSI archiving and management.
Computer-aided diagnosis and artificial intelligence in clinical imaging.
Shiraishi, Junji; Li, Qiang; Appelbaum, Daniel; Doi, Kunio
2011-11-01
Computer-aided diagnosis (CAD) is rapidly entering the radiology mainstream. It has already become a part of the routine clinical work for the detection of breast cancer with mammograms. The computer output is used as a "second opinion" in assisting radiologists' image interpretations. The computer algorithm generally consists of several steps that may include image processing, image feature analysis, and data classification via the use of tools such as artificial neural networks (ANN). In this article, we will explore these and other current processes that have come to be referred to as "artificial intelligence." One element of CAD, temporal subtraction, has been applied for enhancing interval changes and for suppressing unchanged structures (eg, normal structures) between 2 successive radiologic images. To reduce misregistration artifacts on the temporal subtraction images, a nonlinear image warping technique for matching the previous image to the current one has been developed. Development of the temporal subtraction method originated with chest radiographs, with the method subsequently being applied to chest computed tomography (CT) and nuclear medicine bone scans. The usefulness of the temporal subtraction method for bone scans was demonstrated by an observer study in which reading times and diagnostic accuracy improved significantly. An additional prospective clinical study verified that the temporal subtraction image could be used as a "second opinion" by radiologists with negligible detrimental effects. ANN was first used in 1990 for computerized differential diagnosis of interstitial lung diseases in CAD. Since then, ANN has been widely used in CAD schemes for the detection and diagnosis of various diseases in different imaging modalities, including the differential diagnosis of lung nodules and interstitial lung diseases in chest radiography, CT, and position emission tomography/CT. It is likely that CAD will be integrated into picture archiving and communication systems and will become a standard of care for diagnostic examinations in daily clinical work. Copyright © 2011 Elsevier Inc. All rights reserved.
ACER Physics Unit Tests: Unit Tests, Diagnostic Aids, [and] Teachers Handbook.
ERIC Educational Resources Information Center
Australian Council for Educational Research, Hawthorn.
The Physics Unit Tests are designed to assist in the diagnostic evaluation of students' progress in the study of physics during the last two years of secondary schooling. They consist of a collection of 21 separate tests, each related to a different topic, and 21 diagnostic aids corresponding to the tests. The topics covered are: physical…
A CLIPS based personal computer hardware diagnostic system
NASA Technical Reports Server (NTRS)
Whitson, George M.
1991-01-01
Often the person designated to repair personal computers has little or no knowledge of how to repair a computer. Described here is a simple expert system to aid these inexperienced repair people. The first component of the system leads the repair person through a number of simple system checks such as making sure that all cables are tight and that the dip switches are set correctly. The second component of the system assists the repair person in evaluating error codes generated by the computer. The final component of the system applies a large knowledge base to attempt to identify the component of the personal computer that is malfunctioning. We have implemented and tested our design with a full system to diagnose problems for an IBM compatible system based on the 8088 chip. In our tests, the inexperienced repair people found the system very useful in diagnosing hardware problems.
A Clinicopathological Study of Various Oral Cancer Diagnostic Techniques
Ulaganathan, G.; Mohamed Niazi, K. Thanvir; Srinivasan, Soundarya; Balaji, V. R.; Manikandan, D.; Hameed, K. A. Shahul; Banumathi, A.
2017-01-01
Oral cancer is one of the most commonly occurring malignant tumors in the head and neck regions with high incident rate and mortality rate in the developed countries than in the developing countries. Generally, the survival rate of cancer patients may increase when diagnosed at early stage, followed by prompt treatment and therapy. Recently, cancer diagnosis and therapy design for a specific cancer patient have been performed with the advanced computer-aided techniques. The responses of the cancer therapy could be continuously monitored to ensure the effectiveness of the treatment process that hardly requires diagnostic result as quick as possible to improve the quality and patient care. This paper gives an overview of oral cancer occurrence, different types, and various diagnostic techniques. In addition, a brief introduction is given to various stages of immunoanalysis including tissue image preparation, whole slide imaging, and microscopic image analysis. PMID:29284926
Jieyi Li; Arandjelovic, Ognjen
2017-07-01
Computer science and machine learning in particular are increasingly lauded for their potential to aid medical practice. However, the highly technical nature of the state of the art techniques can be a major obstacle in their usability by health care professionals and thus, their adoption and actual practical benefit. In this paper we describe a software tool which focuses on the visualization of predictions made by a recently developed method which leverages data in the form of large scale electronic records for making diagnostic predictions. Guided by risk predictions, our tool allows the user to explore interactively different diagnostic trajectories, or display cumulative long term prognostics, in an intuitive and easily interpretable manner.
Baltzer, Pascal Andreas Thomas; Freiberg, Christian; Beger, Sebastian; Vag, Tibor; Dietzel, Matthias; Herzog, Aimee B; Gajda, Mieczyslaw; Camara, Oumar; Kaiser, Werner A
2009-09-01
Enhancement characteristics after administration of a contrast agent are regarded as a major criterion for differential diagnosis in magnetic resonance mammography (MRM). However, no consensus exists about the best measurement method to assess contrast enhancement kinetics. This systematic investigation was performed to compare visual estimation with manual region of interest (ROI) and computer-aided diagnosis (CAD) analysis for time curve measurements in MRM. A total of 329 patients undergoing surgery after MRM (1.5 T) were analyzed prospectively. Dynamic data were measured using visual estimation, including ROI as well as CAD methods, and classified depending on initial signal increase and delayed enhancement. Pathology revealed 469 lesions (279 malignant, 190 benign). Kappa agreement between the methods ranged from 0.78 to 0.81. Diagnostic accuracies of 74.4% (visual), 75.7% (ROI), and 76.6% (CAD) were found without statistical significant differences. According to our results, curve type measurements are useful as a diagnostic criterion in breast lesions irrespective of the method used.
[Computer-assisted phonetography as a diagnostic aid in functional dysphonia].
Airainer, R; Klingholz, F
1991-07-01
A total of 160 voice-trained and untrained subjects with functional dysphonia were given a "clinical rating" according to their clinical findings. This was a certain value on a scale that recorded the degree of functional voice disorder ranging from a marked hypofunction to an extreme hyperfunction. The phonetograms of these patients were approximated by ellipses, whereby the definition and quantitative recording of several phonetogram parameters were rendered possible. By means of a linear combination of phonetogram parameters, a "calculated assessment" was obtained for each patient that was expected to tally with the "clinical rating". This paper demonstrates that a graduation of the dysphonic clinical picture with regard to the presence of hypofunctional or hyperfunctional components is possible via computerised phonetogram evaluation. In this case, the "calculated assessments" for both male and female singers and non-singers must be computed using different linear combinations. The method can be introduced as a supplementary diagnostic procedure in the diagnosis of functional dysphonia.
Ben'kovich, B I; Gorshkova, I A; Gershanovich, I I; Faĭzulloev, A Z
2001-01-01
The paper presents a complex psychophysiological analysis of the effect of a combined administration of pantogam and potassium orotate (kalii orotas) on the dynamics of cognitive function in patients with neurotic disorders. The investigation was conducted in an 8-stage consecutive cycle and employed computer-aided diagnostic system. It was established that the combined use of pantogam and potassium orotate produces a positive effect upon the dynamics of restoration of the attention and memory mechanisms in neurotic patients.
NASA Astrophysics Data System (ADS)
André, M. P.; Galperin, M.; Berry, A.; Ojeda-Fournier, H.; O'Boyle, M.; Olson, L.; Comstock, C.; Taylor, A.; Ledgerwood, M.
Our computer-aided diagnostic (CADx) tool uses advanced image processing and artificial intelligence to analyze findings on breast sonography images. The goal is to standardize reporting of such findings using well-defined descriptors and to improve accuracy and reproducibility of interpretation of breast ultrasound by radiologists. This study examined several factors that may impact accuracy and reproducibility of the CADx software, which proved to be highly accurate and stabile over several operating conditions.
Pulmonary lobar volumetry using novel volumetric computer-aided diagnosis and computed tomography
Iwano, Shingo; Kitano, Mariko; Matsuo, Keiji; Kawakami, Kenichi; Koike, Wataru; Kishimoto, Mariko; Inoue, Tsutomu; Li, Yuanzhong; Naganawa, Shinji
2013-01-01
OBJECTIVES To compare the accuracy of pulmonary lobar volumetry using the conventional number of segments method and novel volumetric computer-aided diagnosis using 3D computed tomography images. METHODS We acquired 50 consecutive preoperative 3D computed tomography examinations for lung tumours reconstructed at 1-mm slice thicknesses. We calculated the lobar volume and the emphysematous lobar volume < −950 HU of each lobe using (i) the slice-by-slice method (reference standard), (ii) number of segments method, and (iii) semi-automatic and (iv) automatic computer-aided diagnosis. We determined Pearson correlation coefficients between the reference standard and the three other methods for lobar volumes and emphysematous lobar volumes. We also compared the relative errors among the three measurement methods. RESULTS Both semi-automatic and automatic computer-aided diagnosis results were more strongly correlated with the reference standard than the number of segments method. The correlation coefficients for automatic computer-aided diagnosis were slightly lower than those for semi-automatic computer-aided diagnosis because there was one outlier among 50 cases (2%) in the right upper lobe and two outliers among 50 cases (4%) in the other lobes. The number of segments method relative error was significantly greater than those for semi-automatic and automatic computer-aided diagnosis (P < 0.001). The computational time for automatic computer-aided diagnosis was 1/2 to 2/3 than that of semi-automatic computer-aided diagnosis. CONCLUSIONS A novel lobar volumetry computer-aided diagnosis system could more precisely measure lobar volumes than the conventional number of segments method. Because semi-automatic computer-aided diagnosis and automatic computer-aided diagnosis were complementary, in clinical use, it would be more practical to first measure volumes by automatic computer-aided diagnosis, and then use semi-automatic measurements if automatic computer-aided diagnosis failed. PMID:23526418
Computer-aided diagnosis of melanoma using border and wavelet-based texture analysis.
Garnavi, Rahil; Aldeen, Mohammad; Bailey, James
2012-11-01
This paper presents a novel computer-aided diagnosis system for melanoma. The novelty lies in the optimised selection and integration of features derived from textural, borderbased and geometrical properties of the melanoma lesion. The texture features are derived from using wavelet-decomposition, the border features are derived from constructing a boundaryseries model of the lesion border and analysing it in spatial and frequency domains, and the geometry features are derived from shape indexes. The optimised selection of features is achieved by using the Gain-Ratio method, which is shown to be computationally efficient for melanoma diagnosis application. Classification is done through the use of four classifiers; namely, Support Vector Machine, Random Forest, Logistic Model Tree and Hidden Naive Bayes. The proposed diagnostic system is applied on a set of 289 dermoscopy images (114 malignant, 175 benign) partitioned into train, validation and test image sets. The system achieves and accuracy of 91.26% and AUC value of 0.937, when 23 features are used. Other important findings include (i) the clear advantage gained in complementing texture with border and geometry features, compared to using texture information only, and (ii) higher contribution of texture features than border-based features in the optimised feature set.
ERIC Educational Resources Information Center
Ickenroth, Martine H. P.; Grispen, J. E. J.; de Vries, N. K.; Dinant, G. J.; Ronda, G.; van der Weijden, T.
2016-01-01
Currently, there are many diagnostic self-tests on body materials available to consumers. The aim of this study was to assess the effect of an online decision aid on diagnostic self-testing for cholesterol and diabetes on knowledge among consumers with an intention to take these tests. A randomized controlled trial was designed. A total of 1259…
Reduction of bias and variance for evaluation of computer-aided diagnostic schemes.
Li, Qiang; Doi, Kunio
2006-04-01
Computer-aided diagnostic (CAD) schemes have been developed to assist radiologists in detecting various lesions in medical images. In addition to the development, an equally important problem is the reliable evaluation of the performance levels of various CAD schemes. It is good to see that more and more investigators are employing more reliable evaluation methods such as leave-one-out and cross validation, instead of less reliable methods such as resubstitution, for assessing their CAD schemes. However, the common applications of leave-one-out and cross-validation evaluation methods do not necessarily imply that the estimated performance levels are accurate and precise. Pitfalls often occur in the use of leave-one-out and cross-validation evaluation methods, and they lead to unreliable estimation of performance levels. In this study, we first identified a number of typical pitfalls for the evaluation of CAD schemes, and conducted a Monte Carlo simulation experiment for each of the pitfalls to demonstrate quantitatively the extent of bias and/or variance caused by the pitfall. Our experimental results indicate that considerable bias and variance may exist in the estimated performance levels of CAD schemes if one employs various flawed leave-one-out and cross-validation evaluation methods. In addition, for promoting and utilizing a high standard for reliable evaluation of CAD schemes, we attempt to make recommendations, whenever possible, for overcoming these pitfalls. We believe that, with the recommended evaluation methods, we can considerably reduce the bias and variance in the estimated performance levels of CAD schemes.
Rajaraman, Sivaramakrishnan; Antani, Sameer K; Poostchi, Mahdieh; Silamut, Kamolrat; Hossain, Md A; Maude, Richard J; Jaeger, Stefan; Thoma, George R
2018-01-01
Malaria is a blood disease caused by the Plasmodium parasites transmitted through the bite of female Anopheles mosquito. Microscopists commonly examine thick and thin blood smears to diagnose disease and compute parasitemia. However, their accuracy depends on smear quality and expertise in classifying and counting parasitized and uninfected cells. Such an examination could be arduous for large-scale diagnoses resulting in poor quality. State-of-the-art image-analysis based computer-aided diagnosis (CADx) methods using machine learning (ML) techniques, applied to microscopic images of the smears using hand-engineered features demand expertise in analyzing morphological, textural, and positional variations of the region of interest (ROI). In contrast, Convolutional Neural Networks (CNN), a class of deep learning (DL) models promise highly scalable and superior results with end-to-end feature extraction and classification. Automated malaria screening using DL techniques could, therefore, serve as an effective diagnostic aid. In this study, we evaluate the performance of pre-trained CNN based DL models as feature extractors toward classifying parasitized and uninfected cells to aid in improved disease screening. We experimentally determine the optimal model layers for feature extraction from the underlying data. Statistical validation of the results demonstrates the use of pre-trained CNNs as a promising tool for feature extraction for this purpose.
[Medical expert systems and clinical needs].
Buscher, H P
1991-10-18
The rapid expansion of computer-based systems for problem solving or decision making in medicine, the so-called medical expert systems, emphasize the need for reappraisal of their indication and value. Where specialist knowledge is required, in particular where medical decisions are susceptible to error these systems will probably serve as a valuable support. In the near future computer-based systems should be able to aid the interpretation of findings of technical investigations and the control of treatment, especially where rapid reactions are necessary despite the need of complex analysis of investigated parameters. In the distant future complete support of diagnostic procedures from the history to final diagnosis is possible. It promises to be particularly attractive for the diagnosis of seldom diseases, for difficult differential diagnoses, and in the decision making in the case of expensive, risky or new diagnostic or therapeutic methods. The physician needs to be aware of certain dangers, ranging from misleading information up to abuse. Patient information depends often on subjective reports and error-prone observations. Although basing on problematic knowledge computer-born decisions may have an imperative effect on medical decision making. Also it must be born in mind that medical decisions should always combine the rational with a consideration of human motives.
NASA Technical Reports Server (NTRS)
Schwartz, Richard J.; Fleming, Gary A.
2007-01-01
Virtual Diagnostics Interface technology, or ViDI, is a suite of techniques utilizing image processing, data handling and three-dimensional computer graphics. These techniques aid in the design, implementation, and analysis of complex aerospace experiments. LiveView3D is a software application component of ViDI used to display experimental wind tunnel data in real-time within an interactive, three-dimensional virtual environment. The LiveView3D software application was under development at NASA Langley Research Center (LaRC) for nearly three years. LiveView3D recently was upgraded to perform real-time (as well as post-test) comparisons of experimental data with pre-computed Computational Fluid Dynamics (CFD) predictions. This capability was utilized to compare experimental measurements with CFD predictions of the surface pressure distribution of the NASA Ares I Crew Launch Vehicle (CLV) - like vehicle when tested in the NASA LaRC Unitary Plan Wind Tunnel (UPWT) in December 2006 - January 2007 timeframe. The wind tunnel tests were conducted to develop a database of experimentally-measured aerodynamic performance of the CLV-like configuration for validation of CFD predictive codes.
Computer-based diagnostic decisionmaking.
Miller, R A
1987-12-01
The three decisionmaking aids described by the authors attack the generic problem of "see no evil, hear no evil, speak no evil"--improving the detection, diagnosis, and therapy of psychiatric disorders in the primary care setting. The three systems represent interventions at different steps in the process of providing appropriate care to psychiatric patients. The DSPW system of Robins and Marcus offers the potential of increasing the recognition of psychiatric disease in the physician's office. Politser's IDS program is representative of the sort of sophisticated microcomputer-based decisionmaking support tools that will become available to physicians in the not-too-distant future. Erdman's study of the impact of explanation capabilities on the acceptability of therapy recommending systems points out the need for careful scientific evaluations of features added to diagnostic and therapeutic systems.
2001-09-01
The high-tech art of digital signal processing (DSP) was pioneered at NASA's Jet Propulsion Laboratory (JPL) in the mid-1960s for use in the Apollo Lunar Landing Program. Designed to computer enhance pictures of the Moon, this technology became the basis for the Landsat Earth resources satellites and subsequently has been incorporated into a broad range of Earthbound medical and diagnostic tools. DSP is employed in advanced body imaging techniques including Computer-Aided Tomography, also known as CT and CATScan, and Magnetic Resonance Imaging (MRI). CT images are collected by irradiating a thin slice of the body with a fan-shaped x-ray beam from a number of directions around the body's perimeter. A tomographic (slice-like) picture is reconstructed from these multiple views by a computer. MRI employs a magnetic field and radio waves, rather than x-rays, to create images.
Coy, Heidi; Young, Jonathan R; Douek, Michael L; Brown, Matthew S; Sayre, James; Raman, Steven S
2017-07-01
To evaluate the performance of a novel, quantitative computer-aided diagnostic (CAD) algorithm on four-phase multidetector computed tomography (MDCT) to detect peak lesion attenuation to enable differentiation of clear cell renal cell carcinoma (ccRCC) from chromophobe RCC (chRCC), papillary RCC (pRCC), oncocytoma, and fat-poor angiomyolipoma (fp-AML). We queried our clinical databases to obtain a cohort of histologically proven renal masses with preoperative MDCT with four phases [unenhanced (U), corticomedullary (CM), nephrographic (NP), and excretory (E)]. A whole lesion 3D contour was obtained in all four phases. The CAD algorithm determined a region of interest (ROI) of peak lesion attenuation within the 3D lesion contour. For comparison, a manual ROI was separately placed in the most enhancing portion of the lesion by visual inspection for a reference standard, and in uninvolved renal cortex. Relative lesion attenuation for both CAD and manual methods was obtained by normalizing the CAD peak lesion attenuation ROI (and the reference standard manually placed ROI) to uninvolved renal cortex with the formula [(peak lesion attenuation ROI - cortex ROI)/cortex ROI] × 100%. ROC analysis and area under the curve (AUC) were used to assess diagnostic performance. Bland-Altman analysis was used to compare peak ROI between CAD and manual method. The study cohort comprised 200 patients with 200 unique renal masses: 106 (53%) ccRCC, 32 (16%) oncocytomas, 18 (9%) chRCCs, 34 (17%) pRCCs, and 10 (5%) fp-AMLs. In the CM phase, CAD-derived ROI enabled characterization of ccRCC from chRCC, pRCC, oncocytoma, and fp-AML with AUCs of 0.850 (95% CI 0.732-0.968), 0.959 (95% CI 0.930-0.989), 0.792 (95% CI 0.716-0.869), and 0.825 (95% CI 0.703-0.948), respectively. On Bland-Altman analysis, there was excellent agreement of CAD and manual methods with mean differences between 14 and 26 HU in each phase. A novel, quantitative CAD algorithm enabled robust peak HU lesion detection and discrimination of ccRCC from other renal lesions with similar performance compared to the manual method.
Source Book of Educational Materials for Diagnostic Medical Ultrasound. Radiological Health Series.
ERIC Educational Resources Information Center
Pijar, Mary Lou, Comp; And Others
This report is a compilation of educational materials that are available in the field of diagnostic medical ultrasound. Materials, which include publications, audiovisual aids, and teaching aids, are listed under the following categories: abdominal imaging; anatomy and physiology; anatomy and embryology; bioeffects; cardiology and vasculature;…
Modeling paradigms for medical diagnostic decision support: a survey and future directions.
Wagholikar, Kavishwar B; Sundararajan, Vijayraghavan; Deshpande, Ashok W
2012-10-01
Use of computer based decision tools to aid clinical decision making, has been a primary goal of research in biomedical informatics. Research in the last five decades has led to the development of Medical Decision Support (MDS) applications using a variety of modeling techniques, for a diverse range of medical decision problems. This paper surveys literature on modeling techniques for diagnostic decision support, with a focus on decision accuracy. Trends and shortcomings of research in this area are discussed and future directions are provided. The authors suggest that-(i) Improvement in the accuracy of MDS application may be possible by modeling of vague and temporal data, research on inference algorithms, integration of patient information from diverse sources and improvement in gene profiling algorithms; (ii) MDS research would be facilitated by public release of de-identified medical datasets, and development of opensource data-mining tool kits; (iii) Comparative evaluations of different modeling techniques are required to understand characteristics of the techniques, which can guide developers in choice of technique for a particular medical decision problem; and (iv) Evaluations of MDS applications in clinical setting are necessary to foster physicians' utilization of these decision aids.
Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey
Zhang, Fan; Li, Xuelong
2018-01-01
The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system. PMID:29687000
Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey.
Huang, Qinghua; Zhang, Fan; Li, Xuelong
2018-01-01
The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.
Water transport in limestone by X-ray CAT scanning
Mossoti, Victor G.; Castanier, Louis M.
1989-01-01
The transport of water through the interior of Salem limestone test briquettes can be dynamically monitored by computer aided tomography (commonly called CAT scanning in medical diagnostics). Most significantly, unless evaporation from a particular face of the briquette is accelerated by forced air flow (wind simulation), the distribution of water in the interior of the briquette remains more or less uniform throughout the complete drying cycle. Moreover, simulated solar illumination of the test briquette does not result in the production of significant water gradients in the briquette under steady-state drying conditions.
Prinz, I; Nubel, K; Gross, M
2002-09-01
Until now, the assumed benefits of digital hearing aids are reflected only in subjective descriptions by patients with hearing aids, but cannot be documented adequately by routine diagnostic methods. Seventeen schoolchildren with moderate severe bilateral symmetrical sensorineural hearing loss were examined in a double-blinded crossover study. Differences in performance between a fully digital hearing aid (DigiFocus compact/Oticon) and an analogous digitally programmable two-channel hearing aid were evaluated. Of the 17 children, 13 choose the digital and 4 the analogous hearing aid. In contrast to the clear subjective preferences for the fully digital hearing aid, we could not obtain any significant results with routine diagnostic methods. Using the "virtual hearing aid," a subjective comparison and speech recognition performance task yielded significant differences. The virtual hearing aid proved to be suitable for a direct comparison of different hearing aids and can be used for double-blind testing in a pediatric population.
NASA Astrophysics Data System (ADS)
Xu, Ye; Lee, Michael C.; Boroczky, Lilla; Cann, Aaron D.; Borczuk, Alain C.; Kawut, Steven M.; Powell, Charles A.
2009-02-01
Features calculated from different dimensions of images capture quantitative information of the lung nodules through one or multiple image slices. Previously published computer-aided diagnosis (CADx) systems have used either twodimensional (2D) or three-dimensional (3D) features, though there has been little systematic analysis of the relevance of the different dimensions and of the impact of combining different dimensions. The aim of this study is to determine the importance of combining features calculated in different dimensions. We have performed CADx experiments on 125 pulmonary nodules imaged using multi-detector row CT (MDCT). The CADx system computed 192 2D, 2.5D, and 3D image features of the lesions. Leave-one-out experiments were performed using five different combinations of features from different dimensions: 2D, 3D, 2.5D, 2D+3D, and 2D+3D+2.5D. The experiments were performed ten times for each group. Accuracy, sensitivity and specificity were used to evaluate the performance. Wilcoxon signed-rank tests were applied to compare the classification results from these five different combinations of features. Our results showed that 3D image features generate the best result compared with other combinations of features. This suggests one approach to potentially reducing the dimensionality of the CADx data space and the computational complexity of the system while maintaining diagnostic accuracy.
Relevance of deep learning to facilitate the diagnosis of HER2 status in breast cancer
NASA Astrophysics Data System (ADS)
Vandenberghe, Michel E.; Scott, Marietta L. J.; Scorer, Paul W.; Söderberg, Magnus; Balcerzak, Denis; Barker, Craig
2017-04-01
Tissue biomarker scoring by pathologists is central to defining the appropriate therapy for patients with cancer. Yet, inter-pathologist variability in the interpretation of ambiguous cases can affect diagnostic accuracy. Modern artificial intelligence methods such as deep learning have the potential to supplement pathologist expertise to ensure constant diagnostic accuracy. We developed a computational approach based on deep learning that automatically scores HER2, a biomarker that defines patient eligibility for anti-HER2 targeted therapies in breast cancer. In a cohort of 71 breast tumour resection samples, automated scoring showed a concordance of 83% with a pathologist. The twelve discordant cases were then independently reviewed, leading to a modification of diagnosis from initial pathologist assessment for eight cases. Diagnostic discordance was found to be largely caused by perceptual differences in assessing HER2 expression due to high HER2 staining heterogeneity. This study provides evidence that deep learning aided diagnosis can facilitate clinical decision making in breast cancer by identifying cases at high risk of misdiagnosis.
New Diagnostic Aides for Melanoma
Ferris, Laura K.; Harris, Ryan J.
2012-01-01
Synopsis Detection of melanoma at an early stage is crucial to improving survival rates in melanoma. Accurate diagnosis by current techniques including dermatoscopy remains difficult, and new tools are needed to improve our diagnostic abilities. This article discusses recent advances in diagnostic techniques including confocal scanning laser microscopy, MelaFind, Siascopy, noninvasive genomic detection, as well as other future possibilities to aid in diagnosing melanoma. Advantages and barriers to implementation of the various technologies are discussed as well. PMID:22800557
Seruya, Mitchel; Fisher, Mark; Rodriguez, Eduardo D
2013-11-01
There has been rising interest in computer-aided design/computer-aided manufacturing for preoperative planning and execution of osseous free flap reconstruction. The purpose of this study was to compare outcomes between computer-assisted and conventional fibula free flap techniques for craniofacial reconstruction. A two-center, retrospective review was carried out on patients who underwent fibula free flap surgery for craniofacial reconstruction from 2003 to 2012. Patients were categorized by the type of reconstructive technique: conventional (between 2003 and 2009) or computer-aided design/computer-aided manufacturing (from 2010 to 2012). Demographics, surgical factors, and perioperative and long-term outcomes were compared. A total of 68 patients underwent microsurgical craniofacial reconstruction: 58 conventional and 10 computer-aided design and manufacturing fibula free flaps. By demographics, patients undergoing the computer-aided design/computer-aided manufacturing method were significantly older and had a higher rate of radiotherapy exposure compared with conventional patients. Intraoperatively, the median number of osteotomies was significantly higher (2.0 versus 1.0, p=0.002) and the median ischemia time was significantly shorter (120 minutes versus 170 minutes, p=0.004) for the computer-aided design/computer-aided manufacturing technique compared with conventional techniques; operative times were shorter for patients undergoing the computer-aided design/computer-aided manufacturing technique, although this did not reach statistical significance. Perioperative and long-term outcomes were equivalent for the two groups, notably, hospital length of stay, recipient-site infection, partial and total flap loss, and rate of soft-tissue and bony tissue revisions. Microsurgical craniofacial reconstruction using a computer-assisted fibula flap technique yielded significantly shorter ischemia times amidst a higher number of osteotomies compared with conventional techniques. Therapeutic, III.
Experimental and computational data from a small rocket exhaust diffuser
NASA Astrophysics Data System (ADS)
Stephens, Samuel E.
1993-06-01
The Diagnostics Testbed Facility (DTF) at the NASA Stennis Space Center in Mississippi is a versatile facility that is used primarily to aid in the development of nonintrusive diagnostics for liquid rocket engine testing. The DTF consists of a fixed, 1200 lbf thrust, pressure fed, liquid oxygen/gaseous hydrogen rocket engine, and associated support systems. An exhaust diffuser has been fabricated and installed to provide subatmospheric pressures at the exit of the engine. The diffuser aerodynamic design was calculated prior to fabrication using the PARC Navier-Stokes computational fluid dynamics code. The diffuser was then fabricated and tested at the DTF. Experimental data from these tests were acquired to determine the operational characteristics of the system and to correlate the actual and predicted flow fields. The results show that a good engineering approximation of overall diffuser performance can be made using the PARC Navier-Stokes code and a simplified geometry. Correlations between actual and predicted cell pressure and initial plume expansion in the diffuser are good; however, the wall pressure profiles do not correlate as well with the experimental data.
A Diagnostic/Prescriptive System to Aid in the Treatment of Behavioral Disorders.
ERIC Educational Resources Information Center
Cunningham, William G.; And Others
Described is the development of a diagnostic/prescriptive system--developed as part of the Pendleton Project--which would aid in the understanding of causes and ultimate treatment of dysfunctional behavior in 6- through 12-year-old children. Reported are the objectives and rationale of the Pendleton Project, an interdisciplinary, community based…
Computers in medicine: liability issues for physicians.
Hafner, A W; Filipowicz, A B; Whitely, W P
1989-07-01
Physicians routinely use computers to store, access, and retrieve medical information. As computer use becomes even more widespread in medicine, failure to utilize information systems may be seen as a violation of professional custom and lead to findings of professional liability. Even when a technology is not widespread, failure to incorporate it into medical practice may give rise to liability if the technology is accessible to the physician and reduces risk to the patient. Improvement in the availability of medical information sources imposes a greater burden on the physician to keep current and to obtain informed consent from patients. To routinely perform computer-assisted literature searches for informed consent and diagnosis is 'good medicine'. Clinical and diagnostic applications of computer technology now include computer-assisted decision making with the aid of sophisticated databases. Although such systems will expand the knowledge base and competence of physicians, malfunctioning software raises a major liability question. Also, complex computer-driven technology is used in direct patient care. Defective or improperly used hardware or software can lead to patient injury, thus raising additional complicated questions of professional liability and product liability.
Computer-Aided Facilities Management Systems (CAFM).
ERIC Educational Resources Information Center
Cyros, Kreon L.
Computer-aided facilities management (CAFM) refers to a collection of software used with increasing frequency by facilities managers. The six major CAFM components are discussed with respect to their usefulness and popularity in facilities management applications: (1) computer-aided design; (2) computer-aided engineering; (3) decision support…
Analog Computer-Aided Detection (CAD) information can be more effective than binary marks.
Cunningham, Corbin A; Drew, Trafton; Wolfe, Jeremy M
2017-02-01
In socially important visual search tasks, such as baggage screening and diagnostic radiology, experts miss more targets than is desirable. Computer-aided detection (CAD) programs have been developed specifically to improve performance in these professional search tasks. For example, in breast cancer screening, many CAD systems are capable of detecting approximately 90% of breast cancer, with approximately 0.5 false-positive detections per image. Nevertheless, benefits of CAD in clinical settings tend to be small (Birdwell, 2009) or even absent (Meziane et al., 2011; Philpotts, 2009). The marks made by a CAD system can be "binary," giving the same signal to any location where the signal is above some threshold. Alternatively, a CAD system presents an analog signal that reflects strength of the signal at a location. In the experiments reported, we compare analog and binary CAD presentations using nonexpert observers and artificial stimuli defined by two noisy signals: a visible color signal and an "invisible" signal that informed our simulated CAD system. We found that analog CAD generally yielded better overall performance than binary CAD. The analog benefit is similar at high and low target prevalence. Our data suggest that the form of the CAD signal can directly influence performance. Analog CAD may allow the computer to be more helpful to the searcher.
NASA Astrophysics Data System (ADS)
Glotsos, Dimitris; Kostopoulos, Spiros; Sidiropoulos, Konstantinos; Ravazoula, Panagiota; Kalatzis, Ioannis; Asvestas, Pantelis; Cavouras, Dionisis
2014-01-01
In this study a Computer-Aided Microscopy (CAM) system is proposed for investigating the importance of the histological criteria involved in diagnosing of cancers in microscopy in order to suggest the more informative features for discriminating low from high-grade brain tumours. Four families of criteria have been examined, involving the greylevel variations (i.e. texture), the morphology (i.e. roundness), the architecture (i.e. cellularity) and the overall tumour qualities (expert's ordinal scale). The proposed CAM system was constructed using a modified Seeded Region Growing algorithm for image segmentation, and the Probabilistic Neural Network classifier for image classification. The implementation was designed on a commercial Graphics Processing Unit card using parallel programming. The system's performance using textural, morphological, architectural and ordinal information was 90.8%, 87.0%, 81.2% and 88.9% respectively. Results indicate that nuclei texture is the most important family of features regarding the degree of malignancy, and, thus, may guide more accurate predictions for discriminating low from high grade gliomas. Considering that nuclei texture is almost impractical to be encoded by visual observation, the need to incorporate computer-aided diagnostic tools as second opinion in daily clinical practice of diagnosing rare brain tumours may be justified.
Observer training for computer-aided detection of pulmonary nodules in chest radiography.
De Boo, Diederick W; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J; Freling, Nicole J; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M
2012-08-01
To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a different order by six readers. Lesion presence, location and diagnostic confidence were scored without and with CAD (IQQA-Chest, EDDA Technology) as second reader. Readers received individual feedback after each subset. Sensitivity, specificity and area under the receiver-operating characteristics curve (AUC) were calculated for readings with and without CAD with respect to change over time and impact of CAD. CAD stand-alone sensitivity was 59 % with 1.9 false-positives per image. Mean AUC slightly increased over time with and without CAD (0.78 vs. 0.84 with and 0.76 vs. 0.82 without CAD) but differences did not reach significance. The sensitivity increased (65 % vs. 70 % and 66 % vs. 70 %) and specificity decreased over time (79 % vs. 74 % and 80 % vs. 77 %) but no significant impact of CAD was found. Short-term feedback does not increase the ability of readers to differentiate true- from false-positive candidate lesions and to use CAD more effectively. • Computer-aided detection (CAD) is increasingly used as an adjunct for many radiological techniques. • Short-term feedback does not improve reader performance with CAD in chest radiography. • Differentiation between true- and false-positive CAD for low conspicious possible lesions proves difficult. • CAD can potentially increase reader performance for nodule detection in chest radiography.
Computer-aided diagnosis in radiological imaging: current status and future challenges
NASA Astrophysics Data System (ADS)
Doi, Kunio
2009-10-01
Computer-aided diagnosis (CAD) has become one of the major research subjects in medical imaging and diagnostic radiology. Many different types of CAD schemes are being developed for detection and/or characterization of various lesions in medical imaging, including conventional projection radiography, CT, MRI, and ultrasound imaging. Commercial systems for detection of breast lesions on mammograms have been developed and have received FDA approval for clinical use. CAD may be defined as a diagnosis made by a physician who takes into account the computer output as a "second opinion". The purpose of CAD is to improve the quality and productivity of physicians in their interpretation of radiologic images. The quality of their work can be improved in terms of the accuracy and consistency of their radiologic diagnoses. In addition, the productivity of radiologists is expected to be improved by a reduction in the time required for their image readings. The computer output is derived from quantitative analysis of radiologic images by use of various methods and techniques in computer vision, artificial intelligence, and artificial neural networks (ANNs). The computer output may indicate a number of important parameters, for example, the locations of potential lesions such as lung cancer and breast cancer, the likelihood of malignancy of detected lesions, and the likelihood of various diseases based on differential diagnosis in a given image and clinical parameters. In this review article, the basic concept of CAD is first defined, and the current status of CAD research is then described. In addition, the potential of CAD in the future is discussed and predicted.
Madhavan, Poornima; Wiegmann, Douglas A
2005-01-01
Automation users often disagree with diagnostic aids that are imperfectly reliable. The extent to which users' agreements with an aid are anchored to their personal, self-generated diagnoses was explored. Participants (N = 75) performed 200 trials in which they diagnosed pump failures using an imperfectly reliable automated aid. One group (nonforced anchor, n = 50) provided diagnoses only after consulting the aid. Another group (forced anchor, n = 25) provided diagnoses both before and after receiving feedback from the aid. Within the nonforced anchor group, participants' self-reported tendency to prediagnose system failures significantly predicted their tendency to disagree with the aid, revealing a cognitive anchoring effect. Agreement rates of participants in the forced anchor group indicated that public commitment to a diagnosis did not strengthen this effect. Potential applications include the development of methods for reducing cognitive anchoring effects and improving automation utilization in high-risk domains.
ERIC Educational Resources Information Center
Hagge, John
1986-01-01
Focuses on problems encountered with computer-aided writing instruction. Discusses conflicts caused by the computer classroom concept, some general paradoxes and ethical implications of computer-aided instruction. (EL)
An open access thyroid ultrasound image database
NASA Astrophysics Data System (ADS)
Pedraza, Lina; Vargas, Carlos; Narváez, Fabián.; Durán, Oscar; Muñoz, Emma; Romero, Eduardo
2015-01-01
Computer aided diagnosis systems (CAD) have been developed to assist radiologists in the detection and diagnosis of abnormalities and a large number of pattern recognition techniques have been proposed to obtain a second opinion. Most of these strategies have been evaluated using different datasets making their performance incomparable. In this work, an open access database of thyroid ultrasound images is presented. The dataset consists of a set of B-mode Ultrasound images, including a complete annotation and diagnostic description of suspicious thyroid lesions by expert radiologists. Several types of lesions as thyroiditis, cystic nodules, adenomas and thyroid cancers were included while an accurate lesion delineation is provided in XML format. The diagnostic description of malignant lesions was confirmed by biopsy. The proposed new database is expected to be a resource for the community to assess different CAD systems.
NASA Technical Reports Server (NTRS)
Nieten, Joseph; Burke, Roger
1993-01-01
Consideration is given to the System Diagnostic Builder (SDB), an automated knowledge acquisition tool using state-of-the-art AI technologies. The SDB employs an inductive machine learning technique to generate rules from data sets that are classified by a subject matter expert. Thus, data are captured from the subject system, classified, and used to drive the rule generation process. These rule bases are used to represent the observable behavior of the subject system, and to represent knowledge about this system. The knowledge bases captured from the Shuttle Mission Simulator can be used as black box simulations by the Intelligent Computer Aided Training devices. The SDB can also be used to construct knowledge bases for the process control industry, such as chemical production or oil and gas production.
Sugimoto, Katsutoshi; Shiraishi, Junji; Moriyasu, Fuminori; Doi, Kunio
2009-04-01
To develop a computer-aided diagnostic (CAD) scheme for classifying focal liver lesions (FLLs) by use of physicians' subjective classification of echogenic patterns of FLLs on baseline and contrast-enhanced ultrasonography (US). A total of 137 hepatic lesions in 137 patients were evaluated with B-mode and NC100100 (Sonazoid)-enhanced pulse-inversion US; lesions included 74 hepatocellular carcinomas (HCCs) (23: well-differentiated, 36: moderately differentiated, 15: poorly differentiated HCCs), 33 liver metastases, and 30 liver hemangiomas. Three physicians evaluated single images at B-mode and arterial phases with a cine mode. Physicians were asked to classify each lesion into one of eight B-mode and one of eight enhancement patterns, but did not make a diagnosis. To classify five types of FLLs, we employed a decision tree model with four decision nodes and four artificial neural networks (ANNs). The results of the physicians' pattern classifications were used successively for four different ANNs in making decisions at each of the decision nodes in the decision tree model. The classification accuracies for the 137 FLLs were 84.8% for metastasis, 93.3% for hemangioma, and 98.6% for all HCCs. In addition, the classification accuracies for histological differentiation types of HCCs were 65.2% for well-differentiated HCC, 41.7% for moderately differentiated HCC, and 80.0% for poorly differentiated HCC. This CAD scheme has the potential to improve the diagnostic accuracy of liver lesions. However, the accuracy in the histologic differential diagnosis of HCC based on baseline and contrast-enhanced US is still limited.
Project-Based Teaching-Learning Computer-Aided Engineering Tools
ERIC Educational Resources Information Center
Simoes, J. A.; Relvas, C.; Moreira, R.
2004-01-01
Computer-aided design, computer-aided manufacturing, computer-aided analysis, reverse engineering and rapid prototyping are tools that play an important key role within product design. These are areas of technical knowledge that must be part of engineering and industrial design courses' curricula. This paper describes our teaching experience of…
Zhang, Z L; Li, J P; Li, G; Ma, X C
2017-02-09
Objective: To establish and validate a computer program used to aid the detection of dental proximal caries in the images cone beam computed tomography (CBCT) images. Methods: According to the characteristics of caries lesions in X-ray images, a computer aided detection program for proximal caries was established with Matlab and Visual C++. The whole process for caries lesion detection included image import and preprocessing, measuring average gray value of air area, choosing region of interest and calculating gray value, defining the caries areas. The program was used to examine 90 proximal surfaces from 45 extracted human teeth collected from Peking University School and Hospital of Stomatology. The teeth were then scanned with a CBCT scanner (Promax 3D). The proximal surfaces of the teeth were respectively detected by caries detection program and scored by human observer for the extent of lesions with 6-level-scale. With histologic examination serving as the reference standard, the caries detection program and the human observer performances were assessed with receiver operating characteristic (ROC) curves. Student t -test was used to analyze the areas under the ROC curves (AUC) for the differences between caries detection program and human observer. Spearman correlation coefficient was used to analyze the detection accuracy of caries depth. Results: For the diagnosis of proximal caries in CBCT images, the AUC values of human observers and caries detection program were 0.632 and 0.703, respectively. There was a statistically significant difference between the AUC values ( P= 0.023). The correlation between program performance and gold standard (correlation coefficient r (s)=0.525) was higher than that of observer performance and gold standard ( r (s)=0.457) and there was a statistically significant difference between the correlation coefficients ( P= 0.000). Conclusions: The program that automatically detects dental proximal caries lesions could improve the diagnostic value of CBCT images.
2001-01-01
The high-tech art of digital signal processing (DSP) was pioneered at NASA's Jet Propulsion Laboratory (JPL) in the mid-1960s for use in the Apollo Lunar Landing Program. Designed to computer enhance pictures of the Moon, this technology became the basis for the Landsat Earth resources satellites and subsequently has been incorporated into a broad range of Earthbound medical and diagnostic tools. DSP is employed in advanced body imaging techniques including Computer-Aided Tomography, also known as CT and CATScan, and Magnetic Resonance Imaging (MRI). CT images are collected by irradiating a thin slice of the body with a fan-shaped x-ray beam from a number of directions around the body's perimeter. A tomographic (slice-like) picture is reconstructed from these multiple views by a computer. MRI employs a magnetic field and radio waves, rather than x-rays, to create images. In this photograph, a patient undergoes an open MRI.
Hanus, Josef; Nosek, Tomas; Zahora, Jiri; Bezrouk, Ales; Masin, Vladimir
2013-01-01
We designed and evaluated an innovative computer-aided-learning environment based on the on-line integration of computer controlled medical diagnostic devices and a medical information system for use in the preclinical medical physics education of medical students. Our learning system simulates the actual clinical environment in a hospital or primary care unit. It uses a commercial medical information system for on-line storage and processing of clinical type data acquired during physics laboratory classes. Every student adopts two roles, the role of 'patient' and the role of 'physician'. As a 'physician' the student operates the medical devices to clinically assess 'patient' colleagues and records all results in an electronic 'patient' record. We also introduced an innovative approach to the use of supportive education materials, based on the methods of adaptive e-learning. A survey of student feedback is included and statistically evaluated. The results from the student feedback confirm the positive response of the latter to this novel implementation of medical physics and informatics in preclinical education. This approach not only significantly improves learning of medical physics and informatics skills but has the added advantage that it facilitates students' transition from preclinical to clinical subjects. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Georgia Univ., Athens. Div. of Vocational Education.
This guide describes the requirements for courses in computer-aided design and computer-aided manufacturing (CAD/CAM) that are part of engineering technology programs conducted in vocational-technical schools in Georgia. The guide is organized in five sections. The first section provides a rationale for occupations in design and in production,…
Employment Opportunities for the Handicapped in Programmable Automation.
ERIC Educational Resources Information Center
Swift, Richard; Leneway, Robert
A Computer Integrated Manufacturing System may make it possible for severely disabled people to custom design, machine, and manufacture either wood or metal parts. Programmable automation merges computer aided design, computer aided manufacturing, computer aided engineering, and computer integrated manufacturing systems with automated production…
Rodríguez-Álvarez, María Xosé; Roca-Pardiñas, Javier; Cadarso-Suárez, Carmen; Tahoces, Pablo G
2018-03-01
Prior to using a diagnostic test in a routine clinical setting, the rigorous evaluation of its diagnostic accuracy is essential. The receiver-operating characteristic curve is the measure of accuracy most widely used for continuous diagnostic tests. However, the possible impact of extra information about the patient (or even the environment) on diagnostic accuracy also needs to be assessed. In this paper, we focus on an estimator for the covariate-specific receiver-operating characteristic curve based on direct regression modelling and nonparametric smoothing techniques. This approach defines the class of generalised additive models for the receiver-operating characteristic curve. The main aim of the paper is to offer new inferential procedures for testing the effect of covariates on the conditional receiver-operating characteristic curve within the above-mentioned class. Specifically, two different bootstrap-based tests are suggested to check (a) the possible effect of continuous covariates on the receiver-operating characteristic curve and (b) the presence of factor-by-curve interaction terms. The validity of the proposed bootstrap-based procedures is supported by simulations. To facilitate the application of these new procedures in practice, an R-package, known as npROCRegression, is provided and briefly described. Finally, data derived from a computer-aided diagnostic system for the automatic detection of tumour masses in breast cancer is analysed.
Utilization of a CRT display light pen in the design of feedback control systems
NASA Technical Reports Server (NTRS)
Thompson, J. G.; Young, K. R.
1972-01-01
A hierarchical structure of the interlinked programs was developed to provide a flexible computer-aided design tool. A graphical input technique and a data structure are considered which provide the capability of entering the control system model description into the computer in block diagram form. An information storage and retrieval system was developed to keep track of the system description, and analysis and simulation results, and to provide them to the correct routines for further manipulation or display. Error analysis and diagnostic capabilities are discussed, and a technique was developed to reduce a transfer function to a set of nested integrals suitable for digital simulation. A general, automated block diagram reduction procedure was set up to prepare the system description for the analysis routines.
Gosnell, Jordan; Pietila, Todd; Samuel, Bennett P; Kurup, Harikrishnan K N; Haw, Marcus P; Vettukattil, Joseph J
2016-12-01
Three-dimensional (3D) printing is an emerging technology aiding diagnostics, education, and interventional, and surgical planning in congenital heart disease (CHD). Three-dimensional printing has been derived from computed tomography, cardiac magnetic resonance, and 3D echocardiography. However, individually the imaging modalities may not provide adequate visualization of complex CHD. The integration of the strengths of two or more imaging modalities has the potential to enhance visualization of cardiac pathomorphology. We describe the feasibility of hybrid 3D printing from two imaging modalities in a patient with congenitally corrected transposition of the great arteries (L-TGA). Hybrid 3D printing may be useful as an additional tool for cardiologists and cardiothoracic surgeons in planning interventions in children and adults with CHD.
Rethinking Skin Lesion Segmentation in a Convolutional Classifier.
Burdick, Jack; Marques, Oge; Weinthal, Janet; Furht, Borko
2017-10-18
Melanoma is a fatal form of skin cancer when left undiagnosed. Computer-aided diagnosis systems powered by convolutional neural networks (CNNs) can improve diagnostic accuracy and save lives. CNNs have been successfully used in both skin lesion segmentation and classification. For reasons heretofore unclear, previous works have found image segmentation to be, conflictingly, both detrimental and beneficial to skin lesion classification. We investigate the effect of expanding the segmentation border to include pixels surrounding the target lesion. Ostensibly, segmenting a target skin lesion will remove inessential information, non-lesion skin, and artifacts to aid in classification. Our results indicate that segmentation border enlargement produces, to a certain degree, better results across all metrics of interest when using a convolutional based classifier built using the transfer learning paradigm. Consequently, preprocessing methods which produce borders larger than the actual lesion can potentially improve classifier performance, more than both perfect segmentation, using dermatologist created ground truth masks, and no segmentation altogether.
Design and implementation of a bluetooth-based band-aid pulse rate sensor
NASA Astrophysics Data System (ADS)
Kumar, Prashanth S.; Oh, Sechang; Rai, Pratyush; Kwon, Hyeokjun; Banerjee, Nilanjan; Varadan, Vijay K.
2011-04-01
Remote patient monitoring systems capable of collecting vital patient data such as blood pressure readings, Electrocardiograph (ECG) waveforms, and heart rate can obviate the need for repeated visits to the hospital. Moreover, such systems that continuously monitor the human physiology can provide valuable data to prognosticate the onset of critical health problems. The key to such remote health diagnostics is the design of minimally intrusive, low cost sensors that do not impede a patient's quotidian life but at the same time collect reliable noise free data. To this end, in this paper, we design and implement a Bluetooth-based wireless sensor system with a disposable sensor element and a reusable wireless component that can be worn as a "band-aid". The sensor is a piezoelectric polymer film placed on the wrist in proximity to the radial artery. The band-aid sized sensor allows non-intrusive monitoring of the pulsatile flow of blood in the artery. The sensor, using the Bluetooth module, can communicate with any Bluetooth enabled computer, mobile phone, or PDA. The data collected from the patient can be remotely viewed and analyzed by a physician.
[30 years since the first AIDS cases were reported: history and the present. Part II].
Brůcková, Marie
2012-09-01
HIV taxonomy, morphology, biophysical properties, and replication cycle as well as modes of HIV transmission in humans are described. State of the art laboratory diagnosis of HIV/AIDS, core clinical diagnostic criteria for AIDS, and AIDS treatment guidelines are summarized. Global HIV/AIDS epidemic and relevant prevention activities are discussed.
Structural basis for pulmonary functional imaging.
Itoh, H; Nakatsu, M; Yoxtheimer, L M; Uematsu, H; Ohno, Y; Hatabu, H
2001-03-01
An understanding of fine normal lung morphology is important for effective pulmonary functional imaging. The lung specimens must be inflated. These include (a) unfixed, inflated lung specimen, (b) formaldehyde fixed lung specimen, (c) fixed, inflated dry lung specimen, and (d) histology specimen. Photography, magnified view, radiograph, computed tomography, and histology of these specimens are demonstrated. From a standpoint of diagnostic imaging, the main normal lung structures consist of airways (bronchi and bronchioles), alveoli, pulmonary vessels, secondary pulmonary lobules, and subpleural pulmonary lymphatic channels. This review summarizes fine radiologic normal lung morphology as an aid to effective pulmonary functional imaging.
NASA Astrophysics Data System (ADS)
Georgiou, Harris
2009-10-01
Medical Informatics and the application of modern signal processing in the assistance of the diagnostic process in medical imaging is one of the more recent and active research areas today. This thesis addresses a variety of issues related to the general problem of medical image analysis, specifically in mammography, and presents a series of algorithms and design approaches for all the intermediate levels of a modern system for computer-aided diagnosis (CAD). The diagnostic problem is analyzed with a systematic approach, first defining the imaging characteristics and features that are relevant to probable pathology in mammo-grams. Next, these features are quantified and fused into new, integrated radio-logical systems that exhibit embedded digital signal processing, in order to improve the final result and minimize the radiological dose for the patient. In a higher level, special algorithms are designed for detecting and encoding these clinically interest-ing imaging features, in order to be used as input to advanced pattern classifiers and machine learning models. Finally, these approaches are extended in multi-classifier models under the scope of Game Theory and optimum collective deci-sion, in order to produce efficient solutions for combining classifiers with minimum computational costs for advanced diagnostic systems. The material covered in this thesis is related to a total of 18 published papers, 6 in scientific journals and 12 in international conferences.
ERIC Educational Resources Information Center
Havas, George D.
This brief guide to materials in the Library of Congress (LC) on computer aided design and/or computer aided manufacturing lists reference materials and other information sources under 13 headings: (1) brief introductions; (2) LC subject headings used for such materials; (3) textbooks; (4) additional titles; (5) glossaries and handbooks; (6)…
Student Achievement in Computer Programming: Lecture vs Computer-Aided Instruction
ERIC Educational Resources Information Center
Tsai, San-Yun W.; Pohl, Norval F.
1978-01-01
This paper discusses a study of the differences in student learning achievement, as measured by four different types of common performance evaluation techniques, in a college-level computer programming course under three teaching/learning environments: lecture, computer-aided instruction, and lecture supplemented with computer-aided instruction.…
Twelve years' experience of computer-aided diagnosis in a district general hospital.
McAdam, W. A.; Brock, B. M.; Armitage, T.; Davenport, P.; Chan, M.; de Dombal, F. T.
1990-01-01
This paper describes experience in a modern district general hospital with a small desktop system for computer-aided diagnosis of acute abdominal pain, over a 12-year period involving 5512 cases. When compared with a baseline year (1973) in which unaided performance was monitored, during an initial study period (1974-76) the diagnostic accuracy of junior staff rose by between 10 and 15%. This higher performance level was then maintained for a decade (1976-86) despite changes in staff. The perforation rate among appendicitis cases fell from 27% to 12.5%, accompanied by a smaller fall in negative laparotomy rates. The saving in surgical bednights devoted to acute abdominal pain was approximately 15%, and the notional cost of resources saved during the first 6 years of operation was 120,000 pounds. Other hospitals have shown--in the short term--benefits similar to those obtained at Airedale District General Hospital. The long-term benefits of the system at Airedale reinforce the conclusions of the earlier short-term trials that a comparable system should probably be offered to all DGHs in the UK, not as an exercise in 'artificial intelligence' but as an effective continuing stimulus to good clinical practice. PMID:2185682
Image database for digital hand atlas
NASA Astrophysics Data System (ADS)
Cao, Fei; Huang, H. K.; Pietka, Ewa; Gilsanz, Vicente; Dey, Partha S.; Gertych, Arkadiusz; Pospiech-Kurkowska, Sywia
2003-05-01
Bone age assessment is a procedure frequently performed in pediatric patients to evaluate their growth disorder. A commonly used method is atlas matching by a visual comparison of a hand radiograph with a small reference set of old Greulich-Pyle atlas. We have developed a new digital hand atlas with a large set of clinically normal hand images of diverse ethnic groups. In this paper, we will present our system design and implementation of the digital atlas database to support the computer-aided atlas matching for bone age assessment. The system consists of a hand atlas image database, a computer-aided diagnostic (CAD) software module for image processing and atlas matching, and a Web user interface. Users can use a Web browser to push DICOM images, directly or indirectly from PACS, to the CAD server for a bone age assessment. Quantitative features on the examined image, which reflect the skeletal maturity, are then extracted and compared with patterns from the atlas image database to assess the bone age. The digital atlas method built on a large image database and current Internet technology provides an alternative to supplement or replace the traditional one for a quantitative, accurate and cost-effective assessment of bone age.
Computer-aided diagnosis software for vulvovaginal candidiasis detection from Pap smear images.
Momenzadeh, Mohammadreza; Vard, Alireza; Talebi, Ardeshir; Mehri Dehnavi, Alireza; Rabbani, Hossein
2018-01-01
Vulvovaginal candidiasis (VVC) is a common gynecologic infection and it occurs when there is overgrowth of the yeast called Candida. VVC diagnosis is usually done by observing a Pap smear sample under a microscope and searching for the conidium and mycelium components of Candida. This manual method is time consuming, subjective and tedious. Any diagnosis tools that detect VVC, semi- or full-automatically, can be very helpful to pathologists. This article presents a computer aided diagnosis (CAD) software to improve human diagnosis of VVC from Pap smear samples. The proposed software is designed based on phenotypic and morphology features of the Candida in Pap smear sample images. This software provide a user-friendly interface which consists of a set of image processing tools and analytical results that helps to detect Candida and determine severity of illness. The software was evaluated on 200 Pap smear sample images and obtained specificity of 91.04% and sensitivity of 92.48% to detect VVC. As a result, the use of the proposed software reduces diagnostic time and can be employed as a second objective opinion for pathologists. © 2017 Wiley Periodicals, Inc.
21 CFR 870.1425 - Programmable diagnostic computer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Programmable diagnostic computer. 870.1425 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1425 Programmable diagnostic computer. (a) Identification. A programmable diagnostic computer is a device that can be...
21 CFR 870.1425 - Programmable diagnostic computer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Programmable diagnostic computer. 870.1425 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1425 Programmable diagnostic computer. (a) Identification. A programmable diagnostic computer is a device that can be...
21 CFR 870.1425 - Programmable diagnostic computer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Programmable diagnostic computer. 870.1425 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1425 Programmable diagnostic computer. (a) Identification. A programmable diagnostic computer is a device that can be...
21 CFR 870.1425 - Programmable diagnostic computer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Programmable diagnostic computer. 870.1425 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1425 Programmable diagnostic computer. (a) Identification. A programmable diagnostic computer is a device that can be...
21 CFR 870.1425 - Programmable diagnostic computer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Programmable diagnostic computer. 870.1425 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1425 Programmable diagnostic computer. (a) Identification. A programmable diagnostic computer is a device that can be...
Burden-Teh, E; Phillips, R C; Thomas, K S; Ratib, S; Grindlay, D; Murphy, R
2017-11-06
The diagnosis of psoriasis in adults and children is made clinically, for both patient management and the selection of participants in research. Diagnostic criteria provide a structure for clinical assessment, which in turn helps standardize patient recruitment into clinical trials and case definitions in observational studies. The aim of this systematic review was to identify and critically appraise the published studies to date that had a primary research aim to develop or validate diagnostic criteria for psoriasis. A search of Ovid MEDLINE and Ovid Embase was conducted in October 2016. The primary objective was to record the sensitivity and specificity of diagnostic criteria for psoriasis. Secondary objectives included diagnostic recommendations, applicability to children and study characteristics. Diagnostic accuracy studies were critically appraised for risk of bias using the QUADAS-2 tool. Twenty-three studies met the inclusion criteria. None detailed clinical examination-based diagnostic criteria. The included criteria varied from genetic and molecular diagnostic models to skin imaging, histopathology, and questionnaire-based, computer-aided and traditional Chinese medicine criteria. High sensitivity and specificity (> 90%) were reported in many studies. However, the study authors often did not specify how the criteria would be used clinically or in research. This review identified studies with varying risk of bias, and due to each study developing separate criteria meta-analysis was not possible. Clinical examination-based diagnostic criteria are currently lacking for psoriasis. Future research could follow an international collaborative approach and employ study designs allowing high-quality diagnostic accuracy testing. Existing and newly developed criteria require validation. © 2017 British Association of Dermatologists.
Quantifying factors for the success of stratified medicine.
Trusheim, Mark R; Burgess, Breon; Hu, Sean Xinghua; Long, Theresa; Averbuch, Steven D; Flynn, Aiden A; Lieftucht, Alfons; Mazumder, Abhijit; Milloy, Judy; Shaw, Peter M; Swank, David; Wang, Jian; Berndt, Ernst R; Goodsaid, Federico; Palmer, Michael C
2011-10-31
Co-developing a drug with a diagnostic to create a stratified medicine - a therapy that is targeted to a specific patient population on the basis of a clinical characteristic such as a biomarker that predicts treatment response - presents challenges for product developers, regulators, payers and physicians. With the aim of developing a shared framework and tools for addressing these challenges, here we present an analysis using data from case studies in oncology and Alzheimer's disease, coupled with integrated computational modelling of clinical outcomes and developer economic value, to quantify the effects of decisions related to key issues such as the design of clinical trials. This illustrates how such analyses can aid the coordination of diagnostic and drug development, and the selection of optimal development and commercialization strategies. It also illustrates the impact of the interplay of these factors on the economic feasibility of stratified medicine, which has important implications for public policy makers.
Implementation of a low-cost mobile devices to support medical diagnosis.
García Sánchez, Carlos; Botella Juan, Guillermo; Ayuso Márquez, Fermín; González Rodríguez, Diego; Prieto-Matías, Manuel; Tirado Fernández, Francisco
2013-01-01
Medical imaging has become an absolutely essential diagnostic tool for clinical practices; at present, pathologies can be detected with an earliness never before known. Its use has not only been relegated to the field of radiology but also, increasingly, to computer-based imaging processes prior to surgery. Motion analysis, in particular, plays an important role in analyzing activities or behaviors of live objects in medicine. This short paper presents several low-cost hardware implementation approaches for the new generation of tablets and/or smartphones for estimating motion compensation and segmentation in medical images. These systems have been optimized for breast cancer diagnosis using magnetic resonance imaging technology with several advantages over traditional X-ray mammography, for example, obtaining patient information during a short period. This paper also addresses the challenge of offering a medical tool that runs on widespread portable devices, both on tablets and/or smartphones to aid in patient diagnostics.
Deep learning approach to bacterial colony classification.
Zieliński, Bartosz; Plichta, Anna; Misztal, Krzysztof; Spurek, Przemysław; Brzychczy-Włoch, Monika; Ochońska, Dorota
2017-01-01
In microbiology it is diagnostically useful to recognize various genera and species of bacteria. It can be achieved using computer-aided methods, which make the recognition processes more automatic and thus significantly reduce the time necessary for the classification. Moreover, in case of diagnostic uncertainty (the misleading similarity in shape or structure of bacterial cells), such methods can minimize the risk of incorrect recognition. In this article, we apply the state of the art method for texture analysis to classify genera and species of bacteria. This method uses deep Convolutional Neural Networks to obtain image descriptors, which are then encoded and classified with Support Vector Machine or Random Forest. To evaluate this approach and to make it comparable with other approaches, we provide a new dataset of images. DIBaS dataset (Digital Image of Bacterial Species) contains 660 images with 33 different genera and species of bacteria.
A review of intelligent systems for heart sound signal analysis.
Nabih-Ali, Mohammed; El-Dahshan, El-Sayed A; Yahia, Ashraf S
2017-10-01
Intelligent computer-aided diagnosis (CAD) systems can enhance the diagnostic capabilities of physicians and reduce the time required for accurate diagnosis. CAD systems could provide physicians with a suggestion about the diagnostic of heart diseases. The objective of this paper is to review the recent published preprocessing, feature extraction and classification techniques and their state of the art of phonocardiogram (PCG) signal analysis. Published literature reviewed in this paper shows the potential of machine learning techniques as a design tool in PCG CAD systems and reveals that the CAD systems for PCG signal analysis are still an open problem. Related studies are compared to their datasets, feature extraction techniques and the classifiers they used. Current achievements and limitations in developing CAD systems for PCG signal analysis using machine learning techniques are presented and discussed. In the light of this review, a number of future research directions for PCG signal analysis are provided.
Implementation of a Low-Cost Mobile Devices to Support Medical Diagnosis
García Sánchez, Carlos; Botella Juan, Guillermo; Ayuso Márquez, Fermín; González Rodríguez, Diego; Prieto-Matías, Manuel; Tirado Fernández, Francisco
2013-01-01
Medical imaging has become an absolutely essential diagnostic tool for clinical practices; at present, pathologies can be detected with an earliness never before known. Its use has not only been relegated to the field of radiology but also, increasingly, to computer-based imaging processes prior to surgery. Motion analysis, in particular, plays an important role in analyzing activities or behaviors of live objects in medicine. This short paper presents several low-cost hardware implementation approaches for the new generation of tablets and/or smartphones for estimating motion compensation and segmentation in medical images. These systems have been optimized for breast cancer diagnosis using magnetic resonance imaging technology with several advantages over traditional X-ray mammography, for example, obtaining patient information during a short period. This paper also addresses the challenge of offering a medical tool that runs on widespread portable devices, both on tablets and/or smartphones to aid in patient diagnostics. PMID:24489600
Silicon Wafer Advanced Packaging (SWAP). Multichip Module (MCM) Foundry Study. Version 2
1991-04-08
Next Layer Dielectric Spacing - Additional Metal Thickness Impact on Dielectric Uniformity/Adhiesion. The first step in .!Ie EPerimental design would be... design CAM - computer aided manufacturing CAE - computer aided engineering CALCE - computer aided life cycle engineering center CARMA - computer aided...expansion 5 j- CVD - chemical vapor deposition J . ..- j DA - design automation J , DEC - Digital Equipment Corporation --- DFT - design for testability
The application of computer-aided technologies in automotive styling design
NASA Astrophysics Data System (ADS)
Zheng, Ze-feng; Zhang, Ji; Zheng, Ying
2012-04-01
In automotive industry, outline design is its life and creative design is its soul indeed. Computer-aided technology has been widely used in the automotive industry and more and more attention has been paid. This paper chiefly introduce the application of computer-aided technologies including CAD, CAM and CAE, analyses the process of automotive structural design and describe the development tendency of computer-aided design.
RESPECT-Mil: Early Intervention & Outcomes Of PTSD & Depression In Primary Care
2011-03-21
Brief PTSD & depression screening (all visits) Pre-clinician diagnostic aid Patient education materials Psychosocial options Care Facilitator...visits) Pre-clinician diagnostic aid Patient education materials Psychosocial options Care Facilitator assisted follow-up option Aggressive... Patient education materials Psychosocial options Care Facilitator assisted follow-up option Aggressive facilitator outreach & monitoring Web-based
Gandhi, A; Kathuria, A; Gandhi, T
2011-06-01
To present the successful endodontic and periodontal management of a two rooted maxillary lateral incisor tooth with a complex radicular lingual groove and severe periodontal destruction using spiral computed tomography as a diagnostic aid. A 30-year-old male patient presented with a chief complaint of mobility and discharge of pus in an upper front tooth. Clinical examination revealed a sinus tract on the labial gingival surface and a 10-mm-deep periodontal pocket associated with maxillary left lateral incisor tooth. On the lingual side, a groove emerging from cingulum, continuing mesioapically down the lingual aspect of tooth was found. Intraoral periapical radiographs demonstrated a lateral periodontal defect around the mesial aspect and a diffuse radiolucency at the apex of maxillary left lateral incisor tooth. The sinus tract was traced with gutta-percha to the maxillary left lateral incisor that showed an accessory root surrounded by a large radiolucent area. A spiral computed tomographic scan for better understanding of the complicated root canal morphology of the tooth was performed. Based on the clinical, radiographic and spiral computed tomographic findings, a diagnosis of an endo-perio lesion in tooth 22 was made. Management consisted of conventional root canal treatment, radiculoplasty, root resection of accessory root and surgical curettage of the periodontal defect. Follow-up with radiographic examination at 3 months and 1 year was performed. At 1-year recall, the patient was asymptomatic, there was no evidence of the sinus tract and a 3-mm nonbleeding pocket was present in relation to tooth 22. Progression of hard tissue healing was observed in the periapical radiograph taken 1 year postoperatively. The key to achieving favourable results in this particular type of developmental anomaly is accurate diagnosis and treatment planning. The health of the periapical osseous tissues appears to be the provital factor for tooth retention. A favourable outcome can only be achieved with a comprehensive treatment approach that effectively manages all local factors that are contributing to the disease process. © 2011 International Endodontic Journal.
Computer-aided diagnosis of alcoholism-related EEG signals.
Acharya, U Rajendra; S, Vidya; Bhat, Shreya; Adeli, Hojjat; Adeli, Amir
2014-12-01
Alcoholism is a severe disorder that affects the functionality of neurons in the central nervous system (CNS) and alters the behavior of the affected person. Electroencephalogram (EEG) signals can be used as a diagnostic tool in the evaluation of subjects with alcoholism. The neurophysiological interpretation of EEG signals in persons with alcoholism (PWA) is based on observation and interpretation of the frequency and power in their EEGs compared to EEG signals from persons without alcoholism. This paper presents a review of the known features of EEGs obtained from PWA and proposes that the impact of alcoholism on the brain can be determined by computer-aided analysis of EEGs through extracting the minute variations in the EEG signals that can differentiate the EEGs of PWA from those of nonaffected persons. The authors advance the idea of automated computer-aided diagnosis (CAD) of alcoholism by employing the EEG signals. This is achieved through judicious combination of signal processing techniques such as wavelet, nonlinear dynamics, and chaos theory and pattern recognition and classification techniques. A CAD system is cost-effective and efficient and can be used as a decision support system by physicians in the diagnosis and treatment of alcoholism especially those who do not specialize in alcoholism or neurophysiology. It can also be of great value to rehabilitation centers to assess PWA over time and to monitor the impact of treatment aimed at minimizing or reversing the effects of the disease on the brain. A CAD system can be used to determine the extent of alcoholism-related changes in EEG signals (low, medium, high) and the effectiveness of therapeutic plans. Copyright © 2014 Elsevier Inc. All rights reserved.
Analog Computer-Aided Detection (CAD) information can be more effective than binary marks
Cunningham, Corbin A.; Drew, Trafton; Wolfe, Jeremy M.
2017-01-01
In socially important visual search tasks such as baggage screening and diagnostic radiology, experts miss more targets than is desirable. Computer Aided Detection (CAD) programs have been developed specifically to help improve performance in these professional search tasks. For example, in breast cancer screening, many CAD systems are capable of detecting approximately 90% of breast cancer, with approximately 0.5 false positive detections per image. Nevertheless, benefits of CAD in clinical settings tend to be small (Birdwell, 2009) or even absent (Meziane et al., 2011; Philpotts, 2009). The marks made by a CAD system can be “Binary”, giving the same signal to any location where the signal is above some threshold. Alternatively, a CAD system present an Analog signal that reflected strength of the signal at a location. In the experiments reported here, we compare analog and binary CAD presentations using non-expert observers and artificial stimuli defined by two noisy signals: a visible color signal and an "invisible" signal that informed our simulated CAD system. We found that analog CAD generally yielded better overall performance than binary CAD. The analog benefit is similar at high and low target prevalence. Our data suggest that the form of the CAD signal can directly influence performance. Analog CAD may allow the computer to be more helpful to the searcher. PMID:27928658
Relevance of deep learning to facilitate the diagnosis of HER2 status in breast cancer
Vandenberghe, Michel E.; Scott, Marietta L. J.; Scorer, Paul W.; Söderberg, Magnus; Balcerzak, Denis; Barker, Craig
2017-01-01
Tissue biomarker scoring by pathologists is central to defining the appropriate therapy for patients with cancer. Yet, inter-pathologist variability in the interpretation of ambiguous cases can affect diagnostic accuracy. Modern artificial intelligence methods such as deep learning have the potential to supplement pathologist expertise to ensure constant diagnostic accuracy. We developed a computational approach based on deep learning that automatically scores HER2, a biomarker that defines patient eligibility for anti-HER2 targeted therapies in breast cancer. In a cohort of 71 breast tumour resection samples, automated scoring showed a concordance of 83% with a pathologist. The twelve discordant cases were then independently reviewed, leading to a modification of diagnosis from initial pathologist assessment for eight cases. Diagnostic discordance was found to be largely caused by perceptual differences in assessing HER2 expression due to high HER2 staining heterogeneity. This study provides evidence that deep learning aided diagnosis can facilitate clinical decision making in breast cancer by identifying cases at high risk of misdiagnosis. PMID:28378829
21 CFR 870.1435 - Single-function, preprogrammed diagnostic computer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Single-function, preprogrammed diagnostic computer... Single-function, preprogrammed diagnostic computer. (a) Identification. A single-function, preprogrammed diagnostic computer is a hard-wired computer that calculates a specific physiological or blood-flow parameter...
21 CFR 870.1435 - Single-function, preprogrammed diagnostic computer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Single-function, preprogrammed diagnostic computer... Single-function, preprogrammed diagnostic computer. (a) Identification. A single-function, preprogrammed diagnostic computer is a hard-wired computer that calculates a specific physiological or blood-flow parameter...
21 CFR 870.1435 - Single-function, preprogrammed diagnostic computer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Single-function, preprogrammed diagnostic computer... Single-function, preprogrammed diagnostic computer. (a) Identification. A single-function, preprogrammed diagnostic computer is a hard-wired computer that calculates a specific physiological or blood-flow parameter...
21 CFR 870.1435 - Single-function, preprogrammed diagnostic computer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Single-function, preprogrammed diagnostic computer... Single-function, preprogrammed diagnostic computer. (a) Identification. A single-function, preprogrammed diagnostic computer is a hard-wired computer that calculates a specific physiological or blood-flow parameter...
Domain Adaptation for Alzheimer’s Disease Diagnostics
Wachinger, Christian; Reuter, Martin
2016-01-01
With the increasing prevalence of Alzheimer’s disease, research focuses on the early computer-aided diagnosis of dementia with the goal to understand the disease process, determine risk and preserving factors, and explore preventive therapies. By now, large amounts of data from multi-site studies have been made available for developing, training, and evaluating automated classifiers. Yet, their translation to the clinic remains challenging, in part due to their limited generalizability across different datasets. In this work, we describe a compact classification approach that mitigates overfitting by regularizing the multinomial regression with the mixed ℓ1/ℓ2 norm. We combine volume, thickness, and anatomical shape features from MRI scans to characterize neuroanatomy for the three-class classification of Alzheimer’s disease, mild cognitive impairment and healthy controls. We demonstrate high classification accuracy via independent evaluation within the scope of the CADDementia challenge. We, furthermore, demonstrate that variations between source and target datasets can substantially influence classification accuracy. The main contribution of this work addresses this problem by proposing an approach for supervised domain adaptation based on instance weighting. Integration of this method into our classifier allows us to assess different strategies for domain adaptation. Our results demonstrate (i) that training on only the target training set yields better results than the naïve combination (union) of source and target training sets, and (ii) that domain adaptation with instance weighting yields the best classification results, especially if only a small training component of the target dataset is available. These insights imply that successful deployment of systems for computer-aided diagnostics to the clinic depends not only on accurate classifiers that avoid overfitting, but also on a dedicated domain adaptation strategy. PMID:27262241
Computer-aided diagnostics of screening mammography using content-based image retrieval
NASA Astrophysics Data System (ADS)
Deserno, Thomas M.; Soiron, Michael; de Oliveira, Júlia E. E.; de A. Araújo, Arnaldo
2012-03-01
Breast cancer is one of the main causes of death among women in occidental countries. In the last years, screening mammography has been established worldwide for early detection of breast cancer, and computer-aided diagnostics (CAD) is being developed to assist physicians reading mammograms. A promising method for CAD is content-based image retrieval (CBIR). Recently, we have developed a classification scheme of suspicious tissue pattern based on the support vector machine (SVM). In this paper, we continue moving towards automatic CAD of screening mammography. The experiments are based on in total 10,509 radiographs that have been collected from different sources. From this, 3,375 images are provided with one and 430 radiographs with more than one chain code annotation of cancerous regions. In different experiments, this data is divided into 12 and 20 classes, distinguishing between four categories of tissue density, three categories of pathology and in the 20 class problem two categories of different types of lesions. Balancing the number of images in each class yields 233 and 45 images remaining in each of the 12 and 20 classes, respectively. Using a two-dimensional principal component analysis, features are extracted from small patches of 128 x 128 pixels and classified by means of a SVM. Overall, the accuracy of the raw classification was 61.6 % and 52.1 % for the 12 and the 20 class problem, respectively. The confusion matrices are assessed for detailed analysis. Furthermore, an implementation of a SVM-based CBIR system for CADx in screening mammography is presented. In conclusion, with a smarter patch extraction, the CBIR approach might reach precision rates that are helpful for the physicians. This, however, needs more comprehensive evaluation on clinical data.
Enhancing an appointment diary on a pocket computer for use by people after brain injury.
Wright, P; Rogers, N; Hall, C; Wilson, B; Evans, J; Emslie, H
2001-12-01
People with memory loss resulting from brain injury benefit from purpose-designed memory aids such as appointment diaries on pocket computers. The present study explores the effects of extending the range of memory aids and including games. For 2 months, 12 people who had sustained brain injury were loaned a pocket computer containing three purpose-designed memory aids: diary, notebook and to-do list. A month later they were given another computer with the same memory aids but a different method of text entry (physical keyboard or touch-screen keyboard). Machine order was counterbalanced across participants. Assessment was by interviews during the loan periods, rating scales, performance tests and computer log files. All participants could use the memory aids and ten people (83%) found them very useful. Correlations among the three memory aids were not significant, suggesting individual variation in how they were used. Games did not increase use of the memory aids, nor did loan of the preferred pocket computer (with physical keyboard). Significantly more diary entries were made by people who had previously used other memory aids, suggesting that a better understanding of how to use a range of memory aids could benefit some people with brain injury.
Computer-aided biochemical programming of synthetic microreactors as diagnostic devices.
Courbet, Alexis; Amar, Patrick; Fages, François; Renard, Eric; Molina, Franck
2018-04-26
Biological systems have evolved efficient sensing and decision-making mechanisms to maximize fitness in changing molecular environments. Synthetic biologists have exploited these capabilities to engineer control on information and energy processing in living cells. While engineered organisms pose important technological and ethical challenges, de novo assembly of non-living biomolecular devices could offer promising avenues toward various real-world applications. However, assembling biochemical parts into functional information processing systems has remained challenging due to extensive multidimensional parameter spaces that must be sampled comprehensively in order to identify robust, specification compliant molecular implementations. We introduce a systematic methodology based on automated computational design and microfluidics enabling the programming of synthetic cell-like microreactors embedding biochemical logic circuits, or protosensors , to perform accurate biosensing and biocomputing operations in vitro according to temporal logic specifications. We show that proof-of-concept protosensors integrating diagnostic algorithms detect specific patterns of biomarkers in human clinical samples. Protosensors may enable novel approaches to medicine and represent a step toward autonomous micromachines capable of precise interfacing of human physiology or other complex biological environments, ecosystems, or industrial bioprocesses. © 2018 The Authors. Published under the terms of the CC BY 4.0 license.
Computer-aided design and computer science technology
NASA Technical Reports Server (NTRS)
Fulton, R. E.; Voigt, S. J.
1976-01-01
A description is presented of computer-aided design requirements and the resulting computer science advances needed to support aerospace design. The aerospace design environment is examined, taking into account problems of data handling and aspects of computer hardware and software. The interactive terminal is normally the primary interface between the computer system and the engineering designer. Attention is given to user aids, interactive design, interactive computations, the characteristics of design information, data management requirements, hardware advancements, and computer science developments.
Hearing Aid Fitting in Infants.
ERIC Educational Resources Information Center
Hoover, Brenda M.
2000-01-01
This article examines the latest technological advances in hearing aids and explores the available research to help families and professionals make informed decisions when fitting amplification devices on infants and young children. Diagnostic procedures, evaluation techniques, hearing aid selection, circuit and advanced technology options, and…
Computer Instructional Aids for Undergraduate Control Education.
ERIC Educational Resources Information Center
Volz, Richard A.; And Others
Engineering is coming to rely more and more heavily upon the computer for computations, analyses, and graphic displays which aid the design process. A general purpose simulation system, the Time-shared Automatic Control Laboratory (TACL), and a set of computer-aided design programs, Control Oriented Interactive Graphic Analysis and Design…
Disseminated histoplasmosis and AIDS: clinical aspects and diagnostic methods for early detection.
Corti, M E; Cendoya, C A; Soto, I; Esquivel, P; Trione, N; Villafañe, M F; Corbera, K M; Helou, S; Negroni, R
2000-03-01
Disseminated histoplasmosis in AIDS patients is the focus of this paper. Cutaneous lesions are reported as a frequent clinical sign. Bone marrow aspiration and biopsy, blood cultures (lysis-centrifugation technique), bronchoalveolar lavage, and skin lesion scrapings are the most effective diagnostic methods. The identification of a specific antigen in blood and urine may be a rapid means of evaluation and follow-up of patients with this disease.
Digital hand atlas and computer-aided bone age assessment via the Web
NASA Astrophysics Data System (ADS)
Cao, Fei; Huang, H. K.; Pietka, Ewa; Gilsanz, Vicente
1999-07-01
A frequently used assessment method of bone age is atlas matching by a radiological examination of a hand image against a reference set of atlas patterns of normal standards. We are in a process of developing a digital hand atlas with a large standard set of normal hand and wrist images that reflect the skeletal maturity, race and sex difference, and current child development. The digital hand atlas will be used for a computer-aided bone age assessment via Web. We have designed and partially implemented a computer-aided diagnostic (CAD) system for Web-based bone age assessment. The system consists of a digital hand atlas, a relational image database and a Web-based user interface. The digital atlas is based on a large standard set of normal hand an wrist images with extracted bone objects and quantitative features. The image database uses a content- based indexing to organize the hand images and their attributes and present to users in a structured way. The Web-based user interface allows users to interact with the hand image database from browsers. Users can use a Web browser to push a clinical hand image to the CAD server for a bone age assessment. Quantitative features on the examined image, which reflect the skeletal maturity, will be extracted and compared with patterns from the atlas database to assess the bone age. The relevant reference imags and the final assessment report will be sent back to the user's browser via Web. The digital atlas will remove the disadvantages of the currently out-of-date one and allow the bone age assessment to be computerized and done conveniently via Web. In this paper, we present the system design and Web-based client-server model for computer-assisted bone age assessment and our initial implementation of the digital atlas database.
1986-07-01
COMPUTER-AIDED OPERATION MANAGEMENT SYSTEM ................. 29 Functions of an Off-Line Computer-Aided Operation Management System Applications of...System Comparisons 85 DISTRIBUTION 5V J. • 0. FIGURES Number Page 1 Hardware Components 21 2 Basic Functions of a Computer-Aided Operation Management System...Plant Visits 26 4 Computer-Aided Operation Management Systems Reviewed for Analysis of Basic Functions 29 5 Progress of Software System Installation and
Care 3 phase 2 report, maintenance manual
NASA Technical Reports Server (NTRS)
Bryant, L. A.; Stiffler, J. J.
1982-01-01
CARE 3 (Computer-Aided Reliability Estimation, version three) is a computer program designed to help estimate the reliability of complex, redundant systems. Although the program can model a wide variety of redundant structures, it was developed specifically for fault-tolerant avionics systems--systems distinguished by the need for extremely reliable performance since a system failure could well result in the loss of human life. It substantially generalizes the class of redundant configurations that could be accommodated, and includes a coverage model to determine the various coverage probabilities as a function of the applicable fault recovery mechanisms (detection delay, diagnostic scheduling interval, isolation and recovery delay, etc.). CARE 3 further generalizes the class of system structures that can be modeled and greatly expands the coverage model to take into account such effects as intermittent and transient faults, latent faults, error propagation, etc.
Regional Lung Ventilation Analysis Using Temporally Resolved Magnetic Resonance Imaging.
Kolb, Christoph; Wetscherek, Andreas; Buzan, Maria Teodora; Werner, René; Rank, Christopher M; Kachelrie, Marc; Kreuter, Michael; Dinkel, Julien; Heuel, Claus Peter; Maier-Hein, Klaus
We propose a computer-aided method for regional ventilation analysis and observation of lung diseases in temporally resolved magnetic resonance imaging (4D MRI). A shape model-based segmentation and registration workflow was used to create an atlas-derived reference system in which regional tissue motion can be quantified and multimodal image data can be compared regionally. Model-based temporal registration of the lung surfaces in 4D MRI data was compared with the registration of 4D computed tomography (CT) images. A ventilation analysis was performed on 4D MR images of patients with lung fibrosis; 4D MR ventilation maps were compared with corresponding diagnostic 3D CT images of the patients and 4D CT maps of subjects without impaired lung function (serving as reference). Comparison between the computed patient-specific 4D MR regional ventilation maps and diagnostic CT images shows good correlation in conspicuous regions. Comparison to 4D CT-derived ventilation maps supports the plausibility of the 4D MR maps. Dynamic MRI-based flow-volume loops and spirograms further visualize the free-breathing behavior. The proposed methods allow for 4D MR-based regional analysis of tissue dynamics and ventilation in spontaneous breathing and comparison of patient data. The proposed atlas-based reference coordinate system provides an automated manner of annotating and comparing multimodal lung image data.
ERIC Educational Resources Information Center
Cheng, Wan-Lee
This instructional manual contains 12 learning activity packets for use in a workshop in computer-aided design and drafting (CADD). The lessons cover the following topics: introduction to computer graphics and computer-aided design/drafting; coordinate systems; advance space graphics hardware configuration and basic features of the IBM PC…
RASCAL: A Rudimentary Adaptive System for Computer-Aided Learning.
ERIC Educational Resources Information Center
Stewart, John Christopher
Both the background of computer-assisted instruction (CAI) systems in general and the requirements of a computer-aided learning system which would be a reasonable assistant to a teacher are discussed. RASCAL (Rudimentary Adaptive System for Computer-Aided Learning) is a first attempt at defining a CAI system which would individualize the learning…
An ICA-based method for the segmentation of pigmented skin lesions in macroscopic images.
Cavalcanti, Pablo G; Scharcanski, Jacob; Di Persia, Leandro E; Milone, Diego H
2011-01-01
Segmentation is an important step in computer-aided diagnostic systems for pigmented skin lesions, since that a good definition of the lesion area and its boundary at the image is very important to distinguish benign from malignant cases. In this paper a new skin lesion segmentation method is proposed. This method uses Independent Component Analysis to locate skin lesions in the image, and this location information is further refined by a Level-set segmentation method. Our method was evaluated in 141 images and achieved an average segmentation error of 16.55%, lower than the results for comparable state-of-the-art methods proposed in literature.
NASA Astrophysics Data System (ADS)
Seong, Won; Cho, June-Sik; Noh, Seung-Moo; Park, Jong-Won
In general, the spleen accompanied by abnormal abdomen is hypertrophied. However, if the spleen size is originally small, it is hard to detect the splenic enlargement due to abnormal abdomen by simply measure the size. On the contrary, the spleen size of a person having a normal abdomen may be large by nature. Therefore, measuring the size of spleen is not a reliable diagnostic measure of its enlargement or the abdomen abnormality. This paper proposes an automatic method to diagnose the splenic enlargement due to abnormality, by examining the boundary pattern of spleen in abdominal CT images.
Computer-Aided Drug Discovery: Molecular Docking of Diminazene Ligands to DNA Minor Groove
ERIC Educational Resources Information Center
Kholod, Yana; Hoag, Erin; Muratore, Katlynn; Kosenkov, Dmytro
2018-01-01
The reported project-based laboratory unit introduces upper-division undergraduate students to the basics of computer-aided drug discovery as a part of a computational chemistry laboratory course. The students learn to perform model binding of organic molecules (ligands) to the DNA minor groove with computer-aided drug discovery (CADD) tools. The…
Jiang, Yulei; Inciardi, Marc F; Edwards, Alexandra V; Papaioannou, John
2018-05-24
The purpose of this study was to compare diagnostic accuracy and interpretation time of screening automated breast ultrasound (ABUS) for women with dense breast tissue without and with use of a recently U.S. Food and Drug Administration-approved computer-aided detection (CAD) system for concurrent read. In a retrospective observer performance study, 18 radiologists interpreted a cancer-enriched set (i.e., cancer prevalence higher than in the original screening cohort) of 185 screening ABUS studies (52 with and 133 without breast cancer). These studies were from a large cohort of ABUS screened patients interpreted as BI-RADS density C or D. Each reader interpreted each case twice in a counterbalanced study, once without the CAD system and once with it, separated by 4 weeks. For each case, each reader identified abnormal findings and reported BI-RADS assessment category and level of suspicion for breast cancer. Interpretation time was recorded. Level of suspicion data were compared to evaluate diagnostic accuracy by means of the Dorfman-Berbaum-Metz method of jackknife with ANOVA ROC analysis. Interpretation times were compared by ANOVA. The ROC AUC was 0.848 with the CAD system, compared with 0.828 without it, for a difference of 0.020 (95% CI, -0.011 to 0.051) and was statistically noninferior to the AUC without the CAD system with respect to a margin of -0.05 (p = 0.000086). The mean interpretation time was 3 minutes 33 seconds per case without the CAD system and 2 minutes 24 seconds with it, for a difference of 1 minute 9 seconds saved (95% CI, 44-93 seconds; p = 0.000014), or a reduction in interpretation time to 67% of the time without the CAD system. Use of the concurrent-read CAD system for interpretation of screening ABUS studies of women with dense breast tissue who do not have symptoms is expected to make interpretation significantly faster and produce noninferior diagnostic accuracy compared with interpretation without the CAD system.
NASA Astrophysics Data System (ADS)
Alshipli, Marwan; Kabir, Norlaili A.
2017-05-01
Computed tomography (CT) employs X-ray radiation to create cross-sectional images. Dual-energy CT acquisition includes the images acquired from an alternating voltage of X-ray tube: a low- and a high-peak kilovoltage. The main objective of this study is to determine the best slice thickness that reduces image noise with adequate diagnostic information using dual energy CT head protocol. The study used the ImageJ software and statistical analyses to aid the medical image analysis of dual-energy CT. In this study, ImageJ software and F-test were utilised as the combination methods to analyse DICOM CT images. They were used to investigate the effect of slice thickness on noise and visibility in dual-energy CT head protocol images. Catphan-600 phantom was scanned at different slice thickness values;.6, 1, 2, 3, 4, 5 and 6 mm, then quantitative analyses were carried out. The DECT operated in helical mode with another fixed scan parameter values. Based on F-test statistical analyses, image noise at 0.6, 1, and 2 mm were significantly different compared to the other images acquired at slice thickness of 3, 4, 5, and 6 mm. However, no significant differences of image noise were observed at 3, 4, 5, and 6 mm. As a result, better diagnostic image value, image visibility, and lower image noise in dual-energy CT head protocol was observed at a slice thickness of 3 mm.
Hoo, Zhe Hui; Candlish, Jane; Teare, Dawn
2017-06-01
The paper by Body et al is concerned with the evaluation of decision aids, which can be used to identify potential acute coronary syndromes (ACS) in the ED. The authors previously developed the Manchester Acute Coronary Syndromes model (MACS) decision aid, which uses several clinical variables and two biomarkers to 'rule in' and 'rule out' ACS. However, one of the two biomarkers (heart-type fatty acid bindingprotein, H-FABP) is not widely used so a revised decision aid has been developed (Troponin-only Manchester Acute Coronary Syndromes, T-MACS), which include a single biomarker hs-cTnT. In this issue, the authors show how they derive a revised decision aid and describe its performance in a number of independent diagnostic cohort studies. Decision aids (as well as other types of 'diagnostic tests') are often evaluated in terms of diagnostic testing parameters such as the area under the receiver operating characteristic (ROC) curve, sensitivity and specificity. In this article, we explain how the ROC analysis is conducted and why it is an essential step towards developing a test with the desirable levels of sensitivity and specificity. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
The role of modern diagnostic imaging in diagnosing and differentiating kidney diseases in children.
Maliborski, Artur; Zegadło, Arkadiusz; Placzyńska, Małgorzata; Sopińska, Małgorzata; Lichosik, Marianna; Jobs, Katarzyna
2018-01-01
Urinary tract diseases are in the group of the most commonly diagnosed medical conditions in pediatric patients. Many diseases with different etiologies are accompanied by pain, fever, hematuria, or urinary tract dysfunction. Those most common ones in children are urinary tract infections and congenital malformation. They can also represent tumors or changes caused by systemic diseases. Clinical tests and even more often additional imaging studies are required to make a proper diagnosis of urinary tract diseases. Just a few decades ago urography, cystography or voiding cystourethrography were the main methods in diagnostic imaging of the urinary tract. Today's imaging methods supported by digital radiographic and fluoroscopy systems, high sensitivity detectors with quantum detection, advanced algorithms eliminating motion artifacts, modern medical imaging monitors with a resolution of three or even eight megapixels significantly differ from conventional radiographic methods. The methods that are currently usually performed are: computed tomography, magnetic resonance imaging, isotopic methods and ultrasonography using elastography and new solutions in Doppler imaging. Modern techniques are currently focused on reducing radiation exposure with better imaging capabilities. The development of these techniques became an essential diagnostic aid in nephrological and urological practice. The aim of this paper is to present the latest solutions that are currently used in the diagnostic imaging of urinary tract diseases.
NASA Astrophysics Data System (ADS)
Aghaei, Faranak; Mirniaharikandehei, Seyedehnafiseh; Hollingsworth, Alan B.; Stoug, Rebecca G.; Pearce, Melanie; Liu, Hong; Zheng, Bin
2018-03-01
Although breast magnetic resonance imaging (MRI) has been used as a breast cancer screening modality for high-risk women, its cancer detection yield remains low (i.e., <= 3%). Thus, increasing breast MRI screening efficacy and cancer detection yield is an important clinical issue in breast cancer screening. In this study, we investigated association between the background parenchymal enhancement (BPE) of breast MRI and the change of diagnostic (BIRADS) status in the next subsequent breast MRI screening. A dataset with 65 breast MRI screening cases was retrospectively assembled. All cases were rated BIRADS-2 (benign findings). In the subsequent screening, 4 cases were malignant (BIRADS-6), 48 remained BIRADS-2 and 13 were downgraded to negative (BIRADS-1). A computer-aided detection scheme was applied to process images of the first set of breast MRI screening. Total of 33 features were computed including texture feature and global BPE features. Texture features were computed from either a gray-level co-occurrence matrix or a gray level run length matrix. Ten global BPE features were also initially computed from two breast regions and bilateral difference between the left and right breasts. Box-plot based analysis shows positive association between texture features and BIRADS rating levels in the second screening. Furthermore, a logistic regression model was built using optimal features selected by a CFS based feature selection method. Using a leave-one-case-out based cross-validation method, classification yielded an overall 75% accuracy in predicting the improvement (or downgrade) of diagnostic status (to BIRAD-1) in the subsequent breast MRI screening. This study demonstrated potential of developing a new quantitative imaging marker to predict diagnostic status change in the short-term, which may help eliminate a high fraction of unnecessary repeated breast MRI screenings and increase the cancer detection yield.
NASA Technical Reports Server (NTRS)
Kolb, Mark A.
1990-01-01
Viewgraphs on Rubber Airplane: Constraint-based Component-Modeling for Knowledge Representation in Computer Aided Conceptual Design are presented. Topics covered include: computer aided design; object oriented programming; airfoil design; surveillance aircraft; commercial aircraft; aircraft design; and launch vehicles.
Wei, Xuelei; Dong, Fuhui
2011-12-01
To review recent advance in the research and application of computer aided forming techniques for constructing bone tissue engineering scaffolds. The literature concerning computer aided forming techniques for constructing bone tissue engineering scaffolds in recent years was reviewed extensively and summarized. Several studies over last decade have focused on computer aided forming techniques for bone scaffold construction using various scaffold materials, which is based on computer aided design (CAD) and bone scaffold rapid prototyping (RP). CAD include medical CAD, STL, and reverse design. Reverse design can fully simulate normal bone tissue and could be very useful for the CAD. RP techniques include fused deposition modeling, three dimensional printing, selected laser sintering, three dimensional bioplotting, and low-temperature deposition manufacturing. These techniques provide a new way to construct bone tissue engineering scaffolds with complex internal structures. With rapid development of molding and forming techniques, computer aided forming techniques are expected to provide ideal bone tissue engineering scaffolds.
The Impact of Machine Translation and Computer-aided Translation on Translators
NASA Astrophysics Data System (ADS)
Peng, Hao
2018-03-01
Under the context of globalization, communications between countries and cultures are becoming increasingly frequent, which make it imperative to use some techniques to help translate. This paper is to explore the influence of computer-aided translation on translators, which is derived from the field of the computer-aided translation (CAT) and machine translation (MT). Followed by an introduction to the development of machine and computer-aided translation, it then depicts the technologies practicable to translators, which are trying to analyze the demand of designing the computer-aided translation so far in translation practice, and optimize the designation of computer-aided translation techniques, and analyze its operability in translation. The findings underline the advantages and disadvantages of MT and CAT tools, and the serviceability and future development of MT and CAT technologies. Finally, this thesis probes into the impact of these new technologies on translators in hope that more translators and translation researchers can learn to use such tools to improve their productivity.
Ethical Implications: Screening for and Treatment of AIDS.
ERIC Educational Resources Information Center
Chng, Chwee Lye; Roddy, William Meyer
1987-01-01
This article discusses the ethical implications of using tests intended only to protect the blood supply as diagnostic or prognostic tests for Acquired Immune Deficiency Syndrome (AIDS). The reliability of these tests and the confidentiality of their results are discussed, along with ethical issues of research regarding AIDS. (MT)
NASA Astrophysics Data System (ADS)
Smith, B.
2015-12-01
In 2014, eight Department of Energy (DOE) national laboratories, four academic institutions, one company, and the National Centre for Atmospheric Research combined forces in a project called Accelerated Climate Modeling for Energy (ACME) with the goal to speed Earth system model development for climate and energy. Over the planned 10-year span, the project will conduct simulations and modeling on DOE's most powerful high-performance computing systems at Oak Ridge, Argonne, and Lawrence Berkeley Leadership Compute Facilities. A key component of the ACME project is the development of an interactive test bed for the advanced Earth system model. Its execution infrastructure will accelerate model development and testing cycles. The ACME Workflow Group is leading the efforts to automate labor-intensive tasks, provide intelligent support for complex tasks and reduce duplication of effort through collaboration support. As part of this new workflow environment, we have created a diagnostic, metric, and intercomparison Python framework, called UVCMetrics, to aid in the testing-to-production execution of the ACME model. The framework exploits similarities among different diagnostics to compactly support diagnosis of new models. It presently focuses on atmosphere and land but is designed to support ocean and sea ice model components as well. This framework is built on top of the existing open-source software framework known as the Ultrascale Visualization Climate Data Analysis Tools (UV-CDAT). Because of its flexible framework design, scientists and modelers now can generate thousands of possible diagnostic outputs. These diagnostics can compare model runs, compare model vs. observation, or simply verify a model is physically realistic. Additional diagnostics are easily integrated into the framework, and our users have already added several. Diagnostics can be generated, viewed, and manipulated from the UV-CDAT graphical user interface, Python command line scripts and programs, and web browsers. The framework is designed to be scalable to large datasets, yet easy to use and familiar to scientists using previous tools. Integration in the ACME overall user interface facilitates data publication, further analysis, and quick feedback to model developers and scientists making component or coupled model runs.
Randall, David; Joosten, Frank; ten Broek, Richard; Gillott, Richard; Bardhan, Karna Dev; Strik, Chema; Prins, Wiesje; van Goor, Harry; Fenner, John
2017-07-14
A non-invasive diagnostic technique for abdominal adhesions is not currently available. Capture of abdominal motion due to respiration in cine-MRI has shown promise, but is difficult to interpret. This article explores the value of a complimentary diagnostic aid to facilitate the non-invasive detection of abdominal adhesions using cine-MRI. An image processing technique was developed to quantify the amount of sliding that occurs between the organs of the abdomen and the abdominal wall in sagittal cine-MRI slices. The technique produces a 'sheargram' which depicts the amount of sliding which has occurred over 1-3 respiratory cycles. A retrospective cohort of 52 patients, scanned for suspected adhesions, made 281 cine-MRI sagittal slices available for processing. The resulting sheargrams were reported by two operators and compared to expert clinical judgement of the cine-MRI scans. The sheargram matched clinical judgement in 84% of all sagittal slices and 93-96% of positive adhesions were identified on the sheargram. The sheargram displayed a slight skew towards sensitivity over specificity, with a high positive adhesion detection rate but at the expense of false positives. Good correlation between sheargram and absence/presence of inferred adhesions indicates quantification of sliding motion has potential to aid adhesion detection in cine-MRI. Advances in Knowledge: This is the first attempt to clinically evaluate a novel image processing technique quantifying the sliding motion of the abdominal contents against the abdominal wall. The results of this pilot study reveal its potential as a diagnostic aid for detection of abdominal adhesions.
Attributes Affecting Computer-Aided Decision Making--A Literature Survey.
ERIC Educational Resources Information Center
Moldafsky, Neil I; Kwon, Ik-Whan
1994-01-01
Reviews current literature about personal, demographic, situational, and cognitive attributes that affect computer-aided decision making. The effectiveness of computer-aided decision making is explored in relation to decision quality, effectiveness, and confidence. Studies of the effects of age, anxiety, cognitive type, attitude, gender, and prior…
User-Centered Computer Aided Language Learning
ERIC Educational Resources Information Center
Zaphiris, Panayiotis, Ed.; Zacharia, Giorgos, Ed.
2006-01-01
In the field of computer aided language learning (CALL), there is a need for emphasizing the importance of the user. "User-Centered Computer Aided Language Learning" presents methodologies, strategies, and design approaches for building interfaces for a user-centered CALL environment, creating a deeper understanding of the opportunities and…
Hearing Impairments. Tech Use Guide: Using Computer Technology.
ERIC Educational Resources Information Center
Council for Exceptional Children, Reston, VA. Center for Special Education Technology.
One of nine brief guides for special educators on using computer technology, this guide focuses on advances in electronic aids, computers, telecommunications, and videodiscs to assist students with hearing impairments. Electronic aids include hearing aids, telephone devices for the deaf, teletypes, closed captioning systems for television, and…
Computer Aided Design in Engineering Education.
ERIC Educational Resources Information Center
Gobin, R.
1986-01-01
Discusses the use of Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) systems in an undergraduate engineering education program. Provides a rationale for CAD/CAM use in the already existing engineering program. Describes the methods used in choosing the systems, some initial results, and warnings for first-time users. (TW)
Yoon, Hyung-In; Han, Jung-Suk
2016-02-01
The fabrication of dental prostheses with computer-aided design and computer-aided manufacturing shows acceptable marginal fits and favorable treatment outcomes. This clinical report describes the management of a patient who had undergone a mandibulectomy and received an implant-supported fixed prosthesis by using additive manufacturing for the framework and subtractive manufacturing for the monolithic zirconia restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Rice, Stephen; McCarley, Jason S.
2011-01-01
Automated diagnostic aids prone to false alarms often produce poorer human performance in signal detection tasks than equally reliable miss-prone aids. However, it is not yet clear whether this is attributable to differences in the perceptual salience of the automated aids' misses and false alarms or is the result of inherent differences in…
Miyazaki, Yoshiaki; Tabata, Nobuyuki; Taroura, Tomomi; Shinozaki, Kenji; Kubo, Yuichiro; Tokunaga, Eriko; Taguchi, Kenichi
We propose a computer-aided diagnostic (CAD) system that uses time-intensity curves to distinguish between benign and malignant mammary tumors. Many malignant tumors show a washout pattern in time-intensity curves. Therefore, we designed a program that automatically detects the position with the strongest washout effect using the technique, such as the subtraction technique, which extracts only the washout area in the tumor, and by scanning data in 2×2 pixel region of interest (ROI). Operation of this independently developed program was verified using a phantom system that simulated tumors. In three cases of malignant tumors, the washout pattern detection rate in images with manually set ROI was ≤6%, whereas the detection rate with our novel method was 100%. In one case of a benign tumor, when the same method was used, we checked that there was no washout effect and detected the persistent pattern. Thus, the distinction between benign and malignant tumors using our method was completely consistent with the pathological diagnoses made. Our novel method is therefore effective for differentiating between benign and malignant mammary tumors in dynamic magnetic resonance images.
Ghane, Narjes; Vard, Alireza; Talebi, Ardeshir; Nematollahy, Pardis
2017-01-01
Recognition of white blood cells (WBCs) is the first step to diagnose some particular diseases such as acquired immune deficiency syndrome, leukemia, and other blood-related diseases that are usually done by pathologists using an optical microscope. This process is time-consuming, extremely tedious, and expensive and needs experienced experts in this field. Thus, a computer-aided diagnosis system that assists pathologists in the diagnostic process can be so effective. Segmentation of WBCs is usually a first step in developing a computer-aided diagnosis system. The main purpose of this paper is to segment WBCs from microscopic images. For this purpose, we present a novel combination of thresholding, k-means clustering, and modified watershed algorithms in three stages including (1) segmentation of WBCs from a microscopic image, (2) extraction of nuclei from cell's image, and (3) separation of overlapping cells and nuclei. The evaluation results of the proposed method show that similarity measures, precision, and sensitivity respectively were 92.07, 96.07, and 94.30% for nucleus segmentation and 92.93, 97.41, and 93.78% for cell segmentation. In addition, statistical analysis presents high similarity between manual segmentation and the results obtained by the proposed method.
ICADx: interpretable computer aided diagnosis of breast masses
NASA Astrophysics Data System (ADS)
Kim, Seong Tae; Lee, Hakmin; Kim, Hak Gu; Ro, Yong Man
2018-02-01
In this study, a novel computer aided diagnosis (CADx) framework is devised to investigate interpretability for classifying breast masses. Recently, a deep learning technology has been successfully applied to medical image analysis including CADx. Existing deep learning based CADx approaches, however, have a limitation in explaining the diagnostic decision. In real clinical practice, clinical decisions could be made with reasonable explanation. So current deep learning approaches in CADx are limited in real world deployment. In this paper, we investigate interpretability in CADx with the proposed interpretable CADx (ICADx) framework. The proposed framework is devised with a generative adversarial network, which consists of interpretable diagnosis network and synthetic lesion generative network to learn the relationship between malignancy and a standardized description (BI-RADS). The lesion generative network and the interpretable diagnosis network compete in an adversarial learning so that the two networks are improved. The effectiveness of the proposed method was validated on public mammogram database. Experimental results showed that the proposed ICADx framework could provide the interpretability of mass as well as mass classification. It was mainly attributed to the fact that the proposed method was effectively trained to find the relationship between malignancy and interpretations via the adversarial learning. These results imply that the proposed ICADx framework could be a promising approach to develop the CADx system.
Computer-aided interpretation approach for optical tomographic images
NASA Astrophysics Data System (ADS)
Klose, Christian D.; Klose, Alexander D.; Netz, Uwe J.; Scheel, Alexander K.; Beuthan, Jürgen; Hielscher, Andreas H.
2010-11-01
A computer-aided interpretation approach is proposed to detect rheumatic arthritis (RA) in human finger joints using optical tomographic images. The image interpretation method employs a classification algorithm that makes use of a so-called self-organizing mapping scheme to classify fingers as either affected or unaffected by RA. Unlike in previous studies, this allows for combining multiple image features, such as minimum and maximum values of the absorption coefficient for identifying affected and not affected joints. Classification performances obtained by the proposed method were evaluated in terms of sensitivity, specificity, Youden index, and mutual information. Different methods (i.e., clinical diagnostics, ultrasound imaging, magnet resonance imaging, and inspection of optical tomographic images), were used to produce ground truth benchmarks to determine the performance of image interpretations. Using data from 100 finger joints, findings suggest that some parameter combinations lead to higher sensitivities, while others to higher specificities when compared to single parameter classifications employed in previous studies. Maximum performances are reached when combining the minimum/maximum ratio of the absorption coefficient and image variance. In this case, sensitivities and specificities over 0.9 can be achieved. These values are much higher than values obtained when only single parameter classifications were used, where sensitivities and specificities remained well below 0.8.
21 CFR 866.5180 - Fecal calprotectin immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... forin vitro diagnostic use as an aid in the diagnosis of inflammatory bowel diseases (IBD), specifically Crohn's disease and ulcerative colitis, and as an aid in differentiation of IBD from irritable bowel...
21 CFR 866.5180 - Fecal calprotectin immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... forin vitro diagnostic use as an aid in the diagnosis of inflammatory bowel diseases (IBD), specifically Crohn's disease and ulcerative colitis, and as an aid in differentiation of IBD from irritable bowel...
21 CFR 866.5180 - Fecal calprotectin immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... forin vitro diagnostic use as an aid in the diagnosis of inflammatory bowel diseases (IBD), specifically Crohn's disease and ulcerative colitis, and as an aid in differentiation of IBD from irritable bowel...
... people with HIV infection and AIDS. Exams and Tests DIAGNOSTIC TESTS These are tests that are done to check if you've ... general, testing is a 2-step process: Screening test. There are several kinds of tests. Some are ...
Computer-aided applications of nanoscale smart materials for biomedical applications.
Rakesh, L; Howell, B A; Chai, M; Mueller, A; Kujawski, M; Fan, D; Ravi, S; Slominski, C
2008-10-01
Nanotechnology has the potential to impact the treatment of many diseases that currently plague society: cancer, AIDS, dementia of various kinds and so on. Nanoscale smart materials, such as carbon nanotubes, C(60), dendrimers and cyclodextrins, hold great promise for use in the development of better diagnostics, drug delivery and the alteration of biological function. Although experimentation is being used to explore the potential offered by these materials, it is by its very nature expensive in terms of time, resources and expertise. Insight with respect to the behavior of these materials in the presence of biological entities can be obtained much more rapidly by molecular dynamics simulation. Furthermore, the results of simulation may be used to guide experimentation so that it is much more productive than it might be in the absence of such information. The interactions of several nanoscale structures with biological macromolecules can already be probed effectively using molecular dynamics simulation. The results obtained should form the basis for significant new developments in the treatment of disease.
ERIC Educational Resources Information Center
Hudson, C. A.
1982-01-01
Advances in factory computerization (computer-aided design and computer-aided manufacturing) are reviewed, including discussions of robotics, human factors engineering, and the sociological impact of automation. (JN)
De Looze, Céline; Beausang, Alan; Cryan, Jane; Loftus, Teresa; Buckley, Patrick G; Farrell, Michael; Looby, Seamus; Reilly, Richard; Brett, Francesca; Kearney, Hugh
2018-05-16
Machine learning methods have been introduced as a computer aided diagnostic tool, with applications to glioma characterisation on MRI. Such an algorithmic approach may provide a useful adjunct for a rapid and accurate diagnosis of a glioma. The aim of this study is to devise a machine learning algorithm that may be used by radiologists in routine practice to aid diagnosis of both: WHO grade and IDH mutation status in de novo gliomas. To evaluate the status quo, we interrogated the accuracy of neuroradiology reports in relation to WHO grade: grade II 96.49% (95% confidence intervals [CI] 0.88, 0.99); III 36.51% (95% CI 0.24, 0.50); IV 72.9% (95% CI 0.67, 0.78). We derived five MRI parameters from the same diagnostic brain scans, in under two minutes per case, and then supplied these data to a random forest algorithm. Machine learning resulted in a high level of accuracy in prediction of tumour grade: grade II/III; area under the receiver operating characteristic curve (AUC) = 98%, sensitivity = 0.82, specificity = 0.94; grade II/IV; AUC = 100%, sensitivity = 1.0, specificity = 1.0; grade III/IV; AUC = 97%, sensitivity = 0.83, specificity = 0.97. Furthermore, machine learning also facilitated the discrimination of IDH status: AUC of 88%, sensitivity = 0.81, specificity = 0.77. These data demonstrate the ability of machine learning to accurately classify diffuse gliomas by both WHO grade and IDH status from routine MRI alone-without significant image processing, which may facilitate usage as a diagnostic adjunct in clinical practice.
Learning-based image preprocessing for robust computer-aided detection
NASA Astrophysics Data System (ADS)
Raghupathi, Laks; Devarakota, Pandu R.; Wolf, Matthias
2013-03-01
Recent studies have shown that low dose computed tomography (LDCT) can be an effective screening tool to reduce lung cancer mortality. Computer-aided detection (CAD) would be a beneficial second reader for radiologists in such cases. Studies demonstrate that while iterative reconstructions (IR) improve LDCT diagnostic quality, it however degrades CAD performance significantly (increased false positives) when applied directly. For improving CAD performance, solutions such as retraining with newer data or applying a standard preprocessing technique may not be suffice due to high prevalence of CT scanners and non-uniform acquisition protocols. Here, we present a learning-based framework that can adaptively transform a wide variety of input data to boost an existing CAD performance. This not only enhances their robustness but also their applicability in clinical workflows. Our solution consists of applying a suitable pre-processing filter automatically on the given image based on its characteristics. This requires the preparation of ground truth (GT) of choosing an appropriate filter resulting in improved CAD performance. Accordingly, we propose an efficient consolidation process with a novel metric. Using key anatomical landmarks, we then derive consistent feature descriptors for the classification scheme that then uses a priority mechanism to automatically choose an optimal preprocessing filter. We demonstrate CAD prototype∗ performance improvement using hospital-scale datasets acquired from North America, Europe and Asia. Though we demonstrated our results for a lung nodule CAD, this scheme is straightforward to extend to other post-processing tools dedicated to other organs and modalities.
A simple Lagrangian forecast system with aviation forecast potential
NASA Technical Reports Server (NTRS)
Petersen, R. A.; Homan, J. H.
1983-01-01
A trajectory forecast procedure is developed which uses geopotential tendency fields obtained from a simple, multiple layer, potential vorticity conservative isentropic model. This model can objectively account for short-term advective changes in the mass field when combined with fine-scale initial analyses. This procedure for producing short-term, upper-tropospheric trajectory forecasts employs a combination of a detailed objective analysis technique, an efficient mass advection model, and a diagnostically proven trajectory algorithm, none of which require extensive computer resources. Results of initial tests are presented, which indicate an exceptionally good agreement for trajectory paths entering the jet stream and passing through an intensifying trough. It is concluded that this technique not only has potential for aiding in route determination, fuel use estimation, and clear air turbulence detection, but also provides an example of the types of short range forecasting procedures which can be applied at local forecast centers using simple algorithms and a minimum of computer resources.
Takita, Toshiya; Tsurumachi, Tamotsu; Ogiso, Bunnai
2011-10-01
This case report presents the endodontic treatment of a maxillary right lateral incisor with a perforating internal resorption in a 50-year-old woman. Radiographically, internal resorption appears as a fairly uniform, radiolucent enlargement of the pulp canal and distortion of the original root canal outline. The use of cone beam computed tomography can help the clinician in making a confirmatory diagnosis and determining the treatment plan before undertaking the actual treatment. After cleaning the root canal space and the resorptive defect by mechanic instrumentation, irrigation, and interim calcium hydroxide dressing, the apical third canal was filled with a gutta-percha point by lateral condensation. The resorptive defect was filled with mineral trioxide aggregate. Follow-up radiographs at 3 years showed adequate repair of the resorption, and the tooth remained asymptomatic.
Automated metastatic brain lesion detection: a computer aided diagnostic and clinical research tool
NASA Astrophysics Data System (ADS)
Devine, Jeremy; Sahgal, Arjun; Karam, Irene; Martel, Anne L.
2016-03-01
The accurate localization of brain metastases in magnetic resonance (MR) images is crucial for patients undergoing stereotactic radiosurgery (SRS) to ensure that all neoplastic foci are targeted. Computer automated tumor localization and analysis can improve both of these tasks by eliminating inter and intra-observer variations during the MR image reading process. Lesion localization is accomplished using adaptive thresholding to extract enhancing objects. Each enhancing object is represented as a vector of features which includes information on object size, symmetry, position, shape, and context. These vectors are then used to train a random forest classifier. We trained and tested the image analysis pipeline on 3D axial contrast-enhanced MR images with the intention of localizing the brain metastases. In our cross validation study and at the most effective algorithm operating point, we were able to identify 90% of the lesions at a precision rate of 60%.
The Effects of Computer-Aided Design Software on Engineering Students' Spatial Visualisation Skills
ERIC Educational Resources Information Center
Kösa, Temel; Karakus, Fatih
2018-01-01
The purpose of this study was to determine the influence of computer-aided design (CAD) software-based instruction on the spatial visualisation skills of freshman engineering students in a computer-aided engineering drawing course. A quasi-experimental design was applied, using the Purdue Spatial Visualization Test-Visualization of Rotations…
Teaching Computer-Aided Design of Fluid Flow and Heat Transfer Engineering Equipment.
ERIC Educational Resources Information Center
Gosman, A. D.; And Others
1979-01-01
Describes a teaching program for fluid mechanics and heat transfer which contains both computer aided learning (CAL) and computer aided design (CAD) components and argues that the understanding of the physical and numerical modeling taught in the CAL course is essential to the proper implementation of CAD. (Author/CMV)
Computer-Presented Organizational/Memory Aids as Instruction for Solving Pico-Fomi Problems.
ERIC Educational Resources Information Center
Steinberg, Esther R.; And Others
1985-01-01
Describes investigation of effectiveness of computer-presented organizational/memory aids (matrix and verbal charts controlled by computer or learner) as instructional technique for solving Pico-Fomi problems, and the acquisition of deductive inference rules when such aids are present. Results indicate chart use control should be adapted to…
Computer-aided design development transition for IPAD environment
NASA Technical Reports Server (NTRS)
Owens, H. G.; Mock, W. D.; Mitchell, J. C.
1980-01-01
The relationship of federally sponsored computer-aided design/computer-aided manufacturing (CAD/CAM) programs to the aircraft life cycle design process, an overview of NAAD'S CAD development program, an evaluation of the CAD design process, a discussion of the current computing environment within which NAAD is developing its CAD system, some of the advantages/disadvantages of the NAAD-IPAD approach, and CAD developments during transition into the IPAD system are discussed.
CAD/CAE Integration Enhanced by New CAD Services Standard
NASA Technical Reports Server (NTRS)
Claus, Russell W.
2002-01-01
A Government-industry team led by the NASA Glenn Research Center has developed a computer interface standard for accessing data from computer-aided design (CAD) systems. The Object Management Group, an international computer standards organization, has adopted this CAD services standard. The new standard allows software (e.g., computer-aided engineering (CAE) and computer-aided manufacturing software to access multiple CAD systems through one programming interface. The interface is built on top of a distributed computing system called the Common Object Request Broker Architecture (CORBA). CORBA allows the CAD services software to operate in a distributed, heterogeneous computing environment.
Design of a receiver operating characteristic (ROC) study of 10:1 lossy image compression
NASA Astrophysics Data System (ADS)
Collins, Cary A.; Lane, David; Frank, Mark S.; Hardy, Michael E.; Haynor, David R.; Smith, Donald V.; Parker, James E.; Bender, Gregory N.; Kim, Yongmin
1994-04-01
The digital archiving system at Madigan Army Medical Center (MAMC) uses a 10:1 lossy data compression algorithm for most forms of computed radiography. A systematic study on the potential effect of lossy image compression on patient care has been initiated with a series of studies focused on specific diagnostic tasks. The studies are based upon the receiver operating characteristic (ROC) method of analysis for diagnostic systems. The null hypothesis is that observer performance with approximately 10:1 compressed and decompressed images is not different from using original, uncompressed images for detecting subtle pathologic findings seen on computed radiographs of bone, chest, or abdomen, when viewed on a high-resolution monitor. Our design involves collecting cases from eight pathologic categories. Truth is determined by committee using confirmatory studies performed during routine clinical practice whenever possible. Software has been developed to aid in case collection and to allow reading of the cases for the study using stand-alone Siemens Litebox workstations. Data analysis uses two methods, ROC analysis and free-response ROC (FROC) methods. This study will be one of the largest ROC/FROC studies of its kind and could benefit clinical radiology practice using PACS technology. The study design and results from a pilot FROC study are presented.
Investigations in Computer-Aided Instruction and Computer-Aided Controls. Final Report.
ERIC Educational Resources Information Center
Rosenberg, R.C.; And Others
These research projects, designed to delve into certain relationships between humans and computers, are focused on computer-assisted instruction and on man-computer interaction. One study demonstrates that within the limits of formal engineering theory, a computer simulated laboratory (Dynamic Systems Laboratory) can be built in which freshmen…
ERIC Educational Resources Information Center
Sinn, John W.
This instructional manual contains five learning activity packets for use in a workshop on computer numerical control for computer-aided manufacturing. The lessons cover the following topics: introduction to computer-aided manufacturing, understanding the lathe, using the computer, computer numerically controlled part programming, and executing a…
Software and resources for computational medicinal chemistry
Liao, Chenzhong; Sitzmann, Markus; Pugliese, Angelo; Nicklaus, Marc C
2011-01-01
Computer-aided drug design plays a vital role in drug discovery and development and has become an indispensable tool in the pharmaceutical industry. Computational medicinal chemists can take advantage of all kinds of software and resources in the computer-aided drug design field for the purposes of discovering and optimizing biologically active compounds. This article reviews software and other resources related to computer-aided drug design approaches, putting particular emphasis on structure-based drug design, ligand-based drug design, chemical databases and chemoinformatics tools. PMID:21707404
Rice, Stephen; McCarley, Jason S
2011-12-01
Automated diagnostic aids prone to false alarms often produce poorer human performance in signal detection tasks than equally reliable miss-prone aids. However, it is not yet clear whether this is attributable to differences in the perceptual salience of the automated aids' misses and false alarms or is the result of inherent differences in operators' cognitive responses to different forms of automation error. The present experiments therefore examined the effects of automation false alarms and misses on human performance under conditions in which the different forms of error were matched in their perceptual characteristics. Young adult participants performed a simulated baggage x-ray screening task while assisted by an automated diagnostic aid. Judgments from the aid were rendered as text messages presented at the onset of each trial, and every trial was followed by a second text message providing response feedback. Thus, misses and false alarms from the aid were matched for their perceptual salience. Experiment 1 found that even under these conditions, false alarms from the aid produced poorer human performance and engendered lower automation use than misses from the aid. Experiment 2, however, found that the asymmetry between misses and false alarms was reduced when the aid's false alarms were framed as neutral messages rather than explicit misjudgments. Results suggest that automation false alarms and misses differ in their inherent cognitive salience and imply that changes in diagnosis framing may allow designers to encourage better use of imperfectly reliable automated aids.
Yang, J; Feng, H L
2018-04-09
With the rapid development of the chair-side computer aided design and computer aided manufacture (CAD/CAM) technology, its accuracy and operability of have been greatly improved in recent years. Chair-side CAD/CAM system may produce all kinds of indirect restorations, and has the advantages of rapid, accurate and stable production. It has become the future development direction of Stomatology. This paper describes the clinical application of the chair-side CAD/CAM technology for anterior aesthetic restorations from the aspects of shade and shape.
Yu, Q
2018-04-09
Computer aided design and computer aided manufacture (CAD/CAM) technology is a kind of oral digital system which is applied to clinical diagnosis and treatment. It overturns the traditional pattern, and provides a solution to restore defect tooth quickly and efficiently. In this paper we mainly discuss the clinical skills of chair-side CAD/CAM system, including tooth preparation, digital impression, the three-dimensional design of prosthesis, numerical control machining, clinical bonding and so on, and review the outcomes of several common kinds of materials at the same time.
Automated detection of diagnostically relevant regions in H&E stained digital pathology slides
NASA Astrophysics Data System (ADS)
Bahlmann, Claus; Patel, Amar; Johnson, Jeffrey; Ni, Jie; Chekkoury, Andrei; Khurd, Parmeshwar; Kamen, Ali; Grady, Leo; Krupinski, Elizabeth; Graham, Anna; Weinstein, Ronald
2012-03-01
We present a computationally efficient method for analyzing H&E stained digital pathology slides with the objective of discriminating diagnostically relevant vs. irrelevant regions. Such technology is useful for several applications: (1) It can speed up computer aided diagnosis (CAD) for histopathology based cancer detection and grading by an order of magnitude through a triage-like preprocessing and pruning. (2) It can improve the response time for an interactive digital pathology workstation (which is usually dealing with several GByte digital pathology slides), e.g., through controlling adaptive compression or prioritization algorithms. (3) It can support the detection and grading workflow for expert pathologists in a semi-automated diagnosis, hereby increasing throughput and accuracy. At the core of the presented method is the statistical characterization of tissue components that are indicative for the pathologist's decision about malignancy vs. benignity, such as, nuclei, tubules, cytoplasm, etc. In order to allow for effective yet computationally efficient processing, we propose visual descriptors that capture the distribution of color intensities observed for nuclei and cytoplasm. Discrimination between statistics of relevant vs. irrelevant regions is learned from annotated data, and inference is performed via linear classification. We validate the proposed method both qualitatively and quantitatively. Experiments show a cross validation error rate of 1.4%. We further show that the proposed method can prune ~90% of the area of pathological slides while maintaining 100% of all relevant information, which allows for a speedup of a factor of 10 for CAD systems.
ERIC Educational Resources Information Center
Wilkinson-Riddle, G. J.; Patel, Ashok
1998-01-01
Discusses courseware development, including intelligent tutoring systems, under the Teaching and Learning Technology Programme and the Byzantium project that was designed to define computer-aided learning performance standards suitable for numerate business subjects; examine reasons to use computer-aided learning; and improve access to educational…
Enhancing Engineering Computer-Aided Design Education Using Lectures Recorded on the PC
ERIC Educational Resources Information Center
McGrann, Roy T. R.
2006-01-01
Computer-Aided Engineering (CAE) is a course that is required during the third year in the mechanical engineering curriculum at Binghamton University. The primary objective of the course is to educate students in the procedures of computer-aided engineering design. The solid modeling and analysis program Pro/Engineer[TM] (PTC[R]) is used as the…
HIV/AIDS, Disability, and Employment. Disability Statistics Report 6.
ERIC Educational Resources Information Center
Sebesta, Douglas S.; LaPlante, Mitchell P.
This report on HIV/AIDS, disability, and employment analyzes data from the AIDS Cost and Services Utilization Survey of 1991-1992, a longitudinal study of 1,949 HIV-infected men and women. The report examines the diagnostic history of people living with HIV and its relation to function, disability, and labor force participation over time. Study…
Cordova: Web-based management of genetic variation data
Ephraim, Sean S.; Anand, Nikhil; DeLuca, Adam P.; Taylor, Kyle R.; Kolbe, Diana L.; Simpson, Allen C.; Azaiez, Hela; Sloan, Christina M.; Shearer, A. Eliot; Hallier, Andrea R.; Casavant, Thomas L.; Scheetz, Todd E.; Smith, Richard J. H.; Braun, Terry A.
2014-01-01
Summary: Cordova is an out-of-the-box solution for building and maintaining an online database of genetic variations integrated with pathogenicity prediction results from popular algorithms. Our primary motivation for developing this system is to aid researchers and clinician–scientists in determining the clinical significance of genetic variations. To achieve this goal, Cordova provides an interface to review and manually or computationally curate genetic variation data as well as share it for clinical diagnostics and the advancement of research. Availability and implementation: Cordova is open source under the MIT license and is freely available for download at https://github.com/clcg/cordova. Contact: sean.ephraim@gmail.com or terry-braun@uiowa.edu PMID:25123904
Foreign body aspiration in adult airways: therapeutic approach
Hewlett, Justin C.; Rickman, Otis B.; Lentz, Robert J.; Prakash, Udaya B.
2017-01-01
Tracheobronchial foreign body (FB) aspiration is an uncommon but potentially life-threatening event in adults. Symptoms typically consist of a choking event followed by cough and dyspnea, however, these findings are inconsistent and symptoms may mimic more chronic lung diseases such as asthma or chronic obstructive pulmonary disease. Chest radiography and computed tomography can provide information regarding the location and characteristics of foreign bodies and aid in diagnosis. Bronchoscopy remains the gold standard for diagnosis and management of FB aspiration. The authors describe the typical clinical presentation, diagnostic evaluation, and bronchoscopic management of foreign bodies in adult airways with a focus on bronchoscopic techniques and potential complications of FB extraction. PMID:29221325
AAFE RADSCAT data reduction programs user's guide
NASA Technical Reports Server (NTRS)
Claassen, J. P.
1976-01-01
Theory, design and operation of the computer programs which automate the reduction of joint radiometer and scatterometer observations are presented. The programs reduce scatterometer measurements to the normalized scattering coefficient; whereas the radiometer measurements are converted into antenna temperatures. The programs are both investigator and user oriented. Supplementary parameters are provided to aid in the interpretation of the observations. A hierarchy of diagnostics is available to evaluate the operation of the instrument, the conduct of the experiments and the quality of the records. General descriptions of the programs and their data products are also presented. This document therefore serves as a user's guide to the programs and is therefore intended to serve both the experimenter and the program operator.
Automated extraction of knowledge for model-based diagnostics
NASA Technical Reports Server (NTRS)
Gonzalez, Avelino J.; Myler, Harley R.; Towhidnejad, Massood; Mckenzie, Frederic D.; Kladke, Robin R.
1990-01-01
The concept of accessing computer aided design (CAD) design databases and extracting a process model automatically is investigated as a possible source for the generation of knowledge bases for model-based reasoning systems. The resulting system, referred to as automated knowledge generation (AKG), uses an object-oriented programming structure and constraint techniques as well as internal database of component descriptions to generate a frame-based structure that describes the model. The procedure has been designed to be general enough to be easily coupled to CAD systems that feature a database capable of providing label and connectivity data from the drawn system. The AKG system is capable of defining knowledge bases in formats required by various model-based reasoning tools.
Key Issues in Instructional Computer Graphics.
ERIC Educational Resources Information Center
Wozny, Michael J.
1981-01-01
Addresses key issues facing universities which plan to establish instructional computer graphics facilities, including computer-aided design/computer aided manufacturing systems, role in curriculum, hardware, software, writing instructional software, faculty involvement, operations, and research. Thirty-seven references and two appendices are…
Diagnostic methods for mastitis in cows are not appropriate for use in humans: commentary.
Kvist, Linda J
2016-01-01
Healthcare workers are now being targeted for marketing of diagnostic tools for mastitis that were developed for the dairy industry and which aim to provide information regarding choice of antibiotic treatment. Meanwhile, scientists are striving to understand how the human microbiome affects health and wellbeing and the importance of maintenance of bacterial balance in the human body. Breast milk supplies a multitude of bacteria to populate the baby's intestinal tract and kick-start the immune system. Researchers propose a paradigm shift in the understanding of bacterial content in breast milk and an alternative paradigm for the understanding of lactational mastitis: there is the beginning of evidence that many cases of lactational mastitis will resolve spontaneously. An international group of researchers is attempting to answer how dietary habits, birth mode, genetics and environmental factors may impact the bacterial content of breast milk. Until we have more comprehensive knowledge about the human milk microbiome, diagnostic aids for identification of women in need of antibiotic therapy for mastitis remain unreliable. Diagnostic aids could lead to the injudicious use of antibiotic therapy, which in turn may rob the infant of bacteria valuable for development of its immune system. The marketing of diagnostic aids for use in human medicine, that were originally developed for use in cows, is neither evidence-based nor good ethical practice.
Computer Programming Languages and Expertise Needed by Practicing Engineers.
ERIC Educational Resources Information Center
Doelling, Irvin
1980-01-01
Discussed is the present engineering computer environment of a large aerospace company recognized as a leader in the application and development of computer-aided design and computer-aided manufacturing techniques. A review is given of the exposure spectrum of engineers to the world of computing, the computer languages used, and the career impacts…
NASA Astrophysics Data System (ADS)
Traverso, A.; Lopez Torres, E.; Fantacci, M. E.; Cerello, P.
2017-05-01
Lung cancer is one of the most lethal types of cancer, because its early diagnosis is not good enough. In fact, the detection of pulmonary nodule, potential lung cancers, in Computed Tomography scans is a very challenging and time-consuming task for radiologists. To support radiologists, researchers have developed Computer-Aided Diagnosis (CAD) systems for the automated detection of pulmonary nodules in chest Computed Tomography scans. Despite the high level of technological developments and the proved benefits on the overall detection performance, the usage of Computer-Aided Diagnosis in clinical practice is far from being a common procedure. In this paper we investigate the causes underlying this discrepancy and present a solution to tackle it: the M5L WEB- and Cloud-based on-demand Computer-Aided Diagnosis. In addition, we prove how the combination of traditional imaging processing techniques with state-of-art advanced classification algorithms allows to build a system whose performance could be much larger than any Computer-Aided Diagnosis developed so far. This outcome opens the possibility to use the CAD as clinical decision support for radiologists.
Computer Assisted Instructional Design for Computer-Based Instruction. Final Report. Working Papers.
ERIC Educational Resources Information Center
Russell, Daniel M.; Pirolli, Peter
Recent advances in artificial intelligence and the cognitive sciences have made it possible to develop successful intelligent computer-aided instructional systems for technical and scientific training. In addition, computer-aided design (CAD) environments that support the rapid development of such computer-based instruction have also been recently…
A review of computer-aided oral and maxillofacial surgery: planning, simulation and navigation.
Chen, Xiaojun; Xu, Lu; Sun, Yi; Politis, Constantinus
2016-11-01
Currently, oral and maxillofacial surgery (OMFS) still poses a significant challenge for surgeons due to the anatomic complexity and limited field of view of the oral cavity. With the great development of computer technologies, he computer-aided surgery has been widely used for minimizing the risks and improving the precision of surgery. Areas covered: The major goal of this paper is to provide a comprehensive reference source of current and future development of computer-aided OMFS including surgical planning, simulation and navigation for relevant researchers. Expert commentary: Compared with the traditional OMFS, computer-aided OMFS overcomes the disadvantage that the treatment on the region of anatomically complex maxillofacial depends almost exclusively on the experience of the surgeon.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Busser, Wendy M. H., E-mail: wendy.busser@radboudumc.nl; Arntz, Mark J.; Jenniskens, Sjoerd F. M.
2015-08-15
PurposeWe assessed whether image registration of cone-beam computed tomography (CT) (CBCT) and contrast-enhanced CT (CE-CT) images indicating the locations of the adrenal veins can aid in increasing the success rate of first-attempts adrenal vein sampling (AVS) and therefore decreasing patient radiation dose.Materials and Methods CBCT scans were acquired in the interventional suite (Philips Allura Xper FD20) and rigidly registered to the vertebra in previously acquired CE-CT. Adrenal vein locations were marked on the CT image and superimposed with live fluoroscopy and digital-subtraction angiography (DSA) to guide the AVS. Seventeen first attempts at AVS were performed with image registration and retrospectivelymore » compared with 15 first attempts without image registration performed earlier by the same 2 interventional radiologists. First-attempt AVS was considered successful when both adrenal vein samples showed representative cortisol levels. Sampling time, dose-area product (DAP), number of DSA runs, fluoroscopy time, and skin dose were recorded.ResultsWithout image registration, the first attempt at sampling was successful in 8 of 15 procedures indicating a success rate of 53.3 %. This increased to 76.5 % (13 of 17) by adding CBCT and CE-CT image registration to AVS procedures (p = 0.266). DAP values (p = 0.001) and DSA runs (p = 0.026) decreased significantly by adding image registration guidance. Sampling and fluoroscopy times and skin dose showed no significant changes.ConclusionGuidance based on registration of CBCT and previously acquired diagnostic CE-CT can aid in enhancing localization of the adrenal veins thereby increasing the success rate of first-attempt AVS with a significant decrease in the number of used DSA runs and, consequently, radiation dose required.« less
Software For Computer-Aided Design Of Control Systems
NASA Technical Reports Server (NTRS)
Wette, Matthew
1994-01-01
Computer Aided Engineering System (CAESY) software developed to provide means to evaluate methods for dealing with users' needs in computer-aided design of control systems. Interpreter program for performing engineering calculations. Incorporates features of both Ada and MATLAB. Designed to be flexible and powerful. Includes internally defined functions, procedures and provides for definition of functions and procedures by user. Written in C language.
NREL Kicks Off Next Phase of Advanced Computer-Aided Battery Engineering |
lithium-ion (Li-ion) batteries, known as a multi-scale multi-domain (GH-MSMD) model framework, was News | NREL Kicks Off Next Phase of Advanced Computer-Aided Battery Engineering NREL Kicks Off Next Phase of Advanced Computer-Aided Battery Engineering March 16, 2016 NREL researcher looks across
Defense Acquisitions Acronyms and Terms
2012-12-01
Computer-Aided Design CADD Computer-Aided Design and Drafting CAE Component Acquisition Executive; Computer-Aided Engineering CAIV Cost As an...Radiation to Ordnance HFE Human Factors Engineering HHA Health Hazard Assessment HNA Host-Nation Approval HNS Host-Nation Support HOL High -Order...Engineering Change Proposal VHSIC Very High Speed Integrated Circuit VLSI Very Large Scale Integration VOC Volatile Organic Compound W WAN Wide
[The automatic iris map overlap technology in computer-aided iridiagnosis].
He, Jia-feng; Ye, Hu-nian; Ye, Miao-yuan
2002-11-01
In the paper, iridology and computer-aided iridiagnosis technologies are briefly introduced and the extraction method of the collarette contour is then investigated. The iris map can be overlapped on the original iris image based on collarette contour extraction. The research on collarette contour extraction and iris map overlap is of great importance to computer-aided iridiagnosis technologies.
New Paradigms for Computer Aids to Invention.
ERIC Educational Resources Information Center
Langston, M. Diane
Many people are interested in computer aids to rhetorical invention and want to know how to evaluate an invention aid, what the criteria are for a good one, and how to assess the trade-offs involved in buying one product or another. The frame of reference for this evaluation is an "old paradigm," which treats the computer as if it were…
Multimedia Image Technology and Computer Aided Manufacturing Engineering Analysis
NASA Astrophysics Data System (ADS)
Nan, Song
2018-03-01
Since the reform and opening up, with the continuous development of science and technology in China, more and more advanced science and technology have emerged under the trend of diversification. Multimedia imaging technology, for example, has a significant and positive impact on computer aided manufacturing engineering in China. From the perspective of scientific and technological advancement and development, the multimedia image technology has a very positive influence on the application and development of computer-aided manufacturing engineering, whether in function or function play. Therefore, this paper mainly starts from the concept of multimedia image technology to analyze the application of multimedia image technology in computer aided manufacturing engineering.
Three-Dimensional Computational Fluid Dynamics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haworth, D.C.; O'Rourke, P.J.; Ranganathan, R.
1998-09-01
Computational fluid dynamics (CFD) is one discipline falling under the broad heading of computer-aided engineering (CAE). CAE, together with computer-aided design (CAD) and computer-aided manufacturing (CAM), comprise a mathematical-based approach to engineering product and process design, analysis and fabrication. In this overview of CFD for the design engineer, our purposes are three-fold: (1) to define the scope of CFD and motivate its utility for engineering, (2) to provide a basic technical foundation for CFD, and (3) to convey how CFD is incorporated into engineering product and process design.
Fused man-machine classification schemes to enhance diagnosis of breast microcalcifications
NASA Astrophysics Data System (ADS)
Andreadis, Ioannis; Sevastianos, Chatzistergos; George, Spyrou; Konstantina, Nikita
2017-11-01
Computer aided diagnosis (CAD x ) approaches are developed towards the effective discrimination between benign and malignant clusters of microcalcifications. Different sources of information are exploited, such as features extracted from the image analysis of the region of interest, features related to the location of the cluster inside the breast, age of the patient and descriptors provided by the radiologists while performing their diagnostic task. A series of different CAD x schemes are implemented, each of which uses a different category of features and adopts a variety of machine learning algorithms and alternative image processing techniques. A novel framework is introduced where these independent diagnostic components are properly combined according to features critical to a radiologist in an attempt to identify the most appropriate CAD x schemes for the case under consideration. An open access database (Digital Database of Screening Mammography (DDSM)) has been elaborated to construct a large dataset with cases of varying subtlety, in order to ensure the development of schemes with high generalization ability, as well as extensive evaluation of their performance. The obtained results indicate that the proposed framework succeeds in improving the diagnostic procedure, as the achieved overall classification performance outperforms all the independent single diagnostic components, as well as the radiologists that assessed the same cases, in terms of accuracy, sensitivity, specificity and area under the curve following receiver operating characteristic analysis.
ERIC Educational Resources Information Center
Insolia, Gerard
This document contains course outlines in computer-aided manufacturing developed for a business-industry technology resource center for firms in eastern Pennsylvania by Northampton Community College. The four units of the course cover the following: (1) introduction to computer-assisted design (CAD)/computer-assisted manufacturing (CAM); (2) CAM…
ERIC Educational Resources Information Center
Meloy, Jim; And Others
1990-01-01
The relationship between computer-aided design (CAD), computer-aided manufacturing (CAM), and computer numerical control (CNC) computer applications is described. Tips for helping educate the CAM buyer on what to look for and what to avoid when searching for the most appropriate instructional CAM package are provided. (KR)
Zhang, Lei; Shen, Shunyao; Yu, Hongbo; Shen, Steve Guofang; Wang, Xudong
2015-07-01
The aim of this study was to investigate the use of computer-aided design and computer-aided manufacturing hydroxyapatite (HA)/epoxide acrylate maleic (EAM) compound construction artificial implants for craniomaxillofacial bone defects. Computed tomography, computer-aided design/computer-aided manufacturing and three-dimensional reconstruction, as well as rapid prototyping were performed in 12 patients between 2008 and 2013. The customized HA/EAM compound artificial implants were manufactured through selective laser sintering using a rapid prototyping machine into the exact geometric shapes of the defect. The HA/EAM compound artificial implants were then implanted during surgical reconstruction. Color-coded superimpositions demonstrated the discrepancy between the virtual plan and achieved results using Geomagic Studio. As a result, the HA/EAM compound artificial bone implants were perfectly matched with the facial areas that needed reconstruction. The postoperative aesthetic and functional results were satisfactory. The color-coded superimpositions demonstrated good consistency between the virtual plan and achieved results. The three-dimensional maximum deviation is 2.12 ± 0.65 mm and the three-dimensional mean deviation is 0.27 ± 0.07 mm. No facial nerve weakness or pain was observed at the follow-up examinations. Only 1 implant had to be removed 2 months after the surgery owing to severe local infection. No other complication was noted during the follow-up period. In conclusion, computer-aided, individually fabricated HA/EAM compound construction artificial implant was a good craniomaxillofacial surgical technique that yielded improved aesthetic results and functional recovery after reconstruction.
Lee, Wan-Sun; Kim, Woong-Chul
2015-01-01
PURPOSE To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (α=.05), respectively. RESULTS The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). CONCLUSION Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 µm). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced. PMID:25932310
Park, Jong-Kyoung; Lee, Wan-Sun; Kim, Hae-Young; Kim, Woong-Chul; Kim, Ji-Hwan
2015-04-01
To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (α=.05), respectively. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 µm). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.
Death Anxiety in Persons with HIV/AIDS: A Systematic Review and Meta-Analysis
ERIC Educational Resources Information Center
Miller, Audrey K.; Lee, Brittany L.; Henderson, Craig E.
2012-01-01
One of the most commonly cited psychological sequelae of HIV/AIDS is anxiety regarding death due to the illness (i.e., death anxiety; DA). However, extant research is inconclusive on several empirical issues, such as DA's relation to HIV/AIDS diagnostic status, the impact of illness-related symptoms on DA, and factors that may protect against DA.…
A Review of Developments in Computer-Based Systems to Image Teeth and Produce Dental Restorations
Rekow, E. Dianne; Erdman, Arthur G.; Speidel, T. Michael
1987-01-01
Computer-aided design and manufacturing (CAD/CAM) make it possible to automate the creation of dental restorations. Currently practiced techniques are described. Three automated systems currently under development are described and compared. Advances in computer-aided design and computer-aided manufacturing (CAD/CAM) provide a new option for dentistry, creating an alternative technique for producing dental restorations. It is possible to create dental restorations that are automatically produced and meet or exceed current requirements for fit and occlusion.
Photogrammetry and computer-aided piping design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keneflick, J.F.; Chirillo, R.D.
1985-02-18
Three-dimensional measurements taken from photographs of a plant model can be digitized and linked with computer-aided piping design. This can short-cut the design and construction of new plants and expedite repair and retrofitting projects. Some designers bridge the gap between model and computer by digitizing from orthographic prints obtained via orthography or the laser scanning of model sections. Such valve or fitting then processed is described in this paper. The marriage of photogrammetry and computer-aided piping design can economically produce such numerical drawings.
Integration of the Execution Support System for the Computer-Aided Prototyping System (CAPS)
1990-09-01
SUPPORT SYSTEM FOR THE COMPUTER -AIDED PROTOTYPING SYSTEM (CAPS) by Frank V. Palazzo September 1990 Thesis Advisor: Luq± Approved for public release...ZATON REPOR ,,.VBE (, 6a NAME OF PERPORMING ORGAN ZAT7ON 6b OFF:CE SYVBOL 7a NAME OF MONITORINC O0-CA’Za- ON Computer Science Department (if applicable...Include Security Classification) Integration of the Execution Support System for the Computer -Aided Prototyping System (C S) 12 PERSONAL AUTHOR(S) Frank V
NASA Astrophysics Data System (ADS)
Arimura, Hidetaka; Yoshiura, Takashi; Kumazawa, Seiji; Tanaka, Kazuhiro; Koga, Hiroshi; Mihara, Futoshi; Honda, Hiroshi; Sakai, Shuji; Toyofuku, Fukai; Higashida, Yoshiharu
2008-03-01
Our goal for this study was to attempt to develop a computer-aided diagnostic (CAD) method for classification of Alzheimer's disease (AD) with atrophic image features derived from specific anatomical regions in three-dimensional (3-D) T1-weighted magnetic resonance (MR) images. Specific regions related to the cerebral atrophy of AD were white matter and gray matter regions, and CSF regions in this study. Cerebral cortical gray matter regions were determined by extracting a brain and white matter regions based on a level set based method, whose speed function depended on gradient vectors in an original image and pixel values in grown regions. The CSF regions in cerebral sulci and lateral ventricles were extracted by wrapping the brain tightly with a zero level set determined from a level set function. Volumes of the specific regions and the cortical thickness were determined as atrophic image features. Average cortical thickness was calculated in 32 subregions, which were obtained by dividing each brain region. Finally, AD patients were classified by using a support vector machine, which was trained by the image features of AD and non-AD cases. We applied our CAD method to MR images of whole brains obtained from 29 clinically diagnosed AD cases and 25 non-AD cases. As a result, the area under a receiver operating characteristic (ROC) curve obtained by our computerized method was 0.901 based on a leave-one-out test in identification of AD cases among 54 cases including 8 AD patients at early stages. The accuracy for discrimination between 29 AD patients and 25 non-AD subjects was 0.840, which was determined at the point where the sensitivity was the same as the specificity on the ROC curve. This result showed that our CAD method based on atrophic image features may be promising for detecting AD patients by using 3-D MR images.
Computer-aided diagnosis of contrast-enhanced spectral mammography: A feasibility study.
Patel, Bhavika K; Ranjbar, Sara; Wu, Teresa; Pockaj, Barbara A; Li, Jing; Zhang, Nan; Lobbes, Mark; Zhang, Bin; Mitchell, J Ross
2018-01-01
To evaluate whether the use of a computer-aided diagnosis-contrast-enhanced spectral mammography (CAD-CESM) tool can further increase the diagnostic performance of CESM compared with that of experienced radiologists. This IRB-approved retrospective study analyzed 50 lesions described on CESM from August 2014 to December 2015. Histopathologic analyses, used as the criterion standard, revealed 24 benign and 26 malignant lesions. An expert breast radiologist manually outlined lesion boundaries on the different views. A set of morphologic and textural features were then extracted from the low-energy and recombined images. Machine-learning algorithms with feature selection were used along with statistical analysis to reduce, select, and combine features. Selected features were then used to construct a predictive model using a support vector machine (SVM) classification method in a leave-one-out-cross-validation approach. The classification performance was compared against the diagnostic predictions of 2 breast radiologists with access to the same CESM cases. Based on the SVM classification, CAD-CESM correctly identified 45 of 50 lesions in the cohort, resulting in an overall accuracy of 90%. The detection rate for the malignant group was 88% (3 false-negative cases) and 92% for the benign group (2 false-positive cases). Compared with the model, radiologist 1 had an overall accuracy of 78% and a detection rate of 92% (2 false-negative cases) for the malignant group and 62% (10 false-positive cases) for the benign group. Radiologist 2 had an overall accuracy of 86% and a detection rate of 100% for the malignant group and 71% (8 false-positive cases) for the benign group. The results of our feasibility study suggest that a CAD-CESM tool can provide complementary information to radiologists, mainly by reducing the number of false-positive findings. Copyright © 2017 Elsevier B.V. All rights reserved.
Using Performance Tools to Support Experiments in HPC Resilience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Naughton, III, Thomas J; Boehm, Swen; Engelmann, Christian
2014-01-01
The high performance computing (HPC) community is working to address fault tolerance and resilience concerns for current and future large scale computing platforms. This is driving enhancements in the programming environ- ments, specifically research on enhancing message passing libraries to support fault tolerant computing capabilities. The community has also recognized that tools for resilience experimentation are greatly lacking. However, we argue that there are several parallels between performance tools and resilience tools . As such, we believe the rich set of HPC performance-focused tools can be extended (repurposed) to benefit the resilience community. In this paper, we describe the initialmore » motivation to leverage standard HPC per- formance analysis techniques to aid in developing diagnostic tools to assist fault tolerance experiments for HPC applications. These diagnosis procedures help to provide context for the system when the errors (failures) occurred. We describe our initial work in leveraging an MPI performance trace tool to assist in provid- ing global context during fault injection experiments. Such tools will assist the HPC resilience community as they extend existing and new application codes to support fault tolerances.« less
Accurate Classification of Diminutive Colorectal Polyps Using Computer-Aided Analysis.
Chen, Peng-Jen; Lin, Meng-Chiung; Lai, Mei-Ju; Lin, Jung-Chun; Lu, Henry Horng-Shing; Tseng, Vincent S
2018-02-01
Narrow-band imaging is an image-enhanced form of endoscopy used to observed microstructures and capillaries of the mucosal epithelium which allows for real-time prediction of histologic features of colorectal polyps. However, narrow-band imaging expertise is required to differentiate hyperplastic from neoplastic polyps with high levels of accuracy. We developed and tested a system of computer-aided diagnosis with a deep neural network (DNN-CAD) to analyze narrow-band images of diminutive colorectal polyps. We collected 1476 images of neoplastic polyps and 681 images of hyperplastic polyps, obtained from the picture archiving and communications system database in a tertiary hospital in Taiwan. Histologic findings from the polyps were also collected and used as the reference standard. The images and data were used to train the DNN. A test set of images (96 hyperplastic and 188 neoplastic polyps, smaller than 5 mm), obtained from patients who underwent colonoscopies from March 2017 through August 2017, was then used to test the diagnostic ability of the DNN-CAD vs endoscopists (2 expert and 4 novice), who were asked to classify the images of the test set as neoplastic or hyperplastic. Their classifications were compared with findings from histologic analysis. The primary outcome measures were diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic time. The accuracy, sensitivity, specificity, PPV, NPV, and diagnostic time were compared among DNN-CAD, the novice endoscopists, and the expert endoscopists. The study was designed to detect a difference of 10% in accuracy by a 2-sided McNemar test. In the test set, the DNN-CAD identified neoplastic or hyperplastic polyps with 96.3% sensitivity, 78.1% specificity, a PPV of 89.6%, and a NPV of 91.5%. Fewer than half of the novice endoscopists classified polyps with a NPV of 90% (their NPVs ranged from 73.9% to 84.0%). DNN-CAD classified polyps as neoplastic or hyperplastic in 0.45 ± 0.07 seconds-shorter than the time required by experts (1.54 ± 1.30 seconds) and nonexperts (1.77 ± 1.37 seconds) (both P < .001). DNN-CAD classified polyps with perfect intra-observer agreement (kappa score of 1). There was a low level of intra-observer and inter-observer agreement in classification among endoscopists. We developed a system called DNN-CAD to identify neoplastic or hyperplastic colorectal polyps less than 5 mm. The system classified polyps with a PPV of 89.6%, and a NPV of 91.5%, and in a shorter time than endoscopists. This deep-learning model has potential for not only endoscopic image recognition but for other forms of medical image analysis, including sonography, computed tomography, and magnetic resonance images. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
Computer-aided Instructional System for Transmission Line Simulation.
ERIC Educational Resources Information Center
Reinhard, Erwin A.; Roth, Charles H., Jr.
A computer-aided instructional system has been developed which utilizes dynamic computer-controlled graphic displays and which requires student interaction with a computer simulation in an instructional mode. A numerical scheme has been developed for digital simulation of a uniform, distortionless transmission line with resistive terminations and…
Proceedings of the Workshop on Computational Aspects in the Control of Flexible Systems, part 1
NASA Technical Reports Server (NTRS)
Taylor, Lawrence W., Jr. (Compiler)
1989-01-01
Control/Structures Integration program software needs, computer aided control engineering for flexible spacecraft, computer aided design, computational efficiency and capability, modeling and parameter estimation, and control synthesis and optimization software for flexible structures and robots are among the topics discussed.
Computer aided field editing in the DHS context: the Turkey experiment.
Cushing, J; Loaiza, E
1994-01-01
"In this study two types of field editing used during the Turkey Demographic and Health Survey are compared. These two types of editing are computer aided field editing and manual editing. It is known that manual editing by field editors is a tedious job in which errors especially on skip questions can be missed; however, with the aid of computers field editors could quickly find all occasions on which an interviewer incorrectly followed a skip instruction. At the end of the experiment it has been found...that the field editing done with the aid of a notebook computer was consistently better than that done in the standard manual manner." (SUMMARY IN TUR) excerpt
Quality indexing with computer-aided lexicography
NASA Technical Reports Server (NTRS)
Buchan, Ronald L.
1992-01-01
Indexing with computers is a far cry from indexing with the first indexing tool, the manual card sorter. With the aid of computer-aided lexicography, both indexing and indexing tools can provide standardization, consistency, and accuracy, resulting in greater quality control than ever before. A brief survey of computer activity in indexing is presented with detailed illustrations from NASA activity. Applications from techniques mentioned, such as Retrospective Indexing (RI), can be made to many indexing systems. In addition to improving the quality of indexing with computers, the improved efficiency with which certain tasks can be done is demonstrated.
Gilardi, G. L.
1971-01-01
Antimicrobial susceptibility data regarding nonfermentative, gram-negative bacteria (Pseudomonas, Alcaligenes, Acinetobacter, Moraxella, Flavobacterium) are presented showing that the antibiograms of most species examined can be used as an important auxillary aid in their differentiation. PMID:5132093
COMPUTER-AIDED DATA ACQUISITION FOR COMBUSTION EXPERIMENTS
The article describes the use of computer-aided data acquisition techniques to aid the research program of the Combustion Research Branch (CRB) of the U.S. EPA's Air and Energy Engineering Research Laboratory (AEERL) in Research Triangle Park, NC, in particular on CRB's bench-sca...
Computer-aided decision support systems for endoscopy in the gastrointestinal tract: a review.
Liedlgruber, Michael; Uhl, Andreas
2011-01-01
Today, medical endoscopy is a widely used procedure to inspect the inner cavities of the human body. The advent of endoscopic imaging techniques-allowing the acquisition of images or videos-created the possibility for the development of the whole new branch of computer-aided decision support systems. Such systems aim at helping physicians to identify possibly malignant abnormalities more accurately. At the beginning of this paper, we give a brief introduction to the history of endoscopy, followed by introducing the main types of endoscopes which emerged so far (flexible endoscope, wireless capsule endoscope, and confocal laser endomicroscope). We then give a brief introduction to computer-aided decision support systems specifically targeted at endoscopy in the gastrointestinal tract. Then we present general facts and figures concerning computer-aided decision support systems and summarize work specifically targeted at computer-aided decision support in the gastrointestinal tract. This summary is followed by a discussion of some common issues concerning the approaches reviewed and suggestions of possible ways to resolve them.
McKenna, Matthew T.; Wang, Shijun; Nguyen, Tan B.; Burns, Joseph E.; Petrick, Nicholas; Summers, Ronald M.
2012-01-01
Computer-aided detection (CAD) systems have been shown to improve the diagnostic performance of CT colonography (CTC) in the detection of premalignant colorectal polyps. Despite the improvement, the overall system is not optimal. CAD annotations on true lesions are incorrectly dismissed, and false positives are misinterpreted as true polyps. Here, we conduct an observer performance study utilizing distributed human intelligence in the form of anonymous knowledge workers (KWs) to investigate human performance in classifying polyp candidates under different presentation strategies. We evaluated 600 polyp candidates from 50 patients, each case having at least one polyp • 6 mm, from a large database of CTC studies. Each polyp candidate was labeled independently as a true or false polyp by 20 KWs and an expert radiologist. We asked each labeler to determine whether the candidate was a true polyp after looking at a single 3D-rendered image of the candidate and after watching a video fly-around of the candidate. We found that distributed human intelligence improved significantly when presented with the additional information in the video fly-around. We noted that performance degraded with increasing interpretation time and increasing difficulty, but distributed human intelligence performed better than our CAD classifier for “easy” and “moderate” polyp candidates. Further, we observed numerous parallels between the expert radiologist and the KWs. Both showed similar improvement in classification moving from single-image to video interpretation. Additionally, difficulty estimates obtained from the KWs using an expectation maximization algorithm correlated well with the difficulty rating assigned by the expert radiologist. Our results suggest that distributed human intelligence is a powerful tool that will aid in the development of CAD for CTC. PMID:22705287
Computer-aided diagnosis of pulmonary diseases using x-ray darkfield radiography
NASA Astrophysics Data System (ADS)
Einarsdóttir, Hildur; Yaroshenko, Andre; Velroyen, Astrid; Bech, Martin; Hellbach, Katharina; Auweter, Sigrid; Yildirim, Önder; Meinel, Felix G.; Eickelberg, Oliver; Reiser, Maximilian; Larsen, Rasmus; Kjær Ersbøll, Bjarne; Pfeiffer, Franz
2015-12-01
In this work we develop a computer-aided diagnosis (CAD) scheme for classification of pulmonary disease for grating-based x-ray radiography. In addition to conventional transmission radiography, the grating-based technique provides a dark-field imaging modality, which utilizes the scattering properties of the x-rays. This modality has shown great potential for diagnosing early stage emphysema and fibrosis in mouse lungs in vivo. The CAD scheme is developed to assist radiologists and other medical experts to develop new diagnostic methods when evaluating grating-based images. The scheme consists of three stages: (i) automatic lung segmentation; (ii) feature extraction from lung shape and dark-field image intensities; (iii) classification between healthy, emphysema and fibrosis lungs. A study of 102 mice was conducted with 34 healthy, 52 emphysema and 16 fibrosis subjects. Each image was manually annotated to build an experimental dataset. System performance was assessed by: (i) determining the quality of the segmentations; (ii) validating emphysema and fibrosis recognition by a linear support vector machine using leave-one-out cross-validation. In terms of segmentation quality, we obtained an overlap percentage (Ω) 92.63 ± 3.65%, Dice Similarity Coefficient (DSC) 89.74 ± 8.84% and Jaccard Similarity Coefficient 82.39 ± 12.62%. For classification, the accuracy, sensitivity and specificity of diseased lung recognition was 100%. Classification between emphysema and fibrosis resulted in an accuracy of 93%, whilst the sensitivity was 94% and specificity 88%. In addition to the automatic classification of lungs, deviation maps created by the CAD scheme provide a visual aid for medical experts to further assess the severity of pulmonary disease in the lung, and highlights regions affected.
McKenna, Matthew T; Wang, Shijun; Nguyen, Tan B; Burns, Joseph E; Petrick, Nicholas; Summers, Ronald M
2012-08-01
Computer-aided detection (CAD) systems have been shown to improve the diagnostic performance of CT colonography (CTC) in the detection of premalignant colorectal polyps. Despite the improvement, the overall system is not optimal. CAD annotations on true lesions are incorrectly dismissed, and false positives are misinterpreted as true polyps. Here, we conduct an observer performance study utilizing distributed human intelligence in the form of anonymous knowledge workers (KWs) to investigate human performance in classifying polyp candidates under different presentation strategies. We evaluated 600 polyp candidates from 50 patients, each case having at least one polyp ≥6 mm, from a large database of CTC studies. Each polyp candidate was labeled independently as a true or false polyp by 20 KWs and an expert radiologist. We asked each labeler to determine whether the candidate was a true polyp after looking at a single 3D-rendered image of the candidate and after watching a video fly-around of the candidate. We found that distributed human intelligence improved significantly when presented with the additional information in the video fly-around. We noted that performance degraded with increasing interpretation time and increasing difficulty, but distributed human intelligence performed better than our CAD classifier for "easy" and "moderate" polyp candidates. Further, we observed numerous parallels between the expert radiologist and the KWs. Both showed similar improvement in classification moving from single-image to video interpretation. Additionally, difficulty estimates obtained from the KWs using an expectation maximization algorithm correlated well with the difficulty rating assigned by the expert radiologist. Our results suggest that distributed human intelligence is a powerful tool that will aid in the development of CAD for CTC. Copyright © 2012. Published by Elsevier B.V.
Computer-aided diagnosis with textural features for breast lesions in sonograms.
Chen, Dar-Ren; Huang, Yu-Len; Lin, Sheng-Hsiung
2011-04-01
Computer-aided diagnosis (CAD) systems provided second beneficial support reference and enhance the diagnostic accuracy. This paper was aimed to develop and evaluate a CAD with texture analysis in the classification of breast tumors for ultrasound images. The ultrasound (US) dataset evaluated in this study composed of 1020 sonograms of region of interest (ROI) subimages from 255 patients. Two-view sonogram (longitudinal and transverse views) and four different rectangular regions were utilized to analyze each tumor. Six practical textural features from the US images were performed to classify breast tumors as benign or malignant. However, the textural features always perform as a high dimensional vector; high dimensional vector is unfavorable to differentiate breast tumors in practice. The principal component analysis (PCA) was used to reduce the dimension of textural feature vector and then the image retrieval technique was performed to differentiate between benign and malignant tumors. In the experiments, all the cases were sampled with k-fold cross-validation (k=10) to evaluate the performance with receiver operating characteristic (ROC) curve. The area (A(Z)) under the ROC curve for the proposed CAD system with the specific textural features was 0.925±0.019. The classification ability for breast tumor with textural information is satisfactory. This system differentiates benign from malignant breast tumors with a good result and is therefore clinically useful to provide a second opinion. Copyright © 2010 Elsevier Ltd. All rights reserved.
2018-03-30
ARL-TR-8336 ● MAR 2018 US Army Research Laboratory Manipulating the Geometric Computer-aided Design of the Operational...so designated by other authorized documents. Citation of manufacturer’s or trade names does not constitute an official endorsement or approval of...Army Research Laboratory Manipulating the Geometric Computer-aided Design of the Operational Requirements-based Casualty Assessment Model within
Increasing productivity of the McAuto CAD/CAE system by user-specific applications programming
NASA Technical Reports Server (NTRS)
Plotrowski, S. M.; Vu, T. H.
1985-01-01
Significant improvements in the productivity of the McAuto Computer-Aided Design/Computer-Aided Engineering (CAD/CAE) system were achieved by applications programming using the system's own Graphics Interactive Programming language (GRIP) and the interface capabilities with the main computer on which the system resides. The GRIP programs for creating springs, bar charts, finite element model representations and aiding management planning are presented as examples.
Possible Computer Vision Systems and Automated or Computer-Aided Edging and Trimming
Philip A. Araman
1990-01-01
This paper discusses research which is underway to help our industry reduce costs, increase product volume and value recovery, and market more accurately graded and described products. The research is part of a team effort to help the hardwood sawmill industry automate with computer vision systems, and computer-aided or computer controlled processing. This paper...
Features of Computer-Based Decision Aids: Systematic Review, Thematic Synthesis, and Meta-Analyses.
Syrowatka, Ania; Krömker, Dörthe; Meguerditchian, Ari N; Tamblyn, Robyn
2016-01-26
Patient information and education, such as decision aids, are gradually moving toward online, computer-based environments. Considerable research has been conducted to guide content and presentation of decision aids. However, given the relatively new shift to computer-based support, little attention has been given to how multimedia and interactivity can improve upon paper-based decision aids. The first objective of this review was to summarize published literature into a proposed classification of features that have been integrated into computer-based decision aids. Building on this classification, the second objective was to assess whether integration of specific features was associated with higher-quality decision making. Relevant studies were located by searching MEDLINE, Embase, CINAHL, and CENTRAL databases. The review identified studies that evaluated computer-based decision aids for adults faced with preference-sensitive medical decisions and reported quality of decision-making outcomes. A thematic synthesis was conducted to develop the classification of features. Subsequently, meta-analyses were conducted based on standardized mean differences (SMD) from randomized controlled trials (RCTs) that reported knowledge or decisional conflict. Further subgroup analyses compared pooled SMDs for decision aids that incorporated a specific feature to other computer-based decision aids that did not incorporate the feature, to assess whether specific features improved quality of decision making. Of 3541 unique publications, 58 studies met the target criteria and were included in the thematic synthesis. The synthesis identified six features: content control, tailoring, patient narratives, explicit values clarification, feedback, and social support. A subset of 26 RCTs from the thematic synthesis was used to conduct the meta-analyses. As expected, computer-based decision aids performed better than usual care or alternative aids; however, some features performed better than others. Integration of content control improved quality of decision making (SMD 0.59 vs 0.23 for knowledge; SMD 0.39 vs 0.29 for decisional conflict). In contrast, tailoring reduced quality of decision making (SMD 0.40 vs 0.71 for knowledge; SMD 0.25 vs 0.52 for decisional conflict). Similarly, patient narratives also reduced quality of decision making (SMD 0.43 vs 0.65 for knowledge; SMD 0.17 vs 0.46 for decisional conflict). Results were varied for different types of explicit values clarification, feedback, and social support. Integration of media rich or interactive features into computer-based decision aids can improve quality of preference-sensitive decision making. However, this is an emerging field with limited evidence to guide use. The systematic review and thematic synthesis identified features that have been integrated into available computer-based decision aids, in an effort to facilitate reporting of these features and to promote integration of such features into decision aids. The meta-analyses and associated subgroup analyses provide preliminary evidence to support integration of specific features into future decision aids. Further research can focus on clarifying independent contributions of specific features through experimental designs and refining the designs of features to improve effectiveness.
Computer Skill Acquisition and Retention: The Effects of Computer-Aided Self-Explanation
ERIC Educational Resources Information Center
Chi, Tai-Yin
2016-01-01
This research presents an experimental study to determine to what extent computer skill learners can benefit from generating self-explanation with the aid of different computer-based visualization technologies. Self-explanation was stimulated with dynamic visualization (Screencast), static visualization (Screenshot), or verbal instructions only,…
Partovi, Sasan; Yuh, Roger; Pirozzi, Sara; Lu, Ziang; Couturier, Spencer; Grosse, Ulrich; Schluchter, Mark D; Nelson, Aaron; Jones, Robert; O’Donnell, James K; Faulhaber, Peter
2017-01-01
The objective of this study was to assess the ability of a quantitative software-aided approach to improve the diagnostic accuracy of 18F FDG PET for Alzheimer’s dementia over visual analysis alone. Twenty normal subjects (M:F-12:8; mean age 80.6 years) and twenty mild AD subjects (M:F-12:8; mean age 70.6 years) with 18F FDG PET scans were obtained from the ADNI database. Three blinded readers interpreted these PET images first using a visual qualitative approach and then using a quantitative software-aided approach. Images were classified on two five-point scales based on normal/abnormal (1-definitely normal; 5-definitely abnormal) and presence of AD (1-definitely not AD; 5-definitely AD). Diagnostic sensitivity, specificity, and accuracy for both approaches were compared based on the aforementioned scales. The sensitivity, specificity, and accuracy for the normal vs. abnormal readings of all readers combined were higher when comparing the software-aided vs. visual approach (sensitivity 0.93 vs. 0.83 P = 0.0466; specificity 0.85 vs. 0.60 P = 0.0005; accuracy 0.89 vs. 0.72 P<0.0001). The specificity and accuracy for absence vs. presence of AD of all readers combined were higher when comparing the software-aided vs. visual approach (specificity 0.90 vs. 0.70 P = 0.0008; accuracy 0.81 vs. 0.72 P = 0.0356). Sensitivities of the software-aided and visual approaches did not differ significantly (0.72 vs. 0.73 P = 0.74). The quantitative software-aided approach appears to improve the performance of 18F FDG PET for the diagnosis of mild AD. It may be helpful for experienced 18F FDG PET readers analyzing challenging cases. PMID:28123864
New teaching aid “Physical Methods of Medical Introscopy”
NASA Astrophysics Data System (ADS)
Ulin, S. E.
2017-01-01
Description of a new teaching aid, in which new methods of reconstruction of hidden images by means of nuclear magnetic resonance, X-gamma-ray, and ultrasonic tomography, is presented. The diagnostics and therapy methods of various oncological diseases with the use of medicine proton and ions beams, as well as neutron capture therapy, are considered. The new teaching aid is intended for senior students and postgraduates.
[A new system of testing visual performance based on the cylindrical lens screen].
Doege, E; Krause, O
1983-09-01
Using a special microoptical screen as a test-picture coating, a method for testing binocular function was developed. It offers the advantage of providing a separate visual impression to each eye from a diagnostic picture without using any device in front of the eyes. The person tested is unaware of this procedure, of which the diagnostic plate gives no hint. In addition to a description of its numerous uses and diagnostic possibilities, fusion pictures suitable for screening tests are described: Each eye is offered a separate impression with a completely different content. If fusion occurs correctly, a third motif with an entirely new meaning emerges. Several years of experience with this effective system (naked-eye tests) resulted in aids which are listed in the final section of the paper: exercise aids used for preparing the persons tested (especially infants) in the waiting room, recognition aids for the examination, and a partially kinetic picture for rapid, simple and very convincing representation of adjusting movements and of the squint position in cases of concomitant squint.
Jan Wiedenbeck; Jeff Parsons; Bruce Beeken
2009-01-01
Computer-aided manufacturing (CAM), in which computer-aided design (CAD) and computer numerically controlled (CNC) machining are integrated for the production of parts, became a viable option for the woodworking industry in the 1980s.
WINCADRE (COMPUTER-AIDED DATA REVIEW AND EVALUATION)
WinCADRE (Computer-Aided Data Review and Evaluation) is a Windows -based program designed for computer-assisted data validation. WinCADRE is a powerful tool which significantly decreases data validation turnaround time. The electronic-data-deliverable format has been designed ...
NASA Technical Reports Server (NTRS)
Litvin, Faydor L.; Tsay, Chung-Biau
1987-01-01
The authors have proposed a method for the generation of circular arc helical gears which is based on the application of standard equipment, worked out all aspects of the geometry of the gears, proposed methods for the computer aided simulation of conditions of meshing and bearing contact, investigated the influence of manufacturing and assembly errors, and proposed methods for the adjustment of gears to these errors. The results of computer aided solutions are illustrated with computer graphics.
Computer-aided drug discovery.
Bajorath, Jürgen
2015-01-01
Computational approaches are an integral part of interdisciplinary drug discovery research. Understanding the science behind computational tools, their opportunities, and limitations is essential to make a true impact on drug discovery at different levels. If applied in a scientifically meaningful way, computational methods improve the ability to identify and evaluate potential drug molecules, but there remain weaknesses in the methods that preclude naïve applications. Herein, current trends in computer-aided drug discovery are reviewed, and selected computational areas are discussed. Approaches are highlighted that aid in the identification and optimization of new drug candidates. Emphasis is put on the presentation and discussion of computational concepts and methods, rather than case studies or application examples. As such, this contribution aims to provide an overview of the current methodological spectrum of computational drug discovery for a broad audience.
Oh, Eun-Yeong; Lerwill, Melinda F.; Brachtel, Elena F.; Jones, Nicholas C.; Knoblauch, Nicholas W.; Montaser-Kouhsari, Laleh; Johnson, Nicole B.; Rao, Luigi K. F.; Faulkner-Jones, Beverly; Wilbur, David C.; Schnitt, Stuart J.; Beck, Andrew H.
2014-01-01
The categorization of intraductal proliferative lesions of the breast based on routine light microscopic examination of histopathologic sections is in many cases challenging, even for experienced pathologists. The development of computational tools to aid pathologists in the characterization of these lesions would have great diagnostic and clinical value. As a first step to address this issue, we evaluated the ability of computational image analysis to accurately classify DCIS and UDH and to stratify nuclear grade within DCIS. Using 116 breast biopsies diagnosed as DCIS or UDH from the Massachusetts General Hospital (MGH), we developed a computational method to extract 392 features corresponding to the mean and standard deviation in nuclear size and shape, intensity, and texture across 8 color channels. We used L1-regularized logistic regression to build classification models to discriminate DCIS from UDH. The top-performing model contained 22 active features and achieved an AUC of 0.95 in cross-validation on the MGH data-set. We applied this model to an external validation set of 51 breast biopsies diagnosed as DCIS or UDH from the Beth Israel Deaconess Medical Center, and the model achieved an AUC of 0.86. The top-performing model contained active features from all color-spaces and from the three classes of features (morphology, intensity, and texture), suggesting the value of each for prediction. We built models to stratify grade within DCIS and obtained strong performance for stratifying low nuclear grade vs. high nuclear grade DCIS (AUC = 0.98 in cross-validation) with only moderate performance for discriminating low nuclear grade vs. intermediate nuclear grade and intermediate nuclear grade vs. high nuclear grade DCIS (AUC = 0.83 and 0.69, respectively). These data show that computational pathology models can robustly discriminate benign from malignant intraductal proliferative lesions of the breast and may aid pathologists in the diagnosis and classification of these lesions. PMID:25490766
Biomedical engineering at Sandia National Laboratories
NASA Astrophysics Data System (ADS)
Zanner, Mary Ann
1994-12-01
The potential exists to reduce or control some aspects of the U.S. health care expenditure without compromising health care delivery by developing carefully selected technologies which impact favorably on the health care system. A focused effort to develop such technologies is underway at Sandia National Laboratories. As a DOE National Laboratory, Sandia possesses a wealth of engineering and scientific expertise that can be readily applied to this critical national need. Appropriate mechanisms currently exist to allow transfer of technology from the laboratory to the private sector. Sandia's Biomedical Engineering Initiative addresses the development of properly evaluated, cost-effective medical technologies through team collaborations with the medical community. Technology development is subjected to certain criteria including wide applicability, earlier diagnoses, increased efficiency, cost-effectiveness and dual-use. Examples of Sandia's medical technologies include a noninvasive blood glucose sensor, computer aided mammographic screening, noninvasive fetal oximetry and blood gas measurement, burn diagnostics and laser debridement, telerobotics and ultrasonic scanning for prosthetic devices. Sandia National Laboratories has the potential to aid in directing medical technology development efforts which emphasize health care needs, earlier diagnosis, cost containment and improvement of the quality of life.
Computer-Aided Engineering Education at the K.U. Leuven.
ERIC Educational Resources Information Center
Snoeys, R.; Gobin, R.
1987-01-01
Describes some recent initiatives and developments in the computer-aided design program in the engineering faculty of the Katholieke Universiteit Leuven (Belgium). Provides a survey of the engineering curriculum, the computer facilities, and the main software packages available. (TW)
Software Tools for Shipbuilding Productivity
1984-12-01
shipbuilding, is that design, manufacturing and robotic technology applications to shipbuilding have been proven. all aspects of shipbuilding is now a task...technical information about the process of Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) effectively has been a problem of serious and...Design (CAD) 3.4.1 CAD System Components 3.4.2 CAD System Benefits 3.4.3 New and Future CAD Technologies Computer Aided Manufacturing (CAM) 3.5.1 CAM
Lin, Wei-Shao; Metz, Michael J; Pollini, Adrien; Ntounis, Athanasios; Morton, Dean
2014-12-01
This dental technique report describes a digital workflow with digital data acquisition at the implant level, computer-aided design and computer-aided manufacturing fabricated, tissue-colored, anodized titanium framework, individually luted zirconium oxide restorations, and autopolymerizing injection-molded acrylic resin to fabricate an implant-supported, metal-ceramic-resin fixed complete dental prosthesis in an edentulous mandible. The 1-step computer-aided design and computer-aided manufacturing fabrication of titanium framework and zirconium oxide restorations can provide a cost-effective alternative to the conventional metal-resin fixed complete dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Watson, Jason; Hatamleh, Muhanad; Alwahadni, Ahed; Srinivasan, Dilip
2014-05-01
Patients with significant craniofacial asymmetry may have functional problems associated with their occlusion and aesthetic concerns related to the imbalance in soft and hard tissue profiles. This report details a case of facial asymmetry secondary to left mandible angle deficiency due to undergoing previous radiotherapy. We describe the correction of the bony deformity using computer aided design/computer aided manufacturing custom-made titanium onlay using novel direct metal laser sintering. The direct metal laser sintering onlay proved a very accurate operative fit and showed a good aesthetic correction of the bony defect with no reported complications postoperatively. It is a useful low-morbidity technique, and there is no resorption or associated donor-site complications.
Wauters, Lauri D J; Miguel-Moragas, Joan San; Mommaerts, Maurice Y
2015-11-01
To gain insight into the methodology of different computer-aided design-computer-aided manufacturing (CAD-CAM) applications for the reconstruction of cranio-maxillo-facial (CMF) defects. We reviewed and analyzed the available literature pertaining to CAD-CAM for use in CMF reconstruction. We proposed a classification system of the techniques of implant and cutting, drilling, and/or guiding template design and manufacturing. The system consisted of 4 classes (I-IV). These classes combine techniques used for both the implant and template to most accurately describe the methodology used. Our classification system can be widely applied. It should facilitate communication and immediate understanding of the methodology of CAD-CAM applications for the reconstruction of CMF defects.
Andreiuolo, Rafael Ferrone; Sabrosa, Carlos Eduardo; Dias, Katia Regina H Cervantes
2013-09-01
The use of bi-layered all-ceramic crowns has continuously grown since the introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia cores. Unfortunately, despite the outstanding mechanical properties of zirconia, problems related to porcelain cracking or chipping remain. One of the reasons for this is that ceramic copings are usually milled to uniform thicknesses of 0.3-0.6 mm around the whole tooth preparation. This may not provide uniform thickness or appropriate support for the veneering porcelain. To prevent these problems, the dual-scan technique demonstrates an alternative that allows the restorative team to customize zirconia CAD/CAM frameworks with adequate porcelain thickness and support in a simple manner.
Cordova: web-based management of genetic variation data.
Ephraim, Sean S; Anand, Nikhil; DeLuca, Adam P; Taylor, Kyle R; Kolbe, Diana L; Simpson, Allen C; Azaiez, Hela; Sloan, Christina M; Shearer, A Eliot; Hallier, Andrea R; Casavant, Thomas L; Scheetz, Todd E; Smith, Richard J H; Braun, Terry A
2014-12-01
Cordova is an out-of-the-box solution for building and maintaining an online database of genetic variations integrated with pathogenicity prediction results from popular algorithms. Our primary motivation for developing this system is to aid researchers and clinician-scientists in determining the clinical significance of genetic variations. To achieve this goal, Cordova provides an interface to review and manually or computationally curate genetic variation data as well as share it for clinical diagnostics and the advancement of research. Cordova is open source under the MIT license and is freely available for download at https://github.com/clcg/cordova. Published by Oxford University Press. This work is written by US Government employees and is in the public domain in the US.
NASA Technical Reports Server (NTRS)
Brandli, A. E.; Eckelkamp, R. E.; Kelly, C. M.; Mccandless, W.; Rue, D. L.
1990-01-01
The objective of an operations management system is to provide an orderly and efficient method to operate and maintain aerospace vehicles. Concepts are described for an operations management system and the key technologies are highlighted which will be required if this capability is brought to fruition. Without this automation and decision aiding capability, the growing complexity of avionics will result in an unmanageable workload for the operator, ultimately threatening mission success or survivability of the aircraft or space system. The key technologies include expert system application to operational tasks such as replanning, equipment diagnostics and checkout, global system management, and advanced man machine interfaces. The economical development of operations management systems, which are largely software, will require advancements in other technological areas such as software engineering and computer hardware.
LLE review, volume 73. Quarterly report, October 1997--December 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-04-01
This progress report contains discussion on the following topics: A high-bandwidth electrical-waveform generator based on aperture-coupled striplines for OMEGA pulse-shaping applications; sweep deflection circuit development using computer-aided circuit design for the OMEGA multichannel streak camera; D-{sup 3}He protons as a diagnostic for target {rho}R; growth rates of the ablative Rayleigh-Taylor instability in inertial confinement fusion; three-dimensional analysis of the power transfer between crossed laser beams; characterization of freestanding polymer films for application in 351-nm, high-peak-power laser systems; subsurface damage in microgrinding optical glasses; bound-abrasive polishers for optical glass; and color gamut of cholesteric liquid crystal films and flakes by standardmore » colorimetry.« less
Apparatus for proton radiography
Martin, Ronald L.
1976-01-01
An apparatus for effecting diagnostic proton radiography of patients in hospitals comprises a source of negative hydrogen ions, a synchrotron for accelerating the negative hydrogen ions to a predetermined energy, a plurality of stations for stripping extraction of a radiography beam of protons, means for sweeping the extracted beam to cover a target, and means for measuring the residual range, residual energy, or percentage transmission of protons that pass through the target. The combination of information identifying the position of the beam with information about particles traversing the subject and the back absorber is performed with the aid of a computer to provide a proton radiograph of the subject. In an alternate embodiment of the invention, a back absorber comprises a plurality of scintillators which are coupled to detectors.
Computer Simulated Visual and Tactile Feedback as an Aid to Manipulator and Vehicle Control,
1981-05-08
STATEMENT ........................ 8 Artificial Intellegence Versus Supervisory Control ....... 8 Computer Generation of Operator Feedback...operator. Artificial Intelligence Versus Supervisory Control The use of computers to aid human operators can be divided into two catagories: artificial ...operator. Artificial intelligence ( A. I. ) attempts to give the computer maximum intelligence and to replace all operator functions by the computer
Laffey, John G; Pham, Tài; Bellani, Giacomo
2017-02-01
Timely recognition of acute respiratory distress syndrome (ARDS) may allow for more prompt management and less exacerbation of lung injury. However, the absence of a diagnostic test for ARDS means that the diagnosis of ARDS requires clinician recognition in what is usually a complicated and evolving illness. We review data concerning the extent of recognition of ARDS in the era of the Berlin definition of ARDS. ARDS continues to be under-recognized - even in the era of the more recent 'Berlin' definition, and significant delay in its recognition is common. Factors contributing to under-recognition may include the complexity of ARDS biology, low specificity of the consensus (diagnostic) criteria, and concerns about reliable interpretation of the chest radiograph. Understandably, 'external' factors are also at play: ICU occupancy and higher patient to clinician ratio impair recognition of ARDS. Timely recognition of ARDS appears important, as it is associated with the use of higher PEEP, prone positioning and neuromuscular blockade which can lower mortality. Computer-aided decision tools seem diagnostically useful, and together with the integration of reliable biomarkers, may further enhance and speed recognition of this syndrome. Significant numbers of patients with ARDS are still unrecognized by clinicians in the era of the Berlin definition of ARDS, with potentially important consequences for patient management and outcome.
Virtual Reality versus Computer-Aided Exposure Treatments for Fear of Flying
ERIC Educational Resources Information Center
Tortella-Feliu, Miquel; Botella, Cristina; Llabres, Jordi; Breton-Lopez, Juana Maria; del Amo, Antonio Riera; Banos, Rosa M.; Gelabert, Joan M.
2011-01-01
Evidence is growing that two modalities of computer-based exposure therapies--virtual reality and computer-aided psychotherapy--are effective in treating anxiety disorders, including fear of flying. However, they have not yet been directly compared. The aim of this study was to analyze the efficacy of three computer-based exposure treatments for…
The Implications of Cognitive Psychology for Computer-Based Learning Tools.
ERIC Educational Resources Information Center
Kozma, Robert B.
1987-01-01
Defines cognitive computer tools as software programs that use the control capabilities of computers to amplify, extend, or enhance human cognition; suggests seven ways in which computers can aid learning; and describes the "Learning Tool," a software package for the Apple Macintosh microcomputer that is designed to aid learning of…
Artificial Intelligence and Computer Assisted Instruction. CITE Report No. 4.
ERIC Educational Resources Information Center
Elsom-Cook, Mark
The purpose of the paper is to outline some of the major ways in which artificial intelligence research and techniques can affect usage of computers in an educational environment. The role of artificial intelligence is defined, and the difference between Computer Aided Instruction (CAI) and Intelligent Computer Aided Instruction (ICAI) is…
User's guide to the Residual Gas Analyzer (RGA)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Artman, S.A.
1988-08-04
The Residual Gas Analyzer (RGA), a Model 100C UTI quadrupole mass spectrometer, measures the concentrations of selected masses in the Fusion Energy Division's (FED) Advanced Toroidal Facility (ATF). The RGA software is a VAX FORTRAN computer program which controls the experimental apparatus, records the raw data, performs data reduction, and plots the data. The RGA program allows data to be collected from an RGA on ATF or from either of two RGAs in the laboratory. In the laboratory, the RGA diagnostic plays an important role in outgassing studied on various candidate materials for fusion experiments. One such material, graphite, ismore » being used more often in fusion experiments due to its ability to withstand high power loads. One of the functions of the RGA diagnostic is aid in the determination of the best grade of graphite to be used in these experiments and to study the procedures used to condition it. A procedure of particular interest involves baking the graphite sample in order to remove impurities that may be present in it. These impurities can be studied while in the ATF plasma or while being baked and outgassed in the laboratory. The Residual Gas Analyzer is a quadrupole mass spectrometer capable of scanning masses ranging in size from 1 atomic mass unit (amu) to 300 amu while under computer control. The procedure for collecting data for a particular mass is outlined.« less
Quantitative analysis of breast cancer diagnosis using a probabilistic modelling approach.
Liu, Shuo; Zeng, Jinshu; Gong, Huizhou; Yang, Hongqin; Zhai, Jia; Cao, Yi; Liu, Junxiu; Luo, Yuling; Li, Yuhua; Maguire, Liam; Ding, Xuemei
2018-01-01
Breast cancer is the most prevalent cancer in women in most countries of the world. Many computer-aided diagnostic methods have been proposed, but there are few studies on quantitative discovery of probabilistic dependencies among breast cancer data features and identification of the contribution of each feature to breast cancer diagnosis. This study aims to fill this void by utilizing a Bayesian network (BN) modelling approach. A K2 learning algorithm and statistical computation methods are used to construct BN structure and assess the obtained BN model. The data used in this study were collected from a clinical ultrasound dataset derived from a Chinese local hospital and a fine-needle aspiration cytology (FNAC) dataset from UCI machine learning repository. Our study suggested that, in terms of ultrasound data, cell shape is the most significant feature for breast cancer diagnosis, and the resistance index presents a strong probabilistic dependency on blood signals. With respect to FNAC data, bare nuclei are the most important discriminating feature of malignant and benign breast tumours, and uniformity of both cell size and cell shape are tightly interdependent. The BN modelling approach can support clinicians in making diagnostic decisions based on the significant features identified by the model, especially when some other features are missing for specific patients. The approach is also applicable to other healthcare data analytics and data modelling for disease diagnosis. Copyright © 2017 Elsevier Ltd. All rights reserved.
Electronic Circuit Analysis Language (ECAL)
NASA Astrophysics Data System (ADS)
Chenghang, C.
1983-03-01
The computer aided design technique is an important development in computer applications and it is an important component of computer science. The special language for electronic circuit analysis is the foundation of computer aided design or computer aided circuit analysis (abbreviated as CACD and CACA) of simulated circuits. Electronic circuit analysis language (ECAL) is a comparatively simple and easy to use circuit analysis special language which uses the FORTRAN language to carry out the explanatory executions. It is capable of conducting dc analysis, ac analysis, and transient analysis of a circuit. Futhermore, the results of the dc analysis can be used directly as the initial conditions for the ac and transient analyses.
Leonardi Dutra, Kamile; Haas, Letícia; Porporatti, André Luís; Flores-Mir, Carlos; Nascimento Santos, Juliana; Mezzomo, Luis André; Corrêa, Márcio; De Luca Canto, Graziela
2016-03-01
Endodontic diagnosis depends on accurate radiographic examination. Assessment of the location and extent of apical periodontitis (AP) can influence treatment planning and subsequent treatment outcomes. Therefore, this systematic review and meta-analysis assessed the diagnostic accuracy of conventional radiography and cone-beam computed tomographic (CBCT) imaging on the discrimination of AP from no lesion. Eight electronic databases with no language or time limitations were searched. Articles in which the primary objective was to evaluate the accuracy (sensitivity and specificity) of any type of radiographic technique to assess AP in humans were selected. The gold standard was the histologic examination for actual AP (in vivo) or in situ visualization of bone defects for induced artificial AP (in vitro). Accuracy measurements described in the studies were transformed to construct receiver operating characteristic curves and forest plots with the aid of Review Manager v.5.2 (The Nordic Cochrane Centre, Copenhagen, Denmark) and MetaDisc v.1.4. software (Unit of Clinical Biostatistics Team of the Ramón y Cajal Hospital, Madrid, Spain). The methodology of the selected studies was evaluated using the Quality Assessment Tool for Diagnostic Accuracy Studies-2. Only 9 studies met the inclusion criteria and were subjected to a qualitative analysis. A meta-analysis was conducted on 6 of these articles. All of these articles studied artificial AP with induced bone defects. The accuracy values (area under the curve) were 0.96 for CBCT imaging, 0.73 for conventional periapical radiography, and 0.72 for digital periapical radiography. No evidence was found for panoramic radiography. Periapical radiographs (digital and conventional) reported good diagnostic accuracy on the discrimination of artificial AP from no lesions, whereas CBCT imaging showed excellent accuracy values. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
WINCADRE INORGANIC (WINDOWS COMPUTER-AIDED DATA REVIEW AND EVALUATION)
WinCADRE (Computer-Aided Data Review and Evaluation) is a Windows -based program designed for computer-assisted data validation. WinCADRE is a powerful tool which significantly decreases data validation turnaround time. The electronic-data-deliverable format has been designed in...
CANARY Risk Management of Adenocarcinoma: The Future of Imaging?
Foley, Finbar; Rajagopalan, Srinivasan; Raghunath, Sushravya M; Boland, Jennifer M; Karwoski, Ronald A.; Maldonado, Fabien; Bartholmai, Brian J; Peikert, Tobias
2016-01-01
Increased clinical utilization of chest high resolution computed tomography results in increased identification of lung adenocarcinomas and persistent sub-solid opacities. However, these lesions range from very indolent to extremely aggressive tumors. Clinically relevant diagnostic tools to non-invasively risk stratify and guide individualized management of these lesions are lacking. Research efforts investigating semi-quantitative measures to decrease inter- and intra-rater variability are emerging, and in some cases steps have been taken to automate this process. However, many such methods currently are still sub-optimal, require validation and are not yet clinically applicable. The Computer-Aided Nodule Assessment and Risk Yield (CANARY) software application represents a validated tool for the automated, quantitative, non-invasive tool for risk stratification of adenocarcinoma lung nodules. CANARY correlates well with consensus histology and post-surgical patient outcomes and therefore may help to guide individualized patient management e.g. in identification of nodules amenable to radiological surveillance, or in need of adjunctive therapy. PMID:27568149
Current perspectives of CASA applications in diverse mammalian spermatozoa.
van der Horst, Gerhard; Maree, Liana; du Plessis, Stefan S
2018-03-26
Since the advent of computer-aided sperm analysis (CASA) some four decades ago, advances in computer technology and software algorithms have helped establish it as a research and diagnostic instrument for the analysis of spermatozoa. Despite mammalian spermatozoa being the most diverse cell type known, CASA is a great tool that has the capacity to provide rapid, reliable and objective quantitative assessment of sperm quality. This paper provides contemporary research findings illustrating the scientific and commercial applications of CASA and its ability to evaluate diverse mammalian spermatozoa (human, primates, rodents, domestic mammals, wildlife species) at both structural and functional levels. The potential of CASA to quantitatively measure essential aspects related to sperm subpopulations, hyperactivation, morphology and morphometry is also demonstrated. Furthermore, applications of CASA are provided for improved mammalian sperm quality assessment, evaluation of sperm functionality and the effect of different chemical substances or pathologies on sperm fertilising ability. It is clear that CASA has evolved significantly and is currently superior to many manual techniques in the research and clinical setting.
Tzou, Chieh-Han John; Pona, Igor; Placheta, Eva; Hold, Alina; Michaelidou, Maria; Artner, Nicole; Kropatsch, Walter; Gerber, Hans; Frey, Manfred
2012-08-01
Since the implementation of the computer-aided system for assessing facial palsy in 1999 by Frey et al (Plast Reconstr Surg. 1999;104:2032-2039), no similar system that can make an objective, three-dimensional, quantitative analysis of facial movements has been marketed. This system has been in routine use since its launch, and it has proven to be reliable, clinically applicable, and therapeutically accurate. With the cooperation of international partners, more than 200 patients were analyzed. Recent developments in computer vision--mostly in the area of generative face models, applying active--appearance models (and extensions), optical flow, and video-tracking-have been successfully incorporated to automate the prototype system. Further market-ready development and a business partner will be needed to enable the production of this system to enhance clinical methodology in diagnostic and prognostic accuracy as a personalized therapy concept, leading to better results and higher quality of life for patients with impaired facial function.
Diagnostic Flow Cytometry and the AIDS Pandemic.
Clift, Ian C
2015-01-01
The onset of the AIDS pandemic in the early 1980s coincided with the convergence of technologies now collectively known as flow cytometry (FCM). Major advances in FCM led significantly toward our understanding of the pathogenicity of the disease, which in turn led to wider adoption of the technology, including using it effectively in a variety of diagnostics. CD4+ T lymphocyte population counts, along with human immunodeficiency virus (HIV) viral load, remain the gold standard in diagnosis and continue to play a major role in the monitoring of advanced retroviral therapies. Arguably, the spread of AIDS (acquired immunodeficiency syndrome), the HIV virus, and the toll of the virus on humanity have been considerably altered by the concurrent development of FCM, the details of which are presented herein. Copyright© by the American Society for Clinical Pathology (ASCP).
Lin, Chun-Li; Chang, Yen-Hsiang; Hsieh, Shih-Kai; Chang, Wen-Jen
2013-03-01
This study evaluated the risk of failure for an endodontically treated premolar with different crack depths, which was shearing toward the pulp chamber and was restored by using 3 different computer-aided design/computer-aided manufacturing ceramic restoration configurations. Three 3-dimensional finite element models designed with computer-aided design/computer-aided manufacturing ceramic onlay, endocrown, and conventional crown restorations were constructed to perform simulations. The Weibull function was incorporated with finite element analysis to calculate the long-term failure probability relative to different load conditions. The results indicated that the stress values on the enamel, dentin, and luting cement for endocrown restorations exhibited the lowest values relative to the other 2 restoration methods. Weibull analysis revealed that the overall failure probabilities in a shallow cracked premolar were 27%, 2%, and 1% for the onlay, endocrown, and conventional crown restorations, respectively, in the normal occlusal condition. The corresponding values were 70%, 10%, and 2% for the depth cracked premolar. This numeric investigation suggests that the endocrown provides sufficient fracture resistance only in a shallow cracked premolar with endodontic treatment. The conventional crown treatment can immobilize the premolar for different cracked depths with lower failure risk. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Bertoldi, Eduardo G; Stella, Steffan F; Rohde, Luis E; Polanczyk, Carisi A
2016-05-01
Several tests exist for diagnosing coronary artery disease, with varying accuracy and cost. We sought to provide cost-effectiveness information to aid physicians and decision-makers in selecting the most appropriate testing strategy. We used the state-transitions (Markov) model from the Brazilian public health system perspective with a lifetime horizon. Diagnostic strategies were based on exercise electrocardiography (Ex-ECG), stress echocardiography (ECHO), single-photon emission computed tomography (SPECT), computed tomography coronary angiography (CTA), or stress cardiac magnetic resonance imaging (C-MRI) as the initial test. Systematic review provided input data for test accuracy and long-term prognosis. Cost data were derived from the Brazilian public health system. Diagnostic test strategy had a small but measurable impact in quality-adjusted life-years gained. Switching from Ex-ECG to CTA-based strategies improved outcomes at an incremental cost-effectiveness ratio of 3100 international dollars per quality-adjusted life-year. ECHO-based strategies resulted in cost and effectiveness almost identical to CTA, and SPECT-based strategies were dominated because of their much higher cost. Strategies based on stress C-MRI were most effective, but the incremental cost-effectiveness ratio vs CTA was higher than the proposed willingness-to-pay threshold. Invasive strategies were dominant in the high pretest probability setting. Sensitivity analysis showed that results were sensitive to costs of CTA, ECHO, and C-MRI. Coronary CT is cost-effective for the diagnosis of coronary artery disease and should be included in the Brazilian public health system. Stress ECHO has a similar performance and is an acceptable alternative for most patients, but invasive strategies should be reserved for patients at high risk. © 2016 Wiley Periodicals, Inc.
Shiraishi, Junji; Pesce, Lorenzo L.; Metz, Charles E.; Doi, Kunio
2009-01-01
Purpose: To provide a broad perspective concerning the recent use of receiver operating characteristic (ROC) analysis in medical imaging by reviewing ROC studies published in Radiology between 1997 and 2006 for experimental design, imaging modality, medical condition, and ROC paradigm. Materials and Methods: Two hundred ninety-five studies were obtained by conducting a literature search with PubMed with two criteria: publication in Radiology between 1997 and 2006 and occurrence of the phrase “receiver operating characteristic.” Studies returned by the query that were not diagnostic imaging procedure performance evaluations were excluded. Characteristics of the remaining studies were tabulated. Results: Two hundred thirty-three (79.0%) of the 295 studies reported findings based on observers' diagnostic judgments or objective measurements. Forty-three (14.6%) did not include human observers, with most of these reporting an evaluation of a computer-aided diagnosis system or functional data obtained with computed tomography (CT) or magnetic resonance (MR) imaging. The remaining 19 (6.4%) studies were classified as reviews or meta-analyses and were excluded from our subsequent analysis. Among the various imaging modalities, MR imaging (46.0%) and CT (25.7%) were investigated most frequently. Approximately 60% (144 of 233) of ROC studies with human observers published in Radiology included three or fewer observers. Conclusion: ROC analysis is widely used in radiologic research, confirming its fundamental role in assessing diagnostic performance. However, the ROC studies reported in Radiology were not always adequate to support clear and clinically relevant conclusions. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533081632/-/DC1 PMID:19864510
Advances in computer-aided well-test interpretation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Horne, R.N.
1994-07-01
Despite the feeling expressed several times over the past 40 years that well-test analysis had reached it peak development, an examination of recent advances shows continuous expansion in capability, with future improvement likely. The expansion in interpretation capability over the past decade arose mainly from the development of computer-aided techniques, which, although introduced 20 years ago, have come into use only recently. The broad application of computer-aided interpretation originated with the improvement of the methodologies and continued with the expansion in computer access and capability that accompanied the explosive development of the microcomputer industry. This paper focuses on the differentmore » pieces of the methodology that combine to constitute a computer-aided interpretation and attempts to compare some of the approaches currently used. Future directions of the approach are also discussed. The separate areas discussed are deconvolution, pressure derivatives, model recognition, nonlinear regression, and confidence intervals.« less
Features of Computer-Based Decision Aids: Systematic Review, Thematic Synthesis, and Meta-Analyses
Krömker, Dörthe; Meguerditchian, Ari N; Tamblyn, Robyn
2016-01-01
Background Patient information and education, such as decision aids, are gradually moving toward online, computer-based environments. Considerable research has been conducted to guide content and presentation of decision aids. However, given the relatively new shift to computer-based support, little attention has been given to how multimedia and interactivity can improve upon paper-based decision aids. Objective The first objective of this review was to summarize published literature into a proposed classification of features that have been integrated into computer-based decision aids. Building on this classification, the second objective was to assess whether integration of specific features was associated with higher-quality decision making. Methods Relevant studies were located by searching MEDLINE, Embase, CINAHL, and CENTRAL databases. The review identified studies that evaluated computer-based decision aids for adults faced with preference-sensitive medical decisions and reported quality of decision-making outcomes. A thematic synthesis was conducted to develop the classification of features. Subsequently, meta-analyses were conducted based on standardized mean differences (SMD) from randomized controlled trials (RCTs) that reported knowledge or decisional conflict. Further subgroup analyses compared pooled SMDs for decision aids that incorporated a specific feature to other computer-based decision aids that did not incorporate the feature, to assess whether specific features improved quality of decision making. Results Of 3541 unique publications, 58 studies met the target criteria and were included in the thematic synthesis. The synthesis identified six features: content control, tailoring, patient narratives, explicit values clarification, feedback, and social support. A subset of 26 RCTs from the thematic synthesis was used to conduct the meta-analyses. As expected, computer-based decision aids performed better than usual care or alternative aids; however, some features performed better than others. Integration of content control improved quality of decision making (SMD 0.59 vs 0.23 for knowledge; SMD 0.39 vs 0.29 for decisional conflict). In contrast, tailoring reduced quality of decision making (SMD 0.40 vs 0.71 for knowledge; SMD 0.25 vs 0.52 for decisional conflict). Similarly, patient narratives also reduced quality of decision making (SMD 0.43 vs 0.65 for knowledge; SMD 0.17 vs 0.46 for decisional conflict). Results were varied for different types of explicit values clarification, feedback, and social support. Conclusions Integration of media rich or interactive features into computer-based decision aids can improve quality of preference-sensitive decision making. However, this is an emerging field with limited evidence to guide use. The systematic review and thematic synthesis identified features that have been integrated into available computer-based decision aids, in an effort to facilitate reporting of these features and to promote integration of such features into decision aids. The meta-analyses and associated subgroup analyses provide preliminary evidence to support integration of specific features into future decision aids. Further research can focus on clarifying independent contributions of specific features through experimental designs and refining the designs of features to improve effectiveness. PMID:26813512
NASA Technical Reports Server (NTRS)
Abbott, Kathy
1990-01-01
The objective of the research in this area of fault management is to develop and implement a decision aiding concept for diagnosing faults, especially faults which are difficult for pilots to identify, and to develop methods for presenting the diagnosis information to the flight crew in a timely and comprehensible manner. The requirements for the diagnosis concept were identified by interviewing pilots, analyzing actual incident and accident cases, and examining psychology literature on how humans perform diagnosis. The diagnosis decision aiding concept developed based on those requirements takes abnormal sensor readings as input, as identified by a fault monitor. Based on these abnormal sensor readings, the diagnosis concept identifies the cause or source of the fault and all components affected by the fault. This concept was implemented for diagnosis of aircraft propulsion and hydraulic subsystems in a computer program called Draphys (Diagnostic Reasoning About Physical Systems). Draphys is unique in two important ways. First, it uses models of both functional and physical relationships in the subsystems. Using both models enables the diagnostic reasoning to identify the fault propagation as the faulted system continues to operate, and to diagnose physical damage. Draphys also reasons about behavior of the faulted system over time, to eliminate possibilities as more information becomes available, and to update the system status as more components are affected by the fault. The crew interface research is examining display issues associated with presenting diagnosis information to the flight crew. One study examined issues for presenting system status information. One lesson learned from that study was that pilots found fault situations to be more complex if they involved multiple subsystems. Another was pilots could identify the faulted systems more quickly if the system status was presented in pictorial or text format. Another study is currently under way to examine pilot mental models of the aircraft subsystems and their use in diagnosis tasks. Future research plans include piloted simulation evaluation of the diagnosis decision aiding concepts and crew interface issues. Information is given in viewgraph form.
Neuroimaging in adult penetrating brain injury: a guide for radiographers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Temple, Nikki; Donald, Cortny; Skora, Amanda
Penetrating brain injuries (PBI) are a medical emergency, often resulting in complex damage and high mortality rates. Neuroimaging is essential to evaluate the location and extent of injuries, and to manage them accordingly. Currently, a myriad of imaging modalities are included in the diagnostic workup for adult PBI, including skull radiography, computed tomography (CT), magnetic resonance imaging (MRI) and angiography, with each modality providing their own particular benefits. This literature review explores the current modalities available for investigating PBI and aims to assist in decision making for the appropriate use of diagnostic imaging when presented with an adult PBI. Basedmore » on the current literature, the authors have developed an imaging pathway for adult penetrating brain injury that functions as both a learning tool and reference guide for radiographers and other health professionals. Currently, CT is recommended as the imaging modality of choice for the initial assessment of PBI patients, while MRI is important in the sub-acute setting where it aids prognosis prediction and rehabilitation planning, Additional follow-up imaging, such as angiography, should be dependent upon clinical findings.« less
ERIC Educational Resources Information Center
Lintz, Larry M.; And Others
This study investigated the feasibility of a low cost computer-aided instruction/computer-managed instruction (CAI/CMI) system. Air Force instructors and training supervisors were surveyed to determine the potential payoffs of various CAI and CMI functions. Results indicated that a wide range of capabilities had potential for resident technical…
ERIC Educational Resources Information Center
Pollard, Jim
This report reviews software packages for Apple Macintosh and Apple II computers available to secondary schools to teach computer-aided drafting (CAD). Products for the report were gathered through reviews of CAD periodicals, computers in education periodicals, advertisements, and teacher recommendations. The first section lists the primary…
40 CFR 1033.110 - Emission diagnostics-general requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... engine operation. (d) Record and store in computer memory any diagnostic trouble codes showing a... and understand the diagnostic trouble codes stored in the onboard computer with generic tools and...
Computer Aided Drug Design: Success and Limitations.
Baig, Mohammad Hassan; Ahmad, Khurshid; Roy, Sudeep; Ashraf, Jalaluddin Mohammad; Adil, Mohd; Siddiqui, Mohammad Haris; Khan, Saif; Kamal, Mohammad Amjad; Provazník, Ivo; Choi, Inho
2016-01-01
Over the last few decades, computer-aided drug design has emerged as a powerful technique playing a crucial role in the development of new drug molecules. Structure-based drug design and ligand-based drug design are two methods commonly used in computer-aided drug design. In this article, we discuss the theory behind both methods, as well as their successful applications and limitations. To accomplish this, we reviewed structure based and ligand based virtual screening processes. Molecular dynamics simulation, which has become one of the most influential tool for prediction of the conformation of small molecules and changes in their conformation within the biological target, has also been taken into account. Finally, we discuss the principles and concepts of molecular docking, pharmacophores and other methods used in computer-aided drug design.
Jo, Chanwoo; Bae, Doohwan; Choi, Byungho; Kim, Jihun
2017-05-01
Supernumerary teeth need to be removed because they can cause various complications. Caution is needed because their removal can cause damage to permanent teeth or tooth germs in the local vicinity. Surgical guides have recently been used in maxillofacial surgery. Because surgical guides are designed through preoperative analysis by computer-aided design software and fabricated using a 3-dimensional printer applying computer-aided manufacturing technology, they increase the accuracy and predictability of surgery. This report describes 2 cases of removal of a mesiodens-1 from a child and 1 from an adolescent-using a surgical guide; these would have been difficult to remove with conventional surgical methods. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Current and emerging technologies in melanoma diagnosis: the state of the art
Psaty, Estee L.; Halpern, Allan C.
2017-01-01
Relative to other specialties, dermatologists have been slow to adopt advanced technologic diagnostic aids. After all, most skin disease can be diagnosed by simple visual inspection, and the skin is readily accessible for a diagnostic biopsy. Diagnostic aids such as total body photography and dermoscopy improve the clinician's ability to diagnose melanoma beyond unaided visual inspection, however, and are now considered mainstream methods for early detection. Emerging technologies such as in vivo reflectance confocal microscopy are currently being investigated to determine their utility for noninvasive diagnosis of melanoma. This review summarizes the currently available cutaneous imaging devices and new frontiers in noninvasive diagnosis of skin disease. We anticipate that multimodal systems that combine different imaging technologies will further improve our ability to detect, at the bedside, melanoma at an earlier stage. PMID:19095152
The mental health impact of AIDS-related mortality in South Africa: a national study
Myer, L; Seedat, S; Stein, D J; Moomal, H; Williams, D R
2011-01-01
Background Few data exist on how the HIV/AIDS epidemic may influence population mental health. The associations were examined between knowing someone who died of HIV/AIDS and common mental disorders among South African adults. Methods Between 2002 and 2004, a nationally representative sample of 4351 adults were interviewed about personally knowing someone who died of HIV/AIDS, and the World Health Organization Composite International Diagnostic Interview was used to generate psychiatric diagnoses for depression, anxiety and substance abuse disorders during the preceding 12 months based on the Diagnostic and Statistical Manual, 4th edition (DSM-IV). Results Overall, 42.2% of the sample knew someone who died of HIV/AIDS, and 16.5% met the criteria for at least one DSM-IV diagnosis. Individuals who knew someone who died of HIV/AIDS were significantly more likely to have any DSM-IV defined disorder, including any depressive, anxiety or substance-related disorder (p<0.001 for all associations). In multivariate models adjusted for participant demographic characteristics, life events and socioeconomic status, individual disorders significantly associated with knowing someone who died of HIV/AIDS included generalised anxiety disorder, social phobia and alcohol/drug dependence or abuse. Based on these results, it is estimated that up to 15% of 12-month DSM-IV disorders in the South African adult population may be related to knowing someone who died of HIV/AIDS. Conclusion These novel data suggest that AIDS-related mortality may contribute substantially to the burden of mental disorders in settings of high HIV prevalence. While this finding requires further investigation, these data suggest the need to strengthen mental health services in communities where HIV/AIDS is prevalent. PMID:19074926
21 CFR 866.5180 - Fecal calprotectin immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... immunological test system is an in vitro diagnostic device that consists of reagents used to quantitatively measure, by immunochemical techniques, fecal calprotectin in human stool specimens. The device is intended forin vitro diagnostic use as an aid in the diagnosis of inflammatory bowel diseases (IBD), specifically...
40 CFR 86.1806-01 - On-board diagnostics.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... The emission control diagnostic system shall record and store in computer memory diagnostic trouble... or system, “freeze frame” engine conditions present at the time shall be stored in computer memory... equipped with an onboard diagnostic (OBD) system capable of monitoring, for each vehicle's useful life, all...
40 CFR 86.1806-01 - On-board diagnostics.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... The emission control diagnostic system shall record and store in computer memory diagnostic trouble... or system, “freeze frame” engine conditions present at the time shall be stored in computer memory... equipped with an onboard diagnostic (OBD) system capable of monitoring, for each vehicle's useful life, all...
40 CFR 86.1806-01 - On-board diagnostics.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... The emission control diagnostic system shall record and store in computer memory diagnostic trouble... or system, “freeze frame” engine conditions present at the time shall be stored in computer memory... equipped with an onboard diagnostic (OBD) system capable of monitoring, for each vehicle's useful life, all...
Web-Based Learning in the Computer-Aided Design Curriculum.
ERIC Educational Resources Information Center
Sung, Wen-Tsai; Ou, S. C.
2002-01-01
Applies principles of constructivism and virtual reality (VR) to computer-aided design (CAD) curriculum, particularly engineering, by integrating network, VR and CAD technologies into a Web-based learning environment that expands traditional two-dimensional computer graphics into a three-dimensional real-time simulation that enhances user…
Integrated Computer-Aided Drafting Instruction (ICADI).
ERIC Educational Resources Information Center
Chen, C. Y.; McCampbell, David H.
Until recently, computer-aided drafting and design (CAD) systems were almost exclusively operated on mainframes or minicomputers and their cost prohibited many schools from offering CAD instruction. Today, many powerful personal computers are capable of performing the high-speed calculation and analysis required by the CAD application; however,…
A Computer-Aided Diagnosis System for Breast Cancer Combining Digital Mammography and Genomics
2006-05-01
Huang, "Breast cancer diagnosis using self-organizing map for sonography." Ultrasound Med. Biol. 26, 405 (2000). 20 K. Horsch, M.L. Giger, L.A. Venta ...L.A. Venta , "Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography." Acad Radiol 11, 272 (2004). 22 W. Chen...418. 27. Horsch K, Giger ML, Vyborny CJ, Venta LA. Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography
Computer-aided design of the RF-cavity for a high-power S-band klystron
NASA Astrophysics Data System (ADS)
Kant, D.; Bandyopadhyay, A. K.; Pal, D.; Meena, R.; Nangru, S. C.; Joshi, L. M.
2012-08-01
This article describes the computer-aided design of the RF-cavity for a S-band klystron operating at 2856 MHz. State-of-the-art electromagnetic simulation tools SUPERFISH, CST Microwave studio, HFSS and MAGIC have been used for cavity design. After finalising the geometrical details of the cavity through simulation, it has been fabricated and characterised through cold testing. Detailed results of the computer-aided simulation and cold measurements are presented in this article.
Computer aided design of monolithic microwave and millimeter wave integrated circuits and subsystems
NASA Astrophysics Data System (ADS)
Ku, Walter H.; Gang, Guan-Wan; He, J. Q.; Ichitsubo, I.
1988-05-01
This final technical report presents results on the computer aided design of monolithic microwave and millimeter wave integrated circuits and subsystems. New results include analytical and computer aided device models of GaAs MESFETs and HEMTs or MODFETs, new synthesis techniques for monolithic feedback and distributed amplifiers and a new nonlinear CAD program for MIMIC called CADNON. This program incorporates the new MESFET and HEMT model and has been successfully applied to the design of monolithic millimeter-wave mixers.
An Interactive Computer Aided Design and Analysis Package.
1986-03-01
Al-A167 114 AN INTERACTIVE COMPUTER AIDED DESIGN MUD ANAILYSIS 1/ PACKAGE(U) NAVAL POSTGRADUATE SCHOOL NONTEREY CA T L EUALD "AR 86 UNCLSSIFIED F... SCHOOL Monterey, California DTIC .LECTE MAYOS THESIS AN INTERACTIVE COMPUTER AIDED DESIGN AND ANALYSIS PACKAGE by Terrence L. Ewald March 1986 jThesis...ORGANIZATION Naval Postgraduate School (if dAp90h81111) Naval Postgraduate School . 62A 6C. ADDRESS (0ty. State, and ZIP Code) 7b. ADDRESS (City State. and
ERIC Educational Resources Information Center
Proctor, Tony
1988-01-01
Explores the conceptual components of a computer program designed to enhance creative thinking and reviews software that aims to stimulate creative thinking. Discusses BRAIN and ORACLE, programs intended to aid in creative problem solving. (JOW)
Prerequisites for Computer-Aided Cognitive Rehabilitation.
ERIC Educational Resources Information Center
Legrand, Colette
1989-01-01
This paper describes computer-aided cognitive rehabilitation for mentally deficient persons. It lists motor, cognitive, emotional, and educational prerequisites to such rehabilitation and states advantages and disadvantages in using the prerequisites. (JDD)
ERIC Educational Resources Information Center
Attinasi, Louis C., Jr.; Fenske, Robert H.
1988-01-01
Two computer models used at Arizona State University recognize the tendency of students from low-income and minority backgrounds to apply for assistance late in the funding cycle. They permit administrators to project the amount of aid needed by such students. The Financial Aid Computerized Tracking System is described. (Author/MLW)
Malamud, Daniel; Rodriguez-Chavez, Isaac R.
2010-01-01
Synopsis Salivary diagnostics is a dynamic and emerging field utilizing nanotechnology and molecular diagnostics to aid in the diagnosis of oral and systemic diseases. Here, we critically review the latest advances using oral biomarkers for disease detection. The use of oral fluids is broadening perspectives in clinical diagnosis, disease monitoring and decision making for patient care. Important elements determining the future possibilities and challenges in this field are also discussed. PMID:21094724
Incorporation of CAD/CAM Restoration Into Navy Dentistry
2017-09-26
CAD/CAM Computer-aided design /Computer-assisted manufacturing CDT Common Dental Terminology DENCAS Dental Common Access System DTF Dental...to reduce avoidable dental emergencies for deployed sailors and marines. Dental Computer-aided design /Computer-assisted manufacturing (CAD/CAM...report will review and evaluate the placement rate by Navy dentists of digitally fabricated in-office ceramic restorations compared to traditional direct
ERIC Educational Resources Information Center
Aksakalli, Ayhan; Turgut, Umit; Salar, Riza
2016-01-01
This research aims to investigate the ways in which pre-service physics teachers interact with computers, which, as an indispensable means of today's technology, are of major value in education and training, and to identify any misconceptions said teachers may have about computer-aided instruction. As part of the study, computer-based physics…
Conrad, K; Andrade, L E C; Chan, E K L; Mahler, M; Meroni, P L; Pruijn, G J M; Steiner, G; Shoenfeld, Y
2016-07-01
Testing for autoantibodies (AABs) is becoming more and more relevant, not only for diagnosing autoimmune diseases (AIDs) but also for the differentiation of defined AID subtypes with different clinical manifestations, course and prognosis as well as the very early diagnosis for adequate management in the context of personalized medicine. A major challenge to improve diagnostic accuracy is to harmonize or even standardize AAB analyses. This review presents the results of the 12th Dresden Symposium on Autoantibodies that focused on several aspects of improving autoimmune diagnostics. Topics that are addressed include the International Consensus on ANA Patterns (ICAP) and the International Autoantibody Standardization (IAS) initiatives, the optimization of diagnostic algorithms, the description and evaluation of novel disease-specific AABs as well as the development and introduction of novel assays into routine diagnostics. This review also highlights important developments of recent years, most notably the improvement in diagnosing and predicting the course of rheumatoid arthritis, systemic sclerosis, idiopathic inflammatory myopathies, and of autoimmune neurological, gastrointestinal and liver diseases; the potential diagnostic role of anti-DFS70 antibodies and tumor-associated AABs. Furthermore, some hot topics in autoimmunity regarding disease pathogenesis and management are described. © The Author(s) 2016.
Student Performance in Computer-Assisted Instruction in Programming.
ERIC Educational Resources Information Center
Friend, Jamesine E.; And Others
A computer-assisted instructional system to teach college students the computer language, AID (Algebraic Interpretive Dialogue), two control programs, and data collected by the two control programs are described. It was found that although first response errors were often those of AID syntax, such errors were easily corrected. Secondly, while…
Cooperation Support in Computer-Aided Authoring and Learning.
ERIC Educational Resources Information Center
Muhlhauser, Max; Rudebusch, Tom
This paper discusses the use of Computer Supported Cooperative Work (CSCW) techniques for computer-aided learning (CAL); the work was started in the context of project Nestor, a joint effort of German universities about cooperative multimedia authoring/learning environments. There are four major categories of cooperation for CAL: author/author,…
Computer-Assisted Instruction: One Aid for Teachers of Reading.
ERIC Educational Resources Information Center
Rauch, Margaret; Samojeden, Elizabeth
Computer assisted instruction (CAI), an instructional system with direct interaction between the student and the computer, can be a valuable aid for presenting new concepts, for reinforcing of selective skills, and for individualizing instruction. The advantages CAI provides include self-paced learning, more efficient allocation of classroom time,…
Gebremariam, Etsay Hailu; Nasir, Zebiba
2017-01-01
Background. Human Immune Deficiency Virus (HIV/AIDS) continues to be an underrecognized risk for suicidal ideation, suicidal attempt, and completion of suicide. Suicidal ideation and attempt in HIV/AIDS is not only a predictor of future attempted suicide and completed suicide. Methods. An institution based cross-sectional study was conducted among HIV-positive patients attending HIV care at Zewditu Memorial Hospital. Systematic random sampling technique was used to recruit 423 participants from April to May 2014. Composite International Diagnostic Interview was used to collect data. Multivariable logistic regression was computed to assess factors associated with suicidal ideation and attempt. Result. Suicidal ideation and suicidal attempt were found to be 22.5% and 13.9%, respectively. WHO clinical stage of HIV, not being on HAART, depression, family history of suicidal attempt, and perceived stigma were associated with suicidal ideation. WHO clinical stage, being female, not being on HAART, use of substance, and depression were associated with suicidal attempt. Conclusion. Early diagnosis and treatment of opportunistic infections, depression, and early initiation of ART need to be encouraged in HIV-positive adults. Furthermore, counseling on substance use and its consequences and early identification of HIV-positive people with family history of suicidal ideation have to be considered. PMID:28491869
Computer-aided design of high-frequency transistor amplifiers.
NASA Technical Reports Server (NTRS)
Hsieh, C.-C.; Chan, S.-P.
1972-01-01
A systematic step-by-step computer-aided procedure for designing high-frequency transistor amplifiers is described. The technique makes it possible to determine the optimum source impedance which gives a minimum noise figure.
Three-dimensional surgical simulation.
Cevidanes, Lucia H C; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael
2010-09-01
In this article, we discuss the development of methods for computer-aided jaw surgery, which allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3-dimensional surface models from cone-beam computed tomography, dynamic cephalometry, semiautomatic mirroring, interactive cutting of bone, and bony segment repositioning. A virtual setup can be used to manufacture positioning splints for intraoperative guidance. The system provides further intraoperative assistance with a computer display showing jaw positions and 3-dimensional positioning guides updated in real time during the surgical procedure. The computer-aided surgery system aids in dealing with complex cases with benefits for the patient, with surgical practice, and for orthodontic finishing. Advanced software tools for diagnosis and treatment planning allow preparation of detailed operative plans, osteotomy repositioning, bone reconstructions, surgical resident training, and assessing the difficulties of the surgical procedures before the surgery. Computer-aided surgery can make the elaboration of the surgical plan a more flexible process, increase the level of detail and accuracy of the plan, yield higher operative precision and control, and enhance documentation of cases. 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Space Spurred Computer Graphics
NASA Technical Reports Server (NTRS)
1983-01-01
Dicomed Corporation was asked by NASA in the early 1970s to develop processing capabilities for recording images sent from Mars by Viking spacecraft. The company produced a film recorder which increased the intensity levels and the capability for color recording. This development led to a strong technology base resulting in sophisticated computer graphics equipment. Dicomed systems are used to record CAD (computer aided design) and CAM (computer aided manufacturing) equipment, to update maps and produce computer generated animation.
Ye, Hongqiang; Li, Xinxin; Wang, Guanbo; Kang, Jing; Liu, Yushu; Sun, Yuchun; Zhou, Yongsheng
2018-02-15
To investigate a computer-aided design/computer-aided manufacturing (CAD/CAM) process for producing one-piece removable partial dentures (RPDs) and to evaluate their fits in vitro. A total of 15 one-piece RPDs were designed using dental CAD and reverse engineering software and then fabricated with polyetheretherketone (PEEK) using CAM. The gaps between RPDs and casts were measured and compared with traditional cast framework RPDs. Gaps were lower for one-piece PEEK RPDs compared to traditional RPDs. One-piece RPDs can be manufactured by CAD/CAM, and their fits were better than those of traditional RPDs.
Stein, Mark A; Snyder, Steven M; Rugino, Thomas A; Hornig, Mady
2016-06-01
Neuropsychiatric EEG-Based ADHD Assessment Aid (NEBA) is an EEG-based device designed to aid in the diagnostic process for ADHD by identifying individuals less likely to have ADHD by virtue of a lower theta/beta ratio. In using NEBA as an example, the Arns et al. commentary misstates the purpose of NEBA, which is to widen the differential rather than to make the diagnosis. Arns et al. caution about missing an ADHD diagnosis, but fail to mention the impact of overdiagnosis. If we are to advance our knowledge of the etiology and pathophysiology of ADHD, as well as develop tailored treatments and ultimately improve outcomes for ADHD, then biomarkers and objective assessment aids such as NEBA are needed to improve and refine diagnostic accuracy beyond symptom description and clinical history. © 2016 The Authors. Journal of Child Psychology and Psychiatry published by John Wiley & Sons Ltd on behalf of Association for Child and Adolescent Mental Health.
Effect of Computer-Presented Organizational/Memory Aids on Problem Solving Behavior.
ERIC Educational Resources Information Center
Steinberg, Esther R.; And Others
This research studied the effects of computer-presented organizational/memory aids on problem solving behavior. The aids were either matrix or verbal charts shown on the display screen next to the problem. The 104 college student subjects were randomly assigned to one of the four conditions: type of chart (matrix or verbal chart) and use of charts…
ERIC Educational Resources Information Center
Schulz, Russel E.; And Others
This Programming Design Guide (PDG) was developed to permit the offline Job Aid for Selecting Instructional Setting, which is one of 13 job aids presently available for use with the Instructional Systems Development (ISD) model, to be available in an inquiry-type, online version. It is intended to provide computer programmers with all of the…
Teaching Advance Care Planning to Medical Students with a Computer-Based Decision Aid
Levi, Benjamin H.
2013-01-01
Discussing end-of-life decisions with cancer patients is a crucial skill for physicians. This article reports findings from a pilot study evaluating the effectiveness of a computer-based decision aid for teaching medical students about advance care planning. Second-year medical students at a single medical school were randomized to use a standard advance directive or a computer-based decision aid to help patients with advance care planning. Students' knowledge, skills, and satisfaction were measured by self-report; their performance was rated by patients. 121/133 (91%) of students participated. The Decision-Aid Group (n=60) outperformed the Standard Group (n=61) in terms of students´ knowledge (p<0.01), confidence in helping patients with advance care planning (p<0.01), knowledge of what matters to patients (p=0.05), and satisfaction with their learning experience (p<0.01). Likewise, patients in the Decision Aid Group were more satisfied with the advance care planning method (p<0.01) and with several aspects of student performance. Use of a computer-based decision aid may be an effective way to teach medical students how to discuss advance care planning with cancer patients. PMID:20632222
Evaluation of direct and indirect additive manufacture of maxillofacial prostheses.
Eggbeer, Dominic; Bibb, Richard; Evans, Peter; Ji, Lu
2012-09-01
The efficacy of computer-aided technologies in the design and manufacture of maxillofacial prostheses has not been fully proven. This paper presents research into the evaluation of direct and indirect additive manufacture of a maxillofacial prosthesis against conventional laboratory-based techniques. An implant/magnet-retained nasal prosthesis case from a UK maxillofacial unit was selected as a case study. A benchmark prosthesis was fabricated using conventional laboratory-based techniques for comparison against additive manufactured prostheses. For the computer-aided workflow, photogrammetry, computer-aided design and additive manufacture (AM) methods were evaluated in direct prosthesis body fabrication and indirect production using an additively manufactured mould. Qualitative analysis of position, shape, colour and edge quality was undertaken. Mechanical testing to ISO standards was also used to compare the silicone rubber used in the conventional prosthesis with the AM material. Critical evaluation has shown that utilising a computer-aided work-flow can produce a prosthesis body that is comparable to that produced using existing best practice. Technical limitations currently prevent the direct fabrication method demonstrated in this paper from being clinically viable. This research helps prosthesis providers understand the application of a computer-aided approach and guides technology developers and researchers to address the limitations identified.
Computational modelling of the impact of AIDS on business.
Matthews, Alan P
2007-07-01
An overview of computational modelling of the impact of AIDS on business in South Africa, with a detailed description of the AIDS Projection Model (APM) for companies, developed by the author, and suggestions for further work. Computational modelling of the impact of AIDS on business in South Africa requires modelling of the epidemic as a whole, and of its impact on a company. This paper gives an overview of epidemiological modelling, with an introduction to the Actuarial Society of South Africa (ASSA) model, the most widely used such model for South Africa. The APM produces projections of HIV prevalence, new infections, and AIDS mortality on a company, based on the anonymous HIV testing of company employees, and projections from the ASSA model. A smoothed statistical model of the prevalence test data is computed, and then the ASSA model projection for each category of employees is adjusted so that it matches the measured prevalence in the year of testing. FURTHER WORK: Further techniques that could be developed are microsimulation (representing individuals in the computer), scenario planning for testing strategies, and models for the business environment, such as models of entire sectors, and mapping of HIV prevalence in time and space, based on workplace and community data.
Jürgens, Tim; Clark, Nicholas R; Lecluyse, Wendy; Meddis, Ray
2016-01-01
To use a computer model of impaired hearing to explore the effects of a physiologically-inspired hearing-aid algorithm on a range of psychoacoustic measures. A computer model of a hypothetical impaired listener's hearing was constructed by adjusting parameters of a computer model of normal hearing. Absolute thresholds, estimates of compression, and frequency selectivity (summarized to a hearing profile) were assessed using this model with and without pre-processing the stimuli by a hearing-aid algorithm. The influence of different settings of the algorithm on the impaired profile was investigated. To validate the model predictions, the effect of the algorithm on hearing profiles of human impaired listeners was measured. A computer model simulating impaired hearing (total absence of basilar membrane compression) was used, and three hearing-impaired listeners participated. The hearing profiles of the model and the listeners showed substantial changes when the test stimuli were pre-processed by the hearing-aid algorithm. These changes consisted of lower absolute thresholds, steeper temporal masking curves, and sharper psychophysical tuning curves. The hearing-aid algorithm affected the impaired hearing profile of the model to approximate a normal hearing profile. Qualitatively similar results were found with the impaired listeners' hearing profiles.
Program Aids Specification Of Multiple-Block Grids
NASA Technical Reports Server (NTRS)
Sorenson, R. L.; Mccann, K. M.
1993-01-01
3DPREP computer program aids specification of multiple-block computational grids. Highly interactive graphical preprocessing program designed for use on powerful graphical scientific computer workstation. Divided into three main parts, each corresponding to principal graphical-and-alphanumerical display. Relieves user of some burden of collecting and formatting many data needed to specify blocks and grids, and prepares input data for NASA's 3DGRAPE grid-generating computer program.
What is AIDS in Guadeloupe? A descriptive and comparative study.
Elenga, Narcisse; Georger-Sow, Marie-Thérèse; Messiaen, Thierry; Lamaury, Isabelle; Favre, Isabelle; Nacher, Mathieu; Beaucaire, Gilles
2014-03-01
Since the pathogen ecology differs between Caribbean regions, specific differences in the most frequent clinical presentations of acquired immunodeficiency syndrome (AIDS) may be expected. We therefore conducted the present retrospective cohort study in order to describe the main AIDS-defining events in Guadeloupe and to compare them with those observed in Metropolitan France and in French Guiana. We discuss the local pathogen ecology, the diagnostic limitations of hospitals in overseas territories and the drivers of the epidemic.
Applications of artificial intelligence to rotorcraft
NASA Technical Reports Server (NTRS)
Abbott, Kathy H.
1987-01-01
The application of AI technology may have significant potential payoff for rotorcraft. In the near term, the status of the technology will limit its applicability to decision aids rather than total automation. The specific application areas are categorized into onboard and nonflight aids. The onboard applications include: fault monitoring, diagnosis, and reconfiguration; mission and tactics planning; situation assessment; navigation aids, especially in nap-of-the-earth flight; and adaptive man-machine interfaces. The nonflight applications include training and maintenance diagnostics.
Jiang, Jiewei; Liu, Xiyang; Zhang, Kai; Long, Erping; Wang, Liming; Li, Wangting; Liu, Lin; Wang, Shuai; Zhu, Mingmin; Cui, Jiangtao; Liu, Zhenzhen; Lin, Zhuoling; Li, Xiaoyan; Chen, Jingjing; Cao, Qianzhong; Li, Jing; Wu, Xiaohang; Wang, Dongni; Wang, Jinghui; Lin, Haotian
2017-11-21
Ocular images play an essential role in ophthalmological diagnoses. Having an imbalanced dataset is an inevitable issue in automated ocular diseases diagnosis; the scarcity of positive samples always tends to result in the misdiagnosis of severe patients during the classification task. Exploring an effective computer-aided diagnostic method to deal with imbalanced ophthalmological dataset is crucial. In this paper, we develop an effective cost-sensitive deep residual convolutional neural network (CS-ResCNN) classifier to diagnose ophthalmic diseases using retro-illumination images. First, the regions of interest (crystalline lens) are automatically identified via twice-applied Canny detection and Hough transformation. Then, the localized zones are fed into the CS-ResCNN to extract high-level features for subsequent use in automatic diagnosis. Second, the impacts of cost factors on the CS-ResCNN are further analyzed using a grid-search procedure to verify that our proposed system is robust and efficient. Qualitative analyses and quantitative experimental results demonstrate that our proposed method outperforms other conventional approaches and offers exceptional mean accuracy (92.24%), specificity (93.19%), sensitivity (89.66%) and AUC (97.11%) results. Moreover, the sensitivity of the CS-ResCNN is enhanced by over 13.6% compared to the native CNN method. Our study provides a practical strategy for addressing imbalanced ophthalmological datasets and has the potential to be applied to other medical images. The developed and deployed CS-ResCNN could serve as computer-aided diagnosis software for ophthalmologists in clinical application.
A computer-aided diagnostic system for kidney disease
Jahantigh, Farzad Firouzi; Malmir, Behnam; Avilaq, Behzad Aslani
2017-01-01
Background Disease diagnosis is complicated since patients may demonstrate similar symptoms but physician may diagnose different diseases. There are a few number of investigations aimed to create a fuzzy expert system, as a computer aided system for disease diagnosis. Methods In this research, a cross-sectional descriptive study conducted in a kidney clinic in Tehran, Iran in 2012. Medical diagnosis fuzzy rules applied, and a set of symptoms related to the set of considered diseases defined. The input case to be diagnosed defined by assigning a fuzzy value to each symptom and then three physicians asked about each suspected diseases. Then comments of those three physicians summarized for each disease. The fuzzy inference applied to obtain a decision fuzzy set for each disease, and crisp decision values attained to determine the certainty of existence for each disease. Results Results indicated that, in the diagnosis of seven cases of kidney disease by examining 21 indicators using fuzzy expert system, kidney stone disease with 63% certainty was the most probable, renal tubular was at the lowest level with 15%, and other kidney diseases were at the other levels. The most remarkable finding of this study was that results of kidney disease diagnosis (e.g., kidney stone) via fuzzy expert system were fully compatible with those of kidney physicians. Conclusion The proposed fuzzy expert system is a valid, reliable, and flexible instrument to diagnose several typical input cases. The developed system decreases the effort of initial physical checking and manual feeding of input symptoms. PMID:28392995
A computer-aided diagnostic system for kidney disease.
Jahantigh, Farzad Firouzi; Malmir, Behnam; Avilaq, Behzad Aslani
2017-03-01
Disease diagnosis is complicated since patients may demonstrate similar symptoms but physician may diagnose different diseases. There are a few number of investigations aimed to create a fuzzy expert system, as a computer aided system for disease diagnosis. In this research, a cross-sectional descriptive study conducted in a kidney clinic in Tehran, Iran in 2012. Medical diagnosis fuzzy rules applied, and a set of symptoms related to the set of considered diseases defined. The input case to be diagnosed defined by assigning a fuzzy value to each symptom and then three physicians asked about each suspected diseases. Then comments of those three physicians summarized for each disease. The fuzzy inference applied to obtain a decision fuzzy set for each disease, and crisp decision values attained to determine the certainty of existence for each disease. Results indicated that, in the diagnosis of seven cases of kidney disease by examining 21 indicators using fuzzy expert system, kidney stone disease with 63% certainty was the most probable, renal tubular was at the lowest level with 15%, and other kidney diseases were at the other levels. The most remarkable finding of this study was that results of kidney disease diagnosis (e.g., kidney stone) via fuzzy expert system were fully compatible with those of kidney physicians. The proposed fuzzy expert system is a valid, reliable, and flexible instrument to diagnose several typical input cases. The developed system decreases the effort of initial physical checking and manual feeding of input symptoms.
Trends in radiology and experimental research.
Sardanelli, Francesco
2017-01-01
European Radiology Experimental , the new journal launched by the European Society of Radiology, is placed in the context of three general and seven radiology-specific trends. After describing the impact of population aging, personalized/precision medicine, and information technology development, the article considers the following trends: the tension between subspecialties and the unity of the discipline; attention to patient safety; the challenge of reproducibility for quantitative imaging; standardized and structured reporting; search for higher levels of evidence in radiology (from diagnostic performance to patient outcome); the increasing relevance of interventional radiology; and continuous technological evolution. The new journal will publish not only studies on phantoms, cells, or animal models but also those describing development steps of imaging biomarkers or those exploring secondary end-points of large clinical trials. Moreover, consideration will be given to studies regarding: computer modelling and computer aided detection and diagnosis; contrast materials, tracers, and theranostics; advanced image analysis; optical, molecular, hybrid and fusion imaging; radiomics and radiogenomics; three-dimensional printing, information technology, image reconstruction and post-processing, big data analysis, teleradiology, clinical decision support systems; radiobiology; radioprotection; and physics in radiology. The journal aims to establish a forum for basic science, computer and information technology, radiology, and other medical subspecialties.
Thong, Patricia S P; Tandjung, Stephanus S; Movania, Muhammad Mobeen; Chiew, Wei-Ming; Olivo, Malini; Bhuvaneswari, Ramaswamy; Seah, Hock-Soon; Lin, Feng; Qian, Kemao; Soo, Khee-Chee
2012-05-01
Oral lesions are conventionally diagnosed using white light endoscopy and histopathology. This can pose a challenge because the lesions may be difficult to visualise under white light illumination. Confocal laser endomicroscopy can be used for confocal fluorescence imaging of surface and subsurface cellular and tissue structures. To move toward real-time "virtual" biopsy of oral lesions, we interfaced an embedded computing system to a confocal laser endomicroscope to achieve a prototype three-dimensional (3-D) fluorescence imaging system. A field-programmable gated array computing platform was programmed to enable synchronization of cross-sectional image grabbing and Z-depth scanning, automate the acquisition of confocal image stacks and perform volume rendering. Fluorescence imaging of the human and murine oral cavities was carried out using the fluorescent dyes fluorescein sodium and hypericin. Volume rendering of cellular and tissue structures from the oral cavity demonstrate the potential of the system for 3-D fluorescence visualization of the oral cavity in real-time. We aim toward achieving a real-time virtual biopsy technique that can complement current diagnostic techniques and aid in targeted biopsy for better clinical outcomes.
Andriole, Katherine P; Morin, Richard L; Arenson, Ronald L; Carrino, John A; Erickson, Bradley J; Horii, Steven C; Piraino, David W; Reiner, Bruce I; Seibert, J Anthony; Siegel, Eliot
2004-12-01
The Society for Computer Applications in Radiology (SCAR) Transforming the Radiological Interpretation Process (TRIP) Initiative aims to spearhead research, education, and discovery of innovative solutions to address the problem of information and image data overload. The initiative will foster interdisciplinary research on technological, environmental and human factors to better manage and exploit the massive amounts of data. TRIP will focus on the following basic objectives: improving the efficiency of interpretation of large data sets, improving the timeliness and effectiveness of communication, and decreasing medical errors. The ultimate goal of the initiative is to improve the quality and safety of patient care. Interdisciplinary research into several broad areas will be necessary to make progress in managing the ever-increasing volume of data. The six concepts involved are human perception, image processing and computer-aided detection (CAD), visualization, navigation and usability, databases and integration, and evaluation and validation of methods and performance. The result of this transformation will affect several key processes in radiology, including image interpretation; communication of imaging results; workflow and efficiency within the health care enterprise; diagnostic accuracy and a reduction in medical errors; and, ultimately, the overall quality of care.
ERIC Educational Resources Information Center
Penn-Edwards, Sorrel
2010-01-01
The qualitative research methodology of phenomenography has traditionally required a manual sorting and analysis of interview data. In this paper I explore a potential means of streamlining this procedure by considering a computer aided process not previously reported upon. Two methods of lexicological analysis, manual and automatic, were examined…
Computer-Aided College Algebra: Learning Components that Students Find Beneficial
ERIC Educational Resources Information Center
Aichele, Douglas B.; Francisco, Cynthia; Utley, Juliana; Wescoatt, Benjamin
2011-01-01
A mixed-method study was conducted during the Fall 2008 semester to better understand the experiences of students participating in computer-aided instruction of College Algebra using the software MyMathLab. The learning environment included a computer learning system for the majority of the instruction, a support system via focus groups (weekly…
Computer Aided Instruction: A Study of Student Evaluations and Academic Performance
ERIC Educational Resources Information Center
Collins, David; Deck, Alan; McCrickard, Myra
2008-01-01
Computer aided instruction (CAI) encompasses a broad range of computer technologies that supplement the classroom learning environment and can dramatically increase a student's access to information. Criticism of CAI generally focuses on two issues: it lacks an adequate foundation in educational theory and the software is difficult to implement…
Using Computer Graphics in the 90's.
ERIC Educational Resources Information Center
Towne, Violet A.
Computer-Aided Design, a hands-on program for public school teachers, was first offered in the summer of 1987 as an outgrowth of a 1986 robotics training program. Area technology teachers needed computer-aided design (CAD) training because of a New York State Education system transition from the industrial arts curriculum to a new curriculum in…
ERIC Educational Resources Information Center
Wild, Mary
2009-01-01
The paper reports the results of a randomised control trial investigating the use of computer-aided instruction (CAI) for practising phonological awareness skills with beginning readers. Two intervention groups followed the same phonological awareness programme: one group undertook practice exercises using a computer and the other group undertook…
The Impact of Software on Associate Degree Programs in Electronic Engineering Technology.
ERIC Educational Resources Information Center
Hata, David M.
1986-01-01
Assesses the range and extent of computer assisted instruction software available in electronic engineering technology education. Examines the need for software skills in four areas: (1) high-level languages; (2) assembly language; (3) computer-aided engineering; and (4) computer-aided instruction. Outlines strategies for the future in three…
Computer Code Aids Design Of Wings
NASA Technical Reports Server (NTRS)
Carlson, Harry W.; Darden, Christine M.
1993-01-01
AERO2S computer code developed to aid design engineers in selection and evaluation of aerodynamically efficient wing/canard and wing/horizontal-tail configurations that includes simple hinged-flap systems. Code rapidly estimates longitudinal aerodynamic characteristics of conceptual airplane lifting-surface arrangements. Developed in FORTRAN V on CDC 6000 computer system, and ported to MS-DOS environment.
Computer Aided Grid Interface: An Interactive CFD Pre-Processor
NASA Technical Reports Server (NTRS)
Soni, Bharat K.
1997-01-01
NASA maintains an applications oriented computational fluid dynamics (CFD) efforts complementary to and in support of the aerodynamic-propulsion design and test activities. This is especially true at NASA/MSFC where the goal is to advance and optimize present and future liquid-fueled rocket engines. Numerical grid generation plays a significant role in the fluid flow simulations utilizing CFD. An overall goal of the current project was to develop a geometry-grid generation tool that will help engineers, scientists and CFD practitioners to analyze design problems involving complex geometries in a timely fashion. This goal is accomplished by developing the CAGI: Computer Aided Grid Interface system. The CAGI system is developed by integrating CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) geometric system output and/or Initial Graphics Exchange Specification (IGES) files (including all the NASA-IGES entities), geometry manipulations and generations associated with grid constructions, and robust grid generation methodologies. This report describes the development process of the CAGI system.
Computer Aided Grid Interface: An Interactive CFD Pre-Processor
NASA Technical Reports Server (NTRS)
Soni, Bharat K.
1996-01-01
NASA maintains an applications oriented computational fluid dynamics (CFD) efforts complementary to and in support of the aerodynamic-propulsion design and test activities. This is especially true at NASA/MSFC where the goal is to advance and optimize present and future liquid-fueled rocket engines. Numerical grid generation plays a significant role in the fluid flow simulations utilizing CFD. An overall goal of the current project was to develop a geometry-grid generation tool that will help engineers, scientists and CFD practitioners to analyze design problems involving complex geometries in a timely fashion. This goal is accomplished by developing the Computer Aided Grid Interface system (CAGI). The CAGI system is developed by integrating CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) geometric system output and / or Initial Graphics Exchange Specification (IGES) files (including all the NASA-IGES entities), geometry manipulations and generations associated with grid constructions, and robust grid generation methodologies. This report describes the development process of the CAGI system.
Xu, Xiayu; Ding, Wenxiang; Abràmoff, Michael D; Cao, Ruofan
2017-04-01
Retinal artery and vein classification is an important task for the automatic computer-aided diagnosis of various eye diseases and systemic diseases. This paper presents an improved supervised artery and vein classification method in retinal image. Intra-image regularization and inter-subject normalization is applied to reduce the differences in feature space. Novel features, including first-order and second-order texture features, are utilized to capture the discriminating characteristics of arteries and veins. The proposed method was tested on the DRIVE dataset and achieved an overall accuracy of 0.923. This retinal artery and vein classification algorithm serves as a potentially important tool for the early diagnosis of various diseases, including diabetic retinopathy and cardiovascular diseases. Copyright © 2017 Elsevier B.V. All rights reserved.
An intelligent tutoring system for space shuttle diagnosis
NASA Technical Reports Server (NTRS)
Johnson, William B.; Norton, Jeffrey E.; Duncan, Phillip C.
1988-01-01
An Intelligent Tutoring System (ITS) transcends conventional computer-based instruction. An ITS is capable of monitoring and understanding student performance thereby providing feedback, explanation, and remediation. This is accomplished by including models of the student, the instructor, and the expert technician or operator in the domain of interest. The space shuttle fuel cell is the technical domain for the project described below. One system, Microcomputer Intelligence for Technical Training (MITT), demonstrates that ITS's can be developed and delivered, with a reasonable amount of effort and in a short period of time, on a microcomputer. The MITT system capitalizes on the diagnostic training approach called Framework for Aiding the Understanding of Logical Troubleshooting (FAULT) (Johnson, 1987). The system's embedded procedural expert was developed with NASA's C-Language Integrated Production (CLIP) expert system shell (Cubert, 1987).
Manufacturing engineering: Principles for optimization
NASA Astrophysics Data System (ADS)
Koenig, Daniel T.
Various subjects in the area of manufacturing engineering are addressed. The topics considered include: manufacturing engineering organization concepts and management techniques, factory capacity and loading techniques, capital equipment programs, machine tool and equipment selection and implementation, producibility engineering, methods, planning and work management, and process control engineering in job shops. Also discussed are: maintenance engineering, numerical control of machine tools, fundamentals of computer-aided design/computer-aided manufacture, computer-aided process planning and data collection, group technology basis for plant layout, environmental control and safety, and the Integrated Productivity Improvement Program.
Horsch, Alexander; Hapfelmeier, Alexander; Elter, Matthias
2011-11-01
Breast cancer is globally a major threat for women's health. Screening and adequate follow-up can significantly reduce the mortality from breast cancer. Human second reading of screening mammograms can increase breast cancer detection rates, whereas this has not been proven for current computer-aided detection systems as "second reader". Critical factors include the detection accuracy of the systems and the screening experience and training of the radiologist with the system. When assessing the performance of systems and system components, the choice of evaluation methods is particularly critical. Core assets herein are reference image databases and statistical methods. We have analyzed characteristics and usage of the currently largest publicly available mammography database, the Digital Database for Screening Mammography (DDSM) from the University of South Florida, in literature indexed in Medline, IEEE Xplore, SpringerLink, and SPIE, with respect to type of computer-aided diagnosis (CAD) (detection, CADe, or diagnostics, CADx), selection of database subsets, choice of evaluation method, and quality of descriptions. 59 publications presenting 106 evaluation studies met our selection criteria. In 54 studies (50.9%), the selection of test items (cases, images, regions of interest) extracted from the DDSM was not reproducible. Only 2 CADx studies, not any CADe studies, used the entire DDSM. The number of test items varies from 100 to 6000. Different statistical evaluation methods are chosen. Most common are train/test (34.9% of the studies), leave-one-out (23.6%), and N-fold cross-validation (18.9%). Database-related terminology tends to be imprecise or ambiguous, especially regarding the term "case". Overall, both the use of the DDSM as data source for evaluation of mammography CAD systems, and the application of statistical evaluation methods were found highly diverse. Results reported from different studies are therefore hardly comparable. Drawbacks of the DDSM (e.g. varying quality of lesion annotations) may contribute to the reasons. But larger bias seems to be caused by authors' own decisions upon study design. RECOMMENDATIONS/CONCLUSION: For future evaluation studies, we derive a set of 13 recommendations concerning the construction and usage of a test database, as well as the application of statistical evaluation methods.
Song, Yang; Zhang, Yu-Dong; Yan, Xu; Liu, Hui; Zhou, Minxiong; Hu, Bingwen; Yang, Guang
2018-04-16
Deep learning is the most promising methodology for automatic computer-aided diagnosis of prostate cancer (PCa) with multiparametric MRI (mp-MRI). To develop an automatic approach based on deep convolutional neural network (DCNN) to classify PCa and noncancerous tissues (NC) with mp-MRI. Retrospective. In all, 195 patients with localized PCa were collected from a PROSTATEx database. In total, 159/17/19 patients with 444/48/55 observations (215/23/23 PCas and 229/25/32 NCs) were randomly selected for training/validation/testing, respectively. T 2 -weighted, diffusion-weighted, and apparent diffusion coefficient images. A radiologist manually labeled the regions of interest of PCas and NCs and estimated the Prostate Imaging Reporting and Data System (PI-RADS) scores for each region. Inspired by VGG-Net, we designed a patch-based DCNN model to distinguish between PCa and NCs based on a combination of mp-MRI data. Additionally, an enhanced prediction method was used to improve the prediction accuracy. The performance of DCNN prediction was tested using a receiver operating characteristic (ROC) curve, and the area under the ROC curve (AUC), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Moreover, the predicted result was compared with the PI-RADS score to evaluate its clinical value using decision curve analysis. Two-sided Wilcoxon signed-rank test with statistical significance set at 0.05. The DCNN produced excellent diagnostic performance in distinguishing between PCa and NC for testing datasets with an AUC of 0.944 (95% confidence interval: 0.876-0.994), sensitivity of 87.0%, specificity of 90.6%, PPV of 87.0%, and NPV of 90.6%. The decision curve analysis revealed that the joint model of PI-RADS and DCNN provided additional net benefits compared with the DCNN model and the PI-RADS scheme. The proposed DCNN-based model with enhanced prediction yielded high performance in statistical analysis, suggesting that DCNN could be used in computer-aided diagnosis (CAD) for PCa classification. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.
Mazzoni, Simona; Marchetti, Claudio; Sgarzani, Rossella; Cipriani, Riccardo; Scotti, Roberto; Ciocca, Leonardo
2013-06-01
The aim of the present study was to evaluate the accuracy of prosthetically guided maxillofacial surgery in reconstructing the mandible with a free vascularized flap using custom-made bone plates and a surgical guide to cut the mandible and fibula. The surgical protocol was applied in a study group of seven consecutive mandibular-reconstructed patients who were compared with a control group treated using the standard preplating technique on stereolithographic models (indirect computer-aided design/computer-aided manufacturing method). The precision of both surgical techniques (prosthetically guided maxillofacial surgery and indirect computer-aided design/computer-aided manufacturing procedure) was evaluated by comparing preoperative and postoperative computed tomographic data and assessment of specific landmarks. With regard to midline deviation, no significant difference was documented between the test and control groups. With regard to mandibular angle shift, only one left angle shift on the lateral plane showed a statistically significant difference between the groups. With regard to angular deviation of the body axis, the data showed a significant difference in the arch deviation. All patients in the control group registered greater than 8 degrees of deviation, determining a facial contracture of the external profile at the lower margin of the mandible. With regard to condylar position, the postoperative condylar position was better in the test group than in the control group, although no significant difference was detected. The new protocol for mandibular reconstruction using computer-aided design/computer-aided manufacturing prosthetically guided maxillofacial surgery to construct custom-made guides and plates may represent a viable method of reproducing the patient's anatomical contour, giving the surgeon better procedural control and reducing procedure time. Therapeutic, III.
Computer-Aided Reliability Estimation
NASA Technical Reports Server (NTRS)
Bavuso, S. J.; Stiffler, J. J.; Bryant, L. A.; Petersen, P. L.
1986-01-01
CARE III (Computer-Aided Reliability Estimation, Third Generation) helps estimate reliability of complex, redundant, fault-tolerant systems. Program specifically designed for evaluation of fault-tolerant avionics systems. However, CARE III general enough for use in evaluation of other systems as well.
Effectiveness of educational technology to improve patient care in pharmacy curricula.
Smith, Michael A; Benedict, Neal
2015-02-17
A review of the literature on the effectiveness of educational technologies to teach patient care skills to pharmacy students was conducted. Nineteen articles met inclusion criteria for the review. Seven of the articles included computer-aided instruction, 4 utilized human-patient simulation, 1 used both computer-aided instruction and human-patient simulation, and 7 utilized virtual patients. Educational technology was employed with more than 2700 students at 12 colleges and schools of pharmacy in courses including pharmacotherapeutics, skills and patient care laboratories, drug diversion, and advanced pharmacy practice experience (APPE) orientation. Students who learned by means of human-patient simulation and virtual patients reported enjoying the learning activity, whereas the results with computer-aided instruction were mixed. Moreover, the effect on learning was significant in the human-patient simulation and virtual patient studies, while conflicting data emerged on the effectiveness of computer-aided instruction.
Baroudi, Kusai; Ibraheem, Shukran Nasser
2015-01-01
Background: This paper aimed to evaluate the application of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and the factors that affect the survival of restorations. Materials and Methods: A thorough literature search using PubMed, Medline, Embase, Science Direct, Wiley Online Library and Grey literature were performed from the year 2004 up to June 2014. Only relevant research was considered. Results: The use of chair-side CAD/CAM systems is promising in all dental branches in terms of minimizing time and effort made by dentists, technicians and patients for restoring and maintaining patient oral function and aesthetic, while providing high quality outcome. Conclusion: The way of producing and placing the restorations made with the chair-side CAD/CAM (CEREC and E4D) devices is better than restorations made by conventional laboratory procedures. PMID:25954082
Computer-aided design/computer-aided manufacturing skull base drill.
Couldwell, William T; MacDonald, Joel D; Thomas, Charles L; Hansen, Bradley C; Lapalikar, Aniruddha; Thakkar, Bharat; Balaji, Alagar K
2017-05-01
The authors have developed a simple device for computer-aided design/computer-aided manufacturing (CAD-CAM) that uses an image-guided system to define a cutting tool path that is shared with a surgical machining system for drilling bone. Information from 2D images (obtained via CT and MRI) is transmitted to a processor that produces a 3D image. The processor generates code defining an optimized cutting tool path, which is sent to a surgical machining system that can drill the desired portion of bone. This tool has applications for bone removal in both cranial and spine neurosurgical approaches. Such applications have the potential to reduce surgical time and associated complications such as infection or blood loss. The device enables rapid removal of bone within 1 mm of vital structures. The validity of such a machining tool is exemplified in the rapid (< 3 minutes machining time) and accurate removal of bone for transtemporal (for example, translabyrinthine) approaches.
The Research of Computer Aided Farm Machinery Designing Method Based on Ergonomics
NASA Astrophysics Data System (ADS)
Gao, Xiyin; Li, Xinling; Song, Qiang; Zheng, Ying
Along with agricultural economy development, the farm machinery product type Increases gradually, the ergonomics question is also getting more and more prominent. The widespread application of computer aided machinery design makes it possible that farm machinery design is intuitive, flexible and convenient. At present, because the developed computer aided ergonomics software has not suitable human body database, which is needed in view of farm machinery design in China, the farm machinery design have deviation in ergonomics analysis. This article puts forward that using the open database interface procedure in CATIA to establish human body database which aims at the farm machinery design, and reading the human body data to ergonomics module of CATIA can product practical application virtual body, using human posture analysis and human activity analysis module to analysis the ergonomics in farm machinery, thus computer aided farm machinery designing method based on engineering can be realized.
An esthetics rehabilitation with computer-aided design/ computer-aided manufacturing technology.
Mazaro, Josá Vitor Quinelli; de Mello, Caroline Cantieri; Zavanelli, Adriana Cristina; Santiago, Joel Ferreira; Amoroso, Andressa Paschoal; Pellizzer, Eduardo Piza
2014-07-01
This paper describes a case of a rehabilitation involving Computer Aided Design/Computer Aided Manufacturing (CAD-CAM) system in implant supported and dental supported prostheses using zirconia as framework. The CAD-CAM technology has developed considerably over last few years, becoming a reality in dental practice. Among the widely used systems are the systems based on zirconia which demonstrate important physical and mechanical properties of high strength, adequate fracture toughness, biocompatibility and esthetics, and are indicated for unitary prosthetic restorations and posterior and anterior framework. All the modeling was performed by using CAD-CAM system and prostheses were cemented using resin cement best suited for each situation. The rehabilitation of the maxillary arch using zirconia framework demonstrated satisfactory esthetic and functional results after a 12-month control and revealed no biological and technical complications. This article shows the important of use technology CAD/CAM in the manufacture of dental prosthesis and implant-supported.
NASA Astrophysics Data System (ADS)
Liu, George S.; Kim, Jinkyung; Applegate, Brian E.; Oghalai, John S.
2017-07-01
Diseases that cause hearing loss and/or vertigo in humans such as Meniere's disease are often studied using animal models. The volume of endolymph within the inner ear varies with these diseases. Here, we used a mouse model of increased endolymph volume, endolymphatic hydrops, to develop a computer-aided objective approach to measure endolymph volume from images collected in vivo using optical coherence tomography. The displacement of Reissner's membrane from its normal position was measured in cochlear cross sections. We validated our computer-aided measurements with manual measurements and with trained observer labels. This approach allows for computer-aided detection of endolymphatic hydrops in mice, with test performance showing sensitivity of 91% and specificity of 87% using a running average of five measurements. These findings indicate that this approach is accurate and reliable for classifying endolymphatic hydrops and quantifying endolymph volume.
Development and Validation of Diagnostic Economics Test for Secondary Schools
ERIC Educational Resources Information Center
Eleje, Lydia I.; Esomonu, Nkechi P. M.; Agu, Ngozi N.; Okoye, Romy O.; Obasi, Emma; Onah, Frederick E.
2016-01-01
A diagnostic test in economics to aid the teachers determine student's specific weak content areas was developed and validated. Five research questions guided the study. Preliminary validation was done by two experienced teachers in the content area of secondary economics and two experts in test construction. The pilot testing was conducted for…
2013-01-01
An HIV-1 diagnostic laboratory was established in the Academic Medical Center (AMC) of the University of Amsterdam after the discovery of human immunodeficiency virus (HIV) as the cause of the acquired immunodeficiency syndrome (AIDS). The first AIDS patients were diagnosed here in 1981 and since 1983 we have tested the samples of 50992 patients using a variety of assays that greatly improved over the years. We will describe some of the basic results from this diagnostic laboratory and then focus on the spin-off in terms of the development of novel virus assays to detect super-infections and ultra-sensitive assays to measure the intracellular HIV-1 RNA load. We also review several original research findings in the field of HIV-1 virology that stem from initial observations made in the diagnostic unit. This includes the study of genetic defects in the HIV-1 genome and time trends of the replication fitness over 30 years of viral evolution, but also the description of novel HIV-1 variants in difficult-to-diagnose clinical specimen. PMID:23985078
van der Kuyl, Antoinette C; Bakker, Margreet; Jurriaans, Suzanne; Back, Nicole K T; Pasternak, Alexander O; Cornelissen, Marion; Berkhout, Ben
2013-08-28
An HIV-1 diagnostic laboratory was established in the Academic Medical Center (AMC) of the University of Amsterdam after the discovery of human immunodeficiency virus (HIV) as the cause of the acquired immunodeficiency syndrome (AIDS). The first AIDS patients were diagnosed here in 1981 and since 1983 we have tested the samples of 50992 patients using a variety of assays that greatly improved over the years. We will describe some of the basic results from this diagnostic laboratory and then focus on the spin-off in terms of the development of novel virus assays to detect super-infections and ultra-sensitive assays to measure the intracellular HIV-1 RNA load. We also review several original research findings in the field of HIV-1 virology that stem from initial observations made in the diagnostic unit. This includes the study of genetic defects in the HIV-1 genome and time trends of the replication fitness over 30 years of viral evolution, but also the description of novel HIV-1 variants in difficult-to-diagnose clinical specimen.
Carruth, Lauren
2014-11-01
This paper details how exposure to new clinics, diagnostic technologies, and pharmaceuticals during humanitarian relief operations in the Somali Region of Ethiopia shaped local pluralistic health systems and altered the ways in which residents subsequently conceived of and treated illness and disease. Despite rising demand for pharmaceuticals and diagnostic technologies among Somalis in Ethiopia, local ethnophysiologies continued to draw upon popular ideas about humoral flows, divine action, and spirit possession. Demands for therapeutic camel milk, Qur'anic spiritual healing, herbal remedies, and other historically popular therapies persisted, but were shaped by concurrent demands for and understandings of diagnostic biotechnologies and pharmaceutical medications. The reverse was also true: contemporary understandings and uses of non-biomedical healing modalities among Somalis shaped evaluations of clinical care, including healthcare during humanitarian responses. To illustrate these phenomena, based on ethnographic research in eastern Ethiopia between 2007 and 2009, this paper explores three topics vital to Somalis' pluralistic healthcare systems: camel milk and the management of digestive bile; women's experiences and clinical presentations with pain and disorder in their reproductive systems; and the rising popularity of high-tech diagnostic tests. I conclude that medical humanitarian aid never happens in a vacuum or among truly treatment-naïve populations. Instead, aid unfolds within ever-changing and pluralistic health cultures, and it permanently alters and is altered by the frames within which people evaluate and make future decisions about healthcare. Copyright © 2014 Elsevier Ltd. All rights reserved.
Lejoy, Abraham; Arpita, Rai; Krishna, Burde; Venkatesh, Naikmasur
2016-05-01
In vivo stains are the prompt resources, which have emerged in recent years to aid as clinical diagnostic tools in detecting early potentially malignant and malignant lesions. Toluidine blue, by its property of retaining in the increased DNA and RNA cellular activity areas, aids in delineating the suspicious areas. However, it is hazardous if swallowed, and has been shown to have toxicity to fibroblasts. Methylene blue has a similar chemical structure and exhibits similar physicochemical properties as toluidine blue. It is less toxic to the human body and has recently been proposed for screening some gastrointestinal or prostate tumors. The application of this material in detecting oral lesions has so far not been addressed. The objective of this study was to evaluate the sensitivity and reliability of in vivo staining with methylene blue as a diagnostic adjunct in screening for oral malignant or potentially malignant lesions. The present study involved the examination of 75 patients suspected of having oral malignant or potentially malignant lesions by methylene blue staining. The results of methylene blue uptake were compared with a simultaneous biopsy of these lesions. The overall sensitivity was 95% (100% for malignancy and 92% for potentially malignant lesions) and specificity was 70%. The positive predictive value was 91% and negative predictive value of 80% was observed in the study. We consider that methylene blue staining is a useful diagnostic adjunct in a large, community-based oral cancer screening program for high-risk individuals.
Computer-Aided Diagnosis in Medical Imaging: Historical Review, Current Status and Future Potential
Doi, Kunio
2007-01-01
Computer-aided diagnosis (CAD) has become one of the major research subjects in medical imaging and diagnostic radiology. In this article, the motivation and philosophy for early development of CAD schemes are presented together with the current status and future potential of CAD in a PACS environment. With CAD, radiologists use the computer output as a “second opinion” and make the final decisions. CAD is a concept established by taking into account equally the roles of physicians and computers, whereas automated computer diagnosis is a concept based on computer algorithms only. With CAD, the performance by computers does not have to be comparable to or better than that by physicians, but needs to be complementary to that by physicians. In fact, a large number of CAD systems have been employed for assisting physicians in the early detection of breast cancers on mammograms. A CAD scheme that makes use of lateral chest images has the potential to improve the overall performance in the detection of lung nodules when combined with another CAD scheme for PA chest images. Because vertebral fractures can be detected reliably by computer on lateral chest radiographs, radiologists’ accuracy in the detection of vertebral fractures would be improved by the use of CAD, and thus early diagnosis of osteoporosis would become possible. In MRA, a CAD system has been developed for assisting radiologists in the detection of intracranial aneurysms. On successive bone scan images, a CAD scheme for detection of interval changes has been developed by use of temporal subtraction images. In the future, many CAD schemes could be assembled as packages and implemented as a part of PACS. For example, the package for chest CAD may include the computerized detection of lung nodules, interstitial opacities, cardiomegaly, vertebral fractures, and interval changes in chest radiographs as well as the computerized classification of benign and malignant nodules and the differential diagnosis of interstitial lung diseases. In order to assist in the differential diagnosis, it would be possible to search for and retrieve images (or lesions) with known pathology, which would be very similar to a new unknown case, from PACS when a reliable and useful method has been developed for quantifying the similarity of a pair of images for visual comparison by radiologists. PMID:17349778
Computer Aided Dosimetry and Verification of Exposure to Radiation
2002-06-01
Event matrix 2. Hematopoietic * Absolute blood counts * Relative blood counts 3. Dosimetry * TLD * EPDQuantitative * Radiation survey * Whole body...EI1 Defence Research and Recherche et developpement Development Canada pour la d6fense Canada DEFENCE •mI•DEFENSE Computer Aided Dosimetry and...Aided Dosimetry and Verification of Exposure to Radiation Edward Waller SAIC Canada Robert Z Stodilka Radiation Effects Group, Space Systems and
[Gdansk HIV-AIDS project, yesterday, today and future].
Zielińska, W
1995-09-01
Medical care project for HIV positive and AIDS patients in Gdańsk voivodship was established in 1988 in the Clinic for Infectious Diseases of Gdańsk Medical University. The aim of this modern and multidirectional program was to provide full medical care for HIV/AIDS patients and introduce effective prophylaxis against spread of HIV infection. According to the project-clinical ward, outpatient clinic for HIV positive and AIDS patients, diagnostic and laboratory units, were established. Close cooperation including specialistic and general medical care, was set with detoxication ward, rehabilitation centers for drug addicts, prison medical services and the Korczak Orphanage. Education of medical staff and some social groups was provided (teachers, teenagers of secondary schools, journalists, police employees). Clinical ward for HIV positive patients who are in need of inpatient medical care is localized in the Clinic for Infectious Diseases of Gdańsk Medical University. The ward has 16 double - bed Melcer's boxes which are used for other HIV/AIDS patients according to present needs. Free beds are used for HIV negative patients. HIV/AIDS Outpatient Clinic is localized in Venerologic Outpatient Unit. This was because of some psychological, social, professional and organization aspects. Outpatient Clinic staff is responsible for first patients' examination. Serological diagnostics of HIV infection is follow up for everyone (anonymous testing is possible); testing for STD is available also. Diagnostic laboratory base for clinical ward and other units are the laboratories of Gdańsk Voivodship Hospital for Infectious Diseases. Clinic for Infectious Diseases supervises all co-operating units. These are the following: 10-beds detoxication ward for drug addicts in Psychiatric - Neurological Hospital "Srebrzysko", 70-80 places in rehabilitation centers for drug addicts in Zapowiednik and Smazyno, remand prison ward for HIV positive patients (this is the first ward established in Poland, thanks to our initiative, in 1990). One of very important units of our Center is the Korczak Orphanage for children aged 0-7 years, which is subjected to Voivodship Health Department. This orphanage is the place for children with positive HIV serology from the whole Poland. Children who need inpatient medical care, among them AIDS children, are admitted to the Clinic for Infectious Diseases and can be diagnosed and consulted in all units of Gdańsk Medical University. In 1992 the co-operation with Gdańsk homosexual society represented by the Gdańsk Initiative (a submit of Lambda organization), was established. Education program is the next very important part of the Clinical and Diagnostic HIV/AIDS Center work. Until now medical staff and Education Department staff were mainly concerned. It is planned to establish Voivodship Social Needs Outpatient Clinic which would continue all hitherto activities, which would be extended by social law counseling. Such outpatient clinic would facilitate education activity. It would be the base for medical research on social pathology and HIV/AIDS related problems.
Benefit-risk Evaluation for Diagnostics: A Framework (BED-FRAME).
Evans, Scott R; Pennello, Gene; Pantoja-Galicia, Norberto; Jiang, Hongyu; Hujer, Andrea M; Hujer, Kristine M; Manca, Claudia; Hill, Carol; Jacobs, Michael R; Chen, Liang; Patel, Robin; Kreiswirth, Barry N; Bonomo, Robert A
2016-09-15
The medical community needs systematic and pragmatic approaches for evaluating the benefit-risk trade-offs of diagnostics that assist in medical decision making. Benefit-Risk Evaluation of Diagnostics: A Framework (BED-FRAME) is a strategy for pragmatic evaluation of diagnostics designed to supplement traditional approaches. BED-FRAME evaluates diagnostic yield and addresses 2 key issues: (1) that diagnostic yield depends on prevalence, and (2) that different diagnostic errors carry different clinical consequences. As such, evaluating and comparing diagnostics depends on prevalence and the relative importance of potential errors. BED-FRAME provides a tool for communicating the expected clinical impact of diagnostic application and the expected trade-offs of diagnostic alternatives. BED-FRAME is a useful fundamental supplement to the standard analysis of diagnostic studies that will aid in clinical decision making. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
ERIC Educational Resources Information Center
Pollard, Jim
This report reviews eight IBM-compatible software packages that are available to secondary schools to teach computer-aided drafting (CAD). Software packages to be considered were selected following reviews of CAD periodicals, computers in education periodicals, advertisements, and recommendations of teachers. The packages were then rated by…
ERIC Educational Resources Information Center
O'Brien, George M.
This paper reports on an on-going experiment in computer-aided language instruction. In 1972, a class of beginning German students at the Duluth campus of the University of Minnesota volunteered to test two pedagogic theories: (1) Could a computer-aided course be used by a class and an instructor who knew nothing of computers and who had to rely…
2011-02-01
Command CASE Computer Aided Software Engineering CASEVAC Casualty Evacuation CASTFOREM Combined Arms And Support Task Force Evaluation Model CAT Center For...Advanced Technologies CAT Civil Affairs Team CAT Combined Arms Training CAT Crew Integration CAT Crisis Action Team CATIA Computer-Aided Three...Dimensional Interactive Application CATOX Catalytic Oxidation CATS Combined Arms Training Strategy CATT Combined Arms Tactical Trainer CATT Computer
Quad-phased data mining modeling for dementia diagnosis.
Bang, Sunjoo; Son, Sangjoon; Roh, Hyunwoong; Lee, Jihye; Bae, Sungyun; Lee, Kyungwon; Hong, Changhyung; Shin, Hyunjung
2017-05-18
The number of people with dementia is increasing along with people's ageing trend worldwide. Therefore, there are various researches to improve a dementia diagnosis process in the field of computer-aided diagnosis (CAD) technology. The most significant issue is that the evaluation processes by physician which is based on medical information for patients and questionnaire from their guardians are time consuming, subjective and prone to error. This problem can be solved by an overall data mining modeling, which subsidizes an intuitive decision of clinicians. Therefore, in this paper we propose a quad-phased data mining modeling consisting of 4 modules. In Proposer Module, significant diagnostic criteria are selected that are effective for diagnostics. Then in Predictor Module, a model is constructed to predict and diagnose dementia based on a machine learning algorism. To help clinical physicians understand results of the predictive model better, in Descriptor Module, we interpret causes of diagnostics by profiling patient groups. Lastly, in Visualization Module, we provide visualization to effectively explore characteristics of patient groups. The proposed model is applied for CREDOS study which contains clinical data collected from 37 university-affiliated hospitals in republic of Korea from year 2005 to 2013. This research is an intelligent system enabling intuitive collaboration between CAD system and physicians. And also, improved evaluation process is able to effectively reduce time and cost consuming for clinicians and patients.
Lee, Jae-Hong; Kim, Do-Hyung; Jeong, Seong-Nyum; Choi, Seong-Ho
2018-04-01
The aim of the current study was to develop a computer-assisted detection system based on a deep convolutional neural network (CNN) algorithm and to evaluate the potential usefulness and accuracy of this system for the diagnosis and prediction of periodontally compromised teeth (PCT). Combining pretrained deep CNN architecture and a self-trained network, periapical radiographic images were used to determine the optimal CNN algorithm and weights. The diagnostic and predictive accuracy, sensitivity, specificity, positive predictive value, negative predictive value, receiver operating characteristic (ROC) curve, area under the ROC curve, confusion matrix, and 95% confidence intervals (CIs) were calculated using our deep CNN algorithm, based on a Keras framework in Python. The periapical radiographic dataset was split into training (n=1,044), validation (n=348), and test (n=348) datasets. With the deep learning algorithm, the diagnostic accuracy for PCT was 81.0% for premolars and 76.7% for molars. Using 64 premolars and 64 molars that were clinically diagnosed as severe PCT, the accuracy of predicting extraction was 82.8% (95% CI, 70.1%-91.2%) for premolars and 73.4% (95% CI, 59.9%-84.0%) for molars. We demonstrated that the deep CNN algorithm was useful for assessing the diagnosis and predictability of PCT. Therefore, with further optimization of the PCT dataset and improvements in the algorithm, a computer-aided detection system can be expected to become an effective and efficient method of diagnosing and predicting PCT.
ERIC Educational Resources Information Center
Lake County Area Vocational Center, Grayslake, IL.
This task analysis for nursing education provides performance standards, steps to be followed, knowledge required, attitudes to be developed, safety procedures, and equipment and supplies needed for 13 tasks performed by geriatric aides in the duty area of performing diagnostic measures and for 30 tasks in the duty area of providing therapeutic…
Longo, F; Nicetto, T; Banzato, T; Savio, G; Drigo, M; Meneghello, R; Concheri, G; Isola, M
2018-02-01
The aim of this ex vivo study was to test a novel three-dimensional (3D) automated computer-aided design (CAD) method (aCAD) for the computation of femoral angles in dogs from 3D reconstructions of computed tomography (CT) images. The repeatability and reproducibility of three manual radiography, manual CT reconstructions and the aCAD method for the measurement of three femoral angles were evaluated: (1) anatomical lateral distal femoral angle (aLDFA); (2) femoral neck angle (FNA); and (3) femoral torsion angle (FTA). Femoral angles of 22 femurs obtained from 16 cadavers were measured by three blinded observers. Measurements were repeated three times by each observer for each diagnostic technique. Femoral angle measurements were analysed using a mixed effects linear model for repeated measures to determine the levels of intra-observer agreement (repeatability) and inter-observer agreement (reproducibility). Repeatability and reproducibility of measurements using the aCAD method were excellent (intra-class coefficients, ICCs≥0.98) for all three angles assessed. Manual radiography and CT exhibited excellent agreement for the aLDFA measurement (ICCs≥0.90). However, FNA repeatability and reproducibility were poor (ICCs<0.8), whereas FTA measurement showed slightly higher ICCs values, except for the radiographic reproducibility, which was poor (ICCs<0.8). The computation of the 3D aCAD method provided the highest repeatability and reproducibility among the tested methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.
A comprehensive review of diagnostic and treatment options for granulosa cell tumors of the ovary.
Stine, Jessica E; Pierce, Stuart; Soper, John T
2014-01-01
Granulosa cell tumors are rare and comprise approximately 2% to 8% of all ovarian malignancies. Research dedicated to these tumors is rare given the low incidence. These tumors are more difficult to diagnose than epithelial ovarian tumors, and understanding how they present may aid in appropriate referral to a gynecologic oncologist. The aim of this review was to summarize the epidemiology, risk factors, and clinical presentation of granulosa cell tumors to aid in provider recognition. We will also explore current diagnostic and treatment modalities with examination of newer, novel treatments. At the end of this review, the reader should understand how to appropriately diagnose and treat these rare malignancies.
Gluckman, R J; Rosner, F; Guarneri, J J
1989-02-01
Diagnostic bone marrow aspiration, biopsy, and culture are useful procedures in the evaluation of patients with suspected or proven acquired immunodeficiency syndrome (AIDS) who are febrile. In as many as one fourth of these patients, the information provided by the bone marrow examination may establish a diagnosis of a disseminated opportunistic infection when other studies are not informative. We have also discovered a previously unreported association between thrombocytopenia and the presence of bone marrow granulomas in our patients with AIDS and suggest that thrombocytopenia may be a clue to enable the clinician to predict a positive bone marrow result more accurately. The explanation for this apparent association remains to be elucidated.
Fukunishi, Yoshifumi; Mashimo, Tadaaki; Misoo, Kiyotaka; Wakabayashi, Yoshinori; Miyaki, Toshiaki; Ohta, Seiji; Nakamura, Mayu; Ikeda, Kazuyoshi
2016-01-01
Computer-aided drug design is still a state-of-the-art process in medicinal chemistry, and the main topics in this field have been extensively studied and well reviewed. These topics include compound databases, ligand-binding pocket prediction, protein-compound docking, virtual screening, target/off-target prediction, physical property prediction, molecular simulation and pharmacokinetics/pharmacodynamics (PK/PD) prediction. Message and Conclusion: However, there are also a number of secondary or miscellaneous topics that have been less well covered. For example, methods for synthesizing and predicting the synthetic accessibility (SA) of designed compounds are important in practical drug development, and hardware/software resources for performing the computations in computer-aided drug design are crucial. Cloud computing and general purpose graphics processing unit (GPGPU) computing have been used in virtual screening and molecular dynamics simulations. Not surprisingly, there is a growing demand for computer systems which combine these resources. In the present review, we summarize and discuss these various topics of drug design.
Fukunishi, Yoshifumi; Mashimo, Tadaaki; Misoo, Kiyotaka; Wakabayashi, Yoshinori; Miyaki, Toshiaki; Ohta, Seiji; Nakamura, Mayu; Ikeda, Kazuyoshi
2016-01-01
Abstract: Background Computer-aided drug design is still a state-of-the-art process in medicinal chemistry, and the main topics in this field have been extensively studied and well reviewed. These topics include compound databases, ligand-binding pocket prediction, protein-compound docking, virtual screening, target/off-target prediction, physical property prediction, molecular simulation and pharmacokinetics/pharmacodynamics (PK/PD) prediction. Message and Conclusion: However, there are also a number of secondary or miscellaneous topics that have been less well covered. For example, methods for synthesizing and predicting the synthetic accessibility (SA) of designed compounds are important in practical drug development, and hardware/software resources for performing the computations in computer-aided drug design are crucial. Cloud computing and general purpose graphics processing unit (GPGPU) computing have been used in virtual screening and molecular dynamics simulations. Not surprisingly, there is a growing demand for computer systems which combine these resources. In the present review, we summarize and discuss these various topics of drug design. PMID:27075578
ERIC Educational Resources Information Center
Manning, S.; Dix, A.
2008-01-01
There is anecdotal evidence that a significant number of students studying computing related courses at degree level have difficulty with sub-GCE mathematics. Testing of students' skills is often performed using diagnostic tests and a number of computer-based diagnostic tests exist, which work, essentially, by testing one specific diagnostic skill…
Garg, Amit Kumar; Bhardwaj, Anuj; Mantri, Vijay R; Agrawal, Neha
2014-05-01
A case of unusual Root morphology is presented to demonstrate anatomic variations in mandibular third molar. The most common configuration of mandibular third molar is two Roots and three canals; however they may have many different combinations. Endodontic treatment was performed in mandibular third molar having aberrant anatomy. Four Root canal orifices were located with the aid of dental operating microscope (DOM) and three separate Roots were diagnosed with radiographs. Spiral computed tomography (SCT) showed the presence of an extra canal and extra Root, indicating a rare anatomic configuration. Looking for additional canals and Roots are important part of successful endodontics, as the knowledge of their existence enable clinicians to treat a case successfully that otherwise might end in failure. The use of DOM and SCT in this case greatly contributed toward making a confirmatory diagnosis and successful endodontic treatment of four-rooted and five-canalled mandibular third molar. Variation in Root canal anatomy is very common. Knowledge of these variations is very essential for successful Root canal outcome, inability to do so can lead to missed canals and failures. Hence, thorough knowledge of Root canal anatomy and advances in diagnostic aids are essential.
Shaded-Color Picture Generation of Computer-Defined Arbitrary Shapes
NASA Technical Reports Server (NTRS)
Cozzolongo, J. V.; Hermstad, D. L.; Mccoy, D. S.; Clark, J.
1986-01-01
SHADE computer program generates realistic color-shaded pictures from computer-defined arbitrary shapes. Objects defined for computer representation displayed as smooth, color-shaded surfaces, including varying degrees of transparency. Results also used for presentation of computational results. By performing color mapping, SHADE colors model surface to display analysis results as pressures, stresses, and temperatures. NASA has used SHADE extensively in sign and analysis of high-performance aircraft. Industry should find applications for SHADE in computer-aided design and computer-aided manufacturing. SHADE written in VAX FORTRAN and MACRO Assembler for either interactive or batch execution.
DOT National Transportation Integrated Search
2003-10-01
The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : WSDOT deployment". This document defines the objective, approach,...
DOT National Transportation Integrated Search
2006-05-01
This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch - Traffic Management Center Integration Field Operations Test in the State of Washington. The document discusses evaluation findings in the foll...
DOT National Transportation Integrated Search
1999-09-01
This report documents what happened to employees' work procedures when their employer when their employer installed Computer Aided Disptach/Automatic Vehicle Locator (CAD/AVL) technology to provide real-time surveillance of vehicles and to upgrade ra...
The University of Michigan's Computer-Aided Engineering Network.
ERIC Educational Resources Information Center
Atkins, D. E.; Olsen, Leslie A.
1986-01-01
Presents an overview of the Computer-Aided Engineering Network (CAEN) of the University of Michigan. Describes its arrangement of workstations, communication networks, and servers. Outlines the factors considered in hardware and software decision making. Reviews the program's impact on students. (ML)
Computer-aided engineering of semiconductor integrated circuits
NASA Astrophysics Data System (ADS)
Meindl, J. D.; Dutton, R. W.; Gibbons, J. F.; Helms, C. R.; Plummer, J. D.; Tiller, W. A.; Ho, C. P.; Saraswat, K. C.; Deal, B. E.; Kamins, T. I.
1980-07-01
Economical procurement of small quantities of high performance custom integrated circuits for military systems is impeded by inadequate process, device and circuit models that handicap low cost computer aided design. The principal objective of this program is to formulate physical models of fabrication processes, devices and circuits to allow total computer-aided design of custom large-scale integrated circuits. The basic areas under investigation are (1) thermal oxidation, (2) ion implantation and diffusion, (3) chemical vapor deposition of silicon and refractory metal silicides, (4) device simulation and analytic measurements. This report discusses the fourth year of the program.
CAD system for footwear design based on whole real 3D data of last surface
NASA Astrophysics Data System (ADS)
Song, Wanzhong; Su, Xianyu
2000-10-01
Two major parts of application of CAD in footwear design are studied: the development of last surface; computer-aided design of planar shoe-template. A new quasi-experiential development algorithm of last surface based on triangulation approximation is presented. This development algorithm consumes less time and does not need any interactive operation for precisely development compared with other development algorithm of last surface. Based on this algorithm, a software, SHOEMAKERTM, which contains computer aided automatic measurement, automatic development of last surface and computer aide design of shoe-template has been developed.
Radiological interpretation of images displayed on tablet computers: a systematic review.
Caffery, L J; Armfield, N R; Smith, A C
2015-06-01
To review the published evidence and to determine if radiological diagnostic accuracy is compromised when images are displayed on a tablet computer and thereby inform practice on using tablet computers for radiological interpretation by on-call radiologists. We searched the PubMed and EMBASE databases for studies on the diagnostic accuracy or diagnostic reliability of images interpreted on tablet computers. Studies were screened for inclusion based on pre-determined inclusion and exclusion criteria. Studies were assessed for quality and risk of bias using Quality Appraisal of Diagnostic Reliability Studies or the revised Quality Assessment of Diagnostic Accuracy Studies tool. Treatment of studies was reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). 11 studies met the inclusion criteria. 10 of these studies tested the Apple iPad(®) (Apple, Cupertino, CA). The included studies reported high sensitivity (84-98%), specificity (74-100%) and accuracy rates (98-100%) for radiological diagnosis. There was no statistically significant difference in accuracy between a tablet computer and a digital imaging and communication in medicine-calibrated control display. There was a near complete consensus from authors on the non-inferiority of diagnostic accuracy of images displayed on a tablet computer. All of the included studies were judged to be at risk of bias. Our findings suggest that the diagnostic accuracy of radiological interpretation is not compromised by using a tablet computer. This result is only relevant to the Apple iPad and to the modalities of CT, MRI and plain radiography. The iPad may be appropriate for an on-call radiologist to use for radiological interpretation.
Training Aids for Online Instruction: An Analysis.
ERIC Educational Resources Information Center
Guy, Robin Frederick
This paper describes a number of different types of training aids currently employed in online training: non-interactive audiovisual presentations; interactive computer-based aids; partially interactive aids based on recorded searches; print-based materials; and kits. The advantages and disadvantages of each type of aid are noted, and a table…
Financial Aid for Full-Time Undergraduates. Higher Education Panel Report Number 60.
ERIC Educational Resources Information Center
Andersen, Charles J.
The level and composition of student financial aid for undergraduate students were estimated, with attention to estimated number of aid recipients, the total amount they received, the distribution of aided students by their families' income level, the composition of their aid packages, and the use of computers in the administration of aid. In…
Skin-prick testing as a diagnostic aid for childhood asthma.
Chan, E Y; Dundas, I; Bridge, P D; Healy, M J R; McKenzie, S A
2005-06-01
Diagnosing asthma is problematic when based solely on reported symptoms. The purpose of this study was to evaluate skin-prick testing as a diagnostic aid for asthma in children. Skin-prick testing (SPT) was undertaken in children aged 2-10 years with either no history of wheeze (n = 149) or recent doctor-observed wheeze which responded to treatment with a bronchodilator, the "gold standard" (n = 164). Children with moderate or severe asthma were excluded. SPT positivity increased sharply at age 5 years in wheezers. Data were therefore divided into two age groups: 2- < 5 years (57 controls, 97 wheezers) and 5-10 years (92 controls, 67 wheezers). The sensitivity, specificity, and likelihood ratios of SPT positivity for wheeze were 32%, 89%, and 2.9, respectively, in the younger children, and 82%, 85%, and 5.5, respectively, in the older children. For a prevalence of 30% for asthma, the positive predictive values of a positive SPT were 55% and 70% for the younger and older age groups, respectively. The test characteristics of SPT for helping diagnose asthma in schoolchildren are good. The prevalence of wheeze in preschool children is high, and so SPT should be helpful even in this group. We suggest that clinicians consider skin-prick testing as a diagnostic aid for asthma. Copyright 2005 Wiley-Liss, Inc.
2017-08-08
Usability Studies In Virtual And Traditional Computer Aided Design Environments For Fault Identification Dr. Syed Adeel Ahmed, Xavier University...virtual environment with wand interfaces compared directly with a workstation non-stereoscopic traditional CAD interface with keyboard and mouse. In...the differences in interaction when compared with traditional human computer interfaces. This paper provides analysis via usability study methods
A State-of-the-Art Review of the Real-Time Computer-Aided Study of the Writing Process
ERIC Educational Resources Information Center
Abdel Latif, Muhammad M.
2008-01-01
Writing researchers have developed various methods for investigating the writing process since the 1970s. The early 1980s saw the occurrence of the real-time computer-aided study of the writing process that relies on the protocols generated by recording the computer screen activities as writers compose using the word processor. This article…
ERIC Educational Resources Information Center
National Center for State Courts, Williamsburg, VA.
This report summarizes the findings of the Computer-Aided Transcription (CAT) Project, which conducted a 14-month study of the technology and use of computer systems for translating into English the shorthand notes taken by court reporters on stenotype machines. Included are the state of the art of CAT at the end of 1980 and anticipated future…
Wusor II: A Computer Aided Instruction Program with Student Modelling Capabilities. AI Memo 417.
ERIC Educational Resources Information Center
Carr, Brian
Wusor II is the second intelligent computer aided instruction (ICAI) program that has been developed to monitor the progress of, and offer suggestions to, students playing Wumpus, a computer game designed to teach logical thinking and problem solving. From the earlier efforts with Wusor I, it was possible to produce a rule-based expert which…
The SIV plasma viral load assay performed by the Quantitative Molecular Diagnostics Core (QMDC) utilizes reagents specifically designed to detect and accurately quantify the full range of SIV/SHIV viral variants and clones in common usage in the rese
21 CFR 870.1435 - Single-function, preprogrammed diagnostic computer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Single-function, preprogrammed diagnostic computer. 870.1435 Section 870.1435 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1435...
Computational System For Rapid CFD Analysis In Engineering
NASA Technical Reports Server (NTRS)
Barson, Steven L.; Ascoli, Edward P.; Decroix, Michelle E.; Sindir, Munir M.
1995-01-01
Computational system comprising modular hardware and software sub-systems developed to accelerate and facilitate use of techniques of computational fluid dynamics (CFD) in engineering environment. Addresses integration of all aspects of CFD analysis process, including definition of hardware surfaces, generation of computational grids, CFD flow solution, and postprocessing. Incorporates interfaces for integration of all hardware and software tools needed to perform complete CFD analysis. Includes tools for efficient definition of flow geometry, generation of computational grids, computation of flows on grids, and postprocessing of flow data. System accepts geometric input from any of three basic sources: computer-aided design (CAD), computer-aided engineering (CAE), or definition by user.
Computers in medicine: patients' attitudes
Cruickshank, P. J.
1984-01-01
Data are presented from two surveys where a 26-item questionnaire was used to measure patients' attitudes to diagnostic computers and to medical computers in general. The first group of respondents were 229 patients who had been given outpatient appointments at a hospital general medical clinic specializing in gastrointestinal problems, where some had experienced a diagnostic computer in use. The second group of respondents were 416 patients attending a group general practice where there was no computer. Patients who had experience of the diagnostic computer or a personal computer had more favourable attitudes to computers in medicine as did younger people and males. The two samples of patients showed broadly similar attitudes, and a notable finding was that over half of each group believed that, with a computer around, the personal touch of the doctor would be lost. PMID:6471021
Unit cell-based computer-aided manufacturing system for tissue engineering.
Kang, Hyun-Wook; Park, Jeong Hun; Kang, Tae-Yun; Seol, Young-Joon; Cho, Dong-Woo
2012-03-01
Scaffolds play an important role in the regeneration of artificial tissues or organs. A scaffold is a porous structure with a micro-scale inner architecture in the range of several to several hundreds of micrometers. Therefore, computer-aided construction of scaffolds should provide sophisticated functionality for porous structure design and a tool path generation strategy that can achieve micro-scale architecture. In this study, a new unit cell-based computer-aided manufacturing (CAM) system was developed for the automated design and fabrication of a porous structure with micro-scale inner architecture that can be applied to composite tissue regeneration. The CAM system was developed by first defining a data structure for the computing process of a unit cell representing a single pore structure. Next, an algorithm and software were developed and applied to construct porous structures with a single or multiple pore design using solid freeform fabrication technology and a 3D tooth/spine computer-aided design model. We showed that this system is quite feasible for the design and fabrication of a scaffold for tissue engineering.
Code of Federal Regulations, 2014 CFR
2014-07-01
... adjuncts such as prosthetic devices, spectacles, hearing aids, orthopedic footwear, and other medically... retaining management, any additional material, professional diagnostic or consultative services, or other...
DOT National Transportation Integrated Search
2006-07-01
This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch Traffic Management Center Integration Field Operations Test in the State of Utah. The document discusses evaluation findings in the followin...
USE OF COMPUTER-AIDED PROCESS ENGINEERING TOOL IN POLLUTION PREVENTION
Computer-Aided Process Engineering has become established in industry as a design tool. With the establishment of the CAPE-OPEN software specifications for process simulation environments. CAPE-OPEN provides a set of "middleware" standards that enable software developers to acces...
ERIC Educational Resources Information Center
Boardman, D.
1979-01-01
Practical experience has shown that computer aided design programs can provide an invaluable aid in the learning process when integrated into the syllabus in lecture and laboratory periods. This should be a major area of future development of computer assisted learning in engineering education. (Author/CMV)
DOT National Transportation Integrated Search
2004-01-01
The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : state of Utah". This document defines the objective, approach, an...
Computer-Aided Geometry Modeling
NASA Technical Reports Server (NTRS)
Shoosmith, J. N. (Compiler); Fulton, R. E. (Compiler)
1984-01-01
Techniques in computer-aided geometry modeling and their application are addressed. Mathematical modeling, solid geometry models, management of geometric data, development of geometry standards, and interactive and graphic procedures are discussed. The applications include aeronautical and aerospace structures design, fluid flow modeling, and gas turbine design.
APPLICATION OF COMPUTER AIDED TOMOGRAPHY (CAT) TO THE STUDY OF MARINE BENTIC COMMUNITIES
Sediment cores were imaged using a Computer-Aided Tomography (CT) scanner at Massachusetts General Hospital, Boston, Massachusetts, United States. Procedures were developed, using the attenuation of X-rays, to differentiate between sediment and the water contained in macrobenthic...
Diagnosing Appendicitis: Evidence-Based Review of the Diagnostic Approach in 2014
Shogilev, Daniel J.; Duus, Nicolaj; Odom, Stephen R.; Shapiro, Nathan I.
2014-01-01
Introduction Acute appendicitis is the most common abdominal emergency requiring emergency surgery. However, the diagnosis is often challenging and the decision to operate, observe or further work-up a patient is often unclear. The utility of clinical scoring systems (namely the Alvarado score), laboratory markers, and the development of novel markers in the diagnosis of appendicitis remains controversial. This article presents an update on the diagnostic approach to appendicitis through an evidence-based review. Methods We performed a broad Medline search of radiological imaging, the Alvarado score, common laboratory markers, and novel markers in patients with suspected appendicitis. Results Computed tomography (CT) is the most accurate mode of imaging for suspected cases of appendicitis, but the associated increase in radiation exposure is problematic. The Alvarado score is a clinical scoring system that is used to predict the likelihood of appendicitis based on signs, symptoms and laboratory data. It can help risk stratify patients with suspected appendicitis and potentially decrease the use of CT imaging in patients with certain Alvarado scores. White blood cell (WBC), C-reactive protein (CRP), granulocyte count and proportion of polymorphonuclear (PMN) cells are frequently elevated in patients with appendicitis, but are insufficient on their own as a diagnostic modality. When multiple markers are used in combination their diagnostic utility is greatly increased. Several novel markers have been proposed to aid in the diagnosis of appendicitis; however, while promising, most are only in the preliminary stages of being studied. Conclusion While CT is the most accurate mode of imaging in suspected appendicitis, the accompanying radiation is a concern. Ultrasound may help in the diagnosis while decreasing the need for CT in certain circumstances. The Alvarado Score has good diagnostic utility at specific cutoff points. Laboratory markers have very limited diagnostic utility on their own but show promise when used in combination. Further studies are warranted for laboratory markers in combination and to validate potential novel markers. PMID:25493136
New diagnostics for melanoma detection: from artificial intelligence to RNA microarrays.
Ahlgrimm-Siess, Verena; Laimer, Martin; Arzberger, Edith; Hofmann-Wellenhof, Rainer
2012-07-01
Early detection of melanoma remains crucial to ensuring a favorable prognosis. Dermoscopy and total body photography are well-established noninvasive aids that increase the diagnostic accuracy of dermatologists in their daily routine, beyond that of a naked-eye examination. New noninvasive diagnostic techniques, such as reflectance confocal microscopy, multispectral digital imaging and RNA microarrays, are currently being investigated to determine their utility for melanoma detection. This review presents emerging technologies for noninvasive melanoma diagnosis, and discusses their advantages and limitations.
K, Jalal Deen; R, Ganesan; A, Merline
2017-07-27
Objective: Accurate segmentation of abnormal and healthy lungs is very crucial for a steadfast computer-aided disease diagnostics. Methods: For this purpose a stack of chest CT scans are processed. In this paper, novel methods are proposed for segmentation of the multimodal grayscale lung CT scan. In the conventional methods using Markov–Gibbs Random Field (MGRF) model the required regions of interest (ROI) are identified. Result: The results of proposed FCM and CNN based process are compared with the results obtained from the conventional method using MGRF model. The results illustrate that the proposed method can able to segment the various kinds of complex multimodal medical images precisely. Conclusion: However, in this paper, to obtain an exact boundary of the regions, every empirical dispersion of the image is computed by Fuzzy C-Means Clustering segmentation. A classification process based on the Convolutional Neural Network (CNN) classifier is accomplished to distinguish the normal tissue and the abnormal tissue. The experimental evaluation is done using the Interstitial Lung Disease (ILD) database. Creative Commons Attribution License
K, Jalal Deen; R, Ganesan; A, Merline
2017-01-01
Objective: Accurate segmentation of abnormal and healthy lungs is very crucial for a steadfast computer-aided disease diagnostics. Methods: For this purpose a stack of chest CT scans are processed. In this paper, novel methods are proposed for segmentation of the multimodal grayscale lung CT scan. In the conventional methods using Markov–Gibbs Random Field (MGRF) model the required regions of interest (ROI) are identified. Result: The results of proposed FCM and CNN based process are compared with the results obtained from the conventional method using MGRF model. The results illustrate that the proposed method can able to segment the various kinds of complex multimodal medical images precisely. Conclusion: However, in this paper, to obtain an exact boundary of the regions, every empirical dispersion of the image is computed by Fuzzy C-Means Clustering segmentation. A classification process based on the Convolutional Neural Network (CNN) classifier is accomplished to distinguish the normal tissue and the abnormal tissue. The experimental evaluation is done using the Interstitial Lung Disease (ILD) database. PMID:28749127
The incidence of coronary anomalies on routine coronary computed tomography scans
Karabay, Kanber Ocal; Yildiz, Abdulmelik; Bagirtan, Bayram; Geceer, Gurkan; Uysal, Ender
2013-01-01
Summary Objective This study aimed to assess the incidence of coronary anomalies using 64-multi-slice coronary computed tomography (MSCT). Methods The diagnostic MSCT scans of 745 consecutive patients were reviewed. Results The incidence of coronary anomalies was 4.96%. The detected coronary anomalies included the conus artery originating separately from the right coronary sinus (RCS) (n = 8, 1.07%), absence of the left main artery (n = 7, 0.93%), a superior right coronary artery (RCA) (n = 7, 0.93%), the circumflex artery (CFX) arising from the RCS (n = 4, 0.53%), the CFX originating from the RCA (n = 2, 0.26%), a posterior RCA (n = 1, 0.13%), a coronary fistula from the left anterior descending artery and RCA to the pulmonary artery (n = 1, 0.13%), and a coronary aneurysm (n = 1, 0.13%). Conclusions This study indicated that MSCT can be used to detect common coronary anomalies, and shows it has the potential to aid cardiologists and cardiac surgeons by revealing the origin and course of the coronary vessels. PMID:24042853
NASA Astrophysics Data System (ADS)
Bazant-Hegemark, F.; Stone, N.; Read, M. D.; McCarthy, K.; Wang, R. K.
2007-07-01
The keyword for management of cervical cancer is prevention. The present program within the UK, the 'National Health Service (NHS) cervical screening programme' (NHSCSP), is based on cytology. Although the program has reduced the incidence of cervical cancer, this program requires patient follow ups and relies on diagnostic biopsying. There is potential for reducing costs and workload within the NHS, and relieving anxiety of patients. In this study, Optical Coherence Tomography (OCT) was investigated for its capability to improve this situation. Our time domain bench top system used a superluminescent diode (Superlum), centre wave length ~1.3 μm, resolution (air) ~15 μm. Tissue samples were obtained according to the ethics approval by Gloucestershire LREC, Nr. 05/Q2005/123. 1387 images of 199 participants have been compared with histopathology results and categorized accordingly. Our OCT images do not reach the clarity and resolution of histopathology. Further, establishing and recognizing features of diagnostic significance seems difficult. Automated classification would allow one to take decision-making to move from the subjective appraisal of a physician to an objective assessment. Hence we investigated a classification algorithm for its ability in recognizing pre-cancerous stages from OCT images. The initial results show promise.
[Usefulness of imaging examinations in preoperative diagnosis of acute appendicitis].
Nitoń, Tomasz; Górecka-Nitoń, Aleksandra
2014-01-01
Acute appendicitis (AA) is the cause one of most operations perform in department of general surgery on emergency ward. Frequency of acute appendicitis range from 6-8% of population. Clinical presentation is frequently unspecified and despite common occurence leads to many difficulties in diagnosis. Diagnosis of acute appendicitis includes clinical examination, laboratory tests, diagnostic scoring systems, computer programs as physisian aids and imaging examinations. About 30-45% patients suspected of acute appendicitis have untypical clinical presentation and here use of US or CT is very helpful. Longstanding use of US resulted in high AA evaluation accuracy with high sensitivity (75-90%) and specificity (84-100%). CT demonstrates above 95% ratio of correct diagnoses, reduces negative appendectomy rates and perforation rates as well as unnecessary observations. CT sensitivity and specificity CT is estimated between 83-100% among different authors. Expedited AA diagnosis, surgery and reduced hospitalization time are possible advantages of imaging tests. Additionally these tests can detect alternative deseases imitating acute appnedicitis. Use of imaging tests especially CT is beneficial in fertile women because of frequent genito-urinary disorders leading to the most diagnostic errors. However thera are contraindications in use of CT, for example it can not be performed in early pregnancy etc...
Del Rosario, Francis; Farahi, Jessica M; Drendel, Jesse; Buntinx-Krieg, Talayesa; Caravaglio, Joseph; Domozych, Renee; Chapman, Stephanie; Braunberger, Taylor; Dellavalle, Robert P; Norris, David A; Fathi, Ramin; Alkousakis, Theodore
2018-05-01
Digital dermoscopic image analysis of pigmented skin lesions (PSLs) has become increasingly popular, despite its unclear clinical utility. Unbiased, high-powered studies investigating the efficacy of commercially available systems are limited. To investigate the diagnostic performance of the FotoFinder Mole-Analyzer in assessing PSLs for cutaneous melanoma. In this 15-year retrospective study, the histopathologies of 1076 biopsied PSLs among a total of 2500 imaged PSLs were collected. The biopsied PSLs were categorized as benign or malignant (cutaneous melanoma) based on histopathology. Analyzer scores (0-1.00) for these PSLs were obtained and grouped according to histopathology. At an optimized cutoff score of 0.50, a sensitivity of 56% and a specificity of 74% were achieved. The area under the receiver operating characteristics curve was 0.698, indicating poor accuracy as a diagnostic tool. This study had a retrospective design and involved only a single institution. Our study reveals a low sensitivity of the scoring function of this digital dermoscopic image analyzer for detecting cutaneous melanomas. Physicians must apply keen clinical judgment when using such devices in the screening of suspicious PSLs. Copyright © 2017 American Academy of Dermatology, Inc. All rights reserved.
Discriminative power of visual attributes in dermatology.
Giotis, Ioannis; Visser, Margaretha; Jonkman, Marcel; Petkov, Nicolai
2013-02-01
Visual characteristics such as color and shape of skin lesions play an important role in the diagnostic process. In this contribution, we quantify the discriminative power of such attributes using an information theoretical approach. We estimate the probability of occurrence of each attribute as a function of the skin diseases. We use the distribution of this probability across the studied diseases and its entropy to define the discriminative power of the attribute. The discriminative power has a maximum value for attributes that occur (or do not occur) for only one disease and a minimum value for those which are equally likely to be observed among all diseases. Verrucous surface, red and brown colors, and the presence of more than 10 lesions are among the most informative attributes. A ranking of attributes is also carried out and used together with a naive Bayesian classifier, yielding results that confirm the soundness of the proposed method. proposed measure is proven to be a reliable way of assessing the discriminative power of dermatological attributes, and it also helps generate a condensed dermatological lexicon. Therefore, it can be of added value to the manual or computer-aided diagnostic process. © 2012 John Wiley & Sons A/S.
Recurrent severe abdominal pain in the pediatric patient.
Homme, James L; Foster, Ashley A
2014-05-01
Ureteropelvic junction obstruction (UPJO) is a blockage occurring at the junction of the ureter and the renal pelvis. Pediatric patients with UPJO pose a diagnostic challenge when they present to the emergency department (ED) with severe recurrent abdominal pain if there is not a level of suspicion for this condition. Our aim was to review presentation of UPJO to the ED, methods of diagnosis, and treatment of this common but often overlooked condition. We report on 2 patients, a 9-year-old and 3-year-old, who had multiple presentations to health care providers and the ED with intermittent and recurrent abdominal pain. Subsequent testing, including ultrasound (US) and computed tomography (CT) with diuretic-recreated symptoms, revealed UPJO. Open pyeloplasty was performed, resulting in complete resolution of symptoms. UPJO is an important diagnosis to consider when patients present to the ED with recurrent abdominal pain. US can be helpful in suspecting the diagnosis, but often CT, magnetic resonance urography, or diuretic scintigraphy is required for confirmation. Diuretics can be used to aid diagnostic testing by reproducing abdominal pain at the time of imaging. Referral to a urologist for open pyeloplasty is definitive treatment for this condition. Copyright © 2014 Elsevier Inc. All rights reserved.
A soft kinetic data structure for lesion border detection.
Kockara, Sinan; Mete, Mutlu; Yip, Vincent; Lee, Brendan; Aydin, Kemal
2010-06-15
The medical imaging and image processing techniques, ranging from microscopic to macroscopic, has become one of the main components of diagnostic procedures to assist dermatologists in their medical decision-making processes. Computer-aided segmentation and border detection on dermoscopic images is one of the core components of diagnostic procedures and therapeutic interventions for skin cancer. Automated assessment tools for dermoscopic images have become an important research field mainly because of inter- and intra-observer variations in human interpretations. In this study, a novel approach-graph spanner-for automatic border detection in dermoscopic images is proposed. In this approach, a proximity graph representation of dermoscopic images in order to detect regions and borders in skin lesion is presented. Graph spanner approach is examined on a set of 100 dermoscopic images whose manually drawn borders by a dermatologist are used as the ground truth. Error rates, false positives and false negatives along with true positives and true negatives are quantified by digitally comparing results with manually determined borders from a dermatologist. The results show that the highest precision and recall rates obtained to determine lesion boundaries are 100%. However, accuracy of assessment averages out at 97.72% and borders errors' mean is 2.28% for whole dataset.
Some Workplace Effects of CAD and CAM.
ERIC Educational Resources Information Center
Ebel, Karl-H.; Ulrich, Erhard
1987-01-01
Examines the impact of computer-aided design (CAD) and computer-aided manufacturing (CAM) on employment, work organization, working conditions, job content, training, and industrial relations in several countries. Finds little evidence of negative employment effects since productivity gains are offset by various compensatory factors. (Author/CH)
Society for College Science Teachers: High Technology.
ERIC Educational Resources Information Center
Menefee, Robert
1983-01-01
Presents findings of a study group on high technology charged with determining a definition, assessing current educational response, and examining implications for the future. Topics addressed include: super-techs; computer-aided design/computer-aided manufacture (CAD/CAM); structural unemployment; a two-plus-two curriculum; and educational…
The Power of Computer-aided Tomography to Investigate Marine Benthic Communities
Utilization of Computer-aided-Tomography (CT) technology is a powerful tool to investigate benthic communities in aquatic systems. In this presentation, we will attempt to summarize our 15 years of experience in developing specific CT methods and applications to marine benthic co...
DOT National Transportation Integrated Search
1989-01-01
Future levels of air traffic control automation plan to incorporate computer aiding features designed to alert the controller to upcoming problem situations by displaying information that will identify the situation and suggest possible solutions. Co...
A Simple and Resource-efficient Setup for the Computer-aided Drug Design Laboratory.
Moretti, Loris; Sartori, Luca
2016-10-01
Undertaking modelling investigations for Computer-Aided Drug Design (CADD) requires a proper environment. In principle, this could be done on a single computer, but the reality of a drug discovery program requires robustness and high-throughput computing (HTC) to efficiently support the research. Therefore, a more capable alternative is needed but its implementation has no widespread solution. Here, the realization of such a computing facility is discussed, from general layout to technical details all aspects are covered. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.